Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:59

Tabular Output Report in Format: HTML

Building: High-Rise Apartment

Environment: Fairbanks Intl Arpt AK USA TMY3 WMO#=702610

Simulation Timestamp: 2015-09-09 19:00:31


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 6975.30 890.11 988.02
Net Site Energy 6975.30 890.11 988.02
Total Source Energy 14138.33 1804.17 2002.63
Net Source Energy 14138.33 1804.17 2002.63


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 7836.48
Net Conditioned Building Area 7059.89
Unconditioned Building Area 776.58


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 673.86 2349.92 0.00 0.00 0.00 0.00
Cooling 123.96 0.00 0.00 0.00 0.00 0.00
Interior Lighting 296.56 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 161.58 0.00 0.00 0.00 0.00 0.00
Interior Equipment 1137.32 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 668.13 0.00 0.00 0.00 0.00 0.00
Pumps 55.17 0.00 0.00 0.00 0.00 0.00
Heat Rejection 4.75 0.00 0.00 0.00 0.00 426.74
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 1467.86 0.00 0.00 0.00 4778.51
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 3157.51 3817.79 0.00 0.00 0.00 5205.26
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating Boiler 0.00 2349.92 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
  Other 673.86 0.00 0.00 0.00 0.00 0.00
Cooling General 123.96 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 242.55 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 54.01 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 161.58 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 1137.32 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 668.13 0.00 0.00 0.00 0.00 0.00
Pumps General 55.17 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 4.75 0.00 0.00 0.00 0.00 426.74
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 1467.86 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 4778.51
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 64.89 0.00 0.00 0.00 0.00 0.00
HVAC 216.13 540.77 0.00 0.00 0.00 0.74
Other 161.10 0.00 0.00 0.00 0.00 0.00
Total 447.25 540.77 0.00 0.00 0.00 0.74


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 58.46 0.00 0.00 0.00 0.00 0.00
HVAC 194.71 487.18 0.00 0.00 0.00 0.66
Other 145.13 0.00 0.00 0.00 0.00 0.00
Total 402.93 487.18 0.00 0.00 0.00 0.66


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 3157.51 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 3157.51 100.00
     
Total On-Site and Utility Electric Sources 3157.51 100.00
Total Electricity End Uses 3157.51 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 5205.26 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 5205.26 100.00
Total Water End Uses 5205.26 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 115.25
Time Setpoint Not Met During Occupied Cooling 28.25
Time Not Comfortable Based on Simple ASHRAE 55-2004 4220.50


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |

COMPONENTS OF PEAK ELECTRICAL DEMAND

| Meter |

COMPONENTS OF PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:59
RunPeriod Fairbanks Intl Arpt AK USA TMY3 WMO#=702610
Weather File Fairbanks Intl Arpt AK USA TMY3 WMO#=702610
Latitude [deg] 64.82
Longitude [deg] -147.8
Elevation [m] 133.00
Time Zone -9.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3855.02 1411.96 515.55 1411.96 515.55
Window Opening Area [m2] 1150.39 423.59 152.73 423.59 150.48
Window-Wall Ratio [%] 29.84 30.00 29.62 30.00 29.19


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3752.84 1411.96 464.46 1411.96 464.46
Window Opening Area [m2] 1125.85 423.59 139.34 423.59 139.34
Window-Wall Ratio [%] 30.00 30.00 30.00 30.00 30.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
OFFICE 88.25 Yes Yes 268.96 1.00 58.52 17.56 29.5362 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 4.47 6.7128   0.0000
F2 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F3 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F4 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
M SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
M CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 13.4255   0.0000
F6 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F7 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F8 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F9 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
T SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   264.3872
Total 7836.48     23884.04   3855.02 1150.39 4.3335 39.48 8.6291
Conditioned Total 7059.89     21517.16   3752.84 1125.85 3.9979 35.57 6.6700
Unconditioned Total 776.58     2366.87   102.18 24.54 7.3840   26.4387
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 28-JAN-23:00 29-JAN-07:00 - - - 29-JUL-17:15
Heating 261078.47 254312.63 0.00 0.00 0.00 0.00
Cooling 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 7484.42 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 10364.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 29363.65 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 21186.30 0.00 0.00 0.00 0.00 0.00
Pumps 1756.43 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 89941.37 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 332168.45 344253.99 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating Boiler 0.00 254312.63 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 6390.84 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 1093.58 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 10364.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 29363.65 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 21186.30 0.00 0.00 0.00 0.00 0.00
Pumps General 1756.43 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 89941.37 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 2134.12 2547.32 0.00 0.00 0.00
Cooling 392.59 0.00 0.00 0.00 0.00
Interior Lighting 939.20 0.00 0.00 0.00 0.00
Exterior Lighting 511.73 0.00 0.00 0.00 0.00
Interior Equipment 3601.91 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 2115.97 0.00 0.00 0.00 0.00
Pumps 174.73 0.00 0.00 0.00 0.00
Heat Rejection 15.04 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 1591.16 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 9999.85 4138.48 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 302.29 360.82 0.00 0.00 0.00
Cooling 55.61 0.00 0.00 0.00 0.00
Interior Lighting 133.03 0.00 0.00 0.00 0.00
Exterior Lighting 72.48 0.00 0.00 0.00 0.00
Interior Equipment 510.19 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 299.72 0.00 0.00 0.00 0.00
Pumps 24.75 0.00 0.00 0.00 0.00
Heat Rejection 2.13 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 225.38 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1416.43 586.20 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 302.29 360.82 0.00 0.00 0.00
Cooling 55.61 0.00 0.00 0.00 0.00
Interior Lighting 133.03 0.00 0.00 0.00 0.00
Exterior Lighting 72.48 0.00 0.00 0.00 0.00
Interior Equipment 510.19 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 299.72 0.00 0.00 0.00 0.00
Pumps 24.75 0.00 0.00 0.00 0.00
Heat Rejection 2.13 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 225.38 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1416.43 586.20 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB -41.90 0.00 -41.90 Wetbulb [C] 0.30 20.00
FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 27.40 10.20 16.10 Wetbulb [C] 3.10 180.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G WWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 270.00 180.00  
F2 WWALL SWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
F2 SWALL SWA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F2 NWALL NWA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F2 WWALL NWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
F2 EWALL SEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
F2 SWALL SEA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F2 NWALL NEA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F2 EWALL NEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
F2 NWALL N1A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F2 NWALL N2A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F2 SWALL S1A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F2 SWALL S2A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F2 WWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 270.00 90.00 W
F2 EWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 90.00 90.00 E
F3 WWALL SWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
F3 SWALL SWA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F3 NWALL NWA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F3 WWALL NWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
F3 EWALL SEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
F3 SWALL SEA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F3 NWALL NEA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F3 EWALL NEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
F3 NWALL N1A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F3 NWALL N2A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F3 SWALL S1A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F3 SWALL S2A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F3 WWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 270.00 90.00 W
F3 EWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 90.00 90.00 E
F4 WWALL SWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
F4 SWALL SWA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F4 NWALL NWA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F4 WWALL NWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
F4 EWALL SEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
F4 SWALL SEA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F4 NWALL NEA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F4 EWALL NEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
F4 NWALL N1A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F4 NWALL N2A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F4 SWALL S1A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F4 SWALL S2A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F4 WWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 270.00 90.00 W
F4 EWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 90.00 90.00 E
M WWALL SWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
M WWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 90.00 90.00 E
F6 WWALL SWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
F6 SWALL SWA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F6 NWALL NWA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F6 WWALL NWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
F6 EWALL SEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
F6 SWALL SEA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F6 NWALL NEA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F6 EWALL NEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
F6 NWALL N1A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F6 NWALL N2A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F6 SWALL S1A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F6 SWALL S2A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F6 WWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 270.00 90.00 W
F6 EWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 90.00 90.00 E
F7 WWALL SWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
F7 SWALL SWA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F7 NWALL NWA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F7 WWALL NWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
F7 EWALL SEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
F7 SWALL SEA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F7 NWALL NEA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F7 EWALL NEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
F7 NWALL N1A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F7 NWALL N2A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F7 SWALL S1A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F7 SWALL S2A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F7 WWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 270.00 90.00 W
F7 EWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 90.00 90.00 E
F8 WWALL SWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
F8 SWALL SWA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F8 NWALL NWA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F8 WWALL NWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
F8 EWALL SEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
F8 SWALL SEA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F8 NWALL NEA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F8 EWALL NEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
F8 NWALL N1A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F8 NWALL N2A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F8 SWALL S1A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F8 SWALL S2A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F8 WWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 270.00 90.00 W
F8 EWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 90.00 90.00 E
F9 WWALL SWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
F9 SWALL SWA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F9 NWALL NWA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F9 WWALL NWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
F9 EWALL SEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
F9 SWALL SEA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F9 NWALL NEA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F9 EWALL NEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
F9 NWALL N1A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F9 NWALL N2A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
F9 SWALL S1A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F9 SWALL S2A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
F9 WWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 270.00 90.00 W
F9 EWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 90.00 90.00 E
T WWALL SWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.30 0.219 0.228 88.25 0.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.210 0.217 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.30 0.219 0.228 88.25 0.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.30 0.219 0.228 88.25 0.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.210 0.217 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.30 0.219 0.228 88.25 0.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.30 0.219 0.228 88.25 0.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.210 0.217 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.30 0.219 0.228 88.25 0.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.30 0.219 0.228 88.25 0.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.210 0.217 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.30 0.219 0.228 88.25 0.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.210 0.217 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.30 0.219 0.228 77.66 0.00 0.00  


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW3 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No G SWALL SWA 180.00 90.00 S
GWINDOW2 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No G WWALL SWA 270.00 90.00 W
GWINDOW4 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No G NWALL NWA 0.00 90.00 N
GWINDOW6 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No G WWALL NWA 270.00 90.00 W
GWINDOW1 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No G SWALL SEA 180.00 90.00 S
GWINDOW8 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No G EWALL SEA 90.00 90.00 E
GWINDOW5 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No G NWALL NEA 0.00 90.00 N
GWINDOW7 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No G EWALL NEA 90.00 90.00 E
GWINDOW9 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No G NWALL N1A 0.00 90.00 N
GWINDOW10 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No G NWALL N2A 0.00 90.00 N
GWINDOW11 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No G SWALL S1A 180.00 90.00 S
GWINDOW12 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No G SWALL S2A 180.00 90.00 S
GWINDOW13 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No G WWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.42_SHGC_0.45 3.36 0.00 0.00 3.36 3.36 2.493 0.426 0.308     No G EWALL C 90.00 90.00 E
F2WINDOW2 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F2 WWALL SWA 270.00 90.00 W
F2WINDOW3 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F2 SWALL SWA 180.00 90.00 S
F2WINDOW4 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F2 NWALL NWA 0.00 90.00 N
F2WINDOW6 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F2 WWALL NWA 270.00 90.00 W
F2WINDOW8 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F2 EWALL SEA 90.00 90.00 E
F2WINDOW1 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F2 SWALL SEA 180.00 90.00 S
F2WINDOW5 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F2 NWALL NEA 0.00 90.00 N
F2WINDOW7 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F2 EWALL NEA 90.00 90.00 E
F2WINDOW9 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F2 NWALL N1A 0.00 90.00 N
F2WINDOW10 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F2 NWALL N2A 0.00 90.00 N
F2WINDOW11 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F2 SWALL S1A 180.00 90.00 S
F2WINDOW12 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F2 SWALL S2A 180.00 90.00 S
F2WINDOW13 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F2 WWALL C 270.00 90.00 W
F2WINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F2 EWALL C 90.00 90.00 E
F3WINDOW2 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F3 WWALL SWA 270.00 90.00 W
F3WINDOW3 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F3 SWALL SWA 180.00 90.00 S
F3WINDOW4 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F3 NWALL NWA 0.00 90.00 N
F3WINDOW6 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F3 WWALL NWA 270.00 90.00 W
F3WINDOW8 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F3 EWALL SEA 90.00 90.00 E
F3WINDOW1 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F3 SWALL SEA 180.00 90.00 S
F3WINDOW5 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F3 NWALL NEA 0.00 90.00 N
F3WINDOW7 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F3 EWALL NEA 90.00 90.00 E
F3WINDOW9 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F3 NWALL N1A 0.00 90.00 N
F3WINDOW10 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F3 NWALL N2A 0.00 90.00 N
F3WINDOW11 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F3 SWALL S1A 180.00 90.00 S
F3WINDOW12 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F3 SWALL S2A 180.00 90.00 S
F3WINDOW13 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F3 WWALL C 270.00 90.00 W
F3WINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F3 EWALL C 90.00 90.00 E
F4WINDOW2 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F4 WWALL SWA 270.00 90.00 W
F4WINDOW3 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F4 SWALL SWA 180.00 90.00 S
F4WINDOW4 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F4 NWALL NWA 0.00 90.00 N
F4WINDOW6 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F4 WWALL NWA 270.00 90.00 W
F4WINDOW8 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F4 EWALL SEA 90.00 90.00 E
F4WINDOW1 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F4 SWALL SEA 180.00 90.00 S
F4WINDOW5 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F4 NWALL NEA 0.00 90.00 N
F4WINDOW7 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F4 EWALL NEA 90.00 90.00 E
F4WINDOW9 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F4 NWALL N1A 0.00 90.00 N
F4WINDOW10 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F4 NWALL N2A 0.00 90.00 N
F4WINDOW11 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F4 SWALL S1A 180.00 90.00 S
F4WINDOW12 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F4 SWALL S2A 180.00 90.00 S
F4WINDOW13 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F4 WWALL C 270.00 90.00 W
F4WINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F4 EWALL C 90.00 90.00 E
MWINDOW2 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No M WWALL SWA 270.00 90.00 W
MWINDOW3 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No M SWALL SWA 180.00 90.00 S
MWINDOW4 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No M NWALL NWA 0.00 90.00 N
MWINDOW6 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No M WWALL NWA 270.00 90.00 W
MWINDOW8 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No M EWALL SEA 90.00 90.00 E
MWINDOW1 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No M SWALL SEA 180.00 90.00 S
MWINDOW5 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No M NWALL NEA 0.00 90.00 N
MWINDOW7 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No M EWALL NEA 90.00 90.00 E
MWINDOW9 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No M NWALL N1A 0.00 90.00 N
MWINDOW10 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No M NWALL N2A 0.00 90.00 N
MWINDOW11 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No M SWALL S1A 180.00 90.00 S
MWINDOW12 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No M SWALL S2A 180.00 90.00 S
MWINDOW13 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No M WWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No M EWALL C 90.00 90.00 E
F6WINDOW2 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F6 WWALL SWA 270.00 90.00 W
F6WINDOW3 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F6 SWALL SWA 180.00 90.00 S
F6WINDOW4 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F6 NWALL NWA 0.00 90.00 N
F6WINDOW6 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F6 WWALL NWA 270.00 90.00 W
F6WINDOW8 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F6 EWALL SEA 90.00 90.00 E
F6WINDOW1 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F6 SWALL SEA 180.00 90.00 S
F6WINDOW5 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F6 NWALL NEA 0.00 90.00 N
F6WINDOW7 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F6 EWALL NEA 90.00 90.00 E
F6WINDOW9 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F6 NWALL N1A 0.00 90.00 N
F6WINDOW10 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F6 NWALL N2A 0.00 90.00 N
F6WINDOW11 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F6 SWALL S1A 180.00 90.00 S
F6WINDOW12 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F6 SWALL S2A 180.00 90.00 S
F6WINDOW13 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F6 WWALL C 270.00 90.00 W
F6WINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F6 EWALL C 90.00 90.00 E
F7WINDOW2 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F7 WWALL SWA 270.00 90.00 W
F7WINDOW3 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F7 SWALL SWA 180.00 90.00 S
F7WINDOW4 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F7 NWALL NWA 0.00 90.00 N
F7WINDOW6 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F7 WWALL NWA 270.00 90.00 W
F7WINDOW8 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F7 EWALL SEA 90.00 90.00 E
F7WINDOW1 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F7 SWALL SEA 180.00 90.00 S
F7WINDOW5 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F7 NWALL NEA 0.00 90.00 N
F7WINDOW7 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F7 EWALL NEA 90.00 90.00 E
F7WINDOW9 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F7 NWALL N1A 0.00 90.00 N
F7WINDOW10 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F7 NWALL N2A 0.00 90.00 N
F7WINDOW11 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F7 SWALL S1A 180.00 90.00 S
F7WINDOW12 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F7 SWALL S2A 180.00 90.00 S
F7WINDOW13 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F7 WWALL C 270.00 90.00 W
F7WINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F7 EWALL C 90.00 90.00 E
F8WINDOW2 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F8 WWALL SWA 270.00 90.00 W
F8WINDOW3 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F8 SWALL SWA 180.00 90.00 S
F8WINDOW4 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F8 NWALL NWA 0.00 90.00 N
F8WINDOW6 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F8 WWALL NWA 270.00 90.00 W
F8WINDOW8 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F8 EWALL SEA 90.00 90.00 E
F8WINDOW1 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F8 SWALL SEA 180.00 90.00 S
F8WINDOW5 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F8 NWALL NEA 0.00 90.00 N
F8WINDOW7 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F8 EWALL NEA 90.00 90.00 E
F8WINDOW9 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F8 NWALL N1A 0.00 90.00 N
F8WINDOW10 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F8 NWALL N2A 0.00 90.00 N
F8WINDOW11 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F8 SWALL S1A 180.00 90.00 S
F8WINDOW12 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F8 SWALL S2A 180.00 90.00 S
F8WINDOW13 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F8 WWALL C 270.00 90.00 W
F8WINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F8 EWALL C 90.00 90.00 E
F9WINDOW2 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F9 WWALL SWA 270.00 90.00 W
F9WINDOW3 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F9 SWALL SWA 180.00 90.00 S
F9WINDOW4 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F9 NWALL NWA 0.00 90.00 N
F9WINDOW6 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F9 WWALL NWA 270.00 90.00 W
F9WINDOW8 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F9 EWALL SEA 90.00 90.00 E
F9WINDOW1 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F9 SWALL SEA 180.00 90.00 S
F9WINDOW5 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F9 NWALL NEA 0.00 90.00 N
F9WINDOW7 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No F9 EWALL NEA 90.00 90.00 E
F9WINDOW9 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F9 NWALL N1A 0.00 90.00 N
F9WINDOW10 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F9 NWALL N2A 0.00 90.00 N
F9WINDOW11 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F9 SWALL S1A 180.00 90.00 S
F9WINDOW12 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No F9 SWALL S2A 180.00 90.00 S
F9WINDOW13 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F9 WWALL C 270.00 90.00 W
F9WINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No F9 EWALL C 90.00 90.00 E
TWINDOW2 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No T WWALL SWA 270.00 90.00 W
TWINDOW3 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No T SWALL SWA 180.00 90.00 S
TWINDOW4 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No T NWALL NWA 0.00 90.00 N
TWINDOW6 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No T WWALL NWA 270.00 90.00 W
TWINDOW8 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No T EWALL SEA 90.00 90.00 E
TWINDOW1 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No T SWALL SEA 180.00 90.00 S
TWINDOW5 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No T NWALL NEA 0.00 90.00 N
TWINDOW7 WINDOW_U_0.42_SHGC_0.45 6.97 0.00 0.00 6.97 6.97 2.493 0.426 0.308     No T EWALL NEA 90.00 90.00 E
TWINDOW9 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No T NWALL N1A 0.00 90.00 N
TWINDOW10 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No T NWALL N2A 0.00 90.00 N
TWINDOW11 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No T SWALL S1A 180.00 90.00 S
TWINDOW12 WINDOW_U_0.42_SHGC_0.45 10.59 0.00 0.00 10.59 10.59 2.493 0.426 0.308     No T SWALL S2A 180.00 90.00 S
TWINDOW13 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No T WWALL C 270.00 90.00 W
TWINDOW14 WINDOW_U_0.42_SHGC_0.45 1.11 0.00 0.00 1.11 1.11 2.493 0.426 0.308     No T EWALL C 90.00 90.00 E
Total or Average           1150.39 2.493 0.426 0.308              
North Total or Average           423.59 2.493 0.426 0.308              
Non-North Total or Average           726.80 2.493 0.426 0.308              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
GWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
GWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
GWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
GWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
GWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
GWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
GWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
GWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
F2WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
F2WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F2WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
F2WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
F2WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F2WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
F2WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F2WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F2WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
F2WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
F3WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
F3WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F3WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
F3WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
F3WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F3WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
F3WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F3WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F3WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
F3WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
F4WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
F4WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F4WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
F4WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
F4WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F4WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
F4WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F4WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F4WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
F4WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
MWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
MWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
MWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
MWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
MWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
MWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
MWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
MWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
MWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
F6WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
F6WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F6WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
F6WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
F6WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F6WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
F6WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F6WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F6WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
F6WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
F7WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
F7WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F7WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
F7WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
F7WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F7WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
F7WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F7WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F7WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
F7WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
F8WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
F8WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F8WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
F8WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
F8WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F8WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
F8WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F8WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F8WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
F8WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
F9WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
F9WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F9WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
F9WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
F9WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F9WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
F9WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F9WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
F9WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
F9WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
TWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
TWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
TWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
TWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
TWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
TWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00
TWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
TWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 0.00 1.00 0.00
TWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 0.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 0.00 1.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
G SW APARTMENT_LIGHTS_HARDWIRED G SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G NW APARTMENT_LIGHTS_HARDWIRED G NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
OFFICE_LIGHTS_HARDWIRED OFFICE 14.7681 88.25 1303.26 GeneralLights LTG_OFF_SCH 62.05 168.00 61.07 0.0000 Y 14.94
G NE APARTMENT_LIGHTS_HARDWIRED G NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G N1 APARTMENT_LIGHTS_HARDWIRED G N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G N2 APARTMENT_LIGHTS_HARDWIRED G N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G S1 APARTMENT_LIGHTS_HARDWIRED G S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G S2 APARTMENT_LIGHTS_HARDWIRED G S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G CORRIDOR_LIGHTS_HARDWIRED G CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F2 SW APARTMENT_LIGHTS_HARDWIRED F2 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 NW APARTMENT_LIGHTS_HARDWIRED F2 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 SE APARTMENT_LIGHTS_HARDWIRED F2 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 NE APARTMENT_LIGHTS_HARDWIRED F2 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 N1 APARTMENT_LIGHTS_HARDWIRED F2 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 N2 APARTMENT_LIGHTS_HARDWIRED F2 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 S1 APARTMENT_LIGHTS_HARDWIRED F2 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 S2 APARTMENT_LIGHTS_HARDWIRED F2 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 CORRIDOR_LIGHTS_HARDWIRED F2 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F3 SW APARTMENT_LIGHTS_HARDWIRED F3 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 NW APARTMENT_LIGHTS_HARDWIRED F3 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 SE APARTMENT_LIGHTS_HARDWIRED F3 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 NE APARTMENT_LIGHTS_HARDWIRED F3 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 N1 APARTMENT_LIGHTS_HARDWIRED F3 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 N2 APARTMENT_LIGHTS_HARDWIRED F3 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 S1 APARTMENT_LIGHTS_HARDWIRED F3 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 S2 APARTMENT_LIGHTS_HARDWIRED F3 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 CORRIDOR_LIGHTS_HARDWIRED F3 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F4 SW APARTMENT_LIGHTS_HARDWIRED F4 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 NW APARTMENT_LIGHTS_HARDWIRED F4 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 SE APARTMENT_LIGHTS_HARDWIRED F4 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 NE APARTMENT_LIGHTS_HARDWIRED F4 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 N1 APARTMENT_LIGHTS_HARDWIRED F4 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 N2 APARTMENT_LIGHTS_HARDWIRED F4 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 S1 APARTMENT_LIGHTS_HARDWIRED F4 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 S2 APARTMENT_LIGHTS_HARDWIRED F4 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 CORRIDOR_LIGHTS_HARDWIRED F4 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
M SW APARTMENT_LIGHTS_HARDWIRED M SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M NW APARTMENT_LIGHTS_HARDWIRED M NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M SE APARTMENT_LIGHTS_HARDWIRED M SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M NE APARTMENT_LIGHTS_HARDWIRED M NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M N1 APARTMENT_LIGHTS_HARDWIRED M N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M N2 APARTMENT_LIGHTS_HARDWIRED M N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M S1 APARTMENT_LIGHTS_HARDWIRED M S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M S2 APARTMENT_LIGHTS_HARDWIRED M S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M CORRIDOR_LIGHTS_HARDWIRED M CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F6 SW APARTMENT_LIGHTS_HARDWIRED F6 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 NW APARTMENT_LIGHTS_HARDWIRED F6 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 SE APARTMENT_LIGHTS_HARDWIRED F6 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 NE APARTMENT_LIGHTS_HARDWIRED F6 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 N1 APARTMENT_LIGHTS_HARDWIRED F6 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 N2 APARTMENT_LIGHTS_HARDWIRED F6 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 S1 APARTMENT_LIGHTS_HARDWIRED F6 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 S2 APARTMENT_LIGHTS_HARDWIRED F6 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 CORRIDOR_LIGHTS_HARDWIRED F6 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F7 SW APARTMENT_LIGHTS_HARDWIRED F7 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 NW APARTMENT_LIGHTS_HARDWIRED F7 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 SE APARTMENT_LIGHTS_HARDWIRED F7 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 NE APARTMENT_LIGHTS_HARDWIRED F7 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 N1 APARTMENT_LIGHTS_HARDWIRED F7 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 N2 APARTMENT_LIGHTS_HARDWIRED F7 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 S1 APARTMENT_LIGHTS_HARDWIRED F7 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 S2 APARTMENT_LIGHTS_HARDWIRED F7 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 CORRIDOR_LIGHTS_HARDWIRED F7 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F8 SW APARTMENT_LIGHTS_HARDWIRED F8 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 NW APARTMENT_LIGHTS_HARDWIRED F8 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 SE APARTMENT_LIGHTS_HARDWIRED F8 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 NE APARTMENT_LIGHTS_HARDWIRED F8 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 N1 APARTMENT_LIGHTS_HARDWIRED F8 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 N2 APARTMENT_LIGHTS_HARDWIRED F8 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 S1 APARTMENT_LIGHTS_HARDWIRED F8 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 S2 APARTMENT_LIGHTS_HARDWIRED F8 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 CORRIDOR_LIGHTS_HARDWIRED F8 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F9 SW APARTMENT_LIGHTS_HARDWIRED F9 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 NW APARTMENT_LIGHTS_HARDWIRED F9 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 SE APARTMENT_LIGHTS_HARDWIRED F9 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 NE APARTMENT_LIGHTS_HARDWIRED F9 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 N1 APARTMENT_LIGHTS_HARDWIRED F9 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 N2 APARTMENT_LIGHTS_HARDWIRED F9 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 S1 APARTMENT_LIGHTS_HARDWIRED F9 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 S2 APARTMENT_LIGHTS_HARDWIRED F9 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 CORRIDOR_LIGHTS_HARDWIRED F9 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
T SW APARTMENT_LIGHTS_HARDWIRED T SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T NW APARTMENT_LIGHTS_HARDWIRED T NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T SE APARTMENT_LIGHTS_HARDWIRED T SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T NE APARTMENT_LIGHTS_HARDWIRED T NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T N1 APARTMENT_LIGHTS_HARDWIRED T N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T N2 APARTMENT_LIGHTS_HARDWIRED T N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T S1 APARTMENT_LIGHTS_HARDWIRED T S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T S2 APARTMENT_LIGHTS_HARDWIRED T S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T CORRIDOR_LIGHTS_HARDWIRED T CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
G SW APARTMENT_LIGHTS_PLUGIN G SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G NW APARTMENT_LIGHTS_PLUGIN G NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
OFFICE_LIGHTS_PLUGIN OFFICE 14.7681 88.25 1303.26 GeneralLights-plugin LTG_OFF_SCH 62.05 168.00 61.07 0.0000 Y 14.94
G NE APARTMENT_LIGHTS_PLUGIN G NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G N1 APARTMENT_LIGHTS_PLUGIN G N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G N2 APARTMENT_LIGHTS_PLUGIN G N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G S1 APARTMENT_LIGHTS_PLUGIN G S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G S2 APARTMENT_LIGHTS_PLUGIN G S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 SW APARTMENT_LIGHTS_PLUGIN F2 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 NW APARTMENT_LIGHTS_PLUGIN F2 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 SE APARTMENT_LIGHTS_PLUGIN F2 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 NE APARTMENT_LIGHTS_PLUGIN F2 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 N1 APARTMENT_LIGHTS_PLUGIN F2 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 N2 APARTMENT_LIGHTS_PLUGIN F2 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 S1 APARTMENT_LIGHTS_PLUGIN F2 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 S2 APARTMENT_LIGHTS_PLUGIN F2 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 SW APARTMENT_LIGHTS_PLUGIN F3 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 NW APARTMENT_LIGHTS_PLUGIN F3 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 SE APARTMENT_LIGHTS_PLUGIN F3 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 NE APARTMENT_LIGHTS_PLUGIN F3 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 N1 APARTMENT_LIGHTS_PLUGIN F3 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 N2 APARTMENT_LIGHTS_PLUGIN F3 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 S1 APARTMENT_LIGHTS_PLUGIN F3 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 S2 APARTMENT_LIGHTS_PLUGIN F3 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 SW APARTMENT_LIGHTS_PLUGIN F4 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 NW APARTMENT_LIGHTS_PLUGIN F4 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 SE APARTMENT_LIGHTS_PLUGIN F4 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 NE APARTMENT_LIGHTS_PLUGIN F4 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 N1 APARTMENT_LIGHTS_PLUGIN F4 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 N2 APARTMENT_LIGHTS_PLUGIN F4 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 S1 APARTMENT_LIGHTS_PLUGIN F4 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 S2 APARTMENT_LIGHTS_PLUGIN F4 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M SW APARTMENT_LIGHTS_PLUGIN M SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M NW APARTMENT_LIGHTS_PLUGIN M NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M SE APARTMENT_LIGHTS_PLUGIN M SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M NE APARTMENT_LIGHTS_PLUGIN M NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M N1 APARTMENT_LIGHTS_PLUGIN M N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M N2 APARTMENT_LIGHTS_PLUGIN M N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M S1 APARTMENT_LIGHTS_PLUGIN M S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M S2 APARTMENT_LIGHTS_PLUGIN M S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M CORRIDOR_LIGHTS_PLUGIN M CORRIDOR 6.7128 77.66 521.30 GeneralLights-plugin LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F6 SW APARTMENT_LIGHTS_PLUGIN F6 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 NW APARTMENT_LIGHTS_PLUGIN F6 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 SE APARTMENT_LIGHTS_PLUGIN F6 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 NE APARTMENT_LIGHTS_PLUGIN F6 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 N1 APARTMENT_LIGHTS_PLUGIN F6 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 N2 APARTMENT_LIGHTS_PLUGIN F6 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 S1 APARTMENT_LIGHTS_PLUGIN F6 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 S2 APARTMENT_LIGHTS_PLUGIN F6 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 SW APARTMENT_LIGHTS_PLUGIN F7 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 NW APARTMENT_LIGHTS_PLUGIN F7 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 SE APARTMENT_LIGHTS_PLUGIN F7 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 NE APARTMENT_LIGHTS_PLUGIN F7 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 N1 APARTMENT_LIGHTS_PLUGIN F7 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 N2 APARTMENT_LIGHTS_PLUGIN F7 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 S1 APARTMENT_LIGHTS_PLUGIN F7 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 S2 APARTMENT_LIGHTS_PLUGIN F7 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 SW APARTMENT_LIGHTS_PLUGIN F8 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 NW APARTMENT_LIGHTS_PLUGIN F8 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 SE APARTMENT_LIGHTS_PLUGIN F8 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 NE APARTMENT_LIGHTS_PLUGIN F8 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 N1 APARTMENT_LIGHTS_PLUGIN F8 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 N2 APARTMENT_LIGHTS_PLUGIN F8 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 S1 APARTMENT_LIGHTS_PLUGIN F8 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 S2 APARTMENT_LIGHTS_PLUGIN F8 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 SW APARTMENT_LIGHTS_PLUGIN F9 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 NW APARTMENT_LIGHTS_PLUGIN F9 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 SE APARTMENT_LIGHTS_PLUGIN F9 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 NE APARTMENT_LIGHTS_PLUGIN F9 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 N1 APARTMENT_LIGHTS_PLUGIN F9 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 N2 APARTMENT_LIGHTS_PLUGIN F9 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 S1 APARTMENT_LIGHTS_PLUGIN F9 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 S2 APARTMENT_LIGHTS_PLUGIN F9 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T SW APARTMENT_LIGHTS_PLUGIN T SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T NW APARTMENT_LIGHTS_PLUGIN T NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T SE APARTMENT_LIGHTS_PLUGIN T SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T NE APARTMENT_LIGHTS_PLUGIN T NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T N1 APARTMENT_LIGHTS_PLUGIN T N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T N2 APARTMENT_LIGHTS_PLUGIN T N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T S1 APARTMENT_LIGHTS_PLUGIN T S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T S2 APARTMENT_LIGHTS_PLUGIN T S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
Interior Lighting Total   2.2679 14974.03 33959.19               296.56


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 10364.00 AstronomicalClock -   83.06 83.06 161.58
Exterior Lighting Total 10364.00           161.58



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
CENTRAL BOILER Boiler:HotWater 247552.88 0.75    
CENTRAL TOWER EvaporativeFluidCooler:SingleSpeed 198042.30      


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
HEAT PUMP COOLING MODE AIRLOOP G SW Coil:Cooling:WaterToAirHeatPump:EquationFit   3265.29 2545.80 719.49 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NW Coil:Cooling:WaterToAirHeatPump:EquationFit   2420.70 1906.71 513.99 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP OFFICE Coil:Cooling:WaterToAirHeatPump:EquationFit   5143.49 4004.00 1139.49 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2383.21 1903.52 479.69 0.80 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1619.08 1332.09 286.99 0.82 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1613.17 1329.66 283.51 0.82 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2499.75 1941.97 557.78 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2593.10 2013.98 579.12 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4363.84 3401.16 962.68 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3088.38 2421.98 666.40 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4559.12 3543.62 1015.51 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2482.40 1967.78 514.62 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1592.03 1277.82 314.21 0.80 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1571.16 1261.79 309.37 0.80 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3391.90 2634.25 757.65 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3426.42 2660.88 765.54 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4395.62 3428.70 966.93 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3132.65 2460.09 672.56 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4292.86 3342.20 950.66 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2532.79 2010.47 522.32 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1653.88 1327.82 326.06 0.80 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1633.37 1312.06 321.31 0.80 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3449.28 2680.97 768.31 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3465.81 2693.72 772.09 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4395.47 3431.61 963.85 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3133.71 2463.92 669.79 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4267.37 3325.53 941.83 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2532.55 2013.07 519.48 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1661.47 1335.50 325.96 0.80 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1640.97 1319.75 321.22 0.80 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3458.07 2689.59 768.48 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3472.10 2700.42 771.69 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4419.48 3452.62 966.86 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3158.44 2485.40 673.04 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4290.57 3345.89 944.68 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2555.59 2033.14 522.46 0.80 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1690.38 1359.23 331.15 0.80 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1669.93 1343.50 326.43 0.80 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3488.24 2714.37 773.86 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3501.89 2724.90 776.99 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4364.80 3412.52 952.28 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3104.02 2445.58 658.44 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4238.42 3307.71 930.71 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2502.11 1993.68 508.43 0.80 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1641.83 1323.18 318.66 0.81 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1621.47 1307.52 313.95 0.81 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3438.51 2677.28 761.23 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3452.12 2687.78 764.34 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4340.19 3395.37 944.82 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3080.11 2428.98 651.13 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4215.88 3292.13 923.75 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2490.45 1983.01 507.44 0.80 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1622.39 1309.33 313.06 0.81 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1602.10 1293.73 308.37 0.81 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3418.17 2662.70 755.47 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3431.75 2673.18 758.57 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4331.01 3389.93 941.08 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3072.78 2424.94 647.83 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4208.44 3288.01 920.43 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2482.97 1978.69 504.28 0.80 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1619.84 1308.36 311.48 0.81 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1599.67 1292.84 306.83 0.81 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3412.81 2659.58 753.23 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3426.40 2670.06 756.34 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4408.67 3452.45 956.22 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3159.65 2493.34 666.32 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4280.34 3345.04 935.30 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2514.10 2004.13 509.97 0.80 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1697.06 1368.64 328.41 0.81 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1676.06 1352.49 323.57 0.81 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3472.54 2706.62 765.93 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3487.82 2718.40 769.42 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5172.71 4039.50 1133.21 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3727.97 2932.23 795.74 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4928.12 3846.69 1081.43 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2892.70 2294.93 597.77 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1879.16 1505.98 373.18 0.80 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1914.77 1519.41 395.36 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   4319.07 3360.83 958.24 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   4334.29 3372.57 961.72 0.78 0.00    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
None            


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
HEAT PUMP HEATING MODE AIRLOOP G SW Coil:Heating:WaterToAirHeatPump:EquationFit   3265.29 0.00
HEAT PUMP HEATING MODE AIRLOOP G NW Coil:Heating:WaterToAirHeatPump:EquationFit   2420.70 0.00
HEAT PUMP HEATING MODE AIRLOOP OFFICE Coil:Heating:WaterToAirHeatPump:EquationFit   5143.49 0.00
HEAT PUMP HEATING MODE AIRLOOP G NE Coil:Heating:WaterToAirHeatPump:EquationFit   2383.21 0.00
HEAT PUMP HEATING MODE AIRLOOP G N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1619.08 0.00
HEAT PUMP HEATING MODE AIRLOOP G N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1613.17 0.00
HEAT PUMP HEATING MODE AIRLOOP G S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2499.75 0.00
HEAT PUMP HEATING MODE AIRLOOP G S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2593.10 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4363.84 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3088.38 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4559.12 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2482.40 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1592.03 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1571.16 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3391.90 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3426.42 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4395.62 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3132.65 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4292.86 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2532.79 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1653.88 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1633.37 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3449.28 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3465.81 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4395.47 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3133.71 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4267.37 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2532.55 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1661.47 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1640.97 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3458.07 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3472.10 0.00
HEAT PUMP HEATING MODE AIRLOOP M SW Coil:Heating:WaterToAirHeatPump:EquationFit   4419.48 0.00
HEAT PUMP HEATING MODE AIRLOOP M NW Coil:Heating:WaterToAirHeatPump:EquationFit   3158.44 0.00
HEAT PUMP HEATING MODE AIRLOOP M SE Coil:Heating:WaterToAirHeatPump:EquationFit   4290.57 0.00
HEAT PUMP HEATING MODE AIRLOOP M NE Coil:Heating:WaterToAirHeatPump:EquationFit   2555.59 0.00
HEAT PUMP HEATING MODE AIRLOOP M N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1690.38 0.00
HEAT PUMP HEATING MODE AIRLOOP M N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1669.93 0.00
HEAT PUMP HEATING MODE AIRLOOP M S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3488.24 0.00
HEAT PUMP HEATING MODE AIRLOOP M S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3501.89 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4364.80 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3104.02 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4238.42 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2502.11 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1641.83 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1621.47 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3438.51 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3452.12 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4340.19 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3080.11 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4215.88 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2490.45 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1622.39 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1602.10 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3418.17 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3431.75 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4331.01 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3072.78 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4208.44 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2482.97 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1619.84 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1599.67 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3412.81 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3426.40 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4408.67 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3159.65 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4280.34 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2514.10 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1697.06 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1676.06 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3472.54 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3487.82 0.00
HEAT PUMP HEATING MODE AIRLOOP T SW Coil:Heating:WaterToAirHeatPump:EquationFit   5172.71 0.00
HEAT PUMP HEATING MODE AIRLOOP T NW Coil:Heating:WaterToAirHeatPump:EquationFit   3727.97 0.00
HEAT PUMP HEATING MODE AIRLOOP T SE Coil:Heating:WaterToAirHeatPump:EquationFit   4928.12 0.00
HEAT PUMP HEATING MODE AIRLOOP T NE Coil:Heating:WaterToAirHeatPump:EquationFit   2892.70 0.00
HEAT PUMP HEATING MODE AIRLOOP T N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1879.16 0.00
HEAT PUMP HEATING MODE AIRLOOP T N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1914.77 0.00
HEAT PUMP HEATING MODE AIRLOOP T S1 Coil:Heating:WaterToAirHeatPump:EquationFit   4319.07 0.00
HEAT PUMP HEATING MODE AIRLOOP T S2 Coil:Heating:WaterToAirHeatPump:EquationFit   4334.29 0.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW Coil:Heating:Electric   5905.22 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW Coil:Heating:Electric   5918.27 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE Coil:Heating:Electric   7328.82 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE Coil:Heating:Electric   5916.51 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 Coil:Heating:Electric   4891.70 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 Coil:Heating:Electric   4891.66 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 Coil:Heating:Electric   4877.08 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 Coil:Heating:Electric   4883.34 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW Coil:Heating:Electric   4951.99 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW Coil:Heating:Electric   4945.96 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE Coil:Heating:Electric   4966.93 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE Coil:Heating:Electric   4943.19 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 Coil:Heating:Electric   3763.43 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 Coil:Heating:Electric   3763.37 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 Coil:Heating:Electric   3772.96 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 Coil:Heating:Electric   3773.94 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW Coil:Heating:Electric   4745.26 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW Coil:Heating:Electric   4741.48 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE Coil:Heating:Electric   4743.72 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE Coil:Heating:Electric   4738.20 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 Coil:Heating:Electric   3551.20 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 Coil:Heating:Electric   3551.13 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 Coil:Heating:Electric   3556.57 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 Coil:Heating:Electric   3556.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW Coil:Heating:Electric   4721.83 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW Coil:Heating:Electric   4718.56 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE Coil:Heating:Electric   4718.33 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE Coil:Heating:Electric   4714.89 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 Coil:Heating:Electric   3517.34 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 Coil:Heating:Electric   3517.26 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 Coil:Heating:Electric   3521.90 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 Coil:Heating:Electric   3521.84 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW Coil:Heating:Electric   4702.63 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW Coil:Heating:Electric   4698.25 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE Coil:Heating:Electric   4698.68 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE Coil:Heating:Electric   4694.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 Coil:Heating:Electric   3490.36 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 Coil:Heating:Electric   3490.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 Coil:Heating:Electric   3496.11 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 Coil:Heating:Electric   3496.03 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW Coil:Heating:Electric   4754.51 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW Coil:Heating:Electric   4750.51 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE Coil:Heating:Electric   4750.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE Coil:Heating:Electric   4746.27 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 Coil:Heating:Electric   3533.67 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 Coil:Heating:Electric   3533.58 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 Coil:Heating:Electric   3538.90 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 Coil:Heating:Electric   3538.81 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW Coil:Heating:Electric   4783.04 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW Coil:Heating:Electric   4778.47 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE Coil:Heating:Electric   4778.58 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE Coil:Heating:Electric   4774.01 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 Coil:Heating:Electric   3555.95 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 Coil:Heating:Electric   3555.85 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 Coil:Heating:Electric   3561.77 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 Coil:Heating:Electric   3561.68 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW Coil:Heating:Electric   4826.57 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW Coil:Heating:Electric   4821.08 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE Coil:Heating:Electric   4821.92 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE Coil:Heating:Electric   4816.42 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 Coil:Heating:Electric   3593.90 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 Coil:Heating:Electric   3593.80 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 Coil:Heating:Electric   3600.67 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 Coil:Heating:Electric   3600.58 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW Coil:Heating:Electric   5074.16 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW Coil:Heating:Electric   5064.08 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE Coil:Heating:Electric   5069.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE Coil:Heating:Electric   5059.19 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 Coil:Heating:Electric   3820.24 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 Coil:Heating:Electric   3820.13 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 Coil:Heating:Electric   3831.16 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 Coil:Heating:Electric   3831.06 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW Coil:Heating:Electric   6182.34 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW Coil:Heating:Electric   6182.64 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE Coil:Heating:Electric   6177.58 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE Coil:Heating:Electric   6177.88 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 Coil:Heating:Electric   5008.93 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 Coil:Heating:Electric   5008.82 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 Coil:Heating:Electric   5006.35 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 Coil:Heating:Electric   5006.24 1.00


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
AIRLOOP G SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 275.58 1160.84 1.00 General
AIRLOOP G NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 210.46 1160.84 1.00 General
AIRLOOP OFFICE SUPPLY FAN Fan:OnOff 0.54 622.50 0.37 432.06 1160.84 1.00 General
AIRLOOP G NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 210.36 1160.84 1.00 General
AIRLOOP G N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 155.79 1160.84 1.00 General
AIRLOOP G N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 155.79 1160.84 1.00 General
AIRLOOP G S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 208.43 1160.84 1.00 General
AIRLOOP G S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 216.25 1160.84 1.00 General
AIRLOOP F2 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 369.14 1160.84 1.00 General
AIRLOOP F2 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 266.34 1160.84 1.00 General
AIRLOOP F2 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.33 383.07 1160.84 1.00 General
AIRLOOP F2 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 216.67 1160.84 1.00 General
AIRLOOP F2 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 145.34 1160.84 1.00 General
AIRLOOP F2 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 143.60 1160.84 1.00 General
AIRLOOP F2 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 283.82 1160.84 1.00 General
AIRLOOP F2 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 286.72 1160.84 1.00 General
AIRLOOP F3 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 372.06 1160.84 1.00 General
AIRLOOP F3 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 270.68 1160.84 1.00 General
AIRLOOP F3 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 361.40 1160.84 1.00 General
AIRLOOP F3 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 221.50 1160.84 1.00 General
AIRLOOP F3 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 150.88 1160.84 1.00 General
AIRLOOP F3 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 149.17 1160.84 1.00 General
AIRLOOP F3 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 289.03 1160.84 1.00 General
AIRLOOP F3 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 290.41 1160.84 1.00 General
AIRLOOP F4 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 372.54 1160.84 1.00 General
AIRLOOP F4 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 271.25 1160.84 1.00 General
AIRLOOP F4 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 359.74 1160.84 1.00 General
AIRLOOP F4 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 221.93 1160.84 1.00 General
AIRLOOP F4 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 151.80 1160.84 1.00 General
AIRLOOP F4 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 150.10 1160.84 1.00 General
AIRLOOP F4 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 290.06 1160.84 1.00 General
AIRLOOP F4 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 291.24 1160.84 1.00 General
AIRLOOP M SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 374.95 1160.84 1.00 General
AIRLOOP M NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 273.71 1160.84 1.00 General
AIRLOOP M SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 362.08 1160.84 1.00 General
AIRLOOP M NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 224.22 1160.84 1.00 General
AIRLOOP M N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 154.45 1160.84 1.00 General
AIRLOOP M N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 152.75 1160.84 1.00 General
AIRLOOP M S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 292.83 1160.84 1.00 General
AIRLOOP M S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 293.97 1160.84 1.00 General
AIRLOOP F6 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 370.70 1160.84 1.00 General
AIRLOOP F6 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 269.50 1160.84 1.00 General
AIRLOOP F6 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 358.04 1160.84 1.00 General
AIRLOOP F6 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 220.03 1160.84 1.00 General
AIRLOOP F6 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 150.61 1160.84 1.00 General
AIRLOOP F6 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 148.91 1160.84 1.00 General
AIRLOOP F6 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 288.87 1160.84 1.00 General
AIRLOOP F6 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 290.01 1160.84 1.00 General
AIRLOOP F7 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 368.93 1160.84 1.00 General
AIRLOOP F7 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 267.79 1160.84 1.00 General
AIRLOOP F7 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 356.44 1160.84 1.00 General
AIRLOOP F7 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 218.35 1160.84 1.00 General
AIRLOOP F7 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 149.16 1160.84 1.00 General
AIRLOOP F7 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 147.47 1160.84 1.00 General
AIRLOOP F7 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 287.34 1160.84 1.00 General
AIRLOOP F7 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 288.48 1160.84 1.00 General
AIRLOOP F8 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 368.43 1160.84 1.00 General
AIRLOOP F8 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 267.43 1160.84 1.00 General
AIRLOOP F8 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 356.08 1160.84 1.00 General
AIRLOOP F8 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 217.95 1160.84 1.00 General
AIRLOOP F8 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 149.11 1160.84 1.00 General
AIRLOOP F8 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 147.43 1160.84 1.00 General
AIRLOOP F8 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 287.06 1160.84 1.00 General
AIRLOOP F8 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 288.19 1160.84 1.00 General
AIRLOOP F9 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 375.58 1160.84 1.00 General
AIRLOOP F9 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 274.94 1160.84 1.00 General
AIRLOOP F9 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 362.36 1160.84 1.00 General
AIRLOOP F9 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 220.79 1160.84 1.00 General
AIRLOOP F9 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 155.69 1160.84 1.00 General
AIRLOOP F9 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 153.94 1160.84 1.00 General
AIRLOOP F9 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 292.21 1160.84 1.00 General
AIRLOOP F9 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 293.50 1160.84 1.00 General
AIRLOOP T SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.38 438.62 1160.84 1.00 General
AIRLOOP T NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 320.90 1160.84 1.00 General
AIRLOOP T SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.36 416.95 1160.84 1.00 General
AIRLOOP T NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 251.89 1160.84 1.00 General
AIRLOOP T N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.15 169.86 1160.84 1.00 General
AIRLOOP T N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 166.66 1160.84 1.00 General
AIRLOOP T S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 363.34 1160.84 1.00 General
AIRLOOP T S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 364.61 1160.84 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
SHWSYS1 PUMP Pump:ConstantSpeed Intermittent 29891.00 0.0003 36.93 127739.32 0.30
PLANT CIRC PUMP Pump:ConstantSpeed Intermittent 224180.02 0.0054 1719.50 319344.75 0.90


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
SHWSYS1 WATER HEATER WaterHeater:Mixed 2.27 175842.64 0.80 0.00 0.00



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 2487.05 2984.46 0.198 0.237 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 26.58 0.00698
G NW APARTMENT 1722.29 2066.75 0.137 0.164 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 23.42 0.00698
OFFICE 3899.32 4679.19 0.310 0.372 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 27.40 0.00698
G NE APARTMENT 1317.87 1581.45 0.105 0.126 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 24.29 0.00698
G N1 APARTMENT 839.62 1007.55 0.067 0.080 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:15:00 21.15 0.00698
G N2 APARTMENT 822.37 986.84 0.065 0.078 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:15:00 21.15 0.00698
G S1 APARTMENT 1881.06 2257.27 0.150 0.180 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40 0.00698
G S2 APARTMENT 1951.62 2341.94 0.155 0.186 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 27.40 0.00698
F2 SW APARTMENT 3331.43 3997.72 0.265 0.318 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 26.38 0.00698
F2 NW APARTMENT 2403.62 2884.35 0.191 0.229 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 23.42 0.00698
F2 SE APARTMENT 3457.15 4148.58 0.275 0.330 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 27.40 0.00698
F2 NE APARTMENT 1955.41 2346.49 0.156 0.187 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 24.29 0.00698
F2 N1 APARTMENT 1311.60 1573.92 0.104 0.125 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:15:00 21.15 0.00698
F2 N2 APARTMENT 1295.94 1555.13 0.103 0.124 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:15:00 21.15 0.00698
F2 S1 APARTMENT 2561.47 3073.76 0.204 0.244 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40 0.00698
F2 S2 APARTMENT 2587.57 3105.09 0.206 0.247 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40 0.00698
F3 SW APARTMENT 3357.83 4029.39 0.267 0.321 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 26.58 0.00698
F3 NW APARTMENT 2442.85 2931.42 0.194 0.233 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 23.42 0.00698
F3 SE APARTMENT 3261.59 3913.91 0.259 0.311 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 27.40 0.00698
F3 NE APARTMENT 1999.03 2398.84 0.159 0.191 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 24.29 0.00698
F3 N1 APARTMENT 1361.61 1633.93 0.108 0.130 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:15:00 21.15 0.00698
F3 N2 APARTMENT 1346.21 1615.45 0.107 0.129 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:15:00 21.15 0.00698
F3 S1 APARTMENT 2608.43 3130.11 0.207 0.249 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40 0.00698
F3 S2 APARTMENT 2620.93 3145.11 0.208 0.250 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40 0.00698
F4 SW APARTMENT 3362.13 4034.55 0.267 0.321 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 26.58 0.00698
F4 NW APARTMENT 2448.02 2937.63 0.195 0.234 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 23.42 0.00698
F4 SE APARTMENT 3246.66 3895.99 0.258 0.310 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 27.40 0.00698
F4 NE APARTMENT 2002.86 2403.44 0.159 0.191 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 24.29 0.00698
F4 N1 APARTMENT 1369.98 1643.97 0.109 0.131 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:15:00 21.15 0.00698
F4 N2 APARTMENT 1354.57 1625.48 0.108 0.129 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:15:00 21.15 0.00698
F4 S1 APARTMENT 2617.75 3141.30 0.208 0.250 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40 0.00698
F4 S2 APARTMENT 2628.36 3154.04 0.209 0.251 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40 0.00698
M SW APARTMENT 3383.90 4060.68 0.269 0.323 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 26.58 0.00698
M NW APARTMENT 2470.21 2964.25 0.196 0.236 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 23.42 0.00698
M SE APARTMENT 3267.78 3921.34 0.260 0.312 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 27.40 0.00698
M NE APARTMENT 2023.61 2428.33 0.161 0.193 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 24.29 0.00698
M N1 APARTMENT 1393.86 1672.63 0.111 0.133 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:15:00 21.15 0.00698
M N2 APARTMENT 1378.48 1654.17 0.110 0.132 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:15:00 21.15 0.00698
M S1 APARTMENT 2642.76 3171.31 0.210 0.252 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40 0.00698
M S2 APARTMENT 2653.08 3183.70 0.211 0.253 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40 0.00698
F6 SW APARTMENT 3345.56 4014.67 0.266 0.319 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 26.58 0.00698
F6 NW APARTMENT 2432.17 2918.61 0.193 0.232 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 23.42 0.00698
F6 SE APARTMENT 3231.31 3877.58 0.257 0.308 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 27.40 0.00698
F6 NE APARTMENT 1985.74 2382.88 0.158 0.190 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 24.29 0.00698
F6 N1 APARTMENT 1359.19 1631.02 0.108 0.130 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:15:00 21.15 0.00698
F6 N2 APARTMENT 1343.87 1612.65 0.107 0.128 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:15:00 21.15 0.00698
F6 S1 APARTMENT 2606.99 3128.39 0.207 0.249 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40 0.00698
F6 S2 APARTMENT 2617.29 3140.74 0.208 0.250 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40 0.00698
F7 SW APARTMENT 3329.60 3995.53 0.265 0.318 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 26.58 0.00698
F7 NW APARTMENT 2416.76 2900.11 0.192 0.231 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 23.42 0.00698
F7 SE APARTMENT 3216.90 3860.27 0.256 0.307 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 27.40 0.00698
F7 NE APARTMENT 1970.58 2364.70 0.157 0.188 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:45:00 24.67 0.00698
F7 N1 APARTMENT 1346.15 1615.38 0.107 0.128 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:15:00 21.15 0.00698
F7 N2 APARTMENT 1330.90 1597.07 0.106 0.127 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:15:00 21.15 0.00698
F7 S1 APARTMENT 2593.24 3111.89 0.206 0.248 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40 0.00698
F7 S2 APARTMENT 2603.51 3124.21 0.207 0.249 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40 0.00698
F8 SW APARTMENT 3325.05 3990.06 0.264 0.317 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 26.58 0.00698
F8 NW APARTMENT 2413.56 2896.27 0.192 0.230 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 23.42 0.00698
F8 SE APARTMENT 3213.62 3856.35 0.256 0.307 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 27.40 0.00698
F8 NE APARTMENT 1967.01 2360.41 0.156 0.188 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:45:00 24.67 0.00698
F8 N1 APARTMENT 1345.65 1614.78 0.107 0.128 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:15:00 21.15 0.00698
F8 N2 APARTMENT 1330.47 1596.56 0.106 0.127 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:15:00 21.15 0.00698
F8 S1 APARTMENT 2590.65 3108.78 0.206 0.247 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40 0.00698
F8 S2 APARTMENT 2600.92 3121.11 0.207 0.248 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40 0.00698
F9 SW APARTMENT 3389.59 4067.51 0.270 0.324 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 26.38 0.00698
F9 NW APARTMENT 2481.27 2977.52 0.197 0.237 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 23.42 0.00698
F9 SE APARTMENT 3270.27 3924.32 0.260 0.312 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 27.40 0.00698
F9 NE APARTMENT 1992.61 2391.13 0.158 0.190 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 10:45:00 24.67 0.00698
F9 N1 APARTMENT 1405.03 1686.03 0.112 0.134 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:15:00 21.15 0.00698
F9 N2 APARTMENT 1389.22 1667.06 0.111 0.133 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 21:15:00 21.15 0.00698
F9 S1 APARTMENT 2637.21 3164.65 0.210 0.252 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40 0.00698
F9 S2 APARTMENT 2648.76 3178.52 0.211 0.253 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 27.40 0.00698
T SW APARTMENT 3958.52 4750.23 0.315 0.378 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 15:45:00 26.94 0.00698
T NW APARTMENT 2896.12 3475.35 0.230 0.276 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 24.95 0.00698
T SE APARTMENT 3763.00 4515.60 0.299 0.359 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 27.40 0.00698
T NE APARTMENT 2273.36 2728.04 0.181 0.217 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 11:00:00 25.05 0.00698
T N1 APARTMENT 1532.95 1839.53 0.122 0.146 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 20:45:00 21.61 0.00698
T N2 APARTMENT 1504.06 1804.87 0.120 0.144 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 24.95 0.00698
T S1 APARTMENT 3279.10 3934.92 0.261 0.313 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 27.40 0.00698
T S2 APARTMENT 3290.61 3948.73 0.262 0.314 FAIRBANKS INTL ARPT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 27.40 0.00698


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 3331.07 3997.28 0.151 0.181 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -41.90 0.00006
G NW APARTMENT 3342.11 4010.53 0.151 0.181 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -41.90 0.00006
OFFICE 3756.47 4507.77 0.170 0.204 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 18:45:00 -41.90 0.00006
G NE APARTMENT 3340.61 4008.74 0.151 0.181 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -41.90 0.00006
G N1 APARTMENT 2473.98 2968.77 0.112 0.134 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -41.90 0.00006
G N2 APARTMENT 2473.95 2968.73 0.112 0.134 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -41.90 0.00006
G S1 APARTMENT 2461.62 2953.94 0.111 0.134 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -41.90 0.00006
G S2 APARTMENT 2466.91 2960.29 0.112 0.134 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -41.90 0.00006
F2 SW APARTMENT 2524.98 3029.97 0.114 0.137 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F2 NW APARTMENT 2519.88 3023.85 0.114 0.137 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F2 SE APARTMENT 2537.61 3045.13 0.115 0.138 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F2 NE APARTMENT 2517.54 3021.04 0.114 0.137 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F2 N1 APARTMENT 1519.86 1823.84 0.069 0.082 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F2 N2 APARTMENT 1519.82 1823.78 0.069 0.082 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F2 S1 APARTMENT 1527.92 1833.51 0.069 0.083 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F2 S2 APARTMENT 1528.76 1834.51 0.069 0.083 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F3 SW APARTMENT 2350.15 2820.18 0.106 0.127 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F3 NW APARTMENT 2346.96 2816.35 0.106 0.127 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F3 SE APARTMENT 2348.85 2818.62 0.106 0.127 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F3 NE APARTMENT 2344.19 2813.03 0.106 0.127 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F3 N1 APARTMENT 1340.39 1608.47 0.061 0.073 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F3 N2 APARTMENT 1340.33 1608.40 0.061 0.073 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F3 S1 APARTMENT 1344.93 1613.92 0.061 0.073 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F3 S2 APARTMENT 1345.00 1614.00 0.061 0.073 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F4 SW APARTMENT 2330.34 2796.41 0.105 0.126 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F4 NW APARTMENT 2327.58 2793.10 0.105 0.126 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F4 SE APARTMENT 2327.38 2792.86 0.105 0.126 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F4 NE APARTMENT 2324.48 2789.37 0.105 0.126 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F4 N1 APARTMENT 1311.76 1574.11 0.059 0.071 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F4 N2 APARTMENT 1311.69 1574.03 0.059 0.071 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F4 S1 APARTMENT 1315.62 1578.74 0.059 0.071 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F4 S2 APARTMENT 1315.57 1578.68 0.059 0.071 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
M SW APARTMENT 2314.11 2776.93 0.105 0.126 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
M NW APARTMENT 2310.40 2772.49 0.104 0.125 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
M SE APARTMENT 2310.77 2772.92 0.104 0.125 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
M NE APARTMENT 2307.05 2768.46 0.104 0.125 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
M N1 APARTMENT 1288.95 1546.74 0.058 0.070 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
M N2 APARTMENT 1288.88 1546.65 0.058 0.070 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
M S1 APARTMENT 1293.81 1552.57 0.058 0.070 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
M S2 APARTMENT 1293.74 1552.49 0.058 0.070 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F6 SW APARTMENT 2357.98 2829.58 0.107 0.128 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F6 NW APARTMENT 2354.60 2825.52 0.106 0.128 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F6 SE APARTMENT 2354.41 2825.29 0.106 0.128 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F6 NE APARTMENT 2351.01 2821.21 0.106 0.128 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F6 N1 APARTMENT 1325.57 1590.68 0.060 0.072 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F6 N2 APARTMENT 1325.49 1590.59 0.060 0.072 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F6 S1 APARTMENT 1329.99 1595.99 0.060 0.072 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F6 S2 APARTMENT 1329.91 1595.90 0.060 0.072 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F7 SW APARTMENT 2382.11 2858.53 0.108 0.129 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F7 NW APARTMENT 2378.25 2853.89 0.108 0.129 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F7 SE APARTMENT 2378.34 2854.00 0.108 0.129 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F7 NE APARTMENT 2374.47 2849.37 0.107 0.129 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F7 N1 APARTMENT 1344.41 1613.29 0.061 0.073 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F7 N2 APARTMENT 1344.33 1613.20 0.061 0.073 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F7 S1 APARTMENT 1349.34 1619.20 0.061 0.073 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F7 S2 APARTMENT 1349.26 1619.11 0.061 0.073 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F8 SW APARTMENT 2418.92 2902.71 0.109 0.131 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F8 NW APARTMENT 2414.28 2897.14 0.109 0.131 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F8 SE APARTMENT 2414.99 2897.98 0.109 0.131 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F8 NE APARTMENT 2410.34 2892.41 0.109 0.131 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F8 N1 APARTMENT 1376.51 1651.81 0.062 0.075 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F8 N2 APARTMENT 1376.42 1651.71 0.062 0.075 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F8 S1 APARTMENT 1382.23 1658.68 0.062 0.075 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F8 S2 APARTMENT 1382.15 1658.58 0.062 0.075 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F9 SW APARTMENT 2628.29 3153.95 0.119 0.143 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F9 NW APARTMENT 2619.77 3143.72 0.118 0.142 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F9 SE APARTMENT 2624.16 3149.00 0.119 0.142 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F9 NE APARTMENT 2615.64 3138.76 0.118 0.142 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F9 N1 APARTMENT 1567.91 1881.49 0.071 0.085 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F9 N2 APARTMENT 1567.82 1881.38 0.071 0.085 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F9 S1 APARTMENT 1577.15 1892.58 0.071 0.086 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
F9 S2 APARTMENT 1577.06 1892.47 0.071 0.086 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
T SW APARTMENT 3565.43 4278.51 0.161 0.193 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
T NW APARTMENT 3565.68 4278.82 0.161 0.193 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
T SE APARTMENT 3561.41 4273.69 0.161 0.193 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
T NE APARTMENT 3561.66 4273.99 0.161 0.193 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
T N1 APARTMENT 2573.13 3087.75 0.116 0.140 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
T N2 APARTMENT 2573.04 3087.65 0.116 0.140 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
T S1 APARTMENT 2570.95 3085.14 0.116 0.139 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006
T S2 APARTMENT 2570.86 3085.03 0.116 0.139 FAIRBANKS INTL ARPT ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -41.90 0.00006


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
AIRLOOP G SW 0.24 0.24 0.18 0.18
AIRLOOP G NW 0.16 0.16 0.18 0.18
AIRLOOP OFFICE 0.37 0.37 0.20 0.20
AIRLOOP G NE 0.13 0.13 0.18 0.18
AIRLOOP G N1 0.08 0.08 0.13 0.13
AIRLOOP G N2 0.08 0.08 0.13 0.13
AIRLOOP G S1 0.18 0.18 0.13 0.13
AIRLOOP G S2 0.19 0.19 0.13 0.13
AIRLOOP F2 SW 0.32 0.32 0.14 0.14
AIRLOOP F2 NW 0.23 0.23 0.14 0.14
AIRLOOP F2 SE 0.33 0.33 0.14 0.14
AIRLOOP F2 NE 0.19 0.19 0.14 0.14
AIRLOOP F2 N1 0.13 0.13 0.08 0.08
AIRLOOP F2 N2 0.12 0.12 0.08 0.08
AIRLOOP F2 S1 0.24 0.24 0.08 0.08
AIRLOOP F2 S2 0.25 0.25 0.08 0.08
AIRLOOP F3 SW 0.32 0.32 0.13 0.13
AIRLOOP F3 NW 0.23 0.23 0.13 0.13
AIRLOOP F3 SE 0.31 0.31 0.13 0.13
AIRLOOP F3 NE 0.19 0.19 0.13 0.13
AIRLOOP F3 N1 0.13 0.13 0.07 0.07
AIRLOOP F3 N2 0.13 0.13 0.07 0.07
AIRLOOP F3 S1 0.25 0.25 0.07 0.07
AIRLOOP F3 S2 0.25 0.25 0.07 0.07
AIRLOOP F4 SW 0.32 0.32 0.13 0.13
AIRLOOP F4 NW 0.23 0.23 0.13 0.13
AIRLOOP F4 SE 0.31 0.31 0.13 0.13
AIRLOOP F4 NE 0.19 0.19 0.13 0.13
AIRLOOP F4 N1 0.13 0.13 0.07 0.07
AIRLOOP F4 N2 0.13 0.13 0.07 0.07
AIRLOOP F4 S1 0.25 0.25 0.07 0.07
AIRLOOP F4 S2 0.25 0.25 0.07 0.07
AIRLOOP M SW 0.32 0.32 0.13 0.13
AIRLOOP M NW 0.24 0.24 0.13 0.13
AIRLOOP M SE 0.31 0.31 0.13 0.13
AIRLOOP M NE 0.19 0.19 0.13 0.13
AIRLOOP M N1 0.13 0.13 0.07 0.07
AIRLOOP M N2 0.13 0.13 0.07 0.07
AIRLOOP M S1 0.25 0.25 0.07 0.07
AIRLOOP M S2 0.25 0.25 0.07 0.07
AIRLOOP F6 SW 0.32 0.32 0.13 0.13
AIRLOOP F6 NW 0.23 0.23 0.13 0.13
AIRLOOP F6 SE 0.31 0.31 0.13 0.13
AIRLOOP F6 NE 0.19 0.19 0.13 0.13
AIRLOOP F6 N1 0.13 0.13 0.07 0.07
AIRLOOP F6 N2 0.13 0.13 0.07 0.07
AIRLOOP F6 S1 0.25 0.25 0.07 0.07
AIRLOOP F6 S2 0.25 0.25 0.07 0.07
AIRLOOP F7 SW 0.32 0.32 0.13 0.13
AIRLOOP F7 NW 0.23 0.23 0.13 0.13
AIRLOOP F7 SE 0.31 0.31 0.13 0.13
AIRLOOP F7 NE 0.19 0.19 0.13 0.13
AIRLOOP F7 N1 0.13 0.13 0.07 0.07
AIRLOOP F7 N2 0.13 0.13 0.07 0.07
AIRLOOP F7 S1 0.25 0.25 0.07 0.07
AIRLOOP F7 S2 0.25 0.25 0.07 0.07
AIRLOOP F8 SW 0.32 0.32 0.13 0.13
AIRLOOP F8 NW 0.23 0.23 0.13 0.13
AIRLOOP F8 SE 0.31 0.31 0.13 0.13
AIRLOOP F8 NE 0.19 0.19 0.13 0.13
AIRLOOP F8 N1 0.13 0.13 0.07 0.07
AIRLOOP F8 N2 0.13 0.13 0.07 0.07
AIRLOOP F8 S1 0.25 0.25 0.07 0.07
AIRLOOP F8 S2 0.25 0.25 0.07 0.07
AIRLOOP F9 SW 0.32 0.32 0.14 0.14
AIRLOOP F9 NW 0.24 0.24 0.14 0.14
AIRLOOP F9 SE 0.31 0.31 0.14 0.14
AIRLOOP F9 NE 0.19 0.19 0.14 0.14
AIRLOOP F9 N1 0.13 0.13 0.09 0.09
AIRLOOP F9 N2 0.13 0.13 0.09 0.09
AIRLOOP F9 S1 0.25 0.25 0.09 0.09
AIRLOOP F9 S2 0.25 0.25 0.09 0.09
AIRLOOP T SW 0.38 0.38 0.19 0.19
AIRLOOP T NW 0.28 0.28 0.19 0.19
AIRLOOP T SE 0.36 0.36 0.19 0.19
AIRLOOP T NE 0.22 0.22 0.19 0.19
AIRLOOP T N1 0.15 0.15 0.14 0.14
AIRLOOP T N2 0.14 0.14 0.14 0.14
AIRLOOP T S1 0.31 0.31 0.14 0.14
AIRLOOP T S2 0.31 0.31 0.14 0.14



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 4317.75 6955.00 3414.50
G NW APARTMENT 4427.25 7627.25 3949.00
OFFICE 1260.75 1363.75 695.50
G NE APARTMENT 4525.50 7469.75 3891.25
G N1 APARTMENT 3751.50 7806.25 3456.25
G N2 APARTMENT 3753.75 7790.75 3454.00
G S1 APARTMENT 3527.00 7039.25 2743.50
G S2 APARTMENT 3540.50 6936.75 2697.25
F2 SW APARTMENT 4127.50 5888.50 2484.50
F2 NW APARTMENT 4206.00 6928.75 3119.75
F2 SE APARTMENT 4290.75 5638.25 2289.50
F2 NE APARTMENT 4216.00 6798.00 3026.00
F2 N1 APARTMENT 2479.75 7122.00 1611.00
F2 N2 APARTMENT 2486.00 7112.75 1608.50
F2 S1 APARTMENT 2696.75 5758.50 1109.25
F2 S2 APARTMENT 2716.25 5719.00 1092.00
F3 SW APARTMENT 4036.75 5748.50 2243.00
F3 NW APARTMENT 4082.50 6773.00 2906.25
F3 SE APARTMENT 4182.50 5639.50 2188.50
F3 NE APARTMENT 4099.25 6651.25 2792.50
F3 N1 APARTMENT 2222.00 6935.75 1199.75
F3 N2 APARTMENT 2228.25 6917.00 1198.50
F3 S1 APARTMENT 2515.00 5533.00 732.00
F3 S2 APARTMENT 2534.25 5515.75 730.25
F4 SW APARTMENT 4037.25 5740.75 2205.50
F4 NW APARTMENT 4073.25 6732.50 2880.75
F4 SE APARTMENT 4154.75 5656.75 2168.25
F4 NE APARTMENT 4087.25 6618.75 2766.50
F4 N1 APARTMENT 2213.00 6848.25 1147.75
F4 N2 APARTMENT 2221.00 6832.50 1146.75
F4 S1 APARTMENT 2525.75 5496.50 677.00
F4 S2 APARTMENT 2535.00 5487.50 675.25
M SW APARTMENT 3986.50 5762.50 2167.00
M NW APARTMENT 4026.50 6748.25 2833.25
M SE APARTMENT 4111.00 5676.75 2134.75
M NE APARTMENT 4035.75 6638.00 2725.25
M N1 APARTMENT 2166.50 6839.50 1083.25
M N2 APARTMENT 2178.25 6823.50 1083.50
M S1 APARTMENT 2480.25 5497.50 621.25
M S2 APARTMENT 2488.00 5488.75 619.50
F6 SW APARTMENT 3971.00 5872.75 2272.75
F6 NW APARTMENT 4064.50 6879.50 2952.50
F6 SE APARTMENT 4103.50 5774.00 2234.25
F6 NE APARTMENT 4062.00 6760.75 2840.75
F6 N1 APARTMENT 2177.75 6974.50 1191.00
F6 N2 APARTMENT 2183.25 6961.50 1189.50
F6 S1 APARTMENT 2460.25 5616.00 725.25
F6 S2 APARTMENT 2475.00 5605.25 723.25
F7 SW APARTMENT 3951.00 5964.25 2337.25
F7 NW APARTMENT 4072.50 6974.75 3009.00
F7 SE APARTMENT 4099.75 5860.25 2293.75
F7 NE APARTMENT 4078.75 6858.50 2906.75
F7 N1 APARTMENT 2171.75 7081.75 1250.00
F7 N2 APARTMENT 2178.25 7063.75 1249.00
F7 S1 APARTMENT 2436.50 5704.75 780.00
F7 S2 APARTMENT 2452.50 5687.75 778.50
F8 SW APARTMENT 3947.75 6049.75 2408.25
F8 NW APARTMENT 4094.75 7059.00 3073.00
F8 SE APARTMENT 4102.25 5932.50 2364.00
F8 NE APARTMENT 4105.75 6943.00 2974.75
F8 N1 APARTMENT 2218.25 7166.25 1341.25
F8 N2 APARTMENT 2225.00 7151.00 1338.00
F8 S1 APARTMENT 2447.50 5790.50 858.50
F8 S2 APARTMENT 2460.75 5776.50 857.00
F9 SW APARTMENT 4130.00 6173.75 2664.25
F9 NW APARTMENT 4289.25 7130.00 3305.00
F9 SE APARTMENT 4263.50 6043.75 2613.50
F9 NE APARTMENT 4310.50 7027.50 3214.00
F9 N1 APARTMENT 2632.75 7243.75 1789.50
F9 N2 APARTMENT 2637.25 7237.50 1783.25
F9 S1 APARTMENT 2733.25 5937.00 1253.00
F9 S2 APARTMENT 2748.75 5918.25 1250.50
T SW APARTMENT 5092.25 6445.25 3626.00
T NW APARTMENT 5051.00 7169.50 4091.00
T SE APARTMENT 5166.00 6356.25 3571.25
T NE APARTMENT 5095.75 7110.25 4024.50
T N1 APARTMENT 4398.75 7335.75 3559.00
T N2 APARTMENT 4405.00 7327.25 3558.25
T S1 APARTMENT 4446.25 6277.75 2958.75
T S2 APARTMENT 4459.25 6262.25 2955.50
G CORRIDOR 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00
Facility 6543.00 7890.75 4220.50
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 1.75 0.00 1.75 0.00
G NW APARTMENT 1.25 0.00 1.25 0.00
OFFICE 2.75 0.00 0.75 0.00
G NE APARTMENT 3.00 0.00 3.00 0.00
G N1 APARTMENT 2.75 0.00 2.75 0.00
G N2 APARTMENT 3.25 0.00 3.25 0.00
G S1 APARTMENT 1.00 0.00 1.00 0.00
G S2 APARTMENT 0.75 0.00 0.75 0.00
F2 SW APARTMENT 1.25 0.00 1.25 0.00
F2 NW APARTMENT 2.00 0.00 2.00 0.00
F2 SE APARTMENT 1.00 0.00 1.00 0.00
F2 NE APARTMENT 2.25 0.00 2.25 0.00
F2 N1 APARTMENT 0.50 2.75 0.50 2.75
F2 N2 APARTMENT 0.75 3.00 0.75 3.00
F2 S1 APARTMENT 1.75 0.00 1.75 0.00
F2 S2 APARTMENT 1.50 0.00 1.50 0.00
F3 SW APARTMENT 1.00 0.00 1.00 0.00
F3 NW APARTMENT 1.50 0.00 1.50 0.00
F3 SE APARTMENT 2.25 0.00 2.25 0.00
F3 NE APARTMENT 1.50 0.00 1.50 0.00
F3 N1 APARTMENT 1.25 6.25 1.25 6.25
F3 N2 APARTMENT 0.75 7.25 0.75 7.25
F3 S1 APARTMENT 3.75 0.00 3.75 0.00
F3 S2 APARTMENT 2.75 0.00 2.75 0.00
F4 SW APARTMENT 0.75 0.00 0.75 0.00
F4 NW APARTMENT 1.25 0.75 1.25 0.75
F4 SE APARTMENT 1.50 0.00 1.50 0.00
F4 NE APARTMENT 1.50 0.25 1.50 0.25
F4 N1 APARTMENT 2.25 8.25 2.25 8.25
F4 N2 APARTMENT 1.25 10.00 1.25 10.00
F4 S1 APARTMENT 2.50 0.00 2.50 0.00
F4 S2 APARTMENT 1.50 0.00 1.50 0.00
M SW APARTMENT 1.50 0.00 1.50 0.00
M NW APARTMENT 2.75 1.00 2.75 1.00
M SE APARTMENT 2.25 0.00 2.25 0.00
M NE APARTMENT 2.25 0.75 2.25 0.75
M N1 APARTMENT 2.00 10.00 2.00 10.00
M N2 APARTMENT 1.25 11.25 1.25 11.25
M S1 APARTMENT 4.00 0.00 4.00 0.00
M S2 APARTMENT 4.00 0.00 4.00 0.00
F6 SW APARTMENT 1.00 0.00 1.00 0.00
F6 NW APARTMENT 1.25 1.50 1.25 1.50
F6 SE APARTMENT 1.50 0.00 1.50 0.00
F6 NE APARTMENT 1.50 1.00 1.50 1.00
F6 N1 APARTMENT 0.75 10.75 0.75 10.75
F6 N2 APARTMENT 0.50 11.50 0.50 11.50
F6 S1 APARTMENT 2.25 0.00 2.25 0.00
F6 S2 APARTMENT 4.00 0.00 4.00 0.00
F7 SW APARTMENT 1.00 0.00 1.00 0.00
F7 NW APARTMENT 1.50 1.75 1.50 1.75
F7 SE APARTMENT 0.75 0.00 0.75 0.00
F7 NE APARTMENT 3.25 1.75 3.25 1.75
F7 N1 APARTMENT 1.00 11.25 1.00 11.25
F7 N2 APARTMENT 1.50 12.25 1.50 12.25
F7 S1 APARTMENT 2.50 0.00 2.50 0.00
F7 S2 APARTMENT 2.00 0.00 2.00 0.00
F8 SW APARTMENT 1.00 0.00 1.00 0.00
F8 NW APARTMENT 1.50 1.75 1.50 1.75
F8 SE APARTMENT 0.75 0.00 0.75 0.00
F8 NE APARTMENT 3.25 2.25 3.25 2.25
F8 N1 APARTMENT 1.00 11.25 1.00 11.25
F8 N2 APARTMENT 0.25 12.00 0.25 12.00
F8 S1 APARTMENT 2.00 0.00 2.00 0.00
F8 S2 APARTMENT 3.00 0.00 3.00 0.00
F9 SW APARTMENT 1.00 0.00 1.00 0.00
F9 NW APARTMENT 1.00 1.75 1.00 1.75
F9 SE APARTMENT 0.75 0.00 0.75 0.00
F9 NE APARTMENT 2.50 3.25 2.50 3.25
F9 N1 APARTMENT 0.50 10.50 0.50 10.50
F9 N2 APARTMENT 1.50 11.25 1.50 11.25
F9 S1 APARTMENT 1.75 0.00 1.75 0.00
F9 S2 APARTMENT 2.25 0.00 2.25 0.00
T SW APARTMENT 0.50 0.00 0.50 0.00
T NW APARTMENT 0.25 0.75 0.25 0.75
T SE APARTMENT 0.25 0.00 0.25 0.00
T NE APARTMENT 0.00 0.50 0.00 0.50
T N1 APARTMENT 6.25 28.25 6.25 28.25
T N2 APARTMENT 4.25 24.75 4.25 24.75
T S1 APARTMENT 1.25 0.00 1.25 0.00
T S2 APARTMENT 1.00 0.00 1.00 0.00
G CORRIDOR 0.00 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
Facility 117.00 28.25 115.25 28.25
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.355 0.114 0.000 0.190
G NW APARTMENT 1.71 2.50 268.96 0.355 0.114 0.000 0.183
OFFICE 0.94 1.00 268.96 0.520 0.110 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.355 0.114 0.000 0.186
G N1 APARTMENT 1.71 2.50 268.96 0.355 0.069 0.000 0.179
G N2 APARTMENT 1.71 2.50 268.97 0.355 0.069 0.000 0.180
G S1 APARTMENT 1.71 2.50 268.96 0.355 0.069 0.000 0.188
G S2 APARTMENT 1.71 2.50 268.97 0.355 0.069 0.000 0.188
F2 SW APARTMENT 1.71 2.50 268.96 0.355 0.164 0.000 0.213
F2 NW APARTMENT 1.71 2.50 268.96 0.355 0.164 0.000 0.208
F2 SE APARTMENT 1.71 2.50 268.96 0.355 0.164 0.000 0.214
F2 NE APARTMENT 1.71 2.50 268.96 0.355 0.164 0.000 0.210
F2 N1 APARTMENT 1.71 2.50 268.96 0.355 0.099 0.000 0.205
F2 N2 APARTMENT 1.71 2.50 268.97 0.355 0.099 0.000 0.205
F2 S1 APARTMENT 1.71 2.50 268.96 0.355 0.099 0.000 0.212
F2 S2 APARTMENT 1.71 2.50 268.97 0.355 0.099 0.000 0.212
F3 SW APARTMENT 1.71 2.50 268.96 0.355 0.194 0.000 0.226
F3 NW APARTMENT 1.71 2.50 268.96 0.355 0.194 0.000 0.222
F3 SE APARTMENT 1.71 2.50 268.96 0.355 0.194 0.000 0.226
F3 NE APARTMENT 1.71 2.50 268.96 0.355 0.194 0.000 0.224
F3 N1 APARTMENT 1.71 2.50 268.96 0.355 0.117 0.000 0.219
F3 N2 APARTMENT 1.71 2.50 268.97 0.355 0.117 0.000 0.219
F3 S1 APARTMENT 1.71 2.50 268.96 0.355 0.117 0.000 0.225
F3 S2 APARTMENT 1.71 2.50 268.97 0.355 0.117 0.000 0.225
F4 SW APARTMENT 1.71 2.50 268.96 0.355 0.217 0.000 0.224
F4 NW APARTMENT 1.71 2.50 268.96 0.355 0.217 0.000 0.222
F4 SE APARTMENT 1.71 2.50 268.96 0.355 0.217 0.000 0.225
F4 NE APARTMENT 1.71 2.50 268.96 0.355 0.217 0.000 0.223
F4 N1 APARTMENT 1.71 2.50 268.96 0.355 0.131 0.000 0.219
F4 N2 APARTMENT 1.71 2.50 268.97 0.355 0.131 0.000 0.219
F4 S1 APARTMENT 1.71 2.50 268.96 0.355 0.131 0.000 0.224
F4 S2 APARTMENT 1.71 2.50 268.97 0.355 0.131 0.000 0.224
M SW APARTMENT 1.71 2.50 268.96 0.355 0.236 0.000 0.232
M NW APARTMENT 1.71 2.50 268.96 0.355 0.236 0.000 0.230
M SE APARTMENT 1.71 2.50 268.96 0.355 0.236 0.000 0.233
M NE APARTMENT 1.71 2.50 268.96 0.355 0.236 0.000 0.231
M N1 APARTMENT 1.71 2.50 268.96 0.355 0.142 0.000 0.227
M N2 APARTMENT 1.71 2.50 268.97 0.355 0.142 0.000 0.228
M S1 APARTMENT 1.71 2.50 268.96 0.355 0.142 0.000 0.232
M S2 APARTMENT 1.71 2.50 268.97 0.355 0.142 0.000 0.232
F6 SW APARTMENT 1.71 2.50 268.96 0.355 0.252 0.000 0.239
F6 NW APARTMENT 1.71 2.50 268.96 0.355 0.252 0.000 0.237
F6 SE APARTMENT 1.71 2.50 268.96 0.355 0.252 0.000 0.240
F6 NE APARTMENT 1.71 2.50 268.96 0.355 0.252 0.000 0.238
F6 N1 APARTMENT 1.71 2.50 268.96 0.355 0.152 0.000 0.234
F6 N2 APARTMENT 1.71 2.50 268.97 0.355 0.152 0.000 0.234
F6 S1 APARTMENT 1.71 2.50 268.96 0.355 0.152 0.000 0.239
F6 S2 APARTMENT 1.71 2.50 268.97 0.355 0.152 0.000 0.239
F7 SW APARTMENT 1.71 2.50 268.96 0.355 0.267 0.000 0.245
F7 NW APARTMENT 1.71 2.50 268.96 0.355 0.266 0.000 0.243
F7 SE APARTMENT 1.71 2.50 268.96 0.355 0.267 0.000 0.246
F7 NE APARTMENT 1.71 2.50 268.96 0.355 0.266 0.000 0.244
F7 N1 APARTMENT 1.71 2.50 268.96 0.355 0.161 0.000 0.240
F7 N2 APARTMENT 1.71 2.50 268.97 0.355 0.161 0.000 0.240
F7 S1 APARTMENT 1.71 2.50 268.96 0.355 0.161 0.000 0.245
F7 S2 APARTMENT 1.71 2.50 268.97 0.355 0.161 0.000 0.245
F8 SW APARTMENT 1.71 2.50 268.96 0.355 0.279 0.000 0.251
F8 NW APARTMENT 1.71 2.50 268.96 0.355 0.279 0.000 0.248
F8 SE APARTMENT 1.71 2.50 268.96 0.355 0.279 0.000 0.252
F8 NE APARTMENT 1.71 2.50 268.96 0.355 0.279 0.000 0.249
F8 N1 APARTMENT 1.71 2.50 268.96 0.355 0.168 0.000 0.245
F8 N2 APARTMENT 1.71 2.50 268.97 0.355 0.168 0.000 0.246
F8 S1 APARTMENT 1.71 2.50 268.96 0.355 0.169 0.000 0.250
F8 S2 APARTMENT 1.71 2.50 268.97 0.355 0.169 0.000 0.250
F9 SW APARTMENT 1.71 2.50 268.96 0.355 0.291 0.000 0.257
F9 NW APARTMENT 1.71 2.50 268.96 0.354 0.291 0.000 0.254
F9 SE APARTMENT 1.71 2.50 268.96 0.355 0.291 0.000 0.257
F9 NE APARTMENT 1.71 2.50 268.96 0.354 0.291 0.000 0.255
F9 N1 APARTMENT 1.71 2.50 268.96 0.355 0.175 0.000 0.251
F9 N2 APARTMENT 1.71 2.50 268.97 0.355 0.175 0.000 0.251
F9 S1 APARTMENT 1.71 2.50 268.96 0.355 0.176 0.000 0.256
F9 S2 APARTMENT 1.71 2.50 268.97 0.355 0.176 0.000 0.256
T SW APARTMENT 1.71 2.50 268.96 0.355 0.302 0.000 0.260
T NW APARTMENT 1.71 2.50 268.96 0.354 0.302 0.000 0.258
T SE APARTMENT 1.71 2.50 268.96 0.355 0.302 0.000 0.261
T NE APARTMENT 1.71 2.50 268.96 0.354 0.302 0.000 0.259
T N1 APARTMENT 1.71 2.50 268.96 0.355 0.182 0.000 0.255
T N2 APARTMENT 1.71 2.50 268.97 0.355 0.182 0.000 0.255
T S1 APARTMENT 1.71 2.50 268.96 0.355 0.182 0.000 0.260
T S2 APARTMENT 1.71 2.50 268.97 0.355 0.182 0.000 0.260
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
OFFICE 0.94 1.00 268.96 0.503 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F2 SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F2 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F2 SE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F2 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F2 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F2 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F2 S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F2 S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F3 SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F3 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F3 SE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F3 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F3 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F3 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F3 S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F3 S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F4 SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F4 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F4 SE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F4 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F4 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F4 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F4 S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F4 S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F6 SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F6 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F6 SE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F6 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F6 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F6 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F6 S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F6 S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F7 SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F7 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F7 SE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F7 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F7 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F7 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F7 S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F7 S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F8 SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F8 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F8 SE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F8 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F8 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F8 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F8 S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F8 S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F9 SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F9 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F9 SE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F9 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F9 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F9 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F9 S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F9 S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Surfaces by Class

Total Outdoors
Wall 420 140
Floor 90 9
Roof 90 9
Internal Mass 80 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 140 140
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 80
Conditioned Zones 80
Unconditioned Zones 10
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 4156
Defaulted Fields 814
Fields with Defaults 11184
Autosized Fields 1293
Autosizable Fields 1630
Autocalculated Fields 907
Autocalculatable Fields 1710



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 3157.51 47645.33 03-JUL-02:45 332168.45 28-JAN-24:00
Electricity:Building 1433.88 25760.85 01-JAN-03:15 70162.48 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity 296.56 6715.87 01-JAN-00:15 14401.37 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 242.55 5824.91 01-JAN-00:15 11484.27 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:OFFICE 39.38 663.42 01-JAN-00:15 2934.49 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 29.88 469.18 01-JAN-00:15 2345.88 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:G CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F2 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F2 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F3 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F3 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F4 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F4 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:M SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M CORRIDOR 32.88 1042.61 01-JAN-00:15 1042.61 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 32.88 1042.61 01-JAN-00:15 1042.61 01-JAN-00:15
Electricity:Zone:F6 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F6 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F7 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F7 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F8 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F8 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F9 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F9 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:T SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T CORRIDOR 179.47 1701.70 01-JAN-00:15 10868.20 01-JAN-07:15
InteriorLights:Electricity:Zone:T CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 54.01 890.97 01-JAN-00:15 2917.11 01-JAN-19:15
InteriorEquipment:Electricity 1137.32 19044.98 01-JAN-03:15 57142.09 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 1137.32 19044.98 01-JAN-03:15 57142.09 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 9.50 194.24 01-JAN-00:15 588.62 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T CORRIDOR 163.03 1180.40 01-JAN-00:15 10346.90 01-JAN-07:15
Fans:Electricity 668.13 21186.30 01-JAN-00:15 21186.30 01-JAN-00:15
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Electricity:HVAC 1502.13 21847.55 03-JUL-02:30 283199.94 28-JAN-24:00
ElectricityProduced:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityProduced:HVAC 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricityProduced 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 3157.51 47645.33 03-JUL-02:45 332168.45 28-JAN-24:00
ElectricityPurchased:Plant 3157.51 47645.33 03-JUL-02:45 332168.45 28-JAN-24:00
Cogeneration:ElectricityPurchased 3157.51 47645.33 03-JUL-02:45 332168.45 28-JAN-24:00
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 3157.51 47645.33 03-JUL-02:45 332168.45 28-JAN-24:00
ElectricityNet:Plant 3157.51 47645.33 03-JUL-02:45 332168.45 28-JAN-24:00
Cogeneration:ElectricityNet 3157.51 47645.33 03-JUL-02:45 332168.45 28-JAN-24:00
ExteriorLights:Electricity 161.58 0.00 01-JAN-11:30 10364.00 01-JAN-00:15
General:ExteriorLights:Electricity 161.58 0.00 01-JAN-11:30 10364.00 01-JAN-00:15
General:Fans:Electricity 668.13 21186.30 01-JAN-00:15 21186.30 01-JAN-00:15
Cooling:Electricity 123.96 0.00 01-JAN-00:15 59159.15 21-JUL-14:15
Heating:Electricity 673.86 0.00 17-APR-13:45 261078.47 28-JAN-24:00
Electricity:Plant 59.92 36.93 17-APR-19:15 3756.57 29-JUL-16:15
HeatRejection:Electricity 4.75 0.00 01-JAN-00:15 2000.14 29-JUL-16:15
Boiler Parasitic:Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Pumps:Electricity 55.17 36.93 17-APR-19:15 1756.43 01-JAN-00:15
WIRED_LTG_ELECTRICITY 0.44 0.00 01-JAN-00:15 21.60 01-JAN-19:30
WIRED_INT_EQUIP 979.40 1018.50 01-JAN-00:15 10185.00 01-JAN-07:15


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 3817.79 2357.00 13-APR-23:30 344253.99 29-JAN-08:00
Gas:Plant 3817.79 2357.00 13-APR-23:30 344253.99 29-JAN-08:00
WaterSystems:Gas 1467.86 2357.00 01-JAN-00:15 91426.54 13-MAR-07:00
Water Heater:WaterSystems:Gas 1467.86 2357.00 01-JAN-00:15 91426.54 13-MAR-07:00
Heating:Gas 2349.92 0.00 20-MAR-13:00 265464.84 29-JAN-00:45
Boiler:Heating:Gas 2349.92 0.00 20-MAR-13:00 265464.84 29-JAN-00:45


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
PlantLoopCoolingDemand:Facility 478.22 0.00 01-JAN-00:15 256470.00 30-JUN-12:30
PlantLoopCoolingDemand:HVAC 478.22 0.00 01-JAN-00:15 256470.00 30-JUN-12:30
CoolingCoils:PlantLoopCoolingDemand 478.22 0.00 01-JAN-00:15 256470.00 30-JUN-12:30


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 5205.26 0.00 01-JAN-02:15 0.00 29-JUL-17:15
Water:Plant 5205.26 0.00 01-JAN-02:15 0.00 29-JUL-17:15
WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
MainsWater:Facility 5205.26 0.00 01-JAN-02:15 0.00 29-JUL-17:15
MainsWater:Plant 5205.26 0.00 01-JAN-02:15 0.00 29-JUL-17:15
WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
sub cat:WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
sub cat:WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
HeatRejection:Water 426.74 0.00 01-JAN-00:15 0.00 21-JUL-16:00
HeatRejection:MainsWater 426.74 0.00 01-JAN-00:15 0.00 21-JUL-16:00


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 2948.45 648.32 18-AUG-01:30 263893.59 29-JAN-08:00
PlantLoopHeatingDemand:Plant 1146.99 643.92 10-SEP-01:30 71343.61 12-DEC-07:45
WaterSystems:PlantLoopHeatingDemand 1146.99 643.92 10-SEP-01:30 71343.61 12-DEC-07:45
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 7531.77 6250.24 08-AUG-01:15 1045645.47 28-JAN-24:00
EnergyTransfer:Building 1811.91 4002.68 18-JUN-17:00 364683.21 28-JAN-24:00
EnergyTransfer:Zone:G SW APARTMENT 25.50 0.03 02-SEP-16:30 3812.46 28-JAN-24:00
Heating:EnergyTransfer 1330.03 0.00 22-MAR-16:15 364683.21 28-JAN-24:00
Heating:EnergyTransfer:Zone:G SW APARTMENT 21.59 0.00 09-FEB-11:45 3812.46 28-JAN-24:00
Cooling:EnergyTransfer 481.88 0.00 01-JAN-00:15 175298.29 11-JUL-16:15
Cooling:EnergyTransfer:Zone:G SW APARTMENT 3.91 0.00 01-JAN-00:15 2330.98 11-AUG-16:15
EnergyTransfer:Zone:G NW APARTMENT 27.35 0.06 02-JUL-19:45 3879.07 28-JAN-24:00
Heating:EnergyTransfer:Zone:G NW APARTMENT 25.07 0.00 22-MAR-15:15 3879.07 28-JAN-24:00
Cooling:EnergyTransfer:Zone:G NW APARTMENT 2.28 0.00 01-JAN-00:15 1906.10 11-JUL-17:45
EnergyTransfer:Zone:OFFICE 28.81 0.01 24-SEP-18:30 3833.06 28-JAN-24:00
Heating:EnergyTransfer:Zone:OFFICE 16.80 0.00 17-JAN-11:30 3833.06 28-JAN-24:00
Cooling:EnergyTransfer:Zone:OFFICE 12.01 0.00 01-JAN-00:15 3672.07 10-AUG-13:45
EnergyTransfer:Zone:G NE APARTMENT 27.12 0.02 22-JUN-21:00 3886.95 28-JAN-24:00
Heating:EnergyTransfer:Zone:G NE APARTMENT 24.54 0.00 20-MAR-09:45 3886.95 28-JAN-24:00
Cooling:EnergyTransfer:Zone:G NE APARTMENT 2.58 0.00 01-JAN-00:15 1388.83 11-JUL-05:30
EnergyTransfer:Zone:G N1 APARTMENT 18.58 0.02 16-JUL-10:15 2435.98 29-JAN-00:15
Heating:EnergyTransfer:Zone:G N1 APARTMENT 16.17 0.00 22-MAR-16:15 2435.98 29-JAN-00:15
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 2.41 0.00 01-JAN-00:15 1018.53 11-JUL-17:30
EnergyTransfer:Zone:G N2 APARTMENT 18.57 0.01 03-JUL-18:45 2436.10 29-JAN-00:15
Heating:EnergyTransfer:Zone:G N2 APARTMENT 16.14 0.00 22-MAR-16:15 2436.10 29-JAN-00:15
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 2.43 0.00 01-JAN-00:15 1014.47 11-JUL-17:30
EnergyTransfer:Zone:G S1 APARTMENT 17.03 0.00 16-AUG-12:45 2345.02 29-JAN-00:15
Heating:EnergyTransfer:Zone:G S1 APARTMENT 12.69 0.00 09-FEB-11:15 2345.02 29-JAN-00:15
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 4.35 0.00 01-JAN-00:15 1846.91 21-JUL-14:15
EnergyTransfer:Zone:G S2 APARTMENT 16.92 0.01 02-JUL-19:45 2339.45 29-JAN-00:15
Heating:EnergyTransfer:Zone:G S2 APARTMENT 12.40 0.00 09-FEB-11:15 2339.45 29-JAN-00:15
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 4.52 0.00 01-JAN-00:15 1909.96 21-JUL-14:15
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F2 SW APARTMENT 25.11 0.00 26-JUN-03:45 4440.65 28-JAN-24:00
Heating:EnergyTransfer:Zone:F2 SW APARTMENT 17.58 0.00 09-FEB-11:30 4440.65 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT 7.53 0.00 01-JAN-00:15 3131.67 11-AUG-16:15
EnergyTransfer:Zone:F2 NW APARTMENT 25.46 0.09 26-JUL-16:45 4567.23 28-JAN-24:00
Heating:EnergyTransfer:Zone:F2 NW APARTMENT 21.55 0.00 18-MAR-15:15 4567.23 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT 3.91 0.00 01-JAN-00:15 2499.14 11-JUL-17:30
EnergyTransfer:Zone:F2 SE APARTMENT 26.02 0.05 06-AUG-12:00 4431.19 28-JAN-24:00
Heating:EnergyTransfer:Zone:F2 SE APARTMENT 16.23 0.00 09-FEB-11:15 4431.19 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT 9.78 0.00 01-JAN-00:15 3318.73 21-JUL-14:15
EnergyTransfer:Zone:F2 NE APARTMENT 25.77 0.00 16-JUL-12:30 4581.18 28-JAN-24:00
Heating:EnergyTransfer:Zone:F2 NE APARTMENT 20.91 0.00 18-MAR-12:15 4581.18 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT 4.86 0.00 01-JAN-00:15 1993.08 11-JUL-16:30
EnergyTransfer:Zone:F2 N1 APARTMENT 14.89 0.02 22-MAY-16:00 2662.24 29-JAN-00:15
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT 10.73 0.00 07-FEB-21:00 2662.24 29-JAN-00:15
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT 4.16 0.00 01-JAN-00:15 1280.01 11-JUL-16:15
EnergyTransfer:Zone:F2 N2 APARTMENT 14.91 0.00 07-JUN-15:45 2662.42 29-JAN-00:15
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT 10.70 0.00 07-FEB-21:00 2662.42 29-JAN-00:15
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT 4.20 0.00 01-JAN-00:15 1264.84 11-JUL-16:15
EnergyTransfer:Zone:F2 S1 APARTMENT 15.81 0.03 21-JAN-21:15 2535.29 29-JAN-00:15
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT 7.80 0.00 16-JAN-13:00 2535.29 29-JAN-00:15
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT 8.01 0.00 01-JAN-00:15 2507.10 21-JUL-14:15
EnergyTransfer:Zone:F2 S2 APARTMENT 15.91 0.10 21-MAR-23:30 2533.91 21-JUL-14:15
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT 7.73 0.00 16-JAN-13:00 2533.57 29-JAN-00:15
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT 8.18 0.00 01-JAN-00:15 2533.91 21-JUL-14:15
EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F3 SW APARTMENT 25.11 0.09 25-JUN-00:15 4853.48 28-JAN-24:00
Heating:EnergyTransfer:Zone:F3 SW APARTMENT 16.88 0.00 23-JAN-13:00 4853.48 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT 8.23 0.00 01-JAN-00:15 3200.17 11-AUG-16:15
EnergyTransfer:Zone:F3 NW APARTMENT 25.17 0.00 30-APR-03:15 4985.76 28-JAN-24:00
Heating:EnergyTransfer:Zone:F3 NW APARTMENT 20.86 0.00 18-MAR-12:45 4985.76 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT 4.30 0.00 01-JAN-00:15 2536.78 11-JUL-17:15
EnergyTransfer:Zone:F3 SE APARTMENT 26.05 0.10 29-MAY-13:00 4865.00 28-JAN-24:00
Heating:EnergyTransfer:Zone:F3 SE APARTMENT 16.38 0.00 23-JAN-12:45 4865.00 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT 9.68 0.00 01-JAN-00:15 3321.35 22-JUL-12:00
EnergyTransfer:Zone:F3 NE APARTMENT 25.56 0.12 07-JUN-11:15 5002.13 28-JAN-24:00
Heating:EnergyTransfer:Zone:F3 NE APARTMENT 20.25 0.00 18-MAR-09:30 5002.13 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT 5.31 0.00 01-JAN-00:15 2085.89 13-JUN-06:45
EnergyTransfer:Zone:F3 N1 APARTMENT 14.23 0.03 09-AUG-12:00 2856.30 28-JAN-24:00
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT 9.61 0.00 21-JAN-20:45 2856.30 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT 4.61 0.00 01-JAN-00:15 1361.79 29-JUN-19:15
EnergyTransfer:Zone:F3 N2 APARTMENT 14.24 0.01 13-MAY-19:00 2856.50 28-JAN-24:00
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT 9.58 0.00 21-JAN-20:45 2856.50 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT 4.66 0.00 01-JAN-00:15 1346.62 29-JUN-19:15
EnergyTransfer:Zone:F3 S1 APARTMENT 15.95 0.50 07-APR-07:45 2719.67 28-JAN-24:00
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT 6.81 0.00 16-JAN-12:45 2719.67 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT 9.15 0.00 01-JAN-00:15 2585.26 21-JUL-14:15
EnergyTransfer:Zone:F3 S2 APARTMENT 16.03 0.02 27-FEB-13:30 2719.34 28-JAN-24:00
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT 6.78 0.00 16-JAN-12:45 2719.34 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT 9.25 0.00 01-JAN-00:15 2602.87 21-JUL-14:15
EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F4 SW APARTMENT 25.62 0.09 06-JUN-00:15 5253.56 28-JAN-24:00
Heating:EnergyTransfer:Zone:F4 SW APARTMENT 17.34 0.00 23-JAN-12:45 5253.56 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT 8.28 0.00 01-JAN-00:15 3223.10 11-JUL-17:30
EnergyTransfer:Zone:F4 NW APARTMENT 25.75 0.00 03-AUG-20:45 5389.10 28-JAN-24:00
Heating:EnergyTransfer:Zone:F4 NW APARTMENT 21.41 0.00 18-MAR-12:15 5389.10 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT 4.34 0.00 01-JAN-00:15 2538.42 11-JUL-17:15
EnergyTransfer:Zone:F4 SE APARTMENT 26.55 0.03 25-JUN-13:30 5270.20 28-JAN-24:00
Heating:EnergyTransfer:Zone:F4 SE APARTMENT 16.95 0.00 23-JAN-12:30 5270.20 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT 9.60 0.00 01-JAN-00:15 3335.19 22-JUL-12:00
EnergyTransfer:Zone:F4 NE APARTMENT 26.16 0.02 18-JUL-10:30 5407.06 28-JAN-24:00
Heating:EnergyTransfer:Zone:F4 NE APARTMENT 20.80 0.00 18-MAR-09:30 5407.06 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT 5.37 0.00 01-JAN-00:15 2133.19 13-JUN-07:00
EnergyTransfer:Zone:F4 N1 APARTMENT 14.45 0.00 02-JUN-15:45 3089.35 28-JAN-24:00
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT 9.73 0.00 21-JAN-20:45 3089.35 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT 4.72 0.00 01-JAN-00:15 1373.43 29-JUN-19:30
EnergyTransfer:Zone:F4 N2 APARTMENT 14.48 0.00 11-MAY-16:30 3089.58 28-JAN-24:00
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT 9.70 0.00 21-JAN-20:45 3089.58 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT 4.78 0.00 01-JAN-00:15 1357.93 29-JUN-19:30
EnergyTransfer:Zone:F4 S1 APARTMENT 16.26 0.00 11-OCT-16:00 2948.96 28-JAN-24:00
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT 6.87 0.00 16-JAN-12:45 2948.96 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT 9.39 0.00 01-JAN-00:15 2607.10 21-JUL-14:15
EnergyTransfer:Zone:F4 S2 APARTMENT 16.33 0.05 06-APR-05:15 2949.03 28-JAN-24:00
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT 6.86 0.00 16-JAN-12:45 2949.03 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT 9.47 0.00 01-JAN-00:15 2623.55 21-JUL-14:15
EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M SW APARTMENT 25.90 0.09 28-MAY-22:45 5579.14 28-JAN-24:00
Heating:EnergyTransfer:Zone:M SW APARTMENT 17.71 0.00 23-JAN-12:45 5579.14 28-JAN-24:00
Cooling:EnergyTransfer:Zone:M SW APARTMENT 8.19 0.00 01-JAN-00:15 3262.34 11-JUL-17:30
EnergyTransfer:Zone:M NW APARTMENT 26.10 0.05 17-MAY-14:00 5715.36 28-JAN-24:00
Heating:EnergyTransfer:Zone:M NW APARTMENT 21.78 0.00 18-MAR-11:30 5715.36 28-JAN-24:00
Cooling:EnergyTransfer:Zone:M NW APARTMENT 4.32 0.00 01-JAN-00:15 2558.95 11-JUL-17:15
EnergyTransfer:Zone:M SE APARTMENT 26.80 0.05 26-JUN-02:00 5597.45 28-JAN-24:00
Heating:EnergyTransfer:Zone:M SE APARTMENT 17.33 0.00 23-JAN-12:15 5597.45 28-JAN-24:00
Cooling:EnergyTransfer:Zone:M SE APARTMENT 9.47 0.00 01-JAN-00:15 3368.32 22-JUL-12:00
EnergyTransfer:Zone:M NE APARTMENT 26.51 0.01 20-MAR-18:45 5734.43 28-JAN-24:00
Heating:EnergyTransfer:Zone:M NE APARTMENT 21.17 0.00 18-MAR-08:00 5734.43 28-JAN-24:00
Cooling:EnergyTransfer:Zone:M NE APARTMENT 5.34 0.00 01-JAN-00:15 2157.11 13-JUN-07:00
EnergyTransfer:Zone:M N1 APARTMENT 14.55 0.08 11-MAY-14:00 3277.05 28-JAN-24:00
Heating:EnergyTransfer:Zone:M N1 APARTMENT 9.78 0.00 19-JAN-19:00 3277.05 28-JAN-24:00
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 4.77 0.00 01-JAN-00:15 1401.83 29-JUN-19:30
EnergyTransfer:Zone:M N2 APARTMENT 14.57 0.06 01-AUG-14:30 3277.29 28-JAN-24:00
Heating:EnergyTransfer:Zone:M N2 APARTMENT 9.75 0.00 19-JAN-19:00 3277.29 28-JAN-24:00
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 4.82 0.00 01-JAN-00:15 1385.88 29-JUN-19:30
EnergyTransfer:Zone:M S1 APARTMENT 16.36 0.10 20-OCT-10:30 3136.02 28-JAN-24:00
Heating:EnergyTransfer:Zone:M S1 APARTMENT 6.94 0.00 16-JAN-12:45 3136.02 28-JAN-24:00
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 9.42 0.00 01-JAN-00:15 2639.30 21-JUL-14:15
EnergyTransfer:Zone:M S2 APARTMENT 16.43 0.17 28-FEB-20:00 3136.18 28-JAN-24:00
Heating:EnergyTransfer:Zone:M S2 APARTMENT 6.93 0.00 16-JAN-12:45 3136.18 28-JAN-24:00
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 9.50 0.00 01-JAN-00:15 2655.54 21-JUL-14:15
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F6 SW APARTMENT 26.38 0.06 06-JUN-00:45 5913.53 28-JAN-24:00
Heating:EnergyTransfer:Zone:F6 SW APARTMENT 18.84 0.00 23-JAN-12:45 5913.53 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT 7.54 0.00 01-JAN-00:15 3237.11 11-JUL-17:30
EnergyTransfer:Zone:F6 NW APARTMENT 26.98 0.06 19-SEP-13:45 6051.56 28-JAN-24:00
Heating:EnergyTransfer:Zone:F6 NW APARTMENT 23.05 0.00 18-MAR-12:15 6051.56 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT 3.93 0.00 01-JAN-00:15 2513.01 11-JUL-17:15
EnergyTransfer:Zone:F6 SE APARTMENT 27.24 0.05 18-AUG-19:00 5932.84 28-JAN-24:00
Heating:EnergyTransfer:Zone:F6 SE APARTMENT 18.45 0.00 23-JAN-12:30 5932.84 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT 8.79 0.00 01-JAN-00:15 3340.70 22-JUL-12:00
EnergyTransfer:Zone:F6 NE APARTMENT 27.33 0.03 18-JUN-18:15 6071.52 28-JAN-24:00
Heating:EnergyTransfer:Zone:F6 NE APARTMENT 22.42 0.00 18-MAR-08:30 6071.52 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT 4.91 0.00 01-JAN-00:15 2118.35 13-JUN-07:00
EnergyTransfer:Zone:F6 N1 APARTMENT 15.05 0.03 21-AUG-15:00 3491.88 28-JAN-24:00
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT 10.63 0.00 21-JAN-20:45 3491.88 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT 4.42 0.00 01-JAN-00:15 1360.91 29-JUN-19:30
EnergyTransfer:Zone:F6 N2 APARTMENT 15.07 0.01 04-JUN-18:15 3492.13 28-JAN-24:00
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT 10.60 0.00 21-JAN-20:45 3492.13 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT 4.46 0.00 01-JAN-00:15 1344.13 29-JUN-19:30
EnergyTransfer:Zone:F6 S1 APARTMENT 16.35 0.00 16-OCT-13:00 3348.75 28-JAN-24:00
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT 7.61 0.00 16-JAN-12:45 3348.75 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT 8.74 0.00 01-JAN-00:15 2606.80 21-JUL-14:15
EnergyTransfer:Zone:F6 S2 APARTMENT 16.42 0.02 12-FEB-24:00 3348.95 28-JAN-24:00
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT 7.60 0.00 16-JAN-12:45 3348.95 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT 8.82 0.00 01-JAN-00:15 2623.15 21-JUL-14:15
EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F7 SW APARTMENT 26.79 0.01 15-AUG-03:15 6195.62 28-JAN-24:00
Heating:EnergyTransfer:Zone:F7 SW APARTMENT 19.68 0.00 23-JAN-13:00 6195.62 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT 7.11 0.00 01-JAN-00:15 3230.95 11-JUL-17:30
EnergyTransfer:Zone:F7 NW APARTMENT 27.64 0.03 19-MAY-13:00 6333.99 28-JAN-24:00
Heating:EnergyTransfer:Zone:F7 NW APARTMENT 23.96 0.00 18-MAR-12:30 6333.99 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT 3.68 0.00 01-JAN-00:15 2492.27 11-JUL-17:15
EnergyTransfer:Zone:F7 SE APARTMENT 27.60 0.02 15-JUN-02:15 6215.66 28-JAN-24:00
Heating:EnergyTransfer:Zone:F7 SE APARTMENT 19.27 0.00 23-JAN-13:00 6215.66 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT 8.33 0.00 01-JAN-00:15 3334.31 22-JUL-12:00
EnergyTransfer:Zone:F7 NE APARTMENT 27.96 0.00 06-SEP-04:30 6172.81 28-JAN-24:00
Heating:EnergyTransfer:Zone:F7 NE APARTMENT 23.32 0.00 18-MAR-09:15 6172.81 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT 4.64 0.00 01-JAN-00:15 2100.14 13-JUN-07:00
EnergyTransfer:Zone:F7 N1 APARTMENT 15.40 0.00 04-JUN-17:45 3668.24 28-JAN-24:00
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT 11.21 0.00 21-JAN-21:00 3668.24 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT 4.19 0.00 01-JAN-00:15 1344.17 29-JUN-19:45
EnergyTransfer:Zone:F7 N2 APARTMENT 15.41 0.02 02-OCT-09:45 3668.53 28-JAN-24:00
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT 11.18 0.00 21-JAN-21:00 3668.53 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT 4.23 0.00 01-JAN-00:15 1328.79 29-JUN-19:45
EnergyTransfer:Zone:F7 S1 APARTMENT 16.38 0.01 07-AUG-23:15 3524.86 28-JAN-24:00
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT 8.09 0.00 16-JAN-12:45 3524.86 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT 8.29 0.00 01-JAN-00:15 2594.79 21-JUL-14:15
EnergyTransfer:Zone:F7 S2 APARTMENT 16.44 0.01 30-OCT-10:15 3525.07 28-JAN-24:00
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT 8.07 0.00 16-JAN-12:45 3525.07 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT 8.37 0.00 01-JAN-00:15 2611.29 21-JUL-14:15
EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F8 SW APARTMENT 27.29 0.01 26-SEP-09:45 6458.40 28-JAN-24:00
Heating:EnergyTransfer:Zone:F8 SW APARTMENT 20.55 0.00 23-JAN-13:00 6458.40 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT 6.74 0.00 01-JAN-00:15 3233.39 11-JUL-17:30
EnergyTransfer:Zone:F8 NW APARTMENT 28.41 0.01 04-MAY-04:30 6596.95 28-JAN-24:00
Heating:EnergyTransfer:Zone:F8 NW APARTMENT 24.90 0.00 18-MAR-13:00 6596.95 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT 3.50 0.00 01-JAN-00:15 2485.17 11-JUL-17:15
EnergyTransfer:Zone:F8 SE APARTMENT 28.07 0.07 13-FEB-10:30 6479.07 28-JAN-24:00
Heating:EnergyTransfer:Zone:F8 SE APARTMENT 20.13 0.00 23-JAN-12:45 6479.07 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT 7.94 0.00 01-JAN-00:15 3335.82 22-JUL-12:00
EnergyTransfer:Zone:F8 NE APARTMENT 28.68 0.01 14-MAY-10:15 6229.34 28-JAN-24:00
Heating:EnergyTransfer:Zone:F8 NE APARTMENT 24.25 0.00 18-MAR-09:15 6229.34 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT 4.43 0.00 01-JAN-00:15 2091.44 13-JUN-07:00
EnergyTransfer:Zone:F8 N1 APARTMENT 15.86 0.04 10-JUN-12:00 3835.73 28-JAN-24:00
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT 11.85 0.00 21-JAN-21:00 3835.73 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT 4.00 0.00 01-JAN-00:15 1344.66 29-JUN-19:45
EnergyTransfer:Zone:F8 N2 APARTMENT 15.86 0.01 03-AUG-13:45 3836.36 28-JAN-24:00
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT 11.82 0.00 21-JAN-21:00 3836.36 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT 4.04 0.00 01-JAN-00:15 1329.35 29-JUN-19:45
EnergyTransfer:Zone:F8 S1 APARTMENT 16.54 0.04 16-OCT-19:15 3692.38 28-JAN-24:00
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT 8.64 0.00 16-JAN-12:45 3692.38 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT 7.89 0.00 01-JAN-00:15 2591.67 21-JUL-14:15
EnergyTransfer:Zone:F8 S2 APARTMENT 16.60 0.07 28-AUG-19:00 3692.61 28-JAN-24:00
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT 8.63 0.00 16-JAN-12:45 3692.61 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT 7.97 0.00 01-JAN-00:15 2608.45 21-JUL-14:15
EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F9 SW APARTMENT 29.16 0.04 01-OCT-13:00 6813.27 28-JAN-24:00
Heating:EnergyTransfer:Zone:F9 SW APARTMENT 22.83 0.00 09-FEB-11:45 6813.27 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT 6.33 0.00 01-JAN-00:15 3301.56 11-JUL-17:30
EnergyTransfer:Zone:F9 NW APARTMENT 30.69 0.02 11-SEP-17:00 6951.76 28-JAN-24:00
Heating:EnergyTransfer:Zone:F9 NW APARTMENT 27.34 0.00 18-MAR-15:00 6951.76 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT 3.35 0.00 01-JAN-00:15 2554.73 11-JUL-17:15
EnergyTransfer:Zone:F9 SE APARTMENT 29.83 0.07 07-AUG-09:30 6835.02 28-JAN-24:00
Heating:EnergyTransfer:Zone:F9 SE APARTMENT 22.37 0.00 09-FEB-11:30 6835.02 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT 7.47 0.00 01-JAN-00:15 3376.43 22-JUL-12:00
EnergyTransfer:Zone:F9 NE APARTMENT 30.89 0.01 24-JUL-09:45 6511.12 28-JAN-24:00
Heating:EnergyTransfer:Zone:F9 NE APARTMENT 26.64 0.00 18-MAR-11:30 6511.12 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT 4.24 0.00 01-JAN-00:15 2086.47 13-JUN-07:00
EnergyTransfer:Zone:F9 N1 APARTMENT 17.65 0.00 14-JUL-09:30 4093.95 28-JAN-24:00
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT 13.85 0.00 07-FEB-21:00 4093.95 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT 3.79 0.00 01-JAN-00:15 1408.63 29-JUN-19:45
EnergyTransfer:Zone:F9 N2 APARTMENT 17.65 0.00 08-JUL-11:30 4094.80 28-JAN-24:00
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT 13.82 0.00 07-FEB-21:00 4094.80 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT 3.84 0.00 01-JAN-00:15 1392.53 29-JUN-19:45
EnergyTransfer:Zone:F9 S1 APARTMENT 17.70 0.09 25-SEP-00:15 3950.07 28-JAN-24:00
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT 10.37 0.00 16-JAN-13:00 3950.07 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT 7.33 0.00 01-JAN-00:15 2623.54 21-JUL-14:15
EnergyTransfer:Zone:F9 S2 APARTMENT 17.75 0.06 10-JUN-12:30 3950.35 28-JAN-24:00
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT 10.35 0.00 16-JAN-13:00 3950.35 28-JAN-24:00
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT 7.40 0.00 01-JAN-00:15 2642.65 21-JUL-14:15
EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:T SW APARTMENT 38.49 0.00 30-MAY-08:45 7710.36 28-JAN-24:00
Heating:EnergyTransfer:Zone:T SW APARTMENT 32.46 0.00 09-FEB-11:45 7710.36 28-JAN-24:00
Cooling:EnergyTransfer:Zone:T SW APARTMENT 6.03 0.00 01-JAN-00:15 3781.60 20-JUN-16:15
EnergyTransfer:Zone:T NW APARTMENT 39.61 0.01 23-MAY-22:00 7800.04 28-JAN-24:00
Heating:EnergyTransfer:Zone:T NW APARTMENT 36.59 0.00 18-MAR-12:30 7800.04 28-JAN-24:00
Cooling:EnergyTransfer:Zone:T NW APARTMENT 3.01 0.00 01-JAN-00:15 3022.16 11-JUL-17:15
EnergyTransfer:Zone:T SE APARTMENT 38.86 0.00 07-OCT-14:30 7733.03 28-JAN-24:00
Heating:EnergyTransfer:Zone:T SE APARTMENT 31.92 0.00 09-FEB-11:30 7733.03 28-JAN-24:00
Cooling:EnergyTransfer:Zone:T SE APARTMENT 6.94 0.00 01-JAN-00:15 3920.17 22-JUL-12:00
EnergyTransfer:Zone:T NE APARTMENT 39.67 0.03 14-JUL-00:15 7963.49 28-JAN-24:00
Heating:EnergyTransfer:Zone:T NE APARTMENT 35.85 0.00 18-MAR-11:00 7963.49 28-JAN-24:00
Cooling:EnergyTransfer:Zone:T NE APARTMENT 3.83 0.00 01-JAN-00:15 2386.39 22-JUL-12:00
EnergyTransfer:Zone:T N1 APARTMENT 26.10 0.01 25-JUL-17:45 4897.77 28-JAN-24:00
Heating:EnergyTransfer:Zone:T N1 APARTMENT 22.84 0.00 18-MAR-11:15 4897.77 28-JAN-24:00
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 3.26 0.00 01-JAN-00:15 1565.17 29-JUN-19:30
EnergyTransfer:Zone:T N2 APARTMENT 26.11 0.07 30-MAY-13:45 4938.50 28-JAN-24:00
Heating:EnergyTransfer:Zone:T N2 APARTMENT 22.80 0.00 18-MAR-10:45 4938.50 28-JAN-24:00
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 3.31 0.00 01-JAN-00:15 1588.66 29-JUN-19:30
EnergyTransfer:Zone:T S1 APARTMENT 25.54 0.01 18-AUG-19:15 4800.50 28-JAN-24:00
Heating:EnergyTransfer:Zone:T S1 APARTMENT 19.21 0.00 23-JAN-12:30 4800.50 28-JAN-24:00
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 6.32 0.00 01-JAN-00:15 3275.20 21-JUL-14:15
EnergyTransfer:Zone:T S2 APARTMENT 25.58 0.01 05-OCT-17:00 4800.95 28-JAN-24:00
Heating:EnergyTransfer:Zone:T S2 APARTMENT 19.19 0.00 23-JAN-12:30 4800.95 28-JAN-24:00
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 6.39 0.00 01-JAN-00:15 3289.47 21-JUL-14:15
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Plant 2908.99 643.92 10-SEP-01:30 261993.10 29-JAN-08:00
WaterSystems:EnergyTransfer 1146.98 643.92 10-SEP-01:30 71336.31 12-DEC-07:45
sub cat:WaterSystems:EnergyTransfer 1146.98 643.92 10-SEP-01:30 71336.31 12-DEC-07:45
EnergyTransfer:HVAC 2810.87 0.00 17-APR-19:15 461294.56 28-JAN-24:00
CoolingCoils:EnergyTransfer 368.59 0.00 01-JAN-00:15 200510.05 30-JUN-12:30
HeatingCoils:EnergyTransfer 2442.28 0.00 17-APR-13:45 461294.56 28-JAN-24:00
PlantLoopHeatingDemand:HVAC 1801.45 0.00 17-APR-13:45 200881.98 12-JAN-04:00
HeatingCoils:PlantLoopHeatingDemand 1801.45 0.00 17-APR-13:45 200881.98 12-JAN-04:00
Boilers:EnergyTransfer 1762.01 0.00 20-MAR-13:00 199098.63 29-JAN-00:45



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 21.588 -3.913 0.000 0.000 3.928 1.087 12.213 14.170 0.000 0.024 0.000 0.000 -20.425 0.000 -9.018 -19.653
G NW APARTMENT 25.070 -2.277 0.000 0.000 3.965 1.087 12.213 5.809 0.000 0.025 0.000 0.000 -21.771 0.000 -8.572 -15.549
OFFICE 16.800 -12.012 0.000 0.000 0.544 29.882 9.495 15.757 0.000 0.006 0.000 0.000 -20.192 0.000 -6.401 -33.879
G NE APARTMENT 24.536 -2.581 0.000 0.000 3.963 1.087 12.213 7.281 0.000 0.025 0.000 0.000 -21.280 0.000 -8.690 -16.554
G N1 APARTMENT 16.170 -2.410 0.000 0.000 3.972 1.087 12.213 2.270 0.000 0.022 0.000 0.000 -13.500 0.000 -5.924 -13.900
G N2 APARTMENT 16.137 -2.431 0.000 0.000 3.971 1.087 12.213 2.266 0.000 0.022 0.000 0.000 -13.501 0.000 -5.934 -13.829
G S1 APARTMENT 12.687 -4.345 0.000 0.000 3.924 1.087 12.213 10.992 0.000 0.022 0.000 0.000 -12.401 0.000 -6.395 -17.783
G S2 APARTMENT 12.400 -4.519 0.000 0.000 3.919 1.087 12.213 10.976 0.000 0.022 0.000 0.000 -12.416 0.000 -6.436 -17.245
F2 SW APARTMENT 17.584 -7.527 0.000 0.000 3.873 1.087 12.213 13.677 0.000 0.030 0.000 0.000 -21.233 0.000 -12.447 -7.257
F2 NW APARTMENT 21.545 -3.910 0.000 0.000 3.927 1.087 12.213 5.438 0.000 0.030 0.000 0.000 -22.509 0.000 -11.964 -5.855
F2 SE APARTMENT 16.231 -9.785 0.000 0.000 3.863 1.087 12.213 15.235 0.000 0.030 0.000 0.000 -20.939 0.000 -12.552 -5.381
F2 NE APARTMENT 20.913 -4.860 0.000 0.000 3.928 1.087 12.213 6.907 0.000 0.030 0.000 0.000 -22.002 0.000 -12.046 -6.170
F2 N1 APARTMENT 10.733 -4.155 0.000 0.000 3.937 1.087 12.213 2.067 0.000 0.026 0.000 0.000 -14.010 0.000 -8.139 -3.758
F2 N2 APARTMENT 10.704 -4.203 0.000 0.000 3.936 1.087 12.213 2.063 0.000 0.026 0.000 0.000 -14.012 0.000 -8.150 -3.663
F2 S1 APARTMENT 7.802 -8.007 0.000 0.000 3.862 1.087 12.213 10.681 0.000 0.026 0.000 0.000 -12.899 0.000 -8.727 -6.038
F2 S2 APARTMENT 7.730 -8.180 0.000 0.000 3.860 1.087 12.213 10.674 0.000 0.026 0.000 0.000 -12.906 0.000 -8.740 -5.763
F3 SW APARTMENT 16.881 -8.225 0.000 0.000 3.867 1.087 12.213 13.505 0.000 0.037 0.000 0.000 -21.482 0.000 -14.343 -3.540
F3 NW APARTMENT 20.864 -4.302 0.000 0.000 3.919 1.087 12.213 5.317 0.000 0.038 0.000 0.000 -22.767 0.000 -13.857 -2.511
F3 SE APARTMENT 16.377 -9.675 0.000 0.000 3.865 1.087 12.213 15.093 0.000 0.037 0.000 0.000 -21.108 0.000 -14.392 -3.496
F3 NE APARTMENT 20.250 -5.309 0.000 0.000 3.921 1.087 12.213 6.786 0.000 0.038 0.000 0.000 -22.253 0.000 -13.928 -2.804
F3 N1 APARTMENT 9.612 -4.613 0.000 0.000 3.925 1.087 12.213 2.003 0.000 0.032 0.000 0.000 -14.186 0.000 -9.380 -0.691
F3 N2 APARTMENT 9.582 -4.660 0.000 0.000 3.925 1.087 12.213 1.999 0.000 0.032 0.000 0.000 -14.188 0.000 -9.391 -0.598
F3 S1 APARTMENT 6.806 -9.147 0.000 0.000 3.851 1.087 12.213 10.563 0.000 0.033 0.000 0.000 -13.065 0.000 -9.964 -2.377
F3 S2 APARTMENT 6.781 -9.250 0.000 0.000 3.850 1.087 12.213 10.559 0.000 0.033 0.000 0.000 -13.068 0.000 -9.971 -2.235
F4 SW APARTMENT 17.340 -8.278 0.000 0.000 3.868 1.087 12.213 13.407 0.000 0.040 0.000 0.000 -21.607 0.000 -15.509 -2.560
F4 NW APARTMENT 21.405 -4.343 0.000 0.000 3.918 1.087 12.213 5.255 0.000 0.040 0.000 0.000 -22.907 0.000 -15.038 -1.629
F4 SE APARTMENT 16.950 -9.596 0.000 0.000 3.867 1.087 12.213 14.996 0.000 0.040 0.000 0.000 -21.216 0.000 -15.545 -2.796
F4 NE APARTMENT 20.796 -5.367 0.000 0.000 3.920 1.087 12.213 6.722 0.000 0.040 0.000 0.000 -22.388 0.000 -15.101 -1.920
F4 N1 APARTMENT 9.726 -4.723 0.000 0.000 3.921 1.087 12.213 1.971 0.000 0.033 0.129 0.000 -14.281 0.000 -10.075 -0.000
F4 N2 APARTMENT 9.701 -4.776 0.000 0.000 3.921 1.087 12.213 1.967 0.000 0.033 0.223 0.000 -14.284 0.000 -10.085 -0.000
F4 S1 APARTMENT 6.873 -9.386 0.000 0.000 3.850 1.087 12.213 10.495 0.000 0.035 0.000 0.000 -13.146 0.000 -10.629 -1.392
F4 S2 APARTMENT 6.857 -9.468 0.000 0.000 3.849 1.087 12.213 10.492 0.000 0.035 0.000 0.000 -13.148 0.000 -10.634 -1.284
M SW APARTMENT 17.710 -8.187 0.000 0.000 3.870 1.087 12.213 13.331 0.000 0.041 0.000 0.000 -21.710 0.000 -16.673 -1.682
M NW APARTMENT 21.777 -4.320 0.000 0.000 3.919 1.087 12.213 5.213 0.000 0.042 0.000 0.000 -23.019 0.000 -16.177 -0.733
M SE APARTMENT 17.329 -9.474 0.000 0.000 3.869 1.087 12.213 14.916 0.000 0.041 0.000 0.000 -21.311 0.000 -16.710 -1.960
M NE APARTMENT 21.168 -5.341 0.000 0.000 3.921 1.087 12.213 6.676 0.000 0.041 0.000 0.000 -22.497 0.000 -16.241 -1.026
M N1 APARTMENT 9.783 -4.771 0.000 0.000 3.921 1.087 12.213 1.950 0.000 0.034 0.944 0.000 -14.356 0.000 -10.804 -0.000
M N2 APARTMENT 9.754 -4.820 0.000 0.000 3.920 1.087 12.213 1.947 0.000 0.034 1.038 0.000 -14.359 0.000 -10.814 -0.001
M S1 APARTMENT 6.941 -9.422 0.000 0.000 3.850 1.087 12.213 10.442 0.000 0.037 0.000 0.000 -13.210 0.000 -11.376 -0.562
M S2 APARTMENT 6.931 -9.502 0.000 0.000 3.850 1.087 12.213 10.439 0.000 0.037 0.001 0.000 -13.211 0.000 -11.381 -0.461
F6 SW APARTMENT 18.840 -7.543 0.000 0.000 3.876 1.087 12.213 13.295 0.000 0.043 0.000 0.000 -21.741 0.000 -17.637 -2.433
F6 NW APARTMENT 23.049 -3.933 0.000 0.000 3.927 1.087 12.213 5.209 0.000 0.043 0.000 0.000 -23.057 0.000 -17.088 -1.450
F6 SE APARTMENT 18.449 -8.788 0.000 0.000 3.875 1.087 12.213 14.876 0.000 0.043 0.000 0.000 -21.341 0.000 -17.681 -2.732
F6 NE APARTMENT 22.420 -4.912 0.000 0.000 3.929 1.087 12.213 6.667 0.000 0.043 0.000 0.000 -22.532 0.000 -17.161 -1.753
F6 N1 APARTMENT 10.632 -4.416 0.000 0.000 3.929 1.087 12.213 1.952 0.000 0.035 0.305 0.000 -14.378 0.000 -11.359 -0.000
F6 N2 APARTMENT 10.603 -4.464 0.000 0.000 3.929 1.087 12.213 1.949 0.000 0.035 0.399 0.000 -14.380 0.000 -11.369 -0.000
F6 S1 APARTMENT 7.608 -8.741 0.000 0.000 3.857 1.087 12.213 10.415 0.000 0.038 0.000 0.000 -13.227 0.000 -11.983 -1.266
F6 S2 APARTMENT 7.598 -8.820 0.000 0.000 3.856 1.087 12.213 10.412 0.000 0.038 0.000 0.000 -13.229 0.000 -11.989 -1.165
F7 SW APARTMENT 19.675 -7.112 0.000 0.000 3.881 1.087 12.213 13.259 0.000 0.044 0.000 0.000 -21.779 0.000 -18.487 -2.781
F7 NW APARTMENT 23.958 -3.684 0.000 0.000 3.934 1.087 12.213 5.202 0.000 0.044 0.000 0.000 -23.100 0.000 -17.897 -1.756
F7 SE APARTMENT 19.271 -8.328 0.000 0.000 3.880 1.087 12.213 14.837 0.000 0.044 0.000 0.000 -21.378 0.000 -18.537 -3.088
F7 NE APARTMENT 23.319 -4.639 0.000 0.000 3.935 1.087 12.213 6.656 0.000 0.044 0.000 0.000 -22.573 0.000 -17.976 -2.064
F7 N1 APARTMENT 11.210 -4.186 0.000 0.000 3.936 1.087 12.213 1.952 0.000 0.036 0.009 0.000 -14.403 0.000 -11.853 -0.000
F7 N2 APARTMENT 11.177 -4.232 0.000 0.000 3.935 1.087 12.213 1.948 0.000 0.035 0.105 0.000 -14.406 0.000 -11.864 -0.000
F7 S1 APARTMENT 8.088 -8.290 0.000 0.000 3.861 1.087 12.213 10.388 0.000 0.039 0.000 0.000 -13.249 0.000 -12.519 -1.619
F7 S2 APARTMENT 8.075 -8.365 0.000 0.000 3.861 1.087 12.213 10.385 0.000 0.039 0.000 0.000 -13.250 0.000 -12.525 -1.519
F8 SW APARTMENT 20.549 -6.744 0.000 0.000 3.886 1.087 12.213 13.228 0.000 0.045 0.000 0.000 -21.810 0.000 -19.264 -3.189
F8 NW APARTMENT 24.902 -3.503 0.000 0.000 3.939 1.087 12.213 5.194 0.000 0.045 0.000 0.000 -23.138 0.000 -18.638 -2.101
F8 SE APARTMENT 20.131 -7.936 0.000 0.000 3.885 1.087 12.213 14.802 0.000 0.045 0.000 0.000 -21.408 0.000 -19.320 -3.498
F8 NE APARTMENT 24.250 -4.429 0.000 0.000 3.940 1.087 12.213 6.645 0.000 0.044 0.000 0.000 -22.609 0.000 -18.723 -2.418
F8 N1 APARTMENT 11.853 -4.002 0.000 0.000 3.941 1.087 12.213 1.951 0.000 0.036 0.000 0.000 -14.425 0.000 -12.312 -0.342
F8 N2 APARTMENT 11.817 -4.045 0.000 0.000 3.941 1.087 12.213 1.947 0.000 0.036 0.000 0.000 -14.427 0.000 -12.324 -0.245
F8 S1 APARTMENT 8.642 -7.894 0.000 0.000 3.866 1.087 12.213 10.366 0.000 0.039 0.000 0.000 -13.265 0.000 -13.013 -2.040
F8 S2 APARTMENT 8.629 -7.971 0.000 0.000 3.866 1.087 12.213 10.363 0.000 0.039 0.000 0.000 -13.267 0.000 -13.020 -1.939
F9 SW APARTMENT 22.825 -6.329 0.000 0.000 3.892 1.087 12.213 13.217 0.000 0.046 0.000 0.000 -21.789 0.000 -19.966 -5.196
F9 NW APARTMENT 27.337 -3.355 0.000 0.000 3.943 1.087 12.213 5.193 0.000 0.046 0.000 0.000 -23.129 0.000 -19.321 -4.014
F9 SE APARTMENT 22.365 -7.467 0.000 0.000 3.891 1.087 12.213 14.790 0.000 0.046 0.000 0.000 -21.389 0.000 -20.032 -5.503
F9 NE APARTMENT 26.641 -4.244 0.000 0.000 3.945 1.087 12.213 6.643 0.000 0.045 0.000 0.000 -22.598 0.000 -19.410 -4.321
F9 N1 APARTMENT 13.850 -3.794 0.000 0.000 3.946 1.087 12.213 1.953 0.000 0.037 0.000 0.000 -14.414 0.000 -12.739 -2.139
F9 N2 APARTMENT 13.815 -3.837 0.000 0.000 3.946 1.087 12.213 1.949 0.000 0.037 0.000 0.000 -14.415 0.000 -12.751 -2.043
F9 S1 APARTMENT 10.369 -7.327 0.000 0.000 3.873 1.087 12.213 10.359 0.000 0.041 0.000 0.000 -13.247 0.000 -13.458 -3.908
F9 S2 APARTMENT 10.350 -7.398 0.000 0.000 3.872 1.087 12.213 10.355 0.000 0.041 0.000 0.000 -13.249 0.000 -13.467 -3.804
T SW APARTMENT 32.463 -6.030 0.000 0.000 3.921 1.087 12.213 13.098 0.000 0.047 0.000 0.000 -21.222 0.000 -20.543 -15.032
T NW APARTMENT 36.593 -3.014 0.000 0.000 3.957 1.087 12.213 5.115 0.000 0.047 0.000 0.000 -22.637 0.000 -19.974 -13.387
T SE APARTMENT 31.916 -6.939 0.000 0.000 3.920 1.087 12.213 14.705 0.000 0.047 0.000 0.000 -20.858 0.000 -20.572 -15.519
T NE APARTMENT 35.845 -3.827 0.000 0.000 3.963 1.087 12.213 6.587 0.000 0.047 0.000 0.000 -22.119 0.000 -20.001 -13.794
T N1 APARTMENT 22.841 -3.258 0.000 0.000 3.962 1.087 12.213 1.942 0.000 0.033 0.000 0.000 -14.083 0.000 -13.119 -11.617
T N2 APARTMENT 22.800 -3.307 0.000 0.000 3.962 1.087 12.213 1.937 0.000 0.035 0.000 0.000 -14.083 0.000 -13.129 -11.514
T S1 APARTMENT 19.211 -6.323 0.000 0.000 3.903 1.087 12.213 10.298 0.000 0.041 0.000 0.000 -12.930 0.000 -13.814 -13.685
T S2 APARTMENT 19.188 -6.391 0.000 0.000 3.902 1.087 12.213 10.292 0.000 0.041 0.000 0.000 -12.930 0.000 -13.821 -13.581
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 3.364 0.000 0.030 106.468 0.000 -4.356 0.000 -121.946 -0.002
F2 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.313 0.000 0.000 0.000 0.000 -2.712 0.000 -1.617 -13.425
F3 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.277 0.000 0.000 0.000 0.000 -2.816 0.000 -1.968 -12.933
F4 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.260 0.000 0.000 0.000 0.000 -2.852 0.000 -2.217 -12.631
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 32.880 0.000 1.241 0.000 0.000 0.000 0.000 -2.896 0.000 -2.474 -28.751
F6 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.248 0.000 0.000 0.000 0.000 -2.871 0.000 -2.569 -12.248
F7 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.249 0.000 0.000 0.000 0.000 -2.865 0.000 -2.698 -12.126
F8 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.248 0.000 0.000 0.000 0.000 -2.865 0.000 -2.820 -12.003
F9 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.248 0.000 0.000 0.000 0.000 -2.852 0.000 -2.923 -11.913
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 8.151 1.223 0.000 0.000 0.000 0.000 -2.777 0.000 -3.056 -19.982
Total Facility 1329.982 -481.888 0.000 0.000 309.191 296.560 982.450 669.314 0.000 2.954 109.623 0.000 -1452.088 0.000 -1223.094 -543.004


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 11-AUG-16:15 0.00 -2331.21 0.00 0.00 84.76 64.86 588.62 3116.44 0.00 147.17 0.00 0.00 0.00 0.00 0.00 -1670.63
G NW APARTMENT 11-JUL-17:45 0.00 -1905.86 0.00 0.00 141.81 87.56 588.62 2426.81 0.00 232.38 0.00 0.00 0.00 0.00 0.00 -1571.31
OFFICE 10-AUG-13:45 0.00 -3671.75 0.00 0.00 65.20 2345.88 588.62 3633.69 0.00 0.00 0.00 0.00 0.00 0.00 -35.65 -2925.98
G NE APARTMENT 11-JUL-05:30 0.00 -1389.19 0.00 0.00 162.99 45.40 317.85 3232.34 0.00 0.00 0.00 0.00 0.00 0.00 -90.09 -2279.31
G N1 APARTMENT 11-JUL-17:30 0.00 -1018.39 0.00 0.00 141.81 87.56 588.62 359.59 0.00 218.74 0.00 0.00 0.00 0.00 0.00 -377.92
G N2 APARTMENT 11-JUL-17:30 0.00 -1014.33 0.00 0.00 141.81 87.56 588.62 359.62 0.00 218.74 0.00 0.00 0.00 0.00 0.00 -382.01
G S1 APARTMENT 21-JUL-14:15 0.00 -1846.50 0.00 0.00 40.75 22.70 400.26 2832.73 0.00 200.55 0.00 0.00 0.00 0.00 0.00 -1650.49
G S2 APARTMENT 21-JUL-14:15 0.00 -1909.53 0.00 0.00 40.75 22.70 400.26 2831.51 0.00 200.55 0.00 0.00 0.00 0.00 0.00 -1586.23
F2 SW APARTMENT 11-AUG-16:15 0.00 -3131.97 0.00 0.00 84.76 64.86 588.62 3071.68 0.00 190.27 0.00 0.00 0.00 0.00 0.00 -868.20
F2 NW APARTMENT 11-JUL-17:30 0.00 -2498.76 0.00 0.00 141.62 87.56 588.62 2481.91 0.00 287.06 0.00 0.00 0.00 0.00 0.00 -1088.01
F2 SE APARTMENT 21-JUL-14:15 0.00 -3318.15 0.00 0.00 40.75 22.70 400.26 3116.80 0.00 228.64 0.00 0.00 0.00 0.00 0.00 -491.00
F2 NE APARTMENT 13-JUN-06:40 0.00 -1993.46 0.00 0.00 138.55 42.16 382.60 2696.69 0.00 0.00 0.00 0.00 0.00 0.00 -20.07 -1246.47
F2 N1 APARTMENT 11-JUL-16:15 0.00 -1279.80 0.00 0.00 84.62 64.86 588.62 426.57 0.00 246.50 0.00 0.00 0.00 0.00 0.00 -131.36
F2 N2 APARTMENT 11-JUL-16:15 0.00 -1264.63 0.00 0.00 84.52 64.86 588.62 426.20 0.00 241.63 0.00 0.00 0.00 0.00 0.00 -141.20
F2 S1 APARTMENT 21-JUL-14:15 0.00 -2506.63 0.00 0.00 40.75 22.70 400.26 2812.42 0.00 219.25 0.00 0.00 0.00 0.00 0.00 -988.75
F2 S2 APARTMENT 21-JUL-14:15 0.00 -2533.44 0.00 0.00 40.75 22.70 400.26 2812.02 0.00 219.25 0.00 0.00 0.00 0.00 0.00 -961.54
F3 SW APARTMENT 11-AUG-16:15 0.00 -3200.47 0.00 0.00 84.76 64.86 588.62 3052.10 0.00 215.40 0.00 0.00 0.00 0.00 0.00 -805.27
F3 NW APARTMENT 11-JUL-17:30 0.00 -2536.33 0.00 0.00 141.28 87.56 588.62 2467.24 0.00 313.17 0.00 0.00 0.00 0.00 0.00 -1061.54
F3 SE APARTMENT 22-JUL-12:00 0.00 -3320.66 0.00 0.00 40.75 12.97 406.15 3444.87 0.00 296.98 0.00 0.00 0.00 0.00 0.00 -881.05
F3 NE APARTMENT 13-JUN-06:40 0.00 -2086.48 0.00 0.00 138.55 42.16 382.60 2692.76 0.00 0.00 0.00 0.00 0.00 0.00 -23.80 -1145.78
F3 N1 APARTMENT 29-JUN-19:15 0.00 -1362.18 0.00 0.00 141.79 103.77 523.87 495.88 0.00 86.19 10.68 0.00 0.00 0.00 0.00 0.00
F3 N2 APARTMENT 29-JUN-19:15 0.00 -1347.00 0.00 0.00 141.72 103.77 523.87 495.94 0.00 85.09 0.00 0.00 0.00 0.00 0.00 -3.39
F3 S1 APARTMENT 21-JUL-14:15 0.00 -2584.81 0.00 0.00 40.75 22.70 400.26 2801.76 0.00 231.32 0.00 0.00 0.00 0.00 0.00 -911.99
F3 S2 APARTMENT 21-JUL-14:15 0.00 -2602.41 0.00 0.00 40.75 22.70 400.26 2801.49 0.00 231.32 0.00 0.00 0.00 0.00 0.00 -894.10
F4 SW APARTMENT 11-JUL-17:30 0.00 -3222.60 0.00 0.00 141.81 87.56 588.62 2671.32 0.00 318.34 0.00 0.00 0.00 0.00 0.00 -585.04
F4 NW APARTMENT 11-JUL-17:15 0.00 -2537.87 0.00 0.00 141.61 87.56 588.62 2391.66 0.00 350.87 0.00 0.00 0.00 0.00 0.00 -1022.45
F4 SE APARTMENT 22-JUL-12:00 0.00 -3334.49 0.00 0.00 40.75 12.97 406.15 3432.50 0.00 312.47 0.00 0.00 0.00 0.00 0.00 -870.34
F4 NE APARTMENT 13-JUN-07:00 0.00 -2133.85 0.00 0.00 138.55 42.16 382.60 2635.85 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -1065.30
F4 N1 APARTMENT 29-JUN-19:30 0.00 -1373.75 0.00 0.00 141.57 103.77 523.87 548.52 0.00 81.51 0.00 0.00 0.00 0.00 0.00 -25.49
F4 N2 APARTMENT 29-JUN-19:30 0.00 -1358.25 0.00 0.00 141.45 103.77 523.87 548.50 0.00 80.09 0.00 0.00 0.00 0.00 0.00 -39.42
F4 S1 APARTMENT 21-JUL-14:15 0.00 -2606.67 0.00 0.00 40.75 22.70 400.26 2793.93 0.00 240.45 0.00 0.00 0.00 0.00 0.00 -891.42
F4 S2 APARTMENT 21-JUL-14:15 0.00 -2623.11 0.00 0.00 40.75 22.70 400.26 2793.67 0.00 240.45 0.00 0.00 0.00 0.00 0.00 -874.72
M SW APARTMENT 11-JUL-17:30 0.00 -3261.82 0.00 0.00 141.81 87.56 588.62 2662.43 0.00 336.80 0.00 0.00 0.00 0.00 0.00 -555.39
M NW APARTMENT 11-JUL-17:15 0.00 -2558.38 0.00 0.00 141.46 87.56 588.62 2383.76 0.00 366.46 0.00 0.00 0.00 0.00 0.00 -1009.48
M SE APARTMENT 22-JUL-12:00 0.00 -3367.61 0.00 0.00 40.75 12.97 406.15 3421.70 0.00 324.98 0.00 0.00 0.00 0.00 0.00 -838.94
M NE APARTMENT 13-JUN-07:00 0.00 -2157.79 0.00 0.00 138.55 42.16 382.60 2634.65 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -1040.17
M N1 APARTMENT 29-JUN-19:30 0.00 -1402.16 0.00 0.00 141.48 103.77 523.87 545.60 0.00 83.34 4.11 0.00 0.00 0.00 0.00 0.00
M N2 APARTMENT 29-JUN-19:30 0.00 -1386.22 0.00 0.00 141.34 103.77 523.87 545.56 0.00 81.81 0.00 0.00 0.00 0.00 0.00 -10.14
M S1 APARTMENT 21-JUL-14:15 0.00 -2638.88 0.00 0.00 40.75 22.70 400.26 2787.10 0.00 247.76 0.00 0.00 0.00 0.00 0.00 -859.69
M S2 APARTMENT 21-JUL-14:15 0.00 -2655.12 0.00 0.00 40.75 22.70 400.26 2786.84 0.00 247.76 0.00 0.00 0.00 0.00 0.00 -843.19
F6 SW APARTMENT 11-JUL-17:30 0.00 -3236.58 0.00 0.00 141.81 87.56 588.62 2656.62 0.00 351.84 0.00 0.00 0.00 0.00 0.00 -589.86
F6 NW APARTMENT 11-JUL-17:15 0.00 -2512.45 0.00 0.00 141.25 87.56 588.62 2378.56 0.00 376.92 0.00 0.00 0.00 0.00 0.00 -1060.46
F6 SE APARTMENT 22-JUL-12:00 0.00 -3339.98 0.00 0.00 40.75 12.97 406.15 3413.82 0.00 335.42 0.00 0.00 0.00 0.00 0.00 -869.13
F6 NE APARTMENT 13-JUN-07:00 0.00 -2119.03 0.00 0.00 138.55 42.16 382.60 2635.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -1079.47
F6 N1 APARTMENT 29-JUN-19:30 0.00 -1361.24 0.00 0.00 141.33 103.77 523.87 544.13 0.00 83.45 0.00 0.00 0.00 0.00 0.00 -35.31
F6 N2 APARTMENT 29-JUN-19:30 0.00 -1344.46 0.00 0.00 141.20 103.77 523.87 544.08 0.00 81.79 0.00 0.00 0.00 0.00 0.00 -50.25
F6 S1 APARTMENT 21-JUL-14:15 0.00 -2606.39 0.00 0.00 40.75 22.70 400.26 2782.10 0.00 253.81 0.00 0.00 0.00 0.00 0.00 -893.23
F6 S2 APARTMENT 21-JUL-14:15 0.00 -2622.75 0.00 0.00 40.75 22.70 400.26 2781.84 0.00 253.81 0.00 0.00 0.00 0.00 0.00 -876.61
F7 SW APARTMENT 11-JUL-17:30 0.00 -3230.42 0.00 0.00 141.81 87.56 588.62 2651.14 0.00 364.35 0.00 0.00 0.00 0.00 0.00 -603.05
F7 NW APARTMENT 11-JUL-17:15 0.00 -2491.70 0.00 0.00 141.08 87.56 588.62 2373.62 0.00 385.72 0.00 0.00 0.00 0.00 0.00 -1084.90
F7 SE APARTMENT 22-JUL-12:00 0.00 -3333.58 0.00 0.00 40.75 12.97 406.15 3406.35 0.00 344.31 0.00 0.00 0.00 0.00 0.00 -876.95
F7 NE APARTMENT 13-JUN-07:00 0.00 -2100.81 0.00 0.00 138.55 42.16 382.60 2635.16 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -1097.65
F7 N1 APARTMENT 29-JUN-19:45 0.00 -1344.41 0.00 0.00 141.27 103.77 523.87 533.00 0.00 75.69 0.00 0.00 0.00 0.00 0.00 -33.18
F7 N2 APARTMENT 29-JUN-19:45 0.00 -1329.04 0.00 0.00 141.14 103.77 523.87 532.97 0.00 73.99 0.00 0.00 0.00 0.00 0.00 -46.71
F7 S1 APARTMENT 21-JUL-14:15 0.00 -2594.40 0.00 0.00 40.75 22.70 400.26 2777.34 0.00 258.89 0.00 0.00 0.00 0.00 0.00 -905.53
F7 S2 APARTMENT 21-JUL-14:15 0.00 -2610.90 0.00 0.00 40.75 22.70 400.26 2777.07 0.00 258.89 0.00 0.00 0.00 0.00 0.00 -888.77
F8 SW APARTMENT 11-JUL-17:30 0.00 -3232.84 0.00 0.00 141.81 87.56 588.62 2646.05 0.00 374.88 0.00 0.00 0.00 0.00 0.00 -606.08
F8 NW APARTMENT 11-JUL-17:15 0.00 -2484.60 0.00 0.00 140.97 87.56 588.62 2369.03 0.00 393.49 0.00 0.00 0.00 0.00 0.00 -1095.06
F8 SE APARTMENT 22-JUL-12:00 0.00 -3335.09 0.00 0.00 40.75 12.97 406.15 3399.43 0.00 351.97 0.00 0.00 0.00 0.00 0.00 -876.19
F8 NE APARTMENT 13-JUN-07:00 0.00 -2092.11 0.00 0.00 138.55 42.16 382.60 2634.84 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -1106.04
F8 N1 APARTMENT 29-JUN-19:45 0.00 -1344.92 0.00 0.00 141.25 103.77 523.87 531.41 0.00 76.08 0.00 0.00 0.00 0.00 0.00 -31.46
F8 N2 APARTMENT 29-JUN-19:45 0.00 -1329.60 0.00 0.00 141.12 103.77 523.87 531.37 0.00 74.35 0.00 0.00 0.00 0.00 0.00 -44.88
F8 S1 APARTMENT 21-JUL-14:15 0.00 -2591.29 0.00 0.00 40.75 22.70 400.26 2772.88 0.00 263.21 0.00 0.00 0.00 0.00 0.00 -908.51
F8 S2 APARTMENT 21-JUL-14:15 0.00 -2608.06 0.00 0.00 40.75 22.70 400.26 2772.61 0.00 263.21 0.00 0.00 0.00 0.00 0.00 -891.46
F9 SW APARTMENT 11-JUL-17:30 0.00 -3301.00 0.00 0.00 141.80 87.56 588.62 2639.49 0.00 383.83 0.00 0.00 0.00 0.00 0.00 -540.29
F9 NW APARTMENT 11-JUL-17:15 0.00 -2554.14 0.00 0.00 141.08 87.56 588.62 2363.37 0.00 406.44 0.00 0.00 0.00 0.00 0.00 -1032.92
F9 SE APARTMENT 22-JUL-12:00 0.00 -3375.69 0.00 0.00 40.75 12.97 406.15 3391.99 0.00 358.64 0.00 0.00 0.00 0.00 0.00 -834.80
F9 NE APARTMENT 13-JUN-07:00 0.00 -2087.14 0.00 0.00 138.55 42.16 382.60 2634.46 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -1110.63
F9 N1 APARTMENT 29-JUN-19:45 0.00 -1408.90 0.00 0.00 141.31 103.77 523.87 528.52 0.00 76.90 34.52 0.00 0.00 0.00 0.00 0.00
F9 N2 APARTMENT 29-JUN-19:45 0.00 -1392.80 0.00 0.00 141.20 103.77 523.87 528.54 0.00 75.32 20.09 0.00 0.00 0.00 0.00 0.00
F9 S1 APARTMENT 21-JUL-14:15 0.00 -2623.16 0.00 0.00 40.75 22.70 400.26 2768.19 0.00 266.89 0.00 0.00 0.00 0.00 0.00 -875.62
F9 S2 APARTMENT 21-JUL-14:15 0.00 -2642.27 0.00 0.00 40.75 22.70 400.26 2767.87 0.00 266.89 0.00 0.00 0.00 0.00 0.00 -856.20
T SW APARTMENT 20-JUN-16:15 0.00 -3781.34 0.00 0.00 84.76 64.86 588.62 3156.41 0.00 200.79 0.00 0.00 0.00 0.00 0.00 -314.09
T NW APARTMENT 11-JUL-17:15 0.00 -3021.46 0.00 0.00 141.47 87.56 588.62 2332.31 0.00 428.62 0.00 0.00 0.00 0.00 0.00 -557.12
T SE APARTMENT 22-JUL-12:00 0.00 -3919.37 0.00 0.00 40.75 12.97 406.15 3349.83 0.00 364.47 0.00 0.00 0.00 0.00 0.00 -254.81
T NE APARTMENT 22-JUL-12:00 0.00 -2385.77 0.00 0.00 40.49 12.97 406.15 1095.26 0.00 339.69 491.21 0.00 0.00 0.00 0.00 0.00
T N1 APARTMENT 29-JUN-19:30 0.00 -1565.56 0.00 0.00 140.14 103.77 523.87 528.14 0.00 70.23 199.40 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 29-JUN-19:30 0.00 -1589.04 0.00 0.00 141.03 103.77 523.87 530.13 0.00 82.31 207.93 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 21-JUL-14:15 0.00 -3274.74 0.00 0.00 40.75 22.70 400.26 2742.51 0.00 270.05 0.00 0.00 0.00 0.00 0.00 -201.54
T S2 APARTMENT 21-JUL-14:15 0.00 -3289.01 0.00 0.00 40.75 22.70 400.26 2742.23 0.00 270.05 0.00 0.00 0.00 0.00 0.00 -186.98
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 11-JUL-16:15 0.00 -175271.48 0.00 0.00 6680.88 11327.17 47312.53 114084.90 0.00 24519.98 0.00 0.00 0.00 0.00 -128.08 -28525.90


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 28-JAN-24:00 3811.74 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1741.17 0.00 -2066.53 -551.31
G NW APARTMENT 28-JAN-24:00 3878.27 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1752.49 0.00 -2066.55 -606.51
OFFICE 28-JAN-24:00 3833.04 0.00 0.00 0.00 0.00 469.18 194.24 0.00 0.00 0.00 0.00 0.00 -1752.25 0.00 -2066.51 -677.70
G NE APARTMENT 28-JAN-24:00 3886.15 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1762.57 0.00 -2066.55 -604.30
G N1 APARTMENT 29-JAN-00:15 2435.50 0.00 0.00 0.00 189.66 6.49 264.88 0.00 0.00 0.00 0.00 0.00 -1071.44 0.00 -1214.70 -610.38
G N2 APARTMENT 29-JAN-00:15 2435.62 0.00 0.00 0.00 189.66 6.49 264.88 0.00 0.00 0.00 0.00 0.00 -1071.43 0.00 -1214.70 -610.50
G S1 APARTMENT 29-JAN-00:15 2344.59 0.00 0.00 0.00 189.67 6.49 264.88 0.00 0.00 0.00 0.00 0.00 -1061.15 0.00 -1214.68 -529.78
G S2 APARTMENT 29-JAN-00:15 2339.02 0.00 0.00 0.00 189.67 6.49 264.88 0.00 0.00 0.00 0.00 0.00 -1061.26 0.00 -1214.68 -524.11
F2 SW APARTMENT 28-JAN-24:00 4439.92 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1801.25 0.00 -2971.04 -214.92
F2 NW APARTMENT 28-JAN-24:00 4566.40 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1822.71 0.00 -2971.06 -319.91
F2 SE APARTMENT 28-JAN-24:00 4430.48 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1819.68 0.00 -2971.04 -187.05
F2 NE APARTMENT 28-JAN-24:00 4580.30 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1840.29 0.00 -2971.08 -316.20
F2 N1 APARTMENT 29-JAN-00:15 2661.73 0.00 0.00 0.00 189.66 6.49 264.88 0.00 0.00 0.00 0.00 0.00 -1121.21 0.00 -1746.38 -255.17
F2 N2 APARTMENT 29-JAN-00:15 2661.91 0.00 0.00 0.00 189.66 6.49 264.88 0.00 0.00 0.00 0.00 0.00 -1121.20 0.00 -1746.38 -255.35
F2 S1 APARTMENT 29-JAN-00:15 2534.88 0.00 0.00 0.00 189.67 6.49 264.88 0.00 0.00 0.00 0.00 0.00 -1096.80 0.00 -1746.33 -152.78
F2 S2 APARTMENT 29-JAN-00:15 2533.17 0.00 0.00 0.00 189.67 6.49 264.88 0.00 0.00 0.00 0.00 0.00 -1096.84 0.00 -1746.33 -151.03
F3 SW APARTMENT 28-JAN-24:00 4852.72 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1825.24 0.00 -3518.35 -56.41
F3 NW APARTMENT 28-JAN-24:00 4984.90 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1851.52 0.00 -3518.38 -162.28
F3 SE APARTMENT 28-JAN-24:00 4864.23 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1846.39 0.00 -3518.35 -46.77
F3 NE APARTMENT 28-JAN-24:00 5001.22 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1872.39 0.00 -3518.39 -157.71
F3 N1 APARTMENT 28-JAN-24:00 2855.67 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1142.92 0.00 -2122.23 -137.79
F3 N2 APARTMENT 28-JAN-24:00 2855.87 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1142.92 0.00 -2122.23 -137.99
F3 S1 APARTMENT 28-JAN-24:00 2719.16 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1112.99 0.00 -2122.18 -31.27
F3 S2 APARTMENT 28-JAN-24:00 2718.83 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1113.00 0.00 -2122.18 -30.93
F4 SW APARTMENT 28-JAN-24:00 5252.76 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1839.07 0.00 -3933.51 -27.47
F4 NW APARTMENT 28-JAN-24:00 5388.20 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1868.31 0.00 -3933.53 -133.63
F4 SE APARTMENT 28-JAN-24:00 5269.39 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1862.11 0.00 -3933.51 -21.06
F4 NE APARTMENT 28-JAN-24:00 5406.11 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1891.18 0.00 -3933.55 -128.66
F4 N1 APARTMENT 28-JAN-24:00 3088.68 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1154.63 0.00 -2372.64 -108.68
F4 N2 APARTMENT 28-JAN-24:00 3088.90 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1154.62 0.00 -2372.64 -108.91
F4 S1 APARTMENT 28-JAN-24:00 2948.42 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1121.62 0.00 -2372.59 -1.49
F4 S2 APARTMENT 28-JAN-24:00 2948.49 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1121.62 0.00 -2372.59 -1.56
M SW APARTMENT 28-JAN-24:00 5578.31 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.02 0.00 -1849.81 0.00 -4275.80 0.00
M NW APARTMENT 28-JAN-24:00 5714.43 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1881.14 0.00 -4275.82 -104.75
M SE APARTMENT 28-JAN-24:00 5596.61 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 6.16 0.00 -1874.26 0.00 -4275.80 0.00
M NE APARTMENT 28-JAN-24:00 5733.46 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1905.41 0.00 -4275.85 -99.48
M N1 APARTMENT 28-JAN-24:00 3276.35 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1163.48 0.00 -2579.10 -81.04
M N2 APARTMENT 28-JAN-24:00 3276.59 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1163.48 0.00 -2579.11 -81.28
M S1 APARTMENT 28-JAN-24:00 3135.45 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 24.62 0.00 -1128.30 0.00 -2579.05 0.00
M S2 APARTMENT 28-JAN-24:00 3135.61 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 24.45 0.00 -1128.29 0.00 -2579.05 0.00
F6 SW APARTMENT 28-JAN-24:00 5912.67 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1856.79 0.00 -4570.84 -32.32
F6 NW APARTMENT 28-JAN-24:00 6050.60 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1889.74 0.00 -4570.87 -137.27
F6 SE APARTMENT 28-JAN-24:00 5931.96 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1882.28 0.00 -4570.84 -26.12
F6 NE APARTMENT 28-JAN-24:00 6070.52 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1915.05 0.00 -4570.89 -131.85
F6 N1 APARTMENT 28-JAN-24:00 3491.14 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1169.36 0.00 -2757.07 -111.98
F6 N2 APARTMENT 28-JAN-24:00 3491.39 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1169.35 0.00 -2757.07 -112.24
F6 S1 APARTMENT 28-JAN-24:00 3348.15 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1132.53 0.00 -2757.01 -5.89
F6 S2 APARTMENT 28-JAN-24:00 3348.34 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1132.52 0.00 -2757.01 -6.09
F7 SW APARTMENT 28-JAN-24:00 6194.74 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1863.12 0.00 -4832.32 -46.58
F7 NW APARTMENT 28-JAN-24:00 6333.01 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1897.34 0.00 -4832.35 -150.59
F7 SE APARTMENT 28-JAN-24:00 6214.77 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1889.44 0.00 -4832.33 -40.28
F7 NE APARTMENT 28-JAN-24:00 6171.82 0.00 0.00 0.00 189.94 16.21 341.40 0.00 0.00 0.00 20.76 0.00 -1922.82 0.00 -4817.31 0.00
F7 N1 APARTMENT 28-JAN-24:00 3667.47 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1174.52 0.00 -2914.80 -125.43
F7 N2 APARTMENT 28-JAN-24:00 3667.76 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1174.51 0.00 -2914.80 -125.73
F7 S1 APARTMENT 28-JAN-24:00 3524.23 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1136.36 0.00 -2914.73 -20.41
F7 S2 APARTMENT 28-JAN-24:00 3524.44 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1136.36 0.00 -2914.73 -20.63
F8 SW APARTMENT 28-JAN-24:00 6457.49 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1868.39 0.00 -5068.54 -67.84
F8 NW APARTMENT 28-JAN-24:00 6595.95 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1903.65 0.00 -5068.57 -171.00
F8 SE APARTMENT 28-JAN-24:00 6478.15 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1895.38 0.00 -5068.54 -61.50
F8 NE APARTMENT 28-JAN-24:00 6228.34 0.00 0.00 0.00 191.57 16.21 341.40 0.00 0.00 0.00 174.53 0.00 -1925.38 0.00 -5026.67 0.00
F8 N1 APARTMENT 28-JAN-24:00 3834.93 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1178.75 0.00 -3057.28 -146.18
F8 N2 APARTMENT 28-JAN-24:00 3835.56 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1178.74 0.00 -3057.28 -146.81
F8 S1 APARTMENT 28-JAN-24:00 3691.72 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1139.52 0.00 -3057.21 -42.27
F8 S2 APARTMENT 28-JAN-24:00 3691.96 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1139.52 0.00 -3057.21 -42.51
F9 SW APARTMENT 28-JAN-24:00 6812.33 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1869.78 0.00 -5284.94 -204.90
F9 NW APARTMENT 28-JAN-24:00 6950.74 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1905.76 0.00 -5284.97 -307.28
F9 SE APARTMENT 28-JAN-24:00 6834.07 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1897.27 0.00 -5284.94 -199.15
F9 NE APARTMENT 28-JAN-24:00 6510.10 0.00 0.00 0.00 192.19 16.21 341.40 0.00 0.00 0.00 98.88 0.00 -1926.15 0.00 -5232.63 0.00
F9 N1 APARTMENT 28-JAN-24:00 4093.12 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1180.15 0.00 -3187.80 -272.44
F9 N2 APARTMENT 28-JAN-24:00 4093.97 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1180.14 0.00 -3187.80 -273.30
F9 S1 APARTMENT 28-JAN-24:00 3949.38 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1140.18 0.00 -3187.74 -168.74
F9 S2 APARTMENT 28-JAN-24:00 3949.67 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1140.18 0.00 -3187.74 -169.03
T SW APARTMENT 28-JAN-24:00 7709.37 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1840.38 0.00 -5484.85 -931.42
T NW APARTMENT 28-JAN-24:00 7798.95 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1876.38 0.00 -5484.88 -984.97
T SE APARTMENT 28-JAN-24:00 7732.02 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1867.64 0.00 -5484.85 -926.81
T NE APARTMENT 28-JAN-24:00 7962.33 0.00 0.00 0.00 188.13 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1907.43 0.00 -5508.89 -1091.75
T N1 APARTMENT 28-JAN-24:00 4896.81 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1160.43 0.00 -3308.52 -975.13
T N2 APARTMENT 28-JAN-24:00 4937.53 0.00 0.00 0.00 189.66 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1160.42 0.00 -3310.65 -1013.73
T S1 APARTMENT 28-JAN-24:00 4799.72 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1123.57 0.00 -3308.44 -914.99
T S2 APARTMENT 28-JAN-24:00 4800.18 0.00 0.00 0.00 189.67 16.21 341.40 0.00 0.00 0.00 0.00 0.00 -1123.56 0.00 -3308.44 -915.46
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 28-JAN-24:00 364621.46 0.00 0.00 0.00 14986.73 7484.42 27274.70 0.00 0.00 0.00 0.00 0.00 -122370.71 0.00 -276163.06 -15833.53



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Sec1.1A-General Information

Data
Weather File Fairbanks Intl Arpt AK USA TMY3 WMO#=702610
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 7836.48
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.50
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
F2 SW APARTMENT 88.25 88.25 0.00 168.00
F2 NW APARTMENT 88.25 88.25 0.00 168.00
F2 SE APARTMENT 88.25 88.25 0.00 168.00
F2 NE APARTMENT 88.25 88.25 0.00 168.00
F2 N1 APARTMENT 88.25 88.25 0.00 168.00
F2 N2 APARTMENT 88.25 88.25 0.00 168.00
F2 S1 APARTMENT 88.25 88.25 0.00 168.00
F2 S2 APARTMENT 88.25 88.25 0.00 168.00
F3 SW APARTMENT 88.25 88.25 0.00 168.00
F3 NW APARTMENT 88.25 88.25 0.00 168.00
F3 SE APARTMENT 88.25 88.25 0.00 168.00
F3 NE APARTMENT 88.25 88.25 0.00 168.00
F3 N1 APARTMENT 88.25 88.25 0.00 168.00
F3 N2 APARTMENT 88.25 88.25 0.00 168.00
F3 S1 APARTMENT 88.25 88.25 0.00 168.00
F3 S2 APARTMENT 88.25 88.25 0.00 168.00
F4 SW APARTMENT 88.25 88.25 0.00 168.00
F4 NW APARTMENT 88.25 88.25 0.00 168.00
F4 SE APARTMENT 88.25 88.25 0.00 168.00
F4 NE APARTMENT 88.25 88.25 0.00 168.00
F4 N1 APARTMENT 88.25 88.25 0.00 168.00
F4 N2 APARTMENT 88.25 88.25 0.00 168.00
F4 S1 APARTMENT 88.25 88.25 0.00 168.00
F4 S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
F6 SW APARTMENT 88.25 88.25 0.00 168.00
F6 NW APARTMENT 88.25 88.25 0.00 168.00
F6 SE APARTMENT 88.25 88.25 0.00 168.00
F6 NE APARTMENT 88.25 88.25 0.00 168.00
F6 N1 APARTMENT 88.25 88.25 0.00 168.00
F6 N2 APARTMENT 88.25 88.25 0.00 168.00
F6 S1 APARTMENT 88.25 88.25 0.00 168.00
F6 S2 APARTMENT 88.25 88.25 0.00 168.00
F7 SW APARTMENT 88.25 88.25 0.00 168.00
F7 NW APARTMENT 88.25 88.25 0.00 168.00
F7 SE APARTMENT 88.25 88.25 0.00 168.00
F7 NE APARTMENT 88.25 88.25 0.00 168.00
F7 N1 APARTMENT 88.25 88.25 0.00 168.00
F7 N2 APARTMENT 88.25 88.25 0.00 168.00
F7 S1 APARTMENT 88.25 88.25 0.00 168.00
F7 S2 APARTMENT 88.25 88.25 0.00 168.00
F8 SW APARTMENT 88.25 88.25 0.00 168.00
F8 NW APARTMENT 88.25 88.25 0.00 168.00
F8 SE APARTMENT 88.25 88.25 0.00 168.00
F8 NE APARTMENT 88.25 88.25 0.00 168.00
F8 N1 APARTMENT 88.25 88.25 0.00 168.00
F8 N2 APARTMENT 88.25 88.25 0.00 168.00
F8 S1 APARTMENT 88.25 88.25 0.00 168.00
F8 S2 APARTMENT 88.25 88.25 0.00 168.00
F9 SW APARTMENT 88.25 88.25 0.00 168.00
F9 NW APARTMENT 88.25 88.25 0.00 168.00
F9 SE APARTMENT 88.25 88.25 0.00 168.00
F9 NE APARTMENT 88.25 88.25 0.00 168.00
F9 N1 APARTMENT 88.25 88.25 0.00 168.00
F9 N2 APARTMENT 88.25 88.25 0.00 168.00
F9 S1 APARTMENT 88.25 88.25 0.00 168.00
F9 S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
G CORRIDOR 77.66 0.00 77.66 0.00
F2 CORRIDOR 77.66 0.00 77.66 0.00
F3 CORRIDOR 77.66 0.00 77.66 0.00
F4 CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
F6 CORRIDOR 77.66 0.00 77.66 0.00
F7 CORRIDOR 77.66 0.00 77.66 0.00
F8 CORRIDOR 77.66 0.00 77.66 0.00
F9 CORRIDOR 77.66 0.00 77.66 0.00
T CORRIDOR 77.66 0.00 77.66 0.00
Totals 7836.48 7059.89 776.58  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 115.25
Number of hours cooling loads not met 28.25
Number of hours not met 143.50


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 296.56 7484.42 0.00 0.00 0.00 0.00
Exterior Lighting 161.58 10364.00 0.00 0.00 0.00 0.00
Space Heating 673.86 261078.47 2349.92 254312.63 0.00 0.00
Space Cooling 123.96 0.00 0.00 0.00 0.00 0.00
Pumps 55.17 1756.43 0.00 0.00 0.00 0.00
Heat Rejection 4.75 0.00 0.00 0.00 0.00 0.00
Fans-Interior 668.13 21186.30 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 0.00 0.00 1467.86 89941.37 0.00 0.00
Receptacle Equipment 1137.32 29363.65 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 3157.51   3817.79   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 1137.32 3157.51
Natural Gas 0.00 3817.79
Additional 0.00 0.00
Total 1137.32 6975.30


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 37.84
Space Heating 85.99
Space Cooling 15.82
Fans-Interior 85.26
Service Water Heating 0.00
Receptacle Equipment 145.13
Miscellaneous 32.88
Subtotal 402.93


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 299.87
Service Water Heating 187.31
Miscellaneous -0.00
Subtotal 487.18


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 4.25
Space Heating 43.35
Space Cooling 1.78
Fans-Interior 9.58
Service Water Heating 21.04
Receptacle Equipment 16.31
Miscellaneous 3.69



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.237396
G NW APARTMENT DIRECT AIR 0.181298
OFFICE DIRECT AIR 0.372198
G NE APARTMENT DIRECT AIR 0.181218
G N1 APARTMENT DIRECT AIR 0.134206
G N2 APARTMENT DIRECT AIR 0.134204
G S1 APARTMENT DIRECT AIR 0.179553
G S2 APARTMENT DIRECT AIR 0.186289
F2 SW APARTMENT DIRECT AIR 0.317993
F2 NW APARTMENT DIRECT AIR 0.229434
F2 SE APARTMENT DIRECT AIR 0.329993
F2 NE APARTMENT DIRECT AIR 0.186648
F2 N1 APARTMENT DIRECT AIR 0.125199
F2 N2 APARTMENT DIRECT AIR 0.123705
F2 S1 APARTMENT DIRECT AIR 0.244500
F2 S2 APARTMENT DIRECT AIR 0.246991
F3 SW APARTMENT DIRECT AIR 0.320511
F3 NW APARTMENT DIRECT AIR 0.233178
F3 SE APARTMENT DIRECT AIR 0.311325
F3 NE APARTMENT DIRECT AIR 0.190812
F3 N1 APARTMENT DIRECT AIR 0.129973
F3 N2 APARTMENT DIRECT AIR 0.128502
F3 S1 APARTMENT DIRECT AIR 0.248982
F3 S2 APARTMENT DIRECT AIR 0.250175
F4 SW APARTMENT DIRECT AIR 0.320921
F4 NW APARTMENT DIRECT AIR 0.233670
F4 SE APARTMENT DIRECT AIR 0.309899
F4 NE APARTMENT DIRECT AIR 0.191177
F4 N1 APARTMENT DIRECT AIR 0.130771
F4 N2 APARTMENT DIRECT AIR 0.129300
F4 S1 APARTMENT DIRECT AIR 0.249871
F4 S2 APARTMENT DIRECT AIR 0.250884
M SW APARTMENT DIRECT AIR 0.322998
M NW APARTMENT DIRECT AIR 0.235787
M SE APARTMENT DIRECT AIR 0.311915
M NE APARTMENT DIRECT AIR 0.193157
M N1 APARTMENT DIRECT AIR 0.133050
M N2 APARTMENT DIRECT AIR 0.131582
M S1 APARTMENT DIRECT AIR 0.252258
M S2 APARTMENT DIRECT AIR 0.253243
F6 SW APARTMENT DIRECT AIR 0.319338
F6 NW APARTMENT DIRECT AIR 0.232157
F6 SE APARTMENT DIRECT AIR 0.308433
F6 NE APARTMENT DIRECT AIR 0.189541
F6 N1 APARTMENT DIRECT AIR 0.129741
F6 N2 APARTMENT DIRECT AIR 0.128279
F6 S1 APARTMENT DIRECT AIR 0.248844
F6 S2 APARTMENT DIRECT AIR 0.249826
F7 SW APARTMENT DIRECT AIR 0.317815
F7 NW APARTMENT DIRECT AIR 0.230685
F7 SE APARTMENT DIRECT AIR 0.307057
F7 NE APARTMENT DIRECT AIR 0.188094
F7 N1 APARTMENT DIRECT AIR 0.128496
F7 N2 APARTMENT DIRECT AIR 0.127040
F7 S1 APARTMENT DIRECT AIR 0.247531
F7 S2 APARTMENT DIRECT AIR 0.248511
F8 SW APARTMENT DIRECT AIR 0.317379
F8 NW APARTMENT DIRECT AIR 0.230379
F8 SE APARTMENT DIRECT AIR 0.306744
F8 NE APARTMENT DIRECT AIR 0.187753
F8 N1 APARTMENT DIRECT AIR 0.128448
F8 N2 APARTMENT DIRECT AIR 0.126999
F8 S1 APARTMENT DIRECT AIR 0.247283
F8 S2 APARTMENT DIRECT AIR 0.248264
F9 SW APARTMENT DIRECT AIR 0.323540
F9 NW APARTMENT DIRECT AIR 0.236842
F9 SE APARTMENT DIRECT AIR 0.312150
F9 NE APARTMENT DIRECT AIR 0.190196
F9 N1 APARTMENT DIRECT AIR 0.134116
F9 N2 APARTMENT DIRECT AIR 0.132607
F9 S1 APARTMENT DIRECT AIR 0.251727
F9 S2 APARTMENT DIRECT AIR 0.252830
T SW APARTMENT DIRECT AIR 0.377844
T NW APARTMENT DIRECT AIR 0.276439
T SE APARTMENT DIRECT AIR 0.359181
T NE APARTMENT DIRECT AIR 0.216994
T N1 APARTMENT DIRECT AIR 0.146326
T N2 APARTMENT DIRECT AIR 0.143566
T S1 APARTMENT DIRECT AIR 0.312997
T S2 APARTMENT DIRECT AIR 0.314095


Branch

Maximum Flow Rate [m3/s]
AIRLOOP G SW MAIN BRANCH 0.237396
AIRLOOP G NW MAIN BRANCH 0.181298
AIRLOOP OFFICE MAIN BRANCH 0.372198
AIRLOOP G NE MAIN BRANCH 0.181218
AIRLOOP G N1 MAIN BRANCH 0.134206
AIRLOOP G N2 MAIN BRANCH 0.134204
AIRLOOP G S1 MAIN BRANCH 0.179553
AIRLOOP G S2 MAIN BRANCH 0.186289
AIRLOOP F2 SW MAIN BRANCH 0.317993
AIRLOOP F2 NW MAIN BRANCH 0.229434
AIRLOOP F2 SE MAIN BRANCH 0.329993
AIRLOOP F2 NE MAIN BRANCH 0.186648
AIRLOOP F2 N1 MAIN BRANCH 0.125199
AIRLOOP F2 N2 MAIN BRANCH 0.123705
AIRLOOP F2 S1 MAIN BRANCH 0.244500
AIRLOOP F2 S2 MAIN BRANCH 0.246991
AIRLOOP F3 SW MAIN BRANCH 0.320511
AIRLOOP F3 NW MAIN BRANCH 0.233178
AIRLOOP F3 SE MAIN BRANCH 0.311325
AIRLOOP F3 NE MAIN BRANCH 0.190812
AIRLOOP F3 N1 MAIN BRANCH 0.129973
AIRLOOP F3 N2 MAIN BRANCH 0.128502
AIRLOOP F3 S1 MAIN BRANCH 0.248982
AIRLOOP F3 S2 MAIN BRANCH 0.250175
AIRLOOP F4 SW MAIN BRANCH 0.320921
AIRLOOP F4 NW MAIN BRANCH 0.233670
AIRLOOP F4 SE MAIN BRANCH 0.309899
AIRLOOP F4 NE MAIN BRANCH 0.191177
AIRLOOP F4 N1 MAIN BRANCH 0.130771
AIRLOOP F4 N2 MAIN BRANCH 0.129300
AIRLOOP F4 S1 MAIN BRANCH 0.249871
AIRLOOP F4 S2 MAIN BRANCH 0.250884
AIRLOOP M SW MAIN BRANCH 0.322998
AIRLOOP M NW MAIN BRANCH 0.235787
AIRLOOP M SE MAIN BRANCH 0.311915
AIRLOOP M NE MAIN BRANCH 0.193157
AIRLOOP M N1 MAIN BRANCH 0.133050
AIRLOOP M N2 MAIN BRANCH 0.131582
AIRLOOP M S1 MAIN BRANCH 0.252258
AIRLOOP M S2 MAIN BRANCH 0.253243
AIRLOOP F6 SW MAIN BRANCH 0.319338
AIRLOOP F6 NW MAIN BRANCH 0.232157
AIRLOOP F6 SE MAIN BRANCH 0.308433
AIRLOOP F6 NE MAIN BRANCH 0.189541
AIRLOOP F6 N1 MAIN BRANCH 0.129741
AIRLOOP F6 N2 MAIN BRANCH 0.128279
AIRLOOP F6 S1 MAIN BRANCH 0.248844
AIRLOOP F6 S2 MAIN BRANCH 0.249826
AIRLOOP F7 SW MAIN BRANCH 0.317815
AIRLOOP F7 NW MAIN BRANCH 0.230685
AIRLOOP F7 SE MAIN BRANCH 0.307057
AIRLOOP F7 NE MAIN BRANCH 0.188094
AIRLOOP F7 N1 MAIN BRANCH 0.128496
AIRLOOP F7 N2 MAIN BRANCH 0.127040
AIRLOOP F7 S1 MAIN BRANCH 0.247531
AIRLOOP F7 S2 MAIN BRANCH 0.248511
AIRLOOP F8 SW MAIN BRANCH 0.317379
AIRLOOP F8 NW MAIN BRANCH 0.230379
AIRLOOP F8 SE MAIN BRANCH 0.306744
AIRLOOP F8 NE MAIN BRANCH 0.187753
AIRLOOP F8 N1 MAIN BRANCH 0.128448
AIRLOOP F8 N2 MAIN BRANCH 0.126999
AIRLOOP F8 S1 MAIN BRANCH 0.247283
AIRLOOP F8 S2 MAIN BRANCH 0.248264
AIRLOOP F9 SW MAIN BRANCH 0.323540
AIRLOOP F9 NW MAIN BRANCH 0.236842
AIRLOOP F9 SE MAIN BRANCH 0.312150
AIRLOOP F9 NE MAIN BRANCH 0.190196
AIRLOOP F9 N1 MAIN BRANCH 0.134116
AIRLOOP F9 N2 MAIN BRANCH 0.132607
AIRLOOP F9 S1 MAIN BRANCH 0.251727
AIRLOOP F9 S2 MAIN BRANCH 0.252830
AIRLOOP T SW MAIN BRANCH 0.377844
AIRLOOP T NW MAIN BRANCH 0.276439
AIRLOOP T SE MAIN BRANCH 0.359181
AIRLOOP T NE MAIN BRANCH 0.216994
AIRLOOP T N1 MAIN BRANCH 0.146326
AIRLOOP T N2 MAIN BRANCH 0.143566
AIRLOOP T S1 MAIN BRANCH 0.312997
AIRLOOP T S2 MAIN BRANCH 0.314095


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
AIRLOOP G SW 0.237396
AIRLOOP G NW 0.181298
AIRLOOP OFFICE 0.372198
AIRLOOP G NE 0.181218
AIRLOOP G N1 0.134206
AIRLOOP G N2 0.134204
AIRLOOP G S1 0.179553
AIRLOOP G S2 0.186289
AIRLOOP F2 SW 0.317993
AIRLOOP F2 NW 0.229434
AIRLOOP F2 SE 0.329993
AIRLOOP F2 NE 0.186648
AIRLOOP F2 N1 0.125199
AIRLOOP F2 N2 0.123705
AIRLOOP F2 S1 0.244500
AIRLOOP F2 S2 0.246991
AIRLOOP F3 SW 0.320511
AIRLOOP F3 NW 0.233178
AIRLOOP F3 SE 0.311325
AIRLOOP F3 NE 0.190812
AIRLOOP F3 N1 0.129973
AIRLOOP F3 N2 0.128502
AIRLOOP F3 S1 0.248982
AIRLOOP F3 S2 0.250175
AIRLOOP F4 SW 0.320921
AIRLOOP F4 NW 0.233670
AIRLOOP F4 SE 0.309899
AIRLOOP F4 NE 0.191177
AIRLOOP F4 N1 0.130771
AIRLOOP F4 N2 0.129300
AIRLOOP F4 S1 0.249871
AIRLOOP F4 S2 0.250884
AIRLOOP M SW 0.322998
AIRLOOP M NW 0.235787
AIRLOOP M SE 0.311915
AIRLOOP M NE 0.193157
AIRLOOP M N1 0.133050
AIRLOOP M N2 0.131582
AIRLOOP M S1 0.252258
AIRLOOP M S2 0.253243
AIRLOOP F6 SW 0.319338
AIRLOOP F6 NW 0.232157
AIRLOOP F6 SE 0.308433
AIRLOOP F6 NE 0.189541
AIRLOOP F6 N1 0.129741
AIRLOOP F6 N2 0.128279
AIRLOOP F6 S1 0.248844
AIRLOOP F6 S2 0.249826
AIRLOOP F7 SW 0.317815
AIRLOOP F7 NW 0.230685
AIRLOOP F7 SE 0.307057
AIRLOOP F7 NE 0.188094
AIRLOOP F7 N1 0.128496
AIRLOOP F7 N2 0.127040
AIRLOOP F7 S1 0.247531
AIRLOOP F7 S2 0.248511
AIRLOOP F8 SW 0.317379
AIRLOOP F8 NW 0.230379
AIRLOOP F8 SE 0.306744
AIRLOOP F8 NE 0.187753
AIRLOOP F8 N1 0.128448
AIRLOOP F8 N2 0.126999
AIRLOOP F8 S1 0.247283
AIRLOOP F8 S2 0.248264
AIRLOOP F9 SW 0.323540
AIRLOOP F9 NW 0.236842
AIRLOOP F9 SE 0.312150
AIRLOOP F9 NE 0.190196
AIRLOOP F9 N1 0.134116
AIRLOOP F9 N2 0.132607
AIRLOOP F9 S1 0.251727
AIRLOOP F9 S2 0.252830
AIRLOOP T SW 0.377844
AIRLOOP T NW 0.276439
AIRLOOP T SE 0.359181
AIRLOOP T NE 0.216994
AIRLOOP T N1 0.146326
AIRLOOP T N2 0.143566
AIRLOOP T S1 0.312997
AIRLOOP T S2 0.314095


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
AIRLOOP G SW OA CONTROLLER 0.237396 0.025952
AIRLOOP G NW OA CONTROLLER 0.181298 0.025952
AIRLOOP OFFICE OA CONTROLLER 0.372198 0.038103
AIRLOOP G NE OA CONTROLLER 0.181218 0.025952
AIRLOOP G N1 OA CONTROLLER 0.134206 0.025952
AIRLOOP G N2 OA CONTROLLER 0.134204 0.025952
AIRLOOP G S1 OA CONTROLLER 0.179553 0.025952
AIRLOOP G S2 OA CONTROLLER 0.186289 0.025952
AIRLOOP F2 SW OA CONTROLLER 0.317993 0.025952
AIRLOOP F2 NW OA CONTROLLER 0.229434 0.025952
AIRLOOP F2 SE OA CONTROLLER 0.329993 0.025952
AIRLOOP F2 NE OA CONTROLLER 0.186648 0.025952
AIRLOOP F2 N1 OA CONTROLLER 0.125199 0.025952
AIRLOOP F2 N2 OA CONTROLLER 0.123705 0.025952
AIRLOOP F2 S1 OA CONTROLLER 0.244500 0.025952
AIRLOOP F2 S2 OA CONTROLLER 0.246991 0.025952
AIRLOOP F3 SW OA CONTROLLER 0.320511 0.025952
AIRLOOP F3 NW OA CONTROLLER 0.233178 0.025952
AIRLOOP F3 SE OA CONTROLLER 0.311325 0.025952
AIRLOOP F3 NE OA CONTROLLER 0.190812 0.025952
AIRLOOP F3 N1 OA CONTROLLER 0.129973 0.025952
AIRLOOP F3 N2 OA CONTROLLER 0.128502 0.025952
AIRLOOP F3 S1 OA CONTROLLER 0.248982 0.025952
AIRLOOP F3 S2 OA CONTROLLER 0.250175 0.025952
AIRLOOP F4 SW OA CONTROLLER 0.320921 0.025952
AIRLOOP F4 NW OA CONTROLLER 0.233670 0.025952
AIRLOOP F4 SE OA CONTROLLER 0.309899 0.025952
AIRLOOP F4 NE OA CONTROLLER 0.191177 0.025952
AIRLOOP F4 N1 OA CONTROLLER 0.130771 0.025952
AIRLOOP F4 N2 OA CONTROLLER 0.129300 0.025952
AIRLOOP F4 S1 OA CONTROLLER 0.249871 0.025952
AIRLOOP F4 S2 OA CONTROLLER 0.250884 0.025952
AIRLOOP M SW OA CONTROLLER 0.322998 0.025952
AIRLOOP M NW OA CONTROLLER 0.235787 0.025952
AIRLOOP M SE OA CONTROLLER 0.311915 0.025952
AIRLOOP M NE OA CONTROLLER 0.193157 0.025952
AIRLOOP M N1 OA CONTROLLER 0.133050 0.025952
AIRLOOP M N2 OA CONTROLLER 0.131582 0.025952
AIRLOOP M S1 OA CONTROLLER 0.252258 0.025952
AIRLOOP M S2 OA CONTROLLER 0.253243 0.025952
AIRLOOP F6 SW OA CONTROLLER 0.319338 0.025952
AIRLOOP F6 NW OA CONTROLLER 0.232157 0.025952
AIRLOOP F6 SE OA CONTROLLER 0.308433 0.025952
AIRLOOP F6 NE OA CONTROLLER 0.189541 0.025952
AIRLOOP F6 N1 OA CONTROLLER 0.129741 0.025952
AIRLOOP F6 N2 OA CONTROLLER 0.128279 0.025952
AIRLOOP F6 S1 OA CONTROLLER 0.248844 0.025952
AIRLOOP F6 S2 OA CONTROLLER 0.249826 0.025952
AIRLOOP F7 SW OA CONTROLLER 0.317815 0.025952
AIRLOOP F7 NW OA CONTROLLER 0.230685 0.025952
AIRLOOP F7 SE OA CONTROLLER 0.307057 0.025952
AIRLOOP F7 NE OA CONTROLLER 0.188094 0.025952
AIRLOOP F7 N1 OA CONTROLLER 0.128496 0.025952
AIRLOOP F7 N2 OA CONTROLLER 0.127040 0.025952
AIRLOOP F7 S1 OA CONTROLLER 0.247531 0.025952
AIRLOOP F7 S2 OA CONTROLLER 0.248511 0.025952
AIRLOOP F8 SW OA CONTROLLER 0.317379 0.025952
AIRLOOP F8 NW OA CONTROLLER 0.230379 0.025952
AIRLOOP F8 SE OA CONTROLLER 0.306744 0.025952
AIRLOOP F8 NE OA CONTROLLER 0.187753 0.025952
AIRLOOP F8 N1 OA CONTROLLER 0.128448 0.025952
AIRLOOP F8 N2 OA CONTROLLER 0.126999 0.025952
AIRLOOP F8 S1 OA CONTROLLER 0.247283 0.025952
AIRLOOP F8 S2 OA CONTROLLER 0.248264 0.025952
AIRLOOP F9 SW OA CONTROLLER 0.323540 0.025952
AIRLOOP F9 NW OA CONTROLLER 0.236842 0.025952
AIRLOOP F9 SE OA CONTROLLER 0.312150 0.025952
AIRLOOP F9 NE OA CONTROLLER 0.190196 0.025952
AIRLOOP F9 N1 OA CONTROLLER 0.134116 0.025952
AIRLOOP F9 N2 OA CONTROLLER 0.132607 0.025952
AIRLOOP F9 S1 OA CONTROLLER 0.251727 0.025952
AIRLOOP F9 S2 OA CONTROLLER 0.252830 0.025952
AIRLOOP T SW OA CONTROLLER 0.377844 0.025952
AIRLOOP T NW OA CONTROLLER 0.276439 0.025952
AIRLOOP T SE OA CONTROLLER 0.359181 0.025952
AIRLOOP T NE OA CONTROLLER 0.216994 0.025952
AIRLOOP T N1 OA CONTROLLER 0.146326 0.025952
AIRLOOP T N2 OA CONTROLLER 0.143566 0.025952
AIRLOOP T S1 OA CONTROLLER 0.312997 0.025952
AIRLOOP T S2 OA CONTROLLER 0.314095 0.025952


COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity [W] Rated Sensible Cooling Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP COOLING MODE AIRLOOP G SW 0.237396 3265.29 2545.80 0.000071
HEAT PUMP COOLING MODE AIRLOOP G NW 0.181298 2420.70 1906.71 0.000053
HEAT PUMP COOLING MODE AIRLOOP OFFICE 0.372198 5143.49 4004.00 0.000112
HEAT PUMP COOLING MODE AIRLOOP G NE 0.181218 2383.21 1903.52 0.000052
HEAT PUMP COOLING MODE AIRLOOP G N1 0.134206 1619.08 1332.09 0.000035
HEAT PUMP COOLING MODE AIRLOOP G N2 0.134204 1613.17 1329.66 0.000035
HEAT PUMP COOLING MODE AIRLOOP G S1 0.179553 2499.75 1941.97 0.000055
HEAT PUMP COOLING MODE AIRLOOP G S2 0.186289 2593.10 2013.98 0.000057
HEAT PUMP COOLING MODE AIRLOOP F2 SW 0.317993 4363.84 3401.16 0.000095
HEAT PUMP COOLING MODE AIRLOOP F2 NW 0.229434 3088.38 2421.98 0.000067
HEAT PUMP COOLING MODE AIRLOOP F2 SE 0.329993 4559.12 3543.62 0.000100
HEAT PUMP COOLING MODE AIRLOOP F2 NE 0.186648 2482.40 1967.78 0.000054
HEAT PUMP COOLING MODE AIRLOOP F2 N1 0.125199 1592.03 1277.82 0.000035
HEAT PUMP COOLING MODE AIRLOOP F2 N2 0.123705 1571.16 1261.79 0.000034
HEAT PUMP COOLING MODE AIRLOOP F2 S1 0.244500 3391.90 2634.25 0.000074
HEAT PUMP COOLING MODE AIRLOOP F2 S2 0.246991 3426.42 2660.88 0.000075
HEAT PUMP COOLING MODE AIRLOOP F3 SW 0.320511 4395.62 3428.70 0.000096
HEAT PUMP COOLING MODE AIRLOOP F3 NW 0.233178 3132.65 2460.09 0.000068
HEAT PUMP COOLING MODE AIRLOOP F3 SE 0.311325 4292.86 3342.20 0.000094
HEAT PUMP COOLING MODE AIRLOOP F3 NE 0.190812 2532.79 2010.47 0.000055
HEAT PUMP COOLING MODE AIRLOOP F3 N1 0.129973 1653.88 1327.82 0.000036
HEAT PUMP COOLING MODE AIRLOOP F3 N2 0.128502 1633.37 1312.06 0.000036
HEAT PUMP COOLING MODE AIRLOOP F3 S1 0.248982 3449.28 2680.97 0.000075
HEAT PUMP COOLING MODE AIRLOOP F3 S2 0.250175 3465.81 2693.72 0.000076
HEAT PUMP COOLING MODE AIRLOOP F4 SW 0.320921 4395.47 3431.61 0.000096
HEAT PUMP COOLING MODE AIRLOOP F4 NW 0.233670 3133.71 2463.92 0.000068
HEAT PUMP COOLING MODE AIRLOOP F4 SE 0.309899 4267.37 3325.53 0.000093
HEAT PUMP COOLING MODE AIRLOOP F4 NE 0.191177 2532.55 2013.07 0.000055
HEAT PUMP COOLING MODE AIRLOOP F4 N1 0.130771 1661.47 1335.50 0.000036
HEAT PUMP COOLING MODE AIRLOOP F4 N2 0.129300 1640.97 1319.75 0.000036
HEAT PUMP COOLING MODE AIRLOOP F4 S1 0.249871 3458.07 2689.59 0.000076
HEAT PUMP COOLING MODE AIRLOOP F4 S2 0.250884 3472.10 2700.42 0.000076
HEAT PUMP COOLING MODE AIRLOOP M SW 0.322998 4419.48 3452.62 0.000097
HEAT PUMP COOLING MODE AIRLOOP M NW 0.235787 3158.44 2485.40 0.000069
HEAT PUMP COOLING MODE AIRLOOP M SE 0.311915 4290.57 3345.89 0.000094
HEAT PUMP COOLING MODE AIRLOOP M NE 0.193157 2555.59 2033.14 0.000056
HEAT PUMP COOLING MODE AIRLOOP M N1 0.133050 1690.38 1359.23 0.000037
HEAT PUMP COOLING MODE AIRLOOP M N2 0.131582 1669.93 1343.50 0.000036
HEAT PUMP COOLING MODE AIRLOOP M S1 0.252258 3488.24 2714.37 0.000076
HEAT PUMP COOLING MODE AIRLOOP M S2 0.253243 3501.89 2724.90 0.000076
HEAT PUMP COOLING MODE AIRLOOP F6 SW 0.319338 4364.80 3412.52 0.000095
HEAT PUMP COOLING MODE AIRLOOP F6 NW 0.232157 3104.02 2445.58 0.000068
HEAT PUMP COOLING MODE AIRLOOP F6 SE 0.308433 4238.42 3307.71 0.000093
HEAT PUMP COOLING MODE AIRLOOP F6 NE 0.189541 2502.11 1993.68 0.000055
HEAT PUMP COOLING MODE AIRLOOP F6 N1 0.129741 1641.83 1323.18 0.000036
HEAT PUMP COOLING MODE AIRLOOP F6 N2 0.128279 1621.47 1307.52 0.000035
HEAT PUMP COOLING MODE AIRLOOP F6 S1 0.248844 3438.51 2677.28 0.000075
HEAT PUMP COOLING MODE AIRLOOP F6 S2 0.249826 3452.12 2687.78 0.000075
HEAT PUMP COOLING MODE AIRLOOP F7 SW 0.317815 4340.19 3395.37 0.000095
HEAT PUMP COOLING MODE AIRLOOP F7 NW 0.230685 3080.11 2428.98 0.000067
HEAT PUMP COOLING MODE AIRLOOP F7 SE 0.307057 4215.88 3292.13 0.000092
HEAT PUMP COOLING MODE AIRLOOP F7 NE 0.188094 2490.45 1983.01 0.000054
HEAT PUMP COOLING MODE AIRLOOP F7 N1 0.128496 1622.39 1309.33 0.000035
HEAT PUMP COOLING MODE AIRLOOP F7 N2 0.127040 1602.10 1293.73 0.000035
HEAT PUMP COOLING MODE AIRLOOP F7 S1 0.247531 3418.17 2662.70 0.000075
HEAT PUMP COOLING MODE AIRLOOP F7 S2 0.248511 3431.75 2673.18 0.000075
HEAT PUMP COOLING MODE AIRLOOP F8 SW 0.317379 4331.01 3389.93 0.000095
HEAT PUMP COOLING MODE AIRLOOP F8 NW 0.230379 3072.78 2424.94 0.000067
HEAT PUMP COOLING MODE AIRLOOP F8 SE 0.306744 4208.44 3288.01 0.000092
HEAT PUMP COOLING MODE AIRLOOP F8 NE 0.187753 2482.97 1978.69 0.000054
HEAT PUMP COOLING MODE AIRLOOP F8 N1 0.128448 1619.84 1308.36 0.000035
HEAT PUMP COOLING MODE AIRLOOP F8 N2 0.126999 1599.67 1292.84 0.000035
HEAT PUMP COOLING MODE AIRLOOP F8 S1 0.247283 3412.81 2659.58 0.000075
HEAT PUMP COOLING MODE AIRLOOP F8 S2 0.248264 3426.40 2670.06 0.000075
HEAT PUMP COOLING MODE AIRLOOP F9 SW 0.323540 4408.67 3452.45 0.000096
HEAT PUMP COOLING MODE AIRLOOP F9 NW 0.236842 3159.65 2493.34 0.000069
HEAT PUMP COOLING MODE AIRLOOP F9 SE 0.312150 4280.34 3345.04 0.000094
HEAT PUMP COOLING MODE AIRLOOP F9 NE 0.190196 2514.10 2004.13 0.000055
HEAT PUMP COOLING MODE AIRLOOP F9 N1 0.134116 1697.06 1368.64 0.000037
HEAT PUMP COOLING MODE AIRLOOP F9 N2 0.132607 1676.06 1352.49 0.000037
HEAT PUMP COOLING MODE AIRLOOP F9 S1 0.251727 3472.54 2706.62 0.000076
HEAT PUMP COOLING MODE AIRLOOP F9 S2 0.252830 3487.82 2718.40 0.000076
HEAT PUMP COOLING MODE AIRLOOP T SW 0.377844 5172.71 4039.50 0.000113
HEAT PUMP COOLING MODE AIRLOOP T NW 0.276439 3727.97 2932.23 0.000081
HEAT PUMP COOLING MODE AIRLOOP T SE 0.359181 4928.12 3846.69 0.000108
HEAT PUMP COOLING MODE AIRLOOP T NE 0.216994 2892.70 2294.93 0.000063
HEAT PUMP COOLING MODE AIRLOOP T N1 0.146326 1879.16 1505.98 0.000041
HEAT PUMP COOLING MODE AIRLOOP T N2 0.143566 1914.77 1519.41 0.000042
HEAT PUMP COOLING MODE AIRLOOP T S1 0.312997 4319.07 3360.83 0.000094
HEAT PUMP COOLING MODE AIRLOOP T S2 0.314095 4334.29 3372.57 0.000095


AirLoopHVAC:UnitaryHeatPump:WaterToAir

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Supplemental Heating Coil Nominal Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
AIRLOOP G SW DXAC HEAT PUMP 0.237396 0.237396 0.237396 0.237396 3265.29 3265.29 5905.22 1.00
AIRLOOP G NW DXAC HEAT PUMP 0.181298 0.181298 0.181298 0.181298 2420.70 2420.70 5918.27 1.00
AIRLOOP OFFICE DXAC HEAT PUMP 0.372198 0.372198 0.372198 0.372198 5143.49 5143.49 7328.82 1.00
AIRLOOP G NE DXAC HEAT PUMP 0.181218 0.181218 0.181218 0.181218 2383.21 2383.21 5916.51 1.00
AIRLOOP G N1 DXAC HEAT PUMP 0.134206 0.134206 0.134206 0.134206 1619.08 1619.08 4891.70 1.00
AIRLOOP G N2 DXAC HEAT PUMP 0.134204 0.134204 0.134204 0.134204 1613.17 1613.17 4891.66 1.00
AIRLOOP G S1 DXAC HEAT PUMP 0.179553 0.179553 0.179553 0.179553 2499.75 2499.75 4877.08 1.00
AIRLOOP G S2 DXAC HEAT PUMP 0.186289 0.186289 0.186289 0.186289 2593.10 2593.10 4883.34 1.00
AIRLOOP F2 SW DXAC HEAT PUMP 0.317993 0.317993 0.317993 0.317993 4363.84 4363.84 4951.99 1.00
AIRLOOP F2 NW DXAC HEAT PUMP 0.229434 0.229434 0.229434 0.229434 3088.38 3088.38 4945.96 1.00
AIRLOOP F2 SE DXAC HEAT PUMP 0.329993 0.329993 0.329993 0.329993 4559.12 4559.12 4966.93 1.00
AIRLOOP F2 NE DXAC HEAT PUMP 0.186648 0.186648 0.186648 0.186648 2482.40 2482.40 4943.19 1.00
AIRLOOP F2 N1 DXAC HEAT PUMP 0.125199 0.125199 0.125199 0.125199 1592.03 1592.03 3763.43 1.00
AIRLOOP F2 N2 DXAC HEAT PUMP 0.123705 0.123705 0.123705 0.123705 1571.16 1571.16 3763.37 1.00
AIRLOOP F2 S1 DXAC HEAT PUMP 0.244500 0.244500 0.244500 0.244500 3391.90 3391.90 3772.96 1.00
AIRLOOP F2 S2 DXAC HEAT PUMP 0.246991 0.246991 0.246991 0.246991 3426.42 3426.42 3773.94 1.00
AIRLOOP F3 SW DXAC HEAT PUMP 0.320511 0.320511 0.320511 0.320511 4395.62 4395.62 4745.26 1.00
AIRLOOP F3 NW DXAC HEAT PUMP 0.233178 0.233178 0.233178 0.233178 3132.65 3132.65 4741.48 1.00
AIRLOOP F3 SE DXAC HEAT PUMP 0.311325 0.311325 0.311325 0.311325 4292.86 4292.86 4743.72 1.00
AIRLOOP F3 NE DXAC HEAT PUMP 0.190812 0.190812 0.190812 0.190812 2532.79 2532.79 4738.20 1.00
AIRLOOP F3 N1 DXAC HEAT PUMP 0.129973 0.129973 0.129973 0.129973 1653.88 1653.88 3551.20 1.00
AIRLOOP F3 N2 DXAC HEAT PUMP 0.128502 0.128502 0.128502 0.128502 1633.37 1633.37 3551.13 1.00
AIRLOOP F3 S1 DXAC HEAT PUMP 0.248982 0.248982 0.248982 0.248982 3449.28 3449.28 3556.57 1.00
AIRLOOP F3 S2 DXAC HEAT PUMP 0.250175 0.250175 0.250175 0.250175 3465.81 3465.81 3556.65 1.00
AIRLOOP F4 SW DXAC HEAT PUMP 0.320921 0.320921 0.320921 0.320921 4395.47 4395.47 4721.83 1.00
AIRLOOP F4 NW DXAC HEAT PUMP 0.233670 0.233670 0.233670 0.233670 3133.71 3133.71 4718.56 1.00
AIRLOOP F4 SE DXAC HEAT PUMP 0.309899 0.309899 0.309899 0.309899 4267.37 4267.37 4718.33 1.00
AIRLOOP F4 NE DXAC HEAT PUMP 0.191177 0.191177 0.191177 0.191177 2532.55 2532.55 4714.89 1.00
AIRLOOP F4 N1 DXAC HEAT PUMP 0.130771 0.130771 0.130771 0.130771 1661.47 1661.47 3517.34 1.00
AIRLOOP F4 N2 DXAC HEAT PUMP 0.129300 0.129300 0.129300 0.129300 1640.97 1640.97 3517.26 1.00
AIRLOOP F4 S1 DXAC HEAT PUMP 0.249871 0.249871 0.249871 0.249871 3458.07 3458.07 3521.90 1.00
AIRLOOP F4 S2 DXAC HEAT PUMP 0.250884 0.250884 0.250884 0.250884 3472.10 3472.10 3521.84 1.00
AIRLOOP M SW DXAC HEAT PUMP 0.322998 0.322998 0.322998 0.322998 4419.48 4419.48 4702.63 1.00
AIRLOOP M NW DXAC HEAT PUMP 0.235787 0.235787 0.235787 0.235787 3158.44 3158.44 4698.25 1.00
AIRLOOP M SE DXAC HEAT PUMP 0.311915 0.311915 0.311915 0.311915 4290.57 4290.57 4698.68 1.00
AIRLOOP M NE DXAC HEAT PUMP 0.193157 0.193157 0.193157 0.193157 2555.59 2555.59 4694.28 1.00
AIRLOOP M N1 DXAC HEAT PUMP 0.133050 0.133050 0.133050 0.133050 1690.38 1690.38 3490.36 1.00
AIRLOOP M N2 DXAC HEAT PUMP 0.131582 0.131582 0.131582 0.131582 1669.93 1669.93 3490.28 1.00
AIRLOOP M S1 DXAC HEAT PUMP 0.252258 0.252258 0.252258 0.252258 3488.24 3488.24 3496.11 1.00
AIRLOOP M S2 DXAC HEAT PUMP 0.253243 0.253243 0.253243 0.253243 3501.89 3501.89 3496.03 1.00
AIRLOOP F6 SW DXAC HEAT PUMP 0.319338 0.319338 0.319338 0.319338 4364.80 4364.80 4754.51 1.00
AIRLOOP F6 NW DXAC HEAT PUMP 0.232157 0.232157 0.232157 0.232157 3104.02 3104.02 4750.51 1.00
AIRLOOP F6 SE DXAC HEAT PUMP 0.308433 0.308433 0.308433 0.308433 4238.42 4238.42 4750.28 1.00
AIRLOOP F6 NE DXAC HEAT PUMP 0.189541 0.189541 0.189541 0.189541 2502.11 2502.11 4746.27 1.00
AIRLOOP F6 N1 DXAC HEAT PUMP 0.129741 0.129741 0.129741 0.129741 1641.83 1641.83 3533.67 1.00
AIRLOOP F6 N2 DXAC HEAT PUMP 0.128279 0.128279 0.128279 0.128279 1621.47 1621.47 3533.58 1.00
AIRLOOP F6 S1 DXAC HEAT PUMP 0.248844 0.248844 0.248844 0.248844 3438.51 3438.51 3538.90 1.00
AIRLOOP F6 S2 DXAC HEAT PUMP 0.249826 0.249826 0.249826 0.249826 3452.12 3452.12 3538.81 1.00
AIRLOOP F7 SW DXAC HEAT PUMP 0.317815 0.317815 0.317815 0.317815 4340.19 4340.19 4783.04 1.00
AIRLOOP F7 NW DXAC HEAT PUMP 0.230685 0.230685 0.230685 0.230685 3080.11 3080.11 4778.47 1.00
AIRLOOP F7 SE DXAC HEAT PUMP 0.307057 0.307057 0.307057 0.307057 4215.88 4215.88 4778.58 1.00
AIRLOOP F7 NE DXAC HEAT PUMP 0.188094 0.188094 0.188094 0.188094 2490.45 2490.45 4774.01 1.00
AIRLOOP F7 N1 DXAC HEAT PUMP 0.128496 0.128496 0.128496 0.128496 1622.39 1622.39 3555.95 1.00
AIRLOOP F7 N2 DXAC HEAT PUMP 0.127040 0.127040 0.127040 0.127040 1602.10 1602.10 3555.85 1.00
AIRLOOP F7 S1 DXAC HEAT PUMP 0.247531 0.247531 0.247531 0.247531 3418.17 3418.17 3561.77 1.00
AIRLOOP F7 S2 DXAC HEAT PUMP 0.248511 0.248511 0.248511 0.248511 3431.75 3431.75 3561.68 1.00
AIRLOOP F8 SW DXAC HEAT PUMP 0.317379 0.317379 0.317379 0.317379 4331.01 4331.01 4826.57 1.00
AIRLOOP F8 NW DXAC HEAT PUMP 0.230379 0.230379 0.230379 0.230379 3072.78 3072.78 4821.08 1.00
AIRLOOP F8 SE DXAC HEAT PUMP 0.306744 0.306744 0.306744 0.306744 4208.44 4208.44 4821.92 1.00
AIRLOOP F8 NE DXAC HEAT PUMP 0.187753 0.187753 0.187753 0.187753 2482.97 2482.97 4816.42 1.00
AIRLOOP F8 N1 DXAC HEAT PUMP 0.128448 0.128448 0.128448 0.128448 1619.84 1619.84 3593.90 1.00
AIRLOOP F8 N2 DXAC HEAT PUMP 0.126999 0.126999 0.126999 0.126999 1599.67 1599.67 3593.80 1.00
AIRLOOP F8 S1 DXAC HEAT PUMP 0.247283 0.247283 0.247283 0.247283 3412.81 3412.81 3600.67 1.00
AIRLOOP F8 S2 DXAC HEAT PUMP 0.248264 0.248264 0.248264 0.248264 3426.40 3426.40 3600.58 1.00
AIRLOOP F9 SW DXAC HEAT PUMP 0.323540 0.323540 0.323540 0.323540 4408.67 4408.67 5074.16 1.00
AIRLOOP F9 NW DXAC HEAT PUMP 0.236842 0.236842 0.236842 0.236842 3159.65 3159.65 5064.08 1.00
AIRLOOP F9 SE DXAC HEAT PUMP 0.312150 0.312150 0.312150 0.312150 4280.34 4280.34 5069.28 1.00
AIRLOOP F9 NE DXAC HEAT PUMP 0.190196 0.190196 0.190196 0.190196 2514.10 2514.10 5059.19 1.00
AIRLOOP F9 N1 DXAC HEAT PUMP 0.134116 0.134116 0.134116 0.134116 1697.06 1697.06 3820.24 1.00
AIRLOOP F9 N2 DXAC HEAT PUMP 0.132607 0.132607 0.132607 0.132607 1676.06 1676.06 3820.13 1.00
AIRLOOP F9 S1 DXAC HEAT PUMP 0.251727 0.251727 0.251727 0.251727 3472.54 3472.54 3831.16 1.00
AIRLOOP F9 S2 DXAC HEAT PUMP 0.252830 0.252830 0.252830 0.252830 3487.82 3487.82 3831.06 1.00
AIRLOOP T SW DXAC HEAT PUMP 0.377844 0.377844 0.377844 0.377844 5172.71 5172.71 6182.34 1.00
AIRLOOP T NW DXAC HEAT PUMP 0.276439 0.276439 0.276439 0.276439 3727.97 3727.97 6182.64 1.00
AIRLOOP T SE DXAC HEAT PUMP 0.359181 0.359181 0.359181 0.359181 4928.12 4928.12 6177.58 1.00
AIRLOOP T NE DXAC HEAT PUMP 0.216994 0.216994 0.216994 0.216994 2892.70 2892.70 6177.88 1.00
AIRLOOP T N1 DXAC HEAT PUMP 0.146326 0.146326 0.146326 0.146326 1879.16 1879.16 5008.93 1.00
AIRLOOP T N2 DXAC HEAT PUMP 0.143566 0.143566 0.143566 0.143566 1914.77 1914.77 5008.82 1.00
AIRLOOP T S1 DXAC HEAT PUMP 0.312997 0.312997 0.312997 0.312997 4319.07 4319.07 5006.35 1.00
AIRLOOP T S2 DXAC HEAT PUMP 0.314095 0.314095 0.314095 0.314095 4334.29 4334.29 5006.24 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
AIRLOOP G SW SUPPLY FAN 0.237396
AIRLOOP G NW SUPPLY FAN 0.181298
AIRLOOP OFFICE SUPPLY FAN 0.372198
AIRLOOP G NE SUPPLY FAN 0.181218
AIRLOOP G N1 SUPPLY FAN 0.134206
AIRLOOP G N2 SUPPLY FAN 0.134204
AIRLOOP G S1 SUPPLY FAN 0.179553
AIRLOOP G S2 SUPPLY FAN 0.186289
AIRLOOP F2 SW SUPPLY FAN 0.317993
AIRLOOP F2 NW SUPPLY FAN 0.229434
AIRLOOP F2 SE SUPPLY FAN 0.329993
AIRLOOP F2 NE SUPPLY FAN 0.186648
AIRLOOP F2 N1 SUPPLY FAN 0.125199
AIRLOOP F2 N2 SUPPLY FAN 0.123705
AIRLOOP F2 S1 SUPPLY FAN 0.244500
AIRLOOP F2 S2 SUPPLY FAN 0.246991
AIRLOOP F3 SW SUPPLY FAN 0.320511
AIRLOOP F3 NW SUPPLY FAN 0.233178
AIRLOOP F3 SE SUPPLY FAN 0.311325
AIRLOOP F3 NE SUPPLY FAN 0.190812
AIRLOOP F3 N1 SUPPLY FAN 0.129973
AIRLOOP F3 N2 SUPPLY FAN 0.128502
AIRLOOP F3 S1 SUPPLY FAN 0.248982
AIRLOOP F3 S2 SUPPLY FAN 0.250175
AIRLOOP F4 SW SUPPLY FAN 0.320921
AIRLOOP F4 NW SUPPLY FAN 0.233670
AIRLOOP F4 SE SUPPLY FAN 0.309899
AIRLOOP F4 NE SUPPLY FAN 0.191177
AIRLOOP F4 N1 SUPPLY FAN 0.130771
AIRLOOP F4 N2 SUPPLY FAN 0.129300
AIRLOOP F4 S1 SUPPLY FAN 0.249871
AIRLOOP F4 S2 SUPPLY FAN 0.250884
AIRLOOP M SW SUPPLY FAN 0.322998
AIRLOOP M NW SUPPLY FAN 0.235787
AIRLOOP M SE SUPPLY FAN 0.311915
AIRLOOP M NE SUPPLY FAN 0.193157
AIRLOOP M N1 SUPPLY FAN 0.133050
AIRLOOP M N2 SUPPLY FAN 0.131582
AIRLOOP M S1 SUPPLY FAN 0.252258
AIRLOOP M S2 SUPPLY FAN 0.253243
AIRLOOP F6 SW SUPPLY FAN 0.319338
AIRLOOP F6 NW SUPPLY FAN 0.232157
AIRLOOP F6 SE SUPPLY FAN 0.308433
AIRLOOP F6 NE SUPPLY FAN 0.189541
AIRLOOP F6 N1 SUPPLY FAN 0.129741
AIRLOOP F6 N2 SUPPLY FAN 0.128279
AIRLOOP F6 S1 SUPPLY FAN 0.248844
AIRLOOP F6 S2 SUPPLY FAN 0.249826
AIRLOOP F7 SW SUPPLY FAN 0.317815
AIRLOOP F7 NW SUPPLY FAN 0.230685
AIRLOOP F7 SE SUPPLY FAN 0.307057
AIRLOOP F7 NE SUPPLY FAN 0.188094
AIRLOOP F7 N1 SUPPLY FAN 0.128496
AIRLOOP F7 N2 SUPPLY FAN 0.127040
AIRLOOP F7 S1 SUPPLY FAN 0.247531
AIRLOOP F7 S2 SUPPLY FAN 0.248511
AIRLOOP F8 SW SUPPLY FAN 0.317379
AIRLOOP F8 NW SUPPLY FAN 0.230379
AIRLOOP F8 SE SUPPLY FAN 0.306744
AIRLOOP F8 NE SUPPLY FAN 0.187753
AIRLOOP F8 N1 SUPPLY FAN 0.128448
AIRLOOP F8 N2 SUPPLY FAN 0.126999
AIRLOOP F8 S1 SUPPLY FAN 0.247283
AIRLOOP F8 S2 SUPPLY FAN 0.248264
AIRLOOP F9 SW SUPPLY FAN 0.323540
AIRLOOP F9 NW SUPPLY FAN 0.236842
AIRLOOP F9 SE SUPPLY FAN 0.312150
AIRLOOP F9 NE SUPPLY FAN 0.190196
AIRLOOP F9 N1 SUPPLY FAN 0.134116
AIRLOOP F9 N2 SUPPLY FAN 0.132607
AIRLOOP F9 S1 SUPPLY FAN 0.251727
AIRLOOP F9 S2 SUPPLY FAN 0.252830
AIRLOOP T SW SUPPLY FAN 0.377844
AIRLOOP T NW SUPPLY FAN 0.276439
AIRLOOP T SE SUPPLY FAN 0.359181
AIRLOOP T NE SUPPLY FAN 0.216994
AIRLOOP T N1 SUPPLY FAN 0.146326
AIRLOOP T N2 SUPPLY FAN 0.143566
AIRLOOP T S1 SUPPLY FAN 0.312997
AIRLOOP T S2 SUPPLY FAN 0.314095


COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Heating Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP HEATING MODE AIRLOOP G SW 0.237396 3265.29 0.000071
HEAT PUMP HEATING MODE AIRLOOP G NW 0.181298 2420.70 0.000053
HEAT PUMP HEATING MODE AIRLOOP OFFICE 0.372198 5143.49 0.000112
HEAT PUMP HEATING MODE AIRLOOP G NE 0.181218 2383.21 0.000052
HEAT PUMP HEATING MODE AIRLOOP G N1 0.134206 1619.08 0.000035
HEAT PUMP HEATING MODE AIRLOOP G N2 0.134204 1613.17 0.000035
HEAT PUMP HEATING MODE AIRLOOP G S1 0.179553 2499.75 0.000055
HEAT PUMP HEATING MODE AIRLOOP G S2 0.186289 2593.10 0.000057
HEAT PUMP HEATING MODE AIRLOOP F2 SW 0.317993 4363.84 0.000095
HEAT PUMP HEATING MODE AIRLOOP F2 NW 0.229434 3088.38 0.000067
HEAT PUMP HEATING MODE AIRLOOP F2 SE 0.329993 4559.12 0.000100
HEAT PUMP HEATING MODE AIRLOOP F2 NE 0.186648 2482.40 0.000054
HEAT PUMP HEATING MODE AIRLOOP F2 N1 0.125199 1592.03 0.000035
HEAT PUMP HEATING MODE AIRLOOP F2 N2 0.123705 1571.16 0.000034
HEAT PUMP HEATING MODE AIRLOOP F2 S1 0.244500 3391.90 0.000074
HEAT PUMP HEATING MODE AIRLOOP F2 S2 0.246991 3426.42 0.000075
HEAT PUMP HEATING MODE AIRLOOP F3 SW 0.320511 4395.62 0.000096
HEAT PUMP HEATING MODE AIRLOOP F3 NW 0.233178 3132.65 0.000068
HEAT PUMP HEATING MODE AIRLOOP F3 SE 0.311325 4292.86 0.000094
HEAT PUMP HEATING MODE AIRLOOP F3 NE 0.190812 2532.79 0.000055
HEAT PUMP HEATING MODE AIRLOOP F3 N1 0.129973 1653.88 0.000036
HEAT PUMP HEATING MODE AIRLOOP F3 N2 0.128502 1633.37 0.000036
HEAT PUMP HEATING MODE AIRLOOP F3 S1 0.248982 3449.28 0.000075
HEAT PUMP HEATING MODE AIRLOOP F3 S2 0.250175 3465.81 0.000076
HEAT PUMP HEATING MODE AIRLOOP F4 SW 0.320921 4395.47 0.000096
HEAT PUMP HEATING MODE AIRLOOP F4 NW 0.233670 3133.71 0.000068
HEAT PUMP HEATING MODE AIRLOOP F4 SE 0.309899 4267.37 0.000093
HEAT PUMP HEATING MODE AIRLOOP F4 NE 0.191177 2532.55 0.000055
HEAT PUMP HEATING MODE AIRLOOP F4 N1 0.130771 1661.47 0.000036
HEAT PUMP HEATING MODE AIRLOOP F4 N2 0.129300 1640.97 0.000036
HEAT PUMP HEATING MODE AIRLOOP F4 S1 0.249871 3458.07 0.000076
HEAT PUMP HEATING MODE AIRLOOP F4 S2 0.250884 3472.10 0.000076
HEAT PUMP HEATING MODE AIRLOOP M SW 0.322998 4419.48 0.000097
HEAT PUMP HEATING MODE AIRLOOP M NW 0.235787 3158.44 0.000069
HEAT PUMP HEATING MODE AIRLOOP M SE 0.311915 4290.57 0.000094
HEAT PUMP HEATING MODE AIRLOOP M NE 0.193157 2555.59 0.000056
HEAT PUMP HEATING MODE AIRLOOP M N1 0.133050 1690.38 0.000037
HEAT PUMP HEATING MODE AIRLOOP M N2 0.131582 1669.93 0.000036
HEAT PUMP HEATING MODE AIRLOOP M S1 0.252258 3488.24 0.000076
HEAT PUMP HEATING MODE AIRLOOP M S2 0.253243 3501.89 0.000076
HEAT PUMP HEATING MODE AIRLOOP F6 SW 0.319338 4364.80 0.000095
HEAT PUMP HEATING MODE AIRLOOP F6 NW 0.232157 3104.02 0.000068
HEAT PUMP HEATING MODE AIRLOOP F6 SE 0.308433 4238.42 0.000093
HEAT PUMP HEATING MODE AIRLOOP F6 NE 0.189541 2502.11 0.000055
HEAT PUMP HEATING MODE AIRLOOP F6 N1 0.129741 1641.83 0.000036
HEAT PUMP HEATING MODE AIRLOOP F6 N2 0.128279 1621.47 0.000035
HEAT PUMP HEATING MODE AIRLOOP F6 S1 0.248844 3438.51 0.000075
HEAT PUMP HEATING MODE AIRLOOP F6 S2 0.249826 3452.12 0.000075
HEAT PUMP HEATING MODE AIRLOOP F7 SW 0.317815 4340.19 0.000095
HEAT PUMP HEATING MODE AIRLOOP F7 NW 0.230685 3080.11 0.000067
HEAT PUMP HEATING MODE AIRLOOP F7 SE 0.307057 4215.88 0.000092
HEAT PUMP HEATING MODE AIRLOOP F7 NE 0.188094 2490.45 0.000054
HEAT PUMP HEATING MODE AIRLOOP F7 N1 0.128496 1622.39 0.000035
HEAT PUMP HEATING MODE AIRLOOP F7 N2 0.127040 1602.10 0.000035
HEAT PUMP HEATING MODE AIRLOOP F7 S1 0.247531 3418.17 0.000075
HEAT PUMP HEATING MODE AIRLOOP F7 S2 0.248511 3431.75 0.000075
HEAT PUMP HEATING MODE AIRLOOP F8 SW 0.317379 4331.01 0.000095
HEAT PUMP HEATING MODE AIRLOOP F8 NW 0.230379 3072.78 0.000067
HEAT PUMP HEATING MODE AIRLOOP F8 SE 0.306744 4208.44 0.000092
HEAT PUMP HEATING MODE AIRLOOP F8 NE 0.187753 2482.97 0.000054
HEAT PUMP HEATING MODE AIRLOOP F8 N1 0.128448 1619.84 0.000035
HEAT PUMP HEATING MODE AIRLOOP F8 N2 0.126999 1599.67 0.000035
HEAT PUMP HEATING MODE AIRLOOP F8 S1 0.247283 3412.81 0.000075
HEAT PUMP HEATING MODE AIRLOOP F8 S2 0.248264 3426.40 0.000075
HEAT PUMP HEATING MODE AIRLOOP F9 SW 0.323540 4408.67 0.000096
HEAT PUMP HEATING MODE AIRLOOP F9 NW 0.236842 3159.65 0.000069
HEAT PUMP HEATING MODE AIRLOOP F9 SE 0.312150 4280.34 0.000094
HEAT PUMP HEATING MODE AIRLOOP F9 NE 0.190196 2514.10 0.000055
HEAT PUMP HEATING MODE AIRLOOP F9 N1 0.134116 1697.06 0.000037
HEAT PUMP HEATING MODE AIRLOOP F9 N2 0.132607 1676.06 0.000037
HEAT PUMP HEATING MODE AIRLOOP F9 S1 0.251727 3472.54 0.000076
HEAT PUMP HEATING MODE AIRLOOP F9 S2 0.252830 3487.82 0.000076
HEAT PUMP HEATING MODE AIRLOOP T SW 0.377844 5172.71 0.000113
HEAT PUMP HEATING MODE AIRLOOP T NW 0.276439 3727.97 0.000081
HEAT PUMP HEATING MODE AIRLOOP T SE 0.359181 4928.12 0.000108
HEAT PUMP HEATING MODE AIRLOOP T NE 0.216994 2892.70 0.000063
HEAT PUMP HEATING MODE AIRLOOP T N1 0.146326 1879.16 0.000041
HEAT PUMP HEATING MODE AIRLOOP T N2 0.143566 1914.77 0.000042
HEAT PUMP HEATING MODE AIRLOOP T S1 0.312997 4319.07 0.000094
HEAT PUMP HEATING MODE AIRLOOP T S2 0.314095 4334.29 0.000095


Coil:Heating:Electric

Nominal Capacity [W]
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW 5905.22
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW 5918.27
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE 7328.82
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE 5916.51
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 4891.70
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 4891.66
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 4877.08
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 4883.34
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW 4951.99
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW 4945.96
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE 4966.93
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE 4943.19
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 3763.43
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 3763.37
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 3772.96
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 3773.94
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW 4745.26
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW 4741.48
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE 4743.72
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE 4738.20
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 3551.20
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 3551.13
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 3556.57
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 3556.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW 4721.83
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW 4718.56
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE 4718.33
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE 4714.89
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 3517.34
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 3517.26
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 3521.90
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 3521.84
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW 4702.63
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW 4698.25
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE 4698.68
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE 4694.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 3490.36
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 3490.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 3496.11
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 3496.03
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW 4754.51
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW 4750.51
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE 4750.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE 4746.27
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 3533.67
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 3533.58
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 3538.90
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 3538.81
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW 4783.04
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW 4778.47
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE 4778.58
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE 4774.01
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 3555.95
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 3555.85
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 3561.77
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 3561.68
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW 4826.57
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW 4821.08
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE 4821.92
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE 4816.42
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 3593.90
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 3593.80
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 3600.67
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 3600.58
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW 5074.16
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW 5064.08
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE 5069.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE 5059.19
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 3820.24
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 3820.13
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 3831.16
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 3831.06
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW 6182.34
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW 6182.64
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE 6177.58
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE 6177.88
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 5008.93
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 5008.82
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 5006.35
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 5006.24


PlantLoop

Maximum Loop Flow Rate [m3/s] Plant Loop Volume [m3]
SHWSYS1 0.000289 0.325214
SINGLE WATER PLANT LOOP 0.005384 6.06


Boiler:HotWater

Design Water Flow Rate [m3/s]
CENTRAL BOILER 0.005384


WaterHeater:Mixed

Use Side Design Flow Rate [m3/s]
SHWSYS1 WATER HEATER 0.000289


EvaporativeFluidCooler:SingleSpeed

Design Water Flow Rate [m3/s] Fan Power at Design Air Flow Rate [W] Design Air Flow Rate [m3/s] U-Factor Times Area Value at Design Air Flow Rate [W/C]
CENTRAL TOWER 0.005384 2599.31 6.95 7939.30


Pump:ConstantSpeed

Rated Flow Rate [m3/s] Rated Power Consumption [W]
SHWSYS1 PUMP 0.000289 36.93
PLANT CIRC PUMP 0.005384 1719.50



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW3 |
G WWALL SWA GWINDOW2 |
G NWALL NWA GWINDOW4 |
G WWALL NWA GWINDOW6 |
G SWALL SEA GWINDOW1 |
G EWALL SEA GWINDOW8 |
G NWALL NEA GWINDOW5 |
G EWALL NEA GWINDOW7 |
G NWALL N1A GWINDOW9 |
G NWALL N2A GWINDOW10 |
G SWALL S1A GWINDOW11 |
G SWALL S2A GWINDOW12 |
G WWALL C GWINDOW13 |
G EWALL C ENTRANCE DOOR |
F2 WWALL SWA F2WINDOW2 |
F2 SWALL SWA F2WINDOW3 |
F2 NWALL NWA F2WINDOW4 |
F2 WWALL NWA F2WINDOW6 |
F2 EWALL SEA F2WINDOW8 |
F2 SWALL SEA F2WINDOW1 |
F2 NWALL NEA F2WINDOW5 |
F2 EWALL NEA F2WINDOW7 |
F2 NWALL N1A F2WINDOW9 |
F2 NWALL N2A F2WINDOW10 |
F2 SWALL S1A F2WINDOW11 |
F2 SWALL S2A F2WINDOW12 |
F2 WWALL C F2WINDOW13 |
F2 EWALL C F2WINDOW14 |
F3 WWALL SWA F3WINDOW2 |
F3 SWALL SWA F3WINDOW3 |
F3 NWALL NWA F3WINDOW4 |
F3 WWALL NWA F3WINDOW6 |
F3 EWALL SEA F3WINDOW8 |
F3 SWALL SEA F3WINDOW1 |
F3 NWALL NEA F3WINDOW5 |
F3 EWALL NEA F3WINDOW7 |
F3 NWALL N1A F3WINDOW9 |
F3 NWALL N2A F3WINDOW10 |
F3 SWALL S1A F3WINDOW11 |
F3 SWALL S2A F3WINDOW12 |
F3 WWALL C F3WINDOW13 |
F3 EWALL C F3WINDOW14 |
F4 WWALL SWA F4WINDOW2 |
F4 SWALL SWA F4WINDOW3 |
F4 NWALL NWA F4WINDOW4 |
F4 WWALL NWA F4WINDOW6 |
F4 EWALL SEA F4WINDOW8 |
F4 SWALL SEA F4WINDOW1 |
F4 NWALL NEA F4WINDOW5 |
F4 EWALL NEA F4WINDOW7 |
F4 NWALL N1A F4WINDOW9 |
F4 NWALL N2A F4WINDOW10 |
F4 SWALL S1A F4WINDOW11 |
F4 SWALL S2A F4WINDOW12 |
F4 WWALL C F4WINDOW13 |
F4 EWALL C F4WINDOW14 |
M WWALL SWA MWINDOW2 |
M SWALL SWA MWINDOW3 |
M NWALL NWA MWINDOW4 |
M WWALL NWA MWINDOW6 |
M EWALL SEA MWINDOW8 |
M SWALL SEA MWINDOW1 |
M NWALL NEA MWINDOW5 |
M EWALL NEA MWINDOW7 |
M NWALL N1A MWINDOW9 |
M NWALL N2A MWINDOW10 |
M SWALL S1A MWINDOW11 |
M SWALL S2A MWINDOW12 |
M WWALL C MWINDOW13 |
M EWALL C MWINDOW14 |
F6 WWALL SWA F6WINDOW2 |
F6 SWALL SWA F6WINDOW3 |
F6 NWALL NWA F6WINDOW4 |
F6 WWALL NWA F6WINDOW6 |
F6 EWALL SEA F6WINDOW8 |
F6 SWALL SEA F6WINDOW1 |
F6 NWALL NEA F6WINDOW5 |
F6 EWALL NEA F6WINDOW7 |
F6 NWALL N1A F6WINDOW9 |
F6 NWALL N2A F6WINDOW10 |
F6 SWALL S1A F6WINDOW11 |
F6 SWALL S2A F6WINDOW12 |
F6 WWALL C F6WINDOW13 |
F6 EWALL C F6WINDOW14 |
F7 WWALL SWA F7WINDOW2 |
F7 SWALL SWA F7WINDOW3 |
F7 NWALL NWA F7WINDOW4 |
F7 WWALL NWA F7WINDOW6 |
F7 EWALL SEA F7WINDOW8 |
F7 SWALL SEA F7WINDOW1 |
F7 NWALL NEA F7WINDOW5 |
F7 EWALL NEA F7WINDOW7 |
F7 NWALL N1A F7WINDOW9 |
F7 NWALL N2A F7WINDOW10 |
F7 SWALL S1A F7WINDOW11 |
F7 SWALL S2A F7WINDOW12 |
F7 WWALL C F7WINDOW13 |
F7 EWALL C F7WINDOW14 |
F8 WWALL SWA F8WINDOW2 |
F8 SWALL SWA F8WINDOW3 |
F8 NWALL NWA F8WINDOW4 |
F8 WWALL NWA F8WINDOW6 |
F8 EWALL SEA F8WINDOW8 |
F8 SWALL SEA F8WINDOW1 |
F8 NWALL NEA F8WINDOW5 |
F8 EWALL NEA F8WINDOW7 |
F8 NWALL N1A F8WINDOW9 |
F8 NWALL N2A F8WINDOW10 |
F8 SWALL S1A F8WINDOW11 |
F8 SWALL S2A F8WINDOW12 |
F8 WWALL C F8WINDOW13 |
F8 EWALL C F8WINDOW14 |
F9 WWALL SWA F9WINDOW2 |
F9 SWALL SWA F9WINDOW3 |
F9 NWALL NWA F9WINDOW4 |
F9 WWALL NWA F9WINDOW6 |
F9 EWALL SEA F9WINDOW8 |
F9 SWALL SEA F9WINDOW1 |
F9 NWALL NEA F9WINDOW5 |
F9 EWALL NEA F9WINDOW7 |
F9 NWALL N1A F9WINDOW9 |
F9 NWALL N2A F9WINDOW10 |
F9 SWALL S1A F9WINDOW11 |
F9 SWALL S2A F9WINDOW12 |
F9 WWALL C F9WINDOW13 |
F9 EWALL C F9WINDOW14 |
T WWALL SWA TWINDOW2 |
T SWALL SWA TWINDOW3 |
T NWALL NWA TWINDOW4 |
T WWALL NWA TWINDOW6 |
T EWALL SEA TWINDOW8 |
T SWALL SEA TWINDOW1 |
T NWALL NEA TWINDOW5 |
T EWALL NEA TWINDOW7 |
T NWALL N1A TWINDOW9 |
T NWALL N2A TWINDOW10 |
T SWALL S1A TWINDOW11 |
T SWALL S2A TWINDOW12 |
T WWALL C TWINDOW13 |
T EWALL C TWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.72 -10.3
April 22.26 0.73
May 22.85 10.60
June 23.97 15.96
July 24.10 16.86
August 23.87 14.24
September 22.82 6.72
October 21.75 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.52 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.10 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.80 0.73
May 22.20 10.60
June 23.77 15.96
July 23.96 16.86
August 23.45 14.24
September 22.13 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.30 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 23.96 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.72 -15.4
March 21.85 -10.3
April 22.45 0.73
May 23.33 10.60
June 24.23 15.96
July 24.31 16.86
August 24.15 14.24
September 23.17 6.72
October 21.91 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.69 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.31 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.77 0.73
May 22.46 10.60
June 23.85 15.96
July 24.03 16.86
August 23.55 14.24
September 22.21 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.34 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.03 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.72 0.73
May 22.05 10.60
June 23.66 15.96
July 23.90 16.86
August 23.42 14.24
September 22.16 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.26 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 23.90 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.72 0.73
May 22.07 10.60
June 23.67 15.96
July 23.90 16.86
August 23.43 14.24
September 22.17 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.27 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 23.90 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.72 -10.3
April 22.23 0.73
May 22.80 10.60
June 23.94 15.96
July 24.09 16.86
August 23.93 14.24
September 23.03 6.72
October 21.79 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.53 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.09 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.73 -10.3
April 22.27 0.73
May 22.88 10.60
June 23.98 15.96
July 24.12 16.86
August 23.98 14.24
September 23.09 6.72
October 21.80 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.56 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.12 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 9.76 -17.6
February 10.72 -15.4
March 12.50 -10.3
April 16.34 0.73
May 19.95 10.60
June 22.63 15.96
July 23.16 16.86
August 22.02 14.24
September 18.96 6.72
October 14.68 -3.1
November 10.02 -17.6
December 9.33 -19.3
     
Annual Sum or Average 15.87 -1.4
Minimum of Months 9.33 -19.3
Maximum of Months 23.16 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.79 -10.3
April 22.75 0.73
May 23.81 10.60
June 24.29 15.96
July 24.33 16.86
August 24.20 14.24
September 23.27 6.72
October 21.84 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.76 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.33 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.97 0.73
May 23.05 10.60
June 24.15 15.96
July 24.24 16.86
August 23.83 14.24
September 22.30 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.48 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.24 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.71 -15.4
March 21.84 -10.3
April 22.86 0.73
May 23.97 10.60
June 24.34 15.96
July 24.37 16.86
August 24.27 14.24
September 23.46 6.72
October 21.93 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.83 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.37 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.95 0.73
May 23.26 10.60
June 24.17 15.96
July 24.26 16.86
August 23.85 14.24
September 22.35 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.51 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.26 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.84 0.73
May 22.82 10.60
June 24.05 15.96
July 24.18 16.86
August 23.76 14.24
September 22.30 6.72
October 21.71 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.44 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.18 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.84 0.73
May 22.86 10.60
June 24.06 15.96
July 24.18 16.86
August 23.77 14.24
September 22.31 6.72
October 21.71 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.44 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.18 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.71 -15.4
March 21.84 -10.3
April 22.86 0.73
May 23.89 10.60
June 24.28 15.96
July 24.31 16.86
August 24.24 14.24
September 23.52 6.72
October 21.98 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.82 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.31 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.71 -15.4
March 21.85 -10.3
April 22.88 0.73
May 23.91 10.60
June 24.29 15.96
July 24.32 16.86
August 24.25 14.24
September 23.55 6.72
October 22.00 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.83 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.32 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 CORRIDOR

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 19.83 -17.6
February 20.31 -15.4
March 20.91 -10.3
April 22.57 0.73
May 24.44 10.60
June 25.81 15.96
July 25.93 16.86
August 25.36 14.24
September 23.54 6.72
October 21.30 -3.1
November 20.12 -17.6
December 19.68 -19.3
     
Annual Sum or Average 22.50 -1.4
Minimum of Months 19.68 -19.3
Maximum of Months 25.93 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.80 -10.3
April 22.83 0.73
May 23.93 10.60
June 24.30 15.96
July 24.34 16.86
August 24.21 14.24
September 23.33 6.72
October 21.85 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.79 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.34 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 22.03 0.73
May 23.27 10.60
June 24.16 15.96
July 24.27 16.86
August 23.88 14.24
September 22.34 6.72
October 21.71 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.52 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.27 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.83 -10.3
April 22.86 0.73
May 23.99 10.60
June 24.32 15.96
July 24.36 16.86
August 24.24 14.24
September 23.41 6.72
October 21.90 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.82 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.36 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 22.01 0.73
May 23.44 10.60
June 24.18 15.96
July 24.28 16.86
August 23.89 14.24
September 22.40 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.54 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.28 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.90 0.73
May 23.15 10.60
June 24.10 15.96
July 24.22 16.86
August 23.84 14.24
September 22.38 6.72
October 21.71 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.49 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.22 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.90 0.73
May 23.18 10.60
June 24.10 15.96
July 24.22 16.86
August 23.85 14.24
September 22.39 6.72
October 21.71 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.49 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.22 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.71 -15.4
March 21.88 -10.3
April 23.00 0.73
May 24.05 10.60
June 24.29 15.96
July 24.33 16.86
August 24.27 14.24
September 23.61 6.72
October 22.05 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.86 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.33 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.72 -15.4
March 21.89 -10.3
April 23.01 0.73
May 24.06 10.60
June 24.30 15.96
July 24.33 16.86
August 24.27 14.24
September 23.63 6.72
October 22.06 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.87 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.33 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 CORRIDOR

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.77 -17.6
February 21.22 -15.4
March 21.71 -10.3
April 23.20 0.73
May 25.05 10.60
June 26.12 15.96
July 26.20 16.86
August 25.67 14.24
September 23.94 6.72
October 21.88 -3.1
November 21.10 -17.6
December 20.65 -19.3
     
Annual Sum or Average 23.14 -1.4
Minimum of Months 20.65 -19.3
Maximum of Months 26.20 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.80 -10.3
April 22.81 0.73
May 23.93 10.60
June 24.29 15.96
July 24.35 16.86
August 24.20 14.24
September 23.33 6.72
October 21.84 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.79 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.35 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 22.03 0.73
May 23.32 10.60
June 24.15 15.96
July 24.28 16.86
August 23.89 14.24
September 22.37 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.53 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.28 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.82 -10.3
April 22.83 0.73
May 23.98 10.60
June 24.30 15.96
July 24.36 16.86
August 24.23 14.24
September 23.38 6.72
October 21.88 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.81 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.36 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 22.01 0.73
May 23.48 10.60
June 24.17 15.96
July 24.29 16.86
August 23.90 14.24
September 22.42 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.55 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.29 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.91 0.73
May 23.27 10.60
June 24.10 15.96
July 24.24 16.86
August 23.87 14.24
September 22.42 6.72
October 21.71 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.51 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.24 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.91 0.73
May 23.30 10.60
June 24.10 15.96
July 24.24 16.86
August 23.88 14.24
September 22.44 6.72
October 21.71 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.51 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.24 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.72 -15.4
March 21.88 -10.3
April 23.01 0.73
May 24.08 10.60
June 24.29 15.96
July 24.34 16.86
August 24.27 14.24
September 23.63 6.72
October 22.05 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.87 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.34 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.72 -15.4
March 21.89 -10.3
April 23.01 0.73
May 24.08 10.60
June 24.29 15.96
July 24.34 16.86
August 24.27 14.24
September 23.64 6.72
October 22.06 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.87 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.34 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 CORRIDOR

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.97 -17.6
February 21.42 -15.4
March 21.90 -10.3
April 23.36 0.73
May 25.24 10.60
June 26.22 15.96
July 26.31 16.86
August 25.78 14.24
September 24.08 6.72
October 22.03 -3.1
November 21.32 -17.6
December 20.86 -19.3
     
Annual Sum or Average 23.30 -1.4
Minimum of Months 20.86 -19.3
Maximum of Months 26.31 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.80 -10.3
April 22.79 0.73
May 23.91 10.60
June 24.27 15.96
July 24.34 16.86
August 24.19 14.24
September 23.32 6.72
October 21.84 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.78 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.34 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 22.02 0.73
May 23.30 10.60
June 24.13 15.96
July 24.27 16.86
August 23.87 14.24
September 22.37 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.52 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.27 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.82 -10.3
April 22.81 0.73
May 23.96 10.60
June 24.29 15.96
July 24.36 16.86
August 24.22 14.24
September 23.37 6.72
October 21.87 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.80 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.36 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 22.01 0.73
May 23.46 10.60
June 24.14 15.96
July 24.29 16.86
August 23.88 14.24
September 22.42 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.54 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.29 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.92 0.73
May 23.28 10.60
June 24.08 15.96
July 24.24 16.86
August 23.87 14.24
September 22.44 6.72
October 21.71 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.51 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.24 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.92 0.73
May 23.30 10.60
June 24.09 15.96
July 24.24 16.86
August 23.88 14.24
September 22.46 6.72
October 21.71 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.51 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.24 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.72 -15.4
March 21.89 -10.3
April 23.00 0.73
May 24.07 10.60
June 24.28 15.96
July 24.33 16.86
August 24.27 14.24
September 23.63 6.72
October 22.05 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.87 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.33 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.72 -15.4
March 21.89 -10.3
April 23.00 0.73
May 24.07 10.60
June 24.28 15.96
July 24.34 16.86
August 24.27 14.24
September 23.64 6.72
October 22.05 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.87 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.34 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.57 -17.6
February 22.02 -15.4
March 22.48 -10.3
April 23.90 0.73
May 25.78 10.60
June 26.75 15.96
July 26.86 16.86
August 26.32 14.24
September 24.65 6.72
October 22.62 -3.1
November 21.93 -17.6
December 21.48 -19.3
     
Annual Sum or Average 23.88 -1.4
Minimum of Months 21.48 -19.3
Maximum of Months 26.86 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.79 -10.3
April 22.73 0.73
May 23.83 10.60
June 24.24 15.96
July 24.33 16.86
August 24.14 14.24
September 23.24 6.72
October 21.81 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.75 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.33 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.98 0.73
May 23.16 10.60
June 24.07 15.96
July 24.24 16.86
August 23.78 14.24
September 22.27 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.48 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.24 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.81 -10.3
April 22.75 0.73
May 23.89 10.60
June 24.26 15.96
July 24.35 16.86
August 24.17 14.24
September 23.29 6.72
October 21.84 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.77 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.35 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.97 0.73
May 23.34 10.60
June 24.09 15.96
July 24.26 16.86
August 23.79 14.24
September 22.32 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.50 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.26 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.88 0.73
May 23.13 10.60
June 24.03 15.96
July 24.21 16.86
August 23.79 14.24
September 22.34 6.72
October 21.71 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.47 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.21 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.88 0.73
May 23.16 10.60
June 24.03 15.96
July 24.21 16.86
August 23.79 14.24
September 22.35 6.72
October 21.71 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.48 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.21 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.72 -15.4
March 21.86 -10.3
April 22.93 0.73
May 24.01 10.60
June 24.25 15.96
July 24.32 16.86
August 24.23 14.24
September 23.56 6.72
October 22.00 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.84 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.32 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.72 -15.4
March 21.87 -10.3
April 22.94 0.73
May 24.02 10.60
June 24.25 15.96
July 24.32 16.86
August 24.24 14.24
September 23.57 6.72
October 22.01 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.84 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.32 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 CORRIDOR

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.96 -17.6
February 21.41 -15.4
March 21.86 -10.3
April 23.27 0.73
May 25.12 10.60
June 26.15 15.96
July 26.28 16.86
August 25.70 14.24
September 23.99 6.72
October 21.98 -3.1
November 21.33 -17.6
December 20.86 -19.3
     
Annual Sum or Average 23.25 -1.4
Minimum of Months 20.86 -19.3
Maximum of Months 26.28 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.78 -10.3
April 22.69 0.73
May 23.77 10.60
June 24.21 15.96
July 24.31 16.86
August 24.10 14.24
September 23.18 6.72
October 21.80 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.73 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.31 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.95 0.73
May 23.04 10.60
June 24.03 15.96
July 24.22 16.86
August 23.71 14.24
September 22.20 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.45 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.22 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.80 -10.3
April 22.70 0.73
May 23.83 10.60
June 24.23 15.96
July 24.34 16.86
August 24.14 14.24
September 23.23 6.72
October 21.82 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.75 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.34 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.94 0.73
May 23.24 10.60
June 24.04 15.96
July 24.23 16.86
August 23.72 14.24
September 22.24 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.47 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.23 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.86 0.73
May 23.00 10.60
June 23.98 15.96
July 24.19 16.86
August 23.71 14.24
September 22.26 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.44 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.19 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.86 0.73
May 23.03 10.60
June 23.98 15.96
July 24.19 16.86
August 23.72 14.24
September 22.27 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.44 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.19 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.71 -15.4
March 21.85 -10.3
April 22.89 0.73
May 23.96 10.60
June 24.22 15.96
July 24.31 16.86
August 24.21 14.24
September 23.51 6.72
October 21.96 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.82 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.31 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.72 -15.4
March 21.85 -10.3
April 22.89 0.73
May 23.97 10.60
June 24.23 15.96
July 24.31 16.86
August 24.21 14.24
September 23.52 6.72
October 21.97 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.82 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.31 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 CORRIDOR

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.84 -17.6
February 21.28 -15.4
March 21.72 -10.3
April 23.11 0.73
May 24.93 10.60
June 26.02 15.96
July 26.17 16.86
August 25.56 14.24
September 23.82 6.72
October 21.83 -3.1
November 21.22 -17.6
December 20.74 -19.3
     
Annual Sum or Average 23.12 -1.4
Minimum of Months 20.74 -19.3
Maximum of Months 26.17 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.77 -10.3
April 22.65 0.73
May 23.71 10.60
June 24.18 15.96
July 24.30 16.86
August 24.06 14.24
September 23.11 6.72
October 21.78 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.70 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.30 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.93 0.73
May 22.94 10.60
June 23.99 15.96
July 24.20 16.86
August 23.64 14.24
September 22.15 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.43 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.20 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.79 -10.3
April 22.66 0.73
May 23.78 10.60
June 24.21 15.96
July 24.33 16.86
August 24.10 14.24
September 23.17 6.72
October 21.80 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.73 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.33 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.92 0.73
May 23.15 10.60
June 24.00 15.96
July 24.21 16.86
August 23.65 14.24
September 22.18 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.45 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.21 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.85 0.73
May 22.90 10.60
June 23.94 15.96
July 24.16 16.86
August 23.65 14.24
September 22.20 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.41 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.16 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.85 0.73
May 22.93 10.60
June 23.95 15.96
July 24.17 16.86
August 23.65 14.24
September 22.21 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.42 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.17 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.71 -15.4
March 21.84 -10.3
April 22.84 0.73
May 23.91 10.60
June 24.20 15.96
July 24.30 16.86
August 24.18 14.24
September 23.45 6.72
October 21.93 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.79 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.30 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.71 -15.4
March 21.84 -10.3
April 22.85 0.73
May 23.92 10.60
June 24.20 15.96
July 24.30 16.86
August 24.18 14.24
September 23.46 6.72
October 21.93 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.80 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.30 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 CORRIDOR

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.77 -17.6
February 21.21 -15.4
March 21.64 -10.3
April 23.02 0.73
May 24.82 10.60
June 25.97 15.96
July 26.14 16.86
August 25.48 14.24
September 23.71 6.72
October 21.74 -3.1
November 21.16 -17.6
December 20.67 -19.3
     
Annual Sum or Average 23.04 -1.4
Minimum of Months 20.67 -19.3
Maximum of Months 26.14 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.76 -10.3
April 22.59 0.73
May 23.62 10.60
June 24.15 15.96
July 24.29 16.86
August 24.01 14.24
September 23.00 6.72
October 21.77 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.67 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.29 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.92 0.73
May 22.86 10.60
June 23.95 15.96
July 24.17 16.86
August 23.57 14.24
September 22.10 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.40 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.17 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.78 -10.3
April 22.61 0.73
May 23.72 10.60
June 24.18 15.96
July 24.31 16.86
August 24.05 14.24
September 23.06 6.72
October 21.78 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.70 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.31 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.91 0.73
May 23.07 10.60
June 23.96 15.96
July 24.19 16.86
August 23.58 14.24
September 22.12 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.42 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.19 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.84 0.73
May 22.81 10.60
June 23.90 15.96
July 24.14 16.86
August 23.57 14.24
September 22.12 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.39 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.14 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.84 0.73
May 22.84 10.60
June 23.91 15.96
July 24.14 16.86
August 23.57 14.24
September 22.13 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.39 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.14 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.71 -15.4
March 21.82 -10.3
April 22.78 0.73
May 23.84 10.60
June 24.17 15.96
July 24.29 16.86
August 24.13 14.24
September 23.33 6.72
October 21.88 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.76 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.29 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.71 -15.4
March 21.82 -10.3
April 22.78 0.73
May 23.85 10.60
June 24.18 15.96
July 24.29 16.86
August 24.14 14.24
September 23.34 6.72
October 21.89 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.76 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.29 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 CORRIDOR

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.53 -17.6
February 20.98 -15.4
March 21.44 -10.3
April 22.89 0.73
May 24.71 10.60
June 25.95 15.96
July 26.15 16.86
August 25.41 14.24
September 23.54 6.72
October 21.57 -3.1
November 20.91 -17.6
December 20.42 -19.3
     
Annual Sum or Average 22.89 -1.4
Minimum of Months 20.42 -19.3
Maximum of Months 26.15 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.81 -10.3
April 22.49 0.73
May 23.27 10.60
June 24.00 15.96
July 24.19 16.86
August 23.80 14.24
September 22.70 6.72
October 21.77 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.57 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.19 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.71 -10.3
April 22.00 0.73
May 22.76 10.60
June 23.81 15.96
July 24.04 16.86
August 23.38 14.24
September 22.11 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.37 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.04 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.71 -15.4
March 21.83 -10.3
April 22.51 0.73
May 23.37 10.60
June 24.03 15.96
July 24.21 16.86
August 23.83 14.24
September 22.75 6.72
October 21.78 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.60 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.21 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.71 -10.3
April 21.99 0.73
May 22.93 10.60
June 23.80 15.96
July 24.03 16.86
August 23.37 14.24
September 22.11 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.37 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.03 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.91 0.73
May 22.69 10.60
June 23.76 15.96
July 24.01 16.86
August 23.34 14.24
September 22.07 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.34 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.01 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.70 -15.4
March 21.70 -10.3
April 21.91 0.73
May 22.72 10.60
June 23.76 15.96
July 24.01 16.86
August 23.34 14.24
September 22.07 6.72
October 21.70 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.34 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.01 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.71 -15.4
March 21.87 -10.3
April 22.60 0.73
May 23.46 10.60
June 24.06 15.96
July 24.23 16.86
August 23.96 14.24
September 22.95 6.72
October 21.85 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.66 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.23 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -17.6
February 21.72 -15.4
March 21.88 -10.3
April 22.60 0.73
May 23.47 10.60
June 24.07 15.96
July 24.23 16.86
August 23.97 14.24
September 22.96 6.72
October 21.85 -3.1
November 21.70 -17.6
December 21.70 -19.3
     
Annual Sum or Average 22.66 -1.4
Minimum of Months 21.70 -19.3
Maximum of Months 24.23 16.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 19.87 -17.6
February 20.42 -15.4
March 21.19 -10.3
April 23.03 0.73
May 25.08 10.60
June 26.54 15.96
July 26.74 16.86
August 25.81 14.24
September 23.62 6.72
October 21.43 -3.1
November 20.20 -17.6
December 19.72 -19.3
     
Annual Sum or Average 22.82 -1.4
Minimum of Months 19.72 -19.3
Maximum of Months 26.74 16.86



Table of Contents

Report: COMPONENTS OF PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2015-09-09 19:00:31

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY {AT MAX/MIN} [W] HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W]
January 0.350580E+12 332168.454 28-JAN-23:00 7484.424 29363.654 21186.302 261078.471 0.000 10364.000 1756.430 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
February 0.289188E+12 229090.749 23-FEB-18:00 13120.457 57042.023 21186.302 123633.527 0.000 10364.000 1756.430 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
March 0.283809E+12 164583.444 02-MAR-04:00 7740.608 20063.478 21186.302 102811.346 0.000 10364.000 1756.430 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
April 0.230819E+12 166390.740 02-APR-19:00 14401.373 49889.926 21186.302 67151.404 0.000 10364.000 1756.430 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
May 0.209062E+12 131653.858 31-MAY-16:15 11327.174 57142.088 21186.302 0.000 37046.712 0.000 1756.430 1199.956 0.000 0.000 0.000 0.000 0.000 0.000 0.000
June 0.218332E+12 151594.786 20-JUN-17:15 13120.457 57042.023 21186.302 0.000 54706.090 0.000 1756.430 1795.671 0.000 0.000 0.000 0.000 0.000 0.000 0.000
July 0.235749E+12 153878.273 11-JUL-17:15 13120.457 57042.023 21186.302 0.000 56914.076 0.000 1756.430 1871.173 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 0.221574E+12 151358.450 11-AUG-17:15 13120.457 57042.023 21186.302 0.000 54492.539 0.000 1756.430 1772.887 0.000 0.000 0.000 0.000 0.000 0.000 0.000
September 0.206559E+12 113385.613 08-SEP-16:15 11327.174 57142.088 21186.302 0.000 19260.175 0.000 1756.430 718.247 0.000 0.000 0.000 0.000 0.000 0.000 0.000
October 0.263175E+12 153496.014 31-OCT-07:15 9617.308 41626.099 21186.302 67846.608 0.000 10364.000 1756.430 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
November 0.301050E+12 177744.909 29-NOV-07:00 9533.891 40866.781 21186.302 92970.610 0.000 10364.000 1756.430 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
December 0.347616E+12 192377.725 01-DEC-17:00 11327.174 57142.088 21186.302 88606.572 0.000 10364.000 1756.430 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
                                     
Annual Sum or Average 0.315751E+13                     0.000 0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.206559E+12 113385.613   7484.424 20063.478 21186.302 0.000 0.000 0.000 1756.430 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.350580E+12 332168.454   14401.373 57142.088 21186.302 261078.471 56914.076 10364.000 1756.430 1871.173 0.000 0.000 0.000 0.000 0.000 0.000 0.000



Table of Contents

Report: COMPONENTS OF PEAK GAS DEMAND

For: Meter

Timestamp: 2015-09-09 19:00:31

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC [Invalid/Undefined] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT {AT MAX/MIN} [W] WATERSYSTEMS:GAS {AT MAX/MIN} [W] WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] HEATING:GAS {AT MAX/MIN} [W]
January 0.583800E+12 344253.993 29-JAN-07:00 0.000 0.000 0.000 344253.993 89941.367 89941.367 254312.626
February 0.462208E+12 339615.400 24-FEB-06:45 0.000 0.000 0.000 339615.400 85768.070 85768.070 253847.331
March 0.428552E+12 303863.358 02-MAR-07:00 0.000 0.000 0.000 303863.358 89941.177 89941.177 213922.181
April 0.245888E+12 288700.793 02-APR-06:00 0.000 0.000 0.000 288700.793 89941.375 89941.375 198759.418
May 0.135300E+12 166251.630 27-MAY-10:45 0.000 0.000 0.000 166251.630 71571.265 71571.265 94680.366
June 0.122087E+12 90572.168 09-JUN-06:00 0.000 0.000 0.000 90572.168 90572.168 90572.168 0.000
July 0.121656E+12 87936.208 01-JUL-06:00 0.000 0.000 0.000 87936.208 87936.208 87936.208 0.000
August 0.119507E+12 111761.282 30-AUG-05:30 0.000 0.000 0.000 111761.282 79519.807 79519.807 32241.475
September 0.138837E+12 168164.843 30-SEP-05:30 0.000 0.000 0.000 168164.843 79248.612 79248.612 88916.231
October 0.345326E+12 287119.369 31-OCT-07:30 0.000 0.000 0.000 287119.369 85206.135 85206.135 201913.234
November 0.509973E+12 317154.634 29-NOV-08:15 0.000 0.000 0.000 317154.634 87984.529 87984.529 229170.105
December 0.604656E+12 326154.119 15-DEC-09:15 0.000 0.000 0.000 326154.119 84350.377 84350.377 241803.742
                     
Annual Sum or Average 0.381779E+13     0.000 0.000 0.000        
Minimum of Months 0.119507E+12 87936.208   0.000 0.000 0.000 87936.208 71571.265 71571.265 0.000
Maximum of Months 0.604656E+12 344253.993   0.000 0.000 0.000 344253.993 90572.168 90572.168 254312.626