Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:59
Tabular Output Report in Format: HTML
Building: High-Rise Apartment
Environment: Duluth International Arpt MN USA TMY3 WMO#=727450
Simulation Timestamp: 2015-09-09 19:00:30
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 6572.78 | 838.74 | 931.00 |
Net Site Energy | 6572.78 | 838.74 | 931.00 |
Total Source Energy | 13474.99 | 1719.52 | 1908.67 |
Net Source Energy | 13474.99 | 1719.52 | 1908.67 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 7836.48 |
Net Conditioned Building Area | 7059.89 |
Unconditioned Building Area | 776.58 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 567.85 | 2181.16 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 144.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 296.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 162.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1137.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 631.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 65.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 6.37 | 0.00 | 0.00 | 0.00 | 0.00 | 452.49 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 1343.09 | 0.00 | 0.00 | 0.00 | 4778.51 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 3048.54 | 3524.24 | 0.00 | 0.00 | 0.00 | 5231.00 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Boiler | 0.00 | 2181.16 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Other | 567.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 144.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 242.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 54.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 162.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 1137.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 631.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 65.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 6.37 | 0.00 | 0.00 | 0.00 | 0.00 | 452.49 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 1343.09 | 0.00 | 0.00 | 0.00 | 0.00 |
sub cat | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4778.51 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 65.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 200.56 | 499.19 | 0.00 | 0.00 | 0.00 | 0.74 |
Other | 161.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 431.81 | 499.19 | 0.00 | 0.00 | 0.00 | 0.74 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 58.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 180.68 | 449.72 | 0.00 | 0.00 | 0.00 | 0.67 |
Other | 145.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 389.02 | 449.72 | 0.00 | 0.00 | 0.00 | 0.67 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 3048.54 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 3048.54 | 100.00 |
Total On-Site and Utility Electric Sources | 3048.54 | 100.00 |
Total Electricity End Uses | 3048.54 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 5231.00 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 5231.00 | 100.00 |
Total Water End Uses | 5231.00 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 109.00 |
Time Setpoint Not Met During Occupied Cooling | 51.75 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 4000.75 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |COMPONENTS OF PEAK ELECTRICAL DEMAND
| Meter |COMPONENTS OF PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:59 |
RunPeriod | Duluth International Arpt MN USA TMY3 WMO#=727450 |
Weather File | Duluth International Arpt MN USA TMY3 WMO#=727450 |
Latitude [deg] | 46.83 |
Longitude [deg] | -92.2 |
Elevation [m] | 433.00 |
Time Zone | -6.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 3855.02 | 1411.96 | 515.55 | 1411.96 | 515.55 |
Window Opening Area [m2] | 1150.39 | 423.59 | 152.73 | 423.59 | 150.48 |
Window-Wall Ratio [%] | 29.84 | 30.00 | 29.62 | 30.00 | 29.19 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 3752.84 | 1411.96 | 464.46 | 1411.96 | 464.46 |
Window Opening Area [m2] | 1125.85 | 423.59 | 139.34 | 423.59 | 139.34 |
Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 29.5362 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 4.47 | 6.7128 | 0.0000 | |
F2 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F3 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F4 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
M SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 13.4255 | 0.0000 | |
F6 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F7 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F8 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F9 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
T SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 264.3872 | |
Total | 7836.48 | 23884.04 | 3855.02 | 1150.39 | 4.3335 | 39.48 | 8.6291 | |||
Conditioned Total | 7059.89 | 21517.16 | 3752.84 | 1125.85 | 3.9979 | 35.57 | 6.6700 | |||
Unconditioned Total | 776.58 | 2366.87 | 102.18 | 24.54 | 7.3840 | 26.4387 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 11-JAN-11:00 | 09-JAN-07:30 | - | - | - | 25-JUN-17:30 |
Heating | 222001.39 | 329031.97 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 9104.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 36356.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 20017.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 2145.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 86889.94 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 290808.57 | 415921.91 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | Boiler | 0.00 | 329031.97 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 7140.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 1964.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 36356.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 20017.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 2145.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 86889.94 | 0.00 | 0.00 | 0.00 | 0.00 |
sub cat | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 1798.37 | 2364.37 | 0.00 | 0.00 | 0.00 |
Cooling | 457.73 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 939.20 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 514.89 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 3601.91 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 1999.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 208.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 20.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 1455.91 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 9654.71 | 3820.28 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 254.73 | 334.90 | 0.00 | 0.00 | 0.00 |
Cooling | 64.84 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 133.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 72.93 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 510.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 283.18 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 29.56 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 2.86 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 206.22 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1367.54 | 541.12 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 254.73 | 334.90 | 0.00 | 0.00 | 0.00 |
Cooling | 64.84 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 133.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 72.93 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 510.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 283.18 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 29.56 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 2.86 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 206.22 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1367.54 | 541.12 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | -28.60 | 0.00 | -28.60 | Wetbulb [C] | 4.60 | 310.00 |
DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 29.20 | 10.90 | 21.00 | Wetbulb [C] | 5.20 | 220.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 270.00 | 180.00 | |
F2 WWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
F2 SWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F2 NWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F2 WWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
F2 EWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
F2 SWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F2 NWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F2 EWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
F2 NWALL N1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F2 NWALL N2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F2 SWALL S1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F2 SWALL S2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F2 WWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 270.00 | 90.00 | W |
F2 EWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 90.00 | 90.00 | E |
F3 WWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
F3 SWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F3 NWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F3 WWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
F3 EWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
F3 SWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F3 NWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F3 EWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
F3 NWALL N1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F3 NWALL N2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F3 SWALL S1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F3 SWALL S2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F3 WWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 270.00 | 90.00 | W |
F3 EWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 90.00 | 90.00 | E |
F4 WWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
F4 SWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F4 NWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F4 WWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
F4 EWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
F4 SWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F4 NWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F4 EWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
F4 NWALL N1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F4 NWALL N2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F4 SWALL S1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F4 SWALL S2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F4 WWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 270.00 | 90.00 | W |
F4 EWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 90.00 | 90.00 | E |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
M WWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 90.00 | 90.00 | E |
F6 WWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
F6 SWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F6 NWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F6 WWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
F6 EWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
F6 SWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F6 NWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F6 EWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
F6 NWALL N1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F6 NWALL N2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F6 SWALL S1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F6 SWALL S2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F6 WWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 270.00 | 90.00 | W |
F6 EWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 90.00 | 90.00 | E |
F7 WWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
F7 SWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F7 NWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F7 WWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
F7 EWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
F7 SWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F7 NWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F7 EWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
F7 NWALL N1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F7 NWALL N2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F7 SWALL S1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F7 SWALL S2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F7 WWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 270.00 | 90.00 | W |
F7 EWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 90.00 | 90.00 | E |
F8 WWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
F8 SWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F8 NWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F8 WWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
F8 EWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
F8 SWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F8 NWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F8 EWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
F8 NWALL N1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F8 NWALL N2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F8 SWALL S1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F8 SWALL S2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F8 WWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 270.00 | 90.00 | W |
F8 EWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 90.00 | 90.00 | E |
F9 WWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
F9 SWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F9 NWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F9 WWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
F9 EWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
F9 SWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F9 NWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F9 EWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
F9 NWALL N1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F9 NWALL N2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
F9 SWALL S1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F9 SWALL S2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
F9 WWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 270.00 | 90.00 | W |
F9 EWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 90.00 | 90.00 | E |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.30 | 0.219 | 0.228 | 88.25 | 0.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.30 | 0.219 | 0.228 | 88.25 | 0.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.30 | 0.219 | 0.228 | 88.25 | 0.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.30 | 0.219 | 0.228 | 88.25 | 0.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.30 | 0.219 | 0.228 | 88.25 | 0.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.30 | 0.219 | 0.228 | 88.25 | 0.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.30 | 0.219 | 0.228 | 88.25 | 0.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.30 | 0.219 | 0.228 | 88.25 | 0.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.30 | 0.219 | 0.228 | 77.66 | 0.00 | 0.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW3 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW2 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW4 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW6 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW8 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW5 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW7 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW9 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW10 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW11 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW12 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
GWINDOW13 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | G WWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_0.42_SHGC_0.45 | 3.36 | 0.00 | 0.00 | 3.36 | 3.36 | 2.493 | 0.426 | 0.308 | No | G EWALL C | 90.00 | 90.00 | E | ||
F2WINDOW2 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F2 WWALL SWA | 270.00 | 90.00 | W | ||
F2WINDOW3 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F2 SWALL SWA | 180.00 | 90.00 | S | ||
F2WINDOW4 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F2 NWALL NWA | 0.00 | 90.00 | N | ||
F2WINDOW6 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F2 WWALL NWA | 270.00 | 90.00 | W | ||
F2WINDOW8 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F2 EWALL SEA | 90.00 | 90.00 | E | ||
F2WINDOW1 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F2 SWALL SEA | 180.00 | 90.00 | S | ||
F2WINDOW5 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F2 NWALL NEA | 0.00 | 90.00 | N | ||
F2WINDOW7 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F2 EWALL NEA | 90.00 | 90.00 | E | ||
F2WINDOW9 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F2 NWALL N1A | 0.00 | 90.00 | N | ||
F2WINDOW10 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F2 NWALL N2A | 0.00 | 90.00 | N | ||
F2WINDOW11 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F2 SWALL S1A | 180.00 | 90.00 | S | ||
F2WINDOW12 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F2 SWALL S2A | 180.00 | 90.00 | S | ||
F2WINDOW13 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F2 WWALL C | 270.00 | 90.00 | W | ||
F2WINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F2 EWALL C | 90.00 | 90.00 | E | ||
F3WINDOW2 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F3 WWALL SWA | 270.00 | 90.00 | W | ||
F3WINDOW3 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F3 SWALL SWA | 180.00 | 90.00 | S | ||
F3WINDOW4 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F3 NWALL NWA | 0.00 | 90.00 | N | ||
F3WINDOW6 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F3 WWALL NWA | 270.00 | 90.00 | W | ||
F3WINDOW8 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F3 EWALL SEA | 90.00 | 90.00 | E | ||
F3WINDOW1 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F3 SWALL SEA | 180.00 | 90.00 | S | ||
F3WINDOW5 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F3 NWALL NEA | 0.00 | 90.00 | N | ||
F3WINDOW7 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F3 EWALL NEA | 90.00 | 90.00 | E | ||
F3WINDOW9 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F3 NWALL N1A | 0.00 | 90.00 | N | ||
F3WINDOW10 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F3 NWALL N2A | 0.00 | 90.00 | N | ||
F3WINDOW11 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F3 SWALL S1A | 180.00 | 90.00 | S | ||
F3WINDOW12 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F3 SWALL S2A | 180.00 | 90.00 | S | ||
F3WINDOW13 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F3 WWALL C | 270.00 | 90.00 | W | ||
F3WINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F3 EWALL C | 90.00 | 90.00 | E | ||
F4WINDOW2 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F4 WWALL SWA | 270.00 | 90.00 | W | ||
F4WINDOW3 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F4 SWALL SWA | 180.00 | 90.00 | S | ||
F4WINDOW4 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F4 NWALL NWA | 0.00 | 90.00 | N | ||
F4WINDOW6 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F4 WWALL NWA | 270.00 | 90.00 | W | ||
F4WINDOW8 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F4 EWALL SEA | 90.00 | 90.00 | E | ||
F4WINDOW1 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F4 SWALL SEA | 180.00 | 90.00 | S | ||
F4WINDOW5 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F4 NWALL NEA | 0.00 | 90.00 | N | ||
F4WINDOW7 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F4 EWALL NEA | 90.00 | 90.00 | E | ||
F4WINDOW9 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F4 NWALL N1A | 0.00 | 90.00 | N | ||
F4WINDOW10 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F4 NWALL N2A | 0.00 | 90.00 | N | ||
F4WINDOW11 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F4 SWALL S1A | 180.00 | 90.00 | S | ||
F4WINDOW12 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F4 SWALL S2A | 180.00 | 90.00 | S | ||
F4WINDOW13 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F4 WWALL C | 270.00 | 90.00 | W | ||
F4WINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F4 EWALL C | 90.00 | 90.00 | E | ||
MWINDOW2 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW3 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW4 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW6 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW8 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW5 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW7 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW9 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW10 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW11 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW12 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW13 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | M WWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | M EWALL C | 90.00 | 90.00 | E | ||
F6WINDOW2 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F6 WWALL SWA | 270.00 | 90.00 | W | ||
F6WINDOW3 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F6 SWALL SWA | 180.00 | 90.00 | S | ||
F6WINDOW4 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F6 NWALL NWA | 0.00 | 90.00 | N | ||
F6WINDOW6 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F6 WWALL NWA | 270.00 | 90.00 | W | ||
F6WINDOW8 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F6 EWALL SEA | 90.00 | 90.00 | E | ||
F6WINDOW1 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F6 SWALL SEA | 180.00 | 90.00 | S | ||
F6WINDOW5 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F6 NWALL NEA | 0.00 | 90.00 | N | ||
F6WINDOW7 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F6 EWALL NEA | 90.00 | 90.00 | E | ||
F6WINDOW9 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F6 NWALL N1A | 0.00 | 90.00 | N | ||
F6WINDOW10 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F6 NWALL N2A | 0.00 | 90.00 | N | ||
F6WINDOW11 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F6 SWALL S1A | 180.00 | 90.00 | S | ||
F6WINDOW12 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F6 SWALL S2A | 180.00 | 90.00 | S | ||
F6WINDOW13 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F6 WWALL C | 270.00 | 90.00 | W | ||
F6WINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F6 EWALL C | 90.00 | 90.00 | E | ||
F7WINDOW2 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F7 WWALL SWA | 270.00 | 90.00 | W | ||
F7WINDOW3 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F7 SWALL SWA | 180.00 | 90.00 | S | ||
F7WINDOW4 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F7 NWALL NWA | 0.00 | 90.00 | N | ||
F7WINDOW6 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F7 WWALL NWA | 270.00 | 90.00 | W | ||
F7WINDOW8 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F7 EWALL SEA | 90.00 | 90.00 | E | ||
F7WINDOW1 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F7 SWALL SEA | 180.00 | 90.00 | S | ||
F7WINDOW5 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F7 NWALL NEA | 0.00 | 90.00 | N | ||
F7WINDOW7 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F7 EWALL NEA | 90.00 | 90.00 | E | ||
F7WINDOW9 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F7 NWALL N1A | 0.00 | 90.00 | N | ||
F7WINDOW10 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F7 NWALL N2A | 0.00 | 90.00 | N | ||
F7WINDOW11 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F7 SWALL S1A | 180.00 | 90.00 | S | ||
F7WINDOW12 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F7 SWALL S2A | 180.00 | 90.00 | S | ||
F7WINDOW13 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F7 WWALL C | 270.00 | 90.00 | W | ||
F7WINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F7 EWALL C | 90.00 | 90.00 | E | ||
F8WINDOW2 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F8 WWALL SWA | 270.00 | 90.00 | W | ||
F8WINDOW3 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F8 SWALL SWA | 180.00 | 90.00 | S | ||
F8WINDOW4 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F8 NWALL NWA | 0.00 | 90.00 | N | ||
F8WINDOW6 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F8 WWALL NWA | 270.00 | 90.00 | W | ||
F8WINDOW8 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F8 EWALL SEA | 90.00 | 90.00 | E | ||
F8WINDOW1 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F8 SWALL SEA | 180.00 | 90.00 | S | ||
F8WINDOW5 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F8 NWALL NEA | 0.00 | 90.00 | N | ||
F8WINDOW7 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F8 EWALL NEA | 90.00 | 90.00 | E | ||
F8WINDOW9 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F8 NWALL N1A | 0.00 | 90.00 | N | ||
F8WINDOW10 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F8 NWALL N2A | 0.00 | 90.00 | N | ||
F8WINDOW11 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F8 SWALL S1A | 180.00 | 90.00 | S | ||
F8WINDOW12 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F8 SWALL S2A | 180.00 | 90.00 | S | ||
F8WINDOW13 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F8 WWALL C | 270.00 | 90.00 | W | ||
F8WINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F8 EWALL C | 90.00 | 90.00 | E | ||
F9WINDOW2 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F9 WWALL SWA | 270.00 | 90.00 | W | ||
F9WINDOW3 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F9 SWALL SWA | 180.00 | 90.00 | S | ||
F9WINDOW4 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F9 NWALL NWA | 0.00 | 90.00 | N | ||
F9WINDOW6 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F9 WWALL NWA | 270.00 | 90.00 | W | ||
F9WINDOW8 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F9 EWALL SEA | 90.00 | 90.00 | E | ||
F9WINDOW1 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F9 SWALL SEA | 180.00 | 90.00 | S | ||
F9WINDOW5 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F9 NWALL NEA | 0.00 | 90.00 | N | ||
F9WINDOW7 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | F9 EWALL NEA | 90.00 | 90.00 | E | ||
F9WINDOW9 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F9 NWALL N1A | 0.00 | 90.00 | N | ||
F9WINDOW10 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F9 NWALL N2A | 0.00 | 90.00 | N | ||
F9WINDOW11 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F9 SWALL S1A | 180.00 | 90.00 | S | ||
F9WINDOW12 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | F9 SWALL S2A | 180.00 | 90.00 | S | ||
F9WINDOW13 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F9 WWALL C | 270.00 | 90.00 | W | ||
F9WINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | F9 EWALL C | 90.00 | 90.00 | E | ||
TWINDOW2 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW3 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW4 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW6 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW8 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW5 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW7 | WINDOW_U_0.42_SHGC_0.45 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.493 | 0.426 | 0.308 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW9 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW10 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW11 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW12 | WINDOW_U_0.42_SHGC_0.45 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.493 | 0.426 | 0.308 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW13 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | T WWALL C | 270.00 | 90.00 | W | ||
TWINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | T EWALL C | 90.00 | 90.00 | E | ||
Total or Average | 1150.39 | 2.493 | 0.426 | 0.308 | ||||||||||||
North Total or Average | 423.59 | 2.493 | 0.426 | 0.308 | ||||||||||||
Non-North Total or Average | 726.80 | 2.493 | 0.426 | 0.308 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
G SW APARTMENT_LIGHTS_HARDWIRED | G SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G NW APARTMENT_LIGHTS_HARDWIRED | G NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
OFFICE_LIGHTS_HARDWIRED | OFFICE | 14.7681 | 88.25 | 1303.26 | GeneralLights | LTG_OFF_SCH | 62.05 | 168.00 | 61.07 | 0.0000 | Y | 14.94 |
G NE APARTMENT_LIGHTS_HARDWIRED | G NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G N1 APARTMENT_LIGHTS_HARDWIRED | G N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G N2 APARTMENT_LIGHTS_HARDWIRED | G N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G S1 APARTMENT_LIGHTS_HARDWIRED | G S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G S2 APARTMENT_LIGHTS_HARDWIRED | G S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G CORRIDOR_LIGHTS_HARDWIRED | G CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F2 SW APARTMENT_LIGHTS_HARDWIRED | F2 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 NW APARTMENT_LIGHTS_HARDWIRED | F2 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 SE APARTMENT_LIGHTS_HARDWIRED | F2 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 NE APARTMENT_LIGHTS_HARDWIRED | F2 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 N1 APARTMENT_LIGHTS_HARDWIRED | F2 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 N2 APARTMENT_LIGHTS_HARDWIRED | F2 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 S1 APARTMENT_LIGHTS_HARDWIRED | F2 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 S2 APARTMENT_LIGHTS_HARDWIRED | F2 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 CORRIDOR_LIGHTS_HARDWIRED | F2 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F3 SW APARTMENT_LIGHTS_HARDWIRED | F3 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 NW APARTMENT_LIGHTS_HARDWIRED | F3 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 SE APARTMENT_LIGHTS_HARDWIRED | F3 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 NE APARTMENT_LIGHTS_HARDWIRED | F3 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 N1 APARTMENT_LIGHTS_HARDWIRED | F3 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 N2 APARTMENT_LIGHTS_HARDWIRED | F3 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 S1 APARTMENT_LIGHTS_HARDWIRED | F3 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 S2 APARTMENT_LIGHTS_HARDWIRED | F3 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 CORRIDOR_LIGHTS_HARDWIRED | F3 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F4 SW APARTMENT_LIGHTS_HARDWIRED | F4 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 NW APARTMENT_LIGHTS_HARDWIRED | F4 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 SE APARTMENT_LIGHTS_HARDWIRED | F4 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 NE APARTMENT_LIGHTS_HARDWIRED | F4 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 N1 APARTMENT_LIGHTS_HARDWIRED | F4 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 N2 APARTMENT_LIGHTS_HARDWIRED | F4 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 S1 APARTMENT_LIGHTS_HARDWIRED | F4 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 S2 APARTMENT_LIGHTS_HARDWIRED | F4 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 CORRIDOR_LIGHTS_HARDWIRED | F4 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
M SW APARTMENT_LIGHTS_HARDWIRED | M SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M NW APARTMENT_LIGHTS_HARDWIRED | M NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M SE APARTMENT_LIGHTS_HARDWIRED | M SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M NE APARTMENT_LIGHTS_HARDWIRED | M NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M N1 APARTMENT_LIGHTS_HARDWIRED | M N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M N2 APARTMENT_LIGHTS_HARDWIRED | M N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M S1 APARTMENT_LIGHTS_HARDWIRED | M S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M S2 APARTMENT_LIGHTS_HARDWIRED | M S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M CORRIDOR_LIGHTS_HARDWIRED | M CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F6 SW APARTMENT_LIGHTS_HARDWIRED | F6 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 NW APARTMENT_LIGHTS_HARDWIRED | F6 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 SE APARTMENT_LIGHTS_HARDWIRED | F6 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 NE APARTMENT_LIGHTS_HARDWIRED | F6 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 N1 APARTMENT_LIGHTS_HARDWIRED | F6 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 N2 APARTMENT_LIGHTS_HARDWIRED | F6 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 S1 APARTMENT_LIGHTS_HARDWIRED | F6 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 S2 APARTMENT_LIGHTS_HARDWIRED | F6 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 CORRIDOR_LIGHTS_HARDWIRED | F6 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F7 SW APARTMENT_LIGHTS_HARDWIRED | F7 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 NW APARTMENT_LIGHTS_HARDWIRED | F7 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 SE APARTMENT_LIGHTS_HARDWIRED | F7 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 NE APARTMENT_LIGHTS_HARDWIRED | F7 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 N1 APARTMENT_LIGHTS_HARDWIRED | F7 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 N2 APARTMENT_LIGHTS_HARDWIRED | F7 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 S1 APARTMENT_LIGHTS_HARDWIRED | F7 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 S2 APARTMENT_LIGHTS_HARDWIRED | F7 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 CORRIDOR_LIGHTS_HARDWIRED | F7 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F8 SW APARTMENT_LIGHTS_HARDWIRED | F8 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 NW APARTMENT_LIGHTS_HARDWIRED | F8 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 SE APARTMENT_LIGHTS_HARDWIRED | F8 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 NE APARTMENT_LIGHTS_HARDWIRED | F8 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 N1 APARTMENT_LIGHTS_HARDWIRED | F8 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 N2 APARTMENT_LIGHTS_HARDWIRED | F8 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 S1 APARTMENT_LIGHTS_HARDWIRED | F8 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 S2 APARTMENT_LIGHTS_HARDWIRED | F8 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 CORRIDOR_LIGHTS_HARDWIRED | F8 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F9 SW APARTMENT_LIGHTS_HARDWIRED | F9 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 NW APARTMENT_LIGHTS_HARDWIRED | F9 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 SE APARTMENT_LIGHTS_HARDWIRED | F9 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 NE APARTMENT_LIGHTS_HARDWIRED | F9 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 N1 APARTMENT_LIGHTS_HARDWIRED | F9 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 N2 APARTMENT_LIGHTS_HARDWIRED | F9 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 S1 APARTMENT_LIGHTS_HARDWIRED | F9 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 S2 APARTMENT_LIGHTS_HARDWIRED | F9 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 CORRIDOR_LIGHTS_HARDWIRED | F9 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
T SW APARTMENT_LIGHTS_HARDWIRED | T SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T NW APARTMENT_LIGHTS_HARDWIRED | T NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T SE APARTMENT_LIGHTS_HARDWIRED | T SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T NE APARTMENT_LIGHTS_HARDWIRED | T NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T N1 APARTMENT_LIGHTS_HARDWIRED | T N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T N2 APARTMENT_LIGHTS_HARDWIRED | T N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T S1 APARTMENT_LIGHTS_HARDWIRED | T S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T S2 APARTMENT_LIGHTS_HARDWIRED | T S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T CORRIDOR_LIGHTS_HARDWIRED | T CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
G SW APARTMENT_LIGHTS_PLUGIN | G SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G NW APARTMENT_LIGHTS_PLUGIN | G NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
OFFICE_LIGHTS_PLUGIN | OFFICE | 14.7681 | 88.25 | 1303.26 | GeneralLights-plugin | LTG_OFF_SCH | 62.05 | 168.00 | 61.07 | 0.0000 | Y | 14.94 |
G NE APARTMENT_LIGHTS_PLUGIN | G NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G N1 APARTMENT_LIGHTS_PLUGIN | G N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G N2 APARTMENT_LIGHTS_PLUGIN | G N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G S1 APARTMENT_LIGHTS_PLUGIN | G S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G S2 APARTMENT_LIGHTS_PLUGIN | G S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 SW APARTMENT_LIGHTS_PLUGIN | F2 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 NW APARTMENT_LIGHTS_PLUGIN | F2 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 SE APARTMENT_LIGHTS_PLUGIN | F2 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 NE APARTMENT_LIGHTS_PLUGIN | F2 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 N1 APARTMENT_LIGHTS_PLUGIN | F2 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 N2 APARTMENT_LIGHTS_PLUGIN | F2 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 S1 APARTMENT_LIGHTS_PLUGIN | F2 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 S2 APARTMENT_LIGHTS_PLUGIN | F2 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 SW APARTMENT_LIGHTS_PLUGIN | F3 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 NW APARTMENT_LIGHTS_PLUGIN | F3 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 SE APARTMENT_LIGHTS_PLUGIN | F3 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 NE APARTMENT_LIGHTS_PLUGIN | F3 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 N1 APARTMENT_LIGHTS_PLUGIN | F3 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 N2 APARTMENT_LIGHTS_PLUGIN | F3 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 S1 APARTMENT_LIGHTS_PLUGIN | F3 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 S2 APARTMENT_LIGHTS_PLUGIN | F3 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 SW APARTMENT_LIGHTS_PLUGIN | F4 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 NW APARTMENT_LIGHTS_PLUGIN | F4 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 SE APARTMENT_LIGHTS_PLUGIN | F4 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 NE APARTMENT_LIGHTS_PLUGIN | F4 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 N1 APARTMENT_LIGHTS_PLUGIN | F4 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 N2 APARTMENT_LIGHTS_PLUGIN | F4 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 S1 APARTMENT_LIGHTS_PLUGIN | F4 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 S2 APARTMENT_LIGHTS_PLUGIN | F4 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M SW APARTMENT_LIGHTS_PLUGIN | M SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M NW APARTMENT_LIGHTS_PLUGIN | M NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M SE APARTMENT_LIGHTS_PLUGIN | M SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M NE APARTMENT_LIGHTS_PLUGIN | M NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M N1 APARTMENT_LIGHTS_PLUGIN | M N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M N2 APARTMENT_LIGHTS_PLUGIN | M N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M S1 APARTMENT_LIGHTS_PLUGIN | M S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M S2 APARTMENT_LIGHTS_PLUGIN | M S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M CORRIDOR_LIGHTS_PLUGIN | M CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights-plugin | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F6 SW APARTMENT_LIGHTS_PLUGIN | F6 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 NW APARTMENT_LIGHTS_PLUGIN | F6 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 SE APARTMENT_LIGHTS_PLUGIN | F6 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 NE APARTMENT_LIGHTS_PLUGIN | F6 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 N1 APARTMENT_LIGHTS_PLUGIN | F6 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 N2 APARTMENT_LIGHTS_PLUGIN | F6 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 S1 APARTMENT_LIGHTS_PLUGIN | F6 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 S2 APARTMENT_LIGHTS_PLUGIN | F6 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 SW APARTMENT_LIGHTS_PLUGIN | F7 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 NW APARTMENT_LIGHTS_PLUGIN | F7 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 SE APARTMENT_LIGHTS_PLUGIN | F7 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 NE APARTMENT_LIGHTS_PLUGIN | F7 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 N1 APARTMENT_LIGHTS_PLUGIN | F7 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 N2 APARTMENT_LIGHTS_PLUGIN | F7 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 S1 APARTMENT_LIGHTS_PLUGIN | F7 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 S2 APARTMENT_LIGHTS_PLUGIN | F7 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 SW APARTMENT_LIGHTS_PLUGIN | F8 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 NW APARTMENT_LIGHTS_PLUGIN | F8 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 SE APARTMENT_LIGHTS_PLUGIN | F8 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 NE APARTMENT_LIGHTS_PLUGIN | F8 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 N1 APARTMENT_LIGHTS_PLUGIN | F8 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 N2 APARTMENT_LIGHTS_PLUGIN | F8 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 S1 APARTMENT_LIGHTS_PLUGIN | F8 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 S2 APARTMENT_LIGHTS_PLUGIN | F8 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 SW APARTMENT_LIGHTS_PLUGIN | F9 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 NW APARTMENT_LIGHTS_PLUGIN | F9 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 SE APARTMENT_LIGHTS_PLUGIN | F9 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 NE APARTMENT_LIGHTS_PLUGIN | F9 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 N1 APARTMENT_LIGHTS_PLUGIN | F9 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 N2 APARTMENT_LIGHTS_PLUGIN | F9 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 S1 APARTMENT_LIGHTS_PLUGIN | F9 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 S2 APARTMENT_LIGHTS_PLUGIN | F9 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T SW APARTMENT_LIGHTS_PLUGIN | T SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T NW APARTMENT_LIGHTS_PLUGIN | T NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T SE APARTMENT_LIGHTS_PLUGIN | T SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T NE APARTMENT_LIGHTS_PLUGIN | T NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T N1 APARTMENT_LIGHTS_PLUGIN | T N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T N2 APARTMENT_LIGHTS_PLUGIN | T N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T S1 APARTMENT_LIGHTS_PLUGIN | T S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T S2 APARTMENT_LIGHTS_PLUGIN | T S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
Interior Lighting Total | 2.2679 | 14974.03 | 33959.19 | 296.56 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 10364.00 | AstronomicalClock | - | 83.57 | 83.57 | 162.58 | |
Exterior Lighting Total | 10364.00 | 162.58 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
CENTRAL BOILER | Boiler:HotWater | 303615.53 | 0.75 | ||
CENTRAL TOWER | EvaporativeFluidCooler:SingleSpeed | 242892.43 |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
HEAT PUMP COOLING MODE AIRLOOP G SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3494.72 | 2266.68 | 1228.03 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3510.52 | 2253.89 | 1256.63 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP OFFICE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5429.48 | 3594.63 | 1834.85 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3735.54 | 2316.37 | 1419.17 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2734.62 | 1641.03 | 1093.59 | 0.60 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2748.65 | 1645.72 | 1102.92 | 0.60 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2553.60 | 1601.76 | 951.84 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2529.13 | 1595.37 | 933.75 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4535.68 | 2987.25 | 1548.43 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4106.48 | 2677.26 | 1429.22 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4544.68 | 2986.41 | 1558.27 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3520.63 | 2237.83 | 1282.80 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2311.88 | 1433.75 | 878.13 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2290.15 | 1418.48 | 871.67 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3179.81 | 2044.87 | 1134.93 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3215.43 | 2070.74 | 1144.69 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4615.28 | 3021.57 | 1593.71 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4214.15 | 2730.82 | 1483.33 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4339.47 | 2814.85 | 1524.62 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3707.02 | 2343.93 | 1363.09 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2404.18 | 1488.82 | 915.36 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2382.52 | 1473.64 | 908.88 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3273.79 | 2099.72 | 1174.07 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3290.67 | 2111.98 | 1178.69 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4662.50 | 3038.66 | 1623.84 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4264.62 | 2751.14 | 1513.48 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4364.16 | 2816.41 | 1547.75 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3937.18 | 2477.15 | 1460.03 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2441.97 | 1508.07 | 933.90 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2420.29 | 1492.93 | 927.36 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3313.17 | 2118.44 | 1194.73 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3327.37 | 2128.73 | 1198.64 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4727.00 | 3071.57 | 1655.43 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4331.99 | 2786.74 | 1545.25 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4431.34 | 2851.77 | 1579.56 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4113.64 | 2580.76 | 1532.89 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2497.40 | 1541.08 | 956.32 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2477.54 | 1527.09 | 950.45 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3369.75 | 2151.38 | 1218.37 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3383.58 | 2161.40 | 1222.18 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4724.80 | 3056.08 | 1668.72 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4310.11 | 2760.44 | 1549.66 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4414.82 | 2829.13 | 1585.70 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4357.64 | 2719.10 | 1638.54 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2628.86 | 1614.47 | 1014.39 | 0.61 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2634.80 | 1616.26 | 1018.54 | 0.61 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3342.16 | 2125.01 | 1217.14 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3355.99 | 2135.01 | 1220.98 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4731.90 | 3051.39 | 1680.51 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4338.99 | 2770.20 | 1568.79 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4424.29 | 2826.63 | 1597.67 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4542.98 | 2824.74 | 1718.24 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2746.72 | 1682.11 | 1064.62 | 0.61 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2752.95 | 1684.00 | 1068.95 | 0.61 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3341.47 | 2118.90 | 1222.58 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3355.33 | 2128.89 | 1226.44 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4752.25 | 3057.35 | 1694.91 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4502.70 | 2867.92 | 1634.78 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4498.51 | 2867.45 | 1631.06 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4717.07 | 2925.45 | 1791.62 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2859.93 | 1748.56 | 1111.37 | 0.61 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2866.33 | 1750.50 | 1115.83 | 0.61 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3354.68 | 2123.37 | 1231.30 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3368.59 | 2133.39 | 1235.20 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4854.53 | 3125.15 | 1729.38 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4762.06 | 3034.87 | 1727.18 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4768.51 | 3039.08 | 1729.43 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5004.16 | 3100.42 | 1903.74 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3067.86 | 1881.47 | 1186.39 | 0.61 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3074.38 | 1883.43 | 1190.95 | 0.61 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3428.79 | 2171.46 | 1257.33 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3441.45 | 2180.80 | 1260.65 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5702.34 | 3721.46 | 1980.87 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5362.38 | 3461.01 | 1901.37 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5332.29 | 3448.08 | 1884.21 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5603.29 | 3524.05 | 2079.23 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3839.49 | 2388.13 | 1451.37 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3845.33 | 2390.75 | 1454.58 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4277.30 | 2777.85 | 1499.45 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4290.87 | 2787.76 | 1503.11 | 0.65 | 0.00 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
None |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
HEAT PUMP HEATING MODE AIRLOOP G SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 3494.72 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 3510.52 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP OFFICE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5429.48 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3735.54 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2734.62 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2748.65 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2553.60 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2529.13 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4535.68 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4106.48 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4544.68 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3520.63 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2311.88 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2290.15 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3179.81 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3215.43 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4615.28 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4214.15 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4339.47 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3707.02 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2404.18 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2382.52 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3273.79 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3290.67 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4662.50 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4264.62 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4364.16 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3937.18 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2441.97 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2420.29 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3313.17 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3327.37 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4727.00 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4331.99 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4431.34 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4113.64 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2497.40 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2477.54 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3369.75 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3383.58 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4724.80 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4310.11 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4414.82 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4357.64 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2628.86 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2634.80 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3342.16 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3355.99 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4731.90 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4338.99 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4424.29 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4542.98 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2746.72 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2752.95 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3341.47 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3355.33 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4752.25 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4502.70 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4498.51 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4717.07 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2859.93 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2866.33 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3354.68 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3368.59 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4854.53 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4762.06 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4768.51 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5004.16 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3067.86 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3074.38 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3428.79 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3441.45 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5702.34 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5362.38 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5332.29 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5603.29 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3839.49 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3845.33 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4277.30 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4290.87 | 0.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW | Coil:Heating:Electric | 5790.18 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW | Coil:Heating:Electric | 5797.70 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE | Coil:Heating:Electric | 6934.29 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE | Coil:Heating:Electric | 5800.02 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 | Coil:Heating:Electric | 4447.31 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 | Coil:Heating:Electric | 4447.35 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 | Coil:Heating:Electric | 4437.51 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 | Coil:Heating:Electric | 4443.83 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW | Coil:Heating:Electric | 5756.77 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW | Coil:Heating:Electric | 5760.11 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE | Coil:Heating:Electric | 5771.78 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE | Coil:Heating:Electric | 5757.17 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 | Coil:Heating:Electric | 4049.99 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 | Coil:Heating:Electric | 4049.93 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 | Coil:Heating:Electric | 4049.80 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 | Coil:Heating:Electric | 4050.82 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW | Coil:Heating:Electric | 5934.99 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW | Coil:Heating:Electric | 5946.68 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE | Coil:Heating:Electric | 5930.08 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE | Coil:Heating:Electric | 5939.98 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 | Coil:Heating:Electric | 4101.16 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 | Coil:Heating:Electric | 4101.01 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 | Coil:Heating:Electric | 4090.68 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 | Coil:Heating:Electric | 4090.69 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW | Coil:Heating:Electric | 6165.08 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW | Coil:Heating:Electric | 6181.89 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE | Coil:Heating:Electric | 6155.84 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE | Coil:Heating:Electric | 6172.48 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 | Coil:Heating:Electric | 4230.13 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 | Coil:Heating:Electric | 4229.93 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 | Coil:Heating:Electric | 4214.22 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 | Coil:Heating:Electric | 4214.03 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW | Coil:Heating:Electric | 6348.25 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW | Coil:Heating:Electric | 6367.52 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE | Coil:Heating:Electric | 6336.76 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE | Coil:Heating:Electric | 6356.00 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 | Coil:Heating:Electric | 4330.10 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 | Coil:Heating:Electric | 4329.84 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 | Coil:Heating:Electric | 4311.63 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 | Coil:Heating:Electric | 4311.38 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW | Coil:Heating:Electric | 6570.94 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW | Coil:Heating:Electric | 6593.79 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE | Coil:Heating:Electric | 6557.70 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE | Coil:Heating:Electric | 6580.55 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 | Coil:Heating:Electric | 4480.77 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 | Coil:Heating:Electric | 4480.48 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 | Coil:Heating:Electric | 4458.67 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 | Coil:Heating:Electric | 4458.38 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW | Coil:Heating:Electric | 6750.30 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW | Coil:Heating:Electric | 6775.17 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE | Coil:Heating:Electric | 6735.63 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE | Coil:Heating:Electric | 6760.49 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 | Coil:Heating:Electric | 4596.67 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 | Coil:Heating:Electric | 4596.35 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 | Coil:Heating:Electric | 4572.53 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 | Coil:Heating:Electric | 4572.21 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW | Coil:Heating:Electric | 6924.59 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW | Coil:Heating:Electric | 6950.81 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE | Coil:Heating:Electric | 6908.67 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE | Coil:Heating:Electric | 6934.89 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 | Coil:Heating:Electric | 4713.56 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 | Coil:Heating:Electric | 4713.21 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 | Coil:Heating:Electric | 4688.06 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 | Coil:Heating:Electric | 4687.71 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW | Coil:Heating:Electric | 7248.20 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW | Coil:Heating:Electric | 7272.28 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE | Coil:Heating:Electric | 7231.03 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE | Coil:Heating:Electric | 7255.12 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 | Coil:Heating:Electric | 4969.48 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 | Coil:Heating:Electric | 4969.10 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 | Coil:Heating:Electric | 4945.66 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 | Coil:Heating:Electric | 4945.28 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW | Coil:Heating:Electric | 8113.34 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW | Coil:Heating:Electric | 8145.63 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE | Coil:Heating:Electric | 8096.51 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE | Coil:Heating:Electric | 8128.80 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 | Coil:Heating:Electric | 5870.68 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 | Coil:Heating:Electric | 5870.29 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 | Coil:Heating:Electric | 5835.47 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 | Coil:Heating:Electric | 5835.08 | 1.00 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
AIRLOOP G SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 238.81 | 1160.84 | 1.00 | General |
AIRLOOP G NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.20 | 237.16 | 1160.84 | 1.00 | General |
AIRLOOP OFFICE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 383.96 | 1160.84 | 1.00 | General |
AIRLOOP G NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.20 | 237.29 | 1160.84 | 1.00 | General |
AIRLOOP G N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.14 | 162.64 | 1160.84 | 1.00 | General |
AIRLOOP G N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.14 | 162.65 | 1160.84 | 1.00 | General |
AIRLOOP G S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.14 | 162.10 | 1160.84 | 1.00 | General |
AIRLOOP G S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.14 | 162.45 | 1160.84 | 1.00 | General |
AIRLOOP F2 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 320.93 | 1160.84 | 1.00 | General |
AIRLOOP F2 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 286.26 | 1160.84 | 1.00 | General |
AIRLOOP F2 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 318.37 | 1160.84 | 1.00 | General |
AIRLOOP F2 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.20 | 234.90 | 1160.84 | 1.00 | General |
AIRLOOP F2 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.13 | 147.44 | 1160.84 | 1.00 | General |
AIRLOOP F2 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.13 | 145.69 | 1160.84 | 1.00 | General |
AIRLOOP F2 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 212.88 | 1160.84 | 1.00 | General |
AIRLOOP F2 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 215.87 | 1160.84 | 1.00 | General |
AIRLOOP F3 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 323.26 | 1160.84 | 1.00 | General |
AIRLOOP F3 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 290.25 | 1160.84 | 1.00 | General |
AIRLOOP F3 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.26 | 296.96 | 1160.84 | 1.00 | General |
AIRLOOP F3 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 244.97 | 1160.84 | 1.00 | General |
AIRLOOP F3 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.13 | 152.91 | 1160.84 | 1.00 | General |
AIRLOOP F3 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.13 | 151.17 | 1160.84 | 1.00 | General |
AIRLOOP F3 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 218.25 | 1160.84 | 1.00 | General |
AIRLOOP F3 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 219.67 | 1160.84 | 1.00 | General |
AIRLOOP F4 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 324.03 | 1160.84 | 1.00 | General |
AIRLOOP F4 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 291.42 | 1160.84 | 1.00 | General |
AIRLOOP F4 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 295.96 | 1160.84 | 1.00 | General |
AIRLOOP F4 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 257.80 | 1160.84 | 1.00 | General |
AIRLOOP F4 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.13 | 154.48 | 1160.84 | 1.00 | General |
AIRLOOP F4 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.13 | 152.75 | 1160.84 | 1.00 | General |
AIRLOOP F4 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 219.69 | 1160.84 | 1.00 | General |
AIRLOOP F4 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 220.89 | 1160.84 | 1.00 | General |
AIRLOOP M SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 326.85 | 1160.84 | 1.00 | General |
AIRLOOP M NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 294.58 | 1160.84 | 1.00 | General |
AIRLOOP M SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.26 | 299.08 | 1160.84 | 1.00 | General |
AIRLOOP M NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 267.92 | 1160.84 | 1.00 | General |
AIRLOOP M N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.14 | 157.76 | 1160.84 | 1.00 | General |
AIRLOOP M N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.13 | 156.14 | 1160.84 | 1.00 | General |
AIRLOOP M S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 222.91 | 1160.84 | 1.00 | General |
AIRLOOP M S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 224.07 | 1160.84 | 1.00 | General |
AIRLOOP F6 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 322.99 | 1160.84 | 1.00 | General |
AIRLOOP F6 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 290.75 | 1160.84 | 1.00 | General |
AIRLOOP F6 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 295.67 | 1160.84 | 1.00 | General |
AIRLOOP F6 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 280.30 | 1160.84 | 1.00 | General |
AIRLOOP F6 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.14 | 164.47 | 1160.84 | 1.00 | General |
AIRLOOP F6 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.14 | 164.45 | 1160.84 | 1.00 | General |
AIRLOOP F6 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 219.38 | 1160.84 | 1.00 | General |
AIRLOOP F6 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 220.53 | 1160.84 | 1.00 | General |
AIRLOOP F7 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 321.73 | 1160.84 | 1.00 | General |
AIRLOOP F7 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 291.03 | 1160.84 | 1.00 | General |
AIRLOOP F7 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 294.69 | 1160.84 | 1.00 | General |
AIRLOOP F7 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 290.22 | 1160.84 | 1.00 | General |
AIRLOOP F7 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 170.86 | 1160.84 | 1.00 | General |
AIRLOOP F7 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 170.84 | 1160.84 | 1.00 | General |
AIRLOOP F7 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 218.24 | 1160.84 | 1.00 | General |
AIRLOOP F7 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 219.40 | 1160.84 | 1.00 | General |
AIRLOOP F8 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 321.78 | 1160.84 | 1.00 | General |
AIRLOOP F8 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.26 | 300.72 | 1160.84 | 1.00 | General |
AIRLOOP F8 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.26 | 298.39 | 1160.84 | 1.00 | General |
AIRLOOP F8 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.26 | 299.84 | 1160.84 | 1.00 | General |
AIRLOOP F8 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 177.31 | 1160.84 | 1.00 | General |
AIRLOOP F8 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 177.29 | 1160.84 | 1.00 | General |
AIRLOOP F8 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 218.37 | 1160.84 | 1.00 | General |
AIRLOOP F8 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 219.53 | 1160.84 | 1.00 | General |
AIRLOOP F9 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 330.23 | 1160.84 | 1.00 | General |
AIRLOOP F9 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 318.45 | 1160.84 | 1.00 | General |
AIRLOOP F9 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 316.17 | 1160.84 | 1.00 | General |
AIRLOOP F9 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 317.50 | 1160.84 | 1.00 | General |
AIRLOOP F9 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 191.43 | 1160.84 | 1.00 | General |
AIRLOOP F9 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 191.41 | 1160.84 | 1.00 | General |
AIRLOOP F9 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 223.39 | 1160.84 | 1.00 | General |
AIRLOOP F9 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 224.62 | 1160.84 | 1.00 | General |
AIRLOOP T SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.34 | 396.02 | 1160.84 | 1.00 | General |
AIRLOOP T NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 366.62 | 1160.84 | 1.00 | General |
AIRLOOP T SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 363.91 | 1160.84 | 1.00 | General |
AIRLOOP T NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 365.69 | 1160.84 | 1.00 | General |
AIRLOOP T N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 241.15 | 1160.84 | 1.00 | General |
AIRLOOP T N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 241.13 | 1160.84 | 1.00 | General |
AIRLOOP T S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 293.11 | 1160.84 | 1.00 | General |
AIRLOOP T S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 294.26 | 1160.84 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
SHWSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.0003 | 36.93 | 127739.32 | 0.30 |
PLANT CIRC PUMP | Pump:ConstantSpeed | Intermittent | 224180.02 | 0.0066 | 2108.92 | 319344.75 | 0.90 |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SHWSYS1 WATER HEATER | WaterHeater:Mixed | 2.27 | 175842.64 | 0.80 | 0.00 | 0.00 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 2079.14 | 2494.97 | 0.171 | 0.206 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 16:15:00 | 28.33 | 0.01308 |
G NW APARTMENT | 1863.01 | 2235.61 | 0.154 | 0.184 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 26.58 | 0.01308 |
OFFICE | 3342.87 | 4011.44 | 0.276 | 0.331 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 28.93 | 0.01308 |
G NE APARTMENT | 1295.48 | 1554.57 | 0.107 | 0.128 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 25.47 | 0.01308 |
G N1 APARTMENT | 874.16 | 1048.99 | 0.072 | 0.086 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
G N2 APARTMENT | 856.07 | 1027.29 | 0.071 | 0.085 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
G S1 APARTMENT | 1341.65 | 1609.98 | 0.111 | 0.133 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
G S2 APARTMENT | 1409.47 | 1691.36 | 0.116 | 0.139 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
F2 SW APARTMENT | 2793.98 | 3352.78 | 0.230 | 0.276 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 27.13 | 0.01308 |
F2 NW APARTMENT | 2492.18 | 2990.62 | 0.205 | 0.247 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 26.18 | 0.01308 |
F2 SE APARTMENT | 2771.71 | 3326.05 | 0.229 | 0.274 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 28.93 | 0.01308 |
F2 NE APARTMENT | 1853.14 | 2223.77 | 0.153 | 0.183 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 25.47 | 0.01308 |
F2 N1 APARTMENT | 1283.65 | 1540.38 | 0.106 | 0.127 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
F2 N2 APARTMENT | 1268.39 | 1522.07 | 0.105 | 0.126 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
F2 S1 APARTMENT | 1853.41 | 2224.09 | 0.153 | 0.183 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
F2 S2 APARTMENT | 1879.49 | 2255.38 | 0.155 | 0.186 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
F3 SW APARTMENT | 2814.26 | 3377.12 | 0.232 | 0.278 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 27.13 | 0.01308 |
F3 NW APARTMENT | 2526.85 | 3032.22 | 0.208 | 0.250 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 26.58 | 0.01308 |
F3 SE APARTMENT | 2585.24 | 3102.29 | 0.213 | 0.256 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 28.93 | 0.01308 |
F3 NE APARTMENT | 1893.18 | 2271.81 | 0.156 | 0.187 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 25.47 | 0.01308 |
F3 N1 APARTMENT | 1331.28 | 1597.53 | 0.110 | 0.132 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
F3 N2 APARTMENT | 1316.12 | 1579.34 | 0.109 | 0.130 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
F3 S1 APARTMENT | 1900.18 | 2280.21 | 0.157 | 0.188 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
F3 S2 APARTMENT | 1912.54 | 2295.04 | 0.158 | 0.189 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
F4 SW APARTMENT | 2820.89 | 3385.07 | 0.233 | 0.279 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 27.13 | 0.01308 |
F4 NW APARTMENT | 2537.00 | 3044.40 | 0.209 | 0.251 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 26.58 | 0.01308 |
F4 SE APARTMENT | 2576.51 | 3091.82 | 0.212 | 0.255 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 28.93 | 0.01308 |
F4 NE APARTMENT | 1899.01 | 2278.81 | 0.157 | 0.188 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 25.47 | 0.01308 |
F4 N1 APARTMENT | 1344.94 | 1613.93 | 0.111 | 0.133 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
F4 N2 APARTMENT | 1329.85 | 1595.82 | 0.110 | 0.132 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
F4 S1 APARTMENT | 1912.70 | 2295.24 | 0.158 | 0.189 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
F4 S2 APARTMENT | 1923.09 | 2307.70 | 0.159 | 0.190 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
M SW APARTMENT | 2845.39 | 3414.47 | 0.235 | 0.282 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 27.13 | 0.01308 |
M NW APARTMENT | 2564.42 | 3077.31 | 0.211 | 0.254 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 26.58 | 0.01308 |
M SE APARTMENT | 2603.66 | 3124.39 | 0.215 | 0.258 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 28.93 | 0.01308 |
M NE APARTMENT | 1922.23 | 2306.68 | 0.159 | 0.190 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 25.47 | 0.01308 |
M N1 APARTMENT | 1373.41 | 1648.10 | 0.113 | 0.136 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
M N2 APARTMENT | 1358.38 | 1630.05 | 0.112 | 0.134 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
M S1 APARTMENT | 1940.69 | 2328.82 | 0.160 | 0.192 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
M S2 APARTMENT | 1950.78 | 2340.94 | 0.161 | 0.193 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
F6 SW APARTMENT | 2811.76 | 3374.12 | 0.232 | 0.278 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 28.11 | 0.01308 |
F6 NW APARTMENT | 2531.08 | 3037.30 | 0.209 | 0.250 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 26.58 | 0.01308 |
F6 SE APARTMENT | 2573.94 | 3088.73 | 0.212 | 0.255 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 28.93 | 0.01308 |
F6 NE APARTMENT | 1887.02 | 2264.43 | 0.156 | 0.187 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 25.88 | 0.01308 |
F6 N1 APARTMENT | 1343.92 | 1612.70 | 0.111 | 0.133 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
F6 N2 APARTMENT | 1329.01 | 1594.81 | 0.110 | 0.132 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
F6 S1 APARTMENT | 1909.89 | 2291.87 | 0.157 | 0.189 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
F6 S2 APARTMENT | 1919.96 | 2303.95 | 0.158 | 0.190 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
F7 SW APARTMENT | 2800.79 | 3360.94 | 0.231 | 0.277 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 28.11 | 0.01308 |
F7 NW APARTMENT | 2519.94 | 3023.92 | 0.208 | 0.249 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 26.58 | 0.01308 |
F7 SE APARTMENT | 2565.32 | 3078.39 | 0.212 | 0.254 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 28.93 | 0.01308 |
F7 NE APARTMENT | 1874.42 | 2249.30 | 0.155 | 0.185 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 25.88 | 0.01308 |
F7 N1 APARTMENT | 1335.03 | 1602.04 | 0.110 | 0.132 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
F7 N2 APARTMENT | 1320.22 | 1584.27 | 0.109 | 0.131 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
F7 S1 APARTMENT | 1899.99 | 2279.98 | 0.157 | 0.188 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
F7 S2 APARTMENT | 1910.05 | 2292.06 | 0.157 | 0.189 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
F8 SW APARTMENT | 2801.16 | 3361.39 | 0.231 | 0.277 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 28.11 | 0.01308 |
F8 NW APARTMENT | 2520.62 | 3024.75 | 0.208 | 0.249 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 26.58 | 0.01308 |
F8 SE APARTMENT | 2567.43 | 3080.92 | 0.212 | 0.254 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 28.93 | 0.01308 |
F8 NE APARTMENT | 1872.89 | 2247.47 | 0.154 | 0.185 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 25.88 | 0.01308 |
F8 N1 APARTMENT | 1337.75 | 1605.30 | 0.110 | 0.132 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
F8 N2 APARTMENT | 1323.05 | 1587.66 | 0.109 | 0.131 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
F8 S1 APARTMENT | 1901.11 | 2281.33 | 0.157 | 0.188 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
F8 S2 APARTMENT | 1911.19 | 2293.43 | 0.158 | 0.189 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
F9 SW APARTMENT | 2874.73 | 3449.68 | 0.237 | 0.284 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 27.13 | 0.01308 |
F9 NW APARTMENT | 2593.67 | 3112.40 | 0.214 | 0.257 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 26.58 | 0.01308 |
F9 SE APARTMENT | 2623.49 | 3148.19 | 0.216 | 0.260 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
F9 NE APARTMENT | 1896.91 | 2276.30 | 0.156 | 0.188 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 25.88 | 0.01308 |
F9 N1 APARTMENT | 1400.58 | 1680.70 | 0.115 | 0.139 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
F9 N2 APARTMENT | 1385.69 | 1662.83 | 0.114 | 0.137 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
F9 S1 APARTMENT | 1944.79 | 2333.75 | 0.160 | 0.192 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 29.20 | 0.01308 |
F9 S2 APARTMENT | 1955.52 | 2346.62 | 0.161 | 0.193 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
T SW APARTMENT | 3447.32 | 4136.79 | 0.284 | 0.341 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 | 28.87 | 0.01308 |
T NW APARTMENT | 3018.86 | 3622.64 | 0.249 | 0.299 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 27.13 | 0.01308 |
T SE APARTMENT | 3117.63 | 3741.15 | 0.257 | 0.309 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 28.93 | 0.01308 |
T NE APARTMENT | 2260.06 | 2712.08 | 0.186 | 0.224 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 26.28 | 0.01308 |
T N1 APARTMENT | 1649.03 | 1978.83 | 0.136 | 0.163 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:15:00 | 29.04 | 0.01308 |
T N2 APARTMENT | 1648.76 | 1978.51 | 0.136 | 0.163 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 29.20 | 0.01308 |
T S1 APARTMENT | 2551.76 | 3062.12 | 0.210 | 0.253 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
T S2 APARTMENT | 2561.77 | 3074.13 | 0.211 | 0.253 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 3627.77 | 4353.33 | 0.170 | 0.204 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -28.60 | 0.00028 |
G NW APARTMENT | 3634.13 | 4360.95 | 0.170 | 0.204 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -28.60 | 0.00028 |
OFFICE | 4001.29 | 4801.55 | 0.187 | 0.225 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 18:45:00 | -28.60 | 0.00028 |
G NE APARTMENT | 3636.09 | 4363.31 | 0.170 | 0.204 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -28.60 | 0.00028 |
G N1 APARTMENT | 2492.15 | 2990.58 | 0.117 | 0.140 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -28.60 | 0.00028 |
G N2 APARTMENT | 2492.19 | 2990.62 | 0.117 | 0.140 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -28.60 | 0.00028 |
G S1 APARTMENT | 2483.87 | 2980.64 | 0.116 | 0.140 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -28.60 | 0.00028 |
G S2 APARTMENT | 2489.21 | 2987.05 | 0.117 | 0.140 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -28.60 | 0.00028 |
F2 SW APARTMENT | 3599.59 | 4319.51 | 0.169 | 0.202 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F2 NW APARTMENT | 3602.42 | 4322.90 | 0.169 | 0.202 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F2 SE APARTMENT | 3612.28 | 4334.73 | 0.169 | 0.203 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F2 NE APARTMENT | 3599.92 | 4319.91 | 0.169 | 0.202 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F2 N1 APARTMENT | 2156.20 | 2587.45 | 0.101 | 0.121 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F2 N2 APARTMENT | 2156.15 | 2587.38 | 0.101 | 0.121 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F2 S1 APARTMENT | 2156.05 | 2587.26 | 0.101 | 0.121 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F2 S2 APARTMENT | 2156.91 | 2588.29 | 0.101 | 0.121 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F3 SW APARTMENT | 3750.32 | 4500.38 | 0.176 | 0.211 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F3 NW APARTMENT | 3760.21 | 4512.25 | 0.176 | 0.211 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F3 SE APARTMENT | 3746.17 | 4495.40 | 0.175 | 0.211 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F3 NE APARTMENT | 3754.54 | 4505.45 | 0.176 | 0.211 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F3 N1 APARTMENT | 2199.49 | 2639.39 | 0.103 | 0.124 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F3 N2 APARTMENT | 2199.37 | 2639.24 | 0.103 | 0.124 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F3 S1 APARTMENT | 2190.63 | 2628.75 | 0.103 | 0.123 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F3 S2 APARTMENT | 2190.63 | 2628.76 | 0.103 | 0.123 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F4 SW APARTMENT | 3944.91 | 4733.89 | 0.185 | 0.222 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F4 NW APARTMENT | 3959.13 | 4750.95 | 0.185 | 0.223 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F4 SE APARTMENT | 3937.10 | 4724.52 | 0.184 | 0.221 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F4 NE APARTMENT | 3951.17 | 4741.40 | 0.185 | 0.222 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F4 N1 APARTMENT | 2308.57 | 2770.28 | 0.108 | 0.130 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F4 N2 APARTMENT | 2308.39 | 2770.07 | 0.108 | 0.130 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F4 S1 APARTMENT | 2295.11 | 2754.13 | 0.108 | 0.129 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F4 S2 APARTMENT | 2294.95 | 2753.94 | 0.108 | 0.129 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
M SW APARTMENT | 4099.82 | 4919.79 | 0.192 | 0.230 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
M NW APARTMENT | 4116.11 | 4939.33 | 0.193 | 0.231 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
M SE APARTMENT | 4090.10 | 4908.12 | 0.192 | 0.230 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
M NE APARTMENT | 4106.38 | 4927.65 | 0.192 | 0.231 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
M N1 APARTMENT | 2393.11 | 2871.73 | 0.112 | 0.135 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
M N2 APARTMENT | 2392.89 | 2871.47 | 0.112 | 0.135 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
M S1 APARTMENT | 2377.49 | 2852.99 | 0.111 | 0.134 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
M S2 APARTMENT | 2377.28 | 2852.73 | 0.111 | 0.134 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F6 SW APARTMENT | 4288.14 | 5145.77 | 0.201 | 0.241 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F6 NW APARTMENT | 4307.47 | 5168.96 | 0.202 | 0.242 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F6 SE APARTMENT | 4276.95 | 5132.34 | 0.200 | 0.240 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F6 NE APARTMENT | 4296.28 | 5155.53 | 0.201 | 0.241 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F6 N1 APARTMENT | 2520.53 | 3024.64 | 0.118 | 0.142 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F6 N2 APARTMENT | 2520.29 | 3024.34 | 0.118 | 0.142 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F6 S1 APARTMENT | 2501.84 | 3002.21 | 0.117 | 0.141 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F6 S2 APARTMENT | 2501.60 | 3001.92 | 0.117 | 0.141 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F7 SW APARTMENT | 4439.84 | 5327.80 | 0.208 | 0.250 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F7 NW APARTMENT | 4460.86 | 5353.03 | 0.209 | 0.251 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F7 SE APARTMENT | 4427.42 | 5312.91 | 0.207 | 0.249 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F7 NE APARTMENT | 4448.45 | 5338.14 | 0.208 | 0.250 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F7 N1 APARTMENT | 2618.55 | 3142.26 | 0.123 | 0.147 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F7 N2 APARTMENT | 2618.28 | 3141.93 | 0.123 | 0.147 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F7 S1 APARTMENT | 2598.14 | 3117.76 | 0.122 | 0.146 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F7 S2 APARTMENT | 2597.86 | 3117.43 | 0.122 | 0.146 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F8 SW APARTMENT | 4587.23 | 5504.68 | 0.215 | 0.258 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F8 NW APARTMENT | 4609.40 | 5531.28 | 0.216 | 0.259 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F8 SE APARTMENT | 4573.77 | 5488.52 | 0.214 | 0.257 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F8 NE APARTMENT | 4595.94 | 5515.13 | 0.215 | 0.258 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F8 N1 APARTMENT | 2717.40 | 3260.88 | 0.127 | 0.153 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F8 N2 APARTMENT | 2717.11 | 3260.53 | 0.127 | 0.153 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F8 S1 APARTMENT | 2695.83 | 3235.00 | 0.126 | 0.152 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F8 S2 APARTMENT | 2695.54 | 3234.65 | 0.126 | 0.152 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F9 SW APARTMENT | 4860.89 | 5833.07 | 0.228 | 0.273 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F9 NW APARTMENT | 4881.26 | 5857.51 | 0.229 | 0.274 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F9 SE APARTMENT | 4846.38 | 5815.65 | 0.227 | 0.272 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F9 NE APARTMENT | 4866.74 | 5840.09 | 0.228 | 0.274 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F9 N1 APARTMENT | 2933.82 | 3520.59 | 0.137 | 0.165 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F9 N2 APARTMENT | 2933.50 | 3520.20 | 0.137 | 0.165 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F9 S1 APARTMENT | 2913.68 | 3496.42 | 0.136 | 0.164 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
F9 S2 APARTMENT | 2913.36 | 3496.04 | 0.136 | 0.164 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
T SW APARTMENT | 5592.53 | 6711.03 | 0.262 | 0.314 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
T NW APARTMENT | 5619.83 | 6743.79 | 0.263 | 0.316 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
T SE APARTMENT | 5578.29 | 6693.95 | 0.261 | 0.313 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
T NE APARTMENT | 5605.60 | 6726.71 | 0.263 | 0.315 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
T N1 APARTMENT | 3695.94 | 4435.13 | 0.173 | 0.208 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
T N2 APARTMENT | 3695.60 | 4434.72 | 0.173 | 0.208 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
T S1 APARTMENT | 3666.16 | 4399.40 | 0.172 | 0.206 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
T S2 APARTMENT | 3665.83 | 4398.99 | 0.172 | 0.206 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -28.60 | 0.00028 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
AIRLOOP G SW | 0.21 | 0.21 | 0.20 | 0.20 |
AIRLOOP G NW | 0.18 | 0.18 | 0.20 | 0.20 |
AIRLOOP OFFICE | 0.33 | 0.33 | 0.22 | 0.22 |
AIRLOOP G NE | 0.13 | 0.13 | 0.20 | 0.20 |
AIRLOOP G N1 | 0.09 | 0.09 | 0.14 | 0.14 |
AIRLOOP G N2 | 0.08 | 0.08 | 0.14 | 0.14 |
AIRLOOP G S1 | 0.13 | 0.13 | 0.14 | 0.14 |
AIRLOOP G S2 | 0.14 | 0.14 | 0.14 | 0.14 |
AIRLOOP F2 SW | 0.28 | 0.28 | 0.20 | 0.20 |
AIRLOOP F2 NW | 0.25 | 0.25 | 0.20 | 0.20 |
AIRLOOP F2 SE | 0.27 | 0.27 | 0.20 | 0.20 |
AIRLOOP F2 NE | 0.18 | 0.18 | 0.20 | 0.20 |
AIRLOOP F2 N1 | 0.13 | 0.13 | 0.12 | 0.12 |
AIRLOOP F2 N2 | 0.13 | 0.13 | 0.12 | 0.12 |
AIRLOOP F2 S1 | 0.18 | 0.18 | 0.12 | 0.12 |
AIRLOOP F2 S2 | 0.19 | 0.19 | 0.12 | 0.12 |
AIRLOOP F3 SW | 0.28 | 0.28 | 0.21 | 0.21 |
AIRLOOP F3 NW | 0.25 | 0.25 | 0.21 | 0.21 |
AIRLOOP F3 SE | 0.26 | 0.26 | 0.21 | 0.21 |
AIRLOOP F3 NE | 0.19 | 0.19 | 0.21 | 0.21 |
AIRLOOP F3 N1 | 0.13 | 0.13 | 0.12 | 0.12 |
AIRLOOP F3 N2 | 0.13 | 0.13 | 0.12 | 0.12 |
AIRLOOP F3 S1 | 0.19 | 0.19 | 0.12 | 0.12 |
AIRLOOP F3 S2 | 0.19 | 0.19 | 0.12 | 0.12 |
AIRLOOP F4 SW | 0.28 | 0.28 | 0.22 | 0.22 |
AIRLOOP F4 NW | 0.25 | 0.25 | 0.22 | 0.22 |
AIRLOOP F4 SE | 0.25 | 0.25 | 0.22 | 0.22 |
AIRLOOP F4 NE | 0.19 | 0.19 | 0.22 | 0.22 |
AIRLOOP F4 N1 | 0.13 | 0.13 | 0.13 | 0.13 |
AIRLOOP F4 N2 | 0.13 | 0.13 | 0.13 | 0.13 |
AIRLOOP F4 S1 | 0.19 | 0.19 | 0.13 | 0.13 |
AIRLOOP F4 S2 | 0.19 | 0.19 | 0.13 | 0.13 |
AIRLOOP M SW | 0.28 | 0.28 | 0.23 | 0.23 |
AIRLOOP M NW | 0.25 | 0.25 | 0.23 | 0.23 |
AIRLOOP M SE | 0.26 | 0.26 | 0.23 | 0.23 |
AIRLOOP M NE | 0.19 | 0.19 | 0.23 | 0.23 |
AIRLOOP M N1 | 0.14 | 0.14 | 0.13 | 0.13 |
AIRLOOP M N2 | 0.13 | 0.13 | 0.13 | 0.13 |
AIRLOOP M S1 | 0.19 | 0.19 | 0.13 | 0.13 |
AIRLOOP M S2 | 0.19 | 0.19 | 0.13 | 0.13 |
AIRLOOP F6 SW | 0.28 | 0.28 | 0.24 | 0.24 |
AIRLOOP F6 NW | 0.25 | 0.25 | 0.24 | 0.24 |
AIRLOOP F6 SE | 0.25 | 0.25 | 0.24 | 0.24 |
AIRLOOP F6 NE | 0.19 | 0.19 | 0.24 | 0.24 |
AIRLOOP F6 N1 | 0.13 | 0.13 | 0.14 | 0.14 |
AIRLOOP F6 N2 | 0.13 | 0.13 | 0.14 | 0.14 |
AIRLOOP F6 S1 | 0.19 | 0.19 | 0.14 | 0.14 |
AIRLOOP F6 S2 | 0.19 | 0.19 | 0.14 | 0.14 |
AIRLOOP F7 SW | 0.28 | 0.28 | 0.25 | 0.25 |
AIRLOOP F7 NW | 0.25 | 0.25 | 0.25 | 0.25 |
AIRLOOP F7 SE | 0.25 | 0.25 | 0.25 | 0.25 |
AIRLOOP F7 NE | 0.19 | 0.19 | 0.25 | 0.25 |
AIRLOOP F7 N1 | 0.13 | 0.13 | 0.15 | 0.15 |
AIRLOOP F7 N2 | 0.13 | 0.13 | 0.15 | 0.15 |
AIRLOOP F7 S1 | 0.19 | 0.19 | 0.15 | 0.15 |
AIRLOOP F7 S2 | 0.19 | 0.19 | 0.15 | 0.15 |
AIRLOOP F8 SW | 0.28 | 0.28 | 0.26 | 0.26 |
AIRLOOP F8 NW | 0.25 | 0.25 | 0.26 | 0.26 |
AIRLOOP F8 SE | 0.25 | 0.25 | 0.26 | 0.26 |
AIRLOOP F8 NE | 0.19 | 0.19 | 0.26 | 0.26 |
AIRLOOP F8 N1 | 0.13 | 0.13 | 0.15 | 0.15 |
AIRLOOP F8 N2 | 0.13 | 0.13 | 0.15 | 0.15 |
AIRLOOP F8 S1 | 0.19 | 0.19 | 0.15 | 0.15 |
AIRLOOP F8 S2 | 0.19 | 0.19 | 0.15 | 0.15 |
AIRLOOP F9 SW | 0.28 | 0.28 | 0.27 | 0.27 |
AIRLOOP F9 NW | 0.26 | 0.26 | 0.27 | 0.27 |
AIRLOOP F9 SE | 0.26 | 0.26 | 0.27 | 0.27 |
AIRLOOP F9 NE | 0.19 | 0.19 | 0.27 | 0.27 |
AIRLOOP F9 N1 | 0.14 | 0.14 | 0.16 | 0.16 |
AIRLOOP F9 N2 | 0.14 | 0.14 | 0.16 | 0.16 |
AIRLOOP F9 S1 | 0.19 | 0.19 | 0.16 | 0.16 |
AIRLOOP F9 S2 | 0.19 | 0.19 | 0.16 | 0.16 |
AIRLOOP T SW | 0.34 | 0.34 | 0.31 | 0.31 |
AIRLOOP T NW | 0.30 | 0.30 | 0.32 | 0.32 |
AIRLOOP T SE | 0.31 | 0.31 | 0.31 | 0.31 |
AIRLOOP T NE | 0.22 | 0.22 | 0.32 | 0.32 |
AIRLOOP T N1 | 0.16 | 0.16 | 0.21 | 0.21 |
AIRLOOP T N2 | 0.16 | 0.16 | 0.21 | 0.21 |
AIRLOOP T S1 | 0.25 | 0.25 | 0.21 | 0.21 |
AIRLOOP T S2 | 0.25 | 0.25 | 0.21 | 0.21 |
Report: System Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 3678.75 | 7101.75 | 2522.00 |
G NW APARTMENT | 4101.25 | 7524.50 | 3307.00 |
OFFICE | 958.00 | 1262.25 | 202.25 |
G NE APARTMENT | 4089.00 | 7563.25 | 3306.50 |
G N1 APARTMENT | 3303.00 | 7850.75 | 2815.75 |
G N2 APARTMENT | 3295.00 | 7855.25 | 2812.50 |
G S1 APARTMENT | 2785.25 | 7283.75 | 1847.50 |
G S2 APARTMENT | 2787.25 | 7231.75 | 1806.50 |
F2 SW APARTMENT | 3516.00 | 6055.25 | 1502.25 |
F2 NW APARTMENT | 3897.00 | 6713.25 | 2379.75 |
F2 SE APARTMENT | 3558.50 | 5824.25 | 1318.25 |
F2 NE APARTMENT | 3834.50 | 6825.00 | 2425.00 |
F2 N1 APARTMENT | 2764.75 | 7108.00 | 1633.75 |
F2 N2 APARTMENT | 2759.50 | 7119.75 | 1639.50 |
F2 S1 APARTMENT | 2654.50 | 6144.75 | 804.25 |
F2 S2 APARTMENT | 2669.25 | 6108.50 | 791.00 |
F3 SW APARTMENT | 3483.50 | 5938.00 | 1366.25 |
F3 NW APARTMENT | 3873.25 | 6588.50 | 2241.00 |
F3 SE APARTMENT | 3488.75 | 5944.50 | 1346.25 |
F3 NE APARTMENT | 3792.75 | 6696.50 | 2269.50 |
F3 N1 APARTMENT | 2697.50 | 6915.25 | 1407.75 |
F3 N2 APARTMENT | 2692.75 | 6928.75 | 1412.75 |
F3 S1 APARTMENT | 2699.25 | 5902.75 | 664.50 |
F3 S2 APARTMENT | 2708.50 | 5893.75 | 663.00 |
F4 SW APARTMENT | 3505.00 | 5934.00 | 1369.75 |
F4 NW APARTMENT | 3910.75 | 6583.75 | 2266.75 |
F4 SE APARTMENT | 3484.00 | 5983.75 | 1372.00 |
F4 NE APARTMENT | 3841.00 | 6672.75 | 2288.00 |
F4 N1 APARTMENT | 2745.00 | 6873.00 | 1407.75 |
F4 N2 APARTMENT | 2736.00 | 6888.00 | 1411.25 |
F4 S1 APARTMENT | 2728.50 | 5858.25 | 653.50 |
F4 S2 APARTMENT | 2728.00 | 5853.50 | 652.25 |
M SW APARTMENT | 3479.50 | 5967.75 | 1362.25 |
M NW APARTMENT | 3888.50 | 6602.75 | 2253.25 |
M SE APARTMENT | 3446.00 | 6022.75 | 1364.00 |
M NE APARTMENT | 3837.75 | 6684.75 | 2269.75 |
M N1 APARTMENT | 2727.25 | 6865.00 | 1372.00 |
M N2 APARTMENT | 2720.50 | 6882.25 | 1378.50 |
M S1 APARTMENT | 2701.00 | 5875.25 | 637.00 |
M S2 APARTMENT | 2703.00 | 5878.00 | 637.50 |
F6 SW APARTMENT | 3467.50 | 6119.50 | 1472.00 |
F6 NW APARTMENT | 3888.50 | 6749.00 | 2376.00 |
F6 SE APARTMENT | 3427.50 | 6173.50 | 1480.00 |
F6 NE APARTMENT | 3852.75 | 6821.00 | 2398.50 |
F6 N1 APARTMENT | 2732.75 | 7019.75 | 1507.75 |
F6 N2 APARTMENT | 2723.50 | 7020.00 | 1506.50 |
F6 S1 APARTMENT | 2619.50 | 6072.00 | 706.25 |
F6 S2 APARTMENT | 2616.50 | 6071.75 | 706.50 |
F7 SW APARTMENT | 3455.50 | 6236.00 | 1556.25 |
F7 NW APARTMENT | 3880.75 | 6854.25 | 2455.00 |
F7 SE APARTMENT | 3395.00 | 6285.00 | 1555.25 |
F7 NE APARTMENT | 3862.75 | 6918.75 | 2470.00 |
F7 N1 APARTMENT | 2737.25 | 7116.00 | 1580.25 |
F7 N2 APARTMENT | 2731.75 | 7119.25 | 1579.50 |
F7 S1 APARTMENT | 2577.00 | 6209.00 | 752.50 |
F7 S2 APARTMENT | 2574.25 | 6209.50 | 753.25 |
F8 SW APARTMENT | 3438.50 | 6340.25 | 1625.75 |
F8 NW APARTMENT | 3876.75 | 6924.50 | 2512.25 |
F8 SE APARTMENT | 3389.75 | 6367.00 | 1626.00 |
F8 NE APARTMENT | 3875.50 | 6994.50 | 2530.75 |
F8 N1 APARTMENT | 2755.25 | 7192.50 | 1643.25 |
F8 N2 APARTMENT | 2749.25 | 7193.25 | 1644.25 |
F8 S1 APARTMENT | 2539.25 | 6326.25 | 794.25 |
F8 S2 APARTMENT | 2533.75 | 6325.75 | 793.50 |
F9 SW APARTMENT | 3556.00 | 6434.25 | 1836.00 |
F9 NW APARTMENT | 3981.50 | 6990.00 | 2668.00 |
F9 SE APARTMENT | 3502.75 | 6444.50 | 1820.00 |
F9 NE APARTMENT | 3964.50 | 7051.50 | 2668.00 |
F9 N1 APARTMENT | 2947.25 | 7243.50 | 1868.50 |
F9 N2 APARTMENT | 2937.00 | 7243.50 | 1863.00 |
F9 S1 APARTMENT | 2620.50 | 6458.25 | 967.75 |
F9 S2 APARTMENT | 2620.00 | 6456.75 | 967.00 |
T SW APARTMENT | 4338.00 | 6707.75 | 2852.25 |
T NW APARTMENT | 4634.25 | 7234.00 | 3504.50 |
T SE APARTMENT | 4322.50 | 6735.75 | 2859.75 |
T NE APARTMENT | 4638.25 | 7231.25 | 3508.75 |
T N1 APARTMENT | 3932.50 | 7402.75 | 2967.00 |
T N2 APARTMENT | 3930.00 | 7405.75 | 2967.75 |
T S1 APARTMENT | 3596.50 | 6643.00 | 2175.25 |
T S2 APARTMENT | 3597.75 | 6646.50 | 2175.25 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 5990.50 | 8022.25 | 4000.75 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 1.25 | 5.75 | 1.25 | 5.75 |
G NW APARTMENT | 1.00 | 0.75 | 1.00 | 0.75 |
OFFICE | 3.75 | 0.00 | 0.50 | 0.00 |
G NE APARTMENT | 1.00 | 0.00 | 1.00 | 0.00 |
G N1 APARTMENT | 4.75 | 0.00 | 4.75 | 0.00 |
G N2 APARTMENT | 5.25 | 0.00 | 5.25 | 0.00 |
G S1 APARTMENT | 2.75 | 1.75 | 2.75 | 1.75 |
G S2 APARTMENT | 2.50 | 3.00 | 2.50 | 3.00 |
F2 SW APARTMENT | 1.00 | 5.50 | 1.00 | 5.50 |
F2 NW APARTMENT | 1.50 | 7.75 | 1.50 | 7.75 |
F2 SE APARTMENT | 1.75 | 0.25 | 1.75 | 0.25 |
F2 NE APARTMENT | 1.75 | 8.25 | 1.75 | 8.25 |
F2 N1 APARTMENT | 4.50 | 33.50 | 4.50 | 33.50 |
F2 N2 APARTMENT | 2.50 | 35.50 | 2.50 | 35.50 |
F2 S1 APARTMENT | 3.00 | 3.75 | 3.00 | 3.75 |
F2 S2 APARTMENT | 2.75 | 3.50 | 2.75 | 3.50 |
F3 SW APARTMENT | 1.50 | 7.00 | 1.50 | 7.00 |
F3 NW APARTMENT | 0.75 | 10.25 | 0.75 | 10.25 |
F3 SE APARTMENT | 2.50 | 3.25 | 2.50 | 3.25 |
F3 NE APARTMENT | 1.25 | 7.75 | 1.25 | 7.75 |
F3 N1 APARTMENT | 3.00 | 39.00 | 3.00 | 39.00 |
F3 N2 APARTMENT | 2.25 | 42.50 | 2.25 | 42.50 |
F3 S1 APARTMENT | 1.25 | 4.50 | 1.25 | 4.50 |
F3 S2 APARTMENT | 1.50 | 4.00 | 1.50 | 4.00 |
F4 SW APARTMENT | 0.50 | 7.75 | 0.50 | 7.75 |
F4 NW APARTMENT | 1.00 | 10.75 | 1.00 | 10.75 |
F4 SE APARTMENT | 1.75 | 4.00 | 1.75 | 4.00 |
F4 NE APARTMENT | 0.25 | 4.50 | 0.25 | 4.50 |
F4 N1 APARTMENT | 2.75 | 41.50 | 2.75 | 41.50 |
F4 N2 APARTMENT | 2.00 | 44.00 | 2.00 | 44.00 |
F4 S1 APARTMENT | 2.75 | 7.25 | 2.75 | 7.25 |
F4 S2 APARTMENT | 2.75 | 6.25 | 2.75 | 6.25 |
M SW APARTMENT | 1.50 | 8.25 | 1.50 | 8.25 |
M NW APARTMENT | 0.75 | 11.25 | 0.75 | 11.25 |
M SE APARTMENT | 1.25 | 5.00 | 1.25 | 5.00 |
M NE APARTMENT | 0.25 | 3.00 | 0.25 | 3.00 |
M N1 APARTMENT | 3.50 | 42.25 | 3.50 | 42.25 |
M N2 APARTMENT | 3.75 | 44.50 | 3.75 | 44.50 |
M S1 APARTMENT | 2.00 | 8.25 | 2.00 | 8.25 |
M S2 APARTMENT | 3.00 | 6.75 | 3.00 | 6.75 |
F6 SW APARTMENT | 1.00 | 8.50 | 1.00 | 8.50 |
F6 NW APARTMENT | 0.00 | 11.50 | 0.00 | 11.50 |
F6 SE APARTMENT | 0.50 | 5.75 | 0.50 | 5.75 |
F6 NE APARTMENT | 0.00 | 1.50 | 0.00 | 1.50 |
F6 N1 APARTMENT | 3.50 | 30.50 | 3.50 | 30.50 |
F6 N2 APARTMENT | 1.50 | 29.75 | 1.50 | 29.75 |
F6 S1 APARTMENT | 3.00 | 9.00 | 3.00 | 9.00 |
F6 S2 APARTMENT | 2.75 | 7.50 | 2.75 | 7.50 |
F7 SW APARTMENT | 1.00 | 8.75 | 1.00 | 8.75 |
F7 NW APARTMENT | 0.25 | 11.25 | 0.25 | 11.25 |
F7 SE APARTMENT | 0.25 | 6.25 | 0.25 | 6.25 |
F7 NE APARTMENT | 0.25 | 0.75 | 0.25 | 0.75 |
F7 N1 APARTMENT | 2.00 | 21.25 | 2.00 | 21.25 |
F7 N2 APARTMENT | 2.50 | 21.00 | 2.50 | 21.00 |
F7 S1 APARTMENT | 3.75 | 9.75 | 3.75 | 9.75 |
F7 S2 APARTMENT | 3.75 | 7.75 | 3.75 | 7.75 |
F8 SW APARTMENT | 1.00 | 9.00 | 1.00 | 9.00 |
F8 NW APARTMENT | 0.50 | 7.75 | 0.50 | 7.75 |
F8 SE APARTMENT | 1.25 | 5.25 | 1.25 | 5.25 |
F8 NE APARTMENT | 0.25 | 0.50 | 0.25 | 0.50 |
F8 N1 APARTMENT | 1.50 | 17.25 | 1.50 | 17.25 |
F8 N2 APARTMENT | 2.25 | 16.50 | 2.25 | 16.50 |
F8 S1 APARTMENT | 2.25 | 9.25 | 2.25 | 9.25 |
F8 S2 APARTMENT | 3.50 | 7.50 | 3.50 | 7.50 |
F9 SW APARTMENT | 0.50 | 9.00 | 0.50 | 9.00 |
F9 NW APARTMENT | 0.00 | 6.00 | 0.00 | 6.00 |
F9 SE APARTMENT | 0.50 | 2.00 | 0.50 | 2.00 |
F9 NE APARTMENT | 0.25 | 0.00 | 0.25 | 0.00 |
F9 N1 APARTMENT | 1.75 | 11.25 | 1.75 | 11.25 |
F9 N2 APARTMENT | 2.00 | 9.75 | 2.00 | 9.75 |
F9 S1 APARTMENT | 1.50 | 8.50 | 1.50 | 8.50 |
F9 S2 APARTMENT | 2.25 | 8.50 | 2.25 | 8.50 |
T SW APARTMENT | 0.25 | 6.75 | 0.25 | 6.75 |
T NW APARTMENT | 0.00 | 6.75 | 0.00 | 6.75 |
T SE APARTMENT | 0.50 | 4.00 | 0.50 | 4.00 |
T NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 1.25 | 1.00 | 1.25 | 1.00 |
T N2 APARTMENT | 0.50 | 1.00 | 0.50 | 1.00 |
T S1 APARTMENT | 1.25 | 1.50 | 1.25 | 1.50 |
T S2 APARTMENT | 1.00 | 1.50 | 1.00 | 1.50 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 111.75 | 51.75 | 109.00 | 51.75 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.215 | 0.000 | 0.259 |
G NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.215 | 0.000 | 0.251 |
OFFICE | 0.94 | 1.00 | 268.96 | 0.519 | 0.241 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.215 | 0.000 | 0.252 |
G N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.130 | 0.000 | 0.246 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.129 | 0.000 | 0.246 |
G S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.130 | 0.000 | 0.257 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.130 | 0.000 | 0.257 |
F2 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.309 | 0.000 | 0.304 |
F2 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.309 | 0.000 | 0.292 |
F2 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.309 | 0.000 | 0.305 |
F2 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.309 | 0.000 | 0.292 |
F2 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.186 | 0.000 | 0.287 |
F2 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.186 | 0.000 | 0.287 |
F2 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.186 | 0.000 | 0.302 |
F2 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.186 | 0.000 | 0.302 |
F3 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.366 | 0.000 | 0.330 |
F3 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.366 | 0.000 | 0.317 |
F3 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.366 | 0.000 | 0.331 |
F3 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.365 | 0.000 | 0.317 |
F3 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.220 | 0.000 | 0.313 |
F3 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.220 | 0.000 | 0.313 |
F3 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.221 | 0.000 | 0.329 |
F3 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.221 | 0.000 | 0.329 |
F4 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.409 | 0.000 | 0.337 |
F4 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.408 | 0.000 | 0.323 |
F4 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.409 | 0.000 | 0.337 |
F4 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.408 | 0.000 | 0.323 |
F4 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.246 | 0.000 | 0.319 |
F4 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.246 | 0.000 | 0.319 |
F4 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.247 | 0.000 | 0.336 |
F4 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.247 | 0.000 | 0.336 |
M SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.444 | 0.000 | 0.353 |
M NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.444 | 0.000 | 0.338 |
M SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.444 | 0.000 | 0.354 |
M NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.444 | 0.000 | 0.338 |
M N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.268 | 0.000 | 0.335 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.268 | 0.000 | 0.335 |
M S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.268 | 0.000 | 0.352 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.268 | 0.000 | 0.352 |
F6 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.474 | 0.000 | 0.367 |
F6 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.474 | 0.000 | 0.351 |
F6 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.474 | 0.000 | 0.368 |
F6 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.474 | 0.000 | 0.351 |
F6 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.286 | 0.000 | 0.348 |
F6 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.286 | 0.000 | 0.348 |
F6 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.286 | 0.000 | 0.366 |
F6 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.286 | 0.000 | 0.366 |
F7 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.501 | 0.000 | 0.379 |
F7 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.501 | 0.000 | 0.361 |
F7 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.501 | 0.000 | 0.379 |
F7 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.501 | 0.000 | 0.362 |
F7 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.302 | 0.000 | 0.358 |
F7 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.302 | 0.000 | 0.358 |
F7 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.302 | 0.000 | 0.378 |
F7 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.302 | 0.000 | 0.378 |
F8 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.526 | 0.000 | 0.391 |
F8 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.525 | 0.000 | 0.372 |
F8 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.526 | 0.000 | 0.391 |
F8 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.525 | 0.000 | 0.373 |
F8 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.317 | 0.000 | 0.369 |
F8 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.317 | 0.000 | 0.369 |
F8 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.317 | 0.000 | 0.389 |
F8 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.317 | 0.000 | 0.390 |
F9 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.548 | 0.000 | 0.402 |
F9 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.547 | 0.000 | 0.382 |
F9 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.548 | 0.000 | 0.402 |
F9 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.547 | 0.000 | 0.383 |
F9 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.330 | 0.000 | 0.379 |
F9 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.330 | 0.000 | 0.379 |
F9 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.330 | 0.000 | 0.400 |
F9 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.330 | 0.000 | 0.400 |
T SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.568 | 0.000 | 0.409 |
T NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.568 | 0.000 | 0.389 |
T SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.568 | 0.000 | 0.410 |
T NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.568 | 0.000 | 0.391 |
T N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.342 | 0.000 | 0.387 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.342 | 0.000 | 0.387 |
T S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.343 | 0.000 | 0.408 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.343 | 0.000 | 0.408 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.96 | 0.500 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Surfaces by ClassTotal | Outdoors | |
Wall | 420 | 140 |
Floor | 90 | 9 |
Roof | 90 | 9 |
Internal Mass | 80 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 140 | 140 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 80 |
Conditioned Zones | 80 |
Unconditioned Zones | 10 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 4156 |
Defaulted Fields | 814 |
Fields with Defaults | 11184 |
Autosized Fields | 1293 |
Autosizable Fields | 1630 |
Autocalculated Fields | 907 |
Autocalculatable Fields | 1710 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 3048.54 | 54731.34 | 17-MAY-04:45 | 290808.57 | 11-JAN-12:00 |
Electricity:Building | 1433.88 | 25760.85 | 01-JAN-03:15 | 70162.48 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity | 296.56 | 6715.87 | 01-JAN-00:15 | 14401.37 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 242.55 | 5824.91 | 01-JAN-00:15 | 11484.27 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 39.38 | 663.42 | 01-JAN-00:15 | 2934.49 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 29.88 | 469.18 | 01-JAN-00:15 | 2345.88 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F2 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F2 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F3 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F3 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F4 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F4 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:M SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M CORRIDOR | 32.88 | 1042.61 | 01-JAN-00:15 | 1042.61 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 32.88 | 1042.61 | 01-JAN-00:15 | 1042.61 | 01-JAN-00:15 |
Electricity:Zone:F6 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F6 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F7 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F7 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F8 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F8 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F9 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F9 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:T SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T CORRIDOR | 179.47 | 1701.70 | 01-JAN-00:15 | 10868.20 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 54.01 | 890.97 | 01-JAN-00:15 | 2917.11 | 01-JAN-19:15 |
InteriorEquipment:Electricity | 1137.32 | 19044.98 | 01-JAN-03:15 | 57142.09 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 1137.32 | 19044.98 | 01-JAN-03:15 | 57142.09 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 9.50 | 194.24 | 01-JAN-00:15 | 588.62 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T CORRIDOR | 163.03 | 1180.40 | 01-JAN-00:15 | 10346.90 | 01-JAN-07:15 |
Fans:Electricity | 631.26 | 20017.05 | 01-JAN-05:30 | 20017.05 | 01-JAN-00:15 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Electricity:HVAC | 1379.81 | 20678.30 | 23-MAY-02:15 | 243201.16 | 11-JAN-12:00 |
ElectricityProduced:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityProduced:HVAC | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricityProduced | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 3048.54 | 54731.34 | 17-MAY-04:45 | 290808.57 | 11-JAN-12:00 |
ElectricityPurchased:Plant | 3048.54 | 54731.34 | 17-MAY-04:45 | 290808.57 | 11-JAN-12:00 |
Cogeneration:ElectricityPurchased | 3048.54 | 54731.34 | 17-MAY-04:45 | 290808.57 | 11-JAN-12:00 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 3048.54 | 54731.34 | 17-MAY-04:45 | 290808.57 | 11-JAN-12:00 |
ElectricityNet:Plant | 3048.54 | 54731.34 | 17-MAY-04:45 | 290808.57 | 11-JAN-12:00 |
Cogeneration:ElectricityNet | 3048.54 | 54731.34 | 17-MAY-04:45 | 290808.57 | 11-JAN-12:00 |
ExteriorLights:Electricity | 162.58 | 0.00 | 01-JAN-08:15 | 10364.00 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 162.58 | 0.00 | 01-JAN-08:15 | 10364.00 | 01-JAN-00:15 |
General:Fans:Electricity | 631.26 | 20017.05 | 01-JAN-05:30 | 20017.05 | 01-JAN-00:15 |
Cooling:Electricity | 144.53 | 0.00 | 01-JAN-00:15 | 77053.22 | 16-JUL-16:15 |
Heating:Electricity | 567.85 | 0.00 | 30-MAR-16:30 | 222302.08 | 19-DEC-03:00 |
Electricity:Plant | 72.26 | 36.93 | 13-APR-16:15 | 5333.81 | 16-JUL-16:00 |
HeatRejection:Electricity | 6.37 | 0.00 | 01-JAN-00:15 | 3187.96 | 16-JUL-16:00 |
Boiler Parasitic:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Pumps:Electricity | 65.89 | 36.93 | 13-APR-16:15 | 2145.84 | 01-JAN-00:15 |
WIRED_LTG_ELECTRICITY | 0.44 | 0.00 | 01-JAN-00:15 | 21.60 | 01-JAN-19:30 |
WIRED_INT_EQUIP | 979.40 | 1018.50 | 01-JAN-00:15 | 10185.00 | 01-JAN-07:15 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 3524.24 | 2357.00 | 10-MAR-23:45 | 415921.91 | 09-JAN-07:30 |
Gas:Plant | 3524.24 | 2357.00 | 10-MAR-23:45 | 415921.91 | 09-JAN-07:30 |
WaterSystems:Gas | 1343.09 | 2357.00 | 01-JAN-00:15 | 88770.21 | 27-FEB-08:00 |
Water Heater:WaterSystems:Gas | 1343.09 | 2357.00 | 01-JAN-00:15 | 88770.21 | 27-FEB-08:00 |
Heating:Gas | 2181.16 | 0.00 | 10-MAR-12:45 | 330775.49 | 09-JAN-06:00 |
Boiler:Heating:Gas | 2181.16 | 0.00 | 10-MAR-12:45 | 330775.49 | 09-JAN-06:00 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
PlantLoopCoolingDemand:Facility | 594.14 | 0.00 | 01-JAN-00:15 | 371521.75 | 29-JUN-19:00 |
PlantLoopCoolingDemand:HVAC | 594.14 | 0.00 | 01-JAN-00:15 | 371521.75 | 29-JUN-19:00 |
CoolingCoils:PlantLoopCoolingDemand | 594.14 | 0.00 | 01-JAN-00:15 | 371521.75 | 29-JUN-19:00 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 5231.00 | 0.00 | 01-JAN-02:15 | 0.00 | 25-JUN-17:30 |
Water:Plant | 5231.00 | 0.00 | 01-JAN-02:15 | 0.00 | 25-JUN-17:30 |
WaterSystems:Water | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:Water | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
MainsWater:Facility | 5231.00 | 0.00 | 01-JAN-02:15 | 0.00 | 25-JUN-17:30 |
MainsWater:Plant | 5231.00 | 0.00 | 01-JAN-02:15 | 0.00 | 25-JUN-17:30 |
WaterSystems:MainsWater | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:MainsWater | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
sub cat:WaterSystems:Water | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
sub cat:WaterSystems:MainsWater | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
HeatRejection:Water | 452.49 | 0.00 | 01-JAN-00:15 | 0.00 | 17-JUL-14:00 |
HeatRejection:MainsWater | 452.49 | 0.00 | 01-JAN-00:15 | 0.00 | 17-JUL-14:00 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 2728.30 | 558.87 | 17-AUG-01:30 | 316021.09 | 09-JAN-07:15 |
PlantLoopHeatingDemand:Plant | 1048.01 | 558.87 | 17-AUG-01:30 | 69924.82 | 25-FEB-07:45 |
WaterSystems:PlantLoopHeatingDemand | 1048.01 | 558.87 | 17-AUG-01:30 | 69924.82 | 25-FEB-07:45 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 7255.99 | 4984.35 | 29-MAY-03:00 | 1130793.34 | 11-JAN-12:00 |
EnergyTransfer:Building | 1902.33 | 2633.87 | 10-MAY-21:15 | 381169.56 | 11-JAN-12:00 |
EnergyTransfer:Zone:G SW APARTMENT | 21.20 | 0.01 | 18-APR-20:45 | 3771.57 | 11-JAN-12:00 |
Heating:EnergyTransfer | 1490.71 | 0.00 | 10-MAR-14:00 | 381169.56 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 16.92 | 0.00 | 02-JAN-13:15 | 3771.57 | 11-JAN-12:00 |
Cooling:EnergyTransfer | 411.62 | 0.00 | 01-JAN-00:15 | 168932.87 | 17-JUL-14:15 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 4.28 | 0.00 | 01-JAN-00:15 | 2269.24 | 25-AUG-16:15 |
EnergyTransfer:Zone:G NW APARTMENT | 24.39 | 0.07 | 28-APR-23:00 | 3889.08 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 21.76 | 0.00 | 09-FEB-16:15 | 3889.08 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 2.63 | 0.00 | 01-JAN-00:15 | 2035.85 | 06-JUL-17:45 |
EnergyTransfer:Zone:OFFICE | 25.14 | 0.14 | 26-MAY-02:45 | 3528.71 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:OFFICE | 13.45 | 0.00 | 02-JAN-09:30 | 3528.71 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:OFFICE | 11.69 | 0.00 | 01-JAN-00:15 | 3427.73 | 17-JUL-13:45 |
EnergyTransfer:Zone:G NE APARTMENT | 23.98 | 0.08 | 31-MAR-13:30 | 3851.85 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 21.65 | 0.00 | 10-MAR-13:30 | 3851.85 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 2.33 | 0.00 | 01-JAN-00:15 | 1667.23 | 26-JUN-09:30 |
EnergyTransfer:Zone:G N1 APARTMENT | 15.61 | 0.00 | 18-AUG-18:30 | 2549.11 | 08-JAN-08:30 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 13.34 | 0.00 | 10-MAR-14:00 | 2549.11 | 08-JAN-08:30 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 2.26 | 0.00 | 01-JAN-00:15 | 1213.09 | 29-JUN-18:30 |
EnergyTransfer:Zone:G N2 APARTMENT | 15.60 | 0.07 | 10-MAY-23:00 | 2546.65 | 08-JAN-08:30 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 13.34 | 0.00 | 10-MAR-14:00 | 2546.65 | 08-JAN-08:30 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 2.26 | 0.00 | 01-JAN-00:15 | 1201.44 | 29-JUN-18:30 |
EnergyTransfer:Zone:G S1 APARTMENT | 12.81 | 0.01 | 28-MAY-13:45 | 2319.73 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 8.56 | 0.00 | 02-JAN-11:00 | 2319.73 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 4.24 | 0.00 | 01-JAN-00:15 | 1582.41 | 11-AUG-12:45 |
EnergyTransfer:Zone:G S2 APARTMENT | 12.74 | 0.01 | 19-MAY-07:00 | 2278.68 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 8.31 | 0.00 | 02-JAN-11:00 | 2278.68 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 4.43 | 0.00 | 01-JAN-00:15 | 1583.89 | 11-AUG-12:45 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F2 SW APARTMENT | 23.32 | 0.02 | 29-SEP-24:00 | 4550.58 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:F2 SW APARTMENT | 16.06 | 0.00 | 02-JAN-13:00 | 4550.58 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT | 7.26 | 0.00 | 01-JAN-00:15 | 2964.17 | 25-AUG-16:15 |
EnergyTransfer:Zone:F2 NW APARTMENT | 26.25 | 0.01 | 14-APR-20:15 | 4730.14 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:F2 NW APARTMENT | 21.88 | 0.00 | 09-FEB-15:30 | 4730.14 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT | 4.38 | 0.00 | 01-JAN-00:15 | 2647.40 | 19-JUL-17:30 |
EnergyTransfer:Zone:F2 SE APARTMENT | 22.82 | 0.06 | 17-AUG-20:30 | 4475.16 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:F2 SE APARTMENT | 14.96 | 0.00 | 02-JAN-12:15 | 4475.16 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT | 7.86 | 0.00 | 01-JAN-00:15 | 2905.07 | 17-JUL-12:00 |
EnergyTransfer:Zone:F2 NE APARTMENT | 25.91 | 0.20 | 19-SEP-02:00 | 4728.13 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:F2 NE APARTMENT | 21.69 | 0.00 | 10-MAR-10:15 | 4728.13 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT | 4.23 | 0.00 | 01-JAN-00:15 | 2216.05 | 17-JUL-10:15 |
EnergyTransfer:Zone:F2 N1 APARTMENT | 15.00 | 0.01 | 19-MAY-10:30 | 2786.02 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT | 11.12 | 0.00 | 09-FEB-17:15 | 2786.02 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT | 3.89 | 0.00 | 01-JAN-00:15 | 1405.85 | 19-JUL-17:30 |
EnergyTransfer:Zone:F2 N2 APARTMENT | 14.99 | 0.06 | 18-SEP-10:45 | 2786.36 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT | 11.12 | 0.00 | 09-FEB-17:15 | 2786.36 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT | 3.88 | 0.00 | 01-JAN-00:15 | 1395.30 | 19-JUL-17:15 |
EnergyTransfer:Zone:F2 S1 APARTMENT | 13.63 | 0.04 | 10-MAY-15:30 | 2591.93 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT | 6.47 | 0.00 | 02-JAN-10:30 | 2591.93 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT | 7.17 | 0.00 | 01-JAN-00:15 | 2045.06 | 11-AUG-12:45 |
EnergyTransfer:Zone:F2 S2 APARTMENT | 13.66 | 0.03 | 21-OCT-04:30 | 2586.96 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT | 6.42 | 0.00 | 02-JAN-10:30 | 2586.96 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT | 7.25 | 0.00 | 01-JAN-00:15 | 2071.53 | 11-AUG-12:45 |
EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F3 SW APARTMENT | 24.74 | 0.00 | 23-AUG-03:15 | 5067.16 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F3 SW APARTMENT | 17.18 | 0.00 | 02-JAN-13:15 | 5067.16 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT | 7.56 | 0.00 | 01-JAN-00:15 | 3109.01 | 18-MAY-18:00 |
EnergyTransfer:Zone:F3 NW APARTMENT | 27.77 | 0.04 | 22-SEP-12:45 | 5194.65 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F3 NW APARTMENT | 23.11 | 0.00 | 09-FEB-15:30 | 5194.65 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT | 4.66 | 0.00 | 01-JAN-00:15 | 2814.58 | 18-MAY-18:00 |
EnergyTransfer:Zone:F3 SE APARTMENT | 24.26 | 0.16 | 09-OCT-18:15 | 5015.50 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F3 SE APARTMENT | 16.88 | 0.00 | 02-JAN-13:15 | 5015.50 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT | 7.38 | 0.00 | 01-JAN-00:15 | 2852.79 | 17-JUL-12:00 |
EnergyTransfer:Zone:F3 NE APARTMENT | 27.40 | 0.12 | 19-SEP-03:30 | 5181.80 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:F3 NE APARTMENT | 22.93 | 0.00 | 10-MAR-10:15 | 5181.80 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT | 4.47 | 0.00 | 01-JAN-00:15 | 2297.33 | 17-JUL-09:45 |
EnergyTransfer:Zone:F3 N1 APARTMENT | 15.60 | 0.02 | 24-JUL-13:00 | 3017.47 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT | 11.34 | 0.00 | 09-FEB-16:30 | 3017.47 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT | 4.26 | 0.00 | 01-JAN-00:15 | 1475.13 | 19-JUL-17:15 |
EnergyTransfer:Zone:F3 N2 APARTMENT | 15.59 | 0.00 | 21-MAY-15:00 | 3017.72 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT | 11.34 | 0.00 | 09-FEB-16:30 | 3017.72 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT | 4.25 | 0.00 | 01-JAN-00:15 | 1464.47 | 19-JUL-17:15 |
EnergyTransfer:Zone:F3 S1 APARTMENT | 14.45 | 0.02 | 28-APR-14:00 | 2863.42 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT | 6.68 | 0.00 | 02-JAN-10:30 | 2863.42 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT | 7.78 | 0.00 | 01-JAN-00:15 | 2114.35 | 19-JUL-14:00 |
EnergyTransfer:Zone:F3 S2 APARTMENT | 14.46 | 0.00 | 11-JUL-18:45 | 2861.41 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT | 6.67 | 0.00 | 02-JAN-10:30 | 2861.41 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT | 7.79 | 0.00 | 01-JAN-00:15 | 2122.81 | 19-JUL-14:00 |
EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F4 SW APARTMENT | 26.15 | 0.04 | 26-SEP-14:15 | 5535.23 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F4 SW APARTMENT | 18.75 | 0.00 | 02-JAN-13:45 | 5535.23 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT | 7.40 | 0.00 | 01-JAN-00:15 | 3162.33 | 18-MAY-18:00 |
EnergyTransfer:Zone:F4 NW APARTMENT | 29.42 | 0.01 | 15-JUN-02:30 | 5662.05 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F4 NW APARTMENT | 24.80 | 0.00 | 09-FEB-16:15 | 5662.05 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT | 4.63 | 0.00 | 01-JAN-00:15 | 2877.04 | 18-MAY-18:00 |
EnergyTransfer:Zone:F4 SE APARTMENT | 25.65 | 0.01 | 10-SEP-10:45 | 5489.06 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F4 SE APARTMENT | 18.57 | 0.00 | 20-JAN-11:45 | 5489.06 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT | 7.09 | 0.00 | 01-JAN-00:15 | 2873.70 | 17-JUL-11:45 |
EnergyTransfer:Zone:F4 NE APARTMENT | 29.01 | 0.06 | 21-APR-11:00 | 5614.42 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F4 NE APARTMENT | 24.62 | 0.00 | 10-MAR-10:30 | 5614.42 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT | 4.39 | 0.00 | 01-JAN-00:15 | 2298.11 | 17-JUL-09:15 |
EnergyTransfer:Zone:F4 N1 APARTMENT | 16.47 | 0.00 | 29-APR-06:30 | 3265.61 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT | 12.17 | 0.00 | 09-FEB-16:30 | 3265.61 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT | 4.31 | 0.00 | 01-JAN-00:15 | 1513.67 | 18-MAY-18:00 |
EnergyTransfer:Zone:F4 N2 APARTMENT | 16.46 | 0.01 | 19-SEP-09:30 | 3264.33 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT | 12.17 | 0.00 | 09-FEB-16:30 | 3264.33 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT | 4.30 | 0.00 | 01-JAN-00:15 | 1493.48 | 18-MAY-18:00 |
EnergyTransfer:Zone:F4 S1 APARTMENT | 15.12 | 0.04 | 20-JUN-08:15 | 3135.93 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT | 7.38 | 0.00 | 02-JAN-10:45 | 3135.93 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT | 7.75 | 0.00 | 01-JAN-00:15 | 2155.35 | 19-JUL-14:00 |
EnergyTransfer:Zone:F4 S2 APARTMENT | 15.11 | 0.03 | 17-JUN-09:45 | 3134.54 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT | 7.37 | 0.00 | 02-JAN-10:45 | 3134.54 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT | 7.73 | 0.00 | 01-JAN-00:15 | 2162.91 | 19-JUL-14:00 |
EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M SW APARTMENT | 27.25 | 0.04 | 10-SEP-22:45 | 5913.23 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 20.04 | 0.00 | 02-JAN-14:15 | 5913.23 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 7.22 | 0.00 | 01-JAN-00:15 | 3205.91 | 18-MAY-18:00 |
EnergyTransfer:Zone:M NW APARTMENT | 30.71 | 0.07 | 01-OCT-19:15 | 6037.69 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 26.13 | 0.00 | 09-FEB-16:15 | 6037.69 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 4.57 | 0.00 | 01-JAN-00:15 | 2921.77 | 18-MAY-18:00 |
EnergyTransfer:Zone:M SE APARTMENT | 26.75 | 0.06 | 08-AUG-02:15 | 5867.16 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 19.87 | 0.00 | 20-JAN-12:00 | 5867.16 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 6.88 | 0.00 | 01-JAN-00:15 | 2915.63 | 17-JUL-11:45 |
EnergyTransfer:Zone:M NE APARTMENT | 30.27 | 0.04 | 02-MAY-17:00 | 5989.45 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 25.95 | 0.00 | 10-MAR-10:45 | 5989.45 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 4.32 | 0.00 | 01-JAN-00:15 | 2315.39 | 17-JUL-09:15 |
EnergyTransfer:Zone:M N1 APARTMENT | 17.13 | 0.01 | 29-JUL-16:45 | 3482.96 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 12.81 | 0.00 | 09-FEB-16:30 | 3482.96 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 4.33 | 0.00 | 01-JAN-00:15 | 1564.53 | 18-MAY-18:00 |
EnergyTransfer:Zone:M N2 APARTMENT | 17.11 | 0.00 | 14-SEP-17:00 | 3481.68 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 12.80 | 0.00 | 09-FEB-16:30 | 3481.68 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 4.31 | 0.00 | 01-JAN-00:15 | 1544.71 | 18-MAY-18:00 |
EnergyTransfer:Zone:M S1 APARTMENT | 15.59 | 0.06 | 20-JUL-10:00 | 3355.67 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 7.96 | 0.00 | 02-JAN-10:45 | 3355.67 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 7.64 | 0.00 | 01-JAN-00:15 | 2204.86 | 19-JUL-14:00 |
EnergyTransfer:Zone:M S2 APARTMENT | 15.58 | 0.00 | 21-MAY-13:30 | 3354.38 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 7.96 | 0.00 | 02-JAN-10:45 | 3354.38 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 7.62 | 0.00 | 01-JAN-00:15 | 2212.30 | 19-JUL-14:00 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F6 SW APARTMENT | 28.45 | 0.08 | 28-JUL-08:30 | 6290.25 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F6 SW APARTMENT | 21.88 | 0.00 | 29-JAN-14:45 | 6290.25 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT | 6.57 | 0.00 | 01-JAN-00:15 | 3180.06 | 18-MAY-18:00 |
EnergyTransfer:Zone:F6 NW APARTMENT | 32.31 | 0.02 | 03-OCT-14:00 | 6414.50 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F6 NW APARTMENT | 28.15 | 0.00 | 09-FEB-16:15 | 6414.50 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT | 4.16 | 0.00 | 01-JAN-00:15 | 2888.82 | 18-MAY-18:00 |
EnergyTransfer:Zone:F6 SE APARTMENT | 27.96 | 0.01 | 12-AUG-18:00 | 6243.64 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F6 SE APARTMENT | 21.71 | 0.00 | 01-FEB-12:15 | 6243.64 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT | 6.25 | 0.00 | 01-JAN-00:15 | 2895.29 | 17-JUL-11:45 |
EnergyTransfer:Zone:F6 NE APARTMENT | 31.86 | 0.05 | 26-SEP-15:45 | 6365.57 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F6 NE APARTMENT | 27.99 | 0.00 | 10-MAR-11:00 | 6365.57 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT | 3.87 | 0.00 | 01-JAN-00:15 | 2333.27 | 17-JUL-07:45 |
EnergyTransfer:Zone:F6 N1 APARTMENT | 18.00 | 0.03 | 07-JUN-18:45 | 3721.45 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT | 14.10 | 0.00 | 09-FEB-17:00 | 3721.45 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT | 3.90 | 0.00 | 01-JAN-00:15 | 1538.18 | 18-MAY-18:00 |
EnergyTransfer:Zone:F6 N2 APARTMENT | 17.98 | 0.01 | 23-AUG-12:30 | 3720.15 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT | 14.10 | 0.00 | 09-FEB-17:00 | 3720.15 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT | 3.88 | 0.00 | 01-JAN-00:15 | 1519.11 | 18-MAY-18:00 |
EnergyTransfer:Zone:F6 S1 APARTMENT | 15.91 | 0.00 | 02-OCT-14:45 | 3594.24 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT | 8.97 | 0.00 | 02-JAN-11:00 | 3594.24 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT | 6.94 | 0.00 | 01-JAN-00:15 | 2190.73 | 19-JUL-14:00 |
EnergyTransfer:Zone:F6 S2 APARTMENT | 15.89 | 0.10 | 31-JAN-18:00 | 3592.96 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT | 8.97 | 0.00 | 02-JAN-11:00 | 3592.96 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT | 6.92 | 0.00 | 01-JAN-00:15 | 2198.21 | 19-JUL-14:00 |
EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F7 SW APARTMENT | 29.53 | 0.00 | 03-JUL-15:45 | 6610.35 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F7 SW APARTMENT | 23.39 | 0.00 | 01-FEB-12:30 | 6610.35 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT | 6.13 | 0.00 | 01-JAN-00:15 | 3170.86 | 18-MAY-18:00 |
EnergyTransfer:Zone:F7 NW APARTMENT | 33.64 | 0.01 | 15-JUN-01:30 | 6733.10 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F7 NW APARTMENT | 29.75 | 0.00 | 09-FEB-16:30 | 6733.10 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT | 3.90 | 0.00 | 01-JAN-00:15 | 2874.44 | 18-MAY-18:00 |
EnergyTransfer:Zone:F7 SE APARTMENT | 29.04 | 0.00 | 17-AUG-04:45 | 6563.35 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F7 SE APARTMENT | 23.21 | 0.00 | 01-FEB-12:30 | 6563.35 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT | 5.82 | 0.00 | 01-JAN-00:15 | 2894.01 | 17-JUL-11:45 |
EnergyTransfer:Zone:F7 NE APARTMENT | 33.18 | 0.03 | 03-JUN-15:30 | 6683.68 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F7 NE APARTMENT | 29.60 | 0.00 | 10-MAR-12:45 | 6683.68 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT | 3.59 | 0.00 | 01-JAN-00:15 | 2341.21 | 17-JUL-07:45 |
EnergyTransfer:Zone:F7 N1 APARTMENT | 18.73 | 0.00 | 05-NOV-05:15 | 3918.98 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT | 15.10 | 0.00 | 09-FEB-17:15 | 3918.98 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT | 3.63 | 0.00 | 01-JAN-00:15 | 1556.21 | 26-MAY-15:45 |
EnergyTransfer:Zone:F7 N2 APARTMENT | 18.72 | 0.06 | 17-JUN-11:00 | 3917.68 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT | 15.10 | 0.00 | 09-FEB-17:15 | 3917.68 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT | 3.62 | 0.00 | 01-JAN-00:15 | 1555.37 | 26-MAY-15:45 |
EnergyTransfer:Zone:F7 S1 APARTMENT | 16.27 | 0.14 | 26-NOV-15:30 | 3793.73 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT | 9.80 | 0.00 | 02-JAN-11:15 | 3793.73 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT | 6.46 | 0.00 | 01-JAN-00:15 | 2194.35 | 19-JUL-14:00 |
EnergyTransfer:Zone:F7 S2 APARTMENT | 16.25 | 0.05 | 11-OCT-14:00 | 3792.45 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT | 9.80 | 0.00 | 02-JAN-11:15 | 3792.45 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT | 6.45 | 0.00 | 01-JAN-00:15 | 2201.88 | 19-JUL-14:00 |
EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F8 SW APARTMENT | 30.62 | 0.02 | 11-SEP-06:45 | 6904.65 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F8 SW APARTMENT | 24.83 | 0.00 | 01-FEB-12:45 | 6904.65 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT | 5.79 | 0.00 | 01-JAN-00:15 | 3169.04 | 18-MAY-18:00 |
EnergyTransfer:Zone:F8 NW APARTMENT | 34.96 | 0.02 | 12-SEP-13:45 | 7025.15 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F8 NW APARTMENT | 31.28 | 0.00 | 09-FEB-16:30 | 7025.15 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT | 3.68 | 0.00 | 01-JAN-00:15 | 2872.97 | 18-MAY-18:00 |
EnergyTransfer:Zone:F8 SE APARTMENT | 30.14 | 0.00 | 10-OCT-01:30 | 6857.35 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F8 SE APARTMENT | 24.65 | 0.00 | 01-FEB-12:30 | 6857.35 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT | 5.48 | 0.00 | 01-JAN-00:15 | 2923.67 | 17-JUL-12:00 |
EnergyTransfer:Zone:F8 NE APARTMENT | 34.50 | 0.00 | 10-SEP-17:00 | 6975.41 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F8 NE APARTMENT | 31.12 | 0.00 | 10-MAR-13:00 | 6975.41 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT | 3.38 | 0.00 | 01-JAN-00:15 | 2362.37 | 17-JUL-19:00 |
EnergyTransfer:Zone:F8 N1 APARTMENT | 19.50 | 0.00 | 27-AUG-16:00 | 4102.07 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT | 16.07 | 0.00 | 09-FEB-17:15 | 4102.07 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT | 3.43 | 0.00 | 01-JAN-00:15 | 1620.61 | 28-JUN-18:15 |
EnergyTransfer:Zone:F8 N2 APARTMENT | 19.49 | 0.00 | 12-AUG-05:45 | 4100.78 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT | 16.07 | 0.00 | 11-FEB-20:15 | 4100.78 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT | 3.42 | 0.00 | 01-JAN-00:15 | 1620.84 | 28-JUN-18:15 |
EnergyTransfer:Zone:F8 S1 APARTMENT | 16.72 | 0.05 | 05-APR-07:00 | 3980.00 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT | 10.63 | 0.00 | 02-JAN-11:30 | 3980.00 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT | 6.08 | 0.00 | 01-JAN-00:15 | 2205.14 | 19-JUL-14:00 |
EnergyTransfer:Zone:F8 S2 APARTMENT | 16.70 | 0.06 | 28-AUG-20:45 | 3978.74 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT | 10.63 | 0.00 | 02-JAN-11:30 | 3978.74 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT | 6.07 | 0.00 | 01-JAN-00:15 | 2212.75 | 19-JUL-14:00 |
EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F9 SW APARTMENT | 32.68 | 0.03 | 16-SEP-01:30 | 7259.87 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F9 SW APARTMENT | 27.17 | 0.00 | 01-FEB-12:45 | 7259.87 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT | 5.51 | 0.00 | 01-JAN-00:15 | 3311.15 | 18-MAY-17:45 |
EnergyTransfer:Zone:F9 NW APARTMENT | 37.30 | 0.00 | 13-AUG-04:45 | 7377.42 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F9 NW APARTMENT | 33.77 | 0.00 | 09-FEB-17:00 | 7377.42 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT | 3.54 | 0.00 | 01-JAN-00:15 | 2973.07 | 18-MAY-17:45 |
EnergyTransfer:Zone:F9 SE APARTMENT | 32.16 | 0.00 | 28-AUG-09:15 | 7210.53 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F9 SE APARTMENT | 27.00 | 0.00 | 01-FEB-12:30 | 7210.53 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT | 5.16 | 0.00 | 01-JAN-00:15 | 3005.62 | 17-JUL-12:00 |
EnergyTransfer:Zone:F9 NE APARTMENT | 36.83 | 0.01 | 15-MAY-17:00 | 7325.57 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F9 NE APARTMENT | 33.59 | 0.00 | 10-MAR-13:15 | 7325.57 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT | 3.24 | 0.00 | 01-JAN-00:15 | 2470.63 | 17-JUL-18:45 |
EnergyTransfer:Zone:F9 N1 APARTMENT | 21.18 | 0.01 | 11-JUN-19:00 | 4347.02 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT | 17.93 | 0.00 | 11-FEB-20:00 | 4347.02 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT | 3.25 | 0.00 | 01-JAN-00:15 | 1743.81 | 28-JUN-18:15 |
EnergyTransfer:Zone:F9 N2 APARTMENT | 21.17 | 0.00 | 26-MAY-10:00 | 4345.66 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT | 17.92 | 0.00 | 11-FEB-20:30 | 4345.66 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT | 3.25 | 0.00 | 01-JAN-00:15 | 1744.01 | 28-JUN-18:15 |
EnergyTransfer:Zone:F9 S1 APARTMENT | 17.88 | 0.00 | 26-JUL-11:00 | 4229.09 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT | 12.20 | 0.00 | 02-JAN-11:45 | 4229.09 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT | 5.68 | 0.00 | 01-JAN-00:15 | 2252.28 | 19-JUL-14:00 |
EnergyTransfer:Zone:F9 S2 APARTMENT | 17.87 | 0.00 | 05-SEP-15:30 | 4227.77 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT | 12.21 | 0.00 | 02-JAN-11:45 | 4227.77 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT | 5.66 | 0.00 | 01-JAN-00:15 | 2261.07 | 19-JUL-14:00 |
EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:T SW APARTMENT | 41.15 | 0.00 | 05-SEP-08:30 | 8003.30 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 35.41 | 0.00 | 01-FEB-12:30 | 8003.30 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 5.74 | 0.00 | 01-JAN-00:15 | 3784.65 | 17-JUL-14:15 |
EnergyTransfer:Zone:T NW APARTMENT | 44.81 | 0.02 | 29-SEP-10:45 | 8127.20 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 41.05 | 0.00 | 09-FEB-15:15 | 8127.20 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 3.76 | 0.00 | 01-JAN-00:15 | 3508.77 | 18-MAY-17:45 |
EnergyTransfer:Zone:T SE APARTMENT | 40.29 | 0.03 | 21-JUN-01:45 | 7966.53 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 35.06 | 0.00 | 01-FEB-12:30 | 7966.53 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 5.23 | 0.00 | 01-JAN-00:15 | 3678.94 | 17-JUL-11:30 |
EnergyTransfer:Zone:T NE APARTMENT | 44.14 | 0.04 | 02-JUN-14:15 | 8073.71 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 40.82 | 0.00 | 10-MAR-10:45 | 8073.71 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 3.32 | 0.00 | 01-JAN-00:15 | 2930.75 | 17-JUL-10:15 |
EnergyTransfer:Zone:T N1 APARTMENT | 27.44 | 0.02 | 20-APR-11:15 | 5118.62 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 24.44 | 0.00 | 10-MAR-11:45 | 5118.62 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 3.00 | 0.00 | 01-JAN-00:15 | 2255.43 | 28-JUN-18:15 |
EnergyTransfer:Zone:T N2 APARTMENT | 27.43 | 0.03 | 12-AUG-11:00 | 5118.45 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 24.44 | 0.00 | 10-MAR-11:15 | 5118.45 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 2.99 | 0.00 | 01-JAN-00:15 | 2250.75 | 28-JUN-18:15 |
EnergyTransfer:Zone:T S1 APARTMENT | 24.25 | 0.00 | 07-AUG-05:00 | 5004.22 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 19.14 | 0.00 | 02-JAN-11:45 | 5004.22 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 5.11 | 0.00 | 01-JAN-00:15 | 2950.21 | 17-JUL-14:00 |
EnergyTransfer:Zone:T S2 APARTMENT | 24.24 | 0.00 | 11-SEP-03:45 | 5003.98 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 19.14 | 0.00 | 02-JAN-11:45 | 5003.98 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 5.10 | 0.00 | 01-JAN-00:15 | 2954.71 | 17-JUL-14:00 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Plant | 2683.12 | 558.87 | 17-AUG-01:30 | 314776.60 | 09-JAN-07:15 |
WaterSystems:EnergyTransfer | 1048.00 | 558.87 | 17-AUG-01:30 | 69917.67 | 25-FEB-07:45 |
sub cat:WaterSystems:EnergyTransfer | 1048.00 | 558.87 | 17-AUG-01:30 | 69917.67 | 25-FEB-07:45 |
EnergyTransfer:HVAC | 2670.54 | 0.00 | 13-APR-16:15 | 468537.47 | 19-DEC-03:00 |
CoolingCoils:EnergyTransfer | 464.22 | 0.00 | 01-JAN-00:15 | 294775.49 | 29-JUN-19:00 |
HeatingCoils:EnergyTransfer | 2206.31 | 0.00 | 30-MAR-16:30 | 468537.47 | 19-DEC-03:00 |
PlantLoopHeatingDemand:HVAC | 1680.29 | 0.00 | 30-MAR-16:30 | 249498.71 | 09-JAN-06:00 |
HeatingCoils:PlantLoopHeatingDemand | 1680.29 | 0.00 | 30-MAR-16:30 | 249498.71 | 09-JAN-06:00 |
Boilers:EnergyTransfer | 1635.12 | 0.00 | 10-MAR-12:45 | 248081.62 | 09-JAN-06:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 16.924 | -4.276 | 0.000 | 0.000 | 3.915 | 1.087 | 12.213 | 17.448 | 0.000 | 0.070 | 0.000 | 0.000 | -14.931 | 0.000 | -14.439 | -18.012 |
G NW APARTMENT | 21.758 | -2.634 | 0.000 | 0.000 | 3.935 | 1.087 | 12.213 | 8.166 | 0.000 | 0.070 | 0.000 | 0.000 | -16.053 | 0.000 | -14.105 | -14.436 |
OFFICE | 13.448 | -11.695 | 0.000 | 0.000 | 0.540 | 29.882 | 9.495 | 16.893 | 0.000 | 0.034 | 0.000 | 0.000 | -14.944 | 0.000 | -11.438 | -32.216 |
G NE APARTMENT | 21.654 | -2.330 | 0.000 | 0.000 | 3.942 | 1.087 | 12.213 | 7.613 | 0.000 | 0.070 | 0.000 | 0.000 | -15.797 | 0.000 | -14.142 | -14.309 |
G N1 APARTMENT | 13.343 | -2.265 | 0.000 | 0.000 | 3.946 | 1.087 | 12.213 | 2.624 | 0.000 | 0.056 | 0.000 | 0.000 | -10.173 | 0.000 | -9.421 | -11.409 |
G N2 APARTMENT | 13.343 | -2.256 | 0.000 | 0.000 | 3.947 | 1.087 | 12.213 | 2.623 | 0.000 | 0.056 | 0.000 | 0.000 | -10.171 | 0.000 | -9.422 | -11.419 |
G S1 APARTMENT | 8.561 | -4.245 | 0.000 | 0.000 | 3.917 | 1.087 | 12.213 | 12.061 | 0.000 | 0.057 | 0.000 | 0.000 | -9.108 | 0.000 | -9.808 | -14.733 |
G S2 APARTMENT | 8.310 | -4.434 | 0.000 | 0.000 | 3.913 | 1.087 | 12.213 | 12.044 | 0.000 | 0.056 | 0.000 | 0.000 | -9.122 | 0.000 | -9.850 | -14.219 |
F2 SW APARTMENT | 16.062 | -7.259 | 0.000 | 0.000 | 3.864 | 1.087 | 12.213 | 16.775 | 0.000 | 0.093 | 0.000 | 0.000 | -15.782 | 0.000 | -20.245 | -6.808 |
F2 NW APARTMENT | 21.876 | -4.378 | 0.000 | 0.000 | 3.900 | 1.087 | 12.213 | 7.750 | 0.000 | 0.092 | 0.000 | 0.000 | -16.918 | 0.000 | -19.758 | -5.864 |
F2 SE APARTMENT | 14.960 | -7.859 | 0.000 | 0.000 | 3.858 | 1.087 | 12.213 | 16.252 | 0.000 | 0.093 | 0.000 | 0.000 | -15.690 | 0.000 | -20.395 | -4.517 |
F2 NE APARTMENT | 21.685 | -4.227 | 0.000 | 0.000 | 3.913 | 1.087 | 12.213 | 7.219 | 0.000 | 0.091 | 0.000 | 0.000 | -16.617 | 0.000 | -19.727 | -5.636 |
F2 N1 APARTMENT | 11.115 | -3.885 | 0.000 | 0.000 | 3.914 | 1.087 | 12.213 | 2.418 | 0.000 | 0.070 | 0.000 | 0.000 | -10.763 | 0.000 | -13.026 | -3.143 |
F2 N2 APARTMENT | 11.115 | -3.876 | 0.000 | 0.000 | 3.915 | 1.087 | 12.213 | 2.418 | 0.000 | 0.070 | 0.000 | 0.000 | -10.759 | 0.000 | -13.021 | -3.160 |
F2 S1 APARTMENT | 6.466 | -7.167 | 0.000 | 0.000 | 3.859 | 1.087 | 12.213 | 11.634 | 0.000 | 0.073 | 0.000 | 0.000 | -9.627 | 0.000 | -13.635 | -4.903 |
F2 S2 APARTMENT | 6.415 | -7.248 | 0.000 | 0.000 | 3.857 | 1.087 | 12.213 | 11.629 | 0.000 | 0.073 | 0.000 | 0.000 | -9.632 | 0.000 | -13.651 | -4.741 |
F3 SW APARTMENT | 17.179 | -7.560 | 0.000 | 0.000 | 3.861 | 1.087 | 12.213 | 16.513 | 0.000 | 0.114 | 0.000 | 0.000 | -16.057 | 0.000 | -23.560 | -3.789 |
F3 NW APARTMENT | 23.108 | -4.664 | 0.000 | 0.000 | 3.896 | 1.087 | 12.213 | 7.604 | 0.000 | 0.112 | 0.000 | 0.000 | -17.230 | 0.000 | -23.018 | -3.108 |
F3 SE APARTMENT | 16.879 | -7.382 | 0.000 | 0.000 | 3.864 | 1.087 | 12.213 | 16.049 | 0.000 | 0.114 | 0.000 | 0.000 | -15.870 | 0.000 | -23.607 | -3.347 |
F3 NE APARTMENT | 22.924 | -4.471 | 0.000 | 0.000 | 3.908 | 1.087 | 12.213 | 7.081 | 0.000 | 0.112 | 0.000 | 0.000 | -16.917 | 0.000 | -22.986 | -2.951 |
F3 N1 APARTMENT | 11.339 | -4.261 | 0.000 | 0.000 | 3.906 | 1.087 | 12.213 | 2.352 | 0.000 | 0.086 | 0.000 | 0.000 | -10.974 | 0.000 | -15.108 | -0.639 |
F3 N2 APARTMENT | 11.338 | -4.249 | 0.000 | 0.000 | 3.907 | 1.087 | 12.213 | 2.352 | 0.000 | 0.086 | 0.000 | 0.000 | -10.971 | 0.000 | -15.103 | -0.660 |
F3 S1 APARTMENT | 6.676 | -7.775 | 0.000 | 0.000 | 3.849 | 1.087 | 12.213 | 11.458 | 0.000 | 0.091 | 0.000 | 0.000 | -9.812 | 0.000 | -15.778 | -2.008 |
F3 S2 APARTMENT | 6.671 | -7.789 | 0.000 | 0.000 | 3.848 | 1.087 | 12.213 | 11.455 | 0.000 | 0.091 | 0.000 | 0.000 | -9.812 | 0.000 | -15.784 | -1.979 |
F4 SW APARTMENT | 18.746 | -7.402 | 0.000 | 0.000 | 3.863 | 1.087 | 12.213 | 16.353 | 0.000 | 0.124 | 0.000 | 0.000 | -16.201 | 0.000 | -25.776 | -3.005 |
F4 NW APARTMENT | 24.798 | -4.626 | 0.000 | 0.000 | 3.897 | 1.087 | 12.213 | 7.522 | 0.000 | 0.122 | 0.000 | 0.000 | -17.408 | 0.000 | -25.212 | -2.392 |
F4 SE APARTMENT | 18.565 | -7.087 | 0.000 | 0.000 | 3.869 | 1.087 | 12.213 | 15.906 | 0.000 | 0.124 | 0.000 | 0.000 | -15.992 | 0.000 | -25.806 | -2.878 |
F4 NE APARTMENT | 24.619 | -4.390 | 0.000 | 0.000 | 3.908 | 1.087 | 12.213 | 7.002 | 0.000 | 0.122 | 0.000 | 0.000 | -17.089 | 0.000 | -25.195 | -2.276 |
F4 N1 APARTMENT | 12.165 | -4.309 | 0.000 | 0.000 | 3.905 | 1.087 | 12.213 | 2.317 | 0.000 | 0.093 | 0.039 | 0.000 | -11.094 | 0.000 | -16.416 | -0.000 |
F4 N2 APARTMENT | 12.165 | -4.298 | 0.000 | 0.000 | 3.906 | 1.087 | 12.213 | 2.317 | 0.000 | 0.092 | 0.020 | 0.000 | -11.091 | 0.000 | -16.411 | -0.000 |
F4 S1 APARTMENT | 7.376 | -7.745 | 0.000 | 0.000 | 3.848 | 1.087 | 12.213 | 11.351 | 0.000 | 0.098 | 0.000 | 0.000 | -9.905 | 0.000 | -17.103 | -1.219 |
F4 S2 APARTMENT | 7.373 | -7.733 | 0.000 | 0.000 | 3.848 | 1.087 | 12.213 | 11.349 | 0.000 | 0.098 | 0.000 | 0.000 | -9.904 | 0.000 | -17.106 | -1.224 |
M SW APARTMENT | 20.037 | -7.217 | 0.000 | 0.000 | 3.866 | 1.087 | 12.213 | 16.233 | 0.000 | 0.132 | 0.000 | 0.000 | -16.315 | 0.000 | -27.819 | -2.216 |
M NW APARTMENT | 26.134 | -4.574 | 0.000 | 0.000 | 3.900 | 1.087 | 12.213 | 7.463 | 0.000 | 0.130 | 0.000 | 0.000 | -17.549 | 0.000 | -27.221 | -1.582 |
M SE APARTMENT | 19.869 | -6.881 | 0.000 | 0.000 | 3.872 | 1.087 | 12.213 | 15.793 | 0.000 | 0.131 | 0.000 | 0.000 | -16.096 | 0.000 | -27.844 | -2.143 |
M NE APARTMENT | 25.949 | -4.323 | 0.000 | 0.000 | 3.909 | 1.087 | 12.213 | 6.944 | 0.000 | 0.130 | 0.000 | 0.000 | -17.226 | 0.000 | -27.211 | -1.471 |
M N1 APARTMENT | 12.807 | -4.325 | 0.000 | 0.000 | 3.906 | 1.087 | 12.213 | 2.293 | 0.000 | 0.098 | 0.796 | 0.000 | -11.189 | 0.000 | -17.685 | -0.000 |
M N2 APARTMENT | 12.801 | -4.313 | 0.000 | 0.000 | 3.906 | 1.087 | 12.213 | 2.293 | 0.000 | 0.098 | 0.782 | 0.000 | -11.186 | 0.000 | -17.681 | -0.000 |
M S1 APARTMENT | 7.955 | -7.637 | 0.000 | 0.000 | 3.850 | 1.087 | 12.213 | 11.271 | 0.000 | 0.104 | 0.001 | 0.000 | -9.976 | 0.000 | -18.404 | -0.461 |
M S2 APARTMENT | 7.956 | -7.620 | 0.000 | 0.000 | 3.850 | 1.087 | 12.213 | 11.270 | 0.000 | 0.104 | 0.001 | 0.000 | -9.974 | 0.000 | -18.407 | -0.478 |
F6 SW APARTMENT | 21.884 | -6.567 | 0.000 | 0.000 | 3.874 | 1.087 | 12.213 | 16.168 | 0.000 | 0.138 | 0.000 | 0.000 | -16.350 | 0.000 | -29.510 | -2.936 |
F6 NW APARTMENT | 28.150 | -4.164 | 0.000 | 0.000 | 3.908 | 1.087 | 12.213 | 7.444 | 0.000 | 0.136 | 0.000 | 0.000 | -17.606 | 0.000 | -28.869 | -2.299 |
F6 SE APARTMENT | 21.710 | -6.245 | 0.000 | 0.000 | 3.881 | 1.087 | 12.213 | 15.733 | 0.000 | 0.137 | 0.000 | 0.000 | -16.126 | 0.000 | -29.531 | -2.860 |
F6 NE APARTMENT | 27.984 | -3.871 | 0.000 | 0.000 | 3.916 | 1.087 | 12.213 | 6.925 | 0.000 | 0.137 | 0.000 | 0.000 | -17.281 | 0.000 | -28.878 | -2.231 |
F6 N1 APARTMENT | 14.103 | -3.899 | 0.000 | 0.000 | 3.913 | 1.087 | 12.213 | 2.291 | 0.000 | 0.104 | 0.115 | 0.000 | -11.225 | 0.000 | -18.702 | -0.000 |
F6 N2 APARTMENT | 14.100 | -3.881 | 0.000 | 0.000 | 3.914 | 1.087 | 12.213 | 2.291 | 0.000 | 0.104 | 0.096 | 0.000 | -11.223 | 0.000 | -18.701 | -0.000 |
F6 S1 APARTMENT | 8.971 | -6.936 | 0.000 | 0.000 | 3.860 | 1.087 | 12.213 | 11.228 | 0.000 | 0.108 | 0.000 | 0.000 | -9.993 | 0.000 | -19.449 | -1.087 |
F6 S2 APARTMENT | 8.972 | -6.918 | 0.000 | 0.000 | 3.860 | 1.087 | 12.213 | 11.226 | 0.000 | 0.108 | 0.000 | 0.000 | -9.991 | 0.000 | -19.451 | -1.105 |
F7 SW APARTMENT | 23.394 | -6.133 | 0.000 | 0.000 | 3.881 | 1.087 | 12.213 | 16.107 | 0.000 | 0.143 | 0.000 | 0.000 | -16.392 | 0.000 | -31.002 | -3.298 |
F7 NW APARTMENT | 29.746 | -3.898 | 0.000 | 0.000 | 3.914 | 1.087 | 12.213 | 7.423 | 0.000 | 0.141 | 0.000 | 0.000 | -17.667 | 0.000 | -30.331 | -2.627 |
F7 SE APARTMENT | 23.213 | -5.824 | 0.000 | 0.000 | 3.888 | 1.087 | 12.213 | 15.676 | 0.000 | 0.143 | 0.000 | 0.000 | -16.163 | 0.000 | -31.019 | -3.214 |
F7 NE APARTMENT | 29.595 | -3.585 | 0.000 | 0.000 | 3.921 | 1.087 | 12.213 | 6.904 | 0.000 | 0.143 | 0.000 | 0.000 | -17.341 | 0.000 | -30.354 | -2.581 |
F7 N1 APARTMENT | 15.099 | -3.627 | 0.000 | 0.000 | 3.919 | 1.087 | 12.213 | 2.287 | 0.000 | 0.109 | 0.000 | 0.000 | -11.264 | 0.000 | -19.603 | -0.219 |
F7 N2 APARTMENT | 15.101 | -3.618 | 0.000 | 0.000 | 3.919 | 1.087 | 12.213 | 2.286 | 0.000 | 0.109 | 0.000 | 0.000 | -11.262 | 0.000 | -19.602 | -0.233 |
F7 S1 APARTMENT | 9.802 | -6.465 | 0.000 | 0.000 | 3.867 | 1.087 | 12.213 | 11.188 | 0.000 | 0.112 | 0.000 | 0.000 | -10.015 | 0.000 | -20.369 | -1.420 |
F7 S2 APARTMENT | 9.803 | -6.446 | 0.000 | 0.000 | 3.868 | 1.087 | 12.213 | 11.186 | 0.000 | 0.112 | 0.000 | 0.000 | -10.012 | 0.000 | -20.371 | -1.439 |
F8 SW APARTMENT | 24.834 | -5.788 | 0.000 | 0.000 | 3.886 | 1.087 | 12.213 | 16.054 | 0.000 | 0.148 | 0.000 | 0.000 | -16.429 | 0.000 | -32.372 | -3.633 |
F8 NW APARTMENT | 31.280 | -3.678 | 0.000 | 0.000 | 3.918 | 1.087 | 12.213 | 7.402 | 0.000 | 0.147 | 0.000 | 0.000 | -17.725 | 0.000 | -31.690 | -2.954 |
F8 SE APARTMENT | 24.654 | -5.483 | 0.000 | 0.000 | 3.894 | 1.087 | 12.213 | 15.626 | 0.000 | 0.148 | 0.000 | 0.000 | -16.198 | 0.000 | -32.392 | -3.549 |
F8 NE APARTMENT | 31.122 | -3.382 | 0.000 | 0.000 | 3.925 | 1.087 | 12.213 | 6.885 | 0.000 | 0.148 | 0.000 | 0.000 | -17.395 | 0.000 | -31.712 | -2.890 |
F8 N1 APARTMENT | 16.074 | -3.430 | 0.000 | 0.000 | 3.923 | 1.087 | 12.213 | 2.282 | 0.000 | 0.114 | 0.000 | 0.000 | -11.299 | 0.000 | -20.443 | -0.519 |
F8 N2 APARTMENT | 16.073 | -3.421 | 0.000 | 0.000 | 3.924 | 1.087 | 12.213 | 2.282 | 0.000 | 0.114 | 0.000 | 0.000 | -11.297 | 0.000 | -20.442 | -0.530 |
F8 S1 APARTMENT | 10.634 | -6.084 | 0.000 | 0.000 | 3.874 | 1.087 | 12.213 | 11.153 | 0.000 | 0.116 | 0.000 | 0.000 | -10.033 | 0.000 | -21.223 | -1.737 |
F8 S2 APARTMENT | 10.634 | -6.066 | 0.000 | 0.000 | 3.874 | 1.087 | 12.213 | 11.152 | 0.000 | 0.116 | 0.000 | 0.000 | -10.031 | 0.000 | -21.225 | -1.754 |
F9 SW APARTMENT | 27.170 | -5.507 | 0.000 | 0.000 | 3.892 | 1.087 | 12.213 | 16.025 | 0.000 | 0.154 | 0.000 | 0.000 | -16.431 | 0.000 | -33.605 | -4.996 |
F9 NW APARTMENT | 33.765 | -3.536 | 0.000 | 0.000 | 3.921 | 1.087 | 12.213 | 7.392 | 0.000 | 0.152 | 0.000 | 0.000 | -17.746 | 0.000 | -32.925 | -4.322 |
F9 SE APARTMENT | 27.002 | -5.158 | 0.000 | 0.000 | 3.898 | 1.087 | 12.213 | 15.598 | 0.000 | 0.154 | 0.000 | 0.000 | -16.201 | 0.000 | -33.644 | -4.948 |
F9 NE APARTMENT | 33.592 | -3.237 | 0.000 | 0.000 | 3.927 | 1.087 | 12.213 | 6.875 | 0.000 | 0.153 | 0.000 | 0.000 | -17.413 | 0.000 | -32.955 | -4.242 |
F9 N1 APARTMENT | 17.925 | -3.255 | 0.000 | 0.000 | 3.926 | 1.087 | 12.213 | 2.282 | 0.000 | 0.119 | 0.000 | 0.000 | -11.310 | 0.000 | -21.211 | -1.775 |
F9 N2 APARTMENT | 17.924 | -3.245 | 0.000 | 0.000 | 3.927 | 1.087 | 12.213 | 2.281 | 0.000 | 0.119 | 0.000 | 0.000 | -11.308 | 0.000 | -21.211 | -1.784 |
F9 S1 APARTMENT | 12.205 | -5.679 | 0.000 | 0.000 | 3.880 | 1.087 | 12.213 | 11.134 | 0.000 | 0.120 | 0.000 | 0.000 | -10.029 | 0.000 | -21.987 | -2.945 |
F9 S2 APARTMENT | 12.206 | -5.662 | 0.000 | 0.000 | 3.881 | 1.087 | 12.213 | 11.133 | 0.000 | 0.121 | 0.000 | 0.000 | -10.026 | 0.000 | -21.989 | -2.961 |
T SW APARTMENT | 35.413 | -5.740 | 0.000 | 0.000 | 3.916 | 1.087 | 12.213 | 15.844 | 0.000 | 0.157 | 0.000 | 0.000 | -15.949 | 0.000 | -34.675 | -12.265 |
T NW APARTMENT | 41.045 | -3.762 | 0.000 | 0.000 | 3.938 | 1.087 | 12.213 | 7.273 | 0.000 | 0.155 | 0.000 | 0.000 | -17.316 | 0.000 | -34.025 | -10.607 |
T SE APARTMENT | 35.058 | -5.234 | 0.000 | 0.000 | 3.924 | 1.087 | 12.213 | 15.444 | 0.000 | 0.157 | 0.000 | 0.000 | -15.741 | 0.000 | -34.723 | -12.184 |
T NE APARTMENT | 40.817 | -3.324 | 0.000 | 0.000 | 3.944 | 1.087 | 12.213 | 6.777 | 0.000 | 0.156 | 0.000 | 0.000 | -17.007 | 0.000 | -34.088 | -10.573 |
T N1 APARTMENT | 24.441 | -3.003 | 0.000 | 0.000 | 3.940 | 1.087 | 12.213 | 2.250 | 0.000 | 0.123 | 0.000 | 0.000 | -11.031 | 0.000 | -21.918 | -8.102 |
T N2 APARTMENT | 24.437 | -2.989 | 0.000 | 0.000 | 3.941 | 1.087 | 12.213 | 2.248 | 0.000 | 0.123 | 0.000 | 0.000 | -11.027 | 0.000 | -21.923 | -8.108 |
T S1 APARTMENT | 19.138 | -5.112 | 0.000 | 0.000 | 3.904 | 1.087 | 12.213 | 11.040 | 0.000 | 0.124 | 0.000 | 0.000 | -9.772 | 0.000 | -22.663 | -9.959 |
T S2 APARTMENT | 19.141 | -5.102 | 0.000 | 0.000 | 3.904 | 1.087 | 12.213 | 11.036 | 0.000 | 0.124 | 0.000 | 0.000 | -9.768 | 0.000 | -22.668 | -9.968 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 3.684 | 0.000 | 0.180 | 73.886 | 0.000 | -3.250 | 0.000 | -90.940 | -0.000 |
F2 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 1.631 | 0.000 | 0.003 | 0.000 | 0.000 | -2.015 | 0.000 | -2.843 | -13.215 |
F3 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 1.588 | 0.000 | 0.003 | 0.000 | 0.000 | -2.101 | 0.000 | -3.445 | -12.484 |
F4 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 1.566 | 0.000 | 0.003 | 0.000 | 0.000 | -2.136 | 0.000 | -3.874 | -11.998 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32.880 | 0.000 | 1.542 | 0.000 | 0.003 | 0.000 | 0.000 | -2.180 | 0.000 | -4.321 | -27.924 |
F6 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 1.550 | 0.000 | 0.004 | 0.000 | 0.000 | -2.156 | 0.000 | -4.484 | -11.354 |
F7 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 1.549 | 0.000 | 0.004 | 0.000 | 0.000 | -2.151 | 0.000 | -4.707 | -11.136 |
F8 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 1.546 | 0.000 | 0.004 | 0.000 | 0.000 | -2.151 | 0.000 | -4.918 | -10.921 |
F9 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 1.545 | 0.000 | 0.004 | 0.000 | 0.000 | -2.146 | 0.000 | -5.098 | -10.745 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 8.151 | 1.511 | 0.000 | 0.002 | 0.000 | 0.000 | -2.098 | 0.000 | -5.338 | -18.668 |
Total Facility | 1490.671 | -411.616 | 0.000 | 0.000 | 308.459 | 296.560 | 982.450 | 759.650 | 0.000 | 9.184 | 75.738 | 0.000 | -1102.703 | 0.000 | -1915.737 | -492.654 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 25-AUG-16:15 | 0.00 | -2269.25 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 2807.36 | 0.00 | 165.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1441.75 |
G NW APARTMENT | 06-JUL-17:45 | 0.00 | -2035.98 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 2808.28 | 0.00 | 137.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1728.26 |
OFFICE | 17-JUL-13:45 | 0.00 | -3427.17 | 0.00 | 0.00 | 65.20 | 2345.88 | 588.62 | 2329.71 | 0.00 | 90.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1992.96 |
G NE APARTMENT | 26-JUN-09:30 | 0.00 | -1667.10 | 0.00 | 0.00 | 40.76 | 12.97 | 406.15 | 2388.08 | 0.00 | 288.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1469.37 |
G N1 APARTMENT | 29-JUN-18:30 | 0.00 | -1214.43 | 0.00 | 0.00 | 141.82 | 103.77 | 547.42 | 752.35 | 0.00 | 295.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -626.88 |
G N2 APARTMENT | 29-JUN-18:30 | 0.00 | -1202.76 | 0.00 | 0.00 | 141.82 | 103.77 | 547.42 | 752.64 | 0.00 | 295.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -638.83 |
G S1 APARTMENT | 11-AUG-12:45 | 0.00 | -1582.29 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2553.86 | 0.00 | 225.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1639.03 |
G S2 APARTMENT | 11-AUG-12:45 | 0.00 | -1583.81 | 0.00 | 0.00 | 40.59 | 12.97 | 388.49 | 2552.02 | 0.00 | 215.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1625.27 |
F2 SW APARTMENT | 25-AUG-16:15 | 0.00 | -2964.18 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 2772.53 | 0.00 | 192.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -738.68 |
F2 NW APARTMENT | 19-JUL-17:30 | 0.00 | -2647.95 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 2607.88 | 0.00 | 198.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -976.72 |
F2 SE APARTMENT | 17-JUL-12:00 | 0.00 | -2905.83 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 2620.77 | 0.00 | 195.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -370.39 |
F2 NE APARTMENT | 17-JUL-10:15 | 0.00 | -2215.58 | 0.00 | 0.00 | 40.56 | 12.97 | 412.03 | 2164.22 | 0.00 | 13.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -427.40 |
F2 N1 APARTMENT | 19-JUL-17:30 | 0.00 | -1406.07 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 402.72 | 0.00 | 186.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1.38 |
F2 N2 APARTMENT | 19-JUL-17:15 | 0.00 | -1395.51 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 355.27 | 0.00 | 219.51 | 2.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 S1 APARTMENT | 11-AUG-12:45 | 0.00 | -2044.91 | 0.00 | 0.00 | 40.65 | 12.97 | 388.49 | 2526.17 | 0.00 | 255.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1179.07 |
F2 S2 APARTMENT | 11-AUG-12:45 | 0.00 | -2071.39 | 0.00 | 0.00 | 40.67 | 12.97 | 388.49 | 2525.87 | 0.00 | 256.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1153.06 |
F3 SW APARTMENT | 18-MAY-18:00 | 0.00 | -3108.34 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 2219.77 | 0.00 | 396.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -325.59 |
F3 NW APARTMENT | 18-MAY-18:00 | 0.00 | -2813.94 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 2539.54 | 0.00 | 396.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -939.78 |
F3 SE APARTMENT | 17-JUL-12:00 | 0.00 | -2853.69 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 2604.32 | 0.00 | 230.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -440.91 |
F3 NE APARTMENT | 17-JUL-09:45 | 0.00 | -2296.60 | 0.00 | 0.00 | 40.60 | 12.97 | 406.15 | 2444.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -607.72 |
F3 N1 APARTMENT | 19-JUL-17:15 | 0.00 | -1475.36 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 352.71 | 0.00 | 235.48 | 69.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 N2 APARTMENT | 19-JUL-17:15 | 0.00 | -1464.70 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 352.89 | 0.00 | 235.48 | 58.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 S1 APARTMENT | 19-JUL-14:00 | 0.00 | -2114.42 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1610.50 | 0.00 | 426.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -359.26 |
F3 S2 APARTMENT | 19-JUL-14:00 | 0.00 | -2122.89 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1610.33 | 0.00 | 426.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -350.63 |
F4 SW APARTMENT | 18-MAY-18:00 | 0.00 | -3161.64 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 2210.25 | 0.00 | 426.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -293.20 |
F4 NW APARTMENT | 18-MAY-18:00 | 0.00 | -2876.37 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 2527.00 | 0.00 | 426.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -895.22 |
F4 SE APARTMENT | 17-JUL-11:45 | 0.00 | -2874.32 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 2662.30 | 0.00 | 211.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -459.35 |
F4 NE APARTMENT | 17-JUL-09:15 | 0.00 | -2297.19 | 0.00 | 0.00 | 40.76 | 12.97 | 406.15 | 2659.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -822.37 |
F4 N1 APARTMENT | 18-MAY-18:00 | 0.00 | -1513.13 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 473.82 | 0.00 | 398.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -176.87 |
F4 N2 APARTMENT | 18-MAY-18:00 | 0.00 | -1492.95 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 474.25 | 0.00 | 398.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -197.49 |
F4 S1 APARTMENT | 19-JUL-14:00 | 0.00 | -2155.44 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1598.83 | 0.00 | 462.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -341.87 |
F4 S2 APARTMENT | 19-JUL-14:00 | 0.00 | -2163.00 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1598.67 | 0.00 | 462.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -334.14 |
M SW APARTMENT | 18-MAY-18:00 | 0.00 | -3205.20 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 2202.51 | 0.00 | 451.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -266.34 |
M NW APARTMENT | 18-MAY-18:00 | 0.00 | -2921.08 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 2517.20 | 0.00 | 451.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -865.16 |
M SE APARTMENT | 17-JUL-11:45 | 0.00 | -2916.31 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 2651.74 | 0.00 | 229.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -424.46 |
M NE APARTMENT | 17-JUL-09:15 | 0.00 | -2314.49 | 0.00 | 0.00 | 40.76 | 12.97 | 406.15 | 2658.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -804.10 |
M N1 APARTMENT | 18-MAY-18:00 | 0.00 | -1563.96 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 471.70 | 0.00 | 420.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -146.19 |
M N2 APARTMENT | 18-MAY-18:00 | 0.00 | -1544.15 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 472.12 | 0.00 | 420.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -166.42 |
M S1 APARTMENT | 19-JUL-14:00 | 0.00 | -2204.96 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1589.62 | 0.00 | 490.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -311.44 |
M S2 APARTMENT | 19-JUL-14:00 | 0.00 | -2212.40 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1589.47 | 0.00 | 490.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -303.84 |
F6 SW APARTMENT | 18-MAY-18:00 | 0.00 | -3179.34 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 2197.76 | 0.00 | 471.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -307.82 |
F6 NW APARTMENT | 18-MAY-18:00 | 0.00 | -2888.13 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 2510.95 | 0.00 | 471.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -912.23 |
F6 SE APARTMENT | 17-JUL-11:45 | 0.00 | -2896.02 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 2644.40 | 0.00 | 244.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -452.46 |
F6 NE APARTMENT | 17-JUL-07:45 | 0.00 | -2338.74 | 0.00 | 0.00 | 63.58 | 19.46 | 388.49 | 2687.29 | 0.00 | 282.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1102.51 |
F6 N1 APARTMENT | 18-MAY-18:00 | 0.00 | -1537.61 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 471.42 | 0.00 | 439.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -190.80 |
F6 N2 APARTMENT | 18-MAY-18:00 | 0.00 | -1518.55 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 471.83 | 0.00 | 439.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -210.26 |
F6 S1 APARTMENT | 19-JUL-14:00 | 0.00 | -2190.84 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1583.13 | 0.00 | 514.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -342.62 |
F6 S2 APARTMENT | 19-JUL-14:00 | 0.00 | -2198.32 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1582.97 | 0.00 | 514.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -334.98 |
F7 SW APARTMENT | 18-MAY-18:00 | 0.00 | -3170.14 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 2193.18 | 0.00 | 488.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -329.79 |
F7 NW APARTMENT | 18-MAY-18:00 | 0.00 | -2873.74 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 2505.14 | 0.00 | 488.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -938.16 |
F7 SE APARTMENT | 17-JUL-11:45 | 0.00 | -2894.78 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 2637.58 | 0.00 | 257.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -460.03 |
F7 NE APARTMENT | 17-JUL-19:00 | 0.00 | -2343.61 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 382.62 | 0.00 | 619.83 | 548.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 N1 APARTMENT | 26-MAY-15:45 | 0.00 | -1557.40 | 0.00 | 0.00 | 48.90 | 45.40 | 470.89 | 599.94 | 0.00 | 600.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -208.56 |
F7 N2 APARTMENT | 26-MAY-15:45 | 0.00 | -1556.55 | 0.00 | 0.00 | 48.90 | 45.40 | 470.89 | 600.27 | 0.00 | 603.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -212.17 |
F7 S1 APARTMENT | 19-JUL-14:00 | 0.00 | -2194.45 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1577.30 | 0.00 | 534.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -353.23 |
F7 S2 APARTMENT | 19-JUL-14:00 | 0.00 | -2201.99 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1577.14 | 0.00 | 534.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -345.54 |
F8 SW APARTMENT | 18-MAY-18:00 | 0.00 | -3168.31 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 2188.91 | 0.00 | 503.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -342.36 |
F8 NW APARTMENT | 18-MAY-18:00 | 0.00 | -2872.28 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 2499.64 | 0.00 | 503.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -949.12 |
F8 SE APARTMENT | 17-JUL-12:00 | 0.00 | -2924.90 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 2560.71 | 0.00 | 326.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -422.43 |
F8 NE APARTMENT | 17-JUL-19:00 | 0.00 | -2365.60 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 381.61 | 0.00 | 640.77 | 550.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 N1 APARTMENT | 28-JUN-18:15 | 0.00 | -1622.40 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 651.31 | 0.00 | 557.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -379.06 |
F8 N2 APARTMENT | 28-JUN-18:15 | 0.00 | -1622.61 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 651.54 | 0.00 | 559.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -381.09 |
F8 S1 APARTMENT | 19-JUL-14:00 | 0.00 | -2205.25 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1572.06 | 0.00 | 551.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -354.55 |
F8 S2 APARTMENT | 19-JUL-14:00 | 0.00 | -2212.86 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1571.90 | 0.00 | 551.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -346.78 |
F9 SW APARTMENT | 18-MAY-17:45 | 0.00 | -3310.36 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 2369.24 | 0.00 | 536.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -413.17 |
F9 NW APARTMENT | 18-MAY-17:45 | 0.00 | -2972.35 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 2584.69 | 0.00 | 536.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -966.63 |
F9 SE APARTMENT | 17-JUL-12:00 | 0.00 | -3006.89 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 2553.56 | 0.00 | 340.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -346.78 |
F9 NE APARTMENT | 17-JUL-18:45 | 0.00 | -2474.46 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 405.84 | 0.00 | 648.86 | 626.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 N1 APARTMENT | 28-JUN-18:15 | 0.00 | -1745.72 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 648.88 | 0.00 | 585.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -281.18 |
F9 N2 APARTMENT | 28-JUN-18:15 | 0.00 | -1745.91 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 649.10 | 0.00 | 587.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -283.28 |
F9 S1 APARTMENT | 19-JUL-14:00 | 0.00 | -2252.40 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1566.64 | 0.00 | 566.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -317.14 |
F9 S2 APARTMENT | 19-JUL-14:00 | 0.00 | -2261.19 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1566.46 | 0.00 | 566.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -308.17 |
T SW APARTMENT | 17-JUL-14:15 | 0.00 | -3784.10 | 0.00 | 0.00 | 40.75 | 22.70 | 400.26 | 2958.84 | 0.00 | 312.93 | 48.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 18-MAY-17:45 | 0.00 | -3507.96 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 2546.10 | 0.00 | 548.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -404.41 |
T SE APARTMENT | 17-JUL-11:30 | 0.00 | -3679.46 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 2677.92 | 0.00 | 226.67 | 315.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 17-JUL-10:15 | 0.00 | -2930.20 | 0.00 | 0.00 | 40.75 | 12.97 | 412.03 | 2124.97 | 0.00 | 23.80 | 315.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 28-JUN-18:15 | 0.00 | -2258.06 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 638.84 | 0.00 | 641.27 | 184.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 28-JUN-18:15 | 0.00 | -2253.34 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 639.51 | 0.00 | 645.77 | 175.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 17-JUL-14:00 | 0.00 | -2949.51 | 0.00 | 0.00 | 40.54 | 12.97 | 382.60 | 1652.46 | 0.00 | 191.79 | 669.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S2 APARTMENT | 17-JUL-14:00 | 0.00 | -2954.02 | 0.00 | 0.00 | 40.54 | 12.97 | 382.60 | 1652.32 | 0.00 | 191.80 | 673.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 17-JUL-14:15 | 0.00 | -168898.75 | 0.00 | 0.00 | 3284.64 | 9873.49 | 32370.09 | 129684.23 | 0.00 | 16821.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -23135.34 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 11-JAN-12:00 | 3770.99 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1037.87 | 0.00 | -2345.39 | -860.15 |
G NW APARTMENT | 11-JAN-12:00 | 3888.48 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1190.66 | 0.00 | -2345.39 | -824.85 |
OFFICE | 19-DEC-03:00 | 3528.72 | 0.00 | 0.00 | 0.00 | 0.00 | 469.18 | 194.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1711.26 | 0.00 | -2083.70 | -397.18 |
G NE APARTMENT | 11-JAN-12:00 | 3851.26 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1168.37 | 0.00 | -2345.39 | -809.92 |
G N1 APARTMENT | 08-JAN-08:30 | 2549.67 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1013.75 | 0.00 | -939.23 | -1078.61 |
G N2 APARTMENT | 08-JAN-08:30 | 2547.21 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1013.78 | 0.00 | -939.23 | -1076.12 |
G S1 APARTMENT | 11-JAN-12:00 | 2319.32 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -573.78 | 0.00 | -1414.68 | -803.28 |
G S2 APARTMENT | 11-JAN-12:00 | 2278.28 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -574.73 | 0.00 | -1414.68 | -761.29 |
F2 SW APARTMENT | 19-DEC-03:00 | 4550.13 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1778.69 | 0.00 | -2995.77 | -201.39 |
F2 NW APARTMENT | 19-DEC-03:00 | 4729.68 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1799.12 | 0.00 | -2995.77 | -360.51 |
F2 SE APARTMENT | 19-DEC-03:00 | 4474.72 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1762.58 | 0.00 | -2995.77 | -142.09 |
F2 NE APARTMENT | 19-DEC-03:00 | 4727.69 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1780.67 | 0.00 | -2995.78 | -376.95 |
F2 N1 APARTMENT | 19-DEC-03:00 | 2785.67 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1098.29 | 0.00 | -1806.98 | -306.11 |
F2 N2 APARTMENT | 19-DEC-03:00 | 2786.01 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1098.28 | 0.00 | -1806.99 | -306.46 |
F2 S1 APARTMENT | 19-DEC-03:00 | 2591.60 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1073.91 | 0.00 | -1806.97 | -136.43 |
F2 S2 APARTMENT | 19-DEC-03:00 | 2586.62 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1074.02 | 0.00 | -1806.97 | -131.34 |
F3 SW APARTMENT | 11-JAN-12:00 | 5066.56 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1162.15 | 0.00 | -3993.42 | -383.41 |
F3 NW APARTMENT | 11-JAN-12:00 | 5194.03 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1308.38 | 0.00 | -3993.43 | -364.64 |
F3 SE APARTMENT | 11-JAN-12:00 | 5014.90 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1129.25 | 0.00 | -3993.43 | -364.65 |
F3 NE APARTMENT | 19-DEC-03:00 | 5181.38 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1807.85 | 0.00 | -3547.68 | -251.56 |
F3 N1 APARTMENT | 19-DEC-03:00 | 3017.12 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1117.25 | 0.00 | -2139.88 | -185.71 |
F3 N2 APARTMENT | 19-DEC-03:00 | 3017.37 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1117.24 | 0.00 | -2139.88 | -185.96 |
F3 S1 APARTMENT | 11-JAN-12:00 | 2862.98 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -651.65 | 0.00 | -2408.73 | -275.03 |
F3 S2 APARTMENT | 11-JAN-12:00 | 2860.97 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -651.70 | 0.00 | -2408.73 | -272.96 |
F4 SW APARTMENT | 11-JAN-12:00 | 5534.61 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1182.81 | 0.00 | -4464.80 | -359.43 |
F4 NW APARTMENT | 11-JAN-12:00 | 5661.41 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1327.94 | 0.00 | -4464.81 | -341.09 |
F4 SE APARTMENT | 11-JAN-12:00 | 5488.45 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1147.84 | 0.00 | -4464.81 | -348.22 |
F4 NE APARTMENT | 11-JAN-12:00 | 5613.80 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1293.13 | 0.00 | -4464.82 | -328.26 |
F4 N1 APARTMENT | 11-JAN-12:00 | 3265.12 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -813.89 | 0.00 | -2693.09 | -230.56 |
F4 N2 APARTMENT | 11-JAN-12:00 | 3263.84 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -813.92 | 0.00 | -2693.10 | -229.25 |
F4 S1 APARTMENT | 11-JAN-12:00 | 3135.47 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -664.85 | 0.00 | -2693.06 | -249.98 |
F4 S2 APARTMENT | 11-JAN-12:00 | 3134.08 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -664.88 | 0.00 | -2693.06 | -248.56 |
M SW APARTMENT | 11-JAN-12:00 | 5912.61 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1198.36 | 0.00 | -4853.51 | -333.17 |
M NW APARTMENT | 11-JAN-12:00 | 6037.06 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1342.68 | 0.00 | -4853.52 | -313.27 |
M SE APARTMENT | 11-JAN-12:00 | 5866.54 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1162.12 | 0.00 | -4853.51 | -323.32 |
M NE APARTMENT | 11-JAN-12:00 | 5988.81 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1306.65 | 0.00 | -4853.53 | -301.06 |
M N1 APARTMENT | 11-JAN-12:00 | 3482.46 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -823.02 | 0.00 | -2927.55 | -204.30 |
M N2 APARTMENT | 11-JAN-12:00 | 3481.18 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -823.06 | 0.00 | -2927.55 | -202.99 |
M S1 APARTMENT | 11-JAN-12:00 | 3355.19 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -674.75 | 0.00 | -2927.51 | -225.35 |
M S2 APARTMENT | 11-JAN-12:00 | 3353.90 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -674.78 | 0.00 | -2927.51 | -224.03 |
F6 SW APARTMENT | 11-JAN-12:00 | 6289.61 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1208.74 | 0.00 | -5188.61 | -364.69 |
F6 NW APARTMENT | 11-JAN-12:00 | 6413.85 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1352.54 | 0.00 | -5188.62 | -345.11 |
F6 SE APARTMENT | 11-JAN-12:00 | 6243.01 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1171.64 | 0.00 | -5188.61 | -355.17 |
F6 NE APARTMENT | 11-JAN-12:00 | 6364.93 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1315.64 | 0.00 | -5188.62 | -333.10 |
F6 N1 APARTMENT | 11-JAN-12:00 | 3720.93 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -829.01 | 0.00 | -3129.67 | -234.66 |
F6 N2 APARTMENT | 11-JAN-12:00 | 3719.63 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -829.04 | 0.00 | -3129.67 | -233.34 |
F6 S1 APARTMENT | 11-JAN-12:00 | 3593.75 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -681.26 | 0.00 | -3129.64 | -255.27 |
F6 S2 APARTMENT | 11-JAN-12:00 | 3592.47 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -681.29 | 0.00 | -3129.64 | -253.96 |
F7 SW APARTMENT | 11-JAN-12:00 | 6609.71 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1217.75 | 0.00 | -5485.64 | -378.75 |
F7 NW APARTMENT | 11-JAN-12:00 | 6732.44 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1361.13 | 0.00 | -5485.65 | -358.09 |
F7 SE APARTMENT | 11-JAN-12:00 | 6562.72 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1180.00 | 0.00 | -5485.64 | -369.50 |
F7 NE APARTMENT | 11-JAN-12:00 | 6683.03 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1323.57 | 0.00 | -5485.64 | -346.23 |
F7 N1 APARTMENT | 11-JAN-12:00 | 3918.45 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -834.23 | 0.00 | -3308.83 | -247.80 |
F7 N2 APARTMENT | 11-JAN-12:00 | 3917.15 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -834.27 | 0.00 | -3308.83 | -246.48 |
F7 S1 APARTMENT | 11-JAN-12:00 | 3793.22 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -686.90 | 0.00 | -3308.80 | -269.93 |
F7 S2 APARTMENT | 11-JAN-12:00 | 3791.94 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -686.93 | 0.00 | -3308.80 | -268.63 |
F8 SW APARTMENT | 11-JAN-12:00 | 6904.01 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1225.25 | 0.00 | -5754.00 | -397.17 |
F8 NW APARTMENT | 11-JAN-12:00 | 7024.49 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1368.28 | 0.00 | -5754.01 | -374.62 |
F8 SE APARTMENT | 11-JAN-12:00 | 6856.71 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1186.97 | 0.00 | -5754.01 | -388.15 |
F8 NE APARTMENT | 11-JAN-12:00 | 6974.76 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1330.21 | 0.00 | -5754.01 | -362.96 |
F8 N1 APARTMENT | 11-JAN-12:00 | 4101.53 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -838.56 | 0.00 | -3470.70 | -264.68 |
F8 N2 APARTMENT | 11-JAN-12:00 | 4100.24 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -838.60 | 0.00 | -3470.70 | -263.36 |
F8 S1 APARTMENT | 11-JAN-12:00 | 3979.48 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -691.55 | 0.00 | -3470.68 | -289.68 |
F8 S2 APARTMENT | 11-JAN-12:00 | 3978.22 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -691.58 | 0.00 | -3470.68 | -288.38 |
F9 SW APARTMENT | 11-JAN-12:00 | 7259.21 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1228.98 | 0.00 | -5999.89 | -502.77 |
F9 NW APARTMENT | 11-JAN-12:00 | 7376.75 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1371.72 | 0.00 | -5999.89 | -477.56 |
F9 SE APARTMENT | 11-JAN-12:00 | 7209.88 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1190.35 | 0.00 | -5999.89 | -492.07 |
F9 NE APARTMENT | 11-JAN-12:00 | 7324.91 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1333.31 | 0.00 | -5999.89 | -464.13 |
F9 N1 APARTMENT | 11-JAN-12:00 | 4346.46 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -840.52 | 0.00 | -3619.01 | -359.36 |
F9 N2 APARTMENT | 11-JAN-12:00 | 4345.10 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -840.55 | 0.00 | -3619.01 | -357.96 |
F9 S1 APARTMENT | 11-JAN-12:00 | 4228.55 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -693.77 | 0.00 | -3618.99 | -388.21 |
F9 S2 APARTMENT | 11-JAN-12:00 | 4227.23 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -693.80 | 0.00 | -3618.99 | -386.86 |
T SW APARTMENT | 11-JAN-12:00 | 8002.60 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1204.86 | 0.00 | -6227.07 | -1043.09 |
T NW APARTMENT | 11-JAN-12:00 | 8126.49 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1346.29 | 0.00 | -6227.08 | -1025.54 |
T SE APARTMENT | 19-DEC-03:00 | 7966.09 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1793.75 | 0.00 | -5530.94 | -1067.11 |
T NE APARTMENT | 11-JAN-12:00 | 8073.00 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1308.22 | 0.00 | -6227.08 | -1010.13 |
T N1 APARTMENT | 19-DEC-03:00 | 5118.17 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1132.25 | 0.00 | -3336.25 | -1075.38 |
T N2 APARTMENT | 19-DEC-03:00 | 5118.01 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1132.26 | 0.00 | -3336.25 | -1075.21 |
T S1 APARTMENT | 19-DEC-03:00 | 5003.77 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1096.11 | 0.00 | -3336.25 | -997.13 |
T S2 APARTMENT | 19-DEC-03:00 | 5003.53 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1096.11 | 0.00 | -3336.25 | -996.89 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 11-JAN-12:00 | 381124.82 | 0.00 | 0.00 | 0.00 | 3821.78 | 9104.94 | 33300.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -80496.53 | 0.00 | -321750.20 | -25104.91 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Sec1.1A-General InformationData | |
Weather File | Duluth International Arpt MN USA TMY3 WMO#=727450 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 7836.48 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.50 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F2 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F3 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F4 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F6 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F7 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F8 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F9 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 7836.48 | 7059.89 | 776.58 |
Data | |
Number of hours heating loads not met | 109.00 |
Number of hours cooling loads not met | 51.75 |
Number of hours not met | 160.75 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 296.56 | 9104.94 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 162.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 567.85 | 222001.39 | 2181.16 | 329031.97 | 0.00 | 0.00 |
Space Cooling | 144.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 65.89 | 2145.84 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 6.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 631.26 | 20017.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 0.00 | 0.00 | 1343.09 | 86889.94 | 0.00 | 0.00 |
Receptacle Equipment | 1137.32 | 36356.63 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 3048.54 | 3524.24 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 1137.32 | 3048.54 |
Natural Gas | 0.00 | 3524.24 |
Additional | 0.00 | 0.00 |
Total | 1137.32 | 6572.78 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 37.84 |
Space Heating | 72.46 |
Space Cooling | 18.44 |
Fans-Interior | 80.55 |
Service Water Heating | 0.00 |
Receptacle Equipment | 145.13 |
Miscellaneous | 34.58 |
Subtotal | 389.02 |
Natural Gas [MJ/m2] | |
Space Heating | 278.33 |
Service Water Heating | 171.39 |
Miscellaneous | -0.00 |
Subtotal | 449.72 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 4.51 |
Space Heating | 41.82 |
Space Cooling | 2.20 |
Fans-Interior | 9.60 |
Service Water Heating | 20.43 |
Receptacle Equipment | 17.30 |
Miscellaneous | 4.12 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.205722 |
G NW APARTMENT DIRECT AIR | 0.204303 |
OFFICE DIRECT AIR | 0.330758 |
G NE APARTMENT DIRECT AIR | 0.204414 |
G N1 APARTMENT DIRECT AIR | 0.140109 |
G N2 APARTMENT DIRECT AIR | 0.140111 |
G S1 APARTMENT DIRECT AIR | 0.139644 |
G S2 APARTMENT DIRECT AIR | 0.139944 |
F2 SW APARTMENT DIRECT AIR | 0.276460 |
F2 NW APARTMENT DIRECT AIR | 0.246600 |
F2 SE APARTMENT DIRECT AIR | 0.274256 |
F2 NE APARTMENT DIRECT AIR | 0.202350 |
F2 N1 APARTMENT DIRECT AIR | 0.127011 |
F2 N2 APARTMENT DIRECT AIR | 0.125501 |
F2 S1 APARTMENT DIRECT AIR | 0.183383 |
F2 S2 APARTMENT DIRECT AIR | 0.185963 |
F3 SW APARTMENT DIRECT AIR | 0.278474 |
F3 NW APARTMENT DIRECT AIR | 0.250036 |
F3 SE APARTMENT DIRECT AIR | 0.255812 |
F3 NE APARTMENT DIRECT AIR | 0.211032 |
F3 N1 APARTMENT DIRECT AIR | 0.131725 |
F3 N2 APARTMENT DIRECT AIR | 0.130226 |
F3 S1 APARTMENT DIRECT AIR | 0.188013 |
F3 S2 APARTMENT DIRECT AIR | 0.189236 |
F4 SW APARTMENT DIRECT AIR | 0.279135 |
F4 NW APARTMENT DIRECT AIR | 0.251045 |
F4 SE APARTMENT DIRECT AIR | 0.254953 |
F4 NE APARTMENT DIRECT AIR | 0.222077 |
F4 N1 APARTMENT DIRECT AIR | 0.133080 |
F4 N2 APARTMENT DIRECT AIR | 0.131586 |
F4 S1 APARTMENT DIRECT AIR | 0.189255 |
F4 S2 APARTMENT DIRECT AIR | 0.190282 |
M SW APARTMENT DIRECT AIR | 0.281563 |
M NW APARTMENT DIRECT AIR | 0.253763 |
M SE APARTMENT DIRECT AIR | 0.257643 |
M NE APARTMENT DIRECT AIR | 0.230794 |
M N1 APARTMENT DIRECT AIR | 0.135898 |
M N2 APARTMENT DIRECT AIR | 0.134507 |
M S1 APARTMENT DIRECT AIR | 0.192026 |
M S2 APARTMENT DIRECT AIR | 0.193025 |
F6 SW APARTMENT DIRECT AIR | 0.278239 |
F6 NW APARTMENT DIRECT AIR | 0.250466 |
F6 SE APARTMENT DIRECT AIR | 0.254706 |
F6 NE APARTMENT DIRECT AIR | 0.241462 |
F6 N1 APARTMENT DIRECT AIR | 0.141680 |
F6 N2 APARTMENT DIRECT AIR | 0.141666 |
F6 S1 APARTMENT DIRECT AIR | 0.188980 |
F6 S2 APARTMENT DIRECT AIR | 0.189977 |
F7 SW APARTMENT DIRECT AIR | 0.277156 |
F7 NW APARTMENT DIRECT AIR | 0.250708 |
F7 SE APARTMENT DIRECT AIR | 0.253855 |
F7 NE APARTMENT DIRECT AIR | 0.250010 |
F7 N1 APARTMENT DIRECT AIR | 0.147187 |
F7 N2 APARTMENT DIRECT AIR | 0.147172 |
F7 S1 APARTMENT DIRECT AIR | 0.188002 |
F7 S2 APARTMENT DIRECT AIR | 0.188997 |
F8 SW APARTMENT DIRECT AIR | 0.277195 |
F8 NW APARTMENT DIRECT AIR | 0.259051 |
F8 SE APARTMENT DIRECT AIR | 0.257049 |
F8 NE APARTMENT DIRECT AIR | 0.258295 |
F8 N1 APARTMENT DIRECT AIR | 0.152742 |
F8 N2 APARTMENT DIRECT AIR | 0.152725 |
F8 S1 APARTMENT DIRECT AIR | 0.188114 |
F8 S2 APARTMENT DIRECT AIR | 0.189112 |
F9 SW APARTMENT DIRECT AIR | 0.284478 |
F9 NW APARTMENT DIRECT AIR | 0.274327 |
F9 SE APARTMENT DIRECT AIR | 0.272366 |
F9 NE APARTMENT DIRECT AIR | 0.273511 |
F9 N1 APARTMENT DIRECT AIR | 0.164906 |
F9 N2 APARTMENT DIRECT AIR | 0.164888 |
F9 S1 APARTMENT DIRECT AIR | 0.192437 |
F9 S2 APARTMENT DIRECT AIR | 0.193499 |
T SW APARTMENT DIRECT AIR | 0.341153 |
T NW APARTMENT DIRECT AIR | 0.315821 |
T SE APARTMENT DIRECT AIR | 0.313486 |
T NE APARTMENT DIRECT AIR | 0.315021 |
T N1 APARTMENT DIRECT AIR | 0.207738 |
T N2 APARTMENT DIRECT AIR | 0.207719 |
T S1 APARTMENT DIRECT AIR | 0.252502 |
T S2 APARTMENT DIRECT AIR | 0.253492 |
Maximum Flow Rate [m3/s] | |
AIRLOOP G SW MAIN BRANCH | 0.205722 |
AIRLOOP G NW MAIN BRANCH | 0.204303 |
AIRLOOP OFFICE MAIN BRANCH | 0.330758 |
AIRLOOP G NE MAIN BRANCH | 0.204414 |
AIRLOOP G N1 MAIN BRANCH | 0.140109 |
AIRLOOP G N2 MAIN BRANCH | 0.140111 |
AIRLOOP G S1 MAIN BRANCH | 0.139644 |
AIRLOOP G S2 MAIN BRANCH | 0.139944 |
AIRLOOP F2 SW MAIN BRANCH | 0.276460 |
AIRLOOP F2 NW MAIN BRANCH | 0.246600 |
AIRLOOP F2 SE MAIN BRANCH | 0.274256 |
AIRLOOP F2 NE MAIN BRANCH | 0.202350 |
AIRLOOP F2 N1 MAIN BRANCH | 0.127011 |
AIRLOOP F2 N2 MAIN BRANCH | 0.125501 |
AIRLOOP F2 S1 MAIN BRANCH | 0.183383 |
AIRLOOP F2 S2 MAIN BRANCH | 0.185963 |
AIRLOOP F3 SW MAIN BRANCH | 0.278474 |
AIRLOOP F3 NW MAIN BRANCH | 0.250036 |
AIRLOOP F3 SE MAIN BRANCH | 0.255812 |
AIRLOOP F3 NE MAIN BRANCH | 0.211032 |
AIRLOOP F3 N1 MAIN BRANCH | 0.131725 |
AIRLOOP F3 N2 MAIN BRANCH | 0.130226 |
AIRLOOP F3 S1 MAIN BRANCH | 0.188013 |
AIRLOOP F3 S2 MAIN BRANCH | 0.189236 |
AIRLOOP F4 SW MAIN BRANCH | 0.279135 |
AIRLOOP F4 NW MAIN BRANCH | 0.251045 |
AIRLOOP F4 SE MAIN BRANCH | 0.254953 |
AIRLOOP F4 NE MAIN BRANCH | 0.222077 |
AIRLOOP F4 N1 MAIN BRANCH | 0.133080 |
AIRLOOP F4 N2 MAIN BRANCH | 0.131586 |
AIRLOOP F4 S1 MAIN BRANCH | 0.189255 |
AIRLOOP F4 S2 MAIN BRANCH | 0.190282 |
AIRLOOP M SW MAIN BRANCH | 0.281563 |
AIRLOOP M NW MAIN BRANCH | 0.253763 |
AIRLOOP M SE MAIN BRANCH | 0.257643 |
AIRLOOP M NE MAIN BRANCH | 0.230794 |
AIRLOOP M N1 MAIN BRANCH | 0.135898 |
AIRLOOP M N2 MAIN BRANCH | 0.134507 |
AIRLOOP M S1 MAIN BRANCH | 0.192026 |
AIRLOOP M S2 MAIN BRANCH | 0.193025 |
AIRLOOP F6 SW MAIN BRANCH | 0.278239 |
AIRLOOP F6 NW MAIN BRANCH | 0.250466 |
AIRLOOP F6 SE MAIN BRANCH | 0.254706 |
AIRLOOP F6 NE MAIN BRANCH | 0.241462 |
AIRLOOP F6 N1 MAIN BRANCH | 0.141680 |
AIRLOOP F6 N2 MAIN BRANCH | 0.141666 |
AIRLOOP F6 S1 MAIN BRANCH | 0.188980 |
AIRLOOP F6 S2 MAIN BRANCH | 0.189977 |
AIRLOOP F7 SW MAIN BRANCH | 0.277156 |
AIRLOOP F7 NW MAIN BRANCH | 0.250708 |
AIRLOOP F7 SE MAIN BRANCH | 0.253855 |
AIRLOOP F7 NE MAIN BRANCH | 0.250010 |
AIRLOOP F7 N1 MAIN BRANCH | 0.147187 |
AIRLOOP F7 N2 MAIN BRANCH | 0.147172 |
AIRLOOP F7 S1 MAIN BRANCH | 0.188002 |
AIRLOOP F7 S2 MAIN BRANCH | 0.188997 |
AIRLOOP F8 SW MAIN BRANCH | 0.277195 |
AIRLOOP F8 NW MAIN BRANCH | 0.259051 |
AIRLOOP F8 SE MAIN BRANCH | 0.257049 |
AIRLOOP F8 NE MAIN BRANCH | 0.258295 |
AIRLOOP F8 N1 MAIN BRANCH | 0.152742 |
AIRLOOP F8 N2 MAIN BRANCH | 0.152725 |
AIRLOOP F8 S1 MAIN BRANCH | 0.188114 |
AIRLOOP F8 S2 MAIN BRANCH | 0.189112 |
AIRLOOP F9 SW MAIN BRANCH | 0.284478 |
AIRLOOP F9 NW MAIN BRANCH | 0.274327 |
AIRLOOP F9 SE MAIN BRANCH | 0.272366 |
AIRLOOP F9 NE MAIN BRANCH | 0.273511 |
AIRLOOP F9 N1 MAIN BRANCH | 0.164906 |
AIRLOOP F9 N2 MAIN BRANCH | 0.164888 |
AIRLOOP F9 S1 MAIN BRANCH | 0.192437 |
AIRLOOP F9 S2 MAIN BRANCH | 0.193499 |
AIRLOOP T SW MAIN BRANCH | 0.341153 |
AIRLOOP T NW MAIN BRANCH | 0.315821 |
AIRLOOP T SE MAIN BRANCH | 0.313486 |
AIRLOOP T NE MAIN BRANCH | 0.315021 |
AIRLOOP T N1 MAIN BRANCH | 0.207738 |
AIRLOOP T N2 MAIN BRANCH | 0.207719 |
AIRLOOP T S1 MAIN BRANCH | 0.252502 |
AIRLOOP T S2 MAIN BRANCH | 0.253492 |
Design Supply Air Flow Rate [m3/s] | |
AIRLOOP G SW | 0.205722 |
AIRLOOP G NW | 0.204303 |
AIRLOOP OFFICE | 0.330758 |
AIRLOOP G NE | 0.204414 |
AIRLOOP G N1 | 0.140109 |
AIRLOOP G N2 | 0.140111 |
AIRLOOP G S1 | 0.139644 |
AIRLOOP G S2 | 0.139944 |
AIRLOOP F2 SW | 0.276460 |
AIRLOOP F2 NW | 0.246600 |
AIRLOOP F2 SE | 0.274256 |
AIRLOOP F2 NE | 0.202350 |
AIRLOOP F2 N1 | 0.127011 |
AIRLOOP F2 N2 | 0.125501 |
AIRLOOP F2 S1 | 0.183383 |
AIRLOOP F2 S2 | 0.185963 |
AIRLOOP F3 SW | 0.278474 |
AIRLOOP F3 NW | 0.250036 |
AIRLOOP F3 SE | 0.255812 |
AIRLOOP F3 NE | 0.211032 |
AIRLOOP F3 N1 | 0.131725 |
AIRLOOP F3 N2 | 0.130226 |
AIRLOOP F3 S1 | 0.188013 |
AIRLOOP F3 S2 | 0.189236 |
AIRLOOP F4 SW | 0.279135 |
AIRLOOP F4 NW | 0.251045 |
AIRLOOP F4 SE | 0.254953 |
AIRLOOP F4 NE | 0.222077 |
AIRLOOP F4 N1 | 0.133080 |
AIRLOOP F4 N2 | 0.131586 |
AIRLOOP F4 S1 | 0.189255 |
AIRLOOP F4 S2 | 0.190282 |
AIRLOOP M SW | 0.281563 |
AIRLOOP M NW | 0.253763 |
AIRLOOP M SE | 0.257643 |
AIRLOOP M NE | 0.230794 |
AIRLOOP M N1 | 0.135898 |
AIRLOOP M N2 | 0.134507 |
AIRLOOP M S1 | 0.192026 |
AIRLOOP M S2 | 0.193025 |
AIRLOOP F6 SW | 0.278239 |
AIRLOOP F6 NW | 0.250466 |
AIRLOOP F6 SE | 0.254706 |
AIRLOOP F6 NE | 0.241462 |
AIRLOOP F6 N1 | 0.141680 |
AIRLOOP F6 N2 | 0.141666 |
AIRLOOP F6 S1 | 0.188980 |
AIRLOOP F6 S2 | 0.189977 |
AIRLOOP F7 SW | 0.277156 |
AIRLOOP F7 NW | 0.250708 |
AIRLOOP F7 SE | 0.253855 |
AIRLOOP F7 NE | 0.250010 |
AIRLOOP F7 N1 | 0.147187 |
AIRLOOP F7 N2 | 0.147172 |
AIRLOOP F7 S1 | 0.188002 |
AIRLOOP F7 S2 | 0.188997 |
AIRLOOP F8 SW | 0.277195 |
AIRLOOP F8 NW | 0.259051 |
AIRLOOP F8 SE | 0.257049 |
AIRLOOP F8 NE | 0.258295 |
AIRLOOP F8 N1 | 0.152742 |
AIRLOOP F8 N2 | 0.152725 |
AIRLOOP F8 S1 | 0.188114 |
AIRLOOP F8 S2 | 0.189112 |
AIRLOOP F9 SW | 0.284478 |
AIRLOOP F9 NW | 0.274327 |
AIRLOOP F9 SE | 0.272366 |
AIRLOOP F9 NE | 0.273511 |
AIRLOOP F9 N1 | 0.164906 |
AIRLOOP F9 N2 | 0.164888 |
AIRLOOP F9 S1 | 0.192437 |
AIRLOOP F9 S2 | 0.193499 |
AIRLOOP T SW | 0.341153 |
AIRLOOP T NW | 0.315821 |
AIRLOOP T SE | 0.313486 |
AIRLOOP T NE | 0.315021 |
AIRLOOP T N1 | 0.207738 |
AIRLOOP T N2 | 0.207719 |
AIRLOOP T S1 | 0.252502 |
AIRLOOP T S2 | 0.253492 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
AIRLOOP G SW OA CONTROLLER | 0.205722 | 0.025952 |
AIRLOOP G NW OA CONTROLLER | 0.204303 | 0.025952 |
AIRLOOP OFFICE OA CONTROLLER | 0.330758 | 0.038103 |
AIRLOOP G NE OA CONTROLLER | 0.204414 | 0.025952 |
AIRLOOP G N1 OA CONTROLLER | 0.140109 | 0.025952 |
AIRLOOP G N2 OA CONTROLLER | 0.140111 | 0.025952 |
AIRLOOP G S1 OA CONTROLLER | 0.139644 | 0.025952 |
AIRLOOP G S2 OA CONTROLLER | 0.139944 | 0.025952 |
AIRLOOP F2 SW OA CONTROLLER | 0.276460 | 0.025952 |
AIRLOOP F2 NW OA CONTROLLER | 0.246600 | 0.025952 |
AIRLOOP F2 SE OA CONTROLLER | 0.274256 | 0.025952 |
AIRLOOP F2 NE OA CONTROLLER | 0.202350 | 0.025952 |
AIRLOOP F2 N1 OA CONTROLLER | 0.127011 | 0.025952 |
AIRLOOP F2 N2 OA CONTROLLER | 0.125501 | 0.025952 |
AIRLOOP F2 S1 OA CONTROLLER | 0.183383 | 0.025952 |
AIRLOOP F2 S2 OA CONTROLLER | 0.185963 | 0.025952 |
AIRLOOP F3 SW OA CONTROLLER | 0.278474 | 0.025952 |
AIRLOOP F3 NW OA CONTROLLER | 0.250036 | 0.025952 |
AIRLOOP F3 SE OA CONTROLLER | 0.255812 | 0.025952 |
AIRLOOP F3 NE OA CONTROLLER | 0.211032 | 0.025952 |
AIRLOOP F3 N1 OA CONTROLLER | 0.131725 | 0.025952 |
AIRLOOP F3 N2 OA CONTROLLER | 0.130226 | 0.025952 |
AIRLOOP F3 S1 OA CONTROLLER | 0.188013 | 0.025952 |
AIRLOOP F3 S2 OA CONTROLLER | 0.189236 | 0.025952 |
AIRLOOP F4 SW OA CONTROLLER | 0.279135 | 0.025952 |
AIRLOOP F4 NW OA CONTROLLER | 0.251045 | 0.025952 |
AIRLOOP F4 SE OA CONTROLLER | 0.254953 | 0.025952 |
AIRLOOP F4 NE OA CONTROLLER | 0.222077 | 0.025952 |
AIRLOOP F4 N1 OA CONTROLLER | 0.133080 | 0.025952 |
AIRLOOP F4 N2 OA CONTROLLER | 0.131586 | 0.025952 |
AIRLOOP F4 S1 OA CONTROLLER | 0.189255 | 0.025952 |
AIRLOOP F4 S2 OA CONTROLLER | 0.190282 | 0.025952 |
AIRLOOP M SW OA CONTROLLER | 0.281563 | 0.025952 |
AIRLOOP M NW OA CONTROLLER | 0.253763 | 0.025952 |
AIRLOOP M SE OA CONTROLLER | 0.257643 | 0.025952 |
AIRLOOP M NE OA CONTROLLER | 0.230794 | 0.025952 |
AIRLOOP M N1 OA CONTROLLER | 0.135898 | 0.025952 |
AIRLOOP M N2 OA CONTROLLER | 0.134507 | 0.025952 |
AIRLOOP M S1 OA CONTROLLER | 0.192026 | 0.025952 |
AIRLOOP M S2 OA CONTROLLER | 0.193025 | 0.025952 |
AIRLOOP F6 SW OA CONTROLLER | 0.278239 | 0.025952 |
AIRLOOP F6 NW OA CONTROLLER | 0.250466 | 0.025952 |
AIRLOOP F6 SE OA CONTROLLER | 0.254706 | 0.025952 |
AIRLOOP F6 NE OA CONTROLLER | 0.241462 | 0.025952 |
AIRLOOP F6 N1 OA CONTROLLER | 0.141680 | 0.025952 |
AIRLOOP F6 N2 OA CONTROLLER | 0.141666 | 0.025952 |
AIRLOOP F6 S1 OA CONTROLLER | 0.188980 | 0.025952 |
AIRLOOP F6 S2 OA CONTROLLER | 0.189977 | 0.025952 |
AIRLOOP F7 SW OA CONTROLLER | 0.277156 | 0.025952 |
AIRLOOP F7 NW OA CONTROLLER | 0.250708 | 0.025952 |
AIRLOOP F7 SE OA CONTROLLER | 0.253855 | 0.025952 |
AIRLOOP F7 NE OA CONTROLLER | 0.250010 | 0.025952 |
AIRLOOP F7 N1 OA CONTROLLER | 0.147187 | 0.025952 |
AIRLOOP F7 N2 OA CONTROLLER | 0.147172 | 0.025952 |
AIRLOOP F7 S1 OA CONTROLLER | 0.188002 | 0.025952 |
AIRLOOP F7 S2 OA CONTROLLER | 0.188997 | 0.025952 |
AIRLOOP F8 SW OA CONTROLLER | 0.277195 | 0.025952 |
AIRLOOP F8 NW OA CONTROLLER | 0.259051 | 0.025952 |
AIRLOOP F8 SE OA CONTROLLER | 0.257049 | 0.025952 |
AIRLOOP F8 NE OA CONTROLLER | 0.258295 | 0.025952 |
AIRLOOP F8 N1 OA CONTROLLER | 0.152742 | 0.025952 |
AIRLOOP F8 N2 OA CONTROLLER | 0.152725 | 0.025952 |
AIRLOOP F8 S1 OA CONTROLLER | 0.188114 | 0.025952 |
AIRLOOP F8 S2 OA CONTROLLER | 0.189112 | 0.025952 |
AIRLOOP F9 SW OA CONTROLLER | 0.284478 | 0.025952 |
AIRLOOP F9 NW OA CONTROLLER | 0.274327 | 0.025952 |
AIRLOOP F9 SE OA CONTROLLER | 0.272366 | 0.025952 |
AIRLOOP F9 NE OA CONTROLLER | 0.273511 | 0.025952 |
AIRLOOP F9 N1 OA CONTROLLER | 0.164906 | 0.025952 |
AIRLOOP F9 N2 OA CONTROLLER | 0.164888 | 0.025952 |
AIRLOOP F9 S1 OA CONTROLLER | 0.192437 | 0.025952 |
AIRLOOP F9 S2 OA CONTROLLER | 0.193499 | 0.025952 |
AIRLOOP T SW OA CONTROLLER | 0.341153 | 0.025952 |
AIRLOOP T NW OA CONTROLLER | 0.315821 | 0.025952 |
AIRLOOP T SE OA CONTROLLER | 0.313486 | 0.025952 |
AIRLOOP T NE OA CONTROLLER | 0.315021 | 0.025952 |
AIRLOOP T N1 OA CONTROLLER | 0.207738 | 0.025952 |
AIRLOOP T N2 OA CONTROLLER | 0.207719 | 0.025952 |
AIRLOOP T S1 OA CONTROLLER | 0.252502 | 0.025952 |
AIRLOOP T S2 OA CONTROLLER | 0.253492 | 0.025952 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity [W] | Rated Sensible Cooling Capacity [W] | Rated Water Flow Rate [m3/s] | |
HEAT PUMP COOLING MODE AIRLOOP G SW | 0.205722 | 3494.72 | 2266.68 | 0.000076 |
HEAT PUMP COOLING MODE AIRLOOP G NW | 0.204303 | 3510.52 | 2253.89 | 0.000077 |
HEAT PUMP COOLING MODE AIRLOOP OFFICE | 0.330758 | 5429.48 | 3594.63 | 0.000119 |
HEAT PUMP COOLING MODE AIRLOOP G NE | 0.204414 | 3735.54 | 2316.37 | 0.000082 |
HEAT PUMP COOLING MODE AIRLOOP G N1 | 0.140109 | 2734.62 | 1641.03 | 0.000060 |
HEAT PUMP COOLING MODE AIRLOOP G N2 | 0.140111 | 2748.65 | 1645.72 | 0.000060 |
HEAT PUMP COOLING MODE AIRLOOP G S1 | 0.139644 | 2553.60 | 1601.76 | 0.000056 |
HEAT PUMP COOLING MODE AIRLOOP G S2 | 0.139944 | 2529.13 | 1595.37 | 0.000055 |
HEAT PUMP COOLING MODE AIRLOOP F2 SW | 0.276460 | 4535.68 | 2987.25 | 0.000099 |
HEAT PUMP COOLING MODE AIRLOOP F2 NW | 0.246600 | 4106.48 | 2677.26 | 0.000090 |
HEAT PUMP COOLING MODE AIRLOOP F2 SE | 0.274256 | 4544.68 | 2986.41 | 0.000099 |
HEAT PUMP COOLING MODE AIRLOOP F2 NE | 0.202350 | 3520.63 | 2237.83 | 0.000077 |
HEAT PUMP COOLING MODE AIRLOOP F2 N1 | 0.127011 | 2311.88 | 1433.75 | 0.000051 |
HEAT PUMP COOLING MODE AIRLOOP F2 N2 | 0.125501 | 2290.15 | 1418.48 | 0.000050 |
HEAT PUMP COOLING MODE AIRLOOP F2 S1 | 0.183383 | 3179.81 | 2044.87 | 0.000069 |
HEAT PUMP COOLING MODE AIRLOOP F2 S2 | 0.185963 | 3215.43 | 2070.74 | 0.000070 |
HEAT PUMP COOLING MODE AIRLOOP F3 SW | 0.278474 | 4615.28 | 3021.57 | 0.000101 |
HEAT PUMP COOLING MODE AIRLOOP F3 NW | 0.250036 | 4214.15 | 2730.82 | 0.000092 |
HEAT PUMP COOLING MODE AIRLOOP F3 SE | 0.255812 | 4339.47 | 2814.85 | 0.000095 |
HEAT PUMP COOLING MODE AIRLOOP F3 NE | 0.211032 | 3707.02 | 2343.93 | 0.000081 |
HEAT PUMP COOLING MODE AIRLOOP F3 N1 | 0.131725 | 2404.18 | 1488.82 | 0.000053 |
HEAT PUMP COOLING MODE AIRLOOP F3 N2 | 0.130226 | 2382.52 | 1473.64 | 0.000052 |
HEAT PUMP COOLING MODE AIRLOOP F3 S1 | 0.188013 | 3273.79 | 2099.72 | 0.000072 |
HEAT PUMP COOLING MODE AIRLOOP F3 S2 | 0.189236 | 3290.67 | 2111.98 | 0.000072 |
HEAT PUMP COOLING MODE AIRLOOP F4 SW | 0.279135 | 4662.50 | 3038.66 | 0.000102 |
HEAT PUMP COOLING MODE AIRLOOP F4 NW | 0.251045 | 4264.62 | 2751.14 | 0.000093 |
HEAT PUMP COOLING MODE AIRLOOP F4 SE | 0.254953 | 4364.16 | 2816.41 | 0.000095 |
HEAT PUMP COOLING MODE AIRLOOP F4 NE | 0.222077 | 3937.18 | 2477.15 | 0.000086 |
HEAT PUMP COOLING MODE AIRLOOP F4 N1 | 0.133080 | 2441.97 | 1508.07 | 0.000053 |
HEAT PUMP COOLING MODE AIRLOOP F4 N2 | 0.131586 | 2420.29 | 1492.93 | 0.000053 |
HEAT PUMP COOLING MODE AIRLOOP F4 S1 | 0.189255 | 3313.17 | 2118.44 | 0.000072 |
HEAT PUMP COOLING MODE AIRLOOP F4 S2 | 0.190282 | 3327.37 | 2128.73 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP M SW | 0.281563 | 4727.00 | 3071.57 | 0.000103 |
HEAT PUMP COOLING MODE AIRLOOP M NW | 0.253763 | 4331.99 | 2786.74 | 0.000095 |
HEAT PUMP COOLING MODE AIRLOOP M SE | 0.257643 | 4431.34 | 2851.77 | 0.000097 |
HEAT PUMP COOLING MODE AIRLOOP M NE | 0.230794 | 4113.64 | 2580.76 | 0.000090 |
HEAT PUMP COOLING MODE AIRLOOP M N1 | 0.135898 | 2497.40 | 1541.08 | 0.000055 |
HEAT PUMP COOLING MODE AIRLOOP M N2 | 0.134507 | 2477.54 | 1527.09 | 0.000054 |
HEAT PUMP COOLING MODE AIRLOOP M S1 | 0.192026 | 3369.75 | 2151.38 | 0.000074 |
HEAT PUMP COOLING MODE AIRLOOP M S2 | 0.193025 | 3383.58 | 2161.40 | 0.000074 |
HEAT PUMP COOLING MODE AIRLOOP F6 SW | 0.278239 | 4724.80 | 3056.08 | 0.000103 |
HEAT PUMP COOLING MODE AIRLOOP F6 NW | 0.250466 | 4310.11 | 2760.44 | 0.000094 |
HEAT PUMP COOLING MODE AIRLOOP F6 SE | 0.254706 | 4414.82 | 2829.13 | 0.000096 |
HEAT PUMP COOLING MODE AIRLOOP F6 NE | 0.241462 | 4357.64 | 2719.10 | 0.000095 |
HEAT PUMP COOLING MODE AIRLOOP F6 N1 | 0.141680 | 2628.86 | 1614.47 | 0.000057 |
HEAT PUMP COOLING MODE AIRLOOP F6 N2 | 0.141666 | 2634.80 | 1616.26 | 0.000058 |
HEAT PUMP COOLING MODE AIRLOOP F6 S1 | 0.188980 | 3342.16 | 2125.01 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F6 S2 | 0.189977 | 3355.99 | 2135.01 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F7 SW | 0.277156 | 4731.90 | 3051.39 | 0.000103 |
HEAT PUMP COOLING MODE AIRLOOP F7 NW | 0.250708 | 4338.99 | 2770.20 | 0.000095 |
HEAT PUMP COOLING MODE AIRLOOP F7 SE | 0.253855 | 4424.29 | 2826.63 | 0.000097 |
HEAT PUMP COOLING MODE AIRLOOP F7 NE | 0.250010 | 4542.98 | 2824.74 | 0.000099 |
HEAT PUMP COOLING MODE AIRLOOP F7 N1 | 0.147187 | 2746.72 | 1682.11 | 0.000060 |
HEAT PUMP COOLING MODE AIRLOOP F7 N2 | 0.147172 | 2752.95 | 1684.00 | 0.000060 |
HEAT PUMP COOLING MODE AIRLOOP F7 S1 | 0.188002 | 3341.47 | 2118.90 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F7 S2 | 0.188997 | 3355.33 | 2128.89 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F8 SW | 0.277195 | 4752.25 | 3057.35 | 0.000104 |
HEAT PUMP COOLING MODE AIRLOOP F8 NW | 0.259051 | 4502.70 | 2867.92 | 0.000098 |
HEAT PUMP COOLING MODE AIRLOOP F8 SE | 0.257049 | 4498.51 | 2867.45 | 0.000098 |
HEAT PUMP COOLING MODE AIRLOOP F8 NE | 0.258295 | 4717.07 | 2925.45 | 0.000103 |
HEAT PUMP COOLING MODE AIRLOOP F8 N1 | 0.152742 | 2859.93 | 1748.56 | 0.000062 |
HEAT PUMP COOLING MODE AIRLOOP F8 N2 | 0.152725 | 2866.33 | 1750.50 | 0.000063 |
HEAT PUMP COOLING MODE AIRLOOP F8 S1 | 0.188114 | 3354.68 | 2123.37 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F8 S2 | 0.189112 | 3368.59 | 2133.39 | 0.000074 |
HEAT PUMP COOLING MODE AIRLOOP F9 SW | 0.284478 | 4854.53 | 3125.15 | 0.000106 |
HEAT PUMP COOLING MODE AIRLOOP F9 NW | 0.274327 | 4762.06 | 3034.87 | 0.000104 |
HEAT PUMP COOLING MODE AIRLOOP F9 SE | 0.272366 | 4768.51 | 3039.08 | 0.000104 |
HEAT PUMP COOLING MODE AIRLOOP F9 NE | 0.273511 | 5004.16 | 3100.42 | 0.000109 |
HEAT PUMP COOLING MODE AIRLOOP F9 N1 | 0.164906 | 3067.86 | 1881.47 | 0.000067 |
HEAT PUMP COOLING MODE AIRLOOP F9 N2 | 0.164888 | 3074.38 | 1883.43 | 0.000067 |
HEAT PUMP COOLING MODE AIRLOOP F9 S1 | 0.192437 | 3428.79 | 2171.46 | 0.000075 |
HEAT PUMP COOLING MODE AIRLOOP F9 S2 | 0.193499 | 3441.45 | 2180.80 | 0.000075 |
HEAT PUMP COOLING MODE AIRLOOP T SW | 0.341153 | 5702.34 | 3721.46 | 0.000125 |
HEAT PUMP COOLING MODE AIRLOOP T NW | 0.315821 | 5362.38 | 3461.01 | 0.000117 |
HEAT PUMP COOLING MODE AIRLOOP T SE | 0.313486 | 5332.29 | 3448.08 | 0.000116 |
HEAT PUMP COOLING MODE AIRLOOP T NE | 0.315021 | 5603.29 | 3524.05 | 0.000122 |
HEAT PUMP COOLING MODE AIRLOOP T N1 | 0.207738 | 3839.49 | 2388.13 | 0.000084 |
HEAT PUMP COOLING MODE AIRLOOP T N2 | 0.207719 | 3845.33 | 2390.75 | 0.000084 |
HEAT PUMP COOLING MODE AIRLOOP T S1 | 0.252502 | 4277.30 | 2777.85 | 0.000093 |
HEAT PUMP COOLING MODE AIRLOOP T S2 | 0.253492 | 4290.87 | 2787.76 | 0.000094 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Supplemental Heating Coil Nominal Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
AIRLOOP G SW DXAC HEAT PUMP | 0.205722 | 0.205722 | 0.205722 | 0.205722 | 3494.72 | 3494.72 | 5790.18 | 1.00 |
AIRLOOP G NW DXAC HEAT PUMP | 0.204303 | 0.204303 | 0.204303 | 0.204303 | 3510.52 | 3510.52 | 5797.70 | 1.00 |
AIRLOOP OFFICE DXAC HEAT PUMP | 0.330758 | 0.330758 | 0.330758 | 0.330758 | 5429.48 | 5429.48 | 6934.29 | 1.00 |
AIRLOOP G NE DXAC HEAT PUMP | 0.204414 | 0.204414 | 0.204414 | 0.204414 | 3735.54 | 3735.54 | 5800.02 | 1.00 |
AIRLOOP G N1 DXAC HEAT PUMP | 0.140109 | 0.140109 | 0.140109 | 0.140109 | 2734.62 | 2734.62 | 4447.31 | 1.00 |
AIRLOOP G N2 DXAC HEAT PUMP | 0.140111 | 0.140111 | 0.140111 | 0.140111 | 2748.65 | 2748.65 | 4447.35 | 1.00 |
AIRLOOP G S1 DXAC HEAT PUMP | 0.139644 | 0.139644 | 0.139644 | 0.139644 | 2553.60 | 2553.60 | 4437.51 | 1.00 |
AIRLOOP G S2 DXAC HEAT PUMP | 0.139944 | 0.139944 | 0.139944 | 0.139944 | 2529.13 | 2529.13 | 4443.83 | 1.00 |
AIRLOOP F2 SW DXAC HEAT PUMP | 0.276460 | 0.276460 | 0.276460 | 0.276460 | 4535.68 | 4535.68 | 5756.77 | 1.00 |
AIRLOOP F2 NW DXAC HEAT PUMP | 0.246600 | 0.246600 | 0.246600 | 0.246600 | 4106.48 | 4106.48 | 5760.11 | 1.00 |
AIRLOOP F2 SE DXAC HEAT PUMP | 0.274256 | 0.274256 | 0.274256 | 0.274256 | 4544.68 | 4544.68 | 5771.78 | 1.00 |
AIRLOOP F2 NE DXAC HEAT PUMP | 0.202350 | 0.202350 | 0.202350 | 0.202350 | 3520.63 | 3520.63 | 5757.17 | 1.00 |
AIRLOOP F2 N1 DXAC HEAT PUMP | 0.127011 | 0.127011 | 0.127011 | 0.127011 | 2311.88 | 2311.88 | 4049.99 | 1.00 |
AIRLOOP F2 N2 DXAC HEAT PUMP | 0.125501 | 0.125501 | 0.125501 | 0.125501 | 2290.15 | 2290.15 | 4049.93 | 1.00 |
AIRLOOP F2 S1 DXAC HEAT PUMP | 0.183383 | 0.183383 | 0.183383 | 0.183383 | 3179.81 | 3179.81 | 4049.80 | 1.00 |
AIRLOOP F2 S2 DXAC HEAT PUMP | 0.185963 | 0.185963 | 0.185963 | 0.185963 | 3215.43 | 3215.43 | 4050.82 | 1.00 |
AIRLOOP F3 SW DXAC HEAT PUMP | 0.278474 | 0.278474 | 0.278474 | 0.278474 | 4615.28 | 4615.28 | 5934.99 | 1.00 |
AIRLOOP F3 NW DXAC HEAT PUMP | 0.250036 | 0.250036 | 0.250036 | 0.250036 | 4214.15 | 4214.15 | 5946.68 | 1.00 |
AIRLOOP F3 SE DXAC HEAT PUMP | 0.255812 | 0.255812 | 0.255812 | 0.255812 | 4339.47 | 4339.47 | 5930.08 | 1.00 |
AIRLOOP F3 NE DXAC HEAT PUMP | 0.211032 | 0.211032 | 0.211032 | 0.211032 | 3707.02 | 3707.02 | 5939.98 | 1.00 |
AIRLOOP F3 N1 DXAC HEAT PUMP | 0.131725 | 0.131725 | 0.131725 | 0.131725 | 2404.18 | 2404.18 | 4101.16 | 1.00 |
AIRLOOP F3 N2 DXAC HEAT PUMP | 0.130226 | 0.130226 | 0.130226 | 0.130226 | 2382.52 | 2382.52 | 4101.01 | 1.00 |
AIRLOOP F3 S1 DXAC HEAT PUMP | 0.188013 | 0.188013 | 0.188013 | 0.188013 | 3273.79 | 3273.79 | 4090.68 | 1.00 |
AIRLOOP F3 S2 DXAC HEAT PUMP | 0.189236 | 0.189236 | 0.189236 | 0.189236 | 3290.67 | 3290.67 | 4090.69 | 1.00 |
AIRLOOP F4 SW DXAC HEAT PUMP | 0.279135 | 0.279135 | 0.279135 | 0.279135 | 4662.50 | 4662.50 | 6165.08 | 1.00 |
AIRLOOP F4 NW DXAC HEAT PUMP | 0.251045 | 0.251045 | 0.251045 | 0.251045 | 4264.62 | 4264.62 | 6181.89 | 1.00 |
AIRLOOP F4 SE DXAC HEAT PUMP | 0.254953 | 0.254953 | 0.254953 | 0.254953 | 4364.16 | 4364.16 | 6155.84 | 1.00 |
AIRLOOP F4 NE DXAC HEAT PUMP | 0.222077 | 0.222077 | 0.222077 | 0.222077 | 3937.18 | 3937.18 | 6172.48 | 1.00 |
AIRLOOP F4 N1 DXAC HEAT PUMP | 0.133080 | 0.133080 | 0.133080 | 0.133080 | 2441.97 | 2441.97 | 4230.13 | 1.00 |
AIRLOOP F4 N2 DXAC HEAT PUMP | 0.131586 | 0.131586 | 0.131586 | 0.131586 | 2420.29 | 2420.29 | 4229.93 | 1.00 |
AIRLOOP F4 S1 DXAC HEAT PUMP | 0.189255 | 0.189255 | 0.189255 | 0.189255 | 3313.17 | 3313.17 | 4214.22 | 1.00 |
AIRLOOP F4 S2 DXAC HEAT PUMP | 0.190282 | 0.190282 | 0.190282 | 0.190282 | 3327.37 | 3327.37 | 4214.03 | 1.00 |
AIRLOOP M SW DXAC HEAT PUMP | 0.281563 | 0.281563 | 0.281563 | 0.281563 | 4727.00 | 4727.00 | 6348.25 | 1.00 |
AIRLOOP M NW DXAC HEAT PUMP | 0.253763 | 0.253763 | 0.253763 | 0.253763 | 4331.99 | 4331.99 | 6367.52 | 1.00 |
AIRLOOP M SE DXAC HEAT PUMP | 0.257643 | 0.257643 | 0.257643 | 0.257643 | 4431.34 | 4431.34 | 6336.76 | 1.00 |
AIRLOOP M NE DXAC HEAT PUMP | 0.230794 | 0.230794 | 0.230794 | 0.230794 | 4113.64 | 4113.64 | 6356.00 | 1.00 |
AIRLOOP M N1 DXAC HEAT PUMP | 0.135898 | 0.135898 | 0.135898 | 0.135898 | 2497.40 | 2497.40 | 4330.10 | 1.00 |
AIRLOOP M N2 DXAC HEAT PUMP | 0.134507 | 0.134507 | 0.134507 | 0.134507 | 2477.54 | 2477.54 | 4329.84 | 1.00 |
AIRLOOP M S1 DXAC HEAT PUMP | 0.192026 | 0.192026 | 0.192026 | 0.192026 | 3369.75 | 3369.75 | 4311.63 | 1.00 |
AIRLOOP M S2 DXAC HEAT PUMP | 0.193025 | 0.193025 | 0.193025 | 0.193025 | 3383.58 | 3383.58 | 4311.38 | 1.00 |
AIRLOOP F6 SW DXAC HEAT PUMP | 0.278239 | 0.278239 | 0.278239 | 0.278239 | 4724.80 | 4724.80 | 6570.94 | 1.00 |
AIRLOOP F6 NW DXAC HEAT PUMP | 0.250466 | 0.250466 | 0.250466 | 0.250466 | 4310.11 | 4310.11 | 6593.79 | 1.00 |
AIRLOOP F6 SE DXAC HEAT PUMP | 0.254706 | 0.254706 | 0.254706 | 0.254706 | 4414.82 | 4414.82 | 6557.70 | 1.00 |
AIRLOOP F6 NE DXAC HEAT PUMP | 0.241462 | 0.241462 | 0.241462 | 0.241462 | 4357.64 | 4357.64 | 6580.55 | 1.00 |
AIRLOOP F6 N1 DXAC HEAT PUMP | 0.141680 | 0.141680 | 0.141680 | 0.141680 | 2628.86 | 2628.86 | 4480.77 | 1.00 |
AIRLOOP F6 N2 DXAC HEAT PUMP | 0.141666 | 0.141666 | 0.141666 | 0.141666 | 2634.80 | 2634.80 | 4480.48 | 1.00 |
AIRLOOP F6 S1 DXAC HEAT PUMP | 0.188980 | 0.188980 | 0.188980 | 0.188980 | 3342.16 | 3342.16 | 4458.67 | 1.00 |
AIRLOOP F6 S2 DXAC HEAT PUMP | 0.189977 | 0.189977 | 0.189977 | 0.189977 | 3355.99 | 3355.99 | 4458.38 | 1.00 |
AIRLOOP F7 SW DXAC HEAT PUMP | 0.277156 | 0.277156 | 0.277156 | 0.277156 | 4731.90 | 4731.90 | 6750.30 | 1.00 |
AIRLOOP F7 NW DXAC HEAT PUMP | 0.250708 | 0.250708 | 0.250708 | 0.250708 | 4338.99 | 4338.99 | 6775.17 | 1.00 |
AIRLOOP F7 SE DXAC HEAT PUMP | 0.253855 | 0.253855 | 0.253855 | 0.253855 | 4424.29 | 4424.29 | 6735.63 | 1.00 |
AIRLOOP F7 NE DXAC HEAT PUMP | 0.250010 | 0.250010 | 0.250010 | 0.250010 | 4542.98 | 4542.98 | 6760.49 | 1.00 |
AIRLOOP F7 N1 DXAC HEAT PUMP | 0.147187 | 0.147187 | 0.147187 | 0.147187 | 2746.72 | 2746.72 | 4596.67 | 1.00 |
AIRLOOP F7 N2 DXAC HEAT PUMP | 0.147172 | 0.147172 | 0.147172 | 0.147172 | 2752.95 | 2752.95 | 4596.35 | 1.00 |
AIRLOOP F7 S1 DXAC HEAT PUMP | 0.188002 | 0.188002 | 0.188002 | 0.188002 | 3341.47 | 3341.47 | 4572.53 | 1.00 |
AIRLOOP F7 S2 DXAC HEAT PUMP | 0.188997 | 0.188997 | 0.188997 | 0.188997 | 3355.33 | 3355.33 | 4572.21 | 1.00 |
AIRLOOP F8 SW DXAC HEAT PUMP | 0.277195 | 0.277195 | 0.277195 | 0.277195 | 4752.25 | 4752.25 | 6924.59 | 1.00 |
AIRLOOP F8 NW DXAC HEAT PUMP | 0.259051 | 0.259051 | 0.259051 | 0.259051 | 4502.70 | 4502.70 | 6950.81 | 1.00 |
AIRLOOP F8 SE DXAC HEAT PUMP | 0.257049 | 0.257049 | 0.257049 | 0.257049 | 4498.51 | 4498.51 | 6908.67 | 1.00 |
AIRLOOP F8 NE DXAC HEAT PUMP | 0.258295 | 0.258295 | 0.258295 | 0.258295 | 4717.07 | 4717.07 | 6934.89 | 1.00 |
AIRLOOP F8 N1 DXAC HEAT PUMP | 0.152742 | 0.152742 | 0.152742 | 0.152742 | 2859.93 | 2859.93 | 4713.56 | 1.00 |
AIRLOOP F8 N2 DXAC HEAT PUMP | 0.152725 | 0.152725 | 0.152725 | 0.152725 | 2866.33 | 2866.33 | 4713.21 | 1.00 |
AIRLOOP F8 S1 DXAC HEAT PUMP | 0.188114 | 0.188114 | 0.188114 | 0.188114 | 3354.68 | 3354.68 | 4688.06 | 1.00 |
AIRLOOP F8 S2 DXAC HEAT PUMP | 0.189112 | 0.189112 | 0.189112 | 0.189112 | 3368.59 | 3368.59 | 4687.71 | 1.00 |
AIRLOOP F9 SW DXAC HEAT PUMP | 0.284478 | 0.284478 | 0.284478 | 0.284478 | 4854.53 | 4854.53 | 7248.20 | 1.00 |
AIRLOOP F9 NW DXAC HEAT PUMP | 0.274327 | 0.274327 | 0.274327 | 0.274327 | 4762.06 | 4762.06 | 7272.28 | 1.00 |
AIRLOOP F9 SE DXAC HEAT PUMP | 0.272366 | 0.272366 | 0.272366 | 0.272366 | 4768.51 | 4768.51 | 7231.03 | 1.00 |
AIRLOOP F9 NE DXAC HEAT PUMP | 0.273511 | 0.273511 | 0.273511 | 0.273511 | 5004.16 | 5004.16 | 7255.12 | 1.00 |
AIRLOOP F9 N1 DXAC HEAT PUMP | 0.164906 | 0.164906 | 0.164906 | 0.164906 | 3067.86 | 3067.86 | 4969.48 | 1.00 |
AIRLOOP F9 N2 DXAC HEAT PUMP | 0.164888 | 0.164888 | 0.164888 | 0.164888 | 3074.38 | 3074.38 | 4969.10 | 1.00 |
AIRLOOP F9 S1 DXAC HEAT PUMP | 0.192437 | 0.192437 | 0.192437 | 0.192437 | 3428.79 | 3428.79 | 4945.66 | 1.00 |
AIRLOOP F9 S2 DXAC HEAT PUMP | 0.193499 | 0.193499 | 0.193499 | 0.193499 | 3441.45 | 3441.45 | 4945.28 | 1.00 |
AIRLOOP T SW DXAC HEAT PUMP | 0.341153 | 0.341153 | 0.341153 | 0.341153 | 5702.34 | 5702.34 | 8113.34 | 1.00 |
AIRLOOP T NW DXAC HEAT PUMP | 0.315821 | 0.315821 | 0.315821 | 0.315821 | 5362.38 | 5362.38 | 8145.63 | 1.00 |
AIRLOOP T SE DXAC HEAT PUMP | 0.313486 | 0.313486 | 0.313486 | 0.313486 | 5332.29 | 5332.29 | 8096.51 | 1.00 |
AIRLOOP T NE DXAC HEAT PUMP | 0.315021 | 0.315021 | 0.315021 | 0.315021 | 5603.29 | 5603.29 | 8128.80 | 1.00 |
AIRLOOP T N1 DXAC HEAT PUMP | 0.207738 | 0.207738 | 0.207738 | 0.207738 | 3839.49 | 3839.49 | 5870.68 | 1.00 |
AIRLOOP T N2 DXAC HEAT PUMP | 0.207719 | 0.207719 | 0.207719 | 0.207719 | 3845.33 | 3845.33 | 5870.29 | 1.00 |
AIRLOOP T S1 DXAC HEAT PUMP | 0.252502 | 0.252502 | 0.252502 | 0.252502 | 4277.30 | 4277.30 | 5835.47 | 1.00 |
AIRLOOP T S2 DXAC HEAT PUMP | 0.253492 | 0.253492 | 0.253492 | 0.253492 | 4290.87 | 4290.87 | 5835.08 | 1.00 |
Maximum Flow Rate [m3/s] | |
AIRLOOP G SW SUPPLY FAN | 0.205722 |
AIRLOOP G NW SUPPLY FAN | 0.204303 |
AIRLOOP OFFICE SUPPLY FAN | 0.330758 |
AIRLOOP G NE SUPPLY FAN | 0.204414 |
AIRLOOP G N1 SUPPLY FAN | 0.140109 |
AIRLOOP G N2 SUPPLY FAN | 0.140111 |
AIRLOOP G S1 SUPPLY FAN | 0.139644 |
AIRLOOP G S2 SUPPLY FAN | 0.139944 |
AIRLOOP F2 SW SUPPLY FAN | 0.276460 |
AIRLOOP F2 NW SUPPLY FAN | 0.246600 |
AIRLOOP F2 SE SUPPLY FAN | 0.274256 |
AIRLOOP F2 NE SUPPLY FAN | 0.202350 |
AIRLOOP F2 N1 SUPPLY FAN | 0.127011 |
AIRLOOP F2 N2 SUPPLY FAN | 0.125501 |
AIRLOOP F2 S1 SUPPLY FAN | 0.183383 |
AIRLOOP F2 S2 SUPPLY FAN | 0.185963 |
AIRLOOP F3 SW SUPPLY FAN | 0.278474 |
AIRLOOP F3 NW SUPPLY FAN | 0.250036 |
AIRLOOP F3 SE SUPPLY FAN | 0.255812 |
AIRLOOP F3 NE SUPPLY FAN | 0.211032 |
AIRLOOP F3 N1 SUPPLY FAN | 0.131725 |
AIRLOOP F3 N2 SUPPLY FAN | 0.130226 |
AIRLOOP F3 S1 SUPPLY FAN | 0.188013 |
AIRLOOP F3 S2 SUPPLY FAN | 0.189236 |
AIRLOOP F4 SW SUPPLY FAN | 0.279135 |
AIRLOOP F4 NW SUPPLY FAN | 0.251045 |
AIRLOOP F4 SE SUPPLY FAN | 0.254953 |
AIRLOOP F4 NE SUPPLY FAN | 0.222077 |
AIRLOOP F4 N1 SUPPLY FAN | 0.133080 |
AIRLOOP F4 N2 SUPPLY FAN | 0.131586 |
AIRLOOP F4 S1 SUPPLY FAN | 0.189255 |
AIRLOOP F4 S2 SUPPLY FAN | 0.190282 |
AIRLOOP M SW SUPPLY FAN | 0.281563 |
AIRLOOP M NW SUPPLY FAN | 0.253763 |
AIRLOOP M SE SUPPLY FAN | 0.257643 |
AIRLOOP M NE SUPPLY FAN | 0.230794 |
AIRLOOP M N1 SUPPLY FAN | 0.135898 |
AIRLOOP M N2 SUPPLY FAN | 0.134507 |
AIRLOOP M S1 SUPPLY FAN | 0.192026 |
AIRLOOP M S2 SUPPLY FAN | 0.193025 |
AIRLOOP F6 SW SUPPLY FAN | 0.278239 |
AIRLOOP F6 NW SUPPLY FAN | 0.250466 |
AIRLOOP F6 SE SUPPLY FAN | 0.254706 |
AIRLOOP F6 NE SUPPLY FAN | 0.241462 |
AIRLOOP F6 N1 SUPPLY FAN | 0.141680 |
AIRLOOP F6 N2 SUPPLY FAN | 0.141666 |
AIRLOOP F6 S1 SUPPLY FAN | 0.188980 |
AIRLOOP F6 S2 SUPPLY FAN | 0.189977 |
AIRLOOP F7 SW SUPPLY FAN | 0.277156 |
AIRLOOP F7 NW SUPPLY FAN | 0.250708 |
AIRLOOP F7 SE SUPPLY FAN | 0.253855 |
AIRLOOP F7 NE SUPPLY FAN | 0.250010 |
AIRLOOP F7 N1 SUPPLY FAN | 0.147187 |
AIRLOOP F7 N2 SUPPLY FAN | 0.147172 |
AIRLOOP F7 S1 SUPPLY FAN | 0.188002 |
AIRLOOP F7 S2 SUPPLY FAN | 0.188997 |
AIRLOOP F8 SW SUPPLY FAN | 0.277195 |
AIRLOOP F8 NW SUPPLY FAN | 0.259051 |
AIRLOOP F8 SE SUPPLY FAN | 0.257049 |
AIRLOOP F8 NE SUPPLY FAN | 0.258295 |
AIRLOOP F8 N1 SUPPLY FAN | 0.152742 |
AIRLOOP F8 N2 SUPPLY FAN | 0.152725 |
AIRLOOP F8 S1 SUPPLY FAN | 0.188114 |
AIRLOOP F8 S2 SUPPLY FAN | 0.189112 |
AIRLOOP F9 SW SUPPLY FAN | 0.284478 |
AIRLOOP F9 NW SUPPLY FAN | 0.274327 |
AIRLOOP F9 SE SUPPLY FAN | 0.272366 |
AIRLOOP F9 NE SUPPLY FAN | 0.273511 |
AIRLOOP F9 N1 SUPPLY FAN | 0.164906 |
AIRLOOP F9 N2 SUPPLY FAN | 0.164888 |
AIRLOOP F9 S1 SUPPLY FAN | 0.192437 |
AIRLOOP F9 S2 SUPPLY FAN | 0.193499 |
AIRLOOP T SW SUPPLY FAN | 0.341153 |
AIRLOOP T NW SUPPLY FAN | 0.315821 |
AIRLOOP T SE SUPPLY FAN | 0.313486 |
AIRLOOP T NE SUPPLY FAN | 0.315021 |
AIRLOOP T N1 SUPPLY FAN | 0.207738 |
AIRLOOP T N2 SUPPLY FAN | 0.207719 |
AIRLOOP T S1 SUPPLY FAN | 0.252502 |
AIRLOOP T S2 SUPPLY FAN | 0.253492 |
Rated Air Flow Rate [m3/s] | Rated Heating Capacity [W] | Rated Water Flow Rate [m3/s] | |
HEAT PUMP HEATING MODE AIRLOOP G SW | 0.205722 | 3494.72 | 0.000076 |
HEAT PUMP HEATING MODE AIRLOOP G NW | 0.204303 | 3510.52 | 0.000077 |
HEAT PUMP HEATING MODE AIRLOOP OFFICE | 0.330758 | 5429.48 | 0.000119 |
HEAT PUMP HEATING MODE AIRLOOP G NE | 0.204414 | 3735.54 | 0.000082 |
HEAT PUMP HEATING MODE AIRLOOP G N1 | 0.140109 | 2734.62 | 0.000060 |
HEAT PUMP HEATING MODE AIRLOOP G N2 | 0.140111 | 2748.65 | 0.000060 |
HEAT PUMP HEATING MODE AIRLOOP G S1 | 0.139644 | 2553.60 | 0.000056 |
HEAT PUMP HEATING MODE AIRLOOP G S2 | 0.139944 | 2529.13 | 0.000055 |
HEAT PUMP HEATING MODE AIRLOOP F2 SW | 0.276460 | 4535.68 | 0.000099 |
HEAT PUMP HEATING MODE AIRLOOP F2 NW | 0.246600 | 4106.48 | 0.000090 |
HEAT PUMP HEATING MODE AIRLOOP F2 SE | 0.274256 | 4544.68 | 0.000099 |
HEAT PUMP HEATING MODE AIRLOOP F2 NE | 0.202350 | 3520.63 | 0.000077 |
HEAT PUMP HEATING MODE AIRLOOP F2 N1 | 0.127011 | 2311.88 | 0.000051 |
HEAT PUMP HEATING MODE AIRLOOP F2 N2 | 0.125501 | 2290.15 | 0.000050 |
HEAT PUMP HEATING MODE AIRLOOP F2 S1 | 0.183383 | 3179.81 | 0.000069 |
HEAT PUMP HEATING MODE AIRLOOP F2 S2 | 0.185963 | 3215.43 | 0.000070 |
HEAT PUMP HEATING MODE AIRLOOP F3 SW | 0.278474 | 4615.28 | 0.000101 |
HEAT PUMP HEATING MODE AIRLOOP F3 NW | 0.250036 | 4214.15 | 0.000092 |
HEAT PUMP HEATING MODE AIRLOOP F3 SE | 0.255812 | 4339.47 | 0.000095 |
HEAT PUMP HEATING MODE AIRLOOP F3 NE | 0.211032 | 3707.02 | 0.000081 |
HEAT PUMP HEATING MODE AIRLOOP F3 N1 | 0.131725 | 2404.18 | 0.000053 |
HEAT PUMP HEATING MODE AIRLOOP F3 N2 | 0.130226 | 2382.52 | 0.000052 |
HEAT PUMP HEATING MODE AIRLOOP F3 S1 | 0.188013 | 3273.79 | 0.000072 |
HEAT PUMP HEATING MODE AIRLOOP F3 S2 | 0.189236 | 3290.67 | 0.000072 |
HEAT PUMP HEATING MODE AIRLOOP F4 SW | 0.279135 | 4662.50 | 0.000102 |
HEAT PUMP HEATING MODE AIRLOOP F4 NW | 0.251045 | 4264.62 | 0.000093 |
HEAT PUMP HEATING MODE AIRLOOP F4 SE | 0.254953 | 4364.16 | 0.000095 |
HEAT PUMP HEATING MODE AIRLOOP F4 NE | 0.222077 | 3937.18 | 0.000086 |
HEAT PUMP HEATING MODE AIRLOOP F4 N1 | 0.133080 | 2441.97 | 0.000053 |
HEAT PUMP HEATING MODE AIRLOOP F4 N2 | 0.131586 | 2420.29 | 0.000053 |
HEAT PUMP HEATING MODE AIRLOOP F4 S1 | 0.189255 | 3313.17 | 0.000072 |
HEAT PUMP HEATING MODE AIRLOOP F4 S2 | 0.190282 | 3327.37 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP M SW | 0.281563 | 4727.00 | 0.000103 |
HEAT PUMP HEATING MODE AIRLOOP M NW | 0.253763 | 4331.99 | 0.000095 |
HEAT PUMP HEATING MODE AIRLOOP M SE | 0.257643 | 4431.34 | 0.000097 |
HEAT PUMP HEATING MODE AIRLOOP M NE | 0.230794 | 4113.64 | 0.000090 |
HEAT PUMP HEATING MODE AIRLOOP M N1 | 0.135898 | 2497.40 | 0.000055 |
HEAT PUMP HEATING MODE AIRLOOP M N2 | 0.134507 | 2477.54 | 0.000054 |
HEAT PUMP HEATING MODE AIRLOOP M S1 | 0.192026 | 3369.75 | 0.000074 |
HEAT PUMP HEATING MODE AIRLOOP M S2 | 0.193025 | 3383.58 | 0.000074 |
HEAT PUMP HEATING MODE AIRLOOP F6 SW | 0.278239 | 4724.80 | 0.000103 |
HEAT PUMP HEATING MODE AIRLOOP F6 NW | 0.250466 | 4310.11 | 0.000094 |
HEAT PUMP HEATING MODE AIRLOOP F6 SE | 0.254706 | 4414.82 | 0.000096 |
HEAT PUMP HEATING MODE AIRLOOP F6 NE | 0.241462 | 4357.64 | 0.000095 |
HEAT PUMP HEATING MODE AIRLOOP F6 N1 | 0.141680 | 2628.86 | 0.000057 |
HEAT PUMP HEATING MODE AIRLOOP F6 N2 | 0.141666 | 2634.80 | 0.000058 |
HEAT PUMP HEATING MODE AIRLOOP F6 S1 | 0.188980 | 3342.16 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F6 S2 | 0.189977 | 3355.99 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F7 SW | 0.277156 | 4731.90 | 0.000103 |
HEAT PUMP HEATING MODE AIRLOOP F7 NW | 0.250708 | 4338.99 | 0.000095 |
HEAT PUMP HEATING MODE AIRLOOP F7 SE | 0.253855 | 4424.29 | 0.000097 |
HEAT PUMP HEATING MODE AIRLOOP F7 NE | 0.250010 | 4542.98 | 0.000099 |
HEAT PUMP HEATING MODE AIRLOOP F7 N1 | 0.147187 | 2746.72 | 0.000060 |
HEAT PUMP HEATING MODE AIRLOOP F7 N2 | 0.147172 | 2752.95 | 0.000060 |
HEAT PUMP HEATING MODE AIRLOOP F7 S1 | 0.188002 | 3341.47 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F7 S2 | 0.188997 | 3355.33 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F8 SW | 0.277195 | 4752.25 | 0.000104 |
HEAT PUMP HEATING MODE AIRLOOP F8 NW | 0.259051 | 4502.70 | 0.000098 |
HEAT PUMP HEATING MODE AIRLOOP F8 SE | 0.257049 | 4498.51 | 0.000098 |
HEAT PUMP HEATING MODE AIRLOOP F8 NE | 0.258295 | 4717.07 | 0.000103 |
HEAT PUMP HEATING MODE AIRLOOP F8 N1 | 0.152742 | 2859.93 | 0.000062 |
HEAT PUMP HEATING MODE AIRLOOP F8 N2 | 0.152725 | 2866.33 | 0.000063 |
HEAT PUMP HEATING MODE AIRLOOP F8 S1 | 0.188114 | 3354.68 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F8 S2 | 0.189112 | 3368.59 | 0.000074 |
HEAT PUMP HEATING MODE AIRLOOP F9 SW | 0.284478 | 4854.53 | 0.000106 |
HEAT PUMP HEATING MODE AIRLOOP F9 NW | 0.274327 | 4762.06 | 0.000104 |
HEAT PUMP HEATING MODE AIRLOOP F9 SE | 0.272366 | 4768.51 | 0.000104 |
HEAT PUMP HEATING MODE AIRLOOP F9 NE | 0.273511 | 5004.16 | 0.000109 |
HEAT PUMP HEATING MODE AIRLOOP F9 N1 | 0.164906 | 3067.86 | 0.000067 |
HEAT PUMP HEATING MODE AIRLOOP F9 N2 | 0.164888 | 3074.38 | 0.000067 |
HEAT PUMP HEATING MODE AIRLOOP F9 S1 | 0.192437 | 3428.79 | 0.000075 |
HEAT PUMP HEATING MODE AIRLOOP F9 S2 | 0.193499 | 3441.45 | 0.000075 |
HEAT PUMP HEATING MODE AIRLOOP T SW | 0.341153 | 5702.34 | 0.000125 |
HEAT PUMP HEATING MODE AIRLOOP T NW | 0.315821 | 5362.38 | 0.000117 |
HEAT PUMP HEATING MODE AIRLOOP T SE | 0.313486 | 5332.29 | 0.000116 |
HEAT PUMP HEATING MODE AIRLOOP T NE | 0.315021 | 5603.29 | 0.000122 |
HEAT PUMP HEATING MODE AIRLOOP T N1 | 0.207738 | 3839.49 | 0.000084 |
HEAT PUMP HEATING MODE AIRLOOP T N2 | 0.207719 | 3845.33 | 0.000084 |
HEAT PUMP HEATING MODE AIRLOOP T S1 | 0.252502 | 4277.30 | 0.000093 |
HEAT PUMP HEATING MODE AIRLOOP T S2 | 0.253492 | 4290.87 | 0.000094 |
Nominal Capacity [W] | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW | 5790.18 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW | 5797.70 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE | 6934.29 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE | 5800.02 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 | 4447.31 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 | 4447.35 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 | 4437.51 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 | 4443.83 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW | 5756.77 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW | 5760.11 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE | 5771.78 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE | 5757.17 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 | 4049.99 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 | 4049.93 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 | 4049.80 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 | 4050.82 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW | 5934.99 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW | 5946.68 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE | 5930.08 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE | 5939.98 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 | 4101.16 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 | 4101.01 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 | 4090.68 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 | 4090.69 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW | 6165.08 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW | 6181.89 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE | 6155.84 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE | 6172.48 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 | 4230.13 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 | 4229.93 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 | 4214.22 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 | 4214.03 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW | 6348.25 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW | 6367.52 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE | 6336.76 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE | 6356.00 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 | 4330.10 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 | 4329.84 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 | 4311.63 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 | 4311.38 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW | 6570.94 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW | 6593.79 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE | 6557.70 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE | 6580.55 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 | 4480.77 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 | 4480.48 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 | 4458.67 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 | 4458.38 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW | 6750.30 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW | 6775.17 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE | 6735.63 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE | 6760.49 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 | 4596.67 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 | 4596.35 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 | 4572.53 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 | 4572.21 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW | 6924.59 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW | 6950.81 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE | 6908.67 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE | 6934.89 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 | 4713.56 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 | 4713.21 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 | 4688.06 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 | 4687.71 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW | 7248.20 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW | 7272.28 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE | 7231.03 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE | 7255.12 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 | 4969.48 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 | 4969.10 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 | 4945.66 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 | 4945.28 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW | 8113.34 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW | 8145.63 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE | 8096.51 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE | 8128.80 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 | 5870.68 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 | 5870.29 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 | 5835.47 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 | 5835.08 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
SHWSYS1 | 0.000289 | 0.325214 |
SINGLE WATER PLANT LOOP | 0.006604 | 7.43 |
Design Water Flow Rate [m3/s] | |
CENTRAL BOILER | 0.006604 |
Use Side Design Flow Rate [m3/s] | |
SHWSYS1 WATER HEATER | 0.000289 |
Design Water Flow Rate [m3/s] | Fan Power at Design Air Flow Rate [W] | Design Air Flow Rate [m3/s] | U-Factor Times Area Value at Design Air Flow Rate [W/C] | |
CENTRAL TOWER | 0.006604 | 3187.96 | 8.83 | 9391.94 |
Rated Flow Rate [m3/s] | Rated Power Consumption [W] | |
SHWSYS1 PUMP | 0.000289 | 36.93 |
PLANT CIRC PUMP | 0.006604 | 2108.92 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW3 | |
G WWALL SWA | GWINDOW2 | |
G NWALL NWA | GWINDOW4 | |
G WWALL NWA | GWINDOW6 | |
G SWALL SEA | GWINDOW1 | |
G EWALL SEA | GWINDOW8 | |
G NWALL NEA | GWINDOW5 | |
G EWALL NEA | GWINDOW7 | |
G NWALL N1A | GWINDOW9 | |
G NWALL N2A | GWINDOW10 | |
G SWALL S1A | GWINDOW11 | |
G SWALL S2A | GWINDOW12 | |
G WWALL C | GWINDOW13 | |
G EWALL C | ENTRANCE DOOR | |
F2 WWALL SWA | F2WINDOW2 | |
F2 SWALL SWA | F2WINDOW3 | |
F2 NWALL NWA | F2WINDOW4 | |
F2 WWALL NWA | F2WINDOW6 | |
F2 EWALL SEA | F2WINDOW8 | |
F2 SWALL SEA | F2WINDOW1 | |
F2 NWALL NEA | F2WINDOW5 | |
F2 EWALL NEA | F2WINDOW7 | |
F2 NWALL N1A | F2WINDOW9 | |
F2 NWALL N2A | F2WINDOW10 | |
F2 SWALL S1A | F2WINDOW11 | |
F2 SWALL S2A | F2WINDOW12 | |
F2 WWALL C | F2WINDOW13 | |
F2 EWALL C | F2WINDOW14 | |
F3 WWALL SWA | F3WINDOW2 | |
F3 SWALL SWA | F3WINDOW3 | |
F3 NWALL NWA | F3WINDOW4 | |
F3 WWALL NWA | F3WINDOW6 | |
F3 EWALL SEA | F3WINDOW8 | |
F3 SWALL SEA | F3WINDOW1 | |
F3 NWALL NEA | F3WINDOW5 | |
F3 EWALL NEA | F3WINDOW7 | |
F3 NWALL N1A | F3WINDOW9 | |
F3 NWALL N2A | F3WINDOW10 | |
F3 SWALL S1A | F3WINDOW11 | |
F3 SWALL S2A | F3WINDOW12 | |
F3 WWALL C | F3WINDOW13 | |
F3 EWALL C | F3WINDOW14 | |
F4 WWALL SWA | F4WINDOW2 | |
F4 SWALL SWA | F4WINDOW3 | |
F4 NWALL NWA | F4WINDOW4 | |
F4 WWALL NWA | F4WINDOW6 | |
F4 EWALL SEA | F4WINDOW8 | |
F4 SWALL SEA | F4WINDOW1 | |
F4 NWALL NEA | F4WINDOW5 | |
F4 EWALL NEA | F4WINDOW7 | |
F4 NWALL N1A | F4WINDOW9 | |
F4 NWALL N2A | F4WINDOW10 | |
F4 SWALL S1A | F4WINDOW11 | |
F4 SWALL S2A | F4WINDOW12 | |
F4 WWALL C | F4WINDOW13 | |
F4 EWALL C | F4WINDOW14 | |
M WWALL SWA | MWINDOW2 | |
M SWALL SWA | MWINDOW3 | |
M NWALL NWA | MWINDOW4 | |
M WWALL NWA | MWINDOW6 | |
M EWALL SEA | MWINDOW8 | |
M SWALL SEA | MWINDOW1 | |
M NWALL NEA | MWINDOW5 | |
M EWALL NEA | MWINDOW7 | |
M NWALL N1A | MWINDOW9 | |
M NWALL N2A | MWINDOW10 | |
M SWALL S1A | MWINDOW11 | |
M SWALL S2A | MWINDOW12 | |
M WWALL C | MWINDOW13 | |
M EWALL C | MWINDOW14 | |
F6 WWALL SWA | F6WINDOW2 | |
F6 SWALL SWA | F6WINDOW3 | |
F6 NWALL NWA | F6WINDOW4 | |
F6 WWALL NWA | F6WINDOW6 | |
F6 EWALL SEA | F6WINDOW8 | |
F6 SWALL SEA | F6WINDOW1 | |
F6 NWALL NEA | F6WINDOW5 | |
F6 EWALL NEA | F6WINDOW7 | |
F6 NWALL N1A | F6WINDOW9 | |
F6 NWALL N2A | F6WINDOW10 | |
F6 SWALL S1A | F6WINDOW11 | |
F6 SWALL S2A | F6WINDOW12 | |
F6 WWALL C | F6WINDOW13 | |
F6 EWALL C | F6WINDOW14 | |
F7 WWALL SWA | F7WINDOW2 | |
F7 SWALL SWA | F7WINDOW3 | |
F7 NWALL NWA | F7WINDOW4 | |
F7 WWALL NWA | F7WINDOW6 | |
F7 EWALL SEA | F7WINDOW8 | |
F7 SWALL SEA | F7WINDOW1 | |
F7 NWALL NEA | F7WINDOW5 | |
F7 EWALL NEA | F7WINDOW7 | |
F7 NWALL N1A | F7WINDOW9 | |
F7 NWALL N2A | F7WINDOW10 | |
F7 SWALL S1A | F7WINDOW11 | |
F7 SWALL S2A | F7WINDOW12 | |
F7 WWALL C | F7WINDOW13 | |
F7 EWALL C | F7WINDOW14 | |
F8 WWALL SWA | F8WINDOW2 | |
F8 SWALL SWA | F8WINDOW3 | |
F8 NWALL NWA | F8WINDOW4 | |
F8 WWALL NWA | F8WINDOW6 | |
F8 EWALL SEA | F8WINDOW8 | |
F8 SWALL SEA | F8WINDOW1 | |
F8 NWALL NEA | F8WINDOW5 | |
F8 EWALL NEA | F8WINDOW7 | |
F8 NWALL N1A | F8WINDOW9 | |
F8 NWALL N2A | F8WINDOW10 | |
F8 SWALL S1A | F8WINDOW11 | |
F8 SWALL S2A | F8WINDOW12 | |
F8 WWALL C | F8WINDOW13 | |
F8 EWALL C | F8WINDOW14 | |
F9 WWALL SWA | F9WINDOW2 | |
F9 SWALL SWA | F9WINDOW3 | |
F9 NWALL NWA | F9WINDOW4 | |
F9 WWALL NWA | F9WINDOW6 | |
F9 EWALL SEA | F9WINDOW8 | |
F9 SWALL SEA | F9WINDOW1 | |
F9 NWALL NEA | F9WINDOW5 | |
F9 EWALL NEA | F9WINDOW7 | |
F9 NWALL N1A | F9WINDOW9 | |
F9 NWALL N2A | F9WINDOW10 | |
F9 SWALL S1A | F9WINDOW11 | |
F9 SWALL S2A | F9WINDOW12 | |
F9 WWALL C | F9WINDOW13 | |
F9 EWALL C | F9WINDOW14 | |
T WWALL SWA | TWINDOW2 | |
T SWALL SWA | TWINDOW3 | |
T NWALL NWA | TWINDOW4 | |
T WWALL NWA | TWINDOW6 | |
T EWALL SEA | TWINDOW8 | |
T SWALL SEA | TWINDOW1 | |
T NWALL NEA | TWINDOW5 | |
T EWALL NEA | TWINDOW7 | |
T NWALL N1A | TWINDOW9 | |
T NWALL N2A | TWINDOW10 | |
T SWALL S1A | TWINDOW11 | |
T SWALL S2A | TWINDOW12 | |
T WWALL C | TWINDOW13 | |
T EWALL C | TWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.73 | -8.2 |
March | 21.81 | -2.6 |
April | 22.11 | 4.03 |
May | 22.89 | 12.37 |
June | 23.76 | 16.19 |
July | 23.97 | 17.83 |
August | 23.93 | 17.50 |
September | 23.42 | 12.89 |
October | 22.07 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.57 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 23.97 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.71 | -2.6 |
April | 21.82 | 4.03 |
May | 22.66 | 12.37 |
June | 23.71 | 16.19 |
July | 23.93 | 17.83 |
August | 23.81 | 17.50 |
September | 23.01 | 12.89 |
October | 21.79 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.44 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 23.93 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -13.0 |
February | 21.80 | -8.2 |
March | 21.98 | -2.6 |
April | 22.40 | 4.03 |
May | 23.33 | 12.37 |
June | 24.05 | 16.19 |
July | 24.21 | 17.83 |
August | 24.31 | 17.50 |
September | 23.78 | 12.89 |
October | 22.37 | 6.03 |
November | 21.77 | -4.5 |
December | 21.71 | -11.1 |
Annual Sum or Average | 22.79 | 4.02 |
Minimum of Months | 21.71 | -13.0 |
Maximum of Months | 24.31 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.70 | -2.6 |
April | 21.79 | 4.03 |
May | 22.61 | 12.37 |
June | 23.76 | 16.19 |
July | 23.93 | 17.83 |
August | 23.80 | 17.50 |
September | 22.99 | 12.89 |
October | 21.79 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.44 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 23.93 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.70 | -2.6 |
April | 21.73 | 4.03 |
May | 22.42 | 12.37 |
June | 23.64 | 16.19 |
July | 23.87 | 17.83 |
August | 23.71 | 17.50 |
September | 22.96 | 12.89 |
October | 21.78 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.39 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 23.87 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.70 | -2.6 |
April | 21.73 | 4.03 |
May | 22.41 | 12.37 |
June | 23.64 | 16.19 |
July | 23.87 | 17.83 |
August | 23.70 | 17.50 |
September | 22.96 | 12.89 |
October | 21.77 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.39 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 23.87 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.73 | -8.2 |
March | 21.80 | -2.6 |
April | 22.03 | 4.03 |
May | 22.72 | 12.37 |
June | 23.75 | 16.19 |
July | 23.95 | 17.83 |
August | 23.91 | 17.50 |
September | 23.56 | 12.89 |
October | 22.13 | 6.03 |
November | 21.71 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.56 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 23.95 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.73 | -8.2 |
March | 21.82 | -2.6 |
April | 22.06 | 4.03 |
May | 22.76 | 12.37 |
June | 23.79 | 16.19 |
July | 23.97 | 17.83 |
August | 23.94 | 17.50 |
September | 23.61 | 12.89 |
October | 22.15 | 6.03 |
November | 21.71 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.58 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 23.97 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 11.49 | -13.0 |
February | 13.15 | -8.2 |
March | 14.90 | -2.6 |
April | 17.31 | 4.03 |
May | 20.48 | 12.37 |
June | 22.67 | 16.19 |
July | 23.43 | 17.83 |
August | 23.14 | 17.50 |
September | 21.34 | 12.89 |
October | 17.80 | 6.03 |
November | 14.18 | -4.5 |
December | 12.01 | -11.1 |
Annual Sum or Average | 17.68 | 4.02 |
Minimum of Months | 11.49 | -13.0 |
Maximum of Months | 23.43 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F2 SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.77 | -8.2 |
March | 21.90 | -2.6 |
April | 22.46 | 4.03 |
May | 23.67 | 12.37 |
June | 24.11 | 16.19 |
July | 24.22 | 17.83 |
August | 24.16 | 17.50 |
September | 23.77 | 12.89 |
October | 22.34 | 6.03 |
November | 21.71 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.80 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.22 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F2 NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.73 | -2.6 |
April | 21.96 | 4.03 |
May | 23.29 | 12.37 |
June | 24.04 | 16.19 |
July | 24.16 | 17.83 |
August | 24.04 | 17.50 |
September | 23.25 | 12.89 |
October | 21.88 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.60 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.16 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F2 SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.77 | -8.2 |
March | 21.92 | -2.6 |
April | 22.60 | 4.03 |
May | 23.77 | 12.37 |
June | 24.21 | 16.19 |
July | 24.26 | 17.83 |
August | 24.21 | 17.50 |
September | 23.87 | 12.89 |
October | 22.43 | 6.03 |
November | 21.71 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.85 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.26 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F2 NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.71 | -2.6 |
April | 21.90 | 4.03 |
May | 23.18 | 12.37 |
June | 24.05 | 16.19 |
July | 24.12 | 17.83 |
August | 23.99 | 17.50 |
September | 23.12 | 12.89 |
October | 21.85 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.57 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.12 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F2 N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.71 | -2.6 |
April | 21.81 | 4.03 |
May | 23.03 | 12.37 |
June | 23.99 | 16.19 |
July | 24.11 | 17.83 |
August | 23.92 | 17.50 |
September | 23.13 | 12.89 |
October | 21.85 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.53 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.11 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F2 N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.71 | -2.6 |
April | 21.81 | 4.03 |
May | 23.01 | 12.37 |
June | 23.99 | 16.19 |
July | 24.10 | 17.83 |
August | 23.91 | 17.50 |
September | 23.11 | 12.89 |
October | 21.85 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.53 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.10 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F2 S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.80 | -8.2 |
March | 21.93 | -2.6 |
April | 22.49 | 4.03 |
May | 23.63 | 12.37 |
June | 24.13 | 16.19 |
July | 24.20 | 17.83 |
August | 24.13 | 17.50 |
September | 23.91 | 12.89 |
October | 22.51 | 6.03 |
November | 21.72 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.83 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.20 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F2 S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.80 | -8.2 |
March | 21.94 | -2.6 |
April | 22.51 | 4.03 |
May | 23.65 | 12.37 |
June | 24.15 | 16.19 |
July | 24.21 | 17.83 |
August | 24.14 | 17.50 |
September | 23.93 | 12.89 |
October | 22.52 | 6.03 |
November | 21.73 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.84 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.21 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F2 CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.05 | -13.0 |
February | 20.69 | -8.2 |
March | 21.32 | -2.6 |
April | 22.57 | 4.03 |
May | 24.40 | 12.37 |
June | 25.47 | 16.19 |
July | 25.75 | 17.83 |
August | 25.54 | 17.50 |
September | 24.58 | 12.89 |
October | 22.37 | 6.03 |
November | 20.84 | -4.5 |
December | 20.13 | -11.1 |
Annual Sum or Average | 22.82 | 4.02 |
Minimum of Months | 20.05 | -13.0 |
Maximum of Months | 25.75 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F3 SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.77 | -8.2 |
March | 21.90 | -2.6 |
April | 22.51 | 4.03 |
May | 23.77 | 12.37 |
June | 24.15 | 16.19 |
July | 24.23 | 17.83 |
August | 24.15 | 17.50 |
September | 23.76 | 12.89 |
October | 22.35 | 6.03 |
November | 21.71 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.81 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.23 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F3 NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.73 | -2.6 |
April | 21.98 | 4.03 |
May | 23.40 | 12.37 |
June | 24.08 | 16.19 |
July | 24.18 | 17.83 |
August | 24.04 | 17.50 |
September | 23.23 | 12.89 |
October | 21.89 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.62 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.18 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F3 SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.76 | -8.2 |
March | 21.89 | -2.6 |
April | 22.54 | 4.03 |
May | 23.77 | 12.37 |
June | 24.19 | 16.19 |
July | 24.22 | 17.83 |
August | 24.16 | 17.50 |
September | 23.75 | 12.89 |
October | 22.35 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.82 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.22 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F3 NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.72 | -2.6 |
April | 21.92 | 4.03 |
May | 23.29 | 12.37 |
June | 24.09 | 16.19 |
July | 24.14 | 17.83 |
August | 24.00 | 17.50 |
September | 23.11 | 12.89 |
October | 21.86 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.58 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.14 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F3 N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.71 | -2.6 |
April | 21.84 | 4.03 |
May | 23.19 | 12.37 |
June | 24.08 | 16.19 |
July | 24.14 | 17.83 |
August | 23.94 | 17.50 |
September | 23.14 | 12.89 |
October | 21.88 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.57 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.14 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F3 N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.71 | -2.6 |
April | 21.84 | 4.03 |
May | 23.18 | 12.37 |
June | 24.08 | 16.19 |
July | 24.14 | 17.83 |
August | 23.94 | 17.50 |
September | 23.12 | 12.89 |
October | 21.88 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.56 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.14 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F3 S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.82 | -8.2 |
March | 21.95 | -2.6 |
April | 22.61 | 4.03 |
May | 23.82 | 12.37 |
June | 24.19 | 16.19 |
July | 24.23 | 17.83 |
August | 24.13 | 17.50 |
September | 23.93 | 12.89 |
October | 22.58 | 6.03 |
November | 21.72 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.87 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.23 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F3 S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.82 | -8.2 |
March | 21.95 | -2.6 |
April | 22.62 | 4.03 |
May | 23.83 | 12.37 |
June | 24.20 | 16.19 |
July | 24.23 | 17.83 |
August | 24.13 | 17.50 |
September | 23.94 | 12.89 |
October | 22.59 | 6.03 |
November | 21.72 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.88 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.23 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F3 CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.72 | -13.0 |
February | 21.32 | -8.2 |
March | 21.86 | -2.6 |
April | 23.07 | 4.03 |
May | 24.90 | 12.37 |
June | 25.77 | 16.19 |
July | 25.96 | 17.83 |
August | 25.74 | 17.50 |
September | 24.81 | 12.89 |
October | 22.77 | 6.03 |
November | 21.37 | -4.5 |
December | 20.77 | -11.1 |
Annual Sum or Average | 23.27 | 4.02 |
Minimum of Months | 20.72 | -13.0 |
Maximum of Months | 25.96 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F4 SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.77 | -8.2 |
March | 21.89 | -2.6 |
April | 22.47 | 4.03 |
May | 23.75 | 12.37 |
June | 24.14 | 16.19 |
July | 24.23 | 17.83 |
August | 24.18 | 17.50 |
September | 23.74 | 12.89 |
October | 22.33 | 6.03 |
November | 21.71 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.81 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.23 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F4 NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.74 | -2.6 |
April | 21.97 | 4.03 |
May | 23.39 | 12.37 |
June | 24.07 | 16.19 |
July | 24.17 | 17.83 |
August | 24.07 | 17.50 |
September | 23.20 | 12.89 |
October | 21.88 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.61 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.17 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F4 SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.75 | -8.2 |
March | 21.88 | -2.6 |
April | 22.48 | 4.03 |
May | 23.73 | 12.37 |
June | 24.17 | 16.19 |
July | 24.21 | 17.83 |
August | 24.17 | 17.50 |
September | 23.70 | 12.89 |
October | 22.31 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.80 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.21 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F4 NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.72 | -2.6 |
April | 21.92 | 4.03 |
May | 23.30 | 12.37 |
June | 24.09 | 16.19 |
July | 24.14 | 17.83 |
August | 24.04 | 17.50 |
September | 23.09 | 12.89 |
October | 21.86 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.59 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.14 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F4 N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.72 | -2.6 |
April | 21.85 | 4.03 |
May | 23.22 | 12.37 |
June | 24.09 | 16.19 |
July | 24.15 | 17.83 |
August | 23.98 | 17.50 |
September | 23.13 | 12.89 |
October | 21.88 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.57 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.15 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F4 N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.72 | -2.6 |
April | 21.85 | 4.03 |
May | 23.21 | 12.37 |
June | 24.09 | 16.19 |
July | 24.15 | 17.83 |
August | 23.98 | 17.50 |
September | 23.11 | 12.89 |
October | 21.88 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.57 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.15 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F4 S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.82 | -8.2 |
March | 21.95 | -2.6 |
April | 22.60 | 4.03 |
May | 23.84 | 12.37 |
June | 24.20 | 16.19 |
July | 24.23 | 17.83 |
August | 24.17 | 17.50 |
September | 23.93 | 12.89 |
October | 22.58 | 6.03 |
November | 21.72 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.88 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.23 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F4 S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.82 | -8.2 |
March | 21.95 | -2.6 |
April | 22.61 | 4.03 |
May | 23.84 | 12.37 |
June | 24.20 | 16.19 |
July | 24.23 | 17.83 |
August | 24.17 | 17.50 |
September | 23.93 | 12.89 |
October | 22.58 | 6.03 |
November | 21.72 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.88 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.23 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F4 CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.85 | -13.0 |
February | 21.45 | -8.2 |
March | 21.99 | -2.6 |
April | 23.20 | 4.03 |
May | 25.05 | 12.37 |
June | 25.88 | 16.19 |
July | 26.06 | 17.83 |
August | 25.85 | 17.50 |
September | 24.88 | 12.89 |
October | 22.88 | 6.03 |
November | 21.50 | -4.5 |
December | 20.90 | -11.1 |
Annual Sum or Average | 23.38 | 4.02 |
Minimum of Months | 20.85 | -13.0 |
Maximum of Months | 26.06 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.76 | -8.2 |
March | 21.88 | -2.6 |
April | 22.44 | 4.03 |
May | 23.71 | 12.37 |
June | 24.12 | 16.19 |
July | 24.22 | 17.83 |
August | 24.17 | 17.50 |
September | 23.70 | 12.89 |
October | 22.31 | 6.03 |
November | 21.71 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.79 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.22 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.74 | -2.6 |
April | 21.96 | 4.03 |
May | 23.36 | 12.37 |
June | 24.05 | 16.19 |
July | 24.16 | 17.83 |
August | 24.06 | 17.50 |
September | 23.15 | 12.89 |
October | 21.88 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.60 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.16 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.75 | -8.2 |
March | 21.87 | -2.6 |
April | 22.44 | 4.03 |
May | 23.69 | 12.37 |
June | 24.15 | 16.19 |
July | 24.20 | 17.83 |
August | 24.16 | 17.50 |
September | 23.66 | 12.89 |
October | 22.29 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.78 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.20 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.72 | -2.6 |
April | 21.92 | 4.03 |
May | 23.29 | 12.37 |
June | 24.08 | 16.19 |
July | 24.14 | 17.83 |
August | 24.03 | 17.50 |
September | 23.06 | 12.89 |
October | 21.86 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.58 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.14 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.72 | -2.6 |
April | 21.85 | 4.03 |
May | 23.21 | 12.37 |
June | 24.08 | 16.19 |
July | 24.15 | 17.83 |
August | 23.98 | 17.50 |
September | 23.10 | 12.89 |
October | 21.88 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.57 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.15 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.72 | -2.6 |
April | 21.85 | 4.03 |
May | 23.20 | 12.37 |
June | 24.09 | 16.19 |
July | 24.14 | 17.83 |
August | 23.97 | 17.50 |
September | 23.09 | 12.89 |
October | 21.88 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.57 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.14 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.81 | -8.2 |
March | 21.94 | -2.6 |
April | 22.58 | 4.03 |
May | 23.82 | 12.37 |
June | 24.19 | 16.19 |
July | 24.23 | 17.83 |
August | 24.15 | 17.50 |
September | 23.90 | 12.89 |
October | 22.56 | 6.03 |
November | 21.72 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.86 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.23 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.81 | -8.2 |
March | 21.94 | -2.6 |
April | 22.58 | 4.03 |
May | 23.82 | 12.37 |
June | 24.19 | 16.19 |
July | 24.23 | 17.83 |
August | 24.15 | 17.50 |
September | 23.90 | 12.89 |
October | 22.56 | 6.03 |
November | 21.72 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.86 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.23 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.36 | -13.0 |
February | 21.98 | -8.2 |
March | 22.52 | -2.6 |
April | 23.74 | 4.03 |
May | 25.57 | 12.37 |
June | 26.41 | 16.19 |
July | 26.59 | 17.83 |
August | 26.39 | 17.50 |
September | 25.39 | 12.89 |
October | 23.43 | 6.03 |
November | 22.06 | -4.5 |
December | 21.41 | -11.1 |
Annual Sum or Average | 23.91 | 4.02 |
Minimum of Months | 21.36 | -13.0 |
Maximum of Months | 26.59 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F6 SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.75 | -8.2 |
March | 21.86 | -2.6 |
April | 22.37 | 4.03 |
May | 23.62 | 12.37 |
June | 24.06 | 16.19 |
July | 24.17 | 17.83 |
August | 24.13 | 17.50 |
September | 23.60 | 12.89 |
October | 22.24 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.75 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.17 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F6 NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.73 | -2.6 |
April | 21.93 | 4.03 |
May | 23.27 | 12.37 |
June | 23.98 | 16.19 |
July | 24.11 | 17.83 |
August | 24.01 | 17.50 |
September | 23.01 | 12.89 |
October | 21.85 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.56 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.11 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F6 SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.74 | -8.2 |
March | 21.85 | -2.6 |
April | 22.36 | 4.03 |
May | 23.58 | 12.37 |
June | 24.09 | 16.19 |
July | 24.15 | 17.83 |
August | 24.12 | 17.50 |
September | 23.55 | 12.89 |
October | 22.22 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.74 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.15 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F6 NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.72 | -2.6 |
April | 21.89 | 4.03 |
May | 23.21 | 12.37 |
June | 24.02 | 16.19 |
July | 24.10 | 17.83 |
August | 23.99 | 17.50 |
September | 22.95 | 12.89 |
October | 21.84 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.55 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.10 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F6 N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.72 | -2.6 |
April | 21.83 | 4.03 |
May | 23.13 | 12.37 |
June | 24.01 | 16.19 |
July | 24.10 | 17.83 |
August | 23.92 | 17.50 |
September | 22.97 | 12.89 |
October | 21.86 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.53 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.10 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F6 N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.72 | -2.6 |
April | 21.83 | 4.03 |
May | 23.12 | 12.37 |
June | 24.02 | 16.19 |
July | 24.10 | 17.83 |
August | 23.92 | 17.50 |
September | 22.96 | 12.89 |
October | 21.86 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.53 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.10 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F6 S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.80 | -8.2 |
March | 21.91 | -2.6 |
April | 22.48 | 4.03 |
May | 23.71 | 12.37 |
June | 24.14 | 16.19 |
July | 24.19 | 17.83 |
August | 24.12 | 17.50 |
September | 23.80 | 12.89 |
October | 22.47 | 6.03 |
November | 21.71 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.82 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.19 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F6 S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.80 | -8.2 |
March | 21.91 | -2.6 |
April | 22.48 | 4.03 |
May | 23.71 | 12.37 |
June | 24.14 | 16.19 |
July | 24.19 | 17.83 |
August | 24.12 | 17.50 |
September | 23.79 | 12.89 |
October | 22.47 | 6.03 |
November | 21.71 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.82 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.19 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F6 CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.76 | -13.0 |
February | 21.36 | -8.2 |
March | 21.90 | -2.6 |
April | 23.09 | 4.03 |
May | 24.93 | 12.37 |
June | 25.79 | 16.19 |
July | 25.99 | 17.83 |
August | 25.78 | 17.50 |
September | 24.72 | 12.89 |
October | 22.77 | 6.03 |
November | 21.43 | -4.5 |
December | 20.81 | -11.1 |
Annual Sum or Average | 23.29 | 4.02 |
Minimum of Months | 20.76 | -13.0 |
Maximum of Months | 25.99 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F7 SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.74 | -8.2 |
March | 21.85 | -2.6 |
April | 22.32 | 4.03 |
May | 23.54 | 12.37 |
June | 24.00 | 16.19 |
July | 24.14 | 17.83 |
August | 24.10 | 17.50 |
September | 23.51 | 12.89 |
October | 22.20 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.72 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.14 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F7 NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.73 | -2.6 |
April | 21.90 | 4.03 |
May | 23.21 | 12.37 |
June | 23.91 | 16.19 |
July | 24.07 | 17.83 |
August | 23.97 | 17.50 |
September | 22.91 | 12.89 |
October | 21.83 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.53 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.07 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F7 SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.74 | -8.2 |
March | 21.84 | -2.6 |
April | 22.30 | 4.03 |
May | 23.50 | 12.37 |
June | 24.03 | 16.19 |
July | 24.11 | 17.83 |
August | 24.09 | 17.50 |
September | 23.47 | 12.89 |
October | 22.18 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.70 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.11 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F7 NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.72 | -2.6 |
April | 21.87 | 4.03 |
May | 23.16 | 12.37 |
June | 23.97 | 16.19 |
July | 24.07 | 17.83 |
August | 23.95 | 17.50 |
September | 22.86 | 12.89 |
October | 21.83 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.52 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.07 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F7 N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.72 | -2.6 |
April | 21.82 | 4.03 |
May | 23.08 | 12.37 |
June | 23.95 | 16.19 |
July | 24.06 | 17.83 |
August | 23.88 | 17.50 |
September | 22.88 | 12.89 |
October | 21.84 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.51 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.06 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F7 N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.72 | -2.6 |
April | 21.81 | 4.03 |
May | 23.07 | 12.37 |
June | 23.96 | 16.19 |
July | 24.06 | 17.83 |
August | 23.88 | 17.50 |
September | 22.87 | 12.89 |
October | 21.84 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.51 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.06 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F7 S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.79 | -8.2 |
March | 21.90 | -2.6 |
April | 22.41 | 4.03 |
May | 23.62 | 12.37 |
June | 24.09 | 16.19 |
July | 24.16 | 17.83 |
August | 24.10 | 17.50 |
September | 23.72 | 12.89 |
October | 22.41 | 6.03 |
November | 21.71 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.78 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.16 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F7 S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.79 | -8.2 |
March | 21.90 | -2.6 |
April | 22.41 | 4.03 |
May | 23.62 | 12.37 |
June | 24.09 | 16.19 |
July | 24.16 | 17.83 |
August | 24.09 | 17.50 |
September | 23.71 | 12.89 |
October | 22.41 | 6.03 |
November | 21.71 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.78 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.16 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F7 CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.61 | -13.0 |
February | 21.21 | -8.2 |
March | 21.74 | -2.6 |
April | 22.93 | 4.03 |
May | 24.76 | 12.37 |
June | 25.64 | 16.19 |
July | 25.87 | 17.83 |
August | 25.66 | 17.50 |
September | 24.53 | 12.89 |
October | 22.61 | 6.03 |
November | 21.29 | -4.5 |
December | 20.66 | -11.1 |
Annual Sum or Average | 23.14 | 4.02 |
Minimum of Months | 20.61 | -13.0 |
Maximum of Months | 25.87 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F8 SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.74 | -8.2 |
March | 21.84 | -2.6 |
April | 22.28 | 4.03 |
May | 23.48 | 12.37 |
June | 23.96 | 16.19 |
July | 24.11 | 17.83 |
August | 24.08 | 17.50 |
September | 23.44 | 12.89 |
October | 22.16 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.69 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.11 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F8 NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.73 | -2.6 |
April | 21.89 | 4.03 |
May | 23.17 | 12.37 |
June | 23.87 | 16.19 |
July | 24.05 | 17.83 |
August | 23.94 | 17.50 |
September | 22.84 | 12.89 |
October | 21.82 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.51 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.05 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F8 SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.73 | -8.2 |
March | 21.83 | -2.6 |
April | 22.26 | 4.03 |
May | 23.43 | 12.37 |
June | 23.99 | 16.19 |
July | 24.08 | 17.83 |
August | 24.06 | 17.50 |
September | 23.40 | 12.89 |
October | 22.15 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.68 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.08 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F8 NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.72 | -2.6 |
April | 21.86 | 4.03 |
May | 23.12 | 12.37 |
June | 23.93 | 16.19 |
July | 24.04 | 17.83 |
August | 23.92 | 17.50 |
September | 22.79 | 12.89 |
October | 21.82 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.50 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.04 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F8 N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.71 | -2.6 |
April | 21.81 | 4.03 |
May | 23.04 | 12.37 |
June | 23.90 | 16.19 |
July | 24.03 | 17.83 |
August | 23.85 | 17.50 |
September | 22.80 | 12.89 |
October | 21.83 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.49 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.03 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F8 N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.71 | -2.6 |
April | 21.81 | 4.03 |
May | 23.03 | 12.37 |
June | 23.90 | 16.19 |
July | 24.03 | 17.83 |
August | 23.84 | 17.50 |
September | 22.79 | 12.89 |
October | 21.83 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.49 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.03 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F8 S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.78 | -8.2 |
March | 21.88 | -2.6 |
April | 22.36 | 4.03 |
May | 23.54 | 12.37 |
June | 24.04 | 16.19 |
July | 24.13 | 17.83 |
August | 24.07 | 17.50 |
September | 23.64 | 12.89 |
October | 22.36 | 6.03 |
November | 21.71 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.75 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.13 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F8 S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.78 | -8.2 |
March | 21.88 | -2.6 |
April | 22.36 | 4.03 |
May | 23.54 | 12.37 |
June | 24.04 | 16.19 |
July | 24.12 | 17.83 |
August | 24.07 | 17.50 |
September | 23.64 | 12.89 |
October | 22.36 | 6.03 |
November | 21.71 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.75 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.12 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F8 CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.51 | -13.0 |
February | 21.12 | -8.2 |
March | 21.66 | -2.6 |
April | 22.85 | 4.03 |
May | 24.68 | 12.37 |
June | 25.57 | 16.19 |
July | 25.82 | 17.83 |
August | 25.61 | 17.50 |
September | 24.42 | 12.89 |
October | 22.52 | 6.03 |
November | 21.20 | -4.5 |
December | 20.57 | -11.1 |
Annual Sum or Average | 23.05 | 4.02 |
Minimum of Months | 20.51 | -13.0 |
Maximum of Months | 25.82 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F9 SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.73 | -8.2 |
March | 21.84 | -2.6 |
April | 22.25 | 4.03 |
May | 23.42 | 12.37 |
June | 23.90 | 16.19 |
July | 24.06 | 17.83 |
August | 24.04 | 17.50 |
September | 23.35 | 12.89 |
October | 22.13 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.66 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.06 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F9 NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.73 | -2.6 |
April | 21.89 | 4.03 |
May | 23.14 | 12.37 |
June | 23.82 | 16.19 |
July | 24.01 | 17.83 |
August | 23.91 | 17.50 |
September | 22.77 | 12.89 |
October | 21.81 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.50 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.01 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F9 SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.73 | -8.2 |
March | 21.83 | -2.6 |
April | 22.24 | 4.03 |
May | 23.38 | 12.37 |
June | 23.94 | 16.19 |
July | 24.05 | 17.83 |
August | 24.03 | 17.50 |
September | 23.33 | 12.89 |
October | 22.12 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.65 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.05 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F9 NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.72 | -2.6 |
April | 21.86 | 4.03 |
May | 23.10 | 12.37 |
June | 23.88 | 16.19 |
July | 24.00 | 17.83 |
August | 23.89 | 17.50 |
September | 22.73 | 12.89 |
October | 21.81 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.49 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.00 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F9 N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.71 | -2.6 |
April | 21.81 | 4.03 |
May | 23.02 | 12.37 |
June | 23.84 | 16.19 |
July | 23.99 | 17.83 |
August | 23.82 | 17.50 |
September | 22.73 | 12.89 |
October | 21.82 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.47 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 23.99 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F9 N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.71 | -2.6 |
April | 21.81 | 4.03 |
May | 23.02 | 12.37 |
June | 23.85 | 16.19 |
July | 23.99 | 17.83 |
August | 23.81 | 17.50 |
September | 22.73 | 12.89 |
October | 21.82 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.47 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 23.99 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F9 S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.77 | -8.2 |
March | 21.87 | -2.6 |
April | 22.32 | 4.03 |
May | 23.47 | 12.37 |
June | 23.98 | 16.19 |
July | 24.09 | 17.83 |
August | 24.04 | 17.50 |
September | 23.54 | 12.89 |
October | 22.30 | 6.03 |
November | 21.71 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.71 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.09 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F9 S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.77 | -8.2 |
March | 21.87 | -2.6 |
April | 22.32 | 4.03 |
May | 23.47 | 12.37 |
June | 23.98 | 16.19 |
July | 24.08 | 17.83 |
August | 24.04 | 17.50 |
September | 23.54 | 12.89 |
October | 22.31 | 6.03 |
November | 21.71 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.71 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.08 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: F9 CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.30 | -13.0 |
February | 20.94 | -8.2 |
March | 21.51 | -2.6 |
April | 22.75 | 4.03 |
May | 24.62 | 12.37 |
June | 25.53 | 16.19 |
July | 25.80 | 17.83 |
August | 25.58 | 17.50 |
September | 24.31 | 12.89 |
October | 22.40 | 6.03 |
November | 21.04 | -4.5 |
December | 20.37 | -11.1 |
Annual Sum or Average | 22.94 | 4.02 |
Minimum of Months | 20.30 | -13.0 |
Maximum of Months | 25.80 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.76 | -8.2 |
March | 21.87 | -2.6 |
April | 22.30 | 4.03 |
May | 23.25 | 12.37 |
June | 23.71 | 16.19 |
July | 23.90 | 17.83 |
August | 23.86 | 17.50 |
September | 23.08 | 12.89 |
October | 22.11 | 6.03 |
November | 21.71 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.58 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 23.90 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.75 | -2.6 |
April | 21.98 | 4.03 |
May | 23.04 | 12.37 |
June | 23.65 | 16.19 |
July | 23.84 | 17.83 |
August | 23.72 | 17.50 |
September | 22.65 | 12.89 |
October | 21.83 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.44 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 23.84 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.75 | -8.2 |
March | 21.86 | -2.6 |
April | 22.28 | 4.03 |
May | 23.23 | 12.37 |
June | 23.74 | 16.19 |
July | 23.89 | 17.83 |
August | 23.83 | 17.50 |
September | 23.06 | 12.89 |
October | 22.10 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.58 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 23.89 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.74 | -2.6 |
April | 21.93 | 4.03 |
May | 23.03 | 12.37 |
June | 23.71 | 16.19 |
July | 23.85 | 17.83 |
August | 23.72 | 17.50 |
September | 22.63 | 12.89 |
October | 21.83 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.44 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 23.85 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.74 | -2.6 |
April | 21.89 | 4.03 |
May | 22.98 | 12.37 |
June | 23.69 | 16.19 |
July | 23.84 | 17.83 |
August | 23.69 | 17.50 |
September | 22.62 | 12.89 |
October | 21.83 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.43 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 23.84 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.74 | -2.6 |
April | 21.89 | 4.03 |
May | 22.98 | 12.37 |
June | 23.70 | 16.19 |
July | 23.84 | 17.83 |
August | 23.68 | 17.50 |
September | 22.62 | 12.89 |
October | 21.83 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.43 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 23.84 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.79 | -8.2 |
March | 21.90 | -2.6 |
April | 22.35 | 4.03 |
May | 23.32 | 12.37 |
June | 23.81 | 16.19 |
July | 23.95 | 17.83 |
August | 23.91 | 17.50 |
September | 23.27 | 12.89 |
October | 22.23 | 6.03 |
November | 21.72 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.64 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 23.95 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.79 | -8.2 |
March | 21.90 | -2.6 |
April | 22.35 | 4.03 |
May | 23.32 | 12.37 |
June | 23.81 | 16.19 |
July | 23.95 | 17.83 |
August | 23.91 | 17.50 |
September | 23.26 | 12.89 |
October | 22.23 | 6.03 |
November | 21.72 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.64 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 23.95 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.95 | -13.0 |
February | 20.74 | -8.2 |
March | 21.54 | -2.6 |
April | 23.04 | 4.03 |
May | 25.10 | 12.37 |
June | 26.06 | 16.19 |
July | 26.36 | 17.83 |
August | 26.12 | 17.50 |
September | 24.64 | 12.89 |
October | 22.57 | 6.03 |
November | 20.92 | -4.5 |
December | 20.05 | -11.1 |
Annual Sum or Average | 23.10 | 4.02 |
Minimum of Months | 19.95 | -13.0 |
Maximum of Months | 26.36 | 17.83 |
Report: COMPONENTS OF PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2015-09-09 19:00:30
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W] | |
January | 0.343948E+12 | 290808.573 | 11-JAN-11:00 | 9104.941 | 36356.634 | 20017.053 | 222001.392 | 0.000 | 0.000 | 2145.842 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
February | 0.269574E+12 | 190142.042 | 23-FEB-17:00 | 11327.174 | 57142.088 | 20017.053 | 87150.726 | 0.000 | 10364.000 | 2145.842 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
March | 0.268461E+12 | 146072.512 | 06-MAR-19:00 | 14401.373 | 51749.961 | 20017.053 | 45633.257 | 0.000 | 10364.000 | 2145.842 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
April | 0.214824E+12 | 120271.198 | 10-APR-19:00 | 14401.373 | 49889.926 | 20017.053 | 21811.700 | 0.000 | 10364.000 | 2145.842 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
May | 0.212752E+12 | 155697.498 | 18-MAY-17:00 | 13120.457 | 57042.023 | 20017.053 | 0.000 | 59359.969 | 0.000 | 2145.842 | 2024.145 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
June | 0.227305E+12 | 172990.141 | 25-JUN-17:15 | 13120.457 | 57042.023 | 20017.053 | 0.000 | 75722.153 | 0.000 | 2145.842 | 2954.801 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
July | 0.243127E+12 | 173883.274 | 16-JUL-17:30 | 13120.457 | 57042.023 | 20017.053 | 0.000 | 76407.772 | 0.000 | 2145.842 | 3162.117 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.230856E+12 | 167200.330 | 09-AUG-16:15 | 11327.174 | 57142.088 | 20017.053 | 0.000 | 71805.995 | 0.000 | 2145.842 | 2766.981 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.202126E+12 | 152024.478 | 17-SEP-16:15 | 11327.174 | 57042.023 | 20017.053 | 0.000 | 57202.419 | 0.000 | 2145.842 | 2302.324 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
October | 0.229802E+12 | 142096.456 | 25-OCT-17:15 | 13120.457 | 57042.023 | 20017.053 | 37419.269 | 0.000 | 10364.000 | 2145.842 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
November | 0.274484E+12 | 170470.699 | 28-NOV-07:15 | 9533.891 | 40866.781 | 20017.053 | 86476.222 | 0.000 | 10364.000 | 2145.842 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
December | 0.331277E+12 | 281726.794 | 19-DEC-02:00 | 6715.875 | 19509.987 | 20017.053 | 222302.079 | 0.000 | 10364.000 | 2145.842 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.304854E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||||
Minimum of Months | 0.202126E+12 | 120271.198 | 6715.875 | 19509.987 | 20017.053 | 0.000 | 0.000 | 0.000 | 2145.842 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.343948E+12 | 290808.573 | 14401.373 | 57142.088 | 20017.053 | 222302.079 | 76407.772 | 10364.000 | 2145.842 | 3162.117 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: COMPONENTS OF PEAK GAS DEMAND
For: Meter
Timestamp: 2015-09-09 19:00:30
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC [Invalid/Undefined] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT {AT MAX/MIN} [W] | WATERSYSTEMS:GAS {AT MAX/MIN} [W] | WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.660132E+12 | 415921.913 | 09-JAN-07:30 | 0.000 | 0.000 | 0.000 | 415921.913 | 86889.942 | 86889.942 | 329031.970 |
February | 0.473973E+12 | 396616.237 | 05-FEB-07:30 | 0.000 | 0.000 | 0.000 | 396616.237 | 87085.983 | 87085.983 | 309530.254 |
March | 0.397722E+12 | 351806.177 | 23-MAR-05:15 | 0.000 | 0.000 | 0.000 | 351806.177 | 70672.094 | 70672.094 | 281134.083 |
April | 0.196031E+12 | 180122.232 | 19-APR-06:00 | 0.000 | 0.000 | 0.000 | 180122.232 | 86745.692 | 86745.692 | 93376.540 |
May | 0.121744E+12 | 127880.830 | 09-MAY-06:30 | 0.000 | 0.000 | 0.000 | 127880.830 | 84998.244 | 84998.244 | 42882.586 |
June | 0.106894E+12 | 83378.723 | 01-JUN-06:00 | 0.000 | 0.000 | 0.000 | 83378.723 | 83378.723 | 83378.723 | 0.000 |
July | 0.105557E+12 | 81162.575 | 02-JUL-06:00 | 0.000 | 0.000 | 0.000 | 81162.575 | 81162.575 | 81162.575 | 0.000 |
August | 0.103555E+12 | 115847.079 | 17-AUG-17:00 | 0.000 | 0.000 | 0.000 | 115847.079 | 74481.804 | 74481.804 | 41365.275 |
September | 0.103201E+12 | 118222.106 | 28-SEP-07:00 | 0.000 | 0.000 | 0.000 | 118222.106 | 78477.152 | 78477.152 | 39744.954 |
October | 0.206746E+12 | 243874.140 | 25-OCT-11:45 | 0.000 | 0.000 | 0.000 | 243874.140 | 63612.810 | 63612.810 | 180261.331 |
November | 0.424172E+12 | 393520.219 | 28-NOV-07:30 | 0.000 | 0.000 | 0.000 | 393520.219 | 83615.719 | 83615.719 | 309904.500 |
December | 0.624515E+12 | 411351.482 | 24-DEC-07:15 | 0.000 | 0.000 | 0.000 | 411351.482 | 84766.879 | 84766.879 | 326584.602 |
Annual Sum or Average | 0.352424E+13 | 0.000 | 0.000 | 0.000 | ||||||
Minimum of Months | 0.103201E+12 | 81162.575 | 0.000 | 0.000 | 0.000 | 81162.575 | 63612.810 | 63612.810 | 0.000 | |
Maximum of Months | 0.660132E+12 | 415921.913 | 0.000 | 0.000 | 0.000 | 415921.913 | 87085.983 | 87085.983 | 329031.970 |