Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:37
Tabular Output Report in Format: HTML
Building: High-Rise Apartment
Environment: Tucson-Davis Monthan AFB AZ USA TMY3 WMO#=722745
Simulation Timestamp: 2018-10-19 09:40:11
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:11
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 4407.35 | 562.42 | 624.28 |
Net Site Energy | 4407.35 | 562.42 | 624.28 |
Total Source Energy | 12079.41 | 1541.43 | 1710.99 |
Net Source Energy | 12079.41 | 1541.43 | 1710.99 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 7836.48 |
Net Conditioned Building Area | 7059.89 |
Unconditioned Building Area | 776.58 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 4.73 | 2.88 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 908.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 416.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 168.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1131.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 770.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 52.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 33.55 | 0.00 | 0.00 | 0.00 | 0.00 | 3290.19 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 899.03 | 0.00 | 0.00 | 0.00 | 4778.51 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 3505.44 | 901.91 | 0.00 | 0.00 | 0.00 | 8068.70 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Boiler | 0.00 | 2.88 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Other | 4.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 908.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 348.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 67.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 168.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 1131.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 770.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 52.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 33.55 | 0.00 | 0.00 | 0.00 | 0.00 | 3290.19 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 899.03 | 0.00 | 0.00 | 0.00 | 0.00 |
sub cat | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4778.51 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 82.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 250.51 | 127.75 | 0.00 | 0.00 | 0.00 | 1.14 |
Other | 160.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 496.53 | 127.75 | 0.00 | 0.00 | 0.00 | 1.14 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 74.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 225.69 | 115.09 | 0.00 | 0.00 | 0.00 | 1.03 |
Other | 144.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 447.32 | 115.09 | 0.00 | 0.00 | 0.00 | 1.03 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 3505.44 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 3505.44 | 100.00 |
Total On-Site and Utility Electric Sources | 3505.44 | 100.00 |
Total Electricity End Uses | 3505.44 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 8068.70 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 8068.70 | 100.00 |
Total Water End Uses | 8068.70 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 10.75 |
Time Setpoint Not Met During Occupied Cooling | 640.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 627.50 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |COMPONENTS OF PEAK ELECTRICAL DEMAND
| Meter |COMPONENTS OF PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:11
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 09:37 |
RunPeriod | Tucson-Davis Monthan AFB AZ USA TMY3 WMO#=722745 |
Weather File | Tucson-Davis Monthan AFB AZ USA TMY3 WMO#=722745 |
Latitude [deg] | 32.17 |
Longitude [deg] | -110.9 |
Elevation [m] | 809.00 |
Time Zone | -7.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 3855.02 | 1411.96 | 515.55 | 1411.96 | 515.55 |
Window Opening Area [m2] | 1150.39 | 423.59 | 152.73 | 423.59 | 150.48 |
Window-Wall Ratio [%] | 29.84 | 30.00 | 29.62 | 30.00 | 29.19 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 3752.84 | 1411.96 | 464.46 | 1411.96 | 464.46 |
Window Opening Area [m2] | 1125.85 | 423.59 | 139.34 | 423.59 | 139.34 |
Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 23.8959 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 4.47 | 8.5250 | 0.0000 | |
F2 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F2 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F2 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F2 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F2 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F2 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F2 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F2 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F2 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 8.5250 | 0.0000 | |
F3 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F3 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F3 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F3 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F3 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F3 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F3 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F3 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F3 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 8.5250 | 0.0000 | |
F4 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F4 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F4 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F4 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F4 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F4 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F4 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F4 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F4 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 8.5250 | 0.0000 | |
M SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 17.0500 | 0.0000 | |
F6 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F6 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F6 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F6 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F6 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F6 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F6 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F6 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F6 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 8.5250 | 0.0000 | |
F7 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F7 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F7 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F7 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F7 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F7 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F7 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F7 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F7 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 8.5250 | 0.0000 | |
F8 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F8 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F8 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F8 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F8 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F8 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F8 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F8 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F8 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 8.5250 | 0.0000 | |
F9 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F9 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F9 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F9 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
F9 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F9 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F9 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F9 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
F9 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 8.5250 | 0.0000 | |
T SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 14.4236 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 14.4236 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 8.5250 | 263.6661 | |
Total | 7836.48 | 23884.04 | 3855.02 | 1150.39 | 14.0302 | 39.48 | 8.6219 | |||
Conditioned Total | 7059.89 | 21517.16 | 3752.84 | 1125.85 | 14.5420 | 35.57 | 6.6700 | |||
Unconditioned Total | 776.58 | 2366.87 | 102.18 | 24.54 | 9.3775 | 26.3666 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:11
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 16-JUN-19:30 | 17-DEC-07:30 | - | - | - | 28-JUN-17:30 |
Heating | 0.00 | 27346.18 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 71861.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 25049.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 10720.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 49704.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 24420.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 1697.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 2260.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 78424.24 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 186660.91 | 105770.42 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | Boiler | 0.00 | 27346.18 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 71861.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 20603.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 4445.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 10720.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 49704.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 24420.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 1697.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 2260.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 78424.24 | 0.00 | 0.00 | 0.00 | 0.00 |
sub cat | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:11
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 14.98 | 3.12 | 0.00 | 0.00 | 0.00 |
Cooling | 2875.83 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1318.78 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 533.68 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 3582.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 2439.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 165.06 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 106.25 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 974.55 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 11101.74 | 977.67 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 2.12 | 0.44 | 0.00 | 0.00 | 0.00 |
Cooling | 407.35 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 186.80 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 75.59 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 507.40 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 345.48 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 23.38 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 15.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 138.04 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1572.51 | 138.48 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 2.12 | 0.44 | 0.00 | 0.00 | 0.00 |
Cooling | 407.35 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 186.80 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 75.59 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 507.40 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 345.48 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 23.38 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 15.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 138.04 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1572.51 | 138.48 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:11
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 0.50 | 0.00 | 0.50 | Wetbulb [C] | 2.10 | 140.00 |
TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 40.80 | 13.30 | 18.50 | Wetbulb [C] | 4.80 | 310.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:11
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 270.00 | 180.00 | |
F2 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F2 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F2 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F2 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F2 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F2 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F3 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F3 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F3 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F3 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F3 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F3 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F4 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F4 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F4 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F4 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F4 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F4 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F6 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F6 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F6 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F6 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F6 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F6 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F7 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F7 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F7 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F7 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F7 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F7 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F8 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F8 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F8 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F8 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F8 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F8 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F9 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F9 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F9 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F9 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F9 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F9 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.55 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.55 | 0.269 | 0.283 | 77.66 | 0.00 | 0.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
GWINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | G WWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_0.72_SHGC_0.25 | 3.36 | 0.00 | 0.00 | 3.36 | 3.36 | 4.600 | 0.293 | 0.130 | No | G EWALL C | 90.00 | 90.00 | E | ||
F2WINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F2 WWALL SWA | 270.00 | 90.00 | W | ||
F2WINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 SWALL SWA | 180.00 | 90.00 | S | ||
F2WINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 NWALL NWA | 0.00 | 90.00 | N | ||
F2WINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F2 WWALL NWA | 270.00 | 90.00 | W | ||
F2WINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F2 EWALL SEA | 90.00 | 90.00 | E | ||
F2WINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 SWALL SEA | 180.00 | 90.00 | S | ||
F2WINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 NWALL NEA | 0.00 | 90.00 | N | ||
F2WINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F2 EWALL NEA | 90.00 | 90.00 | E | ||
F2WINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 NWALL N1A | 0.00 | 90.00 | N | ||
F2WINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 NWALL N2A | 0.00 | 90.00 | N | ||
F2WINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 SWALL S1A | 180.00 | 90.00 | S | ||
F2WINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 SWALL S2A | 180.00 | 90.00 | S | ||
F2WINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F2 WWALL C | 270.00 | 90.00 | W | ||
F2WINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F2 EWALL C | 90.00 | 90.00 | E | ||
F3WINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F3 WWALL SWA | 270.00 | 90.00 | W | ||
F3WINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 SWALL SWA | 180.00 | 90.00 | S | ||
F3WINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 NWALL NWA | 0.00 | 90.00 | N | ||
F3WINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F3 WWALL NWA | 270.00 | 90.00 | W | ||
F3WINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F3 EWALL SEA | 90.00 | 90.00 | E | ||
F3WINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 SWALL SEA | 180.00 | 90.00 | S | ||
F3WINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 NWALL NEA | 0.00 | 90.00 | N | ||
F3WINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F3 EWALL NEA | 90.00 | 90.00 | E | ||
F3WINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 NWALL N1A | 0.00 | 90.00 | N | ||
F3WINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 NWALL N2A | 0.00 | 90.00 | N | ||
F3WINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 SWALL S1A | 180.00 | 90.00 | S | ||
F3WINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 SWALL S2A | 180.00 | 90.00 | S | ||
F3WINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F3 WWALL C | 270.00 | 90.00 | W | ||
F3WINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F3 EWALL C | 90.00 | 90.00 | E | ||
F4WINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F4 WWALL SWA | 270.00 | 90.00 | W | ||
F4WINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 SWALL SWA | 180.00 | 90.00 | S | ||
F4WINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 NWALL NWA | 0.00 | 90.00 | N | ||
F4WINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F4 WWALL NWA | 270.00 | 90.00 | W | ||
F4WINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F4 EWALL SEA | 90.00 | 90.00 | E | ||
F4WINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 SWALL SEA | 180.00 | 90.00 | S | ||
F4WINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 NWALL NEA | 0.00 | 90.00 | N | ||
F4WINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F4 EWALL NEA | 90.00 | 90.00 | E | ||
F4WINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 NWALL N1A | 0.00 | 90.00 | N | ||
F4WINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 NWALL N2A | 0.00 | 90.00 | N | ||
F4WINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 SWALL S1A | 180.00 | 90.00 | S | ||
F4WINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 SWALL S2A | 180.00 | 90.00 | S | ||
F4WINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F4 WWALL C | 270.00 | 90.00 | W | ||
F4WINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F4 EWALL C | 90.00 | 90.00 | E | ||
MWINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | M WWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | M EWALL C | 90.00 | 90.00 | E | ||
F6WINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F6 WWALL SWA | 270.00 | 90.00 | W | ||
F6WINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 SWALL SWA | 180.00 | 90.00 | S | ||
F6WINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 NWALL NWA | 0.00 | 90.00 | N | ||
F6WINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F6 WWALL NWA | 270.00 | 90.00 | W | ||
F6WINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F6 EWALL SEA | 90.00 | 90.00 | E | ||
F6WINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 SWALL SEA | 180.00 | 90.00 | S | ||
F6WINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 NWALL NEA | 0.00 | 90.00 | N | ||
F6WINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F6 EWALL NEA | 90.00 | 90.00 | E | ||
F6WINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 NWALL N1A | 0.00 | 90.00 | N | ||
F6WINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 NWALL N2A | 0.00 | 90.00 | N | ||
F6WINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 SWALL S1A | 180.00 | 90.00 | S | ||
F6WINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 SWALL S2A | 180.00 | 90.00 | S | ||
F6WINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F6 WWALL C | 270.00 | 90.00 | W | ||
F6WINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F6 EWALL C | 90.00 | 90.00 | E | ||
F7WINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F7 WWALL SWA | 270.00 | 90.00 | W | ||
F7WINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 SWALL SWA | 180.00 | 90.00 | S | ||
F7WINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 NWALL NWA | 0.00 | 90.00 | N | ||
F7WINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F7 WWALL NWA | 270.00 | 90.00 | W | ||
F7WINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F7 EWALL SEA | 90.00 | 90.00 | E | ||
F7WINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 SWALL SEA | 180.00 | 90.00 | S | ||
F7WINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 NWALL NEA | 0.00 | 90.00 | N | ||
F7WINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F7 EWALL NEA | 90.00 | 90.00 | E | ||
F7WINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 NWALL N1A | 0.00 | 90.00 | N | ||
F7WINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 NWALL N2A | 0.00 | 90.00 | N | ||
F7WINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 SWALL S1A | 180.00 | 90.00 | S | ||
F7WINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 SWALL S2A | 180.00 | 90.00 | S | ||
F7WINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F7 WWALL C | 270.00 | 90.00 | W | ||
F7WINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F7 EWALL C | 90.00 | 90.00 | E | ||
F8WINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F8 WWALL SWA | 270.00 | 90.00 | W | ||
F8WINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 SWALL SWA | 180.00 | 90.00 | S | ||
F8WINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 NWALL NWA | 0.00 | 90.00 | N | ||
F8WINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F8 WWALL NWA | 270.00 | 90.00 | W | ||
F8WINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F8 EWALL SEA | 90.00 | 90.00 | E | ||
F8WINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 SWALL SEA | 180.00 | 90.00 | S | ||
F8WINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 NWALL NEA | 0.00 | 90.00 | N | ||
F8WINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F8 EWALL NEA | 90.00 | 90.00 | E | ||
F8WINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 NWALL N1A | 0.00 | 90.00 | N | ||
F8WINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 NWALL N2A | 0.00 | 90.00 | N | ||
F8WINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 SWALL S1A | 180.00 | 90.00 | S | ||
F8WINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 SWALL S2A | 180.00 | 90.00 | S | ||
F8WINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F8 WWALL C | 270.00 | 90.00 | W | ||
F8WINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F8 EWALL C | 90.00 | 90.00 | E | ||
F9WINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F9 WWALL SWA | 270.00 | 90.00 | W | ||
F9WINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 SWALL SWA | 180.00 | 90.00 | S | ||
F9WINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 NWALL NWA | 0.00 | 90.00 | N | ||
F9WINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F9 WWALL NWA | 270.00 | 90.00 | W | ||
F9WINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F9 EWALL SEA | 90.00 | 90.00 | E | ||
F9WINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 SWALL SEA | 180.00 | 90.00 | S | ||
F9WINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 NWALL NEA | 0.00 | 90.00 | N | ||
F9WINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F9 EWALL NEA | 90.00 | 90.00 | E | ||
F9WINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 NWALL N1A | 0.00 | 90.00 | N | ||
F9WINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 NWALL N2A | 0.00 | 90.00 | N | ||
F9WINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 SWALL S1A | 180.00 | 90.00 | S | ||
F9WINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 SWALL S2A | 180.00 | 90.00 | S | ||
F9WINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F9 WWALL C | 270.00 | 90.00 | W | ||
F9WINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F9 EWALL C | 90.00 | 90.00 | E | ||
TWINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | T WWALL C | 270.00 | 90.00 | W | ||
TWINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | T EWALL C | 90.00 | 90.00 | E | ||
Total or Average | 1150.39 | 4.600 | 0.293 | 0.130 | ||||||||||||
North Total or Average | 423.59 | 4.600 | 0.293 | 0.130 | ||||||||||||
Non-North Total or Average | 726.80 | 4.600 | 0.293 | 0.130 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:11
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:11
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
G SW APARTMENT_LIGHTS_HARDWIRED | G SW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
G NW APARTMENT_LIGHTS_HARDWIRED | G NW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
OFFICE_LIGHTS_HARDWIRED | OFFICE | 11.9479 | 88.25 | 1054.39 | GeneralLights | LTG_OFF_SCH | 56.26 | 168.00 | 55.46 | 0.0000 | Y | 10.98 |
G NE APARTMENT_LIGHTS_HARDWIRED | G NE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
G N1 APARTMENT_LIGHTS_HARDWIRED | G N1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
G N2 APARTMENT_LIGHTS_HARDWIRED | G N2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
G S1 APARTMENT_LIGHTS_HARDWIRED | G S1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
G S2 APARTMENT_LIGHTS_HARDWIRED | G S2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
G CORRIDOR_LIGHTS_HARDWIRED | G CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
F2 SW APARTMENT_LIGHTS_HARDWIRED | F2 SW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F2 NW APARTMENT_LIGHTS_HARDWIRED | F2 NW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F2 SE APARTMENT_LIGHTS_HARDWIRED | F2 SE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F2 NE APARTMENT_LIGHTS_HARDWIRED | F2 NE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F2 N1 APARTMENT_LIGHTS_HARDWIRED | F2 N1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F2 N2 APARTMENT_LIGHTS_HARDWIRED | F2 N2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F2 S1 APARTMENT_LIGHTS_HARDWIRED | F2 S1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F2 S2 APARTMENT_LIGHTS_HARDWIRED | F2 S2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F2 CORRIDOR_LIGHTS_HARDWIRED | F2 CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
F3 SW APARTMENT_LIGHTS_HARDWIRED | F3 SW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F3 NW APARTMENT_LIGHTS_HARDWIRED | F3 NW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F3 SE APARTMENT_LIGHTS_HARDWIRED | F3 SE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F3 NE APARTMENT_LIGHTS_HARDWIRED | F3 NE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F3 N1 APARTMENT_LIGHTS_HARDWIRED | F3 N1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F3 N2 APARTMENT_LIGHTS_HARDWIRED | F3 N2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F3 S1 APARTMENT_LIGHTS_HARDWIRED | F3 S1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F3 S2 APARTMENT_LIGHTS_HARDWIRED | F3 S2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F3 CORRIDOR_LIGHTS_HARDWIRED | F3 CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
F4 SW APARTMENT_LIGHTS_HARDWIRED | F4 SW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F4 NW APARTMENT_LIGHTS_HARDWIRED | F4 NW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F4 SE APARTMENT_LIGHTS_HARDWIRED | F4 SE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F4 NE APARTMENT_LIGHTS_HARDWIRED | F4 NE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F4 N1 APARTMENT_LIGHTS_HARDWIRED | F4 N1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F4 N2 APARTMENT_LIGHTS_HARDWIRED | F4 N2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F4 S1 APARTMENT_LIGHTS_HARDWIRED | F4 S1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F4 S2 APARTMENT_LIGHTS_HARDWIRED | F4 S2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F4 CORRIDOR_LIGHTS_HARDWIRED | F4 CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
M SW APARTMENT_LIGHTS_HARDWIRED | M SW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
M NW APARTMENT_LIGHTS_HARDWIRED | M NW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
M SE APARTMENT_LIGHTS_HARDWIRED | M SE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
M NE APARTMENT_LIGHTS_HARDWIRED | M NE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
M N1 APARTMENT_LIGHTS_HARDWIRED | M N1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
M N2 APARTMENT_LIGHTS_HARDWIRED | M N2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
M S1 APARTMENT_LIGHTS_HARDWIRED | M S1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
M S2 APARTMENT_LIGHTS_HARDWIRED | M S2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
M CORRIDOR_LIGHTS_HARDWIRED | M CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
F6 SW APARTMENT_LIGHTS_HARDWIRED | F6 SW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F6 NW APARTMENT_LIGHTS_HARDWIRED | F6 NW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F6 SE APARTMENT_LIGHTS_HARDWIRED | F6 SE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F6 NE APARTMENT_LIGHTS_HARDWIRED | F6 NE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F6 N1 APARTMENT_LIGHTS_HARDWIRED | F6 N1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F6 N2 APARTMENT_LIGHTS_HARDWIRED | F6 N2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F6 S1 APARTMENT_LIGHTS_HARDWIRED | F6 S1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F6 S2 APARTMENT_LIGHTS_HARDWIRED | F6 S2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F6 CORRIDOR_LIGHTS_HARDWIRED | F6 CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
F7 SW APARTMENT_LIGHTS_HARDWIRED | F7 SW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F7 NW APARTMENT_LIGHTS_HARDWIRED | F7 NW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F7 SE APARTMENT_LIGHTS_HARDWIRED | F7 SE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F7 NE APARTMENT_LIGHTS_HARDWIRED | F7 NE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F7 N1 APARTMENT_LIGHTS_HARDWIRED | F7 N1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F7 N2 APARTMENT_LIGHTS_HARDWIRED | F7 N2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F7 S1 APARTMENT_LIGHTS_HARDWIRED | F7 S1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F7 S2 APARTMENT_LIGHTS_HARDWIRED | F7 S2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F7 CORRIDOR_LIGHTS_HARDWIRED | F7 CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
F8 SW APARTMENT_LIGHTS_HARDWIRED | F8 SW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F8 NW APARTMENT_LIGHTS_HARDWIRED | F8 NW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F8 SE APARTMENT_LIGHTS_HARDWIRED | F8 SE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F8 NE APARTMENT_LIGHTS_HARDWIRED | F8 NE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F8 N1 APARTMENT_LIGHTS_HARDWIRED | F8 N1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F8 N2 APARTMENT_LIGHTS_HARDWIRED | F8 N2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F8 S1 APARTMENT_LIGHTS_HARDWIRED | F8 S1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F8 S2 APARTMENT_LIGHTS_HARDWIRED | F8 S2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F8 CORRIDOR_LIGHTS_HARDWIRED | F8 CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
F9 SW APARTMENT_LIGHTS_HARDWIRED | F9 SW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F9 NW APARTMENT_LIGHTS_HARDWIRED | F9 NW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F9 SE APARTMENT_LIGHTS_HARDWIRED | F9 SE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F9 NE APARTMENT_LIGHTS_HARDWIRED | F9 NE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F9 N1 APARTMENT_LIGHTS_HARDWIRED | F9 N1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F9 N2 APARTMENT_LIGHTS_HARDWIRED | F9 N2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F9 S1 APARTMENT_LIGHTS_HARDWIRED | F9 S1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F9 S2 APARTMENT_LIGHTS_HARDWIRED | F9 S2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
F9 CORRIDOR_LIGHTS_HARDWIRED | F9 CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
T SW APARTMENT_LIGHTS_HARDWIRED | T SW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
T NW APARTMENT_LIGHTS_HARDWIRED | T NW APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
T SE APARTMENT_LIGHTS_HARDWIRED | T SE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
T NE APARTMENT_LIGHTS_HARDWIRED | T NE APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
T N1 APARTMENT_LIGHTS_HARDWIRED | T N1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
T N2 APARTMENT_LIGHTS_HARDWIRED | T N2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
T S1 APARTMENT_LIGHTS_HARDWIRED | T S1 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
T S2 APARTMENT_LIGHTS_HARDWIRED | T S2 APARTMENT | 11.5174 | 88.25 | 1016.39 | GeneralLights | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 1.93 |
T CORRIDOR_LIGHTS_HARDWIRED | T CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
G SW APARTMENT_LIGHTS_PLUGIN | G SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
G NW APARTMENT_LIGHTS_PLUGIN | G NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
OFFICE_LIGHTS_PLUGIN | OFFICE | 11.9479 | 88.25 | 1054.39 | GeneralLights-plugin | LTG_OFF_SCH | 56.26 | 168.00 | 55.46 | 0.0000 | Y | 10.98 |
G NE APARTMENT_LIGHTS_PLUGIN | G NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
G N1 APARTMENT_LIGHTS_PLUGIN | G N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
G N2 APARTMENT_LIGHTS_PLUGIN | G N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
G S1 APARTMENT_LIGHTS_PLUGIN | G S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
G S2 APARTMENT_LIGHTS_PLUGIN | G S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F2 SW APARTMENT_LIGHTS_PLUGIN | F2 SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F2 NW APARTMENT_LIGHTS_PLUGIN | F2 NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F2 SE APARTMENT_LIGHTS_PLUGIN | F2 SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F2 NE APARTMENT_LIGHTS_PLUGIN | F2 NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F2 N1 APARTMENT_LIGHTS_PLUGIN | F2 N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F2 N2 APARTMENT_LIGHTS_PLUGIN | F2 N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F2 S1 APARTMENT_LIGHTS_PLUGIN | F2 S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F2 S2 APARTMENT_LIGHTS_PLUGIN | F2 S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F3 SW APARTMENT_LIGHTS_PLUGIN | F3 SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F3 NW APARTMENT_LIGHTS_PLUGIN | F3 NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F3 SE APARTMENT_LIGHTS_PLUGIN | F3 SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F3 NE APARTMENT_LIGHTS_PLUGIN | F3 NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F3 N1 APARTMENT_LIGHTS_PLUGIN | F3 N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F3 N2 APARTMENT_LIGHTS_PLUGIN | F3 N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F3 S1 APARTMENT_LIGHTS_PLUGIN | F3 S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F3 S2 APARTMENT_LIGHTS_PLUGIN | F3 S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F4 SW APARTMENT_LIGHTS_PLUGIN | F4 SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F4 NW APARTMENT_LIGHTS_PLUGIN | F4 NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F4 SE APARTMENT_LIGHTS_PLUGIN | F4 SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F4 NE APARTMENT_LIGHTS_PLUGIN | F4 NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F4 N1 APARTMENT_LIGHTS_PLUGIN | F4 N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F4 N2 APARTMENT_LIGHTS_PLUGIN | F4 N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F4 S1 APARTMENT_LIGHTS_PLUGIN | F4 S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F4 S2 APARTMENT_LIGHTS_PLUGIN | F4 S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
M SW APARTMENT_LIGHTS_PLUGIN | M SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
M NW APARTMENT_LIGHTS_PLUGIN | M NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
M SE APARTMENT_LIGHTS_PLUGIN | M SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
M NE APARTMENT_LIGHTS_PLUGIN | M NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
M N1 APARTMENT_LIGHTS_PLUGIN | M N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
M N2 APARTMENT_LIGHTS_PLUGIN | M N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
M S1 APARTMENT_LIGHTS_PLUGIN | M S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
M S2 APARTMENT_LIGHTS_PLUGIN | M S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
M CORRIDOR_LIGHTS_PLUGIN | M CORRIDOR | 8.5250 | 77.66 | 662.04 | GeneralLights-plugin | LTG_COR_SCH | 149.10 | 168.00 | 149.10 | 0.0000 | N | 18.53 |
F6 SW APARTMENT_LIGHTS_PLUGIN | F6 SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F6 NW APARTMENT_LIGHTS_PLUGIN | F6 NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F6 SE APARTMENT_LIGHTS_PLUGIN | F6 SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F6 NE APARTMENT_LIGHTS_PLUGIN | F6 NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F6 N1 APARTMENT_LIGHTS_PLUGIN | F6 N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F6 N2 APARTMENT_LIGHTS_PLUGIN | F6 N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F6 S1 APARTMENT_LIGHTS_PLUGIN | F6 S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F6 S2 APARTMENT_LIGHTS_PLUGIN | F6 S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F7 SW APARTMENT_LIGHTS_PLUGIN | F7 SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F7 NW APARTMENT_LIGHTS_PLUGIN | F7 NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F7 SE APARTMENT_LIGHTS_PLUGIN | F7 SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F7 NE APARTMENT_LIGHTS_PLUGIN | F7 NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F7 N1 APARTMENT_LIGHTS_PLUGIN | F7 N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F7 N2 APARTMENT_LIGHTS_PLUGIN | F7 N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F7 S1 APARTMENT_LIGHTS_PLUGIN | F7 S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F7 S2 APARTMENT_LIGHTS_PLUGIN | F7 S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F8 SW APARTMENT_LIGHTS_PLUGIN | F8 SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F8 NW APARTMENT_LIGHTS_PLUGIN | F8 NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F8 SE APARTMENT_LIGHTS_PLUGIN | F8 SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F8 NE APARTMENT_LIGHTS_PLUGIN | F8 NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F8 N1 APARTMENT_LIGHTS_PLUGIN | F8 N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F8 N2 APARTMENT_LIGHTS_PLUGIN | F8 N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F8 S1 APARTMENT_LIGHTS_PLUGIN | F8 S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F8 S2 APARTMENT_LIGHTS_PLUGIN | F8 S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F9 SW APARTMENT_LIGHTS_PLUGIN | F9 SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F9 NW APARTMENT_LIGHTS_PLUGIN | F9 NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F9 SE APARTMENT_LIGHTS_PLUGIN | F9 SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F9 NE APARTMENT_LIGHTS_PLUGIN | F9 NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F9 N1 APARTMENT_LIGHTS_PLUGIN | F9 N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F9 N2 APARTMENT_LIGHTS_PLUGIN | F9 N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F9 S1 APARTMENT_LIGHTS_PLUGIN | F9 S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
F9 S2 APARTMENT_LIGHTS_PLUGIN | F9 S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
T SW APARTMENT_LIGHTS_PLUGIN | T SW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
T NW APARTMENT_LIGHTS_PLUGIN | T NW APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
T SE APARTMENT_LIGHTS_PLUGIN | T SE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
T NE APARTMENT_LIGHTS_PLUGIN | T NE APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
T N1 APARTMENT_LIGHTS_PLUGIN | T N1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
T N2 APARTMENT_LIGHTS_PLUGIN | T N2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
T S1 APARTMENT_LIGHTS_PLUGIN | T S1 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
T S2 APARTMENT_LIGHTS_PLUGIN | T S2 APARTMENT | 2.9063 | 88.25 | 256.47 | GeneralLights-plugin | LTG_APT_SCH | 10.10 | 168.00 | 10.10 | 0.0000 | Y | 0.49 |
Interior Lighting Total | 7.3426 | 14974.03 | 109947.72 | 416.41 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 10720.10 | AstronomicalClock | - | 83.74 | 83.74 | 168.51 | |
Exterior Lighting Total | 10720.10 | 168.51 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:11
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
CENTRAL BOILER | Boiler:HotWater | 299343.48 | 0.80 | ||
CENTRAL TOWER | EvaporativeFluidCooler:SingleSpeed | 239474.78 |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
HEAT PUMP COOLING MODE AIRLOOP G SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4243.04 | 2984.76 | 1258.28 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4183.96 | 2946.65 | 1237.31 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP OFFICE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5085.53 | 3591.12 | 1494.41 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3334.17 | 2363.95 | 970.22 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2349.11 | 1643.81 | 705.30 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2334.02 | 1633.15 | 700.87 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2535.29 | 1753.96 | 781.33 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2601.05 | 1800.76 | 800.29 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4853.94 | 3430.15 | 1423.79 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4784.33 | 3382.77 | 1401.56 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4373.99 | 3101.35 | 1272.64 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3891.60 | 2766.56 | 1125.04 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2730.89 | 1921.22 | 809.66 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2719.23 | 1912.97 | 806.26 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2956.60 | 2060.46 | 896.14 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2979.47 | 2076.71 | 902.77 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4837.17 | 3425.54 | 1411.64 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4769.50 | 3379.55 | 1389.95 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4163.72 | 2959.75 | 1203.97 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3903.00 | 2781.77 | 1121.23 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2748.34 | 1937.76 | 810.57 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2736.99 | 1929.73 | 807.26 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2979.61 | 2080.95 | 898.66 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2989.72 | 2088.13 | 901.59 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4842.12 | 3434.47 | 1407.65 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4774.99 | 3389.91 | 1385.08 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4152.90 | 2957.48 | 1195.43 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3912.13 | 2793.59 | 1118.54 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2768.72 | 1955.34 | 813.38 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2757.58 | 1947.45 | 810.13 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2999.64 | 2098.30 | 901.35 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3007.87 | 2104.14 | 903.73 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4881.49 | 3466.77 | 1414.73 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4814.58 | 3422.38 | 1392.20 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4203.87 | 2995.16 | 1208.71 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3955.20 | 2828.47 | 1126.72 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2819.79 | 1994.05 | 825.74 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2808.82 | 1986.28 | 822.54 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3049.35 | 2136.18 | 913.17 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3057.28 | 2141.81 | 915.47 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4839.40 | 3439.66 | 1399.74 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4764.82 | 3391.00 | 1373.82 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4161.69 | 2969.01 | 1192.68 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3909.83 | 2800.05 | 1109.77 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2782.20 | 1969.65 | 812.55 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2771.44 | 1962.02 | 809.42 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3012.82 | 2112.38 | 900.44 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3020.68 | 2117.96 | 902.72 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4824.90 | 3432.74 | 1392.16 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4749.51 | 3383.53 | 1365.98 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4151.50 | 2965.08 | 1186.43 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3897.85 | 2794.84 | 1103.01 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2776.35 | 1967.44 | 808.91 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2765.74 | 1959.91 | 805.83 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3006.73 | 2109.96 | 896.77 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3014.55 | 2115.52 | 899.04 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4831.34 | 3440.30 | 1391.04 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4755.22 | 3390.58 | 1364.64 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4161.15 | 2974.86 | 1186.29 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3905.68 | 2803.33 | 1102.35 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2790.32 | 1979.06 | 811.25 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2779.86 | 1971.65 | 808.21 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3019.82 | 2120.99 | 898.83 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3027.62 | 2126.53 | 901.09 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4952.70 | 3530.07 | 1422.63 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4882.70 | 3483.55 | 1399.14 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4240.41 | 3033.76 | 1206.64 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3975.99 | 2855.89 | 1120.10 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2913.73 | 2068.07 | 845.66 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2903.36 | 2060.72 | 842.64 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3118.74 | 2191.44 | 927.30 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3126.40 | 2196.88 | 929.52 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5820.94 | 4144.76 | 1676.19 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5708.25 | 4067.27 | 1640.98 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5093.90 | 3621.54 | 1472.35 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4642.57 | 3323.94 | 1318.63 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3515.81 | 2493.40 | 1022.41 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3565.58 | 2512.02 | 1053.56 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3988.37 | 2810.42 | 1177.95 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3995.68 | 2815.59 | 1180.09 | 0.70 | 0.00 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
None |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
HEAT PUMP HEATING MODE AIRLOOP G SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4243.04 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4183.96 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP OFFICE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5085.53 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3334.17 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2349.11 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2334.02 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2535.29 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2601.05 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4853.94 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4784.33 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4373.99 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3891.60 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2730.89 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2719.23 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2956.60 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2979.47 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4837.17 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4769.50 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4163.72 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3903.00 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2748.34 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2736.99 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2979.61 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2989.72 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4842.12 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4774.99 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4152.90 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3912.13 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2768.72 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2757.58 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2999.64 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3007.87 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4881.49 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4814.58 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4203.87 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3955.20 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2819.79 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2808.82 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3049.35 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3057.28 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4839.40 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4764.82 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4161.69 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3909.83 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2782.20 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2771.44 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3012.82 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3020.68 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4824.90 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4749.51 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4151.50 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3897.85 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2776.35 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2765.74 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3006.73 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3014.55 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4831.34 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4755.22 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4161.15 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3905.68 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2790.32 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2779.86 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3019.82 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3027.62 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4952.70 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4882.70 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4240.41 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3975.99 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2913.73 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2903.36 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3118.74 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3126.40 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5820.94 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5708.25 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5093.90 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4642.57 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3515.81 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3565.58 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3988.37 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3995.68 | 0.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW | Coil:Heating:Electric | 2082.56 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW | Coil:Heating:Electric | 2093.15 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE | Coil:Heating:Electric | 2763.96 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE | Coil:Heating:Electric | 2087.42 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 | Coil:Heating:Electric | 1491.36 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 | Coil:Heating:Electric | 1491.27 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 | Coil:Heating:Electric | 1478.41 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 | Coil:Heating:Electric | 1486.73 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW | Coil:Heating:Electric | 2009.86 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW | Coil:Heating:Electric | 2019.31 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE | Coil:Heating:Electric | 2030.18 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE | Coil:Heating:Electric | 2013.51 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 | Coil:Heating:Electric | 1314.37 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 | Coil:Heating:Electric | 1314.27 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 | Coil:Heating:Electric | 1307.62 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 | Coil:Heating:Electric | 1309.38 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW | Coil:Heating:Electric | 1978.95 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW | Coil:Heating:Electric | 1987.31 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE | Coil:Heating:Electric | 1977.14 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE | Coil:Heating:Electric | 1982.33 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 | Coil:Heating:Electric | 1267.10 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 | Coil:Heating:Electric | 1267.01 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 | Coil:Heating:Electric | 1259.30 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 | Coil:Heating:Electric | 1259.53 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW | Coil:Heating:Electric | 1987.64 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW | Coil:Heating:Electric | 1995.13 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE | Coil:Heating:Electric | 1983.84 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE | Coil:Heating:Electric | 1990.96 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 | Coil:Heating:Electric | 1262.23 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 | Coil:Heating:Electric | 1262.15 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 | Coil:Heating:Electric | 1255.00 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 | Coil:Heating:Electric | 1254.98 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW | Coil:Heating:Electric | 1979.49 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW | Coil:Heating:Electric | 1984.83 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE | Coil:Heating:Electric | 1976.14 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE | Coil:Heating:Electric | 1981.43 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 | Coil:Heating:Electric | 1245.13 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 | Coil:Heating:Electric | 1245.07 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 | Coil:Heating:Electric | 1240.02 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 | Coil:Heating:Electric | 1239.97 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW | Coil:Heating:Electric | 2038.34 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW | Coil:Heating:Electric | 2043.54 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE | Coil:Heating:Electric | 2035.65 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE | Coil:Heating:Electric | 2040.85 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 | Coil:Heating:Electric | 1291.38 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 | Coil:Heating:Electric | 1291.33 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 | Coil:Heating:Electric | 1286.37 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 | Coil:Heating:Electric | 1286.32 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW | Coil:Heating:Electric | 2073.15 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW | Coil:Heating:Electric | 2077.09 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE | Coil:Heating:Electric | 2071.11 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE | Coil:Heating:Electric | 2075.05 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 | Coil:Heating:Electric | 1317.05 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 | Coil:Heating:Electric | 1317.01 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 | Coil:Heating:Electric | 1313.28 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 | Coil:Heating:Electric | 1313.24 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW | Coil:Heating:Electric | 2110.78 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW | Coil:Heating:Electric | 2113.39 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE | Coil:Heating:Electric | 2109.35 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE | Coil:Heating:Electric | 2111.96 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 | Coil:Heating:Electric | 1346.83 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 | Coil:Heating:Electric | 1346.81 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 | Coil:Heating:Electric | 1344.40 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 | Coil:Heating:Electric | 1344.37 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW | Coil:Heating:Electric | 2240.53 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW | Coil:Heating:Electric | 2240.16 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE | Coil:Heating:Electric | 2239.67 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE | Coil:Heating:Electric | 2239.30 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 | Coil:Heating:Electric | 1460.96 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 | Coil:Heating:Electric | 1460.95 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 | Coil:Heating:Electric | 1461.26 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 | Coil:Heating:Electric | 1461.25 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW | Coil:Heating:Electric | 2692.67 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW | Coil:Heating:Electric | 2695.76 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE | Coil:Heating:Electric | 2692.34 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE | Coil:Heating:Electric | 2695.43 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 | Coil:Heating:Electric | 1952.16 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 | Coil:Heating:Electric | 1952.16 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 | Coil:Heating:Electric | 1948.17 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 | Coil:Heating:Electric | 1948.16 | 1.00 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
AIRLOOP G SW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 345.27 | 1120.11 | 1.00 | General |
AIRLOOP G NW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 342.05 | 1120.11 | 1.00 | General |
AIRLOOP OFFICE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 414.20 | 1120.11 | 1.00 | General |
AIRLOOP G NE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.24 | 274.00 | 1120.11 | 1.00 | General |
AIRLOOP G N1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.17 | 186.02 | 1120.11 | 1.00 | General |
AIRLOOP G N2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.16 | 184.74 | 1120.11 | 1.00 | General |
AIRLOOP G S1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.17 | 194.73 | 1120.11 | 1.00 | General |
AIRLOOP G S2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.18 | 200.34 | 1120.11 | 1.00 | General |
AIRLOOP F2 SW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.36 | 400.14 | 1120.11 | 1.00 | General |
AIRLOOP F2 NW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.35 | 395.46 | 1120.11 | 1.00 | General |
AIRLOOP F2 SE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.32 | 362.02 | 1120.11 | 1.00 | General |
AIRLOOP F2 NE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.29 | 322.65 | 1120.11 | 1.00 | General |
AIRLOOP F2 N1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 219.36 | 1120.11 | 1.00 | General |
AIRLOOP F2 N2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.19 | 218.37 | 1120.11 | 1.00 | General |
AIRLOOP F2 S1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.21 | 231.92 | 1120.11 | 1.00 | General |
AIRLOOP F2 S2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.21 | 233.88 | 1120.11 | 1.00 | General |
AIRLOOP F3 SW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.36 | 399.95 | 1120.11 | 1.00 | General |
AIRLOOP F3 NW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.35 | 395.44 | 1120.11 | 1.00 | General |
AIRLOOP F3 SE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 345.23 | 1120.11 | 1.00 | General |
AIRLOOP F3 NE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.29 | 324.85 | 1120.11 | 1.00 | General |
AIRLOOP F3 N1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 221.57 | 1120.11 | 1.00 | General |
AIRLOOP F3 N2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 220.60 | 1120.11 | 1.00 | General |
AIRLOOP F3 S1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.21 | 234.60 | 1120.11 | 1.00 | General |
AIRLOOP F3 S2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.21 | 235.46 | 1120.11 | 1.00 | General |
AIRLOOP F4 SW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.36 | 401.31 | 1120.11 | 1.00 | General |
AIRLOOP F4 NW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.35 | 396.68 | 1120.11 | 1.00 | General |
AIRLOOP F4 SE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 345.23 | 1120.11 | 1.00 | General |
AIRLOOP F4 NE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.29 | 326.55 | 1120.11 | 1.00 | General |
AIRLOOP F4 N1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 223.85 | 1120.11 | 1.00 | General |
AIRLOOP F4 N2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 222.90 | 1120.11 | 1.00 | General |
AIRLOOP F4 S1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.21 | 236.84 | 1120.11 | 1.00 | General |
AIRLOOP F4 S2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.21 | 237.55 | 1120.11 | 1.00 | General |
AIRLOOP M SW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.36 | 405.45 | 1120.11 | 1.00 | General |
AIRLOOP M NW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.36 | 400.84 | 1120.11 | 1.00 | General |
AIRLOOP M SE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 349.53 | 1120.11 | 1.00 | General |
AIRLOOP M NE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.30 | 331.00 | 1120.11 | 1.00 | General |
AIRLOOP M N1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 228.65 | 1120.11 | 1.00 | General |
AIRLOOP M N2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 227.71 | 1120.11 | 1.00 | General |
AIRLOOP M S1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.22 | 241.54 | 1120.11 | 1.00 | General |
AIRLOOP M S2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.22 | 242.21 | 1120.11 | 1.00 | General |
AIRLOOP F6 SW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.36 | 402.02 | 1120.11 | 1.00 | General |
AIRLOOP F6 NW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.35 | 397.23 | 1120.11 | 1.00 | General |
AIRLOOP F6 SE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 346.55 | 1120.11 | 1.00 | General |
AIRLOOP F6 NE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.29 | 327.74 | 1120.11 | 1.00 | General |
AIRLOOP F6 N1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 225.81 | 1120.11 | 1.00 | General |
AIRLOOP F6 N2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 224.89 | 1120.11 | 1.00 | General |
AIRLOOP F6 S1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.21 | 238.78 | 1120.11 | 1.00 | General |
AIRLOOP F6 S2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.21 | 239.45 | 1120.11 | 1.00 | General |
AIRLOOP F7 SW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.36 | 401.35 | 1120.11 | 1.00 | General |
AIRLOOP F7 NW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.35 | 396.49 | 1120.11 | 1.00 | General |
AIRLOOP F7 SE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 346.24 | 1120.11 | 1.00 | General |
AIRLOOP F7 NE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.29 | 327.27 | 1120.11 | 1.00 | General |
AIRLOOP F7 N1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 225.64 | 1120.11 | 1.00 | General |
AIRLOOP F7 N2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 224.74 | 1120.11 | 1.00 | General |
AIRLOOP F7 S1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.21 | 238.58 | 1120.11 | 1.00 | General |
AIRLOOP F7 S2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.21 | 239.25 | 1120.11 | 1.00 | General |
AIRLOOP F8 SW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.36 | 402.42 | 1120.11 | 1.00 | General |
AIRLOOP F8 NW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.35 | 397.50 | 1120.11 | 1.00 | General |
AIRLOOP F8 SE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.31 | 347.57 | 1120.11 | 1.00 | General |
AIRLOOP F8 NE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.29 | 328.45 | 1120.11 | 1.00 | General |
AIRLOOP F8 N1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 227.13 | 1120.11 | 1.00 | General |
AIRLOOP F8 N2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.20 | 226.24 | 1120.11 | 1.00 | General |
AIRLOOP F8 S1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.21 | 240.00 | 1120.11 | 1.00 | General |
AIRLOOP F8 S2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.21 | 240.66 | 1120.11 | 1.00 | General |
AIRLOOP F9 SW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 413.77 | 1120.11 | 1.00 | General |
AIRLOOP F9 NW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.37 | 408.91 | 1120.11 | 1.00 | General |
AIRLOOP F9 SE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.32 | 354.85 | 1120.11 | 1.00 | General |
AIRLOOP F9 NE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.30 | 334.95 | 1120.11 | 1.00 | General |
AIRLOOP F9 N1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.21 | 237.96 | 1120.11 | 1.00 | General |
AIRLOOP F9 N2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.21 | 237.08 | 1120.11 | 1.00 | General |
AIRLOOP F9 S1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.22 | 248.35 | 1120.11 | 1.00 | General |
AIRLOOP F9 S2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.22 | 249.00 | 1120.11 | 1.00 | General |
AIRLOOP T SW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.44 | 487.75 | 1120.11 | 1.00 | General |
AIRLOOP T NW SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.43 | 479.03 | 1120.11 | 1.00 | General |
AIRLOOP T SE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.38 | 422.78 | 1120.11 | 1.00 | General |
AIRLOOP T NE SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.35 | 390.63 | 1120.11 | 1.00 | General |
AIRLOOP T N1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 288.85 | 1120.11 | 1.00 | General |
AIRLOOP T N2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.26 | 287.39 | 1120.11 | 1.00 | General |
AIRLOOP T S1 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.29 | 323.19 | 1120.11 | 1.00 | General |
AIRLOOP T S2 SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.29 | 323.81 | 1120.11 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
SHWSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.0003 | 36.93 | 127739.32 | 0.30 |
PLANT CIRC PUMP | Pump:ConstantSpeed | Intermittent | 179045.11 | 0.0065 | 1660.62 | 255050.01 | 0.90 |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SHWSYS1 WATER HEATER | WaterHeater:Mixed | 2.27 | 175842.64 | 0.80 | 0.00 | 0.00 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:11
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 2978.07 | 3573.69 | 0.257 | 0.308 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 39.47 | 0.00558 |
G NW APARTMENT | 2950.25 | 3540.30 | 0.254 | 0.305 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 38.27 | 0.00558 |
OFFICE | 3572.68 | 4287.21 | 0.308 | 0.370 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 11:15:00 | 38.07 | 0.00558 |
G NE APARTMENT | 2363.34 | 2836.01 | 0.204 | 0.245 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 36.74 | 0.00558 |
G N1 APARTMENT | 1604.47 | 1925.36 | 0.138 | 0.166 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 36.61 | 0.00558 |
G N2 APARTMENT | 1593.42 | 1912.11 | 0.137 | 0.165 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 36.61 | 0.00558 |
G S1 APARTMENT | 1679.56 | 2015.47 | 0.145 | 0.174 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 40.63 | 0.00558 |
G S2 APARTMENT | 1728.01 | 2073.62 | 0.149 | 0.179 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 40.63 | 0.00558 |
F2 SW APARTMENT | 3451.37 | 4141.64 | 0.298 | 0.357 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 39.20 | 0.00558 |
F2 NW APARTMENT | 3410.96 | 4093.15 | 0.294 | 0.353 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 38.27 | 0.00558 |
F2 SE APARTMENT | 3122.55 | 3747.06 | 0.269 | 0.323 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 11:15:00 | 38.07 | 0.00558 |
F2 NE APARTMENT | 2782.96 | 3339.55 | 0.240 | 0.288 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 37.24 | 0.00558 |
F2 N1 APARTMENT | 1892.04 | 2270.45 | 0.163 | 0.196 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 37.11 | 0.00558 |
F2 N2 APARTMENT | 1883.46 | 2260.15 | 0.162 | 0.195 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 37.11 | 0.00558 |
F2 S1 APARTMENT | 2000.38 | 2400.46 | 0.173 | 0.207 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 40.63 | 0.00558 |
F2 S2 APARTMENT | 2017.25 | 2420.71 | 0.174 | 0.209 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 40.63 | 0.00558 |
F3 SW APARTMENT | 3449.75 | 4139.71 | 0.298 | 0.357 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 39.20 | 0.00558 |
F3 NW APARTMENT | 3410.80 | 4092.96 | 0.294 | 0.353 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 38.27 | 0.00558 |
F3 SE APARTMENT | 2977.78 | 3573.33 | 0.257 | 0.308 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 11:15:00 | 38.07 | 0.00558 |
F3 NE APARTMENT | 2801.98 | 3362.38 | 0.242 | 0.290 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 37.24 | 0.00558 |
F3 N1 APARTMENT | 1911.09 | 2293.30 | 0.165 | 0.198 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 37.11 | 0.00558 |
F3 N2 APARTMENT | 1902.72 | 2283.27 | 0.164 | 0.197 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 37.11 | 0.00558 |
F3 S1 APARTMENT | 2023.47 | 2428.16 | 0.175 | 0.209 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 40.63 | 0.00558 |
F3 S2 APARTMENT | 2030.93 | 2437.11 | 0.175 | 0.210 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 40.63 | 0.00558 |
F4 SW APARTMENT | 3461.49 | 4153.78 | 0.299 | 0.358 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 39.20 | 0.00558 |
F4 NW APARTMENT | 3421.53 | 4105.84 | 0.295 | 0.354 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 38.61 | 0.00558 |
F4 SE APARTMENT | 2977.75 | 3573.31 | 0.257 | 0.308 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 11:15:00 | 38.07 | 0.00558 |
F4 NE APARTMENT | 2816.67 | 3380.00 | 0.243 | 0.292 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 37.24 | 0.00558 |
F4 N1 APARTMENT | 1930.74 | 2316.89 | 0.167 | 0.200 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 37.11 | 0.00558 |
F4 N2 APARTMENT | 1922.53 | 2307.04 | 0.166 | 0.199 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 37.11 | 0.00558 |
F4 S1 APARTMENT | 2042.85 | 2451.42 | 0.176 | 0.211 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 40.63 | 0.00558 |
F4 S2 APARTMENT | 2048.92 | 2458.71 | 0.177 | 0.212 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 40.63 | 0.00558 |
M SW APARTMENT | 3497.20 | 4196.64 | 0.302 | 0.362 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 39.20 | 0.00558 |
M NW APARTMENT | 3457.43 | 4148.92 | 0.298 | 0.358 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 38.61 | 0.00558 |
M SE APARTMENT | 3014.92 | 3617.91 | 0.260 | 0.312 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 11:30:00 | 38.41 | 0.00558 |
M NE APARTMENT | 2855.03 | 3426.04 | 0.246 | 0.296 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 37.24 | 0.00558 |
M N1 APARTMENT | 1972.16 | 2366.60 | 0.170 | 0.204 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 37.11 | 0.00558 |
M N2 APARTMENT | 1964.07 | 2356.88 | 0.169 | 0.203 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 37.11 | 0.00558 |
M S1 APARTMENT | 2083.34 | 2500.01 | 0.180 | 0.216 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 40.63 | 0.00558 |
M S2 APARTMENT | 2089.19 | 2507.03 | 0.180 | 0.216 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 40.63 | 0.00558 |
F6 SW APARTMENT | 3467.69 | 4161.23 | 0.299 | 0.359 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 39.47 | 0.00558 |
F6 NW APARTMENT | 3426.32 | 4111.58 | 0.296 | 0.355 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 38.61 | 0.00558 |
F6 SE APARTMENT | 2989.22 | 3587.07 | 0.258 | 0.309 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 11:30:00 | 38.41 | 0.00558 |
F6 NE APARTMENT | 2826.94 | 3392.33 | 0.244 | 0.293 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 37.24 | 0.00558 |
F6 N1 APARTMENT | 1947.72 | 2337.26 | 0.168 | 0.202 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 37.11 | 0.00558 |
F6 N2 APARTMENT | 1939.77 | 2327.72 | 0.167 | 0.201 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 37.11 | 0.00558 |
F6 S1 APARTMENT | 2059.54 | 2471.45 | 0.178 | 0.213 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 40.63 | 0.00558 |
F6 S2 APARTMENT | 2065.34 | 2478.41 | 0.178 | 0.214 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 40.63 | 0.00558 |
F7 SW APARTMENT | 3461.93 | 4154.31 | 0.299 | 0.358 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 39.47 | 0.00558 |
F7 NW APARTMENT | 3419.98 | 4103.97 | 0.295 | 0.354 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 38.61 | 0.00558 |
F7 SE APARTMENT | 2986.54 | 3583.85 | 0.258 | 0.309 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 11:30:00 | 38.41 | 0.00558 |
F7 NE APARTMENT | 2822.91 | 3387.50 | 0.243 | 0.292 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 37.24 | 0.00558 |
F7 N1 APARTMENT | 1946.25 | 2335.50 | 0.168 | 0.201 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 37.11 | 0.00558 |
F7 N2 APARTMENT | 1938.42 | 2326.10 | 0.167 | 0.201 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 37.11 | 0.00558 |
F7 S1 APARTMENT | 2057.86 | 2469.43 | 0.177 | 0.213 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 40.63 | 0.00558 |
F7 S2 APARTMENT | 2063.63 | 2476.36 | 0.178 | 0.214 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 40.63 | 0.00558 |
F8 SW APARTMENT | 3471.15 | 4165.38 | 0.299 | 0.359 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 39.47 | 0.00558 |
F8 NW APARTMENT | 3428.67 | 4114.40 | 0.296 | 0.355 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 38.61 | 0.00558 |
F8 SE APARTMENT | 2998.05 | 3597.66 | 0.259 | 0.310 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 11:30:00 | 38.41 | 0.00558 |
F8 NE APARTMENT | 2833.06 | 3399.67 | 0.244 | 0.293 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 37.24 | 0.00558 |
F8 N1 APARTMENT | 1959.11 | 2350.93 | 0.169 | 0.203 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 37.11 | 0.00558 |
F8 N2 APARTMENT | 1951.38 | 2341.66 | 0.168 | 0.202 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 37.11 | 0.00558 |
F8 S1 APARTMENT | 2070.07 | 2484.09 | 0.179 | 0.214 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 40.63 | 0.00558 |
F8 S2 APARTMENT | 2075.83 | 2490.99 | 0.179 | 0.215 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 40.63 | 0.00558 |
F9 SW APARTMENT | 3569.05 | 4282.86 | 0.308 | 0.369 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 39.20 | 0.00558 |
F9 NW APARTMENT | 3527.08 | 4232.50 | 0.304 | 0.365 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 38.61 | 0.00558 |
F9 SE APARTMENT | 3060.81 | 3672.97 | 0.264 | 0.317 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 11:30:00 | 38.41 | 0.00558 |
F9 NE APARTMENT | 2889.20 | 3467.03 | 0.249 | 0.299 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 37.24 | 0.00558 |
F9 N1 APARTMENT | 2052.52 | 2463.02 | 0.177 | 0.212 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 37.11 | 0.00558 |
F9 N2 APARTMENT | 2044.85 | 2453.82 | 0.176 | 0.212 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 37.11 | 0.00558 |
F9 S1 APARTMENT | 2142.11 | 2570.54 | 0.185 | 0.222 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 40.80 | 0.00558 |
F9 S2 APARTMENT | 2147.77 | 2577.32 | 0.185 | 0.222 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 40.80 | 0.00558 |
T SW APARTMENT | 4207.20 | 5048.64 | 0.363 | 0.435 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:15:00 | 39.74 | 0.00558 |
T NW APARTMENT | 4131.98 | 4958.38 | 0.356 | 0.428 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 39.20 | 0.00558 |
T SE APARTMENT | 3646.82 | 4376.18 | 0.315 | 0.377 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 40.80 | 0.00558 |
T NE APARTMENT | 3369.49 | 4043.39 | 0.291 | 0.349 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 11:15:00 | 38.07 | 0.00558 |
T N1 APARTMENT | 2491.46 | 2989.75 | 0.215 | 0.258 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 37.61 | 0.00558 |
T N2 APARTMENT | 2478.85 | 2974.62 | 0.214 | 0.257 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:15:00 | 40.60 | 0.00558 |
T S1 APARTMENT | 2787.64 | 3345.17 | 0.240 | 0.289 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 40.80 | 0.00558 |
T S2 APARTMENT | 2793.03 | 3351.63 | 0.241 | 0.289 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 40.80 | 0.00558 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 1250.01 | 1500.02 | 0.061 | 0.074 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 0.50 | 0.00432 |
G NW APARTMENT | 1258.97 | 1510.77 | 0.062 | 0.074 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 0.50 | 0.00432 |
OFFICE | 1586.96 | 1904.35 | 0.078 | 0.093 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 18:45:00 | 0.50 | 0.00432 |
G NE APARTMENT | 1254.13 | 1504.96 | 0.061 | 0.074 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 0.50 | 0.00432 |
G N1 APARTMENT | 750.07 | 900.08 | 0.037 | 0.044 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 09:15:00 | 0.50 | 0.00432 |
G N2 APARTMENT | 749.99 | 899.99 | 0.037 | 0.044 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 09:15:00 | 0.50 | 0.00432 |
G S1 APARTMENT | 739.11 | 886.93 | 0.036 | 0.043 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 09:15:00 | 0.50 | 0.00432 |
G S2 APARTMENT | 746.15 | 895.38 | 0.037 | 0.044 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 09:15:00 | 0.50 | 0.00432 |
F2 SW APARTMENT | 1188.55 | 1426.26 | 0.058 | 0.070 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F2 NW APARTMENT | 1196.54 | 1435.85 | 0.059 | 0.070 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F2 SE APARTMENT | 1205.73 | 1446.88 | 0.059 | 0.071 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F2 NE APARTMENT | 1191.63 | 1429.96 | 0.058 | 0.070 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F2 N1 APARTMENT | 600.40 | 720.49 | 0.029 | 0.035 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F2 N2 APARTMENT | 600.32 | 720.38 | 0.029 | 0.035 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F2 S1 APARTMENT | 594.70 | 713.64 | 0.029 | 0.035 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F2 S2 APARTMENT | 596.18 | 715.42 | 0.029 | 0.035 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F3 SW APARTMENT | 1162.42 | 1394.90 | 0.057 | 0.068 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F3 NW APARTMENT | 1169.48 | 1403.38 | 0.057 | 0.069 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F3 SE APARTMENT | 1160.88 | 1393.06 | 0.057 | 0.068 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F3 NE APARTMENT | 1165.27 | 1398.32 | 0.057 | 0.069 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F3 N1 APARTMENT | 560.43 | 672.52 | 0.027 | 0.033 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F3 N2 APARTMENT | 560.36 | 672.43 | 0.027 | 0.033 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F3 S1 APARTMENT | 553.83 | 664.60 | 0.027 | 0.033 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F3 S2 APARTMENT | 554.03 | 664.84 | 0.027 | 0.033 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F4 SW APARTMENT | 1169.76 | 1403.71 | 0.057 | 0.069 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F4 NW APARTMENT | 1176.10 | 1411.32 | 0.058 | 0.069 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F4 SE APARTMENT | 1166.55 | 1399.86 | 0.057 | 0.069 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F4 NE APARTMENT | 1172.57 | 1407.09 | 0.057 | 0.069 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F4 N1 APARTMENT | 556.31 | 667.57 | 0.027 | 0.033 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F4 N2 APARTMENT | 556.25 | 667.50 | 0.027 | 0.033 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F4 S1 APARTMENT | 550.20 | 660.24 | 0.027 | 0.032 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F4 S2 APARTMENT | 550.18 | 660.22 | 0.027 | 0.032 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
M SW APARTMENT | 1162.88 | 1395.45 | 0.057 | 0.068 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
M NW APARTMENT | 1167.39 | 1400.86 | 0.057 | 0.069 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
M SE APARTMENT | 1160.04 | 1392.04 | 0.057 | 0.068 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
M NE APARTMENT | 1164.51 | 1397.42 | 0.057 | 0.068 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
M N1 APARTMENT | 541.86 | 650.23 | 0.027 | 0.032 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
M N2 APARTMENT | 541.81 | 650.17 | 0.027 | 0.032 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
M S1 APARTMENT | 537.54 | 645.04 | 0.026 | 0.032 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
M S2 APARTMENT | 537.49 | 644.99 | 0.026 | 0.032 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F6 SW APARTMENT | 1212.64 | 1455.17 | 0.059 | 0.071 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F6 NW APARTMENT | 1217.04 | 1460.45 | 0.060 | 0.072 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F6 SE APARTMENT | 1210.36 | 1452.44 | 0.059 | 0.071 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F6 NE APARTMENT | 1214.76 | 1457.71 | 0.060 | 0.071 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F6 N1 APARTMENT | 580.97 | 697.16 | 0.028 | 0.034 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F6 N2 APARTMENT | 580.93 | 697.11 | 0.028 | 0.034 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F6 S1 APARTMENT | 576.73 | 692.07 | 0.028 | 0.034 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F6 S2 APARTMENT | 576.69 | 692.02 | 0.028 | 0.034 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F7 SW APARTMENT | 1242.08 | 1490.49 | 0.061 | 0.073 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F7 NW APARTMENT | 1245.41 | 1494.50 | 0.061 | 0.073 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F7 SE APARTMENT | 1240.35 | 1488.42 | 0.061 | 0.073 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F7 NE APARTMENT | 1243.69 | 1492.43 | 0.061 | 0.073 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F7 N1 APARTMENT | 602.67 | 723.20 | 0.030 | 0.035 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F7 N2 APARTMENT | 602.64 | 723.17 | 0.030 | 0.035 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F7 S1 APARTMENT | 599.48 | 719.38 | 0.029 | 0.035 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F7 S2 APARTMENT | 599.45 | 719.34 | 0.029 | 0.035 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F8 SW APARTMENT | 1273.90 | 1528.69 | 0.062 | 0.075 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F8 NW APARTMENT | 1276.11 | 1531.33 | 0.063 | 0.075 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F8 SE APARTMENT | 1272.70 | 1527.23 | 0.062 | 0.075 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F8 NE APARTMENT | 1274.90 | 1529.88 | 0.062 | 0.075 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F8 N1 APARTMENT | 627.86 | 753.43 | 0.031 | 0.037 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F8 N2 APARTMENT | 627.84 | 753.41 | 0.031 | 0.037 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F8 S1 APARTMENT | 625.80 | 750.96 | 0.031 | 0.037 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F8 S2 APARTMENT | 625.78 | 750.93 | 0.031 | 0.037 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F9 SW APARTMENT | 1383.63 | 1660.35 | 0.068 | 0.081 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F9 NW APARTMENT | 1383.31 | 1659.98 | 0.068 | 0.081 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F9 SE APARTMENT | 1382.90 | 1659.48 | 0.068 | 0.081 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F9 NE APARTMENT | 1382.59 | 1659.10 | 0.068 | 0.081 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F9 N1 APARTMENT | 724.38 | 869.25 | 0.036 | 0.043 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F9 N2 APARTMENT | 724.36 | 869.24 | 0.036 | 0.043 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F9 S1 APARTMENT | 724.63 | 869.55 | 0.036 | 0.043 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
F9 S2 APARTMENT | 724.61 | 869.54 | 0.036 | 0.043 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
T SW APARTMENT | 1765.98 | 2119.18 | 0.087 | 0.104 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
T NW APARTMENT | 1768.60 | 2122.31 | 0.087 | 0.104 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
T SE APARTMENT | 1765.70 | 2118.84 | 0.087 | 0.104 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
T NE APARTMENT | 1768.31 | 2121.98 | 0.087 | 0.104 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
T N1 APARTMENT | 1139.76 | 1367.71 | 0.056 | 0.067 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
T N2 APARTMENT | 1139.75 | 1367.71 | 0.056 | 0.067 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
T S1 APARTMENT | 1136.38 | 1363.66 | 0.056 | 0.067 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
T S2 APARTMENT | 1136.38 | 1363.65 | 0.056 | 0.067 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 0.50 | 0.00432 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
AIRLOOP G SW | 0.31 | 0.31 | 0.07 | 0.07 |
AIRLOOP G NW | 0.31 | 0.31 | 0.07 | 0.07 |
AIRLOOP OFFICE | 0.37 | 0.37 | 0.09 | 0.09 |
AIRLOOP G NE | 0.24 | 0.24 | 0.07 | 0.07 |
AIRLOOP G N1 | 0.17 | 0.17 | 0.04 | 0.04 |
AIRLOOP G N2 | 0.16 | 0.16 | 0.04 | 0.04 |
AIRLOOP G S1 | 0.17 | 0.17 | 0.04 | 0.04 |
AIRLOOP G S2 | 0.18 | 0.18 | 0.04 | 0.04 |
AIRLOOP F2 SW | 0.36 | 0.36 | 0.07 | 0.07 |
AIRLOOP F2 NW | 0.35 | 0.35 | 0.07 | 0.07 |
AIRLOOP F2 SE | 0.32 | 0.32 | 0.07 | 0.07 |
AIRLOOP F2 NE | 0.29 | 0.29 | 0.07 | 0.07 |
AIRLOOP F2 N1 | 0.20 | 0.20 | 0.04 | 0.04 |
AIRLOOP F2 N2 | 0.19 | 0.19 | 0.04 | 0.04 |
AIRLOOP F2 S1 | 0.21 | 0.21 | 0.03 | 0.03 |
AIRLOOP F2 S2 | 0.21 | 0.21 | 0.04 | 0.04 |
AIRLOOP F3 SW | 0.36 | 0.36 | 0.07 | 0.07 |
AIRLOOP F3 NW | 0.35 | 0.35 | 0.07 | 0.07 |
AIRLOOP F3 SE | 0.31 | 0.31 | 0.07 | 0.07 |
AIRLOOP F3 NE | 0.29 | 0.29 | 0.07 | 0.07 |
AIRLOOP F3 N1 | 0.20 | 0.20 | 0.03 | 0.03 |
AIRLOOP F3 N2 | 0.20 | 0.20 | 0.03 | 0.03 |
AIRLOOP F3 S1 | 0.21 | 0.21 | 0.03 | 0.03 |
AIRLOOP F3 S2 | 0.21 | 0.21 | 0.03 | 0.03 |
AIRLOOP F4 SW | 0.36 | 0.36 | 0.07 | 0.07 |
AIRLOOP F4 NW | 0.35 | 0.35 | 0.07 | 0.07 |
AIRLOOP F4 SE | 0.31 | 0.31 | 0.07 | 0.07 |
AIRLOOP F4 NE | 0.29 | 0.29 | 0.07 | 0.07 |
AIRLOOP F4 N1 | 0.20 | 0.20 | 0.03 | 0.03 |
AIRLOOP F4 N2 | 0.20 | 0.20 | 0.03 | 0.03 |
AIRLOOP F4 S1 | 0.21 | 0.21 | 0.03 | 0.03 |
AIRLOOP F4 S2 | 0.21 | 0.21 | 0.03 | 0.03 |
AIRLOOP M SW | 0.36 | 0.36 | 0.07 | 0.07 |
AIRLOOP M NW | 0.36 | 0.36 | 0.07 | 0.07 |
AIRLOOP M SE | 0.31 | 0.31 | 0.07 | 0.07 |
AIRLOOP M NE | 0.30 | 0.30 | 0.07 | 0.07 |
AIRLOOP M N1 | 0.20 | 0.20 | 0.03 | 0.03 |
AIRLOOP M N2 | 0.20 | 0.20 | 0.03 | 0.03 |
AIRLOOP M S1 | 0.22 | 0.22 | 0.03 | 0.03 |
AIRLOOP M S2 | 0.22 | 0.22 | 0.03 | 0.03 |
AIRLOOP F6 SW | 0.36 | 0.36 | 0.07 | 0.07 |
AIRLOOP F6 NW | 0.35 | 0.35 | 0.07 | 0.07 |
AIRLOOP F6 SE | 0.31 | 0.31 | 0.07 | 0.07 |
AIRLOOP F6 NE | 0.29 | 0.29 | 0.07 | 0.07 |
AIRLOOP F6 N1 | 0.20 | 0.20 | 0.03 | 0.03 |
AIRLOOP F6 N2 | 0.20 | 0.20 | 0.03 | 0.03 |
AIRLOOP F6 S1 | 0.21 | 0.21 | 0.03 | 0.03 |
AIRLOOP F6 S2 | 0.21 | 0.21 | 0.03 | 0.03 |
AIRLOOP F7 SW | 0.36 | 0.36 | 0.07 | 0.07 |
AIRLOOP F7 NW | 0.35 | 0.35 | 0.07 | 0.07 |
AIRLOOP F7 SE | 0.31 | 0.31 | 0.07 | 0.07 |
AIRLOOP F7 NE | 0.29 | 0.29 | 0.07 | 0.07 |
AIRLOOP F7 N1 | 0.20 | 0.20 | 0.04 | 0.04 |
AIRLOOP F7 N2 | 0.20 | 0.20 | 0.04 | 0.04 |
AIRLOOP F7 S1 | 0.21 | 0.21 | 0.04 | 0.04 |
AIRLOOP F7 S2 | 0.21 | 0.21 | 0.04 | 0.04 |
AIRLOOP F8 SW | 0.36 | 0.36 | 0.07 | 0.07 |
AIRLOOP F8 NW | 0.35 | 0.35 | 0.08 | 0.08 |
AIRLOOP F8 SE | 0.31 | 0.31 | 0.07 | 0.07 |
AIRLOOP F8 NE | 0.29 | 0.29 | 0.07 | 0.07 |
AIRLOOP F8 N1 | 0.20 | 0.20 | 0.04 | 0.04 |
AIRLOOP F8 N2 | 0.20 | 0.20 | 0.04 | 0.04 |
AIRLOOP F8 S1 | 0.21 | 0.21 | 0.04 | 0.04 |
AIRLOOP F8 S2 | 0.21 | 0.21 | 0.04 | 0.04 |
AIRLOOP F9 SW | 0.37 | 0.37 | 0.08 | 0.08 |
AIRLOOP F9 NW | 0.37 | 0.37 | 0.08 | 0.08 |
AIRLOOP F9 SE | 0.32 | 0.32 | 0.08 | 0.08 |
AIRLOOP F9 NE | 0.30 | 0.30 | 0.08 | 0.08 |
AIRLOOP F9 N1 | 0.21 | 0.21 | 0.04 | 0.04 |
AIRLOOP F9 N2 | 0.21 | 0.21 | 0.04 | 0.04 |
AIRLOOP F9 S1 | 0.22 | 0.22 | 0.04 | 0.04 |
AIRLOOP F9 S2 | 0.22 | 0.22 | 0.04 | 0.04 |
AIRLOOP T SW | 0.44 | 0.44 | 0.10 | 0.10 |
AIRLOOP T NW | 0.43 | 0.43 | 0.10 | 0.10 |
AIRLOOP T SE | 0.38 | 0.38 | 0.10 | 0.10 |
AIRLOOP T NE | 0.35 | 0.35 | 0.10 | 0.10 |
AIRLOOP T N1 | 0.26 | 0.26 | 0.07 | 0.07 |
AIRLOOP T N2 | 0.26 | 0.26 | 0.07 | 0.07 |
AIRLOOP T S1 | 0.29 | 0.29 | 0.07 | 0.07 |
AIRLOOP T S2 | 0.29 | 0.29 | 0.07 | 0.07 |
Report: System Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:11
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 3222.25 | 3860.50 | 403.25 |
G NW APARTMENT | 2953.25 | 4943.50 | 425.00 |
OFFICE | 1060.75 | 233.00 | 4.00 |
G NE APARTMENT | 2955.75 | 4827.50 | 415.50 |
G N1 APARTMENT | 2769.00 | 5369.00 | 547.25 |
G N2 APARTMENT | 2769.25 | 5367.50 | 547.25 |
G S1 APARTMENT | 2953.75 | 4165.00 | 480.50 |
G S2 APARTMENT | 2971.00 | 4094.75 | 473.00 |
F2 SW APARTMENT | 4140.25 | 1879.00 | 296.25 |
F2 NW APARTMENT | 3420.50 | 3676.25 | 318.00 |
F2 SE APARTMENT | 4338.00 | 1703.50 | 271.00 |
F2 NE APARTMENT | 3428.75 | 3631.75 | 302.75 |
F2 N1 APARTMENT | 3128.00 | 3977.75 | 408.00 |
F2 N2 APARTMENT | 3128.00 | 3976.50 | 407.00 |
F2 S1 APARTMENT | 3949.00 | 1638.75 | 349.75 |
F2 S2 APARTMENT | 3967.75 | 1616.75 | 347.00 |
F3 SW APARTMENT | 4422.25 | 1513.00 | 293.25 |
F3 NW APARTMENT | 3518.00 | 3304.75 | 318.25 |
F3 SE APARTMENT | 4483.25 | 1510.75 | 281.50 |
F3 NE APARTMENT | 3548.50 | 3325.25 | 302.75 |
F3 N1 APARTMENT | 3266.25 | 3546.00 | 400.00 |
F3 N2 APARTMENT | 3265.00 | 3555.00 | 399.75 |
F3 S1 APARTMENT | 4317.00 | 1143.75 | 333.75 |
F3 S2 APARTMENT | 4319.75 | 1141.00 | 332.00 |
F4 SW APARTMENT | 4430.25 | 1469.25 | 295.75 |
F4 NW APARTMENT | 3525.50 | 3215.50 | 319.25 |
F4 SE APARTMENT | 4466.75 | 1496.75 | 287.75 |
F4 NE APARTMENT | 3550.00 | 3250.00 | 307.50 |
F4 N1 APARTMENT | 3297.50 | 3399.50 | 397.25 |
F4 N2 APARTMENT | 3298.00 | 3404.50 | 397.00 |
F4 S1 APARTMENT | 4367.00 | 1052.00 | 323.50 |
F4 S2 APARTMENT | 4366.75 | 1050.75 | 322.00 |
M SW APARTMENT | 4455.50 | 1439.75 | 294.25 |
M NW APARTMENT | 3548.75 | 3157.75 | 317.50 |
M SE APARTMENT | 4484.00 | 1465.00 | 285.75 |
M NE APARTMENT | 3575.00 | 3193.75 | 304.00 |
M N1 APARTMENT | 3343.75 | 3295.75 | 386.25 |
M N2 APARTMENT | 3342.50 | 3300.75 | 385.00 |
M S1 APARTMENT | 4412.25 | 999.00 | 313.25 |
M S2 APARTMENT | 4412.00 | 999.50 | 311.50 |
F6 SW APARTMENT | 4263.75 | 1630.50 | 311.25 |
F6 NW APARTMENT | 3433.25 | 3346.00 | 332.75 |
F6 SE APARTMENT | 4295.75 | 1636.25 | 301.50 |
F6 NE APARTMENT | 3460.50 | 3382.00 | 322.25 |
F6 N1 APARTMENT | 3235.75 | 3490.50 | 404.00 |
F6 N2 APARTMENT | 3233.50 | 3501.25 | 403.75 |
F6 S1 APARTMENT | 4211.00 | 1175.00 | 335.50 |
F6 S2 APARTMENT | 4213.25 | 1177.50 | 334.25 |
F7 SW APARTMENT | 4147.50 | 1756.25 | 320.50 |
F7 NW APARTMENT | 3370.75 | 3473.50 | 341.25 |
F7 SE APARTMENT | 4173.00 | 1765.25 | 311.75 |
F7 NE APARTMENT | 3398.75 | 3485.00 | 328.50 |
F7 N1 APARTMENT | 3182.00 | 3620.00 | 414.50 |
F7 N2 APARTMENT | 3179.50 | 3628.00 | 413.50 |
F7 S1 APARTMENT | 4096.00 | 1301.50 | 348.50 |
F7 S2 APARTMENT | 4099.25 | 1302.50 | 348.25 |
F8 SW APARTMENT | 4054.75 | 1865.25 | 324.50 |
F8 NW APARTMENT | 3333.00 | 3567.25 | 345.00 |
F8 SE APARTMENT | 4087.25 | 1873.50 | 314.00 |
F8 NE APARTMENT | 3366.75 | 3570.00 | 331.25 |
F8 N1 APARTMENT | 3134.75 | 3718.75 | 416.00 |
F8 N2 APARTMENT | 3134.50 | 3724.75 | 414.25 |
F8 S1 APARTMENT | 4000.50 | 1410.00 | 353.00 |
F8 S2 APARTMENT | 4004.25 | 1412.75 | 352.75 |
F9 SW APARTMENT | 3989.75 | 2053.75 | 322.25 |
F9 NW APARTMENT | 3348.50 | 3681.25 | 338.25 |
F9 SE APARTMENT | 4021.25 | 2034.50 | 309.75 |
F9 NE APARTMENT | 3373.50 | 3660.25 | 327.00 |
F9 N1 APARTMENT | 3138.75 | 3817.50 | 403.75 |
F9 N2 APARTMENT | 3139.75 | 3822.00 | 402.75 |
F9 S1 APARTMENT | 3885.00 | 1642.00 | 348.25 |
F9 S2 APARTMENT | 3886.75 | 1645.50 | 348.25 |
T SW APARTMENT | 4399.25 | 2898.50 | 362.00 |
T NW APARTMENT | 3693.00 | 3843.75 | 403.75 |
T SE APARTMENT | 4517.25 | 2808.00 | 349.00 |
T NE APARTMENT | 3788.50 | 3835.50 | 394.25 |
T N1 APARTMENT | 3498.25 | 4053.25 | 423.25 |
T N2 APARTMENT | 3502.00 | 4041.00 | 415.25 |
T S1 APARTMENT | 4309.00 | 2660.00 | 375.00 |
T S2 APARTMENT | 4317.75 | 2662.00 | 375.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 5444.50 | 5420.75 | 627.50 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 0.00 | 68.50 | 0.00 | 68.50 |
G NW APARTMENT | 0.00 | 74.25 | 0.00 | 74.25 |
OFFICE | 0.25 | 28.00 | 0.00 | 25.50 |
G NE APARTMENT | 0.00 | 32.00 | 0.00 | 32.00 |
G N1 APARTMENT | 2.00 | 83.00 | 2.00 | 83.00 |
G N2 APARTMENT | 4.25 | 82.75 | 4.25 | 82.75 |
G S1 APARTMENT | 0.00 | 227.75 | 0.00 | 227.75 |
G S2 APARTMENT | 0.00 | 197.00 | 0.00 | 197.00 |
F2 SW APARTMENT | 0.00 | 87.75 | 0.00 | 87.75 |
F2 NW APARTMENT | 0.00 | 69.00 | 0.00 | 69.00 |
F2 SE APARTMENT | 0.00 | 75.50 | 0.00 | 75.50 |
F2 NE APARTMENT | 0.00 | 30.50 | 0.00 | 30.50 |
F2 N1 APARTMENT | 0.50 | 83.00 | 0.50 | 83.00 |
F2 N2 APARTMENT | 0.50 | 84.75 | 0.50 | 84.75 |
F2 S1 APARTMENT | 0.00 | 352.00 | 0.00 | 352.00 |
F2 S2 APARTMENT | 0.00 | 338.50 | 0.00 | 338.50 |
F3 SW APARTMENT | 0.00 | 124.00 | 0.00 | 124.00 |
F3 NW APARTMENT | 0.00 | 75.25 | 0.00 | 75.25 |
F3 SE APARTMENT | 0.00 | 141.75 | 0.00 | 141.75 |
F3 NE APARTMENT | 0.00 | 38.00 | 0.00 | 38.00 |
F3 N1 APARTMENT | 0.25 | 99.50 | 0.25 | 99.50 |
F3 N2 APARTMENT | 0.25 | 100.75 | 0.25 | 100.75 |
F3 S1 APARTMENT | 0.00 | 404.00 | 0.00 | 404.00 |
F3 S2 APARTMENT | 0.00 | 399.50 | 0.00 | 399.50 |
F4 SW APARTMENT | 0.00 | 130.00 | 0.00 | 130.00 |
F4 NW APARTMENT | 0.00 | 80.75 | 0.00 | 80.75 |
F4 SE APARTMENT | 0.00 | 152.75 | 0.00 | 152.75 |
F4 NE APARTMENT | 0.00 | 45.25 | 0.00 | 45.25 |
F4 N1 APARTMENT | 0.50 | 104.50 | 0.50 | 104.50 |
F4 N2 APARTMENT | 0.50 | 105.25 | 0.50 | 105.25 |
F4 S1 APARTMENT | 0.00 | 404.25 | 0.00 | 404.25 |
F4 S2 APARTMENT | 0.00 | 402.00 | 0.00 | 402.00 |
M SW APARTMENT | 0.00 | 129.75 | 0.00 | 129.75 |
M NW APARTMENT | 0.00 | 83.00 | 0.00 | 83.00 |
M SE APARTMENT | 0.00 | 141.25 | 0.00 | 141.25 |
M NE APARTMENT | 0.00 | 53.00 | 0.00 | 53.00 |
M N1 APARTMENT | 0.50 | 107.50 | 0.50 | 107.50 |
M N2 APARTMENT | 0.50 | 107.50 | 0.50 | 107.50 |
M S1 APARTMENT | 0.00 | 392.00 | 0.00 | 392.00 |
M S2 APARTMENT | 0.00 | 389.75 | 0.00 | 389.75 |
F6 SW APARTMENT | 0.00 | 122.25 | 0.00 | 122.25 |
F6 NW APARTMENT | 0.00 | 88.25 | 0.00 | 88.25 |
F6 SE APARTMENT | 0.00 | 135.75 | 0.00 | 135.75 |
F6 NE APARTMENT | 0.00 | 60.75 | 0.00 | 60.75 |
F6 N1 APARTMENT | 1.00 | 111.00 | 1.00 | 111.00 |
F6 N2 APARTMENT | 1.00 | 111.50 | 1.00 | 111.50 |
F6 S1 APARTMENT | 0.00 | 382.00 | 0.00 | 382.00 |
F6 S2 APARTMENT | 0.00 | 381.25 | 0.00 | 381.25 |
F7 SW APARTMENT | 0.00 | 117.25 | 0.00 | 117.25 |
F7 NW APARTMENT | 0.00 | 88.25 | 0.00 | 88.25 |
F7 SE APARTMENT | 0.00 | 131.75 | 0.00 | 131.75 |
F7 NE APARTMENT | 0.00 | 67.75 | 0.00 | 67.75 |
F7 N1 APARTMENT | 0.00 | 113.75 | 0.00 | 113.75 |
F7 N2 APARTMENT | 0.75 | 116.00 | 0.75 | 116.00 |
F7 S1 APARTMENT | 0.00 | 370.00 | 0.00 | 370.00 |
F7 S2 APARTMENT | 0.00 | 366.50 | 0.00 | 366.50 |
F8 SW APARTMENT | 0.00 | 111.75 | 0.00 | 111.75 |
F8 NW APARTMENT | 0.00 | 89.25 | 0.00 | 89.25 |
F8 SE APARTMENT | 0.00 | 127.25 | 0.00 | 127.25 |
F8 NE APARTMENT | 0.00 | 73.50 | 0.00 | 73.50 |
F8 N1 APARTMENT | 0.75 | 116.25 | 0.75 | 116.25 |
F8 N2 APARTMENT | 0.50 | 117.00 | 0.50 | 117.00 |
F8 S1 APARTMENT | 0.00 | 347.75 | 0.00 | 347.75 |
F8 S2 APARTMENT | 0.00 | 341.75 | 0.00 | 341.75 |
F9 SW APARTMENT | 0.00 | 99.50 | 0.00 | 99.50 |
F9 NW APARTMENT | 0.00 | 84.75 | 0.00 | 84.75 |
F9 SE APARTMENT | 0.00 | 122.75 | 0.00 | 122.75 |
F9 NE APARTMENT | 0.00 | 86.75 | 0.00 | 86.75 |
F9 N1 APARTMENT | 0.00 | 110.00 | 0.00 | 110.00 |
F9 N2 APARTMENT | 0.00 | 111.50 | 0.00 | 111.50 |
F9 S1 APARTMENT | 0.00 | 283.25 | 0.00 | 283.25 |
F9 S2 APARTMENT | 0.00 | 281.50 | 0.00 | 281.50 |
T SW APARTMENT | 0.00 | 98.50 | 0.00 | 98.50 |
T NW APARTMENT | 0.00 | 78.25 | 0.00 | 78.25 |
T SE APARTMENT | 0.00 | 87.25 | 0.00 | 87.25 |
T NE APARTMENT | 0.00 | 69.00 | 0.00 | 69.00 |
T N1 APARTMENT | 0.00 | 117.75 | 0.00 | 117.75 |
T N2 APARTMENT | 0.00 | 94.00 | 0.00 | 94.00 |
T S1 APARTMENT | 0.00 | 183.00 | 0.00 | 183.00 |
T S2 APARTMENT | 0.00 | 181.50 | 0.00 | 181.50 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 11.00 | 642.50 | 10.75 | 640.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:11
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.079 | 0.000 | 0.347 |
G NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.079 | 0.000 | 0.320 |
OFFICE | 0.94 | 1.00 | 268.96 | 0.521 | 0.083 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.079 | 0.000 | 0.321 |
G N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.048 | 0.000 | 0.309 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.048 | 0.000 | 0.309 |
G S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.048 | 0.000 | 0.344 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.048 | 0.000 | 0.344 |
F2 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.114 | 0.000 | 0.393 |
F2 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.114 | 0.000 | 0.367 |
F2 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.114 | 0.000 | 0.393 |
F2 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.114 | 0.000 | 0.366 |
F2 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.069 | 0.000 | 0.359 |
F2 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.069 | 0.000 | 0.359 |
F2 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.069 | 0.000 | 0.392 |
F2 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.069 | 0.000 | 0.392 |
F3 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.135 | 0.000 | 0.419 |
F3 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.135 | 0.000 | 0.392 |
F3 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.135 | 0.000 | 0.420 |
F3 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.135 | 0.000 | 0.391 |
F3 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.081 | 0.000 | 0.386 |
F3 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.081 | 0.000 | 0.386 |
F3 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.081 | 0.000 | 0.419 |
F3 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.081 | 0.000 | 0.419 |
F4 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.151 | 0.000 | 0.440 |
F4 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.151 | 0.000 | 0.410 |
F4 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.151 | 0.000 | 0.440 |
F4 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.151 | 0.000 | 0.409 |
F4 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.091 | 0.000 | 0.405 |
F4 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.091 | 0.000 | 0.405 |
F4 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.091 | 0.000 | 0.440 |
F4 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.091 | 0.000 | 0.440 |
M SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.164 | 0.000 | 0.458 |
M NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.164 | 0.000 | 0.426 |
M SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.164 | 0.000 | 0.458 |
M NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.164 | 0.000 | 0.425 |
M N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.099 | 0.000 | 0.421 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.099 | 0.000 | 0.421 |
M S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.099 | 0.000 | 0.458 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.099 | 0.000 | 0.458 |
F6 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.175 | 0.000 | 0.477 |
F6 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.175 | 0.000 | 0.441 |
F6 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.175 | 0.000 | 0.477 |
F6 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.175 | 0.000 | 0.441 |
F6 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.105 | 0.000 | 0.437 |
F6 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.105 | 0.000 | 0.437 |
F6 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.106 | 0.000 | 0.477 |
F6 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.106 | 0.000 | 0.477 |
F7 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.185 | 0.000 | 0.491 |
F7 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.185 | 0.000 | 0.453 |
F7 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.185 | 0.000 | 0.491 |
F7 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.185 | 0.000 | 0.453 |
F7 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.111 | 0.000 | 0.449 |
F7 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.111 | 0.000 | 0.449 |
F7 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.112 | 0.000 | 0.491 |
F7 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.112 | 0.000 | 0.491 |
F8 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.194 | 0.000 | 0.504 |
F8 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.194 | 0.000 | 0.464 |
F8 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.194 | 0.000 | 0.504 |
F8 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.194 | 0.000 | 0.463 |
F8 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.117 | 0.000 | 0.459 |
F8 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.117 | 0.000 | 0.459 |
F8 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.117 | 0.000 | 0.504 |
F8 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.117 | 0.000 | 0.504 |
F9 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.202 | 0.000 | 0.516 |
F9 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.202 | 0.000 | 0.473 |
F9 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.202 | 0.000 | 0.516 |
F9 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.202 | 0.000 | 0.473 |
F9 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.122 | 0.000 | 0.468 |
F9 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.122 | 0.000 | 0.468 |
F9 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.122 | 0.000 | 0.515 |
F9 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.122 | 0.000 | 0.515 |
T SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.209 | 0.000 | 0.526 |
T NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.209 | 0.000 | 0.483 |
T SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.209 | 0.000 | 0.526 |
T NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.209 | 0.000 | 0.484 |
T N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.126 | 0.000 | 0.478 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.126 | 0.000 | 0.478 |
T S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.126 | 0.000 | 0.525 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.126 | 0.000 | 0.525 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.96 | 0.510 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
F2 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F2 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F2 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F2 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F2 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F2 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
F2 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.349 | 0.000 | 0.000 | 0.000 |
F2 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
F3 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.349 | 0.000 | 0.000 | 0.000 |
F3 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F3 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F3 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F3 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F3 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
F3 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.349 | 0.000 | 0.000 | 0.000 |
F3 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
F4 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.349 | 0.000 | 0.000 | 0.000 |
F4 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F4 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F4 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F4 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F4 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
F4 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.349 | 0.000 | 0.000 | 0.000 |
F4 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.349 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.349 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.349 | 0.000 | 0.000 | 0.000 |
F6 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F6 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F6 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F6 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F6 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F6 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
F6 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F6 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
F7 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F7 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F7 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F7 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F7 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F7 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
F7 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F7 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
F8 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F8 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F8 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F8 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F8 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F8 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
F8 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F8 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
F9 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F9 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F9 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F9 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F9 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F9 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
F9 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F9 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.346 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.346 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.346 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:11
Surfaces by ClassTotal | Outdoors | |
Wall | 420 | 140 |
Floor | 90 | 9 |
Roof | 90 | 9 |
Internal Mass | 80 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 140 | 140 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 80 |
Conditioned Zones | 80 |
Unconditioned Zones | 10 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 4197 |
Defaulted Fields | 814 |
Fields with Defaults | 11307 |
Autosized Fields | 1293 |
Autosizable Fields | 1630 |
Autocalculated Fields | 907 |
Autocalculatable Fields | 1710 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2018-10-19 09:40:11
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 3505.44 | 62361.99 | 09-JAN-03:15 | 186660.91 | 16-JUN-19:30 |
Electricity:Building | 1547.51 | 26803.46 | 01-JAN-03:15 | 79071.91 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity | 416.41 | 7980.64 | 01-JAN-00:15 | 25049.15 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 348.50 | 6974.01 | 01-JAN-00:15 | 20603.34 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 29.50 | 508.27 | 01-JAN-00:15 | 2167.24 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 21.95 | 379.58 | 01-JAN-00:15 | 1622.33 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
Electricity:Zone:F2 SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F2 NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F2 SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F2 NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F2 N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F2 N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F2 S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F2 S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F2 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F2 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
Electricity:Zone:F3 SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F3 NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F3 SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F3 NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F3 N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F3 N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F3 S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F3 S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F3 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F3 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
Electricity:Zone:F4 SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F4 NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F4 SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F4 NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F4 N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F4 N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F4 S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F4 S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F4 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F4 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
Electricity:Zone:M SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:M CORRIDOR | 37.06 | 1175.12 | 01-JAN-00:15 | 1175.12 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 37.06 | 1175.12 | 01-JAN-00:15 | 1175.12 | 01-JAN-00:15 |
Electricity:Zone:F6 SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F6 NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F6 SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F6 NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F6 N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F6 N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F6 S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F6 S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F6 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F6 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
Electricity:Zone:F7 SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F7 NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F7 SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F7 NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F7 N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F7 N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F7 S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F7 S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F7 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F7 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
Electricity:Zone:F8 SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F8 NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F8 SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F8 NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F8 N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F8 N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F8 S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F8 S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F8 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F8 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
Electricity:Zone:F9 SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F9 NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F9 SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F9 NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F9 N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F9 N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F9 S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F9 S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:F9 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F9 CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
Electricity:Zone:T SW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 14.63 | 238.08 | 01-JAN-03:15 | 783.07 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 2.41 | 14.40 | 01-JAN-00:15 | 230.46 | 01-JAN-19:15 |
Electricity:Zone:T CORRIDOR | 177.27 | 1611.36 | 01-JAN-00:15 | 10825.51 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 18.53 | 587.56 | 01-JAN-00:15 | 587.56 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 67.92 | 1006.63 | 01-JAN-00:15 | 4445.81 | 01-JAN-19:15 |
InteriorEquipment:Electricity | 1131.09 | 18822.82 | 01-JAN-03:15 | 56933.81 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 1131.09 | 18822.82 | 01-JAN-03:15 | 56933.81 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 7.55 | 128.69 | 01-JAN-00:15 | 544.91 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T CORRIDOR | 158.74 | 1023.79 | 01-JAN-00:15 | 10237.95 | 01-JAN-07:15 |
Fans:Electricity | 770.14 | 24420.97 | 02-JAN-14:30 | 24420.97 | 01-JAN-00:15 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Electricity:HVAC | 1703.75 | 24801.50 | 09-JAN-03:15 | 102266.84 | 28-JUN-16:15 |
ElectricityProduced:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityProduced:HVAC | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricityProduced | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 3505.44 | 62361.99 | 09-JAN-03:15 | 186660.91 | 16-JUN-19:30 |
ElectricityPurchased:Plant | 3505.44 | 62361.99 | 09-JAN-03:15 | 186660.91 | 16-JUN-19:30 |
Cogeneration:ElectricityPurchased | 3505.44 | 62361.99 | 09-JAN-03:15 | 186660.91 | 16-JUN-19:30 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 3505.44 | 62361.99 | 09-JAN-03:15 | 186660.91 | 16-JUN-19:30 |
ElectricityNet:Plant | 3505.44 | 62361.99 | 09-JAN-03:15 | 186660.91 | 16-JUN-19:30 |
Cogeneration:ElectricityNet | 3505.44 | 62361.99 | 09-JAN-03:15 | 186660.91 | 16-JUN-19:30 |
ExteriorLights:Electricity | 168.51 | 0.00 | 01-JAN-07:30 | 10720.10 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 168.51 | 0.00 | 01-JAN-07:30 | 10720.10 | 01-JAN-00:15 |
General:Fans:Electricity | 770.14 | 24420.97 | 02-JAN-14:30 | 24420.97 | 01-JAN-00:15 |
Cooling:Electricity | 908.06 | 0.00 | 01-JAN-00:15 | 76799.83 | 28-JUN-15:15 |
Heating:Electricity | 4.73 | 0.00 | 01-JAN-12:00 | 16309.45 | 07-DEC-05:00 |
Electricity:Plant | 85.67 | 36.93 | 02-JAN-18:45 | 4617.90 | 17-JUN-16:00 |
HeatRejection:Electricity | 33.55 | 0.00 | 01-JAN-00:15 | 2920.35 | 17-JUN-16:00 |
Boiler Parasitic:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Pumps:Electricity | 52.12 | 36.93 | 02-JAN-18:45 | 1697.55 | 01-JAN-00:15 |
WIRED_LTG_ELECTRICITY | 0.62 | 0.00 | 01-JAN-00:15 | 37.57 | 01-JAN-19:30 |
WIRED_INT_EQUIP | 973.17 | 1018.50 | 01-JAN-00:15 | 10185.00 | 01-JAN-07:15 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 901.91 | 9260.51 | 01-JAN-00:15 | 105770.42 | 17-DEC-07:30 |
Gas:Plant | 901.91 | 9260.51 | 01-JAN-00:15 | 105770.42 | 17-DEC-07:30 |
WaterSystems:Gas | 899.03 | 9260.51 | 01-JAN-00:15 | 81305.76 | 25-JAN-08:00 |
Water Heater:WaterSystems:Gas | 899.03 | 9260.51 | 01-JAN-00:15 | 81305.76 | 25-JAN-08:00 |
Heating:Gas | 2.88 | 0.00 | 01-JAN-00:15 | 54020.71 | 07-DEC-05:00 |
Boiler:Heating:Gas | 2.88 | 0.00 | 01-JAN-00:15 | 54020.71 | 07-DEC-05:00 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
PlantLoopCoolingDemand:Facility | 3685.13 | 0.00 | 01-JAN-00:15 | 348718.55 | 13-JUL-18:45 |
PlantLoopCoolingDemand:HVAC | 3685.13 | 0.00 | 01-JAN-00:15 | 348718.55 | 13-JUL-18:45 |
CoolingCoils:PlantLoopCoolingDemand | 3685.13 | 0.00 | 01-JAN-00:15 | 348718.55 | 13-JUL-18:45 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 8068.70 | 0.00 | 01-JAN-02:30 | 0.00 | 28-JUN-17:30 |
Water:Plant | 8068.70 | 0.00 | 01-JAN-02:30 | 0.00 | 28-JUN-17:30 |
WaterSystems:Water | 4778.51 | 0.00 | 01-JAN-02:30 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:Water | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
MainsWater:Facility | 8068.70 | 0.00 | 01-JAN-02:30 | 0.00 | 28-JUN-17:30 |
MainsWater:Plant | 8068.70 | 0.00 | 01-JAN-02:30 | 0.00 | 28-JUN-17:30 |
WaterSystems:MainsWater | 4778.51 | 0.00 | 01-JAN-02:30 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:MainsWater | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
sub cat:WaterSystems:Water | 4778.51 | 0.00 | 01-JAN-02:30 | 0.00 | 01-JAN-07:15 |
sub cat:WaterSystems:MainsWater | 4778.51 | 0.00 | 01-JAN-02:30 | 0.00 | 01-JAN-07:15 |
HeatRejection:Water | 3290.19 | 0.00 | 01-JAN-00:15 | 0.00 | 16-JUN-16:00 |
HeatRejection:MainsWater | 3290.19 | 0.00 | 01-JAN-00:15 | 0.00 | 16-JUN-16:00 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 693.51 | 344.92 | 25-JUL-01:15 | 85061.42 | 07-DEC-06:15 |
PlantLoopHeatingDemand:Plant | 681.09 | 344.92 | 25-JUL-01:15 | 48967.99 | 20-JAN-07:15 |
WaterSystems:PlantLoopHeatingDemand | 681.09 | 344.92 | 25-JUL-01:15 | 48967.99 | 20-JAN-07:15 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 5765.03 | 5980.57 | 18-FEB-02:15 | 508424.07 | 28-JUN-17:30 |
EnergyTransfer:Building | 2233.08 | 3977.63 | 08-MAR-19:30 | 215585.48 | 22-JUL-17:30 |
EnergyTransfer:Zone:G SW APARTMENT | 24.65 | 0.01 | 19-MAR-06:00 | 3278.77 | 01-NOV-15:15 |
Heating:EnergyTransfer | 56.29 | 0.00 | 27-JAN-13:45 | 37935.08 | 07-DEC-05:00 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 1.00 | 0.00 | 01-JAN-08:30 | 680.76 | 07-DEC-05:00 |
Cooling:EnergyTransfer | 2176.79 | 0.00 | 02-JAN-18:30 | 215585.48 | 22-JUL-17:30 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 23.65 | 0.00 | 01-JAN-00:15 | 3278.77 | 01-NOV-15:15 |
EnergyTransfer:Zone:G NW APARTMENT | 19.76 | 0.00 | 31-JAN-03:15 | 3160.46 | 28-JUN-17:30 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 1.98 | 0.00 | 01-JAN-20:45 | 941.84 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 17.78 | 0.00 | 01-JAN-00:15 | 3160.46 | 28-JUN-17:30 |
EnergyTransfer:Zone:OFFICE | 31.40 | 0.01 | 19-MAR-00:45 | 3820.06 | 28-SEP-10:00 |
Heating:EnergyTransfer:Zone:OFFICE | 0.57 | 0.00 | 01-JAN-08:00 | 726.33 | 07-DEC-06:00 |
Cooling:EnergyTransfer:Zone:OFFICE | 30.83 | 0.00 | 01-JAN-00:15 | 3820.06 | 28-SEP-10:00 |
EnergyTransfer:Zone:G NE APARTMENT | 19.52 | 0.02 | 14-MAR-24:00 | 2517.75 | 28-JUN-08:45 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 1.49 | 0.00 | 01-JAN-08:45 | 951.85 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 18.03 | 0.00 | 01-JAN-00:15 | 2517.75 | 28-JUN-08:45 |
EnergyTransfer:Zone:G N1 APARTMENT | 13.19 | 0.01 | 30-APR-04:45 | 1684.11 | 19-JUN-19:00 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 0.72 | 0.00 | 01-JAN-11:00 | 641.12 | 07-DEC-16:00 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 12.48 | 0.00 | 01-JAN-00:15 | 1684.11 | 19-JUN-19:00 |
EnergyTransfer:Zone:G N2 APARTMENT | 13.21 | 0.03 | 21-OCT-03:45 | 1671.71 | 19-JUN-19:00 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 0.71 | 0.00 | 01-JAN-11:00 | 643.82 | 07-DEC-16:00 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 12.50 | 0.00 | 01-JAN-00:15 | 1671.71 | 19-JUN-19:00 |
EnergyTransfer:Zone:G S1 APARTMENT | 18.45 | 0.01 | 12-NOV-03:45 | 2009.42 | 02-NOV-13:30 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.17 | 0.00 | 01-JAN-00:15 | 423.45 | 10-FEB-12:30 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 18.28 | 0.00 | 02-JAN-10:30 | 2009.42 | 02-NOV-13:30 |
EnergyTransfer:Zone:G S2 APARTMENT | 18.71 | 0.03 | 28-MAY-01:00 | 2059.80 | 02-NOV-13:30 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.18 | 0.00 | 01-JAN-00:15 | 367.50 | 10-FEB-12:30 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 18.53 | 0.00 | 02-JAN-10:30 | 2059.80 | 02-NOV-13:30 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F2 SW APARTMENT | 34.89 | 0.03 | 05-FEB-01:30 | 3875.81 | 01-NOV-15:15 |
Heating:EnergyTransfer:Zone:F2 SW APARTMENT | 0.54 | 0.00 | 01-JAN-00:15 | 402.05 | 16-MAR-07:45 |
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT | 34.35 | 0.00 | 02-JAN-10:30 | 3875.81 | 01-NOV-15:15 |
EnergyTransfer:Zone:F2 NW APARTMENT | 26.59 | 0.00 | 18-JAN-03:00 | 3631.92 | 28-JUN-17:45 |
Heating:EnergyTransfer:Zone:F2 NW APARTMENT | 1.45 | 0.00 | 01-JAN-16:15 | 834.00 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT | 25.14 | 0.00 | 01-JAN-00:15 | 3631.92 | 28-JUN-17:45 |
EnergyTransfer:Zone:F2 SE APARTMENT | 36.73 | 0.00 | 04-MAR-17:00 | 3466.27 | 28-SEP-10:15 |
Heating:EnergyTransfer:Zone:F2 SE APARTMENT | 0.35 | 0.00 | 01-JAN-00:15 | 347.34 | 07-NOV-09:15 |
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT | 36.38 | 0.00 | 02-JAN-18:00 | 3466.27 | 28-SEP-10:15 |
EnergyTransfer:Zone:F2 NE APARTMENT | 26.74 | 0.01 | 19-MAR-02:30 | 2970.48 | 28-JUN-08:30 |
Heating:EnergyTransfer:Zone:F2 NE APARTMENT | 0.95 | 0.00 | 01-JAN-08:30 | 845.76 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT | 25.79 | 0.00 | 01-JAN-00:15 | 2970.48 | 28-JUN-08:30 |
EnergyTransfer:Zone:F2 N1 APARTMENT | 19.06 | 0.07 | 17-DEC-13:30 | 1995.00 | 20-JUN-18:45 |
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT | 0.41 | 0.00 | 01-JAN-00:15 | 498.73 | 07-DEC-16:00 |
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT | 18.65 | 0.00 | 01-JAN-01:00 | 1995.00 | 20-JUN-18:45 |
EnergyTransfer:Zone:F2 N2 APARTMENT | 19.09 | 0.05 | 23-MAR-10:00 | 1985.63 | 20-JUN-18:45 |
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT | 0.41 | 0.00 | 01-JAN-00:15 | 501.80 | 07-DEC-16:00 |
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT | 18.68 | 0.00 | 01-JAN-00:45 | 1985.63 | 20-JUN-18:45 |
EnergyTransfer:Zone:F2 S1 APARTMENT | 27.84 | 0.11 | 25-NOV-15:15 | 2427.33 | 02-NOV-13:30 |
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT | 0.11 | 0.00 | 01-JAN-00:15 | 157.71 | 10-FEB-13:45 |
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT | 27.73 | 0.00 | 02-JAN-10:30 | 2427.33 | 02-NOV-13:30 |
EnergyTransfer:Zone:F2 S2 APARTMENT | 27.97 | 0.09 | 01-MAR-13:00 | 2444.97 | 02-NOV-13:30 |
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT | 0.12 | 0.00 | 01-JAN-00:15 | 161.46 | 10-FEB-13:45 |
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT | 27.86 | 0.00 | 02-JAN-10:30 | 2444.97 | 02-NOV-13:30 |
EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F3 SW APARTMENT | 36.36 | 0.06 | 21-APR-01:30 | 3880.04 | 01-NOV-15:15 |
Heating:EnergyTransfer:Zone:F3 SW APARTMENT | 0.45 | 0.00 | 01-JAN-00:15 | 447.56 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT | 35.91 | 0.00 | 02-JAN-10:30 | 3880.04 | 01-NOV-15:15 |
EnergyTransfer:Zone:F3 NW APARTMENT | 27.52 | 0.03 | 15-NOV-05:30 | 3628.96 | 22-JUL-17:30 |
Heating:EnergyTransfer:Zone:F3 NW APARTMENT | 1.24 | 0.00 | 01-JAN-16:15 | 794.42 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT | 26.28 | 0.00 | 01-JAN-00:15 | 3628.96 | 22-JUL-17:30 |
EnergyTransfer:Zone:F3 SE APARTMENT | 37.23 | 0.01 | 27-JAN-01:45 | 3303.70 | 09-OCT-10:45 |
Heating:EnergyTransfer:Zone:F3 SE APARTMENT | 0.29 | 0.00 | 01-JAN-00:15 | 328.29 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT | 36.94 | 0.00 | 02-JAN-18:15 | 3303.70 | 09-OCT-10:45 |
EnergyTransfer:Zone:F3 NE APARTMENT | 27.86 | 0.01 | 28-OCT-00:45 | 2975.03 | 28-JUN-08:30 |
Heating:EnergyTransfer:Zone:F3 NE APARTMENT | 0.83 | 0.00 | 01-JAN-08:30 | 804.21 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT | 27.04 | 0.00 | 01-JAN-00:15 | 2975.03 | 28-JUN-08:30 |
EnergyTransfer:Zone:F3 N1 APARTMENT | 20.33 | 0.03 | 07-DEC-00:45 | 2003.30 | 19-JUN-19:00 |
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT | 0.34 | 0.00 | 01-JAN-00:15 | 421.77 | 07-DEC-16:00 |
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT | 19.99 | 0.00 | 01-JAN-03:30 | 2003.30 | 19-JUN-19:00 |
EnergyTransfer:Zone:F3 N2 APARTMENT | 20.35 | 0.14 | 22-DEC-17:45 | 1994.19 | 19-JUN-19:00 |
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT | 0.34 | 0.00 | 01-JAN-00:15 | 425.64 | 07-DEC-16:00 |
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT | 20.02 | 0.00 | 01-JAN-02:15 | 1994.19 | 19-JUN-19:00 |
EnergyTransfer:Zone:F3 S1 APARTMENT | 29.87 | 0.15 | 22-MAR-09:45 | 2531.09 | 28-DEC-11:15 |
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT | 0.10 | 0.00 | 01-JAN-00:15 | 169.87 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT | 29.77 | 0.00 | 02-JAN-10:30 | 2531.09 | 28-DEC-11:15 |
EnergyTransfer:Zone:F3 S2 APARTMENT | 29.92 | 0.07 | 17-JAN-09:45 | 2539.76 | 28-DEC-11:15 |
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT | 0.10 | 0.00 | 01-JAN-00:15 | 171.44 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT | 29.82 | 0.00 | 02-JAN-10:30 | 2539.76 | 28-DEC-11:15 |
EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F4 SW APARTMENT | 36.57 | 0.00 | 13-OCT-00:15 | 3883.69 | 01-NOV-15:15 |
Heating:EnergyTransfer:Zone:F4 SW APARTMENT | 0.46 | 0.00 | 01-JAN-00:15 | 452.80 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT | 36.10 | 0.00 | 02-JAN-10:30 | 3883.69 | 01-NOV-15:15 |
EnergyTransfer:Zone:F4 NW APARTMENT | 27.79 | 0.01 | 07-NOV-03:15 | 3647.56 | 22-JUL-17:30 |
Heating:EnergyTransfer:Zone:F4 NW APARTMENT | 1.22 | 0.00 | 01-JAN-16:15 | 807.25 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT | 26.57 | 0.00 | 01-JAN-00:15 | 3647.56 | 22-JUL-17:30 |
EnergyTransfer:Zone:F4 SE APARTMENT | 37.32 | 0.05 | 09-JAN-01:15 | 3302.33 | 09-OCT-10:45 |
Heating:EnergyTransfer:Zone:F4 SE APARTMENT | 0.30 | 0.00 | 01-JAN-00:15 | 344.94 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT | 37.02 | 0.00 | 02-JAN-18:15 | 3302.33 | 09-OCT-10:45 |
EnergyTransfer:Zone:F4 NE APARTMENT | 28.18 | 0.01 | 21-NOV-02:00 | 2977.29 | 28-JUN-08:30 |
Heating:EnergyTransfer:Zone:F4 NE APARTMENT | 0.82 | 0.00 | 01-JAN-08:30 | 814.34 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT | 27.36 | 0.00 | 01-JAN-00:15 | 2977.29 | 28-JUN-08:30 |
EnergyTransfer:Zone:F4 N1 APARTMENT | 20.74 | 0.05 | 28-OCT-12:00 | 2015.50 | 19-JUN-19:00 |
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT | 0.33 | 0.00 | 01-JAN-00:15 | 409.64 | 07-DEC-16:00 |
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT | 20.41 | 0.00 | 01-JAN-04:15 | 2015.50 | 19-JUN-19:00 |
EnergyTransfer:Zone:F4 N2 APARTMENT | 20.77 | 0.00 | 08-JAN-12:45 | 2006.63 | 19-JUN-19:00 |
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT | 0.33 | 0.00 | 01-JAN-00:15 | 413.73 | 07-DEC-16:00 |
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT | 20.43 | 0.00 | 01-JAN-03:45 | 2006.63 | 19-JUN-19:00 |
EnergyTransfer:Zone:F4 S1 APARTMENT | 30.29 | 0.45 | 30-MAR-10:45 | 2575.58 | 28-DEC-11:15 |
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT | 0.11 | 0.00 | 01-JAN-00:15 | 176.82 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT | 30.18 | 0.00 | 02-JAN-10:30 | 2575.58 | 28-DEC-11:15 |
EnergyTransfer:Zone:F4 S2 APARTMENT | 30.32 | 0.03 | 22-NOV-12:30 | 2583.14 | 28-DEC-11:15 |
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT | 0.11 | 0.00 | 01-JAN-00:15 | 178.71 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT | 30.21 | 0.00 | 02-JAN-10:30 | 2583.14 | 28-DEC-11:15 |
EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M SW APARTMENT | 37.03 | 0.00 | 12-DEC-13:45 | 3912.03 | 01-NOV-15:15 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.48 | 0.00 | 01-JAN-00:15 | 471.05 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 36.55 | 0.00 | 02-JAN-10:30 | 3912.03 | 01-NOV-15:15 |
EnergyTransfer:Zone:M NW APARTMENT | 28.35 | 0.00 | 26-JAN-04:00 | 3690.32 | 22-JUL-17:30 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 1.24 | 0.00 | 01-JAN-16:15 | 814.71 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 27.11 | 0.00 | 01-JAN-00:15 | 3690.32 | 22-JUL-17:30 |
EnergyTransfer:Zone:M SE APARTMENT | 37.79 | 0.00 | 09-JAN-00:30 | 3337.08 | 09-OCT-10:45 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.32 | 0.00 | 01-JAN-00:15 | 366.38 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 37.47 | 0.00 | 02-JAN-18:15 | 3337.08 | 09-OCT-10:45 |
EnergyTransfer:Zone:M NE APARTMENT | 28.75 | 0.01 | 15-NOV-02:15 | 3007.56 | 28-JUN-08:30 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 0.84 | 0.00 | 01-JAN-08:30 | 823.56 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 27.91 | 0.00 | 01-JAN-00:15 | 3007.56 | 28-JUN-08:30 |
EnergyTransfer:Zone:M N1 APARTMENT | 21.37 | 0.26 | 16-DEC-14:30 | 2053.43 | 19-JUN-19:00 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.35 | 0.00 | 01-JAN-00:15 | 400.77 | 07-DEC-16:00 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 21.02 | 0.00 | 01-JAN-04:45 | 2053.43 | 19-JUN-19:00 |
EnergyTransfer:Zone:M N2 APARTMENT | 21.39 | 0.02 | 02-JAN-10:15 | 2044.79 | 19-JUN-19:00 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.34 | 0.00 | 01-JAN-00:15 | 405.01 | 07-DEC-16:00 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 21.05 | 0.00 | 01-JAN-04:15 | 2044.79 | 19-JUN-19:00 |
EnergyTransfer:Zone:M S1 APARTMENT | 30.91 | 0.74 | 28-JAN-09:15 | 2606.40 | 28-DEC-11:15 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.12 | 0.00 | 01-JAN-00:15 | 191.60 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 30.79 | 0.00 | 02-JAN-10:30 | 2606.40 | 28-DEC-11:15 |
EnergyTransfer:Zone:M S2 APARTMENT | 30.94 | 0.52 | 22-NOV-14:00 | 2613.78 | 28-DEC-11:15 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.12 | 0.00 | 01-JAN-00:15 | 193.62 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 30.82 | 0.00 | 02-JAN-10:30 | 2613.78 | 28-DEC-11:15 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F6 SW APARTMENT | 35.98 | 0.01 | 14-FEB-01:30 | 3872.98 | 01-NOV-15:15 |
Heating:EnergyTransfer:Zone:F6 SW APARTMENT | 0.54 | 0.00 | 01-JAN-00:15 | 497.78 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT | 35.44 | 0.00 | 02-JAN-10:30 | 3872.98 | 01-NOV-15:15 |
EnergyTransfer:Zone:F6 NW APARTMENT | 27.73 | 0.02 | 15-FEB-05:45 | 3653.16 | 22-JUL-17:30 |
Heating:EnergyTransfer:Zone:F6 NW APARTMENT | 1.35 | 0.00 | 01-JAN-16:30 | 872.12 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT | 26.38 | 0.00 | 01-JAN-00:15 | 3653.16 | 22-JUL-17:30 |
EnergyTransfer:Zone:F6 SE APARTMENT | 36.71 | 0.00 | 19-FEB-10:15 | 3290.28 | 09-OCT-10:45 |
Heating:EnergyTransfer:Zone:F6 SE APARTMENT | 0.36 | 0.00 | 01-JAN-00:15 | 393.23 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT | 36.35 | 0.00 | 02-JAN-10:30 | 3290.28 | 09-OCT-10:45 |
EnergyTransfer:Zone:F6 NE APARTMENT | 28.09 | 0.01 | 10-NOV-05:30 | 2965.41 | 28-JUN-08:30 |
Heating:EnergyTransfer:Zone:F6 NE APARTMENT | 0.92 | 0.00 | 01-JAN-08:30 | 879.76 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT | 27.17 | 0.00 | 01-JAN-00:15 | 2965.41 | 28-JUN-08:30 |
EnergyTransfer:Zone:F6 N1 APARTMENT | 20.73 | 0.55 | 07-DEC-13:15 | 2019.55 | 19-JUN-19:00 |
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT | 0.38 | 0.00 | 01-JAN-00:15 | 492.94 | 03-FEB-13:45 |
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT | 20.35 | 0.00 | 01-JAN-01:45 | 2019.55 | 19-JUN-19:00 |
EnergyTransfer:Zone:F6 N2 APARTMENT | 20.75 | 0.01 | 03-MAR-14:45 | 2011.17 | 19-JUN-19:00 |
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT | 0.38 | 0.00 | 01-JAN-00:15 | 498.86 | 03-FEB-13:45 |
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT | 20.37 | 0.00 | 01-JAN-01:15 | 2011.17 | 19-JUN-19:00 |
EnergyTransfer:Zone:F6 S1 APARTMENT | 29.84 | 0.12 | 29-MAR-17:30 | 2556.80 | 28-DEC-11:15 |
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT | 0.13 | 0.00 | 01-JAN-00:15 | 209.90 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT | 29.71 | 0.00 | 02-JAN-10:30 | 2556.80 | 28-DEC-11:15 |
EnergyTransfer:Zone:F6 S2 APARTMENT | 29.87 | 0.04 | 16-NOV-15:45 | 2563.96 | 28-DEC-11:15 |
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT | 0.13 | 0.00 | 01-JAN-00:15 | 212.44 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT | 29.74 | 0.00 | 02-JAN-10:30 | 2563.96 | 28-DEC-11:15 |
EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F7 SW APARTMENT | 35.43 | 0.01 | 18-JAN-01:00 | 3856.83 | 01-NOV-15:15 |
Heating:EnergyTransfer:Zone:F7 SW APARTMENT | 0.58 | 0.00 | 01-JAN-00:15 | 510.78 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT | 34.84 | 0.00 | 02-JAN-10:30 | 3856.83 | 01-NOV-15:15 |
EnergyTransfer:Zone:F7 NW APARTMENT | 27.53 | 0.01 | 22-NOV-23:15 | 3638.20 | 22-JUL-17:45 |
Heating:EnergyTransfer:Zone:F7 NW APARTMENT | 1.46 | 0.00 | 01-JAN-16:30 | 916.77 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT | 26.08 | 0.00 | 01-JAN-00:15 | 3638.20 | 22-JUL-17:45 |
EnergyTransfer:Zone:F7 SE APARTMENT | 36.15 | 0.00 | 03-FEB-23:30 | 3266.59 | 09-OCT-10:45 |
Heating:EnergyTransfer:Zone:F7 SE APARTMENT | 0.39 | 0.00 | 01-JAN-00:15 | 410.38 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT | 35.76 | 0.00 | 02-JAN-10:30 | 3266.59 | 09-OCT-10:45 |
EnergyTransfer:Zone:F7 NE APARTMENT | 27.86 | 0.00 | 02-DEC-23:00 | 2952.89 | 28-JUN-08:30 |
Heating:EnergyTransfer:Zone:F7 NE APARTMENT | 1.00 | 0.00 | 01-JAN-08:30 | 923.52 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT | 26.86 | 0.00 | 01-JAN-00:15 | 2952.89 | 28-JUN-08:30 |
EnergyTransfer:Zone:F7 N1 APARTMENT | 20.49 | 0.06 | 23-OCT-12:45 | 2013.43 | 22-JUL-17:30 |
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT | 0.42 | 0.00 | 01-JAN-00:15 | 661.75 | 03-FEB-16:00 |
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT | 20.07 | 0.00 | 01-JAN-01:00 | 2013.43 | 22-JUL-17:30 |
EnergyTransfer:Zone:F7 N2 APARTMENT | 20.52 | 0.18 | 01-JAN-07:00 | 2005.38 | 22-JUL-17:30 |
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT | 0.42 | 0.00 | 01-JAN-00:15 | 664.61 | 03-FEB-16:00 |
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT | 20.10 | 0.00 | 01-JAN-01:00 | 2005.38 | 22-JUL-17:30 |
EnergyTransfer:Zone:F7 S1 APARTMENT | 29.31 | 0.52 | 22-MAR-10:15 | 2525.95 | 28-DEC-11:15 |
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT | 0.14 | 0.00 | 01-JAN-00:15 | 238.91 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT | 29.17 | 0.00 | 02-JAN-10:30 | 2525.95 | 28-DEC-11:15 |
EnergyTransfer:Zone:F7 S2 APARTMENT | 29.34 | 0.16 | 15-NOV-18:30 | 2532.92 | 28-DEC-11:15 |
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT | 0.14 | 0.00 | 01-JAN-00:15 | 233.49 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT | 29.20 | 0.00 | 02-JAN-10:30 | 2532.92 | 28-DEC-11:15 |
EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F8 SW APARTMENT | 35.10 | 0.02 | 05-JAN-04:00 | 3855.78 | 01-NOV-15:15 |
Heating:EnergyTransfer:Zone:F8 SW APARTMENT | 0.63 | 0.00 | 01-JAN-00:15 | 517.59 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT | 34.47 | 0.00 | 01-JAN-05:15 | 3855.78 | 01-NOV-15:15 |
EnergyTransfer:Zone:F8 NW APARTMENT | 27.56 | 0.05 | 09-FEB-03:00 | 3640.56 | 22-JUL-17:45 |
Heating:EnergyTransfer:Zone:F8 NW APARTMENT | 1.57 | 0.00 | 01-JAN-22:45 | 962.23 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT | 25.99 | 0.00 | 01-JAN-00:15 | 3640.56 | 22-JUL-17:45 |
EnergyTransfer:Zone:F8 SE APARTMENT | 35.81 | 0.00 | 22-FEB-23:45 | 3270.61 | 05-OCT-09:15 |
Heating:EnergyTransfer:Zone:F8 SE APARTMENT | 0.43 | 0.00 | 01-JAN-00:15 | 506.20 | 10-FEB-12:30 |
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT | 35.38 | 0.00 | 01-JAN-04:45 | 3270.61 | 05-OCT-09:15 |
EnergyTransfer:Zone:F8 NE APARTMENT | 27.85 | 0.00 | 22-OCT-22:15 | 2956.77 | 28-JUN-08:30 |
Heating:EnergyTransfer:Zone:F8 NE APARTMENT | 1.09 | 0.00 | 01-JAN-08:45 | 992.38 | 03-FEB-16:00 |
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT | 26.76 | 0.00 | 01-JAN-00:15 | 2956.77 | 28-JUN-08:30 |
EnergyTransfer:Zone:F8 N1 APARTMENT | 20.46 | 0.02 | 20-NOV-02:45 | 2028.79 | 22-JUL-17:45 |
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT | 0.47 | 0.00 | 01-JAN-00:15 | 836.29 | 03-FEB-16:00 |
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT | 20.00 | 0.00 | 01-JAN-00:45 | 2028.79 | 22-JUL-17:45 |
EnergyTransfer:Zone:F8 N2 APARTMENT | 20.49 | 0.01 | 10-FEB-03:30 | 2021.02 | 22-JUL-17:45 |
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT | 0.46 | 0.00 | 01-JAN-00:15 | 838.61 | 03-FEB-16:00 |
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT | 20.02 | 0.00 | 01-JAN-00:30 | 2021.02 | 22-JUL-17:45 |
EnergyTransfer:Zone:F8 S1 APARTMENT | 29.00 | 0.16 | 14-FEB-16:30 | 2491.13 | 28-DEC-11:15 |
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT | 0.16 | 0.00 | 01-JAN-00:15 | 380.11 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT | 28.83 | 0.00 | 02-JAN-10:30 | 2491.13 | 28-DEC-11:15 |
EnergyTransfer:Zone:F8 S2 APARTMENT | 29.03 | 0.09 | 25-NOV-14:00 | 2497.94 | 28-DEC-11:15 |
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT | 0.16 | 0.00 | 01-JAN-00:15 | 411.30 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT | 28.86 | 0.00 | 02-JAN-10:30 | 2497.94 | 28-DEC-11:15 |
EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F9 SW APARTMENT | 35.28 | 0.01 | 07-DEC-01:30 | 3936.46 | 01-NOV-15:15 |
Heating:EnergyTransfer:Zone:F9 SW APARTMENT | 0.77 | 0.00 | 01-JAN-00:15 | 671.06 | 08-MAR-09:45 |
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT | 34.51 | 0.00 | 01-JAN-04:15 | 3936.46 | 01-NOV-15:15 |
EnergyTransfer:Zone:F9 NW APARTMENT | 28.34 | 0.01 | 26-OCT-00:45 | 3742.59 | 22-JUL-17:45 |
Heating:EnergyTransfer:Zone:F9 NW APARTMENT | 1.85 | 0.00 | 01-JAN-22:45 | 1053.54 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT | 26.49 | 0.00 | 01-JAN-00:15 | 3742.59 | 22-JUL-17:45 |
EnergyTransfer:Zone:F9 SE APARTMENT | 35.92 | 0.01 | 23-FEB-00:45 | 3320.78 | 28-SEP-10:15 |
Heating:EnergyTransfer:Zone:F9 SE APARTMENT | 0.52 | 0.00 | 01-JAN-00:15 | 668.19 | 10-FEB-12:30 |
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT | 35.41 | 0.00 | 01-JAN-03:30 | 3320.78 | 28-SEP-10:15 |
EnergyTransfer:Zone:F9 NE APARTMENT | 28.46 | 0.01 | 09-JAN-21:15 | 3009.60 | 28-JUN-08:30 |
Heating:EnergyTransfer:Zone:F9 NE APARTMENT | 1.27 | 0.00 | 01-JAN-09:00 | 1180.60 | 03-FEB-16:00 |
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT | 27.19 | 0.00 | 01-JAN-00:15 | 3009.60 | 28-JUN-08:30 |
EnergyTransfer:Zone:F9 N1 APARTMENT | 20.98 | 0.08 | 13-NOV-24:00 | 2128.53 | 22-JUL-17:45 |
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT | 0.58 | 0.00 | 01-JAN-00:15 | 1068.24 | 03-FEB-16:00 |
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT | 20.39 | 0.00 | 01-JAN-00:30 | 2128.53 | 22-JUL-17:45 |
EnergyTransfer:Zone:F9 N2 APARTMENT | 21.00 | 0.06 | 06-FEB-12:30 | 2120.80 | 22-JUL-17:45 |
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT | 0.58 | 0.00 | 01-JAN-10:30 | 1067.33 | 03-FEB-16:00 |
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT | 20.42 | 0.00 | 01-JAN-00:15 | 2120.80 | 22-JUL-17:45 |
EnergyTransfer:Zone:F9 S1 APARTMENT | 29.06 | 0.08 | 09-FEB-12:30 | 2535.40 | 02-NOV-13:30 |
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT | 0.20 | 0.00 | 01-JAN-00:15 | 428.56 | 10-FEB-12:30 |
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT | 28.86 | 0.00 | 02-JAN-10:30 | 2535.40 | 02-NOV-13:30 |
EnergyTransfer:Zone:F9 S2 APARTMENT | 29.09 | 0.03 | 11-FEB-02:00 | 2541.22 | 02-NOV-13:30 |
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT | 0.20 | 0.00 | 01-JAN-00:15 | 429.65 | 10-FEB-12:30 |
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT | 28.89 | 0.00 | 02-JAN-10:30 | 2541.22 | 02-NOV-13:30 |
EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:T SW APARTMENT | 38.56 | 0.20 | 03-MAY-02:45 | 4595.63 | 05-OCT-15:15 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 2.30 | 0.00 | 01-JAN-09:00 | 1435.63 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 36.26 | 0.00 | 01-JAN-00:15 | 4595.63 | 05-OCT-15:15 |
EnergyTransfer:Zone:T NW APARTMENT | 32.21 | 0.11 | 13-DEC-18:15 | 4403.31 | 22-JUL-17:30 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 3.71 | 0.00 | 01-JAN-15:30 | 1734.03 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 28.50 | 0.00 | 01-JAN-00:15 | 4403.31 | 22-JUL-17:30 |
EnergyTransfer:Zone:T SE APARTMENT | 38.61 | 0.14 | 18-MAR-00:30 | 4010.46 | 28-SEP-10:45 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 1.83 | 0.00 | 01-JAN-08:30 | 1450.96 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 36.78 | 0.00 | 01-JAN-00:15 | 4010.46 | 28-SEP-10:45 |
EnergyTransfer:Zone:T NE APARTMENT | 31.68 | 0.31 | 07-JAN-14:30 | 3526.02 | 22-JUL-18:00 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 2.92 | 0.00 | 02-JAN-08:30 | 1750.65 | 07-DEC-05:00 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 28.76 | 0.00 | 01-JAN-00:15 | 3526.02 | 22-JUL-18:00 |
EnergyTransfer:Zone:T N1 APARTMENT | 22.89 | 0.01 | 26-NOV-09:30 | 2605.11 | 22-JUL-17:30 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 1.19 | 0.00 | 01-JAN-18:00 | 1373.03 | 22-NOV-12:00 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 21.70 | 0.00 | 01-JAN-00:15 | 2605.11 | 22-JUL-17:30 |
EnergyTransfer:Zone:T N2 APARTMENT | 22.94 | 0.02 | 13-NOV-05:30 | 2637.39 | 11-JUL-17:30 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 1.19 | 0.00 | 01-JAN-11:45 | 1347.82 | 22-NOV-12:00 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 21.75 | 0.00 | 01-JAN-00:15 | 2637.39 | 11-JUL-17:30 |
EnergyTransfer:Zone:T S1 APARTMENT | 30.33 | 0.01 | 22-DEC-04:30 | 3178.49 | 02-NOV-13:45 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 0.58 | 0.00 | 01-JAN-00:15 | 1042.66 | 10-FEB-12:30 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 29.75 | 0.00 | 01-JAN-01:00 | 3178.49 | 02-NOV-13:45 |
EnergyTransfer:Zone:T S2 APARTMENT | 30.38 | 0.01 | 10-NOV-00:30 | 3179.01 | 02-NOV-13:45 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 0.58 | 0.00 | 01-JAN-00:15 | 1043.82 | 10-FEB-12:30 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 29.79 | 0.00 | 01-JAN-01:00 | 3179.01 | 02-NOV-13:45 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Plant | 683.38 | 344.92 | 25-JUL-01:15 | 85436.27 | 07-DEC-06:15 |
WaterSystems:EnergyTransfer | 681.08 | 344.92 | 25-JUL-01:15 | 48962.98 | 20-JAN-07:15 |
sub cat:WaterSystems:EnergyTransfer | 681.08 | 344.92 | 25-JUL-01:15 | 48962.98 | 20-JAN-07:15 |
EnergyTransfer:HVAC | 2848.56 | 0.00 | 02-JAN-18:45 | 276721.03 | 13-JUL-18:45 |
CoolingCoils:EnergyTransfer | 2832.45 | 0.00 | 01-JAN-00:15 | 276721.03 | 13-JUL-18:45 |
HeatingCoils:EnergyTransfer | 16.12 | 0.00 | 01-JAN-12:00 | 59147.91 | 07-DEC-05:00 |
PlantLoopHeatingDemand:HVAC | 12.42 | 0.00 | 01-JAN-12:00 | 45141.81 | 07-DEC-05:00 |
HeatingCoils:PlantLoopHeatingDemand | 12.42 | 0.00 | 01-JAN-12:00 | 45141.81 | 07-DEC-05:00 |
Boilers:EnergyTransfer | 2.30 | 0.00 | 01-JAN-00:15 | 43216.57 | 07-DEC-05:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:11
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 0.999 | -23.654 | 0.000 | 0.000 | 3.646 | 2.413 | 12.213 | 28.355 | 0.000 | 0.774 | 0.001 | 0.000 | -7.554 | 0.000 | -4.468 | -12.723 |
G NW APARTMENT | 1.979 | -17.784 | 0.000 | 0.000 | 3.693 | 2.413 | 12.213 | 16.925 | 0.000 | 0.766 | 0.000 | 0.000 | -7.587 | 0.000 | -3.695 | -8.922 |
OFFICE | 0.570 | -30.830 | 0.000 | 0.000 | 0.504 | 21.954 | 7.547 | 28.718 | 0.000 | 0.624 | 0.000 | 0.000 | -7.344 | 0.000 | -0.839 | -20.903 |
G NE APARTMENT | 1.490 | -18.028 | 0.000 | 0.000 | 3.705 | 2.413 | 12.213 | 17.164 | 0.000 | 0.767 | 0.000 | 0.000 | -7.036 | 0.000 | -3.685 | -9.003 |
G N1 APARTMENT | 0.716 | -12.476 | 0.000 | 0.000 | 3.709 | 2.413 | 12.213 | 6.660 | 0.000 | 0.521 | 0.000 | 0.000 | -4.555 | 0.000 | -3.012 | -6.187 |
G N2 APARTMENT | 0.710 | -12.497 | 0.000 | 0.000 | 3.709 | 2.413 | 12.213 | 6.657 | 0.000 | 0.520 | 0.000 | 0.000 | -4.552 | 0.000 | -3.012 | -6.162 |
G S1 APARTMENT | 0.167 | -18.282 | 0.000 | 0.000 | 3.638 | 2.413 | 12.213 | 18.258 | 0.000 | 0.523 | 0.002 | 0.000 | -4.553 | 0.000 | -4.004 | -10.374 |
G S2 APARTMENT | 0.176 | -18.535 | 0.000 | 0.000 | 3.636 | 2.413 | 12.213 | 18.248 | 0.000 | 0.524 | 0.001 | 0.000 | -4.560 | 0.000 | -4.027 | -10.088 |
F2 SW APARTMENT | 0.535 | -34.352 | 0.000 | 0.000 | 3.565 | 2.413 | 12.213 | 27.334 | 0.000 | 1.069 | 1.073 | 0.000 | -8.332 | 0.000 | -5.518 | -0.001 |
F2 NW APARTMENT | 1.454 | -25.141 | 0.000 | 0.000 | 3.621 | 2.413 | 12.213 | 16.201 | 0.000 | 1.057 | 1.340 | 0.000 | -8.344 | 0.000 | -4.816 | -0.000 |
F2 SE APARTMENT | 0.352 | -36.376 | 0.000 | 0.000 | 3.567 | 2.413 | 12.213 | 27.856 | 0.000 | 1.071 | 2.538 | 0.000 | -8.078 | 0.000 | -5.555 | -0.000 |
F2 NE APARTMENT | 0.950 | -25.786 | 0.000 | 0.000 | 3.635 | 2.413 | 12.213 | 16.455 | 0.000 | 1.059 | 1.552 | 0.000 | -7.712 | 0.000 | -4.778 | -0.000 |
F2 N1 APARTMENT | 0.412 | -18.650 | 0.000 | 0.000 | 3.627 | 2.413 | 12.213 | 6.322 | 0.000 | 0.703 | 2.068 | 0.000 | -5.076 | 0.000 | -4.031 | -0.000 |
F2 N2 APARTMENT | 0.407 | -18.678 | 0.000 | 0.000 | 3.628 | 2.413 | 12.213 | 6.320 | 0.000 | 0.703 | 2.096 | 0.000 | -5.072 | 0.000 | -4.030 | -0.000 |
F2 S1 APARTMENT | 0.114 | -27.726 | 0.000 | 0.000 | 3.551 | 2.413 | 12.213 | 17.628 | 0.000 | 0.704 | 1.110 | 0.000 | -5.031 | 0.000 | -4.976 | -0.000 |
F2 S2 APARTMENT | 0.116 | -27.855 | 0.000 | 0.000 | 3.551 | 2.413 | 12.213 | 17.626 | 0.000 | 0.705 | 1.245 | 0.000 | -5.033 | 0.000 | -4.980 | -0.000 |
F3 SW APARTMENT | 0.452 | -35.912 | 0.000 | 0.000 | 3.554 | 2.413 | 12.213 | 26.865 | 0.000 | 1.244 | 3.684 | 0.000 | -8.514 | 0.000 | -5.999 | -0.000 |
F3 NW APARTMENT | 1.238 | -26.281 | 0.000 | 0.000 | 3.604 | 2.413 | 12.213 | 15.901 | 0.000 | 1.231 | 3.578 | 0.000 | -8.570 | 0.000 | -5.327 | -0.000 |
F3 SE APARTMENT | 0.293 | -36.941 | 0.000 | 0.000 | 3.559 | 2.413 | 12.213 | 27.445 | 0.000 | 1.245 | 3.993 | 0.000 | -8.216 | 0.000 | -6.003 | -0.000 |
F3 NE APARTMENT | 0.826 | -27.036 | 0.000 | 0.000 | 3.617 | 2.413 | 12.213 | 16.178 | 0.000 | 1.232 | 3.765 | 0.000 | -7.924 | 0.000 | -5.285 | -0.000 |
F3 N1 APARTMENT | 0.339 | -19.994 | 0.000 | 0.000 | 3.603 | 2.413 | 12.213 | 6.218 | 0.000 | 0.812 | 4.145 | 0.000 | -5.247 | 0.000 | -4.502 | -0.000 |
F3 N2 APARTMENT | 0.335 | -20.019 | 0.000 | 0.000 | 3.604 | 2.413 | 12.213 | 6.217 | 0.000 | 0.812 | 4.168 | 0.000 | -5.242 | 0.000 | -4.500 | -0.000 |
F3 S1 APARTMENT | 0.098 | -29.767 | 0.000 | 0.000 | 3.538 | 2.413 | 12.213 | 17.349 | 0.000 | 0.813 | 3.888 | 0.000 | -5.152 | 0.000 | -5.392 | -0.000 |
F3 S2 APARTMENT | 0.099 | -29.816 | 0.000 | 0.000 | 3.538 | 2.413 | 12.213 | 17.348 | 0.000 | 0.813 | 3.937 | 0.000 | -5.152 | 0.000 | -5.392 | -0.000 |
F4 SW APARTMENT | 0.462 | -36.103 | 0.000 | 0.000 | 3.553 | 2.413 | 12.213 | 26.549 | 0.000 | 1.375 | 4.463 | 0.000 | -8.591 | 0.000 | -6.335 | -0.000 |
F4 NW APARTMENT | 1.220 | -26.570 | 0.000 | 0.000 | 3.601 | 2.413 | 12.213 | 15.714 | 0.000 | 1.360 | 4.361 | 0.000 | -8.665 | 0.000 | -5.647 | -0.000 |
F4 SE APARTMENT | 0.303 | -37.016 | 0.000 | 0.000 | 3.559 | 2.413 | 12.213 | 27.153 | 0.000 | 1.376 | 4.617 | 0.000 | -8.283 | 0.000 | -6.335 | -0.000 |
F4 NE APARTMENT | 0.820 | -27.356 | 0.000 | 0.000 | 3.614 | 2.413 | 12.213 | 16.007 | 0.000 | 1.362 | 4.545 | 0.000 | -8.013 | 0.000 | -5.604 | -0.000 |
F4 N1 APARTMENT | 0.334 | -20.410 | 0.000 | 0.000 | 3.596 | 2.413 | 12.213 | 6.163 | 0.000 | 0.894 | 4.897 | 0.000 | -5.322 | 0.000 | -4.777 | -0.000 |
F4 N2 APARTMENT | 0.331 | -20.434 | 0.000 | 0.000 | 3.597 | 2.413 | 12.213 | 6.162 | 0.000 | 0.894 | 4.919 | 0.000 | -5.318 | 0.000 | -4.775 | -0.000 |
F4 S1 APARTMENT | 0.105 | -30.180 | 0.000 | 0.000 | 3.536 | 2.413 | 12.213 | 17.165 | 0.000 | 0.896 | 4.719 | 0.000 | -5.204 | 0.000 | -5.662 | -0.000 |
F4 S2 APARTMENT | 0.106 | -30.212 | 0.000 | 0.000 | 3.536 | 2.413 | 12.213 | 17.164 | 0.000 | 0.896 | 4.750 | 0.000 | -5.203 | 0.000 | -5.663 | -0.000 |
M SW APARTMENT | 0.482 | -36.551 | 0.000 | 0.000 | 3.552 | 2.413 | 12.213 | 26.287 | 0.000 | 1.481 | 5.408 | 0.000 | -8.658 | 0.000 | -6.628 | -0.001 |
M NW APARTMENT | 1.239 | -27.110 | 0.000 | 0.000 | 3.599 | 2.413 | 12.213 | 15.559 | 0.000 | 1.464 | 5.283 | 0.000 | -8.740 | 0.000 | -5.919 | -0.000 |
M SE APARTMENT | 0.319 | -37.466 | 0.000 | 0.000 | 3.558 | 2.413 | 12.213 | 26.907 | 0.000 | 1.482 | 5.549 | 0.000 | -8.348 | 0.000 | -6.627 | -0.000 |
M NE APARTMENT | 0.837 | -27.913 | 0.000 | 0.000 | 3.611 | 2.413 | 12.213 | 15.863 | 0.000 | 1.466 | 5.469 | 0.000 | -8.084 | 0.000 | -5.876 | -0.000 |
M N1 APARTMENT | 0.347 | -21.025 | 0.000 | 0.000 | 3.592 | 2.413 | 12.213 | 6.116 | 0.000 | 0.959 | 5.771 | 0.000 | -5.379 | 0.000 | -5.006 | 0.000 |
M N2 APARTMENT | 0.343 | -21.048 | 0.000 | 0.000 | 3.592 | 2.413 | 12.213 | 6.115 | 0.000 | 0.959 | 5.793 | 0.000 | -5.375 | 0.000 | -5.004 | 0.000 |
M S1 APARTMENT | 0.116 | -30.791 | 0.000 | 0.000 | 3.535 | 2.413 | 12.213 | 17.013 | 0.000 | 0.963 | 5.686 | 0.000 | -5.249 | 0.000 | -5.898 | -0.000 |
M S2 APARTMENT | 0.117 | -30.819 | 0.000 | 0.000 | 3.535 | 2.413 | 12.213 | 17.012 | 0.000 | 0.963 | 5.713 | 0.000 | -5.248 | 0.000 | -5.898 | -0.000 |
F6 SW APARTMENT | 0.535 | -35.440 | 0.000 | 0.000 | 3.558 | 2.413 | 12.213 | 26.108 | 0.000 | 1.594 | 4.516 | 0.000 | -8.654 | 0.000 | -6.842 | -0.000 |
F6 NW APARTMENT | 1.351 | -26.380 | 0.000 | 0.000 | 3.607 | 2.413 | 12.213 | 15.474 | 0.000 | 1.574 | 4.521 | 0.000 | -8.713 | 0.000 | -6.061 | -0.000 |
F6 SE APARTMENT | 0.357 | -36.350 | 0.000 | 0.000 | 3.564 | 2.413 | 12.213 | 26.739 | 0.000 | 1.595 | 4.655 | 0.000 | -8.343 | 0.000 | -6.843 | -0.000 |
F6 NE APARTMENT | 0.917 | -27.172 | 0.000 | 0.000 | 3.621 | 2.413 | 12.213 | 15.793 | 0.000 | 1.576 | 4.712 | 0.000 | -8.057 | 0.000 | -6.015 | -0.000 |
F6 N1 APARTMENT | 0.380 | -20.349 | 0.000 | 0.000 | 3.601 | 2.413 | 12.213 | 6.105 | 0.000 | 1.036 | 5.061 | 0.000 | -5.363 | 0.000 | -5.095 | -0.000 |
F6 N2 APARTMENT | 0.377 | -20.375 | 0.000 | 0.000 | 3.601 | 2.413 | 12.213 | 6.103 | 0.000 | 1.036 | 5.083 | 0.000 | -5.359 | 0.000 | -5.093 | -0.000 |
F6 S1 APARTMENT | 0.129 | -29.715 | 0.000 | 0.000 | 3.539 | 2.413 | 12.213 | 16.909 | 0.000 | 1.041 | 4.785 | 0.000 | -5.252 | 0.000 | -6.063 | -0.001 |
F6 S2 APARTMENT | 0.130 | -29.743 | 0.000 | 0.000 | 3.540 | 2.413 | 12.213 | 16.908 | 0.000 | 1.041 | 4.812 | 0.000 | -5.251 | 0.000 | -6.063 | -0.000 |
F7 SW APARTMENT | 0.582 | -34.844 | 0.000 | 0.000 | 3.562 | 2.413 | 12.213 | 25.940 | 0.000 | 1.676 | 4.160 | 0.000 | -8.663 | 0.000 | -7.039 | -0.000 |
F7 NW APARTMENT | 1.456 | -26.078 | 0.000 | 0.000 | 3.614 | 2.413 | 12.213 | 15.391 | 0.000 | 1.654 | 4.235 | 0.000 | -8.700 | 0.000 | -6.197 | -0.000 |
F7 SE APARTMENT | 0.391 | -35.755 | 0.000 | 0.000 | 3.569 | 2.413 | 12.213 | 26.581 | 0.000 | 1.677 | 4.302 | 0.000 | -8.350 | 0.000 | -7.041 | -0.000 |
F7 NE APARTMENT | 0.999 | -26.861 | 0.000 | 0.000 | 3.628 | 2.413 | 12.213 | 15.721 | 0.000 | 1.655 | 4.427 | 0.000 | -8.045 | 0.000 | -6.150 | -0.000 |
F7 N1 APARTMENT | 0.418 | -20.074 | 0.000 | 0.000 | 3.608 | 2.413 | 12.213 | 6.089 | 0.000 | 1.087 | 4.788 | 0.000 | -5.355 | 0.000 | -5.186 | -0.000 |
F7 N2 APARTMENT | 0.416 | -20.102 | 0.000 | 0.000 | 3.608 | 2.413 | 12.213 | 6.087 | 0.000 | 1.087 | 4.812 | 0.000 | -5.351 | 0.000 | -5.183 | -0.000 |
F7 S1 APARTMENT | 0.144 | -29.167 | 0.000 | 0.000 | 3.543 | 2.413 | 12.213 | 16.812 | 0.000 | 1.094 | 4.425 | 0.000 | -5.262 | 0.000 | -6.214 | -0.000 |
F7 S2 APARTMENT | 0.145 | -29.196 | 0.000 | 0.000 | 3.543 | 2.413 | 12.213 | 16.811 | 0.000 | 1.094 | 4.452 | 0.000 | -5.261 | 0.000 | -6.214 | -0.000 |
F8 SW APARTMENT | 0.634 | -34.467 | 0.000 | 0.000 | 3.566 | 2.413 | 12.213 | 25.788 | 0.000 | 1.745 | 4.007 | 0.000 | -8.673 | 0.000 | -7.226 | -0.000 |
F8 NW APARTMENT | 1.575 | -25.987 | 0.000 | 0.000 | 3.621 | 2.413 | 12.213 | 15.314 | 0.000 | 1.722 | 4.151 | 0.000 | -8.693 | 0.000 | -6.328 | -0.000 |
F8 SE APARTMENT | 0.430 | -35.382 | 0.000 | 0.000 | 3.573 | 2.413 | 12.213 | 26.436 | 0.000 | 1.746 | 4.157 | 0.000 | -8.359 | 0.000 | -7.227 | -0.000 |
F8 NE APARTMENT | 1.091 | -26.757 | 0.000 | 0.000 | 3.634 | 2.413 | 12.213 | 15.651 | 0.000 | 1.723 | 4.350 | 0.000 | -8.038 | 0.000 | -6.281 | -0.000 |
F8 N1 APARTMENT | 0.466 | -19.996 | 0.000 | 0.000 | 3.614 | 2.413 | 12.213 | 6.072 | 0.000 | 1.129 | 4.713 | 0.000 | -5.349 | 0.000 | -5.274 | -0.000 |
F8 N2 APARTMENT | 0.464 | -20.024 | 0.000 | 0.000 | 3.615 | 2.413 | 12.213 | 6.070 | 0.000 | 1.129 | 4.737 | 0.000 | -5.345 | 0.000 | -5.272 | -0.000 |
F8 S1 APARTMENT | 0.162 | -28.834 | 0.000 | 0.000 | 3.546 | 2.413 | 12.213 | 16.724 | 0.000 | 1.139 | 4.267 | 0.000 | -5.272 | 0.000 | -6.358 | -0.000 |
F8 S2 APARTMENT | 0.163 | -28.863 | 0.000 | 0.000 | 3.546 | 2.413 | 12.213 | 16.723 | 0.000 | 1.139 | 4.294 | 0.000 | -5.270 | 0.000 | -6.358 | -0.000 |
F9 SW APARTMENT | 0.772 | -34.510 | 0.000 | 0.000 | 3.572 | 2.413 | 12.213 | 25.655 | 0.000 | 1.809 | 4.123 | 0.000 | -8.665 | 0.000 | -7.381 | -0.000 |
F9 NW APARTMENT | 1.853 | -26.487 | 0.000 | 0.000 | 3.628 | 2.413 | 12.213 | 15.241 | 0.000 | 1.783 | 4.453 | 0.000 | -8.675 | 0.000 | -6.422 | -0.000 |
F9 SE APARTMENT | 0.518 | -35.406 | 0.000 | 0.000 | 3.580 | 2.413 | 12.213 | 26.307 | 0.000 | 1.809 | 4.298 | 0.000 | -8.348 | 0.000 | -7.383 | -0.000 |
F9 NE APARTMENT | 1.269 | -27.188 | 0.000 | 0.000 | 3.641 | 2.413 | 12.213 | 15.587 | 0.000 | 1.784 | 4.684 | 0.000 | -8.024 | 0.000 | -6.379 | -0.000 |
F9 N1 APARTMENT | 0.581 | -20.394 | 0.000 | 0.000 | 3.622 | 2.413 | 12.213 | 6.054 | 0.000 | 1.168 | 5.004 | 0.000 | -5.332 | 0.000 | -5.327 | -0.000 |
F9 N2 APARTMENT | 0.577 | -20.421 | 0.000 | 0.000 | 3.623 | 2.413 | 12.213 | 6.052 | 0.000 | 1.168 | 5.029 | 0.000 | -5.328 | 0.000 | -5.326 | -0.000 |
F9 S1 APARTMENT | 0.202 | -28.855 | 0.000 | 0.000 | 3.553 | 2.413 | 12.213 | 16.650 | 0.000 | 1.182 | 4.377 | 0.000 | -5.269 | 0.000 | -6.466 | -0.000 |
F9 S2 APARTMENT | 0.203 | -28.887 | 0.000 | 0.000 | 3.553 | 2.413 | 12.213 | 16.649 | 0.000 | 1.182 | 4.408 | 0.000 | -5.267 | 0.000 | -6.467 | -0.000 |
T SW APARTMENT | 2.298 | -36.264 | 0.000 | 0.000 | 3.622 | 2.413 | 12.213 | 25.235 | 0.000 | 1.865 | 4.198 | 0.000 | -8.211 | 0.000 | -7.369 | -0.000 |
T NW APARTMENT | 3.707 | -28.498 | 0.000 | 0.000 | 3.658 | 2.413 | 12.213 | 14.870 | 0.000 | 1.839 | 4.632 | 0.000 | -8.299 | 0.000 | -6.536 | -0.000 |
T SE APARTMENT | 1.825 | -36.780 | 0.000 | 0.000 | 3.631 | 2.413 | 12.213 | 25.911 | 0.000 | 1.867 | 4.230 | 0.000 | -7.917 | 0.000 | -7.393 | -0.000 |
T NE APARTMENT | 2.917 | -28.759 | 0.000 | 0.000 | 3.672 | 2.413 | 12.213 | 15.275 | 0.000 | 1.840 | 4.667 | 0.000 | -7.708 | 0.000 | -6.531 | -0.000 |
T N1 APARTMENT | 1.192 | -21.696 | 0.000 | 0.000 | 3.657 | 2.413 | 12.213 | 5.920 | 0.000 | 1.202 | 5.574 | 0.000 | -5.084 | 0.000 | -5.391 | -0.000 |
T N2 APARTMENT | 1.188 | -21.751 | 0.000 | 0.000 | 3.658 | 2.413 | 12.213 | 5.918 | 0.000 | 1.203 | 5.630 | 0.000 | -5.078 | 0.000 | -5.393 | -0.000 |
T S1 APARTMENT | 0.581 | -29.752 | 0.000 | 0.000 | 3.603 | 2.413 | 12.213 | 16.437 | 0.000 | 1.223 | 4.756 | 0.000 | -5.031 | 0.000 | -6.443 | -0.000 |
T S2 APARTMENT | 0.584 | -29.792 | 0.000 | 0.000 | 3.603 | 2.413 | 12.213 | 16.434 | 0.000 | 1.224 | 4.794 | 0.000 | -5.028 | 0.000 | -6.445 | -0.000 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18.529 | 0.000 | 6.578 | 0.000 | 10.904 | 0.001 | 0.000 | -1.778 | 0.000 | -18.342 | -15.891 |
F2 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18.529 | 0.000 | 3.071 | 0.000 | 0.101 | 0.000 | 0.000 | -1.110 | 0.000 | -0.255 | -20.336 |
F3 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18.529 | 0.000 | 2.989 | 0.000 | 0.118 | 0.000 | 0.000 | -1.156 | 0.000 | -0.316 | -20.165 |
F4 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18.529 | 0.000 | 2.934 | 0.000 | 0.129 | 0.000 | 0.000 | -1.180 | 0.000 | -0.360 | -20.051 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 37.059 | 0.000 | 2.847 | 0.000 | 0.125 | 0.000 | 0.000 | -1.241 | 0.000 | -0.422 | -38.368 |
F6 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18.529 | 0.000 | 2.878 | 0.000 | 0.149 | 0.000 | 0.000 | -1.190 | 0.000 | -0.418 | -19.947 |
F7 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18.529 | 0.000 | 2.868 | 0.000 | 0.159 | 0.000 | 0.000 | -1.181 | 0.000 | -0.436 | -19.938 |
F8 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18.529 | 0.000 | 2.850 | 0.000 | 0.166 | 0.000 | 0.000 | -1.180 | 0.000 | -0.455 | -19.910 |
F9 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18.529 | 0.000 | 2.831 | 0.000 | 0.169 | 0.000 | 0.000 | -1.183 | 0.000 | -0.472 | -19.874 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18.529 | 7.937 | 2.700 | 0.000 | 0.128 | 0.000 | 0.000 | -1.159 | 0.000 | -0.506 | -27.629 |
Total Facility | 56.285 | -2176.771 | 0.000 | 0.000 | 284.665 | 416.414 | 980.287 | 1348.281 | 0.000 | 108.363 | 309.406 | 0.000 | -548.715 | 0.000 | -471.740 | -306.482 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 01-NOV-15:15 | 0.00 | -3278.66 | 0.00 | 0.00 | 48.90 | 100.83 | 470.89 | 4754.22 | 0.00 | 26.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2123.13 |
G NW APARTMENT | 28-JUN-17:20 | 0.00 | -3171.05 | 0.00 | 0.00 | 132.85 | 194.45 | 588.62 | 3748.57 | 0.00 | 145.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1638.74 |
OFFICE | 28-SEP-10:00 | 0.00 | -3820.23 | 0.00 | 0.00 | 64.91 | 1622.33 | 544.91 | 4267.99 | 0.00 | 33.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2713.90 |
G NE APARTMENT | 28-JUN-08:45 | 0.00 | -2518.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 2976.70 | 0.00 | 57.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -979.72 |
G N1 APARTMENT | 19-JUN-19:00 | 0.00 | -1684.17 | 0.00 | 0.00 | 140.06 | 230.46 | 547.42 | 854.74 | 0.00 | 85.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -174.05 |
G N2 APARTMENT | 19-JUN-19:00 | 0.00 | -1671.77 | 0.00 | 0.00 | 140.04 | 230.46 | 547.42 | 854.97 | 0.00 | 85.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -186.66 |
G S1 APARTMENT | 02-NOV-13:30 | 0.00 | -2008.88 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 3196.72 | 0.00 | 272.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1912.34 |
G S2 APARTMENT | 02-NOV-13:30 | 0.00 | -2059.25 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 3195.74 | 0.00 | 274.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1862.99 |
F2 SW APARTMENT | 01-NOV-15:15 | 0.00 | -3875.82 | 0.00 | 0.00 | 48.04 | 100.83 | 470.89 | 4614.66 | 0.00 | 35.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1394.28 |
F2 NW APARTMENT | 22-JUL-17:20 | 0.00 | -3639.01 | 0.00 | 0.00 | 139.62 | 194.45 | 588.62 | 3116.58 | 0.00 | 349.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -749.32 |
F2 SE APARTMENT | 28-SEP-10:15 | 0.00 | -3467.00 | 0.00 | 0.00 | 40.42 | 28.81 | 412.03 | 4230.44 | 0.00 | 49.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1294.18 |
F2 NE APARTMENT | 28-JUN-08:30 | 0.00 | -2970.80 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 2922.20 | 0.00 | 101.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -516.57 |
F2 N1 APARTMENT | 20-JUN-18:45 | 0.00 | -1995.17 | 0.00 | 0.00 | 141.15 | 230.46 | 547.42 | 906.93 | 0.00 | 114.23 | 55.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 N2 APARTMENT | 20-JUN-18:45 | 0.00 | -1985.80 | 0.00 | 0.00 | 141.13 | 230.46 | 547.42 | 907.05 | 0.00 | 114.21 | 45.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 S1 APARTMENT | 02-NOV-13:30 | 0.00 | -2426.79 | 0.00 | 0.00 | 40.50 | 28.81 | 382.60 | 3018.51 | 0.00 | 305.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1348.93 |
F2 S2 APARTMENT | 02-NOV-13:30 | 0.00 | -2444.43 | 0.00 | 0.00 | 40.52 | 28.81 | 382.60 | 3018.52 | 0.00 | 307.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1333.26 |
F3 SW APARTMENT | 01-NOV-15:15 | 0.00 | -3880.07 | 0.00 | 0.00 | 47.79 | 100.83 | 470.89 | 4537.47 | 0.00 | 41.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1318.18 |
F3 NW APARTMENT | 22-JUL-17:20 | 0.00 | -3642.48 | 0.00 | 0.00 | 139.60 | 194.45 | 588.62 | 3042.14 | 0.00 | 412.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -734.87 |
F3 SE APARTMENT | 09-OCT-10:45 | 0.00 | -3303.82 | 0.00 | 0.00 | 40.75 | 28.81 | 412.03 | 3702.84 | 0.00 | 226.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1106.74 |
F3 NE APARTMENT | 28-JUN-08:30 | 0.00 | -2975.31 | 0.00 | 0.00 | 40.74 | 28.81 | 394.37 | 2882.04 | 0.00 | 119.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -490.07 |
F3 N1 APARTMENT | 20-JUN-18:45 | 0.00 | -2003.37 | 0.00 | 0.00 | 140.84 | 230.46 | 547.42 | 894.67 | 0.00 | 134.38 | 55.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 N2 APARTMENT | 20-JUN-18:45 | 0.00 | -1994.30 | 0.00 | 0.00 | 140.82 | 230.46 | 547.42 | 894.78 | 0.00 | 134.36 | 46.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 S1 APARTMENT | 28-DEC-11:15 | 0.00 | -2531.24 | 0.00 | 0.00 | 40.75 | 28.81 | 412.03 | 3318.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -14.14 | -1254.96 |
F3 S2 APARTMENT | 28-DEC-11:15 | 0.00 | -2539.91 | 0.00 | 0.00 | 40.75 | 28.81 | 412.03 | 3318.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -14.14 | -1246.16 |
F4 SW APARTMENT | 01-NOV-15:15 | 0.00 | -3883.71 | 0.00 | 0.00 | 47.86 | 100.83 | 470.89 | 4483.48 | 0.00 | 46.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1265.49 |
F4 NW APARTMENT | 22-JUL-17:20 | 0.00 | -3661.43 | 0.00 | 0.00 | 139.63 | 194.45 | 588.62 | 2990.59 | 0.00 | 460.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -712.31 |
F4 SE APARTMENT | 09-OCT-10:45 | 0.00 | -3302.45 | 0.00 | 0.00 | 40.75 | 28.81 | 412.03 | 3669.19 | 0.00 | 235.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1084.04 |
F4 NE APARTMENT | 28-JUN-08:30 | 0.00 | -2977.55 | 0.00 | 0.00 | 40.74 | 28.81 | 394.37 | 2851.93 | 0.00 | 133.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -471.45 |
F4 N1 APARTMENT | 19-JUN-19:00 | 0.00 | -2015.50 | 0.00 | 0.00 | 139.07 | 230.46 | 547.42 | 822.36 | 0.00 | 159.63 | 116.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 N2 APARTMENT | 19-JUN-19:00 | 0.00 | -2006.62 | 0.00 | 0.00 | 139.02 | 230.46 | 547.42 | 822.31 | 0.00 | 159.55 | 107.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 S1 APARTMENT | 28-DEC-11:15 | 0.00 | -2575.74 | 0.00 | 0.00 | 40.75 | 28.81 | 412.03 | 3311.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -15.84 | -1201.93 |
F4 S2 APARTMENT | 28-DEC-11:15 | 0.00 | -2583.30 | 0.00 | 0.00 | 40.75 | 28.81 | 412.03 | 3311.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -15.84 | -1194.24 |
M SW APARTMENT | 01-NOV-15:15 | 0.00 | -3912.04 | 0.00 | 0.00 | 47.97 | 100.83 | 470.89 | 4439.50 | 0.00 | 50.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1197.54 |
M NW APARTMENT | 22-JUL-17:20 | 0.00 | -3699.21 | 0.00 | 0.00 | 139.54 | 194.45 | 588.62 | 2949.63 | 0.00 | 499.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -672.35 |
M SE APARTMENT | 09-OCT-10:45 | 0.00 | -3337.21 | 0.00 | 0.00 | 40.75 | 28.81 | 412.03 | 3640.66 | 0.00 | 245.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1030.36 |
M NE APARTMENT | 28-JUN-08:30 | 0.00 | -3007.81 | 0.00 | 0.00 | 40.74 | 28.81 | 394.37 | 2826.47 | 0.00 | 144.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -426.96 |
M N1 APARTMENT | 19-JUN-19:00 | 0.00 | -2053.42 | 0.00 | 0.00 | 138.99 | 230.46 | 547.42 | 817.82 | 0.00 | 172.96 | 145.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 19-JUN-19:00 | 0.00 | -2044.77 | 0.00 | 0.00 | 138.93 | 230.46 | 547.42 | 817.72 | 0.00 | 172.86 | 137.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | 28-DEC-11:15 | 0.00 | -2606.57 | 0.00 | 0.00 | 40.75 | 28.81 | 412.03 | 3305.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -17.25 | -1163.71 |
M S2 APARTMENT | 28-DEC-11:15 | 0.00 | -2613.95 | 0.00 | 0.00 | 40.75 | 28.81 | 412.03 | 3305.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -17.25 | -1156.22 |
F6 SW APARTMENT | 01-NOV-15:15 | 0.00 | -3872.97 | 0.00 | 0.00 | 48.09 | 100.83 | 470.89 | 4403.88 | 0.00 | 54.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1204.80 |
F6 NW APARTMENT | 22-JUL-17:20 | 0.00 | -3655.35 | 0.00 | 0.00 | 139.31 | 194.45 | 588.62 | 2917.36 | 0.00 | 531.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -716.15 |
F6 SE APARTMENT | 09-OCT-10:45 | 0.00 | -3290.41 | 0.00 | 0.00 | 40.75 | 28.81 | 412.03 | 3617.93 | 0.00 | 252.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1061.53 |
F6 NE APARTMENT | 28-JUN-08:30 | 0.00 | -2965.66 | 0.00 | 0.00 | 40.73 | 28.81 | 394.37 | 2806.31 | 0.00 | 153.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -458.40 |
F6 N1 APARTMENT | 22-JUL-17:20 | 0.00 | -2021.30 | 0.00 | 0.00 | 139.11 | 194.45 | 588.62 | 972.06 | 0.00 | 320.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -193.16 |
F6 N2 APARTMENT | 22-JUL-17:20 | 0.00 | -2013.30 | 0.00 | 0.00 | 139.05 | 194.45 | 588.62 | 971.97 | 0.00 | 320.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -200.88 |
F6 S1 APARTMENT | 28-DEC-11:15 | 0.00 | -2556.97 | 0.00 | 0.00 | 40.75 | 28.81 | 412.03 | 3302.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -18.47 | -1208.20 |
F6 S2 APARTMENT | 28-DEC-11:15 | 0.00 | -2564.13 | 0.00 | 0.00 | 40.75 | 28.81 | 412.03 | 3301.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -18.47 | -1200.92 |
F7 SW APARTMENT | 01-NOV-15:15 | 0.00 | -3856.81 | 0.00 | 0.00 | 48.19 | 100.83 | 470.89 | 4371.96 | 0.00 | 57.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1192.42 |
F7 NW APARTMENT | 22-JUL-17:20 | 0.00 | -3640.11 | 0.00 | 0.00 | 139.14 | 194.45 | 588.62 | 2889.52 | 0.00 | 560.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -731.90 |
F7 SE APARTMENT | 09-OCT-10:45 | 0.00 | -3266.72 | 0.00 | 0.00 | 40.75 | 28.81 | 412.03 | 3597.08 | 0.00 | 258.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1070.35 |
F7 NE APARTMENT | 28-JUN-08:30 | 0.00 | -2953.13 | 0.00 | 0.00 | 40.73 | 28.81 | 394.37 | 2788.05 | 0.00 | 162.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -461.03 |
F7 N1 APARTMENT | 22-JUL-17:20 | 0.00 | -2018.05 | 0.00 | 0.00 | 138.92 | 194.45 | 588.62 | 967.79 | 0.00 | 337.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -209.14 |
F7 N2 APARTMENT | 22-JUL-17:20 | 0.00 | -2009.36 | 0.00 | 0.00 | 138.86 | 194.45 | 588.62 | 967.67 | 0.00 | 337.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -217.48 |
F7 S1 APARTMENT | 28-DEC-11:15 | 0.00 | -2526.12 | 0.00 | 0.00 | 40.75 | 28.81 | 412.03 | 3298.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -19.56 | -1233.97 |
F7 S2 APARTMENT | 28-DEC-11:15 | 0.00 | -2533.09 | 0.00 | 0.00 | 40.75 | 28.81 | 412.03 | 3297.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -19.56 | -1226.89 |
F8 SW APARTMENT | 01-NOV-15:15 | 0.00 | -3855.74 | 0.00 | 0.00 | 48.33 | 100.83 | 470.89 | 4343.84 | 0.00 | 60.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1168.64 |
F8 NW APARTMENT | 22-JUL-17:20 | 0.00 | -3642.40 | 0.00 | 0.00 | 139.00 | 194.45 | 588.62 | 2864.96 | 0.00 | 585.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -730.51 |
F8 SE APARTMENT | 05-OCT-09:15 | 0.00 | -3270.90 | 0.00 | 0.00 | 40.68 | 28.81 | 406.15 | 3958.24 | 0.00 | 229.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1392.23 |
F8 NE APARTMENT | 28-JUN-08:30 | 0.00 | -2956.99 | 0.00 | 0.00 | 40.72 | 28.81 | 394.37 | 2771.16 | 0.00 | 169.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -447.73 |
F8 N1 APARTMENT | 22-JUL-17:45 | 0.00 | -2029.07 | 0.00 | 0.00 | 138.09 | 194.45 | 588.62 | 990.06 | 0.00 | 359.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -241.52 |
F8 N2 APARTMENT | 22-JUL-17:45 | 0.00 | -2021.31 | 0.00 | 0.00 | 138.03 | 194.45 | 588.62 | 989.99 | 0.00 | 359.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -249.03 |
F8 S1 APARTMENT | 28-DEC-11:15 | 0.00 | -2491.31 | 0.00 | 0.00 | 40.75 | 28.81 | 412.03 | 3294.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -20.55 | -1264.20 |
F8 S2 APARTMENT | 28-DEC-11:15 | 0.00 | -2498.12 | 0.00 | 0.00 | 40.75 | 28.81 | 412.03 | 3294.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -20.55 | -1257.28 |
F9 SW APARTMENT | 01-NOV-15:15 | 0.00 | -3936.37 | 0.00 | 0.00 | 48.64 | 100.83 | 470.89 | 4320.15 | 0.00 | 64.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1068.46 |
F9 NW APARTMENT | 22-JUL-17:20 | 0.00 | -3744.25 | 0.00 | 0.00 | 139.08 | 194.45 | 588.62 | 2840.88 | 0.00 | 610.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -628.87 |
F9 SE APARTMENT | 28-SEP-10:15 | 0.00 | -3321.49 | 0.00 | 0.00 | 40.56 | 28.81 | 412.03 | 4012.11 | 0.00 | 86.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1258.68 |
F9 NE APARTMENT | 28-JUN-08:30 | 0.00 | -3009.82 | 0.00 | 0.00 | 40.74 | 28.81 | 394.37 | 2754.62 | 0.00 | 176.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -385.35 |
F9 N1 APARTMENT | 22-JUL-17:45 | 0.00 | -2128.82 | 0.00 | 0.00 | 138.30 | 194.45 | 588.62 | 985.03 | 0.00 | 374.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -152.22 |
F9 N2 APARTMENT | 22-JUL-17:45 | 0.00 | -2121.09 | 0.00 | 0.00 | 138.25 | 194.45 | 588.62 | 984.96 | 0.00 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -159.71 |
F9 S1 APARTMENT | 02-NOV-13:30 | 0.00 | -2534.75 | 0.00 | 0.00 | 40.71 | 28.81 | 382.60 | 2666.37 | 0.00 | 494.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1078.45 |
F9 S2 APARTMENT | 02-NOV-13:30 | 0.00 | -2540.56 | 0.00 | 0.00 | 40.71 | 28.81 | 382.60 | 2666.38 | 0.00 | 495.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1073.68 |
T SW APARTMENT | 05-OCT-15:15 | 0.00 | -4595.46 | 0.00 | 0.00 | 47.31 | 100.83 | 470.89 | 4324.64 | 0.00 | 39.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -387.58 |
T NW APARTMENT | 22-JUL-17:30 | 0.00 | -4404.37 | 0.00 | 0.00 | 141.01 | 194.45 | 588.62 | 2792.21 | 0.00 | 639.79 | 48.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SE APARTMENT | 28-SEP-10:45 | 0.00 | -4010.79 | 0.00 | 0.00 | 40.55 | 28.81 | 412.03 | 4022.74 | 0.00 | 88.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -581.96 |
T NE APARTMENT | 22-JUL-18:00 | 0.00 | -3526.45 | 0.00 | 0.00 | 141.22 | 194.45 | 588.62 | 1397.75 | 0.00 | 676.07 | 528.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 22-JUL-17:20 | 0.00 | -2615.15 | 0.00 | 0.00 | 140.00 | 194.45 | 588.62 | 942.95 | 0.00 | 383.95 | 365.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 11-JUL-17:30 | 0.00 | -2638.79 | 0.00 | 0.00 | 139.95 | 194.45 | 588.62 | 965.83 | 0.00 | 292.66 | 457.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 02-NOV-13:45 | 0.00 | -3177.70 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 2521.22 | 0.00 | 623.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -419.07 |
T S2 APARTMENT | 02-NOV-13:45 | 0.00 | -3178.22 | 0.00 | 0.00 | 40.75 | 28.81 | 382.60 | 2521.17 | 0.00 | 623.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -418.50 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 22-JUL-17:20 | 0.00 | -215965.55 | 0.00 | 0.00 | 11107.29 | 22204.40 | 47141.46 | 118819.00 | 0.00 | 34012.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -17318.71 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 07-DEC-05:00 | 680.70 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 360.56 | 0.00 | -1347.99 | 0.00 | -149.82 | 0.00 |
G NW APARTMENT | 07-DEC-05:00 | 941.76 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 86.81 | 0.00 | -1335.30 | 0.00 | -149.82 | 0.00 |
OFFICE | 07-DEC-06:00 | 726.33 | 0.00 | 0.00 | 0.00 | 0.00 | 379.58 | 128.69 | 0.00 | 0.00 | 0.00 | 253.65 | 0.00 | -1339.15 | 0.00 | -149.11 | 0.00 |
G NE APARTMENT | 07-DEC-05:00 | 951.76 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 70.12 | 0.00 | -1328.61 | 0.00 | -149.82 | 0.00 |
G N1 APARTMENT | 06-DEC-14:40 | 903.24 | 0.00 | 0.00 | 0.00 | 46.31 | 28.81 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -5.16 | 0.00 | -885.37 | -470.43 |
G N2 APARTMENT | 06-DEC-14:40 | 897.32 | 0.00 | 0.00 | 0.00 | 46.29 | 28.81 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -5.33 | 0.00 | -885.75 | -463.94 |
G S1 APARTMENT | 10-FEB-13:45 | 628.73 | 0.00 | 0.00 | 0.00 | 44.72 | 28.81 | 388.49 | 45.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -954.18 | -181.72 |
G S2 APARTMENT | 10-FEB-13:45 | 468.04 | 0.00 | 0.00 | 0.00 | 44.49 | 28.81 | 388.49 | 42.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -961.15 | -10.72 |
F2 SW APARTMENT | 16-MAR-07:40 | 439.62 | 0.00 | 0.00 | 0.00 | 63.57 | 43.21 | 388.49 | 0.00 | 0.00 | 0.00 | 864.37 | 0.00 | -140.13 | 0.00 | -1659.13 | 0.00 |
F2 NW APARTMENT | 07-DEC-05:00 | 833.93 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 302.11 | 0.00 | -1377.10 | 0.00 | -215.49 | 0.00 |
F2 SE APARTMENT | 07-NOV-09:10 | 379.94 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 110.31 | 0.00 | 0.00 | 596.00 | 0.00 | 0.00 | 0.00 | -1550.18 | 0.00 |
F2 NE APARTMENT | 07-DEC-05:00 | 845.69 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 286.19 | 0.00 | -1372.95 | 0.00 | -215.49 | 0.00 |
F2 N1 APARTMENT | 09-DEC-10:45 | 677.01 | 0.00 | 0.00 | 0.00 | 45.37 | 28.81 | 406.15 | 12.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -928.28 | -242.00 |
F2 N2 APARTMENT | 09-DEC-10:45 | 651.55 | 0.00 | 0.00 | 0.00 | 45.33 | 28.81 | 406.15 | 12.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -929.23 | -214.89 |
F2 S1 APARTMENT | 08-MAR-09:40 | 180.88 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 588.42 | 0.00 | 0.00 | 432.82 | 0.00 | 0.00 | 0.00 | -1666.05 | 0.00 |
F2 S2 APARTMENT | 08-MAR-09:40 | 184.18 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 588.18 | 0.00 | 0.00 | 430.33 | 0.00 | 0.00 | 0.00 | -1666.62 | 0.00 |
F3 SW APARTMENT | 08-MAR-09:40 | 488.65 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 637.78 | 0.00 | 0.00 | 302.90 | 0.00 | 0.00 | 0.00 | -1893.26 | 0.00 |
F3 NW APARTMENT | 07-DEC-05:00 | 794.36 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 402.68 | 0.00 | -1398.29 | 0.00 | -255.30 | 0.00 |
F3 SE APARTMENT | 08-MAR-09:40 | 361.67 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 1066.28 | 0.00 | 0.00 | 39.51 | 0.00 | 0.00 | 0.00 | -1931.39 | 0.00 |
F3 NE APARTMENT | 07-DEC-05:00 | 804.15 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 390.98 | 0.00 | -1396.38 | 0.00 | -255.30 | 0.00 |
F3 N1 APARTMENT | 09-DEC-10:45 | 533.13 | 0.00 | 0.00 | 0.00 | 44.94 | 28.81 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1.30 | 0.00 | -1002.64 | -9.09 |
F3 N2 APARTMENT | 09-DEC-10:45 | 509.88 | 0.00 | 0.00 | 0.00 | 44.90 | 28.81 | 406.15 | 0.00 | 0.00 | 0.00 | 15.72 | 0.00 | -1.95 | 0.00 | -1003.50 | 0.00 |
F3 S1 APARTMENT | 08-MAR-09:40 | 195.69 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 536.03 | 0.00 | 0.00 | 620.90 | 0.00 | 0.00 | 0.00 | -1816.56 | 0.00 |
F3 S2 APARTMENT | 08-MAR-09:40 | 197.36 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 536.11 | 0.00 | 0.00 | 618.96 | 0.00 | 0.00 | 0.00 | -1816.36 | 0.00 |
F4 SW APARTMENT | 08-MAR-09:40 | 495.83 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 599.18 | 0.00 | 0.00 | 465.95 | 0.00 | 0.00 | 0.00 | -2024.89 | 0.00 |
F4 NW APARTMENT | 07-DEC-05:00 | 807.18 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 433.36 | 0.00 | -1411.55 | 0.00 | -285.55 | 0.00 |
F4 SE APARTMENT | 08-MAR-09:40 | 381.22 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 1009.64 | 0.00 | 0.00 | 190.75 | 0.00 | 0.00 | 0.00 | -2045.54 | 0.00 |
F4 NE APARTMENT | 07-DEC-05:00 | 814.28 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 426.19 | 0.00 | -1411.48 | 0.00 | -285.55 | 0.00 |
F4 N1 APARTMENT | 10-FEB-13:45 | 766.90 | 0.00 | 0.00 | 0.00 | 43.52 | 28.81 | 388.49 | 0.00 | 0.00 | 0.00 | 13.31 | 0.00 | -35.01 | 0.00 | -1206.01 | 0.00 |
F4 N2 APARTMENT | 10-FEB-13:45 | 690.33 | 0.00 | 0.00 | 0.00 | 43.52 | 28.81 | 388.49 | 0.00 | 0.00 | 0.00 | 91.33 | 0.00 | -35.15 | 0.00 | -1207.32 | 0.00 |
F4 S1 APARTMENT | 08-MAR-09:40 | 203.94 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 503.62 | 0.00 | 0.00 | 768.46 | 0.00 | 0.00 | 0.00 | -1939.94 | 0.00 |
F4 S2 APARTMENT | 08-MAR-09:40 | 205.98 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 503.80 | 0.00 | 0.00 | 764.75 | 0.00 | 0.00 | 0.00 | -1938.46 | 0.00 |
M SW APARTMENT | 08-MAR-09:40 | 516.65 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 570.19 | 0.00 | 0.00 | 575.98 | 0.00 | 0.00 | 0.00 | -2126.75 | 0.00 |
M NW APARTMENT | 07-DEC-05:00 | 814.65 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 461.27 | 0.00 | -1421.94 | 0.00 | -310.53 | 0.00 |
M SE APARTMENT | 08-MAR-09:40 | 405.45 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 966.66 | 0.00 | 0.00 | 305.05 | 0.00 | 0.00 | 0.00 | -2141.09 | 0.00 |
M NE APARTMENT | 07-DEC-05:00 | 823.50 | 0.00 | 0.00 | 0.00 | 189.67 | 43.21 | 223.68 | 0.00 | 0.00 | 0.00 | 453.94 | 0.00 | -1423.47 | 0.00 | -310.53 | 0.00 |
M N1 APARTMENT | 11-MAR-16:15 | 680.35 | 0.00 | 0.00 | 0.00 | 51.03 | 100.83 | 470.89 | 0.00 | 0.00 | 0.00 | 603.08 | 0.00 | -64.05 | 0.00 | -1842.12 | 0.00 |
M N2 APARTMENT | 11-MAR-16:15 | 705.89 | 0.00 | 0.00 | 0.00 | 51.07 | 100.83 | 470.89 | 0.00 | 0.00 | 0.00 | 576.16 | 0.00 | -63.52 | 0.00 | -1841.32 | 0.00 |
M S1 APARTMENT | 08-MAR-09:40 | 220.50 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 479.48 | 0.00 | 0.00 | 872.82 | 0.00 | 0.00 | 0.00 | -2036.73 | 0.00 |
M S2 APARTMENT | 08-MAR-09:40 | 222.69 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 479.69 | 0.00 | 0.00 | 868.53 | 0.00 | 0.00 | 0.00 | -2034.84 | 0.00 |
F6 SW APARTMENT | 08-MAR-09:40 | 546.19 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 552.09 | 0.00 | 0.00 | 617.15 | 0.00 | 0.00 | 0.00 | -2179.37 | 0.00 |
F6 NW APARTMENT | 09-DEC-10:45 | 947.85 | 0.00 | 0.00 | 0.00 | 45.42 | 28.81 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -10.51 | 0.00 | -1196.67 | -221.05 |
F6 SE APARTMENT | 08-MAR-09:40 | 436.05 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 937.25 | 0.00 | 0.00 | 352.14 | 0.00 | 0.00 | 0.00 | -2189.36 | 0.00 |
F6 NE APARTMENT | 03-FEB-13:45 | 1327.59 | 0.00 | 0.00 | 0.00 | 42.82 | 28.81 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -13.97 | 0.00 | -1696.19 | -77.54 |
F6 N1 APARTMENT | 11-MAR-16:15 | 1131.04 | 0.00 | 0.00 | 0.00 | 51.52 | 100.83 | 470.89 | 0.00 | 0.00 | 0.00 | 244.13 | 0.00 | -62.79 | 0.00 | -1935.62 | 0.00 |
F6 N2 APARTMENT | 11-MAR-16:15 | 1157.43 | 0.00 | 0.00 | 0.00 | 51.56 | 100.83 | 470.89 | 0.00 | 0.00 | 0.00 | 216.36 | 0.00 | -62.24 | 0.00 | -1934.84 | 0.00 |
F6 S1 APARTMENT | 08-MAR-09:40 | 241.58 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 463.05 | 0.00 | 0.00 | 912.81 | 0.00 | 0.00 | 0.00 | -2081.36 | 0.00 |
F6 S2 APARTMENT | 08-MAR-09:40 | 244.33 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 463.30 | 0.00 | 0.00 | 906.88 | 0.00 | 0.00 | 0.00 | -2078.43 | 0.00 |
F7 SW APARTMENT | 08-MAR-09:40 | 557.98 | 0.00 | 0.00 | 0.00 | 40.77 | 28.81 | 394.37 | 537.01 | 0.00 | 0.00 | 681.29 | 0.00 | 0.00 | 0.00 | -2240.23 | 0.00 |
F7 NW APARTMENT | 03-JAN-09:45 | 1119.67 | 0.00 | 0.00 | 0.00 | 44.89 | 28.81 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -155.63 | 0.00 | -1349.16 | -82.96 |
F7 SE APARTMENT | 08-MAR-09:40 | 453.23 | 0.00 | 0.00 | 0.00 | 40.76 | 28.81 | 394.37 | 913.06 | 0.00 | 0.00 | 413.48 | 0.00 | 0.00 | 0.00 | -2243.72 | 0.00 |
F7 NE APARTMENT | 03-FEB-13:45 | 1632.57 | 0.00 | 0.00 | 0.00 | 43.24 | 28.81 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -15.02 | 0.00 | -1759.58 | -318.50 |
F7 N1 APARTMENT | 11-MAR-16:15 | 1519.10 | 0.00 | 0.00 | 0.00 | 51.88 | 100.83 | 470.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -62.53 | 0.00 | -2021.86 | -58.31 |
F7 N2 APARTMENT | 11-MAR-16:15 | 1544.19 | 0.00 | 0.00 | 0.00 | 51.92 | 100.83 | 470.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -62.06 | 0.00 | -2021.17 | -84.61 |
F7 S1 APARTMENT | 08-MAR-09:40 | 268.34 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 449.29 | 0.00 | 0.00 | 930.60 | 0.00 | 0.00 | 0.00 | -2112.16 | 0.00 |
F7 S2 APARTMENT | 08-MAR-09:40 | 268.02 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 449.57 | 0.00 | 0.00 | 933.61 | 0.00 | 0.00 | 0.00 | -2115.13 | 0.00 |
F8 SW APARTMENT | 08-MAR-09:40 | 564.78 | 0.00 | 0.00 | 0.00 | 40.97 | 28.81 | 394.37 | 526.55 | 0.00 | 0.00 | 726.68 | 0.00 | 0.00 | 0.00 | -2282.16 | 0.00 |
F8 NW APARTMENT | 03-FEB-13:45 | 1285.99 | 0.00 | 0.00 | 0.00 | 43.69 | 28.81 | 388.49 | 464.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1833.74 | -378.20 |
F8 SE APARTMENT | 10-FEB-12:30 | 506.51 | 0.00 | 0.00 | 0.00 | 47.38 | 28.81 | 406.15 | 0.00 | 0.00 | 0.00 | 926.21 | 0.00 | -110.76 | 0.00 | -1804.29 | 0.00 |
F8 NE APARTMENT | 03-FEB-13:45 | 1577.86 | 0.00 | 0.00 | 0.00 | 43.64 | 28.81 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -14.73 | 0.00 | -1827.65 | -196.42 |
F8 N1 APARTMENT | 03-FEB-13:45 | 1569.04 | 0.00 | 0.00 | 0.00 | 43.32 | 28.81 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -12.40 | 0.00 | -1749.98 | -267.26 |
F8 N2 APARTMENT | 03-FEB-13:45 | 1585.42 | 0.00 | 0.00 | 0.00 | 43.29 | 28.81 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -12.90 | 0.00 | -1750.01 | -283.09 |
F8 S1 APARTMENT | 08-MAR-09:45 | 627.33 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 437.85 | 0.00 | 0.00 | 384.33 | 0.00 | 0.00 | 0.00 | -1913.44 | 0.00 |
F8 S2 APARTMENT | 08-MAR-09:45 | 713.26 | 0.00 | 0.00 | 0.00 | 40.75 | 28.81 | 394.37 | 438.18 | 0.00 | 0.00 | 296.94 | 0.00 | 0.00 | 0.00 | -1912.32 | 0.00 |
F9 SW APARTMENT | 08-MAR-09:45 | 884.66 | 0.00 | 0.00 | 0.00 | 41.59 | 28.81 | 394.37 | 526.91 | 0.00 | 0.00 | 201.50 | 0.00 | 0.00 | 0.00 | -2077.84 | 0.00 |
F9 NW APARTMENT | 08-MAR-09:45 | 1403.70 | 0.00 | 0.00 | 0.00 | 43.32 | 28.81 | 394.37 | 246.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1870.78 | -246.01 |
F9 SE APARTMENT | 08-MAR-09:45 | 671.44 | 0.00 | 0.00 | 0.00 | 41.51 | 28.81 | 394.37 | 889.24 | 0.00 | 0.00 | 50.21 | 0.00 | 0.00 | 0.00 | -2075.58 | 0.00 |
F9 NE APARTMENT | 03-FEB-13:45 | 1555.89 | 0.00 | 0.00 | 0.00 | 44.17 | 28.81 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -9.01 | 0.00 | -1891.08 | -117.27 |
F9 N1 APARTMENT | 11-MAR-16:15 | 1592.44 | 0.00 | 0.00 | 0.00 | 52.23 | 100.83 | 470.89 | 0.00 | 0.00 | 0.00 | 40.07 | 0.00 | -64.98 | 0.00 | -2191.48 | 0.00 |
F9 N2 APARTMENT | 11-MAR-16:15 | 1591.39 | 0.00 | 0.00 | 0.00 | 52.26 | 100.83 | 470.89 | 0.00 | 0.00 | 0.00 | 40.62 | 0.00 | -64.58 | 0.00 | -2191.41 | 0.00 |
F9 S1 APARTMENT | 11-MAR-16:15 | 755.50 | 0.00 | 0.00 | 0.00 | 49.24 | 100.83 | 470.89 | 255.90 | 0.00 | 0.00 | 591.63 | 0.00 | 0.00 | 0.00 | -2223.99 | 0.00 |
F9 S2 APARTMENT | 11-MAR-16:15 | 773.95 | 0.00 | 0.00 | 0.00 | 49.26 | 100.83 | 470.89 | 256.14 | 0.00 | 0.00 | 572.57 | 0.00 | 0.00 | 0.00 | -2223.64 | 0.00 |
T SW APARTMENT | 08-MAR-09:45 | 1531.83 | 0.00 | 0.00 | 0.00 | 42.85 | 28.81 | 394.37 | 548.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2124.60 | -421.86 |
T NW APARTMENT | 22-NOV-06:45 | 1751.41 | 0.00 | 0.00 | 0.00 | 170.17 | 100.83 | 317.85 | 0.00 | 0.00 | 0.00 | 237.89 | 0.00 | -556.75 | 0.00 | -2021.41 | 0.00 |
T SE APARTMENT | 22-NOV-06:45 | 1540.79 | 0.00 | 0.00 | 0.00 | 168.84 | 100.83 | 317.85 | 0.00 | 0.00 | 0.00 | 477.30 | 0.00 | -579.67 | 0.00 | -2025.94 | 0.00 |
T NE APARTMENT | 03-FEB-13:45 | 1805.46 | 0.00 | 0.00 | 0.00 | 42.98 | 28.81 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -44.51 | 0.00 | -1958.73 | -262.49 |
T N1 APARTMENT | 03-FEB-13:45 | 1697.36 | 0.00 | 0.00 | 0.00 | 43.37 | 28.81 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -16.53 | 0.00 | -1871.59 | -269.90 |
T N2 APARTMENT | 03-FEB-13:45 | 1729.80 | 0.00 | 0.00 | 0.00 | 43.23 | 28.81 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -18.88 | 0.00 | -1871.92 | -299.53 |
T S1 APARTMENT | 08-MAR-09:45 | 1306.66 | 0.00 | 0.00 | 0.00 | 42.00 | 28.81 | 394.37 | 442.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2032.50 | -181.84 |
T S2 APARTMENT | 08-MAR-09:45 | 1302.38 | 0.00 | 0.00 | 0.00 | 42.01 | 28.81 | 394.37 | 442.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2032.55 | -177.66 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 10-FEB-13:45 | 47625.91 | 0.00 | 0.00 | 0.00 | 3498.75 | 10361.29 | 31389.06 | 418.19 | 0.00 | 0.00 | 16284.66 | 0.00 | -3939.73 | 0.00 | -105638.13 | 0.00 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:11
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:11
Sec1.1A-General InformationData | |
Weather File | Tucson-Davis Monthan AFB AZ USA TMY3 WMO#=722745 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 7836.48 |
Principal Heating Source | Electricity |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.50 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F2 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F3 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F4 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F6 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F7 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F8 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F9 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 7836.48 | 7059.89 | 776.58 |
Data | |
Number of hours heating loads not met | 10.75 |
Number of hours cooling loads not met | 640.00 |
Number of hours not met | 650.75 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 416.41 | 25049.15 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 168.51 | 10720.10 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 4.73 | 0.00 | 2.88 | 27346.18 | 0.00 | 0.00 |
Space Cooling | 908.06 | 71861.98 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 52.12 | 1697.55 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 33.55 | 2260.76 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 770.14 | 24420.97 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 0.00 | 0.00 | 899.03 | 78424.24 | 0.00 | 0.00 |
Receptacle Equipment | 1131.09 | 49704.83 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 3505.44 | 901.91 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 1131.09 | 3505.44 |
Natural Gas | 0.00 | 901.91 |
Additional | 0.00 | 0.00 |
Total | 1131.09 | 4407.35 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 53.14 |
Space Heating | 0.60 |
Space Cooling | 115.88 |
Fans-Interior | 98.28 |
Service Water Heating | 0.00 |
Receptacle Equipment | 144.34 |
Miscellaneous | 35.09 |
Subtotal | 447.32 |
Natural Gas [MJ/m2] | |
Space Heating | 0.37 |
Service Water Heating | 114.72 |
Miscellaneous | -0.00 |
Subtotal | 115.09 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 9.45 |
Space Heating | 0.17 |
Space Cooling | 20.60 |
Fans-Interior | 17.47 |
Service Water Heating | 20.40 |
Receptacle Equipment | 25.66 |
Miscellaneous | 6.24 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:11
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.308247 |
G NW APARTMENT DIRECT AIR | 0.305369 |
OFFICE DIRECT AIR | 0.369788 |
G NE APARTMENT DIRECT AIR | 0.244620 |
G N1 APARTMENT DIRECT AIR | 0.166075 |
G N2 APARTMENT DIRECT AIR | 0.164931 |
G S1 APARTMENT DIRECT AIR | 0.173846 |
G S2 APARTMENT DIRECT AIR | 0.178861 |
F2 SW APARTMENT DIRECT AIR | 0.357233 |
F2 NW APARTMENT DIRECT AIR | 0.353052 |
F2 SE APARTMENT DIRECT AIR | 0.323198 |
F2 NE APARTMENT DIRECT AIR | 0.288049 |
F2 N1 APARTMENT DIRECT AIR | 0.195840 |
F2 N2 APARTMENT DIRECT AIR | 0.194951 |
F2 S1 APARTMENT DIRECT AIR | 0.207052 |
F2 S2 APARTMENT DIRECT AIR | 0.208798 |
F3 SW APARTMENT DIRECT AIR | 0.357064 |
F3 NW APARTMENT DIRECT AIR | 0.353034 |
F3 SE APARTMENT DIRECT AIR | 0.308211 |
F3 NE APARTMENT DIRECT AIR | 0.290016 |
F3 N1 APARTMENT DIRECT AIR | 0.197810 |
F3 N2 APARTMENT DIRECT AIR | 0.196945 |
F3 S1 APARTMENT DIRECT AIR | 0.209441 |
F3 S2 APARTMENT DIRECT AIR | 0.210212 |
F4 SW APARTMENT DIRECT AIR | 0.358276 |
F4 NW APARTMENT DIRECT AIR | 0.354141 |
F4 SE APARTMENT DIRECT AIR | 0.308207 |
F4 NE APARTMENT DIRECT AIR | 0.291535 |
F4 N1 APARTMENT DIRECT AIR | 0.199845 |
F4 N2 APARTMENT DIRECT AIR | 0.198995 |
F4 S1 APARTMENT DIRECT AIR | 0.211446 |
F4 S2 APARTMENT DIRECT AIR | 0.212074 |
M SW APARTMENT DIRECT AIR | 0.361971 |
M NW APARTMENT DIRECT AIR | 0.357856 |
M SE APARTMENT DIRECT AIR | 0.312053 |
M NE APARTMENT DIRECT AIR | 0.295504 |
M N1 APARTMENT DIRECT AIR | 0.204131 |
M N2 APARTMENT DIRECT AIR | 0.203294 |
M S1 APARTMENT DIRECT AIR | 0.215637 |
M S2 APARTMENT DIRECT AIR | 0.216242 |
F6 SW APARTMENT DIRECT AIR | 0.358915 |
F6 NW APARTMENT DIRECT AIR | 0.354634 |
F6 SE APARTMENT DIRECT AIR | 0.309392 |
F6 NE APARTMENT DIRECT AIR | 0.292596 |
F6 N1 APARTMENT DIRECT AIR | 0.201601 |
F6 N2 APARTMENT DIRECT AIR | 0.200778 |
F6 S1 APARTMENT DIRECT AIR | 0.213173 |
F6 S2 APARTMENT DIRECT AIR | 0.213773 |
F7 SW APARTMENT DIRECT AIR | 0.358318 |
F7 NW APARTMENT DIRECT AIR | 0.353977 |
F7 SE APARTMENT DIRECT AIR | 0.309113 |
F7 NE APARTMENT DIRECT AIR | 0.292178 |
F7 N1 APARTMENT DIRECT AIR | 0.201449 |
F7 N2 APARTMENT DIRECT AIR | 0.200638 |
F7 S1 APARTMENT DIRECT AIR | 0.212998 |
F7 S2 APARTMENT DIRECT AIR | 0.213595 |
F8 SW APARTMENT DIRECT AIR | 0.359271 |
F8 NW APARTMENT DIRECT AIR | 0.354876 |
F8 SE APARTMENT DIRECT AIR | 0.310304 |
F8 NE APARTMENT DIRECT AIR | 0.293227 |
F8 N1 APARTMENT DIRECT AIR | 0.202779 |
F8 N2 APARTMENT DIRECT AIR | 0.201980 |
F8 S1 APARTMENT DIRECT AIR | 0.214261 |
F8 S2 APARTMENT DIRECT AIR | 0.214857 |
F9 SW APARTMENT DIRECT AIR | 0.369403 |
F9 NW APARTMENT DIRECT AIR | 0.365061 |
F9 SE APARTMENT DIRECT AIR | 0.316799 |
F9 NE APARTMENT DIRECT AIR | 0.299036 |
F9 N1 APARTMENT DIRECT AIR | 0.212448 |
F9 N2 APARTMENT DIRECT AIR | 0.211654 |
F9 S1 APARTMENT DIRECT AIR | 0.221718 |
F9 S2 APARTMENT DIRECT AIR | 0.222303 |
T SW APARTMENT DIRECT AIR | 0.435450 |
T NW APARTMENT DIRECT AIR | 0.427665 |
T SE APARTMENT DIRECT AIR | 0.377450 |
T NE APARTMENT DIRECT AIR | 0.348745 |
T N1 APARTMENT DIRECT AIR | 0.257880 |
T N2 APARTMENT DIRECT AIR | 0.256570 |
T S1 APARTMENT DIRECT AIR | 0.288532 |
T S2 APARTMENT DIRECT AIR | 0.289089 |
Maximum Flow Rate [m3/s] | |
AIRLOOP G SW MAIN BRANCH | 0.308247 |
AIRLOOP G NW MAIN BRANCH | 0.305369 |
AIRLOOP OFFICE MAIN BRANCH | 0.369788 |
AIRLOOP G NE MAIN BRANCH | 0.244620 |
AIRLOOP G N1 MAIN BRANCH | 0.166075 |
AIRLOOP G N2 MAIN BRANCH | 0.164931 |
AIRLOOP G S1 MAIN BRANCH | 0.173846 |
AIRLOOP G S2 MAIN BRANCH | 0.178861 |
AIRLOOP F2 SW MAIN BRANCH | 0.357233 |
AIRLOOP F2 NW MAIN BRANCH | 0.353052 |
AIRLOOP F2 SE MAIN BRANCH | 0.323198 |
AIRLOOP F2 NE MAIN BRANCH | 0.288049 |
AIRLOOP F2 N1 MAIN BRANCH | 0.195840 |
AIRLOOP F2 N2 MAIN BRANCH | 0.194951 |
AIRLOOP F2 S1 MAIN BRANCH | 0.207052 |
AIRLOOP F2 S2 MAIN BRANCH | 0.208798 |
AIRLOOP F3 SW MAIN BRANCH | 0.357064 |
AIRLOOP F3 NW MAIN BRANCH | 0.353034 |
AIRLOOP F3 SE MAIN BRANCH | 0.308211 |
AIRLOOP F3 NE MAIN BRANCH | 0.290016 |
AIRLOOP F3 N1 MAIN BRANCH | 0.197810 |
AIRLOOP F3 N2 MAIN BRANCH | 0.196945 |
AIRLOOP F3 S1 MAIN BRANCH | 0.209441 |
AIRLOOP F3 S2 MAIN BRANCH | 0.210212 |
AIRLOOP F4 SW MAIN BRANCH | 0.358276 |
AIRLOOP F4 NW MAIN BRANCH | 0.354141 |
AIRLOOP F4 SE MAIN BRANCH | 0.308207 |
AIRLOOP F4 NE MAIN BRANCH | 0.291535 |
AIRLOOP F4 N1 MAIN BRANCH | 0.199845 |
AIRLOOP F4 N2 MAIN BRANCH | 0.198995 |
AIRLOOP F4 S1 MAIN BRANCH | 0.211446 |
AIRLOOP F4 S2 MAIN BRANCH | 0.212074 |
AIRLOOP M SW MAIN BRANCH | 0.361971 |
AIRLOOP M NW MAIN BRANCH | 0.357856 |
AIRLOOP M SE MAIN BRANCH | 0.312053 |
AIRLOOP M NE MAIN BRANCH | 0.295504 |
AIRLOOP M N1 MAIN BRANCH | 0.204131 |
AIRLOOP M N2 MAIN BRANCH | 0.203294 |
AIRLOOP M S1 MAIN BRANCH | 0.215637 |
AIRLOOP M S2 MAIN BRANCH | 0.216242 |
AIRLOOP F6 SW MAIN BRANCH | 0.358915 |
AIRLOOP F6 NW MAIN BRANCH | 0.354634 |
AIRLOOP F6 SE MAIN BRANCH | 0.309392 |
AIRLOOP F6 NE MAIN BRANCH | 0.292596 |
AIRLOOP F6 N1 MAIN BRANCH | 0.201601 |
AIRLOOP F6 N2 MAIN BRANCH | 0.200778 |
AIRLOOP F6 S1 MAIN BRANCH | 0.213173 |
AIRLOOP F6 S2 MAIN BRANCH | 0.213773 |
AIRLOOP F7 SW MAIN BRANCH | 0.358318 |
AIRLOOP F7 NW MAIN BRANCH | 0.353977 |
AIRLOOP F7 SE MAIN BRANCH | 0.309113 |
AIRLOOP F7 NE MAIN BRANCH | 0.292178 |
AIRLOOP F7 N1 MAIN BRANCH | 0.201449 |
AIRLOOP F7 N2 MAIN BRANCH | 0.200638 |
AIRLOOP F7 S1 MAIN BRANCH | 0.212998 |
AIRLOOP F7 S2 MAIN BRANCH | 0.213595 |
AIRLOOP F8 SW MAIN BRANCH | 0.359271 |
AIRLOOP F8 NW MAIN BRANCH | 0.354876 |
AIRLOOP F8 SE MAIN BRANCH | 0.310304 |
AIRLOOP F8 NE MAIN BRANCH | 0.293227 |
AIRLOOP F8 N1 MAIN BRANCH | 0.202779 |
AIRLOOP F8 N2 MAIN BRANCH | 0.201980 |
AIRLOOP F8 S1 MAIN BRANCH | 0.214261 |
AIRLOOP F8 S2 MAIN BRANCH | 0.214857 |
AIRLOOP F9 SW MAIN BRANCH | 0.369403 |
AIRLOOP F9 NW MAIN BRANCH | 0.365061 |
AIRLOOP F9 SE MAIN BRANCH | 0.316799 |
AIRLOOP F9 NE MAIN BRANCH | 0.299036 |
AIRLOOP F9 N1 MAIN BRANCH | 0.212448 |
AIRLOOP F9 N2 MAIN BRANCH | 0.211654 |
AIRLOOP F9 S1 MAIN BRANCH | 0.221718 |
AIRLOOP F9 S2 MAIN BRANCH | 0.222303 |
AIRLOOP T SW MAIN BRANCH | 0.435450 |
AIRLOOP T NW MAIN BRANCH | 0.427665 |
AIRLOOP T SE MAIN BRANCH | 0.377450 |
AIRLOOP T NE MAIN BRANCH | 0.348745 |
AIRLOOP T N1 MAIN BRANCH | 0.257880 |
AIRLOOP T N2 MAIN BRANCH | 0.256570 |
AIRLOOP T S1 MAIN BRANCH | 0.288532 |
AIRLOOP T S2 MAIN BRANCH | 0.289089 |
Design Supply Air Flow Rate [m3/s] | |
AIRLOOP G SW | 0.308247 |
AIRLOOP G NW | 0.305369 |
AIRLOOP OFFICE | 0.369788 |
AIRLOOP G NE | 0.244620 |
AIRLOOP G N1 | 0.166075 |
AIRLOOP G N2 | 0.164931 |
AIRLOOP G S1 | 0.173846 |
AIRLOOP G S2 | 0.178861 |
AIRLOOP F2 SW | 0.357233 |
AIRLOOP F2 NW | 0.353052 |
AIRLOOP F2 SE | 0.323198 |
AIRLOOP F2 NE | 0.288049 |
AIRLOOP F2 N1 | 0.195840 |
AIRLOOP F2 N2 | 0.194951 |
AIRLOOP F2 S1 | 0.207052 |
AIRLOOP F2 S2 | 0.208798 |
AIRLOOP F3 SW | 0.357064 |
AIRLOOP F3 NW | 0.353034 |
AIRLOOP F3 SE | 0.308211 |
AIRLOOP F3 NE | 0.290016 |
AIRLOOP F3 N1 | 0.197810 |
AIRLOOP F3 N2 | 0.196945 |
AIRLOOP F3 S1 | 0.209441 |
AIRLOOP F3 S2 | 0.210212 |
AIRLOOP F4 SW | 0.358276 |
AIRLOOP F4 NW | 0.354141 |
AIRLOOP F4 SE | 0.308207 |
AIRLOOP F4 NE | 0.291535 |
AIRLOOP F4 N1 | 0.199845 |
AIRLOOP F4 N2 | 0.198995 |
AIRLOOP F4 S1 | 0.211446 |
AIRLOOP F4 S2 | 0.212074 |
AIRLOOP M SW | 0.361971 |
AIRLOOP M NW | 0.357856 |
AIRLOOP M SE | 0.312053 |
AIRLOOP M NE | 0.295504 |
AIRLOOP M N1 | 0.204131 |
AIRLOOP M N2 | 0.203294 |
AIRLOOP M S1 | 0.215637 |
AIRLOOP M S2 | 0.216242 |
AIRLOOP F6 SW | 0.358915 |
AIRLOOP F6 NW | 0.354634 |
AIRLOOP F6 SE | 0.309392 |
AIRLOOP F6 NE | 0.292596 |
AIRLOOP F6 N1 | 0.201601 |
AIRLOOP F6 N2 | 0.200778 |
AIRLOOP F6 S1 | 0.213173 |
AIRLOOP F6 S2 | 0.213773 |
AIRLOOP F7 SW | 0.358318 |
AIRLOOP F7 NW | 0.353977 |
AIRLOOP F7 SE | 0.309113 |
AIRLOOP F7 NE | 0.292178 |
AIRLOOP F7 N1 | 0.201449 |
AIRLOOP F7 N2 | 0.200638 |
AIRLOOP F7 S1 | 0.212998 |
AIRLOOP F7 S2 | 0.213595 |
AIRLOOP F8 SW | 0.359271 |
AIRLOOP F8 NW | 0.354876 |
AIRLOOP F8 SE | 0.310304 |
AIRLOOP F8 NE | 0.293227 |
AIRLOOP F8 N1 | 0.202779 |
AIRLOOP F8 N2 | 0.201980 |
AIRLOOP F8 S1 | 0.214261 |
AIRLOOP F8 S2 | 0.214857 |
AIRLOOP F9 SW | 0.369403 |
AIRLOOP F9 NW | 0.365061 |
AIRLOOP F9 SE | 0.316799 |
AIRLOOP F9 NE | 0.299036 |
AIRLOOP F9 N1 | 0.212448 |
AIRLOOP F9 N2 | 0.211654 |
AIRLOOP F9 S1 | 0.221718 |
AIRLOOP F9 S2 | 0.222303 |
AIRLOOP T SW | 0.435450 |
AIRLOOP T NW | 0.427665 |
AIRLOOP T SE | 0.377450 |
AIRLOOP T NE | 0.348745 |
AIRLOOP T N1 | 0.257880 |
AIRLOOP T N2 | 0.256570 |
AIRLOOP T S1 | 0.288532 |
AIRLOOP T S2 | 0.289089 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
AIRLOOP G SW OA CONTROLLER | 0.308247 | 0.025952 |
AIRLOOP G NW OA CONTROLLER | 0.305369 | 0.025952 |
AIRLOOP OFFICE OA CONTROLLER | 0.369788 | 0.038103 |
AIRLOOP G NE OA CONTROLLER | 0.244620 | 0.025952 |
AIRLOOP G N1 OA CONTROLLER | 0.166075 | 0.025952 |
AIRLOOP G N2 OA CONTROLLER | 0.164931 | 0.025952 |
AIRLOOP G S1 OA CONTROLLER | 0.173846 | 0.025952 |
AIRLOOP G S2 OA CONTROLLER | 0.178861 | 0.025952 |
AIRLOOP F2 SW OA CONTROLLER | 0.357233 | 0.025952 |
AIRLOOP F2 NW OA CONTROLLER | 0.353052 | 0.025952 |
AIRLOOP F2 SE OA CONTROLLER | 0.323198 | 0.025952 |
AIRLOOP F2 NE OA CONTROLLER | 0.288049 | 0.025952 |
AIRLOOP F2 N1 OA CONTROLLER | 0.195840 | 0.025952 |
AIRLOOP F2 N2 OA CONTROLLER | 0.194951 | 0.025952 |
AIRLOOP F2 S1 OA CONTROLLER | 0.207052 | 0.025952 |
AIRLOOP F2 S2 OA CONTROLLER | 0.208798 | 0.025952 |
AIRLOOP F3 SW OA CONTROLLER | 0.357064 | 0.025952 |
AIRLOOP F3 NW OA CONTROLLER | 0.353034 | 0.025952 |
AIRLOOP F3 SE OA CONTROLLER | 0.308211 | 0.025952 |
AIRLOOP F3 NE OA CONTROLLER | 0.290016 | 0.025952 |
AIRLOOP F3 N1 OA CONTROLLER | 0.197810 | 0.025952 |
AIRLOOP F3 N2 OA CONTROLLER | 0.196945 | 0.025952 |
AIRLOOP F3 S1 OA CONTROLLER | 0.209441 | 0.025952 |
AIRLOOP F3 S2 OA CONTROLLER | 0.210212 | 0.025952 |
AIRLOOP F4 SW OA CONTROLLER | 0.358276 | 0.025952 |
AIRLOOP F4 NW OA CONTROLLER | 0.354141 | 0.025952 |
AIRLOOP F4 SE OA CONTROLLER | 0.308207 | 0.025952 |
AIRLOOP F4 NE OA CONTROLLER | 0.291535 | 0.025952 |
AIRLOOP F4 N1 OA CONTROLLER | 0.199845 | 0.025952 |
AIRLOOP F4 N2 OA CONTROLLER | 0.198995 | 0.025952 |
AIRLOOP F4 S1 OA CONTROLLER | 0.211446 | 0.025952 |
AIRLOOP F4 S2 OA CONTROLLER | 0.212074 | 0.025952 |
AIRLOOP M SW OA CONTROLLER | 0.361971 | 0.025952 |
AIRLOOP M NW OA CONTROLLER | 0.357856 | 0.025952 |
AIRLOOP M SE OA CONTROLLER | 0.312053 | 0.025952 |
AIRLOOP M NE OA CONTROLLER | 0.295504 | 0.025952 |
AIRLOOP M N1 OA CONTROLLER | 0.204131 | 0.025952 |
AIRLOOP M N2 OA CONTROLLER | 0.203294 | 0.025952 |
AIRLOOP M S1 OA CONTROLLER | 0.215637 | 0.025952 |
AIRLOOP M S2 OA CONTROLLER | 0.216242 | 0.025952 |
AIRLOOP F6 SW OA CONTROLLER | 0.358915 | 0.025952 |
AIRLOOP F6 NW OA CONTROLLER | 0.354634 | 0.025952 |
AIRLOOP F6 SE OA CONTROLLER | 0.309392 | 0.025952 |
AIRLOOP F6 NE OA CONTROLLER | 0.292596 | 0.025952 |
AIRLOOP F6 N1 OA CONTROLLER | 0.201601 | 0.025952 |
AIRLOOP F6 N2 OA CONTROLLER | 0.200778 | 0.025952 |
AIRLOOP F6 S1 OA CONTROLLER | 0.213173 | 0.025952 |
AIRLOOP F6 S2 OA CONTROLLER | 0.213773 | 0.025952 |
AIRLOOP F7 SW OA CONTROLLER | 0.358318 | 0.025952 |
AIRLOOP F7 NW OA CONTROLLER | 0.353977 | 0.025952 |
AIRLOOP F7 SE OA CONTROLLER | 0.309113 | 0.025952 |
AIRLOOP F7 NE OA CONTROLLER | 0.292178 | 0.025952 |
AIRLOOP F7 N1 OA CONTROLLER | 0.201449 | 0.025952 |
AIRLOOP F7 N2 OA CONTROLLER | 0.200638 | 0.025952 |
AIRLOOP F7 S1 OA CONTROLLER | 0.212998 | 0.025952 |
AIRLOOP F7 S2 OA CONTROLLER | 0.213595 | 0.025952 |
AIRLOOP F8 SW OA CONTROLLER | 0.359271 | 0.025952 |
AIRLOOP F8 NW OA CONTROLLER | 0.354876 | 0.025952 |
AIRLOOP F8 SE OA CONTROLLER | 0.310304 | 0.025952 |
AIRLOOP F8 NE OA CONTROLLER | 0.293227 | 0.025952 |
AIRLOOP F8 N1 OA CONTROLLER | 0.202779 | 0.025952 |
AIRLOOP F8 N2 OA CONTROLLER | 0.201980 | 0.025952 |
AIRLOOP F8 S1 OA CONTROLLER | 0.214261 | 0.025952 |
AIRLOOP F8 S2 OA CONTROLLER | 0.214857 | 0.025952 |
AIRLOOP F9 SW OA CONTROLLER | 0.369403 | 0.025952 |
AIRLOOP F9 NW OA CONTROLLER | 0.365061 | 0.025952 |
AIRLOOP F9 SE OA CONTROLLER | 0.316799 | 0.025952 |
AIRLOOP F9 NE OA CONTROLLER | 0.299036 | 0.025952 |
AIRLOOP F9 N1 OA CONTROLLER | 0.212448 | 0.025952 |
AIRLOOP F9 N2 OA CONTROLLER | 0.211654 | 0.025952 |
AIRLOOP F9 S1 OA CONTROLLER | 0.221718 | 0.025952 |
AIRLOOP F9 S2 OA CONTROLLER | 0.222303 | 0.025952 |
AIRLOOP T SW OA CONTROLLER | 0.435450 | 0.025952 |
AIRLOOP T NW OA CONTROLLER | 0.427665 | 0.025952 |
AIRLOOP T SE OA CONTROLLER | 0.377450 | 0.025952 |
AIRLOOP T NE OA CONTROLLER | 0.348745 | 0.025952 |
AIRLOOP T N1 OA CONTROLLER | 0.257880 | 0.025952 |
AIRLOOP T N2 OA CONTROLLER | 0.256570 | 0.025952 |
AIRLOOP T S1 OA CONTROLLER | 0.288532 | 0.025952 |
AIRLOOP T S2 OA CONTROLLER | 0.289089 | 0.025952 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity [W] | Rated Sensible Cooling Capacity [W] | Rated Water Flow Rate [m3/s] | |
HEAT PUMP COOLING MODE AIRLOOP G SW | 0.308247 | 4243.04 | 2984.76 | 0.000093 |
HEAT PUMP COOLING MODE AIRLOOP G NW | 0.305369 | 4183.96 | 2946.65 | 0.000091 |
HEAT PUMP COOLING MODE AIRLOOP OFFICE | 0.369788 | 5085.53 | 3591.12 | 0.000111 |
HEAT PUMP COOLING MODE AIRLOOP G NE | 0.244620 | 3334.17 | 2363.95 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP G N1 | 0.166075 | 2349.11 | 1643.81 | 0.000051 |
HEAT PUMP COOLING MODE AIRLOOP G N2 | 0.164931 | 2334.02 | 1633.15 | 0.000051 |
HEAT PUMP COOLING MODE AIRLOOP G S1 | 0.173846 | 2535.29 | 1753.96 | 0.000055 |
HEAT PUMP COOLING MODE AIRLOOP G S2 | 0.178861 | 2601.05 | 1800.76 | 0.000057 |
HEAT PUMP COOLING MODE AIRLOOP F2 SW | 0.357233 | 4853.94 | 3430.15 | 0.000106 |
HEAT PUMP COOLING MODE AIRLOOP F2 NW | 0.353052 | 4784.33 | 3382.77 | 0.000105 |
HEAT PUMP COOLING MODE AIRLOOP F2 SE | 0.323198 | 4373.99 | 3101.35 | 0.000096 |
HEAT PUMP COOLING MODE AIRLOOP F2 NE | 0.288049 | 3891.60 | 2766.56 | 0.000085 |
HEAT PUMP COOLING MODE AIRLOOP F2 N1 | 0.195840 | 2730.89 | 1921.22 | 0.000060 |
HEAT PUMP COOLING MODE AIRLOOP F2 N2 | 0.194951 | 2719.23 | 1912.97 | 0.000059 |
HEAT PUMP COOLING MODE AIRLOOP F2 S1 | 0.207052 | 2956.60 | 2060.46 | 0.000065 |
HEAT PUMP COOLING MODE AIRLOOP F2 S2 | 0.208798 | 2979.47 | 2076.71 | 0.000065 |
HEAT PUMP COOLING MODE AIRLOOP F3 SW | 0.357064 | 4837.17 | 3425.54 | 0.000106 |
HEAT PUMP COOLING MODE AIRLOOP F3 NW | 0.353034 | 4769.50 | 3379.55 | 0.000104 |
HEAT PUMP COOLING MODE AIRLOOP F3 SE | 0.308211 | 4163.72 | 2959.75 | 0.000091 |
HEAT PUMP COOLING MODE AIRLOOP F3 NE | 0.290016 | 3903.00 | 2781.77 | 0.000085 |
HEAT PUMP COOLING MODE AIRLOOP F3 N1 | 0.197810 | 2748.34 | 1937.76 | 0.000060 |
HEAT PUMP COOLING MODE AIRLOOP F3 N2 | 0.196945 | 2736.99 | 1929.73 | 0.000060 |
HEAT PUMP COOLING MODE AIRLOOP F3 S1 | 0.209441 | 2979.61 | 2080.95 | 0.000065 |
HEAT PUMP COOLING MODE AIRLOOP F3 S2 | 0.210212 | 2989.72 | 2088.13 | 0.000065 |
HEAT PUMP COOLING MODE AIRLOOP F4 SW | 0.358276 | 4842.12 | 3434.47 | 0.000106 |
HEAT PUMP COOLING MODE AIRLOOP F4 NW | 0.354141 | 4774.99 | 3389.91 | 0.000104 |
HEAT PUMP COOLING MODE AIRLOOP F4 SE | 0.308207 | 4152.90 | 2957.48 | 0.000091 |
HEAT PUMP COOLING MODE AIRLOOP F4 NE | 0.291535 | 3912.13 | 2793.59 | 0.000085 |
HEAT PUMP COOLING MODE AIRLOOP F4 N1 | 0.199845 | 2768.72 | 1955.34 | 0.000060 |
HEAT PUMP COOLING MODE AIRLOOP F4 N2 | 0.198995 | 2757.58 | 1947.45 | 0.000060 |
HEAT PUMP COOLING MODE AIRLOOP F4 S1 | 0.211446 | 2999.64 | 2098.30 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP F4 S2 | 0.212074 | 3007.87 | 2104.14 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP M SW | 0.361971 | 4881.49 | 3466.77 | 0.000107 |
HEAT PUMP COOLING MODE AIRLOOP M NW | 0.357856 | 4814.58 | 3422.38 | 0.000105 |
HEAT PUMP COOLING MODE AIRLOOP M SE | 0.312053 | 4203.87 | 2995.16 | 0.000092 |
HEAT PUMP COOLING MODE AIRLOOP M NE | 0.295504 | 3955.20 | 2828.47 | 0.000086 |
HEAT PUMP COOLING MODE AIRLOOP M N1 | 0.204131 | 2819.79 | 1994.05 | 0.000062 |
HEAT PUMP COOLING MODE AIRLOOP M N2 | 0.203294 | 2808.82 | 1986.28 | 0.000061 |
HEAT PUMP COOLING MODE AIRLOOP M S1 | 0.215637 | 3049.35 | 2136.18 | 0.000067 |
HEAT PUMP COOLING MODE AIRLOOP M S2 | 0.216242 | 3057.28 | 2141.81 | 0.000067 |
HEAT PUMP COOLING MODE AIRLOOP F6 SW | 0.358915 | 4839.40 | 3439.66 | 0.000106 |
HEAT PUMP COOLING MODE AIRLOOP F6 NW | 0.354634 | 4764.82 | 3391.00 | 0.000104 |
HEAT PUMP COOLING MODE AIRLOOP F6 SE | 0.309392 | 4161.69 | 2969.01 | 0.000091 |
HEAT PUMP COOLING MODE AIRLOOP F6 NE | 0.292596 | 3909.83 | 2800.05 | 0.000085 |
HEAT PUMP COOLING MODE AIRLOOP F6 N1 | 0.201601 | 2782.20 | 1969.65 | 0.000061 |
HEAT PUMP COOLING MODE AIRLOOP F6 N2 | 0.200778 | 2771.44 | 1962.02 | 0.000061 |
HEAT PUMP COOLING MODE AIRLOOP F6 S1 | 0.213173 | 3012.82 | 2112.38 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP F6 S2 | 0.213773 | 3020.68 | 2117.96 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP F7 SW | 0.358318 | 4824.90 | 3432.74 | 0.000105 |
HEAT PUMP COOLING MODE AIRLOOP F7 NW | 0.353977 | 4749.51 | 3383.53 | 0.000104 |
HEAT PUMP COOLING MODE AIRLOOP F7 SE | 0.309113 | 4151.50 | 2965.08 | 0.000091 |
HEAT PUMP COOLING MODE AIRLOOP F7 NE | 0.292178 | 3897.85 | 2794.84 | 0.000085 |
HEAT PUMP COOLING MODE AIRLOOP F7 N1 | 0.201449 | 2776.35 | 1967.44 | 0.000061 |
HEAT PUMP COOLING MODE AIRLOOP F7 N2 | 0.200638 | 2765.74 | 1959.91 | 0.000060 |
HEAT PUMP COOLING MODE AIRLOOP F7 S1 | 0.212998 | 3006.73 | 2109.96 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP F7 S2 | 0.213595 | 3014.55 | 2115.52 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP F8 SW | 0.359271 | 4831.34 | 3440.30 | 0.000106 |
HEAT PUMP COOLING MODE AIRLOOP F8 NW | 0.354876 | 4755.22 | 3390.58 | 0.000104 |
HEAT PUMP COOLING MODE AIRLOOP F8 SE | 0.310304 | 4161.15 | 2974.86 | 0.000091 |
HEAT PUMP COOLING MODE AIRLOOP F8 NE | 0.293227 | 3905.68 | 2803.33 | 0.000085 |
HEAT PUMP COOLING MODE AIRLOOP F8 N1 | 0.202779 | 2790.32 | 1979.06 | 0.000061 |
HEAT PUMP COOLING MODE AIRLOOP F8 N2 | 0.201980 | 2779.86 | 1971.65 | 0.000061 |
HEAT PUMP COOLING MODE AIRLOOP F8 S1 | 0.214261 | 3019.82 | 2120.99 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP F8 S2 | 0.214857 | 3027.62 | 2126.53 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP F9 SW | 0.369403 | 4952.70 | 3530.07 | 0.000108 |
HEAT PUMP COOLING MODE AIRLOOP F9 NW | 0.365061 | 4882.70 | 3483.55 | 0.000107 |
HEAT PUMP COOLING MODE AIRLOOP F9 SE | 0.316799 | 4240.41 | 3033.76 | 0.000093 |
HEAT PUMP COOLING MODE AIRLOOP F9 NE | 0.299036 | 3975.99 | 2855.89 | 0.000087 |
HEAT PUMP COOLING MODE AIRLOOP F9 N1 | 0.212448 | 2913.73 | 2068.07 | 0.000064 |
HEAT PUMP COOLING MODE AIRLOOP F9 N2 | 0.211654 | 2903.36 | 2060.72 | 0.000063 |
HEAT PUMP COOLING MODE AIRLOOP F9 S1 | 0.221718 | 3118.74 | 2191.44 | 0.000068 |
HEAT PUMP COOLING MODE AIRLOOP F9 S2 | 0.222303 | 3126.40 | 2196.88 | 0.000068 |
HEAT PUMP COOLING MODE AIRLOOP T SW | 0.435450 | 5820.94 | 4144.76 | 0.000127 |
HEAT PUMP COOLING MODE AIRLOOP T NW | 0.427665 | 5708.25 | 4067.27 | 0.000125 |
HEAT PUMP COOLING MODE AIRLOOP T SE | 0.377450 | 5093.90 | 3621.54 | 0.000111 |
HEAT PUMP COOLING MODE AIRLOOP T NE | 0.348745 | 4642.57 | 3323.94 | 0.000101 |
HEAT PUMP COOLING MODE AIRLOOP T N1 | 0.257880 | 3515.81 | 2493.40 | 0.000077 |
HEAT PUMP COOLING MODE AIRLOOP T N2 | 0.256570 | 3565.58 | 2512.02 | 0.000078 |
HEAT PUMP COOLING MODE AIRLOOP T S1 | 0.288532 | 3988.37 | 2810.42 | 0.000087 |
HEAT PUMP COOLING MODE AIRLOOP T S2 | 0.289089 | 3995.68 | 2815.59 | 0.000087 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Supplemental Heating Coil Nominal Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
AIRLOOP G SW DXAC HEAT PUMP | 0.308247 | 0.308247 | 0.308247 | 0.308247 | 4243.04 | 4243.04 | 2082.56 | 1.00 |
AIRLOOP G NW DXAC HEAT PUMP | 0.305369 | 0.305369 | 0.305369 | 0.305369 | 4183.96 | 4183.96 | 2093.15 | 1.00 |
AIRLOOP OFFICE DXAC HEAT PUMP | 0.369788 | 0.369788 | 0.369788 | 0.369788 | 5085.53 | 5085.53 | 2763.96 | 1.00 |
AIRLOOP G NE DXAC HEAT PUMP | 0.244620 | 0.244620 | 0.244620 | 0.244620 | 3334.17 | 3334.17 | 2087.42 | 1.00 |
AIRLOOP G N1 DXAC HEAT PUMP | 0.166075 | 0.166075 | 0.166075 | 0.166075 | 2349.11 | 2349.11 | 1491.36 | 1.00 |
AIRLOOP G N2 DXAC HEAT PUMP | 0.164931 | 0.164931 | 0.164931 | 0.164931 | 2334.02 | 2334.02 | 1491.27 | 1.00 |
AIRLOOP G S1 DXAC HEAT PUMP | 0.173846 | 0.173846 | 0.173846 | 0.173846 | 2535.29 | 2535.29 | 1478.41 | 1.00 |
AIRLOOP G S2 DXAC HEAT PUMP | 0.178861 | 0.178861 | 0.178861 | 0.178861 | 2601.05 | 2601.05 | 1486.73 | 1.00 |
AIRLOOP F2 SW DXAC HEAT PUMP | 0.357233 | 0.357233 | 0.357233 | 0.357233 | 4853.94 | 4853.94 | 2009.86 | 1.00 |
AIRLOOP F2 NW DXAC HEAT PUMP | 0.353052 | 0.353052 | 0.353052 | 0.353052 | 4784.33 | 4784.33 | 2019.31 | 1.00 |
AIRLOOP F2 SE DXAC HEAT PUMP | 0.323198 | 0.323198 | 0.323198 | 0.323198 | 4373.99 | 4373.99 | 2030.18 | 1.00 |
AIRLOOP F2 NE DXAC HEAT PUMP | 0.288049 | 0.288049 | 0.288049 | 0.288049 | 3891.60 | 3891.60 | 2013.51 | 1.00 |
AIRLOOP F2 N1 DXAC HEAT PUMP | 0.195840 | 0.195840 | 0.195840 | 0.195840 | 2730.89 | 2730.89 | 1314.37 | 1.00 |
AIRLOOP F2 N2 DXAC HEAT PUMP | 0.194951 | 0.194951 | 0.194951 | 0.194951 | 2719.23 | 2719.23 | 1314.27 | 1.00 |
AIRLOOP F2 S1 DXAC HEAT PUMP | 0.207052 | 0.207052 | 0.207052 | 0.207052 | 2956.60 | 2956.60 | 1307.62 | 1.00 |
AIRLOOP F2 S2 DXAC HEAT PUMP | 0.208798 | 0.208798 | 0.208798 | 0.208798 | 2979.47 | 2979.47 | 1309.38 | 1.00 |
AIRLOOP F3 SW DXAC HEAT PUMP | 0.357064 | 0.357064 | 0.357064 | 0.357064 | 4837.17 | 4837.17 | 1978.95 | 1.00 |
AIRLOOP F3 NW DXAC HEAT PUMP | 0.353034 | 0.353034 | 0.353034 | 0.353034 | 4769.50 | 4769.50 | 1987.31 | 1.00 |
AIRLOOP F3 SE DXAC HEAT PUMP | 0.308211 | 0.308211 | 0.308211 | 0.308211 | 4163.72 | 4163.72 | 1977.14 | 1.00 |
AIRLOOP F3 NE DXAC HEAT PUMP | 0.290016 | 0.290016 | 0.290016 | 0.290016 | 3903.00 | 3903.00 | 1982.33 | 1.00 |
AIRLOOP F3 N1 DXAC HEAT PUMP | 0.197810 | 0.197810 | 0.197810 | 0.197810 | 2748.34 | 2748.34 | 1267.10 | 1.00 |
AIRLOOP F3 N2 DXAC HEAT PUMP | 0.196945 | 0.196945 | 0.196945 | 0.196945 | 2736.99 | 2736.99 | 1267.01 | 1.00 |
AIRLOOP F3 S1 DXAC HEAT PUMP | 0.209441 | 0.209441 | 0.209441 | 0.209441 | 2979.61 | 2979.61 | 1259.30 | 1.00 |
AIRLOOP F3 S2 DXAC HEAT PUMP | 0.210212 | 0.210212 | 0.210212 | 0.210212 | 2989.72 | 2989.72 | 1259.53 | 1.00 |
AIRLOOP F4 SW DXAC HEAT PUMP | 0.358276 | 0.358276 | 0.358276 | 0.358276 | 4842.12 | 4842.12 | 1987.64 | 1.00 |
AIRLOOP F4 NW DXAC HEAT PUMP | 0.354141 | 0.354141 | 0.354141 | 0.354141 | 4774.99 | 4774.99 | 1995.13 | 1.00 |
AIRLOOP F4 SE DXAC HEAT PUMP | 0.308207 | 0.308207 | 0.308207 | 0.308207 | 4152.90 | 4152.90 | 1983.84 | 1.00 |
AIRLOOP F4 NE DXAC HEAT PUMP | 0.291535 | 0.291535 | 0.291535 | 0.291535 | 3912.13 | 3912.13 | 1990.96 | 1.00 |
AIRLOOP F4 N1 DXAC HEAT PUMP | 0.199845 | 0.199845 | 0.199845 | 0.199845 | 2768.72 | 2768.72 | 1262.23 | 1.00 |
AIRLOOP F4 N2 DXAC HEAT PUMP | 0.198995 | 0.198995 | 0.198995 | 0.198995 | 2757.58 | 2757.58 | 1262.15 | 1.00 |
AIRLOOP F4 S1 DXAC HEAT PUMP | 0.211446 | 0.211446 | 0.211446 | 0.211446 | 2999.64 | 2999.64 | 1255.00 | 1.00 |
AIRLOOP F4 S2 DXAC HEAT PUMP | 0.212074 | 0.212074 | 0.212074 | 0.212074 | 3007.87 | 3007.87 | 1254.98 | 1.00 |
AIRLOOP M SW DXAC HEAT PUMP | 0.361971 | 0.361971 | 0.361971 | 0.361971 | 4881.49 | 4881.49 | 1979.49 | 1.00 |
AIRLOOP M NW DXAC HEAT PUMP | 0.357856 | 0.357856 | 0.357856 | 0.357856 | 4814.58 | 4814.58 | 1984.83 | 1.00 |
AIRLOOP M SE DXAC HEAT PUMP | 0.312053 | 0.312053 | 0.312053 | 0.312053 | 4203.87 | 4203.87 | 1976.14 | 1.00 |
AIRLOOP M NE DXAC HEAT PUMP | 0.295504 | 0.295504 | 0.295504 | 0.295504 | 3955.20 | 3955.20 | 1981.43 | 1.00 |
AIRLOOP M N1 DXAC HEAT PUMP | 0.204131 | 0.204131 | 0.204131 | 0.204131 | 2819.79 | 2819.79 | 1245.13 | 1.00 |
AIRLOOP M N2 DXAC HEAT PUMP | 0.203294 | 0.203294 | 0.203294 | 0.203294 | 2808.82 | 2808.82 | 1245.07 | 1.00 |
AIRLOOP M S1 DXAC HEAT PUMP | 0.215637 | 0.215637 | 0.215637 | 0.215637 | 3049.35 | 3049.35 | 1240.02 | 1.00 |
AIRLOOP M S2 DXAC HEAT PUMP | 0.216242 | 0.216242 | 0.216242 | 0.216242 | 3057.28 | 3057.28 | 1239.97 | 1.00 |
AIRLOOP F6 SW DXAC HEAT PUMP | 0.358915 | 0.358915 | 0.358915 | 0.358915 | 4839.40 | 4839.40 | 2038.34 | 1.00 |
AIRLOOP F6 NW DXAC HEAT PUMP | 0.354634 | 0.354634 | 0.354634 | 0.354634 | 4764.82 | 4764.82 | 2043.54 | 1.00 |
AIRLOOP F6 SE DXAC HEAT PUMP | 0.309392 | 0.309392 | 0.309392 | 0.309392 | 4161.69 | 4161.69 | 2035.65 | 1.00 |
AIRLOOP F6 NE DXAC HEAT PUMP | 0.292596 | 0.292596 | 0.292596 | 0.292596 | 3909.83 | 3909.83 | 2040.85 | 1.00 |
AIRLOOP F6 N1 DXAC HEAT PUMP | 0.201601 | 0.201601 | 0.201601 | 0.201601 | 2782.20 | 2782.20 | 1291.38 | 1.00 |
AIRLOOP F6 N2 DXAC HEAT PUMP | 0.200778 | 0.200778 | 0.200778 | 0.200778 | 2771.44 | 2771.44 | 1291.33 | 1.00 |
AIRLOOP F6 S1 DXAC HEAT PUMP | 0.213173 | 0.213173 | 0.213173 | 0.213173 | 3012.82 | 3012.82 | 1286.37 | 1.00 |
AIRLOOP F6 S2 DXAC HEAT PUMP | 0.213773 | 0.213773 | 0.213773 | 0.213773 | 3020.68 | 3020.68 | 1286.32 | 1.00 |
AIRLOOP F7 SW DXAC HEAT PUMP | 0.358318 | 0.358318 | 0.358318 | 0.358318 | 4824.90 | 4824.90 | 2073.15 | 1.00 |
AIRLOOP F7 NW DXAC HEAT PUMP | 0.353977 | 0.353977 | 0.353977 | 0.353977 | 4749.51 | 4749.51 | 2077.09 | 1.00 |
AIRLOOP F7 SE DXAC HEAT PUMP | 0.309113 | 0.309113 | 0.309113 | 0.309113 | 4151.50 | 4151.50 | 2071.11 | 1.00 |
AIRLOOP F7 NE DXAC HEAT PUMP | 0.292178 | 0.292178 | 0.292178 | 0.292178 | 3897.85 | 3897.85 | 2075.05 | 1.00 |
AIRLOOP F7 N1 DXAC HEAT PUMP | 0.201449 | 0.201449 | 0.201449 | 0.201449 | 2776.35 | 2776.35 | 1317.05 | 1.00 |
AIRLOOP F7 N2 DXAC HEAT PUMP | 0.200638 | 0.200638 | 0.200638 | 0.200638 | 2765.74 | 2765.74 | 1317.01 | 1.00 |
AIRLOOP F7 S1 DXAC HEAT PUMP | 0.212998 | 0.212998 | 0.212998 | 0.212998 | 3006.73 | 3006.73 | 1313.28 | 1.00 |
AIRLOOP F7 S2 DXAC HEAT PUMP | 0.213595 | 0.213595 | 0.213595 | 0.213595 | 3014.55 | 3014.55 | 1313.24 | 1.00 |
AIRLOOP F8 SW DXAC HEAT PUMP | 0.359271 | 0.359271 | 0.359271 | 0.359271 | 4831.34 | 4831.34 | 2110.78 | 1.00 |
AIRLOOP F8 NW DXAC HEAT PUMP | 0.354876 | 0.354876 | 0.354876 | 0.354876 | 4755.22 | 4755.22 | 2113.39 | 1.00 |
AIRLOOP F8 SE DXAC HEAT PUMP | 0.310304 | 0.310304 | 0.310304 | 0.310304 | 4161.15 | 4161.15 | 2109.35 | 1.00 |
AIRLOOP F8 NE DXAC HEAT PUMP | 0.293227 | 0.293227 | 0.293227 | 0.293227 | 3905.68 | 3905.68 | 2111.96 | 1.00 |
AIRLOOP F8 N1 DXAC HEAT PUMP | 0.202779 | 0.202779 | 0.202779 | 0.202779 | 2790.32 | 2790.32 | 1346.83 | 1.00 |
AIRLOOP F8 N2 DXAC HEAT PUMP | 0.201980 | 0.201980 | 0.201980 | 0.201980 | 2779.86 | 2779.86 | 1346.81 | 1.00 |
AIRLOOP F8 S1 DXAC HEAT PUMP | 0.214261 | 0.214261 | 0.214261 | 0.214261 | 3019.82 | 3019.82 | 1344.40 | 1.00 |
AIRLOOP F8 S2 DXAC HEAT PUMP | 0.214857 | 0.214857 | 0.214857 | 0.214857 | 3027.62 | 3027.62 | 1344.37 | 1.00 |
AIRLOOP F9 SW DXAC HEAT PUMP | 0.369403 | 0.369403 | 0.369403 | 0.369403 | 4952.70 | 4952.70 | 2240.53 | 1.00 |
AIRLOOP F9 NW DXAC HEAT PUMP | 0.365061 | 0.365061 | 0.365061 | 0.365061 | 4882.70 | 4882.70 | 2240.16 | 1.00 |
AIRLOOP F9 SE DXAC HEAT PUMP | 0.316799 | 0.316799 | 0.316799 | 0.316799 | 4240.41 | 4240.41 | 2239.67 | 1.00 |
AIRLOOP F9 NE DXAC HEAT PUMP | 0.299036 | 0.299036 | 0.299036 | 0.299036 | 3975.99 | 3975.99 | 2239.30 | 1.00 |
AIRLOOP F9 N1 DXAC HEAT PUMP | 0.212448 | 0.212448 | 0.212448 | 0.212448 | 2913.73 | 2913.73 | 1460.96 | 1.00 |
AIRLOOP F9 N2 DXAC HEAT PUMP | 0.211654 | 0.211654 | 0.211654 | 0.211654 | 2903.36 | 2903.36 | 1460.95 | 1.00 |
AIRLOOP F9 S1 DXAC HEAT PUMP | 0.221718 | 0.221718 | 0.221718 | 0.221718 | 3118.74 | 3118.74 | 1461.26 | 1.00 |
AIRLOOP F9 S2 DXAC HEAT PUMP | 0.222303 | 0.222303 | 0.222303 | 0.222303 | 3126.40 | 3126.40 | 1461.25 | 1.00 |
AIRLOOP T SW DXAC HEAT PUMP | 0.435450 | 0.435450 | 0.435450 | 0.435450 | 5820.94 | 5820.94 | 2692.67 | 1.00 |
AIRLOOP T NW DXAC HEAT PUMP | 0.427665 | 0.427665 | 0.427665 | 0.427665 | 5708.25 | 5708.25 | 2695.76 | 1.00 |
AIRLOOP T SE DXAC HEAT PUMP | 0.377450 | 0.377450 | 0.377450 | 0.377450 | 5093.90 | 5093.90 | 2692.34 | 1.00 |
AIRLOOP T NE DXAC HEAT PUMP | 0.348745 | 0.348745 | 0.348745 | 0.348745 | 4642.57 | 4642.57 | 2695.43 | 1.00 |
AIRLOOP T N1 DXAC HEAT PUMP | 0.257880 | 0.257880 | 0.257880 | 0.257880 | 3515.81 | 3515.81 | 1952.16 | 1.00 |
AIRLOOP T N2 DXAC HEAT PUMP | 0.256570 | 0.256570 | 0.256570 | 0.256570 | 3565.58 | 3565.58 | 1952.16 | 1.00 |
AIRLOOP T S1 DXAC HEAT PUMP | 0.288532 | 0.288532 | 0.288532 | 0.288532 | 3988.37 | 3988.37 | 1948.17 | 1.00 |
AIRLOOP T S2 DXAC HEAT PUMP | 0.289089 | 0.289089 | 0.289089 | 0.289089 | 3995.68 | 3995.68 | 1948.16 | 1.00 |
Maximum Flow Rate [m3/s] | |
AIRLOOP G SW SUPPLY FAN | 0.308247 |
AIRLOOP G NW SUPPLY FAN | 0.305369 |
AIRLOOP OFFICE SUPPLY FAN | 0.369788 |
AIRLOOP G NE SUPPLY FAN | 0.244620 |
AIRLOOP G N1 SUPPLY FAN | 0.166075 |
AIRLOOP G N2 SUPPLY FAN | 0.164931 |
AIRLOOP G S1 SUPPLY FAN | 0.173846 |
AIRLOOP G S2 SUPPLY FAN | 0.178861 |
AIRLOOP F2 SW SUPPLY FAN | 0.357233 |
AIRLOOP F2 NW SUPPLY FAN | 0.353052 |
AIRLOOP F2 SE SUPPLY FAN | 0.323198 |
AIRLOOP F2 NE SUPPLY FAN | 0.288049 |
AIRLOOP F2 N1 SUPPLY FAN | 0.195840 |
AIRLOOP F2 N2 SUPPLY FAN | 0.194951 |
AIRLOOP F2 S1 SUPPLY FAN | 0.207052 |
AIRLOOP F2 S2 SUPPLY FAN | 0.208798 |
AIRLOOP F3 SW SUPPLY FAN | 0.357064 |
AIRLOOP F3 NW SUPPLY FAN | 0.353034 |
AIRLOOP F3 SE SUPPLY FAN | 0.308211 |
AIRLOOP F3 NE SUPPLY FAN | 0.290016 |
AIRLOOP F3 N1 SUPPLY FAN | 0.197810 |
AIRLOOP F3 N2 SUPPLY FAN | 0.196945 |
AIRLOOP F3 S1 SUPPLY FAN | 0.209441 |
AIRLOOP F3 S2 SUPPLY FAN | 0.210212 |
AIRLOOP F4 SW SUPPLY FAN | 0.358276 |
AIRLOOP F4 NW SUPPLY FAN | 0.354141 |
AIRLOOP F4 SE SUPPLY FAN | 0.308207 |
AIRLOOP F4 NE SUPPLY FAN | 0.291535 |
AIRLOOP F4 N1 SUPPLY FAN | 0.199845 |
AIRLOOP F4 N2 SUPPLY FAN | 0.198995 |
AIRLOOP F4 S1 SUPPLY FAN | 0.211446 |
AIRLOOP F4 S2 SUPPLY FAN | 0.212074 |
AIRLOOP M SW SUPPLY FAN | 0.361971 |
AIRLOOP M NW SUPPLY FAN | 0.357856 |
AIRLOOP M SE SUPPLY FAN | 0.312053 |
AIRLOOP M NE SUPPLY FAN | 0.295504 |
AIRLOOP M N1 SUPPLY FAN | 0.204131 |
AIRLOOP M N2 SUPPLY FAN | 0.203294 |
AIRLOOP M S1 SUPPLY FAN | 0.215637 |
AIRLOOP M S2 SUPPLY FAN | 0.216242 |
AIRLOOP F6 SW SUPPLY FAN | 0.358915 |
AIRLOOP F6 NW SUPPLY FAN | 0.354634 |
AIRLOOP F6 SE SUPPLY FAN | 0.309392 |
AIRLOOP F6 NE SUPPLY FAN | 0.292596 |
AIRLOOP F6 N1 SUPPLY FAN | 0.201601 |
AIRLOOP F6 N2 SUPPLY FAN | 0.200778 |
AIRLOOP F6 S1 SUPPLY FAN | 0.213173 |
AIRLOOP F6 S2 SUPPLY FAN | 0.213773 |
AIRLOOP F7 SW SUPPLY FAN | 0.358318 |
AIRLOOP F7 NW SUPPLY FAN | 0.353977 |
AIRLOOP F7 SE SUPPLY FAN | 0.309113 |
AIRLOOP F7 NE SUPPLY FAN | 0.292178 |
AIRLOOP F7 N1 SUPPLY FAN | 0.201449 |
AIRLOOP F7 N2 SUPPLY FAN | 0.200638 |
AIRLOOP F7 S1 SUPPLY FAN | 0.212998 |
AIRLOOP F7 S2 SUPPLY FAN | 0.213595 |
AIRLOOP F8 SW SUPPLY FAN | 0.359271 |
AIRLOOP F8 NW SUPPLY FAN | 0.354876 |
AIRLOOP F8 SE SUPPLY FAN | 0.310304 |
AIRLOOP F8 NE SUPPLY FAN | 0.293227 |
AIRLOOP F8 N1 SUPPLY FAN | 0.202779 |
AIRLOOP F8 N2 SUPPLY FAN | 0.201980 |
AIRLOOP F8 S1 SUPPLY FAN | 0.214261 |
AIRLOOP F8 S2 SUPPLY FAN | 0.214857 |
AIRLOOP F9 SW SUPPLY FAN | 0.369403 |
AIRLOOP F9 NW SUPPLY FAN | 0.365061 |
AIRLOOP F9 SE SUPPLY FAN | 0.316799 |
AIRLOOP F9 NE SUPPLY FAN | 0.299036 |
AIRLOOP F9 N1 SUPPLY FAN | 0.212448 |
AIRLOOP F9 N2 SUPPLY FAN | 0.211654 |
AIRLOOP F9 S1 SUPPLY FAN | 0.221718 |
AIRLOOP F9 S2 SUPPLY FAN | 0.222303 |
AIRLOOP T SW SUPPLY FAN | 0.435450 |
AIRLOOP T NW SUPPLY FAN | 0.427665 |
AIRLOOP T SE SUPPLY FAN | 0.377450 |
AIRLOOP T NE SUPPLY FAN | 0.348745 |
AIRLOOP T N1 SUPPLY FAN | 0.257880 |
AIRLOOP T N2 SUPPLY FAN | 0.256570 |
AIRLOOP T S1 SUPPLY FAN | 0.288532 |
AIRLOOP T S2 SUPPLY FAN | 0.289089 |
Rated Air Flow Rate [m3/s] | Rated Heating Capacity [W] | Rated Water Flow Rate [m3/s] | |
HEAT PUMP HEATING MODE AIRLOOP G SW | 0.308247 | 4243.04 | 0.000093 |
HEAT PUMP HEATING MODE AIRLOOP G NW | 0.305369 | 4183.96 | 0.000091 |
HEAT PUMP HEATING MODE AIRLOOP OFFICE | 0.369788 | 5085.53 | 0.000111 |
HEAT PUMP HEATING MODE AIRLOOP G NE | 0.244620 | 3334.17 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP G N1 | 0.166075 | 2349.11 | 0.000051 |
HEAT PUMP HEATING MODE AIRLOOP G N2 | 0.164931 | 2334.02 | 0.000051 |
HEAT PUMP HEATING MODE AIRLOOP G S1 | 0.173846 | 2535.29 | 0.000055 |
HEAT PUMP HEATING MODE AIRLOOP G S2 | 0.178861 | 2601.05 | 0.000057 |
HEAT PUMP HEATING MODE AIRLOOP F2 SW | 0.357233 | 4853.94 | 0.000106 |
HEAT PUMP HEATING MODE AIRLOOP F2 NW | 0.353052 | 4784.33 | 0.000105 |
HEAT PUMP HEATING MODE AIRLOOP F2 SE | 0.323198 | 4373.99 | 0.000096 |
HEAT PUMP HEATING MODE AIRLOOP F2 NE | 0.288049 | 3891.60 | 0.000085 |
HEAT PUMP HEATING MODE AIRLOOP F2 N1 | 0.195840 | 2730.89 | 0.000060 |
HEAT PUMP HEATING MODE AIRLOOP F2 N2 | 0.194951 | 2719.23 | 0.000059 |
HEAT PUMP HEATING MODE AIRLOOP F2 S1 | 0.207052 | 2956.60 | 0.000065 |
HEAT PUMP HEATING MODE AIRLOOP F2 S2 | 0.208798 | 2979.47 | 0.000065 |
HEAT PUMP HEATING MODE AIRLOOP F3 SW | 0.357064 | 4837.17 | 0.000106 |
HEAT PUMP HEATING MODE AIRLOOP F3 NW | 0.353034 | 4769.50 | 0.000104 |
HEAT PUMP HEATING MODE AIRLOOP F3 SE | 0.308211 | 4163.72 | 0.000091 |
HEAT PUMP HEATING MODE AIRLOOP F3 NE | 0.290016 | 3903.00 | 0.000085 |
HEAT PUMP HEATING MODE AIRLOOP F3 N1 | 0.197810 | 2748.34 | 0.000060 |
HEAT PUMP HEATING MODE AIRLOOP F3 N2 | 0.196945 | 2736.99 | 0.000060 |
HEAT PUMP HEATING MODE AIRLOOP F3 S1 | 0.209441 | 2979.61 | 0.000065 |
HEAT PUMP HEATING MODE AIRLOOP F3 S2 | 0.210212 | 2989.72 | 0.000065 |
HEAT PUMP HEATING MODE AIRLOOP F4 SW | 0.358276 | 4842.12 | 0.000106 |
HEAT PUMP HEATING MODE AIRLOOP F4 NW | 0.354141 | 4774.99 | 0.000104 |
HEAT PUMP HEATING MODE AIRLOOP F4 SE | 0.308207 | 4152.90 | 0.000091 |
HEAT PUMP HEATING MODE AIRLOOP F4 NE | 0.291535 | 3912.13 | 0.000085 |
HEAT PUMP HEATING MODE AIRLOOP F4 N1 | 0.199845 | 2768.72 | 0.000060 |
HEAT PUMP HEATING MODE AIRLOOP F4 N2 | 0.198995 | 2757.58 | 0.000060 |
HEAT PUMP HEATING MODE AIRLOOP F4 S1 | 0.211446 | 2999.64 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP F4 S2 | 0.212074 | 3007.87 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP M SW | 0.361971 | 4881.49 | 0.000107 |
HEAT PUMP HEATING MODE AIRLOOP M NW | 0.357856 | 4814.58 | 0.000105 |
HEAT PUMP HEATING MODE AIRLOOP M SE | 0.312053 | 4203.87 | 0.000092 |
HEAT PUMP HEATING MODE AIRLOOP M NE | 0.295504 | 3955.20 | 0.000086 |
HEAT PUMP HEATING MODE AIRLOOP M N1 | 0.204131 | 2819.79 | 0.000062 |
HEAT PUMP HEATING MODE AIRLOOP M N2 | 0.203294 | 2808.82 | 0.000061 |
HEAT PUMP HEATING MODE AIRLOOP M S1 | 0.215637 | 3049.35 | 0.000067 |
HEAT PUMP HEATING MODE AIRLOOP M S2 | 0.216242 | 3057.28 | 0.000067 |
HEAT PUMP HEATING MODE AIRLOOP F6 SW | 0.358915 | 4839.40 | 0.000106 |
HEAT PUMP HEATING MODE AIRLOOP F6 NW | 0.354634 | 4764.82 | 0.000104 |
HEAT PUMP HEATING MODE AIRLOOP F6 SE | 0.309392 | 4161.69 | 0.000091 |
HEAT PUMP HEATING MODE AIRLOOP F6 NE | 0.292596 | 3909.83 | 0.000085 |
HEAT PUMP HEATING MODE AIRLOOP F6 N1 | 0.201601 | 2782.20 | 0.000061 |
HEAT PUMP HEATING MODE AIRLOOP F6 N2 | 0.200778 | 2771.44 | 0.000061 |
HEAT PUMP HEATING MODE AIRLOOP F6 S1 | 0.213173 | 3012.82 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP F6 S2 | 0.213773 | 3020.68 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP F7 SW | 0.358318 | 4824.90 | 0.000105 |
HEAT PUMP HEATING MODE AIRLOOP F7 NW | 0.353977 | 4749.51 | 0.000104 |
HEAT PUMP HEATING MODE AIRLOOP F7 SE | 0.309113 | 4151.50 | 0.000091 |
HEAT PUMP HEATING MODE AIRLOOP F7 NE | 0.292178 | 3897.85 | 0.000085 |
HEAT PUMP HEATING MODE AIRLOOP F7 N1 | 0.201449 | 2776.35 | 0.000061 |
HEAT PUMP HEATING MODE AIRLOOP F7 N2 | 0.200638 | 2765.74 | 0.000060 |
HEAT PUMP HEATING MODE AIRLOOP F7 S1 | 0.212998 | 3006.73 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP F7 S2 | 0.213595 | 3014.55 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP F8 SW | 0.359271 | 4831.34 | 0.000106 |
HEAT PUMP HEATING MODE AIRLOOP F8 NW | 0.354876 | 4755.22 | 0.000104 |
HEAT PUMP HEATING MODE AIRLOOP F8 SE | 0.310304 | 4161.15 | 0.000091 |
HEAT PUMP HEATING MODE AIRLOOP F8 NE | 0.293227 | 3905.68 | 0.000085 |
HEAT PUMP HEATING MODE AIRLOOP F8 N1 | 0.202779 | 2790.32 | 0.000061 |
HEAT PUMP HEATING MODE AIRLOOP F8 N2 | 0.201980 | 2779.86 | 0.000061 |
HEAT PUMP HEATING MODE AIRLOOP F8 S1 | 0.214261 | 3019.82 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP F8 S2 | 0.214857 | 3027.62 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP F9 SW | 0.369403 | 4952.70 | 0.000108 |
HEAT PUMP HEATING MODE AIRLOOP F9 NW | 0.365061 | 4882.70 | 0.000107 |
HEAT PUMP HEATING MODE AIRLOOP F9 SE | 0.316799 | 4240.41 | 0.000093 |
HEAT PUMP HEATING MODE AIRLOOP F9 NE | 0.299036 | 3975.99 | 0.000087 |
HEAT PUMP HEATING MODE AIRLOOP F9 N1 | 0.212448 | 2913.73 | 0.000064 |
HEAT PUMP HEATING MODE AIRLOOP F9 N2 | 0.211654 | 2903.36 | 0.000063 |
HEAT PUMP HEATING MODE AIRLOOP F9 S1 | 0.221718 | 3118.74 | 0.000068 |
HEAT PUMP HEATING MODE AIRLOOP F9 S2 | 0.222303 | 3126.40 | 0.000068 |
HEAT PUMP HEATING MODE AIRLOOP T SW | 0.435450 | 5820.94 | 0.000127 |
HEAT PUMP HEATING MODE AIRLOOP T NW | 0.427665 | 5708.25 | 0.000125 |
HEAT PUMP HEATING MODE AIRLOOP T SE | 0.377450 | 5093.90 | 0.000111 |
HEAT PUMP HEATING MODE AIRLOOP T NE | 0.348745 | 4642.57 | 0.000101 |
HEAT PUMP HEATING MODE AIRLOOP T N1 | 0.257880 | 3515.81 | 0.000077 |
HEAT PUMP HEATING MODE AIRLOOP T N2 | 0.256570 | 3565.58 | 0.000078 |
HEAT PUMP HEATING MODE AIRLOOP T S1 | 0.288532 | 3988.37 | 0.000087 |
HEAT PUMP HEATING MODE AIRLOOP T S2 | 0.289089 | 3995.68 | 0.000087 |
Nominal Capacity [W] | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW | 2082.56 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW | 2093.15 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE | 2763.96 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE | 2087.42 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 | 1491.36 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 | 1491.27 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 | 1478.41 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 | 1486.73 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW | 2009.86 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW | 2019.31 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE | 2030.18 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE | 2013.51 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 | 1314.37 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 | 1314.27 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 | 1307.62 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 | 1309.38 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW | 1978.95 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW | 1987.31 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE | 1977.14 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE | 1982.33 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 | 1267.10 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 | 1267.01 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 | 1259.30 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 | 1259.53 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW | 1987.64 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW | 1995.13 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE | 1983.84 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE | 1990.96 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 | 1262.23 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 | 1262.15 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 | 1255.00 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 | 1254.98 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW | 1979.49 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW | 1984.83 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE | 1976.14 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE | 1981.43 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 | 1245.13 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 | 1245.07 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 | 1240.02 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 | 1239.97 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW | 2038.34 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW | 2043.54 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE | 2035.65 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE | 2040.85 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 | 1291.38 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 | 1291.33 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 | 1286.37 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 | 1286.32 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW | 2073.15 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW | 2077.09 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE | 2071.11 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE | 2075.05 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 | 1317.05 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 | 1317.01 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 | 1313.28 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 | 1313.24 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW | 2110.78 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW | 2113.39 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE | 2109.35 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE | 2111.96 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 | 1346.83 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 | 1346.81 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 | 1344.40 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 | 1344.37 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW | 2240.53 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW | 2240.16 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE | 2239.67 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE | 2239.30 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 | 1460.96 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 | 1460.95 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 | 1461.26 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 | 1461.25 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW | 2692.67 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW | 2695.76 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE | 2692.34 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE | 2695.43 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 | 1952.16 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 | 1952.16 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 | 1948.17 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 | 1948.16 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
SHWSYS1 | 0.000289 | 0.325214 |
SINGLE WATER PLANT LOOP | 0.006511 | 7.32 |
Design Water Flow Rate [m3/s] | |
CENTRAL BOILER | 0.006511 |
Use Side Design Flow Rate [m3/s] | |
SHWSYS1 WATER HEATER | 0.000289 |
Design Water Flow Rate [m3/s] | Fan Power at Design Air Flow Rate [W] | Design Air Flow Rate [m3/s] | U-Factor Times Area Value at Design Air Flow Rate [W/C] | |
CENTRAL TOWER | 0.006511 | 3143.11 | 9.11 | 8847.69 |
Rated Flow Rate [m3/s] | Rated Power Consumption [W] | |
SHWSYS1 PUMP | 0.000289 | 36.93 |
PLANT CIRC PUMP | 0.006511 | 1660.62 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:11
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW3 | |
G WWALL SWA | GWINDOW2 | |
G NWALL NWA | GWINDOW4 | |
G WWALL NWA | GWINDOW6 | |
G SWALL SEA | GWINDOW1 | |
G EWALL SEA | GWINDOW8 | |
G NWALL NEA | GWINDOW5 | |
G EWALL NEA | GWINDOW7 | |
G NWALL N1A | GWINDOW9 | |
G NWALL N2A | GWINDOW10 | |
G SWALL S1A | GWINDOW11 | |
G SWALL S2A | GWINDOW12 | |
G WWALL C | GWINDOW13 | |
G EWALL C | ENTRANCE DOOR | |
F2 WWALL SWA | F2WINDOW2 | |
F2 SWALL SWA | F2WINDOW3 | |
F2 NWALL NWA | F2WINDOW4 | |
F2 WWALL NWA | F2WINDOW6 | |
F2 EWALL SEA | F2WINDOW8 | |
F2 SWALL SEA | F2WINDOW1 | |
F2 NWALL NEA | F2WINDOW5 | |
F2 EWALL NEA | F2WINDOW7 | |
F2 NWALL N1A | F2WINDOW9 | |
F2 NWALL N2A | F2WINDOW10 | |
F2 SWALL S1A | F2WINDOW11 | |
F2 SWALL S2A | F2WINDOW12 | |
F2 WWALL C | F2WINDOW13 | |
F2 EWALL C | F2WINDOW14 | |
F3 WWALL SWA | F3WINDOW2 | |
F3 SWALL SWA | F3WINDOW3 | |
F3 NWALL NWA | F3WINDOW4 | |
F3 WWALL NWA | F3WINDOW6 | |
F3 EWALL SEA | F3WINDOW8 | |
F3 SWALL SEA | F3WINDOW1 | |
F3 NWALL NEA | F3WINDOW5 | |
F3 EWALL NEA | F3WINDOW7 | |
F3 NWALL N1A | F3WINDOW9 | |
F3 NWALL N2A | F3WINDOW10 | |
F3 SWALL S1A | F3WINDOW11 | |
F3 SWALL S2A | F3WINDOW12 | |
F3 WWALL C | F3WINDOW13 | |
F3 EWALL C | F3WINDOW14 | |
F4 WWALL SWA | F4WINDOW2 | |
F4 SWALL SWA | F4WINDOW3 | |
F4 NWALL NWA | F4WINDOW4 | |
F4 WWALL NWA | F4WINDOW6 | |
F4 EWALL SEA | F4WINDOW8 | |
F4 SWALL SEA | F4WINDOW1 | |
F4 NWALL NEA | F4WINDOW5 | |
F4 EWALL NEA | F4WINDOW7 | |
F4 NWALL N1A | F4WINDOW9 | |
F4 NWALL N2A | F4WINDOW10 | |
F4 SWALL S1A | F4WINDOW11 | |
F4 SWALL S2A | F4WINDOW12 | |
F4 WWALL C | F4WINDOW13 | |
F4 EWALL C | F4WINDOW14 | |
M WWALL SWA | MWINDOW2 | |
M SWALL SWA | MWINDOW3 | |
M NWALL NWA | MWINDOW4 | |
M WWALL NWA | MWINDOW6 | |
M EWALL SEA | MWINDOW8 | |
M SWALL SEA | MWINDOW1 | |
M NWALL NEA | MWINDOW5 | |
M EWALL NEA | MWINDOW7 | |
M NWALL N1A | MWINDOW9 | |
M NWALL N2A | MWINDOW10 | |
M SWALL S1A | MWINDOW11 | |
M SWALL S2A | MWINDOW12 | |
M WWALL C | MWINDOW13 | |
M EWALL C | MWINDOW14 | |
F6 WWALL SWA | F6WINDOW2 | |
F6 SWALL SWA | F6WINDOW3 | |
F6 NWALL NWA | F6WINDOW4 | |
F6 WWALL NWA | F6WINDOW6 | |
F6 EWALL SEA | F6WINDOW8 | |
F6 SWALL SEA | F6WINDOW1 | |
F6 NWALL NEA | F6WINDOW5 | |
F6 EWALL NEA | F6WINDOW7 | |
F6 NWALL N1A | F6WINDOW9 | |
F6 NWALL N2A | F6WINDOW10 | |
F6 SWALL S1A | F6WINDOW11 | |
F6 SWALL S2A | F6WINDOW12 | |
F6 WWALL C | F6WINDOW13 | |
F6 EWALL C | F6WINDOW14 | |
F7 WWALL SWA | F7WINDOW2 | |
F7 SWALL SWA | F7WINDOW3 | |
F7 NWALL NWA | F7WINDOW4 | |
F7 WWALL NWA | F7WINDOW6 | |
F7 EWALL SEA | F7WINDOW8 | |
F7 SWALL SEA | F7WINDOW1 | |
F7 NWALL NEA | F7WINDOW5 | |
F7 EWALL NEA | F7WINDOW7 | |
F7 NWALL N1A | F7WINDOW9 | |
F7 NWALL N2A | F7WINDOW10 | |
F7 SWALL S1A | F7WINDOW11 | |
F7 SWALL S2A | F7WINDOW12 | |
F7 WWALL C | F7WINDOW13 | |
F7 EWALL C | F7WINDOW14 | |
F8 WWALL SWA | F8WINDOW2 | |
F8 SWALL SWA | F8WINDOW3 | |
F8 NWALL NWA | F8WINDOW4 | |
F8 WWALL NWA | F8WINDOW6 | |
F8 EWALL SEA | F8WINDOW8 | |
F8 SWALL SEA | F8WINDOW1 | |
F8 NWALL NEA | F8WINDOW5 | |
F8 EWALL NEA | F8WINDOW7 | |
F8 NWALL N1A | F8WINDOW9 | |
F8 NWALL N2A | F8WINDOW10 | |
F8 SWALL S1A | F8WINDOW11 | |
F8 SWALL S2A | F8WINDOW12 | |
F8 WWALL C | F8WINDOW13 | |
F8 EWALL C | F8WINDOW14 | |
F9 WWALL SWA | F9WINDOW2 | |
F9 SWALL SWA | F9WINDOW3 | |
F9 NWALL NWA | F9WINDOW4 | |
F9 WWALL NWA | F9WINDOW6 | |
F9 EWALL SEA | F9WINDOW8 | |
F9 SWALL SEA | F9WINDOW1 | |
F9 NWALL NEA | F9WINDOW5 | |
F9 EWALL NEA | F9WINDOW7 | |
F9 NWALL N1A | F9WINDOW9 | |
F9 NWALL N2A | F9WINDOW10 | |
F9 SWALL S1A | F9WINDOW11 | |
F9 SWALL S2A | F9WINDOW12 | |
F9 WWALL C | F9WINDOW13 | |
F9 EWALL C | F9WINDOW14 | |
T WWALL SWA | TWINDOW2 | |
T SWALL SWA | TWINDOW3 | |
T NWALL NWA | TWINDOW4 | |
T WWALL NWA | TWINDOW6 | |
T EWALL SEA | TWINDOW8 | |
T SWALL SEA | TWINDOW1 | |
T NWALL NEA | TWINDOW5 | |
T EWALL NEA | TWINDOW7 | |
T NWALL N1A | TWINDOW9 | |
T NWALL N2A | TWINDOW10 | |
T SWALL S1A | TWINDOW11 | |
T SWALL S2A | TWINDOW12 | |
T WWALL C | TWINDOW13 | |
T EWALL C | TWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2018-10-19 09:40:11
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.53 | 14.83 |
February | 23.16 | 12.72 |
March | 23.38 | 15.42 |
April | 24.19 | 23.31 |
May | 24.32 | 26.31 |
June | 24.42 | 31.20 |
July | 24.40 | 30.42 |
August | 24.41 | 29.82 |
September | 24.40 | 27.75 |
October | 24.07 | 20.87 |
November | 23.59 | 15.43 |
December | 23.20 | 11.86 |
Annual Sum or Average | 23.93 | 21.71 |
Minimum of Months | 23.16 | 11.86 |
Maximum of Months | 24.42 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.85 | 14.83 |
February | 22.49 | 12.72 |
March | 23.03 | 15.42 |
April | 24.16 | 23.31 |
May | 24.34 | 26.31 |
June | 24.44 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.39 | 27.75 |
October | 23.86 | 20.87 |
November | 23.01 | 15.43 |
December | 22.40 | 11.86 |
Annual Sum or Average | 23.65 | 21.71 |
Minimum of Months | 22.40 | 11.86 |
Maximum of Months | 24.44 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.46 | 14.83 |
February | 23.12 | 12.72 |
March | 23.50 | 15.42 |
April | 24.26 | 23.31 |
May | 24.37 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.41 | 29.82 |
September | 24.41 | 27.75 |
October | 24.10 | 20.87 |
November | 23.60 | 15.43 |
December | 23.13 | 11.86 |
Annual Sum or Average | 23.93 | 21.71 |
Minimum of Months | 23.12 | 11.86 |
Maximum of Months | 24.41 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.83 | 14.83 |
February | 22.45 | 12.72 |
March | 23.03 | 15.42 |
April | 24.18 | 23.31 |
May | 24.34 | 26.31 |
June | 24.41 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.39 | 27.75 |
October | 23.87 | 20.87 |
November | 22.93 | 15.43 |
December | 22.35 | 11.86 |
Annual Sum or Average | 23.64 | 21.71 |
Minimum of Months | 22.35 | 11.86 |
Maximum of Months | 24.41 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.65 | 14.83 |
February | 22.28 | 12.72 |
March | 22.82 | 15.42 |
April | 24.10 | 23.31 |
May | 24.31 | 26.31 |
June | 24.44 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.39 | 27.75 |
October | 23.78 | 20.87 |
November | 22.79 | 15.43 |
December | 22.22 | 11.86 |
Annual Sum or Average | 23.56 | 21.71 |
Minimum of Months | 22.22 | 11.86 |
Maximum of Months | 24.44 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.65 | 14.83 |
February | 22.28 | 12.72 |
March | 22.82 | 15.42 |
April | 24.09 | 23.31 |
May | 24.31 | 26.31 |
June | 24.44 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.39 | 27.75 |
October | 23.78 | 20.87 |
November | 22.78 | 15.43 |
December | 22.22 | 11.86 |
Annual Sum or Average | 23.55 | 21.71 |
Minimum of Months | 22.22 | 11.86 |
Maximum of Months | 24.44 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.64 | 14.83 |
February | 23.20 | 12.72 |
March | 23.36 | 15.42 |
April | 24.16 | 23.31 |
May | 24.31 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.43 | 29.82 |
September | 24.48 | 27.75 |
October | 24.12 | 20.87 |
November | 23.64 | 15.43 |
December | 23.30 | 11.86 |
Annual Sum or Average | 23.96 | 21.71 |
Minimum of Months | 23.20 | 11.86 |
Maximum of Months | 24.48 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.65 | 14.83 |
February | 23.23 | 12.72 |
March | 23.38 | 15.42 |
April | 24.17 | 23.31 |
May | 24.31 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.43 | 29.82 |
September | 24.47 | 27.75 |
October | 24.13 | 20.87 |
November | 23.66 | 15.43 |
December | 23.31 | 11.86 |
Annual Sum or Average | 23.96 | 21.71 |
Minimum of Months | 23.23 | 11.86 |
Maximum of Months | 24.47 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.67 | 14.83 |
February | 20.52 | 12.72 |
March | 21.79 | 15.42 |
April | 24.97 | 23.31 |
May | 26.06 | 26.31 |
June | 28.13 | 31.20 |
July | 27.82 | 30.42 |
August | 27.61 | 29.82 |
September | 26.99 | 27.75 |
October | 24.09 | 20.87 |
November | 21.88 | 15.43 |
December | 20.51 | 11.86 |
Annual Sum or Average | 24.36 | 21.71 |
Minimum of Months | 20.51 | 11.86 |
Maximum of Months | 28.13 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F2 SW APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.13 | 14.83 |
February | 23.95 | 12.72 |
March | 23.99 | 15.42 |
April | 24.36 | 23.31 |
May | 24.38 | 26.31 |
June | 24.42 | 31.20 |
July | 24.40 | 30.42 |
August | 24.41 | 29.82 |
September | 24.41 | 27.75 |
October | 24.32 | 20.87 |
November | 24.14 | 15.43 |
December | 23.83 | 11.86 |
Annual Sum or Average | 24.23 | 21.71 |
Minimum of Months | 23.83 | 11.86 |
Maximum of Months | 24.42 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F2 NW APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.52 | 14.83 |
February | 23.28 | 12.72 |
March | 23.63 | 15.42 |
April | 24.34 | 23.31 |
May | 24.39 | 26.31 |
June | 24.44 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.16 | 20.87 |
November | 23.64 | 15.43 |
December | 22.92 | 11.86 |
Annual Sum or Average | 23.96 | 21.71 |
Minimum of Months | 22.92 | 11.86 |
Maximum of Months | 24.44 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F2 SE APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.12 | 14.83 |
February | 23.94 | 12.72 |
March | 24.02 | 15.42 |
April | 24.38 | 23.31 |
May | 24.39 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.42 | 27.75 |
October | 24.34 | 20.87 |
November | 24.12 | 15.43 |
December | 23.83 | 11.86 |
Annual Sum or Average | 24.23 | 21.71 |
Minimum of Months | 23.83 | 11.86 |
Maximum of Months | 24.42 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F2 NE APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.45 | 14.83 |
February | 23.18 | 12.72 |
March | 23.61 | 15.42 |
April | 24.35 | 23.31 |
May | 24.39 | 26.31 |
June | 24.42 | 31.20 |
July | 24.40 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.16 | 20.87 |
November | 23.52 | 15.43 |
December | 22.85 | 11.86 |
Annual Sum or Average | 23.93 | 21.71 |
Minimum of Months | 22.85 | 11.86 |
Maximum of Months | 24.42 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F2 N1 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.43 | 14.83 |
February | 23.16 | 12.72 |
March | 23.52 | 15.42 |
April | 24.32 | 23.31 |
May | 24.38 | 26.31 |
June | 24.44 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.13 | 20.87 |
November | 23.51 | 15.43 |
December | 22.82 | 11.86 |
Annual Sum or Average | 23.91 | 21.71 |
Minimum of Months | 22.82 | 11.86 |
Maximum of Months | 24.44 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F2 N2 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.42 | 14.83 |
February | 23.15 | 12.72 |
March | 23.52 | 15.42 |
April | 24.33 | 23.31 |
May | 24.38 | 26.31 |
June | 24.44 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.13 | 20.87 |
November | 23.50 | 15.43 |
December | 22.82 | 11.86 |
Annual Sum or Average | 23.91 | 21.71 |
Minimum of Months | 22.82 | 11.86 |
Maximum of Months | 24.44 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F2 S1 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.29 | 14.83 |
February | 24.04 | 12.72 |
March | 24.04 | 15.42 |
April | 24.35 | 23.31 |
May | 24.37 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.47 | 27.75 |
October | 24.41 | 20.87 |
November | 24.23 | 15.43 |
December | 24.02 | 11.86 |
Annual Sum or Average | 24.29 | 21.71 |
Minimum of Months | 24.02 | 11.86 |
Maximum of Months | 24.47 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F2 S2 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.29 | 14.83 |
February | 24.05 | 12.72 |
March | 24.05 | 15.42 |
April | 24.35 | 23.31 |
May | 24.37 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.47 | 27.75 |
October | 24.41 | 20.87 |
November | 24.23 | 15.43 |
December | 24.03 | 11.86 |
Annual Sum or Average | 24.29 | 21.71 |
Minimum of Months | 24.03 | 11.86 |
Maximum of Months | 24.47 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F2 CORRIDOR
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.92 | 14.83 |
February | 24.42 | 12.72 |
March | 24.87 | 15.42 |
April | 26.22 | 23.31 |
May | 26.51 | 26.31 |
June | 27.11 | 31.20 |
July | 26.97 | 30.42 |
August | 26.91 | 29.82 |
September | 26.74 | 27.75 |
October | 25.90 | 20.87 |
November | 25.02 | 15.43 |
December | 24.27 | 11.86 |
Annual Sum or Average | 25.83 | 21.71 |
Minimum of Months | 24.27 | 11.86 |
Maximum of Months | 27.11 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F3 SW APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.21 | 14.83 |
February | 24.08 | 12.72 |
March | 24.07 | 15.42 |
April | 24.36 | 23.31 |
May | 24.38 | 26.31 |
June | 24.42 | 31.20 |
July | 24.40 | 30.42 |
August | 24.41 | 29.82 |
September | 24.41 | 27.75 |
October | 24.34 | 20.87 |
November | 24.20 | 15.43 |
December | 23.94 | 11.86 |
Annual Sum or Average | 24.27 | 21.71 |
Minimum of Months | 23.94 | 11.86 |
Maximum of Months | 24.42 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F3 NW APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.67 | 14.83 |
February | 23.52 | 12.72 |
March | 23.75 | 15.42 |
April | 24.35 | 23.31 |
May | 24.39 | 26.31 |
June | 24.45 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.20 | 20.87 |
November | 23.77 | 15.43 |
December | 23.08 | 11.86 |
Annual Sum or Average | 24.03 | 21.71 |
Minimum of Months | 23.08 | 11.86 |
Maximum of Months | 24.45 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F3 SE APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.17 | 14.83 |
February | 24.03 | 12.72 |
March | 24.06 | 15.42 |
April | 24.38 | 23.31 |
May | 24.39 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.43 | 27.75 |
October | 24.36 | 20.87 |
November | 24.16 | 15.43 |
December | 23.90 | 11.86 |
Annual Sum or Average | 24.26 | 21.71 |
Minimum of Months | 23.90 | 11.86 |
Maximum of Months | 24.43 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F3 NE APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.60 | 14.83 |
February | 23.42 | 12.72 |
March | 23.73 | 15.42 |
April | 24.37 | 23.31 |
May | 24.39 | 26.31 |
June | 24.42 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.20 | 20.87 |
November | 23.67 | 15.43 |
December | 23.01 | 11.86 |
Annual Sum or Average | 24.00 | 21.71 |
Minimum of Months | 23.01 | 11.86 |
Maximum of Months | 24.42 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F3 N1 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.66 | 14.83 |
February | 23.50 | 12.72 |
March | 23.71 | 15.42 |
April | 24.34 | 23.31 |
May | 24.38 | 26.31 |
June | 24.45 | 31.20 |
July | 24.42 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.19 | 20.87 |
November | 23.71 | 15.43 |
December | 23.06 | 11.86 |
Annual Sum or Average | 24.02 | 21.71 |
Minimum of Months | 23.06 | 11.86 |
Maximum of Months | 24.45 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F3 N2 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.65 | 14.83 |
February | 23.49 | 12.72 |
March | 23.71 | 15.42 |
April | 24.34 | 23.31 |
May | 24.38 | 26.31 |
June | 24.45 | 31.20 |
July | 24.42 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.20 | 20.87 |
November | 23.70 | 15.43 |
December | 23.05 | 11.86 |
Annual Sum or Average | 24.02 | 21.71 |
Minimum of Months | 23.05 | 11.86 |
Maximum of Months | 24.45 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F3 S1 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.38 | 14.83 |
February | 24.19 | 12.72 |
March | 24.15 | 15.42 |
April | 24.36 | 23.31 |
May | 24.38 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.47 | 27.75 |
October | 24.44 | 20.87 |
November | 24.31 | 15.43 |
December | 24.16 | 11.86 |
Annual Sum or Average | 24.34 | 21.71 |
Minimum of Months | 24.15 | 11.86 |
Maximum of Months | 24.47 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F3 S2 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.38 | 14.83 |
February | 24.19 | 12.72 |
March | 24.15 | 15.42 |
April | 24.36 | 23.31 |
May | 24.38 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.47 | 27.75 |
October | 24.44 | 20.87 |
November | 24.31 | 15.43 |
December | 24.16 | 11.86 |
Annual Sum or Average | 24.34 | 21.71 |
Minimum of Months | 24.15 | 11.86 |
Maximum of Months | 24.47 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F3 CORRIDOR
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 25.40 | 14.83 |
February | 25.01 | 12.72 |
March | 25.33 | 15.42 |
April | 26.46 | 23.31 |
May | 26.67 | 26.31 |
June | 27.09 | 31.20 |
July | 26.96 | 30.42 |
August | 26.90 | 29.82 |
September | 26.76 | 27.75 |
October | 26.18 | 20.87 |
November | 25.47 | 15.43 |
December | 24.80 | 11.86 |
Annual Sum or Average | 26.09 | 21.71 |
Minimum of Months | 24.80 | 11.86 |
Maximum of Months | 27.09 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F4 SW APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.21 | 14.83 |
February | 24.10 | 12.72 |
March | 24.07 | 15.42 |
April | 24.36 | 23.31 |
May | 24.38 | 26.31 |
June | 24.42 | 31.20 |
July | 24.40 | 30.42 |
August | 24.41 | 29.82 |
September | 24.40 | 27.75 |
October | 24.34 | 20.87 |
November | 24.20 | 15.43 |
December | 23.96 | 11.86 |
Annual Sum or Average | 24.27 | 21.71 |
Minimum of Months | 23.96 | 11.86 |
Maximum of Months | 24.42 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F4 NW APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.70 | 14.83 |
February | 23.58 | 12.72 |
March | 23.76 | 15.42 |
April | 24.35 | 23.31 |
May | 24.39 | 26.31 |
June | 24.45 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.20 | 20.87 |
November | 23.79 | 15.43 |
December | 23.13 | 11.86 |
Annual Sum or Average | 24.05 | 21.71 |
Minimum of Months | 23.13 | 11.86 |
Maximum of Months | 24.45 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F4 SE APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.17 | 14.83 |
February | 24.04 | 12.72 |
March | 24.05 | 15.42 |
April | 24.38 | 23.31 |
May | 24.39 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.43 | 27.75 |
October | 24.36 | 20.87 |
November | 24.16 | 15.43 |
December | 23.91 | 11.86 |
Annual Sum or Average | 24.26 | 21.71 |
Minimum of Months | 23.91 | 11.86 |
Maximum of Months | 24.43 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F4 NE APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.63 | 14.83 |
February | 23.48 | 12.72 |
March | 23.75 | 15.42 |
April | 24.37 | 23.31 |
May | 24.39 | 26.31 |
June | 24.43 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.20 | 20.87 |
November | 23.69 | 15.43 |
December | 23.06 | 11.86 |
Annual Sum or Average | 24.02 | 21.71 |
Minimum of Months | 23.06 | 11.86 |
Maximum of Months | 24.43 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F4 N1 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.72 | 14.83 |
February | 23.60 | 12.72 |
March | 23.76 | 15.42 |
April | 24.34 | 23.31 |
May | 24.38 | 26.31 |
June | 24.45 | 31.20 |
July | 24.42 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.20 | 20.87 |
November | 23.76 | 15.43 |
December | 23.14 | 11.86 |
Annual Sum or Average | 24.05 | 21.71 |
Minimum of Months | 23.14 | 11.86 |
Maximum of Months | 24.45 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F4 N2 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.71 | 14.83 |
February | 23.60 | 12.72 |
March | 23.76 | 15.42 |
April | 24.34 | 23.31 |
May | 24.38 | 26.31 |
June | 24.45 | 31.20 |
July | 24.42 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.20 | 20.87 |
November | 23.75 | 15.43 |
December | 23.13 | 11.86 |
Annual Sum or Average | 24.05 | 21.71 |
Minimum of Months | 23.13 | 11.86 |
Maximum of Months | 24.45 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F4 S1 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.39 | 14.83 |
February | 24.22 | 12.72 |
March | 24.16 | 15.42 |
April | 24.36 | 23.31 |
May | 24.38 | 26.31 |
June | 24.41 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.46 | 27.75 |
October | 24.44 | 20.87 |
November | 24.32 | 15.43 |
December | 24.18 | 11.86 |
Annual Sum or Average | 24.35 | 21.71 |
Minimum of Months | 24.16 | 11.86 |
Maximum of Months | 24.46 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F4 S2 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.39 | 14.83 |
February | 24.22 | 12.72 |
March | 24.16 | 15.42 |
April | 24.36 | 23.31 |
May | 24.38 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.46 | 27.75 |
October | 24.44 | 20.87 |
November | 24.32 | 15.43 |
December | 24.18 | 11.86 |
Annual Sum or Average | 24.35 | 21.71 |
Minimum of Months | 24.16 | 11.86 |
Maximum of Months | 24.46 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F4 CORRIDOR
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 25.58 | 14.83 |
February | 25.23 | 12.72 |
March | 25.50 | 15.42 |
April | 26.58 | 23.31 |
May | 26.78 | 26.31 |
June | 27.17 | 31.20 |
July | 27.03 | 30.42 |
August | 26.97 | 29.82 |
September | 26.84 | 27.75 |
October | 26.30 | 20.87 |
November | 25.64 | 15.43 |
December | 25.00 | 11.86 |
Annual Sum or Average | 26.22 | 21.71 |
Minimum of Months | 25.00 | 11.86 |
Maximum of Months | 27.17 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.21 | 14.83 |
February | 24.11 | 12.72 |
March | 24.07 | 15.42 |
April | 24.36 | 23.31 |
May | 24.38 | 26.31 |
June | 24.43 | 31.20 |
July | 24.40 | 30.42 |
August | 24.41 | 29.82 |
September | 24.40 | 27.75 |
October | 24.34 | 20.87 |
November | 24.20 | 15.43 |
December | 23.97 | 11.86 |
Annual Sum or Average | 24.28 | 21.71 |
Minimum of Months | 23.97 | 11.86 |
Maximum of Months | 24.43 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.72 | 14.83 |
February | 23.60 | 12.72 |
March | 23.77 | 15.42 |
April | 24.35 | 23.31 |
May | 24.39 | 26.31 |
June | 24.45 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.20 | 20.87 |
November | 23.80 | 15.43 |
December | 23.16 | 11.86 |
Annual Sum or Average | 24.06 | 21.71 |
Minimum of Months | 23.16 | 11.86 |
Maximum of Months | 24.45 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.17 | 14.83 |
February | 24.05 | 12.72 |
March | 24.05 | 15.42 |
April | 24.38 | 23.31 |
May | 24.39 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.43 | 27.75 |
October | 24.35 | 20.87 |
November | 24.16 | 15.43 |
December | 23.92 | 11.86 |
Annual Sum or Average | 24.26 | 21.71 |
Minimum of Months | 23.92 | 11.86 |
Maximum of Months | 24.43 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.65 | 14.83 |
February | 23.51 | 12.72 |
March | 23.75 | 15.42 |
April | 24.37 | 23.31 |
May | 24.39 | 26.31 |
June | 24.43 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.20 | 20.87 |
November | 23.70 | 15.43 |
December | 23.09 | 11.86 |
Annual Sum or Average | 24.03 | 21.71 |
Minimum of Months | 23.09 | 11.86 |
Maximum of Months | 24.43 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.75 | 14.83 |
February | 23.66 | 12.72 |
March | 23.78 | 15.42 |
April | 24.35 | 23.31 |
May | 24.39 | 26.31 |
June | 24.45 | 31.20 |
July | 24.42 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.21 | 20.87 |
November | 23.79 | 15.43 |
December | 23.20 | 11.86 |
Annual Sum or Average | 24.07 | 21.71 |
Minimum of Months | 23.20 | 11.86 |
Maximum of Months | 24.45 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.74 | 14.83 |
February | 23.65 | 12.72 |
March | 23.78 | 15.42 |
April | 24.35 | 23.31 |
May | 24.39 | 26.31 |
June | 24.45 | 31.20 |
July | 24.42 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.21 | 20.87 |
November | 23.78 | 15.43 |
December | 23.19 | 11.86 |
Annual Sum or Average | 24.06 | 21.71 |
Minimum of Months | 23.19 | 11.86 |
Maximum of Months | 24.45 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.39 | 14.83 |
February | 24.23 | 12.72 |
March | 24.17 | 15.42 |
April | 24.36 | 23.31 |
May | 24.38 | 26.31 |
June | 24.41 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.46 | 27.75 |
October | 24.44 | 20.87 |
November | 24.32 | 15.43 |
December | 24.20 | 11.86 |
Annual Sum or Average | 24.35 | 21.71 |
Minimum of Months | 24.17 | 11.86 |
Maximum of Months | 24.46 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.39 | 14.83 |
February | 24.23 | 12.72 |
March | 24.17 | 15.42 |
April | 24.36 | 23.31 |
May | 24.38 | 26.31 |
June | 24.41 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.46 | 27.75 |
October | 24.44 | 20.87 |
November | 24.32 | 15.43 |
December | 24.20 | 11.86 |
Annual Sum or Average | 24.35 | 21.71 |
Minimum of Months | 24.17 | 11.86 |
Maximum of Months | 24.46 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.21 | 14.83 |
February | 25.87 | 12.72 |
March | 26.11 | 15.42 |
April | 27.17 | 23.31 |
May | 27.37 | 26.31 |
June | 27.75 | 31.20 |
July | 27.61 | 30.42 |
August | 27.55 | 29.82 |
September | 27.43 | 27.75 |
October | 26.90 | 20.87 |
November | 26.26 | 15.43 |
December | 25.65 | 11.86 |
Annual Sum or Average | 26.83 | 21.71 |
Minimum of Months | 25.65 | 11.86 |
Maximum of Months | 27.75 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F6 SW APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.17 | 14.83 |
February | 24.06 | 12.72 |
March | 24.02 | 15.42 |
April | 24.36 | 23.31 |
May | 24.38 | 26.31 |
June | 24.43 | 31.20 |
July | 24.40 | 30.42 |
August | 24.41 | 29.82 |
September | 24.40 | 27.75 |
October | 24.32 | 20.87 |
November | 24.17 | 15.43 |
December | 23.92 | 11.86 |
Annual Sum or Average | 24.25 | 21.71 |
Minimum of Months | 23.92 | 11.86 |
Maximum of Months | 24.43 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F6 NW APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.64 | 14.83 |
February | 23.49 | 12.72 |
March | 23.69 | 15.42 |
April | 24.35 | 23.31 |
May | 24.39 | 26.31 |
June | 24.45 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.17 | 20.87 |
November | 23.72 | 15.43 |
December | 23.07 | 11.86 |
Annual Sum or Average | 24.02 | 21.71 |
Minimum of Months | 23.07 | 11.86 |
Maximum of Months | 24.45 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F6 SE APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.13 | 14.83 |
February | 23.98 | 12.72 |
March | 24.00 | 15.42 |
April | 24.37 | 23.31 |
May | 24.39 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.43 | 27.75 |
October | 24.34 | 20.87 |
November | 24.12 | 15.43 |
December | 23.88 | 11.86 |
Annual Sum or Average | 24.24 | 21.71 |
Minimum of Months | 23.88 | 11.86 |
Maximum of Months | 24.43 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F6 NE APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.56 | 14.83 |
February | 23.39 | 12.72 |
March | 23.67 | 15.42 |
April | 24.36 | 23.31 |
May | 24.39 | 26.31 |
June | 24.44 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.17 | 20.87 |
November | 23.62 | 15.43 |
December | 23.00 | 11.86 |
Annual Sum or Average | 23.99 | 21.71 |
Minimum of Months | 23.00 | 11.86 |
Maximum of Months | 24.44 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F6 N1 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.67 | 14.83 |
February | 23.55 | 12.72 |
March | 23.69 | 15.42 |
April | 24.34 | 23.31 |
May | 24.38 | 26.31 |
June | 24.46 | 31.20 |
July | 24.42 | 30.42 |
August | 24.40 | 29.82 |
September | 24.39 | 27.75 |
October | 24.18 | 20.87 |
November | 23.71 | 15.43 |
December | 23.10 | 11.86 |
Annual Sum or Average | 24.03 | 21.71 |
Minimum of Months | 23.10 | 11.86 |
Maximum of Months | 24.46 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F6 N2 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.66 | 14.83 |
February | 23.54 | 12.72 |
March | 23.69 | 15.42 |
April | 24.34 | 23.31 |
May | 24.38 | 26.31 |
June | 24.46 | 31.20 |
July | 24.42 | 30.42 |
August | 24.40 | 29.82 |
September | 24.39 | 27.75 |
October | 24.18 | 20.87 |
November | 23.70 | 15.43 |
December | 23.10 | 11.86 |
Annual Sum or Average | 24.02 | 21.71 |
Minimum of Months | 23.10 | 11.86 |
Maximum of Months | 24.46 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F6 S1 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.36 | 14.83 |
February | 24.19 | 12.72 |
March | 24.12 | 15.42 |
April | 24.35 | 23.31 |
May | 24.37 | 26.31 |
June | 24.41 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.46 | 27.75 |
October | 24.42 | 20.87 |
November | 24.29 | 15.43 |
December | 24.16 | 11.86 |
Annual Sum or Average | 24.33 | 21.71 |
Minimum of Months | 24.12 | 11.86 |
Maximum of Months | 24.46 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F6 S2 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.36 | 14.83 |
February | 24.19 | 12.72 |
March | 24.12 | 15.42 |
April | 24.35 | 23.31 |
May | 24.37 | 26.31 |
June | 24.41 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.46 | 27.75 |
October | 24.42 | 20.87 |
November | 24.29 | 15.43 |
December | 24.16 | 11.86 |
Annual Sum or Average | 24.33 | 21.71 |
Minimum of Months | 24.12 | 11.86 |
Maximum of Months | 24.46 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F6 CORRIDOR
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 25.54 | 14.83 |
February | 25.18 | 12.72 |
March | 25.44 | 15.42 |
April | 26.56 | 23.31 |
May | 26.77 | 26.31 |
June | 27.17 | 31.20 |
July | 27.02 | 30.42 |
August | 26.96 | 29.82 |
September | 26.83 | 27.75 |
October | 26.27 | 20.87 |
November | 25.59 | 15.43 |
December | 24.97 | 11.86 |
Annual Sum or Average | 26.20 | 21.71 |
Minimum of Months | 24.97 | 11.86 |
Maximum of Months | 27.17 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F7 SW APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.15 | 14.83 |
February | 24.01 | 12.72 |
March | 23.98 | 15.42 |
April | 24.35 | 23.31 |
May | 24.38 | 26.31 |
June | 24.43 | 31.20 |
July | 24.40 | 30.42 |
August | 24.41 | 29.82 |
September | 24.40 | 27.75 |
October | 24.31 | 20.87 |
November | 24.14 | 15.43 |
December | 23.89 | 11.86 |
Annual Sum or Average | 24.24 | 21.71 |
Minimum of Months | 23.89 | 11.86 |
Maximum of Months | 24.43 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F7 NW APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.58 | 14.83 |
February | 23.39 | 12.72 |
March | 23.62 | 15.42 |
April | 24.34 | 23.31 |
May | 24.39 | 26.31 |
June | 24.45 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.14 | 20.87 |
November | 23.66 | 15.43 |
December | 23.01 | 11.86 |
Annual Sum or Average | 23.99 | 21.71 |
Minimum of Months | 23.01 | 11.86 |
Maximum of Months | 24.45 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F7 SE APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.10 | 14.83 |
February | 23.93 | 12.72 |
March | 23.96 | 15.42 |
April | 24.37 | 23.31 |
May | 24.38 | 26.31 |
June | 24.41 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.43 | 27.75 |
October | 24.32 | 20.87 |
November | 24.09 | 15.43 |
December | 23.84 | 11.86 |
Annual Sum or Average | 24.22 | 21.71 |
Minimum of Months | 23.84 | 11.86 |
Maximum of Months | 24.43 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F7 NE APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.50 | 14.83 |
February | 23.30 | 12.72 |
March | 23.61 | 15.42 |
April | 24.35 | 23.31 |
May | 24.39 | 26.31 |
June | 24.44 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.40 | 27.75 |
October | 24.15 | 20.87 |
November | 23.55 | 15.43 |
December | 22.94 | 11.86 |
Annual Sum or Average | 23.96 | 21.71 |
Minimum of Months | 22.94 | 11.86 |
Maximum of Months | 24.44 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F7 N1 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.61 | 14.83 |
February | 23.45 | 12.72 |
March | 23.63 | 15.42 |
April | 24.33 | 23.31 |
May | 24.38 | 26.31 |
June | 24.46 | 31.20 |
July | 24.42 | 30.42 |
August | 24.40 | 29.82 |
September | 24.39 | 27.75 |
October | 24.15 | 20.87 |
November | 23.65 | 15.43 |
December | 23.04 | 11.86 |
Annual Sum or Average | 23.99 | 21.71 |
Minimum of Months | 23.04 | 11.86 |
Maximum of Months | 24.46 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F7 N2 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.60 | 14.83 |
February | 23.45 | 12.72 |
March | 23.63 | 15.42 |
April | 24.33 | 23.31 |
May | 24.38 | 26.31 |
June | 24.46 | 31.20 |
July | 24.42 | 30.42 |
August | 24.40 | 29.82 |
September | 24.39 | 27.75 |
October | 24.15 | 20.87 |
November | 23.64 | 15.43 |
December | 23.03 | 11.86 |
Annual Sum or Average | 23.99 | 21.71 |
Minimum of Months | 23.03 | 11.86 |
Maximum of Months | 24.46 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F7 S1 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.34 | 14.83 |
February | 24.16 | 12.72 |
March | 24.09 | 15.42 |
April | 24.35 | 23.31 |
May | 24.37 | 26.31 |
June | 24.41 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.45 | 27.75 |
October | 24.40 | 20.87 |
November | 24.26 | 15.43 |
December | 24.13 | 11.86 |
Annual Sum or Average | 24.32 | 21.71 |
Minimum of Months | 24.09 | 11.86 |
Maximum of Months | 24.45 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F7 S2 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.34 | 14.83 |
February | 24.15 | 12.72 |
March | 24.09 | 15.42 |
April | 24.35 | 23.31 |
May | 24.37 | 26.31 |
June | 24.41 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.45 | 27.75 |
October | 24.40 | 20.87 |
November | 24.26 | 15.43 |
December | 24.13 | 11.86 |
Annual Sum or Average | 24.32 | 21.71 |
Minimum of Months | 24.09 | 11.86 |
Maximum of Months | 24.45 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F7 CORRIDOR
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 25.39 | 14.83 |
February | 25.01 | 12.72 |
March | 25.29 | 15.42 |
April | 26.47 | 23.31 |
May | 26.69 | 26.31 |
June | 27.09 | 31.20 |
July | 26.95 | 30.42 |
August | 26.89 | 29.82 |
September | 26.75 | 27.75 |
October | 26.15 | 20.87 |
November | 25.44 | 15.43 |
December | 24.82 | 11.86 |
Annual Sum or Average | 26.08 | 21.71 |
Minimum of Months | 24.82 | 11.86 |
Maximum of Months | 27.09 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F8 SW APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.12 | 14.83 |
February | 23.96 | 12.72 |
March | 23.94 | 15.42 |
April | 24.35 | 23.31 |
May | 24.38 | 26.31 |
June | 24.43 | 31.20 |
July | 24.40 | 30.42 |
August | 24.41 | 29.82 |
September | 24.40 | 27.75 |
October | 24.29 | 20.87 |
November | 24.11 | 15.43 |
December | 23.85 | 11.86 |
Annual Sum or Average | 24.22 | 21.71 |
Minimum of Months | 23.85 | 11.86 |
Maximum of Months | 24.43 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F8 NW APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.52 | 14.83 |
February | 23.31 | 12.72 |
March | 23.57 | 15.42 |
April | 24.34 | 23.31 |
May | 24.39 | 26.31 |
June | 24.46 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.39 | 27.75 |
October | 24.12 | 20.87 |
November | 23.61 | 15.43 |
December | 22.95 | 11.86 |
Annual Sum or Average | 23.96 | 21.71 |
Minimum of Months | 22.95 | 11.86 |
Maximum of Months | 24.46 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F8 SE APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.07 | 14.83 |
February | 23.88 | 12.72 |
March | 23.92 | 15.42 |
April | 24.36 | 23.31 |
May | 24.38 | 26.31 |
June | 24.41 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.43 | 27.75 |
October | 24.31 | 20.87 |
November | 24.06 | 15.43 |
December | 23.81 | 11.86 |
Annual Sum or Average | 24.21 | 21.71 |
Minimum of Months | 23.81 | 11.86 |
Maximum of Months | 24.43 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F8 NE APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.44 | 14.83 |
February | 23.22 | 12.72 |
March | 23.55 | 15.42 |
April | 24.35 | 23.31 |
May | 24.39 | 26.31 |
June | 24.44 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.39 | 27.75 |
October | 24.13 | 20.87 |
November | 23.50 | 15.43 |
December | 22.88 | 11.86 |
Annual Sum or Average | 23.93 | 21.71 |
Minimum of Months | 22.88 | 11.86 |
Maximum of Months | 24.44 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F8 N1 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.55 | 14.83 |
February | 23.36 | 12.72 |
March | 23.56 | 15.42 |
April | 24.33 | 23.31 |
May | 24.38 | 26.31 |
June | 24.46 | 31.20 |
July | 24.42 | 30.42 |
August | 24.40 | 29.82 |
September | 24.39 | 27.75 |
October | 24.13 | 20.87 |
November | 23.59 | 15.43 |
December | 22.97 | 11.86 |
Annual Sum or Average | 23.96 | 21.71 |
Minimum of Months | 22.97 | 11.86 |
Maximum of Months | 24.46 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F8 N2 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.54 | 14.83 |
February | 23.36 | 12.72 |
March | 23.56 | 15.42 |
April | 24.33 | 23.31 |
May | 24.38 | 26.31 |
June | 24.46 | 31.20 |
July | 24.42 | 30.42 |
August | 24.40 | 29.82 |
September | 24.39 | 27.75 |
October | 24.13 | 20.87 |
November | 23.58 | 15.43 |
December | 22.97 | 11.86 |
Annual Sum or Average | 23.96 | 21.71 |
Minimum of Months | 22.97 | 11.86 |
Maximum of Months | 24.46 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F8 S1 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.31 | 14.83 |
February | 24.12 | 12.72 |
March | 24.05 | 15.42 |
April | 24.34 | 23.31 |
May | 24.37 | 26.31 |
June | 24.41 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.45 | 27.75 |
October | 24.39 | 20.87 |
November | 24.24 | 15.43 |
December | 24.10 | 11.86 |
Annual Sum or Average | 24.30 | 21.71 |
Minimum of Months | 24.05 | 11.86 |
Maximum of Months | 24.45 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F8 S2 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.31 | 14.83 |
February | 24.12 | 12.72 |
March | 24.05 | 15.42 |
April | 24.35 | 23.31 |
May | 24.37 | 26.31 |
June | 24.41 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.45 | 27.75 |
October | 24.39 | 20.87 |
November | 24.24 | 15.43 |
December | 24.10 | 11.86 |
Annual Sum or Average | 24.30 | 21.71 |
Minimum of Months | 24.05 | 11.86 |
Maximum of Months | 24.45 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F8 CORRIDOR
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 25.30 | 14.83 |
February | 24.90 | 12.72 |
March | 25.20 | 15.42 |
April | 26.45 | 23.31 |
May | 26.68 | 26.31 |
June | 27.10 | 31.20 |
July | 26.96 | 30.42 |
August | 26.89 | 29.82 |
September | 26.75 | 27.75 |
October | 26.11 | 20.87 |
November | 25.36 | 15.43 |
December | 24.72 | 11.86 |
Annual Sum or Average | 26.04 | 21.71 |
Minimum of Months | 24.72 | 11.86 |
Maximum of Months | 27.10 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F9 SW APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.07 | 14.83 |
February | 23.88 | 12.72 |
March | 23.88 | 15.42 |
April | 24.34 | 23.31 |
May | 24.38 | 26.31 |
June | 24.43 | 31.20 |
July | 24.40 | 30.42 |
August | 24.41 | 29.82 |
September | 24.40 | 27.75 |
October | 24.27 | 20.87 |
November | 24.06 | 15.43 |
December | 23.78 | 11.86 |
Annual Sum or Average | 24.19 | 21.71 |
Minimum of Months | 23.78 | 11.86 |
Maximum of Months | 24.43 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F9 NW APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.44 | 14.83 |
February | 23.19 | 12.72 |
March | 23.50 | 15.42 |
April | 24.33 | 23.31 |
May | 24.39 | 26.31 |
June | 24.45 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.39 | 27.75 |
October | 24.08 | 20.87 |
November | 23.54 | 15.43 |
December | 22.87 | 11.86 |
Annual Sum or Average | 23.92 | 21.71 |
Minimum of Months | 22.87 | 11.86 |
Maximum of Months | 24.45 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F9 SE APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.02 | 14.83 |
February | 23.79 | 12.72 |
March | 23.86 | 15.42 |
April | 24.36 | 23.31 |
May | 24.38 | 26.31 |
June | 24.41 | 31.20 |
July | 24.40 | 30.42 |
August | 24.41 | 29.82 |
September | 24.42 | 27.75 |
October | 24.28 | 20.87 |
November | 24.01 | 15.43 |
December | 23.73 | 11.86 |
Annual Sum or Average | 24.18 | 21.71 |
Minimum of Months | 23.73 | 11.86 |
Maximum of Months | 24.42 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F9 NE APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.36 | 14.83 |
February | 23.11 | 12.72 |
March | 23.49 | 15.42 |
April | 24.35 | 23.31 |
May | 24.39 | 26.31 |
June | 24.45 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.39 | 27.75 |
October | 24.10 | 20.87 |
November | 23.42 | 15.43 |
December | 22.79 | 11.86 |
Annual Sum or Average | 23.89 | 21.71 |
Minimum of Months | 22.79 | 11.86 |
Maximum of Months | 24.45 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F9 N1 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.46 | 14.83 |
February | 23.23 | 12.72 |
March | 23.49 | 15.42 |
April | 24.32 | 23.31 |
May | 24.38 | 26.31 |
June | 24.46 | 31.20 |
July | 24.42 | 30.42 |
August | 24.40 | 29.82 |
September | 24.39 | 27.75 |
October | 24.09 | 20.87 |
November | 23.51 | 15.43 |
December | 22.87 | 11.86 |
Annual Sum or Average | 23.92 | 21.71 |
Minimum of Months | 22.87 | 11.86 |
Maximum of Months | 24.46 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F9 N2 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.45 | 14.83 |
February | 23.23 | 12.72 |
March | 23.49 | 15.42 |
April | 24.33 | 23.31 |
May | 24.38 | 26.31 |
June | 24.46 | 31.20 |
July | 24.42 | 30.42 |
August | 24.40 | 29.82 |
September | 24.39 | 27.75 |
October | 24.09 | 20.87 |
November | 23.50 | 15.43 |
December | 22.87 | 11.86 |
Annual Sum or Average | 23.92 | 21.71 |
Minimum of Months | 22.87 | 11.86 |
Maximum of Months | 24.46 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F9 S1 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.25 | 14.83 |
February | 24.04 | 12.72 |
March | 23.99 | 15.42 |
April | 24.34 | 23.31 |
May | 24.37 | 26.31 |
June | 24.41 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.44 | 27.75 |
October | 24.35 | 20.87 |
November | 24.19 | 15.43 |
December | 24.02 | 11.86 |
Annual Sum or Average | 24.27 | 21.71 |
Minimum of Months | 23.99 | 11.86 |
Maximum of Months | 24.44 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F9 S2 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.25 | 14.83 |
February | 24.04 | 12.72 |
March | 23.99 | 15.42 |
April | 24.34 | 23.31 |
May | 24.37 | 26.31 |
June | 24.41 | 31.20 |
July | 24.40 | 30.42 |
August | 24.42 | 29.82 |
September | 24.44 | 27.75 |
October | 24.35 | 20.87 |
November | 24.18 | 15.43 |
December | 24.02 | 11.86 |
Annual Sum or Average | 24.27 | 21.71 |
Minimum of Months | 23.99 | 11.86 |
Maximum of Months | 24.44 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: F9 CORRIDOR
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 25.17 | 14.83 |
February | 24.74 | 12.72 |
March | 25.10 | 15.42 |
April | 26.49 | 23.31 |
May | 26.76 | 26.31 |
June | 27.23 | 31.20 |
July | 27.08 | 30.42 |
August | 27.01 | 29.82 |
September | 26.84 | 27.75 |
October | 26.09 | 20.87 |
November | 25.24 | 15.43 |
December | 24.55 | 11.86 |
Annual Sum or Average | 26.03 | 21.71 |
Minimum of Months | 24.55 | 11.86 |
Maximum of Months | 27.23 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.63 | 14.83 |
February | 23.48 | 12.72 |
March | 23.57 | 15.42 |
April | 24.26 | 23.31 |
May | 24.35 | 26.31 |
June | 24.43 | 31.20 |
July | 24.40 | 30.42 |
August | 24.41 | 29.82 |
September | 24.40 | 27.75 |
October | 24.10 | 20.87 |
November | 23.71 | 15.43 |
December | 23.36 | 11.86 |
Annual Sum or Average | 24.01 | 21.71 |
Minimum of Months | 23.36 | 11.86 |
Maximum of Months | 24.43 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.15 | 14.83 |
February | 22.99 | 12.72 |
March | 23.30 | 15.42 |
April | 24.24 | 23.31 |
May | 24.36 | 26.31 |
June | 24.46 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.39 | 27.75 |
October | 23.91 | 20.87 |
November | 23.30 | 15.43 |
December | 22.75 | 11.86 |
Annual Sum or Average | 23.81 | 21.71 |
Minimum of Months | 22.75 | 11.86 |
Maximum of Months | 24.46 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.59 | 14.83 |
February | 23.41 | 12.72 |
March | 23.55 | 15.42 |
April | 24.28 | 23.31 |
May | 24.36 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.41 | 29.82 |
September | 24.41 | 27.75 |
October | 24.10 | 20.87 |
November | 23.66 | 15.43 |
December | 23.33 | 11.86 |
Annual Sum or Average | 24.00 | 21.71 |
Minimum of Months | 23.33 | 11.86 |
Maximum of Months | 24.41 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.12 | 14.83 |
February | 22.91 | 12.72 |
March | 23.30 | 15.42 |
April | 24.26 | 23.31 |
May | 24.36 | 26.31 |
June | 24.45 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.39 | 27.75 |
October | 23.93 | 20.87 |
November | 23.20 | 15.43 |
December | 22.70 | 11.86 |
Annual Sum or Average | 23.79 | 21.71 |
Minimum of Months | 22.70 | 11.86 |
Maximum of Months | 24.45 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.14 | 14.83 |
February | 22.96 | 12.72 |
March | 23.27 | 15.42 |
April | 24.24 | 23.31 |
May | 24.36 | 26.31 |
June | 24.47 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.39 | 27.75 |
October | 23.92 | 20.87 |
November | 23.24 | 15.43 |
December | 22.68 | 11.86 |
Annual Sum or Average | 23.79 | 21.71 |
Minimum of Months | 22.68 | 11.86 |
Maximum of Months | 24.47 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.13 | 14.83 |
February | 22.96 | 12.72 |
March | 23.27 | 15.42 |
April | 24.24 | 23.31 |
May | 24.36 | 26.31 |
June | 24.46 | 31.20 |
July | 24.41 | 30.42 |
August | 24.40 | 29.82 |
September | 24.39 | 27.75 |
October | 23.92 | 20.87 |
November | 23.23 | 15.43 |
December | 22.67 | 11.86 |
Annual Sum or Average | 23.79 | 21.71 |
Minimum of Months | 22.67 | 11.86 |
Maximum of Months | 24.46 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.84 | 14.83 |
February | 23.66 | 12.72 |
March | 23.68 | 15.42 |
April | 24.27 | 23.31 |
May | 24.34 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.41 | 29.82 |
September | 24.43 | 27.75 |
October | 24.19 | 20.87 |
November | 23.86 | 15.43 |
December | 23.55 | 11.86 |
Annual Sum or Average | 24.09 | 21.71 |
Minimum of Months | 23.55 | 11.86 |
Maximum of Months | 24.43 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.84 | 14.83 |
February | 23.66 | 12.72 |
March | 23.68 | 15.42 |
April | 24.27 | 23.31 |
May | 24.34 | 26.31 |
June | 24.40 | 31.20 |
July | 24.40 | 30.42 |
August | 24.41 | 29.82 |
September | 24.43 | 27.75 |
October | 24.19 | 20.87 |
November | 23.85 | 15.43 |
December | 23.54 | 11.86 |
Annual Sum or Average | 24.09 | 21.71 |
Minimum of Months | 23.54 | 11.86 |
Maximum of Months | 24.43 | 31.20 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2018-10-19 09:40:11
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 25.32 | 14.83 |
February | 24.85 | 12.72 |
March | 25.37 | 15.42 |
April | 27.15 | 23.31 |
May | 27.54 | 26.31 |
June | 28.22 | 31.20 |
July | 28.05 | 30.42 |
August | 27.94 | 29.82 |
September | 27.67 | 27.75 |
October | 26.53 | 20.87 |
November | 25.44 | 15.43 |
December | 24.59 | 11.86 |
Annual Sum or Average | 26.56 | 21.71 |
Minimum of Months | 24.59 | 11.86 |
Maximum of Months | 28.22 | 31.20 |
Report: COMPONENTS OF PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2018-10-19 09:40:11
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W] | |
January | 0.253561E+12 | 158613.452 | 31-JAN-18:15 | 22204.399 | 56867.515 | 24420.975 | 0.000 | 40235.446 | 10720.100 | 1697.548 | 1321.833 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
February | 0.210048E+12 | 131659.958 | 24-FEB-18:15 | 22204.399 | 56867.515 | 24420.975 | 0.000 | 13965.709 | 10720.100 | 1697.548 | 638.076 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
March | 0.242471E+12 | 163121.301 | 18-MAR-17:30 | 22204.399 | 56867.515 | 24420.975 | 0.000 | 54979.731 | 0.000 | 1697.548 | 1805.244 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
April | 0.297707E+12 | 178264.745 | 14-APR-17:30 | 22204.399 | 56867.515 | 24420.975 | 0.000 | 69739.737 | 0.000 | 1697.548 | 2188.683 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
May | 0.326098E+12 | 182337.922 | 31-MAY-17:30 | 22204.399 | 56867.515 | 24420.975 | 0.000 | 73784.531 | 0.000 | 1697.548 | 2217.065 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
June | 0.347719E+12 | 186660.914 | 16-JUN-19:30 | 25049.151 | 49704.829 | 24420.975 | 0.000 | 71861.983 | 10720.100 | 1697.548 | 2260.757 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
July | 0.361125E+12 | 185430.477 | 20-JUL-17:15 | 22204.399 | 56867.515 | 24420.975 | 0.000 | 76405.138 | 0.000 | 1697.548 | 2689.266 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.356011E+12 | 185316.091 | 25-AUG-17:15 | 22204.399 | 56867.515 | 24420.975 | 0.000 | 76488.495 | 0.000 | 1697.548 | 2491.523 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.334173E+12 | 183900.892 | 08-SEP-17:15 | 22204.399 | 56867.515 | 24420.975 | 0.000 | 74843.898 | 0.000 | 1697.548 | 2720.921 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
October | 0.288840E+12 | 178566.753 | 06-OCT-17:00 | 22204.399 | 56867.515 | 24420.975 | 0.000 | 59478.991 | 10720.100 | 1697.548 | 2031.337 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
November | 0.243309E+12 | 165256.282 | 01-NOV-16:45 | 18221.747 | 56933.809 | 24420.975 | 0.000 | 60761.638 | 0.000 | 1697.548 | 2072.123 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
December | 0.244380E+12 | 142684.326 | 22-DEC-17:30 | 18221.747 | 56933.809 | 24420.975 | 0.000 | 28428.869 | 10720.100 | 1697.548 | 1112.837 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.350544E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||||
Minimum of Months | 0.210048E+12 | 131659.958 | 18221.747 | 49704.829 | 24420.975 | 0.000 | 13965.709 | 0.000 | 1697.548 | 638.076 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.361125E+12 | 186660.914 | 25049.151 | 56933.809 | 24420.975 | 0.000 | 76488.495 | 10720.100 | 1697.548 | 2720.921 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: COMPONENTS OF PEAK GAS DEMAND
For: Meter
Timestamp: 2018-10-19 09:40:11
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC [Invalid/Undefined] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT {AT MAX/MIN} [W] | WATERSYSTEMS:GAS {AT MAX/MIN} [W] | WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.907477E+11 | 102796.054 | 01-JAN-07:15 | 0.000 | 0.000 | 0.000 | 102796.054 | 75028.870 | 75028.870 | 27767.184 |
February | 0.807615E+11 | 81235.575 | 02-FEB-07:45 | 0.000 | 0.000 | 0.000 | 81235.575 | 81235.575 | 81235.575 | 0.000 |
March | 0.852066E+11 | 80341.884 | 03-MAR-07:45 | 0.000 | 0.000 | 0.000 | 80341.884 | 80341.884 | 80341.884 | 0.000 |
April | 0.759477E+11 | 78607.652 | 02-APR-06:45 | 0.000 | 0.000 | 0.000 | 78607.652 | 78607.652 | 78607.652 | 0.000 |
May | 0.712227E+11 | 76636.880 | 01-MAY-06:45 | 0.000 | 0.000 | 0.000 | 76636.880 | 76636.880 | 76636.880 | 0.000 |
June | 0.632265E+11 | 68778.479 | 04-JUN-06:00 | 0.000 | 0.000 | 0.000 | 68778.479 | 68778.479 | 68778.479 | 0.000 |
July | 0.624484E+11 | 56563.379 | 11-JUL-06:45 | 0.000 | 0.000 | 0.000 | 56563.379 | 56563.379 | 56563.379 | 0.000 |
August | 0.633171E+11 | 63989.279 | 27-AUG-06:00 | 0.000 | 0.000 | 0.000 | 63989.279 | 63989.279 | 63989.279 | 0.000 |
September | 0.655347E+11 | 75580.302 | 30-SEP-06:00 | 0.000 | 0.000 | 0.000 | 75580.302 | 75580.302 | 75580.302 | 0.000 |
October | 0.744813E+11 | 77610.423 | 31-OCT-06:00 | 0.000 | 0.000 | 0.000 | 77610.423 | 77610.423 | 77610.423 | 0.000 |
November | 0.790426E+11 | 79221.540 | 27-NOV-07:30 | 0.000 | 0.000 | 0.000 | 79221.540 | 79221.540 | 79221.540 | 0.000 |
December | 0.899754E+11 | 105770.419 | 17-DEC-07:30 | 0.000 | 0.000 | 0.000 | 105770.419 | 78424.236 | 78424.236 | 27346.183 |
Annual Sum or Average | 0.901912E+12 | 0.000 | 0.000 | 0.000 | ||||||
Minimum of Months | 0.624484E+11 | 56563.379 | 0.000 | 0.000 | 0.000 | 56563.379 | 56563.379 | 56563.379 | 0.000 | |
Maximum of Months | 0.907477E+11 | 105770.419 | 0.000 | 0.000 | 0.000 | 105770.419 | 81235.575 | 81235.575 | 27767.184 |