Table of Contents

Program Version:EnergyPlus, Version 8.6.0-Unknown, YMD=2019.02.14 08:52

Tabular Output Report in Format: HTML

Building: SF+CZ3CWH+USA_CA_San.Francisco.Intl.AP.724940+hp+crawlspace+IECC_2009

Environment: ANNUAL ** San Francisco Intl Ap CA USA TMY3 WMO#=724940

Simulation Timestamp: 2019-02-14 08:52:14


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2019-02-14 08:52:14

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [kBtu] Energy Per Total Building Area [kBtu/ft2] Energy Per Conditioned Building Area [kBtu/ft2]
Total Site Energy 58669.66 12.34 24.68
Net Site Energy 58669.66 12.34 24.68
Total Source Energy 185806.83 39.08 78.17
Net Source Energy 185806.83 39.08 78.17


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [ft2]
Total Building Area 4754.19
Net Conditioned Building Area 2377.10
Unconditioned Building Area 2377.10


End Uses

Electricity [kBtu] Natural Gas [kBtu] Additional Fuel [kBtu] District Cooling [kBtu] District Heating [kBtu] Water [gal]
Heating 10792.66 0.00 0.00 0.00 0.00 0.00
Cooling 1549.44 0.00 0.00 0.00 0.00 0.00
Interior Lighting 4565.60 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 1024.88 0.00 0.00 0.00 0.00 0.00
Interior Equipment 26605.68 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 2121.13 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 12010.29 0.00 0.00 0.00 0.00 29497.56
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 58669.66 0.00 0.00 0.00 0.00 29497.56
Note: Electricity appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [kBtu] Natural Gas [kBtu] Additional Fuel [kBtu] District Cooling [kBtu] District Heating [kBtu] Water [gal]
Heating General 10792.66 0.00 0.00 0.00 0.00 0.00
Cooling General 1549.44 0.00 0.00 0.00 0.00 0.00
Interior Lighting General 4565.60 0.00 0.00 0.00 0.00 0.00
Exterior Lighting Exterior-Lights 918.27 0.00 0.00 0.00 0.00 0.00
  Garage-Lights 106.61 0.00 0.00 0.00 0.00 0.00
Interior Equipment dishwasher 703.03 0.00 0.00 0.00 0.00 0.00
  refrigerator 2283.13 0.00 0.00 0.00 0.00 0.00
  clotheswasher 359.04 0.00 0.00 0.00 0.00 0.00
  electric_dryer 2845.15 0.00 0.00 0.00 0.00 0.00
  electric_range 2062.62 0.00 0.00 0.00 0.00 0.00
  television 0.00 0.00 0.00 0.00 0.00 0.00
  electric_mels 11465.79 0.00 0.00 0.00 0.00 0.00
  IECC_adj 6886.92 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 2121.13 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 12010.29 0.00 0.00 0.00 0.00 0.00
  Domestic Hot Water 0.00 0.00 0.00 0.00 0.00 29497.56
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [kBtu/ft2] Natural Gas Intensity [kBtu/ft2] Additional Fuel Intensity [kBtu/ft2] District Cooling Intensity [kBtu/ft2] District Heating Intensity [kBtu/ft2] Water Intensity [gal/ft2]
Lighting 2.35 0.00 0.00 0.00 0.00 0.00
HVAC 11.14 0.00 0.00 0.00 0.00 12.41
Other 11.19 0.00 0.00 0.00 0.00 0.00
Total 24.68 0.00 0.00 0.00 0.00 12.41


Utility Use Per Total Floor Area

Electricity Intensity [kBtu/ft2] Natural Gas Intensity [kBtu/ft2] Additional Fuel Intensity [kBtu/ft2] District Cooling Intensity [kBtu/ft2] District Heating Intensity [kBtu/ft2] Water Intensity [gal/ft2]
Lighting 1.18 0.00 0.00 0.00 0.00 0.00
HVAC 5.57 0.00 0.00 0.00 0.00 6.20
Other 5.60 0.00 0.00 0.00 0.00 0.00
Total 12.34 0.00 0.00 0.00 0.00 6.20


Electric Loads Satisfied

Electricity [kBtu] Percent Electricity [%]
Fuel-Fired Power Generation 0.000 0.00
High Temperature Geothermal* 0.000 0.00
Photovoltaic Power 0.000 0.00
Wind Power 0.000 0.00
Power Conversion 0.000 0.00
Net Decrease in On-Site Storage 0.000 0.00
Total On-Site Electric Sources 0.000 0.00
     
Electricity Coming From Utility 58669.665 100.00
Surplus Electricity Going To Utility 0.000 0.00
Net Electricity From Utility 58669.665 100.00
     
Total On-Site and Utility Electric Sources 58669.665 100.00
Total Electricity End Uses 58669.665 100.00


On-Site Thermal Sources

Heat [kBtu] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [gal] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 29497.56 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 29497.56 100.00
Total Water End Uses 29497.56 100.00


Setpoint Not Met Criteria

Degrees [deltaF]
Tolerance for Zone Heating Setpoint Not Met Time 0.36
Tolerance for Zone Cooling Setpoint Not Met Time 0.36


Comfort and Setpoint Not Met Summary

Facility [Hours]
Time Setpoint Not Met During Occupied Heating 0.00
Time Setpoint Not Met During Occupied Cooling 5.50
Time Not Comfortable Based on Simple ASHRAE 55-2004 68.00


Note 1: An asterisk (*) indicates that the feature is not yet implemented.

Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Adaptive Comfort Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

FANSPLIT

| CENTRAL SYSTEM_UNIT1 |

COILLOADS

| MAIN DX HEATING COIL_UNIT1 | SUPP HEATING COIL_UNIT1 | DX COOLING COIL_UNIT1 |

WATER HEATER: LOADS

| WATER HEATER_UNIT1 |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2019-02-14 08:52:14

General

Value
Program Version and Build EnergyPlus, Version 8.6.0-Unknown, YMD=2019.02.14 08:52
RunPeriod ANNUAL
Weather File San Francisco Intl Ap CA USA TMY3 WMO#=724940
Latitude [deg] 37.62
Longitude [deg] -122.4
Elevation [ft] 6.56
Time Zone -8.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [ft2] 2781.72 756.60 634.26 756.60 634.26
Above Ground Wall Area [ft2] 2572.66 696.86 589.47 696.86 589.47
Window Opening Area [ft2] 355.40 88.85 88.85 88.85 88.85
Gross Window-Wall Ratio [%] 12.78 11.74 14.01 11.74 14.01
Above Ground Window-Wall Ratio [%] 13.81 12.75 15.07 12.75 15.07


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [ft2] 2369.34 676.95 507.72 676.95 507.72
Above Ground Wall Area [ft2] 2369.34 676.95 507.72 676.95 507.72
Window Opening Area [ft2] 355.40 88.85 88.85 88.85 88.85
Gross Window-Wall Ratio [%] 15.00 13.12 17.50 13.12 17.50
Above Ground Window-Wall Ratio [%] 15.00 13.12 17.50 13.12 17.50


Skylight-Roof Ratio

Total
Gross Roof Area [ft2] 1240.82
Skylight Area [ft2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [ft2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [ft3] Multipliers Above Ground Gross Wall Area [ft2] Underground Gross Wall Area [ft2] Window Glass Area [ft2] Opening Area [ft2] Lighting [Btu/h-ft2] People [ft2 per person] Plug and Process [Btu/h-ft2]
LIVING_UNIT1 2377.10 Yes Yes 16644.74 1.00 2369.34 0.00 355.40 355.40 0.6252 792.37 2.2317
ATTIC_UNIT1 1188.55 No Yes 2659.93 1.00 133.64 0.00 0.00 0.00 0.0000   0.0000
CRAWLSPACE_UNIT1 1188.55 No Yes 2377.82 1.00 69.69 209.06 0.00 0.00 0.0000   0.0000
Total 4754.19     21682.49   2572.66 209.06 355.40 355.40 0.3126 1584.73 1.1158
Conditioned Total 2377.10     16644.74   2369.34 0.00 355.40 355.40 0.6252 792.37 2.2317
Unconditioned Total 2377.10     5037.75   203.32 209.06 0.00 0.00 0.0000   0.0000
Not Part of Total 0.00     0.00   0.00 0.00 0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2019-02-14 08:52:14

End Uses

Electricity [kBtuh] Natural Gas [kBtuh] Propane [kBtuh] District Cooling [kBtuh] Steam [kBtuh] Water [gal/min]
Time of Peak 27-DEC-06:45 - - - - 25-MAR-08:45
Heating 10.37 0.00 0.00 0.00 0.00 0.00
Cooling 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 0.72 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.02 0.00 0.00 0.00 0.00 0.00
Interior Equipment 2.65 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 0.87 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 6.94 0.00 0.00 0.00 0.00 0.11
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 21.56 0.00 0.00 0.00 0.00 0.11


End Uses By Subcategory

Subcategory Electricity [kBtuh] Natural Gas [kBtuh] Propane [kBtuh] District Cooling [kBtuh] Steam [kBtuh] Water [gal/min]
Heating General 10.37 0.00 0.00 0.00 0.00 0.00
Cooling General 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting General 0.72 0.00 0.00 0.00 0.00 0.00
Exterior Lighting Exterior-Lights 0.00 0.00 0.00 0.00 0.00 0.00
  Garage-Lights 0.02 0.00 0.00 0.00 0.00 0.00
Interior Equipment dishwasher 0.04 0.00 0.00 0.00 0.00 0.00
  refrigerator 0.24 0.00 0.00 0.00 0.00 0.00
  clotheswasher 0.02 0.00 0.00 0.00 0.00 0.00
  electric_dryer 0.12 0.00 0.00 0.00 0.00 0.00
  electric_range 0.14 0.00 0.00 0.00 0.00 0.00
  television 0.00 0.00 0.00 0.00 0.00 0.00
  electric_mels 1.31 0.00 0.00 0.00 0.00 0.00
  IECC_adj 0.79 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 0.87 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 6.94 0.00 0.00 0.00 0.00 0.00
  Domestic Hot Water 0.00 0.00 0.00 0.00 0.00 0.11
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2019-02-14 08:52:14

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [kBtu] Source Natural Gas [kBtu] Source Additional Fuel [kBtu] Source District Cooling [kBtu] Source District Heating [kBtu]
Heating 34180.35 0.00 0.00 0.00 0.00
Cooling 4907.07 0.00 0.00 0.00 0.00
Interior Lighting 14459.26 0.00 0.00 0.00 0.00
Exterior Lighting 3245.80 0.00 0.00 0.00 0.00
Interior Equipment 84260.19 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 6717.60 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 38036.57 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 185806.83 0.00 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [kBtu/ft2] Source Natural Gas [kBtu/ft2] Source Additional Fuel [kBtu/ft2] Source District Cooling [kBtu/ft2] Source District Heating [kBtu/ft2]
Heating 14.38 0.00 0.00 0.00 0.00
Cooling 2.06 0.00 0.00 0.00 0.00
Interior Lighting 6.08 0.00 0.00 0.00 0.00
Exterior Lighting 1.37 0.00 0.00 0.00 0.00
Interior Equipment 35.45 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 2.83 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 16.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 78.17 0.00 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [kBtu/ft2] Source Natural Gas [kBtu/ft2] Source Additional Fuel [kBtu/ft2] Source District Cooling [kBtu/ft2] Source District Heating [kBtu/ft2]
Heating 14.38 0.00 0.00 0.00 0.00
Cooling 2.06 0.00 0.00 0.00 0.00
Interior Lighting 6.08 0.00 0.00 0.00 0.00
Exterior Lighting 1.37 0.00 0.00 0.00 0.00
Interior Equipment 35.45 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 2.83 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 16.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 78.17 0.00 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2019-02-14 08:52:14

SizingPeriod:DesignDay

Maximum Dry Bulb [F] Daily Temperature Range [deltaF] Humidity Value Humidity Type Wind Speed [ft/min] Wind Direction
SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 38.84 0.00 38.84 Wetbulb [F] 433.09 150.00
SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 82.94 15.30 62.96 Wetbulb [F] 1161.47 310.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2019-02-14 08:52:14

Opaque Exterior

Construction Reflectance U-Factor with Film [Btu/h-ft2-F] U-Factor no Film [Btu/h-ft2-F] Gross Area [ft2] Net Area [ft2] Azimuth [deg] Tilt [deg] Cardinal Direction
WALL_LDF_1.UNIT1 EXTERIOR WALL 0.30 0.087 0.094 338.48 294.05 180.00 90.00 S
WALL_SDR_1.UNIT1 EXTERIOR WALL 0.30 0.087 0.094 253.86 209.43 90.00 90.00 E
WALL_LDB_1.UNIT1 EXTERIOR WALL 0.30 0.087 0.094 338.48 254.03 0.00 90.00 N
WALL_SDL_1.UNIT1 EXTERIOR WALL 0.30 0.087 0.094 253.86 209.43 270.00 90.00 W
WALL_LDF_2.UNIT1 EXTERIOR WALL 0.30 0.087 0.094 338.48 294.05 180.00 90.00 S
WALL_SDR_2.UNIT1 EXTERIOR WALL 0.30 0.087 0.094 253.86 209.43 90.00 90.00 E
WALL_LDB_2.UNIT1 EXTERIOR WALL 0.30 0.087 0.094 338.48 294.05 0.00 90.00 N
WALL_SDL_2.UNIT1 EXTERIOR WALL 0.30 0.087 0.094 253.86 209.43 270.00 90.00 W
ROOF_RIGHT_UNIT1 GABLE_END 0.30 0.314 0.428 66.82 66.82 90.00 90.00 E
ROOF_LEFT_UNIT1 GABLE_END 0.30 0.314 0.428 66.82 66.82 270.00 90.00 W
ROOF_FRONT_UNIT1 EXTERIOR ROOF 0.25 0.543 0.943 620.41 620.41 180.00 16.69  
ROOF_BACK_UNIT1 EXTERIOR ROOF 0.25 0.543 0.943 620.41 620.41 0.00 16.69  
BGWALL_UPPER_LDF CRAWL WALL 0.30 0.776 2.276 19.91 19.91 180.00 90.00 S
BGWALL_LOWER_LDF CRAWL WALL 0.30 0.893 2.276 59.73 59.73 180.00 90.00 S
BGWALL_UPPER_SDR CRAWL WALL 0.30 0.776 2.276 14.93 14.93 90.00 90.00 E
BGWALL_LOWER_SDR CRAWL WALL 0.30 0.893 2.276 44.80 44.80 90.00 90.00 E
BGWALL_UPPER_LDB CRAWL WALL 0.30 0.776 2.276 19.91 19.91 0.00 90.00 N
BGWALL_LOWER_LDB CRAWL WALL 0.30 0.893 2.276 59.73 59.73 0.00 90.00 N
BGWALL_UPPER_SDL CRAWL WALL 0.30 0.776 2.276 14.93 14.93 270.00 90.00 W
BGWALL_LOWER_SDL CRAWL WALL 0.30 0.893 2.276 44.80 44.80 270.00 90.00 W
EXTFLOOR_UNIT1 INTERIOR FLOOR 0.30 0.235 0.300 1188.55 1188.55 90.00 180.00  


Exterior Fenestration

Construction Glass Area [ft2] Frame Area [ft2] Divider Area [ft2] Area of One Opening [ft2] Area of Multiplied Openings [ft2] Glass U-Factor [Btu/h-ft2-F] Glass SHGC Glass Visible Transmittance Frame Conductance [Btu/h-ft2-F] Divider Conductance [Btu/h-ft2-F] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
WINDOW_LDF_1.UNIT1 EXTERIOR WINDOW 44.43 0.00 0.00 44.43 44.43 0.501 0.258 0.882     Yes WALL_LDF_1.UNIT1 180.00 90.00 S
WINDOW_SDR_1.UNIT1 EXTERIOR WINDOW 44.43 0.00 0.00 44.43 44.43 0.501 0.258 0.882     Yes WALL_SDR_1.UNIT1 90.00 90.00 E
WINDOW_LDB_1.UNIT1 EXTERIOR WINDOW 44.43 0.00 0.00 44.43 44.43 0.501 0.258 0.882     Yes WALL_LDB_1.UNIT1 0.00 90.00 N
WINDOW_SDL_1.UNIT1 EXTERIOR WINDOW 44.43 0.00 0.00 44.43 44.43 0.501 0.258 0.882     Yes WALL_SDL_1.UNIT1 270.00 90.00 W
WINDOW_LDF_2.UNIT1 EXTERIOR WINDOW 44.43 0.00 0.00 44.43 44.43 0.501 0.258 0.882     Yes WALL_LDF_2.UNIT1 180.00 90.00 S
WINDOW_SDR_2.UNIT1 EXTERIOR WINDOW 44.43 0.00 0.00 44.43 44.43 0.501 0.258 0.882     Yes WALL_SDR_2.UNIT1 90.00 90.00 E
WINDOW_LDB_2.UNIT1 EXTERIOR WINDOW 44.43 0.00 0.00 44.43 44.43 0.501 0.258 0.882     Yes WALL_LDB_2.UNIT1 0.00 90.00 N
WINDOW_SDL_2.UNIT1 EXTERIOR WINDOW 44.43 0.00 0.00 44.43 44.43 0.501 0.258 0.882     Yes WALL_SDL_2.UNIT1 270.00 90.00 W
Total or Average           355.40 0.501 0.258 0.882              
North Total or Average           88.85 0.501 0.258 0.882              
Non-North Total or Average           266.55 0.501 0.258 0.882              


Interior Fenestration

Construction Area of One Opening [ft2] Area of Openings [ft2] Glass U-Factor [Btu/h-ft2-F] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [Btu/h-ft2-F] U-Factor no Film [Btu/h-ft2-F] Gross Area [ft2] Parent Surface
DOOR_LDB_UNIT1 EXTERIOR DOOR 0.351 0.500 40.02 WALL_LDB_1.UNIT1



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2019-02-14 08:52:14

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
WINDOW_LDF_1.UNIT1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
WINDOW_SDR_1.UNIT1 0.99 0.91 0.00 0.99 0.78 0.00 1.00 0.79 0.00
WINDOW_LDB_1.UNIT1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
WINDOW_SDL_1.UNIT1 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
WINDOW_LDF_2.UNIT1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
WINDOW_SDR_2.UNIT1 0.99 0.91 0.00 0.99 0.78 0.00 1.00 0.79 0.00
WINDOW_LDB_2.UNIT1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
WINDOW_SDL_2.UNIT1 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00


Window Control

Name Type Shaded Construction Control Glare Control
WINDOW_LDF_1.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No
WINDOW_SDR_1.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No
WINDOW_LDB_1.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No
WINDOW_SDL_1.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No
WINDOW_LDF_2.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No
WINDOW_SDR_2.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No
WINDOW_LDB_2.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No
WINDOW_SDL_2.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2019-02-14 08:52:14

Interior Lighting

Zone Lighting Power Density [Btu/h-ft2] Zone Area [ft2] Total Power [Btu/h] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [kWh]
LIVING HARDWIRED LIGHTING1 LIVING_UNIT1 0.4735 2377.10 1125.62 General INTERIORLIGHTINGHE 58.88 168.00 58.88 0.0000 Y 1012.80
LIVING PLUG-IN LIGHTING1 LIVING_UNIT1 0.1517 2377.10 360.49 General INTERIORLIGHTINGHE 58.88 168.00 58.88 0.0000 Y 324.36
Interior Lighting Total   0.3126 4754.19 1486.12               1337.15


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [Btu/h] Lighting Controlled [Btu/h]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [kWh]
EXTERIOR-LIGHTS_UNIT1 61.40 Schedule EXTERIORLIGHTING 84.00 84.00 84.00 268.94
GARAGE-LIGHTS_UNIT1 10.17 Schedule INTERIORLIGHTINGHE 58.88 168.00 58.88 31.22
Exterior Lighting Total 71.57           300.16



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2019-02-14 08:52:14

Central Plant

Type Nominal Capacity [Btu/h] Nominal Efficiency [Btuh/Btuh] IPLV in SI Units [Btuh/Btuh] IPLV in IP Units [Btu/W-h]
None          


Cooling Coils

Type Design Coil Load [Btu/h] Nominal Total Capacity [Btu/h] Nominal Sensible Capacity [Btu/h] Nominal Latent Capacity [Btu/h] Nominal Sensible Heat Ratio Nominal Efficiency [Btuh/Btuh] Nominal Coil UA Value [Btu/h-F] Nominal Coil Surface Area [ft2]
DX COOLING COIL_UNIT1 Coil:Cooling:DX:SingleSpeed   18095.02 14451.69 3643.34 0.80 4.07    
Nominal values are gross at rated conditions, i.e., the supply air fan heat and electric power NOT accounted for.

DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [ton] Standard Rated Net COP [Btuh/Btuh] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
DX COOLING COIL_UNIT1   1.4 3.26 11.11 11.62 10.86
ANSI/AHRI ratings account for supply air fan heat and electric power.

DX Cooling Coil ASHRAE 127 Standard Ratings Report

DX Cooling Coil Type Rated Net Cooling Capacity Test A [ton] Rated Electric Power Test A [W] Rated Net Cooling Capacity Test B [ton] Rated Electric Power Test B [W] Rated Net Cooling Capacity Test C [ton] Rated Electric Power Test C [W] Rated Net Cooling Capacity Test D [ton] Rated Electric Power Test D [W]
DX COOLING COIL_UNIT1 Coil:Cooling:DX:SingleSpeed                


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [Btu/h] Low Temperature Heating (net) Rating Capacity [Btu/h] HSPF [Btu/W-h] Region Number
MAIN DX HEATING COIL_UNIT1 Coil:Heating:DX:SingleSpeed 18962.3 10560.9 7.85 4
ANSI/AHRI ratings account for supply air fan heat and electric power.

Heating Coils

Type Design Coil Load [Btu/h] Nominal Total Capacity [Btu/h] Nominal Efficiency [Btuh/Btuh]
MAIN DX HEATING COIL_UNIT1 Coil:Heating:DX:SingleSpeed   18095.02 3.69
SUPP HEATING COIL_UNIT1 Coil:Heating:Electric   19895.68 1.00
Nominal values are gross at rated conditions, i.e., the supply air fan heat and electric power NOT accounted for.

Fans

Type Total Efficiency [Btuh/Btuh] Delta Pressure [psi] Max Air Flow Rate [ft3/min] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-min/ft3] Motor Heat In Air Fraction End Use
SUPPLY FAN_UNIT1 Fan:OnOff 0.50 0.06 678.76 256.02 0.38 1.00 General


Pumps

Type Control Head [psi] Water Flow [gal/min] Electric Power [W] Power Per Water Flow Rate [W-min/gal] Motor Efficiency [Btuh/Btuh]
MAINS PRESSURE_UNIT1 Pump:VariableSpeed Intermittent 0.00 7.827838 0.00 0.00 1.00


Service Water Heating

Type Storage Volume [ft3] Input [Btu/h] Thermal Efficiency [Btuh/Btuh] Recovery Efficiency [Btuh/Btuh] Energy Factor
WATER HEATER_UNIT1 WaterHeater:Mixed 6.95 18766.00 1.00 1.05 0.95



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2019-02-14 08:52:14

Zone Sensible Cooling

Calculated Design Load [Btu/h] User Design Load [Btu/h] User Design Load per Area [Btu/h-ft2] Calculated Design Air Flow [ft3/min] User Design Air Flow [ft3/min] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [F] Indoor Temperature at Peak Load [F] Indoor Humidity Ratio at Peak Load [lbWater/lbAir] Outdoor Temperature at Peak Load [F] Outdoor Humidity Ratio at Peak Load [lbWater/lbAir] Minimum Outdoor Air Flow Rate [ft3/min] Heat Gain Rate from DOAS [Btu/h]
LIVING_UNIT1 15943.93 15943.93 6.71 678.761 678.761 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 17:00:00 74.98 74.98 0.00803 80.80 0.00771 59.993 0.00
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

Zone Sensible Heating

Calculated Design Load [Btu/h] User Design Load [Btu/h] User Design Load per Area [Btu/h-ft2] Calculated Design Air Flow [ft3/min] User Design Air Flow [ft3/min] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [F] Indoor Temperature at Peak Load [F] Indoor Humidity Ratio at Peak Load [lbWater/lbAir] Outdoor Temperature at Peak Load [F] Outdoor Humidity Ratio at Peak Load [lbWater/lbAir] Minimum Outdoor Air Flow Rate [ft3/min] Heat Gain Rate from DOAS [Btu/h]
LIVING_UNIT1 18005.30 18005.30 7.57 327.742 327.742 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 14:00:00 72.00 71.99 0.00693 38.84 0.00496 59.993 0.00
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

System Design Air Flow Rates

Calculated cooling [ft3/min] User cooling [ft3/min] Calculated heating [ft3/min] User heating [ft3/min]
CENTRAL SYSTEM_UNIT1 678.76 678.76 327.74 327.74


Plant Loop Coincident Design Fluid Flow Rate Adjustments

Previous Design Volume Flow Rate [ft3/min] Algorithm Volume Flow Rate [ft3/min] Coincident Design Volume Flow Rate [ft3/min] Coincident Size Adjusted Peak Sizing Period Name Peak Day into Period {TIMESTAMP}[day] Peak Hour Of Day {TIMESTAMP}[hr] Peak Step Start Minute {TIMESTAMP}[min]
None                



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2019-02-14 08:52:14

Economizer

High Limit Shutoff Control Minimum Outdoor Air [ft3/min] Maximum Outdoor Air [ft3/min] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [F] Outdoor Air Enthalpy Limit [F]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [ft3/min-person] Outdoor Air Per Area [ft3/min-ft2] Outdoor Air Per Zone [ft3/min] Outdoor Air ACH [ACH] Outdoor Air Method Outdoor Air Schedule Name Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule Name
None                    


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
LIVING_UNIT1 972.00 7182.75 68.00
ATTIC_UNIT1 0.00 0.00 0.00
CRAWLSPACE_UNIT1 0.00 0.00 0.00
Facility 972.00 7182.75 68.00
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
LIVING_UNIT1 0.00 5.50 0.00 5.50
ATTIC_UNIT1 0.00 0.00 0.00 0.00
CRAWLSPACE_UNIT1 0.00 0.00 0.00 0.00
Facility 0.00 5.50 0.00 5.50
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2019-02-14 08:52:14

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [ft3] Mechanical Ventilation [ACH] Infiltration [ACH] AFN Infiltration [ACH] Simple Ventilation [ACH]
LIVING_UNIT1 2.07 3.00 16644.74 0.000 0.603 0.000 0.223
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [ft3] Mechanical Ventilation [ACH] Infiltration [ACH] AFN Infiltration [ACH] Simple Ventilation [ACH]
LIVING_UNIT1 2.07 3.00 16644.74 0.000 0.001 0.000 0.004
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2019-02-14 08:52:14

Surfaces by Class

Total Outdoors
Wall 18 18
Floor 4 1
Roof 4 2
Internal Mass 1 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 8 8
Door 1 1
Glass Door 0 0
Shading 4 4
Overhang 2 2
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 1
Conditioned Zones 1
Unconditioned Zones 2
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 378
Defaulted Fields 51
Fields with Defaults 1259
Autosized Fields 18
Autosizable Fields 25
Autocalculated Fields 20
Autocalculatable Fields 50



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2019-02-14 08:52:14

Annual and Peak Values - Electricity

Electricity Annual Value [kWh] Electricity Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Electricity Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
Electricity:Facility 17182.92 705.18 24-SEP-01:15 6314.35 27-DEC-06:45
Electricity:Building 9129.31 605.67 02-JAN-03:15 1730.72 01-JAN-18:15
Electricity:Zone:LIVING_UNIT1 9129.31 605.67 02-JAN-03:15 1730.72 01-JAN-18:15
InteriorLights:Electricity 1337.15 29.94 01-JAN-00:15 435.56 01-JAN-19:15
InteriorLights:Electricity:Zone:LIVING_UNIT1 1337.15 29.94 01-JAN-00:15 435.56 01-JAN-19:15
General:InteriorLights:Electricity 1337.15 29.94 01-JAN-00:15 435.56 01-JAN-19:15
InteriorEquipment:Electricity 7792.16 567.10 02-JAN-04:15 1337.70 01-JAN-18:15
InteriorEquipment:Electricity:Zone:LIVING_UNIT1 7792.16 567.10 02-JAN-04:15 1337.70 01-JAN-18:15
dishwasher:InteriorEquipment:Electricity 205.90 1.89 02-JAN-03:15 65.70 01-JAN-19:15
refrigerator:InteriorEquipment:Electricity 668.67 66.60 01-JAN-04:15 91.06 01-JAN-18:15
clotheswasher:InteriorEquipment:Electricity 105.15 1.01 02-JAN-02:15 28.48 01-JAN-09:15
electric_dryer:InteriorEquipment:Electricity 833.27 4.25 02-JAN-03:15 213.06 01-JAN-11:15
electric_range:InteriorEquipment:Electricity 604.09 5.84 01-JAN-02:15 248.15 01-JAN-17:15
television:InteriorEquipment:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
electric_mels:InteriorEquipment:Electricity 3358.05 293.39 01-JAN-09:15 567.46 01-JAN-20:15
IECC_adj:InteriorEquipment:Electricity 2017.01 176.23 01-JAN-09:15 340.85 01-JAN-20:15
Electricity:Plant 3517.52 0.00 01-JAN-00:15 2112.31 05-FEB-08:15
WaterSystems:Electricity 3517.52 0.00 01-JAN-00:15 2112.31 05-FEB-08:15
Water Heater:WaterSystems:Electricity 3517.52 0.00 01-JAN-00:15 2112.31 05-FEB-08:15
Fans:Electricity 621.23 0.00 01-JAN-13:45 256.02 01-JAN-04:45
Fans:Electricity:Zone:LIVING_UNIT1 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 17182.92 705.18 24-SEP-01:15 6314.35 27-DEC-06:45
ElectricityPurchased:Plant 17182.92 705.18 24-SEP-01:15 6314.35 27-DEC-06:45
Cogeneration:ElectricityPurchased 17182.92 705.18 24-SEP-01:15 6314.35 27-DEC-06:45
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 17182.92 705.18 24-SEP-01:15 6314.35 27-DEC-06:45
ElectricityNet:Plant 17182.92 705.18 24-SEP-01:15 6314.35 27-DEC-06:45
Cogeneration:ElectricityNet 17182.92 705.18 24-SEP-01:15 6314.35 27-DEC-06:45
ExteriorLights:Electricity 300.16 1.31 01-JAN-09:15 71.57 01-JAN-19:15
Exterior-Lights:ExteriorLights:Electricity 268.94 0.00 01-JAN-06:15 61.40 01-JAN-00:15
Garage-Lights:ExteriorLights:Electricity 31.22 0.70 01-JAN-00:15 10.17 01-JAN-19:15
Electricity:HVAC 4235.93 0.00 01-JAN-13:45 3527.83 24-JAN-06:00
General:Fans:Electricity 621.23 0.00 01-JAN-13:45 256.02 01-JAN-04:45
Cooling:Electricity 453.79 0.00 01-JAN-00:15 1238.39 30-JUN-14:00
Heating:Electricity 3160.91 0.00 01-JAN-13:45 3271.81 24-JAN-06:00
Pumps:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15


Annual and Peak Values - Gas

Gas Annual Value [therm] Gas Minimum Value [Btu/h] Timestamp of Minimum {TIMESTAMP} Gas Maximum Value [Btu/h] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Cooling

Cooling Annual Value [ton-hrs] Cooling Minimum Value [ton] Timestamp of Minimum {TIMESTAMP} Cooling Maximum Value [ton] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Water

Annual Value [ft3] Minimum Value [ft3/min] Timestamp of Minimum {TIMESTAMP} Maximum Value [ft3/min] Timestamp of Maximum {TIMESTAMP}
Water:Facility 3943.83 0.00 02-JAN-02:15 0.01 25-MAR-08:45
Water:Plant 3943.83 0.00 02-JAN-02:15 0.01 25-MAR-08:45
WaterSystems:Water 3943.83 0.00 02-JAN-02:15 0.01 25-MAR-08:45
Water Heater:WaterSystems:Water 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
MainsWater:Facility 3943.83 0.00 02-JAN-02:15 0.01 25-MAR-08:45
MainsWater:Plant 3943.83 0.00 02-JAN-02:15 0.01 25-MAR-08:45
WaterSystems:MainsWater 3943.83 0.00 02-JAN-02:15 0.01 25-MAR-08:45
Water Heater:WaterSystems:MainsWater 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Domestic Hot Water:WaterSystems:Water 3943.83 0.00 02-JAN-02:15 0.01 25-MAR-08:45
Domestic Hot Water:WaterSystems:MainsWater 3943.83 0.00 02-JAN-02:15 0.01 25-MAR-08:45


Annual and Peak Values - Other by Weight/Mass

Annual Value [lb] Minimum Value [lb/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [lb/s] Timestamp of Maximum {TIMESTAMP}
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [ft3] Minimum Value [ft3/min] Timestamp of Minimum {TIMESTAMP} Maximum Value [ft3/min] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [gal] Minimum Value [gal] Timestamp of Minimum {TIMESTAMP} Maximum Value [gal] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Other

Annual Value [kBtu] Minimum Value [Btu/h] Timestamp of Minimum {TIMESTAMP} Maximum Value [Btu/h] Timestamp of Maximum {TIMESTAMP}
PlantLoopHeatingDemand:Facility 11108.96 110.54 07-AUG-03:00 2585.38 05-FEB-08:45
PlantLoopHeatingDemand:Plant 11108.96 110.54 07-AUG-03:00 2585.38 05-FEB-08:45
WaterSystems:PlantLoopHeatingDemand 11108.96 110.54 07-AUG-03:00 2585.38 05-FEB-08:45
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 97285.14 187.36 24-SEP-01:15 40065.65 22-DEC-05:00
EnergyTransfer:Building 43512.14 0.00 01-JAN-13:45 20324.31 22-DEC-05:00
EnergyTransfer:Zone:LIVING_UNIT1 43512.14 0.00 01-JAN-13:45 20324.31 22-DEC-05:00
Heating:EnergyTransfer 37434.17 0.00 01-JAN-13:45 20324.31 22-DEC-05:00
Heating:EnergyTransfer:Zone:LIVING_UNIT1 37434.17 0.00 01-JAN-13:45 20324.31 22-DEC-05:00
Cooling:EnergyTransfer 6077.97 0.00 01-JAN-00:15 16281.64 02-APR-16:30
Cooling:EnergyTransfer:Zone:LIVING_UNIT1 6077.97 0.00 01-JAN-00:15 16281.64 02-APR-16:30
EnergyTransfer:Zone:ATTIC_UNIT1 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:ATTIC_UNIT1 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:ATTIC_UNIT1 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:CRAWLSPACE_UNIT1 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:CRAWLSPACE_UNIT1 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:CRAWLSPACE_UNIT1 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Plant 11108.96 110.54 07-AUG-03:00 2585.38 05-FEB-08:45
WaterSystems:EnergyTransfer 11108.96 110.54 07-AUG-03:00 2585.38 05-FEB-08:45
Domestic Hot Water:WaterSystems:EnergyTransfer 11108.96 110.54 07-AUG-03:00 2585.38 05-FEB-08:45
EnergyTransfer:HVAC 42664.04 0.00 01-JAN-13:45 19450.69 22-DEC-05:00
CoolingCoils:EnergyTransfer 6983.96 0.00 01-JAN-00:15 18082.89 02-JUN-16:00
HeatingCoils:EnergyTransfer 35680.08 0.00 01-JAN-13:45 19450.69 22-DEC-05:00



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2019-02-14 08:52:14

Annual Building Sensible Heat Gain Components

HVAC Zone Eq & Other Sensible Air Heating [kBtu] HVAC Zone Eq & Other Sensible Air Cooling [ton-hrs] HVAC Terminal Unit Sensible Air Heating [kBtu] HVAC Terminal Unit Sensible Air Cooling [ton-hrs] HVAC Input Heated Surface Heating [kBtu] HVAC Input Cooled Surface Cooling [ton-hrs] People Sensible Heat Addition [kBtu] Lights Sensible Heat Addition [kBtu] Equipment Sensible Heat Addition [kBtu] Window Heat Addition [kBtu] Interzone Air Transfer Heat Addition [kBtu] Infiltration Heat Addition [kBtu] Opaque Surface Conduction and Other Heat Addition [kBtu] Equipment Sensible Heat Removal [kBtu] Window Heat Removal [kBtu] Interzone Air Transfer Heat Removal [kBtu] Infiltration Heat Removal [kBtu] Opaque Surface Conduction and Other Heat Removal [kBtu]
LIVING_UNIT1 0.000 0.000 37433.845 -506.15 0.000 0.000 4698.039 4565.600 16883.373 12417.146 0.000 128.790 0.000 0.000 -14009.33 0.000 -34054.84 -21984.80
ATTIC_UNIT1 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 670.158 6338.028 0.000 0.000 0.000 -7008.19 -0.08
CRAWLSPACE_UNIT1 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 162.705 4016.326 0.000 0.000 0.000 -4179.03 0.000
Total Facility 0.000 0.000 37433.845 -506.15 0.000 0.000 4698.039 4565.600 16883.373 12417.146 0.000 961.653 10354.354 0.000 -14009.33 0.000 -45242.05 -21984.88


Peak Cooling Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [Btu/h] HVAC Zone Eq & Other Sensible Air Cooling [ton] HVAC Terminal Unit Sensible Air Heating [Btu/h] HVAC Terminal Unit Sensible Air Cooling [ton] HVAC Input Heated Surface Heating [Btu/h] HVAC Input Cooled Surface Cooling [ton] People Sensible Heat Addition [Btu/h] Lights Sensible Heat Addition [Btu/h] Equipment Sensible Heat Addition [Btu/h] Window Heat Addition [Btu/h] Interzone Air Transfer Heat Addition [Btu/h] Infiltration Heat Addition [Btu/h] Opaque Surface Conduction and Other Heat Addition [Btu/h] Equipment Sensible Heat Removal [Btu/h] Window Heat Removal [Btu/h] Interzone Air Transfer Heat Removal [Btu/h] Infiltration Heat Removal [Btu/h] Opaque Surface Conduction and Other Heat Removal [Btu/h]
LIVING_UNIT1 02-APR-16:30 0.00 0.00 0.00 -1.4 0.00 0.00 210.65 715.19 2164.12 7556.63 0.00 1471.77 4166.34 0.00 0.00 0.00 0.00 0.00
ATTIC_UNIT1 - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
CRAWLSPACE_UNIT1 - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 02-APR-16:30 0.00 0.00 0.00 -1.4 0.00 0.00 210.65 715.19 2164.12 7556.63 0.00 2132.29 5322.30 0.00 0.00 0.00 -1816.5 0.00


Peak Heating Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [Btu/h] HVAC Zone Eq & Other Sensible Air Cooling [ton] HVAC Terminal Unit Sensible Air Heating [Btu/h] HVAC Terminal Unit Sensible Air Cooling [ton] HVAC Input Heated Surface Heating [Btu/h] HVAC Input Cooled Surface Cooling [ton] People Sensible Heat Addition [Btu/h] Lights Sensible Heat Addition [Btu/h] Equipment Sensible Heat Addition [Btu/h] Window Heat Addition [Btu/h] Interzone Air Transfer Heat Addition [Btu/h] Infiltration Heat Addition [Btu/h] Opaque Surface Conduction and Other Heat Addition [Btu/h] Equipment Sensible Heat Removal [Btu/h] Window Heat Removal [Btu/h] Interzone Air Transfer Heat Removal [Btu/h] Infiltration Heat Removal [Btu/h] Opaque Surface Conduction and Other Heat Removal [Btu/h]
LIVING_UNIT1 22-DEC-05:00 0.00 0.00 20322.43 0.00 0.00 0.00 789.46 306.51 1376.37 0.00 0.00 0.00 0.00 0.00 -3788.3 0.00 -13993.2 -5013.2
ATTIC_UNIT1 - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
CRAWLSPACE_UNIT1 - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 22-DEC-05:00 0.00 0.00 20322.43 0.00 0.00 0.00 789.46 306.51 1376.37 0.00 0.00 282.13 0.00 0.00 -3788.3 0.00 -16128.7 -3159.9



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2019-02-14 08:52:14

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [ft3/min] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [ft3/min] System Primary Airflow - Vps [ft3/min] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [ft3/min] Percent Outdoor Air - %OA
CENTRAL SYSTEM_UNIT1 678.761 3.00 3.00 1.00 59.9933 678.761 0.088 1.000 59.9933 0.09


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [ft3/min] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [ft3/min] System Primary Airflow - Vps [ft3/min] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [ft3/min] Percent Outdoor Air - %OA
CENTRAL SYSTEM_UNIT1 327.742 3.00 3.00 1.00 59.9933 327.742 1.000 1.000 59.9933 0.18


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [ft3/min-person] Zone Population - Pz Area Outdoor Air Rate - Ra [ft3/min-ft2] Zone Floor Area - Az [ft2] Breathing Zone Outdoor Airflow - Vbz [ft3/min] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [ft3/min] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [ft3/min]
LIVING_UNIT1 CENTRAL SYSTEM_UNIT1 0.000000 3.00 0.000000 2377.10 59.9933 1.000 59.9933 1.000 59.9933


System Ventilation Parameters

People Outdoor Air Rate - Rp [ft3/min-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [ft3/min-ft2] Sum of Zone Floor Area - Az-sum [ft2] Breathing Zone Outdoor Airflow - Vbz [ft3/min] Cooling Zone Outdoor Airflow - Voz-clg [ft3/min] Heating Zone Outdoor Airflow - Voz-htg [ft3/min]
CENTRAL SYSTEM_UNIT1 0.000000 3.00 0.000000 2377.10 59.9933 59.9933 59.9933


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [ft3/min] Zone Discharge Airflow - Vdz [ft3/min] Minimum Zone Primary Airflow - Vpz-min [ft3/min] Zone Outdoor Airflow Cooling - Voz-clg [ft3/min] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
LIVING_UNIT1 CENTRAL SYSTEM_UNIT1   678.761 678.7610 356.4898 59.9933 0.000 1.000 0.000 0.000 0.000 0.000 1.000


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [ft3/min] System Primary Airflow - Vps [ft3/min] Sum of Zone Discharge Airflow - Vdz-sum [ft3/min] Sum of Min Zone Primary Airflow - Vpz-min [ft3/min] Zone Outdoor Airflow Cooling - Voz-clg [ft3/min] Zone Ventilation Efficiency - Evz-min
CENTRAL SYSTEM_UNIT1 678.76 678.761 678.76 356.4898 59.9933 1.000


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [ft3/min] Zone Discharge Airflow - Vdz [ft3/min] Minimum Zone Primary Airflow - Vpz-min [ft3/min] Zone Outdoor Airflow Heating - Voz-htg [ft3/min] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
LIVING_UNIT1 CENTRAL SYSTEM_UNIT1   327.742 327.742 327.742 59.9933 0.183 1.000 0.000 0.000 0.000 0.000 1.000


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [ft3/min] System Primary Airflow - Vps [ft3/min] Sum of Zone Discharge Airflow - Vdz-sum [ft3/min] Sum of Min Zone Primary Airflow - Vpz-min [ft3/min] Zone Outdoor Airflow Heating - Voz-htg [ft3/min] Zone Ventilation Efficiency - Evz-min
CENTRAL SYSTEM_UNIT1 327.74 327.742 327.74 327.74 59.9933 1.000



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2019-02-14 08:52:14

Sec1.1A-General Information

Data
Weather File ANNUAL ** San Francisco Intl Ap CA USA TMY3 WMO#=724940
Total gross floor area [ft2] 4754.19
Principal Heating Source Electricity


EAp2-1. Space Usage Type

Space Area [ft2] Regularly Occupied Area [ft2] Unconditioned Area [ft2] Typical Hours/Week in Operation [hr/wk]
LIVING_UNIT1 2377.10 2377.10 0.00 168.00
ATTIC_UNIT1 1188.55 0.00 1188.55 0.00
CRAWLSPACE_UNIT1 1188.55 0.00 1188.55 0.00
Totals 4754.19 2377.10 2377.10  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 0.00
Number of hours cooling loads not met 5.50
Number of hours not met 5.50


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [kWh] Electric Demand [W] Natural Gas Energy Use [therm] Natural Gas Demand [Btu/h] Additional Energy Use [kBtu] Additional Demand [Btu/h]
Interior Lighting 1337.15 209.61 0.00 0.00 0.00 0.00
Exterior Lighting 300.16 4.89 0.00 0.00 0.00 0.00
Space Heating 3160.91 3036.56 0.00 0.00 0.00 0.00
Space Cooling 453.79 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Fans-Interior 621.23 256.02 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 3517.52 2031.49 0.00 0.00 0.00 0.00
Receptacle Equipment 7792.16 775.76 0.00 0.00 0.00 0.00
Interior Lighting-Process 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 17182.92   0.00   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [kBtu] Total Energy Use [kBtu]
Electricity 26605.68 58669.66
Natural Gas 0.00 0.00
Additional 0.00 0.00
Total 26605.68 58669.66


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [kBtu]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [kWh/ft2]
Interior Lighting 0.28
Space Heating 0.66
Space Cooling 0.10
Fans-Interior 0.13
Service Water Heating 0.74
Receptacle Equipment 1.64
Miscellaneous 0.06
Subtotal 3.61


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [kWh/ft2]
Space Heating 0.00
Service Water Heating 0.00
Miscellaneous 0.00
Subtotal 0.00


EAp2-17c. Energy Use Intensity - Additional

Additional [kBtu/ft2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 7.78
Space Heating 18.40
Space Cooling 2.64
Fans-Interior 3.62
Service Water Heating 20.47
Receptacle Equipment 45.35
Miscellaneous 1.75



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2019-02-14 08:52:14

AirTerminal:SingleDuct:Uncontrolled

Design Size Maximum Air Flow Rate [ft3/min]
ZONEDIRECTAIR_UNIT1 678.76
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

AirLoopHVAC

Design Supply Air Flow Rate [ft3/min]
CENTRAL SYSTEM_UNIT1 678.76
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Cooling:DX:SingleSpeed

Design Size Rated Air Flow Rate [ft3/min] Design Size Gross Rated Total Cooling Capacity [ton] Design Size Gross Rated Sensible Heat Ratio
DX COOLING COIL_UNIT1 678.76 1.51 0.798655
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

AirLoopHVAC:UnitaryHeatPump:AirToAir

Supply Air Flow Rate [ft3/min] Supply Air Flow Rate During Heating Operation [ft3/min] Supply Air Flow Rate During Cooling Operation [ft3/min] Nominal Heating Capacity [Btu/h] Nominal Cooling Capacity [ton] Supplemental Heating Coil Nominal Capacity [Btu/h] Fraction of Supply Air Flow That Goes Through the Controlling Zone
HEAT PUMP_UNIT1 678.76 678.76 678.76 18095.02 1.51 19895.68 1.00
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Fan:OnOff

Design Size Maximum Flow Rate [ft3/min]
SUPPLY FAN_UNIT1 678.76
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Heating:DX:SingleSpeed

Design Size Rated Air Flow Rate [ft3/min] Design Size Gross Rated Heating Capacity [Btu/h]
MAIN DX HEATING COIL_UNIT1 678.76 18095.02
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Heating:Electric

Design Size Nominal Capacity [Btu/h]
SUPP HEATING COIL_UNIT1 19895.68
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

PlantLoop

Maximum Loop Flow Rate [ft3/min] Plant Loop Volume [ft3]
DHW LOOP_UNIT1 1.05 19.62
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Pump:VariableSpeed

Design Flow Rate [ft3/min]
MAINS PRESSURE_UNIT1 1.05
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

WaterHeater:Mixed

Maximum Heater Capacity [Btu/h] Use Side Design Flow Rate [ft3/min]
WATER HEATER_UNIT1 18766.00 1.05
User-Specified values were used. Design Size values were used if no User-Specified values were provided.


Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2019-02-14 08:52:14

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

Possible Shadow Receivers
OVERHANG_SDR_1.UNIT1 WALL_SDR_1.UNIT1 |
Mir-OVERHANG_SDR_1.UNIT1 OVERHANG_SDR_2.UNIT1 | WALL_SDR_1.UNIT1 | WALL_SDR_2.UNIT1 | ROOF_RIGHT_UNIT1 |
OVERHANG_SDR_2.UNIT1 WALL_SDR_2.UNIT1 |
Mir-OVERHANG_SDR_2.UNIT1 WALL_SDR_2.UNIT1 | ROOF_RIGHT_UNIT1 |
WALL_SDR_1.UNIT1 OVERHANG_SDR_1.UNIT1 | OVERHANG_SDR_2.UNIT1 |
WALL_SDR_2.UNIT1 OVERHANG_SDR_2.UNIT1 |
BGWALL_UPPER_SDR OVERHANG_SDR_1.UNIT1 | OVERHANG_SDR_2.UNIT1 |


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
WALL_LDF_1.UNIT1 WINDOW_LDF_1.UNIT1 |
WALL_SDR_1.UNIT1 WINDOW_SDR_1.UNIT1 |
WALL_LDB_1.UNIT1 WINDOW_LDB_1.UNIT1 | DOOR_LDB_UNIT1 |
WALL_SDL_1.UNIT1 WINDOW_SDL_1.UNIT1 |
WALL_LDF_2.UNIT1 WINDOW_LDF_2.UNIT1 |
WALL_SDR_2.UNIT1 WINDOW_SDR_2.UNIT1 |
WALL_LDB_2.UNIT1 WINDOW_LDB_2.UNIT1 |
WALL_SDL_2.UNIT1 WINDOW_SDL_2.UNIT1 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2019-02-14 08:52:14

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: FANSPLIT

For: CENTRAL SYSTEM_UNIT1

Timestamp: 2019-02-14 08:52:14

Custom Monthly Report

AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] AIR SYSTEM FAN ELECTRIC ENERGY {FOR HOURS SHOWN} [kWh] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY {HOURS NON-ZERO} [HOURS] AIR SYSTEM FAN ELECTRIC ENERGY {FOR HOURS SHOWN} [kWh] AIR SYSTEM FAN ELECTRIC ENERGY [kWh]
January 0.667 0.005 710.448 87.278 87.283
February 44.871 2.804 550.875 57.416 60.220
March 84.204 6.441 535.375 51.986 58.428
April 97.443 7.102 497.112 40.835 47.937
May 126.981 9.251 439.521 32.487 41.738
June 169.948 15.270 405.883 31.237 46.507
July 186.183 12.546 379.017 22.457 35.003
August 214.494 19.459 363.850 20.186 39.644
September 219.308 20.009 353.125 19.003 39.011
October 140.185 11.090 460.746 31.492 42.582
November 48.937 3.114 557.767 46.560 49.674
December 12.250 0.436 674.250 72.763 73.200
           
Annual Sum or Average 1345.471 107.526 5927.969 513.700 621.226
Minimum of Months 0.667 0.005 353.125 19.003 35.003
Maximum of Months 219.308 20.009 710.448 87.278 87.283



Table of Contents

Report: COILLOADS

For: MAIN DX HEATING COIL_UNIT1

Timestamp: 2019-02-14 08:52:14

Custom Monthly Report

HEATING COIL TOTAL HEATING RATE [Btu/h] HEATING COIL AIR HEATING RATE [Invalid/Undefined] COOLING COIL TOTAL COOLING RATE [Invalid/Undefined]
January 7588.14 0.00 0.00
February 5777.60 0.00 0.00
March 4813.58 0.00 0.00
April 4013.58 0.00 0.00
May 3111.39 0.00 0.00
June 3102.14 0.00 0.00
July 2216.16 0.00 0.00
August 2001.91 0.00 0.00
September 1959.90 0.00 0.00
October 3053.47 0.00 0.00
November 4498.88 0.00 0.00
December 6536.61 0.00 0.00
       
Annual Sum or Average 4049.22 0.00 0.00
Minimum of Months 1959.90 0.00 0.00
Maximum of Months 7588.14 0.00 0.00



Table of Contents

Report: COILLOADS

For: SUPP HEATING COIL_UNIT1

Timestamp: 2019-02-14 08:52:14

Custom Monthly Report

HEATING COIL TOTAL HEATING RATE [Invalid/Undefined] HEATING COIL AIR HEATING RATE [Btu/h] COOLING COIL TOTAL COOLING RATE [Invalid/Undefined]
January 0.00 132.38 0.00
February 0.00 0.23 0.00
March 0.00 9.49 0.00
April 0.00 0.00 0.00
May 0.00 0.00 0.00
June 0.00 0.00 0.00
July 0.00 0.00 0.00
August 0.00 0.00 0.00
September 0.00 0.00 0.00
October 0.00 0.00 0.00
November 0.00 26.22 0.00
December 0.00 79.30 0.00
       
Annual Sum or Average 0.00 20.96 0.00
Minimum of Months 0.00 0.00 0.00
Maximum of Months 0.00 132.38 0.00



Table of Contents

Report: COILLOADS

For: DX COOLING COIL_UNIT1

Timestamp: 2019-02-14 08:52:14

Custom Monthly Report

HEATING COIL TOTAL HEATING RATE [Invalid/Undefined] HEATING COIL AIR HEATING RATE [Invalid/Undefined] COOLING COIL TOTAL COOLING RATE [ton]
January 0.00 0.00 0.00
February 0.00 0.00 0.02
March 0.00 0.00 0.05
April 0.00 0.00 0.05
May 0.00 0.00 0.07
June 0.00 0.00 0.12
July 0.00 0.00 0.09
August 0.00 0.00 0.14
September 0.00 0.00 0.15
October 0.00 0.00 0.08
November 0.00 0.00 0.02
December 0.00 0.00 0.00
       
Annual Sum or Average 0.00 0.00 0.07
Minimum of Months 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.15



Table of Contents

Report: WATER HEATER: LOADS

For: WATER HEATER_UNIT1

Timestamp: 2019-02-14 08:52:14

Custom Monthly Report

WATER HEATER TOTAL DEMAND RATE [Invalid/Undefined] WATER HEATER TOTAL DEMAND ENERGY [Invalid/Undefined] WATER HEATER HEATING RATE [Btu/h] WATER HEATER HEATING ENERGY [kBtu]
January 0.00 0.00 1458.43 1085.84
February 0.00 0.00 1461.90 983.09
March 0.00 0.00 1445.50 1076.22
April 0.00 0.00 1409.36 1015.46
May 0.00 0.00 1358.66 1011.56
June 0.00 0.00 1312.21 945.46
July 0.00 0.00 1285.16 956.84
August 0.00 0.00 1273.52 948.17
September 0.00 0.00 1296.30 934.00
October 0.00 0.00 1333.31 992.69
November 0.00 0.00 1382.42 996.05
December 0.00 0.00 1430.31 1064.91
         
Annual Sum or Average 0.00 0.00 1370.07 12010.29
Minimum of Months 0.00 0.00 1273.52 934.00
Maximum of Months 0.00 0.00 1461.90 1085.84