Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 19:11

Tabular Output Report in Format: HTML

Building: High-Rise Apartment

Environment: Vancouver Int'l BC CAN WYEC2-B-94238 WMO#=718920

Simulation Timestamp: 2015-09-09 19:12:21


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:21

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 4506.85 575.11 638.37
Net Site Energy 4506.85 575.11 638.37
Total Source Energy 10208.19 1302.65 1445.94
Net Source Energy 10208.19 1302.65 1445.94


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 7836.48
Net Conditioned Building Area 7059.89
Unconditioned Building Area 776.58


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 213.87 772.80 0.00 0.00 0.00 0.00
Cooling 99.13 0.00 0.00 0.00 0.00 0.00
Interior Lighting 296.56 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 162.51 0.00 0.00 0.00 0.00 0.00
Interior Equipment 1137.32 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 553.30 0.00 0.00 0.00 0.00 0.00
Pumps 52.23 0.00 0.00 0.00 0.00 0.00
Heat Rejection 4.24 0.00 0.00 0.00 0.00 313.33
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 1178.71 0.00 0.00 0.00 4778.51
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 2555.34 1951.51 0.00 0.00 0.00 5091.84
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating Boiler 0.00 772.80 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
  Other 213.87 0.00 0.00 0.00 0.00 0.00
Cooling General 99.13 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 242.55 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 54.01 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 162.51 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 1137.32 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 553.30 0.00 0.00 0.00 0.00 0.00
Pumps General 52.23 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 4.24 0.00 0.00 0.00 0.00 313.33
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 1178.71 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 4778.51
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 65.03 0.00 0.00 0.00 0.00 0.00
HVAC 130.71 276.42 0.00 0.00 0.00 0.72
Other 161.10 0.00 0.00 0.00 0.00 0.00
Total 361.95 276.42 0.00 0.00 0.00 0.72


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 58.58 0.00 0.00 0.00 0.00 0.00
HVAC 117.75 249.03 0.00 0.00 0.00 0.65
Other 145.13 0.00 0.00 0.00 0.00 0.00
Total 326.08 249.03 0.00 0.00 0.00 0.65


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 2555.34 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 2555.34 100.00
     
Total On-Site and Utility Electric Sources 2555.34 100.00
Total Electricity End Uses 2555.34 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 5091.84 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 5091.84 100.00
Total Water End Uses 5091.84 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 200.25
Time Setpoint Not Met During Occupied Cooling 6.25
Time Not Comfortable Based on Simple ASHRAE 55-2004 728.50


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |

COMPONENTS OF PEAK ELECTRICAL DEMAND

| Meter |

COMPONENTS OF PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:21

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 19:11
RunPeriod Vancouver Int'l BC CAN WYEC2-B-94238 WMO#=718920
Weather File Vancouver Int'l BC CAN WYEC2-B-94238 WMO#=718920
Latitude [deg] 49.18
Longitude [deg] -123.2
Elevation [m] 2.00
Time Zone -8.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3855.02 1411.96 515.55 1411.96 515.55
Window Opening Area [m2] 1150.39 423.59 152.73 423.59 150.48
Window-Wall Ratio [%] 29.84 30.00 29.62 30.00 29.19


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3752.84 1411.96 464.46 1411.96 464.46
Window Opening Area [m2] 1125.85 423.59 139.34 423.59 139.34
Window-Wall Ratio [%] 30.00 30.00 30.00 30.00 30.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
OFFICE 88.25 Yes Yes 268.96 1.00 58.52 17.56 29.5362 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 4.47 6.7128   0.0000
F2 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F3 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F4 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
M SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
M CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 13.4255   0.0000
F6 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F7 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F8 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F9 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
T SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   264.3872
Total 7836.48     23884.04   3855.02 1150.39 4.3335 39.48 8.6291
Conditioned Total 7059.89     21517.16   3752.84 1125.85 3.9979 35.57 6.6700
Unconditioned Total 776.58     2366.87   102.18 24.54 7.3840   26.4387
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:21

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 16-DEC-17:15 16-DEC-18:00 - - - 11-JUL-17:15
Heating 63322.24 183438.27 0.00 0.00 0.00 0.00
Cooling 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 11327.17 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 10364.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 57042.02 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 17544.92 0.00 0.00 0.00 0.00 0.00
Pumps 1677.22 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 74728.68 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 163265.22 258166.95 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating Boiler 0.00 183438.27 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 9220.52 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 2106.65 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 10364.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 57042.02 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 17544.92 0.00 0.00 0.00 0.00 0.00
Pumps General 1677.22 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 74728.68 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:21

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 677.34 837.72 0.00 0.00 0.00
Cooling 313.94 0.00 0.00 0.00 0.00
Interior Lighting 939.20 0.00 0.00 0.00 0.00
Exterior Lighting 514.68 0.00 0.00 0.00 0.00
Interior Equipment 3601.91 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 1752.29 0.00 0.00 0.00 0.00
Pumps 165.40 0.00 0.00 0.00 0.00
Heat Rejection 13.44 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 1277.72 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 8092.75 2115.44 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 95.94 118.66 0.00 0.00 0.00
Cooling 44.47 0.00 0.00 0.00 0.00
Interior Lighting 133.03 0.00 0.00 0.00 0.00
Exterior Lighting 72.90 0.00 0.00 0.00 0.00
Interior Equipment 510.19 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 248.20 0.00 0.00 0.00 0.00
Pumps 23.43 0.00 0.00 0.00 0.00
Heat Rejection 1.90 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 180.98 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1146.30 299.64 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 95.94 118.66 0.00 0.00 0.00
Cooling 44.47 0.00 0.00 0.00 0.00
Interior Lighting 133.03 0.00 0.00 0.00 0.00
Exterior Lighting 72.90 0.00 0.00 0.00 0.00
Interior Equipment 510.19 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 248.20 0.00 0.00 0.00 0.00
Pumps 23.43 0.00 0.00 0.00 0.00
Heat Rejection 1.90 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 180.98 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1146.30 299.64 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:21

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
VANCOUVER INT'L ANN HTG 99.6% CONDNS DB -7.00 0.00 -7.00 Wetbulb [C] 2.90 100.00
VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 25.00 7.60 18.20 Wetbulb [C] 3.60 300.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:21

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 270.00 180.00  
F2 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F2 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F2 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F2 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F2 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F2 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F3 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F3 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F3 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F3 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F3 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F3 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F4 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F4 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F4 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F4 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F4 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F4 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
M WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F6 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F6 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F6 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F6 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F6 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F6 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F7 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F7 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F7 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F7 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F7 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F7 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F8 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F8 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F8 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F8 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F8 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F8 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F9 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F9 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F9 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F9 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F9 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F9 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.30 0.269 0.283 77.66 0.00 0.00  


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL SWA 180.00 90.00 S
GWINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G WWALL SWA 270.00 90.00 W
GWINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL NWA 0.00 90.00 N
GWINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G WWALL NWA 270.00 90.00 W
GWINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL SEA 180.00 90.00 S
GWINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G EWALL SEA 90.00 90.00 E
GWINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL NEA 0.00 90.00 N
GWINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G EWALL NEA 90.00 90.00 E
GWINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL N1A 0.00 90.00 N
GWINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL N2A 0.00 90.00 N
GWINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL S1A 180.00 90.00 S
GWINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL S2A 180.00 90.00 S
GWINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No G WWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.48_SHGC_0.40 3.36 0.00 0.00 3.36 3.36 2.653 0.426 0.308     No G EWALL C 90.00 90.00 E
F2WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 WWALL SWA 270.00 90.00 W
F2WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL SWA 180.00 90.00 S
F2WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL NWA 0.00 90.00 N
F2WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 WWALL NWA 270.00 90.00 W
F2WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 EWALL SEA 90.00 90.00 E
F2WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL SEA 180.00 90.00 S
F2WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL NEA 0.00 90.00 N
F2WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 EWALL NEA 90.00 90.00 E
F2WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL N1A 0.00 90.00 N
F2WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL N2A 0.00 90.00 N
F2WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL S1A 180.00 90.00 S
F2WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL S2A 180.00 90.00 S
F2WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F2 WWALL C 270.00 90.00 W
F2WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F2 EWALL C 90.00 90.00 E
F3WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 WWALL SWA 270.00 90.00 W
F3WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL SWA 180.00 90.00 S
F3WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL NWA 0.00 90.00 N
F3WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 WWALL NWA 270.00 90.00 W
F3WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 EWALL SEA 90.00 90.00 E
F3WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL SEA 180.00 90.00 S
F3WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL NEA 0.00 90.00 N
F3WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 EWALL NEA 90.00 90.00 E
F3WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL N1A 0.00 90.00 N
F3WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL N2A 0.00 90.00 N
F3WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL S1A 180.00 90.00 S
F3WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL S2A 180.00 90.00 S
F3WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F3 WWALL C 270.00 90.00 W
F3WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F3 EWALL C 90.00 90.00 E
F4WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 WWALL SWA 270.00 90.00 W
F4WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL SWA 180.00 90.00 S
F4WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL NWA 0.00 90.00 N
F4WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 WWALL NWA 270.00 90.00 W
F4WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 EWALL SEA 90.00 90.00 E
F4WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL SEA 180.00 90.00 S
F4WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL NEA 0.00 90.00 N
F4WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 EWALL NEA 90.00 90.00 E
F4WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL N1A 0.00 90.00 N
F4WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL N2A 0.00 90.00 N
F4WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL S1A 180.00 90.00 S
F4WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL S2A 180.00 90.00 S
F4WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F4 WWALL C 270.00 90.00 W
F4WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F4 EWALL C 90.00 90.00 E
MWINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M WWALL SWA 270.00 90.00 W
MWINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL SWA 180.00 90.00 S
MWINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL NWA 0.00 90.00 N
MWINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M WWALL NWA 270.00 90.00 W
MWINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M EWALL SEA 90.00 90.00 E
MWINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL SEA 180.00 90.00 S
MWINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL NEA 0.00 90.00 N
MWINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M EWALL NEA 90.00 90.00 E
MWINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL N1A 0.00 90.00 N
MWINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL N2A 0.00 90.00 N
MWINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL S1A 180.00 90.00 S
MWINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL S2A 180.00 90.00 S
MWINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No M WWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No M EWALL C 90.00 90.00 E
F6WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 WWALL SWA 270.00 90.00 W
F6WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL SWA 180.00 90.00 S
F6WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL NWA 0.00 90.00 N
F6WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 WWALL NWA 270.00 90.00 W
F6WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 EWALL SEA 90.00 90.00 E
F6WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL SEA 180.00 90.00 S
F6WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL NEA 0.00 90.00 N
F6WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 EWALL NEA 90.00 90.00 E
F6WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL N1A 0.00 90.00 N
F6WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL N2A 0.00 90.00 N
F6WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL S1A 180.00 90.00 S
F6WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL S2A 180.00 90.00 S
F6WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F6 WWALL C 270.00 90.00 W
F6WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F6 EWALL C 90.00 90.00 E
F7WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 WWALL SWA 270.00 90.00 W
F7WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL SWA 180.00 90.00 S
F7WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL NWA 0.00 90.00 N
F7WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 WWALL NWA 270.00 90.00 W
F7WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 EWALL SEA 90.00 90.00 E
F7WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL SEA 180.00 90.00 S
F7WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL NEA 0.00 90.00 N
F7WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 EWALL NEA 90.00 90.00 E
F7WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL N1A 0.00 90.00 N
F7WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL N2A 0.00 90.00 N
F7WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL S1A 180.00 90.00 S
F7WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL S2A 180.00 90.00 S
F7WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F7 WWALL C 270.00 90.00 W
F7WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F7 EWALL C 90.00 90.00 E
F8WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 WWALL SWA 270.00 90.00 W
F8WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL SWA 180.00 90.00 S
F8WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL NWA 0.00 90.00 N
F8WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 WWALL NWA 270.00 90.00 W
F8WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 EWALL SEA 90.00 90.00 E
F8WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL SEA 180.00 90.00 S
F8WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL NEA 0.00 90.00 N
F8WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 EWALL NEA 90.00 90.00 E
F8WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL N1A 0.00 90.00 N
F8WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL N2A 0.00 90.00 N
F8WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL S1A 180.00 90.00 S
F8WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL S2A 180.00 90.00 S
F8WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F8 WWALL C 270.00 90.00 W
F8WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F8 EWALL C 90.00 90.00 E
F9WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 WWALL SWA 270.00 90.00 W
F9WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL SWA 180.00 90.00 S
F9WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL NWA 0.00 90.00 N
F9WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 WWALL NWA 270.00 90.00 W
F9WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 EWALL SEA 90.00 90.00 E
F9WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL SEA 180.00 90.00 S
F9WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL NEA 0.00 90.00 N
F9WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 EWALL NEA 90.00 90.00 E
F9WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL N1A 0.00 90.00 N
F9WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL N2A 0.00 90.00 N
F9WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL S1A 180.00 90.00 S
F9WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL S2A 180.00 90.00 S
F9WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F9 WWALL C 270.00 90.00 W
F9WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F9 EWALL C 90.00 90.00 E
TWINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T WWALL SWA 270.00 90.00 W
TWINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL SWA 180.00 90.00 S
TWINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL NWA 0.00 90.00 N
TWINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T WWALL NWA 270.00 90.00 W
TWINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T EWALL SEA 90.00 90.00 E
TWINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL SEA 180.00 90.00 S
TWINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL NEA 0.00 90.00 N
TWINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T EWALL NEA 90.00 90.00 E
TWINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL N1A 0.00 90.00 N
TWINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL N2A 0.00 90.00 N
TWINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL S1A 180.00 90.00 S
TWINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL S2A 180.00 90.00 S
TWINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No T WWALL C 270.00 90.00 W
TWINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No T EWALL C 90.00 90.00 E
Total or Average           1150.39 2.653 0.426 0.308              
North Total or Average           423.59 2.653 0.426 0.308              
Non-North Total or Average           726.80 2.653 0.426 0.308              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:21

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:21

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
G SW APARTMENT_LIGHTS_HARDWIRED G SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G NW APARTMENT_LIGHTS_HARDWIRED G NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
OFFICE_LIGHTS_HARDWIRED OFFICE 14.7681 88.25 1303.26 GeneralLights LTG_OFF_SCH 62.05 168.00 61.07 0.0000 Y 14.94
G NE APARTMENT_LIGHTS_HARDWIRED G NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G N1 APARTMENT_LIGHTS_HARDWIRED G N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G N2 APARTMENT_LIGHTS_HARDWIRED G N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G S1 APARTMENT_LIGHTS_HARDWIRED G S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G S2 APARTMENT_LIGHTS_HARDWIRED G S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G CORRIDOR_LIGHTS_HARDWIRED G CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F2 SW APARTMENT_LIGHTS_HARDWIRED F2 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 NW APARTMENT_LIGHTS_HARDWIRED F2 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 SE APARTMENT_LIGHTS_HARDWIRED F2 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 NE APARTMENT_LIGHTS_HARDWIRED F2 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 N1 APARTMENT_LIGHTS_HARDWIRED F2 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 N2 APARTMENT_LIGHTS_HARDWIRED F2 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 S1 APARTMENT_LIGHTS_HARDWIRED F2 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 S2 APARTMENT_LIGHTS_HARDWIRED F2 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 CORRIDOR_LIGHTS_HARDWIRED F2 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F3 SW APARTMENT_LIGHTS_HARDWIRED F3 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 NW APARTMENT_LIGHTS_HARDWIRED F3 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 SE APARTMENT_LIGHTS_HARDWIRED F3 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 NE APARTMENT_LIGHTS_HARDWIRED F3 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 N1 APARTMENT_LIGHTS_HARDWIRED F3 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 N2 APARTMENT_LIGHTS_HARDWIRED F3 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 S1 APARTMENT_LIGHTS_HARDWIRED F3 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 S2 APARTMENT_LIGHTS_HARDWIRED F3 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 CORRIDOR_LIGHTS_HARDWIRED F3 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F4 SW APARTMENT_LIGHTS_HARDWIRED F4 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 NW APARTMENT_LIGHTS_HARDWIRED F4 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 SE APARTMENT_LIGHTS_HARDWIRED F4 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 NE APARTMENT_LIGHTS_HARDWIRED F4 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 N1 APARTMENT_LIGHTS_HARDWIRED F4 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 N2 APARTMENT_LIGHTS_HARDWIRED F4 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 S1 APARTMENT_LIGHTS_HARDWIRED F4 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 S2 APARTMENT_LIGHTS_HARDWIRED F4 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 CORRIDOR_LIGHTS_HARDWIRED F4 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
M SW APARTMENT_LIGHTS_HARDWIRED M SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M NW APARTMENT_LIGHTS_HARDWIRED M NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M SE APARTMENT_LIGHTS_HARDWIRED M SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M NE APARTMENT_LIGHTS_HARDWIRED M NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M N1 APARTMENT_LIGHTS_HARDWIRED M N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M N2 APARTMENT_LIGHTS_HARDWIRED M N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M S1 APARTMENT_LIGHTS_HARDWIRED M S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M S2 APARTMENT_LIGHTS_HARDWIRED M S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M CORRIDOR_LIGHTS_HARDWIRED M CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F6 SW APARTMENT_LIGHTS_HARDWIRED F6 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 NW APARTMENT_LIGHTS_HARDWIRED F6 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 SE APARTMENT_LIGHTS_HARDWIRED F6 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 NE APARTMENT_LIGHTS_HARDWIRED F6 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 N1 APARTMENT_LIGHTS_HARDWIRED F6 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 N2 APARTMENT_LIGHTS_HARDWIRED F6 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 S1 APARTMENT_LIGHTS_HARDWIRED F6 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 S2 APARTMENT_LIGHTS_HARDWIRED F6 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 CORRIDOR_LIGHTS_HARDWIRED F6 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F7 SW APARTMENT_LIGHTS_HARDWIRED F7 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 NW APARTMENT_LIGHTS_HARDWIRED F7 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 SE APARTMENT_LIGHTS_HARDWIRED F7 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 NE APARTMENT_LIGHTS_HARDWIRED F7 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 N1 APARTMENT_LIGHTS_HARDWIRED F7 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 N2 APARTMENT_LIGHTS_HARDWIRED F7 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 S1 APARTMENT_LIGHTS_HARDWIRED F7 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 S2 APARTMENT_LIGHTS_HARDWIRED F7 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 CORRIDOR_LIGHTS_HARDWIRED F7 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F8 SW APARTMENT_LIGHTS_HARDWIRED F8 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 NW APARTMENT_LIGHTS_HARDWIRED F8 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 SE APARTMENT_LIGHTS_HARDWIRED F8 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 NE APARTMENT_LIGHTS_HARDWIRED F8 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 N1 APARTMENT_LIGHTS_HARDWIRED F8 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 N2 APARTMENT_LIGHTS_HARDWIRED F8 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 S1 APARTMENT_LIGHTS_HARDWIRED F8 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 S2 APARTMENT_LIGHTS_HARDWIRED F8 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 CORRIDOR_LIGHTS_HARDWIRED F8 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F9 SW APARTMENT_LIGHTS_HARDWIRED F9 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 NW APARTMENT_LIGHTS_HARDWIRED F9 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 SE APARTMENT_LIGHTS_HARDWIRED F9 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 NE APARTMENT_LIGHTS_HARDWIRED F9 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 N1 APARTMENT_LIGHTS_HARDWIRED F9 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 N2 APARTMENT_LIGHTS_HARDWIRED F9 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 S1 APARTMENT_LIGHTS_HARDWIRED F9 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 S2 APARTMENT_LIGHTS_HARDWIRED F9 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 CORRIDOR_LIGHTS_HARDWIRED F9 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
T SW APARTMENT_LIGHTS_HARDWIRED T SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T NW APARTMENT_LIGHTS_HARDWIRED T NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T SE APARTMENT_LIGHTS_HARDWIRED T SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T NE APARTMENT_LIGHTS_HARDWIRED T NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T N1 APARTMENT_LIGHTS_HARDWIRED T N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T N2 APARTMENT_LIGHTS_HARDWIRED T N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T S1 APARTMENT_LIGHTS_HARDWIRED T S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T S2 APARTMENT_LIGHTS_HARDWIRED T S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T CORRIDOR_LIGHTS_HARDWIRED T CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
G SW APARTMENT_LIGHTS_PLUGIN G SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G NW APARTMENT_LIGHTS_PLUGIN G NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
OFFICE_LIGHTS_PLUGIN OFFICE 14.7681 88.25 1303.26 GeneralLights-plugin LTG_OFF_SCH 62.05 168.00 61.07 0.0000 Y 14.94
G NE APARTMENT_LIGHTS_PLUGIN G NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G N1 APARTMENT_LIGHTS_PLUGIN G N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G N2 APARTMENT_LIGHTS_PLUGIN G N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G S1 APARTMENT_LIGHTS_PLUGIN G S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G S2 APARTMENT_LIGHTS_PLUGIN G S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 SW APARTMENT_LIGHTS_PLUGIN F2 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 NW APARTMENT_LIGHTS_PLUGIN F2 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 SE APARTMENT_LIGHTS_PLUGIN F2 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 NE APARTMENT_LIGHTS_PLUGIN F2 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 N1 APARTMENT_LIGHTS_PLUGIN F2 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 N2 APARTMENT_LIGHTS_PLUGIN F2 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 S1 APARTMENT_LIGHTS_PLUGIN F2 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 S2 APARTMENT_LIGHTS_PLUGIN F2 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 SW APARTMENT_LIGHTS_PLUGIN F3 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 NW APARTMENT_LIGHTS_PLUGIN F3 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 SE APARTMENT_LIGHTS_PLUGIN F3 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 NE APARTMENT_LIGHTS_PLUGIN F3 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 N1 APARTMENT_LIGHTS_PLUGIN F3 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 N2 APARTMENT_LIGHTS_PLUGIN F3 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 S1 APARTMENT_LIGHTS_PLUGIN F3 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 S2 APARTMENT_LIGHTS_PLUGIN F3 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 SW APARTMENT_LIGHTS_PLUGIN F4 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 NW APARTMENT_LIGHTS_PLUGIN F4 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 SE APARTMENT_LIGHTS_PLUGIN F4 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 NE APARTMENT_LIGHTS_PLUGIN F4 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 N1 APARTMENT_LIGHTS_PLUGIN F4 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 N2 APARTMENT_LIGHTS_PLUGIN F4 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 S1 APARTMENT_LIGHTS_PLUGIN F4 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 S2 APARTMENT_LIGHTS_PLUGIN F4 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M SW APARTMENT_LIGHTS_PLUGIN M SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M NW APARTMENT_LIGHTS_PLUGIN M NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M SE APARTMENT_LIGHTS_PLUGIN M SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M NE APARTMENT_LIGHTS_PLUGIN M NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M N1 APARTMENT_LIGHTS_PLUGIN M N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M N2 APARTMENT_LIGHTS_PLUGIN M N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M S1 APARTMENT_LIGHTS_PLUGIN M S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M S2 APARTMENT_LIGHTS_PLUGIN M S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M CORRIDOR_LIGHTS_PLUGIN M CORRIDOR 6.7128 77.66 521.30 GeneralLights-plugin LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F6 SW APARTMENT_LIGHTS_PLUGIN F6 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 NW APARTMENT_LIGHTS_PLUGIN F6 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 SE APARTMENT_LIGHTS_PLUGIN F6 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 NE APARTMENT_LIGHTS_PLUGIN F6 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 N1 APARTMENT_LIGHTS_PLUGIN F6 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 N2 APARTMENT_LIGHTS_PLUGIN F6 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 S1 APARTMENT_LIGHTS_PLUGIN F6 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 S2 APARTMENT_LIGHTS_PLUGIN F6 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 SW APARTMENT_LIGHTS_PLUGIN F7 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 NW APARTMENT_LIGHTS_PLUGIN F7 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 SE APARTMENT_LIGHTS_PLUGIN F7 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 NE APARTMENT_LIGHTS_PLUGIN F7 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 N1 APARTMENT_LIGHTS_PLUGIN F7 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 N2 APARTMENT_LIGHTS_PLUGIN F7 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 S1 APARTMENT_LIGHTS_PLUGIN F7 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 S2 APARTMENT_LIGHTS_PLUGIN F7 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 SW APARTMENT_LIGHTS_PLUGIN F8 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 NW APARTMENT_LIGHTS_PLUGIN F8 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 SE APARTMENT_LIGHTS_PLUGIN F8 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 NE APARTMENT_LIGHTS_PLUGIN F8 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 N1 APARTMENT_LIGHTS_PLUGIN F8 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 N2 APARTMENT_LIGHTS_PLUGIN F8 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 S1 APARTMENT_LIGHTS_PLUGIN F8 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 S2 APARTMENT_LIGHTS_PLUGIN F8 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 SW APARTMENT_LIGHTS_PLUGIN F9 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 NW APARTMENT_LIGHTS_PLUGIN F9 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 SE APARTMENT_LIGHTS_PLUGIN F9 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 NE APARTMENT_LIGHTS_PLUGIN F9 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 N1 APARTMENT_LIGHTS_PLUGIN F9 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 N2 APARTMENT_LIGHTS_PLUGIN F9 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 S1 APARTMENT_LIGHTS_PLUGIN F9 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 S2 APARTMENT_LIGHTS_PLUGIN F9 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T SW APARTMENT_LIGHTS_PLUGIN T SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T NW APARTMENT_LIGHTS_PLUGIN T NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T SE APARTMENT_LIGHTS_PLUGIN T SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T NE APARTMENT_LIGHTS_PLUGIN T NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T N1 APARTMENT_LIGHTS_PLUGIN T N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T N2 APARTMENT_LIGHTS_PLUGIN T N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T S1 APARTMENT_LIGHTS_PLUGIN T S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T S2 APARTMENT_LIGHTS_PLUGIN T S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
Interior Lighting Total   2.2679 14974.03 33959.19               296.56


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 10364.00 AstronomicalClock -   83.53 83.53 162.51
Exterior Lighting Total 10364.00           162.51



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:21

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
CENTRAL BOILER Boiler:HotWater 236149.76 0.75    
CENTRAL TOWER EvaporativeFluidCooler:SingleSpeed 188919.81      


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
HEAT PUMP COOLING MODE AIRLOOP G SW Coil:Cooling:WaterToAirHeatPump:EquationFit   3301.54 2450.76 850.78 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NW Coil:Cooling:WaterToAirHeatPump:EquationFit   2296.82 1672.42 624.40 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP OFFICE Coil:Cooling:WaterToAirHeatPump:EquationFit   5084.36 3812.04 1272.32 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NE Coil:Cooling:WaterToAirHeatPump:EquationFit   1656.97 1180.74 476.23 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1012.32 696.39 315.93 0.69 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1015.61 696.74 318.87 0.69 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2446.12 1794.31 651.81 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2538.35 1866.42 671.93 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4248.57 3174.90 1073.67 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3026.90 2226.05 800.85 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4274.09 3193.58 1080.51 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2281.79 1658.55 623.24 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1458.60 1031.49 427.11 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1425.63 1006.67 418.96 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3187.56 2364.19 823.37 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3223.36 2392.18 831.18 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4284.54 3193.70 1090.84 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3079.39 2258.76 820.63 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4017.07 2983.73 1033.33 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2341.05 1697.58 643.47 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1523.54 1077.63 445.90 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1490.39 1052.69 437.70 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3246.84 2404.97 841.86 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3264.27 2418.61 845.66 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4295.85 3195.65 1100.20 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3093.12 2263.46 829.66 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4002.79 2965.89 1036.91 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2351.59 1700.56 651.03 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1541.54 1088.83 452.71 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1508.27 1063.84 444.43 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3263.55 2413.90 849.65 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3278.36 2425.48 852.88 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4329.52 3216.35 1113.17 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3127.84 2285.60 842.24 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4036.10 2986.42 1049.68 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2382.94 1720.68 662.26 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1578.24 1114.73 463.51 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1544.93 1089.72 455.21 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3300.66 2439.50 861.16 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3315.10 2450.79 864.31 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4283.41 3175.71 1107.69 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3081.49 2245.71 835.78 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   3993.20 2948.45 1044.75 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2335.57 1680.64 654.94 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1537.18 1081.85 455.33 0.70 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1503.94 1056.98 446.96 0.70 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3257.67 2403.14 854.53 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3272.10 2414.42 857.68 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4265.64 3157.79 1107.84 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3063.90 2228.66 835.24 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   3978.07 2932.71 1045.36 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2316.23 1662.79 653.45 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1523.20 1069.83 453.37 0.70 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1490.01 1045.05 444.96 0.70 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3242.58 2388.91 853.67 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3257.02 2400.19 856.83 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4260.80 3150.40 1110.40 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3059.92 2222.54 837.38 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   3975.22 2926.97 1048.25 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2309.84 1655.30 654.54 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1523.36 1068.69 454.67 0.70 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1490.25 1044.01 446.24 0.70 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3240.17 2384.83 855.34 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3254.64 2396.13 858.51 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4335.87 3205.47 1130.40 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3138.96 2280.68 858.27 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4033.47 2968.41 1065.06 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2309.30 1652.43 656.88 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1596.30 1122.64 473.65 0.70 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1562.89 1097.70 465.19 0.70 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3289.87 2420.97 868.90 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3304.39 2432.30 872.08 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5209.30 3880.80 1328.50 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3789.16 2781.96 1007.21 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4834.41 3589.33 1245.08 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2848.36 2061.68 786.69 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2104.10 1500.74 603.36 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2106.64 1502.64 604.00 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   4233.06 3155.17 1077.89 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   4247.16 3166.21 1080.94 0.75 0.00    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
None            


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
HEAT PUMP HEATING MODE AIRLOOP G SW Coil:Heating:WaterToAirHeatPump:EquationFit   3301.54 0.00
HEAT PUMP HEATING MODE AIRLOOP G NW Coil:Heating:WaterToAirHeatPump:EquationFit   2296.82 0.00
HEAT PUMP HEATING MODE AIRLOOP OFFICE Coil:Heating:WaterToAirHeatPump:EquationFit   5084.36 0.00
HEAT PUMP HEATING MODE AIRLOOP G NE Coil:Heating:WaterToAirHeatPump:EquationFit   1656.97 0.00
HEAT PUMP HEATING MODE AIRLOOP G N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1012.32 0.00
HEAT PUMP HEATING MODE AIRLOOP G N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1015.61 0.00
HEAT PUMP HEATING MODE AIRLOOP G S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2446.12 0.00
HEAT PUMP HEATING MODE AIRLOOP G S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2538.35 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4248.57 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3026.90 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4274.09 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2281.79 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1458.60 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1425.63 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3187.56 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3223.36 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4284.54 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3079.39 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4017.07 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2341.05 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1523.54 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1490.39 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3246.84 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3264.27 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4295.85 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3093.12 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4002.79 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2351.59 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1541.54 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1508.27 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3263.55 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3278.36 0.00
HEAT PUMP HEATING MODE AIRLOOP M SW Coil:Heating:WaterToAirHeatPump:EquationFit   4329.52 0.00
HEAT PUMP HEATING MODE AIRLOOP M NW Coil:Heating:WaterToAirHeatPump:EquationFit   3127.84 0.00
HEAT PUMP HEATING MODE AIRLOOP M SE Coil:Heating:WaterToAirHeatPump:EquationFit   4036.10 0.00
HEAT PUMP HEATING MODE AIRLOOP M NE Coil:Heating:WaterToAirHeatPump:EquationFit   2382.94 0.00
HEAT PUMP HEATING MODE AIRLOOP M N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1578.24 0.00
HEAT PUMP HEATING MODE AIRLOOP M N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1544.93 0.00
HEAT PUMP HEATING MODE AIRLOOP M S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3300.66 0.00
HEAT PUMP HEATING MODE AIRLOOP M S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3315.10 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4283.41 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3081.49 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SE Coil:Heating:WaterToAirHeatPump:EquationFit   3993.20 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2335.57 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1537.18 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1503.94 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3257.67 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3272.10 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4265.64 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3063.90 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SE Coil:Heating:WaterToAirHeatPump:EquationFit   3978.07 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2316.23 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1523.20 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1490.01 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3242.58 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3257.02 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4260.80 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3059.92 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SE Coil:Heating:WaterToAirHeatPump:EquationFit   3975.22 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2309.84 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1523.36 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1490.25 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3240.17 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3254.64 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4335.87 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3138.96 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4033.47 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2309.30 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1596.30 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1562.89 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3289.87 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3304.39 0.00
HEAT PUMP HEATING MODE AIRLOOP T SW Coil:Heating:WaterToAirHeatPump:EquationFit   5209.30 0.00
HEAT PUMP HEATING MODE AIRLOOP T NW Coil:Heating:WaterToAirHeatPump:EquationFit   3789.16 0.00
HEAT PUMP HEATING MODE AIRLOOP T SE Coil:Heating:WaterToAirHeatPump:EquationFit   4834.41 0.00
HEAT PUMP HEATING MODE AIRLOOP T NE Coil:Heating:WaterToAirHeatPump:EquationFit   2848.36 0.00
HEAT PUMP HEATING MODE AIRLOOP T N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2104.10 0.00
HEAT PUMP HEATING MODE AIRLOOP T N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2106.64 0.00
HEAT PUMP HEATING MODE AIRLOOP T S1 Coil:Heating:WaterToAirHeatPump:EquationFit   4233.06 0.00
HEAT PUMP HEATING MODE AIRLOOP T S2 Coil:Heating:WaterToAirHeatPump:EquationFit   4247.16 0.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW Coil:Heating:Electric   2947.58 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW Coil:Heating:Electric   2952.99 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE Coil:Heating:Electric   3720.93 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE Coil:Heating:Electric   2949.94 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 Coil:Heating:Electric   2241.39 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 Coil:Heating:Electric   2241.32 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 Coil:Heating:Electric   2232.33 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 Coil:Heating:Electric   2238.56 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW Coil:Heating:Electric   2880.32 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW Coil:Heating:Electric   2880.67 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE Coil:Heating:Electric   2896.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE Coil:Heating:Electric   2878.42 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 Coil:Heating:Electric   1997.40 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 Coil:Heating:Electric   1997.35 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 Coil:Heating:Electric   1999.80 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 Coil:Heating:Electric   2000.97 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW Coil:Heating:Electric   2901.57 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW Coil:Heating:Electric   2902.68 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE Coil:Heating:Electric   2902.50 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE Coil:Heating:Electric   2901.54 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 Coil:Heating:Electric   1973.08 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 Coil:Heating:Electric   1973.05 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 Coil:Heating:Electric   1972.75 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 Coil:Heating:Electric   1972.92 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW Coil:Heating:Electric   2969.72 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW Coil:Heating:Electric   2971.33 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE Coil:Heating:Electric   2969.70 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE Coil:Heating:Electric   2971.09 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 Coil:Heating:Electric   2004.57 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 Coil:Heating:Electric   2004.56 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 Coil:Heating:Electric   2003.47 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 Coil:Heating:Electric   2003.49 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW Coil:Heating:Electric   3015.16 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW Coil:Heating:Electric   3015.94 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE Coil:Heating:Electric   3015.70 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE Coil:Heating:Electric   3016.46 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 Coil:Heating:Electric   2020.36 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 Coil:Heating:Electric   2020.37 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 Coil:Heating:Electric   2020.04 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 Coil:Heating:Electric   2020.06 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW Coil:Heating:Electric   3114.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW Coil:Heating:Electric   3116.38 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE Coil:Heating:Electric   3115.91 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE Coil:Heating:Electric   3117.55 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 Coil:Heating:Electric   2093.44 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 Coil:Heating:Electric   2093.47 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 Coil:Heating:Electric   2092.24 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 Coil:Heating:Electric   2092.27 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW Coil:Heating:Electric   3186.83 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW Coil:Heating:Electric   3188.27 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE Coil:Heating:Electric   3188.57 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE Coil:Heating:Electric   3190.01 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 Coil:Heating:Electric   2142.68 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 Coil:Heating:Electric   2142.73 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 Coil:Heating:Electric   2141.69 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 Coil:Heating:Electric   2141.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW Coil:Heating:Electric   3261.15 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW Coil:Heating:Electric   3262.16 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE Coil:Heating:Electric   3263.40 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE Coil:Heating:Electric   3264.41 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 Coil:Heating:Electric   2196.48 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 Coil:Heating:Electric   2196.54 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 Coil:Heating:Electric   2195.91 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 Coil:Heating:Electric   2195.96 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW Coil:Heating:Electric   3449.99 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW Coil:Heating:Electric   3448.43 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE Coil:Heating:Electric   3452.73 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE Coil:Heating:Electric   3451.16 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 Coil:Heating:Electric   2356.83 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 Coil:Heating:Electric   2356.90 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 Coil:Heating:Electric   2358.39 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 Coil:Heating:Electric   2358.46 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW Coil:Heating:Electric   4058.25 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW Coil:Heating:Electric   4063.02 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE Coil:Heating:Electric   4061.13 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE Coil:Heating:Electric   4065.90 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 Coil:Heating:Electric   3005.80 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 Coil:Heating:Electric   3005.87 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 Coil:Heating:Electric   2998.08 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 Coil:Heating:Electric   2998.16 1.00


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
AIRLOOP G SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 250.54 1160.84 1.00 General
AIRLOOP G NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.15 170.20 1160.84 1.00 General
AIRLOOP OFFICE SUPPLY FAN Fan:OnOff 0.54 622.50 0.34 391.83 1160.84 1.00 General
AIRLOOP G NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 120.17 1160.84 1.00 General
AIRLOOP G N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.06 70.27 1160.84 1.00 General
AIRLOOP G N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.06 70.26 1160.84 1.00 General
AIRLOOP G S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 181.73 1160.84 1.00 General
AIRLOOP G S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 189.35 1160.84 1.00 General
AIRLOOP F2 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 325.97 1160.84 1.00 General
AIRLOOP F2 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 227.62 1160.84 1.00 General
AIRLOOP F2 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 327.70 1160.84 1.00 General
AIRLOOP F2 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.15 169.70 1160.84 1.00 General
AIRLOOP F2 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.09 104.83 1160.84 1.00 General
AIRLOOP F2 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.09 102.27 1160.84 1.00 General
AIRLOOP F2 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 241.29 1160.84 1.00 General
AIRLOOP F2 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 244.24 1160.84 1.00 General
AIRLOOP F3 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 327.40 1160.84 1.00 General
AIRLOOP F3 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 230.57 1160.84 1.00 General
AIRLOOP F3 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 305.04 1160.84 1.00 General
AIRLOOP F3 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.15 173.36 1160.84 1.00 General
AIRLOOP F3 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.09 109.41 1160.84 1.00 General
AIRLOOP F3 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.09 106.83 1160.84 1.00 General
AIRLOOP F3 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 245.26 1160.84 1.00 General
AIRLOOP F3 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 246.70 1160.84 1.00 General
AIRLOOP F4 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 327.20 1160.84 1.00 General
AIRLOOP F4 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 230.70 1160.84 1.00 General
AIRLOOP F4 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 302.76 1160.84 1.00 General
AIRLOOP F4 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.15 173.34 1160.84 1.00 General
AIRLOOP F4 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 110.40 1160.84 1.00 General
AIRLOOP F4 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.09 107.82 1160.84 1.00 General
AIRLOOP F4 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 245.96 1160.84 1.00 General
AIRLOOP F4 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 247.18 1160.84 1.00 General
AIRLOOP M SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 329.05 1160.84 1.00 General
AIRLOOP M NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 232.72 1160.84 1.00 General
AIRLOOP M SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 304.60 1160.84 1.00 General
AIRLOOP M NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.15 175.19 1160.84 1.00 General
AIRLOOP M N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 112.96 1160.84 1.00 General
AIRLOOP M N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 110.38 1160.84 1.00 General
AIRLOOP M S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 248.46 1160.84 1.00 General
AIRLOOP M S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 249.65 1160.84 1.00 General
AIRLOOP F6 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 324.49 1160.84 1.00 General
AIRLOOP F6 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 228.28 1160.84 1.00 General
AIRLOOP F6 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 300.32 1160.84 1.00 General
AIRLOOP F6 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.15 170.76 1160.84 1.00 General
AIRLOOP F6 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.09 109.42 1160.84 1.00 General
AIRLOOP F6 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.09 106.85 1160.84 1.00 General
AIRLOOP F6 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 244.45 1160.84 1.00 General
AIRLOOP F6 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 245.64 1160.84 1.00 General
AIRLOOP F7 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 322.36 1160.84 1.00 General
AIRLOOP F7 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 226.27 1160.84 1.00 General
AIRLOOP F7 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 298.43 1160.84 1.00 General
AIRLOOP F7 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.15 168.69 1160.84 1.00 General
AIRLOOP F7 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.09 108.06 1160.84 1.00 General
AIRLOOP F7 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.09 105.51 1160.84 1.00 General
AIRLOOP F7 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 242.80 1160.84 1.00 General
AIRLOOP F7 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 243.99 1160.84 1.00 General
AIRLOOP F8 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 321.36 1160.84 1.00 General
AIRLOOP F8 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 225.44 1160.84 1.00 General
AIRLOOP F8 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 297.61 1160.84 1.00 General
AIRLOOP F8 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 167.74 1160.84 1.00 General
AIRLOOP F8 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.09 107.85 1160.84 1.00 General
AIRLOOP F8 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.09 105.32 1160.84 1.00 General
AIRLOOP F8 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 242.24 1160.84 1.00 General
AIRLOOP F8 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 243.43 1160.84 1.00 General
AIRLOOP F9 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 326.96 1160.84 1.00 General
AIRLOOP F9 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 231.36 1160.84 1.00 General
AIRLOOP F9 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 301.63 1160.84 1.00 General
AIRLOOP F9 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 167.27 1160.84 1.00 General
AIRLOOP F9 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 113.37 1160.84 1.00 General
AIRLOOP F9 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 110.80 1160.84 1.00 General
AIRLOOP F9 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 245.79 1160.84 1.00 General
AIRLOOP F9 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 246.99 1160.84 1.00 General
AIRLOOP T SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.34 397.52 1160.84 1.00 General
AIRLOOP T NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 283.26 1160.84 1.00 General
AIRLOOP T SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 366.95 1160.84 1.00 General
AIRLOOP T NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 209.16 1160.84 1.00 General
AIRLOOP T N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 148.94 1160.84 1.00 General
AIRLOOP T N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 149.14 1160.84 1.00 General
AIRLOOP T S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 323.17 1160.84 1.00 General
AIRLOOP T S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 324.34 1160.84 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
SHWSYS1 PUMP Pump:ConstantSpeed Intermittent 29891.00 0.0003 36.93 127739.32 0.30
PLANT CIRC PUMP Pump:ConstantSpeed Intermittent 224180.02 0.0051 1640.30 319344.75 0.90


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
SHWSYS1 WATER HEATER WaterHeater:Mixed 2.27 175842.64 0.80 0.00 0.00



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:21

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 2296.39 2755.66 0.180 0.216 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 24.66 0.01029
G NW APARTMENT 1560.03 1872.03 0.122 0.147 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 17:45:00 23.37 0.01029
OFFICE 3591.49 4309.78 0.281 0.338 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 24.81 0.01029
G NE APARTMENT 1101.40 1321.68 0.086 0.104 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 10:00:00 22.11 0.01029
G N1 APARTMENT 630.26 756.31 0.049 0.059 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 22.04 0.01029
G N2 APARTMENT 606.09 727.31 0.047 0.057 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 22.04 0.01029
G S1 APARTMENT 1665.73 1998.88 0.130 0.157 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 24.91 0.01029
G S2 APARTMENT 1735.52 2082.62 0.136 0.163 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 24.91 0.01029
F2 SW APARTMENT 2987.70 3585.24 0.234 0.281 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 24.66 0.01029
F2 NW APARTMENT 2086.35 2503.62 0.163 0.196 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 17:45:00 23.37 0.01029
F2 SE APARTMENT 3003.58 3604.30 0.235 0.282 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 24.81 0.01029
F2 NE APARTMENT 1555.37 1866.45 0.122 0.146 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 10:15:00 22.40 0.01029
F2 N1 APARTMENT 960.90 1153.07 0.075 0.090 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 22.04 0.01029
F2 N2 APARTMENT 937.37 1124.84 0.073 0.088 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 22.04 0.01029
F2 S1 APARTMENT 2211.65 2653.98 0.173 0.208 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 24.91 0.01029
F2 S2 APARTMENT 2238.71 2686.46 0.175 0.210 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 24.91 0.01029
F3 SW APARTMENT 3000.84 3601.01 0.235 0.282 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 24.66 0.01029
F3 NW APARTMENT 2113.33 2536.00 0.166 0.199 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 17:45:00 23.37 0.01029
F3 SE APARTMENT 2795.86 3355.03 0.219 0.263 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 24.81 0.01029
F3 NE APARTMENT 1588.95 1906.74 0.124 0.149 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 10:15:00 22.40 0.01029
F3 N1 APARTMENT 1002.85 1203.42 0.079 0.094 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 22.04 0.01029
F3 N2 APARTMENT 979.21 1175.05 0.077 0.092 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 22.04 0.01029
F3 S1 APARTMENT 2248.04 2697.65 0.176 0.211 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 24.91 0.01029
F3 S2 APARTMENT 2261.23 2713.47 0.177 0.213 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 24.91 0.01029
F4 SW APARTMENT 2998.97 3598.77 0.235 0.282 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 24.66 0.01029
F4 NW APARTMENT 2114.48 2537.38 0.166 0.199 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 17:45:00 23.37 0.01029
F4 SE APARTMENT 2774.95 3329.93 0.217 0.261 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 24.81 0.01029
F4 NE APARTMENT 1588.76 1906.51 0.124 0.149 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 10:15:00 22.40 0.01029
F4 N1 APARTMENT 1011.93 1214.31 0.079 0.095 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 22.04 0.01029
F4 N2 APARTMENT 988.27 1185.93 0.077 0.093 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 22.04 0.01029
F4 S1 APARTMENT 2254.39 2705.27 0.177 0.212 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 24.91 0.01029
F4 S2 APARTMENT 2265.60 2718.72 0.177 0.213 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 24.91 0.01029
M SW APARTMENT 3015.93 3619.11 0.236 0.283 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 24.66 0.01029
M NW APARTMENT 2133.07 2559.69 0.167 0.200 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 17:45:00 23.37 0.01029
M SE APARTMENT 2791.78 3350.13 0.219 0.262 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 24.81 0.01029
M NE APARTMENT 1605.69 1926.83 0.126 0.151 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 10:15:00 22.40 0.01029
M N1 APARTMENT 1035.36 1242.43 0.081 0.097 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 22.04 0.01029
M N2 APARTMENT 1011.69 1214.03 0.079 0.095 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 22.04 0.01029
M S1 APARTMENT 2277.28 2732.74 0.178 0.214 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 24.91 0.01029
M S2 APARTMENT 2288.20 2745.84 0.179 0.215 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 24.91 0.01029
F6 SW APARTMENT 2974.12 3568.94 0.233 0.280 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 24.66 0.01029
F6 NW APARTMENT 2092.35 2510.82 0.164 0.197 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 17:45:00 23.37 0.01029
F6 SE APARTMENT 2752.60 3303.12 0.216 0.259 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 24.81 0.01029
F6 NE APARTMENT 1565.07 1878.08 0.123 0.147 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 10:15:00 22.40 0.01029
F6 N1 APARTMENT 1002.88 1203.45 0.079 0.094 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 22.04 0.01029
F6 N2 APARTMENT 979.39 1175.26 0.077 0.092 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 22.04 0.01029
F6 S1 APARTMENT 2240.59 2688.71 0.175 0.211 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 24.91 0.01029
F6 S2 APARTMENT 2251.50 2701.80 0.176 0.212 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 24.91 0.01029
F7 SW APARTMENT 2954.57 3545.49 0.231 0.278 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 24.66 0.01029
F7 NW APARTMENT 2073.94 2488.72 0.162 0.195 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 17:45:00 23.37 0.01029
F7 SE APARTMENT 2735.21 3282.25 0.214 0.257 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 24.81 0.01029
F7 NE APARTMENT 1546.12 1855.35 0.121 0.145 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 10:15:00 22.40 0.01029
F7 N1 APARTMENT 990.48 1188.58 0.078 0.093 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 22.04 0.01029
F7 N2 APARTMENT 967.10 1160.52 0.076 0.091 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 22.04 0.01029
F7 S1 APARTMENT 2225.47 2670.57 0.174 0.209 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 24.91 0.01029
F7 S2 APARTMENT 2236.38 2683.65 0.175 0.210 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 24.91 0.01029
F8 SW APARTMENT 2945.43 3534.51 0.231 0.277 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 24.66 0.01029
F8 NW APARTMENT 2066.27 2479.52 0.162 0.194 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 17:45:00 23.37 0.01029
F8 SE APARTMENT 2727.70 3273.24 0.214 0.256 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 24.81 0.01029
F8 NE APARTMENT 1537.37 1844.84 0.120 0.144 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 10:15:00 22.40 0.01029
F8 N1 APARTMENT 988.57 1186.28 0.077 0.093 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 22.04 0.01029
F8 N2 APARTMENT 965.30 1158.35 0.076 0.091 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 22.04 0.01029
F8 S1 APARTMENT 2220.30 2664.36 0.174 0.209 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 24.91 0.01029
F8 S2 APARTMENT 2231.23 2677.48 0.175 0.210 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 24.91 0.01029
F9 SW APARTMENT 2996.70 3596.04 0.235 0.282 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 24.66 0.01029
F9 NW APARTMENT 2120.51 2544.62 0.166 0.199 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 17:45:00 23.37 0.01029
F9 SE APARTMENT 2764.59 3317.51 0.217 0.260 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 24.91 0.01029
F9 NE APARTMENT 1533.10 1839.72 0.120 0.144 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 10:15:00 22.40 0.01029
F9 N1 APARTMENT 1039.13 1246.96 0.081 0.098 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 22.04 0.01029
F9 N2 APARTMENT 1015.60 1218.72 0.080 0.095 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 19:00:00 22.04 0.01029
F9 S1 APARTMENT 2252.84 2703.40 0.176 0.212 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 25.00 0.01029
F9 S2 APARTMENT 2263.80 2716.55 0.177 0.213 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 25.00 0.01029
T SW APARTMENT 3643.40 4372.07 0.285 0.342 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 15:15:00 24.89 0.01029
T NW APARTMENT 2596.19 3115.43 0.203 0.244 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 17:00:00 23.94 0.01029
T SE APARTMENT 3363.21 4035.85 0.263 0.316 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 24.81 0.01029
T NE APARTMENT 1916.99 2300.38 0.150 0.180 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 10:45:00 22.97 0.01029
T N1 APARTMENT 1365.15 1638.17 0.107 0.128 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 14:45:00 25.00 0.01029
T N2 APARTMENT 1366.94 1640.33 0.107 0.128 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 14:30:00 25.00 0.01029
T S1 APARTMENT 2962.08 3554.50 0.232 0.278 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 24.91 0.01029
T S2 APARTMENT 2972.77 3567.32 0.233 0.279 VANCOUVER INT'L ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 24.91 0.01029


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1730.58 2076.70 0.077 0.092 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.00 0.00208
G NW APARTMENT 1735.16 2082.20 0.077 0.093 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.00 0.00208
OFFICE 2027.79 2433.35 0.090 0.108 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 18:45:00 -7.00 0.00208
G NE APARTMENT 1732.58 2079.10 0.077 0.093 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.00 0.00208
G N1 APARTMENT 1133.38 1360.06 0.050 0.061 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.00 0.00208
G N2 APARTMENT 1133.32 1359.99 0.050 0.061 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.00 0.00208
G S1 APARTMENT 1125.73 1350.87 0.050 0.060 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.00 0.00208
G S2 APARTMENT 1130.99 1357.19 0.050 0.060 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.00 0.00208
F2 SW APARTMENT 1673.74 2008.49 0.074 0.089 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F2 NW APARTMENT 1674.04 2008.84 0.074 0.089 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F2 SE APARTMENT 1687.62 2025.15 0.075 0.090 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F2 NE APARTMENT 1672.14 2006.56 0.074 0.089 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F2 N1 APARTMENT 927.08 1112.49 0.041 0.050 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F2 N2 APARTMENT 927.03 1112.43 0.041 0.050 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F2 S1 APARTMENT 929.10 1114.93 0.041 0.050 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F2 S2 APARTMENT 930.10 1116.12 0.041 0.050 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F3 SW APARTMENT 1691.72 2030.06 0.075 0.090 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F3 NW APARTMENT 1692.66 2031.19 0.075 0.090 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F3 SE APARTMENT 1692.51 2031.01 0.075 0.090 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F3 NE APARTMENT 1691.69 2030.03 0.075 0.090 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F3 N1 APARTMENT 906.51 1087.82 0.040 0.048 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F3 N2 APARTMENT 906.49 1087.79 0.040 0.048 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F3 S1 APARTMENT 906.24 1087.48 0.040 0.048 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F3 S2 APARTMENT 906.38 1087.65 0.040 0.048 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F4 SW APARTMENT 1749.36 2099.23 0.078 0.093 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F4 NW APARTMENT 1750.72 2100.86 0.078 0.093 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F4 SE APARTMENT 1749.34 2099.21 0.078 0.093 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F4 NE APARTMENT 1750.52 2100.62 0.078 0.093 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F4 N1 APARTMENT 933.15 1119.78 0.042 0.050 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F4 N2 APARTMENT 933.14 1119.77 0.042 0.050 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F4 S1 APARTMENT 932.21 1118.66 0.041 0.050 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F4 S2 APARTMENT 932.23 1118.68 0.041 0.050 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
M SW APARTMENT 1787.78 2145.34 0.080 0.095 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
M NW APARTMENT 1788.45 2146.14 0.080 0.096 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
M SE APARTMENT 1788.24 2145.89 0.080 0.095 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
M NE APARTMENT 1788.89 2146.66 0.080 0.096 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
M N1 APARTMENT 946.51 1135.81 0.042 0.051 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
M N2 APARTMENT 946.52 1135.82 0.042 0.051 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
M S1 APARTMENT 946.24 1135.49 0.042 0.051 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
M S2 APARTMENT 946.25 1135.50 0.042 0.051 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F6 SW APARTMENT 1872.00 2246.40 0.083 0.100 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F6 NW APARTMENT 1873.39 2248.07 0.083 0.100 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F6 SE APARTMENT 1872.99 2247.59 0.083 0.100 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F6 NE APARTMENT 1874.38 2249.25 0.083 0.100 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F6 N1 APARTMENT 1008.31 1209.97 0.045 0.054 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F6 N2 APARTMENT 1008.33 1210.00 0.045 0.054 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F6 S1 APARTMENT 1007.29 1208.75 0.045 0.054 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F6 S2 APARTMENT 1007.32 1208.78 0.045 0.054 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F7 SW APARTMENT 1932.97 2319.56 0.086 0.103 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F7 NW APARTMENT 1934.19 2321.02 0.086 0.103 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F7 SE APARTMENT 1934.44 2321.33 0.086 0.103 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F7 NE APARTMENT 1935.66 2322.79 0.086 0.103 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F7 N1 APARTMENT 1049.95 1259.94 0.047 0.056 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F7 N2 APARTMENT 1049.99 1259.99 0.047 0.056 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F7 S1 APARTMENT 1049.11 1258.94 0.047 0.056 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F7 S2 APARTMENT 1049.15 1258.98 0.047 0.056 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F8 SW APARTMENT 1995.82 2394.99 0.089 0.107 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F8 NW APARTMENT 1996.68 2396.01 0.089 0.107 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F8 SE APARTMENT 1997.73 2397.27 0.089 0.107 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F8 NE APARTMENT 1998.58 2398.30 0.089 0.107 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F8 N1 APARTMENT 1095.45 1314.54 0.049 0.059 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F8 N2 APARTMENT 1095.50 1314.60 0.049 0.059 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F8 S1 APARTMENT 1094.96 1313.96 0.049 0.058 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F8 S2 APARTMENT 1095.01 1314.01 0.049 0.058 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F9 SW APARTMENT 2155.52 2586.62 0.096 0.115 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F9 NW APARTMENT 2154.20 2585.04 0.096 0.115 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F9 SE APARTMENT 2157.83 2589.40 0.096 0.115 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F9 NE APARTMENT 2156.51 2587.81 0.096 0.115 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F9 N1 APARTMENT 1231.05 1477.26 0.055 0.066 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F9 N2 APARTMENT 1231.11 1477.33 0.055 0.066 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F9 S1 APARTMENT 1232.37 1478.84 0.055 0.066 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
F9 S2 APARTMENT 1232.43 1478.91 0.055 0.066 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
T SW APARTMENT 2669.90 3203.89 0.119 0.143 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
T NW APARTMENT 2673.94 3208.73 0.119 0.143 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
T SE APARTMENT 2672.34 3206.80 0.119 0.143 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
T NE APARTMENT 2676.37 3211.65 0.119 0.143 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
T N1 APARTMENT 1779.86 2135.83 0.079 0.095 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
T N2 APARTMENT 1779.92 2135.91 0.079 0.095 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
T S1 APARTMENT 1773.33 2128.00 0.079 0.095 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208
T S2 APARTMENT 1773.40 2128.08 0.079 0.095 VANCOUVER INT'L ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -7.00 0.00208


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
AIRLOOP G SW 0.22 0.22 0.09 0.09
AIRLOOP G NW 0.15 0.15 0.09 0.09
AIRLOOP OFFICE 0.34 0.34 0.11 0.11
AIRLOOP G NE 0.10 0.10 0.09 0.09
AIRLOOP G N1 0.06 0.06 0.06 0.06
AIRLOOP G N2 0.06 0.06 0.06 0.06
AIRLOOP G S1 0.16 0.16 0.06 0.06
AIRLOOP G S2 0.16 0.16 0.06 0.06
AIRLOOP F2 SW 0.28 0.28 0.09 0.09
AIRLOOP F2 NW 0.20 0.20 0.09 0.09
AIRLOOP F2 SE 0.28 0.28 0.09 0.09
AIRLOOP F2 NE 0.15 0.15 0.09 0.09
AIRLOOP F2 N1 0.09 0.09 0.05 0.05
AIRLOOP F2 N2 0.09 0.09 0.05 0.05
AIRLOOP F2 S1 0.21 0.21 0.05 0.05
AIRLOOP F2 S2 0.21 0.21 0.05 0.05
AIRLOOP F3 SW 0.28 0.28 0.09 0.09
AIRLOOP F3 NW 0.20 0.20 0.09 0.09
AIRLOOP F3 SE 0.26 0.26 0.09 0.09
AIRLOOP F3 NE 0.15 0.15 0.09 0.09
AIRLOOP F3 N1 0.09 0.09 0.05 0.05
AIRLOOP F3 N2 0.09 0.09 0.05 0.05
AIRLOOP F3 S1 0.21 0.21 0.05 0.05
AIRLOOP F3 S2 0.21 0.21 0.05 0.05
AIRLOOP F4 SW 0.28 0.28 0.09 0.09
AIRLOOP F4 NW 0.20 0.20 0.09 0.09
AIRLOOP F4 SE 0.26 0.26 0.09 0.09
AIRLOOP F4 NE 0.15 0.15 0.09 0.09
AIRLOOP F4 N1 0.10 0.10 0.05 0.05
AIRLOOP F4 N2 0.09 0.09 0.05 0.05
AIRLOOP F4 S1 0.21 0.21 0.05 0.05
AIRLOOP F4 S2 0.21 0.21 0.05 0.05
AIRLOOP M SW 0.28 0.28 0.10 0.10
AIRLOOP M NW 0.20 0.20 0.10 0.10
AIRLOOP M SE 0.26 0.26 0.10 0.10
AIRLOOP M NE 0.15 0.15 0.10 0.10
AIRLOOP M N1 0.10 0.10 0.05 0.05
AIRLOOP M N2 0.10 0.10 0.05 0.05
AIRLOOP M S1 0.21 0.21 0.05 0.05
AIRLOOP M S2 0.22 0.22 0.05 0.05
AIRLOOP F6 SW 0.28 0.28 0.10 0.10
AIRLOOP F6 NW 0.20 0.20 0.10 0.10
AIRLOOP F6 SE 0.26 0.26 0.10 0.10
AIRLOOP F6 NE 0.15 0.15 0.10 0.10
AIRLOOP F6 N1 0.09 0.09 0.05 0.05
AIRLOOP F6 N2 0.09 0.09 0.05 0.05
AIRLOOP F6 S1 0.21 0.21 0.05 0.05
AIRLOOP F6 S2 0.21 0.21 0.05 0.05
AIRLOOP F7 SW 0.28 0.28 0.10 0.10
AIRLOOP F7 NW 0.19 0.19 0.10 0.10
AIRLOOP F7 SE 0.26 0.26 0.10 0.10
AIRLOOP F7 NE 0.15 0.15 0.10 0.10
AIRLOOP F7 N1 0.09 0.09 0.06 0.06
AIRLOOP F7 N2 0.09 0.09 0.06 0.06
AIRLOOP F7 S1 0.21 0.21 0.06 0.06
AIRLOOP F7 S2 0.21 0.21 0.06 0.06
AIRLOOP F8 SW 0.28 0.28 0.11 0.11
AIRLOOP F8 NW 0.19 0.19 0.11 0.11
AIRLOOP F8 SE 0.26 0.26 0.11 0.11
AIRLOOP F8 NE 0.14 0.14 0.11 0.11
AIRLOOP F8 N1 0.09 0.09 0.06 0.06
AIRLOOP F8 N2 0.09 0.09 0.06 0.06
AIRLOOP F8 S1 0.21 0.21 0.06 0.06
AIRLOOP F8 S2 0.21 0.21 0.06 0.06
AIRLOOP F9 SW 0.28 0.28 0.12 0.12
AIRLOOP F9 NW 0.20 0.20 0.12 0.12
AIRLOOP F9 SE 0.26 0.26 0.12 0.12
AIRLOOP F9 NE 0.14 0.14 0.12 0.12
AIRLOOP F9 N1 0.10 0.10 0.07 0.07
AIRLOOP F9 N2 0.10 0.10 0.07 0.07
AIRLOOP F9 S1 0.21 0.21 0.07 0.07
AIRLOOP F9 S2 0.21 0.21 0.07 0.07
AIRLOOP T SW 0.34 0.34 0.14 0.14
AIRLOOP T NW 0.24 0.24 0.14 0.14
AIRLOOP T SE 0.32 0.32 0.14 0.14
AIRLOOP T NE 0.18 0.18 0.14 0.14
AIRLOOP T N1 0.13 0.13 0.10 0.10
AIRLOOP T N2 0.13 0.13 0.10 0.10
AIRLOOP T S1 0.28 0.28 0.09 0.09
AIRLOOP T S2 0.28 0.28 0.09 0.09



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:21

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 1574.25 6419.50 105.50
G NW APARTMENT 964.25 7453.50 205.50
OFFICE 829.75 1086.25 7.25
G NE APARTMENT 899.00 7617.75 226.25
G N1 APARTMENT 427.50 7989.00 98.00
G N2 APARTMENT 421.50 8010.00 98.00
G S1 APARTMENT 1312.50 6620.75 54.75
G S2 APARTMENT 1387.00 6496.75 53.00
F2 SW APARTMENT 2598.75 5198.00 24.25
F2 NW APARTMENT 1534.25 6505.50 71.25
F2 SE APARTMENT 2854.00 4990.25 19.75
F2 NE APARTMENT 1404.25 6737.75 89.75
F2 N1 APARTMENT 995.00 7155.50 65.25
F2 N2 APARTMENT 974.00 7185.50 67.00
F2 S1 APARTMENT 2510.00 5084.75 21.25
F2 S2 APARTMENT 2545.75 5042.75 20.50
F3 SW APARTMENT 2792.50 5008.75 20.50
F3 NW APARTMENT 1713.25 6298.00 56.75
F3 SE APARTMENT 2809.75 5038.25 21.50
F3 NE APARTMENT 1554.00 6534.00 66.75
F3 N1 APARTMENT 1203.25 6831.75 49.25
F3 N2 APARTMENT 1180.50 6864.00 51.25
F3 S1 APARTMENT 2833.00 4727.50 18.25
F3 S2 APARTMENT 2844.25 4723.00 18.25
F4 SW APARTMENT 2855.25 4967.75 20.00
F4 NW APARTMENT 1791.50 6230.25 58.50
F4 SE APARTMENT 2824.50 5042.00 22.25
F4 NE APARTMENT 1650.00 6457.75 68.00
F4 N1 APARTMENT 1326.25 6678.75 57.50
F4 N2 APARTMENT 1294.00 6716.25 57.75
F4 S1 APARTMENT 2968.25 4639.25 19.25
F4 S2 APARTMENT 2965.50 4642.50 19.50
M SW APARTMENT 2845.75 4984.00 17.00
M NW APARTMENT 1794.00 6243.00 54.50
M SE APARTMENT 2803.75 5058.00 19.50
M NE APARTMENT 1644.50 6464.75 62.75
M N1 APARTMENT 1365.25 6634.75 54.75
M N2 APARTMENT 1333.00 6669.00 55.25
M S1 APARTMENT 2984.00 4632.25 18.25
M S2 APARTMENT 2982.00 4638.25 17.75
F6 SW APARTMENT 2668.75 5141.75 19.75
F6 NW APARTMENT 1635.00 6418.00 63.00
F6 SE APARTMENT 2629.25 5223.50 25.00
F6 NE APARTMENT 1471.25 6622.25 73.25
F6 N1 APARTMENT 1170.75 6846.50 56.00
F6 N2 APARTMENT 1142.00 6880.00 56.00
F6 S1 APARTMENT 2808.25 4804.25 20.75
F6 S2 APARTMENT 2802.25 4808.50 20.75
F7 SW APARTMENT 2543.75 5266.75 20.75
F7 NW APARTMENT 1528.25 6566.75 71.50
F7 SE APARTMENT 2504.25 5340.75 27.75
F7 NE APARTMENT 1356.00 6764.25 78.50
F7 N1 APARTMENT 1048.25 7000.25 55.50
F7 N2 APARTMENT 1023.00 7041.75 58.25
F7 S1 APARTMENT 2675.00 4957.75 23.00
F7 S2 APARTMENT 2667.75 4963.00 23.25
F8 SW APARTMENT 2437.75 5382.25 24.50
F8 NW APARTMENT 1433.75 6678.00 77.25
F8 SE APARTMENT 2384.50 5467.25 30.50
F8 NE APARTMENT 1251.75 6877.75 82.25
F8 N1 APARTMENT 958.25 7131.75 58.50
F8 N2 APARTMENT 931.75 7163.75 59.75
F8 S1 APARTMENT 2548.25 5101.00 25.75
F8 S2 APARTMENT 2538.75 5108.50 25.50
F9 SW APARTMENT 2291.50 5558.75 36.50
F9 NW APARTMENT 1371.00 6806.50 102.00
F9 SE APARTMENT 2235.00 5626.50 40.75
F9 NE APARTMENT 1190.50 6998.50 115.75
F9 N1 APARTMENT 911.75 7230.75 67.25
F9 N2 APARTMENT 885.75 7262.25 67.75
F9 S1 APARTMENT 2359.75 5319.25 28.25
F9 S2 APARTMENT 2352.25 5329.75 28.00
T SW APARTMENT 2379.75 6066.75 466.25
T NW APARTMENT 1763.00 7077.50 619.00
T SE APARTMENT 2390.50 6097.25 476.75
T NE APARTMENT 1746.75 7189.25 656.25
T N1 APARTMENT 1059.50 7383.75 216.25
T N2 APARTMENT 1055.75 7398.25 218.75
T S1 APARTMENT 2085.25 5801.50 104.50
T S2 APARTMENT 2081.00 5807.25 104.50
G CORRIDOR 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00
Facility 4159.75 8157.25 728.50
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 1.25 0.00 1.25 0.00
G NW APARTMENT 5.25 3.00 5.25 3.00
OFFICE 2.50 0.00 0.25 0.00
G NE APARTMENT 5.25 0.00 5.25 0.00
G N1 APARTMENT 6.50 2.50 6.50 2.50
G N2 APARTMENT 7.75 2.25 7.75 2.25
G S1 APARTMENT 4.75 0.00 4.75 0.00
G S2 APARTMENT 7.75 0.00 7.75 0.00
F2 SW APARTMENT 0.75 0.00 0.75 0.00
F2 NW APARTMENT 3.25 3.00 3.25 3.00
F2 SE APARTMENT 2.00 0.00 2.00 0.00
F2 NE APARTMENT 3.75 0.00 3.75 0.00
F2 N1 APARTMENT 5.25 2.50 5.25 2.50
F2 N2 APARTMENT 6.00 2.50 6.00 2.50
F2 S1 APARTMENT 2.00 0.00 2.00 0.00
F2 S2 APARTMENT 2.25 0.00 2.25 0.00
F3 SW APARTMENT 1.25 0.00 1.25 0.00
F3 NW APARTMENT 1.75 3.00 1.75 3.00
F3 SE APARTMENT 1.25 0.00 1.25 0.00
F3 NE APARTMENT 2.00 0.00 2.00 0.00
F3 N1 APARTMENT 5.25 2.50 5.25 2.50
F3 N2 APARTMENT 5.25 2.75 5.25 2.75
F3 S1 APARTMENT 4.75 0.00 4.75 0.00
F3 S2 APARTMENT 5.25 0.00 5.25 0.00
F4 SW APARTMENT 1.25 0.00 1.25 0.00
F4 NW APARTMENT 1.25 3.00 1.25 3.00
F4 SE APARTMENT 3.25 0.00 3.25 0.00
F4 NE APARTMENT 2.50 0.00 2.50 0.00
F4 N1 APARTMENT 5.75 2.75 5.75 2.75
F4 N2 APARTMENT 7.25 2.75 7.25 2.75
F4 S1 APARTMENT 2.25 0.00 2.25 0.00
F4 S2 APARTMENT 2.50 0.00 2.50 0.00
M SW APARTMENT 1.00 0.00 1.00 0.00
M NW APARTMENT 2.00 3.00 2.00 3.00
M SE APARTMENT 1.75 0.00 1.75 0.00
M NE APARTMENT 2.75 0.00 2.75 0.00
M N1 APARTMENT 6.25 2.75 6.25 2.75
M N2 APARTMENT 7.00 2.75 7.00 2.75
M S1 APARTMENT 4.25 0.00 4.25 0.00
M S2 APARTMENT 3.75 0.00 3.75 0.00
F6 SW APARTMENT 1.00 0.00 1.00 0.00
F6 NW APARTMENT 1.50 2.75 1.50 2.75
F6 SE APARTMENT 1.75 0.00 1.75 0.00
F6 NE APARTMENT 4.00 0.00 4.00 0.00
F6 N1 APARTMENT 4.25 2.75 4.25 2.75
F6 N2 APARTMENT 5.50 2.75 5.50 2.75
F6 S1 APARTMENT 3.75 0.00 3.75 0.00
F6 S2 APARTMENT 4.25 0.00 4.25 0.00
F7 SW APARTMENT 2.00 0.00 2.00 0.00
F7 NW APARTMENT 2.25 2.50 2.25 2.50
F7 SE APARTMENT 2.50 0.00 2.50 0.00
F7 NE APARTMENT 6.75 0.00 6.75 0.00
F7 N1 APARTMENT 4.00 2.75 4.00 2.75
F7 N2 APARTMENT 5.00 2.75 5.00 2.75
F7 S1 APARTMENT 3.50 0.00 3.50 0.00
F7 S2 APARTMENT 4.75 0.00 4.75 0.00
F8 SW APARTMENT 1.50 0.00 1.50 0.00
F8 NW APARTMENT 0.75 2.25 0.75 2.25
F8 SE APARTMENT 1.00 0.00 1.00 0.00
F8 NE APARTMENT 1.50 0.00 1.50 0.00
F8 N1 APARTMENT 5.50 2.75 5.50 2.75
F8 N2 APARTMENT 6.25 2.75 6.25 2.75
F8 S1 APARTMENT 2.75 0.00 2.75 0.00
F8 S2 APARTMENT 3.25 0.00 3.25 0.00
F9 SW APARTMENT 1.00 0.00 1.00 0.00
F9 NW APARTMENT 1.75 2.25 1.75 2.25
F9 SE APARTMENT 0.75 0.00 0.75 0.00
F9 NE APARTMENT 2.25 0.00 2.25 0.00
F9 N1 APARTMENT 7.75 2.50 7.75 2.50
F9 N2 APARTMENT 8.75 2.75 8.75 2.75
F9 S1 APARTMENT 2.50 0.00 2.50 0.00
F9 S2 APARTMENT 3.25 0.00 3.25 0.00
T SW APARTMENT 0.25 0.00 0.25 0.00
T NW APARTMENT 0.00 4.50 0.00 4.50
T SE APARTMENT 0.25 0.00 0.25 0.00
T NE APARTMENT 0.25 0.25 0.25 0.25
T N1 APARTMENT 6.75 4.25 6.75 4.25
T N2 APARTMENT 7.50 3.75 7.50 3.75
T S1 APARTMENT 1.25 0.00 1.25 0.00
T S2 APARTMENT 1.50 0.00 1.50 0.00
G CORRIDOR 0.00 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
Facility 202.50 6.25 200.25 6.25
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:21

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.354 0.151 0.000 0.278
G NW APARTMENT 1.71 2.50 268.96 0.353 0.151 0.000 0.263
OFFICE 0.94 1.00 268.96 0.519 0.175 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.353 0.151 0.000 0.263
G N1 APARTMENT 1.71 2.50 268.96 0.353 0.091 0.000 0.253
G N2 APARTMENT 1.71 2.50 268.97 0.353 0.091 0.000 0.253
G S1 APARTMENT 1.71 2.50 268.96 0.354 0.091 0.000 0.274
G S2 APARTMENT 1.71 2.50 268.97 0.354 0.091 0.000 0.275
F2 SW APARTMENT 1.71 2.50 268.96 0.354 0.218 0.000 0.307
F2 NW APARTMENT 1.71 2.50 268.96 0.354 0.217 0.000 0.292
F2 SE APARTMENT 1.71 2.50 268.96 0.354 0.218 0.000 0.310
F2 NE APARTMENT 1.71 2.50 268.96 0.353 0.217 0.000 0.291
F2 N1 APARTMENT 1.71 2.50 268.96 0.353 0.131 0.000 0.283
F2 N2 APARTMENT 1.71 2.50 268.97 0.353 0.131 0.000 0.283
F2 S1 APARTMENT 1.71 2.50 268.96 0.354 0.131 0.000 0.305
F2 S2 APARTMENT 1.71 2.50 268.97 0.354 0.131 0.000 0.305
F3 SW APARTMENT 1.71 2.50 268.96 0.354 0.258 0.000 0.324
F3 NW APARTMENT 1.71 2.50 268.96 0.354 0.257 0.000 0.306
F3 SE APARTMENT 1.71 2.50 268.96 0.354 0.258 0.000 0.324
F3 NE APARTMENT 1.71 2.50 268.96 0.353 0.257 0.000 0.306
F3 N1 APARTMENT 1.71 2.50 268.96 0.354 0.155 0.000 0.299
F3 N2 APARTMENT 1.71 2.50 268.97 0.354 0.155 0.000 0.299
F3 S1 APARTMENT 1.71 2.50 268.96 0.354 0.155 0.000 0.322
F3 S2 APARTMENT 1.71 2.50 268.97 0.354 0.155 0.000 0.322
F4 SW APARTMENT 1.71 2.50 268.96 0.354 0.288 0.000 0.316
F4 NW APARTMENT 1.71 2.50 268.96 0.353 0.288 0.000 0.298
F4 SE APARTMENT 1.71 2.50 268.96 0.354 0.288 0.000 0.317
F4 NE APARTMENT 1.71 2.50 268.96 0.353 0.288 0.000 0.298
F4 N1 APARTMENT 1.71 2.50 268.96 0.354 0.173 0.000 0.292
F4 N2 APARTMENT 1.71 2.50 268.97 0.354 0.173 0.000 0.292
F4 S1 APARTMENT 1.71 2.50 268.96 0.354 0.174 0.000 0.315
F4 S2 APARTMENT 1.71 2.50 268.97 0.354 0.174 0.000 0.315
M SW APARTMENT 1.71 2.50 268.96 0.354 0.313 0.000 0.327
M NW APARTMENT 1.71 2.50 268.96 0.353 0.312 0.000 0.307
M SE APARTMENT 1.71 2.50 268.96 0.354 0.313 0.000 0.327
M NE APARTMENT 1.71 2.50 268.96 0.353 0.312 0.000 0.307
M N1 APARTMENT 1.71 2.50 268.96 0.354 0.188 0.000 0.301
M N2 APARTMENT 1.71 2.50 268.97 0.354 0.188 0.000 0.301
M S1 APARTMENT 1.71 2.50 268.96 0.354 0.189 0.000 0.325
M S2 APARTMENT 1.71 2.50 268.97 0.354 0.189 0.000 0.325
F6 SW APARTMENT 1.71 2.50 268.96 0.354 0.334 0.000 0.335
F6 NW APARTMENT 1.71 2.50 268.96 0.353 0.334 0.000 0.314
F6 SE APARTMENT 1.71 2.50 268.96 0.354 0.334 0.000 0.336
F6 NE APARTMENT 1.71 2.50 268.96 0.353 0.334 0.000 0.314
F6 N1 APARTMENT 1.71 2.50 268.96 0.353 0.201 0.000 0.308
F6 N2 APARTMENT 1.71 2.50 268.97 0.353 0.201 0.000 0.308
F6 S1 APARTMENT 1.71 2.50 268.96 0.354 0.202 0.000 0.333
F6 S2 APARTMENT 1.71 2.50 268.97 0.354 0.202 0.000 0.333
F7 SW APARTMENT 1.71 2.50 268.96 0.354 0.353 0.000 0.342
F7 NW APARTMENT 1.71 2.50 268.96 0.353 0.353 0.000 0.319
F7 SE APARTMENT 1.71 2.50 268.96 0.354 0.353 0.000 0.342
F7 NE APARTMENT 1.71 2.50 268.96 0.353 0.353 0.000 0.319
F7 N1 APARTMENT 1.71 2.50 268.96 0.353 0.213 0.000 0.313
F7 N2 APARTMENT 1.71 2.50 268.97 0.353 0.213 0.000 0.313
F7 S1 APARTMENT 1.71 2.50 268.96 0.354 0.213 0.000 0.340
F7 S2 APARTMENT 1.71 2.50 268.97 0.354 0.213 0.000 0.340
F8 SW APARTMENT 1.71 2.50 268.96 0.354 0.370 0.000 0.350
F8 NW APARTMENT 1.71 2.50 268.96 0.353 0.370 0.000 0.326
F8 SE APARTMENT 1.71 2.50 268.96 0.354 0.370 0.000 0.350
F8 NE APARTMENT 1.71 2.50 268.96 0.353 0.370 0.000 0.325
F8 N1 APARTMENT 1.71 2.50 268.96 0.353 0.223 0.000 0.319
F8 N2 APARTMENT 1.71 2.50 268.97 0.353 0.223 0.000 0.319
F8 S1 APARTMENT 1.71 2.50 268.96 0.354 0.223 0.000 0.348
F8 S2 APARTMENT 1.71 2.50 268.97 0.354 0.223 0.000 0.348
F9 SW APARTMENT 1.71 2.50 268.96 0.354 0.386 0.000 0.355
F9 NW APARTMENT 1.71 2.50 268.96 0.353 0.385 0.000 0.330
F9 SE APARTMENT 1.71 2.50 268.96 0.354 0.386 0.000 0.356
F9 NE APARTMENT 1.71 2.50 268.96 0.353 0.385 0.000 0.330
F9 N1 APARTMENT 1.71 2.50 268.96 0.353 0.232 0.000 0.324
F9 N2 APARTMENT 1.71 2.50 268.97 0.353 0.232 0.000 0.324
F9 S1 APARTMENT 1.71 2.50 268.96 0.354 0.233 0.000 0.354
F9 S2 APARTMENT 1.71 2.50 268.97 0.354 0.233 0.000 0.354
T SW APARTMENT 1.71 2.50 268.96 0.353 0.400 0.000 0.358
T NW APARTMENT 1.71 2.50 268.96 0.353 0.400 0.000 0.334
T SE APARTMENT 1.71 2.50 268.96 0.353 0.400 0.000 0.359
T NE APARTMENT 1.71 2.50 268.96 0.353 0.400 0.000 0.334
T N1 APARTMENT 1.71 2.50 268.96 0.353 0.241 0.000 0.329
T N2 APARTMENT 1.71 2.50 268.97 0.353 0.241 0.000 0.329
T S1 APARTMENT 1.71 2.50 268.96 0.354 0.241 0.000 0.357
T S2 APARTMENT 1.71 2.50 268.97 0.354 0.241 0.000 0.357
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
OFFICE 0.94 1.00 268.96 0.502 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F2 SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F2 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F2 SE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F2 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F2 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F2 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F2 S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F2 S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F3 SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F3 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F3 SE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F3 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F3 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F3 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F3 S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F3 S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F4 SW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F4 NW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F4 SE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F4 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F4 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F4 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F4 S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F4 S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F6 SW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F6 NW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F6 SE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F6 NE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F6 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F6 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F6 S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F6 S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F7 SW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F7 NW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F7 SE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F7 NE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F7 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F7 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F7 S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F7 S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F8 SW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F8 NW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F8 SE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F8 NE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F8 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F8 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F8 S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F8 S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F9 SW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F9 NW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F9 SE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F9 NE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
F9 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F9 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F9 S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F9 S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.96 0.342 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:21

Surfaces by Class

Total Outdoors
Wall 420 140
Floor 90 9
Roof 90 9
Internal Mass 80 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 140 140
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 80
Conditioned Zones 80
Unconditioned Zones 10
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 4156
Defaulted Fields 814
Fields with Defaults 11184
Autosized Fields 1293
Autosizable Fields 1630
Autocalculated Fields 907
Autocalculatable Fields 1710



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2015-09-09 19:12:21

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 2555.34 52259.14 11-JUN-04:15 163265.22 16-DEC-17:15
Electricity:Building 1433.88 25760.85 01-JAN-03:15 70162.48 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity 296.56 6715.87 01-JAN-00:15 14401.37 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 242.55 5824.91 01-JAN-00:15 11484.27 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:OFFICE 39.38 663.42 01-JAN-00:15 2934.49 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 29.88 469.18 01-JAN-00:15 2345.88 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:G CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F2 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F2 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F3 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F3 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F4 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F4 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:M SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M CORRIDOR 32.88 1042.61 01-JAN-00:15 1042.61 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 32.88 1042.61 01-JAN-00:15 1042.61 01-JAN-00:15
Electricity:Zone:F6 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F6 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F7 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F7 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F8 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F8 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F9 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F9 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:T SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T CORRIDOR 179.47 1701.70 01-JAN-00:15 10868.20 01-JAN-07:15
InteriorLights:Electricity:Zone:T CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 54.01 890.97 01-JAN-00:15 2917.11 01-JAN-19:15
InteriorEquipment:Electricity 1137.32 19044.98 01-JAN-03:15 57142.09 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 1137.32 19044.98 01-JAN-03:15 57142.09 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 9.50 194.24 01-JAN-00:15 588.62 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T CORRIDOR 163.03 1180.40 01-JAN-00:15 10346.90 01-JAN-07:15
Fans:Electricity 553.30 17544.92 06-JAN-08:45 17544.92 01-JAN-00:15
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Electricity:HVAC 902.47 18206.16 29-MAY-02:15 90189.44 16-DEC-17:00
ElectricityProduced:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityProduced:HVAC 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricityProduced 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 2555.34 52259.14 11-JUN-04:15 163265.22 16-DEC-17:15
ElectricityPurchased:Plant 2555.34 52259.14 11-JUN-04:15 163265.22 16-DEC-17:15
Cogeneration:ElectricityPurchased 2555.34 52259.14 11-JUN-04:15 163265.22 16-DEC-17:15
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 2555.34 52259.14 11-JUN-04:15 163265.22 16-DEC-17:15
ElectricityNet:Plant 2555.34 52259.14 11-JUN-04:15 163265.22 16-DEC-17:15
Cogeneration:ElectricityNet 2555.34 52259.14 11-JUN-04:15 163265.22 16-DEC-17:15
ExteriorLights:Electricity 162.51 0.00 01-JAN-08:15 10364.00 01-JAN-00:15
General:ExteriorLights:Electricity 162.51 0.00 01-JAN-08:15 10364.00 01-JAN-00:15
General:Fans:Electricity 553.30 17544.92 06-JAN-08:45 17544.92 01-JAN-00:15
Cooling:Electricity 99.13 0.00 01-JAN-00:15 54119.07 11-JUL-17:00
Heating:Electricity 213.87 0.00 25-MAR-16:30 71247.61 16-DEC-17:00
Electricity:Plant 56.47 36.93 03-MAY-06:00 3638.53 12-JUL-15:00
HeatRejection:Electricity 4.24 0.00 01-JAN-00:15 1961.30 12-JUL-15:00
Boiler Parasitic:Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Pumps:Electricity 52.23 36.93 03-MAY-06:00 1677.22 01-JAN-00:15
WIRED_LTG_ELECTRICITY 0.44 0.00 01-JAN-00:15 21.60 01-JAN-19:30
WIRED_INT_EQUIP 979.40 1018.50 01-JAN-00:15 10185.00 01-JAN-07:15


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 1951.51 2357.00 22-FEB-23:45 258166.95 16-DEC-19:00
Gas:Plant 1951.51 2357.00 22-FEB-23:45 258166.95 16-DEC-19:00
WaterSystems:Gas 1178.71 2357.00 01-JAN-00:15 80844.40 14-FEB-07:45
Water Heater:WaterSystems:Gas 1178.71 2357.00 01-JAN-00:15 80844.40 14-FEB-07:45
Heating:Gas 772.80 0.00 06-FEB-16:15 194476.20 16-DEC-17:00
Boiler:Heating:Gas 772.80 0.00 06-FEB-16:15 194476.20 16-DEC-17:00


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
PlantLoopCoolingDemand:Facility 389.82 0.00 01-JAN-00:15 243466.96 11-JUL-17:00
PlantLoopCoolingDemand:HVAC 389.82 0.00 01-JAN-00:15 243466.96 11-JUL-17:00
CoolingCoils:PlantLoopCoolingDemand 389.82 0.00 01-JAN-00:15 243466.96 11-JUL-17:00


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 5091.84 0.00 01-JAN-02:15 0.00 11-JUL-17:15
Water:Plant 5091.84 0.00 01-JAN-02:15 0.00 11-JUL-17:15
WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
MainsWater:Facility 5091.84 0.00 01-JAN-02:15 0.00 11-JUL-17:15
MainsWater:Plant 5091.84 0.00 01-JAN-02:15 0.00 11-JUL-17:15
WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
sub cat:WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
sub cat:WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
HeatRejection:Water 313.33 0.00 01-JAN-00:15 0.00 11-JUL-17:00
HeatRejection:MainsWater 313.33 0.00 01-JAN-00:15 0.00 11-JUL-17:00


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 1538.31 505.43 11-AUG-01:15 189396.87 16-DEC-19:00
PlantLoopHeatingDemand:Plant 917.61 505.43 11-AUG-01:15 59373.88 16-FEB-07:30
WaterSystems:PlantLoopHeatingDemand 917.61 505.43 11-AUG-01:15 59373.88 16-FEB-07:30
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 3559.45 5743.68 04-SEP-03:00 577948.63 16-DEC-17:00
EnergyTransfer:Building 950.36 3799.20 02-SEP-11:15 191361.77 03-DEC-02:00
EnergyTransfer:Zone:G SW APARTMENT 11.28 0.00 09-MAR-20:45 2311.72 13-SEP-15:15
Heating:EnergyTransfer 503.40 0.00 11-MAR-12:30 191361.77 03-DEC-02:00
Heating:EnergyTransfer:Zone:G SW APARTMENT 7.01 0.00 01-JAN-10:30 1864.49 16-DEC-17:00
Cooling:EnergyTransfer 446.96 0.00 02-JAN-19:45 143019.27 11-JUL-16:30
Cooling:EnergyTransfer:Zone:G SW APARTMENT 4.27 0.00 01-JAN-00:15 2311.72 13-SEP-15:15
EnergyTransfer:Zone:G NW APARTMENT 11.40 0.03 12-AUG-09:00 1862.78 16-DEC-17:00
Heating:EnergyTransfer:Zone:G NW APARTMENT 8.88 0.00 06-FEB-14:45 1862.78 16-DEC-17:00
Cooling:EnergyTransfer:Zone:G NW APARTMENT 2.52 0.00 01-JAN-00:15 1787.49 15-JUL-18:00
EnergyTransfer:Zone:OFFICE 17.79 0.06 03-DEC-14:00 3592.82 13-SEP-13:15
Heating:EnergyTransfer:Zone:OFFICE 4.79 0.00 01-JAN-10:15 2022.53 16-DEC-19:00
Cooling:EnergyTransfer:Zone:OFFICE 13.00 0.00 01-JAN-00:15 3592.82 13-SEP-13:15
EnergyTransfer:Zone:G NE APARTMENT 11.46 0.00 05-JUN-17:00 1867.25 16-DEC-17:00
Heating:EnergyTransfer:Zone:G NE APARTMENT 8.93 0.00 05-FEB-09:30 1867.25 16-DEC-17:00
Cooling:EnergyTransfer:Zone:G NE APARTMENT 2.54 0.00 01-JAN-00:15 1101.32 11-JUL-16:45
EnergyTransfer:Zone:G N1 APARTMENT 7.37 0.07 28-MAY-14:00 1102.99 16-DEC-16:00
Heating:EnergyTransfer:Zone:G N1 APARTMENT 4.39 0.00 21-JAN-17:15 1102.99 16-DEC-16:00
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 2.97 0.00 01-JAN-00:15 732.84 03-JUL-19:00
EnergyTransfer:Zone:G N2 APARTMENT 7.36 0.01 22-OCT-10:45 1102.99 16-DEC-16:00
Heating:EnergyTransfer:Zone:G N2 APARTMENT 4.40 0.00 21-JAN-17:15 1102.99 16-DEC-16:00
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 2.95 0.00 01-JAN-00:15 732.57 03-JUL-19:00
EnergyTransfer:Zone:G S1 APARTMENT 7.19 0.00 18-JUL-20:45 1642.17 13-SEP-13:45
Heating:EnergyTransfer:Zone:G S1 APARTMENT 2.71 0.00 01-JAN-10:00 1097.52 16-DEC-16:00
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 4.48 0.00 01-JAN-00:15 1642.17 13-SEP-13:45
EnergyTransfer:Zone:G S2 APARTMENT 7.15 0.03 18-JUN-15:30 1699.92 13-SEP-13:45
Heating:EnergyTransfer:Zone:G S2 APARTMENT 2.55 0.00 01-JAN-09:30 1088.60 16-DEC-16:00
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 4.61 0.00 01-JAN-00:15 1699.92 13-SEP-13:45
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F2 SW APARTMENT 13.61 0.07 19-JUL-05:45 2998.27 13-SEP-15:15
Heating:EnergyTransfer:Zone:F2 SW APARTMENT 5.81 0.00 01-JAN-09:15 2279.17 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT 7.80 0.00 01-JAN-00:15 2998.27 13-SEP-15:15
EnergyTransfer:Zone:F2 NW APARTMENT 11.76 0.05 15-OCT-24:00 2385.29 15-JUL-18:00
Heating:EnergyTransfer:Zone:F2 NW APARTMENT 7.93 0.00 06-JAN-15:00 2300.59 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT 3.84 0.00 01-JAN-00:15 2385.29 15-JUL-18:00
EnergyTransfer:Zone:F2 SE APARTMENT 13.36 0.01 01-SEP-22:45 2768.11 13-SEP-13:30
Heating:EnergyTransfer:Zone:F2 SE APARTMENT 5.09 0.00 01-JAN-09:00 2240.85 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT 8.27 0.00 01-JAN-00:15 2768.11 13-SEP-13:30
EnergyTransfer:Zone:F2 NE APARTMENT 11.49 0.00 30-APR-13:30 2290.12 03-DEC-02:00
Heating:EnergyTransfer:Zone:F2 NE APARTMENT 7.92 0.00 21-JAN-17:15 2290.12 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT 3.57 0.00 01-JAN-00:15 1590.87 11-JUL-16:30
EnergyTransfer:Zone:F2 N1 APARTMENT 6.90 0.01 05-JAN-19:00 1245.23 03-DEC-02:00
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT 2.72 0.00 01-JAN-11:00 1245.23 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT 4.18 0.00 01-JAN-00:15 1056.78 16-JUL-18:15
EnergyTransfer:Zone:F2 N2 APARTMENT 6.91 0.00 03-NOV-02:00 1244.70 03-DEC-02:00
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT 2.73 0.00 01-JAN-11:00 1244.70 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT 4.18 0.00 01-JAN-00:15 1038.79 03-JUL-19:00
EnergyTransfer:Zone:F2 S1 APARTMENT 9.40 0.03 03-AUG-11:45 2219.02 13-SEP-13:45
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT 1.69 0.00 01-JAN-00:15 1224.45 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT 7.71 0.00 01-JAN-05:15 2219.02 13-SEP-13:45
EnergyTransfer:Zone:F2 S2 APARTMENT 9.46 0.05 14-MAR-14:15 2239.43 13-SEP-13:45
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT 1.66 0.00 01-JAN-00:15 1221.53 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT 7.80 0.00 02-JAN-10:00 2239.43 13-SEP-13:45
EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F3 SW APARTMENT 14.32 0.01 15-JUN-22:00 3015.34 13-SEP-15:15
Heating:EnergyTransfer:Zone:F3 SW APARTMENT 5.88 0.00 01-JAN-00:30 2570.45 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT 8.43 0.00 01-JAN-00:15 3015.34 13-SEP-15:15
EnergyTransfer:Zone:F3 NW APARTMENT 12.24 0.00 04-SEP-00:45 2591.93 03-DEC-02:00
Heating:EnergyTransfer:Zone:F3 NW APARTMENT 8.02 0.00 01-JAN-17:15 2591.93 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT 4.22 0.00 01-JAN-00:15 2428.49 15-JUL-18:00
EnergyTransfer:Zone:F3 SE APARTMENT 13.79 0.00 02-JAN-00:30 2652.85 13-SEP-13:30
Heating:EnergyTransfer:Zone:F3 SE APARTMENT 5.76 0.00 01-JAN-00:30 2553.43 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT 8.02 0.00 01-JAN-00:15 2652.85 13-SEP-13:30
EnergyTransfer:Zone:F3 NE APARTMENT 11.93 0.02 09-SEP-11:15 2581.06 03-DEC-02:00
Heating:EnergyTransfer:Zone:F3 NE APARTMENT 8.02 0.00 01-JAN-18:15 2581.06 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT 3.90 0.00 01-JAN-00:15 1635.87 11-JUL-16:15
EnergyTransfer:Zone:F3 N1 APARTMENT 7.22 0.10 22-AUG-14:30 1398.14 03-DEC-02:00
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT 2.60 0.00 01-JAN-06:45 1398.14 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT 4.62 0.00 01-JAN-00:15 1109.65 16-JUL-18:15
EnergyTransfer:Zone:F3 N2 APARTMENT 7.22 0.05 05-FEB-04:30 1397.60 03-DEC-02:00
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT 2.61 0.00 01-JAN-06:45 1397.60 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT 4.61 0.00 01-JAN-00:15 1089.98 03-JUL-19:00
EnergyTransfer:Zone:F3 S1 APARTMENT 10.34 0.01 13-JUL-08:30 2257.93 13-SEP-13:45
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT 1.61 0.00 01-JAN-00:15 1375.40 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT 8.72 0.00 02-JAN-10:45 2257.93 13-SEP-13:45
EnergyTransfer:Zone:F3 S2 APARTMENT 10.34 0.03 02-AUG-09:15 2269.02 13-SEP-13:45
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT 1.61 0.00 01-JAN-00:15 1374.16 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT 8.73 0.00 02-JAN-10:45 2269.02 13-SEP-13:45
EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F4 SW APARTMENT 14.80 0.01 15-JUN-22:00 3019.25 11-JUL-17:15
Heating:EnergyTransfer:Zone:F4 SW APARTMENT 6.28 0.00 01-JAN-00:15 2819.29 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT 8.52 0.00 01-JAN-03:15 3019.25 11-JUL-17:15
EnergyTransfer:Zone:F4 NW APARTMENT 12.80 0.01 06-JUN-14:15 2841.33 03-DEC-02:00
Heating:EnergyTransfer:Zone:F4 NW APARTMENT 8.49 0.00 01-JAN-17:15 2841.33 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT 4.31 0.00 01-JAN-00:15 2437.41 15-JUL-18:00
EnergyTransfer:Zone:F4 SE APARTMENT 14.23 0.04 07-SEP-16:00 2807.06 03-DEC-02:00
Heating:EnergyTransfer:Zone:F4 SE APARTMENT 6.28 0.00 01-JAN-00:15 2807.06 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT 7.95 0.00 01-JAN-00:30 2629.50 13-SEP-13:30
EnergyTransfer:Zone:F4 NE APARTMENT 12.47 0.00 16-JUN-13:45 2830.27 03-DEC-02:00
Heating:EnergyTransfer:Zone:F4 NE APARTMENT 8.49 0.00 01-JAN-11:00 2830.27 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT 3.99 0.00 01-JAN-00:15 1639.80 11-JUL-16:15
EnergyTransfer:Zone:F4 N1 APARTMENT 7.54 0.04 22-OCT-11:00 1541.22 03-DEC-02:00
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT 2.78 0.00 01-JAN-01:00 1541.22 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT 4.76 0.00 01-JAN-00:15 1123.55 16-JUL-18:15
EnergyTransfer:Zone:F4 N2 APARTMENT 7.54 0.01 17-APR-05:15 1540.67 03-DEC-02:00
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT 2.79 0.00 01-JAN-01:00 1540.67 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT 4.75 0.00 01-JAN-00:15 1101.67 15-JUL-18:00
EnergyTransfer:Zone:F4 S1 APARTMENT 10.76 0.00 05-JUN-12:15 2255.75 13-SEP-13:45
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT 1.74 0.00 01-JAN-00:15 1517.74 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT 9.01 0.00 02-JAN-12:30 2255.75 13-SEP-13:45
EnergyTransfer:Zone:F4 S2 APARTMENT 10.74 0.06 23-SEP-16:00 2265.34 13-SEP-13:45
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT 1.75 0.00 01-JAN-00:15 1517.05 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT 8.99 0.00 02-JAN-12:30 2265.34 13-SEP-13:45
EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M SW APARTMENT 14.99 0.03 18-APR-22:15 3044.14 11-JUL-17:15
Heating:EnergyTransfer:Zone:M SW APARTMENT 6.60 0.00 01-JAN-00:15 3015.86 03-DEC-02:00
Cooling:EnergyTransfer:Zone:M SW APARTMENT 8.39 0.00 01-JAN-03:45 3044.14 11-JUL-17:15
EnergyTransfer:Zone:M NW APARTMENT 13.10 0.04 29-OCT-14:30 3037.25 03-DEC-02:00
Heating:EnergyTransfer:Zone:M NW APARTMENT 8.82 0.00 01-JAN-17:15 3037.25 03-DEC-02:00
Cooling:EnergyTransfer:Zone:M NW APARTMENT 4.28 0.00 01-JAN-00:15 2463.15 15-JUL-18:00
EnergyTransfer:Zone:M SE APARTMENT 14.41 0.05 21-JAN-14:30 3004.55 03-DEC-02:00
Heating:EnergyTransfer:Zone:M SE APARTMENT 6.61 0.00 01-JAN-00:15 3004.55 03-DEC-02:00
Cooling:EnergyTransfer:Zone:M SE APARTMENT 7.80 0.00 01-JAN-03:45 2645.26 11-JUL-13:00
EnergyTransfer:Zone:M NE APARTMENT 12.77 0.01 30-AUG-10:45 3026.11 03-DEC-02:00
Heating:EnergyTransfer:Zone:M NE APARTMENT 8.81 0.00 01-JAN-10:45 3026.11 03-DEC-02:00
Cooling:EnergyTransfer:Zone:M NE APARTMENT 3.96 0.00 01-JAN-00:15 1659.98 11-JUL-16:15
EnergyTransfer:Zone:M N1 APARTMENT 7.71 0.04 28-AUG-15:00 1652.09 03-DEC-02:00
Heating:EnergyTransfer:Zone:M N1 APARTMENT 2.89 0.00 01-JAN-01:45 1652.09 03-DEC-02:00
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 4.82 0.00 01-JAN-00:15 1151.37 16-JUL-18:15
EnergyTransfer:Zone:M N2 APARTMENT 7.71 0.10 02-APR-01:30 1651.55 03-DEC-02:00
Heating:EnergyTransfer:Zone:M N2 APARTMENT 2.90 0.00 01-JAN-01:45 1651.55 03-DEC-02:00
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 4.81 0.00 01-JAN-00:15 1126.68 16-JUL-18:15
EnergyTransfer:Zone:M S1 APARTMENT 10.89 0.00 12-AUG-09:45 2262.60 13-SEP-13:45
Heating:EnergyTransfer:Zone:M S1 APARTMENT 1.85 0.00 01-JAN-00:15 1629.61 03-DEC-02:00
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 9.03 0.00 02-JAN-12:45 2262.60 13-SEP-13:45
EnergyTransfer:Zone:M S2 APARTMENT 10.86 0.00 11-SEP-20:00 2271.94 13-SEP-13:45
Heating:EnergyTransfer:Zone:M S2 APARTMENT 1.86 0.00 01-JAN-00:15 1629.14 03-DEC-02:00
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 9.00 0.00 02-JAN-12:45 2271.94 13-SEP-13:45
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F6 SW APARTMENT 15.00 0.00 20-SEP-01:15 3232.72 03-DEC-02:00
Heating:EnergyTransfer:Zone:F6 SW APARTMENT 7.37 0.00 01-JAN-00:30 3232.72 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT 7.63 0.00 01-JAN-00:15 3006.08 11-JUL-17:15
EnergyTransfer:Zone:F6 NW APARTMENT 13.62 0.00 21-AUG-23:30 3254.93 03-DEC-02:00
Heating:EnergyTransfer:Zone:F6 NW APARTMENT 9.77 0.00 01-JAN-17:15 3254.93 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT 3.85 0.00 01-JAN-00:15 2422.35 15-JUL-18:00
EnergyTransfer:Zone:F6 SE APARTMENT 14.44 0.01 14-OCT-20:45 3221.42 03-DEC-02:00
Heating:EnergyTransfer:Zone:F6 SE APARTMENT 7.39 0.00 01-JAN-00:30 3221.42 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT 7.05 0.00 01-JAN-00:15 2607.86 11-JUL-13:00
EnergyTransfer:Zone:F6 NE APARTMENT 13.33 0.01 18-AUG-08:00 3243.69 03-DEC-02:00
Heating:EnergyTransfer:Zone:F6 NE APARTMENT 9.76 0.00 01-JAN-11:00 3243.69 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT 3.57 0.00 01-JAN-00:15 1618.86 11-JUL-16:15
EnergyTransfer:Zone:F6 N1 APARTMENT 7.83 0.02 20-OCT-02:30 1918.95 01-SEP-13:00
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT 3.41 0.00 01-JAN-01:00 1918.95 01-SEP-13:00
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT 4.42 0.00 01-JAN-00:15 1118.18 16-JUL-18:15
EnergyTransfer:Zone:F6 N2 APARTMENT 7.84 0.02 10-MAR-24:00 1946.08 01-SEP-13:00
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT 3.43 0.00 01-JAN-01:00 1946.08 01-SEP-13:00
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT 4.41 0.00 01-JAN-00:15 1093.61 16-JUL-18:15
EnergyTransfer:Zone:F6 S1 APARTMENT 10.49 0.01 23-SEP-15:45 2205.81 13-SEP-13:45
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT 2.21 0.00 01-JAN-00:15 1767.29 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT 8.29 0.00 02-JAN-10:30 2205.81 13-SEP-13:45
EnergyTransfer:Zone:F6 S2 APARTMENT 10.47 0.05 13-JUL-08:30 2215.16 13-SEP-13:45
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT 2.21 0.00 01-JAN-00:15 1766.75 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT 8.25 0.00 02-JAN-10:30 2215.16 13-SEP-13:45
EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F7 SW APARTMENT 15.09 0.05 14-JUN-08:30 3413.54 03-DEC-02:00
Heating:EnergyTransfer:Zone:F7 SW APARTMENT 7.98 0.00 01-JAN-00:45 3413.54 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT 7.11 0.00 01-JAN-00:15 2988.40 11-JUL-17:15
EnergyTransfer:Zone:F7 NW APARTMENT 14.05 0.05 06-JUN-14:30 3435.53 03-DEC-02:00
Heating:EnergyTransfer:Zone:F7 NW APARTMENT 10.49 0.00 01-JAN-17:15 3435.53 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT 3.56 0.00 01-JAN-00:15 2405.14 15-JUL-18:00
EnergyTransfer:Zone:F7 SE APARTMENT 14.55 0.02 03-SEP-08:30 3402.20 03-DEC-02:00
Heating:EnergyTransfer:Zone:F7 SE APARTMENT 8.00 0.00 01-JAN-00:45 3402.20 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT 6.55 0.00 01-JAN-00:15 2590.32 11-JUL-13:00
EnergyTransfer:Zone:F7 NE APARTMENT 13.80 0.02 06-SEP-12:45 3424.27 03-DEC-02:00
Heating:EnergyTransfer:Zone:F7 NE APARTMENT 10.48 0.00 01-JAN-17:30 3424.27 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT 3.32 0.00 01-JAN-00:15 1599.99 11-JUL-16:15
EnergyTransfer:Zone:F7 N1 APARTMENT 7.97 0.04 29-OCT-21:00 2204.03 01-SEP-13:00
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT 3.81 0.00 01-JAN-01:00 2204.03 01-SEP-13:00
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT 4.16 0.00 01-JAN-00:15 1105.72 16-JUL-18:15
EnergyTransfer:Zone:F7 N2 APARTMENT 7.97 0.01 17-AUG-13:45 2230.29 01-SEP-13:00
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT 3.82 0.00 01-JAN-01:00 2230.29 01-SEP-13:00
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT 4.15 0.00 01-JAN-00:15 1081.58 16-JUL-18:15
EnergyTransfer:Zone:F7 S1 APARTMENT 10.26 0.03 29-AUG-10:00 2169.56 13-SEP-13:45
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT 2.50 0.00 01-JAN-00:15 1880.57 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT 7.77 0.00 02-JAN-10:30 2169.56 13-SEP-13:45
EnergyTransfer:Zone:F7 S2 APARTMENT 10.24 0.01 05-JUL-10:15 2178.93 13-SEP-13:45
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT 2.50 0.00 01-JAN-00:15 1879.99 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT 7.74 0.00 02-JAN-10:30 2178.93 13-SEP-13:45
EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F8 SW APARTMENT 15.24 0.01 27-FEB-11:15 3578.54 03-DEC-02:00
Heating:EnergyTransfer:Zone:F8 SW APARTMENT 8.59 0.00 01-JAN-00:45 3578.54 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT 6.65 0.00 01-JAN-00:15 2979.67 11-JUL-17:15
EnergyTransfer:Zone:F8 NW APARTMENT 14.50 0.02 31-JUL-20:30 3600.24 03-DEC-02:00
Heating:EnergyTransfer:Zone:F8 NW APARTMENT 11.18 0.00 01-JAN-17:15 3600.24 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT 3.32 0.00 01-JAN-00:15 2397.72 15-JUL-18:00
EnergyTransfer:Zone:F8 SE APARTMENT 14.73 0.00 03-SEP-01:00 3567.15 03-DEC-02:00
Heating:EnergyTransfer:Zone:F8 SE APARTMENT 8.61 0.00 01-JAN-01:15 3567.15 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT 6.11 0.00 01-JAN-00:15 2580.56 11-JUL-13:00
EnergyTransfer:Zone:F8 NE APARTMENT 14.29 0.00 29-AUG-17:00 3588.93 03-DEC-02:00
Heating:EnergyTransfer:Zone:F8 NE APARTMENT 11.18 0.00 29-JAN-17:15 3588.93 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT 3.11 0.00 01-JAN-00:15 1591.56 11-JUL-16:15
EnergyTransfer:Zone:F8 N1 APARTMENT 8.17 0.03 13-AUG-12:00 2447.13 01-SEP-13:00
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT 4.23 0.00 01-JAN-07:45 2447.13 01-SEP-13:00
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT 3.95 0.00 01-JAN-00:15 1104.06 16-JUL-18:00
EnergyTransfer:Zone:F8 N2 APARTMENT 8.18 0.02 28-AUG-14:30 2469.70 01-SEP-13:00
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT 4.24 0.00 01-JAN-07:30 2469.70 01-SEP-13:00
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT 3.94 0.00 01-JAN-00:15 1080.13 16-JUL-18:00
EnergyTransfer:Zone:F8 S1 APARTMENT 10.10 0.01 15-OCT-11:15 2138.24 13-SEP-13:45
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT 2.80 0.00 01-JAN-00:15 1984.92 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT 7.30 0.00 02-JAN-10:15 2138.24 13-SEP-13:45
EnergyTransfer:Zone:F8 S2 APARTMENT 10.08 0.07 20-JAN-18:30 2147.71 13-SEP-13:45
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT 2.81 0.00 01-JAN-00:15 1984.33 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT 7.27 0.00 02-JAN-10:15 2147.71 13-SEP-13:45
EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F9 SW APARTMENT 15.93 0.03 06-NOV-17:15 3777.48 03-DEC-02:00
Heating:EnergyTransfer:Zone:F9 SW APARTMENT 9.80 0.00 01-JAN-01:00 3777.48 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT 6.14 0.00 01-JAN-00:15 3045.29 11-JUL-17:15
EnergyTransfer:Zone:F9 NW APARTMENT 15.65 0.00 03-SEP-22:30 3797.73 03-DEC-02:00
Heating:EnergyTransfer:Zone:F9 NW APARTMENT 12.54 0.00 06-JAN-15:00 3797.73 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT 3.11 0.00 01-JAN-00:15 2436.57 15-JUL-18:00
EnergyTransfer:Zone:F9 SE APARTMENT 15.40 0.03 17-AUG-00:15 3766.07 03-DEC-02:00
Heating:EnergyTransfer:Zone:F9 SE APARTMENT 9.80 0.00 01-JAN-01:00 3766.07 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT 5.60 0.00 01-JAN-00:15 2600.50 11-JUL-13:00
EnergyTransfer:Zone:F9 NE APARTMENT 15.46 0.01 23-MAR-11:30 3786.42 03-DEC-02:00
Heating:EnergyTransfer:Zone:F9 NE APARTMENT 12.51 0.00 31-JAN-21:00 3786.42 03-DEC-02:00
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT 2.95 0.00 01-JAN-00:15 1624.59 11-JUL-19:00
EnergyTransfer:Zone:F9 N1 APARTMENT 8.77 0.03 16-MAY-01:45 2706.55 01-SEP-13:00
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT 5.15 0.00 01-JAN-11:30 2706.55 01-SEP-13:00
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT 3.62 0.00 01-JAN-00:15 1141.92 16-JUL-18:00
EnergyTransfer:Zone:F9 N2 APARTMENT 8.78 0.03 25-AUG-12:30 2725.73 01-SEP-13:00
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT 5.17 0.00 01-JAN-11:00 2725.73 01-SEP-13:00
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT 3.61 0.00 01-JAN-00:15 1129.08 16-JUL-18:00
EnergyTransfer:Zone:F9 S1 APARTMENT 10.12 0.11 23-MAY-17:00 2202.31 15-MAY-15:15
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT 3.48 0.00 01-JAN-00:15 2202.31 15-MAY-15:15
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT 6.64 0.00 01-JAN-05:30 2118.69 13-SEP-14:15
EnergyTransfer:Zone:F9 S2 APARTMENT 10.10 0.21 13-MAR-08:30 2204.30 15-MAY-15:15
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT 3.49 0.00 01-JAN-00:15 2204.30 15-MAY-15:15
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT 6.61 0.00 01-JAN-05:30 2126.06 13-SEP-14:15
EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:T SW APARTMENT 21.50 0.02 08-APR-18:45 4190.49 03-DEC-02:00
Heating:EnergyTransfer:Zone:T SW APARTMENT 15.16 0.00 01-JAN-10:15 4190.49 03-DEC-02:00
Cooling:EnergyTransfer:Zone:T SW APARTMENT 6.34 0.00 01-JAN-00:15 3680.85 11-JUL-17:00
EnergyTransfer:Zone:T NW APARTMENT 20.66 0.02 13-JUN-07:45 4207.39 03-DEC-02:00
Heating:EnergyTransfer:Zone:T NW APARTMENT 17.53 0.00 06-JAN-14:00 4207.39 03-DEC-02:00
Cooling:EnergyTransfer:Zone:T NW APARTMENT 3.14 0.00 01-JAN-00:15 3001.53 15-JUL-17:45
EnergyTransfer:Zone:T SE APARTMENT 20.74 0.00 10-JUL-01:30 4182.43 03-DEC-02:00
Heating:EnergyTransfer:Zone:T SE APARTMENT 15.08 0.00 01-JAN-10:00 4182.43 03-DEC-02:00
Cooling:EnergyTransfer:Zone:T SE APARTMENT 5.66 0.00 01-JAN-00:15 3343.28 11-JUL-13:00
EnergyTransfer:Zone:T NE APARTMENT 20.14 0.03 08-JUN-12:15 4199.43 03-DEC-02:00
Heating:EnergyTransfer:Zone:T NE APARTMENT 17.41 0.00 05-FEB-09:30 4199.43 03-DEC-02:00
Cooling:EnergyTransfer:Zone:T NE APARTMENT 2.73 0.00 01-JAN-00:15 2162.36 11-JUL-13:45
EnergyTransfer:Zone:T N1 APARTMENT 12.17 0.01 31-JUL-07:00 3204.45 01-SEP-12:45
Heating:EnergyTransfer:Zone:T N1 APARTMENT 9.31 0.00 06-JAN-14:00 3204.45 01-SEP-12:45
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 2.86 0.00 01-JAN-00:15 1586.16 11-JUL-14:00
EnergyTransfer:Zone:T N2 APARTMENT 12.14 0.01 01-AUG-19:15 3208.76 01-SEP-12:45
Heating:EnergyTransfer:Zone:T N2 APARTMENT 9.32 0.00 06-JAN-14:00 3208.76 01-SEP-12:45
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 2.82 0.00 01-JAN-00:15 1588.90 11-JUL-14:00
EnergyTransfer:Zone:T S1 APARTMENT 12.99 0.01 23-JUN-10:00 3053.37 01-SEP-12:45
Heating:EnergyTransfer:Zone:T S1 APARTMENT 7.31 0.00 01-JAN-09:45 3053.37 01-SEP-12:45
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 5.68 0.00 01-JAN-00:15 2826.81 11-JUL-13:00
EnergyTransfer:Zone:T S2 APARTMENT 12.99 0.01 05-JUN-00:45 3055.77 01-SEP-12:45
Heating:EnergyTransfer:Zone:T S2 APARTMENT 7.33 0.00 01-JAN-09:45 3055.77 01-SEP-12:45
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 5.67 0.00 01-JAN-00:15 2843.33 11-JUL-13:00
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Plant 1496.03 505.43 11-AUG-01:15 187074.50 16-DEC-19:00
WaterSystems:EnergyTransfer 917.60 505.43 11-AUG-01:15 59367.80 16-FEB-07:30
sub cat:WaterSystems:EnergyTransfer 917.60 505.43 11-AUG-01:15 59367.80 16-FEB-07:30
EnergyTransfer:HVAC 1113.06 0.00 03-MAY-06:00 217722.90 16-DEC-17:00
CoolingCoils:EnergyTransfer 303.45 0.00 01-JAN-00:15 190291.50 11-JUL-17:00
HeatingCoils:EnergyTransfer 809.61 0.00 25-MAR-16:30 217722.90 16-DEC-17:00
PlantLoopHeatingDemand:HVAC 620.70 0.00 25-MAR-16:30 147676.03 16-DEC-17:00
HeatingCoils:PlantLoopHeatingDemand 620.70 0.00 25-MAR-16:30 147676.03 16-DEC-17:00
Boilers:EnergyTransfer 578.43 0.00 06-FEB-16:15 145857.15 16-DEC-17:00



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:21

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 7.007 -4.272 0.000 0.000 3.892 1.087 12.213 17.198 0.000 0.001 0.000 0.000 -12.641 0.000 -9.786 -14.698
G NW APARTMENT 8.876 -2.520 0.000 0.000 3.946 1.087 12.213 8.558 0.000 0.001 0.000 0.000 -12.548 0.000 -9.090 -10.522
OFFICE 4.788 -13.002 0.000 0.000 0.529 29.882 9.495 16.107 0.000 0.000 0.000 0.000 -12.756 0.000 -5.556 -29.487
G NE APARTMENT 8.925 -2.539 0.000 0.000 3.969 1.087 12.213 7.600 0.000 0.001 0.000 0.000 -12.341 0.000 -9.030 -9.885
G N1 APARTMENT 4.395 -2.974 0.000 0.000 3.976 1.087 12.213 2.594 0.000 0.001 0.000 0.000 -7.686 0.000 -6.531 -7.073
G N2 APARTMENT 4.402 -2.953 0.000 0.000 3.977 1.087 12.213 2.594 0.000 0.001 0.000 0.000 -7.681 0.000 -6.528 -7.111
G S1 APARTMENT 2.715 -4.475 0.000 0.000 3.891 1.087 12.213 11.324 0.000 0.001 0.000 0.000 -7.765 0.000 -7.419 -11.571
G S2 APARTMENT 2.545 -4.606 0.000 0.000 3.885 1.087 12.213 11.306 0.000 0.001 0.000 0.000 -7.787 0.000 -7.483 -11.160
F2 SW APARTMENT 5.812 -7.802 0.000 0.000 3.818 1.087 12.213 16.661 0.000 0.001 0.000 0.000 -13.397 0.000 -13.065 -5.328
F2 NW APARTMENT 7.925 -3.838 0.000 0.000 3.894 1.087 12.213 8.155 0.000 0.001 0.000 0.000 -13.168 0.000 -12.260 -4.009
F2 SE APARTMENT 5.086 -8.270 0.000 0.000 3.810 1.087 12.213 15.641 0.000 0.001 0.000 0.000 -13.357 0.000 -13.242 -2.969
F2 NE APARTMENT 7.922 -3.567 0.000 0.000 3.917 1.087 12.213 7.218 0.000 0.001 0.000 0.000 -12.941 0.000 -12.196 -3.654
F2 N1 APARTMENT 2.722 -4.178 0.000 0.000 3.921 1.087 12.213 2.375 0.000 0.001 0.000 0.000 -8.123 0.000 -8.706 -1.312
F2 N2 APARTMENT 2.731 -4.175 0.000 0.000 3.924 1.087 12.213 2.377 0.000 0.001 0.000 0.000 -8.116 0.000 -8.695 -1.345
F2 S1 APARTMENT 1.690 -7.708 0.000 0.000 3.801 1.087 12.213 10.990 0.000 0.001 0.000 0.000 -8.265 0.000 -9.783 -4.025
F2 S2 APARTMENT 1.664 -7.801 0.000 0.000 3.799 1.087 12.213 10.985 0.000 0.001 0.001 0.000 -8.274 0.000 -9.803 -3.871
F3 SW APARTMENT 5.884 -8.434 0.000 0.000 3.808 1.087 12.213 16.456 0.000 0.001 0.001 0.000 -13.610 0.000 -14.818 -2.587
F3 NW APARTMENT 8.024 -4.219 0.000 0.000 3.885 1.087 12.213 8.010 0.000 0.001 0.000 0.000 -13.364 0.000 -13.961 -1.675
F3 SE APARTMENT 5.764 -8.024 0.000 0.000 3.815 1.087 12.213 15.499 0.000 0.001 0.001 0.000 -13.453 0.000 -14.872 -2.028
F3 NE APARTMENT 8.020 -3.905 0.000 0.000 3.907 1.087 12.213 7.086 0.000 0.001 0.000 0.000 -13.138 0.000 -13.889 -1.382
F3 N1 APARTMENT 2.599 -4.624 0.000 0.000 3.905 1.087 12.213 2.300 0.000 0.001 0.655 0.000 -8.268 0.000 -9.869 -0.000
F3 N2 APARTMENT 2.608 -4.615 0.000 0.000 3.908 1.087 12.213 2.302 0.000 0.001 0.614 0.000 -8.260 0.000 -9.856 -0.000
F3 S1 APARTMENT 1.613 -8.725 0.000 0.000 3.782 1.087 12.213 10.856 0.000 0.001 0.001 0.000 -8.431 0.000 -10.987 -1.408
F3 S2 APARTMENT 1.610 -8.730 0.000 0.000 3.782 1.087 12.213 10.853 0.000 0.001 0.001 0.000 -8.431 0.000 -10.993 -1.392
F4 SW APARTMENT 6.277 -8.521 0.000 0.000 3.807 1.087 12.213 16.330 0.000 0.002 0.001 0.000 -13.704 0.000 -15.694 -1.797
F4 NW APARTMENT 8.494 -4.309 0.000 0.000 3.883 1.087 12.213 7.925 0.000 0.001 0.000 0.000 -13.464 0.000 -14.836 -0.993
F4 SE APARTMENT 6.276 -7.951 0.000 0.000 3.816 1.087 12.213 15.392 0.000 0.002 0.001 0.000 -13.527 0.000 -15.727 -1.580
F4 NE APARTMENT 8.487 -3.986 0.000 0.000 3.904 1.087 12.213 7.010 0.000 0.001 0.000 0.000 -13.239 0.000 -14.766 -0.711
F4 N1 APARTMENT 2.777 -4.760 0.000 0.000 3.898 1.087 12.213 2.258 0.000 0.001 1.227 0.000 -8.345 0.000 -10.355 -0.000
F4 N2 APARTMENT 2.787 -4.750 0.000 0.000 3.900 1.087 12.213 2.259 0.000 0.001 1.183 0.000 -8.337 0.000 -10.342 -0.000
F4 S1 APARTMENT 1.745 -9.013 0.000 0.000 3.777 1.087 12.213 10.773 0.000 0.001 0.000 0.000 -8.504 0.000 -11.449 -0.630
F4 S2 APARTMENT 1.748 -8.988 0.000 0.000 3.777 1.087 12.213 10.772 0.000 0.001 0.001 0.000 -8.501 0.000 -11.451 -0.658
M SW APARTMENT 6.596 -8.392 0.000 0.000 3.809 1.087 12.213 16.234 0.000 0.002 0.001 0.000 -13.778 0.000 -16.764 -1.006
M NW APARTMENT 8.819 -4.281 0.000 0.000 3.884 1.087 12.213 7.866 0.000 0.001 0.000 0.000 -13.542 0.000 -15.856 -0.190
M SE APARTMENT 6.612 -7.796 0.000 0.000 3.818 1.087 12.213 15.305 0.000 0.002 0.001 0.000 -13.597 0.000 -16.790 -0.854
M NE APARTMENT 8.807 -3.961 0.000 0.000 3.905 1.087 12.213 6.959 0.000 0.001 0.089 0.000 -13.319 0.000 -15.779 -0.000
M N1 APARTMENT 2.888 -4.820 0.000 0.000 3.896 1.087 12.213 2.231 0.000 0.001 1.937 0.000 -8.403 0.000 -11.030 -0.000
M N2 APARTMENT 2.897 -4.808 0.000 0.000 3.899 1.087 12.213 2.233 0.000 0.001 1.891 0.000 -8.396 0.000 -11.017 -0.000
M S1 APARTMENT 1.853 -9.033 0.000 0.000 3.777 1.087 12.213 10.712 0.000 0.001 0.112 0.000 -8.556 0.000 -12.165 -0.000
M S2 APARTMENT 1.858 -9.000 0.000 0.000 3.777 1.087 12.213 10.711 0.000 0.001 0.072 0.000 -8.553 0.000 -12.166 -0.000
F6 SW APARTMENT 7.365 -7.631 0.000 0.000 3.818 1.087 12.213 16.188 0.000 0.002 0.000 0.000 -13.762 0.000 -17.614 -1.665
F6 NW APARTMENT 9.769 -3.847 0.000 0.000 3.894 1.087 12.213 7.855 0.000 0.001 0.000 0.000 -13.530 0.000 -16.626 -0.816
F6 SE APARTMENT 7.387 -7.054 0.000 0.000 3.829 1.087 12.213 15.266 0.000 0.002 0.002 0.000 -13.581 0.000 -17.632 -1.516
F6 NE APARTMENT 9.759 -3.569 0.000 0.000 3.916 1.087 12.213 6.955 0.000 0.001 0.000 0.000 -13.308 0.000 -16.537 -0.517
F6 N1 APARTMENT 3.413 -4.421 0.000 0.000 3.908 1.087 12.213 2.234 0.000 0.001 1.440 0.000 -8.394 0.000 -11.483 -0.000
F6 N2 APARTMENT 3.426 -4.412 0.000 0.000 3.911 1.087 12.213 2.236 0.000 0.001 1.394 0.000 -8.386 0.000 -11.469 -0.000
F6 S1 APARTMENT 2.206 -8.287 0.000 0.000 3.788 1.087 12.213 10.682 0.000 0.001 0.002 0.000 -8.543 0.000 -12.701 -0.445
F6 S2 APARTMENT 2.214 -8.254 0.000 0.000 3.788 1.087 12.213 10.681 0.000 0.001 0.003 0.000 -8.540 0.000 -12.702 -0.488
F7 SW APARTMENT 7.981 -7.108 0.000 0.000 3.826 1.087 12.213 16.144 0.000 0.002 0.001 0.000 -13.762 0.000 -18.359 -2.024
F7 NW APARTMENT 10.487 -3.558 0.000 0.000 3.902 1.087 12.213 7.840 0.000 0.001 0.000 0.000 -13.533 0.000 -17.309 -1.130
F7 SE APARTMENT 8.003 -6.551 0.000 0.000 3.836 1.087 12.213 15.228 0.000 0.002 0.000 0.000 -13.580 0.000 -18.370 -1.866
F7 NE APARTMENT 10.480 -3.317 0.000 0.000 3.924 1.087 12.213 6.948 0.000 0.001 0.000 0.000 -13.311 0.000 -17.206 -0.819
F7 N1 APARTMENT 3.811 -4.158 0.000 0.000 3.918 1.087 12.213 2.235 0.000 0.001 1.174 0.000 -8.393 0.000 -11.886 -0.000
F7 N2 APARTMENT 3.822 -4.151 0.000 0.000 3.920 1.087 12.213 2.237 0.000 0.001 1.130 0.000 -8.386 0.000 -11.871 -0.000
F7 S1 APARTMENT 2.495 -7.769 0.000 0.000 3.796 1.087 12.213 10.653 0.000 0.001 0.001 0.000 -8.539 0.000 -13.170 -0.768
F7 S2 APARTMENT 2.504 -7.736 0.000 0.000 3.797 1.087 12.213 10.652 0.000 0.001 0.000 0.000 -8.536 0.000 -13.171 -0.812
F8 SW APARTMENT 8.594 -6.649 0.000 0.000 3.832 1.087 12.213 16.107 0.000 0.002 0.000 0.000 -13.760 0.000 -19.056 -2.369
F8 NW APARTMENT 11.180 -3.324 0.000 0.000 3.909 1.087 12.213 7.827 0.000 0.001 0.000 0.000 -13.538 0.000 -17.952 -1.402
F8 SE APARTMENT 8.612 -6.115 0.000 0.000 3.844 1.087 12.213 15.195 0.000 0.002 0.000 0.000 -13.579 0.000 -19.063 -2.195
F8 NE APARTMENT 11.175 -3.114 0.000 0.000 3.931 1.087 12.213 6.941 0.000 0.001 0.000 0.000 -13.318 0.000 -17.838 -1.077
F8 N1 APARTMENT 4.228 -3.946 0.000 0.000 3.925 1.087 12.213 2.235 0.000 0.001 0.934 0.000 -8.395 0.000 -12.281 -0.000
F8 N2 APARTMENT 4.241 -3.942 0.000 0.000 3.928 1.087 12.213 2.236 0.000 0.001 0.889 0.000 -8.387 0.000 -12.265 -0.001
F8 S1 APARTMENT 2.802 -7.302 0.000 0.000 3.805 1.087 12.213 10.630 0.000 0.001 0.000 0.000 -8.533 0.000 -13.618 -1.084
F8 S2 APARTMENT 2.810 -7.268 0.000 0.000 3.805 1.087 12.213 10.629 0.000 0.001 0.001 0.000 -8.529 0.000 -13.618 -1.129
F9 SW APARTMENT 9.797 -6.137 0.000 0.000 3.841 1.087 12.213 16.093 0.000 0.002 0.000 0.000 -13.714 0.000 -19.647 -3.534
F9 NW APARTMENT 12.538 -3.108 0.000 0.000 3.914 1.087 12.213 7.827 0.000 0.001 0.000 0.000 -13.516 0.000 -18.515 -2.442
F9 SE APARTMENT 9.803 -5.597 0.000 0.000 3.853 1.087 12.213 15.185 0.000 0.002 0.000 0.000 -13.537 0.000 -19.662 -3.345
F9 NE APARTMENT 12.511 -2.945 0.000 0.000 3.938 1.087 12.213 6.945 0.000 0.001 0.000 0.000 -13.297 0.000 -18.400 -2.052
F9 N1 APARTMENT 5.154 -3.617 0.000 0.000 3.930 1.087 12.213 2.239 0.000 0.001 0.006 0.000 -8.378 0.000 -12.635 -0.000
F9 N2 APARTMENT 5.166 -3.612 0.000 0.000 3.933 1.087 12.213 2.241 0.000 0.001 0.000 0.000 -8.371 0.000 -12.621 -0.036
F9 S1 APARTMENT 3.482 -6.635 0.000 0.000 3.816 1.087 12.213 10.621 0.000 0.001 0.000 0.000 -8.495 0.000 -13.991 -2.099
F9 S2 APARTMENT 3.492 -6.607 0.000 0.000 3.817 1.087 12.213 10.620 0.000 0.001 0.000 0.000 -8.491 0.000 -13.992 -2.140
T SW APARTMENT 15.157 -6.338 0.000 0.000 3.886 1.087 12.213 15.886 0.000 0.001 0.000 0.000 -13.127 0.000 -20.082 -8.684
T NW APARTMENT 17.525 -3.135 0.000 0.000 3.942 1.087 12.213 7.672 0.000 0.001 0.000 0.000 -13.032 0.000 -19.082 -7.189
T SE APARTMENT 15.077 -5.660 0.000 0.000 3.897 1.087 12.213 15.009 0.000 0.001 0.000 0.000 -12.988 0.000 -20.118 -8.519
T NE APARTMENT 17.405 -2.731 0.000 0.000 3.964 1.087 12.213 6.812 0.000 0.001 0.000 0.000 -12.851 0.000 -19.024 -6.876
T N1 APARTMENT 9.305 -2.862 0.000 0.000 3.954 1.087 12.213 2.190 0.000 0.001 0.000 0.000 -8.069 0.000 -13.081 -4.737
T N2 APARTMENT 9.321 -2.823 0.000 0.000 3.956 1.087 12.213 2.188 0.000 0.001 0.000 0.000 -8.061 0.000 -13.081 -4.800
T S1 APARTMENT 7.310 -5.680 0.000 0.000 3.862 1.087 12.213 10.516 0.000 0.001 0.000 0.000 -8.166 0.000 -14.280 -6.863
T S2 APARTMENT 7.326 -5.665 0.000 0.000 3.863 1.087 12.213 10.513 0.000 0.001 0.000 0.000 -8.160 0.000 -14.284 -6.893
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 3.604 0.000 0.000 44.120 0.000 -2.764 0.000 -61.401 -0.001
F2 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.683 0.000 0.000 0.000 0.000 -1.698 0.000 -1.421 -15.004
F3 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.645 0.000 0.000 0.000 0.000 -1.764 0.000 -1.732 -14.589
F4 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.625 0.000 0.000 0.000 0.000 -1.792 0.000 -1.956 -14.316
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 32.880 0.000 1.602 0.000 0.000 0.000 0.000 -1.836 0.000 -2.215 -30.431
F6 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.611 0.000 0.000 0.000 0.000 -1.800 0.000 -2.265 -13.987
F7 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.612 0.000 0.000 0.000 0.000 -1.788 0.000 -2.370 -13.894
F8 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.610 0.000 0.000 0.000 0.000 -1.784 0.000 -2.472 -13.793
F9 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.610 0.000 0.000 0.000 0.000 -1.775 0.000 -2.558 -13.717
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 8.151 1.571 0.000 0.000 0.000 0.000 -1.726 0.000 -2.714 -21.723
Total Facility 503.379 -446.960 0.000 0.000 306.385 296.560 982.450 746.581 0.000 0.107 58.889 0.000 -884.669 0.000 -1172.002 -390.702


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 13-SEP-15:15 0.00 -2312.33 0.00 0.00 48.90 45.40 470.89 3819.28 0.00 0.00 0.00 0.00 0.00 0.00 -115.89 -1956.25
G NW APARTMENT 15-JUL-18:00 0.00 -1787.42 0.00 0.00 141.76 87.56 588.62 2776.33 0.00 0.00 0.00 0.00 0.00 0.00 -77.68 -1729.17
OFFICE 13-SEP-13:15 0.00 -3592.99 0.00 0.00 65.20 2345.88 588.62 3432.03 0.00 0.00 0.00 0.00 0.00 0.00 -25.65 -2813.08
G NE APARTMENT 11-JUL-16:45 0.00 -1101.44 0.00 0.00 84.76 64.86 588.62 617.76 0.00 104.41 0.00 0.00 0.00 0.00 0.00 -358.97
G N1 APARTMENT 03-JUL-19:00 0.00 -732.95 0.00 0.00 141.82 103.77 547.42 655.10 0.00 0.00 0.00 0.00 0.00 0.00 -0.02 -715.13
G N2 APARTMENT 03-JUL-19:00 0.00 -732.67 0.00 0.00 141.82 103.77 547.42 655.35 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -715.68
G S1 APARTMENT 13-SEP-13:45 0.00 -1642.33 0.00 0.00 40.75 12.97 382.60 2971.63 0.00 0.00 0.00 0.00 0.00 0.00 -170.97 -1594.66
G S2 APARTMENT 13-SEP-13:45 0.00 -1700.08 0.00 0.00 40.75 12.97 382.60 2970.46 0.00 0.00 0.00 0.00 0.00 0.00 -170.97 -1535.73
F2 SW APARTMENT 13-SEP-15:15 0.00 -2999.03 0.00 0.00 48.90 45.40 470.89 3773.89 0.00 0.00 0.00 0.00 0.00 0.00 -144.56 -1195.50
F2 NW APARTMENT 15-JUL-18:00 0.00 -2385.20 0.00 0.00 141.76 87.56 588.62 2752.17 0.00 0.00 0.00 0.00 0.00 0.00 -86.01 -1098.90
F2 SE APARTMENT 13-SEP-13:30 0.00 -2768.31 0.00 0.00 40.75 12.97 382.60 3275.72 0.00 0.00 0.00 0.00 0.00 0.00 -233.83 -709.91
F2 NE APARTMENT 11-JUL-16:30 0.00 -1591.05 0.00 0.00 84.76 64.86 588.62 651.72 0.00 81.15 119.94 0.00 0.00 0.00 0.00 0.00
F2 N1 APARTMENT 11-JUL-21:10 0.00 -1086.29 0.00 0.00 168.33 38.91 417.92 0.00 0.00 0.00 764.26 0.00 -241.28 0.00 -61.85 0.00
F2 N2 APARTMENT 14-JUL-21:10 0.00 -1066.19 0.00 0.00 166.14 38.91 417.92 0.00 0.00 0.00 691.73 0.00 -237.51 0.00 -11.00 0.00
F2 S1 APARTMENT 13-SEP-13:45 0.00 -2219.24 0.00 0.00 40.75 12.97 382.60 2943.25 0.00 0.00 0.00 0.00 0.00 0.00 -201.28 -959.05
F2 S2 APARTMENT 13-SEP-13:45 0.00 -2239.66 0.00 0.00 40.75 12.97 382.60 2942.92 0.00 0.00 0.00 0.00 0.00 0.00 -201.28 -938.30
F3 SW APARTMENT 13-SEP-15:15 0.00 -3016.14 0.00 0.00 48.90 45.40 470.89 3749.76 0.00 0.00 0.00 0.00 0.00 0.00 -164.83 -1133.98
F3 NW APARTMENT 15-JUL-18:00 0.00 -2428.40 0.00 0.00 141.62 87.56 588.62 2741.44 0.00 0.00 0.00 0.00 0.00 0.00 -93.90 -1036.94
F3 SE APARTMENT 13-SEP-13:30 0.00 -2653.07 0.00 0.00 40.75 12.97 382.60 3262.07 0.00 0.00 0.00 0.00 0.00 0.00 -258.73 -786.60
F3 NE APARTMENT 11-JUL-16:15 0.00 -1636.00 0.00 0.00 84.76 64.86 588.62 710.65 0.00 60.88 126.23 0.00 0.00 0.00 0.00 0.00
F3 N1 APARTMENT 11-JUL-21:10 0.00 -1133.83 0.00 0.00 167.80 38.91 417.92 0.00 0.00 0.00 827.11 0.00 -244.24 0.00 -73.67 0.00
F3 N2 APARTMENT 11-JUL-21:10 0.00 -1111.44 0.00 0.00 167.93 38.91 417.92 0.00 0.00 0.00 804.39 0.00 -243.94 0.00 -73.77 0.00
F3 S1 APARTMENT 13-SEP-13:45 0.00 -2258.18 0.00 0.00 40.75 12.97 382.60 2928.72 0.00 0.00 0.00 0.00 0.00 0.00 -223.14 -883.72
F3 S2 APARTMENT 13-SEP-13:45 0.00 -2269.27 0.00 0.00 40.75 12.97 382.60 2928.52 0.00 0.00 0.00 0.00 0.00 0.00 -223.14 -872.44
F4 SW APARTMENT 11-JUL-17:15 0.00 -3019.28 0.00 0.00 141.82 87.56 588.62 2793.44 0.00 81.85 0.00 0.00 0.00 0.00 0.00 -674.01
F4 NW APARTMENT 15-JUL-18:00 0.00 -2437.31 0.00 0.00 141.63 87.56 588.62 2734.20 0.00 0.00 0.00 0.00 0.00 0.00 -99.26 -1015.44
F4 SE APARTMENT 13-SEP-13:30 0.00 -2629.73 0.00 0.00 40.75 12.97 382.60 3250.82 0.00 0.00 0.00 0.00 0.00 0.00 -279.55 -777.87
F4 NE APARTMENT 09-JUN-08:55 0.00 -1973.83 0.00 0.00 42.33 12.97 394.37 2217.05 0.00 0.00 0.00 0.00 0.00 0.00 -296.81 -396.08
F4 N1 APARTMENT 06-JUL-20:00 0.00 -1186.91 0.00 0.00 150.72 103.77 523.87 151.07 0.00 0.00 346.94 0.00 0.00 0.00 -89.46 0.00
F4 N2 APARTMENT 06-JUL-20:00 0.00 -1202.04 0.00 0.00 151.07 103.77 523.87 152.24 0.00 0.00 360.55 0.00 0.00 0.00 -89.46 0.00
F4 S1 APARTMENT 13-SEP-13:45 0.00 -2256.02 0.00 0.00 40.75 12.97 382.60 2918.60 0.00 0.00 0.00 0.00 0.00 0.00 -241.51 -857.40
F4 S2 APARTMENT 13-SEP-13:45 0.00 -2265.61 0.00 0.00 40.75 12.97 382.60 2918.43 0.00 0.00 0.00 0.00 0.00 0.00 -241.51 -847.63
M SW APARTMENT 11-JUL-17:15 0.00 -3044.16 0.00 0.00 141.82 87.56 588.62 2789.99 0.00 81.91 0.00 0.00 0.00 0.00 0.00 -645.73
M NW APARTMENT 15-JUL-18:00 0.00 -2463.04 0.00 0.00 141.70 87.56 588.62 2727.75 0.00 0.00 0.00 0.00 0.00 0.00 -103.54 -979.04
M SE APARTMENT 11-JUL-13:00 0.00 -2645.23 0.00 0.00 40.75 12.97 388.49 2639.90 0.00 163.30 0.00 0.00 0.00 0.00 0.00 -600.18
M NE APARTMENT 09-JUN-08:55 0.00 -1996.99 0.00 0.00 42.44 12.97 394.37 2206.69 0.00 0.00 0.00 0.00 0.00 0.00 -322.86 -336.63
M N1 APARTMENT 06-JUL-20:00 0.00 -1195.25 0.00 0.00 150.83 103.77 523.87 149.23 0.00 0.00 364.97 0.00 0.00 0.00 -97.42 0.00
M N2 APARTMENT 06-JUL-20:00 0.00 -1210.38 0.00 0.00 151.19 103.77 523.87 150.43 0.00 0.00 378.54 0.00 0.00 0.00 -97.42 0.00
M S1 APARTMENT 13-SEP-13:45 0.00 -2262.87 0.00 0.00 40.75 12.97 382.60 2910.34 0.00 0.00 0.00 0.00 0.00 0.00 -257.87 -825.92
M S2 APARTMENT 13-SEP-13:45 0.00 -2272.22 0.00 0.00 40.75 12.97 382.60 2910.17 0.00 0.00 0.00 0.00 0.00 0.00 -257.87 -816.41
F6 SW APARTMENT 11-JUL-17:15 0.00 -3006.09 0.00 0.00 141.82 87.56 588.62 2788.43 0.00 81.70 0.00 0.00 0.00 0.00 0.00 -682.04
F6 NW APARTMENT 15-JUL-18:00 0.00 -2422.24 0.00 0.00 141.75 87.56 588.62 2723.79 0.00 0.00 0.00 0.00 0.00 0.00 -107.82 -1011.65
F6 SE APARTMENT 11-JUL-13:00 0.00 -2607.84 0.00 0.00 40.75 12.97 388.49 2636.71 0.00 165.22 0.00 0.00 0.00 0.00 0.00 -636.30
F6 NE APARTMENT 09-JUN-08:55 0.00 -1697.60 0.00 0.00 42.76 12.97 394.37 2202.41 0.00 0.00 0.00 0.00 0.00 0.00 -345.46 -609.44
F6 N1 APARTMENT 06-JUL-20:00 0.00 -1192.87 0.00 0.00 151.79 103.77 523.87 150.51 0.00 0.00 367.25 0.00 0.00 0.00 -104.32 0.00
F6 N2 APARTMENT 11-JUL-21:10 0.00 -1115.34 0.00 0.00 168.44 38.91 417.92 0.00 0.00 0.00 832.31 0.00 -245.97 0.00 -96.27 0.00
F6 S1 APARTMENT 13-SEP-13:45 0.00 -2206.09 0.00 0.00 40.75 12.97 382.60 2904.46 0.00 0.00 0.00 0.00 0.00 0.00 -272.91 -861.78
F6 S2 APARTMENT 13-SEP-13:45 0.00 -2215.45 0.00 0.00 40.75 12.97 382.60 2904.29 0.00 0.00 0.00 0.00 0.00 0.00 -272.91 -852.25
F7 SW APARTMENT 11-JUL-17:15 0.00 -2988.40 0.00 0.00 141.82 87.56 588.62 2786.47 0.00 81.31 0.00 0.00 0.00 0.00 0.00 -697.38
F7 NW APARTMENT 15-JUL-18:00 0.00 -2405.03 0.00 0.00 141.80 87.56 588.62 2719.74 0.00 0.00 0.00 0.00 0.00 0.00 -111.72 -1020.97
F7 SE APARTMENT 11-JUL-13:00 0.00 -2590.30 0.00 0.00 40.75 12.97 388.49 2633.25 0.00 166.67 0.00 0.00 0.00 0.00 0.00 -651.83
F7 NE APARTMENT 11-JUL-16:15 0.00 -1600.08 0.00 0.00 84.76 64.86 588.62 704.88 0.00 61.34 95.62 0.00 0.00 0.00 0.00 0.00
F7 N1 APARTMENT 11-JUL-21:10 0.00 -1122.08 0.00 0.00 168.70 38.91 417.92 0.00 0.00 0.00 844.36 0.00 -246.14 0.00 -101.68 0.00
F7 N2 APARTMENT 12-JUL-21:10 0.00 -1092.00 0.00 0.00 166.30 38.91 417.92 0.00 0.00 0.00 843.56 0.00 -219.71 0.00 -154.98 0.00
F7 S1 APARTMENT 13-SEP-13:45 0.00 -2169.84 0.00 0.00 40.75 12.97 382.60 2899.09 0.00 0.00 0.00 0.00 0.00 0.00 -287.00 -878.57
F7 S2 APARTMENT 13-SEP-13:45 0.00 -2179.22 0.00 0.00 40.75 12.97 382.60 2898.91 0.00 0.00 0.00 0.00 0.00 0.00 -287.00 -869.02
F8 SW APARTMENT 11-JUL-17:15 0.00 -2979.67 0.00 0.00 141.82 87.56 588.62 2784.43 0.00 80.76 0.00 0.00 0.00 0.00 0.00 -703.52
F8 NW APARTMENT 15-JUL-18:00 0.00 -2397.60 0.00 0.00 141.82 87.56 588.62 2715.81 0.00 0.00 0.00 0.00 0.00 0.00 -115.63 -1020.58
F8 SE APARTMENT 11-JUL-13:00 0.00 -2580.53 0.00 0.00 40.75 12.97 388.49 2629.96 0.00 167.74 0.00 0.00 0.00 0.00 0.00 -659.38
F8 NE APARTMENT 11-JUL-16:15 0.00 -1591.64 0.00 0.00 84.76 64.86 588.62 703.87 0.00 61.03 88.50 0.00 0.00 0.00 0.00 0.00
F8 N1 APARTMENT 12-JUL-21:10 0.00 -1115.74 0.00 0.00 166.55 38.91 417.92 0.00 0.00 0.00 875.38 0.00 -220.03 0.00 -162.99 0.00
F8 N2 APARTMENT 12-JUL-21:10 0.00 -1105.06 0.00 0.00 166.70 38.91 417.92 0.00 0.00 0.00 864.15 0.00 -219.63 0.00 -162.99 0.00
F8 S1 APARTMENT 13-SEP-13:45 0.00 -2138.53 0.00 0.00 40.75 12.97 382.60 2894.30 0.00 0.00 0.00 0.00 0.00 0.00 -300.38 -891.72
F8 S2 APARTMENT 13-SEP-13:45 0.00 -2148.00 0.00 0.00 40.75 12.97 382.60 2894.13 0.00 0.00 0.00 0.00 0.00 0.00 -300.38 -882.07
F9 SW APARTMENT 11-JUL-17:15 0.00 -3045.28 0.00 0.00 141.82 87.56 588.62 2780.37 0.00 80.08 0.00 0.00 0.00 0.00 0.00 -633.17
F9 NW APARTMENT 15-JUL-18:00 0.00 -2436.44 0.00 0.00 141.82 87.56 588.62 2710.32 0.00 0.00 0.00 0.00 0.00 0.00 -120.17 -971.70
F9 SE APARTMENT 11-JUL-13:00 0.00 -2600.47 0.00 0.00 40.75 12.97 388.49 2626.04 0.00 168.50 0.00 0.00 0.00 0.00 0.00 -636.28
F9 NE APARTMENT 11-JUL-19:00 0.00 -1624.21 0.00 0.00 141.49 103.77 547.42 614.18 0.00 0.00 300.30 0.00 0.00 0.00 -82.95 0.00
F9 N1 APARTMENT 11-JUL-21:10 0.00 -1178.36 0.00 0.00 168.29 38.91 417.92 0.00 0.00 0.00 914.86 0.00 -249.44 0.00 -112.19 0.00
F9 N2 APARTMENT 11-JUL-21:10 0.00 -1155.24 0.00 0.00 168.43 38.91 417.92 0.00 0.00 0.00 891.26 0.00 -249.07 0.00 -112.21 0.00
F9 S1 APARTMENT 13-SEP-14:15 0.00 -2119.23 0.00 0.00 40.75 22.70 400.26 2576.74 0.00 0.00 0.00 0.00 0.00 0.00 -272.74 -648.48
F9 S2 APARTMENT 13-SEP-14:15 0.00 -2126.60 0.00 0.00 40.75 22.70 400.26 2576.58 0.00 0.00 0.00 0.00 0.00 0.00 -272.74 -640.95
T SW APARTMENT 11-JUL-17:00 0.00 -3680.76 0.00 0.00 84.77 64.86 588.62 2786.00 0.00 124.91 31.61 0.00 0.00 0.00 0.00 0.00
T NW APARTMENT 15-JUL-17:45 0.00 -3001.55 0.00 0.00 141.51 87.56 588.62 2644.19 0.00 0.00 0.00 0.00 0.00 0.00 -107.35 -352.97
T SE APARTMENT 11-JUL-13:00 0.00 -3343.25 0.00 0.00 40.75 12.97 388.49 2583.87 0.00 169.01 148.16 0.00 0.00 0.00 0.00 0.00
T NE APARTMENT 11-JUL-13:45 0.00 -2162.17 0.00 0.00 40.65 12.97 382.60 1008.78 0.00 51.77 665.40 0.00 0.00 0.00 0.00 0.00
T N1 APARTMENT 11-JUL-14:00 0.00 -1586.06 0.00 0.00 40.37 12.97 382.60 619.52 0.00 12.23 518.37 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 11-JUL-14:00 0.00 -1588.79 0.00 0.00 40.34 12.97 382.60 619.16 0.00 11.71 522.00 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 11-JUL-13:00 0.00 -2826.77 0.00 0.00 40.75 12.97 388.49 2225.78 0.00 160.35 0.00 0.00 0.00 0.00 0.00 -1.56
T S2 APARTMENT 11-JUL-13:00 0.00 -2843.29 0.00 0.00 40.75 12.97 388.49 2225.45 0.00 160.35 15.29 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 11-JUL-16:30 0.00 -143031.19 0.00 0.00 6675.37 11327.17 47312.53 91471.64 0.00 5831.92 0.00 0.00 0.00 0.00 -81.37 -19506.09


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 16-DEC-17:00 1864.37 0.00 0.00 0.00 56.90 45.40 470.89 0.00 0.00 0.00 0.00 0.00 -868.05 0.00 -1150.77 -418.74
G NW APARTMENT 16-DEC-17:00 1862.68 0.00 0.00 0.00 56.90 45.40 470.89 0.00 0.00 0.00 0.00 0.00 -866.25 0.00 -1150.77 -418.85
OFFICE 16-DEC-19:00 2022.58 0.00 0.00 0.00 0.00 469.18 194.24 0.00 0.00 0.00 0.00 0.00 -1006.84 0.00 -1114.70 -564.45
G NE APARTMENT 16-DEC-17:00 1867.16 0.00 0.00 0.00 56.90 45.40 470.89 0.00 0.00 0.00 0.00 0.00 -874.24 0.00 -1150.79 -415.32
G N1 APARTMENT 03-MAY-13:55 1325.81 0.00 0.00 0.00 45.95 12.97 382.60 338.18 0.00 0.00 0.00 0.00 0.00 0.00 -1310.77 -794.74
G N2 APARTMENT 05-SEP-08:00 1355.46 0.00 0.00 0.00 68.74 19.46 388.49 80.22 0.00 0.00 0.00 0.00 0.00 0.00 -1666.78 -245.59
G S1 APARTMENT 15-MAY-14:40 1417.28 0.00 0.00 0.00 45.74 22.70 400.26 474.53 0.00 0.00 0.00 0.00 0.00 0.00 -1438.52 -921.99
G S2 APARTMENT 15-MAY-14:40 1105.87 0.00 0.00 0.00 45.36 22.70 400.26 471.01 0.00 0.00 0.00 0.00 0.00 0.00 -1450.34 -594.86
F2 SW APARTMENT 03-DEC-02:00 2278.34 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -749.93 0.00 -1870.30 -95.59
F2 NW APARTMENT 03-DEC-02:00 2299.76 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -758.07 0.00 -1870.31 -108.87
F2 SE APARTMENT 03-DEC-02:00 2240.03 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -744.84 0.00 -1870.30 -62.38
F2 NE APARTMENT 03-DEC-02:00 2289.31 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -751.76 0.00 -1870.31 -104.73
F2 N1 APARTMENT 05-SEP-08:00 1480.05 0.00 0.00 0.00 68.21 19.46 388.49 60.32 0.00 0.00 147.24 0.00 0.00 0.00 -2163.76 0.00
F2 N2 APARTMENT 05-SEP-08:00 1482.65 0.00 0.00 0.00 68.15 19.46 388.49 59.90 0.00 0.00 145.10 0.00 0.00 0.00 -2163.75 0.00
F2 S1 APARTMENT 15-MAY-14:45 1614.78 0.00 0.00 0.00 43.04 22.70 400.26 421.51 0.00 0.00 0.00 0.00 0.00 0.00 -1807.20 -695.09
F2 S2 APARTMENT 15-MAY-14:45 1581.50 0.00 0.00 0.00 42.97 22.70 400.26 420.82 0.00 0.00 0.00 0.00 0.00 0.00 -1808.78 -659.48
F3 SW APARTMENT 03-DEC-02:00 2569.55 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -758.10 0.00 -2216.61 -32.33
F3 NW APARTMENT 03-DEC-02:00 2591.05 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -766.93 0.00 -2216.61 -45.00
F3 SE APARTMENT 03-DEC-02:00 2552.54 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -751.58 0.00 -2216.61 -21.84
F3 NE APARTMENT 03-DEC-02:00 2580.20 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -760.19 0.00 -2216.62 -40.88
F3 N1 APARTMENT 05-SEP-08:00 1538.69 0.00 0.00 0.00 68.38 19.46 388.49 54.46 0.00 0.00 416.95 0.00 0.00 0.00 -2486.43 0.00
F3 N2 APARTMENT 05-SEP-08:00 1541.18 0.00 0.00 0.00 68.34 19.46 388.49 54.19 0.00 0.00 414.75 0.00 0.00 0.00 -2486.41 0.00
F3 S1 APARTMENT 03-DEC-02:00 1374.87 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -460.66 0.00 -1337.00 -14.70
F3 S2 APARTMENT 03-DEC-02:00 1373.63 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -460.70 0.00 -1337.00 -13.42
F4 SW APARTMENT 03-DEC-02:00 2818.34 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -762.67 0.00 -2480.13 -13.03
F4 NW APARTMENT 03-DEC-02:00 2840.40 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -771.84 0.00 -2480.13 -25.92
F4 SE APARTMENT 03-DEC-02:00 2806.11 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -755.68 0.00 -2480.13 -7.80
F4 NE APARTMENT 03-DEC-02:00 2829.38 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -764.87 0.00 -2480.15 -21.85
F4 N1 APARTMENT 05-SEP-08:15 1650.01 0.00 0.00 0.00 43.78 12.97 394.37 63.92 0.00 0.00 578.24 0.00 0.00 0.00 -2743.29 0.00
F4 N2 APARTMENT 05-SEP-08:15 1648.68 0.00 0.00 0.00 43.77 12.97 394.37 63.73 0.00 0.00 579.74 0.00 0.00 0.00 -2743.27 0.00
F4 S1 APARTMENT 15-MAY-14:45 1614.59 0.00 0.00 0.00 42.14 22.70 400.26 391.33 0.00 0.00 0.00 0.00 0.00 0.00 -2252.38 -218.65
F4 S2 APARTMENT 15-MAY-14:45 1617.18 0.00 0.00 0.00 42.14 22.70 400.26 391.33 0.00 0.00 0.00 0.00 0.00 0.00 -2252.46 -221.14
M SW APARTMENT 03-DEC-02:00 3014.87 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 12.59 0.00 -766.86 0.00 -2698.08 0.00
M NW APARTMENT 03-DEC-02:00 3036.29 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.55 0.00 -776.24 0.00 -2698.09 0.00
M SE APARTMENT 03-DEC-02:00 3003.57 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 16.68 0.00 -759.65 0.00 -2698.08 0.00
M NE APARTMENT 03-DEC-02:00 3025.19 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 4.54 0.00 -769.10 0.00 -2698.11 0.00
M N1 APARTMENT 05-SEP-08:10 1980.90 0.00 0.00 0.00 43.78 12.97 394.37 60.10 0.00 0.00 491.63 0.00 0.00 0.00 -2983.75 0.00
M N2 APARTMENT 05-SEP-08:10 1969.10 0.00 0.00 0.00 43.77 12.97 394.37 59.96 0.00 0.00 503.52 0.00 0.00 0.00 -2983.71 0.00
M S1 APARTMENT 15-MAY-14:45 1913.22 0.00 0.00 0.00 42.22 22.70 400.26 386.33 0.00 0.00 0.00 0.00 0.00 0.00 -2411.04 -353.68
M S2 APARTMENT 15-MAY-14:45 1915.59 0.00 0.00 0.00 42.22 22.70 400.26 386.36 0.00 0.00 0.00 0.00 0.00 0.00 -2411.09 -356.04
F6 SW APARTMENT 03-DEC-02:00 3231.68 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -768.02 0.00 -2886.54 -14.61
F6 NW APARTMENT 03-DEC-02:00 3253.92 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -777.57 0.00 -2886.55 -27.29
F6 SE APARTMENT 03-DEC-02:00 3220.39 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -760.71 0.00 -2886.54 -10.62
F6 NE APARTMENT 03-DEC-02:00 3242.73 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -770.34 0.00 -2886.58 -23.30
F6 N1 APARTMENT 05-SEP-08:10 2601.67 0.00 0.00 0.00 44.19 12.97 394.37 62.04 0.00 0.00 49.48 0.00 0.00 0.00 -3164.73 0.00
F6 N2 APARTMENT 05-SEP-08:10 2593.68 0.00 0.00 0.00 44.18 12.97 394.37 61.96 0.00 0.00 57.51 0.00 0.00 0.00 -3164.68 0.00
F6 S1 APARTMENT 05-SEP-08:15 2095.85 0.00 0.00 0.00 41.56 12.97 394.37 987.74 0.00 0.00 0.00 0.00 0.00 0.00 -3157.34 -375.15
F6 S2 APARTMENT 05-SEP-08:15 2103.66 0.00 0.00 0.00 41.48 12.97 394.37 986.92 0.00 0.00 0.00 0.00 0.00 0.00 -3157.55 -381.85
F7 SW APARTMENT 03-DEC-02:00 3412.46 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -769.65 0.00 -3054.08 -26.22
F7 NW APARTMENT 03-DEC-02:00 3434.50 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -779.33 0.00 -3054.10 -38.56
F7 SE APARTMENT 03-DEC-02:00 3401.14 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -762.27 0.00 -3054.08 -22.28
F7 NE APARTMENT 03-DEC-02:00 3423.28 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -772.03 0.00 -3054.12 -34.62
F7 N1 APARTMENT 05-SEP-08:10 3151.87 0.00 0.00 0.00 44.54 12.97 394.37 63.81 0.00 0.00 0.00 0.00 0.00 0.00 -3328.81 -338.75
F7 N2 APARTMENT 05-SEP-08:10 3145.96 0.00 0.00 0.00 44.53 12.97 394.37 63.75 0.00 0.00 0.00 0.00 0.00 0.00 -3328.80 -332.79
F7 S1 APARTMENT 05-SEP-08:15 2119.36 0.00 0.00 0.00 41.93 12.97 394.37 986.07 0.00 0.00 0.00 0.00 0.00 0.00 -3328.46 -226.25
F7 S2 APARTMENT 05-SEP-08:15 2126.18 0.00 0.00 0.00 41.85 12.97 394.37 985.30 0.00 0.00 0.00 0.00 0.00 0.00 -3328.64 -232.04
F8 SW APARTMENT 03-DEC-02:00 3577.43 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -771.11 0.00 -3205.90 -37.91
F8 NW APARTMENT 03-DEC-02:00 3599.18 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -780.89 0.00 -3205.92 -49.86
F8 SE APARTMENT 03-DEC-02:00 3566.06 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -763.66 0.00 -3205.90 -33.99
F8 NE APARTMENT 03-DEC-02:00 3587.92 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -773.52 0.00 -3205.95 -45.94
F8 N1 APARTMENT 05-SEP-08:10 3862.60 0.00 0.00 0.00 44.80 12.97 394.37 64.77 0.00 0.00 0.00 0.00 0.00 0.00 -3527.70 -851.82
F8 N2 APARTMENT 05-SEP-08:10 3797.49 0.00 0.00 0.00 44.79 12.97 394.37 64.72 0.00 0.00 0.00 0.00 0.00 0.00 -3539.58 -774.77
F8 S1 APARTMENT 05-SEP-08:15 2149.91 0.00 0.00 0.00 42.23 12.97 394.37 984.49 0.00 0.00 0.00 0.00 0.00 0.00 -3485.59 -98.39
F8 S2 APARTMENT 05-SEP-08:15 2156.02 0.00 0.00 0.00 42.16 12.97 394.37 983.76 0.00 0.00 0.00 0.00 0.00 0.00 -3485.77 -103.51
F9 SW APARTMENT 03-DEC-02:00 3776.33 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -770.50 0.00 -3345.41 -97.91
F9 NW APARTMENT 03-DEC-02:00 3796.63 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -780.29 0.00 -3345.43 -108.40
F9 SE APARTMENT 03-DEC-02:00 3764.94 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -763.02 0.00 -3345.41 -93.99
F9 NE APARTMENT 03-DEC-02:00 3785.38 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -772.90 0.00 -3345.46 -104.51
F9 N1 APARTMENT 05-SEP-08:10 3715.72 0.00 0.00 0.00 45.00 12.97 394.37 65.62 0.00 0.00 0.00 0.00 0.00 0.00 -3657.87 -575.82
F9 N2 APARTMENT 05-SEP-08:10 3790.79 0.00 0.00 0.00 44.99 12.97 394.37 65.49 0.00 0.00 0.00 0.00 0.00 0.00 -3672.03 -636.59
F9 S1 APARTMENT 15-MAY-14:55 2493.44 0.00 0.00 0.00 44.02 22.70 400.26 449.58 0.00 0.00 0.00 0.00 0.00 0.00 -2975.00 -435.00
F9 S2 APARTMENT 15-MAY-14:55 2493.64 0.00 0.00 0.00 44.02 22.70 400.26 449.56 0.00 0.00 0.00 0.00 0.00 0.00 -2975.17 -435.01
T SW APARTMENT 03-DEC-02:00 4189.19 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -752.72 0.00 -3474.69 -399.27
T NW APARTMENT 03-DEC-02:00 4206.15 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -761.19 0.00 -3474.70 -407.75
T SE APARTMENT 03-DEC-02:00 4181.15 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -745.44 0.00 -3474.69 -398.51
T NE APARTMENT 03-DEC-02:00 4198.25 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -753.94 0.00 -3474.73 -407.06
T N1 APARTMENT 05-SEP-08:25 3521.35 0.00 0.00 0.00 46.07 12.97 394.37 110.18 0.00 0.00 0.00 0.00 0.00 0.00 -3779.59 -305.35
T N2 APARTMENT 05-SEP-08:25 3557.63 0.00 0.00 0.00 45.89 12.97 394.37 107.50 0.00 0.00 0.00 0.00 0.00 0.00 -3779.79 -338.57
T S1 APARTMENT 01-SEP-12:25 3651.22 0.00 0.00 0.00 43.91 12.97 388.49 87.84 0.00 0.00 0.00 0.00 0.00 0.00 -3611.90 -572.53
T S2 APARTMENT 01-SEP-12:25 3654.34 0.00 0.00 0.00 43.91 12.97 388.49 87.92 0.00 0.00 0.00 0.00 0.00 0.00 -3611.92 -575.72
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 03-DEC-02:00 191298.08 0.00 0.00 0.00 14983.93 6715.87 19318.62 0.00 0.00 0.00 0.00 0.00 -50147.48 0.00 -174456.49 -7712.53



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:21

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:21

Sec1.1A-General Information

Data
Weather File Vancouver Int'l BC CAN WYEC2-B-94238 WMO#=718920
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 7836.48
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.50
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
F2 SW APARTMENT 88.25 88.25 0.00 168.00
F2 NW APARTMENT 88.25 88.25 0.00 168.00
F2 SE APARTMENT 88.25 88.25 0.00 168.00
F2 NE APARTMENT 88.25 88.25 0.00 168.00
F2 N1 APARTMENT 88.25 88.25 0.00 168.00
F2 N2 APARTMENT 88.25 88.25 0.00 168.00
F2 S1 APARTMENT 88.25 88.25 0.00 168.00
F2 S2 APARTMENT 88.25 88.25 0.00 168.00
F3 SW APARTMENT 88.25 88.25 0.00 168.00
F3 NW APARTMENT 88.25 88.25 0.00 168.00
F3 SE APARTMENT 88.25 88.25 0.00 168.00
F3 NE APARTMENT 88.25 88.25 0.00 168.00
F3 N1 APARTMENT 88.25 88.25 0.00 168.00
F3 N2 APARTMENT 88.25 88.25 0.00 168.00
F3 S1 APARTMENT 88.25 88.25 0.00 168.00
F3 S2 APARTMENT 88.25 88.25 0.00 168.00
F4 SW APARTMENT 88.25 88.25 0.00 168.00
F4 NW APARTMENT 88.25 88.25 0.00 168.00
F4 SE APARTMENT 88.25 88.25 0.00 168.00
F4 NE APARTMENT 88.25 88.25 0.00 168.00
F4 N1 APARTMENT 88.25 88.25 0.00 168.00
F4 N2 APARTMENT 88.25 88.25 0.00 168.00
F4 S1 APARTMENT 88.25 88.25 0.00 168.00
F4 S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
F6 SW APARTMENT 88.25 88.25 0.00 168.00
F6 NW APARTMENT 88.25 88.25 0.00 168.00
F6 SE APARTMENT 88.25 88.25 0.00 168.00
F6 NE APARTMENT 88.25 88.25 0.00 168.00
F6 N1 APARTMENT 88.25 88.25 0.00 168.00
F6 N2 APARTMENT 88.25 88.25 0.00 168.00
F6 S1 APARTMENT 88.25 88.25 0.00 168.00
F6 S2 APARTMENT 88.25 88.25 0.00 168.00
F7 SW APARTMENT 88.25 88.25 0.00 168.00
F7 NW APARTMENT 88.25 88.25 0.00 168.00
F7 SE APARTMENT 88.25 88.25 0.00 168.00
F7 NE APARTMENT 88.25 88.25 0.00 168.00
F7 N1 APARTMENT 88.25 88.25 0.00 168.00
F7 N2 APARTMENT 88.25 88.25 0.00 168.00
F7 S1 APARTMENT 88.25 88.25 0.00 168.00
F7 S2 APARTMENT 88.25 88.25 0.00 168.00
F8 SW APARTMENT 88.25 88.25 0.00 168.00
F8 NW APARTMENT 88.25 88.25 0.00 168.00
F8 SE APARTMENT 88.25 88.25 0.00 168.00
F8 NE APARTMENT 88.25 88.25 0.00 168.00
F8 N1 APARTMENT 88.25 88.25 0.00 168.00
F8 N2 APARTMENT 88.25 88.25 0.00 168.00
F8 S1 APARTMENT 88.25 88.25 0.00 168.00
F8 S2 APARTMENT 88.25 88.25 0.00 168.00
F9 SW APARTMENT 88.25 88.25 0.00 168.00
F9 NW APARTMENT 88.25 88.25 0.00 168.00
F9 SE APARTMENT 88.25 88.25 0.00 168.00
F9 NE APARTMENT 88.25 88.25 0.00 168.00
F9 N1 APARTMENT 88.25 88.25 0.00 168.00
F9 N2 APARTMENT 88.25 88.25 0.00 168.00
F9 S1 APARTMENT 88.25 88.25 0.00 168.00
F9 S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
G CORRIDOR 77.66 0.00 77.66 0.00
F2 CORRIDOR 77.66 0.00 77.66 0.00
F3 CORRIDOR 77.66 0.00 77.66 0.00
F4 CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
F6 CORRIDOR 77.66 0.00 77.66 0.00
F7 CORRIDOR 77.66 0.00 77.66 0.00
F8 CORRIDOR 77.66 0.00 77.66 0.00
F9 CORRIDOR 77.66 0.00 77.66 0.00
T CORRIDOR 77.66 0.00 77.66 0.00
Totals 7836.48 7059.89 776.58  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 200.25
Number of hours cooling loads not met 6.25
Number of hours not met 206.50


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 296.56 11327.17 0.00 0.00 0.00 0.00
Exterior Lighting 162.51 10364.00 0.00 0.00 0.00 0.00
Space Heating 213.87 63322.24 772.80 183438.27 0.00 0.00
Space Cooling 99.13 0.00 0.00 0.00 0.00 0.00
Pumps 52.23 1677.22 0.00 0.00 0.00 0.00
Heat Rejection 4.24 0.00 0.00 0.00 0.00 0.00
Fans-Interior 553.30 17544.92 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 0.00 0.00 1178.71 74728.68 0.00 0.00
Receptacle Equipment 1137.32 57042.02 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 2555.34   1951.51   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 1137.32 2555.34
Natural Gas 0.00 1951.51
Additional 0.00 0.00
Total 1137.32 4506.85


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 37.84
Space Heating 27.29
Space Cooling 12.65
Fans-Interior 70.61
Service Water Heating 0.00
Receptacle Equipment 145.13
Miscellaneous 32.56
Subtotal 326.08


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 98.62
Service Water Heating 150.41
Miscellaneous -0.00
Subtotal 249.03


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 6.58
Space Heating 21.89
Space Cooling 2.20
Fans-Interior 12.28
Service Water Heating 26.15
Receptacle Equipment 25.24
Miscellaneous 5.66



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:21

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.215826
G NW APARTMENT DIRECT AIR 0.146618
OFFICE DIRECT AIR 0.337541
G NE APARTMENT DIRECT AIR 0.103519
G N1 APARTMENT DIRECT AIR 0.060532
G N2 APARTMENT DIRECT AIR 0.060528
G S1 APARTMENT DIRECT AIR 0.156552
G S2 APARTMENT DIRECT AIR 0.163111
F2 SW APARTMENT DIRECT AIR 0.280801
F2 NW APARTMENT DIRECT AIR 0.196086
F2 SE APARTMENT DIRECT AIR 0.282294
F2 NE APARTMENT DIRECT AIR 0.146185
F2 N1 APARTMENT DIRECT AIR 0.090309
F2 N2 APARTMENT DIRECT AIR 0.088098
F2 S1 APARTMENT DIRECT AIR 0.207860
F2 S2 APARTMENT DIRECT AIR 0.210404
F3 SW APARTMENT DIRECT AIR 0.282039
F3 NW APARTMENT DIRECT AIR 0.198623
F3 SE APARTMENT DIRECT AIR 0.262773
F3 NE APARTMENT DIRECT AIR 0.149341
F3 N1 APARTMENT DIRECT AIR 0.094253
F3 N2 APARTMENT DIRECT AIR 0.092031
F3 S1 APARTMENT DIRECT AIR 0.211281
F3 S2 APARTMENT DIRECT AIR 0.212521
F4 SW APARTMENT DIRECT AIR 0.281865
F4 NW APARTMENT DIRECT AIR 0.198732
F4 SE APARTMENT DIRECT AIR 0.260809
F4 NE APARTMENT DIRECT AIR 0.149324
F4 N1 APARTMENT DIRECT AIR 0.095106
F4 N2 APARTMENT DIRECT AIR 0.092883
F4 S1 APARTMENT DIRECT AIR 0.211879
F4 S2 APARTMENT DIRECT AIR 0.212933
M SW APARTMENT DIRECT AIR 0.283460
M NW APARTMENT DIRECT AIR 0.200480
M SE APARTMENT DIRECT AIR 0.262392
M NE APARTMENT DIRECT AIR 0.150917
M N1 APARTMENT DIRECT AIR 0.097309
M N2 APARTMENT DIRECT AIR 0.095084
M S1 APARTMENT DIRECT AIR 0.214031
M S2 APARTMENT DIRECT AIR 0.215057
F6 SW APARTMENT DIRECT AIR 0.279532
F6 NW APARTMENT DIRECT AIR 0.196653
F6 SE APARTMENT DIRECT AIR 0.258712
F6 NE APARTMENT DIRECT AIR 0.147099
F6 N1 APARTMENT DIRECT AIR 0.094256
F6 N2 APARTMENT DIRECT AIR 0.092048
F6 S1 APARTMENT DIRECT AIR 0.210583
F6 S2 APARTMENT DIRECT AIR 0.211608
F7 SW APARTMENT DIRECT AIR 0.277696
F7 NW APARTMENT DIRECT AIR 0.194923
F7 SE APARTMENT DIRECT AIR 0.257078
F7 NE APARTMENT DIRECT AIR 0.145319
F7 N1 APARTMENT DIRECT AIR 0.093091
F7 N2 APARTMENT DIRECT AIR 0.090893
F7 S1 APARTMENT DIRECT AIR 0.209163
F7 S2 APARTMENT DIRECT AIR 0.210188
F8 SW APARTMENT DIRECT AIR 0.276837
F8 NW APARTMENT DIRECT AIR 0.194203
F8 SE APARTMENT DIRECT AIR 0.256373
F8 NE APARTMENT DIRECT AIR 0.144497
F8 N1 APARTMENT DIRECT AIR 0.092911
F8 N2 APARTMENT DIRECT AIR 0.090724
F8 S1 APARTMENT DIRECT AIR 0.208678
F8 S2 APARTMENT DIRECT AIR 0.209705
F9 SW APARTMENT DIRECT AIR 0.281657
F9 NW APARTMENT DIRECT AIR 0.199302
F9 SE APARTMENT DIRECT AIR 0.259841
F9 NE APARTMENT DIRECT AIR 0.144096
F9 N1 APARTMENT DIRECT AIR 0.097664
F9 N2 APARTMENT DIRECT AIR 0.095452
F9 S1 APARTMENT DIRECT AIR 0.211736
F9 S2 APARTMENT DIRECT AIR 0.212766
T SW APARTMENT DIRECT AIR 0.342443
T NW APARTMENT DIRECT AIR 0.244016
T SE APARTMENT DIRECT AIR 0.316108
T NE APARTMENT DIRECT AIR 0.180179
T N1 APARTMENT DIRECT AIR 0.128306
T N2 APARTMENT DIRECT AIR 0.128475
T S1 APARTMENT DIRECT AIR 0.278397
T S2 APARTMENT DIRECT AIR 0.279401


Branch

Maximum Flow Rate [m3/s]
AIRLOOP G SW MAIN BRANCH 0.215826
AIRLOOP G NW MAIN BRANCH 0.146618
AIRLOOP OFFICE MAIN BRANCH 0.337541
AIRLOOP G NE MAIN BRANCH 0.103519
AIRLOOP G N1 MAIN BRANCH 0.060532
AIRLOOP G N2 MAIN BRANCH 0.060528
AIRLOOP G S1 MAIN BRANCH 0.156552
AIRLOOP G S2 MAIN BRANCH 0.163111
AIRLOOP F2 SW MAIN BRANCH 0.280801
AIRLOOP F2 NW MAIN BRANCH 0.196086
AIRLOOP F2 SE MAIN BRANCH 0.282294
AIRLOOP F2 NE MAIN BRANCH 0.146185
AIRLOOP F2 N1 MAIN BRANCH 0.090309
AIRLOOP F2 N2 MAIN BRANCH 0.088098
AIRLOOP F2 S1 MAIN BRANCH 0.207860
AIRLOOP F2 S2 MAIN BRANCH 0.210404
AIRLOOP F3 SW MAIN BRANCH 0.282039
AIRLOOP F3 NW MAIN BRANCH 0.198623
AIRLOOP F3 SE MAIN BRANCH 0.262773
AIRLOOP F3 NE MAIN BRANCH 0.149341
AIRLOOP F3 N1 MAIN BRANCH 0.094253
AIRLOOP F3 N2 MAIN BRANCH 0.092031
AIRLOOP F3 S1 MAIN BRANCH 0.211281
AIRLOOP F3 S2 MAIN BRANCH 0.212521
AIRLOOP F4 SW MAIN BRANCH 0.281865
AIRLOOP F4 NW MAIN BRANCH 0.198732
AIRLOOP F4 SE MAIN BRANCH 0.260809
AIRLOOP F4 NE MAIN BRANCH 0.149324
AIRLOOP F4 N1 MAIN BRANCH 0.095106
AIRLOOP F4 N2 MAIN BRANCH 0.092883
AIRLOOP F4 S1 MAIN BRANCH 0.211879
AIRLOOP F4 S2 MAIN BRANCH 0.212933
AIRLOOP M SW MAIN BRANCH 0.283460
AIRLOOP M NW MAIN BRANCH 0.200480
AIRLOOP M SE MAIN BRANCH 0.262392
AIRLOOP M NE MAIN BRANCH 0.150917
AIRLOOP M N1 MAIN BRANCH 0.097309
AIRLOOP M N2 MAIN BRANCH 0.095084
AIRLOOP M S1 MAIN BRANCH 0.214031
AIRLOOP M S2 MAIN BRANCH 0.215057
AIRLOOP F6 SW MAIN BRANCH 0.279532
AIRLOOP F6 NW MAIN BRANCH 0.196653
AIRLOOP F6 SE MAIN BRANCH 0.258712
AIRLOOP F6 NE MAIN BRANCH 0.147099
AIRLOOP F6 N1 MAIN BRANCH 0.094256
AIRLOOP F6 N2 MAIN BRANCH 0.092048
AIRLOOP F6 S1 MAIN BRANCH 0.210583
AIRLOOP F6 S2 MAIN BRANCH 0.211608
AIRLOOP F7 SW MAIN BRANCH 0.277696
AIRLOOP F7 NW MAIN BRANCH 0.194923
AIRLOOP F7 SE MAIN BRANCH 0.257078
AIRLOOP F7 NE MAIN BRANCH 0.145319
AIRLOOP F7 N1 MAIN BRANCH 0.093091
AIRLOOP F7 N2 MAIN BRANCH 0.090893
AIRLOOP F7 S1 MAIN BRANCH 0.209163
AIRLOOP F7 S2 MAIN BRANCH 0.210188
AIRLOOP F8 SW MAIN BRANCH 0.276837
AIRLOOP F8 NW MAIN BRANCH 0.194203
AIRLOOP F8 SE MAIN BRANCH 0.256373
AIRLOOP F8 NE MAIN BRANCH 0.144497
AIRLOOP F8 N1 MAIN BRANCH 0.092911
AIRLOOP F8 N2 MAIN BRANCH 0.090724
AIRLOOP F8 S1 MAIN BRANCH 0.208678
AIRLOOP F8 S2 MAIN BRANCH 0.209705
AIRLOOP F9 SW MAIN BRANCH 0.281657
AIRLOOP F9 NW MAIN BRANCH 0.199302
AIRLOOP F9 SE MAIN BRANCH 0.259841
AIRLOOP F9 NE MAIN BRANCH 0.144096
AIRLOOP F9 N1 MAIN BRANCH 0.097664
AIRLOOP F9 N2 MAIN BRANCH 0.095452
AIRLOOP F9 S1 MAIN BRANCH 0.211736
AIRLOOP F9 S2 MAIN BRANCH 0.212766
AIRLOOP T SW MAIN BRANCH 0.342443
AIRLOOP T NW MAIN BRANCH 0.244016
AIRLOOP T SE MAIN BRANCH 0.316108
AIRLOOP T NE MAIN BRANCH 0.180179
AIRLOOP T N1 MAIN BRANCH 0.128306
AIRLOOP T N2 MAIN BRANCH 0.128475
AIRLOOP T S1 MAIN BRANCH 0.278397
AIRLOOP T S2 MAIN BRANCH 0.279401


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
AIRLOOP G SW 0.215826
AIRLOOP G NW 0.146618
AIRLOOP OFFICE 0.337541
AIRLOOP G NE 0.103519
AIRLOOP G N1 0.060532
AIRLOOP G N2 0.060528
AIRLOOP G S1 0.156552
AIRLOOP G S2 0.163111
AIRLOOP F2 SW 0.280801
AIRLOOP F2 NW 0.196086
AIRLOOP F2 SE 0.282294
AIRLOOP F2 NE 0.146185
AIRLOOP F2 N1 0.090309
AIRLOOP F2 N2 0.088098
AIRLOOP F2 S1 0.207860
AIRLOOP F2 S2 0.210404
AIRLOOP F3 SW 0.282039
AIRLOOP F3 NW 0.198623
AIRLOOP F3 SE 0.262773
AIRLOOP F3 NE 0.149341
AIRLOOP F3 N1 0.094253
AIRLOOP F3 N2 0.092031
AIRLOOP F3 S1 0.211281
AIRLOOP F3 S2 0.212521
AIRLOOP F4 SW 0.281865
AIRLOOP F4 NW 0.198732
AIRLOOP F4 SE 0.260809
AIRLOOP F4 NE 0.149324
AIRLOOP F4 N1 0.095106
AIRLOOP F4 N2 0.092883
AIRLOOP F4 S1 0.211879
AIRLOOP F4 S2 0.212933
AIRLOOP M SW 0.283460
AIRLOOP M NW 0.200480
AIRLOOP M SE 0.262392
AIRLOOP M NE 0.150917
AIRLOOP M N1 0.097309
AIRLOOP M N2 0.095084
AIRLOOP M S1 0.214031
AIRLOOP M S2 0.215057
AIRLOOP F6 SW 0.279532
AIRLOOP F6 NW 0.196653
AIRLOOP F6 SE 0.258712
AIRLOOP F6 NE 0.147099
AIRLOOP F6 N1 0.094256
AIRLOOP F6 N2 0.092048
AIRLOOP F6 S1 0.210583
AIRLOOP F6 S2 0.211608
AIRLOOP F7 SW 0.277696
AIRLOOP F7 NW 0.194923
AIRLOOP F7 SE 0.257078
AIRLOOP F7 NE 0.145319
AIRLOOP F7 N1 0.093091
AIRLOOP F7 N2 0.090893
AIRLOOP F7 S1 0.209163
AIRLOOP F7 S2 0.210188
AIRLOOP F8 SW 0.276837
AIRLOOP F8 NW 0.194203
AIRLOOP F8 SE 0.256373
AIRLOOP F8 NE 0.144497
AIRLOOP F8 N1 0.092911
AIRLOOP F8 N2 0.090724
AIRLOOP F8 S1 0.208678
AIRLOOP F8 S2 0.209705
AIRLOOP F9 SW 0.281657
AIRLOOP F9 NW 0.199302
AIRLOOP F9 SE 0.259841
AIRLOOP F9 NE 0.144096
AIRLOOP F9 N1 0.097664
AIRLOOP F9 N2 0.095452
AIRLOOP F9 S1 0.211736
AIRLOOP F9 S2 0.212766
AIRLOOP T SW 0.342443
AIRLOOP T NW 0.244016
AIRLOOP T SE 0.316108
AIRLOOP T NE 0.180179
AIRLOOP T N1 0.128306
AIRLOOP T N2 0.128475
AIRLOOP T S1 0.278397
AIRLOOP T S2 0.279401


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
AIRLOOP G SW OA CONTROLLER 0.215826 0.025952
AIRLOOP G NW OA CONTROLLER 0.146618 0.025952
AIRLOOP OFFICE OA CONTROLLER 0.337541 0.038103
AIRLOOP G NE OA CONTROLLER 0.103519 0.025952
AIRLOOP G N1 OA CONTROLLER 0.060532 0.025952
AIRLOOP G N2 OA CONTROLLER 0.060528 0.025952
AIRLOOP G S1 OA CONTROLLER 0.156552 0.025952
AIRLOOP G S2 OA CONTROLLER 0.163111 0.025952
AIRLOOP F2 SW OA CONTROLLER 0.280801 0.025952
AIRLOOP F2 NW OA CONTROLLER 0.196086 0.025952
AIRLOOP F2 SE OA CONTROLLER 0.282294 0.025952
AIRLOOP F2 NE OA CONTROLLER 0.146185 0.025952
AIRLOOP F2 N1 OA CONTROLLER 0.090309 0.025952
AIRLOOP F2 N2 OA CONTROLLER 0.088098 0.025952
AIRLOOP F2 S1 OA CONTROLLER 0.207860 0.025952
AIRLOOP F2 S2 OA CONTROLLER 0.210404 0.025952
AIRLOOP F3 SW OA CONTROLLER 0.282039 0.025952
AIRLOOP F3 NW OA CONTROLLER 0.198623 0.025952
AIRLOOP F3 SE OA CONTROLLER 0.262773 0.025952
AIRLOOP F3 NE OA CONTROLLER 0.149341 0.025952
AIRLOOP F3 N1 OA CONTROLLER 0.094253 0.025952
AIRLOOP F3 N2 OA CONTROLLER 0.092031 0.025952
AIRLOOP F3 S1 OA CONTROLLER 0.211281 0.025952
AIRLOOP F3 S2 OA CONTROLLER 0.212521 0.025952
AIRLOOP F4 SW OA CONTROLLER 0.281865 0.025952
AIRLOOP F4 NW OA CONTROLLER 0.198732 0.025952
AIRLOOP F4 SE OA CONTROLLER 0.260809 0.025952
AIRLOOP F4 NE OA CONTROLLER 0.149324 0.025952
AIRLOOP F4 N1 OA CONTROLLER 0.095106 0.025952
AIRLOOP F4 N2 OA CONTROLLER 0.092883 0.025952
AIRLOOP F4 S1 OA CONTROLLER 0.211879 0.025952
AIRLOOP F4 S2 OA CONTROLLER 0.212933 0.025952
AIRLOOP M SW OA CONTROLLER 0.283460 0.025952
AIRLOOP M NW OA CONTROLLER 0.200480 0.025952
AIRLOOP M SE OA CONTROLLER 0.262392 0.025952
AIRLOOP M NE OA CONTROLLER 0.150917 0.025952
AIRLOOP M N1 OA CONTROLLER 0.097309 0.025952
AIRLOOP M N2 OA CONTROLLER 0.095084 0.025952
AIRLOOP M S1 OA CONTROLLER 0.214031 0.025952
AIRLOOP M S2 OA CONTROLLER 0.215057 0.025952
AIRLOOP F6 SW OA CONTROLLER 0.279532 0.025952
AIRLOOP F6 NW OA CONTROLLER 0.196653 0.025952
AIRLOOP F6 SE OA CONTROLLER 0.258712 0.025952
AIRLOOP F6 NE OA CONTROLLER 0.147099 0.025952
AIRLOOP F6 N1 OA CONTROLLER 0.094256 0.025952
AIRLOOP F6 N2 OA CONTROLLER 0.092048 0.025952
AIRLOOP F6 S1 OA CONTROLLER 0.210583 0.025952
AIRLOOP F6 S2 OA CONTROLLER 0.211608 0.025952
AIRLOOP F7 SW OA CONTROLLER 0.277696 0.025952
AIRLOOP F7 NW OA CONTROLLER 0.194923 0.025952
AIRLOOP F7 SE OA CONTROLLER 0.257078 0.025952
AIRLOOP F7 NE OA CONTROLLER 0.145319 0.025952
AIRLOOP F7 N1 OA CONTROLLER 0.093091 0.025952
AIRLOOP F7 N2 OA CONTROLLER 0.090893 0.025952
AIRLOOP F7 S1 OA CONTROLLER 0.209163 0.025952
AIRLOOP F7 S2 OA CONTROLLER 0.210188 0.025952
AIRLOOP F8 SW OA CONTROLLER 0.276837 0.025952
AIRLOOP F8 NW OA CONTROLLER 0.194203 0.025952
AIRLOOP F8 SE OA CONTROLLER 0.256373 0.025952
AIRLOOP F8 NE OA CONTROLLER 0.144497 0.025952
AIRLOOP F8 N1 OA CONTROLLER 0.092911 0.025952
AIRLOOP F8 N2 OA CONTROLLER 0.090724 0.025952
AIRLOOP F8 S1 OA CONTROLLER 0.208678 0.025952
AIRLOOP F8 S2 OA CONTROLLER 0.209705 0.025952
AIRLOOP F9 SW OA CONTROLLER 0.281657 0.025952
AIRLOOP F9 NW OA CONTROLLER 0.199302 0.025952
AIRLOOP F9 SE OA CONTROLLER 0.259841 0.025952
AIRLOOP F9 NE OA CONTROLLER 0.144096 0.025952
AIRLOOP F9 N1 OA CONTROLLER 0.097664 0.025952
AIRLOOP F9 N2 OA CONTROLLER 0.095452 0.025952
AIRLOOP F9 S1 OA CONTROLLER 0.211736 0.025952
AIRLOOP F9 S2 OA CONTROLLER 0.212766 0.025952
AIRLOOP T SW OA CONTROLLER 0.342443 0.025952
AIRLOOP T NW OA CONTROLLER 0.244016 0.025952
AIRLOOP T SE OA CONTROLLER 0.316108 0.025952
AIRLOOP T NE OA CONTROLLER 0.180179 0.025952
AIRLOOP T N1 OA CONTROLLER 0.128306 0.025952
AIRLOOP T N2 OA CONTROLLER 0.128475 0.025952
AIRLOOP T S1 OA CONTROLLER 0.278397 0.025952
AIRLOOP T S2 OA CONTROLLER 0.279401 0.025952


COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity [W] Rated Sensible Cooling Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP COOLING MODE AIRLOOP G SW 0.215826 3301.54 2450.76 0.000072
HEAT PUMP COOLING MODE AIRLOOP G NW 0.146618 2296.82 1672.42 0.000050
HEAT PUMP COOLING MODE AIRLOOP OFFICE 0.337541 5084.36 3812.04 0.000111
HEAT PUMP COOLING MODE AIRLOOP G NE 0.103519 1656.97 1180.74 0.000036
HEAT PUMP COOLING MODE AIRLOOP G N1 0.060532 1012.32 696.39 0.000022
HEAT PUMP COOLING MODE AIRLOOP G N2 0.060528 1015.61 696.74 0.000022
HEAT PUMP COOLING MODE AIRLOOP G S1 0.156552 2446.12 1794.31 0.000053
HEAT PUMP COOLING MODE AIRLOOP G S2 0.163111 2538.35 1866.42 0.000055
HEAT PUMP COOLING MODE AIRLOOP F2 SW 0.280801 4248.57 3174.90 0.000093
HEAT PUMP COOLING MODE AIRLOOP F2 NW 0.196086 3026.90 2226.05 0.000066
HEAT PUMP COOLING MODE AIRLOOP F2 SE 0.282294 4274.09 3193.58 0.000093
HEAT PUMP COOLING MODE AIRLOOP F2 NE 0.146185 2281.79 1658.55 0.000050
HEAT PUMP COOLING MODE AIRLOOP F2 N1 0.090309 1458.60 1031.49 0.000032
HEAT PUMP COOLING MODE AIRLOOP F2 N2 0.088098 1425.63 1006.67 0.000031
HEAT PUMP COOLING MODE AIRLOOP F2 S1 0.207860 3187.56 2364.19 0.000070
HEAT PUMP COOLING MODE AIRLOOP F2 S2 0.210404 3223.36 2392.18 0.000070
HEAT PUMP COOLING MODE AIRLOOP F3 SW 0.282039 4284.54 3193.70 0.000094
HEAT PUMP COOLING MODE AIRLOOP F3 NW 0.198623 3079.39 2258.76 0.000067
HEAT PUMP COOLING MODE AIRLOOP F3 SE 0.262773 4017.07 2983.73 0.000088
HEAT PUMP COOLING MODE AIRLOOP F3 NE 0.149341 2341.05 1697.58 0.000051
HEAT PUMP COOLING MODE AIRLOOP F3 N1 0.094253 1523.54 1077.63 0.000033
HEAT PUMP COOLING MODE AIRLOOP F3 N2 0.092031 1490.39 1052.69 0.000033
HEAT PUMP COOLING MODE AIRLOOP F3 S1 0.211281 3246.84 2404.97 0.000071
HEAT PUMP COOLING MODE AIRLOOP F3 S2 0.212521 3264.27 2418.61 0.000071
HEAT PUMP COOLING MODE AIRLOOP F4 SW 0.281865 4295.85 3195.65 0.000094
HEAT PUMP COOLING MODE AIRLOOP F4 NW 0.198732 3093.12 2263.46 0.000068
HEAT PUMP COOLING MODE AIRLOOP F4 SE 0.260809 4002.79 2965.89 0.000087
HEAT PUMP COOLING MODE AIRLOOP F4 NE 0.149324 2351.59 1700.56 0.000051
HEAT PUMP COOLING MODE AIRLOOP F4 N1 0.095106 1541.54 1088.83 0.000034
HEAT PUMP COOLING MODE AIRLOOP F4 N2 0.092883 1508.27 1063.84 0.000033
HEAT PUMP COOLING MODE AIRLOOP F4 S1 0.211879 3263.55 2413.90 0.000071
HEAT PUMP COOLING MODE AIRLOOP F4 S2 0.212933 3278.36 2425.48 0.000072
HEAT PUMP COOLING MODE AIRLOOP M SW 0.283460 4329.52 3216.35 0.000095
HEAT PUMP COOLING MODE AIRLOOP M NW 0.200480 3127.84 2285.60 0.000068
HEAT PUMP COOLING MODE AIRLOOP M SE 0.262392 4036.10 2986.42 0.000088
HEAT PUMP COOLING MODE AIRLOOP M NE 0.150917 2382.94 1720.68 0.000052
HEAT PUMP COOLING MODE AIRLOOP M N1 0.097309 1578.24 1114.73 0.000034
HEAT PUMP COOLING MODE AIRLOOP M N2 0.095084 1544.93 1089.72 0.000034
HEAT PUMP COOLING MODE AIRLOOP M S1 0.214031 3300.66 2439.50 0.000072
HEAT PUMP COOLING MODE AIRLOOP M S2 0.215057 3315.10 2450.79 0.000072
HEAT PUMP COOLING MODE AIRLOOP F6 SW 0.279532 4283.41 3175.71 0.000094
HEAT PUMP COOLING MODE AIRLOOP F6 NW 0.196653 3081.49 2245.71 0.000067
HEAT PUMP COOLING MODE AIRLOOP F6 SE 0.258712 3993.20 2948.45 0.000087
HEAT PUMP COOLING MODE AIRLOOP F6 NE 0.147099 2335.57 1680.64 0.000051
HEAT PUMP COOLING MODE AIRLOOP F6 N1 0.094256 1537.18 1081.85 0.000034
HEAT PUMP COOLING MODE AIRLOOP F6 N2 0.092048 1503.94 1056.98 0.000033
HEAT PUMP COOLING MODE AIRLOOP F6 S1 0.210583 3257.67 2403.14 0.000071
HEAT PUMP COOLING MODE AIRLOOP F6 S2 0.211608 3272.10 2414.42 0.000071
HEAT PUMP COOLING MODE AIRLOOP F7 SW 0.277696 4265.64 3157.79 0.000093
HEAT PUMP COOLING MODE AIRLOOP F7 NW 0.194923 3063.90 2228.66 0.000067
HEAT PUMP COOLING MODE AIRLOOP F7 SE 0.257078 3978.07 2932.71 0.000087
HEAT PUMP COOLING MODE AIRLOOP F7 NE 0.145319 2316.23 1662.79 0.000051
HEAT PUMP COOLING MODE AIRLOOP F7 N1 0.093091 1523.20 1069.83 0.000033
HEAT PUMP COOLING MODE AIRLOOP F7 N2 0.090893 1490.01 1045.05 0.000033
HEAT PUMP COOLING MODE AIRLOOP F7 S1 0.209163 3242.58 2388.91 0.000071
HEAT PUMP COOLING MODE AIRLOOP F7 S2 0.210188 3257.02 2400.19 0.000071
HEAT PUMP COOLING MODE AIRLOOP F8 SW 0.276837 4260.80 3150.40 0.000093
HEAT PUMP COOLING MODE AIRLOOP F8 NW 0.194203 3059.92 2222.54 0.000067
HEAT PUMP COOLING MODE AIRLOOP F8 SE 0.256373 3975.22 2926.97 0.000087
HEAT PUMP COOLING MODE AIRLOOP F8 NE 0.144497 2309.84 1655.30 0.000050
HEAT PUMP COOLING MODE AIRLOOP F8 N1 0.092911 1523.36 1068.69 0.000033
HEAT PUMP COOLING MODE AIRLOOP F8 N2 0.090724 1490.25 1044.01 0.000033
HEAT PUMP COOLING MODE AIRLOOP F8 S1 0.208678 3240.17 2384.83 0.000071
HEAT PUMP COOLING MODE AIRLOOP F8 S2 0.209705 3254.64 2396.13 0.000071
HEAT PUMP COOLING MODE AIRLOOP F9 SW 0.281657 4335.87 3205.47 0.000095
HEAT PUMP COOLING MODE AIRLOOP F9 NW 0.199302 3138.96 2280.68 0.000069
HEAT PUMP COOLING MODE AIRLOOP F9 SE 0.259841 4033.47 2968.41 0.000088
HEAT PUMP COOLING MODE AIRLOOP F9 NE 0.144096 2309.30 1652.43 0.000050
HEAT PUMP COOLING MODE AIRLOOP F9 N1 0.097664 1596.30 1122.64 0.000035
HEAT PUMP COOLING MODE AIRLOOP F9 N2 0.095452 1562.89 1097.70 0.000034
HEAT PUMP COOLING MODE AIRLOOP F9 S1 0.211736 3289.87 2420.97 0.000072
HEAT PUMP COOLING MODE AIRLOOP F9 S2 0.212766 3304.39 2432.30 0.000072
HEAT PUMP COOLING MODE AIRLOOP T SW 0.342443 5209.30 3880.80 0.000114
HEAT PUMP COOLING MODE AIRLOOP T NW 0.244016 3789.16 2781.96 0.000083
HEAT PUMP COOLING MODE AIRLOOP T SE 0.316108 4834.41 3589.33 0.000106
HEAT PUMP COOLING MODE AIRLOOP T NE 0.180179 2848.36 2061.68 0.000062
HEAT PUMP COOLING MODE AIRLOOP T N1 0.128306 2104.10 1500.74 0.000046
HEAT PUMP COOLING MODE AIRLOOP T N2 0.128475 2106.64 1502.64 0.000046
HEAT PUMP COOLING MODE AIRLOOP T S1 0.278397 4233.06 3155.17 0.000092
HEAT PUMP COOLING MODE AIRLOOP T S2 0.279401 4247.16 3166.21 0.000093


AirLoopHVAC:UnitaryHeatPump:WaterToAir

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Supplemental Heating Coil Nominal Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
AIRLOOP G SW DXAC HEAT PUMP 0.215826 0.215826 0.215826 0.215826 3301.54 3301.54 2947.58 1.00
AIRLOOP G NW DXAC HEAT PUMP 0.146618 0.146618 0.146618 0.146618 2296.82 2296.82 2952.99 1.00
AIRLOOP OFFICE DXAC HEAT PUMP 0.337541 0.337541 0.337541 0.337541 5084.36 5084.36 3720.93 1.00
AIRLOOP G NE DXAC HEAT PUMP 0.103519 0.103519 0.103519 0.103519 1656.97 1656.97 2949.94 1.00
AIRLOOP G N1 DXAC HEAT PUMP 0.060532 0.060532 0.060532 0.060532 1012.32 1012.32 2241.39 1.00
AIRLOOP G N2 DXAC HEAT PUMP 0.060528 0.060528 0.060528 0.060528 1015.61 1015.61 2241.32 1.00
AIRLOOP G S1 DXAC HEAT PUMP 0.156552 0.156552 0.156552 0.156552 2446.12 2446.12 2232.33 1.00
AIRLOOP G S2 DXAC HEAT PUMP 0.163111 0.163111 0.163111 0.163111 2538.35 2538.35 2238.56 1.00
AIRLOOP F2 SW DXAC HEAT PUMP 0.280801 0.280801 0.280801 0.280801 4248.57 4248.57 2880.32 1.00
AIRLOOP F2 NW DXAC HEAT PUMP 0.196086 0.196086 0.196086 0.196086 3026.90 3026.90 2880.67 1.00
AIRLOOP F2 SE DXAC HEAT PUMP 0.282294 0.282294 0.282294 0.282294 4274.09 4274.09 2896.74 1.00
AIRLOOP F2 NE DXAC HEAT PUMP 0.146185 0.146185 0.146185 0.146185 2281.79 2281.79 2878.42 1.00
AIRLOOP F2 N1 DXAC HEAT PUMP 0.090309 0.090309 0.090309 0.090309 1458.60 1458.60 1997.40 1.00
AIRLOOP F2 N2 DXAC HEAT PUMP 0.088098 0.088098 0.088098 0.088098 1425.63 1425.63 1997.35 1.00
AIRLOOP F2 S1 DXAC HEAT PUMP 0.207860 0.207860 0.207860 0.207860 3187.56 3187.56 1999.80 1.00
AIRLOOP F2 S2 DXAC HEAT PUMP 0.210404 0.210404 0.210404 0.210404 3223.36 3223.36 2000.97 1.00
AIRLOOP F3 SW DXAC HEAT PUMP 0.282039 0.282039 0.282039 0.282039 4284.54 4284.54 2901.57 1.00
AIRLOOP F3 NW DXAC HEAT PUMP 0.198623 0.198623 0.198623 0.198623 3079.39 3079.39 2902.68 1.00
AIRLOOP F3 SE DXAC HEAT PUMP 0.262773 0.262773 0.262773 0.262773 4017.07 4017.07 2902.50 1.00
AIRLOOP F3 NE DXAC HEAT PUMP 0.149341 0.149341 0.149341 0.149341 2341.05 2341.05 2901.54 1.00
AIRLOOP F3 N1 DXAC HEAT PUMP 0.094253 0.094253 0.094253 0.094253 1523.54 1523.54 1973.08 1.00
AIRLOOP F3 N2 DXAC HEAT PUMP 0.092031 0.092031 0.092031 0.092031 1490.39 1490.39 1973.05 1.00
AIRLOOP F3 S1 DXAC HEAT PUMP 0.211281 0.211281 0.211281 0.211281 3246.84 3246.84 1972.75 1.00
AIRLOOP F3 S2 DXAC HEAT PUMP 0.212521 0.212521 0.212521 0.212521 3264.27 3264.27 1972.92 1.00
AIRLOOP F4 SW DXAC HEAT PUMP 0.281865 0.281865 0.281865 0.281865 4295.85 4295.85 2969.72 1.00
AIRLOOP F4 NW DXAC HEAT PUMP 0.198732 0.198732 0.198732 0.198732 3093.12 3093.12 2971.33 1.00
AIRLOOP F4 SE DXAC HEAT PUMP 0.260809 0.260809 0.260809 0.260809 4002.79 4002.79 2969.70 1.00
AIRLOOP F4 NE DXAC HEAT PUMP 0.149324 0.149324 0.149324 0.149324 2351.59 2351.59 2971.09 1.00
AIRLOOP F4 N1 DXAC HEAT PUMP 0.095106 0.095106 0.095106 0.095106 1541.54 1541.54 2004.57 1.00
AIRLOOP F4 N2 DXAC HEAT PUMP 0.092883 0.092883 0.092883 0.092883 1508.27 1508.27 2004.56 1.00
AIRLOOP F4 S1 DXAC HEAT PUMP 0.211879 0.211879 0.211879 0.211879 3263.55 3263.55 2003.47 1.00
AIRLOOP F4 S2 DXAC HEAT PUMP 0.212933 0.212933 0.212933 0.212933 3278.36 3278.36 2003.49 1.00
AIRLOOP M SW DXAC HEAT PUMP 0.283460 0.283460 0.283460 0.283460 4329.52 4329.52 3015.16 1.00
AIRLOOP M NW DXAC HEAT PUMP 0.200480 0.200480 0.200480 0.200480 3127.84 3127.84 3015.94 1.00
AIRLOOP M SE DXAC HEAT PUMP 0.262392 0.262392 0.262392 0.262392 4036.10 4036.10 3015.70 1.00
AIRLOOP M NE DXAC HEAT PUMP 0.150917 0.150917 0.150917 0.150917 2382.94 2382.94 3016.46 1.00
AIRLOOP M N1 DXAC HEAT PUMP 0.097309 0.097309 0.097309 0.097309 1578.24 1578.24 2020.36 1.00
AIRLOOP M N2 DXAC HEAT PUMP 0.095084 0.095084 0.095084 0.095084 1544.93 1544.93 2020.37 1.00
AIRLOOP M S1 DXAC HEAT PUMP 0.214031 0.214031 0.214031 0.214031 3300.66 3300.66 2020.04 1.00
AIRLOOP M S2 DXAC HEAT PUMP 0.215057 0.215057 0.215057 0.215057 3315.10 3315.10 2020.06 1.00
AIRLOOP F6 SW DXAC HEAT PUMP 0.279532 0.279532 0.279532 0.279532 4283.41 4283.41 3114.74 1.00
AIRLOOP F6 NW DXAC HEAT PUMP 0.196653 0.196653 0.196653 0.196653 3081.49 3081.49 3116.38 1.00
AIRLOOP F6 SE DXAC HEAT PUMP 0.258712 0.258712 0.258712 0.258712 3993.20 3993.20 3115.91 1.00
AIRLOOP F6 NE DXAC HEAT PUMP 0.147099 0.147099 0.147099 0.147099 2335.57 2335.57 3117.55 1.00
AIRLOOP F6 N1 DXAC HEAT PUMP 0.094256 0.094256 0.094256 0.094256 1537.18 1537.18 2093.44 1.00
AIRLOOP F6 N2 DXAC HEAT PUMP 0.092048 0.092048 0.092048 0.092048 1503.94 1503.94 2093.47 1.00
AIRLOOP F6 S1 DXAC HEAT PUMP 0.210583 0.210583 0.210583 0.210583 3257.67 3257.67 2092.24 1.00
AIRLOOP F6 S2 DXAC HEAT PUMP 0.211608 0.211608 0.211608 0.211608 3272.10 3272.10 2092.27 1.00
AIRLOOP F7 SW DXAC HEAT PUMP 0.277696 0.277696 0.277696 0.277696 4265.64 4265.64 3186.83 1.00
AIRLOOP F7 NW DXAC HEAT PUMP 0.194923 0.194923 0.194923 0.194923 3063.90 3063.90 3188.27 1.00
AIRLOOP F7 SE DXAC HEAT PUMP 0.257078 0.257078 0.257078 0.257078 3978.07 3978.07 3188.57 1.00
AIRLOOP F7 NE DXAC HEAT PUMP 0.145319 0.145319 0.145319 0.145319 2316.23 2316.23 3190.01 1.00
AIRLOOP F7 N1 DXAC HEAT PUMP 0.093091 0.093091 0.093091 0.093091 1523.20 1523.20 2142.68 1.00
AIRLOOP F7 N2 DXAC HEAT PUMP 0.090893 0.090893 0.090893 0.090893 1490.01 1490.01 2142.73 1.00
AIRLOOP F7 S1 DXAC HEAT PUMP 0.209163 0.209163 0.209163 0.209163 3242.58 3242.58 2141.69 1.00
AIRLOOP F7 S2 DXAC HEAT PUMP 0.210188 0.210188 0.210188 0.210188 3257.02 3257.02 2141.74 1.00
AIRLOOP F8 SW DXAC HEAT PUMP 0.276837 0.276837 0.276837 0.276837 4260.80 4260.80 3261.15 1.00
AIRLOOP F8 NW DXAC HEAT PUMP 0.194203 0.194203 0.194203 0.194203 3059.92 3059.92 3262.16 1.00
AIRLOOP F8 SE DXAC HEAT PUMP 0.256373 0.256373 0.256373 0.256373 3975.22 3975.22 3263.40 1.00
AIRLOOP F8 NE DXAC HEAT PUMP 0.144497 0.144497 0.144497 0.144497 2309.84 2309.84 3264.41 1.00
AIRLOOP F8 N1 DXAC HEAT PUMP 0.092911 0.092911 0.092911 0.092911 1523.36 1523.36 2196.48 1.00
AIRLOOP F8 N2 DXAC HEAT PUMP 0.090724 0.090724 0.090724 0.090724 1490.25 1490.25 2196.54 1.00
AIRLOOP F8 S1 DXAC HEAT PUMP 0.208678 0.208678 0.208678 0.208678 3240.17 3240.17 2195.91 1.00
AIRLOOP F8 S2 DXAC HEAT PUMP 0.209705 0.209705 0.209705 0.209705 3254.64 3254.64 2195.96 1.00
AIRLOOP F9 SW DXAC HEAT PUMP 0.281657 0.281657 0.281657 0.281657 4335.87 4335.87 3449.99 1.00
AIRLOOP F9 NW DXAC HEAT PUMP 0.199302 0.199302 0.199302 0.199302 3138.96 3138.96 3448.43 1.00
AIRLOOP F9 SE DXAC HEAT PUMP 0.259841 0.259841 0.259841 0.259841 4033.47 4033.47 3452.73 1.00
AIRLOOP F9 NE DXAC HEAT PUMP 0.144096 0.144096 0.144096 0.144096 2309.30 2309.30 3451.16 1.00
AIRLOOP F9 N1 DXAC HEAT PUMP 0.097664 0.097664 0.097664 0.097664 1596.30 1596.30 2356.83 1.00
AIRLOOP F9 N2 DXAC HEAT PUMP 0.095452 0.095452 0.095452 0.095452 1562.89 1562.89 2356.90 1.00
AIRLOOP F9 S1 DXAC HEAT PUMP 0.211736 0.211736 0.211736 0.211736 3289.87 3289.87 2358.39 1.00
AIRLOOP F9 S2 DXAC HEAT PUMP 0.212766 0.212766 0.212766 0.212766 3304.39 3304.39 2358.46 1.00
AIRLOOP T SW DXAC HEAT PUMP 0.342443 0.342443 0.342443 0.342443 5209.30 5209.30 4058.25 1.00
AIRLOOP T NW DXAC HEAT PUMP 0.244016 0.244016 0.244016 0.244016 3789.16 3789.16 4063.02 1.00
AIRLOOP T SE DXAC HEAT PUMP 0.316108 0.316108 0.316108 0.316108 4834.41 4834.41 4061.13 1.00
AIRLOOP T NE DXAC HEAT PUMP 0.180179 0.180179 0.180179 0.180179 2848.36 2848.36 4065.90 1.00
AIRLOOP T N1 DXAC HEAT PUMP 0.128306 0.128306 0.128306 0.128306 2104.10 2104.10 3005.80 1.00
AIRLOOP T N2 DXAC HEAT PUMP 0.128475 0.128475 0.128475 0.128475 2106.64 2106.64 3005.87 1.00
AIRLOOP T S1 DXAC HEAT PUMP 0.278397 0.278397 0.278397 0.278397 4233.06 4233.06 2998.08 1.00
AIRLOOP T S2 DXAC HEAT PUMP 0.279401 0.279401 0.279401 0.279401 4247.16 4247.16 2998.16 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
AIRLOOP G SW SUPPLY FAN 0.215826
AIRLOOP G NW SUPPLY FAN 0.146618
AIRLOOP OFFICE SUPPLY FAN 0.337541
AIRLOOP G NE SUPPLY FAN 0.103519
AIRLOOP G N1 SUPPLY FAN 0.060532
AIRLOOP G N2 SUPPLY FAN 0.060528
AIRLOOP G S1 SUPPLY FAN 0.156552
AIRLOOP G S2 SUPPLY FAN 0.163111
AIRLOOP F2 SW SUPPLY FAN 0.280801
AIRLOOP F2 NW SUPPLY FAN 0.196086
AIRLOOP F2 SE SUPPLY FAN 0.282294
AIRLOOP F2 NE SUPPLY FAN 0.146185
AIRLOOP F2 N1 SUPPLY FAN 0.090309
AIRLOOP F2 N2 SUPPLY FAN 0.088098
AIRLOOP F2 S1 SUPPLY FAN 0.207860
AIRLOOP F2 S2 SUPPLY FAN 0.210404
AIRLOOP F3 SW SUPPLY FAN 0.282039
AIRLOOP F3 NW SUPPLY FAN 0.198623
AIRLOOP F3 SE SUPPLY FAN 0.262773
AIRLOOP F3 NE SUPPLY FAN 0.149341
AIRLOOP F3 N1 SUPPLY FAN 0.094253
AIRLOOP F3 N2 SUPPLY FAN 0.092031
AIRLOOP F3 S1 SUPPLY FAN 0.211281
AIRLOOP F3 S2 SUPPLY FAN 0.212521
AIRLOOP F4 SW SUPPLY FAN 0.281865
AIRLOOP F4 NW SUPPLY FAN 0.198732
AIRLOOP F4 SE SUPPLY FAN 0.260809
AIRLOOP F4 NE SUPPLY FAN 0.149324
AIRLOOP F4 N1 SUPPLY FAN 0.095106
AIRLOOP F4 N2 SUPPLY FAN 0.092883
AIRLOOP F4 S1 SUPPLY FAN 0.211879
AIRLOOP F4 S2 SUPPLY FAN 0.212933
AIRLOOP M SW SUPPLY FAN 0.283460
AIRLOOP M NW SUPPLY FAN 0.200480
AIRLOOP M SE SUPPLY FAN 0.262392
AIRLOOP M NE SUPPLY FAN 0.150917
AIRLOOP M N1 SUPPLY FAN 0.097309
AIRLOOP M N2 SUPPLY FAN 0.095084
AIRLOOP M S1 SUPPLY FAN 0.214031
AIRLOOP M S2 SUPPLY FAN 0.215057
AIRLOOP F6 SW SUPPLY FAN 0.279532
AIRLOOP F6 NW SUPPLY FAN 0.196653
AIRLOOP F6 SE SUPPLY FAN 0.258712
AIRLOOP F6 NE SUPPLY FAN 0.147099
AIRLOOP F6 N1 SUPPLY FAN 0.094256
AIRLOOP F6 N2 SUPPLY FAN 0.092048
AIRLOOP F6 S1 SUPPLY FAN 0.210583
AIRLOOP F6 S2 SUPPLY FAN 0.211608
AIRLOOP F7 SW SUPPLY FAN 0.277696
AIRLOOP F7 NW SUPPLY FAN 0.194923
AIRLOOP F7 SE SUPPLY FAN 0.257078
AIRLOOP F7 NE SUPPLY FAN 0.145319
AIRLOOP F7 N1 SUPPLY FAN 0.093091
AIRLOOP F7 N2 SUPPLY FAN 0.090893
AIRLOOP F7 S1 SUPPLY FAN 0.209163
AIRLOOP F7 S2 SUPPLY FAN 0.210188
AIRLOOP F8 SW SUPPLY FAN 0.276837
AIRLOOP F8 NW SUPPLY FAN 0.194203
AIRLOOP F8 SE SUPPLY FAN 0.256373
AIRLOOP F8 NE SUPPLY FAN 0.144497
AIRLOOP F8 N1 SUPPLY FAN 0.092911
AIRLOOP F8 N2 SUPPLY FAN 0.090724
AIRLOOP F8 S1 SUPPLY FAN 0.208678
AIRLOOP F8 S2 SUPPLY FAN 0.209705
AIRLOOP F9 SW SUPPLY FAN 0.281657
AIRLOOP F9 NW SUPPLY FAN 0.199302
AIRLOOP F9 SE SUPPLY FAN 0.259841
AIRLOOP F9 NE SUPPLY FAN 0.144096
AIRLOOP F9 N1 SUPPLY FAN 0.097664
AIRLOOP F9 N2 SUPPLY FAN 0.095452
AIRLOOP F9 S1 SUPPLY FAN 0.211736
AIRLOOP F9 S2 SUPPLY FAN 0.212766
AIRLOOP T SW SUPPLY FAN 0.342443
AIRLOOP T NW SUPPLY FAN 0.244016
AIRLOOP T SE SUPPLY FAN 0.316108
AIRLOOP T NE SUPPLY FAN 0.180179
AIRLOOP T N1 SUPPLY FAN 0.128306
AIRLOOP T N2 SUPPLY FAN 0.128475
AIRLOOP T S1 SUPPLY FAN 0.278397
AIRLOOP T S2 SUPPLY FAN 0.279401


COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Heating Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP HEATING MODE AIRLOOP G SW 0.215826 3301.54 0.000072
HEAT PUMP HEATING MODE AIRLOOP G NW 0.146618 2296.82 0.000050
HEAT PUMP HEATING MODE AIRLOOP OFFICE 0.337541 5084.36 0.000111
HEAT PUMP HEATING MODE AIRLOOP G NE 0.103519 1656.97 0.000036
HEAT PUMP HEATING MODE AIRLOOP G N1 0.060532 1012.32 0.000022
HEAT PUMP HEATING MODE AIRLOOP G N2 0.060528 1015.61 0.000022
HEAT PUMP HEATING MODE AIRLOOP G S1 0.156552 2446.12 0.000053
HEAT PUMP HEATING MODE AIRLOOP G S2 0.163111 2538.35 0.000055
HEAT PUMP HEATING MODE AIRLOOP F2 SW 0.280801 4248.57 0.000093
HEAT PUMP HEATING MODE AIRLOOP F2 NW 0.196086 3026.90 0.000066
HEAT PUMP HEATING MODE AIRLOOP F2 SE 0.282294 4274.09 0.000093
HEAT PUMP HEATING MODE AIRLOOP F2 NE 0.146185 2281.79 0.000050
HEAT PUMP HEATING MODE AIRLOOP F2 N1 0.090309 1458.60 0.000032
HEAT PUMP HEATING MODE AIRLOOP F2 N2 0.088098 1425.63 0.000031
HEAT PUMP HEATING MODE AIRLOOP F2 S1 0.207860 3187.56 0.000070
HEAT PUMP HEATING MODE AIRLOOP F2 S2 0.210404 3223.36 0.000070
HEAT PUMP HEATING MODE AIRLOOP F3 SW 0.282039 4284.54 0.000094
HEAT PUMP HEATING MODE AIRLOOP F3 NW 0.198623 3079.39 0.000067
HEAT PUMP HEATING MODE AIRLOOP F3 SE 0.262773 4017.07 0.000088
HEAT PUMP HEATING MODE AIRLOOP F3 NE 0.149341 2341.05 0.000051
HEAT PUMP HEATING MODE AIRLOOP F3 N1 0.094253 1523.54 0.000033
HEAT PUMP HEATING MODE AIRLOOP F3 N2 0.092031 1490.39 0.000033
HEAT PUMP HEATING MODE AIRLOOP F3 S1 0.211281 3246.84 0.000071
HEAT PUMP HEATING MODE AIRLOOP F3 S2 0.212521 3264.27 0.000071
HEAT PUMP HEATING MODE AIRLOOP F4 SW 0.281865 4295.85 0.000094
HEAT PUMP HEATING MODE AIRLOOP F4 NW 0.198732 3093.12 0.000068
HEAT PUMP HEATING MODE AIRLOOP F4 SE 0.260809 4002.79 0.000087
HEAT PUMP HEATING MODE AIRLOOP F4 NE 0.149324 2351.59 0.000051
HEAT PUMP HEATING MODE AIRLOOP F4 N1 0.095106 1541.54 0.000034
HEAT PUMP HEATING MODE AIRLOOP F4 N2 0.092883 1508.27 0.000033
HEAT PUMP HEATING MODE AIRLOOP F4 S1 0.211879 3263.55 0.000071
HEAT PUMP HEATING MODE AIRLOOP F4 S2 0.212933 3278.36 0.000072
HEAT PUMP HEATING MODE AIRLOOP M SW 0.283460 4329.52 0.000095
HEAT PUMP HEATING MODE AIRLOOP M NW 0.200480 3127.84 0.000068
HEAT PUMP HEATING MODE AIRLOOP M SE 0.262392 4036.10 0.000088
HEAT PUMP HEATING MODE AIRLOOP M NE 0.150917 2382.94 0.000052
HEAT PUMP HEATING MODE AIRLOOP M N1 0.097309 1578.24 0.000034
HEAT PUMP HEATING MODE AIRLOOP M N2 0.095084 1544.93 0.000034
HEAT PUMP HEATING MODE AIRLOOP M S1 0.214031 3300.66 0.000072
HEAT PUMP HEATING MODE AIRLOOP M S2 0.215057 3315.10 0.000072
HEAT PUMP HEATING MODE AIRLOOP F6 SW 0.279532 4283.41 0.000094
HEAT PUMP HEATING MODE AIRLOOP F6 NW 0.196653 3081.49 0.000067
HEAT PUMP HEATING MODE AIRLOOP F6 SE 0.258712 3993.20 0.000087
HEAT PUMP HEATING MODE AIRLOOP F6 NE 0.147099 2335.57 0.000051
HEAT PUMP HEATING MODE AIRLOOP F6 N1 0.094256 1537.18 0.000034
HEAT PUMP HEATING MODE AIRLOOP F6 N2 0.092048 1503.94 0.000033
HEAT PUMP HEATING MODE AIRLOOP F6 S1 0.210583 3257.67 0.000071
HEAT PUMP HEATING MODE AIRLOOP F6 S2 0.211608 3272.10 0.000071
HEAT PUMP HEATING MODE AIRLOOP F7 SW 0.277696 4265.64 0.000093
HEAT PUMP HEATING MODE AIRLOOP F7 NW 0.194923 3063.90 0.000067
HEAT PUMP HEATING MODE AIRLOOP F7 SE 0.257078 3978.07 0.000087
HEAT PUMP HEATING MODE AIRLOOP F7 NE 0.145319 2316.23 0.000051
HEAT PUMP HEATING MODE AIRLOOP F7 N1 0.093091 1523.20 0.000033
HEAT PUMP HEATING MODE AIRLOOP F7 N2 0.090893 1490.01 0.000033
HEAT PUMP HEATING MODE AIRLOOP F7 S1 0.209163 3242.58 0.000071
HEAT PUMP HEATING MODE AIRLOOP F7 S2 0.210188 3257.02 0.000071
HEAT PUMP HEATING MODE AIRLOOP F8 SW 0.276837 4260.80 0.000093
HEAT PUMP HEATING MODE AIRLOOP F8 NW 0.194203 3059.92 0.000067
HEAT PUMP HEATING MODE AIRLOOP F8 SE 0.256373 3975.22 0.000087
HEAT PUMP HEATING MODE AIRLOOP F8 NE 0.144497 2309.84 0.000050
HEAT PUMP HEATING MODE AIRLOOP F8 N1 0.092911 1523.36 0.000033
HEAT PUMP HEATING MODE AIRLOOP F8 N2 0.090724 1490.25 0.000033
HEAT PUMP HEATING MODE AIRLOOP F8 S1 0.208678 3240.17 0.000071
HEAT PUMP HEATING MODE AIRLOOP F8 S2 0.209705 3254.64 0.000071
HEAT PUMP HEATING MODE AIRLOOP F9 SW 0.281657 4335.87 0.000095
HEAT PUMP HEATING MODE AIRLOOP F9 NW 0.199302 3138.96 0.000069
HEAT PUMP HEATING MODE AIRLOOP F9 SE 0.259841 4033.47 0.000088
HEAT PUMP HEATING MODE AIRLOOP F9 NE 0.144096 2309.30 0.000050
HEAT PUMP HEATING MODE AIRLOOP F9 N1 0.097664 1596.30 0.000035
HEAT PUMP HEATING MODE AIRLOOP F9 N2 0.095452 1562.89 0.000034
HEAT PUMP HEATING MODE AIRLOOP F9 S1 0.211736 3289.87 0.000072
HEAT PUMP HEATING MODE AIRLOOP F9 S2 0.212766 3304.39 0.000072
HEAT PUMP HEATING MODE AIRLOOP T SW 0.342443 5209.30 0.000114
HEAT PUMP HEATING MODE AIRLOOP T NW 0.244016 3789.16 0.000083
HEAT PUMP HEATING MODE AIRLOOP T SE 0.316108 4834.41 0.000106
HEAT PUMP HEATING MODE AIRLOOP T NE 0.180179 2848.36 0.000062
HEAT PUMP HEATING MODE AIRLOOP T N1 0.128306 2104.10 0.000046
HEAT PUMP HEATING MODE AIRLOOP T N2 0.128475 2106.64 0.000046
HEAT PUMP HEATING MODE AIRLOOP T S1 0.278397 4233.06 0.000092
HEAT PUMP HEATING MODE AIRLOOP T S2 0.279401 4247.16 0.000093


Coil:Heating:Electric

Nominal Capacity [W]
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW 2947.58
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW 2952.99
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE 3720.93
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE 2949.94
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 2241.39
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 2241.32
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 2232.33
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 2238.56
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW 2880.32
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW 2880.67
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE 2896.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE 2878.42
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 1997.40
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 1997.35
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 1999.80
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 2000.97
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW 2901.57
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW 2902.68
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE 2902.50
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE 2901.54
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 1973.08
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 1973.05
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 1972.75
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 1972.92
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW 2969.72
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW 2971.33
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE 2969.70
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE 2971.09
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 2004.57
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 2004.56
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 2003.47
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 2003.49
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW 3015.16
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW 3015.94
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE 3015.70
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE 3016.46
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 2020.36
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 2020.37
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 2020.04
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 2020.06
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW 3114.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW 3116.38
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE 3115.91
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE 3117.55
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 2093.44
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 2093.47
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 2092.24
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 2092.27
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW 3186.83
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW 3188.27
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE 3188.57
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE 3190.01
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 2142.68
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 2142.73
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 2141.69
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 2141.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW 3261.15
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW 3262.16
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE 3263.40
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE 3264.41
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 2196.48
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 2196.54
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 2195.91
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 2195.96
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW 3449.99
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW 3448.43
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE 3452.73
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE 3451.16
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 2356.83
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 2356.90
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 2358.39
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 2358.46
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW 4058.25
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW 4063.02
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE 4061.13
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE 4065.90
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 3005.80
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 3005.87
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 2998.08
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 2998.16


PlantLoop

Maximum Loop Flow Rate [m3/s] Plant Loop Volume [m3]
SHWSYS1 0.000289 0.325214
SINGLE WATER PLANT LOOP 0.005136 5.78


Boiler:HotWater

Design Water Flow Rate [m3/s]
CENTRAL BOILER 0.005136


WaterHeater:Mixed

Use Side Design Flow Rate [m3/s]
SHWSYS1 WATER HEATER 0.000289


EvaporativeFluidCooler:SingleSpeed

Design Water Flow Rate [m3/s] Fan Power at Design Air Flow Rate [W] Design Air Flow Rate [m3/s] U-Factor Times Area Value at Design Air Flow Rate [W/C]
CENTRAL TOWER 0.005136 2479.57 6.53 7693.53


Pump:ConstantSpeed

Rated Flow Rate [m3/s] Rated Power Consumption [W]
SHWSYS1 PUMP 0.000289 36.93
PLANT CIRC PUMP 0.005136 1640.30



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:21

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW3 |
G WWALL SWA GWINDOW2 |
G NWALL NWA GWINDOW4 |
G WWALL NWA GWINDOW6 |
G SWALL SEA GWINDOW1 |
G EWALL SEA GWINDOW8 |
G NWALL NEA GWINDOW5 |
G EWALL NEA GWINDOW7 |
G NWALL N1A GWINDOW9 |
G NWALL N2A GWINDOW10 |
G SWALL S1A GWINDOW11 |
G SWALL S2A GWINDOW12 |
G WWALL C GWINDOW13 |
G EWALL C ENTRANCE DOOR |
F2 WWALL SWA F2WINDOW2 |
F2 SWALL SWA F2WINDOW3 |
F2 NWALL NWA F2WINDOW4 |
F2 WWALL NWA F2WINDOW6 |
F2 EWALL SEA F2WINDOW8 |
F2 SWALL SEA F2WINDOW1 |
F2 NWALL NEA F2WINDOW5 |
F2 EWALL NEA F2WINDOW7 |
F2 NWALL N1A F2WINDOW9 |
F2 NWALL N2A F2WINDOW10 |
F2 SWALL S1A F2WINDOW11 |
F2 SWALL S2A F2WINDOW12 |
F2 WWALL C F2WINDOW13 |
F2 EWALL C F2WINDOW14 |
F3 WWALL SWA F3WINDOW2 |
F3 SWALL SWA F3WINDOW3 |
F3 NWALL NWA F3WINDOW4 |
F3 WWALL NWA F3WINDOW6 |
F3 EWALL SEA F3WINDOW8 |
F3 SWALL SEA F3WINDOW1 |
F3 NWALL NEA F3WINDOW5 |
F3 EWALL NEA F3WINDOW7 |
F3 NWALL N1A F3WINDOW9 |
F3 NWALL N2A F3WINDOW10 |
F3 SWALL S1A F3WINDOW11 |
F3 SWALL S2A F3WINDOW12 |
F3 WWALL C F3WINDOW13 |
F3 EWALL C F3WINDOW14 |
F4 WWALL SWA F4WINDOW2 |
F4 SWALL SWA F4WINDOW3 |
F4 NWALL NWA F4WINDOW4 |
F4 WWALL NWA F4WINDOW6 |
F4 EWALL SEA F4WINDOW8 |
F4 SWALL SEA F4WINDOW1 |
F4 NWALL NEA F4WINDOW5 |
F4 EWALL NEA F4WINDOW7 |
F4 NWALL N1A F4WINDOW9 |
F4 NWALL N2A F4WINDOW10 |
F4 SWALL S1A F4WINDOW11 |
F4 SWALL S2A F4WINDOW12 |
F4 WWALL C F4WINDOW13 |
F4 EWALL C F4WINDOW14 |
M WWALL SWA MWINDOW2 |
M SWALL SWA MWINDOW3 |
M NWALL NWA MWINDOW4 |
M WWALL NWA MWINDOW6 |
M EWALL SEA MWINDOW8 |
M SWALL SEA MWINDOW1 |
M NWALL NEA MWINDOW5 |
M EWALL NEA MWINDOW7 |
M NWALL N1A MWINDOW9 |
M NWALL N2A MWINDOW10 |
M SWALL S1A MWINDOW11 |
M SWALL S2A MWINDOW12 |
M WWALL C MWINDOW13 |
M EWALL C MWINDOW14 |
F6 WWALL SWA F6WINDOW2 |
F6 SWALL SWA F6WINDOW3 |
F6 NWALL NWA F6WINDOW4 |
F6 WWALL NWA F6WINDOW6 |
F6 EWALL SEA F6WINDOW8 |
F6 SWALL SEA F6WINDOW1 |
F6 NWALL NEA F6WINDOW5 |
F6 EWALL NEA F6WINDOW7 |
F6 NWALL N1A F6WINDOW9 |
F6 NWALL N2A F6WINDOW10 |
F6 SWALL S1A F6WINDOW11 |
F6 SWALL S2A F6WINDOW12 |
F6 WWALL C F6WINDOW13 |
F6 EWALL C F6WINDOW14 |
F7 WWALL SWA F7WINDOW2 |
F7 SWALL SWA F7WINDOW3 |
F7 NWALL NWA F7WINDOW4 |
F7 WWALL NWA F7WINDOW6 |
F7 EWALL SEA F7WINDOW8 |
F7 SWALL SEA F7WINDOW1 |
F7 NWALL NEA F7WINDOW5 |
F7 EWALL NEA F7WINDOW7 |
F7 NWALL N1A F7WINDOW9 |
F7 NWALL N2A F7WINDOW10 |
F7 SWALL S1A F7WINDOW11 |
F7 SWALL S2A F7WINDOW12 |
F7 WWALL C F7WINDOW13 |
F7 EWALL C F7WINDOW14 |
F8 WWALL SWA F8WINDOW2 |
F8 SWALL SWA F8WINDOW3 |
F8 NWALL NWA F8WINDOW4 |
F8 WWALL NWA F8WINDOW6 |
F8 EWALL SEA F8WINDOW8 |
F8 SWALL SEA F8WINDOW1 |
F8 NWALL NEA F8WINDOW5 |
F8 EWALL NEA F8WINDOW7 |
F8 NWALL N1A F8WINDOW9 |
F8 NWALL N2A F8WINDOW10 |
F8 SWALL S1A F8WINDOW11 |
F8 SWALL S2A F8WINDOW12 |
F8 WWALL C F8WINDOW13 |
F8 EWALL C F8WINDOW14 |
F9 WWALL SWA F9WINDOW2 |
F9 SWALL SWA F9WINDOW3 |
F9 NWALL NWA F9WINDOW4 |
F9 WWALL NWA F9WINDOW6 |
F9 EWALL SEA F9WINDOW8 |
F9 SWALL SEA F9WINDOW1 |
F9 NWALL NEA F9WINDOW5 |
F9 EWALL NEA F9WINDOW7 |
F9 NWALL N1A F9WINDOW9 |
F9 NWALL N2A F9WINDOW10 |
F9 SWALL S1A F9WINDOW11 |
F9 SWALL S2A F9WINDOW12 |
F9 WWALL C F9WINDOW13 |
F9 EWALL C F9WINDOW14 |
T WWALL SWA TWINDOW2 |
T SWALL SWA TWINDOW3 |
T NWALL NWA TWINDOW4 |
T WWALL NWA TWINDOW6 |
T EWALL SEA TWINDOW8 |
T SWALL SEA TWINDOW1 |
T NWALL NEA TWINDOW5 |
T EWALL NEA TWINDOW7 |
T NWALL N1A TWINDOW9 |
T NWALL N2A TWINDOW10 |
T SWALL S1A TWINDOW11 |
T SWALL S2A TWINDOW12 |
T WWALL C TWINDOW13 |
T EWALL C TWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:21

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 3.20
February 21.92 5.10
March 22.09 6.09
April 22.52 8.68
May 23.00 11.83
June 23.69 15.06
July 24.02 16.98
August 23.95 17.08
September 23.58 13.78
October 22.28 9.83
November 21.81 5.28
December 21.72 3.63
     
Annual Sum or Average 22.70 9.74
Minimum of Months 21.71 3.20
Maximum of Months 24.02 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.76 6.09
April 21.93 8.68
May 22.44 11.83
June 23.40 15.06
July 23.84 16.98
August 23.64 17.08
September 22.87 13.78
October 21.80 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.38 9.74
Minimum of Months 21.70 3.20
Maximum of Months 23.84 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.83 3.20
February 22.17 5.10
March 22.37 6.09
April 22.76 8.68
May 23.32 11.83
June 24.14 15.06
July 24.32 16.98
August 24.35 17.08
September 23.94 13.78
October 22.57 9.83
November 22.06 5.28
December 21.84 3.63
     
Annual Sum or Average 22.98 9.74
Minimum of Months 21.83 3.20
Maximum of Months 24.35 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.72 6.09
April 21.84 8.68
May 22.27 11.83
June 23.21 15.06
July 23.75 16.98
August 23.57 17.08
September 22.73 13.78
October 21.78 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.31 9.74
Minimum of Months 21.70 3.20
Maximum of Months 23.75 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.71 6.09
April 21.76 8.68
May 22.06 11.83
June 23.05 15.06
July 23.59 16.98
August 23.39 17.08
September 22.66 13.78
October 21.76 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.24 9.74
Minimum of Months 21.70 3.20
Maximum of Months 23.59 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.71 6.09
April 21.75 8.68
May 22.05 11.83
June 23.04 15.06
July 23.58 16.98
August 23.38 17.08
September 22.64 13.78
October 21.76 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.23 9.74
Minimum of Months 21.70 3.20
Maximum of Months 23.58 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.72 3.20
February 21.94 5.10
March 22.09 6.09
April 22.48 8.68
May 22.88 11.83
June 23.58 15.06
July 23.97 16.98
August 23.94 17.08
September 23.70 13.78
October 22.43 9.83
November 21.84 5.28
December 21.74 3.63
     
Annual Sum or Average 22.70 9.74
Minimum of Months 21.72 3.20
Maximum of Months 23.97 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 3.20
February 21.96 5.10
March 22.13 6.09
April 22.52 8.68
May 22.95 11.83
June 23.64 15.06
July 24.00 16.98
August 23.98 17.08
September 23.75 13.78
October 22.48 9.83
November 21.85 5.28
December 21.74 3.63
     
Annual Sum or Average 22.73 9.74
Minimum of Months 21.73 3.20
Maximum of Months 24.00 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 16.15 3.20
February 17.01 5.10
March 17.49 6.09
April 18.72 8.68
May 20.12 11.83
June 22.04 15.06
July 23.10 16.98
August 22.93 17.08
September 21.49 13.78
October 18.80 9.83
November 16.94 5.28
December 16.20 3.63
     
Annual Sum or Average 19.26 9.74
Minimum of Months 16.15 3.20
Maximum of Months 23.10 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SW APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.74 3.20
February 22.15 5.10
March 22.46 6.09
April 23.20 8.68
May 23.85 11.83
June 24.12 15.06
July 24.24 16.98
August 24.17 17.08
September 23.88 13.78
October 22.72 9.83
November 21.94 5.28
December 21.74 3.63
     
Annual Sum or Average 23.02 9.74
Minimum of Months 21.74 3.20
Maximum of Months 24.24 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NW APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.88 6.09
April 22.24 8.68
May 23.31 11.83
June 23.90 15.06
July 24.15 16.98
August 23.97 17.08
September 23.16 13.78
October 21.94 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.62 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.15 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SE APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.75 3.20
February 22.22 5.10
March 22.52 6.09
April 23.24 8.68
May 23.92 11.83
June 24.18 15.06
July 24.30 16.98
August 24.25 17.08
September 23.97 13.78
October 22.84 9.83
November 21.99 5.28
December 21.76 3.63
     
Annual Sum or Average 23.08 9.74
Minimum of Months 21.75 3.20
Maximum of Months 24.30 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NE APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.82 6.09
April 22.12 8.68
May 23.12 11.83
June 23.74 15.06
July 24.11 16.98
August 23.92 17.08
September 22.99 13.78
October 21.92 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.55 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.11 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N1 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.81 6.09
April 21.98 8.68
May 22.95 11.83
June 23.62 15.06
July 23.99 16.98
August 23.78 17.08
September 22.92 13.78
October 21.94 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.49 9.74
Minimum of Months 21.70 3.20
Maximum of Months 23.99 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N2 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.80 6.09
April 21.97 8.68
May 22.92 11.83
June 23.60 15.06
July 23.98 16.98
August 23.77 17.08
September 22.89 13.78
October 21.94 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.48 9.74
Minimum of Months 21.70 3.20
Maximum of Months 23.98 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S1 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.78 3.20
February 22.35 5.10
March 22.56 6.09
April 23.32 8.68
May 23.91 11.83
June 24.05 15.06
July 24.20 16.98
August 24.15 17.08
September 24.00 13.78
October 23.04 9.83
November 22.06 5.28
December 21.79 3.63
     
Annual Sum or Average 23.11 9.74
Minimum of Months 21.78 3.20
Maximum of Months 24.20 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S2 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.78 3.20
February 22.36 5.10
March 22.57 6.09
April 23.33 8.68
May 23.93 11.83
June 24.06 15.06
July 24.21 16.98
August 24.16 17.08
September 24.02 13.78
October 23.07 9.83
November 22.07 5.28
December 21.79 3.63
     
Annual Sum or Average 23.12 9.74
Minimum of Months 21.78 3.20
Maximum of Months 24.21 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 CORRIDOR

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.30 3.20
February 22.00 5.10
March 22.29 6.09
April 23.31 8.68
May 24.40 11.83
June 25.26 15.06
July 25.76 16.98
August 25.55 17.08
September 24.65 13.78
October 22.82 9.83
November 21.67 5.28
December 21.20 3.63
     
Annual Sum or Average 23.36 9.74
Minimum of Months 21.20 3.20
Maximum of Months 25.76 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SW APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.74 3.20
February 22.22 5.10
March 22.53 6.09
April 23.33 8.68
May 23.96 11.83
June 24.15 15.06
July 24.24 16.98
August 24.17 17.08
September 23.88 13.78
October 22.79 9.83
November 21.97 5.28
December 21.74 3.63
     
Annual Sum or Average 23.06 9.74
Minimum of Months 21.74 3.20
Maximum of Months 24.24 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NW APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.71 5.10
March 21.93 6.09
April 22.33 8.68
May 23.51 11.83
June 23.95 15.06
July 24.17 16.98
August 23.98 17.08
September 23.18 13.78
October 21.99 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.66 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.17 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SE APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.74 3.20
February 22.19 5.10
March 22.50 6.09
April 23.25 8.68
May 23.94 11.83
June 24.13 15.06
July 24.27 16.98
August 24.20 17.08
September 23.89 13.78
October 22.81 9.83
November 21.97 5.28
December 21.74 3.63
     
Annual Sum or Average 23.06 9.74
Minimum of Months 21.74 3.20
Maximum of Months 24.27 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NE APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.86 6.09
April 22.20 8.68
May 23.33 11.83
June 23.82 15.06
July 24.14 16.98
August 23.94 17.08
September 23.00 13.78
October 21.97 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.59 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.14 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N1 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.87 6.09
April 22.10 8.68
May 23.29 11.83
June 23.74 15.06
July 24.04 16.98
August 23.82 17.08
September 22.97 13.78
October 22.03 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.56 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.04 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N2 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.86 6.09
April 22.08 8.68
May 23.26 11.83
June 23.72 15.06
July 24.04 16.98
August 23.81 17.08
September 22.95 13.78
October 22.03 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.55 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.04 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S1 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.80 3.20
February 22.52 5.10
March 22.68 6.09
April 23.53 8.68
May 24.08 11.83
June 24.10 15.06
July 24.21 16.98
August 24.16 17.08
September 24.02 13.78
October 23.20 9.83
November 22.14 5.28
December 21.80 3.63
     
Annual Sum or Average 23.19 9.74
Minimum of Months 21.80 3.20
Maximum of Months 24.21 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S2 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.80 3.20
February 22.52 5.10
March 22.68 6.09
April 23.52 8.68
May 24.09 11.83
June 24.10 15.06
July 24.21 16.98
August 24.16 17.08
September 24.02 13.78
October 23.21 9.83
November 22.14 5.28
December 21.80 3.63
     
Annual Sum or Average 23.19 9.74
Minimum of Months 21.80 3.20
Maximum of Months 24.21 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 CORRIDOR

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.75 3.20
February 22.49 5.10
March 22.76 6.09
April 23.83 8.68
May 24.98 11.83
June 25.59 15.06
July 26.00 16.98
August 25.76 17.08
September 24.90 13.78
October 23.22 9.83
November 22.10 5.28
December 21.61 3.63
     
Annual Sum or Average 23.76 9.74
Minimum of Months 21.61 3.20
Maximum of Months 26.00 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SW APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.74 3.20
February 22.22 5.10
March 22.54 6.09
April 23.33 8.68
May 23.96 11.83
June 24.17 15.06
July 24.25 16.98
August 24.16 17.08
September 23.92 13.78
October 22.78 9.83
November 21.98 5.28
December 21.74 3.63
     
Annual Sum or Average 23.07 9.74
Minimum of Months 21.74 3.20
Maximum of Months 24.25 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NW APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.71 5.10
March 21.95 6.09
April 22.34 8.68
May 23.54 11.83
June 24.00 15.06
July 24.18 16.98
August 23.97 17.08
September 23.23 13.78
October 21.99 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.67 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.18 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SE APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.74 3.20
February 22.17 5.10
March 22.50 6.09
April 23.23 8.68
May 23.93 11.83
June 24.13 15.06
July 24.28 16.98
August 24.18 17.08
September 23.90 13.78
October 22.78 9.83
November 21.96 5.28
December 21.74 3.63
     
Annual Sum or Average 23.05 9.74
Minimum of Months 21.74 3.20
Maximum of Months 24.28 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NE APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.87 6.09
April 22.21 8.68
May 23.39 11.83
June 23.87 15.06
July 24.15 16.98
August 23.92 17.08
September 23.05 13.78
October 21.97 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.61 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.15 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N1 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.90 6.09
April 22.14 8.68
May 23.41 11.83
June 23.83 15.06
July 24.07 16.98
August 23.81 17.08
September 23.07 13.78
October 22.05 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.60 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.07 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N2 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.89 6.09
April 22.13 8.68
May 23.38 11.83
June 23.81 15.06
July 24.07 16.98
August 23.80 17.08
September 23.04 13.78
October 22.05 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.59 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.07 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S1 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.80 3.20
February 22.55 5.10
March 22.70 6.09
April 23.56 8.68
May 24.11 11.83
June 24.14 15.06
July 24.23 16.98
August 24.15 17.08
September 24.07 13.78
October 23.22 9.83
November 22.16 5.28
December 21.80 3.63
     
Annual Sum or Average 23.21 9.74
Minimum of Months 21.80 3.20
Maximum of Months 24.23 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S2 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.80 3.20
February 22.55 5.10
March 22.70 6.09
April 23.55 8.68
May 24.11 11.83
June 24.14 15.06
July 24.23 16.98
August 24.15 17.08
September 24.07 13.78
October 23.23 9.83
November 22.16 5.28
December 21.80 3.63
     
Annual Sum or Average 23.21 9.74
Minimum of Months 21.80 3.20
Maximum of Months 24.23 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 CORRIDOR

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.89 3.20
February 22.64 5.10
March 22.91 6.09
April 23.99 8.68
May 25.17 11.83
June 25.73 15.06
July 26.11 16.98
August 25.84 17.08
September 25.03 13.78
October 23.36 9.83
November 22.23 5.28
December 21.73 3.63
     
Annual Sum or Average 23.89 9.74
Minimum of Months 21.73 3.20
Maximum of Months 26.11 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.75 3.20
February 22.22 5.10
March 22.54 6.09
April 23.31 8.68
May 23.94 11.83
June 24.16 15.06
July 24.25 16.98
August 24.15 17.08
September 23.90 13.78
October 22.76 9.83
November 21.98 5.28
December 21.74 3.63
     
Annual Sum or Average 23.06 9.74
Minimum of Months 21.74 3.20
Maximum of Months 24.25 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.71 5.10
March 21.95 6.09
April 22.34 8.68
May 23.53 11.83
June 23.98 15.06
July 24.17 16.98
August 23.95 17.08
September 23.21 13.78
October 21.99 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.67 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.17 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.74 3.20
February 22.17 5.10
March 22.49 6.09
April 23.21 8.68
May 23.91 11.83
June 24.12 15.06
July 24.27 16.98
August 24.17 17.08
September 23.88 13.78
October 22.76 9.83
November 21.96 5.28
December 21.74 3.63
     
Annual Sum or Average 23.04 9.74
Minimum of Months 21.74 3.20
Maximum of Months 24.27 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.88 6.09
April 22.20 8.68
May 23.38 11.83
June 23.86 15.06
July 24.15 16.98
August 23.90 17.08
September 23.03 13.78
October 21.97 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.60 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.15 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.91 6.09
April 22.16 8.68
May 23.43 11.83
June 23.83 15.06
July 24.07 16.98
August 23.80 17.08
September 23.08 13.78
October 22.07 9.83
November 21.71 5.28
December 21.70 3.63
     
Annual Sum or Average 22.60 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.07 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.90 6.09
April 22.14 8.68
May 23.41 11.83
June 23.82 15.06
July 24.07 16.98
August 23.79 17.08
September 23.05 13.78
October 22.07 9.83
November 21.71 5.28
December 21.70 3.63
     
Annual Sum or Average 22.59 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.07 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.81 3.20
February 22.57 5.10
March 22.70 6.09
April 23.57 8.68
May 24.11 11.83
June 24.14 15.06
July 24.22 16.98
August 24.14 17.08
September 24.06 13.78
October 23.22 9.83
November 22.17 5.28
December 21.80 3.63
     
Annual Sum or Average 23.21 9.74
Minimum of Months 21.80 3.20
Maximum of Months 24.22 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.81 3.20
February 22.57 5.10
March 22.70 6.09
April 23.55 8.68
May 24.11 11.83
June 24.14 15.06
July 24.22 16.98
August 24.14 17.08
September 24.06 13.78
October 23.22 9.83
November 22.17 5.28
December 21.80 3.63
     
Annual Sum or Average 23.21 9.74
Minimum of Months 21.80 3.20
Maximum of Months 24.22 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.49 3.20
February 23.23 5.10
March 23.50 6.09
April 24.55 8.68
May 25.73 11.83
June 26.27 15.06
July 26.64 16.98
August 26.37 17.08
September 25.57 13.78
October 23.93 9.83
November 22.83 5.28
December 22.32 3.63
     
Annual Sum or Average 24.46 9.74
Minimum of Months 22.32 3.20
Maximum of Months 26.64 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SW APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.74 3.20
February 22.17 5.10
March 22.49 6.09
April 23.23 8.68
May 23.87 11.83
June 24.11 15.06
July 24.22 16.98
August 24.11 17.08
September 23.84 13.78
October 22.69 9.83
November 21.96 5.28
December 21.73 3.63
     
Annual Sum or Average 23.02 9.74
Minimum of Months 21.73 3.20
Maximum of Months 24.22 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NW APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.71 5.10
March 21.92 6.09
April 22.25 8.68
May 23.42 11.83
June 23.90 15.06
July 24.13 16.98
August 23.87 17.08
September 23.08 13.78
October 21.94 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.62 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.13 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SE APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.74 3.20
February 22.12 5.10
March 22.45 6.09
April 23.13 8.68
May 23.84 11.83
June 24.05 15.06
July 24.24 16.98
August 24.12 17.08
September 23.81 13.78
October 22.68 9.83
November 21.94 5.28
December 21.73 3.63
     
Annual Sum or Average 22.99 9.74
Minimum of Months 21.73 3.20
Maximum of Months 24.24 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NE APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.85 6.09
April 22.14 8.68
May 23.27 11.83
June 23.76 15.06
July 24.09 16.98
August 23.81 17.08
September 22.91 13.78
October 21.93 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.55 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.09 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N1 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.88 6.09
April 22.08 8.68
May 23.30 11.83
June 23.74 15.06
July 24.01 16.98
August 23.71 17.08
September 22.95 13.78
October 22.01 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.55 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.01 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N2 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.87 6.09
April 22.07 8.68
May 23.28 11.83
June 23.72 15.06
July 24.00 16.98
August 23.70 17.08
September 22.92 13.78
October 22.01 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.54 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.00 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S1 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.79 3.20
February 22.49 5.10
March 22.66 6.09
April 23.48 8.68
May 24.05 11.83
June 24.09 15.06
July 24.19 16.98
August 24.10 17.08
September 24.00 13.78
October 23.12 9.83
November 22.13 5.28
December 21.78 3.63
     
Annual Sum or Average 23.16 9.74
Minimum of Months 21.78 3.20
Maximum of Months 24.19 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S2 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.79 3.20
February 22.49 5.10
March 22.65 6.09
April 23.47 8.68
May 24.05 11.83
June 24.08 15.06
July 24.19 16.98
August 24.10 17.08
September 24.00 13.78
October 23.12 9.83
November 22.13 5.28
December 21.78 3.63
     
Annual Sum or Average 23.16 9.74
Minimum of Months 21.78 3.20
Maximum of Months 24.19 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 CORRIDOR

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.86 3.20
February 22.60 5.10
March 22.86 6.09
April 23.91 8.68
May 25.08 11.83
June 25.64 15.06
July 26.05 16.98
August 25.75 17.08
September 24.92 13.78
October 23.28 9.83
November 22.19 5.28
December 21.68 3.63
     
Annual Sum or Average 23.83 9.74
Minimum of Months 21.68 3.20
Maximum of Months 26.05 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SW APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.74 3.20
February 22.13 5.10
March 22.46 6.09
April 23.16 8.68
May 23.82 11.83
June 24.07 15.06
July 24.20 16.98
August 24.07 17.08
September 23.78 13.78
October 22.63 9.83
November 21.94 5.28
December 21.73 3.63
     
Annual Sum or Average 22.98 9.74
Minimum of Months 21.73 3.20
Maximum of Months 24.20 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NW APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.89 6.09
April 22.20 8.68
May 23.34 11.83
June 23.84 15.06
July 24.10 16.98
August 23.81 17.08
September 22.98 13.78
October 21.91 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.58 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.10 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SE APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 3.20
February 22.09 5.10
March 22.42 6.09
April 23.07 8.68
May 23.77 11.83
June 24.01 15.06
July 24.22 16.98
August 24.08 17.08
September 23.75 13.78
October 22.63 9.83
November 21.93 5.28
December 21.72 3.63
     
Annual Sum or Average 22.96 9.74
Minimum of Months 21.72 3.20
Maximum of Months 24.22 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NE APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.83 6.09
April 22.09 8.68
May 23.18 11.83
June 23.69 15.06
July 24.04 16.98
August 23.73 17.08
September 22.81 13.78
October 21.90 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.51 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.04 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N1 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.86 6.09
April 22.03 8.68
May 23.20 11.83
June 23.67 15.06
July 23.97 16.98
August 23.63 17.08
September 22.85 13.78
October 21.96 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.50 9.74
Minimum of Months 21.70 3.20
Maximum of Months 23.97 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N2 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.85 6.09
April 22.02 8.68
May 23.17 11.83
June 23.64 15.06
July 23.95 16.98
August 23.62 17.08
September 22.82 13.78
October 21.96 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.49 9.74
Minimum of Months 21.70 3.20
Maximum of Months 23.95 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S1 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.78 3.20
February 22.43 5.10
March 22.62 6.09
April 23.41 8.68
May 24.00 11.83
June 24.04 15.06
July 24.17 16.98
August 24.07 17.08
September 23.95 13.78
October 23.03 9.83
November 22.10 5.28
December 21.77 3.63
     
Annual Sum or Average 23.12 9.74
Minimum of Months 21.77 3.20
Maximum of Months 24.17 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S2 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.78 3.20
February 22.43 5.10
March 22.62 6.09
April 23.40 8.68
May 24.00 11.83
June 24.04 15.06
July 24.18 16.98
August 24.07 17.08
September 23.94 13.78
October 23.04 9.83
November 22.10 5.28
December 21.77 3.63
     
Annual Sum or Average 23.12 9.74
Minimum of Months 21.77 3.20
Maximum of Months 24.18 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 CORRIDOR

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 3.20
February 22.46 5.10
March 22.72 6.09
April 23.74 8.68
May 24.91 11.83
June 25.49 15.06
July 25.93 16.98
August 25.61 17.08
September 24.75 13.78
October 23.12 9.83
November 22.06 5.28
December 21.55 3.63
     
Annual Sum or Average 23.68 9.74
Minimum of Months 21.55 3.20
Maximum of Months 25.93 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SW APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 3.20
February 22.10 5.10
March 22.43 6.09
April 23.10 8.68
May 23.77 11.83
June 24.02 15.06
July 24.18 16.98
August 24.04 17.08
September 23.73 13.78
October 22.58 9.83
November 21.92 5.28
December 21.72 3.63
     
Annual Sum or Average 22.95 9.74
Minimum of Months 21.72 3.20
Maximum of Months 24.18 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NW APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.87 6.09
April 22.16 8.68
May 23.26 11.83
June 23.78 15.06
July 24.07 16.98
August 23.76 17.08
September 22.90 13.78
October 21.88 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.55 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.07 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SE APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 3.20
February 22.06 5.10
March 22.39 6.09
April 23.01 8.68
May 23.71 11.83
June 23.96 15.06
July 24.19 16.98
August 24.05 17.08
September 23.70 13.78
October 22.58 9.83
November 21.91 5.28
December 21.72 3.63
     
Annual Sum or Average 22.92 9.74
Minimum of Months 21.72 3.20
Maximum of Months 24.19 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NE APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.82 6.09
April 22.06 8.68
May 23.10 11.83
June 23.62 15.06
July 23.99 16.98
August 23.67 17.08
September 22.73 13.78
October 21.87 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.48 9.74
Minimum of Months 21.70 3.20
Maximum of Months 23.99 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N1 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.84 6.09
April 21.99 8.68
May 23.11 11.83
June 23.60 15.06
July 23.92 16.98
August 23.57 17.08
September 22.76 13.78
October 21.93 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.47 9.74
Minimum of Months 21.70 3.20
Maximum of Months 23.92 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N2 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.83 6.09
April 21.98 8.68
May 23.09 11.83
June 23.58 15.06
July 23.91 16.98
August 23.55 17.08
September 22.74 13.78
October 21.93 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.46 9.74
Minimum of Months 21.70 3.20
Maximum of Months 23.91 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S1 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.77 3.20
February 22.36 5.10
March 22.58 6.09
April 23.34 8.68
May 23.95 11.83
June 24.00 15.06
July 24.15 16.98
August 24.04 17.08
September 23.89 13.78
October 22.95 9.83
November 22.06 5.28
December 21.77 3.63
     
Annual Sum or Average 23.08 9.74
Minimum of Months 21.77 3.20
Maximum of Months 24.15 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S2 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.77 3.20
February 22.36 5.10
March 22.58 6.09
April 23.33 8.68
May 23.95 11.83
June 24.00 15.06
July 24.16 16.98
August 24.04 17.08
September 23.89 13.78
October 22.96 9.83
November 22.06 5.28
December 21.77 3.63
     
Annual Sum or Average 23.08 9.74
Minimum of Months 21.77 3.20
Maximum of Months 24.16 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 CORRIDOR

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.66 3.20
February 22.37 5.10
March 22.63 6.09
April 23.65 8.68
May 24.81 11.83
June 25.42 15.06
July 25.88 16.98
August 25.55 17.08
September 24.65 13.78
October 23.02 9.83
November 21.98 5.28
December 21.48 3.63
     
Annual Sum or Average 23.60 9.74
Minimum of Months 21.48 3.20
Maximum of Months 25.88 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SW APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 3.20
February 22.06 5.10
March 22.37 6.09
April 23.00 8.68
May 23.68 11.83
June 23.97 15.06
July 24.15 16.98
August 24.01 17.08
September 23.65 13.78
October 22.52 9.83
November 21.90 5.28
December 21.72 3.63
     
Annual Sum or Average 22.90 9.74
Minimum of Months 21.72 3.20
Maximum of Months 24.15 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NW APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.86 6.09
April 22.14 8.68
May 23.18 11.83
June 23.72 15.06
July 24.03 16.98
August 23.71 17.08
September 22.82 13.78
October 21.86 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.51 9.74
Minimum of Months 21.70 3.20
Maximum of Months 24.03 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SE APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 3.20
February 22.02 5.10
March 22.34 6.09
April 22.93 8.68
May 23.63 11.83
June 23.91 15.06
July 24.15 16.98
August 24.01 17.08
September 23.61 13.78
October 22.52 9.83
November 21.88 5.28
December 21.72 3.63
     
Annual Sum or Average 22.88 9.74
Minimum of Months 21.72 3.20
Maximum of Months 24.15 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NE APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.80 6.09
April 22.04 8.68
May 23.01 11.83
June 23.55 15.06
July 23.93 16.98
August 23.62 17.08
September 22.65 13.78
October 21.85 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.44 9.74
Minimum of Months 21.70 3.20
Maximum of Months 23.93 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N1 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.82 6.09
April 21.98 8.68
May 23.03 11.83
June 23.55 15.06
July 23.89 16.98
August 23.53 17.08
September 22.68 13.78
October 21.89 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.43 9.74
Minimum of Months 21.70 3.20
Maximum of Months 23.89 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N2 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.82 6.09
April 21.97 8.68
May 23.00 11.83
June 23.52 15.06
July 23.87 16.98
August 23.51 17.08
September 22.66 13.78
October 21.89 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.43 9.74
Minimum of Months 21.70 3.20
Maximum of Months 23.87 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S1 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.76 3.20
February 22.27 5.10
March 22.52 6.09
April 23.22 8.68
May 23.86 11.83
June 23.96 15.06
July 24.13 16.98
August 24.02 17.08
September 23.82 13.78
October 22.84 9.83
November 22.01 5.28
December 21.75 3.63
     
Annual Sum or Average 23.02 9.74
Minimum of Months 21.75 3.20
Maximum of Months 24.13 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S2 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.76 3.20
February 22.26 5.10
March 22.52 6.09
April 23.21 8.68
May 23.86 11.83
June 23.96 15.06
July 24.13 16.98
August 24.02 17.08
September 23.81 13.78
October 22.84 9.83
November 22.01 5.28
December 21.75 3.63
     
Annual Sum or Average 23.02 9.74
Minimum of Months 21.75 3.20
Maximum of Months 24.13 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 CORRIDOR

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.51 3.20
February 22.22 5.10
March 22.50 6.09
April 23.53 8.68
May 24.70 11.83
June 25.37 15.06
July 25.87 16.98
August 25.52 17.08
September 24.53 13.78
October 22.87 9.83
November 21.83 5.28
December 21.34 3.63
     
Annual Sum or Average 23.49 9.74
Minimum of Months 21.34 3.20
Maximum of Months 25.87 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.75 3.20
February 22.07 5.10
March 22.28 6.09
April 22.75 8.68
May 23.34 11.83
June 23.76 15.06
July 23.97 16.98
August 23.80 17.08
September 23.32 13.78
October 22.38 9.83
November 21.89 5.28
December 21.74 3.63
     
Annual Sum or Average 22.76 9.74
Minimum of Months 21.74 3.20
Maximum of Months 23.97 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.72 5.10
March 21.90 6.09
April 22.23 8.68
May 22.96 11.83
June 23.50 15.06
July 23.78 16.98
August 23.47 17.08
September 22.64 13.78
October 21.91 9.83
November 21.71 5.28
December 21.70 3.63
     
Annual Sum or Average 22.44 9.74
Minimum of Months 21.70 3.20
Maximum of Months 23.78 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.75 3.20
February 22.04 5.10
March 22.25 6.09
April 22.73 8.68
May 23.32 11.83
June 23.69 15.06
July 23.95 16.98
August 23.80 17.08
September 23.28 13.78
October 22.39 9.83
November 21.88 5.28
December 21.74 3.63
     
Annual Sum or Average 22.74 9.74
Minimum of Months 21.74 3.20
Maximum of Months 23.95 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.84 6.09
April 22.14 8.68
May 22.88 11.83
June 23.36 15.06
July 23.69 16.98
August 23.38 17.08
September 22.53 13.78
October 21.88 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.38 9.74
Minimum of Months 21.70 3.20
Maximum of Months 23.69 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.84 6.09
April 22.08 8.68
May 22.88 11.83
June 23.38 15.06
July 23.70 16.98
August 23.35 17.08
September 22.52 13.78
October 21.89 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.37 9.74
Minimum of Months 21.70 3.20
Maximum of Months 23.70 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 3.20
February 21.70 5.10
March 21.84 6.09
April 22.07 8.68
May 22.87 11.83
June 23.36 15.06
July 23.69 16.98
August 23.34 17.08
September 22.51 13.78
October 21.89 9.83
November 21.70 5.28
December 21.70 3.63
     
Annual Sum or Average 22.37 9.74
Minimum of Months 21.70 3.20
Maximum of Months 23.69 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.78 3.20
February 22.16 5.10
March 22.38 6.09
April 22.89 8.68
May 23.52 11.83
June 23.83 15.06
July 24.02 16.98
August 23.89 17.08
September 23.53 13.78
October 22.58 9.83
November 21.95 5.28
December 21.78 3.63
     
Annual Sum or Average 22.86 9.74
Minimum of Months 21.78 3.20
Maximum of Months 24.02 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.78 3.20
February 22.16 5.10
March 22.38 6.09
April 22.88 8.68
May 23.51 11.83
June 23.82 15.06
July 24.02 16.98
August 23.89 17.08
September 23.53 13.78
October 22.59 9.83
November 21.95 5.28
December 21.78 3.63
     
Annual Sum or Average 22.86 9.74
Minimum of Months 21.78 3.20
Maximum of Months 24.02 17.08



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2015-09-09 19:12:21

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.44 3.20
February 22.21 5.10
March 22.62 6.09
April 23.77 8.68
May 25.02 11.83
June 25.89 15.06
July 26.44 16.98
August 26.01 17.08
September 24.82 13.78
October 23.01 9.83
November 21.81 5.28
December 21.33 3.63
     
Annual Sum or Average 23.71 9.74
Minimum of Months 21.33 3.20
Maximum of Months 26.44 17.08



Table of Contents

Report: COMPONENTS OF PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2015-09-09 19:12:21

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY {AT MAX/MIN} [W] HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W]
January 0.240809E+12 138860.378 09-JAN-17:15 11327.174 57142.088 17544.917 38809.779 0.000 10364.000 1677.224 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
February 0.199188E+12 144936.822 17-FEB-17:30 11327.174 57142.088 17544.917 44886.260 0.000 10364.000 1677.224 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
March 0.220230E+12 130539.304 04-MAR-17:00 11327.174 57042.023 17544.917 30596.155 0.000 10364.000 1677.224 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
April 0.196792E+12 122611.349 29-APR-17:15 13120.457 57042.023 17544.917 0.000 30128.168 0.000 1677.224 1110.748 0.000 0.000 0.000 0.000 0.000 0.000 0.000
May 0.198655E+12 115672.123 23-MAY-19:00 14401.373 49889.926 17544.917 0.000 19382.067 10364.000 1677.224 771.312 0.000 0.000 0.000 0.000 0.000 0.000 0.000
June 0.194088E+12 136154.679 28-JUN-17:00 13120.457 57042.023 17544.917 0.000 43165.166 0.000 1677.224 1616.884 0.000 0.000 0.000 0.000 0.000 0.000 0.000
July 0.216965E+12 146997.284 11-JUL-17:15 13120.457 57042.023 17544.917 0.000 53689.936 0.000 1677.224 1934.916 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 0.210428E+12 138981.765 12-AUG-17:15 13120.457 57042.023 17544.917 0.000 45895.220 0.000 1677.224 1714.113 0.000 0.000 0.000 0.000 0.000 0.000 0.000
September 0.197914E+12 136597.400 13-SEP-16:15 11327.174 57142.088 17544.917 0.000 45130.163 0.000 1677.224 1780.637 0.000 0.000 0.000 0.000 0.000 0.000 0.000
October 0.207490E+12 111666.161 27-OCT-17:00 13120.457 57042.023 17544.917 9929.531 0.000 10364.000 1677.224 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
November 0.223282E+12 154277.434 20-NOV-17:00 11327.174 57142.088 17544.917 54226.872 0.000 10364.000 1677.224 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
December 0.249496E+12 163265.216 16-DEC-17:15 11327.174 57042.023 17544.917 63322.236 0.000 10364.000 1677.224 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
                                     
Annual Sum or Average 0.255534E+13                     0.000 0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.194088E+12 111666.161   11327.174 49889.926 17544.917 0.000 0.000 0.000 1677.224 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.249496E+12 163265.216   14401.373 57142.088 17544.917 63322.236 53689.936 10364.000 1677.224 1934.916 0.000 0.000 0.000 0.000 0.000 0.000 0.000



Table of Contents

Report: COMPONENTS OF PEAK GAS DEMAND

For: Meter

Timestamp: 2015-09-09 19:12:21

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC [Invalid/Undefined] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT {AT MAX/MIN} [W] WATERSYSTEMS:GAS {AT MAX/MIN} [W] WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] HEATING:GAS {AT MAX/MIN} [W]
January 0.283876E+12 216010.668 09-JAN-08:45 0.000 0.000 0.000 216010.668 77649.086 77649.086 138361.582
February 0.185278E+12 231766.602 17-FEB-17:30 0.000 0.000 0.000 231766.602 70811.043 70811.043 160955.558
March 0.202360E+12 198831.409 20-MAR-07:45 0.000 0.000 0.000 198831.409 78951.274 78951.274 119880.135
April 0.125058E+12 222705.551 15-APR-05:00 0.000 0.000 0.000 222705.551 77378.439 77378.439 145327.112
May 0.101825E+12 100455.044 16-MAY-07:30 0.000 0.000 0.000 100455.044 77172.186 77172.186 23282.858
June 0.936225E+11 77699.218 02-JUN-06:00 0.000 0.000 0.000 77699.218 77699.218 77699.218 0.000
July 0.942978E+11 76707.876 01-JUL-06:00 0.000 0.000 0.000 76707.876 76707.876 76707.876 0.000
August 0.934266E+11 76127.744 01-AUG-06:00 0.000 0.000 0.000 76127.744 76127.744 76127.744 0.000
September 0.959984E+11 144833.776 01-SEP-13:45 0.000 0.000 0.000 144833.776 31923.156 31923.156 112910.620
October 0.134447E+12 174392.219 28-OCT-05:15 0.000 0.000 0.000 174392.219 66267.174 66267.174 108125.046
November 0.228366E+12 243575.375 20-NOV-18:30 0.000 0.000 0.000 243575.375 73530.092 73530.092 170045.283
December 0.312958E+12 258166.951 16-DEC-18:00 0.000 0.000 0.000 258166.951 74728.682 74728.682 183438.269
                     
Annual Sum or Average 0.195151E+13     0.000 0.000 0.000        
Minimum of Months 0.934266E+11 76127.744   0.000 0.000 0.000 76127.744 31923.156 31923.156 0.000
Maximum of Months 0.312958E+12 258166.951   0.000 0.000 0.000 258166.951 78951.274 78951.274 183438.269