Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:37

Tabular Output Report in Format: HTML

Building: High-Rise Apartment

Environment: Tampa-MacDill AFB FL USA TMY3 WMO#=747880

Simulation Timestamp: 2018-10-19 09:40:08


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 4477.69 571.39 634.24
Net Site Energy 4477.69 571.39 634.24
Total Source Energy 12291.14 1568.45 1740.98
Net Source Energy 12291.14 1568.45 1740.98


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 7836.48
Net Conditioned Building Area 7059.89
Unconditioned Building Area 776.58


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 10.11 13.16 0.00 0.00 0.00 0.00
Cooling 1107.49 0.00 0.00 0.00 0.00 0.00
Interior Lighting 416.41 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 168.41 0.00 0.00 0.00 0.00 0.00
Interior Equipment 1131.09 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 604.09 0.00 0.00 0.00 0.00 0.00
Pumps 56.82 0.00 0.00 0.00 0.00 0.00
Heat Rejection 55.24 0.00 0.00 0.00 0.00 2777.43
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 894.05 0.00 0.00 0.00 4778.51
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 3570.48 907.21 0.00 0.00 0.00 7555.94
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating Boiler 0.00 13.16 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
  Other 10.11 0.00 0.00 0.00 0.00 0.00
Cooling General 1107.49 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 348.50 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 67.92 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 168.41 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 1131.09 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 604.09 0.00 0.00 0.00 0.00 0.00
Pumps General 56.82 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 55.24 0.00 0.00 0.00 0.00 2777.43
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 894.05 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 4778.51
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 82.84 0.00 0.00 0.00 0.00 0.00
HVAC 259.74 128.50 0.00 0.00 0.00 1.07
Other 160.21 0.00 0.00 0.00 0.00 0.00
Total 505.74 128.50 0.00 0.00 0.00 1.07


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 74.63 0.00 0.00 0.00 0.00 0.00
HVAC 234.00 115.77 0.00 0.00 0.00 0.96
Other 144.34 0.00 0.00 0.00 0.00 0.00
Total 455.62 115.77 0.00 0.00 0.00 0.96


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 3570.48 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 3570.48 100.00
     
Total On-Site and Utility Electric Sources 3570.48 100.00
Total Electricity End Uses 3570.48 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 7555.94 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 7555.94 100.00
Total Water End Uses 7555.94 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 18.75
Time Setpoint Not Met During Occupied Cooling 565.00
Time Not Comfortable Based on Simple ASHRAE 55-2004 3841.75


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |

COMPONENTS OF PEAK ELECTRICAL DEMAND

| Meter |

COMPONENTS OF PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:37
RunPeriod Tampa-MacDill AFB FL USA TMY3 WMO#=747880
Weather File Tampa-MacDill AFB FL USA TMY3 WMO#=747880
Latitude [deg] 27.85
Longitude [deg] -82.5
Elevation [m] 8.00
Time Zone -5.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3855.02 1411.96 515.55 1411.96 515.55
Window Opening Area [m2] 1150.39 423.59 152.73 423.59 150.48
Window-Wall Ratio [%] 29.84 30.00 29.62 30.00 29.19


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3752.84 1411.96 464.46 1411.96 464.46
Window Opening Area [m2] 1125.85 423.59 139.34 423.59 139.34
Window-Wall Ratio [%] 30.00 30.00 30.00 30.00 30.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
OFFICE 88.25 Yes Yes 268.96 1.00 58.52 17.56 23.8959 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 4.47 8.5250   0.0000
F2 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F2 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F2 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F2 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F2 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F2 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F2 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F2 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F2 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   0.0000
F3 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F3 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F3 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F3 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F3 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F3 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F3 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F3 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F3 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   0.0000
F4 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F4 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F4 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F4 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F4 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F4 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F4 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F4 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F4 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   0.0000
M SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
M CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 17.0500   0.0000
F6 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F6 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F6 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F6 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F6 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F6 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F6 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F6 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F6 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   0.0000
F7 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F7 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F7 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F7 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F7 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F7 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F7 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F7 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F7 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   0.0000
F8 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F8 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F8 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F8 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F8 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F8 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F8 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F8 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F8 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   0.0000
F9 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F9 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F9 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F9 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
F9 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F9 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F9 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
F9 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
F9 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   0.0000
T SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 14.4236 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 14.4236 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 14.4236 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 8.5250   263.6661
Total 7836.48     23884.04   3855.02 1150.39 14.0302 39.48 8.6219
Conditioned Total 7059.89     21517.16   3752.84 1125.85 14.5420 35.57 6.6700
Unconditioned Total 776.58     2366.87   102.18 24.54 9.3775   26.3666
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 10-AUG-19:00 05-FEB-07:15 - - - 09-SEP-17:15
Heating 0.00 100597.46 0.00 0.00 0.00 0.00
Cooling 84175.21 0.00 0.00 0.00 0.00 0.00
Interior Lighting 25049.15 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 10720.10 0.00 0.00 0.00 0.00 0.00
Interior Equipment 49704.83 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 19155.52 0.00 0.00 0.00 0.00 0.00
Pumps 1860.65 0.00 0.00 0.00 0.00 0.00
Heat Rejection 3451.82 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 79131.82 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 195062.84 179729.28 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating Boiler 0.00 100597.46 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 84175.21 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 20603.34 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 4445.81 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 10720.10 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 49704.83 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 19155.52 0.00 0.00 0.00 0.00 0.00
Pumps General 1860.65 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 3451.82 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 79131.82 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 32.01 14.27 0.00 0.00 0.00
Cooling 3507.41 0.00 0.00 0.00 0.00
Interior Lighting 1318.78 0.00 0.00 0.00 0.00
Exterior Lighting 533.35 0.00 0.00 0.00 0.00
Interior Equipment 3582.17 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 1913.15 0.00 0.00 0.00 0.00
Pumps 179.96 0.00 0.00 0.00 0.00
Heat Rejection 174.94 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 969.15 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 11307.72 983.42 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 4.53 2.02 0.00 0.00 0.00
Cooling 496.81 0.00 0.00 0.00 0.00
Interior Lighting 186.80 0.00 0.00 0.00 0.00
Exterior Lighting 75.55 0.00 0.00 0.00 0.00
Interior Equipment 507.40 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 270.99 0.00 0.00 0.00 0.00
Pumps 25.49 0.00 0.00 0.00 0.00
Heat Rejection 24.78 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 137.28 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1601.68 139.30 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 4.53 2.02 0.00 0.00 0.00
Cooling 496.81 0.00 0.00 0.00 0.00
Interior Lighting 186.80 0.00 0.00 0.00 0.00
Exterior Lighting 75.55 0.00 0.00 0.00 0.00
Interior Equipment 507.40 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 270.99 0.00 0.00 0.00 0.00
Pumps 25.49 0.00 0.00 0.00 0.00
Heat Rejection 24.78 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 137.28 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1601.68 139.30 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 4.60 0.00 4.60 Wetbulb [C] 2.50 10.00
TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 33.90 7.90 25.10 Wetbulb [C] 3.10 270.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 270.00 180.00  
F2 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F2 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F2 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F2 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F2 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F2 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F3 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F3 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F3 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F3 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F3 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F3 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F4 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F4 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F4 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F4 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F4 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F4 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
M WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F6 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F6 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F6 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F6 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F6 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F6 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F7 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F7 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F7 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F7 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F7 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F7 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F8 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F8 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F8 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F8 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F8 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F8 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F9 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F9 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F9 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F9 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F9 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F9 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.55 0.269 0.283 88.25 0.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.55 0.269 0.283 88.25 0.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.55 0.269 0.283 88.25 0.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.55 0.269 0.283 88.25 0.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.55 0.269 0.283 88.25 0.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.55 0.269 0.283 88.25 0.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.55 0.269 0.283 88.25 0.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.55 0.269 0.283 88.25 0.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.55 0.269 0.283 77.66 0.00 0.00  


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G SWALL SWA 180.00 90.00 S
GWINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No G WWALL SWA 270.00 90.00 W
GWINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G NWALL NWA 0.00 90.00 N
GWINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No G WWALL NWA 270.00 90.00 W
GWINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G SWALL SEA 180.00 90.00 S
GWINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No G EWALL SEA 90.00 90.00 E
GWINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G NWALL NEA 0.00 90.00 N
GWINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No G EWALL NEA 90.00 90.00 E
GWINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G NWALL N1A 0.00 90.00 N
GWINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G NWALL N2A 0.00 90.00 N
GWINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G SWALL S1A 180.00 90.00 S
GWINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G SWALL S2A 180.00 90.00 S
GWINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No G WWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.72_SHGC_0.25 3.36 0.00 0.00 3.36 3.36 4.600 0.293 0.130     No G EWALL C 90.00 90.00 E
F2WINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F2 WWALL SWA 270.00 90.00 W
F2WINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 SWALL SWA 180.00 90.00 S
F2WINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 NWALL NWA 0.00 90.00 N
F2WINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F2 WWALL NWA 270.00 90.00 W
F2WINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F2 EWALL SEA 90.00 90.00 E
F2WINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 SWALL SEA 180.00 90.00 S
F2WINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 NWALL NEA 0.00 90.00 N
F2WINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F2 EWALL NEA 90.00 90.00 E
F2WINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 NWALL N1A 0.00 90.00 N
F2WINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 NWALL N2A 0.00 90.00 N
F2WINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 SWALL S1A 180.00 90.00 S
F2WINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 SWALL S2A 180.00 90.00 S
F2WINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F2 WWALL C 270.00 90.00 W
F2WINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F2 EWALL C 90.00 90.00 E
F3WINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F3 WWALL SWA 270.00 90.00 W
F3WINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 SWALL SWA 180.00 90.00 S
F3WINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 NWALL NWA 0.00 90.00 N
F3WINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F3 WWALL NWA 270.00 90.00 W
F3WINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F3 EWALL SEA 90.00 90.00 E
F3WINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 SWALL SEA 180.00 90.00 S
F3WINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 NWALL NEA 0.00 90.00 N
F3WINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F3 EWALL NEA 90.00 90.00 E
F3WINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 NWALL N1A 0.00 90.00 N
F3WINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 NWALL N2A 0.00 90.00 N
F3WINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 SWALL S1A 180.00 90.00 S
F3WINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 SWALL S2A 180.00 90.00 S
F3WINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F3 WWALL C 270.00 90.00 W
F3WINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F3 EWALL C 90.00 90.00 E
F4WINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F4 WWALL SWA 270.00 90.00 W
F4WINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 SWALL SWA 180.00 90.00 S
F4WINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 NWALL NWA 0.00 90.00 N
F4WINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F4 WWALL NWA 270.00 90.00 W
F4WINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F4 EWALL SEA 90.00 90.00 E
F4WINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 SWALL SEA 180.00 90.00 S
F4WINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 NWALL NEA 0.00 90.00 N
F4WINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F4 EWALL NEA 90.00 90.00 E
F4WINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 NWALL N1A 0.00 90.00 N
F4WINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 NWALL N2A 0.00 90.00 N
F4WINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 SWALL S1A 180.00 90.00 S
F4WINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 SWALL S2A 180.00 90.00 S
F4WINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F4 WWALL C 270.00 90.00 W
F4WINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F4 EWALL C 90.00 90.00 E
MWINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No M WWALL SWA 270.00 90.00 W
MWINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M SWALL SWA 180.00 90.00 S
MWINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M NWALL NWA 0.00 90.00 N
MWINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No M WWALL NWA 270.00 90.00 W
MWINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No M EWALL SEA 90.00 90.00 E
MWINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M SWALL SEA 180.00 90.00 S
MWINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M NWALL NEA 0.00 90.00 N
MWINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No M EWALL NEA 90.00 90.00 E
MWINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M NWALL N1A 0.00 90.00 N
MWINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M NWALL N2A 0.00 90.00 N
MWINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M SWALL S1A 180.00 90.00 S
MWINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M SWALL S2A 180.00 90.00 S
MWINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No M WWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No M EWALL C 90.00 90.00 E
F6WINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F6 WWALL SWA 270.00 90.00 W
F6WINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 SWALL SWA 180.00 90.00 S
F6WINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 NWALL NWA 0.00 90.00 N
F6WINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F6 WWALL NWA 270.00 90.00 W
F6WINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F6 EWALL SEA 90.00 90.00 E
F6WINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 SWALL SEA 180.00 90.00 S
F6WINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 NWALL NEA 0.00 90.00 N
F6WINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F6 EWALL NEA 90.00 90.00 E
F6WINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 NWALL N1A 0.00 90.00 N
F6WINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 NWALL N2A 0.00 90.00 N
F6WINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 SWALL S1A 180.00 90.00 S
F6WINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 SWALL S2A 180.00 90.00 S
F6WINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F6 WWALL C 270.00 90.00 W
F6WINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F6 EWALL C 90.00 90.00 E
F7WINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F7 WWALL SWA 270.00 90.00 W
F7WINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 SWALL SWA 180.00 90.00 S
F7WINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 NWALL NWA 0.00 90.00 N
F7WINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F7 WWALL NWA 270.00 90.00 W
F7WINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F7 EWALL SEA 90.00 90.00 E
F7WINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 SWALL SEA 180.00 90.00 S
F7WINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 NWALL NEA 0.00 90.00 N
F7WINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F7 EWALL NEA 90.00 90.00 E
F7WINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 NWALL N1A 0.00 90.00 N
F7WINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 NWALL N2A 0.00 90.00 N
F7WINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 SWALL S1A 180.00 90.00 S
F7WINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 SWALL S2A 180.00 90.00 S
F7WINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F7 WWALL C 270.00 90.00 W
F7WINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F7 EWALL C 90.00 90.00 E
F8WINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F8 WWALL SWA 270.00 90.00 W
F8WINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 SWALL SWA 180.00 90.00 S
F8WINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 NWALL NWA 0.00 90.00 N
F8WINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F8 WWALL NWA 270.00 90.00 W
F8WINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F8 EWALL SEA 90.00 90.00 E
F8WINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 SWALL SEA 180.00 90.00 S
F8WINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 NWALL NEA 0.00 90.00 N
F8WINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F8 EWALL NEA 90.00 90.00 E
F8WINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 NWALL N1A 0.00 90.00 N
F8WINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 NWALL N2A 0.00 90.00 N
F8WINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 SWALL S1A 180.00 90.00 S
F8WINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 SWALL S2A 180.00 90.00 S
F8WINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F8 WWALL C 270.00 90.00 W
F8WINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F8 EWALL C 90.00 90.00 E
F9WINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F9 WWALL SWA 270.00 90.00 W
F9WINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 SWALL SWA 180.00 90.00 S
F9WINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 NWALL NWA 0.00 90.00 N
F9WINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F9 WWALL NWA 270.00 90.00 W
F9WINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F9 EWALL SEA 90.00 90.00 E
F9WINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 SWALL SEA 180.00 90.00 S
F9WINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 NWALL NEA 0.00 90.00 N
F9WINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F9 EWALL NEA 90.00 90.00 E
F9WINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 NWALL N1A 0.00 90.00 N
F9WINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 NWALL N2A 0.00 90.00 N
F9WINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 SWALL S1A 180.00 90.00 S
F9WINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 SWALL S2A 180.00 90.00 S
F9WINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F9 WWALL C 270.00 90.00 W
F9WINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F9 EWALL C 90.00 90.00 E
TWINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No T WWALL SWA 270.00 90.00 W
TWINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T SWALL SWA 180.00 90.00 S
TWINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T NWALL NWA 0.00 90.00 N
TWINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No T WWALL NWA 270.00 90.00 W
TWINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No T EWALL SEA 90.00 90.00 E
TWINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T SWALL SEA 180.00 90.00 S
TWINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T NWALL NEA 0.00 90.00 N
TWINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No T EWALL NEA 90.00 90.00 E
TWINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T NWALL N1A 0.00 90.00 N
TWINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T NWALL N2A 0.00 90.00 N
TWINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T SWALL S1A 180.00 90.00 S
TWINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T SWALL S2A 180.00 90.00 S
TWINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No T WWALL C 270.00 90.00 W
TWINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No T EWALL C 90.00 90.00 E
Total or Average           1150.39 4.600 0.293 0.130              
North Total or Average           423.59 4.600 0.293 0.130              
Non-North Total or Average           726.80 4.600 0.293 0.130              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW3 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
GWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW4 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
GWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
GWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW5 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
GWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW9 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
GWINDOW10 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
GWINDOW11 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
GWINDOW12 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
GWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW3 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F2WINDOW4 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F2WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW1 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F2WINDOW5 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F2WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW9 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F2WINDOW10 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F2WINDOW11 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F2WINDOW12 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F2WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW3 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F3WINDOW4 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F3WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW1 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F3WINDOW5 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F3WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW9 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F3WINDOW10 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F3WINDOW11 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F3WINDOW12 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F3WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW3 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F4WINDOW4 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F4WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW1 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F4WINDOW5 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F4WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW9 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F4WINDOW10 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F4WINDOW11 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F4WINDOW12 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F4WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW3 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
MWINDOW4 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
MWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
MWINDOW5 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
MWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW9 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
MWINDOW10 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
MWINDOW11 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
MWINDOW12 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
MWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW3 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F6WINDOW4 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F6WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW1 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F6WINDOW5 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F6WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW9 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F6WINDOW10 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F6WINDOW11 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F6WINDOW12 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F6WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW3 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F7WINDOW4 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F7WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW1 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F7WINDOW5 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F7WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW9 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F7WINDOW10 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F7WINDOW11 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F7WINDOW12 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F7WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW3 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F8WINDOW4 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F8WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW1 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F8WINDOW5 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F8WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW9 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F8WINDOW10 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F8WINDOW11 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F8WINDOW12 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F8WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW3 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F9WINDOW4 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F9WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW1 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F9WINDOW5 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F9WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW9 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F9WINDOW10 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
F9WINDOW11 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F9WINDOW12 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
F9WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW3 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
TWINDOW4 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
TWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
TWINDOW5 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
TWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW9 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
TWINDOW10 0.00 0.00 0.00 1.00 0.00 1.00 0.00 0.00 0.00
TWINDOW11 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
TWINDOW12 1.00 1.00 1.00 0.00 1.00 0.00 1.00 1.00 1.00
TWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
G SW APARTMENT_LIGHTS_HARDWIRED G SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
G NW APARTMENT_LIGHTS_HARDWIRED G NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
OFFICE_LIGHTS_HARDWIRED OFFICE 11.9479 88.25 1054.39 GeneralLights LTG_OFF_SCH 56.26 168.00 55.46 0.0000 Y 10.98
G NE APARTMENT_LIGHTS_HARDWIRED G NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
G N1 APARTMENT_LIGHTS_HARDWIRED G N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
G N2 APARTMENT_LIGHTS_HARDWIRED G N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
G S1 APARTMENT_LIGHTS_HARDWIRED G S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
G S2 APARTMENT_LIGHTS_HARDWIRED G S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
G CORRIDOR_LIGHTS_HARDWIRED G CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F2 SW APARTMENT_LIGHTS_HARDWIRED F2 SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 NW APARTMENT_LIGHTS_HARDWIRED F2 NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 SE APARTMENT_LIGHTS_HARDWIRED F2 SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 NE APARTMENT_LIGHTS_HARDWIRED F2 NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 N1 APARTMENT_LIGHTS_HARDWIRED F2 N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 N2 APARTMENT_LIGHTS_HARDWIRED F2 N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 S1 APARTMENT_LIGHTS_HARDWIRED F2 S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 S2 APARTMENT_LIGHTS_HARDWIRED F2 S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F2 CORRIDOR_LIGHTS_HARDWIRED F2 CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F3 SW APARTMENT_LIGHTS_HARDWIRED F3 SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 NW APARTMENT_LIGHTS_HARDWIRED F3 NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 SE APARTMENT_LIGHTS_HARDWIRED F3 SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 NE APARTMENT_LIGHTS_HARDWIRED F3 NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 N1 APARTMENT_LIGHTS_HARDWIRED F3 N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 N2 APARTMENT_LIGHTS_HARDWIRED F3 N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 S1 APARTMENT_LIGHTS_HARDWIRED F3 S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 S2 APARTMENT_LIGHTS_HARDWIRED F3 S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F3 CORRIDOR_LIGHTS_HARDWIRED F3 CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F4 SW APARTMENT_LIGHTS_HARDWIRED F4 SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 NW APARTMENT_LIGHTS_HARDWIRED F4 NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 SE APARTMENT_LIGHTS_HARDWIRED F4 SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 NE APARTMENT_LIGHTS_HARDWIRED F4 NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 N1 APARTMENT_LIGHTS_HARDWIRED F4 N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 N2 APARTMENT_LIGHTS_HARDWIRED F4 N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 S1 APARTMENT_LIGHTS_HARDWIRED F4 S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 S2 APARTMENT_LIGHTS_HARDWIRED F4 S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F4 CORRIDOR_LIGHTS_HARDWIRED F4 CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
M SW APARTMENT_LIGHTS_HARDWIRED M SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M NW APARTMENT_LIGHTS_HARDWIRED M NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M SE APARTMENT_LIGHTS_HARDWIRED M SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M NE APARTMENT_LIGHTS_HARDWIRED M NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M N1 APARTMENT_LIGHTS_HARDWIRED M N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M N2 APARTMENT_LIGHTS_HARDWIRED M N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M S1 APARTMENT_LIGHTS_HARDWIRED M S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M S2 APARTMENT_LIGHTS_HARDWIRED M S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
M CORRIDOR_LIGHTS_HARDWIRED M CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F6 SW APARTMENT_LIGHTS_HARDWIRED F6 SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 NW APARTMENT_LIGHTS_HARDWIRED F6 NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 SE APARTMENT_LIGHTS_HARDWIRED F6 SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 NE APARTMENT_LIGHTS_HARDWIRED F6 NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 N1 APARTMENT_LIGHTS_HARDWIRED F6 N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 N2 APARTMENT_LIGHTS_HARDWIRED F6 N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 S1 APARTMENT_LIGHTS_HARDWIRED F6 S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 S2 APARTMENT_LIGHTS_HARDWIRED F6 S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F6 CORRIDOR_LIGHTS_HARDWIRED F6 CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F7 SW APARTMENT_LIGHTS_HARDWIRED F7 SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 NW APARTMENT_LIGHTS_HARDWIRED F7 NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 SE APARTMENT_LIGHTS_HARDWIRED F7 SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 NE APARTMENT_LIGHTS_HARDWIRED F7 NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 N1 APARTMENT_LIGHTS_HARDWIRED F7 N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 N2 APARTMENT_LIGHTS_HARDWIRED F7 N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 S1 APARTMENT_LIGHTS_HARDWIRED F7 S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 S2 APARTMENT_LIGHTS_HARDWIRED F7 S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F7 CORRIDOR_LIGHTS_HARDWIRED F7 CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F8 SW APARTMENT_LIGHTS_HARDWIRED F8 SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 NW APARTMENT_LIGHTS_HARDWIRED F8 NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 SE APARTMENT_LIGHTS_HARDWIRED F8 SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 NE APARTMENT_LIGHTS_HARDWIRED F8 NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 N1 APARTMENT_LIGHTS_HARDWIRED F8 N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 N2 APARTMENT_LIGHTS_HARDWIRED F8 N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 S1 APARTMENT_LIGHTS_HARDWIRED F8 S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 S2 APARTMENT_LIGHTS_HARDWIRED F8 S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F8 CORRIDOR_LIGHTS_HARDWIRED F8 CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F9 SW APARTMENT_LIGHTS_HARDWIRED F9 SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 NW APARTMENT_LIGHTS_HARDWIRED F9 NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 SE APARTMENT_LIGHTS_HARDWIRED F9 SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 NE APARTMENT_LIGHTS_HARDWIRED F9 NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 N1 APARTMENT_LIGHTS_HARDWIRED F9 N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 N2 APARTMENT_LIGHTS_HARDWIRED F9 N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 S1 APARTMENT_LIGHTS_HARDWIRED F9 S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 S2 APARTMENT_LIGHTS_HARDWIRED F9 S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
F9 CORRIDOR_LIGHTS_HARDWIRED F9 CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
T SW APARTMENT_LIGHTS_HARDWIRED T SW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T NW APARTMENT_LIGHTS_HARDWIRED T NW APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T SE APARTMENT_LIGHTS_HARDWIRED T SE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T NE APARTMENT_LIGHTS_HARDWIRED T NE APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T N1 APARTMENT_LIGHTS_HARDWIRED T N1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T N2 APARTMENT_LIGHTS_HARDWIRED T N2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T S1 APARTMENT_LIGHTS_HARDWIRED T S1 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T S2 APARTMENT_LIGHTS_HARDWIRED T S2 APARTMENT 11.5174 88.25 1016.39 GeneralLights LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 1.93
T CORRIDOR_LIGHTS_HARDWIRED T CORRIDOR 8.5250 77.66 662.04 GeneralLights LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
G SW APARTMENT_LIGHTS_PLUGIN G SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
G NW APARTMENT_LIGHTS_PLUGIN G NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
OFFICE_LIGHTS_PLUGIN OFFICE 11.9479 88.25 1054.39 GeneralLights-plugin LTG_OFF_SCH 56.26 168.00 55.46 0.0000 Y 10.98
G NE APARTMENT_LIGHTS_PLUGIN G NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
G N1 APARTMENT_LIGHTS_PLUGIN G N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
G N2 APARTMENT_LIGHTS_PLUGIN G N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
G S1 APARTMENT_LIGHTS_PLUGIN G S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
G S2 APARTMENT_LIGHTS_PLUGIN G S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 SW APARTMENT_LIGHTS_PLUGIN F2 SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 NW APARTMENT_LIGHTS_PLUGIN F2 NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 SE APARTMENT_LIGHTS_PLUGIN F2 SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 NE APARTMENT_LIGHTS_PLUGIN F2 NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 N1 APARTMENT_LIGHTS_PLUGIN F2 N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 N2 APARTMENT_LIGHTS_PLUGIN F2 N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 S1 APARTMENT_LIGHTS_PLUGIN F2 S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F2 S2 APARTMENT_LIGHTS_PLUGIN F2 S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 SW APARTMENT_LIGHTS_PLUGIN F3 SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 NW APARTMENT_LIGHTS_PLUGIN F3 NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 SE APARTMENT_LIGHTS_PLUGIN F3 SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 NE APARTMENT_LIGHTS_PLUGIN F3 NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 N1 APARTMENT_LIGHTS_PLUGIN F3 N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 N2 APARTMENT_LIGHTS_PLUGIN F3 N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 S1 APARTMENT_LIGHTS_PLUGIN F3 S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F3 S2 APARTMENT_LIGHTS_PLUGIN F3 S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 SW APARTMENT_LIGHTS_PLUGIN F4 SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 NW APARTMENT_LIGHTS_PLUGIN F4 NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 SE APARTMENT_LIGHTS_PLUGIN F4 SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 NE APARTMENT_LIGHTS_PLUGIN F4 NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 N1 APARTMENT_LIGHTS_PLUGIN F4 N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 N2 APARTMENT_LIGHTS_PLUGIN F4 N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 S1 APARTMENT_LIGHTS_PLUGIN F4 S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F4 S2 APARTMENT_LIGHTS_PLUGIN F4 S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M SW APARTMENT_LIGHTS_PLUGIN M SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M NW APARTMENT_LIGHTS_PLUGIN M NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M SE APARTMENT_LIGHTS_PLUGIN M SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M NE APARTMENT_LIGHTS_PLUGIN M NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M N1 APARTMENT_LIGHTS_PLUGIN M N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M N2 APARTMENT_LIGHTS_PLUGIN M N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M S1 APARTMENT_LIGHTS_PLUGIN M S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M S2 APARTMENT_LIGHTS_PLUGIN M S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
M CORRIDOR_LIGHTS_PLUGIN M CORRIDOR 8.5250 77.66 662.04 GeneralLights-plugin LTG_COR_SCH 149.10 168.00 149.10 0.0000 N 18.53
F6 SW APARTMENT_LIGHTS_PLUGIN F6 SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F6 NW APARTMENT_LIGHTS_PLUGIN F6 NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F6 SE APARTMENT_LIGHTS_PLUGIN F6 SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F6 NE APARTMENT_LIGHTS_PLUGIN F6 NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F6 N1 APARTMENT_LIGHTS_PLUGIN F6 N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F6 N2 APARTMENT_LIGHTS_PLUGIN F6 N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F6 S1 APARTMENT_LIGHTS_PLUGIN F6 S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F6 S2 APARTMENT_LIGHTS_PLUGIN F6 S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 SW APARTMENT_LIGHTS_PLUGIN F7 SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 NW APARTMENT_LIGHTS_PLUGIN F7 NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 SE APARTMENT_LIGHTS_PLUGIN F7 SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 NE APARTMENT_LIGHTS_PLUGIN F7 NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 N1 APARTMENT_LIGHTS_PLUGIN F7 N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 N2 APARTMENT_LIGHTS_PLUGIN F7 N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 S1 APARTMENT_LIGHTS_PLUGIN F7 S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F7 S2 APARTMENT_LIGHTS_PLUGIN F7 S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 SW APARTMENT_LIGHTS_PLUGIN F8 SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 NW APARTMENT_LIGHTS_PLUGIN F8 NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 SE APARTMENT_LIGHTS_PLUGIN F8 SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 NE APARTMENT_LIGHTS_PLUGIN F8 NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 N1 APARTMENT_LIGHTS_PLUGIN F8 N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 N2 APARTMENT_LIGHTS_PLUGIN F8 N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 S1 APARTMENT_LIGHTS_PLUGIN F8 S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F8 S2 APARTMENT_LIGHTS_PLUGIN F8 S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 SW APARTMENT_LIGHTS_PLUGIN F9 SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 NW APARTMENT_LIGHTS_PLUGIN F9 NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 SE APARTMENT_LIGHTS_PLUGIN F9 SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 NE APARTMENT_LIGHTS_PLUGIN F9 NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 N1 APARTMENT_LIGHTS_PLUGIN F9 N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 N2 APARTMENT_LIGHTS_PLUGIN F9 N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 S1 APARTMENT_LIGHTS_PLUGIN F9 S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
F9 S2 APARTMENT_LIGHTS_PLUGIN F9 S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T SW APARTMENT_LIGHTS_PLUGIN T SW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T NW APARTMENT_LIGHTS_PLUGIN T NW APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T SE APARTMENT_LIGHTS_PLUGIN T SE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T NE APARTMENT_LIGHTS_PLUGIN T NE APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T N1 APARTMENT_LIGHTS_PLUGIN T N1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T N2 APARTMENT_LIGHTS_PLUGIN T N2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T S1 APARTMENT_LIGHTS_PLUGIN T S1 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
T S2 APARTMENT_LIGHTS_PLUGIN T S2 APARTMENT 2.9063 88.25 256.47 GeneralLights-plugin LTG_APT_SCH 10.10 168.00 10.10 0.0000 Y 0.49
Interior Lighting Total   7.3426 14974.03 109947.72               416.41


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 10720.10 AstronomicalClock -   83.69 83.69 168.41
Exterior Lighting Total 10720.10           168.41



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
CENTRAL BOILER Boiler:HotWater 328744.51 0.80    
CENTRAL TOWER EvaporativeFluidCooler:SingleSpeed 262995.61      


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
HEAT PUMP COOLING MODE AIRLOOP G SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4563.88 3111.56 1452.33 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4297.11 2908.93 1388.18 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP OFFICE Coil:Cooling:WaterToAirHeatPump:EquationFit   5878.40 3986.43 1891.97 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3688.42 2452.89 1235.53 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2416.46 1504.00 912.46 0.62 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2399.94 1491.91 908.03 0.62 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3038.39 1958.97 1079.42 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3106.59 2010.88 1095.71 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5208.47 3584.96 1623.51 0.69 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4908.76 3355.31 1553.45 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4924.55 3372.44 1552.12 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4234.91 2848.98 1385.93 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2832.21 1802.02 1030.19 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2819.34 1792.46 1026.88 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3485.83 2286.54 1199.30 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3510.09 2305.09 1205.01 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5229.11 3585.55 1643.55 0.69 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4941.72 3365.77 1575.96 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4742.64 3217.40 1525.25 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4285.20 2873.52 1411.68 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2877.69 1829.59 1048.10 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2864.95 1820.13 1044.81 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3519.71 2304.62 1215.09 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3530.77 2313.08 1217.69 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5250.32 3590.49 1659.83 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4967.87 3374.76 1593.10 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4744.89 3208.19 1536.70 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4314.05 2885.18 1428.88 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2909.18 1848.29 1060.90 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2896.54 1838.92 1057.62 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3540.03 2314.30 1225.74 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3549.13 2321.25 1227.88 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5299.91 3619.41 1680.50 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5022.30 3407.56 1614.75 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4794.68 3237.54 1557.14 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4370.47 2919.86 1450.62 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2967.41 1887.74 1079.67 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2954.87 1878.45 1076.42 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3587.83 2345.92 1241.90 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3596.63 2352.65 1243.98 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5260.45 3581.16 1679.29 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4984.97 3371.24 1613.72 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4758.17 3202.05 1556.12 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4336.22 2886.55 1449.68 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2934.90 1860.27 1074.63 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2922.48 1851.10 1071.37 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3548.68 2312.17 1236.51 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3557.43 2318.85 1238.58 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5251.79 3567.63 1684.16 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4979.44 3360.34 1619.11 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4752.39 3191.09 1561.30 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4333.24 2878.05 1455.19 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2933.17 1856.14 1077.03 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2920.85 1847.06 1073.78 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3540.03 2302.12 1237.91 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3548.77 2308.79 1239.98 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5262.02 3569.34 1692.68 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4992.36 3364.27 1628.09 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4764.71 3194.69 1570.03 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4353.82 2887.02 1466.80 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2949.97 1866.04 1083.93 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2937.77 1857.06 1080.71 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3549.61 2306.27 1243.34 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3558.35 2312.93 1245.42 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5379.36 3653.76 1725.60 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5112.77 3450.96 1661.81 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4832.22 3240.89 1591.34 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4416.77 2929.78 1486.99 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3066.27 1949.83 1116.43 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3054.17 1940.90 1113.27 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3629.65 2363.94 1265.71 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3639.31 2371.30 1268.01 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SW Coil:Cooling:WaterToAirHeatPump:EquationFit   6227.30 4299.89 1927.40 0.69 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5903.58 4052.75 1850.84 0.69 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SE Coil:Cooling:WaterToAirHeatPump:EquationFit   5551.15 3785.31 1765.83 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NE Coil:Cooling:WaterToAirHeatPump:EquationFit   5022.58 3384.49 1638.09 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3746.82 2449.66 1297.16 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3747.64 2450.39 1297.25 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   4494.04 3020.53 1473.51 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   4504.97 3028.97 1475.99 0.67 0.00    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
None            


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
HEAT PUMP HEATING MODE AIRLOOP G SW Coil:Heating:WaterToAirHeatPump:EquationFit   4563.88 0.00
HEAT PUMP HEATING MODE AIRLOOP G NW Coil:Heating:WaterToAirHeatPump:EquationFit   4297.11 0.00
HEAT PUMP HEATING MODE AIRLOOP OFFICE Coil:Heating:WaterToAirHeatPump:EquationFit   5878.40 0.00
HEAT PUMP HEATING MODE AIRLOOP G NE Coil:Heating:WaterToAirHeatPump:EquationFit   3688.42 0.00
HEAT PUMP HEATING MODE AIRLOOP G N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2416.46 0.00
HEAT PUMP HEATING MODE AIRLOOP G N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2399.94 0.00
HEAT PUMP HEATING MODE AIRLOOP G S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3038.39 0.00
HEAT PUMP HEATING MODE AIRLOOP G S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3106.59 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5208.47 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4908.76 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4924.55 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4234.91 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2832.21 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2819.34 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3485.83 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3510.09 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5229.11 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4941.72 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4742.64 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4285.20 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2877.69 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2864.95 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3519.71 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3530.77 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5250.32 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4967.87 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4744.89 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4314.05 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2909.18 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2896.54 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3540.03 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3549.13 0.00
HEAT PUMP HEATING MODE AIRLOOP M SW Coil:Heating:WaterToAirHeatPump:EquationFit   5299.91 0.00
HEAT PUMP HEATING MODE AIRLOOP M NW Coil:Heating:WaterToAirHeatPump:EquationFit   5022.30 0.00
HEAT PUMP HEATING MODE AIRLOOP M SE Coil:Heating:WaterToAirHeatPump:EquationFit   4794.68 0.00
HEAT PUMP HEATING MODE AIRLOOP M NE Coil:Heating:WaterToAirHeatPump:EquationFit   4370.47 0.00
HEAT PUMP HEATING MODE AIRLOOP M N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2967.41 0.00
HEAT PUMP HEATING MODE AIRLOOP M N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2954.87 0.00
HEAT PUMP HEATING MODE AIRLOOP M S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3587.83 0.00
HEAT PUMP HEATING MODE AIRLOOP M S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3596.63 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5260.45 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4984.97 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4758.17 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4336.22 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2934.90 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2922.48 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3548.68 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3557.43 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5251.79 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4979.44 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4752.39 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4333.24 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2933.17 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2920.85 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3540.03 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3548.77 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5262.02 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4992.36 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4764.71 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4353.82 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2949.97 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2937.77 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3549.61 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3558.35 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5379.36 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NW Coil:Heating:WaterToAirHeatPump:EquationFit   5112.77 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4832.22 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4416.77 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3066.27 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3054.17 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3629.65 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3639.31 0.00
HEAT PUMP HEATING MODE AIRLOOP T SW Coil:Heating:WaterToAirHeatPump:EquationFit   6227.30 0.00
HEAT PUMP HEATING MODE AIRLOOP T NW Coil:Heating:WaterToAirHeatPump:EquationFit   5903.58 0.00
HEAT PUMP HEATING MODE AIRLOOP T SE Coil:Heating:WaterToAirHeatPump:EquationFit   5551.15 0.00
HEAT PUMP HEATING MODE AIRLOOP T NE Coil:Heating:WaterToAirHeatPump:EquationFit   5022.58 0.00
HEAT PUMP HEATING MODE AIRLOOP T N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3746.82 0.00
HEAT PUMP HEATING MODE AIRLOOP T N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3747.64 0.00
HEAT PUMP HEATING MODE AIRLOOP T S1 Coil:Heating:WaterToAirHeatPump:EquationFit   4494.04 0.00
HEAT PUMP HEATING MODE AIRLOOP T S2 Coil:Heating:WaterToAirHeatPump:EquationFit   4504.97 0.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW Coil:Heating:Electric   1705.49 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW Coil:Heating:Electric   1700.37 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE Coil:Heating:Electric   2346.75 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE Coil:Heating:Electric   1700.37 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 Coil:Heating:Electric   1197.34 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 Coil:Heating:Electric   1197.34 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 Coil:Heating:Electric   1200.38 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 Coil:Heating:Electric   1208.79 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW Coil:Heating:Electric   1642.13 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW Coil:Heating:Electric   1637.22 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE Coil:Heating:Electric   1668.43 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE Coil:Heating:Electric   1637.22 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW Coil:Heating:Electric   1618.17 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW Coil:Heating:Electric   1614.57 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE Coil:Heating:Electric   1621.51 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE Coil:Heating:Electric   1614.57 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW Coil:Heating:Electric   1627.15 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW Coil:Heating:Electric   1625.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE Coil:Heating:Electric   1627.56 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE Coil:Heating:Electric   1625.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW Coil:Heating:Electric   1619.95 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW Coil:Heating:Electric   1618.36 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE Coil:Heating:Electric   1620.00 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE Coil:Heating:Electric   1618.36 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW Coil:Heating:Electric   1677.05 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW Coil:Heating:Electric   1677.50 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE Coil:Heating:Electric   1677.06 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE Coil:Heating:Electric   1677.50 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW Coil:Heating:Electric   1711.56 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW Coil:Heating:Electric   1712.79 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE Coil:Heating:Electric   1711.56 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE Coil:Heating:Electric   1712.79 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW Coil:Heating:Electric   1747.21 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW Coil:Heating:Electric   1749.00 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE Coil:Heating:Electric   1747.21 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE Coil:Heating:Electric   1749.00 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 Coil:Heating:Electric   1110.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW Coil:Heating:Electric   1858.38 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW Coil:Heating:Electric   1859.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE Coil:Heating:Electric   1858.38 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE Coil:Heating:Electric   1859.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 Coil:Heating:Electric   1186.34 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 Coil:Heating:Electric   1186.34 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 Coil:Heating:Electric   1185.33 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 Coil:Heating:Electric   1185.33 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW Coil:Heating:Electric   2230.96 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW Coil:Heating:Electric   2236.06 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE Coil:Heating:Electric   2230.96 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE Coil:Heating:Electric   2236.06 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 Coil:Heating:Electric   1590.70 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 Coil:Heating:Electric   1590.70 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 Coil:Heating:Electric   1584.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 Coil:Heating:Electric   1584.65 1.00


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
AIRLOOP G SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.25 281.37 1120.11 1.00 General
AIRLOOP G NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.23 261.45 1120.11 1.00 General
AIRLOOP OFFICE SUPPLY FAN Fan:OnOff 0.56 622.50 0.32 358.83 1120.11 1.00 General
AIRLOOP G NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 216.80 1120.11 1.00 General
AIRLOOP G N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.11 120.58 1120.11 1.00 General
AIRLOOP G N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.11 119.35 1120.11 1.00 General
AIRLOOP G S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.15 164.90 1120.11 1.00 General
AIRLOOP G S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.15 170.20 1120.11 1.00 General
AIRLOOP F2 SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.29 328.07 1120.11 1.00 General
AIRLOOP F2 NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 305.19 1120.11 1.00 General
AIRLOOP F2 SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 307.54 1120.11 1.00 General
AIRLOOP F2 NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.23 255.53 1120.11 1.00 General
AIRLOOP F2 N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.13 149.79 1120.11 1.00 General
AIRLOOP F2 N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.13 148.82 1120.11 1.00 General
AIRLOOP F2 S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 197.13 1120.11 1.00 General
AIRLOOP F2 S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 199.02 1120.11 1.00 General
AIRLOOP F3 SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.29 327.07 1120.11 1.00 General
AIRLOOP F3 NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 305.20 1120.11 1.00 General
AIRLOOP F3 SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 290.67 1120.11 1.00 General
AIRLOOP F3 NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.23 256.98 1120.11 1.00 General
AIRLOOP F3 N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 151.98 1120.11 1.00 General
AIRLOOP F3 N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.13 151.02 1120.11 1.00 General
AIRLOOP F3 S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 198.35 1120.11 1.00 General
AIRLOOP F3 S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 199.21 1120.11 1.00 General
AIRLOOP F4 SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.29 326.77 1120.11 1.00 General
AIRLOOP F4 NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 305.32 1120.11 1.00 General
AIRLOOP F4 SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 288.93 1120.11 1.00 General
AIRLOOP F4 NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.23 257.37 1120.11 1.00 General
AIRLOOP F4 N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 153.42 1120.11 1.00 General
AIRLOOP F4 N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 152.47 1120.11 1.00 General
AIRLOOP F4 S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 198.86 1120.11 1.00 General
AIRLOOP F4 S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 199.57 1120.11 1.00 General
AIRLOOP M SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.29 329.06 1120.11 1.00 General
AIRLOOP M NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 308.01 1120.11 1.00 General
AIRLOOP M SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 291.27 1120.11 1.00 General
AIRLOOP M NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.23 260.26 1120.11 1.00 General
AIRLOOP M N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 157.06 1120.11 1.00 General
AIRLOOP M N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 156.11 1120.11 1.00 General
AIRLOOP M S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 201.70 1120.11 1.00 General
AIRLOOP M S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 202.38 1120.11 1.00 General
AIRLOOP F6 SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.29 324.61 1120.11 1.00 General
AIRLOOP F6 NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 303.75 1120.11 1.00 General
AIRLOOP F6 SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 287.10 1120.11 1.00 General
AIRLOOP F6 NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.23 256.29 1120.11 1.00 General
AIRLOOP F6 N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 153.93 1120.11 1.00 General
AIRLOOP F6 N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 153.00 1120.11 1.00 General
AIRLOOP F6 S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 197.93 1120.11 1.00 General
AIRLOOP F6 S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 198.61 1120.11 1.00 General
AIRLOOP F7 SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.29 322.73 1120.11 1.00 General
AIRLOOP F7 NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 302.14 1120.11 1.00 General
AIRLOOP F7 SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.25 285.49 1120.11 1.00 General
AIRLOOP F7 NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.23 254.93 1120.11 1.00 General
AIRLOOP F7 N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 153.23 1120.11 1.00 General
AIRLOOP F7 N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 152.31 1120.11 1.00 General
AIRLOOP F7 S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 196.61 1120.11 1.00 General
AIRLOOP F7 S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 197.29 1120.11 1.00 General
AIRLOOP F8 SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.29 322.46 1120.11 1.00 General
AIRLOOP F8 NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 302.10 1120.11 1.00 General
AIRLOOP F8 SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.25 285.41 1120.11 1.00 General
AIRLOOP F8 NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.23 255.09 1120.11 1.00 General
AIRLOOP F8 N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 153.98 1120.11 1.00 General
AIRLOOP F8 N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 153.07 1120.11 1.00 General
AIRLOOP F8 S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 196.77 1120.11 1.00 General
AIRLOOP F8 S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 197.45 1120.11 1.00 General
AIRLOOP F9 SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.30 330.65 1120.11 1.00 General
AIRLOOP F9 NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.28 310.52 1120.11 1.00 General
AIRLOOP F9 SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.26 289.71 1120.11 1.00 General
AIRLOOP F9 NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.23 259.04 1120.11 1.00 General
AIRLOOP F9 N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 162.26 1120.11 1.00 General
AIRLOOP F9 N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.14 161.35 1120.11 1.00 General
AIRLOOP F9 S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 202.39 1120.11 1.00 General
AIRLOOP F9 S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.18 203.14 1120.11 1.00 General
AIRLOOP T SW SUPPLY FAN Fan:OnOff 0.56 622.50 0.35 395.74 1120.11 1.00 General
AIRLOOP T NW SUPPLY FAN Fan:OnOff 0.56 622.50 0.33 371.13 1120.11 1.00 General
AIRLOOP T SE SUPPLY FAN Fan:OnOff 0.56 622.50 0.31 344.54 1120.11 1.00 General
AIRLOOP T NE SUPPLY FAN Fan:OnOff 0.56 622.50 0.27 304.59 1120.11 1.00 General
AIRLOOP T N1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 210.79 1120.11 1.00 General
AIRLOOP T N2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.19 210.87 1120.11 1.00 General
AIRLOOP T S1 SUPPLY FAN Fan:OnOff 0.56 622.50 0.24 269.00 1120.11 1.00 General
AIRLOOP T S2 SUPPLY FAN Fan:OnOff 0.56 622.50 0.24 269.87 1120.11 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
SHWSYS1 PUMP Pump:ConstantSpeed Intermittent 29891.00 0.0003 36.93 127739.32 0.30
PLANT CIRC PUMP Pump:ConstantSpeed Intermittent 179045.11 0.0072 1823.72 255050.01 0.90


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
SHWSYS1 WATER HEATER WaterHeater:Mixed 2.27 175842.64 0.80 0.00 0.00



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 2670.80 3204.96 0.209 0.251 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 16:15:00 33.27 0.01651
G NW APARTMENT 2481.67 2978.00 0.195 0.233 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 17:15:00 32.60 0.01651
OFFICE 3406.07 4087.29 0.267 0.320 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 11:00:00 32.08 0.01651
G NE APARTMENT 2057.81 2469.37 0.161 0.194 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 10:15:00 31.19 0.01651
G N1 APARTMENT 1144.59 1373.51 0.090 0.108 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 31.41 0.01651
G N2 APARTMENT 1132.93 1359.51 0.089 0.107 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 31.41 0.01651
G S1 APARTMENT 1565.27 1878.33 0.123 0.147 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 33.70 0.01651
G S2 APARTMENT 1615.54 1938.65 0.127 0.152 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 33.70 0.01651
F2 SW APARTMENT 3113.95 3736.74 0.244 0.293 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 16:30:00 33.11 0.01651
F2 NW APARTMENT 2896.83 3476.20 0.227 0.272 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 17:15:00 32.60 0.01651
F2 SE APARTMENT 2919.14 3502.96 0.229 0.275 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 11:15:00 32.28 0.01651
F2 NE APARTMENT 2425.40 2910.48 0.190 0.228 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 10:15:00 31.19 0.01651
F2 N1 APARTMENT 1421.80 1706.16 0.111 0.134 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:15:00 31.71 0.01651
F2 N2 APARTMENT 1412.59 1695.10 0.111 0.133 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:15:00 31.71 0.01651
F2 S1 APARTMENT 1871.21 2245.45 0.147 0.176 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651
F2 S2 APARTMENT 1889.17 2267.00 0.148 0.178 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651
F3 SW APARTMENT 3104.41 3725.29 0.243 0.292 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 16:30:00 33.11 0.01651
F3 NW APARTMENT 2896.86 3476.23 0.227 0.272 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 17:15:00 32.60 0.01651
F3 SE APARTMENT 2758.93 3310.71 0.216 0.260 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 11:15:00 32.28 0.01651
F3 NE APARTMENT 2439.09 2926.91 0.191 0.229 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 10:15:00 31.19 0.01651
F3 N1 APARTMENT 1442.60 1731.12 0.113 0.136 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:15:00 31.71 0.01651
F3 N2 APARTMENT 1433.50 1720.20 0.112 0.135 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:15:00 31.71 0.01651
F3 S1 APARTMENT 1882.73 2259.28 0.148 0.177 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651
F3 S2 APARTMENT 1890.94 2269.13 0.148 0.178 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651
F4 SW APARTMENT 3101.57 3721.88 0.243 0.292 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 16:30:00 33.11 0.01651
F4 NW APARTMENT 2897.96 3477.55 0.227 0.273 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 17:15:00 32.60 0.01651
F4 SE APARTMENT 2742.42 3290.90 0.215 0.258 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 11:15:00 32.28 0.01651
F4 NE APARTMENT 2442.78 2931.33 0.191 0.230 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 10:15:00 31.19 0.01651
F4 N1 APARTMENT 1456.26 1747.51 0.114 0.137 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:15:00 31.71 0.01651
F4 N2 APARTMENT 1447.25 1736.70 0.113 0.136 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:15:00 31.71 0.01651
F4 S1 APARTMENT 1887.59 2265.11 0.148 0.178 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651
F4 S2 APARTMENT 1894.34 2273.21 0.148 0.178 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651
M SW APARTMENT 3123.29 3747.95 0.245 0.294 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 16:30:00 33.11 0.01651
M NW APARTMENT 2923.45 3508.14 0.229 0.275 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 17:15:00 32.60 0.01651
M SE APARTMENT 2764.59 3317.51 0.217 0.260 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 11:15:00 32.28 0.01651
M NE APARTMENT 2470.16 2964.20 0.194 0.232 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 10:15:00 31.19 0.01651
M N1 APARTMENT 1490.78 1788.93 0.117 0.140 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:15:00 31.71 0.01651
M N2 APARTMENT 1481.84 1778.21 0.116 0.139 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:15:00 31.71 0.01651
M S1 APARTMENT 1914.47 2297.36 0.150 0.180 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651
M S2 APARTMENT 1920.99 2305.19 0.151 0.181 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651
F6 SW APARTMENT 3080.95 3697.14 0.241 0.290 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 16:30:00 33.11 0.01651
F6 NW APARTMENT 2883.00 3459.60 0.226 0.271 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 17:15:00 32.60 0.01651
F6 SE APARTMENT 2724.92 3269.91 0.214 0.256 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 11:15:00 32.28 0.01651
F6 NE APARTMENT 2432.54 2919.05 0.191 0.229 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 10:15:00 31.19 0.01651
F6 N1 APARTMENT 1461.13 1753.36 0.115 0.137 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:15:00 31.71 0.01651
F6 N2 APARTMENT 1452.32 1742.78 0.114 0.137 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:15:00 31.71 0.01651
F6 S1 APARTMENT 1878.69 2254.43 0.147 0.177 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651
F6 S2 APARTMENT 1885.18 2262.21 0.148 0.177 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651
F7 SW APARTMENT 3063.14 3675.77 0.240 0.288 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 16:30:00 33.11 0.01651
F7 NW APARTMENT 2867.75 3441.30 0.225 0.270 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 17:15:00 32.60 0.01651
F7 SE APARTMENT 2709.63 3251.55 0.212 0.255 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 11:15:00 32.28 0.01651
F7 NE APARTMENT 2419.61 2903.53 0.190 0.228 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 10:15:00 31.19 0.01651
F7 N1 APARTMENT 1454.41 1745.29 0.114 0.137 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:15:00 31.71 0.01651
F7 N2 APARTMENT 1445.69 1734.83 0.113 0.136 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:15:00 31.71 0.01651
F7 S1 APARTMENT 1866.21 2239.45 0.146 0.176 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651
F7 S2 APARTMENT 1872.67 2247.21 0.147 0.176 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651
F8 SW APARTMENT 3060.56 3672.67 0.240 0.288 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 16:30:00 33.11 0.01651
F8 NW APARTMENT 2867.33 3440.80 0.225 0.270 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 17:15:00 32.60 0.01651
F8 SE APARTMENT 2708.89 3250.67 0.212 0.255 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 11:15:00 32.28 0.01651
F8 NE APARTMENT 2421.08 2905.29 0.190 0.228 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 10:30:00 31.49 0.01651
F8 N1 APARTMENT 1461.52 1753.83 0.115 0.137 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:15:00 31.71 0.01651
F8 N2 APARTMENT 1452.90 1743.48 0.114 0.137 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:15:00 31.71 0.01651
F8 S1 APARTMENT 1867.72 2241.26 0.146 0.176 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651
F8 S2 APARTMENT 1874.18 2249.01 0.147 0.176 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651
F9 SW APARTMENT 3138.27 3765.92 0.246 0.295 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 16:30:00 33.11 0.01651
F9 NW APARTMENT 2947.24 3536.69 0.231 0.277 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 17:15:00 32.60 0.01651
F9 SE APARTMENT 2749.66 3299.60 0.216 0.259 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 11:15:00 32.28 0.01651
F9 NE APARTMENT 2458.56 2950.28 0.193 0.231 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 10:30:00 31.49 0.01651
F9 N1 APARTMENT 1540.14 1848.17 0.121 0.145 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:15:00 31.71 0.01651
F9 N2 APARTMENT 1531.56 1837.87 0.120 0.144 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 18:15:00 31.71 0.01651
F9 S1 APARTMENT 1921.03 2305.24 0.151 0.181 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651
F9 S2 APARTMENT 1928.17 2313.80 0.151 0.181 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651
T SW APARTMENT 3755.97 4507.16 0.294 0.353 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 16:00:00 33.43 0.01651
T NW APARTMENT 3522.39 4226.87 0.276 0.331 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 16:45:00 32.95 0.01651
T SE APARTMENT 3270.03 3924.04 0.256 0.308 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 11:30:00 32.48 0.01651
T NE APARTMENT 2890.85 3469.01 0.227 0.272 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 10:45:00 31.79 0.01651
T N1 APARTMENT 2000.74 2400.89 0.157 0.188 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 14:45:00 33.90 0.01651
T N2 APARTMENT 2001.53 2401.83 0.157 0.188 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 14:45:00 33.90 0.01651
T S1 APARTMENT 2553.26 3063.91 0.200 0.240 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651
T S2 APARTMENT 2561.47 3073.76 0.201 0.241 TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.80 0.01651


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 988.52 1186.22 0.044 0.053 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 09:15:00 4.60 0.00526
G NW APARTMENT 984.19 1181.03 0.044 0.053 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 09:15:00 4.60 0.00526
OFFICE 1318.38 1582.05 0.059 0.070 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 18:45:00 4.60 0.00526
G NE APARTMENT 984.19 1181.03 0.044 0.053 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 09:15:00 4.60 0.00526
G N1 APARTMENT 558.80 670.56 0.025 0.030 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 09:15:00 4.60 0.00526
G N2 APARTMENT 558.80 670.56 0.025 0.030 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 09:15:00 4.60 0.00526
G S1 APARTMENT 561.37 673.64 0.025 0.030 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 09:15:00 4.60 0.00526
G S2 APARTMENT 568.48 682.17 0.025 0.030 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 09:15:00 4.60 0.00526
F2 SW APARTMENT 934.95 1121.94 0.042 0.050 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F2 NW APARTMENT 930.80 1116.96 0.041 0.050 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F2 SE APARTMENT 957.19 1148.63 0.043 0.051 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F2 NE APARTMENT 930.80 1116.96 0.041 0.050 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F2 N1 APARTMENT 428.19 513.83 0.019 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F2 N2 APARTMENT 428.19 513.83 0.019 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F2 S1 APARTMENT 434.72 521.66 0.019 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F2 S2 APARTMENT 436.35 523.62 0.019 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F3 SW APARTMENT 914.69 1097.63 0.041 0.049 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F3 NW APARTMENT 911.65 1093.98 0.041 0.049 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F3 SE APARTMENT 917.52 1101.02 0.041 0.049 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F3 NE APARTMENT 911.65 1093.98 0.041 0.049 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F3 N1 APARTMENT 395.42 474.51 0.018 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F3 N2 APARTMENT 395.42 474.51 0.018 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F3 S1 APARTMENT 399.00 478.79 0.018 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F3 S2 APARTMENT 399.29 479.15 0.018 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F4 SW APARTMENT 922.29 1106.75 0.041 0.049 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F4 NW APARTMENT 920.70 1104.84 0.041 0.049 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F4 SE APARTMENT 922.64 1107.17 0.041 0.049 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F4 NE APARTMENT 920.70 1104.84 0.041 0.049 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F4 N1 APARTMENT 392.99 471.59 0.018 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F4 N2 APARTMENT 392.99 471.59 0.018 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F4 S1 APARTMENT 394.87 473.84 0.018 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F4 S2 APARTMENT 394.92 473.90 0.018 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
M SW APARTMENT 916.20 1099.44 0.041 0.049 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
M NW APARTMENT 914.86 1097.83 0.041 0.049 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
M SE APARTMENT 916.24 1099.49 0.041 0.049 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
M NE APARTMENT 914.86 1097.83 0.041 0.049 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
M N1 APARTMENT 382.12 458.55 0.017 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
M N2 APARTMENT 382.12 458.55 0.017 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
M S1 APARTMENT 383.67 460.41 0.017 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
M S2 APARTMENT 383.68 460.42 0.017 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F6 SW APARTMENT 964.49 1157.39 0.043 0.052 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F6 NW APARTMENT 964.87 1157.84 0.043 0.052 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F6 SE APARTMENT 964.49 1157.39 0.043 0.052 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F6 NE APARTMENT 964.87 1157.84 0.043 0.052 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F6 N1 APARTMENT 419.62 503.54 0.019 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F6 N2 APARTMENT 419.62 503.54 0.019 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F6 S1 APARTMENT 419.41 503.30 0.019 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F6 S2 APARTMENT 419.42 503.30 0.019 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F7 SW APARTMENT 993.67 1192.41 0.044 0.053 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F7 NW APARTMENT 994.71 1193.65 0.044 0.053 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F7 SE APARTMENT 993.67 1192.41 0.044 0.053 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F7 NE APARTMENT 994.71 1193.65 0.044 0.053 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F7 N1 APARTMENT 442.26 530.71 0.020 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F7 N2 APARTMENT 442.26 530.71 0.020 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F7 S1 APARTMENT 441.37 529.64 0.020 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F7 S2 APARTMENT 441.37 529.64 0.020 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F8 SW APARTMENT 1023.82 1228.59 0.046 0.055 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F8 NW APARTMENT 1025.34 1230.40 0.046 0.055 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F8 SE APARTMENT 1023.82 1228.59 0.046 0.055 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F8 NE APARTMENT 1025.34 1230.40 0.046 0.055 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F8 N1 APARTMENT 466.83 560.20 0.021 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F8 N2 APARTMENT 466.83 560.20 0.021 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F8 S1 APARTMENT 465.44 558.52 0.021 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F8 S2 APARTMENT 465.44 558.52 0.021 0.026 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F9 SW APARTMENT 1117.83 1341.40 0.050 0.060 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F9 NW APARTMENT 1118.59 1342.31 0.050 0.060 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F9 SE APARTMENT 1117.83 1341.40 0.050 0.060 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F9 NE APARTMENT 1118.59 1342.31 0.050 0.060 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F9 N1 APARTMENT 549.51 659.41 0.024 0.029 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F9 N2 APARTMENT 549.51 659.41 0.024 0.029 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F9 S1 APARTMENT 548.66 658.39 0.024 0.029 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
F9 S2 APARTMENT 548.66 658.39 0.024 0.029 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
T SW APARTMENT 1432.91 1719.49 0.064 0.077 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
T NW APARTMENT 1437.22 1724.66 0.064 0.077 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
T SE APARTMENT 1432.91 1719.49 0.064 0.077 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
T NE APARTMENT 1437.22 1724.66 0.064 0.077 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
T N1 APARTMENT 891.46 1069.76 0.040 0.048 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
T N2 APARTMENT 891.46 1069.76 0.040 0.048 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
T S1 APARTMENT 886.35 1063.62 0.039 0.047 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526
T S2 APARTMENT 886.35 1063.62 0.039 0.047 TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB 1/21 15:00:00 4.60 0.00526


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
AIRLOOP G SW 0.25 0.25 0.05 0.05
AIRLOOP G NW 0.23 0.23 0.05 0.05
AIRLOOP OFFICE 0.32 0.32 0.07 0.07
AIRLOOP G NE 0.19 0.19 0.05 0.05
AIRLOOP G N1 0.11 0.11 0.03 0.03
AIRLOOP G N2 0.11 0.11 0.03 0.03
AIRLOOP G S1 0.15 0.15 0.03 0.03
AIRLOOP G S2 0.15 0.15 0.03 0.03
AIRLOOP F2 SW 0.29 0.29 0.05 0.05
AIRLOOP F2 NW 0.27 0.27 0.05 0.05
AIRLOOP F2 SE 0.27 0.27 0.05 0.05
AIRLOOP F2 NE 0.23 0.23 0.05 0.05
AIRLOOP F2 N1 0.13 0.13 0.03 0.03
AIRLOOP F2 N2 0.13 0.13 0.03 0.03
AIRLOOP F2 S1 0.18 0.18 0.03 0.03
AIRLOOP F2 S2 0.18 0.18 0.03 0.03
AIRLOOP F3 SW 0.29 0.29 0.05 0.05
AIRLOOP F3 NW 0.27 0.27 0.05 0.05
AIRLOOP F3 SE 0.26 0.26 0.05 0.05
AIRLOOP F3 NE 0.23 0.23 0.05 0.05
AIRLOOP F3 N1 0.14 0.14 0.03 0.03
AIRLOOP F3 N2 0.13 0.13 0.03 0.03
AIRLOOP F3 S1 0.18 0.18 0.03 0.03
AIRLOOP F3 S2 0.18 0.18 0.03 0.03
AIRLOOP F4 SW 0.29 0.29 0.05 0.05
AIRLOOP F4 NW 0.27 0.27 0.05 0.05
AIRLOOP F4 SE 0.26 0.26 0.05 0.05
AIRLOOP F4 NE 0.23 0.23 0.05 0.05
AIRLOOP F4 N1 0.14 0.14 0.03 0.03
AIRLOOP F4 N2 0.14 0.14 0.03 0.03
AIRLOOP F4 S1 0.18 0.18 0.03 0.03
AIRLOOP F4 S2 0.18 0.18 0.03 0.03
AIRLOOP M SW 0.29 0.29 0.05 0.05
AIRLOOP M NW 0.27 0.27 0.05 0.05
AIRLOOP M SE 0.26 0.26 0.05 0.05
AIRLOOP M NE 0.23 0.23 0.05 0.05
AIRLOOP M N1 0.14 0.14 0.03 0.03
AIRLOOP M N2 0.14 0.14 0.03 0.03
AIRLOOP M S1 0.18 0.18 0.03 0.03
AIRLOOP M S2 0.18 0.18 0.03 0.03
AIRLOOP F6 SW 0.29 0.29 0.05 0.05
AIRLOOP F6 NW 0.27 0.27 0.05 0.05
AIRLOOP F6 SE 0.26 0.26 0.05 0.05
AIRLOOP F6 NE 0.23 0.23 0.05 0.05
AIRLOOP F6 N1 0.14 0.14 0.03 0.03
AIRLOOP F6 N2 0.14 0.14 0.03 0.03
AIRLOOP F6 S1 0.18 0.18 0.03 0.03
AIRLOOP F6 S2 0.18 0.18 0.03 0.03
AIRLOOP F7 SW 0.29 0.29 0.05 0.05
AIRLOOP F7 NW 0.27 0.27 0.05 0.05
AIRLOOP F7 SE 0.25 0.25 0.05 0.05
AIRLOOP F7 NE 0.23 0.23 0.05 0.05
AIRLOOP F7 N1 0.14 0.14 0.03 0.03
AIRLOOP F7 N2 0.14 0.14 0.03 0.03
AIRLOOP F7 S1 0.18 0.18 0.03 0.03
AIRLOOP F7 S2 0.18 0.18 0.03 0.03
AIRLOOP F8 SW 0.29 0.29 0.05 0.05
AIRLOOP F8 NW 0.27 0.27 0.05 0.05
AIRLOOP F8 SE 0.25 0.25 0.05 0.05
AIRLOOP F8 NE 0.23 0.23 0.05 0.05
AIRLOOP F8 N1 0.14 0.14 0.03 0.03
AIRLOOP F8 N2 0.14 0.14 0.03 0.03
AIRLOOP F8 S1 0.18 0.18 0.03 0.03
AIRLOOP F8 S2 0.18 0.18 0.03 0.03
AIRLOOP F9 SW 0.30 0.30 0.06 0.06
AIRLOOP F9 NW 0.28 0.28 0.06 0.06
AIRLOOP F9 SE 0.26 0.26 0.06 0.06
AIRLOOP F9 NE 0.23 0.23 0.06 0.06
AIRLOOP F9 N1 0.14 0.14 0.03 0.03
AIRLOOP F9 N2 0.14 0.14 0.03 0.03
AIRLOOP F9 S1 0.18 0.18 0.03 0.03
AIRLOOP F9 S2 0.18 0.18 0.03 0.03
AIRLOOP T SW 0.35 0.35 0.08 0.08
AIRLOOP T NW 0.33 0.33 0.08 0.08
AIRLOOP T SE 0.31 0.31 0.08 0.08
AIRLOOP T NE 0.27 0.27 0.08 0.08
AIRLOOP T N1 0.19 0.19 0.05 0.05
AIRLOOP T N2 0.19 0.19 0.05 0.05
AIRLOOP T S1 0.24 0.24 0.05 0.05
AIRLOOP T S2 0.24 0.24 0.05 0.05



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 6265.00 5203.75 3203.75
G NW APARTMENT 6004.75 5936.00 3406.75
OFFICE 1779.75 210.75 42.75
G NE APARTMENT 6012.75 5827.75 3301.25
G N1 APARTMENT 5969.25 6047.75 3388.50
G N2 APARTMENT 5968.75 6033.25 3374.00
G S1 APARTMENT 6202.75 5317.25 3262.00
G S2 APARTMENT 6213.75 5269.50 3247.50
F2 SW APARTMENT 6902.75 2791.00 1744.50
F2 NW APARTMENT 6304.75 4137.75 2111.75
F2 SE APARTMENT 6965.50 2530.00 1564.00
F2 NE APARTMENT 6285.00 4152.25 2071.25
F2 N1 APARTMENT 6207.00 4290.75 2121.50
F2 N2 APARTMENT 6204.75 4290.50 2121.50
F2 S1 APARTMENT 6936.00 2625.00 1716.00
F2 S2 APARTMENT 6945.50 2607.25 1709.75
F3 SW APARTMENT 7079.25 2583.00 1700.50
F3 NW APARTMENT 6417.25 3848.75 1983.25
F3 SE APARTMENT 7063.25 2482.00 1598.75
F3 NE APARTMENT 6413.00 3818.00 1916.50
F3 N1 APARTMENT 6339.75 3875.75 1917.75
F3 N2 APARTMENT 6337.00 3880.25 1920.00
F3 S1 APARTMENT 7178.00 2327.75 1662.00
F3 S2 APARTMENT 7181.25 2325.25 1663.00
F4 SW APARTMENT 7095.00 2604.00 1731.00
F4 NW APARTMENT 6444.25 3838.00 1994.25
F4 SE APARTMENT 7064.75 2524.75 1636.25
F4 NE APARTMENT 6430.50 3798.25 1922.75
F4 N1 APARTMENT 6376.75 3806.25 1896.75
F4 N2 APARTMENT 6373.75 3809.00 1896.00
F4 S1 APARTMENT 7216.75 2312.75 1674.50
F4 S2 APARTMENT 7215.50 2315.25 1676.25
M SW APARTMENT 7102.00 2597.75 1725.25
M NW APARTMENT 6457.25 3800.50 1970.25
M SE APARTMENT 7070.25 2526.00 1633.75
M NE APARTMENT 6444.75 3764.00 1899.00
M N1 APARTMENT 6405.00 3749.00 1866.00
M N2 APARTMENT 6402.25 3753.25 1865.25
M S1 APARTMENT 7236.00 2290.00 1663.00
M S2 APARTMENT 7235.25 2292.75 1664.75
F6 SW APARTMENT 7015.00 2795.25 1832.25
F6 NW APARTMENT 6395.00 4013.50 2103.50
F6 SE APARTMENT 6978.50 2718.00 1742.25
F6 NE APARTMENT 6394.00 3992.50 2034.25
F6 N1 APARTMENT 6340.25 3933.75 1970.00
F6 N2 APARTMENT 6337.25 3939.00 1971.25
F6 S1 APARTMENT 7142.25 2446.50 1733.00
F6 S2 APARTMENT 7141.00 2448.50 1733.00
F7 SW APARTMENT 6951.50 2932.50 1902.50
F7 NW APARTMENT 6361.50 4149.50 2182.00
F7 SE APARTMENT 6925.75 2851.75 1810.00
F7 NE APARTMENT 6361.50 4131.50 2111.50
F7 N1 APARTMENT 6305.50 4036.75 2018.00
F7 N2 APARTMENT 6305.50 4042.00 2018.00
F7 S1 APARTMENT 7086.50 2554.50 1778.00
F7 S2 APARTMENT 7082.50 2555.75 1779.25
F8 SW APARTMENT 6900.50 3032.00 1943.25
F8 NW APARTMENT 6337.50 4238.25 2227.75
F8 SE APARTMENT 6881.75 2956.00 1852.00
F8 NE APARTMENT 6330.00 4224.50 2158.00
F8 N1 APARTMENT 6283.50 4116.00 2050.25
F8 N2 APARTMENT 6280.00 4118.00 2052.25
F8 S1 APARTMENT 7030.75 2644.75 1805.50
F8 S2 APARTMENT 7027.75 2648.75 1807.25
F9 SW APARTMENT 6832.75 3127.50 1938.75
F9 NW APARTMENT 6310.25 4278.50 2205.50
F9 SE APARTMENT 6813.50 3058.50 1844.00
F9 NE APARTMENT 6287.75 4262.00 2138.75
F9 N1 APARTMENT 6254.75 4178.00 2055.00
F9 N2 APARTMENT 6251.00 4178.75 2054.25
F9 S1 APARTMENT 6942.25 2769.50 1808.25
F9 S2 APARTMENT 6939.75 2771.75 1808.75
T SW APARTMENT 6740.25 3931.50 2422.50
T NW APARTMENT 6315.75 4807.25 2659.50
T SE APARTMENT 6741.75 3930.00 2407.25
T NE APARTMENT 6303.50 4807.75 2611.25
T N1 APARTMENT 6260.25 4706.50 2469.00
T N2 APARTMENT 6260.25 4710.75 2471.25
T S1 APARTMENT 6799.25 3622.75 2269.00
T S2 APARTMENT 6799.00 3633.50 2279.00
G CORRIDOR 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00
Facility 7434.75 6460.00 3841.75
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 0.00 9.25 0.00 9.25
G NW APARTMENT 0.25 3.25 0.25 3.25
OFFICE 1.25 0.25 0.00 0.00
G NE APARTMENT 0.00 20.50 0.00 20.50
G N1 APARTMENT 1.50 124.75 1.50 124.75
G N2 APARTMENT 2.50 138.75 2.50 138.75
G S1 APARTMENT 1.00 96.50 1.00 96.50
G S2 APARTMENT 1.00 83.25 1.00 83.25
F2 SW APARTMENT 0.00 17.50 0.00 17.50
F2 NW APARTMENT 0.25 1.75 0.25 1.75
F2 SE APARTMENT 0.50 47.75 0.50 47.75
F2 NE APARTMENT 0.00 13.75 0.00 13.75
F2 N1 APARTMENT 0.50 146.00 0.50 146.00
F2 N2 APARTMENT 0.75 160.00 0.75 160.00
F2 S1 APARTMENT 0.00 195.75 0.00 195.75
F2 S2 APARTMENT 0.00 187.75 0.00 187.75
F3 SW APARTMENT 0.25 22.50 0.25 22.50
F3 NW APARTMENT 0.25 1.75 0.25 1.75
F3 SE APARTMENT 0.25 97.75 0.25 97.75
F3 NE APARTMENT 0.25 24.50 0.25 24.50
F3 N1 APARTMENT 0.50 207.75 0.50 207.75
F3 N2 APARTMENT 0.50 225.50 0.50 225.50
F3 S1 APARTMENT 0.00 249.25 0.00 249.25
F3 S2 APARTMENT 0.00 245.50 0.00 245.50
F4 SW APARTMENT 0.00 23.00 0.00 23.00
F4 NW APARTMENT 0.00 2.50 0.00 2.50
F4 SE APARTMENT 0.00 105.25 0.00 105.25
F4 NE APARTMENT 0.50 27.25 0.50 27.25
F4 N1 APARTMENT 0.50 224.50 0.50 224.50
F4 N2 APARTMENT 0.00 237.50 0.00 237.50
F4 S1 APARTMENT 0.00 257.25 0.00 257.25
F4 S2 APARTMENT 0.00 255.75 0.00 255.75
M SW APARTMENT 0.00 22.75 0.00 22.75
M NW APARTMENT 0.00 2.75 0.00 2.75
M SE APARTMENT 0.75 104.75 0.75 104.75
M NE APARTMENT 0.00 28.75 0.00 28.75
M N1 APARTMENT 0.25 231.50 0.25 231.50
M N2 APARTMENT 0.00 249.25 0.00 249.25
M S1 APARTMENT 0.00 259.50 0.00 259.50
M S2 APARTMENT 0.00 256.25 0.00 256.25
F6 SW APARTMENT 0.00 24.00 0.00 24.00
F6 NW APARTMENT 0.00 3.00 0.00 3.00
F6 SE APARTMENT 0.00 106.50 0.00 106.50
F6 NE APARTMENT 0.25 29.75 0.25 29.75
F6 N1 APARTMENT 0.50 240.75 0.50 240.75
F6 N2 APARTMENT 0.50 258.25 0.50 258.25
F6 S1 APARTMENT 0.00 267.75 0.00 267.75
F6 S2 APARTMENT 0.00 265.25 0.00 265.25
F7 SW APARTMENT 0.00 25.00 0.00 25.00
F7 NW APARTMENT 0.00 4.00 0.00 4.00
F7 SE APARTMENT 0.25 105.50 0.25 105.50
F7 NE APARTMENT 0.00 32.00 0.00 32.00
F7 N1 APARTMENT 0.75 246.00 0.75 246.00
F7 N2 APARTMENT 0.75 263.00 0.75 263.00
F7 S1 APARTMENT 0.00 268.75 0.00 268.75
F7 S2 APARTMENT 0.00 265.75 0.00 265.75
F8 SW APARTMENT 0.25 25.25 0.25 25.25
F8 NW APARTMENT 0.00 4.50 0.00 4.50
F8 SE APARTMENT 0.50 103.00 0.50 103.00
F8 NE APARTMENT 0.00 32.25 0.00 32.25
F8 N1 APARTMENT 1.25 252.25 1.25 252.25
F8 N2 APARTMENT 1.00 265.25 1.00 265.25
F8 S1 APARTMENT 0.00 268.50 0.00 268.50
F8 S2 APARTMENT 0.00 266.50 0.00 266.50
F9 SW APARTMENT 0.00 20.25 0.00 20.25
F9 NW APARTMENT 0.00 4.50 0.00 4.50
F9 SE APARTMENT 0.00 93.50 0.00 93.50
F9 NE APARTMENT 0.00 31.25 0.00 31.25
F9 N1 APARTMENT 1.00 219.25 1.00 219.25
F9 N2 APARTMENT 0.75 232.50 0.75 232.50
F9 S1 APARTMENT 0.00 241.00 0.00 241.00
F9 S2 APARTMENT 0.25 238.25 0.25 238.25
T SW APARTMENT 0.00 15.25 0.00 15.25
T NW APARTMENT 0.00 2.50 0.00 2.50
T SE APARTMENT 0.00 62.25 0.00 62.25
T NE APARTMENT 0.00 16.00 0.00 16.00
T N1 APARTMENT 0.75 70.25 0.75 70.25
T N2 APARTMENT 0.50 67.50 0.50 67.50
T S1 APARTMENT 0.00 115.25 0.00 115.25
T S2 APARTMENT 0.00 115.00 0.00 115.00
G CORRIDOR 0.00 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
Facility 20.00 565.25 18.75 565.00
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.356 0.075 0.000 0.389
G NW APARTMENT 1.71 2.50 268.96 0.356 0.075 0.000 0.377
OFFICE 0.94 1.00 268.96 0.521 0.085 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.356 0.075 0.000 0.377
G N1 APARTMENT 1.71 2.50 268.96 0.356 0.045 0.000 0.367
G N2 APARTMENT 1.71 2.50 268.97 0.356 0.045 0.000 0.367
G S1 APARTMENT 1.71 2.50 268.96 0.356 0.045 0.000 0.386
G S2 APARTMENT 1.71 2.50 268.97 0.356 0.045 0.000 0.387
F2 SW APARTMENT 1.71 2.50 268.96 0.356 0.108 0.000 0.448
F2 NW APARTMENT 1.71 2.50 268.96 0.356 0.107 0.000 0.439
F2 SE APARTMENT 1.71 2.50 268.96 0.356 0.108 0.000 0.449
F2 NE APARTMENT 1.71 2.50 268.96 0.356 0.107 0.000 0.439
F2 N1 APARTMENT 1.71 2.50 268.96 0.356 0.065 0.000 0.433
F2 N2 APARTMENT 1.71 2.50 268.97 0.356 0.065 0.000 0.433
F2 S1 APARTMENT 1.71 2.50 268.96 0.356 0.065 0.000 0.446
F2 S2 APARTMENT 1.71 2.50 268.97 0.356 0.065 0.000 0.446
F3 SW APARTMENT 1.71 2.50 268.96 0.356 0.127 0.000 0.488
F3 NW APARTMENT 1.71 2.50 268.96 0.356 0.127 0.000 0.480
F3 SE APARTMENT 1.71 2.50 268.96 0.356 0.127 0.000 0.488
F3 NE APARTMENT 1.71 2.50 268.96 0.356 0.127 0.000 0.480
F3 N1 APARTMENT 1.71 2.50 268.96 0.356 0.077 0.000 0.475
F3 N2 APARTMENT 1.71 2.50 268.97 0.356 0.077 0.000 0.475
F3 S1 APARTMENT 1.71 2.50 268.96 0.356 0.077 0.000 0.486
F3 S2 APARTMENT 1.71 2.50 268.97 0.356 0.077 0.000 0.486
F4 SW APARTMENT 1.71 2.50 268.96 0.356 0.142 0.000 0.514
F4 NW APARTMENT 1.71 2.50 268.96 0.356 0.142 0.000 0.508
F4 SE APARTMENT 1.71 2.50 268.96 0.356 0.142 0.000 0.514
F4 NE APARTMENT 1.71 2.50 268.96 0.356 0.142 0.000 0.507
F4 N1 APARTMENT 1.71 2.50 268.96 0.356 0.086 0.000 0.503
F4 N2 APARTMENT 1.71 2.50 268.97 0.356 0.086 0.000 0.503
F4 S1 APARTMENT 1.71 2.50 268.96 0.356 0.086 0.000 0.513
F4 S2 APARTMENT 1.71 2.50 268.97 0.356 0.086 0.000 0.513
M SW APARTMENT 1.71 2.50 268.96 0.356 0.155 0.000 0.537
M NW APARTMENT 1.71 2.50 268.96 0.356 0.155 0.000 0.531
M SE APARTMENT 1.71 2.50 268.96 0.356 0.155 0.000 0.537
M NE APARTMENT 1.71 2.50 268.96 0.356 0.155 0.000 0.530
M N1 APARTMENT 1.71 2.50 268.96 0.356 0.093 0.000 0.526
M N2 APARTMENT 1.71 2.50 268.97 0.356 0.093 0.000 0.526
M S1 APARTMENT 1.71 2.50 268.96 0.356 0.093 0.000 0.536
M S2 APARTMENT 1.71 2.50 268.97 0.356 0.093 0.000 0.536
F6 SW APARTMENT 1.71 2.50 268.96 0.356 0.165 0.000 0.558
F6 NW APARTMENT 1.71 2.50 268.96 0.356 0.165 0.000 0.552
F6 SE APARTMENT 1.71 2.50 268.96 0.356 0.165 0.000 0.558
F6 NE APARTMENT 1.71 2.50 268.96 0.356 0.165 0.000 0.552
F6 N1 APARTMENT 1.71 2.50 268.96 0.356 0.100 0.000 0.548
F6 N2 APARTMENT 1.71 2.50 268.97 0.356 0.100 0.000 0.547
F6 S1 APARTMENT 1.71 2.50 268.96 0.356 0.100 0.000 0.557
F6 S2 APARTMENT 1.71 2.50 268.97 0.356 0.100 0.000 0.557
F7 SW APARTMENT 1.71 2.50 268.96 0.356 0.175 0.000 0.577
F7 NW APARTMENT 1.71 2.50 268.96 0.356 0.174 0.000 0.570
F7 SE APARTMENT 1.71 2.50 268.96 0.356 0.175 0.000 0.577
F7 NE APARTMENT 1.71 2.50 268.96 0.356 0.174 0.000 0.570
F7 N1 APARTMENT 1.71 2.50 268.96 0.356 0.105 0.000 0.566
F7 N2 APARTMENT 1.71 2.50 268.97 0.356 0.105 0.000 0.566
F7 S1 APARTMENT 1.71 2.50 268.96 0.356 0.105 0.000 0.575
F7 S2 APARTMENT 1.71 2.50 268.97 0.356 0.105 0.000 0.575
F8 SW APARTMENT 1.71 2.50 268.96 0.356 0.183 0.000 0.595
F8 NW APARTMENT 1.71 2.50 268.96 0.356 0.183 0.000 0.588
F8 SE APARTMENT 1.71 2.50 268.96 0.356 0.183 0.000 0.595
F8 NE APARTMENT 1.71 2.50 268.96 0.356 0.183 0.000 0.588
F8 N1 APARTMENT 1.71 2.50 268.96 0.356 0.110 0.000 0.584
F8 N2 APARTMENT 1.71 2.50 268.97 0.356 0.110 0.000 0.584
F8 S1 APARTMENT 1.71 2.50 268.96 0.356 0.110 0.000 0.593
F8 S2 APARTMENT 1.71 2.50 268.97 0.356 0.110 0.000 0.593
F9 SW APARTMENT 1.71 2.50 268.96 0.356 0.191 0.000 0.611
F9 NW APARTMENT 1.71 2.50 268.96 0.356 0.191 0.000 0.604
F9 SE APARTMENT 1.71 2.50 268.96 0.356 0.191 0.000 0.611
F9 NE APARTMENT 1.71 2.50 268.96 0.356 0.191 0.000 0.604
F9 N1 APARTMENT 1.71 2.50 268.96 0.356 0.115 0.000 0.600
F9 N2 APARTMENT 1.71 2.50 268.97 0.356 0.115 0.000 0.600
F9 S1 APARTMENT 1.71 2.50 268.96 0.356 0.115 0.000 0.609
F9 S2 APARTMENT 1.71 2.50 268.97 0.356 0.115 0.000 0.609
T SW APARTMENT 1.71 2.50 268.96 0.356 0.198 0.000 0.623
T NW APARTMENT 1.71 2.50 268.96 0.356 0.198 0.000 0.618
T SE APARTMENT 1.71 2.50 268.96 0.356 0.198 0.000 0.623
T NE APARTMENT 1.71 2.50 268.96 0.356 0.198 0.000 0.618
T N1 APARTMENT 1.71 2.50 268.96 0.356 0.119 0.000 0.614
T N2 APARTMENT 1.71 2.50 268.97 0.356 0.119 0.000 0.615
T S1 APARTMENT 1.71 2.50 268.96 0.356 0.119 0.000 0.622
T S2 APARTMENT 1.71 2.50 268.97 0.356 0.119 0.000 0.622
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
OFFICE 0.94 1.00 268.96 0.504 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
F2 SW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F2 NW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F2 SE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F2 NE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F2 N1 APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F2 N2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
F2 S1 APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F2 S2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
F3 SW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F3 NW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F3 SE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F3 NE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F3 N1 APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F3 N2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
F3 S1 APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F3 S2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
F4 SW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F4 NW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F4 SE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F4 NE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F4 N1 APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F4 N2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
F4 S1 APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F4 S2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
F6 SW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F6 NW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F6 SE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F6 NE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F6 N1 APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F6 N2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
F6 S1 APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F6 S2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
F7 SW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F7 NW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F7 SE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F7 NE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F7 N1 APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F7 N2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
F7 S1 APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F7 S2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
F8 SW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F8 NW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F8 SE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F8 NE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F8 N1 APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F8 N2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
F8 S1 APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F8 S2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
F9 SW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F9 NW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F9 SE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F9 NE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F9 N1 APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F9 N2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
F9 S1 APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F9 S2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Surfaces by Class

Total Outdoors
Wall 420 140
Floor 90 9
Roof 90 9
Internal Mass 80 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 140 140
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 80
Conditioned Zones 80
Unconditioned Zones 10
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 4197
Defaulted Fields 814
Fields with Defaults 11307
Autosized Fields 1293
Autosizable Fields 1630
Autocalculated Fields 907
Autocalculatable Fields 1710



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 3570.48 57096.53 16-FEB-03:15 195062.84 10-AUG-20:00
Electricity:Building 1547.51 26803.46 01-JAN-03:15 79071.91 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity 416.41 7980.64 01-JAN-00:15 25049.15 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 348.50 6974.01 01-JAN-00:15 20603.34 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:OFFICE 29.50 508.27 01-JAN-00:15 2167.24 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 21.95 379.58 01-JAN-00:15 1622.33 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:G CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:G CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:F2 SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F2 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:F2 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:F3 SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F3 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:F3 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:F4 SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F4 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:F4 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:M SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:M CORRIDOR 37.06 1175.12 01-JAN-00:15 1175.12 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 37.06 1175.12 01-JAN-00:15 1175.12 01-JAN-00:15
Electricity:Zone:F6 SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F6 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:F6 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:F7 SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F7 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:F7 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:F8 SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F8 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:F8 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:F9 SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:F9 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
InteriorLights:Electricity:Zone:F9 CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
Electricity:Zone:T SW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 14.63 238.08 01-JAN-03:15 783.07 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 2.41 14.40 01-JAN-00:15 230.46 01-JAN-19:15
Electricity:Zone:T CORRIDOR 177.27 1611.36 01-JAN-00:15 10825.51 01-JAN-07:15
InteriorLights:Electricity:Zone:T CORRIDOR 18.53 587.56 01-JAN-00:15 587.56 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 67.92 1006.63 01-JAN-00:15 4445.81 01-JAN-19:15
InteriorEquipment:Electricity 1131.09 18822.82 01-JAN-03:15 56933.81 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 1131.09 18822.82 01-JAN-03:15 56933.81 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 7.55 128.69 01-JAN-00:15 544.91 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T CORRIDOR 158.74 1023.79 01-JAN-00:15 10237.95 01-JAN-07:15
Fans:Electricity 604.09 19155.52 01-JAN-00:15 19155.52 01-JAN-00:15
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Electricity:HVAC 1742.51 19536.05 16-FEB-03:15 106192.26 10-SEP-15:15
ElectricityProduced:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityProduced:HVAC 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricityProduced 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 3570.48 57096.53 16-FEB-03:15 195062.84 10-AUG-20:00
ElectricityPurchased:Plant 3570.48 57096.53 16-FEB-03:15 195062.84 10-AUG-20:00
Cogeneration:ElectricityPurchased 3570.48 57096.53 16-FEB-03:15 195062.84 10-AUG-20:00
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 3570.48 57096.53 16-FEB-03:15 195062.84 10-AUG-20:00
ElectricityNet:Plant 3570.48 57096.53 16-FEB-03:15 195062.84 10-AUG-20:00
Cogeneration:ElectricityNet 3570.48 57096.53 16-FEB-03:15 195062.84 10-AUG-20:00
ExteriorLights:Electricity 168.41 0.00 01-JAN-07:30 10720.10 01-JAN-00:15
General:ExteriorLights:Electricity 168.41 0.00 01-JAN-07:30 10720.10 01-JAN-00:15
General:Fans:Electricity 604.09 19155.52 01-JAN-00:15 19155.52 01-JAN-00:15
Cooling:Electricity 1107.49 0.00 01-JAN-06:15 86232.69 10-SEP-15:15
Heating:Electricity 10.11 0.00 01-JAN-00:15 28235.03 05-FEB-07:15
Electricity:Plant 112.06 36.93 01-JAN-06:45 5312.47 28-APR-16:00
HeatRejection:Electricity 55.24 0.00 01-JAN-06:45 3451.82 28-APR-16:00
Boiler Parasitic:Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Pumps:Electricity 56.82 36.93 01-JAN-06:45 1860.65 01-JAN-00:15
WIRED_LTG_ELECTRICITY 0.62 0.00 01-JAN-00:15 37.57 01-JAN-19:30
WIRED_INT_EQUIP 973.17 1018.50 01-JAN-00:15 10185.00 01-JAN-07:15


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 907.21 9260.51 01-JAN-00:15 179729.28 05-FEB-07:15
Gas:Plant 907.21 9260.51 01-JAN-00:15 179729.28 05-FEB-07:15
WaterSystems:Gas 894.05 9260.51 01-JAN-00:15 80070.66 22-JAN-08:00
Water Heater:WaterSystems:Gas 894.05 9260.51 01-JAN-00:15 80070.66 22-JAN-08:00
Heating:Gas 13.16 0.00 01-JAN-00:15 100597.46 05-FEB-07:15
Boiler:Heating:Gas 13.16 0.00 01-JAN-00:15 100597.46 05-FEB-07:15


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
PlantLoopCoolingDemand:Facility 4974.32 0.00 01-JAN-06:15 428359.87 10-AUG-20:15
PlantLoopCoolingDemand:HVAC 4974.32 0.00 01-JAN-06:15 428359.87 10-AUG-20:15
CoolingCoils:PlantLoopCoolingDemand 4974.32 0.00 01-JAN-06:15 428359.87 10-AUG-20:15


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 7555.94 0.00 03-JAN-04:00 0.00 09-SEP-17:15
Water:Plant 7555.94 0.00 03-JAN-04:00 0.00 09-SEP-17:15
WaterSystems:Water 4778.51 0.00 01-JAN-02:30 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
MainsWater:Facility 7555.94 0.00 03-JAN-04:00 0.00 09-SEP-17:15
MainsWater:Plant 7555.94 0.00 03-JAN-04:00 0.00 09-SEP-17:15
WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:30 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
sub cat:WaterSystems:Water 4778.51 0.00 01-JAN-02:30 0.00 01-JAN-07:15
sub cat:WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:30 0.00 01-JAN-07:15
HeatRejection:Water 2777.43 0.00 01-JAN-06:45 0.00 30-AUG-16:15
HeatRejection:MainsWater 2777.43 0.00 01-JAN-06:45 0.00 30-AUG-16:15


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 704.03 362.54 24-JUL-01:15 129453.45 05-FEB-07:15
PlantLoopHeatingDemand:Plant 677.27 362.54 24-JUL-01:15 46852.93 24-JAN-07:15
WaterSystems:PlantLoopHeatingDemand 677.27 362.54 24-JUL-01:15 46852.93 24-JAN-07:15
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 6766.07 5617.16 04-MAR-03:45 516123.60 10-SEP-16:15
EnergyTransfer:Building 2110.70 3447.73 15-FEB-22:15 191304.41 30-AUG-16:15
EnergyTransfer:Zone:G SW APARTMENT 21.52 0.01 11-MAR-19:00 3090.24 30-AUG-15:30
Heating:EnergyTransfer 40.01 0.00 01-JAN-12:45 63984.04 05-FEB-07:15
Heating:EnergyTransfer:Zone:G SW APARTMENT 0.81 0.00 01-JAN-09:30 1066.97 20-DEC-07:30
Cooling:EnergyTransfer 2070.68 0.00 08-JAN-09:30 191304.41 30-AUG-16:15
Cooling:EnergyTransfer:Zone:G SW APARTMENT 20.71 0.00 01-JAN-00:15 3090.24 30-AUG-15:30
EnergyTransfer:Zone:G NW APARTMENT 17.67 0.00 05-DEC-11:15 2836.41 12-JUN-17:15
Heating:EnergyTransfer:Zone:G NW APARTMENT 1.41 0.00 01-JAN-11:45 1252.26 05-FEB-08:15
Cooling:EnergyTransfer:Zone:G NW APARTMENT 16.26 0.00 01-JAN-00:15 2836.41 12-JUN-17:15
EnergyTransfer:Zone:OFFICE 27.13 0.03 25-FEB-02:45 3438.98 01-SEP-11:00
Heating:EnergyTransfer:Zone:OFFICE 0.60 0.00 01-JAN-07:30 1273.85 05-FEB-07:15
Cooling:EnergyTransfer:Zone:OFFICE 26.53 0.00 01-JAN-00:15 3438.98 01-SEP-11:00
EnergyTransfer:Zone:G NE APARTMENT 17.58 0.06 09-NOV-24:00 2137.21 28-JUN-10:30
Heating:EnergyTransfer:Zone:G NE APARTMENT 1.19 0.00 01-JAN-05:15 1174.38 20-DEC-07:30
Cooling:EnergyTransfer:Zone:G NE APARTMENT 16.39 0.00 01-JAN-00:15 2137.21 28-JUN-10:30
EnergyTransfer:Zone:G N1 APARTMENT 12.51 0.01 28-OCT-18:30 1418.14 12-JUN-17:15
Heating:EnergyTransfer:Zone:G N1 APARTMENT 0.47 0.00 01-JAN-00:15 775.06 10-MAR-13:45
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 12.04 0.00 01-JAN-08:00 1418.14 12-JUN-17:15
EnergyTransfer:Zone:G N2 APARTMENT 12.52 0.01 23-NOV-15:30 1406.22 12-JUN-17:15
Heating:EnergyTransfer:Zone:G N2 APARTMENT 0.47 0.00 01-JAN-00:15 775.15 10-MAR-13:45
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 12.05 0.00 01-JAN-07:45 1406.22 12-JUN-17:15
EnergyTransfer:Zone:G S1 APARTMENT 16.65 0.00 08-DEC-21:15 2053.87 01-JAN-14:00
Heating:EnergyTransfer:Zone:G S1 APARTMENT 0.12 0.00 01-JAN-00:15 549.13 10-MAR-13:45
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 16.53 0.00 01-JAN-06:15 2053.87 01-JAN-14:00
EnergyTransfer:Zone:G S2 APARTMENT 16.90 0.02 15-APR-17:45 2100.41 01-JAN-14:00
Heating:EnergyTransfer:Zone:G S2 APARTMENT 0.12 0.00 01-JAN-00:15 500.36 10-MAR-13:45
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 16.78 0.00 01-JAN-06:15 2100.41 01-JAN-14:00
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F2 SW APARTMENT 31.81 0.06 11-FEB-02:45 3788.31 06-NOV-15:15
Heating:EnergyTransfer:Zone:F2 SW APARTMENT 0.37 0.00 01-JAN-00:15 871.28 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT 31.45 0.00 01-JAN-06:15 3788.31 06-NOV-15:15
EnergyTransfer:Zone:F2 NW APARTMENT 25.32 0.00 29-OCT-04:30 3315.58 12-JUN-17:15
Heating:EnergyTransfer:Zone:F2 NW APARTMENT 0.85 0.00 01-JAN-00:15 1034.23 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT 24.47 0.00 01-JAN-04:30 3315.58 12-JUN-17:15
EnergyTransfer:Zone:F2 SE APARTMENT 33.18 0.16 12-APR-01:15 3379.29 06-NOV-13:30
Heating:EnergyTransfer:Zone:F2 SE APARTMENT 0.28 0.00 01-JAN-00:15 877.48 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT 32.90 0.00 01-JAN-06:15 3379.29 06-NOV-13:30
EnergyTransfer:Zone:F2 NE APARTMENT 25.38 0.02 23-JAN-14:15 2577.30 13-JUN-09:45
Heating:EnergyTransfer:Zone:F2 NE APARTMENT 0.69 0.00 01-JAN-00:15 1055.73 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT 24.69 0.00 01-JAN-02:30 2577.30 13-JUN-09:45
EnergyTransfer:Zone:F2 N1 APARTMENT 19.49 0.04 12-MAR-05:00 1751.45 12-JUN-17:15
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT 0.17 0.00 01-JAN-00:15 612.33 10-MAR-13:45
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT 19.32 0.00 01-JAN-09:15 1751.45 12-JUN-17:15
EnergyTransfer:Zone:F2 N2 APARTMENT 19.49 0.03 20-NOV-18:45 1742.09 12-JUN-17:15
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT 0.17 0.00 01-JAN-00:15 613.52 10-MAR-13:45
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT 19.32 0.00 01-JAN-09:15 1742.09 12-JUN-17:15
EnergyTransfer:Zone:F2 S1 APARTMENT 26.08 0.02 31-MAR-05:45 2598.18 02-DEC-13:15
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT 0.04 0.00 01-JAN-00:15 255.80 05-FEB-04:15
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT 26.03 0.00 01-JAN-06:15 2598.18 02-DEC-13:15
EnergyTransfer:Zone:F2 S2 APARTMENT 26.19 0.01 17-JAN-08:45 2617.34 02-DEC-13:15
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT 0.04 0.00 01-JAN-00:15 107.04 16-FEB-06:15
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT 26.15 0.00 01-JAN-06:15 2617.34 02-DEC-13:15
EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F3 SW APARTMENT 33.39 0.00 06-FEB-23:45 3833.16 06-NOV-15:30
Heating:EnergyTransfer:Zone:F3 SW APARTMENT 0.31 0.00 01-JAN-00:15 859.14 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT 33.08 0.00 01-JAN-06:15 3833.16 06-NOV-15:30
EnergyTransfer:Zone:F3 NW APARTMENT 26.69 0.02 07-DEC-05:15 3334.26 12-JUN-17:15
Heating:EnergyTransfer:Zone:F3 NW APARTMENT 0.74 0.00 01-JAN-00:15 1042.45 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT 25.95 0.00 01-JAN-06:15 3334.26 12-JUN-17:15
EnergyTransfer:Zone:F3 SE APARTMENT 33.62 0.08 02-APR-01:15 3345.82 10-DEC-13:45
Heating:EnergyTransfer:Zone:F3 SE APARTMENT 0.23 0.00 01-JAN-00:15 874.89 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT 33.39 0.00 01-JAN-06:15 3345.82 10-DEC-13:45
EnergyTransfer:Zone:F3 NE APARTMENT 26.75 0.04 20-NOV-03:30 2585.47 13-JUN-09:45
Heating:EnergyTransfer:Zone:F3 NE APARTMENT 0.59 0.00 01-JAN-00:15 1062.13 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT 26.16 0.00 01-JAN-06:15 2585.47 13-JUN-09:45
EnergyTransfer:Zone:F3 N1 APARTMENT 21.03 0.00 28-OCT-19:00 1784.74 12-JUN-17:15
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT 0.12 0.00 01-JAN-00:15 663.43 23-DEC-11:00
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT 20.91 0.00 01-JAN-09:15 1784.74 12-JUN-17:15
EnergyTransfer:Zone:F3 N2 APARTMENT 21.03 0.02 22-DEC-12:15 1775.40 12-JUN-17:15
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT 0.12 0.00 01-JAN-00:15 666.41 23-DEC-11:00
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT 20.91 0.00 01-JAN-09:15 1775.40 12-JUN-17:15
EnergyTransfer:Zone:F3 S1 APARTMENT 28.06 0.05 04-APR-07:00 2642.02 02-DEC-13:00
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT 0.03 0.00 01-JAN-00:15 114.70 16-FEB-06:15
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT 28.03 0.00 01-JAN-06:15 2642.02 02-DEC-13:00
EnergyTransfer:Zone:F3 S2 APARTMENT 28.09 0.00 20-MAR-10:15 2651.00 02-DEC-13:00
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT 0.03 0.00 01-JAN-00:15 115.93 16-FEB-06:15
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT 28.06 0.00 01-JAN-06:15 2651.00 02-DEC-13:00
EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F4 SW APARTMENT 33.56 0.08 07-DEC-04:45 3845.08 06-NOV-15:30
Heating:EnergyTransfer:Zone:F4 SW APARTMENT 0.32 0.00 01-JAN-00:15 908.94 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT 33.24 0.00 01-JAN-06:15 3845.08 06-NOV-15:30
EnergyTransfer:Zone:F4 NW APARTMENT 26.99 0.00 04-MAR-06:45 3341.23 12-JUN-17:15
Heating:EnergyTransfer:Zone:F4 NW APARTMENT 0.75 0.00 01-JAN-00:15 1098.38 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT 26.24 0.00 01-JAN-06:15 3341.23 12-JUN-17:15
EnergyTransfer:Zone:F4 SE APARTMENT 33.64 0.01 02-MAR-02:15 3351.81 01-JAN-14:00
Heating:EnergyTransfer:Zone:F4 SE APARTMENT 0.24 0.00 01-JAN-00:15 928.32 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT 33.41 0.00 01-JAN-06:15 3351.81 01-JAN-14:00
EnergyTransfer:Zone:F4 NE APARTMENT 27.05 0.02 10-NOV-02:45 2598.26 08-JUL-11:00
Heating:EnergyTransfer:Zone:F4 NE APARTMENT 0.61 0.00 01-JAN-00:15 1115.42 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT 26.45 0.00 01-JAN-06:15 2598.26 08-JUL-11:00
EnergyTransfer:Zone:F4 N1 APARTMENT 21.44 0.02 27-NOV-21:45 1805.60 12-JUN-17:15
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT 0.13 0.00 01-JAN-00:15 769.35 23-DEC-11:00
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT 21.31 0.00 01-JAN-09:15 1805.60 12-JUN-17:15
EnergyTransfer:Zone:F4 N2 APARTMENT 21.44 0.01 14-NOV-10:00 1796.32 12-JUN-17:15
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT 0.12 0.00 01-JAN-00:15 776.65 23-DEC-11:00
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT 21.31 0.00 01-JAN-09:15 1796.32 12-JUN-17:15
EnergyTransfer:Zone:F4 S1 APARTMENT 28.41 0.06 08-APR-06:45 2655.68 02-DEC-13:00
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT 0.03 0.00 01-JAN-00:15 124.17 16-FEB-06:15
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT 28.38 0.00 01-JAN-06:15 2655.68 02-DEC-13:00
EnergyTransfer:Zone:F4 S2 APARTMENT 28.42 0.02 17-NOV-20:15 2663.05 02-DEC-13:00
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT 0.03 0.00 01-JAN-00:15 125.07 16-FEB-06:15
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT 28.39 0.00 01-JAN-06:15 2663.05 02-DEC-13:00
EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M SW APARTMENT 34.03 0.18 08-MAR-03:30 3879.12 06-NOV-15:30
Heating:EnergyTransfer:Zone:M SW APARTMENT 0.33 0.00 01-JAN-00:15 957.19 05-FEB-07:15
Cooling:EnergyTransfer:Zone:M SW APARTMENT 33.70 0.00 01-JAN-06:15 3879.12 06-NOV-15:30
EnergyTransfer:Zone:M NW APARTMENT 27.58 0.06 21-MAR-19:30 3369.95 12-JUN-17:15
Heating:EnergyTransfer:Zone:M NW APARTMENT 0.78 0.00 01-JAN-00:15 1146.69 05-FEB-07:15
Cooling:EnergyTransfer:Zone:M NW APARTMENT 26.80 0.00 01-JAN-06:15 3369.95 12-JUN-17:15
EnergyTransfer:Zone:M SE APARTMENT 34.09 0.03 31-JAN-21:15 3367.99 01-JAN-14:00
Heating:EnergyTransfer:Zone:M SE APARTMENT 0.25 0.00 01-JAN-00:15 977.52 05-FEB-07:15
Cooling:EnergyTransfer:Zone:M SE APARTMENT 33.84 0.00 01-JAN-06:15 3367.99 01-JAN-14:00
EnergyTransfer:Zone:M NE APARTMENT 27.63 0.04 05-MAR-05:15 2628.48 13-JUN-09:45
Heating:EnergyTransfer:Zone:M NE APARTMENT 0.63 0.00 01-JAN-00:15 1161.43 05-FEB-07:15
Cooling:EnergyTransfer:Zone:M NE APARTMENT 27.00 0.00 01-JAN-06:15 2628.48 13-JUN-09:45
EnergyTransfer:Zone:M N1 APARTMENT 22.07 0.00 16-APR-06:30 1848.39 12-JUN-17:15
Heating:EnergyTransfer:Zone:M N1 APARTMENT 0.14 0.00 01-JAN-00:15 846.38 23-DEC-11:00
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 21.94 0.00 01-JAN-09:15 1848.39 12-JUN-17:15
EnergyTransfer:Zone:M N2 APARTMENT 22.07 0.05 29-NOV-21:30 1839.15 12-JUN-17:15
Heating:EnergyTransfer:Zone:M N2 APARTMENT 0.14 0.00 01-JAN-00:15 850.71 23-DEC-11:00
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 21.94 0.00 01-JAN-09:15 1839.15 12-JUN-17:15
EnergyTransfer:Zone:M S1 APARTMENT 28.99 0.01 15-FEB-08:00 2689.79 02-DEC-13:00
Heating:EnergyTransfer:Zone:M S1 APARTMENT 0.04 0.00 01-JAN-00:15 131.23 16-FEB-06:15
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 28.95 0.00 01-JAN-06:15 2689.79 02-DEC-13:00
EnergyTransfer:Zone:M S2 APARTMENT 29.00 0.00 09-NOV-20:00 2696.89 02-DEC-13:00
Heating:EnergyTransfer:Zone:M S2 APARTMENT 0.04 0.00 01-JAN-00:15 132.09 16-FEB-06:15
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 28.97 0.00 01-JAN-06:15 2696.89 02-DEC-13:00
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F6 SW APARTMENT 32.96 0.08 09-FEB-11:15 3839.32 06-NOV-15:30
Heating:EnergyTransfer:Zone:F6 SW APARTMENT 0.37 0.00 01-JAN-00:15 1057.81 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT 32.58 0.00 01-JAN-06:15 3839.32 06-NOV-15:30
EnergyTransfer:Zone:F6 NW APARTMENT 26.87 0.02 18-OCT-04:45 3330.81 12-JUN-17:15
Heating:EnergyTransfer:Zone:F6 NW APARTMENT 0.90 0.00 01-JAN-00:15 1237.69 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT 25.96 0.00 01-JAN-06:15 3330.81 12-JUN-17:15
EnergyTransfer:Zone:F6 SE APARTMENT 33.01 0.03 08-APR-13:30 3321.48 06-NOV-14:15
Heating:EnergyTransfer:Zone:F6 SE APARTMENT 0.29 0.00 01-JAN-00:15 1076.15 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT 32.72 0.00 01-JAN-06:15 3321.48 06-NOV-14:15
EnergyTransfer:Zone:F6 NE APARTMENT 26.90 0.00 20-NOV-04:45 2591.26 13-JUN-09:45
Heating:EnergyTransfer:Zone:F6 NE APARTMENT 0.74 0.00 01-JAN-00:15 1250.93 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT 26.15 0.00 01-JAN-06:15 2591.26 13-JUN-09:45
EnergyTransfer:Zone:F6 N1 APARTMENT 21.33 0.00 10-APR-11:15 1818.74 12-JUN-17:15
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT 0.18 0.00 01-JAN-00:15 986.38 23-DEC-11:00
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT 21.15 0.00 01-JAN-09:15 1818.74 12-JUN-17:15
EnergyTransfer:Zone:F6 N2 APARTMENT 21.33 0.01 27-NOV-21:00 1809.61 12-JUN-17:15
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT 0.18 0.00 01-JAN-00:15 992.03 23-DEC-11:00
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT 21.15 0.00 01-JAN-09:15 1809.61 12-JUN-17:15
EnergyTransfer:Zone:F6 S1 APARTMENT 27.92 0.02 02-JAN-21:15 2649.96 02-DEC-13:00
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT 0.04 0.00 01-JAN-00:15 200.82 20-MAR-17:00
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT 27.88 0.00 01-JAN-06:15 2649.96 02-DEC-13:00
EnergyTransfer:Zone:F6 S2 APARTMENT 27.94 0.01 13-NOV-20:45 2657.01 02-DEC-13:00
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT 0.04 0.00 01-JAN-00:15 195.01 20-MAR-17:00
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT 27.89 0.00 01-JAN-06:15 2657.01 02-DEC-13:00
EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F7 SW APARTMENT 32.43 0.01 02-FEB-21:15 3825.61 06-NOV-15:30
Heating:EnergyTransfer:Zone:F7 SW APARTMENT 0.42 0.00 01-JAN-00:15 1136.18 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT 32.01 0.00 01-JAN-06:15 3825.61 06-NOV-15:30
EnergyTransfer:Zone:F7 NW APARTMENT 26.62 0.06 23-MAR-22:45 3316.58 12-JUN-17:15
Heating:EnergyTransfer:Zone:F7 NW APARTMENT 1.01 0.00 01-JAN-00:15 1308.34 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT 25.60 0.00 01-JAN-05:00 3316.58 12-JUN-17:15
EnergyTransfer:Zone:F7 SE APARTMENT 32.48 0.07 02-MAR-01:45 3311.17 06-NOV-14:15
Heating:EnergyTransfer:Zone:F7 SE APARTMENT 0.33 0.00 01-JAN-00:15 1151.92 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT 32.15 0.00 01-JAN-06:15 3311.17 06-NOV-14:15
EnergyTransfer:Zone:F7 NE APARTMENT 26.63 0.01 11-DEC-09:00 2580.10 13-JUN-09:45
Heating:EnergyTransfer:Zone:F7 NE APARTMENT 0.85 0.00 01-JAN-00:15 1320.68 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT 25.78 0.00 01-JAN-06:15 2580.10 13-JUN-09:45
EnergyTransfer:Zone:F7 N1 APARTMENT 21.04 0.05 08-APR-18:15 1814.22 12-JUN-17:15
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT 0.23 0.00 01-JAN-00:15 1077.21 23-DEC-11:00
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT 20.81 0.00 01-JAN-09:00 1814.22 12-JUN-17:15
EnergyTransfer:Zone:F7 N2 APARTMENT 21.04 0.05 10-APR-11:15 1805.16 12-JUN-17:15
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT 0.23 0.00 01-JAN-00:15 1077.87 23-DEC-11:00
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT 20.81 0.00 01-JAN-09:00 1805.16 12-JUN-17:15
EnergyTransfer:Zone:F7 S1 APARTMENT 27.41 0.00 21-FEB-07:00 2636.06 02-DEC-13:00
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT 0.05 0.00 01-JAN-00:15 391.79 20-MAR-17:00
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT 27.36 0.00 01-JAN-06:15 2636.06 02-DEC-13:00
EnergyTransfer:Zone:F7 S2 APARTMENT 27.42 0.00 05-FEB-04:30 2643.07 02-DEC-13:00
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT 0.05 0.00 01-JAN-00:15 385.35 20-MAR-17:00
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT 27.37 0.00 01-JAN-06:15 2643.07 02-DEC-13:00
EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F8 SW APARTMENT 32.18 0.09 21-MAR-14:45 3825.31 06-NOV-15:30
Heating:EnergyTransfer:Zone:F8 SW APARTMENT 0.47 0.00 01-JAN-00:15 1209.37 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT 31.71 0.00 01-JAN-06:15 3825.31 06-NOV-15:30
EnergyTransfer:Zone:F8 NW APARTMENT 26.61 0.02 14-NOV-19:00 3316.42 12-JUN-17:15
Heating:EnergyTransfer:Zone:F8 NW APARTMENT 1.13 0.00 01-JAN-00:15 1381.46 05-FEB-08:00
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT 25.49 0.00 01-JAN-05:00 3316.42 12-JUN-17:15
EnergyTransfer:Zone:F8 SE APARTMENT 32.22 0.03 12-MAR-18:15 3314.98 06-NOV-14:15
Heating:EnergyTransfer:Zone:F8 SE APARTMENT 0.38 0.00 01-JAN-00:15 1221.92 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT 31.84 0.00 01-JAN-06:15 3314.98 06-NOV-14:15
EnergyTransfer:Zone:F8 NE APARTMENT 26.62 0.02 14-NOV-05:30 2582.41 28-JUN-10:30
Heating:EnergyTransfer:Zone:F8 NE APARTMENT 0.96 0.00 01-JAN-00:15 1391.21 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT 25.66 0.00 01-JAN-06:15 2582.41 28-JUN-10:30
EnergyTransfer:Zone:F8 N1 APARTMENT 20.99 0.02 18-NOV-20:00 1824.60 12-JUN-17:15
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT 0.28 0.00 01-JAN-00:15 1178.46 23-DEC-11:00
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT 20.70 0.00 01-JAN-09:00 1824.60 12-JUN-17:15
EnergyTransfer:Zone:F8 N2 APARTMENT 20.99 0.01 16-APR-09:45 1815.63 12-JUN-17:15
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT 0.28 0.00 01-JAN-00:15 1176.87 23-DEC-11:00
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT 20.70 0.00 01-JAN-09:00 1815.63 12-JUN-17:15
EnergyTransfer:Zone:F8 S1 APARTMENT 27.14 0.00 09-APR-09:15 2636.10 02-DEC-13:00
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT 0.06 0.00 01-JAN-00:15 564.33 20-MAR-17:00
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT 27.08 0.00 01-JAN-06:15 2636.10 02-DEC-13:00
EnergyTransfer:Zone:F8 S2 APARTMENT 27.16 0.01 24-MAR-21:00 2643.07 02-DEC-13:00
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT 0.06 0.00 01-JAN-00:15 556.97 20-MAR-17:00
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT 27.09 0.00 01-JAN-06:15 2643.07 02-DEC-13:00
EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F9 SW APARTMENT 32.52 0.01 10-FEB-02:45 3864.01 06-NOV-15:15
Heating:EnergyTransfer:Zone:F9 SW APARTMENT 0.58 0.00 01-JAN-00:15 1343.67 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT 31.94 0.00 01-JAN-06:15 3864.01 06-NOV-15:15
EnergyTransfer:Zone:F9 NW APARTMENT 27.31 0.01 20-JAN-11:45 3402.31 12-JUN-17:15
Heating:EnergyTransfer:Zone:F9 NW APARTMENT 1.35 0.00 01-JAN-00:15 1546.13 05-FEB-08:00
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT 25.95 0.00 01-JAN-04:45 3402.31 12-JUN-17:15
EnergyTransfer:Zone:F9 SE APARTMENT 32.54 0.01 16-MAR-01:45 3349.83 06-NOV-14:00
Heating:EnergyTransfer:Zone:F9 SE APARTMENT 0.47 0.00 01-JAN-00:15 1357.46 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT 32.07 0.00 01-JAN-06:15 3349.83 06-NOV-14:00
EnergyTransfer:Zone:F9 NE APARTMENT 27.27 0.00 07-DEC-24:00 2621.49 28-JUN-10:30
Heating:EnergyTransfer:Zone:F9 NE APARTMENT 1.15 0.00 01-JAN-00:15 1549.38 05-FEB-07:15
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT 26.12 0.00 01-JAN-04:45 2621.49 28-JUN-10:30
EnergyTransfer:Zone:F9 N1 APARTMENT 21.51 0.02 01-DEC-16:45 1903.99 12-JUN-17:15
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT 0.39 0.00 01-JAN-00:15 1300.78 23-DEC-11:00
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT 21.12 0.00 01-JAN-06:15 1903.99 12-JUN-17:15
EnergyTransfer:Zone:F9 N2 APARTMENT 21.51 0.00 07-DEC-22:00 1896.25 12-JUN-17:15
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT 0.39 0.00 01-JAN-00:15 1302.20 23-DEC-11:00
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT 21.12 0.00 01-JAN-06:15 1896.25 12-JUN-17:15
EnergyTransfer:Zone:F9 S1 APARTMENT 27.37 0.03 21-NOV-07:00 2680.83 02-DEC-13:15
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT 0.09 0.00 01-JAN-00:15 763.89 20-MAR-17:00
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT 27.28 0.00 01-JAN-06:15 2680.83 02-DEC-13:15
EnergyTransfer:Zone:F9 S2 APARTMENT 27.39 0.01 11-APR-09:45 2688.31 02-DEC-13:15
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT 0.09 0.00 01-JAN-00:15 755.92 20-MAR-17:00
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT 27.29 0.00 01-JAN-06:15 2688.31 02-DEC-13:15
EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:T SW APARTMENT 34.57 0.02 15-NOV-24:00 4560.64 06-NOV-14:30
Heating:EnergyTransfer:Zone:T SW APARTMENT 1.71 0.00 01-JAN-00:15 2108.53 05-FEB-07:15
Cooling:EnergyTransfer:Zone:T SW APARTMENT 32.86 0.00 01-JAN-02:00 4560.64 06-NOV-14:30
EnergyTransfer:Zone:T NW APARTMENT 29.87 0.01 24-JAN-21:45 4134.98 12-JUN-16:30
Heating:EnergyTransfer:Zone:T NW APARTMENT 2.74 0.00 01-JAN-00:15 2236.72 05-FEB-07:15
Cooling:EnergyTransfer:Zone:T NW APARTMENT 27.13 0.00 01-JAN-00:30 4134.98 12-JUN-16:30
EnergyTransfer:Zone:T SE APARTMENT 34.29 0.04 12-DEC-09:00 3968.94 06-NOV-14:15
Heating:EnergyTransfer:Zone:T SE APARTMENT 1.48 0.00 01-JAN-00:15 2120.36 05-FEB-07:15
Cooling:EnergyTransfer:Zone:T SE APARTMENT 32.81 0.00 01-JAN-02:00 3968.94 06-NOV-14:15
EnergyTransfer:Zone:T NE APARTMENT 29.43 0.01 02-MAR-19:15 3219.01 08-JUL-11:30
Heating:EnergyTransfer:Zone:T NE APARTMENT 2.33 0.00 01-JAN-00:15 2243.94 05-FEB-07:15
Cooling:EnergyTransfer:Zone:T NE APARTMENT 27.09 0.00 01-JAN-00:30 3219.01 08-JUL-11:30
EnergyTransfer:Zone:T N1 APARTMENT 23.20 0.13 21-FEB-02:15 2464.98 12-JUN-17:15
Heating:EnergyTransfer:Zone:T N1 APARTMENT 1.06 0.00 01-JAN-00:15 1480.45 23-DEC-11:00
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 22.14 0.00 01-JAN-06:15 2464.98 12-JUN-17:15
EnergyTransfer:Zone:T N2 APARTMENT 23.21 0.01 05-MAR-01:00 2443.83 12-JUN-17:15
Heating:EnergyTransfer:Zone:T N2 APARTMENT 1.07 0.00 01-JAN-00:15 1477.49 23-DEC-11:00
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 22.15 0.00 01-JAN-06:15 2443.83 12-JUN-17:15
EnergyTransfer:Zone:T S1 APARTMENT 28.47 0.08 02-MAR-04:15 3261.31 02-DEC-13:00
Heating:EnergyTransfer:Zone:T S1 APARTMENT 0.50 0.00 01-JAN-00:15 1148.69 28-DEC-21:15
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 27.98 0.00 01-JAN-06:15 3261.31 02-DEC-13:00
EnergyTransfer:Zone:T S2 APARTMENT 28.49 0.03 05-MAR-06:00 3268.06 02-DEC-13:00
Heating:EnergyTransfer:Zone:T S2 APARTMENT 0.50 0.00 01-JAN-00:15 1151.93 28-DEC-21:15
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 27.99 0.00 01-JAN-06:15 3268.06 02-DEC-13:00
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Plant 687.76 362.54 24-JUL-01:15 127058.01 05-FEB-07:15
WaterSystems:EnergyTransfer 677.26 362.54 24-JUL-01:15 46848.14 24-JAN-07:15
sub cat:WaterSystems:EnergyTransfer 677.26 362.54 24-JUL-01:15 46848.14 24-JAN-07:15
EnergyTransfer:HVAC 3967.61 0.00 01-JAN-06:45 344274.85 10-AUG-20:15
CoolingCoils:EnergyTransfer 3932.83 0.00 01-JAN-06:15 344274.85 10-AUG-20:15
HeatingCoils:EnergyTransfer 34.78 0.00 01-JAN-00:15 107767.96 05-FEB-07:15
PlantLoopHeatingDemand:HVAC 26.76 0.00 01-JAN-00:15 82868.65 05-FEB-07:15
HeatingCoils:PlantLoopHeatingDemand 26.76 0.00 01-JAN-00:15 82868.65 05-FEB-07:15
Boilers:EnergyTransfer 10.49 0.00 01-JAN-00:15 80477.97 05-FEB-07:15



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 0.815 -20.709 0.000 0.000 3.629 2.413 12.213 23.105 0.000 0.684 0.000 0.000 -5.415 0.000 -4.066 -12.669
G NW APARTMENT 1.415 -16.259 0.000 0.000 3.663 2.413 12.213 14.478 0.000 0.681 0.000 0.000 -5.379 0.000 -3.517 -9.707
OFFICE 0.605 -26.527 0.000 0.000 0.504 21.954 7.547 23.057 0.000 0.318 0.000 0.000 -5.422 0.000 -0.802 -21.234
G NE APARTMENT 1.190 -16.390 0.000 0.000 3.673 2.413 12.213 14.500 0.000 0.680 0.000 0.000 -5.159 0.000 -3.492 -9.629
G N1 APARTMENT 0.471 -12.043 0.000 0.000 3.679 2.413 12.213 6.231 0.000 0.547 0.000 0.000 -3.252 0.000 -2.905 -7.354
G N2 APARTMENT 0.474 -12.050 0.000 0.000 3.679 2.413 12.213 6.229 0.000 0.546 0.000 0.000 -3.249 0.000 -2.903 -7.353
G S1 APARTMENT 0.118 -16.533 0.000 0.000 3.625 2.413 12.213 14.940 0.000 0.551 0.000 0.000 -3.275 0.000 -3.633 -10.419
G S2 APARTMENT 0.122 -16.782 0.000 0.000 3.623 2.413 12.213 14.929 0.000 0.552 0.000 0.000 -3.283 0.000 -3.657 -10.130
F2 SW APARTMENT 0.366 -31.445 0.000 0.000 3.571 2.413 12.213 22.095 0.000 0.879 1.130 0.000 -6.085 0.000 -5.136 -0.000
F2 NW APARTMENT 0.854 -24.466 0.000 0.000 3.616 2.413 12.213 13.737 0.000 0.873 1.380 0.000 -6.034 0.000 -4.586 -0.000
F2 SE APARTMENT 0.282 -32.896 0.000 0.000 3.570 2.413 12.213 22.167 0.000 0.875 2.586 0.000 -6.021 0.000 -5.189 -0.000
F2 NE APARTMENT 0.686 -24.688 0.000 0.000 3.625 2.413 12.213 13.732 0.000 0.872 1.480 0.000 -5.778 0.000 -4.555 -0.000
F2 N1 APARTMENT 0.171 -19.318 0.000 0.000 3.622 2.413 12.213 5.830 0.000 0.674 1.994 0.000 -3.717 0.000 -3.882 -0.000
F2 N2 APARTMENT 0.169 -19.321 0.000 0.000 3.622 2.413 12.213 5.828 0.000 0.673 1.995 0.000 -3.714 0.000 -3.880 -0.000
F2 S1 APARTMENT 0.041 -26.033 0.000 0.000 3.560 2.413 12.213 14.278 0.000 0.678 1.160 0.000 -3.692 0.000 -4.617 -0.000
F2 S2 APARTMENT 0.043 -26.148 0.000 0.000 3.559 2.413 12.213 14.276 0.000 0.679 1.284 0.000 -3.695 0.000 -4.623 -0.000
F3 SW APARTMENT 0.310 -33.078 0.000 0.000 3.563 2.413 12.213 21.644 0.000 1.028 3.745 0.000 -6.235 0.000 -5.602 -0.000
F3 NW APARTMENT 0.739 -25.947 0.000 0.000 3.607 2.413 12.213 13.440 0.000 1.022 3.800 0.000 -6.216 0.000 -5.069 0.000
F3 SE APARTMENT 0.229 -33.393 0.000 0.000 3.566 2.413 12.213 21.738 0.000 1.019 3.953 0.000 -6.125 0.000 -5.612 -0.000
F3 NE APARTMENT 0.591 -26.161 0.000 0.000 3.615 2.413 12.213 13.425 0.000 1.019 3.876 0.000 -5.952 0.000 -5.038 0.000
F3 N1 APARTMENT 0.123 -20.911 0.000 0.000 3.607 2.413 12.213 5.694 0.000 0.775 4.264 0.000 -3.859 0.000 -4.319 0.000
F3 N2 APARTMENT 0.123 -20.912 0.000 0.000 3.608 2.413 12.213 5.692 0.000 0.774 4.262 0.000 -3.856 0.000 -4.317 0.000
F3 S1 APARTMENT 0.030 -28.029 0.000 0.000 3.549 2.413 12.213 13.983 0.000 0.785 3.868 0.000 -3.793 0.000 -5.018 -0.000
F3 S2 APARTMENT 0.030 -28.062 0.000 0.000 3.549 2.413 12.213 13.982 0.000 0.785 3.903 0.000 -3.793 0.000 -5.020 -0.000
F4 SW APARTMENT 0.317 -33.241 0.000 0.000 3.563 2.413 12.213 21.341 0.000 1.113 4.490 0.000 -6.294 0.000 -5.915 -0.001
F4 NW APARTMENT 0.753 -26.239 0.000 0.000 3.606 2.413 12.213 13.254 0.000 1.106 4.566 0.000 -6.295 0.000 -5.376 0.000
F4 SE APARTMENT 0.236 -33.406 0.000 0.000 3.566 2.413 12.213 21.436 0.000 1.103 4.532 0.000 -6.175 0.000 -5.919 -0.000
F4 NE APARTMENT 0.605 -26.448 0.000 0.000 3.614 2.413 12.213 13.232 0.000 1.103 4.638 0.000 -6.026 0.000 -5.343 0.000
F4 N1 APARTMENT 0.126 -21.314 0.000 0.000 3.604 2.413 12.213 5.615 0.000 0.829 5.017 0.000 -3.923 0.000 -4.580 0.000
F4 N2 APARTMENT 0.125 -21.314 0.000 0.000 3.604 2.413 12.213 5.614 0.000 0.828 5.015 0.000 -3.920 0.000 -4.577 0.000
F4 S1 APARTMENT 0.031 -28.375 0.000 0.000 3.547 2.413 12.213 13.788 0.000 0.841 4.646 0.000 -3.833 0.000 -5.272 -0.000
F4 S2 APARTMENT 0.032 -28.391 0.000 0.000 3.548 2.413 12.213 13.787 0.000 0.842 4.662 0.000 -3.832 0.000 -5.273 -0.000
M SW APARTMENT 0.330 -33.695 0.000 0.000 3.563 2.413 12.213 21.091 0.000 1.180 5.444 0.000 -6.349 0.000 -6.189 -0.000
M NW APARTMENT 0.778 -26.801 0.000 0.000 3.606 2.413 12.213 13.098 0.000 1.172 5.527 0.000 -6.364 0.000 -5.642 0.000
M SE APARTMENT 0.250 -33.838 0.000 0.000 3.567 2.413 12.213 21.183 0.000 1.169 5.462 0.000 -6.227 0.000 -6.191 -0.000
M NE APARTMENT 0.629 -27.003 0.000 0.000 3.613 2.413 12.213 13.070 0.000 1.168 5.597 0.000 -6.091 0.000 -5.610 0.000
M N1 APARTMENT 0.136 -21.937 0.000 0.000 3.602 2.413 12.213 5.549 0.000 0.871 5.935 0.000 -3.976 0.000 -4.806 0.000
M N2 APARTMENT 0.135 -21.938 0.000 0.000 3.602 2.413 12.213 5.548 0.000 0.869 5.934 0.000 -3.973 0.000 -4.803 0.000
M S1 APARTMENT 0.036 -28.953 0.000 0.000 3.547 2.413 12.213 13.628 0.000 0.885 5.597 0.000 -3.869 0.000 -5.496 -0.000
M S2 APARTMENT 0.037 -28.966 0.000 0.000 3.547 2.413 12.213 13.627 0.000 0.886 5.608 0.000 -3.868 0.000 -5.497 -0.000
F6 SW APARTMENT 0.373 -32.581 0.000 0.000 3.568 2.413 12.213 20.920 0.000 1.253 4.546 0.000 -6.338 0.000 -6.366 -0.000
F6 NW APARTMENT 0.902 -25.963 0.000 0.000 3.612 2.413 12.213 13.011 0.000 1.245 4.695 0.000 -6.350 0.000 -5.777 0.000
F6 SE APARTMENT 0.288 -32.716 0.000 0.000 3.572 2.413 12.213 21.010 0.000 1.241 4.561 0.000 -6.214 0.000 -6.367 -0.000
F6 NE APARTMENT 0.744 -26.153 0.000 0.000 3.620 2.413 12.213 12.979 0.000 1.240 4.764 0.000 -6.075 0.000 -5.744 0.000
F6 N1 APARTMENT 0.182 -21.146 0.000 0.000 3.608 2.413 12.213 5.520 0.000 0.922 5.152 0.000 -3.968 0.000 -4.896 0.000
F6 N2 APARTMENT 0.181 -21.147 0.000 0.000 3.609 2.413 12.213 5.518 0.000 0.921 5.150 0.000 -3.965 0.000 -4.893 0.000
F6 S1 APARTMENT 0.042 -27.881 0.000 0.000 3.551 2.413 12.213 13.518 0.000 0.936 4.701 0.000 -3.864 0.000 -5.628 -0.000
F6 S2 APARTMENT 0.043 -27.894 0.000 0.000 3.551 2.413 12.213 13.517 0.000 0.937 4.712 0.000 -3.863 0.000 -5.629 -0.000
F7 SW APARTMENT 0.417 -32.013 0.000 0.000 3.572 2.413 12.213 20.762 0.000 1.307 4.212 0.000 -6.342 0.000 -6.540 -0.000
F7 NW APARTMENT 1.012 -25.603 0.000 0.000 3.617 2.413 12.213 12.924 0.000 1.298 4.400 0.000 -6.353 0.000 -5.920 0.000
F7 SE APARTMENT 0.331 -32.145 0.000 0.000 3.576 2.413 12.213 20.849 0.000 1.294 4.226 0.000 -6.216 0.000 -6.540 -0.000
F7 NE APARTMENT 0.850 -25.783 0.000 0.000 3.624 2.413 12.213 12.889 0.000 1.291 4.466 0.000 -6.077 0.000 -5.887 0.000
F7 N1 APARTMENT 0.229 -20.813 0.000 0.000 3.613 2.413 12.213 5.488 0.000 0.957 4.868 0.000 -3.970 0.000 -4.999 0.000
F7 N2 APARTMENT 0.228 -20.813 0.000 0.000 3.614 2.413 12.213 5.486 0.000 0.956 4.867 0.000 -3.967 0.000 -4.996 0.000
F7 S1 APARTMENT 0.050 -27.356 0.000 0.000 3.554 2.413 12.213 13.416 0.000 0.974 4.366 0.000 -3.866 0.000 -5.763 -0.000
F7 S2 APARTMENT 0.051 -27.368 0.000 0.000 3.555 2.413 12.213 13.415 0.000 0.974 4.376 0.000 -3.865 0.000 -5.764 -0.000
F8 SW APARTMENT 0.468 -31.709 0.000 0.000 3.575 2.413 12.213 20.617 0.000 1.357 4.128 0.000 -6.350 0.000 -6.712 -0.000
F8 NW APARTMENT 1.127 -25.485 0.000 0.000 3.620 2.413 12.213 12.842 0.000 1.347 4.355 0.000 -6.363 0.000 -6.069 0.000
F8 SE APARTMENT 0.379 -31.837 0.000 0.000 3.579 2.413 12.213 20.702 0.000 1.344 4.142 0.000 -6.222 0.000 -6.711 -0.001
F8 NE APARTMENT 0.961 -25.657 0.000 0.000 3.628 2.413 12.213 12.804 0.000 1.340 4.417 0.000 -6.085 0.000 -6.033 0.000
F8 N1 APARTMENT 0.283 -20.704 0.000 0.000 3.617 2.413 12.213 5.456 0.000 0.990 4.820 0.000 -3.976 0.000 -5.111 0.000
F8 N2 APARTMENT 0.282 -20.703 0.000 0.000 3.618 2.413 12.213 5.454 0.000 0.988 4.817 0.000 -3.973 0.000 -5.108 0.000
F8 S1 APARTMENT 0.061 -27.081 0.000 0.000 3.558 2.413 12.213 13.324 0.000 1.009 4.274 0.000 -3.871 0.000 -5.899 -0.000
F8 S2 APARTMENT 0.062 -27.093 0.000 0.000 3.558 2.413 12.213 13.323 0.000 1.010 4.284 0.000 -3.870 0.000 -5.900 -0.000
F9 SW APARTMENT 0.582 -31.942 0.000 0.000 3.580 2.413 12.213 20.486 0.000 1.400 4.476 0.000 -6.355 0.000 -6.854 -0.000
F9 NW APARTMENT 1.353 -25.953 0.000 0.000 3.624 2.413 12.213 12.760 0.000 1.390 4.775 0.000 -6.377 0.000 -6.199 0.000
F9 SE APARTMENT 0.474 -32.065 0.000 0.000 3.584 2.413 12.213 20.568 0.000 1.386 4.504 0.000 -6.224 0.000 -6.853 -0.000
F9 NE APARTMENT 1.155 -26.115 0.000 0.000 3.632 2.413 12.213 12.721 0.000 1.381 4.853 0.000 -6.095 0.000 -6.159 0.000
F9 N1 APARTMENT 0.390 -21.116 0.000 0.000 3.622 2.413 12.213 5.423 0.000 1.024 5.220 0.000 -3.981 0.000 -5.209 0.000
F9 N2 APARTMENT 0.389 -21.116 0.000 0.000 3.622 2.413 12.213 5.422 0.000 1.023 5.218 0.000 -3.977 0.000 -5.206 0.000
F9 S1 APARTMENT 0.090 -27.280 0.000 0.000 3.563 2.413 12.213 13.243 0.000 1.043 4.593 0.000 -3.871 0.000 -6.006 -0.000
F9 S2 APARTMENT 0.092 -27.293 0.000 0.000 3.563 2.413 12.213 13.242 0.000 1.044 4.603 0.000 -3.870 0.000 -6.006 -0.000
T SW APARTMENT 1.714 -32.854 0.000 0.000 3.607 2.413 12.213 20.105 0.000 1.433 4.288 0.000 -6.065 0.000 -6.854 -0.000
T NW APARTMENT 2.737 -27.131 0.000 0.000 3.639 2.413 12.213 12.431 0.000 1.421 4.723 0.000 -6.147 0.000 -6.299 -0.000
T SE APARTMENT 1.481 -32.807 0.000 0.000 3.613 2.413 12.213 20.194 0.000 1.423 4.276 0.000 -5.943 0.000 -6.863 -0.000
T NE APARTMENT 2.332 -27.093 0.000 0.000 3.649 2.413 12.213 12.424 0.000 1.419 4.795 0.000 -5.891 0.000 -6.260 -0.000
T N1 APARTMENT 1.063 -22.139 0.000 0.000 3.640 2.413 12.213 5.304 0.000 1.083 5.514 0.000 -3.821 0.000 -5.270 -0.000
T N2 APARTMENT 1.065 -22.147 0.000 0.000 3.641 2.413 12.213 5.302 0.000 1.083 5.516 0.000 -3.816 0.000 -5.270 -0.000
T S1 APARTMENT 0.498 -27.974 0.000 0.000 3.594 2.413 12.213 13.044 0.000 1.095 4.817 0.000 -3.717 0.000 -5.983 -0.000
T S2 APARTMENT 0.502 -27.990 0.000 0.000 3.594 2.413 12.213 13.042 0.000 1.095 4.829 0.000 -3.714 0.000 -5.985 -0.000
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 5.206 0.000 5.514 0.000 0.000 -1.283 0.000 -15.818 -12.148
F2 CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 2.407 0.000 0.037 0.000 0.000 -0.856 0.000 -0.249 -19.869
F3 CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 2.331 0.000 0.041 0.000 0.000 -0.900 0.000 -0.310 -19.692
F4 CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 2.281 0.000 0.044 0.000 0.000 -0.924 0.000 -0.354 -19.577
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 37.059 0.000 2.202 0.000 0.038 0.000 0.000 -0.987 0.000 -0.421 -37.890
F6 CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 2.231 0.000 0.051 0.000 0.000 -0.933 0.000 -0.410 -19.468
F7 CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 2.222 0.000 0.055 0.000 0.000 -0.924 0.000 -0.427 -19.455
F8 CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 2.206 0.000 0.057 0.000 0.000 -0.924 0.000 -0.446 -19.423
F9 CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 0.000 2.188 0.000 0.057 0.000 0.000 -0.930 0.000 -0.464 -19.380
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 18.529 7.937 2.069 0.000 0.032 0.000 0.000 -0.929 0.000 -0.519 -27.120
Total Facility 40.013 -2070.621 0.000 0.000 284.716 416.414 980.287 1100.665 0.000 86.738 313.649 0.000 -405.468 0.000 -443.877 -302.525


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 30-AUG-15:30 0.00 -3090.16 0.00 0.00 48.79 100.83 470.89 3724.75 0.00 45.77 0.00 0.00 0.00 0.00 0.00 -1300.87
G NW APARTMENT 12-JUN-17:10 0.00 -2837.54 0.00 0.00 141.82 194.45 588.62 2899.56 0.00 22.12 0.00 0.00 0.00 0.00 0.00 -1009.04
OFFICE 01-SEP-11:00 0.00 -3438.94 0.00 0.00 65.20 1622.33 544.91 3064.95 0.00 19.44 0.00 0.00 0.00 0.00 0.00 -1877.90
G NE APARTMENT 28-JUN-10:30 0.00 -2136.78 0.00 0.00 40.52 28.81 412.03 2401.51 0.00 22.84 0.00 0.00 0.00 0.00 0.00 -768.93
G N1 APARTMENT 12-JUN-17:15 0.00 -1418.94 0.00 0.00 141.82 194.45 588.62 940.86 0.00 13.23 0.00 0.00 0.00 0.00 0.00 -460.05
G N2 APARTMENT 12-JUN-17:15 0.00 -1407.04 0.00 0.00 141.82 194.45 588.62 941.08 0.00 13.23 0.00 0.00 0.00 0.00 0.00 -472.17
G S1 APARTMENT 01-JAN-14:00 0.00 -2053.48 0.00 0.00 40.59 28.81 388.49 3200.35 0.00 115.73 0.00 0.00 0.00 0.00 0.00 -1720.48
G S2 APARTMENT 01-JAN-14:00 0.00 -2100.00 0.00 0.00 40.74 28.81 388.49 3201.68 0.00 122.44 0.00 0.00 0.00 0.00 0.00 -1682.15
F2 SW APARTMENT 06-NOV-15:15 0.00 -3788.04 0.00 0.00 40.75 50.41 400.26 4098.79 0.00 17.85 0.00 0.00 0.00 0.00 0.00 -820.02
F2 NW APARTMENT 12-JUN-17:10 0.00 -3316.54 0.00 0.00 141.82 194.45 588.62 2873.58 0.00 31.71 0.00 0.00 0.00 0.00 0.00 -513.64
F2 SE APARTMENT 06-NOV-13:30 0.00 -3378.05 0.00 0.00 40.55 28.81 388.49 3432.17 0.00 5.10 0.00 0.00 0.00 0.00 0.00 -517.07
F2 NE APARTMENT 13-JUN-09:45 0.00 -2576.58 0.00 0.00 40.52 28.81 406.15 2401.46 0.00 47.08 0.00 0.00 0.00 0.00 0.00 -347.43
F2 N1 APARTMENT 12-JUN-17:10 0.00 -1752.34 0.00 0.00 141.82 194.45 588.62 926.57 0.00 19.03 0.00 0.00 0.00 0.00 0.00 -118.15
F2 N2 APARTMENT 12-JUN-17:10 0.00 -1743.00 0.00 0.00 141.82 194.45 588.62 926.69 0.00 19.03 0.00 0.00 0.00 0.00 0.00 -127.61
F2 S1 APARTMENT 02-DEC-13:15 0.00 -2598.11 0.00 0.00 40.29 28.81 388.49 3231.81 0.00 25.31 0.00 0.00 0.00 0.00 0.00 -1116.59
F2 S2 APARTMENT 02-DEC-13:15 0.00 -2617.27 0.00 0.00 40.32 28.81 388.49 3231.98 0.00 26.23 0.00 0.00 0.00 0.00 0.00 -1098.56
F3 SW APARTMENT 06-NOV-15:30 0.00 -3833.05 0.00 0.00 40.55 50.41 400.26 3968.56 0.00 20.70 0.00 0.00 0.00 0.00 0.00 -647.42
F3 NW APARTMENT 12-JUN-17:10 0.00 -3335.24 0.00 0.00 141.82 194.45 588.62 2859.20 0.00 37.44 0.00 0.00 0.00 0.00 0.00 -486.28
F3 SE APARTMENT 10-DEC-13:45 0.00 -3345.34 0.00 0.00 40.50 28.81 388.49 3368.52 0.00 23.77 0.00 0.00 0.00 0.00 0.00 -504.74
F3 NE APARTMENT 13-JUN-09:45 0.00 -2584.62 0.00 0.00 40.37 28.81 406.15 2366.40 0.00 55.07 0.00 0.00 0.00 0.00 0.00 -312.17
F3 N1 APARTMENT 12-JUN-17:10 0.00 -1785.63 0.00 0.00 141.82 194.45 588.62 920.99 0.00 22.48 0.00 0.00 0.00 0.00 0.00 -82.73
F3 N2 APARTMENT 12-JUN-17:10 0.00 -1776.31 0.00 0.00 141.82 194.45 588.62 921.12 0.00 22.47 0.00 0.00 0.00 0.00 0.00 -92.17
F3 S1 APARTMENT 02-DEC-13:00 0.00 -2641.75 0.00 0.00 40.08 28.81 406.15 3279.39 0.00 15.96 0.00 0.00 0.00 0.00 0.00 -1128.64
F3 S2 APARTMENT 02-DEC-13:00 0.00 -2650.73 0.00 0.00 40.09 28.81 406.15 3279.40 0.00 16.27 0.00 0.00 0.00 0.00 0.00 -1119.98
F4 SW APARTMENT 06-NOV-15:30 0.00 -3844.97 0.00 0.00 40.54 50.41 400.26 3949.27 0.00 22.99 0.00 0.00 0.00 0.00 0.00 -618.50
F4 NW APARTMENT 12-JUN-17:10 0.00 -3342.22 0.00 0.00 141.82 194.45 588.62 2847.60 0.00 41.72 0.00 0.00 0.00 0.00 0.00 -472.00
F4 SE APARTMENT 01-JAN-14:00 0.00 -3351.10 0.00 0.00 40.76 28.81 388.49 3364.39 0.00 136.07 0.00 0.00 0.00 0.00 0.00 -607.41
F4 NE APARTMENT 08-JUL-11:00 0.00 -2597.48 0.00 0.00 40.50 28.81 412.03 2292.11 0.00 33.33 0.00 0.00 0.00 0.00 0.00 -209.31
F4 N1 APARTMENT 12-JUN-17:10 0.00 -1806.40 0.00 0.00 141.82 194.45 588.62 916.70 0.00 25.08 0.00 0.00 0.00 0.00 0.00 -60.27
F4 N2 APARTMENT 12-JUN-17:10 0.00 -1797.14 0.00 0.00 141.82 194.45 588.62 916.83 0.00 25.07 0.00 0.00 0.00 0.00 0.00 -69.65
F4 S1 APARTMENT 02-DEC-13:00 0.00 -2655.41 0.00 0.00 40.08 28.81 406.15 3255.48 0.00 15.38 0.00 0.00 0.00 0.00 0.00 -1090.48
F4 S2 APARTMENT 02-DEC-13:00 0.00 -2662.78 0.00 0.00 40.09 28.81 406.15 3255.49 0.00 15.66 0.00 0.00 0.00 0.00 0.00 -1083.41
M SW APARTMENT 06-NOV-15:30 0.00 -3879.01 0.00 0.00 40.58 50.41 400.26 3933.04 0.00 24.95 0.00 0.00 0.00 0.00 0.00 -570.23
M NW APARTMENT 12-JUN-17:10 0.00 -3370.95 0.00 0.00 141.82 194.45 588.62 2836.93 0.00 45.22 0.00 0.00 0.00 0.00 0.00 -436.08
M SE APARTMENT 01-JAN-14:00 0.00 -3367.24 0.00 0.00 40.76 28.81 388.49 3349.87 0.00 137.17 0.00 0.00 0.00 0.00 0.00 -577.85
M NE APARTMENT 13-JUN-09:45 0.00 -2627.61 0.00 0.00 40.43 28.81 406.15 2322.13 0.00 66.67 0.00 0.00 0.00 0.00 0.00 -236.57
M N1 APARTMENT 12-JUN-17:10 0.00 -1849.08 0.00 0.00 141.82 194.45 588.62 912.61 0.00 27.21 0.00 0.00 0.00 0.00 0.00 -15.62
M N2 APARTMENT 12-JUN-17:10 0.00 -1839.87 0.00 0.00 141.82 194.45 588.62 912.74 0.00 27.20 0.00 0.00 0.00 0.00 0.00 -24.96
M S1 APARTMENT 02-DEC-13:00 0.00 -2689.52 0.00 0.00 40.15 28.81 406.15 3235.81 0.00 16.76 0.00 0.00 0.00 0.00 0.00 -1038.14
M S2 APARTMENT 02-DEC-13:00 0.00 -2696.62 0.00 0.00 40.15 28.81 406.15 3235.82 0.00 17.04 0.00 0.00 0.00 0.00 0.00 -1031.35
F6 SW APARTMENT 06-NOV-15:30 0.00 -3839.22 0.00 0.00 40.61 50.41 400.26 3920.26 0.00 26.59 0.00 0.00 0.00 0.00 0.00 -598.91
F6 NW APARTMENT 12-JUN-17:10 0.00 -3331.83 0.00 0.00 141.82 194.45 588.62 2829.11 0.00 48.19 0.00 0.00 0.00 0.00 0.00 -470.35
F6 SE APARTMENT 06-NOV-14:15 0.00 -3321.07 0.00 0.00 40.36 28.81 382.60 3075.82 0.00 19.77 0.00 0.00 0.00 0.00 0.00 -226.30
F6 NE APARTMENT 13-JUN-09:45 0.00 -2590.38 0.00 0.00 40.44 28.81 406.15 2306.21 0.00 71.07 0.00 0.00 0.00 0.00 0.00 -262.29
F6 N1 APARTMENT 12-JUN-17:05 0.00 -1819.38 0.00 0.00 141.82 194.45 588.62 910.10 0.00 29.04 0.00 0.00 0.00 0.00 0.00 -44.66
F6 N2 APARTMENT 12-JUN-17:10 0.00 -1810.27 0.00 0.00 141.82 194.45 588.62 910.23 0.00 29.01 0.00 0.00 0.00 0.00 0.00 -53.86
F6 S1 APARTMENT 02-DEC-13:00 0.00 -2649.69 0.00 0.00 40.20 28.81 406.15 3219.67 0.00 17.51 0.00 0.00 0.00 0.00 0.00 -1062.64
F6 S2 APARTMENT 02-DEC-13:00 0.00 -2656.74 0.00 0.00 40.21 28.81 406.15 3219.69 0.00 17.82 0.00 0.00 0.00 0.00 0.00 -1055.93
F7 SW APARTMENT 06-NOV-15:30 0.00 -3825.50 0.00 0.00 40.64 50.41 400.26 3908.20 0.00 28.05 0.00 0.00 0.00 0.00 0.00 -602.06
F7 NW APARTMENT 12-JUN-17:10 0.00 -3317.61 0.00 0.00 141.82 194.45 588.62 2821.36 0.00 50.78 0.00 0.00 0.00 0.00 0.00 -479.42
F7 SE APARTMENT 06-NOV-14:15 0.00 -3310.77 0.00 0.00 40.40 28.81 382.60 3070.03 0.00 20.87 0.00 0.00 0.00 0.00 0.00 -231.94
F7 NE APARTMENT 13-JUN-09:45 0.00 -2579.22 0.00 0.00 40.46 28.81 406.15 2291.33 0.00 74.95 0.00 0.00 0.00 0.00 0.00 -262.47
F7 N1 APARTMENT 12-JUN-17:05 0.00 -1815.08 0.00 0.00 141.82 194.45 588.62 907.42 0.00 30.62 0.00 0.00 0.00 0.00 0.00 -47.85
F7 N2 APARTMENT 12-JUN-17:05 0.00 -1805.99 0.00 0.00 141.82 194.45 588.62 907.55 0.00 30.62 0.00 0.00 0.00 0.00 0.00 -57.06
F7 S1 APARTMENT 02-DEC-13:00 0.00 -2635.78 0.00 0.00 40.27 28.81 406.15 3204.97 0.00 18.67 0.00 0.00 0.00 0.00 0.00 -1063.09
F7 S2 APARTMENT 02-DEC-13:00 0.00 -2642.78 0.00 0.00 40.28 28.81 406.15 3205.00 0.00 19.00 0.00 0.00 0.00 0.00 0.00 -1056.45
F8 SW APARTMENT 06-NOV-15:30 0.00 -3825.21 0.00 0.00 40.70 50.41 400.26 3897.32 0.00 29.41 0.00 0.00 0.00 0.00 0.00 -592.90
F8 NW APARTMENT 12-JUN-17:10 0.00 -3317.46 0.00 0.00 141.82 194.45 588.62 2813.78 0.00 53.10 0.00 0.00 0.00 0.00 0.00 -474.31
F8 SE APARTMENT 06-NOV-14:15 0.00 -3314.58 0.00 0.00 40.47 28.81 382.60 3064.96 0.00 21.91 0.00 0.00 0.00 0.00 0.00 -224.18
F8 NE APARTMENT 28-JUN-10:30 0.00 -2581.76 0.00 0.00 40.60 28.81 412.03 2318.35 0.00 54.90 0.00 0.00 0.00 0.00 0.00 -272.93
F8 N1 APARTMENT 12-JUN-17:05 0.00 -1825.78 0.00 0.00 141.82 194.45 588.62 904.67 0.00 32.03 0.00 0.00 0.00 0.00 0.00 -35.81
F8 N2 APARTMENT 12-JUN-17:05 0.00 -1816.77 0.00 0.00 141.82 194.45 588.62 904.80 0.00 32.03 0.00 0.00 0.00 0.00 0.00 -44.95
F8 S1 APARTMENT 02-DEC-13:00 0.00 -2635.81 0.00 0.00 40.37 28.81 406.15 3192.03 0.00 21.13 0.00 0.00 0.00 0.00 0.00 -1052.68
F8 S2 APARTMENT 02-DEC-13:00 0.00 -2642.78 0.00 0.00 40.38 28.81 406.15 3192.06 0.00 21.49 0.00 0.00 0.00 0.00 0.00 -1046.10
F9 SW APARTMENT 06-NOV-15:15 0.00 -3863.78 0.00 0.00 40.75 50.41 400.26 3984.99 0.00 30.53 0.00 0.00 0.00 0.00 0.00 -643.16
F9 NW APARTMENT 12-JUN-17:10 0.00 -3403.33 0.00 0.00 141.82 194.45 588.62 2803.82 0.00 55.20 0.00 0.00 0.00 0.00 0.00 -380.57
F9 SE APARTMENT 06-NOV-14:00 0.00 -3349.28 0.00 0.00 40.43 28.81 388.49 3183.76 0.00 20.05 0.00 0.00 0.00 0.00 0.00 -312.25
F9 NE APARTMENT 28-JUN-10:30 0.00 -2620.83 0.00 0.00 40.65 28.81 412.03 2311.18 0.00 57.15 0.00 0.00 0.00 0.00 0.00 -229.00
F9 N1 APARTMENT 12-JUN-17:10 0.00 -1905.04 0.00 0.00 141.82 194.45 588.62 900.42 0.00 33.29 46.45 0.00 0.00 0.00 0.00 0.00
F9 N2 APARTMENT 12-JUN-17:10 0.00 -1897.30 0.00 0.00 141.82 194.45 588.62 900.54 0.00 33.29 38.58 0.00 0.00 0.00 0.00 0.00
F9 S1 APARTMENT 02-DEC-13:15 0.00 -2680.80 0.00 0.00 40.50 28.81 388.49 3085.08 0.00 32.61 0.00 0.00 0.00 0.00 0.00 -894.68
F9 S2 APARTMENT 02-DEC-13:15 0.00 -2688.28 0.00 0.00 40.51 28.81 388.49 3085.13 0.00 33.11 0.00 0.00 0.00 0.00 0.00 -887.77
T SW APARTMENT 06-NOV-14:30 0.00 -4560.21 0.00 0.00 40.75 28.81 382.60 4132.70 0.00 26.27 0.00 0.00 0.00 0.00 0.00 -50.92
T NW APARTMENT 12-JUN-16:30 0.00 -4135.12 0.00 0.00 84.76 144.04 588.62 3075.43 0.00 45.26 197.01 0.00 0.00 0.00 0.00 0.00
T SE APARTMENT 06-NOV-14:15 0.00 -3968.54 0.00 0.00 40.28 28.81 382.60 3008.31 0.00 23.16 485.37 0.00 0.00 0.00 0.00 0.00
T NE APARTMENT 08-JUL-11:30 0.00 -3218.18 0.00 0.00 40.51 28.81 406.15 1998.98 0.00 48.62 695.11 0.00 0.00 0.00 0.00 0.00
T N1 APARTMENT 12-JUN-17:10 0.00 -2466.09 0.00 0.00 141.82 194.45 588.62 880.97 0.00 34.45 625.79 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 12-JUN-17:10 0.00 -2444.93 0.00 0.00 141.82 194.45 588.62 881.40 0.00 34.45 604.19 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 02-DEC-13:00 0.00 -3260.84 0.00 0.00 40.75 28.81 406.15 3153.41 0.00 41.69 0.00 0.00 0.00 0.00 0.00 -409.97
T S2 APARTMENT 02-DEC-13:00 0.00 -3267.59 0.00 0.00 40.75 28.81 406.15 3153.26 0.00 41.69 0.00 0.00 0.00 0.00 0.00 -403.06
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 30-AUG-16:10 0.00 -191377.84 0.00 0.00 6689.93 18221.75 47207.76 125476.21 0.00 11310.29 0.00 0.00 0.00 0.00 0.00 -17528.10


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 20-DEC-07:30 1067.14 0.00 0.00 0.00 161.22 93.62 382.60 0.00 0.00 0.00 405.37 0.00 -1915.56 0.00 -194.40 0.00
G NW APARTMENT 05-FEB-08:15 1252.39 0.00 0.00 0.00 73.97 43.21 388.49 0.00 0.00 0.00 0.00 0.00 -1220.88 0.00 -300.44 -236.75
OFFICE 05-FEB-07:15 1273.85 0.00 0.00 0.00 0.00 379.58 128.69 0.00 0.00 0.00 17.97 0.00 -1513.02 0.00 -287.07 0.00
G NE APARTMENT 21-DEC-15:40 1193.76 0.00 0.00 0.00 46.48 50.41 400.26 72.32 0.00 0.00 0.00 0.00 0.00 0.00 -1016.69 -746.54
G N1 APARTMENT 28-OCT-10:15 1167.33 0.00 0.00 0.00 44.25 28.81 412.03 155.96 0.00 0.00 0.00 0.00 0.00 0.00 -1215.79 -592.60
G N2 APARTMENT 28-OCT-10:15 1192.35 0.00 0.00 0.00 44.22 28.81 412.03 155.45 0.00 0.00 0.00 0.00 0.00 0.00 -1215.65 -617.22
G S1 APARTMENT 16-FEB-06:15 716.98 0.00 0.00 0.00 177.43 100.83 317.85 0.00 0.00 0.00 0.00 0.00 -384.74 0.00 -927.19 -1.16
G S2 APARTMENT 10-MAR-12:20 662.60 0.00 0.00 0.00 47.36 28.81 406.15 247.34 0.00 0.00 0.00 0.00 0.00 0.00 -1026.82 -365.44
F2 SW APARTMENT 05-FEB-07:15 871.38 0.00 0.00 0.00 161.22 93.62 382.60 0.00 0.00 0.00 485.93 0.00 -1581.89 0.00 -412.87 0.00
F2 NW APARTMENT 10-MAR-12:15 1038.93 0.00 0.00 0.00 44.47 28.81 406.15 297.28 0.00 0.00 0.00 0.00 0.00 0.00 -1383.16 -432.48
F2 SE APARTMENT 05-FEB-07:15 877.58 0.00 0.00 0.00 161.22 93.62 382.60 0.00 0.00 0.00 479.13 0.00 -1581.29 0.00 -412.87 0.00
F2 NE APARTMENT 10-MAR-12:15 1146.75 0.00 0.00 0.00 44.47 28.81 406.15 310.37 0.00 0.00 0.00 0.00 0.00 0.00 -1378.25 -558.30
F2 N1 APARTMENT 10-MAR-12:15 1141.29 0.00 0.00 0.00 44.60 28.81 406.15 174.34 0.00 0.00 0.00 0.00 0.00 0.00 -1333.72 -461.47
F2 N2 APARTMENT 10-MAR-12:15 1139.54 0.00 0.00 0.00 44.61 28.81 406.15 174.42 0.00 0.00 0.00 0.00 0.00 0.00 -1333.68 -459.85
F2 S1 APARTMENT 05-FEB-04:15 511.56 0.00 0.00 0.00 189.67 43.21 223.68 0.00 0.00 0.00 117.91 0.00 -893.32 0.00 -192.70 0.00
F2 S2 APARTMENT 16-FEB-06:20 140.79 0.00 0.00 0.00 185.89 100.83 317.85 0.00 0.00 0.00 918.20 0.00 -420.80 0.00 -1242.76 0.00
F3 SW APARTMENT 05-FEB-07:15 859.24 0.00 0.00 0.00 161.22 93.62 382.60 0.00 0.00 0.00 606.97 0.00 -1614.56 0.00 -489.10 0.00
F3 NW APARTMENT 10-MAR-12:15 1180.51 0.00 0.00 0.00 44.13 28.81 406.15 261.60 0.00 0.00 0.00 0.00 0.00 0.00 -1516.51 -404.68
F3 SE APARTMENT 05-FEB-07:15 875.00 0.00 0.00 0.00 161.22 93.62 382.60 0.00 0.00 0.00 590.32 0.00 -1613.67 0.00 -489.10 0.00
F3 NE APARTMENT 10-MAR-12:15 1294.29 0.00 0.00 0.00 44.14 28.81 406.15 270.22 0.00 0.00 0.00 0.00 0.00 0.00 -1511.32 -532.29
F3 N1 APARTMENT 10-MAR-12:15 1333.91 0.00 0.00 0.00 44.01 28.81 406.15 147.36 0.00 0.00 0.00 0.00 0.00 0.00 -1459.78 -500.45
F3 N2 APARTMENT 10-MAR-12:15 1332.04 0.00 0.00 0.00 44.02 28.81 406.15 147.44 0.00 0.00 0.00 0.00 0.00 0.00 -1459.74 -498.71
F3 S1 APARTMENT 16-FEB-06:20 145.26 0.00 0.00 0.00 185.52 100.83 317.85 0.00 0.00 0.00 1031.64 0.00 -431.55 0.00 -1349.55 0.00
F3 S2 APARTMENT 16-FEB-06:20 146.66 0.00 0.00 0.00 185.49 100.83 317.85 0.00 0.00 0.00 1030.95 0.00 -431.57 0.00 -1350.21 0.00
F4 SW APARTMENT 05-FEB-07:15 909.05 0.00 0.00 0.00 161.22 93.62 382.60 0.00 0.00 0.00 635.01 0.00 -1634.50 0.00 -547.01 0.00
F4 NW APARTMENT 10-MAR-12:15 1381.74 0.00 0.00 0.00 44.14 28.81 406.15 243.08 0.00 0.00 0.00 0.00 0.00 0.00 -1619.98 -483.94
F4 SE APARTMENT 05-FEB-07:15 928.43 0.00 0.00 0.00 161.22 93.62 382.60 0.00 0.00 0.00 614.55 0.00 -1633.41 0.00 -547.01 0.00
F4 NE APARTMENT 10-MAR-12:15 1372.18 0.00 0.00 0.00 44.18 28.81 406.15 248.80 0.00 0.00 0.00 0.00 0.00 0.00 -1618.42 -481.69
F4 N1 APARTMENT 07-DEC-10:00 1451.43 0.00 0.00 0.00 43.08 28.81 394.37 0.00 0.00 0.00 0.00 0.00 -32.93 0.00 -1566.08 -318.68
F4 N2 APARTMENT 07-DEC-10:00 1450.33 0.00 0.00 0.00 43.13 28.81 394.37 0.00 0.00 0.00 0.00 0.00 -32.18 0.00 -1565.50 -318.95
F4 S1 APARTMENT 16-FEB-06:20 152.99 0.00 0.00 0.00 186.35 100.83 317.85 0.00 0.00 0.00 1076.47 0.00 -431.69 0.00 -1402.80 0.00
F4 S2 APARTMENT 16-FEB-06:20 154.13 0.00 0.00 0.00 186.35 100.83 317.85 0.00 0.00 0.00 1074.55 0.00 -431.38 0.00 -1402.33 0.00
M SW APARTMENT 05-FEB-07:15 957.30 0.00 0.00 0.00 161.22 93.62 382.60 0.00 0.00 0.00 649.95 0.00 -1649.87 0.00 -594.82 0.00
M NW APARTMENT 07-DEC-10:00 1599.75 0.00 0.00 0.00 43.38 28.81 394.37 0.00 0.00 0.00 0.00 0.00 -44.33 0.00 -1731.54 -290.43
M SE APARTMENT 05-FEB-07:15 977.64 0.00 0.00 0.00 161.22 93.62 382.60 0.00 0.00 0.00 628.47 0.00 -1648.74 0.00 -594.82 0.00
M NE APARTMENT 10-MAR-12:15 1405.75 0.00 0.00 0.00 44.23 28.81 406.15 233.63 0.00 0.00 0.00 0.00 0.00 0.00 -1711.82 -406.75
M N1 APARTMENT 07-DEC-10:00 1477.70 0.00 0.00 0.00 42.97 28.81 394.37 0.00 0.00 0.00 0.00 0.00 -43.11 0.00 -1663.60 -237.14
M N2 APARTMENT 07-DEC-10:00 1506.43 0.00 0.00 0.00 43.03 28.81 394.37 0.00 0.00 0.00 0.00 0.00 -42.33 0.00 -1662.60 -267.71
M S1 APARTMENT 16-FEB-06:20 160.22 0.00 0.00 0.00 186.56 100.83 317.85 0.00 0.00 0.00 1127.72 0.00 -432.52 0.00 -1460.66 0.00
M S2 APARTMENT 16-FEB-06:20 161.35 0.00 0.00 0.00 186.57 100.83 317.85 0.00 0.00 0.00 1125.44 0.00 -432.15 0.00 -1459.90 0.00
F6 SW APARTMENT 05-FEB-07:15 1057.93 0.00 0.00 0.00 161.22 93.62 382.60 0.00 0.00 0.00 600.34 0.00 -1659.63 0.00 -636.09 0.00
F6 NW APARTMENT 23-DEC-10:55 1803.80 0.00 0.00 0.00 46.07 28.81 406.15 72.81 0.00 0.00 0.00 0.00 0.00 0.00 -1760.99 -596.65
F6 SE APARTMENT 05-FEB-07:15 1076.28 0.00 0.00 0.00 161.22 93.62 382.60 0.00 0.00 0.00 580.87 0.00 -1658.50 0.00 -636.09 0.00
F6 NE APARTMENT 10-MAR-12:30 1411.95 0.00 0.00 0.00 44.53 28.81 406.15 180.41 0.00 0.00 0.00 0.00 0.00 0.00 -1770.50 -301.35
F6 N1 APARTMENT 23-DEC-10:55 1814.75 0.00 0.00 0.00 45.72 28.81 406.15 27.67 0.00 0.00 0.00 0.00 0.00 0.00 -1691.01 -632.09
F6 N2 APARTMENT 23-DEC-10:55 1830.76 0.00 0.00 0.00 45.72 28.81 406.15 27.64 0.00 0.00 0.00 0.00 0.00 0.00 -1690.78 -648.30
F6 S1 APARTMENT 16-FEB-06:20 229.53 0.00 0.00 0.00 188.44 100.83 317.85 0.00 0.00 0.00 1052.26 0.00 -423.31 0.00 -1465.60 0.00
F6 S2 APARTMENT 16-FEB-06:20 237.17 0.00 0.00 0.00 188.45 100.83 317.85 0.00 0.00 0.00 1044.23 0.00 -422.96 0.00 -1465.57 0.00
F7 SW APARTMENT 05-FEB-07:15 1136.31 0.00 0.00 0.00 161.22 93.62 382.60 0.00 0.00 0.00 567.34 0.00 -1668.38 0.00 -672.72 0.00
F7 NW APARTMENT 23-DEC-10:55 1830.42 0.00 0.00 0.00 46.29 28.81 406.15 69.22 0.00 0.00 0.00 0.00 0.00 0.00 -1839.61 -541.28
F7 SE APARTMENT 05-FEB-07:15 1152.06 0.00 0.00 0.00 161.22 93.62 382.60 0.00 0.00 0.00 550.51 0.00 -1667.30 0.00 -672.72 0.00
F7 NE APARTMENT 10-MAR-12:30 1411.02 0.00 0.00 0.00 44.79 28.81 406.15 174.84 0.00 0.00 0.00 0.00 0.00 0.00 -1846.94 -218.66
F7 N1 APARTMENT 23-DEC-10:55 1933.20 0.00 0.00 0.00 45.93 28.81 406.15 24.71 0.00 0.00 0.00 0.00 0.00 0.00 -1762.96 -675.84
F7 N2 APARTMENT 23-DEC-10:55 1933.17 0.00 0.00 0.00 45.93 28.81 406.15 24.67 0.00 0.00 0.00 0.00 0.00 0.00 -1762.94 -675.79
F7 S1 APARTMENT 16-FEB-06:20 455.74 0.00 0.00 0.00 189.20 100.83 317.85 0.00 0.00 0.00 867.04 0.00 -418.41 0.00 -1512.25 0.00
F7 S2 APARTMENT 16-FEB-06:20 462.91 0.00 0.00 0.00 189.20 100.83 317.85 0.00 0.00 0.00 859.48 0.00 -418.05 0.00 -1512.22 0.00
F8 SW APARTMENT 05-FEB-07:15 1209.51 0.00 0.00 0.00 161.22 93.62 382.60 0.00 0.00 0.00 534.51 0.00 -1675.61 0.00 -705.86 0.00
F8 NW APARTMENT 23-DEC-10:55 1835.93 0.00 0.00 0.00 46.45 28.81 406.15 65.46 0.00 0.00 0.00 0.00 0.00 0.00 -1912.48 -470.31
F8 SE APARTMENT 05-FEB-07:15 1222.07 0.00 0.00 0.00 161.22 93.62 382.60 0.00 0.00 0.00 520.86 0.00 -1674.52 0.00 -705.86 0.00
F8 NE APARTMENT 10-MAR-12:25 1656.07 0.00 0.00 0.00 45.04 28.81 406.15 170.63 0.00 0.00 0.00 0.00 0.00 0.00 -1940.54 -366.15
F8 N1 APARTMENT 23-DEC-10:55 1944.76 0.00 0.00 0.00 46.08 28.81 406.15 21.73 0.00 0.00 0.00 0.00 0.00 0.00 -1832.42 -615.09
F8 N2 APARTMENT 23-DEC-10:55 1942.55 0.00 0.00 0.00 46.08 28.81 406.15 21.69 0.00 0.00 0.00 0.00 0.00 0.00 -1832.40 -612.87
F8 S1 APARTMENT 20-MAR-17:00 564.09 0.00 0.00 0.00 98.63 144.04 588.62 91.50 0.00 0.00 726.81 0.00 0.00 0.00 -2213.69 0.00
F8 S2 APARTMENT 20-MAR-17:00 556.73 0.00 0.00 0.00 98.63 144.04 588.62 91.27 0.00 0.00 734.40 0.00 0.00 0.00 -2213.69 0.00
F9 SW APARTMENT 05-FEB-07:15 1343.83 0.00 0.00 0.00 161.22 93.62 382.60 0.00 0.00 0.00 431.72 0.00 -1676.74 0.00 -736.26 0.00
F9 NW APARTMENT 10-MAR-12:25 1947.68 0.00 0.00 0.00 45.31 28.81 406.15 186.94 0.00 0.00 0.00 0.00 0.00 0.00 -2001.56 -613.32
F9 SE APARTMENT 16-FEB-06:15 1450.32 0.00 0.00 0.00 174.53 100.83 317.85 0.00 0.00 0.00 65.90 0.00 -691.79 0.00 -1417.64 0.00
F9 NE APARTMENT 10-MAR-12:25 2147.57 0.00 0.00 0.00 45.53 28.81 406.15 173.79 0.00 0.00 0.00 0.00 0.00 0.00 -1992.41 -809.44
F9 N1 APARTMENT 23-DEC-10:55 1927.72 0.00 0.00 0.00 46.31 28.81 406.15 21.24 0.00 0.00 0.00 0.00 0.00 0.00 -1897.50 -532.72
F9 N2 APARTMENT 23-DEC-10:55 1926.62 0.00 0.00 0.00 46.31 28.81 406.15 21.25 0.00 0.00 0.00 0.00 0.00 0.00 -1897.48 -531.66
F9 S1 APARTMENT 16-FEB-06:15 780.46 0.00 0.00 0.00 170.84 100.83 317.85 0.00 0.00 0.00 441.60 0.00 -437.08 0.00 -1374.50 0.00
F9 S2 APARTMENT 16-FEB-06:15 782.82 0.00 0.00 0.00 170.95 100.83 317.85 0.00 0.00 0.00 438.11 0.00 -436.39 0.00 -1374.17 0.00
T SW APARTMENT 05-FEB-07:10 2108.79 0.00 0.00 0.00 161.22 93.62 382.60 0.00 0.00 0.00 0.00 0.00 -1644.16 0.00 -764.38 -337.70
T NW APARTMENT 05-FEB-07:10 2237.00 0.00 0.00 0.00 161.22 93.62 382.60 0.00 0.00 0.00 0.00 0.00 -1667.90 0.00 -764.38 -442.17
T SE APARTMENT 05-FEB-07:10 2120.63 0.00 0.00 0.00 161.22 93.62 382.60 0.00 0.00 0.00 0.00 0.00 -1643.55 0.00 -764.38 -350.14
T NE APARTMENT 05-FEB-07:10 2244.23 0.00 0.00 0.00 161.22 93.62 382.60 0.00 0.00 0.00 0.00 0.00 -1667.52 0.00 -764.38 -449.77
T N1 APARTMENT 07-DEC-09:55 2079.20 0.00 0.00 0.00 45.23 28.81 394.37 0.00 0.00 0.00 0.00 0.00 -29.56 0.00 -2041.99 -476.05
T N2 APARTMENT 07-DEC-09:55 2080.97 0.00 0.00 0.00 45.21 28.81 394.37 0.00 0.00 0.00 0.00 0.00 -30.09 0.00 -2042.19 -477.08
T S1 APARTMENT 28-DEC-21:15 1148.01 0.00 0.00 0.00 189.67 158.44 500.33 0.00 0.00 0.00 437.14 0.00 -284.08 0.00 -2149.51 0.00
T S2 APARTMENT 28-DEC-21:15 1151.25 0.00 0.00 0.00 189.67 158.44 500.33 0.00 0.00 0.00 433.80 0.00 -283.98 0.00 -2149.51 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 05-FEB-07:15 63733.15 0.00 0.00 0.00 12736.44 14239.10 30866.16 0.00 0.00 0.00 38429.34 0.00 -107442.61 0.00 -52561.56 0.00



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Sec1.1A-General Information

Data
Weather File Tampa-MacDill AFB FL USA TMY3 WMO#=747880
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 7836.48
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.50
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
F2 SW APARTMENT 88.25 88.25 0.00 168.00
F2 NW APARTMENT 88.25 88.25 0.00 168.00
F2 SE APARTMENT 88.25 88.25 0.00 168.00
F2 NE APARTMENT 88.25 88.25 0.00 168.00
F2 N1 APARTMENT 88.25 88.25 0.00 168.00
F2 N2 APARTMENT 88.25 88.25 0.00 168.00
F2 S1 APARTMENT 88.25 88.25 0.00 168.00
F2 S2 APARTMENT 88.25 88.25 0.00 168.00
F3 SW APARTMENT 88.25 88.25 0.00 168.00
F3 NW APARTMENT 88.25 88.25 0.00 168.00
F3 SE APARTMENT 88.25 88.25 0.00 168.00
F3 NE APARTMENT 88.25 88.25 0.00 168.00
F3 N1 APARTMENT 88.25 88.25 0.00 168.00
F3 N2 APARTMENT 88.25 88.25 0.00 168.00
F3 S1 APARTMENT 88.25 88.25 0.00 168.00
F3 S2 APARTMENT 88.25 88.25 0.00 168.00
F4 SW APARTMENT 88.25 88.25 0.00 168.00
F4 NW APARTMENT 88.25 88.25 0.00 168.00
F4 SE APARTMENT 88.25 88.25 0.00 168.00
F4 NE APARTMENT 88.25 88.25 0.00 168.00
F4 N1 APARTMENT 88.25 88.25 0.00 168.00
F4 N2 APARTMENT 88.25 88.25 0.00 168.00
F4 S1 APARTMENT 88.25 88.25 0.00 168.00
F4 S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
F6 SW APARTMENT 88.25 88.25 0.00 168.00
F6 NW APARTMENT 88.25 88.25 0.00 168.00
F6 SE APARTMENT 88.25 88.25 0.00 168.00
F6 NE APARTMENT 88.25 88.25 0.00 168.00
F6 N1 APARTMENT 88.25 88.25 0.00 168.00
F6 N2 APARTMENT 88.25 88.25 0.00 168.00
F6 S1 APARTMENT 88.25 88.25 0.00 168.00
F6 S2 APARTMENT 88.25 88.25 0.00 168.00
F7 SW APARTMENT 88.25 88.25 0.00 168.00
F7 NW APARTMENT 88.25 88.25 0.00 168.00
F7 SE APARTMENT 88.25 88.25 0.00 168.00
F7 NE APARTMENT 88.25 88.25 0.00 168.00
F7 N1 APARTMENT 88.25 88.25 0.00 168.00
F7 N2 APARTMENT 88.25 88.25 0.00 168.00
F7 S1 APARTMENT 88.25 88.25 0.00 168.00
F7 S2 APARTMENT 88.25 88.25 0.00 168.00
F8 SW APARTMENT 88.25 88.25 0.00 168.00
F8 NW APARTMENT 88.25 88.25 0.00 168.00
F8 SE APARTMENT 88.25 88.25 0.00 168.00
F8 NE APARTMENT 88.25 88.25 0.00 168.00
F8 N1 APARTMENT 88.25 88.25 0.00 168.00
F8 N2 APARTMENT 88.25 88.25 0.00 168.00
F8 S1 APARTMENT 88.25 88.25 0.00 168.00
F8 S2 APARTMENT 88.25 88.25 0.00 168.00
F9 SW APARTMENT 88.25 88.25 0.00 168.00
F9 NW APARTMENT 88.25 88.25 0.00 168.00
F9 SE APARTMENT 88.25 88.25 0.00 168.00
F9 NE APARTMENT 88.25 88.25 0.00 168.00
F9 N1 APARTMENT 88.25 88.25 0.00 168.00
F9 N2 APARTMENT 88.25 88.25 0.00 168.00
F9 S1 APARTMENT 88.25 88.25 0.00 168.00
F9 S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
G CORRIDOR 77.66 0.00 77.66 0.00
F2 CORRIDOR 77.66 0.00 77.66 0.00
F3 CORRIDOR 77.66 0.00 77.66 0.00
F4 CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
F6 CORRIDOR 77.66 0.00 77.66 0.00
F7 CORRIDOR 77.66 0.00 77.66 0.00
F8 CORRIDOR 77.66 0.00 77.66 0.00
F9 CORRIDOR 77.66 0.00 77.66 0.00
T CORRIDOR 77.66 0.00 77.66 0.00
Totals 7836.48 7059.89 776.58  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 18.75
Number of hours cooling loads not met 565.00
Number of hours not met 583.75


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 416.41 25049.15 0.00 0.00 0.00 0.00
Exterior Lighting 168.41 10720.10 0.00 0.00 0.00 0.00
Space Heating 10.11 0.00 13.16 100597.46 0.00 0.00
Space Cooling 1107.49 84175.21 0.00 0.00 0.00 0.00
Pumps 56.82 1860.65 0.00 0.00 0.00 0.00
Heat Rejection 55.24 3451.82 0.00 0.00 0.00 0.00
Fans-Interior 604.09 19155.52 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 0.00 0.00 894.05 79131.82 0.00 0.00
Receptacle Equipment 1131.09 49704.83 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 3570.48   907.21   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 1131.09 3570.48
Natural Gas 0.00 907.21
Additional 0.00 0.00
Total 1131.09 4477.69


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 53.14
Space Heating 1.29
Space Cooling 141.32
Fans-Interior 77.09
Service Water Heating 0.00
Receptacle Equipment 144.34
Miscellaneous 38.45
Subtotal 455.62


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 1.68
Service Water Heating 114.09
Miscellaneous -0.00
Subtotal 115.77


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 9.30
Space Heating 0.52
Space Cooling 24.73
Fans-Interior 13.49
Service Water Heating 19.97
Receptacle Equipment 25.26
Miscellaneous 6.73



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.251203
G NW APARTMENT DIRECT AIR 0.233413
OFFICE DIRECT AIR 0.320355
G NE APARTMENT DIRECT AIR 0.193551
G N1 APARTMENT DIRECT AIR 0.107651
G N2 APARTMENT DIRECT AIR 0.106554
G S1 APARTMENT DIRECT AIR 0.147219
G S2 APARTMENT DIRECT AIR 0.151947
F2 SW APARTMENT DIRECT AIR 0.292889
F2 NW APARTMENT DIRECT AIR 0.272466
F2 SE APARTMENT DIRECT AIR 0.274566
F2 NE APARTMENT DIRECT AIR 0.228129
F2 N1 APARTMENT DIRECT AIR 0.133724
F2 N2 APARTMENT DIRECT AIR 0.132858
F2 S1 APARTMENT DIRECT AIR 0.175995
F2 S2 APARTMENT DIRECT AIR 0.177683
F3 SW APARTMENT DIRECT AIR 0.291996
F3 NW APARTMENT DIRECT AIR 0.272472
F3 SE APARTMENT DIRECT AIR 0.259502
F3 NE APARTMENT DIRECT AIR 0.229421
F3 N1 APARTMENT DIRECT AIR 0.135682
F3 N2 APARTMENT DIRECT AIR 0.134826
F3 S1 APARTMENT DIRECT AIR 0.177080
F3 S2 APARTMENT DIRECT AIR 0.177852
F4 SW APARTMENT DIRECT AIR 0.291733
F4 NW APARTMENT DIRECT AIR 0.272579
F4 SE APARTMENT DIRECT AIR 0.257952
F4 NE APARTMENT DIRECT AIR 0.229771
F4 N1 APARTMENT DIRECT AIR 0.136968
F4 N2 APARTMENT DIRECT AIR 0.136120
F4 S1 APARTMENT DIRECT AIR 0.177539
F4 S2 APARTMENT DIRECT AIR 0.178174
M SW APARTMENT DIRECT AIR 0.293779
M NW APARTMENT DIRECT AIR 0.274980
M SE APARTMENT DIRECT AIR 0.260041
M NE APARTMENT DIRECT AIR 0.232349
M N1 APARTMENT DIRECT AIR 0.140215
M N2 APARTMENT DIRECT AIR 0.139374
M S1 APARTMENT DIRECT AIR 0.180068
M S2 APARTMENT DIRECT AIR 0.180682
F6 SW APARTMENT DIRECT AIR 0.289799
F6 NW APARTMENT DIRECT AIR 0.271177
F6 SE APARTMENT DIRECT AIR 0.256312
F6 NE APARTMENT DIRECT AIR 0.228812
F6 N1 APARTMENT DIRECT AIR 0.137427
F6 N2 APARTMENT DIRECT AIR 0.136598
F6 S1 APARTMENT DIRECT AIR 0.176704
F6 S2 APARTMENT DIRECT AIR 0.177314
F7 SW APARTMENT DIRECT AIR 0.288126
F7 NW APARTMENT DIRECT AIR 0.269745
F7 SE APARTMENT DIRECT AIR 0.254876
F7 NE APARTMENT DIRECT AIR 0.227598
F7 N1 APARTMENT DIRECT AIR 0.136796
F7 N2 APARTMENT DIRECT AIR 0.135975
F7 S1 APARTMENT DIRECT AIR 0.175531
F7 S2 APARTMENT DIRECT AIR 0.176139
F8 SW APARTMENT DIRECT AIR 0.287886
F8 NW APARTMENT DIRECT AIR 0.269707
F8 SE APARTMENT DIRECT AIR 0.254808
F8 NE APARTMENT DIRECT AIR 0.227736
F8 N1 APARTMENT DIRECT AIR 0.137465
F8 N2 APARTMENT DIRECT AIR 0.136654
F8 S1 APARTMENT DIRECT AIR 0.175673
F8 S2 APARTMENT DIRECT AIR 0.176281
F9 SW APARTMENT DIRECT AIR 0.295197
F9 NW APARTMENT DIRECT AIR 0.277225
F9 SE APARTMENT DIRECT AIR 0.258645
F9 NE APARTMENT DIRECT AIR 0.231264
F9 N1 APARTMENT DIRECT AIR 0.144860
F9 N2 APARTMENT DIRECT AIR 0.144053
F9 S1 APARTMENT DIRECT AIR 0.180689
F9 S2 APARTMENT DIRECT AIR 0.181360
T SW APARTMENT DIRECT AIR 0.353305
T NW APARTMENT DIRECT AIR 0.331335
T SE APARTMENT DIRECT AIR 0.307598
T NE APARTMENT DIRECT AIR 0.271931
T N1 APARTMENT DIRECT AIR 0.188188
T N2 APARTMENT DIRECT AIR 0.188262
T S1 APARTMENT DIRECT AIR 0.240158
T S2 APARTMENT DIRECT AIR 0.240929


Branch

Maximum Flow Rate [m3/s]
AIRLOOP G SW MAIN BRANCH 0.251203
AIRLOOP G NW MAIN BRANCH 0.233413
AIRLOOP OFFICE MAIN BRANCH 0.320355
AIRLOOP G NE MAIN BRANCH 0.193551
AIRLOOP G N1 MAIN BRANCH 0.107651
AIRLOOP G N2 MAIN BRANCH 0.106554
AIRLOOP G S1 MAIN BRANCH 0.147219
AIRLOOP G S2 MAIN BRANCH 0.151947
AIRLOOP F2 SW MAIN BRANCH 0.292889
AIRLOOP F2 NW MAIN BRANCH 0.272466
AIRLOOP F2 SE MAIN BRANCH 0.274566
AIRLOOP F2 NE MAIN BRANCH 0.228129
AIRLOOP F2 N1 MAIN BRANCH 0.133724
AIRLOOP F2 N2 MAIN BRANCH 0.132858
AIRLOOP F2 S1 MAIN BRANCH 0.175995
AIRLOOP F2 S2 MAIN BRANCH 0.177683
AIRLOOP F3 SW MAIN BRANCH 0.291996
AIRLOOP F3 NW MAIN BRANCH 0.272472
AIRLOOP F3 SE MAIN BRANCH 0.259502
AIRLOOP F3 NE MAIN BRANCH 0.229421
AIRLOOP F3 N1 MAIN BRANCH 0.135682
AIRLOOP F3 N2 MAIN BRANCH 0.134826
AIRLOOP F3 S1 MAIN BRANCH 0.177080
AIRLOOP F3 S2 MAIN BRANCH 0.177852
AIRLOOP F4 SW MAIN BRANCH 0.291733
AIRLOOP F4 NW MAIN BRANCH 0.272579
AIRLOOP F4 SE MAIN BRANCH 0.257952
AIRLOOP F4 NE MAIN BRANCH 0.229771
AIRLOOP F4 N1 MAIN BRANCH 0.136968
AIRLOOP F4 N2 MAIN BRANCH 0.136120
AIRLOOP F4 S1 MAIN BRANCH 0.177539
AIRLOOP F4 S2 MAIN BRANCH 0.178174
AIRLOOP M SW MAIN BRANCH 0.293779
AIRLOOP M NW MAIN BRANCH 0.274980
AIRLOOP M SE MAIN BRANCH 0.260041
AIRLOOP M NE MAIN BRANCH 0.232349
AIRLOOP M N1 MAIN BRANCH 0.140215
AIRLOOP M N2 MAIN BRANCH 0.139374
AIRLOOP M S1 MAIN BRANCH 0.180068
AIRLOOP M S2 MAIN BRANCH 0.180682
AIRLOOP F6 SW MAIN BRANCH 0.289799
AIRLOOP F6 NW MAIN BRANCH 0.271177
AIRLOOP F6 SE MAIN BRANCH 0.256312
AIRLOOP F6 NE MAIN BRANCH 0.228812
AIRLOOP F6 N1 MAIN BRANCH 0.137427
AIRLOOP F6 N2 MAIN BRANCH 0.136598
AIRLOOP F6 S1 MAIN BRANCH 0.176704
AIRLOOP F6 S2 MAIN BRANCH 0.177314
AIRLOOP F7 SW MAIN BRANCH 0.288126
AIRLOOP F7 NW MAIN BRANCH 0.269745
AIRLOOP F7 SE MAIN BRANCH 0.254876
AIRLOOP F7 NE MAIN BRANCH 0.227598
AIRLOOP F7 N1 MAIN BRANCH 0.136796
AIRLOOP F7 N2 MAIN BRANCH 0.135975
AIRLOOP F7 S1 MAIN BRANCH 0.175531
AIRLOOP F7 S2 MAIN BRANCH 0.176139
AIRLOOP F8 SW MAIN BRANCH 0.287886
AIRLOOP F8 NW MAIN BRANCH 0.269707
AIRLOOP F8 SE MAIN BRANCH 0.254808
AIRLOOP F8 NE MAIN BRANCH 0.227736
AIRLOOP F8 N1 MAIN BRANCH 0.137465
AIRLOOP F8 N2 MAIN BRANCH 0.136654
AIRLOOP F8 S1 MAIN BRANCH 0.175673
AIRLOOP F8 S2 MAIN BRANCH 0.176281
AIRLOOP F9 SW MAIN BRANCH 0.295197
AIRLOOP F9 NW MAIN BRANCH 0.277225
AIRLOOP F9 SE MAIN BRANCH 0.258645
AIRLOOP F9 NE MAIN BRANCH 0.231264
AIRLOOP F9 N1 MAIN BRANCH 0.144860
AIRLOOP F9 N2 MAIN BRANCH 0.144053
AIRLOOP F9 S1 MAIN BRANCH 0.180689
AIRLOOP F9 S2 MAIN BRANCH 0.181360
AIRLOOP T SW MAIN BRANCH 0.353305
AIRLOOP T NW MAIN BRANCH 0.331335
AIRLOOP T SE MAIN BRANCH 0.307598
AIRLOOP T NE MAIN BRANCH 0.271931
AIRLOOP T N1 MAIN BRANCH 0.188188
AIRLOOP T N2 MAIN BRANCH 0.188262
AIRLOOP T S1 MAIN BRANCH 0.240158
AIRLOOP T S2 MAIN BRANCH 0.240929


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
AIRLOOP G SW 0.251203
AIRLOOP G NW 0.233413
AIRLOOP OFFICE 0.320355
AIRLOOP G NE 0.193551
AIRLOOP G N1 0.107651
AIRLOOP G N2 0.106554
AIRLOOP G S1 0.147219
AIRLOOP G S2 0.151947
AIRLOOP F2 SW 0.292889
AIRLOOP F2 NW 0.272466
AIRLOOP F2 SE 0.274566
AIRLOOP F2 NE 0.228129
AIRLOOP F2 N1 0.133724
AIRLOOP F2 N2 0.132858
AIRLOOP F2 S1 0.175995
AIRLOOP F2 S2 0.177683
AIRLOOP F3 SW 0.291996
AIRLOOP F3 NW 0.272472
AIRLOOP F3 SE 0.259502
AIRLOOP F3 NE 0.229421
AIRLOOP F3 N1 0.135682
AIRLOOP F3 N2 0.134826
AIRLOOP F3 S1 0.177080
AIRLOOP F3 S2 0.177852
AIRLOOP F4 SW 0.291733
AIRLOOP F4 NW 0.272579
AIRLOOP F4 SE 0.257952
AIRLOOP F4 NE 0.229771
AIRLOOP F4 N1 0.136968
AIRLOOP F4 N2 0.136120
AIRLOOP F4 S1 0.177539
AIRLOOP F4 S2 0.178174
AIRLOOP M SW 0.293779
AIRLOOP M NW 0.274980
AIRLOOP M SE 0.260041
AIRLOOP M NE 0.232349
AIRLOOP M N1 0.140215
AIRLOOP M N2 0.139374
AIRLOOP M S1 0.180068
AIRLOOP M S2 0.180682
AIRLOOP F6 SW 0.289799
AIRLOOP F6 NW 0.271177
AIRLOOP F6 SE 0.256312
AIRLOOP F6 NE 0.228812
AIRLOOP F6 N1 0.137427
AIRLOOP F6 N2 0.136598
AIRLOOP F6 S1 0.176704
AIRLOOP F6 S2 0.177314
AIRLOOP F7 SW 0.288126
AIRLOOP F7 NW 0.269745
AIRLOOP F7 SE 0.254876
AIRLOOP F7 NE 0.227598
AIRLOOP F7 N1 0.136796
AIRLOOP F7 N2 0.135975
AIRLOOP F7 S1 0.175531
AIRLOOP F7 S2 0.176139
AIRLOOP F8 SW 0.287886
AIRLOOP F8 NW 0.269707
AIRLOOP F8 SE 0.254808
AIRLOOP F8 NE 0.227736
AIRLOOP F8 N1 0.137465
AIRLOOP F8 N2 0.136654
AIRLOOP F8 S1 0.175673
AIRLOOP F8 S2 0.176281
AIRLOOP F9 SW 0.295197
AIRLOOP F9 NW 0.277225
AIRLOOP F9 SE 0.258645
AIRLOOP F9 NE 0.231264
AIRLOOP F9 N1 0.144860
AIRLOOP F9 N2 0.144053
AIRLOOP F9 S1 0.180689
AIRLOOP F9 S2 0.181360
AIRLOOP T SW 0.353305
AIRLOOP T NW 0.331335
AIRLOOP T SE 0.307598
AIRLOOP T NE 0.271931
AIRLOOP T N1 0.188188
AIRLOOP T N2 0.188262
AIRLOOP T S1 0.240158
AIRLOOP T S2 0.240929


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
AIRLOOP G SW OA CONTROLLER 0.251203 0.025952
AIRLOOP G NW OA CONTROLLER 0.233413 0.025952
AIRLOOP OFFICE OA CONTROLLER 0.320355 0.038103
AIRLOOP G NE OA CONTROLLER 0.193551 0.025952
AIRLOOP G N1 OA CONTROLLER 0.107651 0.025952
AIRLOOP G N2 OA CONTROLLER 0.106554 0.025952
AIRLOOP G S1 OA CONTROLLER 0.147219 0.025952
AIRLOOP G S2 OA CONTROLLER 0.151947 0.025952
AIRLOOP F2 SW OA CONTROLLER 0.292889 0.025952
AIRLOOP F2 NW OA CONTROLLER 0.272466 0.025952
AIRLOOP F2 SE OA CONTROLLER 0.274566 0.025952
AIRLOOP F2 NE OA CONTROLLER 0.228129 0.025952
AIRLOOP F2 N1 OA CONTROLLER 0.133724 0.025952
AIRLOOP F2 N2 OA CONTROLLER 0.132858 0.025952
AIRLOOP F2 S1 OA CONTROLLER 0.175995 0.025952
AIRLOOP F2 S2 OA CONTROLLER 0.177683 0.025952
AIRLOOP F3 SW OA CONTROLLER 0.291996 0.025952
AIRLOOP F3 NW OA CONTROLLER 0.272472 0.025952
AIRLOOP F3 SE OA CONTROLLER 0.259502 0.025952
AIRLOOP F3 NE OA CONTROLLER 0.229421 0.025952
AIRLOOP F3 N1 OA CONTROLLER 0.135682 0.025952
AIRLOOP F3 N2 OA CONTROLLER 0.134826 0.025952
AIRLOOP F3 S1 OA CONTROLLER 0.177080 0.025952
AIRLOOP F3 S2 OA CONTROLLER 0.177852 0.025952
AIRLOOP F4 SW OA CONTROLLER 0.291733 0.025952
AIRLOOP F4 NW OA CONTROLLER 0.272579 0.025952
AIRLOOP F4 SE OA CONTROLLER 0.257952 0.025952
AIRLOOP F4 NE OA CONTROLLER 0.229771 0.025952
AIRLOOP F4 N1 OA CONTROLLER 0.136968 0.025952
AIRLOOP F4 N2 OA CONTROLLER 0.136120 0.025952
AIRLOOP F4 S1 OA CONTROLLER 0.177539 0.025952
AIRLOOP F4 S2 OA CONTROLLER 0.178174 0.025952
AIRLOOP M SW OA CONTROLLER 0.293779 0.025952
AIRLOOP M NW OA CONTROLLER 0.274980 0.025952
AIRLOOP M SE OA CONTROLLER 0.260041 0.025952
AIRLOOP M NE OA CONTROLLER 0.232349 0.025952
AIRLOOP M N1 OA CONTROLLER 0.140215 0.025952
AIRLOOP M N2 OA CONTROLLER 0.139374 0.025952
AIRLOOP M S1 OA CONTROLLER 0.180068 0.025952
AIRLOOP M S2 OA CONTROLLER 0.180682 0.025952
AIRLOOP F6 SW OA CONTROLLER 0.289799 0.025952
AIRLOOP F6 NW OA CONTROLLER 0.271177 0.025952
AIRLOOP F6 SE OA CONTROLLER 0.256312 0.025952
AIRLOOP F6 NE OA CONTROLLER 0.228812 0.025952
AIRLOOP F6 N1 OA CONTROLLER 0.137427 0.025952
AIRLOOP F6 N2 OA CONTROLLER 0.136598 0.025952
AIRLOOP F6 S1 OA CONTROLLER 0.176704 0.025952
AIRLOOP F6 S2 OA CONTROLLER 0.177314 0.025952
AIRLOOP F7 SW OA CONTROLLER 0.288126 0.025952
AIRLOOP F7 NW OA CONTROLLER 0.269745 0.025952
AIRLOOP F7 SE OA CONTROLLER 0.254876 0.025952
AIRLOOP F7 NE OA CONTROLLER 0.227598 0.025952
AIRLOOP F7 N1 OA CONTROLLER 0.136796 0.025952
AIRLOOP F7 N2 OA CONTROLLER 0.135975 0.025952
AIRLOOP F7 S1 OA CONTROLLER 0.175531 0.025952
AIRLOOP F7 S2 OA CONTROLLER 0.176139 0.025952
AIRLOOP F8 SW OA CONTROLLER 0.287886 0.025952
AIRLOOP F8 NW OA CONTROLLER 0.269707 0.025952
AIRLOOP F8 SE OA CONTROLLER 0.254808 0.025952
AIRLOOP F8 NE OA CONTROLLER 0.227736 0.025952
AIRLOOP F8 N1 OA CONTROLLER 0.137465 0.025952
AIRLOOP F8 N2 OA CONTROLLER 0.136654 0.025952
AIRLOOP F8 S1 OA CONTROLLER 0.175673 0.025952
AIRLOOP F8 S2 OA CONTROLLER 0.176281 0.025952
AIRLOOP F9 SW OA CONTROLLER 0.295197 0.025952
AIRLOOP F9 NW OA CONTROLLER 0.277225 0.025952
AIRLOOP F9 SE OA CONTROLLER 0.258645 0.025952
AIRLOOP F9 NE OA CONTROLLER 0.231264 0.025952
AIRLOOP F9 N1 OA CONTROLLER 0.144860 0.025952
AIRLOOP F9 N2 OA CONTROLLER 0.144053 0.025952
AIRLOOP F9 S1 OA CONTROLLER 0.180689 0.025952
AIRLOOP F9 S2 OA CONTROLLER 0.181360 0.025952
AIRLOOP T SW OA CONTROLLER 0.353305 0.025952
AIRLOOP T NW OA CONTROLLER 0.331335 0.025952
AIRLOOP T SE OA CONTROLLER 0.307598 0.025952
AIRLOOP T NE OA CONTROLLER 0.271931 0.025952
AIRLOOP T N1 OA CONTROLLER 0.188188 0.025952
AIRLOOP T N2 OA CONTROLLER 0.188262 0.025952
AIRLOOP T S1 OA CONTROLLER 0.240158 0.025952
AIRLOOP T S2 OA CONTROLLER 0.240929 0.025952


COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity [W] Rated Sensible Cooling Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP COOLING MODE AIRLOOP G SW 0.251203 4563.88 3111.56 0.000100
HEAT PUMP COOLING MODE AIRLOOP G NW 0.233413 4297.11 2908.93 0.000094
HEAT PUMP COOLING MODE AIRLOOP OFFICE 0.320355 5878.40 3986.43 0.000128
HEAT PUMP COOLING MODE AIRLOOP G NE 0.193551 3688.42 2452.89 0.000081
HEAT PUMP COOLING MODE AIRLOOP G N1 0.107651 2416.46 1504.00 0.000053
HEAT PUMP COOLING MODE AIRLOOP G N2 0.106554 2399.94 1491.91 0.000052
HEAT PUMP COOLING MODE AIRLOOP G S1 0.147219 3038.39 1958.97 0.000066
HEAT PUMP COOLING MODE AIRLOOP G S2 0.151947 3106.59 2010.88 0.000068
HEAT PUMP COOLING MODE AIRLOOP F2 SW 0.292889 5208.47 3584.96 0.000114
HEAT PUMP COOLING MODE AIRLOOP F2 NW 0.272466 4908.76 3355.31 0.000107
HEAT PUMP COOLING MODE AIRLOOP F2 SE 0.274566 4924.55 3372.44 0.000108
HEAT PUMP COOLING MODE AIRLOOP F2 NE 0.228129 4234.91 2848.98 0.000093
HEAT PUMP COOLING MODE AIRLOOP F2 N1 0.133724 2832.21 1802.02 0.000062
HEAT PUMP COOLING MODE AIRLOOP F2 N2 0.132858 2819.34 1792.46 0.000062
HEAT PUMP COOLING MODE AIRLOOP F2 S1 0.175995 3485.83 2286.54 0.000076
HEAT PUMP COOLING MODE AIRLOOP F2 S2 0.177683 3510.09 2305.09 0.000077
HEAT PUMP COOLING MODE AIRLOOP F3 SW 0.291996 5229.11 3585.55 0.000114
HEAT PUMP COOLING MODE AIRLOOP F3 NW 0.272472 4941.72 3365.77 0.000108
HEAT PUMP COOLING MODE AIRLOOP F3 SE 0.259502 4742.64 3217.40 0.000104
HEAT PUMP COOLING MODE AIRLOOP F3 NE 0.229421 4285.20 2873.52 0.000094
HEAT PUMP COOLING MODE AIRLOOP F3 N1 0.135682 2877.69 1829.59 0.000063
HEAT PUMP COOLING MODE AIRLOOP F3 N2 0.134826 2864.95 1820.13 0.000063
HEAT PUMP COOLING MODE AIRLOOP F3 S1 0.177080 3519.71 2304.62 0.000077
HEAT PUMP COOLING MODE AIRLOOP F3 S2 0.177852 3530.77 2313.08 0.000077
HEAT PUMP COOLING MODE AIRLOOP F4 SW 0.291733 5250.32 3590.49 0.000115
HEAT PUMP COOLING MODE AIRLOOP F4 NW 0.272579 4967.87 3374.76 0.000109
HEAT PUMP COOLING MODE AIRLOOP F4 SE 0.257952 4744.89 3208.19 0.000104
HEAT PUMP COOLING MODE AIRLOOP F4 NE 0.229771 4314.05 2885.18 0.000094
HEAT PUMP COOLING MODE AIRLOOP F4 N1 0.136968 2909.18 1848.29 0.000064
HEAT PUMP COOLING MODE AIRLOOP F4 N2 0.136120 2896.54 1838.92 0.000063
HEAT PUMP COOLING MODE AIRLOOP F4 S1 0.177539 3540.03 2314.30 0.000077
HEAT PUMP COOLING MODE AIRLOOP F4 S2 0.178174 3549.13 2321.25 0.000078
HEAT PUMP COOLING MODE AIRLOOP M SW 0.293779 5299.91 3619.41 0.000116
HEAT PUMP COOLING MODE AIRLOOP M NW 0.274980 5022.30 3407.56 0.000110
HEAT PUMP COOLING MODE AIRLOOP M SE 0.260041 4794.68 3237.54 0.000105
HEAT PUMP COOLING MODE AIRLOOP M NE 0.232349 4370.47 2919.86 0.000095
HEAT PUMP COOLING MODE AIRLOOP M N1 0.140215 2967.41 1887.74 0.000065
HEAT PUMP COOLING MODE AIRLOOP M N2 0.139374 2954.87 1878.45 0.000065
HEAT PUMP COOLING MODE AIRLOOP M S1 0.180068 3587.83 2345.92 0.000078
HEAT PUMP COOLING MODE AIRLOOP M S2 0.180682 3596.63 2352.65 0.000079
HEAT PUMP COOLING MODE AIRLOOP F6 SW 0.289799 5260.45 3581.16 0.000115
HEAT PUMP COOLING MODE AIRLOOP F6 NW 0.271177 4984.97 3371.24 0.000109
HEAT PUMP COOLING MODE AIRLOOP F6 SE 0.256312 4758.17 3202.05 0.000104
HEAT PUMP COOLING MODE AIRLOOP F6 NE 0.228812 4336.22 2886.55 0.000095
HEAT PUMP COOLING MODE AIRLOOP F6 N1 0.137427 2934.90 1860.27 0.000064
HEAT PUMP COOLING MODE AIRLOOP F6 N2 0.136598 2922.48 1851.10 0.000064
HEAT PUMP COOLING MODE AIRLOOP F6 S1 0.176704 3548.68 2312.17 0.000078
HEAT PUMP COOLING MODE AIRLOOP F6 S2 0.177314 3557.43 2318.85 0.000078
HEAT PUMP COOLING MODE AIRLOOP F7 SW 0.288126 5251.79 3567.63 0.000115
HEAT PUMP COOLING MODE AIRLOOP F7 NW 0.269745 4979.44 3360.34 0.000109
HEAT PUMP COOLING MODE AIRLOOP F7 SE 0.254876 4752.39 3191.09 0.000104
HEAT PUMP COOLING MODE AIRLOOP F7 NE 0.227598 4333.24 2878.05 0.000095
HEAT PUMP COOLING MODE AIRLOOP F7 N1 0.136796 2933.17 1856.14 0.000064
HEAT PUMP COOLING MODE AIRLOOP F7 N2 0.135975 2920.85 1847.06 0.000064
HEAT PUMP COOLING MODE AIRLOOP F7 S1 0.175531 3540.03 2302.12 0.000077
HEAT PUMP COOLING MODE AIRLOOP F7 S2 0.176139 3548.77 2308.79 0.000078
HEAT PUMP COOLING MODE AIRLOOP F8 SW 0.287886 5262.02 3569.34 0.000115
HEAT PUMP COOLING MODE AIRLOOP F8 NW 0.269707 4992.36 3364.27 0.000109
HEAT PUMP COOLING MODE AIRLOOP F8 SE 0.254808 4764.71 3194.69 0.000104
HEAT PUMP COOLING MODE AIRLOOP F8 NE 0.227736 4353.82 2887.02 0.000095
HEAT PUMP COOLING MODE AIRLOOP F8 N1 0.137465 2949.97 1866.04 0.000064
HEAT PUMP COOLING MODE AIRLOOP F8 N2 0.136654 2937.77 1857.06 0.000064
HEAT PUMP COOLING MODE AIRLOOP F8 S1 0.175673 3549.61 2306.27 0.000078
HEAT PUMP COOLING MODE AIRLOOP F8 S2 0.176281 3558.35 2312.93 0.000078
HEAT PUMP COOLING MODE AIRLOOP F9 SW 0.295197 5379.36 3653.76 0.000118
HEAT PUMP COOLING MODE AIRLOOP F9 NW 0.277225 5112.77 3450.96 0.000112
HEAT PUMP COOLING MODE AIRLOOP F9 SE 0.258645 4832.22 3240.89 0.000106
HEAT PUMP COOLING MODE AIRLOOP F9 NE 0.231264 4416.77 2929.78 0.000096
HEAT PUMP COOLING MODE AIRLOOP F9 N1 0.144860 3066.27 1949.83 0.000067
HEAT PUMP COOLING MODE AIRLOOP F9 N2 0.144053 3054.17 1940.90 0.000067
HEAT PUMP COOLING MODE AIRLOOP F9 S1 0.180689 3629.65 2363.94 0.000079
HEAT PUMP COOLING MODE AIRLOOP F9 S2 0.181360 3639.31 2371.30 0.000079
HEAT PUMP COOLING MODE AIRLOOP T SW 0.353305 6227.30 4299.89 0.000136
HEAT PUMP COOLING MODE AIRLOOP T NW 0.331335 5903.58 4052.75 0.000129
HEAT PUMP COOLING MODE AIRLOOP T SE 0.307598 5551.15 3785.31 0.000121
HEAT PUMP COOLING MODE AIRLOOP T NE 0.271931 5022.58 3384.49 0.000110
HEAT PUMP COOLING MODE AIRLOOP T N1 0.188188 3746.82 2449.66 0.000082
HEAT PUMP COOLING MODE AIRLOOP T N2 0.188262 3747.64 2450.39 0.000082
HEAT PUMP COOLING MODE AIRLOOP T S1 0.240158 4494.04 3020.53 0.000098
HEAT PUMP COOLING MODE AIRLOOP T S2 0.240929 4504.97 3028.97 0.000098


AirLoopHVAC:UnitaryHeatPump:WaterToAir

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Supplemental Heating Coil Nominal Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
AIRLOOP G SW DXAC HEAT PUMP 0.251203 0.251203 0.251203 0.251203 4563.88 4563.88 1705.49 1.00
AIRLOOP G NW DXAC HEAT PUMP 0.233413 0.233413 0.233413 0.233413 4297.11 4297.11 1700.37 1.00
AIRLOOP OFFICE DXAC HEAT PUMP 0.320355 0.320355 0.320355 0.320355 5878.40 5878.40 2346.75 1.00
AIRLOOP G NE DXAC HEAT PUMP 0.193551 0.193551 0.193551 0.193551 3688.42 3688.42 1700.37 1.00
AIRLOOP G N1 DXAC HEAT PUMP 0.107651 0.107651 0.107651 0.107651 2416.46 2416.46 1197.34 1.00
AIRLOOP G N2 DXAC HEAT PUMP 0.106554 0.106554 0.106554 0.106554 2399.94 2399.94 1197.34 1.00
AIRLOOP G S1 DXAC HEAT PUMP 0.147219 0.147219 0.147219 0.147219 3038.39 3038.39 1200.38 1.00
AIRLOOP G S2 DXAC HEAT PUMP 0.151947 0.151947 0.151947 0.151947 3106.59 3106.59 1208.79 1.00
AIRLOOP F2 SW DXAC HEAT PUMP 0.292889 0.292889 0.292889 0.292889 5208.47 5208.47 1642.13 1.00
AIRLOOP F2 NW DXAC HEAT PUMP 0.272466 0.272466 0.272466 0.272466 4908.76 4908.76 1637.22 1.00
AIRLOOP F2 SE DXAC HEAT PUMP 0.274566 0.274566 0.274566 0.274566 4924.55 4924.55 1668.43 1.00
AIRLOOP F2 NE DXAC HEAT PUMP 0.228129 0.228129 0.228129 0.228129 4234.91 4234.91 1637.22 1.00
AIRLOOP F2 N1 DXAC HEAT PUMP 0.133724 0.133724 0.133724 0.133724 2832.21 2832.21 1110.74 1.00
AIRLOOP F2 N2 DXAC HEAT PUMP 0.132858 0.132858 0.132858 0.132858 2819.34 2819.34 1110.74 1.00
AIRLOOP F2 S1 DXAC HEAT PUMP 0.175995 0.175995 0.175995 0.175995 3485.83 3485.83 1110.74 1.00
AIRLOOP F2 S2 DXAC HEAT PUMP 0.177683 0.177683 0.177683 0.177683 3510.09 3510.09 1110.74 1.00
AIRLOOP F3 SW DXAC HEAT PUMP 0.291996 0.291996 0.291996 0.291996 5229.11 5229.11 1618.17 1.00
AIRLOOP F3 NW DXAC HEAT PUMP 0.272472 0.272472 0.272472 0.272472 4941.72 4941.72 1614.57 1.00
AIRLOOP F3 SE DXAC HEAT PUMP 0.259502 0.259502 0.259502 0.259502 4742.64 4742.64 1621.51 1.00
AIRLOOP F3 NE DXAC HEAT PUMP 0.229421 0.229421 0.229421 0.229421 4285.20 4285.20 1614.57 1.00
AIRLOOP F3 N1 DXAC HEAT PUMP 0.135682 0.135682 0.135682 0.135682 2877.69 2877.69 1110.74 1.00
AIRLOOP F3 N2 DXAC HEAT PUMP 0.134826 0.134826 0.134826 0.134826 2864.95 2864.95 1110.74 1.00
AIRLOOP F3 S1 DXAC HEAT PUMP 0.177080 0.177080 0.177080 0.177080 3519.71 3519.71 1110.74 1.00
AIRLOOP F3 S2 DXAC HEAT PUMP 0.177852 0.177852 0.177852 0.177852 3530.77 3530.77 1110.74 1.00
AIRLOOP F4 SW DXAC HEAT PUMP 0.291733 0.291733 0.291733 0.291733 5250.32 5250.32 1627.15 1.00
AIRLOOP F4 NW DXAC HEAT PUMP 0.272579 0.272579 0.272579 0.272579 4967.87 4967.87 1625.28 1.00
AIRLOOP F4 SE DXAC HEAT PUMP 0.257952 0.257952 0.257952 0.257952 4744.89 4744.89 1627.56 1.00
AIRLOOP F4 NE DXAC HEAT PUMP 0.229771 0.229771 0.229771 0.229771 4314.05 4314.05 1625.28 1.00
AIRLOOP F4 N1 DXAC HEAT PUMP 0.136968 0.136968 0.136968 0.136968 2909.18 2909.18 1110.74 1.00
AIRLOOP F4 N2 DXAC HEAT PUMP 0.136120 0.136120 0.136120 0.136120 2896.54 2896.54 1110.74 1.00
AIRLOOP F4 S1 DXAC HEAT PUMP 0.177539 0.177539 0.177539 0.177539 3540.03 3540.03 1110.74 1.00
AIRLOOP F4 S2 DXAC HEAT PUMP 0.178174 0.178174 0.178174 0.178174 3549.13 3549.13 1110.74 1.00
AIRLOOP M SW DXAC HEAT PUMP 0.293779 0.293779 0.293779 0.293779 5299.91 5299.91 1619.95 1.00
AIRLOOP M NW DXAC HEAT PUMP 0.274980 0.274980 0.274980 0.274980 5022.30 5022.30 1618.36 1.00
AIRLOOP M SE DXAC HEAT PUMP 0.260041 0.260041 0.260041 0.260041 4794.68 4794.68 1620.00 1.00
AIRLOOP M NE DXAC HEAT PUMP 0.232349 0.232349 0.232349 0.232349 4370.47 4370.47 1618.36 1.00
AIRLOOP M N1 DXAC HEAT PUMP 0.140215 0.140215 0.140215 0.140215 2967.41 2967.41 1110.74 1.00
AIRLOOP M N2 DXAC HEAT PUMP 0.139374 0.139374 0.139374 0.139374 2954.87 2954.87 1110.74 1.00
AIRLOOP M S1 DXAC HEAT PUMP 0.180068 0.180068 0.180068 0.180068 3587.83 3587.83 1110.74 1.00
AIRLOOP M S2 DXAC HEAT PUMP 0.180682 0.180682 0.180682 0.180682 3596.63 3596.63 1110.74 1.00
AIRLOOP F6 SW DXAC HEAT PUMP 0.289799 0.289799 0.289799 0.289799 5260.45 5260.45 1677.05 1.00
AIRLOOP F6 NW DXAC HEAT PUMP 0.271177 0.271177 0.271177 0.271177 4984.97 4984.97 1677.50 1.00
AIRLOOP F6 SE DXAC HEAT PUMP 0.256312 0.256312 0.256312 0.256312 4758.17 4758.17 1677.06 1.00
AIRLOOP F6 NE DXAC HEAT PUMP 0.228812 0.228812 0.228812 0.228812 4336.22 4336.22 1677.50 1.00
AIRLOOP F6 N1 DXAC HEAT PUMP 0.137427 0.137427 0.137427 0.137427 2934.90 2934.90 1110.74 1.00
AIRLOOP F6 N2 DXAC HEAT PUMP 0.136598 0.136598 0.136598 0.136598 2922.48 2922.48 1110.74 1.00
AIRLOOP F6 S1 DXAC HEAT PUMP 0.176704 0.176704 0.176704 0.176704 3548.68 3548.68 1110.74 1.00
AIRLOOP F6 S2 DXAC HEAT PUMP 0.177314 0.177314 0.177314 0.177314 3557.43 3557.43 1110.74 1.00
AIRLOOP F7 SW DXAC HEAT PUMP 0.288126 0.288126 0.288126 0.288126 5251.79 5251.79 1711.56 1.00
AIRLOOP F7 NW DXAC HEAT PUMP 0.269745 0.269745 0.269745 0.269745 4979.44 4979.44 1712.79 1.00
AIRLOOP F7 SE DXAC HEAT PUMP 0.254876 0.254876 0.254876 0.254876 4752.39 4752.39 1711.56 1.00
AIRLOOP F7 NE DXAC HEAT PUMP 0.227598 0.227598 0.227598 0.227598 4333.24 4333.24 1712.79 1.00
AIRLOOP F7 N1 DXAC HEAT PUMP 0.136796 0.136796 0.136796 0.136796 2933.17 2933.17 1110.74 1.00
AIRLOOP F7 N2 DXAC HEAT PUMP 0.135975 0.135975 0.135975 0.135975 2920.85 2920.85 1110.74 1.00
AIRLOOP F7 S1 DXAC HEAT PUMP 0.175531 0.175531 0.175531 0.175531 3540.03 3540.03 1110.74 1.00
AIRLOOP F7 S2 DXAC HEAT PUMP 0.176139 0.176139 0.176139 0.176139 3548.77 3548.77 1110.74 1.00
AIRLOOP F8 SW DXAC HEAT PUMP 0.287886 0.287886 0.287886 0.287886 5262.02 5262.02 1747.21 1.00
AIRLOOP F8 NW DXAC HEAT PUMP 0.269707 0.269707 0.269707 0.269707 4992.36 4992.36 1749.00 1.00
AIRLOOP F8 SE DXAC HEAT PUMP 0.254808 0.254808 0.254808 0.254808 4764.71 4764.71 1747.21 1.00
AIRLOOP F8 NE DXAC HEAT PUMP 0.227736 0.227736 0.227736 0.227736 4353.82 4353.82 1749.00 1.00
AIRLOOP F8 N1 DXAC HEAT PUMP 0.137465 0.137465 0.137465 0.137465 2949.97 2949.97 1110.74 1.00
AIRLOOP F8 N2 DXAC HEAT PUMP 0.136654 0.136654 0.136654 0.136654 2937.77 2937.77 1110.74 1.00
AIRLOOP F8 S1 DXAC HEAT PUMP 0.175673 0.175673 0.175673 0.175673 3549.61 3549.61 1110.74 1.00
AIRLOOP F8 S2 DXAC HEAT PUMP 0.176281 0.176281 0.176281 0.176281 3558.35 3558.35 1110.74 1.00
AIRLOOP F9 SW DXAC HEAT PUMP 0.295197 0.295197 0.295197 0.295197 5379.36 5379.36 1858.38 1.00
AIRLOOP F9 NW DXAC HEAT PUMP 0.277225 0.277225 0.277225 0.277225 5112.77 5112.77 1859.28 1.00
AIRLOOP F9 SE DXAC HEAT PUMP 0.258645 0.258645 0.258645 0.258645 4832.22 4832.22 1858.38 1.00
AIRLOOP F9 NE DXAC HEAT PUMP 0.231264 0.231264 0.231264 0.231264 4416.77 4416.77 1859.28 1.00
AIRLOOP F9 N1 DXAC HEAT PUMP 0.144860 0.144860 0.144860 0.144860 3066.27 3066.27 1186.34 1.00
AIRLOOP F9 N2 DXAC HEAT PUMP 0.144053 0.144053 0.144053 0.144053 3054.17 3054.17 1186.34 1.00
AIRLOOP F9 S1 DXAC HEAT PUMP 0.180689 0.180689 0.180689 0.180689 3629.65 3629.65 1185.33 1.00
AIRLOOP F9 S2 DXAC HEAT PUMP 0.181360 0.181360 0.181360 0.181360 3639.31 3639.31 1185.33 1.00
AIRLOOP T SW DXAC HEAT PUMP 0.353305 0.353305 0.353305 0.353305 6227.30 6227.30 2230.96 1.00
AIRLOOP T NW DXAC HEAT PUMP 0.331335 0.331335 0.331335 0.331335 5903.58 5903.58 2236.06 1.00
AIRLOOP T SE DXAC HEAT PUMP 0.307598 0.307598 0.307598 0.307598 5551.15 5551.15 2230.96 1.00
AIRLOOP T NE DXAC HEAT PUMP 0.271931 0.271931 0.271931 0.271931 5022.58 5022.58 2236.06 1.00
AIRLOOP T N1 DXAC HEAT PUMP 0.188188 0.188188 0.188188 0.188188 3746.82 3746.82 1590.70 1.00
AIRLOOP T N2 DXAC HEAT PUMP 0.188262 0.188262 0.188262 0.188262 3747.64 3747.64 1590.70 1.00
AIRLOOP T S1 DXAC HEAT PUMP 0.240158 0.240158 0.240158 0.240158 4494.04 4494.04 1584.65 1.00
AIRLOOP T S2 DXAC HEAT PUMP 0.240929 0.240929 0.240929 0.240929 4504.97 4504.97 1584.65 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
AIRLOOP G SW SUPPLY FAN 0.251203
AIRLOOP G NW SUPPLY FAN 0.233413
AIRLOOP OFFICE SUPPLY FAN 0.320355
AIRLOOP G NE SUPPLY FAN 0.193551
AIRLOOP G N1 SUPPLY FAN 0.107651
AIRLOOP G N2 SUPPLY FAN 0.106554
AIRLOOP G S1 SUPPLY FAN 0.147219
AIRLOOP G S2 SUPPLY FAN 0.151947
AIRLOOP F2 SW SUPPLY FAN 0.292889
AIRLOOP F2 NW SUPPLY FAN 0.272466
AIRLOOP F2 SE SUPPLY FAN 0.274566
AIRLOOP F2 NE SUPPLY FAN 0.228129
AIRLOOP F2 N1 SUPPLY FAN 0.133724
AIRLOOP F2 N2 SUPPLY FAN 0.132858
AIRLOOP F2 S1 SUPPLY FAN 0.175995
AIRLOOP F2 S2 SUPPLY FAN 0.177683
AIRLOOP F3 SW SUPPLY FAN 0.291996
AIRLOOP F3 NW SUPPLY FAN 0.272472
AIRLOOP F3 SE SUPPLY FAN 0.259502
AIRLOOP F3 NE SUPPLY FAN 0.229421
AIRLOOP F3 N1 SUPPLY FAN 0.135682
AIRLOOP F3 N2 SUPPLY FAN 0.134826
AIRLOOP F3 S1 SUPPLY FAN 0.177080
AIRLOOP F3 S2 SUPPLY FAN 0.177852
AIRLOOP F4 SW SUPPLY FAN 0.291733
AIRLOOP F4 NW SUPPLY FAN 0.272579
AIRLOOP F4 SE SUPPLY FAN 0.257952
AIRLOOP F4 NE SUPPLY FAN 0.229771
AIRLOOP F4 N1 SUPPLY FAN 0.136968
AIRLOOP F4 N2 SUPPLY FAN 0.136120
AIRLOOP F4 S1 SUPPLY FAN 0.177539
AIRLOOP F4 S2 SUPPLY FAN 0.178174
AIRLOOP M SW SUPPLY FAN 0.293779
AIRLOOP M NW SUPPLY FAN 0.274980
AIRLOOP M SE SUPPLY FAN 0.260041
AIRLOOP M NE SUPPLY FAN 0.232349
AIRLOOP M N1 SUPPLY FAN 0.140215
AIRLOOP M N2 SUPPLY FAN 0.139374
AIRLOOP M S1 SUPPLY FAN 0.180068
AIRLOOP M S2 SUPPLY FAN 0.180682
AIRLOOP F6 SW SUPPLY FAN 0.289799
AIRLOOP F6 NW SUPPLY FAN 0.271177
AIRLOOP F6 SE SUPPLY FAN 0.256312
AIRLOOP F6 NE SUPPLY FAN 0.228812
AIRLOOP F6 N1 SUPPLY FAN 0.137427
AIRLOOP F6 N2 SUPPLY FAN 0.136598
AIRLOOP F6 S1 SUPPLY FAN 0.176704
AIRLOOP F6 S2 SUPPLY FAN 0.177314
AIRLOOP F7 SW SUPPLY FAN 0.288126
AIRLOOP F7 NW SUPPLY FAN 0.269745
AIRLOOP F7 SE SUPPLY FAN 0.254876
AIRLOOP F7 NE SUPPLY FAN 0.227598
AIRLOOP F7 N1 SUPPLY FAN 0.136796
AIRLOOP F7 N2 SUPPLY FAN 0.135975
AIRLOOP F7 S1 SUPPLY FAN 0.175531
AIRLOOP F7 S2 SUPPLY FAN 0.176139
AIRLOOP F8 SW SUPPLY FAN 0.287886
AIRLOOP F8 NW SUPPLY FAN 0.269707
AIRLOOP F8 SE SUPPLY FAN 0.254808
AIRLOOP F8 NE SUPPLY FAN 0.227736
AIRLOOP F8 N1 SUPPLY FAN 0.137465
AIRLOOP F8 N2 SUPPLY FAN 0.136654
AIRLOOP F8 S1 SUPPLY FAN 0.175673
AIRLOOP F8 S2 SUPPLY FAN 0.176281
AIRLOOP F9 SW SUPPLY FAN 0.295197
AIRLOOP F9 NW SUPPLY FAN 0.277225
AIRLOOP F9 SE SUPPLY FAN 0.258645
AIRLOOP F9 NE SUPPLY FAN 0.231264
AIRLOOP F9 N1 SUPPLY FAN 0.144860
AIRLOOP F9 N2 SUPPLY FAN 0.144053
AIRLOOP F9 S1 SUPPLY FAN 0.180689
AIRLOOP F9 S2 SUPPLY FAN 0.181360
AIRLOOP T SW SUPPLY FAN 0.353305
AIRLOOP T NW SUPPLY FAN 0.331335
AIRLOOP T SE SUPPLY FAN 0.307598
AIRLOOP T NE SUPPLY FAN 0.271931
AIRLOOP T N1 SUPPLY FAN 0.188188
AIRLOOP T N2 SUPPLY FAN 0.188262
AIRLOOP T S1 SUPPLY FAN 0.240158
AIRLOOP T S2 SUPPLY FAN 0.240929


COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Heating Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP HEATING MODE AIRLOOP G SW 0.251203 4563.88 0.000100
HEAT PUMP HEATING MODE AIRLOOP G NW 0.233413 4297.11 0.000094
HEAT PUMP HEATING MODE AIRLOOP OFFICE 0.320355 5878.40 0.000128
HEAT PUMP HEATING MODE AIRLOOP G NE 0.193551 3688.42 0.000081
HEAT PUMP HEATING MODE AIRLOOP G N1 0.107651 2416.46 0.000053
HEAT PUMP HEATING MODE AIRLOOP G N2 0.106554 2399.94 0.000052
HEAT PUMP HEATING MODE AIRLOOP G S1 0.147219 3038.39 0.000066
HEAT PUMP HEATING MODE AIRLOOP G S2 0.151947 3106.59 0.000068
HEAT PUMP HEATING MODE AIRLOOP F2 SW 0.292889 5208.47 0.000114
HEAT PUMP HEATING MODE AIRLOOP F2 NW 0.272466 4908.76 0.000107
HEAT PUMP HEATING MODE AIRLOOP F2 SE 0.274566 4924.55 0.000108
HEAT PUMP HEATING MODE AIRLOOP F2 NE 0.228129 4234.91 0.000093
HEAT PUMP HEATING MODE AIRLOOP F2 N1 0.133724 2832.21 0.000062
HEAT PUMP HEATING MODE AIRLOOP F2 N2 0.132858 2819.34 0.000062
HEAT PUMP HEATING MODE AIRLOOP F2 S1 0.175995 3485.83 0.000076
HEAT PUMP HEATING MODE AIRLOOP F2 S2 0.177683 3510.09 0.000077
HEAT PUMP HEATING MODE AIRLOOP F3 SW 0.291996 5229.11 0.000114
HEAT PUMP HEATING MODE AIRLOOP F3 NW 0.272472 4941.72 0.000108
HEAT PUMP HEATING MODE AIRLOOP F3 SE 0.259502 4742.64 0.000104
HEAT PUMP HEATING MODE AIRLOOP F3 NE 0.229421 4285.20 0.000094
HEAT PUMP HEATING MODE AIRLOOP F3 N1 0.135682 2877.69 0.000063
HEAT PUMP HEATING MODE AIRLOOP F3 N2 0.134826 2864.95 0.000063
HEAT PUMP HEATING MODE AIRLOOP F3 S1 0.177080 3519.71 0.000077
HEAT PUMP HEATING MODE AIRLOOP F3 S2 0.177852 3530.77 0.000077
HEAT PUMP HEATING MODE AIRLOOP F4 SW 0.291733 5250.32 0.000115
HEAT PUMP HEATING MODE AIRLOOP F4 NW 0.272579 4967.87 0.000109
HEAT PUMP HEATING MODE AIRLOOP F4 SE 0.257952 4744.89 0.000104
HEAT PUMP HEATING MODE AIRLOOP F4 NE 0.229771 4314.05 0.000094
HEAT PUMP HEATING MODE AIRLOOP F4 N1 0.136968 2909.18 0.000064
HEAT PUMP HEATING MODE AIRLOOP F4 N2 0.136120 2896.54 0.000063
HEAT PUMP HEATING MODE AIRLOOP F4 S1 0.177539 3540.03 0.000077
HEAT PUMP HEATING MODE AIRLOOP F4 S2 0.178174 3549.13 0.000078
HEAT PUMP HEATING MODE AIRLOOP M SW 0.293779 5299.91 0.000116
HEAT PUMP HEATING MODE AIRLOOP M NW 0.274980 5022.30 0.000110
HEAT PUMP HEATING MODE AIRLOOP M SE 0.260041 4794.68 0.000105
HEAT PUMP HEATING MODE AIRLOOP M NE 0.232349 4370.47 0.000095
HEAT PUMP HEATING MODE AIRLOOP M N1 0.140215 2967.41 0.000065
HEAT PUMP HEATING MODE AIRLOOP M N2 0.139374 2954.87 0.000065
HEAT PUMP HEATING MODE AIRLOOP M S1 0.180068 3587.83 0.000078
HEAT PUMP HEATING MODE AIRLOOP M S2 0.180682 3596.63 0.000079
HEAT PUMP HEATING MODE AIRLOOP F6 SW 0.289799 5260.45 0.000115
HEAT PUMP HEATING MODE AIRLOOP F6 NW 0.271177 4984.97 0.000109
HEAT PUMP HEATING MODE AIRLOOP F6 SE 0.256312 4758.17 0.000104
HEAT PUMP HEATING MODE AIRLOOP F6 NE 0.228812 4336.22 0.000095
HEAT PUMP HEATING MODE AIRLOOP F6 N1 0.137427 2934.90 0.000064
HEAT PUMP HEATING MODE AIRLOOP F6 N2 0.136598 2922.48 0.000064
HEAT PUMP HEATING MODE AIRLOOP F6 S1 0.176704 3548.68 0.000078
HEAT PUMP HEATING MODE AIRLOOP F6 S2 0.177314 3557.43 0.000078
HEAT PUMP HEATING MODE AIRLOOP F7 SW 0.288126 5251.79 0.000115
HEAT PUMP HEATING MODE AIRLOOP F7 NW 0.269745 4979.44 0.000109
HEAT PUMP HEATING MODE AIRLOOP F7 SE 0.254876 4752.39 0.000104
HEAT PUMP HEATING MODE AIRLOOP F7 NE 0.227598 4333.24 0.000095
HEAT PUMP HEATING MODE AIRLOOP F7 N1 0.136796 2933.17 0.000064
HEAT PUMP HEATING MODE AIRLOOP F7 N2 0.135975 2920.85 0.000064
HEAT PUMP HEATING MODE AIRLOOP F7 S1 0.175531 3540.03 0.000077
HEAT PUMP HEATING MODE AIRLOOP F7 S2 0.176139 3548.77 0.000078
HEAT PUMP HEATING MODE AIRLOOP F8 SW 0.287886 5262.02 0.000115
HEAT PUMP HEATING MODE AIRLOOP F8 NW 0.269707 4992.36 0.000109
HEAT PUMP HEATING MODE AIRLOOP F8 SE 0.254808 4764.71 0.000104
HEAT PUMP HEATING MODE AIRLOOP F8 NE 0.227736 4353.82 0.000095
HEAT PUMP HEATING MODE AIRLOOP F8 N1 0.137465 2949.97 0.000064
HEAT PUMP HEATING MODE AIRLOOP F8 N2 0.136654 2937.77 0.000064
HEAT PUMP HEATING MODE AIRLOOP F8 S1 0.175673 3549.61 0.000078
HEAT PUMP HEATING MODE AIRLOOP F8 S2 0.176281 3558.35 0.000078
HEAT PUMP HEATING MODE AIRLOOP F9 SW 0.295197 5379.36 0.000118
HEAT PUMP HEATING MODE AIRLOOP F9 NW 0.277225 5112.77 0.000112
HEAT PUMP HEATING MODE AIRLOOP F9 SE 0.258645 4832.22 0.000106
HEAT PUMP HEATING MODE AIRLOOP F9 NE 0.231264 4416.77 0.000096
HEAT PUMP HEATING MODE AIRLOOP F9 N1 0.144860 3066.27 0.000067
HEAT PUMP HEATING MODE AIRLOOP F9 N2 0.144053 3054.17 0.000067
HEAT PUMP HEATING MODE AIRLOOP F9 S1 0.180689 3629.65 0.000079
HEAT PUMP HEATING MODE AIRLOOP F9 S2 0.181360 3639.31 0.000079
HEAT PUMP HEATING MODE AIRLOOP T SW 0.353305 6227.30 0.000136
HEAT PUMP HEATING MODE AIRLOOP T NW 0.331335 5903.58 0.000129
HEAT PUMP HEATING MODE AIRLOOP T SE 0.307598 5551.15 0.000121
HEAT PUMP HEATING MODE AIRLOOP T NE 0.271931 5022.58 0.000110
HEAT PUMP HEATING MODE AIRLOOP T N1 0.188188 3746.82 0.000082
HEAT PUMP HEATING MODE AIRLOOP T N2 0.188262 3747.64 0.000082
HEAT PUMP HEATING MODE AIRLOOP T S1 0.240158 4494.04 0.000098
HEAT PUMP HEATING MODE AIRLOOP T S2 0.240929 4504.97 0.000098


Coil:Heating:Electric

Nominal Capacity [W]
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW 1705.49
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW 1700.37
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE 2346.75
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE 1700.37
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 1197.34
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 1197.34
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 1200.38
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 1208.79
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW 1642.13
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW 1637.22
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE 1668.43
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE 1637.22
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW 1618.17
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW 1614.57
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE 1621.51
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE 1614.57
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW 1627.15
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW 1625.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE 1627.56
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE 1625.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW 1619.95
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW 1618.36
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE 1620.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE 1618.36
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW 1677.05
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW 1677.50
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE 1677.06
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE 1677.50
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW 1711.56
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW 1712.79
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE 1711.56
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE 1712.79
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW 1747.21
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW 1749.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE 1747.21
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE 1749.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 1110.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW 1858.38
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW 1859.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE 1858.38
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE 1859.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 1186.34
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 1186.34
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 1185.33
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 1185.33
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW 2230.96
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW 2236.06
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE 2230.96
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE 2236.06
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 1590.70
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 1590.70
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 1584.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 1584.65


PlantLoop

Maximum Loop Flow Rate [m3/s] Plant Loop Volume [m3]
SHWSYS1 0.000289 0.325214
SINGLE WATER PLANT LOOP 0.007150 8.04


Boiler:HotWater

Design Water Flow Rate [m3/s]
CENTRAL BOILER 0.007150


WaterHeater:Mixed

Use Side Design Flow Rate [m3/s]
SHWSYS1 WATER HEATER 0.000289


EvaporativeFluidCooler:SingleSpeed

Design Water Flow Rate [m3/s] Fan Power at Design Air Flow Rate [W] Design Air Flow Rate [m3/s] U-Factor Times Area Value at Design Air Flow Rate [W/C]
CENTRAL TOWER 0.007150 3451.82 9.09 10702.47


Pump:ConstantSpeed

Rated Flow Rate [m3/s] Rated Power Consumption [W]
SHWSYS1 PUMP 0.000289 36.93
PLANT CIRC PUMP 0.007150 1823.72



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW3 |
G WWALL SWA GWINDOW2 |
G NWALL NWA GWINDOW4 |
G WWALL NWA GWINDOW6 |
G SWALL SEA GWINDOW1 |
G EWALL SEA GWINDOW8 |
G NWALL NEA GWINDOW5 |
G EWALL NEA GWINDOW7 |
G NWALL N1A GWINDOW9 |
G NWALL N2A GWINDOW10 |
G SWALL S1A GWINDOW11 |
G SWALL S2A GWINDOW12 |
G WWALL C GWINDOW13 |
G EWALL C ENTRANCE DOOR |
F2 WWALL SWA F2WINDOW2 |
F2 SWALL SWA F2WINDOW3 |
F2 NWALL NWA F2WINDOW4 |
F2 WWALL NWA F2WINDOW6 |
F2 EWALL SEA F2WINDOW8 |
F2 SWALL SEA F2WINDOW1 |
F2 NWALL NEA F2WINDOW5 |
F2 EWALL NEA F2WINDOW7 |
F2 NWALL N1A F2WINDOW9 |
F2 NWALL N2A F2WINDOW10 |
F2 SWALL S1A F2WINDOW11 |
F2 SWALL S2A F2WINDOW12 |
F2 WWALL C F2WINDOW13 |
F2 EWALL C F2WINDOW14 |
F3 WWALL SWA F3WINDOW2 |
F3 SWALL SWA F3WINDOW3 |
F3 NWALL NWA F3WINDOW4 |
F3 WWALL NWA F3WINDOW6 |
F3 EWALL SEA F3WINDOW8 |
F3 SWALL SEA F3WINDOW1 |
F3 NWALL NEA F3WINDOW5 |
F3 EWALL NEA F3WINDOW7 |
F3 NWALL N1A F3WINDOW9 |
F3 NWALL N2A F3WINDOW10 |
F3 SWALL S1A F3WINDOW11 |
F3 SWALL S2A F3WINDOW12 |
F3 WWALL C F3WINDOW13 |
F3 EWALL C F3WINDOW14 |
F4 WWALL SWA F4WINDOW2 |
F4 SWALL SWA F4WINDOW3 |
F4 NWALL NWA F4WINDOW4 |
F4 WWALL NWA F4WINDOW6 |
F4 EWALL SEA F4WINDOW8 |
F4 SWALL SEA F4WINDOW1 |
F4 NWALL NEA F4WINDOW5 |
F4 EWALL NEA F4WINDOW7 |
F4 NWALL N1A F4WINDOW9 |
F4 NWALL N2A F4WINDOW10 |
F4 SWALL S1A F4WINDOW11 |
F4 SWALL S2A F4WINDOW12 |
F4 WWALL C F4WINDOW13 |
F4 EWALL C F4WINDOW14 |
M WWALL SWA MWINDOW2 |
M SWALL SWA MWINDOW3 |
M NWALL NWA MWINDOW4 |
M WWALL NWA MWINDOW6 |
M EWALL SEA MWINDOW8 |
M SWALL SEA MWINDOW1 |
M NWALL NEA MWINDOW5 |
M EWALL NEA MWINDOW7 |
M NWALL N1A MWINDOW9 |
M NWALL N2A MWINDOW10 |
M SWALL S1A MWINDOW11 |
M SWALL S2A MWINDOW12 |
M WWALL C MWINDOW13 |
M EWALL C MWINDOW14 |
F6 WWALL SWA F6WINDOW2 |
F6 SWALL SWA F6WINDOW3 |
F6 NWALL NWA F6WINDOW4 |
F6 WWALL NWA F6WINDOW6 |
F6 EWALL SEA F6WINDOW8 |
F6 SWALL SEA F6WINDOW1 |
F6 NWALL NEA F6WINDOW5 |
F6 EWALL NEA F6WINDOW7 |
F6 NWALL N1A F6WINDOW9 |
F6 NWALL N2A F6WINDOW10 |
F6 SWALL S1A F6WINDOW11 |
F6 SWALL S2A F6WINDOW12 |
F6 WWALL C F6WINDOW13 |
F6 EWALL C F6WINDOW14 |
F7 WWALL SWA F7WINDOW2 |
F7 SWALL SWA F7WINDOW3 |
F7 NWALL NWA F7WINDOW4 |
F7 WWALL NWA F7WINDOW6 |
F7 EWALL SEA F7WINDOW8 |
F7 SWALL SEA F7WINDOW1 |
F7 NWALL NEA F7WINDOW5 |
F7 EWALL NEA F7WINDOW7 |
F7 NWALL N1A F7WINDOW9 |
F7 NWALL N2A F7WINDOW10 |
F7 SWALL S1A F7WINDOW11 |
F7 SWALL S2A F7WINDOW12 |
F7 WWALL C F7WINDOW13 |
F7 EWALL C F7WINDOW14 |
F8 WWALL SWA F8WINDOW2 |
F8 SWALL SWA F8WINDOW3 |
F8 NWALL NWA F8WINDOW4 |
F8 WWALL NWA F8WINDOW6 |
F8 EWALL SEA F8WINDOW8 |
F8 SWALL SEA F8WINDOW1 |
F8 NWALL NEA F8WINDOW5 |
F8 EWALL NEA F8WINDOW7 |
F8 NWALL N1A F8WINDOW9 |
F8 NWALL N2A F8WINDOW10 |
F8 SWALL S1A F8WINDOW11 |
F8 SWALL S2A F8WINDOW12 |
F8 WWALL C F8WINDOW13 |
F8 EWALL C F8WINDOW14 |
F9 WWALL SWA F9WINDOW2 |
F9 SWALL SWA F9WINDOW3 |
F9 NWALL NWA F9WINDOW4 |
F9 WWALL NWA F9WINDOW6 |
F9 EWALL SEA F9WINDOW8 |
F9 SWALL SEA F9WINDOW1 |
F9 NWALL NEA F9WINDOW5 |
F9 EWALL NEA F9WINDOW7 |
F9 NWALL N1A F9WINDOW9 |
F9 NWALL N2A F9WINDOW10 |
F9 SWALL S1A F9WINDOW11 |
F9 SWALL S2A F9WINDOW12 |
F9 WWALL C F9WINDOW13 |
F9 EWALL C F9WINDOW14 |
T WWALL SWA TWINDOW2 |
T SWALL SWA TWINDOW3 |
T NWALL NWA TWINDOW4 |
T WWALL NWA TWINDOW6 |
T EWALL SEA TWINDOW8 |
T SWALL SEA TWINDOW1 |
T NWALL NEA TWINDOW5 |
T EWALL NEA TWINDOW7 |
T NWALL N1A TWINDOW9 |
T NWALL N2A TWINDOW10 |
T SWALL S1A TWINDOW11 |
T SWALL S2A TWINDOW12 |
T WWALL C TWINDOW13 |
T EWALL C TWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2018-10-19 09:40:08

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.22 13.57
February 23.37 15.49
March 23.41 17.07
April 24.02 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.26 24.23
November 23.88 18.91
December 23.42 15.68
     
Annual Sum or Average 23.97 21.89
Minimum of Months 23.22 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.55 13.57
February 22.89 15.49
March 23.18 17.07
April 23.96 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.19 24.23
November 23.48 18.91
December 22.87 15.68
     
Annual Sum or Average 23.76 21.89
Minimum of Months 22.55 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.26 13.57
February 23.53 15.49
March 23.64 17.07
April 24.16 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.31 24.23
November 23.95 18.91
December 23.49 15.68
     
Annual Sum or Average 24.03 21.89
Minimum of Months 23.26 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.48 13.57
February 22.83 15.49
March 23.17 17.07
April 23.94 21.23
May 24.40 26.90
June 24.40 27.61
July 24.41 27.94
August 24.40 27.43
September 24.40 26.23
October 24.18 24.23
November 23.46 18.91
December 22.80 15.68
     
Annual Sum or Average 23.74 21.89
Minimum of Months 22.48 13.57
Maximum of Months 24.41 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.35 13.57
February 22.67 15.49
March 23.00 17.07
April 23.81 21.23
May 24.40 26.90
June 24.41 27.61
July 24.44 27.94
August 24.42 27.43
September 24.41 26.23
October 24.15 24.23
November 23.31 18.91
December 22.70 15.68
     
Annual Sum or Average 23.68 21.89
Minimum of Months 22.35 13.57
Maximum of Months 24.44 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.35 13.57
February 22.67 15.49
March 23.00 17.07
April 23.81 21.23
May 24.40 26.90
June 24.41 27.61
July 24.45 27.94
August 24.42 27.43
September 24.41 26.23
October 24.15 24.23
November 23.31 18.91
December 22.70 15.68
     
Annual Sum or Average 23.68 21.89
Minimum of Months 22.35 13.57
Maximum of Months 24.45 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.28 13.57
February 23.37 15.49
March 23.39 17.07
April 23.96 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.42 26.23
October 24.28 24.23
November 23.93 18.91
December 23.49 15.68
     
Annual Sum or Average 23.98 21.89
Minimum of Months 23.28 13.57
Maximum of Months 24.42 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.29 13.57
February 23.39 15.49
March 23.41 17.07
April 23.97 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.42 26.23
October 24.28 24.23
November 23.95 18.91
December 23.51 15.68
     
Annual Sum or Average 23.99 21.89
Minimum of Months 23.29 13.57
Maximum of Months 24.42 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.67 13.57
February 21.42 15.49
March 22.03 17.07
April 23.81 21.23
May 25.96 26.90
June 26.78 27.61
July 26.88 27.94
August 26.73 27.43
September 26.25 26.23
October 25.09 24.23
November 22.89 18.91
December 21.49 15.68
     
Annual Sum or Average 24.18 21.89
Minimum of Months 20.67 13.57
Maximum of Months 26.88 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.76 13.57
February 23.87 15.49
March 23.85 17.07
April 24.29 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.36 24.23
November 24.26 18.91
December 23.89 15.68
     
Annual Sum or Average 24.19 21.89
Minimum of Months 23.76 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.91 13.57
February 23.33 15.49
March 23.60 17.07
April 24.25 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.30 24.23
November 23.94 18.91
December 23.24 15.68
     
Annual Sum or Average 23.97 21.89
Minimum of Months 22.91 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.79 13.57
February 23.91 15.49
March 23.90 17.07
April 24.31 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.37 24.23
November 24.28 18.91
December 23.90 15.68
     
Annual Sum or Average 24.21 21.89
Minimum of Months 23.79 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.84 13.57
February 23.29 15.49
March 23.58 17.07
April 24.25 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.28 24.23
November 23.92 18.91
December 23.15 15.68
     
Annual Sum or Average 23.94 21.89
Minimum of Months 22.84 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.77 13.57
February 23.21 15.49
March 23.50 17.07
April 24.19 21.23
May 24.41 26.90
June 24.42 27.61
July 24.44 27.94
August 24.42 27.43
September 24.41 26.23
October 24.28 24.23
November 23.86 18.91
December 23.14 15.68
     
Annual Sum or Average 23.92 21.89
Minimum of Months 22.77 13.57
Maximum of Months 24.44 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.77 13.57
February 23.20 15.49
March 23.50 17.07
April 24.19 21.23
May 24.41 26.90
June 24.42 27.61
July 24.45 27.94
August 24.42 27.43
September 24.42 26.23
October 24.28 24.23
November 23.85 18.91
December 23.13 15.68
     
Annual Sum or Average 23.92 21.89
Minimum of Months 22.77 13.57
Maximum of Months 24.45 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.94 13.57
February 23.96 15.49
March 23.90 17.07
April 24.27 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.42 26.23
October 24.41 24.23
November 24.33 18.91
December 24.04 15.68
     
Annual Sum or Average 24.24 21.89
Minimum of Months 23.90 13.57
Maximum of Months 24.42 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.94 13.57
February 23.97 15.49
March 23.91 17.07
April 24.27 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.41 26.23
October 24.41 24.23
November 24.33 18.91
December 24.04 15.68
     
Annual Sum or Average 24.24 21.89
Minimum of Months 23.91 13.57
Maximum of Months 24.41 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 CORRIDOR

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.31 13.57
February 24.70 15.49
March 24.91 17.07
April 25.83 21.23
May 26.44 26.90
June 26.67 27.61
July 26.70 27.94
August 26.66 27.43
September 26.54 26.23
October 26.22 24.23
November 25.48 18.91
December 24.68 15.68
     
Annual Sum or Average 25.77 21.89
Minimum of Months 24.31 13.57
Maximum of Months 26.70 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.85 13.57
February 23.94 15.49
March 23.90 17.07
April 24.32 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.36 24.23
November 24.30 18.91
December 23.96 15.68
     
Annual Sum or Average 24.22 21.89
Minimum of Months 23.85 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.98 13.57
February 23.41 15.49
March 23.66 17.07
April 24.29 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.31 24.23
November 24.03 18.91
December 23.33 15.68
     
Annual Sum or Average 24.00 21.89
Minimum of Months 22.98 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.84 13.57
February 23.93 15.49
March 23.91 17.07
April 24.32 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.41 26.23
October 24.39 24.23
November 24.31 18.91
December 23.94 15.68
     
Annual Sum or Average 24.22 21.89
Minimum of Months 23.84 13.57
Maximum of Months 24.41 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.92 13.57
February 23.38 15.49
March 23.65 17.07
April 24.28 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.29 24.23
November 24.01 18.91
December 23.23 15.68
     
Annual Sum or Average 23.98 21.89
Minimum of Months 22.92 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.91 13.57
February 23.34 15.49
March 23.62 17.07
April 24.25 21.23
May 24.42 26.90
June 24.42 27.61
July 24.45 27.94
August 24.43 27.43
September 24.42 26.23
October 24.30 24.23
November 23.99 18.91
December 23.29 15.68
     
Annual Sum or Average 23.99 21.89
Minimum of Months 22.91 13.57
Maximum of Months 24.45 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.90 13.57
February 23.34 15.49
March 23.62 17.07
April 24.25 21.23
May 24.42 26.90
June 24.42 27.61
July 24.45 27.94
August 24.43 27.43
September 24.42 26.23
October 24.30 24.23
November 23.99 18.91
December 23.28 15.68
     
Annual Sum or Average 23.99 21.89
Minimum of Months 22.90 13.57
Maximum of Months 24.45 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.06 13.57
February 24.06 15.49
March 23.99 17.07
April 24.31 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.42 26.23
October 24.43 24.23
November 24.38 18.91
December 24.14 15.68
     
Annual Sum or Average 24.28 21.89
Minimum of Months 23.99 13.57
Maximum of Months 24.43 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.06 13.57
February 24.06 15.49
March 23.99 17.07
April 24.31 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.42 26.23
October 24.43 24.23
November 24.38 18.91
December 24.14 15.68
     
Annual Sum or Average 24.28 21.89
Minimum of Months 23.99 13.57
Maximum of Months 24.43 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 CORRIDOR

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.77 13.57
February 25.14 15.49
March 25.30 17.07
April 26.15 21.23
May 26.62 26.90
June 26.73 27.61
July 26.74 27.94
August 26.70 27.43
September 26.61 26.23
October 26.43 24.23
November 25.86 18.91
December 25.11 15.68
     
Annual Sum or Average 26.02 21.89
Minimum of Months 24.77 13.57
Maximum of Months 26.74 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.86 13.57
February 23.94 15.49
March 23.89 17.07
April 24.32 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.36 24.23
November 24.31 18.91
December 23.96 15.68
     
Annual Sum or Average 24.22 21.89
Minimum of Months 23.86 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.98 13.57
February 23.42 15.49
March 23.66 17.07
April 24.29 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.30 24.23
November 24.05 18.91
December 23.34 15.68
     
Annual Sum or Average 24.00 21.89
Minimum of Months 22.98 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.84 13.57
February 23.92 15.49
March 23.90 17.07
April 24.32 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.41 26.23
October 24.39 24.23
November 24.31 18.91
December 23.93 15.68
     
Annual Sum or Average 24.22 21.89
Minimum of Months 23.84 13.57
Maximum of Months 24.41 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.92 13.57
February 23.39 15.49
March 23.65 17.07
April 24.28 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.29 24.23
November 24.03 18.91
December 23.24 15.68
     
Annual Sum or Average 23.99 21.89
Minimum of Months 22.92 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.94 13.57
February 23.38 15.49
March 23.64 17.07
April 24.26 21.23
May 24.42 26.90
June 24.42 27.61
July 24.45 27.94
August 24.43 27.43
September 24.42 26.23
October 24.30 24.23
November 24.02 18.91
December 23.32 15.68
     
Annual Sum or Average 24.00 21.89
Minimum of Months 22.94 13.57
Maximum of Months 24.45 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.93 13.57
February 23.37 15.49
March 23.64 17.07
April 24.26 21.23
May 24.42 26.90
June 24.42 27.61
July 24.45 27.94
August 24.43 27.43
September 24.42 26.23
October 24.30 24.23
November 24.02 18.91
December 23.31 15.68
     
Annual Sum or Average 24.00 21.89
Minimum of Months 22.93 13.57
Maximum of Months 24.45 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.07 13.57
February 24.07 15.49
March 24.00 17.07
April 24.31 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.42 26.23
October 24.43 24.23
November 24.38 18.91
December 24.15 15.68
     
Annual Sum or Average 24.29 21.89
Minimum of Months 24.00 13.57
Maximum of Months 24.43 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.07 13.57
February 24.07 15.49
March 24.00 17.07
April 24.31 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.42 26.23
October 24.43 24.23
November 24.38 18.91
December 24.15 15.68
     
Annual Sum or Average 24.29 21.89
Minimum of Months 24.00 13.57
Maximum of Months 24.43 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 CORRIDOR

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.93 13.57
February 25.30 15.49
March 25.44 17.07
April 26.28 21.23
May 26.73 26.90
June 26.82 27.61
July 26.83 27.94
August 26.78 27.43
September 26.69 26.23
October 26.54 24.23
November 26.01 18.91
December 25.26 15.68
     
Annual Sum or Average 26.14 21.89
Minimum of Months 24.93 13.57
Maximum of Months 26.83 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.85 13.57
February 23.93 15.49
March 23.88 17.07
April 24.32 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.36 24.23
November 24.31 18.91
December 23.96 15.68
     
Annual Sum or Average 24.22 21.89
Minimum of Months 23.85 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.98 13.57
February 23.43 15.49
March 23.66 17.07
April 24.29 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.30 24.23
November 24.05 18.91
December 23.34 15.68
     
Annual Sum or Average 24.01 21.89
Minimum of Months 22.98 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.83 13.57
February 23.91 15.49
March 23.89 17.07
April 24.32 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.41 26.23
October 24.39 24.23
November 24.31 18.91
December 23.93 15.68
     
Annual Sum or Average 24.22 21.89
Minimum of Months 23.83 13.57
Maximum of Months 24.41 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.92 13.57
February 23.40 15.49
March 23.65 17.07
April 24.29 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.29 24.23
November 24.04 18.91
December 23.24 15.68
     
Annual Sum or Average 23.99 21.89
Minimum of Months 22.92 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.96 13.57
February 23.40 15.49
March 23.65 17.07
April 24.26 21.23
May 24.42 26.90
June 24.42 27.61
July 24.45 27.94
August 24.43 27.43
September 24.42 26.23
October 24.30 24.23
November 24.04 18.91
December 23.34 15.68
     
Annual Sum or Average 24.01 21.89
Minimum of Months 22.96 13.57
Maximum of Months 24.45 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.95 13.57
February 23.39 15.49
March 23.65 17.07
April 24.26 21.23
May 24.42 26.90
June 24.42 27.61
July 24.45 27.94
August 24.43 27.43
September 24.42 26.23
October 24.30 24.23
November 24.04 18.91
December 23.33 15.68
     
Annual Sum or Average 24.01 21.89
Minimum of Months 22.95 13.57
Maximum of Months 24.45 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.08 13.57
February 24.07 15.49
March 23.99 17.07
April 24.31 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.41 27.43
September 24.42 26.23
October 24.43 24.23
November 24.38 18.91
December 24.15 15.68
     
Annual Sum or Average 24.29 21.89
Minimum of Months 23.99 13.57
Maximum of Months 24.43 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.08 13.57
February 24.07 15.49
March 24.00 17.07
April 24.31 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.42 26.23
October 24.43 24.23
November 24.38 18.91
December 24.15 15.68
     
Annual Sum or Average 24.29 21.89
Minimum of Months 24.00 13.57
Maximum of Months 24.43 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 25.55 13.57
February 25.91 15.49
March 26.05 17.07
April 26.88 21.23
May 27.32 26.90
June 27.40 27.61
July 27.41 27.94
August 27.37 27.43
September 27.28 26.23
October 27.13 24.23
November 26.62 18.91
December 25.88 15.68
     
Annual Sum or Average 26.74 21.89
Minimum of Months 25.55 13.57
Maximum of Months 27.41 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.79 13.57
February 23.88 15.49
March 23.84 17.07
April 24.31 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.35 24.23
November 24.29 18.91
December 23.91 15.68
     
Annual Sum or Average 24.20 21.89
Minimum of Months 23.79 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.91 13.57
February 23.37 15.49
March 23.60 17.07
April 24.27 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.28 24.23
November 24.00 18.91
December 23.25 15.68
     
Annual Sum or Average 23.97 21.89
Minimum of Months 22.91 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.77 13.57
February 23.86 15.49
March 23.84 17.07
April 24.31 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.41 26.23
October 24.38 24.23
November 24.29 18.91
December 23.87 15.68
     
Annual Sum or Average 24.20 21.89
Minimum of Months 23.77 13.57
Maximum of Months 24.41 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.84 13.57
February 23.34 15.49
March 23.59 17.07
April 24.27 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.27 24.23
November 23.98 18.91
December 23.16 15.68
     
Annual Sum or Average 23.96 21.89
Minimum of Months 22.84 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.88 13.57
February 23.34 15.49
March 23.59 17.07
April 24.24 21.23
May 24.42 26.90
June 24.42 27.61
July 24.45 27.94
August 24.43 27.43
September 24.42 26.23
October 24.29 24.23
November 23.98 18.91
December 23.25 15.68
     
Annual Sum or Average 23.98 21.89
Minimum of Months 22.88 13.57
Maximum of Months 24.45 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.87 13.57
February 23.33 15.49
March 23.58 17.07
April 24.24 21.23
May 24.42 26.90
June 24.42 27.61
July 24.45 27.94
August 24.43 27.43
September 24.42 26.23
October 24.29 24.23
November 23.98 18.91
December 23.24 15.68
     
Annual Sum or Average 23.98 21.89
Minimum of Months 22.87 13.57
Maximum of Months 24.45 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.03 13.57
February 24.03 15.49
March 23.95 17.07
April 24.30 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.41 27.43
September 24.42 26.23
October 24.43 24.23
November 24.37 18.91
December 24.11 15.68
     
Annual Sum or Average 24.27 21.89
Minimum of Months 23.95 13.57
Maximum of Months 24.43 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.03 13.57
February 24.03 15.49
March 23.95 17.07
April 24.30 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.41 27.43
September 24.42 26.23
October 24.43 24.23
November 24.37 18.91
December 24.11 15.68
     
Annual Sum or Average 24.27 21.89
Minimum of Months 23.95 13.57
Maximum of Months 24.43 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 CORRIDOR

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.86 13.57
February 25.24 15.49
March 25.38 17.07
April 26.26 21.23
May 26.72 26.90
June 26.81 27.61
July 26.82 27.94
August 26.77 27.43
September 26.68 26.23
October 26.51 24.23
November 25.98 18.91
December 25.20 15.68
     
Annual Sum or Average 26.11 21.89
Minimum of Months 24.86 13.57
Maximum of Months 26.82 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.74 13.57
February 23.84 15.49
March 23.80 17.07
April 24.30 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.35 24.23
November 24.28 18.91
December 23.87 15.68
     
Annual Sum or Average 24.18 21.89
Minimum of Months 23.74 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.85 13.57
February 23.32 15.49
March 23.56 17.07
April 24.26 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.27 24.23
November 23.96 18.91
December 23.19 15.68
     
Annual Sum or Average 23.95 21.89
Minimum of Months 22.85 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.72 13.57
February 23.82 15.49
March 23.81 17.07
April 24.30 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.41 26.23
October 24.37 24.23
November 24.28 18.91
December 23.83 15.68
     
Annual Sum or Average 24.18 21.89
Minimum of Months 23.72 13.57
Maximum of Months 24.41 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.79 13.57
February 23.29 15.49
March 23.55 17.07
April 24.25 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.26 24.23
November 23.94 18.91
December 23.10 15.68
     
Annual Sum or Average 23.94 21.89
Minimum of Months 22.79 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.82 13.57
February 23.29 15.49
March 23.54 17.07
April 24.23 21.23
May 24.42 26.90
June 24.42 27.61
July 24.45 27.94
August 24.43 27.43
September 24.42 26.23
October 24.28 24.23
November 23.94 18.91
December 23.19 15.68
     
Annual Sum or Average 23.96 21.89
Minimum of Months 22.82 13.57
Maximum of Months 24.45 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.81 13.57
February 23.29 15.49
March 23.54 17.07
April 24.23 21.23
May 24.42 26.90
June 24.42 27.61
July 24.45 27.94
August 24.43 27.43
September 24.43 26.23
October 24.28 24.23
November 23.94 18.91
December 23.18 15.68
     
Annual Sum or Average 23.95 21.89
Minimum of Months 22.81 13.57
Maximum of Months 24.45 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.99 13.57
February 23.99 15.49
March 23.91 17.07
April 24.29 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.41 27.43
September 24.42 26.23
October 24.43 24.23
November 24.36 18.91
December 24.08 15.68
     
Annual Sum or Average 24.26 21.89
Minimum of Months 23.91 13.57
Maximum of Months 24.43 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.99 13.57
February 23.99 15.49
March 23.91 17.07
April 24.29 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.41 27.43
September 24.42 26.23
October 24.43 24.23
November 24.36 18.91
December 24.07 15.68
     
Annual Sum or Average 24.26 21.89
Minimum of Months 23.91 13.57
Maximum of Months 24.43 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 CORRIDOR

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.71 13.57
February 25.10 15.49
March 25.24 17.07
April 26.16 21.23
May 26.64 26.90
June 26.73 27.61
July 26.74 27.94
August 26.69 27.43
September 26.60 26.23
October 26.42 24.23
November 25.86 18.91
December 25.05 15.68
     
Annual Sum or Average 26.00 21.89
Minimum of Months 24.71 13.57
Maximum of Months 26.74 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.69 13.57
February 23.81 15.49
March 23.77 17.07
April 24.29 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.34 24.23
November 24.27 18.91
December 23.83 15.68
     
Annual Sum or Average 24.17 21.89
Minimum of Months 23.69 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.81 13.57
February 23.29 15.49
March 23.53 17.07
April 24.25 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.26 24.23
November 23.92 18.91
December 23.14 15.68
     
Annual Sum or Average 23.93 21.89
Minimum of Months 22.81 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.67 13.57
February 23.78 15.49
March 23.77 17.07
April 24.29 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.41 26.23
October 24.37 24.23
November 24.27 18.91
December 23.79 15.68
     
Annual Sum or Average 24.16 21.89
Minimum of Months 23.67 13.57
Maximum of Months 24.41 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.75 13.57
February 23.26 15.49
March 23.52 17.07
April 24.24 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.24 24.23
November 23.90 18.91
December 23.06 15.68
     
Annual Sum or Average 23.92 21.89
Minimum of Months 22.75 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.77 13.57
February 23.25 15.49
March 23.50 17.07
April 24.21 21.23
May 24.42 26.90
June 24.42 27.61
July 24.45 27.94
August 24.43 27.43
September 24.42 26.23
October 24.27 24.23
November 23.90 18.91
December 23.14 15.68
     
Annual Sum or Average 23.94 21.89
Minimum of Months 22.77 13.57
Maximum of Months 24.45 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.77 13.57
February 23.25 15.49
March 23.50 17.07
April 24.21 21.23
May 24.43 26.90
June 24.42 27.61
July 24.45 27.94
August 24.43 27.43
September 24.43 26.23
October 24.27 24.23
November 23.90 18.91
December 23.13 15.68
     
Annual Sum or Average 23.93 21.89
Minimum of Months 22.77 13.57
Maximum of Months 24.45 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.95 13.57
February 23.96 15.49
March 23.87 17.07
April 24.28 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.41 27.43
September 24.42 26.23
October 24.42 24.23
November 24.35 18.91
December 24.04 15.68
     
Annual Sum or Average 24.24 21.89
Minimum of Months 23.87 13.57
Maximum of Months 24.42 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.95 13.57
February 23.96 15.49
March 23.87 17.07
April 24.28 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.41 27.43
September 24.42 26.23
October 24.42 24.23
November 24.35 18.91
December 24.04 15.68
     
Annual Sum or Average 24.24 21.89
Minimum of Months 23.87 13.57
Maximum of Months 24.42 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 CORRIDOR

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.62 13.57
February 25.03 15.49
March 25.18 17.07
April 26.13 21.23
May 26.64 26.90
June 26.73 27.61
July 26.74 27.94
August 26.70 27.43
September 26.60 26.23
October 26.40 24.23
November 25.81 18.91
December 24.98 15.68
     
Annual Sum or Average 25.97 21.89
Minimum of Months 24.62 13.57
Maximum of Months 26.74 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.62 13.57
February 23.76 15.49
March 23.73 17.07
April 24.28 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.33 24.23
November 24.24 18.91
December 23.77 15.68
     
Annual Sum or Average 24.15 21.89
Minimum of Months 23.62 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.77 13.57
February 23.26 15.49
March 23.49 17.07
April 24.23 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.24 24.23
November 23.87 18.91
December 23.09 15.68
     
Annual Sum or Average 23.91 21.89
Minimum of Months 22.77 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.60 13.57
February 23.73 15.49
March 23.73 17.07
April 24.27 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.41 26.23
October 24.35 24.23
November 24.24 18.91
December 23.73 15.68
     
Annual Sum or Average 24.14 21.89
Minimum of Months 23.60 13.57
Maximum of Months 24.41 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.70 13.57
February 23.22 15.49
March 23.47 17.07
April 24.23 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.23 24.23
November 23.85 18.91
December 23.00 15.68
     
Annual Sum or Average 23.89 21.89
Minimum of Months 22.70 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.73 13.57
February 23.22 15.49
March 23.46 17.07
April 24.20 21.23
May 24.42 26.90
June 24.42 27.61
July 24.44 27.94
August 24.43 27.43
September 24.42 26.23
October 24.25 24.23
November 23.85 18.91
December 23.07 15.68
     
Annual Sum or Average 23.91 21.89
Minimum of Months 22.73 13.57
Maximum of Months 24.44 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.72 13.57
February 23.21 15.49
March 23.46 17.07
April 24.20 21.23
May 24.42 26.90
June 24.42 27.61
July 24.44 27.94
August 24.43 27.43
September 24.42 26.23
October 24.25 24.23
November 23.85 18.91
December 23.06 15.68
     
Annual Sum or Average 23.91 21.89
Minimum of Months 22.72 13.57
Maximum of Months 24.44 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.87 13.57
February 23.90 15.49
March 23.82 17.07
April 24.27 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.41 27.43
September 24.42 26.23
October 24.41 24.23
November 24.33 18.91
December 23.97 15.68
     
Annual Sum or Average 24.22 21.89
Minimum of Months 23.82 13.57
Maximum of Months 24.42 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.87 13.57
February 23.90 15.49
March 23.82 17.07
April 24.27 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.41 27.43
September 24.42 26.23
October 24.40 24.23
November 24.33 18.91
December 23.97 15.68
     
Annual Sum or Average 24.22 21.89
Minimum of Months 23.82 13.57
Maximum of Months 24.42 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 CORRIDOR

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.51 13.57
February 24.96 15.49
March 25.12 17.07
April 26.15 21.23
May 26.73 26.90
June 26.84 27.61
July 26.85 27.94
August 26.79 27.43
September 26.68 26.23
October 26.44 24.23
November 25.76 18.91
December 24.88 15.68
     
Annual Sum or Average 25.98 21.89
Minimum of Months 24.51 13.57
Maximum of Months 26.85 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.35 13.57
February 23.57 15.49
March 23.56 17.07
April 24.17 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.27 24.23
November 24.02 18.91
December 23.53 15.68
     
Annual Sum or Average 24.04 21.89
Minimum of Months 23.35 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.76 13.57
February 23.18 15.49
March 23.37 17.07
April 24.13 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.19 24.23
November 23.69 18.91
December 23.02 15.68
     
Annual Sum or Average 23.86 21.89
Minimum of Months 22.76 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.34 13.57
February 23.54 15.49
March 23.57 17.07
April 24.17 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.41 26.23
October 24.28 24.23
November 24.01 18.91
December 23.50 15.68
     
Annual Sum or Average 24.04 21.89
Minimum of Months 23.34 13.57
Maximum of Months 24.41 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.67 13.57
February 23.13 15.49
March 23.35 17.07
April 24.12 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.40 26.23
October 24.17 24.23
November 23.66 18.91
December 22.93 15.68
     
Annual Sum or Average 23.84 21.89
Minimum of Months 22.67 13.57
Maximum of Months 24.40 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.67 13.57
February 23.11 15.49
March 23.34 17.07
April 24.10 21.23
May 24.40 26.90
June 24.40 27.61
July 24.42 27.94
August 24.41 27.43
September 24.41 26.23
October 24.19 24.23
November 23.65 18.91
December 22.96 15.68
     
Annual Sum or Average 23.84 21.89
Minimum of Months 22.67 13.57
Maximum of Months 24.42 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.67 13.57
February 23.11 15.49
March 23.34 17.07
April 24.10 21.23
May 24.40 26.90
June 24.40 27.61
July 24.42 27.94
August 24.41 27.43
September 24.41 26.23
October 24.18 24.23
November 23.65 18.91
December 22.95 15.68
     
Annual Sum or Average 23.84 21.89
Minimum of Months 22.67 13.57
Maximum of Months 24.42 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.51 13.57
February 23.67 15.49
March 23.65 17.07
April 24.18 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.41 26.23
October 24.31 24.23
November 24.14 18.91
December 23.69 15.68
     
Annual Sum or Average 24.10 21.89
Minimum of Months 23.51 13.57
Maximum of Months 24.41 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.51 13.57
February 23.67 15.49
March 23.65 17.07
April 24.18 21.23
May 24.40 26.90
June 24.40 27.61
July 24.40 27.94
August 24.40 27.43
September 24.41 26.23
October 24.31 24.23
November 24.14 18.91
December 23.68 15.68
     
Annual Sum or Average 24.10 21.89
Minimum of Months 23.51 13.57
Maximum of Months 24.41 27.94



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2018-10-19 09:40:08

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.73 13.57
February 25.26 15.49
March 25.50 17.07
April 26.74 21.23
May 27.58 26.90
June 27.75 27.61
July 27.74 27.94
August 27.66 27.43
September 27.47 26.23
October 27.11 24.23
November 26.13 18.91
December 25.15 15.68
     
Annual Sum or Average 26.57 21.89
Minimum of Months 24.73 13.57
Maximum of Months 27.75 27.94



Table of Contents

Report: COMPONENTS OF PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2018-10-19 09:40:08

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY {AT MAX/MIN} [W] HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W]
January 0.231867E+12 152510.249 19-JAN-16:15 16050.792 44912.182 19155.517 0.000 66887.339 0.000 1860.651 2826.554 0.000 0.000 0.000 0.000 0.000 0.000 0.000
February 0.217620E+12 161143.394 27-FEB-17:15 18221.747 56933.809 19155.517 0.000 61194.596 0.000 1860.651 2628.770 0.000 0.000 0.000 0.000 0.000 0.000 0.000
March 0.244893E+12 172656.476 28-MAR-16:15 18221.747 56933.809 19155.517 0.000 72268.538 0.000 1860.651 3067.910 0.000 0.000 0.000 0.000 0.000 0.000 0.000
April 0.267494E+12 188302.809 29-APR-18:00 25049.151 51564.864 19155.517 0.000 75843.039 10720.100 1860.651 3094.873 0.000 0.000 0.000 0.000 0.000 0.000 0.000
May 0.352063E+12 185060.184 23-MAY-17:15 22204.399 56867.515 19155.517 0.000 80401.017 0.000 1860.651 3425.449 0.000 0.000 0.000 0.000 0.000 0.000 0.000
June 0.346491E+12 183051.652 28-JUN-17:30 22204.399 56867.515 19155.517 0.000 78386.720 0.000 1860.651 3430.961 0.000 0.000 0.000 0.000 0.000 0.000 0.000
July 0.368671E+12 187110.696 22-JUL-17:15 22204.399 56867.515 19155.517 0.000 82425.161 0.000 1860.651 3451.817 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 0.365779E+12 195062.843 10-AUG-19:00 25049.151 49704.829 19155.517 0.000 84175.206 10720.100 1860.651 3451.817 0.000 0.000 0.000 0.000 0.000 0.000 0.000
September 0.346704E+12 191315.892 12-SEP-18:00 25049.151 51564.864 19155.517 0.000 78654.949 10720.100 1860.651 3296.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000
October 0.327850E+12 191681.914 08-OCT-18:00 25049.151 51564.864 19155.517 0.000 79047.938 10720.100 1860.651 3269.079 0.000 0.000 0.000 0.000 0.000 0.000 0.000
November 0.255206E+12 181810.568 07-NOV-18:30 22204.399 56867.515 19155.517 0.000 66755.646 10720.100 1860.651 3100.851 0.000 0.000 0.000 0.000 0.000 0.000 0.000
December 0.245846E+12 168482.005 15-DEC-18:15 22204.399 56867.515 19155.517 0.000 53975.474 10720.100 1860.651 2552.713 0.000 0.000 0.000 0.000 0.000 0.000 0.000
                                     
Annual Sum or Average 0.357048E+13                     0.000 0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.217620E+12 152510.249   16050.792 44912.182 19155.517 0.000 53975.474 0.000 1860.651 2552.713 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.368671E+12 195062.843   25049.151 56933.809 19155.517 0.000 84175.206 10720.100 1860.651 3451.817 0.000 0.000 0.000 0.000 0.000 0.000 0.000



Table of Contents

Report: COMPONENTS OF PEAK GAS DEMAND

For: Meter

Timestamp: 2018-10-19 09:40:08

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC [Invalid/Undefined] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT {AT MAX/MIN} [W] WATERSYSTEMS:GAS {AT MAX/MIN} [W] WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] HEATING:GAS {AT MAX/MIN} [W]
January 0.891285E+11 121593.422 10-JAN-07:15 0.000 0.000 0.000 121593.422 79136.664 79136.664 42456.759
February 0.823044E+11 179729.284 05-FEB-07:15 0.000 0.000 0.000 179729.284 79131.819 79131.819 100597.464
March 0.851199E+11 111167.491 11-MAR-09:00 0.000 0.000 0.000 111167.491 74323.954 74323.954 36843.537
April 0.749565E+11 78140.879 01-APR-06:45 0.000 0.000 0.000 78140.879 78140.879 78140.879 0.000
May 0.720493E+11 76513.918 01-MAY-06:30 0.000 0.000 0.000 76513.918 76513.918 76513.918 0.000
June 0.655206E+11 72605.711 04-JUN-06:45 0.000 0.000 0.000 72605.711 72605.711 72605.711 0.000
July 0.655564E+11 69438.975 01-JUL-06:00 0.000 0.000 0.000 69438.975 69438.975 69438.975 0.000
August 0.662628E+11 71323.039 31-AUG-06:30 0.000 0.000 0.000 71323.039 71323.039 71323.039 0.000
September 0.673080E+11 75881.270 30-SEP-06:00 0.000 0.000 0.000 75881.270 75881.270 75881.270 0.000
October 0.746018E+11 77276.143 29-OCT-06:00 0.000 0.000 0.000 77276.143 77276.143 77276.143 0.000
November 0.773699E+11 78626.986 29-NOV-07:30 0.000 0.000 0.000 78626.986 78626.986 78626.986 0.000
December 0.870332E+11 144561.388 20-DEC-06:00 0.000 0.000 0.000 144561.388 77385.227 77385.227 67176.161
                     
Annual Sum or Average 0.907211E+12     0.000 0.000 0.000        
Minimum of Months 0.655206E+11 69438.975   0.000 0.000 0.000 69438.975 69438.975 69438.975 0.000
Maximum of Months 0.891285E+11 179729.284   0.000 0.000 0.000 179729.284 79136.664 79136.664 100597.464