Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 19:10
Tabular Output Report in Format: HTML
Building: High-Rise Apartment
Environment: Miami Intl Ap FL USA TMY3 WMO#=722020
Simulation Timestamp: 2015-09-09 19:12:00
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2015-09-09 19:12:00
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 4684.41 | 597.77 | 663.52 |
Net Site Energy | 4684.41 | 597.77 | 663.52 |
Total Source Energy | 13140.25 | 1676.81 | 1861.25 |
Net Source Energy | 13140.25 | 1676.81 | 1861.25 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 7836.48 |
Net Conditioned Building Area | 7059.89 |
Unconditioned Building Area | 776.58 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 2.28 | 2.69 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 1430.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 296.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 163.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1137.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 650.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 79.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 73.72 | 0.00 | 0.00 | 0.00 | 0.00 | 3631.50 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 811.17 | 0.00 | 0.00 | 0.00 | 4778.51 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 3870.55 | 813.86 | 0.00 | 0.00 | 0.00 | 8410.01 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Boiler | 0.00 | 2.69 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Other | 2.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 1430.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 242.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 54.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 163.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 1137.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 650.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 79.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 73.72 | 0.00 | 0.00 | 0.00 | 0.00 | 3631.50 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 811.17 | 0.00 | 0.00 | 0.00 | 0.00 |
sub cat | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4778.51 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 65.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 316.91 | 115.28 | 0.00 | 0.00 | 0.00 | 1.19 |
Other | 161.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 548.24 | 115.28 | 0.00 | 0.00 | 0.00 | 1.19 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 58.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 285.50 | 103.86 | 0.00 | 0.00 | 0.00 | 1.07 |
Other | 145.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 493.91 | 103.86 | 0.00 | 0.00 | 0.00 | 1.07 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 3870.55 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 3870.55 | 100.00 |
Total On-Site and Utility Electric Sources | 3870.55 | 100.00 |
Total Electricity End Uses | 3870.55 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 8410.01 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 8410.01 | 100.00 |
Total Water End Uses | 8410.01 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 1.50 |
Time Setpoint Not Met During Occupied Cooling | 980.25 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 4324.75 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |COMPONENTS OF PEAK ELECTRICAL DEMAND
| Meter |COMPONENTS OF PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2015-09-09 19:12:00
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 19:10 |
RunPeriod | Miami Intl Ap FL USA TMY3 WMO#=722020 |
Weather File | Miami Intl Ap FL USA TMY3 WMO#=722020 |
Latitude [deg] | 25.82 |
Longitude [deg] | -80.3 |
Elevation [m] | 11.00 |
Time Zone | -5.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 3855.02 | 1411.96 | 515.55 | 1411.96 | 515.55 |
Window Opening Area [m2] | 1150.39 | 423.59 | 152.73 | 423.59 | 150.48 |
Window-Wall Ratio [%] | 29.84 | 30.00 | 29.62 | 30.00 | 29.19 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 3752.84 | 1411.96 | 464.46 | 1411.96 | 464.46 |
Window Opening Area [m2] | 1125.85 | 423.59 | 139.34 | 423.59 | 139.34 |
Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 29.5362 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 4.47 | 6.7128 | 0.0000 | |
F2 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F3 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F4 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
M SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 13.4255 | 0.0000 | |
F6 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F7 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F8 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F9 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
T SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 264.3872 | |
Total | 7836.48 | 23884.04 | 3855.02 | 1150.39 | 4.3335 | 39.48 | 8.6291 | |||
Conditioned Total | 7059.89 | 21517.16 | 3752.84 | 1125.85 | 3.9979 | 35.57 | 6.6700 | |||
Unconditioned Total | 776.58 | 2366.87 | 102.18 | 24.54 | 7.3840 | 26.4387 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 19:12:00
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 29-NOV-18:30 | 04-FEB-07:15 | - | - | - | 27-JUL-17:15 |
Heating | 0.00 | 73437.26 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 80892.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 13120.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 10364.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 57042.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 20633.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 2580.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 3797.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 69627.49 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 190419.01 | 143064.75 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | Boiler | 0.00 | 73437.26 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 80892.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 10541.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 2579.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 10364.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 57042.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 20633.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 2580.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 3797.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 69627.49 | 0.00 | 0.00 | 0.00 | 0.00 |
sub cat | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 19:12:00
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 7.21 | 2.92 | 0.00 | 0.00 | 0.00 |
Cooling | 4531.93 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 939.20 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 516.66 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 3601.91 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 2060.74 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 252.35 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 233.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 879.31 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 12258.02 | 882.23 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 1.02 | 0.41 | 0.00 | 0.00 | 0.00 |
Cooling | 641.93 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 133.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 73.18 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 510.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 291.89 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 35.74 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 33.07 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 124.55 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1736.29 | 124.96 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 1.02 | 0.41 | 0.00 | 0.00 | 0.00 |
Cooling | 641.93 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 133.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 73.18 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 510.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 291.89 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 35.74 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 33.07 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 124.55 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1736.29 | 124.96 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2015-09-09 19:12:00
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 8.70 | 0.00 | 8.70 | Wetbulb [C] | 3.80 | 340.00 |
MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 33.20 | 6.70 | 25.30 | Wetbulb [C] | 4.50 | 140.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2015-09-09 19:12:00
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 270.00 | 180.00 | |
F2 WWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
F2 SWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F2 NWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F2 WWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
F2 EWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
F2 SWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F2 NWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F2 EWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
F2 NWALL N1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F2 NWALL N2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F2 SWALL S1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F2 SWALL S2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F2 WWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 270.00 | 90.00 | W |
F2 EWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 90.00 | 90.00 | E |
F3 WWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
F3 SWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F3 NWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F3 WWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
F3 EWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
F3 SWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F3 NWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F3 EWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
F3 NWALL N1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F3 NWALL N2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F3 SWALL S1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F3 SWALL S2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F3 WWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 270.00 | 90.00 | W |
F3 EWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 90.00 | 90.00 | E |
F4 WWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
F4 SWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F4 NWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F4 WWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
F4 EWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
F4 SWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F4 NWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F4 EWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
F4 NWALL N1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F4 NWALL N2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F4 SWALL S1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F4 SWALL S2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F4 WWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 270.00 | 90.00 | W |
F4 EWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 90.00 | 90.00 | E |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
M WWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 90.00 | 90.00 | E |
F6 WWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
F6 SWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F6 NWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F6 WWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
F6 EWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
F6 SWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F6 NWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F6 EWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
F6 NWALL N1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F6 NWALL N2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F6 SWALL S1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F6 SWALL S2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F6 WWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 270.00 | 90.00 | W |
F6 EWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 90.00 | 90.00 | E |
F7 WWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
F7 SWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F7 NWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F7 WWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
F7 EWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
F7 SWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F7 NWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F7 EWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
F7 NWALL N1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F7 NWALL N2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F7 SWALL S1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F7 SWALL S2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F7 WWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 270.00 | 90.00 | W |
F7 EWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 90.00 | 90.00 | E |
F8 WWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
F8 SWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F8 NWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F8 WWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
F8 EWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
F8 SWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F8 NWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F8 EWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
F8 NWALL N1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F8 NWALL N2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F8 SWALL S1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F8 SWALL S2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F8 WWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 270.00 | 90.00 | W |
F8 EWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 90.00 | 90.00 | E |
F9 WWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
F9 SWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F9 NWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F9 WWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
F9 EWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
F9 SWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F9 NWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F9 EWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
F9 NWALL N1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F9 NWALL N2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
F9 SWALL S1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F9 SWALL S2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
F9 WWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 270.00 | 90.00 | W |
F9 EWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 90.00 | 90.00 | E |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.704 | 0.787 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.30 | 0.269 | 0.283 | 77.66 | 0.00 | 0.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW3 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW2 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW4 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW6 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW8 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW5 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW7 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW9 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW10 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW11 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW12 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
GWINDOW13 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 5.778 | 0.306 | 0.155 | No | G WWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_1.22_SHGC_0.25 | 3.36 | 0.00 | 0.00 | 3.36 | 3.36 | 5.778 | 0.306 | 0.155 | No | G EWALL C | 90.00 | 90.00 | E | ||
F2WINDOW2 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F2 WWALL SWA | 270.00 | 90.00 | W | ||
F2WINDOW3 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F2 SWALL SWA | 180.00 | 90.00 | S | ||
F2WINDOW4 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F2 NWALL NWA | 0.00 | 90.00 | N | ||
F2WINDOW6 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F2 WWALL NWA | 270.00 | 90.00 | W | ||
F2WINDOW8 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F2 EWALL SEA | 90.00 | 90.00 | E | ||
F2WINDOW1 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F2 SWALL SEA | 180.00 | 90.00 | S | ||
F2WINDOW5 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F2 NWALL NEA | 0.00 | 90.00 | N | ||
F2WINDOW7 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F2 EWALL NEA | 90.00 | 90.00 | E | ||
F2WINDOW9 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F2 NWALL N1A | 0.00 | 90.00 | N | ||
F2WINDOW10 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F2 NWALL N2A | 0.00 | 90.00 | N | ||
F2WINDOW11 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F2 SWALL S1A | 180.00 | 90.00 | S | ||
F2WINDOW12 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F2 SWALL S2A | 180.00 | 90.00 | S | ||
F2WINDOW13 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 5.778 | 0.306 | 0.155 | No | F2 WWALL C | 270.00 | 90.00 | W | ||
F2WINDOW14 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 5.778 | 0.306 | 0.155 | No | F2 EWALL C | 90.00 | 90.00 | E | ||
F3WINDOW2 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F3 WWALL SWA | 270.00 | 90.00 | W | ||
F3WINDOW3 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F3 SWALL SWA | 180.00 | 90.00 | S | ||
F3WINDOW4 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F3 NWALL NWA | 0.00 | 90.00 | N | ||
F3WINDOW6 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F3 WWALL NWA | 270.00 | 90.00 | W | ||
F3WINDOW8 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F3 EWALL SEA | 90.00 | 90.00 | E | ||
F3WINDOW1 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F3 SWALL SEA | 180.00 | 90.00 | S | ||
F3WINDOW5 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F3 NWALL NEA | 0.00 | 90.00 | N | ||
F3WINDOW7 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F3 EWALL NEA | 90.00 | 90.00 | E | ||
F3WINDOW9 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F3 NWALL N1A | 0.00 | 90.00 | N | ||
F3WINDOW10 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F3 NWALL N2A | 0.00 | 90.00 | N | ||
F3WINDOW11 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F3 SWALL S1A | 180.00 | 90.00 | S | ||
F3WINDOW12 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F3 SWALL S2A | 180.00 | 90.00 | S | ||
F3WINDOW13 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 5.778 | 0.306 | 0.155 | No | F3 WWALL C | 270.00 | 90.00 | W | ||
F3WINDOW14 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 5.778 | 0.306 | 0.155 | No | F3 EWALL C | 90.00 | 90.00 | E | ||
F4WINDOW2 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F4 WWALL SWA | 270.00 | 90.00 | W | ||
F4WINDOW3 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F4 SWALL SWA | 180.00 | 90.00 | S | ||
F4WINDOW4 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F4 NWALL NWA | 0.00 | 90.00 | N | ||
F4WINDOW6 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F4 WWALL NWA | 270.00 | 90.00 | W | ||
F4WINDOW8 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F4 EWALL SEA | 90.00 | 90.00 | E | ||
F4WINDOW1 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F4 SWALL SEA | 180.00 | 90.00 | S | ||
F4WINDOW5 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F4 NWALL NEA | 0.00 | 90.00 | N | ||
F4WINDOW7 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F4 EWALL NEA | 90.00 | 90.00 | E | ||
F4WINDOW9 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F4 NWALL N1A | 0.00 | 90.00 | N | ||
F4WINDOW10 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F4 NWALL N2A | 0.00 | 90.00 | N | ||
F4WINDOW11 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F4 SWALL S1A | 180.00 | 90.00 | S | ||
F4WINDOW12 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F4 SWALL S2A | 180.00 | 90.00 | S | ||
F4WINDOW13 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 5.778 | 0.306 | 0.155 | No | F4 WWALL C | 270.00 | 90.00 | W | ||
F4WINDOW14 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 5.778 | 0.306 | 0.155 | No | F4 EWALL C | 90.00 | 90.00 | E | ||
MWINDOW2 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW3 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW4 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW6 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW8 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW5 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW7 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW9 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW10 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW11 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW12 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW13 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 5.778 | 0.306 | 0.155 | No | M WWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 5.778 | 0.306 | 0.155 | No | M EWALL C | 90.00 | 90.00 | E | ||
F6WINDOW2 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F6 WWALL SWA | 270.00 | 90.00 | W | ||
F6WINDOW3 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F6 SWALL SWA | 180.00 | 90.00 | S | ||
F6WINDOW4 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F6 NWALL NWA | 0.00 | 90.00 | N | ||
F6WINDOW6 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F6 WWALL NWA | 270.00 | 90.00 | W | ||
F6WINDOW8 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F6 EWALL SEA | 90.00 | 90.00 | E | ||
F6WINDOW1 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F6 SWALL SEA | 180.00 | 90.00 | S | ||
F6WINDOW5 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F6 NWALL NEA | 0.00 | 90.00 | N | ||
F6WINDOW7 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F6 EWALL NEA | 90.00 | 90.00 | E | ||
F6WINDOW9 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F6 NWALL N1A | 0.00 | 90.00 | N | ||
F6WINDOW10 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F6 NWALL N2A | 0.00 | 90.00 | N | ||
F6WINDOW11 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F6 SWALL S1A | 180.00 | 90.00 | S | ||
F6WINDOW12 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F6 SWALL S2A | 180.00 | 90.00 | S | ||
F6WINDOW13 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 5.778 | 0.306 | 0.155 | No | F6 WWALL C | 270.00 | 90.00 | W | ||
F6WINDOW14 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 5.778 | 0.306 | 0.155 | No | F6 EWALL C | 90.00 | 90.00 | E | ||
F7WINDOW2 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F7 WWALL SWA | 270.00 | 90.00 | W | ||
F7WINDOW3 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F7 SWALL SWA | 180.00 | 90.00 | S | ||
F7WINDOW4 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F7 NWALL NWA | 0.00 | 90.00 | N | ||
F7WINDOW6 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F7 WWALL NWA | 270.00 | 90.00 | W | ||
F7WINDOW8 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F7 EWALL SEA | 90.00 | 90.00 | E | ||
F7WINDOW1 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F7 SWALL SEA | 180.00 | 90.00 | S | ||
F7WINDOW5 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F7 NWALL NEA | 0.00 | 90.00 | N | ||
F7WINDOW7 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F7 EWALL NEA | 90.00 | 90.00 | E | ||
F7WINDOW9 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F7 NWALL N1A | 0.00 | 90.00 | N | ||
F7WINDOW10 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F7 NWALL N2A | 0.00 | 90.00 | N | ||
F7WINDOW11 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F7 SWALL S1A | 180.00 | 90.00 | S | ||
F7WINDOW12 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F7 SWALL S2A | 180.00 | 90.00 | S | ||
F7WINDOW13 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 5.778 | 0.306 | 0.155 | No | F7 WWALL C | 270.00 | 90.00 | W | ||
F7WINDOW14 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 5.778 | 0.306 | 0.155 | No | F7 EWALL C | 90.00 | 90.00 | E | ||
F8WINDOW2 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F8 WWALL SWA | 270.00 | 90.00 | W | ||
F8WINDOW3 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F8 SWALL SWA | 180.00 | 90.00 | S | ||
F8WINDOW4 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F8 NWALL NWA | 0.00 | 90.00 | N | ||
F8WINDOW6 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F8 WWALL NWA | 270.00 | 90.00 | W | ||
F8WINDOW8 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F8 EWALL SEA | 90.00 | 90.00 | E | ||
F8WINDOW1 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F8 SWALL SEA | 180.00 | 90.00 | S | ||
F8WINDOW5 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F8 NWALL NEA | 0.00 | 90.00 | N | ||
F8WINDOW7 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F8 EWALL NEA | 90.00 | 90.00 | E | ||
F8WINDOW9 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F8 NWALL N1A | 0.00 | 90.00 | N | ||
F8WINDOW10 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F8 NWALL N2A | 0.00 | 90.00 | N | ||
F8WINDOW11 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F8 SWALL S1A | 180.00 | 90.00 | S | ||
F8WINDOW12 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F8 SWALL S2A | 180.00 | 90.00 | S | ||
F8WINDOW13 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 5.778 | 0.306 | 0.155 | No | F8 WWALL C | 270.00 | 90.00 | W | ||
F8WINDOW14 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 5.778 | 0.306 | 0.155 | No | F8 EWALL C | 90.00 | 90.00 | E | ||
F9WINDOW2 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F9 WWALL SWA | 270.00 | 90.00 | W | ||
F9WINDOW3 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F9 SWALL SWA | 180.00 | 90.00 | S | ||
F9WINDOW4 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F9 NWALL NWA | 0.00 | 90.00 | N | ||
F9WINDOW6 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F9 WWALL NWA | 270.00 | 90.00 | W | ||
F9WINDOW8 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F9 EWALL SEA | 90.00 | 90.00 | E | ||
F9WINDOW1 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F9 SWALL SEA | 180.00 | 90.00 | S | ||
F9WINDOW5 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F9 NWALL NEA | 0.00 | 90.00 | N | ||
F9WINDOW7 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | F9 EWALL NEA | 90.00 | 90.00 | E | ||
F9WINDOW9 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F9 NWALL N1A | 0.00 | 90.00 | N | ||
F9WINDOW10 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F9 NWALL N2A | 0.00 | 90.00 | N | ||
F9WINDOW11 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F9 SWALL S1A | 180.00 | 90.00 | S | ||
F9WINDOW12 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | F9 SWALL S2A | 180.00 | 90.00 | S | ||
F9WINDOW13 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 5.778 | 0.306 | 0.155 | No | F9 WWALL C | 270.00 | 90.00 | W | ||
F9WINDOW14 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 5.778 | 0.306 | 0.155 | No | F9 EWALL C | 90.00 | 90.00 | E | ||
TWINDOW2 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW3 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW4 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW6 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW8 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW5 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW7 | WINDOW_U_1.22_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 5.778 | 0.306 | 0.155 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW9 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW10 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW11 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW12 | WINDOW_U_1.22_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 5.778 | 0.306 | 0.155 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW13 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 5.778 | 0.306 | 0.155 | No | T WWALL C | 270.00 | 90.00 | W | ||
TWINDOW14 | WINDOW_U_1.22_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 5.778 | 0.306 | 0.155 | No | T EWALL C | 90.00 | 90.00 | E | ||
Total or Average | 1150.39 | 5.778 | 0.306 | 0.155 | ||||||||||||
North Total or Average | 423.59 | 5.778 | 0.306 | 0.155 | ||||||||||||
Non-North Total or Average | 726.80 | 5.778 | 0.306 | 0.155 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2015-09-09 19:12:00
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
GWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
GWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
GWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
GWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
GWINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
GWINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
GWINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
GWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
MWINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
MWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
MWINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
MWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
MWINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
MWINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
MWINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
MWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
TWINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
TWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
TWINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
TWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
TWINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 |
TWINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
TWINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 |
TWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2015-09-09 19:12:00
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
G SW APARTMENT_LIGHTS_HARDWIRED | G SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G NW APARTMENT_LIGHTS_HARDWIRED | G NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
OFFICE_LIGHTS_HARDWIRED | OFFICE | 14.7681 | 88.25 | 1303.26 | GeneralLights | LTG_OFF_SCH | 62.05 | 168.00 | 61.07 | 0.0000 | Y | 14.94 |
G NE APARTMENT_LIGHTS_HARDWIRED | G NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G N1 APARTMENT_LIGHTS_HARDWIRED | G N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G N2 APARTMENT_LIGHTS_HARDWIRED | G N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G S1 APARTMENT_LIGHTS_HARDWIRED | G S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G S2 APARTMENT_LIGHTS_HARDWIRED | G S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G CORRIDOR_LIGHTS_HARDWIRED | G CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F2 SW APARTMENT_LIGHTS_HARDWIRED | F2 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 NW APARTMENT_LIGHTS_HARDWIRED | F2 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 SE APARTMENT_LIGHTS_HARDWIRED | F2 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 NE APARTMENT_LIGHTS_HARDWIRED | F2 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 N1 APARTMENT_LIGHTS_HARDWIRED | F2 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 N2 APARTMENT_LIGHTS_HARDWIRED | F2 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 S1 APARTMENT_LIGHTS_HARDWIRED | F2 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 S2 APARTMENT_LIGHTS_HARDWIRED | F2 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 CORRIDOR_LIGHTS_HARDWIRED | F2 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F3 SW APARTMENT_LIGHTS_HARDWIRED | F3 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 NW APARTMENT_LIGHTS_HARDWIRED | F3 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 SE APARTMENT_LIGHTS_HARDWIRED | F3 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 NE APARTMENT_LIGHTS_HARDWIRED | F3 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 N1 APARTMENT_LIGHTS_HARDWIRED | F3 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 N2 APARTMENT_LIGHTS_HARDWIRED | F3 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 S1 APARTMENT_LIGHTS_HARDWIRED | F3 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 S2 APARTMENT_LIGHTS_HARDWIRED | F3 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 CORRIDOR_LIGHTS_HARDWIRED | F3 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F4 SW APARTMENT_LIGHTS_HARDWIRED | F4 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 NW APARTMENT_LIGHTS_HARDWIRED | F4 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 SE APARTMENT_LIGHTS_HARDWIRED | F4 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 NE APARTMENT_LIGHTS_HARDWIRED | F4 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 N1 APARTMENT_LIGHTS_HARDWIRED | F4 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 N2 APARTMENT_LIGHTS_HARDWIRED | F4 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 S1 APARTMENT_LIGHTS_HARDWIRED | F4 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 S2 APARTMENT_LIGHTS_HARDWIRED | F4 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 CORRIDOR_LIGHTS_HARDWIRED | F4 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
M SW APARTMENT_LIGHTS_HARDWIRED | M SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M NW APARTMENT_LIGHTS_HARDWIRED | M NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M SE APARTMENT_LIGHTS_HARDWIRED | M SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M NE APARTMENT_LIGHTS_HARDWIRED | M NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M N1 APARTMENT_LIGHTS_HARDWIRED | M N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M N2 APARTMENT_LIGHTS_HARDWIRED | M N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M S1 APARTMENT_LIGHTS_HARDWIRED | M S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M S2 APARTMENT_LIGHTS_HARDWIRED | M S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M CORRIDOR_LIGHTS_HARDWIRED | M CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F6 SW APARTMENT_LIGHTS_HARDWIRED | F6 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 NW APARTMENT_LIGHTS_HARDWIRED | F6 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 SE APARTMENT_LIGHTS_HARDWIRED | F6 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 NE APARTMENT_LIGHTS_HARDWIRED | F6 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 N1 APARTMENT_LIGHTS_HARDWIRED | F6 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 N2 APARTMENT_LIGHTS_HARDWIRED | F6 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 S1 APARTMENT_LIGHTS_HARDWIRED | F6 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 S2 APARTMENT_LIGHTS_HARDWIRED | F6 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 CORRIDOR_LIGHTS_HARDWIRED | F6 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F7 SW APARTMENT_LIGHTS_HARDWIRED | F7 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 NW APARTMENT_LIGHTS_HARDWIRED | F7 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 SE APARTMENT_LIGHTS_HARDWIRED | F7 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 NE APARTMENT_LIGHTS_HARDWIRED | F7 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 N1 APARTMENT_LIGHTS_HARDWIRED | F7 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 N2 APARTMENT_LIGHTS_HARDWIRED | F7 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 S1 APARTMENT_LIGHTS_HARDWIRED | F7 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 S2 APARTMENT_LIGHTS_HARDWIRED | F7 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 CORRIDOR_LIGHTS_HARDWIRED | F7 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F8 SW APARTMENT_LIGHTS_HARDWIRED | F8 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 NW APARTMENT_LIGHTS_HARDWIRED | F8 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 SE APARTMENT_LIGHTS_HARDWIRED | F8 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 NE APARTMENT_LIGHTS_HARDWIRED | F8 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 N1 APARTMENT_LIGHTS_HARDWIRED | F8 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 N2 APARTMENT_LIGHTS_HARDWIRED | F8 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 S1 APARTMENT_LIGHTS_HARDWIRED | F8 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 S2 APARTMENT_LIGHTS_HARDWIRED | F8 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 CORRIDOR_LIGHTS_HARDWIRED | F8 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F9 SW APARTMENT_LIGHTS_HARDWIRED | F9 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 NW APARTMENT_LIGHTS_HARDWIRED | F9 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 SE APARTMENT_LIGHTS_HARDWIRED | F9 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 NE APARTMENT_LIGHTS_HARDWIRED | F9 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 N1 APARTMENT_LIGHTS_HARDWIRED | F9 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 N2 APARTMENT_LIGHTS_HARDWIRED | F9 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 S1 APARTMENT_LIGHTS_HARDWIRED | F9 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 S2 APARTMENT_LIGHTS_HARDWIRED | F9 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 CORRIDOR_LIGHTS_HARDWIRED | F9 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
T SW APARTMENT_LIGHTS_HARDWIRED | T SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T NW APARTMENT_LIGHTS_HARDWIRED | T NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T SE APARTMENT_LIGHTS_HARDWIRED | T SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T NE APARTMENT_LIGHTS_HARDWIRED | T NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T N1 APARTMENT_LIGHTS_HARDWIRED | T N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T N2 APARTMENT_LIGHTS_HARDWIRED | T N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T S1 APARTMENT_LIGHTS_HARDWIRED | T S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T S2 APARTMENT_LIGHTS_HARDWIRED | T S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T CORRIDOR_LIGHTS_HARDWIRED | T CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
G SW APARTMENT_LIGHTS_PLUGIN | G SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G NW APARTMENT_LIGHTS_PLUGIN | G NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
OFFICE_LIGHTS_PLUGIN | OFFICE | 14.7681 | 88.25 | 1303.26 | GeneralLights-plugin | LTG_OFF_SCH | 62.05 | 168.00 | 61.07 | 0.0000 | Y | 14.94 |
G NE APARTMENT_LIGHTS_PLUGIN | G NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G N1 APARTMENT_LIGHTS_PLUGIN | G N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G N2 APARTMENT_LIGHTS_PLUGIN | G N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G S1 APARTMENT_LIGHTS_PLUGIN | G S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G S2 APARTMENT_LIGHTS_PLUGIN | G S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 SW APARTMENT_LIGHTS_PLUGIN | F2 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 NW APARTMENT_LIGHTS_PLUGIN | F2 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 SE APARTMENT_LIGHTS_PLUGIN | F2 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 NE APARTMENT_LIGHTS_PLUGIN | F2 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 N1 APARTMENT_LIGHTS_PLUGIN | F2 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 N2 APARTMENT_LIGHTS_PLUGIN | F2 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 S1 APARTMENT_LIGHTS_PLUGIN | F2 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 S2 APARTMENT_LIGHTS_PLUGIN | F2 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 SW APARTMENT_LIGHTS_PLUGIN | F3 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 NW APARTMENT_LIGHTS_PLUGIN | F3 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 SE APARTMENT_LIGHTS_PLUGIN | F3 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 NE APARTMENT_LIGHTS_PLUGIN | F3 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 N1 APARTMENT_LIGHTS_PLUGIN | F3 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 N2 APARTMENT_LIGHTS_PLUGIN | F3 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 S1 APARTMENT_LIGHTS_PLUGIN | F3 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 S2 APARTMENT_LIGHTS_PLUGIN | F3 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 SW APARTMENT_LIGHTS_PLUGIN | F4 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 NW APARTMENT_LIGHTS_PLUGIN | F4 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 SE APARTMENT_LIGHTS_PLUGIN | F4 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 NE APARTMENT_LIGHTS_PLUGIN | F4 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 N1 APARTMENT_LIGHTS_PLUGIN | F4 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 N2 APARTMENT_LIGHTS_PLUGIN | F4 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 S1 APARTMENT_LIGHTS_PLUGIN | F4 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 S2 APARTMENT_LIGHTS_PLUGIN | F4 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M SW APARTMENT_LIGHTS_PLUGIN | M SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M NW APARTMENT_LIGHTS_PLUGIN | M NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M SE APARTMENT_LIGHTS_PLUGIN | M SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M NE APARTMENT_LIGHTS_PLUGIN | M NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M N1 APARTMENT_LIGHTS_PLUGIN | M N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M N2 APARTMENT_LIGHTS_PLUGIN | M N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M S1 APARTMENT_LIGHTS_PLUGIN | M S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M S2 APARTMENT_LIGHTS_PLUGIN | M S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M CORRIDOR_LIGHTS_PLUGIN | M CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights-plugin | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F6 SW APARTMENT_LIGHTS_PLUGIN | F6 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 NW APARTMENT_LIGHTS_PLUGIN | F6 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 SE APARTMENT_LIGHTS_PLUGIN | F6 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 NE APARTMENT_LIGHTS_PLUGIN | F6 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 N1 APARTMENT_LIGHTS_PLUGIN | F6 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 N2 APARTMENT_LIGHTS_PLUGIN | F6 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 S1 APARTMENT_LIGHTS_PLUGIN | F6 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 S2 APARTMENT_LIGHTS_PLUGIN | F6 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 SW APARTMENT_LIGHTS_PLUGIN | F7 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 NW APARTMENT_LIGHTS_PLUGIN | F7 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 SE APARTMENT_LIGHTS_PLUGIN | F7 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 NE APARTMENT_LIGHTS_PLUGIN | F7 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 N1 APARTMENT_LIGHTS_PLUGIN | F7 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 N2 APARTMENT_LIGHTS_PLUGIN | F7 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 S1 APARTMENT_LIGHTS_PLUGIN | F7 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 S2 APARTMENT_LIGHTS_PLUGIN | F7 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 SW APARTMENT_LIGHTS_PLUGIN | F8 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 NW APARTMENT_LIGHTS_PLUGIN | F8 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 SE APARTMENT_LIGHTS_PLUGIN | F8 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 NE APARTMENT_LIGHTS_PLUGIN | F8 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 N1 APARTMENT_LIGHTS_PLUGIN | F8 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 N2 APARTMENT_LIGHTS_PLUGIN | F8 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 S1 APARTMENT_LIGHTS_PLUGIN | F8 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 S2 APARTMENT_LIGHTS_PLUGIN | F8 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 SW APARTMENT_LIGHTS_PLUGIN | F9 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 NW APARTMENT_LIGHTS_PLUGIN | F9 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 SE APARTMENT_LIGHTS_PLUGIN | F9 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 NE APARTMENT_LIGHTS_PLUGIN | F9 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 N1 APARTMENT_LIGHTS_PLUGIN | F9 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 N2 APARTMENT_LIGHTS_PLUGIN | F9 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 S1 APARTMENT_LIGHTS_PLUGIN | F9 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 S2 APARTMENT_LIGHTS_PLUGIN | F9 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T SW APARTMENT_LIGHTS_PLUGIN | T SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T NW APARTMENT_LIGHTS_PLUGIN | T NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T SE APARTMENT_LIGHTS_PLUGIN | T SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T NE APARTMENT_LIGHTS_PLUGIN | T NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T N1 APARTMENT_LIGHTS_PLUGIN | T N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T N2 APARTMENT_LIGHTS_PLUGIN | T N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T S1 APARTMENT_LIGHTS_PLUGIN | T S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T S2 APARTMENT_LIGHTS_PLUGIN | T S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
Interior Lighting Total | 2.2679 | 14974.03 | 33959.19 | 296.56 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 10364.00 | AstronomicalClock | - | 83.86 | 83.86 | 163.14 | |
Exterior Lighting Total | 10364.00 | 163.14 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2015-09-09 19:12:00
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
CENTRAL BOILER | Boiler:HotWater | 366254.79 | 0.75 | ||
CENTRAL TOWER | EvaporativeFluidCooler:SingleSpeed | 293003.83 |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
HEAT PUMP COOLING MODE AIRLOOP G SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4657.48 | 3073.42 | 1584.07 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4863.02 | 3228.39 | 1634.63 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP OFFICE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6318.01 | 4202.77 | 2115.23 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4067.74 | 2636.58 | 1431.16 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2953.10 | 1845.21 | 1107.89 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2932.89 | 1830.49 | 1102.39 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2652.61 | 1628.90 | 1023.71 | 0.61 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2760.08 | 1697.86 | 1062.22 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5520.21 | 3668.16 | 1852.05 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5743.42 | 3836.61 | 1906.81 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5069.75 | 3332.45 | 1737.30 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4824.96 | 3151.30 | 1673.66 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3525.90 | 2240.36 | 1285.54 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3509.93 | 2228.61 | 1281.31 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3211.16 | 2010.90 | 1200.25 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3250.39 | 2031.94 | 1218.45 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5618.89 | 3708.27 | 1910.61 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5843.03 | 3876.39 | 1966.64 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4884.90 | 3162.20 | 1722.70 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4921.46 | 3192.19 | 1729.27 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3606.30 | 2283.30 | 1323.00 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3590.28 | 2271.58 | 1318.71 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3291.30 | 2054.94 | 1236.35 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3320.73 | 2068.83 | 1251.90 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5701.31 | 3745.16 | 1956.15 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5924.10 | 3911.65 | 2012.45 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4925.51 | 3170.25 | 1755.26 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4991.07 | 3220.72 | 1770.36 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3664.22 | 2313.94 | 1350.28 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3648.15 | 2302.23 | 1345.92 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3351.33 | 2088.06 | 1263.26 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3378.06 | 2100.00 | 1278.06 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5798.04 | 3797.68 | 2000.36 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6020.88 | 3963.78 | 2057.10 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5006.93 | 3213.01 | 1793.91 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5075.18 | 3265.26 | 1809.92 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3741.14 | 2360.73 | 1380.41 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3725.04 | 2349.02 | 1376.02 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3428.91 | 2135.75 | 1293.15 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3454.89 | 2147.24 | 1307.64 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5807.28 | 3787.85 | 2019.43 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6027.95 | 3951.79 | 2076.16 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5004.87 | 3197.12 | 1807.75 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5071.14 | 3247.63 | 1823.51 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3732.06 | 2346.19 | 1385.87 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3715.94 | 2334.52 | 1381.41 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3422.08 | 2123.99 | 1298.09 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3447.63 | 2135.03 | 1312.60 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5839.18 | 3797.27 | 2041.91 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6059.31 | 3960.40 | 2098.91 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5027.06 | 3201.16 | 1825.90 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5092.68 | 3250.98 | 1841.69 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3748.82 | 2351.63 | 1397.19 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3738.74 | 2342.98 | 1395.76 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3439.66 | 2130.75 | 1308.91 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3464.95 | 2141.55 | 1323.40 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5885.54 | 3819.10 | 2066.44 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6105.26 | 3981.58 | 2123.67 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5063.99 | 3217.44 | 1846.55 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5128.81 | 3266.52 | 1862.29 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3788.32 | 2372.90 | 1415.43 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3772.41 | 2361.46 | 1410.95 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3474.14 | 2150.23 | 1323.91 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3497.97 | 2160.00 | 1337.96 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6058.01 | 3935.09 | 2122.92 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6280.73 | 4100.43 | 2180.30 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5167.55 | 3282.99 | 1884.56 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5226.28 | 3327.73 | 1898.54 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3933.58 | 2474.06 | 1459.52 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3917.41 | 2462.38 | 1455.03 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3627.29 | 2254.74 | 1372.54 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3611.35 | 2243.43 | 1367.92 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 7019.59 | 4642.32 | 2377.27 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 7167.59 | 4755.05 | 2412.53 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6064.54 | 3931.73 | 2132.81 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6083.65 | 3947.07 | 2136.59 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4575.97 | 2941.24 | 1634.74 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4541.53 | 2915.86 | 1625.66 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4636.37 | 2980.13 | 1656.24 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4640.93 | 2983.68 | 1657.26 | 0.64 | 0.00 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
None |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
HEAT PUMP HEATING MODE AIRLOOP G SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4657.48 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4863.02 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP OFFICE | Coil:Heating:WaterToAirHeatPump:EquationFit | 6318.01 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4067.74 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2953.10 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2932.89 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2652.61 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2760.08 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5520.21 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5743.42 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5069.75 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4824.96 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3525.90 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3509.93 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3211.16 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3250.39 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5618.89 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5843.03 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4884.90 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4921.46 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3606.30 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3590.28 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3291.30 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3320.73 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5701.31 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5924.10 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4925.51 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4991.07 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3664.22 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3648.15 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3351.33 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3378.06 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5798.04 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 6020.88 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5006.93 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5075.18 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3741.14 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3725.04 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3428.91 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3454.89 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5807.28 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 6027.95 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5004.87 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5071.14 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3732.06 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3715.94 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3422.08 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3447.63 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5839.18 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 6059.31 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5027.06 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5092.68 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3748.82 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3738.74 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3439.66 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3464.95 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5885.54 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 6105.26 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5063.99 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5128.81 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3788.32 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3772.41 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3474.14 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3497.97 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 6058.01 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 6280.73 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5167.55 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5226.28 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3933.58 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3917.41 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3627.29 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3611.35 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 7019.59 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 7167.59 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 6064.54 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 6083.65 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4575.97 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4541.53 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4636.37 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4640.93 | 0.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW | Coil:Heating:Electric | 1633.64 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW | Coil:Heating:Electric | 1628.22 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE | Coil:Heating:Electric | 2118.13 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE | Coil:Heating:Electric | 1630.75 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 | Coil:Heating:Electric | 1092.87 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 | Coil:Heating:Electric | 1092.92 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 | Coil:Heating:Electric | 1094.13 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 | Coil:Heating:Electric | 1099.07 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW | Coil:Heating:Electric | 1791.44 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW | Coil:Heating:Electric | 1790.24 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE | Coil:Heating:Electric | 1810.20 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE | Coil:Heating:Electric | 1790.62 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 | Coil:Heating:Electric | 1115.24 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 | Coil:Heating:Electric | 1115.25 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 | Coil:Heating:Electric | 1117.85 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 | Coil:Heating:Electric | 1119.13 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW | Coil:Heating:Electric | 1826.61 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW | Coil:Heating:Electric | 1828.78 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE | Coil:Heating:Electric | 1827.15 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE | Coil:Heating:Electric | 1827.21 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 | Coil:Heating:Electric | 1122.90 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 | Coil:Heating:Electric | 1122.86 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 | Coil:Heating:Electric | 1119.90 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 | Coil:Heating:Electric | 1120.07 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW | Coil:Heating:Electric | 1870.73 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW | Coil:Heating:Electric | 1875.55 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE | Coil:Heating:Electric | 1867.86 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE | Coil:Heating:Electric | 1872.47 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 | Coil:Heating:Electric | 1145.39 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 | Coil:Heating:Electric | 1145.31 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 | Coil:Heating:Electric | 1139.31 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 | Coil:Heating:Electric | 1139.26 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW | Coil:Heating:Electric | 1890.21 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW | Coil:Heating:Electric | 1896.05 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE | Coil:Heating:Electric | 1885.89 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE | Coil:Heating:Electric | 1891.73 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 | Coil:Heating:Electric | 1148.34 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 | Coil:Heating:Electric | 1148.22 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 | Coil:Heating:Electric | 1141.08 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 | Coil:Heating:Electric | 1140.97 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW | Coil:Heating:Electric | 1964.42 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW | Coil:Heating:Electric | 1972.77 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE | Coil:Heating:Electric | 1959.01 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE | Coil:Heating:Electric | 1967.38 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 | Coil:Heating:Electric | 1205.55 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 | Coil:Heating:Electric | 1205.41 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 | Coil:Heating:Electric | 1195.66 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 | Coil:Heating:Electric | 1195.52 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW | Coil:Heating:Electric | 2013.46 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW | Coil:Heating:Electric | 2023.00 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE | Coil:Heating:Electric | 2007.11 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE | Coil:Heating:Electric | 2016.69 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 | Coil:Heating:Electric | 1240.79 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 | Coil:Heating:Electric | 1240.63 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 | Coil:Heating:Electric | 1229.59 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 | Coil:Heating:Electric | 1229.42 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW | Coil:Heating:Electric | 2060.57 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW | Coil:Heating:Electric | 2070.97 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE | Coil:Heating:Electric | 2053.40 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE | Coil:Heating:Electric | 2063.84 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 | Coil:Heating:Electric | 1275.42 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 | Coil:Heating:Electric | 1275.23 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 | Coil:Heating:Electric | 1263.29 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 | Coil:Heating:Electric | 1263.10 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW | Coil:Heating:Electric | 2172.08 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW | Coil:Heating:Electric | 2181.16 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE | Coil:Heating:Electric | 2164.11 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE | Coil:Heating:Electric | 2173.24 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 | Coil:Heating:Electric | 1367.38 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 | Coil:Heating:Electric | 1367.17 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 | Coil:Heating:Electric | 1356.29 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 | Coil:Heating:Electric | 1356.08 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW | Coil:Heating:Electric | 2412.28 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW | Coil:Heating:Electric | 2425.75 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE | Coil:Heating:Electric | 2404.52 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE | Coil:Heating:Electric | 2418.02 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 | Coil:Heating:Electric | 1654.01 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 | Coil:Heating:Electric | 1653.79 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 | Coil:Heating:Electric | 1637.31 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 | Coil:Heating:Electric | 1637.09 | 1.00 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
AIRLOOP G SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 280.08 | 1160.84 | 1.00 | General |
AIRLOOP G NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.26 | 296.64 | 1160.84 | 1.00 | General |
AIRLOOP OFFICE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 386.58 | 1160.84 | 1.00 | General |
AIRLOOP G NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.20 | 235.41 | 1160.84 | 1.00 | General |
AIRLOOP G N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.13 | 155.21 | 1160.84 | 1.00 | General |
AIRLOOP G N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.13 | 153.66 | 1160.84 | 1.00 | General |
AIRLOOP G S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.11 | 132.46 | 1160.84 | 1.00 | General |
AIRLOOP G S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.12 | 138.20 | 1160.84 | 1.00 | General |
AIRLOOP F2 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.29 | 338.08 | 1160.84 | 1.00 | General |
AIRLOOP F2 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 355.92 | 1160.84 | 1.00 | General |
AIRLOOP F2 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.26 | 303.39 | 1160.84 | 1.00 | General |
AIRLOOP F2 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 284.91 | 1160.84 | 1.00 | General |
AIRLOOP F2 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 194.10 | 1160.84 | 1.00 | General |
AIRLOOP F2 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 192.87 | 1160.84 | 1.00 | General |
AIRLOOP F2 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 169.93 | 1160.84 | 1.00 | General |
AIRLOOP F2 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 170.54 | 1160.84 | 1.00 | General |
AIRLOOP F3 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.29 | 339.26 | 1160.84 | 1.00 | General |
AIRLOOP F3 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 357.17 | 1160.84 | 1.00 | General |
AIRLOOP F3 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 282.52 | 1160.84 | 1.00 | General |
AIRLOOP F3 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 286.32 | 1160.84 | 1.00 | General |
AIRLOOP F3 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 196.89 | 1160.84 | 1.00 | General |
AIRLOOP F3 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 195.66 | 1160.84 | 1.00 | General |
AIRLOOP F3 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 172.88 | 1160.84 | 1.00 | General |
AIRLOOP F3 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 172.75 | 1160.84 | 1.00 | General |
AIRLOOP F4 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.29 | 340.96 | 1160.84 | 1.00 | General |
AIRLOOP F4 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 358.68 | 1160.84 | 1.00 | General |
AIRLOOP F4 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 281.21 | 1160.84 | 1.00 | General |
AIRLOOP F4 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 286.90 | 1160.84 | 1.00 | General |
AIRLOOP F4 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 198.82 | 1160.84 | 1.00 | General |
AIRLOOP F4 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 197.59 | 1160.84 | 1.00 | General |
AIRLOOP F4 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 175.10 | 1160.84 | 1.00 | General |
AIRLOOP F4 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 174.77 | 1160.84 | 1.00 | General |
AIRLOOP M SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 344.71 | 1160.84 | 1.00 | General |
AIRLOOP M NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 362.37 | 1160.84 | 1.00 | General |
AIRLOOP M SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 283.96 | 1160.84 | 1.00 | General |
AIRLOOP M NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 289.82 | 1160.84 | 1.00 | General |
AIRLOOP M N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 202.69 | 1160.84 | 1.00 | General |
AIRLOOP M N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 201.46 | 1160.84 | 1.00 | General |
AIRLOOP M S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 179.08 | 1160.84 | 1.00 | General |
AIRLOOP M S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 178.71 | 1160.84 | 1.00 | General |
AIRLOOP F6 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.29 | 342.15 | 1160.84 | 1.00 | General |
AIRLOOP F6 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 359.57 | 1160.84 | 1.00 | General |
AIRLOOP F6 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 280.80 | 1160.84 | 1.00 | General |
AIRLOOP F6 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 286.47 | 1160.84 | 1.00 | General |
AIRLOOP F6 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 200.25 | 1160.84 | 1.00 | General |
AIRLOOP F6 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 199.02 | 1160.84 | 1.00 | General |
AIRLOOP F6 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 176.97 | 1160.84 | 1.00 | General |
AIRLOOP F6 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 176.56 | 1160.84 | 1.00 | General |
AIRLOOP F7 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.29 | 341.80 | 1160.84 | 1.00 | General |
AIRLOOP F7 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 359.13 | 1160.84 | 1.00 | General |
AIRLOOP F7 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 279.91 | 1160.84 | 1.00 | General |
AIRLOOP F7 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 285.52 | 1160.84 | 1.00 | General |
AIRLOOP F7 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 200.02 | 1160.84 | 1.00 | General |
AIRLOOP F7 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 198.82 | 1160.84 | 1.00 | General |
AIRLOOP F7 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 176.92 | 1160.84 | 1.00 | General |
AIRLOOP F7 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 176.48 | 1160.84 | 1.00 | General |
AIRLOOP F8 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 342.90 | 1160.84 | 1.00 | General |
AIRLOOP F8 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 360.15 | 1160.84 | 1.00 | General |
AIRLOOP F8 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 280.46 | 1160.84 | 1.00 | General |
AIRLOOP F8 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 285.98 | 1160.84 | 1.00 | General |
AIRLOOP F8 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 201.25 | 1160.84 | 1.00 | General |
AIRLOOP F8 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 200.05 | 1160.84 | 1.00 | General |
AIRLOOP F8 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 178.27 | 1160.84 | 1.00 | General |
AIRLOOP F8 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 177.74 | 1160.84 | 1.00 | General |
AIRLOOP F9 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 354.07 | 1160.84 | 1.00 | General |
AIRLOOP F9 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 371.55 | 1160.84 | 1.00 | General |
AIRLOOP F9 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 286.13 | 1160.84 | 1.00 | General |
AIRLOOP F9 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 291.32 | 1160.84 | 1.00 | General |
AIRLOOP F9 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 211.53 | 1160.84 | 1.00 | General |
AIRLOOP F9 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 210.31 | 1160.84 | 1.00 | General |
AIRLOOP F9 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 188.57 | 1160.84 | 1.00 | General |
AIRLOOP F9 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 187.40 | 1160.84 | 1.00 | General |
AIRLOOP T SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.37 | 427.08 | 1160.84 | 1.00 | General |
AIRLOOP T NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.38 | 439.29 | 1160.84 | 1.00 | General |
AIRLOOP T SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 353.01 | 1160.84 | 1.00 | General |
AIRLOOP T NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 354.87 | 1160.84 | 1.00 | General |
AIRLOOP T N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 259.99 | 1160.84 | 1.00 | General |
AIRLOOP T N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 257.33 | 1160.84 | 1.00 | General |
AIRLOOP T S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 262.53 | 1160.84 | 1.00 | General |
AIRLOOP T S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 262.92 | 1160.84 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
SHWSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.0003 | 36.93 | 127739.32 | 0.30 |
PLANT CIRC PUMP | Pump:ConstantSpeed | Intermittent | 224180.02 | 0.0080 | 2544.01 | 319344.75 | 0.90 |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SHWSYS1 WATER HEATER | WaterHeater:Mixed | 2.27 | 175842.64 | 0.80 | 0.00 | 0.00 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:12:00
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 2564.02 | 3076.82 | 0.201 | 0.241 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 32.26 | 0.01715 |
G NW APARTMENT | 2715.71 | 3258.85 | 0.213 | 0.256 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 31.93 | 0.01715 |
OFFICE | 3539.03 | 4246.84 | 0.278 | 0.333 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 31.41 | 0.01715 |
G NE APARTMENT | 2155.06 | 2586.07 | 0.169 | 0.203 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 31.16 | 0.01715 |
G N1 APARTMENT | 1420.98 | 1705.17 | 0.111 | 0.134 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 31.34 | 0.01715 |
G N2 APARTMENT | 1406.78 | 1688.14 | 0.110 | 0.132 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 31.34 | 0.01715 |
G S1 APARTMENT | 1212.72 | 1455.26 | 0.095 | 0.114 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 31.59 | 0.01715 |
G S2 APARTMENT | 1265.24 | 1518.29 | 0.099 | 0.119 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.20 | 0.01715 |
F2 SW APARTMENT | 3094.85 | 3713.82 | 0.243 | 0.291 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 32.09 | 0.01715 |
F2 NW APARTMENT | 3258.29 | 3909.94 | 0.256 | 0.307 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 31.93 | 0.01715 |
F2 SE APARTMENT | 2777.24 | 3332.69 | 0.218 | 0.261 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 31.66 | 0.01715 |
F2 NE APARTMENT | 2608.08 | 3129.70 | 0.205 | 0.245 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 31.16 | 0.01715 |
F2 N1 APARTMENT | 1777.04 | 2132.44 | 0.139 | 0.167 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 31.34 | 0.01715 |
F2 N2 APARTMENT | 1765.73 | 2118.87 | 0.138 | 0.166 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 31.34 | 0.01715 |
F2 S1 APARTMENT | 1555.72 | 1866.86 | 0.122 | 0.146 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 31.59 | 0.01715 |
F2 S2 APARTMENT | 1561.31 | 1873.57 | 0.122 | 0.147 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.20 | 0.01715 |
F3 SW APARTMENT | 3105.48 | 3726.58 | 0.244 | 0.292 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 32.26 | 0.01715 |
F3 NW APARTMENT | 3269.57 | 3923.49 | 0.256 | 0.308 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 31.93 | 0.01715 |
F3 SE APARTMENT | 2586.08 | 3103.29 | 0.203 | 0.243 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 31.66 | 0.01715 |
F3 NE APARTMENT | 2620.86 | 3145.03 | 0.206 | 0.247 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 31.16 | 0.01715 |
F3 N1 APARTMENT | 1802.50 | 2163.00 | 0.141 | 0.170 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 31.34 | 0.01715 |
F3 N2 APARTMENT | 1791.23 | 2149.48 | 0.140 | 0.169 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 31.34 | 0.01715 |
F3 S1 APARTMENT | 1582.69 | 1899.23 | 0.124 | 0.149 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 31.59 | 0.01715 |
F3 S2 APARTMENT | 1581.46 | 1897.76 | 0.124 | 0.149 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.20 | 0.01715 |
F4 SW APARTMENT | 3120.91 | 3745.09 | 0.245 | 0.294 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 32.26 | 0.01715 |
F4 NW APARTMENT | 3283.31 | 3939.97 | 0.257 | 0.309 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 31.93 | 0.01715 |
F4 SE APARTMENT | 2574.02 | 3088.82 | 0.202 | 0.242 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 31.66 | 0.01715 |
F4 NE APARTMENT | 2626.05 | 3151.26 | 0.206 | 0.247 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 31.41 | 0.01715 |
F4 N1 APARTMENT | 1820.12 | 2184.14 | 0.143 | 0.171 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 31.34 | 0.01715 |
F4 N2 APARTMENT | 1808.86 | 2170.63 | 0.142 | 0.170 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 31.34 | 0.01715 |
F4 S1 APARTMENT | 1603.00 | 1923.60 | 0.126 | 0.151 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 31.59 | 0.01715 |
F4 S2 APARTMENT | 1599.93 | 1919.92 | 0.125 | 0.151 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.20 | 0.01715 |
M SW APARTMENT | 3155.14 | 3786.17 | 0.247 | 0.297 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 32.26 | 0.01715 |
M NW APARTMENT | 3317.06 | 3980.47 | 0.260 | 0.312 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 31.93 | 0.01715 |
M SE APARTMENT | 2599.11 | 3118.93 | 0.204 | 0.245 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 31.66 | 0.01715 |
M NE APARTMENT | 2652.80 | 3183.36 | 0.208 | 0.250 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 31.41 | 0.01715 |
M N1 APARTMENT | 1855.52 | 2226.62 | 0.146 | 0.175 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 31.34 | 0.01715 |
M N2 APARTMENT | 1844.27 | 2213.13 | 0.145 | 0.174 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 31.34 | 0.01715 |
M S1 APARTMENT | 1639.43 | 1967.32 | 0.129 | 0.154 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 31.59 | 0.01715 |
M S2 APARTMENT | 1635.94 | 1963.13 | 0.128 | 0.154 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.20 | 0.01715 |
F6 SW APARTMENT | 3131.65 | 3757.98 | 0.246 | 0.295 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 32.26 | 0.01715 |
F6 NW APARTMENT | 3291.38 | 3949.65 | 0.258 | 0.310 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 31.93 | 0.01715 |
F6 SE APARTMENT | 2570.10 | 3084.12 | 0.202 | 0.242 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 31.66 | 0.01715 |
F6 NE APARTMENT | 2622.07 | 3146.49 | 0.206 | 0.247 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 31.41 | 0.01715 |
F6 N1 APARTMENT | 1833.16 | 2199.79 | 0.144 | 0.173 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 31.34 | 0.01715 |
F6 N2 APARTMENT | 1821.97 | 2186.36 | 0.143 | 0.171 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 31.34 | 0.01715 |
F6 S1 APARTMENT | 1620.11 | 1944.14 | 0.127 | 0.152 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 31.59 | 0.01715 |
F6 S2 APARTMENT | 1616.27 | 1939.52 | 0.127 | 0.152 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.20 | 0.01715 |
F7 SW APARTMENT | 3128.44 | 3754.13 | 0.245 | 0.294 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 32.26 | 0.01715 |
F7 NW APARTMENT | 3287.29 | 3944.75 | 0.258 | 0.309 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 31.93 | 0.01715 |
F7 SE APARTMENT | 2561.99 | 3074.39 | 0.201 | 0.241 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 31.66 | 0.01715 |
F7 NE APARTMENT | 2613.26 | 3135.91 | 0.205 | 0.246 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 31.41 | 0.01715 |
F7 N1 APARTMENT | 1831.12 | 2197.34 | 0.144 | 0.172 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 31.34 | 0.01715 |
F7 N2 APARTMENT | 1820.10 | 2184.12 | 0.143 | 0.171 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 31.59 | 0.01715 |
F7 S1 APARTMENT | 1619.58 | 1943.50 | 0.127 | 0.152 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 31.59 | 0.01715 |
F7 S2 APARTMENT | 1615.55 | 1938.66 | 0.127 | 0.152 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.20 | 0.01715 |
F8 SW APARTMENT | 3138.45 | 3766.14 | 0.246 | 0.295 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 32.26 | 0.01715 |
F8 NW APARTMENT | 3296.60 | 3955.92 | 0.259 | 0.310 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 31.93 | 0.01715 |
F8 SE APARTMENT | 2566.91 | 3080.30 | 0.201 | 0.242 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 31.66 | 0.01715 |
F8 NE APARTMENT | 2617.42 | 3140.91 | 0.205 | 0.246 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 31.41 | 0.01715 |
F8 N1 APARTMENT | 1842.29 | 2210.75 | 0.144 | 0.173 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 31.59 | 0.01715 |
F8 N2 APARTMENT | 1831.37 | 2197.65 | 0.144 | 0.172 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 31.59 | 0.01715 |
F8 S1 APARTMENT | 1631.97 | 1958.37 | 0.128 | 0.154 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 31.59 | 0.01715 |
F8 S2 APARTMENT | 1626.98 | 1952.38 | 0.128 | 0.153 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.20 | 0.01715 |
F9 SW APARTMENT | 3240.73 | 3888.88 | 0.254 | 0.305 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 32.09 | 0.01715 |
F9 NW APARTMENT | 3400.88 | 4081.06 | 0.267 | 0.320 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 31.93 | 0.01715 |
F9 SE APARTMENT | 2618.79 | 3142.55 | 0.205 | 0.246 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:15:00 | 31.83 | 0.01715 |
F9 NE APARTMENT | 2666.28 | 3199.53 | 0.209 | 0.251 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 31.41 | 0.01715 |
F9 N1 APARTMENT | 1936.43 | 2323.72 | 0.152 | 0.182 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 31.34 | 0.01715 |
F9 N2 APARTMENT | 1925.24 | 2310.29 | 0.151 | 0.181 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 31.34 | 0.01715 |
F9 S1 APARTMENT | 1726.25 | 2071.50 | 0.135 | 0.162 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 31.59 | 0.01715 |
F9 S2 APARTMENT | 1715.52 | 2058.62 | 0.135 | 0.161 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 31.59 | 0.01715 |
T SW APARTMENT | 3908.72 | 4690.46 | 0.307 | 0.368 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 32.53 | 0.01715 |
T NW APARTMENT | 4020.48 | 4824.57 | 0.315 | 0.378 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 32.26 | 0.01715 |
T SE APARTMENT | 3230.81 | 3876.98 | 0.253 | 0.304 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:30:00 | 31.99 | 0.01715 |
T NE APARTMENT | 3247.78 | 3897.34 | 0.255 | 0.306 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:15:00 | 31.83 | 0.01715 |
T N1 APARTMENT | 2379.97 | 2855.97 | 0.187 | 0.224 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 31.76 | 0.01715 |
T N2 APARTMENT | 2355.63 | 2826.76 | 0.185 | 0.222 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 31.76 | 0.01715 |
T S1 APARTMENT | 2403.08 | 2883.69 | 0.188 | 0.226 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.20 | 0.01715 |
T S2 APARTMENT | 2406.64 | 2887.97 | 0.189 | 0.226 | MIAMI INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.20 | 0.01715 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 1036.68 | 1244.02 | 0.046 | 0.055 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
G NW APARTMENT | 1032.09 | 1238.51 | 0.046 | 0.055 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:15:00 | 8.70 | 0.00699 |
OFFICE | 1284.94 | 1541.93 | 0.057 | 0.069 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 19:00:00 | 8.70 | 0.00699 |
G NE APARTMENT | 1034.23 | 1241.08 | 0.046 | 0.055 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:15:00 | 8.70 | 0.00699 |
G N1 APARTMENT | 579.37 | 695.24 | 0.026 | 0.031 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
G N2 APARTMENT | 579.42 | 695.30 | 0.026 | 0.031 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
G S1 APARTMENT | 580.44 | 696.53 | 0.026 | 0.031 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
G S2 APARTMENT | 584.62 | 701.54 | 0.026 | 0.031 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F2 SW APARTMENT | 1170.12 | 1404.15 | 0.052 | 0.063 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F2 NW APARTMENT | 1169.11 | 1402.93 | 0.052 | 0.063 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F2 SE APARTMENT | 1185.99 | 1423.19 | 0.053 | 0.063 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F2 NE APARTMENT | 1169.44 | 1403.32 | 0.052 | 0.063 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F2 N1 APARTMENT | 598.29 | 717.95 | 0.027 | 0.032 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F2 N2 APARTMENT | 598.30 | 717.96 | 0.027 | 0.032 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F2 S1 APARTMENT | 600.50 | 720.59 | 0.027 | 0.032 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F2 S2 APARTMENT | 601.58 | 721.90 | 0.027 | 0.032 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F3 SW APARTMENT | 1199.87 | 1439.85 | 0.053 | 0.064 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F3 NW APARTMENT | 1201.70 | 1442.04 | 0.054 | 0.064 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F3 SE APARTMENT | 1200.32 | 1440.38 | 0.053 | 0.064 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F3 NE APARTMENT | 1200.37 | 1440.45 | 0.053 | 0.064 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F3 N1 APARTMENT | 604.77 | 725.73 | 0.027 | 0.032 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F3 N2 APARTMENT | 604.74 | 725.69 | 0.027 | 0.032 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F3 S1 APARTMENT | 602.23 | 722.68 | 0.027 | 0.032 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F3 S2 APARTMENT | 602.38 | 722.85 | 0.027 | 0.032 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F4 SW APARTMENT | 1237.18 | 1484.61 | 0.055 | 0.066 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F4 NW APARTMENT | 1241.26 | 1489.51 | 0.055 | 0.066 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F4 SE APARTMENT | 1234.75 | 1481.70 | 0.055 | 0.066 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F4 NE APARTMENT | 1238.65 | 1486.38 | 0.055 | 0.066 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F4 N1 APARTMENT | 623.79 | 748.55 | 0.028 | 0.033 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F4 N2 APARTMENT | 623.72 | 748.47 | 0.028 | 0.033 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F4 S1 APARTMENT | 618.65 | 742.38 | 0.028 | 0.033 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F4 S2 APARTMENT | 618.61 | 742.33 | 0.028 | 0.033 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
M SW APARTMENT | 1253.66 | 1504.39 | 0.056 | 0.067 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
M NW APARTMENT | 1258.59 | 1510.31 | 0.056 | 0.067 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
M SE APARTMENT | 1250.00 | 1500.00 | 0.056 | 0.067 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
M NE APARTMENT | 1254.94 | 1505.93 | 0.056 | 0.067 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
M N1 APARTMENT | 626.28 | 751.54 | 0.028 | 0.033 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
M N2 APARTMENT | 626.19 | 751.42 | 0.028 | 0.033 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
M S1 APARTMENT | 620.14 | 744.17 | 0.028 | 0.033 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
M S2 APARTMENT | 620.05 | 744.06 | 0.028 | 0.033 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F6 SW APARTMENT | 1316.41 | 1579.69 | 0.059 | 0.070 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F6 NW APARTMENT | 1323.47 | 1588.16 | 0.059 | 0.071 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F6 SE APARTMENT | 1311.84 | 1574.20 | 0.058 | 0.070 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F6 NE APARTMENT | 1318.92 | 1582.70 | 0.059 | 0.071 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F6 N1 APARTMENT | 674.67 | 809.60 | 0.030 | 0.036 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F6 N2 APARTMENT | 674.55 | 809.46 | 0.030 | 0.036 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F6 S1 APARTMENT | 666.30 | 799.56 | 0.030 | 0.036 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F6 S2 APARTMENT | 666.18 | 799.42 | 0.030 | 0.036 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F7 SW APARTMENT | 1357.88 | 1629.45 | 0.060 | 0.073 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F7 NW APARTMENT | 1365.95 | 1639.14 | 0.061 | 0.073 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F7 SE APARTMENT | 1352.51 | 1623.02 | 0.060 | 0.072 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F7 NE APARTMENT | 1360.62 | 1632.74 | 0.061 | 0.073 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F7 N1 APARTMENT | 704.47 | 845.36 | 0.031 | 0.038 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F7 N2 APARTMENT | 704.33 | 845.19 | 0.031 | 0.038 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F7 S1 APARTMENT | 694.99 | 833.99 | 0.031 | 0.037 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F7 S2 APARTMENT | 694.85 | 833.82 | 0.031 | 0.037 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F8 SW APARTMENT | 1397.72 | 1677.27 | 0.062 | 0.075 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F8 NW APARTMENT | 1406.51 | 1687.81 | 0.063 | 0.075 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F8 SE APARTMENT | 1391.66 | 1669.99 | 0.062 | 0.074 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F8 NE APARTMENT | 1400.48 | 1680.58 | 0.062 | 0.075 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F8 N1 APARTMENT | 733.75 | 880.50 | 0.033 | 0.039 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F8 N2 APARTMENT | 733.59 | 880.31 | 0.033 | 0.039 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F8 S1 APARTMENT | 723.49 | 868.19 | 0.032 | 0.039 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F8 S2 APARTMENT | 723.33 | 868.00 | 0.032 | 0.039 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F9 SW APARTMENT | 1492.02 | 1790.42 | 0.066 | 0.080 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F9 NW APARTMENT | 1499.70 | 1799.64 | 0.067 | 0.080 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F9 SE APARTMENT | 1485.28 | 1782.34 | 0.066 | 0.079 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F9 NE APARTMENT | 1493.00 | 1791.60 | 0.067 | 0.080 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F9 N1 APARTMENT | 811.52 | 973.82 | 0.036 | 0.043 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F9 N2 APARTMENT | 811.34 | 973.61 | 0.036 | 0.043 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F9 S1 APARTMENT | 802.14 | 962.57 | 0.036 | 0.043 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
F9 S2 APARTMENT | 801.96 | 962.36 | 0.036 | 0.043 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
T SW APARTMENT | 1695.14 | 2034.17 | 0.076 | 0.091 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
T NW APARTMENT | 1706.54 | 2047.84 | 0.076 | 0.091 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
T SE APARTMENT | 1688.59 | 2026.31 | 0.075 | 0.090 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
T NE APARTMENT | 1700.00 | 2040.00 | 0.076 | 0.091 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
T N1 APARTMENT | 1053.91 | 1264.69 | 0.047 | 0.056 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
T N2 APARTMENT | 1053.73 | 1264.47 | 0.047 | 0.056 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
T S1 APARTMENT | 1039.78 | 1247.74 | 0.046 | 0.056 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
T S2 APARTMENT | 1039.60 | 1247.52 | 0.046 | 0.056 | MIAMI INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | 8.70 | 0.00699 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
AIRLOOP G SW | 0.24 | 0.24 | 0.06 | 0.06 |
AIRLOOP G NW | 0.26 | 0.26 | 0.06 | 0.06 |
AIRLOOP OFFICE | 0.33 | 0.33 | 0.07 | 0.07 |
AIRLOOP G NE | 0.20 | 0.20 | 0.06 | 0.06 |
AIRLOOP G N1 | 0.13 | 0.13 | 0.03 | 0.03 |
AIRLOOP G N2 | 0.13 | 0.13 | 0.03 | 0.03 |
AIRLOOP G S1 | 0.11 | 0.11 | 0.03 | 0.03 |
AIRLOOP G S2 | 0.12 | 0.12 | 0.03 | 0.03 |
AIRLOOP F2 SW | 0.29 | 0.29 | 0.06 | 0.06 |
AIRLOOP F2 NW | 0.31 | 0.31 | 0.06 | 0.06 |
AIRLOOP F2 SE | 0.26 | 0.26 | 0.06 | 0.06 |
AIRLOOP F2 NE | 0.25 | 0.25 | 0.06 | 0.06 |
AIRLOOP F2 N1 | 0.17 | 0.17 | 0.03 | 0.03 |
AIRLOOP F2 N2 | 0.17 | 0.17 | 0.03 | 0.03 |
AIRLOOP F2 S1 | 0.15 | 0.15 | 0.03 | 0.03 |
AIRLOOP F2 S2 | 0.15 | 0.15 | 0.03 | 0.03 |
AIRLOOP F3 SW | 0.29 | 0.29 | 0.06 | 0.06 |
AIRLOOP F3 NW | 0.31 | 0.31 | 0.06 | 0.06 |
AIRLOOP F3 SE | 0.24 | 0.24 | 0.06 | 0.06 |
AIRLOOP F3 NE | 0.25 | 0.25 | 0.06 | 0.06 |
AIRLOOP F3 N1 | 0.17 | 0.17 | 0.03 | 0.03 |
AIRLOOP F3 N2 | 0.17 | 0.17 | 0.03 | 0.03 |
AIRLOOP F3 S1 | 0.15 | 0.15 | 0.03 | 0.03 |
AIRLOOP F3 S2 | 0.15 | 0.15 | 0.03 | 0.03 |
AIRLOOP F4 SW | 0.29 | 0.29 | 0.07 | 0.07 |
AIRLOOP F4 NW | 0.31 | 0.31 | 0.07 | 0.07 |
AIRLOOP F4 SE | 0.24 | 0.24 | 0.07 | 0.07 |
AIRLOOP F4 NE | 0.25 | 0.25 | 0.07 | 0.07 |
AIRLOOP F4 N1 | 0.17 | 0.17 | 0.03 | 0.03 |
AIRLOOP F4 N2 | 0.17 | 0.17 | 0.03 | 0.03 |
AIRLOOP F4 S1 | 0.15 | 0.15 | 0.03 | 0.03 |
AIRLOOP F4 S2 | 0.15 | 0.15 | 0.03 | 0.03 |
AIRLOOP M SW | 0.30 | 0.30 | 0.07 | 0.07 |
AIRLOOP M NW | 0.31 | 0.31 | 0.07 | 0.07 |
AIRLOOP M SE | 0.24 | 0.24 | 0.07 | 0.07 |
AIRLOOP M NE | 0.25 | 0.25 | 0.07 | 0.07 |
AIRLOOP M N1 | 0.17 | 0.17 | 0.03 | 0.03 |
AIRLOOP M N2 | 0.17 | 0.17 | 0.03 | 0.03 |
AIRLOOP M S1 | 0.15 | 0.15 | 0.03 | 0.03 |
AIRLOOP M S2 | 0.15 | 0.15 | 0.03 | 0.03 |
AIRLOOP F6 SW | 0.29 | 0.29 | 0.07 | 0.07 |
AIRLOOP F6 NW | 0.31 | 0.31 | 0.07 | 0.07 |
AIRLOOP F6 SE | 0.24 | 0.24 | 0.07 | 0.07 |
AIRLOOP F6 NE | 0.25 | 0.25 | 0.07 | 0.07 |
AIRLOOP F6 N1 | 0.17 | 0.17 | 0.04 | 0.04 |
AIRLOOP F6 N2 | 0.17 | 0.17 | 0.04 | 0.04 |
AIRLOOP F6 S1 | 0.15 | 0.15 | 0.04 | 0.04 |
AIRLOOP F6 S2 | 0.15 | 0.15 | 0.04 | 0.04 |
AIRLOOP F7 SW | 0.29 | 0.29 | 0.07 | 0.07 |
AIRLOOP F7 NW | 0.31 | 0.31 | 0.07 | 0.07 |
AIRLOOP F7 SE | 0.24 | 0.24 | 0.07 | 0.07 |
AIRLOOP F7 NE | 0.25 | 0.25 | 0.07 | 0.07 |
AIRLOOP F7 N1 | 0.17 | 0.17 | 0.04 | 0.04 |
AIRLOOP F7 N2 | 0.17 | 0.17 | 0.04 | 0.04 |
AIRLOOP F7 S1 | 0.15 | 0.15 | 0.04 | 0.04 |
AIRLOOP F7 S2 | 0.15 | 0.15 | 0.04 | 0.04 |
AIRLOOP F8 SW | 0.30 | 0.30 | 0.07 | 0.07 |
AIRLOOP F8 NW | 0.31 | 0.31 | 0.08 | 0.08 |
AIRLOOP F8 SE | 0.24 | 0.24 | 0.07 | 0.07 |
AIRLOOP F8 NE | 0.25 | 0.25 | 0.07 | 0.07 |
AIRLOOP F8 N1 | 0.17 | 0.17 | 0.04 | 0.04 |
AIRLOOP F8 N2 | 0.17 | 0.17 | 0.04 | 0.04 |
AIRLOOP F8 S1 | 0.15 | 0.15 | 0.04 | 0.04 |
AIRLOOP F8 S2 | 0.15 | 0.15 | 0.04 | 0.04 |
AIRLOOP F9 SW | 0.31 | 0.31 | 0.08 | 0.08 |
AIRLOOP F9 NW | 0.32 | 0.32 | 0.08 | 0.08 |
AIRLOOP F9 SE | 0.25 | 0.25 | 0.08 | 0.08 |
AIRLOOP F9 NE | 0.25 | 0.25 | 0.08 | 0.08 |
AIRLOOP F9 N1 | 0.18 | 0.18 | 0.04 | 0.04 |
AIRLOOP F9 N2 | 0.18 | 0.18 | 0.04 | 0.04 |
AIRLOOP F9 S1 | 0.16 | 0.16 | 0.04 | 0.04 |
AIRLOOP F9 S2 | 0.16 | 0.16 | 0.04 | 0.04 |
AIRLOOP T SW | 0.37 | 0.37 | 0.09 | 0.09 |
AIRLOOP T NW | 0.38 | 0.38 | 0.09 | 0.09 |
AIRLOOP T SE | 0.30 | 0.30 | 0.09 | 0.09 |
AIRLOOP T NE | 0.31 | 0.31 | 0.09 | 0.09 |
AIRLOOP T N1 | 0.22 | 0.22 | 0.06 | 0.06 |
AIRLOOP T N2 | 0.22 | 0.22 | 0.06 | 0.06 |
AIRLOOP T S1 | 0.23 | 0.23 | 0.06 | 0.06 |
AIRLOOP T S2 | 0.23 | 0.23 | 0.06 | 0.06 |
Report: System Summary
For: Entire Facility
Timestamp: 2015-09-09 19:12:00
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 7579.50 | 4298.25 | 3416.00 |
G NW APARTMENT | 7257.25 | 4908.00 | 3716.50 |
OFFICE | 2170.50 | 29.75 | 12.00 |
G NE APARTMENT | 7263.25 | 4794.00 | 3568.25 |
G N1 APARTMENT | 7204.50 | 5315.00 | 3991.75 |
G N2 APARTMENT | 7204.50 | 5306.50 | 3982.25 |
G S1 APARTMENT | 7523.25 | 4196.50 | 3295.25 |
G S2 APARTMENT | 7548.75 | 4116.75 | 3236.75 |
F2 SW APARTMENT | 7944.25 | 2338.00 | 1884.00 |
F2 NW APARTMENT | 7537.25 | 3176.50 | 2274.50 |
F2 SE APARTMENT | 8029.50 | 2030.50 | 1647.00 |
F2 NE APARTMENT | 7531.00 | 3078.50 | 2163.75 |
F2 N1 APARTMENT | 7453.00 | 3302.25 | 2338.00 |
F2 N2 APARTMENT | 7452.25 | 3295.00 | 2330.50 |
F2 S1 APARTMENT | 7989.75 | 2115.75 | 1724.25 |
F2 S2 APARTMENT | 7998.00 | 2086.00 | 1703.00 |
F3 SW APARTMENT | 7995.25 | 2387.50 | 1983.50 |
F3 NW APARTMENT | 7602.00 | 3167.75 | 2314.00 |
F3 SE APARTMENT | 8024.00 | 2235.25 | 1829.00 |
F3 NE APARTMENT | 7597.50 | 3062.75 | 2190.25 |
F3 N1 APARTMENT | 7540.50 | 3131.25 | 2252.50 |
F3 N2 APARTMENT | 7539.50 | 3129.50 | 2248.25 |
F3 S1 APARTMENT | 8076.75 | 2085.75 | 1779.00 |
F3 S2 APARTMENT | 8078.00 | 2072.75 | 1768.00 |
F4 SW APARTMENT | 7993.25 | 2450.00 | 2048.25 |
F4 NW APARTMENT | 7611.25 | 3220.25 | 2372.00 |
F4 SE APARTMENT | 8013.25 | 2339.00 | 1914.00 |
F4 NE APARTMENT | 7607.25 | 3116.75 | 2246.25 |
F4 N1 APARTMENT | 7565.25 | 3128.75 | 2272.00 |
F4 N2 APARTMENT | 7565.75 | 3127.00 | 2269.00 |
F4 S1 APARTMENT | 8088.00 | 2116.50 | 1821.50 |
F4 S2 APARTMENT | 8089.50 | 2106.50 | 1810.00 |
M SW APARTMENT | 7988.50 | 2489.75 | 2071.75 |
M NW APARTMENT | 7615.50 | 3231.75 | 2378.75 |
M SE APARTMENT | 8003.50 | 2384.25 | 1942.00 |
M NE APARTMENT | 7607.25 | 3129.50 | 2256.25 |
M N1 APARTMENT | 7576.50 | 3106.25 | 2261.50 |
M N2 APARTMENT | 7575.50 | 3110.25 | 2259.00 |
M S1 APARTMENT | 8084.00 | 2140.50 | 1840.00 |
M S2 APARTMENT | 8082.00 | 2129.75 | 1827.00 |
F6 SW APARTMENT | 7944.50 | 2679.00 | 2199.75 |
F6 NW APARTMENT | 7568.75 | 3420.75 | 2518.00 |
F6 SE APARTMENT | 7959.25 | 2554.50 | 2060.75 |
F6 NE APARTMENT | 7566.75 | 3302.00 | 2389.25 |
F6 N1 APARTMENT | 7529.25 | 3314.75 | 2405.25 |
F6 N2 APARTMENT | 7529.00 | 3312.75 | 2400.75 |
F6 S1 APARTMENT | 8028.75 | 2301.25 | 1941.00 |
F6 S2 APARTMENT | 8025.50 | 2288.25 | 1926.25 |
F7 SW APARTMENT | 7912.00 | 2791.75 | 2276.25 |
F7 NW APARTMENT | 7541.00 | 3520.25 | 2592.75 |
F7 SE APARTMENT | 7924.25 | 2666.00 | 2136.25 |
F7 NE APARTMENT | 7537.50 | 3407.00 | 2470.75 |
F7 N1 APARTMENT | 7500.25 | 3430.50 | 2486.75 |
F7 N2 APARTMENT | 7500.25 | 3424.50 | 2479.50 |
F7 S1 APARTMENT | 7992.00 | 2405.25 | 2010.50 |
F7 S2 APARTMENT | 7990.50 | 2397.00 | 2000.25 |
F8 SW APARTMENT | 7883.50 | 2879.50 | 2329.25 |
F8 NW APARTMENT | 7519.75 | 3600.75 | 2648.00 |
F8 SE APARTMENT | 7897.75 | 2764.00 | 2193.25 |
F8 NE APARTMENT | 7505.50 | 3486.50 | 2527.00 |
F8 N1 APARTMENT | 7479.50 | 3498.25 | 2528.50 |
F8 N2 APARTMENT | 7479.25 | 3495.50 | 2525.25 |
F8 S1 APARTMENT | 7962.00 | 2489.00 | 2062.75 |
F8 S2 APARTMENT | 7963.00 | 2483.50 | 2053.25 |
F9 SW APARTMENT | 7847.50 | 2941.50 | 2344.25 |
F9 NW APARTMENT | 7501.00 | 3629.75 | 2659.25 |
F9 SE APARTMENT | 7859.75 | 2830.25 | 2215.25 |
F9 NE APARTMENT | 7486.50 | 3509.25 | 2528.25 |
F9 N1 APARTMENT | 7464.25 | 3541.00 | 2548.00 |
F9 N2 APARTMENT | 7461.00 | 3537.25 | 2542.75 |
F9 S1 APARTMENT | 7924.00 | 2575.75 | 2101.50 |
F9 S2 APARTMENT | 7920.50 | 2578.75 | 2101.25 |
T SW APARTMENT | 7756.00 | 3638.25 | 2860.25 |
T NW APARTMENT | 7531.75 | 4088.25 | 3069.00 |
T SE APARTMENT | 7771.00 | 3584.50 | 2808.50 |
T NE APARTMENT | 7514.50 | 4045.25 | 3010.00 |
T N1 APARTMENT | 7493.25 | 3929.75 | 2894.25 |
T N2 APARTMENT | 7491.25 | 3930.50 | 2892.50 |
T S1 APARTMENT | 7806.00 | 3274.00 | 2591.00 |
T S2 APARTMENT | 7806.25 | 3277.75 | 2593.75 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 8176.50 | 5638.75 | 4324.75 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 0.00 | 8.25 | 0.00 | 8.25 |
G NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
OFFICE | 0.00 | 2.00 | 0.00 | 0.00 |
G NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
G N1 APARTMENT | 0.75 | 1.75 | 0.75 | 1.75 |
G N2 APARTMENT | 0.25 | 1.75 | 0.25 | 1.75 |
G S1 APARTMENT | 0.00 | 503.50 | 0.00 | 503.50 |
G S2 APARTMENT | 0.25 | 412.75 | 0.25 | 412.75 |
F2 SW APARTMENT | 0.00 | 8.25 | 0.00 | 8.25 |
F2 NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
F2 SE APARTMENT | 0.00 | 43.50 | 0.00 | 43.50 |
F2 NE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
F2 N1 APARTMENT | 0.00 | 1.25 | 0.00 | 1.25 |
F2 N2 APARTMENT | 0.00 | 1.50 | 0.00 | 1.50 |
F2 S1 APARTMENT | 0.00 | 674.25 | 0.00 | 674.25 |
F2 S2 APARTMENT | 0.00 | 629.00 | 0.00 | 629.00 |
F3 SW APARTMENT | 0.00 | 16.75 | 0.00 | 16.75 |
F3 NW APARTMENT | 0.00 | 0.25 | 0.00 | 0.25 |
F3 SE APARTMENT | 0.00 | 149.25 | 0.00 | 149.25 |
F3 NE APARTMENT | 0.00 | 1.50 | 0.00 | 1.50 |
F3 N1 APARTMENT | 0.00 | 10.75 | 0.00 | 10.75 |
F3 N2 APARTMENT | 0.00 | 11.50 | 0.00 | 11.50 |
F3 S1 APARTMENT | 0.00 | 862.50 | 0.00 | 862.50 |
F3 S2 APARTMENT | 0.00 | 822.25 | 0.00 | 822.25 |
F4 SW APARTMENT | 0.00 | 16.25 | 0.00 | 16.25 |
F4 NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
F4 SE APARTMENT | 0.00 | 153.25 | 0.00 | 153.25 |
F4 NE APARTMENT | 0.00 | 2.00 | 0.00 | 2.00 |
F4 N1 APARTMENT | 0.00 | 18.75 | 0.00 | 18.75 |
F4 N2 APARTMENT | 0.00 | 21.00 | 0.00 | 21.00 |
F4 S1 APARTMENT | 0.00 | 839.50 | 0.00 | 839.50 |
F4 S2 APARTMENT | 0.00 | 804.25 | 0.00 | 804.25 |
M SW APARTMENT | 0.00 | 17.25 | 0.00 | 17.25 |
M NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M SE APARTMENT | 0.00 | 145.75 | 0.00 | 145.75 |
M NE APARTMENT | 0.00 | 2.50 | 0.00 | 2.50 |
M N1 APARTMENT | 0.00 | 22.25 | 0.00 | 22.25 |
M N2 APARTMENT | 0.00 | 23.50 | 0.00 | 23.50 |
M S1 APARTMENT | 0.00 | 805.75 | 0.00 | 805.75 |
M S2 APARTMENT | 0.25 | 769.25 | 0.25 | 769.25 |
F6 SW APARTMENT | 0.00 | 17.25 | 0.00 | 17.25 |
F6 NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
F6 SE APARTMENT | 0.00 | 141.00 | 0.00 | 141.00 |
F6 NE APARTMENT | 0.00 | 2.75 | 0.00 | 2.75 |
F6 N1 APARTMENT | 0.00 | 24.00 | 0.00 | 24.00 |
F6 N2 APARTMENT | 0.00 | 24.75 | 0.00 | 24.75 |
F6 S1 APARTMENT | 0.00 | 770.50 | 0.00 | 770.50 |
F6 S2 APARTMENT | 0.00 | 736.00 | 0.00 | 736.00 |
F7 SW APARTMENT | 0.00 | 16.75 | 0.00 | 16.75 |
F7 NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
F7 SE APARTMENT | 0.00 | 133.75 | 0.00 | 133.75 |
F7 NE APARTMENT | 0.00 | 3.00 | 0.00 | 3.00 |
F7 N1 APARTMENT | 0.00 | 25.00 | 0.00 | 25.00 |
F7 N2 APARTMENT | 0.00 | 26.00 | 0.00 | 26.00 |
F7 S1 APARTMENT | 0.25 | 738.50 | 0.25 | 738.50 |
F7 S2 APARTMENT | 0.25 | 706.00 | 0.25 | 706.00 |
F8 SW APARTMENT | 0.00 | 16.00 | 0.00 | 16.00 |
F8 NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
F8 SE APARTMENT | 0.00 | 126.00 | 0.00 | 126.00 |
F8 NE APARTMENT | 0.00 | 3.25 | 0.00 | 3.25 |
F8 N1 APARTMENT | 0.00 | 25.50 | 0.00 | 25.50 |
F8 N2 APARTMENT | 0.00 | 27.00 | 0.00 | 27.00 |
F8 S1 APARTMENT | 0.00 | 700.00 | 0.00 | 700.00 |
F8 S2 APARTMENT | 0.00 | 675.50 | 0.00 | 675.50 |
F9 SW APARTMENT | 0.00 | 12.25 | 0.00 | 12.25 |
F9 NW APARTMENT | 0.00 | 0.75 | 0.00 | 0.75 |
F9 SE APARTMENT | 0.00 | 118.50 | 0.00 | 118.50 |
F9 NE APARTMENT | 0.00 | 3.00 | 0.00 | 3.00 |
F9 N1 APARTMENT | 0.00 | 24.00 | 0.00 | 24.00 |
F9 N2 APARTMENT | 0.00 | 25.00 | 0.00 | 25.00 |
F9 S1 APARTMENT | 0.00 | 597.50 | 0.00 | 597.50 |
F9 S2 APARTMENT | 0.00 | 618.50 | 0.00 | 618.50 |
T SW APARTMENT | 0.00 | 13.25 | 0.00 | 13.25 |
T NW APARTMENT | 0.00 | 3.00 | 0.00 | 3.00 |
T SE APARTMENT | 0.00 | 91.50 | 0.00 | 91.50 |
T NE APARTMENT | 0.00 | 2.25 | 0.00 | 2.25 |
T N1 APARTMENT | 0.00 | 9.75 | 0.00 | 9.75 |
T N2 APARTMENT | 0.00 | 10.25 | 0.00 | 10.25 |
T S1 APARTMENT | 0.00 | 276.25 | 0.00 | 276.25 |
T S2 APARTMENT | 0.00 | 278.00 | 0.00 | 278.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 1.50 | 982.25 | 1.50 | 980.25 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2015-09-09 19:12:00
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.178 | 0.000 | 0.411 |
G NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.178 | 0.000 | 0.397 |
OFFICE | 0.94 | 1.00 | 268.96 | 0.522 | 0.214 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.178 | 0.000 | 0.397 |
G N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.107 | 0.000 | 0.392 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.107 | 0.000 | 0.392 |
G S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.107 | 0.000 | 0.408 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.107 | 0.000 | 0.409 |
F2 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.256 | 0.000 | 0.501 |
F2 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.256 | 0.000 | 0.486 |
F2 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.256 | 0.000 | 0.502 |
F2 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.256 | 0.000 | 0.486 |
F2 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.154 | 0.000 | 0.483 |
F2 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.154 | 0.000 | 0.483 |
F2 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.155 | 0.000 | 0.499 |
F2 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.155 | 0.000 | 0.499 |
F3 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.303 | 0.000 | 0.597 |
F3 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.303 | 0.000 | 0.579 |
F3 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.303 | 0.000 | 0.597 |
F3 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.303 | 0.000 | 0.579 |
F3 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.183 | 0.000 | 0.577 |
F3 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.183 | 0.000 | 0.577 |
F3 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.183 | 0.000 | 0.593 |
F3 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.183 | 0.000 | 0.593 |
F4 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.339 | 0.000 | 0.639 |
F4 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.339 | 0.000 | 0.621 |
F4 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.339 | 0.000 | 0.639 |
F4 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.339 | 0.000 | 0.620 |
F4 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.204 | 0.000 | 0.619 |
F4 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.204 | 0.000 | 0.619 |
F4 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.204 | 0.000 | 0.636 |
F4 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.204 | 0.000 | 0.636 |
M SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.368 | 0.000 | 0.678 |
M NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.368 | 0.000 | 0.658 |
M SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.368 | 0.000 | 0.678 |
M NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.368 | 0.000 | 0.658 |
M N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.222 | 0.000 | 0.656 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.222 | 0.000 | 0.656 |
M S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.222 | 0.000 | 0.675 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.222 | 0.000 | 0.675 |
F6 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.393 | 0.000 | 0.711 |
F6 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.393 | 0.000 | 0.690 |
F6 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.393 | 0.000 | 0.711 |
F6 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.393 | 0.000 | 0.689 |
F6 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.237 | 0.000 | 0.688 |
F6 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.237 | 0.000 | 0.688 |
F6 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.237 | 0.000 | 0.708 |
F6 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.237 | 0.000 | 0.708 |
F7 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.416 | 0.000 | 0.740 |
F7 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.416 | 0.000 | 0.718 |
F7 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.416 | 0.000 | 0.740 |
F7 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.416 | 0.000 | 0.718 |
F7 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.251 | 0.000 | 0.716 |
F7 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.251 | 0.000 | 0.716 |
F7 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.251 | 0.000 | 0.738 |
F7 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.251 | 0.000 | 0.738 |
F8 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.436 | 0.000 | 0.769 |
F8 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.436 | 0.000 | 0.746 |
F8 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.436 | 0.000 | 0.768 |
F8 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.436 | 0.000 | 0.745 |
F8 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.263 | 0.000 | 0.744 |
F8 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.263 | 0.000 | 0.744 |
F8 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.263 | 0.000 | 0.766 |
F8 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.263 | 0.000 | 0.766 |
F9 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.454 | 0.000 | 0.801 |
F9 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.454 | 0.000 | 0.777 |
F9 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.454 | 0.000 | 0.801 |
F9 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.454 | 0.000 | 0.776 |
F9 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.274 | 0.000 | 0.775 |
F9 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.274 | 0.000 | 0.775 |
F9 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.274 | 0.000 | 0.800 |
F9 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.274 | 0.000 | 0.799 |
T SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.471 | 0.000 | 0.823 |
T NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.471 | 0.000 | 0.799 |
T SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.471 | 0.000 | 0.823 |
T NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.471 | 0.000 | 0.799 |
T N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.284 | 0.000 | 0.797 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.284 | 0.000 | 0.797 |
T S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.357 | 0.284 | 0.000 | 0.822 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.357 | 0.284 | 0.000 | 0.823 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.96 | 0.508 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
F2 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F2 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F2 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F2 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F2 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F2 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
F2 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F2 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
F3 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F3 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F3 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F3 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F3 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F3 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
F3 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F3 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
F4 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F4 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F4 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F4 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F4 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F4 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
F4 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F4 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
F6 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F6 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F6 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F6 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F6 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F6 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
F6 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F6 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
F7 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F7 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F7 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F7 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F7 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F7 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
F7 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F7 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
F8 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F8 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F8 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F8 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F8 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F8 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
F8 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F8 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
F9 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F9 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F9 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F9 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F9 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F9 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
F9 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F9 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2015-09-09 19:12:00
Surfaces by ClassTotal | Outdoors | |
Wall | 420 | 140 |
Floor | 90 | 9 |
Roof | 90 | 9 |
Internal Mass | 80 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 140 | 140 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 80 |
Conditioned Zones | 80 |
Unconditioned Zones | 10 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 4156 |
Defaulted Fields | 814 |
Fields with Defaults | 11184 |
Autosized Fields | 1293 |
Autosizable Fields | 1630 |
Autocalculated Fields | 907 |
Autocalculatable Fields | 1710 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2015-09-09 19:12:00
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 3870.55 | 57456.31 | 17-JAN-03:15 | 190419.01 | 29-NOV-18:30 |
Electricity:Building | 1433.88 | 25760.85 | 01-JAN-03:15 | 70162.48 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity | 296.56 | 6715.87 | 01-JAN-00:15 | 14401.37 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 242.55 | 5824.91 | 01-JAN-00:15 | 11484.27 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 39.38 | 663.42 | 01-JAN-00:15 | 2934.49 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 29.88 | 469.18 | 01-JAN-00:15 | 2345.88 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F2 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F2 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F3 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F3 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F4 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F4 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:M SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M CORRIDOR | 32.88 | 1042.61 | 01-JAN-00:15 | 1042.61 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 32.88 | 1042.61 | 01-JAN-00:15 | 1042.61 | 01-JAN-00:15 |
Electricity:Zone:F6 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F6 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F7 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F7 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F8 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F8 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F9 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F9 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:T SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T CORRIDOR | 179.47 | 1701.70 | 01-JAN-00:15 | 10868.20 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 54.01 | 890.97 | 01-JAN-00:15 | 2917.11 | 01-JAN-19:15 |
InteriorEquipment:Electricity | 1137.32 | 19044.98 | 01-JAN-03:15 | 57142.09 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 1137.32 | 19044.98 | 01-JAN-03:15 | 57142.09 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 9.50 | 194.24 | 01-JAN-00:15 | 588.62 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T CORRIDOR | 163.03 | 1180.40 | 01-JAN-00:15 | 10346.90 | 01-JAN-07:15 |
Fans:Electricity | 650.69 | 20633.29 | 08-APR-07:30 | 20633.29 | 01-JAN-00:15 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Electricity:HVAC | 2120.12 | 21294.53 | 17-JAN-03:15 | 113767.42 | 27-JUL-16:15 |
ElectricityProduced:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityProduced:HVAC | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricityProduced | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 3870.55 | 57456.31 | 17-JAN-03:15 | 190419.01 | 29-NOV-18:30 |
ElectricityPurchased:Plant | 3870.55 | 57456.31 | 17-JAN-03:15 | 190419.01 | 29-NOV-18:30 |
Cogeneration:ElectricityPurchased | 3870.55 | 57456.31 | 17-JAN-03:15 | 190419.01 | 29-NOV-18:30 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 3870.55 | 57456.31 | 17-JAN-03:15 | 190419.01 | 29-NOV-18:30 |
ElectricityNet:Plant | 3870.55 | 57456.31 | 17-JAN-03:15 | 190419.01 | 29-NOV-18:30 |
Cogeneration:ElectricityNet | 3870.55 | 57456.31 | 17-JAN-03:15 | 190419.01 | 29-NOV-18:30 |
ExteriorLights:Electricity | 163.14 | 0.00 | 01-JAN-07:15 | 10364.00 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 163.14 | 0.00 | 01-JAN-07:15 | 10364.00 | 01-JAN-00:15 |
General:Fans:Electricity | 650.69 | 20633.29 | 08-APR-07:30 | 20633.29 | 01-JAN-00:15 |
Cooling:Electricity | 1430.98 | 0.00 | 01-JAN-06:15 | 91138.94 | 27-JUL-16:15 |
Heating:Electricity | 2.28 | 0.00 | 01-JAN-00:15 | 23370.41 | 04-FEB-06:00 |
Electricity:Plant | 153.40 | 36.93 | 01-JAN-06:15 | 6426.61 | 08-JUN-16:15 |
HeatRejection:Electricity | 73.72 | 0.00 | 01-JAN-06:15 | 3845.68 | 08-JUN-16:15 |
Boiler Parasitic:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Pumps:Electricity | 79.68 | 36.93 | 01-JAN-06:15 | 2580.93 | 01-JAN-00:15 |
WIRED_LTG_ELECTRICITY | 0.44 | 0.00 | 01-JAN-00:15 | 21.60 | 01-JAN-19:30 |
WIRED_INT_EQUIP | 979.40 | 1018.50 | 01-JAN-00:15 | 10185.00 | 01-JAN-07:15 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 813.86 | 2357.00 | 01-JAN-00:15 | 143064.75 | 04-FEB-07:15 |
Gas:Plant | 813.86 | 2357.00 | 01-JAN-00:15 | 143064.75 | 04-FEB-07:15 |
WaterSystems:Gas | 811.17 | 2357.00 | 01-JAN-00:15 | 70351.58 | 18-JAN-08:00 |
Water Heater:WaterSystems:Gas | 811.17 | 2357.00 | 01-JAN-00:15 | 70351.58 | 18-JAN-08:00 |
Heating:Gas | 2.69 | 0.00 | 01-JAN-00:15 | 81475.49 | 04-FEB-06:00 |
Boiler:Heating:Gas | 2.69 | 0.00 | 01-JAN-00:15 | 81475.49 | 04-FEB-06:00 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
PlantLoopCoolingDemand:Facility | 6512.96 | 0.00 | 01-JAN-06:15 | 454062.42 | 29-NOV-11:45 |
PlantLoopCoolingDemand:HVAC | 6512.96 | 0.00 | 01-JAN-06:15 | 454062.42 | 29-NOV-11:45 |
CoolingCoils:PlantLoopCoolingDemand | 6512.96 | 0.00 | 01-JAN-06:15 | 454062.42 | 29-NOV-11:45 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 8410.01 | 0.00 | 09-JAN-02:15 | 0.00 | 27-JUL-17:15 |
Water:Plant | 8410.01 | 0.00 | 09-JAN-02:15 | 0.00 | 27-JUL-17:15 |
WaterSystems:Water | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:Water | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
MainsWater:Facility | 8410.01 | 0.00 | 09-JAN-02:15 | 0.00 | 27-JUL-17:15 |
MainsWater:Plant | 8410.01 | 0.00 | 09-JAN-02:15 | 0.00 | 27-JUL-17:15 |
WaterSystems:MainsWater | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:MainsWater | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
sub cat:WaterSystems:Water | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
sub cat:WaterSystems:MainsWater | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
HeatRejection:Water | 3631.50 | 0.00 | 01-JAN-06:15 | 0.00 | 27-JUL-16:30 |
HeatRejection:MainsWater | 3631.50 | 0.00 | 01-JAN-06:15 | 0.00 | 27-JUL-16:30 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 631.85 | 332.83 | 23-JUL-01:15 | 101226.98 | 04-FEB-06:15 |
PlantLoopHeatingDemand:Plant | 626.05 | 332.83 | 23-JUL-01:15 | 41392.23 | 19-JAN-07:45 |
WaterSystems:PlantLoopHeatingDemand | 626.05 | 332.83 | 23-JUL-01:15 | 41392.23 | 19-JAN-07:45 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 8344.44 | 5920.01 | 28-DEC-04:00 | 569828.07 | 27-JUL-16:15 |
EnergyTransfer:Building | 2540.13 | 4132.33 | 21-DEC-22:15 | 209377.86 | 29-JUL-16:30 |
EnergyTransfer:Zone:G SW APARTMENT | 25.08 | 0.01 | 11-JAN-05:30 | 3006.31 | 30-SEP-14:30 |
Heating:EnergyTransfer | 35.62 | 0.00 | 01-JAN-09:45 | 69502.74 | 05-FEB-09:30 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 0.58 | 0.00 | 01-JAN-00:15 | 796.06 | 04-FEB-05:00 |
Cooling:EnergyTransfer | 2504.51 | 0.00 | 01-JAN-06:15 | 209377.86 | 29-JUL-16:30 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 24.51 | 0.00 | 01-JAN-01:15 | 3006.31 | 30-SEP-14:30 |
EnergyTransfer:Zone:G NW APARTMENT | 20.85 | 0.04 | 05-JAN-23:00 | 2929.87 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 1.05 | 0.00 | 01-JAN-09:45 | 1109.32 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 19.80 | 0.00 | 01-JAN-00:15 | 2929.87 | 29-JUL-16:30 |
EnergyTransfer:Zone:OFFICE | 35.89 | 0.02 | 23-FEB-06:00 | 4140.60 | 29-SEP-12:30 |
Heating:EnergyTransfer:Zone:OFFICE | 0.22 | 0.00 | 01-JAN-00:15 | 782.32 | 04-FEB-07:00 |
Cooling:EnergyTransfer:Zone:OFFICE | 35.67 | 0.00 | 01-JAN-02:15 | 4140.60 | 29-SEP-12:30 |
EnergyTransfer:Zone:G NE APARTMENT | 20.80 | 0.06 | 10-JAN-00:30 | 2298.17 | 25-JUL-10:15 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 0.76 | 0.00 | 01-JAN-00:15 | 945.22 | 04-FEB-05:00 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 20.04 | 0.00 | 01-JAN-00:30 | 2298.17 | 25-JUL-10:15 |
EnergyTransfer:Zone:G N1 APARTMENT | 14.31 | 0.01 | 02-NOV-00:45 | 1608.51 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 0.41 | 0.00 | 01-JAN-00:15 | 948.26 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 13.90 | 0.00 | 01-JAN-00:30 | 1608.51 | 29-JUL-16:30 |
EnergyTransfer:Zone:G N2 APARTMENT | 14.32 | 0.00 | 27-FEB-23:45 | 1595.16 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 0.40 | 0.00 | 01-JAN-00:15 | 936.78 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 13.92 | 0.00 | 01-JAN-00:30 | 1595.16 | 29-JUL-16:30 |
EnergyTransfer:Zone:G S1 APARTMENT | 18.67 | 0.00 | 11-MAR-20:30 | 1903.65 | 27-FEB-13:15 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.07 | 0.00 | 01-JAN-00:15 | 326.83 | 19-DEC-09:30 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 18.60 | 0.00 | 01-JAN-06:15 | 1903.65 | 27-FEB-13:15 |
EnergyTransfer:Zone:G S2 APARTMENT | 19.21 | 0.03 | 06-DEC-04:15 | 1951.84 | 27-FEB-13:15 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.07 | 0.00 | 01-JAN-00:15 | 308.64 | 12-NOV-09:45 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 19.14 | 0.00 | 01-JAN-06:15 | 1951.84 | 27-FEB-13:15 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F2 SW APARTMENT | 38.24 | 0.07 | 20-MAR-10:30 | 3932.72 | 07-NOV-15:15 |
Heating:EnergyTransfer:Zone:F2 SW APARTMENT | 0.34 | 0.00 | 01-JAN-00:15 | 714.87 | 04-FEB-06:00 |
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT | 37.89 | 0.00 | 01-JAN-06:15 | 3932.72 | 07-NOV-15:15 |
EnergyTransfer:Zone:F2 NW APARTMENT | 31.47 | 0.04 | 15-JAN-01:45 | 3472.95 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F2 NW APARTMENT | 0.77 | 0.00 | 01-JAN-00:15 | 1240.34 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT | 30.70 | 0.00 | 01-JAN-06:15 | 3472.95 | 29-JUL-16:30 |
EnergyTransfer:Zone:F2 SE APARTMENT | 40.71 | 0.06 | 23-FEB-07:00 | 3518.27 | 07-NOV-14:30 |
Heating:EnergyTransfer:Zone:F2 SE APARTMENT | 0.23 | 0.00 | 01-JAN-00:15 | 660.48 | 04-FEB-06:00 |
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT | 40.48 | 0.00 | 01-JAN-06:15 | 3518.27 | 07-NOV-14:30 |
EnergyTransfer:Zone:F2 NE APARTMENT | 31.53 | 0.07 | 01-MAR-03:00 | 2818.65 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F2 NE APARTMENT | 0.51 | 0.00 | 01-JAN-00:15 | 997.93 | 04-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT | 31.02 | 0.00 | 01-JAN-06:15 | 2818.65 | 29-JUL-16:30 |
EnergyTransfer:Zone:F2 N1 APARTMENT | 23.37 | 0.01 | 18-DEC-01:45 | 2020.12 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT | 0.23 | 0.00 | 01-JAN-00:15 | 973.33 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT | 23.14 | 0.00 | 01-JAN-06:15 | 2020.12 | 29-JUL-16:30 |
EnergyTransfer:Zone:F2 N2 APARTMENT | 23.38 | 0.03 | 12-FEB-07:00 | 2009.61 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT | 0.22 | 0.00 | 01-JAN-00:15 | 966.24 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT | 23.16 | 0.00 | 01-JAN-06:15 | 2009.61 | 29-JUL-16:30 |
EnergyTransfer:Zone:F2 S1 APARTMENT | 30.06 | 0.01 | 27-DEC-19:00 | 2539.70 | 22-FEB-14:00 |
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT | 0.03 | 0.00 | 01-JAN-00:15 | 98.24 | 18-MAR-05:15 |
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT | 30.03 | 0.00 | 01-JAN-06:15 | 2539.70 | 22-FEB-14:00 |
EnergyTransfer:Zone:F2 S2 APARTMENT | 30.26 | 0.04 | 26-DEC-10:30 | 2568.32 | 22-FEB-14:00 |
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT | 0.03 | 0.00 | 01-JAN-00:15 | 100.26 | 18-MAR-05:15 |
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT | 30.23 | 0.00 | 01-JAN-06:15 | 2568.32 | 22-FEB-14:00 |
EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F3 SW APARTMENT | 39.89 | 0.06 | 10-APR-05:15 | 3988.53 | 07-NOV-15:15 |
Heating:EnergyTransfer:Zone:F3 SW APARTMENT | 0.33 | 0.00 | 01-JAN-00:15 | 757.33 | 04-FEB-06:00 |
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT | 39.56 | 0.00 | 01-JAN-06:15 | 3988.53 | 07-NOV-15:15 |
EnergyTransfer:Zone:F3 NW APARTMENT | 33.28 | 0.08 | 21-DEC-02:00 | 3487.07 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F3 NW APARTMENT | 0.74 | 0.00 | 01-JAN-00:15 | 1410.71 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT | 32.54 | 0.00 | 01-JAN-06:15 | 3487.07 | 29-JUL-16:30 |
EnergyTransfer:Zone:F3 SE APARTMENT | 40.30 | 0.01 | 15-MAR-00:15 | 3364.39 | 07-NOV-15:00 |
Heating:EnergyTransfer:Zone:F3 SE APARTMENT | 0.21 | 0.00 | 01-JAN-00:15 | 792.57 | 04-FEB-06:00 |
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT | 40.09 | 0.00 | 01-JAN-06:15 | 3364.39 | 07-NOV-15:00 |
EnergyTransfer:Zone:F3 NE APARTMENT | 33.33 | 0.02 | 26-FEB-06:00 | 2848.50 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F3 NE APARTMENT | 0.49 | 0.00 | 01-JAN-00:15 | 1071.59 | 04-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT | 32.84 | 0.00 | 01-JAN-06:15 | 2848.50 | 29-JUL-16:30 |
EnergyTransfer:Zone:F3 N1 APARTMENT | 25.40 | 0.01 | 19-DEC-09:45 | 2061.68 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT | 0.21 | 0.00 | 01-JAN-00:15 | 1118.63 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT | 25.19 | 0.00 | 01-JAN-06:15 | 2061.68 | 29-JUL-16:30 |
EnergyTransfer:Zone:F3 N2 APARTMENT | 25.41 | 0.04 | 18-DEC-03:15 | 2051.17 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT | 0.21 | 0.00 | 01-JAN-00:15 | 1114.35 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT | 25.20 | 0.00 | 01-JAN-06:15 | 2051.17 | 29-JUL-16:30 |
EnergyTransfer:Zone:F3 S1 APARTMENT | 31.89 | 0.05 | 17-DEC-21:00 | 2637.42 | 21-FEB-14:45 |
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT | 0.03 | 0.00 | 01-JAN-00:15 | 101.62 | 18-MAR-05:15 |
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT | 31.86 | 0.00 | 01-JAN-06:15 | 2637.42 | 21-FEB-14:45 |
EnergyTransfer:Zone:F3 S2 APARTMENT | 31.98 | 0.09 | 19-DEC-19:45 | 2636.10 | 21-FEB-14:45 |
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT | 0.03 | 0.00 | 01-JAN-00:15 | 101.17 | 18-MAR-05:15 |
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT | 31.95 | 0.00 | 01-JAN-06:15 | 2636.10 | 21-FEB-14:45 |
EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F4 SW APARTMENT | 40.05 | 0.02 | 23-JAN-02:45 | 3992.31 | 07-NOV-15:00 |
Heating:EnergyTransfer:Zone:F4 SW APARTMENT | 0.36 | 0.00 | 01-JAN-00:15 | 863.76 | 04-FEB-06:00 |
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT | 39.69 | 0.00 | 01-JAN-06:15 | 3992.31 | 07-NOV-15:00 |
EnergyTransfer:Zone:F4 NW APARTMENT | 33.64 | 0.01 | 27-NOV-00:15 | 3502.25 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F4 NW APARTMENT | 0.78 | 0.00 | 01-JAN-00:15 | 1582.34 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT | 32.86 | 0.00 | 01-JAN-06:15 | 3502.25 | 29-JUL-16:30 |
EnergyTransfer:Zone:F4 SE APARTMENT | 40.21 | 0.01 | 27-NOV-10:45 | 3376.49 | 07-NOV-15:00 |
Heating:EnergyTransfer:Zone:F4 SE APARTMENT | 0.23 | 0.00 | 01-JAN-00:15 | 920.71 | 04-FEB-06:00 |
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT | 39.98 | 0.00 | 01-JAN-06:15 | 3376.49 | 07-NOV-15:00 |
EnergyTransfer:Zone:F4 NE APARTMENT | 33.67 | 0.01 | 02-MAR-04:45 | 2875.16 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F4 NE APARTMENT | 0.52 | 0.00 | 01-JAN-00:15 | 1170.42 | 04-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT | 33.14 | 0.00 | 01-JAN-06:15 | 2875.16 | 29-JUL-16:30 |
EnergyTransfer:Zone:F4 N1 APARTMENT | 25.85 | 0.01 | 05-JAN-07:45 | 2084.05 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT | 0.22 | 0.00 | 01-JAN-00:15 | 1281.70 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT | 25.62 | 0.00 | 01-JAN-06:15 | 2084.05 | 29-JUL-16:30 |
EnergyTransfer:Zone:F4 N2 APARTMENT | 25.86 | 0.01 | 21-MAR-23:00 | 2078.44 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT | 0.22 | 0.00 | 01-JAN-00:15 | 1277.88 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT | 25.64 | 0.00 | 01-JAN-06:15 | 2078.44 | 29-JUL-16:30 |
EnergyTransfer:Zone:F4 S1 APARTMENT | 32.21 | 0.12 | 16-JAN-19:30 | 2688.99 | 21-FEB-14:45 |
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT | 0.04 | 0.00 | 01-JAN-00:15 | 111.57 | 18-MAR-05:15 |
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT | 32.17 | 0.00 | 01-JAN-06:15 | 2688.99 | 21-FEB-14:45 |
EnergyTransfer:Zone:F4 S2 APARTMENT | 32.26 | 0.05 | 18-APR-06:45 | 2705.63 | 21-FEB-14:45 |
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT | 0.04 | 0.00 | 01-JAN-00:15 | 111.33 | 18-MAR-05:15 |
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT | 32.23 | 0.00 | 01-JAN-06:15 | 2705.63 | 21-FEB-14:45 |
EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M SW APARTMENT | 40.54 | 0.01 | 22-FEB-04:15 | 4001.92 | 07-NOV-15:00 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.39 | 0.00 | 01-JAN-00:15 | 959.74 | 04-FEB-06:00 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 40.15 | 0.00 | 01-JAN-06:15 | 4001.92 | 07-NOV-15:00 |
EnergyTransfer:Zone:M NW APARTMENT | 34.31 | 0.05 | 21-DEC-00:15 | 3536.81 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 0.83 | 0.00 | 01-JAN-00:15 | 1711.87 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 33.48 | 0.00 | 01-JAN-06:15 | 3536.81 | 29-JUL-16:30 |
EnergyTransfer:Zone:M SE APARTMENT | 40.66 | 0.04 | 17-JAN-00:45 | 3416.81 | 07-NOV-14:45 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.26 | 0.00 | 01-JAN-00:15 | 1021.88 | 04-FEB-05:00 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 40.40 | 0.00 | 01-JAN-06:15 | 3416.81 | 07-NOV-14:45 |
EnergyTransfer:Zone:M NE APARTMENT | 34.31 | 0.04 | 18-JAN-03:45 | 2918.72 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 0.56 | 0.00 | 01-JAN-00:15 | 1277.76 | 04-FEB-19:15 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 33.74 | 0.00 | 01-JAN-06:15 | 2918.72 | 29-JUL-16:30 |
EnergyTransfer:Zone:M N1 APARTMENT | 26.54 | 0.01 | 18-DEC-02:15 | 2121.46 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.25 | 0.00 | 01-JAN-00:15 | 1407.10 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 26.30 | 0.00 | 01-JAN-06:15 | 2121.46 | 29-JUL-16:30 |
EnergyTransfer:Zone:M N2 APARTMENT | 26.55 | 0.02 | 12-FEB-07:00 | 2115.94 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.24 | 0.00 | 01-JAN-00:15 | 1404.11 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 26.31 | 0.00 | 01-JAN-06:15 | 2115.94 | 29-JUL-16:30 |
EnergyTransfer:Zone:M S1 APARTMENT | 32.78 | 0.01 | 05-FEB-23:30 | 2748.88 | 21-FEB-14:45 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.05 | 0.00 | 01-JAN-00:15 | 123.68 | 18-MAR-05:15 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 32.73 | 0.00 | 01-JAN-06:15 | 2748.88 | 21-FEB-14:45 |
EnergyTransfer:Zone:M S2 APARTMENT | 32.83 | 0.01 | 16-MAR-14:15 | 2740.62 | 21-FEB-14:45 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.05 | 0.00 | 01-JAN-00:15 | 211.04 | 04-FEB-06:00 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 32.78 | 0.00 | 01-JAN-06:15 | 2740.62 | 21-FEB-14:45 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F6 SW APARTMENT | 39.59 | 0.05 | 02-MAR-05:30 | 3952.83 | 07-NOV-15:00 |
Heating:EnergyTransfer:Zone:F6 SW APARTMENT | 0.45 | 0.00 | 01-JAN-00:15 | 1101.27 | 04-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT | 39.14 | 0.00 | 01-JAN-06:15 | 3952.83 | 07-NOV-15:00 |
EnergyTransfer:Zone:F6 NW APARTMENT | 33.59 | 0.08 | 01-MAR-20:15 | 3511.32 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F6 NW APARTMENT | 0.92 | 0.00 | 01-JAN-00:15 | 1870.23 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT | 32.67 | 0.00 | 01-JAN-06:15 | 3511.32 | 29-JUL-16:30 |
EnergyTransfer:Zone:F6 SE APARTMENT | 39.66 | 0.05 | 16-JAN-06:00 | 3396.13 | 07-NOV-14:45 |
Heating:EnergyTransfer:Zone:F6 SE APARTMENT | 0.30 | 0.00 | 01-JAN-00:15 | 1159.64 | 04-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT | 39.36 | 0.00 | 01-JAN-06:15 | 3396.13 | 07-NOV-14:45 |
EnergyTransfer:Zone:F6 NE APARTMENT | 33.55 | 0.01 | 10-JAN-03:15 | 2902.19 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F6 NE APARTMENT | 0.64 | 0.00 | 01-JAN-00:15 | 1434.65 | 04-FEB-19:15 |
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT | 32.91 | 0.00 | 01-JAN-06:15 | 2902.19 | 29-JUL-16:30 |
EnergyTransfer:Zone:F6 N1 APARTMENT | 25.81 | 0.10 | 01-FEB-01:00 | 2100.11 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT | 0.29 | 0.00 | 01-JAN-00:15 | 1586.67 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT | 25.52 | 0.00 | 01-JAN-06:15 | 2100.11 | 29-JUL-16:30 |
EnergyTransfer:Zone:F6 N2 APARTMENT | 25.82 | 0.11 | 01-FEB-10:45 | 2094.70 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT | 0.28 | 0.00 | 01-JAN-00:15 | 1583.40 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT | 25.54 | 0.00 | 01-JAN-06:15 | 2094.70 | 29-JUL-16:30 |
EnergyTransfer:Zone:F6 S1 APARTMENT | 31.82 | 0.09 | 16-MAR-20:30 | 2704.01 | 22-FEB-14:00 |
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT | 0.06 | 0.00 | 01-JAN-00:15 | 210.93 | 04-FEB-04:30 |
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT | 31.76 | 0.00 | 01-JAN-06:15 | 2704.01 | 22-FEB-14:00 |
EnergyTransfer:Zone:F6 S2 APARTMENT | 31.87 | 0.07 | 16-JAN-20:30 | 2716.53 | 22-FEB-14:15 |
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT | 0.06 | 0.00 | 01-JAN-00:15 | 180.39 | 12-NOV-09:45 |
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT | 31.81 | 0.00 | 01-JAN-06:15 | 2716.53 | 22-FEB-14:15 |
EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F7 SW APARTMENT | 39.17 | 0.01 | 23-FEB-03:00 | 3926.38 | 07-NOV-15:00 |
Heating:EnergyTransfer:Zone:F7 SW APARTMENT | 0.50 | 0.00 | 01-JAN-00:15 | 1213.97 | 04-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT | 38.67 | 0.00 | 01-JAN-06:15 | 3926.38 | 07-NOV-15:00 |
EnergyTransfer:Zone:F7 NW APARTMENT | 33.37 | 0.24 | 16-NOV-07:00 | 3507.31 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F7 NW APARTMENT | 1.00 | 0.00 | 01-JAN-00:15 | 1998.72 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT | 32.37 | 0.00 | 01-JAN-06:15 | 3507.31 | 29-JUL-16:30 |
EnergyTransfer:Zone:F7 SE APARTMENT | 39.21 | 0.08 | 22-JAN-02:00 | 3389.47 | 07-NOV-14:30 |
Heating:EnergyTransfer:Zone:F7 SE APARTMENT | 0.34 | 0.00 | 01-JAN-00:15 | 1264.17 | 04-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT | 38.88 | 0.00 | 01-JAN-06:15 | 3389.47 | 07-NOV-14:30 |
EnergyTransfer:Zone:F7 NE APARTMENT | 33.31 | 0.06 | 09-JAN-01:30 | 2905.65 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F7 NE APARTMENT | 0.71 | 0.00 | 01-JAN-00:15 | 1560.31 | 04-FEB-19:15 |
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT | 32.59 | 0.00 | 01-JAN-06:15 | 2905.65 | 29-JUL-16:30 |
EnergyTransfer:Zone:F7 N1 APARTMENT | 25.57 | 0.04 | 01-FEB-00:45 | 2099.02 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT | 0.33 | 0.00 | 01-JAN-00:15 | 1711.12 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT | 25.25 | 0.00 | 01-JAN-06:15 | 2099.02 | 29-JUL-16:30 |
EnergyTransfer:Zone:F7 N2 APARTMENT | 25.58 | 0.04 | 17-DEC-24:00 | 2093.70 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT | 0.32 | 0.00 | 01-JAN-00:15 | 1708.04 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT | 25.26 | 0.00 | 01-JAN-06:15 | 2093.70 | 29-JUL-16:30 |
EnergyTransfer:Zone:F7 S1 APARTMENT | 31.40 | 0.02 | 27-DEC-21:45 | 2684.31 | 22-FEB-16:30 |
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT | 0.07 | 0.00 | 01-JAN-00:15 | 237.43 | 04-FEB-06:00 |
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT | 31.33 | 0.00 | 01-JAN-06:15 | 2684.31 | 22-FEB-16:30 |
EnergyTransfer:Zone:F7 S2 APARTMENT | 31.45 | 0.04 | 20-JAN-13:00 | 2684.69 | 22-FEB-14:15 |
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT | 0.07 | 0.00 | 01-JAN-00:15 | 243.13 | 04-FEB-06:00 |
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT | 31.38 | 0.00 | 01-JAN-06:15 | 2684.69 | 22-FEB-14:15 |
EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F8 SW APARTMENT | 39.05 | 0.03 | 26-JAN-03:30 | 3910.06 | 07-NOV-15:00 |
Heating:EnergyTransfer:Zone:F8 SW APARTMENT | 0.55 | 0.00 | 01-JAN-00:15 | 1309.17 | 04-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT | 38.50 | 0.00 | 01-JAN-06:15 | 3910.06 | 07-NOV-15:00 |
EnergyTransfer:Zone:F8 NW APARTMENT | 33.42 | 0.06 | 20-DEC-20:30 | 3516.06 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F8 NW APARTMENT | 1.08 | 0.00 | 01-JAN-00:15 | 2115.71 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT | 32.33 | 0.00 | 01-JAN-06:15 | 3516.06 | 29-JUL-16:30 |
EnergyTransfer:Zone:F8 SE APARTMENT | 39.06 | 0.05 | 30-JAN-16:15 | 3402.90 | 07-NOV-14:30 |
Heating:EnergyTransfer:Zone:F8 SE APARTMENT | 0.37 | 0.00 | 01-JAN-00:15 | 1348.78 | 04-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT | 38.68 | 0.00 | 01-JAN-06:15 | 3402.90 | 07-NOV-14:30 |
EnergyTransfer:Zone:F8 NE APARTMENT | 33.32 | 0.06 | 26-JAN-00:30 | 2920.97 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F8 NE APARTMENT | 0.78 | 0.00 | 01-JAN-00:15 | 1672.87 | 04-FEB-19:15 |
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT | 32.54 | 0.00 | 01-JAN-06:15 | 2920.97 | 29-JUL-16:30 |
EnergyTransfer:Zone:F8 N1 APARTMENT | 25.60 | 0.08 | 25-DEC-07:00 | 2110.21 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT | 0.37 | 0.00 | 01-JAN-00:15 | 1827.02 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT | 25.24 | 0.00 | 01-JAN-06:15 | 2110.21 | 29-JUL-16:30 |
EnergyTransfer:Zone:F8 N2 APARTMENT | 25.61 | 0.20 | 19-DEC-03:00 | 2104.98 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT | 0.36 | 0.00 | 01-JAN-00:15 | 1822.90 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT | 25.25 | 0.00 | 01-JAN-06:15 | 2104.98 | 29-JUL-16:30 |
EnergyTransfer:Zone:F8 S1 APARTMENT | 31.27 | 0.01 | 01-FEB-02:30 | 2748.62 | 22-FEB-12:45 |
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT | 0.08 | 0.00 | 01-JAN-00:15 | 341.54 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT | 31.19 | 0.00 | 01-JAN-06:15 | 2748.62 | 22-FEB-12:45 |
EnergyTransfer:Zone:F8 S2 APARTMENT | 31.32 | 0.01 | 25-DEC-08:00 | 2764.28 | 22-FEB-12:45 |
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT | 0.08 | 0.00 | 01-JAN-00:15 | 342.20 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT | 31.24 | 0.00 | 01-JAN-06:15 | 2764.28 | 22-FEB-12:45 |
EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F9 SW APARTMENT | 39.84 | 0.15 | 21-MAR-12:30 | 3959.21 | 07-NOV-15:00 |
Heating:EnergyTransfer:Zone:F9 SW APARTMENT | 0.64 | 0.00 | 01-JAN-00:15 | 1434.52 | 04-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT | 39.21 | 0.00 | 01-JAN-06:15 | 3959.21 | 07-NOV-15:00 |
EnergyTransfer:Zone:F9 NW APARTMENT | 34.36 | 0.16 | 27-NOV-03:15 | 3620.48 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F9 NW APARTMENT | 1.22 | 0.00 | 01-JAN-00:15 | 2257.48 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT | 33.14 | 0.00 | 01-JAN-06:15 | 3620.48 | 29-JUL-16:30 |
EnergyTransfer:Zone:F9 SE APARTMENT | 39.80 | 0.01 | 31-JAN-02:30 | 3467.84 | 07-NOV-14:30 |
Heating:EnergyTransfer:Zone:F9 SE APARTMENT | 0.43 | 0.00 | 01-JAN-00:15 | 1476.34 | 04-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT | 39.37 | 0.00 | 01-JAN-06:15 | 3467.84 | 07-NOV-14:30 |
EnergyTransfer:Zone:F9 NE APARTMENT | 34.21 | 0.00 | 09-JAN-03:15 | 3029.51 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F9 NE APARTMENT | 0.88 | 0.00 | 01-JAN-00:15 | 1774.66 | 03-FEB-16:30 |
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT | 33.33 | 0.00 | 01-JAN-06:15 | 3029.51 | 29-JUL-16:30 |
EnergyTransfer:Zone:F9 N1 APARTMENT | 26.45 | 0.15 | 18-APR-13:00 | 2203.49 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT | 0.44 | 0.00 | 01-JAN-00:15 | 1953.02 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT | 26.01 | 0.00 | 01-JAN-06:15 | 2203.49 | 29-JUL-16:30 |
EnergyTransfer:Zone:F9 N2 APARTMENT | 26.45 | 0.17 | 31-DEC-02:45 | 2198.52 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT | 0.44 | 0.00 | 01-JAN-00:15 | 1949.28 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT | 26.02 | 0.00 | 01-JAN-06:15 | 2198.52 | 29-JUL-16:30 |
EnergyTransfer:Zone:F9 S1 APARTMENT | 32.04 | 0.00 | 22-JAN-20:30 | 2712.02 | 22-FEB-12:45 |
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT | 0.11 | 0.00 | 01-JAN-00:15 | 503.26 | 12-NOV-10:00 |
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT | 31.93 | 0.00 | 01-JAN-06:15 | 2712.02 | 22-FEB-12:45 |
EnergyTransfer:Zone:F9 S2 APARTMENT | 32.03 | 0.01 | 21-JAN-12:00 | 2722.77 | 22-FEB-12:45 |
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT | 0.11 | 0.00 | 01-JAN-00:15 | 500.85 | 12-NOV-10:00 |
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT | 31.92 | 0.00 | 01-JAN-06:15 | 2722.77 | 22-FEB-12:45 |
EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:T SW APARTMENT | 42.07 | 0.17 | 01-NOV-03:30 | 4730.24 | 07-NOV-15:00 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 1.32 | 0.00 | 01-JAN-00:15 | 2101.27 | 04-FEB-05:00 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 40.75 | 0.00 | 01-JAN-04:00 | 4730.24 | 07-NOV-15:00 |
EnergyTransfer:Zone:T NW APARTMENT | 36.91 | 0.12 | 10-MAR-07:00 | 4358.60 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 1.92 | 0.00 | 01-JAN-00:15 | 2359.25 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 35.00 | 0.00 | 01-JAN-02:30 | 4358.60 | 29-JUL-16:30 |
EnergyTransfer:Zone:T SE APARTMENT | 41.85 | 0.44 | 22-MAR-06:45 | 4171.02 | 07-NOV-14:15 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 1.05 | 0.00 | 01-JAN-00:15 | 2131.09 | 04-FEB-05:00 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 40.80 | 0.00 | 01-JAN-05:00 | 4171.02 | 07-NOV-14:15 |
EnergyTransfer:Zone:T NE APARTMENT | 36.59 | 0.41 | 07-NOV-05:15 | 3629.33 | 29-JUL-16:15 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 1.54 | 0.00 | 01-JAN-00:15 | 2274.88 | 04-FEB-05:00 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 35.05 | 0.00 | 01-JAN-02:30 | 3629.33 | 29-JUL-16:15 |
EnergyTransfer:Zone:T N1 APARTMENT | 28.80 | 0.00 | 21-JAN-04:30 | 2798.27 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 0.77 | 0.00 | 01-JAN-00:15 | 2078.76 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 28.04 | 0.00 | 01-JAN-06:15 | 2798.27 | 29-JUL-16:30 |
EnergyTransfer:Zone:T N2 APARTMENT | 28.81 | 0.01 | 11-JAN-04:30 | 2774.50 | 29-JUL-16:30 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 0.76 | 0.00 | 01-JAN-00:15 | 2066.69 | 05-FEB-09:30 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 28.05 | 0.00 | 01-JAN-06:15 | 2774.50 | 29-JUL-16:30 |
EnergyTransfer:Zone:T S1 APARTMENT | 34.27 | 0.00 | 20-MAR-23:45 | 3478.41 | 22-FEB-12:45 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 0.39 | 0.00 | 01-JAN-00:15 | 1108.91 | 04-FEB-05:00 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 33.88 | 0.00 | 01-JAN-06:15 | 3478.41 | 22-FEB-12:45 |
EnergyTransfer:Zone:T S2 APARTMENT | 34.30 | 0.04 | 18-JAN-02:45 | 3496.32 | 22-FEB-12:45 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 0.39 | 0.00 | 01-JAN-00:15 | 1112.15 | 04-FEB-05:00 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 33.91 | 0.00 | 01-JAN-06:15 | 3496.32 | 22-FEB-12:45 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Plant | 628.03 | 332.83 | 23-JUL-01:15 | 99545.43 | 04-FEB-06:15 |
WaterSystems:EnergyTransfer | 626.05 | 332.83 | 23-JUL-01:15 | 41388.00 | 19-JAN-07:45 |
sub cat:WaterSystems:EnergyTransfer | 626.05 | 332.83 | 23-JUL-01:15 | 41388.00 | 19-JAN-07:45 |
EnergyTransfer:HVAC | 5176.28 | 0.00 | 01-JAN-06:15 | 365153.16 | 29-NOV-11:45 |
CoolingCoils:EnergyTransfer | 5168.71 | 0.00 | 01-JAN-06:15 | 365153.16 | 29-NOV-11:45 |
HeatingCoils:EnergyTransfer | 7.57 | 0.00 | 01-JAN-00:15 | 84029.37 | 04-FEB-06:00 |
PlantLoopHeatingDemand:HVAC | 5.80 | 0.00 | 01-JAN-00:15 | 64013.05 | 04-FEB-06:00 |
HeatingCoils:PlantLoopHeatingDemand | 5.80 | 0.00 | 01-JAN-00:15 | 64013.05 | 04-FEB-06:00 |
Boilers:EnergyTransfer | 1.98 | 0.00 | 01-JAN-00:15 | 61106.62 | 04-FEB-06:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2015-09-09 19:12:00
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 0.577 | -24.505 | 0.000 | 0.000 | 3.563 | 1.087 | 12.213 | 24.068 | 0.000 | 1.439 | 0.000 | 0.000 | -3.540 | 0.000 | -2.909 | -11.992 |
G NW APARTMENT | 1.048 | -19.799 | 0.000 | 0.000 | 3.577 | 1.087 | 12.213 | 16.585 | 0.000 | 1.423 | 0.000 | 0.000 | -3.408 | 0.000 | -2.586 | -10.139 |
OFFICE | 0.218 | -35.671 | 0.000 | 0.000 | 0.503 | 29.882 | 9.495 | 24.183 | 0.000 | 0.941 | 0.000 | 0.000 | -3.696 | 0.000 | -0.747 | -25.108 |
G NE APARTMENT | 0.762 | -20.038 | 0.000 | 0.000 | 3.584 | 1.087 | 12.213 | 16.878 | 0.000 | 1.423 | 0.000 | 0.000 | -3.238 | 0.000 | -2.559 | -10.112 |
G N1 APARTMENT | 0.410 | -13.902 | 0.000 | 0.000 | 3.585 | 1.087 | 12.213 | 7.692 | 0.000 | 1.051 | 0.000 | 0.000 | -1.982 | 0.000 | -2.133 | -8.020 |
G N2 APARTMENT | 0.404 | -13.917 | 0.000 | 0.000 | 3.586 | 1.087 | 12.213 | 7.690 | 0.000 | 1.051 | 0.000 | 0.000 | -1.980 | 0.000 | -2.131 | -8.003 |
G S1 APARTMENT | 0.068 | -18.604 | 0.000 | 0.000 | 3.560 | 1.087 | 12.213 | 15.225 | 0.000 | 1.039 | 0.000 | 0.000 | -2.117 | 0.000 | -2.550 | -9.921 |
G S2 APARTMENT | 0.070 | -19.137 | 0.000 | 0.000 | 3.559 | 1.087 | 12.213 | 15.208 | 0.000 | 1.045 | 0.000 | 0.000 | -2.129 | 0.000 | -2.575 | -9.338 |
F2 SW APARTMENT | 0.345 | -37.893 | 0.000 | 0.000 | 3.537 | 1.087 | 12.213 | 22.836 | 0.000 | 1.947 | 3.932 | 0.000 | -4.207 | 0.000 | -3.796 | -0.000 |
F2 NW APARTMENT | 0.770 | -30.696 | 0.000 | 0.000 | 3.554 | 1.087 | 12.213 | 15.622 | 0.000 | 1.922 | 3.066 | 0.000 | -4.092 | 0.000 | -3.445 | -0.000 |
F2 SE APARTMENT | 0.226 | -40.481 | 0.000 | 0.000 | 3.535 | 1.087 | 12.213 | 23.080 | 0.000 | 1.944 | 6.430 | 0.000 | -4.186 | 0.000 | -3.849 | -0.000 |
F2 NE APARTMENT | 0.512 | -31.018 | 0.000 | 0.000 | 3.560 | 1.087 | 12.213 | 15.865 | 0.000 | 1.922 | 3.161 | 0.000 | -3.886 | 0.000 | -3.416 | -0.000 |
F2 N1 APARTMENT | 0.227 | -23.140 | 0.000 | 0.000 | 3.557 | 1.087 | 12.213 | 7.109 | 0.000 | 1.389 | 2.930 | 0.000 | -2.461 | 0.000 | -2.910 | -0.000 |
F2 N2 APARTMENT | 0.224 | -23.156 | 0.000 | 0.000 | 3.557 | 1.087 | 12.213 | 7.108 | 0.000 | 1.389 | 2.946 | 0.000 | -2.458 | 0.000 | -2.908 | -0.000 |
F2 S1 APARTMENT | 0.032 | -30.026 | 0.000 | 0.000 | 3.529 | 1.087 | 12.213 | 14.394 | 0.000 | 1.342 | 3.300 | 0.000 | -2.523 | 0.000 | -3.348 | -0.000 |
F2 S2 APARTMENT | 0.032 | -30.231 | 0.000 | 0.000 | 3.529 | 1.087 | 12.213 | 14.392 | 0.000 | 1.347 | 3.511 | 0.000 | -2.526 | 0.000 | -3.354 | -0.000 |
F3 SW APARTMENT | 0.331 | -39.560 | 0.000 | 0.000 | 3.535 | 1.087 | 12.213 | 22.351 | 0.000 | 2.503 | 6.061 | 0.000 | -4.310 | 0.000 | -4.210 | -0.001 |
F3 NW APARTMENT | 0.742 | -32.539 | 0.000 | 0.000 | 3.552 | 1.087 | 12.213 | 15.298 | 0.000 | 2.468 | 5.255 | 0.000 | -4.224 | 0.000 | -3.852 | -0.000 |
F3 SE APARTMENT | 0.212 | -40.084 | 0.000 | 0.000 | 3.537 | 1.087 | 12.213 | 22.640 | 0.000 | 2.479 | 6.347 | 0.000 | -4.217 | 0.000 | -4.212 | -0.001 |
F3 NE APARTMENT | 0.493 | -32.838 | 0.000 | 0.000 | 3.557 | 1.087 | 12.213 | 15.518 | 0.000 | 2.468 | 5.331 | 0.000 | -4.006 | 0.000 | -3.822 | -0.000 |
F3 N1 APARTMENT | 0.211 | -25.190 | 0.000 | 0.000 | 3.552 | 1.087 | 12.213 | 6.952 | 0.000 | 1.836 | 5.169 | 0.000 | -2.561 | 0.000 | -3.267 | 0.000 |
F3 N2 APARTMENT | 0.208 | -25.204 | 0.000 | 0.000 | 3.552 | 1.087 | 12.213 | 6.950 | 0.000 | 1.836 | 5.182 | 0.000 | -2.559 | 0.000 | -3.265 | 0.000 |
F3 S1 APARTMENT | 0.030 | -31.861 | 0.000 | 0.000 | 3.524 | 1.087 | 12.213 | 14.062 | 0.000 | 1.712 | 5.534 | 0.000 | -2.599 | 0.000 | -3.702 | -0.000 |
F3 S2 APARTMENT | 0.030 | -31.945 | 0.000 | 0.000 | 3.525 | 1.087 | 12.213 | 14.063 | 0.000 | 1.719 | 5.609 | 0.000 | -2.598 | 0.000 | -3.702 | -0.000 |
F4 SW APARTMENT | 0.357 | -39.692 | 0.000 | 0.000 | 3.536 | 1.087 | 12.213 | 22.032 | 0.000 | 2.739 | 6.516 | 0.000 | -4.345 | 0.000 | -4.442 | -0.000 |
F4 NW APARTMENT | 0.779 | -32.863 | 0.000 | 0.000 | 3.552 | 1.087 | 12.213 | 15.101 | 0.000 | 2.700 | 5.777 | 0.000 | -4.272 | 0.000 | -4.073 | 0.000 |
F4 SE APARTMENT | 0.233 | -39.978 | 0.000 | 0.000 | 3.538 | 1.087 | 12.213 | 22.315 | 0.000 | 2.711 | 6.553 | 0.000 | -4.238 | 0.000 | -4.434 | -0.000 |
F4 NE APARTMENT | 0.524 | -33.141 | 0.000 | 0.000 | 3.557 | 1.087 | 12.213 | 15.303 | 0.000 | 2.699 | 5.845 | 0.000 | -4.046 | 0.000 | -4.041 | -0.000 |
F4 N1 APARTMENT | 0.224 | -25.623 | 0.000 | 0.000 | 3.551 | 1.087 | 12.213 | 6.862 | 0.000 | 1.996 | 5.732 | 0.000 | -2.600 | 0.000 | -3.442 | 0.000 |
F4 N2 APARTMENT | 0.222 | -25.636 | 0.000 | 0.000 | 3.552 | 1.087 | 12.213 | 6.861 | 0.000 | 1.995 | 5.744 | 0.000 | -2.597 | 0.000 | -3.440 | 0.000 |
F4 S1 APARTMENT | 0.037 | -32.169 | 0.000 | 0.000 | 3.524 | 1.087 | 12.213 | 13.855 | 0.000 | 1.863 | 6.093 | 0.000 | -2.624 | 0.000 | -3.879 | -0.000 |
F4 S2 APARTMENT | 0.036 | -32.225 | 0.000 | 0.000 | 3.525 | 1.087 | 12.213 | 13.856 | 0.000 | 1.870 | 6.140 | 0.000 | -2.622 | 0.000 | -3.879 | -0.001 |
M SW APARTMENT | 0.392 | -40.152 | 0.000 | 0.000 | 3.537 | 1.087 | 12.213 | 21.767 | 0.000 | 2.926 | 7.311 | 0.000 | -4.386 | 0.000 | -4.694 | -0.001 |
M NW APARTMENT | 0.827 | -33.482 | 0.000 | 0.000 | 3.553 | 1.087 | 12.213 | 14.931 | 0.000 | 2.884 | 6.617 | 0.000 | -4.319 | 0.000 | -4.311 | 0.000 |
M SE APARTMENT | 0.260 | -40.395 | 0.000 | 0.000 | 3.539 | 1.087 | 12.213 | 22.040 | 0.000 | 2.897 | 7.317 | 0.000 | -4.273 | 0.000 | -4.683 | -0.000 |
M NE APARTMENT | 0.564 | -33.741 | 0.000 | 0.000 | 3.558 | 1.087 | 12.213 | 15.120 | 0.000 | 2.883 | 6.679 | 0.000 | -4.086 | 0.000 | -4.276 | 0.000 |
M N1 APARTMENT | 0.247 | -26.297 | 0.000 | 0.000 | 3.552 | 1.087 | 12.213 | 6.784 | 0.000 | 2.122 | 6.568 | 0.000 | -2.635 | 0.000 | -3.640 | 0.000 |
M N2 APARTMENT | 0.244 | -26.309 | 0.000 | 0.000 | 3.552 | 1.087 | 12.213 | 6.783 | 0.000 | 2.121 | 6.579 | 0.000 | -2.632 | 0.000 | -3.637 | 0.000 |
M S1 APARTMENT | 0.046 | -32.733 | 0.000 | 0.000 | 3.525 | 1.087 | 12.213 | 13.684 | 0.000 | 1.989 | 6.925 | 0.000 | -2.649 | 0.000 | -4.086 | -0.000 |
M S2 APARTMENT | 0.046 | -32.783 | 0.000 | 0.000 | 3.526 | 1.087 | 12.213 | 13.685 | 0.000 | 1.995 | 6.964 | 0.000 | -2.647 | 0.000 | -4.085 | -0.000 |
F6 SW APARTMENT | 0.447 | -39.141 | 0.000 | 0.000 | 3.540 | 1.087 | 12.213 | 21.601 | 0.000 | 3.081 | 6.418 | 0.000 | -4.365 | 0.000 | -4.880 | -0.000 |
F6 NW APARTMENT | 0.920 | -32.672 | 0.000 | 0.000 | 3.557 | 1.087 | 12.213 | 14.845 | 0.000 | 3.036 | 5.778 | 0.000 | -4.297 | 0.000 | -4.467 | 0.000 |
F6 SE APARTMENT | 0.300 | -39.361 | 0.000 | 0.000 | 3.542 | 1.087 | 12.213 | 21.865 | 0.000 | 3.050 | 6.420 | 0.000 | -4.250 | 0.000 | -4.867 | -0.000 |
F6 NE APARTMENT | 0.642 | -32.913 | 0.000 | 0.000 | 3.562 | 1.087 | 12.213 | 15.024 | 0.000 | 3.035 | 5.838 | 0.000 | -4.061 | 0.000 | -4.427 | 0.000 |
F6 N1 APARTMENT | 0.288 | -25.524 | 0.000 | 0.000 | 3.555 | 1.087 | 12.213 | 6.754 | 0.000 | 2.226 | 5.775 | 0.000 | -2.621 | 0.000 | -3.753 | 0.000 |
F6 N2 APARTMENT | 0.285 | -25.535 | 0.000 | 0.000 | 3.556 | 1.087 | 12.213 | 6.753 | 0.000 | 2.225 | 5.786 | 0.000 | -2.619 | 0.000 | -3.750 | 0.000 |
F6 S1 APARTMENT | 0.058 | -31.762 | 0.000 | 0.000 | 3.528 | 1.087 | 12.213 | 13.577 | 0.000 | 2.094 | 6.074 | 0.000 | -2.636 | 0.000 | -4.232 | -0.001 |
F6 S2 APARTMENT | 0.057 | -31.809 | 0.000 | 0.000 | 3.529 | 1.087 | 12.213 | 13.578 | 0.000 | 2.100 | 6.111 | 0.000 | -2.634 | 0.000 | -4.231 | -0.000 |
F7 SW APARTMENT | 0.496 | -38.674 | 0.000 | 0.000 | 3.542 | 1.087 | 12.213 | 21.440 | 0.000 | 3.213 | 6.095 | 0.000 | -4.364 | 0.000 | -5.046 | -0.000 |
F7 NW APARTMENT | 1.003 | -32.368 | 0.000 | 0.000 | 3.559 | 1.087 | 12.213 | 14.754 | 0.000 | 3.165 | 5.497 | 0.000 | -4.296 | 0.000 | -4.613 | 0.000 |
F7 SE APARTMENT | 0.338 | -38.876 | 0.000 | 0.000 | 3.544 | 1.087 | 12.213 | 21.697 | 0.000 | 3.180 | 6.095 | 0.000 | -4.246 | 0.000 | -5.031 | -0.001 |
F7 NE APARTMENT | 0.711 | -32.594 | 0.000 | 0.000 | 3.565 | 1.087 | 12.213 | 14.924 | 0.000 | 3.163 | 5.555 | 0.000 | -4.056 | 0.000 | -4.568 | -0.000 |
F7 N1 APARTMENT | 0.325 | -25.246 | 0.000 | 0.000 | 3.558 | 1.087 | 12.213 | 6.718 | 0.000 | 2.313 | 5.514 | 0.000 | -2.621 | 0.000 | -3.861 | 0.000 |
F7 N2 APARTMENT | 0.323 | -25.259 | 0.000 | 0.000 | 3.558 | 1.087 | 12.213 | 6.716 | 0.000 | 2.313 | 5.525 | 0.000 | -2.618 | 0.000 | -3.857 | 0.000 |
F7 S1 APARTMENT | 0.069 | -31.333 | 0.000 | 0.000 | 3.530 | 1.087 | 12.213 | 13.475 | 0.000 | 2.183 | 5.774 | 0.000 | -2.635 | 0.000 | -4.362 | -0.000 |
F7 S2 APARTMENT | 0.069 | -31.380 | 0.000 | 0.000 | 3.531 | 1.087 | 12.213 | 13.476 | 0.000 | 2.189 | 5.810 | 0.000 | -2.633 | 0.000 | -4.362 | -0.000 |
F8 SW APARTMENT | 0.546 | -38.499 | 0.000 | 0.000 | 3.544 | 1.087 | 12.213 | 21.288 | 0.000 | 3.335 | 6.071 | 0.000 | -4.373 | 0.000 | -5.211 | -0.000 |
F8 NW APARTMENT | 1.083 | -32.331 | 0.000 | 0.000 | 3.561 | 1.087 | 12.213 | 14.662 | 0.000 | 3.285 | 5.508 | 0.000 | -4.306 | 0.000 | -4.761 | 0.000 |
F8 SE APARTMENT | 0.374 | -38.684 | 0.000 | 0.000 | 3.546 | 1.087 | 12.213 | 21.539 | 0.000 | 3.302 | 6.071 | 0.000 | -4.252 | 0.000 | -5.195 | -0.000 |
F8 NE APARTMENT | 0.779 | -32.544 | 0.000 | 0.000 | 3.567 | 1.087 | 12.213 | 14.824 | 0.000 | 3.283 | 5.566 | 0.000 | -4.062 | 0.000 | -4.711 | -0.000 |
F8 N1 APARTMENT | 0.365 | -25.237 | 0.000 | 0.000 | 3.560 | 1.087 | 12.213 | 6.678 | 0.000 | 2.397 | 5.539 | 0.000 | -2.627 | 0.000 | -3.974 | 0.000 |
F8 N2 APARTMENT | 0.362 | -25.248 | 0.000 | 0.000 | 3.561 | 1.087 | 12.213 | 6.677 | 0.000 | 2.396 | 5.549 | 0.000 | -2.625 | 0.000 | -3.970 | 0.000 |
F8 S1 APARTMENT | 0.083 | -31.191 | 0.000 | 0.000 | 3.532 | 1.087 | 12.213 | 13.379 | 0.000 | 2.270 | 5.761 | 0.000 | -2.640 | 0.000 | -4.494 | -0.001 |
F8 S2 APARTMENT | 0.082 | -31.239 | 0.000 | 0.000 | 3.533 | 1.087 | 12.213 | 13.380 | 0.000 | 2.276 | 5.801 | 0.000 | -2.638 | 0.000 | -4.493 | -0.000 |
F9 SW APARTMENT | 0.635 | -39.209 | 0.000 | 0.000 | 3.546 | 1.087 | 12.213 | 21.125 | 0.000 | 3.483 | 6.880 | 0.000 | -4.401 | 0.000 | -5.359 | -0.000 |
F9 NW APARTMENT | 1.220 | -33.137 | 0.000 | 0.000 | 3.563 | 1.087 | 12.213 | 14.548 | 0.000 | 3.427 | 6.319 | 0.000 | -4.337 | 0.000 | -4.902 | 0.000 |
F9 SE APARTMENT | 0.433 | -39.365 | 0.000 | 0.000 | 3.549 | 1.087 | 12.213 | 21.367 | 0.000 | 3.448 | 6.884 | 0.000 | -4.276 | 0.000 | -5.340 | -0.001 |
F9 NE APARTMENT | 0.878 | -33.333 | 0.000 | 0.000 | 3.569 | 1.087 | 12.213 | 14.702 | 0.000 | 3.425 | 6.395 | 0.000 | -4.090 | 0.000 | -4.845 | -0.000 |
F9 N1 APARTMENT | 0.439 | -26.007 | 0.000 | 0.000 | 3.562 | 1.087 | 12.213 | 6.621 | 0.000 | 2.508 | 6.306 | 0.000 | -2.646 | 0.000 | -4.083 | 0.000 |
F9 N2 APARTMENT | 0.436 | -26.018 | 0.000 | 0.000 | 3.562 | 1.087 | 12.213 | 6.620 | 0.000 | 2.507 | 6.315 | 0.000 | -2.643 | 0.000 | -4.079 | 0.000 |
F9 S1 APARTMENT | 0.113 | -31.930 | 0.000 | 0.000 | 3.535 | 1.087 | 12.213 | 13.283 | 0.000 | 2.403 | 6.562 | 0.000 | -2.654 | 0.000 | -4.611 | -0.000 |
F9 S2 APARTMENT | 0.111 | -31.916 | 0.000 | 0.000 | 3.535 | 1.087 | 12.213 | 13.280 | 0.000 | 2.397 | 6.556 | 0.000 | -2.653 | 0.000 | -4.610 | -0.000 |
T SW APARTMENT | 1.318 | -40.745 | 0.000 | 0.000 | 3.560 | 1.087 | 12.213 | 20.423 | 0.000 | 3.574 | 8.111 | 0.000 | -4.124 | 0.000 | -5.416 | -0.001 |
T NW APARTMENT | 1.916 | -34.997 | 0.000 | 0.000 | 3.573 | 1.087 | 12.213 | 13.936 | 0.000 | 3.513 | 7.865 | 0.000 | -4.085 | 0.000 | -5.020 | 0.000 |
T SE APARTMENT | 1.046 | -40.804 | 0.000 | 0.000 | 3.564 | 1.087 | 12.213 | 20.664 | 0.000 | 3.550 | 8.090 | 0.000 | -4.008 | 0.000 | -5.402 | -0.000 |
T NE APARTMENT | 1.539 | -35.048 | 0.000 | 0.000 | 3.579 | 1.087 | 12.213 | 14.105 | 0.000 | 3.513 | 7.863 | 0.000 | -3.871 | 0.000 | -4.979 | -0.000 |
T N1 APARTMENT | 0.767 | -28.036 | 0.000 | 0.000 | 3.573 | 1.087 | 12.213 | 6.366 | 0.000 | 2.574 | 8.100 | 0.000 | -2.474 | 0.000 | -4.169 | -0.000 |
T N2 APARTMENT | 0.759 | -28.048 | 0.000 | 0.000 | 3.573 | 1.087 | 12.213 | 6.363 | 0.000 | 2.573 | 8.115 | 0.000 | -2.470 | 0.000 | -4.165 | -0.000 |
T S1 APARTMENT | 0.389 | -33.883 | 0.000 | 0.000 | 3.553 | 1.087 | 12.213 | 12.913 | 0.000 | 2.559 | 8.346 | 0.000 | -2.526 | 0.000 | -4.650 | -0.000 |
T S2 APARTMENT | 0.392 | -33.906 | 0.000 | 0.000 | 3.553 | 1.087 | 12.213 | 12.910 | 0.000 | 2.558 | 8.368 | 0.000 | -2.523 | 0.000 | -4.651 | -0.000 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 5.784 | 0.000 | 5.486 | 0.000 | 0.000 | -0.930 | 0.000 | -6.301 | -20.478 |
F2 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.655 | 0.000 | 0.096 | 0.000 | 0.000 | -0.626 | 0.000 | -0.273 | -18.292 |
F3 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.575 | 0.000 | 0.107 | 0.000 | 0.000 | -0.659 | 0.000 | -0.346 | -18.117 |
F4 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.521 | 0.000 | 0.114 | 0.000 | 0.000 | -0.678 | 0.000 | -0.398 | -17.998 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32.880 | 0.000 | 2.440 | 0.000 | 0.095 | 0.000 | 0.000 | -0.729 | 0.000 | -0.501 | -34.184 |
F6 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.467 | 0.000 | 0.131 | 0.000 | 0.000 | -0.683 | 0.000 | -0.461 | -17.893 |
F7 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.458 | 0.000 | 0.142 | 0.000 | 0.000 | -0.674 | 0.000 | -0.476 | -17.889 |
F8 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.439 | 0.000 | 0.147 | 0.000 | 0.000 | -0.675 | 0.000 | -0.498 | -17.854 |
F9 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.412 | 0.000 | 0.144 | 0.000 | 0.000 | -0.687 | 0.000 | -0.525 | -17.784 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 8.151 | 2.243 | 0.000 | 0.063 | 0.000 | 0.000 | -0.693 | 0.000 | -0.666 | -25.538 |
Total Facility | 35.617 | -2504.455 | 0.000 | 0.000 | 280.993 | 296.560 | 982.450 | 1183.592 | 0.000 | 197.667 | 434.130 | 0.000 | -273.758 | 0.000 | -334.135 | -298.674 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 30-SEP-14:30 | 0.00 | -3006.48 | 0.00 | 0.00 | 38.92 | 22.70 | 400.26 | 4255.39 | 0.00 | 98.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1809.68 |
G NW APARTMENT | 29-JUL-16:30 | 0.00 | -2929.98 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2824.45 | 0.00 | 142.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -775.07 |
OFFICE | 29-SEP-12:30 | 0.00 | -4140.51 | 0.00 | 0.00 | 65.20 | 2345.88 | 588.62 | 3165.29 | 0.00 | 81.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2106.10 |
G NE APARTMENT | 25-JUL-10:15 | 0.00 | -2297.95 | 0.00 | 0.00 | 40.65 | 12.97 | 412.03 | 2550.48 | 0.00 | 62.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -780.94 |
G N1 APARTMENT | 29-JUL-16:30 | 0.00 | -1608.60 | 0.00 | 0.00 | 84.58 | 64.86 | 588.62 | 1090.78 | 0.00 | 85.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -305.60 |
G N2 APARTMENT | 29-JUL-16:30 | 0.00 | -1595.26 | 0.00 | 0.00 | 84.53 | 64.86 | 588.62 | 1090.91 | 0.00 | 85.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -318.97 |
G S1 APARTMENT | 27-FEB-13:15 | 0.00 | -1903.64 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2845.77 | 0.00 | 272.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1657.13 |
G S2 APARTMENT | 27-FEB-13:15 | 0.00 | -1951.84 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2843.82 | 0.00 | 272.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1606.97 |
F2 SW APARTMENT | 07-NOV-15:15 | 0.00 | -3932.54 | 0.00 | 0.00 | 40.70 | 22.70 | 400.26 | 4021.17 | 0.00 | 42.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -595.16 |
F2 NW APARTMENT | 29-JUL-16:30 | 0.00 | -3473.09 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2772.82 | 0.00 | 204.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -242.17 |
F2 SE APARTMENT | 07-NOV-14:30 | 0.00 | -3517.83 | 0.00 | 0.00 | 40.49 | 12.97 | 382.60 | 2863.97 | 0.00 | 48.34 | 169.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 NE APARTMENT | 29-JUL-16:30 | 0.00 | -2818.80 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 1624.15 | 0.00 | 204.20 | 252.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 N1 APARTMENT | 29-JUL-16:30 | 0.00 | -2020.22 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 1073.49 | 0.00 | 123.05 | 85.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 N2 APARTMENT | 29-JUL-16:30 | 0.00 | -2009.72 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 1073.63 | 0.00 | 123.01 | 74.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 S1 APARTMENT | 22-FEB-14:00 | 0.00 | -2539.76 | 0.00 | 0.00 | 40.68 | 12.97 | 388.49 | 2979.87 | 0.00 | 18.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -901.25 |
F2 S2 APARTMENT | 22-FEB-14:00 | 0.00 | -2568.37 | 0.00 | 0.00 | 40.71 | 12.97 | 388.49 | 2979.65 | 0.00 | 19.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -872.54 |
F3 SW APARTMENT | 07-NOV-15:15 | 0.00 | -3988.34 | 0.00 | 0.00 | 40.71 | 22.70 | 400.26 | 3984.11 | 0.00 | 50.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -510.00 |
F3 NW APARTMENT | 29-JUL-16:30 | 0.00 | -3487.21 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2745.63 | 0.00 | 241.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -237.92 |
F3 SE APARTMENT | 07-NOV-15:00 | 0.00 | -3363.89 | 0.00 | 0.00 | 40.34 | 12.97 | 382.60 | 2557.94 | 0.00 | 36.86 | 333.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 NE APARTMENT | 29-JUL-16:30 | 0.00 | -2848.66 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 1618.04 | 0.00 | 241.26 | 251.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 N1 APARTMENT | 29-JUL-16:30 | 0.00 | -2061.77 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 1068.14 | 0.00 | 145.50 | 109.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 N2 APARTMENT | 29-JUL-16:30 | 0.00 | -2051.27 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 1068.28 | 0.00 | 145.45 | 99.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 S1 APARTMENT | 21-FEB-14:45 | 0.00 | -2636.39 | 0.00 | 0.00 | 40.67 | 12.97 | 382.60 | 2415.68 | 0.00 | 244.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -459.73 |
F3 S2 APARTMENT | 21-FEB-14:45 | 0.00 | -2635.07 | 0.00 | 0.00 | 40.72 | 12.97 | 382.60 | 2416.17 | 0.00 | 245.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -463.07 |
F4 SW APARTMENT | 07-NOV-15:00 | 0.00 | -3991.73 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 4123.99 | 0.00 | 41.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -610.34 |
F4 NW APARTMENT | 29-JUL-16:30 | 0.00 | -3502.38 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2724.75 | 0.00 | 269.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -229.71 |
F4 SE APARTMENT | 07-NOV-15:00 | 0.00 | -3375.95 | 0.00 | 0.00 | 40.40 | 12.97 | 382.60 | 2547.24 | 0.00 | 41.21 | 351.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 NE APARTMENT | 29-JUL-16:30 | 0.00 | -2875.32 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 1613.10 | 0.00 | 269.11 | 254.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 N1 APARTMENT | 29-JUL-16:30 | 0.00 | -2084.14 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 1064.09 | 0.00 | 162.32 | 119.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 N2 APARTMENT | 29-JUL-16:30 | 0.00 | -2078.53 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 1064.24 | 0.00 | 162.32 | 113.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 S1 APARTMENT | 21-FEB-14:45 | 0.00 | -2687.91 | 0.00 | 0.00 | 40.61 | 12.97 | 382.60 | 2380.38 | 0.00 | 258.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -387.04 |
F4 S2 APARTMENT | 21-FEB-14:45 | 0.00 | -2704.54 | 0.00 | 0.00 | 40.65 | 12.97 | 382.60 | 2380.84 | 0.00 | 261.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -374.31 |
M SW APARTMENT | 07-NOV-15:00 | 0.00 | -4001.31 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 4107.92 | 0.00 | 45.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -588.08 |
M NW APARTMENT | 29-JUL-16:30 | 0.00 | -3536.95 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2706.75 | 0.00 | 291.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -199.89 |
M SE APARTMENT | 07-NOV-14:45 | 0.00 | -3416.25 | 0.00 | 0.00 | 40.35 | 12.97 | 382.60 | 2681.87 | 0.00 | 55.98 | 242.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NE APARTMENT | 29-JUL-16:30 | 0.00 | -2918.89 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 1607.92 | 0.00 | 291.86 | 280.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N1 APARTMENT | 29-JUL-16:30 | 0.00 | -2121.55 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 1060.08 | 0.00 | 176.04 | 147.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 29-JUL-16:30 | 0.00 | -2116.03 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 1060.23 | 0.00 | 176.04 | 141.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | 21-FEB-14:45 | 0.00 | -2747.74 | 0.00 | 0.00 | 40.69 | 12.97 | 382.60 | 2354.99 | 0.00 | 278.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -322.07 |
M S2 APARTMENT | 21-FEB-14:45 | 0.00 | -2739.48 | 0.00 | 0.00 | 40.73 | 12.97 | 382.60 | 2355.42 | 0.00 | 279.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -331.37 |
F6 SW APARTMENT | 07-NOV-15:00 | 0.00 | -3952.20 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 4096.26 | 0.00 | 47.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -628.38 |
F6 NW APARTMENT | 29-JUL-16:30 | 0.00 | -3511.46 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 2693.77 | 0.00 | 311.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -231.83 |
F6 SE APARTMENT | 07-NOV-14:45 | 0.00 | -3395.55 | 0.00 | 0.00 | 40.46 | 12.97 | 382.60 | 2675.38 | 0.00 | 60.15 | 223.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 NE APARTMENT | 29-JUL-16:30 | 0.00 | -2902.36 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 1605.81 | 0.00 | 311.28 | 247.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 N1 APARTMENT | 29-JUL-16:30 | 0.00 | -2100.20 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 1058.23 | 0.00 | 187.75 | 115.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 N2 APARTMENT | 29-JUL-16:30 | 0.00 | -2094.79 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 1058.37 | 0.00 | 187.75 | 110.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 S1 APARTMENT | 22-FEB-14:00 | 0.00 | -2704.09 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2912.43 | 0.00 | 28.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -679.37 |
F6 S2 APARTMENT | 22-FEB-14:15 | 0.00 | -2716.61 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 2840.52 | 0.00 | 30.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -590.69 |
F7 SW APARTMENT | 07-NOV-15:00 | 0.00 | -3925.73 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 4084.93 | 0.00 | 50.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -645.97 |
F7 NW APARTMENT | 29-JUL-16:30 | 0.00 | -3507.44 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 2681.49 | 0.00 | 328.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -240.61 |
F7 SE APARTMENT | 07-NOV-14:30 | 0.00 | -3388.91 | 0.00 | 0.00 | 40.41 | 12.97 | 382.60 | 2786.20 | 0.00 | 75.94 | 90.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 NE APARTMENT | 29-JUL-16:30 | 0.00 | -2905.81 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 1602.97 | 0.00 | 328.32 | 236.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 N1 APARTMENT | 29-JUL-16:30 | 0.00 | -2099.11 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 1055.97 | 0.00 | 198.03 | 106.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 N2 APARTMENT | 29-JUL-16:30 | 0.00 | -2093.79 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 1056.11 | 0.00 | 198.03 | 101.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 S1 APARTMENT | 22-FEB-16:30 | 0.00 | -2683.58 | 0.00 | 0.00 | 48.90 | 45.40 | 470.89 | 1396.91 | 0.00 | 465.47 | 256.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 S2 APARTMENT | 22-FEB-14:15 | 0.00 | -2684.76 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 2831.13 | 0.00 | 31.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -614.65 |
F8 SW APARTMENT | 07-NOV-15:00 | 0.00 | -3909.39 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 4074.19 | 0.00 | 52.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -653.73 |
F8 NW APARTMENT | 29-JUL-16:30 | 0.00 | -3516.20 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 2669.83 | 0.00 | 343.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -235.44 |
F8 SE APARTMENT | 07-NOV-14:30 | 0.00 | -3402.32 | 0.00 | 0.00 | 40.52 | 12.97 | 382.60 | 2778.94 | 0.00 | 80.12 | 107.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 NE APARTMENT | 29-JUL-16:30 | 0.00 | -2921.13 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 1599.67 | 0.00 | 343.57 | 239.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 N1 APARTMENT | 29-JUL-16:30 | 0.00 | -2110.30 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 1053.44 | 0.00 | 207.23 | 111.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 N2 APARTMENT | 29-JUL-16:30 | 0.00 | -2105.07 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 1053.58 | 0.00 | 207.23 | 106.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 S1 APARTMENT | 22-FEB-12:45 | 0.00 | -2747.54 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 2935.25 | 0.00 | 337.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -985.39 |
F8 S2 APARTMENT | 22-FEB-12:45 | 0.00 | -2763.20 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 2934.97 | 0.00 | 338.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -970.02 |
F9 SW APARTMENT | 07-NOV-15:00 | 0.00 | -3958.51 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 4061.26 | 0.00 | 54.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -593.62 |
F9 NW APARTMENT | 29-JUL-16:30 | 0.00 | -3620.62 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 2653.74 | 0.00 | 357.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -128.77 |
F9 SE APARTMENT | 07-NOV-14:30 | 0.00 | -3467.23 | 0.00 | 0.00 | 40.58 | 12.97 | 382.60 | 2767.95 | 0.00 | 83.44 | 179.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 NE APARTMENT | 29-JUL-16:30 | 0.00 | -3029.68 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 1591.13 | 0.00 | 357.41 | 342.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 N1 APARTMENT | 29-JUL-16:30 | 0.00 | -2203.59 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 1047.79 | 0.00 | 215.57 | 201.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 N2 APARTMENT | 29-JUL-16:30 | 0.00 | -2198.62 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 1047.92 | 0.00 | 215.57 | 196.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 S1 APARTMENT | 22-FEB-12:45 | 0.00 | -2710.92 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 2924.31 | 0.00 | 345.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1018.72 |
F9 S2 APARTMENT | 22-FEB-12:45 | 0.00 | -2721.68 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 2923.99 | 0.00 | 345.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1007.65 |
T SW APARTMENT | 07-NOV-15:00 | 0.00 | -4729.53 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 3974.13 | 0.00 | 56.28 | 262.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 29-JUL-16:30 | 0.00 | -4358.81 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 2567.84 | 0.00 | 370.06 | 682.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SE APARTMENT | 07-NOV-14:15 | 0.00 | -4170.39 | 0.00 | 0.00 | 40.46 | 12.97 | 382.60 | 2768.78 | 0.00 | 100.74 | 864.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 29-JUL-16:10 | 0.00 | -3631.43 | 0.00 | 0.00 | 84.78 | 64.86 | 588.62 | 1572.58 | 0.00 | 380.29 | 940.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 29-JUL-16:30 | 0.00 | -2798.47 | 0.00 | 0.00 | 84.45 | 64.86 | 588.62 | 1009.76 | 0.00 | 221.77 | 829.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 29-JUL-16:30 | 0.00 | -2774.71 | 0.00 | 0.00 | 84.39 | 64.86 | 588.62 | 1010.04 | 0.00 | 221.49 | 805.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 22-FEB-12:45 | 0.00 | -3477.09 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 2870.48 | 0.00 | 349.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -203.24 |
T S2 APARTMENT | 22-FEB-12:45 | 0.00 | -3494.99 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 2869.83 | 0.00 | 349.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -184.69 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 29-JUL-16:30 | 0.00 | -209390.03 | 0.00 | 0.00 | 6680.31 | 11327.17 | 47212.47 | 124958.84 | 0.00 | 22504.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3292.94 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 12-NOV-09:45 | 1066.19 | 0.00 | 0.00 | 0.00 | 44.54 | 12.97 | 394.37 | 286.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1340.22 | -464.55 |
G NW APARTMENT | 16-MAR-11:55 | 1307.24 | 0.00 | 0.00 | 0.00 | 46.35 | 12.97 | 406.15 | 251.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1241.69 | -782.10 |
OFFICE | 04-FEB-07:00 | 782.29 | 0.00 | 0.00 | 0.00 | 0.00 | 469.18 | 194.24 | 0.00 | 0.00 | 0.00 | 245.18 | 0.00 | -1292.42 | 0.00 | -398.48 | 0.00 |
G NE APARTMENT | 24-JAN-14:30 | 1219.48 | 0.00 | 0.00 | 0.00 | 44.77 | 12.97 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -37.87 | 0.00 | -1251.67 | -370.28 |
G N1 APARTMENT | 16-MAR-11:55 | 1282.18 | 0.00 | 0.00 | 0.00 | 46.44 | 12.97 | 406.15 | 152.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1172.54 | -727.43 |
G N2 APARTMENT | 16-MAR-11:55 | 1309.51 | 0.00 | 0.00 | 0.00 | 46.35 | 12.97 | 406.15 | 150.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1172.72 | -752.47 |
G S1 APARTMENT | 12-NOV-09:45 | 937.78 | 0.00 | 0.00 | 0.00 | 44.04 | 12.97 | 394.37 | 216.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1259.63 | -345.77 |
G S2 APARTMENT | 12-NOV-09:45 | 904.39 | 0.00 | 0.00 | 0.00 | 43.94 | 12.97 | 394.37 | 214.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1261.85 | -308.68 |
F2 SW APARTMENT | 04-FEB-06:00 | 714.84 | 0.00 | 0.00 | 0.00 | 189.67 | 42.16 | 253.11 | 0.00 | 0.00 | 0.00 | 736.40 | 0.00 | -1336.26 | 0.00 | -599.90 | 0.00 |
F2 NW APARTMENT | 03-FEB-13:00 | 1511.62 | 0.00 | 0.00 | 0.00 | 44.34 | 12.97 | 406.15 | 225.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1801.21 | -399.77 |
F2 SE APARTMENT | 04-FEB-06:00 | 660.45 | 0.00 | 0.00 | 0.00 | 189.67 | 42.16 | 253.11 | 0.00 | 0.00 | 0.00 | 795.12 | 0.00 | -1340.60 | 0.00 | -599.90 | 0.00 |
F2 NE APARTMENT | 03-FEB-13:00 | 1493.58 | 0.00 | 0.00 | 0.00 | 44.15 | 12.97 | 406.15 | 123.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1799.69 | -280.27 |
F2 N1 APARTMENT | 03-FEB-13:00 | 1588.02 | 0.00 | 0.00 | 0.00 | 43.65 | 12.97 | 406.15 | 66.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1696.91 | -420.43 |
F2 N2 APARTMENT | 03-FEB-13:00 | 1583.84 | 0.00 | 0.00 | 0.00 | 43.64 | 12.97 | 406.15 | 66.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1696.90 | -415.83 |
F2 S1 APARTMENT | 18-MAR-05:20 | 119.70 | 0.00 | 0.00 | 0.00 | 175.83 | 45.40 | 317.85 | 0.00 | 0.00 | 0.00 | 479.20 | 0.00 | -273.38 | 0.00 | -864.60 | 0.00 |
F2 S2 APARTMENT | 18-MAR-05:20 | 121.04 | 0.00 | 0.00 | 0.00 | 176.00 | 45.40 | 317.85 | 0.00 | 0.00 | 0.00 | 475.39 | 0.00 | -273.84 | 0.00 | -861.84 | 0.00 |
F3 SW APARTMENT | 04-FEB-06:00 | 757.30 | 0.00 | 0.00 | 0.00 | 189.67 | 42.16 | 253.11 | 0.00 | 0.00 | 0.00 | 837.04 | 0.00 | -1368.30 | 0.00 | -710.98 | 0.00 |
F3 NW APARTMENT | 05-FEB-09:25 | 1520.21 | 0.00 | 0.00 | 0.00 | 47.10 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -49.30 | 0.00 | -1683.93 | -241.43 |
F3 SE APARTMENT | 04-FEB-06:00 | 792.54 | 0.00 | 0.00 | 0.00 | 189.67 | 42.16 | 253.11 | 0.00 | 0.00 | 0.00 | 798.47 | 0.00 | -1364.97 | 0.00 | -710.98 | 0.00 |
F3 NE APARTMENT | 03-FEB-13:00 | 1477.44 | 0.00 | 0.00 | 0.00 | 44.18 | 12.97 | 406.15 | 75.52 | 0.00 | 0.00 | 15.35 | 0.00 | 0.00 | 0.00 | -2031.61 | 0.00 |
F3 N1 APARTMENT | 03-FEB-13:00 | 1632.50 | 0.00 | 0.00 | 0.00 | 43.37 | 12.97 | 406.15 | 31.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1910.66 | -216.12 |
F3 N2 APARTMENT | 03-FEB-13:00 | 1629.82 | 0.00 | 0.00 | 0.00 | 43.35 | 12.97 | 406.15 | 31.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1910.65 | -213.06 |
F3 S1 APARTMENT | 18-MAR-05:20 | 117.20 | 0.00 | 0.00 | 0.00 | 175.64 | 45.40 | 317.85 | 0.00 | 0.00 | 0.00 | 623.75 | 0.00 | -283.83 | 0.00 | -996.01 | 0.00 |
F3 S2 APARTMENT | 18-MAR-05:20 | 116.68 | 0.00 | 0.00 | 0.00 | 175.61 | 45.40 | 317.85 | 0.00 | 0.00 | 0.00 | 625.59 | 0.00 | -284.01 | 0.00 | -997.11 | 0.00 |
F4 SW APARTMENT | 04-FEB-06:00 | 863.72 | 0.00 | 0.00 | 0.00 | 189.67 | 42.16 | 253.11 | 0.00 | 0.00 | 0.00 | 832.13 | 0.00 | -1385.28 | 0.00 | -795.50 | 0.00 |
F4 NW APARTMENT | 05-FEB-09:25 | 1624.55 | 0.00 | 0.00 | 0.00 | 47.25 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -62.07 | 0.00 | -1832.17 | -184.92 |
F4 SE APARTMENT | 04-FEB-06:00 | 920.68 | 0.00 | 0.00 | 0.00 | 189.67 | 42.16 | 253.11 | 0.00 | 0.00 | 0.00 | 769.92 | 0.00 | -1380.02 | 0.00 | -795.50 | 0.00 |
F4 NE APARTMENT | 03-FEB-13:15 | 1347.79 | 0.00 | 0.00 | 0.00 | 44.30 | 12.97 | 388.49 | 90.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1794.60 | -89.50 |
F4 N1 APARTMENT | 05-FEB-09:25 | 1649.10 | 0.00 | 0.00 | 0.00 | 46.67 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -61.65 | 0.00 | -1722.28 | -319.18 |
F4 N2 APARTMENT | 05-FEB-09:25 | 1649.46 | 0.00 | 0.00 | 0.00 | 46.66 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -62.08 | 0.00 | -1722.29 | -319.10 |
F4 S1 APARTMENT | 18-MAR-05:20 | 126.52 | 0.00 | 0.00 | 0.00 | 176.55 | 45.40 | 317.85 | 0.00 | 0.00 | 0.00 | 685.56 | 0.00 | -285.78 | 0.00 | -1066.10 | 0.00 |
F4 S2 APARTMENT | 18-MAR-05:20 | 126.33 | 0.00 | 0.00 | 0.00 | 176.58 | 45.40 | 317.85 | 0.00 | 0.00 | 0.00 | 684.52 | 0.00 | -285.65 | 0.00 | -1065.05 | 0.00 |
M SW APARTMENT | 04-FEB-06:00 | 959.70 | 0.00 | 0.00 | 0.00 | 189.67 | 42.16 | 253.11 | 0.00 | 0.00 | 0.00 | 818.63 | 0.00 | -1397.85 | 0.00 | -865.41 | 0.00 |
M NW APARTMENT | 05-FEB-09:25 | 1739.70 | 0.00 | 0.00 | 0.00 | 47.31 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -73.43 | 0.00 | -1959.30 | -161.63 |
M SE APARTMENT | 04-FEB-05:00 | 1021.77 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 821.39 | 0.00 | -1371.20 | 0.00 | -904.76 | 0.00 |
M NE APARTMENT | 05-FEB-09:25 | 1682.50 | 0.00 | 0.00 | 0.00 | 45.71 | 12.97 | 394.37 | 1156.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1967.74 | -1324.30 |
M N1 APARTMENT | 05-FEB-09:25 | 1744.09 | 0.00 | 0.00 | 0.00 | 46.72 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -70.16 | 0.00 | -1839.49 | -288.52 |
M N2 APARTMENT | 05-FEB-09:25 | 1745.59 | 0.00 | 0.00 | 0.00 | 46.71 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -70.61 | 0.00 | -1839.50 | -289.54 |
M S1 APARTMENT | 18-MAR-05:10 | 138.35 | 0.00 | 0.00 | 0.00 | 162.99 | 45.40 | 317.85 | 0.00 | 0.00 | 0.00 | 913.81 | 0.00 | -309.96 | 0.00 | -1268.45 | 0.00 |
M S2 APARTMENT | 04-FEB-06:00 | 211.04 | 0.00 | 0.00 | 0.00 | 191.66 | 42.16 | 253.11 | 0.00 | 0.00 | 0.00 | 671.99 | 0.00 | -848.85 | 0.00 | -521.11 | 0.00 |
F6 SW APARTMENT | 12-NOV-09:45 | 1172.16 | 0.00 | 0.00 | 0.00 | 43.62 | 12.97 | 394.37 | 58.06 | 0.00 | 0.00 | 489.55 | 0.00 | 0.00 | 0.00 | -2170.74 | 0.00 |
F6 NW APARTMENT | 05-FEB-09:20 | 1869.27 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -77.44 | 0.00 | -2071.86 | -174.73 |
F6 SE APARTMENT | 12-NOV-09:45 | 1175.27 | 0.00 | 0.00 | 0.00 | 43.61 | 12.97 | 394.37 | 159.27 | 0.00 | 0.00 | 381.42 | 0.00 | 0.00 | 0.00 | -2166.92 | 0.00 |
F6 NE APARTMENT | 05-FEB-09:25 | 1859.29 | 0.00 | 0.00 | 0.00 | 46.07 | 12.97 | 394.37 | 1133.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2075.87 | -1370.75 |
F6 N1 APARTMENT | 05-FEB-09:25 | 1768.21 | 0.00 | 0.00 | 0.00 | 47.00 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -72.25 | 0.00 | -1943.07 | -207.24 |
F6 N2 APARTMENT | 05-FEB-09:25 | 1769.26 | 0.00 | 0.00 | 0.00 | 46.99 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -72.70 | 0.00 | -1943.08 | -207.81 |
F6 S1 APARTMENT | 12-NOV-09:45 | 369.82 | 0.00 | 0.00 | 0.00 | 41.97 | 12.97 | 394.37 | 75.49 | 0.00 | 0.00 | 1111.16 | 0.00 | 0.00 | 0.00 | -2005.79 | 0.00 |
F6 S2 APARTMENT | 12-NOV-09:45 | 364.72 | 0.00 | 0.00 | 0.00 | 41.97 | 12.97 | 394.37 | 75.40 | 0.00 | 0.00 | 1116.43 | 0.00 | 0.00 | 0.00 | -2005.86 | 0.00 |
F7 SW APARTMENT | 12-NOV-10:00 | 1236.08 | 0.00 | 0.00 | 0.00 | 43.72 | 12.97 | 394.37 | 54.20 | 0.00 | 0.00 | 401.42 | 0.00 | 0.00 | 0.00 | -2142.77 | 0.00 |
F7 NW APARTMENT | 05-FEB-09:20 | 1997.69 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -82.90 | 0.00 | -2174.39 | -195.17 |
F7 SE APARTMENT | 04-FEB-05:00 | 1264.04 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 709.18 | 0.00 | -1381.80 | 0.00 | -1024.22 | 0.00 |
F7 NE APARTMENT | 03-FEB-15:10 | 1956.64 | 0.00 | 0.00 | 0.00 | 46.25 | 22.70 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -98.79 | 0.00 | -2132.10 | -194.95 |
F7 N1 APARTMENT | 05-FEB-09:25 | 1818.10 | 0.00 | 0.00 | 0.00 | 47.16 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -75.24 | 0.00 | -2037.43 | -159.93 |
F7 N2 APARTMENT | 05-FEB-09:25 | 1811.84 | 0.00 | 0.00 | 0.00 | 47.16 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -75.63 | 0.00 | -2037.42 | -153.29 |
F7 S1 APARTMENT | 05-FEB-09:30 | 531.79 | 0.00 | 0.00 | 0.00 | 43.95 | 12.97 | 394.37 | 1288.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1530.49 | -740.66 |
F7 S2 APARTMENT | 05-FEB-09:30 | 534.47 | 0.00 | 0.00 | 0.00 | 43.94 | 12.97 | 394.37 | 1287.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1530.58 | -742.88 |
F8 SW APARTMENT | 12-NOV-10:00 | 1439.35 | 0.00 | 0.00 | 0.00 | 44.01 | 12.97 | 394.37 | 50.45 | 0.00 | 0.00 | 284.99 | 0.00 | 0.00 | 0.00 | -2226.16 | 0.00 |
F8 NW APARTMENT | 05-FEB-09:20 | 2114.62 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -88.00 | 0.00 | -2268.99 | -212.39 |
F8 SE APARTMENT | 12-NOV-10:00 | 1397.46 | 0.00 | 0.00 | 0.00 | 44.02 | 12.97 | 394.37 | 138.46 | 0.00 | 0.00 | 237.02 | 0.00 | 0.00 | 0.00 | -2224.30 | 0.00 |
F8 NE APARTMENT | 03-FEB-15:10 | 1992.83 | 0.00 | 0.00 | 0.00 | 46.41 | 22.70 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -103.24 | 0.00 | -2220.04 | -138.92 |
F8 N1 APARTMENT | 05-FEB-09:25 | 1864.02 | 0.00 | 0.00 | 0.00 | 47.30 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -77.81 | 0.00 | -2124.59 | -116.26 |
F8 N2 APARTMENT | 05-FEB-09:25 | 1861.76 | 0.00 | 0.00 | 0.00 | 47.29 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -78.23 | 0.00 | -2124.60 | -113.57 |
F8 S1 APARTMENT | 05-FEB-09:30 | 869.30 | 0.00 | 0.00 | 0.00 | 44.26 | 12.97 | 394.37 | 1279.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1573.53 | -1027.02 |
F8 S2 APARTMENT | 05-FEB-09:30 | 872.57 | 0.00 | 0.00 | 0.00 | 44.25 | 12.97 | 394.37 | 1279.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1573.60 | -1029.84 |
F9 SW APARTMENT | 12-NOV-10:00 | 1443.00 | 0.00 | 0.00 | 0.00 | 44.55 | 12.97 | 394.37 | 59.32 | 0.00 | 0.00 | 354.62 | 0.00 | 0.00 | 0.00 | -2308.84 | 0.00 |
F9 NW APARTMENT | 05-FEB-09:20 | 2256.31 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -89.14 | 0.00 | -2357.32 | -264.62 |
F9 SE APARTMENT | 04-FEB-05:00 | 1476.20 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 598.37 | 0.00 | -1385.36 | 0.00 | -1122.01 | 0.00 |
F9 NE APARTMENT | 03-FEB-13:10 | 2148.69 | 0.00 | 0.00 | 0.00 | 46.04 | 12.97 | 388.49 | 61.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2272.70 | -384.69 |
F9 N1 APARTMENT | 03-FEB-15:10 | 2095.75 | 0.00 | 0.00 | 0.00 | 45.92 | 22.70 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -92.83 | 0.00 | -2128.68 | -343.12 |
F9 N2 APARTMENT | 03-FEB-15:10 | 2104.01 | 0.00 | 0.00 | 0.00 | 45.93 | 22.70 | 400.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -92.68 | 0.00 | -2128.43 | -351.78 |
F9 S1 APARTMENT | 12-NOV-10:00 | 1246.84 | 0.00 | 0.00 | 0.00 | 42.85 | 12.97 | 394.37 | 68.92 | 0.00 | 0.00 | 344.06 | 0.00 | 0.00 | 0.00 | -2110.02 | 0.00 |
F9 S2 APARTMENT | 12-NOV-10:00 | 1244.05 | 0.00 | 0.00 | 0.00 | 42.85 | 12.97 | 394.37 | 68.86 | 0.00 | 0.00 | 346.87 | 0.00 | 0.00 | 0.00 | -2109.98 | 0.00 |
T SW APARTMENT | 12-NOV-09:55 | 2221.03 | 0.00 | 0.00 | 0.00 | 46.16 | 12.97 | 394.37 | 111.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2389.43 | -396.66 |
T NW APARTMENT | 05-FEB-09:20 | 2358.04 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -83.39 | 0.00 | -2440.53 | -288.89 |
T SE APARTMENT | 12-NOV-09:55 | 2173.44 | 0.00 | 0.00 | 0.00 | 46.19 | 12.97 | 394.37 | 195.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2387.81 | -434.82 |
T NE APARTMENT | 04-FEB-05:00 | 2274.65 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1350.43 | 0.00 | -1165.41 | -191.61 |
T N1 APARTMENT | 12-NOV-09:55 | 2294.34 | 0.00 | 0.00 | 0.00 | 45.73 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -25.47 | 0.00 | -2173.36 | -548.60 |
T N2 APARTMENT | 12-NOV-09:55 | 2286.54 | 0.00 | 0.00 | 0.00 | 45.74 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -25.42 | 0.00 | -2173.25 | -540.96 |
T S1 APARTMENT | 19-MAR-13:30 | 1647.26 | 0.00 | 0.00 | 0.00 | 43.53 | 12.97 | 382.60 | 76.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2146.96 | -15.74 |
T S2 APARTMENT | 19-MAR-13:30 | 1647.77 | 0.00 | 0.00 | 0.00 | 43.53 | 12.97 | 382.60 | 76.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2146.98 | -16.17 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 05-FEB-09:30 | 77007.25 | 0.00 | 0.00 | 0.00 | 3580.91 | 7228.24 | 31714.40 | 79290.67 | 0.00 | 0.00 | 0.00 | 0.00 | -1811.33 | 0.00 | -137827.48 | -59182.66 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2015-09-09 19:12:00
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2015-09-09 19:12:00
Sec1.1A-General InformationData | |
Weather File | Miami Intl Ap FL USA TMY3 WMO#=722020 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 7836.48 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.50 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F2 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F3 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F4 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F6 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F7 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F8 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F9 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 7836.48 | 7059.89 | 776.58 |
Data | |
Number of hours heating loads not met | 1.50 |
Number of hours cooling loads not met | 980.25 |
Number of hours not met | 981.75 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 296.56 | 13120.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 163.14 | 10364.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 2.28 | 0.00 | 2.69 | 73437.26 | 0.00 | 0.00 |
Space Cooling | 1430.98 | 80892.51 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 79.68 | 2580.93 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 73.72 | 3797.79 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 650.69 | 20633.29 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 0.00 | 0.00 | 811.17 | 69627.49 | 0.00 | 0.00 |
Receptacle Equipment | 1137.32 | 57042.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 3870.55 | 813.86 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 1137.32 | 3870.55 |
Natural Gas | 0.00 | 813.86 |
Additional | 0.00 | 0.00 |
Total | 1137.32 | 4684.41 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 37.84 |
Space Heating | 0.29 |
Space Cooling | 182.61 |
Fans-Interior | 83.03 |
Service Water Heating | 0.00 |
Receptacle Equipment | 145.13 |
Miscellaneous | 45.01 |
Subtotal | 493.91 |
Natural Gas [MJ/m2] | |
Space Heating | 0.34 |
Service Water Heating | 103.51 |
Miscellaneous | -0.00 |
Subtotal | 103.86 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 6.33 |
Space Heating | 0.11 |
Space Cooling | 30.55 |
Fans-Interior | 13.89 |
Service Water Heating | 17.32 |
Receptacle Equipment | 24.28 |
Miscellaneous | 7.53 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:12:00
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.241276 |
G NW APARTMENT DIRECT AIR | 0.255539 |
OFFICE DIRECT AIR | 0.333019 |
G NE APARTMENT DIRECT AIR | 0.202794 |
G N1 APARTMENT DIRECT AIR | 0.133702 |
G N2 APARTMENT DIRECT AIR | 0.132367 |
G S1 APARTMENT DIRECT AIR | 0.114106 |
G S2 APARTMENT DIRECT AIR | 0.119052 |
F2 SW APARTMENT DIRECT AIR | 0.291236 |
F2 NW APARTMENT DIRECT AIR | 0.306607 |
F2 SE APARTMENT DIRECT AIR | 0.261354 |
F2 NE APARTMENT DIRECT AIR | 0.245436 |
F2 N1 APARTMENT DIRECT AIR | 0.167209 |
F2 N2 APARTMENT DIRECT AIR | 0.166145 |
F2 S1 APARTMENT DIRECT AIR | 0.146383 |
F2 S2 APARTMENT DIRECT AIR | 0.146915 |
F3 SW APARTMENT DIRECT AIR | 0.292255 |
F3 NW APARTMENT DIRECT AIR | 0.307680 |
F3 SE APARTMENT DIRECT AIR | 0.243375 |
F3 NE APARTMENT DIRECT AIR | 0.246649 |
F3 N1 APARTMENT DIRECT AIR | 0.169609 |
F3 N2 APARTMENT DIRECT AIR | 0.168548 |
F3 S1 APARTMENT DIRECT AIR | 0.148924 |
F3 S2 APARTMENT DIRECT AIR | 0.148815 |
F4 SW APARTMENT DIRECT AIR | 0.293716 |
F4 NW APARTMENT DIRECT AIR | 0.308980 |
F4 SE APARTMENT DIRECT AIR | 0.242248 |
F4 NE APARTMENT DIRECT AIR | 0.247145 |
F4 N1 APARTMENT DIRECT AIR | 0.171269 |
F4 N2 APARTMENT DIRECT AIR | 0.170209 |
F4 S1 APARTMENT DIRECT AIR | 0.150837 |
F4 S2 APARTMENT DIRECT AIR | 0.150556 |
M SW APARTMENT DIRECT AIR | 0.296945 |
M NW APARTMENT DIRECT AIR | 0.312163 |
M SE APARTMENT DIRECT AIR | 0.244615 |
M NE APARTMENT DIRECT AIR | 0.249668 |
M N1 APARTMENT DIRECT AIR | 0.174602 |
M N2 APARTMENT DIRECT AIR | 0.173544 |
M S1 APARTMENT DIRECT AIR | 0.154268 |
M S2 APARTMENT DIRECT AIR | 0.153947 |
F6 SW APARTMENT DIRECT AIR | 0.294740 |
F6 NW APARTMENT DIRECT AIR | 0.309751 |
F6 SE APARTMENT DIRECT AIR | 0.241890 |
F6 NE APARTMENT DIRECT AIR | 0.246781 |
F6 N1 APARTMENT DIRECT AIR | 0.172500 |
F6 N2 APARTMENT DIRECT AIR | 0.171447 |
F6 S1 APARTMENT DIRECT AIR | 0.152451 |
F6 S2 APARTMENT DIRECT AIR | 0.152098 |
F7 SW APARTMENT DIRECT AIR | 0.294444 |
F7 NW APARTMENT DIRECT AIR | 0.309371 |
F7 SE APARTMENT DIRECT AIR | 0.241131 |
F7 NE APARTMENT DIRECT AIR | 0.245956 |
F7 N1 APARTMENT DIRECT AIR | 0.172309 |
F7 N2 APARTMENT DIRECT AIR | 0.171273 |
F7 S1 APARTMENT DIRECT AIR | 0.152403 |
F7 S2 APARTMENT DIRECT AIR | 0.152032 |
F8 SW APARTMENT DIRECT AIR | 0.295390 |
F8 NW APARTMENT DIRECT AIR | 0.310252 |
F8 SE APARTMENT DIRECT AIR | 0.241599 |
F8 NE APARTMENT DIRECT AIR | 0.246352 |
F8 N1 APARTMENT DIRECT AIR | 0.173363 |
F8 N2 APARTMENT DIRECT AIR | 0.172335 |
F8 S1 APARTMENT DIRECT AIR | 0.153570 |
F8 S2 APARTMENT DIRECT AIR | 0.153110 |
F9 SW APARTMENT DIRECT AIR | 0.305011 |
F9 NW APARTMENT DIRECT AIR | 0.320069 |
F9 SE APARTMENT DIRECT AIR | 0.246484 |
F9 NE APARTMENT DIRECT AIR | 0.250954 |
F9 N1 APARTMENT DIRECT AIR | 0.182223 |
F9 N2 APARTMENT DIRECT AIR | 0.181170 |
F9 S1 APARTMENT DIRECT AIR | 0.162442 |
F9 S2 APARTMENT DIRECT AIR | 0.161433 |
T SW APARTMENT DIRECT AIR | 0.367908 |
T NW APARTMENT DIRECT AIR | 0.378428 |
T SE APARTMENT DIRECT AIR | 0.304103 |
T NE APARTMENT DIRECT AIR | 0.305700 |
T N1 APARTMENT DIRECT AIR | 0.223964 |
T N2 APARTMENT DIRECT AIR | 0.221673 |
T S1 APARTMENT DIRECT AIR | 0.226153 |
T S2 APARTMENT DIRECT AIR | 0.226488 |
Maximum Flow Rate [m3/s] | |
AIRLOOP G SW MAIN BRANCH | 0.241276 |
AIRLOOP G NW MAIN BRANCH | 0.255539 |
AIRLOOP OFFICE MAIN BRANCH | 0.333019 |
AIRLOOP G NE MAIN BRANCH | 0.202794 |
AIRLOOP G N1 MAIN BRANCH | 0.133702 |
AIRLOOP G N2 MAIN BRANCH | 0.132367 |
AIRLOOP G S1 MAIN BRANCH | 0.114106 |
AIRLOOP G S2 MAIN BRANCH | 0.119052 |
AIRLOOP F2 SW MAIN BRANCH | 0.291236 |
AIRLOOP F2 NW MAIN BRANCH | 0.306607 |
AIRLOOP F2 SE MAIN BRANCH | 0.261354 |
AIRLOOP F2 NE MAIN BRANCH | 0.245436 |
AIRLOOP F2 N1 MAIN BRANCH | 0.167209 |
AIRLOOP F2 N2 MAIN BRANCH | 0.166145 |
AIRLOOP F2 S1 MAIN BRANCH | 0.146383 |
AIRLOOP F2 S2 MAIN BRANCH | 0.146915 |
AIRLOOP F3 SW MAIN BRANCH | 0.292255 |
AIRLOOP F3 NW MAIN BRANCH | 0.307680 |
AIRLOOP F3 SE MAIN BRANCH | 0.243375 |
AIRLOOP F3 NE MAIN BRANCH | 0.246649 |
AIRLOOP F3 N1 MAIN BRANCH | 0.169609 |
AIRLOOP F3 N2 MAIN BRANCH | 0.168548 |
AIRLOOP F3 S1 MAIN BRANCH | 0.148924 |
AIRLOOP F3 S2 MAIN BRANCH | 0.148815 |
AIRLOOP F4 SW MAIN BRANCH | 0.293716 |
AIRLOOP F4 NW MAIN BRANCH | 0.308980 |
AIRLOOP F4 SE MAIN BRANCH | 0.242248 |
AIRLOOP F4 NE MAIN BRANCH | 0.247145 |
AIRLOOP F4 N1 MAIN BRANCH | 0.171269 |
AIRLOOP F4 N2 MAIN BRANCH | 0.170209 |
AIRLOOP F4 S1 MAIN BRANCH | 0.150837 |
AIRLOOP F4 S2 MAIN BRANCH | 0.150556 |
AIRLOOP M SW MAIN BRANCH | 0.296945 |
AIRLOOP M NW MAIN BRANCH | 0.312163 |
AIRLOOP M SE MAIN BRANCH | 0.244615 |
AIRLOOP M NE MAIN BRANCH | 0.249668 |
AIRLOOP M N1 MAIN BRANCH | 0.174602 |
AIRLOOP M N2 MAIN BRANCH | 0.173544 |
AIRLOOP M S1 MAIN BRANCH | 0.154268 |
AIRLOOP M S2 MAIN BRANCH | 0.153947 |
AIRLOOP F6 SW MAIN BRANCH | 0.294740 |
AIRLOOP F6 NW MAIN BRANCH | 0.309751 |
AIRLOOP F6 SE MAIN BRANCH | 0.241890 |
AIRLOOP F6 NE MAIN BRANCH | 0.246781 |
AIRLOOP F6 N1 MAIN BRANCH | 0.172500 |
AIRLOOP F6 N2 MAIN BRANCH | 0.171447 |
AIRLOOP F6 S1 MAIN BRANCH | 0.152451 |
AIRLOOP F6 S2 MAIN BRANCH | 0.152098 |
AIRLOOP F7 SW MAIN BRANCH | 0.294444 |
AIRLOOP F7 NW MAIN BRANCH | 0.309371 |
AIRLOOP F7 SE MAIN BRANCH | 0.241131 |
AIRLOOP F7 NE MAIN BRANCH | 0.245956 |
AIRLOOP F7 N1 MAIN BRANCH | 0.172309 |
AIRLOOP F7 N2 MAIN BRANCH | 0.171273 |
AIRLOOP F7 S1 MAIN BRANCH | 0.152403 |
AIRLOOP F7 S2 MAIN BRANCH | 0.152032 |
AIRLOOP F8 SW MAIN BRANCH | 0.295390 |
AIRLOOP F8 NW MAIN BRANCH | 0.310252 |
AIRLOOP F8 SE MAIN BRANCH | 0.241599 |
AIRLOOP F8 NE MAIN BRANCH | 0.246352 |
AIRLOOP F8 N1 MAIN BRANCH | 0.173363 |
AIRLOOP F8 N2 MAIN BRANCH | 0.172335 |
AIRLOOP F8 S1 MAIN BRANCH | 0.153570 |
AIRLOOP F8 S2 MAIN BRANCH | 0.153110 |
AIRLOOP F9 SW MAIN BRANCH | 0.305011 |
AIRLOOP F9 NW MAIN BRANCH | 0.320069 |
AIRLOOP F9 SE MAIN BRANCH | 0.246484 |
AIRLOOP F9 NE MAIN BRANCH | 0.250954 |
AIRLOOP F9 N1 MAIN BRANCH | 0.182223 |
AIRLOOP F9 N2 MAIN BRANCH | 0.181170 |
AIRLOOP F9 S1 MAIN BRANCH | 0.162442 |
AIRLOOP F9 S2 MAIN BRANCH | 0.161433 |
AIRLOOP T SW MAIN BRANCH | 0.367908 |
AIRLOOP T NW MAIN BRANCH | 0.378428 |
AIRLOOP T SE MAIN BRANCH | 0.304103 |
AIRLOOP T NE MAIN BRANCH | 0.305700 |
AIRLOOP T N1 MAIN BRANCH | 0.223964 |
AIRLOOP T N2 MAIN BRANCH | 0.221673 |
AIRLOOP T S1 MAIN BRANCH | 0.226153 |
AIRLOOP T S2 MAIN BRANCH | 0.226488 |
Design Supply Air Flow Rate [m3/s] | |
AIRLOOP G SW | 0.241276 |
AIRLOOP G NW | 0.255539 |
AIRLOOP OFFICE | 0.333019 |
AIRLOOP G NE | 0.202794 |
AIRLOOP G N1 | 0.133702 |
AIRLOOP G N2 | 0.132367 |
AIRLOOP G S1 | 0.114106 |
AIRLOOP G S2 | 0.119052 |
AIRLOOP F2 SW | 0.291236 |
AIRLOOP F2 NW | 0.306607 |
AIRLOOP F2 SE | 0.261354 |
AIRLOOP F2 NE | 0.245436 |
AIRLOOP F2 N1 | 0.167209 |
AIRLOOP F2 N2 | 0.166145 |
AIRLOOP F2 S1 | 0.146383 |
AIRLOOP F2 S2 | 0.146915 |
AIRLOOP F3 SW | 0.292255 |
AIRLOOP F3 NW | 0.307680 |
AIRLOOP F3 SE | 0.243375 |
AIRLOOP F3 NE | 0.246649 |
AIRLOOP F3 N1 | 0.169609 |
AIRLOOP F3 N2 | 0.168548 |
AIRLOOP F3 S1 | 0.148924 |
AIRLOOP F3 S2 | 0.148815 |
AIRLOOP F4 SW | 0.293716 |
AIRLOOP F4 NW | 0.308980 |
AIRLOOP F4 SE | 0.242248 |
AIRLOOP F4 NE | 0.247145 |
AIRLOOP F4 N1 | 0.171269 |
AIRLOOP F4 N2 | 0.170209 |
AIRLOOP F4 S1 | 0.150837 |
AIRLOOP F4 S2 | 0.150556 |
AIRLOOP M SW | 0.296945 |
AIRLOOP M NW | 0.312163 |
AIRLOOP M SE | 0.244615 |
AIRLOOP M NE | 0.249668 |
AIRLOOP M N1 | 0.174602 |
AIRLOOP M N2 | 0.173544 |
AIRLOOP M S1 | 0.154268 |
AIRLOOP M S2 | 0.153947 |
AIRLOOP F6 SW | 0.294740 |
AIRLOOP F6 NW | 0.309751 |
AIRLOOP F6 SE | 0.241890 |
AIRLOOP F6 NE | 0.246781 |
AIRLOOP F6 N1 | 0.172500 |
AIRLOOP F6 N2 | 0.171447 |
AIRLOOP F6 S1 | 0.152451 |
AIRLOOP F6 S2 | 0.152098 |
AIRLOOP F7 SW | 0.294444 |
AIRLOOP F7 NW | 0.309371 |
AIRLOOP F7 SE | 0.241131 |
AIRLOOP F7 NE | 0.245956 |
AIRLOOP F7 N1 | 0.172309 |
AIRLOOP F7 N2 | 0.171273 |
AIRLOOP F7 S1 | 0.152403 |
AIRLOOP F7 S2 | 0.152032 |
AIRLOOP F8 SW | 0.295390 |
AIRLOOP F8 NW | 0.310252 |
AIRLOOP F8 SE | 0.241599 |
AIRLOOP F8 NE | 0.246352 |
AIRLOOP F8 N1 | 0.173363 |
AIRLOOP F8 N2 | 0.172335 |
AIRLOOP F8 S1 | 0.153570 |
AIRLOOP F8 S2 | 0.153110 |
AIRLOOP F9 SW | 0.305011 |
AIRLOOP F9 NW | 0.320069 |
AIRLOOP F9 SE | 0.246484 |
AIRLOOP F9 NE | 0.250954 |
AIRLOOP F9 N1 | 0.182223 |
AIRLOOP F9 N2 | 0.181170 |
AIRLOOP F9 S1 | 0.162442 |
AIRLOOP F9 S2 | 0.161433 |
AIRLOOP T SW | 0.367908 |
AIRLOOP T NW | 0.378428 |
AIRLOOP T SE | 0.304103 |
AIRLOOP T NE | 0.305700 |
AIRLOOP T N1 | 0.223964 |
AIRLOOP T N2 | 0.221673 |
AIRLOOP T S1 | 0.226153 |
AIRLOOP T S2 | 0.226488 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
AIRLOOP G SW OA CONTROLLER | 0.241276 | 0.025952 |
AIRLOOP G NW OA CONTROLLER | 0.255539 | 0.025952 |
AIRLOOP OFFICE OA CONTROLLER | 0.333019 | 0.038103 |
AIRLOOP G NE OA CONTROLLER | 0.202794 | 0.025952 |
AIRLOOP G N1 OA CONTROLLER | 0.133702 | 0.025952 |
AIRLOOP G N2 OA CONTROLLER | 0.132367 | 0.025952 |
AIRLOOP G S1 OA CONTROLLER | 0.114106 | 0.025952 |
AIRLOOP G S2 OA CONTROLLER | 0.119052 | 0.025952 |
AIRLOOP F2 SW OA CONTROLLER | 0.291236 | 0.025952 |
AIRLOOP F2 NW OA CONTROLLER | 0.306607 | 0.025952 |
AIRLOOP F2 SE OA CONTROLLER | 0.261354 | 0.025952 |
AIRLOOP F2 NE OA CONTROLLER | 0.245436 | 0.025952 |
AIRLOOP F2 N1 OA CONTROLLER | 0.167209 | 0.025952 |
AIRLOOP F2 N2 OA CONTROLLER | 0.166145 | 0.025952 |
AIRLOOP F2 S1 OA CONTROLLER | 0.146383 | 0.025952 |
AIRLOOP F2 S2 OA CONTROLLER | 0.146915 | 0.025952 |
AIRLOOP F3 SW OA CONTROLLER | 0.292255 | 0.025952 |
AIRLOOP F3 NW OA CONTROLLER | 0.307680 | 0.025952 |
AIRLOOP F3 SE OA CONTROLLER | 0.243375 | 0.025952 |
AIRLOOP F3 NE OA CONTROLLER | 0.246649 | 0.025952 |
AIRLOOP F3 N1 OA CONTROLLER | 0.169609 | 0.025952 |
AIRLOOP F3 N2 OA CONTROLLER | 0.168548 | 0.025952 |
AIRLOOP F3 S1 OA CONTROLLER | 0.148924 | 0.025952 |
AIRLOOP F3 S2 OA CONTROLLER | 0.148815 | 0.025952 |
AIRLOOP F4 SW OA CONTROLLER | 0.293716 | 0.025952 |
AIRLOOP F4 NW OA CONTROLLER | 0.308980 | 0.025952 |
AIRLOOP F4 SE OA CONTROLLER | 0.242248 | 0.025952 |
AIRLOOP F4 NE OA CONTROLLER | 0.247145 | 0.025952 |
AIRLOOP F4 N1 OA CONTROLLER | 0.171269 | 0.025952 |
AIRLOOP F4 N2 OA CONTROLLER | 0.170209 | 0.025952 |
AIRLOOP F4 S1 OA CONTROLLER | 0.150837 | 0.025952 |
AIRLOOP F4 S2 OA CONTROLLER | 0.150556 | 0.025952 |
AIRLOOP M SW OA CONTROLLER | 0.296945 | 0.025952 |
AIRLOOP M NW OA CONTROLLER | 0.312163 | 0.025952 |
AIRLOOP M SE OA CONTROLLER | 0.244615 | 0.025952 |
AIRLOOP M NE OA CONTROLLER | 0.249668 | 0.025952 |
AIRLOOP M N1 OA CONTROLLER | 0.174602 | 0.025952 |
AIRLOOP M N2 OA CONTROLLER | 0.173544 | 0.025952 |
AIRLOOP M S1 OA CONTROLLER | 0.154268 | 0.025952 |
AIRLOOP M S2 OA CONTROLLER | 0.153947 | 0.025952 |
AIRLOOP F6 SW OA CONTROLLER | 0.294740 | 0.025952 |
AIRLOOP F6 NW OA CONTROLLER | 0.309751 | 0.025952 |
AIRLOOP F6 SE OA CONTROLLER | 0.241890 | 0.025952 |
AIRLOOP F6 NE OA CONTROLLER | 0.246781 | 0.025952 |
AIRLOOP F6 N1 OA CONTROLLER | 0.172500 | 0.025952 |
AIRLOOP F6 N2 OA CONTROLLER | 0.171447 | 0.025952 |
AIRLOOP F6 S1 OA CONTROLLER | 0.152451 | 0.025952 |
AIRLOOP F6 S2 OA CONTROLLER | 0.152098 | 0.025952 |
AIRLOOP F7 SW OA CONTROLLER | 0.294444 | 0.025952 |
AIRLOOP F7 NW OA CONTROLLER | 0.309371 | 0.025952 |
AIRLOOP F7 SE OA CONTROLLER | 0.241131 | 0.025952 |
AIRLOOP F7 NE OA CONTROLLER | 0.245956 | 0.025952 |
AIRLOOP F7 N1 OA CONTROLLER | 0.172309 | 0.025952 |
AIRLOOP F7 N2 OA CONTROLLER | 0.171273 | 0.025952 |
AIRLOOP F7 S1 OA CONTROLLER | 0.152403 | 0.025952 |
AIRLOOP F7 S2 OA CONTROLLER | 0.152032 | 0.025952 |
AIRLOOP F8 SW OA CONTROLLER | 0.295390 | 0.025952 |
AIRLOOP F8 NW OA CONTROLLER | 0.310252 | 0.025952 |
AIRLOOP F8 SE OA CONTROLLER | 0.241599 | 0.025952 |
AIRLOOP F8 NE OA CONTROLLER | 0.246352 | 0.025952 |
AIRLOOP F8 N1 OA CONTROLLER | 0.173363 | 0.025952 |
AIRLOOP F8 N2 OA CONTROLLER | 0.172335 | 0.025952 |
AIRLOOP F8 S1 OA CONTROLLER | 0.153570 | 0.025952 |
AIRLOOP F8 S2 OA CONTROLLER | 0.153110 | 0.025952 |
AIRLOOP F9 SW OA CONTROLLER | 0.305011 | 0.025952 |
AIRLOOP F9 NW OA CONTROLLER | 0.320069 | 0.025952 |
AIRLOOP F9 SE OA CONTROLLER | 0.246484 | 0.025952 |
AIRLOOP F9 NE OA CONTROLLER | 0.250954 | 0.025952 |
AIRLOOP F9 N1 OA CONTROLLER | 0.182223 | 0.025952 |
AIRLOOP F9 N2 OA CONTROLLER | 0.181170 | 0.025952 |
AIRLOOP F9 S1 OA CONTROLLER | 0.162442 | 0.025952 |
AIRLOOP F9 S2 OA CONTROLLER | 0.161433 | 0.025952 |
AIRLOOP T SW OA CONTROLLER | 0.367908 | 0.025952 |
AIRLOOP T NW OA CONTROLLER | 0.378428 | 0.025952 |
AIRLOOP T SE OA CONTROLLER | 0.304103 | 0.025952 |
AIRLOOP T NE OA CONTROLLER | 0.305700 | 0.025952 |
AIRLOOP T N1 OA CONTROLLER | 0.223964 | 0.025952 |
AIRLOOP T N2 OA CONTROLLER | 0.221673 | 0.025952 |
AIRLOOP T S1 OA CONTROLLER | 0.226153 | 0.025952 |
AIRLOOP T S2 OA CONTROLLER | 0.226488 | 0.025952 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity [W] | Rated Sensible Cooling Capacity [W] | Rated Water Flow Rate [m3/s] | |
HEAT PUMP COOLING MODE AIRLOOP G SW | 0.241276 | 4657.48 | 3073.42 | 0.000102 |
HEAT PUMP COOLING MODE AIRLOOP G NW | 0.255539 | 4863.02 | 3228.39 | 0.000106 |
HEAT PUMP COOLING MODE AIRLOOP OFFICE | 0.333019 | 6318.01 | 4202.77 | 0.000138 |
HEAT PUMP COOLING MODE AIRLOOP G NE | 0.202794 | 4067.74 | 2636.58 | 0.000089 |
HEAT PUMP COOLING MODE AIRLOOP G N1 | 0.133702 | 2953.10 | 1845.21 | 0.000065 |
HEAT PUMP COOLING MODE AIRLOOP G N2 | 0.132367 | 2932.89 | 1830.49 | 0.000064 |
HEAT PUMP COOLING MODE AIRLOOP G S1 | 0.114106 | 2652.61 | 1628.90 | 0.000058 |
HEAT PUMP COOLING MODE AIRLOOP G S2 | 0.119052 | 2760.08 | 1697.86 | 0.000060 |
HEAT PUMP COOLING MODE AIRLOOP F2 SW | 0.291236 | 5520.21 | 3668.16 | 0.000121 |
HEAT PUMP COOLING MODE AIRLOOP F2 NW | 0.306607 | 5743.42 | 3836.61 | 0.000125 |
HEAT PUMP COOLING MODE AIRLOOP F2 SE | 0.261354 | 5069.75 | 3332.45 | 0.000111 |
HEAT PUMP COOLING MODE AIRLOOP F2 NE | 0.245436 | 4824.96 | 3151.30 | 0.000105 |
HEAT PUMP COOLING MODE AIRLOOP F2 N1 | 0.167209 | 3525.90 | 2240.36 | 0.000077 |
HEAT PUMP COOLING MODE AIRLOOP F2 N2 | 0.166145 | 3509.93 | 2228.61 | 0.000077 |
HEAT PUMP COOLING MODE AIRLOOP F2 S1 | 0.146383 | 3211.16 | 2010.90 | 0.000070 |
HEAT PUMP COOLING MODE AIRLOOP F2 S2 | 0.146915 | 3250.39 | 2031.94 | 0.000071 |
HEAT PUMP COOLING MODE AIRLOOP F3 SW | 0.292255 | 5618.89 | 3708.27 | 0.000123 |
HEAT PUMP COOLING MODE AIRLOOP F3 NW | 0.307680 | 5843.03 | 3876.39 | 0.000128 |
HEAT PUMP COOLING MODE AIRLOOP F3 SE | 0.243375 | 4884.90 | 3162.20 | 0.000107 |
HEAT PUMP COOLING MODE AIRLOOP F3 NE | 0.246649 | 4921.46 | 3192.19 | 0.000108 |
HEAT PUMP COOLING MODE AIRLOOP F3 N1 | 0.169609 | 3606.30 | 2283.30 | 0.000079 |
HEAT PUMP COOLING MODE AIRLOOP F3 N2 | 0.168548 | 3590.28 | 2271.58 | 0.000078 |
HEAT PUMP COOLING MODE AIRLOOP F3 S1 | 0.148924 | 3291.30 | 2054.94 | 0.000072 |
HEAT PUMP COOLING MODE AIRLOOP F3 S2 | 0.148815 | 3320.73 | 2068.83 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F4 SW | 0.293716 | 5701.31 | 3745.16 | 0.000125 |
HEAT PUMP COOLING MODE AIRLOOP F4 NW | 0.308980 | 5924.10 | 3911.65 | 0.000129 |
HEAT PUMP COOLING MODE AIRLOOP F4 SE | 0.242248 | 4925.51 | 3170.25 | 0.000108 |
HEAT PUMP COOLING MODE AIRLOOP F4 NE | 0.247145 | 4991.07 | 3220.72 | 0.000109 |
HEAT PUMP COOLING MODE AIRLOOP F4 N1 | 0.171269 | 3664.22 | 2313.94 | 0.000080 |
HEAT PUMP COOLING MODE AIRLOOP F4 N2 | 0.170209 | 3648.15 | 2302.23 | 0.000080 |
HEAT PUMP COOLING MODE AIRLOOP F4 S1 | 0.150837 | 3351.33 | 2088.06 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F4 S2 | 0.150556 | 3378.06 | 2100.00 | 0.000074 |
HEAT PUMP COOLING MODE AIRLOOP M SW | 0.296945 | 5798.04 | 3797.68 | 0.000127 |
HEAT PUMP COOLING MODE AIRLOOP M NW | 0.312163 | 6020.88 | 3963.78 | 0.000132 |
HEAT PUMP COOLING MODE AIRLOOP M SE | 0.244615 | 5006.93 | 3213.01 | 0.000109 |
HEAT PUMP COOLING MODE AIRLOOP M NE | 0.249668 | 5075.18 | 3265.26 | 0.000111 |
HEAT PUMP COOLING MODE AIRLOOP M N1 | 0.174602 | 3741.14 | 2360.73 | 0.000082 |
HEAT PUMP COOLING MODE AIRLOOP M N2 | 0.173544 | 3725.04 | 2349.02 | 0.000081 |
HEAT PUMP COOLING MODE AIRLOOP M S1 | 0.154268 | 3428.91 | 2135.75 | 0.000075 |
HEAT PUMP COOLING MODE AIRLOOP M S2 | 0.153947 | 3454.89 | 2147.24 | 0.000075 |
HEAT PUMP COOLING MODE AIRLOOP F6 SW | 0.294740 | 5807.28 | 3787.85 | 0.000127 |
HEAT PUMP COOLING MODE AIRLOOP F6 NW | 0.309751 | 6027.95 | 3951.79 | 0.000132 |
HEAT PUMP COOLING MODE AIRLOOP F6 SE | 0.241890 | 5004.87 | 3197.12 | 0.000109 |
HEAT PUMP COOLING MODE AIRLOOP F6 NE | 0.246781 | 5071.14 | 3247.63 | 0.000111 |
HEAT PUMP COOLING MODE AIRLOOP F6 N1 | 0.172500 | 3732.06 | 2346.19 | 0.000082 |
HEAT PUMP COOLING MODE AIRLOOP F6 N2 | 0.171447 | 3715.94 | 2334.52 | 0.000081 |
HEAT PUMP COOLING MODE AIRLOOP F6 S1 | 0.152451 | 3422.08 | 2123.99 | 0.000075 |
HEAT PUMP COOLING MODE AIRLOOP F6 S2 | 0.152098 | 3447.63 | 2135.03 | 0.000075 |
HEAT PUMP COOLING MODE AIRLOOP F7 SW | 0.294444 | 5839.18 | 3797.27 | 0.000128 |
HEAT PUMP COOLING MODE AIRLOOP F7 NW | 0.309371 | 6059.31 | 3960.40 | 0.000132 |
HEAT PUMP COOLING MODE AIRLOOP F7 SE | 0.241131 | 5027.06 | 3201.16 | 0.000110 |
HEAT PUMP COOLING MODE AIRLOOP F7 NE | 0.245956 | 5092.68 | 3250.98 | 0.000111 |
HEAT PUMP COOLING MODE AIRLOOP F7 N1 | 0.172309 | 3748.82 | 2351.63 | 0.000082 |
HEAT PUMP COOLING MODE AIRLOOP F7 N2 | 0.171273 | 3738.74 | 2342.98 | 0.000082 |
HEAT PUMP COOLING MODE AIRLOOP F7 S1 | 0.152403 | 3439.66 | 2130.75 | 0.000075 |
HEAT PUMP COOLING MODE AIRLOOP F7 S2 | 0.152032 | 3464.95 | 2141.55 | 0.000076 |
HEAT PUMP COOLING MODE AIRLOOP F8 SW | 0.295390 | 5885.54 | 3819.10 | 0.000129 |
HEAT PUMP COOLING MODE AIRLOOP F8 NW | 0.310252 | 6105.26 | 3981.58 | 0.000133 |
HEAT PUMP COOLING MODE AIRLOOP F8 SE | 0.241599 | 5063.99 | 3217.44 | 0.000111 |
HEAT PUMP COOLING MODE AIRLOOP F8 NE | 0.246352 | 5128.81 | 3266.52 | 0.000112 |
HEAT PUMP COOLING MODE AIRLOOP F8 N1 | 0.173363 | 3788.32 | 2372.90 | 0.000083 |
HEAT PUMP COOLING MODE AIRLOOP F8 N2 | 0.172335 | 3772.41 | 2361.46 | 0.000082 |
HEAT PUMP COOLING MODE AIRLOOP F8 S1 | 0.153570 | 3474.14 | 2150.23 | 0.000076 |
HEAT PUMP COOLING MODE AIRLOOP F8 S2 | 0.153110 | 3497.97 | 2160.00 | 0.000076 |
HEAT PUMP COOLING MODE AIRLOOP F9 SW | 0.305011 | 6058.01 | 3935.09 | 0.000132 |
HEAT PUMP COOLING MODE AIRLOOP F9 NW | 0.320069 | 6280.73 | 4100.43 | 0.000137 |
HEAT PUMP COOLING MODE AIRLOOP F9 SE | 0.246484 | 5167.55 | 3282.99 | 0.000113 |
HEAT PUMP COOLING MODE AIRLOOP F9 NE | 0.250954 | 5226.28 | 3327.73 | 0.000114 |
HEAT PUMP COOLING MODE AIRLOOP F9 N1 | 0.182223 | 3933.58 | 2474.06 | 0.000086 |
HEAT PUMP COOLING MODE AIRLOOP F9 N2 | 0.181170 | 3917.41 | 2462.38 | 0.000086 |
HEAT PUMP COOLING MODE AIRLOOP F9 S1 | 0.162442 | 3627.29 | 2254.74 | 0.000079 |
HEAT PUMP COOLING MODE AIRLOOP F9 S2 | 0.161433 | 3611.35 | 2243.43 | 0.000079 |
HEAT PUMP COOLING MODE AIRLOOP T SW | 0.367908 | 7019.59 | 4642.32 | 0.000153 |
HEAT PUMP COOLING MODE AIRLOOP T NW | 0.378428 | 7167.59 | 4755.05 | 0.000157 |
HEAT PUMP COOLING MODE AIRLOOP T SE | 0.304103 | 6064.54 | 3931.73 | 0.000132 |
HEAT PUMP COOLING MODE AIRLOOP T NE | 0.305700 | 6083.65 | 3947.07 | 0.000133 |
HEAT PUMP COOLING MODE AIRLOOP T N1 | 0.223964 | 4575.97 | 2941.24 | 0.000100 |
HEAT PUMP COOLING MODE AIRLOOP T N2 | 0.221673 | 4541.53 | 2915.86 | 0.000099 |
HEAT PUMP COOLING MODE AIRLOOP T S1 | 0.226153 | 4636.37 | 2980.13 | 0.000101 |
HEAT PUMP COOLING MODE AIRLOOP T S2 | 0.226488 | 4640.93 | 2983.68 | 0.000101 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Supplemental Heating Coil Nominal Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
AIRLOOP G SW DXAC HEAT PUMP | 0.241276 | 0.241276 | 0.241276 | 0.241276 | 4657.48 | 4657.48 | 1633.64 | 1.00 |
AIRLOOP G NW DXAC HEAT PUMP | 0.255539 | 0.255539 | 0.255539 | 0.255539 | 4863.02 | 4863.02 | 1628.22 | 1.00 |
AIRLOOP OFFICE DXAC HEAT PUMP | 0.333019 | 0.333019 | 0.333019 | 0.333019 | 6318.01 | 6318.01 | 2118.13 | 1.00 |
AIRLOOP G NE DXAC HEAT PUMP | 0.202794 | 0.202794 | 0.202794 | 0.202794 | 4067.74 | 4067.74 | 1630.75 | 1.00 |
AIRLOOP G N1 DXAC HEAT PUMP | 0.133702 | 0.133702 | 0.133702 | 0.133702 | 2953.10 | 2953.10 | 1092.87 | 1.00 |
AIRLOOP G N2 DXAC HEAT PUMP | 0.132367 | 0.132367 | 0.132367 | 0.132367 | 2932.89 | 2932.89 | 1092.92 | 1.00 |
AIRLOOP G S1 DXAC HEAT PUMP | 0.114106 | 0.114106 | 0.114106 | 0.114106 | 2652.61 | 2652.61 | 1094.13 | 1.00 |
AIRLOOP G S2 DXAC HEAT PUMP | 0.119052 | 0.119052 | 0.119052 | 0.119052 | 2760.08 | 2760.08 | 1099.07 | 1.00 |
AIRLOOP F2 SW DXAC HEAT PUMP | 0.291236 | 0.291236 | 0.291236 | 0.291236 | 5520.21 | 5520.21 | 1791.44 | 1.00 |
AIRLOOP F2 NW DXAC HEAT PUMP | 0.306607 | 0.306607 | 0.306607 | 0.306607 | 5743.42 | 5743.42 | 1790.24 | 1.00 |
AIRLOOP F2 SE DXAC HEAT PUMP | 0.261354 | 0.261354 | 0.261354 | 0.261354 | 5069.75 | 5069.75 | 1810.20 | 1.00 |
AIRLOOP F2 NE DXAC HEAT PUMP | 0.245436 | 0.245436 | 0.245436 | 0.245436 | 4824.96 | 4824.96 | 1790.62 | 1.00 |
AIRLOOP F2 N1 DXAC HEAT PUMP | 0.167209 | 0.167209 | 0.167209 | 0.167209 | 3525.90 | 3525.90 | 1115.24 | 1.00 |
AIRLOOP F2 N2 DXAC HEAT PUMP | 0.166145 | 0.166145 | 0.166145 | 0.166145 | 3509.93 | 3509.93 | 1115.25 | 1.00 |
AIRLOOP F2 S1 DXAC HEAT PUMP | 0.146383 | 0.146383 | 0.146383 | 0.146383 | 3211.16 | 3211.16 | 1117.85 | 1.00 |
AIRLOOP F2 S2 DXAC HEAT PUMP | 0.146915 | 0.146915 | 0.146915 | 0.146915 | 3250.39 | 3250.39 | 1119.13 | 1.00 |
AIRLOOP F3 SW DXAC HEAT PUMP | 0.292255 | 0.292255 | 0.292255 | 0.292255 | 5618.89 | 5618.89 | 1826.61 | 1.00 |
AIRLOOP F3 NW DXAC HEAT PUMP | 0.307680 | 0.307680 | 0.307680 | 0.307680 | 5843.03 | 5843.03 | 1828.78 | 1.00 |
AIRLOOP F3 SE DXAC HEAT PUMP | 0.243375 | 0.243375 | 0.243375 | 0.243375 | 4884.90 | 4884.90 | 1827.15 | 1.00 |
AIRLOOP F3 NE DXAC HEAT PUMP | 0.246649 | 0.246649 | 0.246649 | 0.246649 | 4921.46 | 4921.46 | 1827.21 | 1.00 |
AIRLOOP F3 N1 DXAC HEAT PUMP | 0.169609 | 0.169609 | 0.169609 | 0.169609 | 3606.30 | 3606.30 | 1122.90 | 1.00 |
AIRLOOP F3 N2 DXAC HEAT PUMP | 0.168548 | 0.168548 | 0.168548 | 0.168548 | 3590.28 | 3590.28 | 1122.86 | 1.00 |
AIRLOOP F3 S1 DXAC HEAT PUMP | 0.148924 | 0.148924 | 0.148924 | 0.148924 | 3291.30 | 3291.30 | 1119.90 | 1.00 |
AIRLOOP F3 S2 DXAC HEAT PUMP | 0.148815 | 0.148815 | 0.148815 | 0.148815 | 3320.73 | 3320.73 | 1120.07 | 1.00 |
AIRLOOP F4 SW DXAC HEAT PUMP | 0.293716 | 0.293716 | 0.293716 | 0.293716 | 5701.31 | 5701.31 | 1870.73 | 1.00 |
AIRLOOP F4 NW DXAC HEAT PUMP | 0.308980 | 0.308980 | 0.308980 | 0.308980 | 5924.10 | 5924.10 | 1875.55 | 1.00 |
AIRLOOP F4 SE DXAC HEAT PUMP | 0.242248 | 0.242248 | 0.242248 | 0.242248 | 4925.51 | 4925.51 | 1867.86 | 1.00 |
AIRLOOP F4 NE DXAC HEAT PUMP | 0.247145 | 0.247145 | 0.247145 | 0.247145 | 4991.07 | 4991.07 | 1872.47 | 1.00 |
AIRLOOP F4 N1 DXAC HEAT PUMP | 0.171269 | 0.171269 | 0.171269 | 0.171269 | 3664.22 | 3664.22 | 1145.39 | 1.00 |
AIRLOOP F4 N2 DXAC HEAT PUMP | 0.170209 | 0.170209 | 0.170209 | 0.170209 | 3648.15 | 3648.15 | 1145.31 | 1.00 |
AIRLOOP F4 S1 DXAC HEAT PUMP | 0.150837 | 0.150837 | 0.150837 | 0.150837 | 3351.33 | 3351.33 | 1139.31 | 1.00 |
AIRLOOP F4 S2 DXAC HEAT PUMP | 0.150556 | 0.150556 | 0.150556 | 0.150556 | 3378.06 | 3378.06 | 1139.26 | 1.00 |
AIRLOOP M SW DXAC HEAT PUMP | 0.296945 | 0.296945 | 0.296945 | 0.296945 | 5798.04 | 5798.04 | 1890.21 | 1.00 |
AIRLOOP M NW DXAC HEAT PUMP | 0.312163 | 0.312163 | 0.312163 | 0.312163 | 6020.88 | 6020.88 | 1896.05 | 1.00 |
AIRLOOP M SE DXAC HEAT PUMP | 0.244615 | 0.244615 | 0.244615 | 0.244615 | 5006.93 | 5006.93 | 1885.89 | 1.00 |
AIRLOOP M NE DXAC HEAT PUMP | 0.249668 | 0.249668 | 0.249668 | 0.249668 | 5075.18 | 5075.18 | 1891.73 | 1.00 |
AIRLOOP M N1 DXAC HEAT PUMP | 0.174602 | 0.174602 | 0.174602 | 0.174602 | 3741.14 | 3741.14 | 1148.34 | 1.00 |
AIRLOOP M N2 DXAC HEAT PUMP | 0.173544 | 0.173544 | 0.173544 | 0.173544 | 3725.04 | 3725.04 | 1148.22 | 1.00 |
AIRLOOP M S1 DXAC HEAT PUMP | 0.154268 | 0.154268 | 0.154268 | 0.154268 | 3428.91 | 3428.91 | 1141.08 | 1.00 |
AIRLOOP M S2 DXAC HEAT PUMP | 0.153947 | 0.153947 | 0.153947 | 0.153947 | 3454.89 | 3454.89 | 1140.97 | 1.00 |
AIRLOOP F6 SW DXAC HEAT PUMP | 0.294740 | 0.294740 | 0.294740 | 0.294740 | 5807.28 | 5807.28 | 1964.42 | 1.00 |
AIRLOOP F6 NW DXAC HEAT PUMP | 0.309751 | 0.309751 | 0.309751 | 0.309751 | 6027.95 | 6027.95 | 1972.77 | 1.00 |
AIRLOOP F6 SE DXAC HEAT PUMP | 0.241890 | 0.241890 | 0.241890 | 0.241890 | 5004.87 | 5004.87 | 1959.01 | 1.00 |
AIRLOOP F6 NE DXAC HEAT PUMP | 0.246781 | 0.246781 | 0.246781 | 0.246781 | 5071.14 | 5071.14 | 1967.38 | 1.00 |
AIRLOOP F6 N1 DXAC HEAT PUMP | 0.172500 | 0.172500 | 0.172500 | 0.172500 | 3732.06 | 3732.06 | 1205.55 | 1.00 |
AIRLOOP F6 N2 DXAC HEAT PUMP | 0.171447 | 0.171447 | 0.171447 | 0.171447 | 3715.94 | 3715.94 | 1205.41 | 1.00 |
AIRLOOP F6 S1 DXAC HEAT PUMP | 0.152451 | 0.152451 | 0.152451 | 0.152451 | 3422.08 | 3422.08 | 1195.66 | 1.00 |
AIRLOOP F6 S2 DXAC HEAT PUMP | 0.152098 | 0.152098 | 0.152098 | 0.152098 | 3447.63 | 3447.63 | 1195.52 | 1.00 |
AIRLOOP F7 SW DXAC HEAT PUMP | 0.294444 | 0.294444 | 0.294444 | 0.294444 | 5839.18 | 5839.18 | 2013.46 | 1.00 |
AIRLOOP F7 NW DXAC HEAT PUMP | 0.309371 | 0.309371 | 0.309371 | 0.309371 | 6059.31 | 6059.31 | 2023.00 | 1.00 |
AIRLOOP F7 SE DXAC HEAT PUMP | 0.241131 | 0.241131 | 0.241131 | 0.241131 | 5027.06 | 5027.06 | 2007.11 | 1.00 |
AIRLOOP F7 NE DXAC HEAT PUMP | 0.245956 | 0.245956 | 0.245956 | 0.245956 | 5092.68 | 5092.68 | 2016.69 | 1.00 |
AIRLOOP F7 N1 DXAC HEAT PUMP | 0.172309 | 0.172309 | 0.172309 | 0.172309 | 3748.82 | 3748.82 | 1240.79 | 1.00 |
AIRLOOP F7 N2 DXAC HEAT PUMP | 0.171273 | 0.171273 | 0.171273 | 0.171273 | 3738.74 | 3738.74 | 1240.63 | 1.00 |
AIRLOOP F7 S1 DXAC HEAT PUMP | 0.152403 | 0.152403 | 0.152403 | 0.152403 | 3439.66 | 3439.66 | 1229.59 | 1.00 |
AIRLOOP F7 S2 DXAC HEAT PUMP | 0.152032 | 0.152032 | 0.152032 | 0.152032 | 3464.95 | 3464.95 | 1229.42 | 1.00 |
AIRLOOP F8 SW DXAC HEAT PUMP | 0.295390 | 0.295390 | 0.295390 | 0.295390 | 5885.54 | 5885.54 | 2060.57 | 1.00 |
AIRLOOP F8 NW DXAC HEAT PUMP | 0.310252 | 0.310252 | 0.310252 | 0.310252 | 6105.26 | 6105.26 | 2070.97 | 1.00 |
AIRLOOP F8 SE DXAC HEAT PUMP | 0.241599 | 0.241599 | 0.241599 | 0.241599 | 5063.99 | 5063.99 | 2053.40 | 1.00 |
AIRLOOP F8 NE DXAC HEAT PUMP | 0.246352 | 0.246352 | 0.246352 | 0.246352 | 5128.81 | 5128.81 | 2063.84 | 1.00 |
AIRLOOP F8 N1 DXAC HEAT PUMP | 0.173363 | 0.173363 | 0.173363 | 0.173363 | 3788.32 | 3788.32 | 1275.42 | 1.00 |
AIRLOOP F8 N2 DXAC HEAT PUMP | 0.172335 | 0.172335 | 0.172335 | 0.172335 | 3772.41 | 3772.41 | 1275.23 | 1.00 |
AIRLOOP F8 S1 DXAC HEAT PUMP | 0.153570 | 0.153570 | 0.153570 | 0.153570 | 3474.14 | 3474.14 | 1263.29 | 1.00 |
AIRLOOP F8 S2 DXAC HEAT PUMP | 0.153110 | 0.153110 | 0.153110 | 0.153110 | 3497.97 | 3497.97 | 1263.10 | 1.00 |
AIRLOOP F9 SW DXAC HEAT PUMP | 0.305011 | 0.305011 | 0.305011 | 0.305011 | 6058.01 | 6058.01 | 2172.08 | 1.00 |
AIRLOOP F9 NW DXAC HEAT PUMP | 0.320069 | 0.320069 | 0.320069 | 0.320069 | 6280.73 | 6280.73 | 2181.16 | 1.00 |
AIRLOOP F9 SE DXAC HEAT PUMP | 0.246484 | 0.246484 | 0.246484 | 0.246484 | 5167.55 | 5167.55 | 2164.11 | 1.00 |
AIRLOOP F9 NE DXAC HEAT PUMP | 0.250954 | 0.250954 | 0.250954 | 0.250954 | 5226.28 | 5226.28 | 2173.24 | 1.00 |
AIRLOOP F9 N1 DXAC HEAT PUMP | 0.182223 | 0.182223 | 0.182223 | 0.182223 | 3933.58 | 3933.58 | 1367.38 | 1.00 |
AIRLOOP F9 N2 DXAC HEAT PUMP | 0.181170 | 0.181170 | 0.181170 | 0.181170 | 3917.41 | 3917.41 | 1367.17 | 1.00 |
AIRLOOP F9 S1 DXAC HEAT PUMP | 0.162442 | 0.162442 | 0.162442 | 0.162442 | 3627.29 | 3627.29 | 1356.29 | 1.00 |
AIRLOOP F9 S2 DXAC HEAT PUMP | 0.161433 | 0.161433 | 0.161433 | 0.161433 | 3611.35 | 3611.35 | 1356.08 | 1.00 |
AIRLOOP T SW DXAC HEAT PUMP | 0.367908 | 0.367908 | 0.367908 | 0.367908 | 7019.59 | 7019.59 | 2412.28 | 1.00 |
AIRLOOP T NW DXAC HEAT PUMP | 0.378428 | 0.378428 | 0.378428 | 0.378428 | 7167.59 | 7167.59 | 2425.75 | 1.00 |
AIRLOOP T SE DXAC HEAT PUMP | 0.304103 | 0.304103 | 0.304103 | 0.304103 | 6064.54 | 6064.54 | 2404.52 | 1.00 |
AIRLOOP T NE DXAC HEAT PUMP | 0.305700 | 0.305700 | 0.305700 | 0.305700 | 6083.65 | 6083.65 | 2418.02 | 1.00 |
AIRLOOP T N1 DXAC HEAT PUMP | 0.223964 | 0.223964 | 0.223964 | 0.223964 | 4575.97 | 4575.97 | 1654.01 | 1.00 |
AIRLOOP T N2 DXAC HEAT PUMP | 0.221673 | 0.221673 | 0.221673 | 0.221673 | 4541.53 | 4541.53 | 1653.79 | 1.00 |
AIRLOOP T S1 DXAC HEAT PUMP | 0.226153 | 0.226153 | 0.226153 | 0.226153 | 4636.37 | 4636.37 | 1637.31 | 1.00 |
AIRLOOP T S2 DXAC HEAT PUMP | 0.226488 | 0.226488 | 0.226488 | 0.226488 | 4640.93 | 4640.93 | 1637.09 | 1.00 |
Maximum Flow Rate [m3/s] | |
AIRLOOP G SW SUPPLY FAN | 0.241276 |
AIRLOOP G NW SUPPLY FAN | 0.255539 |
AIRLOOP OFFICE SUPPLY FAN | 0.333019 |
AIRLOOP G NE SUPPLY FAN | 0.202794 |
AIRLOOP G N1 SUPPLY FAN | 0.133702 |
AIRLOOP G N2 SUPPLY FAN | 0.132367 |
AIRLOOP G S1 SUPPLY FAN | 0.114106 |
AIRLOOP G S2 SUPPLY FAN | 0.119052 |
AIRLOOP F2 SW SUPPLY FAN | 0.291236 |
AIRLOOP F2 NW SUPPLY FAN | 0.306607 |
AIRLOOP F2 SE SUPPLY FAN | 0.261354 |
AIRLOOP F2 NE SUPPLY FAN | 0.245436 |
AIRLOOP F2 N1 SUPPLY FAN | 0.167209 |
AIRLOOP F2 N2 SUPPLY FAN | 0.166145 |
AIRLOOP F2 S1 SUPPLY FAN | 0.146383 |
AIRLOOP F2 S2 SUPPLY FAN | 0.146915 |
AIRLOOP F3 SW SUPPLY FAN | 0.292255 |
AIRLOOP F3 NW SUPPLY FAN | 0.307680 |
AIRLOOP F3 SE SUPPLY FAN | 0.243375 |
AIRLOOP F3 NE SUPPLY FAN | 0.246649 |
AIRLOOP F3 N1 SUPPLY FAN | 0.169609 |
AIRLOOP F3 N2 SUPPLY FAN | 0.168548 |
AIRLOOP F3 S1 SUPPLY FAN | 0.148924 |
AIRLOOP F3 S2 SUPPLY FAN | 0.148815 |
AIRLOOP F4 SW SUPPLY FAN | 0.293716 |
AIRLOOP F4 NW SUPPLY FAN | 0.308980 |
AIRLOOP F4 SE SUPPLY FAN | 0.242248 |
AIRLOOP F4 NE SUPPLY FAN | 0.247145 |
AIRLOOP F4 N1 SUPPLY FAN | 0.171269 |
AIRLOOP F4 N2 SUPPLY FAN | 0.170209 |
AIRLOOP F4 S1 SUPPLY FAN | 0.150837 |
AIRLOOP F4 S2 SUPPLY FAN | 0.150556 |
AIRLOOP M SW SUPPLY FAN | 0.296945 |
AIRLOOP M NW SUPPLY FAN | 0.312163 |
AIRLOOP M SE SUPPLY FAN | 0.244615 |
AIRLOOP M NE SUPPLY FAN | 0.249668 |
AIRLOOP M N1 SUPPLY FAN | 0.174602 |
AIRLOOP M N2 SUPPLY FAN | 0.173544 |
AIRLOOP M S1 SUPPLY FAN | 0.154268 |
AIRLOOP M S2 SUPPLY FAN | 0.153947 |
AIRLOOP F6 SW SUPPLY FAN | 0.294740 |
AIRLOOP F6 NW SUPPLY FAN | 0.309751 |
AIRLOOP F6 SE SUPPLY FAN | 0.241890 |
AIRLOOP F6 NE SUPPLY FAN | 0.246781 |
AIRLOOP F6 N1 SUPPLY FAN | 0.172500 |
AIRLOOP F6 N2 SUPPLY FAN | 0.171447 |
AIRLOOP F6 S1 SUPPLY FAN | 0.152451 |
AIRLOOP F6 S2 SUPPLY FAN | 0.152098 |
AIRLOOP F7 SW SUPPLY FAN | 0.294444 |
AIRLOOP F7 NW SUPPLY FAN | 0.309371 |
AIRLOOP F7 SE SUPPLY FAN | 0.241131 |
AIRLOOP F7 NE SUPPLY FAN | 0.245956 |
AIRLOOP F7 N1 SUPPLY FAN | 0.172309 |
AIRLOOP F7 N2 SUPPLY FAN | 0.171273 |
AIRLOOP F7 S1 SUPPLY FAN | 0.152403 |
AIRLOOP F7 S2 SUPPLY FAN | 0.152032 |
AIRLOOP F8 SW SUPPLY FAN | 0.295390 |
AIRLOOP F8 NW SUPPLY FAN | 0.310252 |
AIRLOOP F8 SE SUPPLY FAN | 0.241599 |
AIRLOOP F8 NE SUPPLY FAN | 0.246352 |
AIRLOOP F8 N1 SUPPLY FAN | 0.173363 |
AIRLOOP F8 N2 SUPPLY FAN | 0.172335 |
AIRLOOP F8 S1 SUPPLY FAN | 0.153570 |
AIRLOOP F8 S2 SUPPLY FAN | 0.153110 |
AIRLOOP F9 SW SUPPLY FAN | 0.305011 |
AIRLOOP F9 NW SUPPLY FAN | 0.320069 |
AIRLOOP F9 SE SUPPLY FAN | 0.246484 |
AIRLOOP F9 NE SUPPLY FAN | 0.250954 |
AIRLOOP F9 N1 SUPPLY FAN | 0.182223 |
AIRLOOP F9 N2 SUPPLY FAN | 0.181170 |
AIRLOOP F9 S1 SUPPLY FAN | 0.162442 |
AIRLOOP F9 S2 SUPPLY FAN | 0.161433 |
AIRLOOP T SW SUPPLY FAN | 0.367908 |
AIRLOOP T NW SUPPLY FAN | 0.378428 |
AIRLOOP T SE SUPPLY FAN | 0.304103 |
AIRLOOP T NE SUPPLY FAN | 0.305700 |
AIRLOOP T N1 SUPPLY FAN | 0.223964 |
AIRLOOP T N2 SUPPLY FAN | 0.221673 |
AIRLOOP T S1 SUPPLY FAN | 0.226153 |
AIRLOOP T S2 SUPPLY FAN | 0.226488 |
Rated Air Flow Rate [m3/s] | Rated Heating Capacity [W] | Rated Water Flow Rate [m3/s] | |
HEAT PUMP HEATING MODE AIRLOOP G SW | 0.241276 | 4657.48 | 0.000102 |
HEAT PUMP HEATING MODE AIRLOOP G NW | 0.255539 | 4863.02 | 0.000106 |
HEAT PUMP HEATING MODE AIRLOOP OFFICE | 0.333019 | 6318.01 | 0.000138 |
HEAT PUMP HEATING MODE AIRLOOP G NE | 0.202794 | 4067.74 | 0.000089 |
HEAT PUMP HEATING MODE AIRLOOP G N1 | 0.133702 | 2953.10 | 0.000065 |
HEAT PUMP HEATING MODE AIRLOOP G N2 | 0.132367 | 2932.89 | 0.000064 |
HEAT PUMP HEATING MODE AIRLOOP G S1 | 0.114106 | 2652.61 | 0.000058 |
HEAT PUMP HEATING MODE AIRLOOP G S2 | 0.119052 | 2760.08 | 0.000060 |
HEAT PUMP HEATING MODE AIRLOOP F2 SW | 0.291236 | 5520.21 | 0.000121 |
HEAT PUMP HEATING MODE AIRLOOP F2 NW | 0.306607 | 5743.42 | 0.000125 |
HEAT PUMP HEATING MODE AIRLOOP F2 SE | 0.261354 | 5069.75 | 0.000111 |
HEAT PUMP HEATING MODE AIRLOOP F2 NE | 0.245436 | 4824.96 | 0.000105 |
HEAT PUMP HEATING MODE AIRLOOP F2 N1 | 0.167209 | 3525.90 | 0.000077 |
HEAT PUMP HEATING MODE AIRLOOP F2 N2 | 0.166145 | 3509.93 | 0.000077 |
HEAT PUMP HEATING MODE AIRLOOP F2 S1 | 0.146383 | 3211.16 | 0.000070 |
HEAT PUMP HEATING MODE AIRLOOP F2 S2 | 0.146915 | 3250.39 | 0.000071 |
HEAT PUMP HEATING MODE AIRLOOP F3 SW | 0.292255 | 5618.89 | 0.000123 |
HEAT PUMP HEATING MODE AIRLOOP F3 NW | 0.307680 | 5843.03 | 0.000128 |
HEAT PUMP HEATING MODE AIRLOOP F3 SE | 0.243375 | 4884.90 | 0.000107 |
HEAT PUMP HEATING MODE AIRLOOP F3 NE | 0.246649 | 4921.46 | 0.000108 |
HEAT PUMP HEATING MODE AIRLOOP F3 N1 | 0.169609 | 3606.30 | 0.000079 |
HEAT PUMP HEATING MODE AIRLOOP F3 N2 | 0.168548 | 3590.28 | 0.000078 |
HEAT PUMP HEATING MODE AIRLOOP F3 S1 | 0.148924 | 3291.30 | 0.000072 |
HEAT PUMP HEATING MODE AIRLOOP F3 S2 | 0.148815 | 3320.73 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F4 SW | 0.293716 | 5701.31 | 0.000125 |
HEAT PUMP HEATING MODE AIRLOOP F4 NW | 0.308980 | 5924.10 | 0.000129 |
HEAT PUMP HEATING MODE AIRLOOP F4 SE | 0.242248 | 4925.51 | 0.000108 |
HEAT PUMP HEATING MODE AIRLOOP F4 NE | 0.247145 | 4991.07 | 0.000109 |
HEAT PUMP HEATING MODE AIRLOOP F4 N1 | 0.171269 | 3664.22 | 0.000080 |
HEAT PUMP HEATING MODE AIRLOOP F4 N2 | 0.170209 | 3648.15 | 0.000080 |
HEAT PUMP HEATING MODE AIRLOOP F4 S1 | 0.150837 | 3351.33 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F4 S2 | 0.150556 | 3378.06 | 0.000074 |
HEAT PUMP HEATING MODE AIRLOOP M SW | 0.296945 | 5798.04 | 0.000127 |
HEAT PUMP HEATING MODE AIRLOOP M NW | 0.312163 | 6020.88 | 0.000132 |
HEAT PUMP HEATING MODE AIRLOOP M SE | 0.244615 | 5006.93 | 0.000109 |
HEAT PUMP HEATING MODE AIRLOOP M NE | 0.249668 | 5075.18 | 0.000111 |
HEAT PUMP HEATING MODE AIRLOOP M N1 | 0.174602 | 3741.14 | 0.000082 |
HEAT PUMP HEATING MODE AIRLOOP M N2 | 0.173544 | 3725.04 | 0.000081 |
HEAT PUMP HEATING MODE AIRLOOP M S1 | 0.154268 | 3428.91 | 0.000075 |
HEAT PUMP HEATING MODE AIRLOOP M S2 | 0.153947 | 3454.89 | 0.000075 |
HEAT PUMP HEATING MODE AIRLOOP F6 SW | 0.294740 | 5807.28 | 0.000127 |
HEAT PUMP HEATING MODE AIRLOOP F6 NW | 0.309751 | 6027.95 | 0.000132 |
HEAT PUMP HEATING MODE AIRLOOP F6 SE | 0.241890 | 5004.87 | 0.000109 |
HEAT PUMP HEATING MODE AIRLOOP F6 NE | 0.246781 | 5071.14 | 0.000111 |
HEAT PUMP HEATING MODE AIRLOOP F6 N1 | 0.172500 | 3732.06 | 0.000082 |
HEAT PUMP HEATING MODE AIRLOOP F6 N2 | 0.171447 | 3715.94 | 0.000081 |
HEAT PUMP HEATING MODE AIRLOOP F6 S1 | 0.152451 | 3422.08 | 0.000075 |
HEAT PUMP HEATING MODE AIRLOOP F6 S2 | 0.152098 | 3447.63 | 0.000075 |
HEAT PUMP HEATING MODE AIRLOOP F7 SW | 0.294444 | 5839.18 | 0.000128 |
HEAT PUMP HEATING MODE AIRLOOP F7 NW | 0.309371 | 6059.31 | 0.000132 |
HEAT PUMP HEATING MODE AIRLOOP F7 SE | 0.241131 | 5027.06 | 0.000110 |
HEAT PUMP HEATING MODE AIRLOOP F7 NE | 0.245956 | 5092.68 | 0.000111 |
HEAT PUMP HEATING MODE AIRLOOP F7 N1 | 0.172309 | 3748.82 | 0.000082 |
HEAT PUMP HEATING MODE AIRLOOP F7 N2 | 0.171273 | 3738.74 | 0.000082 |
HEAT PUMP HEATING MODE AIRLOOP F7 S1 | 0.152403 | 3439.66 | 0.000075 |
HEAT PUMP HEATING MODE AIRLOOP F7 S2 | 0.152032 | 3464.95 | 0.000076 |
HEAT PUMP HEATING MODE AIRLOOP F8 SW | 0.295390 | 5885.54 | 0.000129 |
HEAT PUMP HEATING MODE AIRLOOP F8 NW | 0.310252 | 6105.26 | 0.000133 |
HEAT PUMP HEATING MODE AIRLOOP F8 SE | 0.241599 | 5063.99 | 0.000111 |
HEAT PUMP HEATING MODE AIRLOOP F8 NE | 0.246352 | 5128.81 | 0.000112 |
HEAT PUMP HEATING MODE AIRLOOP F8 N1 | 0.173363 | 3788.32 | 0.000083 |
HEAT PUMP HEATING MODE AIRLOOP F8 N2 | 0.172335 | 3772.41 | 0.000082 |
HEAT PUMP HEATING MODE AIRLOOP F8 S1 | 0.153570 | 3474.14 | 0.000076 |
HEAT PUMP HEATING MODE AIRLOOP F8 S2 | 0.153110 | 3497.97 | 0.000076 |
HEAT PUMP HEATING MODE AIRLOOP F9 SW | 0.305011 | 6058.01 | 0.000132 |
HEAT PUMP HEATING MODE AIRLOOP F9 NW | 0.320069 | 6280.73 | 0.000137 |
HEAT PUMP HEATING MODE AIRLOOP F9 SE | 0.246484 | 5167.55 | 0.000113 |
HEAT PUMP HEATING MODE AIRLOOP F9 NE | 0.250954 | 5226.28 | 0.000114 |
HEAT PUMP HEATING MODE AIRLOOP F9 N1 | 0.182223 | 3933.58 | 0.000086 |
HEAT PUMP HEATING MODE AIRLOOP F9 N2 | 0.181170 | 3917.41 | 0.000086 |
HEAT PUMP HEATING MODE AIRLOOP F9 S1 | 0.162442 | 3627.29 | 0.000079 |
HEAT PUMP HEATING MODE AIRLOOP F9 S2 | 0.161433 | 3611.35 | 0.000079 |
HEAT PUMP HEATING MODE AIRLOOP T SW | 0.367908 | 7019.59 | 0.000153 |
HEAT PUMP HEATING MODE AIRLOOP T NW | 0.378428 | 7167.59 | 0.000157 |
HEAT PUMP HEATING MODE AIRLOOP T SE | 0.304103 | 6064.54 | 0.000132 |
HEAT PUMP HEATING MODE AIRLOOP T NE | 0.305700 | 6083.65 | 0.000133 |
HEAT PUMP HEATING MODE AIRLOOP T N1 | 0.223964 | 4575.97 | 0.000100 |
HEAT PUMP HEATING MODE AIRLOOP T N2 | 0.221673 | 4541.53 | 0.000099 |
HEAT PUMP HEATING MODE AIRLOOP T S1 | 0.226153 | 4636.37 | 0.000101 |
HEAT PUMP HEATING MODE AIRLOOP T S2 | 0.226488 | 4640.93 | 0.000101 |
Nominal Capacity [W] | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW | 1633.64 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW | 1628.22 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE | 2118.13 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE | 1630.75 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 | 1092.87 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 | 1092.92 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 | 1094.13 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 | 1099.07 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW | 1791.44 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW | 1790.24 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE | 1810.20 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE | 1790.62 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 | 1115.24 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 | 1115.25 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 | 1117.85 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 | 1119.13 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW | 1826.61 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW | 1828.78 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE | 1827.15 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE | 1827.21 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 | 1122.90 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 | 1122.86 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 | 1119.90 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 | 1120.07 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW | 1870.73 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW | 1875.55 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE | 1867.86 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE | 1872.47 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 | 1145.39 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 | 1145.31 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 | 1139.31 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 | 1139.26 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW | 1890.21 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW | 1896.05 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE | 1885.89 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE | 1891.73 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 | 1148.34 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 | 1148.22 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 | 1141.08 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 | 1140.97 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW | 1964.42 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW | 1972.77 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE | 1959.01 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE | 1967.38 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 | 1205.55 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 | 1205.41 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 | 1195.66 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 | 1195.52 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW | 2013.46 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW | 2023.00 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE | 2007.11 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE | 2016.69 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 | 1240.79 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 | 1240.63 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 | 1229.59 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 | 1229.42 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW | 2060.57 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW | 2070.97 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE | 2053.40 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE | 2063.84 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 | 1275.42 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 | 1275.23 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 | 1263.29 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 | 1263.10 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW | 2172.08 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW | 2181.16 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE | 2164.11 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE | 2173.24 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 | 1367.38 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 | 1367.17 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 | 1356.29 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 | 1356.08 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW | 2412.28 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW | 2425.75 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE | 2404.52 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE | 2418.02 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 | 1654.01 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 | 1653.79 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 | 1637.31 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 | 1637.09 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
SHWSYS1 | 0.000289 | 0.325214 |
SINGLE WATER PLANT LOOP | 0.007966 | 8.96 |
Design Water Flow Rate [m3/s] | |
CENTRAL BOILER | 0.007966 |
Use Side Design Flow Rate [m3/s] | |
SHWSYS1 WATER HEATER | 0.000289 |
Design Water Flow Rate [m3/s] | Fan Power at Design Air Flow Rate [W] | Design Air Flow Rate [m3/s] | U-Factor Times Area Value at Design Air Flow Rate [W/C] | |
CENTRAL TOWER | 0.007966 | 3845.68 | 10.13 | 11919.36 |
Rated Flow Rate [m3/s] | Rated Power Consumption [W] | |
SHWSYS1 PUMP | 0.000289 | 36.93 |
PLANT CIRC PUMP | 0.007966 | 2544.01 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:12:00
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW3 | |
G WWALL SWA | GWINDOW2 | |
G NWALL NWA | GWINDOW4 | |
G WWALL NWA | GWINDOW6 | |
G SWALL SEA | GWINDOW1 | |
G EWALL SEA | GWINDOW8 | |
G NWALL NEA | GWINDOW5 | |
G EWALL NEA | GWINDOW7 | |
G NWALL N1A | GWINDOW9 | |
G NWALL N2A | GWINDOW10 | |
G SWALL S1A | GWINDOW11 | |
G SWALL S2A | GWINDOW12 | |
G WWALL C | GWINDOW13 | |
G EWALL C | ENTRANCE DOOR | |
F2 WWALL SWA | F2WINDOW2 | |
F2 SWALL SWA | F2WINDOW3 | |
F2 NWALL NWA | F2WINDOW4 | |
F2 WWALL NWA | F2WINDOW6 | |
F2 EWALL SEA | F2WINDOW8 | |
F2 SWALL SEA | F2WINDOW1 | |
F2 NWALL NEA | F2WINDOW5 | |
F2 EWALL NEA | F2WINDOW7 | |
F2 NWALL N1A | F2WINDOW9 | |
F2 NWALL N2A | F2WINDOW10 | |
F2 SWALL S1A | F2WINDOW11 | |
F2 SWALL S2A | F2WINDOW12 | |
F2 WWALL C | F2WINDOW13 | |
F2 EWALL C | F2WINDOW14 | |
F3 WWALL SWA | F3WINDOW2 | |
F3 SWALL SWA | F3WINDOW3 | |
F3 NWALL NWA | F3WINDOW4 | |
F3 WWALL NWA | F3WINDOW6 | |
F3 EWALL SEA | F3WINDOW8 | |
F3 SWALL SEA | F3WINDOW1 | |
F3 NWALL NEA | F3WINDOW5 | |
F3 EWALL NEA | F3WINDOW7 | |
F3 NWALL N1A | F3WINDOW9 | |
F3 NWALL N2A | F3WINDOW10 | |
F3 SWALL S1A | F3WINDOW11 | |
F3 SWALL S2A | F3WINDOW12 | |
F3 WWALL C | F3WINDOW13 | |
F3 EWALL C | F3WINDOW14 | |
F4 WWALL SWA | F4WINDOW2 | |
F4 SWALL SWA | F4WINDOW3 | |
F4 NWALL NWA | F4WINDOW4 | |
F4 WWALL NWA | F4WINDOW6 | |
F4 EWALL SEA | F4WINDOW8 | |
F4 SWALL SEA | F4WINDOW1 | |
F4 NWALL NEA | F4WINDOW5 | |
F4 EWALL NEA | F4WINDOW7 | |
F4 NWALL N1A | F4WINDOW9 | |
F4 NWALL N2A | F4WINDOW10 | |
F4 SWALL S1A | F4WINDOW11 | |
F4 SWALL S2A | F4WINDOW12 | |
F4 WWALL C | F4WINDOW13 | |
F4 EWALL C | F4WINDOW14 | |
M WWALL SWA | MWINDOW2 | |
M SWALL SWA | MWINDOW3 | |
M NWALL NWA | MWINDOW4 | |
M WWALL NWA | MWINDOW6 | |
M EWALL SEA | MWINDOW8 | |
M SWALL SEA | MWINDOW1 | |
M NWALL NEA | MWINDOW5 | |
M EWALL NEA | MWINDOW7 | |
M NWALL N1A | MWINDOW9 | |
M NWALL N2A | MWINDOW10 | |
M SWALL S1A | MWINDOW11 | |
M SWALL S2A | MWINDOW12 | |
M WWALL C | MWINDOW13 | |
M EWALL C | MWINDOW14 | |
F6 WWALL SWA | F6WINDOW2 | |
F6 SWALL SWA | F6WINDOW3 | |
F6 NWALL NWA | F6WINDOW4 | |
F6 WWALL NWA | F6WINDOW6 | |
F6 EWALL SEA | F6WINDOW8 | |
F6 SWALL SEA | F6WINDOW1 | |
F6 NWALL NEA | F6WINDOW5 | |
F6 EWALL NEA | F6WINDOW7 | |
F6 NWALL N1A | F6WINDOW9 | |
F6 NWALL N2A | F6WINDOW10 | |
F6 SWALL S1A | F6WINDOW11 | |
F6 SWALL S2A | F6WINDOW12 | |
F6 WWALL C | F6WINDOW13 | |
F6 EWALL C | F6WINDOW14 | |
F7 WWALL SWA | F7WINDOW2 | |
F7 SWALL SWA | F7WINDOW3 | |
F7 NWALL NWA | F7WINDOW4 | |
F7 WWALL NWA | F7WINDOW6 | |
F7 EWALL SEA | F7WINDOW8 | |
F7 SWALL SEA | F7WINDOW1 | |
F7 NWALL NEA | F7WINDOW5 | |
F7 EWALL NEA | F7WINDOW7 | |
F7 NWALL N1A | F7WINDOW9 | |
F7 NWALL N2A | F7WINDOW10 | |
F7 SWALL S1A | F7WINDOW11 | |
F7 SWALL S2A | F7WINDOW12 | |
F7 WWALL C | F7WINDOW13 | |
F7 EWALL C | F7WINDOW14 | |
F8 WWALL SWA | F8WINDOW2 | |
F8 SWALL SWA | F8WINDOW3 | |
F8 NWALL NWA | F8WINDOW4 | |
F8 WWALL NWA | F8WINDOW6 | |
F8 EWALL SEA | F8WINDOW8 | |
F8 SWALL SEA | F8WINDOW1 | |
F8 NWALL NEA | F8WINDOW5 | |
F8 EWALL NEA | F8WINDOW7 | |
F8 NWALL N1A | F8WINDOW9 | |
F8 NWALL N2A | F8WINDOW10 | |
F8 SWALL S1A | F8WINDOW11 | |
F8 SWALL S2A | F8WINDOW12 | |
F8 WWALL C | F8WINDOW13 | |
F8 EWALL C | F8WINDOW14 | |
F9 WWALL SWA | F9WINDOW2 | |
F9 SWALL SWA | F9WINDOW3 | |
F9 NWALL NWA | F9WINDOW4 | |
F9 WWALL NWA | F9WINDOW6 | |
F9 EWALL SEA | F9WINDOW8 | |
F9 SWALL SEA | F9WINDOW1 | |
F9 NWALL NEA | F9WINDOW5 | |
F9 EWALL NEA | F9WINDOW7 | |
F9 NWALL N1A | F9WINDOW9 | |
F9 NWALL N2A | F9WINDOW10 | |
F9 SWALL S1A | F9WINDOW11 | |
F9 SWALL S2A | F9WINDOW12 | |
F9 WWALL C | F9WINDOW13 | |
F9 EWALL C | F9WINDOW14 | |
T WWALL SWA | TWINDOW2 | |
T SWALL SWA | TWINDOW3 | |
T NWALL NWA | TWINDOW4 | |
T WWALL NWA | TWINDOW6 | |
T EWALL SEA | TWINDOW8 | |
T SWALL SEA | TWINDOW1 | |
T NWALL NEA | TWINDOW5 | |
T EWALL NEA | TWINDOW7 | |
T NWALL N1A | TWINDOW9 | |
T NWALL N2A | TWINDOW10 | |
T SWALL S1A | TWINDOW11 | |
T SWALL S2A | TWINDOW12 | |
T WWALL C | TWINDOW13 | |
T EWALL C | TWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2015-09-09 19:12:00
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.81 | 19.42 |
February | 23.95 | 20.87 |
March | 24.04 | 21.57 |
April | 24.35 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.22 | 23.59 |
December | 23.87 | 20.30 |
Annual Sum or Average | 24.22 | 24.51 |
Minimum of Months | 23.81 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.46 | 19.42 |
February | 23.79 | 20.87 |
March | 23.93 | 21.57 |
April | 24.35 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.16 | 23.59 |
December | 23.60 | 20.30 |
Annual Sum or Average | 24.14 | 24.51 |
Minimum of Months | 23.46 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.08 | 19.42 |
February | 24.14 | 20.87 |
March | 24.22 | 21.57 |
April | 24.39 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.30 | 23.59 |
December | 24.13 | 20.30 |
Annual Sum or Average | 24.31 | 24.51 |
Minimum of Months | 24.08 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.40 | 19.42 |
February | 23.77 | 20.87 |
March | 23.92 | 21.57 |
April | 24.35 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.16 | 23.59 |
December | 23.51 | 20.30 |
Annual Sum or Average | 24.13 | 24.51 |
Minimum of Months | 23.40 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.31 | 19.42 |
February | 23.70 | 20.87 |
March | 23.83 | 21.57 |
April | 24.33 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.13 | 23.59 |
December | 23.47 | 20.30 |
Annual Sum or Average | 24.10 | 24.51 |
Minimum of Months | 23.31 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.31 | 19.42 |
February | 23.70 | 20.87 |
March | 23.83 | 21.57 |
April | 24.33 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.13 | 23.59 |
December | 23.47 | 20.30 |
Annual Sum or Average | 24.10 | 24.51 |
Minimum of Months | 23.31 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.82 | 19.42 |
February | 23.95 | 20.87 |
March | 24.01 | 21.57 |
April | 24.34 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.41 | 28.13 |
August | 24.46 | 27.97 |
September | 24.56 | 27.49 |
October | 24.46 | 26.35 |
November | 24.28 | 23.59 |
December | 23.90 | 20.30 |
Annual Sum or Average | 24.25 | 24.51 |
Minimum of Months | 23.82 | 19.42 |
Maximum of Months | 24.56 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.84 | 19.42 |
February | 23.97 | 20.87 |
March | 24.03 | 21.57 |
April | 24.34 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.44 | 27.97 |
September | 24.53 | 27.49 |
October | 24.45 | 26.35 |
November | 24.28 | 23.59 |
December | 23.92 | 20.30 |
Annual Sum or Average | 24.25 | 24.51 |
Minimum of Months | 23.84 | 19.42 |
Maximum of Months | 24.53 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.84 | 19.42 |
February | 23.48 | 20.87 |
March | 23.76 | 21.57 |
April | 24.90 | 24.11 |
May | 25.76 | 26.41 |
June | 26.62 | 27.68 |
July | 26.99 | 28.13 |
August | 26.83 | 27.97 |
September | 26.73 | 27.49 |
October | 25.80 | 26.35 |
November | 24.60 | 23.59 |
December | 23.18 | 20.30 |
Annual Sum or Average | 25.13 | 24.51 |
Minimum of Months | 22.84 | 19.42 |
Maximum of Months | 26.99 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F2 SW APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.18 | 19.42 |
February | 24.17 | 20.87 |
March | 24.21 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.32 | 23.59 |
December | 24.16 | 20.30 |
Annual Sum or Average | 24.32 | 24.51 |
Minimum of Months | 24.16 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F2 NW APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.83 | 19.42 |
February | 24.00 | 20.87 |
March | 24.08 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.26 | 23.59 |
December | 23.85 | 20.30 |
Annual Sum or Average | 24.23 | 24.51 |
Minimum of Months | 23.83 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F2 SE APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.21 | 19.42 |
February | 24.19 | 20.87 |
March | 24.25 | 21.57 |
April | 24.39 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.41 | 27.49 |
October | 24.41 | 26.35 |
November | 24.33 | 23.59 |
December | 24.18 | 20.30 |
Annual Sum or Average | 24.33 | 24.51 |
Minimum of Months | 24.18 | 19.42 |
Maximum of Months | 24.41 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F2 NE APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.78 | 19.42 |
February | 23.99 | 20.87 |
March | 24.08 | 21.57 |
April | 24.39 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.26 | 23.59 |
December | 23.75 | 20.30 |
Annual Sum or Average | 24.22 | 24.51 |
Minimum of Months | 23.75 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F2 N1 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.76 | 19.42 |
February | 23.98 | 20.87 |
March | 24.04 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.27 | 23.59 |
December | 23.78 | 20.30 |
Annual Sum or Average | 24.22 | 24.51 |
Minimum of Months | 23.76 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F2 N2 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.76 | 19.42 |
February | 23.98 | 20.87 |
March | 24.04 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.27 | 23.59 |
December | 23.77 | 20.30 |
Annual Sum or Average | 24.22 | 24.51 |
Minimum of Months | 23.76 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F2 S1 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.25 | 19.42 |
February | 24.22 | 20.87 |
March | 24.23 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.41 | 28.13 |
August | 24.44 | 27.97 |
September | 24.53 | 27.49 |
October | 24.53 | 26.35 |
November | 24.44 | 23.59 |
December | 24.26 | 20.30 |
Annual Sum or Average | 24.37 | 24.51 |
Minimum of Months | 24.22 | 19.42 |
Maximum of Months | 24.53 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F2 S2 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.25 | 19.42 |
February | 24.23 | 20.87 |
March | 24.23 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.43 | 27.97 |
September | 24.52 | 27.49 |
October | 24.52 | 26.35 |
November | 24.43 | 23.59 |
December | 24.26 | 20.30 |
Annual Sum or Average | 24.37 | 24.51 |
Minimum of Months | 24.23 | 19.42 |
Maximum of Months | 24.52 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F2 CORRIDOR
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 25.15 | 19.42 |
February | 25.36 | 20.87 |
March | 25.56 | 21.57 |
April | 26.12 | 24.11 |
May | 26.37 | 26.41 |
June | 26.64 | 27.68 |
July | 26.75 | 28.13 |
August | 26.66 | 27.97 |
September | 26.70 | 27.49 |
October | 26.42 | 26.35 |
November | 25.91 | 23.59 |
December | 25.23 | 20.30 |
Annual Sum or Average | 26.08 | 24.51 |
Minimum of Months | 25.15 | 19.42 |
Maximum of Months | 26.75 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F3 SW APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.22 | 19.42 |
February | 24.17 | 20.87 |
March | 24.21 | 21.57 |
April | 24.39 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.32 | 23.59 |
December | 24.18 | 20.30 |
Annual Sum or Average | 24.32 | 24.51 |
Minimum of Months | 24.17 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F3 NW APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.89 | 19.42 |
February | 24.02 | 20.87 |
March | 24.09 | 21.57 |
April | 24.39 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.27 | 23.59 |
December | 23.87 | 20.30 |
Annual Sum or Average | 24.24 | 24.51 |
Minimum of Months | 23.87 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F3 SE APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.21 | 19.42 |
February | 24.17 | 20.87 |
March | 24.23 | 21.57 |
April | 24.39 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.42 | 27.49 |
October | 24.42 | 26.35 |
November | 24.35 | 23.59 |
December | 24.17 | 20.30 |
Annual Sum or Average | 24.33 | 24.51 |
Minimum of Months | 24.17 | 19.42 |
Maximum of Months | 24.42 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F3 NE APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.84 | 19.42 |
February | 24.00 | 20.87 |
March | 24.09 | 21.57 |
April | 24.39 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.27 | 23.59 |
December | 23.78 | 20.30 |
Annual Sum or Average | 24.23 | 24.51 |
Minimum of Months | 23.78 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F3 N1 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.85 | 19.42 |
February | 24.01 | 20.87 |
March | 24.06 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.29 | 23.59 |
December | 23.84 | 20.30 |
Annual Sum or Average | 24.24 | 24.51 |
Minimum of Months | 23.84 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F3 N2 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.85 | 19.42 |
February | 24.01 | 20.87 |
March | 24.06 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.29 | 23.59 |
December | 23.83 | 20.30 |
Annual Sum or Average | 24.24 | 24.51 |
Minimum of Months | 23.83 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F3 S1 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.30 | 19.42 |
February | 24.26 | 20.87 |
March | 24.26 | 21.57 |
April | 24.39 | 24.11 |
May | 24.41 | 26.41 |
June | 24.40 | 27.68 |
July | 24.41 | 28.13 |
August | 24.44 | 27.97 |
September | 24.52 | 27.49 |
October | 24.56 | 26.35 |
November | 24.51 | 23.59 |
December | 24.31 | 20.30 |
Annual Sum or Average | 24.40 | 24.51 |
Minimum of Months | 24.26 | 19.42 |
Maximum of Months | 24.56 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F3 S2 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.30 | 19.42 |
February | 24.26 | 20.87 |
March | 24.26 | 21.57 |
April | 24.39 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.43 | 27.97 |
September | 24.52 | 27.49 |
October | 24.55 | 26.35 |
November | 24.51 | 23.59 |
December | 24.31 | 20.30 |
Annual Sum or Average | 24.40 | 24.51 |
Minimum of Months | 24.26 | 19.42 |
Maximum of Months | 24.55 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F3 CORRIDOR
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 25.47 | 19.42 |
February | 25.61 | 20.87 |
March | 25.80 | 21.57 |
April | 26.32 | 24.11 |
May | 26.54 | 26.41 |
June | 26.70 | 27.68 |
July | 26.78 | 28.13 |
August | 26.70 | 27.97 |
September | 26.73 | 27.49 |
October | 26.58 | 26.35 |
November | 26.13 | 23.59 |
December | 25.50 | 20.30 |
Annual Sum or Average | 26.24 | 24.51 |
Minimum of Months | 25.47 | 19.42 |
Maximum of Months | 26.78 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F4 SW APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.22 | 19.42 |
February | 24.17 | 20.87 |
March | 24.20 | 21.57 |
April | 24.39 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.31 | 23.59 |
December | 24.18 | 20.30 |
Annual Sum or Average | 24.32 | 24.51 |
Minimum of Months | 24.17 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F4 NW APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.90 | 19.42 |
February | 24.01 | 20.87 |
March | 24.07 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.26 | 23.59 |
December | 23.87 | 20.30 |
Annual Sum or Average | 24.24 | 24.51 |
Minimum of Months | 23.87 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F4 SE APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.21 | 19.42 |
February | 24.16 | 20.87 |
March | 24.21 | 21.57 |
April | 24.39 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.42 | 27.49 |
October | 24.42 | 26.35 |
November | 24.34 | 23.59 |
December | 24.15 | 20.30 |
Annual Sum or Average | 24.33 | 24.51 |
Minimum of Months | 24.15 | 19.42 |
Maximum of Months | 24.42 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F4 NE APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.85 | 19.42 |
February | 24.00 | 20.87 |
March | 24.07 | 21.57 |
April | 24.39 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.26 | 23.59 |
December | 23.77 | 20.30 |
Annual Sum or Average | 24.23 | 24.51 |
Minimum of Months | 23.77 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F4 N1 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.88 | 19.42 |
February | 24.02 | 20.87 |
March | 24.06 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.28 | 23.59 |
December | 23.85 | 20.30 |
Annual Sum or Average | 24.24 | 24.51 |
Minimum of Months | 23.85 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F4 N2 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.88 | 19.42 |
February | 24.02 | 20.87 |
March | 24.06 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.28 | 23.59 |
December | 23.84 | 20.30 |
Annual Sum or Average | 24.24 | 24.51 |
Minimum of Months | 23.84 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F4 S1 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.31 | 19.42 |
February | 24.25 | 20.87 |
March | 24.25 | 21.57 |
April | 24.39 | 24.11 |
May | 24.41 | 26.41 |
June | 24.40 | 27.68 |
July | 24.41 | 28.13 |
August | 24.43 | 27.97 |
September | 24.51 | 27.49 |
October | 24.55 | 26.35 |
November | 24.51 | 23.59 |
December | 24.31 | 20.30 |
Annual Sum or Average | 24.40 | 24.51 |
Minimum of Months | 24.25 | 19.42 |
Maximum of Months | 24.55 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F4 S2 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.31 | 19.42 |
February | 24.25 | 20.87 |
March | 24.25 | 21.57 |
April | 24.39 | 24.11 |
May | 24.41 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.43 | 27.97 |
September | 24.51 | 27.49 |
October | 24.54 | 26.35 |
November | 24.50 | 23.59 |
December | 24.31 | 20.30 |
Annual Sum or Average | 24.39 | 24.51 |
Minimum of Months | 24.25 | 19.42 |
Maximum of Months | 24.54 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F4 CORRIDOR
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 25.59 | 19.42 |
February | 25.71 | 20.87 |
March | 25.88 | 21.57 |
April | 26.42 | 24.11 |
May | 26.63 | 26.41 |
June | 26.77 | 27.68 |
July | 26.85 | 28.13 |
August | 26.76 | 27.97 |
September | 26.80 | 27.49 |
October | 26.67 | 26.35 |
November | 26.23 | 23.59 |
December | 25.61 | 20.30 |
Annual Sum or Average | 26.33 | 24.51 |
Minimum of Months | 25.59 | 19.42 |
Maximum of Months | 26.85 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.22 | 19.42 |
February | 24.15 | 20.87 |
March | 24.19 | 21.57 |
April | 24.39 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.31 | 23.59 |
December | 24.16 | 20.30 |
Annual Sum or Average | 24.32 | 24.51 |
Minimum of Months | 24.15 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.89 | 19.42 |
February | 24.00 | 20.87 |
March | 24.06 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.25 | 23.59 |
December | 23.85 | 20.30 |
Annual Sum or Average | 24.24 | 24.51 |
Minimum of Months | 23.85 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.20 | 19.42 |
February | 24.14 | 20.87 |
March | 24.19 | 21.57 |
April | 24.39 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.42 | 27.49 |
October | 24.42 | 26.35 |
November | 24.34 | 23.59 |
December | 24.13 | 20.30 |
Annual Sum or Average | 24.32 | 24.51 |
Minimum of Months | 24.13 | 19.42 |
Maximum of Months | 24.42 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.84 | 19.42 |
February | 23.99 | 20.87 |
March | 24.06 | 21.57 |
April | 24.39 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.25 | 23.59 |
December | 23.76 | 20.30 |
Annual Sum or Average | 24.22 | 24.51 |
Minimum of Months | 23.76 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.89 | 19.42 |
February | 24.02 | 20.87 |
March | 24.05 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.28 | 23.59 |
December | 23.84 | 20.30 |
Annual Sum or Average | 24.24 | 24.51 |
Minimum of Months | 23.84 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.88 | 19.42 |
February | 24.02 | 20.87 |
March | 24.05 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.28 | 23.59 |
December | 23.83 | 20.30 |
Annual Sum or Average | 24.24 | 24.51 |
Minimum of Months | 23.83 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.31 | 19.42 |
February | 24.24 | 20.87 |
March | 24.24 | 21.57 |
April | 24.39 | 24.11 |
May | 24.41 | 26.41 |
June | 24.41 | 27.68 |
July | 24.40 | 28.13 |
August | 24.43 | 27.97 |
September | 24.51 | 27.49 |
October | 24.54 | 26.35 |
November | 24.50 | 23.59 |
December | 24.30 | 20.30 |
Annual Sum or Average | 24.39 | 24.51 |
Minimum of Months | 24.24 | 19.42 |
Maximum of Months | 24.54 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.31 | 19.42 |
February | 24.24 | 20.87 |
March | 24.24 | 21.57 |
April | 24.39 | 24.11 |
May | 24.41 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.43 | 27.97 |
September | 24.50 | 27.49 |
October | 24.53 | 26.35 |
November | 24.49 | 23.59 |
December | 24.30 | 20.30 |
Annual Sum or Average | 24.39 | 24.51 |
Minimum of Months | 24.24 | 19.42 |
Maximum of Months | 24.53 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.13 | 19.42 |
February | 26.22 | 20.87 |
March | 26.39 | 21.57 |
April | 26.94 | 24.11 |
May | 27.15 | 26.41 |
June | 27.29 | 27.68 |
July | 27.37 | 28.13 |
August | 27.29 | 27.97 |
September | 27.32 | 27.49 |
October | 27.19 | 26.35 |
November | 26.75 | 23.59 |
December | 26.13 | 20.30 |
Annual Sum or Average | 26.85 | 24.51 |
Minimum of Months | 26.13 | 19.42 |
Maximum of Months | 27.37 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F6 SW APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.19 | 19.42 |
February | 24.12 | 20.87 |
March | 24.16 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.29 | 23.59 |
December | 24.12 | 20.30 |
Annual Sum or Average | 24.31 | 24.51 |
Minimum of Months | 24.12 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F6 NW APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.84 | 19.42 |
February | 23.97 | 20.87 |
March | 24.02 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.23 | 23.59 |
December | 23.79 | 20.30 |
Annual Sum or Average | 24.22 | 24.51 |
Minimum of Months | 23.79 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F6 SE APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.16 | 19.42 |
February | 24.11 | 20.87 |
March | 24.16 | 21.57 |
April | 24.39 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.42 | 27.49 |
October | 24.42 | 26.35 |
November | 24.32 | 23.59 |
December | 24.09 | 20.30 |
Annual Sum or Average | 24.31 | 24.51 |
Minimum of Months | 24.09 | 19.42 |
Maximum of Months | 24.42 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F6 NE APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.78 | 19.42 |
February | 23.95 | 20.87 |
March | 24.02 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.23 | 23.59 |
December | 23.70 | 20.30 |
Annual Sum or Average | 24.20 | 24.51 |
Minimum of Months | 23.70 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F6 N1 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.83 | 19.42 |
February | 23.98 | 20.87 |
March | 24.01 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.26 | 23.59 |
December | 23.78 | 20.30 |
Annual Sum or Average | 24.22 | 24.51 |
Minimum of Months | 23.78 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F6 N2 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.83 | 19.42 |
February | 23.98 | 20.87 |
March | 24.01 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.26 | 23.59 |
December | 23.77 | 20.30 |
Annual Sum or Average | 24.22 | 24.51 |
Minimum of Months | 23.77 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F6 S1 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.28 | 19.42 |
February | 24.21 | 20.87 |
March | 24.21 | 21.57 |
April | 24.39 | 24.11 |
May | 24.41 | 26.41 |
June | 24.41 | 27.68 |
July | 24.40 | 28.13 |
August | 24.43 | 27.97 |
September | 24.50 | 27.49 |
October | 24.53 | 26.35 |
November | 24.48 | 23.59 |
December | 24.26 | 20.30 |
Annual Sum or Average | 24.38 | 24.51 |
Minimum of Months | 24.21 | 19.42 |
Maximum of Months | 24.53 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F6 S2 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.28 | 19.42 |
February | 24.21 | 20.87 |
March | 24.21 | 21.57 |
April | 24.39 | 24.11 |
May | 24.41 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.43 | 27.97 |
September | 24.50 | 27.49 |
October | 24.52 | 26.35 |
November | 24.48 | 23.59 |
December | 24.26 | 20.30 |
Annual Sum or Average | 24.37 | 24.51 |
Minimum of Months | 24.21 | 19.42 |
Maximum of Months | 24.52 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F6 CORRIDOR
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 25.54 | 19.42 |
February | 25.64 | 20.87 |
March | 25.81 | 21.57 |
April | 26.39 | 24.11 |
May | 26.62 | 26.41 |
June | 26.76 | 27.68 |
July | 26.84 | 28.13 |
August | 26.75 | 27.97 |
September | 26.79 | 27.49 |
October | 26.65 | 26.35 |
November | 26.19 | 23.59 |
December | 25.53 | 20.30 |
Annual Sum or Average | 26.29 | 24.51 |
Minimum of Months | 25.53 | 19.42 |
Maximum of Months | 26.84 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F7 SW APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.16 | 19.42 |
February | 24.10 | 20.87 |
March | 24.13 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.29 | 23.59 |
December | 24.09 | 20.30 |
Annual Sum or Average | 24.30 | 24.51 |
Minimum of Months | 24.09 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F7 NW APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.80 | 19.42 |
February | 23.94 | 20.87 |
March | 24.00 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.22 | 23.59 |
December | 23.75 | 20.30 |
Annual Sum or Average | 24.21 | 24.51 |
Minimum of Months | 23.75 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F7 SE APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.14 | 19.42 |
February | 24.09 | 20.87 |
March | 24.14 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.42 | 27.49 |
October | 24.42 | 26.35 |
November | 24.31 | 23.59 |
December | 24.05 | 20.30 |
Annual Sum or Average | 24.30 | 24.51 |
Minimum of Months | 24.05 | 19.42 |
Maximum of Months | 24.42 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F7 NE APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.74 | 19.42 |
February | 23.93 | 20.87 |
March | 23.99 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.22 | 23.59 |
December | 23.65 | 20.30 |
Annual Sum or Average | 24.19 | 24.51 |
Minimum of Months | 23.65 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F7 N1 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.79 | 19.42 |
February | 23.96 | 20.87 |
March | 23.98 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.25 | 23.59 |
December | 23.73 | 20.30 |
Annual Sum or Average | 24.21 | 24.51 |
Minimum of Months | 23.73 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F7 N2 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.79 | 19.42 |
February | 23.96 | 20.87 |
March | 23.98 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.25 | 23.59 |
December | 23.72 | 20.30 |
Annual Sum or Average | 24.21 | 24.51 |
Minimum of Months | 23.72 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F7 S1 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.26 | 19.42 |
February | 24.18 | 20.87 |
March | 24.19 | 21.57 |
April | 24.39 | 24.11 |
May | 24.41 | 26.41 |
June | 24.41 | 27.68 |
July | 24.40 | 28.13 |
August | 24.43 | 27.97 |
September | 24.50 | 27.49 |
October | 24.52 | 26.35 |
November | 24.47 | 23.59 |
December | 24.23 | 20.30 |
Annual Sum or Average | 24.37 | 24.51 |
Minimum of Months | 24.18 | 19.42 |
Maximum of Months | 24.52 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F7 S2 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.26 | 19.42 |
February | 24.18 | 20.87 |
March | 24.18 | 21.57 |
April | 24.39 | 24.11 |
May | 24.41 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.42 | 27.97 |
September | 24.49 | 27.49 |
October | 24.52 | 26.35 |
November | 24.46 | 23.59 |
December | 24.22 | 20.30 |
Annual Sum or Average | 24.36 | 24.51 |
Minimum of Months | 24.18 | 19.42 |
Maximum of Months | 24.52 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F7 CORRIDOR
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 25.42 | 19.42 |
February | 25.52 | 20.87 |
March | 25.70 | 21.57 |
April | 26.31 | 24.11 |
May | 26.55 | 26.41 |
June | 26.69 | 27.68 |
July | 26.77 | 28.13 |
August | 26.68 | 27.97 |
September | 26.72 | 27.49 |
October | 26.58 | 26.35 |
November | 26.10 | 23.59 |
December | 25.41 | 20.30 |
Annual Sum or Average | 26.21 | 24.51 |
Minimum of Months | 25.41 | 19.42 |
Maximum of Months | 26.77 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F8 SW APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.14 | 19.42 |
February | 24.08 | 20.87 |
March | 24.11 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.28 | 23.59 |
December | 24.06 | 20.30 |
Annual Sum or Average | 24.29 | 24.51 |
Minimum of Months | 24.06 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F8 NW APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.76 | 19.42 |
February | 23.92 | 20.87 |
March | 23.98 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.21 | 23.59 |
December | 23.72 | 20.30 |
Annual Sum or Average | 24.20 | 24.51 |
Minimum of Months | 23.72 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F8 SE APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.11 | 19.42 |
February | 24.07 | 20.87 |
March | 24.12 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.42 | 27.49 |
October | 24.42 | 26.35 |
November | 24.30 | 23.59 |
December | 24.02 | 20.30 |
Annual Sum or Average | 24.29 | 24.51 |
Minimum of Months | 24.02 | 19.42 |
Maximum of Months | 24.42 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F8 NE APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.70 | 19.42 |
February | 23.91 | 20.87 |
March | 23.97 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.21 | 23.59 |
December | 23.62 | 20.30 |
Annual Sum or Average | 24.18 | 24.51 |
Minimum of Months | 23.62 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F8 N1 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.76 | 19.42 |
February | 23.94 | 20.87 |
March | 23.96 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.24 | 23.59 |
December | 23.70 | 20.30 |
Annual Sum or Average | 24.20 | 24.51 |
Minimum of Months | 23.70 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F8 N2 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.75 | 19.42 |
February | 23.94 | 20.87 |
March | 23.96 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.24 | 23.59 |
December | 23.69 | 20.30 |
Annual Sum or Average | 24.20 | 24.51 |
Minimum of Months | 23.69 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F8 S1 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.24 | 19.42 |
February | 24.16 | 20.87 |
March | 24.16 | 21.57 |
April | 24.39 | 24.11 |
May | 24.41 | 26.41 |
June | 24.41 | 27.68 |
July | 24.40 | 28.13 |
August | 24.43 | 27.97 |
September | 24.49 | 27.49 |
October | 24.51 | 26.35 |
November | 24.45 | 23.59 |
December | 24.20 | 20.30 |
Annual Sum or Average | 24.35 | 24.51 |
Minimum of Months | 24.16 | 19.42 |
Maximum of Months | 24.51 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F8 S2 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.24 | 19.42 |
February | 24.16 | 20.87 |
March | 24.16 | 21.57 |
April | 24.39 | 24.11 |
May | 24.41 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.42 | 27.97 |
September | 24.49 | 27.49 |
October | 24.51 | 26.35 |
November | 24.45 | 23.59 |
December | 24.19 | 20.30 |
Annual Sum or Average | 24.35 | 24.51 |
Minimum of Months | 24.16 | 19.42 |
Maximum of Months | 24.51 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F8 CORRIDOR
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 25.36 | 19.42 |
February | 25.48 | 20.87 |
March | 25.66 | 21.57 |
April | 26.30 | 24.11 |
May | 26.55 | 26.41 |
June | 26.70 | 27.68 |
July | 26.78 | 28.13 |
August | 26.69 | 27.97 |
September | 26.72 | 27.49 |
October | 26.58 | 26.35 |
November | 26.07 | 23.59 |
December | 25.36 | 20.30 |
Annual Sum or Average | 26.19 | 24.51 |
Minimum of Months | 25.36 | 19.42 |
Maximum of Months | 26.78 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F9 SW APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.10 | 19.42 |
February | 24.06 | 20.87 |
March | 24.09 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.26 | 23.59 |
December | 24.03 | 20.30 |
Annual Sum or Average | 24.28 | 24.51 |
Minimum of Months | 24.03 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F9 NW APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.73 | 19.42 |
February | 23.91 | 20.87 |
March | 23.96 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.20 | 23.59 |
December | 23.69 | 20.30 |
Annual Sum or Average | 24.19 | 24.51 |
Minimum of Months | 23.69 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F9 SE APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.07 | 19.42 |
February | 24.04 | 20.87 |
March | 24.10 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.42 | 27.49 |
October | 24.41 | 26.35 |
November | 24.29 | 23.59 |
December | 23.98 | 20.30 |
Annual Sum or Average | 24.28 | 24.51 |
Minimum of Months | 23.98 | 19.42 |
Maximum of Months | 24.42 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F9 NE APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.66 | 19.42 |
February | 23.89 | 20.87 |
March | 23.95 | 21.57 |
April | 24.38 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.20 | 23.59 |
December | 23.59 | 20.30 |
Annual Sum or Average | 24.17 | 24.51 |
Minimum of Months | 23.59 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F9 N1 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.72 | 19.42 |
February | 23.92 | 20.87 |
March | 23.95 | 21.57 |
April | 24.37 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.22 | 23.59 |
December | 23.66 | 20.30 |
Annual Sum or Average | 24.19 | 24.51 |
Minimum of Months | 23.66 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F9 N2 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.71 | 19.42 |
February | 23.92 | 20.87 |
March | 23.95 | 21.57 |
April | 24.37 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.22 | 23.59 |
December | 23.66 | 20.30 |
Annual Sum or Average | 24.19 | 24.51 |
Minimum of Months | 23.66 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F9 S1 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.20 | 19.42 |
February | 24.13 | 20.87 |
March | 24.14 | 21.57 |
April | 24.38 | 24.11 |
May | 24.41 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.42 | 27.97 |
September | 24.47 | 27.49 |
October | 24.49 | 26.35 |
November | 24.42 | 23.59 |
December | 24.15 | 20.30 |
Annual Sum or Average | 24.34 | 24.51 |
Minimum of Months | 24.13 | 19.42 |
Maximum of Months | 24.49 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F9 S2 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.20 | 19.42 |
February | 24.13 | 20.87 |
March | 24.14 | 21.57 |
April | 24.38 | 24.11 |
May | 24.41 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.42 | 27.97 |
September | 24.48 | 27.49 |
October | 24.49 | 26.35 |
November | 24.43 | 23.59 |
December | 24.15 | 20.30 |
Annual Sum or Average | 24.34 | 24.51 |
Minimum of Months | 24.13 | 19.42 |
Maximum of Months | 24.49 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: F9 CORRIDOR
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 25.33 | 19.42 |
February | 25.47 | 20.87 |
March | 25.68 | 21.57 |
April | 26.37 | 24.11 |
May | 26.64 | 26.41 |
June | 26.80 | 27.68 |
July | 26.90 | 28.13 |
August | 26.79 | 27.97 |
September | 26.81 | 27.49 |
October | 26.65 | 26.35 |
November | 26.10 | 23.59 |
December | 25.34 | 20.30 |
Annual Sum or Average | 26.24 | 24.51 |
Minimum of Months | 25.33 | 19.42 |
Maximum of Months | 26.90 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.89 | 19.42 |
February | 23.95 | 20.87 |
March | 24.02 | 21.57 |
April | 24.36 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.21 | 23.59 |
December | 23.90 | 20.30 |
Annual Sum or Average | 24.23 | 24.51 |
Minimum of Months | 23.89 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.58 | 19.42 |
February | 23.81 | 20.87 |
March | 23.92 | 21.57 |
April | 24.36 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.16 | 23.59 |
December | 23.64 | 20.30 |
Annual Sum or Average | 24.15 | 24.51 |
Minimum of Months | 23.58 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.85 | 19.42 |
February | 23.92 | 20.87 |
March | 24.03 | 21.57 |
April | 24.36 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.41 | 27.49 |
October | 24.41 | 26.35 |
November | 24.23 | 23.59 |
December | 23.86 | 20.30 |
Annual Sum or Average | 24.22 | 24.51 |
Minimum of Months | 23.85 | 19.42 |
Maximum of Months | 24.41 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.53 | 19.42 |
February | 23.79 | 20.87 |
March | 23.91 | 21.57 |
April | 24.36 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.16 | 23.59 |
December | 23.55 | 20.30 |
Annual Sum or Average | 24.14 | 24.51 |
Minimum of Months | 23.53 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.57 | 19.42 |
February | 23.82 | 20.87 |
March | 23.90 | 21.57 |
April | 24.36 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.17 | 23.59 |
December | 23.60 | 20.30 |
Annual Sum or Average | 24.15 | 24.51 |
Minimum of Months | 23.57 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.57 | 19.42 |
February | 23.82 | 20.87 |
March | 23.90 | 21.57 |
April | 24.36 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.40 | 27.49 |
October | 24.40 | 26.35 |
November | 24.17 | 23.59 |
December | 23.59 | 20.30 |
Annual Sum or Average | 24.15 | 24.51 |
Minimum of Months | 23.57 | 19.42 |
Maximum of Months | 24.40 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.00 | 19.42 |
February | 24.02 | 20.87 |
March | 24.05 | 21.57 |
April | 24.36 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.43 | 27.49 |
October | 24.43 | 26.35 |
November | 24.30 | 23.59 |
December | 23.99 | 20.30 |
Annual Sum or Average | 24.27 | 24.51 |
Minimum of Months | 23.99 | 19.42 |
Maximum of Months | 24.43 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.99 | 19.42 |
February | 24.02 | 20.87 |
March | 24.05 | 21.57 |
April | 24.36 | 24.11 |
May | 24.40 | 26.41 |
June | 24.40 | 27.68 |
July | 24.40 | 28.13 |
August | 24.40 | 27.97 |
September | 24.43 | 27.49 |
October | 24.44 | 26.35 |
November | 24.31 | 23.59 |
December | 23.98 | 20.30 |
Annual Sum or Average | 24.27 | 24.51 |
Minimum of Months | 23.98 | 19.42 |
Maximum of Months | 24.44 | 28.13 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2015-09-09 19:12:00
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 25.77 | 19.42 |
February | 26.05 | 20.87 |
March | 26.33 | 21.57 |
April | 27.15 | 24.11 |
May | 27.52 | 26.41 |
June | 27.74 | 27.68 |
July | 27.88 | 28.13 |
August | 27.70 | 27.97 |
September | 27.71 | 27.49 |
October | 27.44 | 26.35 |
November | 26.76 | 23.59 |
December | 25.87 | 20.30 |
Annual Sum or Average | 27.00 | 24.51 |
Minimum of Months | 25.77 | 19.42 |
Maximum of Months | 27.88 | 28.13 |
Report: COMPONENTS OF PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2015-09-09 19:12:00
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W] | |
January | 0.254114E+12 | 163501.228 | 01-JAN-17:45 | 11327.174 | 57042.023 | 20633.287 | 0.000 | 56672.508 | 10364.000 | 2580.935 | 2893.490 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
February | 0.244328E+12 | 187414.813 | 11-FEB-18:15 | 13120.457 | 57042.023 | 20633.287 | 0.000 | 78137.284 | 10364.000 | 2580.935 | 3549.016 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
March | 0.284553E+12 | 180493.085 | 28-MAR-16:15 | 11327.174 | 57142.088 | 20633.287 | 0.000 | 83531.517 | 0.000 | 2580.935 | 3282.888 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
April | 0.308116E+12 | 181958.946 | 13-APR-18:45 | 14401.373 | 51749.961 | 20633.287 | 0.000 | 77000.809 | 10364.000 | 2580.935 | 3467.556 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
May | 0.358461E+12 | 186891.722 | 29-MAY-17:15 | 13120.457 | 57042.023 | 20633.287 | 0.000 | 87751.474 | 0.000 | 2580.935 | 3775.735 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
June | 0.364274E+12 | 189609.733 | 26-JUN-17:30 | 13120.457 | 57042.023 | 20633.287 | 0.000 | 90399.348 | 0.000 | 2580.935 | 3845.675 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
July | 0.377008E+12 | 189317.954 | 27-JUL-17:30 | 13120.457 | 57042.023 | 20633.287 | 0.000 | 90107.569 | 0.000 | 2580.935 | 3845.675 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.376337E+12 | 186495.844 | 16-AUG-16:15 | 11327.174 | 57142.088 | 20633.287 | 0.000 | 88971.490 | 0.000 | 2580.935 | 3845.675 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.363678E+12 | 187642.744 | 18-SEP-18:30 | 14401.373 | 51749.961 | 20633.287 | 0.000 | 82306.488 | 10364.000 | 2580.935 | 3845.675 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
October | 0.360581E+12 | 182992.198 | 03-OCT-16:30 | 11327.174 | 57142.088 | 20633.287 | 0.000 | 85467.881 | 0.000 | 2580.935 | 3845.675 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
November | 0.310467E+12 | 190419.011 | 29-NOV-18:30 | 13120.457 | 57042.023 | 20633.287 | 0.000 | 80892.513 | 10364.000 | 2580.935 | 3797.788 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
December | 0.268631E+12 | 180299.237 | 08-DEC-17:30 | 11327.174 | 57142.088 | 20633.287 | 0.000 | 72895.303 | 10364.000 | 2580.935 | 3361.291 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.387055E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||||
Minimum of Months | 0.244328E+12 | 163501.228 | 11327.174 | 51749.961 | 20633.287 | 0.000 | 56672.508 | 0.000 | 2580.935 | 2893.490 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.377008E+12 | 190419.011 | 14401.373 | 57142.088 | 20633.287 | 0.000 | 90399.348 | 10364.000 | 2580.935 | 3845.675 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: COMPONENTS OF PEAK GAS DEMAND
For: Meter
Timestamp: 2015-09-09 19:12:00
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC [Invalid/Undefined] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT {AT MAX/MIN} [W] | WATERSYSTEMS:GAS {AT MAX/MIN} [W] | WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.749307E+11 | 70351.581 | 18-JAN-07:00 | 0.000 | 0.000 | 0.000 | 70351.581 | 70351.581 | 70351.581 | 0.000 |
February | 0.695859E+11 | 143064.745 | 04-FEB-07:15 | 0.000 | 0.000 | 0.000 | 143064.745 | 69627.488 | 69627.488 | 73437.258 |
March | 0.724998E+11 | 103425.035 | 16-MAR-06:30 | 0.000 | 0.000 | 0.000 | 103425.035 | 69459.901 | 69459.901 | 33965.135 |
April | 0.670846E+11 | 69164.211 | 01-APR-06:00 | 0.000 | 0.000 | 0.000 | 69164.211 | 69164.211 | 69164.211 | 0.000 |
May | 0.662221E+11 | 68289.198 | 02-MAY-06:00 | 0.000 | 0.000 | 0.000 | 68289.198 | 68289.198 | 68289.198 | 0.000 |
June | 0.618138E+11 | 67522.640 | 01-JUN-06:45 | 0.000 | 0.000 | 0.000 | 67522.640 | 67522.640 | 67522.640 | 0.000 |
July | 0.628685E+11 | 67100.724 | 01-JUL-06:00 | 0.000 | 0.000 | 0.000 | 67100.724 | 67100.724 | 67100.724 | 0.000 |
August | 0.634900E+11 | 67369.016 | 29-AUG-06:45 | 0.000 | 0.000 | 0.000 | 67369.016 | 67369.016 | 67369.016 | 0.000 |
September | 0.634782E+11 | 68009.371 | 27-SEP-06:45 | 0.000 | 0.000 | 0.000 | 68009.371 | 68009.371 | 68009.371 | 0.000 |
October | 0.685629E+11 | 68987.837 | 31-OCT-06:00 | 0.000 | 0.000 | 0.000 | 68987.837 | 68987.837 | 68987.837 | 0.000 |
November | 0.693362E+11 | 69734.549 | 30-NOV-07:45 | 0.000 | 0.000 | 0.000 | 69734.549 | 69734.549 | 69734.549 | 0.000 |
December | 0.739889E+11 | 70246.762 | 31-DEC-07:45 | 0.000 | 0.000 | 0.000 | 70246.762 | 70246.762 | 70246.762 | 0.000 |
Annual Sum or Average | 0.813862E+12 | 0.000 | 0.000 | 0.000 | ||||||
Minimum of Months | 0.618138E+11 | 67100.724 | 0.000 | 0.000 | 0.000 | 67100.724 | 67100.724 | 67100.724 | 0.000 | |
Maximum of Months | 0.749307E+11 | 143064.745 | 0.000 | 0.000 | 0.000 | 143064.745 | 70351.581 | 70351.581 | 73437.258 |