Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:37

Tabular Output Report in Format: HTML

Building: High-Rise Apartment

Environment: Buffalo Niagara Intl AP NY USA TMY3 WMO#=725280

Simulation Timestamp: 2018-10-19 09:40:07


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:07

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 5205.80 664.30 737.38
Net Site Energy 5205.80 664.30 737.38
Total Source Energy 11739.32 1498.04 1662.82
Net Source Energy 11739.32 1498.04 1662.82


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 7836.48
Net Conditioned Building Area 7059.89
Unconditioned Building Area 776.58


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 292.18 1050.73 0.00 0.00 0.00 0.00
Cooling 265.22 0.00 0.00 0.00 0.00 0.00
Interior Lighting 416.41 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 168.23 0.00 0.00 0.00 0.00 0.00
Interior Equipment 1131.09 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 571.40 0.00 0.00 0.00 0.00 0.00
Pumps 49.85 0.00 0.00 0.00 0.00 0.00
Heat Rejection 11.44 0.00 0.00 0.00 0.00 762.95
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 1228.41 0.00 0.00 0.00 4778.51
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 2926.66 2279.14 0.00 0.00 0.00 5541.46
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating Boiler 0.00 1050.73 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
  Other 292.18 0.00 0.00 0.00 0.00 0.00
Cooling General 265.22 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 348.50 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 67.92 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 168.23 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 1131.09 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 571.40 0.00 0.00 0.00 0.00 0.00
Pumps General 49.85 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 11.44 0.00 0.00 0.00 0.00 762.95
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 1228.41 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 4778.51
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 82.81 0.00 0.00 0.00 0.00 0.00
HVAC 168.57 322.83 0.00 0.00 0.00 0.78
Other 160.21 0.00 0.00 0.00 0.00 0.00
Total 414.55 322.83 0.00 0.00 0.00 0.78


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 74.61 0.00 0.00 0.00 0.00 0.00
HVAC 151.87 290.84 0.00 0.00 0.00 0.71
Other 144.34 0.00 0.00 0.00 0.00 0.00
Total 373.47 290.84 0.00 0.00 0.00 0.71


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 2926.66 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 2926.66 100.00
     
Total On-Site and Utility Electric Sources 2926.66 100.00
Total Electricity End Uses 2926.66 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 5541.46 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 5541.46 100.00
Total Water End Uses 5541.46 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 139.25
Time Setpoint Not Met During Occupied Cooling 79.75
Time Not Comfortable Based on Simple ASHRAE 55-2004 2723.25


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |

COMPONENTS OF PEAK ELECTRICAL DEMAND

| Meter |

COMPONENTS OF PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:07

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:37
RunPeriod Buffalo Niagara Intl AP NY USA TMY3 WMO#=725280
Weather File Buffalo Niagara Intl AP NY USA TMY3 WMO#=725280
Latitude [deg] 42.93
Longitude [deg] -78.7
Elevation [m] 215.00
Time Zone -5.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3855.02 1411.96 515.55 1411.96 515.55
Window Opening Area [m2] 1150.39 423.59 152.73 423.59 150.48
Window-Wall Ratio [%] 29.84 30.00 29.62 30.00 29.19


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3752.84 1411.96 464.46 1411.96 464.46
Window Opening Area [m2] 1125.85 423.59 139.34 423.59 139.34
Window-Wall Ratio [%] 30.00 30.00 30.00 30.00 30.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
OFFICE 88.25 Yes Yes 268.96 1.00 58.52 17.56 23.8959 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 4.47 8.5250   0.0000
F2 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F2 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F2 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F2 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F2 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F2 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F2 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F2 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F2 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   0.0000
F3 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F3 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F3 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F3 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F3 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F3 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F3 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F3 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F3 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   0.0000
F4 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F4 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F4 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F4 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F4 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F4 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F4 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F4 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F4 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   0.0000
M SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
M CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 17.0500   0.0000
F6 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F6 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F6 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F6 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F6 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F6 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F6 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F6 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F6 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   0.0000
F7 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F7 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F7 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F7 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F7 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F7 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F7 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F7 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F7 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   0.0000
F8 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F8 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F8 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F8 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F8 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F8 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F8 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F8 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F8 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   0.0000
F9 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F9 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F9 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F9 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F9 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F9 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F9 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F9 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F9 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   0.0000
T SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   263.6661
Total 7836.48     23884.04   3855.02 1150.39 14.0302 39.48 8.6219
Conditioned Total 7059.89     21517.16   3752.84 1125.85 14.5420 35.57 6.6700
Unconditioned Total 776.58     2366.87   102.18 24.54 9.3775   26.3666
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:07

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 13-AUG-19:30 06-FEB-09:45 - - - 21-JUL-06:00
Heating 0.00 245225.97 0.00 0.00 0.00 0.00
Cooling 68352.22 0.00 0.00 0.00 0.00 0.00
Interior Lighting 25049.15 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 10720.10 0.00 0.00 0.00 0.00 0.00
Interior Equipment 49704.83 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 18118.97 0.00 0.00 0.00 0.00 0.00
Pumps 1621.88 0.00 0.00 0.00 0.00 0.00
Heat Rejection 2725.24 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 83981.72 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 177237.97 329207.69 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating Boiler 0.00 245225.97 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 68352.22 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 20603.34 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 4445.81 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 10720.10 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 49704.83 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 18118.97 0.00 0.00 0.00 0.00 0.00
Pumps General 1621.88 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 2725.24 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 83981.72 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:07

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 925.34 1138.99 0.00 0.00 0.00
Cooling 839.95 0.00 0.00 0.00 0.00
Interior Lighting 1318.78 0.00 0.00 0.00 0.00
Exterior Lighting 532.80 0.00 0.00 0.00 0.00
Interior Equipment 3582.17 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 1809.62 0.00 0.00 0.00 0.00
Pumps 157.88 0.00 0.00 0.00 0.00
Heat Rejection 36.25 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 1331.60 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 9268.73 2470.59 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 131.07 161.33 0.00 0.00 0.00
Cooling 118.97 0.00 0.00 0.00 0.00
Interior Lighting 186.80 0.00 0.00 0.00 0.00
Exterior Lighting 75.47 0.00 0.00 0.00 0.00
Interior Equipment 507.40 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 256.32 0.00 0.00 0.00 0.00
Pumps 22.36 0.00 0.00 0.00 0.00
Heat Rejection 5.13 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 188.61 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1312.87 349.95 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 131.07 161.33 0.00 0.00 0.00
Cooling 118.97 0.00 0.00 0.00 0.00
Interior Lighting 186.80 0.00 0.00 0.00 0.00
Exterior Lighting 75.47 0.00 0.00 0.00 0.00
Interior Equipment 507.40 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 256.32 0.00 0.00 0.00 0.00
Pumps 22.36 0.00 0.00 0.00 0.00
Heat Rejection 5.13 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 188.61 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1312.87 349.95 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:07

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB -16.30 0.00 -16.30 Wetbulb [C] 5.10 270.00
BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 30.30 9.30 21.80 Wetbulb [C] 5.70 240.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:07

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 270.00 180.00  
F2 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F2 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F2 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F2 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F2 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F2 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F3 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F3 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F3 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F3 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F3 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F3 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F4 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F4 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F4 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F4 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F4 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F4 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
M WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F6 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F6 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F6 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F6 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F6 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F6 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F7 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F7 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F7 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F7 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F7 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F7 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F8 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F8 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F8 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F8 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F8 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F8 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F9 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F9 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F9 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F9 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F9 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F9 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.30 0.269 0.283 77.66 0.00 0.00  


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL SWA 180.00 90.00 S
GWINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G WWALL SWA 270.00 90.00 W
GWINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL NWA 0.00 90.00 N
GWINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G WWALL NWA 270.00 90.00 W
GWINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL SEA 180.00 90.00 S
GWINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G EWALL SEA 90.00 90.00 E
GWINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL NEA 0.00 90.00 N
GWINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G EWALL NEA 90.00 90.00 E
GWINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL N1A 0.00 90.00 N
GWINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL N2A 0.00 90.00 N
GWINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL S1A 180.00 90.00 S
GWINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL S2A 180.00 90.00 S
GWINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No G WWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.48_SHGC_0.40 3.36 0.00 0.00 3.36 3.36 2.653 0.426 0.308     No G EWALL C 90.00 90.00 E
F2WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 WWALL SWA 270.00 90.00 W
F2WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL SWA 180.00 90.00 S
F2WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL NWA 0.00 90.00 N
F2WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 WWALL NWA 270.00 90.00 W
F2WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 EWALL SEA 90.00 90.00 E
F2WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL SEA 180.00 90.00 S
F2WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL NEA 0.00 90.00 N
F2WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 EWALL NEA 90.00 90.00 E
F2WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL N1A 0.00 90.00 N
F2WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL N2A 0.00 90.00 N
F2WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL S1A 180.00 90.00 S
F2WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL S2A 180.00 90.00 S
F2WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F2 WWALL C 270.00 90.00 W
F2WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F2 EWALL C 90.00 90.00 E
F3WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 WWALL SWA 270.00 90.00 W
F3WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL SWA 180.00 90.00 S
F3WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL NWA 0.00 90.00 N
F3WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 WWALL NWA 270.00 90.00 W
F3WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 EWALL SEA 90.00 90.00 E
F3WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL SEA 180.00 90.00 S
F3WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL NEA 0.00 90.00 N
F3WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 EWALL NEA 90.00 90.00 E
F3WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL N1A 0.00 90.00 N
F3WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL N2A 0.00 90.00 N
F3WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL S1A 180.00 90.00 S
F3WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL S2A 180.00 90.00 S
F3WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F3 WWALL C 270.00 90.00 W
F3WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F3 EWALL C 90.00 90.00 E
F4WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 WWALL SWA 270.00 90.00 W
F4WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL SWA 180.00 90.00 S
F4WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL NWA 0.00 90.00 N
F4WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 WWALL NWA 270.00 90.00 W
F4WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 EWALL SEA 90.00 90.00 E
F4WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL SEA 180.00 90.00 S
F4WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL NEA 0.00 90.00 N
F4WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 EWALL NEA 90.00 90.00 E
F4WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL N1A 0.00 90.00 N
F4WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL N2A 0.00 90.00 N
F4WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL S1A 180.00 90.00 S
F4WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL S2A 180.00 90.00 S
F4WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F4 WWALL C 270.00 90.00 W
F4WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F4 EWALL C 90.00 90.00 E
MWINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M WWALL SWA 270.00 90.00 W
MWINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL SWA 180.00 90.00 S
MWINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL NWA 0.00 90.00 N
MWINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M WWALL NWA 270.00 90.00 W
MWINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M EWALL SEA 90.00 90.00 E
MWINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL SEA 180.00 90.00 S
MWINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL NEA 0.00 90.00 N
MWINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M EWALL NEA 90.00 90.00 E
MWINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL N1A 0.00 90.00 N
MWINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL N2A 0.00 90.00 N
MWINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL S1A 180.00 90.00 S
MWINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL S2A 180.00 90.00 S
MWINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No M WWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No M EWALL C 90.00 90.00 E
F6WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 WWALL SWA 270.00 90.00 W
F6WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL SWA 180.00 90.00 S
F6WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL NWA 0.00 90.00 N
F6WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 WWALL NWA 270.00 90.00 W
F6WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 EWALL SEA 90.00 90.00 E
F6WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL SEA 180.00 90.00 S
F6WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL NEA 0.00 90.00 N
F6WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 EWALL NEA 90.00 90.00 E
F6WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL N1A 0.00 90.00 N
F6WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL N2A 0.00 90.00 N
F6WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL S1A 180.00 90.00 S
F6WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL S2A 180.00 90.00 S
F6WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F6 WWALL C 270.00 90.00 W
F6WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F6 EWALL C 90.00 90.00 E
F7WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 WWALL SWA 270.00 90.00 W
F7WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL SWA 180.00 90.00 S
F7WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL NWA 0.00 90.00 N
F7WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 WWALL NWA 270.00 90.00 W
F7WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 EWALL SEA 90.00 90.00 E
F7WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL SEA 180.00 90.00 S
F7WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL NEA 0.00 90.00 N
F7WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 EWALL NEA 90.00 90.00 E
F7WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL N1A 0.00 90.00 N
F7WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL N2A 0.00 90.00 N
F7WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL S1A 180.00 90.00 S
F7WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL S2A 180.00 90.00 S
F7WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F7 WWALL C 270.00 90.00 W
F7WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F7 EWALL C 90.00 90.00 E
F8WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 WWALL SWA 270.00 90.00 W
F8WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL SWA 180.00 90.00 S
F8WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL NWA 0.00 90.00 N
F8WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 WWALL NWA 270.00 90.00 W
F8WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 EWALL SEA 90.00 90.00 E
F8WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL SEA 180.00 90.00 S
F8WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL NEA 0.00 90.00 N
F8WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 EWALL NEA 90.00 90.00 E
F8WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL N1A 0.00 90.00 N
F8WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL N2A 0.00 90.00 N
F8WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL S1A 180.00 90.00 S
F8WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL S2A 180.00 90.00 S
F8WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F8 WWALL C 270.00 90.00 W
F8WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F8 EWALL C 90.00 90.00 E
F9WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 WWALL SWA 270.00 90.00 W
F9WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL SWA 180.00 90.00 S
F9WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL NWA 0.00 90.00 N
F9WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 WWALL NWA 270.00 90.00 W
F9WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 EWALL SEA 90.00 90.00 E
F9WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL SEA 180.00 90.00 S
F9WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL NEA 0.00 90.00 N
F9WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 EWALL NEA 90.00 90.00 E
F9WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL N1A 0.00 90.00 N
F9WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL N2A 0.00 90.00 N
F9WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL S1A 180.00 90.00 S
F9WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL S2A 180.00 90.00 S
F9WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F9 WWALL C 270.00 90.00 W
F9WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F9 EWALL C 90.00 90.00 E
TWINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T WWALL SWA 270.00 90.00 W
TWINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL SWA 180.00 90.00 S
TWINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL NWA 0.00 90.00 N
TWINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T WWALL NWA 270.00 90.00 W
TWINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T EWALL SEA 90.00 90.00 E
TWINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL SEA 180.00 90.00 S
TWINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL NEA 0.00 90.00 N
TWINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T EWALL NEA 90.00 90.00 E
TWINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL N1A 0.00 90.00 N
TWINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL N2A 0.00 90.00 N
TWINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL S1A 180.00 90.00 S
TWINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL S2A 180.00 90.00 S
TWINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No T WWALL C 270.00 90.00 W
TWINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No T EWALL C 90.00 90.00 E
Total or Average           1150.39 2.653 0.426 0.308              
North Total or Average           423.59 2.653 0.426 0.308              
Non-North Total or Average           726.80 2.653 0.426 0.308              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:07

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:07

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
G SW APARTMENT_LIGHTS_HARDWIRED G SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
G NW APARTMENT_LIGHTS_HARDWIRED G NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
OFFICE_LIGHTS_HARDWIRED OFFICE 11.9479 88.25 1054.39 GeneralLights LTG_OFF_SCH 56.26 168.00 55.46 0.0000 Y 10.98
G NE APARTMENT_LIGHTS_HARDWIRED G NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
G N1 APARTMENT_LIGHTS_HARDWIRED G N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
G N2 APARTMENT_LIGHTS_HARDWIRED G N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
G S1 APARTMENT_LIGHTS_HARDWIRED G S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
G S2 APARTMENT_LIGHTS_HARDWIRED G S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
G CORRIDOR_LIGHTS_HARDWIRED G CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F2 SW APARTMENT_LIGHTS_HARDWIRED F2 SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 NW APARTMENT_LIGHTS_HARDWIRED F2 NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 SE APARTMENT_LIGHTS_HARDWIRED F2 SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 NE APARTMENT_LIGHTS_HARDWIRED F2 NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 N1 APARTMENT_LIGHTS_HARDWIRED F2 N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 N2 APARTMENT_LIGHTS_HARDWIRED F2 N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 S1 APARTMENT_LIGHTS_HARDWIRED F2 S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 S2 APARTMENT_LIGHTS_HARDWIRED F2 S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 CORRIDOR_LIGHTS_HARDWIRED F2 CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F3 SW APARTMENT_LIGHTS_HARDWIRED F3 SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 NW APARTMENT_LIGHTS_HARDWIRED F3 NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 SE APARTMENT_LIGHTS_HARDWIRED F3 SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 NE APARTMENT_LIGHTS_HARDWIRED F3 NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 N1 APARTMENT_LIGHTS_HARDWIRED F3 N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 N2 APARTMENT_LIGHTS_HARDWIRED F3 N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 S1 APARTMENT_LIGHTS_HARDWIRED F3 S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 S2 APARTMENT_LIGHTS_HARDWIRED F3 S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 CORRIDOR_LIGHTS_HARDWIRED F3 CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F4 SW APARTMENT_LIGHTS_HARDWIRED F4 SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 NW APARTMENT_LIGHTS_HARDWIRED F4 NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 SE APARTMENT_LIGHTS_HARDWIRED F4 SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 NE APARTMENT_LIGHTS_HARDWIRED F4 NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 N1 APARTMENT_LIGHTS_HARDWIRED F4 N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 N2 APARTMENT_LIGHTS_HARDWIRED F4 N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 S1 APARTMENT_LIGHTS_HARDWIRED F4 S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 S2 APARTMENT_LIGHTS_HARDWIRED F4 S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 CORRIDOR_LIGHTS_HARDWIRED F4 CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
M SW APARTMENT_LIGHTS_HARDWIRED M SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M NW APARTMENT_LIGHTS_HARDWIRED M NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M SE APARTMENT_LIGHTS_HARDWIRED M SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M NE APARTMENT_LIGHTS_HARDWIRED M NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M N1 APARTMENT_LIGHTS_HARDWIRED M N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M N2 APARTMENT_LIGHTS_HARDWIRED M N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M S1 APARTMENT_LIGHTS_HARDWIRED M S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M S2 APARTMENT_LIGHTS_HARDWIRED M S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M CORRIDOR_LIGHTS_HARDWIRED M CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F6 SW APARTMENT_LIGHTS_HARDWIRED F6 SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 NW APARTMENT_LIGHTS_HARDWIRED F6 NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 SE APARTMENT_LIGHTS_HARDWIRED F6 SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 NE APARTMENT_LIGHTS_HARDWIRED F6 NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 N1 APARTMENT_LIGHTS_HARDWIRED F6 N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 N2 APARTMENT_LIGHTS_HARDWIRED F6 N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 S1 APARTMENT_LIGHTS_HARDWIRED F6 S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 S2 APARTMENT_LIGHTS_HARDWIRED F6 S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 CORRIDOR_LIGHTS_HARDWIRED F6 CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F7 SW APARTMENT_LIGHTS_HARDWIRED F7 SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 NW APARTMENT_LIGHTS_HARDWIRED F7 NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 SE APARTMENT_LIGHTS_HARDWIRED F7 SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 NE APARTMENT_LIGHTS_HARDWIRED F7 NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 N1 APARTMENT_LIGHTS_HARDWIRED F7 N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 N2 APARTMENT_LIGHTS_HARDWIRED F7 N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 S1 APARTMENT_LIGHTS_HARDWIRED F7 S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 S2 APARTMENT_LIGHTS_HARDWIRED F7 S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 CORRIDOR_LIGHTS_HARDWIRED F7 CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F8 SW APARTMENT_LIGHTS_HARDWIRED F8 SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 NW APARTMENT_LIGHTS_HARDWIRED F8 NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 SE APARTMENT_LIGHTS_HARDWIRED F8 SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 NE APARTMENT_LIGHTS_HARDWIRED F8 NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 N1 APARTMENT_LIGHTS_HARDWIRED F8 N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 N2 APARTMENT_LIGHTS_HARDWIRED F8 N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 S1 APARTMENT_LIGHTS_HARDWIRED F8 S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 S2 APARTMENT_LIGHTS_HARDWIRED F8 S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 CORRIDOR_LIGHTS_HARDWIRED F8 CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F9 SW APARTMENT_LIGHTS_HARDWIRED F9 SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 NW APARTMENT_LIGHTS_HARDWIRED F9 NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 SE APARTMENT_LIGHTS_HARDWIRED F9 SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 NE APARTMENT_LIGHTS_HARDWIRED F9 NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 N1 APARTMENT_LIGHTS_HARDWIRED F9 N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 N2 APARTMENT_LIGHTS_HARDWIRED F9 N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 S1 APARTMENT_LIGHTS_HARDWIRED F9 S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 S2 APARTMENT_LIGHTS_HARDWIRED F9 S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 CORRIDOR_LIGHTS_HARDWIRED F9 CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
T SW APARTMENT_LIGHTS_HARDWIRED T SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T NW APARTMENT_LIGHTS_HARDWIRED T NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T SE APARTMENT_LIGHTS_HARDWIRED T SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T NE APARTMENT_LIGHTS_HARDWIRED T NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T N1 APARTMENT_LIGHTS_HARDWIRED T N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T N2 APARTMENT_LIGHTS_HARDWIRED T N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T S1 APARTMENT_LIGHTS_HARDWIRED T S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T S2 APARTMENT_LIGHTS_HARDWIRED T S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T CORRIDOR_LIGHTS_HARDWIRED T CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
G SW APARTMENT_LIGHTS_PLUGIN G SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
G NW APARTMENT_LIGHTS_PLUGIN G NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
OFFICE_LIGHTS_PLUGIN OFFICE 11.9479 88.25 1054.39 GeneralLights-plugin LTG_OFF_SCH 56.26 168.00 55.46 0.0000 Y 10.98
G NE APARTMENT_LIGHTS_PLUGIN G NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
G N1 APARTMENT_LIGHTS_PLUGIN G N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
G N2 APARTMENT_LIGHTS_PLUGIN G N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
G S1 APARTMENT_LIGHTS_PLUGIN G S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
G S2 APARTMENT_LIGHTS_PLUGIN G S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 SW APARTMENT_LIGHTS_PLUGIN F2 SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 NW APARTMENT_LIGHTS_PLUGIN F2 NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 SE APARTMENT_LIGHTS_PLUGIN F2 SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 NE APARTMENT_LIGHTS_PLUGIN F2 NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 N1 APARTMENT_LIGHTS_PLUGIN F2 N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 N2 APARTMENT_LIGHTS_PLUGIN F2 N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 S1 APARTMENT_LIGHTS_PLUGIN F2 S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 S2 APARTMENT_LIGHTS_PLUGIN F2 S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 SW APARTMENT_LIGHTS_PLUGIN F3 SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 NW APARTMENT_LIGHTS_PLUGIN F3 NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 SE APARTMENT_LIGHTS_PLUGIN F3 SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 NE APARTMENT_LIGHTS_PLUGIN F3 NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 N1 APARTMENT_LIGHTS_PLUGIN F3 N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 N2 APARTMENT_LIGHTS_PLUGIN F3 N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 S1 APARTMENT_LIGHTS_PLUGIN F3 S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 S2 APARTMENT_LIGHTS_PLUGIN F3 S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 SW APARTMENT_LIGHTS_PLUGIN F4 SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 NW APARTMENT_LIGHTS_PLUGIN F4 NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 SE APARTMENT_LIGHTS_PLUGIN F4 SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 NE APARTMENT_LIGHTS_PLUGIN F4 NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 N1 APARTMENT_LIGHTS_PLUGIN F4 N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 N2 APARTMENT_LIGHTS_PLUGIN F4 N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 S1 APARTMENT_LIGHTS_PLUGIN F4 S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 S2 APARTMENT_LIGHTS_PLUGIN F4 S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M SW APARTMENT_LIGHTS_PLUGIN M SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M NW APARTMENT_LIGHTS_PLUGIN M NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M SE APARTMENT_LIGHTS_PLUGIN M SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M NE APARTMENT_LIGHTS_PLUGIN M NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M N1 APARTMENT_LIGHTS_PLUGIN M N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M N2 APARTMENT_LIGHTS_PLUGIN M N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M S1 APARTMENT_LIGHTS_PLUGIN M S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M S2 APARTMENT_LIGHTS_PLUGIN M S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M CORRIDOR_LIGHTS_PLUGIN M CORRIDOR 8.5250 77.66 662.04 GeneralLights-plugin LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F6 SW APARTMENT_LIGHTS_PLUGIN F6 SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F6 NW APARTMENT_LIGHTS_PLUGIN F6 NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F6 SE APARTMENT_LIGHTS_PLUGIN F6 SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F6 NE APARTMENT_LIGHTS_PLUGIN F6 NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F6 N1 APARTMENT_LIGHTS_PLUGIN F6 N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F6 N2 APARTMENT_LIGHTS_PLUGIN F6 N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F6 S1 APARTMENT_LIGHTS_PLUGIN F6 S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F6 S2 APARTMENT_LIGHTS_PLUGIN F6 S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 SW APARTMENT_LIGHTS_PLUGIN F7 SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 NW APARTMENT_LIGHTS_PLUGIN F7 NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 SE APARTMENT_LIGHTS_PLUGIN F7 SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 NE APARTMENT_LIGHTS_PLUGIN F7 NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 N1 APARTMENT_LIGHTS_PLUGIN F7 N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 N2 APARTMENT_LIGHTS_PLUGIN F7 N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 S1 APARTMENT_LIGHTS_PLUGIN F7 S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 S2 APARTMENT_LIGHTS_PLUGIN F7 S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 SW APARTMENT_LIGHTS_PLUGIN F8 SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 NW APARTMENT_LIGHTS_PLUGIN F8 NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 SE APARTMENT_LIGHTS_PLUGIN F8 SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 NE APARTMENT_LIGHTS_PLUGIN F8 NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 N1 APARTMENT_LIGHTS_PLUGIN F8 N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 N2 APARTMENT_LIGHTS_PLUGIN F8 N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 S1 APARTMENT_LIGHTS_PLUGIN F8 S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 S2 APARTMENT_LIGHTS_PLUGIN F8 S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 SW APARTMENT_LIGHTS_PLUGIN F9 SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 NW APARTMENT_LIGHTS_PLUGIN F9 NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 SE APARTMENT_LIGHTS_PLUGIN F9 SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 NE APARTMENT_LIGHTS_PLUGIN F9 NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 N1 APARTMENT_LIGHTS_PLUGIN F9 N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 N2 APARTMENT_LIGHTS_PLUGIN F9 N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 S1 APARTMENT_LIGHTS_PLUGIN F9 S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 S2 APARTMENT_LIGHTS_PLUGIN F9 S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T SW APARTMENT_LIGHTS_PLUGIN T SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T NW APARTMENT_LIGHTS_PLUGIN T NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T SE APARTMENT_LIGHTS_PLUGIN T SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T NE APARTMENT_LIGHTS_PLUGIN T NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T N1 APARTMENT_LIGHTS_PLUGIN T N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T N2 APARTMENT_LIGHTS_PLUGIN T N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T S1 APARTMENT_LIGHTS_PLUGIN T S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T S2 APARTMENT_LIGHTS_PLUGIN T S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
Interior Lighting Total   7.3426 14974.03 109947.72               416.41


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 10720.10 AstronomicalClock -   83.60 83.60 168.23
Exterior Lighting Total 10720.10           168.23



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:07

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
CENTRAL BOILER Boiler:HotWater 285703.90 0.80    
CENTRAL TOWER EvaporativeFluidCooler:SingleSpeed 228563.12      


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
HEAT PUMP COOLING MODE AIRLOOP G SW Coil:Cooling:WaterToAirHeatPump:EquationFit   3528.92 2377.71 1151.21 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3306.49 2210.54 1095.95 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP OFFICE Coil:Cooling:WaterToAirHeatPump:EquationFit   4854.57 3276.14 1578.42 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2565.01 1668.04 896.97 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1903.95 1196.19 707.76 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1879.98 1178.96 701.03 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2400.02 1547.85 852.17 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2472.34 1601.88 870.46 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4518.49 3092.88 1425.62 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4201.37 2854.19 1347.19 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4323.42 2939.96 1383.46 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3354.89 2233.43 1121.45 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2505.25 1623.71 881.55 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2485.64 1609.34 876.29 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3077.96 2039.27 1038.69 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3107.05 2061.10 1045.95 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4569.22 3114.12 1455.10 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4271.16 2890.19 1380.97 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4163.86 2803.94 1359.92 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3439.42 2281.73 1157.69 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2581.65 1672.02 909.64 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2562.25 1657.83 904.43 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3147.65 2082.24 1065.41 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3162.79 2093.61 1069.18 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4602.93 3126.94 1475.99 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4310.18 2907.33 1402.84 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4181.53 2805.32 1376.21 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3477.13 2298.90 1178.22 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2616.57 1691.79 924.78 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2597.23 1677.67 919.56 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3177.63 2097.80 1079.83 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3190.80 2107.68 1083.12 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4661.91 3161.05 1500.85 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4373.79 2945.15 1428.64 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4242.51 2841.33 1401.18 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3546.55 2340.28 1206.27 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2674.76 1729.73 945.03 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2655.49 1715.67 939.82 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3231.57 2132.49 1099.08 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3244.46 2142.16 1102.31 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4628.04 3127.23 1500.81 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4341.26 2912.67 1428.59 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4212.63 2811.02 1401.61 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3513.82 2308.77 1205.05 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2640.08 1700.31 939.77 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2620.90 1686.36 934.54 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3194.31 2100.05 1094.26 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3207.19 2109.69 1097.50 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4625.23 3117.77 1507.47 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4340.80 2905.22 1435.58 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4213.33 2804.58 1408.74 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3512.70 2301.67 1211.03 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2636.62 1694.34 942.28 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2617.51 1680.47 937.04 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3188.01 2091.31 1096.70 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3200.88 2100.94 1099.94 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4639.57 3121.92 1517.65 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4357.24 2911.15 1446.09 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4229.62 2810.53 1419.09 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3527.42 2306.98 1220.44 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2650.74 1701.59 949.15 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2631.74 1687.82 943.93 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3198.30 2095.35 1102.95 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3211.20 2104.99 1106.21 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4771.21 3214.06 1557.14 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4485.99 3001.09 1484.90 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4329.35 2878.35 1451.00 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3583.63 2343.21 1240.43 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2762.19 1780.06 982.14 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2742.96 1766.09 976.87 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3279.96 2152.19 1127.77 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3292.82 2161.81 1131.02 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5570.21 3802.02 1768.19 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5157.42 3496.95 1660.47 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SE Coil:Cooling:WaterToAirHeatPump:EquationFit   5126.16 3467.80 1658.37 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4216.68 2803.92 1412.75 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3212.28 2100.53 1111.75 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3214.81 2101.27 1113.53 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   4204.72 2839.89 1364.84 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   4217.84 2849.80 1368.04 0.68 0.00    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
None            


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
HEAT PUMP HEATING MODE AIRLOOP G SW Coil:Heating:WaterToAirHeatPump:EquationFit   3528.92 0.00
HEAT PUMP HEATING MODE AIRLOOP G NW Coil:Heating:WaterToAirHeatPump:EquationFit   3306.49 0.00
HEAT PUMP HEATING MODE AIRLOOP OFFICE Coil:Heating:WaterToAirHeatPump:EquationFit   4854.57 0.00
HEAT PUMP HEATING MODE AIRLOOP G NE Coil:Heating:WaterToAirHeatPump:EquationFit   2565.01 0.00
HEAT PUMP HEATING MODE AIRLOOP G N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1903.95 0.00
HEAT PUMP HEATING MODE AIRLOOP G N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1879.98 0.00
HEAT PUMP HEATING MODE AIRLOOP G S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2400.02 0.00
HEAT PUMP HEATING MODE AIRLOOP G S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2472.34 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4518.49 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4201.37 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4323.42 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3354.89 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2505.25 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2485.64 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3077.96 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3107.05 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4569.22 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4271.16 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4163.86 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3439.42 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2581.65 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2562.25 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3147.65 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3162.79 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4602.93 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4310.18 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4181.53 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3477.13 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2616.57 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2597.23 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3177.63 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3190.80 0.00
HEAT PUMP HEATING MODE AIRLOOP M SW Coil:Heating:WaterToAirHeatPump:EquationFit   4661.91 0.00
HEAT PUMP HEATING MODE AIRLOOP M NW Coil:Heating:WaterToAirHeatPump:EquationFit   4373.79 0.00
HEAT PUMP HEATING MODE AIRLOOP M SE Coil:Heating:WaterToAirHeatPump:EquationFit   4242.51 0.00
HEAT PUMP HEATING MODE AIRLOOP M NE Coil:Heating:WaterToAirHeatPump:EquationFit   3546.55 0.00
HEAT PUMP HEATING MODE AIRLOOP M N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2674.76 0.00
HEAT PUMP HEATING MODE AIRLOOP M N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2655.49 0.00
HEAT PUMP HEATING MODE AIRLOOP M S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3231.57 0.00
HEAT PUMP HEATING MODE AIRLOOP M S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3244.46 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4628.04 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4341.26 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4212.63 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3513.82 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2640.08 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2620.90 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3194.31 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3207.19 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4625.23 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4340.80 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4213.33 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3512.70 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2636.62 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2617.51 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3188.01 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3200.88 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4639.57 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4357.24 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4229.62 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3527.42 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2650.74 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2631.74 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3198.30 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3211.20 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4771.21 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4485.99 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4329.35 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3583.63 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2762.19 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2742.96 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3279.96 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3292.82 0.00
HEAT PUMP HEATING MODE AIRLOOP T SW Coil:Heating:WaterToAirHeatPump:EquationFit   5570.21 0.00
HEAT PUMP HEATING MODE AIRLOOP T NW Coil:Heating:WaterToAirHeatPump:EquationFit   5157.42 0.00
HEAT PUMP HEATING MODE AIRLOOP T SE Coil:Heating:WaterToAirHeatPump:EquationFit   5126.16 0.00
HEAT PUMP HEATING MODE AIRLOOP T NE Coil:Heating:WaterToAirHeatPump:EquationFit   4216.68 0.00
HEAT PUMP HEATING MODE AIRLOOP T N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3212.28 0.00
HEAT PUMP HEATING MODE AIRLOOP T N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3214.81 0.00
HEAT PUMP HEATING MODE AIRLOOP T S1 Coil:Heating:WaterToAirHeatPump:EquationFit   4204.72 0.00
HEAT PUMP HEATING MODE AIRLOOP T S2 Coil:Heating:WaterToAirHeatPump:EquationFit   4217.84 0.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW Coil:Heating:Electric   3875.68 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW Coil:Heating:Electric   3881.41 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE Coil:Heating:Electric   4864.18 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE Coil:Heating:Electric   3882.12 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 Coil:Heating:Electric   2939.41 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 Coil:Heating:Electric   2939.41 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 Coil:Heating:Electric   2930.57 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 Coil:Heating:Electric   2939.07 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW Coil:Heating:Electric   3896.08 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW Coil:Heating:Electric   3895.59 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE Coil:Heating:Electric   3917.02 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE Coil:Heating:Electric   3891.76 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 Coil:Heating:Electric   2724.90 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 Coil:Heating:Electric   2724.81 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 Coil:Heating:Electric   2728.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 Coil:Heating:Electric   2729.76 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW Coil:Heating:Electric   3958.78 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW Coil:Heating:Electric   3959.97 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE Coil:Heating:Electric   3954.60 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE Coil:Heating:Electric   3953.19 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 Coil:Heating:Electric   2724.73 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 Coil:Heating:Electric   2724.58 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 Coil:Heating:Electric   2724.43 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 Coil:Heating:Electric   2724.51 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW Coil:Heating:Electric   4061.22 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW Coil:Heating:Electric   4063.03 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE Coil:Heating:Electric   4052.63 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE Coil:Heating:Electric   4054.19 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 Coil:Heating:Electric   2776.51 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 Coil:Heating:Electric   2776.31 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 Coil:Heating:Electric   2775.29 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 Coil:Heating:Electric   2775.12 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW Coil:Heating:Electric   4130.63 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW Coil:Heating:Electric   4131.45 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE Coil:Heating:Electric   4120.25 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE Coil:Heating:Electric   4121.04 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 Coil:Heating:Electric   2804.23 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 Coil:Heating:Electric   2803.98 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 Coil:Heating:Electric   2803.93 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 Coil:Heating:Electric   2803.69 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW Coil:Heating:Electric   4259.15 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW Coil:Heating:Electric   4260.97 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE Coil:Heating:Electric   4247.48 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE Coil:Heating:Electric   4249.30 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 Coil:Heating:Electric   2897.38 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 Coil:Heating:Electric   2897.10 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 Coil:Heating:Electric   2896.07 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 Coil:Heating:Electric   2895.79 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW Coil:Heating:Electric   4353.54 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW Coil:Heating:Electric   4355.13 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE Coil:Heating:Electric   4340.83 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE Coil:Heating:Electric   4342.42 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 Coil:Heating:Electric   2960.61 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 Coil:Heating:Electric   2960.31 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 Coil:Heating:Electric   2959.55 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 Coil:Heating:Electric   2959.25 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW Coil:Heating:Electric   4449.52 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW Coil:Heating:Electric   4450.55 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE Coil:Heating:Electric   4435.91 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE Coil:Heating:Electric   4436.96 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 Coil:Heating:Electric   3028.55 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 Coil:Heating:Electric   3028.23 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 Coil:Heating:Electric   3028.04 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 Coil:Heating:Electric   3027.72 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW Coil:Heating:Electric   4687.48 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW Coil:Heating:Electric   4684.96 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE Coil:Heating:Electric   4672.98 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE Coil:Heating:Electric   4670.47 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 Coil:Heating:Electric   3228.12 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 Coil:Heating:Electric   3227.78 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 Coil:Heating:Electric   3230.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 Coil:Heating:Electric   3230.40 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW Coil:Heating:Electric   5454.99 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW Coil:Heating:Electric   5460.29 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE Coil:Heating:Electric   5440.98 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE Coil:Heating:Electric   5446.29 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 Coil:Heating:Electric   4048.30 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 Coil:Heating:Electric   4047.95 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 Coil:Heating:Electric   4040.26 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 Coil:Heating:Electric   4039.91 1.00


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
AIRLOOP G SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.21 231.20 1120.11 1.00 General
AIRLOOP G NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 213.79 1120.11 1.00 General
AIRLOOP OFFICE SUPPLY FAN Fan:OnOff 0.56 622.50 0.28 316.53 1120.11 1.00 General
AIRLOOP G NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 157.57 1120.11 1.00 General
AIRLOOP G N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.10 108.75 1120.11 1.00 General
AIRLOOP G N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.10 106.93 1120.11 1.00 General
AIRLOOP G S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.13 142.36 1120.11 1.00 General
AIRLOOP G S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.13 148.13 1120.11 1.00 General
AIRLOOP F2 SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 305.50 1120.11 1.00 General
AIRLOOP F2 NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.25 280.52 1120.11 1.00 General
AIRLOOP F2 SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 287.34 1120.11 1.00 General
AIRLOOP F2 NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 216.21 1120.11 1.00 General
AIRLOOP F2 N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 153.23 1120.11 1.00 General
AIRLOOP F2 N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 151.71 1120.11 1.00 General
AIRLOOP F2 S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.17 193.62 1120.11 1.00 General
AIRLOOP F2 S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.17 195.95 1120.11 1.00 General
AIRLOOP F3 SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 306.67 1120.11 1.00 General
AIRLOOP F3 NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.25 283.26 1120.11 1.00 General
AIRLOOP F3 SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.24 271.78 1120.11 1.00 General
AIRLOOP F3 NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.20 220.31 1120.11 1.00 General
AIRLOOP F3 N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 157.75 1120.11 1.00 General
AIRLOOP F3 N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 156.25 1120.11 1.00 General
AIRLOOP F3 S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 197.55 1120.11 1.00 General
AIRLOOP F3 S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 198.77 1120.11 1.00 General
AIRLOOP F4 SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 307.21 1120.11 1.00 General
AIRLOOP F4 NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.25 284.27 1120.11 1.00 General
AIRLOOP F4 SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.24 271.13 1120.11 1.00 General
AIRLOOP F4 NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.20 221.35 1120.11 1.00 General
AIRLOOP F4 N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 159.38 1120.11 1.00 General
AIRLOOP F4 N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 157.89 1120.11 1.00 General
AIRLOOP F4 S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 198.72 1120.11 1.00 General
AIRLOOP F4 S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 199.78 1120.11 1.00 General
AIRLOOP M SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.28 310.17 1120.11 1.00 General
AIRLOOP M NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 287.63 1120.11 1.00 General
AIRLOOP M SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.24 274.30 1120.11 1.00 General
AIRLOOP M NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.20 224.68 1120.11 1.00 General
AIRLOOP M N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.15 163.03 1120.11 1.00 General
AIRLOOP M N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 161.55 1120.11 1.00 General
AIRLOOP M S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 202.02 1120.11 1.00 General
AIRLOOP M S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 203.05 1120.11 1.00 General
AIRLOOP F6 SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 306.00 1120.11 1.00 General
AIRLOOP F6 NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.25 283.62 1120.11 1.00 General
AIRLOOP F6 SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.24 270.52 1120.11 1.00 General
AIRLOOP F6 NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.20 220.79 1120.11 1.00 General
AIRLOOP F6 N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 159.59 1120.11 1.00 General
AIRLOOP F6 N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 158.11 1120.11 1.00 General
AIRLOOP F6 S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 198.23 1120.11 1.00 General
AIRLOOP F6 S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 199.26 1120.11 1.00 General
AIRLOOP F7 SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 304.50 1120.11 1.00 General
AIRLOOP F7 NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.25 282.33 1120.11 1.00 General
AIRLOOP F7 SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.24 269.35 1120.11 1.00 General
AIRLOOP F7 NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.20 219.57 1120.11 1.00 General
AIRLOOP F7 N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 158.67 1120.11 1.00 General
AIRLOOP F7 N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 157.21 1120.11 1.00 General
AIRLOOP F7 S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 197.01 1120.11 1.00 General
AIRLOOP F7 S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 198.03 1120.11 1.00 General
AIRLOOP F8 SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 304.49 1120.11 1.00 General
AIRLOOP F8 NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.25 282.52 1120.11 1.00 General
AIRLOOP F8 SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.24 269.55 1120.11 1.00 General
AIRLOOP F8 NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.20 219.71 1120.11 1.00 General
AIRLOOP F8 N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 159.19 1120.11 1.00 General
AIRLOOP F8 N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 157.73 1120.11 1.00 General
AIRLOOP F8 S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 197.17 1120.11 1.00 General
AIRLOOP F8 S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 198.20 1120.11 1.00 General
AIRLOOP F9 SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.28 313.87 1120.11 1.00 General
AIRLOOP F9 NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 291.66 1120.11 1.00 General
AIRLOOP F9 SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.25 276.20 1120.11 1.00 General
AIRLOOP F9 NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.20 223.16 1120.11 1.00 General
AIRLOOP F9 N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.15 167.27 1120.11 1.00 General
AIRLOOP F9 N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.15 165.80 1120.11 1.00 General
AIRLOOP F9 S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 202.83 1120.11 1.00 General
AIRLOOP F9 S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 203.86 1120.11 1.00 General
AIRLOOP T SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.33 374.41 1120.11 1.00 General
AIRLOOP T NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.31 343.56 1120.11 1.00 General
AIRLOOP T SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.30 338.59 1120.11 1.00 General
AIRLOOP T NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.24 271.19 1120.11 1.00 General
AIRLOOP T N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 197.36 1120.11 1.00 General
AIRLOOP T N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 197.24 1120.11 1.00 General
AIRLOOP T S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.25 275.86 1120.11 1.00 General
AIRLOOP T S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.25 276.92 1120.11 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
SHWSYS1 PUMP Pump:ConstantSpeed Intermittent 29891.00 0.0003 36.93 127739.32 0.30
PLANT CIRC PUMP Pump:ConstantSpeed Intermittent 179045.11 0.0062 1584.95 255050.01 0.90


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
SHWSYS1 WATER HEATER WaterHeater:Mixed 2.27 175842.64 0.80 0.00 0.00



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:07

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 2141.20 2569.44 0.172 0.206 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 28.53 0.01335
G NW APARTMENT 1979.98 2375.98 0.159 0.191 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 28.07 0.01335
OFFICE 2931.49 3517.79 0.235 0.283 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 30.07 0.01335
G NE APARTMENT 1459.24 1751.09 0.117 0.141 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 27.11 0.01335
G N1 APARTMENT 1007.21 1208.65 0.081 0.097 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 26.67 0.01335
G N2 APARTMENT 990.32 1188.38 0.080 0.095 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 26.67 0.01335
G S1 APARTMENT 1318.43 1582.12 0.106 0.127 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 30.18 0.01335
G S2 APARTMENT 1371.86 1646.23 0.110 0.132 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 30.18 0.01335
F2 SW APARTMENT 2829.35 3395.22 0.227 0.273 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 28.53 0.01335
F2 NW APARTMENT 2597.93 3117.51 0.209 0.250 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 28.07 0.01335
F2 SE APARTMENT 2661.08 3193.30 0.214 0.257 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 30.07 0.01335
F2 NE APARTMENT 2002.33 2402.80 0.161 0.193 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 27.11 0.01335
F2 N1 APARTMENT 1419.15 1702.99 0.114 0.137 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 26.67 0.01335
F2 N2 APARTMENT 1405.06 1686.07 0.113 0.135 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 26.67 0.01335
F2 S1 APARTMENT 1793.20 2151.84 0.144 0.173 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 30.18 0.01335
F2 S2 APARTMENT 1814.76 2177.71 0.146 0.175 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 30.18 0.01335
F3 SW APARTMENT 2840.08 3408.09 0.228 0.274 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 28.53 0.01335
F3 NW APARTMENT 2623.32 3147.98 0.211 0.253 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 28.07 0.01335
F3 SE APARTMENT 2516.96 3020.35 0.202 0.243 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 30.07 0.01335
F3 NE APARTMENT 2040.22 2448.27 0.164 0.197 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 27.11 0.01335
F3 N1 APARTMENT 1460.95 1753.14 0.117 0.141 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 26.67 0.01335
F3 N2 APARTMENT 1447.03 1736.43 0.116 0.139 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 26.67 0.01335
F3 S1 APARTMENT 1829.58 2195.49 0.147 0.176 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 30.18 0.01335
F3 S2 APARTMENT 1840.82 2208.98 0.148 0.177 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 30.18 0.01335
F4 SW APARTMENT 2845.08 3414.10 0.229 0.274 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 28.53 0.01335
F4 NW APARTMENT 2632.65 3159.18 0.211 0.254 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 28.07 0.01335
F4 SE APARTMENT 2510.85 3013.01 0.202 0.242 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 30.07 0.01335
F4 NE APARTMENT 2049.86 2459.83 0.165 0.198 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 27.11 0.01335
F4 N1 APARTMENT 1476.08 1771.29 0.119 0.142 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 26.67 0.01335
F4 N2 APARTMENT 1462.23 1754.68 0.117 0.141 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 26.67 0.01335
F4 S1 APARTMENT 1840.40 2208.49 0.148 0.177 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 30.18 0.01335
F4 S2 APARTMENT 1850.18 2220.21 0.149 0.178 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 30.18 0.01335
M SW APARTMENT 2872.46 3446.96 0.231 0.277 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 28.53 0.01335
M NW APARTMENT 2663.75 3196.50 0.214 0.257 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 28.07 0.01335
M SE APARTMENT 2540.20 3048.25 0.204 0.245 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 30.07 0.01335
M NE APARTMENT 2080.64 2496.76 0.167 0.201 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 27.46 0.01335
M N1 APARTMENT 1509.88 1811.86 0.121 0.146 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 26.67 0.01335
M N2 APARTMENT 1496.10 1795.33 0.120 0.144 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 26.67 0.01335
M S1 APARTMENT 1870.91 2245.09 0.150 0.180 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 30.18 0.01335
M S2 APARTMENT 1880.47 2256.56 0.151 0.181 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 30.18 0.01335
F6 SW APARTMENT 2833.86 3400.64 0.228 0.273 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 28.53 0.01335
F6 NW APARTMENT 2626.53 3151.83 0.211 0.253 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 28.07 0.01335
F6 SE APARTMENT 2505.21 3006.26 0.201 0.242 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 30.07 0.01335
F6 NE APARTMENT 2044.62 2453.54 0.164 0.197 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 27.46 0.01335
F6 N1 APARTMENT 1477.94 1773.53 0.119 0.142 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 26.67 0.01335
F6 N2 APARTMENT 1464.29 1757.14 0.118 0.141 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 26.67 0.01335
F6 S1 APARTMENT 1835.83 2203.00 0.147 0.177 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 30.18 0.01335
F6 S2 APARTMENT 1845.36 2214.44 0.148 0.178 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 30.18 0.01335
F7 SW APARTMENT 2819.91 3383.89 0.227 0.272 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 28.53 0.01335
F7 NW APARTMENT 2614.62 3137.54 0.210 0.252 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 28.07 0.01335
F7 SE APARTMENT 2494.36 2993.23 0.200 0.240 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 30.07 0.01335
F7 NE APARTMENT 2033.27 2439.93 0.163 0.196 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 27.46 0.01335
F7 N1 APARTMENT 1469.46 1763.35 0.118 0.142 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 26.67 0.01335
F7 N2 APARTMENT 1455.89 1747.07 0.117 0.140 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 26.67 0.01335
F7 S1 APARTMENT 1824.48 2189.38 0.147 0.176 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 30.18 0.01335
F7 S2 APARTMENT 1834.00 2200.80 0.147 0.177 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 30.18 0.01335
F8 SW APARTMENT 2819.84 3383.81 0.227 0.272 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 28.53 0.01335
F8 NW APARTMENT 2616.35 3139.62 0.210 0.252 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 28.07 0.01335
F8 SE APARTMENT 2496.16 2995.39 0.201 0.241 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 30.07 0.01335
F8 NE APARTMENT 2034.59 2441.51 0.163 0.196 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 27.46 0.01335
F8 N1 APARTMENT 1474.24 1769.09 0.118 0.142 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 26.67 0.01335
F8 N2 APARTMENT 1460.78 1752.93 0.117 0.141 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 26.67 0.01335
F8 S1 APARTMENT 1826.01 2191.21 0.147 0.176 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 30.18 0.01335
F8 S2 APARTMENT 1835.54 2202.65 0.147 0.177 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 30.18 0.01335
F9 SW APARTMENT 2906.67 3488.00 0.234 0.280 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 28.53 0.01335
F9 NW APARTMENT 2701.02 3241.22 0.217 0.260 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 28.07 0.01335
F9 SE APARTMENT 2557.69 3069.23 0.205 0.247 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 30.18 0.01335
F9 NE APARTMENT 2066.52 2479.82 0.166 0.199 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 27.46 0.01335
F9 N1 APARTMENT 1549.10 1858.92 0.124 0.149 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 26.67 0.01335
F9 N2 APARTMENT 1535.45 1842.54 0.123 0.148 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 26.67 0.01335
F9 S1 APARTMENT 1878.43 2254.11 0.151 0.181 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 30.30 0.01335
F9 S2 APARTMENT 1887.93 2265.52 0.152 0.182 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 30.30 0.01335
T SW APARTMENT 3467.07 4160.48 0.279 0.334 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:45:00 29.88 0.01335
T NW APARTMENT 3181.54 3817.85 0.256 0.307 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 28.53 0.01335
T SE APARTMENT 3135.38 3762.46 0.252 0.302 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 30.07 0.01335
T NE APARTMENT 2511.22 3013.47 0.202 0.242 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:45:00 27.81 0.01335
T N1 APARTMENT 1827.72 2193.26 0.147 0.176 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:15:00 30.16 0.01335
T N2 APARTMENT 1826.58 2191.90 0.147 0.176 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 14:45:00 30.30 0.01335
T S1 APARTMENT 2554.67 3065.61 0.205 0.246 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 30.18 0.01335
T S2 APARTMENT 2564.50 3077.40 0.206 0.247 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 30.18 0.01335


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 2293.72 2752.46 0.105 0.126 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -16.30 0.00092
G NW APARTMENT 2298.56 2758.27 0.105 0.126 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -16.30 0.00092
OFFICE 2669.06 3202.87 0.122 0.146 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 18:45:00 -16.30 0.00092
G NE APARTMENT 2299.16 2759.00 0.105 0.126 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -16.30 0.00092
G N1 APARTMENT 1501.95 1802.34 0.069 0.082 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -16.30 0.00092
G N2 APARTMENT 1501.95 1802.34 0.069 0.082 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -16.30 0.00092
G S1 APARTMENT 1494.47 1793.37 0.068 0.082 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -16.30 0.00092
G S2 APARTMENT 1501.66 1801.99 0.069 0.082 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -16.30 0.00092
F2 SW APARTMENT 2311.01 2773.21 0.105 0.127 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F2 NW APARTMENT 2310.60 2772.72 0.105 0.127 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F2 SE APARTMENT 2328.72 2794.46 0.106 0.128 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F2 NE APARTMENT 2307.36 2768.83 0.105 0.126 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F2 N1 APARTMENT 1320.57 1584.69 0.060 0.072 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F2 N2 APARTMENT 1320.50 1584.60 0.060 0.072 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F2 S1 APARTMENT 1323.43 1588.12 0.060 0.072 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F2 S2 APARTMENT 1324.69 1589.62 0.060 0.073 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F3 SW APARTMENT 2364.04 2836.85 0.108 0.129 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F3 NW APARTMENT 2365.05 2838.06 0.108 0.130 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F3 SE APARTMENT 2360.51 2832.61 0.108 0.129 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F3 NE APARTMENT 2359.31 2831.18 0.108 0.129 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F3 N1 APARTMENT 1320.44 1584.53 0.060 0.072 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F3 N2 APARTMENT 1320.31 1584.37 0.060 0.072 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F3 S1 APARTMENT 1320.19 1584.23 0.060 0.072 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F3 S2 APARTMENT 1320.25 1584.31 0.060 0.072 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F4 SW APARTMENT 2450.68 2940.82 0.112 0.134 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F4 NW APARTMENT 2452.21 2942.66 0.112 0.134 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F4 SE APARTMENT 2443.42 2932.10 0.112 0.134 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F4 NE APARTMENT 2444.73 2933.68 0.112 0.134 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F4 N1 APARTMENT 1364.24 1637.08 0.062 0.075 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F4 N2 APARTMENT 1364.06 1636.87 0.062 0.075 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F4 S1 APARTMENT 1363.20 1635.84 0.062 0.075 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F4 S2 APARTMENT 1363.05 1635.66 0.062 0.075 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
M SW APARTMENT 2509.39 3011.27 0.115 0.137 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
M NW APARTMENT 2510.07 3012.09 0.115 0.137 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
M SE APARTMENT 2500.61 3000.73 0.114 0.137 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
M NE APARTMENT 2501.27 3001.53 0.114 0.137 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
M N1 APARTMENT 1387.68 1665.21 0.063 0.076 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
M N2 APARTMENT 1387.47 1664.96 0.063 0.076 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
M S1 APARTMENT 1387.43 1664.91 0.063 0.076 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
M S2 APARTMENT 1387.22 1664.67 0.063 0.076 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F6 SW APARTMENT 2618.07 3141.68 0.119 0.143 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F6 NW APARTMENT 2619.62 3143.54 0.120 0.143 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F6 SE APARTMENT 2608.20 3129.84 0.119 0.143 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F6 NE APARTMENT 2609.75 3131.70 0.119 0.143 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F6 N1 APARTMENT 1466.45 1759.74 0.067 0.080 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F6 N2 APARTMENT 1466.22 1759.46 0.067 0.080 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F6 S1 APARTMENT 1465.34 1758.41 0.067 0.080 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F6 S2 APARTMENT 1465.11 1758.13 0.067 0.080 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F7 SW APARTMENT 2697.90 3237.48 0.123 0.148 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F7 NW APARTMENT 2699.25 3239.10 0.123 0.148 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F7 SE APARTMENT 2687.15 3224.58 0.123 0.147 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F7 NE APARTMENT 2688.50 3226.20 0.123 0.147 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F7 N1 APARTMENT 1519.93 1823.91 0.069 0.083 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F7 N2 APARTMENT 1519.67 1823.61 0.069 0.083 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F7 S1 APARTMENT 1519.03 1822.84 0.069 0.083 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F7 S2 APARTMENT 1518.78 1822.53 0.069 0.083 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F8 SW APARTMENT 2779.07 3334.88 0.127 0.152 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F8 NW APARTMENT 2779.94 3335.93 0.127 0.152 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F8 SE APARTMENT 2767.56 3321.08 0.126 0.152 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F8 NE APARTMENT 2768.44 3322.13 0.126 0.152 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F8 N1 APARTMENT 1577.38 1892.86 0.072 0.086 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F8 N2 APARTMENT 1577.11 1892.54 0.072 0.086 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F8 S1 APARTMENT 1576.95 1892.34 0.072 0.086 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F8 S2 APARTMENT 1576.68 1892.02 0.072 0.086 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F9 SW APARTMENT 2980.31 3576.37 0.136 0.163 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F9 NW APARTMENT 2978.18 3573.81 0.136 0.163 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F9 SE APARTMENT 2968.04 3561.65 0.135 0.163 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F9 NE APARTMENT 2965.92 3559.10 0.135 0.162 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F9 N1 APARTMENT 1746.15 2095.38 0.080 0.096 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F9 N2 APARTMENT 1745.86 2095.04 0.080 0.096 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F9 S1 APARTMENT 1748.37 2098.05 0.080 0.096 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
F9 S2 APARTMENT 1748.09 2097.70 0.080 0.096 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
T SW APARTMENT 3629.36 4355.23 0.166 0.199 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
T NW APARTMENT 3633.85 4360.62 0.166 0.199 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
T SE APARTMENT 3617.52 4341.02 0.165 0.198 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
T NE APARTMENT 3622.00 4346.40 0.165 0.198 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
T N1 APARTMENT 2439.75 2927.70 0.111 0.134 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
T N2 APARTMENT 2439.45 2927.34 0.111 0.134 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
T S1 APARTMENT 2432.94 2919.53 0.111 0.133 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092
T S2 APARTMENT 2432.65 2919.18 0.111 0.133 BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -16.30 0.00092


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
AIRLOOP G SW 0.21 0.21 0.13 0.13
AIRLOOP G NW 0.19 0.19 0.13 0.13
AIRLOOP OFFICE 0.28 0.28 0.15 0.15
AIRLOOP G NE 0.14 0.14 0.13 0.13
AIRLOOP G N1 0.10 0.10 0.08 0.08
AIRLOOP G N2 0.10 0.10 0.08 0.08
AIRLOOP G S1 0.13 0.13 0.08 0.08
AIRLOOP G S2 0.13 0.13 0.08 0.08
AIRLOOP F2 SW 0.27 0.27 0.13 0.13
AIRLOOP F2 NW 0.25 0.25 0.13 0.13
AIRLOOP F2 SE 0.26 0.26 0.13 0.13
AIRLOOP F2 NE 0.19 0.19 0.13 0.13
AIRLOOP F2 N1 0.14 0.14 0.07 0.07
AIRLOOP F2 N2 0.14 0.14 0.07 0.07
AIRLOOP F2 S1 0.17 0.17 0.07 0.07
AIRLOOP F2 S2 0.17 0.17 0.07 0.07
AIRLOOP F3 SW 0.27 0.27 0.13 0.13
AIRLOOP F3 NW 0.25 0.25 0.13 0.13
AIRLOOP F3 SE 0.24 0.24 0.13 0.13
AIRLOOP F3 NE 0.20 0.20 0.13 0.13
AIRLOOP F3 N1 0.14 0.14 0.07 0.07
AIRLOOP F3 N2 0.14 0.14 0.07 0.07
AIRLOOP F3 S1 0.18 0.18 0.07 0.07
AIRLOOP F3 S2 0.18 0.18 0.07 0.07
AIRLOOP F4 SW 0.27 0.27 0.13 0.13
AIRLOOP F4 NW 0.25 0.25 0.13 0.13
AIRLOOP F4 SE 0.24 0.24 0.13 0.13
AIRLOOP F4 NE 0.20 0.20 0.13 0.13
AIRLOOP F4 N1 0.14 0.14 0.07 0.07
AIRLOOP F4 N2 0.14 0.14 0.07 0.07
AIRLOOP F4 S1 0.18 0.18 0.07 0.07
AIRLOOP F4 S2 0.18 0.18 0.07 0.07
AIRLOOP M SW 0.28 0.28 0.14 0.14
AIRLOOP M NW 0.26 0.26 0.14 0.14
AIRLOOP M SE 0.24 0.24 0.14 0.14
AIRLOOP M NE 0.20 0.20 0.14 0.14
AIRLOOP M N1 0.15 0.15 0.08 0.08
AIRLOOP M N2 0.14 0.14 0.08 0.08
AIRLOOP M S1 0.18 0.18 0.08 0.08
AIRLOOP M S2 0.18 0.18 0.08 0.08
AIRLOOP F6 SW 0.27 0.27 0.14 0.14
AIRLOOP F6 NW 0.25 0.25 0.14 0.14
AIRLOOP F6 SE 0.24 0.24 0.14 0.14
AIRLOOP F6 NE 0.20 0.20 0.14 0.14
AIRLOOP F6 N1 0.14 0.14 0.08 0.08
AIRLOOP F6 N2 0.14 0.14 0.08 0.08
AIRLOOP F6 S1 0.18 0.18 0.08 0.08
AIRLOOP F6 S2 0.18 0.18 0.08 0.08
AIRLOOP F7 SW 0.27 0.27 0.15 0.15
AIRLOOP F7 NW 0.25 0.25 0.15 0.15
AIRLOOP F7 SE 0.24 0.24 0.15 0.15
AIRLOOP F7 NE 0.20 0.20 0.15 0.15
AIRLOOP F7 N1 0.14 0.14 0.08 0.08
AIRLOOP F7 N2 0.14 0.14 0.08 0.08
AIRLOOP F7 S1 0.18 0.18 0.08 0.08
AIRLOOP F7 S2 0.18 0.18 0.08 0.08
AIRLOOP F8 SW 0.27 0.27 0.15 0.15
AIRLOOP F8 NW 0.25 0.25 0.15 0.15
AIRLOOP F8 SE 0.24 0.24 0.15 0.15
AIRLOOP F8 NE 0.20 0.20 0.15 0.15
AIRLOOP F8 N1 0.14 0.14 0.09 0.09
AIRLOOP F8 N2 0.14 0.14 0.09 0.09
AIRLOOP F8 S1 0.18 0.18 0.09 0.09
AIRLOOP F8 S2 0.18 0.18 0.09 0.09
AIRLOOP F9 SW 0.28 0.28 0.16 0.16
AIRLOOP F9 NW 0.26 0.26 0.16 0.16
AIRLOOP F9 SE 0.25 0.25 0.16 0.16
AIRLOOP F9 NE 0.20 0.20 0.16 0.16
AIRLOOP F9 N1 0.15 0.15 0.10 0.10
AIRLOOP F9 N2 0.15 0.15 0.10 0.10
AIRLOOP F9 S1 0.18 0.18 0.10 0.10
AIRLOOP F9 S2 0.18 0.18 0.10 0.10
AIRLOOP T SW 0.33 0.33 0.20 0.20
AIRLOOP T NW 0.31 0.31 0.20 0.20
AIRLOOP T SE 0.30 0.30 0.20 0.20
AIRLOOP T NE 0.24 0.24 0.20 0.20
AIRLOOP T N1 0.18 0.18 0.13 0.13
AIRLOOP T N2 0.18 0.18 0.13 0.13
AIRLOOP T S1 0.25 0.25 0.13 0.13
AIRLOOP T S2 0.25 0.25 0.13 0.13



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:07

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 3012.50 6582.50 1413.75
G NW APARTMENT 3180.75 6999.75 1902.50
OFFICE 899.75 1201.75 109.25
G NE APARTMENT 3177.25 7066.50 1893.50
G N1 APARTMENT 2368.50 7263.75 1315.75
G N2 APARTMENT 2365.25 7270.00 1316.25
G S1 APARTMENT 2405.25 6744.25 974.75
G S2 APARTMENT 2424.00 6701.00 962.25
F2 SW APARTMENT 3223.25 5447.75 813.75
F2 NW APARTMENT 3096.25 6143.50 1183.00
F2 SE APARTMENT 3309.50 5301.50 760.50
F2 NE APARTMENT 3025.25 6233.50 1171.75
F2 N1 APARTMENT 2382.50 6482.50 710.25
F2 N2 APARTMENT 2374.50 6488.50 709.75
F2 S1 APARTMENT 2795.25 5524.00 526.50
F2 S2 APARTMENT 2811.25 5495.50 524.00
F3 SW APARTMENT 3339.25 5290.25 792.00
F3 NW APARTMENT 3145.50 5990.00 1136.00
F3 SE APARTMENT 3354.75 5282.75 777.00
F3 NE APARTMENT 3083.50 6044.00 1114.25
F3 N1 APARTMENT 2468.75 6233.25 652.00
F3 N2 APARTMENT 2465.25 6241.75 652.25
F3 S1 APARTMENT 2969.50 5248.75 497.50
F3 S2 APARTMENT 2977.00 5242.25 497.25
F4 SW APARTMENT 3398.25 5275.50 809.00
F4 NW APARTMENT 3198.75 5947.25 1166.50
F4 SE APARTMENT 3387.75 5294.25 802.50
F4 NE APARTMENT 3135.75 5983.00 1139.50
F4 N1 APARTMENT 2520.00 6124.50 652.00
F4 N2 APARTMENT 2514.25 6138.50 652.75
F4 S1 APARTMENT 3040.25 5176.25 500.25
F4 S2 APARTMENT 3045.00 5174.00 501.00
M SW APARTMENT 3395.75 5299.75 808.25
M NW APARTMENT 3187.25 5945.25 1150.00
M SE APARTMENT 3374.25 5319.25 802.00
M NE APARTMENT 3129.50 5974.75 1123.75
M N1 APARTMENT 2531.50 6084.00 634.75
M N2 APARTMENT 2529.50 6097.00 636.50
M S1 APARTMENT 3041.75 5168.25 494.75
M S2 APARTMENT 3044.75 5166.00 494.50
F6 SW APARTMENT 3302.50 5467.25 881.25
F6 NW APARTMENT 3194.00 6116.75 1268.00
F6 SE APARTMENT 3287.00 5476.25 871.25
F6 NE APARTMENT 3123.25 6158.25 1239.50
F6 N1 APARTMENT 2471.25 6270.75 693.50
F6 N2 APARTMENT 2467.25 6283.25 694.00
F6 S1 APARTMENT 2924.00 5329.25 526.50
F6 S2 APARTMENT 2924.75 5329.50 526.00
F7 SW APARTMENT 3244.00 5573.50 921.25
F7 NW APARTMENT 3181.50 6225.50 1328.00
F7 SE APARTMENT 3246.75 5584.00 914.00
F7 NE APARTMENT 3119.50 6289.00 1304.25
F7 N1 APARTMENT 2427.50 6387.00 725.25
F7 N2 APARTMENT 2425.00 6399.00 726.75
F7 S1 APARTMENT 2855.00 5462.75 547.75
F7 S2 APARTMENT 2855.50 5458.75 546.75
F8 SW APARTMENT 3198.75 5674.25 959.75
F8 NW APARTMENT 3192.50 6316.75 1396.25
F8 SE APARTMENT 3214.75 5685.75 954.00
F8 NE APARTMENT 3129.50 6387.00 1368.25
F8 N1 APARTMENT 2401.75 6486.25 763.50
F8 N2 APARTMENT 2397.00 6497.75 765.25
F8 S1 APARTMENT 2805.50 5584.75 572.50
F8 S2 APARTMENT 2808.25 5582.00 571.50
F9 SW APARTMENT 3236.00 5799.25 1086.25
F9 NW APARTMENT 3287.75 6400.00 1542.75
F9 SE APARTMENT 3246.50 5818.25 1074.25
F9 NE APARTMENT 3230.00 6487.50 1518.25
F9 N1 APARTMENT 2453.75 6598.50 869.75
F9 N2 APARTMENT 2449.75 6606.25 869.75
F9 S1 APARTMENT 2761.75 5742.75 641.25
F9 S2 APARTMENT 2767.00 5738.50 639.50
T SW APARTMENT 3956.50 6148.75 2055.00
T NW APARTMENT 4004.75 6663.50 2450.25
T SE APARTMENT 4005.25 6173.25 2054.75
T NE APARTMENT 4004.00 6684.00 2446.25
T N1 APARTMENT 3249.00 6785.25 1810.75
T N2 APARTMENT 3243.75 6792.75 1809.50
T S1 APARTMENT 3300.75 6056.50 1382.50
T S2 APARTMENT 3309.00 6050.50 1382.75
G CORRIDOR 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00
Facility 5370.25 7431.50 2723.25
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 3.25 2.75 3.25 2.75
G NW APARTMENT 4.00 3.25 4.00 3.25
OFFICE 2.75 0.00 0.50 0.00
G NE APARTMENT 5.00 7.00 5.00 7.00
G N1 APARTMENT 2.50 12.75 2.50 12.75
G N2 APARTMENT 2.50 14.50 2.50 14.50
G S1 APARTMENT 1.50 3.00 1.50 3.00
G S2 APARTMENT 3.25 2.25 3.25 2.25
F2 SW APARTMENT 0.75 3.50 0.75 3.50
F2 NW APARTMENT 1.00 4.00 1.00 4.00
F2 SE APARTMENT 2.75 1.50 2.75 1.50
F2 NE APARTMENT 3.50 8.50 3.50 8.50
F2 N1 APARTMENT 3.00 15.50 3.00 15.50
F2 N2 APARTMENT 2.00 18.25 2.00 18.25
F2 S1 APARTMENT 2.75 4.00 2.75 4.00
F2 S2 APARTMENT 3.50 4.00 3.50 4.00
F3 SW APARTMENT 0.75 4.50 0.75 4.50
F3 NW APARTMENT 1.75 4.25 1.75 4.25
F3 SE APARTMENT 3.00 6.00 3.00 6.00
F3 NE APARTMENT 2.50 17.00 2.50 17.00
F3 N1 APARTMENT 3.50 39.25 3.50 39.25
F3 N2 APARTMENT 3.50 42.00 3.50 42.00
F3 S1 APARTMENT 2.00 16.75 2.00 16.75
F3 S2 APARTMENT 3.25 15.50 3.25 15.50
F4 SW APARTMENT 1.75 4.75 1.75 4.75
F4 NW APARTMENT 1.50 4.50 1.50 4.50
F4 SE APARTMENT 2.00 7.25 2.00 7.25
F4 NE APARTMENT 2.25 20.75 2.25 20.75
F4 N1 APARTMENT 2.50 45.25 2.50 45.25
F4 N2 APARTMENT 2.75 47.25 2.75 47.25
F4 S1 APARTMENT 3.25 22.50 3.25 22.50
F4 S2 APARTMENT 1.75 22.50 1.75 22.50
M SW APARTMENT 0.50 6.00 0.50 6.00
M NW APARTMENT 0.25 5.50 0.25 5.50
M SE APARTMENT 0.75 8.00 0.75 8.00
M NE APARTMENT 2.25 23.75 2.25 23.75
M N1 APARTMENT 3.00 49.50 3.00 49.50
M N2 APARTMENT 3.25 52.50 3.25 52.50
M S1 APARTMENT 2.75 27.00 2.75 27.00
M S2 APARTMENT 3.00 24.50 3.00 24.50
F6 SW APARTMENT 1.50 6.25 1.50 6.25
F6 NW APARTMENT 0.00 6.00 0.00 6.00
F6 SE APARTMENT 2.00 9.00 2.00 9.00
F6 NE APARTMENT 2.25 26.00 2.25 26.00
F6 N1 APARTMENT 3.75 51.00 3.75 51.00
F6 N2 APARTMENT 4.25 54.25 4.25 54.25
F6 S1 APARTMENT 3.25 29.50 3.25 29.50
F6 S2 APARTMENT 3.50 28.00 3.50 28.00
F7 SW APARTMENT 1.00 6.75 1.00 6.75
F7 NW APARTMENT 0.25 6.50 0.25 6.50
F7 SE APARTMENT 0.75 10.25 0.75 10.25
F7 NE APARTMENT 3.75 27.75 3.75 27.75
F7 N1 APARTMENT 2.75 52.25 2.75 52.25
F7 N2 APARTMENT 4.25 54.75 4.25 54.75
F7 S1 APARTMENT 4.75 30.50 4.75 30.50
F7 S2 APARTMENT 3.00 29.50 3.00 29.50
F8 SW APARTMENT 0.25 8.00 0.25 8.00
F8 NW APARTMENT 0.00 7.50 0.00 7.50
F8 SE APARTMENT 1.00 12.00 1.00 12.00
F8 NE APARTMENT 1.00 31.25 1.00 31.25
F8 N1 APARTMENT 4.00 54.25 4.00 54.25
F8 N2 APARTMENT 3.25 55.00 3.25 55.00
F8 S1 APARTMENT 3.75 33.50 3.75 33.50
F8 S2 APARTMENT 3.25 31.75 3.25 31.75
F9 SW APARTMENT 0.25 8.75 0.25 8.75
F9 NW APARTMENT 0.25 8.25 0.25 8.25
F9 SE APARTMENT 1.75 12.50 1.75 12.50
F9 NE APARTMENT 0.75 34.25 0.75 34.25
F9 N1 APARTMENT 3.50 52.50 3.50 52.50
F9 N2 APARTMENT 3.25 54.25 3.25 54.25
F9 S1 APARTMENT 4.25 36.00 4.25 36.00
F9 S2 APARTMENT 4.25 33.75 4.25 33.75
T SW APARTMENT 0.25 4.75 0.25 4.75
T NW APARTMENT 0.00 6.00 0.00 6.00
T SE APARTMENT 0.00 8.00 0.00 8.00
T NE APARTMENT 0.25 28.00 0.25 28.00
T N1 APARTMENT 3.75 52.25 3.75 52.25
T N2 APARTMENT 4.25 51.50 4.25 51.50
T S1 APARTMENT 3.25 12.75 3.25 12.75
T S2 APARTMENT 3.25 12.25 3.25 12.25
G CORRIDOR 0.00 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
Facility 141.00 79.75 139.25 79.75
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:07

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.354 0.133 0.000 0.340
G NW APARTMENT 1.71 2.50 268.96 0.354 0.133 0.000 0.331
OFFICE 0.94 1.00 268.96 0.519 0.149 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.354 0.133 0.000 0.331
G N1 APARTMENT 1.71 2.50 268.96 0.354 0.080 0.000 0.326
G N2 APARTMENT 1.71 2.50 268.97 0.354 0.080 0.000 0.326
G S1 APARTMENT 1.71 2.50 268.96 0.354 0.080 0.000 0.337
G S2 APARTMENT 1.71 2.50 268.97 0.354 0.080 0.000 0.338
F2 SW APARTMENT 1.71 2.50 268.96 0.354 0.191 0.000 0.411
F2 NW APARTMENT 1.71 2.50 268.96 0.354 0.191 0.000 0.399
F2 SE APARTMENT 1.71 2.50 268.96 0.354 0.191 0.000 0.412
F2 NE APARTMENT 1.71 2.50 268.96 0.354 0.191 0.000 0.399
F2 N1 APARTMENT 1.71 2.50 268.96 0.354 0.115 0.000 0.395
F2 N2 APARTMENT 1.71 2.50 268.97 0.354 0.115 0.000 0.395
F2 S1 APARTMENT 1.71 2.50 268.96 0.354 0.115 0.000 0.409
F2 S2 APARTMENT 1.71 2.50 268.97 0.354 0.115 0.000 0.409
F3 SW APARTMENT 1.71 2.50 268.96 0.354 0.226 0.000 0.458
F3 NW APARTMENT 1.71 2.50 268.96 0.354 0.226 0.000 0.445
F3 SE APARTMENT 1.71 2.50 268.96 0.354 0.226 0.000 0.459
F3 NE APARTMENT 1.71 2.50 268.96 0.354 0.226 0.000 0.445
F3 N1 APARTMENT 1.71 2.50 268.96 0.354 0.136 0.000 0.441
F3 N2 APARTMENT 1.71 2.50 268.97 0.354 0.136 0.000 0.441
F3 S1 APARTMENT 1.71 2.50 268.96 0.354 0.136 0.000 0.456
F3 S2 APARTMENT 1.71 2.50 268.97 0.354 0.136 0.000 0.456
F4 SW APARTMENT 1.71 2.50 268.96 0.354 0.252 0.000 0.478
F4 NW APARTMENT 1.71 2.50 268.96 0.354 0.252 0.000 0.464
F4 SE APARTMENT 1.71 2.50 268.96 0.354 0.252 0.000 0.478
F4 NE APARTMENT 1.71 2.50 268.96 0.354 0.252 0.000 0.464
F4 N1 APARTMENT 1.71 2.50 268.96 0.354 0.152 0.000 0.461
F4 N2 APARTMENT 1.71 2.50 268.97 0.354 0.152 0.000 0.461
F4 S1 APARTMENT 1.71 2.50 268.96 0.354 0.152 0.000 0.476
F4 S2 APARTMENT 1.71 2.50 268.97 0.354 0.152 0.000 0.476
M SW APARTMENT 1.71 2.50 268.96 0.354 0.274 0.000 0.505
M NW APARTMENT 1.71 2.50 268.96 0.354 0.274 0.000 0.490
M SE APARTMENT 1.71 2.50 268.96 0.354 0.274 0.000 0.505
M NE APARTMENT 1.71 2.50 268.96 0.354 0.274 0.000 0.490
M N1 APARTMENT 1.71 2.50 268.96 0.354 0.165 0.000 0.487
M N2 APARTMENT 1.71 2.50 268.97 0.354 0.165 0.000 0.487
M S1 APARTMENT 1.71 2.50 268.96 0.354 0.165 0.000 0.504
M S2 APARTMENT 1.71 2.50 268.97 0.354 0.165 0.000 0.504
F6 SW APARTMENT 1.71 2.50 268.96 0.354 0.293 0.000 0.528
F6 NW APARTMENT 1.71 2.50 268.96 0.354 0.293 0.000 0.512
F6 SE APARTMENT 1.71 2.50 268.96 0.354 0.293 0.000 0.529
F6 NE APARTMENT 1.71 2.50 268.96 0.354 0.293 0.000 0.512
F6 N1 APARTMENT 1.71 2.50 268.96 0.354 0.177 0.000 0.509
F6 N2 APARTMENT 1.71 2.50 268.97 0.354 0.177 0.000 0.509
F6 S1 APARTMENT 1.71 2.50 268.96 0.354 0.177 0.000 0.527
F6 S2 APARTMENT 1.71 2.50 268.97 0.354 0.177 0.000 0.527
F7 SW APARTMENT 1.71 2.50 268.96 0.354 0.309 0.000 0.548
F7 NW APARTMENT 1.71 2.50 268.96 0.353 0.309 0.000 0.531
F7 SE APARTMENT 1.71 2.50 268.96 0.354 0.309 0.000 0.549
F7 NE APARTMENT 1.71 2.50 268.96 0.353 0.309 0.000 0.531
F7 N1 APARTMENT 1.71 2.50 268.96 0.354 0.187 0.000 0.528
F7 N2 APARTMENT 1.71 2.50 268.97 0.354 0.187 0.000 0.528
F7 S1 APARTMENT 1.71 2.50 268.96 0.354 0.187 0.000 0.547
F7 S2 APARTMENT 1.71 2.50 268.97 0.354 0.187 0.000 0.547
F8 SW APARTMENT 1.71 2.50 268.96 0.354 0.324 0.000 0.568
F8 NW APARTMENT 1.71 2.50 268.96 0.353 0.324 0.000 0.550
F8 SE APARTMENT 1.71 2.50 268.96 0.354 0.324 0.000 0.569
F8 NE APARTMENT 1.71 2.50 268.96 0.353 0.324 0.000 0.550
F8 N1 APARTMENT 1.71 2.50 268.96 0.354 0.196 0.000 0.547
F8 N2 APARTMENT 1.71 2.50 268.97 0.354 0.196 0.000 0.547
F8 S1 APARTMENT 1.71 2.50 268.96 0.354 0.196 0.000 0.567
F8 S2 APARTMENT 1.71 2.50 268.97 0.354 0.196 0.000 0.567
F9 SW APARTMENT 1.71 2.50 268.96 0.354 0.338 0.000 0.587
F9 NW APARTMENT 1.71 2.50 268.96 0.353 0.338 0.000 0.569
F9 SE APARTMENT 1.71 2.50 268.96 0.354 0.338 0.000 0.588
F9 NE APARTMENT 1.71 2.50 268.96 0.353 0.338 0.000 0.569
F9 N1 APARTMENT 1.71 2.50 268.96 0.354 0.204 0.000 0.566
F9 N2 APARTMENT 1.71 2.50 268.97 0.354 0.204 0.000 0.566
F9 S1 APARTMENT 1.71 2.50 268.96 0.354 0.204 0.000 0.586
F9 S2 APARTMENT 1.71 2.50 268.97 0.354 0.204 0.000 0.586
T SW APARTMENT 1.71 2.50 268.96 0.353 0.351 0.000 0.600
T NW APARTMENT 1.71 2.50 268.96 0.353 0.351 0.000 0.581
T SE APARTMENT 1.71 2.50 268.96 0.353 0.351 0.000 0.601
T NE APARTMENT 1.71 2.50 268.96 0.353 0.350 0.000 0.582
T N1 APARTMENT 1.71 2.50 268.96 0.353 0.211 0.000 0.578
T N2 APARTMENT 1.71 2.50 268.97 0.353 0.211 0.000 0.578
T S1 APARTMENT 1.71 2.50 268.96 0.354 0.212 0.000 0.599
T S2 APARTMENT 1.71 2.50 268.97 0.354 0.212 0.000 0.599
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
OFFICE 0.94 1.00 268.96 0.497 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.339 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.339 0.000 0.000 0.000
F2 SW APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F2 NW APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F2 SE APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F2 NE APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F2 N1 APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F2 N2 APARTMENT 1.71 2.50 268.97 0.339 0.000 0.000 0.000
F2 S1 APARTMENT 1.71 2.50 268.96 0.338 0.000 0.000 0.000
F2 S2 APARTMENT 1.71 2.50 268.97 0.339 0.000 0.000 0.000
F3 SW APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F3 NW APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F3 SE APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F3 NE APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F3 N1 APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F3 N2 APARTMENT 1.71 2.50 268.97 0.339 0.000 0.000 0.000
F3 S1 APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F3 S2 APARTMENT 1.71 2.50 268.97 0.339 0.000 0.000 0.000
F4 SW APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F4 NW APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F4 SE APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F4 NE APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F4 N1 APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F4 N2 APARTMENT 1.71 2.50 268.97 0.339 0.000 0.000 0.000
F4 S1 APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F4 S2 APARTMENT 1.71 2.50 268.97 0.339 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 0.339 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 0.339 0.000 0.000 0.000
F6 SW APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F6 NW APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F6 SE APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F6 NE APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F6 N1 APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F6 N2 APARTMENT 1.71 2.50 268.97 0.339 0.000 0.000 0.000
F6 S1 APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F6 S2 APARTMENT 1.71 2.50 268.97 0.339 0.000 0.000 0.000
F7 SW APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F7 NW APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F7 SE APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F7 NE APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F7 N1 APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F7 N2 APARTMENT 1.71 2.50 268.97 0.339 0.000 0.000 0.000
F7 S1 APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F7 S2 APARTMENT 1.71 2.50 268.97 0.339 0.000 0.000 0.000
F8 SW APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F8 NW APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F8 SE APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F8 NE APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F8 N1 APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F8 N2 APARTMENT 1.71 2.50 268.97 0.339 0.000 0.000 0.000
F8 S1 APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F8 S2 APARTMENT 1.71 2.50 268.97 0.339 0.000 0.000 0.000
F9 SW APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F9 NW APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F9 SE APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F9 NE APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F9 N1 APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F9 N2 APARTMENT 1.71 2.50 268.97 0.339 0.000 0.000 0.000
F9 S1 APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
F9 S2 APARTMENT 1.71 2.50 268.97 0.339 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.339 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.96 0.339 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.339 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:07

Surfaces by Class

Total Outdoors
Wall 420 140
Floor 90 9
Roof 90 9
Internal Mass 80 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 140 140
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 80
Conditioned Zones 80
Unconditioned Zones 10
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 4197
Defaulted Fields 814
Fields with Defaults 11307
Autosized Fields 1293
Autosizable Fields 1630
Autocalculated Fields 907
Autocalculatable Fields 1710



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2018-10-19 09:40:07

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 2926.66 56059.99 17-MAR-02:15 177237.97 13-AUG-19:30
Electricity:Building 1547.51 26803.46 01-JAN-03:15 79071.91 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity 416.41 7980.64 01-JAN-00:15 25049.15 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 348.50 6974.01 01-JAN-00:15 20603.34 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:OFFICE 29.50 508.27 01-JAN-00:15 2167.24 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 21.95 379.58 01-JAN-00:15 1622.33 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:G CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:F2 SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:F2 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:F3 SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:F3 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:F4 SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:F4 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:M SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M CORRIDOR 37.06 1175.12 01-JAN-00:15 1175.12 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 37.06 1175.12 01-JAN-00:15 1175.12 01-JAN-00:15
Electricity:Zone:F6 SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:F6 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:F7 SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:F7 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:F8 SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:F8 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:F9 SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:F9 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:T SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T CORRIDOR 177.27 1611.36 01-JAN-00:15 10825.51 01-JAN-07:15
InteriorLights:Electricity:Zone:T CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 67.92 1006.63 01-JAN-00:15 4445.81 01-JAN-19:15
InteriorEquipment:Electricity 1131.09 18822.82 01-JAN-03:15 56933.81 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 1131.09 18822.82 01-JAN-03:15 56933.81 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 7.55 128.69 01-JAN-00:15 544.91 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T CORRIDOR 158.74 1023.79 01-JAN-00:15 10237.95 01-JAN-07:15
Fans:Electricity 571.40 18118.97 18-JAN-13:45 18118.97 01-JAN-00:15
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Electricity:HVAC 1149.62 18499.50 17-MAR-02:15 92791.75 27-JUN-16:15
ElectricityProduced:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityProduced:HVAC 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricityProduced 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 2926.66 56059.99 17-MAR-02:15 177237.97 13-AUG-19:30
ElectricityPurchased:Plant 2926.66 56059.99 17-MAR-02:15 177237.97 13-AUG-19:30
Cogeneration:ElectricityPurchased 2926.66 56059.99 17-MAR-02:15 177237.97 13-AUG-19:30
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 2926.66 56059.99 17-MAR-02:15 177237.97 13-AUG-19:30
ElectricityNet:Plant 2926.66 56059.99 17-MAR-02:15 177237.97 13-AUG-19:30
Cogeneration:ElectricityNet 2926.66 56059.99 17-MAR-02:15 177237.97 13-AUG-19:30
ExteriorLights:Electricity 168.23 0.00 01-JAN-08:00 10720.10 01-JAN-00:15
General:ExteriorLights:Electricity 168.23 0.00 01-JAN-08:00 10720.10 01-JAN-00:15
General:Fans:Electricity 571.40 18118.97 18-JAN-13:45 18118.97 01-JAN-00:15
Cooling:Electricity 265.22 0.00 01-JAN-00:15 73776.41 27-JUN-15:30
Heating:Electricity 292.18 0.00 12-MAR-12:30 64984.55 06-FEB-10:00
Electricity:Plant 61.30 36.93 12-MAR-12:30 4524.54 20-JUL-21:00
HeatRejection:Electricity 11.44 0.00 01-JAN-00:15 2902.66 20-JUL-21:00
Boiler Parasitic:Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Pumps:Electricity 49.85 36.93 12-MAR-12:30 1621.88 01-JAN-00:15
WIRED_LTG_ELECTRICITY 0.62 0.00 01-JAN-00:15 37.57 01-JAN-19:30
WIRED_INT_EQUIP 973.17 1018.50 01-JAN-00:15 10185.00 01-JAN-07:15


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 2279.14 9260.51 12-MAR-22:45 329207.69 06-FEB-09:45
Gas:Plant 2279.14 9260.51 12-MAR-22:45 329207.69 06-FEB-09:45
WaterSystems:Gas 1228.41 9260.51 01-JAN-00:15 90685.17 13-FEB-08:00
Water Heater:WaterSystems:Gas 1228.41 9260.51 01-JAN-00:15 90685.17 13-FEB-08:00
Heating:Gas 1050.73 0.00 09-MAR-19:00 248248.26 06-FEB-10:00
Boiler:Heating:Gas 1050.73 0.00 09-MAR-19:00 248248.26 06-FEB-10:00


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
PlantLoopCoolingDemand:Facility 1115.08 0.00 01-JAN-00:15 361181.80 27-JUN-15:45
PlantLoopCoolingDemand:HVAC 1115.08 0.00 01-JAN-00:15 361181.80 27-JUN-15:45
CoolingCoils:PlantLoopCoolingDemand 1115.08 0.00 01-JAN-00:15 361181.80 27-JUN-15:45


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 5541.46 0.00 01-JAN-02:30 0.00 21-JUL-07:00
Water:Plant 5541.46 0.00 01-JAN-02:30 0.00 21-JUL-07:00
WaterSystems:Water 4778.51 0.00 01-JAN-02:30 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
MainsWater:Facility 5541.46 0.00 01-JAN-02:30 0.00 21-JUL-07:00
MainsWater:Plant 5541.46 0.00 01-JAN-02:30 0.00 21-JUL-07:00
WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:30 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
sub cat:WaterSystems:Water 4778.51 0.00 01-JAN-02:30 0.00 01-JAN-07:15
sub cat:WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:30 0.00 01-JAN-07:15
HeatRejection:Water 762.95 0.00 01-JAN-00:15 0.00 15-JUL-15:00
HeatRejection:MainsWater 762.95 0.00 01-JAN-00:15 0.00 15-JUL-15:00


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 1804.86 506.51 16-AUG-01:15 254247.30 06-FEB-10:00
PlantLoopHeatingDemand:Plant 934.21 506.51 16-AUG-01:15 63470.04 15-FEB-07:45
WaterSystems:PlantLoopHeatingDemand 934.21 506.51 16-AUG-01:15 63470.04 15-FEB-07:45
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 5156.67 4937.08 27-NOV-03:45 708741.19 06-FEB-10:00
EnergyTransfer:Building 1379.48 2955.95 09-APR-14:30 191931.11 06-FEB-10:00
EnergyTransfer:Zone:G SW APARTMENT 15.16 0.01 08-OCT-10:45 2617.00 21-SEP-15:30
Heating:EnergyTransfer 680.56 0.00 12-MAR-10:30 191931.11 06-FEB-10:00
Heating:EnergyTransfer:Zone:G SW APARTMENT 8.39 0.00 05-JAN-12:30 2213.90 06-FEB-09:30
Cooling:EnergyTransfer 698.92 0.00 01-JAN-00:15 179779.72 17-AUG-17:15
Cooling:EnergyTransfer:Zone:G SW APARTMENT 6.77 0.00 01-JAN-00:15 2617.00 21-SEP-15:30
EnergyTransfer:Zone:G NW APARTMENT 15.83 0.02 30-OCT-12:15 2378.56 07-FEB-08:30
Heating:EnergyTransfer:Zone:G NW APARTMENT 10.94 0.00 08-MAR-14:45 2378.56 07-FEB-08:30
Cooling:EnergyTransfer:Zone:G NW APARTMENT 4.89 0.00 01-JAN-00:15 2173.45 10-JUL-18:30
EnergyTransfer:Zone:OFFICE 19.93 0.06 23-OCT-02:30 3025.40 21-SEP-13:15
Heating:EnergyTransfer:Zone:OFFICE 7.95 0.00 02-JAN-11:00 2219.28 13-FEB-08:00
Cooling:EnergyTransfer:Zone:OFFICE 11.98 0.00 01-JAN-00:15 3025.40 21-SEP-13:15
EnergyTransfer:Zone:G NE APARTMENT 15.62 0.01 23-JUL-08:15 2256.93 06-FEB-10:00
Heating:EnergyTransfer:Zone:G NE APARTMENT 10.69 0.00 09-MAR-19:00 2256.93 06-FEB-10:00
Cooling:EnergyTransfer:Zone:G NE APARTMENT 4.94 0.00 01-JAN-00:15 1598.89 05-AUG-09:45
EnergyTransfer:Zone:G N1 APARTMENT 10.21 0.03 08-APR-15:45 1589.39 10-NOV-11:00
Heating:EnergyTransfer:Zone:G N1 APARTMENT 5.80 0.00 16-JAN-21:30 1589.39 10-NOV-11:00
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 4.41 0.00 01-JAN-00:15 1188.97 08-AUG-18:15
EnergyTransfer:Zone:G N2 APARTMENT 10.20 0.00 09-MAY-15:00 1590.21 10-NOV-11:00
Heating:EnergyTransfer:Zone:G N2 APARTMENT 5.79 0.00 17-JAN-18:45 1590.21 10-NOV-11:00
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 4.41 0.00 01-JAN-00:15 1176.06 05-AUG-17:45
EnergyTransfer:Zone:G S1 APARTMENT 10.07 0.02 08-JUN-11:00 1730.92 21-SEP-14:30
Heating:EnergyTransfer:Zone:G S1 APARTMENT 3.45 0.00 04-JAN-10:30 1429.50 10-NOV-11:00
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 6.62 0.00 01-JAN-00:15 1730.92 21-SEP-14:30
EnergyTransfer:Zone:G S2 APARTMENT 10.09 0.01 13-JUL-09:00 1788.05 21-SEP-14:30
Heating:EnergyTransfer:Zone:G S2 APARTMENT 3.36 0.00 04-JAN-10:15 1383.18 10-NOV-11:00
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 6.73 0.00 01-JAN-00:15 1788.05 21-SEP-14:30
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F2 SW APARTMENT 18.54 0.06 06-MAR-20:45 3288.76 21-SEP-15:30
Heating:EnergyTransfer:Zone:F2 SW APARTMENT 7.53 0.00 04-JAN-13:00 2416.41 06-FEB-10:00
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT 11.01 0.00 01-JAN-00:15 3288.76 21-SEP-15:30
EnergyTransfer:Zone:F2 NW APARTMENT 18.39 0.01 23-SEP-22:00 2789.42 10-JUL-18:30
Heating:EnergyTransfer:Zone:F2 NW APARTMENT 10.56 0.00 07-MAR-16:30 2523.23 06-FEB-10:00
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT 7.82 0.00 01-JAN-00:15 2789.42 10-JUL-18:30
EnergyTransfer:Zone:F2 SE APARTMENT 18.69 0.09 13-MAR-02:00 2863.30 21-SEP-14:15
Heating:EnergyTransfer:Zone:F2 SE APARTMENT 6.97 0.00 04-JAN-10:30 2399.28 13-FEB-06:00
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT 11.71 0.00 01-JAN-00:15 2863.30 21-SEP-14:15
EnergyTransfer:Zone:F2 NE APARTMENT 18.14 0.03 23-AUG-08:30 2478.31 06-FEB-10:00
Heating:EnergyTransfer:Zone:F2 NE APARTMENT 10.27 0.00 08-MAR-13:00 2478.31 06-FEB-10:00
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT 7.87 0.00 01-JAN-00:15 2124.88 05-AUG-09:45
EnergyTransfer:Zone:F2 N1 APARTMENT 11.26 0.03 30-MAY-17:00 1988.37 10-NOV-11:00
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT 4.30 0.00 01-JAN-18:15 1988.37 10-NOV-11:00
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT 6.95 0.00 01-JAN-00:15 1647.37 25-JUL-18:15
EnergyTransfer:Zone:F2 N2 APARTMENT 11.25 0.01 14-JUL-07:45 1992.52 10-NOV-11:00
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT 4.30 0.00 01-JAN-18:15 1992.52 10-NOV-11:00
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT 6.95 0.00 01-JAN-00:15 1631.90 25-JUL-18:15
EnergyTransfer:Zone:F2 S1 APARTMENT 12.92 0.01 23-AUG-08:15 2281.23 21-SEP-14:30
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT 2.31 0.00 01-JAN-17:15 1694.58 10-NOV-11:00
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT 10.61 0.00 01-JAN-00:15 2281.23 21-SEP-14:30
EnergyTransfer:Zone:F2 S2 APARTMENT 12.96 0.00 20-AUG-08:45 2303.86 21-SEP-14:30
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT 2.29 0.00 01-JAN-17:15 1685.54 10-NOV-11:00
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT 10.67 0.00 01-JAN-00:15 2303.86 21-SEP-14:30
EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F3 SW APARTMENT 19.42 0.03 08-APR-03:15 3320.65 21-SEP-15:30
Heating:EnergyTransfer:Zone:F3 SW APARTMENT 7.87 0.00 05-JAN-12:45 2615.76 13-FEB-06:00
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT 11.55 0.00 01-JAN-00:15 3320.65 21-SEP-15:30
EnergyTransfer:Zone:F3 NW APARTMENT 19.22 0.01 14-MAR-00:15 2959.39 25-JUL-17:45
Heating:EnergyTransfer:Zone:F3 NW APARTMENT 10.94 0.00 14-FEB-16:00 2714.14 06-FEB-10:00
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT 8.28 0.00 01-JAN-00:15 2959.39 25-JUL-17:45
EnergyTransfer:Zone:F3 SE APARTMENT 19.35 0.17 04-NOV-11:15 2817.43 08-AUG-12:00
Heating:EnergyTransfer:Zone:F3 SE APARTMENT 7.62 0.00 04-JAN-11:00 2602.16 13-FEB-06:00
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT 11.73 0.00 01-JAN-00:15 2817.43 08-AUG-12:00
EnergyTransfer:Zone:F3 NE APARTMENT 18.97 0.03 23-OCT-02:00 2666.54 06-FEB-10:00
Heating:EnergyTransfer:Zone:F3 NE APARTMENT 10.65 0.00 08-MAR-12:00 2666.54 06-FEB-10:00
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT 8.33 0.00 01-JAN-00:15 2229.13 06-AUG-18:00
EnergyTransfer:Zone:F3 N1 APARTMENT 11.80 0.01 24-SEP-11:15 2325.21 10-NOV-11:00
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT 4.28 0.00 01-JAN-17:45 2325.21 10-NOV-11:00
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT 7.53 0.00 01-JAN-00:15 1759.56 08-AUG-18:00
EnergyTransfer:Zone:F3 N2 APARTMENT 11.79 0.02 03-MAY-14:30 2329.98 10-NOV-11:00
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT 4.27 0.00 01-JAN-17:45 2329.98 10-NOV-11:00
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT 7.52 0.00 01-JAN-00:15 1744.76 08-AUG-18:00
EnergyTransfer:Zone:F3 S1 APARTMENT 13.77 0.00 04-NOV-18:45 2330.47 21-SEP-14:30
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT 2.31 0.00 01-JAN-06:30 2053.56 10-NOV-11:00
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT 11.45 0.00 01-JAN-00:15 2330.47 21-SEP-14:30
EnergyTransfer:Zone:F3 S2 APARTMENT 13.78 0.03 10-OCT-15:45 2342.17 21-SEP-14:30
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT 2.31 0.00 01-JAN-06:30 2054.21 10-NOV-11:00
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT 11.47 0.00 01-JAN-00:15 2342.17 21-SEP-14:30
EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F4 SW APARTMENT 20.03 0.01 28-MAY-11:30 3332.32 21-SEP-15:30
Heating:EnergyTransfer:Zone:F4 SW APARTMENT 8.49 0.00 05-JAN-13:00 2806.78 13-FEB-06:00
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT 11.54 0.00 01-JAN-00:15 3332.32 21-SEP-15:30
EnergyTransfer:Zone:F4 NW APARTMENT 19.91 0.00 21-JUN-12:15 3009.55 25-JUL-17:45
Heating:EnergyTransfer:Zone:F4 NW APARTMENT 11.61 0.00 14-FEB-16:00 2900.94 06-FEB-10:00
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT 8.30 0.00 01-JAN-00:15 3009.55 25-JUL-17:45
EnergyTransfer:Zone:F4 SE APARTMENT 19.93 0.10 14-APR-20:00 2847.80 08-AUG-12:00
Heating:EnergyTransfer:Zone:F4 SE APARTMENT 8.29 0.00 05-JAN-13:00 2792.83 13-FEB-06:00
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT 11.64 0.00 01-JAN-00:15 2847.80 08-AUG-12:00
EnergyTransfer:Zone:F4 NE APARTMENT 19.68 0.01 11-APR-14:00 2851.68 06-FEB-10:00
Heating:EnergyTransfer:Zone:F4 NE APARTMENT 11.32 0.00 08-MAR-13:00 2851.68 06-FEB-10:00
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT 8.36 0.00 01-JAN-00:15 2292.61 06-AUG-18:00
EnergyTransfer:Zone:F4 N1 APARTMENT 12.19 0.00 03-JUL-08:30 1831.13 27-NOV-09:15
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT 4.56 0.00 01-JAN-06:30 1831.13 27-NOV-09:15
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT 7.64 0.00 01-JAN-00:15 1786.54 08-AUG-18:00
EnergyTransfer:Zone:F4 N2 APARTMENT 12.18 0.02 11-MAR-04:30 1834.48 27-NOV-09:15
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT 4.55 0.00 01-JAN-06:30 1834.48 27-NOV-09:15
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT 7.63 0.00 01-JAN-00:15 1771.75 08-AUG-18:00
EnergyTransfer:Zone:F4 S1 APARTMENT 14.12 0.01 24-SEP-18:45 2348.75 21-SEP-14:30
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT 2.54 0.00 01-JAN-06:30 1456.29 13-FEB-04:00
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT 11.58 0.00 01-JAN-00:15 2348.75 21-SEP-14:30
EnergyTransfer:Zone:F4 S2 APARTMENT 14.11 0.03 14-JUN-14:15 2358.88 21-SEP-14:30
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT 2.54 0.00 01-JAN-06:30 1455.81 13-FEB-04:00
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT 11.57 0.00 01-JAN-00:15 2358.88 21-SEP-14:30
EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M SW APARTMENT 20.50 0.02 12-SEP-18:15 3356.29 21-SEP-15:30
Heating:EnergyTransfer:Zone:M SW APARTMENT 8.96 0.00 05-JAN-13:15 2954.50 13-FEB-06:00
Cooling:EnergyTransfer:Zone:M SW APARTMENT 11.54 0.00 01-JAN-00:15 3356.29 21-SEP-15:30
EnergyTransfer:Zone:M NW APARTMENT 20.46 0.00 06-NOV-02:15 3069.92 25-JUL-17:30
Heating:EnergyTransfer:Zone:M NW APARTMENT 12.08 0.00 14-FEB-16:00 3042.36 06-FEB-10:00
Cooling:EnergyTransfer:Zone:M NW APARTMENT 8.38 0.00 01-JAN-00:15 3069.92 25-JUL-17:30
EnergyTransfer:Zone:M SE APARTMENT 20.38 0.03 26-OCT-01:00 2940.09 13-FEB-06:00
Heating:EnergyTransfer:Zone:M SE APARTMENT 8.76 0.00 05-JAN-13:15 2940.09 13-FEB-06:00
Cooling:EnergyTransfer:Zone:M SE APARTMENT 11.62 0.00 01-JAN-00:15 2897.12 08-AUG-12:00
EnergyTransfer:Zone:M NE APARTMENT 20.22 0.08 04-JUN-11:00 2993.09 13-FEB-06:00
Heating:EnergyTransfer:Zone:M NE APARTMENT 11.77 0.00 08-MAR-13:00 2993.09 13-FEB-06:00
Cooling:EnergyTransfer:Zone:M NE APARTMENT 8.45 0.00 01-JAN-00:15 2357.54 06-AUG-18:00
EnergyTransfer:Zone:M N1 APARTMENT 12.52 0.01 27-SEP-11:00 2002.22 27-NOV-09:15
Heating:EnergyTransfer:Zone:M N1 APARTMENT 4.73 0.00 01-JAN-06:30 2002.22 27-NOV-09:15
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 7.79 0.00 01-JAN-00:15 1831.98 08-AUG-18:00
EnergyTransfer:Zone:M N2 APARTMENT 12.51 0.00 04-JUN-11:45 2005.49 27-NOV-09:15
Heating:EnergyTransfer:Zone:M N2 APARTMENT 4.72 0.00 01-JAN-06:30 2005.49 27-NOV-09:15
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 7.78 0.00 01-JAN-00:15 1817.22 08-AUG-18:00
EnergyTransfer:Zone:M S1 APARTMENT 14.38 0.03 04-MAY-15:15 2386.83 21-SEP-14:30
Heating:EnergyTransfer:Zone:M S1 APARTMENT 2.71 0.00 01-JAN-06:30 1533.56 13-FEB-04:00
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 11.67 0.00 01-JAN-00:15 2386.83 21-SEP-14:30
EnergyTransfer:Zone:M S2 APARTMENT 14.38 0.01 10-JUN-12:30 2396.72 21-SEP-14:30
Heating:EnergyTransfer:Zone:M S2 APARTMENT 2.71 0.00 01-JAN-06:30 1533.11 13-FEB-04:00
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 11.66 0.00 01-JAN-00:15 2396.72 21-SEP-14:30
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F6 SW APARTMENT 20.72 0.05 14-MAR-01:15 3307.59 21-SEP-15:30
Heating:EnergyTransfer:Zone:F6 SW APARTMENT 9.95 0.00 06-JAN-10:30 3141.30 13-FEB-06:00
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT 10.78 0.00 01-JAN-00:15 3307.59 21-SEP-15:30
EnergyTransfer:Zone:F6 NW APARTMENT 21.03 0.01 27-NOV-10:00 3222.70 06-FEB-10:00
Heating:EnergyTransfer:Zone:F6 NW APARTMENT 13.22 0.00 08-MAR-14:15 3222.70 06-FEB-10:00
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT 7.81 0.00 01-JAN-00:15 3048.79 25-JUL-17:30
EnergyTransfer:Zone:F6 SE APARTMENT 20.58 0.02 06-SEP-11:00 3126.48 13-FEB-06:00
Heating:EnergyTransfer:Zone:F6 SE APARTMENT 9.73 0.00 06-JAN-10:15 3126.48 13-FEB-06:00
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT 10.85 0.00 01-JAN-00:15 2876.43 08-AUG-12:00
EnergyTransfer:Zone:F6 NE APARTMENT 20.78 0.04 21-OCT-22:45 3178.67 13-FEB-06:00
Heating:EnergyTransfer:Zone:F6 NE APARTMENT 12.90 0.00 09-MAR-12:00 3178.67 13-FEB-06:00
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT 7.88 0.00 01-JAN-00:15 2348.05 06-AUG-11:00
EnergyTransfer:Zone:F6 N1 APARTMENT 12.65 0.02 22-JUN-10:00 2241.66 27-NOV-09:15
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT 5.43 0.00 01-JAN-18:15 2241.66 27-NOV-09:15
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT 7.22 0.00 01-JAN-00:15 1803.33 08-AUG-18:00
EnergyTransfer:Zone:F6 N2 APARTMENT 12.64 0.01 21-JUN-09:30 2244.48 27-NOV-09:15
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT 5.42 0.00 01-JAN-18:15 2244.48 27-NOV-09:15
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT 7.22 0.00 01-JAN-00:15 1788.65 08-AUG-18:00
EnergyTransfer:Zone:F6 S1 APARTMENT 14.03 0.02 07-JUL-08:00 2349.97 21-SEP-14:30
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT 3.20 0.00 01-JAN-06:30 1656.13 13-FEB-04:00
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT 10.83 0.00 01-JAN-00:15 2349.97 21-SEP-14:30
EnergyTransfer:Zone:F6 S2 APARTMENT 14.03 0.01 26-MAR-10:15 2359.86 21-SEP-14:30
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT 3.20 0.00 01-JAN-06:30 1655.66 13-FEB-04:00
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT 10.83 0.00 01-JAN-00:15 2359.86 21-SEP-14:30
EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F7 SW APARTMENT 21.02 0.12 15-MAR-01:00 3292.39 13-FEB-06:00
Heating:EnergyTransfer:Zone:F7 SW APARTMENT 10.72 0.00 06-JAN-10:30 3292.39 13-FEB-06:00
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT 10.30 0.00 01-JAN-00:15 3281.37 21-SEP-15:30
EnergyTransfer:Zone:F7 NW APARTMENT 21.55 0.01 08-APR-03:45 3366.14 06-FEB-10:00
Heating:EnergyTransfer:Zone:F7 NW APARTMENT 14.07 0.00 08-MAR-14:30 3366.14 06-FEB-10:00
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT 7.49 0.00 01-JAN-00:15 3042.34 25-JUL-17:30
EnergyTransfer:Zone:F7 SE APARTMENT 20.87 0.05 23-OCT-03:30 3277.26 13-FEB-06:00
Heating:EnergyTransfer:Zone:F7 SE APARTMENT 10.50 0.00 06-JAN-10:15 3277.26 13-FEB-06:00
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT 10.36 0.00 01-JAN-00:15 2876.75 08-AUG-12:00
EnergyTransfer:Zone:F7 NE APARTMENT 21.30 0.01 12-APR-17:00 3327.01 13-FEB-06:00
Heating:EnergyTransfer:Zone:F7 NE APARTMENT 13.74 0.00 09-MAR-12:00 3327.01 13-FEB-06:00
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT 7.55 0.00 01-JAN-00:15 2345.00 06-AUG-11:00
EnergyTransfer:Zone:F7 N1 APARTMENT 12.84 0.01 11-SEP-15:00 2443.95 27-NOV-09:15
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT 5.95 0.00 02-JAN-19:00 2443.95 27-NOV-09:15
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT 6.89 0.00 01-JAN-00:15 1799.50 08-AUG-18:00
EnergyTransfer:Zone:F7 N2 APARTMENT 12.83 0.01 07-JUN-09:45 2446.34 27-NOV-09:15
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT 5.94 0.00 02-JAN-19:00 2446.34 27-NOV-09:15
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT 6.89 0.00 01-JAN-00:15 1784.89 08-AUG-18:00
EnergyTransfer:Zone:F7 S1 APARTMENT 13.92 0.04 10-JUN-10:15 2338.97 21-SEP-14:30
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT 3.60 0.00 01-JAN-06:30 1754.13 13-FEB-04:00
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT 10.32 0.00 01-JAN-00:15 2338.97 21-SEP-14:30
EnergyTransfer:Zone:F7 S2 APARTMENT 13.92 0.03 27-MAY-09:00 2348.87 21-SEP-14:30
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT 3.60 0.00 01-JAN-06:30 1753.67 13-FEB-04:00
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT 10.32 0.00 01-JAN-00:15 2348.87 21-SEP-14:30
EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F8 SW APARTMENT 21.42 0.03 30-MAY-23:30 3435.08 13-FEB-06:00
Heating:EnergyTransfer:Zone:F8 SW APARTMENT 11.48 0.00 06-JAN-10:30 3435.08 13-FEB-06:00
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT 9.94 0.00 01-JAN-00:15 3259.43 21-SEP-15:30
EnergyTransfer:Zone:F8 NW APARTMENT 22.16 0.04 14-NOV-20:15 3502.46 06-FEB-10:00
Heating:EnergyTransfer:Zone:F8 NW APARTMENT 14.90 0.00 08-MAR-14:45 3502.46 06-FEB-10:00
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT 7.26 0.00 01-JAN-00:15 3049.14 25-JUL-17:30
EnergyTransfer:Zone:F8 SE APARTMENT 21.25 0.13 26-OCT-00:15 3419.81 13-FEB-06:00
Heating:EnergyTransfer:Zone:F8 SE APARTMENT 11.25 0.00 06-JAN-10:15 3419.81 13-FEB-06:00
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT 10.00 0.00 01-JAN-00:15 2885.35 08-AUG-12:00
EnergyTransfer:Zone:F8 NE APARTMENT 21.89 0.04 22-MAR-11:45 3465.93 13-FEB-06:00
Heating:EnergyTransfer:Zone:F8 NE APARTMENT 14.57 0.00 09-MAR-16:30 3465.93 13-FEB-06:00
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT 7.33 0.00 01-JAN-00:15 2359.61 06-AUG-11:15
EnergyTransfer:Zone:F8 N1 APARTMENT 13.14 0.01 08-JUL-07:00 2620.51 27-NOV-09:15
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT 6.48 0.00 14-JAN-16:30 2620.51 27-NOV-09:15
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT 6.66 0.00 01-JAN-00:15 1809.23 08-AUG-18:00
EnergyTransfer:Zone:F8 N2 APARTMENT 13.13 0.03 05-JUL-07:00 2622.67 27-NOV-09:15
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT 6.47 0.00 14-JAN-16:30 2622.67 27-NOV-09:15
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT 6.66 0.00 01-JAN-00:15 1794.70 08-AUG-18:00
EnergyTransfer:Zone:F8 S1 APARTMENT 13.94 0.02 27-NOV-05:00 2341.13 21-SEP-14:30
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT 4.02 0.00 02-JAN-18:45 1899.25 27-NOV-09:15
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT 9.92 0.00 01-JAN-00:15 2341.13 21-SEP-14:30
EnergyTransfer:Zone:F8 S2 APARTMENT 13.93 0.04 10-DEC-17:45 2351.06 21-SEP-14:30
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT 4.02 0.00 02-JAN-18:45 1902.36 27-NOV-09:15
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT 9.91 0.00 01-JAN-00:15 2351.06 21-SEP-14:30
EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F9 SW APARTMENT 22.62 0.01 16-NOV-04:30 3672.41 13-FEB-06:00
Heating:EnergyTransfer:Zone:F9 SW APARTMENT 12.96 0.00 06-JAN-10:45 3672.41 13-FEB-06:00
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT 9.66 0.00 01-JAN-00:15 3310.42 17-AUG-17:15
EnergyTransfer:Zone:F9 NW APARTMENT 23.70 0.01 27-APR-12:30 3740.21 06-FEB-10:00
Heating:EnergyTransfer:Zone:F9 NW APARTMENT 16.52 0.00 08-MAR-15:15 3740.21 06-FEB-10:00
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT 7.17 0.00 01-JAN-00:15 3139.09 25-JUL-17:30
EnergyTransfer:Zone:F9 SE APARTMENT 22.40 0.07 07-SEP-03:15 3657.00 13-FEB-06:00
Heating:EnergyTransfer:Zone:F9 SE APARTMENT 12.71 0.00 06-JAN-10:15 3657.00 13-FEB-06:00
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT 9.69 0.00 01-JAN-00:15 2932.57 08-AUG-12:00
EnergyTransfer:Zone:F9 NE APARTMENT 23.38 0.11 11-MAR-19:00 3693.65 13-FEB-06:00
Heating:EnergyTransfer:Zone:F9 NE APARTMENT 16.15 0.00 09-MAR-17:15 3693.65 13-FEB-06:00
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT 7.23 0.00 01-JAN-00:15 2397.24 06-AUG-11:15
EnergyTransfer:Zone:F9 N1 APARTMENT 14.18 0.00 07-APR-18:45 2784.02 27-NOV-09:15
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT 7.70 0.00 14-JAN-17:15 2784.02 27-NOV-09:15
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT 6.49 0.00 01-JAN-00:15 1894.43 08-AUG-18:00
EnergyTransfer:Zone:F9 N2 APARTMENT 14.18 0.02 20-MAY-18:30 2786.44 27-NOV-09:15
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT 7.69 0.00 14-JAN-17:15 2786.44 27-NOV-09:15
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT 6.49 0.00 01-JAN-00:15 1879.72 08-AUG-18:00
EnergyTransfer:Zone:F9 S1 APARTMENT 14.45 0.00 26-SEP-19:30 2377.54 21-SEP-14:30
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT 4.97 0.00 04-JAN-10:45 2119.50 27-NOV-09:15
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT 9.48 0.00 01-JAN-00:15 2377.54 21-SEP-14:30
EnergyTransfer:Zone:F9 S2 APARTMENT 14.45 0.02 29-AUG-09:15 2383.85 21-SEP-14:15
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT 4.97 0.00 04-JAN-10:45 2122.12 27-NOV-09:15
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT 9.48 0.00 01-JAN-00:15 2383.85 21-SEP-14:15
EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:T SW APARTMENT 28.49 0.02 21-AUG-02:45 4359.41 13-FEB-06:00
Heating:EnergyTransfer:Zone:T SW APARTMENT 19.01 0.00 06-JAN-10:45 4359.41 13-FEB-06:00
Cooling:EnergyTransfer:Zone:T SW APARTMENT 9.48 0.00 01-JAN-00:15 3943.83 21-SEP-15:15
EnergyTransfer:Zone:T NW APARTMENT 29.32 0.01 31-AUG-10:00 4377.07 13-FEB-06:00
Heating:EnergyTransfer:Zone:T NW APARTMENT 22.18 0.00 08-MAR-13:15 4377.07 13-FEB-06:00
Cooling:EnergyTransfer:Zone:T NW APARTMENT 7.14 0.00 01-JAN-00:15 3596.91 25-JUL-17:30
EnergyTransfer:Zone:T SE APARTMENT 28.08 0.01 06-OCT-20:30 4342.40 13-FEB-06:00
Heating:EnergyTransfer:Zone:T SE APARTMENT 18.70 0.00 06-JAN-10:30 4342.40 13-FEB-06:00
Cooling:EnergyTransfer:Zone:T SE APARTMENT 9.38 0.00 01-JAN-00:15 3582.82 08-AUG-12:00
EnergyTransfer:Zone:T NE APARTMENT 28.76 0.00 09-JUN-00:15 4360.33 13-FEB-06:00
Heating:EnergyTransfer:Zone:T NE APARTMENT 21.72 0.00 08-MAR-12:30 4360.33 13-FEB-06:00
Cooling:EnergyTransfer:Zone:T NE APARTMENT 7.04 0.00 01-JAN-00:15 2776.10 06-AUG-11:00
EnergyTransfer:Zone:T N1 APARTMENT 18.88 0.01 05-NOV-00:15 3059.39 27-NOV-09:15
Heating:EnergyTransfer:Zone:T N1 APARTMENT 12.71 0.00 10-FEB-13:00 3059.39 27-NOV-09:15
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 6.17 0.00 01-JAN-00:15 2230.12 17-AUG-17:15
EnergyTransfer:Zone:T N2 APARTMENT 18.87 0.02 27-NOV-01:15 3060.32 27-NOV-09:15
Heating:EnergyTransfer:Zone:T N2 APARTMENT 12.71 0.00 10-FEB-13:00 3060.32 27-NOV-09:15
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 6.16 0.00 01-JAN-00:15 2218.75 25-JUL-17:00
EnergyTransfer:Zone:T S1 APARTMENT 18.64 0.03 13-MAR-04:30 3029.94 08-AUG-12:15
Heating:EnergyTransfer:Zone:T S1 APARTMENT 9.99 0.00 04-JAN-11:00 2736.26 13-FEB-04:00
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 8.65 0.00 01-JAN-00:15 3029.94 08-AUG-12:15
EnergyTransfer:Zone:T S2 APARTMENT 18.64 0.00 27-SEP-01:30 3050.28 08-AUG-12:15
Heating:EnergyTransfer:Zone:T S2 APARTMENT 9.99 0.00 04-JAN-11:00 2735.92 13-FEB-04:00
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 8.65 0.00 01-JAN-00:15 3050.28 08-AUG-12:15
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Plant 1774.35 506.51 16-AUG-01:15 251765.86 06-FEB-10:00
WaterSystems:EnergyTransfer 934.20 506.51 16-AUG-01:15 63463.55 15-FEB-07:45
sub cat:WaterSystems:EnergyTransfer 934.20 506.51 16-AUG-01:15 63463.55 15-FEB-07:45
EnergyTransfer:HVAC 2002.84 0.00 12-MAR-12:30 287451.49 27-JUN-15:45
CoolingCoils:EnergyTransfer 872.50 0.00 01-JAN-00:15 287451.49 27-JUN-15:45
HeatingCoils:EnergyTransfer 1130.34 0.00 12-MAR-12:30 265044.22 06-FEB-10:00
PlantLoopHeatingDemand:HVAC 870.65 0.00 12-MAR-12:30 201080.05 06-FEB-10:00
HeatingCoils:PlantLoopHeatingDemand 870.65 0.00 12-MAR-12:30 201080.05 06-FEB-10:00
Boilers:EnergyTransfer 840.14 0.00 09-MAR-19:00 198598.61 06-FEB-10:00



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:07

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 8.391 -6.766 0.000 0.000 3.868 2.413 12.213 15.882 0.000 0.163 0.000 0.000 -12.085 0.000 -8.991 -15.089
G NW APARTMENT 10.938 -4.895 0.000 0.000 3.890 2.413 12.213 8.585 0.000 0.163 0.000 0.000 -12.598 0.000 -8.642 -12.066
OFFICE 7.948 -11.982 0.000 0.000 0.536 21.954 7.547 15.731 0.000 0.050 0.000 0.000 -12.054 0.000 -5.442 -24.286
G NE APARTMENT 10.686 -4.937 0.000 0.000 3.902 2.413 12.213 8.444 0.000 0.162 0.000 0.000 -12.352 0.000 -8.633 -11.898
G N1 APARTMENT 5.797 -4.412 0.000 0.000 3.905 2.413 12.213 3.134 0.000 0.141 0.000 0.000 -7.872 0.000 -6.280 -9.039
G N2 APARTMENT 5.790 -4.412 0.000 0.000 3.905 2.413 12.213 3.133 0.000 0.141 0.000 0.000 -7.870 0.000 -6.279 -9.034
G S1 APARTMENT 3.450 -6.620 0.000 0.000 3.870 2.413 12.213 10.531 0.000 0.143 0.000 0.000 -7.380 0.000 -6.693 -11.927
G S2 APARTMENT 3.361 -6.732 0.000 0.000 3.867 2.413 12.213 10.519 0.000 0.144 0.000 0.000 -7.389 0.000 -6.731 -11.664
F2 SW APARTMENT 7.531 -11.011 0.000 0.000 3.808 2.413 12.213 15.201 0.000 0.215 0.000 0.000 -12.932 0.000 -12.393 -5.044
F2 NW APARTMENT 10.563 -7.824 0.000 0.000 3.847 2.413 12.213 8.138 0.000 0.213 0.000 0.000 -13.408 0.000 -11.899 -4.255
F2 SE APARTMENT 6.973 -11.713 0.000 0.000 3.806 2.413 12.213 15.120 0.000 0.215 0.000 0.000 -12.815 0.000 -12.505 -3.707
F2 NE APARTMENT 10.267 -7.870 0.000 0.000 3.858 2.413 12.213 8.019 0.000 0.211 0.000 0.000 -13.122 0.000 -11.889 -4.100
F2 N1 APARTMENT 4.303 -6.952 0.000 0.000 3.856 2.413 12.213 2.903 0.000 0.180 0.000 0.000 -8.430 0.000 -8.561 -1.925
F2 N2 APARTMENT 4.298 -6.949 0.000 0.000 3.857 2.413 12.213 2.902 0.000 0.179 0.000 0.000 -8.427 0.000 -8.560 -1.926
F2 S1 APARTMENT 2.307 -10.609 0.000 0.000 3.801 2.413 12.213 10.105 0.000 0.184 0.000 0.000 -7.906 0.000 -9.141 -3.367
F2 S2 APARTMENT 2.289 -10.670 0.000 0.000 3.800 2.413 12.213 10.100 0.000 0.185 0.000 0.000 -7.910 0.000 -9.156 -3.264
F3 SW APARTMENT 7.872 -11.548 0.000 0.000 3.801 2.413 12.213 14.941 0.000 0.278 0.000 0.000 -13.204 0.000 -14.252 -2.513
F3 NW APARTMENT 10.940 -8.279 0.000 0.000 3.839 2.413 12.213 7.980 0.000 0.276 0.000 0.000 -13.695 0.000 -13.720 -1.967
F3 SE APARTMENT 7.623 -11.731 0.000 0.000 3.805 2.413 12.213 14.909 0.000 0.278 0.000 0.000 -13.020 0.000 -14.287 -2.203
F3 NE APARTMENT 10.647 -8.326 0.000 0.000 3.849 2.413 12.213 7.873 0.000 0.270 0.000 0.000 -13.394 0.000 -13.708 -1.837
F3 N1 APARTMENT 4.275 -7.529 0.000 0.000 3.843 2.413 12.213 2.830 0.000 0.231 0.172 0.000 -8.625 0.000 -9.824 -0.000
F3 N2 APARTMENT 4.270 -7.523 0.000 0.000 3.844 2.413 12.213 2.830 0.000 0.230 0.169 0.000 -8.622 0.000 -9.823 -0.000
F3 S1 APARTMENT 2.314 -11.453 0.000 0.000 3.787 2.413 12.213 9.932 0.000 0.239 0.000 0.000 -8.093 0.000 -10.447 -0.905
F3 S2 APARTMENT 2.311 -11.468 0.000 0.000 3.787 2.413 12.213 9.930 0.000 0.239 0.000 0.000 -8.093 0.000 -10.454 -0.877
F4 SW APARTMENT 8.494 -11.540 0.000 0.000 3.801 2.413 12.213 14.785 0.000 0.302 0.000 0.000 -13.349 0.000 -15.361 -1.758
F4 NW APARTMENT 11.614 -8.299 0.000 0.000 3.837 2.413 12.213 7.891 0.000 0.299 0.000 0.000 -13.857 0.000 -14.831 -1.280
F4 SE APARTMENT 8.292 -11.638 0.000 0.000 3.806 2.413 12.213 14.769 0.000 0.301 0.000 0.000 -13.147 0.000 -15.380 -1.631
F4 NE APARTMENT 11.318 -8.365 0.000 0.000 3.847 2.413 12.213 7.791 0.000 0.292 0.000 0.000 -13.548 0.000 -14.815 -1.146
F4 N1 APARTMENT 4.555 -7.637 0.000 0.000 3.838 2.413 12.213 2.792 0.000 0.248 0.827 0.000 -8.735 0.000 -10.514 -0.000
F4 N2 APARTMENT 4.549 -7.632 0.000 0.000 3.839 2.413 12.213 2.791 0.000 0.247 0.825 0.000 -8.732 0.000 -10.513 -0.000
F4 S1 APARTMENT 2.545 -11.576 0.000 0.000 3.784 2.413 12.213 9.829 0.000 0.257 0.000 0.000 -8.190 0.000 -11.134 -0.141
F4 S2 APARTMENT 2.541 -11.572 0.000 0.000 3.784 2.413 12.213 9.827 0.000 0.257 0.000 0.000 -8.189 0.000 -11.138 -0.137
M SW APARTMENT 8.959 -11.538 0.000 0.000 3.802 2.413 12.213 14.666 0.000 0.320 0.000 0.000 -13.465 0.000 -16.489 -0.880
M NW APARTMENT 12.080 -8.376 0.000 0.000 3.837 2.413 12.213 7.824 0.000 0.317 0.000 0.000 -13.987 0.000 -15.939 -0.382
M SE APARTMENT 8.760 -11.621 0.000 0.000 3.808 2.413 12.213 14.657 0.000 0.318 0.000 0.000 -13.255 0.000 -16.507 -0.787
M NE APARTMENT 11.775 -8.445 0.000 0.000 3.847 2.413 12.213 7.728 0.000 0.308 0.000 0.000 -13.672 0.000 -15.921 -0.246
M N1 APARTMENT 4.733 -7.791 0.000 0.000 3.837 2.413 12.213 2.764 0.000 0.261 1.660 0.000 -8.821 0.000 -11.268 -0.000
M N2 APARTMENT 4.724 -7.783 0.000 0.000 3.838 2.413 12.213 2.763 0.000 0.260 1.658 0.000 -8.819 0.000 -11.267 -0.000
M S1 APARTMENT 2.713 -11.670 0.000 0.000 3.784 2.413 12.213 9.751 0.000 0.270 0.698 0.000 -8.265 0.000 -11.908 -0.000
M S2 APARTMENT 2.712 -11.665 0.000 0.000 3.785 2.413 12.213 9.749 0.000 0.271 0.697 0.000 -8.263 0.000 -11.912 -0.000
F6 SW APARTMENT 9.945 -10.778 0.000 0.000 3.811 2.413 12.213 14.608 0.000 0.334 0.000 0.000 -13.487 0.000 -17.387 -1.672
F6 NW APARTMENT 13.215 -7.814 0.000 0.000 3.846 2.413 12.213 7.806 0.000 0.332 0.000 0.000 -14.019 0.000 -16.808 -1.183
F6 SE APARTMENT 9.735 -10.846 0.000 0.000 3.817 2.413 12.213 14.604 0.000 0.332 0.000 0.000 -13.273 0.000 -17.408 -1.587
F6 NE APARTMENT 12.900 -7.880 0.000 0.000 3.855 2.413 12.213 7.714 0.000 0.322 0.000 0.000 -13.700 0.000 -16.788 -1.048
F6 N1 APARTMENT 5.426 -7.219 0.000 0.000 3.846 2.413 12.213 2.763 0.000 0.271 0.950 0.000 -8.839 0.000 -11.824 -0.000
F6 N2 APARTMENT 5.419 -7.216 0.000 0.000 3.846 2.413 12.213 2.763 0.000 0.270 0.951 0.000 -8.836 0.000 -11.823 -0.000
F6 S1 APARTMENT 3.199 -10.835 0.000 0.000 3.794 2.413 12.213 9.713 0.000 0.281 0.000 0.000 -8.276 0.000 -12.494 -0.008
F6 S2 APARTMENT 3.198 -10.830 0.000 0.000 3.794 2.413 12.213 9.711 0.000 0.282 0.000 0.000 -8.274 0.000 -12.498 -0.009
F7 SW APARTMENT 10.718 -10.301 0.000 0.000 3.818 2.413 12.213 14.552 0.000 0.346 0.000 0.000 -13.519 0.000 -18.182 -2.057
F7 NW APARTMENT 14.069 -7.486 0.000 0.000 3.852 2.413 12.213 7.784 0.000 0.344 0.000 0.000 -14.061 0.000 -17.582 -1.545
F7 SE APARTMENT 10.502 -10.363 0.000 0.000 3.824 2.413 12.213 14.551 0.000 0.344 0.000 0.000 -13.302 0.000 -18.206 -1.975
F7 NE APARTMENT 13.743 -7.552 0.000 0.000 3.861 2.413 12.213 7.696 0.000 0.332 0.000 0.000 -13.738 0.000 -17.559 -1.409
F7 N1 APARTMENT 5.947 -6.891 0.000 0.000 3.852 2.413 12.213 2.760 0.000 0.280 0.611 0.000 -8.862 0.000 -12.323 -0.000
F7 N2 APARTMENT 5.942 -6.891 0.000 0.000 3.853 2.413 12.213 2.759 0.000 0.279 0.613 0.000 -8.859 0.000 -12.321 -0.000
F7 S1 APARTMENT 3.602 -10.322 0.000 0.000 3.801 2.413 12.213 9.676 0.000 0.290 0.000 0.000 -8.292 0.000 -13.013 -0.368
F7 S2 APARTMENT 3.600 -10.316 0.000 0.000 3.802 2.413 12.213 9.675 0.000 0.291 0.001 0.000 -8.291 0.000 -13.017 -0.369
F8 SW APARTMENT 11.479 -9.938 0.000 0.000 3.823 2.413 12.213 14.504 0.000 0.359 0.000 0.000 -13.548 0.000 -18.921 -2.384
F8 NW APARTMENT 14.898 -7.260 0.000 0.000 3.857 2.413 12.213 7.764 0.000 0.356 0.000 0.000 -14.099 0.000 -18.301 -1.841
F8 SE APARTMENT 11.254 -9.996 0.000 0.000 3.829 2.413 12.213 14.506 0.000 0.356 0.000 0.000 -13.328 0.000 -18.946 -2.300
F8 NE APARTMENT 14.565 -7.327 0.000 0.000 3.867 2.413 12.213 7.679 0.000 0.344 0.000 0.000 -13.773 0.000 -18.278 -1.702
F8 N1 APARTMENT 6.480 -6.662 0.000 0.000 3.858 2.413 12.213 2.756 0.000 0.289 0.330 0.000 -8.882 0.000 -12.795 -0.000
F8 N2 APARTMENT 6.472 -6.659 0.000 0.000 3.859 2.413 12.213 2.755 0.000 0.288 0.333 0.000 -8.880 0.000 -12.793 -0.000
F8 S1 APARTMENT 4.021 -9.916 0.000 0.000 3.808 2.413 12.213 9.646 0.000 0.300 0.000 0.000 -8.306 0.000 -13.502 -0.677
F8 S2 APARTMENT 4.018 -9.909 0.000 0.000 3.808 2.413 12.213 9.644 0.000 0.300 0.000 0.000 -8.305 0.000 -13.506 -0.676
F9 SW APARTMENT 12.963 -9.656 0.000 0.000 3.830 2.413 12.213 14.478 0.000 0.377 0.000 0.000 -13.539 0.000 -19.581 -3.499
F9 NW APARTMENT 16.524 -7.170 0.000 0.000 3.862 2.413 12.213 7.756 0.000 0.375 0.000 0.000 -14.101 0.000 -18.952 -2.919
F9 SE APARTMENT 12.711 -9.693 0.000 0.000 3.836 2.413 12.213 14.482 0.000 0.374 0.000 0.000 -13.318 0.000 -19.613 -3.406
F9 NE APARTMENT 16.153 -7.226 0.000 0.000 3.872 2.413 12.213 7.673 0.000 0.360 0.000 0.000 -13.773 0.000 -18.927 -2.757
F9 N1 APARTMENT 7.696 -6.488 0.000 0.000 3.864 2.413 12.213 2.757 0.000 0.307 0.000 0.000 -8.878 0.000 -13.222 -0.662
F9 N2 APARTMENT 7.689 -6.487 0.000 0.000 3.864 2.413 12.213 2.756 0.000 0.305 0.000 0.000 -8.875 0.000 -13.220 -0.658
F9 S1 APARTMENT 4.974 -9.477 0.000 0.000 3.817 2.413 12.213 9.631 0.000 0.316 0.000 0.000 -8.294 0.000 -13.935 -1.656
F9 S2 APARTMENT 4.974 -9.476 0.000 0.000 3.817 2.413 12.213 9.629 0.000 0.316 0.000 0.000 -8.293 0.000 -13.940 -1.653
T SW APARTMENT 19.007 -9.483 0.000 0.000 3.860 2.413 12.213 14.293 0.000 0.387 0.000 0.000 -13.048 0.000 -20.112 -9.529
T NW APARTMENT 22.178 -7.139 0.000 0.000 3.883 2.413 12.213 7.614 0.000 0.382 0.000 0.000 -13.658 0.000 -19.523 -8.363
T SE APARTMENT 18.701 -9.380 0.000 0.000 3.866 2.413 12.213 14.320 0.000 0.386 0.000 0.000 -12.853 0.000 -20.148 -9.518
T NE APARTMENT 21.719 -7.036 0.000 0.000 3.894 2.413 12.213 7.556 0.000 0.371 0.000 0.000 -13.354 0.000 -19.503 -8.271
T N1 APARTMENT 12.709 -6.173 0.000 0.000 3.886 2.413 12.213 2.717 0.000 0.309 0.000 0.000 -8.577 0.000 -13.567 -5.930
T N2 APARTMENT 12.705 -6.165 0.000 0.000 3.887 2.413 12.213 2.714 0.000 0.309 0.000 0.000 -8.574 0.000 -13.571 -5.932
T S1 APARTMENT 9.988 -8.648 0.000 0.000 3.847 2.413 12.213 9.534 0.000 0.334 0.000 0.000 -8.027 0.000 -14.281 -7.372
T S2 APARTMENT 9.992 -8.651 0.000 0.000 3.847 2.413 12.213 9.530 0.000 0.334 0.000 0.000 -8.024 0.000 -14.289 -7.365
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 3.666 0.000 0.227 30.513 0.000 -2.755 0.000 -50.181 -0.001
F2 CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 1.638 0.000 0.003 0.000 0.000 -1.675 0.000 -1.412 -17.083
F3 CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 1.596 0.000 0.004 0.000 0.000 -1.745 0.000 -1.711 -16.672
F4 CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 1.573 0.000 0.004 0.000 0.000 -1.780 0.000 -1.930 -16.396
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 37.059 0.000 1.545 0.000 0.003 0.000 0.000 -1.831 0.000 -2.180 -34.596
F6 CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 1.556 0.000 0.004 0.000 0.000 -1.799 0.000 -2.235 -16.055
F7 CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 1.556 0.000 0.005 0.000 0.000 -1.792 0.000 -2.342 -15.956
F8 CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 1.553 0.000 0.005 0.000 0.000 -1.791 0.000 -2.446 -15.850
F9 CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 1.552 0.000 0.005 0.000 0.000 -1.786 0.000 -2.533 -15.767
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 7.937 1.513 0.000 0.001 0.000 0.000 -1.737 0.000 -2.663 -23.581
Total Facility 680.536 -698.911 0.000 0.000 303.716 416.414 980.287 723.622 0.000 22.584 41.008 0.000 -888.216 0.000 -1155.499 -425.540


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 21-SEP-15:30 0.00 -2617.18 0.00 0.00 48.90 100.83 470.89 3724.24 0.00 150.81 0.00 0.00 0.00 0.00 0.00 -1878.50
G NW APARTMENT 10-JUL-18:30 0.00 -2173.62 0.00 0.00 141.83 230.46 547.42 2433.10 0.00 225.29 0.00 0.00 0.00 0.00 0.00 -1404.47
OFFICE 21-SEP-13:15 0.00 -3025.35 0.00 0.00 65.20 1622.33 544.91 3180.43 0.00 6.48 0.00 0.00 0.00 0.00 0.00 -2393.99
G NE APARTMENT 05-AUG-09:45 0.00 -1598.44 0.00 0.00 40.76 28.81 406.15 2269.38 0.00 262.41 0.00 0.00 0.00 0.00 0.00 -1409.06
G N1 APARTMENT 08-AUG-18:15 0.00 -1188.90 0.00 0.00 141.82 230.46 547.42 325.97 0.00 255.53 0.00 0.00 0.00 0.00 0.00 -312.30
G N2 APARTMENT 05-AUG-17:45 0.00 -1176.23 0.00 0.00 141.81 194.45 588.62 188.33 0.00 279.83 0.00 0.00 0.00 0.00 0.00 -216.80
G S1 APARTMENT 21-SEP-14:30 0.00 -1730.89 0.00 0.00 40.44 50.41 400.26 2308.37 0.00 120.70 0.00 0.00 0.00 0.00 0.00 -1189.30
G S2 APARTMENT 21-SEP-14:30 0.00 -1788.02 0.00 0.00 40.53 50.41 400.26 2308.07 0.00 124.49 0.00 0.00 0.00 0.00 0.00 -1135.74
F2 SW APARTMENT 21-SEP-15:30 0.00 -3288.98 0.00 0.00 48.90 100.83 470.89 3690.79 0.00 168.03 0.00 0.00 0.00 0.00 0.00 -1190.46
F2 NW APARTMENT 10-JUL-18:30 0.00 -2789.84 0.00 0.00 141.83 230.46 547.42 2396.16 0.00 271.58 0.00 0.00 0.00 0.00 0.00 -797.61
F2 SE APARTMENT 21-SEP-14:15 0.00 -2863.18 0.00 0.00 40.75 50.41 400.26 2666.33 0.00 155.28 0.00 0.00 0.00 0.00 0.00 -449.86
F2 NE APARTMENT 05-AUG-09:45 0.00 -2124.36 0.00 0.00 40.76 28.81 406.15 2239.12 0.00 324.54 0.00 0.00 0.00 0.00 0.00 -915.02
F2 N1 APARTMENT 25-JUL-18:15 0.00 -1647.53 0.00 0.00 141.82 230.46 547.42 553.63 0.00 373.72 0.00 0.00 0.00 0.00 0.00 -199.51
F2 N2 APARTMENT 25-JUL-18:15 0.00 -1632.05 0.00 0.00 141.82 230.46 547.42 553.97 0.00 373.83 0.00 0.00 0.00 0.00 0.00 -215.44
F2 S1 APARTMENT 21-SEP-14:30 0.00 -2281.18 0.00 0.00 40.51 50.41 400.26 2278.52 0.00 146.98 0.00 0.00 0.00 0.00 0.00 -635.50
F2 S2 APARTMENT 21-SEP-14:30 0.00 -2303.81 0.00 0.00 40.54 50.41 400.26 2278.49 0.00 148.73 0.00 0.00 0.00 0.00 0.00 -614.62
F3 SW APARTMENT 21-SEP-15:30 0.00 -3320.88 0.00 0.00 48.90 100.83 470.89 3671.75 0.00 178.93 0.00 0.00 0.00 0.00 0.00 -1150.42
F3 NW APARTMENT 25-JUL-17:45 0.00 -2959.49 0.00 0.00 141.83 194.45 588.62 2415.39 0.00 530.19 0.00 0.00 0.00 0.00 0.00 -910.99
F3 SE APARTMENT 08-AUG-12:00 0.00 -2816.07 0.00 0.00 40.76 28.81 406.15 2721.10 0.00 407.35 0.00 0.00 0.00 0.00 0.00 -788.09
F3 NE APARTMENT 06-AUG-18:00 0.00 -2230.23 0.00 0.00 141.82 194.45 588.62 357.89 0.00 583.29 364.16 0.00 0.00 0.00 0.00 0.00
F3 N1 APARTMENT 08-AUG-18:00 0.00 -1759.62 0.00 0.00 141.82 194.45 588.62 308.87 0.00 423.53 102.33 0.00 0.00 0.00 0.00 0.00
F3 N2 APARTMENT 08-AUG-18:00 0.00 -1744.82 0.00 0.00 141.82 194.45 588.62 309.13 0.00 423.23 87.57 0.00 0.00 0.00 0.00 0.00
F3 S1 APARTMENT 21-SEP-14:30 0.00 -2330.42 0.00 0.00 40.50 50.41 400.26 2262.14 0.00 161.32 0.00 0.00 0.00 0.00 0.00 -584.21
F3 S2 APARTMENT 21-SEP-14:30 0.00 -2342.12 0.00 0.00 40.51 50.41 400.26 2262.10 0.00 162.29 0.00 0.00 0.00 0.00 0.00 -573.46
F4 SW APARTMENT 21-SEP-15:30 0.00 -3332.56 0.00 0.00 48.90 100.83 470.89 3657.42 0.00 187.01 0.00 0.00 0.00 0.00 0.00 -1132.50
F4 NW APARTMENT 25-JUL-17:45 0.00 -3009.64 0.00 0.00 141.83 194.45 588.62 2401.52 0.00 578.35 0.00 0.00 0.00 0.00 0.00 -895.13
F4 SE APARTMENT 08-AUG-12:00 0.00 -2846.37 0.00 0.00 40.76 28.81 406.15 2709.47 0.00 439.33 0.00 0.00 0.00 0.00 0.00 -778.14
F4 NE APARTMENT 06-AUG-18:00 0.00 -2293.81 0.00 0.00 141.82 194.45 588.62 355.82 0.00 638.14 374.96 0.00 0.00 0.00 0.00 0.00
F4 N1 APARTMENT 08-AUG-18:00 0.00 -1786.61 0.00 0.00 141.82 194.45 588.62 307.90 0.00 455.48 98.33 0.00 0.00 0.00 0.00 0.00
F4 N2 APARTMENT 08-AUG-18:00 0.00 -1771.83 0.00 0.00 141.82 194.45 588.62 308.17 0.00 455.16 83.62 0.00 0.00 0.00 0.00 0.00
F4 S1 APARTMENT 21-SEP-14:30 0.00 -2348.69 0.00 0.00 40.49 50.41 400.26 2250.29 0.00 171.74 0.00 0.00 0.00 0.00 0.00 -564.51
F4 S2 APARTMENT 21-SEP-14:30 0.00 -2358.82 0.00 0.00 40.51 50.41 400.26 2250.25 0.00 172.66 0.00 0.00 0.00 0.00 0.00 -555.27
M SW APARTMENT 21-SEP-15:30 0.00 -3356.52 0.00 0.00 48.90 100.83 470.89 3645.17 0.00 193.37 0.00 0.00 0.00 0.00 0.00 -1102.63
M NW APARTMENT 25-JUL-17:30 0.00 -3070.34 0.00 0.00 141.82 194.45 588.62 2488.65 0.00 622.69 0.00 0.00 0.00 0.00 0.00 -965.89
M SE APARTMENT 08-AUG-12:00 0.00 -2895.61 0.00 0.00 40.76 28.81 406.15 2699.43 0.00 465.01 0.00 0.00 0.00 0.00 0.00 -744.54
M NE APARTMENT 06-AUG-18:00 0.00 -2358.85 0.00 0.00 141.82 194.45 588.62 353.52 0.00 680.57 399.86 0.00 0.00 0.00 0.00 0.00
M N1 APARTMENT 08-AUG-18:00 0.00 -1832.07 0.00 0.00 141.82 194.45 588.62 306.61 0.00 481.32 119.25 0.00 0.00 0.00 0.00 0.00
M N2 APARTMENT 08-AUG-18:00 0.00 -1817.31 0.00 0.00 141.82 194.45 588.62 306.87 0.00 480.97 104.58 0.00 0.00 0.00 0.00 0.00
M S1 APARTMENT 21-SEP-14:30 0.00 -2386.77 0.00 0.00 40.52 50.41 400.26 2240.68 0.00 181.63 0.00 0.00 0.00 0.00 0.00 -526.74
M S2 APARTMENT 21-SEP-14:30 0.00 -2396.65 0.00 0.00 40.54 50.41 400.26 2240.64 0.00 182.58 0.00 0.00 0.00 0.00 0.00 -517.77
F6 SW APARTMENT 21-SEP-15:30 0.00 -3307.83 0.00 0.00 48.90 100.83 470.89 3636.45 0.00 198.51 0.00 0.00 0.00 0.00 0.00 -1147.76
F6 NW APARTMENT 25-JUL-17:30 0.00 -3049.20 0.00 0.00 141.82 194.45 588.62 2480.89 0.00 653.85 0.00 0.00 0.00 0.00 0.00 -1010.44
F6 SE APARTMENT 08-AUG-12:00 0.00 -2874.89 0.00 0.00 40.76 28.81 406.15 2692.95 0.00 486.41 0.00 0.00 0.00 0.00 0.00 -780.18
F6 NE APARTMENT 06-AUG-11:00 0.00 -2347.64 0.00 0.00 40.76 28.81 412.03 1320.55 0.00 813.38 0.00 0.00 0.00 0.00 0.00 -267.88
F6 N1 APARTMENT 08-AUG-18:00 0.00 -1803.41 0.00 0.00 141.82 194.45 588.62 306.77 0.00 501.55 70.21 0.00 0.00 0.00 0.00 0.00
F6 N2 APARTMENT 08-AUG-18:00 0.00 -1788.74 0.00 0.00 141.82 194.45 588.62 307.03 0.00 501.17 55.65 0.00 0.00 0.00 0.00 0.00
F6 S1 APARTMENT 21-SEP-14:30 0.00 -2349.91 0.00 0.00 40.55 50.41 400.26 2233.77 0.00 189.56 0.00 0.00 0.00 0.00 0.00 -564.64
F6 S2 APARTMENT 21-SEP-14:30 0.00 -2359.80 0.00 0.00 40.56 50.41 400.26 2233.73 0.00 190.52 0.00 0.00 0.00 0.00 0.00 -555.68
F7 SW APARTMENT 21-SEP-15:30 0.00 -3281.61 0.00 0.00 48.90 100.83 470.89 3628.26 0.00 202.74 0.00 0.00 0.00 0.00 0.00 -1170.01
F7 NW APARTMENT 25-JUL-17:30 0.00 -3042.74 0.00 0.00 141.82 194.45 588.62 2473.73 0.00 678.99 0.00 0.00 0.00 0.00 0.00 -1034.87
F7 SE APARTMENT 08-AUG-12:00 0.00 -2875.17 0.00 0.00 40.76 28.81 406.15 2686.78 0.00 504.64 0.00 0.00 0.00 0.00 0.00 -791.97
F7 NE APARTMENT 06-AUG-11:00 0.00 -2344.59 0.00 0.00 40.76 28.81 412.03 1316.80 0.00 843.96 0.00 0.00 0.00 0.00 0.00 -297.76
F7 N1 APARTMENT 08-AUG-18:00 0.00 -1799.59 0.00 0.00 141.82 194.45 588.62 306.43 0.00 519.02 49.24 0.00 0.00 0.00 0.00 0.00
F7 N2 APARTMENT 08-AUG-18:00 0.00 -1784.98 0.00 0.00 141.82 194.45 588.62 306.70 0.00 518.62 34.77 0.00 0.00 0.00 0.00 0.00
F7 S1 APARTMENT 21-SEP-14:30 0.00 -2338.90 0.00 0.00 40.58 50.41 400.26 2227.53 0.00 197.12 0.00 0.00 0.00 0.00 0.00 -577.00
F7 S2 APARTMENT 21-SEP-14:30 0.00 -2348.81 0.00 0.00 40.59 50.41 400.26 2227.49 0.00 198.09 0.00 0.00 0.00 0.00 0.00 -568.03
F8 SW APARTMENT 21-SEP-15:30 0.00 -3259.67 0.00 0.00 48.90 100.83 470.89 3620.85 0.00 206.24 0.00 0.00 0.00 0.00 0.00 -1188.05
F8 NW APARTMENT 25-JUL-17:30 0.00 -3049.54 0.00 0.00 141.82 194.45 588.62 2467.19 0.00 701.30 0.00 0.00 0.00 0.00 0.00 -1043.84
F8 SE APARTMENT 08-AUG-12:00 0.00 -2883.73 0.00 0.00 40.76 28.81 406.15 2681.08 0.00 520.42 0.00 0.00 0.00 0.00 0.00 -793.48
F8 NE APARTMENT 06-AUG-11:15 0.00 -2359.53 0.00 0.00 40.69 28.81 406.15 1190.79 0.00 866.77 0.00 0.00 0.00 0.00 0.00 -173.67
F8 N1 APARTMENT 08-AUG-18:00 0.00 -1809.32 0.00 0.00 141.82 194.45 588.62 305.85 0.00 534.64 43.94 0.00 0.00 0.00 0.00 0.00
F8 N2 APARTMENT 08-AUG-18:00 0.00 -1794.79 0.00 0.00 141.82 194.45 588.62 306.11 0.00 534.22 29.57 0.00 0.00 0.00 0.00 0.00
F8 S1 APARTMENT 21-SEP-14:30 0.00 -2341.05 0.00 0.00 40.64 50.41 400.26 2222.11 0.00 205.38 0.00 0.00 0.00 0.00 0.00 -577.75
F8 S2 APARTMENT 21-SEP-14:30 0.00 -2350.98 0.00 0.00 40.65 50.41 400.26 2222.06 0.00 206.35 0.00 0.00 0.00 0.00 0.00 -568.76
F9 SW APARTMENT 17-AUG-17:15 0.00 -3310.80 0.00 0.00 141.81 194.45 588.62 2152.62 0.00 463.67 0.00 0.00 0.00 0.00 0.00 -230.38
F9 NW APARTMENT 25-JUL-17:30 0.00 -3139.48 0.00 0.00 141.82 194.45 588.62 2459.38 0.00 726.71 0.00 0.00 0.00 0.00 0.00 -971.51
F9 SE APARTMENT 08-AUG-12:15 0.00 -2931.28 0.00 0.00 40.76 28.81 388.49 2646.90 0.00 528.43 0.00 0.00 0.00 0.00 0.00 -702.10
F9 NE APARTMENT 06-AUG-11:15 0.00 -2397.16 0.00 0.00 40.70 28.81 406.15 1187.79 0.00 893.31 0.00 0.00 0.00 0.00 0.00 -159.60
F9 N1 APARTMENT 08-AUG-18:00 0.00 -1894.53 0.00 0.00 141.82 194.45 588.62 303.66 0.00 551.58 114.40 0.00 0.00 0.00 0.00 0.00
F9 N2 APARTMENT 08-AUG-18:00 0.00 -1879.82 0.00 0.00 141.82 194.45 588.62 303.92 0.00 551.13 99.87 0.00 0.00 0.00 0.00 0.00
F9 S1 APARTMENT 21-SEP-14:30 0.00 -2377.45 0.00 0.00 40.75 50.41 400.26 2217.24 0.00 216.76 0.00 0.00 0.00 0.00 0.00 -547.97
F9 S2 APARTMENT 21-SEP-14:15 0.00 -2383.72 0.00 0.00 40.75 50.41 400.26 2352.17 0.00 206.05 0.00 0.00 0.00 0.00 0.00 -665.93
T SW APARTMENT 21-SEP-15:15 0.00 -3943.83 0.00 0.00 48.90 100.83 470.89 3673.86 0.00 228.66 0.00 0.00 0.00 0.00 0.00 -579.32
T NW APARTMENT 25-JUL-17:30 0.00 -3597.43 0.00 0.00 141.82 194.45 588.62 2421.89 0.00 745.33 0.00 0.00 0.00 0.00 0.00 -494.68
T SE APARTMENT 17-AUG-11:15 0.00 -3581.46 0.00 0.00 40.75 28.81 406.15 2932.64 0.00 375.05 0.00 0.00 0.00 0.00 0.00 -201.93
T NE APARTMENT 06-AUG-11:00 0.00 -2775.65 0.00 0.00 40.76 28.81 412.03 1280.24 0.00 930.54 83.27 0.00 0.00 0.00 0.00 0.00
T N1 APARTMENT 17-AUG-17:08 0.00 -2230.20 0.00 0.00 141.81 194.45 588.62 266.31 0.00 552.70 486.31 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 25-JUL-17:00 0.00 -2219.63 0.00 0.00 84.76 144.04 588.62 321.96 0.00 723.60 356.65 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 08-AUG-12:15 0.00 -3028.57 0.00 0.00 40.76 28.81 388.49 2249.95 0.00 511.67 0.00 0.00 0.00 0.00 0.00 -191.10
T S2 APARTMENT 08-AUG-12:15 0.00 -3048.91 0.00 0.00 40.75 28.81 388.49 2249.52 0.00 511.54 0.00 0.00 0.00 0.00 0.00 -170.19
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 17-AUG-17:15 0.00 -179787.44 0.00 0.00 11203.10 22204.40 47141.46 66734.25 0.00 34147.27 0.00 0.00 0.00 0.00 -42.26 -1600.79


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 06-FEB-09:30 2214.09 0.00 0.00 0.00 47.42 28.81 394.37 0.00 0.00 0.00 0.00 0.00 -1050.85 0.00 -874.44 -759.40
G NW APARTMENT 07-FEB-08:30 2378.88 0.00 0.00 0.00 73.97 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -1131.65 0.00 -803.87 -949.04
OFFICE 13-FEB-08:00 2219.28 0.00 0.00 0.00 0.00 379.58 194.98 0.00 0.00 0.00 0.00 0.00 -1132.25 0.00 -935.70 -725.89
G NE APARTMENT 06-FEB-10:00 2256.94 0.00 0.00 0.00 47.42 28.81 394.37 0.00 0.00 0.00 0.00 0.00 -835.97 0.00 -963.68 -927.88
G N1 APARTMENT 28-SEP-14:00 1862.73 0.00 0.00 0.00 42.05 28.81 382.60 0.00 0.00 0.00 0.00 0.00 -89.40 0.00 -1647.71 -579.08
G N2 APARTMENT 28-SEP-14:00 1891.72 0.00 0.00 0.00 42.10 28.81 382.60 0.00 0.00 0.00 0.00 0.00 -88.95 0.00 -1646.80 -609.47
G S1 APARTMENT 10-NOV-10:55 1762.18 0.00 0.00 0.00 46.83 28.81 406.15 188.86 0.00 0.00 0.00 0.00 0.00 0.00 -1799.90 -632.93
G S2 APARTMENT 10-NOV-10:55 1808.00 0.00 0.00 0.00 46.67 28.81 406.15 186.91 0.00 0.00 0.00 0.00 0.00 0.00 -1800.19 -676.34
F2 SW APARTMENT 10-NOV-10:55 2508.45 0.00 0.00 0.00 46.46 28.81 406.15 236.50 0.00 0.00 0.00 0.00 0.00 0.00 -2510.93 -715.43
F2 NW APARTMENT 06-FEB-10:00 2523.21 0.00 0.00 0.00 47.42 28.81 394.37 0.00 0.00 0.00 0.00 0.00 -991.65 0.00 -1385.63 -616.53
F2 SE APARTMENT 10-NOV-10:55 2514.47 0.00 0.00 0.00 46.40 28.81 406.15 252.66 0.00 0.00 0.00 0.00 0.00 0.00 -2510.87 -737.62
F2 NE APARTMENT 06-FEB-10:00 2478.27 0.00 0.00 0.00 47.42 28.81 394.37 0.00 0.00 0.00 0.00 0.00 -898.56 0.00 -1385.63 -664.67
F2 N1 APARTMENT 10-NOV-10:55 2345.96 0.00 0.00 0.00 46.79 28.81 406.15 118.36 0.00 0.00 0.00 0.00 0.00 0.00 -2409.06 -537.00
F2 N2 APARTMENT 10-NOV-10:55 2340.07 0.00 0.00 0.00 46.81 28.81 406.15 118.52 0.00 0.00 0.00 0.00 0.00 0.00 -2409.02 -531.33
F2 S1 APARTMENT 10-NOV-10:55 2641.92 0.00 0.00 0.00 45.71 28.81 406.15 159.55 0.00 0.00 0.00 0.00 0.00 0.00 -2411.47 -870.67
F2 S2 APARTMENT 10-NOV-10:55 2649.21 0.00 0.00 0.00 45.67 28.81 406.15 159.21 0.00 0.00 0.00 0.00 0.00 0.00 -2411.58 -877.47
F3 SW APARTMENT 10-NOV-10:55 2883.01 0.00 0.00 0.00 46.50 28.81 406.15 223.22 0.00 0.00 0.00 0.00 0.00 0.00 -2918.85 -668.84
F3 NW APARTMENT 06-FEB-10:00 2714.08 0.00 0.00 0.00 47.42 28.81 394.37 0.00 0.00 0.00 0.00 0.00 -1019.27 0.00 -1641.07 -524.34
F3 SE APARTMENT 10-NOV-10:55 2786.12 0.00 0.00 0.00 46.79 28.81 406.15 246.72 0.00 0.00 0.00 0.00 0.00 0.00 -2917.35 -597.23
F3 NE APARTMENT 06-FEB-10:00 2666.45 0.00 0.00 0.00 47.42 28.81 394.37 0.00 0.00 0.00 0.00 0.00 -923.31 0.00 -1641.07 -572.68
F3 N1 APARTMENT 10-NOV-10:55 2755.71 0.00 0.00 0.00 46.66 28.81 406.15 111.18 0.00 0.00 0.00 0.00 0.00 0.00 -2798.63 -549.88
F3 N2 APARTMENT 10-NOV-10:55 2749.57 0.00 0.00 0.00 46.68 28.81 406.15 111.36 0.00 0.00 0.00 0.00 0.00 0.00 -2798.59 -543.98
F3 S1 APARTMENT 10-NOV-10:55 3096.78 0.00 0.00 0.00 45.53 28.81 406.15 149.11 0.00 0.00 0.00 0.00 0.00 0.00 -2801.28 -925.08
F3 S2 APARTMENT 10-NOV-10:55 3095.06 0.00 0.00 0.00 45.53 28.81 406.15 149.20 0.00 0.00 0.00 0.00 0.00 0.00 -2801.31 -923.43
F4 SW APARTMENT 13-FEB-06:00 2806.92 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -1382.30 0.00 -1918.32 -42.71
F4 NW APARTMENT 06-FEB-10:00 2900.85 0.00 0.00 0.00 47.42 28.81 394.37 0.00 0.00 0.00 0.00 0.00 -1036.34 0.00 -1834.91 -500.19
F4 SE APARTMENT 13-FEB-06:00 2793.00 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -1361.64 0.00 -1918.32 -49.44
F4 NE APARTMENT 06-FEB-10:00 2851.56 0.00 0.00 0.00 47.42 28.81 394.37 0.00 0.00 0.00 0.00 0.00 -938.69 0.00 -1834.92 -548.56
F4 N1 APARTMENT 25-OCT-13:40 2311.99 0.00 0.00 0.00 45.68 28.81 382.60 230.97 0.00 0.00 0.00 0.00 0.00 0.00 -2023.40 -976.65
F4 N2 APARTMENT 25-OCT-13:40 2313.11 0.00 0.00 0.00 45.68 28.81 382.60 230.90 0.00 0.00 0.00 0.00 0.00 0.00 -2023.37 -977.73
F4 S1 APARTMENT 13-FEB-04:00 1456.14 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 87.40 0.00 -834.92 0.00 -1136.38 0.00
F4 S2 APARTMENT 13-FEB-04:00 1455.66 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 87.91 0.00 -834.94 0.00 -1136.38 0.00
M SW APARTMENT 13-FEB-06:00 2954.66 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -1392.59 0.00 -2085.68 -12.79
M NW APARTMENT 06-FEB-10:00 3042.25 0.00 0.00 0.00 47.42 28.81 394.37 0.00 0.00 0.00 0.00 0.00 -1049.98 0.00 -1994.81 -468.06
M SE APARTMENT 13-FEB-06:00 2940.27 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -1371.20 0.00 -2085.68 -19.79
M NE APARTMENT 13-FEB-06:00 2993.30 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -1367.08 0.00 -2085.68 -76.94
M N1 APARTMENT 25-OCT-13:40 2477.41 0.00 0.00 0.00 45.64 28.81 382.60 227.87 0.00 0.00 0.00 0.00 0.00 0.00 -2178.17 -984.17
M N2 APARTMENT 25-OCT-13:40 2480.26 0.00 0.00 0.00 45.64 28.81 382.60 227.79 0.00 0.00 0.00 0.00 0.00 0.00 -2178.14 -986.96
M S1 APARTMENT 16-NOV-10:15 2026.18 0.00 0.00 0.00 41.20 28.81 406.15 427.84 0.00 0.00 0.00 0.00 0.00 0.00 -2242.30 -687.87
M S2 APARTMENT 16-NOV-10:15 1976.14 0.00 0.00 0.00 41.21 28.81 406.15 428.03 0.00 0.00 0.00 0.00 0.00 0.00 -2242.97 -637.37
F6 SW APARTMENT 13-FEB-06:00 3141.47 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -1398.38 0.00 -2230.06 -49.43
F6 NW APARTMENT 06-FEB-10:00 3222.57 0.00 0.00 0.00 47.42 28.81 394.37 0.00 0.00 0.00 0.00 0.00 -1058.34 0.00 -2132.70 -502.13
F6 SE APARTMENT 13-FEB-06:00 3126.67 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -1376.50 0.00 -2230.06 -56.51
F6 NE APARTMENT 13-FEB-06:00 3178.89 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -1372.48 0.00 -2230.06 -112.75
F6 N1 APARTMENT 25-OCT-13:40 2505.94 0.00 0.00 0.00 45.95 28.81 382.60 228.97 0.00 0.00 0.00 0.00 0.00 0.00 -2314.05 -878.21
F6 N2 APARTMENT 25-OCT-13:40 2505.31 0.00 0.00 0.00 45.95 28.81 382.60 228.87 0.00 0.00 0.00 0.00 0.00 0.00 -2314.03 -877.51
F6 S1 APARTMENT 16-NOV-10:15 2225.86 0.00 0.00 0.00 41.61 28.81 406.15 427.98 0.00 0.00 0.00 0.00 0.00 0.00 -2374.25 -756.15
F6 S2 APARTMENT 16-NOV-10:15 2203.56 0.00 0.00 0.00 41.63 28.81 406.15 428.22 0.00 0.00 0.00 0.00 0.00 0.00 -2374.26 -734.09
F7 SW APARTMENT 13-FEB-06:00 3292.57 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -1403.73 0.00 -2358.12 -67.12
F7 NW APARTMENT 06-FEB-10:00 3365.99 0.00 0.00 0.00 47.42 28.81 394.37 0.00 0.00 0.00 0.00 0.00 -1066.10 0.00 -2254.95 -515.53
F7 SE APARTMENT 13-FEB-06:00 3277.46 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -1381.46 0.00 -2358.12 -74.28
F7 NE APARTMENT 13-FEB-06:00 3327.24 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -1377.54 0.00 -2358.12 -127.98
F7 N1 APARTMENT 25-OCT-13:40 2552.66 0.00 0.00 0.00 46.14 28.81 382.60 229.27 0.00 0.00 0.00 0.00 0.00 0.00 -2437.09 -802.38
F7 N2 APARTMENT 25-OCT-13:40 2553.22 0.00 0.00 0.00 46.14 28.81 382.60 229.16 0.00 0.00 0.00 0.00 0.00 0.00 -2437.07 -802.85
F7 S1 APARTMENT 16-NOV-10:15 2240.68 0.00 0.00 0.00 41.94 28.81 406.15 427.83 0.00 0.00 0.00 0.00 0.00 0.00 -2497.77 -647.63
F7 S2 APARTMENT 16-NOV-10:15 2271.21 0.00 0.00 0.00 41.95 28.81 406.15 428.08 0.00 0.00 0.00 0.00 0.00 0.00 -2497.81 -678.39
F8 SW APARTMENT 13-FEB-06:00 3435.27 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -1408.10 0.00 -2473.90 -89.67
F8 NW APARTMENT 06-FEB-10:00 3502.29 0.00 0.00 0.00 47.42 28.81 394.37 0.00 0.00 0.00 0.00 0.00 -1072.91 0.00 -2365.45 -534.54
F8 SE APARTMENT 13-FEB-06:00 3420.02 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -1385.53 0.00 -2473.90 -96.98
F8 NE APARTMENT 13-FEB-06:00 3466.17 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -1381.73 0.00 -2473.91 -146.94
F8 N1 APARTMENT 27-NOV-09:15 2619.96 0.00 0.00 0.00 47.42 28.81 394.37 0.00 0.00 0.00 291.44 0.00 -44.40 0.00 -3337.60 0.00
F8 N2 APARTMENT 27-NOV-09:15 2622.12 0.00 0.00 0.00 47.42 28.81 394.37 0.00 0.00 0.00 289.21 0.00 -44.33 0.00 -3337.60 0.00
F8 S1 APARTMENT 16-NOV-10:15 2206.56 0.00 0.00 0.00 42.24 28.81 406.15 427.95 0.00 0.00 0.00 0.00 0.00 0.00 -2611.43 -500.27
F8 S2 APARTMENT 16-NOV-10:15 2215.76 0.00 0.00 0.00 42.25 28.81 406.15 428.21 0.00 0.00 0.00 0.00 0.00 0.00 -2611.45 -509.72
F9 SW APARTMENT 13-FEB-06:00 3672.60 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -1408.25 0.00 -2580.05 -220.70
F9 NW APARTMENT 06-FEB-10:00 3740.01 0.00 0.00 0.00 47.42 28.81 394.37 0.00 0.00 0.00 0.00 0.00 -1074.91 0.00 -2466.71 -668.99
F9 SE APARTMENT 13-FEB-06:00 3657.21 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -1385.49 0.00 -2580.05 -228.07
F9 NE APARTMENT 13-FEB-06:00 3693.89 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -1381.92 0.00 -2580.06 -268.31
F9 N1 APARTMENT 07-APR-09:10 2795.06 0.00 0.00 0.00 45.10 28.81 406.15 315.10 0.00 0.00 0.00 0.00 0.00 0.00 -2411.13 -1179.08
F9 N2 APARTMENT 27-NOV-09:15 2785.85 0.00 0.00 0.00 47.42 28.81 394.37 0.00 0.00 0.00 268.13 0.00 -44.59 0.00 -3479.99 0.00
F9 S1 APARTMENT 16-NOV-10:15 2139.23 0.00 0.00 0.00 42.85 28.81 406.15 432.40 0.00 0.00 0.00 0.00 0.00 0.00 -2716.97 -332.47
F9 S2 APARTMENT 16-NOV-10:15 2148.90 0.00 0.00 0.00 42.86 28.81 406.15 432.64 0.00 0.00 0.00 0.00 0.00 0.00 -2716.97 -342.38
T SW APARTMENT 13-FEB-06:00 4359.61 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -1379.13 0.00 -2678.20 -838.68
T NW APARTMENT 13-FEB-06:00 4377.29 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -1375.14 0.00 -2678.20 -860.34
T SE APARTMENT 13-FEB-06:00 4342.62 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -1356.85 0.00 -2678.20 -843.97
T NE APARTMENT 13-FEB-06:00 4360.59 0.00 0.00 0.00 189.67 93.62 253.11 0.00 0.00 0.00 0.00 0.00 -1352.90 0.00 -2678.21 -865.88
T N1 APARTMENT 27-NOV-09:15 3058.75 0.00 0.00 0.00 47.42 28.81 394.37 0.00 0.00 0.00 123.24 0.00 -39.02 0.00 -3613.57 0.00
T N2 APARTMENT 27-NOV-09:15 3059.68 0.00 0.00 0.00 47.42 28.81 394.37 0.00 0.00 0.00 122.27 0.00 -38.98 0.00 -3613.57 0.00
T S1 APARTMENT 13-FEB-04:00 2736.01 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 0.00 0.00 -832.62 0.00 -1586.68 -744.46
T S2 APARTMENT 13-FEB-04:00 2735.68 0.00 0.00 0.00 189.67 14.40 223.68 0.00 0.00 0.00 0.00 0.00 -832.63 0.00 -1586.68 -744.12
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 06-FEB-10:00 191925.64 0.00 0.00 0.00 3821.86 10361.29 32058.83 0.00 0.00 0.00 0.00 0.00 -62111.75 0.00 -133742.49 -42313.38



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:07

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:07

Sec1.1A-General Information

Data
Weather File Buffalo Niagara Intl AP NY USA TMY3 WMO#=725280
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 7836.48
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.50
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
F2 SW APARTMENT 88.25 88.25 0.00 168.00
F2 NW APARTMENT 88.25 88.25 0.00 168.00
F2 SE APARTMENT 88.25 88.25 0.00 168.00
F2 NE APARTMENT 88.25 88.25 0.00 168.00
F2 N1 APARTMENT 88.25 88.25 0.00 168.00
F2 N2 APARTMENT 88.25 88.25 0.00 168.00
F2 S1 APARTMENT 88.25 88.25 0.00 168.00
F2 S2 APARTMENT 88.25 88.25 0.00 168.00
F3 SW APARTMENT 88.25 88.25 0.00 168.00
F3 NW APARTMENT 88.25 88.25 0.00 168.00
F3 SE APARTMENT 88.25 88.25 0.00 168.00
F3 NE APARTMENT 88.25 88.25 0.00 168.00
F3 N1 APARTMENT 88.25 88.25 0.00 168.00
F3 N2 APARTMENT 88.25 88.25 0.00 168.00
F3 S1 APARTMENT 88.25 88.25 0.00 168.00
F3 S2 APARTMENT 88.25 88.25 0.00 168.00
F4 SW APARTMENT 88.25 88.25 0.00 168.00
F4 NW APARTMENT 88.25 88.25 0.00 168.00
F4 SE APARTMENT 88.25 88.25 0.00 168.00
F4 NE APARTMENT 88.25 88.25 0.00 168.00
F4 N1 APARTMENT 88.25 88.25 0.00 168.00
F4 N2 APARTMENT 88.25 88.25 0.00 168.00
F4 S1 APARTMENT 88.25 88.25 0.00 168.00
F4 S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
F6 SW APARTMENT 88.25 88.25 0.00 168.00
F6 NW APARTMENT 88.25 88.25 0.00 168.00
F6 SE APARTMENT 88.25 88.25 0.00 168.00
F6 NE APARTMENT 88.25 88.25 0.00 168.00
F6 N1 APARTMENT 88.25 88.25 0.00 168.00
F6 N2 APARTMENT 88.25 88.25 0.00 168.00
F6 S1 APARTMENT 88.25 88.25 0.00 168.00
F6 S2 APARTMENT 88.25 88.25 0.00 168.00
F7 SW APARTMENT 88.25 88.25 0.00 168.00
F7 NW APARTMENT 88.25 88.25 0.00 168.00
F7 SE APARTMENT 88.25 88.25 0.00 168.00
F7 NE APARTMENT 88.25 88.25 0.00 168.00
F7 N1 APARTMENT 88.25 88.25 0.00 168.00
F7 N2 APARTMENT 88.25 88.25 0.00 168.00
F7 S1 APARTMENT 88.25 88.25 0.00 168.00
F7 S2 APARTMENT 88.25 88.25 0.00 168.00
F8 SW APARTMENT 88.25 88.25 0.00 168.00
F8 NW APARTMENT 88.25 88.25 0.00 168.00
F8 SE APARTMENT 88.25 88.25 0.00 168.00
F8 NE APARTMENT 88.25 88.25 0.00 168.00
F8 N1 APARTMENT 88.25 88.25 0.00 168.00
F8 N2 APARTMENT 88.25 88.25 0.00 168.00
F8 S1 APARTMENT 88.25 88.25 0.00 168.00
F8 S2 APARTMENT 88.25 88.25 0.00 168.00
F9 SW APARTMENT 88.25 88.25 0.00 168.00
F9 NW APARTMENT 88.25 88.25 0.00 168.00
F9 SE APARTMENT 88.25 88.25 0.00 168.00
F9 NE APARTMENT 88.25 88.25 0.00 168.00
F9 N1 APARTMENT 88.25 88.25 0.00 168.00
F9 N2 APARTMENT 88.25 88.25 0.00 168.00
F9 S1 APARTMENT 88.25 88.25 0.00 168.00
F9 S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
G CORRIDOR 77.66 0.00 77.66 0.00
F2 CORRIDOR 77.66 0.00 77.66 0.00
F3 CORRIDOR 77.66 0.00 77.66 0.00
F4 CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
F6 CORRIDOR 77.66 0.00 77.66 0.00
F7 CORRIDOR 77.66 0.00 77.66 0.00
F8 CORRIDOR 77.66 0.00 77.66 0.00
F9 CORRIDOR 77.66 0.00 77.66 0.00
T CORRIDOR 77.66 0.00 77.66 0.00
Totals 7836.48 7059.89 776.58  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 139.25
Number of hours cooling loads not met 79.75
Number of hours not met 219.00


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 416.41 25049.15 0.00 0.00 0.00 0.00
Exterior Lighting 168.23 10720.10 0.00 0.00 0.00 0.00
Space Heating 292.18 0.00 1050.73 245225.97 0.00 0.00
Space Cooling 265.22 68352.22 0.00 0.00 0.00 0.00
Pumps 49.85 1621.88 0.00 0.00 0.00 0.00
Heat Rejection 11.44 2725.24 0.00 0.00 0.00 0.00
Fans-Interior 571.40 18118.97 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 0.00 0.00 1228.41 83981.72 0.00 0.00
Receptacle Equipment 1131.09 49704.83 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 2926.66   2279.14   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 1131.09 2926.66
Natural Gas 0.00 2279.14
Additional 0.00 0.00
Total 1131.09 5205.80


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 53.14
Space Heating 37.28
Space Cooling 33.84
Fans-Interior 72.92
Service Water Heating 0.00
Receptacle Equipment 144.34
Miscellaneous 31.95
Subtotal 373.47


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 134.08
Service Water Heating 156.76
Miscellaneous -0.00
Subtotal 290.84


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 8.00
Space Heating 25.80
Space Cooling 5.09
Fans-Interior 10.98
Service Water Heating 23.60
Receptacle Equipment 21.73
Miscellaneous 4.81



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:07

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.206405
G NW APARTMENT DIRECT AIR 0.190865
OFFICE DIRECT AIR 0.282588
G NE APARTMENT DIRECT AIR 0.140673
G N1 APARTMENT DIRECT AIR 0.097092
G N2 APARTMENT DIRECT AIR 0.095464
G S1 APARTMENT DIRECT AIR 0.127092
G S2 APARTMENT DIRECT AIR 0.132242
F2 SW APARTMENT DIRECT AIR 0.272745
F2 NW APARTMENT DIRECT AIR 0.250437
F2 SE APARTMENT DIRECT AIR 0.256530
F2 NE APARTMENT DIRECT AIR 0.193028
F2 N1 APARTMENT DIRECT AIR 0.136803
F2 N2 APARTMENT DIRECT AIR 0.135444
F2 S1 APARTMENT DIRECT AIR 0.172859
F2 S2 APARTMENT DIRECT AIR 0.174938
F3 SW APARTMENT DIRECT AIR 0.273783
F3 NW APARTMENT DIRECT AIR 0.252888
F3 SE APARTMENT DIRECT AIR 0.242640
F3 NE APARTMENT DIRECT AIR 0.196685
F3 N1 APARTMENT DIRECT AIR 0.140834
F3 N2 APARTMENT DIRECT AIR 0.139492
F3 S1 APARTMENT DIRECT AIR 0.176368
F3 S2 APARTMENT DIRECT AIR 0.177452
F4 SW APARTMENT DIRECT AIR 0.274269
F4 NW APARTMENT DIRECT AIR 0.253790
F4 SE APARTMENT DIRECT AIR 0.242054
F4 NE APARTMENT DIRECT AIR 0.197616
F4 N1 APARTMENT DIRECT AIR 0.142293
F4 N2 APARTMENT DIRECT AIR 0.140958
F4 S1 APARTMENT DIRECT AIR 0.177414
F4 S2 APARTMENT DIRECT AIR 0.178356
M SW APARTMENT DIRECT AIR 0.276911
M NW APARTMENT DIRECT AIR 0.256791
M SE APARTMENT DIRECT AIR 0.244887
M NE APARTMENT DIRECT AIR 0.200584
M N1 APARTMENT DIRECT AIR 0.145553
M N2 APARTMENT DIRECT AIR 0.144224
M S1 APARTMENT DIRECT AIR 0.180356
M S2 APARTMENT DIRECT AIR 0.181277
F6 SW APARTMENT DIRECT AIR 0.273192
F6 NW APARTMENT DIRECT AIR 0.253204
F6 SE APARTMENT DIRECT AIR 0.241516
F6 NE APARTMENT DIRECT AIR 0.197114
F6 N1 APARTMENT DIRECT AIR 0.142474
F6 N2 APARTMENT DIRECT AIR 0.141158
F6 S1 APARTMENT DIRECT AIR 0.176976
F6 S2 APARTMENT DIRECT AIR 0.177894
F7 SW APARTMENT DIRECT AIR 0.271848
F7 NW APARTMENT DIRECT AIR 0.252058
F7 SE APARTMENT DIRECT AIR 0.240472
F7 NE APARTMENT DIRECT AIR 0.196022
F7 N1 APARTMENT DIRECT AIR 0.141657
F7 N2 APARTMENT DIRECT AIR 0.140350
F7 S1 APARTMENT DIRECT AIR 0.175882
F7 S2 APARTMENT DIRECT AIR 0.176800
F8 SW APARTMENT DIRECT AIR 0.271843
F8 NW APARTMENT DIRECT AIR 0.252227
F8 SE APARTMENT DIRECT AIR 0.240647
F8 NE APARTMENT DIRECT AIR 0.196150
F8 N1 APARTMENT DIRECT AIR 0.142119
F8 N2 APARTMENT DIRECT AIR 0.140821
F8 S1 APARTMENT DIRECT AIR 0.176030
F8 S2 APARTMENT DIRECT AIR 0.176949
F9 SW APARTMENT DIRECT AIR 0.280215
F9 NW APARTMENT DIRECT AIR 0.260390
F9 SE APARTMENT DIRECT AIR 0.246581
F9 NE APARTMENT DIRECT AIR 0.199229
F9 N1 APARTMENT DIRECT AIR 0.149336
F9 N2 APARTMENT DIRECT AIR 0.148020
F9 S1 APARTMENT DIRECT AIR 0.181084
F9 S2 APARTMENT DIRECT AIR 0.182000
T SW APARTMENT DIRECT AIR 0.334258
T NW APARTMENT DIRECT AIR 0.306719
T SE APARTMENT DIRECT AIR 0.302281
T NE APARTMENT DIRECT AIR 0.242108
T N1 APARTMENT DIRECT AIR 0.176197
T N2 APARTMENT DIRECT AIR 0.176088
T S1 APARTMENT DIRECT AIR 0.246278
T S2 APARTMENT DIRECT AIR 0.247225


Branch

Maximum Flow Rate [m3/s]
AIRLOOP G SW MAIN BRANCH 0.206405
AIRLOOP G NW MAIN BRANCH 0.190865
AIRLOOP OFFICE MAIN BRANCH 0.282588
AIRLOOP G NE MAIN BRANCH 0.140673
AIRLOOP G N1 MAIN BRANCH 0.097092
AIRLOOP G N2 MAIN BRANCH 0.095464
AIRLOOP G S1 MAIN BRANCH 0.127092
AIRLOOP G S2 MAIN BRANCH 0.132242
AIRLOOP F2 SW MAIN BRANCH 0.272745
AIRLOOP F2 NW MAIN BRANCH 0.250437
AIRLOOP F2 SE MAIN BRANCH 0.256530
AIRLOOP F2 NE MAIN BRANCH 0.193028
AIRLOOP F2 N1 MAIN BRANCH 0.136803
AIRLOOP F2 N2 MAIN BRANCH 0.135444
AIRLOOP F2 S1 MAIN BRANCH 0.172859
AIRLOOP F2 S2 MAIN BRANCH 0.174938
AIRLOOP F3 SW MAIN BRANCH 0.273783
AIRLOOP F3 NW MAIN BRANCH 0.252888
AIRLOOP F3 SE MAIN BRANCH 0.242640
AIRLOOP F3 NE MAIN BRANCH 0.196685
AIRLOOP F3 N1 MAIN BRANCH 0.140834
AIRLOOP F3 N2 MAIN BRANCH 0.139492
AIRLOOP F3 S1 MAIN BRANCH 0.176368
AIRLOOP F3 S2 MAIN BRANCH 0.177452
AIRLOOP F4 SW MAIN BRANCH 0.274269
AIRLOOP F4 NW MAIN BRANCH 0.253790
AIRLOOP F4 SE MAIN BRANCH 0.242054
AIRLOOP F4 NE MAIN BRANCH 0.197616
AIRLOOP F4 N1 MAIN BRANCH 0.142293
AIRLOOP F4 N2 MAIN BRANCH 0.140958
AIRLOOP F4 S1 MAIN BRANCH 0.177414
AIRLOOP F4 S2 MAIN BRANCH 0.178356
AIRLOOP M SW MAIN BRANCH 0.276911
AIRLOOP M NW MAIN BRANCH 0.256791
AIRLOOP M SE MAIN BRANCH 0.244887
AIRLOOP M NE MAIN BRANCH 0.200584
AIRLOOP M N1 MAIN BRANCH 0.145553
AIRLOOP M N2 MAIN BRANCH 0.144224
AIRLOOP M S1 MAIN BRANCH 0.180356
AIRLOOP M S2 MAIN BRANCH 0.181277
AIRLOOP F6 SW MAIN BRANCH 0.273192
AIRLOOP F6 NW MAIN BRANCH 0.253204
AIRLOOP F6 SE MAIN BRANCH 0.241516
AIRLOOP F6 NE MAIN BRANCH 0.197114
AIRLOOP F6 N1 MAIN BRANCH 0.142474
AIRLOOP F6 N2 MAIN BRANCH 0.141158
AIRLOOP F6 S1 MAIN BRANCH 0.176976
AIRLOOP F6 S2 MAIN BRANCH 0.177894
AIRLOOP F7 SW MAIN BRANCH 0.271848
AIRLOOP F7 NW MAIN BRANCH 0.252058
AIRLOOP F7 SE MAIN BRANCH 0.240472
AIRLOOP F7 NE MAIN BRANCH 0.196022
AIRLOOP F7 N1 MAIN BRANCH 0.141657
AIRLOOP F7 N2 MAIN BRANCH 0.140350
AIRLOOP F7 S1 MAIN BRANCH 0.175882
AIRLOOP F7 S2 MAIN BRANCH 0.176800
AIRLOOP F8 SW MAIN BRANCH 0.271843
AIRLOOP F8 NW MAIN BRANCH 0.252227
AIRLOOP F8 SE MAIN BRANCH 0.240647
AIRLOOP F8 NE MAIN BRANCH 0.196150
AIRLOOP F8 N1 MAIN BRANCH 0.142119
AIRLOOP F8 N2 MAIN BRANCH 0.140821
AIRLOOP F8 S1 MAIN BRANCH 0.176030
AIRLOOP F8 S2 MAIN BRANCH 0.176949
AIRLOOP F9 SW MAIN BRANCH 0.280215
AIRLOOP F9 NW MAIN BRANCH 0.260390
AIRLOOP F9 SE MAIN BRANCH 0.246581
AIRLOOP F9 NE MAIN BRANCH 0.199229
AIRLOOP F9 N1 MAIN BRANCH 0.149336
AIRLOOP F9 N2 MAIN BRANCH 0.148020
AIRLOOP F9 S1 MAIN BRANCH 0.181084
AIRLOOP F9 S2 MAIN BRANCH 0.182000
AIRLOOP T SW MAIN BRANCH 0.334258
AIRLOOP T NW MAIN BRANCH 0.306719
AIRLOOP T SE MAIN BRANCH 0.302281
AIRLOOP T NE MAIN BRANCH 0.242108
AIRLOOP T N1 MAIN BRANCH 0.176197
AIRLOOP T N2 MAIN BRANCH 0.176088
AIRLOOP T S1 MAIN BRANCH 0.246278
AIRLOOP T S2 MAIN BRANCH 0.247225


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
AIRLOOP G SW 0.206405
AIRLOOP G NW 0.190865
AIRLOOP OFFICE 0.282588
AIRLOOP G NE 0.140673
AIRLOOP G N1 0.097092
AIRLOOP G N2 0.095464
AIRLOOP G S1 0.127092
AIRLOOP G S2 0.132242
AIRLOOP F2 SW 0.272745
AIRLOOP F2 NW 0.250437
AIRLOOP F2 SE 0.256530
AIRLOOP F2 NE 0.193028
AIRLOOP F2 N1 0.136803
AIRLOOP F2 N2 0.135444
AIRLOOP F2 S1 0.172859
AIRLOOP F2 S2 0.174938
AIRLOOP F3 SW 0.273783
AIRLOOP F3 NW 0.252888
AIRLOOP F3 SE 0.242640
AIRLOOP F3 NE 0.196685
AIRLOOP F3 N1 0.140834
AIRLOOP F3 N2 0.139492
AIRLOOP F3 S1 0.176368
AIRLOOP F3 S2 0.177452
AIRLOOP F4 SW 0.274269
AIRLOOP F4 NW 0.253790
AIRLOOP F4 SE 0.242054
AIRLOOP F4 NE 0.197616
AIRLOOP F4 N1 0.142293
AIRLOOP F4 N2 0.140958
AIRLOOP F4 S1 0.177414
AIRLOOP F4 S2 0.178356
AIRLOOP M SW 0.276911
AIRLOOP M NW 0.256791
AIRLOOP M SE 0.244887
AIRLOOP M NE 0.200584
AIRLOOP M N1 0.145553
AIRLOOP M N2 0.144224
AIRLOOP M S1 0.180356
AIRLOOP M S2 0.181277
AIRLOOP F6 SW 0.273192
AIRLOOP F6 NW 0.253204
AIRLOOP F6 SE 0.241516
AIRLOOP F6 NE 0.197114
AIRLOOP F6 N1 0.142474
AIRLOOP F6 N2 0.141158
AIRLOOP F6 S1 0.176976
AIRLOOP F6 S2 0.177894
AIRLOOP F7 SW 0.271848
AIRLOOP F7 NW 0.252058
AIRLOOP F7 SE 0.240472
AIRLOOP F7 NE 0.196022
AIRLOOP F7 N1 0.141657
AIRLOOP F7 N2 0.140350
AIRLOOP F7 S1 0.175882
AIRLOOP F7 S2 0.176800
AIRLOOP F8 SW 0.271843
AIRLOOP F8 NW 0.252227
AIRLOOP F8 SE 0.240647
AIRLOOP F8 NE 0.196150
AIRLOOP F8 N1 0.142119
AIRLOOP F8 N2 0.140821
AIRLOOP F8 S1 0.176030
AIRLOOP F8 S2 0.176949
AIRLOOP F9 SW 0.280215
AIRLOOP F9 NW 0.260390
AIRLOOP F9 SE 0.246581
AIRLOOP F9 NE 0.199229
AIRLOOP F9 N1 0.149336
AIRLOOP F9 N2 0.148020
AIRLOOP F9 S1 0.181084
AIRLOOP F9 S2 0.182000
AIRLOOP T SW 0.334258
AIRLOOP T NW 0.306719
AIRLOOP T SE 0.302281
AIRLOOP T NE 0.242108
AIRLOOP T N1 0.176197
AIRLOOP T N2 0.176088
AIRLOOP T S1 0.246278
AIRLOOP T S2 0.247225


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
AIRLOOP G SW OA CONTROLLER 0.206405 0.025952
AIRLOOP G NW OA CONTROLLER 0.190865 0.025952
AIRLOOP OFFICE OA CONTROLLER 0.282588 0.038103
AIRLOOP G NE OA CONTROLLER 0.140673 0.025952
AIRLOOP G N1 OA CONTROLLER 0.097092 0.025952
AIRLOOP G N2 OA CONTROLLER 0.095464 0.025952
AIRLOOP G S1 OA CONTROLLER 0.127092 0.025952
AIRLOOP G S2 OA CONTROLLER 0.132242 0.025952
AIRLOOP F2 SW OA CONTROLLER 0.272745 0.025952
AIRLOOP F2 NW OA CONTROLLER 0.250437 0.025952
AIRLOOP F2 SE OA CONTROLLER 0.256530 0.025952
AIRLOOP F2 NE OA CONTROLLER 0.193028 0.025952
AIRLOOP F2 N1 OA CONTROLLER 0.136803 0.025952
AIRLOOP F2 N2 OA CONTROLLER 0.135444 0.025952
AIRLOOP F2 S1 OA CONTROLLER 0.172859 0.025952
AIRLOOP F2 S2 OA CONTROLLER 0.174938 0.025952
AIRLOOP F3 SW OA CONTROLLER 0.273783 0.025952
AIRLOOP F3 NW OA CONTROLLER 0.252888 0.025952
AIRLOOP F3 SE OA CONTROLLER 0.242640 0.025952
AIRLOOP F3 NE OA CONTROLLER 0.196685 0.025952
AIRLOOP F3 N1 OA CONTROLLER 0.140834 0.025952
AIRLOOP F3 N2 OA CONTROLLER 0.139492 0.025952
AIRLOOP F3 S1 OA CONTROLLER 0.176368 0.025952
AIRLOOP F3 S2 OA CONTROLLER 0.177452 0.025952
AIRLOOP F4 SW OA CONTROLLER 0.274269 0.025952
AIRLOOP F4 NW OA CONTROLLER 0.253790 0.025952
AIRLOOP F4 SE OA CONTROLLER 0.242054 0.025952
AIRLOOP F4 NE OA CONTROLLER 0.197616 0.025952
AIRLOOP F4 N1 OA CONTROLLER 0.142293 0.025952
AIRLOOP F4 N2 OA CONTROLLER 0.140958 0.025952
AIRLOOP F4 S1 OA CONTROLLER 0.177414 0.025952
AIRLOOP F4 S2 OA CONTROLLER 0.178356 0.025952
AIRLOOP M SW OA CONTROLLER 0.276911 0.025952
AIRLOOP M NW OA CONTROLLER 0.256791 0.025952
AIRLOOP M SE OA CONTROLLER 0.244887 0.025952
AIRLOOP M NE OA CONTROLLER 0.200584 0.025952
AIRLOOP M N1 OA CONTROLLER 0.145553 0.025952
AIRLOOP M N2 OA CONTROLLER 0.144224 0.025952
AIRLOOP M S1 OA CONTROLLER 0.180356 0.025952
AIRLOOP M S2 OA CONTROLLER 0.181277 0.025952
AIRLOOP F6 SW OA CONTROLLER 0.273192 0.025952
AIRLOOP F6 NW OA CONTROLLER 0.253204 0.025952
AIRLOOP F6 SE OA CONTROLLER 0.241516 0.025952
AIRLOOP F6 NE OA CONTROLLER 0.197114 0.025952
AIRLOOP F6 N1 OA CONTROLLER 0.142474 0.025952
AIRLOOP F6 N2 OA CONTROLLER 0.141158 0.025952
AIRLOOP F6 S1 OA CONTROLLER 0.176976 0.025952
AIRLOOP F6 S2 OA CONTROLLER 0.177894 0.025952
AIRLOOP F7 SW OA CONTROLLER 0.271848 0.025952
AIRLOOP F7 NW OA CONTROLLER 0.252058 0.025952
AIRLOOP F7 SE OA CONTROLLER 0.240472 0.025952
AIRLOOP F7 NE OA CONTROLLER 0.196022 0.025952
AIRLOOP F7 N1 OA CONTROLLER 0.141657 0.025952
AIRLOOP F7 N2 OA CONTROLLER 0.140350 0.025952
AIRLOOP F7 S1 OA CONTROLLER 0.175882 0.025952
AIRLOOP F7 S2 OA CONTROLLER 0.176800 0.025952
AIRLOOP F8 SW OA CONTROLLER 0.271843 0.025952
AIRLOOP F8 NW OA CONTROLLER 0.252227 0.025952
AIRLOOP F8 SE OA CONTROLLER 0.240647 0.025952
AIRLOOP F8 NE OA CONTROLLER 0.196150 0.025952
AIRLOOP F8 N1 OA CONTROLLER 0.142119 0.025952
AIRLOOP F8 N2 OA CONTROLLER 0.140821 0.025952
AIRLOOP F8 S1 OA CONTROLLER 0.176030 0.025952
AIRLOOP F8 S2 OA CONTROLLER 0.176949 0.025952
AIRLOOP F9 SW OA CONTROLLER 0.280215 0.025952
AIRLOOP F9 NW OA CONTROLLER 0.260390 0.025952
AIRLOOP F9 SE OA CONTROLLER 0.246581 0.025952
AIRLOOP F9 NE OA CONTROLLER 0.199229 0.025952
AIRLOOP F9 N1 OA CONTROLLER 0.149336 0.025952
AIRLOOP F9 N2 OA CONTROLLER 0.148020 0.025952
AIRLOOP F9 S1 OA CONTROLLER 0.181084 0.025952
AIRLOOP F9 S2 OA CONTROLLER 0.182000 0.025952
AIRLOOP T SW OA CONTROLLER 0.334258 0.025952
AIRLOOP T NW OA CONTROLLER 0.306719 0.025952
AIRLOOP T SE OA CONTROLLER 0.302281 0.025952
AIRLOOP T NE OA CONTROLLER 0.242108 0.025952
AIRLOOP T N1 OA CONTROLLER 0.176197 0.025952
AIRLOOP T N2 OA CONTROLLER 0.176088 0.025952
AIRLOOP T S1 OA CONTROLLER 0.246278 0.025952
AIRLOOP T S2 OA CONTROLLER 0.247225 0.025952


COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity [W] Rated Sensible Cooling Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP COOLING MODE AIRLOOP G SW 0.206405 3528.92 2377.71 0.000077
HEAT PUMP COOLING MODE AIRLOOP G NW 0.190865 3306.49 2210.54 0.000072
HEAT PUMP COOLING MODE AIRLOOP OFFICE 0.282588 4854.57 3276.14 0.000106
HEAT PUMP COOLING MODE AIRLOOP G NE 0.140673 2565.01 1668.04 0.000056
HEAT PUMP COOLING MODE AIRLOOP G N1 0.097092 1903.95 1196.19 0.000042
HEAT PUMP COOLING MODE AIRLOOP G N2 0.095464 1879.98 1178.96 0.000041
HEAT PUMP COOLING MODE AIRLOOP G S1 0.127092 2400.02 1547.85 0.000052
HEAT PUMP COOLING MODE AIRLOOP G S2 0.132242 2472.34 1601.88 0.000054
HEAT PUMP COOLING MODE AIRLOOP F2 SW 0.272745 4518.49 3092.88 0.000099
HEAT PUMP COOLING MODE AIRLOOP F2 NW 0.250437 4201.37 2854.19 0.000092
HEAT PUMP COOLING MODE AIRLOOP F2 SE 0.256530 4323.42 2939.96 0.000094
HEAT PUMP COOLING MODE AIRLOOP F2 NE 0.193028 3354.89 2233.43 0.000073
HEAT PUMP COOLING MODE AIRLOOP F2 N1 0.136803 2505.25 1623.71 0.000055
HEAT PUMP COOLING MODE AIRLOOP F2 N2 0.135444 2485.64 1609.34 0.000054
HEAT PUMP COOLING MODE AIRLOOP F2 S1 0.172859 3077.96 2039.27 0.000067
HEAT PUMP COOLING MODE AIRLOOP F2 S2 0.174938 3107.05 2061.10 0.000068
HEAT PUMP COOLING MODE AIRLOOP F3 SW 0.273783 4569.22 3114.12 0.000100
HEAT PUMP COOLING MODE AIRLOOP F3 NW 0.252888 4271.16 2890.19 0.000093
HEAT PUMP COOLING MODE AIRLOOP F3 SE 0.242640 4163.86 2803.94 0.000091
HEAT PUMP COOLING MODE AIRLOOP F3 NE 0.196685 3439.42 2281.73 0.000075
HEAT PUMP COOLING MODE AIRLOOP F3 N1 0.140834 2581.65 1672.02 0.000056
HEAT PUMP COOLING MODE AIRLOOP F3 N2 0.139492 2562.25 1657.83 0.000056
HEAT PUMP COOLING MODE AIRLOOP F3 S1 0.176368 3147.65 2082.24 0.000069
HEAT PUMP COOLING MODE AIRLOOP F3 S2 0.177452 3162.79 2093.61 0.000069
HEAT PUMP COOLING MODE AIRLOOP F4 SW 0.274269 4602.93 3126.94 0.000101
HEAT PUMP COOLING MODE AIRLOOP F4 NW 0.253790 4310.18 2907.33 0.000094
HEAT PUMP COOLING MODE AIRLOOP F4 SE 0.242054 4181.53 2805.32 0.000091
HEAT PUMP COOLING MODE AIRLOOP F4 NE 0.197616 3477.13 2298.90 0.000076
HEAT PUMP COOLING MODE AIRLOOP F4 N1 0.142293 2616.57 1691.79 0.000057
HEAT PUMP COOLING MODE AIRLOOP F4 N2 0.140958 2597.23 1677.67 0.000057
HEAT PUMP COOLING MODE AIRLOOP F4 S1 0.177414 3177.63 2097.80 0.000069
HEAT PUMP COOLING MODE AIRLOOP F4 S2 0.178356 3190.80 2107.68 0.000070
HEAT PUMP COOLING MODE AIRLOOP M SW 0.276911 4661.91 3161.05 0.000102
HEAT PUMP COOLING MODE AIRLOOP M NW 0.256791 4373.79 2945.15 0.000096
HEAT PUMP COOLING MODE AIRLOOP M SE 0.244887 4242.51 2841.33 0.000093
HEAT PUMP COOLING MODE AIRLOOP M NE 0.200584 3546.55 2340.28 0.000077
HEAT PUMP COOLING MODE AIRLOOP M N1 0.145553 2674.76 1729.73 0.000058
HEAT PUMP COOLING MODE AIRLOOP M N2 0.144224 2655.49 1715.67 0.000058
HEAT PUMP COOLING MODE AIRLOOP M S1 0.180356 3231.57 2132.49 0.000071
HEAT PUMP COOLING MODE AIRLOOP M S2 0.181277 3244.46 2142.16 0.000071
HEAT PUMP COOLING MODE AIRLOOP F6 SW 0.273192 4628.04 3127.23 0.000101
HEAT PUMP COOLING MODE AIRLOOP F6 NW 0.253204 4341.26 2912.67 0.000095
HEAT PUMP COOLING MODE AIRLOOP F6 SE 0.241516 4212.63 2811.02 0.000092
HEAT PUMP COOLING MODE AIRLOOP F6 NE 0.197114 3513.82 2308.77 0.000077
HEAT PUMP COOLING MODE AIRLOOP F6 N1 0.142474 2640.08 1700.31 0.000058
HEAT PUMP COOLING MODE AIRLOOP F6 N2 0.141158 2620.90 1686.36 0.000057
HEAT PUMP COOLING MODE AIRLOOP F6 S1 0.176976 3194.31 2100.05 0.000070
HEAT PUMP COOLING MODE AIRLOOP F6 S2 0.177894 3207.19 2109.69 0.000070
HEAT PUMP COOLING MODE AIRLOOP F7 SW 0.271848 4625.23 3117.77 0.000101
HEAT PUMP COOLING MODE AIRLOOP F7 NW 0.252058 4340.80 2905.22 0.000095
HEAT PUMP COOLING MODE AIRLOOP F7 SE 0.240472 4213.33 2804.58 0.000092
HEAT PUMP COOLING MODE AIRLOOP F7 NE 0.196022 3512.70 2301.67 0.000077
HEAT PUMP COOLING MODE AIRLOOP F7 N1 0.141657 2636.62 1694.34 0.000058
HEAT PUMP COOLING MODE AIRLOOP F7 N2 0.140350 2617.51 1680.47 0.000057
HEAT PUMP COOLING MODE AIRLOOP F7 S1 0.175882 3188.01 2091.31 0.000070
HEAT PUMP COOLING MODE AIRLOOP F7 S2 0.176800 3200.88 2100.94 0.000070
HEAT PUMP COOLING MODE AIRLOOP F8 SW 0.271843 4639.57 3121.92 0.000101
HEAT PUMP COOLING MODE AIRLOOP F8 NW 0.252227 4357.24 2911.15 0.000095
HEAT PUMP COOLING MODE AIRLOOP F8 SE 0.240647 4229.62 2810.53 0.000092
HEAT PUMP COOLING MODE AIRLOOP F8 NE 0.196150 3527.42 2306.98 0.000077
HEAT PUMP COOLING MODE AIRLOOP F8 N1 0.142119 2650.74 1701.59 0.000058
HEAT PUMP COOLING MODE AIRLOOP F8 N2 0.140821 2631.74 1687.82 0.000057
HEAT PUMP COOLING MODE AIRLOOP F8 S1 0.176030 3198.30 2095.35 0.000070
HEAT PUMP COOLING MODE AIRLOOP F8 S2 0.176949 3211.20 2104.99 0.000070
HEAT PUMP COOLING MODE AIRLOOP F9 SW 0.280215 4771.21 3214.06 0.000104
HEAT PUMP COOLING MODE AIRLOOP F9 NW 0.260390 4485.99 3001.09 0.000098
HEAT PUMP COOLING MODE AIRLOOP F9 SE 0.246581 4329.35 2878.35 0.000095
HEAT PUMP COOLING MODE AIRLOOP F9 NE 0.199229 3583.63 2343.21 0.000078
HEAT PUMP COOLING MODE AIRLOOP F9 N1 0.149336 2762.19 1780.06 0.000060
HEAT PUMP COOLING MODE AIRLOOP F9 N2 0.148020 2742.96 1766.09 0.000060
HEAT PUMP COOLING MODE AIRLOOP F9 S1 0.181084 3279.96 2152.19 0.000072
HEAT PUMP COOLING MODE AIRLOOP F9 S2 0.182000 3292.82 2161.81 0.000072
HEAT PUMP COOLING MODE AIRLOOP T SW 0.334258 5570.21 3802.02 0.000122
HEAT PUMP COOLING MODE AIRLOOP T NW 0.306719 5157.42 3496.95 0.000113
HEAT PUMP COOLING MODE AIRLOOP T SE 0.302281 5126.16 3467.80 0.000112
HEAT PUMP COOLING MODE AIRLOOP T NE 0.242108 4216.68 2803.92 0.000092
HEAT PUMP COOLING MODE AIRLOOP T N1 0.176197 3212.28 2100.53 0.000070
HEAT PUMP COOLING MODE AIRLOOP T N2 0.176088 3214.81 2101.27 0.000070
HEAT PUMP COOLING MODE AIRLOOP T S1 0.246278 4204.72 2839.89 0.000092
HEAT PUMP COOLING MODE AIRLOOP T S2 0.247225 4217.84 2849.80 0.000092


AirLoopHVAC:UnitaryHeatPump:WaterToAir

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Supplemental Heating Coil Nominal Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
AIRLOOP G SW DXAC HEAT PUMP 0.206405 0.206405 0.206405 0.206405 3528.92 3528.92 3875.68 1.00
AIRLOOP G NW DXAC HEAT PUMP 0.190865 0.190865 0.190865 0.190865 3306.49 3306.49 3881.41 1.00
AIRLOOP OFFICE DXAC HEAT PUMP 0.282588 0.282588 0.282588 0.282588 4854.57 4854.57 4864.18 1.00
AIRLOOP G NE DXAC HEAT PUMP 0.140673 0.140673 0.140673 0.140673 2565.01 2565.01 3882.12 1.00
AIRLOOP G N1 DXAC HEAT PUMP 0.097092 0.097092 0.097092 0.097092 1903.95 1903.95 2939.41 1.00
AIRLOOP G N2 DXAC HEAT PUMP 0.095464 0.095464 0.095464 0.095464 1879.98 1879.98 2939.41 1.00
AIRLOOP G S1 DXAC HEAT PUMP 0.127092 0.127092 0.127092 0.127092 2400.02 2400.02 2930.57 1.00
AIRLOOP G S2 DXAC HEAT PUMP 0.132242 0.132242 0.132242 0.132242 2472.34 2472.34 2939.07 1.00
AIRLOOP F2 SW DXAC HEAT PUMP 0.272745 0.272745 0.272745 0.272745 4518.49 4518.49 3896.08 1.00
AIRLOOP F2 NW DXAC HEAT PUMP 0.250437 0.250437 0.250437 0.250437 4201.37 4201.37 3895.59 1.00
AIRLOOP F2 SE DXAC HEAT PUMP 0.256530 0.256530 0.256530 0.256530 4323.42 4323.42 3917.02 1.00
AIRLOOP F2 NE DXAC HEAT PUMP 0.193028 0.193028 0.193028 0.193028 3354.89 3354.89 3891.76 1.00
AIRLOOP F2 N1 DXAC HEAT PUMP 0.136803 0.136803 0.136803 0.136803 2505.25 2505.25 2724.90 1.00
AIRLOOP F2 N2 DXAC HEAT PUMP 0.135444 0.135444 0.135444 0.135444 2485.64 2485.64 2724.81 1.00
AIRLOOP F2 S1 DXAC HEAT PUMP 0.172859 0.172859 0.172859 0.172859 3077.96 3077.96 2728.28 1.00
AIRLOOP F2 S2 DXAC HEAT PUMP 0.174938 0.174938 0.174938 0.174938 3107.05 3107.05 2729.76 1.00
AIRLOOP F3 SW DXAC HEAT PUMP 0.273783 0.273783 0.273783 0.273783 4569.22 4569.22 3958.78 1.00
AIRLOOP F3 NW DXAC HEAT PUMP 0.252888 0.252888 0.252888 0.252888 4271.16 4271.16 3959.97 1.00
AIRLOOP F3 SE DXAC HEAT PUMP 0.242640 0.242640 0.242640 0.242640 4163.86 4163.86 3954.60 1.00
AIRLOOP F3 NE DXAC HEAT PUMP 0.196685 0.196685 0.196685 0.196685 3439.42 3439.42 3953.19 1.00
AIRLOOP F3 N1 DXAC HEAT PUMP 0.140834 0.140834 0.140834 0.140834 2581.65 2581.65 2724.73 1.00
AIRLOOP F3 N2 DXAC HEAT PUMP 0.139492 0.139492 0.139492 0.139492 2562.25 2562.25 2724.58 1.00
AIRLOOP F3 S1 DXAC HEAT PUMP 0.176368 0.176368 0.176368 0.176368 3147.65 3147.65 2724.43 1.00
AIRLOOP F3 S2 DXAC HEAT PUMP 0.177452 0.177452 0.177452 0.177452 3162.79 3162.79 2724.51 1.00
AIRLOOP F4 SW DXAC HEAT PUMP 0.274269 0.274269 0.274269 0.274269 4602.93 4602.93 4061.22 1.00
AIRLOOP F4 NW DXAC HEAT PUMP 0.253790 0.253790 0.253790 0.253790 4310.18 4310.18 4063.03 1.00
AIRLOOP F4 SE DXAC HEAT PUMP 0.242054 0.242054 0.242054 0.242054 4181.53 4181.53 4052.63 1.00
AIRLOOP F4 NE DXAC HEAT PUMP 0.197616 0.197616 0.197616 0.197616 3477.13 3477.13 4054.19 1.00
AIRLOOP F4 N1 DXAC HEAT PUMP 0.142293 0.142293 0.142293 0.142293 2616.57 2616.57 2776.51 1.00
AIRLOOP F4 N2 DXAC HEAT PUMP 0.140958 0.140958 0.140958 0.140958 2597.23 2597.23 2776.31 1.00
AIRLOOP F4 S1 DXAC HEAT PUMP 0.177414 0.177414 0.177414 0.177414 3177.63 3177.63 2775.29 1.00
AIRLOOP F4 S2 DXAC HEAT PUMP 0.178356 0.178356 0.178356 0.178356 3190.80 3190.80 2775.12 1.00
AIRLOOP M SW DXAC HEAT PUMP 0.276911 0.276911 0.276911 0.276911 4661.91 4661.91 4130.63 1.00
AIRLOOP M NW DXAC HEAT PUMP 0.256791 0.256791 0.256791 0.256791 4373.79 4373.79 4131.45 1.00
AIRLOOP M SE DXAC HEAT PUMP 0.244887 0.244887 0.244887 0.244887 4242.51 4242.51 4120.25 1.00
AIRLOOP M NE DXAC HEAT PUMP 0.200584 0.200584 0.200584 0.200584 3546.55 3546.55 4121.04 1.00
AIRLOOP M N1 DXAC HEAT PUMP 0.145553 0.145553 0.145553 0.145553 2674.76 2674.76 2804.23 1.00
AIRLOOP M N2 DXAC HEAT PUMP 0.144224 0.144224 0.144224 0.144224 2655.49 2655.49 2803.98 1.00
AIRLOOP M S1 DXAC HEAT PUMP 0.180356 0.180356 0.180356 0.180356 3231.57 3231.57 2803.93 1.00
AIRLOOP M S2 DXAC HEAT PUMP 0.181277 0.181277 0.181277 0.181277 3244.46 3244.46 2803.69 1.00
AIRLOOP F6 SW DXAC HEAT PUMP 0.273192 0.273192 0.273192 0.273192 4628.04 4628.04 4259.15 1.00
AIRLOOP F6 NW DXAC HEAT PUMP 0.253204 0.253204 0.253204 0.253204 4341.26 4341.26 4260.97 1.00
AIRLOOP F6 SE DXAC HEAT PUMP 0.241516 0.241516 0.241516 0.241516 4212.63 4212.63 4247.48 1.00
AIRLOOP F6 NE DXAC HEAT PUMP 0.197114 0.197114 0.197114 0.197114 3513.82 3513.82 4249.30 1.00
AIRLOOP F6 N1 DXAC HEAT PUMP 0.142474 0.142474 0.142474 0.142474 2640.08 2640.08 2897.38 1.00
AIRLOOP F6 N2 DXAC HEAT PUMP 0.141158 0.141158 0.141158 0.141158 2620.90 2620.90 2897.10 1.00
AIRLOOP F6 S1 DXAC HEAT PUMP 0.176976 0.176976 0.176976 0.176976 3194.31 3194.31 2896.07 1.00
AIRLOOP F6 S2 DXAC HEAT PUMP 0.177894 0.177894 0.177894 0.177894 3207.19 3207.19 2895.79 1.00
AIRLOOP F7 SW DXAC HEAT PUMP 0.271848 0.271848 0.271848 0.271848 4625.23 4625.23 4353.54 1.00
AIRLOOP F7 NW DXAC HEAT PUMP 0.252058 0.252058 0.252058 0.252058 4340.80 4340.80 4355.13 1.00
AIRLOOP F7 SE DXAC HEAT PUMP 0.240472 0.240472 0.240472 0.240472 4213.33 4213.33 4340.83 1.00
AIRLOOP F7 NE DXAC HEAT PUMP 0.196022 0.196022 0.196022 0.196022 3512.70 3512.70 4342.42 1.00
AIRLOOP F7 N1 DXAC HEAT PUMP 0.141657 0.141657 0.141657 0.141657 2636.62 2636.62 2960.61 1.00
AIRLOOP F7 N2 DXAC HEAT PUMP 0.140350 0.140350 0.140350 0.140350 2617.51 2617.51 2960.31 1.00
AIRLOOP F7 S1 DXAC HEAT PUMP 0.175882 0.175882 0.175882 0.175882 3188.01 3188.01 2959.55 1.00
AIRLOOP F7 S2 DXAC HEAT PUMP 0.176800 0.176800 0.176800 0.176800 3200.88 3200.88 2959.25 1.00
AIRLOOP F8 SW DXAC HEAT PUMP 0.271843 0.271843 0.271843 0.271843 4639.57 4639.57 4449.52 1.00
AIRLOOP F8 NW DXAC HEAT PUMP 0.252227 0.252227 0.252227 0.252227 4357.24 4357.24 4450.55 1.00
AIRLOOP F8 SE DXAC HEAT PUMP 0.240647 0.240647 0.240647 0.240647 4229.62 4229.62 4435.91 1.00
AIRLOOP F8 NE DXAC HEAT PUMP 0.196150 0.196150 0.196150 0.196150 3527.42 3527.42 4436.96 1.00
AIRLOOP F8 N1 DXAC HEAT PUMP 0.142119 0.142119 0.142119 0.142119 2650.74 2650.74 3028.55 1.00
AIRLOOP F8 N2 DXAC HEAT PUMP 0.140821 0.140821 0.140821 0.140821 2631.74 2631.74 3028.23 1.00
AIRLOOP F8 S1 DXAC HEAT PUMP 0.176030 0.176030 0.176030 0.176030 3198.30 3198.30 3028.04 1.00
AIRLOOP F8 S2 DXAC HEAT PUMP 0.176949 0.176949 0.176949 0.176949 3211.20 3211.20 3027.72 1.00
AIRLOOP F9 SW DXAC HEAT PUMP 0.280215 0.280215 0.280215 0.280215 4771.21 4771.21 4687.48 1.00
AIRLOOP F9 NW DXAC HEAT PUMP 0.260390 0.260390 0.260390 0.260390 4485.99 4485.99 4684.96 1.00
AIRLOOP F9 SE DXAC HEAT PUMP 0.246581 0.246581 0.246581 0.246581 4329.35 4329.35 4672.98 1.00
AIRLOOP F9 NE DXAC HEAT PUMP 0.199229 0.199229 0.199229 0.199229 3583.63 3583.63 4670.47 1.00
AIRLOOP F9 N1 DXAC HEAT PUMP 0.149336 0.149336 0.149336 0.149336 2762.19 2762.19 3228.12 1.00
AIRLOOP F9 N2 DXAC HEAT PUMP 0.148020 0.148020 0.148020 0.148020 2742.96 2742.96 3227.78 1.00
AIRLOOP F9 S1 DXAC HEAT PUMP 0.181084 0.181084 0.181084 0.181084 3279.96 3279.96 3230.74 1.00
AIRLOOP F9 S2 DXAC HEAT PUMP 0.182000 0.182000 0.182000 0.182000 3292.82 3292.82 3230.40 1.00
AIRLOOP T SW DXAC HEAT PUMP 0.334258 0.334258 0.334258 0.334258 5570.21 5570.21 5454.99 1.00
AIRLOOP T NW DXAC HEAT PUMP 0.306719 0.306719 0.306719 0.306719 5157.42 5157.42 5460.29 1.00
AIRLOOP T SE DXAC HEAT PUMP 0.302281 0.302281 0.302281 0.302281 5126.16 5126.16 5440.98 1.00
AIRLOOP T NE DXAC HEAT PUMP 0.242108 0.242108 0.242108 0.242108 4216.68 4216.68 5446.29 1.00
AIRLOOP T N1 DXAC HEAT PUMP 0.176197 0.176197 0.176197 0.176197 3212.28 3212.28 4048.30 1.00
AIRLOOP T N2 DXAC HEAT PUMP 0.176088 0.176088 0.176088 0.176088 3214.81 3214.81 4047.95 1.00
AIRLOOP T S1 DXAC HEAT PUMP 0.246278 0.246278 0.246278 0.246278 4204.72 4204.72 4040.26 1.00
AIRLOOP T S2 DXAC HEAT PUMP 0.247225 0.247225 0.247225 0.247225 4217.84 4217.84 4039.91 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
AIRLOOP G SW SUPPLY FAN 0.206405
AIRLOOP G NW SUPPLY FAN 0.190865
AIRLOOP OFFICE SUPPLY FAN 0.282588
AIRLOOP G NE SUPPLY FAN 0.140673
AIRLOOP G N1 SUPPLY FAN 0.097092
AIRLOOP G N2 SUPPLY FAN 0.095464
AIRLOOP G S1 SUPPLY FAN 0.127092
AIRLOOP G S2 SUPPLY FAN 0.132242
AIRLOOP F2 SW SUPPLY FAN 0.272745
AIRLOOP F2 NW SUPPLY FAN 0.250437
AIRLOOP F2 SE SUPPLY FAN 0.256530
AIRLOOP F2 NE SUPPLY FAN 0.193028
AIRLOOP F2 N1 SUPPLY FAN 0.136803
AIRLOOP F2 N2 SUPPLY FAN 0.135444
AIRLOOP F2 S1 SUPPLY FAN 0.172859
AIRLOOP F2 S2 SUPPLY FAN 0.174938
AIRLOOP F3 SW SUPPLY FAN 0.273783
AIRLOOP F3 NW SUPPLY FAN 0.252888
AIRLOOP F3 SE SUPPLY FAN 0.242640
AIRLOOP F3 NE SUPPLY FAN 0.196685
AIRLOOP F3 N1 SUPPLY FAN 0.140834
AIRLOOP F3 N2 SUPPLY FAN 0.139492
AIRLOOP F3 S1 SUPPLY FAN 0.176368
AIRLOOP F3 S2 SUPPLY FAN 0.177452
AIRLOOP F4 SW SUPPLY FAN 0.274269
AIRLOOP F4 NW SUPPLY FAN 0.253790
AIRLOOP F4 SE SUPPLY FAN 0.242054
AIRLOOP F4 NE SUPPLY FAN 0.197616
AIRLOOP F4 N1 SUPPLY FAN 0.142293
AIRLOOP F4 N2 SUPPLY FAN 0.140958
AIRLOOP F4 S1 SUPPLY FAN 0.177414
AIRLOOP F4 S2 SUPPLY FAN 0.178356
AIRLOOP M SW SUPPLY FAN 0.276911
AIRLOOP M NW SUPPLY FAN 0.256791
AIRLOOP M SE SUPPLY FAN 0.244887
AIRLOOP M NE SUPPLY FAN 0.200584
AIRLOOP M N1 SUPPLY FAN 0.145553
AIRLOOP M N2 SUPPLY FAN 0.144224
AIRLOOP M S1 SUPPLY FAN 0.180356
AIRLOOP M S2 SUPPLY FAN 0.181277
AIRLOOP F6 SW SUPPLY FAN 0.273192
AIRLOOP F6 NW SUPPLY FAN 0.253204
AIRLOOP F6 SE SUPPLY FAN 0.241516
AIRLOOP F6 NE SUPPLY FAN 0.197114
AIRLOOP F6 N1 SUPPLY FAN 0.142474
AIRLOOP F6 N2 SUPPLY FAN 0.141158
AIRLOOP F6 S1 SUPPLY FAN 0.176976
AIRLOOP F6 S2 SUPPLY FAN 0.177894
AIRLOOP F7 SW SUPPLY FAN 0.271848
AIRLOOP F7 NW SUPPLY FAN 0.252058
AIRLOOP F7 SE SUPPLY FAN 0.240472
AIRLOOP F7 NE SUPPLY FAN 0.196022
AIRLOOP F7 N1 SUPPLY FAN 0.141657
AIRLOOP F7 N2 SUPPLY FAN 0.140350
AIRLOOP F7 S1 SUPPLY FAN 0.175882
AIRLOOP F7 S2 SUPPLY FAN 0.176800
AIRLOOP F8 SW SUPPLY FAN 0.271843
AIRLOOP F8 NW SUPPLY FAN 0.252227
AIRLOOP F8 SE SUPPLY FAN 0.240647
AIRLOOP F8 NE SUPPLY FAN 0.196150
AIRLOOP F8 N1 SUPPLY FAN 0.142119
AIRLOOP F8 N2 SUPPLY FAN 0.140821
AIRLOOP F8 S1 SUPPLY FAN 0.176030
AIRLOOP F8 S2 SUPPLY FAN 0.176949
AIRLOOP F9 SW SUPPLY FAN 0.280215
AIRLOOP F9 NW SUPPLY FAN 0.260390
AIRLOOP F9 SE SUPPLY FAN 0.246581
AIRLOOP F9 NE SUPPLY FAN 0.199229
AIRLOOP F9 N1 SUPPLY FAN 0.149336
AIRLOOP F9 N2 SUPPLY FAN 0.148020
AIRLOOP F9 S1 SUPPLY FAN 0.181084
AIRLOOP F9 S2 SUPPLY FAN 0.182000
AIRLOOP T SW SUPPLY FAN 0.334258
AIRLOOP T NW SUPPLY FAN 0.306719
AIRLOOP T SE SUPPLY FAN 0.302281
AIRLOOP T NE SUPPLY FAN 0.242108
AIRLOOP T N1 SUPPLY FAN 0.176197
AIRLOOP T N2 SUPPLY FAN 0.176088
AIRLOOP T S1 SUPPLY FAN 0.246278
AIRLOOP T S2 SUPPLY FAN 0.247225


COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Heating Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP HEATING MODE AIRLOOP G SW 0.206405 3528.92 0.000077
HEAT PUMP HEATING MODE AIRLOOP G NW 0.190865 3306.49 0.000072
HEAT PUMP HEATING MODE AIRLOOP OFFICE 0.282588 4854.57 0.000106
HEAT PUMP HEATING MODE AIRLOOP G NE 0.140673 2565.01 0.000056
HEAT PUMP HEATING MODE AIRLOOP G N1 0.097092 1903.95 0.000042
HEAT PUMP HEATING MODE AIRLOOP G N2 0.095464 1879.98 0.000041
HEAT PUMP HEATING MODE AIRLOOP G S1 0.127092 2400.02 0.000052
HEAT PUMP HEATING MODE AIRLOOP G S2 0.132242 2472.34 0.000054
HEAT PUMP HEATING MODE AIRLOOP F2 SW 0.272745 4518.49 0.000099
HEAT PUMP HEATING MODE AIRLOOP F2 NW 0.250437 4201.37 0.000092
HEAT PUMP HEATING MODE AIRLOOP F2 SE 0.256530 4323.42 0.000094
HEAT PUMP HEATING MODE AIRLOOP F2 NE 0.193028 3354.89 0.000073
HEAT PUMP HEATING MODE AIRLOOP F2 N1 0.136803 2505.25 0.000055
HEAT PUMP HEATING MODE AIRLOOP F2 N2 0.135444 2485.64 0.000054
HEAT PUMP HEATING MODE AIRLOOP F2 S1 0.172859 3077.96 0.000067
HEAT PUMP HEATING MODE AIRLOOP F2 S2 0.174938 3107.05 0.000068
HEAT PUMP HEATING MODE AIRLOOP F3 SW 0.273783 4569.22 0.000100
HEAT PUMP HEATING MODE AIRLOOP F3 NW 0.252888 4271.16 0.000093
HEAT PUMP HEATING MODE AIRLOOP F3 SE 0.242640 4163.86 0.000091
HEAT PUMP HEATING MODE AIRLOOP F3 NE 0.196685 3439.42 0.000075
HEAT PUMP HEATING MODE AIRLOOP F3 N1 0.140834 2581.65 0.000056
HEAT PUMP HEATING MODE AIRLOOP F3 N2 0.139492 2562.25 0.000056
HEAT PUMP HEATING MODE AIRLOOP F3 S1 0.176368 3147.65 0.000069
HEAT PUMP HEATING MODE AIRLOOP F3 S2 0.177452 3162.79 0.000069
HEAT PUMP HEATING MODE AIRLOOP F4 SW 0.274269 4602.93 0.000101
HEAT PUMP HEATING MODE AIRLOOP F4 NW 0.253790 4310.18 0.000094
HEAT PUMP HEATING MODE AIRLOOP F4 SE 0.242054 4181.53 0.000091
HEAT PUMP HEATING MODE AIRLOOP F4 NE 0.197616 3477.13 0.000076
HEAT PUMP HEATING MODE AIRLOOP F4 N1 0.142293 2616.57 0.000057
HEAT PUMP HEATING MODE AIRLOOP F4 N2 0.140958 2597.23 0.000057
HEAT PUMP HEATING MODE AIRLOOP F4 S1 0.177414 3177.63 0.000069
HEAT PUMP HEATING MODE AIRLOOP F4 S2 0.178356 3190.80 0.000070
HEAT PUMP HEATING MODE AIRLOOP M SW 0.276911 4661.91 0.000102
HEAT PUMP HEATING MODE AIRLOOP M NW 0.256791 4373.79 0.000096
HEAT PUMP HEATING MODE AIRLOOP M SE 0.244887 4242.51 0.000093
HEAT PUMP HEATING MODE AIRLOOP M NE 0.200584 3546.55 0.000077
HEAT PUMP HEATING MODE AIRLOOP M N1 0.145553 2674.76 0.000058
HEAT PUMP HEATING MODE AIRLOOP M N2 0.144224 2655.49 0.000058
HEAT PUMP HEATING MODE AIRLOOP M S1 0.180356 3231.57 0.000071
HEAT PUMP HEATING MODE AIRLOOP M S2 0.181277 3244.46 0.000071
HEAT PUMP HEATING MODE AIRLOOP F6 SW 0.273192 4628.04 0.000101
HEAT PUMP HEATING MODE AIRLOOP F6 NW 0.253204 4341.26 0.000095
HEAT PUMP HEATING MODE AIRLOOP F6 SE 0.241516 4212.63 0.000092
HEAT PUMP HEATING MODE AIRLOOP F6 NE 0.197114 3513.82 0.000077
HEAT PUMP HEATING MODE AIRLOOP F6 N1 0.142474 2640.08 0.000058
HEAT PUMP HEATING MODE AIRLOOP F6 N2 0.141158 2620.90 0.000057
HEAT PUMP HEATING MODE AIRLOOP F6 S1 0.176976 3194.31 0.000070
HEAT PUMP HEATING MODE AIRLOOP F6 S2 0.177894 3207.19 0.000070
HEAT PUMP HEATING MODE AIRLOOP F7 SW 0.271848 4625.23 0.000101
HEAT PUMP HEATING MODE AIRLOOP F7 NW 0.252058 4340.80 0.000095
HEAT PUMP HEATING MODE AIRLOOP F7 SE 0.240472 4213.33 0.000092
HEAT PUMP HEATING MODE AIRLOOP F7 NE 0.196022 3512.70 0.000077
HEAT PUMP HEATING MODE AIRLOOP F7 N1 0.141657 2636.62 0.000058
HEAT PUMP HEATING MODE AIRLOOP F7 N2 0.140350 2617.51 0.000057
HEAT PUMP HEATING MODE AIRLOOP F7 S1 0.175882 3188.01 0.000070
HEAT PUMP HEATING MODE AIRLOOP F7 S2 0.176800 3200.88 0.000070
HEAT PUMP HEATING MODE AIRLOOP F8 SW 0.271843 4639.57 0.000101
HEAT PUMP HEATING MODE AIRLOOP F8 NW 0.252227 4357.24 0.000095
HEAT PUMP HEATING MODE AIRLOOP F8 SE 0.240647 4229.62 0.000092
HEAT PUMP HEATING MODE AIRLOOP F8 NE 0.196150 3527.42 0.000077
HEAT PUMP HEATING MODE AIRLOOP F8 N1 0.142119 2650.74 0.000058
HEAT PUMP HEATING MODE AIRLOOP F8 N2 0.140821 2631.74 0.000057
HEAT PUMP HEATING MODE AIRLOOP F8 S1 0.176030 3198.30 0.000070
HEAT PUMP HEATING MODE AIRLOOP F8 S2 0.176949 3211.20 0.000070
HEAT PUMP HEATING MODE AIRLOOP F9 SW 0.280215 4771.21 0.000104
HEAT PUMP HEATING MODE AIRLOOP F9 NW 0.260390 4485.99 0.000098
HEAT PUMP HEATING MODE AIRLOOP F9 SE 0.246581 4329.35 0.000095
HEAT PUMP HEATING MODE AIRLOOP F9 NE 0.199229 3583.63 0.000078
HEAT PUMP HEATING MODE AIRLOOP F9 N1 0.149336 2762.19 0.000060
HEAT PUMP HEATING MODE AIRLOOP F9 N2 0.148020 2742.96 0.000060
HEAT PUMP HEATING MODE AIRLOOP F9 S1 0.181084 3279.96 0.000072
HEAT PUMP HEATING MODE AIRLOOP F9 S2 0.182000 3292.82 0.000072
HEAT PUMP HEATING MODE AIRLOOP T SW 0.334258 5570.21 0.000122
HEAT PUMP HEATING MODE AIRLOOP T NW 0.306719 5157.42 0.000113
HEAT PUMP HEATING MODE AIRLOOP T SE 0.302281 5126.16 0.000112
HEAT PUMP HEATING MODE AIRLOOP T NE 0.242108 4216.68 0.000092
HEAT PUMP HEATING MODE AIRLOOP T N1 0.176197 3212.28 0.000070
HEAT PUMP HEATING MODE AIRLOOP T N2 0.176088 3214.81 0.000070
HEAT PUMP HEATING MODE AIRLOOP T S1 0.246278 4204.72 0.000092
HEAT PUMP HEATING MODE AIRLOOP T S2 0.247225 4217.84 0.000092


Coil:Heating:Electric

Nominal Capacity [W]
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW 3875.68
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW 3881.41
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE 4864.18
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE 3882.12
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 2939.41
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 2939.41
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 2930.57
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 2939.07
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW 3896.08
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW 3895.59
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE 3917.02
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE 3891.76
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 2724.90
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 2724.81
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 2728.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 2729.76
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW 3958.78
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW 3959.97
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE 3954.60
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE 3953.19
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 2724.73
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 2724.58
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 2724.43
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 2724.51
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW 4061.22
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW 4063.03
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE 4052.63
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE 4054.19
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 2776.51
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 2776.31
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 2775.29
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 2775.12
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW 4130.63
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW 4131.45
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE 4120.25
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE 4121.04
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 2804.23
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 2803.98
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 2803.93
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 2803.69
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW 4259.15
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW 4260.97
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE 4247.48
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE 4249.30
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 2897.38
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 2897.10
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 2896.07
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 2895.79
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW 4353.54
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW 4355.13
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE 4340.83
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE 4342.42
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 2960.61
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 2960.31
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 2959.55
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 2959.25
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW 4449.52
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW 4450.55
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE 4435.91
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE 4436.96
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 3028.55
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 3028.23
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 3028.04
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 3027.72
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW 4687.48
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW 4684.96
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE 4672.98
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE 4670.47
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 3228.12
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 3227.78
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 3230.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 3230.40
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW 5454.99
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW 5460.29
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE 5440.98
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE 5446.29
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 4048.30
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 4047.95
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 4040.26
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 4039.91


PlantLoop

Maximum Loop Flow Rate [m3/s] Plant Loop Volume [m3]
SHWSYS1 0.000289 0.325214
SINGLE WATER PLANT LOOP 0.006214 6.99


Boiler:HotWater

Design Water Flow Rate [m3/s]
CENTRAL BOILER 0.006214


WaterHeater:Mixed

Use Side Design Flow Rate [m3/s]
SHWSYS1 WATER HEATER 0.000289


EvaporativeFluidCooler:SingleSpeed

Design Water Flow Rate [m3/s] Fan Power at Design Air Flow Rate [W] Design Air Flow Rate [m3/s] U-Factor Times Area Value at Design Air Flow Rate [W/C]
CENTRAL TOWER 0.006214 2999.89 8.10 9073.01


Pump:ConstantSpeed

Rated Flow Rate [m3/s] Rated Power Consumption [W]
SHWSYS1 PUMP 0.000289 36.93
PLANT CIRC PUMP 0.006214 1584.95



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:07

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW3 |
G WWALL SWA GWINDOW2 |
G NWALL NWA GWINDOW4 |
G WWALL NWA GWINDOW6 |
G SWALL SEA GWINDOW1 |
G EWALL SEA GWINDOW8 |
G NWALL NEA GWINDOW5 |
G EWALL NEA GWINDOW7 |
G NWALL N1A GWINDOW9 |
G NWALL N2A GWINDOW10 |
G SWALL S1A GWINDOW11 |
G SWALL S2A GWINDOW12 |
G WWALL C GWINDOW13 |
G EWALL C ENTRANCE DOOR |
F2 WWALL SWA F2WINDOW2 |
F2 SWALL SWA F2WINDOW3 |
F2 NWALL NWA F2WINDOW4 |
F2 WWALL NWA F2WINDOW6 |
F2 EWALL SEA F2WINDOW8 |
F2 SWALL SEA F2WINDOW1 |
F2 NWALL NEA F2WINDOW5 |
F2 EWALL NEA F2WINDOW7 |
F2 NWALL N1A F2WINDOW9 |
F2 NWALL N2A F2WINDOW10 |
F2 SWALL S1A F2WINDOW11 |
F2 SWALL S2A F2WINDOW12 |
F2 WWALL C F2WINDOW13 |
F2 EWALL C F2WINDOW14 |
F3 WWALL SWA F3WINDOW2 |
F3 SWALL SWA F3WINDOW3 |
F3 NWALL NWA F3WINDOW4 |
F3 WWALL NWA F3WINDOW6 |
F3 EWALL SEA F3WINDOW8 |
F3 SWALL SEA F3WINDOW1 |
F3 NWALL NEA F3WINDOW5 |
F3 EWALL NEA F3WINDOW7 |
F3 NWALL N1A F3WINDOW9 |
F3 NWALL N2A F3WINDOW10 |
F3 SWALL S1A F3WINDOW11 |
F3 SWALL S2A F3WINDOW12 |
F3 WWALL C F3WINDOW13 |
F3 EWALL C F3WINDOW14 |
F4 WWALL SWA F4WINDOW2 |
F4 SWALL SWA F4WINDOW3 |
F4 NWALL NWA F4WINDOW4 |
F4 WWALL NWA F4WINDOW6 |
F4 EWALL SEA F4WINDOW8 |
F4 SWALL SEA F4WINDOW1 |
F4 NWALL NEA F4WINDOW5 |
F4 EWALL NEA F4WINDOW7 |
F4 NWALL N1A F4WINDOW9 |
F4 NWALL N2A F4WINDOW10 |
F4 SWALL S1A F4WINDOW11 |
F4 SWALL S2A F4WINDOW12 |
F4 WWALL C F4WINDOW13 |
F4 EWALL C F4WINDOW14 |
M WWALL SWA MWINDOW2 |
M SWALL SWA MWINDOW3 |
M NWALL NWA MWINDOW4 |
M WWALL NWA MWINDOW6 |
M EWALL SEA MWINDOW8 |
M SWALL SEA MWINDOW1 |
M NWALL NEA MWINDOW5 |
M EWALL NEA MWINDOW7 |
M NWALL N1A MWINDOW9 |
M NWALL N2A MWINDOW10 |
M SWALL S1A MWINDOW11 |
M SWALL S2A MWINDOW12 |
M WWALL C MWINDOW13 |
M EWALL C MWINDOW14 |
F6 WWALL SWA F6WINDOW2 |
F6 SWALL SWA F6WINDOW3 |
F6 NWALL NWA F6WINDOW4 |
F6 WWALL NWA F6WINDOW6 |
F6 EWALL SEA F6WINDOW8 |
F6 SWALL SEA F6WINDOW1 |
F6 NWALL NEA F6WINDOW5 |
F6 EWALL NEA F6WINDOW7 |
F6 NWALL N1A F6WINDOW9 |
F6 NWALL N2A F6WINDOW10 |
F6 SWALL S1A F6WINDOW11 |
F6 SWALL S2A F6WINDOW12 |
F6 WWALL C F6WINDOW13 |
F6 EWALL C F6WINDOW14 |
F7 WWALL SWA F7WINDOW2 |
F7 SWALL SWA F7WINDOW3 |
F7 NWALL NWA F7WINDOW4 |
F7 WWALL NWA F7WINDOW6 |
F7 EWALL SEA F7WINDOW8 |
F7 SWALL SEA F7WINDOW1 |
F7 NWALL NEA F7WINDOW5 |
F7 EWALL NEA F7WINDOW7 |
F7 NWALL N1A F7WINDOW9 |
F7 NWALL N2A F7WINDOW10 |
F7 SWALL S1A F7WINDOW11 |
F7 SWALL S2A F7WINDOW12 |
F7 WWALL C F7WINDOW13 |
F7 EWALL C F7WINDOW14 |
F8 WWALL SWA F8WINDOW2 |
F8 SWALL SWA F8WINDOW3 |
F8 NWALL NWA F8WINDOW4 |
F8 WWALL NWA F8WINDOW6 |
F8 EWALL SEA F8WINDOW8 |
F8 SWALL SEA F8WINDOW1 |
F8 NWALL NEA F8WINDOW5 |
F8 EWALL NEA F8WINDOW7 |
F8 NWALL N1A F8WINDOW9 |
F8 NWALL N2A F8WINDOW10 |
F8 SWALL S1A F8WINDOW11 |
F8 SWALL S2A F8WINDOW12 |
F8 WWALL C F8WINDOW13 |
F8 EWALL C F8WINDOW14 |
F9 WWALL SWA F9WINDOW2 |
F9 SWALL SWA F9WINDOW3 |
F9 NWALL NWA F9WINDOW4 |
F9 WWALL NWA F9WINDOW6 |
F9 EWALL SEA F9WINDOW8 |
F9 SWALL SEA F9WINDOW1 |
F9 NWALL NEA F9WINDOW5 |
F9 EWALL NEA F9WINDOW7 |
F9 NWALL N1A F9WINDOW9 |
F9 NWALL N2A F9WINDOW10 |
F9 SWALL S1A F9WINDOW11 |
F9 SWALL S2A F9WINDOW12 |
F9 WWALL C F9WINDOW13 |
F9 EWALL C F9WINDOW14 |
T WWALL SWA TWINDOW2 |
T SWALL SWA TWINDOW3 |
T NWALL NWA TWINDOW4 |
T WWALL NWA TWINDOW6 |
T EWALL SEA TWINDOW8 |
T SWALL SEA TWINDOW1 |
T NWALL NEA TWINDOW5 |
T EWALL NEA TWINDOW7 |
T NWALL N1A TWINDOW9 |
T NWALL N2A TWINDOW10 |
T SWALL S1A TWINDOW11 |
T SWALL S2A TWINDOW12 |
T WWALL C TWINDOW13 |
T EWALL C TWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:07

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -3.4
February 21.72 -4.2
March 21.98 2.67
April 22.26 7.47
May 22.93 13.73
June 24.05 18.63
July 24.33 22.03
August 24.28 20.69
September 24.02 16.55
October 22.52 9.72
November 21.91 6.03
December 21.71 -2.2
     
Annual Sum or Average 22.79 9.05
Minimum of Months 21.71 -4.2
Maximum of Months 24.33 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.85 2.67
April 21.96 7.47
May 22.69 13.73
June 24.00 18.63
July 24.33 22.03
August 24.26 20.69
September 23.77 16.55
October 22.03 9.72
November 21.72 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.65 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.33 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -3.4
February 21.75 -4.2
March 22.14 2.67
April 22.44 7.47
May 23.30 13.73
June 24.22 18.63
July 24.38 22.03
August 24.36 20.69
September 24.12 16.55
October 22.75 9.72
November 22.05 6.03
December 21.72 -2.2
     
Annual Sum or Average 22.92 9.05
Minimum of Months 21.71 -4.2
Maximum of Months 24.38 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.84 2.67
April 21.92 7.47
May 22.58 13.73
June 23.95 18.63
July 24.35 22.03
August 24.25 20.69
September 23.69 16.55
October 21.96 9.72
November 21.72 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.62 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.35 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.83 2.67
April 21.83 7.47
May 22.41 13.73
June 23.84 18.63
July 24.31 22.03
August 24.22 20.69
September 23.63 16.55
October 21.96 9.72
November 21.72 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.58 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.31 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.83 2.67
April 21.83 7.47
May 22.40 13.73
June 23.84 18.63
July 24.31 22.03
August 24.21 20.69
September 23.63 16.55
October 21.96 9.72
November 21.72 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.57 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.31 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -3.4
February 21.72 -4.2
March 21.98 2.67
April 22.20 7.47
May 22.78 13.73
June 23.96 18.63
July 24.32 22.03
August 24.26 20.69
September 24.04 16.55
October 22.59 9.72
November 21.96 6.03
December 21.72 -2.2
     
Annual Sum or Average 22.78 9.05
Minimum of Months 21.71 -4.2
Maximum of Months 24.32 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -3.4
February 21.72 -4.2
March 22.00 2.67
April 22.23 7.47
May 22.83 13.73
June 23.98 18.63
July 24.32 22.03
August 24.27 20.69
September 24.06 16.55
October 22.64 9.72
November 21.98 6.03
December 21.72 -2.2
     
Annual Sum or Average 22.79 9.05
Minimum of Months 21.71 -4.2
Maximum of Months 24.32 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 15.90 -3.4
February 15.75 -4.2
March 17.83 2.67
April 19.32 7.47
May 21.45 13.73
June 23.95 18.63
July 25.12 22.03
August 24.76 20.69
September 23.33 16.55
October 20.07 9.72
November 18.55 6.03
December 16.20 -2.2
     
Annual Sum or Average 20.21 9.05
Minimum of Months 15.75 -4.2
Maximum of Months 25.12 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SW APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.72 -3.4
February 21.73 -4.2
March 22.24 2.67
April 22.85 7.47
May 23.84 13.73
June 24.28 18.63
July 24.37 22.03
August 24.35 20.69
September 24.25 16.55
October 23.11 9.72
November 22.15 6.03
December 21.72 -2.2
     
Annual Sum or Average 23.06 9.05
Minimum of Months 21.72 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NW APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.99 2.67
April 22.32 7.47
May 23.59 13.73
June 24.23 18.63
July 24.38 22.03
August 24.34 20.69
September 24.05 16.55
October 22.36 9.72
November 21.77 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.85 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.38 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SE APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -3.4
February 21.73 -4.2
March 22.26 2.67
April 22.92 7.47
May 23.91 13.73
June 24.29 18.63
July 24.39 22.03
August 24.36 20.69
September 24.27 16.55
October 23.21 9.72
November 22.18 6.03
December 21.72 -2.2
     
Annual Sum or Average 23.09 9.05
Minimum of Months 21.71 -4.2
Maximum of Months 24.39 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NE APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.96 2.67
April 22.27 7.47
May 23.48 13.73
June 24.21 18.63
July 24.39 22.03
August 24.34 20.69
September 23.99 16.55
October 22.26 9.72
November 21.75 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.82 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.39 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N1 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.99 2.67
April 22.18 7.47
May 23.37 13.73
June 24.13 18.63
July 24.37 22.03
August 24.32 20.69
September 23.94 16.55
October 22.35 9.72
November 21.77 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.80 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N2 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.98 2.67
April 22.18 7.47
May 23.36 13.73
June 24.12 18.63
July 24.37 22.03
August 24.32 20.69
September 23.94 16.55
October 22.34 9.72
November 21.77 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.80 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S1 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 -3.4
February 21.75 -4.2
March 22.32 2.67
April 22.89 7.47
May 23.77 13.73
June 24.20 18.63
July 24.37 22.03
August 24.34 20.69
September 24.26 16.55
October 23.33 9.72
November 22.30 6.03
December 21.74 -2.2
     
Annual Sum or Average 23.09 9.05
Minimum of Months 21.73 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S2 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 -3.4
February 21.75 -4.2
March 22.33 2.67
April 22.91 7.47
May 23.79 13.73
June 24.21 18.63
July 24.37 22.03
August 24.34 20.69
September 24.26 16.55
October 23.35 9.72
November 22.30 6.03
December 21.74 -2.2
     
Annual Sum or Average 23.10 9.05
Minimum of Months 21.73 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 CORRIDOR

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.15 -3.4
February 21.14 -4.2
March 22.44 2.67
April 23.30 7.47
May 24.79 13.73
June 25.98 18.63
July 26.44 22.03
August 26.29 20.69
September 25.65 16.55
October 23.61 9.72
November 22.36 6.03
December 21.16 -2.2
     
Annual Sum or Average 23.71 9.05
Minimum of Months 21.14 -4.2
Maximum of Months 26.44 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SW APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.72 -3.4
February 21.73 -4.2
March 22.27 2.67
April 22.96 7.47
May 23.97 13.73
June 24.27 18.63
July 24.38 22.03
August 24.35 20.69
September 24.25 16.55
October 23.21 9.72
November 22.18 6.03
December 21.72 -2.2
     
Annual Sum or Average 23.09 9.05
Minimum of Months 21.72 -4.2
Maximum of Months 24.38 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NW APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 22.02 2.67
April 22.43 7.47
May 23.76 13.73
June 24.24 18.63
July 24.38 22.03
August 24.34 20.69
September 24.07 16.55
October 22.44 9.72
November 21.77 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.89 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.38 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SE APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -3.4
February 21.72 -4.2
March 22.23 2.67
April 22.95 7.47
May 23.96 13.73
June 24.27 18.63
July 24.39 22.03
August 24.36 20.69
September 24.25 16.55
October 23.21 9.72
November 22.16 6.03
December 21.72 -2.2
     
Annual Sum or Average 23.08 9.05
Minimum of Months 21.71 -4.2
Maximum of Months 24.39 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NE APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.98 2.67
April 22.38 7.47
May 23.67 13.73
June 24.21 18.63
July 24.39 22.03
August 24.35 20.69
September 24.02 16.55
October 22.34 9.72
November 21.75 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.86 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.39 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N1 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 22.03 2.67
April 22.35 7.47
May 23.64 13.73
June 24.15 18.63
July 24.38 22.03
August 24.33 20.69
September 23.99 16.55
October 22.49 9.72
November 21.79 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.86 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.38 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N2 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 22.03 2.67
April 22.35 7.47
May 23.63 13.73
June 24.15 18.63
July 24.38 22.03
August 24.33 20.69
September 23.98 16.55
October 22.48 9.72
November 21.79 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.86 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.38 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S1 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.74 -3.4
February 21.75 -4.2
March 22.41 2.67
April 23.07 7.47
May 23.95 13.73
June 24.21 18.63
July 24.37 22.03
August 24.34 20.69
September 24.27 16.55
October 23.52 9.72
November 22.37 6.03
December 21.74 -2.2
     
Annual Sum or Average 23.15 9.05
Minimum of Months 21.74 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S2 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.74 -3.4
February 21.75 -4.2
March 22.41 2.67
April 23.08 7.47
May 23.95 13.73
June 24.21 18.63
July 24.37 22.03
August 24.34 20.69
September 24.27 16.55
October 23.53 9.72
November 22.37 6.03
December 21.74 -2.2
     
Annual Sum or Average 23.16 9.05
Minimum of Months 21.74 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 CORRIDOR

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.58 -3.4
February 21.58 -4.2
March 22.89 2.67
April 23.78 7.47
May 25.32 13.73
June 26.19 18.63
July 26.58 22.03
August 26.45 20.69
September 25.88 16.55
October 24.03 9.72
November 22.71 6.03
December 21.55 -2.2
     
Annual Sum or Average 24.06 9.05
Minimum of Months 21.55 -4.2
Maximum of Months 26.58 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SW APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -3.4
February 21.73 -4.2
March 22.25 2.67
April 22.96 7.47
May 23.98 13.73
June 24.27 18.63
July 24.38 22.03
August 24.35 20.69
September 24.27 16.55
October 23.21 9.72
November 22.17 6.03
December 21.72 -2.2
     
Annual Sum or Average 23.09 9.05
Minimum of Months 21.71 -4.2
Maximum of Months 24.38 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NW APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 22.02 2.67
April 22.46 7.47
May 23.80 13.73
June 24.23 18.63
July 24.38 22.03
August 24.34 20.69
September 24.10 16.55
October 22.46 9.72
November 21.78 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.89 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.38 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SE APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -3.4
February 21.72 -4.2
March 22.20 2.67
April 22.93 7.47
May 23.96 13.73
June 24.26 18.63
July 24.39 22.03
August 24.36 20.69
September 24.27 16.55
October 23.19 9.72
November 22.15 6.03
December 21.71 -2.2
     
Annual Sum or Average 23.08 9.05
Minimum of Months 21.71 -4.2
Maximum of Months 24.39 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NE APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.99 2.67
April 22.41 7.47
May 23.72 13.73
June 24.21 18.63
July 24.39 22.03
August 24.35 20.69
September 24.05 16.55
October 22.35 9.72
November 21.76 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.87 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.39 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N1 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 22.04 2.67
April 22.42 7.47
May 23.72 13.73
June 24.15 18.63
July 24.38 22.03
August 24.33 20.69
September 24.03 16.55
October 22.54 9.72
November 21.80 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.88 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.38 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N2 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 22.04 2.67
April 22.42 7.47
May 23.72 13.73
June 24.15 18.63
July 24.38 22.03
August 24.33 20.69
September 24.03 16.55
October 22.53 9.72
November 21.80 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.88 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.38 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S1 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 -3.4
February 21.75 -4.2
March 22.42 2.67
April 23.11 7.47
May 23.99 13.73
June 24.21 18.63
July 24.37 22.03
August 24.34 20.69
September 24.29 16.55
October 23.56 9.72
November 22.38 6.03
December 21.74 -2.2
     
Annual Sum or Average 23.17 9.05
Minimum of Months 21.73 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S2 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 -3.4
February 21.75 -4.2
March 22.41 2.67
April 23.11 7.47
May 23.99 13.73
June 24.21 18.63
July 24.37 22.03
August 24.34 20.69
September 24.29 16.55
October 23.56 9.72
November 22.38 6.03
December 21.74 -2.2
     
Annual Sum or Average 23.17 9.05
Minimum of Months 21.73 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 CORRIDOR

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.71 -4.2
March 23.03 2.67
April 23.95 7.47
May 25.51 13.73
June 26.29 18.63
July 26.68 22.03
August 26.54 20.69
September 25.99 16.55
October 24.18 9.72
November 22.84 6.03
December 21.68 -2.2
     
Annual Sum or Average 24.19 9.05
Minimum of Months 21.68 -4.2
Maximum of Months 26.68 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -3.4
February 21.72 -4.2
March 22.23 2.67
April 22.94 7.47
May 23.97 13.73
June 24.25 18.63
July 24.37 22.03
August 24.35 20.69
September 24.27 16.55
October 23.18 9.72
November 22.16 6.03
December 21.72 -2.2
     
Annual Sum or Average 23.08 9.05
Minimum of Months 21.71 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 22.02 2.67
April 22.45 7.47
May 23.79 13.73
June 24.22 18.63
July 24.38 22.03
August 24.34 20.69
September 24.09 16.55
October 22.45 9.72
November 21.78 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.89 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.38 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -3.4
February 21.72 -4.2
March 22.19 2.67
April 22.91 7.47
May 23.94 13.73
June 24.24 18.63
July 24.39 22.03
August 24.36 20.69
September 24.26 16.55
October 23.16 9.72
November 22.13 6.03
December 21.71 -2.2
     
Annual Sum or Average 23.07 9.05
Minimum of Months 21.71 -4.2
Maximum of Months 24.39 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.99 2.67
April 22.41 7.47
May 23.71 13.73
June 24.20 18.63
July 24.39 22.03
August 24.35 20.69
September 24.04 16.55
October 22.35 9.72
November 21.76 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.86 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.39 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 22.04 2.67
April 22.44 7.47
May 23.74 13.73
June 24.14 18.63
July 24.38 22.03
August 24.33 20.69
September 24.03 16.55
October 22.56 9.72
November 21.81 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.89 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.38 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 22.04 2.67
April 22.44 7.47
May 23.73 13.73
June 24.14 18.63
July 24.38 22.03
August 24.33 20.69
September 24.03 16.55
October 22.55 9.72
November 21.81 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.89 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.38 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 -3.4
February 21.75 -4.2
March 22.41 2.67
April 23.11 7.47
May 23.99 13.73
June 24.20 18.63
July 24.37 22.03
August 24.34 20.69
September 24.29 16.55
October 23.56 9.72
November 22.38 6.03
December 21.74 -2.2
     
Annual Sum or Average 23.16 9.05
Minimum of Months 21.73 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 -3.4
February 21.75 -4.2
March 22.41 2.67
April 23.11 7.47
May 23.99 13.73
June 24.20 18.63
July 24.37 22.03
August 24.34 20.69
September 24.29 16.55
October 23.56 9.72
November 22.38 6.03
December 21.74 -2.2
     
Annual Sum or Average 23.16 9.05
Minimum of Months 21.73 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.37 -3.4
February 22.35 -4.2
March 23.66 2.67
April 24.57 7.47
May 26.13 13.73
June 26.88 18.63
July 27.28 22.03
August 27.14 20.69
September 26.60 16.55
October 24.81 9.72
November 23.49 6.03
December 22.34 -2.2
     
Annual Sum or Average 24.81 9.05
Minimum of Months 22.34 -4.2
Maximum of Months 27.28 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SW APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -3.4
February 21.72 -4.2
March 22.18 2.67
April 22.84 7.47
May 23.88 13.73
June 24.22 18.63
July 24.37 22.03
August 24.34 20.69
September 24.24 16.55
October 23.05 9.72
November 22.11 6.03
December 21.71 -2.2
     
Annual Sum or Average 23.04 9.05
Minimum of Months 21.71 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NW APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.99 2.67
April 22.35 7.47
May 23.68 13.73
June 24.17 18.63
July 24.37 22.03
August 24.33 20.69
September 24.02 16.55
October 22.35 9.72
November 21.76 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.85 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SE APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -3.4
February 21.71 -4.2
March 22.14 2.67
April 22.81 7.47
May 23.85 13.73
June 24.21 18.63
July 24.38 22.03
August 24.35 20.69
September 24.23 16.55
October 23.03 9.72
November 22.08 6.03
December 21.71 -2.2
     
Annual Sum or Average 23.03 9.05
Minimum of Months 21.71 -4.2
Maximum of Months 24.38 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NE APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.97 2.67
April 22.31 7.47
May 23.60 13.73
June 24.15 18.63
July 24.39 22.03
August 24.34 20.69
September 23.97 16.55
October 22.26 9.72
November 21.74 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.83 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.39 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N1 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 22.02 2.67
April 22.34 7.47
May 23.63 13.73
June 24.09 18.63
July 24.37 22.03
August 24.32 20.69
September 23.96 16.55
October 22.44 9.72
November 21.79 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.84 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N2 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 22.02 2.67
April 22.34 7.47
May 23.62 13.73
June 24.09 18.63
July 24.38 22.03
August 24.32 20.69
September 23.95 16.55
October 22.43 9.72
November 21.78 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.84 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.38 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S1 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 -3.4
February 21.74 -4.2
March 22.33 2.67
April 23.01 7.47
May 23.91 13.73
June 24.16 18.63
July 24.37 22.03
August 24.34 20.69
September 24.26 16.55
October 23.43 9.72
November 22.31 6.03
December 21.73 -2.2
     
Annual Sum or Average 23.12 9.05
Minimum of Months 21.73 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S2 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 -3.4
February 21.74 -4.2
March 22.33 2.67
April 23.01 7.47
May 23.91 13.73
June 24.16 18.63
July 24.37 22.03
August 24.34 20.69
September 24.26 16.55
October 23.43 9.72
November 22.31 6.03
December 21.73 -2.2
     
Annual Sum or Average 23.12 9.05
Minimum of Months 21.73 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 CORRIDOR

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.65 -3.4
February 21.64 -4.2
March 22.95 2.67
April 23.84 7.47
May 25.42 13.73
June 26.22 18.63
July 26.66 22.03
August 26.52 20.69
September 25.93 16.55
October 24.07 9.72
November 22.78 6.03
December 21.62 -2.2
     
Annual Sum or Average 24.12 9.05
Minimum of Months 21.62 -4.2
Maximum of Months 26.66 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SW APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -3.4
February 21.71 -4.2
March 22.15 2.67
April 22.76 7.47
May 23.82 13.73
June 24.19 18.63
July 24.37 22.03
August 24.34 20.69
September 24.21 16.55
October 22.95 9.72
November 22.07 6.03
December 21.71 -2.2
     
Annual Sum or Average 23.01 9.05
Minimum of Months 21.71 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NW APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.98 2.67
April 22.28 7.47
May 23.60 13.73
June 24.14 18.63
July 24.37 22.03
August 24.32 20.69
September 23.97 16.55
October 22.28 9.72
November 21.75 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.82 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SE APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -3.4
February 21.71 -4.2
March 22.11 2.67
April 22.73 7.47
May 23.78 13.73
June 24.18 18.63
July 24.38 22.03
August 24.35 20.69
September 24.21 16.55
October 22.93 9.72
November 22.05 6.03
December 21.71 -2.2
     
Annual Sum or Average 22.99 9.05
Minimum of Months 21.71 -4.2
Maximum of Months 24.38 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NE APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.95 2.67
April 22.25 7.47
May 23.51 13.73
June 24.11 18.63
July 24.39 22.03
August 24.33 20.69
September 23.91 16.55
October 22.19 9.72
November 21.74 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.80 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.39 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N1 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 22.00 2.67
April 22.26 7.47
May 23.54 13.73
June 24.05 18.63
July 24.37 22.03
August 24.31 20.69
September 23.90 16.55
October 22.36 9.72
November 21.77 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.81 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N2 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 22.00 2.67
April 22.26 7.47
May 23.53 13.73
June 24.05 18.63
July 24.37 22.03
August 24.31 20.69
September 23.90 16.55
October 22.35 9.72
November 21.77 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.81 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S1 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.72 -3.4
February 21.73 -4.2
March 22.28 2.67
April 22.93 7.47
May 23.84 13.73
June 24.12 18.63
July 24.36 22.03
August 24.33 20.69
September 24.24 16.55
October 23.32 9.72
November 22.27 6.03
December 21.73 -2.2
     
Annual Sum or Average 23.08 9.05
Minimum of Months 21.72 -4.2
Maximum of Months 24.36 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S2 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.72 -3.4
February 21.73 -4.2
March 22.28 2.67
April 22.93 7.47
May 23.84 13.73
June 24.12 18.63
July 24.36 22.03
August 24.33 20.69
September 24.25 16.55
October 23.32 9.72
November 22.27 6.03
December 21.73 -2.2
     
Annual Sum or Average 23.08 9.05
Minimum of Months 21.72 -4.2
Maximum of Months 24.36 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 CORRIDOR

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.50 -3.4
February 21.48 -4.2
March 22.79 2.67
April 23.65 7.47
May 25.24 13.73
June 26.09 18.63
July 26.57 22.03
August 26.43 20.69
September 25.80 16.55
October 23.87 9.72
November 22.62 6.03
December 21.47 -2.2
     
Annual Sum or Average 23.97 9.05
Minimum of Months 21.47 -4.2
Maximum of Months 26.57 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SW APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -3.4
February 21.71 -4.2
March 22.12 2.67
April 22.69 7.47
May 23.75 13.73
June 24.16 18.63
July 24.36 22.03
August 24.33 20.69
September 24.18 16.55
October 22.86 9.72
November 22.04 6.03
December 21.71 -2.2
     
Annual Sum or Average 22.98 9.05
Minimum of Months 21.71 -4.2
Maximum of Months 24.36 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NW APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.97 2.67
April 22.22 7.47
May 23.52 13.73
June 24.11 18.63
July 24.37 22.03
August 24.32 20.69
September 23.92 16.55
October 22.22 9.72
November 21.75 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.80 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SE APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -3.4
February 21.71 -4.2
March 22.09 2.67
April 22.66 7.47
May 23.71 13.73
June 24.15 18.63
July 24.38 22.03
August 24.34 20.69
September 24.18 16.55
October 22.84 9.72
November 22.01 6.03
December 21.71 -2.2
     
Annual Sum or Average 22.97 9.05
Minimum of Months 21.71 -4.2
Maximum of Months 24.38 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NE APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.94 2.67
April 22.20 7.47
May 23.42 13.73
June 24.08 18.63
July 24.39 22.03
August 24.33 20.69
September 23.86 16.55
October 22.14 9.72
November 21.73 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.77 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.39 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N1 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.99 2.67
April 22.20 7.47
May 23.46 13.73
June 24.02 18.63
July 24.37 22.03
August 24.30 20.69
September 23.85 16.55
October 22.29 9.72
November 21.77 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.79 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N2 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.99 2.67
April 22.20 7.47
May 23.44 13.73
June 24.01 18.63
July 24.37 22.03
August 24.30 20.69
September 23.84 16.55
October 22.28 9.72
November 21.76 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.78 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S1 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.72 -3.4
February 21.73 -4.2
March 22.23 2.67
April 22.85 7.47
May 23.78 13.73
June 24.09 18.63
July 24.36 22.03
August 24.32 20.69
September 24.22 16.55
October 23.20 9.72
November 22.23 6.03
December 21.72 -2.2
     
Annual Sum or Average 23.05 9.05
Minimum of Months 21.72 -4.2
Maximum of Months 24.36 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S2 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.72 -3.4
February 21.73 -4.2
March 22.23 2.67
April 22.85 7.47
May 23.78 13.73
June 24.09 18.63
July 24.36 22.03
August 24.33 20.69
September 24.22 16.55
October 23.21 9.72
November 22.23 6.03
December 21.72 -2.2
     
Annual Sum or Average 23.05 9.05
Minimum of Months 21.72 -4.2
Maximum of Months 24.36 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 CORRIDOR

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.41 -3.4
February 21.40 -4.2
March 22.70 2.67
April 23.54 7.47
May 25.13 13.73
June 26.04 18.63
July 26.57 22.03
August 26.41 20.69
September 25.73 16.55
October 23.74 9.72
November 22.53 6.03
December 21.38 -2.2
     
Annual Sum or Average 23.90 9.05
Minimum of Months 21.38 -4.2
Maximum of Months 26.57 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SW APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -3.4
February 21.71 -4.2
March 22.09 2.67
April 22.60 7.47
May 23.66 13.73
June 24.13 18.63
July 24.36 22.03
August 24.33 20.69
September 24.14 16.55
October 22.76 9.72
November 22.00 6.03
December 21.71 -2.2
     
Annual Sum or Average 22.94 9.05
Minimum of Months 21.71 -4.2
Maximum of Months 24.36 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NW APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.95 2.67
April 22.18 7.47
May 23.41 13.73
June 24.07 18.63
July 24.36 22.03
August 24.31 20.69
September 23.85 16.55
October 22.17 9.72
November 21.74 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.77 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.36 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SE APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 22.07 2.67
April 22.58 7.47
May 23.62 13.73
June 24.12 18.63
July 24.38 22.03
August 24.34 20.69
September 24.14 16.55
October 22.74 9.72
November 21.98 6.03
December 21.71 -2.2
     
Annual Sum or Average 22.93 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.38 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NE APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.93 2.67
April 22.15 7.47
May 23.31 13.73
June 24.05 18.63
July 24.39 22.03
August 24.32 20.69
September 23.78 16.55
October 22.09 9.72
November 21.73 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.74 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.39 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N1 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.98 2.67
April 22.15 7.47
May 23.35 13.73
June 23.98 18.63
July 24.36 22.03
August 24.30 20.69
September 23.77 16.55
October 22.22 9.72
November 21.76 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.75 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.36 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N2 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.98 2.67
April 22.15 7.47
May 23.34 13.73
June 23.98 18.63
July 24.37 22.03
August 24.30 20.69
September 23.77 16.55
October 22.21 9.72
November 21.76 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.75 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.37 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S1 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.72 -3.4
February 21.72 -4.2
March 22.18 2.67
April 22.75 7.47
May 23.69 13.73
June 24.06 18.63
July 24.36 22.03
August 24.32 20.69
September 24.19 16.55
October 23.05 9.72
November 22.17 6.03
December 21.72 -2.2
     
Annual Sum or Average 23.00 9.05
Minimum of Months 21.72 -4.2
Maximum of Months 24.36 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S2 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.72 -3.4
February 21.72 -4.2
March 22.18 2.67
April 22.75 7.47
May 23.69 13.73
June 24.06 18.63
July 24.36 22.03
August 24.32 20.69
September 24.19 16.55
October 23.06 9.72
November 22.17 6.03
December 21.72 -2.2
     
Annual Sum or Average 23.00 9.05
Minimum of Months 21.72 -4.2
Maximum of Months 24.36 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 CORRIDOR

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.22 -3.4
February 21.20 -4.2
March 22.54 2.67
April 23.40 7.47
May 25.01 13.73
June 26.04 18.63
July 26.62 22.03
August 26.44 20.69
September 25.66 16.55
October 23.58 9.72
November 22.38 6.03
December 21.20 -2.2
     
Annual Sum or Average 23.79 9.05
Minimum of Months 21.20 -4.2
Maximum of Months 26.62 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.72 -3.4
February 21.72 -4.2
March 22.09 2.67
April 22.46 7.47
May 23.30 13.73
June 23.98 18.63
July 24.33 22.03
August 24.27 20.69
September 23.91 16.55
October 22.57 9.72
November 21.96 6.03
December 21.72 -2.2
     
Annual Sum or Average 22.84 9.05
Minimum of Months 21.72 -4.2
Maximum of Months 24.33 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.94 2.67
April 22.20 7.47
May 23.11 13.73
June 23.93 18.63
July 24.33 22.03
August 24.24 20.69
September 23.61 16.55
October 22.13 9.72
November 21.75 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.70 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.33 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -3.4
February 21.71 -4.2
March 22.07 2.67
April 22.45 7.47
May 23.29 13.73
June 23.97 18.63
July 24.35 22.03
August 24.28 20.69
September 23.90 16.55
October 22.56 9.72
November 21.94 6.03
December 21.72 -2.2
     
Annual Sum or Average 22.84 9.05
Minimum of Months 21.71 -4.2
Maximum of Months 24.35 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.91 2.67
April 22.19 7.47
May 23.05 13.73
June 23.89 18.63
July 24.35 22.03
August 24.24 20.69
September 23.54 16.55
October 22.06 9.72
November 21.73 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.68 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.35 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.94 2.67
April 22.15 7.47
May 23.07 13.73
June 23.84 18.63
July 24.33 22.03
August 24.22 20.69
September 23.52 16.55
October 22.12 9.72
November 21.75 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.68 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.33 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -3.4
February 21.70 -4.2
March 21.94 2.67
April 22.15 7.47
May 23.06 13.73
June 23.84 18.63
July 24.33 22.03
August 24.22 20.69
September 23.51 16.55
October 22.12 9.72
November 21.75 6.03
December 21.70 -2.2
     
Annual Sum or Average 22.68 9.05
Minimum of Months 21.70 -4.2
Maximum of Months 24.33 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 -3.4
February 21.74 -4.2
March 22.17 2.67
April 22.56 7.47
May 23.39 13.73
June 23.95 18.63
July 24.33 22.03
August 24.27 20.69
September 23.99 16.55
October 22.78 9.72
November 22.07 6.03
December 21.73 -2.2
     
Annual Sum or Average 22.90 9.05
Minimum of Months 21.73 -4.2
Maximum of Months 24.33 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 -3.4
February 21.74 -4.2
March 22.17 2.67
April 22.56 7.47
May 23.39 13.73
June 23.95 18.63
July 24.33 22.03
August 24.27 20.69
September 23.99 16.55
October 22.78 9.72
November 22.07 6.03
December 21.73 -2.2
     
Annual Sum or Average 22.90 9.05
Minimum of Months 21.73 -4.2
Maximum of Months 24.33 22.03



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2018-10-19 09:40:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.96 -3.4
February 20.96 -4.2
March 22.52 2.67
April 23.60 7.47
May 25.30 13.73
June 26.61 18.63
July 27.36 22.03
August 27.07 20.69
September 25.99 16.55
October 23.67 9.72
November 22.36 6.03
December 20.98 -2.2
     
Annual Sum or Average 23.96 9.05
Minimum of Months 20.96 -4.2
Maximum of Months 27.36 22.03



Table of Contents

Report: COMPONENTS OF PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2018-10-19 09:40:07

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY {AT MAX/MIN} [W] HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W]
January 0.276329E+12 149775.100 23-JAN-18:00 22204.399 56867.515 18118.972 39096.343 0.000 10720.100 1621.881 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
February 0.252486E+12 168051.989 06-FEB-18:00 22204.399 56867.515 18118.972 57373.233 0.000 10720.100 1621.881 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
March 0.236035E+12 138072.032 15-MAR-17:15 22204.399 56867.515 18118.972 0.000 36619.392 0.000 1621.881 1494.236 0.000 0.000 0.000 0.000 0.000 0.000 0.000
April 0.206953E+12 126276.414 08-APR-19:00 25049.151 49704.829 18118.972 20115.908 0.000 10720.100 1621.881 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
May 0.208039E+12 133685.310 14-MAY-15:15 14808.046 44495.955 18118.972 0.000 51775.112 0.000 1621.881 2061.289 0.000 0.000 0.000 0.000 0.000 0.000 0.000
June 0.241284E+12 176256.099 27-JUN-17:15 22204.399 56867.515 18118.972 0.000 73456.261 0.000 1621.881 2841.434 0.000 0.000 0.000 0.000 0.000 0.000 0.000
July 0.296459E+12 175857.984 11-JUL-17:15 22204.399 56867.515 18118.972 0.000 73187.472 0.000 1621.881 2712.108 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 0.275703E+12 177237.968 13-AUG-19:30 25049.151 49704.829 18118.972 0.000 68352.219 10720.100 1621.881 2725.244 0.000 0.000 0.000 0.000 0.000 0.000 0.000
September 0.223572E+12 170720.315 16-SEP-17:15 22204.399 56867.515 18118.972 0.000 68252.868 0.000 1621.881 2509.043 0.000 0.000 0.000 0.000 0.000 0.000 0.000
October 0.211253E+12 125009.498 25-OCT-17:00 22204.399 56867.515 18118.972 14330.742 0.000 10720.100 1621.881 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
November 0.222710E+12 131502.268 16-NOV-18:15 22204.399 56867.515 18118.972 20823.764 0.000 10720.100 1621.881 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
December 0.275839E+12 158336.609 09-DEC-18:15 22204.399 56867.515 18118.972 47658.105 0.000 10720.100 1621.881 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
                                     
Annual Sum or Average 0.292666E+13                     0.000 0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.206953E+12 125009.498   14808.046 44495.955 18118.972 0.000 0.000 0.000 1621.881 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.296459E+12 177237.968   25049.151 56867.515 18118.972 57373.233 73456.261 10720.100 1621.881 2841.434 0.000 0.000 0.000 0.000 0.000 0.000 0.000



Table of Contents

Report: COMPONENTS OF PEAK GAS DEMAND

For: Meter

Timestamp: 2018-10-19 09:40:07

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC [Invalid/Undefined] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT {AT MAX/MIN} [W] WATERSYSTEMS:GAS {AT MAX/MIN} [W] WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] HEATING:GAS {AT MAX/MIN} [W]
January 0.386307E+12 308095.386 12-JAN-08:30 0.000 0.000 0.000 308095.386 88290.510 88290.510 219804.876
February 0.368921E+12 329207.695 06-FEB-09:45 0.000 0.000 0.000 329207.695 83981.723 83981.723 245225.971
March 0.230973E+12 220392.948 06-MAR-06:45 0.000 0.000 0.000 220392.948 85035.486 85035.486 135357.462
April 0.142270E+12 204126.253 16-APR-07:15 0.000 0.000 0.000 204126.253 87465.560 87465.560 116660.693
May 0.105146E+12 113844.956 29-MAY-15:15 0.000 0.000 0.000 113844.956 40186.381 40186.381 73658.575
June 0.950699E+11 84770.570 01-JUN-06:00 0.000 0.000 0.000 84770.570 84770.570 84770.570 0.000
July 0.935311E+11 82880.787 01-JUL-06:00 0.000 0.000 0.000 82880.787 82880.787 82880.787 0.000
August 0.917364E+11 81754.726 02-AUG-06:00 0.000 0.000 0.000 81754.726 81754.726 81754.726 0.000
September 0.903728E+11 82785.025 30-SEP-06:00 0.000 0.000 0.000 82785.025 82785.025 82785.025 0.000
October 0.113956E+12 144398.664 30-OCT-05:45 0.000 0.000 0.000 144398.664 80280.854 80280.854 64117.809
November 0.183408E+12 185989.421 27-NOV-09:15 0.000 0.000 0.000 185989.421 78533.060 78533.060 107456.361
December 0.377448E+12 303341.447 26-DEC-07:00 0.000 0.000 0.000 303341.447 88895.656 88895.656 214445.791
                     
Annual Sum or Average 0.227914E+13     0.000 0.000 0.000        
Minimum of Months 0.903728E+11 81754.726   0.000 0.000 0.000 81754.726 40186.381 40186.381 0.000
Maximum of Months 0.386307E+12 329207.695   0.000 0.000 0.000 329207.695 88895.656 88895.656 245225.971