Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 10:14
Tabular Output Report in Format: HTML
Building: Small Hotel
Environment: Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695
Simulation Timestamp: 2018-10-19 10:15:39
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2018-10-19 10:15:39
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 2887.57 | 719.45 | 775.17 |
Net Site Energy | 2887.57 | 719.45 | 775.17 |
Total Source Energy | 6798.74 | 1693.93 | 1825.12 |
Net Source Energy | 6798.74 | 1693.93 | 1825.12 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 4013.58 |
Net Conditioned Building Area | 3725.09 |
Unconditioned Building Area | 288.49 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 167.02 | 64.44 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 230.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 414.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 65.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 591.01 | 421.49 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 291.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 640.42 | 0.00 | 0.00 | 0.00 | 2578.25 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1761.22 | 1126.35 | 0.00 | 0.00 | 0.00 | 2578.25 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 167.02 | 64.44 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 230.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | General Lights | 414.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 65.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | General | 562.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ELECTRIC EQUIPMENT#Laundry#05 | 28.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
GAS EQUIPMENT#Laundry#05 | 0.00 | 421.49 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 291.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 640.42 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2578.25 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 128.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 185.19 | 189.22 | 0.00 | 0.00 | 0.00 | 0.69 |
Other | 158.66 | 113.15 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 472.80 | 302.37 | 0.00 | 0.00 | 0.00 | 0.69 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 119.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 171.87 | 175.62 | 0.00 | 0.00 | 0.00 | 0.64 |
Other | 147.25 | 105.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 438.81 | 280.64 | 0.00 | 0.00 | 0.00 | 0.64 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 1761.22 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 1761.22 | 100.00 |
Total On-Site and Utility Electric Sources | 1761.22 | 100.00 |
Total Electricity End Uses | 1761.22 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 2578.25 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 2578.25 | 100.00 |
Total Water End Uses | 2578.25 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 337.25 |
Time Setpoint Not Met During Occupied Cooling | 3561.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 5686.75 |
Table of Contents
TopMONTHLY INDOOR TEMP
| REARSTAIRSFLR1 | CORRIDORFLR1 | REARSTORAGEFLR1 | FRONTLOUNGEFLR1 | RESTROOMFLR1 | MEETINGROOMFLR1 | MECHANICALROOMFLR1 | GUESTROOM101 | GUESTROOM102 | GUESTROOM103 | GUESTROOM104 | GUESTROOM105 | EMPLOYEELOUNGEFLR1 | LAUNDRYROOMFLR1 | ELEVATORCOREFLR1 | EXERCISECENTERFLR1 | FRONTOFFICEFLR1 | FRONTSTAIRSFLR1 | FRONTSTORAGEFLR1 | REARSTAIRSFLR2 | CORRIDORFLR2 | REARSTORAGEFLR2 | GUESTROOM201 | GUESTROOM202_205 | GUESTROOM206_208 | GUESTROOM209_212 | GUESTROOM213 | GUESTROOM214 | GUESTROOM215_218 | ELEVATORCOREFLR2 | GUESTROOM219 | GUESTROOM220_223 | GUESTROOM224 | FRONTSTORAGEFLR2 | FRONTSTAIRSFLR2 | REARSTAIRSFLR3 | CORRIDORFLR3 | REARSTORAGEFLR3 | GUESTROOM301 | GUESTROOM302_305 | GUESTROOM306_308 | GUESTROOM309_312 | GUESTROOM313 | GUESTROOM314 | GUESTROOM315_318 | ELEVATORCOREFLR3 | GUESTROOM319 | GUESTROOM320_323 | GUESTROOM324 | FRONTSTORAGEFLR3 | FRONTSTAIRSFLR3 | REARSTAIRSFLR4 | CORRIDORFLR4 | REARSTORAGEFLR4 | GUESTROOM401 | GUESTROOM402_405 | GUESTROOM406_408 | GUESTROOM409_412 | GUESTROOM413 | GUESTROOM414 | GUESTROOM415_418 | ELEVATORCOREFLR4 | GUESTROOM419 | GUESTROOM420_423 | GUESTROOM424 | FRONTSTORAGEFLR4 | FRONTSTAIRSFLR4 |PEAK ELECTRICAL DEMAND
| Meter |PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2018-10-19 10:15:39
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2018.10.19 10:14 |
RunPeriod | Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695 |
Weather File | Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695 |
Latitude [deg] | 39.72 |
Longitude [deg] | -104.8 |
Elevation [m] | 1726.00 |
Time Zone | -7.0 |
North Axis Angle [deg] | 180.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1694.58 | 635.46 | 211.83 | 635.46 | 211.83 |
Window Opening Area [m2] | 184.20 | 96.82 | 8.38 | 72.38 | 6.62 |
Window-Wall Ratio [%] | 10.87 | 15.24 | 3.95 | 11.39 | 3.13 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1492.32 | 607.21 | 211.83 | 556.77 | 116.50 |
Window Opening Area [m2] | 179.26 | 96.82 | 8.38 | 67.45 | 6.62 |
Window-Wall Ratio [%] | 12.01 | 15.95 | 3.95 | 12.11 | 5.68 |
Total | |
Gross Roof Area [m2] | 1003.40 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
REARSTAIRSFLR1 | 20.07 | Yes | Yes | 67.30 | 1.00 | 35.77 | 0.00 | 7.4271 | 0.0000 | |
CORRIDORFLR1 | 150.51 | Yes | Yes | 504.62 | 1.00 | 32.70 | 9.82 | 8.5250 | 0.0000 | |
REARSTORAGEFLR1 | 20.07 | No | Yes | 67.30 | 1.00 | 35.77 | 0.00 | 6.7813 | 0.0000 | |
FRONTLOUNGEFLR1 | 163.06 | Yes | Yes | 546.70 | 1.00 | 94.02 | 14.83 | 11.4097 | 3.08 | 26.0600 |
RESTROOMFLR1 | 32.61 | Yes | Yes | 109.34 | 1.00 | 13.29 | 0.00 | 10.5486 | 32.61 | 0.0000 |
MEETINGROOMFLR1 | 80.27 | Yes | Yes | 269.14 | 1.00 | 32.70 | 4.94 | 13.2396 | 1.87 | 6.1800 |
MECHANICALROOMFLR1 | 32.61 | Yes | Yes | 109.34 | 1.00 | 13.29 | 0.00 | 10.2257 | 0.0000 | |
GUESTROOM101 | 32.61 | Yes | Yes | 109.34 | 1.00 | 13.29 | 1.65 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM102 | 32.61 | Yes | Yes | 109.34 | 1.00 | 13.29 | 1.65 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM103 | 32.61 | Yes | Yes | 109.34 | 1.00 | 13.29 | 1.65 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM104 | 32.61 | Yes | Yes | 109.33 | 1.00 | 13.29 | 1.65 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM105 | 32.61 | Yes | Yes | 109.33 | 1.00 | 13.29 | 1.65 | 8.0729 | 21.74 | 11.8935 |
EMPLOYEELOUNGEFLR1 | 32.61 | Yes | Yes | 109.33 | 1.00 | 13.29 | 1.65 | 7.8577 | 1.81 | 21.5100 |
LAUNDRYROOMFLR1 | 97.83 | No | Yes | 327.99 | 1.00 | 39.86 | 4.94 | 6.4583 | 8.89 | 437.5596 |
ELEVATORCOREFLR1 | 15.05 | No | Yes | 50.46 | 1.00 | 6.13 | 0.00 | 0.0000 | 2147.5789 | |
EXERCISECENTERFLR1 | 32.61 | Yes | Yes | 109.33 | 1.00 | 13.29 | 1.65 | 9.3000 | 4.66 | 18.5900 |
FRONTOFFICEFLR1 | 130.44 | Yes | Yes | 437.33 | 1.00 | 53.14 | 6.58 | 11.9479 | 13.04 | 13.7800 |
FRONTSTAIRSFLR1 | 20.07 | Yes | Yes | 67.28 | 1.00 | 35.77 | 0.00 | 7.4271 | 0.0000 | |
FRONTSTORAGEFLR1 | 12.54 | No | Yes | 42.05 | 1.00 | 5.11 | 0.00 | 6.7813 | 0.0000 | |
REARSTAIRSFLR2 | 20.07 | Yes | Yes | 55.06 | 1.00 | 29.27 | 0.00 | 7.4271 | 0.0000 | |
CORRIDORFLR2 | 125.42 | Yes | Yes | 344.05 | 1.00 | 18.39 | 2.62 | 8.5250 | 0.0000 | |
REARSTORAGEFLR2 | 20.07 | No | Yes | 55.07 | 1.00 | 29.27 | 0.00 | 6.7813 | 0.0000 | |
GUESTROOM201 | 32.61 | Yes | Yes | 89.46 | 1.00 | 33.45 | 1.65 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM202_205 | 130.45 | Yes | Yes | 357.84 | 1.00 | 43.48 | 6.58 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM206_208 | 105.36 | Yes | Yes | 289.02 | 1.00 | 35.12 | 6.70 | 8.0729 | 23.41 | 11.8935 |
GUESTROOM209_212 | 130.45 | Yes | Yes | 357.84 | 1.00 | 43.48 | 6.58 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM213 | 32.61 | Yes | Yes | 89.46 | 1.00 | 10.87 | 1.65 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM214 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 1.65 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM215_218 | 130.44 | Yes | Yes | 357.81 | 1.00 | 43.48 | 6.58 | 8.0729 | 21.74 | 11.8935 |
ELEVATORCOREFLR2 | 15.05 | No | Yes | 41.29 | 1.00 | 5.02 | 0.00 | 0.0000 | 0.0000 | |
GUESTROOM219 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 1.65 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM220_223 | 130.44 | Yes | Yes | 357.81 | 1.00 | 43.48 | 6.58 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM224 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 1.65 | 8.0729 | 21.74 | 11.8935 |
FRONTSTORAGEFLR2 | 12.54 | No | Yes | 34.40 | 1.00 | 4.18 | 0.00 | 6.7813 | 0.0000 | |
FRONTSTAIRSFLR2 | 20.07 | Yes | Yes | 55.05 | 1.00 | 29.26 | 0.00 | 7.4271 | 0.0000 | |
REARSTAIRSFLR3 | 20.07 | Yes | Yes | 55.06 | 1.00 | 29.27 | 0.00 | 7.4271 | 0.0000 | |
CORRIDORFLR3 | 125.42 | Yes | Yes | 344.05 | 1.00 | 18.39 | 2.62 | 8.5250 | 0.0000 | |
REARSTORAGEFLR3 | 20.07 | No | Yes | 55.07 | 1.00 | 29.27 | 0.00 | 6.7813 | 0.0000 | |
GUESTROOM301 | 32.61 | Yes | Yes | 89.46 | 1.00 | 33.45 | 1.65 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM302_305 | 130.45 | Yes | Yes | 357.84 | 1.00 | 43.48 | 6.58 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM306_308 | 105.36 | Yes | Yes | 289.02 | 1.00 | 35.12 | 6.70 | 8.0729 | 23.41 | 11.8935 |
GUESTROOM309_312 | 130.45 | Yes | Yes | 357.84 | 1.00 | 43.48 | 6.58 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM313 | 32.61 | Yes | Yes | 89.46 | 1.00 | 10.87 | 1.65 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM314 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 1.65 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM315_318 | 130.44 | Yes | Yes | 357.81 | 1.00 | 43.48 | 6.58 | 8.0729 | 21.74 | 11.8935 |
ELEVATORCOREFLR3 | 15.05 | No | Yes | 41.29 | 1.00 | 5.02 | 0.00 | 0.0000 | 0.0000 | |
GUESTROOM319 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 1.65 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM320_323 | 130.44 | Yes | Yes | 357.81 | 1.00 | 43.48 | 6.58 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM324 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 1.65 | 8.0729 | 21.74 | 11.8935 |
FRONTSTORAGEFLR3 | 12.54 | No | Yes | 34.40 | 1.00 | 4.18 | 0.00 | 6.7813 | 0.0000 | |
FRONTSTAIRSFLR3 | 20.07 | Yes | Yes | 55.05 | 1.00 | 29.26 | 0.00 | 7.4271 | 0.0000 | |
REARSTAIRSFLR4 | 20.07 | Yes | Yes | 55.06 | 1.00 | 29.27 | 0.00 | 7.4271 | 0.0000 | |
CORRIDORFLR4 | 125.42 | Yes | Yes | 344.05 | 1.00 | 18.39 | 2.62 | 8.5250 | 0.0000 | |
REARSTORAGEFLR4 | 20.07 | No | Yes | 55.07 | 1.00 | 29.27 | 0.00 | 6.7813 | 0.0000 | |
GUESTROOM401 | 32.61 | Yes | Yes | 89.46 | 1.00 | 33.45 | 1.65 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM402_405 | 130.45 | Yes | Yes | 357.84 | 1.00 | 43.48 | 6.58 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM406_408 | 105.36 | Yes | Yes | 289.02 | 1.00 | 35.12 | 6.70 | 8.0729 | 23.41 | 11.8935 |
GUESTROOM409_412 | 130.45 | Yes | Yes | 357.84 | 1.00 | 43.48 | 6.58 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM413 | 32.61 | Yes | Yes | 89.46 | 1.00 | 10.87 | 1.65 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM414 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 1.65 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM415_418 | 130.44 | Yes | Yes | 357.81 | 1.00 | 43.48 | 6.58 | 8.0729 | 21.74 | 11.8935 |
ELEVATORCOREFLR4 | 15.05 | No | Yes | 41.29 | 1.00 | 5.02 | 0.00 | 0.0000 | 0.0000 | |
GUESTROOM419 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 1.65 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM420_423 | 130.44 | Yes | Yes | 357.81 | 1.00 | 43.48 | 6.58 | 8.0729 | 21.74 | 11.8935 |
GUESTROOM424 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 1.65 | 8.0729 | 21.74 | 11.8935 |
FRONTSTORAGEFLR4 | 12.54 | No | Yes | 34.40 | 1.00 | 4.18 | 0.00 | 6.7813 | 0.0000 | |
FRONTSTAIRSFLR4 | 20.07 | Yes | Yes | 55.05 | 1.00 | 29.26 | 0.00 | 7.4271 | 0.0000 | |
Total | 4013.58 | 11621.73 | 1694.58 | 184.20 | 8.3147 | 15.53 | 28.1818 | |||
Conditioned Total | 3725.09 | 10741.65 | 1492.32 | 179.26 | 8.5515 | 15.05 | 10.1966 | |||
Unconditioned Total | 288.49 | 880.07 | 202.26 | 4.94 | 5.2567 | 26.23 | 260.4149 | |||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2018-10-19 10:15:39
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | -17.90 | 0.00 | -17.90 | Wetbulb [C] | 2.50 | 180.00 |
DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 33.90 | 14.80 | 15.00 | Wetbulb [C] | 3.60 | 30.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2018-10-19 10:15:39
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
W_REARSTAIRSFLR1_2_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 27.59 | 270.00 | 90.00 | W |
W_REARSTAIRSFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 8.18 | 180.00 | 90.00 | S |
S_REARSTAIRSFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 20.07 | 180.00 | 180.00 | |
W_CORRIDORFLR1_2_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.13 | 270.00 | 90.00 | W |
W_CORRIDORFLR1_10_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.22 | 180.00 | 90.00 | S |
W_CORRIDORFLR1_16_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.13 | 90.00 | 90.00 | E |
W_CORRIDORFLR1_20_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.22 | 0.00 | 90.00 | N |
S_CORRIDORFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 150.51 | 180.00 | 180.00 | |
W_REARSTORAGEFLR1_2_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 27.59 | 270.00 | 90.00 | W |
W_REARSTORAGEFLR1_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 8.18 | 0.00 | 90.00 | N |
S_REARSTORAGEFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 20.07 | 180.00 | 180.00 | |
W_FRONTLOUNGEFLR1_4_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 27.59 | 90.00 | 90.00 | E |
W_FRONTLOUNGEFLR1_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 66.43 | 0.00 | 90.00 | N |
S_FRONTLOUNGEFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 163.06 | 180.00 | 180.00 | |
W_RESTROOMFLR1_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 13.29 | 0.00 | 90.00 | N |
S_RESTROOMFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 32.61 | 180.00 | 180.00 | |
W_MEETINGROOMFLR1_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 32.70 | 0.00 | 90.00 | N |
S_MEETINGROOMFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 80.27 | 180.00 | 180.00 | |
W_MECHANICALROOMFLR1_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 13.29 | 0.00 | 90.00 | N |
S_MECHANICALROOMFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 32.61 | 180.00 | 180.00 | |
W_GUESTROOM101_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 13.29 | 0.00 | 90.00 | N |
S_GUESTROOM101_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 32.61 | 180.00 | 180.00 | |
W_GUESTROOM102_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 13.29 | 0.00 | 90.00 | N |
S_GUESTROOM102_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 32.61 | 180.00 | 180.00 | |
W_GUESTROOM103_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 13.29 | 0.00 | 90.00 | N |
S_GUESTROOM103_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 32.61 | 180.00 | 180.00 | |
W_GUESTROOM104_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 13.29 | 180.00 | 90.00 | S |
S_GUESTROOM104_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 32.61 | 180.00 | 180.00 | |
W_GUESTROOM105_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 13.29 | 180.00 | 90.00 | S |
S_GUESTROOM105_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 32.61 | 180.00 | 180.00 | |
W_EMPLOYEELOUNGEFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 13.29 | 180.00 | 90.00 | S |
S_EMPLOYEELOUNGEFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 32.61 | 180.00 | 180.00 | |
W_LAUNDRYROOMFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.86 | 180.00 | 90.00 | S |
S_LAUNDRYROOMFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 97.83 | 180.00 | 180.00 | |
W_ELEVATORCOREFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.13 | 180.00 | 90.00 | S |
S_ELEVATORCOREFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 15.05 | 180.00 | 180.00 | |
W_EXERCISECENTERFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 13.29 | 180.00 | 90.00 | S |
S_EXERCISECENTERFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 32.61 | 180.00 | 180.00 | |
W_FRONTOFFICEFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 53.14 | 180.00 | 90.00 | S |
S_FRONTOFFICEFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 130.44 | 180.00 | 180.00 | |
W_FRONTSTAIRSFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 8.18 | 180.00 | 90.00 | S |
W_FRONTSTAIRSFLR1_4_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 27.59 | 90.00 | 90.00 | E |
S_FRONTSTAIRSFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 20.07 | 180.00 | 180.00 | |
W_FRONTSTORAGEFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 180.00 | 90.00 | S |
S_FRONTSTORAGEFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 12.54 | 180.00 | 180.00 | |
W_REARSTAIRSFLR2_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 270.00 | 90.00 | W |
W_REARSTAIRSFLR2_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 180.00 | 90.00 | S |
W_CORRIDORFLR2_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 270.00 | 90.00 | W |
W_CORRIDORFLR2_9_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 8.36 | 180.00 | 90.00 | S |
W_CORRIDORFLR2_15_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 90.00 | 90.00 | E |
W_REARSTORAGEFLR2_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 270.00 | 90.00 | W |
W_REARSTORAGEFLR2_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 0.00 | 90.00 | N |
W_GUESTROOM201_4_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 90.00 | 90.00 | E |
W_GUESTROOM201_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 0.00 | 90.00 | N |
W_GUESTROOM202_205_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 0.00 | 90.00 | N |
W_GUESTROOM206_208_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.12 | 0.00 | 90.00 | N |
W_GUESTROOM209_212_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 0.00 | 90.00 | N |
W_GUESTROOM213_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 0.00 | 90.00 | N |
W_GUESTROOM214_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 180.00 | 90.00 | S |
W_GUESTROOM215_218_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 180.00 | 90.00 | S |
W_ELEVATORCOREFLR2_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 180.00 | 90.00 | S |
W_GUESTROOM219_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 180.00 | 90.00 | S |
W_GUESTROOM220_223_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 180.00 | 90.00 | S |
W_GUESTROOM224_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 180.00 | 90.00 | S |
W_FRONTSTORAGEFLR2_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 4.18 | 180.00 | 90.00 | S |
W_FRONTSTAIRSFLR2_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 180.00 | 90.00 | S |
W_FRONTSTAIRSFLR2_4_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 90.00 | 90.00 | E |
W_REARSTAIRSFLR3_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 270.00 | 90.00 | W |
W_REARSTAIRSFLR3_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 180.00 | 90.00 | S |
W_CORRIDORFLR3_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 270.00 | 90.00 | W |
W_CORRIDORFLR3_9_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 8.36 | 180.00 | 90.00 | S |
W_CORRIDORFLR3_15_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 90.00 | 90.00 | E |
W_REARSTORAGEFLR3_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 270.00 | 90.00 | W |
W_REARSTORAGEFLR3_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 0.00 | 90.00 | N |
W_GUESTROOM301_4_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 90.00 | 90.00 | E |
W_GUESTROOM301_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 0.00 | 90.00 | N |
W_GUESTROOM302_305_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 0.00 | 90.00 | N |
W_GUESTROOM306_308_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.12 | 0.00 | 90.00 | N |
W_GUESTROOM309_312_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 0.00 | 90.00 | N |
W_GUESTROOM313_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 0.00 | 90.00 | N |
W_GUESTROOM314_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 180.00 | 90.00 | S |
W_GUESTROOM315_318_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 180.00 | 90.00 | S |
W_ELEVATORCOREFLR3_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 180.00 | 90.00 | S |
W_GUESTROOM319_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 180.00 | 90.00 | S |
W_GUESTROOM320_323_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 180.00 | 90.00 | S |
W_GUESTROOM324_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 180.00 | 90.00 | S |
W_FRONTSTORAGEFLR3_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 4.18 | 180.00 | 90.00 | S |
W_FRONTSTAIRSFLR3_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 180.00 | 90.00 | S |
W_FRONTSTAIRSFLR3_4_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 90.00 | 90.00 | E |
W_REARSTAIRSFLR4_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 270.00 | 90.00 | W |
W_REARSTAIRSFLR4_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 180.00 | 90.00 | S |
R_REARSTAIRSFLR4_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 20.07 | 0.00 | 0.00 | |
W_CORRIDORFLR4_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 270.00 | 90.00 | W |
W_CORRIDORFLR4_9_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 8.36 | 180.00 | 90.00 | S |
W_CORRIDORFLR4_15_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 90.00 | 90.00 | E |
R_CORRIDORFLR4_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 125.42 | 0.00 | 0.00 | |
W_REARSTORAGEFLR4_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 270.00 | 90.00 | W |
W_REARSTORAGEFLR4_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 0.00 | 90.00 | N |
R_REARSTORAGEFLR4_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 20.07 | 0.00 | 0.00 | |
W_GUESTROOM401_4_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 90.00 | 90.00 | E |
W_GUESTROOM401_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 0.00 | 90.00 | N |
R_GUESTROOM401_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 32.61 | 0.00 | 0.00 | |
W_GUESTROOM402_405_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 0.00 | 90.00 | N |
R_GUESTROOM402_405_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 130.45 | 0.00 | 0.00 | |
W_GUESTROOM406_408_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.12 | 0.00 | 90.00 | N |
R_GUESTROOM406_408_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 105.36 | 0.00 | 0.00 | |
W_GUESTROOM409_412_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 0.00 | 90.00 | N |
R_GUESTROOM409_412_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 130.45 | 0.00 | 0.00 | |
W_GUESTROOM413_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 0.00 | 90.00 | N |
R_GUESTROOM413_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 32.61 | 0.00 | 0.00 | |
W_GUESTROOM414_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 180.00 | 90.00 | S |
R_GUESTROOM414_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 32.61 | 0.00 | 0.00 | |
W_GUESTROOM415_418_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 180.00 | 90.00 | S |
R_GUESTROOM415_418_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 130.44 | 0.00 | 0.00 | |
W_ELEVATORCOREFLR4_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 180.00 | 90.00 | S |
R_ELEVATORCOREFLR4_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 15.05 | 0.00 | 0.00 | |
W_GUESTROOM419_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 180.00 | 90.00 | S |
R_GUESTROOM419_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 32.61 | 0.00 | 0.00 | |
W_GUESTROOM420_423_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 180.00 | 90.00 | S |
R_GUESTROOM420_423_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 130.44 | 0.00 | 0.00 | |
W_GUESTROOM424_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 180.00 | 90.00 | S |
R_GUESTROOM424_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 32.61 | 0.00 | 0.00 | |
W_FRONTSTORAGEFLR4_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 4.18 | 180.00 | 90.00 | S |
R_FRONTSTORAGEFLR4_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 12.54 | 0.00 | 0.00 | |
W_FRONTSTAIRSFLR4_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 180.00 | 90.00 | S |
W_FRONTSTAIRSFLR4_4_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 90.00 | 90.00 | E |
R_FRONTSTAIRSFLR4_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 20.07 | 0.00 | 0.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
W_CORRIDORFLR1_2_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 2.69 | 0.00 | 0.00 | 2.69 | 2.69 | 2.653 | 0.426 | 0.308 | No | W_CORRIDORFLR1_2_0_0 | 270.00 | 90.00 | W | ||
D_CORRIDORFLR1_16_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 4.44 | 0.00 | 0.00 | 4.44 | 4.44 | 2.653 | 0.426 | 0.308 | No | W_CORRIDORFLR1_16_0_0 | 90.00 | 90.00 | E | ||
W_CORRIDORFLR1_20_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 2.69 | 0.00 | 0.00 | 2.69 | 2.69 | 2.653 | 0.426 | 0.308 | No | W_CORRIDORFLR1_20_0_0 | 0.00 | 90.00 | N | ||
W_FRONTLOUNGEFLR1_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 2.97 | 0.00 | 0.00 | 2.97 | 2.97 | 2.653 | 0.426 | 0.308 | No | W_FRONTLOUNGEFLR1_5_0_0 | 0.00 | 90.00 | N | ||
W_FRONTLOUNGEFLR1_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 2.97 | 0.00 | 0.00 | 2.97 | 2.97 | 2.653 | 0.426 | 0.308 | No | W_FRONTLOUNGEFLR1_5_0_0 | 0.00 | 90.00 | N | ||
W_FRONTLOUNGEFLR1_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 2.97 | 0.00 | 0.00 | 2.97 | 2.97 | 2.653 | 0.426 | 0.308 | No | W_FRONTLOUNGEFLR1_5_0_0 | 0.00 | 90.00 | N | ||
W_FRONTLOUNGEFLR1_5_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 2.97 | 0.00 | 0.00 | 2.97 | 2.97 | 2.653 | 0.426 | 0.308 | No | W_FRONTLOUNGEFLR1_5_0_0 | 0.00 | 90.00 | N | ||
W_FRONTLOUNGEFLR1_5_0_0_0_4 | WINDOW_U_0.52_SHGC_0.40 | 2.97 | 0.00 | 0.00 | 2.97 | 2.97 | 2.653 | 0.426 | 0.308 | No | W_FRONTLOUNGEFLR1_5_0_0 | 0.00 | 90.00 | N | ||
W_MEETINGROOMFLR1_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_MEETINGROOMFLR1_5_0_0 | 0.00 | 90.00 | N | ||
W_MEETINGROOMFLR1_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_MEETINGROOMFLR1_5_0_0 | 0.00 | 90.00 | N | ||
W_MEETINGROOMFLR1_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_MEETINGROOMFLR1_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM101_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM101_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM102_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM102_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM103_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM103_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM104_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM104_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM105_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM105_3_0_0 | 180.00 | 90.00 | S | ||
W_EMPLOYEELOUNGEFLR1_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_EMPLOYEELOUNGEFLR1_3_0_0 | 180.00 | 90.00 | S | ||
W_LAUNDRYROOMFLR1_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_LAUNDRYROOMFLR1_3_0_0 | 180.00 | 90.00 | S | ||
W_LAUNDRYROOMFLR1_3_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_LAUNDRYROOMFLR1_3_0_0 | 180.00 | 90.00 | S | ||
W_LAUNDRYROOMFLR1_3_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_LAUNDRYROOMFLR1_3_0_0 | 180.00 | 90.00 | S | ||
W_EXERCISECENTERFLR1_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_EXERCISECENTERFLR1_3_0_0 | 180.00 | 90.00 | S | ||
W_FRONTOFFICEFLR1_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_FRONTOFFICEFLR1_3_0_0 | 180.00 | 90.00 | S | ||
W_FRONTOFFICEFLR1_3_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_FRONTOFFICEFLR1_3_0_0 | 180.00 | 90.00 | S | ||
W_FRONTOFFICEFLR1_3_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_FRONTOFFICEFLR1_3_0_0 | 180.00 | 90.00 | S | ||
W_FRONTOFFICEFLR1_3_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_FRONTOFFICEFLR1_3_0_0 | 180.00 | 90.00 | S | ||
W_CORRIDORFLR2_2_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.31 | 0.00 | 0.00 | 1.31 | 1.31 | 2.653 | 0.426 | 0.308 | No | W_CORRIDORFLR2_2_0_0 | 270.00 | 90.00 | W | ||
W_CORRIDORFLR2_15_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.31 | 0.00 | 0.00 | 1.31 | 1.31 | 2.653 | 0.426 | 0.308 | No | W_CORRIDORFLR2_15_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM201_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM201_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM202_205_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM202_205_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM202_205_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM202_205_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM202_205_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM202_205_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM202_205_5_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM202_205_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM206_208_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM206_208_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM206_208_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 3.41 | 0.00 | 0.00 | 3.41 | 3.41 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM206_208_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM206_208_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM206_208_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM209_212_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM209_212_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM209_212_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM209_212_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM209_212_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM209_212_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM209_212_5_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM209_212_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM213_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM213_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM214_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM214_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM215_218_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM215_218_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM215_218_3_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM215_218_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM215_218_3_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM215_218_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM215_218_3_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM215_218_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM219_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM219_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM220_223_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM220_223_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM220_223_3_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM220_223_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM220_223_3_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM220_223_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM220_223_3_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM220_223_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM224_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM224_3_0_0 | 180.00 | 90.00 | S | ||
W_CORRIDORFLR3_2_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.31 | 0.00 | 0.00 | 1.31 | 1.31 | 2.653 | 0.426 | 0.308 | No | W_CORRIDORFLR3_2_0_0 | 270.00 | 90.00 | W | ||
W_CORRIDORFLR3_15_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.31 | 0.00 | 0.00 | 1.31 | 1.31 | 2.653 | 0.426 | 0.308 | No | W_CORRIDORFLR3_15_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM301_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM301_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM302_305_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM302_305_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM302_305_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM302_305_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM302_305_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM302_305_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM302_305_5_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM302_305_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM306_308_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM306_308_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM306_308_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 3.41 | 0.00 | 0.00 | 3.41 | 3.41 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM306_308_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM306_308_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM306_308_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM309_312_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM309_312_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM309_312_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM309_312_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM309_312_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM309_312_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM309_312_5_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM309_312_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM313_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM313_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM314_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM314_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM315_318_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM315_318_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM315_318_3_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM315_318_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM315_318_3_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM315_318_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM315_318_3_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM315_318_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM319_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM319_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM320_323_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM320_323_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM320_323_3_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM320_323_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM320_323_3_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM320_323_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM320_323_3_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM320_323_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM324_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM324_3_0_0 | 180.00 | 90.00 | S | ||
W_CORRIDORFLR4_2_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.31 | 0.00 | 0.00 | 1.31 | 1.31 | 2.653 | 0.426 | 0.308 | No | W_CORRIDORFLR4_2_0_0 | 270.00 | 90.00 | W | ||
W_CORRIDORFLR4_15_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.31 | 0.00 | 0.00 | 1.31 | 1.31 | 2.653 | 0.426 | 0.308 | No | W_CORRIDORFLR4_15_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM401_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM401_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM402_405_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM402_405_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM402_405_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM402_405_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM402_405_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM402_405_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM402_405_5_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM402_405_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM406_408_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM406_408_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM406_408_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM406_408_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM406_408_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 3.41 | 0.00 | 0.00 | 3.41 | 3.41 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM406_408_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM409_412_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM409_412_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM409_412_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM409_412_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM409_412_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM409_412_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM409_412_5_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM409_412_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM413_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM413_5_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM414_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM414_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM415_418_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM415_418_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM415_418_3_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM415_418_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM415_418_3_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM415_418_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM415_418_3_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM415_418_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM419_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM419_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM420_423_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM420_423_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM420_423_3_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM420_423_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM420_423_3_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM420_423_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM420_423_3_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM420_423_3_0_0 | 180.00 | 90.00 | S | ||
W_GUESTROOM424_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM424_3_0_0 | 180.00 | 90.00 | S | ||
Total or Average | 184.20 | 2.653 | 0.426 | 0.308 | ||||||||||||
North Total or Average | 96.82 | 2.653 | 0.426 | 0.308 | ||||||||||||
Non-North Total or Average | 87.38 | 2.653 | 0.426 | 0.308 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
W_REARSTAIRSFLR1_3_0_0_DOOR | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | W_REARSTAIRSFLR1_3_0_0 |
W_CORRIDORFLR1_10_0_0_DOOR | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | W_CORRIDORFLR1_10_0_0 |
W_FRONTSTAIRSFLR1_3_0_0_DOOR | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | W_FRONTSTAIRSFLR1_3_0_0 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2018-10-19 10:15:39
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
CORRIDORFLR1 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
101 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
102 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
103 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
104 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
105 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
CORRIDORFLR2 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
201 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
202_205 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.73 | |||
206_208 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7913.25 | 5780.50 | 2132.75 | 0.73 | 3.73 | |||
209_212 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.73 | |||
213 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
214 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
215_218 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.73 | |||
219 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
220_223 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.73 | |||
224 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
CORRIDORFLR3 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
301 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
302_305 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.73 | |||
306_308 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7913.25 | 5780.50 | 2132.75 | 0.73 | 3.73 | |||
309_312 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.73 | |||
313 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
314 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
315_318 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.73 | |||
319 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
320_323 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.73 | |||
324 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
CORRIDORFLR4 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
401 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
402_405 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.73 | |||
406_408 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7913.25 | 5780.50 | 2132.75 | 0.73 | 3.73 | |||
409_412 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.73 | |||
413 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
414 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
415_418 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.73 | |||
419 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
420_423 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.73 | |||
424 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.73 | |||
SAC_FRONTOFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6222.67 | 4969.77 | 1252.90 | 0.80 | 3.91 | |||
SAC_FRONTLOUNGE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 15616.75 | 12195.49 | 3421.26 | 0.78 | 3.91 | |||
SAC_MEETINGROOM COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8239.09 | 6141.25 | 2097.85 | 0.75 | 3.91 | |||
SAC_EXC_EMPLGE_RESTRM COOLING COIL | Coil:Cooling:DX:SingleSpeed | 14027.18 | 11202.88 | 2824.30 | 0.80 | 3.91 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
CORRIDORFLR1 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
101 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
102 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
103 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
104 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
105 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
CORRIDORFLR2 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
201 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
202_205 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.14 | 10.72 | 11.36 | 10.75 |
206_208 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7610.9 | 3.14 | 10.72 | 11.36 | 10.75 |
209_212 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.14 | 10.72 | 11.36 | 10.75 |
213 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
214 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
215_218 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.14 | 10.72 | 11.36 | 10.75 |
219 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
220_223 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.14 | 10.72 | 11.36 | 10.75 |
224 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
CORRIDORFLR3 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
301 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
302_305 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.14 | 10.72 | 11.36 | 10.75 |
306_308 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7610.9 | 3.14 | 10.72 | 11.36 | 10.75 |
309_312 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.14 | 10.72 | 11.36 | 10.75 |
313 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
314 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
315_318 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.14 | 10.72 | 11.36 | 10.75 |
319 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
320_323 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.14 | 10.72 | 11.36 | 10.75 |
324 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
CORRIDORFLR4 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
401 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
402_405 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.14 | 10.72 | 11.36 | 10.75 |
406_408 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7610.9 | 3.14 | 10.72 | 11.36 | 10.75 |
409_412 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.14 | 10.72 | 11.36 | 10.75 |
413 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
414 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
415_418 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.14 | 10.72 | 11.36 | 10.75 |
419 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
420_423 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.14 | 10.72 | 11.36 | 10.75 |
424 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.14 | 10.72 | 11.36 | 10.75 |
SAC_FRONTOFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5931.0 | 3.15 | 10.76 | 11.39 | 10.54 |
SAC_FRONTLOUNGE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 14919.9 | 3.18 | 10.86 | 11.50 | 10.69 |
SAC_MEETINGROOM COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7908.7 | 3.25 | 11.08 | 11.74 | 11.01 |
SAC_EXC_EMPLGE_RESTRM COOLING COIL | Coil:Cooling:DX:SingleSpeed | 13369.6 | 3.15 | 10.76 | 11.39 | 10.54 |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
REARSTAIRSFLR1UNITHEATERHEATINGCOIL | Coil:Heating:Electric | 260.88 | 1.00 | |
CORRIDORFLR1 PTAC HEATING COIL | Coil:Heating:Electric | 25205.09 | 1.00 | |
MECHRMUNITHEATERHEATINGCOIL | Coil:Heating:Electric | 0.00 | 1.00 | |
101 PTAC HEATING COIL | Coil:Heating:Electric | 911.88 | 1.00 | |
102 PTAC HEATING COIL | Coil:Heating:Electric | 911.88 | 1.00 | |
103 PTAC HEATING COIL | Coil:Heating:Electric | 1164.60 | 1.00 | |
104 PTAC HEATING COIL | Coil:Heating:Electric | 1162.48 | 1.00 | |
105 PTAC HEATING COIL | Coil:Heating:Electric | 911.81 | 1.00 | |
FRONTSTAIRSFLR1UNITHEATERHEATINGCOIL | Coil:Heating:Electric | 260.82 | 1.00 | |
REARSTAIRSFLR2UNITHEATERHEATINGCOIL | Coil:Heating:Electric | 260.88 | 1.00 | |
CORRIDORFLR2 PTAC HEATING COIL | Coil:Heating:Electric | 2586.13 | 1.00 | |
201 PTAC HEATING COIL | Coil:Heating:Electric | 1145.31 | 1.00 | |
202_205 PTAC HEATING COIL | Coil:Heating:Electric | 3647.51 | 1.00 | |
206_208 PTAC HEATING COIL | Coil:Heating:Electric | 2890.77 | 1.00 | |
209_212 PTAC HEATING COIL | Coil:Heating:Electric | 3647.51 | 1.00 | |
213 PTAC HEATING COIL | Coil:Heating:Electric | 1201.88 | 1.00 | |
214 PTAC HEATING COIL | Coil:Heating:Electric | 1168.74 | 1.00 | |
215_218 PTAC HEATING COIL | Coil:Heating:Electric | 3647.25 | 1.00 | |
219 PTAC HEATING COIL | Coil:Heating:Electric | 911.81 | 1.00 | |
220_223 PTAC HEATING COIL | Coil:Heating:Electric | 3647.25 | 1.00 | |
224 PTAC HEATING COIL | Coil:Heating:Electric | 1075.99 | 1.00 | |
FRONTSTAIRSFLR2UNITHEATERHEATINGCOIL | Coil:Heating:Electric | 260.82 | 1.00 | |
REARSTAIRSFLR3UNITHEATERHEATINGCOIL | Coil:Heating:Electric | 260.88 | 1.00 | |
CORRIDORFLR3 PTAC HEATING COIL | Coil:Heating:Electric | 2609.51 | 1.00 | |
301 PTAC HEATING COIL | Coil:Heating:Electric | 1200.62 | 1.00 | |
302_305 PTAC HEATING COIL | Coil:Heating:Electric | 3647.51 | 1.00 | |
306_308 PTAC HEATING COIL | Coil:Heating:Electric | 2913.09 | 1.00 | |
309_312 PTAC HEATING COIL | Coil:Heating:Electric | 3647.51 | 1.00 | |
313 PTAC HEATING COIL | Coil:Heating:Electric | 1303.54 | 1.00 | |
314 PTAC HEATING COIL | Coil:Heating:Electric | 1260.19 | 1.00 | |
315_318 PTAC HEATING COIL | Coil:Heating:Electric | 3647.25 | 1.00 | |
319 PTAC HEATING COIL | Coil:Heating:Electric | 927.76 | 1.00 | |
320_323 PTAC HEATING COIL | Coil:Heating:Electric | 3647.25 | 1.00 | |
324 PTAC HEATING COIL | Coil:Heating:Electric | 1178.21 | 1.00 | |
FRONTSTAIRSFLR3UNITHEATERHEATINGCOIL | Coil:Heating:Electric | 260.82 | 1.00 | |
REARSTAIRSFLR4UNITHEATERHEATINGCOIL | Coil:Heating:Electric | 260.88 | 1.00 | |
CORRIDORFLR4 PTAC HEATING COIL | Coil:Heating:Electric | 4098.96 | 1.00 | |
401 PTAC HEATING COIL | Coil:Heating:Electric | 1529.09 | 1.00 | |
402_405 PTAC HEATING COIL | Coil:Heating:Electric | 4726.87 | 1.00 | |
406_408 PTAC HEATING COIL | Coil:Heating:Electric | 3875.43 | 1.00 | |
409_412 PTAC HEATING COIL | Coil:Heating:Electric | 4737.56 | 1.00 | |
413 PTAC HEATING COIL | Coil:Heating:Electric | 1687.52 | 1.00 | |
414 PTAC HEATING COIL | Coil:Heating:Electric | 1641.99 | 1.00 | |
415_418 PTAC HEATING COIL | Coil:Heating:Electric | 4733.78 | 1.00 | |
419 PTAC HEATING COIL | Coil:Heating:Electric | 1300.45 | 1.00 | |
420_423 PTAC HEATING COIL | Coil:Heating:Electric | 4685.67 | 1.00 | |
424 PTAC HEATING COIL | Coil:Heating:Electric | 1559.96 | 1.00 | |
FRONTSTAIRSFLR4UNITHEATERHEATINGCOIL | Coil:Heating:Electric | 413.78 | 1.00 | |
SAC_FRONTOFFICE HEATING COIL | Coil:Heating:Gas | 3754.70 | 0.80 | |
SAC_FRONTLOUNGE HEATING COIL | Coil:Heating:Gas | 15737.76 | 0.80 | |
SAC_MEETINGROOM HEATING COIL | Coil:Heating:Gas | 8427.45 | 0.80 | |
SAC_EXC_EMPLGE_RESTRM HEATING COIL | Coil:Heating:Gas | 6442.16 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
REARSTAIRSFLR1UNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 0.01 | 0.57 | 92.91 | 1.00 | General |
CORRIDORFLR1 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
MECHRMUNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 0.00 | 0.00 | 1.00 | General | |
101 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
102 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
103 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
104 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
105 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
FRONTSTAIRSFLR1UNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 0.01 | 0.57 | 92.91 | 1.00 | General |
REARSTAIRSFLR2UNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 0.01 | 0.57 | 92.91 | 1.00 | General |
CORRIDORFLR2 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
201 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
202_205 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
206_208 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.39 | 248.38 | 636.87 | 1.00 | General |
209_212 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
213 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
214 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
215_218 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
219 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
220_223 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
224 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
FRONTSTAIRSFLR2UNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 0.01 | 0.57 | 92.91 | 1.00 | General |
REARSTAIRSFLR3UNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 0.01 | 0.57 | 92.91 | 1.00 | General |
CORRIDORFLR3 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
301 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
302_305 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
306_308 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.39 | 248.38 | 636.87 | 1.00 | General |
309_312 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
313 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
314 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
315_318 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
319 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
320_323 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
324 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
FRONTSTAIRSFLR3UNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 0.01 | 0.57 | 92.91 | 1.00 | General |
REARSTAIRSFLR4UNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 0.01 | 0.57 | 92.91 | 1.00 | General |
CORRIDORFLR4 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
401 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
402_405 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
406_408 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.39 | 248.38 | 636.87 | 1.00 | General |
409_412 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
413 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
414 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
415_418 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
419 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
420_423 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
424 PTAC SUPPLY FAN | Fan:OnOff | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
FRONTSTAIRSFLR4UNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 0.01 | 0.57 | 92.91 | 1.00 | General |
SAC_FRONTOFFICE SUPPLY FAN | Fan:ConstantVolume | 0.56 | 622.50 | 0.38 | 421.06 | 1120.11 | 1.00 | General |
SAC_FRONTLOUNGE SUPPLY FAN | Fan:ConstantVolume | 0.56 | 622.50 | 0.90 | 994.13 | 1107.16 | 1.00 | General |
SAC_MEETINGROOM SUPPLY FAN | Fan:OnOff | 0.56 | 622.50 | 0.43 | 476.72 | 1120.11 | 1.00 | General |
SAC_EXC_EMPLGE_RESTRM SUPPLY FAN | Fan:ConstantVolume | 0.56 | 622.50 | 0.85 | 938.19 | 1107.16 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
SHWSYSSHOWER PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.0002 | 8.11 | 45084.46 | 0.85 |
SHWSYSLAUNDRY PUMP | Pump:ConstantSpeed | Intermittent | 0.00 | 0.0001 | 0.00 | 0.00 | 0.30 |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SHWSYSSHOWER WATER HEATER | WaterHeater:Mixed | 1.14 | 87921.32 | 0.80 | 0.00 | 0.00 |
SHWSYSLAUNDRY WATER HEATER | WaterHeater:Mixed | 0.76 | 58614.21 | 0.81 | 0.80 | 0.51 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 10:15:39
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
FRONTLOUNGEFLR1 | 7366.77 | 8840.13 | 0.748 | 0.898 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:15:00 | 33.68 | 0.00543 |
RESTROOMFLR1 | 418.28 | 501.94 | 0.042 | 0.051 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 32.42 | 0.00543 |
MEETINGROOMFLR1 | 3489.11 | 4186.93 | 0.355 | 0.426 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 33.90 | 0.00543 |
GUESTROOM101 | 534.22 | 641.06 | 0.075 | 0.090 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:00:00 | 33.01 | 0.00543 |
GUESTROOM102 | 434.06 | 520.88 | 0.061 | 0.073 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:45:00 | 33.23 | 0.00543 |
GUESTROOM103 | 1018.41 | 1222.09 | 0.144 | 0.172 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 29.24 | 0.00543 |
GUESTROOM104 | 1153.07 | 1383.68 | 0.163 | 0.195 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 33.90 | 0.00543 |
GUESTROOM105 | 1518.38 | 1822.05 | 0.214 | 0.257 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.90 | 0.00543 |
EMPLOYEELOUNGEFLR1 | 5387.14 | 6464.57 | 0.547 | 0.657 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 33.90 | 0.00543 |
EXERCISECENTERFLR1 | 1146.78 | 1376.13 | 0.116 | 0.140 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 31.83 | 0.00543 |
FRONTOFFICEFLR1 | 3086.84 | 3704.20 | 0.313 | 0.376 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 33.90 | 0.00543 |
GUESTROOM201 | 738.44 | 886.13 | 0.104 | 0.125 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 33.90 | 0.00543 |
GUESTROOM202_205 | 4015.38 | 4818.46 | 0.567 | 0.680 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:00:00 | 33.01 | 0.00543 |
GUESTROOM206_208 | 3258.09 | 3909.71 | 0.460 | 0.552 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:45:00 | 33.23 | 0.00543 |
GUESTROOM209_212 | 3829.57 | 4595.49 | 0.540 | 0.648 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:00:00 | 33.01 | 0.00543 |
GUESTROOM213 | 1095.69 | 1314.82 | 0.155 | 0.186 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 29.24 | 0.00543 |
GUESTROOM214 | 1290.18 | 1548.22 | 0.182 | 0.218 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 33.90 | 0.00543 |
GUESTROOM215_218 | 9547.90 | 11457.48 | 1.347 | 1.617 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 33.90 | 0.00543 |
GUESTROOM219 | 5441.38 | 6529.66 | 0.768 | 0.921 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 33.90 | 0.00543 |
GUESTROOM220_223 | 4489.35 | 5387.23 | 0.633 | 0.760 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 33.90 | 0.00543 |
GUESTROOM224 | 1282.53 | 1539.03 | 0.181 | 0.217 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 33.90 | 0.00543 |
GUESTROOM301 | 564.71 | 677.66 | 0.080 | 0.096 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:15:00 | 33.68 | 0.00543 |
GUESTROOM302_305 | 1472.02 | 1766.42 | 0.208 | 0.249 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 29.79 | 0.00543 |
GUESTROOM306_308 | 1295.56 | 1554.68 | 0.183 | 0.219 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 29.79 | 0.00543 |
GUESTROOM309_312 | 3811.20 | 4573.44 | 0.538 | 0.645 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 29.79 | 0.00543 |
GUESTROOM313 | 601.22 | 721.47 | 0.085 | 0.102 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:45:00 | 28.68 | 0.00543 |
GUESTROOM314 | 1209.97 | 1451.96 | 0.171 | 0.205 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 33.90 | 0.00543 |
GUESTROOM315_318 | 4913.30 | 5895.96 | 0.693 | 0.832 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 33.90 | 0.00543 |
GUESTROOM319 | 1093.83 | 1312.60 | 0.154 | 0.185 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 33.90 | 0.00543 |
GUESTROOM320_323 | 4291.66 | 5149.99 | 0.606 | 0.727 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 33.90 | 0.00543 |
GUESTROOM324 | 713.25 | 855.89 | 0.101 | 0.121 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 33.90 | 0.00543 |
GUESTROOM401 | 1434.81 | 1721.77 | 0.202 | 0.243 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 33.90 | 0.00543 |
GUESTROOM402_405 | 2370.47 | 2844.56 | 0.334 | 0.401 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 33.90 | 0.00543 |
GUESTROOM406_408 | 2031.13 | 2437.35 | 0.287 | 0.344 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 33.90 | 0.00543 |
GUESTROOM409_412 | 5026.63 | 6031.95 | 0.709 | 0.851 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 33.90 | 0.00543 |
GUESTROOM413 | 886.46 | 1063.75 | 0.125 | 0.150 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:15:00 | 33.68 | 0.00543 |
GUESTROOM414 | 1049.57 | 1259.48 | 0.148 | 0.178 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 33.90 | 0.00543 |
GUESTROOM415_418 | 5744.38 | 6893.25 | 0.811 | 0.973 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 33.90 | 0.00543 |
GUESTROOM419 | 1585.76 | 1902.91 | 0.224 | 0.269 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.90 | 0.00543 |
GUESTROOM420_423 | 5706.34 | 6847.60 | 0.805 | 0.966 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 33.90 | 0.00543 |
GUESTROOM424 | 1605.15 | 1926.18 | 0.226 | 0.272 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 33.90 | 0.00543 |
REARSTAIRSFLR1 | 0.00 | 0.00 | 0.000 | 0.006 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 33.90 | 0.00543 | |
CORRIDORFLR1 | 14816.86 | 17780.24 | 1.503 | 1.803 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 30.35 | 0.00543 |
FRONTSTAIRSFLR1 | 0.00 | 0.00 | 0.000 | 0.006 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 33.90 | 0.00543 | |
REARSTAIRSFLR2 | 0.00 | 0.00 | 0.000 | 0.006 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 33.90 | 0.00543 | |
CORRIDORFLR2 | 2690.47 | 3228.57 | 0.273 | 0.328 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 31.83 | 0.00543 |
FRONTSTAIRSFLR2 | 0.00 | 0.00 | 0.000 | 0.006 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 33.90 | 0.00543 | |
REARSTAIRSFLR3 | 0.00 | 0.00 | 0.000 | 0.006 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 33.90 | 0.00543 | |
CORRIDORFLR3 | 1290.52 | 1548.63 | 0.131 | 0.157 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 31.46 | 0.00543 |
FRONTSTAIRSFLR3 | 0.00 | 0.00 | 0.000 | 0.006 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 33.90 | 0.00543 | |
REARSTAIRSFLR4 | 0.00 | 0.00 | 0.000 | 0.006 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 33.90 | 0.00543 | |
CORRIDORFLR4 | 2327.41 | 2792.89 | 0.236 | 0.283 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:15:00 | 33.68 | 0.00543 |
FRONTSTAIRSFLR4 | 0.00 | 0.00 | 0.000 | 0.006 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 33.90 | 0.00543 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
FRONTLOUNGEFLR1 | 1811.44 | 2173.73 | 0.063 | 0.236 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 07:15:00 | -17.90 | 0.00096 |
RESTROOMFLR1 | 124.74 | 149.69 | 0.004 | 0.005 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 07:30:00 | -17.90 | 0.00096 |
MEETINGROOMFLR1 | 637.34 | 764.81 | 0.022 | 0.126 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 07:00:00 | -17.90 | 0.00096 |
GUESTROOM101 | 269.51 | 323.41 | 0.009 | 0.013 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 07:45:00 | -17.90 | 0.00096 |
GUESTROOM102 | 314.08 | 376.90 | 0.011 | 0.013 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 07:30:00 | -17.90 | 0.00096 |
GUESTROOM103 | 533.91 | 640.70 | 0.019 | 0.022 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 07:30:00 | -17.90 | 0.00096 |
GUESTROOM104 | 532.18 | 638.61 | 0.018 | 0.022 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 07:45:00 | -17.90 | 0.00096 |
GUESTROOM105 | 319.21 | 383.05 | 0.011 | 0.013 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:30:00 | -17.90 | 0.00096 |
EMPLOYEELOUNGEFLR1 | 297.17 | 356.60 | 0.010 | 0.051 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -17.90 | 0.00096 |
EXERCISECENTERFLR1 | 201.43 | 241.72 | 0.007 | 0.043 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 06:00:00 | -17.90 | 0.00096 |
FRONTOFFICEFLR1 | 1159.83 | 1391.79 | 0.040 | 0.056 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 06:30:00 | -17.90 | 0.00096 |
GUESTROOM201 | 517.84 | 621.40 | 0.018 | 0.022 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 10:45:00 | -17.90 | 0.00096 |
GUESTROOM202_205 | 1085.28 | 1302.33 | 0.038 | 0.054 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 10:30:00 | -17.90 | 0.00096 |
GUESTROOM206_208 | 852.32 | 1022.78 | 0.030 | 0.043 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -17.90 | 0.00096 |
GUESTROOM209_212 | 996.95 | 1196.34 | 0.035 | 0.054 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:15:00 | -17.90 | 0.00096 |
GUESTROOM213 | 564.98 | 677.97 | 0.020 | 0.024 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 11:00:00 | -17.90 | 0.00096 |
GUESTROOM214 | 537.39 | 644.87 | 0.019 | 0.022 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 10:15:00 | -17.90 | 0.00096 |
GUESTROOM215_218 | 1008.60 | 1210.32 | 0.035 | 0.054 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:15:00 | -17.90 | 0.00096 |
GUESTROOM219 | 246.19 | 295.43 | 0.009 | 0.013 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:15:00 | -17.90 | 0.00096 |
GUESTROOM220_223 | 970.32 | 1164.38 | 0.034 | 0.054 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:15:00 | -17.90 | 0.00096 |
GUESTROOM224 | 460.10 | 552.12 | 0.016 | 0.019 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:15:00 | -17.90 | 0.00096 |
GUESTROOM301 | 563.93 | 676.72 | 0.020 | 0.024 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 17:30:00 | -17.90 | 0.00096 |
GUESTROOM302_305 | 1226.77 | 1472.13 | 0.043 | 0.054 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 17:00:00 | -17.90 | 0.00096 |
GUESTROOM306_308 | 1043.53 | 1252.24 | 0.036 | 0.043 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 13:15:00 | -17.90 | 0.00096 |
GUESTROOM309_312 | 1222.37 | 1466.84 | 0.042 | 0.054 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 13:45:00 | -17.90 | 0.00096 |
GUESTROOM313 | 649.70 | 779.64 | 0.023 | 0.027 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 22:30:00 | -17.90 | 0.00096 |
GUESTROOM314 | 613.60 | 736.32 | 0.021 | 0.026 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 15:30:00 | -17.90 | 0.00096 |
GUESTROOM315_318 | 1220.68 | 1464.81 | 0.042 | 0.054 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 13:00:00 | -17.90 | 0.00096 |
GUESTROOM319 | 336.57 | 403.89 | 0.012 | 0.014 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 13:00:00 | -17.90 | 0.00096 |
GUESTROOM320_323 | 1181.15 | 1417.38 | 0.041 | 0.054 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 13:00:00 | -17.90 | 0.00096 |
GUESTROOM324 | 545.29 | 654.34 | 0.019 | 0.023 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 19:15:00 | -17.90 | 0.00096 |
GUESTROOM401 | 837.66 | 1005.19 | 0.029 | 0.035 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 22:00:00 | -17.90 | 0.00096 |
GUESTROOM402_405 | 2192.70 | 2631.24 | 0.076 | 0.091 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 21:15:00 | -17.90 | 0.00096 |
GUESTROOM406_408 | 1845.48 | 2214.58 | 0.064 | 0.077 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 18:30:00 | -17.90 | 0.00096 |
GUESTROOM409_412 | 2201.61 | 2641.94 | 0.076 | 0.092 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 19:15:00 | -17.90 | 0.00096 |
GUESTROOM413 | 969.68 | 1163.62 | 0.034 | 0.040 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 23:30:00 | -17.90 | 0.00096 |
GUESTROOM414 | 931.77 | 1118.12 | 0.032 | 0.039 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 21:30:00 | -17.90 | 0.00096 |
GUESTROOM415_418 | 2198.59 | 2638.31 | 0.076 | 0.092 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 17:00:00 | -17.90 | 0.00096 |
GUESTROOM419 | 647.15 | 776.58 | 0.022 | 0.027 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 17:45:00 | -17.90 | 0.00096 |
GUESTROOM420_423 | 2158.50 | 2590.20 | 0.075 | 0.090 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 19:00:00 | -17.90 | 0.00096 |
GUESTROOM424 | 863.41 | 1036.09 | 0.030 | 0.036 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 23:30:00 | -17.90 | 0.00096 |
REARSTAIRSFLR1 | 0.00 | 0.00 | 0.000 | 0.006 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | -17.90 | 0.00096 | |
CORRIDORFLR1 | 19505.97 | 23407.16 | 0.677 | 0.812 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:15:00 | -17.90 | 0.00096 |
FRONTSTAIRSFLR1 | 0.00 | 0.00 | 0.000 | 0.006 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | -17.90 | 0.00096 | |
REARSTAIRSFLR2 | 0.00 | 0.00 | 0.000 | 0.006 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | -17.90 | 0.00096 | |
CORRIDORFLR2 | 671.63 | 805.96 | 0.023 | 0.038 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 09:45:00 | -17.90 | 0.00096 |
FRONTSTAIRSFLR2 | 0.00 | 0.00 | 0.000 | 0.006 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | -17.90 | 0.00096 | |
REARSTAIRSFLR3 | 0.00 | 0.00 | 0.000 | 0.006 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | -17.90 | 0.00096 | |
CORRIDORFLR3 | 936.42 | 1123.71 | 0.033 | 0.039 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 13:30:00 | -17.90 | 0.00096 |
FRONTSTAIRSFLR3 | 0.00 | 0.00 | 0.000 | 0.006 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | -17.90 | 0.00096 | |
REARSTAIRSFLR4 | 0.00 | 0.00 | 0.000 | 0.006 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | -17.90 | 0.00096 | |
CORRIDORFLR4 | 2177.65 | 2613.18 | 0.076 | 0.091 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 23:30:00 | -17.90 | 0.00096 |
FRONTSTAIRSFLR4 | 54.12 | 64.95 | 0.001 | 0.006 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 23:30:00 | -17.90 | 0.00096 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
SAC_FRONTOFFICE | 0.38 | 0.38 | 0.06 | 0.06 |
SAC_FRONTLOUNGE | 0.90 | 0.90 | 0.24 | 0.24 |
SAC_MEETINGROOM | 0.43 | 0.43 | 0.13 | 0.13 |
SAC_EXC_EMPLGE_RESTRM | 0.85 | 0.85 | 0.10 | 0.10 |
Report: System Summary
For: Entire Facility
Timestamp: 2018-10-19 10:15:39
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
FRONTLOUNGEFLR1 | 1407.00 | 7183.50 | 1058.50 |
RESTROOMFLR1 | 310.25 | 7967.50 | 262.25 |
MEETINGROOMFLR1 | 414.50 | 3479.25 | 157.75 |
GUESTROOM101 | 0.00 | 0.00 | 0.00 |
GUESTROOM102 | 0.00 | 0.00 | 0.00 |
GUESTROOM103 | 1213.75 | 8760.00 | 1213.75 |
GUESTROOM104 | 368.25 | 8760.00 | 368.25 |
GUESTROOM105 | 28.75 | 8664.50 | 28.75 |
EMPLOYEELOUNGEFLR1 | 2769.25 | 2274.25 | 227.00 |
EXERCISECENTERFLR1 | 915.00 | 2831.25 | 23.50 |
FRONTOFFICEFLR1 | 659.00 | 6646.25 | 276.00 |
GUESTROOM201 | 0.00 | 0.00 | 0.00 |
GUESTROOM202_205 | 640.25 | 8708.75 | 640.25 |
GUESTROOM206_208 | 526.50 | 8717.25 | 526.50 |
GUESTROOM209_212 | 455.00 | 8749.50 | 455.00 |
GUESTROOM213 | 1396.50 | 8760.00 | 1396.50 |
GUESTROOM214 | 308.00 | 8715.50 | 308.00 |
GUESTROOM215_218 | 0.00 | 0.00 | 0.00 |
GUESTROOM219 | 3998.50 | 4107.50 | 449.00 |
GUESTROOM220_223 | 99.00 | 8602.50 | 99.00 |
GUESTROOM224 | 305.75 | 8692.75 | 305.75 |
GUESTROOM301 | 0.00 | 0.00 | 0.00 |
GUESTROOM302_305 | 0.00 | 0.00 | 0.00 |
GUESTROOM306_308 | 0.00 | 0.00 | 0.00 |
GUESTROOM309_312 | 727.00 | 8748.00 | 727.00 |
GUESTROOM313 | 0.00 | 0.00 | 0.00 |
GUESTROOM314 | 688.25 | 8718.50 | 688.25 |
GUESTROOM315_318 | 108.75 | 8430.75 | 108.75 |
GUESTROOM319 | 0.00 | 0.00 | 0.00 |
GUESTROOM320_323 | 240.25 | 8661.00 | 240.25 |
GUESTROOM324 | 0.00 | 0.00 | 0.00 |
GUESTROOM401 | 3104.50 | 8109.50 | 3067.25 |
GUESTROOM402_405 | 0.00 | 0.00 | 0.00 |
GUESTROOM406_408 | 0.00 | 0.00 | 0.00 |
GUESTROOM409_412 | 1613.25 | 8023.25 | 1530.50 |
GUESTROOM413 | 0.00 | 0.00 | 0.00 |
GUESTROOM414 | 0.00 | 0.00 | 0.00 |
GUESTROOM415_418 | 1013.00 | 7370.75 | 683.25 |
GUESTROOM419 | 768.00 | 7724.75 | 683.75 |
GUESTROOM420_423 | 1042.25 | 7430.50 | 743.75 |
GUESTROOM424 | 1433.25 | 7938.50 | 1360.00 |
REARSTAIRSFLR1 | 0.00 | 0.00 | 0.00 |
CORRIDORFLR1 | 0.00 | 0.00 | 0.00 |
FRONTSTAIRSFLR1 | 0.00 | 0.00 | 0.00 |
REARSTAIRSFLR2 | 0.00 | 0.00 | 0.00 |
CORRIDORFLR2 | 0.00 | 0.00 | 0.00 |
FRONTSTAIRSFLR2 | 0.00 | 0.00 | 0.00 |
REARSTAIRSFLR3 | 0.00 | 0.00 | 0.00 |
CORRIDORFLR3 | 0.00 | 0.00 | 0.00 |
FRONTSTAIRSFLR3 | 0.00 | 0.00 | 0.00 |
REARSTAIRSFLR4 | 0.00 | 0.00 | 0.00 |
CORRIDORFLR4 | 0.00 | 0.00 | 0.00 |
FRONTSTAIRSFLR4 | 0.00 | 0.00 | 0.00 |
REARSTORAGEFLR1 | 0.00 | 0.00 | 0.00 |
MECHANICALROOMFLR1 | 0.00 | 0.00 | 0.00 |
LAUNDRYROOMFLR1 | 2920.00 | 2920.00 | 2920.00 |
ELEVATORCOREFLR1 | 0.00 | 0.00 | 0.00 |
FRONTSTORAGEFLR1 | 0.00 | 0.00 | 0.00 |
REARSTORAGEFLR2 | 0.00 | 0.00 | 0.00 |
ELEVATORCOREFLR2 | 0.00 | 0.00 | 0.00 |
FRONTSTORAGEFLR2 | 0.00 | 0.00 | 0.00 |
REARSTORAGEFLR3 | 0.00 | 0.00 | 0.00 |
ELEVATORCOREFLR3 | 0.00 | 0.00 | 0.00 |
FRONTSTORAGEFLR3 | 0.00 | 0.00 | 0.00 |
REARSTORAGEFLR4 | 0.00 | 0.00 | 0.00 |
ELEVATORCOREFLR4 | 0.00 | 0.00 | 0.00 |
FRONTSTORAGEFLR4 | 0.00 | 0.00 | 0.00 |
Facility | 7153.75 | 8760.00 | 5686.75 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
FRONTLOUNGEFLR1 | 0.50 | 0.00 | 0.50 | 0.00 |
RESTROOMFLR1 | 160.75 | 659.75 | 160.75 | 659.75 |
MEETINGROOMFLR1 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM101 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM102 | 0.25 | 0.00 | 0.00 | 0.00 |
GUESTROOM103 | 8.25 | 12.75 | 8.25 | 12.75 |
GUESTROOM104 | 3.75 | 21.25 | 3.75 | 21.25 |
GUESTROOM105 | 0.00 | 31.50 | 0.00 | 31.50 |
EMPLOYEELOUNGEFLR1 | 305.50 | 1149.75 | 236.50 | 591.75 |
EXERCISECENTERFLR1 | 0.75 | 0.00 | 0.00 | 0.00 |
FRONTOFFICEFLR1 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM201 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM202_205 | 5.75 | 0.50 | 5.75 | 0.50 |
GUESTROOM206_208 | 5.00 | 8.25 | 5.00 | 8.25 |
GUESTROOM209_212 | 5.00 | 0.25 | 5.00 | 0.25 |
GUESTROOM213 | 11.25 | 0.50 | 11.25 | 0.50 |
GUESTROOM214 | 2.75 | 6.50 | 2.75 | 6.50 |
GUESTROOM215_218 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM219 | 0.00 | 2723.75 | 0.00 | 2723.75 |
GUESTROOM220_223 | 0.50 | 1.50 | 0.50 | 1.50 |
GUESTROOM224 | 3.50 | 6.00 | 3.50 | 6.00 |
GUESTROOM301 | 0.25 | 0.00 | 0.00 | 0.00 |
GUESTROOM302_305 | 0.25 | 0.00 | 0.00 | 0.00 |
GUESTROOM306_308 | 0.50 | 0.00 | 0.00 | 0.00 |
GUESTROOM309_312 | 7.75 | 0.50 | 7.75 | 0.50 |
GUESTROOM313 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM314 | 5.50 | 5.25 | 5.50 | 5.25 |
GUESTROOM315_318 | 0.75 | 3.75 | 0.75 | 3.75 |
GUESTROOM319 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM320_323 | 2.50 | 1.00 | 2.50 | 1.00 |
GUESTROOM324 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM401 | 13.75 | 21.75 | 13.75 | 21.75 |
GUESTROOM402_405 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM406_408 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM409_412 | 11.25 | 11.00 | 11.25 | 11.00 |
GUESTROOM413 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM414 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM415_418 | 5.50 | 17.25 | 5.50 | 17.25 |
GUESTROOM419 | 5.25 | 25.25 | 5.25 | 25.25 |
GUESTROOM420_423 | 5.50 | 16.75 | 5.50 | 16.75 |
GUESTROOM424 | 5.50 | 24.75 | 5.50 | 24.75 |
REARSTAIRSFLR1 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDORFLR1 | 6.50 | 3054.50 | 0.00 | 0.00 |
FRONTSTAIRSFLR1 | 0.00 | 0.00 | 0.00 | 0.00 |
REARSTAIRSFLR2 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDORFLR2 | 0.00 | 54.75 | 0.00 | 0.00 |
FRONTSTAIRSFLR2 | 0.00 | 0.00 | 0.00 | 0.00 |
REARSTAIRSFLR3 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDORFLR3 | 0.00 | 0.00 | 0.00 | 0.00 |
FRONTSTAIRSFLR3 | 0.00 | 0.00 | 0.00 | 0.00 |
REARSTAIRSFLR4 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDORFLR4 | 0.00 | 282.25 | 0.00 | 0.00 |
FRONTSTAIRSFLR4 | 2.00 | 0.00 | 0.00 | 0.00 |
REARSTORAGEFLR1 | 0.00 | 0.00 | 0.00 | 0.00 |
MECHANICALROOMFLR1 | 0.00 | 0.00 | 0.00 | 0.00 |
LAUNDRYROOMFLR1 | 0.00 | 0.00 | 0.00 | 0.00 |
ELEVATORCOREFLR1 | 0.00 | 0.00 | 0.00 | 0.00 |
FRONTSTORAGEFLR1 | 0.00 | 0.00 | 0.00 | 0.00 |
REARSTORAGEFLR2 | 0.00 | 0.00 | 0.00 | 0.00 |
ELEVATORCOREFLR2 | 0.00 | 0.00 | 0.00 | 0.00 |
FRONTSTORAGEFLR2 | 0.00 | 0.00 | 0.00 | 0.00 |
REARSTORAGEFLR3 | 0.00 | 0.00 | 0.00 | 0.00 |
ELEVATORCOREFLR3 | 0.00 | 0.00 | 0.00 | 0.00 |
FRONTSTORAGEFLR3 | 0.00 | 0.00 | 0.00 | 0.00 |
REARSTORAGEFLR4 | 0.00 | 0.00 | 0.00 | 0.00 |
ELEVATORCOREFLR4 | 0.00 | 0.00 | 0.00 | 0.00 |
FRONTSTORAGEFLR4 | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 380.75 | 4763.50 | 337.25 | 3561.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2018-10-19 10:15:39
ZoneHVAC:UnitHeaterMaximum Supply Air Flow Rate [m3/s] | |
REARSTAIRSFLR1 UNITHEATER | 0.006116 |
MECHRM UNITHEATER | 0.000000 |
FRONTSTAIRSFLR1 UNITHEATER | 0.006114 |
REARSTAIRSFLR2 UNITHEATER | 0.006116 |
FRONTSTAIRSFLR2 UNITHEATER | 0.006114 |
REARSTAIRSFLR3 UNITHEATER | 0.006116 |
FRONTSTAIRSFLR3 UNITHEATER | 0.006114 |
REARSTAIRSFLR4 UNITHEATER | 0.006116 |
FRONTSTAIRSFLR4 UNITHEATER | 0.006114 |
Maximum Flow Rate [m3/s] | |
REARSTAIRSFLR1UNITHEATERFAN | 0.006116 |
MECHRMUNITHEATERFAN | 0.000000 |
FRONTSTAIRSFLR1UNITHEATERFAN | 0.006114 |
REARSTAIRSFLR2UNITHEATERFAN | 0.006116 |
FRONTSTAIRSFLR2UNITHEATERFAN | 0.006114 |
REARSTAIRSFLR3UNITHEATERFAN | 0.006116 |
FRONTSTAIRSFLR3UNITHEATERFAN | 0.006114 |
REARSTAIRSFLR4UNITHEATERFAN | 0.006116 |
FRONTSTAIRSFLR4UNITHEATERFAN | 0.006114 |
SAC_FRONTOFFICE SUPPLY FAN | 0.375911 |
SAC_FRONTLOUNGE SUPPLY FAN | 0.897909 |
SAC_EXC_EMPLGE_RESTRM SUPPLY FAN | 0.847382 |
Nominal Capacity [W] | |
REARSTAIRSFLR1UNITHEATERHEATINGCOIL | 260.88 |
CORRIDORFLR1 PTAC HEATING COIL | 25205.09 |
MECHRMUNITHEATERHEATINGCOIL | 0.000000 |
101 PTAC HEATING COIL | 911.88 |
102 PTAC HEATING COIL | 911.88 |
103 PTAC HEATING COIL | 1164.60 |
104 PTAC HEATING COIL | 1162.48 |
105 PTAC HEATING COIL | 911.81 |
FRONTSTAIRSFLR1UNITHEATERHEATINGCOIL | 260.82 |
REARSTAIRSFLR2UNITHEATERHEATINGCOIL | 260.88 |
CORRIDORFLR2 PTAC HEATING COIL | 2586.13 |
201 PTAC HEATING COIL | 1145.31 |
202_205 PTAC HEATING COIL | 3647.51 |
206_208 PTAC HEATING COIL | 2890.77 |
209_212 PTAC HEATING COIL | 3647.51 |
213 PTAC HEATING COIL | 1201.88 |
214 PTAC HEATING COIL | 1168.74 |
215_218 PTAC HEATING COIL | 3647.25 |
219 PTAC HEATING COIL | 911.81 |
220_223 PTAC HEATING COIL | 3647.25 |
224 PTAC HEATING COIL | 1075.99 |
FRONTSTAIRSFLR2UNITHEATERHEATINGCOIL | 260.82 |
REARSTAIRSFLR3UNITHEATERHEATINGCOIL | 260.88 |
CORRIDORFLR3 PTAC HEATING COIL | 2609.51 |
301 PTAC HEATING COIL | 1200.62 |
302_305 PTAC HEATING COIL | 3647.51 |
306_308 PTAC HEATING COIL | 2913.09 |
309_312 PTAC HEATING COIL | 3647.51 |
313 PTAC HEATING COIL | 1303.54 |
314 PTAC HEATING COIL | 1260.19 |
315_318 PTAC HEATING COIL | 3647.25 |
319 PTAC HEATING COIL | 927.76 |
320_323 PTAC HEATING COIL | 3647.25 |
324 PTAC HEATING COIL | 1178.21 |
FRONTSTAIRSFLR3UNITHEATERHEATINGCOIL | 260.82 |
REARSTAIRSFLR4UNITHEATERHEATINGCOIL | 260.88 |
CORRIDORFLR4 PTAC HEATING COIL | 4098.96 |
401 PTAC HEATING COIL | 1529.09 |
402_405 PTAC HEATING COIL | 4726.87 |
406_408 PTAC HEATING COIL | 3875.43 |
409_412 PTAC HEATING COIL | 4737.56 |
413 PTAC HEATING COIL | 1687.52 |
414 PTAC HEATING COIL | 1641.99 |
415_418 PTAC HEATING COIL | 4733.78 |
419 PTAC HEATING COIL | 1300.45 |
420_423 PTAC HEATING COIL | 4685.67 |
424 PTAC HEATING COIL | 1559.96 |
FRONTSTAIRSFLR4UNITHEATERHEATINGCOIL | 413.78 |
Rated Sensible Heat Ratio | Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity (gross) [W] | |
CORRIDORFLR1 PTAC COOLING COIL | 0.730484 | ||
101 PTAC COOLING COIL | 0.730484 | ||
102 PTAC COOLING COIL | 0.730484 | ||
103 PTAC COOLING COIL | 0.730484 | ||
104 PTAC COOLING COIL | 0.730484 | ||
105 PTAC COOLING COIL | 0.730484 | ||
CORRIDORFLR2 PTAC COOLING COIL | 0.730484 | ||
201 PTAC COOLING COIL | 0.730484 | ||
202_205 PTAC COOLING COIL | 0.730484 | ||
206_208 PTAC COOLING COIL | 0.730484 | ||
209_212 PTAC COOLING COIL | 0.730484 | ||
213 PTAC COOLING COIL | 0.730484 | ||
214 PTAC COOLING COIL | 0.730484 | ||
215_218 PTAC COOLING COIL | 0.730484 | ||
219 PTAC COOLING COIL | 0.730484 | ||
220_223 PTAC COOLING COIL | 0.730484 | ||
224 PTAC COOLING COIL | 0.730484 | ||
CORRIDORFLR3 PTAC COOLING COIL | 0.730484 | ||
301 PTAC COOLING COIL | 0.730484 | ||
302_305 PTAC COOLING COIL | 0.730484 | ||
306_308 PTAC COOLING COIL | 0.730484 | ||
309_312 PTAC COOLING COIL | 0.730484 | ||
313 PTAC COOLING COIL | 0.730484 | ||
314 PTAC COOLING COIL | 0.730484 | ||
315_318 PTAC COOLING COIL | 0.730484 | ||
319 PTAC COOLING COIL | 0.730484 | ||
320_323 PTAC COOLING COIL | 0.730484 | ||
324 PTAC COOLING COIL | 0.730484 | ||
CORRIDORFLR4 PTAC COOLING COIL | 0.730484 | ||
401 PTAC COOLING COIL | 0.730484 | ||
402_405 PTAC COOLING COIL | 0.730484 | ||
406_408 PTAC COOLING COIL | 0.730484 | ||
409_412 PTAC COOLING COIL | 0.730484 | ||
413 PTAC COOLING COIL | 0.730484 | ||
414 PTAC COOLING COIL | 0.730484 | ||
415_418 PTAC COOLING COIL | 0.730484 | ||
419 PTAC COOLING COIL | 0.730484 | ||
420_423 PTAC COOLING COIL | 0.730484 | ||
424 PTAC COOLING COIL | 0.730484 | ||
SAC_FRONTOFFICE COOLING COIL | 0.798655 | 0.375911 | 6222.67 |
SAC_FRONTLOUNGE COOLING COIL | 0.780924 | 0.897909 | 15616.75 |
SAC_MEETINGROOM COOLING COIL | 0.745379 | 0.425599 | 8239.09 |
SAC_EXC_EMPLGE_RESTRM COOLING COIL | 0.798655 | 0.847382 | 14027.18 |
Maximum Air Flow Rate [m3/s] | |
FRONTLOUNGEFLR1 DIRECT AIR | 0.897909 |
RESTROOMFLR1 DIRECT AIR | 0.050929 |
MEETINGROOMFLR1 DIRECT AIR | 0.425599 |
EMPLOYEELOUNGEFLR1 DIRECT AIR | 0.656740 |
EXERCISECENTERFLR1 DIRECT AIR | 0.139713 |
FRONTOFFICEFLR1 DIRECT AIR | 0.375911 |
Maximum Flow Rate [m3/s] | |
SAC_FRONTOFFICE MAIN BRANCH | 0.375911 |
SAC_FRONTLOUNGE MAIN BRANCH | 0.897909 |
SAC_MEETINGROOM MAIN BRANCH | 0.425599 |
SAC_EXC_EMPLGE_RESTRM MAIN BRANCH | 0.847382 |
Design Supply Air Flow Rate [m3/s] | |
SAC_FRONTOFFICE | 0.375911 |
SAC_FRONTLOUNGE | 0.897909 |
SAC_MEETINGROOM | 0.425599 |
SAC_EXC_EMPLGE_RESTRM | 0.847382 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
SAC_FRONTOFFICE OA CONTROLLER | 0.375911 | 0.056300 |
SAC_FRONTLOUNGE OA CONTROLLER | 0.897909 | 0.235982 |
SAC_MEETINGROOM OA CONTROLLER | 0.425599 | 0.126367 |
SAC_EXC_EMPLGE_RESTRM OA CONTROLLER | 0.847382 | 0.094386 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
SAC_FRONTOFFICE | 0.375911 | 0.375911 | 0.375911 | 0.375911 | 3754.70 | 6222.67 | 1.00 |
SAC_FRONTLOUNGE | 0.897909 | 0.897909 | 0.897909 | 0.897909 | 15737.76 | 15616.75 | 1.00 |
SAC_MEETINGROOM | 0.425599 | 0.425599 | 0.425599 | 0.425599 | 8427.45 | 8239.09 | 1.00 |
SAC_EXC_EMPLGE_RESTRM | 0.847382 | 0.847382 | 0.847382 | 0.847382 | 6442.16 | 14027.18 | 0.164876 |
Nominal Capacity [W] | |
SAC_FRONTOFFICE HEATING COIL | 3754.70 |
SAC_FRONTLOUNGE HEATING COIL | 15737.76 |
SAC_MEETINGROOM HEATING COIL | 8427.45 |
SAC_EXC_EMPLGE_RESTRM HEATING COIL | 6442.16 |
Maximum Flow Rate [m3/s] | |
SAC_MEETINGROOM SUPPLY FAN | 0.425599 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
SHWSYSSHOWER | 0.000180 | 0.202443 |
SHWSYSLAUNDRY | 0.000129 | 0.145496 |
Use Side Design Flow Rate [m3/s] | |
SHWSYSSHOWER WATER HEATER | 0.000180 |
SHWSYSLAUNDRY WATER HEATER | 0.000129 |
Rated Flow Rate [m3/s] | Rated Power Consumption [W] | |
SHWSYSSHOWER PUMP | 0.000180 | 8.11 |
SHWSYSLAUNDRY PUMP | 0.000129 | 0.000001 |
Report: MONTHLY INDOOR TEMP
For: REARSTAIRSFLR1
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.41 | 0.85 |
February | 18.34 | -0.2 |
March | 19.10 | 4.82 |
April | 19.16 | 6.08 |
May | 21.56 | 13.74 |
June | 23.91 | 22.16 |
July | 24.00 | 22.71 |
August | 23.87 | 21.74 |
September | 23.06 | 18.54 |
October | 20.33 | 7.12 |
November | 19.58 | 3.03 |
December | 17.62 | -1.0 |
Annual Sum or Average | 20.84 | 10.02 |
Minimum of Months | 17.62 | -1.0 |
Maximum of Months | 24.00 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: CORRIDORFLR1
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.07 | 0.85 |
February | 22.84 | -0.2 |
March | 23.35 | 4.82 |
April | 23.47 | 6.08 |
May | 24.48 | 13.74 |
June | 25.92 | 22.16 |
July | 25.99 | 22.71 |
August | 25.82 | 21.74 |
September | 25.27 | 18.54 |
October | 23.72 | 7.12 |
November | 23.27 | 3.03 |
December | 22.75 | -1.0 |
Annual Sum or Average | 24.17 | 10.02 |
Minimum of Months | 22.75 | -1.0 |
Maximum of Months | 25.99 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: REARSTORAGEFLR1
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 18.41 | 0.85 |
February | 17.50 | -0.2 |
March | 18.41 | 4.82 |
April | 18.65 | 6.08 |
May | 21.08 | 13.74 |
June | 23.42 | 22.16 |
July | 23.49 | 22.71 |
August | 23.24 | 21.74 |
September | 22.36 | 18.54 |
October | 19.56 | 7.12 |
November | 18.64 | 3.03 |
December | 16.86 | -1.0 |
Annual Sum or Average | 20.15 | 10.02 |
Minimum of Months | 16.86 | -1.0 |
Maximum of Months | 23.49 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: FRONTLOUNGEFLR1
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.46 | 0.85 |
February | 21.36 | -0.2 |
March | 21.83 | 4.82 |
April | 21.92 | 6.08 |
May | 22.93 | 13.74 |
June | 23.76 | 22.16 |
July | 23.80 | 22.71 |
August | 23.80 | 21.74 |
September | 23.45 | 18.54 |
October | 22.14 | 7.12 |
November | 21.61 | 3.03 |
December | 21.47 | -1.0 |
Annual Sum or Average | 22.47 | 10.02 |
Minimum of Months | 21.36 | -1.0 |
Maximum of Months | 23.80 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: RESTROOMFLR1
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.85 | 0.85 |
February | 21.74 | -0.2 |
March | 22.16 | 4.82 |
April | 22.34 | 6.08 |
May | 23.05 | 13.74 |
June | 23.65 | 22.16 |
July | 23.68 | 22.71 |
August | 23.59 | 21.74 |
September | 23.34 | 18.54 |
October | 22.46 | 7.12 |
November | 22.04 | 3.03 |
December | 21.65 | -1.0 |
Annual Sum or Average | 22.63 | 10.02 |
Minimum of Months | 21.65 | -1.0 |
Maximum of Months | 23.68 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: MEETINGROOMFLR1
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | 0.85 |
February | 21.56 | -0.2 |
March | 22.10 | 4.82 |
April | 22.25 | 6.08 |
May | 23.33 | 13.74 |
June | 23.77 | 22.16 |
July | 23.80 | 22.71 |
August | 23.77 | 21.74 |
September | 23.61 | 18.54 |
October | 22.57 | 7.12 |
November | 21.95 | 3.03 |
December | 21.62 | -1.0 |
Annual Sum or Average | 22.68 | 10.02 |
Minimum of Months | 21.56 | -1.0 |
Maximum of Months | 23.80 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: MECHANICALROOMFLR1
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.16 | 0.85 |
February | 23.97 | -0.2 |
March | 24.47 | 4.82 |
April | 24.69 | 6.08 |
May | 25.67 | 13.74 |
June | 26.46 | 22.16 |
July | 26.57 | 22.71 |
August | 26.49 | 21.74 |
September | 26.19 | 18.54 |
October | 25.06 | 7.12 |
November | 24.47 | 3.03 |
December | 23.94 | -1.0 |
Annual Sum or Average | 25.18 | 10.02 |
Minimum of Months | 23.94 | -1.0 |
Maximum of Months | 26.57 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM101
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.79 | 0.85 |
February | 19.60 | -0.2 |
March | 20.38 | 4.82 |
April | 20.65 | 6.08 |
May | 22.24 | 13.74 |
June | 23.19 | 22.16 |
July | 23.24 | 22.71 |
August | 23.20 | 21.74 |
September | 22.87 | 18.54 |
October | 21.06 | 7.12 |
November | 20.17 | 3.03 |
December | 19.68 | -1.0 |
Annual Sum or Average | 21.35 | 10.02 |
Minimum of Months | 19.60 | -1.0 |
Maximum of Months | 23.24 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM102
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.55 | 0.85 |
February | 19.39 | -0.2 |
March | 20.09 | 4.82 |
April | 20.34 | 6.08 |
May | 21.95 | 13.74 |
June | 23.06 | 22.16 |
July | 23.14 | 22.71 |
August | 23.06 | 21.74 |
September | 22.67 | 18.54 |
October | 20.74 | 7.12 |
November | 19.88 | 3.03 |
December | 19.46 | -1.0 |
Annual Sum or Average | 21.12 | 10.02 |
Minimum of Months | 19.39 | -1.0 |
Maximum of Months | 23.14 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM103
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.91 | 0.85 |
February | 20.82 | -0.2 |
March | 21.05 | 4.82 |
April | 21.11 | 6.08 |
May | 21.61 | 13.74 |
June | 21.75 | 22.16 |
July | 21.75 | 22.71 |
August | 21.75 | 21.74 |
September | 21.71 | 18.54 |
October | 21.25 | 7.12 |
November | 21.03 | 3.03 |
December | 20.85 | -1.0 |
Annual Sum or Average | 21.30 | 10.02 |
Minimum of Months | 20.82 | -1.0 |
Maximum of Months | 21.75 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM104
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.40 | 0.85 |
February | 21.27 | -0.2 |
March | 21.33 | 4.82 |
April | 21.32 | 6.08 |
May | 21.68 | 13.74 |
June | 21.75 | 22.16 |
July | 21.75 | 22.71 |
August | 21.75 | 21.74 |
September | 21.74 | 18.54 |
October | 21.47 | 7.12 |
November | 21.45 | 3.03 |
December | 21.24 | -1.0 |
Annual Sum or Average | 21.51 | 10.02 |
Minimum of Months | 21.24 | -1.0 |
Maximum of Months | 21.75 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM105
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.62 | 0.85 |
February | 21.56 | -0.2 |
March | 21.59 | 4.82 |
April | 21.58 | 6.08 |
May | 21.74 | 13.74 |
June | 21.75 | 22.16 |
July | 21.75 | 22.71 |
August | 21.75 | 21.74 |
September | 21.75 | 18.54 |
October | 21.62 | 7.12 |
November | 21.64 | 3.03 |
December | 21.51 | -1.0 |
Annual Sum or Average | 21.66 | 10.02 |
Minimum of Months | 21.51 | -1.0 |
Maximum of Months | 21.75 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: EMPLOYEELOUNGEFLR1
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.11 | 0.85 |
February | 22.16 | -0.2 |
March | 22.34 | 4.82 |
April | 22.47 | 6.08 |
May | 22.59 | 13.74 |
June | 22.44 | 22.16 |
July | 22.38 | 22.71 |
August | 22.38 | 21.74 |
September | 22.39 | 18.54 |
October | 22.30 | 7.12 |
November | 22.18 | 3.03 |
December | 22.06 | -1.0 |
Annual Sum or Average | 22.32 | 10.02 |
Minimum of Months | 22.06 | -1.0 |
Maximum of Months | 22.59 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: LAUNDRYROOMFLR1
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 51.67 | 0.85 |
February | 51.36 | -0.2 |
March | 51.56 | 4.82 |
April | 51.45 | 6.08 |
May | 52.18 | 13.74 |
June | 52.92 | 22.16 |
July | 53.01 | 22.71 |
August | 53.07 | 21.74 |
September | 52.90 | 18.54 |
October | 52.07 | 7.12 |
November | 51.80 | 3.03 |
December | 51.18 | -1.0 |
Annual Sum or Average | 52.10 | 10.02 |
Minimum of Months | 51.18 | -1.0 |
Maximum of Months | 53.07 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: ELEVATORCOREFLR1
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 68.96 | 0.85 |
February | 68.48 | -0.2 |
March | 68.75 | 4.82 |
April | 68.67 | 6.08 |
May | 69.69 | 13.74 |
June | 70.64 | 22.16 |
July | 70.73 | 22.71 |
August | 70.74 | 21.74 |
September | 70.42 | 18.54 |
October | 69.37 | 7.12 |
November | 69.05 | 3.03 |
December | 68.24 | -1.0 |
Annual Sum or Average | 69.48 | 10.02 |
Minimum of Months | 68.24 | -1.0 |
Maximum of Months | 70.74 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: EXERCISECENTERFLR1
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.02 | 0.85 |
February | 22.96 | -0.2 |
March | 23.18 | 4.82 |
April | 23.25 | 6.08 |
May | 23.64 | 13.74 |
June | 23.88 | 22.16 |
July | 23.88 | 22.71 |
August | 23.89 | 21.74 |
September | 23.82 | 18.54 |
October | 23.36 | 7.12 |
November | 23.14 | 3.03 |
December | 22.85 | -1.0 |
Annual Sum or Average | 23.41 | 10.02 |
Minimum of Months | 22.85 | -1.0 |
Maximum of Months | 23.89 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: FRONTOFFICEFLR1
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.52 | 0.85 |
February | 22.35 | -0.2 |
March | 22.71 | 4.82 |
April | 22.79 | 6.08 |
May | 23.59 | 13.74 |
June | 23.88 | 22.16 |
July | 23.89 | 22.71 |
August | 23.89 | 21.74 |
September | 23.81 | 18.54 |
October | 23.07 | 7.12 |
November | 22.71 | 3.03 |
December | 22.30 | -1.0 |
Annual Sum or Average | 23.13 | 10.02 |
Minimum of Months | 22.30 | -1.0 |
Maximum of Months | 23.89 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: FRONTSTAIRSFLR1
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 18.97 | 0.85 |
February | 17.74 | -0.2 |
March | 18.73 | 4.82 |
April | 18.83 | 6.08 |
May | 21.59 | 13.74 |
June | 24.37 | 22.16 |
July | 24.58 | 22.71 |
August | 24.41 | 21.74 |
September | 23.44 | 18.54 |
October | 20.18 | 7.12 |
November | 19.18 | 3.03 |
December | 16.94 | -1.0 |
Annual Sum or Average | 20.76 | 10.02 |
Minimum of Months | 16.94 | -1.0 |
Maximum of Months | 24.58 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: FRONTSTORAGEFLR1
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.07 | 0.85 |
February | 20.39 | -0.2 |
March | 20.98 | 4.82 |
April | 21.03 | 6.08 |
May | 22.66 | 13.74 |
June | 24.20 | 22.16 |
July | 24.35 | 22.71 |
August | 24.29 | 21.74 |
September | 23.81 | 18.54 |
October | 21.95 | 7.12 |
November | 21.27 | 3.03 |
December | 19.98 | -1.0 |
Annual Sum or Average | 22.18 | 10.02 |
Minimum of Months | 19.98 | -1.0 |
Maximum of Months | 24.35 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: REARSTAIRSFLR2
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.40 | 0.85 |
February | 18.02 | -0.2 |
March | 18.93 | 4.82 |
April | 19.05 | 6.08 |
May | 21.96 | 13.74 |
June | 24.71 | 22.16 |
July | 24.79 | 22.71 |
August | 24.60 | 21.74 |
September | 23.64 | 18.54 |
October | 20.41 | 7.12 |
November | 19.49 | 3.03 |
December | 17.08 | -1.0 |
Annual Sum or Average | 21.02 | 10.02 |
Minimum of Months | 17.08 | -1.0 |
Maximum of Months | 24.79 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: CORRIDORFLR2
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.44 | 0.85 |
February | 22.14 | -0.2 |
March | 22.64 | 4.82 |
April | 22.82 | 6.08 |
May | 23.76 | 13.74 |
June | 23.91 | 22.16 |
July | 23.90 | 22.71 |
August | 23.90 | 21.74 |
September | 23.85 | 18.54 |
October | 23.15 | 7.12 |
November | 22.65 | 3.03 |
December | 22.11 | -1.0 |
Annual Sum or Average | 23.11 | 10.02 |
Minimum of Months | 22.11 | -1.0 |
Maximum of Months | 23.91 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: REARSTORAGEFLR2
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 17.56 | 0.85 |
February | 16.39 | -0.2 |
March | 17.59 | 4.82 |
April | 17.93 | 6.08 |
May | 21.08 | 13.74 |
June | 24.02 | 22.16 |
July | 24.09 | 22.71 |
August | 23.76 | 21.74 |
September | 22.64 | 18.54 |
October | 19.02 | 7.12 |
November | 17.79 | 3.03 |
December | 15.54 | -1.0 |
Annual Sum or Average | 19.80 | 10.02 |
Minimum of Months | 15.54 | -1.0 |
Maximum of Months | 24.09 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM201
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.26 | 0.85 |
February | 19.21 | -0.2 |
March | 19.94 | 4.82 |
April | 20.13 | 6.08 |
May | 22.17 | 13.74 |
June | 23.27 | 22.16 |
July | 23.29 | 22.71 |
August | 23.27 | 21.74 |
September | 22.86 | 18.54 |
October | 20.52 | 7.12 |
November | 19.54 | 3.03 |
December | 19.19 | -1.0 |
Annual Sum or Average | 21.07 | 10.02 |
Minimum of Months | 19.19 | -1.0 |
Maximum of Months | 23.29 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM202_205
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.04 | 0.85 |
February | 20.96 | -0.2 |
March | 21.22 | 4.82 |
April | 21.30 | 6.08 |
May | 21.71 | 13.74 |
June | 21.76 | 22.16 |
July | 21.76 | 22.71 |
August | 21.75 | 21.74 |
September | 21.74 | 18.54 |
October | 21.38 | 7.12 |
November | 21.15 | 3.03 |
December | 20.99 | -1.0 |
Annual Sum or Average | 21.40 | 10.02 |
Minimum of Months | 20.96 | -1.0 |
Maximum of Months | 21.76 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM206_208
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.09 | 0.85 |
February | 21.00 | -0.2 |
March | 21.25 | 4.82 |
April | 21.33 | 6.08 |
May | 21.72 | 13.74 |
June | 21.76 | 22.16 |
July | 21.76 | 22.71 |
August | 21.75 | 21.74 |
September | 21.74 | 18.54 |
October | 21.41 | 7.12 |
November | 21.19 | 3.03 |
December | 21.02 | -1.0 |
Annual Sum or Average | 21.42 | 10.02 |
Minimum of Months | 21.00 | -1.0 |
Maximum of Months | 21.76 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM209_212
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.13 | 0.85 |
February | 21.03 | -0.2 |
March | 21.28 | 4.82 |
April | 21.35 | 6.08 |
May | 21.72 | 13.74 |
June | 21.75 | 22.16 |
July | 21.75 | 22.71 |
August | 21.75 | 21.74 |
September | 21.74 | 18.54 |
October | 21.44 | 7.12 |
November | 21.23 | 3.03 |
December | 21.06 | -1.0 |
Annual Sum or Average | 21.44 | 10.02 |
Minimum of Months | 21.03 | -1.0 |
Maximum of Months | 21.75 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM213
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.88 | 0.85 |
February | 20.78 | -0.2 |
March | 21.03 | 4.82 |
April | 21.11 | 6.08 |
May | 21.65 | 13.74 |
June | 21.75 | 22.16 |
July | 21.75 | 22.71 |
August | 21.75 | 21.74 |
September | 21.72 | 18.54 |
October | 21.25 | 7.12 |
November | 21.00 | 3.03 |
December | 20.81 | -1.0 |
Annual Sum or Average | 21.29 | 10.02 |
Minimum of Months | 20.78 | -1.0 |
Maximum of Months | 21.75 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM214
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.48 | 0.85 |
February | 21.35 | -0.2 |
March | 21.39 | 4.82 |
April | 21.39 | 6.08 |
May | 21.72 | 13.74 |
June | 21.76 | 22.16 |
July | 21.76 | 22.71 |
August | 21.75 | 21.74 |
September | 21.75 | 18.54 |
October | 21.52 | 7.12 |
November | 21.50 | 3.03 |
December | 21.29 | -1.0 |
Annual Sum or Average | 21.55 | 10.02 |
Minimum of Months | 21.29 | -1.0 |
Maximum of Months | 21.76 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM215_218
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.13 | 0.85 |
February | 23.02 | -0.2 |
March | 23.15 | 4.82 |
April | 23.19 | 6.08 |
May | 23.33 | 13.74 |
June | 23.33 | 22.16 |
July | 23.33 | 22.71 |
August | 23.33 | 21.74 |
September | 23.33 | 18.54 |
October | 23.23 | 7.12 |
November | 23.17 | 3.03 |
December | 22.83 | -1.0 |
Annual Sum or Average | 23.20 | 10.02 |
Minimum of Months | 22.83 | -1.0 |
Maximum of Months | 23.33 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: ELEVATORCOREFLR2
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 31.56 | 0.85 |
February | 31.09 | -0.2 |
March | 31.44 | 4.82 |
April | 31.46 | 6.08 |
May | 32.59 | 13.74 |
June | 33.44 | 22.16 |
July | 33.50 | 22.71 |
August | 33.49 | 21.74 |
September | 33.21 | 18.54 |
October | 32.08 | 7.12 |
November | 31.65 | 3.03 |
December | 30.83 | -1.0 |
Annual Sum or Average | 32.20 | 10.02 |
Minimum of Months | 30.83 | -1.0 |
Maximum of Months | 33.50 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM219
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.01 | 0.85 |
February | 21.95 | -0.2 |
March | 22.05 | 4.82 |
April | 22.07 | 6.08 |
May | 22.42 | 13.74 |
June | 22.97 | 22.16 |
July | 23.02 | 22.71 |
August | 23.02 | 21.74 |
September | 22.75 | 18.54 |
October | 22.24 | 7.12 |
November | 22.06 | 3.03 |
December | 21.90 | -1.0 |
Annual Sum or Average | 22.37 | 10.02 |
Minimum of Months | 21.90 | -1.0 |
Maximum of Months | 23.02 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM220_223
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.56 | 0.85 |
February | 21.47 | -0.2 |
March | 21.49 | 4.82 |
April | 21.49 | 6.08 |
May | 21.74 | 13.74 |
June | 21.75 | 22.16 |
July | 21.76 | 22.71 |
August | 21.75 | 21.74 |
September | 21.75 | 18.54 |
October | 21.56 | 7.12 |
November | 21.58 | 3.03 |
December | 21.42 | -1.0 |
Annual Sum or Average | 21.61 | 10.02 |
Minimum of Months | 21.42 | -1.0 |
Maximum of Months | 21.76 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM224
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.47 | 0.85 |
February | 21.34 | -0.2 |
March | 21.38 | 4.82 |
April | 21.39 | 6.08 |
May | 21.72 | 13.74 |
June | 21.76 | 22.16 |
July | 21.76 | 22.71 |
August | 21.76 | 21.74 |
September | 21.75 | 18.54 |
October | 21.52 | 7.12 |
November | 21.50 | 3.03 |
December | 21.29 | -1.0 |
Annual Sum or Average | 21.55 | 10.02 |
Minimum of Months | 21.29 | -1.0 |
Maximum of Months | 21.76 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: FRONTSTORAGEFLR2
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.54 | 0.85 |
February | 19.59 | -0.2 |
March | 20.36 | 4.82 |
April | 20.46 | 6.08 |
May | 22.63 | 13.74 |
June | 24.65 | 22.16 |
July | 24.81 | 22.71 |
August | 24.68 | 21.74 |
September | 24.02 | 18.54 |
October | 21.58 | 7.12 |
November | 20.68 | 3.03 |
December | 18.97 | -1.0 |
Annual Sum or Average | 21.93 | 10.02 |
Minimum of Months | 18.97 | -1.0 |
Maximum of Months | 24.81 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: FRONTSTAIRSFLR2
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 18.44 | 0.85 |
February | 16.82 | -0.2 |
March | 18.14 | 4.82 |
April | 18.35 | 6.08 |
May | 21.92 | 13.74 |
June | 25.39 | 22.16 |
July | 25.61 | 22.71 |
August | 25.36 | 21.74 |
September | 24.07 | 18.54 |
October | 19.96 | 7.12 |
November | 18.60 | 3.03 |
December | 15.71 | -1.0 |
Annual Sum or Average | 20.72 | 10.02 |
Minimum of Months | 15.71 | -1.0 |
Maximum of Months | 25.61 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: REARSTAIRSFLR3
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 18.68 | 0.85 |
February | 17.24 | -0.2 |
March | 18.30 | 4.82 |
April | 18.46 | 6.08 |
May | 21.77 | 13.74 |
June | 24.90 | 22.16 |
July | 24.98 | 22.71 |
August | 24.75 | 21.74 |
September | 23.63 | 18.54 |
October | 19.89 | 7.12 |
November | 18.81 | 3.03 |
December | 16.20 | -1.0 |
Annual Sum or Average | 20.65 | 10.02 |
Minimum of Months | 16.20 | -1.0 |
Maximum of Months | 24.98 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: CORRIDORFLR3
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.46 | 0.85 |
February | 21.40 | -0.2 |
March | 21.88 | 4.82 |
April | 21.94 | 6.08 |
May | 23.28 | 13.74 |
June | 23.88 | 22.16 |
July | 23.88 | 22.71 |
August | 23.88 | 21.74 |
September | 23.69 | 18.54 |
October | 22.34 | 7.12 |
November | 21.69 | 3.03 |
December | 21.36 | -1.0 |
Annual Sum or Average | 22.57 | 10.02 |
Minimum of Months | 21.36 | -1.0 |
Maximum of Months | 23.88 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: REARSTORAGEFLR3
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 16.40 | 0.85 |
February | 15.20 | -0.2 |
March | 16.61 | 4.82 |
April | 17.02 | 6.08 |
May | 20.76 | 13.74 |
June | 24.31 | 22.16 |
July | 24.38 | 22.71 |
August | 24.00 | 21.74 |
September | 22.62 | 18.54 |
October | 18.18 | 7.12 |
November | 16.68 | 3.03 |
December | 14.25 | -1.0 |
Annual Sum or Average | 19.22 | 10.02 |
Minimum of Months | 14.25 | -1.0 |
Maximum of Months | 24.38 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM301
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.04 | 0.85 |
February | 19.03 | -0.2 |
March | 19.65 | 4.82 |
April | 19.74 | 6.08 |
May | 21.80 | 13.74 |
June | 23.22 | 22.16 |
July | 23.25 | 22.71 |
August | 23.21 | 21.74 |
September | 22.67 | 18.54 |
October | 20.03 | 7.12 |
November | 19.25 | 3.03 |
December | 19.02 | -1.0 |
Annual Sum or Average | 20.84 | 10.02 |
Minimum of Months | 19.02 | -1.0 |
Maximum of Months | 23.25 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM302_305
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.09 | 0.85 |
February | 19.06 | -0.2 |
March | 19.72 | 4.82 |
April | 19.87 | 6.08 |
May | 21.95 | 13.74 |
June | 23.26 | 22.16 |
July | 23.29 | 22.71 |
August | 23.25 | 21.74 |
September | 22.75 | 18.54 |
October | 20.17 | 7.12 |
November | 19.31 | 3.03 |
December | 19.07 | -1.0 |
Annual Sum or Average | 20.91 | 10.02 |
Minimum of Months | 19.06 | -1.0 |
Maximum of Months | 23.29 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM306_308
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.13 | 0.85 |
February | 19.10 | -0.2 |
March | 19.77 | 4.82 |
April | 19.96 | 6.08 |
May | 22.00 | 13.74 |
June | 23.25 | 22.16 |
July | 23.28 | 22.71 |
August | 23.24 | 21.74 |
September | 22.75 | 18.54 |
October | 20.25 | 7.12 |
November | 19.36 | 3.03 |
December | 19.10 | -1.0 |
Annual Sum or Average | 20.94 | 10.02 |
Minimum of Months | 19.10 | -1.0 |
Maximum of Months | 23.28 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM309_312
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.03 | 0.85 |
February | 20.94 | -0.2 |
March | 21.20 | 4.82 |
April | 21.28 | 6.08 |
May | 21.70 | 13.74 |
June | 21.75 | 22.16 |
July | 21.75 | 22.71 |
August | 21.75 | 21.74 |
September | 21.74 | 18.54 |
October | 21.36 | 7.12 |
November | 21.14 | 3.03 |
December | 20.98 | -1.0 |
Annual Sum or Average | 21.39 | 10.02 |
Minimum of Months | 20.94 | -1.0 |
Maximum of Months | 21.75 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM313
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.09 | 0.85 |
February | 19.05 | -0.2 |
March | 19.67 | 4.82 |
April | 19.77 | 6.08 |
May | 21.82 | 13.74 |
June | 23.25 | 22.16 |
July | 23.28 | 22.71 |
August | 23.24 | 21.74 |
September | 22.72 | 18.54 |
October | 20.17 | 7.12 |
November | 19.31 | 3.03 |
December | 19.04 | -1.0 |
Annual Sum or Average | 20.88 | 10.02 |
Minimum of Months | 19.04 | -1.0 |
Maximum of Months | 23.28 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM314
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.33 | 0.85 |
February | 21.19 | -0.2 |
March | 21.25 | 4.82 |
April | 21.24 | 6.08 |
May | 21.68 | 13.74 |
June | 21.75 | 22.16 |
July | 21.76 | 22.71 |
August | 21.75 | 21.74 |
September | 21.74 | 18.54 |
October | 21.43 | 7.12 |
November | 21.37 | 3.03 |
December | 21.15 | -1.0 |
Annual Sum or Average | 21.47 | 10.02 |
Minimum of Months | 21.15 | -1.0 |
Maximum of Months | 21.76 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM315_318
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.59 | 0.85 |
February | 21.49 | -0.2 |
March | 21.51 | 4.82 |
April | 21.51 | 6.08 |
May | 21.74 | 13.74 |
June | 21.76 | 22.16 |
July | 21.76 | 22.71 |
August | 21.75 | 21.74 |
September | 21.75 | 18.54 |
October | 21.57 | 7.12 |
November | 21.59 | 3.03 |
December | 21.44 | -1.0 |
Annual Sum or Average | 21.62 | 10.02 |
Minimum of Months | 21.44 | -1.0 |
Maximum of Months | 21.76 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: ELEVATORCOREFLR3
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.49 | 0.85 |
February | 22.97 | -0.2 |
March | 23.45 | 4.82 |
April | 23.52 | 6.08 |
May | 25.08 | 13.74 |
June | 26.14 | 22.16 |
July | 26.19 | 22.71 |
August | 26.16 | 21.74 |
September | 25.80 | 18.54 |
October | 24.19 | 7.12 |
November | 23.61 | 3.03 |
December | 22.62 | -1.0 |
Annual Sum or Average | 24.44 | 10.02 |
Minimum of Months | 22.62 | -1.0 |
Maximum of Months | 26.19 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM319
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.90 | 0.85 |
February | 21.49 | -0.2 |
March | 21.93 | 4.82 |
April | 22.07 | 6.08 |
May | 23.16 | 13.74 |
June | 23.33 | 22.16 |
July | 23.33 | 22.71 |
August | 23.33 | 21.74 |
September | 23.28 | 18.54 |
October | 22.41 | 7.12 |
November | 22.05 | 3.03 |
December | 21.34 | -1.0 |
Annual Sum or Average | 22.47 | 10.02 |
Minimum of Months | 21.34 | -1.0 |
Maximum of Months | 23.33 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM320_323
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.50 | 0.85 |
February | 21.39 | -0.2 |
March | 21.41 | 4.82 |
April | 21.40 | 6.08 |
May | 21.72 | 13.74 |
June | 21.75 | 22.16 |
July | 21.75 | 22.71 |
August | 21.75 | 21.74 |
September | 21.75 | 18.54 |
October | 21.51 | 7.12 |
November | 21.51 | 3.03 |
December | 21.34 | -1.0 |
Annual Sum or Average | 21.57 | 10.02 |
Minimum of Months | 21.34 | -1.0 |
Maximum of Months | 21.75 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM324
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.33 | 0.85 |
February | 20.04 | -0.2 |
March | 20.52 | 4.82 |
April | 20.59 | 6.08 |
May | 22.33 | 13.74 |
June | 23.27 | 22.16 |
July | 23.30 | 22.71 |
August | 23.29 | 21.74 |
September | 23.03 | 18.54 |
October | 21.37 | 7.12 |
November | 20.63 | 3.03 |
December | 19.91 | -1.0 |
Annual Sum or Average | 21.56 | 10.02 |
Minimum of Months | 19.91 | -1.0 |
Maximum of Months | 23.30 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: FRONTSTORAGEFLR3
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.59 | 0.85 |
February | 18.56 | -0.2 |
March | 19.53 | 4.82 |
April | 19.69 | 6.08 |
May | 22.41 | 13.74 |
June | 24.91 | 22.16 |
July | 25.07 | 22.71 |
August | 24.92 | 21.74 |
September | 24.05 | 18.54 |
October | 20.94 | 7.12 |
November | 19.80 | 3.03 |
December | 17.84 | -1.0 |
Annual Sum or Average | 21.46 | 10.02 |
Minimum of Months | 17.84 | -1.0 |
Maximum of Months | 25.07 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: FRONTSTAIRSFLR3
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 17.56 | 0.85 |
February | 15.83 | -0.2 |
March | 17.38 | 4.82 |
April | 17.66 | 6.08 |
May | 21.75 | 13.74 |
June | 25.69 | 22.16 |
July | 25.91 | 22.71 |
August | 25.62 | 21.74 |
September | 24.11 | 18.54 |
October | 19.36 | 7.12 |
November | 17.77 | 3.03 |
December | 14.62 | -1.0 |
Annual Sum or Average | 20.30 | 10.02 |
Minimum of Months | 14.62 | -1.0 |
Maximum of Months | 25.91 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: REARSTAIRSFLR4
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 17.32 | 0.85 |
February | 15.97 | -0.2 |
March | 17.37 | 4.82 |
April | 17.57 | 6.08 |
May | 21.53 | 13.74 |
June | 25.26 | 22.16 |
July | 25.29 | 22.71 |
August | 25.05 | 21.74 |
September | 23.58 | 18.54 |
October | 18.96 | 7.12 |
November | 17.65 | 3.03 |
December | 14.82 | -1.0 |
Annual Sum or Average | 20.05 | 10.02 |
Minimum of Months | 14.82 | -1.0 |
Maximum of Months | 25.29 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: CORRIDORFLR4
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.36 | 0.85 |
February | 21.37 | -0.2 |
March | 21.69 | 4.82 |
April | 21.75 | 6.08 |
May | 22.77 | 13.74 |
June | 23.77 | 22.16 |
July | 23.81 | 22.71 |
August | 23.75 | 21.74 |
September | 23.30 | 18.54 |
October | 21.94 | 7.12 |
November | 21.51 | 3.03 |
December | 21.31 | -1.0 |
Annual Sum or Average | 22.37 | 10.02 |
Minimum of Months | 21.31 | -1.0 |
Maximum of Months | 23.81 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: REARSTORAGEFLR4
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 15.41 | 0.85 |
February | 14.29 | -0.2 |
March | 15.97 | 4.82 |
April | 16.40 | 6.08 |
May | 20.59 | 13.74 |
June | 24.61 | 22.16 |
July | 24.63 | 22.71 |
August | 24.24 | 21.74 |
September | 22.56 | 18.54 |
October | 17.45 | 7.12 |
November | 15.83 | 3.03 |
December | 13.24 | -1.0 |
Annual Sum or Average | 18.79 | 10.02 |
Minimum of Months | 13.24 | -1.0 |
Maximum of Months | 24.63 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM401
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.77 | 0.85 |
February | 20.78 | -0.2 |
March | 21.03 | 4.82 |
April | 21.09 | 6.08 |
May | 21.66 | 13.74 |
June | 21.76 | 22.16 |
July | 21.76 | 22.71 |
August | 21.75 | 21.74 |
September | 21.72 | 18.54 |
October | 21.20 | 7.12 |
November | 20.94 | 3.03 |
December | 20.74 | -1.0 |
Annual Sum or Average | 21.27 | 10.02 |
Minimum of Months | 20.74 | -1.0 |
Maximum of Months | 21.76 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM402_405
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.07 | 0.85 |
February | 19.07 | -0.2 |
March | 19.62 | 4.82 |
April | 19.78 | 6.08 |
May | 21.51 | 13.74 |
June | 23.04 | 22.16 |
July | 23.12 | 22.71 |
August | 23.02 | 21.74 |
September | 22.35 | 18.54 |
October | 19.93 | 7.12 |
November | 19.25 | 3.03 |
December | 19.06 | -1.0 |
Annual Sum or Average | 20.74 | 10.02 |
Minimum of Months | 19.06 | -1.0 |
Maximum of Months | 23.12 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM406_408
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.09 | 0.85 |
February | 19.09 | -0.2 |
March | 19.64 | 4.82 |
April | 19.81 | 6.08 |
May | 21.53 | 13.74 |
June | 23.02 | 22.16 |
July | 23.11 | 22.71 |
August | 23.00 | 21.74 |
September | 22.33 | 18.54 |
October | 19.96 | 7.12 |
November | 19.27 | 3.03 |
December | 19.07 | -1.0 |
Annual Sum or Average | 20.75 | 10.02 |
Minimum of Months | 19.07 | -1.0 |
Maximum of Months | 23.11 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM409_412
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.01 | 0.85 |
February | 20.97 | -0.2 |
March | 21.21 | 4.82 |
April | 21.27 | 6.08 |
May | 21.72 | 13.74 |
June | 21.76 | 22.16 |
July | 21.76 | 22.71 |
August | 21.75 | 21.74 |
September | 21.74 | 18.54 |
October | 21.36 | 7.12 |
November | 21.16 | 3.03 |
December | 20.95 | -1.0 |
Annual Sum or Average | 21.39 | 10.02 |
Minimum of Months | 20.95 | -1.0 |
Maximum of Months | 21.76 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM413
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.07 | 0.85 |
February | 19.05 | -0.2 |
March | 19.61 | 4.82 |
April | 19.72 | 6.08 |
May | 21.50 | 13.74 |
June | 23.05 | 22.16 |
July | 23.13 | 22.71 |
August | 23.03 | 21.74 |
September | 22.38 | 18.54 |
October | 19.96 | 7.12 |
November | 19.26 | 3.03 |
December | 19.04 | -1.0 |
Annual Sum or Average | 20.74 | 10.02 |
Minimum of Months | 19.04 | -1.0 |
Maximum of Months | 23.13 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM414
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.81 | 0.85 |
February | 19.71 | -0.2 |
March | 20.16 | 4.82 |
April | 20.16 | 6.08 |
May | 21.80 | 13.74 |
June | 23.08 | 22.16 |
July | 23.15 | 22.71 |
August | 23.09 | 21.74 |
September | 22.61 | 18.54 |
October | 20.65 | 7.12 |
November | 20.06 | 3.03 |
December | 19.55 | -1.0 |
Annual Sum or Average | 21.16 | 10.02 |
Minimum of Months | 19.55 | -1.0 |
Maximum of Months | 23.15 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM415_418
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.52 | 0.85 |
February | 21.42 | -0.2 |
March | 21.43 | 4.82 |
April | 21.39 | 6.08 |
May | 21.74 | 13.74 |
June | 21.76 | 22.16 |
July | 21.76 | 22.71 |
August | 21.75 | 21.74 |
September | 21.75 | 18.54 |
October | 21.47 | 7.12 |
November | 21.52 | 3.03 |
December | 21.35 | -1.0 |
Annual Sum or Average | 21.57 | 10.02 |
Minimum of Months | 21.35 | -1.0 |
Maximum of Months | 21.76 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: ELEVATORCOREFLR4
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.01 | 0.85 |
February | 20.61 | -0.2 |
March | 21.26 | 4.82 |
April | 21.37 | 6.08 |
May | 23.21 | 13.74 |
June | 24.72 | 22.16 |
July | 24.75 | 22.71 |
August | 24.67 | 21.74 |
September | 24.03 | 18.54 |
October | 21.90 | 7.12 |
November | 21.25 | 3.03 |
December | 20.16 | -1.0 |
Annual Sum or Average | 22.42 | 10.02 |
Minimum of Months | 20.16 | -1.0 |
Maximum of Months | 24.75 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM419
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.49 | 0.85 |
February | 21.38 | -0.2 |
March | 21.40 | 4.82 |
April | 21.38 | 6.08 |
May | 21.73 | 13.74 |
June | 21.76 | 22.16 |
July | 21.76 | 22.71 |
August | 21.76 | 21.74 |
September | 21.75 | 18.54 |
October | 21.47 | 7.12 |
November | 21.49 | 3.03 |
December | 21.31 | -1.0 |
Annual Sum or Average | 21.56 | 10.02 |
Minimum of Months | 21.31 | -1.0 |
Maximum of Months | 21.76 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM420_423
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.50 | 0.85 |
February | 21.40 | -0.2 |
March | 21.41 | 4.82 |
April | 21.37 | 6.08 |
May | 21.73 | 13.74 |
June | 21.76 | 22.16 |
July | 21.76 | 22.71 |
August | 21.75 | 21.74 |
September | 21.75 | 18.54 |
October | 21.46 | 7.12 |
November | 21.50 | 3.03 |
December | 21.33 | -1.0 |
Annual Sum or Average | 21.56 | 10.02 |
Minimum of Months | 21.33 | -1.0 |
Maximum of Months | 21.76 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM424
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.34 | 0.85 |
February | 21.23 | -0.2 |
March | 21.26 | 4.82 |
April | 21.24 | 6.08 |
May | 21.71 | 13.74 |
June | 21.76 | 22.16 |
July | 21.76 | 22.71 |
August | 21.75 | 21.74 |
September | 21.74 | 18.54 |
October | 21.41 | 7.12 |
November | 21.38 | 3.03 |
December | 21.14 | -1.0 |
Annual Sum or Average | 21.48 | 10.02 |
Minimum of Months | 21.14 | -1.0 |
Maximum of Months | 21.76 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: FRONTSTORAGEFLR4
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 18.82 | 0.85 |
February | 17.92 | -0.2 |
March | 19.10 | 4.82 |
April | 19.29 | 6.08 |
May | 22.30 | 13.74 |
June | 25.06 | 22.16 |
July | 25.16 | 22.71 |
August | 24.98 | 21.74 |
September | 23.88 | 18.54 |
October | 20.33 | 7.12 |
November | 19.15 | 3.03 |
December | 17.11 | -1.0 |
Annual Sum or Average | 21.11 | 10.02 |
Minimum of Months | 17.11 | -1.0 |
Maximum of Months | 25.16 | 22.71 |
Report: MONTHLY INDOOR TEMP
For: FRONTSTAIRSFLR4
Timestamp: 2018-10-19 10:15:39
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 16.55 | 0.85 |
February | 14.92 | -0.2 |
March | 16.76 | 4.82 |
April | 17.07 | 6.08 |
May | 21.61 | 13.74 |
June | 25.95 | 22.16 |
July | 26.10 | 22.71 |
August | 25.80 | 21.74 |
September | 23.99 | 18.54 |
October | 18.61 | 7.12 |
November | 16.93 | 3.03 |
December | 13.75 | -1.0 |
Annual Sum or Average | 19.86 | 10.02 |
Minimum of Months | 13.75 | -1.0 |
Maximum of Months | 26.10 | 22.71 |
Report: PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2018-10-19 10:15:39
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [Invalid/Undefined] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined] | |
January | 0.150817E+12 | 131430.836 | 05-JAN-07:15 | 15177.258 | 39465.561 | 9069.195 | 63354.811 | 167.898 | 4188.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
February | 0.140700E+12 | 132659.346 | 12-FEB-07:15 | 15177.258 | 39465.561 | 9082.971 | 68761.198 | 164.245 | 0.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
March | 0.143796E+12 | 130132.625 | 19-MAR-06:00 | 15177.258 | 39465.561 | 9083.015 | 66249.116 | 149.561 | 0.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
April | 0.133942E+12 | 104162.754 | 17-APR-06:15 | 15102.841 | 39465.561 | 9053.797 | 40314.415 | 218.027 | 0.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
May | 0.137013E+12 | 82849.259 | 13-MAY-07:00 | 17492.219 | 43276.576 | 9530.514 | 0.000 | 12541.838 | 0.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
June | 0.150301E+12 | 91712.396 | 30-JUN-07:00 | 17492.219 | 43276.576 | 9530.514 | 0.000 | 21404.975 | 0.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
July | 0.157110E+12 | 92225.467 | 15-JUL-07:00 | 17566.637 | 43276.576 | 9530.514 | 0.000 | 21843.629 | 0.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.155200E+12 | 92144.362 | 05-AUG-07:00 | 17715.471 | 43276.576 | 9530.514 | 0.000 | 21613.688 | 0.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.142553E+12 | 87952.884 | 09-SEP-07:00 | 17641.054 | 43276.576 | 9530.514 | 0.000 | 17496.628 | 0.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
October | 0.141985E+12 | 112048.705 | 30-OCT-06:15 | 15177.258 | 39465.561 | 9053.797 | 43938.372 | 217.604 | 4188.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
November | 0.141813E+12 | 116399.285 | 30-NOV-07:15 | 15177.258 | 39465.561 | 9065.857 | 52495.065 | 187.430 | 0.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
December | 0.165986E+12 | 146902.011 | 23-DEC-07:15 | 13316.689 | 34010.661 | 9108.396 | 86186.534 | 83.619 | 4188.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.176122E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||
Minimum of Months | 0.133942E+12 | 82849.259 | 13316.689 | 34010.661 | 9053.797 | 0.000 | 83.619 | 0.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.165986E+12 | 146902.011 | 17715.471 | 43276.576 | 9530.514 | 86186.534 | 21843.629 | 4188.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: PEAK GAS DEMAND
For: Meter
Timestamp: 2018-10-19 10:15:39
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC {AT MAX/MIN} [W] | INTERIOREQUIPMENT:GAS {AT MAX/MIN} [W] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT {AT MAX/MIN} [W] | WATERSYSTEMS:GAS {AT MAX/MIN} [W] | WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.106678E+12 | 109140.093 | 05-JAN-10:00 | 14691.046 | 40096.028 | 0.000 | 54353.019 | 54353.019 | 54353.019 | 14691.046 |
February | 0.986907E+11 | 108693.949 | 11-FEB-11:15 | 9705.500 | 40096.028 | 0.000 | 58892.421 | 58892.421 | 58892.421 | 9705.500 |
March | 0.102951E+12 | 109007.570 | 04-MAR-10:00 | 10449.020 | 40096.028 | 0.000 | 58462.522 | 58462.522 | 58462.522 | 10449.020 |
April | 0.957064E+11 | 101138.427 | 16-APR-09:15 | 4180.419 | 40096.028 | 0.000 | 56861.980 | 56861.980 | 56861.980 | 4180.419 |
May | 0.908922E+11 | 97300.740 | 05-MAY-08:15 | 0.000 | 40096.028 | 0.000 | 57204.712 | 57204.712 | 57204.712 | 0.000 |
June | 0.841458E+11 | 93088.563 | 02-JUN-09:00 | 0.000 | 40096.028 | 0.000 | 52992.535 | 52992.535 | 52992.535 | 0.000 |
July | 0.847039E+11 | 91748.862 | 04-JUL-08:15 | 0.000 | 40096.028 | 0.000 | 51652.834 | 51652.834 | 51652.834 | 0.000 |
August | 0.839488E+11 | 90825.463 | 04-AUG-08:15 | 0.000 | 40096.028 | 0.000 | 50729.435 | 50729.435 | 50729.435 | 0.000 |
September | 0.823342E+11 | 91912.279 | 22-SEP-08:15 | 0.000 | 40096.028 | 0.000 | 51816.251 | 51816.251 | 51816.251 | 0.000 |
October | 0.921180E+11 | 98747.186 | 31-OCT-08:15 | 4620.494 | 40096.028 | 0.000 | 54030.664 | 54030.664 | 54030.664 | 4620.494 |
November | 0.955712E+11 | 100956.853 | 29-NOV-09:45 | 4899.801 | 40096.028 | 0.000 | 55961.024 | 55961.024 | 55961.024 | 4899.801 |
December | 0.108612E+12 | 111901.013 | 22-DEC-11:45 | 14713.516 | 40096.028 | 0.000 | 57091.469 | 57091.469 | 57091.469 | 14713.516 |
Annual Sum or Average | 0.112635E+13 | 0.000 | ||||||||
Minimum of Months | 0.823342E+11 | 90825.463 | 0.000 | 40096.028 | 0.000 | 50729.435 | 50729.435 | 50729.435 | 0.000 | |
Maximum of Months | 0.108612E+12 | 111901.013 | 14713.516 | 40096.028 | 0.000 | 58892.421 | 58892.421 | 58892.421 | 14713.516 |