Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:59

Tabular Output Report in Format: HTML

Building: High-Rise Apartment

Environment: Duluth International Arpt MN USA TMY3 WMO#=727450

Simulation Timestamp: 2015-09-09 19:00:30


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 6572.78 838.74 931.00
Net Site Energy 6572.78 838.74 931.00
Total Source Energy 13474.99 1719.52 1908.67
Net Source Energy 13474.99 1719.52 1908.67


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 7836.48
Net Conditioned Building Area 7059.89
Unconditioned Building Area 776.58


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 567.85 2181.16 0.00 0.00 0.00 0.00
Cooling 144.53 0.00 0.00 0.00 0.00 0.00
Interior Lighting 296.56 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 162.58 0.00 0.00 0.00 0.00 0.00
Interior Equipment 1137.32 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 631.26 0.00 0.00 0.00 0.00 0.00
Pumps 65.89 0.00 0.00 0.00 0.00 0.00
Heat Rejection 6.37 0.00 0.00 0.00 0.00 452.49
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 1343.09 0.00 0.00 0.00 4778.51
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 3048.54 3524.24 0.00 0.00 0.00 5231.00
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating Boiler 0.00 2181.16 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
  Other 567.85 0.00 0.00 0.00 0.00 0.00
Cooling General 144.53 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 242.55 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 54.01 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 162.58 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 1137.32 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 631.26 0.00 0.00 0.00 0.00 0.00
Pumps General 65.89 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 6.37 0.00 0.00 0.00 0.00 452.49
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 1343.09 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 4778.51
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 65.03 0.00 0.00 0.00 0.00 0.00
HVAC 200.56 499.19 0.00 0.00 0.00 0.74
Other 161.10 0.00 0.00 0.00 0.00 0.00
Total 431.81 499.19 0.00 0.00 0.00 0.74


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 58.59 0.00 0.00 0.00 0.00 0.00
HVAC 180.68 449.72 0.00 0.00 0.00 0.67
Other 145.13 0.00 0.00 0.00 0.00 0.00
Total 389.02 449.72 0.00 0.00 0.00 0.67


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 3048.54 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 3048.54 100.00
     
Total On-Site and Utility Electric Sources 3048.54 100.00
Total Electricity End Uses 3048.54 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 5231.00 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 5231.00 100.00
Total Water End Uses 5231.00 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 109.00
Time Setpoint Not Met During Occupied Cooling 51.75
Time Not Comfortable Based on Simple ASHRAE 55-2004 4000.75


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |

COMPONENTS OF PEAK ELECTRICAL DEMAND

| Meter |

COMPONENTS OF PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:59
RunPeriod Duluth International Arpt MN USA TMY3 WMO#=727450
Weather File Duluth International Arpt MN USA TMY3 WMO#=727450
Latitude [deg] 46.83
Longitude [deg] -92.2
Elevation [m] 433.00
Time Zone -6.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3855.02 1411.96 515.55 1411.96 515.55
Window Opening Area [m2] 1150.39 423.59 152.73 423.59 150.48
Window-Wall Ratio [%] 29.84 30.00 29.62 30.00 29.19


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3752.84 1411.96 464.46 1411.96 464.46
Window Opening Area [m2] 1125.85 423.59 139.34 423.59 139.34
Window-Wall Ratio [%] 30.00 30.00 30.00 30.00 30.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
OFFICE 88.25 Yes Yes 268.96 1.00 58.52 17.56 29.5362 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 4.47 6.7128   0.0000
F2 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F3 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F4 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
M SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
M CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 13.4255   0.0000
F6 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F7 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F8 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F9 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
T SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   264.3872
Total 7836.48     23884.04   3855.02 1150.39 4.3335 39.48 8.6291
Conditioned Total 7059.89     21517.16   3752.84 1125.85 3.9979 35.57 6.6700
Unconditioned Total 776.58     2366.87   102.18 24.54 7.3840   26.4387
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 11-JAN-11:00 09-JAN-07:30 - - - 25-JUN-17:30
Heating 222001.39 329031.97 0.00 0.00 0.00 0.00
Cooling 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 9104.94 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 36356.63 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 20017.05 0.00 0.00 0.00 0.00 0.00
Pumps 2145.84 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 86889.94 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 290808.57 415921.91 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating Boiler 0.00 329031.97 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 7140.55 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 1964.39 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 36356.63 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 20017.05 0.00 0.00 0.00 0.00 0.00
Pumps General 2145.84 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 86889.94 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 1798.37 2364.37 0.00 0.00 0.00
Cooling 457.73 0.00 0.00 0.00 0.00
Interior Lighting 939.20 0.00 0.00 0.00 0.00
Exterior Lighting 514.89 0.00 0.00 0.00 0.00
Interior Equipment 3601.91 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 1999.19 0.00 0.00 0.00 0.00
Pumps 208.67 0.00 0.00 0.00 0.00
Heat Rejection 20.19 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 1455.91 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 9654.71 3820.28 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 254.73 334.90 0.00 0.00 0.00
Cooling 64.84 0.00 0.00 0.00 0.00
Interior Lighting 133.03 0.00 0.00 0.00 0.00
Exterior Lighting 72.93 0.00 0.00 0.00 0.00
Interior Equipment 510.19 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 283.18 0.00 0.00 0.00 0.00
Pumps 29.56 0.00 0.00 0.00 0.00
Heat Rejection 2.86 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 206.22 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1367.54 541.12 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 254.73 334.90 0.00 0.00 0.00
Cooling 64.84 0.00 0.00 0.00 0.00
Interior Lighting 133.03 0.00 0.00 0.00 0.00
Exterior Lighting 72.93 0.00 0.00 0.00 0.00
Interior Equipment 510.19 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 283.18 0.00 0.00 0.00 0.00
Pumps 29.56 0.00 0.00 0.00 0.00
Heat Rejection 2.86 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 206.22 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1367.54 541.12 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB -28.60 0.00 -28.60 Wetbulb [C] 4.60 310.00
DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 29.20 10.90 21.00 Wetbulb [C] 5.20 220.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.295 0.309 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.295 0.309 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.295 0.309 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.295 0.309 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G WWALL C RES_EXT_WALL 0.30 0.295 0.309 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.295 0.309 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 270.00 180.00  
F2 WWALL SWA RES_EXT_WALL 0.30 0.295 0.309 23.22 270.00 90.00 W
F2 SWALL SWA RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F2 NWALL NWA RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F2 WWALL NWA RES_EXT_WALL 0.30 0.295 0.309 23.22 270.00 90.00 W
F2 EWALL SEA RES_EXT_WALL 0.30 0.295 0.309 23.22 90.00 90.00 E
F2 SWALL SEA RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F2 NWALL NEA RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F2 EWALL NEA RES_EXT_WALL 0.30 0.295 0.309 23.22 90.00 90.00 E
F2 NWALL N1A RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F2 NWALL N2A RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F2 SWALL S1A RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F2 SWALL S2A RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F2 WWALL C RES_EXT_WALL 0.30 0.295 0.309 5.11 270.00 90.00 W
F2 EWALL C RES_EXT_WALL 0.30 0.295 0.309 5.11 90.00 90.00 E
F3 WWALL SWA RES_EXT_WALL 0.30 0.295 0.309 23.22 270.00 90.00 W
F3 SWALL SWA RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F3 NWALL NWA RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F3 WWALL NWA RES_EXT_WALL 0.30 0.295 0.309 23.22 270.00 90.00 W
F3 EWALL SEA RES_EXT_WALL 0.30 0.295 0.309 23.22 90.00 90.00 E
F3 SWALL SEA RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F3 NWALL NEA RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F3 EWALL NEA RES_EXT_WALL 0.30 0.295 0.309 23.22 90.00 90.00 E
F3 NWALL N1A RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F3 NWALL N2A RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F3 SWALL S1A RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F3 SWALL S2A RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F3 WWALL C RES_EXT_WALL 0.30 0.295 0.309 5.11 270.00 90.00 W
F3 EWALL C RES_EXT_WALL 0.30 0.295 0.309 5.11 90.00 90.00 E
F4 WWALL SWA RES_EXT_WALL 0.30 0.295 0.309 23.22 270.00 90.00 W
F4 SWALL SWA RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F4 NWALL NWA RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F4 WWALL NWA RES_EXT_WALL 0.30 0.295 0.309 23.22 270.00 90.00 W
F4 EWALL SEA RES_EXT_WALL 0.30 0.295 0.309 23.22 90.00 90.00 E
F4 SWALL SEA RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F4 NWALL NEA RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F4 EWALL NEA RES_EXT_WALL 0.30 0.295 0.309 23.22 90.00 90.00 E
F4 NWALL N1A RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F4 NWALL N2A RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F4 SWALL S1A RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F4 SWALL S2A RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F4 WWALL C RES_EXT_WALL 0.30 0.295 0.309 5.11 270.00 90.00 W
F4 EWALL C RES_EXT_WALL 0.30 0.295 0.309 5.11 90.00 90.00 E
M WWALL SWA RES_EXT_WALL 0.30 0.295 0.309 23.22 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.295 0.309 23.22 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.295 0.309 23.22 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.295 0.309 23.22 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
M WWALL C RES_EXT_WALL 0.30 0.295 0.309 5.11 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.295 0.309 5.11 90.00 90.00 E
F6 WWALL SWA RES_EXT_WALL 0.30 0.295 0.309 23.22 270.00 90.00 W
F6 SWALL SWA RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F6 NWALL NWA RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F6 WWALL NWA RES_EXT_WALL 0.30 0.295 0.309 23.22 270.00 90.00 W
F6 EWALL SEA RES_EXT_WALL 0.30 0.295 0.309 23.22 90.00 90.00 E
F6 SWALL SEA RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F6 NWALL NEA RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F6 EWALL NEA RES_EXT_WALL 0.30 0.295 0.309 23.22 90.00 90.00 E
F6 NWALL N1A RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F6 NWALL N2A RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F6 SWALL S1A RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F6 SWALL S2A RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F6 WWALL C RES_EXT_WALL 0.30 0.295 0.309 5.11 270.00 90.00 W
F6 EWALL C RES_EXT_WALL 0.30 0.295 0.309 5.11 90.00 90.00 E
F7 WWALL SWA RES_EXT_WALL 0.30 0.295 0.309 23.22 270.00 90.00 W
F7 SWALL SWA RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F7 NWALL NWA RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F7 WWALL NWA RES_EXT_WALL 0.30 0.295 0.309 23.22 270.00 90.00 W
F7 EWALL SEA RES_EXT_WALL 0.30 0.295 0.309 23.22 90.00 90.00 E
F7 SWALL SEA RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F7 NWALL NEA RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F7 EWALL NEA RES_EXT_WALL 0.30 0.295 0.309 23.22 90.00 90.00 E
F7 NWALL N1A RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F7 NWALL N2A RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F7 SWALL S1A RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F7 SWALL S2A RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F7 WWALL C RES_EXT_WALL 0.30 0.295 0.309 5.11 270.00 90.00 W
F7 EWALL C RES_EXT_WALL 0.30 0.295 0.309 5.11 90.00 90.00 E
F8 WWALL SWA RES_EXT_WALL 0.30 0.295 0.309 23.22 270.00 90.00 W
F8 SWALL SWA RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F8 NWALL NWA RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F8 WWALL NWA RES_EXT_WALL 0.30 0.295 0.309 23.22 270.00 90.00 W
F8 EWALL SEA RES_EXT_WALL 0.30 0.295 0.309 23.22 90.00 90.00 E
F8 SWALL SEA RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F8 NWALL NEA RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F8 EWALL NEA RES_EXT_WALL 0.30 0.295 0.309 23.22 90.00 90.00 E
F8 NWALL N1A RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F8 NWALL N2A RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F8 SWALL S1A RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F8 SWALL S2A RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F8 WWALL C RES_EXT_WALL 0.30 0.295 0.309 5.11 270.00 90.00 W
F8 EWALL C RES_EXT_WALL 0.30 0.295 0.309 5.11 90.00 90.00 E
F9 WWALL SWA RES_EXT_WALL 0.30 0.295 0.309 23.22 270.00 90.00 W
F9 SWALL SWA RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F9 NWALL NWA RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F9 WWALL NWA RES_EXT_WALL 0.30 0.295 0.309 23.22 270.00 90.00 W
F9 EWALL SEA RES_EXT_WALL 0.30 0.295 0.309 23.22 90.00 90.00 E
F9 SWALL SEA RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F9 NWALL NEA RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F9 EWALL NEA RES_EXT_WALL 0.30 0.295 0.309 23.22 90.00 90.00 E
F9 NWALL N1A RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F9 NWALL N2A RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
F9 SWALL S1A RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F9 SWALL S2A RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
F9 WWALL C RES_EXT_WALL 0.30 0.295 0.309 5.11 270.00 90.00 W
F9 EWALL C RES_EXT_WALL 0.30 0.295 0.309 5.11 90.00 90.00 E
T WWALL SWA RES_EXT_WALL 0.30 0.295 0.309 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.30 0.219 0.228 88.25 0.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.295 0.309 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.30 0.219 0.228 88.25 0.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.295 0.309 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.30 0.219 0.228 88.25 0.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.295 0.309 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.30 0.219 0.228 88.25 0.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.30 0.219 0.228 88.25 0.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.295 0.309 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.30 0.219 0.228 88.25 0.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.30 0.219 0.228 88.25 0.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.295 0.309 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.30 0.219 0.228 88.25 0.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.295 0.309 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.295 0.309 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.30 0.219 0.228 77.66 0.00 0.00  


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW3 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No G SWALL SWA 180.00 90.00 S
GWINDOW2 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No G WWALL SWA 270.00 90.00 W
GWINDOW4 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No G NWALL NWA 0.00 90.00 N
GWINDOW6 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No G WWALL NWA 270.00 90.00 W
GWINDOW1 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No G SWALL SEA 180.00 90.00 S
GWINDOW8 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No G EWALL SEA 90.00 90.00 E
GWINDOW5 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No G NWALL NEA 0.00 90.00 N
GWINDOW7 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No G EWALL NEA 90.00 90.00 E
GWINDOW9 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No G NWALL N1A 0.00 90.00 N
GWINDOW10 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No G NWALL N2A 0.00 90.00 N
GWINDOW11 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No G SWALL S1A 180.00 90.00 S
GWINDOW12 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No G SWALL S2A 180.00 90.00 S
GWINDOW13 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No G WWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.42_SHGC_0.45 3.36 0.00 0.00 3.36 3.36 2.493 0.426 0.308     No G EWALL C 90.00 90.00 E
F2WINDOW2 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F2 WWALL SWA 270.00 90.00 W
F2WINDOW3 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F2 SWALL SWA 180.00 90.00 S
F2WINDOW4 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F2 NWALL NWA 0.00 90.00 N
F2WINDOW6 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F2 WWALL NWA 270.00 90.00 W
F2WINDOW8 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F2 EWALL SEA 90.00 90.00 E
F2WINDOW1 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F2 SWALL SEA 180.00 90.00 S
F2WINDOW5 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F2 NWALL NEA 0.00 90.00 N
F2WINDOW7 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F2 EWALL NEA 90.00 90.00 E
F2WINDOW9 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F2 NWALL N1A 0.00 90.00 N
F2WINDOW10 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F2 NWALL N2A 0.00 90.00 N
F2WINDOW11 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F2 SWALL S1A 180.00 90.00 S
F2WINDOW12 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F2 SWALL S2A 180.00 90.00 S
F2WINDOW13 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F2 WWALL C 270.00 90.00 W
F2WINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F2 EWALL C 90.00 90.00 E
F3WINDOW2 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F3 WWALL SWA 270.00 90.00 W
F3WINDOW3 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F3 SWALL SWA 180.00 90.00 S
F3WINDOW4 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F3 NWALL NWA 0.00 90.00 N
F3WINDOW6 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F3 WWALL NWA 270.00 90.00 W
F3WINDOW8 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F3 EWALL SEA 90.00 90.00 E
F3WINDOW1 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F3 SWALL SEA 180.00 90.00 S
F3WINDOW5 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F3 NWALL NEA 0.00 90.00 N
F3WINDOW7 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F3 EWALL NEA 90.00 90.00 E
F3WINDOW9 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F3 NWALL N1A 0.00 90.00 N
F3WINDOW10 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F3 NWALL N2A 0.00 90.00 N
F3WINDOW11 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F3 SWALL S1A 180.00 90.00 S
F3WINDOW12 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F3 SWALL S2A 180.00 90.00 S
F3WINDOW13 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F3 WWALL C 270.00 90.00 W
F3WINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F3 EWALL C 90.00 90.00 E
F4WINDOW2 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F4 WWALL SWA 270.00 90.00 W
F4WINDOW3 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F4 SWALL SWA 180.00 90.00 S
F4WINDOW4 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F4 NWALL NWA 0.00 90.00 N
F4WINDOW6 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F4 WWALL NWA 270.00 90.00 W
F4WINDOW8 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F4 EWALL SEA 90.00 90.00 E
F4WINDOW1 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F4 SWALL SEA 180.00 90.00 S
F4WINDOW5 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F4 NWALL NEA 0.00 90.00 N
F4WINDOW7 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F4 EWALL NEA 90.00 90.00 E
F4WINDOW9 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F4 NWALL N1A 0.00 90.00 N
F4WINDOW10 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F4 NWALL N2A 0.00 90.00 N
F4WINDOW11 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F4 SWALL S1A 180.00 90.00 S
F4WINDOW12 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F4 SWALL S2A 180.00 90.00 S
F4WINDOW13 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F4 WWALL C 270.00 90.00 W
F4WINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F4 EWALL C 90.00 90.00 E
MWINDOW2 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No M WWALL SWA 270.00 90.00 W
MWINDOW3 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No M SWALL SWA 180.00 90.00 S
MWINDOW4 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No M NWALL NWA 0.00 90.00 N
MWINDOW6 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No M WWALL NWA 270.00 90.00 W
MWINDOW8 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No M EWALL SEA 90.00 90.00 E
MWINDOW1 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No M SWALL SEA 180.00 90.00 S
MWINDOW5 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No M NWALL NEA 0.00 90.00 N
MWINDOW7 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No M EWALL NEA 90.00 90.00 E
MWINDOW9 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No M NWALL N1A 0.00 90.00 N
MWINDOW10 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No M NWALL N2A 0.00 90.00 N
MWINDOW11 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No M SWALL S1A 180.00 90.00 S
MWINDOW12 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No M SWALL S2A 180.00 90.00 S
MWINDOW13 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No M WWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No M EWALL C 90.00 90.00 E
F6WINDOW2 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F6 WWALL SWA 270.00 90.00 W
F6WINDOW3 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F6 SWALL SWA 180.00 90.00 S
F6WINDOW4 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F6 NWALL NWA 0.00 90.00 N
F6WINDOW6 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F6 WWALL NWA 270.00 90.00 W
F6WINDOW8 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F6 EWALL SEA 90.00 90.00 E
F6WINDOW1 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F6 SWALL SEA 180.00 90.00 S
F6WINDOW5 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F6 NWALL NEA 0.00 90.00 N
F6WINDOW7 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F6 EWALL NEA 90.00 90.00 E
F6WINDOW9 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F6 NWALL N1A 0.00 90.00 N
F6WINDOW10 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F6 NWALL N2A 0.00 90.00 N
F6WINDOW11 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F6 SWALL S1A 180.00 90.00 S
F6WINDOW12 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F6 SWALL S2A 180.00 90.00 S
F6WINDOW13 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F6 WWALL C 270.00 90.00 W
F6WINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F6 EWALL C 90.00 90.00 E
F7WINDOW2 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F7 WWALL SWA 270.00 90.00 W
F7WINDOW3 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F7 SWALL SWA 180.00 90.00 S
F7WINDOW4 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F7 NWALL NWA 0.00 90.00 N
F7WINDOW6 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F7 WWALL NWA 270.00 90.00 W
F7WINDOW8 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F7 EWALL SEA 90.00 90.00 E
F7WINDOW1 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F7 SWALL SEA 180.00 90.00 S
F7WINDOW5 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F7 NWALL NEA 0.00 90.00 N
F7WINDOW7 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F7 EWALL NEA 90.00 90.00 E
F7WINDOW9 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F7 NWALL N1A 0.00 90.00 N
F7WINDOW10 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F7 NWALL N2A 0.00 90.00 N
F7WINDOW11 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F7 SWALL S1A 180.00 90.00 S
F7WINDOW12 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F7 SWALL S2A 180.00 90.00 S
F7WINDOW13 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F7 WWALL C 270.00 90.00 W
F7WINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F7 EWALL C 90.00 90.00 E
F8WINDOW2 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F8 WWALL SWA 270.00 90.00 W
F8WINDOW3 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F8 SWALL SWA 180.00 90.00 S
F8WINDOW4 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F8 NWALL NWA 0.00 90.00 N
F8WINDOW6 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F8 WWALL NWA 270.00 90.00 W
F8WINDOW8 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F8 EWALL SEA 90.00 90.00 E
F8WINDOW1 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F8 SWALL SEA 180.00 90.00 S
F8WINDOW5 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F8 NWALL NEA 0.00 90.00 N
F8WINDOW7 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F8 EWALL NEA 90.00 90.00 E
F8WINDOW9 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F8 NWALL N1A 0.00 90.00 N
F8WINDOW10 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F8 NWALL N2A 0.00 90.00 N
F8WINDOW11 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F8 SWALL S1A 180.00 90.00 S
F8WINDOW12 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F8 SWALL S2A 180.00 90.00 S
F8WINDOW13 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F8 WWALL C 270.00 90.00 W
F8WINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F8 EWALL C 90.00 90.00 E
F9WINDOW2 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F9 WWALL SWA 270.00 90.00 W
F9WINDOW3 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F9 SWALL SWA 180.00 90.00 S
F9WINDOW4 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F9 NWALL NWA 0.00 90.00 N
F9WINDOW6 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F9 WWALL NWA 270.00 90.00 W
F9WINDOW8 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F9 EWALL SEA 90.00 90.00 E
F9WINDOW1 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F9 SWALL SEA 180.00 90.00 S
F9WINDOW5 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F9 NWALL NEA 0.00 90.00 N
F9WINDOW7 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F9 EWALL NEA 90.00 90.00 E
F9WINDOW9 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F9 NWALL N1A 0.00 90.00 N
F9WINDOW10 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F9 NWALL N2A 0.00 90.00 N
F9WINDOW11 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F9 SWALL S1A 180.00 90.00 S
F9WINDOW12 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F9 SWALL S2A 180.00 90.00 S
F9WINDOW13 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F9 WWALL C 270.00 90.00 W
F9WINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F9 EWALL C 90.00 90.00 E
TWINDOW2 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No T WWALL SWA 270.00 90.00 W
TWINDOW3 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No T SWALL SWA 180.00 90.00 S
TWINDOW4 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No T NWALL NWA 0.00 90.00 N
TWINDOW6 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No T WWALL NWA 270.00 90.00 W
TWINDOW8 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No T EWALL SEA 90.00 90.00 E
TWINDOW1 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No T SWALL SEA 180.00 90.00 S
TWINDOW5 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No T NWALL NEA 0.00 90.00 N
TWINDOW7 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No T EWALL NEA 90.00 90.00 E
TWINDOW9 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No T NWALL N1A 0.00 90.00 N
TWINDOW10 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No T NWALL N2A 0.00 90.00 N
TWINDOW11 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No T SWALL S1A 180.00 90.00 S
TWINDOW12 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No T SWALL S2A 180.00 90.00 S
TWINDOW13 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No T WWALL C 270.00 90.00 W
TWINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No T EWALL C 90.00 90.00 E
Total or Average           1150.39 2.493 0.426 0.308              
North Total or Average           423.59 2.493 0.426 0.308              
Non-North Total or Average           726.80 2.493 0.426 0.308              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
G SW APARTMENT_LIGHTS_HARDWIRED G SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G NW APARTMENT_LIGHTS_HARDWIRED G NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
OFFICE_LIGHTS_HARDWIRED OFFICE 14.7681 88.25 1303.26 GeneralLights LTG_OFF_SCH 62.05 168.00 61.07 0.0000 Y 14.94
G NE APARTMENT_LIGHTS_HARDWIRED G NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G N1 APARTMENT_LIGHTS_HARDWIRED G N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G N2 APARTMENT_LIGHTS_HARDWIRED G N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G S1 APARTMENT_LIGHTS_HARDWIRED G S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G S2 APARTMENT_LIGHTS_HARDWIRED G S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G CORRIDOR_LIGHTS_HARDWIRED G CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F2 SW APARTMENT_LIGHTS_HARDWIRED F2 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 NW APARTMENT_LIGHTS_HARDWIRED F2 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 SE APARTMENT_LIGHTS_HARDWIRED F2 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 NE APARTMENT_LIGHTS_HARDWIRED F2 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 N1 APARTMENT_LIGHTS_HARDWIRED F2 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 N2 APARTMENT_LIGHTS_HARDWIRED F2 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 S1 APARTMENT_LIGHTS_HARDWIRED F2 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 S2 APARTMENT_LIGHTS_HARDWIRED F2 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 CORRIDOR_LIGHTS_HARDWIRED F2 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F3 SW APARTMENT_LIGHTS_HARDWIRED F3 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 NW APARTMENT_LIGHTS_HARDWIRED F3 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 SE APARTMENT_LIGHTS_HARDWIRED F3 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 NE APARTMENT_LIGHTS_HARDWIRED F3 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 N1 APARTMENT_LIGHTS_HARDWIRED F3 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 N2 APARTMENT_LIGHTS_HARDWIRED F3 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 S1 APARTMENT_LIGHTS_HARDWIRED F3 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 S2 APARTMENT_LIGHTS_HARDWIRED F3 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 CORRIDOR_LIGHTS_HARDWIRED F3 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F4 SW APARTMENT_LIGHTS_HARDWIRED F4 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 NW APARTMENT_LIGHTS_HARDWIRED F4 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 SE APARTMENT_LIGHTS_HARDWIRED F4 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 NE APARTMENT_LIGHTS_HARDWIRED F4 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 N1 APARTMENT_LIGHTS_HARDWIRED F4 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 N2 APARTMENT_LIGHTS_HARDWIRED F4 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 S1 APARTMENT_LIGHTS_HARDWIRED F4 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 S2 APARTMENT_LIGHTS_HARDWIRED F4 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 CORRIDOR_LIGHTS_HARDWIRED F4 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
M SW APARTMENT_LIGHTS_HARDWIRED M SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M NW APARTMENT_LIGHTS_HARDWIRED M NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M SE APARTMENT_LIGHTS_HARDWIRED M SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M NE APARTMENT_LIGHTS_HARDWIRED M NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M N1 APARTMENT_LIGHTS_HARDWIRED M N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M N2 APARTMENT_LIGHTS_HARDWIRED M N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M S1 APARTMENT_LIGHTS_HARDWIRED M S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M S2 APARTMENT_LIGHTS_HARDWIRED M S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M CORRIDOR_LIGHTS_HARDWIRED M CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F6 SW APARTMENT_LIGHTS_HARDWIRED F6 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 NW APARTMENT_LIGHTS_HARDWIRED F6 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 SE APARTMENT_LIGHTS_HARDWIRED F6 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 NE APARTMENT_LIGHTS_HARDWIRED F6 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 N1 APARTMENT_LIGHTS_HARDWIRED F6 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 N2 APARTMENT_LIGHTS_HARDWIRED F6 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 S1 APARTMENT_LIGHTS_HARDWIRED F6 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 S2 APARTMENT_LIGHTS_HARDWIRED F6 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 CORRIDOR_LIGHTS_HARDWIRED F6 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F7 SW APARTMENT_LIGHTS_HARDWIRED F7 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 NW APARTMENT_LIGHTS_HARDWIRED F7 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 SE APARTMENT_LIGHTS_HARDWIRED F7 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 NE APARTMENT_LIGHTS_HARDWIRED F7 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 N1 APARTMENT_LIGHTS_HARDWIRED F7 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 N2 APARTMENT_LIGHTS_HARDWIRED F7 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 S1 APARTMENT_LIGHTS_HARDWIRED F7 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 S2 APARTMENT_LIGHTS_HARDWIRED F7 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 CORRIDOR_LIGHTS_HARDWIRED F7 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F8 SW APARTMENT_LIGHTS_HARDWIRED F8 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 NW APARTMENT_LIGHTS_HARDWIRED F8 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 SE APARTMENT_LIGHTS_HARDWIRED F8 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 NE APARTMENT_LIGHTS_HARDWIRED F8 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 N1 APARTMENT_LIGHTS_HARDWIRED F8 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 N2 APARTMENT_LIGHTS_HARDWIRED F8 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 S1 APARTMENT_LIGHTS_HARDWIRED F8 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 S2 APARTMENT_LIGHTS_HARDWIRED F8 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 CORRIDOR_LIGHTS_HARDWIRED F8 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F9 SW APARTMENT_LIGHTS_HARDWIRED F9 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 NW APARTMENT_LIGHTS_HARDWIRED F9 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 SE APARTMENT_LIGHTS_HARDWIRED F9 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 NE APARTMENT_LIGHTS_HARDWIRED F9 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 N1 APARTMENT_LIGHTS_HARDWIRED F9 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 N2 APARTMENT_LIGHTS_HARDWIRED F9 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 S1 APARTMENT_LIGHTS_HARDWIRED F9 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 S2 APARTMENT_LIGHTS_HARDWIRED F9 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 CORRIDOR_LIGHTS_HARDWIRED F9 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
T SW APARTMENT_LIGHTS_HARDWIRED T SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T NW APARTMENT_LIGHTS_HARDWIRED T NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T SE APARTMENT_LIGHTS_HARDWIRED T SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T NE APARTMENT_LIGHTS_HARDWIRED T NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T N1 APARTMENT_LIGHTS_HARDWIRED T N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T N2 APARTMENT_LIGHTS_HARDWIRED T N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T S1 APARTMENT_LIGHTS_HARDWIRED T S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T S2 APARTMENT_LIGHTS_HARDWIRED T S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T CORRIDOR_LIGHTS_HARDWIRED T CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
G SW APARTMENT_LIGHTS_PLUGIN G SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G NW APARTMENT_LIGHTS_PLUGIN G NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
OFFICE_LIGHTS_PLUGIN OFFICE 14.7681 88.25 1303.26 GeneralLights-plugin LTG_OFF_SCH 62.05 168.00 61.07 0.0000 Y 14.94
G NE APARTMENT_LIGHTS_PLUGIN G NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G N1 APARTMENT_LIGHTS_PLUGIN G N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G N2 APARTMENT_LIGHTS_PLUGIN G N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G S1 APARTMENT_LIGHTS_PLUGIN G S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G S2 APARTMENT_LIGHTS_PLUGIN G S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 SW APARTMENT_LIGHTS_PLUGIN F2 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 NW APARTMENT_LIGHTS_PLUGIN F2 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 SE APARTMENT_LIGHTS_PLUGIN F2 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 NE APARTMENT_LIGHTS_PLUGIN F2 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 N1 APARTMENT_LIGHTS_PLUGIN F2 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 N2 APARTMENT_LIGHTS_PLUGIN F2 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 S1 APARTMENT_LIGHTS_PLUGIN F2 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 S2 APARTMENT_LIGHTS_PLUGIN F2 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 SW APARTMENT_LIGHTS_PLUGIN F3 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 NW APARTMENT_LIGHTS_PLUGIN F3 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 SE APARTMENT_LIGHTS_PLUGIN F3 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 NE APARTMENT_LIGHTS_PLUGIN F3 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 N1 APARTMENT_LIGHTS_PLUGIN F3 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 N2 APARTMENT_LIGHTS_PLUGIN F3 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 S1 APARTMENT_LIGHTS_PLUGIN F3 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 S2 APARTMENT_LIGHTS_PLUGIN F3 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 SW APARTMENT_LIGHTS_PLUGIN F4 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 NW APARTMENT_LIGHTS_PLUGIN F4 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 SE APARTMENT_LIGHTS_PLUGIN F4 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 NE APARTMENT_LIGHTS_PLUGIN F4 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 N1 APARTMENT_LIGHTS_PLUGIN F4 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 N2 APARTMENT_LIGHTS_PLUGIN F4 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 S1 APARTMENT_LIGHTS_PLUGIN F4 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 S2 APARTMENT_LIGHTS_PLUGIN F4 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M SW APARTMENT_LIGHTS_PLUGIN M SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M NW APARTMENT_LIGHTS_PLUGIN M NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M SE APARTMENT_LIGHTS_PLUGIN M SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M NE APARTMENT_LIGHTS_PLUGIN M NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M N1 APARTMENT_LIGHTS_PLUGIN M N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M N2 APARTMENT_LIGHTS_PLUGIN M N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M S1 APARTMENT_LIGHTS_PLUGIN M S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M S2 APARTMENT_LIGHTS_PLUGIN M S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M CORRIDOR_LIGHTS_PLUGIN M CORRIDOR 6.7128 77.66 521.30 GeneralLights-plugin LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F6 SW APARTMENT_LIGHTS_PLUGIN F6 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 NW APARTMENT_LIGHTS_PLUGIN F6 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 SE APARTMENT_LIGHTS_PLUGIN F6 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 NE APARTMENT_LIGHTS_PLUGIN F6 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 N1 APARTMENT_LIGHTS_PLUGIN F6 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 N2 APARTMENT_LIGHTS_PLUGIN F6 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 S1 APARTMENT_LIGHTS_PLUGIN F6 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 S2 APARTMENT_LIGHTS_PLUGIN F6 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 SW APARTMENT_LIGHTS_PLUGIN F7 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 NW APARTMENT_LIGHTS_PLUGIN F7 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 SE APARTMENT_LIGHTS_PLUGIN F7 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 NE APARTMENT_LIGHTS_PLUGIN F7 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 N1 APARTMENT_LIGHTS_PLUGIN F7 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 N2 APARTMENT_LIGHTS_PLUGIN F7 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 S1 APARTMENT_LIGHTS_PLUGIN F7 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 S2 APARTMENT_LIGHTS_PLUGIN F7 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 SW APARTMENT_LIGHTS_PLUGIN F8 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 NW APARTMENT_LIGHTS_PLUGIN F8 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 SE APARTMENT_LIGHTS_PLUGIN F8 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 NE APARTMENT_LIGHTS_PLUGIN F8 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 N1 APARTMENT_LIGHTS_PLUGIN F8 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 N2 APARTMENT_LIGHTS_PLUGIN F8 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 S1 APARTMENT_LIGHTS_PLUGIN F8 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 S2 APARTMENT_LIGHTS_PLUGIN F8 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 SW APARTMENT_LIGHTS_PLUGIN F9 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 NW APARTMENT_LIGHTS_PLUGIN F9 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 SE APARTMENT_LIGHTS_PLUGIN F9 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 NE APARTMENT_LIGHTS_PLUGIN F9 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 N1 APARTMENT_LIGHTS_PLUGIN F9 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 N2 APARTMENT_LIGHTS_PLUGIN F9 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 S1 APARTMENT_LIGHTS_PLUGIN F9 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 S2 APARTMENT_LIGHTS_PLUGIN F9 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T SW APARTMENT_LIGHTS_PLUGIN T SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T NW APARTMENT_LIGHTS_PLUGIN T NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T SE APARTMENT_LIGHTS_PLUGIN T SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T NE APARTMENT_LIGHTS_PLUGIN T NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T N1 APARTMENT_LIGHTS_PLUGIN T N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T N2 APARTMENT_LIGHTS_PLUGIN T N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T S1 APARTMENT_LIGHTS_PLUGIN T S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T S2 APARTMENT_LIGHTS_PLUGIN T S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
Interior Lighting Total   2.2679 14974.03 33959.19               296.56


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 10364.00 AstronomicalClock -   83.57 83.57 162.58
Exterior Lighting Total 10364.00           162.58



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
CENTRAL BOILER Boiler:HotWater 303615.53 0.75    
CENTRAL TOWER EvaporativeFluidCooler:SingleSpeed 242892.43      


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
HEAT PUMP COOLING MODE AIRLOOP G SW Coil:Cooling:WaterToAirHeatPump:EquationFit   3494.72 2266.68 1228.03 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3510.52 2253.89 1256.63 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP OFFICE Coil:Cooling:WaterToAirHeatPump:EquationFit   5429.48 3594.63 1834.85 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3735.54 2316.37 1419.17 0.62 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2734.62 1641.03 1093.59 0.60 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2748.65 1645.72 1102.92 0.60 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2553.60 1601.76 951.84 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2529.13 1595.37 933.75 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4535.68 2987.25 1548.43 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4106.48 2677.26 1429.22 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4544.68 2986.41 1558.27 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3520.63 2237.83 1282.80 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2311.88 1433.75 878.13 0.62 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2290.15 1418.48 871.67 0.62 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3179.81 2044.87 1134.93 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3215.43 2070.74 1144.69 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4615.28 3021.57 1593.71 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4214.15 2730.82 1483.33 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4339.47 2814.85 1524.62 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3707.02 2343.93 1363.09 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2404.18 1488.82 915.36 0.62 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2382.52 1473.64 908.88 0.62 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3273.79 2099.72 1174.07 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3290.67 2111.98 1178.69 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4662.50 3038.66 1623.84 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4264.62 2751.14 1513.48 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4364.16 2816.41 1547.75 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3937.18 2477.15 1460.03 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2441.97 1508.07 933.90 0.62 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2420.29 1492.93 927.36 0.62 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3313.17 2118.44 1194.73 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3327.37 2128.73 1198.64 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4727.00 3071.57 1655.43 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4331.99 2786.74 1545.25 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4431.34 2851.77 1579.56 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4113.64 2580.76 1532.89 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2497.40 1541.08 956.32 0.62 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2477.54 1527.09 950.45 0.62 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3369.75 2151.38 1218.37 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3383.58 2161.40 1222.18 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4724.80 3056.08 1668.72 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4310.11 2760.44 1549.66 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4414.82 2829.13 1585.70 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4357.64 2719.10 1638.54 0.62 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2628.86 1614.47 1014.39 0.61 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2634.80 1616.26 1018.54 0.61 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3342.16 2125.01 1217.14 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3355.99 2135.01 1220.98 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4731.90 3051.39 1680.51 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4338.99 2770.20 1568.79 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4424.29 2826.63 1597.67 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4542.98 2824.74 1718.24 0.62 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2746.72 1682.11 1064.62 0.61 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2752.95 1684.00 1068.95 0.61 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3341.47 2118.90 1222.58 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3355.33 2128.89 1226.44 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4752.25 3057.35 1694.91 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4502.70 2867.92 1634.78 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4498.51 2867.45 1631.06 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4717.07 2925.45 1791.62 0.62 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2859.93 1748.56 1111.37 0.61 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2866.33 1750.50 1115.83 0.61 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3354.68 2123.37 1231.30 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3368.59 2133.39 1235.20 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4854.53 3125.15 1729.38 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4762.06 3034.87 1727.18 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4768.51 3039.08 1729.43 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   5004.16 3100.42 1903.74 0.62 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3067.86 1881.47 1186.39 0.61 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3074.38 1883.43 1190.95 0.61 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3428.79 2171.46 1257.33 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3441.45 2180.80 1260.65 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5702.34 3721.46 1980.87 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5362.38 3461.01 1901.37 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SE Coil:Cooling:WaterToAirHeatPump:EquationFit   5332.29 3448.08 1884.21 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NE Coil:Cooling:WaterToAirHeatPump:EquationFit   5603.29 3524.05 2079.23 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3839.49 2388.13 1451.37 0.62 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3845.33 2390.75 1454.58 0.62 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   4277.30 2777.85 1499.45 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   4290.87 2787.76 1503.11 0.65 0.00    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
None            


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
HEAT PUMP HEATING MODE AIRLOOP G SW Coil:Heating:WaterToAirHeatPump:EquationFit   3494.72 0.00
HEAT PUMP HEATING MODE AIRLOOP G NW Coil:Heating:WaterToAirHeatPump:EquationFit   3510.52 0.00
HEAT PUMP HEATING MODE AIRLOOP OFFICE Coil:Heating:WaterToAirHeatPump:EquationFit   5429.48 0.00
HEAT PUMP HEATING MODE AIRLOOP G NE Coil:Heating:WaterToAirHeatPump:EquationFit   3735.54 0.00
HEAT PUMP HEATING MODE AIRLOOP G N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2734.62 0.00
HEAT PUMP HEATING MODE AIRLOOP G N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2748.65 0.00
HEAT PUMP HEATING MODE AIRLOOP G S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2553.60 0.00
HEAT PUMP HEATING MODE AIRLOOP G S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2529.13 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4535.68 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4106.48 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4544.68 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3520.63 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2311.88 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2290.15 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3179.81 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3215.43 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4615.28 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4214.15 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4339.47 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3707.02 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2404.18 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2382.52 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3273.79 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3290.67 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4662.50 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4264.62 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4364.16 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3937.18 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2441.97 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2420.29 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3313.17 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3327.37 0.00
HEAT PUMP HEATING MODE AIRLOOP M SW Coil:Heating:WaterToAirHeatPump:EquationFit   4727.00 0.00
HEAT PUMP HEATING MODE AIRLOOP M NW Coil:Heating:WaterToAirHeatPump:EquationFit   4331.99 0.00
HEAT PUMP HEATING MODE AIRLOOP M SE Coil:Heating:WaterToAirHeatPump:EquationFit   4431.34 0.00
HEAT PUMP HEATING MODE AIRLOOP M NE Coil:Heating:WaterToAirHeatPump:EquationFit   4113.64 0.00
HEAT PUMP HEATING MODE AIRLOOP M N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2497.40 0.00
HEAT PUMP HEATING MODE AIRLOOP M N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2477.54 0.00
HEAT PUMP HEATING MODE AIRLOOP M S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3369.75 0.00
HEAT PUMP HEATING MODE AIRLOOP M S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3383.58 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4724.80 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4310.11 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4414.82 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4357.64 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2628.86 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2634.80 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3342.16 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3355.99 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4731.90 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4338.99 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4424.29 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4542.98 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2746.72 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2752.95 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3341.47 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3355.33 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4752.25 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4502.70 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4498.51 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4717.07 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2859.93 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2866.33 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3354.68 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3368.59 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4854.53 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4762.06 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4768.51 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NE Coil:Heating:WaterToAirHeatPump:EquationFit   5004.16 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3067.86 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3074.38 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3428.79 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3441.45 0.00
HEAT PUMP HEATING MODE AIRLOOP T SW Coil:Heating:WaterToAirHeatPump:EquationFit   5702.34 0.00
HEAT PUMP HEATING MODE AIRLOOP T NW Coil:Heating:WaterToAirHeatPump:EquationFit   5362.38 0.00
HEAT PUMP HEATING MODE AIRLOOP T SE Coil:Heating:WaterToAirHeatPump:EquationFit   5332.29 0.00
HEAT PUMP HEATING MODE AIRLOOP T NE Coil:Heating:WaterToAirHeatPump:EquationFit   5603.29 0.00
HEAT PUMP HEATING MODE AIRLOOP T N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3839.49 0.00
HEAT PUMP HEATING MODE AIRLOOP T N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3845.33 0.00
HEAT PUMP HEATING MODE AIRLOOP T S1 Coil:Heating:WaterToAirHeatPump:EquationFit   4277.30 0.00
HEAT PUMP HEATING MODE AIRLOOP T S2 Coil:Heating:WaterToAirHeatPump:EquationFit   4290.87 0.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW Coil:Heating:Electric   5790.18 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW Coil:Heating:Electric   5797.70 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE Coil:Heating:Electric   6934.29 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE Coil:Heating:Electric   5800.02 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 Coil:Heating:Electric   4447.31 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 Coil:Heating:Electric   4447.35 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 Coil:Heating:Electric   4437.51 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 Coil:Heating:Electric   4443.83 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW Coil:Heating:Electric   5756.77 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW Coil:Heating:Electric   5760.11 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE Coil:Heating:Electric   5771.78 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE Coil:Heating:Electric   5757.17 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 Coil:Heating:Electric   4049.99 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 Coil:Heating:Electric   4049.93 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 Coil:Heating:Electric   4049.80 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 Coil:Heating:Electric   4050.82 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW Coil:Heating:Electric   5934.99 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW Coil:Heating:Electric   5946.68 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE Coil:Heating:Electric   5930.08 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE Coil:Heating:Electric   5939.98 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 Coil:Heating:Electric   4101.16 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 Coil:Heating:Electric   4101.01 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 Coil:Heating:Electric   4090.68 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 Coil:Heating:Electric   4090.69 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW Coil:Heating:Electric   6165.08 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW Coil:Heating:Electric   6181.89 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE Coil:Heating:Electric   6155.84 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE Coil:Heating:Electric   6172.48 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 Coil:Heating:Electric   4230.13 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 Coil:Heating:Electric   4229.93 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 Coil:Heating:Electric   4214.22 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 Coil:Heating:Electric   4214.03 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW Coil:Heating:Electric   6348.25 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW Coil:Heating:Electric   6367.52 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE Coil:Heating:Electric   6336.76 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE Coil:Heating:Electric   6356.00 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 Coil:Heating:Electric   4330.10 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 Coil:Heating:Electric   4329.84 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 Coil:Heating:Electric   4311.63 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 Coil:Heating:Electric   4311.38 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW Coil:Heating:Electric   6570.94 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW Coil:Heating:Electric   6593.79 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE Coil:Heating:Electric   6557.70 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE Coil:Heating:Electric   6580.55 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 Coil:Heating:Electric   4480.77 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 Coil:Heating:Electric   4480.48 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 Coil:Heating:Electric   4458.67 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 Coil:Heating:Electric   4458.38 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW Coil:Heating:Electric   6750.30 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW Coil:Heating:Electric   6775.17 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE Coil:Heating:Electric   6735.63 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE Coil:Heating:Electric   6760.49 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 Coil:Heating:Electric   4596.67 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 Coil:Heating:Electric   4596.35 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 Coil:Heating:Electric   4572.53 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 Coil:Heating:Electric   4572.21 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW Coil:Heating:Electric   6924.59 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW Coil:Heating:Electric   6950.81 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE Coil:Heating:Electric   6908.67 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE Coil:Heating:Electric   6934.89 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 Coil:Heating:Electric   4713.56 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 Coil:Heating:Electric   4713.21 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 Coil:Heating:Electric   4688.06 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 Coil:Heating:Electric   4687.71 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW Coil:Heating:Electric   7248.20 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW Coil:Heating:Electric   7272.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE Coil:Heating:Electric   7231.03 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE Coil:Heating:Electric   7255.12 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 Coil:Heating:Electric   4969.48 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 Coil:Heating:Electric   4969.10 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 Coil:Heating:Electric   4945.66 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 Coil:Heating:Electric   4945.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW Coil:Heating:Electric   8113.34 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW Coil:Heating:Electric   8145.63 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE Coil:Heating:Electric   8096.51 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE Coil:Heating:Electric   8128.80 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 Coil:Heating:Electric   5870.68 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 Coil:Heating:Electric   5870.29 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 Coil:Heating:Electric   5835.47 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 Coil:Heating:Electric   5835.08 1.00


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
AIRLOOP G SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 238.81 1160.84 1.00 General
AIRLOOP G NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 237.16 1160.84 1.00 General
AIRLOOP OFFICE SUPPLY FAN Fan:OnOff 0.54 622.50 0.33 383.96 1160.84 1.00 General
AIRLOOP G NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 237.29 1160.84 1.00 General
AIRLOOP G N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 162.64 1160.84 1.00 General
AIRLOOP G N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 162.65 1160.84 1.00 General
AIRLOOP G S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 162.10 1160.84 1.00 General
AIRLOOP G S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 162.45 1160.84 1.00 General
AIRLOOP F2 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 320.93 1160.84 1.00 General
AIRLOOP F2 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 286.26 1160.84 1.00 General
AIRLOOP F2 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.27 318.37 1160.84 1.00 General
AIRLOOP F2 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 234.90 1160.84 1.00 General
AIRLOOP F2 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 147.44 1160.84 1.00 General
AIRLOOP F2 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 145.69 1160.84 1.00 General
AIRLOOP F2 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 212.88 1160.84 1.00 General
AIRLOOP F2 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 215.87 1160.84 1.00 General
AIRLOOP F3 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 323.26 1160.84 1.00 General
AIRLOOP F3 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 290.25 1160.84 1.00 General
AIRLOOP F3 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 296.96 1160.84 1.00 General
AIRLOOP F3 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 244.97 1160.84 1.00 General
AIRLOOP F3 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 152.91 1160.84 1.00 General
AIRLOOP F3 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 151.17 1160.84 1.00 General
AIRLOOP F3 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 218.25 1160.84 1.00 General
AIRLOOP F3 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 219.67 1160.84 1.00 General
AIRLOOP F4 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 324.03 1160.84 1.00 General
AIRLOOP F4 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 291.42 1160.84 1.00 General
AIRLOOP F4 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 295.96 1160.84 1.00 General
AIRLOOP F4 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 257.80 1160.84 1.00 General
AIRLOOP F4 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 154.48 1160.84 1.00 General
AIRLOOP F4 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 152.75 1160.84 1.00 General
AIRLOOP F4 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 219.69 1160.84 1.00 General
AIRLOOP F4 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 220.89 1160.84 1.00 General
AIRLOOP M SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 326.85 1160.84 1.00 General
AIRLOOP M NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 294.58 1160.84 1.00 General
AIRLOOP M SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 299.08 1160.84 1.00 General
AIRLOOP M NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 267.92 1160.84 1.00 General
AIRLOOP M N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 157.76 1160.84 1.00 General
AIRLOOP M N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 156.14 1160.84 1.00 General
AIRLOOP M S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 222.91 1160.84 1.00 General
AIRLOOP M S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 224.07 1160.84 1.00 General
AIRLOOP F6 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 322.99 1160.84 1.00 General
AIRLOOP F6 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 290.75 1160.84 1.00 General
AIRLOOP F6 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 295.67 1160.84 1.00 General
AIRLOOP F6 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 280.30 1160.84 1.00 General
AIRLOOP F6 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 164.47 1160.84 1.00 General
AIRLOOP F6 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 164.45 1160.84 1.00 General
AIRLOOP F6 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 219.38 1160.84 1.00 General
AIRLOOP F6 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 220.53 1160.84 1.00 General
AIRLOOP F7 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 321.73 1160.84 1.00 General
AIRLOOP F7 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 291.03 1160.84 1.00 General
AIRLOOP F7 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 294.69 1160.84 1.00 General
AIRLOOP F7 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 290.22 1160.84 1.00 General
AIRLOOP F7 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.15 170.86 1160.84 1.00 General
AIRLOOP F7 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.15 170.84 1160.84 1.00 General
AIRLOOP F7 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 218.24 1160.84 1.00 General
AIRLOOP F7 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 219.40 1160.84 1.00 General
AIRLOOP F8 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 321.78 1160.84 1.00 General
AIRLOOP F8 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 300.72 1160.84 1.00 General
AIRLOOP F8 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 298.39 1160.84 1.00 General
AIRLOOP F8 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 299.84 1160.84 1.00 General
AIRLOOP F8 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.15 177.31 1160.84 1.00 General
AIRLOOP F8 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.15 177.29 1160.84 1.00 General
AIRLOOP F8 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 218.37 1160.84 1.00 General
AIRLOOP F8 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 219.53 1160.84 1.00 General
AIRLOOP F9 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 330.23 1160.84 1.00 General
AIRLOOP F9 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.27 318.45 1160.84 1.00 General
AIRLOOP F9 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.27 316.17 1160.84 1.00 General
AIRLOOP F9 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.27 317.50 1160.84 1.00 General
AIRLOOP F9 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 191.43 1160.84 1.00 General
AIRLOOP F9 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 191.41 1160.84 1.00 General
AIRLOOP F9 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 223.39 1160.84 1.00 General
AIRLOOP F9 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 224.62 1160.84 1.00 General
AIRLOOP T SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.34 396.02 1160.84 1.00 General
AIRLOOP T NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 366.62 1160.84 1.00 General
AIRLOOP T SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 363.91 1160.84 1.00 General
AIRLOOP T NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 365.69 1160.84 1.00 General
AIRLOOP T N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 241.15 1160.84 1.00 General
AIRLOOP T N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 241.13 1160.84 1.00 General
AIRLOOP T S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 293.11 1160.84 1.00 General
AIRLOOP T S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 294.26 1160.84 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
SHWSYS1 PUMP Pump:ConstantSpeed Intermittent 29891.00 0.0003 36.93 127739.32 0.30
PLANT CIRC PUMP Pump:ConstantSpeed Intermittent 224180.02 0.0066 2108.92 319344.75 0.90


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
SHWSYS1 WATER HEATER WaterHeater:Mixed 2.27 175842.64 0.80 0.00 0.00



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 2079.14 2494.97 0.171 0.206 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 28.33 0.01308
G NW APARTMENT 1863.01 2235.61 0.154 0.184 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 26.58 0.01308
OFFICE 3342.87 4011.44 0.276 0.331 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 28.93 0.01308
G NE APARTMENT 1295.48 1554.57 0.107 0.128 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 25.47 0.01308
G N1 APARTMENT 874.16 1048.99 0.072 0.086 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.95 0.01308
G N2 APARTMENT 856.07 1027.29 0.071 0.085 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.95 0.01308
G S1 APARTMENT 1341.65 1609.98 0.111 0.133 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.06 0.01308
G S2 APARTMENT 1409.47 1691.36 0.116 0.139 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.06 0.01308
F2 SW APARTMENT 2793.98 3352.78 0.230 0.276 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 27.13 0.01308
F2 NW APARTMENT 2492.18 2990.62 0.205 0.247 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 26.18 0.01308
F2 SE APARTMENT 2771.71 3326.05 0.229 0.274 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 28.93 0.01308
F2 NE APARTMENT 1853.14 2223.77 0.153 0.183 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 25.47 0.01308
F2 N1 APARTMENT 1283.65 1540.38 0.106 0.127 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.95 0.01308
F2 N2 APARTMENT 1268.39 1522.07 0.105 0.126 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.95 0.01308
F2 S1 APARTMENT 1853.41 2224.09 0.153 0.183 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.06 0.01308
F2 S2 APARTMENT 1879.49 2255.38 0.155 0.186 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.06 0.01308
F3 SW APARTMENT 2814.26 3377.12 0.232 0.278 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 27.13 0.01308
F3 NW APARTMENT 2526.85 3032.22 0.208 0.250 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 26.58 0.01308
F3 SE APARTMENT 2585.24 3102.29 0.213 0.256 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 28.93 0.01308
F3 NE APARTMENT 1893.18 2271.81 0.156 0.187 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 25.47 0.01308
F3 N1 APARTMENT 1331.28 1597.53 0.110 0.132 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.95 0.01308
F3 N2 APARTMENT 1316.12 1579.34 0.109 0.130 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.95 0.01308
F3 S1 APARTMENT 1900.18 2280.21 0.157 0.188 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.06 0.01308
F3 S2 APARTMENT 1912.54 2295.04 0.158 0.189 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.06 0.01308
F4 SW APARTMENT 2820.89 3385.07 0.233 0.279 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 27.13 0.01308
F4 NW APARTMENT 2537.00 3044.40 0.209 0.251 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 26.58 0.01308
F4 SE APARTMENT 2576.51 3091.82 0.212 0.255 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 28.93 0.01308
F4 NE APARTMENT 1899.01 2278.81 0.157 0.188 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 25.47 0.01308
F4 N1 APARTMENT 1344.94 1613.93 0.111 0.133 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.95 0.01308
F4 N2 APARTMENT 1329.85 1595.82 0.110 0.132 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.95 0.01308
F4 S1 APARTMENT 1912.70 2295.24 0.158 0.189 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.06 0.01308
F4 S2 APARTMENT 1923.09 2307.70 0.159 0.190 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.06 0.01308
M SW APARTMENT 2845.39 3414.47 0.235 0.282 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 27.13 0.01308
M NW APARTMENT 2564.42 3077.31 0.211 0.254 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 26.58 0.01308
M SE APARTMENT 2603.66 3124.39 0.215 0.258 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 28.93 0.01308
M NE APARTMENT 1922.23 2306.68 0.159 0.190 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 25.47 0.01308
M N1 APARTMENT 1373.41 1648.10 0.113 0.136 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.95 0.01308
M N2 APARTMENT 1358.38 1630.05 0.112 0.134 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.95 0.01308
M S1 APARTMENT 1940.69 2328.82 0.160 0.192 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.06 0.01308
M S2 APARTMENT 1950.78 2340.94 0.161 0.193 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.06 0.01308
F6 SW APARTMENT 2811.76 3374.12 0.232 0.278 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 28.11 0.01308
F6 NW APARTMENT 2531.08 3037.30 0.209 0.250 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 26.58 0.01308
F6 SE APARTMENT 2573.94 3088.73 0.212 0.255 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 28.93 0.01308
F6 NE APARTMENT 1887.02 2264.43 0.156 0.187 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 25.88 0.01308
F6 N1 APARTMENT 1343.92 1612.70 0.111 0.133 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.95 0.01308
F6 N2 APARTMENT 1329.01 1594.81 0.110 0.132 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.95 0.01308
F6 S1 APARTMENT 1909.89 2291.87 0.157 0.189 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.06 0.01308
F6 S2 APARTMENT 1919.96 2303.95 0.158 0.190 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.06 0.01308
F7 SW APARTMENT 2800.79 3360.94 0.231 0.277 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 28.11 0.01308
F7 NW APARTMENT 2519.94 3023.92 0.208 0.249 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 26.58 0.01308
F7 SE APARTMENT 2565.32 3078.39 0.212 0.254 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 28.93 0.01308
F7 NE APARTMENT 1874.42 2249.30 0.155 0.185 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 25.88 0.01308
F7 N1 APARTMENT 1335.03 1602.04 0.110 0.132 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.95 0.01308
F7 N2 APARTMENT 1320.22 1584.27 0.109 0.131 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.95 0.01308
F7 S1 APARTMENT 1899.99 2279.98 0.157 0.188 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.06 0.01308
F7 S2 APARTMENT 1910.05 2292.06 0.157 0.189 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.06 0.01308
F8 SW APARTMENT 2801.16 3361.39 0.231 0.277 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 28.11 0.01308
F8 NW APARTMENT 2520.62 3024.75 0.208 0.249 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 26.58 0.01308
F8 SE APARTMENT 2567.43 3080.92 0.212 0.254 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 28.93 0.01308
F8 NE APARTMENT 1872.89 2247.47 0.154 0.185 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 25.88 0.01308
F8 N1 APARTMENT 1337.75 1605.30 0.110 0.132 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.95 0.01308
F8 N2 APARTMENT 1323.05 1587.66 0.109 0.131 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.95 0.01308
F8 S1 APARTMENT 1901.11 2281.33 0.157 0.188 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.06 0.01308
F8 S2 APARTMENT 1911.19 2293.43 0.158 0.189 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.06 0.01308
F9 SW APARTMENT 2874.73 3449.68 0.237 0.284 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 27.13 0.01308
F9 NW APARTMENT 2593.67 3112.40 0.214 0.257 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 26.58 0.01308
F9 SE APARTMENT 2623.49 3148.19 0.216 0.260 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.06 0.01308
F9 NE APARTMENT 1896.91 2276.30 0.156 0.188 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 25.88 0.01308
F9 N1 APARTMENT 1400.58 1680.70 0.115 0.139 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.95 0.01308
F9 N2 APARTMENT 1385.69 1662.83 0.114 0.137 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 24.95 0.01308
F9 S1 APARTMENT 1944.79 2333.75 0.160 0.192 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 29.20 0.01308
F9 S2 APARTMENT 1955.52 2346.62 0.161 0.193 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.06 0.01308
T SW APARTMENT 3447.32 4136.79 0.284 0.341 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 15:30:00 28.87 0.01308
T NW APARTMENT 3018.86 3622.64 0.249 0.299 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 27.13 0.01308
T SE APARTMENT 3117.63 3741.15 0.257 0.309 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 28.93 0.01308
T NE APARTMENT 2260.06 2712.08 0.186 0.224 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:45:00 26.28 0.01308
T N1 APARTMENT 1649.03 1978.83 0.136 0.163 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 15:15:00 29.04 0.01308
T N2 APARTMENT 1648.76 1978.51 0.136 0.163 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:45:00 29.20 0.01308
T S1 APARTMENT 2551.76 3062.12 0.210 0.253 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.06 0.01308
T S2 APARTMENT 2561.77 3074.13 0.211 0.253 DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 29.06 0.01308


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 3627.77 4353.33 0.170 0.204 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -28.60 0.00028
G NW APARTMENT 3634.13 4360.95 0.170 0.204 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -28.60 0.00028
OFFICE 4001.29 4801.55 0.187 0.225 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 18:45:00 -28.60 0.00028
G NE APARTMENT 3636.09 4363.31 0.170 0.204 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -28.60 0.00028
G N1 APARTMENT 2492.15 2990.58 0.117 0.140 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -28.60 0.00028
G N2 APARTMENT 2492.19 2990.62 0.117 0.140 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -28.60 0.00028
G S1 APARTMENT 2483.87 2980.64 0.116 0.140 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -28.60 0.00028
G S2 APARTMENT 2489.21 2987.05 0.117 0.140 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -28.60 0.00028
F2 SW APARTMENT 3599.59 4319.51 0.169 0.202 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F2 NW APARTMENT 3602.42 4322.90 0.169 0.202 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F2 SE APARTMENT 3612.28 4334.73 0.169 0.203 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F2 NE APARTMENT 3599.92 4319.91 0.169 0.202 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F2 N1 APARTMENT 2156.20 2587.45 0.101 0.121 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F2 N2 APARTMENT 2156.15 2587.38 0.101 0.121 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F2 S1 APARTMENT 2156.05 2587.26 0.101 0.121 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F2 S2 APARTMENT 2156.91 2588.29 0.101 0.121 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F3 SW APARTMENT 3750.32 4500.38 0.176 0.211 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F3 NW APARTMENT 3760.21 4512.25 0.176 0.211 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F3 SE APARTMENT 3746.17 4495.40 0.175 0.211 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F3 NE APARTMENT 3754.54 4505.45 0.176 0.211 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F3 N1 APARTMENT 2199.49 2639.39 0.103 0.124 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F3 N2 APARTMENT 2199.37 2639.24 0.103 0.124 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F3 S1 APARTMENT 2190.63 2628.75 0.103 0.123 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F3 S2 APARTMENT 2190.63 2628.76 0.103 0.123 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F4 SW APARTMENT 3944.91 4733.89 0.185 0.222 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F4 NW APARTMENT 3959.13 4750.95 0.185 0.223 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F4 SE APARTMENT 3937.10 4724.52 0.184 0.221 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F4 NE APARTMENT 3951.17 4741.40 0.185 0.222 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F4 N1 APARTMENT 2308.57 2770.28 0.108 0.130 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F4 N2 APARTMENT 2308.39 2770.07 0.108 0.130 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F4 S1 APARTMENT 2295.11 2754.13 0.108 0.129 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F4 S2 APARTMENT 2294.95 2753.94 0.108 0.129 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
M SW APARTMENT 4099.82 4919.79 0.192 0.230 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
M NW APARTMENT 4116.11 4939.33 0.193 0.231 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
M SE APARTMENT 4090.10 4908.12 0.192 0.230 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
M NE APARTMENT 4106.38 4927.65 0.192 0.231 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
M N1 APARTMENT 2393.11 2871.73 0.112 0.135 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
M N2 APARTMENT 2392.89 2871.47 0.112 0.135 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
M S1 APARTMENT 2377.49 2852.99 0.111 0.134 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
M S2 APARTMENT 2377.28 2852.73 0.111 0.134 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F6 SW APARTMENT 4288.14 5145.77 0.201 0.241 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F6 NW APARTMENT 4307.47 5168.96 0.202 0.242 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F6 SE APARTMENT 4276.95 5132.34 0.200 0.240 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F6 NE APARTMENT 4296.28 5155.53 0.201 0.241 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F6 N1 APARTMENT 2520.53 3024.64 0.118 0.142 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F6 N2 APARTMENT 2520.29 3024.34 0.118 0.142 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F6 S1 APARTMENT 2501.84 3002.21 0.117 0.141 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F6 S2 APARTMENT 2501.60 3001.92 0.117 0.141 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F7 SW APARTMENT 4439.84 5327.80 0.208 0.250 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F7 NW APARTMENT 4460.86 5353.03 0.209 0.251 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F7 SE APARTMENT 4427.42 5312.91 0.207 0.249 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F7 NE APARTMENT 4448.45 5338.14 0.208 0.250 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F7 N1 APARTMENT 2618.55 3142.26 0.123 0.147 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F7 N2 APARTMENT 2618.28 3141.93 0.123 0.147 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F7 S1 APARTMENT 2598.14 3117.76 0.122 0.146 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F7 S2 APARTMENT 2597.86 3117.43 0.122 0.146 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F8 SW APARTMENT 4587.23 5504.68 0.215 0.258 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F8 NW APARTMENT 4609.40 5531.28 0.216 0.259 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F8 SE APARTMENT 4573.77 5488.52 0.214 0.257 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F8 NE APARTMENT 4595.94 5515.13 0.215 0.258 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F8 N1 APARTMENT 2717.40 3260.88 0.127 0.153 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F8 N2 APARTMENT 2717.11 3260.53 0.127 0.153 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F8 S1 APARTMENT 2695.83 3235.00 0.126 0.152 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F8 S2 APARTMENT 2695.54 3234.65 0.126 0.152 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F9 SW APARTMENT 4860.89 5833.07 0.228 0.273 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F9 NW APARTMENT 4881.26 5857.51 0.229 0.274 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F9 SE APARTMENT 4846.38 5815.65 0.227 0.272 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F9 NE APARTMENT 4866.74 5840.09 0.228 0.274 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F9 N1 APARTMENT 2933.82 3520.59 0.137 0.165 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F9 N2 APARTMENT 2933.50 3520.20 0.137 0.165 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F9 S1 APARTMENT 2913.68 3496.42 0.136 0.164 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
F9 S2 APARTMENT 2913.36 3496.04 0.136 0.164 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
T SW APARTMENT 5592.53 6711.03 0.262 0.314 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
T NW APARTMENT 5619.83 6743.79 0.263 0.316 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
T SE APARTMENT 5578.29 6693.95 0.261 0.313 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
T NE APARTMENT 5605.60 6726.71 0.263 0.315 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
T N1 APARTMENT 3695.94 4435.13 0.173 0.208 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
T N2 APARTMENT 3695.60 4434.72 0.173 0.208 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
T S1 APARTMENT 3666.16 4399.40 0.172 0.206 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028
T S2 APARTMENT 3665.83 4398.99 0.172 0.206 DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -28.60 0.00028


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
AIRLOOP G SW 0.21 0.21 0.20 0.20
AIRLOOP G NW 0.18 0.18 0.20 0.20
AIRLOOP OFFICE 0.33 0.33 0.22 0.22
AIRLOOP G NE 0.13 0.13 0.20 0.20
AIRLOOP G N1 0.09 0.09 0.14 0.14
AIRLOOP G N2 0.08 0.08 0.14 0.14
AIRLOOP G S1 0.13 0.13 0.14 0.14
AIRLOOP G S2 0.14 0.14 0.14 0.14
AIRLOOP F2 SW 0.28 0.28 0.20 0.20
AIRLOOP F2 NW 0.25 0.25 0.20 0.20
AIRLOOP F2 SE 0.27 0.27 0.20 0.20
AIRLOOP F2 NE 0.18 0.18 0.20 0.20
AIRLOOP F2 N1 0.13 0.13 0.12 0.12
AIRLOOP F2 N2 0.13 0.13 0.12 0.12
AIRLOOP F2 S1 0.18 0.18 0.12 0.12
AIRLOOP F2 S2 0.19 0.19 0.12 0.12
AIRLOOP F3 SW 0.28 0.28 0.21 0.21
AIRLOOP F3 NW 0.25 0.25 0.21 0.21
AIRLOOP F3 SE 0.26 0.26 0.21 0.21
AIRLOOP F3 NE 0.19 0.19 0.21 0.21
AIRLOOP F3 N1 0.13 0.13 0.12 0.12
AIRLOOP F3 N2 0.13 0.13 0.12 0.12
AIRLOOP F3 S1 0.19 0.19 0.12 0.12
AIRLOOP F3 S2 0.19 0.19 0.12 0.12
AIRLOOP F4 SW 0.28 0.28 0.22 0.22
AIRLOOP F4 NW 0.25 0.25 0.22 0.22
AIRLOOP F4 SE 0.25 0.25 0.22 0.22
AIRLOOP F4 NE 0.19 0.19 0.22 0.22
AIRLOOP F4 N1 0.13 0.13 0.13 0.13
AIRLOOP F4 N2 0.13 0.13 0.13 0.13
AIRLOOP F4 S1 0.19 0.19 0.13 0.13
AIRLOOP F4 S2 0.19 0.19 0.13 0.13
AIRLOOP M SW 0.28 0.28 0.23 0.23
AIRLOOP M NW 0.25 0.25 0.23 0.23
AIRLOOP M SE 0.26 0.26 0.23 0.23
AIRLOOP M NE 0.19 0.19 0.23 0.23
AIRLOOP M N1 0.14 0.14 0.13 0.13
AIRLOOP M N2 0.13 0.13 0.13 0.13
AIRLOOP M S1 0.19 0.19 0.13 0.13
AIRLOOP M S2 0.19 0.19 0.13 0.13
AIRLOOP F6 SW 0.28 0.28 0.24 0.24
AIRLOOP F6 NW 0.25 0.25 0.24 0.24
AIRLOOP F6 SE 0.25 0.25 0.24 0.24
AIRLOOP F6 NE 0.19 0.19 0.24 0.24
AIRLOOP F6 N1 0.13 0.13 0.14 0.14
AIRLOOP F6 N2 0.13 0.13 0.14 0.14
AIRLOOP F6 S1 0.19 0.19 0.14 0.14
AIRLOOP F6 S2 0.19 0.19 0.14 0.14
AIRLOOP F7 SW 0.28 0.28 0.25 0.25
AIRLOOP F7 NW 0.25 0.25 0.25 0.25
AIRLOOP F7 SE 0.25 0.25 0.25 0.25
AIRLOOP F7 NE 0.19 0.19 0.25 0.25
AIRLOOP F7 N1 0.13 0.13 0.15 0.15
AIRLOOP F7 N2 0.13 0.13 0.15 0.15
AIRLOOP F7 S1 0.19 0.19 0.15 0.15
AIRLOOP F7 S2 0.19 0.19 0.15 0.15
AIRLOOP F8 SW 0.28 0.28 0.26 0.26
AIRLOOP F8 NW 0.25 0.25 0.26 0.26
AIRLOOP F8 SE 0.25 0.25 0.26 0.26
AIRLOOP F8 NE 0.19 0.19 0.26 0.26
AIRLOOP F8 N1 0.13 0.13 0.15 0.15
AIRLOOP F8 N2 0.13 0.13 0.15 0.15
AIRLOOP F8 S1 0.19 0.19 0.15 0.15
AIRLOOP F8 S2 0.19 0.19 0.15 0.15
AIRLOOP F9 SW 0.28 0.28 0.27 0.27
AIRLOOP F9 NW 0.26 0.26 0.27 0.27
AIRLOOP F9 SE 0.26 0.26 0.27 0.27
AIRLOOP F9 NE 0.19 0.19 0.27 0.27
AIRLOOP F9 N1 0.14 0.14 0.16 0.16
AIRLOOP F9 N2 0.14 0.14 0.16 0.16
AIRLOOP F9 S1 0.19 0.19 0.16 0.16
AIRLOOP F9 S2 0.19 0.19 0.16 0.16
AIRLOOP T SW 0.34 0.34 0.31 0.31
AIRLOOP T NW 0.30 0.30 0.32 0.32
AIRLOOP T SE 0.31 0.31 0.31 0.31
AIRLOOP T NE 0.22 0.22 0.32 0.32
AIRLOOP T N1 0.16 0.16 0.21 0.21
AIRLOOP T N2 0.16 0.16 0.21 0.21
AIRLOOP T S1 0.25 0.25 0.21 0.21
AIRLOOP T S2 0.25 0.25 0.21 0.21



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 3678.75 7101.75 2522.00
G NW APARTMENT 4101.25 7524.50 3307.00
OFFICE 958.00 1262.25 202.25
G NE APARTMENT 4089.00 7563.25 3306.50
G N1 APARTMENT 3303.00 7850.75 2815.75
G N2 APARTMENT 3295.00 7855.25 2812.50
G S1 APARTMENT 2785.25 7283.75 1847.50
G S2 APARTMENT 2787.25 7231.75 1806.50
F2 SW APARTMENT 3516.00 6055.25 1502.25
F2 NW APARTMENT 3897.00 6713.25 2379.75
F2 SE APARTMENT 3558.50 5824.25 1318.25
F2 NE APARTMENT 3834.50 6825.00 2425.00
F2 N1 APARTMENT 2764.75 7108.00 1633.75
F2 N2 APARTMENT 2759.50 7119.75 1639.50
F2 S1 APARTMENT 2654.50 6144.75 804.25
F2 S2 APARTMENT 2669.25 6108.50 791.00
F3 SW APARTMENT 3483.50 5938.00 1366.25
F3 NW APARTMENT 3873.25 6588.50 2241.00
F3 SE APARTMENT 3488.75 5944.50 1346.25
F3 NE APARTMENT 3792.75 6696.50 2269.50
F3 N1 APARTMENT 2697.50 6915.25 1407.75
F3 N2 APARTMENT 2692.75 6928.75 1412.75
F3 S1 APARTMENT 2699.25 5902.75 664.50
F3 S2 APARTMENT 2708.50 5893.75 663.00
F4 SW APARTMENT 3505.00 5934.00 1369.75
F4 NW APARTMENT 3910.75 6583.75 2266.75
F4 SE APARTMENT 3484.00 5983.75 1372.00
F4 NE APARTMENT 3841.00 6672.75 2288.00
F4 N1 APARTMENT 2745.00 6873.00 1407.75
F4 N2 APARTMENT 2736.00 6888.00 1411.25
F4 S1 APARTMENT 2728.50 5858.25 653.50
F4 S2 APARTMENT 2728.00 5853.50 652.25
M SW APARTMENT 3479.50 5967.75 1362.25
M NW APARTMENT 3888.50 6602.75 2253.25
M SE APARTMENT 3446.00 6022.75 1364.00
M NE APARTMENT 3837.75 6684.75 2269.75
M N1 APARTMENT 2727.25 6865.00 1372.00
M N2 APARTMENT 2720.50 6882.25 1378.50
M S1 APARTMENT 2701.00 5875.25 637.00
M S2 APARTMENT 2703.00 5878.00 637.50
F6 SW APARTMENT 3467.50 6119.50 1472.00
F6 NW APARTMENT 3888.50 6749.00 2376.00
F6 SE APARTMENT 3427.50 6173.50 1480.00
F6 NE APARTMENT 3852.75 6821.00 2398.50
F6 N1 APARTMENT 2732.75 7019.75 1507.75
F6 N2 APARTMENT 2723.50 7020.00 1506.50
F6 S1 APARTMENT 2619.50 6072.00 706.25
F6 S2 APARTMENT 2616.50 6071.75 706.50
F7 SW APARTMENT 3455.50 6236.00 1556.25
F7 NW APARTMENT 3880.75 6854.25 2455.00
F7 SE APARTMENT 3395.00 6285.00 1555.25
F7 NE APARTMENT 3862.75 6918.75 2470.00
F7 N1 APARTMENT 2737.25 7116.00 1580.25
F7 N2 APARTMENT 2731.75 7119.25 1579.50
F7 S1 APARTMENT 2577.00 6209.00 752.50
F7 S2 APARTMENT 2574.25 6209.50 753.25
F8 SW APARTMENT 3438.50 6340.25 1625.75
F8 NW APARTMENT 3876.75 6924.50 2512.25
F8 SE APARTMENT 3389.75 6367.00 1626.00
F8 NE APARTMENT 3875.50 6994.50 2530.75
F8 N1 APARTMENT 2755.25 7192.50 1643.25
F8 N2 APARTMENT 2749.25 7193.25 1644.25
F8 S1 APARTMENT 2539.25 6326.25 794.25
F8 S2 APARTMENT 2533.75 6325.75 793.50
F9 SW APARTMENT 3556.00 6434.25 1836.00
F9 NW APARTMENT 3981.50 6990.00 2668.00
F9 SE APARTMENT 3502.75 6444.50 1820.00
F9 NE APARTMENT 3964.50 7051.50 2668.00
F9 N1 APARTMENT 2947.25 7243.50 1868.50
F9 N2 APARTMENT 2937.00 7243.50 1863.00
F9 S1 APARTMENT 2620.50 6458.25 967.75
F9 S2 APARTMENT 2620.00 6456.75 967.00
T SW APARTMENT 4338.00 6707.75 2852.25
T NW APARTMENT 4634.25 7234.00 3504.50
T SE APARTMENT 4322.50 6735.75 2859.75
T NE APARTMENT 4638.25 7231.25 3508.75
T N1 APARTMENT 3932.50 7402.75 2967.00
T N2 APARTMENT 3930.00 7405.75 2967.75
T S1 APARTMENT 3596.50 6643.00 2175.25
T S2 APARTMENT 3597.75 6646.50 2175.25
G CORRIDOR 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00
Facility 5990.50 8022.25 4000.75
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 1.25 5.75 1.25 5.75
G NW APARTMENT 1.00 0.75 1.00 0.75
OFFICE 3.75 0.00 0.50 0.00
G NE APARTMENT 1.00 0.00 1.00 0.00
G N1 APARTMENT 4.75 0.00 4.75 0.00
G N2 APARTMENT 5.25 0.00 5.25 0.00
G S1 APARTMENT 2.75 1.75 2.75 1.75
G S2 APARTMENT 2.50 3.00 2.50 3.00
F2 SW APARTMENT 1.00 5.50 1.00 5.50
F2 NW APARTMENT 1.50 7.75 1.50 7.75
F2 SE APARTMENT 1.75 0.25 1.75 0.25
F2 NE APARTMENT 1.75 8.25 1.75 8.25
F2 N1 APARTMENT 4.50 33.50 4.50 33.50
F2 N2 APARTMENT 2.50 35.50 2.50 35.50
F2 S1 APARTMENT 3.00 3.75 3.00 3.75
F2 S2 APARTMENT 2.75 3.50 2.75 3.50
F3 SW APARTMENT 1.50 7.00 1.50 7.00
F3 NW APARTMENT 0.75 10.25 0.75 10.25
F3 SE APARTMENT 2.50 3.25 2.50 3.25
F3 NE APARTMENT 1.25 7.75 1.25 7.75
F3 N1 APARTMENT 3.00 39.00 3.00 39.00
F3 N2 APARTMENT 2.25 42.50 2.25 42.50
F3 S1 APARTMENT 1.25 4.50 1.25 4.50
F3 S2 APARTMENT 1.50 4.00 1.50 4.00
F4 SW APARTMENT 0.50 7.75 0.50 7.75
F4 NW APARTMENT 1.00 10.75 1.00 10.75
F4 SE APARTMENT 1.75 4.00 1.75 4.00
F4 NE APARTMENT 0.25 4.50 0.25 4.50
F4 N1 APARTMENT 2.75 41.50 2.75 41.50
F4 N2 APARTMENT 2.00 44.00 2.00 44.00
F4 S1 APARTMENT 2.75 7.25 2.75 7.25
F4 S2 APARTMENT 2.75 6.25 2.75 6.25
M SW APARTMENT 1.50 8.25 1.50 8.25
M NW APARTMENT 0.75 11.25 0.75 11.25
M SE APARTMENT 1.25 5.00 1.25 5.00
M NE APARTMENT 0.25 3.00 0.25 3.00
M N1 APARTMENT 3.50 42.25 3.50 42.25
M N2 APARTMENT 3.75 44.50 3.75 44.50
M S1 APARTMENT 2.00 8.25 2.00 8.25
M S2 APARTMENT 3.00 6.75 3.00 6.75
F6 SW APARTMENT 1.00 8.50 1.00 8.50
F6 NW APARTMENT 0.00 11.50 0.00 11.50
F6 SE APARTMENT 0.50 5.75 0.50 5.75
F6 NE APARTMENT 0.00 1.50 0.00 1.50
F6 N1 APARTMENT 3.50 30.50 3.50 30.50
F6 N2 APARTMENT 1.50 29.75 1.50 29.75
F6 S1 APARTMENT 3.00 9.00 3.00 9.00
F6 S2 APARTMENT 2.75 7.50 2.75 7.50
F7 SW APARTMENT 1.00 8.75 1.00 8.75
F7 NW APARTMENT 0.25 11.25 0.25 11.25
F7 SE APARTMENT 0.25 6.25 0.25 6.25
F7 NE APARTMENT 0.25 0.75 0.25 0.75
F7 N1 APARTMENT 2.00 21.25 2.00 21.25
F7 N2 APARTMENT 2.50 21.00 2.50 21.00
F7 S1 APARTMENT 3.75 9.75 3.75 9.75
F7 S2 APARTMENT 3.75 7.75 3.75 7.75
F8 SW APARTMENT 1.00 9.00 1.00 9.00
F8 NW APARTMENT 0.50 7.75 0.50 7.75
F8 SE APARTMENT 1.25 5.25 1.25 5.25
F8 NE APARTMENT 0.25 0.50 0.25 0.50
F8 N1 APARTMENT 1.50 17.25 1.50 17.25
F8 N2 APARTMENT 2.25 16.50 2.25 16.50
F8 S1 APARTMENT 2.25 9.25 2.25 9.25
F8 S2 APARTMENT 3.50 7.50 3.50 7.50
F9 SW APARTMENT 0.50 9.00 0.50 9.00
F9 NW APARTMENT 0.00 6.00 0.00 6.00
F9 SE APARTMENT 0.50 2.00 0.50 2.00
F9 NE APARTMENT 0.25 0.00 0.25 0.00
F9 N1 APARTMENT 1.75 11.25 1.75 11.25
F9 N2 APARTMENT 2.00 9.75 2.00 9.75
F9 S1 APARTMENT 1.50 8.50 1.50 8.50
F9 S2 APARTMENT 2.25 8.50 2.25 8.50
T SW APARTMENT 0.25 6.75 0.25 6.75
T NW APARTMENT 0.00 6.75 0.00 6.75
T SE APARTMENT 0.50 4.00 0.50 4.00
T NE APARTMENT 0.00 0.00 0.00 0.00
T N1 APARTMENT 1.25 1.00 1.25 1.00
T N2 APARTMENT 0.50 1.00 0.50 1.00
T S1 APARTMENT 1.25 1.50 1.25 1.50
T S2 APARTMENT 1.00 1.50 1.00 1.50
G CORRIDOR 0.00 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
Facility 111.75 51.75 109.00 51.75
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.353 0.215 0.000 0.259
G NW APARTMENT 1.71 2.50 268.96 0.353 0.215 0.000 0.251
OFFICE 0.94 1.00 268.96 0.519 0.241 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.353 0.215 0.000 0.252
G N1 APARTMENT 1.71 2.50 268.96 0.353 0.130 0.000 0.246
G N2 APARTMENT 1.71 2.50 268.97 0.353 0.129 0.000 0.246
G S1 APARTMENT 1.71 2.50 268.96 0.354 0.130 0.000 0.257
G S2 APARTMENT 1.71 2.50 268.97 0.354 0.130 0.000 0.257
F2 SW APARTMENT 1.71 2.50 268.96 0.354 0.309 0.000 0.304
F2 NW APARTMENT 1.71 2.50 268.96 0.353 0.309 0.000 0.292
F2 SE APARTMENT 1.71 2.50 268.96 0.354 0.309 0.000 0.305
F2 NE APARTMENT 1.71 2.50 268.96 0.353 0.309 0.000 0.292
F2 N1 APARTMENT 1.71 2.50 268.96 0.353 0.186 0.000 0.287
F2 N2 APARTMENT 1.71 2.50 268.97 0.353 0.186 0.000 0.287
F2 S1 APARTMENT 1.71 2.50 268.96 0.354 0.186 0.000 0.302
F2 S2 APARTMENT 1.71 2.50 268.97 0.354 0.186 0.000 0.302
F3 SW APARTMENT 1.71 2.50 268.96 0.354 0.366 0.000 0.330
F3 NW APARTMENT 1.71 2.50 268.96 0.353 0.366 0.000 0.317
F3 SE APARTMENT 1.71 2.50 268.96 0.354 0.366 0.000 0.331
F3 NE APARTMENT 1.71 2.50 268.96 0.353 0.365 0.000 0.317
F3 N1 APARTMENT 1.71 2.50 268.96 0.353 0.220 0.000 0.313
F3 N2 APARTMENT 1.71 2.50 268.97 0.353 0.220 0.000 0.313
F3 S1 APARTMENT 1.71 2.50 268.96 0.354 0.221 0.000 0.329
F3 S2 APARTMENT 1.71 2.50 268.97 0.354 0.221 0.000 0.329
F4 SW APARTMENT 1.71 2.50 268.96 0.353 0.409 0.000 0.337
F4 NW APARTMENT 1.71 2.50 268.96 0.353 0.408 0.000 0.323
F4 SE APARTMENT 1.71 2.50 268.96 0.353 0.409 0.000 0.337
F4 NE APARTMENT 1.71 2.50 268.96 0.353 0.408 0.000 0.323
F4 N1 APARTMENT 1.71 2.50 268.96 0.353 0.246 0.000 0.319
F4 N2 APARTMENT 1.71 2.50 268.97 0.353 0.246 0.000 0.319
F4 S1 APARTMENT 1.71 2.50 268.96 0.354 0.247 0.000 0.336
F4 S2 APARTMENT 1.71 2.50 268.97 0.354 0.247 0.000 0.336
M SW APARTMENT 1.71 2.50 268.96 0.353 0.444 0.000 0.353
M NW APARTMENT 1.71 2.50 268.96 0.353 0.444 0.000 0.338
M SE APARTMENT 1.71 2.50 268.96 0.353 0.444 0.000 0.354
M NE APARTMENT 1.71 2.50 268.96 0.353 0.444 0.000 0.338
M N1 APARTMENT 1.71 2.50 268.96 0.353 0.268 0.000 0.335
M N2 APARTMENT 1.71 2.50 268.97 0.353 0.268 0.000 0.335
M S1 APARTMENT 1.71 2.50 268.96 0.354 0.268 0.000 0.352
M S2 APARTMENT 1.71 2.50 268.97 0.354 0.268 0.000 0.352
F6 SW APARTMENT 1.71 2.50 268.96 0.353 0.474 0.000 0.367
F6 NW APARTMENT 1.71 2.50 268.96 0.353 0.474 0.000 0.351
F6 SE APARTMENT 1.71 2.50 268.96 0.353 0.474 0.000 0.368
F6 NE APARTMENT 1.71 2.50 268.96 0.353 0.474 0.000 0.351
F6 N1 APARTMENT 1.71 2.50 268.96 0.353 0.286 0.000 0.348
F6 N2 APARTMENT 1.71 2.50 268.97 0.353 0.286 0.000 0.348
F6 S1 APARTMENT 1.71 2.50 268.96 0.354 0.286 0.000 0.366
F6 S2 APARTMENT 1.71 2.50 268.97 0.354 0.286 0.000 0.366
F7 SW APARTMENT 1.71 2.50 268.96 0.353 0.501 0.000 0.379
F7 NW APARTMENT 1.71 2.50 268.96 0.353 0.501 0.000 0.361
F7 SE APARTMENT 1.71 2.50 268.96 0.353 0.501 0.000 0.379
F7 NE APARTMENT 1.71 2.50 268.96 0.353 0.501 0.000 0.362
F7 N1 APARTMENT 1.71 2.50 268.96 0.353 0.302 0.000 0.358
F7 N2 APARTMENT 1.71 2.50 268.97 0.353 0.302 0.000 0.358
F7 S1 APARTMENT 1.71 2.50 268.96 0.354 0.302 0.000 0.378
F7 S2 APARTMENT 1.71 2.50 268.97 0.354 0.302 0.000 0.378
F8 SW APARTMENT 1.71 2.50 268.96 0.353 0.526 0.000 0.391
F8 NW APARTMENT 1.71 2.50 268.96 0.353 0.525 0.000 0.372
F8 SE APARTMENT 1.71 2.50 268.96 0.353 0.526 0.000 0.391
F8 NE APARTMENT 1.71 2.50 268.96 0.353 0.525 0.000 0.373
F8 N1 APARTMENT 1.71 2.50 268.96 0.353 0.317 0.000 0.369
F8 N2 APARTMENT 1.71 2.50 268.97 0.353 0.317 0.000 0.369
F8 S1 APARTMENT 1.71 2.50 268.96 0.354 0.317 0.000 0.389
F8 S2 APARTMENT 1.71 2.50 268.97 0.354 0.317 0.000 0.390
F9 SW APARTMENT 1.71 2.50 268.96 0.353 0.548 0.000 0.402
F9 NW APARTMENT 1.71 2.50 268.96 0.353 0.547 0.000 0.382
F9 SE APARTMENT 1.71 2.50 268.96 0.353 0.548 0.000 0.402
F9 NE APARTMENT 1.71 2.50 268.96 0.353 0.547 0.000 0.383
F9 N1 APARTMENT 1.71 2.50 268.96 0.353 0.330 0.000 0.379
F9 N2 APARTMENT 1.71 2.50 268.97 0.353 0.330 0.000 0.379
F9 S1 APARTMENT 1.71 2.50 268.96 0.353 0.330 0.000 0.400
F9 S2 APARTMENT 1.71 2.50 268.97 0.353 0.330 0.000 0.400
T SW APARTMENT 1.71 2.50 268.96 0.353 0.568 0.000 0.409
T NW APARTMENT 1.71 2.50 268.96 0.353 0.568 0.000 0.389
T SE APARTMENT 1.71 2.50 268.96 0.353 0.568 0.000 0.410
T NE APARTMENT 1.71 2.50 268.96 0.353 0.568 0.000 0.391
T N1 APARTMENT 1.71 2.50 268.96 0.353 0.342 0.000 0.387
T N2 APARTMENT 1.71 2.50 268.97 0.353 0.342 0.000 0.387
T S1 APARTMENT 1.71 2.50 268.96 0.353 0.343 0.000 0.408
T S2 APARTMENT 1.71 2.50 268.97 0.353 0.343 0.000 0.408
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
OFFICE 0.94 1.00 268.96 0.500 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F2 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F2 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F3 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F3 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F4 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F4 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F6 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F6 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F7 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F7 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F8 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F8 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F9 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F9 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Surfaces by Class

Total Outdoors
Wall 420 140
Floor 90 9
Roof 90 9
Internal Mass 80 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 140 140
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 80
Conditioned Zones 80
Unconditioned Zones 10
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 4156
Defaulted Fields 814
Fields with Defaults 11184
Autosized Fields 1293
Autosizable Fields 1630
Autocalculated Fields 907
Autocalculatable Fields 1710



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 3048.54 54731.34 17-MAY-04:45 290808.57 11-JAN-12:00
Electricity:Building 1433.88 25760.85 01-JAN-03:15 70162.48 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity 296.56 6715.87 01-JAN-00:15 14401.37 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 242.55 5824.91 01-JAN-00:15 11484.27 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:OFFICE 39.38 663.42 01-JAN-00:15 2934.49 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 29.88 469.18 01-JAN-00:15 2345.88 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:G CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F2 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F2 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F3 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F3 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F4 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F4 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:M SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M CORRIDOR 32.88 1042.61 01-JAN-00:15 1042.61 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 32.88 1042.61 01-JAN-00:15 1042.61 01-JAN-00:15
Electricity:Zone:F6 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F6 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F7 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F7 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F8 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F8 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F9 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F9 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:T SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T CORRIDOR 179.47 1701.70 01-JAN-00:15 10868.20 01-JAN-07:15
InteriorLights:Electricity:Zone:T CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 54.01 890.97 01-JAN-00:15 2917.11 01-JAN-19:15
InteriorEquipment:Electricity 1137.32 19044.98 01-JAN-03:15 57142.09 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 1137.32 19044.98 01-JAN-03:15 57142.09 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 9.50 194.24 01-JAN-00:15 588.62 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T CORRIDOR 163.03 1180.40 01-JAN-00:15 10346.90 01-JAN-07:15
Fans:Electricity 631.26 20017.05 01-JAN-05:30 20017.05 01-JAN-00:15
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Electricity:HVAC 1379.81 20678.30 23-MAY-02:15 243201.16 11-JAN-12:00
ElectricityProduced:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityProduced:HVAC 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricityProduced 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 3048.54 54731.34 17-MAY-04:45 290808.57 11-JAN-12:00
ElectricityPurchased:Plant 3048.54 54731.34 17-MAY-04:45 290808.57 11-JAN-12:00
Cogeneration:ElectricityPurchased 3048.54 54731.34 17-MAY-04:45 290808.57 11-JAN-12:00
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 3048.54 54731.34 17-MAY-04:45 290808.57 11-JAN-12:00
ElectricityNet:Plant 3048.54 54731.34 17-MAY-04:45 290808.57 11-JAN-12:00
Cogeneration:ElectricityNet 3048.54 54731.34 17-MAY-04:45 290808.57 11-JAN-12:00
ExteriorLights:Electricity 162.58 0.00 01-JAN-08:15 10364.00 01-JAN-00:15
General:ExteriorLights:Electricity 162.58 0.00 01-JAN-08:15 10364.00 01-JAN-00:15
General:Fans:Electricity 631.26 20017.05 01-JAN-05:30 20017.05 01-JAN-00:15
Cooling:Electricity 144.53 0.00 01-JAN-00:15 77053.22 16-JUL-16:15
Heating:Electricity 567.85 0.00 30-MAR-16:30 222302.08 19-DEC-03:00
Electricity:Plant 72.26 36.93 13-APR-16:15 5333.81 16-JUL-16:00
HeatRejection:Electricity 6.37 0.00 01-JAN-00:15 3187.96 16-JUL-16:00
Boiler Parasitic:Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Pumps:Electricity 65.89 36.93 13-APR-16:15 2145.84 01-JAN-00:15
WIRED_LTG_ELECTRICITY 0.44 0.00 01-JAN-00:15 21.60 01-JAN-19:30
WIRED_INT_EQUIP 979.40 1018.50 01-JAN-00:15 10185.00 01-JAN-07:15


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 3524.24 2357.00 10-MAR-23:45 415921.91 09-JAN-07:30
Gas:Plant 3524.24 2357.00 10-MAR-23:45 415921.91 09-JAN-07:30
WaterSystems:Gas 1343.09 2357.00 01-JAN-00:15 88770.21 27-FEB-08:00
Water Heater:WaterSystems:Gas 1343.09 2357.00 01-JAN-00:15 88770.21 27-FEB-08:00
Heating:Gas 2181.16 0.00 10-MAR-12:45 330775.49 09-JAN-06:00
Boiler:Heating:Gas 2181.16 0.00 10-MAR-12:45 330775.49 09-JAN-06:00


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
PlantLoopCoolingDemand:Facility 594.14 0.00 01-JAN-00:15 371521.75 29-JUN-19:00
PlantLoopCoolingDemand:HVAC 594.14 0.00 01-JAN-00:15 371521.75 29-JUN-19:00
CoolingCoils:PlantLoopCoolingDemand 594.14 0.00 01-JAN-00:15 371521.75 29-JUN-19:00


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 5231.00 0.00 01-JAN-02:15 0.00 25-JUN-17:30
Water:Plant 5231.00 0.00 01-JAN-02:15 0.00 25-JUN-17:30
WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
MainsWater:Facility 5231.00 0.00 01-JAN-02:15 0.00 25-JUN-17:30
MainsWater:Plant 5231.00 0.00 01-JAN-02:15 0.00 25-JUN-17:30
WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
sub cat:WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
sub cat:WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
HeatRejection:Water 452.49 0.00 01-JAN-00:15 0.00 17-JUL-14:00
HeatRejection:MainsWater 452.49 0.00 01-JAN-00:15 0.00 17-JUL-14:00


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 2728.30 558.87 17-AUG-01:30 316021.09 09-JAN-07:15
PlantLoopHeatingDemand:Plant 1048.01 558.87 17-AUG-01:30 69924.82 25-FEB-07:45
WaterSystems:PlantLoopHeatingDemand 1048.01 558.87 17-AUG-01:30 69924.82 25-FEB-07:45
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 7255.99 4984.35 29-MAY-03:00 1130793.34 11-JAN-12:00
EnergyTransfer:Building 1902.33 2633.87 10-MAY-21:15 381169.56 11-JAN-12:00
EnergyTransfer:Zone:G SW APARTMENT 21.20 0.01 18-APR-20:45 3771.57 11-JAN-12:00
Heating:EnergyTransfer 1490.71 0.00 10-MAR-14:00 381169.56 11-JAN-12:00
Heating:EnergyTransfer:Zone:G SW APARTMENT 16.92 0.00 02-JAN-13:15 3771.57 11-JAN-12:00
Cooling:EnergyTransfer 411.62 0.00 01-JAN-00:15 168932.87 17-JUL-14:15
Cooling:EnergyTransfer:Zone:G SW APARTMENT 4.28 0.00 01-JAN-00:15 2269.24 25-AUG-16:15
EnergyTransfer:Zone:G NW APARTMENT 24.39 0.07 28-APR-23:00 3889.08 11-JAN-12:00
Heating:EnergyTransfer:Zone:G NW APARTMENT 21.76 0.00 09-FEB-16:15 3889.08 11-JAN-12:00
Cooling:EnergyTransfer:Zone:G NW APARTMENT 2.63 0.00 01-JAN-00:15 2035.85 06-JUL-17:45
EnergyTransfer:Zone:OFFICE 25.14 0.14 26-MAY-02:45 3528.71 19-DEC-03:00
Heating:EnergyTransfer:Zone:OFFICE 13.45 0.00 02-JAN-09:30 3528.71 19-DEC-03:00
Cooling:EnergyTransfer:Zone:OFFICE 11.69 0.00 01-JAN-00:15 3427.73 17-JUL-13:45
EnergyTransfer:Zone:G NE APARTMENT 23.98 0.08 31-MAR-13:30 3851.85 11-JAN-12:00
Heating:EnergyTransfer:Zone:G NE APARTMENT 21.65 0.00 10-MAR-13:30 3851.85 11-JAN-12:00
Cooling:EnergyTransfer:Zone:G NE APARTMENT 2.33 0.00 01-JAN-00:15 1667.23 26-JUN-09:30
EnergyTransfer:Zone:G N1 APARTMENT 15.61 0.00 18-AUG-18:30 2549.11 08-JAN-08:30
Heating:EnergyTransfer:Zone:G N1 APARTMENT 13.34 0.00 10-MAR-14:00 2549.11 08-JAN-08:30
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 2.26 0.00 01-JAN-00:15 1213.09 29-JUN-18:30
EnergyTransfer:Zone:G N2 APARTMENT 15.60 0.07 10-MAY-23:00 2546.65 08-JAN-08:30
Heating:EnergyTransfer:Zone:G N2 APARTMENT 13.34 0.00 10-MAR-14:00 2546.65 08-JAN-08:30
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 2.26 0.00 01-JAN-00:15 1201.44 29-JUN-18:30
EnergyTransfer:Zone:G S1 APARTMENT 12.81 0.01 28-MAY-13:45 2319.73 11-JAN-12:00
Heating:EnergyTransfer:Zone:G S1 APARTMENT 8.56 0.00 02-JAN-11:00 2319.73 11-JAN-12:00
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 4.24 0.00 01-JAN-00:15 1582.41 11-AUG-12:45
EnergyTransfer:Zone:G S2 APARTMENT 12.74 0.01 19-MAY-07:00 2278.68 11-JAN-12:00
Heating:EnergyTransfer:Zone:G S2 APARTMENT 8.31 0.00 02-JAN-11:00 2278.68 11-JAN-12:00
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 4.43 0.00 01-JAN-00:15 1583.89 11-AUG-12:45
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F2 SW APARTMENT 23.32 0.02 29-SEP-24:00 4550.58 19-DEC-03:00
Heating:EnergyTransfer:Zone:F2 SW APARTMENT 16.06 0.00 02-JAN-13:00 4550.58 19-DEC-03:00
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT 7.26 0.00 01-JAN-00:15 2964.17 25-AUG-16:15
EnergyTransfer:Zone:F2 NW APARTMENT 26.25 0.01 14-APR-20:15 4730.14 19-DEC-03:00
Heating:EnergyTransfer:Zone:F2 NW APARTMENT 21.88 0.00 09-FEB-15:30 4730.14 19-DEC-03:00
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT 4.38 0.00 01-JAN-00:15 2647.40 19-JUL-17:30
EnergyTransfer:Zone:F2 SE APARTMENT 22.82 0.06 17-AUG-20:30 4475.16 19-DEC-03:00
Heating:EnergyTransfer:Zone:F2 SE APARTMENT 14.96 0.00 02-JAN-12:15 4475.16 19-DEC-03:00
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT 7.86 0.00 01-JAN-00:15 2905.07 17-JUL-12:00
EnergyTransfer:Zone:F2 NE APARTMENT 25.91 0.20 19-SEP-02:00 4728.13 19-DEC-03:00
Heating:EnergyTransfer:Zone:F2 NE APARTMENT 21.69 0.00 10-MAR-10:15 4728.13 19-DEC-03:00
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT 4.23 0.00 01-JAN-00:15 2216.05 17-JUL-10:15
EnergyTransfer:Zone:F2 N1 APARTMENT 15.00 0.01 19-MAY-10:30 2786.02 19-DEC-03:00
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT 11.12 0.00 09-FEB-17:15 2786.02 19-DEC-03:00
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT 3.89 0.00 01-JAN-00:15 1405.85 19-JUL-17:30
EnergyTransfer:Zone:F2 N2 APARTMENT 14.99 0.06 18-SEP-10:45 2786.36 19-DEC-03:00
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT 11.12 0.00 09-FEB-17:15 2786.36 19-DEC-03:00
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT 3.88 0.00 01-JAN-00:15 1395.30 19-JUL-17:15
EnergyTransfer:Zone:F2 S1 APARTMENT 13.63 0.04 10-MAY-15:30 2591.93 19-DEC-03:00
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT 6.47 0.00 02-JAN-10:30 2591.93 19-DEC-03:00
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT 7.17 0.00 01-JAN-00:15 2045.06 11-AUG-12:45
EnergyTransfer:Zone:F2 S2 APARTMENT 13.66 0.03 21-OCT-04:30 2586.96 19-DEC-03:00
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT 6.42 0.00 02-JAN-10:30 2586.96 19-DEC-03:00
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT 7.25 0.00 01-JAN-00:15 2071.53 11-AUG-12:45
EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F3 SW APARTMENT 24.74 0.00 23-AUG-03:15 5067.16 11-JAN-12:00
Heating:EnergyTransfer:Zone:F3 SW APARTMENT 17.18 0.00 02-JAN-13:15 5067.16 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT 7.56 0.00 01-JAN-00:15 3109.01 18-MAY-18:00
EnergyTransfer:Zone:F3 NW APARTMENT 27.77 0.04 22-SEP-12:45 5194.65 11-JAN-12:00
Heating:EnergyTransfer:Zone:F3 NW APARTMENT 23.11 0.00 09-FEB-15:30 5194.65 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT 4.66 0.00 01-JAN-00:15 2814.58 18-MAY-18:00
EnergyTransfer:Zone:F3 SE APARTMENT 24.26 0.16 09-OCT-18:15 5015.50 11-JAN-12:00
Heating:EnergyTransfer:Zone:F3 SE APARTMENT 16.88 0.00 02-JAN-13:15 5015.50 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT 7.38 0.00 01-JAN-00:15 2852.79 17-JUL-12:00
EnergyTransfer:Zone:F3 NE APARTMENT 27.40 0.12 19-SEP-03:30 5181.80 19-DEC-03:00
Heating:EnergyTransfer:Zone:F3 NE APARTMENT 22.93 0.00 10-MAR-10:15 5181.80 19-DEC-03:00
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT 4.47 0.00 01-JAN-00:15 2297.33 17-JUL-09:45
EnergyTransfer:Zone:F3 N1 APARTMENT 15.60 0.02 24-JUL-13:00 3017.47 19-DEC-03:00
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT 11.34 0.00 09-FEB-16:30 3017.47 19-DEC-03:00
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT 4.26 0.00 01-JAN-00:15 1475.13 19-JUL-17:15
EnergyTransfer:Zone:F3 N2 APARTMENT 15.59 0.00 21-MAY-15:00 3017.72 19-DEC-03:00
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT 11.34 0.00 09-FEB-16:30 3017.72 19-DEC-03:00
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT 4.25 0.00 01-JAN-00:15 1464.47 19-JUL-17:15
EnergyTransfer:Zone:F3 S1 APARTMENT 14.45 0.02 28-APR-14:00 2863.42 11-JAN-12:00
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT 6.68 0.00 02-JAN-10:30 2863.42 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT 7.78 0.00 01-JAN-00:15 2114.35 19-JUL-14:00
EnergyTransfer:Zone:F3 S2 APARTMENT 14.46 0.00 11-JUL-18:45 2861.41 11-JAN-12:00
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT 6.67 0.00 02-JAN-10:30 2861.41 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT 7.79 0.00 01-JAN-00:15 2122.81 19-JUL-14:00
EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F4 SW APARTMENT 26.15 0.04 26-SEP-14:15 5535.23 11-JAN-12:00
Heating:EnergyTransfer:Zone:F4 SW APARTMENT 18.75 0.00 02-JAN-13:45 5535.23 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT 7.40 0.00 01-JAN-00:15 3162.33 18-MAY-18:00
EnergyTransfer:Zone:F4 NW APARTMENT 29.42 0.01 15-JUN-02:30 5662.05 11-JAN-12:00
Heating:EnergyTransfer:Zone:F4 NW APARTMENT 24.80 0.00 09-FEB-16:15 5662.05 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT 4.63 0.00 01-JAN-00:15 2877.04 18-MAY-18:00
EnergyTransfer:Zone:F4 SE APARTMENT 25.65 0.01 10-SEP-10:45 5489.06 11-JAN-12:00
Heating:EnergyTransfer:Zone:F4 SE APARTMENT 18.57 0.00 20-JAN-11:45 5489.06 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT 7.09 0.00 01-JAN-00:15 2873.70 17-JUL-11:45
EnergyTransfer:Zone:F4 NE APARTMENT 29.01 0.06 21-APR-11:00 5614.42 11-JAN-12:00
Heating:EnergyTransfer:Zone:F4 NE APARTMENT 24.62 0.00 10-MAR-10:30 5614.42 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT 4.39 0.00 01-JAN-00:15 2298.11 17-JUL-09:15
EnergyTransfer:Zone:F4 N1 APARTMENT 16.47 0.00 29-APR-06:30 3265.61 11-JAN-12:00
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT 12.17 0.00 09-FEB-16:30 3265.61 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT 4.31 0.00 01-JAN-00:15 1513.67 18-MAY-18:00
EnergyTransfer:Zone:F4 N2 APARTMENT 16.46 0.01 19-SEP-09:30 3264.33 11-JAN-12:00
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT 12.17 0.00 09-FEB-16:30 3264.33 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT 4.30 0.00 01-JAN-00:15 1493.48 18-MAY-18:00
EnergyTransfer:Zone:F4 S1 APARTMENT 15.12 0.04 20-JUN-08:15 3135.93 11-JAN-12:00
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT 7.38 0.00 02-JAN-10:45 3135.93 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT 7.75 0.00 01-JAN-00:15 2155.35 19-JUL-14:00
EnergyTransfer:Zone:F4 S2 APARTMENT 15.11 0.03 17-JUN-09:45 3134.54 11-JAN-12:00
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT 7.37 0.00 02-JAN-10:45 3134.54 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT 7.73 0.00 01-JAN-00:15 2162.91 19-JUL-14:00
EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M SW APARTMENT 27.25 0.04 10-SEP-22:45 5913.23 11-JAN-12:00
Heating:EnergyTransfer:Zone:M SW APARTMENT 20.04 0.00 02-JAN-14:15 5913.23 11-JAN-12:00
Cooling:EnergyTransfer:Zone:M SW APARTMENT 7.22 0.00 01-JAN-00:15 3205.91 18-MAY-18:00
EnergyTransfer:Zone:M NW APARTMENT 30.71 0.07 01-OCT-19:15 6037.69 11-JAN-12:00
Heating:EnergyTransfer:Zone:M NW APARTMENT 26.13 0.00 09-FEB-16:15 6037.69 11-JAN-12:00
Cooling:EnergyTransfer:Zone:M NW APARTMENT 4.57 0.00 01-JAN-00:15 2921.77 18-MAY-18:00
EnergyTransfer:Zone:M SE APARTMENT 26.75 0.06 08-AUG-02:15 5867.16 11-JAN-12:00
Heating:EnergyTransfer:Zone:M SE APARTMENT 19.87 0.00 20-JAN-12:00 5867.16 11-JAN-12:00
Cooling:EnergyTransfer:Zone:M SE APARTMENT 6.88 0.00 01-JAN-00:15 2915.63 17-JUL-11:45
EnergyTransfer:Zone:M NE APARTMENT 30.27 0.04 02-MAY-17:00 5989.45 11-JAN-12:00
Heating:EnergyTransfer:Zone:M NE APARTMENT 25.95 0.00 10-MAR-10:45 5989.45 11-JAN-12:00
Cooling:EnergyTransfer:Zone:M NE APARTMENT 4.32 0.00 01-JAN-00:15 2315.39 17-JUL-09:15
EnergyTransfer:Zone:M N1 APARTMENT 17.13 0.01 29-JUL-16:45 3482.96 11-JAN-12:00
Heating:EnergyTransfer:Zone:M N1 APARTMENT 12.81 0.00 09-FEB-16:30 3482.96 11-JAN-12:00
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 4.33 0.00 01-JAN-00:15 1564.53 18-MAY-18:00
EnergyTransfer:Zone:M N2 APARTMENT 17.11 0.00 14-SEP-17:00 3481.68 11-JAN-12:00
Heating:EnergyTransfer:Zone:M N2 APARTMENT 12.80 0.00 09-FEB-16:30 3481.68 11-JAN-12:00
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 4.31 0.00 01-JAN-00:15 1544.71 18-MAY-18:00
EnergyTransfer:Zone:M S1 APARTMENT 15.59 0.06 20-JUL-10:00 3355.67 11-JAN-12:00
Heating:EnergyTransfer:Zone:M S1 APARTMENT 7.96 0.00 02-JAN-10:45 3355.67 11-JAN-12:00
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 7.64 0.00 01-JAN-00:15 2204.86 19-JUL-14:00
EnergyTransfer:Zone:M S2 APARTMENT 15.58 0.00 21-MAY-13:30 3354.38 11-JAN-12:00
Heating:EnergyTransfer:Zone:M S2 APARTMENT 7.96 0.00 02-JAN-10:45 3354.38 11-JAN-12:00
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 7.62 0.00 01-JAN-00:15 2212.30 19-JUL-14:00
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F6 SW APARTMENT 28.45 0.08 28-JUL-08:30 6290.25 11-JAN-12:00
Heating:EnergyTransfer:Zone:F6 SW APARTMENT 21.88 0.00 29-JAN-14:45 6290.25 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT 6.57 0.00 01-JAN-00:15 3180.06 18-MAY-18:00
EnergyTransfer:Zone:F6 NW APARTMENT 32.31 0.02 03-OCT-14:00 6414.50 11-JAN-12:00
Heating:EnergyTransfer:Zone:F6 NW APARTMENT 28.15 0.00 09-FEB-16:15 6414.50 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT 4.16 0.00 01-JAN-00:15 2888.82 18-MAY-18:00
EnergyTransfer:Zone:F6 SE APARTMENT 27.96 0.01 12-AUG-18:00 6243.64 11-JAN-12:00
Heating:EnergyTransfer:Zone:F6 SE APARTMENT 21.71 0.00 01-FEB-12:15 6243.64 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT 6.25 0.00 01-JAN-00:15 2895.29 17-JUL-11:45
EnergyTransfer:Zone:F6 NE APARTMENT 31.86 0.05 26-SEP-15:45 6365.57 11-JAN-12:00
Heating:EnergyTransfer:Zone:F6 NE APARTMENT 27.99 0.00 10-MAR-11:00 6365.57 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT 3.87 0.00 01-JAN-00:15 2333.27 17-JUL-07:45
EnergyTransfer:Zone:F6 N1 APARTMENT 18.00 0.03 07-JUN-18:45 3721.45 11-JAN-12:00
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT 14.10 0.00 09-FEB-17:00 3721.45 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT 3.90 0.00 01-JAN-00:15 1538.18 18-MAY-18:00
EnergyTransfer:Zone:F6 N2 APARTMENT 17.98 0.01 23-AUG-12:30 3720.15 11-JAN-12:00
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT 14.10 0.00 09-FEB-17:00 3720.15 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT 3.88 0.00 01-JAN-00:15 1519.11 18-MAY-18:00
EnergyTransfer:Zone:F6 S1 APARTMENT 15.91 0.00 02-OCT-14:45 3594.24 11-JAN-12:00
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT 8.97 0.00 02-JAN-11:00 3594.24 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT 6.94 0.00 01-JAN-00:15 2190.73 19-JUL-14:00
EnergyTransfer:Zone:F6 S2 APARTMENT 15.89 0.10 31-JAN-18:00 3592.96 11-JAN-12:00
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT 8.97 0.00 02-JAN-11:00 3592.96 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT 6.92 0.00 01-JAN-00:15 2198.21 19-JUL-14:00
EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F7 SW APARTMENT 29.53 0.00 03-JUL-15:45 6610.35 11-JAN-12:00
Heating:EnergyTransfer:Zone:F7 SW APARTMENT 23.39 0.00 01-FEB-12:30 6610.35 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT 6.13 0.00 01-JAN-00:15 3170.86 18-MAY-18:00
EnergyTransfer:Zone:F7 NW APARTMENT 33.64 0.01 15-JUN-01:30 6733.10 11-JAN-12:00
Heating:EnergyTransfer:Zone:F7 NW APARTMENT 29.75 0.00 09-FEB-16:30 6733.10 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT 3.90 0.00 01-JAN-00:15 2874.44 18-MAY-18:00
EnergyTransfer:Zone:F7 SE APARTMENT 29.04 0.00 17-AUG-04:45 6563.35 11-JAN-12:00
Heating:EnergyTransfer:Zone:F7 SE APARTMENT 23.21 0.00 01-FEB-12:30 6563.35 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT 5.82 0.00 01-JAN-00:15 2894.01 17-JUL-11:45
EnergyTransfer:Zone:F7 NE APARTMENT 33.18 0.03 03-JUN-15:30 6683.68 11-JAN-12:00
Heating:EnergyTransfer:Zone:F7 NE APARTMENT 29.60 0.00 10-MAR-12:45 6683.68 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT 3.59 0.00 01-JAN-00:15 2341.21 17-JUL-07:45
EnergyTransfer:Zone:F7 N1 APARTMENT 18.73 0.00 05-NOV-05:15 3918.98 11-JAN-12:00
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT 15.10 0.00 09-FEB-17:15 3918.98 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT 3.63 0.00 01-JAN-00:15 1556.21 26-MAY-15:45
EnergyTransfer:Zone:F7 N2 APARTMENT 18.72 0.06 17-JUN-11:00 3917.68 11-JAN-12:00
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT 15.10 0.00 09-FEB-17:15 3917.68 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT 3.62 0.00 01-JAN-00:15 1555.37 26-MAY-15:45
EnergyTransfer:Zone:F7 S1 APARTMENT 16.27 0.14 26-NOV-15:30 3793.73 11-JAN-12:00
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT 9.80 0.00 02-JAN-11:15 3793.73 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT 6.46 0.00 01-JAN-00:15 2194.35 19-JUL-14:00
EnergyTransfer:Zone:F7 S2 APARTMENT 16.25 0.05 11-OCT-14:00 3792.45 11-JAN-12:00
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT 9.80 0.00 02-JAN-11:15 3792.45 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT 6.45 0.00 01-JAN-00:15 2201.88 19-JUL-14:00
EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F8 SW APARTMENT 30.62 0.02 11-SEP-06:45 6904.65 11-JAN-12:00
Heating:EnergyTransfer:Zone:F8 SW APARTMENT 24.83 0.00 01-FEB-12:45 6904.65 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT 5.79 0.00 01-JAN-00:15 3169.04 18-MAY-18:00
EnergyTransfer:Zone:F8 NW APARTMENT 34.96 0.02 12-SEP-13:45 7025.15 11-JAN-12:00
Heating:EnergyTransfer:Zone:F8 NW APARTMENT 31.28 0.00 09-FEB-16:30 7025.15 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT 3.68 0.00 01-JAN-00:15 2872.97 18-MAY-18:00
EnergyTransfer:Zone:F8 SE APARTMENT 30.14 0.00 10-OCT-01:30 6857.35 11-JAN-12:00
Heating:EnergyTransfer:Zone:F8 SE APARTMENT 24.65 0.00 01-FEB-12:30 6857.35 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT 5.48 0.00 01-JAN-00:15 2923.67 17-JUL-12:00
EnergyTransfer:Zone:F8 NE APARTMENT 34.50 0.00 10-SEP-17:00 6975.41 11-JAN-12:00
Heating:EnergyTransfer:Zone:F8 NE APARTMENT 31.12 0.00 10-MAR-13:00 6975.41 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT 3.38 0.00 01-JAN-00:15 2362.37 17-JUL-19:00
EnergyTransfer:Zone:F8 N1 APARTMENT 19.50 0.00 27-AUG-16:00 4102.07 11-JAN-12:00
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT 16.07 0.00 09-FEB-17:15 4102.07 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT 3.43 0.00 01-JAN-00:15 1620.61 28-JUN-18:15
EnergyTransfer:Zone:F8 N2 APARTMENT 19.49 0.00 12-AUG-05:45 4100.78 11-JAN-12:00
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT 16.07 0.00 11-FEB-20:15 4100.78 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT 3.42 0.00 01-JAN-00:15 1620.84 28-JUN-18:15
EnergyTransfer:Zone:F8 S1 APARTMENT 16.72 0.05 05-APR-07:00 3980.00 11-JAN-12:00
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT 10.63 0.00 02-JAN-11:30 3980.00 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT 6.08 0.00 01-JAN-00:15 2205.14 19-JUL-14:00
EnergyTransfer:Zone:F8 S2 APARTMENT 16.70 0.06 28-AUG-20:45 3978.74 11-JAN-12:00
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT 10.63 0.00 02-JAN-11:30 3978.74 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT 6.07 0.00 01-JAN-00:15 2212.75 19-JUL-14:00
EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F9 SW APARTMENT 32.68 0.03 16-SEP-01:30 7259.87 11-JAN-12:00
Heating:EnergyTransfer:Zone:F9 SW APARTMENT 27.17 0.00 01-FEB-12:45 7259.87 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT 5.51 0.00 01-JAN-00:15 3311.15 18-MAY-17:45
EnergyTransfer:Zone:F9 NW APARTMENT 37.30 0.00 13-AUG-04:45 7377.42 11-JAN-12:00
Heating:EnergyTransfer:Zone:F9 NW APARTMENT 33.77 0.00 09-FEB-17:00 7377.42 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT 3.54 0.00 01-JAN-00:15 2973.07 18-MAY-17:45
EnergyTransfer:Zone:F9 SE APARTMENT 32.16 0.00 28-AUG-09:15 7210.53 11-JAN-12:00
Heating:EnergyTransfer:Zone:F9 SE APARTMENT 27.00 0.00 01-FEB-12:30 7210.53 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT 5.16 0.00 01-JAN-00:15 3005.62 17-JUL-12:00
EnergyTransfer:Zone:F9 NE APARTMENT 36.83 0.01 15-MAY-17:00 7325.57 11-JAN-12:00
Heating:EnergyTransfer:Zone:F9 NE APARTMENT 33.59 0.00 10-MAR-13:15 7325.57 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT 3.24 0.00 01-JAN-00:15 2470.63 17-JUL-18:45
EnergyTransfer:Zone:F9 N1 APARTMENT 21.18 0.01 11-JUN-19:00 4347.02 11-JAN-12:00
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT 17.93 0.00 11-FEB-20:00 4347.02 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT 3.25 0.00 01-JAN-00:15 1743.81 28-JUN-18:15
EnergyTransfer:Zone:F9 N2 APARTMENT 21.17 0.00 26-MAY-10:00 4345.66 11-JAN-12:00
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT 17.92 0.00 11-FEB-20:30 4345.66 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT 3.25 0.00 01-JAN-00:15 1744.01 28-JUN-18:15
EnergyTransfer:Zone:F9 S1 APARTMENT 17.88 0.00 26-JUL-11:00 4229.09 11-JAN-12:00
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT 12.20 0.00 02-JAN-11:45 4229.09 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT 5.68 0.00 01-JAN-00:15 2252.28 19-JUL-14:00
EnergyTransfer:Zone:F9 S2 APARTMENT 17.87 0.00 05-SEP-15:30 4227.77 11-JAN-12:00
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT 12.21 0.00 02-JAN-11:45 4227.77 11-JAN-12:00
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT 5.66 0.00 01-JAN-00:15 2261.07 19-JUL-14:00
EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:T SW APARTMENT 41.15 0.00 05-SEP-08:30 8003.30 11-JAN-12:00
Heating:EnergyTransfer:Zone:T SW APARTMENT 35.41 0.00 01-FEB-12:30 8003.30 11-JAN-12:00
Cooling:EnergyTransfer:Zone:T SW APARTMENT 5.74 0.00 01-JAN-00:15 3784.65 17-JUL-14:15
EnergyTransfer:Zone:T NW APARTMENT 44.81 0.02 29-SEP-10:45 8127.20 11-JAN-12:00
Heating:EnergyTransfer:Zone:T NW APARTMENT 41.05 0.00 09-FEB-15:15 8127.20 11-JAN-12:00
Cooling:EnergyTransfer:Zone:T NW APARTMENT 3.76 0.00 01-JAN-00:15 3508.77 18-MAY-17:45
EnergyTransfer:Zone:T SE APARTMENT 40.29 0.03 21-JUN-01:45 7966.53 19-DEC-03:00
Heating:EnergyTransfer:Zone:T SE APARTMENT 35.06 0.00 01-FEB-12:30 7966.53 19-DEC-03:00
Cooling:EnergyTransfer:Zone:T SE APARTMENT 5.23 0.00 01-JAN-00:15 3678.94 17-JUL-11:30
EnergyTransfer:Zone:T NE APARTMENT 44.14 0.04 02-JUN-14:15 8073.71 11-JAN-12:00
Heating:EnergyTransfer:Zone:T NE APARTMENT 40.82 0.00 10-MAR-10:45 8073.71 11-JAN-12:00
Cooling:EnergyTransfer:Zone:T NE APARTMENT 3.32 0.00 01-JAN-00:15 2930.75 17-JUL-10:15
EnergyTransfer:Zone:T N1 APARTMENT 27.44 0.02 20-APR-11:15 5118.62 19-DEC-03:00
Heating:EnergyTransfer:Zone:T N1 APARTMENT 24.44 0.00 10-MAR-11:45 5118.62 19-DEC-03:00
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 3.00 0.00 01-JAN-00:15 2255.43 28-JUN-18:15
EnergyTransfer:Zone:T N2 APARTMENT 27.43 0.03 12-AUG-11:00 5118.45 19-DEC-03:00
Heating:EnergyTransfer:Zone:T N2 APARTMENT 24.44 0.00 10-MAR-11:15 5118.45 19-DEC-03:00
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 2.99 0.00 01-JAN-00:15 2250.75 28-JUN-18:15
EnergyTransfer:Zone:T S1 APARTMENT 24.25 0.00 07-AUG-05:00 5004.22 19-DEC-03:00
Heating:EnergyTransfer:Zone:T S1 APARTMENT 19.14 0.00 02-JAN-11:45 5004.22 19-DEC-03:00
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 5.11 0.00 01-JAN-00:15 2950.21 17-JUL-14:00
EnergyTransfer:Zone:T S2 APARTMENT 24.24 0.00 11-SEP-03:45 5003.98 19-DEC-03:00
Heating:EnergyTransfer:Zone:T S2 APARTMENT 19.14 0.00 02-JAN-11:45 5003.98 19-DEC-03:00
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 5.10 0.00 01-JAN-00:15 2954.71 17-JUL-14:00
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Plant 2683.12 558.87 17-AUG-01:30 314776.60 09-JAN-07:15
WaterSystems:EnergyTransfer 1048.00 558.87 17-AUG-01:30 69917.67 25-FEB-07:45
sub cat:WaterSystems:EnergyTransfer 1048.00 558.87 17-AUG-01:30 69917.67 25-FEB-07:45
EnergyTransfer:HVAC 2670.54 0.00 13-APR-16:15 468537.47 19-DEC-03:00
CoolingCoils:EnergyTransfer 464.22 0.00 01-JAN-00:15 294775.49 29-JUN-19:00
HeatingCoils:EnergyTransfer 2206.31 0.00 30-MAR-16:30 468537.47 19-DEC-03:00
PlantLoopHeatingDemand:HVAC 1680.29 0.00 30-MAR-16:30 249498.71 09-JAN-06:00
HeatingCoils:PlantLoopHeatingDemand 1680.29 0.00 30-MAR-16:30 249498.71 09-JAN-06:00
Boilers:EnergyTransfer 1635.12 0.00 10-MAR-12:45 248081.62 09-JAN-06:00



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 16.924 -4.276 0.000 0.000 3.915 1.087 12.213 17.448 0.000 0.070 0.000 0.000 -14.931 0.000 -14.439 -18.012
G NW APARTMENT 21.758 -2.634 0.000 0.000 3.935 1.087 12.213 8.166 0.000 0.070 0.000 0.000 -16.053 0.000 -14.105 -14.436
OFFICE 13.448 -11.695 0.000 0.000 0.540 29.882 9.495 16.893 0.000 0.034 0.000 0.000 -14.944 0.000 -11.438 -32.216
G NE APARTMENT 21.654 -2.330 0.000 0.000 3.942 1.087 12.213 7.613 0.000 0.070 0.000 0.000 -15.797 0.000 -14.142 -14.309
G N1 APARTMENT 13.343 -2.265 0.000 0.000 3.946 1.087 12.213 2.624 0.000 0.056 0.000 0.000 -10.173 0.000 -9.421 -11.409
G N2 APARTMENT 13.343 -2.256 0.000 0.000 3.947 1.087 12.213 2.623 0.000 0.056 0.000 0.000 -10.171 0.000 -9.422 -11.419
G S1 APARTMENT 8.561 -4.245 0.000 0.000 3.917 1.087 12.213 12.061 0.000 0.057 0.000 0.000 -9.108 0.000 -9.808 -14.733
G S2 APARTMENT 8.310 -4.434 0.000 0.000 3.913 1.087 12.213 12.044 0.000 0.056 0.000 0.000 -9.122 0.000 -9.850 -14.219
F2 SW APARTMENT 16.062 -7.259 0.000 0.000 3.864 1.087 12.213 16.775 0.000 0.093 0.000 0.000 -15.782 0.000 -20.245 -6.808
F2 NW APARTMENT 21.876 -4.378 0.000 0.000 3.900 1.087 12.213 7.750 0.000 0.092 0.000 0.000 -16.918 0.000 -19.758 -5.864
F2 SE APARTMENT 14.960 -7.859 0.000 0.000 3.858 1.087 12.213 16.252 0.000 0.093 0.000 0.000 -15.690 0.000 -20.395 -4.517
F2 NE APARTMENT 21.685 -4.227 0.000 0.000 3.913 1.087 12.213 7.219 0.000 0.091 0.000 0.000 -16.617 0.000 -19.727 -5.636
F2 N1 APARTMENT 11.115 -3.885 0.000 0.000 3.914 1.087 12.213 2.418 0.000 0.070 0.000 0.000 -10.763 0.000 -13.026 -3.143
F2 N2 APARTMENT 11.115 -3.876 0.000 0.000 3.915 1.087 12.213 2.418 0.000 0.070 0.000 0.000 -10.759 0.000 -13.021 -3.160
F2 S1 APARTMENT 6.466 -7.167 0.000 0.000 3.859 1.087 12.213 11.634 0.000 0.073 0.000 0.000 -9.627 0.000 -13.635 -4.903
F2 S2 APARTMENT 6.415 -7.248 0.000 0.000 3.857 1.087 12.213 11.629 0.000 0.073 0.000 0.000 -9.632 0.000 -13.651 -4.741
F3 SW APARTMENT 17.179 -7.560 0.000 0.000 3.861 1.087 12.213 16.513 0.000 0.114 0.000 0.000 -16.057 0.000 -23.560 -3.789
F3 NW APARTMENT 23.108 -4.664 0.000 0.000 3.896 1.087 12.213 7.604 0.000 0.112 0.000 0.000 -17.230 0.000 -23.018 -3.108
F3 SE APARTMENT 16.879 -7.382 0.000 0.000 3.864 1.087 12.213 16.049 0.000 0.114 0.000 0.000 -15.870 0.000 -23.607 -3.347
F3 NE APARTMENT 22.924 -4.471 0.000 0.000 3.908 1.087 12.213 7.081 0.000 0.112 0.000 0.000 -16.917 0.000 -22.986 -2.951
F3 N1 APARTMENT 11.339 -4.261 0.000 0.000 3.906 1.087 12.213 2.352 0.000 0.086 0.000 0.000 -10.974 0.000 -15.108 -0.639
F3 N2 APARTMENT 11.338 -4.249 0.000 0.000 3.907 1.087 12.213 2.352 0.000 0.086 0.000 0.000 -10.971 0.000 -15.103 -0.660
F3 S1 APARTMENT 6.676 -7.775 0.000 0.000 3.849 1.087 12.213 11.458 0.000 0.091 0.000 0.000 -9.812 0.000 -15.778 -2.008
F3 S2 APARTMENT 6.671 -7.789 0.000 0.000 3.848 1.087 12.213 11.455 0.000 0.091 0.000 0.000 -9.812 0.000 -15.784 -1.979
F4 SW APARTMENT 18.746 -7.402 0.000 0.000 3.863 1.087 12.213 16.353 0.000 0.124 0.000 0.000 -16.201 0.000 -25.776 -3.005
F4 NW APARTMENT 24.798 -4.626 0.000 0.000 3.897 1.087 12.213 7.522 0.000 0.122 0.000 0.000 -17.408 0.000 -25.212 -2.392
F4 SE APARTMENT 18.565 -7.087 0.000 0.000 3.869 1.087 12.213 15.906 0.000 0.124 0.000 0.000 -15.992 0.000 -25.806 -2.878
F4 NE APARTMENT 24.619 -4.390 0.000 0.000 3.908 1.087 12.213 7.002 0.000 0.122 0.000 0.000 -17.089 0.000 -25.195 -2.276
F4 N1 APARTMENT 12.165 -4.309 0.000 0.000 3.905 1.087 12.213 2.317 0.000 0.093 0.039 0.000 -11.094 0.000 -16.416 -0.000
F4 N2 APARTMENT 12.165 -4.298 0.000 0.000 3.906 1.087 12.213 2.317 0.000 0.092 0.020 0.000 -11.091 0.000 -16.411 -0.000
F4 S1 APARTMENT 7.376 -7.745 0.000 0.000 3.848 1.087 12.213 11.351 0.000 0.098 0.000 0.000 -9.905 0.000 -17.103 -1.219
F4 S2 APARTMENT 7.373 -7.733 0.000 0.000 3.848 1.087 12.213 11.349 0.000 0.098 0.000 0.000 -9.904 0.000 -17.106 -1.224
M SW APARTMENT 20.037 -7.217 0.000 0.000 3.866 1.087 12.213 16.233 0.000 0.132 0.000 0.000 -16.315 0.000 -27.819 -2.216
M NW APARTMENT 26.134 -4.574 0.000 0.000 3.900 1.087 12.213 7.463 0.000 0.130 0.000 0.000 -17.549 0.000 -27.221 -1.582
M SE APARTMENT 19.869 -6.881 0.000 0.000 3.872 1.087 12.213 15.793 0.000 0.131 0.000 0.000 -16.096 0.000 -27.844 -2.143
M NE APARTMENT 25.949 -4.323 0.000 0.000 3.909 1.087 12.213 6.944 0.000 0.130 0.000 0.000 -17.226 0.000 -27.211 -1.471
M N1 APARTMENT 12.807 -4.325 0.000 0.000 3.906 1.087 12.213 2.293 0.000 0.098 0.796 0.000 -11.189 0.000 -17.685 -0.000
M N2 APARTMENT 12.801 -4.313 0.000 0.000 3.906 1.087 12.213 2.293 0.000 0.098 0.782 0.000 -11.186 0.000 -17.681 -0.000
M S1 APARTMENT 7.955 -7.637 0.000 0.000 3.850 1.087 12.213 11.271 0.000 0.104 0.001 0.000 -9.976 0.000 -18.404 -0.461
M S2 APARTMENT 7.956 -7.620 0.000 0.000 3.850 1.087 12.213 11.270 0.000 0.104 0.001 0.000 -9.974 0.000 -18.407 -0.478
F6 SW APARTMENT 21.884 -6.567 0.000 0.000 3.874 1.087 12.213 16.168 0.000 0.138 0.000 0.000 -16.350 0.000 -29.510 -2.936
F6 NW APARTMENT 28.150 -4.164 0.000 0.000 3.908 1.087 12.213 7.444 0.000 0.136 0.000 0.000 -17.606 0.000 -28.869 -2.299
F6 SE APARTMENT 21.710 -6.245 0.000 0.000 3.881 1.087 12.213 15.733 0.000 0.137 0.000 0.000 -16.126 0.000 -29.531 -2.860
F6 NE APARTMENT 27.984 -3.871 0.000 0.000 3.916 1.087 12.213 6.925 0.000 0.137 0.000 0.000 -17.281 0.000 -28.878 -2.231
F6 N1 APARTMENT 14.103 -3.899 0.000 0.000 3.913 1.087 12.213 2.291 0.000 0.104 0.115 0.000 -11.225 0.000 -18.702 -0.000
F6 N2 APARTMENT 14.100 -3.881 0.000 0.000 3.914 1.087 12.213 2.291 0.000 0.104 0.096 0.000 -11.223 0.000 -18.701 -0.000
F6 S1 APARTMENT 8.971 -6.936 0.000 0.000 3.860 1.087 12.213 11.228 0.000 0.108 0.000 0.000 -9.993 0.000 -19.449 -1.087
F6 S2 APARTMENT 8.972 -6.918 0.000 0.000 3.860 1.087 12.213 11.226 0.000 0.108 0.000 0.000 -9.991 0.000 -19.451 -1.105
F7 SW APARTMENT 23.394 -6.133 0.000 0.000 3.881 1.087 12.213 16.107 0.000 0.143 0.000 0.000 -16.392 0.000 -31.002 -3.298
F7 NW APARTMENT 29.746 -3.898 0.000 0.000 3.914 1.087 12.213 7.423 0.000 0.141 0.000 0.000 -17.667 0.000 -30.331 -2.627
F7 SE APARTMENT 23.213 -5.824 0.000 0.000 3.888 1.087 12.213 15.676 0.000 0.143 0.000 0.000 -16.163 0.000 -31.019 -3.214
F7 NE APARTMENT 29.595 -3.585 0.000 0.000 3.921 1.087 12.213 6.904 0.000 0.143 0.000 0.000 -17.341 0.000 -30.354 -2.581
F7 N1 APARTMENT 15.099 -3.627 0.000 0.000 3.919 1.087 12.213 2.287 0.000 0.109 0.000 0.000 -11.264 0.000 -19.603 -0.219
F7 N2 APARTMENT 15.101 -3.618 0.000 0.000 3.919 1.087 12.213 2.286 0.000 0.109 0.000 0.000 -11.262 0.000 -19.602 -0.233
F7 S1 APARTMENT 9.802 -6.465 0.000 0.000 3.867 1.087 12.213 11.188 0.000 0.112 0.000 0.000 -10.015 0.000 -20.369 -1.420
F7 S2 APARTMENT 9.803 -6.446 0.000 0.000 3.868 1.087 12.213 11.186 0.000 0.112 0.000 0.000 -10.012 0.000 -20.371 -1.439
F8 SW APARTMENT 24.834 -5.788 0.000 0.000 3.886 1.087 12.213 16.054 0.000 0.148 0.000 0.000 -16.429 0.000 -32.372 -3.633
F8 NW APARTMENT 31.280 -3.678 0.000 0.000 3.918 1.087 12.213 7.402 0.000 0.147 0.000 0.000 -17.725 0.000 -31.690 -2.954
F8 SE APARTMENT 24.654 -5.483 0.000 0.000 3.894 1.087 12.213 15.626 0.000 0.148 0.000 0.000 -16.198 0.000 -32.392 -3.549
F8 NE APARTMENT 31.122 -3.382 0.000 0.000 3.925 1.087 12.213 6.885 0.000 0.148 0.000 0.000 -17.395 0.000 -31.712 -2.890
F8 N1 APARTMENT 16.074 -3.430 0.000 0.000 3.923 1.087 12.213 2.282 0.000 0.114 0.000 0.000 -11.299 0.000 -20.443 -0.519
F8 N2 APARTMENT 16.073 -3.421 0.000 0.000 3.924 1.087 12.213 2.282 0.000 0.114 0.000 0.000 -11.297 0.000 -20.442 -0.530
F8 S1 APARTMENT 10.634 -6.084 0.000 0.000 3.874 1.087 12.213 11.153 0.000 0.116 0.000 0.000 -10.033 0.000 -21.223 -1.737
F8 S2 APARTMENT 10.634 -6.066 0.000 0.000 3.874 1.087 12.213 11.152 0.000 0.116 0.000 0.000 -10.031 0.000 -21.225 -1.754
F9 SW APARTMENT 27.170 -5.507 0.000 0.000 3.892 1.087 12.213 16.025 0.000 0.154 0.000 0.000 -16.431 0.000 -33.605 -4.996
F9 NW APARTMENT 33.765 -3.536 0.000 0.000 3.921 1.087 12.213 7.392 0.000 0.152 0.000 0.000 -17.746 0.000 -32.925 -4.322
F9 SE APARTMENT 27.002 -5.158 0.000 0.000 3.898 1.087 12.213 15.598 0.000 0.154 0.000 0.000 -16.201 0.000 -33.644 -4.948
F9 NE APARTMENT 33.592 -3.237 0.000 0.000 3.927 1.087 12.213 6.875 0.000 0.153 0.000 0.000 -17.413 0.000 -32.955 -4.242
F9 N1 APARTMENT 17.925 -3.255 0.000 0.000 3.926 1.087 12.213 2.282 0.000 0.119 0.000 0.000 -11.310 0.000 -21.211 -1.775
F9 N2 APARTMENT 17.924 -3.245 0.000 0.000 3.927 1.087 12.213 2.281 0.000 0.119 0.000 0.000 -11.308 0.000 -21.211 -1.784
F9 S1 APARTMENT 12.205 -5.679 0.000 0.000 3.880 1.087 12.213 11.134 0.000 0.120 0.000 0.000 -10.029 0.000 -21.987 -2.945
F9 S2 APARTMENT 12.206 -5.662 0.000 0.000 3.881 1.087 12.213 11.133 0.000 0.121 0.000 0.000 -10.026 0.000 -21.989 -2.961
T SW APARTMENT 35.413 -5.740 0.000 0.000 3.916 1.087 12.213 15.844 0.000 0.157 0.000 0.000 -15.949 0.000 -34.675 -12.265
T NW APARTMENT 41.045 -3.762 0.000 0.000 3.938 1.087 12.213 7.273 0.000 0.155 0.000 0.000 -17.316 0.000 -34.025 -10.607
T SE APARTMENT 35.058 -5.234 0.000 0.000 3.924 1.087 12.213 15.444 0.000 0.157 0.000 0.000 -15.741 0.000 -34.723 -12.184
T NE APARTMENT 40.817 -3.324 0.000 0.000 3.944 1.087 12.213 6.777 0.000 0.156 0.000 0.000 -17.007 0.000 -34.088 -10.573
T N1 APARTMENT 24.441 -3.003 0.000 0.000 3.940 1.087 12.213 2.250 0.000 0.123 0.000 0.000 -11.031 0.000 -21.918 -8.102
T N2 APARTMENT 24.437 -2.989 0.000 0.000 3.941 1.087 12.213 2.248 0.000 0.123 0.000 0.000 -11.027 0.000 -21.923 -8.108
T S1 APARTMENT 19.138 -5.112 0.000 0.000 3.904 1.087 12.213 11.040 0.000 0.124 0.000 0.000 -9.772 0.000 -22.663 -9.959
T S2 APARTMENT 19.141 -5.102 0.000 0.000 3.904 1.087 12.213 11.036 0.000 0.124 0.000 0.000 -9.768 0.000 -22.668 -9.968
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 3.684 0.000 0.180 73.886 0.000 -3.250 0.000 -90.940 -0.000
F2 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.631 0.000 0.003 0.000 0.000 -2.015 0.000 -2.843 -13.215
F3 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.588 0.000 0.003 0.000 0.000 -2.101 0.000 -3.445 -12.484
F4 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.566 0.000 0.003 0.000 0.000 -2.136 0.000 -3.874 -11.998
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 32.880 0.000 1.542 0.000 0.003 0.000 0.000 -2.180 0.000 -4.321 -27.924
F6 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.550 0.000 0.004 0.000 0.000 -2.156 0.000 -4.484 -11.354
F7 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.549 0.000 0.004 0.000 0.000 -2.151 0.000 -4.707 -11.136
F8 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.546 0.000 0.004 0.000 0.000 -2.151 0.000 -4.918 -10.921
F9 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.545 0.000 0.004 0.000 0.000 -2.146 0.000 -5.098 -10.745
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 8.151 1.511 0.000 0.002 0.000 0.000 -2.098 0.000 -5.338 -18.668
Total Facility 1490.671 -411.616 0.000 0.000 308.459 296.560 982.450 759.650 0.000 9.184 75.738 0.000 -1102.703 0.000 -1915.737 -492.654


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 25-AUG-16:15 0.00 -2269.25 0.00 0.00 84.77 64.86 588.62 2807.36 0.00 165.39 0.00 0.00 0.00 0.00 0.00 -1441.75
G NW APARTMENT 06-JUL-17:45 0.00 -2035.98 0.00 0.00 141.82 87.56 588.62 2808.28 0.00 137.97 0.00 0.00 0.00 0.00 0.00 -1728.26
OFFICE 17-JUL-13:45 0.00 -3427.17 0.00 0.00 65.20 2345.88 588.62 2329.71 0.00 90.73 0.00 0.00 0.00 0.00 0.00 -1992.96
G NE APARTMENT 26-JUN-09:30 0.00 -1667.10 0.00 0.00 40.76 12.97 406.15 2388.08 0.00 288.51 0.00 0.00 0.00 0.00 0.00 -1469.37
G N1 APARTMENT 29-JUN-18:30 0.00 -1214.43 0.00 0.00 141.82 103.77 547.42 752.35 0.00 295.94 0.00 0.00 0.00 0.00 0.00 -626.88
G N2 APARTMENT 29-JUN-18:30 0.00 -1202.76 0.00 0.00 141.82 103.77 547.42 752.64 0.00 295.94 0.00 0.00 0.00 0.00 0.00 -638.83
G S1 APARTMENT 11-AUG-12:45 0.00 -1582.29 0.00 0.00 40.75 12.97 388.49 2553.86 0.00 225.25 0.00 0.00 0.00 0.00 0.00 -1639.03
G S2 APARTMENT 11-AUG-12:45 0.00 -1583.81 0.00 0.00 40.59 12.97 388.49 2552.02 0.00 215.00 0.00 0.00 0.00 0.00 0.00 -1625.27
F2 SW APARTMENT 25-AUG-16:15 0.00 -2964.18 0.00 0.00 84.77 64.86 588.62 2772.53 0.00 192.09 0.00 0.00 0.00 0.00 0.00 -738.68
F2 NW APARTMENT 19-JUL-17:30 0.00 -2647.95 0.00 0.00 141.82 87.56 588.62 2607.88 0.00 198.80 0.00 0.00 0.00 0.00 0.00 -976.72
F2 SE APARTMENT 17-JUL-12:00 0.00 -2905.83 0.00 0.00 40.75 12.97 406.15 2620.77 0.00 195.57 0.00 0.00 0.00 0.00 0.00 -370.39
F2 NE APARTMENT 17-JUL-10:15 0.00 -2215.58 0.00 0.00 40.56 12.97 412.03 2164.22 0.00 13.19 0.00 0.00 0.00 0.00 0.00 -427.40
F2 N1 APARTMENT 19-JUL-17:30 0.00 -1406.07 0.00 0.00 141.82 87.56 588.62 402.72 0.00 186.74 0.00 0.00 0.00 0.00 0.00 -1.38
F2 N2 APARTMENT 19-JUL-17:15 0.00 -1395.51 0.00 0.00 141.82 87.56 588.62 355.27 0.00 219.51 2.74 0.00 0.00 0.00 0.00 0.00
F2 S1 APARTMENT 11-AUG-12:45 0.00 -2044.91 0.00 0.00 40.65 12.97 388.49 2526.17 0.00 255.69 0.00 0.00 0.00 0.00 0.00 -1179.07
F2 S2 APARTMENT 11-AUG-12:45 0.00 -2071.39 0.00 0.00 40.67 12.97 388.49 2525.87 0.00 256.45 0.00 0.00 0.00 0.00 0.00 -1153.06
F3 SW APARTMENT 18-MAY-18:00 0.00 -3108.34 0.00 0.00 141.81 87.56 588.62 2219.77 0.00 396.17 0.00 0.00 0.00 0.00 0.00 -325.59
F3 NW APARTMENT 18-MAY-18:00 0.00 -2813.94 0.00 0.00 141.81 87.56 588.62 2539.54 0.00 396.18 0.00 0.00 0.00 0.00 0.00 -939.78
F3 SE APARTMENT 17-JUL-12:00 0.00 -2853.69 0.00 0.00 40.75 12.97 406.15 2604.32 0.00 230.40 0.00 0.00 0.00 0.00 0.00 -440.91
F3 NE APARTMENT 17-JUL-09:45 0.00 -2296.60 0.00 0.00 40.60 12.97 406.15 2444.59 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -607.72
F3 N1 APARTMENT 19-JUL-17:15 0.00 -1475.36 0.00 0.00 141.82 87.56 588.62 352.71 0.00 235.48 69.18 0.00 0.00 0.00 0.00 0.00
F3 N2 APARTMENT 19-JUL-17:15 0.00 -1464.70 0.00 0.00 141.82 87.56 588.62 352.89 0.00 235.48 58.33 0.00 0.00 0.00 0.00 0.00
F3 S1 APARTMENT 19-JUL-14:00 0.00 -2114.42 0.00 0.00 40.75 12.97 382.60 1610.50 0.00 426.86 0.00 0.00 0.00 0.00 0.00 -359.26
F3 S2 APARTMENT 19-JUL-14:00 0.00 -2122.89 0.00 0.00 40.75 12.97 382.60 1610.33 0.00 426.86 0.00 0.00 0.00 0.00 0.00 -350.63
F4 SW APARTMENT 18-MAY-18:00 0.00 -3161.64 0.00 0.00 141.81 87.56 588.62 2210.25 0.00 426.59 0.00 0.00 0.00 0.00 0.00 -293.20
F4 NW APARTMENT 18-MAY-18:00 0.00 -2876.37 0.00 0.00 141.81 87.56 588.62 2527.00 0.00 426.61 0.00 0.00 0.00 0.00 0.00 -895.22
F4 SE APARTMENT 17-JUL-11:45 0.00 -2874.32 0.00 0.00 40.75 12.97 406.15 2662.30 0.00 211.49 0.00 0.00 0.00 0.00 0.00 -459.35
F4 NE APARTMENT 17-JUL-09:15 0.00 -2297.19 0.00 0.00 40.76 12.97 406.15 2659.68 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -822.37
F4 N1 APARTMENT 18-MAY-18:00 0.00 -1513.13 0.00 0.00 141.81 87.56 588.62 473.82 0.00 398.20 0.00 0.00 0.00 0.00 0.00 -176.87
F4 N2 APARTMENT 18-MAY-18:00 0.00 -1492.95 0.00 0.00 141.81 87.56 588.62 474.25 0.00 398.20 0.00 0.00 0.00 0.00 0.00 -197.49
F4 S1 APARTMENT 19-JUL-14:00 0.00 -2155.44 0.00 0.00 40.75 12.97 382.60 1598.83 0.00 462.15 0.00 0.00 0.00 0.00 0.00 -341.87
F4 S2 APARTMENT 19-JUL-14:00 0.00 -2163.00 0.00 0.00 40.75 12.97 382.60 1598.67 0.00 462.15 0.00 0.00 0.00 0.00 0.00 -334.14
M SW APARTMENT 18-MAY-18:00 0.00 -3205.20 0.00 0.00 141.81 87.56 588.62 2202.51 0.00 451.04 0.00 0.00 0.00 0.00 0.00 -266.34
M NW APARTMENT 18-MAY-18:00 0.00 -2921.08 0.00 0.00 141.81 87.56 588.62 2517.20 0.00 451.05 0.00 0.00 0.00 0.00 0.00 -865.16
M SE APARTMENT 17-JUL-11:45 0.00 -2916.31 0.00 0.00 40.75 12.97 406.15 2651.74 0.00 229.17 0.00 0.00 0.00 0.00 0.00 -424.46
M NE APARTMENT 17-JUL-09:15 0.00 -2314.49 0.00 0.00 40.76 12.97 406.15 2658.71 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -804.10
M N1 APARTMENT 18-MAY-18:00 0.00 -1563.96 0.00 0.00 141.81 87.56 588.62 471.70 0.00 420.46 0.00 0.00 0.00 0.00 0.00 -146.19
M N2 APARTMENT 18-MAY-18:00 0.00 -1544.15 0.00 0.00 141.81 87.56 588.62 472.12 0.00 420.46 0.00 0.00 0.00 0.00 0.00 -166.42
M S1 APARTMENT 19-JUL-14:00 0.00 -2204.96 0.00 0.00 40.75 12.97 382.60 1589.62 0.00 490.45 0.00 0.00 0.00 0.00 0.00 -311.44
M S2 APARTMENT 19-JUL-14:00 0.00 -2212.40 0.00 0.00 40.75 12.97 382.60 1589.47 0.00 490.44 0.00 0.00 0.00 0.00 0.00 -303.84
F6 SW APARTMENT 18-MAY-18:00 0.00 -3179.34 0.00 0.00 141.81 87.56 588.62 2197.76 0.00 471.41 0.00 0.00 0.00 0.00 0.00 -307.82
F6 NW APARTMENT 18-MAY-18:00 0.00 -2888.13 0.00 0.00 141.81 87.56 588.62 2510.95 0.00 471.42 0.00 0.00 0.00 0.00 0.00 -912.23
F6 SE APARTMENT 17-JUL-11:45 0.00 -2896.02 0.00 0.00 40.75 12.97 406.15 2644.40 0.00 244.20 0.00 0.00 0.00 0.00 0.00 -452.46
F6 NE APARTMENT 17-JUL-07:45 0.00 -2338.74 0.00 0.00 63.58 19.46 388.49 2687.29 0.00 282.43 0.00 0.00 0.00 0.00 0.00 -1102.51
F6 N1 APARTMENT 18-MAY-18:00 0.00 -1537.61 0.00 0.00 141.81 87.56 588.62 471.42 0.00 439.00 0.00 0.00 0.00 0.00 0.00 -190.80
F6 N2 APARTMENT 18-MAY-18:00 0.00 -1518.55 0.00 0.00 141.81 87.56 588.62 471.83 0.00 439.00 0.00 0.00 0.00 0.00 0.00 -210.26
F6 S1 APARTMENT 19-JUL-14:00 0.00 -2190.84 0.00 0.00 40.75 12.97 382.60 1583.13 0.00 514.00 0.00 0.00 0.00 0.00 0.00 -342.62
F6 S2 APARTMENT 19-JUL-14:00 0.00 -2198.32 0.00 0.00 40.75 12.97 382.60 1582.97 0.00 514.00 0.00 0.00 0.00 0.00 0.00 -334.98
F7 SW APARTMENT 18-MAY-18:00 0.00 -3170.14 0.00 0.00 141.81 87.56 588.62 2193.18 0.00 488.76 0.00 0.00 0.00 0.00 0.00 -329.79
F7 NW APARTMENT 18-MAY-18:00 0.00 -2873.74 0.00 0.00 141.81 87.56 588.62 2505.14 0.00 488.78 0.00 0.00 0.00 0.00 0.00 -938.16
F7 SE APARTMENT 17-JUL-11:45 0.00 -2894.78 0.00 0.00 40.75 12.97 406.15 2637.58 0.00 257.35 0.00 0.00 0.00 0.00 0.00 -460.03
F7 NE APARTMENT 17-JUL-19:00 0.00 -2343.61 0.00 0.00 141.83 103.77 547.42 382.62 0.00 619.83 548.14 0.00 0.00 0.00 0.00 0.00
F7 N1 APARTMENT 26-MAY-15:45 0.00 -1557.40 0.00 0.00 48.90 45.40 470.89 599.94 0.00 600.82 0.00 0.00 0.00 0.00 0.00 -208.56
F7 N2 APARTMENT 26-MAY-15:45 0.00 -1556.55 0.00 0.00 48.90 45.40 470.89 600.27 0.00 603.25 0.00 0.00 0.00 0.00 0.00 -212.17
F7 S1 APARTMENT 19-JUL-14:00 0.00 -2194.45 0.00 0.00 40.75 12.97 382.60 1577.30 0.00 534.06 0.00 0.00 0.00 0.00 0.00 -353.23
F7 S2 APARTMENT 19-JUL-14:00 0.00 -2201.99 0.00 0.00 40.75 12.97 382.60 1577.14 0.00 534.06 0.00 0.00 0.00 0.00 0.00 -345.54
F8 SW APARTMENT 18-MAY-18:00 0.00 -3168.31 0.00 0.00 141.81 87.56 588.62 2188.91 0.00 503.77 0.00 0.00 0.00 0.00 0.00 -342.36
F8 NW APARTMENT 18-MAY-18:00 0.00 -2872.28 0.00 0.00 141.81 87.56 588.62 2499.64 0.00 503.78 0.00 0.00 0.00 0.00 0.00 -949.12
F8 SE APARTMENT 17-JUL-12:00 0.00 -2924.90 0.00 0.00 40.75 12.97 406.15 2560.71 0.00 326.75 0.00 0.00 0.00 0.00 0.00 -422.43
F8 NE APARTMENT 17-JUL-19:00 0.00 -2365.60 0.00 0.00 141.83 103.77 547.42 381.61 0.00 640.77 550.21 0.00 0.00 0.00 0.00 0.00
F8 N1 APARTMENT 28-JUN-18:15 0.00 -1622.40 0.00 0.00 141.83 103.77 547.42 651.31 0.00 557.13 0.00 0.00 0.00 0.00 0.00 -379.06
F8 N2 APARTMENT 28-JUN-18:15 0.00 -1622.61 0.00 0.00 141.83 103.77 547.42 651.54 0.00 559.15 0.00 0.00 0.00 0.00 0.00 -381.09
F8 S1 APARTMENT 19-JUL-14:00 0.00 -2205.25 0.00 0.00 40.75 12.97 382.60 1572.06 0.00 551.41 0.00 0.00 0.00 0.00 0.00 -354.55
F8 S2 APARTMENT 19-JUL-14:00 0.00 -2212.86 0.00 0.00 40.75 12.97 382.60 1571.90 0.00 551.41 0.00 0.00 0.00 0.00 0.00 -346.78
F9 SW APARTMENT 18-MAY-17:45 0.00 -3310.36 0.00 0.00 141.81 87.56 588.62 2369.24 0.00 536.31 0.00 0.00 0.00 0.00 0.00 -413.17
F9 NW APARTMENT 18-MAY-17:45 0.00 -2972.35 0.00 0.00 141.81 87.56 588.62 2584.69 0.00 536.31 0.00 0.00 0.00 0.00 0.00 -966.63
F9 SE APARTMENT 17-JUL-12:00 0.00 -3006.89 0.00 0.00 40.75 12.97 406.15 2553.56 0.00 340.24 0.00 0.00 0.00 0.00 0.00 -346.78
F9 NE APARTMENT 17-JUL-18:45 0.00 -2474.46 0.00 0.00 141.83 103.77 547.42 405.84 0.00 648.86 626.74 0.00 0.00 0.00 0.00 0.00
F9 N1 APARTMENT 28-JUN-18:15 0.00 -1745.72 0.00 0.00 141.83 103.77 547.42 648.88 0.00 585.00 0.00 0.00 0.00 0.00 0.00 -281.18
F9 N2 APARTMENT 28-JUN-18:15 0.00 -1745.91 0.00 0.00 141.83 103.77 547.42 649.10 0.00 587.07 0.00 0.00 0.00 0.00 0.00 -283.28
F9 S1 APARTMENT 19-JUL-14:00 0.00 -2252.40 0.00 0.00 40.75 12.97 382.60 1566.64 0.00 566.57 0.00 0.00 0.00 0.00 0.00 -317.14
F9 S2 APARTMENT 19-JUL-14:00 0.00 -2261.19 0.00 0.00 40.75 12.97 382.60 1566.46 0.00 566.57 0.00 0.00 0.00 0.00 0.00 -308.17
T SW APARTMENT 17-JUL-14:15 0.00 -3784.10 0.00 0.00 40.75 22.70 400.26 2958.84 0.00 312.93 48.62 0.00 0.00 0.00 0.00 0.00
T NW APARTMENT 18-MAY-17:45 0.00 -3507.96 0.00 0.00 141.81 87.56 588.62 2546.10 0.00 548.29 0.00 0.00 0.00 0.00 0.00 -404.41
T SE APARTMENT 17-JUL-11:30 0.00 -3679.46 0.00 0.00 40.75 12.97 406.15 2677.92 0.00 226.67 315.00 0.00 0.00 0.00 0.00 0.00
T NE APARTMENT 17-JUL-10:15 0.00 -2930.20 0.00 0.00 40.75 12.97 412.03 2124.97 0.00 23.80 315.67 0.00 0.00 0.00 0.00 0.00
T N1 APARTMENT 28-JUN-18:15 0.00 -2258.06 0.00 0.00 141.83 103.77 547.42 638.84 0.00 641.27 184.93 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 28-JUN-18:15 0.00 -2253.34 0.00 0.00 141.83 103.77 547.42 639.51 0.00 645.77 175.04 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 17-JUL-14:00 0.00 -2949.51 0.00 0.00 40.54 12.97 382.60 1652.46 0.00 191.79 669.15 0.00 0.00 0.00 0.00 0.00
T S2 APARTMENT 17-JUL-14:00 0.00 -2954.02 0.00 0.00 40.54 12.97 382.60 1652.32 0.00 191.80 673.79 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 17-JUL-14:15 0.00 -168898.75 0.00 0.00 3284.64 9873.49 32370.09 129684.23 0.00 16821.65 0.00 0.00 0.00 0.00 0.00 -23135.34


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 11-JAN-12:00 3770.99 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1037.87 0.00 -2345.39 -860.15
G NW APARTMENT 11-JAN-12:00 3888.48 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1190.66 0.00 -2345.39 -824.85
OFFICE 19-DEC-03:00 3528.72 0.00 0.00 0.00 0.00 469.18 194.24 0.00 0.00 0.00 0.00 0.00 -1711.26 0.00 -2083.70 -397.18
G NE APARTMENT 11-JAN-12:00 3851.26 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1168.37 0.00 -2345.39 -809.92
G N1 APARTMENT 08-JAN-08:30 2549.67 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -1013.75 0.00 -939.23 -1078.61
G N2 APARTMENT 08-JAN-08:30 2547.21 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -1013.78 0.00 -939.23 -1076.12
G S1 APARTMENT 11-JAN-12:00 2319.32 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -573.78 0.00 -1414.68 -803.28
G S2 APARTMENT 11-JAN-12:00 2278.28 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -574.73 0.00 -1414.68 -761.29
F2 SW APARTMENT 19-DEC-03:00 4550.13 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 0.00 0.00 -1778.69 0.00 -2995.77 -201.39
F2 NW APARTMENT 19-DEC-03:00 4729.68 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 0.00 0.00 -1799.12 0.00 -2995.77 -360.51
F2 SE APARTMENT 19-DEC-03:00 4474.72 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 0.00 0.00 -1762.58 0.00 -2995.77 -142.09
F2 NE APARTMENT 19-DEC-03:00 4727.69 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 0.00 0.00 -1780.67 0.00 -2995.78 -376.95
F2 N1 APARTMENT 19-DEC-03:00 2785.67 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 0.00 0.00 -1098.29 0.00 -1806.98 -306.11
F2 N2 APARTMENT 19-DEC-03:00 2786.01 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 0.00 0.00 -1098.28 0.00 -1806.99 -306.46
F2 S1 APARTMENT 19-DEC-03:00 2591.60 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 0.00 0.00 -1073.91 0.00 -1806.97 -136.43
F2 S2 APARTMENT 19-DEC-03:00 2586.62 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 0.00 0.00 -1074.02 0.00 -1806.97 -131.34
F3 SW APARTMENT 11-JAN-12:00 5066.56 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1162.15 0.00 -3993.42 -383.41
F3 NW APARTMENT 11-JAN-12:00 5194.03 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1308.38 0.00 -3993.43 -364.64
F3 SE APARTMENT 11-JAN-12:00 5014.90 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1129.25 0.00 -3993.43 -364.65
F3 NE APARTMENT 19-DEC-03:00 5181.38 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 0.00 0.00 -1807.85 0.00 -3547.68 -251.56
F3 N1 APARTMENT 19-DEC-03:00 3017.12 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 0.00 0.00 -1117.25 0.00 -2139.88 -185.71
F3 N2 APARTMENT 19-DEC-03:00 3017.37 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 0.00 0.00 -1117.24 0.00 -2139.88 -185.96
F3 S1 APARTMENT 11-JAN-12:00 2862.98 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -651.65 0.00 -2408.73 -275.03
F3 S2 APARTMENT 11-JAN-12:00 2860.97 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -651.70 0.00 -2408.73 -272.96
F4 SW APARTMENT 11-JAN-12:00 5534.61 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1182.81 0.00 -4464.80 -359.43
F4 NW APARTMENT 11-JAN-12:00 5661.41 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1327.94 0.00 -4464.81 -341.09
F4 SE APARTMENT 11-JAN-12:00 5488.45 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1147.84 0.00 -4464.81 -348.22
F4 NE APARTMENT 11-JAN-12:00 5613.80 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1293.13 0.00 -4464.82 -328.26
F4 N1 APARTMENT 11-JAN-12:00 3265.12 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -813.89 0.00 -2693.09 -230.56
F4 N2 APARTMENT 11-JAN-12:00 3263.84 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -813.92 0.00 -2693.10 -229.25
F4 S1 APARTMENT 11-JAN-12:00 3135.47 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -664.85 0.00 -2693.06 -249.98
F4 S2 APARTMENT 11-JAN-12:00 3134.08 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -664.88 0.00 -2693.06 -248.56
M SW APARTMENT 11-JAN-12:00 5912.61 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1198.36 0.00 -4853.51 -333.17
M NW APARTMENT 11-JAN-12:00 6037.06 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1342.68 0.00 -4853.52 -313.27
M SE APARTMENT 11-JAN-12:00 5866.54 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1162.12 0.00 -4853.51 -323.32
M NE APARTMENT 11-JAN-12:00 5988.81 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1306.65 0.00 -4853.53 -301.06
M N1 APARTMENT 11-JAN-12:00 3482.46 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -823.02 0.00 -2927.55 -204.30
M N2 APARTMENT 11-JAN-12:00 3481.18 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -823.06 0.00 -2927.55 -202.99
M S1 APARTMENT 11-JAN-12:00 3355.19 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -674.75 0.00 -2927.51 -225.35
M S2 APARTMENT 11-JAN-12:00 3353.90 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -674.78 0.00 -2927.51 -224.03
F6 SW APARTMENT 11-JAN-12:00 6289.61 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1208.74 0.00 -5188.61 -364.69
F6 NW APARTMENT 11-JAN-12:00 6413.85 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1352.54 0.00 -5188.62 -345.11
F6 SE APARTMENT 11-JAN-12:00 6243.01 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1171.64 0.00 -5188.61 -355.17
F6 NE APARTMENT 11-JAN-12:00 6364.93 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1315.64 0.00 -5188.62 -333.10
F6 N1 APARTMENT 11-JAN-12:00 3720.93 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -829.01 0.00 -3129.67 -234.66
F6 N2 APARTMENT 11-JAN-12:00 3719.63 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -829.04 0.00 -3129.67 -233.34
F6 S1 APARTMENT 11-JAN-12:00 3593.75 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -681.26 0.00 -3129.64 -255.27
F6 S2 APARTMENT 11-JAN-12:00 3592.47 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -681.29 0.00 -3129.64 -253.96
F7 SW APARTMENT 11-JAN-12:00 6609.71 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1217.75 0.00 -5485.64 -378.75
F7 NW APARTMENT 11-JAN-12:00 6732.44 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1361.13 0.00 -5485.65 -358.09
F7 SE APARTMENT 11-JAN-12:00 6562.72 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1180.00 0.00 -5485.64 -369.50
F7 NE APARTMENT 11-JAN-12:00 6683.03 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1323.57 0.00 -5485.64 -346.23
F7 N1 APARTMENT 11-JAN-12:00 3918.45 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -834.23 0.00 -3308.83 -247.80
F7 N2 APARTMENT 11-JAN-12:00 3917.15 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -834.27 0.00 -3308.83 -246.48
F7 S1 APARTMENT 11-JAN-12:00 3793.22 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -686.90 0.00 -3308.80 -269.93
F7 S2 APARTMENT 11-JAN-12:00 3791.94 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -686.93 0.00 -3308.80 -268.63
F8 SW APARTMENT 11-JAN-12:00 6904.01 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1225.25 0.00 -5754.00 -397.17
F8 NW APARTMENT 11-JAN-12:00 7024.49 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1368.28 0.00 -5754.01 -374.62
F8 SE APARTMENT 11-JAN-12:00 6856.71 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1186.97 0.00 -5754.01 -388.15
F8 NE APARTMENT 11-JAN-12:00 6974.76 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1330.21 0.00 -5754.01 -362.96
F8 N1 APARTMENT 11-JAN-12:00 4101.53 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -838.56 0.00 -3470.70 -264.68
F8 N2 APARTMENT 11-JAN-12:00 4100.24 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -838.60 0.00 -3470.70 -263.36
F8 S1 APARTMENT 11-JAN-12:00 3979.48 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -691.55 0.00 -3470.68 -289.68
F8 S2 APARTMENT 11-JAN-12:00 3978.22 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -691.58 0.00 -3470.68 -288.38
F9 SW APARTMENT 11-JAN-12:00 7259.21 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1228.98 0.00 -5999.89 -502.77
F9 NW APARTMENT 11-JAN-12:00 7376.75 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1371.72 0.00 -5999.89 -477.56
F9 SE APARTMENT 11-JAN-12:00 7209.88 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1190.35 0.00 -5999.89 -492.07
F9 NE APARTMENT 11-JAN-12:00 7324.91 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1333.31 0.00 -5999.89 -464.13
F9 N1 APARTMENT 11-JAN-12:00 4346.46 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -840.52 0.00 -3619.01 -359.36
F9 N2 APARTMENT 11-JAN-12:00 4345.10 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -840.55 0.00 -3619.01 -357.96
F9 S1 APARTMENT 11-JAN-12:00 4228.55 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -693.77 0.00 -3618.99 -388.21
F9 S2 APARTMENT 11-JAN-12:00 4227.23 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -693.80 0.00 -3618.99 -386.86
T SW APARTMENT 11-JAN-12:00 8002.60 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1204.86 0.00 -6227.07 -1043.09
T NW APARTMENT 11-JAN-12:00 8126.49 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1346.29 0.00 -6227.08 -1025.54
T SE APARTMENT 19-DEC-03:00 7966.09 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 0.00 0.00 -1793.75 0.00 -5530.94 -1067.11
T NE APARTMENT 11-JAN-12:00 8073.00 0.00 0.00 0.00 47.42 12.97 412.03 0.00 0.00 0.00 0.00 0.00 -1308.22 0.00 -6227.08 -1010.13
T N1 APARTMENT 19-DEC-03:00 5118.17 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 0.00 0.00 -1132.25 0.00 -3336.25 -1075.38
T N2 APARTMENT 19-DEC-03:00 5118.01 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 0.00 0.00 -1132.26 0.00 -3336.25 -1075.21
T S1 APARTMENT 19-DEC-03:00 5003.77 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 0.00 0.00 -1096.11 0.00 -3336.25 -997.13
T S2 APARTMENT 19-DEC-03:00 5003.53 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 0.00 0.00 -1096.11 0.00 -3336.25 -996.89
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 11-JAN-12:00 381124.82 0.00 0.00 0.00 3821.78 9104.94 33300.10 0.00 0.00 0.00 0.00 0.00 -80496.53 0.00 -321750.20 -25104.91



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Sec1.1A-General Information

Data
Weather File Duluth International Arpt MN USA TMY3 WMO#=727450
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 7836.48
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.50
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
F2 SW APARTMENT 88.25 88.25 0.00 168.00
F2 NW APARTMENT 88.25 88.25 0.00 168.00
F2 SE APARTMENT 88.25 88.25 0.00 168.00
F2 NE APARTMENT 88.25 88.25 0.00 168.00
F2 N1 APARTMENT 88.25 88.25 0.00 168.00
F2 N2 APARTMENT 88.25 88.25 0.00 168.00
F2 S1 APARTMENT 88.25 88.25 0.00 168.00
F2 S2 APARTMENT 88.25 88.25 0.00 168.00
F3 SW APARTMENT 88.25 88.25 0.00 168.00
F3 NW APARTMENT 88.25 88.25 0.00 168.00
F3 SE APARTMENT 88.25 88.25 0.00 168.00
F3 NE APARTMENT 88.25 88.25 0.00 168.00
F3 N1 APARTMENT 88.25 88.25 0.00 168.00
F3 N2 APARTMENT 88.25 88.25 0.00 168.00
F3 S1 APARTMENT 88.25 88.25 0.00 168.00
F3 S2 APARTMENT 88.25 88.25 0.00 168.00
F4 SW APARTMENT 88.25 88.25 0.00 168.00
F4 NW APARTMENT 88.25 88.25 0.00 168.00
F4 SE APARTMENT 88.25 88.25 0.00 168.00
F4 NE APARTMENT 88.25 88.25 0.00 168.00
F4 N1 APARTMENT 88.25 88.25 0.00 168.00
F4 N2 APARTMENT 88.25 88.25 0.00 168.00
F4 S1 APARTMENT 88.25 88.25 0.00 168.00
F4 S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
F6 SW APARTMENT 88.25 88.25 0.00 168.00
F6 NW APARTMENT 88.25 88.25 0.00 168.00
F6 SE APARTMENT 88.25 88.25 0.00 168.00
F6 NE APARTMENT 88.25 88.25 0.00 168.00
F6 N1 APARTMENT 88.25 88.25 0.00 168.00
F6 N2 APARTMENT 88.25 88.25 0.00 168.00
F6 S1 APARTMENT 88.25 88.25 0.00 168.00
F6 S2 APARTMENT 88.25 88.25 0.00 168.00
F7 SW APARTMENT 88.25 88.25 0.00 168.00
F7 NW APARTMENT 88.25 88.25 0.00 168.00
F7 SE APARTMENT 88.25 88.25 0.00 168.00
F7 NE APARTMENT 88.25 88.25 0.00 168.00
F7 N1 APARTMENT 88.25 88.25 0.00 168.00
F7 N2 APARTMENT 88.25 88.25 0.00 168.00
F7 S1 APARTMENT 88.25 88.25 0.00 168.00
F7 S2 APARTMENT 88.25 88.25 0.00 168.00
F8 SW APARTMENT 88.25 88.25 0.00 168.00
F8 NW APARTMENT 88.25 88.25 0.00 168.00
F8 SE APARTMENT 88.25 88.25 0.00 168.00
F8 NE APARTMENT 88.25 88.25 0.00 168.00
F8 N1 APARTMENT 88.25 88.25 0.00 168.00
F8 N2 APARTMENT 88.25 88.25 0.00 168.00
F8 S1 APARTMENT 88.25 88.25 0.00 168.00
F8 S2 APARTMENT 88.25 88.25 0.00 168.00
F9 SW APARTMENT 88.25 88.25 0.00 168.00
F9 NW APARTMENT 88.25 88.25 0.00 168.00
F9 SE APARTMENT 88.25 88.25 0.00 168.00
F9 NE APARTMENT 88.25 88.25 0.00 168.00
F9 N1 APARTMENT 88.25 88.25 0.00 168.00
F9 N2 APARTMENT 88.25 88.25 0.00 168.00
F9 S1 APARTMENT 88.25 88.25 0.00 168.00
F9 S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
G CORRIDOR 77.66 0.00 77.66 0.00
F2 CORRIDOR 77.66 0.00 77.66 0.00
F3 CORRIDOR 77.66 0.00 77.66 0.00
F4 CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
F6 CORRIDOR 77.66 0.00 77.66 0.00
F7 CORRIDOR 77.66 0.00 77.66 0.00
F8 CORRIDOR 77.66 0.00 77.66 0.00
F9 CORRIDOR 77.66 0.00 77.66 0.00
T CORRIDOR 77.66 0.00 77.66 0.00
Totals 7836.48 7059.89 776.58  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 109.00
Number of hours cooling loads not met 51.75
Number of hours not met 160.75


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 296.56 9104.94 0.00 0.00 0.00 0.00
Exterior Lighting 162.58 0.00 0.00 0.00 0.00 0.00
Space Heating 567.85 222001.39 2181.16 329031.97 0.00 0.00
Space Cooling 144.53 0.00 0.00 0.00 0.00 0.00
Pumps 65.89 2145.84 0.00 0.00 0.00 0.00
Heat Rejection 6.37 0.00 0.00 0.00 0.00 0.00
Fans-Interior 631.26 20017.05 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 0.00 0.00 1343.09 86889.94 0.00 0.00
Receptacle Equipment 1137.32 36356.63 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 3048.54   3524.24   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 1137.32 3048.54
Natural Gas 0.00 3524.24
Additional 0.00 0.00
Total 1137.32 6572.78


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 37.84
Space Heating 72.46
Space Cooling 18.44
Fans-Interior 80.55
Service Water Heating 0.00
Receptacle Equipment 145.13
Miscellaneous 34.58
Subtotal 389.02


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 278.33
Service Water Heating 171.39
Miscellaneous -0.00
Subtotal 449.72


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 4.51
Space Heating 41.82
Space Cooling 2.20
Fans-Interior 9.60
Service Water Heating 20.43
Receptacle Equipment 17.30
Miscellaneous 4.12



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.205722
G NW APARTMENT DIRECT AIR 0.204303
OFFICE DIRECT AIR 0.330758
G NE APARTMENT DIRECT AIR 0.204414
G N1 APARTMENT DIRECT AIR 0.140109
G N2 APARTMENT DIRECT AIR 0.140111
G S1 APARTMENT DIRECT AIR 0.139644
G S2 APARTMENT DIRECT AIR 0.139944
F2 SW APARTMENT DIRECT AIR 0.276460
F2 NW APARTMENT DIRECT AIR 0.246600
F2 SE APARTMENT DIRECT AIR 0.274256
F2 NE APARTMENT DIRECT AIR 0.202350
F2 N1 APARTMENT DIRECT AIR 0.127011
F2 N2 APARTMENT DIRECT AIR 0.125501
F2 S1 APARTMENT DIRECT AIR 0.183383
F2 S2 APARTMENT DIRECT AIR 0.185963
F3 SW APARTMENT DIRECT AIR 0.278474
F3 NW APARTMENT DIRECT AIR 0.250036
F3 SE APARTMENT DIRECT AIR 0.255812
F3 NE APARTMENT DIRECT AIR 0.211032
F3 N1 APARTMENT DIRECT AIR 0.131725
F3 N2 APARTMENT DIRECT AIR 0.130226
F3 S1 APARTMENT DIRECT AIR 0.188013
F3 S2 APARTMENT DIRECT AIR 0.189236
F4 SW APARTMENT DIRECT AIR 0.279135
F4 NW APARTMENT DIRECT AIR 0.251045
F4 SE APARTMENT DIRECT AIR 0.254953
F4 NE APARTMENT DIRECT AIR 0.222077
F4 N1 APARTMENT DIRECT AIR 0.133080
F4 N2 APARTMENT DIRECT AIR 0.131586
F4 S1 APARTMENT DIRECT AIR 0.189255
F4 S2 APARTMENT DIRECT AIR 0.190282
M SW APARTMENT DIRECT AIR 0.281563
M NW APARTMENT DIRECT AIR 0.253763
M SE APARTMENT DIRECT AIR 0.257643
M NE APARTMENT DIRECT AIR 0.230794
M N1 APARTMENT DIRECT AIR 0.135898
M N2 APARTMENT DIRECT AIR 0.134507
M S1 APARTMENT DIRECT AIR 0.192026
M S2 APARTMENT DIRECT AIR 0.193025
F6 SW APARTMENT DIRECT AIR 0.278239
F6 NW APARTMENT DIRECT AIR 0.250466
F6 SE APARTMENT DIRECT AIR 0.254706
F6 NE APARTMENT DIRECT AIR 0.241462
F6 N1 APARTMENT DIRECT AIR 0.141680
F6 N2 APARTMENT DIRECT AIR 0.141666
F6 S1 APARTMENT DIRECT AIR 0.188980
F6 S2 APARTMENT DIRECT AIR 0.189977
F7 SW APARTMENT DIRECT AIR 0.277156
F7 NW APARTMENT DIRECT AIR 0.250708
F7 SE APARTMENT DIRECT AIR 0.253855
F7 NE APARTMENT DIRECT AIR 0.250010
F7 N1 APARTMENT DIRECT AIR 0.147187
F7 N2 APARTMENT DIRECT AIR 0.147172
F7 S1 APARTMENT DIRECT AIR 0.188002
F7 S2 APARTMENT DIRECT AIR 0.188997
F8 SW APARTMENT DIRECT AIR 0.277195
F8 NW APARTMENT DIRECT AIR 0.259051
F8 SE APARTMENT DIRECT AIR 0.257049
F8 NE APARTMENT DIRECT AIR 0.258295
F8 N1 APARTMENT DIRECT AIR 0.152742
F8 N2 APARTMENT DIRECT AIR 0.152725
F8 S1 APARTMENT DIRECT AIR 0.188114
F8 S2 APARTMENT DIRECT AIR 0.189112
F9 SW APARTMENT DIRECT AIR 0.284478
F9 NW APARTMENT DIRECT AIR 0.274327
F9 SE APARTMENT DIRECT AIR 0.272366
F9 NE APARTMENT DIRECT AIR 0.273511
F9 N1 APARTMENT DIRECT AIR 0.164906
F9 N2 APARTMENT DIRECT AIR 0.164888
F9 S1 APARTMENT DIRECT AIR 0.192437
F9 S2 APARTMENT DIRECT AIR 0.193499
T SW APARTMENT DIRECT AIR 0.341153
T NW APARTMENT DIRECT AIR 0.315821
T SE APARTMENT DIRECT AIR 0.313486
T NE APARTMENT DIRECT AIR 0.315021
T N1 APARTMENT DIRECT AIR 0.207738
T N2 APARTMENT DIRECT AIR 0.207719
T S1 APARTMENT DIRECT AIR 0.252502
T S2 APARTMENT DIRECT AIR 0.253492


Branch

Maximum Flow Rate [m3/s]
AIRLOOP G SW MAIN BRANCH 0.205722
AIRLOOP G NW MAIN BRANCH 0.204303
AIRLOOP OFFICE MAIN BRANCH 0.330758
AIRLOOP G NE MAIN BRANCH 0.204414
AIRLOOP G N1 MAIN BRANCH 0.140109
AIRLOOP G N2 MAIN BRANCH 0.140111
AIRLOOP G S1 MAIN BRANCH 0.139644
AIRLOOP G S2 MAIN BRANCH 0.139944
AIRLOOP F2 SW MAIN BRANCH 0.276460
AIRLOOP F2 NW MAIN BRANCH 0.246600
AIRLOOP F2 SE MAIN BRANCH 0.274256
AIRLOOP F2 NE MAIN BRANCH 0.202350
AIRLOOP F2 N1 MAIN BRANCH 0.127011
AIRLOOP F2 N2 MAIN BRANCH 0.125501
AIRLOOP F2 S1 MAIN BRANCH 0.183383
AIRLOOP F2 S2 MAIN BRANCH 0.185963
AIRLOOP F3 SW MAIN BRANCH 0.278474
AIRLOOP F3 NW MAIN BRANCH 0.250036
AIRLOOP F3 SE MAIN BRANCH 0.255812
AIRLOOP F3 NE MAIN BRANCH 0.211032
AIRLOOP F3 N1 MAIN BRANCH 0.131725
AIRLOOP F3 N2 MAIN BRANCH 0.130226
AIRLOOP F3 S1 MAIN BRANCH 0.188013
AIRLOOP F3 S2 MAIN BRANCH 0.189236
AIRLOOP F4 SW MAIN BRANCH 0.279135
AIRLOOP F4 NW MAIN BRANCH 0.251045
AIRLOOP F4 SE MAIN BRANCH 0.254953
AIRLOOP F4 NE MAIN BRANCH 0.222077
AIRLOOP F4 N1 MAIN BRANCH 0.133080
AIRLOOP F4 N2 MAIN BRANCH 0.131586
AIRLOOP F4 S1 MAIN BRANCH 0.189255
AIRLOOP F4 S2 MAIN BRANCH 0.190282
AIRLOOP M SW MAIN BRANCH 0.281563
AIRLOOP M NW MAIN BRANCH 0.253763
AIRLOOP M SE MAIN BRANCH 0.257643
AIRLOOP M NE MAIN BRANCH 0.230794
AIRLOOP M N1 MAIN BRANCH 0.135898
AIRLOOP M N2 MAIN BRANCH 0.134507
AIRLOOP M S1 MAIN BRANCH 0.192026
AIRLOOP M S2 MAIN BRANCH 0.193025
AIRLOOP F6 SW MAIN BRANCH 0.278239
AIRLOOP F6 NW MAIN BRANCH 0.250466
AIRLOOP F6 SE MAIN BRANCH 0.254706
AIRLOOP F6 NE MAIN BRANCH 0.241462
AIRLOOP F6 N1 MAIN BRANCH 0.141680
AIRLOOP F6 N2 MAIN BRANCH 0.141666
AIRLOOP F6 S1 MAIN BRANCH 0.188980
AIRLOOP F6 S2 MAIN BRANCH 0.189977
AIRLOOP F7 SW MAIN BRANCH 0.277156
AIRLOOP F7 NW MAIN BRANCH 0.250708
AIRLOOP F7 SE MAIN BRANCH 0.253855
AIRLOOP F7 NE MAIN BRANCH 0.250010
AIRLOOP F7 N1 MAIN BRANCH 0.147187
AIRLOOP F7 N2 MAIN BRANCH 0.147172
AIRLOOP F7 S1 MAIN BRANCH 0.188002
AIRLOOP F7 S2 MAIN BRANCH 0.188997
AIRLOOP F8 SW MAIN BRANCH 0.277195
AIRLOOP F8 NW MAIN BRANCH 0.259051
AIRLOOP F8 SE MAIN BRANCH 0.257049
AIRLOOP F8 NE MAIN BRANCH 0.258295
AIRLOOP F8 N1 MAIN BRANCH 0.152742
AIRLOOP F8 N2 MAIN BRANCH 0.152725
AIRLOOP F8 S1 MAIN BRANCH 0.188114
AIRLOOP F8 S2 MAIN BRANCH 0.189112
AIRLOOP F9 SW MAIN BRANCH 0.284478
AIRLOOP F9 NW MAIN BRANCH 0.274327
AIRLOOP F9 SE MAIN BRANCH 0.272366
AIRLOOP F9 NE MAIN BRANCH 0.273511
AIRLOOP F9 N1 MAIN BRANCH 0.164906
AIRLOOP F9 N2 MAIN BRANCH 0.164888
AIRLOOP F9 S1 MAIN BRANCH 0.192437
AIRLOOP F9 S2 MAIN BRANCH 0.193499
AIRLOOP T SW MAIN BRANCH 0.341153
AIRLOOP T NW MAIN BRANCH 0.315821
AIRLOOP T SE MAIN BRANCH 0.313486
AIRLOOP T NE MAIN BRANCH 0.315021
AIRLOOP T N1 MAIN BRANCH 0.207738
AIRLOOP T N2 MAIN BRANCH 0.207719
AIRLOOP T S1 MAIN BRANCH 0.252502
AIRLOOP T S2 MAIN BRANCH 0.253492


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
AIRLOOP G SW 0.205722
AIRLOOP G NW 0.204303
AIRLOOP OFFICE 0.330758
AIRLOOP G NE 0.204414
AIRLOOP G N1 0.140109
AIRLOOP G N2 0.140111
AIRLOOP G S1 0.139644
AIRLOOP G S2 0.139944
AIRLOOP F2 SW 0.276460
AIRLOOP F2 NW 0.246600
AIRLOOP F2 SE 0.274256
AIRLOOP F2 NE 0.202350
AIRLOOP F2 N1 0.127011
AIRLOOP F2 N2 0.125501
AIRLOOP F2 S1 0.183383
AIRLOOP F2 S2 0.185963
AIRLOOP F3 SW 0.278474
AIRLOOP F3 NW 0.250036
AIRLOOP F3 SE 0.255812
AIRLOOP F3 NE 0.211032
AIRLOOP F3 N1 0.131725
AIRLOOP F3 N2 0.130226
AIRLOOP F3 S1 0.188013
AIRLOOP F3 S2 0.189236
AIRLOOP F4 SW 0.279135
AIRLOOP F4 NW 0.251045
AIRLOOP F4 SE 0.254953
AIRLOOP F4 NE 0.222077
AIRLOOP F4 N1 0.133080
AIRLOOP F4 N2 0.131586
AIRLOOP F4 S1 0.189255
AIRLOOP F4 S2 0.190282
AIRLOOP M SW 0.281563
AIRLOOP M NW 0.253763
AIRLOOP M SE 0.257643
AIRLOOP M NE 0.230794
AIRLOOP M N1 0.135898
AIRLOOP M N2 0.134507
AIRLOOP M S1 0.192026
AIRLOOP M S2 0.193025
AIRLOOP F6 SW 0.278239
AIRLOOP F6 NW 0.250466
AIRLOOP F6 SE 0.254706
AIRLOOP F6 NE 0.241462
AIRLOOP F6 N1 0.141680
AIRLOOP F6 N2 0.141666
AIRLOOP F6 S1 0.188980
AIRLOOP F6 S2 0.189977
AIRLOOP F7 SW 0.277156
AIRLOOP F7 NW 0.250708
AIRLOOP F7 SE 0.253855
AIRLOOP F7 NE 0.250010
AIRLOOP F7 N1 0.147187
AIRLOOP F7 N2 0.147172
AIRLOOP F7 S1 0.188002
AIRLOOP F7 S2 0.188997
AIRLOOP F8 SW 0.277195
AIRLOOP F8 NW 0.259051
AIRLOOP F8 SE 0.257049
AIRLOOP F8 NE 0.258295
AIRLOOP F8 N1 0.152742
AIRLOOP F8 N2 0.152725
AIRLOOP F8 S1 0.188114
AIRLOOP F8 S2 0.189112
AIRLOOP F9 SW 0.284478
AIRLOOP F9 NW 0.274327
AIRLOOP F9 SE 0.272366
AIRLOOP F9 NE 0.273511
AIRLOOP F9 N1 0.164906
AIRLOOP F9 N2 0.164888
AIRLOOP F9 S1 0.192437
AIRLOOP F9 S2 0.193499
AIRLOOP T SW 0.341153
AIRLOOP T NW 0.315821
AIRLOOP T SE 0.313486
AIRLOOP T NE 0.315021
AIRLOOP T N1 0.207738
AIRLOOP T N2 0.207719
AIRLOOP T S1 0.252502
AIRLOOP T S2 0.253492


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
AIRLOOP G SW OA CONTROLLER 0.205722 0.025952
AIRLOOP G NW OA CONTROLLER 0.204303 0.025952
AIRLOOP OFFICE OA CONTROLLER 0.330758 0.038103
AIRLOOP G NE OA CONTROLLER 0.204414 0.025952
AIRLOOP G N1 OA CONTROLLER 0.140109 0.025952
AIRLOOP G N2 OA CONTROLLER 0.140111 0.025952
AIRLOOP G S1 OA CONTROLLER 0.139644 0.025952
AIRLOOP G S2 OA CONTROLLER 0.139944 0.025952
AIRLOOP F2 SW OA CONTROLLER 0.276460 0.025952
AIRLOOP F2 NW OA CONTROLLER 0.246600 0.025952
AIRLOOP F2 SE OA CONTROLLER 0.274256 0.025952
AIRLOOP F2 NE OA CONTROLLER 0.202350 0.025952
AIRLOOP F2 N1 OA CONTROLLER 0.127011 0.025952
AIRLOOP F2 N2 OA CONTROLLER 0.125501 0.025952
AIRLOOP F2 S1 OA CONTROLLER 0.183383 0.025952
AIRLOOP F2 S2 OA CONTROLLER 0.185963 0.025952
AIRLOOP F3 SW OA CONTROLLER 0.278474 0.025952
AIRLOOP F3 NW OA CONTROLLER 0.250036 0.025952
AIRLOOP F3 SE OA CONTROLLER 0.255812 0.025952
AIRLOOP F3 NE OA CONTROLLER 0.211032 0.025952
AIRLOOP F3 N1 OA CONTROLLER 0.131725 0.025952
AIRLOOP F3 N2 OA CONTROLLER 0.130226 0.025952
AIRLOOP F3 S1 OA CONTROLLER 0.188013 0.025952
AIRLOOP F3 S2 OA CONTROLLER 0.189236 0.025952
AIRLOOP F4 SW OA CONTROLLER 0.279135 0.025952
AIRLOOP F4 NW OA CONTROLLER 0.251045 0.025952
AIRLOOP F4 SE OA CONTROLLER 0.254953 0.025952
AIRLOOP F4 NE OA CONTROLLER 0.222077 0.025952
AIRLOOP F4 N1 OA CONTROLLER 0.133080 0.025952
AIRLOOP F4 N2 OA CONTROLLER 0.131586 0.025952
AIRLOOP F4 S1 OA CONTROLLER 0.189255 0.025952
AIRLOOP F4 S2 OA CONTROLLER 0.190282 0.025952
AIRLOOP M SW OA CONTROLLER 0.281563 0.025952
AIRLOOP M NW OA CONTROLLER 0.253763 0.025952
AIRLOOP M SE OA CONTROLLER 0.257643 0.025952
AIRLOOP M NE OA CONTROLLER 0.230794 0.025952
AIRLOOP M N1 OA CONTROLLER 0.135898 0.025952
AIRLOOP M N2 OA CONTROLLER 0.134507 0.025952
AIRLOOP M S1 OA CONTROLLER 0.192026 0.025952
AIRLOOP M S2 OA CONTROLLER 0.193025 0.025952
AIRLOOP F6 SW OA CONTROLLER 0.278239 0.025952
AIRLOOP F6 NW OA CONTROLLER 0.250466 0.025952
AIRLOOP F6 SE OA CONTROLLER 0.254706 0.025952
AIRLOOP F6 NE OA CONTROLLER 0.241462 0.025952
AIRLOOP F6 N1 OA CONTROLLER 0.141680 0.025952
AIRLOOP F6 N2 OA CONTROLLER 0.141666 0.025952
AIRLOOP F6 S1 OA CONTROLLER 0.188980 0.025952
AIRLOOP F6 S2 OA CONTROLLER 0.189977 0.025952
AIRLOOP F7 SW OA CONTROLLER 0.277156 0.025952
AIRLOOP F7 NW OA CONTROLLER 0.250708 0.025952
AIRLOOP F7 SE OA CONTROLLER 0.253855 0.025952
AIRLOOP F7 NE OA CONTROLLER 0.250010 0.025952
AIRLOOP F7 N1 OA CONTROLLER 0.147187 0.025952
AIRLOOP F7 N2 OA CONTROLLER 0.147172 0.025952
AIRLOOP F7 S1 OA CONTROLLER 0.188002 0.025952
AIRLOOP F7 S2 OA CONTROLLER 0.188997 0.025952
AIRLOOP F8 SW OA CONTROLLER 0.277195 0.025952
AIRLOOP F8 NW OA CONTROLLER 0.259051 0.025952
AIRLOOP F8 SE OA CONTROLLER 0.257049 0.025952
AIRLOOP F8 NE OA CONTROLLER 0.258295 0.025952
AIRLOOP F8 N1 OA CONTROLLER 0.152742 0.025952
AIRLOOP F8 N2 OA CONTROLLER 0.152725 0.025952
AIRLOOP F8 S1 OA CONTROLLER 0.188114 0.025952
AIRLOOP F8 S2 OA CONTROLLER 0.189112 0.025952
AIRLOOP F9 SW OA CONTROLLER 0.284478 0.025952
AIRLOOP F9 NW OA CONTROLLER 0.274327 0.025952
AIRLOOP F9 SE OA CONTROLLER 0.272366 0.025952
AIRLOOP F9 NE OA CONTROLLER 0.273511 0.025952
AIRLOOP F9 N1 OA CONTROLLER 0.164906 0.025952
AIRLOOP F9 N2 OA CONTROLLER 0.164888 0.025952
AIRLOOP F9 S1 OA CONTROLLER 0.192437 0.025952
AIRLOOP F9 S2 OA CONTROLLER 0.193499 0.025952
AIRLOOP T SW OA CONTROLLER 0.341153 0.025952
AIRLOOP T NW OA CONTROLLER 0.315821 0.025952
AIRLOOP T SE OA CONTROLLER 0.313486 0.025952
AIRLOOP T NE OA CONTROLLER 0.315021 0.025952
AIRLOOP T N1 OA CONTROLLER 0.207738 0.025952
AIRLOOP T N2 OA CONTROLLER 0.207719 0.025952
AIRLOOP T S1 OA CONTROLLER 0.252502 0.025952
AIRLOOP T S2 OA CONTROLLER 0.253492 0.025952


COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity [W] Rated Sensible Cooling Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP COOLING MODE AIRLOOP G SW 0.205722 3494.72 2266.68 0.000076
HEAT PUMP COOLING MODE AIRLOOP G NW 0.204303 3510.52 2253.89 0.000077
HEAT PUMP COOLING MODE AIRLOOP OFFICE 0.330758 5429.48 3594.63 0.000119
HEAT PUMP COOLING MODE AIRLOOP G NE 0.204414 3735.54 2316.37 0.000082
HEAT PUMP COOLING MODE AIRLOOP G N1 0.140109 2734.62 1641.03 0.000060
HEAT PUMP COOLING MODE AIRLOOP G N2 0.140111 2748.65 1645.72 0.000060
HEAT PUMP COOLING MODE AIRLOOP G S1 0.139644 2553.60 1601.76 0.000056
HEAT PUMP COOLING MODE AIRLOOP G S2 0.139944 2529.13 1595.37 0.000055
HEAT PUMP COOLING MODE AIRLOOP F2 SW 0.276460 4535.68 2987.25 0.000099
HEAT PUMP COOLING MODE AIRLOOP F2 NW 0.246600 4106.48 2677.26 0.000090
HEAT PUMP COOLING MODE AIRLOOP F2 SE 0.274256 4544.68 2986.41 0.000099
HEAT PUMP COOLING MODE AIRLOOP F2 NE 0.202350 3520.63 2237.83 0.000077
HEAT PUMP COOLING MODE AIRLOOP F2 N1 0.127011 2311.88 1433.75 0.000051
HEAT PUMP COOLING MODE AIRLOOP F2 N2 0.125501 2290.15 1418.48 0.000050
HEAT PUMP COOLING MODE AIRLOOP F2 S1 0.183383 3179.81 2044.87 0.000069
HEAT PUMP COOLING MODE AIRLOOP F2 S2 0.185963 3215.43 2070.74 0.000070
HEAT PUMP COOLING MODE AIRLOOP F3 SW 0.278474 4615.28 3021.57 0.000101
HEAT PUMP COOLING MODE AIRLOOP F3 NW 0.250036 4214.15 2730.82 0.000092
HEAT PUMP COOLING MODE AIRLOOP F3 SE 0.255812 4339.47 2814.85 0.000095
HEAT PUMP COOLING MODE AIRLOOP F3 NE 0.211032 3707.02 2343.93 0.000081
HEAT PUMP COOLING MODE AIRLOOP F3 N1 0.131725 2404.18 1488.82 0.000053
HEAT PUMP COOLING MODE AIRLOOP F3 N2 0.130226 2382.52 1473.64 0.000052
HEAT PUMP COOLING MODE AIRLOOP F3 S1 0.188013 3273.79 2099.72 0.000072
HEAT PUMP COOLING MODE AIRLOOP F3 S2 0.189236 3290.67 2111.98 0.000072
HEAT PUMP COOLING MODE AIRLOOP F4 SW 0.279135 4662.50 3038.66 0.000102
HEAT PUMP COOLING MODE AIRLOOP F4 NW 0.251045 4264.62 2751.14 0.000093
HEAT PUMP COOLING MODE AIRLOOP F4 SE 0.254953 4364.16 2816.41 0.000095
HEAT PUMP COOLING MODE AIRLOOP F4 NE 0.222077 3937.18 2477.15 0.000086
HEAT PUMP COOLING MODE AIRLOOP F4 N1 0.133080 2441.97 1508.07 0.000053
HEAT PUMP COOLING MODE AIRLOOP F4 N2 0.131586 2420.29 1492.93 0.000053
HEAT PUMP COOLING MODE AIRLOOP F4 S1 0.189255 3313.17 2118.44 0.000072
HEAT PUMP COOLING MODE AIRLOOP F4 S2 0.190282 3327.37 2128.73 0.000073
HEAT PUMP COOLING MODE AIRLOOP M SW 0.281563 4727.00 3071.57 0.000103
HEAT PUMP COOLING MODE AIRLOOP M NW 0.253763 4331.99 2786.74 0.000095
HEAT PUMP COOLING MODE AIRLOOP M SE 0.257643 4431.34 2851.77 0.000097
HEAT PUMP COOLING MODE AIRLOOP M NE 0.230794 4113.64 2580.76 0.000090
HEAT PUMP COOLING MODE AIRLOOP M N1 0.135898 2497.40 1541.08 0.000055
HEAT PUMP COOLING MODE AIRLOOP M N2 0.134507 2477.54 1527.09 0.000054
HEAT PUMP COOLING MODE AIRLOOP M S1 0.192026 3369.75 2151.38 0.000074
HEAT PUMP COOLING MODE AIRLOOP M S2 0.193025 3383.58 2161.40 0.000074
HEAT PUMP COOLING MODE AIRLOOP F6 SW 0.278239 4724.80 3056.08 0.000103
HEAT PUMP COOLING MODE AIRLOOP F6 NW 0.250466 4310.11 2760.44 0.000094
HEAT PUMP COOLING MODE AIRLOOP F6 SE 0.254706 4414.82 2829.13 0.000096
HEAT PUMP COOLING MODE AIRLOOP F6 NE 0.241462 4357.64 2719.10 0.000095
HEAT PUMP COOLING MODE AIRLOOP F6 N1 0.141680 2628.86 1614.47 0.000057
HEAT PUMP COOLING MODE AIRLOOP F6 N2 0.141666 2634.80 1616.26 0.000058
HEAT PUMP COOLING MODE AIRLOOP F6 S1 0.188980 3342.16 2125.01 0.000073
HEAT PUMP COOLING MODE AIRLOOP F6 S2 0.189977 3355.99 2135.01 0.000073
HEAT PUMP COOLING MODE AIRLOOP F7 SW 0.277156 4731.90 3051.39 0.000103
HEAT PUMP COOLING MODE AIRLOOP F7 NW 0.250708 4338.99 2770.20 0.000095
HEAT PUMP COOLING MODE AIRLOOP F7 SE 0.253855 4424.29 2826.63 0.000097
HEAT PUMP COOLING MODE AIRLOOP F7 NE 0.250010 4542.98 2824.74 0.000099
HEAT PUMP COOLING MODE AIRLOOP F7 N1 0.147187 2746.72 1682.11 0.000060
HEAT PUMP COOLING MODE AIRLOOP F7 N2 0.147172 2752.95 1684.00 0.000060
HEAT PUMP COOLING MODE AIRLOOP F7 S1 0.188002 3341.47 2118.90 0.000073
HEAT PUMP COOLING MODE AIRLOOP F7 S2 0.188997 3355.33 2128.89 0.000073
HEAT PUMP COOLING MODE AIRLOOP F8 SW 0.277195 4752.25 3057.35 0.000104
HEAT PUMP COOLING MODE AIRLOOP F8 NW 0.259051 4502.70 2867.92 0.000098
HEAT PUMP COOLING MODE AIRLOOP F8 SE 0.257049 4498.51 2867.45 0.000098
HEAT PUMP COOLING MODE AIRLOOP F8 NE 0.258295 4717.07 2925.45 0.000103
HEAT PUMP COOLING MODE AIRLOOP F8 N1 0.152742 2859.93 1748.56 0.000062
HEAT PUMP COOLING MODE AIRLOOP F8 N2 0.152725 2866.33 1750.50 0.000063
HEAT PUMP COOLING MODE AIRLOOP F8 S1 0.188114 3354.68 2123.37 0.000073
HEAT PUMP COOLING MODE AIRLOOP F8 S2 0.189112 3368.59 2133.39 0.000074
HEAT PUMP COOLING MODE AIRLOOP F9 SW 0.284478 4854.53 3125.15 0.000106
HEAT PUMP COOLING MODE AIRLOOP F9 NW 0.274327 4762.06 3034.87 0.000104
HEAT PUMP COOLING MODE AIRLOOP F9 SE 0.272366 4768.51 3039.08 0.000104
HEAT PUMP COOLING MODE AIRLOOP F9 NE 0.273511 5004.16 3100.42 0.000109
HEAT PUMP COOLING MODE AIRLOOP F9 N1 0.164906 3067.86 1881.47 0.000067
HEAT PUMP COOLING MODE AIRLOOP F9 N2 0.164888 3074.38 1883.43 0.000067
HEAT PUMP COOLING MODE AIRLOOP F9 S1 0.192437 3428.79 2171.46 0.000075
HEAT PUMP COOLING MODE AIRLOOP F9 S2 0.193499 3441.45 2180.80 0.000075
HEAT PUMP COOLING MODE AIRLOOP T SW 0.341153 5702.34 3721.46 0.000125
HEAT PUMP COOLING MODE AIRLOOP T NW 0.315821 5362.38 3461.01 0.000117
HEAT PUMP COOLING MODE AIRLOOP T SE 0.313486 5332.29 3448.08 0.000116
HEAT PUMP COOLING MODE AIRLOOP T NE 0.315021 5603.29 3524.05 0.000122
HEAT PUMP COOLING MODE AIRLOOP T N1 0.207738 3839.49 2388.13 0.000084
HEAT PUMP COOLING MODE AIRLOOP T N2 0.207719 3845.33 2390.75 0.000084
HEAT PUMP COOLING MODE AIRLOOP T S1 0.252502 4277.30 2777.85 0.000093
HEAT PUMP COOLING MODE AIRLOOP T S2 0.253492 4290.87 2787.76 0.000094


AirLoopHVAC:UnitaryHeatPump:WaterToAir

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Supplemental Heating Coil Nominal Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
AIRLOOP G SW DXAC HEAT PUMP 0.205722 0.205722 0.205722 0.205722 3494.72 3494.72 5790.18 1.00
AIRLOOP G NW DXAC HEAT PUMP 0.204303 0.204303 0.204303 0.204303 3510.52 3510.52 5797.70 1.00
AIRLOOP OFFICE DXAC HEAT PUMP 0.330758 0.330758 0.330758 0.330758 5429.48 5429.48 6934.29 1.00
AIRLOOP G NE DXAC HEAT PUMP 0.204414 0.204414 0.204414 0.204414 3735.54 3735.54 5800.02 1.00
AIRLOOP G N1 DXAC HEAT PUMP 0.140109 0.140109 0.140109 0.140109 2734.62 2734.62 4447.31 1.00
AIRLOOP G N2 DXAC HEAT PUMP 0.140111 0.140111 0.140111 0.140111 2748.65 2748.65 4447.35 1.00
AIRLOOP G S1 DXAC HEAT PUMP 0.139644 0.139644 0.139644 0.139644 2553.60 2553.60 4437.51 1.00
AIRLOOP G S2 DXAC HEAT PUMP 0.139944 0.139944 0.139944 0.139944 2529.13 2529.13 4443.83 1.00
AIRLOOP F2 SW DXAC HEAT PUMP 0.276460 0.276460 0.276460 0.276460 4535.68 4535.68 5756.77 1.00
AIRLOOP F2 NW DXAC HEAT PUMP 0.246600 0.246600 0.246600 0.246600 4106.48 4106.48 5760.11 1.00
AIRLOOP F2 SE DXAC HEAT PUMP 0.274256 0.274256 0.274256 0.274256 4544.68 4544.68 5771.78 1.00
AIRLOOP F2 NE DXAC HEAT PUMP 0.202350 0.202350 0.202350 0.202350 3520.63 3520.63 5757.17 1.00
AIRLOOP F2 N1 DXAC HEAT PUMP 0.127011 0.127011 0.127011 0.127011 2311.88 2311.88 4049.99 1.00
AIRLOOP F2 N2 DXAC HEAT PUMP 0.125501 0.125501 0.125501 0.125501 2290.15 2290.15 4049.93 1.00
AIRLOOP F2 S1 DXAC HEAT PUMP 0.183383 0.183383 0.183383 0.183383 3179.81 3179.81 4049.80 1.00
AIRLOOP F2 S2 DXAC HEAT PUMP 0.185963 0.185963 0.185963 0.185963 3215.43 3215.43 4050.82 1.00
AIRLOOP F3 SW DXAC HEAT PUMP 0.278474 0.278474 0.278474 0.278474 4615.28 4615.28 5934.99 1.00
AIRLOOP F3 NW DXAC HEAT PUMP 0.250036 0.250036 0.250036 0.250036 4214.15 4214.15 5946.68 1.00
AIRLOOP F3 SE DXAC HEAT PUMP 0.255812 0.255812 0.255812 0.255812 4339.47 4339.47 5930.08 1.00
AIRLOOP F3 NE DXAC HEAT PUMP 0.211032 0.211032 0.211032 0.211032 3707.02 3707.02 5939.98 1.00
AIRLOOP F3 N1 DXAC HEAT PUMP 0.131725 0.131725 0.131725 0.131725 2404.18 2404.18 4101.16 1.00
AIRLOOP F3 N2 DXAC HEAT PUMP 0.130226 0.130226 0.130226 0.130226 2382.52 2382.52 4101.01 1.00
AIRLOOP F3 S1 DXAC HEAT PUMP 0.188013 0.188013 0.188013 0.188013 3273.79 3273.79 4090.68 1.00
AIRLOOP F3 S2 DXAC HEAT PUMP 0.189236 0.189236 0.189236 0.189236 3290.67 3290.67 4090.69 1.00
AIRLOOP F4 SW DXAC HEAT PUMP 0.279135 0.279135 0.279135 0.279135 4662.50 4662.50 6165.08 1.00
AIRLOOP F4 NW DXAC HEAT PUMP 0.251045 0.251045 0.251045 0.251045 4264.62 4264.62 6181.89 1.00
AIRLOOP F4 SE DXAC HEAT PUMP 0.254953 0.254953 0.254953 0.254953 4364.16 4364.16 6155.84 1.00
AIRLOOP F4 NE DXAC HEAT PUMP 0.222077 0.222077 0.222077 0.222077 3937.18 3937.18 6172.48 1.00
AIRLOOP F4 N1 DXAC HEAT PUMP 0.133080 0.133080 0.133080 0.133080 2441.97 2441.97 4230.13 1.00
AIRLOOP F4 N2 DXAC HEAT PUMP 0.131586 0.131586 0.131586 0.131586 2420.29 2420.29 4229.93 1.00
AIRLOOP F4 S1 DXAC HEAT PUMP 0.189255 0.189255 0.189255 0.189255 3313.17 3313.17 4214.22 1.00
AIRLOOP F4 S2 DXAC HEAT PUMP 0.190282 0.190282 0.190282 0.190282 3327.37 3327.37 4214.03 1.00
AIRLOOP M SW DXAC HEAT PUMP 0.281563 0.281563 0.281563 0.281563 4727.00 4727.00 6348.25 1.00
AIRLOOP M NW DXAC HEAT PUMP 0.253763 0.253763 0.253763 0.253763 4331.99 4331.99 6367.52 1.00
AIRLOOP M SE DXAC HEAT PUMP 0.257643 0.257643 0.257643 0.257643 4431.34 4431.34 6336.76 1.00
AIRLOOP M NE DXAC HEAT PUMP 0.230794 0.230794 0.230794 0.230794 4113.64 4113.64 6356.00 1.00
AIRLOOP M N1 DXAC HEAT PUMP 0.135898 0.135898 0.135898 0.135898 2497.40 2497.40 4330.10 1.00
AIRLOOP M N2 DXAC HEAT PUMP 0.134507 0.134507 0.134507 0.134507 2477.54 2477.54 4329.84 1.00
AIRLOOP M S1 DXAC HEAT PUMP 0.192026 0.192026 0.192026 0.192026 3369.75 3369.75 4311.63 1.00
AIRLOOP M S2 DXAC HEAT PUMP 0.193025 0.193025 0.193025 0.193025 3383.58 3383.58 4311.38 1.00
AIRLOOP F6 SW DXAC HEAT PUMP 0.278239 0.278239 0.278239 0.278239 4724.80 4724.80 6570.94 1.00
AIRLOOP F6 NW DXAC HEAT PUMP 0.250466 0.250466 0.250466 0.250466 4310.11 4310.11 6593.79 1.00
AIRLOOP F6 SE DXAC HEAT PUMP 0.254706 0.254706 0.254706 0.254706 4414.82 4414.82 6557.70 1.00
AIRLOOP F6 NE DXAC HEAT PUMP 0.241462 0.241462 0.241462 0.241462 4357.64 4357.64 6580.55 1.00
AIRLOOP F6 N1 DXAC HEAT PUMP 0.141680 0.141680 0.141680 0.141680 2628.86 2628.86 4480.77 1.00
AIRLOOP F6 N2 DXAC HEAT PUMP 0.141666 0.141666 0.141666 0.141666 2634.80 2634.80 4480.48 1.00
AIRLOOP F6 S1 DXAC HEAT PUMP 0.188980 0.188980 0.188980 0.188980 3342.16 3342.16 4458.67 1.00
AIRLOOP F6 S2 DXAC HEAT PUMP 0.189977 0.189977 0.189977 0.189977 3355.99 3355.99 4458.38 1.00
AIRLOOP F7 SW DXAC HEAT PUMP 0.277156 0.277156 0.277156 0.277156 4731.90 4731.90 6750.30 1.00
AIRLOOP F7 NW DXAC HEAT PUMP 0.250708 0.250708 0.250708 0.250708 4338.99 4338.99 6775.17 1.00
AIRLOOP F7 SE DXAC HEAT PUMP 0.253855 0.253855 0.253855 0.253855 4424.29 4424.29 6735.63 1.00
AIRLOOP F7 NE DXAC HEAT PUMP 0.250010 0.250010 0.250010 0.250010 4542.98 4542.98 6760.49 1.00
AIRLOOP F7 N1 DXAC HEAT PUMP 0.147187 0.147187 0.147187 0.147187 2746.72 2746.72 4596.67 1.00
AIRLOOP F7 N2 DXAC HEAT PUMP 0.147172 0.147172 0.147172 0.147172 2752.95 2752.95 4596.35 1.00
AIRLOOP F7 S1 DXAC HEAT PUMP 0.188002 0.188002 0.188002 0.188002 3341.47 3341.47 4572.53 1.00
AIRLOOP F7 S2 DXAC HEAT PUMP 0.188997 0.188997 0.188997 0.188997 3355.33 3355.33 4572.21 1.00
AIRLOOP F8 SW DXAC HEAT PUMP 0.277195 0.277195 0.277195 0.277195 4752.25 4752.25 6924.59 1.00
AIRLOOP F8 NW DXAC HEAT PUMP 0.259051 0.259051 0.259051 0.259051 4502.70 4502.70 6950.81 1.00
AIRLOOP F8 SE DXAC HEAT PUMP 0.257049 0.257049 0.257049 0.257049 4498.51 4498.51 6908.67 1.00
AIRLOOP F8 NE DXAC HEAT PUMP 0.258295 0.258295 0.258295 0.258295 4717.07 4717.07 6934.89 1.00
AIRLOOP F8 N1 DXAC HEAT PUMP 0.152742 0.152742 0.152742 0.152742 2859.93 2859.93 4713.56 1.00
AIRLOOP F8 N2 DXAC HEAT PUMP 0.152725 0.152725 0.152725 0.152725 2866.33 2866.33 4713.21 1.00
AIRLOOP F8 S1 DXAC HEAT PUMP 0.188114 0.188114 0.188114 0.188114 3354.68 3354.68 4688.06 1.00
AIRLOOP F8 S2 DXAC HEAT PUMP 0.189112 0.189112 0.189112 0.189112 3368.59 3368.59 4687.71 1.00
AIRLOOP F9 SW DXAC HEAT PUMP 0.284478 0.284478 0.284478 0.284478 4854.53 4854.53 7248.20 1.00
AIRLOOP F9 NW DXAC HEAT PUMP 0.274327 0.274327 0.274327 0.274327 4762.06 4762.06 7272.28 1.00
AIRLOOP F9 SE DXAC HEAT PUMP 0.272366 0.272366 0.272366 0.272366 4768.51 4768.51 7231.03 1.00
AIRLOOP F9 NE DXAC HEAT PUMP 0.273511 0.273511 0.273511 0.273511 5004.16 5004.16 7255.12 1.00
AIRLOOP F9 N1 DXAC HEAT PUMP 0.164906 0.164906 0.164906 0.164906 3067.86 3067.86 4969.48 1.00
AIRLOOP F9 N2 DXAC HEAT PUMP 0.164888 0.164888 0.164888 0.164888 3074.38 3074.38 4969.10 1.00
AIRLOOP F9 S1 DXAC HEAT PUMP 0.192437 0.192437 0.192437 0.192437 3428.79 3428.79 4945.66 1.00
AIRLOOP F9 S2 DXAC HEAT PUMP 0.193499 0.193499 0.193499 0.193499 3441.45 3441.45 4945.28 1.00
AIRLOOP T SW DXAC HEAT PUMP 0.341153 0.341153 0.341153 0.341153 5702.34 5702.34 8113.34 1.00
AIRLOOP T NW DXAC HEAT PUMP 0.315821 0.315821 0.315821 0.315821 5362.38 5362.38 8145.63 1.00
AIRLOOP T SE DXAC HEAT PUMP 0.313486 0.313486 0.313486 0.313486 5332.29 5332.29 8096.51 1.00
AIRLOOP T NE DXAC HEAT PUMP 0.315021 0.315021 0.315021 0.315021 5603.29 5603.29 8128.80 1.00
AIRLOOP T N1 DXAC HEAT PUMP 0.207738 0.207738 0.207738 0.207738 3839.49 3839.49 5870.68 1.00
AIRLOOP T N2 DXAC HEAT PUMP 0.207719 0.207719 0.207719 0.207719 3845.33 3845.33 5870.29 1.00
AIRLOOP T S1 DXAC HEAT PUMP 0.252502 0.252502 0.252502 0.252502 4277.30 4277.30 5835.47 1.00
AIRLOOP T S2 DXAC HEAT PUMP 0.253492 0.253492 0.253492 0.253492 4290.87 4290.87 5835.08 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
AIRLOOP G SW SUPPLY FAN 0.205722
AIRLOOP G NW SUPPLY FAN 0.204303
AIRLOOP OFFICE SUPPLY FAN 0.330758
AIRLOOP G NE SUPPLY FAN 0.204414
AIRLOOP G N1 SUPPLY FAN 0.140109
AIRLOOP G N2 SUPPLY FAN 0.140111
AIRLOOP G S1 SUPPLY FAN 0.139644
AIRLOOP G S2 SUPPLY FAN 0.139944
AIRLOOP F2 SW SUPPLY FAN 0.276460
AIRLOOP F2 NW SUPPLY FAN 0.246600
AIRLOOP F2 SE SUPPLY FAN 0.274256
AIRLOOP F2 NE SUPPLY FAN 0.202350
AIRLOOP F2 N1 SUPPLY FAN 0.127011
AIRLOOP F2 N2 SUPPLY FAN 0.125501
AIRLOOP F2 S1 SUPPLY FAN 0.183383
AIRLOOP F2 S2 SUPPLY FAN 0.185963
AIRLOOP F3 SW SUPPLY FAN 0.278474
AIRLOOP F3 NW SUPPLY FAN 0.250036
AIRLOOP F3 SE SUPPLY FAN 0.255812
AIRLOOP F3 NE SUPPLY FAN 0.211032
AIRLOOP F3 N1 SUPPLY FAN 0.131725
AIRLOOP F3 N2 SUPPLY FAN 0.130226
AIRLOOP F3 S1 SUPPLY FAN 0.188013
AIRLOOP F3 S2 SUPPLY FAN 0.189236
AIRLOOP F4 SW SUPPLY FAN 0.279135
AIRLOOP F4 NW SUPPLY FAN 0.251045
AIRLOOP F4 SE SUPPLY FAN 0.254953
AIRLOOP F4 NE SUPPLY FAN 0.222077
AIRLOOP F4 N1 SUPPLY FAN 0.133080
AIRLOOP F4 N2 SUPPLY FAN 0.131586
AIRLOOP F4 S1 SUPPLY FAN 0.189255
AIRLOOP F4 S2 SUPPLY FAN 0.190282
AIRLOOP M SW SUPPLY FAN 0.281563
AIRLOOP M NW SUPPLY FAN 0.253763
AIRLOOP M SE SUPPLY FAN 0.257643
AIRLOOP M NE SUPPLY FAN 0.230794
AIRLOOP M N1 SUPPLY FAN 0.135898
AIRLOOP M N2 SUPPLY FAN 0.134507
AIRLOOP M S1 SUPPLY FAN 0.192026
AIRLOOP M S2 SUPPLY FAN 0.193025
AIRLOOP F6 SW SUPPLY FAN 0.278239
AIRLOOP F6 NW SUPPLY FAN 0.250466
AIRLOOP F6 SE SUPPLY FAN 0.254706
AIRLOOP F6 NE SUPPLY FAN 0.241462
AIRLOOP F6 N1 SUPPLY FAN 0.141680
AIRLOOP F6 N2 SUPPLY FAN 0.141666
AIRLOOP F6 S1 SUPPLY FAN 0.188980
AIRLOOP F6 S2 SUPPLY FAN 0.189977
AIRLOOP F7 SW SUPPLY FAN 0.277156
AIRLOOP F7 NW SUPPLY FAN 0.250708
AIRLOOP F7 SE SUPPLY FAN 0.253855
AIRLOOP F7 NE SUPPLY FAN 0.250010
AIRLOOP F7 N1 SUPPLY FAN 0.147187
AIRLOOP F7 N2 SUPPLY FAN 0.147172
AIRLOOP F7 S1 SUPPLY FAN 0.188002
AIRLOOP F7 S2 SUPPLY FAN 0.188997
AIRLOOP F8 SW SUPPLY FAN 0.277195
AIRLOOP F8 NW SUPPLY FAN 0.259051
AIRLOOP F8 SE SUPPLY FAN 0.257049
AIRLOOP F8 NE SUPPLY FAN 0.258295
AIRLOOP F8 N1 SUPPLY FAN 0.152742
AIRLOOP F8 N2 SUPPLY FAN 0.152725
AIRLOOP F8 S1 SUPPLY FAN 0.188114
AIRLOOP F8 S2 SUPPLY FAN 0.189112
AIRLOOP F9 SW SUPPLY FAN 0.284478
AIRLOOP F9 NW SUPPLY FAN 0.274327
AIRLOOP F9 SE SUPPLY FAN 0.272366
AIRLOOP F9 NE SUPPLY FAN 0.273511
AIRLOOP F9 N1 SUPPLY FAN 0.164906
AIRLOOP F9 N2 SUPPLY FAN 0.164888
AIRLOOP F9 S1 SUPPLY FAN 0.192437
AIRLOOP F9 S2 SUPPLY FAN 0.193499
AIRLOOP T SW SUPPLY FAN 0.341153
AIRLOOP T NW SUPPLY FAN 0.315821
AIRLOOP T SE SUPPLY FAN 0.313486
AIRLOOP T NE SUPPLY FAN 0.315021
AIRLOOP T N1 SUPPLY FAN 0.207738
AIRLOOP T N2 SUPPLY FAN 0.207719
AIRLOOP T S1 SUPPLY FAN 0.252502
AIRLOOP T S2 SUPPLY FAN 0.253492


COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Heating Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP HEATING MODE AIRLOOP G SW 0.205722 3494.72 0.000076
HEAT PUMP HEATING MODE AIRLOOP G NW 0.204303 3510.52 0.000077
HEAT PUMP HEATING MODE AIRLOOP OFFICE 0.330758 5429.48 0.000119
HEAT PUMP HEATING MODE AIRLOOP G NE 0.204414 3735.54 0.000082
HEAT PUMP HEATING MODE AIRLOOP G N1 0.140109 2734.62 0.000060
HEAT PUMP HEATING MODE AIRLOOP G N2 0.140111 2748.65 0.000060
HEAT PUMP HEATING MODE AIRLOOP G S1 0.139644 2553.60 0.000056
HEAT PUMP HEATING MODE AIRLOOP G S2 0.139944 2529.13 0.000055
HEAT PUMP HEATING MODE AIRLOOP F2 SW 0.276460 4535.68 0.000099
HEAT PUMP HEATING MODE AIRLOOP F2 NW 0.246600 4106.48 0.000090
HEAT PUMP HEATING MODE AIRLOOP F2 SE 0.274256 4544.68 0.000099
HEAT PUMP HEATING MODE AIRLOOP F2 NE 0.202350 3520.63 0.000077
HEAT PUMP HEATING MODE AIRLOOP F2 N1 0.127011 2311.88 0.000051
HEAT PUMP HEATING MODE AIRLOOP F2 N2 0.125501 2290.15 0.000050
HEAT PUMP HEATING MODE AIRLOOP F2 S1 0.183383 3179.81 0.000069
HEAT PUMP HEATING MODE AIRLOOP F2 S2 0.185963 3215.43 0.000070
HEAT PUMP HEATING MODE AIRLOOP F3 SW 0.278474 4615.28 0.000101
HEAT PUMP HEATING MODE AIRLOOP F3 NW 0.250036 4214.15 0.000092
HEAT PUMP HEATING MODE AIRLOOP F3 SE 0.255812 4339.47 0.000095
HEAT PUMP HEATING MODE AIRLOOP F3 NE 0.211032 3707.02 0.000081
HEAT PUMP HEATING MODE AIRLOOP F3 N1 0.131725 2404.18 0.000053
HEAT PUMP HEATING MODE AIRLOOP F3 N2 0.130226 2382.52 0.000052
HEAT PUMP HEATING MODE AIRLOOP F3 S1 0.188013 3273.79 0.000072
HEAT PUMP HEATING MODE AIRLOOP F3 S2 0.189236 3290.67 0.000072
HEAT PUMP HEATING MODE AIRLOOP F4 SW 0.279135 4662.50 0.000102
HEAT PUMP HEATING MODE AIRLOOP F4 NW 0.251045 4264.62 0.000093
HEAT PUMP HEATING MODE AIRLOOP F4 SE 0.254953 4364.16 0.000095
HEAT PUMP HEATING MODE AIRLOOP F4 NE 0.222077 3937.18 0.000086
HEAT PUMP HEATING MODE AIRLOOP F4 N1 0.133080 2441.97 0.000053
HEAT PUMP HEATING MODE AIRLOOP F4 N2 0.131586 2420.29 0.000053
HEAT PUMP HEATING MODE AIRLOOP F4 S1 0.189255 3313.17 0.000072
HEAT PUMP HEATING MODE AIRLOOP F4 S2 0.190282 3327.37 0.000073
HEAT PUMP HEATING MODE AIRLOOP M SW 0.281563 4727.00 0.000103
HEAT PUMP HEATING MODE AIRLOOP M NW 0.253763 4331.99 0.000095
HEAT PUMP HEATING MODE AIRLOOP M SE 0.257643 4431.34 0.000097
HEAT PUMP HEATING MODE AIRLOOP M NE 0.230794 4113.64 0.000090
HEAT PUMP HEATING MODE AIRLOOP M N1 0.135898 2497.40 0.000055
HEAT PUMP HEATING MODE AIRLOOP M N2 0.134507 2477.54 0.000054
HEAT PUMP HEATING MODE AIRLOOP M S1 0.192026 3369.75 0.000074
HEAT PUMP HEATING MODE AIRLOOP M S2 0.193025 3383.58 0.000074
HEAT PUMP HEATING MODE AIRLOOP F6 SW 0.278239 4724.80 0.000103
HEAT PUMP HEATING MODE AIRLOOP F6 NW 0.250466 4310.11 0.000094
HEAT PUMP HEATING MODE AIRLOOP F6 SE 0.254706 4414.82 0.000096
HEAT PUMP HEATING MODE AIRLOOP F6 NE 0.241462 4357.64 0.000095
HEAT PUMP HEATING MODE AIRLOOP F6 N1 0.141680 2628.86 0.000057
HEAT PUMP HEATING MODE AIRLOOP F6 N2 0.141666 2634.80 0.000058
HEAT PUMP HEATING MODE AIRLOOP F6 S1 0.188980 3342.16 0.000073
HEAT PUMP HEATING MODE AIRLOOP F6 S2 0.189977 3355.99 0.000073
HEAT PUMP HEATING MODE AIRLOOP F7 SW 0.277156 4731.90 0.000103
HEAT PUMP HEATING MODE AIRLOOP F7 NW 0.250708 4338.99 0.000095
HEAT PUMP HEATING MODE AIRLOOP F7 SE 0.253855 4424.29 0.000097
HEAT PUMP HEATING MODE AIRLOOP F7 NE 0.250010 4542.98 0.000099
HEAT PUMP HEATING MODE AIRLOOP F7 N1 0.147187 2746.72 0.000060
HEAT PUMP HEATING MODE AIRLOOP F7 N2 0.147172 2752.95 0.000060
HEAT PUMP HEATING MODE AIRLOOP F7 S1 0.188002 3341.47 0.000073
HEAT PUMP HEATING MODE AIRLOOP F7 S2 0.188997 3355.33 0.000073
HEAT PUMP HEATING MODE AIRLOOP F8 SW 0.277195 4752.25 0.000104
HEAT PUMP HEATING MODE AIRLOOP F8 NW 0.259051 4502.70 0.000098
HEAT PUMP HEATING MODE AIRLOOP F8 SE 0.257049 4498.51 0.000098
HEAT PUMP HEATING MODE AIRLOOP F8 NE 0.258295 4717.07 0.000103
HEAT PUMP HEATING MODE AIRLOOP F8 N1 0.152742 2859.93 0.000062
HEAT PUMP HEATING MODE AIRLOOP F8 N2 0.152725 2866.33 0.000063
HEAT PUMP HEATING MODE AIRLOOP F8 S1 0.188114 3354.68 0.000073
HEAT PUMP HEATING MODE AIRLOOP F8 S2 0.189112 3368.59 0.000074
HEAT PUMP HEATING MODE AIRLOOP F9 SW 0.284478 4854.53 0.000106
HEAT PUMP HEATING MODE AIRLOOP F9 NW 0.274327 4762.06 0.000104
HEAT PUMP HEATING MODE AIRLOOP F9 SE 0.272366 4768.51 0.000104
HEAT PUMP HEATING MODE AIRLOOP F9 NE 0.273511 5004.16 0.000109
HEAT PUMP HEATING MODE AIRLOOP F9 N1 0.164906 3067.86 0.000067
HEAT PUMP HEATING MODE AIRLOOP F9 N2 0.164888 3074.38 0.000067
HEAT PUMP HEATING MODE AIRLOOP F9 S1 0.192437 3428.79 0.000075
HEAT PUMP HEATING MODE AIRLOOP F9 S2 0.193499 3441.45 0.000075
HEAT PUMP HEATING MODE AIRLOOP T SW 0.341153 5702.34 0.000125
HEAT PUMP HEATING MODE AIRLOOP T NW 0.315821 5362.38 0.000117
HEAT PUMP HEATING MODE AIRLOOP T SE 0.313486 5332.29 0.000116
HEAT PUMP HEATING MODE AIRLOOP T NE 0.315021 5603.29 0.000122
HEAT PUMP HEATING MODE AIRLOOP T N1 0.207738 3839.49 0.000084
HEAT PUMP HEATING MODE AIRLOOP T N2 0.207719 3845.33 0.000084
HEAT PUMP HEATING MODE AIRLOOP T S1 0.252502 4277.30 0.000093
HEAT PUMP HEATING MODE AIRLOOP T S2 0.253492 4290.87 0.000094


Coil:Heating:Electric

Nominal Capacity [W]
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW 5790.18
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW 5797.70
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE 6934.29
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE 5800.02
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 4447.31
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 4447.35
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 4437.51
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 4443.83
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW 5756.77
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW 5760.11
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE 5771.78
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE 5757.17
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 4049.99
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 4049.93
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 4049.80
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 4050.82
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW 5934.99
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW 5946.68
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE 5930.08
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE 5939.98
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 4101.16
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 4101.01
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 4090.68
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 4090.69
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW 6165.08
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW 6181.89
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE 6155.84
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE 6172.48
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 4230.13
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 4229.93
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 4214.22
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 4214.03
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW 6348.25
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW 6367.52
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE 6336.76
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE 6356.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 4330.10
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 4329.84
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 4311.63
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 4311.38
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW 6570.94
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW 6593.79
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE 6557.70
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE 6580.55
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 4480.77
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 4480.48
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 4458.67
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 4458.38
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW 6750.30
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW 6775.17
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE 6735.63
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE 6760.49
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 4596.67
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 4596.35
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 4572.53
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 4572.21
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW 6924.59
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW 6950.81
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE 6908.67
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE 6934.89
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 4713.56
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 4713.21
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 4688.06
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 4687.71
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW 7248.20
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW 7272.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE 7231.03
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE 7255.12
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 4969.48
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 4969.10
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 4945.66
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 4945.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW 8113.34
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW 8145.63
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE 8096.51
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE 8128.80
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 5870.68
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 5870.29
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 5835.47
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 5835.08


PlantLoop

Maximum Loop Flow Rate [m3/s] Plant Loop Volume [m3]
SHWSYS1 0.000289 0.325214
SINGLE WATER PLANT LOOP 0.006604 7.43


Boiler:HotWater

Design Water Flow Rate [m3/s]
CENTRAL BOILER 0.006604


WaterHeater:Mixed

Use Side Design Flow Rate [m3/s]
SHWSYS1 WATER HEATER 0.000289


EvaporativeFluidCooler:SingleSpeed

Design Water Flow Rate [m3/s] Fan Power at Design Air Flow Rate [W] Design Air Flow Rate [m3/s] U-Factor Times Area Value at Design Air Flow Rate [W/C]
CENTRAL TOWER 0.006604 3187.96 8.83 9391.94


Pump:ConstantSpeed

Rated Flow Rate [m3/s] Rated Power Consumption [W]
SHWSYS1 PUMP 0.000289 36.93
PLANT CIRC PUMP 0.006604 2108.92



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW3 |
G WWALL SWA GWINDOW2 |
G NWALL NWA GWINDOW4 |
G WWALL NWA GWINDOW6 |
G SWALL SEA GWINDOW1 |
G EWALL SEA GWINDOW8 |
G NWALL NEA GWINDOW5 |
G EWALL NEA GWINDOW7 |
G NWALL N1A GWINDOW9 |
G NWALL N2A GWINDOW10 |
G SWALL S1A GWINDOW11 |
G SWALL S2A GWINDOW12 |
G WWALL C GWINDOW13 |
G EWALL C ENTRANCE DOOR |
F2 WWALL SWA F2WINDOW2 |
F2 SWALL SWA F2WINDOW3 |
F2 NWALL NWA F2WINDOW4 |
F2 WWALL NWA F2WINDOW6 |
F2 EWALL SEA F2WINDOW8 |
F2 SWALL SEA F2WINDOW1 |
F2 NWALL NEA F2WINDOW5 |
F2 EWALL NEA F2WINDOW7 |
F2 NWALL N1A F2WINDOW9 |
F2 NWALL N2A F2WINDOW10 |
F2 SWALL S1A F2WINDOW11 |
F2 SWALL S2A F2WINDOW12 |
F2 WWALL C F2WINDOW13 |
F2 EWALL C F2WINDOW14 |
F3 WWALL SWA F3WINDOW2 |
F3 SWALL SWA F3WINDOW3 |
F3 NWALL NWA F3WINDOW4 |
F3 WWALL NWA F3WINDOW6 |
F3 EWALL SEA F3WINDOW8 |
F3 SWALL SEA F3WINDOW1 |
F3 NWALL NEA F3WINDOW5 |
F3 EWALL NEA F3WINDOW7 |
F3 NWALL N1A F3WINDOW9 |
F3 NWALL N2A F3WINDOW10 |
F3 SWALL S1A F3WINDOW11 |
F3 SWALL S2A F3WINDOW12 |
F3 WWALL C F3WINDOW13 |
F3 EWALL C F3WINDOW14 |
F4 WWALL SWA F4WINDOW2 |
F4 SWALL SWA F4WINDOW3 |
F4 NWALL NWA F4WINDOW4 |
F4 WWALL NWA F4WINDOW6 |
F4 EWALL SEA F4WINDOW8 |
F4 SWALL SEA F4WINDOW1 |
F4 NWALL NEA F4WINDOW5 |
F4 EWALL NEA F4WINDOW7 |
F4 NWALL N1A F4WINDOW9 |
F4 NWALL N2A F4WINDOW10 |
F4 SWALL S1A F4WINDOW11 |
F4 SWALL S2A F4WINDOW12 |
F4 WWALL C F4WINDOW13 |
F4 EWALL C F4WINDOW14 |
M WWALL SWA MWINDOW2 |
M SWALL SWA MWINDOW3 |
M NWALL NWA MWINDOW4 |
M WWALL NWA MWINDOW6 |
M EWALL SEA MWINDOW8 |
M SWALL SEA MWINDOW1 |
M NWALL NEA MWINDOW5 |
M EWALL NEA MWINDOW7 |
M NWALL N1A MWINDOW9 |
M NWALL N2A MWINDOW10 |
M SWALL S1A MWINDOW11 |
M SWALL S2A MWINDOW12 |
M WWALL C MWINDOW13 |
M EWALL C MWINDOW14 |
F6 WWALL SWA F6WINDOW2 |
F6 SWALL SWA F6WINDOW3 |
F6 NWALL NWA F6WINDOW4 |
F6 WWALL NWA F6WINDOW6 |
F6 EWALL SEA F6WINDOW8 |
F6 SWALL SEA F6WINDOW1 |
F6 NWALL NEA F6WINDOW5 |
F6 EWALL NEA F6WINDOW7 |
F6 NWALL N1A F6WINDOW9 |
F6 NWALL N2A F6WINDOW10 |
F6 SWALL S1A F6WINDOW11 |
F6 SWALL S2A F6WINDOW12 |
F6 WWALL C F6WINDOW13 |
F6 EWALL C F6WINDOW14 |
F7 WWALL SWA F7WINDOW2 |
F7 SWALL SWA F7WINDOW3 |
F7 NWALL NWA F7WINDOW4 |
F7 WWALL NWA F7WINDOW6 |
F7 EWALL SEA F7WINDOW8 |
F7 SWALL SEA F7WINDOW1 |
F7 NWALL NEA F7WINDOW5 |
F7 EWALL NEA F7WINDOW7 |
F7 NWALL N1A F7WINDOW9 |
F7 NWALL N2A F7WINDOW10 |
F7 SWALL S1A F7WINDOW11 |
F7 SWALL S2A F7WINDOW12 |
F7 WWALL C F7WINDOW13 |
F7 EWALL C F7WINDOW14 |
F8 WWALL SWA F8WINDOW2 |
F8 SWALL SWA F8WINDOW3 |
F8 NWALL NWA F8WINDOW4 |
F8 WWALL NWA F8WINDOW6 |
F8 EWALL SEA F8WINDOW8 |
F8 SWALL SEA F8WINDOW1 |
F8 NWALL NEA F8WINDOW5 |
F8 EWALL NEA F8WINDOW7 |
F8 NWALL N1A F8WINDOW9 |
F8 NWALL N2A F8WINDOW10 |
F8 SWALL S1A F8WINDOW11 |
F8 SWALL S2A F8WINDOW12 |
F8 WWALL C F8WINDOW13 |
F8 EWALL C F8WINDOW14 |
F9 WWALL SWA F9WINDOW2 |
F9 SWALL SWA F9WINDOW3 |
F9 NWALL NWA F9WINDOW4 |
F9 WWALL NWA F9WINDOW6 |
F9 EWALL SEA F9WINDOW8 |
F9 SWALL SEA F9WINDOW1 |
F9 NWALL NEA F9WINDOW5 |
F9 EWALL NEA F9WINDOW7 |
F9 NWALL N1A F9WINDOW9 |
F9 NWALL N2A F9WINDOW10 |
F9 SWALL S1A F9WINDOW11 |
F9 SWALL S2A F9WINDOW12 |
F9 WWALL C F9WINDOW13 |
F9 EWALL C F9WINDOW14 |
T WWALL SWA TWINDOW2 |
T SWALL SWA TWINDOW3 |
T NWALL NWA TWINDOW4 |
T WWALL NWA TWINDOW6 |
T EWALL SEA TWINDOW8 |
T SWALL SEA TWINDOW1 |
T NWALL NEA TWINDOW5 |
T EWALL NEA TWINDOW7 |
T NWALL N1A TWINDOW9 |
T NWALL N2A TWINDOW10 |
T SWALL S1A TWINDOW11 |
T SWALL S2A TWINDOW12 |
T WWALL C TWINDOW13 |
T EWALL C TWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.73 -8.2
March 21.81 -2.6
April 22.11 4.03
May 22.89 12.37
June 23.76 16.19
July 23.97 17.83
August 23.93 17.50
September 23.42 12.89
October 22.07 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.57 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 23.97 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.71 -2.6
April 21.82 4.03
May 22.66 12.37
June 23.71 16.19
July 23.93 17.83
August 23.81 17.50
September 23.01 12.89
October 21.79 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.44 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 23.93 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -13.0
February 21.80 -8.2
March 21.98 -2.6
April 22.40 4.03
May 23.33 12.37
June 24.05 16.19
July 24.21 17.83
August 24.31 17.50
September 23.78 12.89
October 22.37 6.03
November 21.77 -4.5
December 21.71 -11.1
     
Annual Sum or Average 22.79 4.02
Minimum of Months 21.71 -13.0
Maximum of Months 24.31 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.70 -2.6
April 21.79 4.03
May 22.61 12.37
June 23.76 16.19
July 23.93 17.83
August 23.80 17.50
September 22.99 12.89
October 21.79 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.44 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 23.93 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.70 -2.6
April 21.73 4.03
May 22.42 12.37
June 23.64 16.19
July 23.87 17.83
August 23.71 17.50
September 22.96 12.89
October 21.78 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.39 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 23.87 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.70 -2.6
April 21.73 4.03
May 22.41 12.37
June 23.64 16.19
July 23.87 17.83
August 23.70 17.50
September 22.96 12.89
October 21.77 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.39 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 23.87 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.73 -8.2
March 21.80 -2.6
April 22.03 4.03
May 22.72 12.37
June 23.75 16.19
July 23.95 17.83
August 23.91 17.50
September 23.56 12.89
October 22.13 6.03
November 21.71 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.56 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 23.95 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.73 -8.2
March 21.82 -2.6
April 22.06 4.03
May 22.76 12.37
June 23.79 16.19
July 23.97 17.83
August 23.94 17.50
September 23.61 12.89
October 22.15 6.03
November 21.71 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.58 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 23.97 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 11.49 -13.0
February 13.15 -8.2
March 14.90 -2.6
April 17.31 4.03
May 20.48 12.37
June 22.67 16.19
July 23.43 17.83
August 23.14 17.50
September 21.34 12.89
October 17.80 6.03
November 14.18 -4.5
December 12.01 -11.1
     
Annual Sum or Average 17.68 4.02
Minimum of Months 11.49 -13.0
Maximum of Months 23.43 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.77 -8.2
March 21.90 -2.6
April 22.46 4.03
May 23.67 12.37
June 24.11 16.19
July 24.22 17.83
August 24.16 17.50
September 23.77 12.89
October 22.34 6.03
November 21.71 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.80 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.22 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.73 -2.6
April 21.96 4.03
May 23.29 12.37
June 24.04 16.19
July 24.16 17.83
August 24.04 17.50
September 23.25 12.89
October 21.88 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.60 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.16 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.77 -8.2
March 21.92 -2.6
April 22.60 4.03
May 23.77 12.37
June 24.21 16.19
July 24.26 17.83
August 24.21 17.50
September 23.87 12.89
October 22.43 6.03
November 21.71 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.85 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.26 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.71 -2.6
April 21.90 4.03
May 23.18 12.37
June 24.05 16.19
July 24.12 17.83
August 23.99 17.50
September 23.12 12.89
October 21.85 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.57 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.12 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.71 -2.6
April 21.81 4.03
May 23.03 12.37
June 23.99 16.19
July 24.11 17.83
August 23.92 17.50
September 23.13 12.89
October 21.85 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.53 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.11 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.71 -2.6
April 21.81 4.03
May 23.01 12.37
June 23.99 16.19
July 24.10 17.83
August 23.91 17.50
September 23.11 12.89
October 21.85 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.53 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.10 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.80 -8.2
March 21.93 -2.6
April 22.49 4.03
May 23.63 12.37
June 24.13 16.19
July 24.20 17.83
August 24.13 17.50
September 23.91 12.89
October 22.51 6.03
November 21.72 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.83 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.20 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.80 -8.2
March 21.94 -2.6
April 22.51 4.03
May 23.65 12.37
June 24.15 16.19
July 24.21 17.83
August 24.14 17.50
September 23.93 12.89
October 22.52 6.03
November 21.73 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.84 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.21 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.05 -13.0
February 20.69 -8.2
March 21.32 -2.6
April 22.57 4.03
May 24.40 12.37
June 25.47 16.19
July 25.75 17.83
August 25.54 17.50
September 24.58 12.89
October 22.37 6.03
November 20.84 -4.5
December 20.13 -11.1
     
Annual Sum or Average 22.82 4.02
Minimum of Months 20.05 -13.0
Maximum of Months 25.75 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.77 -8.2
March 21.90 -2.6
April 22.51 4.03
May 23.77 12.37
June 24.15 16.19
July 24.23 17.83
August 24.15 17.50
September 23.76 12.89
October 22.35 6.03
November 21.71 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.81 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.23 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.73 -2.6
April 21.98 4.03
May 23.40 12.37
June 24.08 16.19
July 24.18 17.83
August 24.04 17.50
September 23.23 12.89
October 21.89 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.62 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.18 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.76 -8.2
March 21.89 -2.6
April 22.54 4.03
May 23.77 12.37
June 24.19 16.19
July 24.22 17.83
August 24.16 17.50
September 23.75 12.89
October 22.35 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.82 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.22 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.72 -2.6
April 21.92 4.03
May 23.29 12.37
June 24.09 16.19
July 24.14 17.83
August 24.00 17.50
September 23.11 12.89
October 21.86 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.58 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.14 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.71 -2.6
April 21.84 4.03
May 23.19 12.37
June 24.08 16.19
July 24.14 17.83
August 23.94 17.50
September 23.14 12.89
October 21.88 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.57 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.14 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.71 -2.6
April 21.84 4.03
May 23.18 12.37
June 24.08 16.19
July 24.14 17.83
August 23.94 17.50
September 23.12 12.89
October 21.88 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.56 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.14 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.82 -8.2
March 21.95 -2.6
April 22.61 4.03
May 23.82 12.37
June 24.19 16.19
July 24.23 17.83
August 24.13 17.50
September 23.93 12.89
October 22.58 6.03
November 21.72 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.87 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.23 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.82 -8.2
March 21.95 -2.6
April 22.62 4.03
May 23.83 12.37
June 24.20 16.19
July 24.23 17.83
August 24.13 17.50
September 23.94 12.89
October 22.59 6.03
November 21.72 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.88 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.23 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.72 -13.0
February 21.32 -8.2
March 21.86 -2.6
April 23.07 4.03
May 24.90 12.37
June 25.77 16.19
July 25.96 17.83
August 25.74 17.50
September 24.81 12.89
October 22.77 6.03
November 21.37 -4.5
December 20.77 -11.1
     
Annual Sum or Average 23.27 4.02
Minimum of Months 20.72 -13.0
Maximum of Months 25.96 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.77 -8.2
March 21.89 -2.6
April 22.47 4.03
May 23.75 12.37
June 24.14 16.19
July 24.23 17.83
August 24.18 17.50
September 23.74 12.89
October 22.33 6.03
November 21.71 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.81 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.23 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.74 -2.6
April 21.97 4.03
May 23.39 12.37
June 24.07 16.19
July 24.17 17.83
August 24.07 17.50
September 23.20 12.89
October 21.88 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.61 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.17 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.75 -8.2
March 21.88 -2.6
April 22.48 4.03
May 23.73 12.37
June 24.17 16.19
July 24.21 17.83
August 24.17 17.50
September 23.70 12.89
October 22.31 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.80 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.21 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.72 -2.6
April 21.92 4.03
May 23.30 12.37
June 24.09 16.19
July 24.14 17.83
August 24.04 17.50
September 23.09 12.89
October 21.86 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.59 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.14 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.72 -2.6
April 21.85 4.03
May 23.22 12.37
June 24.09 16.19
July 24.15 17.83
August 23.98 17.50
September 23.13 12.89
October 21.88 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.57 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.15 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.72 -2.6
April 21.85 4.03
May 23.21 12.37
June 24.09 16.19
July 24.15 17.83
August 23.98 17.50
September 23.11 12.89
October 21.88 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.57 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.15 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.82 -8.2
March 21.95 -2.6
April 22.60 4.03
May 23.84 12.37
June 24.20 16.19
July 24.23 17.83
August 24.17 17.50
September 23.93 12.89
October 22.58 6.03
November 21.72 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.88 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.23 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.82 -8.2
March 21.95 -2.6
April 22.61 4.03
May 23.84 12.37
June 24.20 16.19
July 24.23 17.83
August 24.17 17.50
September 23.93 12.89
October 22.58 6.03
November 21.72 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.88 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.23 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.85 -13.0
February 21.45 -8.2
March 21.99 -2.6
April 23.20 4.03
May 25.05 12.37
June 25.88 16.19
July 26.06 17.83
August 25.85 17.50
September 24.88 12.89
October 22.88 6.03
November 21.50 -4.5
December 20.90 -11.1
     
Annual Sum or Average 23.38 4.02
Minimum of Months 20.85 -13.0
Maximum of Months 26.06 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.76 -8.2
March 21.88 -2.6
April 22.44 4.03
May 23.71 12.37
June 24.12 16.19
July 24.22 17.83
August 24.17 17.50
September 23.70 12.89
October 22.31 6.03
November 21.71 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.79 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.22 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.74 -2.6
April 21.96 4.03
May 23.36 12.37
June 24.05 16.19
July 24.16 17.83
August 24.06 17.50
September 23.15 12.89
October 21.88 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.60 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.16 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.75 -8.2
March 21.87 -2.6
April 22.44 4.03
May 23.69 12.37
June 24.15 16.19
July 24.20 17.83
August 24.16 17.50
September 23.66 12.89
October 22.29 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.78 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.20 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.72 -2.6
April 21.92 4.03
May 23.29 12.37
June 24.08 16.19
July 24.14 17.83
August 24.03 17.50
September 23.06 12.89
October 21.86 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.58 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.14 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.72 -2.6
April 21.85 4.03
May 23.21 12.37
June 24.08 16.19
July 24.15 17.83
August 23.98 17.50
September 23.10 12.89
October 21.88 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.57 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.15 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.72 -2.6
April 21.85 4.03
May 23.20 12.37
June 24.09 16.19
July 24.14 17.83
August 23.97 17.50
September 23.09 12.89
October 21.88 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.57 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.14 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.81 -8.2
March 21.94 -2.6
April 22.58 4.03
May 23.82 12.37
June 24.19 16.19
July 24.23 17.83
August 24.15 17.50
September 23.90 12.89
October 22.56 6.03
November 21.72 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.86 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.23 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.81 -8.2
March 21.94 -2.6
April 22.58 4.03
May 23.82 12.37
June 24.19 16.19
July 24.23 17.83
August 24.15 17.50
September 23.90 12.89
October 22.56 6.03
November 21.72 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.86 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.23 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.36 -13.0
February 21.98 -8.2
March 22.52 -2.6
April 23.74 4.03
May 25.57 12.37
June 26.41 16.19
July 26.59 17.83
August 26.39 17.50
September 25.39 12.89
October 23.43 6.03
November 22.06 -4.5
December 21.41 -11.1
     
Annual Sum or Average 23.91 4.02
Minimum of Months 21.36 -13.0
Maximum of Months 26.59 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.75 -8.2
March 21.86 -2.6
April 22.37 4.03
May 23.62 12.37
June 24.06 16.19
July 24.17 17.83
August 24.13 17.50
September 23.60 12.89
October 22.24 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.75 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.17 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.73 -2.6
April 21.93 4.03
May 23.27 12.37
June 23.98 16.19
July 24.11 17.83
August 24.01 17.50
September 23.01 12.89
October 21.85 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.56 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.11 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.74 -8.2
March 21.85 -2.6
April 22.36 4.03
May 23.58 12.37
June 24.09 16.19
July 24.15 17.83
August 24.12 17.50
September 23.55 12.89
October 22.22 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.74 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.15 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.72 -2.6
April 21.89 4.03
May 23.21 12.37
June 24.02 16.19
July 24.10 17.83
August 23.99 17.50
September 22.95 12.89
October 21.84 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.55 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.10 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.72 -2.6
April 21.83 4.03
May 23.13 12.37
June 24.01 16.19
July 24.10 17.83
August 23.92 17.50
September 22.97 12.89
October 21.86 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.53 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.10 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.72 -2.6
April 21.83 4.03
May 23.12 12.37
June 24.02 16.19
July 24.10 17.83
August 23.92 17.50
September 22.96 12.89
October 21.86 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.53 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.10 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.80 -8.2
March 21.91 -2.6
April 22.48 4.03
May 23.71 12.37
June 24.14 16.19
July 24.19 17.83
August 24.12 17.50
September 23.80 12.89
October 22.47 6.03
November 21.71 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.82 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.19 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.80 -8.2
March 21.91 -2.6
April 22.48 4.03
May 23.71 12.37
June 24.14 16.19
July 24.19 17.83
August 24.12 17.50
September 23.79 12.89
October 22.47 6.03
November 21.71 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.82 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.19 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.76 -13.0
February 21.36 -8.2
March 21.90 -2.6
April 23.09 4.03
May 24.93 12.37
June 25.79 16.19
July 25.99 17.83
August 25.78 17.50
September 24.72 12.89
October 22.77 6.03
November 21.43 -4.5
December 20.81 -11.1
     
Annual Sum or Average 23.29 4.02
Minimum of Months 20.76 -13.0
Maximum of Months 25.99 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.74 -8.2
March 21.85 -2.6
April 22.32 4.03
May 23.54 12.37
June 24.00 16.19
July 24.14 17.83
August 24.10 17.50
September 23.51 12.89
October 22.20 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.72 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.14 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.73 -2.6
April 21.90 4.03
May 23.21 12.37
June 23.91 16.19
July 24.07 17.83
August 23.97 17.50
September 22.91 12.89
October 21.83 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.53 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.07 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.74 -8.2
March 21.84 -2.6
April 22.30 4.03
May 23.50 12.37
June 24.03 16.19
July 24.11 17.83
August 24.09 17.50
September 23.47 12.89
October 22.18 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.70 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.11 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.72 -2.6
April 21.87 4.03
May 23.16 12.37
June 23.97 16.19
July 24.07 17.83
August 23.95 17.50
September 22.86 12.89
October 21.83 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.52 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.07 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.72 -2.6
April 21.82 4.03
May 23.08 12.37
June 23.95 16.19
July 24.06 17.83
August 23.88 17.50
September 22.88 12.89
October 21.84 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.51 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.06 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.72 -2.6
April 21.81 4.03
May 23.07 12.37
June 23.96 16.19
July 24.06 17.83
August 23.88 17.50
September 22.87 12.89
October 21.84 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.51 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.06 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.79 -8.2
March 21.90 -2.6
April 22.41 4.03
May 23.62 12.37
June 24.09 16.19
July 24.16 17.83
August 24.10 17.50
September 23.72 12.89
October 22.41 6.03
November 21.71 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.78 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.16 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.79 -8.2
March 21.90 -2.6
April 22.41 4.03
May 23.62 12.37
June 24.09 16.19
July 24.16 17.83
August 24.09 17.50
September 23.71 12.89
October 22.41 6.03
November 21.71 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.78 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.16 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.61 -13.0
February 21.21 -8.2
March 21.74 -2.6
April 22.93 4.03
May 24.76 12.37
June 25.64 16.19
July 25.87 17.83
August 25.66 17.50
September 24.53 12.89
October 22.61 6.03
November 21.29 -4.5
December 20.66 -11.1
     
Annual Sum or Average 23.14 4.02
Minimum of Months 20.61 -13.0
Maximum of Months 25.87 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.74 -8.2
March 21.84 -2.6
April 22.28 4.03
May 23.48 12.37
June 23.96 16.19
July 24.11 17.83
August 24.08 17.50
September 23.44 12.89
October 22.16 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.69 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.11 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.73 -2.6
April 21.89 4.03
May 23.17 12.37
June 23.87 16.19
July 24.05 17.83
August 23.94 17.50
September 22.84 12.89
October 21.82 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.51 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.05 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.73 -8.2
March 21.83 -2.6
April 22.26 4.03
May 23.43 12.37
June 23.99 16.19
July 24.08 17.83
August 24.06 17.50
September 23.40 12.89
October 22.15 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.68 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.08 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.72 -2.6
April 21.86 4.03
May 23.12 12.37
June 23.93 16.19
July 24.04 17.83
August 23.92 17.50
September 22.79 12.89
October 21.82 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.50 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.04 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.71 -2.6
April 21.81 4.03
May 23.04 12.37
June 23.90 16.19
July 24.03 17.83
August 23.85 17.50
September 22.80 12.89
October 21.83 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.49 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.03 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.71 -2.6
April 21.81 4.03
May 23.03 12.37
June 23.90 16.19
July 24.03 17.83
August 23.84 17.50
September 22.79 12.89
October 21.83 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.49 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.03 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.78 -8.2
March 21.88 -2.6
April 22.36 4.03
May 23.54 12.37
June 24.04 16.19
July 24.13 17.83
August 24.07 17.50
September 23.64 12.89
October 22.36 6.03
November 21.71 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.75 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.13 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.78 -8.2
March 21.88 -2.6
April 22.36 4.03
May 23.54 12.37
June 24.04 16.19
July 24.12 17.83
August 24.07 17.50
September 23.64 12.89
October 22.36 6.03
November 21.71 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.75 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.12 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.51 -13.0
February 21.12 -8.2
March 21.66 -2.6
April 22.85 4.03
May 24.68 12.37
June 25.57 16.19
July 25.82 17.83
August 25.61 17.50
September 24.42 12.89
October 22.52 6.03
November 21.20 -4.5
December 20.57 -11.1
     
Annual Sum or Average 23.05 4.02
Minimum of Months 20.51 -13.0
Maximum of Months 25.82 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.73 -8.2
March 21.84 -2.6
April 22.25 4.03
May 23.42 12.37
June 23.90 16.19
July 24.06 17.83
August 24.04 17.50
September 23.35 12.89
October 22.13 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.66 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.06 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.73 -2.6
April 21.89 4.03
May 23.14 12.37
June 23.82 16.19
July 24.01 17.83
August 23.91 17.50
September 22.77 12.89
October 21.81 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.50 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.01 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.73 -8.2
March 21.83 -2.6
April 22.24 4.03
May 23.38 12.37
June 23.94 16.19
July 24.05 17.83
August 24.03 17.50
September 23.33 12.89
October 22.12 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.65 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.05 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.72 -2.6
April 21.86 4.03
May 23.10 12.37
June 23.88 16.19
July 24.00 17.83
August 23.89 17.50
September 22.73 12.89
October 21.81 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.49 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.00 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.71 -2.6
April 21.81 4.03
May 23.02 12.37
June 23.84 16.19
July 23.99 17.83
August 23.82 17.50
September 22.73 12.89
October 21.82 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.47 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 23.99 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.71 -2.6
April 21.81 4.03
May 23.02 12.37
June 23.85 16.19
July 23.99 17.83
August 23.81 17.50
September 22.73 12.89
October 21.82 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.47 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 23.99 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.77 -8.2
March 21.87 -2.6
April 22.32 4.03
May 23.47 12.37
June 23.98 16.19
July 24.09 17.83
August 24.04 17.50
September 23.54 12.89
October 22.30 6.03
November 21.71 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.71 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.09 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.77 -8.2
March 21.87 -2.6
April 22.32 4.03
May 23.47 12.37
June 23.98 16.19
July 24.08 17.83
August 24.04 17.50
September 23.54 12.89
October 22.31 6.03
November 21.71 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.71 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 24.08 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.30 -13.0
February 20.94 -8.2
March 21.51 -2.6
April 22.75 4.03
May 24.62 12.37
June 25.53 16.19
July 25.80 17.83
August 25.58 17.50
September 24.31 12.89
October 22.40 6.03
November 21.04 -4.5
December 20.37 -11.1
     
Annual Sum or Average 22.94 4.02
Minimum of Months 20.30 -13.0
Maximum of Months 25.80 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.76 -8.2
March 21.87 -2.6
April 22.30 4.03
May 23.25 12.37
June 23.71 16.19
July 23.90 17.83
August 23.86 17.50
September 23.08 12.89
October 22.11 6.03
November 21.71 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.58 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 23.90 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.75 -2.6
April 21.98 4.03
May 23.04 12.37
June 23.65 16.19
July 23.84 17.83
August 23.72 17.50
September 22.65 12.89
October 21.83 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.44 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 23.84 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.75 -8.2
March 21.86 -2.6
April 22.28 4.03
May 23.23 12.37
June 23.74 16.19
July 23.89 17.83
August 23.83 17.50
September 23.06 12.89
October 22.10 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.58 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 23.89 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.74 -2.6
April 21.93 4.03
May 23.03 12.37
June 23.71 16.19
July 23.85 17.83
August 23.72 17.50
September 22.63 12.89
October 21.83 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.44 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 23.85 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.74 -2.6
April 21.89 4.03
May 22.98 12.37
June 23.69 16.19
July 23.84 17.83
August 23.69 17.50
September 22.62 12.89
October 21.83 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.43 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 23.84 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.70 -8.2
March 21.74 -2.6
April 21.89 4.03
May 22.98 12.37
June 23.70 16.19
July 23.84 17.83
August 23.68 17.50
September 22.62 12.89
October 21.83 6.03
November 21.70 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.43 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 23.84 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.79 -8.2
March 21.90 -2.6
April 22.35 4.03
May 23.32 12.37
June 23.81 16.19
July 23.95 17.83
August 23.91 17.50
September 23.27 12.89
October 22.23 6.03
November 21.72 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.64 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 23.95 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -13.0
February 21.79 -8.2
March 21.90 -2.6
April 22.35 4.03
May 23.32 12.37
June 23.81 16.19
July 23.95 17.83
August 23.91 17.50
September 23.26 12.89
October 22.23 6.03
November 21.72 -4.5
December 21.70 -11.1
     
Annual Sum or Average 22.64 4.02
Minimum of Months 21.70 -13.0
Maximum of Months 23.95 17.83



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 19.95 -13.0
February 20.74 -8.2
March 21.54 -2.6
April 23.04 4.03
May 25.10 12.37
June 26.06 16.19
July 26.36 17.83
August 26.12 17.50
September 24.64 12.89
October 22.57 6.03
November 20.92 -4.5
December 20.05 -11.1
     
Annual Sum or Average 23.10 4.02
Minimum of Months 19.95 -13.0
Maximum of Months 26.36 17.83



Table of Contents

Report: COMPONENTS OF PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2015-09-09 19:00:30

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY {AT MAX/MIN} [W] HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W]
January 0.343948E+12 290808.573 11-JAN-11:00 9104.941 36356.634 20017.053 222001.392 0.000 0.000 2145.842 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
February 0.269574E+12 190142.042 23-FEB-17:00 11327.174 57142.088 20017.053 87150.726 0.000 10364.000 2145.842 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
March 0.268461E+12 146072.512 06-MAR-19:00 14401.373 51749.961 20017.053 45633.257 0.000 10364.000 2145.842 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
April 0.214824E+12 120271.198 10-APR-19:00 14401.373 49889.926 20017.053 21811.700 0.000 10364.000 2145.842 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
May 0.212752E+12 155697.498 18-MAY-17:00 13120.457 57042.023 20017.053 0.000 59359.969 0.000 2145.842 2024.145 0.000 0.000 0.000 0.000 0.000 0.000 0.000
June 0.227305E+12 172990.141 25-JUN-17:15 13120.457 57042.023 20017.053 0.000 75722.153 0.000 2145.842 2954.801 0.000 0.000 0.000 0.000 0.000 0.000 0.000
July 0.243127E+12 173883.274 16-JUL-17:30 13120.457 57042.023 20017.053 0.000 76407.772 0.000 2145.842 3162.117 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 0.230856E+12 167200.330 09-AUG-16:15 11327.174 57142.088 20017.053 0.000 71805.995 0.000 2145.842 2766.981 0.000 0.000 0.000 0.000 0.000 0.000 0.000
September 0.202126E+12 152024.478 17-SEP-16:15 11327.174 57042.023 20017.053 0.000 57202.419 0.000 2145.842 2302.324 0.000 0.000 0.000 0.000 0.000 0.000 0.000
October 0.229802E+12 142096.456 25-OCT-17:15 13120.457 57042.023 20017.053 37419.269 0.000 10364.000 2145.842 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
November 0.274484E+12 170470.699 28-NOV-07:15 9533.891 40866.781 20017.053 86476.222 0.000 10364.000 2145.842 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
December 0.331277E+12 281726.794 19-DEC-02:00 6715.875 19509.987 20017.053 222302.079 0.000 10364.000 2145.842 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
                                     
Annual Sum or Average 0.304854E+13                     0.000 0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.202126E+12 120271.198   6715.875 19509.987 20017.053 0.000 0.000 0.000 2145.842 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.343948E+12 290808.573   14401.373 57142.088 20017.053 222302.079 76407.772 10364.000 2145.842 3162.117 0.000 0.000 0.000 0.000 0.000 0.000 0.000



Table of Contents

Report: COMPONENTS OF PEAK GAS DEMAND

For: Meter

Timestamp: 2015-09-09 19:00:30

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC [Invalid/Undefined] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT {AT MAX/MIN} [W] WATERSYSTEMS:GAS {AT MAX/MIN} [W] WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] HEATING:GAS {AT MAX/MIN} [W]
January 0.660132E+12 415921.913 09-JAN-07:30 0.000 0.000 0.000 415921.913 86889.942 86889.942 329031.970
February 0.473973E+12 396616.237 05-FEB-07:30 0.000 0.000 0.000 396616.237 87085.983 87085.983 309530.254
March 0.397722E+12 351806.177 23-MAR-05:15 0.000 0.000 0.000 351806.177 70672.094 70672.094 281134.083
April 0.196031E+12 180122.232 19-APR-06:00 0.000 0.000 0.000 180122.232 86745.692 86745.692 93376.540
May 0.121744E+12 127880.830 09-MAY-06:30 0.000 0.000 0.000 127880.830 84998.244 84998.244 42882.586
June 0.106894E+12 83378.723 01-JUN-06:00 0.000 0.000 0.000 83378.723 83378.723 83378.723 0.000
July 0.105557E+12 81162.575 02-JUL-06:00 0.000 0.000 0.000 81162.575 81162.575 81162.575 0.000
August 0.103555E+12 115847.079 17-AUG-17:00 0.000 0.000 0.000 115847.079 74481.804 74481.804 41365.275
September 0.103201E+12 118222.106 28-SEP-07:00 0.000 0.000 0.000 118222.106 78477.152 78477.152 39744.954
October 0.206746E+12 243874.140 25-OCT-11:45 0.000 0.000 0.000 243874.140 63612.810 63612.810 180261.331
November 0.424172E+12 393520.219 28-NOV-07:30 0.000 0.000 0.000 393520.219 83615.719 83615.719 309904.500
December 0.624515E+12 411351.482 24-DEC-07:15 0.000 0.000 0.000 411351.482 84766.879 84766.879 326584.602
                     
Annual Sum or Average 0.352424E+13     0.000 0.000 0.000        
Minimum of Months 0.103201E+12 81162.575   0.000 0.000 0.000 81162.575 63612.810 63612.810 0.000
Maximum of Months 0.660132E+12 415921.913   0.000 0.000 0.000 415921.913 87085.983 87085.983 329031.970