Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:37

Tabular Output Report in Format: HTML

Building: High-Rise Apartment

Environment: Albuquerque Intl Sunport NM USA TMY3 WMO#=723650

Simulation Timestamp: 2018-10-19 09:40:08


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 4274.69 545.49 605.49
Net Site Energy 4274.69 545.49 605.49
Total Source Energy 11052.84 1410.43 1565.58
Net Source Energy 11052.84 1410.43 1565.58


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 7836.48
Net Conditioned Building Area 7059.89
Unconditioned Building Area 776.58


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 39.47 85.75 0.00 0.00 0.00 0.00
Cooling 543.05 0.00 0.00 0.00 0.00 0.00
Interior Lighting 416.41 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 168.44 0.00 0.00 0.00 0.00 0.00
Interior Equipment 1131.09 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 699.65 0.00 0.00 0.00 0.00 0.00
Pumps 43.59 0.00 0.00 0.00 0.00 0.00
Heat Rejection 19.13 0.00 0.00 0.00 0.00 1823.67
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 1107.29 0.00 0.00 0.00 4778.51
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 3081.65 1193.04 0.00 0.00 0.00 6602.18
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating Boiler 0.00 85.75 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
  Other 39.47 0.00 0.00 0.00 0.00 0.00
Cooling General 543.05 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 348.50 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 67.92 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 168.44 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 1131.09 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 699.65 0.00 0.00 0.00 0.00 0.00
Pumps General 43.59 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 19.13 0.00 0.00 0.00 0.00 1823.67
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 1107.29 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 4778.51
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 82.84 0.00 0.00 0.00 0.00 0.00
HVAC 190.50 168.99 0.00 0.00 0.00 0.94
Other 160.21 0.00 0.00 0.00 0.00 0.00
Total 436.50 168.99 0.00 0.00 0.00 0.94


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 74.63 0.00 0.00 0.00 0.00 0.00
HVAC 171.62 152.24 0.00 0.00 0.00 0.84
Other 144.34 0.00 0.00 0.00 0.00 0.00
Total 393.24 152.24 0.00 0.00 0.00 0.84


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 3081.65 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 3081.65 100.00
     
Total On-Site and Utility Electric Sources 3081.65 100.00
Total Electricity End Uses 3081.65 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 6602.18 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 6602.18 100.00
Total Water End Uses 6602.18 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 83.00
Time Setpoint Not Met During Occupied Cooling 592.00
Time Not Comfortable Based on Simple ASHRAE 55-2004 1030.25


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |

COMPONENTS OF PEAK ELECTRICAL DEMAND

| Meter |

COMPONENTS OF PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:37
RunPeriod Albuquerque Intl Sunport NM USA TMY3 WMO#=723650
Weather File Albuquerque Intl Sunport NM USA TMY3 WMO#=723650
Latitude [deg] 35.04
Longitude [deg] -106.6
Elevation [m] 1619.00
Time Zone -7.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3855.02 1411.96 515.55 1411.96 515.55
Window Opening Area [m2] 1150.39 423.59 152.73 423.59 150.48
Window-Wall Ratio [%] 29.84 30.00 29.62 30.00 29.19


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3752.84 1411.96 464.46 1411.96 464.46
Window Opening Area [m2] 1125.85 423.59 139.34 423.59 139.34
Window-Wall Ratio [%] 30.00 30.00 30.00 30.00 30.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
OFFICE 88.25 Yes Yes 268.96 1.00 58.52 17.56 23.8959 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 4.47 8.5250   0.0000
F2 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F2 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F2 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F2 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F2 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F2 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F2 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F2 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F2 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   0.0000
F3 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F3 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F3 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F3 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F3 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F3 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F3 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F3 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F3 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   0.0000
F4 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F4 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F4 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F4 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F4 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F4 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F4 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F4 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F4 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   0.0000
M SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
M CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 17.0500   0.0000
F6 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F6 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F6 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F6 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F6 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F6 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F6 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F6 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F6 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   0.0000
F7 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F7 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F7 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F7 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F7 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F7 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F7 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F7 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F7 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   0.0000
F8 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F8 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F8 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F8 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F8 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F8 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F8 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F8 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F8 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   0.0000
F9 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F9 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F9 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F9 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F9 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F9 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F9 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F9 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F9 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   0.0000
T SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   263.6661
Total 7836.48     23884.04   3855.02 1150.39 14.0302 39.48 8.6219
Conditioned Total 7059.89     21517.16   3752.84 1125.85 14.5420 35.57 6.6700
Unconditioned Total 776.58     2366.87   102.18 24.54 9.3775   26.3666
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 21-JUL-19:15 17-JAN-07:00 - - - 21-JUL-17:15
Heating 0.00 87410.18 0.00 0.00 0.00 0.00
Cooling 59469.48 0.00 0.00 0.00 0.00 0.00
Interior Lighting 25049.15 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 10720.10 0.00 0.00 0.00 0.00 0.00
Interior Equipment 49704.83 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 22185.69 0.00 0.00 0.00 0.00 0.00
Pumps 1393.03 0.00 0.00 0.00 0.00 0.00
Heat Rejection 1879.51 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 86775.67 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 171347.37 174185.85 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating Boiler 0.00 87410.18 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 59469.48 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 20603.34 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 4445.81 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 10720.10 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 49704.83 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 22185.69 0.00 0.00 0.00 0.00 0.00
Pumps General 1393.03 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 1879.51 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 86775.67 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 125.00 92.95 0.00 0.00 0.00
Cooling 1719.83 0.00 0.00 0.00 0.00
Interior Lighting 1318.78 0.00 0.00 0.00 0.00
Exterior Lighting 533.44 0.00 0.00 0.00 0.00
Interior Equipment 3582.17 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 2215.79 0.00 0.00 0.00 0.00
Pumps 138.04 0.00 0.00 0.00 0.00
Heat Rejection 60.59 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 1200.30 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 9759.58 1293.26 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 17.71 13.17 0.00 0.00 0.00
Cooling 243.61 0.00 0.00 0.00 0.00
Interior Lighting 186.80 0.00 0.00 0.00 0.00
Exterior Lighting 75.56 0.00 0.00 0.00 0.00
Interior Equipment 507.40 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 313.86 0.00 0.00 0.00 0.00
Pumps 19.55 0.00 0.00 0.00 0.00
Heat Rejection 8.58 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 170.02 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1382.40 183.18 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 17.71 13.17 0.00 0.00 0.00
Cooling 243.61 0.00 0.00 0.00 0.00
Interior Lighting 186.80 0.00 0.00 0.00 0.00
Exterior Lighting 75.56 0.00 0.00 0.00 0.00
Interior Equipment 507.40 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 313.86 0.00 0.00 0.00 0.00
Pumps 19.55 0.00 0.00 0.00 0.00
Heat Rejection 8.58 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 170.02 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1382.40 183.18 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB -7.90 0.00 -7.90 Wetbulb [C] 3.20 0.00
ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 35.10 13.50 15.70 Wetbulb [C] 4.40 220.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 270.00 180.00  
F2 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F2 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F2 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F2 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F2 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F2 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F3 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F3 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F3 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F3 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F3 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F3 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F4 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F4 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F4 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F4 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F4 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F4 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
M WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F6 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F6 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F6 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F6 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F6 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F6 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F7 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F7 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F7 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F7 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F7 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F7 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F8 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F8 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F8 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F8 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F8 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F8 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F9 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F9 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F9 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F9 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F9 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F9 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.30 0.269 0.283 77.66 0.00 0.00  


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW3 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL SWA 180.00 90.00 S
GWINDOW2 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G WWALL SWA 270.00 90.00 W
GWINDOW4 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL NWA 0.00 90.00 N
GWINDOW6 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G WWALL NWA 270.00 90.00 W
GWINDOW1 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL SEA 180.00 90.00 S
GWINDOW8 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G EWALL SEA 90.00 90.00 E
GWINDOW5 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL NEA 0.00 90.00 N
GWINDOW7 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G EWALL NEA 90.00 90.00 E
GWINDOW9 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL N1A 0.00 90.00 N
GWINDOW10 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL N2A 0.00 90.00 N
GWINDOW11 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL S1A 180.00 90.00 S
GWINDOW12 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL S2A 180.00 90.00 S
GWINDOW13 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No G WWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.52_SHGC_0.40 3.36 0.00 0.00 3.36 3.36 2.653 0.426 0.308     No G EWALL C 90.00 90.00 E
F2WINDOW2 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 WWALL SWA 270.00 90.00 W
F2WINDOW3 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL SWA 180.00 90.00 S
F2WINDOW4 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL NWA 0.00 90.00 N
F2WINDOW6 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 WWALL NWA 270.00 90.00 W
F2WINDOW8 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 EWALL SEA 90.00 90.00 E
F2WINDOW1 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL SEA 180.00 90.00 S
F2WINDOW5 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL NEA 0.00 90.00 N
F2WINDOW7 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 EWALL NEA 90.00 90.00 E
F2WINDOW9 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL N1A 0.00 90.00 N
F2WINDOW10 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL N2A 0.00 90.00 N
F2WINDOW11 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL S1A 180.00 90.00 S
F2WINDOW12 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL S2A 180.00 90.00 S
F2WINDOW13 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F2 WWALL C 270.00 90.00 W
F2WINDOW14 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F2 EWALL C 90.00 90.00 E
F3WINDOW2 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 WWALL SWA 270.00 90.00 W
F3WINDOW3 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL SWA 180.00 90.00 S
F3WINDOW4 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL NWA 0.00 90.00 N
F3WINDOW6 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 WWALL NWA 270.00 90.00 W
F3WINDOW8 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 EWALL SEA 90.00 90.00 E
F3WINDOW1 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL SEA 180.00 90.00 S
F3WINDOW5 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL NEA 0.00 90.00 N
F3WINDOW7 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 EWALL NEA 90.00 90.00 E
F3WINDOW9 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL N1A 0.00 90.00 N
F3WINDOW10 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL N2A 0.00 90.00 N
F3WINDOW11 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL S1A 180.00 90.00 S
F3WINDOW12 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL S2A 180.00 90.00 S
F3WINDOW13 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F3 WWALL C 270.00 90.00 W
F3WINDOW14 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F3 EWALL C 90.00 90.00 E
F4WINDOW2 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 WWALL SWA 270.00 90.00 W
F4WINDOW3 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL SWA 180.00 90.00 S
F4WINDOW4 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL NWA 0.00 90.00 N
F4WINDOW6 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 WWALL NWA 270.00 90.00 W
F4WINDOW8 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 EWALL SEA 90.00 90.00 E
F4WINDOW1 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL SEA 180.00 90.00 S
F4WINDOW5 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL NEA 0.00 90.00 N
F4WINDOW7 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 EWALL NEA 90.00 90.00 E
F4WINDOW9 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL N1A 0.00 90.00 N
F4WINDOW10 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL N2A 0.00 90.00 N
F4WINDOW11 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL S1A 180.00 90.00 S
F4WINDOW12 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL S2A 180.00 90.00 S
F4WINDOW13 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F4 WWALL C 270.00 90.00 W
F4WINDOW14 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F4 EWALL C 90.00 90.00 E
MWINDOW2 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M WWALL SWA 270.00 90.00 W
MWINDOW3 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL SWA 180.00 90.00 S
MWINDOW4 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL NWA 0.00 90.00 N
MWINDOW6 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M WWALL NWA 270.00 90.00 W
MWINDOW8 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M EWALL SEA 90.00 90.00 E
MWINDOW1 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL SEA 180.00 90.00 S
MWINDOW5 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL NEA 0.00 90.00 N
MWINDOW7 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M EWALL NEA 90.00 90.00 E
MWINDOW9 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL N1A 0.00 90.00 N
MWINDOW10 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL N2A 0.00 90.00 N
MWINDOW11 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL S1A 180.00 90.00 S
MWINDOW12 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL S2A 180.00 90.00 S
MWINDOW13 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No M WWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No M EWALL C 90.00 90.00 E
F6WINDOW2 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 WWALL SWA 270.00 90.00 W
F6WINDOW3 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL SWA 180.00 90.00 S
F6WINDOW4 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL NWA 0.00 90.00 N
F6WINDOW6 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 WWALL NWA 270.00 90.00 W
F6WINDOW8 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 EWALL SEA 90.00 90.00 E
F6WINDOW1 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL SEA 180.00 90.00 S
F6WINDOW5 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL NEA 0.00 90.00 N
F6WINDOW7 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 EWALL NEA 90.00 90.00 E
F6WINDOW9 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL N1A 0.00 90.00 N
F6WINDOW10 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL N2A 0.00 90.00 N
F6WINDOW11 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL S1A 180.00 90.00 S
F6WINDOW12 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL S2A 180.00 90.00 S
F6WINDOW13 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F6 WWALL C 270.00 90.00 W
F6WINDOW14 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F6 EWALL C 90.00 90.00 E
F7WINDOW2 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 WWALL SWA 270.00 90.00 W
F7WINDOW3 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL SWA 180.00 90.00 S
F7WINDOW4 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL NWA 0.00 90.00 N
F7WINDOW6 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 WWALL NWA 270.00 90.00 W
F7WINDOW8 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 EWALL SEA 90.00 90.00 E
F7WINDOW1 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL SEA 180.00 90.00 S
F7WINDOW5 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL NEA 0.00 90.00 N
F7WINDOW7 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 EWALL NEA 90.00 90.00 E
F7WINDOW9 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL N1A 0.00 90.00 N
F7WINDOW10 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL N2A 0.00 90.00 N
F7WINDOW11 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL S1A 180.00 90.00 S
F7WINDOW12 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL S2A 180.00 90.00 S
F7WINDOW13 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F7 WWALL C 270.00 90.00 W
F7WINDOW14 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F7 EWALL C 90.00 90.00 E
F8WINDOW2 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 WWALL SWA 270.00 90.00 W
F8WINDOW3 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL SWA 180.00 90.00 S
F8WINDOW4 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL NWA 0.00 90.00 N
F8WINDOW6 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 WWALL NWA 270.00 90.00 W
F8WINDOW8 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 EWALL SEA 90.00 90.00 E
F8WINDOW1 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL SEA 180.00 90.00 S
F8WINDOW5 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL NEA 0.00 90.00 N
F8WINDOW7 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 EWALL NEA 90.00 90.00 E
F8WINDOW9 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL N1A 0.00 90.00 N
F8WINDOW10 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL N2A 0.00 90.00 N
F8WINDOW11 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL S1A 180.00 90.00 S
F8WINDOW12 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL S2A 180.00 90.00 S
F8WINDOW13 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F8 WWALL C 270.00 90.00 W
F8WINDOW14 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F8 EWALL C 90.00 90.00 E
F9WINDOW2 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 WWALL SWA 270.00 90.00 W
F9WINDOW3 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL SWA 180.00 90.00 S
F9WINDOW4 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL NWA 0.00 90.00 N
F9WINDOW6 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 WWALL NWA 270.00 90.00 W
F9WINDOW8 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 EWALL SEA 90.00 90.00 E
F9WINDOW1 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL SEA 180.00 90.00 S
F9WINDOW5 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL NEA 0.00 90.00 N
F9WINDOW7 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 EWALL NEA 90.00 90.00 E
F9WINDOW9 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL N1A 0.00 90.00 N
F9WINDOW10 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL N2A 0.00 90.00 N
F9WINDOW11 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL S1A 180.00 90.00 S
F9WINDOW12 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL S2A 180.00 90.00 S
F9WINDOW13 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F9 WWALL C 270.00 90.00 W
F9WINDOW14 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F9 EWALL C 90.00 90.00 E
TWINDOW2 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T WWALL SWA 270.00 90.00 W
TWINDOW3 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL SWA 180.00 90.00 S
TWINDOW4 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL NWA 0.00 90.00 N
TWINDOW6 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T WWALL NWA 270.00 90.00 W
TWINDOW8 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T EWALL SEA 90.00 90.00 E
TWINDOW1 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL SEA 180.00 90.00 S
TWINDOW5 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL NEA 0.00 90.00 N
TWINDOW7 WINDOW_U_0.52_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T EWALL NEA 90.00 90.00 E
TWINDOW9 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL N1A 0.00 90.00 N
TWINDOW10 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL N2A 0.00 90.00 N
TWINDOW11 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL S1A 180.00 90.00 S
TWINDOW12 WINDOW_U_0.52_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL S2A 180.00 90.00 S
TWINDOW13 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No T WWALL C 270.00 90.00 W
TWINDOW14 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No T EWALL C 90.00 90.00 E
Total or Average           1150.39 2.653 0.426 0.308              
North Total or Average           423.59 2.653 0.426 0.308              
Non-North Total or Average           726.80 2.653 0.426 0.308              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
GWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
GWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
GWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
GWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F2WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F2WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F2WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F2WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F2WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F2WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F3WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F3WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F3WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F3WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F3WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F3WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F4WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F4WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F4WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F4WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F4WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F4WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
MWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
MWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
MWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
MWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
MWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F6WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F6WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F6WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F6WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F6WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F6WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F7WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F7WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F7WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F7WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F7WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F7WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F8WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F8WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F8WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F8WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F8WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F8WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F9WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F9WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F9WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F9WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F9WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F9WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
TWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
TWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
TWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
TWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
TWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
G SW APARTMENT_LIGHTS_HARDWIRED G SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
G NW APARTMENT_LIGHTS_HARDWIRED G NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
OFFICE_LIGHTS_HARDWIRED OFFICE 11.9479 88.25 1054.39 GeneralLights LTG_OFF_SCH 56.26 168.00 55.46 0.0000 Y 10.98
G NE APARTMENT_LIGHTS_HARDWIRED G NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
G N1 APARTMENT_LIGHTS_HARDWIRED G N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
G N2 APARTMENT_LIGHTS_HARDWIRED G N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
G S1 APARTMENT_LIGHTS_HARDWIRED G S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
G S2 APARTMENT_LIGHTS_HARDWIRED G S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
G CORRIDOR_LIGHTS_HARDWIRED G CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F2 SW APARTMENT_LIGHTS_HARDWIRED F2 SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 NW APARTMENT_LIGHTS_HARDWIRED F2 NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 SE APARTMENT_LIGHTS_HARDWIRED F2 SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 NE APARTMENT_LIGHTS_HARDWIRED F2 NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 N1 APARTMENT_LIGHTS_HARDWIRED F2 N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 N2 APARTMENT_LIGHTS_HARDWIRED F2 N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 S1 APARTMENT_LIGHTS_HARDWIRED F2 S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 S2 APARTMENT_LIGHTS_HARDWIRED F2 S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 CORRIDOR_LIGHTS_HARDWIRED F2 CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F3 SW APARTMENT_LIGHTS_HARDWIRED F3 SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 NW APARTMENT_LIGHTS_HARDWIRED F3 NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 SE APARTMENT_LIGHTS_HARDWIRED F3 SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 NE APARTMENT_LIGHTS_HARDWIRED F3 NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 N1 APARTMENT_LIGHTS_HARDWIRED F3 N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 N2 APARTMENT_LIGHTS_HARDWIRED F3 N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 S1 APARTMENT_LIGHTS_HARDWIRED F3 S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 S2 APARTMENT_LIGHTS_HARDWIRED F3 S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 CORRIDOR_LIGHTS_HARDWIRED F3 CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F4 SW APARTMENT_LIGHTS_HARDWIRED F4 SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 NW APARTMENT_LIGHTS_HARDWIRED F4 NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 SE APARTMENT_LIGHTS_HARDWIRED F4 SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 NE APARTMENT_LIGHTS_HARDWIRED F4 NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 N1 APARTMENT_LIGHTS_HARDWIRED F4 N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 N2 APARTMENT_LIGHTS_HARDWIRED F4 N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 S1 APARTMENT_LIGHTS_HARDWIRED F4 S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 S2 APARTMENT_LIGHTS_HARDWIRED F4 S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 CORRIDOR_LIGHTS_HARDWIRED F4 CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
M SW APARTMENT_LIGHTS_HARDWIRED M SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M NW APARTMENT_LIGHTS_HARDWIRED M NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M SE APARTMENT_LIGHTS_HARDWIRED M SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M NE APARTMENT_LIGHTS_HARDWIRED M NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M N1 APARTMENT_LIGHTS_HARDWIRED M N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M N2 APARTMENT_LIGHTS_HARDWIRED M N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M S1 APARTMENT_LIGHTS_HARDWIRED M S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M S2 APARTMENT_LIGHTS_HARDWIRED M S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M CORRIDOR_LIGHTS_HARDWIRED M CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F6 SW APARTMENT_LIGHTS_HARDWIRED F6 SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 NW APARTMENT_LIGHTS_HARDWIRED F6 NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 SE APARTMENT_LIGHTS_HARDWIRED F6 SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 NE APARTMENT_LIGHTS_HARDWIRED F6 NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 N1 APARTMENT_LIGHTS_HARDWIRED F6 N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 N2 APARTMENT_LIGHTS_HARDWIRED F6 N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 S1 APARTMENT_LIGHTS_HARDWIRED F6 S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 S2 APARTMENT_LIGHTS_HARDWIRED F6 S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 CORRIDOR_LIGHTS_HARDWIRED F6 CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F7 SW APARTMENT_LIGHTS_HARDWIRED F7 SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 NW APARTMENT_LIGHTS_HARDWIRED F7 NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 SE APARTMENT_LIGHTS_HARDWIRED F7 SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 NE APARTMENT_LIGHTS_HARDWIRED F7 NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 N1 APARTMENT_LIGHTS_HARDWIRED F7 N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 N2 APARTMENT_LIGHTS_HARDWIRED F7 N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 S1 APARTMENT_LIGHTS_HARDWIRED F7 S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 S2 APARTMENT_LIGHTS_HARDWIRED F7 S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 CORRIDOR_LIGHTS_HARDWIRED F7 CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F8 SW APARTMENT_LIGHTS_HARDWIRED F8 SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 NW APARTMENT_LIGHTS_HARDWIRED F8 NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 SE APARTMENT_LIGHTS_HARDWIRED F8 SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 NE APARTMENT_LIGHTS_HARDWIRED F8 NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 N1 APARTMENT_LIGHTS_HARDWIRED F8 N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 N2 APARTMENT_LIGHTS_HARDWIRED F8 N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 S1 APARTMENT_LIGHTS_HARDWIRED F8 S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 S2 APARTMENT_LIGHTS_HARDWIRED F8 S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 CORRIDOR_LIGHTS_HARDWIRED F8 CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F9 SW APARTMENT_LIGHTS_HARDWIRED F9 SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 NW APARTMENT_LIGHTS_HARDWIRED F9 NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 SE APARTMENT_LIGHTS_HARDWIRED F9 SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 NE APARTMENT_LIGHTS_HARDWIRED F9 NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 N1 APARTMENT_LIGHTS_HARDWIRED F9 N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 N2 APARTMENT_LIGHTS_HARDWIRED F9 N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 S1 APARTMENT_LIGHTS_HARDWIRED F9 S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 S2 APARTMENT_LIGHTS_HARDWIRED F9 S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 CORRIDOR_LIGHTS_HARDWIRED F9 CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
T SW APARTMENT_LIGHTS_HARDWIRED T SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T NW APARTMENT_LIGHTS_HARDWIRED T NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T SE APARTMENT_LIGHTS_HARDWIRED T SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T NE APARTMENT_LIGHTS_HARDWIRED T NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T N1 APARTMENT_LIGHTS_HARDWIRED T N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T N2 APARTMENT_LIGHTS_HARDWIRED T N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T S1 APARTMENT_LIGHTS_HARDWIRED T S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T S2 APARTMENT_LIGHTS_HARDWIRED T S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T CORRIDOR_LIGHTS_HARDWIRED T CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
G SW APARTMENT_LIGHTS_PLUGIN G SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
G NW APARTMENT_LIGHTS_PLUGIN G NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
OFFICE_LIGHTS_PLUGIN OFFICE 11.9479 88.25 1054.39 GeneralLights-plugin LTG_OFF_SCH 56.26 168.00 55.46 0.0000 Y 10.98
G NE APARTMENT_LIGHTS_PLUGIN G NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
G N1 APARTMENT_LIGHTS_PLUGIN G N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
G N2 APARTMENT_LIGHTS_PLUGIN G N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
G S1 APARTMENT_LIGHTS_PLUGIN G S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
G S2 APARTMENT_LIGHTS_PLUGIN G S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 SW APARTMENT_LIGHTS_PLUGIN F2 SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 NW APARTMENT_LIGHTS_PLUGIN F2 NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 SE APARTMENT_LIGHTS_PLUGIN F2 SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 NE APARTMENT_LIGHTS_PLUGIN F2 NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 N1 APARTMENT_LIGHTS_PLUGIN F2 N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 N2 APARTMENT_LIGHTS_PLUGIN F2 N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 S1 APARTMENT_LIGHTS_PLUGIN F2 S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 S2 APARTMENT_LIGHTS_PLUGIN F2 S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 SW APARTMENT_LIGHTS_PLUGIN F3 SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 NW APARTMENT_LIGHTS_PLUGIN F3 NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 SE APARTMENT_LIGHTS_PLUGIN F3 SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 NE APARTMENT_LIGHTS_PLUGIN F3 NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 N1 APARTMENT_LIGHTS_PLUGIN F3 N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 N2 APARTMENT_LIGHTS_PLUGIN F3 N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 S1 APARTMENT_LIGHTS_PLUGIN F3 S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 S2 APARTMENT_LIGHTS_PLUGIN F3 S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 SW APARTMENT_LIGHTS_PLUGIN F4 SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 NW APARTMENT_LIGHTS_PLUGIN F4 NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 SE APARTMENT_LIGHTS_PLUGIN F4 SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 NE APARTMENT_LIGHTS_PLUGIN F4 NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 N1 APARTMENT_LIGHTS_PLUGIN F4 N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 N2 APARTMENT_LIGHTS_PLUGIN F4 N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 S1 APARTMENT_LIGHTS_PLUGIN F4 S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 S2 APARTMENT_LIGHTS_PLUGIN F4 S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M SW APARTMENT_LIGHTS_PLUGIN M SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M NW APARTMENT_LIGHTS_PLUGIN M NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M SE APARTMENT_LIGHTS_PLUGIN M SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M NE APARTMENT_LIGHTS_PLUGIN M NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M N1 APARTMENT_LIGHTS_PLUGIN M N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M N2 APARTMENT_LIGHTS_PLUGIN M N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M S1 APARTMENT_LIGHTS_PLUGIN M S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M S2 APARTMENT_LIGHTS_PLUGIN M S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M CORRIDOR_LIGHTS_PLUGIN M CORRIDOR 8.5250 77.66 662.04 GeneralLights-plugin LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F6 SW APARTMENT_LIGHTS_PLUGIN F6 SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F6 NW APARTMENT_LIGHTS_PLUGIN F6 NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F6 SE APARTMENT_LIGHTS_PLUGIN F6 SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F6 NE APARTMENT_LIGHTS_PLUGIN F6 NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F6 N1 APARTMENT_LIGHTS_PLUGIN F6 N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F6 N2 APARTMENT_LIGHTS_PLUGIN F6 N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F6 S1 APARTMENT_LIGHTS_PLUGIN F6 S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F6 S2 APARTMENT_LIGHTS_PLUGIN F6 S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 SW APARTMENT_LIGHTS_PLUGIN F7 SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 NW APARTMENT_LIGHTS_PLUGIN F7 NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 SE APARTMENT_LIGHTS_PLUGIN F7 SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 NE APARTMENT_LIGHTS_PLUGIN F7 NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 N1 APARTMENT_LIGHTS_PLUGIN F7 N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 N2 APARTMENT_LIGHTS_PLUGIN F7 N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 S1 APARTMENT_LIGHTS_PLUGIN F7 S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 S2 APARTMENT_LIGHTS_PLUGIN F7 S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 SW APARTMENT_LIGHTS_PLUGIN F8 SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 NW APARTMENT_LIGHTS_PLUGIN F8 NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 SE APARTMENT_LIGHTS_PLUGIN F8 SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 NE APARTMENT_LIGHTS_PLUGIN F8 NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 N1 APARTMENT_LIGHTS_PLUGIN F8 N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 N2 APARTMENT_LIGHTS_PLUGIN F8 N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 S1 APARTMENT_LIGHTS_PLUGIN F8 S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 S2 APARTMENT_LIGHTS_PLUGIN F8 S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 SW APARTMENT_LIGHTS_PLUGIN F9 SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 NW APARTMENT_LIGHTS_PLUGIN F9 NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 SE APARTMENT_LIGHTS_PLUGIN F9 SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 NE APARTMENT_LIGHTS_PLUGIN F9 NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 N1 APARTMENT_LIGHTS_PLUGIN F9 N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 N2 APARTMENT_LIGHTS_PLUGIN F9 N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 S1 APARTMENT_LIGHTS_PLUGIN F9 S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 S2 APARTMENT_LIGHTS_PLUGIN F9 S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T SW APARTMENT_LIGHTS_PLUGIN T SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T NW APARTMENT_LIGHTS_PLUGIN T NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T SE APARTMENT_LIGHTS_PLUGIN T SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T NE APARTMENT_LIGHTS_PLUGIN T NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T N1 APARTMENT_LIGHTS_PLUGIN T N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T N2 APARTMENT_LIGHTS_PLUGIN T N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T S1 APARTMENT_LIGHTS_PLUGIN T S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T S2 APARTMENT_LIGHTS_PLUGIN T S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
Interior Lighting Total   7.3426 14974.03 109947.72               416.41


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 10720.10 AstronomicalClock -   83.70 83.70 168.44
Exterior Lighting Total 10720.10           168.44



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
CENTRAL BOILER Boiler:HotWater 244450.99 0.80    
CENTRAL TOWER EvaporativeFluidCooler:SingleSpeed 195560.79      


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
HEAT PUMP COOLING MODE AIRLOOP G SW Coil:Cooling:WaterToAirHeatPump:EquationFit   3205.74 2069.43 1136.32 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3148.90 2033.46 1115.44 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP OFFICE Coil:Cooling:WaterToAirHeatPump:EquationFit   4016.33 2614.97 1401.35 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2247.30 1476.51 770.79 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1649.01 1075.73 573.28 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1624.43 1060.20 564.23 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1773.44 1138.37 635.07 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1845.11 1184.20 660.92 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4097.56 2645.61 1451.95 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3998.19 2581.99 1416.20 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   3602.22 2322.51 1279.72 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2973.18 1948.25 1024.93 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2184.74 1419.81 764.93 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2164.71 1407.14 757.57 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2347.31 1509.03 838.28 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2369.96 1524.60 845.36 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4106.84 2657.32 1449.53 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4016.93 2599.68 1417.24 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   3400.35 2199.59 1200.76 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3010.14 1977.45 1032.69 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2227.65 1450.30 777.35 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2207.81 1437.74 770.07 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2391.41 1540.41 851.00 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2400.81 1547.54 853.27 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4117.02 2668.14 1448.88 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4028.65 2611.48 1417.17 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   3395.33 2200.57 1194.76 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3034.38 1994.12 1040.26 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2247.30 1465.24 782.06 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2227.55 1452.73 774.82 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2410.14 1554.80 855.34 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2417.30 1560.51 856.78 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4158.84 2698.28 1460.56 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4072.71 2643.02 1429.70 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SE Coil:Cooling:WaterToAirHeatPump:EquationFit   3439.66 2232.22 1207.44 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3077.10 2024.77 1052.33 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2295.42 1497.75 797.67 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2275.75 1485.29 790.46 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2456.49 1586.38 870.11 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2463.12 1591.76 871.36 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4107.38 2668.62 1438.77 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4020.59 2612.95 1407.64 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   3398.79 2207.99 1190.80 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3025.97 1995.13 1030.84 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2250.64 1471.15 779.48 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2231.12 1458.78 772.33 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2412.06 1559.73 852.34 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2418.41 1564.94 853.47 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4090.25 2660.39 1429.85 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4004.31 2605.28 1399.03 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   3386.97 2203.00 1183.97 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3009.82 1987.41 1022.41 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2239.43 1465.59 773.83 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2220.02 1453.29 766.73 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2399.99 1553.51 846.47 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2406.11 1558.60 847.52 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4093.59 2664.92 1428.67 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4008.49 2610.33 1398.16 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   3393.58 2209.50 1184.08 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3012.60 1991.48 1021.11 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2248.14 1472.49 775.65 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2228.86 1460.27 768.60 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2406.58 1559.07 847.51 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2412.52 1564.04 848.48 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4235.91 2757.64 1478.27 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4151.08 2703.15 1447.93 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   3496.63 2277.35 1219.28 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3063.96 2026.37 1037.59 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2375.11 1554.21 820.90 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2355.64 1541.86 813.78 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2496.23 1617.52 878.71 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2507.13 1624.55 882.58 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5241.32 3395.82 1845.50 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5079.47 3295.62 1783.85 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4495.28 2915.56 1579.71 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3904.45 2557.56 1346.89 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3104.20 2006.55 1097.65 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3100.56 2004.20 1096.36 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3617.14 2333.28 1283.86 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3623.11 2338.17 1284.94 0.65 0.00    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
None            


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
HEAT PUMP HEATING MODE AIRLOOP G SW Coil:Heating:WaterToAirHeatPump:EquationFit   3205.74 0.00
HEAT PUMP HEATING MODE AIRLOOP G NW Coil:Heating:WaterToAirHeatPump:EquationFit   3148.90 0.00
HEAT PUMP HEATING MODE AIRLOOP OFFICE Coil:Heating:WaterToAirHeatPump:EquationFit   4016.33 0.00
HEAT PUMP HEATING MODE AIRLOOP G NE Coil:Heating:WaterToAirHeatPump:EquationFit   2247.30 0.00
HEAT PUMP HEATING MODE AIRLOOP G N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1649.01 0.00
HEAT PUMP HEATING MODE AIRLOOP G N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1624.43 0.00
HEAT PUMP HEATING MODE AIRLOOP G S1 Coil:Heating:WaterToAirHeatPump:EquationFit   1773.44 0.00
HEAT PUMP HEATING MODE AIRLOOP G S2 Coil:Heating:WaterToAirHeatPump:EquationFit   1845.11 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4097.56 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3998.19 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SE Coil:Heating:WaterToAirHeatPump:EquationFit   3602.22 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2973.18 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2184.74 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2164.71 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2347.31 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2369.96 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4106.84 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4016.93 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SE Coil:Heating:WaterToAirHeatPump:EquationFit   3400.35 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3010.14 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2227.65 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2207.81 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2391.41 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2400.81 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4117.02 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4028.65 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SE Coil:Heating:WaterToAirHeatPump:EquationFit   3395.33 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3034.38 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2247.30 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2227.55 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2410.14 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2417.30 0.00
HEAT PUMP HEATING MODE AIRLOOP M SW Coil:Heating:WaterToAirHeatPump:EquationFit   4158.84 0.00
HEAT PUMP HEATING MODE AIRLOOP M NW Coil:Heating:WaterToAirHeatPump:EquationFit   4072.71 0.00
HEAT PUMP HEATING MODE AIRLOOP M SE Coil:Heating:WaterToAirHeatPump:EquationFit   3439.66 0.00
HEAT PUMP HEATING MODE AIRLOOP M NE Coil:Heating:WaterToAirHeatPump:EquationFit   3077.10 0.00
HEAT PUMP HEATING MODE AIRLOOP M N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2295.42 0.00
HEAT PUMP HEATING MODE AIRLOOP M N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2275.75 0.00
HEAT PUMP HEATING MODE AIRLOOP M S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2456.49 0.00
HEAT PUMP HEATING MODE AIRLOOP M S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2463.12 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4107.38 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4020.59 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SE Coil:Heating:WaterToAirHeatPump:EquationFit   3398.79 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3025.97 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2250.64 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2231.12 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2412.06 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2418.41 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4090.25 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4004.31 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SE Coil:Heating:WaterToAirHeatPump:EquationFit   3386.97 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3009.82 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2239.43 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2220.02 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2399.99 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2406.11 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4093.59 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4008.49 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SE Coil:Heating:WaterToAirHeatPump:EquationFit   3393.58 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3012.60 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2248.14 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2228.86 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2406.58 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2412.52 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4235.91 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4151.08 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SE Coil:Heating:WaterToAirHeatPump:EquationFit   3496.63 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3063.96 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2375.11 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2355.64 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2496.23 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2507.13 0.00
HEAT PUMP HEATING MODE AIRLOOP T SW Coil:Heating:WaterToAirHeatPump:EquationFit   5241.32 0.00
HEAT PUMP HEATING MODE AIRLOOP T NW Coil:Heating:WaterToAirHeatPump:EquationFit   5079.47 0.00
HEAT PUMP HEATING MODE AIRLOOP T SE Coil:Heating:WaterToAirHeatPump:EquationFit   4495.28 0.00
HEAT PUMP HEATING MODE AIRLOOP T NE Coil:Heating:WaterToAirHeatPump:EquationFit   3904.45 0.00
HEAT PUMP HEATING MODE AIRLOOP T N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3104.20 0.00
HEAT PUMP HEATING MODE AIRLOOP T N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3100.56 0.00
HEAT PUMP HEATING MODE AIRLOOP T S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3617.14 0.00
HEAT PUMP HEATING MODE AIRLOOP T S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3623.11 0.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW Coil:Heating:Electric   2438.18 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW Coil:Heating:Electric   2437.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE Coil:Heating:Electric   3204.67 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE Coil:Heating:Electric   2437.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 Coil:Heating:Electric   1803.85 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 Coil:Heating:Electric   1803.85 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 Coil:Heating:Electric   1801.10 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 Coil:Heating:Electric   1809.61 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW Coil:Heating:Electric   2417.40 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW Coil:Heating:Electric   2415.07 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE Coil:Heating:Electric   2442.87 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE Coil:Heating:Electric   2415.07 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 Coil:Heating:Electric   1636.45 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 Coil:Heating:Electric   1636.45 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 Coil:Heating:Electric   1641.48 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 Coil:Heating:Electric   1643.18 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW Coil:Heating:Electric   2408.10 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW Coil:Heating:Electric   2408.73 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE Coil:Heating:Electric   2410.95 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE Coil:Heating:Electric   2408.73 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 Coil:Heating:Electric   1603.57 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 Coil:Heating:Electric   1603.57 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 Coil:Heating:Electric   1603.68 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 Coil:Heating:Electric   1603.96 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW Coil:Heating:Electric   2437.51 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW Coil:Heating:Electric   2440.24 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE Coil:Heating:Electric   2437.81 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE Coil:Heating:Electric   2440.24 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 Coil:Heating:Electric   1613.44 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 Coil:Heating:Electric   1613.44 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 Coil:Heating:Electric   1611.18 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 Coil:Heating:Electric   1611.22 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW Coil:Heating:Electric   2444.07 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW Coil:Heating:Electric   2447.13 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE Coil:Heating:Electric   2444.10 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE Coil:Heating:Electric   2447.13 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 Coil:Heating:Electric   1605.70 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 Coil:Heating:Electric   1605.70 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 Coil:Heating:Electric   1603.05 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 Coil:Heating:Electric   1603.05 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW Coil:Heating:Electric   2518.98 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW Coil:Heating:Electric   2524.13 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE Coil:Heating:Electric   2518.98 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE Coil:Heating:Electric   2524.13 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 Coil:Heating:Electric   1664.53 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 Coil:Heating:Electric   1664.53 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 Coil:Heating:Electric   1659.73 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 Coil:Heating:Electric   1659.73 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW Coil:Heating:Electric   2566.03 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW Coil:Heating:Electric   2571.88 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE Coil:Heating:Electric   2566.03 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE Coil:Heating:Electric   2571.88 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 Coil:Heating:Electric   1699.07 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 Coil:Heating:Electric   1699.07 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 Coil:Heating:Electric   1693.52 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 Coil:Heating:Electric   1693.52 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW Coil:Heating:Electric   2617.09 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW Coil:Heating:Electric   2623.31 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE Coil:Heating:Electric   2617.09 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE Coil:Heating:Electric   2623.31 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 Coil:Heating:Electric   1739.23 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 Coil:Heating:Electric   1739.23 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 Coil:Heating:Electric   1733.27 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 Coil:Heating:Electric   1733.27 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW Coil:Heating:Electric   2787.45 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW Coil:Heating:Electric   2791.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE Coil:Heating:Electric   2787.45 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE Coil:Heating:Electric   2791.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 Coil:Heating:Electric   1889.52 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 Coil:Heating:Electric   1889.52 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 Coil:Heating:Electric   1885.05 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 Coil:Heating:Electric   1885.05 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW Coil:Heating:Electric   3391.52 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW Coil:Heating:Electric   3402.45 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE Coil:Heating:Electric   3391.52 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE Coil:Heating:Electric   3402.45 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 Coil:Heating:Electric   2545.49 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 Coil:Heating:Electric   2545.49 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 Coil:Heating:Electric   2531.48 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 Coil:Heating:Electric   2531.48 1.00


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
AIRLOOP G SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 290.01 1120.11 1.00 General
AIRLOOP G NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 285.64 1120.11 1.00 General
AIRLOOP OFFICE SUPPLY FAN Fan:OnOff 0.56 622.50 0.33 367.07 1120.11 1.00 General
AIRLOOP G NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 208.20 1120.11 1.00 General
AIRLOOP G N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.13 148.94 1120.11 1.00 General
AIRLOOP G N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.13 146.71 1120.11 1.00 General
AIRLOOP G S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 152.70 1120.11 1.00 General
AIRLOOP G S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 159.27 1120.11 1.00 General
AIRLOOP F2 SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.33 373.65 1120.11 1.00 General
AIRLOOP F2 NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.33 365.28 1120.11 1.00 General
AIRLOOP F2 SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.29 324.30 1120.11 1.00 General
AIRLOOP F2 NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.25 276.83 1120.11 1.00 General
AIRLOOP F2 N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 198.70 1120.11 1.00 General
AIRLOOP F2 N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 196.88 1120.11 1.00 General
AIRLOOP F2 S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 205.97 1120.11 1.00 General
AIRLOOP F2 S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 208.45 1120.11 1.00 General
AIRLOOP F3 SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.34 375.65 1120.11 1.00 General
AIRLOOP F3 NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.33 368.14 1120.11 1.00 General
AIRLOOP F3 SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 306.86 1120.11 1.00 General
AIRLOOP F3 NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.25 281.34 1120.11 1.00 General
AIRLOOP F3 N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 203.27 1120.11 1.00 General
AIRLOOP F3 N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 201.46 1120.11 1.00 General
AIRLOOP F3 S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 210.65 1120.11 1.00 General
AIRLOOP F3 S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 211.92 1120.11 1.00 General
AIRLOOP F4 SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.34 377.44 1120.11 1.00 General
AIRLOOP F4 NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.33 370.07 1120.11 1.00 General
AIRLOOP F4 SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 307.22 1120.11 1.00 General
AIRLOOP F4 NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.25 283.19 1120.11 1.00 General
AIRLOOP F4 N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 205.55 1120.11 1.00 General
AIRLOOP F4 N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 203.75 1120.11 1.00 General
AIRLOOP F4 S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 212.85 1120.11 1.00 General
AIRLOOP F4 S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 213.91 1120.11 1.00 General
AIRLOOP M SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.34 381.97 1120.11 1.00 General
AIRLOOP M NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.33 374.81 1120.11 1.00 General
AIRLOOP M SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.28 311.97 1120.11 1.00 General
AIRLOOP M NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 287.80 1120.11 1.00 General
AIRLOOP M N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 210.34 1120.11 1.00 General
AIRLOOP M N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 208.54 1120.11 1.00 General
AIRLOOP M S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 217.50 1120.11 1.00 General
AIRLOOP M S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.20 218.52 1120.11 1.00 General
AIRLOOP F6 SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.34 377.85 1120.11 1.00 General
AIRLOOP F6 NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.33 370.62 1120.11 1.00 General
AIRLOOP F6 SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.28 308.37 1120.11 1.00 General
AIRLOOP F6 NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.25 283.66 1120.11 1.00 General
AIRLOOP F6 N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 206.60 1120.11 1.00 General
AIRLOOP F6 N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 204.82 1120.11 1.00 General
AIRLOOP F6 S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 213.75 1120.11 1.00 General
AIRLOOP F6 S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 214.74 1120.11 1.00 General
AIRLOOP F7 SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.34 376.80 1120.11 1.00 General
AIRLOOP F7 NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.33 369.66 1120.11 1.00 General
AIRLOOP F7 SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 307.78 1120.11 1.00 General
AIRLOOP F7 NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.25 282.68 1120.11 1.00 General
AIRLOOP F7 N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 205.88 1120.11 1.00 General
AIRLOOP F7 N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 204.11 1120.11 1.00 General
AIRLOOP F7 S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 212.93 1120.11 1.00 General
AIRLOOP F7 S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 213.91 1120.11 1.00 General
AIRLOOP F8 SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.34 377.58 1120.11 1.00 General
AIRLOOP F8 NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.33 370.51 1120.11 1.00 General
AIRLOOP F8 SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.28 308.84 1120.11 1.00 General
AIRLOOP F8 NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.25 283.38 1120.11 1.00 General
AIRLOOP F8 N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 206.94 1120.11 1.00 General
AIRLOOP F8 N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 205.18 1120.11 1.00 General
AIRLOOP F8 S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 213.80 1120.11 1.00 General
AIRLOOP F8 S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 214.76 1120.11 1.00 General
AIRLOOP F9 SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.35 391.09 1120.11 1.00 General
AIRLOOP F9 NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.34 384.03 1120.11 1.00 General
AIRLOOP F9 SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.28 318.74 1120.11 1.00 General
AIRLOOP F9 NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 288.54 1120.11 1.00 General
AIRLOOP F9 N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.20 218.78 1120.11 1.00 General
AIRLOOP F9 N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 217.00 1120.11 1.00 General
AIRLOOP F9 S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.20 222.28 1120.11 1.00 General
AIRLOOP F9 S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.20 223.29 1120.11 1.00 General
AIRLOOP T SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.43 481.77 1120.11 1.00 General
AIRLOOP T NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.42 468.45 1120.11 1.00 General
AIRLOOP T SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.37 410.99 1120.11 1.00 General
AIRLOOP T NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.32 363.83 1120.11 1.00 General
AIRLOOP T N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.25 278.40 1120.11 1.00 General
AIRLOOP T N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.25 278.06 1120.11 1.00 General
AIRLOOP T S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.29 325.52 1120.11 1.00 General
AIRLOOP T S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.29 326.49 1120.11 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
SHWSYS1 PUMP Pump:ConstantSpeed Intermittent 29891.00 0.0003 36.93 127739.32 0.30
PLANT CIRC PUMP Pump:ConstantSpeed Intermittent 179045.11 0.0053 1356.10 255050.01 0.90


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
SHWSYS1 WATER HEATER WaterHeater:Mixed 2.27 175842.64 0.80 0.00 0.00



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 2266.20 2719.44 0.216 0.259 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 32.87 0.00565
G NW APARTMENT 2232.07 2678.49 0.213 0.255 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 32.20 0.00565
OFFICE 2868.46 3442.15 0.273 0.328 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 11:00:00 32.00 0.00565
G NE APARTMENT 1626.96 1952.35 0.155 0.186 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 30.48 0.00565
G N1 APARTMENT 1163.88 1396.65 0.111 0.133 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 30.85 0.00565
G N2 APARTMENT 1146.45 1375.74 0.109 0.131 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 30.85 0.00565
G S1 APARTMENT 1193.20 1431.83 0.114 0.136 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 34.93 0.00565
G S2 APARTMENT 1244.54 1493.45 0.118 0.142 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 34.93 0.00565
F2 SW APARTMENT 2919.83 3503.80 0.278 0.334 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 32.87 0.00565
F2 NW APARTMENT 2854.39 3425.27 0.272 0.326 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 32.20 0.00565
F2 SE APARTMENT 2534.22 3041.07 0.241 0.290 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 34.76 0.00565
F2 NE APARTMENT 2163.28 2595.93 0.206 0.247 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 30.48 0.00565
F2 N1 APARTMENT 1552.71 1863.25 0.148 0.177 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 30.85 0.00565
F2 N2 APARTMENT 1538.46 1846.15 0.146 0.176 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 30.85 0.00565
F2 S1 APARTMENT 1609.47 1931.37 0.153 0.184 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 35.10 0.00565
F2 S2 APARTMENT 1628.88 1954.66 0.155 0.186 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 34.93 0.00565
F3 SW APARTMENT 2935.44 3522.53 0.279 0.335 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 32.87 0.00565
F3 NW APARTMENT 2876.74 3452.09 0.274 0.329 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 32.20 0.00565
F3 SE APARTMENT 2397.97 2877.57 0.228 0.274 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 34.76 0.00565
F3 NE APARTMENT 2198.53 2638.24 0.209 0.251 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 30.48 0.00565
F3 N1 APARTMENT 1588.37 1906.05 0.151 0.181 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 30.85 0.00565
F3 N2 APARTMENT 1574.24 1889.09 0.150 0.180 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 30.85 0.00565
F3 S1 APARTMENT 1646.07 1975.28 0.157 0.188 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 35.10 0.00565
F3 S2 APARTMENT 1656.00 1987.21 0.158 0.189 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 34.93 0.00565
F4 SW APARTMENT 2949.45 3539.34 0.281 0.337 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 32.87 0.00565
F4 NW APARTMENT 2891.84 3470.21 0.275 0.330 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 32.20 0.00565
F4 SE APARTMENT 2400.78 2880.94 0.229 0.274 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 34.76 0.00565
F4 NE APARTMENT 2212.97 2655.56 0.211 0.253 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 30.98 0.00565
F4 N1 APARTMENT 1606.21 1927.45 0.153 0.184 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 30.85 0.00565
F4 N2 APARTMENT 1592.13 1910.56 0.152 0.182 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 30.85 0.00565
F4 S1 APARTMENT 1663.25 1995.90 0.158 0.190 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 35.10 0.00565
F4 S2 APARTMENT 1671.60 2005.92 0.159 0.191 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 34.93 0.00565
M SW APARTMENT 2984.92 3581.91 0.284 0.341 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 32.87 0.00565
M NW APARTMENT 2928.88 3514.66 0.279 0.335 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 32.20 0.00565
M SE APARTMENT 2437.87 2925.44 0.232 0.279 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 34.76 0.00565
M NE APARTMENT 2248.97 2698.77 0.214 0.257 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 30.98 0.00565
M N1 APARTMENT 1643.64 1972.36 0.156 0.188 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 30.85 0.00565
M N2 APARTMENT 1629.61 1955.53 0.155 0.186 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 30.85 0.00565
M S1 APARTMENT 1699.59 2039.51 0.162 0.194 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 35.10 0.00565
M S2 APARTMENT 1707.57 2049.08 0.163 0.195 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 34.93 0.00565
F6 SW APARTMENT 2952.70 3543.24 0.281 0.337 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 32.87 0.00565
F6 NW APARTMENT 2896.21 3475.45 0.276 0.331 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 32.20 0.00565
F6 SE APARTMENT 2409.73 2891.68 0.229 0.275 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 34.93 0.00565
F6 NE APARTMENT 2216.68 2660.01 0.211 0.253 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 30.98 0.00565
F6 N1 APARTMENT 1614.42 1937.30 0.154 0.184 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 30.85 0.00565
F6 N2 APARTMENT 1600.49 1920.59 0.152 0.183 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 30.85 0.00565
F6 S1 APARTMENT 1670.30 2004.36 0.159 0.191 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 35.10 0.00565
F6 S2 APARTMENT 1678.09 2013.71 0.160 0.192 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 34.93 0.00565
F7 SW APARTMENT 2944.52 3533.42 0.280 0.336 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 32.87 0.00565
F7 NW APARTMENT 2888.65 3466.38 0.275 0.330 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 32.20 0.00565
F7 SE APARTMENT 2405.15 2886.18 0.229 0.275 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 34.93 0.00565
F7 NE APARTMENT 2208.99 2650.79 0.210 0.252 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 30.98 0.00565
F7 N1 APARTMENT 1608.79 1930.54 0.153 0.184 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 30.85 0.00565
F7 N2 APARTMENT 1594.94 1913.92 0.152 0.182 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 30.85 0.00565
F7 S1 APARTMENT 1663.92 1996.71 0.158 0.190 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 35.10 0.00565
F7 S2 APARTMENT 1671.57 2005.88 0.159 0.191 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 34.93 0.00565
F8 SW APARTMENT 2950.61 3540.73 0.281 0.337 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 32.87 0.00565
F8 NW APARTMENT 2895.33 3474.40 0.276 0.331 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 32.20 0.00565
F8 SE APARTMENT 2413.41 2896.09 0.230 0.276 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 34.93 0.00565
F8 NE APARTMENT 2214.53 2657.43 0.211 0.253 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 30.98 0.00565
F8 N1 APARTMENT 1617.11 1940.54 0.154 0.185 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 30.85 0.00565
F8 N2 APARTMENT 1603.35 1924.02 0.153 0.183 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 30.85 0.00565
F8 S1 APARTMENT 1670.72 2004.86 0.159 0.191 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 35.10 0.00565
F8 S2 APARTMENT 1678.24 2013.89 0.160 0.192 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 34.93 0.00565
F9 SW APARTMENT 3056.15 3667.38 0.291 0.349 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 32.87 0.00565
F9 NW APARTMENT 3000.97 3601.17 0.286 0.343 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 32.20 0.00565
F9 SE APARTMENT 2490.81 2988.97 0.237 0.285 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 34.93 0.00565
F9 NE APARTMENT 2254.79 2705.75 0.215 0.258 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 30.98 0.00565
F9 N1 APARTMENT 1709.64 2051.57 0.163 0.195 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 30.85 0.00565
F9 N2 APARTMENT 1695.73 2034.87 0.161 0.194 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 30.85 0.00565
F9 S1 APARTMENT 1736.97 2084.36 0.165 0.198 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 35.10 0.00565
F9 S2 APARTMENT 1744.91 2093.90 0.166 0.199 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 35.10 0.00565
T SW APARTMENT 3764.81 4517.77 0.358 0.430 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 34.02 0.00565
T NW APARTMENT 3660.74 4392.88 0.349 0.418 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:00:00 33.21 0.00565
T SE APARTMENT 3211.70 3854.04 0.306 0.367 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 34.93 0.00565
T NE APARTMENT 2843.22 3411.87 0.271 0.325 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 11:00:00 32.00 0.00565
T N1 APARTMENT 2175.55 2610.66 0.207 0.249 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:45:00 35.10 0.00565
T N2 APARTMENT 2172.89 2607.47 0.207 0.248 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:45:00 35.10 0.00565
T S1 APARTMENT 2543.78 3052.53 0.242 0.291 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 35.10 0.00565
T S2 APARTMENT 2551.30 3061.56 0.243 0.291 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 34.93 0.00565


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1415.34 1698.40 0.077 0.092 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.90 0.00234
G NW APARTMENT 1414.58 1697.50 0.077 0.092 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.90 0.00234
OFFICE 1760.83 2113.00 0.095 0.114 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 18:45:00 -7.90 0.00234
G NE APARTMENT 1414.58 1697.50 0.077 0.092 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.90 0.00234
G N1 APARTMENT 878.91 1054.69 0.048 0.057 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.90 0.00234
G N2 APARTMENT 878.91 1054.69 0.048 0.057 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.90 0.00234
G S1 APARTMENT 876.59 1051.90 0.047 0.057 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.90 0.00234
G S2 APARTMENT 883.79 1060.54 0.048 0.057 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.90 0.00234
F2 SW APARTMENT 1397.78 1677.34 0.076 0.091 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F2 NW APARTMENT 1395.81 1674.97 0.076 0.091 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F2 SE APARTMENT 1419.32 1703.19 0.077 0.092 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F2 NE APARTMENT 1395.81 1674.97 0.076 0.091 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F2 N1 APARTMENT 737.36 884.84 0.040 0.048 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F2 N2 APARTMENT 737.36 884.84 0.040 0.048 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F2 S1 APARTMENT 741.62 889.94 0.040 0.048 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F2 S2 APARTMENT 743.06 891.67 0.040 0.048 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F3 SW APARTMENT 1389.93 1667.91 0.075 0.090 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F3 NW APARTMENT 1390.46 1668.55 0.075 0.090 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F3 SE APARTMENT 1392.33 1670.80 0.075 0.090 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F3 NE APARTMENT 1390.46 1668.55 0.075 0.090 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F3 N1 APARTMENT 709.56 851.47 0.038 0.046 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F3 N2 APARTMENT 709.56 851.47 0.038 0.046 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F3 S1 APARTMENT 709.66 851.59 0.038 0.046 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F3 S2 APARTMENT 709.89 851.86 0.038 0.046 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F4 SW APARTMENT 1414.80 1697.75 0.077 0.092 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F4 NW APARTMENT 1417.11 1700.53 0.077 0.092 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F4 SE APARTMENT 1415.05 1698.06 0.077 0.092 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F4 NE APARTMENT 1417.11 1700.53 0.077 0.092 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F4 N1 APARTMENT 717.91 861.49 0.039 0.047 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F4 N2 APARTMENT 717.91 861.49 0.039 0.047 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F4 S1 APARTMENT 716.00 859.20 0.039 0.046 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F4 S2 APARTMENT 716.03 859.23 0.039 0.046 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
M SW APARTMENT 1420.35 1704.42 0.077 0.092 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
M NW APARTMENT 1422.94 1707.52 0.077 0.092 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
M SE APARTMENT 1420.37 1704.45 0.077 0.092 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
M NE APARTMENT 1422.94 1707.52 0.077 0.092 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
M N1 APARTMENT 711.36 853.64 0.038 0.046 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
M N2 APARTMENT 711.36 853.64 0.038 0.046 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
M S1 APARTMENT 709.12 850.95 0.038 0.046 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
M S2 APARTMENT 709.13 850.95 0.038 0.046 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F6 SW APARTMENT 1483.70 1780.44 0.080 0.096 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F6 NW APARTMENT 1488.05 1785.66 0.081 0.097 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F6 SE APARTMENT 1483.70 1780.44 0.080 0.096 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F6 NE APARTMENT 1488.05 1785.66 0.081 0.097 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F6 N1 APARTMENT 761.12 913.34 0.041 0.049 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F6 N2 APARTMENT 761.12 913.34 0.041 0.049 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F6 S1 APARTMENT 757.06 908.47 0.041 0.049 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F6 S2 APARTMENT 757.06 908.47 0.041 0.049 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F7 SW APARTMENT 1523.49 1828.19 0.082 0.099 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F7 NW APARTMENT 1528.44 1834.12 0.083 0.099 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F7 SE APARTMENT 1523.49 1828.19 0.082 0.099 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F7 NE APARTMENT 1528.44 1834.12 0.083 0.099 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F7 N1 APARTMENT 790.33 948.40 0.043 0.051 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F7 N2 APARTMENT 790.33 948.40 0.043 0.051 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F7 S1 APARTMENT 785.64 942.76 0.043 0.051 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F7 S2 APARTMENT 785.64 942.76 0.043 0.051 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F8 SW APARTMENT 1566.67 1880.01 0.085 0.102 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F8 NW APARTMENT 1571.93 1886.31 0.085 0.102 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F8 SE APARTMENT 1566.67 1880.01 0.085 0.102 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F8 NE APARTMENT 1571.93 1886.31 0.085 0.102 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F8 N1 APARTMENT 824.29 989.15 0.045 0.054 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F8 N2 APARTMENT 824.29 989.15 0.045 0.054 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F8 S1 APARTMENT 819.25 983.10 0.044 0.053 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F8 S2 APARTMENT 819.25 983.10 0.044 0.053 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F9 SW APARTMENT 1710.73 2052.88 0.093 0.111 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F9 NW APARTMENT 1714.29 2057.14 0.093 0.111 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F9 SE APARTMENT 1710.73 2052.88 0.093 0.111 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F9 NE APARTMENT 1714.29 2057.14 0.093 0.111 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F9 N1 APARTMENT 951.39 1141.66 0.051 0.062 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F9 N2 APARTMENT 951.39 1141.66 0.051 0.062 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F9 S1 APARTMENT 947.61 1137.13 0.051 0.062 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
F9 S2 APARTMENT 947.61 1137.13 0.051 0.062 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
T SW APARTMENT 2221.57 2665.88 0.120 0.144 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
T NW APARTMENT 2230.81 2676.98 0.121 0.145 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
T SE APARTMENT 2221.57 2665.88 0.120 0.144 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
T NE APARTMENT 2230.81 2676.98 0.121 0.145 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
T N1 APARTMENT 1506.11 1807.33 0.081 0.098 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
T N2 APARTMENT 1506.11 1807.33 0.081 0.098 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
T S1 APARTMENT 1494.26 1793.12 0.081 0.097 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234
T S2 APARTMENT 1494.26 1793.12 0.081 0.097 ALBUQUERQUE.INTL.SUNPORT_NM_USA ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.90 0.00234


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
AIRLOOP G SW 0.26 0.26 0.09 0.09
AIRLOOP G NW 0.26 0.26 0.09 0.09
AIRLOOP OFFICE 0.33 0.33 0.11 0.11
AIRLOOP G NE 0.19 0.19 0.09 0.09
AIRLOOP G N1 0.13 0.13 0.06 0.06
AIRLOOP G N2 0.13 0.13 0.06 0.06
AIRLOOP G S1 0.14 0.14 0.06 0.06
AIRLOOP G S2 0.14 0.14 0.06 0.06
AIRLOOP F2 SW 0.33 0.33 0.09 0.09
AIRLOOP F2 NW 0.33 0.33 0.09 0.09
AIRLOOP F2 SE 0.29 0.29 0.09 0.09
AIRLOOP F2 NE 0.25 0.25 0.09 0.09
AIRLOOP F2 N1 0.18 0.18 0.05 0.05
AIRLOOP F2 N2 0.18 0.18 0.05 0.05
AIRLOOP F2 S1 0.18 0.18 0.05 0.05
AIRLOOP F2 S2 0.19 0.19 0.05 0.05
AIRLOOP F3 SW 0.34 0.34 0.09 0.09
AIRLOOP F3 NW 0.33 0.33 0.09 0.09
AIRLOOP F3 SE 0.27 0.27 0.09 0.09
AIRLOOP F3 NE 0.25 0.25 0.09 0.09
AIRLOOP F3 N1 0.18 0.18 0.05 0.05
AIRLOOP F3 N2 0.18 0.18 0.05 0.05
AIRLOOP F3 S1 0.19 0.19 0.05 0.05
AIRLOOP F3 S2 0.19 0.19 0.05 0.05
AIRLOOP F4 SW 0.34 0.34 0.09 0.09
AIRLOOP F4 NW 0.33 0.33 0.09 0.09
AIRLOOP F4 SE 0.27 0.27 0.09 0.09
AIRLOOP F4 NE 0.25 0.25 0.09 0.09
AIRLOOP F4 N1 0.18 0.18 0.05 0.05
AIRLOOP F4 N2 0.18 0.18 0.05 0.05
AIRLOOP F4 S1 0.19 0.19 0.05 0.05
AIRLOOP F4 S2 0.19 0.19 0.05 0.05
AIRLOOP M SW 0.34 0.34 0.09 0.09
AIRLOOP M NW 0.33 0.33 0.09 0.09
AIRLOOP M SE 0.28 0.28 0.09 0.09
AIRLOOP M NE 0.26 0.26 0.09 0.09
AIRLOOP M N1 0.19 0.19 0.05 0.05
AIRLOOP M N2 0.19 0.19 0.05 0.05
AIRLOOP M S1 0.19 0.19 0.05 0.05
AIRLOOP M S2 0.20 0.20 0.05 0.05
AIRLOOP F6 SW 0.34 0.34 0.10 0.10
AIRLOOP F6 NW 0.33 0.33 0.10 0.10
AIRLOOP F6 SE 0.28 0.28 0.10 0.10
AIRLOOP F6 NE 0.25 0.25 0.10 0.10
AIRLOOP F6 N1 0.18 0.18 0.05 0.05
AIRLOOP F6 N2 0.18 0.18 0.05 0.05
AIRLOOP F6 S1 0.19 0.19 0.05 0.05
AIRLOOP F6 S2 0.19 0.19 0.05 0.05
AIRLOOP F7 SW 0.34 0.34 0.10 0.10
AIRLOOP F7 NW 0.33 0.33 0.10 0.10
AIRLOOP F7 SE 0.27 0.27 0.10 0.10
AIRLOOP F7 NE 0.25 0.25 0.10 0.10
AIRLOOP F7 N1 0.18 0.18 0.05 0.05
AIRLOOP F7 N2 0.18 0.18 0.05 0.05
AIRLOOP F7 S1 0.19 0.19 0.05 0.05
AIRLOOP F7 S2 0.19 0.19 0.05 0.05
AIRLOOP F8 SW 0.34 0.34 0.10 0.10
AIRLOOP F8 NW 0.33 0.33 0.10 0.10
AIRLOOP F8 SE 0.28 0.28 0.10 0.10
AIRLOOP F8 NE 0.25 0.25 0.10 0.10
AIRLOOP F8 N1 0.18 0.18 0.05 0.05
AIRLOOP F8 N2 0.18 0.18 0.05 0.05
AIRLOOP F8 S1 0.19 0.19 0.05 0.05
AIRLOOP F8 S2 0.19 0.19 0.05 0.05
AIRLOOP F9 SW 0.35 0.35 0.11 0.11
AIRLOOP F9 NW 0.34 0.34 0.11 0.11
AIRLOOP F9 SE 0.28 0.28 0.11 0.11
AIRLOOP F9 NE 0.26 0.26 0.11 0.11
AIRLOOP F9 N1 0.20 0.20 0.06 0.06
AIRLOOP F9 N2 0.19 0.19 0.06 0.06
AIRLOOP F9 S1 0.20 0.20 0.06 0.06
AIRLOOP F9 S2 0.20 0.20 0.06 0.06
AIRLOOP T SW 0.43 0.43 0.14 0.14
AIRLOOP T NW 0.42 0.42 0.14 0.14
AIRLOOP T SE 0.37 0.37 0.14 0.14
AIRLOOP T NE 0.32 0.32 0.14 0.14
AIRLOOP T N1 0.25 0.25 0.10 0.10
AIRLOOP T N2 0.25 0.25 0.10 0.10
AIRLOOP T S1 0.29 0.29 0.10 0.10
AIRLOOP T S2 0.29 0.29 0.10 0.10



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 2925.75 4649.25 294.25
G NW APARTMENT 2651.50 5764.00 406.75
OFFICE 939.25 518.75 1.25
G NE APARTMENT 2752.75 5701.50 445.00
G N1 APARTMENT 2413.75 6123.75 445.25
G N2 APARTMENT 2417.75 6119.50 447.75
G S1 APARTMENT 2767.25 4979.25 364.25
G S2 APARTMENT 2794.50 4903.75 355.25
F2 SW APARTMENT 3772.50 2740.75 150.00
F2 NW APARTMENT 3067.00 4746.50 182.00
F2 SE APARTMENT 3942.25 2563.50 114.75
F2 NE APARTMENT 3188.75 4686.25 190.75
F2 N1 APARTMENT 2865.00 5108.50 239.75
F2 N2 APARTMENT 2873.25 5102.50 239.00
F2 S1 APARTMENT 3724.75 2558.50 191.25
F2 S2 APARTMENT 3740.75 2531.00 188.50
F3 SW APARTMENT 3936.75 2405.75 148.25
F3 NW APARTMENT 3149.00 4482.25 174.00
F3 SE APARTMENT 4025.00 2396.25 124.00
F3 NE APARTMENT 3244.50 4460.50 176.00
F3 N1 APARTMENT 2983.50 4748.00 215.75
F3 N2 APARTMENT 2989.50 4745.50 216.00
F3 S1 APARTMENT 3999.50 2047.50 180.00
F3 S2 APARTMENT 4002.75 2042.75 178.75
F4 SW APARTMENT 3968.50 2374.75 150.75
F4 NW APARTMENT 3161.50 4407.00 175.00
F4 SE APARTMENT 4035.75 2393.00 128.00
F4 NE APARTMENT 3259.75 4406.25 175.50
F4 N1 APARTMENT 3007.50 4626.75 212.25
F4 N2 APARTMENT 3017.25 4623.25 212.00
F4 S1 APARTMENT 4057.00 1948.00 177.75
F4 S2 APARTMENT 4058.25 1947.75 176.50
M SW APARTMENT 3976.00 2368.50 149.00
M NW APARTMENT 3171.75 4374.00 172.50
M SE APARTMENT 4034.50 2388.25 128.50
M NE APARTMENT 3272.00 4385.00 173.50
M N1 APARTMENT 3028.75 4556.50 205.00
M N2 APARTMENT 3038.75 4560.00 204.25
M S1 APARTMENT 4075.50 1904.50 173.75
M S2 APARTMENT 4074.00 1907.00 172.75
F6 SW APARTMENT 3858.50 2543.25 157.50
F6 NW APARTMENT 3120.00 4520.50 186.00
F6 SE APARTMENT 3921.50 2554.75 138.25
F6 NE APARTMENT 3226.00 4506.00 190.25
F6 N1 APARTMENT 2959.50 4713.75 217.25
F6 N2 APARTMENT 2964.75 4717.75 217.25
F6 S1 APARTMENT 3946.00 2111.25 184.00
F6 S2 APARTMENT 3949.25 2111.50 183.25
F7 SW APARTMENT 3783.25 2680.00 161.00
F7 NW APARTMENT 3089.00 4607.50 193.25
F7 SE APARTMENT 3851.00 2686.25 144.25
F7 NE APARTMENT 3204.50 4582.25 205.00
F7 N1 APARTMENT 2930.50 4815.00 224.25
F7 N2 APARTMENT 2934.75 4812.00 224.50
F7 S1 APARTMENT 3862.00 2257.50 190.50
F7 S2 APARTMENT 3866.00 2260.25 189.75
F8 SW APARTMENT 3713.25 2807.75 163.50
F8 NW APARTMENT 3065.50 4675.25 199.75
F8 SE APARTMENT 3775.50 2815.50 147.75
F8 NE APARTMENT 3189.00 4662.00 218.75
F8 N1 APARTMENT 2908.50 4881.75 227.25
F8 N2 APARTMENT 2912.25 4882.25 227.50
F8 S1 APARTMENT 3781.75 2406.75 193.50
F8 S2 APARTMENT 3785.50 2407.00 193.50
F9 SW APARTMENT 3613.00 3028.50 160.00
F9 NW APARTMENT 3065.25 4761.00 217.50
F9 SE APARTMENT 3653.50 3018.25 145.75
F9 NE APARTMENT 3188.50 4735.00 241.25
F9 N1 APARTMENT 2892.00 4943.50 218.50
F9 N2 APARTMENT 2901.00 4940.00 218.75
F9 S1 APARTMENT 3621.75 2672.75 188.50
F9 S2 APARTMENT 3626.50 2671.50 187.75
T SW APARTMENT 4008.00 3812.25 386.75
T NW APARTMENT 3445.25 4895.25 717.50
T SE APARTMENT 4129.00 3728.75 396.75
T NE APARTMENT 3558.00 4896.75 741.25
T N1 APARTMENT 3005.75 5150.50 454.25
T N2 APARTMENT 3010.00 5138.50 456.50
T S1 APARTMENT 3807.00 3609.25 262.75
T S2 APARTMENT 3818.50 3607.00 262.75
G CORRIDOR 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00
Facility 5369.50 6249.50 1030.25
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 2.75 50.00 2.75 50.00
G NW APARTMENT 2.50 35.50 2.50 35.50
OFFICE 1.50 24.25 0.00 24.00
G NE APARTMENT 8.75 68.00 8.75 68.00
G N1 APARTMENT 3.25 54.75 3.25 54.75
G N2 APARTMENT 7.00 57.25 7.00 57.25
G S1 APARTMENT 0.00 253.00 0.00 253.00
G S2 APARTMENT 0.00 201.75 0.00 201.75
F2 SW APARTMENT 0.50 52.00 0.50 52.00
F2 NW APARTMENT 0.25 32.50 0.25 32.50
F2 SE APARTMENT 1.00 61.25 1.00 61.25
F2 NE APARTMENT 3.25 78.75 3.25 78.75
F2 N1 APARTMENT 2.50 45.25 2.50 45.25
F2 N2 APARTMENT 2.00 47.50 2.00 47.50
F2 S1 APARTMENT 0.00 289.25 0.00 289.25
F2 S2 APARTMENT 0.00 271.75 0.00 271.75
F3 SW APARTMENT 0.00 70.25 0.00 70.25
F3 NW APARTMENT 0.00 38.75 0.00 38.75
F3 SE APARTMENT 1.00 123.25 1.00 123.25
F3 NE APARTMENT 2.75 92.25 2.75 92.25
F3 N1 APARTMENT 1.75 57.75 1.75 57.75
F3 N2 APARTMENT 1.25 60.00 1.25 60.00
F3 S1 APARTMENT 0.00 349.50 0.00 349.50
F3 S2 APARTMENT 0.00 341.25 0.00 341.25
F4 SW APARTMENT 0.25 76.00 0.25 76.00
F4 NW APARTMENT 0.25 41.25 0.25 41.25
F4 SE APARTMENT 0.50 136.00 0.50 136.00
F4 NE APARTMENT 2.75 93.25 2.75 93.25
F4 N1 APARTMENT 2.00 62.00 2.00 62.00
F4 N2 APARTMENT 2.25 65.00 2.25 65.00
F4 S1 APARTMENT 0.00 367.00 0.00 367.00
F4 S2 APARTMENT 0.00 359.50 0.00 359.50
M SW APARTMENT 0.25 77.50 0.25 77.50
M NW APARTMENT 0.25 43.25 0.25 43.25
M SE APARTMENT 1.50 135.00 1.50 135.00
M NE APARTMENT 2.50 98.25 2.50 98.25
M N1 APARTMENT 1.75 64.25 1.75 64.25
M N2 APARTMENT 1.25 66.50 1.25 66.50
M S1 APARTMENT 0.00 360.25 0.00 360.25
M S2 APARTMENT 0.00 352.75 0.00 352.75
F6 SW APARTMENT 0.50 77.50 0.50 77.50
F6 NW APARTMENT 0.50 44.25 0.50 44.25
F6 SE APARTMENT 1.25 132.50 1.25 132.50
F6 NE APARTMENT 2.50 105.50 2.50 105.50
F6 N1 APARTMENT 1.75 67.25 1.75 67.25
F6 N2 APARTMENT 1.75 70.75 1.75 70.75
F6 S1 APARTMENT 0.00 349.00 0.00 349.00
F6 S2 APARTMENT 0.00 343.25 0.00 343.25
F7 SW APARTMENT 0.00 80.25 0.00 80.25
F7 NW APARTMENT 0.25 45.75 0.25 45.75
F7 SE APARTMENT 0.00 129.00 0.00 129.00
F7 NE APARTMENT 2.50 110.00 2.50 110.00
F7 N1 APARTMENT 1.75 70.00 1.75 70.00
F7 N2 APARTMENT 1.25 74.75 1.25 74.75
F7 S1 APARTMENT 0.00 335.75 0.00 335.75
F7 S2 APARTMENT 0.00 331.25 0.00 331.25
F8 SW APARTMENT 0.25 79.25 0.25 79.25
F8 NW APARTMENT 0.25 46.25 0.25 46.25
F8 SE APARTMENT 0.50 125.50 0.50 125.50
F8 NE APARTMENT 1.50 112.50 1.50 112.50
F8 N1 APARTMENT 2.00 70.75 2.00 70.75
F8 N2 APARTMENT 3.25 75.50 3.25 75.50
F8 S1 APARTMENT 0.00 316.75 0.00 316.75
F8 S2 APARTMENT 0.00 314.75 0.00 314.75
F9 SW APARTMENT 0.00 67.50 0.00 67.50
F9 NW APARTMENT 0.00 45.25 0.00 45.25
F9 SE APARTMENT 0.25 104.75 0.25 104.75
F9 NE APARTMENT 1.50 127.75 1.50 127.75
F9 N1 APARTMENT 4.00 66.00 4.00 66.00
F9 N2 APARTMENT 3.25 69.75 3.25 69.75
F9 S1 APARTMENT 0.00 259.25 0.00 259.25
F9 S2 APARTMENT 0.25 251.50 0.25 251.50
T SW APARTMENT 0.00 63.50 0.00 63.50
T NW APARTMENT 0.00 48.00 0.00 48.00
T SE APARTMENT 0.00 76.75 0.00 76.75
T NE APARTMENT 0.00 77.50 0.00 77.50
T N1 APARTMENT 1.50 57.25 1.50 57.25
T N2 APARTMENT 2.75 51.75 2.75 51.75
T S1 APARTMENT 1.00 129.00 1.00 129.00
T S2 APARTMENT 0.50 128.00 0.50 128.00
G CORRIDOR 0.00 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
Facility 84.25 592.25 83.00 592.00
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.353 0.097 0.000 0.329
G NW APARTMENT 1.71 2.50 268.96 0.353 0.097 0.000 0.314
OFFICE 0.94 1.00 268.96 0.518 0.100 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.353 0.097 0.000 0.314
G N1 APARTMENT 1.71 2.50 268.96 0.353 0.058 0.000 0.307
G N2 APARTMENT 1.71 2.50 268.97 0.353 0.058 0.000 0.307
G S1 APARTMENT 1.71 2.50 268.96 0.353 0.058 0.000 0.325
G S2 APARTMENT 1.71 2.50 268.97 0.353 0.058 0.000 0.326
F2 SW APARTMENT 1.71 2.50 268.96 0.353 0.139 0.000 0.386
F2 NW APARTMENT 1.71 2.50 268.96 0.353 0.139 0.000 0.369
F2 SE APARTMENT 1.71 2.50 268.96 0.353 0.139 0.000 0.387
F2 NE APARTMENT 1.71 2.50 268.96 0.353 0.139 0.000 0.369
F2 N1 APARTMENT 1.71 2.50 268.96 0.353 0.084 0.000 0.365
F2 N2 APARTMENT 1.71 2.50 268.97 0.353 0.084 0.000 0.365
F2 S1 APARTMENT 1.71 2.50 268.96 0.354 0.084 0.000 0.385
F2 S2 APARTMENT 1.71 2.50 268.97 0.354 0.084 0.000 0.385
F3 SW APARTMENT 1.71 2.50 268.96 0.353 0.165 0.000 0.430
F3 NW APARTMENT 1.71 2.50 268.96 0.353 0.164 0.000 0.410
F3 SE APARTMENT 1.71 2.50 268.96 0.353 0.165 0.000 0.430
F3 NE APARTMENT 1.71 2.50 268.96 0.353 0.164 0.000 0.410
F3 N1 APARTMENT 1.71 2.50 268.96 0.353 0.099 0.000 0.406
F3 N2 APARTMENT 1.71 2.50 268.97 0.353 0.099 0.000 0.406
F3 S1 APARTMENT 1.71 2.50 268.96 0.354 0.099 0.000 0.428
F3 S2 APARTMENT 1.71 2.50 268.97 0.354 0.099 0.000 0.428
F4 SW APARTMENT 1.71 2.50 268.96 0.353 0.184 0.000 0.448
F4 NW APARTMENT 1.71 2.50 268.96 0.353 0.184 0.000 0.426
F4 SE APARTMENT 1.71 2.50 268.96 0.353 0.184 0.000 0.448
F4 NE APARTMENT 1.71 2.50 268.96 0.353 0.184 0.000 0.426
F4 N1 APARTMENT 1.71 2.50 268.96 0.353 0.111 0.000 0.423
F4 N2 APARTMENT 1.71 2.50 268.97 0.353 0.111 0.000 0.423
F4 S1 APARTMENT 1.71 2.50 268.96 0.354 0.111 0.000 0.447
F4 S2 APARTMENT 1.71 2.50 268.97 0.354 0.111 0.000 0.447
M SW APARTMENT 1.71 2.50 268.96 0.353 0.200 0.000 0.472
M NW APARTMENT 1.71 2.50 268.96 0.353 0.200 0.000 0.447
M SE APARTMENT 1.71 2.50 268.96 0.353 0.200 0.000 0.472
M NE APARTMENT 1.71 2.50 268.96 0.353 0.200 0.000 0.447
M N1 APARTMENT 1.71 2.50 268.96 0.353 0.120 0.000 0.445
M N2 APARTMENT 1.71 2.50 268.97 0.353 0.120 0.000 0.445
M S1 APARTMENT 1.71 2.50 268.96 0.354 0.121 0.000 0.470
M S2 APARTMENT 1.71 2.50 268.97 0.354 0.121 0.000 0.470
F6 SW APARTMENT 1.71 2.50 268.96 0.353 0.214 0.000 0.492
F6 NW APARTMENT 1.71 2.50 268.96 0.353 0.213 0.000 0.465
F6 SE APARTMENT 1.71 2.50 268.96 0.353 0.214 0.000 0.492
F6 NE APARTMENT 1.71 2.50 268.96 0.353 0.213 0.000 0.465
F6 N1 APARTMENT 1.71 2.50 268.96 0.353 0.129 0.000 0.462
F6 N2 APARTMENT 1.71 2.50 268.97 0.353 0.129 0.000 0.462
F6 S1 APARTMENT 1.71 2.50 268.96 0.354 0.129 0.000 0.490
F6 S2 APARTMENT 1.71 2.50 268.97 0.354 0.129 0.000 0.490
F7 SW APARTMENT 1.71 2.50 268.96 0.353 0.226 0.000 0.509
F7 NW APARTMENT 1.71 2.50 268.96 0.353 0.225 0.000 0.481
F7 SE APARTMENT 1.71 2.50 268.96 0.353 0.226 0.000 0.509
F7 NE APARTMENT 1.71 2.50 268.96 0.353 0.225 0.000 0.481
F7 N1 APARTMENT 1.71 2.50 268.96 0.353 0.136 0.000 0.478
F7 N2 APARTMENT 1.71 2.50 268.97 0.353 0.136 0.000 0.478
F7 S1 APARTMENT 1.71 2.50 268.96 0.354 0.136 0.000 0.507
F7 S2 APARTMENT 1.71 2.50 268.97 0.354 0.136 0.000 0.507
F8 SW APARTMENT 1.71 2.50 268.96 0.353 0.237 0.000 0.527
F8 NW APARTMENT 1.71 2.50 268.96 0.353 0.236 0.000 0.497
F8 SE APARTMENT 1.71 2.50 268.96 0.353 0.237 0.000 0.527
F8 NE APARTMENT 1.71 2.50 268.96 0.353 0.236 0.000 0.497
F8 N1 APARTMENT 1.71 2.50 268.96 0.353 0.142 0.000 0.494
F8 N2 APARTMENT 1.71 2.50 268.97 0.353 0.142 0.000 0.494
F8 S1 APARTMENT 1.71 2.50 268.96 0.354 0.143 0.000 0.525
F8 S2 APARTMENT 1.71 2.50 268.97 0.354 0.143 0.000 0.525
F9 SW APARTMENT 1.71 2.50 268.96 0.353 0.247 0.000 0.543
F9 NW APARTMENT 1.71 2.50 268.96 0.353 0.246 0.000 0.511
F9 SE APARTMENT 1.71 2.50 268.96 0.353 0.247 0.000 0.543
F9 NE APARTMENT 1.71 2.50 268.96 0.353 0.246 0.000 0.512
F9 N1 APARTMENT 1.71 2.50 268.96 0.353 0.148 0.000 0.508
F9 N2 APARTMENT 1.71 2.50 268.97 0.353 0.148 0.000 0.508
F9 S1 APARTMENT 1.71 2.50 268.96 0.353 0.149 0.000 0.541
F9 S2 APARTMENT 1.71 2.50 268.97 0.353 0.149 0.000 0.541
T SW APARTMENT 1.71 2.50 268.96 0.353 0.256 0.000 0.555
T NW APARTMENT 1.71 2.50 268.96 0.353 0.255 0.000 0.523
T SE APARTMENT 1.71 2.50 268.96 0.353 0.256 0.000 0.555
T NE APARTMENT 1.71 2.50 268.96 0.352 0.255 0.000 0.523
T N1 APARTMENT 1.71 2.50 268.96 0.353 0.154 0.000 0.520
T N2 APARTMENT 1.71 2.50 268.97 0.353 0.154 0.000 0.520
T S1 APARTMENT 1.71 2.50 268.96 0.353 0.154 0.000 0.553
T S2 APARTMENT 1.71 2.50 268.97 0.353 0.154 0.000 0.553
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
OFFICE 0.94 1.00 268.96 0.504 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F2 SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F2 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F2 SE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F2 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F2 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F2 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F2 S1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F2 S2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
F3 SW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F3 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F3 SE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F3 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F3 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F3 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F3 S1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F3 S2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
F4 SW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F4 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F4 SE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F4 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F4 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F4 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F4 S1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F4 S2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
F6 SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F6 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F6 SE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F6 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F6 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F6 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F6 S1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F6 S2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
F7 SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F7 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F7 SE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F7 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F7 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F7 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F7 S1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F7 S2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
F8 SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F8 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F8 SE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F8 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F8 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F8 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F8 S1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F8 S2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
F9 SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F9 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F9 SE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F9 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F9 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F9 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F9 S1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F9 S2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Surfaces by Class

Total Outdoors
Wall 420 140
Floor 90 9
Roof 90 9
Internal Mass 80 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 140 140
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 80
Conditioned Zones 80
Unconditioned Zones 10
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 4197
Defaulted Fields 814
Fields with Defaults 11307
Autosized Fields 1293
Autosizable Fields 1630
Autocalculated Fields 907
Autocalculatable Fields 1710



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 3081.65 60126.71 19-APR-03:00 171347.37 21-JUL-19:15
Electricity:Building 1547.51 26803.46 01-JAN-03:15 79071.91 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity 416.41 7980.64 01-JAN-00:15 25049.15 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 348.50 6974.01 01-JAN-00:15 20603.34 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:OFFICE 29.50 508.27 01-JAN-00:15 2167.24 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 21.95 379.58 01-JAN-00:15 1622.33 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:G CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:F2 SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:F2 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:F3 SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:F3 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:F4 SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:F4 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:M SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M CORRIDOR 37.06 1175.12 01-JAN-00:15 1175.12 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 37.06 1175.12 01-JAN-00:15 1175.12 01-JAN-00:15
Electricity:Zone:F6 SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:F6 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:F7 SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:F7 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:F8 SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:F8 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:F9 SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:F9 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:T SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T CORRIDOR 177.27 1611.36 01-JAN-00:15 10825.51 01-JAN-07:15
InteriorLights:Electricity:Zone:T CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 67.92 1006.63 01-JAN-00:15 4445.81 01-JAN-19:15
InteriorEquipment:Electricity 1131.09 18822.82 01-JAN-03:15 56933.81 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 1131.09 18822.82 01-JAN-03:15 56933.81 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 7.55 128.69 01-JAN-00:15 544.91 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T CORRIDOR 158.74 1023.79 01-JAN-00:15 10237.95 01-JAN-07:15
Fans:Electricity 699.65 22185.69 02-JAN-06:15 22185.69 01-JAN-00:15
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Electricity:HVAC 1302.99 22566.22 19-APR-03:00 85973.28 31-JUL-16:30
ElectricityProduced:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityProduced:HVAC 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricityProduced 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 3081.65 60126.71 19-APR-03:00 171347.37 21-JUL-19:15
ElectricityPurchased:Plant 3081.65 60126.71 19-APR-03:00 171347.37 21-JUL-19:15
Cogeneration:ElectricityPurchased 3081.65 60126.71 19-APR-03:00 171347.37 21-JUL-19:15
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 3081.65 60126.71 19-APR-03:00 171347.37 21-JUL-19:15
ElectricityNet:Plant 3081.65 60126.71 19-APR-03:00 171347.37 21-JUL-19:15
Cogeneration:ElectricityNet 3081.65 60126.71 19-APR-03:00 171347.37 21-JUL-19:15
ExteriorLights:Electricity 168.44 0.00 01-JAN-07:30 10720.10 01-JAN-00:15
General:ExteriorLights:Electricity 168.44 0.00 01-JAN-07:30 10720.10 01-JAN-00:15
General:Fans:Electricity 699.65 22185.69 02-JAN-06:15 22185.69 01-JAN-00:15
Cooling:Electricity 543.05 0.00 01-JAN-00:15 62737.86 21-JUL-15:30
Heating:Electricity 39.47 0.00 01-JAN-12:30 27969.25 18-JAN-01:30
Electricity:Plant 62.72 36.93 02-MAR-14:00 3552.87 31-JUL-15:00
HeatRejection:Electricity 19.13 0.00 01-JAN-00:15 2159.84 31-JUL-15:00
Boiler Parasitic:Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Pumps:Electricity 43.59 36.93 02-MAR-14:00 1393.03 01-JAN-00:15
WIRED_LTG_ELECTRICITY 0.62 0.00 01-JAN-00:15 37.57 01-JAN-19:30
WIRED_INT_EQUIP 973.17 1018.50 01-JAN-00:15 10185.00 01-JAN-07:15


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 1193.04 9260.51 01-JAN-00:15 174185.85 17-JAN-08:00
Gas:Plant 1193.04 9260.51 01-JAN-00:15 174185.85 17-JAN-08:00
WaterSystems:Gas 1107.29 9260.51 01-JAN-00:15 87083.60 05-FEB-08:00
Water Heater:WaterSystems:Gas 1107.29 9260.51 01-JAN-00:15 87083.60 05-FEB-08:00
Heating:Gas 85.75 0.00 01-JAN-00:15 101426.39 18-JAN-01:45
Boiler:Heating:Gas 85.75 0.00 01-JAN-00:15 101426.39 18-JAN-01:45


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
PlantLoopCoolingDemand:Facility 2163.57 0.00 01-JAN-00:15 281617.38 31-JUL-16:30
PlantLoopCoolingDemand:HVAC 2163.57 0.00 01-JAN-00:15 281617.38 31-JUL-16:30
CoolingCoils:PlantLoopCoolingDemand 2163.57 0.00 01-JAN-00:15 281617.38 31-JUL-16:30


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 6602.18 0.00 01-JAN-02:15 0.00 21-JUL-17:15
Water:Plant 6602.18 0.00 01-JAN-02:15 0.00 21-JUL-17:15
WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
MainsWater:Facility 6602.18 0.00 01-JAN-02:15 0.00 21-JUL-17:15
MainsWater:Plant 6602.18 0.00 01-JAN-02:15 0.00 21-JUL-17:15
WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
sub cat:WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
sub cat:WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
HeatRejection:Water 1823.67 0.00 01-JAN-00:15 0.00 28-JUN-16:00
HeatRejection:MainsWater 1823.67 0.00 01-JAN-00:15 0.00 28-JUN-16:00


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 950.23 445.40 08-AUG-01:15 130319.55 17-JAN-08:00
PlantLoopHeatingDemand:Plant 841.13 445.40 08-AUG-01:15 58322.72 08-FEB-07:45
WaterSystems:PlantLoopHeatingDemand 841.13 445.40 08-AUG-01:15 58322.72 08-FEB-07:45
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 4320.35 6208.78 10-JUN-03:00 421892.42 20-AUG-17:15
EnergyTransfer:Building 1612.33 4559.57 28-MAR-13:45 174874.27 20-AUG-17:15
EnergyTransfer:Zone:G SW APARTMENT 15.23 0.01 03-MAR-08:00 2487.78 28-SEP-16:30
Heating:EnergyTransfer 94.71 0.00 03-JAN-21:00 80985.99 18-JAN-01:30
Heating:EnergyTransfer:Zone:G SW APARTMENT 1.04 0.00 01-JAN-00:15 1024.31 18-JAN-01:30
Cooling:EnergyTransfer 1517.62 0.00 17-JAN-08:15 174874.27 20-AUG-17:15
Cooling:EnergyTransfer:Zone:G SW APARTMENT 14.19 0.00 01-JAN-03:00 2487.78 28-SEP-16:30
EnergyTransfer:Zone:G NW APARTMENT 12.09 0.00 18-FEB-17:00 2342.32 25-JUN-17:30
Heating:EnergyTransfer:Zone:G NW APARTMENT 2.97 0.00 01-JAN-17:15 1128.29 17-JAN-08:15
Cooling:EnergyTransfer:Zone:G NW APARTMENT 9.12 0.00 01-JAN-00:15 2342.32 25-JUN-17:30
EnergyTransfer:Zone:OFFICE 22.23 0.02 01-APR-21:45 3084.86 12-SEP-12:30
Heating:EnergyTransfer:Zone:OFFICE 1.00 0.00 01-JAN-00:15 1090.71 17-JAN-08:00
Cooling:EnergyTransfer:Zone:OFFICE 21.23 0.00 01-JAN-02:00 3084.86 12-SEP-12:30
EnergyTransfer:Zone:G NE APARTMENT 12.41 0.04 11-AUG-06:45 1726.37 28-JUN-08:15
Heating:EnergyTransfer:Zone:G NE APARTMENT 2.63 0.00 01-JAN-08:30 1170.53 14-DEC-04:00
Cooling:EnergyTransfer:Zone:G NE APARTMENT 9.78 0.00 01-JAN-00:15 1726.37 28-JUN-08:15
EnergyTransfer:Zone:G N1 APARTMENT 8.47 0.01 07-NOV-04:15 1226.99 11-JUN-18:30
Heating:EnergyTransfer:Zone:G N1 APARTMENT 1.12 0.00 01-JAN-10:30 790.14 19-FEB-16:15
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 7.35 0.00 01-JAN-00:15 1226.99 11-JUN-18:30
EnergyTransfer:Zone:G N2 APARTMENT 8.48 0.00 27-FEB-08:45 1206.02 11-JUN-18:30
Heating:EnergyTransfer:Zone:G N2 APARTMENT 1.11 0.00 01-JAN-10:15 792.45 19-FEB-16:15
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 7.37 0.00 01-JAN-00:15 1206.02 11-JUN-18:30
EnergyTransfer:Zone:G S1 APARTMENT 13.07 0.02 21-MAY-01:00 1425.83 29-SEP-11:30
Heating:EnergyTransfer:Zone:G S1 APARTMENT 0.14 0.00 01-JAN-00:15 488.28 18-JAN-01:30
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 12.94 0.00 11-JAN-05:15 1425.83 29-SEP-11:30
EnergyTransfer:Zone:G S2 APARTMENT 13.29 0.03 27-APR-09:45 1482.84 29-SEP-11:30
Heating:EnergyTransfer:Zone:G S2 APARTMENT 0.14 0.00 01-JAN-00:15 479.49 18-JAN-01:30
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 13.15 0.00 13-JAN-04:00 1482.84 29-SEP-11:30
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F2 SW APARTMENT 25.03 0.08 25-MAY-03:45 3212.00 11-OCT-15:15
Heating:EnergyTransfer:Zone:F2 SW APARTMENT 0.45 0.00 01-JAN-00:15 1012.59 18-JAN-02:00
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT 24.58 0.00 12-JAN-06:00 3212.00 11-OCT-15:15
EnergyTransfer:Zone:F2 NW APARTMENT 16.86 0.00 19-MAR-19:45 2999.19 25-JUN-17:30
Heating:EnergyTransfer:Zone:F2 NW APARTMENT 1.98 0.00 01-JAN-10:00 1226.55 14-DEC-04:00
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT 14.88 0.00 01-JAN-00:15 2999.19 25-JUN-17:30
EnergyTransfer:Zone:F2 SE APARTMENT 27.05 0.04 08-DEC-09:15 2867.21 01-OCT-11:15
Heating:EnergyTransfer:Zone:F2 SE APARTMENT 0.32 0.00 01-JAN-00:15 982.71 18-JAN-02:00
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT 26.73 0.00 01-JAN-15:45 2867.21 01-OCT-11:15
EnergyTransfer:Zone:F2 NE APARTMENT 17.82 0.02 15-MAR-19:15 2303.48 28-JUN-08:15
Heating:EnergyTransfer:Zone:F2 NE APARTMENT 1.77 0.00 01-JAN-07:45 1324.20 14-DEC-04:00
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT 16.06 0.00 01-JAN-00:15 2303.48 28-JUN-08:15
EnergyTransfer:Zone:F2 N1 APARTMENT 12.73 0.01 19-FEB-13:30 1656.05 11-JUN-18:30
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT 0.47 0.00 01-JAN-00:15 753.02 19-FEB-16:15
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT 12.27 0.00 01-JAN-02:00 1656.05 11-JUN-18:30
EnergyTransfer:Zone:F2 N2 APARTMENT 12.77 0.00 04-JUN-06:30 1639.07 11-JUN-18:30
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT 0.47 0.00 01-JAN-00:15 757.11 19-FEB-16:15
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT 12.30 0.00 01-JAN-02:00 1639.07 11-JUN-18:30
EnergyTransfer:Zone:F2 S1 APARTMENT 22.18 0.09 09-MAR-14:15 2100.14 01-NOV-12:30
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT 0.08 0.00 01-JAN-00:15 385.67 18-JAN-02:00
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT 22.10 0.00 17-JAN-02:30 2100.14 01-NOV-12:30
EnergyTransfer:Zone:F2 S2 APARTMENT 22.31 0.05 29-AUG-06:30 2117.81 01-NOV-12:30
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT 0.08 0.00 01-JAN-00:15 383.49 18-JAN-02:00
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT 22.23 0.00 17-JAN-02:30 2117.81 01-NOV-12:30
EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F3 SW APARTMENT 26.78 0.01 20-MAR-19:45 3242.79 10-OCT-16:00
Heating:EnergyTransfer:Zone:F3 SW APARTMENT 0.39 0.00 01-JAN-00:15 1035.22 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT 26.38 0.00 16-JAN-21:00 3242.79 10-OCT-16:00
EnergyTransfer:Zone:F3 NW APARTMENT 17.75 0.04 03-JAN-11:00 3017.74 22-JUL-17:30
Heating:EnergyTransfer:Zone:F3 NW APARTMENT 1.76 0.00 01-JAN-00:15 1324.73 14-DEC-04:00
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT 15.99 0.00 01-JAN-01:15 3017.74 22-JUL-17:30
EnergyTransfer:Zone:F3 SE APARTMENT 27.93 0.16 19-OCT-19:15 2728.66 01-OCT-10:45
Heating:EnergyTransfer:Zone:F3 SE APARTMENT 0.29 0.00 01-JAN-00:15 1048.95 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT 27.64 0.00 01-JAN-15:45 2728.66 01-OCT-10:45
EnergyTransfer:Zone:F3 NE APARTMENT 18.82 0.00 05-NOV-13:15 2346.49 28-JUN-08:15
Heating:EnergyTransfer:Zone:F3 NE APARTMENT 1.59 0.00 01-JAN-07:30 1424.37 14-DEC-04:00
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT 17.23 0.00 01-JAN-00:15 2346.49 28-JUN-08:15
EnergyTransfer:Zone:F3 N1 APARTMENT 13.91 0.09 09-SEP-09:15 1726.89 07-JUN-18:00
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT 0.37 0.00 01-JAN-00:15 800.13 19-FEB-16:15
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT 13.54 0.00 01-JAN-03:00 1726.89 07-JUN-18:00
EnergyTransfer:Zone:F3 N2 APARTMENT 13.95 0.01 04-JUN-20:45 1713.63 07-JUN-18:00
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT 0.37 0.00 01-JAN-00:15 807.43 19-FEB-16:15
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT 13.58 0.00 01-JAN-03:00 1713.63 07-JUN-18:00
EnergyTransfer:Zone:F3 S1 APARTMENT 24.47 0.46 29-AUG-06:30 2169.79 29-DEC-12:45
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT 0.07 0.00 01-JAN-00:15 382.20 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT 24.39 0.00 17-JAN-08:15 2169.79 29-DEC-12:45
EnergyTransfer:Zone:F3 S2 APARTMENT 24.53 0.16 29-AUG-06:45 2177.04 29-DEC-12:45
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT 0.08 0.00 01-JAN-00:15 382.95 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT 24.45 0.00 17-JAN-08:15 2177.04 29-DEC-12:45
EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F4 SW APARTMENT 27.04 0.04 02-MAR-00:15 3266.89 10-OCT-16:00
Heating:EnergyTransfer:Zone:F4 SW APARTMENT 0.41 0.00 01-JAN-00:15 1100.60 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT 26.64 0.00 16-JAN-18:00 3266.89 10-OCT-16:00
EnergyTransfer:Zone:F4 NW APARTMENT 18.01 0.01 03-MAR-16:00 3032.50 22-JUL-17:30
Heating:EnergyTransfer:Zone:F4 NW APARTMENT 1.78 0.00 01-JAN-00:15 1437.42 14-DEC-04:00
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT 16.22 0.00 01-JAN-01:15 3032.50 22-JUL-17:30
EnergyTransfer:Zone:F4 SE APARTMENT 28.08 0.12 22-MAR-12:45 2729.14 01-OCT-10:45
Heating:EnergyTransfer:Zone:F4 SE APARTMENT 0.31 0.00 01-JAN-00:15 1120.67 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT 27.77 0.00 01-JAN-15:45 2729.14 01-OCT-10:45
EnergyTransfer:Zone:F4 NE APARTMENT 19.10 0.01 20-NOV-12:30 2371.73 28-JUN-08:15
Heating:EnergyTransfer:Zone:F4 NE APARTMENT 1.62 0.00 01-JAN-07:30 1532.93 14-DEC-04:00
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT 17.47 0.00 01-JAN-00:15 2371.73 28-JUN-08:15
EnergyTransfer:Zone:F4 N1 APARTMENT 14.28 0.01 23-SEP-21:00 1746.24 23-JUN-21:00
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT 0.38 0.00 01-JAN-00:15 901.10 19-FEB-16:15
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT 13.91 0.00 01-JAN-05:00 1746.24 23-JUN-21:00
EnergyTransfer:Zone:F4 N2 APARTMENT 14.32 0.02 29-JAN-04:15 1731.76 23-JUN-21:00
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT 0.38 0.00 01-JAN-00:15 909.64 19-FEB-16:15
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT 13.94 0.00 01-JAN-03:15 1731.76 23-JUN-21:00
EnergyTransfer:Zone:F4 S1 APARTMENT 25.00 0.22 11-OCT-09:30 2187.23 29-DEC-12:45
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT 0.08 0.00 01-JAN-00:15 410.54 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT 24.92 0.00 17-JAN-08:15 2187.23 29-DEC-12:45
EnergyTransfer:Zone:F4 S2 APARTMENT 25.04 0.11 04-JUN-19:00 2192.65 29-DEC-12:45
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT 0.08 0.00 01-JAN-00:15 411.93 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT 24.95 0.00 17-JAN-08:15 2192.65 29-DEC-12:45
EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M SW APARTMENT 27.32 0.04 09-JUN-03:15 3311.14 10-OCT-16:00
Heating:EnergyTransfer:Zone:M SW APARTMENT 0.43 0.00 01-JAN-00:15 1156.58 18-JAN-01:30
Cooling:EnergyTransfer:Zone:M SW APARTMENT 26.89 0.00 16-JAN-17:45 3311.14 10-OCT-16:00
EnergyTransfer:Zone:M NW APARTMENT 18.36 0.00 07-DEC-16:45 3063.85 22-JUL-17:30
Heating:EnergyTransfer:Zone:M NW APARTMENT 1.82 0.00 01-JAN-00:15 1525.08 14-DEC-04:00
Cooling:EnergyTransfer:Zone:M NW APARTMENT 16.53 0.00 01-JAN-01:15 3063.85 22-JUL-17:30
EnergyTransfer:Zone:M SE APARTMENT 28.35 0.00 18-MAY-04:15 2760.88 01-OCT-11:00
Heating:EnergyTransfer:Zone:M SE APARTMENT 0.34 0.00 01-JAN-00:15 1176.58 18-JAN-01:30
Cooling:EnergyTransfer:Zone:M SE APARTMENT 28.01 0.00 01-JAN-15:30 2760.88 01-OCT-11:00
EnergyTransfer:Zone:M NE APARTMENT 19.44 0.00 01-MAR-12:15 2412.03 28-JUN-08:15
Heating:EnergyTransfer:Zone:M NE APARTMENT 1.65 0.00 01-JAN-07:30 1616.15 14-DEC-04:00
Cooling:EnergyTransfer:Zone:M NE APARTMENT 17.79 0.00 01-JAN-00:15 2412.03 28-JUN-08:15
EnergyTransfer:Zone:M N1 APARTMENT 14.70 0.06 19-FEB-13:30 1793.16 23-JUN-21:00
Heating:EnergyTransfer:Zone:M N1 APARTMENT 0.38 0.00 01-JAN-00:15 994.49 19-FEB-16:15
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 14.31 0.00 01-JAN-14:00 1793.16 23-JUN-21:00
EnergyTransfer:Zone:M N2 APARTMENT 14.73 0.24 30-JAN-14:30 1778.71 23-JUN-21:00
Heating:EnergyTransfer:Zone:M N2 APARTMENT 0.38 0.00 01-JAN-00:15 1002.97 19-FEB-16:15
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 14.35 0.00 01-JAN-05:15 1778.71 23-JUN-21:00
EnergyTransfer:Zone:M S1 APARTMENT 25.45 0.12 30-MAR-15:15 2220.48 29-DEC-12:45
Heating:EnergyTransfer:Zone:M S1 APARTMENT 0.09 0.00 01-JAN-00:15 435.75 18-JAN-01:30
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 25.36 0.00 05-JAN-15:00 2220.48 29-DEC-12:45
EnergyTransfer:Zone:M S2 APARTMENT 25.49 0.10 15-OCT-20:45 2225.47 29-DEC-12:45
Heating:EnergyTransfer:Zone:M S2 APARTMENT 0.09 0.00 01-JAN-00:15 437.25 18-JAN-01:30
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 25.39 0.00 05-JAN-15:00 2225.47 29-DEC-12:45
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F6 SW APARTMENT 26.20 0.04 02-MAR-16:45 3278.89 10-OCT-16:00
Heating:EnergyTransfer:Zone:F6 SW APARTMENT 0.51 0.00 01-JAN-00:15 1253.90 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT 25.69 0.00 05-JAN-15:00 3278.89 10-OCT-16:00
EnergyTransfer:Zone:F6 NW APARTMENT 17.92 0.00 26-JAN-16:45 3019.77 22-JUL-17:30
Heating:EnergyTransfer:Zone:F6 NW APARTMENT 2.14 0.00 01-JAN-09:00 1657.31 14-DEC-04:00
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT 15.78 0.00 01-JAN-00:15 3019.77 22-JUL-17:30
EnergyTransfer:Zone:F6 SE APARTMENT 27.21 0.03 02-FEB-02:45 2726.32 01-OCT-11:00
Heating:EnergyTransfer:Zone:F6 SE APARTMENT 0.41 0.00 01-JAN-00:15 1275.03 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT 26.80 0.00 01-JAN-15:15 2726.32 01-OCT-11:00
EnergyTransfer:Zone:F6 NE APARTMENT 18.93 0.03 17-DEC-16:30 2379.49 28-JUN-08:15
Heating:EnergyTransfer:Zone:F6 NE APARTMENT 1.94 0.00 01-JAN-07:30 1748.61 14-DEC-04:00
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT 16.99 0.00 01-JAN-00:15 2379.49 28-JUN-08:15
EnergyTransfer:Zone:F6 N1 APARTMENT 14.05 0.06 24-DEC-11:00 1766.38 23-JUN-21:00
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT 0.48 0.00 01-JAN-00:15 1178.75 19-FEB-16:15
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT 13.57 0.00 01-JAN-02:45 1766.38 23-JUN-21:00
EnergyTransfer:Zone:F6 N2 APARTMENT 14.09 0.06 18-JUN-05:45 1752.02 23-JUN-21:00
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT 0.48 0.00 01-JAN-00:15 1185.19 19-FEB-16:15
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT 13.61 0.00 01-JAN-02:30 1752.02 23-JUN-21:00
EnergyTransfer:Zone:F6 S1 APARTMENT 24.34 0.21 25-SEP-08:15 2180.81 29-DEC-13:00
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT 0.11 0.00 01-JAN-00:15 509.72 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT 24.23 0.00 05-JAN-15:00 2180.81 29-DEC-13:00
EnergyTransfer:Zone:F6 S2 APARTMENT 24.38 0.12 30-APR-09:45 2185.58 29-DEC-12:45
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT 0.11 0.00 01-JAN-00:15 511.07 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT 24.26 0.00 05-JAN-15:00 2185.58 29-DEC-12:45
EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F7 SW APARTMENT 25.55 0.02 02-MAR-09:45 3269.59 10-OCT-16:00
Heating:EnergyTransfer:Zone:F7 SW APARTMENT 0.59 0.00 01-JAN-00:15 1335.55 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT 24.96 0.00 05-JAN-14:45 3269.59 10-OCT-16:00
EnergyTransfer:Zone:F7 NW APARTMENT 17.78 0.00 15-APR-13:00 3004.41 22-JUL-17:30
Heating:EnergyTransfer:Zone:F7 NW APARTMENT 2.39 0.00 01-JAN-10:15 1765.17 14-DEC-04:00
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT 15.39 0.00 01-JAN-00:15 3004.41 22-JUL-17:30
EnergyTransfer:Zone:F7 SE APARTMENT 26.55 0.32 06-MAY-23:45 2714.55 01-OCT-11:00
Heating:EnergyTransfer:Zone:F7 SE APARTMENT 0.48 0.00 01-JAN-00:15 1357.37 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT 26.07 0.00 01-JAN-15:00 2714.55 01-OCT-11:00
EnergyTransfer:Zone:F7 NE APARTMENT 18.76 0.01 19-FEB-11:45 2373.24 28-JUN-08:15
Heating:EnergyTransfer:Zone:F7 NE APARTMENT 2.19 0.00 01-JAN-07:45 1853.90 14-DEC-04:00
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT 16.57 0.00 01-JAN-00:15 2373.24 28-JUN-08:15
EnergyTransfer:Zone:F7 N1 APARTMENT 13.76 0.09 23-FEB-05:30 1764.18 23-JUN-21:00
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT 0.57 0.00 01-JAN-00:15 1240.38 17-MAR-15:00
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT 13.19 0.00 01-JAN-02:15 1764.18 23-JUN-21:00
EnergyTransfer:Zone:F7 N2 APARTMENT 13.79 0.02 11-DEC-10:00 1749.89 23-JUN-21:00
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT 0.57 0.00 01-JAN-00:15 1237.45 19-FEB-16:00
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT 13.22 0.00 01-JAN-02:15 1749.89 23-JUN-21:00
EnergyTransfer:Zone:F7 S1 APARTMENT 23.70 0.07 24-AUG-08:15 2165.87 29-DEC-13:00
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT 0.13 0.00 01-JAN-00:15 564.97 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT 23.57 0.00 05-JAN-14:45 2165.87 29-DEC-13:00
EnergyTransfer:Zone:F7 S2 APARTMENT 23.73 0.08 14-APR-09:15 2170.42 29-DEC-13:00
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT 0.13 0.00 01-JAN-00:15 566.06 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT 23.60 0.00 05-JAN-14:45 2170.42 29-DEC-13:00
EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F8 SW APARTMENT 25.05 0.02 04-MAY-00:15 3274.38 10-OCT-16:00
Heating:EnergyTransfer:Zone:F8 SW APARTMENT 0.68 0.00 01-JAN-00:15 1422.76 18-JAN-01:15
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT 24.37 0.00 01-JAN-15:45 3274.38 10-OCT-16:00
EnergyTransfer:Zone:F8 NW APARTMENT 17.83 0.04 30-NOV-19:00 3005.49 22-JUL-17:30
Heating:EnergyTransfer:Zone:F8 NW APARTMENT 2.67 0.00 01-JAN-10:15 1865.43 14-DEC-04:00
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT 15.16 0.00 01-JAN-00:15 3005.49 22-JUL-17:30
EnergyTransfer:Zone:F8 SE APARTMENT 26.05 0.09 09-NOV-05:45 2716.21 01-OCT-11:00
Heating:EnergyTransfer:Zone:F8 SE APARTMENT 0.56 0.00 01-JAN-00:15 1445.04 18-JAN-01:15
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT 25.48 0.00 01-JAN-14:45 2716.21 01-OCT-11:00
EnergyTransfer:Zone:F8 NE APARTMENT 18.75 0.01 01-DEC-06:00 2377.51 28-JUN-08:15
Heating:EnergyTransfer:Zone:F8 NE APARTMENT 2.43 0.00 01-JAN-07:45 1952.41 14-DEC-04:00
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT 16.32 0.00 01-JAN-00:15 2377.51 28-JUN-08:15
EnergyTransfer:Zone:F8 N1 APARTMENT 13.63 0.00 16-DEC-14:30 1776.36 23-JUN-21:00
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT 0.68 0.00 01-JAN-00:15 1431.12 17-MAR-15:00
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT 12.95 0.00 01-JAN-02:00 1776.36 23-JUN-21:00
EnergyTransfer:Zone:F8 N2 APARTMENT 13.67 0.02 19-DEC-01:30 1762.15 23-JUN-21:00
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT 0.68 0.00 01-JAN-00:15 1424.75 17-MAR-15:00
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT 12.99 0.00 01-JAN-02:00 1762.15 23-JUN-21:00
EnergyTransfer:Zone:F8 S1 APARTMENT 23.16 0.15 09-SEP-09:30 2161.31 29-DEC-13:00
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT 0.15 0.00 01-JAN-00:15 618.66 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT 23.01 0.00 01-JAN-15:30 2161.31 29-DEC-13:00
EnergyTransfer:Zone:F8 S2 APARTMENT 23.20 0.00 15-OCT-20:45 2165.75 29-DEC-13:00
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT 0.15 0.00 01-JAN-00:15 619.77 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT 23.05 0.00 01-JAN-15:30 2165.75 29-DEC-13:00
EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F9 SW APARTMENT 24.63 0.05 05-MAY-20:45 3391.00 10-OCT-15:45
Heating:EnergyTransfer:Zone:F9 SW APARTMENT 0.91 0.00 01-JAN-00:15 1589.94 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT 23.72 0.00 01-JAN-15:30 3391.00 10-OCT-15:45
EnergyTransfer:Zone:F9 NW APARTMENT 18.53 0.04 09-OCT-01:45 3116.37 22-JUL-17:30
Heating:EnergyTransfer:Zone:F9 NW APARTMENT 3.29 0.00 01-JAN-10:30 2005.93 14-DEC-04:00
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT 15.25 0.00 01-JAN-00:15 3116.37 22-JUL-17:30
EnergyTransfer:Zone:F9 SE APARTMENT 25.61 0.01 21-DEC-02:45 2790.58 10-OCT-15:45
Heating:EnergyTransfer:Zone:F9 SE APARTMENT 0.78 0.00 01-JAN-00:15 1611.62 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT 24.83 0.00 01-JAN-14:15 2790.58 10-OCT-15:45
EnergyTransfer:Zone:F9 NE APARTMENT 19.29 0.00 26-OCT-15:00 2416.76 28-JUN-08:15
Heating:EnergyTransfer:Zone:F9 NE APARTMENT 2.96 0.00 01-JAN-08:00 2098.90 14-DEC-04:00
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT 16.33 0.00 01-JAN-00:15 2416.76 28-JUN-08:15
EnergyTransfer:Zone:F9 N1 APARTMENT 13.85 0.11 24-FEB-08:45 1879.83 23-JUN-21:00
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT 0.97 0.00 01-JAN-00:15 1627.86 17-MAR-15:00
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT 12.88 0.00 01-JAN-01:30 1879.83 23-JUN-21:00
EnergyTransfer:Zone:F9 N2 APARTMENT 13.88 0.03 07-JAN-10:00 1865.35 23-JUN-21:00
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT 0.97 0.00 01-JAN-00:15 1619.39 17-MAR-15:00
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT 12.92 0.00 01-JAN-01:30 1865.35 23-JUN-21:00
EnergyTransfer:Zone:F9 S1 APARTMENT 22.53 0.42 03-JUN-09:00 2179.64 07-NOV-11:45
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT 0.20 0.00 01-JAN-00:15 728.39 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT 22.32 0.00 01-JAN-15:00 2179.64 07-NOV-11:45
EnergyTransfer:Zone:F9 S2 APARTMENT 22.57 0.13 26-MAY-20:15 2188.38 07-NOV-11:45
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT 0.21 0.00 01-JAN-00:15 729.61 18-JAN-01:30
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT 22.37 0.00 01-JAN-15:00 2188.38 07-NOV-11:45
EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:T SW APARTMENT 28.83 0.05 26-DEC-20:45 4134.36 10-OCT-15:45
Heating:EnergyTransfer:Zone:T SW APARTMENT 4.35 0.00 01-JAN-08:15 2195.28 17-JAN-04:00
Cooling:EnergyTransfer:Zone:T SW APARTMENT 24.47 0.00 01-JAN-00:15 4134.36 10-OCT-15:45
EnergyTransfer:Zone:T NW APARTMENT 23.92 0.00 28-DEC-15:30 3845.25 18-JUL-16:45
Heating:EnergyTransfer:Zone:T NW APARTMENT 7.50 0.00 02-JAN-14:15 2635.33 14-DEC-04:00
Cooling:EnergyTransfer:Zone:T NW APARTMENT 16.42 0.00 01-JAN-00:15 3845.25 18-JUL-16:45
EnergyTransfer:Zone:T SE APARTMENT 28.97 0.02 04-NOV-22:00 3588.54 01-OCT-12:00
Heating:EnergyTransfer:Zone:T SE APARTMENT 3.99 0.00 01-JAN-07:45 2217.23 17-JAN-04:00
Cooling:EnergyTransfer:Zone:T SE APARTMENT 24.97 0.00 01-JAN-00:15 3588.54 01-OCT-12:00
EnergyTransfer:Zone:T NE APARTMENT 23.57 0.00 23-APR-10:45 3012.35 28-JUN-08:15
Heating:EnergyTransfer:Zone:T NE APARTMENT 6.73 0.00 01-JAN-08:45 2684.09 14-DEC-04:00
Cooling:EnergyTransfer:Zone:T NE APARTMENT 16.83 0.00 01-JAN-00:15 3012.35 28-JUN-08:15
EnergyTransfer:Zone:T N1 APARTMENT 16.44 0.00 27-MAY-02:00 2384.35 23-JUN-21:00
Heating:EnergyTransfer:Zone:T N1 APARTMENT 3.45 0.00 01-JAN-10:00 1869.38 17-MAR-15:00
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 13.00 0.00 01-JAN-00:15 2384.35 23-JUN-21:00
EnergyTransfer:Zone:T N2 APARTMENT 16.50 0.01 13-JAN-16:00 2380.35 23-JUN-21:00
Heating:EnergyTransfer:Zone:T N2 APARTMENT 3.47 0.00 01-JAN-10:00 1862.49 17-MAR-15:00
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 13.04 0.00 01-JAN-00:15 2380.35 23-JUN-21:00
EnergyTransfer:Zone:T S1 APARTMENT 23.10 0.01 03-NOV-23:45 2931.13 07-NOV-12:45
Heating:EnergyTransfer:Zone:T S1 APARTMENT 1.38 0.00 01-JAN-00:15 1443.18 09-NOV-16:45
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 21.73 0.00 01-JAN-02:45 2931.13 07-NOV-12:45
EnergyTransfer:Zone:T S2 APARTMENT 23.15 0.05 11-APR-03:30 2943.00 07-NOV-12:45
Heating:EnergyTransfer:Zone:T S2 APARTMENT 1.38 0.00 01-JAN-00:15 1441.80 09-NOV-16:45
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 21.77 0.00 01-JAN-02:45 2943.00 07-NOV-12:45
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Plant 909.56 445.40 08-AUG-01:15 127712.13 17-JAN-08:00
WaterSystems:EnergyTransfer 841.12 445.40 08-AUG-01:15 58316.75 08-FEB-07:45
sub cat:WaterSystems:EnergyTransfer 841.12 445.40 08-AUG-01:15 58316.75 08-FEB-07:45
EnergyTransfer:HVAC 1798.46 0.00 02-MAR-14:00 219388.79 31-JUL-16:45
CoolingCoils:EnergyTransfer 1656.38 0.00 01-JAN-00:15 219388.79 31-JUL-16:45
HeatingCoils:EnergyTransfer 142.08 0.00 01-JAN-12:30 107781.56 18-JAN-01:30
PlantLoopHeatingDemand:HVAC 109.10 0.00 01-JAN-12:30 82437.39 18-JAN-01:30
HeatingCoils:PlantLoopHeatingDemand 109.10 0.00 01-JAN-12:30 82437.39 18-JAN-01:30
Boilers:EnergyTransfer 68.44 0.00 01-JAN-00:15 81141.11 18-JAN-01:45



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 1.039 -14.193 0.000 0.000 3.722 2.413 12.213 27.859 0.000 0.284 0.001 0.000 -9.884 0.000 -5.245 -18.209
G NW APARTMENT 2.969 -9.121 0.000 0.000 3.786 2.413 12.213 14.033 0.000 0.278 0.000 0.000 -9.897 0.000 -4.838 -11.836
OFFICE 0.997 -21.233 0.000 0.000 0.509 21.954 7.547 28.561 0.000 0.166 0.000 0.000 -9.682 0.000 -2.232 -26.586
G NE APARTMENT 2.628 -9.785 0.000 0.000 3.803 2.413 12.213 14.565 0.000 0.276 0.001 0.000 -9.404 0.000 -4.834 -11.875
G N1 APARTMENT 1.117 -7.349 0.000 0.000 3.812 2.413 12.213 4.629 0.000 0.212 0.000 0.000 -6.053 0.000 -3.720 -7.274
G N2 APARTMENT 1.112 -7.370 0.000 0.000 3.813 2.413 12.213 4.625 0.000 0.212 0.000 0.000 -6.048 0.000 -3.723 -7.248
G S1 APARTMENT 0.136 -12.935 0.000 0.000 3.721 2.413 12.213 18.643 0.000 0.209 0.001 0.000 -5.996 0.000 -4.216 -14.188
G S2 APARTMENT 0.141 -13.150 0.000 0.000 3.719 2.413 12.213 18.630 0.000 0.210 0.000 0.000 -6.001 0.000 -4.243 -13.932
F2 SW APARTMENT 0.445 -24.580 0.000 0.000 3.622 2.413 12.213 27.139 0.000 0.380 0.002 0.000 -10.697 0.000 -6.960 -3.975
F2 NW APARTMENT 1.983 -14.878 0.000 0.000 3.720 2.413 12.213 13.509 0.000 0.372 0.000 0.000 -10.581 0.000 -6.519 -2.231
F2 SE APARTMENT 0.320 -26.730 0.000 0.000 3.626 2.413 12.213 27.844 0.000 0.378 0.001 0.000 -10.441 0.000 -7.005 -2.618
F2 NE APARTMENT 1.765 -16.058 0.000 0.000 3.739 2.413 12.213 14.040 0.000 0.369 0.000 0.000 -10.035 0.000 -6.496 -1.950
F2 N1 APARTMENT 0.468 -12.266 0.000 0.000 3.739 2.413 12.213 4.350 0.000 0.277 0.363 0.000 -6.529 0.000 -5.028 -0.000
F2 N2 APARTMENT 0.468 -12.300 0.000 0.000 3.741 2.413 12.213 4.347 0.000 0.277 0.395 0.000 -6.524 0.000 -5.030 -0.000
F2 S1 APARTMENT 0.081 -22.100 0.000 0.000 3.602 2.413 12.213 18.189 0.000 0.270 0.002 0.000 -6.505 0.000 -5.583 -2.579
F2 S2 APARTMENT 0.083 -22.231 0.000 0.000 3.601 2.413 12.213 18.185 0.000 0.271 0.002 0.000 -6.507 0.000 -5.590 -2.438
F3 SW APARTMENT 0.395 -26.383 0.000 0.000 3.606 2.413 12.213 26.867 0.000 0.481 0.000 0.000 -10.893 0.000 -7.856 -0.843
F3 NW APARTMENT 1.761 -15.992 0.000 0.000 3.706 2.413 12.213 13.327 0.000 0.470 0.289 0.000 -10.791 0.000 -7.395 -0.000
F3 SE APARTMENT 0.294 -27.638 0.000 0.000 3.616 2.413 12.213 27.610 0.000 0.474 0.001 0.000 -10.590 0.000 -7.868 -0.525
F3 NE APARTMENT 1.588 -17.230 0.000 0.000 3.725 2.413 12.213 13.864 0.000 0.466 0.553 0.000 -10.229 0.000 -7.363 -0.000
F3 N1 APARTMENT 0.372 -13.542 0.000 0.000 3.716 2.413 12.213 4.268 0.000 0.357 2.583 0.000 -6.689 0.000 -5.692 0.000
F3 N2 APARTMENT 0.373 -13.575 0.000 0.000 3.718 2.413 12.213 4.266 0.000 0.357 2.612 0.000 -6.683 0.000 -5.693 0.000
F3 S1 APARTMENT 0.075 -24.394 0.000 0.000 3.580 2.413 12.213 18.014 0.000 0.345 0.649 0.000 -6.642 0.000 -6.250 -0.000
F3 S2 APARTMENT 0.075 -24.451 0.000 0.000 3.580 2.413 12.213 18.011 0.000 0.345 0.709 0.000 -6.641 0.000 -6.254 -0.000
F4 SW APARTMENT 0.406 -26.634 0.000 0.000 3.605 2.413 12.213 26.708 0.000 0.525 0.075 0.000 -10.972 0.000 -8.338 -0.001
F4 NW APARTMENT 1.785 -16.223 0.000 0.000 3.703 2.413 12.213 13.229 0.000 0.513 1.119 0.000 -10.889 0.000 -7.863 -0.000
F4 SE APARTMENT 0.311 -27.766 0.000 0.000 3.617 2.413 12.213 27.462 0.000 0.517 0.234 0.000 -10.658 0.000 -8.342 -0.001
F4 NE APARTMENT 1.623 -17.475 0.000 0.000 3.722 2.413 12.213 13.768 0.000 0.509 1.374 0.000 -10.319 0.000 -7.828 -0.000
F4 N1 APARTMENT 0.376 -13.906 0.000 0.000 3.709 2.413 12.213 4.229 0.000 0.387 3.347 0.000 -6.767 0.000 -6.000 0.000
F4 N2 APARTMENT 0.378 -13.938 0.000 0.000 3.710 2.413 12.213 4.226 0.000 0.387 3.373 0.000 -6.761 0.000 -6.001 0.000
F4 S1 APARTMENT 0.083 -24.916 0.000 0.000 3.576 2.413 12.213 17.912 0.000 0.374 1.597 0.000 -6.698 0.000 -6.554 -0.000
F4 S2 APARTMENT 0.083 -24.953 0.000 0.000 3.576 2.413 12.213 17.910 0.000 0.374 1.637 0.000 -6.696 0.000 -6.557 -0.000
M SW APARTMENT 0.433 -26.886 0.000 0.000 3.605 2.413 12.213 26.580 0.000 0.560 1.008 0.000 -11.038 0.000 -8.888 -0.001
M NW APARTMENT 1.822 -16.534 0.000 0.000 3.702 2.413 12.213 13.152 0.000 0.547 2.034 0.000 -10.965 0.000 -8.383 -0.000
M SE APARTMENT 0.338 -28.008 0.000 0.000 3.617 2.413 12.213 27.340 0.000 0.552 1.146 0.000 -10.719 0.000 -8.891 -0.000
M NE APARTMENT 1.649 -17.793 0.000 0.000 3.721 2.413 12.213 13.692 0.000 0.542 2.298 0.000 -10.389 0.000 -8.346 -0.000
M N1 APARTMENT 0.383 -14.314 0.000 0.000 3.705 2.413 12.213 4.198 0.000 0.411 4.193 0.000 -6.825 0.000 -6.377 0.000
M N2 APARTMENT 0.384 -14.347 0.000 0.000 3.706 2.413 12.213 4.196 0.000 0.411 4.221 0.000 -6.819 0.000 -6.378 0.000
M S1 APARTMENT 0.095 -25.356 0.000 0.000 3.574 2.413 12.213 17.832 0.000 0.397 2.528 0.000 -6.742 0.000 -6.953 -0.000
M S2 APARTMENT 0.095 -25.390 0.000 0.000 3.575 2.413 12.213 17.830 0.000 0.398 2.562 0.000 -6.740 0.000 -6.956 -0.000
F6 SW APARTMENT 0.514 -25.688 0.000 0.000 3.614 2.413 12.213 26.515 0.000 0.589 0.180 0.000 -11.026 0.000 -9.325 -0.001
F6 NW APARTMENT 2.136 -15.781 0.000 0.000 3.712 2.413 12.213 13.133 0.000 0.576 1.311 0.000 -10.948 0.000 -8.765 -0.000
F6 SE APARTMENT 0.411 -26.797 0.000 0.000 3.626 2.413 12.213 27.279 0.000 0.581 0.310 0.000 -10.706 0.000 -9.329 -0.001
F6 NE APARTMENT 1.944 -16.987 0.000 0.000 3.730 2.413 12.213 13.674 0.000 0.570 1.546 0.000 -10.373 0.000 -8.730 -0.000
F6 N1 APARTMENT 0.483 -13.571 0.000 0.000 3.716 2.413 12.213 4.200 0.000 0.430 3.556 0.000 -6.813 0.000 -6.627 0.000
F6 N2 APARTMENT 0.483 -13.605 0.000 0.000 3.718 2.413 12.213 4.197 0.000 0.430 3.585 0.000 -6.807 0.000 -6.627 0.000
F6 S1 APARTMENT 0.112 -24.232 0.000 0.000 3.582 2.413 12.213 17.790 0.000 0.417 1.702 0.000 -6.738 0.000 -7.259 -0.000
F6 S2 APARTMENT 0.111 -24.264 0.000 0.000 3.583 2.413 12.213 17.788 0.000 0.417 1.736 0.000 -6.736 0.000 -7.262 -0.000
F7 SW APARTMENT 0.591 -24.962 0.000 0.000 3.622 2.413 12.213 26.452 0.000 0.614 0.000 0.000 -11.027 0.000 -9.708 -0.207
F7 NW APARTMENT 2.394 -15.389 0.000 0.000 3.720 2.413 12.213 13.109 0.000 0.600 0.991 0.000 -10.946 0.000 -9.104 -0.000
F7 SE APARTMENT 0.480 -26.068 0.000 0.000 3.633 2.413 12.213 27.218 0.000 0.606 0.000 0.000 -10.706 0.000 -9.712 -0.077
F7 NE APARTMENT 2.186 -16.571 0.000 0.000 3.737 2.413 12.213 13.650 0.000 0.594 1.217 0.000 -10.370 0.000 -9.070 -0.000
F7 N1 APARTMENT 0.574 -13.187 0.000 0.000 3.725 2.413 12.213 4.197 0.000 0.447 3.275 0.000 -6.808 0.000 -6.849 0.000
F7 N2 APARTMENT 0.574 -13.220 0.000 0.000 3.726 2.413 12.213 4.194 0.000 0.447 3.305 0.000 -6.802 0.000 -6.850 0.000
F7 S1 APARTMENT 0.128 -23.570 0.000 0.000 3.589 2.413 12.213 17.750 0.000 0.434 1.309 0.000 -6.740 0.000 -7.526 -0.000
F7 S2 APARTMENT 0.129 -23.603 0.000 0.000 3.589 2.413 12.213 17.748 0.000 0.434 1.344 0.000 -6.738 0.000 -7.529 -0.000
F8 SW APARTMENT 0.678 -24.369 0.000 0.000 3.629 2.413 12.213 26.398 0.000 0.644 0.000 0.000 -11.025 0.000 -10.066 -0.514
F8 NW APARTMENT 2.668 -15.159 0.000 0.000 3.726 2.413 12.213 13.086 0.000 0.628 0.798 0.000 -10.947 0.000 -9.426 -0.001
F8 SE APARTMENT 0.564 -25.480 0.000 0.000 3.640 2.413 12.213 27.166 0.000 0.635 0.001 0.000 -10.704 0.000 -10.071 -0.376
F8 NE APARTMENT 2.433 -16.316 0.000 0.000 3.743 2.413 12.213 13.628 0.000 0.621 1.027 0.000 -10.370 0.000 -9.391 -0.000
F8 N1 APARTMENT 0.682 -12.949 0.000 0.000 3.732 2.413 12.213 4.193 0.000 0.468 3.118 0.000 -6.805 0.000 -7.065 0.000
F8 N2 APARTMENT 0.684 -12.986 0.000 0.000 3.734 2.413 12.213 4.190 0.000 0.467 3.151 0.000 -6.799 0.000 -7.066 0.000
F8 S1 APARTMENT 0.150 -23.014 0.000 0.000 3.596 2.413 12.213 17.717 0.000 0.455 0.988 0.000 -6.739 0.000 -7.779 -0.000
F8 S2 APARTMENT 0.151 -23.048 0.000 0.000 3.597 2.413 12.213 17.714 0.000 0.456 1.024 0.000 -6.737 0.000 -7.782 -0.000
F9 SW APARTMENT 0.909 -23.721 0.000 0.000 3.642 2.413 12.213 26.376 0.000 0.672 0.003 0.000 -10.988 0.000 -10.361 -1.154
F9 NW APARTMENT 3.285 -15.249 0.000 0.000 3.733 2.413 12.213 13.076 0.000 0.653 0.517 0.000 -10.937 0.000 -9.704 -0.000
F9 SE APARTMENT 0.777 -24.833 0.000 0.000 3.653 2.413 12.213 27.143 0.000 0.664 0.001 0.000 -10.670 0.000 -10.369 -0.991
F9 NE APARTMENT 2.959 -16.327 0.000 0.000 3.749 2.413 12.213 13.619 0.000 0.645 0.760 0.000 -10.362 0.000 -9.669 -0.000
F9 N1 APARTMENT 0.965 -12.882 0.000 0.000 3.740 2.413 12.213 4.194 0.000 0.488 2.912 0.000 -6.792 0.000 -7.251 -0.000
F9 N2 APARTMENT 0.968 -12.917 0.000 0.000 3.741 2.413 12.213 4.190 0.000 0.488 2.944 0.000 -6.787 0.000 -7.254 -0.000
F9 S1 APARTMENT 0.205 -22.324 0.000 0.000 3.612 2.413 12.213 17.705 0.000 0.478 0.389 0.000 -6.712 0.000 -7.979 -0.000
F9 S2 APARTMENT 0.205 -22.369 0.000 0.000 3.612 2.413 12.213 17.702 0.000 0.479 0.437 0.000 -6.710 0.000 -7.983 -0.000
T SW APARTMENT 4.351 -24.474 0.000 0.000 3.706 2.413 12.213 26.051 0.000 0.693 0.000 0.000 -10.372 0.000 -10.481 -4.099
T NW APARTMENT 7.501 -16.418 0.000 0.000 3.754 2.413 12.213 12.764 0.000 0.669 0.000 0.000 -10.494 0.000 -9.988 -2.414
T SE APARTMENT 3.990 -24.974 0.000 0.000 3.715 2.413 12.213 26.840 0.000 0.690 0.001 0.000 -10.092 0.000 -10.500 -4.293
T NE APARTMENT 6.733 -16.832 0.000 0.000 3.771 2.413 12.213 13.375 0.000 0.668 0.000 0.000 -9.990 0.000 -9.944 -2.406
T N1 APARTMENT 3.445 -12.998 0.000 0.000 3.763 2.413 12.213 4.084 0.000 0.503 0.550 0.000 -6.525 0.000 -7.448 -0.000
T N2 APARTMENT 3.465 -13.035 0.000 0.000 3.764 2.413 12.213 4.078 0.000 0.503 0.572 0.000 -6.519 0.000 -7.455 -0.000
T S1 APARTMENT 1.375 -21.725 0.000 0.000 3.688 2.413 12.213 17.546 0.000 0.514 0.001 0.000 -6.368 0.000 -8.047 -1.610
T S2 APARTMENT 1.382 -21.771 0.000 0.000 3.688 2.413 12.213 17.541 0.000 0.514 0.002 0.000 -6.364 0.000 -8.053 -1.564
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 6.542 0.000 1.857 7.411 0.000 -2.333 0.000 -32.007 -0.003
F2 CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 2.983 0.000 0.021 0.000 0.000 -1.358 0.000 -0.628 -19.546
F3 CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 2.931 0.000 0.023 0.000 0.000 -1.406 0.000 -0.767 -19.311
F4 CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 2.902 0.000 0.025 0.000 0.000 -1.429 0.000 -0.869 -19.159
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 37.059 0.000 2.867 0.000 0.022 0.000 0.000 -1.464 0.000 -0.991 -37.494
F6 CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 2.880 0.000 0.029 0.000 0.000 -1.438 0.000 -1.008 -18.993
F7 CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 2.880 0.000 0.031 0.000 0.000 -1.430 0.000 -1.055 -18.956
F8 CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 2.876 0.000 0.032 0.000 0.000 -1.428 0.000 -1.101 -18.909
F9 CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 2.875 0.000 0.032 0.000 0.000 -1.426 0.000 -1.141 -18.869
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 7.937 2.808 0.000 0.017 0.000 0.000 -1.377 0.000 -1.214 -26.699
Total Facility 94.704 -1517.590 0.000 0.000 291.295 416.414 980.287 1287.450 0.000 39.107 92.883 0.000 -702.118 0.000 -636.464 -345.962


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 28-SEP-16:30 0.00 -2488.03 0.00 0.00 81.74 144.04 588.62 3337.83 0.00 33.37 0.00 0.00 0.00 0.00 0.00 -1697.58
G NW APARTMENT 25-JUN-17:20 0.00 -2345.92 0.00 0.00 139.30 194.45 588.62 3265.26 0.00 93.41 0.00 0.00 0.00 0.00 0.00 -1935.13
OFFICE 12-SEP-12:30 0.00 -3084.83 0.00 0.00 65.17 1622.33 544.91 3069.56 0.00 31.19 0.00 0.00 0.00 0.00 0.00 -2248.34
G NE APARTMENT 28-JUN-08:15 0.00 -1726.35 0.00 0.00 40.58 28.81 394.37 2858.43 0.00 180.33 0.00 0.00 0.00 0.00 0.00 -1776.16
G N1 APARTMENT 11-JUN-18:30 0.00 -1226.35 0.00 0.00 141.82 230.46 547.42 969.60 0.00 166.50 0.00 0.00 0.00 0.00 0.00 -829.44
G N2 APARTMENT 11-JUN-18:30 0.00 -1205.39 0.00 0.00 141.82 230.46 547.42 970.08 0.00 166.50 0.00 0.00 0.00 0.00 0.00 -850.88
G S1 APARTMENT 29-SEP-11:30 0.00 -1425.86 0.00 0.00 39.53 28.81 406.15 3271.56 0.00 60.99 0.00 0.00 0.00 0.00 0.00 -2381.18
G S2 APARTMENT 29-SEP-11:30 0.00 -1482.87 0.00 0.00 39.59 28.81 406.15 3270.96 0.00 63.22 0.00 0.00 0.00 0.00 0.00 -2325.85
F2 SW APARTMENT 11-OCT-15:08 0.00 -3223.15 0.00 0.00 48.90 100.83 470.89 3366.29 0.00 727.89 0.00 0.00 0.00 0.00 0.00 -1491.66
F2 NW APARTMENT 25-JUN-17:20 0.00 -3003.09 0.00 0.00 139.62 194.45 588.62 3229.62 0.00 134.54 0.00 0.00 0.00 0.00 0.00 -1283.77
F2 SE APARTMENT 01-OCT-11:15 0.00 -2867.70 0.00 0.00 40.64 28.81 406.15 3919.83 0.00 0.00 0.00 0.00 0.00 0.00 -6.86 -1520.86
F2 NE APARTMENT 28-JUN-08:15 0.00 -2303.47 0.00 0.00 40.49 28.81 394.37 2829.86 0.00 198.49 0.00 0.00 0.00 0.00 0.00 -1188.55
F2 N1 APARTMENT 11-JUN-18:30 0.00 -1655.17 0.00 0.00 141.81 230.46 547.42 951.22 0.00 189.63 0.00 0.00 0.00 0.00 0.00 -405.38
F2 N2 APARTMENT 11-JUN-18:30 0.00 -1638.19 0.00 0.00 141.81 230.46 547.42 951.52 0.00 189.63 0.00 0.00 0.00 0.00 0.00 -422.65
F2 S1 APARTMENT 01-NOV-12:30 0.00 -2099.95 0.00 0.00 40.20 28.81 388.49 3593.23 0.00 0.00 0.00 0.00 0.00 0.00 -192.22 -1758.55
F2 S2 APARTMENT 01-NOV-12:30 0.00 -2117.61 0.00 0.00 40.21 28.81 388.49 3593.01 0.00 0.00 0.00 0.00 0.00 0.00 -192.16 -1740.75
F3 SW APARTMENT 10-OCT-16:00 0.00 -3259.67 0.00 0.00 48.80 100.83 470.89 3282.69 0.00 600.33 0.00 0.00 0.00 0.00 0.00 -1243.88
F3 NW APARTMENT 22-JUL-17:30 0.00 -3019.42 0.00 0.00 141.81 194.45 588.62 3026.50 0.00 184.62 0.00 0.00 0.00 0.00 0.00 -1116.57
F3 SE APARTMENT 01-OCT-10:45 0.00 -2728.91 0.00 0.00 40.69 28.81 412.03 4054.07 0.00 0.00 0.00 0.00 0.00 0.00 -92.76 -1713.93
F3 NE APARTMENT 28-JUN-08:15 0.00 -2346.50 0.00 0.00 40.46 28.81 394.37 2818.12 0.00 210.50 0.00 0.00 0.00 0.00 0.00 -1145.76
F3 N1 APARTMENT 07-JUN-18:00 0.00 -1725.93 0.00 0.00 141.81 194.45 588.62 204.72 0.00 471.70 124.64 0.00 0.00 0.00 0.00 0.00
F3 N2 APARTMENT 07-JUN-18:00 0.00 -1712.68 0.00 0.00 141.81 194.45 588.62 204.54 0.00 468.53 114.73 0.00 0.00 0.00 0.00 0.00
F3 S1 APARTMENT 29-DEC-12:45 0.00 -2169.49 0.00 0.00 40.75 28.81 406.15 3969.95 0.00 0.00 0.00 0.00 0.00 0.00 -61.84 -2214.32
F3 S2 APARTMENT 29-DEC-12:45 0.00 -2176.74 0.00 0.00 40.75 28.81 406.15 3969.81 0.00 0.00 0.00 0.00 0.00 0.00 -61.84 -2206.93
F4 SW APARTMENT 10-OCT-16:00 0.00 -3284.93 0.00 0.00 48.80 100.83 470.89 3264.25 0.00 647.43 0.00 0.00 0.00 0.00 0.00 -1247.27
F4 NW APARTMENT 22-JUL-17:30 0.00 -3036.35 0.00 0.00 141.81 194.45 588.62 3012.46 0.00 205.63 0.00 0.00 0.00 0.00 0.00 -1106.62
F4 SE APARTMENT 01-OCT-10:45 0.00 -2729.32 0.00 0.00 40.69 28.81 412.03 4044.22 0.00 0.00 0.00 0.00 0.00 0.00 -98.67 -1697.76
F4 NE APARTMENT 28-JUN-08:15 0.00 -2371.75 0.00 0.00 40.49 28.81 394.37 2810.43 0.00 222.21 0.00 0.00 0.00 0.00 0.00 -1124.56
F4 N1 APARTMENT 23-JUN-21:00 0.00 -1752.74 0.00 0.00 162.98 158.44 500.33 3.62 0.00 606.02 321.35 0.00 0.00 0.00 0.00 0.00
F4 N2 APARTMENT 23-JUN-21:00 0.00 -1738.37 0.00 0.00 162.98 158.44 500.33 3.75 0.00 603.27 309.60 0.00 0.00 0.00 0.00 0.00
F4 S1 APARTMENT 29-DEC-12:45 0.00 -2186.92 0.00 0.00 40.73 28.81 406.15 3957.34 0.00 0.00 0.00 0.00 0.00 0.00 -69.35 -2176.75
F4 S2 APARTMENT 29-DEC-12:45 0.00 -2192.35 0.00 0.00 40.73 28.81 406.15 3957.23 0.00 0.00 0.00 0.00 0.00 0.00 -69.36 -2171.21
M SW APARTMENT 10-OCT-16:00 0.00 -3330.29 0.00 0.00 48.84 100.83 470.89 3250.08 0.00 687.11 0.00 0.00 0.00 0.00 0.00 -1227.47
M NW APARTMENT 22-JUL-17:30 0.00 -3068.06 0.00 0.00 141.68 194.45 588.62 3000.66 0.00 222.55 0.00 0.00 0.00 0.00 0.00 -1079.91
M SE APARTMENT 01-OCT-11:00 0.00 -2761.16 0.00 0.00 40.47 28.81 412.03 3967.46 0.00 0.00 0.00 0.00 0.00 0.00 -48.13 -1639.49
M NE APARTMENT 28-JUN-08:15 0.00 -2412.05 0.00 0.00 40.50 28.81 394.37 2803.49 0.00 231.19 0.00 0.00 0.00 0.00 0.00 -1086.31
M N1 APARTMENT 23-JUN-21:00 0.00 -1799.55 0.00 0.00 162.98 158.44 500.33 3.96 0.00 638.84 335.01 0.00 0.00 0.00 0.00 0.00
M N2 APARTMENT 23-JUN-21:00 0.00 -1785.22 0.00 0.00 162.98 158.44 500.33 4.08 0.00 635.79 323.60 0.00 0.00 0.00 0.00 0.00
M S1 APARTMENT 29-DEC-12:45 0.00 -2220.17 0.00 0.00 40.74 28.81 406.15 3946.95 0.00 0.00 0.00 0.00 0.00 0.00 -75.43 -2127.03
M S2 APARTMENT 29-DEC-12:45 0.00 -2225.16 0.00 0.00 40.74 28.81 406.15 3946.84 0.00 0.00 0.00 0.00 0.00 0.00 -75.44 -2121.93
F6 SW APARTMENT 10-OCT-16:00 0.00 -3298.03 0.00 0.00 48.87 100.83 470.89 3240.59 0.00 717.16 0.00 0.00 0.00 0.00 0.00 -1280.31
F6 NW APARTMENT 22-JUL-17:30 0.00 -3024.47 0.00 0.00 141.48 194.45 588.62 2992.56 0.00 236.70 0.00 0.00 0.00 0.00 0.00 -1129.34
F6 SE APARTMENT 01-OCT-11:00 0.00 -2726.59 0.00 0.00 40.51 28.81 412.03 3962.60 0.00 0.00 0.00 0.00 0.00 0.00 -50.51 -1666.85
F6 NE APARTMENT 28-JUN-08:15 0.00 -2379.53 0.00 0.00 40.51 28.81 394.37 2799.26 0.00 237.96 0.00 0.00 0.00 0.00 0.00 -1121.38
F6 N1 APARTMENT 23-JUN-21:00 0.00 -1772.80 0.00 0.00 162.97 158.44 500.33 5.45 0.00 661.53 284.08 0.00 0.00 0.00 0.00 0.00
F6 N2 APARTMENT 23-JUN-21:00 0.00 -1758.55 0.00 0.00 162.97 158.44 500.33 5.56 0.00 658.18 273.08 0.00 0.00 0.00 0.00 0.00
F6 S1 APARTMENT 29-DEC-13:00 0.00 -2180.55 0.00 0.00 40.61 28.81 406.15 3923.42 0.00 0.00 0.00 0.00 0.00 0.00 -58.96 -2159.49
F6 S2 APARTMENT 29-DEC-12:45 0.00 -2185.27 0.00 0.00 40.75 28.81 406.15 3939.39 0.00 0.00 0.00 0.00 0.00 0.00 -80.61 -2149.22
F7 SW APARTMENT 10-OCT-16:00 0.00 -3286.10 0.00 0.00 48.90 100.83 470.89 3232.15 0.00 742.47 0.00 0.00 0.00 0.00 0.00 -1309.13
F7 NW APARTMENT 22-JUL-17:30 0.00 -3009.50 0.00 0.00 141.33 194.45 588.62 2985.28 0.00 249.09 0.00 0.00 0.00 0.00 0.00 -1149.28
F7 SE APARTMENT 01-OCT-11:00 0.00 -2714.81 0.00 0.00 40.54 28.81 412.03 3957.60 0.00 0.00 0.00 0.00 0.00 0.00 -52.84 -1671.32
F7 NE APARTMENT 28-JUN-08:15 0.00 -2373.29 0.00 0.00 40.52 28.81 394.37 2794.96 0.00 243.98 0.00 0.00 0.00 0.00 0.00 -1129.35
F7 N1 APARTMENT 23-JUN-21:00 0.00 -1770.51 0.00 0.00 162.97 158.44 500.33 6.15 0.00 680.91 261.70 0.00 0.00 0.00 0.00 0.00
F7 N2 APARTMENT 23-JUN-21:00 0.00 -1756.34 0.00 0.00 162.97 158.44 500.33 6.25 0.00 677.29 251.06 0.00 0.00 0.00 0.00 0.00
F7 S1 APARTMENT 29-DEC-13:00 0.00 -2165.61 0.00 0.00 40.68 28.81 406.15 3919.02 0.00 0.00 0.00 0.00 0.00 0.00 -62.24 -2166.80
F7 S2 APARTMENT 29-DEC-13:00 0.00 -2170.16 0.00 0.00 40.67 28.81 406.15 3918.93 0.00 0.00 0.00 0.00 0.00 0.00 -62.25 -2162.16
F8 SW APARTMENT 10-OCT-16:00 0.00 -3288.25 0.00 0.00 48.90 100.83 470.89 3224.59 0.00 766.63 0.00 0.00 0.00 0.00 0.00 -1323.59
F8 NW APARTMENT 18-JUL-17:20 0.00 -3013.65 0.00 0.00 138.55 194.45 588.62 3226.43 0.00 264.99 0.00 0.00 0.00 0.00 0.00 -1399.39
F8 SE APARTMENT 01-OCT-11:00 0.00 -2716.47 0.00 0.00 40.57 28.81 412.03 3952.79 0.00 0.00 0.00 0.00 0.00 0.00 -54.75 -1662.98
F8 NE APARTMENT 28-JUN-08:15 0.00 -2377.57 0.00 0.00 40.51 28.81 394.37 2790.52 0.00 248.41 0.00 0.00 0.00 0.00 0.00 -1125.05
F8 N1 APARTMENT 23-JUN-21:00 0.00 -1782.52 0.00 0.00 162.97 158.44 500.33 6.37 0.00 698.26 256.16 0.00 0.00 0.00 0.00 0.00
F8 N2 APARTMENT 23-JUN-21:00 0.00 -1768.44 0.00 0.00 162.97 158.44 500.33 6.46 0.00 694.40 245.85 0.00 0.00 0.00 0.00 0.00
F8 S1 APARTMENT 29-DEC-13:00 0.00 -2161.05 0.00 0.00 40.75 28.81 406.15 3915.48 0.00 0.00 0.00 0.00 0.00 0.00 -65.08 -2165.06
F8 S2 APARTMENT 29-DEC-13:00 0.00 -2165.50 0.00 0.00 40.75 28.81 406.15 3915.39 0.00 0.00 0.00 0.00 0.00 0.00 -65.09 -2160.52
F9 SW APARTMENT 10-OCT-15:45 0.00 -3393.77 0.00 0.00 48.90 100.83 470.89 3489.85 0.00 805.91 0.00 0.00 0.00 0.00 0.00 -1522.61
F9 NW APARTMENT 18-JUL-17:20 0.00 -3126.35 0.00 0.00 138.76 194.45 588.62 3217.10 0.00 276.24 0.00 0.00 0.00 0.00 0.00 -1288.81
F9 SE APARTMENT 10-OCT-15:45 0.00 -2793.28 0.00 0.00 48.90 100.83 470.89 1466.77 0.00 818.06 0.00 0.00 0.00 0.00 0.00 -112.17
F9 NE APARTMENT 28-JUN-08:15 0.00 -2416.81 0.00 0.00 40.54 28.81 394.37 2786.02 0.00 254.40 0.00 0.00 0.00 0.00 0.00 -1087.34
F9 N1 APARTMENT 23-JUN-21:00 0.00 -1885.38 0.00 0.00 162.97 158.44 500.33 4.21 0.00 720.34 339.09 0.00 0.00 0.00 0.00 0.00
F9 N2 APARTMENT 23-JUN-21:00 0.00 -1871.02 0.00 0.00 162.97 158.44 500.33 4.34 0.00 716.79 328.15 0.00 0.00 0.00 0.00 0.00
F9 S1 APARTMENT 07-NOV-11:45 0.00 -2179.44 0.00 0.00 40.75 28.81 412.03 3912.73 0.00 0.00 0.00 0.00 0.00 0.00 -63.07 -2151.82
F9 S2 APARTMENT 07-NOV-11:45 0.00 -2188.17 0.00 0.00 40.75 28.81 412.03 3912.54 0.00 0.00 0.00 0.00 0.00 0.00 -63.08 -2142.88
T SW APARTMENT 10-OCT-15:45 0.00 -4143.12 0.00 0.00 48.90 100.83 470.89 3446.67 0.00 958.83 0.00 0.00 0.00 0.00 0.00 -883.00
T NW APARTMENT 18-JUL-17:20 0.00 -3852.45 0.00 0.00 138.91 194.45 588.62 3166.24 0.00 286.70 0.00 0.00 0.00 0.00 0.00 -522.48
T SE APARTMENT 01-OCT-12:00 0.00 -3588.82 0.00 0.00 39.87 28.81 406.15 3622.47 0.00 44.79 0.00 0.00 0.00 0.00 0.00 -553.27
T NE APARTMENT 28-JUN-08:15 0.00 -3012.37 0.00 0.00 40.75 28.81 394.37 2753.66 0.00 284.76 0.00 0.00 0.00 0.00 0.00 -489.98
T N1 APARTMENT 23-JUN-20:53 0.00 -2389.01 0.00 0.00 162.99 158.44 500.33 4.34 0.00 943.84 619.08 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 23-JUN-20:53 0.00 -2385.19 0.00 0.00 162.99 158.44 500.33 4.76 0.00 945.87 612.81 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 07-NOV-12:45 0.00 -2930.81 0.00 0.00 40.75 28.81 406.15 3641.74 0.00 0.00 0.00 0.00 0.00 0.00 -67.50 -1119.14
T S2 APARTMENT 07-NOV-12:45 0.00 -2942.68 0.00 0.00 40.75 28.81 406.15 3641.49 0.00 0.00 0.00 0.00 0.00 0.00 -67.50 -1107.02
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 22-JUL-17:30 0.00 -174963.77 0.00 0.00 11106.11 22204.40 47141.46 102332.50 0.00 14789.82 0.00 0.00 0.00 0.00 0.00 -22610.52


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 18-JAN-01:30 1023.99 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 0.00 0.00 -979.11 0.00 -424.83 -65.46
G NW APARTMENT 17-JAN-08:05 1128.54 0.00 0.00 0.00 73.97 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -808.40 0.00 -433.66 -392.15
OFFICE 17-JAN-07:50 1090.71 0.00 0.00 0.00 0.00 379.58 194.98 0.00 0.00 0.00 0.00 0.00 -783.55 0.00 -446.29 -435.43
G NE APARTMENT 14-DEC-04:00 1170.18 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 44.33 0.00 -988.95 0.00 -653.30 0.00
G N1 APARTMENT 24-JAN-14:55 1055.52 0.00 0.00 0.00 46.29 28.81 382.60 211.61 0.00 0.00 0.00 0.00 0.00 0.00 -962.01 -762.82
G N2 APARTMENT 24-JAN-14:55 1057.77 0.00 0.00 0.00 46.29 28.81 382.60 211.60 0.00 0.00 0.00 0.00 0.00 0.00 -961.94 -765.13
G S1 APARTMENT 05-FEB-06:55 730.62 0.00 0.00 0.00 189.67 100.83 317.85 0.00 0.00 0.00 0.00 0.00 -696.17 0.00 -155.94 -486.86
G S2 APARTMENT 05-FEB-06:55 718.74 0.00 0.00 0.00 189.67 100.83 317.85 0.00 0.00 0.00 0.00 0.00 -696.18 0.00 -155.94 -474.98
F2 SW APARTMENT 18-JAN-02:00 1012.34 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 152.18 0.00 -1015.78 0.00 -594.15 0.00
F2 NW APARTMENT 14-DEC-04:00 1226.20 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 325.84 0.00 -1040.12 0.00 -939.67 0.00
F2 SE APARTMENT 18-JAN-02:00 982.46 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 191.81 0.00 -1025.53 0.00 -594.15 0.00
F2 NE APARTMENT 14-DEC-04:00 1323.81 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 211.98 0.00 -1023.88 0.00 -939.67 0.00
F2 N1 APARTMENT 24-JAN-15:00 902.54 0.00 0.00 0.00 44.95 28.81 382.60 183.34 0.00 0.00 0.00 0.00 0.00 0.00 -1181.84 -360.40
F2 N2 APARTMENT 24-JAN-15:00 901.84 0.00 0.00 0.00 44.95 28.81 382.60 183.31 0.00 0.00 0.00 0.00 0.00 0.00 -1181.81 -359.70
F2 S1 APARTMENT 18-JAN-23:15 560.14 0.00 0.00 0.00 189.67 36.01 341.40 0.00 0.00 0.00 0.00 0.00 -673.41 0.00 -128.93 -324.87
F2 S2 APARTMENT 18-JAN-23:15 555.12 0.00 0.00 0.00 189.67 36.01 341.40 0.00 0.00 0.00 0.00 0.00 -673.47 0.00 -128.93 -319.79
F3 SW APARTMENT 18-JAN-01:30 1034.92 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 281.82 0.00 -1038.28 0.00 -723.88 0.00
F3 NW APARTMENT 14-DEC-04:00 1324.34 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 417.60 0.00 -1056.44 0.00 -1113.25 0.00
F3 SE APARTMENT 18-JAN-01:30 1048.63 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 277.62 0.00 -1047.78 0.00 -723.88 0.00
F3 NE APARTMENT 14-DEC-04:00 1423.96 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 299.79 0.00 -1038.24 0.00 -1113.25 0.00
F3 N1 APARTMENT 24-JAN-15:00 1035.29 0.00 0.00 0.00 44.44 28.81 382.60 172.08 0.00 0.00 0.00 0.00 0.00 0.00 -1331.35 -331.86
F3 N2 APARTMENT 24-JAN-15:00 1033.20 0.00 0.00 0.00 44.44 28.81 382.60 172.13 0.00 0.00 0.00 0.00 0.00 0.00 -1331.31 -329.88
F3 S1 APARTMENT 19-JAN-05:45 457.24 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -570.48 0.00 -51.29 -371.87
F3 S2 APARTMENT 17-JAN-08:45 392.42 0.00 0.00 0.00 73.97 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -401.79 0.00 -419.83 -76.47
F4 SW APARTMENT 18-JAN-01:30 1100.28 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 312.21 0.00 -1048.29 0.00 -809.61 0.00
F4 NW APARTMENT 14-DEC-04:00 1437.00 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 445.76 0.00 -1065.36 0.00 -1245.16 0.00
F4 SE APARTMENT 18-JAN-01:30 1120.33 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 302.35 0.00 -1058.47 0.00 -809.61 0.00
F4 NE APARTMENT 14-DEC-04:00 1532.48 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 331.30 0.00 -1046.37 0.00 -1245.16 0.00
F4 N1 APARTMENT 24-JAN-15:00 1119.33 0.00 0.00 0.00 44.24 28.81 382.60 166.29 0.00 0.00 0.00 0.00 0.00 0.00 -1450.58 -290.69
F4 N2 APARTMENT 24-JAN-15:00 1115.88 0.00 0.00 0.00 44.25 28.81 382.60 166.39 0.00 0.00 0.00 0.00 0.00 0.00 -1450.53 -287.40
F4 S1 APARTMENT 18-JAN-01:30 410.41 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 283.66 0.00 -651.14 0.00 -488.34 0.00
F4 S2 APARTMENT 18-JAN-01:30 411.79 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 282.22 0.00 -651.08 0.00 -488.34 0.00
M SW APARTMENT 18-JAN-01:30 1156.25 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 334.88 0.00 -1056.13 0.00 -880.41 0.00
M NW APARTMENT 14-DEC-04:00 1524.64 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 473.98 0.00 -1072.27 0.00 -1354.10 0.00
M SE APARTMENT 18-JAN-01:30 1176.22 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 325.85 0.00 -1067.07 0.00 -880.41 0.00
M NE APARTMENT 14-DEC-04:00 1615.68 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 363.61 0.00 -1052.94 0.00 -1354.10 0.00
M N1 APARTMENT 09-NOV-10:15 1376.53 0.00 0.00 0.00 40.75 28.81 406.15 96.05 0.00 0.00 23.83 0.00 0.00 0.00 -1972.11 0.00
M N2 APARTMENT 09-NOV-10:15 1388.69 0.00 0.00 0.00 40.75 28.81 406.15 96.04 0.00 0.00 11.35 0.00 0.00 0.00 -1971.78 0.00
M S1 APARTMENT 18-JAN-01:30 435.61 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 306.43 0.00 -656.41 0.00 -531.04 0.00
M S2 APARTMENT 18-JAN-01:30 437.10 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 304.87 0.00 -656.34 0.00 -531.04 0.00
F6 SW APARTMENT 18-JAN-01:30 1253.54 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 301.92 0.00 -1059.33 0.00 -941.54 0.00
F6 NW APARTMENT 09-NOV-10:15 1790.61 0.00 0.00 0.00 41.24 28.81 406.15 167.68 0.00 0.00 0.00 0.00 0.00 0.00 -2197.71 -236.77
F6 SE APARTMENT 18-JAN-01:30 1274.65 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 292.30 0.00 -1070.82 0.00 -941.54 0.00
F6 NE APARTMENT 14-DEC-04:00 1748.10 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 327.48 0.00 -1055.16 0.00 -1448.17 0.00
F6 N1 APARTMENT 09-NOV-10:15 2003.91 0.00 0.00 0.00 40.84 28.81 406.15 95.59 0.00 0.00 0.00 0.00 0.00 0.00 -2081.58 -493.71
F6 N2 APARTMENT 09-NOV-10:15 1955.52 0.00 0.00 0.00 40.85 28.81 406.15 95.63 0.00 0.00 0.00 0.00 0.00 0.00 -2082.07 -444.89
F6 S1 APARTMENT 18-JAN-01:30 509.54 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 271.50 0.00 -658.54 0.00 -567.91 0.00
F6 S2 APARTMENT 18-JAN-01:30 510.90 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 270.08 0.00 -658.48 0.00 -567.91 0.00
F7 SW APARTMENT 18-JAN-01:30 1335.18 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 277.68 0.00 -1062.47 0.00 -995.79 0.00
F7 NW APARTMENT 09-NOV-10:15 1902.06 0.00 0.00 0.00 41.60 28.81 406.15 169.23 0.00 0.00 0.00 0.00 0.00 0.00 -2306.71 -241.13
F7 SE APARTMENT 18-JAN-01:30 1356.97 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 267.83 0.00 -1074.41 0.00 -995.79 0.00
F7 NE APARTMENT 14-DEC-04:00 1853.37 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 308.12 0.00 -1057.56 0.00 -1531.68 0.00
F7 N1 APARTMENT 09-NOV-10:15 2066.98 0.00 0.00 0.00 41.15 28.81 406.15 96.31 0.00 0.00 0.00 0.00 0.00 0.00 -2189.71 -449.69
F7 N2 APARTMENT 09-NOV-10:15 2060.21 0.00 0.00 0.00 41.17 28.81 406.15 96.42 0.00 0.00 0.00 0.00 0.00 0.00 -2189.61 -443.15
F7 S1 APARTMENT 18-JAN-01:30 564.78 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 251.03 0.00 -660.58 0.00 -600.63 0.00
F7 S2 APARTMENT 18-JAN-01:30 565.87 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 249.88 0.00 -660.52 0.00 -600.63 0.00
F8 SW APARTMENT 18-JAN-01:15 1422.33 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 258.14 0.00 -1066.56 0.00 -1059.32 0.00
F8 NW APARTMENT 09-NOV-10:15 1889.78 0.00 0.00 0.00 41.94 28.81 406.15 171.36 0.00 0.00 0.00 0.00 0.00 0.00 -2411.93 -126.10
F8 SE APARTMENT 18-JAN-01:15 1444.58 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 248.22 0.00 -1078.89 0.00 -1059.31 0.00
F8 NE APARTMENT 14-DEC-04:00 1951.85 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 287.14 0.00 -1059.49 0.00 -1607.25 0.00
F8 N1 APARTMENT 09-NOV-10:15 1994.71 0.00 0.00 0.00 41.47 28.81 406.15 97.55 0.00 0.00 0.00 0.00 0.00 0.00 -2289.93 -278.76
F8 N2 APARTMENT 09-NOV-10:15 1985.84 0.00 0.00 0.00 41.49 28.81 406.15 97.73 0.00 0.00 0.00 0.00 0.00 0.00 -2289.83 -270.17
F8 S1 APARTMENT 18-JAN-01:30 618.45 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 228.30 0.00 -661.92 0.00 -630.24 0.00
F8 S2 APARTMENT 18-JAN-01:30 619.57 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 227.13 0.00 -661.87 0.00 -630.24 0.00
F9 SW APARTMENT 18-JAN-01:30 1589.50 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 117.67 0.00 -1062.66 0.00 -1089.92 0.00
F9 NW APARTMENT 14-DEC-04:00 2005.36 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 320.46 0.00 -1076.97 0.00 -1676.59 0.00
F9 SE APARTMENT 18-JAN-01:30 1611.15 0.00 0.00 0.00 189.67 14.40 241.33 0.00 0.00 0.00 108.70 0.00 -1075.33 0.00 -1089.92 0.00
F9 NE APARTMENT 14-DEC-04:00 2098.29 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 209.03 0.00 -1058.48 0.00 -1676.59 0.00
F9 N1 APARTMENT 09-NOV-10:15 2023.33 0.00 0.00 0.00 41.89 28.81 406.15 100.88 0.00 0.00 0.00 0.00 0.00 0.00 -2383.49 -217.56
F9 N2 APARTMENT 09-NOV-10:15 2026.59 0.00 0.00 0.00 41.91 28.81 406.15 101.06 0.00 0.00 0.00 0.00 0.00 0.00 -2383.40 -221.11
F9 S1 APARTMENT 09-NOV-10:15 761.50 0.00 0.00 0.00 40.75 28.81 406.15 120.98 0.00 0.00 1044.65 0.00 0.00 0.00 -2402.84 0.00
F9 S2 APARTMENT 09-NOV-10:15 742.39 0.00 0.00 0.00 40.75 28.81 406.15 120.88 0.00 0.00 1064.25 0.00 0.00 0.00 -2403.22 0.00
T SW APARTMENT 17-JAN-04:00 2195.17 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 0.00 0.00 -1072.01 0.00 -1156.57 -394.33
T NW APARTMENT 14-DEC-04:00 2634.60 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 0.00 0.00 -1044.98 0.00 -1740.77 -276.60
T SE APARTMENT 17-JAN-04:00 2217.12 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 0.00 0.00 -1086.03 0.00 -1156.57 -402.26
T NE APARTMENT 14-DEC-04:00 2683.33 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 0.00 0.00 -1029.45 0.00 -1740.77 -340.86
T N1 APARTMENT 24-OCT-12:15 2124.88 0.00 0.00 0.00 40.75 28.81 388.49 384.47 0.00 0.00 0.00 0.00 0.00 0.00 -2165.05 -802.34
T N2 APARTMENT 24-OCT-12:15 2127.19 0.00 0.00 0.00 40.75 28.81 388.49 384.27 0.00 0.00 0.00 0.00 0.00 0.00 -2165.05 -804.45
T S1 APARTMENT 09-NOV-16:45 1443.11 0.00 0.00 0.00 56.90 100.83 470.89 0.00 0.00 0.00 528.17 0.00 -178.91 0.00 -2420.99 0.00
T S2 APARTMENT 09-NOV-16:45 1441.73 0.00 0.00 0.00 56.90 100.83 470.89 0.00 0.00 0.00 529.59 0.00 -178.95 0.00 -2420.99 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 18-JAN-01:30 80961.58 0.00 0.00 0.00 14984.05 7980.64 19245.24 0.00 0.00 0.00 2793.32 0.00 -68974.78 0.00 -56990.06 0.00



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Sec1.1A-General Information

Data
Weather File Albuquerque Intl Sunport NM USA TMY3 WMO#=723650
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 7836.48
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.50
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
F2 SW APARTMENT 88.25 88.25 0.00 168.00
F2 NW APARTMENT 88.25 88.25 0.00 168.00
F2 SE APARTMENT 88.25 88.25 0.00 168.00
F2 NE APARTMENT 88.25 88.25 0.00 168.00
F2 N1 APARTMENT 88.25 88.25 0.00 168.00
F2 N2 APARTMENT 88.25 88.25 0.00 168.00
F2 S1 APARTMENT 88.25 88.25 0.00 168.00
F2 S2 APARTMENT 88.25 88.25 0.00 168.00
F3 SW APARTMENT 88.25 88.25 0.00 168.00
F3 NW APARTMENT 88.25 88.25 0.00 168.00
F3 SE APARTMENT 88.25 88.25 0.00 168.00
F3 NE APARTMENT 88.25 88.25 0.00 168.00
F3 N1 APARTMENT 88.25 88.25 0.00 168.00
F3 N2 APARTMENT 88.25 88.25 0.00 168.00
F3 S1 APARTMENT 88.25 88.25 0.00 168.00
F3 S2 APARTMENT 88.25 88.25 0.00 168.00
F4 SW APARTMENT 88.25 88.25 0.00 168.00
F4 NW APARTMENT 88.25 88.25 0.00 168.00
F4 SE APARTMENT 88.25 88.25 0.00 168.00
F4 NE APARTMENT 88.25 88.25 0.00 168.00
F4 N1 APARTMENT 88.25 88.25 0.00 168.00
F4 N2 APARTMENT 88.25 88.25 0.00 168.00
F4 S1 APARTMENT 88.25 88.25 0.00 168.00
F4 S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
F6 SW APARTMENT 88.25 88.25 0.00 168.00
F6 NW APARTMENT 88.25 88.25 0.00 168.00
F6 SE APARTMENT 88.25 88.25 0.00 168.00
F6 NE APARTMENT 88.25 88.25 0.00 168.00
F6 N1 APARTMENT 88.25 88.25 0.00 168.00
F6 N2 APARTMENT 88.25 88.25 0.00 168.00
F6 S1 APARTMENT 88.25 88.25 0.00 168.00
F6 S2 APARTMENT 88.25 88.25 0.00 168.00
F7 SW APARTMENT 88.25 88.25 0.00 168.00
F7 NW APARTMENT 88.25 88.25 0.00 168.00
F7 SE APARTMENT 88.25 88.25 0.00 168.00
F7 NE APARTMENT 88.25 88.25 0.00 168.00
F7 N1 APARTMENT 88.25 88.25 0.00 168.00
F7 N2 APARTMENT 88.25 88.25 0.00 168.00
F7 S1 APARTMENT 88.25 88.25 0.00 168.00
F7 S2 APARTMENT 88.25 88.25 0.00 168.00
F8 SW APARTMENT 88.25 88.25 0.00 168.00
F8 NW APARTMENT 88.25 88.25 0.00 168.00
F8 SE APARTMENT 88.25 88.25 0.00 168.00
F8 NE APARTMENT 88.25 88.25 0.00 168.00
F8 N1 APARTMENT 88.25 88.25 0.00 168.00
F8 N2 APARTMENT 88.25 88.25 0.00 168.00
F8 S1 APARTMENT 88.25 88.25 0.00 168.00
F8 S2 APARTMENT 88.25 88.25 0.00 168.00
F9 SW APARTMENT 88.25 88.25 0.00 168.00
F9 NW APARTMENT 88.25 88.25 0.00 168.00
F9 SE APARTMENT 88.25 88.25 0.00 168.00
F9 NE APARTMENT 88.25 88.25 0.00 168.00
F9 N1 APARTMENT 88.25 88.25 0.00 168.00
F9 N2 APARTMENT 88.25 88.25 0.00 168.00
F9 S1 APARTMENT 88.25 88.25 0.00 168.00
F9 S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
G CORRIDOR 77.66 0.00 77.66 0.00
F2 CORRIDOR 77.66 0.00 77.66 0.00
F3 CORRIDOR 77.66 0.00 77.66 0.00
F4 CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
F6 CORRIDOR 77.66 0.00 77.66 0.00
F7 CORRIDOR 77.66 0.00 77.66 0.00
F8 CORRIDOR 77.66 0.00 77.66 0.00
F9 CORRIDOR 77.66 0.00 77.66 0.00
T CORRIDOR 77.66 0.00 77.66 0.00
Totals 7836.48 7059.89 776.58  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 83.00
Number of hours cooling loads not met 592.00
Number of hours not met 675.25


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 416.41 25049.15 0.00 0.00 0.00 0.00
Exterior Lighting 168.44 10720.10 0.00 0.00 0.00 0.00
Space Heating 39.47 0.00 85.75 87410.18 0.00 0.00
Space Cooling 543.05 59469.48 0.00 0.00 0.00 0.00
Pumps 43.59 1393.03 0.00 0.00 0.00 0.00
Heat Rejection 19.13 1879.51 0.00 0.00 0.00 0.00
Fans-Interior 699.65 22185.69 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 0.00 0.00 1107.29 86775.67 0.00 0.00
Receptacle Equipment 1131.09 49704.83 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 3081.65   1193.04   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 1131.09 3081.65
Natural Gas 0.00 1193.04
Additional 0.00 0.00
Total 1131.09 4274.69


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 53.14
Space Heating 5.04
Space Cooling 69.30
Fans-Interior 89.28
Service Water Heating 0.00
Receptacle Equipment 144.34
Miscellaneous 32.15
Subtotal 393.24


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 10.94
Service Water Heating 141.30
Miscellaneous -0.00
Subtotal 152.24


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 9.74
Space Heating 2.93
Space Cooling 12.70
Fans-Interior 16.37
Service Water Heating 25.90
Receptacle Equipment 26.46
Miscellaneous 5.89



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.258910
G NW APARTMENT DIRECT AIR 0.255012
OFFICE DIRECT AIR 0.327712
G NE APARTMENT DIRECT AIR 0.185878
G N1 APARTMENT DIRECT AIR 0.132973
G N2 APARTMENT DIRECT AIR 0.130982
G S1 APARTMENT DIRECT AIR 0.136322
G S2 APARTMENT DIRECT AIR 0.142188
F2 SW APARTMENT DIRECT AIR 0.333584
F2 NW APARTMENT DIRECT AIR 0.326109
F2 SE APARTMENT DIRECT AIR 0.289528
F2 NE APARTMENT DIRECT AIR 0.247149
F2 N1 APARTMENT DIRECT AIR 0.177396
F2 N2 APARTMENT DIRECT AIR 0.175768
F2 S1 APARTMENT DIRECT AIR 0.183880
F2 S2 APARTMENT DIRECT AIR 0.186098
F3 SW APARTMENT DIRECT AIR 0.335365
F3 NW APARTMENT DIRECT AIR 0.328661
F3 SE APARTMENT DIRECT AIR 0.273960
F3 NE APARTMENT DIRECT AIR 0.251176
F3 N1 APARTMENT DIRECT AIR 0.181470
F3 N2 APARTMENT DIRECT AIR 0.179856
F3 S1 APARTMENT DIRECT AIR 0.188061
F3 S2 APARTMENT DIRECT AIR 0.189196
F4 SW APARTMENT DIRECT AIR 0.336964
F4 NW APARTMENT DIRECT AIR 0.330385
F4 SE APARTMENT DIRECT AIR 0.274280
F4 NE APARTMENT DIRECT AIR 0.252823
F4 N1 APARTMENT DIRECT AIR 0.183508
F4 N2 APARTMENT DIRECT AIR 0.181900
F4 S1 APARTMENT DIRECT AIR 0.190023
F4 S2 APARTMENT DIRECT AIR 0.190976
M SW APARTMENT DIRECT AIR 0.341016
M NW APARTMENT DIRECT AIR 0.334616
M SE APARTMENT DIRECT AIR 0.278516
M NE APARTMENT DIRECT AIR 0.256935
M N1 APARTMENT DIRECT AIR 0.187784
M N2 APARTMENT DIRECT AIR 0.186181
M S1 APARTMENT DIRECT AIR 0.194174
M S2 APARTMENT DIRECT AIR 0.195086
F6 SW APARTMENT DIRECT AIR 0.337333
F6 NW APARTMENT DIRECT AIR 0.330882
F6 SE APARTMENT DIRECT AIR 0.275301
F6 NE APARTMENT DIRECT AIR 0.253245
F6 N1 APARTMENT DIRECT AIR 0.184445
F6 N2 APARTMENT DIRECT AIR 0.182854
F6 S1 APARTMENT DIRECT AIR 0.190827
F6 S2 APARTMENT DIRECT AIR 0.191718
F7 SW APARTMENT DIRECT AIR 0.336398
F7 NW APARTMENT DIRECT AIR 0.330018
F7 SE APARTMENT DIRECT AIR 0.274776
F7 NE APARTMENT DIRECT AIR 0.252366
F7 N1 APARTMENT DIRECT AIR 0.183802
F7 N2 APARTMENT DIRECT AIR 0.182219
F7 S1 APARTMENT DIRECT AIR 0.190098
F7 S2 APARTMENT DIRECT AIR 0.190972
F8 SW APARTMENT DIRECT AIR 0.337093
F8 NW APARTMENT DIRECT AIR 0.330781
F8 SE APARTMENT DIRECT AIR 0.275720
F8 NE APARTMENT DIRECT AIR 0.252998
F8 N1 APARTMENT DIRECT AIR 0.184753
F8 N2 APARTMENT DIRECT AIR 0.183180
F8 S1 APARTMENT DIRECT AIR 0.190874
F8 S2 APARTMENT DIRECT AIR 0.191734
F9 SW APARTMENT DIRECT AIR 0.349150
F9 NW APARTMENT DIRECT AIR 0.342849
F9 SE APARTMENT DIRECT AIR 0.284561
F9 NE APARTMENT DIRECT AIR 0.257598
F9 N1 APARTMENT DIRECT AIR 0.195323
F9 N2 APARTMENT DIRECT AIR 0.193734
F9 S1 APARTMENT DIRECT AIR 0.198443
F9 S2 APARTMENT DIRECT AIR 0.199351
T SW APARTMENT DIRECT AIR 0.430106
T NW APARTMENT DIRECT AIR 0.418217
T SE APARTMENT DIRECT AIR 0.366917
T NE APARTMENT DIRECT AIR 0.324820
T N1 APARTMENT DIRECT AIR 0.248549
T N2 APARTMENT DIRECT AIR 0.248245
T S1 APARTMENT DIRECT AIR 0.290618
T S2 APARTMENT DIRECT AIR 0.291477


Branch

Maximum Flow Rate [m3/s]
AIRLOOP G SW MAIN BRANCH 0.258910
AIRLOOP G NW MAIN BRANCH 0.255012
AIRLOOP OFFICE MAIN BRANCH 0.327712
AIRLOOP G NE MAIN BRANCH 0.185878
AIRLOOP G N1 MAIN BRANCH 0.132973
AIRLOOP G N2 MAIN BRANCH 0.130982
AIRLOOP G S1 MAIN BRANCH 0.136322
AIRLOOP G S2 MAIN BRANCH 0.142188
AIRLOOP F2 SW MAIN BRANCH 0.333584
AIRLOOP F2 NW MAIN BRANCH 0.326109
AIRLOOP F2 SE MAIN BRANCH 0.289528
AIRLOOP F2 NE MAIN BRANCH 0.247149
AIRLOOP F2 N1 MAIN BRANCH 0.177396
AIRLOOP F2 N2 MAIN BRANCH 0.175768
AIRLOOP F2 S1 MAIN BRANCH 0.183880
AIRLOOP F2 S2 MAIN BRANCH 0.186098
AIRLOOP F3 SW MAIN BRANCH 0.335365
AIRLOOP F3 NW MAIN BRANCH 0.328661
AIRLOOP F3 SE MAIN BRANCH 0.273960
AIRLOOP F3 NE MAIN BRANCH 0.251176
AIRLOOP F3 N1 MAIN BRANCH 0.181470
AIRLOOP F3 N2 MAIN BRANCH 0.179856
AIRLOOP F3 S1 MAIN BRANCH 0.188061
AIRLOOP F3 S2 MAIN BRANCH 0.189196
AIRLOOP F4 SW MAIN BRANCH 0.336964
AIRLOOP F4 NW MAIN BRANCH 0.330385
AIRLOOP F4 SE MAIN BRANCH 0.274280
AIRLOOP F4 NE MAIN BRANCH 0.252823
AIRLOOP F4 N1 MAIN BRANCH 0.183508
AIRLOOP F4 N2 MAIN BRANCH 0.181900
AIRLOOP F4 S1 MAIN BRANCH 0.190023
AIRLOOP F4 S2 MAIN BRANCH 0.190976
AIRLOOP M SW MAIN BRANCH 0.341016
AIRLOOP M NW MAIN BRANCH 0.334616
AIRLOOP M SE MAIN BRANCH 0.278516
AIRLOOP M NE MAIN BRANCH 0.256935
AIRLOOP M N1 MAIN BRANCH 0.187784
AIRLOOP M N2 MAIN BRANCH 0.186181
AIRLOOP M S1 MAIN BRANCH 0.194174
AIRLOOP M S2 MAIN BRANCH 0.195086
AIRLOOP F6 SW MAIN BRANCH 0.337333
AIRLOOP F6 NW MAIN BRANCH 0.330882
AIRLOOP F6 SE MAIN BRANCH 0.275301
AIRLOOP F6 NE MAIN BRANCH 0.253245
AIRLOOP F6 N1 MAIN BRANCH 0.184445
AIRLOOP F6 N2 MAIN BRANCH 0.182854
AIRLOOP F6 S1 MAIN BRANCH 0.190827
AIRLOOP F6 S2 MAIN BRANCH 0.191718
AIRLOOP F7 SW MAIN BRANCH 0.336398
AIRLOOP F7 NW MAIN BRANCH 0.330018
AIRLOOP F7 SE MAIN BRANCH 0.274776
AIRLOOP F7 NE MAIN BRANCH 0.252366
AIRLOOP F7 N1 MAIN BRANCH 0.183802
AIRLOOP F7 N2 MAIN BRANCH 0.182219
AIRLOOP F7 S1 MAIN BRANCH 0.190098
AIRLOOP F7 S2 MAIN BRANCH 0.190972
AIRLOOP F8 SW MAIN BRANCH 0.337093
AIRLOOP F8 NW MAIN BRANCH 0.330781
AIRLOOP F8 SE MAIN BRANCH 0.275720
AIRLOOP F8 NE MAIN BRANCH 0.252998
AIRLOOP F8 N1 MAIN BRANCH 0.184753
AIRLOOP F8 N2 MAIN BRANCH 0.183180
AIRLOOP F8 S1 MAIN BRANCH 0.190874
AIRLOOP F8 S2 MAIN BRANCH 0.191734
AIRLOOP F9 SW MAIN BRANCH 0.349150
AIRLOOP F9 NW MAIN BRANCH 0.342849
AIRLOOP F9 SE MAIN BRANCH 0.284561
AIRLOOP F9 NE MAIN BRANCH 0.257598
AIRLOOP F9 N1 MAIN BRANCH 0.195323
AIRLOOP F9 N2 MAIN BRANCH 0.193734
AIRLOOP F9 S1 MAIN BRANCH 0.198443
AIRLOOP F9 S2 MAIN BRANCH 0.199351
AIRLOOP T SW MAIN BRANCH 0.430106
AIRLOOP T NW MAIN BRANCH 0.418217
AIRLOOP T SE MAIN BRANCH 0.366917
AIRLOOP T NE MAIN BRANCH 0.324820
AIRLOOP T N1 MAIN BRANCH 0.248549
AIRLOOP T N2 MAIN BRANCH 0.248245
AIRLOOP T S1 MAIN BRANCH 0.290618
AIRLOOP T S2 MAIN BRANCH 0.291477


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
AIRLOOP G SW 0.258910
AIRLOOP G NW 0.255012
AIRLOOP OFFICE 0.327712
AIRLOOP G NE 0.185878
AIRLOOP G N1 0.132973
AIRLOOP G N2 0.130982
AIRLOOP G S1 0.136322
AIRLOOP G S2 0.142188
AIRLOOP F2 SW 0.333584
AIRLOOP F2 NW 0.326109
AIRLOOP F2 SE 0.289528
AIRLOOP F2 NE 0.247149
AIRLOOP F2 N1 0.177396
AIRLOOP F2 N2 0.175768
AIRLOOP F2 S1 0.183880
AIRLOOP F2 S2 0.186098
AIRLOOP F3 SW 0.335365
AIRLOOP F3 NW 0.328661
AIRLOOP F3 SE 0.273960
AIRLOOP F3 NE 0.251176
AIRLOOP F3 N1 0.181470
AIRLOOP F3 N2 0.179856
AIRLOOP F3 S1 0.188061
AIRLOOP F3 S2 0.189196
AIRLOOP F4 SW 0.336964
AIRLOOP F4 NW 0.330385
AIRLOOP F4 SE 0.274280
AIRLOOP F4 NE 0.252823
AIRLOOP F4 N1 0.183508
AIRLOOP F4 N2 0.181900
AIRLOOP F4 S1 0.190023
AIRLOOP F4 S2 0.190976
AIRLOOP M SW 0.341016
AIRLOOP M NW 0.334616
AIRLOOP M SE 0.278516
AIRLOOP M NE 0.256935
AIRLOOP M N1 0.187784
AIRLOOP M N2 0.186181
AIRLOOP M S1 0.194174
AIRLOOP M S2 0.195086
AIRLOOP F6 SW 0.337333
AIRLOOP F6 NW 0.330882
AIRLOOP F6 SE 0.275301
AIRLOOP F6 NE 0.253245
AIRLOOP F6 N1 0.184445
AIRLOOP F6 N2 0.182854
AIRLOOP F6 S1 0.190827
AIRLOOP F6 S2 0.191718
AIRLOOP F7 SW 0.336398
AIRLOOP F7 NW 0.330018
AIRLOOP F7 SE 0.274776
AIRLOOP F7 NE 0.252366
AIRLOOP F7 N1 0.183802
AIRLOOP F7 N2 0.182219
AIRLOOP F7 S1 0.190098
AIRLOOP F7 S2 0.190972
AIRLOOP F8 SW 0.337093
AIRLOOP F8 NW 0.330781
AIRLOOP F8 SE 0.275720
AIRLOOP F8 NE 0.252998
AIRLOOP F8 N1 0.184753
AIRLOOP F8 N2 0.183180
AIRLOOP F8 S1 0.190874
AIRLOOP F8 S2 0.191734
AIRLOOP F9 SW 0.349150
AIRLOOP F9 NW 0.342849
AIRLOOP F9 SE 0.284561
AIRLOOP F9 NE 0.257598
AIRLOOP F9 N1 0.195323
AIRLOOP F9 N2 0.193734
AIRLOOP F9 S1 0.198443
AIRLOOP F9 S2 0.199351
AIRLOOP T SW 0.430106
AIRLOOP T NW 0.418217
AIRLOOP T SE 0.366917
AIRLOOP T NE 0.324820
AIRLOOP T N1 0.248549
AIRLOOP T N2 0.248245
AIRLOOP T S1 0.290618
AIRLOOP T S2 0.291477


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
AIRLOOP G SW OA CONTROLLER 0.258910 0.025952
AIRLOOP G NW OA CONTROLLER 0.255012 0.025952
AIRLOOP OFFICE OA CONTROLLER 0.327712 0.038103
AIRLOOP G NE OA CONTROLLER 0.185878 0.025952
AIRLOOP G N1 OA CONTROLLER 0.132973 0.025952
AIRLOOP G N2 OA CONTROLLER 0.130982 0.025952
AIRLOOP G S1 OA CONTROLLER 0.136322 0.025952
AIRLOOP G S2 OA CONTROLLER 0.142188 0.025952
AIRLOOP F2 SW OA CONTROLLER 0.333584 0.025952
AIRLOOP F2 NW OA CONTROLLER 0.326109 0.025952
AIRLOOP F2 SE OA CONTROLLER 0.289528 0.025952
AIRLOOP F2 NE OA CONTROLLER 0.247149 0.025952
AIRLOOP F2 N1 OA CONTROLLER 0.177396 0.025952
AIRLOOP F2 N2 OA CONTROLLER 0.175768 0.025952
AIRLOOP F2 S1 OA CONTROLLER 0.183880 0.025952
AIRLOOP F2 S2 OA CONTROLLER 0.186098 0.025952
AIRLOOP F3 SW OA CONTROLLER 0.335365 0.025952
AIRLOOP F3 NW OA CONTROLLER 0.328661 0.025952
AIRLOOP F3 SE OA CONTROLLER 0.273960 0.025952
AIRLOOP F3 NE OA CONTROLLER 0.251176 0.025952
AIRLOOP F3 N1 OA CONTROLLER 0.181470 0.025952
AIRLOOP F3 N2 OA CONTROLLER 0.179856 0.025952
AIRLOOP F3 S1 OA CONTROLLER 0.188061 0.025952
AIRLOOP F3 S2 OA CONTROLLER 0.189196 0.025952
AIRLOOP F4 SW OA CONTROLLER 0.336964 0.025952
AIRLOOP F4 NW OA CONTROLLER 0.330385 0.025952
AIRLOOP F4 SE OA CONTROLLER 0.274280 0.025952
AIRLOOP F4 NE OA CONTROLLER 0.252823 0.025952
AIRLOOP F4 N1 OA CONTROLLER 0.183508 0.025952
AIRLOOP F4 N2 OA CONTROLLER 0.181900 0.025952
AIRLOOP F4 S1 OA CONTROLLER 0.190023 0.025952
AIRLOOP F4 S2 OA CONTROLLER 0.190976 0.025952
AIRLOOP M SW OA CONTROLLER 0.341016 0.025952
AIRLOOP M NW OA CONTROLLER 0.334616 0.025952
AIRLOOP M SE OA CONTROLLER 0.278516 0.025952
AIRLOOP M NE OA CONTROLLER 0.256935 0.025952
AIRLOOP M N1 OA CONTROLLER 0.187784 0.025952
AIRLOOP M N2 OA CONTROLLER 0.186181 0.025952
AIRLOOP M S1 OA CONTROLLER 0.194174 0.025952
AIRLOOP M S2 OA CONTROLLER 0.195086 0.025952
AIRLOOP F6 SW OA CONTROLLER 0.337333 0.025952
AIRLOOP F6 NW OA CONTROLLER 0.330882 0.025952
AIRLOOP F6 SE OA CONTROLLER 0.275301 0.025952
AIRLOOP F6 NE OA CONTROLLER 0.253245 0.025952
AIRLOOP F6 N1 OA CONTROLLER 0.184445 0.025952
AIRLOOP F6 N2 OA CONTROLLER 0.182854 0.025952
AIRLOOP F6 S1 OA CONTROLLER 0.190827 0.025952
AIRLOOP F6 S2 OA CONTROLLER 0.191718 0.025952
AIRLOOP F7 SW OA CONTROLLER 0.336398 0.025952
AIRLOOP F7 NW OA CONTROLLER 0.330018 0.025952
AIRLOOP F7 SE OA CONTROLLER 0.274776 0.025952
AIRLOOP F7 NE OA CONTROLLER 0.252366 0.025952
AIRLOOP F7 N1 OA CONTROLLER 0.183802 0.025952
AIRLOOP F7 N2 OA CONTROLLER 0.182219 0.025952
AIRLOOP F7 S1 OA CONTROLLER 0.190098 0.025952
AIRLOOP F7 S2 OA CONTROLLER 0.190972 0.025952
AIRLOOP F8 SW OA CONTROLLER 0.337093 0.025952
AIRLOOP F8 NW OA CONTROLLER 0.330781 0.025952
AIRLOOP F8 SE OA CONTROLLER 0.275720 0.025952
AIRLOOP F8 NE OA CONTROLLER 0.252998 0.025952
AIRLOOP F8 N1 OA CONTROLLER 0.184753 0.025952
AIRLOOP F8 N2 OA CONTROLLER 0.183180 0.025952
AIRLOOP F8 S1 OA CONTROLLER 0.190874 0.025952
AIRLOOP F8 S2 OA CONTROLLER 0.191734 0.025952
AIRLOOP F9 SW OA CONTROLLER 0.349150 0.025952
AIRLOOP F9 NW OA CONTROLLER 0.342849 0.025952
AIRLOOP F9 SE OA CONTROLLER 0.284561 0.025952
AIRLOOP F9 NE OA CONTROLLER 0.257598 0.025952
AIRLOOP F9 N1 OA CONTROLLER 0.195323 0.025952
AIRLOOP F9 N2 OA CONTROLLER 0.193734 0.025952
AIRLOOP F9 S1 OA CONTROLLER 0.198443 0.025952
AIRLOOP F9 S2 OA CONTROLLER 0.199351 0.025952
AIRLOOP T SW OA CONTROLLER 0.430106 0.025952
AIRLOOP T NW OA CONTROLLER 0.418217 0.025952
AIRLOOP T SE OA CONTROLLER 0.366917 0.025952
AIRLOOP T NE OA CONTROLLER 0.324820 0.025952
AIRLOOP T N1 OA CONTROLLER 0.248549 0.025952
AIRLOOP T N2 OA CONTROLLER 0.248245 0.025952
AIRLOOP T S1 OA CONTROLLER 0.290618 0.025952
AIRLOOP T S2 OA CONTROLLER 0.291477 0.025952


COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity [W] Rated Sensible Cooling Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP COOLING MODE AIRLOOP G SW 0.258910 3205.74 2069.43 0.000070
HEAT PUMP COOLING MODE AIRLOOP G NW 0.255012 3148.90 2033.46 0.000069
HEAT PUMP COOLING MODE AIRLOOP OFFICE 0.327712 4016.33 2614.97 0.000088
HEAT PUMP COOLING MODE AIRLOOP G NE 0.185878 2247.30 1476.51 0.000049
HEAT PUMP COOLING MODE AIRLOOP G N1 0.132973 1649.01 1075.73 0.000036
HEAT PUMP COOLING MODE AIRLOOP G N2 0.130982 1624.43 1060.20 0.000035
HEAT PUMP COOLING MODE AIRLOOP G S1 0.136322 1773.44 1138.37 0.000039
HEAT PUMP COOLING MODE AIRLOOP G S2 0.142188 1845.11 1184.20 0.000040
HEAT PUMP COOLING MODE AIRLOOP F2 SW 0.333584 4097.56 2645.61 0.000090
HEAT PUMP COOLING MODE AIRLOOP F2 NW 0.326109 3998.19 2581.99 0.000087
HEAT PUMP COOLING MODE AIRLOOP F2 SE 0.289528 3602.22 2322.51 0.000079
HEAT PUMP COOLING MODE AIRLOOP F2 NE 0.247149 2973.18 1948.25 0.000065
HEAT PUMP COOLING MODE AIRLOOP F2 N1 0.177396 2184.74 1419.81 0.000048
HEAT PUMP COOLING MODE AIRLOOP F2 N2 0.175768 2164.71 1407.14 0.000047
HEAT PUMP COOLING MODE AIRLOOP F2 S1 0.183880 2347.31 1509.03 0.000051
HEAT PUMP COOLING MODE AIRLOOP F2 S2 0.186098 2369.96 1524.60 0.000052
HEAT PUMP COOLING MODE AIRLOOP F3 SW 0.335365 4106.84 2657.32 0.000090
HEAT PUMP COOLING MODE AIRLOOP F3 NW 0.328661 4016.93 2599.68 0.000088
HEAT PUMP COOLING MODE AIRLOOP F3 SE 0.273960 3400.35 2199.59 0.000074
HEAT PUMP COOLING MODE AIRLOOP F3 NE 0.251176 3010.14 1977.45 0.000066
HEAT PUMP COOLING MODE AIRLOOP F3 N1 0.181470 2227.65 1450.30 0.000049
HEAT PUMP COOLING MODE AIRLOOP F3 N2 0.179856 2207.81 1437.74 0.000048
HEAT PUMP COOLING MODE AIRLOOP F3 S1 0.188061 2391.41 1540.41 0.000052
HEAT PUMP COOLING MODE AIRLOOP F3 S2 0.189196 2400.81 1547.54 0.000052
HEAT PUMP COOLING MODE AIRLOOP F4 SW 0.336964 4117.02 2668.14 0.000090
HEAT PUMP COOLING MODE AIRLOOP F4 NW 0.330385 4028.65 2611.48 0.000088
HEAT PUMP COOLING MODE AIRLOOP F4 SE 0.274280 3395.33 2200.57 0.000074
HEAT PUMP COOLING MODE AIRLOOP F4 NE 0.252823 3034.38 1994.12 0.000066
HEAT PUMP COOLING MODE AIRLOOP F4 N1 0.183508 2247.30 1465.24 0.000049
HEAT PUMP COOLING MODE AIRLOOP F4 N2 0.181900 2227.55 1452.73 0.000049
HEAT PUMP COOLING MODE AIRLOOP F4 S1 0.190023 2410.14 1554.80 0.000053
HEAT PUMP COOLING MODE AIRLOOP F4 S2 0.190976 2417.30 1560.51 0.000053
HEAT PUMP COOLING MODE AIRLOOP M SW 0.341016 4158.84 2698.28 0.000091
HEAT PUMP COOLING MODE AIRLOOP M NW 0.334616 4072.71 2643.02 0.000089
HEAT PUMP COOLING MODE AIRLOOP M SE 0.278516 3439.66 2232.22 0.000075
HEAT PUMP COOLING MODE AIRLOOP M NE 0.256935 3077.10 2024.77 0.000067
HEAT PUMP COOLING MODE AIRLOOP M N1 0.187784 2295.42 1497.75 0.000050
HEAT PUMP COOLING MODE AIRLOOP M N2 0.186181 2275.75 1485.29 0.000050
HEAT PUMP COOLING MODE AIRLOOP M S1 0.194174 2456.49 1586.38 0.000054
HEAT PUMP COOLING MODE AIRLOOP M S2 0.195086 2463.12 1591.76 0.000054
HEAT PUMP COOLING MODE AIRLOOP F6 SW 0.337333 4107.38 2668.62 0.000090
HEAT PUMP COOLING MODE AIRLOOP F6 NW 0.330882 4020.59 2612.95 0.000088
HEAT PUMP COOLING MODE AIRLOOP F6 SE 0.275301 3398.79 2207.99 0.000074
HEAT PUMP COOLING MODE AIRLOOP F6 NE 0.253245 3025.97 1995.13 0.000066
HEAT PUMP COOLING MODE AIRLOOP F6 N1 0.184445 2250.64 1471.15 0.000049
HEAT PUMP COOLING MODE AIRLOOP F6 N2 0.182854 2231.12 1458.78 0.000049
HEAT PUMP COOLING MODE AIRLOOP F6 S1 0.190827 2412.06 1559.73 0.000053
HEAT PUMP COOLING MODE AIRLOOP F6 S2 0.191718 2418.41 1564.94 0.000053
HEAT PUMP COOLING MODE AIRLOOP F7 SW 0.336398 4090.25 2660.39 0.000089
HEAT PUMP COOLING MODE AIRLOOP F7 NW 0.330018 4004.31 2605.28 0.000087
HEAT PUMP COOLING MODE AIRLOOP F7 SE 0.274776 3386.97 2203.00 0.000074
HEAT PUMP COOLING MODE AIRLOOP F7 NE 0.252366 3009.82 1987.41 0.000066
HEAT PUMP COOLING MODE AIRLOOP F7 N1 0.183802 2239.43 1465.59 0.000049
HEAT PUMP COOLING MODE AIRLOOP F7 N2 0.182219 2220.02 1453.29 0.000048
HEAT PUMP COOLING MODE AIRLOOP F7 S1 0.190098 2399.99 1553.51 0.000052
HEAT PUMP COOLING MODE AIRLOOP F7 S2 0.190972 2406.11 1558.60 0.000053
HEAT PUMP COOLING MODE AIRLOOP F8 SW 0.337093 4093.59 2664.92 0.000089
HEAT PUMP COOLING MODE AIRLOOP F8 NW 0.330781 4008.49 2610.33 0.000088
HEAT PUMP COOLING MODE AIRLOOP F8 SE 0.275720 3393.58 2209.50 0.000074
HEAT PUMP COOLING MODE AIRLOOP F8 NE 0.252998 3012.60 1991.48 0.000066
HEAT PUMP COOLING MODE AIRLOOP F8 N1 0.184753 2248.14 1472.49 0.000049
HEAT PUMP COOLING MODE AIRLOOP F8 N2 0.183180 2228.86 1460.27 0.000049
HEAT PUMP COOLING MODE AIRLOOP F8 S1 0.190874 2406.58 1559.07 0.000053
HEAT PUMP COOLING MODE AIRLOOP F8 S2 0.191734 2412.52 1564.04 0.000053
HEAT PUMP COOLING MODE AIRLOOP F9 SW 0.349150 4235.91 2757.64 0.000093
HEAT PUMP COOLING MODE AIRLOOP F9 NW 0.342849 4151.08 2703.15 0.000091
HEAT PUMP COOLING MODE AIRLOOP F9 SE 0.284561 3496.63 2277.35 0.000076
HEAT PUMP COOLING MODE AIRLOOP F9 NE 0.257598 3063.96 2026.37 0.000067
HEAT PUMP COOLING MODE AIRLOOP F9 N1 0.195323 2375.11 1554.21 0.000052
HEAT PUMP COOLING MODE AIRLOOP F9 N2 0.193734 2355.64 1541.86 0.000051
HEAT PUMP COOLING MODE AIRLOOP F9 S1 0.198443 2496.23 1617.52 0.000055
HEAT PUMP COOLING MODE AIRLOOP F9 S2 0.199351 2507.13 1624.55 0.000055
HEAT PUMP COOLING MODE AIRLOOP T SW 0.430106 5241.32 3395.82 0.000114
HEAT PUMP COOLING MODE AIRLOOP T NW 0.418217 5079.47 3295.62 0.000111
HEAT PUMP COOLING MODE AIRLOOP T SE 0.366917 4495.28 2915.56 0.000098
HEAT PUMP COOLING MODE AIRLOOP T NE 0.324820 3904.45 2557.56 0.000085
HEAT PUMP COOLING MODE AIRLOOP T N1 0.248549 3104.20 2006.55 0.000068
HEAT PUMP COOLING MODE AIRLOOP T N2 0.248245 3100.56 2004.20 0.000068
HEAT PUMP COOLING MODE AIRLOOP T S1 0.290618 3617.14 2333.28 0.000079
HEAT PUMP COOLING MODE AIRLOOP T S2 0.291477 3623.11 2338.17 0.000079


AirLoopHVAC:UnitaryHeatPump:WaterToAir

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Supplemental Heating Coil Nominal Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
AIRLOOP G SW DXAC HEAT PUMP 0.258910 0.258910 0.258910 0.258910 3205.74 3205.74 2438.18 1.00
AIRLOOP G NW DXAC HEAT PUMP 0.255012 0.255012 0.255012 0.255012 3148.90 3148.90 2437.28 1.00
AIRLOOP OFFICE DXAC HEAT PUMP 0.327712 0.327712 0.327712 0.327712 4016.33 4016.33 3204.67 1.00
AIRLOOP G NE DXAC HEAT PUMP 0.185878 0.185878 0.185878 0.185878 2247.30 2247.30 2437.28 1.00
AIRLOOP G N1 DXAC HEAT PUMP 0.132973 0.132973 0.132973 0.132973 1649.01 1649.01 1803.85 1.00
AIRLOOP G N2 DXAC HEAT PUMP 0.130982 0.130982 0.130982 0.130982 1624.43 1624.43 1803.85 1.00
AIRLOOP G S1 DXAC HEAT PUMP 0.136322 0.136322 0.136322 0.136322 1773.44 1773.44 1801.10 1.00
AIRLOOP G S2 DXAC HEAT PUMP 0.142188 0.142188 0.142188 0.142188 1845.11 1845.11 1809.61 1.00
AIRLOOP F2 SW DXAC HEAT PUMP 0.333584 0.333584 0.333584 0.333584 4097.56 4097.56 2417.40 1.00
AIRLOOP F2 NW DXAC HEAT PUMP 0.326109 0.326109 0.326109 0.326109 3998.19 3998.19 2415.07 1.00
AIRLOOP F2 SE DXAC HEAT PUMP 0.289528 0.289528 0.289528 0.289528 3602.22 3602.22 2442.87 1.00
AIRLOOP F2 NE DXAC HEAT PUMP 0.247149 0.247149 0.247149 0.247149 2973.18 2973.18 2415.07 1.00
AIRLOOP F2 N1 DXAC HEAT PUMP 0.177396 0.177396 0.177396 0.177396 2184.74 2184.74 1636.45 1.00
AIRLOOP F2 N2 DXAC HEAT PUMP 0.175768 0.175768 0.175768 0.175768 2164.71 2164.71 1636.45 1.00
AIRLOOP F2 S1 DXAC HEAT PUMP 0.183880 0.183880 0.183880 0.183880 2347.31 2347.31 1641.48 1.00
AIRLOOP F2 S2 DXAC HEAT PUMP 0.186098 0.186098 0.186098 0.186098 2369.96 2369.96 1643.18 1.00
AIRLOOP F3 SW DXAC HEAT PUMP 0.335365 0.335365 0.335365 0.335365 4106.84 4106.84 2408.10 1.00
AIRLOOP F3 NW DXAC HEAT PUMP 0.328661 0.328661 0.328661 0.328661 4016.93 4016.93 2408.73 1.00
AIRLOOP F3 SE DXAC HEAT PUMP 0.273960 0.273960 0.273960 0.273960 3400.35 3400.35 2410.95 1.00
AIRLOOP F3 NE DXAC HEAT PUMP 0.251176 0.251176 0.251176 0.251176 3010.14 3010.14 2408.73 1.00
AIRLOOP F3 N1 DXAC HEAT PUMP 0.181470 0.181470 0.181470 0.181470 2227.65 2227.65 1603.57 1.00
AIRLOOP F3 N2 DXAC HEAT PUMP 0.179856 0.179856 0.179856 0.179856 2207.81 2207.81 1603.57 1.00
AIRLOOP F3 S1 DXAC HEAT PUMP 0.188061 0.188061 0.188061 0.188061 2391.41 2391.41 1603.68 1.00
AIRLOOP F3 S2 DXAC HEAT PUMP 0.189196 0.189196 0.189196 0.189196 2400.81 2400.81 1603.96 1.00
AIRLOOP F4 SW DXAC HEAT PUMP 0.336964 0.336964 0.336964 0.336964 4117.02 4117.02 2437.51 1.00
AIRLOOP F4 NW DXAC HEAT PUMP 0.330385 0.330385 0.330385 0.330385 4028.65 4028.65 2440.24 1.00
AIRLOOP F4 SE DXAC HEAT PUMP 0.274280 0.274280 0.274280 0.274280 3395.33 3395.33 2437.81 1.00
AIRLOOP F4 NE DXAC HEAT PUMP 0.252823 0.252823 0.252823 0.252823 3034.38 3034.38 2440.24 1.00
AIRLOOP F4 N1 DXAC HEAT PUMP 0.183508 0.183508 0.183508 0.183508 2247.30 2247.30 1613.44 1.00
AIRLOOP F4 N2 DXAC HEAT PUMP 0.181900 0.181900 0.181900 0.181900 2227.55 2227.55 1613.44 1.00
AIRLOOP F4 S1 DXAC HEAT PUMP 0.190023 0.190023 0.190023 0.190023 2410.14 2410.14 1611.18 1.00
AIRLOOP F4 S2 DXAC HEAT PUMP 0.190976 0.190976 0.190976 0.190976 2417.30 2417.30 1611.22 1.00
AIRLOOP M SW DXAC HEAT PUMP 0.341016 0.341016 0.341016 0.341016 4158.84 4158.84 2444.07 1.00
AIRLOOP M NW DXAC HEAT PUMP 0.334616 0.334616 0.334616 0.334616 4072.71 4072.71 2447.13 1.00
AIRLOOP M SE DXAC HEAT PUMP 0.278516 0.278516 0.278516 0.278516 3439.66 3439.66 2444.10 1.00
AIRLOOP M NE DXAC HEAT PUMP 0.256935 0.256935 0.256935 0.256935 3077.10 3077.10 2447.13 1.00
AIRLOOP M N1 DXAC HEAT PUMP 0.187784 0.187784 0.187784 0.187784 2295.42 2295.42 1605.70 1.00
AIRLOOP M N2 DXAC HEAT PUMP 0.186181 0.186181 0.186181 0.186181 2275.75 2275.75 1605.70 1.00
AIRLOOP M S1 DXAC HEAT PUMP 0.194174 0.194174 0.194174 0.194174 2456.49 2456.49 1603.05 1.00
AIRLOOP M S2 DXAC HEAT PUMP 0.195086 0.195086 0.195086 0.195086 2463.12 2463.12 1603.05 1.00
AIRLOOP F6 SW DXAC HEAT PUMP 0.337333 0.337333 0.337333 0.337333 4107.38 4107.38 2518.98 1.00
AIRLOOP F6 NW DXAC HEAT PUMP 0.330882 0.330882 0.330882 0.330882 4020.59 4020.59 2524.13 1.00
AIRLOOP F6 SE DXAC HEAT PUMP 0.275301 0.275301 0.275301 0.275301 3398.79 3398.79 2518.98 1.00
AIRLOOP F6 NE DXAC HEAT PUMP 0.253245 0.253245 0.253245 0.253245 3025.97 3025.97 2524.13 1.00
AIRLOOP F6 N1 DXAC HEAT PUMP 0.184445 0.184445 0.184445 0.184445 2250.64 2250.64 1664.53 1.00
AIRLOOP F6 N2 DXAC HEAT PUMP 0.182854 0.182854 0.182854 0.182854 2231.12 2231.12 1664.53 1.00
AIRLOOP F6 S1 DXAC HEAT PUMP 0.190827 0.190827 0.190827 0.190827 2412.06 2412.06 1659.73 1.00
AIRLOOP F6 S2 DXAC HEAT PUMP 0.191718 0.191718 0.191718 0.191718 2418.41 2418.41 1659.73 1.00
AIRLOOP F7 SW DXAC HEAT PUMP 0.336398 0.336398 0.336398 0.336398 4090.25 4090.25 2566.03 1.00
AIRLOOP F7 NW DXAC HEAT PUMP 0.330018 0.330018 0.330018 0.330018 4004.31 4004.31 2571.88 1.00
AIRLOOP F7 SE DXAC HEAT PUMP 0.274776 0.274776 0.274776 0.274776 3386.97 3386.97 2566.03 1.00
AIRLOOP F7 NE DXAC HEAT PUMP 0.252366 0.252366 0.252366 0.252366 3009.82 3009.82 2571.88 1.00
AIRLOOP F7 N1 DXAC HEAT PUMP 0.183802 0.183802 0.183802 0.183802 2239.43 2239.43 1699.07 1.00
AIRLOOP F7 N2 DXAC HEAT PUMP 0.182219 0.182219 0.182219 0.182219 2220.02 2220.02 1699.07 1.00
AIRLOOP F7 S1 DXAC HEAT PUMP 0.190098 0.190098 0.190098 0.190098 2399.99 2399.99 1693.52 1.00
AIRLOOP F7 S2 DXAC HEAT PUMP 0.190972 0.190972 0.190972 0.190972 2406.11 2406.11 1693.52 1.00
AIRLOOP F8 SW DXAC HEAT PUMP 0.337093 0.337093 0.337093 0.337093 4093.59 4093.59 2617.09 1.00
AIRLOOP F8 NW DXAC HEAT PUMP 0.330781 0.330781 0.330781 0.330781 4008.49 4008.49 2623.31 1.00
AIRLOOP F8 SE DXAC HEAT PUMP 0.275720 0.275720 0.275720 0.275720 3393.58 3393.58 2617.09 1.00
AIRLOOP F8 NE DXAC HEAT PUMP 0.252998 0.252998 0.252998 0.252998 3012.60 3012.60 2623.31 1.00
AIRLOOP F8 N1 DXAC HEAT PUMP 0.184753 0.184753 0.184753 0.184753 2248.14 2248.14 1739.23 1.00
AIRLOOP F8 N2 DXAC HEAT PUMP 0.183180 0.183180 0.183180 0.183180 2228.86 2228.86 1739.23 1.00
AIRLOOP F8 S1 DXAC HEAT PUMP 0.190874 0.190874 0.190874 0.190874 2406.58 2406.58 1733.27 1.00
AIRLOOP F8 S2 DXAC HEAT PUMP 0.191734 0.191734 0.191734 0.191734 2412.52 2412.52 1733.27 1.00
AIRLOOP F9 SW DXAC HEAT PUMP 0.349150 0.349150 0.349150 0.349150 4235.91 4235.91 2787.45 1.00
AIRLOOP F9 NW DXAC HEAT PUMP 0.342849 0.342849 0.342849 0.342849 4151.08 4151.08 2791.65 1.00
AIRLOOP F9 SE DXAC HEAT PUMP 0.284561 0.284561 0.284561 0.284561 3496.63 3496.63 2787.45 1.00
AIRLOOP F9 NE DXAC HEAT PUMP 0.257598 0.257598 0.257598 0.257598 3063.96 3063.96 2791.65 1.00
AIRLOOP F9 N1 DXAC HEAT PUMP 0.195323 0.195323 0.195323 0.195323 2375.11 2375.11 1889.52 1.00
AIRLOOP F9 N2 DXAC HEAT PUMP 0.193734 0.193734 0.193734 0.193734 2355.64 2355.64 1889.52 1.00
AIRLOOP F9 S1 DXAC HEAT PUMP 0.198443 0.198443 0.198443 0.198443 2496.23 2496.23 1885.05 1.00
AIRLOOP F9 S2 DXAC HEAT PUMP 0.199351 0.199351 0.199351 0.199351 2507.13 2507.13 1885.05 1.00
AIRLOOP T SW DXAC HEAT PUMP 0.430106 0.430106 0.430106 0.430106 5241.32 5241.32 3391.52 1.00
AIRLOOP T NW DXAC HEAT PUMP 0.418217 0.418217 0.418217 0.418217 5079.47 5079.47 3402.45 1.00
AIRLOOP T SE DXAC HEAT PUMP 0.366917 0.366917 0.366917 0.366917 4495.28 4495.28 3391.52 1.00
AIRLOOP T NE DXAC HEAT PUMP 0.324820 0.324820 0.324820 0.324820 3904.45 3904.45 3402.45 1.00
AIRLOOP T N1 DXAC HEAT PUMP 0.248549 0.248549 0.248549 0.248549 3104.20 3104.20 2545.49 1.00
AIRLOOP T N2 DXAC HEAT PUMP 0.248245 0.248245 0.248245 0.248245 3100.56 3100.56 2545.49 1.00
AIRLOOP T S1 DXAC HEAT PUMP 0.290618 0.290618 0.290618 0.290618 3617.14 3617.14 2531.48 1.00
AIRLOOP T S2 DXAC HEAT PUMP 0.291477 0.291477 0.291477 0.291477 3623.11 3623.11 2531.48 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
AIRLOOP G SW SUPPLY FAN 0.258910
AIRLOOP G NW SUPPLY FAN 0.255012
AIRLOOP OFFICE SUPPLY FAN 0.327712
AIRLOOP G NE SUPPLY FAN 0.185878
AIRLOOP G N1 SUPPLY FAN 0.132973
AIRLOOP G N2 SUPPLY FAN 0.130982
AIRLOOP G S1 SUPPLY FAN 0.136322
AIRLOOP G S2 SUPPLY FAN 0.142188
AIRLOOP F2 SW SUPPLY FAN 0.333584
AIRLOOP F2 NW SUPPLY FAN 0.326109
AIRLOOP F2 SE SUPPLY FAN 0.289528
AIRLOOP F2 NE SUPPLY FAN 0.247149
AIRLOOP F2 N1 SUPPLY FAN 0.177396
AIRLOOP F2 N2 SUPPLY FAN 0.175768
AIRLOOP F2 S1 SUPPLY FAN 0.183880
AIRLOOP F2 S2 SUPPLY FAN 0.186098
AIRLOOP F3 SW SUPPLY FAN 0.335365
AIRLOOP F3 NW SUPPLY FAN 0.328661
AIRLOOP F3 SE SUPPLY FAN 0.273960
AIRLOOP F3 NE SUPPLY FAN 0.251176
AIRLOOP F3 N1 SUPPLY FAN 0.181470
AIRLOOP F3 N2 SUPPLY FAN 0.179856
AIRLOOP F3 S1 SUPPLY FAN 0.188061
AIRLOOP F3 S2 SUPPLY FAN 0.189196
AIRLOOP F4 SW SUPPLY FAN 0.336964
AIRLOOP F4 NW SUPPLY FAN 0.330385
AIRLOOP F4 SE SUPPLY FAN 0.274280
AIRLOOP F4 NE SUPPLY FAN 0.252823
AIRLOOP F4 N1 SUPPLY FAN 0.183508
AIRLOOP F4 N2 SUPPLY FAN 0.181900
AIRLOOP F4 S1 SUPPLY FAN 0.190023
AIRLOOP F4 S2 SUPPLY FAN 0.190976
AIRLOOP M SW SUPPLY FAN 0.341016
AIRLOOP M NW SUPPLY FAN 0.334616
AIRLOOP M SE SUPPLY FAN 0.278516
AIRLOOP M NE SUPPLY FAN 0.256935
AIRLOOP M N1 SUPPLY FAN 0.187784
AIRLOOP M N2 SUPPLY FAN 0.186181
AIRLOOP M S1 SUPPLY FAN 0.194174
AIRLOOP M S2 SUPPLY FAN 0.195086
AIRLOOP F6 SW SUPPLY FAN 0.337333
AIRLOOP F6 NW SUPPLY FAN 0.330882
AIRLOOP F6 SE SUPPLY FAN 0.275301
AIRLOOP F6 NE SUPPLY FAN 0.253245
AIRLOOP F6 N1 SUPPLY FAN 0.184445
AIRLOOP F6 N2 SUPPLY FAN 0.182854
AIRLOOP F6 S1 SUPPLY FAN 0.190827
AIRLOOP F6 S2 SUPPLY FAN 0.191718
AIRLOOP F7 SW SUPPLY FAN 0.336398
AIRLOOP F7 NW SUPPLY FAN 0.330018
AIRLOOP F7 SE SUPPLY FAN 0.274776
AIRLOOP F7 NE SUPPLY FAN 0.252366
AIRLOOP F7 N1 SUPPLY FAN 0.183802
AIRLOOP F7 N2 SUPPLY FAN 0.182219
AIRLOOP F7 S1 SUPPLY FAN 0.190098
AIRLOOP F7 S2 SUPPLY FAN 0.190972
AIRLOOP F8 SW SUPPLY FAN 0.337093
AIRLOOP F8 NW SUPPLY FAN 0.330781
AIRLOOP F8 SE SUPPLY FAN 0.275720
AIRLOOP F8 NE SUPPLY FAN 0.252998
AIRLOOP F8 N1 SUPPLY FAN 0.184753
AIRLOOP F8 N2 SUPPLY FAN 0.183180
AIRLOOP F8 S1 SUPPLY FAN 0.190874
AIRLOOP F8 S2 SUPPLY FAN 0.191734
AIRLOOP F9 SW SUPPLY FAN 0.349150
AIRLOOP F9 NW SUPPLY FAN 0.342849
AIRLOOP F9 SE SUPPLY FAN 0.284561
AIRLOOP F9 NE SUPPLY FAN 0.257598
AIRLOOP F9 N1 SUPPLY FAN 0.195323
AIRLOOP F9 N2 SUPPLY FAN 0.193734
AIRLOOP F9 S1 SUPPLY FAN 0.198443
AIRLOOP F9 S2 SUPPLY FAN 0.199351
AIRLOOP T SW SUPPLY FAN 0.430106
AIRLOOP T NW SUPPLY FAN 0.418217
AIRLOOP T SE SUPPLY FAN 0.366917
AIRLOOP T NE SUPPLY FAN 0.324820
AIRLOOP T N1 SUPPLY FAN 0.248549
AIRLOOP T N2 SUPPLY FAN 0.248245
AIRLOOP T S1 SUPPLY FAN 0.290618
AIRLOOP T S2 SUPPLY FAN 0.291477


COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Heating Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP HEATING MODE AIRLOOP G SW 0.258910 3205.74 0.000070
HEAT PUMP HEATING MODE AIRLOOP G NW 0.255012 3148.90 0.000069
HEAT PUMP HEATING MODE AIRLOOP OFFICE 0.327712 4016.33 0.000088
HEAT PUMP HEATING MODE AIRLOOP G NE 0.185878 2247.30 0.000049
HEAT PUMP HEATING MODE AIRLOOP G N1 0.132973 1649.01 0.000036
HEAT PUMP HEATING MODE AIRLOOP G N2 0.130982 1624.43 0.000035
HEAT PUMP HEATING MODE AIRLOOP G S1 0.136322 1773.44 0.000039
HEAT PUMP HEATING MODE AIRLOOP G S2 0.142188 1845.11 0.000040
HEAT PUMP HEATING MODE AIRLOOP F2 SW 0.333584 4097.56 0.000090
HEAT PUMP HEATING MODE AIRLOOP F2 NW 0.326109 3998.19 0.000087
HEAT PUMP HEATING MODE AIRLOOP F2 SE 0.289528 3602.22 0.000079
HEAT PUMP HEATING MODE AIRLOOP F2 NE 0.247149 2973.18 0.000065
HEAT PUMP HEATING MODE AIRLOOP F2 N1 0.177396 2184.74 0.000048
HEAT PUMP HEATING MODE AIRLOOP F2 N2 0.175768 2164.71 0.000047
HEAT PUMP HEATING MODE AIRLOOP F2 S1 0.183880 2347.31 0.000051
HEAT PUMP HEATING MODE AIRLOOP F2 S2 0.186098 2369.96 0.000052
HEAT PUMP HEATING MODE AIRLOOP F3 SW 0.335365 4106.84 0.000090
HEAT PUMP HEATING MODE AIRLOOP F3 NW 0.328661 4016.93 0.000088
HEAT PUMP HEATING MODE AIRLOOP F3 SE 0.273960 3400.35 0.000074
HEAT PUMP HEATING MODE AIRLOOP F3 NE 0.251176 3010.14 0.000066
HEAT PUMP HEATING MODE AIRLOOP F3 N1 0.181470 2227.65 0.000049
HEAT PUMP HEATING MODE AIRLOOP F3 N2 0.179856 2207.81 0.000048
HEAT PUMP HEATING MODE AIRLOOP F3 S1 0.188061 2391.41 0.000052
HEAT PUMP HEATING MODE AIRLOOP F3 S2 0.189196 2400.81 0.000052
HEAT PUMP HEATING MODE AIRLOOP F4 SW 0.336964 4117.02 0.000090
HEAT PUMP HEATING MODE AIRLOOP F4 NW 0.330385 4028.65 0.000088
HEAT PUMP HEATING MODE AIRLOOP F4 SE 0.274280 3395.33 0.000074
HEAT PUMP HEATING MODE AIRLOOP F4 NE 0.252823 3034.38 0.000066
HEAT PUMP HEATING MODE AIRLOOP F4 N1 0.183508 2247.30 0.000049
HEAT PUMP HEATING MODE AIRLOOP F4 N2 0.181900 2227.55 0.000049
HEAT PUMP HEATING MODE AIRLOOP F4 S1 0.190023 2410.14 0.000053
HEAT PUMP HEATING MODE AIRLOOP F4 S2 0.190976 2417.30 0.000053
HEAT PUMP HEATING MODE AIRLOOP M SW 0.341016 4158.84 0.000091
HEAT PUMP HEATING MODE AIRLOOP M NW 0.334616 4072.71 0.000089
HEAT PUMP HEATING MODE AIRLOOP M SE 0.278516 3439.66 0.000075
HEAT PUMP HEATING MODE AIRLOOP M NE 0.256935 3077.10 0.000067
HEAT PUMP HEATING MODE AIRLOOP M N1 0.187784 2295.42 0.000050
HEAT PUMP HEATING MODE AIRLOOP M N2 0.186181 2275.75 0.000050
HEAT PUMP HEATING MODE AIRLOOP M S1 0.194174 2456.49 0.000054
HEAT PUMP HEATING MODE AIRLOOP M S2 0.195086 2463.12 0.000054
HEAT PUMP HEATING MODE AIRLOOP F6 SW 0.337333 4107.38 0.000090
HEAT PUMP HEATING MODE AIRLOOP F6 NW 0.330882 4020.59 0.000088
HEAT PUMP HEATING MODE AIRLOOP F6 SE 0.275301 3398.79 0.000074
HEAT PUMP HEATING MODE AIRLOOP F6 NE 0.253245 3025.97 0.000066
HEAT PUMP HEATING MODE AIRLOOP F6 N1 0.184445 2250.64 0.000049
HEAT PUMP HEATING MODE AIRLOOP F6 N2 0.182854 2231.12 0.000049
HEAT PUMP HEATING MODE AIRLOOP F6 S1 0.190827 2412.06 0.000053
HEAT PUMP HEATING MODE AIRLOOP F6 S2 0.191718 2418.41 0.000053
HEAT PUMP HEATING MODE AIRLOOP F7 SW 0.336398 4090.25 0.000089
HEAT PUMP HEATING MODE AIRLOOP F7 NW 0.330018 4004.31 0.000087
HEAT PUMP HEATING MODE AIRLOOP F7 SE 0.274776 3386.97 0.000074
HEAT PUMP HEATING MODE AIRLOOP F7 NE 0.252366 3009.82 0.000066
HEAT PUMP HEATING MODE AIRLOOP F7 N1 0.183802 2239.43 0.000049
HEAT PUMP HEATING MODE AIRLOOP F7 N2 0.182219 2220.02 0.000048
HEAT PUMP HEATING MODE AIRLOOP F7 S1 0.190098 2399.99 0.000052
HEAT PUMP HEATING MODE AIRLOOP F7 S2 0.190972 2406.11 0.000053
HEAT PUMP HEATING MODE AIRLOOP F8 SW 0.337093 4093.59 0.000089
HEAT PUMP HEATING MODE AIRLOOP F8 NW 0.330781 4008.49 0.000088
HEAT PUMP HEATING MODE AIRLOOP F8 SE 0.275720 3393.58 0.000074
HEAT PUMP HEATING MODE AIRLOOP F8 NE 0.252998 3012.60 0.000066
HEAT PUMP HEATING MODE AIRLOOP F8 N1 0.184753 2248.14 0.000049
HEAT PUMP HEATING MODE AIRLOOP F8 N2 0.183180 2228.86 0.000049
HEAT PUMP HEATING MODE AIRLOOP F8 S1 0.190874 2406.58 0.000053
HEAT PUMP HEATING MODE AIRLOOP F8 S2 0.191734 2412.52 0.000053
HEAT PUMP HEATING MODE AIRLOOP F9 SW 0.349150 4235.91 0.000093
HEAT PUMP HEATING MODE AIRLOOP F9 NW 0.342849 4151.08 0.000091
HEAT PUMP HEATING MODE AIRLOOP F9 SE 0.284561 3496.63 0.000076
HEAT PUMP HEATING MODE AIRLOOP F9 NE 0.257598 3063.96 0.000067
HEAT PUMP HEATING MODE AIRLOOP F9 N1 0.195323 2375.11 0.000052
HEAT PUMP HEATING MODE AIRLOOP F9 N2 0.193734 2355.64 0.000051
HEAT PUMP HEATING MODE AIRLOOP F9 S1 0.198443 2496.23 0.000055
HEAT PUMP HEATING MODE AIRLOOP F9 S2 0.199351 2507.13 0.000055
HEAT PUMP HEATING MODE AIRLOOP T SW 0.430106 5241.32 0.000114
HEAT PUMP HEATING MODE AIRLOOP T NW 0.418217 5079.47 0.000111
HEAT PUMP HEATING MODE AIRLOOP T SE 0.366917 4495.28 0.000098
HEAT PUMP HEATING MODE AIRLOOP T NE 0.324820 3904.45 0.000085
HEAT PUMP HEATING MODE AIRLOOP T N1 0.248549 3104.20 0.000068
HEAT PUMP HEATING MODE AIRLOOP T N2 0.248245 3100.56 0.000068
HEAT PUMP HEATING MODE AIRLOOP T S1 0.290618 3617.14 0.000079
HEAT PUMP HEATING MODE AIRLOOP T S2 0.291477 3623.11 0.000079


Coil:Heating:Electric

Nominal Capacity [W]
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW 2438.18
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW 2437.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE 3204.67
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE 2437.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 1803.85
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 1803.85
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 1801.10
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 1809.61
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW 2417.40
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW 2415.07
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE 2442.87
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE 2415.07
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 1636.45
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 1636.45
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 1641.48
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 1643.18
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW 2408.10
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW 2408.73
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE 2410.95
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE 2408.73
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 1603.57
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 1603.57
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 1603.68
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 1603.96
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW 2437.51
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW 2440.24
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE 2437.81
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE 2440.24
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 1613.44
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 1613.44
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 1611.18
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 1611.22
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW 2444.07
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW 2447.13
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE 2444.10
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE 2447.13
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 1605.70
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 1605.70
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 1603.05
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 1603.05
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW 2518.98
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW 2524.13
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE 2518.98
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE 2524.13
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 1664.53
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 1664.53
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 1659.73
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 1659.73
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW 2566.03
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW 2571.88
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE 2566.03
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE 2571.88
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 1699.07
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 1699.07
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 1693.52
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 1693.52
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW 2617.09
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW 2623.31
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE 2617.09
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE 2623.31
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 1739.23
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 1739.23
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 1733.27
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 1733.27
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW 2787.45
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW 2791.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE 2787.45
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE 2791.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 1889.52
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 1889.52
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 1885.05
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 1885.05
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW 3391.52
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW 3402.45
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE 3391.52
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE 3402.45
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 2545.49
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 2545.49
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 2531.48
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 2531.48


PlantLoop

Maximum Loop Flow Rate [m3/s] Plant Loop Volume [m3]
SHWSYS1 0.000289 0.325214
SINGLE WATER PLANT LOOP 0.005317 5.98


Boiler:HotWater

Design Water Flow Rate [m3/s]
CENTRAL BOILER 0.005317


WaterHeater:Mixed

Use Side Design Flow Rate [m3/s]
SHWSYS1 WATER HEATER 0.000289


EvaporativeFluidCooler:SingleSpeed

Design Water Flow Rate [m3/s] Fan Power at Design Air Flow Rate [W] Design Air Flow Rate [m3/s] U-Factor Times Area Value at Design Air Flow Rate [W/C]
CENTRAL TOWER 0.005317 2566.74 8.21 6542.85


Pump:ConstantSpeed

Rated Flow Rate [m3/s] Rated Power Consumption [W]
SHWSYS1 PUMP 0.000289 36.93
PLANT CIRC PUMP 0.005317 1356.10



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW3 |
G WWALL SWA GWINDOW2 |
G NWALL NWA GWINDOW4 |
G WWALL NWA GWINDOW6 |
G SWALL SEA GWINDOW1 |
G EWALL SEA GWINDOW8 |
G NWALL NEA GWINDOW5 |
G EWALL NEA GWINDOW7 |
G NWALL N1A GWINDOW9 |
G NWALL N2A GWINDOW10 |
G SWALL S1A GWINDOW11 |
G SWALL S2A GWINDOW12 |
G WWALL C GWINDOW13 |
G EWALL C ENTRANCE DOOR |
F2 WWALL SWA F2WINDOW2 |
F2 SWALL SWA F2WINDOW3 |
F2 NWALL NWA F2WINDOW4 |
F2 WWALL NWA F2WINDOW6 |
F2 EWALL SEA F2WINDOW8 |
F2 SWALL SEA F2WINDOW1 |
F2 NWALL NEA F2WINDOW5 |
F2 EWALL NEA F2WINDOW7 |
F2 NWALL N1A F2WINDOW9 |
F2 NWALL N2A F2WINDOW10 |
F2 SWALL S1A F2WINDOW11 |
F2 SWALL S2A F2WINDOW12 |
F2 WWALL C F2WINDOW13 |
F2 EWALL C F2WINDOW14 |
F3 WWALL SWA F3WINDOW2 |
F3 SWALL SWA F3WINDOW3 |
F3 NWALL NWA F3WINDOW4 |
F3 WWALL NWA F3WINDOW6 |
F3 EWALL SEA F3WINDOW8 |
F3 SWALL SEA F3WINDOW1 |
F3 NWALL NEA F3WINDOW5 |
F3 EWALL NEA F3WINDOW7 |
F3 NWALL N1A F3WINDOW9 |
F3 NWALL N2A F3WINDOW10 |
F3 SWALL S1A F3WINDOW11 |
F3 SWALL S2A F3WINDOW12 |
F3 WWALL C F3WINDOW13 |
F3 EWALL C F3WINDOW14 |
F4 WWALL SWA F4WINDOW2 |
F4 SWALL SWA F4WINDOW3 |
F4 NWALL NWA F4WINDOW4 |
F4 WWALL NWA F4WINDOW6 |
F4 EWALL SEA F4WINDOW8 |
F4 SWALL SEA F4WINDOW1 |
F4 NWALL NEA F4WINDOW5 |
F4 EWALL NEA F4WINDOW7 |
F4 NWALL N1A F4WINDOW9 |
F4 NWALL N2A F4WINDOW10 |
F4 SWALL S1A F4WINDOW11 |
F4 SWALL S2A F4WINDOW12 |
F4 WWALL C F4WINDOW13 |
F4 EWALL C F4WINDOW14 |
M WWALL SWA MWINDOW2 |
M SWALL SWA MWINDOW3 |
M NWALL NWA MWINDOW4 |
M WWALL NWA MWINDOW6 |
M EWALL SEA MWINDOW8 |
M SWALL SEA MWINDOW1 |
M NWALL NEA MWINDOW5 |
M EWALL NEA MWINDOW7 |
M NWALL N1A MWINDOW9 |
M NWALL N2A MWINDOW10 |
M SWALL S1A MWINDOW11 |
M SWALL S2A MWINDOW12 |
M WWALL C MWINDOW13 |
M EWALL C MWINDOW14 |
F6 WWALL SWA F6WINDOW2 |
F6 SWALL SWA F6WINDOW3 |
F6 NWALL NWA F6WINDOW4 |
F6 WWALL NWA F6WINDOW6 |
F6 EWALL SEA F6WINDOW8 |
F6 SWALL SEA F6WINDOW1 |
F6 NWALL NEA F6WINDOW5 |
F6 EWALL NEA F6WINDOW7 |
F6 NWALL N1A F6WINDOW9 |
F6 NWALL N2A F6WINDOW10 |
F6 SWALL S1A F6WINDOW11 |
F6 SWALL S2A F6WINDOW12 |
F6 WWALL C F6WINDOW13 |
F6 EWALL C F6WINDOW14 |
F7 WWALL SWA F7WINDOW2 |
F7 SWALL SWA F7WINDOW3 |
F7 NWALL NWA F7WINDOW4 |
F7 WWALL NWA F7WINDOW6 |
F7 EWALL SEA F7WINDOW8 |
F7 SWALL SEA F7WINDOW1 |
F7 NWALL NEA F7WINDOW5 |
F7 EWALL NEA F7WINDOW7 |
F7 NWALL N1A F7WINDOW9 |
F7 NWALL N2A F7WINDOW10 |
F7 SWALL S1A F7WINDOW11 |
F7 SWALL S2A F7WINDOW12 |
F7 WWALL C F7WINDOW13 |
F7 EWALL C F7WINDOW14 |
F8 WWALL SWA F8WINDOW2 |
F8 SWALL SWA F8WINDOW3 |
F8 NWALL NWA F8WINDOW4 |
F8 WWALL NWA F8WINDOW6 |
F8 EWALL SEA F8WINDOW8 |
F8 SWALL SEA F8WINDOW1 |
F8 NWALL NEA F8WINDOW5 |
F8 EWALL NEA F8WINDOW7 |
F8 NWALL N1A F8WINDOW9 |
F8 NWALL N2A F8WINDOW10 |
F8 SWALL S1A F8WINDOW11 |
F8 SWALL S2A F8WINDOW12 |
F8 WWALL C F8WINDOW13 |
F8 EWALL C F8WINDOW14 |
F9 WWALL SWA F9WINDOW2 |
F9 SWALL SWA F9WINDOW3 |
F9 NWALL NWA F9WINDOW4 |
F9 WWALL NWA F9WINDOW6 |
F9 EWALL SEA F9WINDOW8 |
F9 SWALL SEA F9WINDOW1 |
F9 NWALL NEA F9WINDOW5 |
F9 EWALL NEA F9WINDOW7 |
F9 NWALL N1A F9WINDOW9 |
F9 NWALL N2A F9WINDOW10 |
F9 SWALL S1A F9WINDOW11 |
F9 SWALL S2A F9WINDOW12 |
F9 WWALL C F9WINDOW13 |
F9 EWALL C F9WINDOW14 |
T WWALL SWA TWINDOW2 |
T SWALL SWA TWINDOW3 |
T NWALL NWA TWINDOW4 |
T WWALL NWA TWINDOW6 |
T EWALL SEA TWINDOW8 |
T SWALL SEA TWINDOW1 |
T NWALL NEA TWINDOW5 |
T EWALL NEA TWINDOW7 |
T NWALL N1A TWINDOW9 |
T NWALL N2A TWINDOW10 |
T SWALL S1A TWINDOW11 |
T SWALL S2A TWINDOW12 |
T WWALL C TWINDOW13 |
T EWALL C TWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.61 2.60
February 22.78 4.29
March 22.98 8.77
April 23.64 13.91
May 23.86 17.82
June 24.30 23.21
July 24.40 25.63
August 24.37 24.08
September 24.33 20.49
October 23.84 13.71
November 23.19 6.96
December 22.67 2.07
     
Annual Sum or Average 23.58 13.68
Minimum of Months 22.61 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.83 2.60
February 22.00 4.29
March 22.33 8.77
April 23.34 13.91
May 23.83 17.82
June 24.32 23.21
July 24.40 25.63
August 24.36 24.08
September 24.30 20.49
October 23.31 13.71
November 22.21 6.96
December 21.78 2.07
     
Annual Sum or Average 23.17 13.68
Minimum of Months 21.78 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.56 2.60
February 22.73 4.29
March 23.04 8.77
April 23.68 13.91
May 24.03 17.82
June 24.36 23.21
July 24.40 25.63
August 24.40 24.08
September 24.41 20.49
October 23.80 13.71
November 23.03 6.96
December 22.61 2.07
     
Annual Sum or Average 23.59 13.68
Minimum of Months 22.56 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.74 2.60
February 21.88 4.29
March 22.25 8.77
April 23.35 13.91
May 23.83 17.82
June 24.32 23.21
July 24.42 25.63
August 24.37 24.08
September 24.31 20.49
October 23.24 13.71
November 22.05 6.96
December 21.71 2.07
     
Annual Sum or Average 23.13 13.68
Minimum of Months 21.71 2.07
Maximum of Months 24.42 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 2.60
February 21.82 4.29
March 22.05 8.77
April 22.99 13.91
May 23.62 17.82
June 24.29 23.21
July 24.41 25.63
August 24.35 24.08
September 24.26 20.49
October 23.06 13.71
November 21.99 6.96
December 21.71 2.07
     
Annual Sum or Average 23.03 13.68
Minimum of Months 21.71 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.72 2.60
February 21.81 4.29
March 22.05 8.77
April 23.00 13.91
May 23.62 17.82
June 24.29 23.21
July 24.41 25.63
August 24.35 24.08
September 24.26 20.49
October 23.05 13.71
November 21.98 6.96
December 21.71 2.07
     
Annual Sum or Average 23.03 13.68
Minimum of Months 21.71 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.67 2.60
February 22.82 4.29
March 22.95 8.77
April 23.48 13.91
May 23.72 17.82
June 24.27 23.21
July 24.40 25.63
August 24.40 24.08
September 24.40 20.49
October 23.86 13.71
November 23.29 6.96
December 22.77 2.07
     
Annual Sum or Average 23.59 13.68
Minimum of Months 22.67 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.69 2.60
February 22.84 4.29
March 22.99 8.77
April 23.52 13.91
May 23.75 17.82
June 24.28 23.21
July 24.39 25.63
August 24.39 24.08
September 24.40 20.49
October 23.87 13.71
November 23.30 6.96
December 22.79 2.07
     
Annual Sum or Average 23.60 13.68
Minimum of Months 22.69 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 18.74 2.60
February 19.29 4.29
March 20.56 8.77
April 22.20 13.91
May 23.33 17.82
June 25.64 23.21
July 26.32 25.63
August 25.94 24.08
September 25.00 20.49
October 22.36 13.71
November 20.13 6.96
December 18.62 2.07
     
Annual Sum or Average 22.36 13.68
Minimum of Months 18.62 2.07
Maximum of Months 26.32 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.23 2.60
February 23.42 4.29
March 23.82 8.77
April 24.24 13.91
May 24.27 17.82
June 24.37 23.21
July 24.40 25.63
August 24.39 24.08
September 24.38 20.49
October 24.22 13.71
November 23.89 6.96
December 23.29 2.07
     
Annual Sum or Average 24.00 13.68
Minimum of Months 23.23 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.99 2.60
February 22.30 4.29
March 23.03 8.77
April 24.07 13.91
May 24.24 17.82
June 24.38 23.21
July 24.41 25.63
August 24.39 24.08
September 24.35 20.49
October 23.87 13.71
November 22.79 6.96
December 21.92 2.07
     
Annual Sum or Average 23.48 13.68
Minimum of Months 21.92 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.21 2.60
February 23.41 4.29
March 23.84 8.77
April 24.25 13.91
May 24.31 17.82
June 24.38 23.21
July 24.40 25.63
August 24.40 24.08
September 24.40 20.49
October 24.22 13.71
November 23.87 6.96
December 23.29 2.07
     
Annual Sum or Average 24.00 13.68
Minimum of Months 23.21 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.88 2.60
February 22.15 4.29
March 22.93 8.77
April 24.06 13.91
May 24.26 17.82
June 24.39 23.21
July 24.43 25.63
August 24.39 24.08
September 24.36 20.49
October 23.79 13.71
November 22.58 6.96
December 21.79 2.07
     
Annual Sum or Average 23.42 13.68
Minimum of Months 21.79 2.07
Maximum of Months 24.43 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.88 2.60
February 22.10 4.29
March 22.77 8.77
April 23.90 13.91
May 24.18 17.82
June 24.37 23.21
July 24.41 25.63
August 24.38 24.08
September 24.33 20.49
October 23.73 13.71
November 22.60 6.96
December 21.81 2.07
     
Annual Sum or Average 23.38 13.68
Minimum of Months 21.81 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.87 2.60
February 22.09 4.29
March 22.76 8.77
April 23.90 13.91
May 24.18 17.82
June 24.37 23.21
July 24.41 25.63
August 24.38 24.08
September 24.33 20.49
October 23.72 13.71
November 22.58 6.96
December 21.80 2.07
     
Annual Sum or Average 23.37 13.68
Minimum of Months 21.80 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.47 2.60
February 23.62 4.29
March 23.91 8.77
April 24.21 13.91
May 24.22 17.82
June 24.35 23.21
July 24.40 25.63
August 24.43 24.08
September 24.46 20.49
October 24.30 13.71
November 24.04 6.96
December 23.56 2.07
     
Annual Sum or Average 24.08 13.68
Minimum of Months 23.47 2.07
Maximum of Months 24.46 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.47 2.60
February 23.62 4.29
March 23.92 8.77
April 24.22 13.91
May 24.23 17.82
June 24.35 23.21
July 24.40 25.63
August 24.42 24.08
September 24.46 20.49
October 24.30 13.71
November 24.04 6.96
December 23.57 2.07
     
Annual Sum or Average 24.09 13.68
Minimum of Months 23.47 2.07
Maximum of Months 24.46 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 CORRIDOR

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.23 2.60
February 23.55 4.29
March 24.31 8.77
April 25.43 13.91
May 25.79 17.82
June 26.52 23.21
July 26.76 25.63
August 26.69 24.08
September 26.40 20.49
October 25.41 13.71
November 24.21 6.96
December 23.21 2.07
     
Annual Sum or Average 25.13 13.68
Minimum of Months 23.21 2.07
Maximum of Months 26.76 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.37 2.60
February 23.54 4.29
March 23.95 8.77
April 24.29 13.91
May 24.29 17.82
June 24.37 23.21
July 24.41 25.63
August 24.39 24.08
September 24.38 20.49
October 24.26 13.71
November 24.00 6.96
December 23.43 2.07
     
Annual Sum or Average 24.06 13.68
Minimum of Months 23.37 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.05 2.60
February 22.40 4.29
March 23.23 8.77
April 24.17 13.91
May 24.27 17.82
June 24.38 23.21
July 24.41 25.63
August 24.39 24.08
September 24.35 20.49
October 23.96 13.71
November 22.99 6.96
December 21.97 2.07
     
Annual Sum or Average 23.55 13.68
Minimum of Months 21.97 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.29 2.60
February 23.47 4.29
March 23.91 8.77
April 24.27 13.91
May 24.32 17.82
June 24.38 23.21
July 24.40 25.63
August 24.41 24.08
September 24.41 20.49
October 24.25 13.71
November 23.93 6.96
December 23.37 2.07
     
Annual Sum or Average 24.04 13.68
Minimum of Months 23.29 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.94 2.60
February 22.24 4.29
March 23.13 8.77
April 24.15 13.91
May 24.29 17.82
June 24.40 23.21
July 24.43 25.63
August 24.39 24.08
September 24.36 20.49
October 23.90 13.71
November 22.78 6.96
December 21.82 2.07
     
Annual Sum or Average 23.49 13.68
Minimum of Months 21.82 2.07
Maximum of Months 24.43 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.96 2.60
February 22.24 4.29
March 23.08 8.77
April 24.08 13.91
May 24.24 17.82
June 24.37 23.21
July 24.41 25.63
August 24.38 24.08
September 24.33 20.49
October 23.89 13.71
November 22.90 6.96
December 21.88 2.07
     
Annual Sum or Average 23.49 13.68
Minimum of Months 21.88 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.95 2.60
February 22.23 4.29
March 23.07 8.77
April 24.08 13.91
May 24.24 17.82
June 24.38 23.21
July 24.42 25.63
August 24.38 24.08
September 24.33 20.49
October 23.88 13.71
November 22.87 6.96
December 21.87 2.07
     
Annual Sum or Average 23.48 13.68
Minimum of Months 21.87 2.07
Maximum of Months 24.42 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.66 2.60
February 23.81 4.29
March 24.09 8.77
April 24.29 13.91
May 24.27 17.82
June 24.35 23.21
July 24.41 25.63
August 24.42 24.08
September 24.46 20.49
October 24.36 13.71
November 24.17 6.96
December 23.77 2.07
     
Annual Sum or Average 24.17 13.68
Minimum of Months 23.66 2.07
Maximum of Months 24.46 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.65 2.60
February 23.81 4.29
March 24.09 8.77
April 24.29 13.91
May 24.27 17.82
June 24.35 23.21
July 24.40 25.63
August 24.42 24.08
September 24.46 20.49
October 24.36 13.71
November 24.17 6.96
December 23.76 2.07
     
Annual Sum or Average 24.17 13.68
Minimum of Months 23.65 2.07
Maximum of Months 24.46 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 CORRIDOR

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.75 2.60
February 24.07 4.29
March 24.86 8.77
April 25.90 13.91
May 26.15 17.82
June 26.66 23.21
July 26.84 25.63
August 26.79 24.08
September 26.54 20.49
October 25.83 13.71
November 24.76 6.96
December 23.73 2.07
     
Annual Sum or Average 25.50 13.68
Minimum of Months 23.73 2.07
Maximum of Months 26.84 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.38 2.60
February 23.55 4.29
March 23.96 8.77
April 24.29 13.91
May 24.29 17.82
June 24.37 23.21
July 24.41 25.63
August 24.39 24.08
September 24.38 20.49
October 24.26 13.71
November 24.00 6.96
December 23.44 2.07
     
Annual Sum or Average 24.06 13.68
Minimum of Months 23.38 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.07 2.60
February 22.42 4.29
March 23.26 8.77
April 24.18 13.91
May 24.27 17.82
June 24.38 23.21
July 24.41 25.63
August 24.39 24.08
September 24.36 20.49
October 23.98 13.71
November 23.05 6.96
December 21.98 2.07
     
Annual Sum or Average 23.57 13.68
Minimum of Months 21.98 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.29 2.60
February 23.46 4.29
March 23.91 8.77
April 24.28 13.91
May 24.31 17.82
June 24.38 23.21
July 24.40 25.63
August 24.41 24.08
September 24.41 20.49
October 24.25 13.71
November 23.94 6.96
December 23.37 2.07
     
Annual Sum or Average 24.04 13.68
Minimum of Months 23.29 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.95 2.60
February 22.26 4.29
March 23.17 8.77
April 24.16 13.91
May 24.29 17.82
June 24.41 23.21
July 24.43 25.63
August 24.39 24.08
September 24.36 20.49
October 23.92 13.71
November 22.85 6.96
December 21.83 2.07
     
Annual Sum or Average 23.51 13.68
Minimum of Months 21.83 2.07
Maximum of Months 24.43 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.99 2.60
February 22.30 4.29
March 23.18 8.77
April 24.12 13.91
May 24.25 17.82
June 24.38 23.21
July 24.42 25.63
August 24.38 24.08
September 24.33 20.49
October 23.94 13.71
November 23.03 6.96
December 21.90 2.07
     
Annual Sum or Average 23.52 13.68
Minimum of Months 21.90 2.07
Maximum of Months 24.42 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.99 2.60
February 22.28 4.29
March 23.17 8.77
April 24.12 13.91
May 24.25 17.82
June 24.38 23.21
July 24.42 25.63
August 24.38 24.08
September 24.33 20.49
October 23.93 13.71
November 23.00 6.96
December 21.89 2.07
     
Annual Sum or Average 23.52 13.68
Minimum of Months 21.89 2.07
Maximum of Months 24.42 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.69 2.60
February 23.84 4.29
March 24.11 8.77
April 24.30 13.91
May 24.28 17.82
June 24.35 23.21
July 24.41 25.63
August 24.43 24.08
September 24.46 20.49
October 24.37 13.71
November 24.20 6.96
December 23.81 2.07
     
Annual Sum or Average 24.19 13.68
Minimum of Months 23.69 2.07
Maximum of Months 24.46 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.69 2.60
February 23.83 4.29
March 24.11 8.77
April 24.30 13.91
May 24.28 17.82
June 24.36 23.21
July 24.41 25.63
August 24.43 24.08
September 24.46 20.49
October 24.37 13.71
November 24.20 6.96
December 23.80 2.07
     
Annual Sum or Average 24.19 13.68
Minimum of Months 23.69 2.07
Maximum of Months 24.46 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 CORRIDOR

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.93 2.60
February 24.25 4.29
March 25.05 8.77
April 26.07 13.91
May 26.29 17.82
June 26.76 23.21
July 26.93 25.63
August 26.88 24.08
September 26.64 20.49
October 25.99 13.71
November 24.96 6.96
December 23.91 2.07
     
Annual Sum or Average 25.64 13.68
Minimum of Months 23.91 2.07
Maximum of Months 26.93 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.38 2.60
February 23.54 4.29
March 23.95 8.77
April 24.29 13.91
May 24.29 17.82
June 24.37 23.21
July 24.41 25.63
August 24.39 24.08
September 24.38 20.49
October 24.26 13.71
November 24.00 6.96
December 23.45 2.07
     
Annual Sum or Average 24.06 13.68
Minimum of Months 23.38 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.09 2.60
February 22.43 4.29
March 23.26 8.77
April 24.18 13.91
May 24.27 17.82
June 24.38 23.21
July 24.41 25.63
August 24.39 24.08
September 24.35 20.49
October 23.99 13.71
November 23.07 6.96
December 22.00 2.07
     
Annual Sum or Average 23.57 13.68
Minimum of Months 22.00 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.30 2.60
February 23.46 4.29
March 23.89 8.77
April 24.27 13.91
May 24.31 17.82
June 24.38 23.21
July 24.40 25.63
August 24.41 24.08
September 24.41 20.49
October 24.25 13.71
November 23.94 6.96
December 23.38 2.07
     
Annual Sum or Average 24.03 13.68
Minimum of Months 23.30 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.97 2.60
February 22.27 4.29
March 23.17 8.77
April 24.16 13.91
May 24.29 17.82
June 24.41 23.21
July 24.43 25.63
August 24.39 24.08
September 24.36 20.49
October 23.93 13.71
November 22.87 6.96
December 21.84 2.07
     
Annual Sum or Average 23.51 13.68
Minimum of Months 21.84 2.07
Maximum of Months 24.43 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.02 2.60
February 22.33 4.29
March 23.21 8.77
April 24.13 13.91
May 24.25 17.82
June 24.38 23.21
July 24.42 25.63
August 24.38 24.08
September 24.33 20.49
October 23.96 13.71
November 23.09 6.96
December 21.93 2.07
     
Annual Sum or Average 23.54 13.68
Minimum of Months 21.93 2.07
Maximum of Months 24.42 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.02 2.60
February 22.31 4.29
March 23.20 8.77
April 24.13 13.91
May 24.25 17.82
June 24.38 23.21
July 24.42 25.63
August 24.38 24.08
September 24.33 20.49
October 23.96 13.71
November 23.07 6.96
December 21.92 2.07
     
Annual Sum or Average 23.54 13.68
Minimum of Months 21.92 2.07
Maximum of Months 24.42 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.71 2.60
February 23.85 4.29
March 24.12 8.77
April 24.30 13.91
May 24.28 17.82
June 24.35 23.21
July 24.41 25.63
August 24.42 24.08
September 24.46 20.49
October 24.37 13.71
November 24.21 6.96
December 23.83 2.07
     
Annual Sum or Average 24.19 13.68
Minimum of Months 23.71 2.07
Maximum of Months 24.46 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.70 2.60
February 23.84 4.29
March 24.12 8.77
April 24.30 13.91
May 24.28 17.82
June 24.35 23.21
July 24.41 25.63
August 24.42 24.08
September 24.46 20.49
October 24.37 13.71
November 24.20 6.96
December 23.82 2.07
     
Annual Sum or Average 24.19 13.68
Minimum of Months 23.70 2.07
Maximum of Months 24.46 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.57 2.60
February 24.88 4.29
March 25.68 8.77
April 26.68 13.91
May 26.89 17.82
June 27.35 23.21
July 27.53 25.63
August 27.48 24.08
September 27.24 20.49
October 26.61 13.71
November 25.61 6.96
December 24.55 2.07
     
Annual Sum or Average 26.26 13.68
Minimum of Months 24.55 2.07
Maximum of Months 27.53 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.31 2.60
February 23.46 4.29
March 23.87 8.77
April 24.26 13.91
May 24.26 17.82
June 24.36 23.21
July 24.41 25.63
August 24.39 24.08
September 24.37 20.49
October 24.24 13.71
November 23.95 6.96
December 23.38 2.07
     
Annual Sum or Average 24.02 13.68
Minimum of Months 23.31 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.03 2.60
February 22.35 4.29
March 23.11 8.77
April 24.12 13.91
May 24.23 17.82
June 24.38 23.21
July 24.41 25.63
August 24.38 24.08
September 24.35 20.49
October 23.94 13.71
November 22.95 6.96
December 21.95 2.07
     
Annual Sum or Average 23.52 13.68
Minimum of Months 21.95 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.22 2.60
February 23.38 4.29
March 23.81 8.77
April 24.24 13.91
May 24.28 17.82
June 24.37 23.21
July 24.40 25.63
August 24.41 24.08
September 24.40 20.49
October 24.22 13.71
November 23.88 6.96
December 23.31 2.07
     
Annual Sum or Average 24.00 13.68
Minimum of Months 23.22 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.92 2.60
February 22.21 4.29
March 23.02 8.77
April 24.11 13.91
May 24.26 17.82
June 24.40 23.21
July 24.43 25.63
August 24.39 24.08
September 24.35 20.49
October 23.87 13.71
November 22.76 6.96
December 21.81 2.07
     
Annual Sum or Average 23.47 13.68
Minimum of Months 21.81 2.07
Maximum of Months 24.43 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.97 2.60
February 22.25 4.29
March 23.05 8.77
April 24.07 13.91
May 24.22 17.82
June 24.37 23.21
July 24.42 25.63
August 24.38 24.08
September 24.32 20.49
October 23.90 13.71
November 22.96 6.96
December 21.88 2.07
     
Annual Sum or Average 23.49 13.68
Minimum of Months 21.88 2.07
Maximum of Months 24.42 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.96 2.60
February 22.23 4.29
March 23.04 8.77
April 24.07 13.91
May 24.22 17.82
June 24.37 23.21
July 24.42 25.63
August 24.38 24.08
September 24.32 20.49
October 23.90 13.71
November 22.93 6.96
December 21.87 2.07
     
Annual Sum or Average 23.48 13.68
Minimum of Months 21.87 2.07
Maximum of Months 24.42 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.65 2.60
February 23.78 4.29
March 24.05 8.77
April 24.26 13.91
May 24.25 17.82
June 24.35 23.21
July 24.41 25.63
August 24.42 24.08
September 24.45 20.49
October 24.35 13.71
November 24.16 6.96
December 23.76 2.07
     
Annual Sum or Average 24.16 13.68
Minimum of Months 23.65 2.07
Maximum of Months 24.45 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.64 2.60
February 23.77 4.29
March 24.05 8.77
April 24.27 13.91
May 24.25 17.82
June 24.35 23.21
July 24.41 25.63
August 24.42 24.08
September 24.45 20.49
October 24.35 13.71
November 24.16 6.96
December 23.76 2.07
     
Annual Sum or Average 24.16 13.68
Minimum of Months 23.64 2.07
Maximum of Months 24.45 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 CORRIDOR

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.88 2.60
February 24.18 4.29
March 24.95 8.77
April 26.02 13.91
May 26.25 17.82
June 26.74 23.21
July 26.92 25.63
August 26.87 24.08
September 26.62 20.49
October 25.96 13.71
November 24.91 6.96
December 23.87 2.07
     
Annual Sum or Average 25.60 13.68
Minimum of Months 23.87 2.07
Maximum of Months 26.92 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.25 2.60
February 23.40 4.29
March 23.80 8.77
April 24.23 13.91
May 24.24 17.82
June 24.36 23.21
July 24.41 25.63
August 24.39 24.08
September 24.37 20.49
October 24.22 13.71
November 23.90 6.96
December 23.32 2.07
     
Annual Sum or Average 23.99 13.68
Minimum of Months 23.25 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.00 2.60
February 22.30 4.29
March 22.99 8.77
April 24.08 13.91
May 24.21 17.82
June 24.37 23.21
July 24.41 25.63
August 24.38 24.08
September 24.34 20.49
October 23.90 13.71
November 22.86 6.96
December 21.92 2.07
     
Annual Sum or Average 23.49 13.68
Minimum of Months 21.92 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.17 2.60
February 23.32 4.29
March 23.73 8.77
April 24.21 13.91
May 24.27 17.82
June 24.37 23.21
July 24.40 25.63
August 24.41 24.08
September 24.40 20.49
October 24.20 13.71
November 23.83 6.96
December 23.26 2.07
     
Annual Sum or Average 23.97 13.68
Minimum of Months 23.17 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.90 2.60
February 22.17 4.29
March 22.90 8.77
April 24.06 13.91
May 24.23 17.82
June 24.40 23.21
July 24.43 25.63
August 24.39 24.08
September 24.35 20.49
October 23.83 13.71
November 22.67 6.96
December 21.80 2.07
     
Annual Sum or Average 23.43 13.68
Minimum of Months 21.80 2.07
Maximum of Months 24.43 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.94 2.60
February 22.19 4.29
March 22.92 8.77
April 24.01 13.91
May 24.19 17.82
June 24.37 23.21
July 24.42 25.63
August 24.37 24.08
September 24.31 20.49
October 23.86 13.71
November 22.85 6.96
December 21.86 2.07
     
Annual Sum or Average 23.45 13.68
Minimum of Months 21.86 2.07
Maximum of Months 24.42 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.93 2.60
February 22.18 4.29
March 22.91 8.77
April 24.01 13.91
May 24.19 17.82
June 24.37 23.21
July 24.42 25.63
August 24.37 24.08
September 24.31 20.49
October 23.85 13.71
November 22.82 6.96
December 21.85 2.07
     
Annual Sum or Average 23.44 13.68
Minimum of Months 21.85 2.07
Maximum of Months 24.42 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.60 2.60
February 23.72 4.29
March 24.00 8.77
April 24.24 13.91
May 24.23 17.82
June 24.34 23.21
July 24.41 25.63
August 24.42 24.08
September 24.44 20.49
October 24.34 13.71
November 24.13 6.96
December 23.71 2.07
     
Annual Sum or Average 24.13 13.68
Minimum of Months 23.60 2.07
Maximum of Months 24.44 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.59 2.60
February 23.71 4.29
March 23.99 8.77
April 24.24 13.91
May 24.23 17.82
June 24.34 23.21
July 24.41 25.63
August 24.42 24.08
September 24.44 20.49
October 24.34 13.71
November 24.12 6.96
December 23.71 2.07
     
Annual Sum or Average 24.13 13.68
Minimum of Months 23.59 2.07
Maximum of Months 24.44 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 CORRIDOR

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.72 2.60
February 24.02 4.29
March 24.75 8.77
April 25.88 13.91
May 26.13 17.82
June 26.65 23.21
July 26.84 25.63
August 26.78 24.08
September 26.52 20.49
October 25.83 13.71
November 24.73 6.96
December 23.72 2.07
     
Annual Sum or Average 25.47 13.68
Minimum of Months 23.72 2.07
Maximum of Months 26.84 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.19 2.60
February 23.34 4.29
March 23.72 8.77
April 24.20 13.91
May 24.22 17.82
June 24.35 23.21
July 24.41 25.63
August 24.38 24.08
September 24.36 20.49
October 24.20 13.71
November 23.85 6.96
December 23.26 2.07
     
Annual Sum or Average 23.96 13.68
Minimum of Months 23.19 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.97 2.60
February 22.26 4.29
March 22.89 8.77
April 24.03 13.91
May 24.19 17.82
June 24.37 23.21
July 24.41 25.63
August 24.38 24.08
September 24.33 20.49
October 23.86 13.71
November 22.78 6.96
December 21.90 2.07
     
Annual Sum or Average 23.45 13.68
Minimum of Months 21.90 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.11 2.60
February 23.26 4.29
March 23.66 8.77
April 24.19 13.91
May 24.25 17.82
June 24.36 23.21
July 24.40 25.63
August 24.40 24.08
September 24.39 20.49
October 24.18 13.71
November 23.79 6.96
December 23.20 2.07
     
Annual Sum or Average 23.94 13.68
Minimum of Months 23.11 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.87 2.60
February 22.14 4.29
March 22.81 8.77
April 24.02 13.91
May 24.21 17.82
June 24.40 23.21
July 24.43 25.63
August 24.39 24.08
September 24.34 20.49
October 23.79 13.71
November 22.59 6.96
December 21.78 2.07
     
Annual Sum or Average 23.40 13.68
Minimum of Months 21.78 2.07
Maximum of Months 24.43 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.91 2.60
February 22.15 4.29
March 22.80 8.77
April 23.96 13.91
May 24.17 17.82
June 24.36 23.21
July 24.41 25.63
August 24.37 24.08
September 24.31 20.49
October 23.81 13.71
November 22.74 6.96
December 21.83 2.07
     
Annual Sum or Average 23.41 13.68
Minimum of Months 21.83 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.90 2.60
February 22.14 4.29
March 22.79 8.77
April 23.96 13.91
May 24.17 17.82
June 24.36 23.21
July 24.42 25.63
August 24.37 24.08
September 24.31 20.49
October 23.81 13.71
November 22.72 6.96
December 21.83 2.07
     
Annual Sum or Average 23.40 13.68
Minimum of Months 21.83 2.07
Maximum of Months 24.42 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.54 2.60
February 23.66 4.29
March 23.93 8.77
April 24.21 13.91
May 24.21 17.82
June 24.34 23.21
July 24.41 25.63
August 24.41 24.08
September 24.43 20.49
October 24.32 13.71
November 24.08 6.96
December 23.65 2.07
     
Annual Sum or Average 24.10 13.68
Minimum of Months 23.54 2.07
Maximum of Months 24.43 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.53 2.60
February 23.65 4.29
March 23.93 8.77
April 24.21 13.91
May 24.21 17.82
June 24.34 23.21
July 24.41 25.63
August 24.41 24.08
September 24.43 20.49
October 24.32 13.71
November 24.08 6.96
December 23.64 2.07
     
Annual Sum or Average 24.10 13.68
Minimum of Months 23.53 2.07
Maximum of Months 24.43 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 CORRIDOR

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.62 2.60
February 23.91 4.29
March 24.62 8.77
April 25.80 13.91
May 26.09 17.82
June 26.64 23.21
July 26.85 25.63
August 26.78 24.08
September 26.50 20.49
October 25.77 13.71
November 24.61 6.96
December 23.61 2.07
     
Annual Sum or Average 25.41 13.68
Minimum of Months 23.61 2.07
Maximum of Months 26.85 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.07 2.60
February 23.23 4.29
March 23.60 8.77
April 24.15 13.91
May 24.19 17.82
June 24.35 23.21
July 24.41 25.63
August 24.38 24.08
September 24.36 20.49
October 24.16 13.71
November 23.75 6.96
December 23.14 2.07
     
Annual Sum or Average 23.90 13.68
Minimum of Months 23.07 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.94 2.60
February 22.23 4.29
March 22.80 8.77
April 23.96 13.91
May 24.16 17.82
June 24.36 23.21
July 24.41 25.63
August 24.38 24.08
September 24.33 20.49
October 23.81 13.71
November 22.68 6.96
December 21.88 2.07
     
Annual Sum or Average 23.42 13.68
Minimum of Months 21.88 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.00 2.60
February 23.15 4.29
March 23.54 8.77
April 24.14 13.91
May 24.22 17.82
June 24.36 23.21
July 24.40 25.63
August 24.40 24.08
September 24.38 20.49
October 24.14 13.71
November 23.69 6.96
December 23.09 2.07
     
Annual Sum or Average 23.88 13.68
Minimum of Months 23.00 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.84 2.60
February 22.11 4.29
March 22.71 8.77
April 23.96 13.91
May 24.18 17.82
June 24.40 23.21
July 24.44 25.63
August 24.39 24.08
September 24.34 20.49
October 23.73 13.71
November 22.49 6.96
December 21.77 2.07
     
Annual Sum or Average 23.37 13.68
Minimum of Months 21.77 2.07
Maximum of Months 24.44 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.87 2.60
February 22.11 4.29
March 22.69 8.77
April 23.88 13.91
May 24.14 17.82
June 24.36 23.21
July 24.41 25.63
August 24.37 24.08
September 24.30 20.49
October 23.74 13.71
November 22.61 6.96
December 21.81 2.07
     
Annual Sum or Average 23.36 13.68
Minimum of Months 21.81 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.87 2.60
February 22.10 4.29
March 22.69 8.77
April 23.88 13.91
May 24.14 17.82
June 24.36 23.21
July 24.41 25.63
August 24.37 24.08
September 24.30 20.49
October 23.74 13.71
November 22.60 6.96
December 21.80 2.07
     
Annual Sum or Average 23.36 13.68
Minimum of Months 21.80 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.39 2.60
February 23.51 4.29
March 23.80 8.77
April 24.16 13.91
May 24.18 17.82
June 24.33 23.21
July 24.41 25.63
August 24.41 24.08
September 24.41 20.49
October 24.27 13.71
November 23.97 6.96
December 23.48 2.07
     
Annual Sum or Average 24.03 13.68
Minimum of Months 23.39 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.38 2.60
February 23.51 4.29
March 23.80 8.77
April 24.16 13.91
May 24.19 17.82
June 24.33 23.21
July 24.41 25.63
August 24.41 24.08
September 24.41 20.49
October 24.27 13.71
November 23.97 6.96
December 23.48 2.07
     
Annual Sum or Average 24.03 13.68
Minimum of Months 23.38 2.07
Maximum of Months 24.41 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 CORRIDOR

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.41 2.60
February 23.72 4.29
March 24.45 8.77
April 25.72 13.91
May 26.09 17.82
June 26.72 23.21
July 26.96 25.63
August 26.87 24.08
September 26.54 20.49
October 25.67 13.71
November 24.40 6.96
December 23.39 2.07
     
Annual Sum or Average 25.34 13.68
Minimum of Months 23.39 2.07
Maximum of Months 26.96 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.73 2.60
February 22.90 4.29
March 23.14 8.77
April 23.85 13.91
May 24.08 17.82
June 24.30 23.21
July 24.40 25.63
August 24.36 24.08
September 24.32 20.49
October 23.88 13.71
November 23.25 6.96
December 22.78 2.07
     
Annual Sum or Average 23.67 13.68
Minimum of Months 22.73 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.10 2.60
February 22.32 4.29
March 22.72 8.77
April 23.70 13.91
May 24.04 17.82
June 24.32 23.21
July 24.40 25.63
August 24.36 24.08
September 24.29 20.49
October 23.59 13.71
November 22.62 6.96
December 21.99 2.07
     
Annual Sum or Average 23.38 13.68
Minimum of Months 21.99 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.71 2.60
February 22.89 4.29
March 23.13 8.77
April 23.85 13.91
May 24.09 17.82
June 24.31 23.21
July 24.39 25.63
August 24.38 24.08
September 24.34 20.49
October 23.85 13.71
November 23.22 6.96
December 22.77 2.07
     
Annual Sum or Average 23.66 13.68
Minimum of Months 22.71 2.07
Maximum of Months 24.39 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.98 2.60
February 22.24 4.29
March 22.70 8.77
April 23.70 13.91
May 24.03 17.82
June 24.33 23.21
July 24.42 25.63
August 24.37 24.08
September 24.28 20.49
October 23.55 13.71
November 22.49 6.96
December 21.82 2.07
     
Annual Sum or Average 23.33 13.68
Minimum of Months 21.82 2.07
Maximum of Months 24.42 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.97 2.60
February 22.21 4.29
March 22.63 8.77
April 23.64 13.91
May 24.01 17.82
June 24.31 23.21
July 24.40 25.63
August 24.35 24.08
September 24.26 20.49
October 23.54 13.71
November 22.51 6.96
December 21.84 2.07
     
Annual Sum or Average 23.31 13.68
Minimum of Months 21.84 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.97 2.60
February 22.20 4.29
March 22.63 8.77
April 23.64 13.91
May 24.02 17.82
June 24.31 23.21
July 24.40 25.63
August 24.35 24.08
September 24.26 20.49
October 23.54 13.71
November 22.50 6.96
December 21.83 2.07
     
Annual Sum or Average 23.31 13.68
Minimum of Months 21.83 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.88 2.60
February 23.04 4.29
March 23.29 8.77
April 23.90 13.91
May 24.08 17.82
June 24.29 23.21
July 24.39 25.63
August 24.37 24.08
September 24.35 20.49
October 23.99 13.71
November 23.42 6.96
December 22.94 2.07
     
Annual Sum or Average 23.75 13.68
Minimum of Months 22.88 2.07
Maximum of Months 24.39 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.88 2.60
February 23.04 4.29
March 23.30 8.77
April 23.90 13.91
May 24.09 17.82
June 24.29 23.21
July 24.39 25.63
August 24.37 24.08
September 24.35 20.49
October 23.99 13.71
November 23.42 6.96
December 22.94 2.07
     
Annual Sum or Average 23.75 13.68
Minimum of Months 22.88 2.07
Maximum of Months 24.39 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.23 2.60
February 23.70 4.29
March 24.54 8.77
April 26.05 13.91
May 26.64 17.82
June 27.52 23.21
July 27.89 25.63
August 27.75 24.08
September 27.19 20.49
October 25.92 13.71
November 24.32 6.96
December 23.16 2.07
     
Annual Sum or Average 25.67 13.68
Minimum of Months 23.16 2.07
Maximum of Months 27.89 25.63



Table of Contents

Report: COMPONENTS OF PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2018-10-19 09:40:08

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY {AT MAX/MIN} [W] HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W]
January 0.237169E+12 130472.786 16-JAN-18:15 22204.399 56867.515 22185.692 15956.414 0.000 10720.100 1393.029 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
February 0.210733E+12 136384.175 13-FEB-18:15 22204.399 56867.515 22185.692 0.000 21261.760 10720.100 1393.029 606.043 0.000 0.000 0.000 0.000 0.000 0.000 0.000
March 0.224605E+12 133979.800 11-MAR-18:15 22204.399 56867.515 22185.692 0.000 18945.256 10720.100 1393.029 518.173 0.000 0.000 0.000 0.000 0.000 0.000 0.000
April 0.235395E+12 162221.941 13-APR-17:15 22204.399 56867.515 22185.692 0.000 56789.242 0.000 1393.029 1636.427 0.000 0.000 0.000 0.000 0.000 0.000 0.000
May 0.260386E+12 166716.692 15-MAY-18:00 25049.151 51564.864 22185.692 0.000 53201.550 10720.100 1393.029 1587.691 0.000 0.000 0.000 0.000 0.000 0.000 0.000
June 0.286543E+12 170392.020 18-JUN-19:00 25049.151 49704.829 22185.692 0.000 58785.509 10720.100 1393.029 1608.137 0.000 0.000 0.000 0.000 0.000 0.000 0.000
July 0.320301E+12 171347.369 21-JUL-19:15 25049.151 49704.829 22185.692 0.000 59469.484 10720.100 1393.029 1879.511 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 0.311567E+12 170218.882 17-AUG-18:00 25049.151 51564.864 22185.692 0.000 56390.312 10720.100 1393.029 1901.119 0.000 0.000 0.000 0.000 0.000 0.000 0.000
September 0.276042E+12 166673.626 28-SEP-17:00 22204.399 56867.515 22185.692 0.000 50447.099 10720.100 1393.029 1709.903 0.000 0.000 0.000 0.000 0.000 0.000 0.000
October 0.254150E+12 167059.450 05-OCT-17:45 22204.399 56867.515 22185.692 0.000 50949.277 10720.100 1393.029 1593.549 0.000 0.000 0.000 0.000 0.000 0.000 0.000
November 0.227893E+12 137235.574 02-NOV-17:45 22204.399 56867.515 22185.692 0.000 21980.893 10720.100 1393.029 738.057 0.000 0.000 0.000 0.000 0.000 0.000 0.000
December 0.236865E+12 128436.112 31-DEC-18:15 22204.399 56867.515 22185.692 0.000 13463.748 10720.100 1393.029 455.993 0.000 0.000 0.000 0.000 0.000 0.000 0.000
                                     
Annual Sum or Average 0.308165E+13                     0.000 0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.210733E+12 128436.112   22204.399 49704.829 22185.692 0.000 0.000 0.000 1393.029 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.320301E+12 171347.369   25049.151 56867.515 22185.692 15956.414 59469.484 10720.100 1393.029 1901.119 0.000 0.000 0.000 0.000 0.000 0.000 0.000



Table of Contents

Report: COMPONENTS OF PEAK GAS DEMAND

For: Meter

Timestamp: 2018-10-19 09:40:08

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC [Invalid/Undefined] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT {AT MAX/MIN} [W] WATERSYSTEMS:GAS {AT MAX/MIN} [W] WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] HEATING:GAS {AT MAX/MIN} [W]
January 0.139627E+12 174185.847 17-JAN-07:00 0.000 0.000 0.000 174185.847 86775.670 86775.670 87410.178
February 0.116033E+12 162259.267 06-FEB-07:15 0.000 0.000 0.000 162259.267 85871.086 85871.086 76388.180
March 0.105969E+12 112812.620 04-MAR-07:15 0.000 0.000 0.000 112812.620 85422.328 85422.328 27390.292
April 0.960973E+11 85039.522 03-APR-06:00 0.000 0.000 0.000 85039.522 85039.522 85039.522 0.000
May 0.923582E+11 82656.354 03-MAY-06:30 0.000 0.000 0.000 82656.354 82656.354 82656.354 0.000
June 0.831437E+11 80576.604 03-JUN-06:45 0.000 0.000 0.000 80576.604 80576.604 80576.604 0.000
July 0.816351E+11 79051.018 02-JUL-06:00 0.000 0.000 0.000 79051.018 79051.018 79051.018 0.000
August 0.807378E+11 78554.494 31-AUG-06:45 0.000 0.000 0.000 78554.494 78554.494 78554.494 0.000
September 0.807261E+11 79722.266 28-SEP-06:00 0.000 0.000 0.000 79722.266 79722.266 79722.266 0.000
October 0.899689E+11 107114.289 26-OCT-05:00 0.000 0.000 0.000 107114.289 79577.887 79577.887 27536.402
November 0.952883E+11 121253.649 26-NOV-07:15 0.000 0.000 0.000 121253.649 82648.696 82648.696 38604.953
December 0.131457E+12 161025.081 22-DEC-07:30 0.000 0.000 0.000 161025.081 85376.451 85376.451 75648.630
                     
Annual Sum or Average 0.119304E+13     0.000 0.000 0.000        
Minimum of Months 0.807261E+11 78554.494   0.000 0.000 0.000 78554.494 78554.494 78554.494 0.000
Maximum of Months 0.139627E+12 174185.847   0.000 0.000 0.000 174185.847 86775.670 86775.670 87410.178