Table of Contents

Program Version:EnergyPlus, Version 8.6.0-Unknown, YMD=2019.02.14 08:57

Tabular Output Report in Format: HTML

Building: SF+CZ3CWH+USA_CA_San.Francisco.Intl.AP.724940+oilfurnace+heatedbsmt+IECC_2012

Environment: ANNUAL ** San Francisco Intl Ap CA USA TMY3 WMO#=724940

Simulation Timestamp: 2019-02-14 08:57:21


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2019-02-14 08:57:21

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [kBtu] Energy Per Total Building Area [kBtu/ft2] Energy Per Conditioned Building Area [kBtu/ft2]
Total Site Energy 73480.15 15.46 20.61
Net Site Energy 73480.15 15.46 20.61
Total Source Energy 161348.82 33.94 45.25
Net Source Energy 161348.82 33.94 45.25


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [ft2]
Total Building Area 4754.19
Net Conditioned Building Area 3565.64
Unconditioned Building Area 1188.55


End Uses

Electricity [kBtu] Natural Gas [kBtu] Additional Fuel [kBtu] District Cooling [kBtu] District Heating [kBtu] Water [gal]
Heating 0.00 0.00 15542.63 0.00 0.00 0.00
Cooling 1797.41 0.00 0.00 0.00 0.00 0.00
Interior Lighting 6069.37 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 870.96 0.00 0.00 0.00 0.00 0.00
Interior Equipment 29942.93 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 1090.07 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 0.00 18166.78 0.00 0.00 26547.80
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 39770.74 0.00 33709.40 0.00 0.00 26547.80
Note: Additional fuel appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [kBtu] Natural Gas [kBtu] Additional Fuel [kBtu] District Cooling [kBtu] District Heating [kBtu] Water [gal]
Heating General 0.00 0.00 15542.63 0.00 0.00 0.00
Cooling General 1797.41 0.00 0.00 0.00 0.00 0.00
Interior Lighting General 6069.37 0.00 0.00 0.00 0.00 0.00
Exterior Lighting Exterior-Lights 780.36 0.00 0.00 0.00 0.00 0.00
  Garage-Lights 90.60 0.00 0.00 0.00 0.00 0.00
Interior Equipment dishwasher 632.73 0.00 0.00 0.00 0.00 0.00
  refrigerator 2283.13 0.00 0.00 0.00 0.00 0.00
  clotheswasher 323.13 0.00 0.00 0.00 0.00 0.00
  electric_dryer 2845.15 0.00 0.00 0.00 0.00 0.00
  electric_range 2062.62 0.00 0.00 0.00 0.00 0.00
  television 0.00 0.00 0.00 0.00 0.00 0.00
  electric_mels 11465.79 0.00 0.00 0.00 0.00 0.00
  IECC_adj 10330.38 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 1090.07 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 0.00 18166.78 0.00 0.00 0.00
  Domestic Hot Water 0.00 0.00 0.00 0.00 0.00 26547.80
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [kBtu/ft2] Natural Gas Intensity [kBtu/ft2] Additional Fuel Intensity [kBtu/ft2] District Cooling Intensity [kBtu/ft2] District Heating Intensity [kBtu/ft2] Water Intensity [gal/ft2]
Lighting 1.95 0.00 0.00 0.00 0.00 0.00
HVAC 0.81 0.00 9.45 0.00 0.00 7.45
Other 8.40 0.00 0.00 0.00 0.00 0.00
Total 11.15 0.00 9.45 0.00 0.00 7.45


Utility Use Per Total Floor Area

Electricity Intensity [kBtu/ft2] Natural Gas Intensity [kBtu/ft2] Additional Fuel Intensity [kBtu/ft2] District Cooling Intensity [kBtu/ft2] District Heating Intensity [kBtu/ft2] Water Intensity [gal/ft2]
Lighting 1.46 0.00 0.00 0.00 0.00 0.00
HVAC 0.61 0.00 7.09 0.00 0.00 5.58
Other 6.30 0.00 0.00 0.00 0.00 0.00
Total 8.37 0.00 7.09 0.00 0.00 5.58


Electric Loads Satisfied

Electricity [kBtu] Percent Electricity [%]
Fuel-Fired Power Generation 0.000 0.00
High Temperature Geothermal* 0.000 0.00
Photovoltaic Power 0.000 0.00
Wind Power 0.000 0.00
Power Conversion 0.000 0.00
Net Decrease in On-Site Storage 0.000 0.00
Total On-Site Electric Sources 0.000 0.00
     
Electricity Coming From Utility 39770.744 100.00
Surplus Electricity Going To Utility 0.000 0.00
Net Electricity From Utility 39770.744 100.00
     
Total On-Site and Utility Electric Sources 39770.744 100.00
Total Electricity End Uses 39770.744 100.00


On-Site Thermal Sources

Heat [kBtu] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [gal] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 26547.80 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 26547.80 100.00
Total Water End Uses 26547.80 100.00


Setpoint Not Met Criteria

Degrees [deltaF]
Tolerance for Zone Heating Setpoint Not Met Time 0.36
Tolerance for Zone Cooling Setpoint Not Met Time 0.36


Comfort and Setpoint Not Met Summary

Facility [Hours]
Time Setpoint Not Met During Occupied Heating 0.00
Time Setpoint Not Met During Occupied Cooling 0.00
Time Not Comfortable Based on Simple ASHRAE 55-2004 1.50


Note 1: An asterisk (*) indicates that the feature is not yet implemented.

Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Adaptive Comfort Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

FANSPLIT

| CENTRAL SYSTEM_UNIT1 |

COILLOADS

| MAIN FUEL HEATING COIL_UNIT1 | DX COOLING COIL_UNIT1 |

WATER HEATER: LOADS

| WATER HEATER_UNIT1 |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2019-02-14 08:57:21

General

Value
Program Version and Build EnergyPlus, Version 8.6.0-Unknown, YMD=2019.02.14 08:57
RunPeriod ANNUAL
Weather File San Francisco Intl Ap CA USA TMY3 WMO#=724940
Latitude [deg] 37.62
Longitude [deg] -122.4
Elevation [ft] 6.56
Time Zone -8.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [ft2] 2627.41 716.77 596.93 716.77 596.93
Above Ground Wall Area [ft2] 2627.41 716.77 596.93 716.77 596.93
Window Opening Area [ft2] 287.71 71.93 71.93 71.93 71.93
Gross Window-Wall Ratio [%] 10.95 10.03 12.05 10.03 12.05
Above Ground Window-Wall Ratio [%] 10.95 10.03 12.05 10.03 12.05


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [ft2] 2508.71 716.77 537.58 716.77 537.58
Above Ground Wall Area [ft2] 2508.71 716.77 537.58 716.77 537.58
Window Opening Area [ft2] 287.71 71.93 71.93 71.93 71.93
Gross Window-Wall Ratio [%] 11.47 10.03 13.38 10.03 13.38
Above Ground Window-Wall Ratio [%] 11.47 10.03 13.38 10.03 13.38


Skylight-Roof Ratio

Total
Gross Roof Area [ft2] 1229.98
Skylight Area [ft2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [ft2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [ft3] Multipliers Above Ground Gross Wall Area [ft2] Underground Gross Wall Area [ft2] Window Glass Area [ft2] Opening Area [ft2] Lighting [Btu/h-ft2] People [ft2 per person] Plug and Process [Btu/h-ft2]
LIVING_UNIT1 3565.64 Yes Yes 25957.87 1.00 2508.71 0.00 287.71 287.71 0.5541 1188.55 1.6509
ATTIC_UNIT1 1188.55 No Yes 2362.70 1.00 118.70 0.00 0.00 0.00 0.0000   0.0000
Total 4754.19     28320.57   2627.41 0.00 287.71 287.71 0.4155 1584.73 1.2381
Conditioned Total 3565.64     25957.87   2508.71 0.00 287.71 287.71 0.5541 1188.55 1.6509
Unconditioned Total 1188.55     2362.70   118.70 0.00 0.00 0.00 0.0000   0.0000
Not Part of Total 0.00     0.00   0.00 0.00 0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2019-02-14 08:57:21

End Uses

Electricity [kBtuh] Natural Gas [kBtuh] Fuel Oil #2 [kBtuh] District Cooling [kBtuh] Steam [kBtuh] Water [gal/min]
Time of Peak 30-JUN-18:15 - 24-JAN-05:00 - - 08-JAN-08:45
Heating 0.00 0.00 13.08 0.00 0.00 0.00
Cooling 3.18 0.00 0.00 0.00 0.00 0.00
Interior Lighting 1.78 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.20 0.00 0.00 0.00 0.00 0.00
Interior Equipment 4.99 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 0.72 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 0.00 0.00 0.00 0.00 0.10
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 10.88 0.00 13.08 0.00 0.00 0.10
Additional fuels have non-zero demand but are not shown on this report.

End Uses By Subcategory

Subcategory Electricity [kBtuh] Natural Gas [kBtuh] Fuel Oil #2 [kBtuh] District Cooling [kBtuh] Steam [kBtuh] Water [gal/min]
Heating General 0.00 0.00 13.08 0.00 0.00 0.00
Cooling General 3.18 0.00 0.00 0.00 0.00 0.00
Interior Lighting General 1.78 0.00 0.00 0.00 0.00 0.00
Exterior Lighting Exterior-Lights 0.18 0.00 0.00 0.00 0.00 0.00
  Garage-Lights 0.03 0.00 0.00 0.00 0.00 0.00
Interior Equipment dishwasher 0.15 0.00 0.00 0.00 0.00 0.00
  refrigerator 0.31 0.00 0.00 0.00 0.00 0.00
  clotheswasher 0.04 0.00 0.00 0.00 0.00 0.00
  electric_dryer 0.38 0.00 0.00 0.00 0.00 0.00
  electric_range 0.66 0.00 0.00 0.00 0.00 0.00
  television 0.00 0.00 0.00 0.00 0.00 0.00
  electric_mels 1.81 0.00 0.00 0.00 0.00 0.00
  IECC_adj 1.64 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 0.72 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 0.00 0.00 0.00 0.00 0.00
  Domestic Hot Water 0.00 0.00 0.00 0.00 0.00 0.10
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00
Additional fuels have non-zero demand but are not shown on this report.


Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2019-02-14 08:57:21

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [kBtu] Source Natural Gas [kBtu] Source Additional Fuel [kBtu] Source District Cooling [kBtu] Source District Heating [kBtu]
Heating 0.00 0.00 16319.76 0.00 0.00
Cooling 5692.40 0.00 0.00 0.00 0.00
Interior Lighting 19221.68 0.00 0.00 0.00 0.00
Exterior Lighting 2758.33 0.00 0.00 0.00 0.00
Interior Equipment 94829.27 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 3452.26 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 0.00 19075.11 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 125953.95 0.00 35394.87 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [kBtu/ft2] Source Natural Gas [kBtu/ft2] Source Additional Fuel [kBtu/ft2] Source District Cooling [kBtu/ft2] Source District Heating [kBtu/ft2]
Heating 0.00 0.00 4.58 0.00 0.00
Cooling 1.60 0.00 0.00 0.00 0.00
Interior Lighting 5.39 0.00 0.00 0.00 0.00
Exterior Lighting 0.77 0.00 0.00 0.00 0.00
Interior Equipment 26.60 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 0.97 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 0.00 5.35 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 35.32 0.00 9.93 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [kBtu/ft2] Source Natural Gas [kBtu/ft2] Source Additional Fuel [kBtu/ft2] Source District Cooling [kBtu/ft2] Source District Heating [kBtu/ft2]
Heating 0.00 0.00 4.58 0.00 0.00
Cooling 1.60 0.00 0.00 0.00 0.00
Interior Lighting 5.39 0.00 0.00 0.00 0.00
Exterior Lighting 0.77 0.00 0.00 0.00 0.00
Interior Equipment 26.60 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 0.97 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 0.00 5.35 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 35.32 0.00 9.93 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2019-02-14 08:57:21

SizingPeriod:DesignDay

Maximum Dry Bulb [F] Daily Temperature Range [deltaF] Humidity Value Humidity Type Wind Speed [ft/min] Wind Direction
SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 38.84 0.00 38.84 Wetbulb [F] 433.09 150.00
SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 82.94 15.30 62.96 Wetbulb [F] 1161.47 310.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2019-02-14 08:57:21

Opaque Exterior

Construction Reflectance U-Factor with Film [Btu/h-ft2-F] U-Factor no Film [Btu/h-ft2-F] Gross Area [ft2] Net Area [ft2] Azimuth [deg] Tilt [deg] Cardinal Direction
WALL_LDF_1.UNIT1 EXTERIOR WALL 0.30 0.060 0.063 338.48 302.51 180.00 90.00 S
WALL_SDR_1.UNIT1 EXTERIOR WALL 0.30 0.060 0.063 253.86 217.89 90.00 90.00 E
WALL_LDB_1.UNIT1 EXTERIOR WALL 0.30 0.060 0.063 338.48 262.50 0.00 90.00 N
WALL_SDL_1.UNIT1 EXTERIOR WALL 0.30 0.060 0.063 253.86 217.89 270.00 90.00 W
WALL_LDF_2.UNIT1 EXTERIOR WALL 0.30 0.060 0.063 338.48 302.51 180.00 90.00 S
WALL_SDR_2.UNIT1 EXTERIOR WALL 0.30 0.060 0.063 253.86 217.89 90.00 90.00 E
WALL_LDB_2.UNIT1 EXTERIOR WALL 0.30 0.060 0.063 338.48 302.51 0.00 90.00 N
WALL_SDL_2.UNIT1 EXTERIOR WALL 0.30 0.060 0.063 253.86 217.89 270.00 90.00 W
BGWALL_UPPER_LDF BASEMENT WALL 0.30 0.087 0.094 39.82 39.82 180.00 90.00 S
BGWALL_UPPER_SDR BASEMENT WALL 0.30 0.087 0.094 29.87 29.87 90.00 90.00 E
BGWALL_UPPER_LDB BASEMENT WALL 0.30 0.087 0.094 39.82 39.82 0.00 90.00 N
BGWALL_UPPER_SDL BASEMENT WALL 0.30 0.087 0.094 29.87 29.87 270.00 90.00 W
ROOF_RIGHT_UNIT1 GABLE_END 0.30 0.314 0.428 59.35 59.35 90.00 90.00 E
ROOF_LEFT_UNIT1 GABLE_END 0.30 0.314 0.428 59.35 59.35 270.00 90.00 W
ROOF_FRONT_UNIT1 EXTERIOR ROOF 0.25 0.543 0.943 614.99 614.99 180.00 14.91  
ROOF_BACK_UNIT1 EXTERIOR ROOF 0.25 0.543 0.943 614.99 614.99 0.00 14.91  


Exterior Fenestration

Construction Glass Area [ft2] Frame Area [ft2] Divider Area [ft2] Area of One Opening [ft2] Area of Multiplied Openings [ft2] Glass U-Factor [Btu/h-ft2-F] Glass SHGC Glass Visible Transmittance Frame Conductance [Btu/h-ft2-F] Divider Conductance [Btu/h-ft2-F] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
WINDOW_LDF_1.UNIT1 EXTERIOR WINDOW 35.96 0.00 0.00 35.96 35.96 0.350 0.218 0.882     Yes WALL_LDF_1.UNIT1 180.00 90.00 S
WINDOW_SDR_1.UNIT1 EXTERIOR WINDOW 35.96 0.00 0.00 35.96 35.96 0.350 0.218 0.882     Yes WALL_SDR_1.UNIT1 90.00 90.00 E
WINDOW_LDB_1.UNIT1 EXTERIOR WINDOW 35.96 0.00 0.00 35.96 35.96 0.350 0.218 0.882     Yes WALL_LDB_1.UNIT1 0.00 90.00 N
WINDOW_SDL_1.UNIT1 EXTERIOR WINDOW 35.96 0.00 0.00 35.96 35.96 0.350 0.218 0.882     Yes WALL_SDL_1.UNIT1 270.00 90.00 W
WINDOW_LDF_2.UNIT1 EXTERIOR WINDOW 35.96 0.00 0.00 35.96 35.96 0.350 0.218 0.882     Yes WALL_LDF_2.UNIT1 180.00 90.00 S
WINDOW_SDR_2.UNIT1 EXTERIOR WINDOW 35.96 0.00 0.00 35.96 35.96 0.350 0.218 0.882     Yes WALL_SDR_2.UNIT1 90.00 90.00 E
WINDOW_LDB_2.UNIT1 EXTERIOR WINDOW 35.96 0.00 0.00 35.96 35.96 0.350 0.218 0.882     Yes WALL_LDB_2.UNIT1 0.00 90.00 N
WINDOW_SDL_2.UNIT1 EXTERIOR WINDOW 35.96 0.00 0.00 35.96 35.96 0.350 0.218 0.882     Yes WALL_SDL_2.UNIT1 270.00 90.00 W
Total or Average           287.71 0.350 0.218 0.882              
North Total or Average           71.93 0.350 0.218 0.882              
Non-North Total or Average           215.78 0.350 0.218 0.882              


Interior Fenestration

Construction Area of One Opening [ft2] Area of Openings [ft2] Glass U-Factor [Btu/h-ft2-F] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [Btu/h-ft2-F] U-Factor no Film [Btu/h-ft2-F] Gross Area [ft2] Parent Surface
DOOR_LDB_UNIT1 EXTERIOR DOOR 0.270 0.350 40.02 WALL_LDB_1.UNIT1



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2019-02-14 08:57:21

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
WINDOW_LDF_1.UNIT1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
WINDOW_SDR_1.UNIT1 0.99 0.92 0.00 0.99 0.78 0.00 1.00 0.80 0.00
WINDOW_LDB_1.UNIT1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
WINDOW_SDL_1.UNIT1 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
WINDOW_LDF_2.UNIT1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
WINDOW_SDR_2.UNIT1 0.99 0.92 0.00 0.99 0.78 0.00 1.00 0.80 0.00
WINDOW_LDB_2.UNIT1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
WINDOW_SDL_2.UNIT1 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00


Window Control

Name Type Shaded Construction Control Glare Control
WINDOW_LDF_1.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No
WINDOW_SDR_1.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No
WINDOW_LDB_1.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No
WINDOW_SDL_1.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No
WINDOW_LDF_2.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No
WINDOW_SDR_2.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No
WINDOW_LDB_2.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No
WINDOW_SDL_2.UNIT1 SHADES Interior Blind WINDOW_W_BLINDS OnIfScheduleAllows No



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2019-02-14 08:57:21

Interior Lighting

Zone Lighting Power Density [Btu/h-ft2] Zone Area [ft2] Total Power [Btu/h] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [kWh]
LIVING HARDWIRED LIGHTING1 LIVING_UNIT1 0.4024 3565.64 1434.86 General INTERIORLIGHTINGHE 58.88 168.00 58.88 0.0000 Y 1291.03
LIVING PLUG-IN LIGHTING1 LIVING_UNIT1 0.1517 3565.64 540.74 General INTERIORLIGHTINGHE 58.88 168.00 58.88 0.0000 Y 486.54
Interior Lighting Total   0.2770 7131.29 1975.60               1777.57


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [Btu/h] Lighting Controlled [Btu/h]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [kWh]
EXTERIOR-LIGHTS_UNIT1 52.18 Schedule EXTERIORLIGHTING 84.00 84.00 84.00 228.55
GARAGE-LIGHTS_UNIT1 8.64 Schedule INTERIORLIGHTINGHE 58.88 168.00 58.88 26.54
Exterior Lighting Total 60.82           255.08



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2019-02-14 08:57:21

Central Plant

Type Nominal Capacity [Btu/h] Nominal Efficiency [Btuh/Btuh] IPLV in SI Units [Btuh/Btuh] IPLV in IP Units [Btu/W-h]
None          


Cooling Coils

Type Design Coil Load [Btu/h] Nominal Total Capacity [Btu/h] Nominal Sensible Capacity [Btu/h] Nominal Latent Capacity [Btu/h] Nominal Sensible Heat Ratio Nominal Efficiency [Btuh/Btuh] Nominal Coil UA Value [Btu/h-F] Nominal Coil Surface Area [ft2]
DX COOLING COIL_UNIT1 Coil:Cooling:DX:SingleSpeed   14975.12 11959.96 3015.16 0.80 4.07    
Nominal values are gross at rated conditions, i.e., the supply air fan heat and electric power NOT accounted for.

DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [ton] Standard Rated Net COP [Btuh/Btuh] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
DX COOLING COIL_UNIT1   1.2 3.26 11.12 11.77 11.27
ANSI/AHRI ratings account for supply air fan heat and electric power.

DX Cooling Coil ASHRAE 127 Standard Ratings Report

DX Cooling Coil Type Rated Net Cooling Capacity Test A [ton] Rated Electric Power Test A [W] Rated Net Cooling Capacity Test B [ton] Rated Electric Power Test B [W] Rated Net Cooling Capacity Test C [ton] Rated Electric Power Test C [W] Rated Net Cooling Capacity Test D [ton] Rated Electric Power Test D [W]
DX COOLING COIL_UNIT1 Coil:Cooling:DX:SingleSpeed                


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [Btu/h] Low Temperature Heating (net) Rating Capacity [Btu/h] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [Btu/h] Nominal Total Capacity [Btu/h] Nominal Efficiency [Btuh/Btuh]
MAIN FUEL HEATING COIL_UNIT1 Coil:Heating:Fuel   13365.24 0.78


Fans

Type Total Efficiency [Btuh/Btuh] Delta Pressure [psi] Max Air Flow Rate [ft3/min] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-min/ft3] Motor Heat In Air Fraction End Use
SUPPLY FAN_UNIT1 Fan:OnOff 0.50 0.06 561.73 211.88 0.38 1.00 General


Pumps

Type Control Head [psi] Water Flow [gal/min] Electric Power [W] Power Per Water Flow Rate [W-min/gal] Motor Efficiency [Btuh/Btuh]
MAINS PRESSURE_UNIT1 Pump:VariableSpeed Intermittent 0.00 7.827838 0.00 0.00 1.00


Service Water Heating

Type Storage Volume [ft3] Input [Btu/h] Thermal Efficiency [Btuh/Btuh] Recovery Efficiency [Btuh/Btuh] Energy Factor
WATER HEATER_UNIT1 WaterHeater:Mixed 6.95 38002.17 0.80 0.97 0.55



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2019-02-14 08:57:21

Zone Sensible Cooling

Calculated Design Load [Btu/h] User Design Load [Btu/h] User Design Load per Area [Btu/h-ft2] Calculated Design Air Flow [ft3/min] User Design Air Flow [ft3/min] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [F] Indoor Temperature at Peak Load [F] Indoor Humidity Ratio at Peak Load [lbWater/lbAir] Outdoor Temperature at Peak Load [F] Outdoor Humidity Ratio at Peak Load [lbWater/lbAir] Minimum Outdoor Air Flow Rate [ft3/min] Heat Gain Rate from DOAS [Btu/h]
LIVING_UNIT1 13194.87 13194.87 3.70 561.731 561.731 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 17:45:00 74.98 74.98 0.00813 79.65 0.00771 59.993 0.00
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

Zone Sensible Heating

Calculated Design Load [Btu/h] User Design Load [Btu/h] User Design Load per Area [Btu/h-ft2] Calculated Design Air Flow [ft3/min] User Design Air Flow [ft3/min] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [F] Indoor Temperature at Peak Load [F] Indoor Humidity Ratio at Peak Load [lbWater/lbAir] Outdoor Temperature at Peak Load [F] Outdoor Humidity Ratio at Peak Load [lbWater/lbAir] Minimum Outdoor Air Flow Rate [ft3/min] Heat Gain Rate from DOAS [Btu/h]
LIVING_UNIT1 11378.00 11378.00 3.19 207.129 207.129 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 14:00:00 72.00 71.99 0.00706 38.84 0.00496 59.993 0.00
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

System Design Air Flow Rates

Calculated cooling [ft3/min] User cooling [ft3/min] Calculated heating [ft3/min] User heating [ft3/min]
CENTRAL SYSTEM_UNIT1 561.73 561.73 207.13 207.13


Plant Loop Coincident Design Fluid Flow Rate Adjustments

Previous Design Volume Flow Rate [ft3/min] Algorithm Volume Flow Rate [ft3/min] Coincident Design Volume Flow Rate [ft3/min] Coincident Size Adjusted Peak Sizing Period Name Peak Day into Period {TIMESTAMP}[day] Peak Hour Of Day {TIMESTAMP}[hr] Peak Step Start Minute {TIMESTAMP}[min]
None                



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2019-02-14 08:57:21

Economizer

High Limit Shutoff Control Minimum Outdoor Air [ft3/min] Maximum Outdoor Air [ft3/min] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [F] Outdoor Air Enthalpy Limit [F]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [ft3/min-person] Outdoor Air Per Area [ft3/min-ft2] Outdoor Air Per Zone [ft3/min] Outdoor Air ACH [ACH] Outdoor Air Method Outdoor Air Schedule Name Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule Name
None                    


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
LIVING_UNIT1 308.25 6847.50 1.50
ATTIC_UNIT1 0.00 0.00 0.00
Facility 308.25 6847.50 1.50
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
LIVING_UNIT1 0.00 0.00 0.00 0.00
ATTIC_UNIT1 0.00 0.00 0.00 0.00
Facility 0.00 0.00 0.00 0.00
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2019-02-14 08:57:21

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [ft3] Mechanical Ventilation [ACH] Infiltration [ACH] AFN Infiltration [ACH] Simple Ventilation [ACH]
LIVING_UNIT1 2.07 3.00 25957.87 0.000 0.167 0.000 0.143
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [ft3] Mechanical Ventilation [ACH] Infiltration [ACH] AFN Infiltration [ACH] Simple Ventilation [ACH]
LIVING_UNIT1 2.07 3.00 25957.87 0.000 0.000 0.000 0.002
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2019-02-14 08:57:21

Surfaces by Class

Total Outdoors
Wall 18 14
Floor 4 0
Roof 4 2
Internal Mass 1 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 8 8
Door 1 1
Glass Door 0 0
Shading 4 4
Overhang 2 2
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 1
Conditioned Zones 1
Unconditioned Zones 1
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 376
Defaulted Fields 46
Fields with Defaults 1253
Autosized Fields 16
Autosizable Fields 22
Autocalculated Fields 20
Autocalculatable Fields 50



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2019-02-14 08:57:21

Annual and Peak Values - Electricity

Electricity Annual Value [kWh] Electricity Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Electricity Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
Electricity:Facility 11647.89 760.91 03-APR-03:15 3185.40 30-JUN-18:15
Electricity:Building 10547.13 708.13 02-JAN-03:15 2016.50 01-JAN-19:15
Electricity:Zone:LIVING_UNIT1 10547.13 708.13 02-JAN-03:15 2016.50 01-JAN-19:15
InteriorLights:Electricity 1777.57 39.81 01-JAN-00:15 579.01 01-JAN-19:15
InteriorLights:Electricity:Zone:LIVING_UNIT1 1777.57 39.81 01-JAN-00:15 579.01 01-JAN-19:15
General:InteriorLights:Electricity 1777.57 39.81 01-JAN-00:15 579.01 01-JAN-19:15
InteriorEquipment:Electricity 8769.56 656.09 02-JAN-04:15 1490.55 01-JAN-18:15
InteriorEquipment:Electricity:Zone:LIVING_UNIT1 8769.56 656.09 02-JAN-04:15 1490.55 01-JAN-18:15
dishwasher:InteriorEquipment:Electricity 185.31 1.70 02-JAN-03:15 59.13 01-JAN-19:15
refrigerator:InteriorEquipment:Electricity 668.67 66.60 01-JAN-04:15 91.06 01-JAN-18:15
clotheswasher:InteriorEquipment:Electricity 94.64 0.91 02-JAN-02:15 25.63 01-JAN-09:15
electric_dryer:InteriorEquipment:Electricity 833.27 4.25 02-JAN-03:15 213.06 01-JAN-11:15
electric_range:InteriorEquipment:Electricity 604.09 5.84 01-JAN-02:15 248.15 01-JAN-17:15
television:InteriorEquipment:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
electric_mels:InteriorEquipment:Electricity 3358.05 293.39 01-JAN-09:15 567.46 01-JAN-20:15
IECC_adj:InteriorEquipment:Electricity 3025.52 264.34 01-JAN-09:15 511.27 01-JAN-20:15
Fans:Electricity 319.26 0.00 01-JAN-13:45 211.88 02-JUN-15:00
Fans:Electricity:Zone:LIVING_UNIT1 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 11647.89 760.91 03-APR-03:15 3185.40 30-JUN-18:15
ElectricityPurchased:Plant 11647.89 760.91 03-APR-03:15 3185.40 30-JUN-18:15
Cogeneration:ElectricityPurchased 11647.89 760.91 03-APR-03:15 3185.40 30-JUN-18:15
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 11647.89 760.91 03-APR-03:15 3185.40 30-JUN-18:15
ElectricityNet:Plant 11647.89 760.91 03-APR-03:15 3185.40 30-JUN-18:15
Cogeneration:ElectricityNet 11647.89 760.91 03-APR-03:15 3185.40 30-JUN-18:15
ExteriorLights:Electricity 255.08 1.11 01-JAN-09:15 60.82 01-JAN-19:15
Exterior-Lights:ExteriorLights:Electricity 228.55 0.00 01-JAN-06:15 52.18 01-JAN-00:15
Garage-Lights:ExteriorLights:Electricity 26.54 0.59 01-JAN-00:15 8.64 01-JAN-19:15
Electricity:HVAC 845.67 0.00 01-JAN-13:45 1221.93 02-JUN-15:00
General:Fans:Electricity 319.26 0.00 01-JAN-13:45 211.88 02-JUN-15:00
Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:Electricity 526.42 0.00 01-JAN-00:15 1010.05 02-JUN-15:00
Electricity:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Pumps:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15


Annual and Peak Values - Gas

Gas Annual Value [therm] Gas Minimum Value [Btu/h] Timestamp of Minimum {TIMESTAMP} Gas Maximum Value [Btu/h] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Cooling

Cooling Annual Value [ton-hrs] Cooling Minimum Value [ton] Timestamp of Minimum {TIMESTAMP} Cooling Maximum Value [ton] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Water

Annual Value [ft3] Minimum Value [ft3/min] Timestamp of Minimum {TIMESTAMP} Maximum Value [ft3/min] Timestamp of Maximum {TIMESTAMP}
Water:Facility 3549.45 0.00 02-JAN-02:15 0.01 08-JAN-08:45
Water:Plant 3549.45 0.00 02-JAN-02:15 0.01 08-JAN-08:45
WaterSystems:Water 3549.45 0.00 02-JAN-02:15 0.01 08-JAN-08:45
Water Heater:WaterSystems:Water 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
MainsWater:Facility 3549.45 0.00 02-JAN-02:15 0.01 08-JAN-08:45
MainsWater:Plant 3549.45 0.00 02-JAN-02:15 0.01 08-JAN-08:45
WaterSystems:MainsWater 3549.45 0.00 02-JAN-02:15 0.01 08-JAN-08:45
Water Heater:WaterSystems:MainsWater 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Domestic Hot Water:WaterSystems:Water 3549.45 0.00 02-JAN-02:15 0.01 08-JAN-08:45
Domestic Hot Water:WaterSystems:MainsWater 3549.45 0.00 02-JAN-02:15 0.01 08-JAN-08:45


Annual and Peak Values - Other by Weight/Mass

Annual Value [lb] Minimum Value [lb/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [lb/s] Timestamp of Maximum {TIMESTAMP}
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [ft3] Minimum Value [ft3/min] Timestamp of Minimum {TIMESTAMP} Maximum Value [ft3/min] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [gal] Minimum Value [gal] Timestamp of Minimum {TIMESTAMP} Maximum Value [gal] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Other

Annual Value [kBtu] Minimum Value [Btu/h] Timestamp of Minimum {TIMESTAMP} Maximum Value [Btu/h] Timestamp of Maximum {TIMESTAMP}
PlantLoopHeatingDemand:Facility 9997.97 99.49 08-AUG-03:00 2326.76 05-FEB-08:15
PlantLoopHeatingDemand:Plant 9997.97 99.49 08-AUG-03:00 2326.76 05-FEB-08:15
WaterSystems:PlantLoopHeatingDemand 9997.97 99.49 08-AUG-03:00 2326.76 05-FEB-08:15
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
FuelOil#1:Facility 18166.78 0.00 01-JAN-00:15 8346.58 11-FEB-08:15
FuelOil#1:Plant 18166.78 0.00 01-JAN-00:15 8346.58 11-FEB-08:15
WaterSystems:FuelOil#1 18166.78 0.00 01-JAN-00:15 8346.58 11-FEB-08:15
Water Heater:WaterSystems:FuelOil#1 18166.78 0.00 01-JAN-00:15 8346.58 11-FEB-08:15
EnergyTransfer:Facility 50668.30 99.49 07-AUG-03:00 29862.88 30-JUN-18:15
EnergyTransfer:Building 19980.31 0.00 01-JAN-13:45 13239.07 30-JUN-17:45
EnergyTransfer:Zone:LIVING_UNIT1 19980.31 0.00 01-JAN-13:45 13239.07 30-JUN-17:45
Heating:EnergyTransfer 12779.12 0.00 01-JAN-13:45 10745.10 24-JAN-06:00
Heating:EnergyTransfer:Zone:LIVING_UNIT1 12779.12 0.00 01-JAN-13:45 10745.10 24-JAN-06:00
Cooling:EnergyTransfer 7201.19 0.00 01-JAN-00:15 13239.07 30-JUN-17:45
Cooling:EnergyTransfer:Zone:LIVING_UNIT1 7201.19 0.00 01-JAN-00:15 13239.07 30-JUN-17:45
EnergyTransfer:Zone:ATTIC_UNIT1 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:ATTIC_UNIT1 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:ATTIC_UNIT1 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Plant 9997.97 99.49 08-AUG-03:00 2326.76 05-FEB-08:15
WaterSystems:EnergyTransfer 9997.97 99.49 08-AUG-03:00 2326.76 05-FEB-08:15
Domestic Hot Water:WaterSystems:EnergyTransfer 9997.97 99.49 08-AUG-03:00 2326.76 05-FEB-08:15
EnergyTransfer:HVAC 20690.02 0.00 01-JAN-13:45 15176.99 30-JUN-17:45
HeatingCoils:EnergyTransfer 12123.25 0.00 01-JAN-13:45 10193.72 24-JAN-06:00
FuelOil#2:Facility 15542.63 0.00 01-JAN-13:45 13068.87 24-JAN-06:00
FuelOil#2:HVAC 15542.63 0.00 01-JAN-13:45 13068.87 24-JAN-06:00
Heating:FuelOil#2 15542.63 0.00 01-JAN-13:45 13068.87 24-JAN-06:00
CoolingCoils:EnergyTransfer 8566.77 0.00 01-JAN-00:15 15176.99 30-JUN-17:45



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2019-02-14 08:57:21

Annual Building Sensible Heat Gain Components

HVAC Zone Eq & Other Sensible Air Heating [kBtu] HVAC Zone Eq & Other Sensible Air Cooling [ton-hrs] HVAC Terminal Unit Sensible Air Heating [kBtu] HVAC Terminal Unit Sensible Air Cooling [ton-hrs] HVAC Input Heated Surface Heating [kBtu] HVAC Input Cooled Surface Cooling [ton-hrs] People Sensible Heat Addition [kBtu] Lights Sensible Heat Addition [kBtu] Equipment Sensible Heat Addition [kBtu] Window Heat Addition [kBtu] Interzone Air Transfer Heat Addition [kBtu] Infiltration Heat Addition [kBtu] Opaque Surface Conduction and Other Heat Addition [kBtu] Equipment Sensible Heat Removal [kBtu] Window Heat Removal [kBtu] Interzone Air Transfer Heat Removal [kBtu] Infiltration Heat Removal [kBtu] Opaque Surface Conduction and Other Heat Removal [kBtu]
LIVING_UNIT1 0.000 0.000 12778.985 -599.69 0.000 0.000 4612.481 6069.367 19176.458 9255.320 0.000 74.418 0.000 0.000 -8992.23 0.000 -20553.07 -15220.63
ATTIC_UNIT1 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 677.050 6335.871 0.000 0.000 0.000 -7012.92 -0.02
Total Facility 0.000 0.000 12778.985 -599.69 0.000 0.000 4612.481 6069.367 19176.458 9255.320 0.000 751.468 6335.871 0.000 -8992.23 0.000 -27565.99 -15220.65


Peak Cooling Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [Btu/h] HVAC Zone Eq & Other Sensible Air Cooling [ton] HVAC Terminal Unit Sensible Air Heating [Btu/h] HVAC Terminal Unit Sensible Air Cooling [ton] HVAC Input Heated Surface Heating [Btu/h] HVAC Input Cooled Surface Cooling [ton] People Sensible Heat Addition [Btu/h] Lights Sensible Heat Addition [Btu/h] Equipment Sensible Heat Addition [Btu/h] Window Heat Addition [Btu/h] Interzone Air Transfer Heat Addition [Btu/h] Infiltration Heat Addition [Btu/h] Opaque Surface Conduction and Other Heat Addition [Btu/h] Equipment Sensible Heat Removal [Btu/h] Window Heat Removal [Btu/h] Interzone Air Transfer Heat Removal [Btu/h] Infiltration Heat Removal [Btu/h] Opaque Surface Conduction and Other Heat Removal [Btu/h]
LIVING_UNIT1 30-JUN-17:34 0.00 0.00 0.00 -1.1 0.00 0.00 393.78 1324.27 2968.43 3657.92 0.00 599.59 4298.23 0.00 0.00 0.00 0.00 0.00
ATTIC_UNIT1 - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 30-JUN-17:34 0.00 0.00 0.00 -1.1 0.00 0.00 393.78 1324.27 2968.43 3657.92 0.00 599.59 6233.51 0.00 0.00 0.00 -1935.3 0.00


Peak Heating Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [Btu/h] HVAC Zone Eq & Other Sensible Air Cooling [ton] HVAC Terminal Unit Sensible Air Heating [Btu/h] HVAC Terminal Unit Sensible Air Cooling [ton] HVAC Input Heated Surface Heating [Btu/h] HVAC Input Cooled Surface Cooling [ton] People Sensible Heat Addition [Btu/h] Lights Sensible Heat Addition [Btu/h] Equipment Sensible Heat Addition [Btu/h] Window Heat Addition [Btu/h] Interzone Air Transfer Heat Addition [Btu/h] Infiltration Heat Addition [Btu/h] Opaque Surface Conduction and Other Heat Addition [Btu/h] Equipment Sensible Heat Removal [Btu/h] Window Heat Removal [Btu/h] Interzone Air Transfer Heat Removal [Btu/h] Infiltration Heat Removal [Btu/h] Opaque Surface Conduction and Other Heat Removal [Btu/h]
LIVING_UNIT1 24-JAN-06:00 0.00 0.00 10744.73 0.00 0.00 0.00 789.46 848.89 1758.42 0.00 0.00 0.00 0.00 0.00 -3177.4 0.00 -5225.8 -5738.3
ATTIC_UNIT1 - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 24-JAN-06:00 0.00 0.00 10744.73 0.00 0.00 0.00 789.46 848.89 1758.42 0.00 0.00 188.64 0.00 0.00 -3177.4 0.00 -5225.8 -5926.9



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2019-02-14 08:57:21

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [ft3/min] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [ft3/min] System Primary Airflow - Vps [ft3/min] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [ft3/min] Percent Outdoor Air - %OA
CENTRAL SYSTEM_UNIT1 561.731 3.00 3.00 1.00 59.9933 561.731 0.107 1.000 59.9933 0.11


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [ft3/min] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [ft3/min] System Primary Airflow - Vps [ft3/min] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [ft3/min] Percent Outdoor Air - %OA
CENTRAL SYSTEM_UNIT1 207.129 3.00 3.00 1.00 59.9933 207.129 1.000 1.000 59.9933 0.29


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [ft3/min-person] Zone Population - Pz Area Outdoor Air Rate - Ra [ft3/min-ft2] Zone Floor Area - Az [ft2] Breathing Zone Outdoor Airflow - Vbz [ft3/min] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [ft3/min] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [ft3/min]
LIVING_UNIT1 CENTRAL SYSTEM_UNIT1 0.000000 3.00 0.000000 3565.64 59.9933 1.000 59.9933 1.000 59.9933


System Ventilation Parameters

People Outdoor Air Rate - Rp [ft3/min-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [ft3/min-ft2] Sum of Zone Floor Area - Az-sum [ft2] Breathing Zone Outdoor Airflow - Vbz [ft3/min] Cooling Zone Outdoor Airflow - Voz-clg [ft3/min] Heating Zone Outdoor Airflow - Voz-htg [ft3/min]
CENTRAL SYSTEM_UNIT1 0.000000 3.00 0.000000 3565.64 59.9933 59.9933 59.9933


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [ft3/min] Zone Discharge Airflow - Vdz [ft3/min] Minimum Zone Primary Airflow - Vpz-min [ft3/min] Zone Outdoor Airflow Cooling - Voz-clg [ft3/min] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
LIVING_UNIT1 CENTRAL SYSTEM_UNIT1   561.731 561.7306 534.7347 59.9933 0.000 1.000 0.000 0.000 0.000 0.000 1.000


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [ft3/min] System Primary Airflow - Vps [ft3/min] Sum of Zone Discharge Airflow - Vdz-sum [ft3/min] Sum of Min Zone Primary Airflow - Vpz-min [ft3/min] Zone Outdoor Airflow Cooling - Voz-clg [ft3/min] Zone Ventilation Efficiency - Evz-min
CENTRAL SYSTEM_UNIT1 561.73 561.731 561.73 534.7347 59.9933 1.000


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [ft3/min] Zone Discharge Airflow - Vdz [ft3/min] Minimum Zone Primary Airflow - Vpz-min [ft3/min] Zone Outdoor Airflow Heating - Voz-htg [ft3/min] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
LIVING_UNIT1 CENTRAL SYSTEM_UNIT1   207.129 207.129 207.129 59.9933 0.290 1.000 0.000 0.000 0.000 0.000 1.000


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [ft3/min] System Primary Airflow - Vps [ft3/min] Sum of Zone Discharge Airflow - Vdz-sum [ft3/min] Sum of Min Zone Primary Airflow - Vpz-min [ft3/min] Zone Outdoor Airflow Heating - Voz-htg [ft3/min] Zone Ventilation Efficiency - Evz-min
CENTRAL SYSTEM_UNIT1 207.13 207.129 207.13 207.13 59.9933 1.000



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2019-02-14 08:57:21

Sec1.1A-General Information

Data
Weather File ANNUAL ** San Francisco Intl Ap CA USA TMY3 WMO#=724940
Total gross floor area [ft2] 4754.19
Principal Heating Source Additional Fuel


EAp2-1. Space Usage Type

Space Area [ft2] Regularly Occupied Area [ft2] Unconditioned Area [ft2] Typical Hours/Week in Operation [hr/wk]
LIVING_UNIT1 3565.64 3565.64 0.00 168.00
ATTIC_UNIT1 1188.55 0.00 1188.55 0.00
Totals 4754.19 3565.64 1188.55  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 0.00
Number of hours cooling loads not met 0.00
Number of hours not met 0.00


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [kWh] Electric Demand [W] Natural Gas Energy Use [therm] Natural Gas Demand [Btu/h] Additional Energy Use [kBtu] Additional Demand [Btu/h]
Interior Lighting 1777.57 522.47 0.00 0.00 0.00 0.00
Exterior Lighting 255.08 59.98 0.00 0.00 0.00 0.00
Space Heating 0.00 0.00 0.00 0.00 15542.63 13068.87
Space Cooling 526.42 931.51 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Fans-Interior 319.26 211.30 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 0.00 0.00 0.00 0.00 18166.78 0.00
Receptacle Equipment 8769.56 1460.14 0.00 0.00 0.00 0.00
Interior Lighting-Process 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 11647.89   0.00   33709.40  


EAp2-6. Energy Use Summary

Process Subtotal [kBtu] Total Energy Use [kBtu]
Electricity 29942.93 39770.74
Natural Gas 0.00 0.00
Additional 0.00 33709.40
Total 29942.93 73480.15


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [kBtu]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [kWh/ft2]
Interior Lighting 0.37
Space Heating 0.00
Space Cooling 0.11
Fans-Interior 0.07
Service Water Heating 0.00
Receptacle Equipment 1.84
Miscellaneous 0.05
Subtotal 2.45


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [kWh/ft2]
Space Heating 0.00
Service Water Heating 0.00
Miscellaneous 0.00
Subtotal 0.00


EAp2-17c. Energy Use Intensity - Additional

Additional [kBtu/ft2]
Miscellaneous 7.08
Subtotal 7.08


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 8.26
Space Heating 21.15
Space Cooling 2.45
Fans-Interior 1.48
Service Water Heating 24.72
Receptacle Equipment 40.75
Miscellaneous 1.19



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2019-02-14 08:57:21

AirTerminal:SingleDuct:Uncontrolled

Design Size Maximum Air Flow Rate [ft3/min]
ZONEDIRECTAIR_UNIT1 561.73
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

AirLoopHVAC

Design Supply Air Flow Rate [ft3/min]
CENTRAL SYSTEM_UNIT1 561.73
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Cooling:DX:SingleSpeed

Design Size Rated Air Flow Rate [ft3/min] Design Size Gross Rated Total Cooling Capacity [ton] Design Size Gross Rated Sensible Heat Ratio
DX COOLING COIL_UNIT1 561.73 1.25 0.798655
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

AirLoopHVAC:UnitaryHeatCool

Supply Air Flow Rate [ft3/min] Supply Air Flow Rate During Heating Operation [ft3/min] Supply Air Flow Rate During Cooling Operation [ft3/min] Nominal Heating Capacity [Btu/h] Nominal Cooling Capacity [ton] Fraction of Supply Air Flow That Goes Through the Controlling Zone
ACANDF_UNIT1 561.73 561.73 561.73 13365.24 1.25 1.00
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Fan:OnOff

Design Size Maximum Flow Rate [ft3/min]
SUPPLY FAN_UNIT1 561.73
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Heating:Fuel

Design Size Nominal Capacity [Btu/h]
MAIN FUEL HEATING COIL_UNIT1 13365.24
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

PlantLoop

Maximum Loop Flow Rate [ft3/min] Plant Loop Volume [ft3]
DHW LOOP_UNIT1 1.05 19.62
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Pump:VariableSpeed

Design Flow Rate [ft3/min]
MAINS PRESSURE_UNIT1 1.05
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

WaterHeater:Mixed

Maximum Heater Capacity [Btu/h] Use Side Design Flow Rate [ft3/min]
WATER HEATER_UNIT1 38002.17 1.05
User-Specified values were used. Design Size values were used if no User-Specified values were provided.


Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2019-02-14 08:57:21

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

Possible Shadow Receivers
OVERHANG_SDR_1.UNIT1 WALL_SDR_1.UNIT1 |
Mir-OVERHANG_SDR_1.UNIT1 OVERHANG_SDR_2.UNIT1 | WALL_SDR_1.UNIT1 | WALL_SDR_2.UNIT1 | ROOF_RIGHT_UNIT1 |
OVERHANG_SDR_2.UNIT1 WALL_SDR_2.UNIT1 |
Mir-OVERHANG_SDR_2.UNIT1 WALL_SDR_2.UNIT1 | ROOF_RIGHT_UNIT1 |
WALL_SDR_1.UNIT1 OVERHANG_SDR_1.UNIT1 | OVERHANG_SDR_2.UNIT1 |
WALL_SDR_2.UNIT1 OVERHANG_SDR_2.UNIT1 |
BGWALL_UPPER_SDR OVERHANG_SDR_1.UNIT1 | OVERHANG_SDR_2.UNIT1 |


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
WALL_LDF_1.UNIT1 WINDOW_LDF_1.UNIT1 |
WALL_SDR_1.UNIT1 WINDOW_SDR_1.UNIT1 |
WALL_LDB_1.UNIT1 WINDOW_LDB_1.UNIT1 | DOOR_LDB_UNIT1 |
WALL_SDL_1.UNIT1 WINDOW_SDL_1.UNIT1 |
WALL_LDF_2.UNIT1 WINDOW_LDF_2.UNIT1 |
WALL_SDR_2.UNIT1 WINDOW_SDR_2.UNIT1 |
WALL_LDB_2.UNIT1 WINDOW_LDB_2.UNIT1 |
WALL_SDL_2.UNIT1 WINDOW_SDL_2.UNIT1 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2019-02-14 08:57:21

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: FANSPLIT

For: CENTRAL SYSTEM_UNIT1

Timestamp: 2019-02-14 08:57:21

Custom Monthly Report

AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] AIR SYSTEM FAN ELECTRIC ENERGY {FOR HOURS SHOWN} [kWh] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY {HOURS NON-ZERO} [HOURS] AIR SYSTEM FAN ELECTRIC ENERGY {FOR HOURS SHOWN} [kWh] AIR SYSTEM FAN ELECTRIC ENERGY [kWh]
January 0.000 0.000 678.692 44.835 44.835
February 45.175 2.010 461.612 26.871 28.880
March 112.242 5.256 406.125 21.876 27.132
April 128.875 7.002 341.427 14.531 21.533
May 222.518 12.300 201.312 7.351 19.651
June 253.299 18.287 212.403 6.999 25.286
July 299.225 19.012 143.208 2.755 21.768
August 325.062 23.880 124.937 2.141 26.021
September 331.100 24.117 113.086 2.015 26.132
October 227.683 12.893 235.988 7.242 20.135
November 66.712 2.290 417.021 19.406 21.696
December 9.575 0.154 588.875 36.033 36.187
           
Annual Sum or Average 2021.467 127.201 3924.686 192.055 319.256
Minimum of Months 0.000 0.000 113.086 2.015 19.651
Maximum of Months 331.100 24.117 678.692 44.835 44.835



Table of Contents

Report: COILLOADS

For: MAIN FUEL HEATING COIL_UNIT1

Timestamp: 2019-02-14 08:57:21

Custom Monthly Report

HEATING COIL TOTAL HEATING RATE [Invalid/Undefined] HEATING COIL AIR HEATING RATE [Btu/h] COOLING COIL TOTAL COOLING RATE [Invalid/Undefined]
January 0.00 3801.27 0.00
February 0.00 2522.31 0.00
March 0.00 1854.72 0.00
April 0.00 1273.06 0.00
May 0.00 623.21 0.00
June 0.00 613.16 0.00
July 0.00 233.62 0.00
August 0.00 181.53 0.00
September 0.00 176.57 0.00
October 0.00 613.97 0.00
November 0.00 1700.18 0.00
December 0.00 3055.00 0.00
       
Annual Sum or Average 0.00 1382.95 0.00
Minimum of Months 0.00 176.57 0.00
Maximum of Months 0.00 3801.27 0.00



Table of Contents

Report: COILLOADS

For: DX COOLING COIL_UNIT1

Timestamp: 2019-02-14 08:57:21

Custom Monthly Report

HEATING COIL TOTAL HEATING RATE [Invalid/Undefined] HEATING COIL AIR HEATING RATE [Invalid/Undefined] COOLING COIL TOTAL COOLING RATE [ton]
January 0.00 0.00 0.00
February 0.00 0.00 0.02
March 0.00 0.00 0.04
April 0.00 0.00 0.05
May 0.00 0.00 0.09
June 0.00 0.00 0.14
July 0.00 0.00 0.14
August 0.00 0.00 0.18
September 0.00 0.00 0.19
October 0.00 0.00 0.10
November 0.00 0.00 0.02
December 0.00 0.00 0.00
       
Annual Sum or Average 0.00 0.00 0.08
Minimum of Months 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.19



Table of Contents

Report: WATER HEATER: LOADS

For: WATER HEATER_UNIT1

Timestamp: 2019-02-14 08:57:21

Custom Monthly Report

WATER HEATER TOTAL DEMAND RATE [Invalid/Undefined] WATER HEATER TOTAL DEMAND ENERGY [Invalid/Undefined] WATER HEATER HEATING RATE [Btu/h] WATER HEATER HEATING ENERGY [kBtu]
January 0.00 0.00 1747.08 1300.75
February 0.00 0.00 1750.09 1176.89
March 0.00 0.00 1726.09 1285.12
April 0.00 0.00 1695.95 1221.95
May 0.00 0.00 1642.54 1222.92
June 0.00 0.00 1601.95 1154.22
July 0.00 0.00 1574.21 1172.04
August 0.00 0.00 1564.09 1164.51
September 0.00 0.00 1581.52 1139.50
October 0.00 0.00 1621.92 1207.56
November 0.00 0.00 1672.05 1204.73
December 0.00 0.00 1723.54 1283.22
         
Annual Sum or Average 0.00 0.00 1657.89 14533.42
Minimum of Months 0.00 0.00 1564.09 1139.50
Maximum of Months 0.00 0.00 1750.09 1300.75