Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:37
Tabular Output Report in Format: HTML
Building: High-Rise Apartment
Environment: International Falls Intl Ap MN USA TMY3 WMO#=727470
Simulation Timestamp: 2018-10-19 09:40:12
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:12
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 5978.59 | 762.92 | 846.84 |
Net Site Energy | 5978.59 | 762.92 | 846.84 |
Total Source Energy | 12796.62 | 1632.95 | 1812.58 |
Net Source Energy | 12796.62 | 1632.95 | 1812.58 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 7836.48 |
Net Conditioned Building Area | 7059.89 |
Unconditioned Building Area | 776.58 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 415.05 | 1570.73 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 231.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 416.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 168.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1131.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 589.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 49.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 9.72 | 0.00 | 0.00 | 0.00 | 0.00 | 656.92 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 1375.77 | 0.00 | 0.00 | 0.00 | 4778.51 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 3032.08 | 2946.50 | 0.00 | 0.00 | 0.00 | 5435.43 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Boiler | 0.00 | 1570.73 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Other | 415.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 231.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 348.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 67.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 168.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 1131.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 589.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 49.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 9.72 | 0.00 | 0.00 | 0.00 | 0.00 | 656.92 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 1375.77 | 0.00 | 0.00 | 0.00 | 0.00 |
sub cat | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4778.51 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 82.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 183.49 | 417.36 | 0.00 | 0.00 | 0.00 | 0.77 |
Other | 160.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 429.48 | 417.36 | 0.00 | 0.00 | 0.00 | 0.77 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 74.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 165.31 | 376.00 | 0.00 | 0.00 | 0.00 | 0.69 |
Other | 144.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 386.92 | 376.00 | 0.00 | 0.00 | 0.00 | 0.69 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 3032.08 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 3032.08 | 100.00 |
Total On-Site and Utility Electric Sources | 3032.08 | 100.00 |
Total Electricity End Uses | 3032.08 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 5435.43 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 5435.43 | 100.00 |
Total Water End Uses | 5435.43 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 117.00 |
Time Setpoint Not Met During Occupied Cooling | 99.25 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 3861.50 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |COMPONENTS OF PEAK ELECTRICAL DEMAND
| Meter |COMPONENTS OF PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:12
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:37 |
RunPeriod | International Falls Intl Ap MN USA TMY3 WMO#=727470 |
Weather File | International Falls Intl Ap MN USA TMY3 WMO#=727470 |
Latitude [deg] | 48.57 |
Longitude [deg] | -93.4 |
Elevation [m] | 359.00 |
Time Zone | -6.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 3855.02 | 1411.96 | 515.55 | 1411.96 | 515.55 |
Window Opening Area [m2] | 1150.39 | 423.59 | 152.73 | 423.59 | 150.48 |
Window-Wall Ratio [%] | 29.84 | 30.00 | 29.62 | 30.00 | 29.19 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 3752.84 | 1411.96 | 464.46 | 1411.96 | 464.46 |
Window Opening Area [m2] | 1125.85 | 423.59 | 139.34 | 423.59 | 139.34 |
Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 23.8959 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 4.47 | 8.5250 | 0.0000 | |
F2 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F2 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F2 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F2 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F2 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F2 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F2 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F2 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F2 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 8.5250 | 0.0000 | |
F3 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F3 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F3 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F3 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F3 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F3 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F3 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F3 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F3 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 8.5250 | 0.0000 | |
F4 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F4 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F4 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F4 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F4 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F4 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F4 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F4 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F4 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 8.5250 | 0.0000 | |
M SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 17.0500 | 0.0000 | |
F6 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F6 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F6 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F6 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F6 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F6 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F6 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F6 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F6 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 8.5250 | 0.0000 | |
F7 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F7 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F7 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F7 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F7 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F7 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F7 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F7 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F7 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 8.5250 | 0.0000 | |
F8 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F8 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F8 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F8 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F8 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F8 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F8 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F8 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F8 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 8.5250 | 0.0000 | |
F9 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F9 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F9 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F9 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F9 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F9 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F9 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F9 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F9 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 8.5250 | 0.0000 | |
T SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 8.5250 | 263.6661 | |
Total | 7836.48 | 23884.04 | 3855.02 | 1150.39 | 14.0302 | 39.48 | 8.6219 | |||
Conditioned Total | 7059.89 | 21517.16 | 3752.84 | 1125.85 | 14.5420 | 35.57 | 6.6700 | |||
Unconditioned Total | 776.58 | 2366.87 | 102.18 | 24.54 | 9.3775 | 26.3666 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:12
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 04-JAN-20:00 | 04-JAN-08:30 | - | - | - | 29-JUN-17:15 |
Heating | 79904.96 | 265391.88 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 25049.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 10720.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 49704.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 18696.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 1587.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 92291.40 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 186608.34 | 357683.27 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | Boiler | 0.00 | 265391.88 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 20603.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 4445.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 10720.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 49704.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 18696.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 1587.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 92291.40 | 0.00 | 0.00 | 0.00 | 0.00 |
sub cat | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:12
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 1314.48 | 1702.68 | 0.00 | 0.00 | 0.00 |
Cooling | 733.48 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1318.78 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 533.01 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 3582.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 1867.28 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 156.68 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 30.79 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 1491.33 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 9602.61 | 3194.01 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 186.19 | 241.18 | 0.00 | 0.00 | 0.00 |
Cooling | 103.89 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 186.80 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 75.50 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 507.40 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 264.49 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 22.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 4.36 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 211.24 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1360.16 | 452.42 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 186.19 | 241.18 | 0.00 | 0.00 | 0.00 |
Cooling | 103.89 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 186.80 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 75.50 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 507.40 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 264.49 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 22.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 4.36 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 211.24 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1360.16 | 452.42 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:12
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | -32.70 | 0.00 | -32.70 | Wetbulb [C] | 2.40 | 210.00 |
INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 30.10 | 12.40 | 21.10 | Wetbulb [C] | 4.70 | 200.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:12
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 270.00 | 180.00 | |
F2 WWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
F2 SWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F2 NWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F2 WWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
F2 EWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
F2 SWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F2 NWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F2 EWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
F2 NWALL N1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F2 NWALL N2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F2 SWALL S1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F2 SWALL S2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F2 WWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 270.00 | 90.00 | W |
F2 EWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 90.00 | 90.00 | E |
F3 WWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
F3 SWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F3 NWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F3 WWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
F3 EWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
F3 SWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F3 NWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F3 EWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
F3 NWALL N1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F3 NWALL N2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F3 SWALL S1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F3 SWALL S2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F3 WWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 270.00 | 90.00 | W |
F3 EWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 90.00 | 90.00 | E |
F4 WWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
F4 SWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F4 NWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F4 WWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
F4 EWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
F4 SWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F4 NWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F4 EWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
F4 NWALL N1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F4 NWALL N2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F4 SWALL S1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F4 SWALL S2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F4 WWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 270.00 | 90.00 | W |
F4 EWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 90.00 | 90.00 | E |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
M WWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 90.00 | 90.00 | E |
F6 WWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
F6 SWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F6 NWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F6 WWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
F6 EWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
F6 SWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F6 NWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F6 EWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
F6 NWALL N1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F6 NWALL N2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F6 SWALL S1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F6 SWALL S2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F6 WWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 270.00 | 90.00 | W |
F6 EWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 90.00 | 90.00 | E |
F7 WWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
F7 SWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F7 NWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F7 WWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
F7 EWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
F7 SWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F7 NWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F7 EWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
F7 NWALL N1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F7 NWALL N2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F7 SWALL S1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F7 SWALL S2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F7 WWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 270.00 | 90.00 | W |
F7 EWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 90.00 | 90.00 | E |
F8 WWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
F8 SWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F8 NWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F8 WWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
F8 EWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
F8 SWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F8 NWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F8 EWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
F8 NWALL N1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F8 NWALL N2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F8 SWALL S1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F8 SWALL S2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F8 WWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 270.00 | 90.00 | W |
F8 EWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 90.00 | 90.00 | E |
F9 WWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
F9 SWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F9 NWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F9 WWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
F9 EWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
F9 SWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F9 NWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F9 EWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
F9 NWALL N1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F9 NWALL N2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
F9 SWALL S1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F9 SWALL S2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
F9 WWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 270.00 | 90.00 | W |
F9 EWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 90.00 | 90.00 | E |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.238 | 0.247 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.30 | 0.269 | 0.283 | 77.66 | 0.00 | 0.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW3 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW2 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW4 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW6 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW8 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW5 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW7 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW9 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW10 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW11 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW12 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
GWINDOW13 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | G WWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_0.42_SHGC_0.45 | 3.36 | 0.00 | 0.00 | 3.36 | 3.36 | 2.493 | 0.426 | 0.308 | No | G EWALL C | 90.00 | 90.00 | E | ||
F2WINDOW2 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F2 WWALL SWA | 270.00 | 90.00 | W | ||
F2WINDOW3 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F2 SWALL SWA | 180.00 | 90.00 | S | ||
F2WINDOW4 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F2 NWALL NWA | 0.00 | 90.00 | N | ||
F2WINDOW6 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F2 WWALL NWA | 270.00 | 90.00 | W | ||
F2WINDOW8 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F2 EWALL SEA | 90.00 | 90.00 | E | ||
F2WINDOW1 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F2 SWALL SEA | 180.00 | 90.00 | S | ||
F2WINDOW5 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F2 NWALL NEA | 0.00 | 90.00 | N | ||
F2WINDOW7 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F2 EWALL NEA | 90.00 | 90.00 | E | ||
F2WINDOW9 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F2 NWALL N1A | 0.00 | 90.00 | N | ||
F2WINDOW10 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F2 NWALL N2A | 0.00 | 90.00 | N | ||
F2WINDOW11 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F2 SWALL S1A | 180.00 | 90.00 | S | ||
F2WINDOW12 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F2 SWALL S2A | 180.00 | 90.00 | S | ||
F2WINDOW13 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F2 WWALL C | 270.00 | 90.00 | W | ||
F2WINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F2 EWALL C | 90.00 | 90.00 | E | ||
F3WINDOW2 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F3 WWALL SWA | 270.00 | 90.00 | W | ||
F3WINDOW3 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F3 SWALL SWA | 180.00 | 90.00 | S | ||
F3WINDOW4 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F3 NWALL NWA | 0.00 | 90.00 | N | ||
F3WINDOW6 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F3 WWALL NWA | 270.00 | 90.00 | W | ||
F3WINDOW8 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F3 EWALL SEA | 90.00 | 90.00 | E | ||
F3WINDOW1 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F3 SWALL SEA | 180.00 | 90.00 | S | ||
F3WINDOW5 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F3 NWALL NEA | 0.00 | 90.00 | N | ||
F3WINDOW7 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F3 EWALL NEA | 90.00 | 90.00 | E | ||
F3WINDOW9 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F3 NWALL N1A | 0.00 | 90.00 | N | ||
F3WINDOW10 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F3 NWALL N2A | 0.00 | 90.00 | N | ||
F3WINDOW11 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F3 SWALL S1A | 180.00 | 90.00 | S | ||
F3WINDOW12 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F3 SWALL S2A | 180.00 | 90.00 | S | ||
F3WINDOW13 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F3 WWALL C | 270.00 | 90.00 | W | ||
F3WINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F3 EWALL C | 90.00 | 90.00 | E | ||
F4WINDOW2 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F4 WWALL SWA | 270.00 | 90.00 | W | ||
F4WINDOW3 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F4 SWALL SWA | 180.00 | 90.00 | S | ||
F4WINDOW4 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F4 NWALL NWA | 0.00 | 90.00 | N | ||
F4WINDOW6 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F4 WWALL NWA | 270.00 | 90.00 | W | ||
F4WINDOW8 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F4 EWALL SEA | 90.00 | 90.00 | E | ||
F4WINDOW1 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F4 SWALL SEA | 180.00 | 90.00 | S | ||
F4WINDOW5 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F4 NWALL NEA | 0.00 | 90.00 | N | ||
F4WINDOW7 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F4 EWALL NEA | 90.00 | 90.00 | E | ||
F4WINDOW9 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F4 NWALL N1A | 0.00 | 90.00 | N | ||
F4WINDOW10 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F4 NWALL N2A | 0.00 | 90.00 | N | ||
F4WINDOW11 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F4 SWALL S1A | 180.00 | 90.00 | S | ||
F4WINDOW12 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F4 SWALL S2A | 180.00 | 90.00 | S | ||
F4WINDOW13 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F4 WWALL C | 270.00 | 90.00 | W | ||
F4WINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F4 EWALL C | 90.00 | 90.00 | E | ||
MWINDOW2 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW3 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW4 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW6 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW8 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW5 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW7 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW9 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW10 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW11 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW12 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW13 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | M WWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | M EWALL C | 90.00 | 90.00 | E | ||
F6WINDOW2 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F6 WWALL SWA | 270.00 | 90.00 | W | ||
F6WINDOW3 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F6 SWALL SWA | 180.00 | 90.00 | S | ||
F6WINDOW4 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F6 NWALL NWA | 0.00 | 90.00 | N | ||
F6WINDOW6 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F6 WWALL NWA | 270.00 | 90.00 | W | ||
F6WINDOW8 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F6 EWALL SEA | 90.00 | 90.00 | E | ||
F6WINDOW1 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F6 SWALL SEA | 180.00 | 90.00 | S | ||
F6WINDOW5 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F6 NWALL NEA | 0.00 | 90.00 | N | ||
F6WINDOW7 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F6 EWALL NEA | 90.00 | 90.00 | E | ||
F6WINDOW9 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F6 NWALL N1A | 0.00 | 90.00 | N | ||
F6WINDOW10 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F6 NWALL N2A | 0.00 | 90.00 | N | ||
F6WINDOW11 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F6 SWALL S1A | 180.00 | 90.00 | S | ||
F6WINDOW12 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F6 SWALL S2A | 180.00 | 90.00 | S | ||
F6WINDOW13 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F6 WWALL C | 270.00 | 90.00 | W | ||
F6WINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F6 EWALL C | 90.00 | 90.00 | E | ||
F7WINDOW2 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F7 WWALL SWA | 270.00 | 90.00 | W | ||
F7WINDOW3 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F7 SWALL SWA | 180.00 | 90.00 | S | ||
F7WINDOW4 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F7 NWALL NWA | 0.00 | 90.00 | N | ||
F7WINDOW6 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F7 WWALL NWA | 270.00 | 90.00 | W | ||
F7WINDOW8 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F7 EWALL SEA | 90.00 | 90.00 | E | ||
F7WINDOW1 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F7 SWALL SEA | 180.00 | 90.00 | S | ||
F7WINDOW5 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F7 NWALL NEA | 0.00 | 90.00 | N | ||
F7WINDOW7 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F7 EWALL NEA | 90.00 | 90.00 | E | ||
F7WINDOW9 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F7 NWALL N1A | 0.00 | 90.00 | N | ||
F7WINDOW10 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F7 NWALL N2A | 0.00 | 90.00 | N | ||
F7WINDOW11 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F7 SWALL S1A | 180.00 | 90.00 | S | ||
F7WINDOW12 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F7 SWALL S2A | 180.00 | 90.00 | S | ||
F7WINDOW13 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F7 WWALL C | 270.00 | 90.00 | W | ||
F7WINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F7 EWALL C | 90.00 | 90.00 | E | ||
F8WINDOW2 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F8 WWALL SWA | 270.00 | 90.00 | W | ||
F8WINDOW3 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F8 SWALL SWA | 180.00 | 90.00 | S | ||
F8WINDOW4 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F8 NWALL NWA | 0.00 | 90.00 | N | ||
F8WINDOW6 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F8 WWALL NWA | 270.00 | 90.00 | W | ||
F8WINDOW8 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F8 EWALL SEA | 90.00 | 90.00 | E | ||
F8WINDOW1 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F8 SWALL SEA | 180.00 | 90.00 | S | ||
F8WINDOW5 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F8 NWALL NEA | 0.00 | 90.00 | N | ||
F8WINDOW7 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F8 EWALL NEA | 90.00 | 90.00 | E | ||
F8WINDOW9 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F8 NWALL N1A | 0.00 | 90.00 | N | ||
F8WINDOW10 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F8 NWALL N2A | 0.00 | 90.00 | N | ||
F8WINDOW11 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F8 SWALL S1A | 180.00 | 90.00 | S | ||
F8WINDOW12 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F8 SWALL S2A | 180.00 | 90.00 | S | ||
F8WINDOW13 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F8 WWALL C | 270.00 | 90.00 | W | ||
F8WINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F8 EWALL C | 90.00 | 90.00 | E | ||
F9WINDOW2 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F9 WWALL SWA | 270.00 | 90.00 | W | ||
F9WINDOW3 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F9 SWALL SWA | 180.00 | 90.00 | S | ||
F9WINDOW4 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F9 NWALL NWA | 0.00 | 90.00 | N | ||
F9WINDOW6 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F9 WWALL NWA | 270.00 | 90.00 | W | ||
F9WINDOW8 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F9 EWALL SEA | 90.00 | 90.00 | E | ||
F9WINDOW1 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F9 SWALL SEA | 180.00 | 90.00 | S | ||
F9WINDOW5 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F9 NWALL NEA | 0.00 | 90.00 | N | ||
F9WINDOW7 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F9 EWALL NEA | 90.00 | 90.00 | E | ||
F9WINDOW9 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F9 NWALL N1A | 0.00 | 90.00 | N | ||
F9WINDOW10 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F9 NWALL N2A | 0.00 | 90.00 | N | ||
F9WINDOW11 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F9 SWALL S1A | 180.00 | 90.00 | S | ||
F9WINDOW12 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F9 SWALL S2A | 180.00 | 90.00 | S | ||
F9WINDOW13 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F9 WWALL C | 270.00 | 90.00 | W | ||
F9WINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F9 EWALL C | 90.00 | 90.00 | E | ||
TWINDOW2 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW3 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW4 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW6 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW8 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW5 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW7 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW9 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW10 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW11 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW12 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW13 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | T WWALL C | 270.00 | 90.00 | W | ||
TWINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | T EWALL C | 90.00 | 90.00 | E | ||
Total or Average | 1150.39 | 2.493 | 0.426 | 0.308 | ||||||||||||
North Total or Average | 423.59 | 2.493 | 0.426 | 0.308 | ||||||||||||
Non-North Total or Average | 726.80 | 2.493 | 0.426 | 0.308 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:12
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:12
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
G SW APARTMENT_LIGHTS_HARDWIRED | G SW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
G NW APARTMENT_LIGHTS_HARDWIRED | G NW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
OFFICE_LIGHTS_HARDWIRED | OFFICE | 11.9479 | 88.25 | 1054.39 | GeneralLights | LTG_OFF_SCH | 56.26 | 168.00 | 55.46 | 0.0000 | Y | 10.98 |
G NE APARTMENT_LIGHTS_HARDWIRED | G NE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
G N1 APARTMENT_LIGHTS_HARDWIRED | G N1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
G N2 APARTMENT_LIGHTS_HARDWIRED | G N2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
G S1 APARTMENT_LIGHTS_HARDWIRED | G S1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
G S2 APARTMENT_LIGHTS_HARDWIRED | G S2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
G CORRIDOR_LIGHTS_HARDWIRED | G CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
F2 SW APARTMENT_LIGHTS_HARDWIRED | F2 SW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F2 NW APARTMENT_LIGHTS_HARDWIRED | F2 NW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F2 SE APARTMENT_LIGHTS_HARDWIRED | F2 SE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F2 NE APARTMENT_LIGHTS_HARDWIRED | F2 NE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F2 N1 APARTMENT_LIGHTS_HARDWIRED | F2 N1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F2 N2 APARTMENT_LIGHTS_HARDWIRED | F2 N2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F2 S1 APARTMENT_LIGHTS_HARDWIRED | F2 S1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F2 S2 APARTMENT_LIGHTS_HARDWIRED | F2 S2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F2 CORRIDOR_LIGHTS_HARDWIRED | F2 CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
F3 SW APARTMENT_LIGHTS_HARDWIRED | F3 SW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F3 NW APARTMENT_LIGHTS_HARDWIRED | F3 NW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F3 SE APARTMENT_LIGHTS_HARDWIRED | F3 SE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F3 NE APARTMENT_LIGHTS_HARDWIRED | F3 NE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F3 N1 APARTMENT_LIGHTS_HARDWIRED | F3 N1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F3 N2 APARTMENT_LIGHTS_HARDWIRED | F3 N2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F3 S1 APARTMENT_LIGHTS_HARDWIRED | F3 S1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F3 S2 APARTMENT_LIGHTS_HARDWIRED | F3 S2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F3 CORRIDOR_LIGHTS_HARDWIRED | F3 CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
F4 SW APARTMENT_LIGHTS_HARDWIRED | F4 SW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F4 NW APARTMENT_LIGHTS_HARDWIRED | F4 NW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F4 SE APARTMENT_LIGHTS_HARDWIRED | F4 SE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F4 NE APARTMENT_LIGHTS_HARDWIRED | F4 NE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F4 N1 APARTMENT_LIGHTS_HARDWIRED | F4 N1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F4 N2 APARTMENT_LIGHTS_HARDWIRED | F4 N2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F4 S1 APARTMENT_LIGHTS_HARDWIRED | F4 S1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F4 S2 APARTMENT_LIGHTS_HARDWIRED | F4 S2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F4 CORRIDOR_LIGHTS_HARDWIRED | F4 CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
M SW APARTMENT_LIGHTS_HARDWIRED | M SW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
M NW APARTMENT_LIGHTS_HARDWIRED | M NW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
M SE APARTMENT_LIGHTS_HARDWIRED | M SE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
M NE APARTMENT_LIGHTS_HARDWIRED | M NE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
M N1 APARTMENT_LIGHTS_HARDWIRED | M N1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
M N2 APARTMENT_LIGHTS_HARDWIRED | M N2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
M S1 APARTMENT_LIGHTS_HARDWIRED | M S1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
M S2 APARTMENT_LIGHTS_HARDWIRED | M S2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
M CORRIDOR_LIGHTS_HARDWIRED | M CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
F6 SW APARTMENT_LIGHTS_HARDWIRED | F6 SW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F6 NW APARTMENT_LIGHTS_HARDWIRED | F6 NW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F6 SE APARTMENT_LIGHTS_HARDWIRED | F6 SE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F6 NE APARTMENT_LIGHTS_HARDWIRED | F6 NE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F6 N1 APARTMENT_LIGHTS_HARDWIRED | F6 N1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F6 N2 APARTMENT_LIGHTS_HARDWIRED | F6 N2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F6 S1 APARTMENT_LIGHTS_HARDWIRED | F6 S1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F6 S2 APARTMENT_LIGHTS_HARDWIRED | F6 S2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F6 CORRIDOR_LIGHTS_HARDWIRED | F6 CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
F7 SW APARTMENT_LIGHTS_HARDWIRED | F7 SW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F7 NW APARTMENT_LIGHTS_HARDWIRED | F7 NW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F7 SE APARTMENT_LIGHTS_HARDWIRED | F7 SE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F7 NE APARTMENT_LIGHTS_HARDWIRED | F7 NE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F7 N1 APARTMENT_LIGHTS_HARDWIRED | F7 N1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F7 N2 APARTMENT_LIGHTS_HARDWIRED | F7 N2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F7 S1 APARTMENT_LIGHTS_HARDWIRED | F7 S1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F7 S2 APARTMENT_LIGHTS_HARDWIRED | F7 S2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F7 CORRIDOR_LIGHTS_HARDWIRED | F7 CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
F8 SW APARTMENT_LIGHTS_HARDWIRED | F8 SW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F8 NW APARTMENT_LIGHTS_HARDWIRED | F8 NW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F8 SE APARTMENT_LIGHTS_HARDWIRED | F8 SE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F8 NE APARTMENT_LIGHTS_HARDWIRED | F8 NE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F8 N1 APARTMENT_LIGHTS_HARDWIRED | F8 N1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F8 N2 APARTMENT_LIGHTS_HARDWIRED | F8 N2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F8 S1 APARTMENT_LIGHTS_HARDWIRED | F8 S1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F8 S2 APARTMENT_LIGHTS_HARDWIRED | F8 S2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F8 CORRIDOR_LIGHTS_HARDWIRED | F8 CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
F9 SW APARTMENT_LIGHTS_HARDWIRED | F9 SW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F9 NW APARTMENT_LIGHTS_HARDWIRED | F9 NW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F9 SE APARTMENT_LIGHTS_HARDWIRED | F9 SE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F9 NE APARTMENT_LIGHTS_HARDWIRED | F9 NE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F9 N1 APARTMENT_LIGHTS_HARDWIRED | F9 N1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F9 N2 APARTMENT_LIGHTS_HARDWIRED | F9 N2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F9 S1 APARTMENT_LIGHTS_HARDWIRED | F9 S1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F9 S2 APARTMENT_LIGHTS_HARDWIRED | F9 S2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F9 CORRIDOR_LIGHTS_HARDWIRED | F9 CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
T SW APARTMENT_LIGHTS_HARDWIRED | T SW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
T NW APARTMENT_LIGHTS_HARDWIRED | T NW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
T SE APARTMENT_LIGHTS_HARDWIRED | T SE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
T NE APARTMENT_LIGHTS_HARDWIRED | T NE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
T N1 APARTMENT_LIGHTS_HARDWIRED | T N1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
T N2 APARTMENT_LIGHTS_HARDWIRED | T N2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
T S1 APARTMENT_LIGHTS_HARDWIRED | T S1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
T S2 APARTMENT_LIGHTS_HARDWIRED | T S2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
T CORRIDOR_LIGHTS_HARDWIRED | T CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
G SW APARTMENT_LIGHTS_PLUGIN | G SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
G NW APARTMENT_LIGHTS_PLUGIN | G NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
OFFICE_LIGHTS_PLUGIN | OFFICE | 11.9479 | 88.25 | 1054.39 | GeneralLights-plugin | LTG_OFF_SCH | 56.26 | 168.00 | 55.46 | 0.0000 | Y | 10.98 |
G NE APARTMENT_LIGHTS_PLUGIN | G NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
G N1 APARTMENT_LIGHTS_PLUGIN | G N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
G N2 APARTMENT_LIGHTS_PLUGIN | G N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
G S1 APARTMENT_LIGHTS_PLUGIN | G S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
G S2 APARTMENT_LIGHTS_PLUGIN | G S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F2 SW APARTMENT_LIGHTS_PLUGIN | F2 SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F2 NW APARTMENT_LIGHTS_PLUGIN | F2 NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F2 SE APARTMENT_LIGHTS_PLUGIN | F2 SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F2 NE APARTMENT_LIGHTS_PLUGIN | F2 NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F2 N1 APARTMENT_LIGHTS_PLUGIN | F2 N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F2 N2 APARTMENT_LIGHTS_PLUGIN | F2 N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F2 S1 APARTMENT_LIGHTS_PLUGIN | F2 S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F2 S2 APARTMENT_LIGHTS_PLUGIN | F2 S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F3 SW APARTMENT_LIGHTS_PLUGIN | F3 SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F3 NW APARTMENT_LIGHTS_PLUGIN | F3 NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F3 SE APARTMENT_LIGHTS_PLUGIN | F3 SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F3 NE APARTMENT_LIGHTS_PLUGIN | F3 NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F3 N1 APARTMENT_LIGHTS_PLUGIN | F3 N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F3 N2 APARTMENT_LIGHTS_PLUGIN | F3 N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F3 S1 APARTMENT_LIGHTS_PLUGIN | F3 S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F3 S2 APARTMENT_LIGHTS_PLUGIN | F3 S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F4 SW APARTMENT_LIGHTS_PLUGIN | F4 SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F4 NW APARTMENT_LIGHTS_PLUGIN | F4 NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F4 SE APARTMENT_LIGHTS_PLUGIN | F4 SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F4 NE APARTMENT_LIGHTS_PLUGIN | F4 NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F4 N1 APARTMENT_LIGHTS_PLUGIN | F4 N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F4 N2 APARTMENT_LIGHTS_PLUGIN | F4 N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F4 S1 APARTMENT_LIGHTS_PLUGIN | F4 S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F4 S2 APARTMENT_LIGHTS_PLUGIN | F4 S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
M SW APARTMENT_LIGHTS_PLUGIN | M SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
M NW APARTMENT_LIGHTS_PLUGIN | M NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
M SE APARTMENT_LIGHTS_PLUGIN | M SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
M NE APARTMENT_LIGHTS_PLUGIN | M NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
M N1 APARTMENT_LIGHTS_PLUGIN | M N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
M N2 APARTMENT_LIGHTS_PLUGIN | M N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
M S1 APARTMENT_LIGHTS_PLUGIN | M S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
M S2 APARTMENT_LIGHTS_PLUGIN | M S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
M CORRIDOR_LIGHTS_PLUGIN | M CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights-plugin | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
F6 SW APARTMENT_LIGHTS_PLUGIN | F6 SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F6 NW APARTMENT_LIGHTS_PLUGIN | F6 NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F6 SE APARTMENT_LIGHTS_PLUGIN | F6 SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F6 NE APARTMENT_LIGHTS_PLUGIN | F6 NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F6 N1 APARTMENT_LIGHTS_PLUGIN | F6 N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F6 N2 APARTMENT_LIGHTS_PLUGIN | F6 N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F6 S1 APARTMENT_LIGHTS_PLUGIN | F6 S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F6 S2 APARTMENT_LIGHTS_PLUGIN | F6 S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F7 SW APARTMENT_LIGHTS_PLUGIN | F7 SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F7 NW APARTMENT_LIGHTS_PLUGIN | F7 NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F7 SE APARTMENT_LIGHTS_PLUGIN | F7 SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F7 NE APARTMENT_LIGHTS_PLUGIN | F7 NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F7 N1 APARTMENT_LIGHTS_PLUGIN | F7 N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F7 N2 APARTMENT_LIGHTS_PLUGIN | F7 N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F7 S1 APARTMENT_LIGHTS_PLUGIN | F7 S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F7 S2 APARTMENT_LIGHTS_PLUGIN | F7 S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F8 SW APARTMENT_LIGHTS_PLUGIN | F8 SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F8 NW APARTMENT_LIGHTS_PLUGIN | F8 NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F8 SE APARTMENT_LIGHTS_PLUGIN | F8 SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F8 NE APARTMENT_LIGHTS_PLUGIN | F8 NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F8 N1 APARTMENT_LIGHTS_PLUGIN | F8 N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F8 N2 APARTMENT_LIGHTS_PLUGIN | F8 N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F8 S1 APARTMENT_LIGHTS_PLUGIN | F8 S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F8 S2 APARTMENT_LIGHTS_PLUGIN | F8 S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F9 SW APARTMENT_LIGHTS_PLUGIN | F9 SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F9 NW APARTMENT_LIGHTS_PLUGIN | F9 NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F9 SE APARTMENT_LIGHTS_PLUGIN | F9 SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F9 NE APARTMENT_LIGHTS_PLUGIN | F9 NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F9 N1 APARTMENT_LIGHTS_PLUGIN | F9 N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F9 N2 APARTMENT_LIGHTS_PLUGIN | F9 N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F9 S1 APARTMENT_LIGHTS_PLUGIN | F9 S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F9 S2 APARTMENT_LIGHTS_PLUGIN | F9 S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
T SW APARTMENT_LIGHTS_PLUGIN | T SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
T NW APARTMENT_LIGHTS_PLUGIN | T NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
T SE APARTMENT_LIGHTS_PLUGIN | T SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
T NE APARTMENT_LIGHTS_PLUGIN | T NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
T N1 APARTMENT_LIGHTS_PLUGIN | T N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
T N2 APARTMENT_LIGHTS_PLUGIN | T N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
T S1 APARTMENT_LIGHTS_PLUGIN | T S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
T S2 APARTMENT_LIGHTS_PLUGIN | T S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
Interior Lighting Total | 7.3426 | 14974.03 | 109947.72 | 416.41 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 10720.10 | AstronomicalClock | - | 83.64 | 83.64 | 168.30 | |
Exterior Lighting Total | 10720.10 | 168.30 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:12
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
CENTRAL BOILER | Boiler:HotWater | 279500.98 | 0.80 | ||
CENTRAL TOWER | EvaporativeFluidCooler:SingleSpeed | 223600.78 |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
HEAT PUMP COOLING MODE AIRLOOP G SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3451.84 | 2314.73 | 1137.12 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3086.52 | 2053.24 | 1033.28 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP OFFICE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4870.99 | 3279.95 | 1591.03 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2744.85 | 1770.62 | 974.24 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2010.15 | 1254.09 | 756.06 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2019.21 | 1257.04 | 762.17 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2474.30 | 1604.26 | 870.04 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2548.46 | 1659.05 | 889.41 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4445.64 | 3035.49 | 1410.15 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3987.51 | 2698.18 | 1289.33 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4402.78 | 2993.30 | 1409.48 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3082.89 | 2043.66 | 1039.23 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2303.16 | 1486.91 | 816.25 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2281.65 | 1471.32 | 810.33 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3214.86 | 2138.50 | 1076.36 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3240.92 | 2158.68 | 1082.24 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4493.56 | 3058.23 | 1435.33 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4055.97 | 2736.45 | 1319.52 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4236.71 | 2857.76 | 1378.95 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3163.11 | 2091.53 | 1071.59 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2380.30 | 1537.02 | 843.28 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2358.96 | 1521.56 | 837.40 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3283.11 | 2182.62 | 1100.49 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3299.11 | 2194.48 | 1104.63 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4520.85 | 3068.94 | 1451.91 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4087.71 | 2750.73 | 1336.98 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4246.99 | 2856.14 | 1390.85 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3192.47 | 2104.79 | 1087.68 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2409.90 | 1554.06 | 855.84 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2388.59 | 1538.65 | 849.94 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3309.40 | 2196.63 | 1112.77 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3323.39 | 2207.00 | 1116.39 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4573.47 | 3100.13 | 1473.34 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4144.18 | 2784.95 | 1359.23 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4301.34 | 2888.79 | 1412.55 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3246.30 | 2137.57 | 1108.73 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2462.66 | 1588.71 | 873.95 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2441.40 | 1573.34 | 868.06 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3359.48 | 2229.19 | 1130.29 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3373.17 | 2239.33 | 1133.84 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4533.54 | 3064.16 | 1469.38 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4104.94 | 2749.77 | 1355.17 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4265.07 | 2855.71 | 1409.36 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3206.11 | 2102.50 | 1103.61 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2423.03 | 1556.95 | 866.08 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2401.87 | 1541.69 | 860.18 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3317.79 | 2194.71 | 1123.09 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3331.48 | 2204.83 | 1126.65 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4531.05 | 3055.84 | 1475.21 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4098.41 | 2739.52 | 1358.90 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4260.11 | 2846.54 | 1413.57 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3198.15 | 2091.82 | 1106.34 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2415.10 | 1548.59 | 866.51 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2402.16 | 1537.87 | 864.29 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3311.28 | 2185.87 | 1125.41 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3321.33 | 2194.09 | 1127.24 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4539.70 | 3057.14 | 1482.56 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4108.78 | 2742.28 | 1366.50 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4270.44 | 2849.25 | 1421.20 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3206.06 | 2093.28 | 1112.78 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2432.82 | 1557.60 | 875.22 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2412.22 | 1542.78 | 869.44 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3317.33 | 2187.43 | 1129.90 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3327.27 | 2195.55 | 1131.72 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4659.80 | 3141.73 | 1518.07 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4229.99 | 2826.85 | 1403.14 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4361.91 | 2911.17 | 1450.75 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3256.14 | 2123.84 | 1132.30 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2529.98 | 1627.02 | 902.96 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2516.89 | 1616.16 | 900.73 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3389.19 | 2237.53 | 1151.66 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3403.08 | 2247.80 | 1155.28 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5618.26 | 3836.26 | 1782.00 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4926.66 | 3333.21 | 1593.45 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5196.96 | 3523.87 | 1673.09 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3852.17 | 2552.53 | 1299.64 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3020.72 | 1966.56 | 1054.15 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3023.29 | 1967.06 | 1056.22 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4373.50 | 2962.81 | 1410.69 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4387.09 | 2972.92 | 1414.17 | 0.68 | 0.00 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
None |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
HEAT PUMP HEATING MODE AIRLOOP G SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 3451.84 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 3086.52 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP OFFICE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4870.99 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 2744.85 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2010.15 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2019.21 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2474.30 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2548.46 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4445.64 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 3987.51 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4402.78 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3082.89 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2303.16 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2281.65 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3214.86 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3240.92 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4493.56 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4055.97 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4236.71 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3163.11 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2380.30 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2358.96 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3283.11 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3299.11 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4520.85 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4087.71 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4246.99 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3192.47 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2409.90 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2388.59 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3309.40 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3323.39 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4573.47 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4144.18 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4301.34 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3246.30 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2462.66 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2441.40 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3359.48 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3373.17 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4533.54 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4104.94 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4265.07 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3206.11 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2423.03 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2401.87 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3317.79 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3331.48 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4531.05 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4098.41 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4260.11 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3198.15 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2415.10 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2402.16 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3311.28 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3321.33 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4539.70 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4108.78 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4270.44 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3206.06 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2432.82 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2412.22 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3317.33 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3327.27 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4659.80 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4229.99 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4361.91 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3256.14 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2529.98 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2516.89 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3389.19 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3403.08 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5618.26 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4926.66 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5196.96 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3852.17 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3020.72 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3023.29 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4373.50 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4387.09 | 0.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW | Coil:Heating:Electric | 4944.67 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW | Coil:Heating:Electric | 4965.09 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE | Coil:Heating:Electric | 6214.19 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE | Coil:Heating:Electric | 4971.91 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 | Coil:Heating:Electric | 3939.61 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 | Coil:Heating:Electric | 3939.76 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 | Coil:Heating:Electric | 3916.93 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 | Coil:Heating:Electric | 3925.64 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW | Coil:Heating:Electric | 4606.99 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW | Coil:Heating:Electric | 4616.20 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE | Coil:Heating:Electric | 4637.98 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE | Coil:Heating:Electric | 4622.75 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 | Coil:Heating:Electric | 3382.29 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 | Coil:Heating:Electric | 3382.44 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 | Coil:Heating:Electric | 3376.40 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 | Coil:Heating:Electric | 3378.03 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW | Coil:Heating:Electric | 4574.00 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW | Coil:Heating:Electric | 4583.34 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE | Coil:Heating:Electric | 4581.52 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE | Coil:Heating:Electric | 4588.38 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 | Coil:Heating:Electric | 3304.67 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 | Coil:Heating:Electric | 3304.78 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 | Coil:Heating:Electric | 3296.71 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 | Coil:Heating:Electric | 3297.03 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW | Coil:Heating:Electric | 4633.69 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW | Coil:Heating:Electric | 4641.73 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE | Coil:Heating:Electric | 4637.60 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE | Coil:Heating:Electric | 4645.39 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 | Coil:Heating:Electric | 3325.06 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 | Coil:Heating:Electric | 3325.14 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 | Coil:Heating:Electric | 3318.11 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 | Coil:Heating:Electric | 3318.22 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW | Coil:Heating:Electric | 4672.87 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW | Coil:Heating:Electric | 4678.04 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE | Coil:Heating:Electric | 4675.30 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE | Coil:Heating:Electric | 4680.45 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 | Coil:Heating:Electric | 3331.45 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 | Coil:Heating:Electric | 3331.50 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 | Coil:Heating:Electric | 3327.35 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 | Coil:Heating:Electric | 3327.41 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW | Coil:Heating:Electric | 4778.63 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW | Coil:Heating:Electric | 4783.03 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE | Coil:Heating:Electric | 4779.91 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE | Coil:Heating:Electric | 4784.30 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 | Coil:Heating:Electric | 3409.09 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 | Coil:Heating:Electric | 3409.12 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 | Coil:Heating:Electric | 3405.73 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 | Coil:Heating:Electric | 3405.76 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW | Coil:Heating:Electric | 4853.25 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW | Coil:Heating:Electric | 4855.79 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE | Coil:Heating:Electric | 4853.49 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE | Coil:Heating:Electric | 4856.03 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 | Coil:Heating:Electric | 3458.97 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 | Coil:Heating:Electric | 3458.98 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 | Coil:Heating:Electric | 3457.51 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 | Coil:Heating:Electric | 3457.52 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW | Coil:Heating:Electric | 4937.27 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW | Coil:Heating:Electric | 4937.70 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE | Coil:Heating:Electric | 4936.56 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE | Coil:Heating:Electric | 4936.99 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 | Coil:Heating:Electric | 3520.85 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 | Coil:Heating:Electric | 3520.83 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 | Coil:Heating:Electric | 3521.49 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 | Coil:Heating:Electric | 3521.48 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW | Coil:Heating:Electric | 5217.07 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW | Coil:Heating:Electric | 5212.12 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE | Coil:Heating:Electric | 5215.46 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE | Coil:Heating:Electric | 5210.51 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 | Coil:Heating:Electric | 3765.56 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 | Coil:Heating:Electric | 3765.53 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 | Coil:Heating:Electric | 3771.14 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 | Coil:Heating:Electric | 3771.10 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW | Coil:Heating:Electric | 6357.66 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW | Coil:Heating:Electric | 6361.29 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE | Coil:Heating:Electric | 6355.44 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE | Coil:Heating:Electric | 6359.08 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 | Coil:Heating:Electric | 4970.24 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 | Coil:Heating:Electric | 4970.19 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 | Coil:Heating:Electric | 4964.21 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 | Coil:Heating:Electric | 4964.16 | 1.00 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
AIRLOOP G SW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.21 | 234.57 | 1120.11 | 1.00 | General |
AIRLOOP G NW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.19 | 208.82 | 1120.11 | 1.00 | General |
AIRLOOP OFFICE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.30 | 332.13 | 1120.11 | 1.00 | General |
AIRLOOP G NE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.16 | 176.03 | 1120.11 | 1.00 | General |
AIRLOOP G N1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.11 | 121.54 | 1120.11 | 1.00 | General |
AIRLOOP G N2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.11 | 121.55 | 1120.11 | 1.00 | General |
AIRLOOP G S1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.14 | 156.43 | 1120.11 | 1.00 | General |
AIRLOOP G S2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.15 | 162.46 | 1120.11 | 1.00 | General |
AIRLOOP F2 SW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.28 | 314.59 | 1120.11 | 1.00 | General |
AIRLOOP F2 NW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.25 | 278.43 | 1120.11 | 1.00 | General |
AIRLOOP F2 SE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.27 | 306.88 | 1120.11 | 1.00 | General |
AIRLOOP F2 NE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.19 | 208.15 | 1120.11 | 1.00 | General |
AIRLOOP F2 N1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.13 | 148.91 | 1120.11 | 1.00 | General |
AIRLOOP F2 N2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.13 | 147.21 | 1120.11 | 1.00 | General |
AIRLOOP F2 S1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.19 | 214.18 | 1120.11 | 1.00 | General |
AIRLOOP F2 S2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.19 | 216.61 | 1120.11 | 1.00 | General |
AIRLOOP F3 SW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.28 | 316.30 | 1120.11 | 1.00 | General |
AIRLOOP F3 NW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.25 | 281.86 | 1120.11 | 1.00 | General |
AIRLOOP F3 SE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 291.20 | 1120.11 | 1.00 | General |
AIRLOOP F3 NE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.19 | 212.66 | 1120.11 | 1.00 | General |
AIRLOOP F3 N1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.14 | 153.98 | 1120.11 | 1.00 | General |
AIRLOOP F3 N2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.14 | 152.28 | 1120.11 | 1.00 | General |
AIRLOOP F3 S1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 218.77 | 1120.11 | 1.00 | General |
AIRLOOP F3 S2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 220.07 | 1120.11 | 1.00 | General |
AIRLOOP F4 SW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.28 | 316.88 | 1120.11 | 1.00 | General |
AIRLOOP F4 NW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.25 | 282.84 | 1120.11 | 1.00 | General |
AIRLOOP F4 SE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 290.43 | 1120.11 | 1.00 | General |
AIRLOOP F4 NE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.19 | 213.56 | 1120.11 | 1.00 | General |
AIRLOOP F4 N1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.14 | 155.52 | 1120.11 | 1.00 | General |
AIRLOOP F4 N2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.14 | 153.83 | 1120.11 | 1.00 | General |
AIRLOOP F4 S1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 219.95 | 1120.11 | 1.00 | General |
AIRLOOP F4 S2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 221.09 | 1120.11 | 1.00 | General |
AIRLOOP M SW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.29 | 319.83 | 1120.11 | 1.00 | General |
AIRLOOP M NW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 286.12 | 1120.11 | 1.00 | General |
AIRLOOP M SE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 293.54 | 1120.11 | 1.00 | General |
AIRLOOP M NE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.19 | 216.70 | 1120.11 | 1.00 | General |
AIRLOOP M N1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.14 | 159.05 | 1120.11 | 1.00 | General |
AIRLOOP M N2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.14 | 157.37 | 1120.11 | 1.00 | General |
AIRLOOP M S1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 223.24 | 1120.11 | 1.00 | General |
AIRLOOP M S2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 224.36 | 1120.11 | 1.00 | General |
AIRLOOP F6 SW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.28 | 315.47 | 1120.11 | 1.00 | General |
AIRLOOP F6 NW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.25 | 281.85 | 1120.11 | 1.00 | General |
AIRLOOP F6 SE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 289.50 | 1120.11 | 1.00 | General |
AIRLOOP F6 NE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.19 | 212.46 | 1120.11 | 1.00 | General |
AIRLOOP F6 N1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.14 | 155.34 | 1120.11 | 1.00 | General |
AIRLOOP F6 N2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.14 | 153.67 | 1120.11 | 1.00 | General |
AIRLOOP F6 S1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 219.21 | 1120.11 | 1.00 | General |
AIRLOOP F6 S2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 220.32 | 1120.11 | 1.00 | General |
AIRLOOP F7 SW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.28 | 313.82 | 1120.11 | 1.00 | General |
AIRLOOP F7 NW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.25 | 280.37 | 1120.11 | 1.00 | General |
AIRLOOP F7 SE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 288.14 | 1120.11 | 1.00 | General |
AIRLOOP F7 NE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.19 | 210.95 | 1120.11 | 1.00 | General |
AIRLOOP F7 N1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.14 | 154.22 | 1120.11 | 1.00 | General |
AIRLOOP F7 N2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.14 | 152.59 | 1120.11 | 1.00 | General |
AIRLOOP F7 S1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.19 | 217.82 | 1120.11 | 1.00 | General |
AIRLOOP F7 S2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 218.93 | 1120.11 | 1.00 | General |
AIRLOOP F8 SW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.28 | 313.63 | 1120.11 | 1.00 | General |
AIRLOOP F8 NW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.25 | 280.35 | 1120.11 | 1.00 | General |
AIRLOOP F8 SE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 288.12 | 1120.11 | 1.00 | General |
AIRLOOP F8 NE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.19 | 210.80 | 1120.11 | 1.00 | General |
AIRLOOP F8 N1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.14 | 154.56 | 1120.11 | 1.00 | General |
AIRLOOP F8 N2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.14 | 152.94 | 1120.11 | 1.00 | General |
AIRLOOP F8 S1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.19 | 217.80 | 1120.11 | 1.00 | General |
AIRLOOP F8 S2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 218.89 | 1120.11 | 1.00 | General |
AIRLOOP F9 SW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.29 | 322.99 | 1120.11 | 1.00 | General |
AIRLOOP F9 NW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 289.34 | 1120.11 | 1.00 | General |
AIRLOOP F9 SE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 294.41 | 1120.11 | 1.00 | General |
AIRLOOP F9 NE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.19 | 213.25 | 1120.11 | 1.00 | General |
AIRLOOP F9 N1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.15 | 162.47 | 1120.11 | 1.00 | General |
AIRLOOP F9 N2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.14 | 160.81 | 1120.11 | 1.00 | General |
AIRLOOP F9 S1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 223.11 | 1120.11 | 1.00 | General |
AIRLOOP F9 S2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 224.24 | 1120.11 | 1.00 | General |
AIRLOOP T SW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.35 | 396.04 | 1120.11 | 1.00 | General |
AIRLOOP T NW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 343.36 | 1120.11 | 1.00 | General |
AIRLOOP T SE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.32 | 361.61 | 1120.11 | 1.00 | General |
AIRLOOP T NE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.23 | 259.31 | 1120.11 | 1.00 | General |
AIRLOOP T N1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.17 | 193.53 | 1120.11 | 1.00 | General |
AIRLOOP T N2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.17 | 193.32 | 1120.11 | 1.00 | General |
AIRLOOP T S1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.27 | 302.83 | 1120.11 | 1.00 | General |
AIRLOOP T S2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.27 | 303.94 | 1120.11 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
SHWSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.0003 | 36.93 | 127739.32 | 0.30 |
PLANT CIRC PUMP | Pump:ConstantSpeed | Intermittent | 179045.11 | 0.0061 | 1550.54 | 255050.01 | 0.90 |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SHWSYS1 WATER HEATER | WaterHeater:Mixed | 2.27 | 175842.64 | 0.80 | 0.00 | 0.00 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:12
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 2135.46 | 2562.55 | 0.175 | 0.209 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:15:00 | 29.11 | 0.01270 |
G NW APARTMENT | 1901.03 | 2281.24 | 0.155 | 0.186 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 26.66 | 0.01270 |
OFFICE | 3023.64 | 3628.37 | 0.247 | 0.297 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 29.79 | 0.01270 |
G NE APARTMENT | 1331.99 | 1598.39 | 0.109 | 0.131 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 25.85 | 0.01270 |
G N1 APARTMENT | 934.70 | 1121.64 | 0.076 | 0.092 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:15:00 | 24.92 | 0.01270 |
G N2 APARTMENT | 916.46 | 1099.75 | 0.075 | 0.090 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:15:00 | 24.92 | 0.01270 |
G S1 APARTMENT | 1424.09 | 1708.91 | 0.116 | 0.140 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.95 | 0.01270 |
G S2 APARTMENT | 1479.03 | 1774.83 | 0.121 | 0.145 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.95 | 0.01270 |
F2 SW APARTMENT | 2863.89 | 3436.67 | 0.234 | 0.281 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 27.43 | 0.01270 |
F2 NW APARTMENT | 2534.72 | 3041.67 | 0.207 | 0.249 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 26.66 | 0.01270 |
F2 SE APARTMENT | 2793.68 | 3352.42 | 0.228 | 0.274 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 29.79 | 0.01270 |
F2 NE APARTMENT | 1894.89 | 2273.86 | 0.155 | 0.186 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 25.85 | 0.01270 |
F2 N1 APARTMENT | 1355.64 | 1626.77 | 0.111 | 0.133 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:15:00 | 24.92 | 0.01270 |
F2 N2 APARTMENT | 1340.09 | 1608.11 | 0.110 | 0.131 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:15:00 | 24.92 | 0.01270 |
F2 S1 APARTMENT | 1949.86 | 2339.84 | 0.159 | 0.191 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 30.10 | 0.01270 |
F2 S2 APARTMENT | 1971.92 | 2366.31 | 0.161 | 0.193 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.95 | 0.01270 |
F3 SW APARTMENT | 2879.43 | 3455.32 | 0.235 | 0.282 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 27.43 | 0.01270 |
F3 NW APARTMENT | 2565.88 | 3079.05 | 0.210 | 0.252 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 26.66 | 0.01270 |
F3 SE APARTMENT | 2650.89 | 3181.07 | 0.217 | 0.260 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 29.79 | 0.01270 |
F3 NE APARTMENT | 1935.95 | 2323.14 | 0.158 | 0.190 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 25.85 | 0.01270 |
F3 N1 APARTMENT | 1401.72 | 1682.07 | 0.115 | 0.137 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:15:00 | 24.92 | 0.01270 |
F3 N2 APARTMENT | 1386.31 | 1663.57 | 0.113 | 0.136 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:15:00 | 24.92 | 0.01270 |
F3 S1 APARTMENT | 1991.58 | 2389.90 | 0.163 | 0.195 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.95 | 0.01270 |
F3 S2 APARTMENT | 2003.46 | 2404.16 | 0.164 | 0.196 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.95 | 0.01270 |
F4 SW APARTMENT | 2884.73 | 3461.68 | 0.236 | 0.283 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 27.43 | 0.01270 |
F4 NW APARTMENT | 2574.80 | 3089.76 | 0.210 | 0.253 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 26.66 | 0.01270 |
F4 SE APARTMENT | 2643.90 | 3172.69 | 0.216 | 0.259 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 29.79 | 0.01270 |
F4 NE APARTMENT | 1944.07 | 2332.89 | 0.159 | 0.191 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 25.85 | 0.01270 |
F4 N1 APARTMENT | 1415.74 | 1698.89 | 0.116 | 0.139 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:15:00 | 24.92 | 0.01270 |
F4 N2 APARTMENT | 1400.38 | 1680.45 | 0.114 | 0.137 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:15:00 | 24.92 | 0.01270 |
F4 S1 APARTMENT | 2002.37 | 2402.84 | 0.164 | 0.196 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.95 | 0.01270 |
F4 S2 APARTMENT | 2012.76 | 2415.31 | 0.164 | 0.197 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.95 | 0.01270 |
M SW APARTMENT | 2911.51 | 3493.81 | 0.238 | 0.286 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 27.43 | 0.01270 |
M NW APARTMENT | 2604.66 | 3125.59 | 0.213 | 0.255 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 26.66 | 0.01270 |
M SE APARTMENT | 2672.19 | 3206.63 | 0.218 | 0.262 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 29.79 | 0.01270 |
M NE APARTMENT | 1972.68 | 2367.21 | 0.161 | 0.193 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 25.85 | 0.01270 |
M N1 APARTMENT | 1447.89 | 1737.47 | 0.118 | 0.142 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:15:00 | 24.92 | 0.01270 |
M N2 APARTMENT | 1432.58 | 1719.09 | 0.117 | 0.140 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:15:00 | 24.92 | 0.01270 |
M S1 APARTMENT | 2032.29 | 2438.75 | 0.166 | 0.199 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.95 | 0.01270 |
M S2 APARTMENT | 2042.46 | 2450.95 | 0.167 | 0.200 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.95 | 0.01270 |
F6 SW APARTMENT | 2871.78 | 3446.14 | 0.235 | 0.282 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 27.43 | 0.01270 |
F6 NW APARTMENT | 2565.76 | 3078.91 | 0.210 | 0.252 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 26.66 | 0.01270 |
F6 SE APARTMENT | 2635.40 | 3162.48 | 0.215 | 0.258 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 29.79 | 0.01270 |
F6 NE APARTMENT | 1934.04 | 2320.85 | 0.158 | 0.190 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 25.85 | 0.01270 |
F6 N1 APARTMENT | 1414.11 | 1696.93 | 0.116 | 0.139 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:15:00 | 24.92 | 0.01270 |
F6 N2 APARTMENT | 1398.91 | 1678.70 | 0.114 | 0.137 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:15:00 | 24.92 | 0.01270 |
F6 S1 APARTMENT | 1995.55 | 2394.66 | 0.163 | 0.196 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.95 | 0.01270 |
F6 S2 APARTMENT | 2005.70 | 2406.84 | 0.164 | 0.197 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.95 | 0.01270 |
F7 SW APARTMENT | 2856.74 | 3428.09 | 0.233 | 0.280 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 27.74 | 0.01270 |
F7 NW APARTMENT | 2552.25 | 3062.70 | 0.209 | 0.250 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 26.66 | 0.01270 |
F7 SE APARTMENT | 2622.98 | 3147.57 | 0.214 | 0.257 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 29.79 | 0.01270 |
F7 NE APARTMENT | 1920.25 | 2304.30 | 0.157 | 0.188 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 25.85 | 0.01270 |
F7 N1 APARTMENT | 1403.95 | 1684.74 | 0.115 | 0.138 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:15:00 | 24.92 | 0.01270 |
F7 N2 APARTMENT | 1389.04 | 1666.84 | 0.114 | 0.136 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26 | 0.01270 |
F7 S1 APARTMENT | 1982.94 | 2379.53 | 0.162 | 0.194 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 30.10 | 0.01270 |
F7 S2 APARTMENT | 1992.98 | 2391.58 | 0.163 | 0.195 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.95 | 0.01270 |
F8 SW APARTMENT | 2855.07 | 3426.09 | 0.233 | 0.280 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 27.74 | 0.01270 |
F8 NW APARTMENT | 2552.10 | 3062.52 | 0.209 | 0.250 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 26.66 | 0.01270 |
F8 SE APARTMENT | 2622.75 | 3147.30 | 0.214 | 0.257 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 29.79 | 0.01270 |
F8 NE APARTMENT | 1918.93 | 2302.72 | 0.157 | 0.188 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 25.85 | 0.01270 |
F8 N1 APARTMENT | 1407.03 | 1688.44 | 0.115 | 0.138 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26 | 0.01270 |
F8 N2 APARTMENT | 1392.29 | 1670.75 | 0.114 | 0.137 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26 | 0.01270 |
F8 S1 APARTMENT | 1982.73 | 2379.28 | 0.162 | 0.194 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 30.10 | 0.01270 |
F8 S2 APARTMENT | 1992.67 | 2391.20 | 0.163 | 0.195 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.95 | 0.01270 |
F9 SW APARTMENT | 2940.26 | 3528.32 | 0.240 | 0.288 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 27.43 | 0.01270 |
F9 NW APARTMENT | 2633.89 | 3160.67 | 0.215 | 0.258 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 26.66 | 0.01270 |
F9 SE APARTMENT | 2679.99 | 3215.99 | 0.219 | 0.263 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.95 | 0.01270 |
F9 NE APARTMENT | 1941.20 | 2329.44 | 0.159 | 0.190 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 26.32 | 0.01270 |
F9 N1 APARTMENT | 1479.01 | 1774.81 | 0.121 | 0.145 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:15:00 | 24.92 | 0.01270 |
F9 N2 APARTMENT | 1463.94 | 1756.73 | 0.120 | 0.144 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 25.26 | 0.01270 |
F9 S1 APARTMENT | 2031.11 | 2437.33 | 0.166 | 0.199 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 30.10 | 0.01270 |
F9 S2 APARTMENT | 2041.39 | 2449.67 | 0.167 | 0.200 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 30.10 | 0.01270 |
T SW APARTMENT | 3605.09 | 4326.11 | 0.295 | 0.354 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 | 29.73 | 0.01270 |
T NW APARTMENT | 3125.58 | 3750.70 | 0.255 | 0.307 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 27.74 | 0.01270 |
T SE APARTMENT | 3291.73 | 3950.08 | 0.269 | 0.323 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 29.79 | 0.01270 |
T NE APARTMENT | 2360.43 | 2832.52 | 0.193 | 0.232 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 26.78 | 0.01270 |
T N1 APARTMENT | 1761.76 | 2114.11 | 0.144 | 0.173 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:15:00 | 29.91 | 0.01270 |
T N2 APARTMENT | 1759.85 | 2111.82 | 0.144 | 0.173 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 30.10 | 0.01270 |
T S1 APARTMENT | 2756.73 | 3308.08 | 0.225 | 0.270 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.95 | 0.01270 |
T S2 APARTMENT | 2766.89 | 3320.27 | 0.226 | 0.271 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.95 | 0.01270 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 2797.12 | 3356.54 | 0.130 | 0.156 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -32.70 | 0.00018 |
G NW APARTMENT | 2814.38 | 3377.26 | 0.131 | 0.157 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -32.70 | 0.00018 |
OFFICE | 3222.53 | 3867.04 | 0.150 | 0.180 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 18:45:00 | -32.70 | 0.00018 |
G NE APARTMENT | 2820.15 | 3384.18 | 0.131 | 0.157 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -32.70 | 0.00018 |
G N1 APARTMENT | 1947.18 | 2336.61 | 0.090 | 0.109 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -32.70 | 0.00018 |
G N2 APARTMENT | 1947.30 | 2336.76 | 0.090 | 0.109 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -32.70 | 0.00018 |
G S1 APARTMENT | 1928.00 | 2313.59 | 0.090 | 0.107 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -32.70 | 0.00018 |
G S2 APARTMENT | 1935.36 | 2322.43 | 0.090 | 0.108 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -32.70 | 0.00018 |
F2 SW APARTMENT | 2511.58 | 3013.90 | 0.117 | 0.140 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F2 NW APARTMENT | 2519.37 | 3023.24 | 0.117 | 0.140 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F2 SE APARTMENT | 2537.79 | 3045.34 | 0.118 | 0.141 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F2 NE APARTMENT | 2524.90 | 3029.88 | 0.117 | 0.141 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F2 N1 APARTMENT | 1475.90 | 1771.08 | 0.069 | 0.082 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F2 N2 APARTMENT | 1476.02 | 1771.22 | 0.069 | 0.082 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F2 S1 APARTMENT | 1470.91 | 1765.10 | 0.068 | 0.082 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F2 S2 APARTMENT | 1472.30 | 1766.76 | 0.068 | 0.082 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F3 SW APARTMENT | 2483.69 | 2980.43 | 0.115 | 0.138 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F3 NW APARTMENT | 2491.58 | 2989.90 | 0.116 | 0.139 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F3 SE APARTMENT | 2490.05 | 2988.06 | 0.116 | 0.139 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F3 NE APARTMENT | 2495.85 | 2995.02 | 0.116 | 0.139 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F3 N1 APARTMENT | 1410.26 | 1692.31 | 0.065 | 0.079 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F3 N2 APARTMENT | 1410.36 | 1692.43 | 0.065 | 0.079 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F3 S1 APARTMENT | 1403.52 | 1684.23 | 0.065 | 0.078 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F3 S2 APARTMENT | 1403.80 | 1684.56 | 0.065 | 0.078 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F4 SW APARTMENT | 2534.17 | 3041.01 | 0.118 | 0.141 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F4 NW APARTMENT | 2540.97 | 3049.16 | 0.118 | 0.142 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F4 SE APARTMENT | 2537.47 | 3044.97 | 0.118 | 0.141 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F4 NE APARTMENT | 2544.07 | 3052.88 | 0.118 | 0.142 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F4 N1 APARTMENT | 1427.50 | 1713.01 | 0.066 | 0.080 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F4 N2 APARTMENT | 1427.57 | 1713.09 | 0.066 | 0.080 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F4 S1 APARTMENT | 1421.63 | 1705.95 | 0.066 | 0.079 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F4 S2 APARTMENT | 1421.72 | 1706.06 | 0.066 | 0.079 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
M SW APARTMENT | 2567.30 | 3080.77 | 0.119 | 0.143 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
M NW APARTMENT | 2571.68 | 3086.02 | 0.119 | 0.143 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
M SE APARTMENT | 2569.36 | 3083.23 | 0.119 | 0.143 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
M NE APARTMENT | 2573.72 | 3088.46 | 0.120 | 0.143 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
M N1 APARTMENT | 1432.91 | 1719.49 | 0.067 | 0.080 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
M N2 APARTMENT | 1432.96 | 1719.55 | 0.067 | 0.080 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
M S1 APARTMENT | 1429.45 | 1715.34 | 0.066 | 0.080 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
M S2 APARTMENT | 1429.49 | 1715.39 | 0.066 | 0.080 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F6 SW APARTMENT | 2656.75 | 3188.09 | 0.123 | 0.148 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F6 NW APARTMENT | 2660.46 | 3192.56 | 0.124 | 0.148 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F6 SE APARTMENT | 2657.83 | 3189.39 | 0.123 | 0.148 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F6 NE APARTMENT | 2661.54 | 3193.85 | 0.124 | 0.148 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F6 N1 APARTMENT | 1498.57 | 1798.28 | 0.070 | 0.084 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F6 N2 APARTMENT | 1498.59 | 1798.31 | 0.070 | 0.084 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F6 S1 APARTMENT | 1495.73 | 1794.88 | 0.069 | 0.083 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F6 S2 APARTMENT | 1495.76 | 1794.91 | 0.069 | 0.083 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F7 SW APARTMENT | 2719.85 | 3263.83 | 0.126 | 0.152 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F7 NW APARTMENT | 2722.00 | 3266.40 | 0.126 | 0.152 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F7 SE APARTMENT | 2720.06 | 3264.07 | 0.126 | 0.152 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F7 NE APARTMENT | 2722.20 | 3266.64 | 0.126 | 0.152 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F7 N1 APARTMENT | 1540.76 | 1848.91 | 0.072 | 0.086 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F7 N2 APARTMENT | 1540.76 | 1848.92 | 0.072 | 0.086 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F7 S1 APARTMENT | 1539.52 | 1847.43 | 0.071 | 0.086 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F7 S2 APARTMENT | 1539.53 | 1847.43 | 0.071 | 0.086 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F8 SW APARTMENT | 2790.91 | 3349.09 | 0.130 | 0.156 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F8 NW APARTMENT | 2791.27 | 3349.53 | 0.130 | 0.156 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F8 SE APARTMENT | 2790.30 | 3348.37 | 0.130 | 0.155 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F8 NE APARTMENT | 2790.67 | 3348.80 | 0.130 | 0.155 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F8 N1 APARTMENT | 1593.08 | 1911.70 | 0.074 | 0.089 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F8 N2 APARTMENT | 1593.07 | 1911.68 | 0.074 | 0.089 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F8 S1 APARTMENT | 1593.63 | 1912.35 | 0.074 | 0.089 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F8 S2 APARTMENT | 1593.62 | 1912.34 | 0.074 | 0.089 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F9 SW APARTMENT | 3027.52 | 3633.02 | 0.141 | 0.169 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F9 NW APARTMENT | 3023.33 | 3628.00 | 0.140 | 0.168 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F9 SE APARTMENT | 3026.16 | 3631.39 | 0.141 | 0.169 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F9 NE APARTMENT | 3021.98 | 3626.37 | 0.140 | 0.168 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F9 N1 APARTMENT | 1800.03 | 2160.03 | 0.084 | 0.100 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F9 N2 APARTMENT | 1800.00 | 2160.00 | 0.084 | 0.100 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F9 S1 APARTMENT | 1804.74 | 2165.69 | 0.084 | 0.101 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
F9 S2 APARTMENT | 1804.71 | 2165.65 | 0.084 | 0.101 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
T SW APARTMENT | 3992.06 | 4790.48 | 0.185 | 0.222 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
T NW APARTMENT | 3995.14 | 4794.17 | 0.186 | 0.223 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
T SE APARTMENT | 3990.19 | 4788.23 | 0.185 | 0.222 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
T NE APARTMENT | 3993.27 | 4791.92 | 0.185 | 0.223 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
T N1 APARTMENT | 2818.77 | 3382.52 | 0.131 | 0.157 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
T N2 APARTMENT | 2818.73 | 3382.47 | 0.131 | 0.157 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
T S1 APARTMENT | 2813.66 | 3376.40 | 0.131 | 0.157 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
T S2 APARTMENT | 2813.62 | 3376.35 | 0.131 | 0.157 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -32.70 | 0.00018 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
AIRLOOP G SW | 0.21 | 0.21 | 0.16 | 0.16 |
AIRLOOP G NW | 0.19 | 0.19 | 0.16 | 0.16 |
AIRLOOP OFFICE | 0.30 | 0.30 | 0.18 | 0.18 |
AIRLOOP G NE | 0.13 | 0.13 | 0.16 | 0.16 |
AIRLOOP G N1 | 0.09 | 0.09 | 0.11 | 0.11 |
AIRLOOP G N2 | 0.09 | 0.09 | 0.11 | 0.11 |
AIRLOOP G S1 | 0.14 | 0.14 | 0.11 | 0.11 |
AIRLOOP G S2 | 0.15 | 0.15 | 0.11 | 0.11 |
AIRLOOP F2 SW | 0.28 | 0.28 | 0.14 | 0.14 |
AIRLOOP F2 NW | 0.25 | 0.25 | 0.14 | 0.14 |
AIRLOOP F2 SE | 0.27 | 0.27 | 0.14 | 0.14 |
AIRLOOP F2 NE | 0.19 | 0.19 | 0.14 | 0.14 |
AIRLOOP F2 N1 | 0.13 | 0.13 | 0.08 | 0.08 |
AIRLOOP F2 N2 | 0.13 | 0.13 | 0.08 | 0.08 |
AIRLOOP F2 S1 | 0.19 | 0.19 | 0.08 | 0.08 |
AIRLOOP F2 S2 | 0.19 | 0.19 | 0.08 | 0.08 |
AIRLOOP F3 SW | 0.28 | 0.28 | 0.14 | 0.14 |
AIRLOOP F3 NW | 0.25 | 0.25 | 0.14 | 0.14 |
AIRLOOP F3 SE | 0.26 | 0.26 | 0.14 | 0.14 |
AIRLOOP F3 NE | 0.19 | 0.19 | 0.14 | 0.14 |
AIRLOOP F3 N1 | 0.14 | 0.14 | 0.08 | 0.08 |
AIRLOOP F3 N2 | 0.14 | 0.14 | 0.08 | 0.08 |
AIRLOOP F3 S1 | 0.20 | 0.20 | 0.08 | 0.08 |
AIRLOOP F3 S2 | 0.20 | 0.20 | 0.08 | 0.08 |
AIRLOOP F4 SW | 0.28 | 0.28 | 0.14 | 0.14 |
AIRLOOP F4 NW | 0.25 | 0.25 | 0.14 | 0.14 |
AIRLOOP F4 SE | 0.26 | 0.26 | 0.14 | 0.14 |
AIRLOOP F4 NE | 0.19 | 0.19 | 0.14 | 0.14 |
AIRLOOP F4 N1 | 0.14 | 0.14 | 0.08 | 0.08 |
AIRLOOP F4 N2 | 0.14 | 0.14 | 0.08 | 0.08 |
AIRLOOP F4 S1 | 0.20 | 0.20 | 0.08 | 0.08 |
AIRLOOP F4 S2 | 0.20 | 0.20 | 0.08 | 0.08 |
AIRLOOP M SW | 0.29 | 0.29 | 0.14 | 0.14 |
AIRLOOP M NW | 0.26 | 0.26 | 0.14 | 0.14 |
AIRLOOP M SE | 0.26 | 0.26 | 0.14 | 0.14 |
AIRLOOP M NE | 0.19 | 0.19 | 0.14 | 0.14 |
AIRLOOP M N1 | 0.14 | 0.14 | 0.08 | 0.08 |
AIRLOOP M N2 | 0.14 | 0.14 | 0.08 | 0.08 |
AIRLOOP M S1 | 0.20 | 0.20 | 0.08 | 0.08 |
AIRLOOP M S2 | 0.20 | 0.20 | 0.08 | 0.08 |
AIRLOOP F6 SW | 0.28 | 0.28 | 0.15 | 0.15 |
AIRLOOP F6 NW | 0.25 | 0.25 | 0.15 | 0.15 |
AIRLOOP F6 SE | 0.26 | 0.26 | 0.15 | 0.15 |
AIRLOOP F6 NE | 0.19 | 0.19 | 0.15 | 0.15 |
AIRLOOP F6 N1 | 0.14 | 0.14 | 0.08 | 0.08 |
AIRLOOP F6 N2 | 0.14 | 0.14 | 0.08 | 0.08 |
AIRLOOP F6 S1 | 0.20 | 0.20 | 0.08 | 0.08 |
AIRLOOP F6 S2 | 0.20 | 0.20 | 0.08 | 0.08 |
AIRLOOP F7 SW | 0.28 | 0.28 | 0.15 | 0.15 |
AIRLOOP F7 NW | 0.25 | 0.25 | 0.15 | 0.15 |
AIRLOOP F7 SE | 0.26 | 0.26 | 0.15 | 0.15 |
AIRLOOP F7 NE | 0.19 | 0.19 | 0.15 | 0.15 |
AIRLOOP F7 N1 | 0.14 | 0.14 | 0.09 | 0.09 |
AIRLOOP F7 N2 | 0.14 | 0.14 | 0.09 | 0.09 |
AIRLOOP F7 S1 | 0.19 | 0.19 | 0.09 | 0.09 |
AIRLOOP F7 S2 | 0.20 | 0.20 | 0.09 | 0.09 |
AIRLOOP F8 SW | 0.28 | 0.28 | 0.16 | 0.16 |
AIRLOOP F8 NW | 0.25 | 0.25 | 0.16 | 0.16 |
AIRLOOP F8 SE | 0.26 | 0.26 | 0.16 | 0.16 |
AIRLOOP F8 NE | 0.19 | 0.19 | 0.16 | 0.16 |
AIRLOOP F8 N1 | 0.14 | 0.14 | 0.09 | 0.09 |
AIRLOOP F8 N2 | 0.14 | 0.14 | 0.09 | 0.09 |
AIRLOOP F8 S1 | 0.19 | 0.19 | 0.09 | 0.09 |
AIRLOOP F8 S2 | 0.20 | 0.20 | 0.09 | 0.09 |
AIRLOOP F9 SW | 0.29 | 0.29 | 0.17 | 0.17 |
AIRLOOP F9 NW | 0.26 | 0.26 | 0.17 | 0.17 |
AIRLOOP F9 SE | 0.26 | 0.26 | 0.17 | 0.17 |
AIRLOOP F9 NE | 0.19 | 0.19 | 0.17 | 0.17 |
AIRLOOP F9 N1 | 0.15 | 0.15 | 0.10 | 0.10 |
AIRLOOP F9 N2 | 0.14 | 0.14 | 0.10 | 0.10 |
AIRLOOP F9 S1 | 0.20 | 0.20 | 0.10 | 0.10 |
AIRLOOP F9 S2 | 0.20 | 0.20 | 0.10 | 0.10 |
AIRLOOP T SW | 0.35 | 0.35 | 0.22 | 0.22 |
AIRLOOP T NW | 0.31 | 0.31 | 0.22 | 0.22 |
AIRLOOP T SE | 0.32 | 0.32 | 0.22 | 0.22 |
AIRLOOP T NE | 0.23 | 0.23 | 0.22 | 0.22 |
AIRLOOP T N1 | 0.17 | 0.17 | 0.16 | 0.16 |
AIRLOOP T N2 | 0.17 | 0.17 | 0.16 | 0.16 |
AIRLOOP T S1 | 0.27 | 0.27 | 0.16 | 0.16 |
AIRLOOP T S2 | 0.27 | 0.27 | 0.16 | 0.16 |
Report: System Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:12
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 3804.00 | 6635.50 | 2315.25 |
G NW APARTMENT | 4073.50 | 7128.00 | 2981.50 |
OFFICE | 1036.25 | 1309.50 | 306.25 |
G NE APARTMENT | 4114.50 | 7171.50 | 3020.75 |
G N1 APARTMENT | 3259.75 | 7491.00 | 2529.75 |
G N2 APARTMENT | 3253.50 | 7485.75 | 2524.75 |
G S1 APARTMENT | 2971.00 | 6832.25 | 1676.50 |
G S2 APARTMENT | 2982.50 | 6783.75 | 1648.25 |
F2 SW APARTMENT | 3749.25 | 5509.25 | 1339.00 |
F2 NW APARTMENT | 3993.25 | 6214.25 | 2083.50 |
F2 SE APARTMENT | 3804.50 | 5402.50 | 1252.25 |
F2 NE APARTMENT | 4000.75 | 6297.25 | 2094.25 |
F2 N1 APARTMENT | 2911.50 | 6434.75 | 1251.00 |
F2 N2 APARTMENT | 2908.50 | 6445.50 | 1254.50 |
F2 S1 APARTMENT | 3027.75 | 5525.75 | 714.25 |
F2 S2 APARTMENT | 3034.50 | 5504.25 | 710.25 |
F3 SW APARTMENT | 3749.75 | 5331.75 | 1220.00 |
F3 NW APARTMENT | 3995.25 | 6073.75 | 1968.00 |
F3 SE APARTMENT | 3789.00 | 5333.00 | 1204.00 |
F3 NE APARTMENT | 4005.00 | 6163.50 | 1971.50 |
F3 N1 APARTMENT | 2922.00 | 6251.75 | 1084.00 |
F3 N2 APARTMENT | 2920.00 | 6262.75 | 1087.25 |
F3 S1 APARTMENT | 3099.25 | 5252.75 | 610.00 |
F3 S2 APARTMENT | 3105.50 | 5249.00 | 610.50 |
F4 SW APARTMENT | 3771.00 | 5314.00 | 1224.00 |
F4 NW APARTMENT | 4021.75 | 6051.75 | 1976.00 |
F4 SE APARTMENT | 3810.25 | 5338.25 | 1222.25 |
F4 NE APARTMENT | 4034.25 | 6130.50 | 1981.75 |
F4 N1 APARTMENT | 2950.25 | 6187.25 | 1066.50 |
F4 N2 APARTMENT | 2948.50 | 6199.75 | 1069.25 |
F4 S1 APARTMENT | 3124.75 | 5199.25 | 597.75 |
F4 S2 APARTMENT | 3129.00 | 5198.75 | 598.50 |
M SW APARTMENT | 3763.25 | 5307.50 | 1210.25 |
M NW APARTMENT | 4010.00 | 6038.50 | 1948.50 |
M SE APARTMENT | 3802.50 | 5338.75 | 1208.75 |
M NE APARTMENT | 4017.50 | 6119.00 | 1954.25 |
M N1 APARTMENT | 2943.75 | 6153.00 | 1028.25 |
M N2 APARTMENT | 2941.00 | 6166.50 | 1030.00 |
M S1 APARTMENT | 3132.00 | 5168.75 | 580.75 |
M S2 APARTMENT | 3131.75 | 5171.75 | 581.75 |
F6 SW APARTMENT | 3759.00 | 5423.75 | 1308.75 |
F6 NW APARTMENT | 4007.25 | 6159.25 | 2062.75 |
F6 SE APARTMENT | 3797.75 | 5460.50 | 1309.25 |
F6 NE APARTMENT | 4030.50 | 6260.25 | 2079.50 |
F6 N1 APARTMENT | 2921.75 | 6288.75 | 1141.25 |
F6 N2 APARTMENT | 2918.25 | 6298.75 | 1144.25 |
F6 S1 APARTMENT | 3069.00 | 5287.50 | 630.50 |
F6 S2 APARTMENT | 3071.75 | 5288.75 | 631.75 |
F7 SW APARTMENT | 3747.25 | 5521.25 | 1375.75 |
F7 NW APARTMENT | 4008.00 | 6251.75 | 2126.75 |
F7 SE APARTMENT | 3788.50 | 5559.50 | 1375.75 |
F7 NE APARTMENT | 4039.50 | 6337.75 | 2153.25 |
F7 N1 APARTMENT | 2920.25 | 6381.50 | 1205.00 |
F7 N2 APARTMENT | 2916.75 | 6388.75 | 1207.00 |
F7 S1 APARTMENT | 3034.00 | 5392.75 | 666.25 |
F7 S2 APARTMENT | 3035.00 | 5395.25 | 667.50 |
F8 SW APARTMENT | 3756.25 | 5615.50 | 1452.00 |
F8 NW APARTMENT | 4032.50 | 6322.00 | 2198.00 |
F8 SE APARTMENT | 3789.25 | 5641.75 | 1452.00 |
F8 NE APARTMENT | 4058.75 | 6410.50 | 2230.00 |
F8 N1 APARTMENT | 2932.50 | 6450.25 | 1278.00 |
F8 N2 APARTMENT | 2927.50 | 6462.75 | 1278.25 |
F8 S1 APARTMENT | 3001.25 | 5496.00 | 708.50 |
F8 S2 APARTMENT | 3002.75 | 5500.50 | 709.25 |
F9 SW APARTMENT | 3883.25 | 5757.00 | 1689.25 |
F9 NW APARTMENT | 4177.00 | 6403.50 | 2405.50 |
F9 SE APARTMENT | 3922.25 | 5762.25 | 1687.00 |
F9 NE APARTMENT | 4209.25 | 6503.75 | 2441.50 |
F9 N1 APARTMENT | 3148.75 | 6550.00 | 1554.75 |
F9 N2 APARTMENT | 3138.75 | 6554.00 | 1552.00 |
F9 S1 APARTMENT | 3064.25 | 5670.00 | 878.25 |
F9 S2 APARTMENT | 3062.25 | 5666.25 | 880.25 |
T SW APARTMENT | 4756.75 | 6134.75 | 2844.75 |
T NW APARTMENT | 4930.25 | 6695.00 | 3416.50 |
T SE APARTMENT | 4788.50 | 6143.25 | 2843.50 |
T NE APARTMENT | 4956.50 | 6821.25 | 3464.25 |
T N1 APARTMENT | 4255.00 | 6880.25 | 2881.50 |
T N2 APARTMENT | 4256.75 | 6880.50 | 2887.00 |
T S1 APARTMENT | 4105.75 | 6074.00 | 2210.25 |
T S2 APARTMENT | 4112.75 | 6070.75 | 2212.50 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 6277.50 | 7651.75 | 3861.50 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 3.00 | 9.00 | 3.00 | 9.00 |
G NW APARTMENT | 3.25 | 6.50 | 3.25 | 6.50 |
OFFICE | 0.75 | 0.00 | 0.00 | 0.00 |
G NE APARTMENT | 3.25 | 0.50 | 3.25 | 0.50 |
G N1 APARTMENT | 1.25 | 2.50 | 1.25 | 2.50 |
G N2 APARTMENT | 1.25 | 2.25 | 1.25 | 2.25 |
G S1 APARTMENT | 1.00 | 7.00 | 1.00 | 7.00 |
G S2 APARTMENT | 1.25 | 3.75 | 1.25 | 3.75 |
F2 SW APARTMENT | 3.00 | 6.75 | 3.00 | 6.75 |
F2 NW APARTMENT | 0.75 | 6.75 | 0.75 | 6.75 |
F2 SE APARTMENT | 3.00 | 0.00 | 3.00 | 0.00 |
F2 NE APARTMENT | 0.75 | 26.25 | 0.75 | 26.25 |
F2 N1 APARTMENT | 1.50 | 27.75 | 1.50 | 27.75 |
F2 N2 APARTMENT | 1.25 | 31.50 | 1.25 | 31.50 |
F2 S1 APARTMENT | 1.50 | 5.00 | 1.50 | 5.00 |
F2 S2 APARTMENT | 0.25 | 4.25 | 0.25 | 4.25 |
F3 SW APARTMENT | 2.25 | 7.25 | 2.25 | 7.25 |
F3 NW APARTMENT | 2.25 | 7.25 | 2.25 | 7.25 |
F3 SE APARTMENT | 2.25 | 2.00 | 2.25 | 2.00 |
F3 NE APARTMENT | 1.75 | 32.75 | 1.75 | 32.75 |
F3 N1 APARTMENT | 1.75 | 44.75 | 1.75 | 44.75 |
F3 N2 APARTMENT | 1.25 | 51.25 | 1.25 | 51.25 |
F3 S1 APARTMENT | 1.50 | 7.25 | 1.50 | 7.25 |
F3 S2 APARTMENT | 2.25 | 6.50 | 2.25 | 6.50 |
F4 SW APARTMENT | 1.75 | 7.50 | 1.75 | 7.50 |
F4 NW APARTMENT | 1.00 | 7.50 | 1.00 | 7.50 |
F4 SE APARTMENT | 2.00 | 3.25 | 2.00 | 3.25 |
F4 NE APARTMENT | 2.25 | 34.25 | 2.25 | 34.25 |
F4 N1 APARTMENT | 2.25 | 50.50 | 2.25 | 50.50 |
F4 N2 APARTMENT | 1.75 | 54.25 | 1.75 | 54.25 |
F4 S1 APARTMENT | 1.50 | 9.00 | 1.50 | 9.00 |
F4 S2 APARTMENT | 1.00 | 7.75 | 1.00 | 7.75 |
M SW APARTMENT | 2.00 | 8.25 | 2.00 | 8.25 |
M NW APARTMENT | 1.75 | 7.75 | 1.75 | 7.75 |
M SE APARTMENT | 2.50 | 4.00 | 2.50 | 4.00 |
M NE APARTMENT | 2.50 | 36.50 | 2.50 | 36.50 |
M N1 APARTMENT | 1.50 | 52.75 | 1.50 | 52.75 |
M N2 APARTMENT | 0.75 | 56.00 | 0.75 | 56.00 |
M S1 APARTMENT | 0.50 | 9.50 | 0.50 | 9.50 |
M S2 APARTMENT | 0.75 | 8.75 | 0.75 | 8.75 |
F6 SW APARTMENT | 2.75 | 8.50 | 2.75 | 8.50 |
F6 NW APARTMENT | 1.00 | 7.75 | 1.00 | 7.75 |
F6 SE APARTMENT | 2.50 | 5.50 | 2.50 | 5.50 |
F6 NE APARTMENT | 2.00 | 38.50 | 2.00 | 38.50 |
F6 N1 APARTMENT | 3.75 | 52.75 | 3.75 | 52.75 |
F6 N2 APARTMENT | 2.75 | 57.50 | 2.75 | 57.50 |
F6 S1 APARTMENT | 2.00 | 10.00 | 2.00 | 10.00 |
F6 S2 APARTMENT | 1.75 | 10.00 | 1.75 | 10.00 |
F7 SW APARTMENT | 1.25 | 8.00 | 1.25 | 8.00 |
F7 NW APARTMENT | 1.75 | 7.75 | 1.75 | 7.75 |
F7 SE APARTMENT | 3.00 | 7.50 | 3.00 | 7.50 |
F7 NE APARTMENT | 2.00 | 40.50 | 2.00 | 40.50 |
F7 N1 APARTMENT | 2.75 | 53.00 | 2.75 | 53.00 |
F7 N2 APARTMENT | 3.75 | 57.00 | 3.75 | 57.00 |
F7 S1 APARTMENT | 2.25 | 10.25 | 2.25 | 10.25 |
F7 S2 APARTMENT | 2.00 | 10.00 | 2.00 | 10.00 |
F8 SW APARTMENT | 0.50 | 8.00 | 0.50 | 8.00 |
F8 NW APARTMENT | 1.75 | 8.00 | 1.75 | 8.00 |
F8 SE APARTMENT | 2.00 | 9.00 | 2.00 | 9.00 |
F8 NE APARTMENT | 1.00 | 41.00 | 1.00 | 41.00 |
F8 N1 APARTMENT | 1.50 | 53.00 | 1.50 | 53.00 |
F8 N2 APARTMENT | 1.75 | 56.75 | 1.75 | 56.75 |
F8 S1 APARTMENT | 2.25 | 10.75 | 2.25 | 10.75 |
F8 S2 APARTMENT | 2.50 | 10.75 | 2.50 | 10.75 |
F9 SW APARTMENT | 1.25 | 8.00 | 1.25 | 8.00 |
F9 NW APARTMENT | 1.50 | 7.75 | 1.50 | 7.75 |
F9 SE APARTMENT | 1.00 | 7.75 | 1.00 | 7.75 |
F9 NE APARTMENT | 1.75 | 46.50 | 1.75 | 46.50 |
F9 N1 APARTMENT | 1.50 | 48.00 | 1.50 | 48.00 |
F9 N2 APARTMENT | 2.75 | 52.00 | 2.75 | 52.00 |
F9 S1 APARTMENT | 1.25 | 10.25 | 1.25 | 10.25 |
F9 S2 APARTMENT | 1.00 | 9.50 | 1.00 | 9.50 |
T SW APARTMENT | 0.25 | 6.75 | 0.25 | 6.75 |
T NW APARTMENT | 0.00 | 8.00 | 0.00 | 8.00 |
T SE APARTMENT | 0.25 | 9.25 | 0.25 | 9.25 |
T NE APARTMENT | 0.75 | 44.25 | 0.75 | 44.25 |
T N1 APARTMENT | 3.75 | 53.50 | 3.75 | 53.50 |
T N2 APARTMENT | 5.25 | 53.50 | 5.25 | 53.50 |
T S1 APARTMENT | 1.75 | 4.25 | 1.75 | 4.25 |
T S2 APARTMENT | 1.75 | 3.50 | 1.75 | 3.50 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 117.75 | 99.25 | 117.00 | 99.25 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:12
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.098 | 0.000 | 0.260 |
G NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.098 | 0.000 | 0.249 |
OFFICE | 0.94 | 1.00 | 268.96 | 0.518 | 0.115 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.098 | 0.000 | 0.250 |
G N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.059 | 0.000 | 0.244 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.059 | 0.000 | 0.244 |
G S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.059 | 0.000 | 0.257 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.059 | 0.000 | 0.258 |
F2 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.141 | 0.000 | 0.299 |
F2 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.141 | 0.000 | 0.287 |
F2 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.141 | 0.000 | 0.300 |
F2 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.141 | 0.000 | 0.287 |
F2 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.085 | 0.000 | 0.283 |
F2 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.085 | 0.000 | 0.283 |
F2 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.085 | 0.000 | 0.298 |
F2 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.085 | 0.000 | 0.298 |
F3 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.167 | 0.000 | 0.326 |
F3 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.167 | 0.000 | 0.312 |
F3 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.167 | 0.000 | 0.327 |
F3 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.167 | 0.000 | 0.312 |
F3 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.101 | 0.000 | 0.308 |
F3 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.101 | 0.000 | 0.308 |
F3 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.101 | 0.000 | 0.325 |
F3 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.101 | 0.000 | 0.325 |
F4 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.187 | 0.000 | 0.338 |
F4 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.187 | 0.000 | 0.322 |
F4 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.187 | 0.000 | 0.339 |
F4 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.187 | 0.000 | 0.322 |
F4 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.113 | 0.000 | 0.319 |
F4 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.113 | 0.000 | 0.319 |
F4 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.113 | 0.000 | 0.337 |
F4 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.113 | 0.000 | 0.337 |
M SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.203 | 0.000 | 0.354 |
M NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.203 | 0.000 | 0.336 |
M SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.203 | 0.000 | 0.354 |
M NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.203 | 0.000 | 0.336 |
M N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.122 | 0.000 | 0.334 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.122 | 0.000 | 0.334 |
M S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.123 | 0.000 | 0.353 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.123 | 0.000 | 0.353 |
F6 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.217 | 0.000 | 0.367 |
F6 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.217 | 0.000 | 0.348 |
F6 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.217 | 0.000 | 0.367 |
F6 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.217 | 0.000 | 0.348 |
F6 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.131 | 0.000 | 0.345 |
F6 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.131 | 0.000 | 0.345 |
F6 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.131 | 0.000 | 0.366 |
F6 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.131 | 0.000 | 0.366 |
F7 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.229 | 0.000 | 0.379 |
F7 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.229 | 0.000 | 0.359 |
F7 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.229 | 0.000 | 0.379 |
F7 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.229 | 0.000 | 0.359 |
F7 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.138 | 0.000 | 0.356 |
F7 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.138 | 0.000 | 0.356 |
F7 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.138 | 0.000 | 0.378 |
F7 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.138 | 0.000 | 0.378 |
F8 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.241 | 0.000 | 0.390 |
F8 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.240 | 0.000 | 0.369 |
F8 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.241 | 0.000 | 0.390 |
F8 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.240 | 0.000 | 0.369 |
F8 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.145 | 0.000 | 0.366 |
F8 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.145 | 0.000 | 0.366 |
F8 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.145 | 0.000 | 0.389 |
F8 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.145 | 0.000 | 0.389 |
F9 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.251 | 0.000 | 0.400 |
F9 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.250 | 0.000 | 0.378 |
F9 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.251 | 0.000 | 0.400 |
F9 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.250 | 0.000 | 0.378 |
F9 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.151 | 0.000 | 0.375 |
F9 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.151 | 0.000 | 0.375 |
F9 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.151 | 0.000 | 0.399 |
F9 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.151 | 0.000 | 0.399 |
T SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.260 | 0.000 | 0.407 |
T NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.260 | 0.000 | 0.385 |
T SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.260 | 0.000 | 0.408 |
T NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.260 | 0.000 | 0.385 |
T N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.157 | 0.000 | 0.382 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.157 | 0.000 | 0.382 |
T S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.157 | 0.000 | 0.406 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.157 | 0.000 | 0.406 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.96 | 0.500 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:12
Surfaces by ClassTotal | Outdoors | |
Wall | 420 | 140 |
Floor | 90 | 9 |
Roof | 90 | 9 |
Internal Mass | 80 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 140 | 140 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 80 |
Conditioned Zones | 80 |
Unconditioned Zones | 10 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 4197 |
Defaulted Fields | 814 |
Fields with Defaults | 11307 |
Autosized Fields | 1293 |
Autosizable Fields | 1630 |
Autocalculated Fields | 907 |
Autocalculatable Fields | 1710 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2018-10-19 09:40:12
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 3032.08 | 56637.27 | 22-MAY-02:45 | 186608.34 | 04-JAN-21:00 |
Electricity:Building | 1547.51 | 26803.46 | 01-JAN-03:15 | 79071.91 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity | 416.41 | 7980.64 | 01-JAN-00:15 | 25049.15 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 348.50 | 6974.01 | 01-JAN-00:15 | 20603.34 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 29.50 | 508.27 | 01-JAN-00:15 | 2167.24 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 21.95 | 379.58 | 01-JAN-00:15 | 1622.33 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
Electricity:Zone:F2 SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F2 NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F2 SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F2 NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F2 N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F2 N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F2 S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F2 S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F2 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F2 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
Electricity:Zone:F3 SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F3 NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F3 SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F3 NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F3 N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F3 N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F3 S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F3 S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F3 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F3 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
Electricity:Zone:F4 SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F4 NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F4 SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F4 NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F4 N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F4 N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F4 S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F4 S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F4 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F4 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
Electricity:Zone:M SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M CORRIDOR | 37.06 | 1175.12 | 01-JAN-00:15 | 1175.12 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 37.06 | 1175.12 | 01-JAN-00:15 | 1175.12 | 01-JAN-00:15 |
Electricity:Zone:F6 SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F6 NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F6 SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F6 NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F6 N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F6 N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F6 S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F6 S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F6 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F6 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
Electricity:Zone:F7 SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F7 NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F7 SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F7 NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F7 N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F7 N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F7 S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F7 S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F7 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F7 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
Electricity:Zone:F8 SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F8 NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F8 SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F8 NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F8 N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F8 N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F8 S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F8 S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F8 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F8 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
Electricity:Zone:F9 SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F9 NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F9 SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F9 NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F9 N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F9 N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F9 S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F9 S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F9 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F9 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
Electricity:Zone:T SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T CORRIDOR | 177.27 | 1611.36 | 01-JAN-00:15 | 10825.51 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 67.92 | 1006.63 | 01-JAN-00:15 | 4445.81 | 01-JAN-19:15 |
InteriorEquipment:Electricity | 1131.09 | 18822.82 | 01-JAN-03:15 | 56933.81 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 1131.09 | 18822.82 | 01-JAN-03:15 | 56933.81 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 7.55 | 128.69 | 01-JAN-00:15 | 544.91 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T CORRIDOR | 158.74 | 1023.79 | 01-JAN-00:15 | 10237.95 | 01-JAN-07:15 |
Fans:Electricity | 589.61 | 18696.25 | 01-JAN-02:30 | 18696.25 | 01-JAN-00:15 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Electricity:HVAC | 1257.08 | 19076.78 | 22-MAY-02:45 | 123962.01 | 04-JAN-06:00 |
ElectricityProduced:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityProduced:HVAC | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricityProduced | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 3032.08 | 56637.27 | 22-MAY-02:45 | 186608.34 | 04-JAN-21:00 |
ElectricityPurchased:Plant | 3032.08 | 56637.27 | 22-MAY-02:45 | 186608.34 | 04-JAN-21:00 |
Cogeneration:ElectricityPurchased | 3032.08 | 56637.27 | 22-MAY-02:45 | 186608.34 | 04-JAN-21:00 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 3032.08 | 56637.27 | 22-MAY-02:45 | 186608.34 | 04-JAN-21:00 |
ElectricityNet:Plant | 3032.08 | 56637.27 | 22-MAY-02:45 | 186608.34 | 04-JAN-21:00 |
Cogeneration:ElectricityNet | 3032.08 | 56637.27 | 22-MAY-02:45 | 186608.34 | 04-JAN-21:00 |
ExteriorLights:Electricity | 168.30 | 0.00 | 01-JAN-08:15 | 10720.10 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 168.30 | 0.00 | 01-JAN-08:15 | 10720.10 | 01-JAN-00:15 |
General:Fans:Electricity | 589.61 | 18696.25 | 01-JAN-02:30 | 18696.25 | 01-JAN-00:15 |
Cooling:Electricity | 231.60 | 0.00 | 01-JAN-00:15 | 72143.48 | 30-JUN-15:15 |
Heating:Electricity | 415.05 | 0.00 | 10-APR-15:45 | 104852.45 | 04-JAN-06:00 |
Electricity:Plant | 59.19 | 36.93 | 03-MAY-19:30 | 4522.23 | 29-JUN-16:00 |
HeatRejection:Electricity | 9.72 | 0.00 | 01-JAN-00:15 | 2934.76 | 29-JUN-16:00 |
Boiler Parasitic:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Pumps:Electricity | 49.47 | 36.93 | 03-MAY-19:30 | 1587.47 | 01-JAN-00:15 |
WIRED_LTG_ELECTRICITY | 0.62 | 0.00 | 01-JAN-00:15 | 37.57 | 01-JAN-19:30 |
WIRED_INT_EQUIP | 973.17 | 1018.50 | 01-JAN-00:15 | 10185.00 | 01-JAN-07:15 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 2946.50 | 9260.51 | 19-MAR-23:00 | 357683.27 | 04-JAN-08:30 |
Gas:Plant | 2946.50 | 9260.51 | 19-MAR-23:00 | 357683.27 | 04-JAN-08:30 |
WaterSystems:Gas | 1375.77 | 9260.51 | 01-JAN-00:15 | 96441.49 | 26-FEB-08:00 |
Water Heater:WaterSystems:Gas | 1375.77 | 9260.51 | 01-JAN-00:15 | 96441.49 | 26-FEB-08:00 |
Heating:Gas | 1570.73 | 0.00 | 28-FEB-15:15 | 275735.10 | 04-JAN-06:00 |
Boiler:Heating:Gas | 1570.73 | 0.00 | 28-FEB-15:15 | 275735.10 | 04-JAN-06:00 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
PlantLoopCoolingDemand:Facility | 957.76 | 0.00 | 01-JAN-00:15 | 339067.32 | 03-JUL-14:15 |
PlantLoopCoolingDemand:HVAC | 957.76 | 0.00 | 01-JAN-00:15 | 339067.32 | 03-JUL-14:15 |
CoolingCoils:PlantLoopCoolingDemand | 957.76 | 0.00 | 01-JAN-00:15 | 339067.32 | 03-JUL-14:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 5435.43 | 0.00 | 01-JAN-02:15 | 0.00 | 29-JUN-17:15 |
Water:Plant | 5435.43 | 0.00 | 01-JAN-02:15 | 0.00 | 29-JUN-17:15 |
WaterSystems:Water | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:Water | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
MainsWater:Facility | 5435.43 | 0.00 | 01-JAN-02:15 | 0.00 | 29-JUN-17:15 |
MainsWater:Plant | 5435.43 | 0.00 | 01-JAN-02:15 | 0.00 | 29-JUN-17:15 |
WaterSystems:MainsWater | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:MainsWater | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
sub cat:WaterSystems:Water | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
sub cat:WaterSystems:MainsWater | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
HeatRejection:Water | 656.92 | 0.00 | 01-JAN-00:15 | 0.00 | 29-JUN-16:30 |
HeatRejection:MainsWater | 656.92 | 0.00 | 01-JAN-00:15 | 0.00 | 29-JUN-16:30 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 2335.57 | 569.94 | 27-AUG-01:15 | 285053.85 | 04-JAN-06:15 |
PlantLoopHeatingDemand:Plant | 1047.44 | 569.94 | 27-AUG-01:15 | 70834.93 | 25-FEB-07:45 |
WaterSystems:PlantLoopHeatingDemand | 1047.44 | 569.94 | 27-AUG-01:15 | 70834.93 | 25-FEB-07:45 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 6292.81 | 6991.66 | 11-JUN-03:00 | 807470.56 | 04-JAN-06:15 |
EnergyTransfer:Building | 1573.19 | 3062.46 | 28-AUG-20:15 | 220664.08 | 04-JAN-06:00 |
EnergyTransfer:Zone:G SW APARTMENT | 18.08 | 0.02 | 18-OCT-14:00 | 2680.39 | 04-JAN-08:15 |
Heating:EnergyTransfer | 880.83 | 0.00 | 26-MAR-15:15 | 220664.08 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 11.83 | 0.00 | 02-JAN-12:00 | 2680.39 | 04-JAN-08:15 |
Cooling:EnergyTransfer | 692.35 | 0.00 | 01-JAN-00:15 | 168381.34 | 18-JUN-13:45 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 6.25 | 0.00 | 01-JAN-00:15 | 2465.13 | 01-SEP-15:30 |
EnergyTransfer:Zone:G NW APARTMENT | 19.93 | 0.09 | 04-OCT-13:00 | 2866.51 | 04-JAN-08:30 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 15.77 | 0.00 | 08-FEB-15:45 | 2866.51 | 04-JAN-08:30 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 4.17 | 0.00 | 01-JAN-00:15 | 2065.98 | 24-JUL-17:30 |
EnergyTransfer:Zone:OFFICE | 22.82 | 0.27 | 01-NOV-12:00 | 3158.44 | 01-SEP-13:30 |
Heating:EnergyTransfer:Zone:OFFICE | 11.34 | 0.00 | 02-JAN-09:15 | 2794.59 | 24-DEC-08:00 |
Cooling:EnergyTransfer:Zone:OFFICE | 11.48 | 0.00 | 01-JAN-00:15 | 3158.44 | 01-SEP-13:30 |
EnergyTransfer:Zone:G NE APARTMENT | 19.69 | 0.01 | 19-MAY-11:15 | 2767.06 | 04-JAN-08:15 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 15.59 | 0.00 | 20-MAR-08:30 | 2767.06 | 04-JAN-08:15 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 4.10 | 0.00 | 01-JAN-00:15 | 1599.35 | 24-JUL-10:15 |
EnergyTransfer:Zone:G N1 APARTMENT | 12.98 | 0.02 | 31-AUG-11:15 | 1911.51 | 05-JAN-08:30 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 9.27 | 0.00 | 19-MAR-16:15 | 1911.51 | 05-JAN-08:30 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 3.70 | 0.00 | 01-JAN-00:15 | 1188.49 | 30-JUN-19:30 |
EnergyTransfer:Zone:G N2 APARTMENT | 12.96 | 0.02 | 31-AUG-11:15 | 1910.51 | 05-JAN-08:30 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 9.27 | 0.00 | 19-MAR-16:15 | 1910.51 | 05-JAN-08:30 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 3.69 | 0.00 | 01-JAN-00:15 | 1188.33 | 30-JUN-19:30 |
EnergyTransfer:Zone:G S1 APARTMENT | 11.72 | 0.02 | 20-AUG-08:15 | 1701.33 | 04-JAN-08:15 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 5.55 | 0.00 | 01-JAN-11:00 | 1701.33 | 04-JAN-08:15 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 6.16 | 0.00 | 01-JAN-00:15 | 1671.33 | 01-SEP-15:30 |
EnergyTransfer:Zone:G S2 APARTMENT | 11.71 | 0.05 | 14-AUG-21:00 | 1726.05 | 01-SEP-15:30 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 5.44 | 0.00 | 01-JAN-11:00 | 1694.36 | 04-JAN-08:15 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 6.27 | 0.00 | 01-JAN-00:15 | 1726.05 | 01-SEP-15:30 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F2 SW APARTMENT | 20.87 | 0.01 | 27-APR-23:15 | 3225.76 | 01-SEP-15:30 |
Heating:EnergyTransfer:Zone:F2 SW APARTMENT | 9.81 | 0.00 | 02-JAN-11:30 | 2808.21 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT | 11.06 | 0.00 | 01-JAN-00:15 | 3225.76 | 01-SEP-15:30 |
EnergyTransfer:Zone:F2 NW APARTMENT | 21.46 | 0.06 | 20-FEB-15:30 | 3111.80 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F2 NW APARTMENT | 14.35 | 0.00 | 08-FEB-14:00 | 3111.80 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT | 7.11 | 0.00 | 01-JAN-00:15 | 2731.88 | 30-JUN-19:30 |
EnergyTransfer:Zone:F2 SE APARTMENT | 20.96 | 0.01 | 01-NOV-20:45 | 2917.38 | 01-SEP-14:00 |
Heating:EnergyTransfer:Zone:F2 SE APARTMENT | 9.27 | 0.00 | 01-JAN-12:00 | 2766.74 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT | 11.68 | 0.00 | 01-JAN-00:15 | 2917.38 | 01-SEP-14:00 |
EnergyTransfer:Zone:F2 NE APARTMENT | 21.38 | 0.02 | 06-MAY-14:15 | 2973.49 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:F2 NE APARTMENT | 14.16 | 0.00 | 22-FEB-10:00 | 2973.49 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT | 7.22 | 0.00 | 01-JAN-00:15 | 2021.55 | 30-JUN-19:30 |
EnergyTransfer:Zone:F2 N1 APARTMENT | 12.85 | 0.01 | 14-SEP-16:45 | 1762.98 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT | 6.56 | 0.00 | 18-JAN-22:00 | 1762.98 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT | 6.29 | 0.00 | 01-JAN-00:15 | 1460.12 | 30-JUN-19:45 |
EnergyTransfer:Zone:F2 N2 APARTMENT | 12.84 | 0.02 | 23-JUN-09:30 | 1758.26 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT | 6.56 | 0.00 | 18-JAN-22:00 | 1758.26 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT | 6.28 | 0.00 | 01-JAN-00:15 | 1443.23 | 30-JUN-19:45 |
EnergyTransfer:Zone:F2 S1 APARTMENT | 14.21 | 0.02 | 18-SEP-20:30 | 2239.12 | 01-SEP-15:30 |
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT | 3.34 | 0.00 | 01-JAN-10:15 | 1480.04 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT | 10.87 | 0.00 | 01-JAN-00:15 | 2239.12 | 01-SEP-15:30 |
EnergyTransfer:Zone:F2 S2 APARTMENT | 14.26 | 0.02 | 14-JUL-05:45 | 2258.12 | 01-SEP-15:30 |
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT | 3.32 | 0.00 | 01-JAN-10:15 | 1476.78 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT | 10.94 | 0.00 | 01-JAN-00:15 | 2258.12 | 01-SEP-15:30 |
EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F3 SW APARTMENT | 21.70 | 0.04 | 01-NOV-23:15 | 3294.10 | 23-APR-16:00 |
Heating:EnergyTransfer:Zone:F3 SW APARTMENT | 9.82 | 0.00 | 02-JAN-11:30 | 2958.42 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT | 11.88 | 0.00 | 01-JAN-00:15 | 3294.10 | 23-APR-16:00 |
EnergyTransfer:Zone:F3 NW APARTMENT | 22.13 | 0.30 | 20-OCT-11:15 | 3325.92 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F3 NW APARTMENT | 14.35 | 0.00 | 08-FEB-14:00 | 3325.92 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT | 7.78 | 0.00 | 01-JAN-00:15 | 2777.17 | 30-JUN-19:30 |
EnergyTransfer:Zone:F3 SE APARTMENT | 21.62 | 0.19 | 20-FEB-09:45 | 2945.88 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:F3 SE APARTMENT | 9.65 | 0.00 | 02-JAN-09:45 | 2945.88 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT | 11.97 | 0.00 | 01-JAN-00:15 | 2837.03 | 01-SEP-14:00 |
EnergyTransfer:Zone:F3 NE APARTMENT | 22.03 | 0.00 | 23-AUG-07:00 | 3174.77 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F3 NE APARTMENT | 14.17 | 0.00 | 22-FEB-10:00 | 3174.77 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT | 7.86 | 0.00 | 01-JAN-00:15 | 2098.85 | 18-JUN-13:45 |
EnergyTransfer:Zone:F3 N1 APARTMENT | 13.28 | 0.03 | 24-MAR-15:45 | 1851.20 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT | 6.19 | 0.00 | 17-JAN-13:00 | 1851.20 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT | 7.09 | 0.00 | 01-JAN-00:15 | 1575.06 | 24-MAY-18:15 |
EnergyTransfer:Zone:F3 N2 APARTMENT | 13.26 | 0.03 | 06-SEP-12:45 | 1846.55 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT | 6.18 | 0.00 | 17-JAN-13:00 | 1846.55 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT | 7.08 | 0.00 | 01-JAN-00:15 | 1564.27 | 24-MAY-18:15 |
EnergyTransfer:Zone:F3 S1 APARTMENT | 15.20 | 0.01 | 26-AUG-07:00 | 2281.71 | 01-SEP-15:30 |
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT | 3.09 | 0.00 | 01-JAN-10:15 | 1515.22 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT | 12.11 | 0.00 | 01-JAN-00:15 | 2281.71 | 01-SEP-15:30 |
EnergyTransfer:Zone:F3 S2 APARTMENT | 15.21 | 0.08 | 19-MAY-11:15 | 2292.43 | 01-SEP-15:30 |
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT | 3.09 | 0.00 | 01-JAN-10:00 | 1514.47 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT | 12.13 | 0.00 | 01-JAN-00:15 | 2292.43 | 01-SEP-15:30 |
EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F4 SW APARTMENT | 22.28 | 0.06 | 19-SEP-13:45 | 3382.16 | 23-APR-16:00 |
Heating:EnergyTransfer:Zone:F4 SW APARTMENT | 10.37 | 0.00 | 02-JAN-11:45 | 3129.76 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT | 11.91 | 0.00 | 01-JAN-00:15 | 3382.16 | 23-APR-16:00 |
EnergyTransfer:Zone:F4 NW APARTMENT | 22.84 | 0.02 | 17-AUG-01:30 | 3546.65 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F4 NW APARTMENT | 14.97 | 0.00 | 08-FEB-14:00 | 3546.65 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT | 7.87 | 0.00 | 01-JAN-00:15 | 2795.46 | 30-JUN-19:30 |
EnergyTransfer:Zone:F4 SE APARTMENT | 22.16 | 0.10 | 21-NOV-10:45 | 3120.28 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:F4 SE APARTMENT | 10.25 | 0.00 | 02-JAN-09:45 | 3120.28 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT | 11.91 | 0.00 | 01-JAN-00:15 | 2840.73 | 25-AUG-12:00 |
EnergyTransfer:Zone:F4 NE APARTMENT | 22.73 | 0.06 | 07-MAY-13:00 | 3394.01 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F4 NE APARTMENT | 14.78 | 0.00 | 08-FEB-22:00 | 3394.01 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT | 7.95 | 0.00 | 01-JAN-00:15 | 2117.68 | 18-JUN-13:45 |
EnergyTransfer:Zone:F4 N1 APARTMENT | 13.67 | 0.02 | 12-AUG-17:45 | 1974.23 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT | 6.40 | 0.00 | 17-JAN-13:00 | 1974.23 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT | 7.27 | 0.00 | 01-JAN-00:15 | 1623.31 | 24-MAY-18:15 |
EnergyTransfer:Zone:F4 N2 APARTMENT | 13.66 | 0.00 | 31-JUL-18:15 | 1969.55 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT | 6.40 | 0.00 | 17-JAN-13:00 | 1969.55 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT | 7.26 | 0.00 | 01-JAN-00:15 | 1607.70 | 24-MAY-18:15 |
EnergyTransfer:Zone:F4 S1 APARTMENT | 15.56 | 0.01 | 03-NOV-15:15 | 2357.98 | 23-APR-16:00 |
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT | 3.26 | 0.00 | 01-JAN-10:15 | 1601.72 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT | 12.30 | 0.00 | 01-JAN-00:15 | 2357.98 | 23-APR-16:00 |
EnergyTransfer:Zone:F4 S2 APARTMENT | 15.56 | 0.03 | 19-MAY-18:00 | 2345.66 | 23-APR-16:00 |
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT | 3.26 | 0.00 | 01-JAN-10:15 | 1601.52 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT | 12.30 | 0.00 | 01-JAN-00:15 | 2345.66 | 23-APR-16:00 |
EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M SW APARTMENT | 22.74 | 0.08 | 20-FEB-23:15 | 3423.60 | 23-APR-16:00 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 10.77 | 0.00 | 02-JAN-11:45 | 3263.11 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 11.97 | 0.00 | 01-JAN-00:15 | 3423.60 | 23-APR-16:00 |
EnergyTransfer:Zone:M NW APARTMENT | 23.35 | 0.06 | 07-OCT-04:15 | 3716.33 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 15.36 | 0.00 | 08-FEB-14:00 | 3716.33 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 7.99 | 0.00 | 01-JAN-00:15 | 2834.78 | 30-JUN-19:30 |
EnergyTransfer:Zone:M SE APARTMENT | 22.60 | 0.01 | 21-MAR-21:45 | 3252.76 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 10.65 | 0.00 | 02-JAN-09:45 | 3252.76 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 11.95 | 0.00 | 01-JAN-00:15 | 2882.91 | 12-JUL-12:00 |
EnergyTransfer:Zone:M NE APARTMENT | 23.23 | 0.01 | 19-AUG-10:00 | 3562.86 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 15.16 | 0.00 | 08-FEB-22:00 | 3562.86 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 8.07 | 0.00 | 01-JAN-00:15 | 2154.82 | 18-JUN-13:45 |
EnergyTransfer:Zone:M N1 APARTMENT | 13.97 | 0.01 | 31-AUG-08:00 | 2065.78 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 6.51 | 0.00 | 17-JAN-13:00 | 2065.78 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 7.46 | 0.00 | 01-JAN-00:15 | 1664.83 | 24-MAY-18:15 |
EnergyTransfer:Zone:M N2 APARTMENT | 13.97 | 0.00 | 16-JUL-09:00 | 2061.08 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 6.51 | 0.00 | 17-JAN-13:00 | 2061.08 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 7.46 | 0.00 | 01-JAN-00:15 | 1649.22 | 24-MAY-18:15 |
EnergyTransfer:Zone:M S1 APARTMENT | 15.86 | 0.02 | 11-APR-15:45 | 2439.35 | 23-APR-16:00 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 3.39 | 0.00 | 01-JAN-10:15 | 1670.30 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 12.46 | 0.00 | 01-JAN-00:15 | 2439.35 | 23-APR-16:00 |
EnergyTransfer:Zone:M S2 APARTMENT | 15.85 | 0.04 | 12-NOV-11:00 | 2426.84 | 23-APR-16:00 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 3.39 | 0.00 | 01-JAN-10:15 | 1670.15 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 12.46 | 0.00 | 01-JAN-00:15 | 2426.84 | 23-APR-16:00 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F6 SW APARTMENT | 22.99 | 0.05 | 19-OCT-11:45 | 3440.49 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:F6 SW APARTMENT | 11.78 | 0.00 | 02-JAN-12:00 | 3440.49 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT | 11.21 | 0.00 | 01-JAN-00:15 | 3386.35 | 23-APR-16:00 |
EnergyTransfer:Zone:F6 NW APARTMENT | 24.00 | 0.04 | 01-OCT-12:45 | 3922.21 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F6 NW APARTMENT | 16.53 | 0.00 | 08-FEB-14:00 | 3922.21 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT | 7.46 | 0.00 | 01-JAN-00:15 | 2798.33 | 30-JUN-19:30 |
EnergyTransfer:Zone:F6 SE APARTMENT | 22.82 | 0.03 | 01-APR-14:00 | 3428.77 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:F6 SE APARTMENT | 11.64 | 0.00 | 02-JAN-11:30 | 3428.77 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT | 11.18 | 0.00 | 01-JAN-00:15 | 2867.56 | 12-JUL-12:00 |
EnergyTransfer:Zone:F6 NE APARTMENT | 23.85 | 0.00 | 06-JUN-07:45 | 3767.29 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F6 NE APARTMENT | 16.31 | 0.00 | 22-FEB-10:00 | 3767.29 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT | 7.54 | 0.00 | 01-JAN-00:15 | 2131.69 | 12-JUL-12:00 |
EnergyTransfer:Zone:F6 N1 APARTMENT | 14.18 | 0.01 | 28-APR-11:30 | 2202.20 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT | 7.25 | 0.00 | 17-JAN-13:00 | 2202.20 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT | 6.92 | 0.00 | 01-JAN-00:15 | 1632.41 | 24-MAY-18:15 |
EnergyTransfer:Zone:F6 N2 APARTMENT | 14.16 | 0.01 | 26-JUL-08:45 | 2197.46 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT | 7.25 | 0.00 | 17-JAN-13:00 | 2197.46 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT | 6.92 | 0.00 | 01-JAN-00:15 | 1616.90 | 24-MAY-18:15 |
EnergyTransfer:Zone:F6 S1 APARTMENT | 15.51 | 0.04 | 25-JUL-05:45 | 2409.00 | 23-APR-16:00 |
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT | 3.89 | 0.00 | 01-JAN-10:30 | 1789.70 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT | 11.61 | 0.00 | 01-JAN-00:15 | 2409.00 | 23-APR-16:00 |
EnergyTransfer:Zone:F6 S2 APARTMENT | 15.50 | 0.08 | 04-AUG-07:45 | 2416.20 | 23-APR-16:00 |
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT | 3.89 | 0.00 | 01-JAN-10:30 | 1789.52 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT | 11.61 | 0.00 | 01-JAN-00:15 | 2416.20 | 23-APR-16:00 |
EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F7 SW APARTMENT | 23.28 | 0.05 | 02-NOV-17:45 | 3582.73 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:F7 SW APARTMENT | 12.55 | 0.00 | 02-JAN-12:00 | 3582.73 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT | 10.73 | 0.00 | 01-JAN-00:15 | 3377.11 | 23-APR-16:00 |
EnergyTransfer:Zone:F7 NW APARTMENT | 24.55 | 0.03 | 20-OCT-11:15 | 4087.59 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F7 NW APARTMENT | 17.38 | 0.00 | 08-FEB-15:45 | 4087.59 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT | 7.16 | 0.00 | 01-JAN-00:15 | 2788.71 | 30-JUN-19:30 |
EnergyTransfer:Zone:F7 SE APARTMENT | 23.11 | 0.11 | 09-OCT-06:00 | 3569.95 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:F7 SE APARTMENT | 12.41 | 0.00 | 02-JAN-11:45 | 3569.95 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT | 10.70 | 0.00 | 01-JAN-00:15 | 2872.18 | 12-JUL-12:00 |
EnergyTransfer:Zone:F7 NE APARTMENT | 24.37 | 0.00 | 29-AUG-08:45 | 3931.77 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F7 NE APARTMENT | 17.14 | 0.00 | 22-FEB-10:00 | 3931.77 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT | 7.23 | 0.00 | 01-JAN-00:15 | 2132.11 | 12-JUL-12:00 |
EnergyTransfer:Zone:F7 N1 APARTMENT | 14.39 | 0.03 | 16-JUN-09:15 | 2307.92 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT | 7.78 | 0.00 | 17-JAN-13:00 | 2307.92 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT | 6.62 | 0.00 | 01-JAN-00:15 | 1624.62 | 24-MAY-18:15 |
EnergyTransfer:Zone:F7 N2 APARTMENT | 14.38 | 0.00 | 06-AUG-19:00 | 2303.15 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT | 7.77 | 0.00 | 17-JAN-13:00 | 2303.15 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT | 6.61 | 0.00 | 01-JAN-00:15 | 1614.25 | 24-MAY-18:15 |
EnergyTransfer:Zone:F7 S1 APARTMENT | 15.36 | 0.05 | 21-AUG-08:15 | 2400.34 | 23-APR-16:00 |
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT | 4.28 | 0.00 | 01-JAN-10:30 | 1884.08 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT | 11.08 | 0.00 | 01-JAN-00:15 | 2400.34 | 23-APR-16:00 |
EnergyTransfer:Zone:F7 S2 APARTMENT | 15.36 | 0.03 | 14-JUN-09:00 | 2406.43 | 23-APR-16:00 |
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT | 4.28 | 0.00 | 01-JAN-10:30 | 1883.88 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT | 11.08 | 0.00 | 01-JAN-00:15 | 2406.43 | 23-APR-16:00 |
EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F8 SW APARTMENT | 23.68 | 0.10 | 09-OCT-06:15 | 3723.75 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:F8 SW APARTMENT | 13.34 | 0.00 | 06-JAN-11:00 | 3723.75 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT | 10.33 | 0.00 | 01-JAN-00:15 | 3374.88 | 23-APR-16:00 |
EnergyTransfer:Zone:F8 NW APARTMENT | 25.18 | 0.07 | 14-APR-11:30 | 4247.27 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F8 NW APARTMENT | 18.25 | 0.00 | 08-FEB-16:00 | 4247.27 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT | 6.93 | 0.00 | 01-JAN-00:15 | 2793.11 | 30-JUN-19:30 |
EnergyTransfer:Zone:F8 SE APARTMENT | 23.50 | 0.15 | 01-NOV-22:45 | 3710.20 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:F8 SE APARTMENT | 13.20 | 0.00 | 02-JAN-12:00 | 3710.20 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT | 10.30 | 0.00 | 01-JAN-00:15 | 2882.82 | 12-JUL-12:00 |
EnergyTransfer:Zone:F8 NE APARTMENT | 24.98 | 0.01 | 09-MAY-04:00 | 4090.56 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F8 NE APARTMENT | 17.99 | 0.00 | 22-FEB-10:00 | 4090.56 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT | 6.99 | 0.00 | 01-JAN-00:15 | 2136.56 | 12-JUL-12:15 |
EnergyTransfer:Zone:F8 N1 APARTMENT | 14.73 | 0.02 | 31-JUL-08:00 | 2413.52 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT | 8.35 | 0.00 | 17-JAN-13:00 | 2413.52 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT | 6.38 | 0.00 | 01-JAN-00:15 | 1634.96 | 24-MAY-18:15 |
EnergyTransfer:Zone:F8 N2 APARTMENT | 14.72 | 0.01 | 11-SEP-18:15 | 2408.73 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT | 8.35 | 0.00 | 17-JAN-13:00 | 2408.73 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT | 6.37 | 0.00 | 01-JAN-00:15 | 1619.89 | 24-MAY-18:15 |
EnergyTransfer:Zone:F8 S1 APARTMENT | 15.33 | 0.03 | 12-APR-13:45 | 2400.19 | 23-APR-16:00 |
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT | 4.73 | 0.00 | 01-JAN-10:45 | 1984.70 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT | 10.60 | 0.00 | 01-JAN-00:15 | 2400.19 | 23-APR-16:00 |
EnergyTransfer:Zone:F8 S2 APARTMENT | 15.33 | 0.06 | 21-AUG-08:15 | 2403.56 | 23-APR-16:00 |
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT | 4.73 | 0.00 | 01-JAN-10:45 | 1984.50 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT | 10.61 | 0.00 | 01-JAN-00:15 | 2403.56 | 23-APR-16:00 |
EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F9 SW APARTMENT | 25.10 | 0.00 | 14-OCT-12:00 | 4013.16 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:F9 SW APARTMENT | 15.23 | 0.00 | 06-JAN-13:30 | 4013.16 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT | 9.87 | 0.00 | 01-JAN-00:15 | 3377.36 | 23-APR-16:00 |
EnergyTransfer:Zone:F9 NW APARTMENT | 27.04 | 0.02 | 28-OCT-17:45 | 4539.07 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F9 NW APARTMENT | 20.32 | 0.00 | 08-FEB-16:15 | 4539.07 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT | 6.72 | 0.00 | 01-JAN-00:15 | 2888.60 | 30-JUN-19:30 |
EnergyTransfer:Zone:F9 SE APARTMENT | 24.89 | 0.04 | 01-NOV-20:45 | 3999.05 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:F9 SE APARTMENT | 15.06 | 0.00 | 06-JAN-11:00 | 3999.05 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT | 9.82 | 0.00 | 01-JAN-00:15 | 2904.60 | 12-JUL-12:00 |
EnergyTransfer:Zone:F9 NE APARTMENT | 26.82 | 0.09 | 18-OCT-23:15 | 4375.91 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F9 NE APARTMENT | 20.04 | 0.00 | 22-FEB-10:00 | 4375.91 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT | 6.78 | 0.00 | 01-JAN-00:15 | 2165.76 | 12-JUL-12:00 |
EnergyTransfer:Zone:F9 N1 APARTMENT | 16.12 | 0.01 | 22-JUN-17:45 | 2647.45 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT | 10.02 | 0.00 | 29-JAN-17:15 | 2647.45 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT | 6.10 | 0.00 | 01-JAN-00:15 | 1706.08 | 24-MAY-18:15 |
EnergyTransfer:Zone:F9 N2 APARTMENT | 16.12 | 0.03 | 30-MAR-11:15 | 2642.40 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT | 10.02 | 0.00 | 29-JAN-17:15 | 2642.40 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT | 6.10 | 0.00 | 01-JAN-00:15 | 1695.66 | 24-MAY-18:15 |
EnergyTransfer:Zone:F9 S1 APARTMENT | 15.91 | 0.04 | 16-MAY-08:45 | 2377.07 | 23-APR-16:00 |
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT | 6.00 | 0.00 | 01-JAN-11:15 | 2229.73 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT | 9.91 | 0.00 | 01-JAN-00:15 | 2377.07 | 23-APR-16:00 |
EnergyTransfer:Zone:F9 S2 APARTMENT | 15.92 | 0.03 | 13-SEP-17:15 | 2366.03 | 23-APR-16:00 |
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT | 6.00 | 0.00 | 01-JAN-11:15 | 2229.60 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT | 9.91 | 0.00 | 01-JAN-00:15 | 2366.03 | 23-APR-16:00 |
EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:T SW APARTMENT | 33.32 | 0.00 | 17-MAY-04:15 | 5112.62 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 24.04 | 0.00 | 06-JAN-13:30 | 5112.62 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 9.28 | 0.00 | 01-JAN-00:15 | 4052.91 | 01-SEP-15:30 |
EnergyTransfer:Zone:T NW APARTMENT | 35.04 | 0.01 | 28-FEB-16:30 | 5295.48 | 04-JAN-12:00 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 28.64 | 0.00 | 08-FEB-14:00 | 5295.48 | 04-JAN-12:00 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 6.40 | 0.00 | 01-JAN-00:15 | 3387.61 | 29-JUL-16:30 |
EnergyTransfer:Zone:T SE APARTMENT | 32.83 | 0.01 | 04-OCT-16:00 | 5094.46 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 23.77 | 0.00 | 06-JAN-11:00 | 5094.46 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 9.06 | 0.00 | 01-JAN-00:15 | 3551.12 | 25-AUG-12:15 |
EnergyTransfer:Zone:T NE APARTMENT | 34.59 | 0.28 | 14-AUG-04:15 | 5184.93 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 28.28 | 0.00 | 17-MAR-15:45 | 5184.93 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 6.31 | 0.00 | 01-JAN-00:15 | 2602.90 | 12-JUL-12:00 |
EnergyTransfer:Zone:T N1 APARTMENT | 23.34 | 0.06 | 20-AUG-21:00 | 3435.17 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 17.81 | 0.00 | 08-FEB-14:00 | 3435.17 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 5.54 | 0.00 | 01-JAN-00:15 | 2018.63 | 11-JUL-15:45 |
EnergyTransfer:Zone:T N2 APARTMENT | 23.33 | 0.06 | 10-SEP-15:15 | 3434.98 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 17.81 | 0.00 | 08-FEB-14:00 | 3434.98 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 5.52 | 0.00 | 01-JAN-00:15 | 2017.96 | 11-JUL-15:45 |
EnergyTransfer:Zone:T S1 APARTMENT | 22.17 | 0.10 | 15-NOV-15:30 | 3331.29 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 13.65 | 0.00 | 01-JAN-12:00 | 3331.29 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 8.53 | 0.00 | 01-JAN-00:15 | 3091.07 | 24-MAY-13:30 |
EnergyTransfer:Zone:T S2 APARTMENT | 22.18 | 0.07 | 01-NOV-09:00 | 3331.04 | 04-JAN-06:00 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 13.65 | 0.00 | 01-JAN-12:00 | 3331.04 | 04-JAN-06:00 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 8.53 | 0.00 | 01-JAN-00:15 | 3099.80 | 24-MAY-13:30 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Plant | 2303.64 | 569.94 | 27-AUG-01:15 | 285346.32 | 04-JAN-06:15 |
WaterSystems:EnergyTransfer | 1047.43 | 569.94 | 27-AUG-01:15 | 70827.69 | 25-FEB-07:45 |
sub cat:WaterSystems:EnergyTransfer | 1047.43 | 569.94 | 27-AUG-01:15 | 70827.69 | 25-FEB-07:45 |
EnergyTransfer:HVAC | 2415.98 | 0.00 | 03-MAY-19:30 | 327758.32 | 04-JAN-06:00 |
CoolingCoils:EnergyTransfer | 747.26 | 0.00 | 01-JAN-00:15 | 268459.44 | 03-JUL-14:15 |
HeatingCoils:EnergyTransfer | 1668.73 | 0.00 | 10-APR-15:45 | 327758.32 | 04-JAN-06:00 |
PlantLoopHeatingDemand:HVAC | 1288.14 | 0.00 | 10-APR-15:45 | 223182.85 | 04-JAN-06:00 |
HeatingCoils:PlantLoopHeatingDemand | 1288.14 | 0.00 | 10-APR-15:45 | 223182.85 | 04-JAN-06:00 |
Boilers:EnergyTransfer | 1256.21 | 0.00 | 28-FEB-15:15 | 220588.08 | 04-JAN-06:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:12
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 11.834 | -6.250 | 0.000 | 0.000 | 3.881 | 2.413 | 12.213 | 16.702 | 0.000 | 0.100 | 0.000 | 0.000 | -15.853 | 0.000 | -8.257 | -16.783 |
G NW APARTMENT | 15.766 | -4.167 | 0.000 | 0.000 | 3.905 | 2.413 | 12.213 | 7.919 | 0.000 | 0.096 | 0.000 | 0.000 | -17.167 | 0.000 | -7.938 | -13.040 |
OFFICE | 11.339 | -11.484 | 0.000 | 0.000 | 0.541 | 21.954 | 7.547 | 16.472 | 0.000 | 0.032 | 0.000 | 0.000 | -15.735 | 0.000 | -5.289 | -25.376 |
G NE APARTMENT | 15.587 | -4.102 | 0.000 | 0.000 | 3.914 | 2.413 | 12.213 | 7.672 | 0.000 | 0.096 | 0.000 | 0.000 | -16.884 | 0.000 | -7.958 | -12.951 |
G N1 APARTMENT | 9.275 | -3.703 | 0.000 | 0.000 | 3.917 | 2.413 | 12.213 | 2.698 | 0.000 | 0.084 | 0.000 | 0.000 | -10.837 | 0.000 | -5.654 | -10.406 |
G N2 APARTMENT | 9.270 | -3.693 | 0.000 | 0.000 | 3.918 | 2.413 | 12.213 | 2.696 | 0.000 | 0.084 | 0.000 | 0.000 | -10.835 | 0.000 | -5.656 | -10.411 |
G S1 APARTMENT | 5.552 | -6.163 | 0.000 | 0.000 | 3.882 | 2.413 | 12.213 | 11.677 | 0.000 | 0.087 | 0.000 | 0.000 | -9.624 | 0.000 | -6.042 | -13.994 |
G S2 APARTMENT | 5.444 | -6.268 | 0.000 | 0.000 | 3.880 | 2.413 | 12.213 | 11.666 | 0.000 | 0.087 | 0.000 | 0.000 | -9.631 | 0.000 | -6.070 | -13.735 |
F2 SW APARTMENT | 9.809 | -11.062 | 0.000 | 0.000 | 3.827 | 2.413 | 12.213 | 16.095 | 0.000 | 0.128 | 0.000 | 0.000 | -16.704 | 0.000 | -11.230 | -5.488 |
F2 NW APARTMENT | 14.347 | -7.113 | 0.000 | 0.000 | 3.863 | 2.413 | 12.213 | 7.528 | 0.000 | 0.121 | 0.000 | 0.000 | -18.021 | 0.000 | -10.861 | -4.490 |
F2 SE APARTMENT | 9.274 | -11.681 | 0.000 | 0.000 | 3.825 | 2.413 | 12.213 | 15.880 | 0.000 | 0.128 | 0.000 | 0.000 | -16.526 | 0.000 | -11.308 | -4.217 |
F2 NE APARTMENT | 14.159 | -7.216 | 0.000 | 0.000 | 3.875 | 2.413 | 12.213 | 7.294 | 0.000 | 0.120 | 0.000 | 0.000 | -17.697 | 0.000 | -10.850 | -4.310 |
F2 N1 APARTMENT | 6.565 | -6.289 | 0.000 | 0.000 | 3.873 | 2.413 | 12.213 | 2.492 | 0.000 | 0.101 | 0.000 | 0.000 | -11.420 | 0.000 | -7.645 | -2.302 |
F2 N2 APARTMENT | 6.557 | -6.284 | 0.000 | 0.000 | 3.874 | 2.413 | 12.213 | 2.491 | 0.000 | 0.101 | 0.000 | 0.000 | -11.417 | 0.000 | -7.645 | -2.304 |
F2 S1 APARTMENT | 3.336 | -10.873 | 0.000 | 0.000 | 3.820 | 2.413 | 12.213 | 11.290 | 0.000 | 0.109 | 0.001 | 0.000 | -10.143 | 0.000 | -8.125 | -4.040 |
F2 S2 APARTMENT | 3.317 | -10.940 | 0.000 | 0.000 | 3.819 | 2.413 | 12.213 | 11.287 | 0.000 | 0.109 | 0.001 | 0.000 | -10.146 | 0.000 | -8.133 | -3.939 |
F3 SW APARTMENT | 9.817 | -11.882 | 0.000 | 0.000 | 3.819 | 2.413 | 12.213 | 15.860 | 0.000 | 0.167 | 0.001 | 0.000 | -16.988 | 0.000 | -12.888 | -2.530 |
F3 NW APARTMENT | 14.352 | -7.779 | 0.000 | 0.000 | 3.855 | 2.413 | 12.213 | 7.392 | 0.000 | 0.159 | 0.000 | 0.000 | -18.334 | 0.000 | -12.497 | -1.776 |
F3 SE APARTMENT | 9.651 | -11.972 | 0.000 | 0.000 | 3.822 | 2.413 | 12.213 | 15.680 | 0.000 | 0.167 | 0.000 | 0.000 | -16.755 | 0.000 | -12.931 | -2.288 |
F3 NE APARTMENT | 14.168 | -7.863 | 0.000 | 0.000 | 3.867 | 2.413 | 12.213 | 7.165 | 0.000 | 0.156 | 0.000 | 0.000 | -17.995 | 0.000 | -12.482 | -1.641 |
F3 N1 APARTMENT | 6.185 | -7.094 | 0.000 | 0.000 | 3.862 | 2.413 | 12.213 | 2.429 | 0.000 | 0.134 | 0.224 | 0.000 | -11.629 | 0.000 | -8.735 | -0.000 |
F3 N2 APARTMENT | 6.179 | -7.083 | 0.000 | 0.000 | 3.863 | 2.413 | 12.213 | 2.429 | 0.000 | 0.134 | 0.214 | 0.000 | -11.626 | 0.000 | -8.734 | -0.000 |
F3 S1 APARTMENT | 3.088 | -12.109 | 0.000 | 0.000 | 3.807 | 2.413 | 12.213 | 11.132 | 0.000 | 0.145 | 0.001 | 0.000 | -10.330 | 0.000 | -9.239 | -1.119 |
F3 S2 APARTMENT | 3.086 | -12.127 | 0.000 | 0.000 | 3.807 | 2.413 | 12.213 | 11.130 | 0.000 | 0.145 | 0.001 | 0.000 | -10.330 | 0.000 | -9.243 | -1.094 |
F4 SW APARTMENT | 10.370 | -11.913 | 0.000 | 0.000 | 3.818 | 2.413 | 12.213 | 15.717 | 0.000 | 0.181 | 0.001 | 0.000 | -17.143 | 0.000 | -13.997 | -1.658 |
F4 NW APARTMENT | 14.971 | -7.869 | 0.000 | 0.000 | 3.854 | 2.413 | 12.213 | 7.316 | 0.000 | 0.172 | 0.000 | 0.000 | -18.513 | 0.000 | -13.591 | -0.965 |
F4 SE APARTMENT | 10.249 | -11.909 | 0.000 | 0.000 | 3.822 | 2.413 | 12.213 | 15.548 | 0.000 | 0.180 | 0.000 | 0.000 | -16.895 | 0.000 | -14.034 | -1.587 |
F4 NE APARTMENT | 14.779 | -7.955 | 0.000 | 0.000 | 3.866 | 2.413 | 12.213 | 7.093 | 0.000 | 0.168 | 0.000 | 0.000 | -18.166 | 0.000 | -13.575 | -0.836 |
F4 N1 APARTMENT | 6.400 | -7.265 | 0.000 | 0.000 | 3.859 | 2.413 | 12.213 | 2.397 | 0.000 | 0.143 | 1.005 | 0.000 | -11.749 | 0.000 | -9.415 | -0.000 |
F4 N2 APARTMENT | 6.400 | -7.260 | 0.000 | 0.000 | 3.860 | 2.413 | 12.213 | 2.396 | 0.000 | 0.143 | 0.994 | 0.000 | -11.745 | 0.000 | -9.414 | -0.000 |
F4 S1 APARTMENT | 3.262 | -12.295 | 0.000 | 0.000 | 3.804 | 2.413 | 12.213 | 11.036 | 0.000 | 0.156 | 0.000 | 0.000 | -10.429 | 0.000 | -9.930 | -0.230 |
F4 S2 APARTMENT | 3.261 | -12.296 | 0.000 | 0.000 | 3.804 | 2.413 | 12.213 | 11.035 | 0.000 | 0.156 | 0.002 | 0.000 | -10.428 | 0.000 | -9.933 | -0.224 |
M SW APARTMENT | 10.772 | -11.966 | 0.000 | 0.000 | 3.818 | 2.413 | 12.213 | 15.604 | 0.000 | 0.191 | 0.000 | 0.000 | -17.271 | 0.000 | -15.031 | -0.744 |
M NW APARTMENT | 15.362 | -7.987 | 0.000 | 0.000 | 3.854 | 2.413 | 12.213 | 7.257 | 0.000 | 0.181 | 0.000 | 0.000 | -18.660 | 0.000 | -14.601 | -0.032 |
M SE APARTMENT | 10.652 | -11.945 | 0.000 | 0.000 | 3.822 | 2.413 | 12.213 | 15.441 | 0.000 | 0.190 | 0.000 | 0.000 | -17.015 | 0.000 | -15.068 | -0.703 |
M NE APARTMENT | 15.160 | -8.071 | 0.000 | 0.000 | 3.866 | 2.413 | 12.213 | 7.038 | 0.000 | 0.177 | 0.094 | 0.000 | -18.306 | 0.000 | -14.583 | -0.000 |
M N1 APARTMENT | 6.511 | -7.461 | 0.000 | 0.000 | 3.857 | 2.413 | 12.213 | 2.372 | 0.000 | 0.150 | 1.869 | 0.000 | -11.846 | 0.000 | -10.079 | -0.000 |
M N2 APARTMENT | 6.512 | -7.455 | 0.000 | 0.000 | 3.858 | 2.413 | 12.213 | 2.372 | 0.000 | 0.149 | 1.858 | 0.000 | -11.842 | 0.000 | -10.077 | -0.000 |
M S1 APARTMENT | 3.395 | -12.461 | 0.000 | 0.000 | 3.803 | 2.413 | 12.213 | 10.962 | 0.000 | 0.164 | 0.637 | 0.000 | -10.508 | 0.000 | -10.616 | -0.000 |
M S2 APARTMENT | 3.395 | -12.459 | 0.000 | 0.000 | 3.803 | 2.413 | 12.213 | 10.960 | 0.000 | 0.164 | 0.637 | 0.000 | -10.507 | 0.000 | -10.619 | -0.000 |
F6 SW APARTMENT | 11.779 | -11.212 | 0.000 | 0.000 | 3.825 | 2.413 | 12.213 | 15.545 | 0.000 | 0.199 | 0.001 | 0.000 | -17.312 | 0.000 | -15.882 | -1.568 |
F6 NW APARTMENT | 16.533 | -7.465 | 0.000 | 0.000 | 3.861 | 2.413 | 12.213 | 7.240 | 0.000 | 0.189 | 0.000 | 0.000 | -18.714 | 0.000 | -15.410 | -0.859 |
F6 SE APARTMENT | 11.644 | -11.176 | 0.000 | 0.000 | 3.829 | 2.413 | 12.213 | 15.385 | 0.000 | 0.199 | 0.001 | 0.000 | -17.052 | 0.000 | -15.922 | -1.533 |
F6 NE APARTMENT | 16.308 | -7.544 | 0.000 | 0.000 | 3.872 | 2.413 | 12.213 | 7.024 | 0.000 | 0.184 | 0.000 | 0.000 | -18.354 | 0.000 | -15.391 | -0.725 |
F6 N1 APARTMENT | 7.251 | -6.924 | 0.000 | 0.000 | 3.864 | 2.413 | 12.213 | 2.370 | 0.000 | 0.156 | 1.115 | 0.000 | -11.877 | 0.000 | -10.581 | -0.000 |
F6 N2 APARTMENT | 7.248 | -6.916 | 0.000 | 0.000 | 3.865 | 2.413 | 12.213 | 2.370 | 0.000 | 0.155 | 1.105 | 0.000 | -11.873 | 0.000 | -10.580 | -0.000 |
F6 S1 APARTMENT | 3.893 | -11.615 | 0.000 | 0.000 | 3.810 | 2.413 | 12.213 | 10.922 | 0.000 | 0.170 | 0.000 | 0.000 | -10.530 | 0.000 | -11.162 | -0.113 |
F6 S2 APARTMENT | 3.892 | -11.612 | 0.000 | 0.000 | 3.810 | 2.413 | 12.213 | 10.920 | 0.000 | 0.171 | 0.000 | 0.000 | -10.529 | 0.000 | -11.165 | -0.113 |
F7 SW APARTMENT | 12.548 | -10.734 | 0.000 | 0.000 | 3.829 | 2.413 | 12.213 | 15.489 | 0.000 | 0.206 | 0.002 | 0.000 | -17.359 | 0.000 | -16.637 | -1.968 |
F7 NW APARTMENT | 17.383 | -7.162 | 0.000 | 0.000 | 3.866 | 2.413 | 12.213 | 7.220 | 0.000 | 0.195 | 0.000 | 0.000 | -18.771 | 0.000 | -16.132 | -1.224 |
F7 SE APARTMENT | 12.408 | -10.699 | 0.000 | 0.000 | 3.834 | 2.413 | 12.213 | 15.332 | 0.000 | 0.206 | 0.000 | 0.000 | -17.095 | 0.000 | -16.679 | -1.932 |
F7 NE APARTMENT | 17.140 | -7.234 | 0.000 | 0.000 | 3.878 | 2.413 | 12.213 | 7.006 | 0.000 | 0.190 | 0.000 | 0.000 | -18.407 | 0.000 | -16.110 | -1.088 |
F7 N1 APARTMENT | 7.775 | -6.617 | 0.000 | 0.000 | 3.869 | 2.413 | 12.213 | 2.366 | 0.000 | 0.161 | 0.763 | 0.000 | -11.911 | 0.000 | -11.033 | -0.000 |
F7 N2 APARTMENT | 7.772 | -6.612 | 0.000 | 0.000 | 3.871 | 2.413 | 12.213 | 2.366 | 0.000 | 0.160 | 0.756 | 0.000 | -11.907 | 0.000 | -11.031 | -0.000 |
F7 S1 APARTMENT | 4.283 | -11.076 | 0.000 | 0.000 | 3.815 | 2.413 | 12.213 | 10.884 | 0.000 | 0.176 | 0.000 | 0.000 | -10.556 | 0.000 | -11.648 | -0.503 |
F7 S2 APARTMENT | 4.285 | -11.075 | 0.000 | 0.000 | 3.815 | 2.413 | 12.213 | 10.883 | 0.000 | 0.176 | 0.000 | 0.000 | -10.555 | 0.000 | -11.651 | -0.503 |
F8 SW APARTMENT | 13.342 | -10.333 | 0.000 | 0.000 | 3.834 | 2.413 | 12.213 | 15.441 | 0.000 | 0.213 | 0.001 | 0.000 | -17.397 | 0.000 | -17.330 | -2.396 |
F8 NW APARTMENT | 18.245 | -6.929 | 0.000 | 0.000 | 3.870 | 2.413 | 12.213 | 7.202 | 0.000 | 0.202 | 0.000 | 0.000 | -18.820 | 0.000 | -16.796 | -1.601 |
F8 SE APARTMENT | 13.197 | -10.302 | 0.000 | 0.000 | 3.838 | 2.413 | 12.213 | 15.287 | 0.000 | 0.212 | 0.001 | 0.000 | -17.130 | 0.000 | -17.373 | -2.355 |
F8 NE APARTMENT | 17.990 | -6.992 | 0.000 | 0.000 | 3.882 | 2.413 | 12.213 | 6.991 | 0.000 | 0.196 | 0.000 | 0.000 | -18.453 | 0.000 | -16.772 | -1.468 |
F8 N1 APARTMENT | 8.349 | -6.377 | 0.000 | 0.000 | 3.874 | 2.413 | 12.213 | 2.362 | 0.000 | 0.165 | 0.392 | 0.000 | -11.938 | 0.000 | -11.453 | -0.000 |
F8 N2 APARTMENT | 8.350 | -6.373 | 0.000 | 0.000 | 3.876 | 2.413 | 12.213 | 2.362 | 0.000 | 0.165 | 0.380 | 0.000 | -11.934 | 0.000 | -11.451 | -0.001 |
F8 S1 APARTMENT | 4.727 | -10.604 | 0.000 | 0.000 | 3.820 | 2.413 | 12.213 | 10.853 | 0.000 | 0.181 | 0.000 | 0.000 | -10.575 | 0.000 | -12.097 | -0.930 |
F8 S2 APARTMENT | 4.730 | -10.605 | 0.000 | 0.000 | 3.820 | 2.413 | 12.213 | 10.851 | 0.000 | 0.182 | 0.001 | 0.000 | -10.574 | 0.000 | -12.100 | -0.929 |
F9 SW APARTMENT | 15.231 | -9.866 | 0.000 | 0.000 | 3.840 | 2.413 | 12.213 | 15.421 | 0.000 | 0.221 | 0.000 | 0.000 | -17.380 | 0.000 | -17.931 | -4.162 |
F9 NW APARTMENT | 20.323 | -6.718 | 0.000 | 0.000 | 3.875 | 2.413 | 12.213 | 7.200 | 0.000 | 0.209 | 0.000 | 0.000 | -18.817 | 0.000 | -17.375 | -3.323 |
F9 SE APARTMENT | 15.064 | -9.824 | 0.000 | 0.000 | 3.845 | 2.413 | 12.213 | 15.270 | 0.000 | 0.220 | 0.000 | 0.000 | -17.113 | 0.000 | -17.979 | -4.109 |
F9 NE APARTMENT | 20.044 | -6.779 | 0.000 | 0.000 | 3.888 | 2.413 | 12.213 | 6.990 | 0.000 | 0.202 | 0.000 | 0.000 | -18.448 | 0.000 | -17.351 | -3.170 |
F9 N1 APARTMENT | 10.019 | -6.103 | 0.000 | 0.000 | 3.880 | 2.413 | 12.213 | 2.366 | 0.000 | 0.172 | 0.000 | 0.000 | -11.928 | 0.000 | -11.811 | -1.221 |
F9 N2 APARTMENT | 10.017 | -6.100 | 0.000 | 0.000 | 3.881 | 2.413 | 12.213 | 2.365 | 0.000 | 0.172 | 0.000 | 0.000 | -11.925 | 0.000 | -11.810 | -1.226 |
F9 S1 APARTMENT | 5.999 | -9.912 | 0.000 | 0.000 | 3.828 | 2.413 | 12.213 | 10.841 | 0.000 | 0.188 | 0.000 | 0.000 | -10.558 | 0.000 | -12.475 | -2.538 |
F9 S2 APARTMENT | 6.003 | -9.914 | 0.000 | 0.000 | 3.828 | 2.413 | 12.213 | 10.839 | 0.000 | 0.188 | 0.000 | 0.000 | -10.556 | 0.000 | -12.479 | -2.536 |
T SW APARTMENT | 24.037 | -9.282 | 0.000 | 0.000 | 3.872 | 2.413 | 12.213 | 15.272 | 0.000 | 0.225 | 0.000 | 0.000 | -16.803 | 0.000 | -18.414 | -13.532 |
T NW APARTMENT | 28.636 | -6.398 | 0.000 | 0.000 | 3.898 | 2.413 | 12.213 | 7.087 | 0.000 | 0.212 | 0.000 | 0.000 | -18.285 | 0.000 | -17.908 | -11.868 |
T SE APARTMENT | 23.771 | -9.056 | 0.000 | 0.000 | 3.877 | 2.413 | 12.213 | 15.148 | 0.000 | 0.224 | 0.000 | 0.000 | -16.564 | 0.000 | -18.474 | -13.551 |
T NE APARTMENT | 28.276 | -6.313 | 0.000 | 0.000 | 3.911 | 2.413 | 12.213 | 6.906 | 0.000 | 0.206 | 0.000 | 0.000 | -17.945 | 0.000 | -17.891 | -11.775 |
T N1 APARTMENT | 17.805 | -5.537 | 0.000 | 0.000 | 3.905 | 2.413 | 12.213 | 2.338 | 0.000 | 0.174 | 0.000 | 0.000 | -11.574 | 0.000 | -12.128 | -9.610 |
T N2 APARTMENT | 17.808 | -5.524 | 0.000 | 0.000 | 3.906 | 2.413 | 12.213 | 2.336 | 0.000 | 0.174 | 0.000 | 0.000 | -11.569 | 0.000 | -12.132 | -9.624 |
T S1 APARTMENT | 13.646 | -8.528 | 0.000 | 0.000 | 3.861 | 2.413 | 12.213 | 10.767 | 0.000 | 0.193 | 0.000 | 0.000 | -10.234 | 0.000 | -12.780 | -11.550 |
T S2 APARTMENT | 13.651 | -8.533 | 0.000 | 0.000 | 3.861 | 2.413 | 12.213 | 10.764 | 0.000 | 0.193 | 0.000 | 0.000 | -10.232 | 0.000 | -12.786 | -11.545 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18.529 | 0.000 | 3.521 | 0.000 | 0.274 | 52.019 | 0.000 | -3.624 | 0.000 | -70.720 | -0.000 |
F2 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18.529 | 0.000 | 1.568 | 0.000 | 0.003 | 0.000 | 0.000 | -2.185 | 0.000 | -1.352 | -16.563 |
F3 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18.529 | 0.000 | 1.530 | 0.000 | 0.003 | 0.000 | 0.000 | -2.270 | 0.000 | -1.637 | -16.155 |
F4 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18.529 | 0.000 | 1.510 | 0.000 | 0.003 | 0.000 | 0.000 | -2.309 | 0.000 | -1.844 | -15.889 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 37.059 | 0.000 | 1.486 | 0.000 | 0.002 | 0.000 | 0.000 | -2.359 | 0.000 | -2.066 | -34.122 |
F6 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18.529 | 0.000 | 1.494 | 0.000 | 0.004 | 0.000 | 0.000 | -2.332 | 0.000 | -2.139 | -15.555 |
F7 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18.529 | 0.000 | 1.494 | 0.000 | 0.004 | 0.000 | 0.000 | -2.327 | 0.000 | -2.246 | -15.454 |
F8 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18.529 | 0.000 | 1.491 | 0.000 | 0.004 | 0.000 | 0.000 | -2.327 | 0.000 | -2.347 | -15.350 |
F9 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18.529 | 0.000 | 1.492 | 0.000 | 0.004 | 0.000 | 0.000 | -2.316 | 0.000 | -2.429 | -15.280 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18.529 | 7.937 | 1.462 | 0.000 | 0.001 | 0.000 | 0.000 | -2.239 | 0.000 | -2.521 | -23.169 |
Total Facility | 880.805 | -692.340 | 0.000 | 0.000 | 304.967 | 416.414 | 980.287 | 743.248 | 0.000 | 13.340 | 64.078 | 0.000 | -1167.497 | 0.000 | -1073.390 | -469.901 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 01-SEP-15:30 | 0.00 | -2465.00 | 0.00 | 0.00 | 48.21 | 100.83 | 470.89 | 4193.33 | 0.00 | 123.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2471.42 |
G NW APARTMENT | 24-JUL-17:23 | 0.00 | -2067.40 | 0.00 | 0.00 | 141.82 | 194.45 | 588.62 | 2727.76 | 0.00 | 28.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1613.83 |
OFFICE | 01-SEP-13:30 | 0.00 | -3158.32 | 0.00 | 0.00 | 65.20 | 1622.33 | 544.91 | 3451.37 | 0.00 | 4.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2529.92 |
G NE APARTMENT | 24-JUL-10:15 | 0.00 | -1599.11 | 0.00 | 0.00 | 40.76 | 28.81 | 412.03 | 2006.76 | 0.00 | 234.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1123.50 |
G N1 APARTMENT | 30-JUN-19:30 | 0.00 | -1188.39 | 0.00 | 0.00 | 141.83 | 230.46 | 523.87 | 686.58 | 0.00 | 152.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -547.06 |
G N2 APARTMENT | 30-JUN-19:30 | 0.00 | -1188.23 | 0.00 | 0.00 | 141.83 | 230.46 | 523.87 | 687.29 | 0.00 | 155.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -550.33 |
G S1 APARTMENT | 01-SEP-15:30 | 0.00 | -1671.24 | 0.00 | 0.00 | 48.22 | 100.83 | 470.89 | 1875.23 | 0.00 | 126.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -950.71 |
G S2 APARTMENT | 01-SEP-15:30 | 0.00 | -1725.95 | 0.00 | 0.00 | 48.34 | 100.83 | 470.89 | 1875.10 | 0.00 | 131.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -900.39 |
F2 SW APARTMENT | 01-SEP-15:30 | 0.00 | -3225.53 | 0.00 | 0.00 | 48.61 | 100.83 | 470.89 | 4149.85 | 0.00 | 159.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1703.64 |
F2 NW APARTMENT | 30-JUN-19:30 | 0.00 | -2732.11 | 0.00 | 0.00 | 140.74 | 230.46 | 523.87 | 1579.26 | 0.00 | 178.72 | 79.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 SE APARTMENT | 01-SEP-14:00 | 0.00 | -2917.38 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 3013.93 | 0.00 | 140.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -689.60 |
F2 NE APARTMENT | 30-JUN-19:30 | 0.00 | -2021.61 | 0.00 | 0.00 | 141.56 | 230.46 | 523.87 | 713.74 | 0.00 | 182.50 | 229.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 N1 APARTMENT | 30-JUN-20:08 | 0.00 | -1464.34 | 0.00 | 0.00 | 160.07 | 158.44 | 500.33 | 0.00 | 0.00 | 0.00 | 847.37 | 0.00 | -109.39 | 0.00 | -92.47 | 0.00 |
F2 N2 APARTMENT | 30-JUN-20:08 | 0.00 | -1448.27 | 0.00 | 0.00 | 160.06 | 158.44 | 500.33 | 0.00 | 0.00 | 0.00 | 831.22 | 0.00 | -109.13 | 0.00 | -92.64 | 0.00 |
F2 S1 APARTMENT | 01-SEP-15:30 | 0.00 | -2238.96 | 0.00 | 0.00 | 48.35 | 100.83 | 470.89 | 1849.80 | 0.00 | 150.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -381.55 |
F2 S2 APARTMENT | 01-SEP-15:30 | 0.00 | -2257.96 | 0.00 | 0.00 | 48.40 | 100.83 | 470.89 | 1849.87 | 0.00 | 152.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -364.68 |
F3 SW APARTMENT | 23-APR-16:00 | 0.00 | -3294.21 | 0.00 | 0.00 | 48.90 | 100.83 | 470.89 | 3350.43 | 0.00 | 738.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1415.38 |
F3 NW APARTMENT | 30-JUN-19:30 | 0.00 | -2777.46 | 0.00 | 0.00 | 140.72 | 230.46 | 523.87 | 1568.44 | 0.00 | 194.39 | 119.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 SE APARTMENT | 01-SEP-14:00 | 0.00 | -2837.02 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 2995.81 | 0.00 | 157.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -768.03 |
F3 NE APARTMENT | 18-JUN-13:45 | 0.00 | -2099.43 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 1140.90 | 0.00 | 588.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -82.57 |
F3 N1 APARTMENT | 24-MAY-18:15 | 0.00 | -1574.86 | 0.00 | 0.00 | 141.82 | 230.46 | 547.42 | 515.88 | 0.00 | 273.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -134.61 |
F3 N2 APARTMENT | 24-MAY-18:15 | 0.00 | -1564.06 | 0.00 | 0.00 | 141.82 | 230.46 | 547.42 | 516.08 | 0.00 | 273.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -145.60 |
F3 S1 APARTMENT | 01-SEP-15:30 | 0.00 | -2281.53 | 0.00 | 0.00 | 48.37 | 100.83 | 470.89 | 1836.66 | 0.00 | 163.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -338.79 |
F3 S2 APARTMENT | 01-SEP-15:30 | 0.00 | -2292.25 | 0.00 | 0.00 | 48.41 | 100.83 | 470.89 | 1836.81 | 0.00 | 165.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -330.11 |
F4 SW APARTMENT | 23-APR-16:00 | 0.00 | -3382.28 | 0.00 | 0.00 | 48.90 | 100.83 | 470.89 | 3326.46 | 0.00 | 806.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1371.48 |
F4 NW APARTMENT | 30-JUN-19:30 | 0.00 | -2795.79 | 0.00 | 0.00 | 140.71 | 230.46 | 523.87 | 1560.87 | 0.00 | 205.97 | 133.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 SE APARTMENT | 25-AUG-12:00 | 0.00 | -2840.42 | 0.00 | 0.00 | 40.76 | 28.81 | 406.15 | 3057.34 | 0.00 | 291.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -984.39 |
F4 NE APARTMENT | 18-JUN-13:45 | 0.00 | -2118.32 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 1135.18 | 0.00 | 636.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -105.36 |
F4 N1 APARTMENT | 24-MAY-18:15 | 0.00 | -1623.11 | 0.00 | 0.00 | 141.82 | 230.46 | 547.42 | 512.79 | 0.00 | 289.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -99.05 |
F4 N2 APARTMENT | 24-MAY-18:15 | 0.00 | -1607.50 | 0.00 | 0.00 | 141.82 | 230.46 | 547.42 | 512.99 | 0.00 | 289.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -114.40 |
F4 S1 APARTMENT | 23-APR-16:00 | 0.00 | -2358.09 | 0.00 | 0.00 | 48.90 | 100.83 | 470.89 | 1048.80 | 0.00 | 773.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -85.14 |
F4 S2 APARTMENT | 23-APR-16:00 | 0.00 | -2345.76 | 0.00 | 0.00 | 48.90 | 100.83 | 470.89 | 1048.98 | 0.00 | 773.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -97.64 |
M SW APARTMENT | 23-APR-16:00 | 0.00 | -3423.73 | 0.00 | 0.00 | 48.90 | 100.83 | 470.89 | 3308.92 | 0.00 | 857.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1363.50 |
M NW APARTMENT | 30-JUN-19:30 | 0.00 | -2835.15 | 0.00 | 0.00 | 140.73 | 230.46 | 523.87 | 1554.28 | 0.00 | 215.48 | 170.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M SE APARTMENT | 12-JUL-12:00 | 0.00 | -2882.49 | 0.00 | 0.00 | 40.75 | 28.81 | 406.15 | 2539.99 | 0.00 | 588.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -721.63 |
M NE APARTMENT | 18-JUN-13:45 | 0.00 | -2155.50 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 1130.19 | 0.00 | 674.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -100.86 |
M N1 APARTMENT | 24-MAY-18:15 | 0.00 | -1664.63 | 0.00 | 0.00 | 141.82 | 230.46 | 547.42 | 510.28 | 0.00 | 302.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -67.61 |
M N2 APARTMENT | 24-MAY-18:15 | 0.00 | -1649.02 | 0.00 | 0.00 | 141.82 | 230.46 | 547.42 | 510.49 | 0.00 | 301.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -82.93 |
M S1 APARTMENT | 23-APR-16:00 | 0.00 | -2439.45 | 0.00 | 0.00 | 48.90 | 100.83 | 470.89 | 1042.09 | 0.00 | 829.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -52.62 |
M S2 APARTMENT | 23-APR-16:00 | 0.00 | -2426.94 | 0.00 | 0.00 | 48.90 | 100.83 | 470.89 | 1042.27 | 0.00 | 829.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -65.30 |
F6 SW APARTMENT | 23-APR-16:00 | 0.00 | -3386.47 | 0.00 | 0.00 | 48.90 | 100.83 | 470.89 | 3297.48 | 0.00 | 901.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1433.62 |
F6 NW APARTMENT | 30-JUN-19:30 | 0.00 | -2798.72 | 0.00 | 0.00 | 140.69 | 230.46 | 523.87 | 1550.07 | 0.00 | 222.15 | 131.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 SE APARTMENT | 12-JUL-12:00 | 0.00 | -2867.13 | 0.00 | 0.00 | 40.75 | 28.81 | 406.15 | 2531.29 | 0.00 | 618.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -758.54 |
F6 NE APARTMENT | 12-JUL-12:00 | 0.00 | -2131.33 | 0.00 | 0.00 | 40.75 | 28.81 | 406.15 | 1141.75 | 0.00 | 618.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -104.74 |
F6 N1 APARTMENT | 24-MAY-18:15 | 0.00 | -1632.20 | 0.00 | 0.00 | 141.82 | 230.46 | 547.42 | 509.50 | 0.00 | 312.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -109.53 |
F6 N2 APARTMENT | 24-MAY-18:15 | 0.00 | -1616.70 | 0.00 | 0.00 | 141.82 | 230.46 | 547.42 | 509.70 | 0.00 | 312.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -124.72 |
F6 S1 APARTMENT | 23-APR-16:00 | 0.00 | -2409.10 | 0.00 | 0.00 | 48.90 | 100.83 | 470.89 | 1038.33 | 0.00 | 870.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -120.68 |
F6 S2 APARTMENT | 23-APR-16:00 | 0.00 | -2416.30 | 0.00 | 0.00 | 48.90 | 100.83 | 470.89 | 1038.51 | 0.00 | 875.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -118.20 |
F7 SW APARTMENT | 23-APR-16:00 | 0.00 | -3377.24 | 0.00 | 0.00 | 48.90 | 100.83 | 470.89 | 3287.70 | 0.00 | 942.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1473.83 |
F7 NW APARTMENT | 30-JUN-19:30 | 0.00 | -2789.12 | 0.00 | 0.00 | 140.67 | 230.46 | 523.87 | 1545.94 | 0.00 | 227.89 | 120.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 SE APARTMENT | 12-JUL-12:00 | 0.00 | -2871.74 | 0.00 | 0.00 | 40.76 | 28.81 | 406.15 | 2523.33 | 0.00 | 644.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -771.71 |
F7 NE APARTMENT | 12-JUL-12:00 | 0.00 | -2131.74 | 0.00 | 0.00 | 40.75 | 28.81 | 406.15 | 1139.87 | 0.00 | 642.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -126.46 |
F7 N1 APARTMENT | 24-MAY-18:15 | 0.00 | -1624.41 | 0.00 | 0.00 | 141.82 | 230.46 | 547.42 | 508.46 | 0.00 | 321.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -125.38 |
F7 N2 APARTMENT | 24-MAY-18:15 | 0.00 | -1614.04 | 0.00 | 0.00 | 141.82 | 230.46 | 547.42 | 508.66 | 0.00 | 321.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -135.99 |
F7 S1 APARTMENT | 23-APR-16:00 | 0.00 | -2400.44 | 0.00 | 0.00 | 48.90 | 100.83 | 470.89 | 1035.01 | 0.00 | 908.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -163.24 |
F7 S2 APARTMENT | 23-APR-16:00 | 0.00 | -2406.52 | 0.00 | 0.00 | 48.90 | 100.83 | 470.89 | 1035.19 | 0.00 | 912.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -161.73 |
F8 SW APARTMENT | 23-APR-16:00 | 0.00 | -3374.99 | 0.00 | 0.00 | 48.90 | 100.83 | 470.89 | 3279.72 | 0.00 | 982.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1507.41 |
F8 NW APARTMENT | 30-JUN-19:30 | 0.00 | -2793.55 | 0.00 | 0.00 | 140.66 | 230.46 | 523.87 | 1541.88 | 0.00 | 232.72 | 123.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 SE APARTMENT | 12-JUL-12:00 | 0.00 | -2882.37 | 0.00 | 0.00 | 40.76 | 28.81 | 406.15 | 2516.18 | 0.00 | 666.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -776.17 |
F8 NE APARTMENT | 12-JUL-12:15 | 0.00 | -2136.43 | 0.00 | 0.00 | 40.72 | 28.81 | 388.49 | 1165.26 | 0.00 | 643.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -130.22 |
F8 N1 APARTMENT | 24-MAY-18:15 | 0.00 | -1634.74 | 0.00 | 0.00 | 141.82 | 230.46 | 547.42 | 507.34 | 0.00 | 330.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -122.92 |
F8 N2 APARTMENT | 24-MAY-18:15 | 0.00 | -1619.67 | 0.00 | 0.00 | 141.82 | 230.46 | 547.42 | 507.54 | 0.00 | 330.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -137.64 |
F8 S1 APARTMENT | 23-APR-16:00 | 0.00 | -2400.29 | 0.00 | 0.00 | 48.90 | 100.83 | 470.89 | 1032.40 | 0.00 | 944.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -197.11 |
F8 S2 APARTMENT | 23-APR-16:00 | 0.00 | -2403.66 | 0.00 | 0.00 | 48.90 | 100.83 | 470.89 | 1032.57 | 0.00 | 948.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -197.69 |
F9 SW APARTMENT | 23-APR-16:00 | 0.00 | -3377.46 | 0.00 | 0.00 | 48.90 | 100.83 | 470.89 | 3274.02 | 0.00 | 1026.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1543.90 |
F9 NW APARTMENT | 30-JUN-19:30 | 0.00 | -2889.09 | 0.00 | 0.00 | 140.56 | 230.46 | 523.87 | 1534.81 | 0.00 | 235.15 | 224.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 SE APARTMENT | 12-JUL-12:00 | 0.00 | -2904.14 | 0.00 | 0.00 | 40.76 | 28.81 | 406.15 | 2509.47 | 0.00 | 686.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -767.12 |
F9 NE APARTMENT | 12-JUL-12:00 | 0.00 | -2165.38 | 0.00 | 0.00 | 40.75 | 28.81 | 406.15 | 1135.86 | 0.00 | 683.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -129.90 |
F9 N1 APARTMENT | 24-MAY-18:15 | 0.00 | -1705.84 | 0.00 | 0.00 | 141.82 | 230.46 | 547.42 | 505.09 | 0.00 | 340.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -59.24 |
F9 N2 APARTMENT | 24-MAY-18:15 | 0.00 | -1695.42 | 0.00 | 0.00 | 141.82 | 230.46 | 547.42 | 505.29 | 0.00 | 340.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -69.86 |
F9 S1 APARTMENT | 23-APR-16:00 | 0.00 | -2377.16 | 0.00 | 0.00 | 48.90 | 100.83 | 470.89 | 1030.80 | 0.00 | 977.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -251.85 |
F9 S2 APARTMENT | 23-APR-16:00 | 0.00 | -2366.12 | 0.00 | 0.00 | 48.90 | 100.83 | 470.89 | 1030.96 | 0.00 | 977.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -263.05 |
T SW APARTMENT | 01-SEP-15:30 | 0.00 | -4052.49 | 0.00 | 0.00 | 48.91 | 100.83 | 470.89 | 3998.28 | 0.00 | 232.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -798.90 |
T NW APARTMENT | 29-JUL-16:30 | 0.00 | -3387.75 | 0.00 | 0.00 | 84.51 | 144.04 | 588.62 | 2764.71 | 0.00 | 92.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -286.95 |
T SE APARTMENT | 25-AUG-12:15 | 0.00 | -3550.89 | 0.00 | 0.00 | 40.76 | 28.81 | 388.49 | 2937.99 | 0.00 | 380.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -225.87 |
T NE APARTMENT | 12-JUL-12:00 | 0.00 | -2602.48 | 0.00 | 0.00 | 40.76 | 28.81 | 406.15 | 1106.97 | 0.00 | 703.22 | 316.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 11-JUL-15:45 | 0.00 | -2018.29 | 0.00 | 0.00 | 48.67 | 100.83 | 470.89 | 474.17 | 0.00 | 375.69 | 548.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 11-JUL-15:45 | 0.00 | -2017.62 | 0.00 | 0.00 | 48.71 | 100.83 | 470.89 | 474.56 | 0.00 | 378.42 | 544.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 24-MAY-13:30 | 0.00 | -3090.92 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 2154.54 | 0.00 | 545.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -61.40 |
T S2 APARTMENT | 24-MAY-13:30 | 0.00 | -3099.65 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 2154.33 | 0.00 | 545.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -52.47 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 18-JUN-13:45 | 0.00 | -168423.93 | 0.00 | 0.00 | 3219.05 | 9118.54 | 30507.83 | 118799.02 | 0.00 | 51965.53 | 0.00 | 0.00 | 0.00 | 0.00 | -40.10 | -45145.94 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 04-JAN-08:15 | 2680.96 | 0.00 | 0.00 | 0.00 | 73.97 | 43.21 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1445.59 | 0.00 | -734.27 | -1006.77 |
G NW APARTMENT | 04-JAN-08:30 | 2867.15 | 0.00 | 0.00 | 0.00 | 73.97 | 43.21 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1725.74 | 0.00 | -734.46 | -912.62 |
OFFICE | 24-DEC-07:50 | 2794.59 | 0.00 | 0.00 | 0.00 | 0.00 | 379.58 | 128.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1869.74 | 0.00 | -614.14 | -818.98 |
G NE APARTMENT | 04-JAN-08:15 | 2767.70 | 0.00 | 0.00 | 0.00 | 73.97 | 43.21 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1431.86 | 0.00 | -734.27 | -1107.24 |
G N1 APARTMENT | 05-JAN-08:30 | 1912.07 | 0.00 | 0.00 | 0.00 | 73.97 | 43.21 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1083.55 | 0.00 | -304.13 | -1030.06 |
G N2 APARTMENT | 05-JAN-08:30 | 1911.07 | 0.00 | 0.00 | 0.00 | 73.97 | 43.21 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1083.55 | 0.00 | -304.13 | -1029.07 |
G S1 APARTMENT | 04-JAN-08:05 | 1701.76 | 0.00 | 0.00 | 0.00 | 73.97 | 43.21 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -781.93 | 0.00 | -442.89 | -982.61 |
G S2 APARTMENT | 04-JAN-08:05 | 1694.79 | 0.00 | 0.00 | 0.00 | 73.97 | 43.21 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -782.05 | 0.00 | -442.89 | -975.52 |
F2 SW APARTMENT | 04-JAN-06:00 | 2808.34 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1917.77 | 0.00 | -1315.98 | -111.00 |
F2 NW APARTMENT | 04-JAN-12:00 | 3111.45 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1410.65 | 0.00 | -1591.97 | -597.08 |
F2 SE APARTMENT | 04-JAN-06:00 | 2766.88 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1905.99 | 0.00 | -1315.98 | -81.31 |
F2 NE APARTMENT | 04-JAN-06:00 | 2973.71 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1917.28 | 0.00 | -1315.98 | -276.85 |
F2 N1 APARTMENT | 04-JAN-12:00 | 1762.76 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -864.05 | 0.00 | -960.24 | -426.72 |
F2 N2 APARTMENT | 04-JAN-12:00 | 1758.04 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -864.16 | 0.00 | -960.24 | -421.89 |
F2 S1 APARTMENT | 27-JAN-23:55 | 1493.91 | 0.00 | 0.00 | 0.00 | 189.67 | 36.01 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1047.56 | 0.00 | 0.00 | -1013.43 |
F2 S2 APARTMENT | 27-JAN-23:55 | 1483.56 | 0.00 | 0.00 | 0.00 | 189.67 | 36.01 | 341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1047.62 | 0.00 | 0.00 | -1003.02 |
F3 SW APARTMENT | 04-JAN-06:00 | 2958.58 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 9.91 | 0.00 | -1946.54 | 0.00 | -1558.35 | 0.00 |
F3 NW APARTMENT | 04-JAN-12:00 | 3325.52 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1451.14 | 0.00 | -1885.18 | -477.45 |
F3 SE APARTMENT | 04-JAN-06:00 | 2946.05 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 5.29 | 0.00 | -1929.39 | 0.00 | -1558.35 | 0.00 |
F3 NE APARTMENT | 04-JAN-12:00 | 3174.34 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1379.01 | 0.00 | -1885.20 | -398.39 |
F3 N1 APARTMENT | 04-JAN-12:00 | 1850.96 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -889.18 | 0.00 | -1137.10 | -312.93 |
F3 N2 APARTMENT | 04-JAN-12:00 | 1846.30 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -889.29 | 0.00 | -1137.10 | -308.17 |
F3 S1 APARTMENT | 04-JAN-06:00 | 1515.32 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 65.44 | 0.00 | -1177.20 | 0.00 | -939.96 | 0.00 |
F3 S2 APARTMENT | 04-JAN-06:00 | 1514.56 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 66.21 | 0.00 | -1177.22 | 0.00 | -939.96 | 0.00 |
F4 SW APARTMENT | 04-JAN-06:00 | 3129.93 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 40.24 | 0.00 | -1964.39 | 0.00 | -1742.18 | 0.00 |
F4 NW APARTMENT | 04-JAN-12:00 | 3546.21 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1476.41 | 0.00 | -2107.57 | -450.48 |
F4 SE APARTMENT | 04-JAN-06:00 | 3120.47 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 29.69 | 0.00 | -1944.38 | 0.00 | -1742.18 | 0.00 |
F4 NE APARTMENT | 04-JAN-12:00 | 3393.54 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1401.67 | 0.00 | -2107.59 | -372.54 |
F4 N1 APARTMENT | 04-JAN-12:00 | 1973.96 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -904.80 | 0.00 | -1271.25 | -286.17 |
F4 N2 APARTMENT | 04-JAN-12:00 | 1969.28 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -904.91 | 0.00 | -1271.25 | -281.38 |
F4 S1 APARTMENT | 06-JAN-09:25 | 1653.38 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 394.37 | 1135.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -123.99 | -3135.23 |
F4 S2 APARTMENT | 04-JAN-06:00 | 1601.62 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 99.59 | 0.00 | -1186.78 | 0.00 | -1050.84 | 0.00 |
M SW APARTMENT | 04-JAN-06:00 | 3263.29 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 71.61 | 0.00 | -1977.58 | 0.00 | -1893.72 | 0.00 |
M NW APARTMENT | 04-JAN-12:00 | 3715.87 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1495.77 | 0.00 | -2290.91 | -417.44 |
M SE APARTMENT | 04-JAN-06:00 | 3252.96 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 60.72 | 0.00 | -1956.36 | 0.00 | -1893.72 | 0.00 |
M NE APARTMENT | 04-JAN-12:00 | 3562.36 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1419.20 | 0.00 | -2290.93 | -340.49 |
M N1 APARTMENT | 04-JAN-12:00 | 2065.50 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -916.78 | 0.00 | -1381.83 | -255.14 |
M N2 APARTMENT | 04-JAN-12:00 | 2060.80 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -916.90 | 0.00 | -1381.83 | -250.33 |
M S1 APARTMENT | 04-JAN-06:00 | 1670.41 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 129.70 | 0.00 | -1194.27 | 0.00 | -1142.25 | 0.00 |
M S2 APARTMENT | 04-JAN-06:00 | 1670.26 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 129.86 | 0.00 | -1194.27 | 0.00 | -1142.25 | 0.00 |
F6 SW APARTMENT | 04-JAN-06:00 | 3440.69 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 33.98 | 0.00 | -1986.73 | 0.00 | -2024.33 | 0.00 |
F6 NW APARTMENT | 04-JAN-12:00 | 3921.70 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1509.31 | 0.00 | -2448.93 | -451.72 |
F6 SE APARTMENT | 04-JAN-06:00 | 3428.98 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 23.06 | 0.00 | -1964.12 | 0.00 | -2024.33 | 0.00 |
F6 NE APARTMENT | 04-JAN-12:00 | 3766.76 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1431.32 | 0.00 | -2448.95 | -374.74 |
F6 N1 APARTMENT | 04-JAN-12:00 | 2201.89 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -925.01 | 0.00 | -1477.14 | -287.99 |
F6 N2 APARTMENT | 04-JAN-12:00 | 2197.15 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -925.13 | 0.00 | -1477.14 | -283.14 |
F6 S1 APARTMENT | 04-JAN-06:00 | 1789.83 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 93.70 | 0.00 | -1198.90 | 0.00 | -1221.02 | 0.00 |
F6 S2 APARTMENT | 04-JAN-06:00 | 1789.65 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 93.88 | 0.00 | -1198.91 | 0.00 | -1221.02 | 0.00 |
F7 SW APARTMENT | 04-JAN-06:00 | 3582.94 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 15.62 | 0.00 | -1994.90 | 0.00 | -2140.07 | 0.00 |
F7 NW APARTMENT | 04-JAN-12:00 | 4087.06 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1521.07 | 0.00 | -2588.95 | -465.30 |
F7 SE APARTMENT | 04-JAN-06:00 | 3570.18 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 4.64 | 0.00 | -1971.15 | 0.00 | -2140.07 | 0.00 |
F7 NE APARTMENT | 04-JAN-12:00 | 3931.20 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1441.96 | 0.00 | -2588.97 | -388.52 |
F7 N1 APARTMENT | 04-JAN-12:00 | 2307.59 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -932.18 | 0.00 | -1561.61 | -302.07 |
F7 N2 APARTMENT | 04-JAN-12:00 | 2302.82 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -932.29 | 0.00 | -1561.61 | -297.18 |
F7 S1 APARTMENT | 01-NOV-10:40 | 1970.91 | 0.00 | 0.00 | 0.00 | 45.44 | 28.81 | 412.03 | 377.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1880.61 | -954.27 |
F7 S2 APARTMENT | 01-NOV-10:40 | 1960.72 | 0.00 | 0.00 | 0.00 | 45.42 | 28.81 | 412.03 | 377.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1880.97 | -943.59 |
F8 SW APARTMENT | 04-JAN-06:00 | 3723.98 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2001.58 | 0.00 | -2244.61 | -14.19 |
F8 NW APARTMENT | 04-JAN-12:00 | 4246.72 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1530.81 | 0.00 | -2715.44 | -488.73 |
F8 SE APARTMENT | 04-JAN-06:00 | 3710.44 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1976.91 | 0.00 | -2244.61 | -25.32 |
F8 NE APARTMENT | 04-JAN-12:00 | 4089.97 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1450.79 | 0.00 | -2715.46 | -411.98 |
F8 N1 APARTMENT | 04-JAN-12:00 | 2413.17 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -936.89 | 0.00 | -1637.90 | -326.64 |
F8 N2 APARTMENT | 04-JAN-12:00 | 2408.38 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -937.00 | 0.00 | -1637.90 | -321.74 |
F8 S1 APARTMENT | 01-NOV-10:40 | 2205.90 | 0.00 | 0.00 | 0.00 | 45.61 | 28.81 | 412.03 | 376.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1953.29 | -1115.86 |
F8 S2 APARTMENT | 01-NOV-10:40 | 2208.52 | 0.00 | 0.00 | 0.00 | 45.59 | 28.81 | 412.03 | 376.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1953.34 | -1118.29 |
F9 SW APARTMENT | 04-JAN-06:00 | 4013.40 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2002.87 | 0.00 | -2340.37 | -206.56 |
F9 NW APARTMENT | 04-JAN-12:00 | 4538.48 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1532.87 | 0.00 | -2831.30 | -662.58 |
F9 SE APARTMENT | 04-JAN-06:00 | 3999.31 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1977.47 | 0.00 | -2340.37 | -217.87 |
F9 NE APARTMENT | 04-JAN-12:00 | 4375.28 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1452.96 | 0.00 | -2831.32 | -579.25 |
F9 N1 APARTMENT | 04-JAN-12:00 | 2647.07 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -938.95 | 0.00 | -1707.78 | -488.60 |
F9 N2 APARTMENT | 04-JAN-12:00 | 2642.02 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -939.06 | 0.00 | -1707.78 | -483.43 |
F9 S1 APARTMENT | 04-JAN-06:00 | 2229.89 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1206.17 | 0.00 | -1411.65 | -148.47 |
F9 S2 APARTMENT | 04-JAN-06:00 | 2229.76 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1206.18 | 0.00 | -1411.65 | -148.33 |
T SW APARTMENT | 04-JAN-06:00 | 5112.87 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1965.06 | 0.00 | -2428.83 | -1255.38 |
T NW APARTMENT | 04-JAN-12:00 | 5294.83 | 0.00 | 0.00 | 0.00 | 47.42 | 28.81 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1505.20 | 0.00 | -2938.32 | -1339.58 |
T SE APARTMENT | 04-JAN-06:00 | 5094.74 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1939.67 | 0.00 | -2428.83 | -1262.64 |
T NE APARTMENT | 04-JAN-06:00 | 5185.30 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1972.38 | 0.00 | -2428.83 | -1320.49 |
T N1 APARTMENT | 04-JAN-06:00 | 3435.45 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1217.29 | 0.00 | -1465.07 | -1289.49 |
T N2 APARTMENT | 04-JAN-06:00 | 3435.26 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1217.30 | 0.00 | -1465.07 | -1289.30 |
T S1 APARTMENT | 04-JAN-06:00 | 3331.47 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1183.96 | 0.00 | -1465.06 | -1218.85 |
T S2 APARTMENT | 04-JAN-06:00 | 3331.22 | 0.00 | 0.00 | 0.00 | 189.67 | 93.62 | 253.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1183.97 | 0.00 | -1465.06 | -1218.59 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 04-JAN-06:00 | 220679.06 | 0.00 | 0.00 | 0.00 | 14983.93 | 14239.10 | 20328.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -129099.38 | 0.00 | -122425.49 | -18706.04 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:12
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:12
Sec1.1A-General InformationData | |
Weather File | International Falls Intl Ap MN USA TMY3 WMO#=727470 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 7836.48 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.50 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F2 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F3 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F4 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F6 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F7 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F8 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F9 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 7836.48 | 7059.89 | 776.58 |
Data | |
Number of hours heating loads not met | 117.00 |
Number of hours cooling loads not met | 99.25 |
Number of hours not met | 216.25 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 416.41 | 25049.15 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 168.30 | 10720.10 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 415.05 | 79904.96 | 1570.73 | 265391.88 | 0.00 | 0.00 |
Space Cooling | 231.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 49.47 | 1587.47 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 9.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 589.61 | 18696.25 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 0.00 | 0.00 | 1375.77 | 92291.40 | 0.00 | 0.00 |
Receptacle Equipment | 1131.09 | 49704.83 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 3032.08 | 2946.50 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 1131.09 | 3032.08 |
Natural Gas | 0.00 | 2946.50 |
Additional | 0.00 | 0.00 |
Total | 1131.09 | 5978.59 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 53.14 |
Space Heating | 52.96 |
Space Cooling | 29.55 |
Fans-Interior | 75.24 |
Service Water Heating | 0.00 |
Receptacle Equipment | 144.34 |
Miscellaneous | 31.69 |
Subtotal | 386.92 |
Natural Gas [MJ/m2] | |
Space Heating | 200.44 |
Service Water Heating | 175.56 |
Miscellaneous | 0.00 |
Subtotal | 376.00 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 6.97 |
Space Heating | 33.22 |
Space Cooling | 3.87 |
Fans-Interior | 9.86 |
Service Water Heating | 23.01 |
Receptacle Equipment | 18.92 |
Miscellaneous | 4.15 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:12
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.209419 |
G NW APARTMENT DIRECT AIR | 0.186430 |
OFFICE DIRECT AIR | 0.296517 |
G NE APARTMENT DIRECT AIR | 0.157158 |
G N1 APARTMENT DIRECT AIR | 0.108511 |
G N2 APARTMENT DIRECT AIR | 0.108518 |
G S1 APARTMENT DIRECT AIR | 0.139654 |
G S2 APARTMENT DIRECT AIR | 0.145042 |
F2 SW APARTMENT DIRECT AIR | 0.280855 |
F2 NW APARTMENT DIRECT AIR | 0.248577 |
F2 SE APARTMENT DIRECT AIR | 0.273972 |
F2 NE APARTMENT DIRECT AIR | 0.185831 |
F2 N1 APARTMENT DIRECT AIR | 0.132945 |
F2 N2 APARTMENT DIRECT AIR | 0.131420 |
F2 S1 APARTMENT DIRECT AIR | 0.191216 |
F2 S2 APARTMENT DIRECT AIR | 0.193379 |
F3 SW APARTMENT DIRECT AIR | 0.282383 |
F3 NW APARTMENT DIRECT AIR | 0.251635 |
F3 SE APARTMENT DIRECT AIR | 0.259973 |
F3 NE APARTMENT DIRECT AIR | 0.189861 |
F3 N1 APARTMENT DIRECT AIR | 0.137466 |
F3 N2 APARTMENT DIRECT AIR | 0.135954 |
F3 S1 APARTMENT DIRECT AIR | 0.195308 |
F3 S2 APARTMENT DIRECT AIR | 0.196474 |
F4 SW APARTMENT DIRECT AIR | 0.282905 |
F4 NW APARTMENT DIRECT AIR | 0.252513 |
F4 SE APARTMENT DIRECT AIR | 0.259290 |
F4 NE APARTMENT DIRECT AIR | 0.190659 |
F4 N1 APARTMENT DIRECT AIR | 0.138841 |
F4 N2 APARTMENT DIRECT AIR | 0.137335 |
F4 S1 APARTMENT DIRECT AIR | 0.196368 |
F4 S2 APARTMENT DIRECT AIR | 0.197386 |
M SW APARTMENT DIRECT AIR | 0.285533 |
M NW APARTMENT DIRECT AIR | 0.255443 |
M SE APARTMENT DIRECT AIR | 0.262066 |
M NE APARTMENT DIRECT AIR | 0.193466 |
M N1 APARTMENT DIRECT AIR | 0.141995 |
M N2 APARTMENT DIRECT AIR | 0.140493 |
M S1 APARTMENT DIRECT AIR | 0.199303 |
M S2 APARTMENT DIRECT AIR | 0.200300 |
F6 SW APARTMENT DIRECT AIR | 0.281638 |
F6 NW APARTMENT DIRECT AIR | 0.251629 |
F6 SE APARTMENT DIRECT AIR | 0.258460 |
F6 NE APARTMENT DIRECT AIR | 0.189678 |
F6 N1 APARTMENT DIRECT AIR | 0.138682 |
F6 N2 APARTMENT DIRECT AIR | 0.137192 |
F6 S1 APARTMENT DIRECT AIR | 0.195701 |
F6 S2 APARTMENT DIRECT AIR | 0.196697 |
F7 SW APARTMENT DIRECT AIR | 0.280165 |
F7 NW APARTMENT DIRECT AIR | 0.250306 |
F7 SE APARTMENT DIRECT AIR | 0.257243 |
F7 NE APARTMENT DIRECT AIR | 0.188326 |
F7 N1 APARTMENT DIRECT AIR | 0.137687 |
F7 N2 APARTMENT DIRECT AIR | 0.136224 |
F7 S1 APARTMENT DIRECT AIR | 0.194465 |
F7 S2 APARTMENT DIRECT AIR | 0.195450 |
F8 SW APARTMENT DIRECT AIR | 0.280003 |
F8 NW APARTMENT DIRECT AIR | 0.250292 |
F8 SE APARTMENT DIRECT AIR | 0.257223 |
F8 NE APARTMENT DIRECT AIR | 0.188198 |
F8 N1 APARTMENT DIRECT AIR | 0.137989 |
F8 N2 APARTMENT DIRECT AIR | 0.136544 |
F8 S1 APARTMENT DIRECT AIR | 0.194445 |
F8 S2 APARTMENT DIRECT AIR | 0.195420 |
F9 SW APARTMENT DIRECT AIR | 0.288359 |
F9 NW APARTMENT DIRECT AIR | 0.258315 |
F9 SE APARTMENT DIRECT AIR | 0.262837 |
F9 NE APARTMENT DIRECT AIR | 0.190382 |
F9 N1 APARTMENT DIRECT AIR | 0.145049 |
F9 N2 APARTMENT DIRECT AIR | 0.143571 |
F9 S1 APARTMENT DIRECT AIR | 0.199190 |
F9 S2 APARTMENT DIRECT AIR | 0.200198 |
T SW APARTMENT DIRECT AIR | 0.353571 |
T NW APARTMENT DIRECT AIR | 0.306538 |
T SE APARTMENT DIRECT AIR | 0.322838 |
T NE APARTMENT DIRECT AIR | 0.231503 |
T N1 APARTMENT DIRECT AIR | 0.172777 |
T N2 APARTMENT DIRECT AIR | 0.172590 |
T S1 APARTMENT DIRECT AIR | 0.270354 |
T S2 APARTMENT DIRECT AIR | 0.271350 |
Maximum Flow Rate [m3/s] | |
AIRLOOP G SW MAIN BRANCH | 0.209419 |
AIRLOOP G NW MAIN BRANCH | 0.186430 |
AIRLOOP OFFICE MAIN BRANCH | 0.296517 |
AIRLOOP G NE MAIN BRANCH | 0.157158 |
AIRLOOP G N1 MAIN BRANCH | 0.108511 |
AIRLOOP G N2 MAIN BRANCH | 0.108518 |
AIRLOOP G S1 MAIN BRANCH | 0.139654 |
AIRLOOP G S2 MAIN BRANCH | 0.145042 |
AIRLOOP F2 SW MAIN BRANCH | 0.280855 |
AIRLOOP F2 NW MAIN BRANCH | 0.248577 |
AIRLOOP F2 SE MAIN BRANCH | 0.273972 |
AIRLOOP F2 NE MAIN BRANCH | 0.185831 |
AIRLOOP F2 N1 MAIN BRANCH | 0.132945 |
AIRLOOP F2 N2 MAIN BRANCH | 0.131420 |
AIRLOOP F2 S1 MAIN BRANCH | 0.191216 |
AIRLOOP F2 S2 MAIN BRANCH | 0.193379 |
AIRLOOP F3 SW MAIN BRANCH | 0.282383 |
AIRLOOP F3 NW MAIN BRANCH | 0.251635 |
AIRLOOP F3 SE MAIN BRANCH | 0.259973 |
AIRLOOP F3 NE MAIN BRANCH | 0.189861 |
AIRLOOP F3 N1 MAIN BRANCH | 0.137466 |
AIRLOOP F3 N2 MAIN BRANCH | 0.135954 |
AIRLOOP F3 S1 MAIN BRANCH | 0.195308 |
AIRLOOP F3 S2 MAIN BRANCH | 0.196474 |
AIRLOOP F4 SW MAIN BRANCH | 0.282905 |
AIRLOOP F4 NW MAIN BRANCH | 0.252513 |
AIRLOOP F4 SE MAIN BRANCH | 0.259290 |
AIRLOOP F4 NE MAIN BRANCH | 0.190659 |
AIRLOOP F4 N1 MAIN BRANCH | 0.138841 |
AIRLOOP F4 N2 MAIN BRANCH | 0.137335 |
AIRLOOP F4 S1 MAIN BRANCH | 0.196368 |
AIRLOOP F4 S2 MAIN BRANCH | 0.197386 |
AIRLOOP M SW MAIN BRANCH | 0.285533 |
AIRLOOP M NW MAIN BRANCH | 0.255443 |
AIRLOOP M SE MAIN BRANCH | 0.262066 |
AIRLOOP M NE MAIN BRANCH | 0.193466 |
AIRLOOP M N1 MAIN BRANCH | 0.141995 |
AIRLOOP M N2 MAIN BRANCH | 0.140493 |
AIRLOOP M S1 MAIN BRANCH | 0.199303 |
AIRLOOP M S2 MAIN BRANCH | 0.200300 |
AIRLOOP F6 SW MAIN BRANCH | 0.281638 |
AIRLOOP F6 NW MAIN BRANCH | 0.251629 |
AIRLOOP F6 SE MAIN BRANCH | 0.258460 |
AIRLOOP F6 NE MAIN BRANCH | 0.189678 |
AIRLOOP F6 N1 MAIN BRANCH | 0.138682 |
AIRLOOP F6 N2 MAIN BRANCH | 0.137192 |
AIRLOOP F6 S1 MAIN BRANCH | 0.195701 |
AIRLOOP F6 S2 MAIN BRANCH | 0.196697 |
AIRLOOP F7 SW MAIN BRANCH | 0.280165 |
AIRLOOP F7 NW MAIN BRANCH | 0.250306 |
AIRLOOP F7 SE MAIN BRANCH | 0.257243 |
AIRLOOP F7 NE MAIN BRANCH | 0.188326 |
AIRLOOP F7 N1 MAIN BRANCH | 0.137687 |
AIRLOOP F7 N2 MAIN BRANCH | 0.136224 |
AIRLOOP F7 S1 MAIN BRANCH | 0.194465 |
AIRLOOP F7 S2 MAIN BRANCH | 0.195450 |
AIRLOOP F8 SW MAIN BRANCH | 0.280003 |
AIRLOOP F8 NW MAIN BRANCH | 0.250292 |
AIRLOOP F8 SE MAIN BRANCH | 0.257223 |
AIRLOOP F8 NE MAIN BRANCH | 0.188198 |
AIRLOOP F8 N1 MAIN BRANCH | 0.137989 |
AIRLOOP F8 N2 MAIN BRANCH | 0.136544 |
AIRLOOP F8 S1 MAIN BRANCH | 0.194445 |
AIRLOOP F8 S2 MAIN BRANCH | 0.195420 |
AIRLOOP F9 SW MAIN BRANCH | 0.288359 |
AIRLOOP F9 NW MAIN BRANCH | 0.258315 |
AIRLOOP F9 SE MAIN BRANCH | 0.262837 |
AIRLOOP F9 NE MAIN BRANCH | 0.190382 |
AIRLOOP F9 N1 MAIN BRANCH | 0.145049 |
AIRLOOP F9 N2 MAIN BRANCH | 0.143571 |
AIRLOOP F9 S1 MAIN BRANCH | 0.199190 |
AIRLOOP F9 S2 MAIN BRANCH | 0.200198 |
AIRLOOP T SW MAIN BRANCH | 0.353571 |
AIRLOOP T NW MAIN BRANCH | 0.306538 |
AIRLOOP T SE MAIN BRANCH | 0.322838 |
AIRLOOP T NE MAIN BRANCH | 0.231503 |
AIRLOOP T N1 MAIN BRANCH | 0.172777 |
AIRLOOP T N2 MAIN BRANCH | 0.172590 |
AIRLOOP T S1 MAIN BRANCH | 0.270354 |
AIRLOOP T S2 MAIN BRANCH | 0.271350 |
Design Supply Air Flow Rate [m3/s] | |
AIRLOOP G SW | 0.209419 |
AIRLOOP G NW | 0.186430 |
AIRLOOP OFFICE | 0.296517 |
AIRLOOP G NE | 0.157158 |
AIRLOOP G N1 | 0.108511 |
AIRLOOP G N2 | 0.108518 |
AIRLOOP G S1 | 0.139654 |
AIRLOOP G S2 | 0.145042 |
AIRLOOP F2 SW | 0.280855 |
AIRLOOP F2 NW | 0.248577 |
AIRLOOP F2 SE | 0.273972 |
AIRLOOP F2 NE | 0.185831 |
AIRLOOP F2 N1 | 0.132945 |
AIRLOOP F2 N2 | 0.131420 |
AIRLOOP F2 S1 | 0.191216 |
AIRLOOP F2 S2 | 0.193379 |
AIRLOOP F3 SW | 0.282383 |
AIRLOOP F3 NW | 0.251635 |
AIRLOOP F3 SE | 0.259973 |
AIRLOOP F3 NE | 0.189861 |
AIRLOOP F3 N1 | 0.137466 |
AIRLOOP F3 N2 | 0.135954 |
AIRLOOP F3 S1 | 0.195308 |
AIRLOOP F3 S2 | 0.196474 |
AIRLOOP F4 SW | 0.282905 |
AIRLOOP F4 NW | 0.252513 |
AIRLOOP F4 SE | 0.259290 |
AIRLOOP F4 NE | 0.190659 |
AIRLOOP F4 N1 | 0.138841 |
AIRLOOP F4 N2 | 0.137335 |
AIRLOOP F4 S1 | 0.196368 |
AIRLOOP F4 S2 | 0.197386 |
AIRLOOP M SW | 0.285533 |
AIRLOOP M NW | 0.255443 |
AIRLOOP M SE | 0.262066 |
AIRLOOP M NE | 0.193466 |
AIRLOOP M N1 | 0.141995 |
AIRLOOP M N2 | 0.140493 |
AIRLOOP M S1 | 0.199303 |
AIRLOOP M S2 | 0.200300 |
AIRLOOP F6 SW | 0.281638 |
AIRLOOP F6 NW | 0.251629 |
AIRLOOP F6 SE | 0.258460 |
AIRLOOP F6 NE | 0.189678 |
AIRLOOP F6 N1 | 0.138682 |
AIRLOOP F6 N2 | 0.137192 |
AIRLOOP F6 S1 | 0.195701 |
AIRLOOP F6 S2 | 0.196697 |
AIRLOOP F7 SW | 0.280165 |
AIRLOOP F7 NW | 0.250306 |
AIRLOOP F7 SE | 0.257243 |
AIRLOOP F7 NE | 0.188326 |
AIRLOOP F7 N1 | 0.137687 |
AIRLOOP F7 N2 | 0.136224 |
AIRLOOP F7 S1 | 0.194465 |
AIRLOOP F7 S2 | 0.195450 |
AIRLOOP F8 SW | 0.280003 |
AIRLOOP F8 NW | 0.250292 |
AIRLOOP F8 SE | 0.257223 |
AIRLOOP F8 NE | 0.188198 |
AIRLOOP F8 N1 | 0.137989 |
AIRLOOP F8 N2 | 0.136544 |
AIRLOOP F8 S1 | 0.194445 |
AIRLOOP F8 S2 | 0.195420 |
AIRLOOP F9 SW | 0.288359 |
AIRLOOP F9 NW | 0.258315 |
AIRLOOP F9 SE | 0.262837 |
AIRLOOP F9 NE | 0.190382 |
AIRLOOP F9 N1 | 0.145049 |
AIRLOOP F9 N2 | 0.143571 |
AIRLOOP F9 S1 | 0.199190 |
AIRLOOP F9 S2 | 0.200198 |
AIRLOOP T SW | 0.353571 |
AIRLOOP T NW | 0.306538 |
AIRLOOP T SE | 0.322838 |
AIRLOOP T NE | 0.231503 |
AIRLOOP T N1 | 0.172777 |
AIRLOOP T N2 | 0.172590 |
AIRLOOP T S1 | 0.270354 |
AIRLOOP T S2 | 0.271350 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
AIRLOOP G SW OA CONTROLLER | 0.209419 | 0.025952 |
AIRLOOP G NW OA CONTROLLER | 0.186430 | 0.025952 |
AIRLOOP OFFICE OA CONTROLLER | 0.296517 | 0.038103 |
AIRLOOP G NE OA CONTROLLER | 0.157158 | 0.025952 |
AIRLOOP G N1 OA CONTROLLER | 0.108511 | 0.025952 |
AIRLOOP G N2 OA CONTROLLER | 0.108518 | 0.025952 |
AIRLOOP G S1 OA CONTROLLER | 0.139654 | 0.025952 |
AIRLOOP G S2 OA CONTROLLER | 0.145042 | 0.025952 |
AIRLOOP F2 SW OA CONTROLLER | 0.280855 | 0.025952 |
AIRLOOP F2 NW OA CONTROLLER | 0.248577 | 0.025952 |
AIRLOOP F2 SE OA CONTROLLER | 0.273972 | 0.025952 |
AIRLOOP F2 NE OA CONTROLLER | 0.185831 | 0.025952 |
AIRLOOP F2 N1 OA CONTROLLER | 0.132945 | 0.025952 |
AIRLOOP F2 N2 OA CONTROLLER | 0.131420 | 0.025952 |
AIRLOOP F2 S1 OA CONTROLLER | 0.191216 | 0.025952 |
AIRLOOP F2 S2 OA CONTROLLER | 0.193379 | 0.025952 |
AIRLOOP F3 SW OA CONTROLLER | 0.282383 | 0.025952 |
AIRLOOP F3 NW OA CONTROLLER | 0.251635 | 0.025952 |
AIRLOOP F3 SE OA CONTROLLER | 0.259973 | 0.025952 |
AIRLOOP F3 NE OA CONTROLLER | 0.189861 | 0.025952 |
AIRLOOP F3 N1 OA CONTROLLER | 0.137466 | 0.025952 |
AIRLOOP F3 N2 OA CONTROLLER | 0.135954 | 0.025952 |
AIRLOOP F3 S1 OA CONTROLLER | 0.195308 | 0.025952 |
AIRLOOP F3 S2 OA CONTROLLER | 0.196474 | 0.025952 |
AIRLOOP F4 SW OA CONTROLLER | 0.282905 | 0.025952 |
AIRLOOP F4 NW OA CONTROLLER | 0.252513 | 0.025952 |
AIRLOOP F4 SE OA CONTROLLER | 0.259290 | 0.025952 |
AIRLOOP F4 NE OA CONTROLLER | 0.190659 | 0.025952 |
AIRLOOP F4 N1 OA CONTROLLER | 0.138841 | 0.025952 |
AIRLOOP F4 N2 OA CONTROLLER | 0.137335 | 0.025952 |
AIRLOOP F4 S1 OA CONTROLLER | 0.196368 | 0.025952 |
AIRLOOP F4 S2 OA CONTROLLER | 0.197386 | 0.025952 |
AIRLOOP M SW OA CONTROLLER | 0.285533 | 0.025952 |
AIRLOOP M NW OA CONTROLLER | 0.255443 | 0.025952 |
AIRLOOP M SE OA CONTROLLER | 0.262066 | 0.025952 |
AIRLOOP M NE OA CONTROLLER | 0.193466 | 0.025952 |
AIRLOOP M N1 OA CONTROLLER | 0.141995 | 0.025952 |
AIRLOOP M N2 OA CONTROLLER | 0.140493 | 0.025952 |
AIRLOOP M S1 OA CONTROLLER | 0.199303 | 0.025952 |
AIRLOOP M S2 OA CONTROLLER | 0.200300 | 0.025952 |
AIRLOOP F6 SW OA CONTROLLER | 0.281638 | 0.025952 |
AIRLOOP F6 NW OA CONTROLLER | 0.251629 | 0.025952 |
AIRLOOP F6 SE OA CONTROLLER | 0.258460 | 0.025952 |
AIRLOOP F6 NE OA CONTROLLER | 0.189678 | 0.025952 |
AIRLOOP F6 N1 OA CONTROLLER | 0.138682 | 0.025952 |
AIRLOOP F6 N2 OA CONTROLLER | 0.137192 | 0.025952 |
AIRLOOP F6 S1 OA CONTROLLER | 0.195701 | 0.025952 |
AIRLOOP F6 S2 OA CONTROLLER | 0.196697 | 0.025952 |
AIRLOOP F7 SW OA CONTROLLER | 0.280165 | 0.025952 |
AIRLOOP F7 NW OA CONTROLLER | 0.250306 | 0.025952 |
AIRLOOP F7 SE OA CONTROLLER | 0.257243 | 0.025952 |
AIRLOOP F7 NE OA CONTROLLER | 0.188326 | 0.025952 |
AIRLOOP F7 N1 OA CONTROLLER | 0.137687 | 0.025952 |
AIRLOOP F7 N2 OA CONTROLLER | 0.136224 | 0.025952 |
AIRLOOP F7 S1 OA CONTROLLER | 0.194465 | 0.025952 |
AIRLOOP F7 S2 OA CONTROLLER | 0.195450 | 0.025952 |
AIRLOOP F8 SW OA CONTROLLER | 0.280003 | 0.025952 |
AIRLOOP F8 NW OA CONTROLLER | 0.250292 | 0.025952 |
AIRLOOP F8 SE OA CONTROLLER | 0.257223 | 0.025952 |
AIRLOOP F8 NE OA CONTROLLER | 0.188198 | 0.025952 |
AIRLOOP F8 N1 OA CONTROLLER | 0.137989 | 0.025952 |
AIRLOOP F8 N2 OA CONTROLLER | 0.136544 | 0.025952 |
AIRLOOP F8 S1 OA CONTROLLER | 0.194445 | 0.025952 |
AIRLOOP F8 S2 OA CONTROLLER | 0.195420 | 0.025952 |
AIRLOOP F9 SW OA CONTROLLER | 0.288359 | 0.025952 |
AIRLOOP F9 NW OA CONTROLLER | 0.258315 | 0.025952 |
AIRLOOP F9 SE OA CONTROLLER | 0.262837 | 0.025952 |
AIRLOOP F9 NE OA CONTROLLER | 0.190382 | 0.025952 |
AIRLOOP F9 N1 OA CONTROLLER | 0.145049 | 0.025952 |
AIRLOOP F9 N2 OA CONTROLLER | 0.143571 | 0.025952 |
AIRLOOP F9 S1 OA CONTROLLER | 0.199190 | 0.025952 |
AIRLOOP F9 S2 OA CONTROLLER | 0.200198 | 0.025952 |
AIRLOOP T SW OA CONTROLLER | 0.353571 | 0.025952 |
AIRLOOP T NW OA CONTROLLER | 0.306538 | 0.025952 |
AIRLOOP T SE OA CONTROLLER | 0.322838 | 0.025952 |
AIRLOOP T NE OA CONTROLLER | 0.231503 | 0.025952 |
AIRLOOP T N1 OA CONTROLLER | 0.172777 | 0.025952 |
AIRLOOP T N2 OA CONTROLLER | 0.172590 | 0.025952 |
AIRLOOP T S1 OA CONTROLLER | 0.270354 | 0.025952 |
AIRLOOP T S2 OA CONTROLLER | 0.271350 | 0.025952 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity [W] | Rated Sensible Cooling Capacity [W] | Rated Water Flow Rate [m3/s] | |
HEAT PUMP COOLING MODE AIRLOOP G SW | 0.209419 | 3451.84 | 2314.73 | 0.000075 |
HEAT PUMP COOLING MODE AIRLOOP G NW | 0.186430 | 3086.52 | 2053.24 | 0.000067 |
HEAT PUMP COOLING MODE AIRLOOP OFFICE | 0.296517 | 4870.99 | 3279.95 | 0.000106 |
HEAT PUMP COOLING MODE AIRLOOP G NE | 0.157158 | 2744.85 | 1770.62 | 0.000060 |
HEAT PUMP COOLING MODE AIRLOOP G N1 | 0.108511 | 2010.15 | 1254.09 | 0.000044 |
HEAT PUMP COOLING MODE AIRLOOP G N2 | 0.108518 | 2019.21 | 1257.04 | 0.000044 |
HEAT PUMP COOLING MODE AIRLOOP G S1 | 0.139654 | 2474.30 | 1604.26 | 0.000054 |
HEAT PUMP COOLING MODE AIRLOOP G S2 | 0.145042 | 2548.46 | 1659.05 | 0.000056 |
HEAT PUMP COOLING MODE AIRLOOP F2 SW | 0.280855 | 4445.64 | 3035.49 | 0.000097 |
HEAT PUMP COOLING MODE AIRLOOP F2 NW | 0.248577 | 3987.51 | 2698.18 | 0.000087 |
HEAT PUMP COOLING MODE AIRLOOP F2 SE | 0.273972 | 4402.78 | 2993.30 | 0.000096 |
HEAT PUMP COOLING MODE AIRLOOP F2 NE | 0.185831 | 3082.89 | 2043.66 | 0.000067 |
HEAT PUMP COOLING MODE AIRLOOP F2 N1 | 0.132945 | 2303.16 | 1486.91 | 0.000050 |
HEAT PUMP COOLING MODE AIRLOOP F2 N2 | 0.131420 | 2281.65 | 1471.32 | 0.000050 |
HEAT PUMP COOLING MODE AIRLOOP F2 S1 | 0.191216 | 3214.86 | 2138.50 | 0.000070 |
HEAT PUMP COOLING MODE AIRLOOP F2 S2 | 0.193379 | 3240.92 | 2158.68 | 0.000071 |
HEAT PUMP COOLING MODE AIRLOOP F3 SW | 0.282383 | 4493.56 | 3058.23 | 0.000098 |
HEAT PUMP COOLING MODE AIRLOOP F3 NW | 0.251635 | 4055.97 | 2736.45 | 0.000089 |
HEAT PUMP COOLING MODE AIRLOOP F3 SE | 0.259973 | 4236.71 | 2857.76 | 0.000093 |
HEAT PUMP COOLING MODE AIRLOOP F3 NE | 0.189861 | 3163.11 | 2091.53 | 0.000069 |
HEAT PUMP COOLING MODE AIRLOOP F3 N1 | 0.137466 | 2380.30 | 1537.02 | 0.000052 |
HEAT PUMP COOLING MODE AIRLOOP F3 N2 | 0.135954 | 2358.96 | 1521.56 | 0.000052 |
HEAT PUMP COOLING MODE AIRLOOP F3 S1 | 0.195308 | 3283.11 | 2182.62 | 0.000072 |
HEAT PUMP COOLING MODE AIRLOOP F3 S2 | 0.196474 | 3299.11 | 2194.48 | 0.000072 |
HEAT PUMP COOLING MODE AIRLOOP F4 SW | 0.282905 | 4520.85 | 3068.94 | 0.000099 |
HEAT PUMP COOLING MODE AIRLOOP F4 NW | 0.252513 | 4087.71 | 2750.73 | 0.000089 |
HEAT PUMP COOLING MODE AIRLOOP F4 SE | 0.259290 | 4246.99 | 2856.14 | 0.000093 |
HEAT PUMP COOLING MODE AIRLOOP F4 NE | 0.190659 | 3192.47 | 2104.79 | 0.000070 |
HEAT PUMP COOLING MODE AIRLOOP F4 N1 | 0.138841 | 2409.90 | 1554.06 | 0.000053 |
HEAT PUMP COOLING MODE AIRLOOP F4 N2 | 0.137335 | 2388.59 | 1538.65 | 0.000052 |
HEAT PUMP COOLING MODE AIRLOOP F4 S1 | 0.196368 | 3309.40 | 2196.63 | 0.000072 |
HEAT PUMP COOLING MODE AIRLOOP F4 S2 | 0.197386 | 3323.39 | 2207.00 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP M SW | 0.285533 | 4573.47 | 3100.13 | 0.000100 |
HEAT PUMP COOLING MODE AIRLOOP M NW | 0.255443 | 4144.18 | 2784.95 | 0.000091 |
HEAT PUMP COOLING MODE AIRLOOP M SE | 0.262066 | 4301.34 | 2888.79 | 0.000094 |
HEAT PUMP COOLING MODE AIRLOOP M NE | 0.193466 | 3246.30 | 2137.57 | 0.000071 |
HEAT PUMP COOLING MODE AIRLOOP M N1 | 0.141995 | 2462.66 | 1588.71 | 0.000054 |
HEAT PUMP COOLING MODE AIRLOOP M N2 | 0.140493 | 2441.40 | 1573.34 | 0.000053 |
HEAT PUMP COOLING MODE AIRLOOP M S1 | 0.199303 | 3359.48 | 2229.19 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP M S2 | 0.200300 | 3373.17 | 2239.33 | 0.000074 |
HEAT PUMP COOLING MODE AIRLOOP F6 SW | 0.281638 | 4533.54 | 3064.16 | 0.000099 |
HEAT PUMP COOLING MODE AIRLOOP F6 NW | 0.251629 | 4104.94 | 2749.77 | 0.000090 |
HEAT PUMP COOLING MODE AIRLOOP F6 SE | 0.258460 | 4265.07 | 2855.71 | 0.000093 |
HEAT PUMP COOLING MODE AIRLOOP F6 NE | 0.189678 | 3206.11 | 2102.50 | 0.000070 |
HEAT PUMP COOLING MODE AIRLOOP F6 N1 | 0.138682 | 2423.03 | 1556.95 | 0.000053 |
HEAT PUMP COOLING MODE AIRLOOP F6 N2 | 0.137192 | 2401.87 | 1541.69 | 0.000052 |
HEAT PUMP COOLING MODE AIRLOOP F6 S1 | 0.195701 | 3317.79 | 2194.71 | 0.000072 |
HEAT PUMP COOLING MODE AIRLOOP F6 S2 | 0.196697 | 3331.48 | 2204.83 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F7 SW | 0.280165 | 4531.05 | 3055.84 | 0.000099 |
HEAT PUMP COOLING MODE AIRLOOP F7 NW | 0.250306 | 4098.41 | 2739.52 | 0.000090 |
HEAT PUMP COOLING MODE AIRLOOP F7 SE | 0.257243 | 4260.11 | 2846.54 | 0.000093 |
HEAT PUMP COOLING MODE AIRLOOP F7 NE | 0.188326 | 3198.15 | 2091.82 | 0.000070 |
HEAT PUMP COOLING MODE AIRLOOP F7 N1 | 0.137687 | 2415.10 | 1548.59 | 0.000053 |
HEAT PUMP COOLING MODE AIRLOOP F7 N2 | 0.136224 | 2402.16 | 1537.87 | 0.000052 |
HEAT PUMP COOLING MODE AIRLOOP F7 S1 | 0.194465 | 3311.28 | 2185.87 | 0.000072 |
HEAT PUMP COOLING MODE AIRLOOP F7 S2 | 0.195450 | 3321.33 | 2194.09 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F8 SW | 0.280003 | 4539.70 | 3057.14 | 0.000099 |
HEAT PUMP COOLING MODE AIRLOOP F8 NW | 0.250292 | 4108.78 | 2742.28 | 0.000090 |
HEAT PUMP COOLING MODE AIRLOOP F8 SE | 0.257223 | 4270.44 | 2849.25 | 0.000093 |
HEAT PUMP COOLING MODE AIRLOOP F8 NE | 0.188198 | 3206.06 | 2093.28 | 0.000070 |
HEAT PUMP COOLING MODE AIRLOOP F8 N1 | 0.137989 | 2432.82 | 1557.60 | 0.000053 |
HEAT PUMP COOLING MODE AIRLOOP F8 N2 | 0.136544 | 2412.22 | 1542.78 | 0.000053 |
HEAT PUMP COOLING MODE AIRLOOP F8 S1 | 0.194445 | 3317.33 | 2187.43 | 0.000072 |
HEAT PUMP COOLING MODE AIRLOOP F8 S2 | 0.195420 | 3327.27 | 2195.55 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F9 SW | 0.288359 | 4659.80 | 3141.73 | 0.000102 |
HEAT PUMP COOLING MODE AIRLOOP F9 NW | 0.258315 | 4229.99 | 2826.85 | 0.000092 |
HEAT PUMP COOLING MODE AIRLOOP F9 SE | 0.262837 | 4361.91 | 2911.17 | 0.000095 |
HEAT PUMP COOLING MODE AIRLOOP F9 NE | 0.190382 | 3256.14 | 2123.84 | 0.000071 |
HEAT PUMP COOLING MODE AIRLOOP F9 N1 | 0.145049 | 2529.98 | 1627.02 | 0.000055 |
HEAT PUMP COOLING MODE AIRLOOP F9 N2 | 0.143571 | 2516.89 | 1616.16 | 0.000055 |
HEAT PUMP COOLING MODE AIRLOOP F9 S1 | 0.199190 | 3389.19 | 2237.53 | 0.000074 |
HEAT PUMP COOLING MODE AIRLOOP F9 S2 | 0.200198 | 3403.08 | 2247.80 | 0.000074 |
HEAT PUMP COOLING MODE AIRLOOP T SW | 0.353571 | 5618.26 | 3836.26 | 0.000123 |
HEAT PUMP COOLING MODE AIRLOOP T NW | 0.306538 | 4926.66 | 3333.21 | 0.000108 |
HEAT PUMP COOLING MODE AIRLOOP T SE | 0.322838 | 5196.96 | 3523.87 | 0.000114 |
HEAT PUMP COOLING MODE AIRLOOP T NE | 0.231503 | 3852.17 | 2552.53 | 0.000084 |
HEAT PUMP COOLING MODE AIRLOOP T N1 | 0.172777 | 3020.72 | 1966.56 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP T N2 | 0.172590 | 3023.29 | 1967.06 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP T S1 | 0.270354 | 4373.50 | 2962.81 | 0.000096 |
HEAT PUMP COOLING MODE AIRLOOP T S2 | 0.271350 | 4387.09 | 2972.92 | 0.000096 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Supplemental Heating Coil Nominal Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
AIRLOOP G SW DXAC HEAT PUMP | 0.209419 | 0.209419 | 0.209419 | 0.209419 | 3451.84 | 3451.84 | 4944.67 | 1.00 |
AIRLOOP G NW DXAC HEAT PUMP | 0.186430 | 0.186430 | 0.186430 | 0.186430 | 3086.52 | 3086.52 | 4965.09 | 1.00 |
AIRLOOP OFFICE DXAC HEAT PUMP | 0.296517 | 0.296517 | 0.296517 | 0.296517 | 4870.99 | 4870.99 | 6214.19 | 1.00 |
AIRLOOP G NE DXAC HEAT PUMP | 0.157158 | 0.157158 | 0.157158 | 0.157158 | 2744.85 | 2744.85 | 4971.91 | 1.00 |
AIRLOOP G N1 DXAC HEAT PUMP | 0.108511 | 0.108511 | 0.108511 | 0.108511 | 2010.15 | 2010.15 | 3939.61 | 1.00 |
AIRLOOP G N2 DXAC HEAT PUMP | 0.108518 | 0.108518 | 0.108518 | 0.108518 | 2019.21 | 2019.21 | 3939.76 | 1.00 |
AIRLOOP G S1 DXAC HEAT PUMP | 0.139654 | 0.139654 | 0.139654 | 0.139654 | 2474.30 | 2474.30 | 3916.93 | 1.00 |
AIRLOOP G S2 DXAC HEAT PUMP | 0.145042 | 0.145042 | 0.145042 | 0.145042 | 2548.46 | 2548.46 | 3925.64 | 1.00 |
AIRLOOP F2 SW DXAC HEAT PUMP | 0.280855 | 0.280855 | 0.280855 | 0.280855 | 4445.64 | 4445.64 | 4606.99 | 1.00 |
AIRLOOP F2 NW DXAC HEAT PUMP | 0.248577 | 0.248577 | 0.248577 | 0.248577 | 3987.51 | 3987.51 | 4616.20 | 1.00 |
AIRLOOP F2 SE DXAC HEAT PUMP | 0.273972 | 0.273972 | 0.273972 | 0.273972 | 4402.78 | 4402.78 | 4637.98 | 1.00 |
AIRLOOP F2 NE DXAC HEAT PUMP | 0.185831 | 0.185831 | 0.185831 | 0.185831 | 3082.89 | 3082.89 | 4622.75 | 1.00 |
AIRLOOP F2 N1 DXAC HEAT PUMP | 0.132945 | 0.132945 | 0.132945 | 0.132945 | 2303.16 | 2303.16 | 3382.29 | 1.00 |
AIRLOOP F2 N2 DXAC HEAT PUMP | 0.131420 | 0.131420 | 0.131420 | 0.131420 | 2281.65 | 2281.65 | 3382.44 | 1.00 |
AIRLOOP F2 S1 DXAC HEAT PUMP | 0.191216 | 0.191216 | 0.191216 | 0.191216 | 3214.86 | 3214.86 | 3376.40 | 1.00 |
AIRLOOP F2 S2 DXAC HEAT PUMP | 0.193379 | 0.193379 | 0.193379 | 0.193379 | 3240.92 | 3240.92 | 3378.03 | 1.00 |
AIRLOOP F3 SW DXAC HEAT PUMP | 0.282383 | 0.282383 | 0.282383 | 0.282383 | 4493.56 | 4493.56 | 4574.00 | 1.00 |
AIRLOOP F3 NW DXAC HEAT PUMP | 0.251635 | 0.251635 | 0.251635 | 0.251635 | 4055.97 | 4055.97 | 4583.34 | 1.00 |
AIRLOOP F3 SE DXAC HEAT PUMP | 0.259973 | 0.259973 | 0.259973 | 0.259973 | 4236.71 | 4236.71 | 4581.52 | 1.00 |
AIRLOOP F3 NE DXAC HEAT PUMP | 0.189861 | 0.189861 | 0.189861 | 0.189861 | 3163.11 | 3163.11 | 4588.38 | 1.00 |
AIRLOOP F3 N1 DXAC HEAT PUMP | 0.137466 | 0.137466 | 0.137466 | 0.137466 | 2380.30 | 2380.30 | 3304.67 | 1.00 |
AIRLOOP F3 N2 DXAC HEAT PUMP | 0.135954 | 0.135954 | 0.135954 | 0.135954 | 2358.96 | 2358.96 | 3304.78 | 1.00 |
AIRLOOP F3 S1 DXAC HEAT PUMP | 0.195308 | 0.195308 | 0.195308 | 0.195308 | 3283.11 | 3283.11 | 3296.71 | 1.00 |
AIRLOOP F3 S2 DXAC HEAT PUMP | 0.196474 | 0.196474 | 0.196474 | 0.196474 | 3299.11 | 3299.11 | 3297.03 | 1.00 |
AIRLOOP F4 SW DXAC HEAT PUMP | 0.282905 | 0.282905 | 0.282905 | 0.282905 | 4520.85 | 4520.85 | 4633.69 | 1.00 |
AIRLOOP F4 NW DXAC HEAT PUMP | 0.252513 | 0.252513 | 0.252513 | 0.252513 | 4087.71 | 4087.71 | 4641.73 | 1.00 |
AIRLOOP F4 SE DXAC HEAT PUMP | 0.259290 | 0.259290 | 0.259290 | 0.259290 | 4246.99 | 4246.99 | 4637.60 | 1.00 |
AIRLOOP F4 NE DXAC HEAT PUMP | 0.190659 | 0.190659 | 0.190659 | 0.190659 | 3192.47 | 3192.47 | 4645.39 | 1.00 |
AIRLOOP F4 N1 DXAC HEAT PUMP | 0.138841 | 0.138841 | 0.138841 | 0.138841 | 2409.90 | 2409.90 | 3325.06 | 1.00 |
AIRLOOP F4 N2 DXAC HEAT PUMP | 0.137335 | 0.137335 | 0.137335 | 0.137335 | 2388.59 | 2388.59 | 3325.14 | 1.00 |
AIRLOOP F4 S1 DXAC HEAT PUMP | 0.196368 | 0.196368 | 0.196368 | 0.196368 | 3309.40 | 3309.40 | 3318.11 | 1.00 |
AIRLOOP F4 S2 DXAC HEAT PUMP | 0.197386 | 0.197386 | 0.197386 | 0.197386 | 3323.39 | 3323.39 | 3318.22 | 1.00 |
AIRLOOP M SW DXAC HEAT PUMP | 0.285533 | 0.285533 | 0.285533 | 0.285533 | 4573.47 | 4573.47 | 4672.87 | 1.00 |
AIRLOOP M NW DXAC HEAT PUMP | 0.255443 | 0.255443 | 0.255443 | 0.255443 | 4144.18 | 4144.18 | 4678.04 | 1.00 |
AIRLOOP M SE DXAC HEAT PUMP | 0.262066 | 0.262066 | 0.262066 | 0.262066 | 4301.34 | 4301.34 | 4675.30 | 1.00 |
AIRLOOP M NE DXAC HEAT PUMP | 0.193466 | 0.193466 | 0.193466 | 0.193466 | 3246.30 | 3246.30 | 4680.45 | 1.00 |
AIRLOOP M N1 DXAC HEAT PUMP | 0.141995 | 0.141995 | 0.141995 | 0.141995 | 2462.66 | 2462.66 | 3331.45 | 1.00 |
AIRLOOP M N2 DXAC HEAT PUMP | 0.140493 | 0.140493 | 0.140493 | 0.140493 | 2441.40 | 2441.40 | 3331.50 | 1.00 |
AIRLOOP M S1 DXAC HEAT PUMP | 0.199303 | 0.199303 | 0.199303 | 0.199303 | 3359.48 | 3359.48 | 3327.35 | 1.00 |
AIRLOOP M S2 DXAC HEAT PUMP | 0.200300 | 0.200300 | 0.200300 | 0.200300 | 3373.17 | 3373.17 | 3327.41 | 1.00 |
AIRLOOP F6 SW DXAC HEAT PUMP | 0.281638 | 0.281638 | 0.281638 | 0.281638 | 4533.54 | 4533.54 | 4778.63 | 1.00 |
AIRLOOP F6 NW DXAC HEAT PUMP | 0.251629 | 0.251629 | 0.251629 | 0.251629 | 4104.94 | 4104.94 | 4783.03 | 1.00 |
AIRLOOP F6 SE DXAC HEAT PUMP | 0.258460 | 0.258460 | 0.258460 | 0.258460 | 4265.07 | 4265.07 | 4779.91 | 1.00 |
AIRLOOP F6 NE DXAC HEAT PUMP | 0.189678 | 0.189678 | 0.189678 | 0.189678 | 3206.11 | 3206.11 | 4784.30 | 1.00 |
AIRLOOP F6 N1 DXAC HEAT PUMP | 0.138682 | 0.138682 | 0.138682 | 0.138682 | 2423.03 | 2423.03 | 3409.09 | 1.00 |
AIRLOOP F6 N2 DXAC HEAT PUMP | 0.137192 | 0.137192 | 0.137192 | 0.137192 | 2401.87 | 2401.87 | 3409.12 | 1.00 |
AIRLOOP F6 S1 DXAC HEAT PUMP | 0.195701 | 0.195701 | 0.195701 | 0.195701 | 3317.79 | 3317.79 | 3405.73 | 1.00 |
AIRLOOP F6 S2 DXAC HEAT PUMP | 0.196697 | 0.196697 | 0.196697 | 0.196697 | 3331.48 | 3331.48 | 3405.76 | 1.00 |
AIRLOOP F7 SW DXAC HEAT PUMP | 0.280165 | 0.280165 | 0.280165 | 0.280165 | 4531.05 | 4531.05 | 4853.25 | 1.00 |
AIRLOOP F7 NW DXAC HEAT PUMP | 0.250306 | 0.250306 | 0.250306 | 0.250306 | 4098.41 | 4098.41 | 4855.79 | 1.00 |
AIRLOOP F7 SE DXAC HEAT PUMP | 0.257243 | 0.257243 | 0.257243 | 0.257243 | 4260.11 | 4260.11 | 4853.49 | 1.00 |
AIRLOOP F7 NE DXAC HEAT PUMP | 0.188326 | 0.188326 | 0.188326 | 0.188326 | 3198.15 | 3198.15 | 4856.03 | 1.00 |
AIRLOOP F7 N1 DXAC HEAT PUMP | 0.137687 | 0.137687 | 0.137687 | 0.137687 | 2415.10 | 2415.10 | 3458.97 | 1.00 |
AIRLOOP F7 N2 DXAC HEAT PUMP | 0.136224 | 0.136224 | 0.136224 | 0.136224 | 2402.16 | 2402.16 | 3458.98 | 1.00 |
AIRLOOP F7 S1 DXAC HEAT PUMP | 0.194465 | 0.194465 | 0.194465 | 0.194465 | 3311.28 | 3311.28 | 3457.51 | 1.00 |
AIRLOOP F7 S2 DXAC HEAT PUMP | 0.195450 | 0.195450 | 0.195450 | 0.195450 | 3321.33 | 3321.33 | 3457.52 | 1.00 |
AIRLOOP F8 SW DXAC HEAT PUMP | 0.280003 | 0.280003 | 0.280003 | 0.280003 | 4539.70 | 4539.70 | 4937.27 | 1.00 |
AIRLOOP F8 NW DXAC HEAT PUMP | 0.250292 | 0.250292 | 0.250292 | 0.250292 | 4108.78 | 4108.78 | 4937.70 | 1.00 |
AIRLOOP F8 SE DXAC HEAT PUMP | 0.257223 | 0.257223 | 0.257223 | 0.257223 | 4270.44 | 4270.44 | 4936.56 | 1.00 |
AIRLOOP F8 NE DXAC HEAT PUMP | 0.188198 | 0.188198 | 0.188198 | 0.188198 | 3206.06 | 3206.06 | 4936.99 | 1.00 |
AIRLOOP F8 N1 DXAC HEAT PUMP | 0.137989 | 0.137989 | 0.137989 | 0.137989 | 2432.82 | 2432.82 | 3520.85 | 1.00 |
AIRLOOP F8 N2 DXAC HEAT PUMP | 0.136544 | 0.136544 | 0.136544 | 0.136544 | 2412.22 | 2412.22 | 3520.83 | 1.00 |
AIRLOOP F8 S1 DXAC HEAT PUMP | 0.194445 | 0.194445 | 0.194445 | 0.194445 | 3317.33 | 3317.33 | 3521.49 | 1.00 |
AIRLOOP F8 S2 DXAC HEAT PUMP | 0.195420 | 0.195420 | 0.195420 | 0.195420 | 3327.27 | 3327.27 | 3521.48 | 1.00 |
AIRLOOP F9 SW DXAC HEAT PUMP | 0.288359 | 0.288359 | 0.288359 | 0.288359 | 4659.80 | 4659.80 | 5217.07 | 1.00 |
AIRLOOP F9 NW DXAC HEAT PUMP | 0.258315 | 0.258315 | 0.258315 | 0.258315 | 4229.99 | 4229.99 | 5212.12 | 1.00 |
AIRLOOP F9 SE DXAC HEAT PUMP | 0.262837 | 0.262837 | 0.262837 | 0.262837 | 4361.91 | 4361.91 | 5215.46 | 1.00 |
AIRLOOP F9 NE DXAC HEAT PUMP | 0.190382 | 0.190382 | 0.190382 | 0.190382 | 3256.14 | 3256.14 | 5210.51 | 1.00 |
AIRLOOP F9 N1 DXAC HEAT PUMP | 0.145049 | 0.145049 | 0.145049 | 0.145049 | 2529.98 | 2529.98 | 3765.56 | 1.00 |
AIRLOOP F9 N2 DXAC HEAT PUMP | 0.143571 | 0.143571 | 0.143571 | 0.143571 | 2516.89 | 2516.89 | 3765.53 | 1.00 |
AIRLOOP F9 S1 DXAC HEAT PUMP | 0.199190 | 0.199190 | 0.199190 | 0.199190 | 3389.19 | 3389.19 | 3771.14 | 1.00 |
AIRLOOP F9 S2 DXAC HEAT PUMP | 0.200198 | 0.200198 | 0.200198 | 0.200198 | 3403.08 | 3403.08 | 3771.10 | 1.00 |
AIRLOOP T SW DXAC HEAT PUMP | 0.353571 | 0.353571 | 0.353571 | 0.353571 | 5618.26 | 5618.26 | 6357.66 | 1.00 |
AIRLOOP T NW DXAC HEAT PUMP | 0.306538 | 0.306538 | 0.306538 | 0.306538 | 4926.66 | 4926.66 | 6361.29 | 1.00 |
AIRLOOP T SE DXAC HEAT PUMP | 0.322838 | 0.322838 | 0.322838 | 0.322838 | 5196.96 | 5196.96 | 6355.44 | 1.00 |
AIRLOOP T NE DXAC HEAT PUMP | 0.231503 | 0.231503 | 0.231503 | 0.231503 | 3852.17 | 3852.17 | 6359.08 | 1.00 |
AIRLOOP T N1 DXAC HEAT PUMP | 0.172777 | 0.172777 | 0.172777 | 0.172777 | 3020.72 | 3020.72 | 4970.24 | 1.00 |
AIRLOOP T N2 DXAC HEAT PUMP | 0.172590 | 0.172590 | 0.172590 | 0.172590 | 3023.29 | 3023.29 | 4970.19 | 1.00 |
AIRLOOP T S1 DXAC HEAT PUMP | 0.270354 | 0.270354 | 0.270354 | 0.270354 | 4373.50 | 4373.50 | 4964.21 | 1.00 |
AIRLOOP T S2 DXAC HEAT PUMP | 0.271350 | 0.271350 | 0.271350 | 0.271350 | 4387.09 | 4387.09 | 4964.16 | 1.00 |
Maximum Flow Rate [m3/s] | |
AIRLOOP G SW SUPPLY FAN | 0.209419 |
AIRLOOP G NW SUPPLY FAN | 0.186430 |
AIRLOOP OFFICE SUPPLY FAN | 0.296517 |
AIRLOOP G NE SUPPLY FAN | 0.157158 |
AIRLOOP G N1 SUPPLY FAN | 0.108511 |
AIRLOOP G N2 SUPPLY FAN | 0.108518 |
AIRLOOP G S1 SUPPLY FAN | 0.139654 |
AIRLOOP G S2 SUPPLY FAN | 0.145042 |
AIRLOOP F2 SW SUPPLY FAN | 0.280855 |
AIRLOOP F2 NW SUPPLY FAN | 0.248577 |
AIRLOOP F2 SE SUPPLY FAN | 0.273972 |
AIRLOOP F2 NE SUPPLY FAN | 0.185831 |
AIRLOOP F2 N1 SUPPLY FAN | 0.132945 |
AIRLOOP F2 N2 SUPPLY FAN | 0.131420 |
AIRLOOP F2 S1 SUPPLY FAN | 0.191216 |
AIRLOOP F2 S2 SUPPLY FAN | 0.193379 |
AIRLOOP F3 SW SUPPLY FAN | 0.282383 |
AIRLOOP F3 NW SUPPLY FAN | 0.251635 |
AIRLOOP F3 SE SUPPLY FAN | 0.259973 |
AIRLOOP F3 NE SUPPLY FAN | 0.189861 |
AIRLOOP F3 N1 SUPPLY FAN | 0.137466 |
AIRLOOP F3 N2 SUPPLY FAN | 0.135954 |
AIRLOOP F3 S1 SUPPLY FAN | 0.195308 |
AIRLOOP F3 S2 SUPPLY FAN | 0.196474 |
AIRLOOP F4 SW SUPPLY FAN | 0.282905 |
AIRLOOP F4 NW SUPPLY FAN | 0.252513 |
AIRLOOP F4 SE SUPPLY FAN | 0.259290 |
AIRLOOP F4 NE SUPPLY FAN | 0.190659 |
AIRLOOP F4 N1 SUPPLY FAN | 0.138841 |
AIRLOOP F4 N2 SUPPLY FAN | 0.137335 |
AIRLOOP F4 S1 SUPPLY FAN | 0.196368 |
AIRLOOP F4 S2 SUPPLY FAN | 0.197386 |
AIRLOOP M SW SUPPLY FAN | 0.285533 |
AIRLOOP M NW SUPPLY FAN | 0.255443 |
AIRLOOP M SE SUPPLY FAN | 0.262066 |
AIRLOOP M NE SUPPLY FAN | 0.193466 |
AIRLOOP M N1 SUPPLY FAN | 0.141995 |
AIRLOOP M N2 SUPPLY FAN | 0.140493 |
AIRLOOP M S1 SUPPLY FAN | 0.199303 |
AIRLOOP M S2 SUPPLY FAN | 0.200300 |
AIRLOOP F6 SW SUPPLY FAN | 0.281638 |
AIRLOOP F6 NW SUPPLY FAN | 0.251629 |
AIRLOOP F6 SE SUPPLY FAN | 0.258460 |
AIRLOOP F6 NE SUPPLY FAN | 0.189678 |
AIRLOOP F6 N1 SUPPLY FAN | 0.138682 |
AIRLOOP F6 N2 SUPPLY FAN | 0.137192 |
AIRLOOP F6 S1 SUPPLY FAN | 0.195701 |
AIRLOOP F6 S2 SUPPLY FAN | 0.196697 |
AIRLOOP F7 SW SUPPLY FAN | 0.280165 |
AIRLOOP F7 NW SUPPLY FAN | 0.250306 |
AIRLOOP F7 SE SUPPLY FAN | 0.257243 |
AIRLOOP F7 NE SUPPLY FAN | 0.188326 |
AIRLOOP F7 N1 SUPPLY FAN | 0.137687 |
AIRLOOP F7 N2 SUPPLY FAN | 0.136224 |
AIRLOOP F7 S1 SUPPLY FAN | 0.194465 |
AIRLOOP F7 S2 SUPPLY FAN | 0.195450 |
AIRLOOP F8 SW SUPPLY FAN | 0.280003 |
AIRLOOP F8 NW SUPPLY FAN | 0.250292 |
AIRLOOP F8 SE SUPPLY FAN | 0.257223 |
AIRLOOP F8 NE SUPPLY FAN | 0.188198 |
AIRLOOP F8 N1 SUPPLY FAN | 0.137989 |
AIRLOOP F8 N2 SUPPLY FAN | 0.136544 |
AIRLOOP F8 S1 SUPPLY FAN | 0.194445 |
AIRLOOP F8 S2 SUPPLY FAN | 0.195420 |
AIRLOOP F9 SW SUPPLY FAN | 0.288359 |
AIRLOOP F9 NW SUPPLY FAN | 0.258315 |
AIRLOOP F9 SE SUPPLY FAN | 0.262837 |
AIRLOOP F9 NE SUPPLY FAN | 0.190382 |
AIRLOOP F9 N1 SUPPLY FAN | 0.145049 |
AIRLOOP F9 N2 SUPPLY FAN | 0.143571 |
AIRLOOP F9 S1 SUPPLY FAN | 0.199190 |
AIRLOOP F9 S2 SUPPLY FAN | 0.200198 |
AIRLOOP T SW SUPPLY FAN | 0.353571 |
AIRLOOP T NW SUPPLY FAN | 0.306538 |
AIRLOOP T SE SUPPLY FAN | 0.322838 |
AIRLOOP T NE SUPPLY FAN | 0.231503 |
AIRLOOP T N1 SUPPLY FAN | 0.172777 |
AIRLOOP T N2 SUPPLY FAN | 0.172590 |
AIRLOOP T S1 SUPPLY FAN | 0.270354 |
AIRLOOP T S2 SUPPLY FAN | 0.271350 |
Rated Air Flow Rate [m3/s] | Rated Heating Capacity [W] | Rated Water Flow Rate [m3/s] | |
HEAT PUMP HEATING MODE AIRLOOP G SW | 0.209419 | 3451.84 | 0.000075 |
HEAT PUMP HEATING MODE AIRLOOP G NW | 0.186430 | 3086.52 | 0.000067 |
HEAT PUMP HEATING MODE AIRLOOP OFFICE | 0.296517 | 4870.99 | 0.000106 |
HEAT PUMP HEATING MODE AIRLOOP G NE | 0.157158 | 2744.85 | 0.000060 |
HEAT PUMP HEATING MODE AIRLOOP G N1 | 0.108511 | 2010.15 | 0.000044 |
HEAT PUMP HEATING MODE AIRLOOP G N2 | 0.108518 | 2019.21 | 0.000044 |
HEAT PUMP HEATING MODE AIRLOOP G S1 | 0.139654 | 2474.30 | 0.000054 |
HEAT PUMP HEATING MODE AIRLOOP G S2 | 0.145042 | 2548.46 | 0.000056 |
HEAT PUMP HEATING MODE AIRLOOP F2 SW | 0.280855 | 4445.64 | 0.000097 |
HEAT PUMP HEATING MODE AIRLOOP F2 NW | 0.248577 | 3987.51 | 0.000087 |
HEAT PUMP HEATING MODE AIRLOOP F2 SE | 0.273972 | 4402.78 | 0.000096 |
HEAT PUMP HEATING MODE AIRLOOP F2 NE | 0.185831 | 3082.89 | 0.000067 |
HEAT PUMP HEATING MODE AIRLOOP F2 N1 | 0.132945 | 2303.16 | 0.000050 |
HEAT PUMP HEATING MODE AIRLOOP F2 N2 | 0.131420 | 2281.65 | 0.000050 |
HEAT PUMP HEATING MODE AIRLOOP F2 S1 | 0.191216 | 3214.86 | 0.000070 |
HEAT PUMP HEATING MODE AIRLOOP F2 S2 | 0.193379 | 3240.92 | 0.000071 |
HEAT PUMP HEATING MODE AIRLOOP F3 SW | 0.282383 | 4493.56 | 0.000098 |
HEAT PUMP HEATING MODE AIRLOOP F3 NW | 0.251635 | 4055.97 | 0.000089 |
HEAT PUMP HEATING MODE AIRLOOP F3 SE | 0.259973 | 4236.71 | 0.000093 |
HEAT PUMP HEATING MODE AIRLOOP F3 NE | 0.189861 | 3163.11 | 0.000069 |
HEAT PUMP HEATING MODE AIRLOOP F3 N1 | 0.137466 | 2380.30 | 0.000052 |
HEAT PUMP HEATING MODE AIRLOOP F3 N2 | 0.135954 | 2358.96 | 0.000052 |
HEAT PUMP HEATING MODE AIRLOOP F3 S1 | 0.195308 | 3283.11 | 0.000072 |
HEAT PUMP HEATING MODE AIRLOOP F3 S2 | 0.196474 | 3299.11 | 0.000072 |
HEAT PUMP HEATING MODE AIRLOOP F4 SW | 0.282905 | 4520.85 | 0.000099 |
HEAT PUMP HEATING MODE AIRLOOP F4 NW | 0.252513 | 4087.71 | 0.000089 |
HEAT PUMP HEATING MODE AIRLOOP F4 SE | 0.259290 | 4246.99 | 0.000093 |
HEAT PUMP HEATING MODE AIRLOOP F4 NE | 0.190659 | 3192.47 | 0.000070 |
HEAT PUMP HEATING MODE AIRLOOP F4 N1 | 0.138841 | 2409.90 | 0.000053 |
HEAT PUMP HEATING MODE AIRLOOP F4 N2 | 0.137335 | 2388.59 | 0.000052 |
HEAT PUMP HEATING MODE AIRLOOP F4 S1 | 0.196368 | 3309.40 | 0.000072 |
HEAT PUMP HEATING MODE AIRLOOP F4 S2 | 0.197386 | 3323.39 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP M SW | 0.285533 | 4573.47 | 0.000100 |
HEAT PUMP HEATING MODE AIRLOOP M NW | 0.255443 | 4144.18 | 0.000091 |
HEAT PUMP HEATING MODE AIRLOOP M SE | 0.262066 | 4301.34 | 0.000094 |
HEAT PUMP HEATING MODE AIRLOOP M NE | 0.193466 | 3246.30 | 0.000071 |
HEAT PUMP HEATING MODE AIRLOOP M N1 | 0.141995 | 2462.66 | 0.000054 |
HEAT PUMP HEATING MODE AIRLOOP M N2 | 0.140493 | 2441.40 | 0.000053 |
HEAT PUMP HEATING MODE AIRLOOP M S1 | 0.199303 | 3359.48 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP M S2 | 0.200300 | 3373.17 | 0.000074 |
HEAT PUMP HEATING MODE AIRLOOP F6 SW | 0.281638 | 4533.54 | 0.000099 |
HEAT PUMP HEATING MODE AIRLOOP F6 NW | 0.251629 | 4104.94 | 0.000090 |
HEAT PUMP HEATING MODE AIRLOOP F6 SE | 0.258460 | 4265.07 | 0.000093 |
HEAT PUMP HEATING MODE AIRLOOP F6 NE | 0.189678 | 3206.11 | 0.000070 |
HEAT PUMP HEATING MODE AIRLOOP F6 N1 | 0.138682 | 2423.03 | 0.000053 |
HEAT PUMP HEATING MODE AIRLOOP F6 N2 | 0.137192 | 2401.87 | 0.000052 |
HEAT PUMP HEATING MODE AIRLOOP F6 S1 | 0.195701 | 3317.79 | 0.000072 |
HEAT PUMP HEATING MODE AIRLOOP F6 S2 | 0.196697 | 3331.48 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F7 SW | 0.280165 | 4531.05 | 0.000099 |
HEAT PUMP HEATING MODE AIRLOOP F7 NW | 0.250306 | 4098.41 | 0.000090 |
HEAT PUMP HEATING MODE AIRLOOP F7 SE | 0.257243 | 4260.11 | 0.000093 |
HEAT PUMP HEATING MODE AIRLOOP F7 NE | 0.188326 | 3198.15 | 0.000070 |
HEAT PUMP HEATING MODE AIRLOOP F7 N1 | 0.137687 | 2415.10 | 0.000053 |
HEAT PUMP HEATING MODE AIRLOOP F7 N2 | 0.136224 | 2402.16 | 0.000052 |
HEAT PUMP HEATING MODE AIRLOOP F7 S1 | 0.194465 | 3311.28 | 0.000072 |
HEAT PUMP HEATING MODE AIRLOOP F7 S2 | 0.195450 | 3321.33 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F8 SW | 0.280003 | 4539.70 | 0.000099 |
HEAT PUMP HEATING MODE AIRLOOP F8 NW | 0.250292 | 4108.78 | 0.000090 |
HEAT PUMP HEATING MODE AIRLOOP F8 SE | 0.257223 | 4270.44 | 0.000093 |
HEAT PUMP HEATING MODE AIRLOOP F8 NE | 0.188198 | 3206.06 | 0.000070 |
HEAT PUMP HEATING MODE AIRLOOP F8 N1 | 0.137989 | 2432.82 | 0.000053 |
HEAT PUMP HEATING MODE AIRLOOP F8 N2 | 0.136544 | 2412.22 | 0.000053 |
HEAT PUMP HEATING MODE AIRLOOP F8 S1 | 0.194445 | 3317.33 | 0.000072 |
HEAT PUMP HEATING MODE AIRLOOP F8 S2 | 0.195420 | 3327.27 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F9 SW | 0.288359 | 4659.80 | 0.000102 |
HEAT PUMP HEATING MODE AIRLOOP F9 NW | 0.258315 | 4229.99 | 0.000092 |
HEAT PUMP HEATING MODE AIRLOOP F9 SE | 0.262837 | 4361.91 | 0.000095 |
HEAT PUMP HEATING MODE AIRLOOP F9 NE | 0.190382 | 3256.14 | 0.000071 |
HEAT PUMP HEATING MODE AIRLOOP F9 N1 | 0.145049 | 2529.98 | 0.000055 |
HEAT PUMP HEATING MODE AIRLOOP F9 N2 | 0.143571 | 2516.89 | 0.000055 |
HEAT PUMP HEATING MODE AIRLOOP F9 S1 | 0.199190 | 3389.19 | 0.000074 |
HEAT PUMP HEATING MODE AIRLOOP F9 S2 | 0.200198 | 3403.08 | 0.000074 |
HEAT PUMP HEATING MODE AIRLOOP T SW | 0.353571 | 5618.26 | 0.000123 |
HEAT PUMP HEATING MODE AIRLOOP T NW | 0.306538 | 4926.66 | 0.000108 |
HEAT PUMP HEATING MODE AIRLOOP T SE | 0.322838 | 5196.96 | 0.000114 |
HEAT PUMP HEATING MODE AIRLOOP T NE | 0.231503 | 3852.17 | 0.000084 |
HEAT PUMP HEATING MODE AIRLOOP T N1 | 0.172777 | 3020.72 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP T N2 | 0.172590 | 3023.29 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP T S1 | 0.270354 | 4373.50 | 0.000096 |
HEAT PUMP HEATING MODE AIRLOOP T S2 | 0.271350 | 4387.09 | 0.000096 |
Nominal Capacity [W] | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW | 4944.67 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW | 4965.09 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE | 6214.19 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE | 4971.91 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 | 3939.61 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 | 3939.76 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 | 3916.93 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 | 3925.64 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW | 4606.99 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW | 4616.20 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE | 4637.98 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE | 4622.75 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 | 3382.29 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 | 3382.44 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 | 3376.40 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 | 3378.03 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW | 4574.00 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW | 4583.34 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE | 4581.52 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE | 4588.38 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 | 3304.67 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 | 3304.78 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 | 3296.71 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 | 3297.03 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW | 4633.69 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW | 4641.73 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE | 4637.60 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE | 4645.39 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 | 3325.06 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 | 3325.14 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 | 3318.11 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 | 3318.22 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW | 4672.87 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW | 4678.04 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE | 4675.30 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE | 4680.45 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 | 3331.45 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 | 3331.50 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 | 3327.35 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 | 3327.41 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW | 4778.63 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW | 4783.03 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE | 4779.91 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE | 4784.30 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 | 3409.09 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 | 3409.12 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 | 3405.73 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 | 3405.76 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW | 4853.25 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW | 4855.79 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE | 4853.49 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE | 4856.03 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 | 3458.97 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 | 3458.98 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 | 3457.51 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 | 3457.52 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW | 4937.27 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW | 4937.70 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE | 4936.56 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE | 4936.99 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 | 3520.85 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 | 3520.83 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 | 3521.49 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 | 3521.48 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW | 5217.07 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW | 5212.12 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE | 5215.46 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE | 5210.51 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 | 3765.56 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 | 3765.53 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 | 3771.14 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 | 3771.10 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW | 6357.66 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW | 6361.29 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE | 6355.44 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE | 6359.08 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 | 4970.24 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 | 4970.19 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 | 4964.21 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 | 4964.16 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
SHWSYS1 | 0.000289 | 0.325214 |
SINGLE WATER PLANT LOOP | 0.006079 | 6.84 |
Design Water Flow Rate [m3/s] | |
CENTRAL BOILER | 0.006079 |
Use Side Design Flow Rate [m3/s] | |
SHWSYS1 WATER HEATER | 0.000289 |
Design Water Flow Rate [m3/s] | Fan Power at Design Air Flow Rate [W] | Design Air Flow Rate [m3/s] | U-Factor Times Area Value at Design Air Flow Rate [W/C] | |
CENTRAL TOWER | 0.006079 | 2934.76 | 8.06 | 8723.50 |
Rated Flow Rate [m3/s] | Rated Power Consumption [W] | |
SHWSYS1 PUMP | 0.000289 | 36.93 |
PLANT CIRC PUMP | 0.006079 | 1550.54 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:12
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW3 | |
G WWALL SWA | GWINDOW2 | |
G NWALL NWA | GWINDOW4 | |
G WWALL NWA | GWINDOW6 | |
G SWALL SEA | GWINDOW1 | |
G EWALL SEA | GWINDOW8 | |
G NWALL NEA | GWINDOW5 | |
G EWALL NEA | GWINDOW7 | |
G NWALL N1A | GWINDOW9 | |
G NWALL N2A | GWINDOW10 | |
G SWALL S1A | GWINDOW11 | |
G SWALL S2A | GWINDOW12 | |
G WWALL C | GWINDOW13 | |
G EWALL C | ENTRANCE DOOR | |
F2 WWALL SWA | F2WINDOW2 | |
F2 SWALL SWA | F2WINDOW3 | |
F2 NWALL NWA | F2WINDOW4 | |
F2 WWALL NWA | F2WINDOW6 | |
F2 EWALL SEA | F2WINDOW8 | |
F2 SWALL SEA | F2WINDOW1 | |
F2 NWALL NEA | F2WINDOW5 | |
F2 EWALL NEA | F2WINDOW7 | |
F2 NWALL N1A | F2WINDOW9 | |
F2 NWALL N2A | F2WINDOW10 | |
F2 SWALL S1A | F2WINDOW11 | |
F2 SWALL S2A | F2WINDOW12 | |
F2 WWALL C | F2WINDOW13 | |
F2 EWALL C | F2WINDOW14 | |
F3 WWALL SWA | F3WINDOW2 | |
F3 SWALL SWA | F3WINDOW3 | |
F3 NWALL NWA | F3WINDOW4 | |
F3 WWALL NWA | F3WINDOW6 | |
F3 EWALL SEA | F3WINDOW8 | |
F3 SWALL SEA | F3WINDOW1 | |
F3 NWALL NEA | F3WINDOW5 | |
F3 EWALL NEA | F3WINDOW7 | |
F3 NWALL N1A | F3WINDOW9 | |
F3 NWALL N2A | F3WINDOW10 | |
F3 SWALL S1A | F3WINDOW11 | |
F3 SWALL S2A | F3WINDOW12 | |
F3 WWALL C | F3WINDOW13 | |
F3 EWALL C | F3WINDOW14 | |
F4 WWALL SWA | F4WINDOW2 | |
F4 SWALL SWA | F4WINDOW3 | |
F4 NWALL NWA | F4WINDOW4 | |
F4 WWALL NWA | F4WINDOW6 | |
F4 EWALL SEA | F4WINDOW8 | |
F4 SWALL SEA | F4WINDOW1 | |
F4 NWALL NEA | F4WINDOW5 | |
F4 EWALL NEA | F4WINDOW7 | |
F4 NWALL N1A | F4WINDOW9 | |
F4 NWALL N2A | F4WINDOW10 | |
F4 SWALL S1A | F4WINDOW11 | |
F4 SWALL S2A | F4WINDOW12 | |
F4 WWALL C | F4WINDOW13 | |
F4 EWALL C | F4WINDOW14 | |
M WWALL SWA | MWINDOW2 | |
M SWALL SWA | MWINDOW3 | |
M NWALL NWA | MWINDOW4 | |
M WWALL NWA | MWINDOW6 | |
M EWALL SEA | MWINDOW8 | |
M SWALL SEA | MWINDOW1 | |
M NWALL NEA | MWINDOW5 | |
M EWALL NEA | MWINDOW7 | |
M NWALL N1A | MWINDOW9 | |
M NWALL N2A | MWINDOW10 | |
M SWALL S1A | MWINDOW11 | |
M SWALL S2A | MWINDOW12 | |
M WWALL C | MWINDOW13 | |
M EWALL C | MWINDOW14 | |
F6 WWALL SWA | F6WINDOW2 | |
F6 SWALL SWA | F6WINDOW3 | |
F6 NWALL NWA | F6WINDOW4 | |
F6 WWALL NWA | F6WINDOW6 | |
F6 EWALL SEA | F6WINDOW8 | |
F6 SWALL SEA | F6WINDOW1 | |
F6 NWALL NEA | F6WINDOW5 | |
F6 EWALL NEA | F6WINDOW7 | |
F6 NWALL N1A | F6WINDOW9 | |
F6 NWALL N2A | F6WINDOW10 | |
F6 SWALL S1A | F6WINDOW11 | |
F6 SWALL S2A | F6WINDOW12 | |
F6 WWALL C | F6WINDOW13 | |
F6 EWALL C | F6WINDOW14 | |
F7 WWALL SWA | F7WINDOW2 | |
F7 SWALL SWA | F7WINDOW3 | |
F7 NWALL NWA | F7WINDOW4 | |
F7 WWALL NWA | F7WINDOW6 | |
F7 EWALL SEA | F7WINDOW8 | |
F7 SWALL SEA | F7WINDOW1 | |
F7 NWALL NEA | F7WINDOW5 | |
F7 EWALL NEA | F7WINDOW7 | |
F7 NWALL N1A | F7WINDOW9 | |
F7 NWALL N2A | F7WINDOW10 | |
F7 SWALL S1A | F7WINDOW11 | |
F7 SWALL S2A | F7WINDOW12 | |
F7 WWALL C | F7WINDOW13 | |
F7 EWALL C | F7WINDOW14 | |
F8 WWALL SWA | F8WINDOW2 | |
F8 SWALL SWA | F8WINDOW3 | |
F8 NWALL NWA | F8WINDOW4 | |
F8 WWALL NWA | F8WINDOW6 | |
F8 EWALL SEA | F8WINDOW8 | |
F8 SWALL SEA | F8WINDOW1 | |
F8 NWALL NEA | F8WINDOW5 | |
F8 EWALL NEA | F8WINDOW7 | |
F8 NWALL N1A | F8WINDOW9 | |
F8 NWALL N2A | F8WINDOW10 | |
F8 SWALL S1A | F8WINDOW11 | |
F8 SWALL S2A | F8WINDOW12 | |
F8 WWALL C | F8WINDOW13 | |
F8 EWALL C | F8WINDOW14 | |
F9 WWALL SWA | F9WINDOW2 | |
F9 SWALL SWA | F9WINDOW3 | |
F9 NWALL NWA | F9WINDOW4 | |
F9 WWALL NWA | F9WINDOW6 | |
F9 EWALL SEA | F9WINDOW8 | |
F9 SWALL SEA | F9WINDOW1 | |
F9 NWALL NEA | F9WINDOW5 | |
F9 EWALL NEA | F9WINDOW7 | |
F9 NWALL N1A | F9WINDOW9 | |
F9 NWALL N2A | F9WINDOW10 | |
F9 SWALL S1A | F9WINDOW11 | |
F9 SWALL S2A | F9WINDOW12 | |
F9 WWALL C | F9WINDOW13 | |
F9 EWALL C | F9WINDOW14 | |
T WWALL SWA | TWINDOW2 | |
T SWALL SWA | TWINDOW3 | |
T NWALL NWA | TWINDOW4 | |
T WWALL NWA | TWINDOW6 | |
T EWALL SEA | TWINDOW8 | |
T SWALL SEA | TWINDOW1 | |
T NWALL NEA | TWINDOW5 | |
T EWALL NEA | TWINDOW7 | |
T NWALL N1A | TWINDOW9 | |
T NWALL N2A | TWINDOW10 | |
T SWALL S1A | TWINDOW11 | |
T SWALL S2A | TWINDOW12 | |
T WWALL C | TWINDOW13 | |
T EWALL C | TWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:12
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.77 | -11.6 |
March | 21.86 | -6.2 |
April | 22.26 | 3.97 |
May | 23.29 | 13.43 |
June | 24.04 | 18.03 |
July | 24.27 | 19.67 |
August | 24.13 | 17.94 |
September | 23.68 | 12.29 |
October | 22.25 | 5.42 |
November | 21.75 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.73 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.27 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 21.90 | 3.97 |
May | 23.05 | 13.43 |
June | 24.02 | 18.03 |
July | 24.25 | 19.67 |
August | 24.06 | 17.94 |
September | 23.29 | 12.29 |
October | 21.86 | 5.42 |
November | 21.70 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.58 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.25 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.80 | -11.6 |
March | 21.90 | -6.2 |
April | 22.37 | 3.97 |
May | 23.41 | 13.43 |
June | 24.15 | 18.03 |
July | 24.31 | 19.67 |
August | 24.28 | 17.94 |
September | 23.71 | 12.29 |
October | 22.29 | 5.42 |
November | 21.88 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.80 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.31 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.70 | -6.2 |
April | 21.86 | 3.97 |
May | 23.00 | 13.43 |
June | 24.03 | 18.03 |
July | 24.26 | 19.67 |
August | 24.05 | 17.94 |
September | 23.20 | 12.29 |
October | 21.82 | 5.42 |
November | 21.70 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.56 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.26 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.70 | -6.2 |
April | 21.79 | 3.97 |
May | 22.80 | 13.43 |
June | 23.94 | 18.03 |
July | 24.18 | 19.67 |
August | 23.97 | 17.94 |
September | 23.21 | 12.29 |
October | 21.81 | 5.42 |
November | 21.70 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.52 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.18 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.70 | -6.2 |
April | 21.79 | 3.97 |
May | 22.79 | 13.43 |
June | 23.94 | 18.03 |
July | 24.18 | 19.67 |
August | 23.97 | 17.94 |
September | 23.20 | 12.29 |
October | 21.81 | 5.42 |
November | 21.70 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.52 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.18 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.77 | -11.6 |
March | 21.84 | -6.2 |
April | 22.19 | 3.97 |
May | 23.16 | 13.43 |
June | 24.02 | 18.03 |
July | 24.24 | 19.67 |
August | 24.12 | 17.94 |
September | 23.78 | 12.29 |
October | 22.30 | 5.42 |
November | 21.77 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.72 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.24 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.77 | -11.6 |
March | 21.85 | -6.2 |
April | 22.21 | 3.97 |
May | 23.20 | 13.43 |
June | 24.04 | 18.03 |
July | 24.25 | 19.67 |
August | 24.14 | 17.94 |
September | 23.81 | 12.29 |
October | 22.32 | 5.42 |
November | 21.78 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.74 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.25 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 12.90 | -16.9 |
February | 14.40 | -11.6 |
March | 15.77 | -6.2 |
April | 18.60 | 3.97 |
May | 21.76 | 13.43 |
June | 23.92 | 18.03 |
July | 24.65 | 19.67 |
August | 23.94 | 17.94 |
September | 22.15 | 12.29 |
October | 18.94 | 5.42 |
November | 16.57 | -2.0 |
December | 13.39 | -14.6 |
Annual Sum or Average | 18.94 | 3.36 |
Minimum of Months | 12.90 | -16.9 |
Maximum of Months | 24.65 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F2 SW APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.83 | -11.6 |
March | 22.04 | -6.2 |
April | 22.75 | 3.97 |
May | 24.05 | 13.43 |
June | 24.30 | 18.03 |
July | 24.36 | 19.67 |
August | 24.29 | 17.94 |
September | 24.06 | 12.29 |
October | 22.71 | 5.42 |
November | 21.81 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.97 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.36 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F2 NW APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.74 | -6.2 |
April | 22.18 | 3.97 |
May | 23.83 | 13.43 |
June | 24.28 | 18.03 |
July | 24.36 | 19.67 |
August | 24.24 | 17.94 |
September | 23.69 | 12.29 |
October | 22.11 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.78 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.36 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F2 SE APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.83 | -11.6 |
March | 22.07 | -6.2 |
April | 22.86 | 3.97 |
May | 24.10 | 13.43 |
June | 24.32 | 18.03 |
July | 24.38 | 19.67 |
August | 24.32 | 17.94 |
September | 24.10 | 12.29 |
October | 22.73 | 5.42 |
November | 21.83 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 23.00 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.38 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F2 NE APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.70 | -6.2 |
April | 22.11 | 3.97 |
May | 23.76 | 13.43 |
June | 24.28 | 18.03 |
July | 24.37 | 19.67 |
August | 24.24 | 17.94 |
September | 23.53 | 12.29 |
October | 22.00 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.74 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.37 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F2 N1 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 21.99 | 3.97 |
May | 23.65 | 13.43 |
June | 24.24 | 18.03 |
July | 24.34 | 19.67 |
August | 24.20 | 17.94 |
September | 23.61 | 12.29 |
October | 22.06 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.72 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.34 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F2 N2 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 21.99 | 3.97 |
May | 23.65 | 13.43 |
June | 24.24 | 18.03 |
July | 24.34 | 19.67 |
August | 24.20 | 17.94 |
September | 23.59 | 12.29 |
October | 22.05 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.72 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.34 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F2 S1 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -16.9 |
February | 21.88 | -11.6 |
March | 22.09 | -6.2 |
April | 22.81 | 3.97 |
May | 24.04 | 13.43 |
June | 24.28 | 18.03 |
July | 24.35 | 19.67 |
August | 24.28 | 17.94 |
September | 24.15 | 12.29 |
October | 22.87 | 5.42 |
November | 21.89 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 23.01 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.35 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F2 S2 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -16.9 |
February | 21.89 | -11.6 |
March | 22.09 | -6.2 |
April | 22.83 | 3.97 |
May | 24.05 | 13.43 |
June | 24.28 | 18.03 |
July | 24.35 | 19.67 |
August | 24.28 | 17.94 |
September | 24.15 | 12.29 |
October | 22.88 | 5.42 |
November | 21.90 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 23.02 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.35 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F2 CORRIDOR
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.56 | -16.9 |
February | 21.13 | -11.6 |
March | 21.79 | -6.2 |
April | 23.10 | 3.97 |
May | 25.18 | 13.43 |
June | 26.02 | 18.03 |
July | 26.33 | 19.67 |
August | 25.98 | 17.94 |
September | 25.13 | 12.29 |
October | 23.08 | 5.42 |
November | 21.62 | -2.0 |
December | 20.60 | -14.6 |
Annual Sum or Average | 23.39 | 3.36 |
Minimum of Months | 20.56 | -16.9 |
Maximum of Months | 26.33 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F3 SW APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -16.9 |
February | 21.84 | -11.6 |
March | 22.08 | -6.2 |
April | 22.85 | 3.97 |
May | 24.15 | 13.43 |
June | 24.31 | 18.03 |
July | 24.36 | 19.67 |
August | 24.29 | 17.94 |
September | 24.09 | 12.29 |
October | 22.82 | 5.42 |
November | 21.82 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 23.01 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.36 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F3 NW APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.75 | -6.2 |
April | 22.25 | 3.97 |
May | 23.98 | 13.43 |
June | 24.30 | 18.03 |
July | 24.36 | 19.67 |
August | 24.25 | 17.94 |
September | 23.74 | 12.29 |
October | 22.20 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.81 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.36 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F3 SE APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.82 | -11.6 |
March | 22.08 | -6.2 |
April | 22.90 | 3.97 |
May | 24.16 | 13.43 |
June | 24.32 | 18.03 |
July | 24.38 | 19.67 |
August | 24.31 | 17.94 |
September | 24.07 | 12.29 |
October | 22.77 | 5.42 |
November | 21.81 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 23.01 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.38 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F3 NE APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 22.19 | 3.97 |
May | 23.92 | 13.43 |
June | 24.31 | 18.03 |
July | 24.38 | 19.67 |
August | 24.25 | 17.94 |
September | 23.58 | 12.29 |
October | 22.07 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.77 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.38 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F3 N1 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 22.09 | 3.97 |
May | 23.86 | 13.43 |
June | 24.28 | 18.03 |
July | 24.34 | 19.67 |
August | 24.22 | 17.94 |
September | 23.70 | 12.29 |
October | 22.19 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.77 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.34 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F3 N2 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 22.08 | 3.97 |
May | 23.86 | 13.43 |
June | 24.28 | 18.03 |
July | 24.35 | 19.67 |
August | 24.22 | 17.94 |
September | 23.69 | 12.29 |
October | 22.17 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.77 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.35 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F3 S1 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.72 | -16.9 |
February | 21.91 | -11.6 |
March | 22.18 | -6.2 |
April | 22.97 | 3.97 |
May | 24.18 | 13.43 |
June | 24.30 | 18.03 |
July | 24.35 | 19.67 |
August | 24.29 | 17.94 |
September | 24.20 | 12.29 |
October | 23.02 | 5.42 |
November | 21.93 | -2.0 |
December | 21.71 | -14.6 |
Annual Sum or Average | 23.07 | 3.36 |
Minimum of Months | 21.71 | -16.9 |
Maximum of Months | 24.35 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F3 S2 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.72 | -16.9 |
February | 21.91 | -11.6 |
March | 22.18 | -6.2 |
April | 22.98 | 3.97 |
May | 24.19 | 13.43 |
June | 24.30 | 18.03 |
July | 24.35 | 19.67 |
August | 24.29 | 17.94 |
September | 24.20 | 12.29 |
October | 23.02 | 5.42 |
November | 21.93 | -2.0 |
December | 21.71 | -14.6 |
Annual Sum or Average | 23.07 | 3.36 |
Minimum of Months | 21.71 | -16.9 |
Maximum of Months | 24.35 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F3 CORRIDOR
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.24 | -16.9 |
February | 21.75 | -11.6 |
March | 22.38 | -6.2 |
April | 23.62 | 3.97 |
May | 25.71 | 13.43 |
June | 26.28 | 18.03 |
July | 26.51 | 19.67 |
August | 26.19 | 17.94 |
September | 25.43 | 12.29 |
October | 23.55 | 5.42 |
November | 22.08 | -2.0 |
December | 21.22 | -14.6 |
Annual Sum or Average | 23.84 | 3.36 |
Minimum of Months | 21.22 | -16.9 |
Maximum of Months | 26.51 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F4 SW APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -16.9 |
February | 21.83 | -11.6 |
March | 22.08 | -6.2 |
April | 22.85 | 3.97 |
May | 24.17 | 13.43 |
June | 24.31 | 18.03 |
July | 24.36 | 19.67 |
August | 24.30 | 17.94 |
September | 24.10 | 12.29 |
October | 22.84 | 5.42 |
November | 21.81 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 23.01 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.36 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F4 NW APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.75 | -6.2 |
April | 22.26 | 3.97 |
May | 24.00 | 13.43 |
June | 24.30 | 18.03 |
July | 24.36 | 19.67 |
August | 24.26 | 17.94 |
September | 23.75 | 12.29 |
October | 22.23 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.82 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.36 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F4 SE APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.81 | -11.6 |
March | 22.07 | -6.2 |
April | 22.88 | 3.97 |
May | 24.17 | 13.43 |
June | 24.32 | 18.03 |
July | 24.38 | 19.67 |
August | 24.31 | 17.94 |
September | 24.06 | 12.29 |
October | 22.78 | 5.42 |
November | 21.80 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 23.01 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.38 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F4 NE APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 22.19 | 3.97 |
May | 23.94 | 13.43 |
June | 24.31 | 18.03 |
July | 24.37 | 19.67 |
August | 24.26 | 17.94 |
September | 23.59 | 12.29 |
October | 22.10 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.78 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.37 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F4 N1 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 22.12 | 3.97 |
May | 23.91 | 13.43 |
June | 24.29 | 18.03 |
July | 24.34 | 19.67 |
August | 24.23 | 17.94 |
September | 23.74 | 12.29 |
October | 22.24 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.79 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.34 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F4 N2 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 22.11 | 3.97 |
May | 23.91 | 13.43 |
June | 24.29 | 18.03 |
July | 24.34 | 19.67 |
August | 24.23 | 17.94 |
September | 23.72 | 12.29 |
October | 22.22 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.79 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.34 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F4 S1 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.72 | -16.9 |
February | 21.91 | -11.6 |
March | 22.20 | -6.2 |
April | 23.00 | 3.97 |
May | 24.21 | 13.43 |
June | 24.30 | 18.03 |
July | 24.35 | 19.67 |
August | 24.30 | 17.94 |
September | 24.21 | 12.29 |
October | 23.07 | 5.42 |
November | 21.93 | -2.0 |
December | 21.71 | -14.6 |
Annual Sum or Average | 23.08 | 3.36 |
Minimum of Months | 21.71 | -16.9 |
Maximum of Months | 24.35 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F4 S2 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.72 | -16.9 |
February | 21.91 | -11.6 |
March | 22.20 | -6.2 |
April | 23.00 | 3.97 |
May | 24.21 | 13.43 |
June | 24.30 | 18.03 |
July | 24.35 | 19.67 |
August | 24.30 | 17.94 |
September | 24.21 | 12.29 |
October | 23.06 | 5.42 |
November | 21.93 | -2.0 |
December | 21.71 | -14.6 |
Annual Sum or Average | 23.08 | 3.36 |
Minimum of Months | 21.71 | -16.9 |
Maximum of Months | 24.35 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F4 CORRIDOR
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.42 | -16.9 |
February | 21.91 | -11.6 |
March | 22.55 | -6.2 |
April | 23.78 | 3.97 |
May | 25.89 | 13.43 |
June | 26.39 | 18.03 |
July | 26.61 | 19.67 |
August | 26.30 | 17.94 |
September | 25.55 | 12.29 |
October | 23.73 | 5.42 |
November | 22.22 | -2.0 |
December | 21.38 | -14.6 |
Annual Sum or Average | 23.99 | 3.36 |
Minimum of Months | 21.38 | -16.9 |
Maximum of Months | 26.61 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -16.9 |
February | 21.83 | -11.6 |
March | 22.08 | -6.2 |
April | 22.84 | 3.97 |
May | 24.17 | 13.43 |
June | 24.31 | 18.03 |
July | 24.36 | 19.67 |
August | 24.30 | 17.94 |
September | 24.09 | 12.29 |
October | 22.84 | 5.42 |
November | 21.81 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 23.01 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.36 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.75 | -6.2 |
April | 22.26 | 3.97 |
May | 24.01 | 13.43 |
June | 24.30 | 18.03 |
July | 24.35 | 19.67 |
August | 24.26 | 17.94 |
September | 23.74 | 12.29 |
October | 22.24 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.82 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.35 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.81 | -11.6 |
March | 22.07 | -6.2 |
April | 22.87 | 3.97 |
May | 24.17 | 13.43 |
June | 24.32 | 18.03 |
July | 24.38 | 19.67 |
August | 24.31 | 17.94 |
September | 24.06 | 12.29 |
October | 22.78 | 5.42 |
November | 21.80 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 23.00 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.38 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 22.19 | 3.97 |
May | 23.94 | 13.43 |
June | 24.31 | 18.03 |
July | 24.38 | 19.67 |
August | 24.26 | 17.94 |
September | 23.59 | 12.29 |
October | 22.11 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.78 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.38 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.72 | -6.2 |
April | 22.13 | 3.97 |
May | 23.93 | 13.43 |
June | 24.29 | 18.03 |
July | 24.34 | 19.67 |
August | 24.23 | 17.94 |
September | 23.75 | 12.29 |
October | 22.27 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.80 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.34 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 22.13 | 3.97 |
May | 23.93 | 13.43 |
June | 24.29 | 18.03 |
July | 24.34 | 19.67 |
August | 24.23 | 17.94 |
September | 23.73 | 12.29 |
October | 22.25 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.79 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.34 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.72 | -16.9 |
February | 21.90 | -11.6 |
March | 22.20 | -6.2 |
April | 23.00 | 3.97 |
May | 24.22 | 13.43 |
June | 24.29 | 18.03 |
July | 24.35 | 19.67 |
August | 24.30 | 17.94 |
September | 24.22 | 12.29 |
October | 23.08 | 5.42 |
November | 21.94 | -2.0 |
December | 21.71 | -14.6 |
Annual Sum or Average | 23.08 | 3.36 |
Minimum of Months | 21.71 | -16.9 |
Maximum of Months | 24.35 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.72 | -16.9 |
February | 21.90 | -11.6 |
March | 22.20 | -6.2 |
April | 23.01 | 3.97 |
May | 24.22 | 13.43 |
June | 24.29 | 18.03 |
July | 24.35 | 19.67 |
August | 24.30 | 17.94 |
September | 24.21 | 12.29 |
October | 23.08 | 5.42 |
November | 21.94 | -2.0 |
December | 21.71 | -14.6 |
Annual Sum or Average | 23.08 | 3.36 |
Minimum of Months | 21.71 | -16.9 |
Maximum of Months | 24.35 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.08 | -16.9 |
February | 22.56 | -11.6 |
March | 23.21 | -6.2 |
April | 24.41 | 3.97 |
May | 26.51 | 13.43 |
June | 27.00 | 18.03 |
July | 27.22 | 19.67 |
August | 26.91 | 17.94 |
September | 26.16 | 12.29 |
October | 24.38 | 5.42 |
November | 22.88 | -2.0 |
December | 22.05 | -14.6 |
Annual Sum or Average | 24.63 | 3.36 |
Minimum of Months | 22.05 | -16.9 |
Maximum of Months | 27.22 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F6 SW APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -16.9 |
February | 21.81 | -11.6 |
March | 22.04 | -6.2 |
April | 22.77 | 3.97 |
May | 24.12 | 13.43 |
June | 24.29 | 18.03 |
July | 24.35 | 19.67 |
August | 24.28 | 17.94 |
September | 24.02 | 12.29 |
October | 22.78 | 5.42 |
November | 21.79 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.98 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.35 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F6 NW APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.74 | -6.2 |
April | 22.20 | 3.97 |
May | 23.94 | 13.43 |
June | 24.28 | 18.03 |
July | 24.34 | 19.67 |
August | 24.24 | 17.94 |
September | 23.61 | 12.29 |
October | 22.17 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.78 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.34 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F6 SE APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.79 | -11.6 |
March | 22.04 | -6.2 |
April | 22.80 | 3.97 |
May | 24.12 | 13.43 |
June | 24.30 | 18.03 |
July | 24.37 | 19.67 |
August | 24.29 | 17.94 |
September | 23.98 | 12.29 |
October | 22.72 | 5.42 |
November | 21.78 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.97 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.37 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F6 NE APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.70 | -6.2 |
April | 22.13 | 3.97 |
May | 23.87 | 13.43 |
June | 24.28 | 18.03 |
July | 24.37 | 19.67 |
August | 24.23 | 17.94 |
September | 23.45 | 12.29 |
October | 22.05 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.75 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.37 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F6 N1 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 22.07 | 3.97 |
May | 23.86 | 13.43 |
June | 24.27 | 18.03 |
July | 24.33 | 19.67 |
August | 24.20 | 17.94 |
September | 23.63 | 12.29 |
October | 22.19 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.76 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.33 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F6 N2 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 22.07 | 3.97 |
May | 23.86 | 13.43 |
June | 24.27 | 18.03 |
July | 24.33 | 19.67 |
August | 24.20 | 17.94 |
September | 23.61 | 12.29 |
October | 22.17 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.76 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.33 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F6 S1 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -16.9 |
February | 21.88 | -11.6 |
March | 22.16 | -6.2 |
April | 22.92 | 3.97 |
May | 24.18 | 13.43 |
June | 24.27 | 18.03 |
July | 24.34 | 19.67 |
August | 24.28 | 17.94 |
September | 24.16 | 12.29 |
October | 23.01 | 5.42 |
November | 21.90 | -2.0 |
December | 21.71 | -14.6 |
Annual Sum or Average | 23.05 | 3.36 |
Minimum of Months | 21.71 | -16.9 |
Maximum of Months | 24.34 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F6 S2 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -16.9 |
February | 21.88 | -11.6 |
March | 22.16 | -6.2 |
April | 22.93 | 3.97 |
May | 24.18 | 13.43 |
June | 24.27 | 18.03 |
July | 24.34 | 19.67 |
August | 24.28 | 17.94 |
September | 24.16 | 12.29 |
October | 23.01 | 5.42 |
November | 21.90 | -2.0 |
December | 21.71 | -14.6 |
Annual Sum or Average | 23.05 | 3.36 |
Minimum of Months | 21.71 | -16.9 |
Maximum of Months | 24.34 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F6 CORRIDOR
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.38 | -16.9 |
February | 21.86 | -11.6 |
March | 22.51 | -6.2 |
April | 23.70 | 3.97 |
May | 25.84 | 13.43 |
June | 26.36 | 18.03 |
July | 26.60 | 19.67 |
August | 26.27 | 17.94 |
September | 25.45 | 12.29 |
October | 23.67 | 5.42 |
November | 22.17 | -2.0 |
December | 21.34 | -14.6 |
Annual Sum or Average | 23.94 | 3.36 |
Minimum of Months | 21.34 | -16.9 |
Maximum of Months | 26.60 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F7 SW APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -16.9 |
February | 21.80 | -11.6 |
March | 22.02 | -6.2 |
April | 22.72 | 3.97 |
May | 24.09 | 13.43 |
June | 24.27 | 18.03 |
July | 24.35 | 19.67 |
August | 24.27 | 17.94 |
September | 23.96 | 12.29 |
October | 22.72 | 5.42 |
November | 21.78 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.96 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.35 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F7 NW APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.73 | -6.2 |
April | 22.16 | 3.97 |
May | 23.89 | 13.43 |
June | 24.26 | 18.03 |
July | 24.34 | 19.67 |
August | 24.22 | 17.94 |
September | 23.51 | 12.29 |
October | 22.12 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.76 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.34 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F7 SE APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.78 | -11.6 |
March | 22.01 | -6.2 |
April | 22.74 | 3.97 |
May | 24.09 | 13.43 |
June | 24.28 | 18.03 |
July | 24.37 | 19.67 |
August | 24.28 | 17.94 |
September | 23.92 | 12.29 |
October | 22.67 | 5.42 |
November | 21.77 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.95 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.37 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F7 NE APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.70 | -6.2 |
April | 22.09 | 3.97 |
May | 23.81 | 13.43 |
June | 24.27 | 18.03 |
July | 24.36 | 19.67 |
August | 24.21 | 17.94 |
September | 23.34 | 12.29 |
October | 22.00 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.72 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.36 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F7 N1 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 22.04 | 3.97 |
May | 23.80 | 13.43 |
June | 24.25 | 18.03 |
July | 24.32 | 19.67 |
August | 24.18 | 17.94 |
September | 23.52 | 12.29 |
October | 22.13 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.74 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.32 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F7 N2 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 22.03 | 3.97 |
May | 23.80 | 13.43 |
June | 24.25 | 18.03 |
July | 24.32 | 19.67 |
August | 24.18 | 17.94 |
September | 23.50 | 12.29 |
October | 22.12 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.73 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.32 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F7 S1 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -16.9 |
February | 21.86 | -11.6 |
March | 22.12 | -6.2 |
April | 22.87 | 3.97 |
May | 24.15 | 13.43 |
June | 24.26 | 18.03 |
July | 24.34 | 19.67 |
August | 24.27 | 17.94 |
September | 24.11 | 12.29 |
October | 22.96 | 5.42 |
November | 21.88 | -2.0 |
December | 21.71 | -14.6 |
Annual Sum or Average | 23.03 | 3.36 |
Minimum of Months | 21.71 | -16.9 |
Maximum of Months | 24.34 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F7 S2 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -16.9 |
February | 21.86 | -11.6 |
March | 22.12 | -6.2 |
April | 22.87 | 3.97 |
May | 24.15 | 13.43 |
June | 24.26 | 18.03 |
July | 24.34 | 19.67 |
August | 24.27 | 17.94 |
September | 24.11 | 12.29 |
October | 22.95 | 5.42 |
November | 21.88 | -2.0 |
December | 21.71 | -14.6 |
Annual Sum or Average | 23.03 | 3.36 |
Minimum of Months | 21.71 | -16.9 |
Maximum of Months | 24.34 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F7 CORRIDOR
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.23 | -16.9 |
February | 21.70 | -11.6 |
March | 22.35 | -6.2 |
April | 23.53 | 3.97 |
May | 25.70 | 13.43 |
June | 26.25 | 18.03 |
July | 26.50 | 19.67 |
August | 26.16 | 17.94 |
September | 25.27 | 12.29 |
October | 23.50 | 5.42 |
November | 22.02 | -2.0 |
December | 21.19 | -14.6 |
Annual Sum or Average | 23.80 | 3.36 |
Minimum of Months | 21.19 | -16.9 |
Maximum of Months | 26.50 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F8 SW APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -16.9 |
February | 21.79 | -11.6 |
March | 22.00 | -6.2 |
April | 22.67 | 3.97 |
May | 24.05 | 13.43 |
June | 24.26 | 18.03 |
July | 24.35 | 19.67 |
August | 24.25 | 17.94 |
September | 23.89 | 12.29 |
October | 22.67 | 5.42 |
November | 21.77 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.93 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.35 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F8 NW APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.73 | -6.2 |
April | 22.12 | 3.97 |
May | 23.84 | 13.43 |
June | 24.24 | 18.03 |
July | 24.33 | 19.67 |
August | 24.20 | 17.94 |
September | 23.41 | 12.29 |
October | 22.07 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.74 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.33 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F8 SE APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.77 | -11.6 |
March | 21.99 | -6.2 |
April | 22.70 | 3.97 |
May | 24.05 | 13.43 |
June | 24.27 | 18.03 |
July | 24.37 | 19.67 |
August | 24.27 | 17.94 |
September | 23.85 | 12.29 |
October | 22.62 | 5.42 |
November | 21.76 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.93 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.37 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F8 NE APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.70 | -6.2 |
April | 22.06 | 3.97 |
May | 23.76 | 13.43 |
June | 24.25 | 18.03 |
July | 24.36 | 19.67 |
August | 24.19 | 17.94 |
September | 23.24 | 12.29 |
October | 21.96 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.70 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.36 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F8 N1 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 22.01 | 3.97 |
May | 23.75 | 13.43 |
June | 24.23 | 18.03 |
July | 24.31 | 19.67 |
August | 24.16 | 17.94 |
September | 23.41 | 12.29 |
October | 22.08 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.71 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.31 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F8 N2 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 22.00 | 3.97 |
May | 23.75 | 13.43 |
June | 24.23 | 18.03 |
July | 24.32 | 19.67 |
August | 24.16 | 17.94 |
September | 23.39 | 12.29 |
October | 22.06 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.71 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.32 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F8 S1 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -16.9 |
February | 21.85 | -11.6 |
March | 22.09 | -6.2 |
April | 22.81 | 3.97 |
May | 24.11 | 13.43 |
June | 24.25 | 18.03 |
July | 24.33 | 19.67 |
August | 24.25 | 17.94 |
September | 24.06 | 12.29 |
October | 22.90 | 5.42 |
November | 21.86 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 23.00 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.33 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F8 S2 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -16.9 |
February | 21.85 | -11.6 |
March | 22.09 | -6.2 |
April | 22.81 | 3.97 |
May | 24.12 | 13.43 |
June | 24.25 | 18.03 |
July | 24.33 | 19.67 |
August | 24.26 | 17.94 |
September | 24.05 | 12.29 |
October | 22.89 | 5.42 |
November | 21.86 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 23.00 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.33 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F8 CORRIDOR
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.13 | -16.9 |
February | 21.60 | -11.6 |
March | 22.26 | -6.2 |
April | 23.43 | 3.97 |
May | 25.63 | 13.43 |
June | 26.21 | 18.03 |
July | 26.49 | 19.67 |
August | 26.12 | 17.94 |
September | 25.15 | 12.29 |
October | 23.38 | 5.42 |
November | 21.93 | -2.0 |
December | 21.10 | -14.6 |
Annual Sum or Average | 23.71 | 3.36 |
Minimum of Months | 21.10 | -16.9 |
Maximum of Months | 26.49 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F9 SW APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.78 | -11.6 |
March | 21.97 | -6.2 |
April | 22.61 | 3.97 |
May | 23.99 | 13.43 |
June | 24.23 | 18.03 |
July | 24.34 | 19.67 |
August | 24.23 | 17.94 |
September | 23.78 | 12.29 |
October | 22.58 | 5.42 |
November | 21.76 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.90 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.34 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F9 NW APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.73 | -6.2 |
April | 22.10 | 3.97 |
May | 23.77 | 13.43 |
June | 24.22 | 18.03 |
July | 24.33 | 19.67 |
August | 24.17 | 17.94 |
September | 23.28 | 12.29 |
October | 22.02 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.71 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.33 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F9 SE APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.76 | -11.6 |
March | 21.96 | -6.2 |
April | 22.63 | 3.97 |
May | 23.99 | 13.43 |
June | 24.25 | 18.03 |
July | 24.36 | 19.67 |
August | 24.24 | 17.94 |
September | 23.74 | 12.29 |
October | 22.53 | 5.42 |
November | 21.75 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.89 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.36 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F9 NE APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.70 | -6.2 |
April | 22.03 | 3.97 |
May | 23.69 | 13.43 |
June | 24.22 | 18.03 |
July | 24.35 | 19.67 |
August | 24.16 | 17.94 |
September | 23.11 | 12.29 |
October | 21.92 | 5.42 |
November | 21.70 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.67 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.35 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F9 N1 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.70 | -6.2 |
April | 21.99 | 3.97 |
May | 23.69 | 13.43 |
June | 24.20 | 18.03 |
July | 24.31 | 19.67 |
August | 24.13 | 17.94 |
September | 23.26 | 12.29 |
October | 22.01 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.68 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.31 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F9 N2 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.70 | -6.2 |
April | 21.98 | 3.97 |
May | 23.68 | 13.43 |
June | 24.20 | 18.03 |
July | 24.31 | 19.67 |
August | 24.13 | 17.94 |
September | 23.24 | 12.29 |
October | 22.00 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.68 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.31 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F9 S1 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -16.9 |
February | 21.83 | -11.6 |
March | 22.04 | -6.2 |
April | 22.72 | 3.97 |
May | 24.06 | 13.43 |
June | 24.23 | 18.03 |
July | 24.33 | 19.67 |
August | 24.24 | 17.94 |
September | 23.95 | 12.29 |
October | 22.78 | 5.42 |
November | 21.82 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.96 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.33 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F9 S2 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -16.9 |
February | 21.83 | -11.6 |
March | 22.04 | -6.2 |
April | 22.73 | 3.97 |
May | 24.06 | 13.43 |
June | 24.23 | 18.03 |
July | 24.33 | 19.67 |
August | 24.24 | 17.94 |
September | 23.95 | 12.29 |
October | 22.77 | 5.42 |
November | 21.83 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.96 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.33 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: F9 CORRIDOR
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.85 | -16.9 |
February | 21.35 | -11.6 |
March | 22.05 | -6.2 |
April | 23.27 | 3.97 |
May | 25.55 | 13.43 |
June | 26.20 | 18.03 |
July | 26.52 | 19.67 |
August | 26.10 | 17.94 |
September | 24.98 | 12.29 |
October | 23.17 | 5.42 |
November | 21.73 | -2.0 |
December | 20.84 | -14.6 |
Annual Sum or Average | 23.56 | 3.36 |
Minimum of Months | 20.84 | -16.9 |
Maximum of Months | 26.52 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -16.9 |
February | 21.81 | -11.6 |
March | 21.99 | -6.2 |
April | 22.48 | 3.97 |
May | 23.69 | 13.43 |
June | 24.07 | 18.03 |
July | 24.27 | 19.67 |
August | 24.10 | 17.94 |
September | 23.45 | 12.29 |
October | 22.35 | 5.42 |
November | 21.78 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.79 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.27 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.76 | -6.2 |
April | 22.12 | 3.97 |
May | 23.53 | 13.43 |
June | 24.04 | 18.03 |
July | 24.24 | 19.67 |
August | 24.02 | 17.94 |
September | 23.01 | 12.29 |
October | 21.98 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.63 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.24 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.79 | -11.6 |
March | 21.98 | -6.2 |
April | 22.49 | 3.97 |
May | 23.71 | 13.43 |
June | 24.09 | 18.03 |
July | 24.29 | 19.67 |
August | 24.11 | 17.94 |
September | 23.41 | 12.29 |
October | 22.32 | 5.42 |
November | 21.77 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.79 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.29 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.70 | -6.2 |
April | 22.06 | 3.97 |
May | 23.49 | 13.43 |
June | 24.03 | 18.03 |
July | 24.24 | 19.67 |
August | 23.97 | 17.94 |
September | 22.88 | 12.29 |
October | 21.90 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.60 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.24 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 21.99 | 3.97 |
May | 23.46 | 13.43 |
June | 24.03 | 18.03 |
July | 24.21 | 19.67 |
August | 23.97 | 17.94 |
September | 22.92 | 12.29 |
October | 21.92 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.59 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.21 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -16.9 |
February | 21.70 | -11.6 |
March | 21.71 | -6.2 |
April | 21.99 | 3.97 |
May | 23.46 | 13.43 |
June | 24.03 | 18.03 |
July | 24.22 | 19.67 |
August | 23.97 | 17.94 |
September | 22.91 | 12.29 |
October | 21.92 | 5.42 |
November | 21.71 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.59 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.22 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -16.9 |
February | 21.84 | -11.6 |
March | 22.02 | -6.2 |
April | 22.55 | 3.97 |
May | 23.77 | 13.43 |
June | 24.09 | 18.03 |
July | 24.27 | 19.67 |
August | 24.13 | 17.94 |
September | 23.61 | 12.29 |
October | 22.48 | 5.42 |
November | 21.82 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.84 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.27 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -16.9 |
February | 21.84 | -11.6 |
March | 22.02 | -6.2 |
April | 22.55 | 3.97 |
May | 23.78 | 13.43 |
June | 24.09 | 18.03 |
July | 24.27 | 19.67 |
August | 24.13 | 17.94 |
September | 23.61 | 12.29 |
October | 22.48 | 5.42 |
November | 21.82 | -2.0 |
December | 21.70 | -14.6 |
Annual Sum or Average | 22.84 | 3.36 |
Minimum of Months | 21.70 | -16.9 |
Maximum of Months | 24.27 | 19.67 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2018-10-19 09:40:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.07 | -16.9 |
February | 20.79 | -11.6 |
March | 21.72 | -6.2 |
April | 23.27 | 3.97 |
May | 25.86 | 13.43 |
June | 26.72 | 18.03 |
July | 27.11 | 19.67 |
August | 26.57 | 17.94 |
September | 25.10 | 12.29 |
October | 23.05 | 5.42 |
November | 21.44 | -2.0 |
December | 20.14 | -14.6 |
Annual Sum or Average | 23.50 | 3.36 |
Minimum of Months | 20.07 | -16.9 |
Maximum of Months | 27.11 | 19.67 |
Report: COMPONENTS OF PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2018-10-19 09:40:12
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W] | |
January | 0.311826E+12 | 186608.339 | 04-JAN-20:00 | 25049.151 | 49704.829 | 18696.254 | 79904.963 | 0.000 | 10720.100 | 1587.470 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
February | 0.256930E+12 | 156627.563 | 13-FEB-19:00 | 25049.151 | 51564.864 | 18696.254 | 47995.109 | 0.000 | 10720.100 | 1587.470 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
March | 0.254299E+12 | 139673.064 | 04-MAR-18:00 | 22204.399 | 56867.515 | 18696.254 | 28451.436 | 0.000 | 10720.100 | 1587.470 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
April | 0.216442E+12 | 156329.412 | 23-APR-16:15 | 18221.747 | 56867.515 | 18696.254 | 0.000 | 57772.256 | 0.000 | 1587.470 | 2038.750 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
May | 0.227740E+12 | 162582.087 | 25-MAY-17:00 | 22204.399 | 56867.515 | 18696.254 | 0.000 | 59814.575 | 0.000 | 1587.470 | 2265.984 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
June | 0.247143E+12 | 174163.671 | 29-JUN-17:30 | 22204.399 | 56867.515 | 18696.254 | 0.000 | 70828.270 | 0.000 | 1587.470 | 2833.873 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
July | 0.277369E+12 | 172290.413 | 13-JUL-17:15 | 22204.399 | 56867.515 | 18696.254 | 0.000 | 69267.302 | 0.000 | 1587.470 | 2521.836 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.252484E+12 | 171852.899 | 08-AUG-17:15 | 22204.399 | 56867.515 | 18696.254 | 0.000 | 68620.491 | 0.000 | 1587.470 | 2731.134 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.209666E+12 | 160452.888 | 01-SEP-16:15 | 18221.747 | 56933.809 | 18696.254 | 0.000 | 61655.035 | 0.000 | 1587.470 | 2210.268 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
October | 0.221931E+12 | 129025.499 | 31-OCT-17:15 | 22204.399 | 56867.515 | 18696.254 | 17804.124 | 0.000 | 10720.100 | 1587.470 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
November | 0.247973E+12 | 145448.980 | 23-NOV-18:00 | 22204.399 | 56867.515 | 18696.254 | 34227.352 | 0.000 | 10720.100 | 1587.470 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
December | 0.308281E+12 | 177676.446 | 18-DEC-17:15 | 18221.747 | 56933.809 | 18696.254 | 70368.761 | 0.000 | 10720.100 | 1587.470 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.303208E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||||
Minimum of Months | 0.209666E+12 | 129025.499 | 18221.747 | 49704.829 | 18696.254 | 0.000 | 0.000 | 0.000 | 1587.470 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.311826E+12 | 186608.339 | 25049.151 | 56933.809 | 18696.254 | 79904.963 | 70828.270 | 10720.100 | 1587.470 | 2833.873 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: COMPONENTS OF PEAK GAS DEMAND
For: Meter
Timestamp: 2018-10-19 09:40:12
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC [Invalid/Undefined] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT {AT MAX/MIN} [W] | WATERSYSTEMS:GAS {AT MAX/MIN} [W] | WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.539988E+12 | 357683.272 | 04-JAN-08:30 | 0.000 | 0.000 | 0.000 | 357683.272 | 92291.396 | 92291.396 | 265391.876 |
February | 0.402992E+12 | 334290.388 | 13-FEB-06:00 | 0.000 | 0.000 | 0.000 | 334290.388 | 92708.536 | 92708.536 | 241581.852 |
March | 0.322274E+12 | 299065.679 | 15-MAR-05:30 | 0.000 | 0.000 | 0.000 | 299065.679 | 88498.011 | 88498.011 | 210567.669 |
April | 0.181476E+12 | 203538.470 | 04-APR-06:30 | 0.000 | 0.000 | 0.000 | 203538.470 | 94855.424 | 94855.424 | 108683.045 |
May | 0.119816E+12 | 100555.432 | 01-MAY-05:45 | 0.000 | 0.000 | 0.000 | 100555.432 | 89023.667 | 89023.667 | 11531.765 |
June | 0.108839E+12 | 90147.126 | 01-JUN-06:00 | 0.000 | 0.000 | 0.000 | 90147.126 | 90147.126 | 90147.126 | 0.000 |
July | 0.106654E+12 | 87527.353 | 02-JUL-06:45 | 0.000 | 0.000 | 0.000 | 87527.353 | 87527.353 | 87527.353 | 0.000 |
August | 0.103535E+12 | 85836.667 | 03-AUG-06:45 | 0.000 | 0.000 | 0.000 | 85836.667 | 85836.667 | 85836.667 | 0.000 |
September | 0.100766E+12 | 86259.523 | 30-SEP-06:45 | 0.000 | 0.000 | 0.000 | 86259.523 | 86259.523 | 86259.523 | 0.000 |
October | 0.150840E+12 | 194024.409 | 30-OCT-06:00 | 0.000 | 0.000 | 0.000 | 194024.409 | 88223.188 | 88223.188 | 105801.221 |
November | 0.289605E+12 | 279978.400 | 25-NOV-06:45 | 0.000 | 0.000 | 0.000 | 279978.400 | 86872.274 | 86872.274 | 193106.125 |
December | 0.519718E+12 | 357114.842 | 24-DEC-08:15 | 0.000 | 0.000 | 0.000 | 357114.842 | 92291.630 | 92291.630 | 264823.212 |
Annual Sum or Average | 0.294650E+13 | 0.000 | 0.000 | 0.000 | ||||||
Minimum of Months | 0.100766E+12 | 85836.667 | 0.000 | 0.000 | 0.000 | 85836.667 | 85836.667 | 85836.667 | 0.000 | |
Maximum of Months | 0.539988E+12 | 357683.272 | 0.000 | 0.000 | 0.000 | 357683.272 | 94855.424 | 94855.424 | 265391.876 |