Table of Contents

Program Version:EnergyPlus, Version 8.6.0-Unknown, YMD=2019.02.14 08:45

Tabular Output Report in Format: HTML

Building: SF+CZ1ASC+USA_HI_Honolulu.Intl.AP.911820+gasfurnace+slab+IECC_2015

Environment: ANNUAL ** Honolulu Intl Arpt HI USA TMY3 WMO#=911820

Simulation Timestamp: 2019-02-14 08:45:47


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2019-02-14 08:45:47

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [kBtu] Energy Per Total Building Area [kBtu/ft2] Energy Per Conditioned Building Area [kBtu/ft2]
Total Site Energy 58200.90 16.32 24.48
Net Site Energy 58200.90 16.32 24.48
Total Source Energy 160565.06 45.03 67.55
Net Source Energy 160565.06 45.03 67.55


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [ft2]
Total Building Area 3565.64
Net Conditioned Building Area 2377.10
Unconditioned Building Area 1188.55


End Uses

Electricity [kBtu] Natural Gas [kBtu] Additional Fuel [kBtu] District Cooling [kBtu] District Heating [kBtu] Water [gal]
Heating 0.00 51.83 0.00 0.00 0.00 0.00
Cooling 15217.61 0.00 0.00 0.00 0.00 0.00
Interior Lighting 4046.24 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 870.96 0.00 0.00 0.00 0.00 0.00
Interior Equipment 23953.98 11013.86 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 2627.93 0.00 0.00 0.00 0.00 0.00
Pumps 78.91 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 339.58 0.00 0.00 0.00 26459.31
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 46795.62 11405.27 0.00 0.00 0.00 26459.31
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [kBtu] Natural Gas [kBtu] Additional Fuel [kBtu] District Cooling [kBtu] District Heating [kBtu] Water [gal]
Heating General 0.00 51.83 0.00 0.00 0.00 0.00
Cooling General 15217.61 0.00 0.00 0.00 0.00 0.00
Interior Lighting General 4046.24 0.00 0.00 0.00 0.00 0.00
Exterior Lighting Exterior-Lights 780.36 0.00 0.00 0.00 0.00 0.00
  Garage-Lights 90.60 0.00 0.00 0.00 0.00 0.00
Interior Equipment dishwasher 630.62 0.00 0.00 0.00 0.00 0.00
  refrigerator 2283.13 0.00 0.00 0.00 0.00 0.00
  clotheswasher 322.06 0.00 0.00 0.00 0.00 0.00
  gas_dryer 259.30 5282.57 0.00 0.00 0.00 0.00
  gas_range 0.00 4496.23 0.00 0.00 0.00 0.00
  television 0.00 0.00 0.00 0.00 0.00 0.00
  gas_mels 10247.12 1235.06 0.00 0.00 0.00 0.00
  IECC_adj 10211.75 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 2627.93 0.00 0.00 0.00 0.00 0.00
Pumps General 78.91 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 339.58 0.00 0.00 0.00 0.00
  Domestic Hot Water 0.00 0.00 0.00 0.00 0.00 26459.31
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [kBtu/ft2] Natural Gas Intensity [kBtu/ft2] Additional Fuel Intensity [kBtu/ft2] District Cooling Intensity [kBtu/ft2] District Heating Intensity [kBtu/ft2] Water Intensity [gal/ft2]
Lighting 2.07 0.00 0.00 0.00 0.00 0.00
HVAC 7.54 0.16 0.00 0.00 0.00 11.13
Other 10.08 4.63 0.00 0.00 0.00 0.00
Total 19.69 4.80 0.00 0.00 0.00 11.13


Utility Use Per Total Floor Area

Electricity Intensity [kBtu/ft2] Natural Gas Intensity [kBtu/ft2] Additional Fuel Intensity [kBtu/ft2] District Cooling Intensity [kBtu/ft2] District Heating Intensity [kBtu/ft2] Water Intensity [gal/ft2]
Lighting 1.38 0.00 0.00 0.00 0.00 0.00
HVAC 5.03 0.11 0.00 0.00 0.00 7.42
Other 6.72 3.09 0.00 0.00 0.00 0.00
Total 13.12 3.20 0.00 0.00 0.00 7.42


Electric Loads Satisfied

Electricity [kBtu] Percent Electricity [%]
Fuel-Fired Power Generation 0.000 0.00
High Temperature Geothermal* 0.000 0.00
Photovoltaic Power 0.000 0.00
Wind Power 0.000 0.00
Power Conversion 0.000 0.00
Net Decrease in On-Site Storage 0.000 0.00
Total On-Site Electric Sources 0.000 0.00
     
Electricity Coming From Utility 46795.624 100.00
Surplus Electricity Going To Utility 0.000 0.00
Net Electricity From Utility 46795.624 100.00
     
Total On-Site and Utility Electric Sources 46795.624 100.00
Total Electricity End Uses 46795.624 100.00


On-Site Thermal Sources

Heat [kBtu] Percent Heat [%]
Water-Side Heat Recovery 0.00 0.00
Air to Air Heat Recovery for Cooling 0.00 0.00
Air to Air Heat Recovery for Heating 0.00 0.00
High-Temperature Geothermal* 0.00 0.00
Solar Water Thermal 13773.14 100.00
Solar Air Thermal 0.00 0.00
Total On-Site Thermal Sources 13773.14 100.00


Water Source Summary

Water [gal] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 26459.31 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 26459.31 100.00
Total Water End Uses 26459.31 100.00


Setpoint Not Met Criteria

Degrees [deltaF]
Tolerance for Zone Heating Setpoint Not Met Time 0.36
Tolerance for Zone Cooling Setpoint Not Met Time 0.36


Comfort and Setpoint Not Met Summary

Facility [Hours]
Time Setpoint Not Met During Occupied Heating 0.00
Time Setpoint Not Met During Occupied Cooling 0.00
Time Not Comfortable Based on Simple ASHRAE 55-2004 2634.50


Note 1: An asterisk (*) indicates that the feature is not yet implemented.

Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Adaptive Comfort Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

FANSPLIT

| CENTRAL SYSTEM_UNIT1 |

COILLOADS

| MAIN FUEL HEATING COIL_UNIT1 | DX COOLING COIL_UNIT1 |

WATER HEATER: LOADS

| INSTANTANEOUS WATER HEATER | STORAGE TANK |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2019-02-14 08:45:47

General

Value
Program Version and Build EnergyPlus, Version 8.6.0-Unknown, YMD=2019.02.14 08:45
RunPeriod ANNUAL
Weather File Honolulu Intl Arpt HI USA TMY3 WMO#=911820
Latitude [deg] 21.32
Longitude [deg] -157.9
Elevation [ft] 6.56
Time Zone -10.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [ft2] 2517.81 676.95 581.95 676.95 581.95
Above Ground Wall Area [ft2] 2517.81 676.95 581.95 676.95 581.95
Window Opening Area [ft2] 355.40 88.85 88.85 88.85 88.85
Gross Window-Wall Ratio [%] 14.12 13.12 15.27 13.12 15.27
Above Ground Window-Wall Ratio [%] 14.12 13.12 15.27 13.12 15.27


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [ft2] 1184.67 338.48 253.86 338.48 253.86
Above Ground Wall Area [ft2] 1184.67 338.48 253.86 338.48 253.86
Window Opening Area [ft2] 177.70 44.43 44.43 44.43 44.43
Gross Window-Wall Ratio [%] 15.00 13.12 17.50 13.12 17.50
Above Ground Window-Wall Ratio [%] 15.00 13.12 17.50 13.12 17.50


Skylight-Roof Ratio

Total
Gross Roof Area [ft2] 1252.76
Skylight Area [ft2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [ft2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [ft3] Multipliers Above Ground Gross Wall Area [ft2] Underground Gross Wall Area [ft2] Window Glass Area [ft2] Opening Area [ft2] Lighting [Btu/h-ft2] People [ft2 per person] Plug and Process [Btu/h-ft2]
LIVING_UNIT1 2377.10 Yes Yes 10104.44 1.00 1184.67 0.00 177.70 177.70 0.5541 792.37 3.1791
UNCOND_LIVING_UNIT1 0.00 No Yes 6737.16 1.00 1184.67 0.00 177.70 177.70      
ATTIC_UNIT1 1188.55 No Yes 2955.21 1.00 148.47 0.00 0.00 0.00 0.0000   0.0000
Total 3565.64     19796.80   2517.81 0.00 355.40 355.40 0.3694 1188.55 2.1194
Conditioned Total 2377.10     10104.44   1184.67 0.00 177.70 177.70 0.5541 792.37 3.1791
Unconditioned Total 1188.55     9692.36   1333.14 0.00 177.70 177.70 0.0000   0.0000
Not Part of Total 0.00     0.00   0.00 0.00 0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2019-02-14 08:45:47

End Uses

Electricity [kBtuh] Natural Gas [kBtuh] Propane [kBtuh] District Cooling [kBtuh] Steam [kBtuh] Water [gal/min]
Time of Peak 05-SEP-18:15 12-FEB-07:15 - - - 26-MAR-08:30
Heating 0.00 2.81 0.00 0.00 0.00 0.00
Cooling 4.64 0.00 0.00 0.00 0.00 0.00
Interior Lighting 1.19 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.20 0.00 0.00 0.00 0.00 0.00
Interior Equipment 3.77 1.20 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 0.77 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 0.14 0.00 0.00 0.00 0.10
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 10.57 4.15 0.00 0.00 0.00 0.10


End Uses By Subcategory

Subcategory Electricity [kBtuh] Natural Gas [kBtuh] Propane [kBtuh] District Cooling [kBtuh] Steam [kBtuh] Water [gal/min]
Heating General 0.00 2.81 0.00 0.00 0.00 0.00
Cooling General 4.64 0.00 0.00 0.00 0.00 0.00
Interior Lighting General 1.19 0.00 0.00 0.00 0.00 0.00
Exterior Lighting Exterior-Lights 0.18 0.00 0.00 0.00 0.00 0.00
  Garage-Lights 0.03 0.00 0.00 0.00 0.00 0.00
Interior Equipment dishwasher 0.15 0.00 0.00 0.00 0.00 0.00
  refrigerator 0.31 0.00 0.00 0.00 0.00 0.00
  clotheswasher 0.04 0.00 0.00 0.00 0.00 0.00
  gas_dryer 0.03 0.53 0.00 0.00 0.00 0.00
  gas_range 0.00 0.52 0.00 0.00 0.00 0.00
  television 0.00 0.00 0.00 0.00 0.00 0.00
  gas_mels 1.62 0.15 0.00 0.00 0.00 0.00
  IECC_adj 1.62 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 0.77 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 0.14 0.00 0.00 0.00 0.00
  Domestic Hot Water 0.00 0.00 0.00 0.00 0.00 0.10
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2019-02-14 08:45:47

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [kBtu] Source Natural Gas [kBtu] Source Additional Fuel [kBtu] Source District Cooling [kBtu] Source District Heating [kBtu]
Heating 0.00 56.18 0.00 0.00 0.00
Cooling 48194.17 0.00 0.00 0.00 0.00
Interior Lighting 12814.46 0.00 0.00 0.00 0.00
Exterior Lighting 2758.33 0.00 0.00 0.00 0.00
Interior Equipment 75862.25 11939.02 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 8322.65 0.00 0.00 0.00 0.00
Pumps 249.90 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 368.11 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 148201.74 12363.31 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [kBtu/ft2] Source Natural Gas [kBtu/ft2] Source Additional Fuel [kBtu/ft2] Source District Cooling [kBtu/ft2] Source District Heating [kBtu/ft2]
Heating 0.00 0.02 0.00 0.00 0.00
Cooling 20.27 0.00 0.00 0.00 0.00
Interior Lighting 5.39 0.00 0.00 0.00 0.00
Exterior Lighting 1.16 0.00 0.00 0.00 0.00
Interior Equipment 31.91 5.02 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 3.50 0.00 0.00 0.00 0.00
Pumps 0.11 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 0.15 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 62.35 5.20 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [kBtu/ft2] Source Natural Gas [kBtu/ft2] Source Additional Fuel [kBtu/ft2] Source District Cooling [kBtu/ft2] Source District Heating [kBtu/ft2]
Heating 0.00 0.02 0.00 0.00 0.00
Cooling 20.27 0.00 0.00 0.00 0.00
Interior Lighting 5.39 0.00 0.00 0.00 0.00
Exterior Lighting 1.16 0.00 0.00 0.00 0.00
Interior Equipment 31.91 5.02 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 3.50 0.00 0.00 0.00 0.00
Pumps 0.11 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 0.15 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 62.35 5.20 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2019-02-14 08:45:47

SizingPeriod:DesignDay

Maximum Dry Bulb [F] Daily Temperature Range [deltaF] Humidity Value Humidity Type Wind Speed [ft/min] Wind Direction
HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB 61.16 0.00 61.16 Wetbulb [F] 374.03 320.00
HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB 89.96 12.78 73.94 Wetbulb [F] 1318.96 60.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2019-02-14 08:45:47

Opaque Exterior

Construction Reflectance U-Factor with Film [Btu/h-ft2-F] U-Factor no Film [Btu/h-ft2-F] Gross Area [ft2] Net Area [ft2] Azimuth [deg] Tilt [deg] Cardinal Direction
WALL_LDF_2.UNIT1 EXTERIOR WALL 0.30 0.087 0.094 338.48 294.05 180.00 90.00 S
WALL_SDR_2.UNIT1 EXTERIOR WALL 0.30 0.087 0.094 253.86 209.43 90.00 90.00 E
WALL_LDB_2.UNIT1 EXTERIOR WALL 0.30 0.087 0.094 338.48 294.05 0.00 90.00 N
WALL_SDL_2.UNIT1 EXTERIOR WALL 0.30 0.087 0.094 253.86 209.43 270.00 90.00 W
WALL_LDF_1.UNIT1 EXTERIOR WALL 0.30 0.087 0.094 338.48 294.05 180.00 90.00 S
WALL_SDR_1.UNIT1 EXTERIOR WALL 0.30 0.087 0.094 253.86 209.43 90.00 90.00 E
WALL_LDB_1.UNIT1 EXTERIOR WALL 0.30 0.087 0.094 338.48 254.03 0.00 90.00 N
WALL_SDL_1.UNIT1 EXTERIOR WALL 0.30 0.087 0.094 253.86 209.43 270.00 90.00 W
ROOF_RIGHT_UNIT1 GABLE_END 0.30 0.314 0.428 74.24 74.24 90.00 90.00 E
ROOF_LEFT_UNIT1 GABLE_END 0.30 0.314 0.428 74.24 74.24 270.00 90.00 W
ROOF_FRONT_UNIT1 EXTERIOR ROOF 0.25 0.543 0.943 626.38 626.38 180.00 18.42  
ROOF_BACK_UNIT1 EXTERIOR ROOF 0.25 0.543 0.943 626.38 626.38 0.00 18.42  


Exterior Fenestration

Construction Glass Area [ft2] Frame Area [ft2] Divider Area [ft2] Area of One Opening [ft2] Area of Multiplied Openings [ft2] Glass U-Factor [Btu/h-ft2-F] Glass SHGC Glass Visible Transmittance Frame Conductance [Btu/h-ft2-F] Divider Conductance [Btu/h-ft2-F] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
WINDOW_LDF_2.UNIT1 EXTERIOR WINDOW 44.43 0.00 0.00 44.43 44.43 0.501 0.330 0.882     Yes WALL_LDF_2.UNIT1 180.00 90.00 S
WINDOW_SDR_2.UNIT1 EXTERIOR WINDOW 44.43 0.00 0.00 44.43 44.43 0.501 0.330 0.882     Yes WALL_SDR_2.UNIT1 90.00 90.00 E
WINDOW_LDB_2.UNIT1 EXTERIOR WINDOW 44.43 0.00 0.00 44.43 44.43 0.501 0.330 0.882     Yes WALL_LDB_2.UNIT1 0.00 90.00 N
WINDOW_SDL_2.UNIT1 EXTERIOR WINDOW 44.43 0.00 0.00 44.43 44.43 0.501 0.330 0.882     Yes WALL_SDL_2.UNIT1 270.00 90.00 W
WINDOW_LDF_1.UNIT1 EXTERIOR WINDOW 44.43 0.00 0.00 44.43 44.43 0.501 0.330 0.882     Yes WALL_LDF_1.UNIT1 180.00 90.00 S
WINDOW_SDR_1.UNIT1 EXTERIOR WINDOW 44.43 0.00 0.00 44.43 44.43 0.501 0.330 0.882     Yes WALL_SDR_1.UNIT1 90.00 90.00 E
WINDOW_LDB_1.UNIT1 EXTERIOR WINDOW 44.43 0.00 0.00 44.43 44.43 0.501 0.330 0.882     Yes WALL_LDB_1.UNIT1 0.00 90.00 N
WINDOW_SDL_1.UNIT1 EXTERIOR WINDOW 44.43 0.00 0.00 44.43 44.43 0.501 0.330 0.882     Yes WALL_SDL_1.UNIT1 270.00 90.00 W
Total or Average           355.40 0.501 0.330 0.882              
North Total or Average           88.85 0.501 0.330 0.882              
Non-North Total or Average           266.55 0.501 0.330 0.882              


Interior Fenestration

Construction Area of One Opening [ft2] Area of Openings [ft2] Glass U-Factor [Btu/h-ft2-F] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [Btu/h-ft2-F] U-Factor no Film [Btu/h-ft2-F] Gross Area [ft2] Parent Surface
DOOR_LDB_UNIT1 EXTERIOR DOOR 0.351 0.500 40.02 WALL_LDB_1.UNIT1



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2019-02-14 08:45:47

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
WINDOW_LDF_2.UNIT1 1.00 1.00 1.00 0.00 0.00 0.00 1.00 1.00 1.00
WINDOW_SDR_2.UNIT1 0.99 0.95 0.00 0.99 0.92 0.00 0.99 0.94 0.00
WINDOW_LDB_2.UNIT1 0.00 0.00 0.00 1.00 1.00 1.00 0.00 0.00 0.00
WINDOW_SDL_2.UNIT1 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
WINDOW_LDF_1.UNIT1 1.00 1.00 1.00 0.00 0.00 0.00 1.00 1.00 1.00
WINDOW_SDR_1.UNIT1 0.99 0.95 0.00 0.99 0.92 0.00 0.99 0.94 0.00
WINDOW_LDB_1.UNIT1 0.00 0.00 0.00 1.00 1.00 1.00 0.00 0.00 0.00
WINDOW_SDL_1.UNIT1 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00


Window Control

Name Type Shaded Construction Control Glare Control
WINDOW_LDF_2.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No
WINDOW_SDR_2.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No
WINDOW_LDB_2.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No
WINDOW_SDL_2.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No
WINDOW_LDF_1.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No
WINDOW_SDR_1.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No
WINDOW_LDB_1.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No
WINDOW_SDL_1.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2019-02-14 08:45:47

Interior Lighting

Zone Lighting Power Density [Btu/h-ft2] Zone Area [ft2] Total Power [Btu/h] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [kWh]
LIVING HARDWIRED LIGHTING1 LIVING_UNIT1 0.4024 2377.10 956.57 General INTERIORLIGHTINGHE 58.88 168.00 58.88 0.0000 Y 860.69
LIVING PLUG-IN LIGHTING1 LIVING_UNIT1 0.1517 2377.10 360.49 General INTERIORLIGHTINGHE 58.88 168.00 58.88 0.0000 Y 324.36
UNCOND LIVING HARDWIRED LIGHTING1 UNCOND_LIVING_UNIT1 0.0000 0.00 0.00 General INTERIORLIGHTINGHE 58.88 0.00   0.0000 N 0.00
UNCOND LIVING PLUG-IN LIGHTING1 UNCOND_LIVING_UNIT1 0.0000 0.00 0.00 General INTERIORLIGHTINGHE 58.88 0.00   0.0000 N 0.00
Interior Lighting Total   0.2770 4754.19 1317.06               1185.05


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [Btu/h] Lighting Controlled [Btu/h]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [kWh]
EXTERIOR-LIGHTS_UNIT1 52.18 Schedule EXTERIORLIGHTING 84.00 84.00 84.00 228.55
GARAGE-LIGHTS_UNIT1 8.64 Schedule INTERIORLIGHTINGHE 58.88 168.00 58.88 26.54
Exterior Lighting Total 60.82           255.08



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2019-02-14 08:45:47

Central Plant

Type Nominal Capacity [Btu/h] Nominal Efficiency [Btuh/Btuh] IPLV in SI Units [Btuh/Btuh] IPLV in IP Units [Btu/W-h]
None          


Cooling Coils

Type Design Coil Load [Btu/h] Nominal Total Capacity [Btu/h] Nominal Sensible Capacity [Btu/h] Nominal Latent Capacity [Btu/h] Nominal Sensible Heat Ratio Nominal Efficiency [Btuh/Btuh] Nominal Coil UA Value [Btu/h-F] Nominal Coil Surface Area [ft2]
DX COOLING COIL_UNIT1 Coil:Cooling:DX:SingleSpeed   21224.15 15292.85 5931.29 0.72 4.07    
Nominal values are gross at rated conditions, i.e., the supply air fan heat and electric power NOT accounted for.

DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [ton] Standard Rated Net COP [Btuh/Btuh] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
DX COOLING COIL_UNIT1   1.7 3.41 11.63 12.33 12.09
ANSI/AHRI ratings account for supply air fan heat and electric power.

DX Cooling Coil ASHRAE 127 Standard Ratings Report

DX Cooling Coil Type Rated Net Cooling Capacity Test A [ton] Rated Electric Power Test A [W] Rated Net Cooling Capacity Test B [ton] Rated Electric Power Test B [W] Rated Net Cooling Capacity Test C [ton] Rated Electric Power Test C [W] Rated Net Cooling Capacity Test D [ton] Rated Electric Power Test D [W]
DX COOLING COIL_UNIT1 Coil:Cooling:DX:SingleSpeed                


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [Btu/h] Low Temperature Heating (net) Rating Capacity [Btu/h] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [Btu/h] Nominal Total Capacity [Btu/h] Nominal Efficiency [Btuh/Btuh]
MAIN FUEL HEATING COIL_UNIT1 Coil:Heating:Fuel   3951.03 0.80


Fans

Type Total Efficiency [Btuh/Btuh] Delta Pressure [psi] Max Air Flow Rate [ft3/min] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-min/ft3] Motor Heat In Air Fraction End Use
SUPPLY FAN_UNIT1 Fan:OnOff 0.50 0.06 626.98 236.49 0.38 1.00 General


Pumps

Type Control Head [psi] Water Flow [gal/min] Electric Power [W] Power Per Water Flow Rate [W-min/gal] Motor Efficiency [Btuh/Btuh]
MAINS PRESSURE_UNIT1 Pump:VariableSpeed Intermittent 0.00 7.827838 0.00 0.00 1.00
COLLECTOR LOOP PUMP Pump:VariableSpeed Intermittent 43.51 0.317040 8.84 27.89 0.87


Service Water Heating

Type Storage Volume [ft3] Input [Btu/h] Thermal Efficiency [Btuh/Btuh] Recovery Efficiency [Btuh/Btuh] Energy Factor
INSTANTANEOUS WATER HEATER WaterHeater:Mixed 0.20 272960.00 0.80 446.30 0.80
STORAGE TANK WaterHeater:Mixed 52.98 0.00 0.80 0.00 0.00



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2019-02-14 08:45:47

Zone Sensible Cooling

Calculated Design Load [Btu/h] User Design Load [Btu/h] User Design Load per Area [Btu/h-ft2] Calculated Design Air Flow [ft3/min] User Design Air Flow [ft3/min] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [F] Indoor Temperature at Peak Load [F] Indoor Humidity Ratio at Peak Load [lbWater/lbAir] Outdoor Temperature at Peak Load [F] Outdoor Humidity Ratio at Peak Load [lbWater/lbAir] Minimum Outdoor Air Flow Rate [ft3/min] Heat Gain Rate from DOAS [Btu/h]
LIVING_UNIT1 14723.89 14723.89 6.19 626.984 626.984 HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB 8/21 17:45:00 74.98 74.98 0.00962 87.21 0.01435 59.993 0.00
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

Zone Sensible Heating

Calculated Design Load [Btu/h] User Design Load [Btu/h] User Design Load per Area [Btu/h-ft2] Calculated Design Air Flow [ft3/min] User Design Air Flow [ft3/min] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [F] Indoor Temperature at Peak Load [F] Indoor Humidity Ratio at Peak Load [lbWater/lbAir] Outdoor Temperature at Peak Load [F] Outdoor Humidity Ratio at Peak Load [lbWater/lbAir] Minimum Outdoor Air Flow Rate [ft3/min] Heat Gain Rate from DOAS [Btu/h]
LIVING_UNIT1 2153.69 2153.69 0.91 39.213 59.993 HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB 2/21 14:00:00 72.00 72.00 0.01108 61.16 0.01152 59.993 0.00
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

System Design Air Flow Rates

Calculated cooling [ft3/min] User cooling [ft3/min] Calculated heating [ft3/min] User heating [ft3/min]
CENTRAL SYSTEM_UNIT1 626.98 626.98 59.99 59.99


Plant Loop Coincident Design Fluid Flow Rate Adjustments

Previous Design Volume Flow Rate [ft3/min] Algorithm Volume Flow Rate [ft3/min] Coincident Design Volume Flow Rate [ft3/min] Coincident Size Adjusted Peak Sizing Period Name Peak Day into Period {TIMESTAMP}[day] Peak Hour Of Day {TIMESTAMP}[hr] Peak Step Start Minute {TIMESTAMP}[min]
None                



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2019-02-14 08:45:47

Economizer

High Limit Shutoff Control Minimum Outdoor Air [ft3/min] Maximum Outdoor Air [ft3/min] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [F] Outdoor Air Enthalpy Limit [F]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [ft3/min-person] Outdoor Air Per Area [ft3/min-ft2] Outdoor Air Per Zone [ft3/min] Outdoor Air ACH [ACH] Outdoor Air Method Outdoor Air Schedule Name Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule Name
None                    


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
LIVING_UNIT1 8033.50 2988.25 2634.50
UNCOND_LIVING_UNIT1 0.00 0.00 0.00
ATTIC_UNIT1 0.00 0.00 0.00
Facility 8033.50 2988.25 2634.50
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
LIVING_UNIT1 0.00 0.00 0.00 0.00
UNCOND_LIVING_UNIT1 0.00 0.00 0.00 0.00
ATTIC_UNIT1 0.00 0.00 0.00 0.00
Facility 0.00 0.00 0.00 0.00
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2019-02-14 08:45:47

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [ft3] Mechanical Ventilation [ACH] Infiltration [ACH] AFN Infiltration [ACH] Simple Ventilation [ACH]
LIVING_UNIT1 2.07 3.00 10104.44 0.000 0.584 0.000 0.355
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [ft3] Mechanical Ventilation [ACH] Infiltration [ACH] AFN Infiltration [ACH] Simple Ventilation [ACH]
LIVING_UNIT1 2.07 3.00 10104.44 0.000 0.000 0.000 0.007
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2019-02-14 08:45:47

Surfaces by Class

Total Outdoors
Wall 10 10
Floor 3 0
Roof 3 2
Internal Mass 1 0
Building Detached Shading 0 0
Fixed Detached Shading 4 4
Window 8 8
Door 1 1
Glass Door 0 0
Shading 4 4
Overhang 2 2
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 1
Conditioned Zones 1
Unconditioned Zones 2
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 413
Defaulted Fields 53
Fields with Defaults 1277
Autosized Fields 20
Autosizable Fields 29
Autocalculated Fields 13
Autocalculatable Fields 35



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2019-02-14 08:45:47

Annual and Peak Values - Electricity

Electricity Annual Value [kWh] Electricity Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Electricity Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
Electricity:Facility 13705.30 701.85 04-JAN-04:00 3096.11 05-SEP-18:15
Electricity:Building 8200.59 649.08 02-JAN-03:15 1559.40 01-JAN-20:15
Electricity:Zone:LIVING_UNIT1 8200.59 649.08 02-JAN-03:15 1559.40 01-JAN-20:15
InteriorLights:Electricity 1185.05 26.54 01-JAN-00:15 386.01 01-JAN-19:15
InteriorLights:Electricity:Zone:LIVING_UNIT1 1185.05 26.54 01-JAN-00:15 386.01 01-JAN-19:15
General:InteriorLights:Electricity 1185.05 26.54 01-JAN-00:15 386.01 01-JAN-19:15
Electricity:Zone:UNCOND_LIVING_UNIT1 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
InteriorLights:Electricity:Zone:UNCOND_LIVING_UNIT1 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
InteriorEquipment:Electricity 7015.54 601.94 02-JAN-04:15 1173.39 01-JAN-20:15
InteriorEquipment:Electricity:Zone:LIVING_UNIT1 7015.54 601.94 02-JAN-04:15 1173.39 01-JAN-20:15
dishwasher:InteriorEquipment:Electricity 184.69 1.69 02-JAN-03:15 58.93 01-JAN-19:15
refrigerator:InteriorEquipment:Electricity 668.67 66.60 01-JAN-04:15 91.06 01-JAN-18:15
clotheswasher:InteriorEquipment:Electricity 94.32 0.91 02-JAN-02:15 25.55 01-JAN-09:15
gas_dryer:InteriorEquipment:Electricity 75.94 0.39 02-JAN-03:15 19.42 01-JAN-11:15
gas_range:InteriorEquipment:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
television:InteriorEquipment:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
gas_mels:InteriorEquipment:Electricity 3001.13 262.21 01-JAN-09:15 507.15 01-JAN-20:15
IECC_adj:InteriorEquipment:Electricity 2990.78 261.30 01-JAN-09:15 505.40 01-JAN-20:15
InteriorEquipment:Electricity:Zone:UNCOND_LIVING_UNIT1 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity 769.66 0.00 01-JAN-01:30 236.49 03-SEP-16:45
Fans:Electricity:Zone:LIVING_UNIT1 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 13705.30 701.85 04-JAN-04:00 3096.11 05-SEP-18:15
ElectricityPurchased:Plant 13705.30 701.85 04-JAN-04:00 3096.11 05-SEP-18:15
Cogeneration:ElectricityPurchased 13705.30 701.85 04-JAN-04:00 3096.11 05-SEP-18:15
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 13705.30 701.85 04-JAN-04:00 3096.11 05-SEP-18:15
ElectricityNet:Plant 13705.30 701.85 04-JAN-04:00 3096.11 05-SEP-18:15
Cogeneration:ElectricityNet 13705.30 701.85 04-JAN-04:00 3096.11 05-SEP-18:15
ExteriorLights:Electricity 255.08 1.11 01-JAN-09:15 60.82 01-JAN-19:15
Exterior-Lights:ExteriorLights:Electricity 228.55 0.00 01-JAN-06:15 52.18 01-JAN-00:15
Garage-Lights:ExteriorLights:Electricity 26.54 0.59 01-JAN-00:15 8.64 01-JAN-19:15
Electricity:HVAC 5226.52 0.00 01-JAN-01:30 1699.18 03-SEP-15:45
General:Fans:Electricity 769.66 0.00 01-JAN-01:30 236.49 03-SEP-16:45
Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:Electricity 4456.87 0.00 01-JAN-01:30 1463.95 03-SEP-13:00
Electricity:Plant 23.11 0.00 01-JAN-00:15 8.84 01-JAN-08:45
Pumps:Electricity 23.11 0.00 01-JAN-00:15 8.84 01-JAN-08:45


Annual and Peak Values - Gas

Gas Annual Value [therm] Gas Minimum Value [Btu/h] Timestamp of Minimum {TIMESTAMP} Gas Maximum Value [Btu/h] Timestamp of Maximum {TIMESTAMP}
Gas:Facility 114.05 187.90 08-SEP-03:30 4150.52 12-FEB-07:15
Gas:Building 110.14 184.05 02-JAN-03:15 2927.62 01-JAN-17:15
Gas:Zone:LIVING_UNIT1 110.14 184.05 02-JAN-03:15 2927.62 01-JAN-17:15
InteriorEquipment:Gas 110.14 184.05 02-JAN-03:15 2927.62 01-JAN-17:15
InteriorEquipment:Gas:Zone:LIVING_UNIT1 110.14 184.05 02-JAN-03:15 2927.62 01-JAN-17:15
gas_dryer:InteriorEquipment:Gas 52.83 26.91 02-JAN-03:15 1349.77 01-JAN-11:15
gas_range:InteriorEquipment:Gas 44.96 43.46 01-JAN-02:15 1845.69 01-JAN-17:15
gas_mels:InteriorEquipment:Gas 12.35 107.83 01-JAN-09:15 208.56 01-JAN-20:15
Gas:Plant 3.40 0.00 01-JAN-00:15 553.85 04-MAR-09:00
WaterSystems:Gas 3.40 0.00 01-JAN-00:15 553.85 04-MAR-09:00
Water Heater:WaterSystems:Gas 3.40 0.00 01-JAN-00:15 553.85 04-MAR-09:00
Gas:HVAC 0.52 0.00 01-JAN-00:15 3168.57 12-FEB-07:00
Heating:Gas 0.52 0.00 01-JAN-00:15 3168.57 12-FEB-07:00


Annual and Peak Values - Cooling

Cooling Annual Value [ton-hrs] Cooling Minimum Value [ton] Timestamp of Minimum {TIMESTAMP} Cooling Maximum Value [ton] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Water

Annual Value [ft3] Minimum Value [ft3/min] Timestamp of Minimum {TIMESTAMP} Maximum Value [ft3/min] Timestamp of Maximum {TIMESTAMP}
Water:Facility 3537.61 0.00 02-JAN-03:00 0.01 26-MAR-08:30
Water:Plant 3537.61 0.00 02-JAN-03:00 0.01 26-MAR-08:30
WaterSystems:Water 3537.61 0.00 02-JAN-03:00 0.01 26-MAR-08:30
Water Heater:WaterSystems:Water 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
MainsWater:Facility 3537.61 0.00 02-JAN-03:00 0.01 26-MAR-08:30
MainsWater:Plant 3537.61 0.00 02-JAN-03:00 0.01 26-MAR-08:30
WaterSystems:MainsWater 3537.61 0.00 02-JAN-03:00 0.01 26-MAR-08:30
Water Heater:WaterSystems:MainsWater 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Domestic Hot Water:WaterSystems:Water 3537.61 0.00 02-JAN-03:00 0.01 26-MAR-08:30
Domestic Hot Water:WaterSystems:MainsWater 3537.61 0.00 02-JAN-03:00 0.01 26-MAR-08:30


Annual and Peak Values - Other by Weight/Mass

Annual Value [lb] Minimum Value [lb/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [lb/s] Timestamp of Maximum {TIMESTAMP}
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [ft3] Minimum Value [ft3/min] Timestamp of Minimum {TIMESTAMP} Maximum Value [ft3/min] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [gal] Minimum Value [gal] Timestamp of Minimum {TIMESTAMP} Maximum Value [gal] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Other

Annual Value [kBtu] Minimum Value [Btu/h] Timestamp of Minimum {TIMESTAMP} Maximum Value [Btu/h] Timestamp of Maximum {TIMESTAMP}
PlantLoopHeatingDemand:Facility 19502.55 53.55 25-JUL-02:15 12205.08 29-JAN-12:30
PlantLoopHeatingDemand:Plant 19502.55 53.55 25-JUL-02:15 12205.08 29-JAN-12:30
WaterSystems:PlantLoopHeatingDemand 19502.55 53.55 25-JUL-02:15 12205.08 29-JAN-12:30
Water Heater:WaterSystems:PlantLoopHeatingDemand 13842.01 0.00 01-JAN-00:15 11341.67 29-JAN-12:30
EnergyTransfer:Facility 114926.78 56.78 23-MAY-03:00 36662.46 05-SEP-17:30
EnergyTransfer:Building 43288.24 0.00 01-JAN-01:30 14869.95 03-SEP-16:30
EnergyTransfer:Zone:LIVING_UNIT1 43288.24 0.00 01-JAN-01:30 14869.95 03-SEP-16:30
Heating:EnergyTransfer 49.94 0.00 01-JAN-00:15 3052.55 12-FEB-07:00
Heating:EnergyTransfer:Zone:LIVING_UNIT1 49.94 0.00 01-JAN-00:15 3052.55 12-FEB-07:00
Cooling:EnergyTransfer 43238.30 0.00 01-JAN-01:30 14869.95 03-SEP-16:30
Cooling:EnergyTransfer:Zone:LIVING_UNIT1 43238.30 0.00 01-JAN-01:30 14869.95 03-SEP-16:30
EnergyTransfer:Zone:UNCOND_LIVING_UNIT1 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:UNCOND_LIVING_UNIT1 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:UNCOND_LIVING_UNIT1 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:ATTIC_UNIT1 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:ATTIC_UNIT1 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:ATTIC_UNIT1 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Plant 5660.55 53.55 25-JUL-02:15 1369.33 22-JAN-08:15
WaterSystems:EnergyTransfer 5660.55 53.55 25-JUL-02:15 1369.33 22-JAN-08:15
Domestic Hot Water:WaterSystems:EnergyTransfer 5660.55 53.55 25-JUL-02:15 1369.33 22-JAN-08:15
EnergyTransfer:HVAC 65977.99 0.00 01-JAN-01:30 21432.14 04-SEP-16:30
HeatingCoils:EnergyTransfer 41.46 0.00 01-JAN-00:15 2534.86 12-FEB-07:00
CoolingCoils:EnergyTransfer 65936.53 0.00 01-JAN-01:30 21432.14 04-SEP-16:30
SolarWater:Facility 13773.14 -389.3 24-MAY-15:15 11440.75 09-DEC-11:30
SolarWater:Plant 13773.14 -389.3 24-MAY-15:15 11440.75 09-DEC-11:30
HeatProduced:SolarWater 13773.14 -389.3 24-MAY-15:15 11440.75 09-DEC-11:30



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2019-02-14 08:45:47

Annual Building Sensible Heat Gain Components

HVAC Zone Eq & Other Sensible Air Heating [kBtu] HVAC Zone Eq & Other Sensible Air Cooling [ton-hrs] HVAC Terminal Unit Sensible Air Heating [kBtu] HVAC Terminal Unit Sensible Air Cooling [ton-hrs] HVAC Input Heated Surface Heating [kBtu] HVAC Input Cooled Surface Cooling [ton-hrs] People Sensible Heat Addition [kBtu] Lights Sensible Heat Addition [kBtu] Equipment Sensible Heat Addition [kBtu] Window Heat Addition [kBtu] Interzone Air Transfer Heat Addition [kBtu] Infiltration Heat Addition [kBtu] Opaque Surface Conduction and Other Heat Addition [kBtu] Equipment Sensible Heat Removal [kBtu] Window Heat Removal [kBtu] Interzone Air Transfer Heat Removal [kBtu] Infiltration Heat Removal [kBtu] Opaque Surface Conduction and Other Heat Removal [kBtu]
LIVING_UNIT1 0.000 0.000 49.939 -3600.77 0.000 0.000 4334.254 4046.244 21742.330 13363.514 0.000 5667.655 0.000 0.000 -1385.93 0.000 -1685.30 -2894.55
UNCOND_LIVING_UNIT1 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 9085.561 0.000 0.000 0.108 0.000 -4707.74 0.000 0.000 -4377.82
ATTIC_UNIT1 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 633.732 5908.111 0.000 0.000 0.000 -6541.84 -0.05
Total Facility 0.000 0.000 49.939 -3600.77 0.000 0.000 4334.254 4046.244 21742.330 22449.075 0.000 6301.387 5908.219 0.000 -6093.67 0.000 -8227.14 -7272.42


Peak Cooling Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [Btu/h] HVAC Zone Eq & Other Sensible Air Cooling [ton] HVAC Terminal Unit Sensible Air Heating [Btu/h] HVAC Terminal Unit Sensible Air Cooling [ton] HVAC Input Heated Surface Heating [Btu/h] HVAC Input Cooled Surface Cooling [ton] People Sensible Heat Addition [Btu/h] Lights Sensible Heat Addition [Btu/h] Equipment Sensible Heat Addition [Btu/h] Window Heat Addition [Btu/h] Interzone Air Transfer Heat Addition [Btu/h] Infiltration Heat Addition [Btu/h] Opaque Surface Conduction and Other Heat Addition [Btu/h] Equipment Sensible Heat Removal [Btu/h] Window Heat Removal [Btu/h] Interzone Air Transfer Heat Removal [Btu/h] Infiltration Heat Removal [Btu/h] Opaque Surface Conduction and Other Heat Removal [Btu/h]
LIVING_UNIT1 03-SEP-16:19 0.00 0.00 0.00 -1.2 0.00 0.00 208.13 633.84 3066.00 4617.85 0.00 3380.85 2986.81 0.00 0.00 0.00 0.00 0.00
UNCOND_LIVING_UNIT1 - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
ATTIC_UNIT1 - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 03-SEP-16:19 0.00 0.00 0.00 -1.2 0.00 0.00 208.13 633.84 3066.00 6756.57 0.00 3380.85 3165.75 0.00 0.00 0.00 -2317.7 0.00


Peak Heating Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [Btu/h] HVAC Zone Eq & Other Sensible Air Cooling [ton] HVAC Terminal Unit Sensible Air Heating [Btu/h] HVAC Terminal Unit Sensible Air Cooling [ton] HVAC Input Heated Surface Heating [Btu/h] HVAC Input Cooled Surface Cooling [ton] People Sensible Heat Addition [Btu/h] Lights Sensible Heat Addition [Btu/h] Equipment Sensible Heat Addition [Btu/h] Window Heat Addition [Btu/h] Interzone Air Transfer Heat Addition [Btu/h] Infiltration Heat Addition [Btu/h] Opaque Surface Conduction and Other Heat Addition [Btu/h] Equipment Sensible Heat Removal [Btu/h] Window Heat Removal [Btu/h] Interzone Air Transfer Heat Removal [Btu/h] Infiltration Heat Removal [Btu/h] Opaque Surface Conduction and Other Heat Removal [Btu/h]
LIVING_UNIT1 12-FEB-07:00 0.00 0.00 3052.47 0.00 0.00 0.00 789.46 633.84 2231.34 0.00 0.00 0.00 0.00 0.00 -1286.8 0.00 -2629.5 -2790.8
UNCOND_LIVING_UNIT1 - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
ATTIC_UNIT1 - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 12-FEB-07:00 0.00 0.00 3052.47 0.00 0.00 0.00 789.46 633.84 2231.34 0.00 0.00 216.38 0.00 0.00 -1882.1 0.00 -2629.5 -2411.8



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2019-02-14 08:45:47

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [ft3/min] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [ft3/min] System Primary Airflow - Vps [ft3/min] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [ft3/min] Percent Outdoor Air - %OA
CENTRAL SYSTEM_UNIT1 626.984 3.00 3.00 1.00 59.9933 626.984 0.096 1.000 59.9933 0.10


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [ft3/min] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [ft3/min] System Primary Airflow - Vps [ft3/min] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [ft3/min] Percent Outdoor Air - %OA
CENTRAL SYSTEM_UNIT1 59.993 3.00 3.00 1.00 59.9933 59.993 1.000 1.000 59.9933 1.00


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [ft3/min-person] Zone Population - Pz Area Outdoor Air Rate - Ra [ft3/min-ft2] Zone Floor Area - Az [ft2] Breathing Zone Outdoor Airflow - Vbz [ft3/min] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [ft3/min] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [ft3/min]
LIVING_UNIT1 CENTRAL SYSTEM_UNIT1 0.000000 3.00 0.000000 2377.10 59.9933 1.000 59.9933 1.000 59.9933


System Ventilation Parameters

People Outdoor Air Rate - Rp [ft3/min-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [ft3/min-ft2] Sum of Zone Floor Area - Az-sum [ft2] Breathing Zone Outdoor Airflow - Vbz [ft3/min] Cooling Zone Outdoor Airflow - Voz-clg [ft3/min] Heating Zone Outdoor Airflow - Voz-htg [ft3/min]
CENTRAL SYSTEM_UNIT1 0.000000 3.00 0.000000 2377.10 59.9933 59.9933 59.9933


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [ft3/min] Zone Discharge Airflow - Vdz [ft3/min] Minimum Zone Primary Airflow - Vpz-min [ft3/min] Zone Outdoor Airflow Cooling - Voz-clg [ft3/min] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
LIVING_UNIT1 CENTRAL SYSTEM_UNIT1   626.984 626.9839 356.4898 59.9933 0.000 1.000 0.000 0.000 0.000 0.000 1.000


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [ft3/min] System Primary Airflow - Vps [ft3/min] Sum of Zone Discharge Airflow - Vdz-sum [ft3/min] Sum of Min Zone Primary Airflow - Vpz-min [ft3/min] Zone Outdoor Airflow Cooling - Voz-clg [ft3/min] Zone Ventilation Efficiency - Evz-min
CENTRAL SYSTEM_UNIT1 626.98 626.984 626.98 356.4898 59.9933 1.000


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [ft3/min] Zone Discharge Airflow - Vdz [ft3/min] Minimum Zone Primary Airflow - Vpz-min [ft3/min] Zone Outdoor Airflow Heating - Voz-htg [ft3/min] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
LIVING_UNIT1 CENTRAL SYSTEM_UNIT1   59.993 59.993 59.993 59.9933 1.000 1.000 0.000 0.000 0.000 0.000 1.000


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [ft3/min] System Primary Airflow - Vps [ft3/min] Sum of Zone Discharge Airflow - Vdz-sum [ft3/min] Sum of Min Zone Primary Airflow - Vpz-min [ft3/min] Zone Outdoor Airflow Heating - Voz-htg [ft3/min] Zone Ventilation Efficiency - Evz-min
CENTRAL SYSTEM_UNIT1 59.99 59.993 59.99 59.99 59.9933 1.000



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2019-02-14 08:45:47

Sec1.1A-General Information

Data
Weather File ANNUAL ** Honolulu Intl Arpt HI USA TMY3 WMO#=911820
Total gross floor area [ft2] 3565.64
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [ft2] Regularly Occupied Area [ft2] Unconditioned Area [ft2] Typical Hours/Week in Operation [hr/wk]
LIVING_UNIT1 2377.10 2377.10 0.00 168.00
UNCOND_LIVING_UNIT1 0.00 0.00 0.00 0.00
ATTIC_UNIT1 1188.55 0.00 1188.55 0.00
Totals 3565.64 2377.10 1188.55  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 0.00
Number of hours cooling loads not met 0.00
Number of hours not met 0.00


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [kWh] Electric Demand [W] Natural Gas Energy Use [therm] Natural Gas Demand [Btu/h] Additional Energy Use [kBtu] Additional Demand [Btu/h]
Interior Lighting 1185.05 348.31 0.00 0.00 0.00 0.00
Exterior Lighting 255.08 59.98 0.00 0.00 0.00 0.00
Space Heating 0.00 0.00 0.52 2810.14 0.00 0.00
Space Cooling 4456.87 1358.07 0.00 0.00 0.00 0.00
Pumps 23.11 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Fans-Interior 769.66 225.30 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 0.00 0.00 3.40 141.42 0.00 0.00
Receptacle Equipment 7015.54 1104.44 110.14 1198.96 0.00 0.00
Interior Lighting-Process 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 13705.30   114.05   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [kBtu] Total Energy Use [kBtu]
Electricity 23953.98 46795.62
Natural Gas 11013.86 11405.27
Additional 0.00 0.00
Total 34967.83 58200.90


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [kBtu]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [kWh/ft2]
Interior Lighting 0.33
Space Heating 0.00
Space Cooling 1.25
Fans-Interior 0.22
Service Water Heating 0.00
Receptacle Equipment 1.97
Miscellaneous 0.08
Subtotal 3.84


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [kWh/ft2]
Space Heating 0.00
Service Water Heating 0.03
Miscellaneous 0.90
Subtotal 0.94


EAp2-17c. Energy Use Intensity - Additional

Additional [kBtu/ft2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 6.95
Space Heating 0.09
Space Cooling 26.15
Fans-Interior 4.52
Service Water Heating 0.58
Receptacle Equipment 60.08
Miscellaneous 1.63



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2019-02-14 08:45:47

AirTerminal:SingleDuct:Uncontrolled

Design Size Maximum Air Flow Rate [ft3/min]
ZONEDIRECTAIR_UNIT1 626.98
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

AirLoopHVAC

Design Supply Air Flow Rate [ft3/min]
CENTRAL SYSTEM_UNIT1 626.98
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Cooling:DX:SingleSpeed

Design Size Rated Air Flow Rate [ft3/min] Design Size Gross Rated Total Cooling Capacity [ton] Design Size Gross Rated Sensible Heat Ratio
DX COOLING COIL_UNIT1 626.98 1.77 0.720540
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

AirLoopHVAC:UnitaryHeatCool

Supply Air Flow Rate [ft3/min] Supply Air Flow Rate During Heating Operation [ft3/min] Supply Air Flow Rate During Cooling Operation [ft3/min] Nominal Heating Capacity [Btu/h] Nominal Cooling Capacity [ton] Fraction of Supply Air Flow That Goes Through the Controlling Zone
ACANDF_UNIT1 626.98 626.98 626.98 3951.03 1.77 1.00
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Fan:OnOff

Design Size Maximum Flow Rate [ft3/min]
SUPPLY FAN_UNIT1 626.98
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Heating:Fuel

Design Size Nominal Capacity [Btu/h]
MAIN FUEL HEATING COIL_UNIT1 3951.03
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

PlantLoop

Maximum Loop Flow Rate [ft3/min] Plant Loop Volume [ft3]
DHW LOOP_SOLAR 1.05 19.62
COLLECTOR LOOP 0.042373 0.794696
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Pump:VariableSpeed

Design Flow Rate [ft3/min] Design Power Consumption [Btu/h]
MAINS PRESSURE_UNIT1 1.05  
COLLECTOR LOOP PUMP 0.042373 30.17
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

WaterHeater:Mixed

Use Side Design Flow Rate [ft3/min] Source Side Design Flow Rate [ft3/min]
STORAGE TANK 1.05 0.042373
INSTANTANEOUS WATER HEATER 1.05  
User-Specified values were used. Design Size values were used if no User-Specified values were provided.


Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2019-02-14 08:45:47

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

Possible Shadow Receivers
COLLECTOR SURFACE 1 ROOF_FRONT_UNIT1 |
Mir-COLLECTOR SURFACE 1 ROOF_FRONT_UNIT1 |
COLLECTOR SURFACE 2 ROOF_FRONT_UNIT1 |
Mir-COLLECTOR SURFACE 2 ROOF_FRONT_UNIT1 |
OVERHANG_SDR_1.UNIT1 WALL_SDR_1.UNIT1 |
Mir-OVERHANG_SDR_1.UNIT1 Mir-COLLECTOR SURFACE 1 | Mir-COLLECTOR SURFACE 2 | OVERHANG_SDR_2.UNIT1 | WALL_SDR_2.UNIT1 | WALL_SDR_1.UNIT1 | ROOF_RIGHT_UNIT1 |
OVERHANG_SDR_2.UNIT1 WALL_SDR_2.UNIT1 |
Mir-OVERHANG_SDR_2.UNIT1 Mir-COLLECTOR SURFACE 1 | Mir-COLLECTOR SURFACE 2 | WALL_SDR_2.UNIT1 | ROOF_RIGHT_UNIT1 |
WALL_SDR_2.UNIT1 OVERHANG_SDR_2.UNIT1 |
WALL_SDR_1.UNIT1 OVERHANG_SDR_1.UNIT1 | OVERHANG_SDR_2.UNIT1 |
ROOF_FRONT_UNIT1 COLLECTOR SURFACE 1 | Mir-COLLECTOR SURFACE 1 | COLLECTOR SURFACE 2 | Mir-COLLECTOR SURFACE 2 |


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
WALL_LDF_2.UNIT1 WINDOW_LDF_2.UNIT1 |
WALL_SDR_2.UNIT1 WINDOW_SDR_2.UNIT1 |
WALL_LDB_2.UNIT1 WINDOW_LDB_2.UNIT1 |
WALL_SDL_2.UNIT1 WINDOW_SDL_2.UNIT1 |
WALL_LDF_1.UNIT1 WINDOW_LDF_1.UNIT1 |
WALL_SDR_1.UNIT1 WINDOW_SDR_1.UNIT1 |
WALL_LDB_1.UNIT1 WINDOW_LDB_1.UNIT1 | DOOR_LDB_UNIT1 |
WALL_SDL_1.UNIT1 WINDOW_SDL_1.UNIT1 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2019-02-14 08:45:47

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: FANSPLIT

For: CENTRAL SYSTEM_UNIT1

Timestamp: 2019-02-14 08:45:47

Custom Monthly Report

AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] AIR SYSTEM FAN ELECTRIC ENERGY {FOR HOURS SHOWN} [kWh] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY {HOURS NON-ZERO} [HOURS] AIR SYSTEM FAN ELECTRIC ENERGY {FOR HOURS SHOWN} [kWh] AIR SYSTEM FAN ELECTRIC ENERGY [kWh]
January 537.162 38.574 6.000 0.103 38.677
February 505.241 41.027 22.792 1.450 42.477
March 574.183 46.820 27.875 0.862 47.682
April 619.389 48.257 0.000 0.000 48.257
May 718.200 65.534 0.000 0.000 65.534
June 720.000 76.070 0.000 0.000 76.070
July 744.000 90.185 0.000 0.000 90.185
August 744.000 90.680 0.000 0.000 90.680
September 720.000 87.639 0.000 0.000 87.639
October 725.375 74.265 0.000 0.000 74.265
November 660.023 58.981 4.250 0.040 59.021
December 641.759 49.144 3.750 0.025 49.170
           
Annual Sum or Average 7909.332 767.176 64.667 2.480 769.656
Minimum of Months 505.241 38.574 0.000 0.000 38.677
Maximum of Months 744.000 90.680 27.875 1.450 90.680



Table of Contents

Report: COILLOADS

For: MAIN FUEL HEATING COIL_UNIT1

Timestamp: 2019-02-14 08:45:47

Custom Monthly Report

HEATING COIL TOTAL HEATING RATE [Invalid/Undefined] HEATING COIL AIR HEATING RATE [Btu/h] COOLING COIL TOTAL COOLING RATE [Invalid/Undefined]
January 0.00 2.31 0.00
February 0.00 36.05 0.00
March 0.00 19.35 0.00
April 0.00 0.00 0.00
May 0.00 0.00 0.00
June 0.00 0.00 0.00
July 0.00 0.00 0.00
August 0.00 0.00 0.00
September 0.00 0.00 0.00
October 0.00 0.00 0.00
November 0.00 0.93 0.00
December 0.00 0.57 0.00
       
Annual Sum or Average 0.00 4.73 0.00
Minimum of Months 0.00 0.00 0.00
Maximum of Months 0.00 36.05 0.00



Table of Contents

Report: COILLOADS

For: DX COOLING COIL_UNIT1

Timestamp: 2019-02-14 08:45:47

Custom Monthly Report

HEATING COIL TOTAL HEATING RATE [Invalid/Undefined] HEATING COIL AIR HEATING RATE [Invalid/Undefined] COOLING COIL TOTAL COOLING RATE [ton]
January 0.00 0.00 0.36
February 0.00 0.00 0.44
March 0.00 0.00 0.44
April 0.00 0.00 0.47
May 0.00 0.00 0.62
June 0.00 0.00 0.76
July 0.00 0.00 0.88
August 0.00 0.00 0.88
September 0.00 0.00 0.89
October 0.00 0.00 0.71
November 0.00 0.00 0.59
December 0.00 0.00 0.47
       
Annual Sum or Average 0.00 0.00 0.63
Minimum of Months 0.00 0.00 0.36
Maximum of Months 0.00 0.00 0.89



Table of Contents

Report: WATER HEATER: LOADS

For: INSTANTANEOUS WATER HEATER

Timestamp: 2019-02-14 08:45:47

Custom Monthly Report

WATER HEATER TOTAL DEMAND RATE [Invalid/Undefined] WATER HEATER TOTAL DEMAND ENERGY [Invalid/Undefined] WATER HEATER HEATING RATE [Btu/h] WATER HEATER HEATING ENERGY [kBtu]
January 0.00 0.00 35.59 26.50
February 0.00 0.00 45.37 30.51
March 0.00 0.00 39.41 29.34
April 0.00 0.00 35.95 25.90
May 0.00 0.00 30.06 22.38
June 0.00 0.00 33.23 23.94
July 0.00 0.00 35.67 26.56
August 0.00 0.00 21.21 15.79
September 0.00 0.00 22.20 16.00
October 0.00 0.00 19.87 14.79
November 0.00 0.00 21.84 15.73
December 0.00 0.00 32.54 24.23
         
Annual Sum or Average 0.00 0.00 30.99 271.67
Minimum of Months 0.00 0.00 19.87 14.79
Maximum of Months 0.00 0.00 45.37 30.51



Table of Contents

Report: WATER HEATER: LOADS

For: STORAGE TANK

Timestamp: 2019-02-14 08:45:47

Custom Monthly Report

WATER HEATER TOTAL DEMAND RATE [Invalid/Undefined] WATER HEATER TOTAL DEMAND ENERGY [Invalid/Undefined] WATER HEATER HEATING RATE [Btu/h] WATER HEATER HEATING ENERGY [kBtu]
January 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00
         
Annual Sum or Average 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00