Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 19:10
Tabular Output Report in Format: HTML
Building: High-Rise Apartment
Environment: Phoenix Sky Harbor Intl Ap AZ USA TMY3 WMO#=722780
Simulation Timestamp: 2015-09-09 19:11:36
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:36
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 4597.73 | 586.71 | 651.25 |
Net Site Energy | 4597.73 | 586.71 | 651.25 |
Total Source Energy | 12762.95 | 1628.66 | 1807.81 |
Net Source Energy | 12762.95 | 1628.66 | 1807.81 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 7836.48 |
Net Conditioned Building Area | 7059.89 |
Unconditioned Building Area | 776.58 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 8.14 | 7.22 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 1085.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 296.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 162.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1137.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 884.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 79.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 44.12 | 0.00 | 0.00 | 0.00 | 0.00 | 4165.15 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 855.99 | 0.00 | 0.00 | 0.00 | 4778.51 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 3734.52 | 863.21 | 0.00 | 0.00 | 0.00 | 8943.67 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Boiler | 0.00 | 7.22 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Other | 8.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 1085.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 242.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 54.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 162.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 1137.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 884.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 79.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 44.12 | 0.00 | 0.00 | 0.00 | 0.00 | 4165.15 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 855.99 | 0.00 | 0.00 | 0.00 | 0.00 |
sub cat | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4778.51 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 65.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 297.70 | 122.27 | 0.00 | 0.00 | 0.00 | 1.27 |
Other | 161.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 528.98 | 122.27 | 0.00 | 0.00 | 0.00 | 1.27 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 58.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 268.20 | 110.15 | 0.00 | 0.00 | 0.00 | 1.14 |
Other | 145.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 476.56 | 110.15 | 0.00 | 0.00 | 0.00 | 1.14 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 3734.52 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 3734.52 | 100.00 |
Total On-Site and Utility Electric Sources | 3734.52 | 100.00 |
Total Electricity End Uses | 3734.52 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 8943.67 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 8943.67 | 100.00 |
Total Water End Uses | 8943.67 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 11.25 |
Time Setpoint Not Met During Occupied Cooling | 362.25 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 175.25 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |COMPONENTS OF PEAK ELECTRICAL DEMAND
| Meter |COMPONENTS OF PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:36
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 19:10 |
RunPeriod | Phoenix Sky Harbor Intl Ap AZ USA TMY3 WMO#=722780 |
Weather File | Phoenix Sky Harbor Intl Ap AZ USA TMY3 WMO#=722780 |
Latitude [deg] | 33.45 |
Longitude [deg] | -112.0 |
Elevation [m] | 337.00 |
Time Zone | -7.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 3855.02 | 1411.96 | 515.55 | 1411.96 | 515.55 |
Window Opening Area [m2] | 1150.39 | 423.59 | 152.73 | 423.59 | 150.48 |
Window-Wall Ratio [%] | 29.84 | 30.00 | 29.62 | 30.00 | 29.19 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 3752.84 | 1411.96 | 464.46 | 1411.96 | 464.46 |
Window Opening Area [m2] | 1125.85 | 423.59 | 139.34 | 423.59 | 139.34 |
Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 29.5362 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 4.47 | 6.7128 | 0.0000 | |
F2 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F3 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F4 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
M SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 13.4255 | 0.0000 | |
F6 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F7 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F8 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F9 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
T SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 264.3872 | |
Total | 7836.48 | 23884.04 | 3855.02 | 1150.39 | 4.3335 | 39.48 | 8.6291 | |||
Conditioned Total | 7059.89 | 21517.16 | 3752.84 | 1125.85 | 3.9979 | 35.57 | 6.6700 | |||
Unconditioned Total | 776.58 | 2366.87 | 102.18 | 24.54 | 7.3840 | 26.4387 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:36
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 07-JUL-17:00 | 10-FEB-07:15 | - | - | - | 16-JUL-17:00 |
Heating | 0.00 | 57375.26 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 90743.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 13120.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 57042.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 28046.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 2563.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 3686.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 73455.30 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 197190.81 | 130830.56 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | Boiler | 0.00 | 57375.26 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 90743.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 10541.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 2579.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 57042.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 28046.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 2563.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 3686.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 73455.30 | 0.00 | 0.00 | 0.00 | 0.00 |
sub cat | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:36
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 25.77 | 7.83 | 0.00 | 0.00 | 0.00 |
Cooling | 3437.49 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 939.20 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 515.42 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 3601.91 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 2801.13 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 252.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 139.73 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 927.90 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 11827.23 | 935.72 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 3.65 | 1.11 | 0.00 | 0.00 | 0.00 |
Cooling | 486.90 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 133.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 73.01 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 510.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 396.77 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 35.70 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 19.79 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 131.43 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1675.27 | 132.54 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 3.65 | 1.11 | 0.00 | 0.00 | 0.00 |
Cooling | 486.90 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 133.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 73.01 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 510.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 396.77 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 35.70 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 19.79 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 131.43 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1675.27 | 132.54 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:36
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 3.70 | 0.00 | 3.70 | Wetbulb [C] | 1.70 | 100.00 |
PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 43.40 | 12.00 | 21.10 | Wetbulb [C] | 4.10 | 260.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:36
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 270.00 | 180.00 | |
F2 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F2 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F2 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F2 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F2 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F2 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F3 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F3 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F3 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F3 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F3 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F3 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F4 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F4 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F4 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F4 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F4 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F4 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F6 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F6 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F6 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F6 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F6 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F6 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F7 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F7 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F7 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F7 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F7 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F7 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F8 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F8 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F8 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F8 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F8 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F8 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F9 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F9 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F9 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F9 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F9 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F9 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.30 | 0.269 | 0.283 | 77.66 | 0.00 | 0.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
GWINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | G WWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_0.72_SHGC_0.25 | 3.36 | 0.00 | 0.00 | 3.36 | 3.36 | 4.600 | 0.293 | 0.130 | No | G EWALL C | 90.00 | 90.00 | E | ||
F2WINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F2 WWALL SWA | 270.00 | 90.00 | W | ||
F2WINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 SWALL SWA | 180.00 | 90.00 | S | ||
F2WINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 NWALL NWA | 0.00 | 90.00 | N | ||
F2WINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F2 WWALL NWA | 270.00 | 90.00 | W | ||
F2WINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F2 EWALL SEA | 90.00 | 90.00 | E | ||
F2WINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 SWALL SEA | 180.00 | 90.00 | S | ||
F2WINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 NWALL NEA | 0.00 | 90.00 | N | ||
F2WINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F2 EWALL NEA | 90.00 | 90.00 | E | ||
F2WINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 NWALL N1A | 0.00 | 90.00 | N | ||
F2WINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 NWALL N2A | 0.00 | 90.00 | N | ||
F2WINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 SWALL S1A | 180.00 | 90.00 | S | ||
F2WINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 SWALL S2A | 180.00 | 90.00 | S | ||
F2WINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F2 WWALL C | 270.00 | 90.00 | W | ||
F2WINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F2 EWALL C | 90.00 | 90.00 | E | ||
F3WINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F3 WWALL SWA | 270.00 | 90.00 | W | ||
F3WINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 SWALL SWA | 180.00 | 90.00 | S | ||
F3WINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 NWALL NWA | 0.00 | 90.00 | N | ||
F3WINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F3 WWALL NWA | 270.00 | 90.00 | W | ||
F3WINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F3 EWALL SEA | 90.00 | 90.00 | E | ||
F3WINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 SWALL SEA | 180.00 | 90.00 | S | ||
F3WINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 NWALL NEA | 0.00 | 90.00 | N | ||
F3WINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F3 EWALL NEA | 90.00 | 90.00 | E | ||
F3WINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 NWALL N1A | 0.00 | 90.00 | N | ||
F3WINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 NWALL N2A | 0.00 | 90.00 | N | ||
F3WINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 SWALL S1A | 180.00 | 90.00 | S | ||
F3WINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 SWALL S2A | 180.00 | 90.00 | S | ||
F3WINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F3 WWALL C | 270.00 | 90.00 | W | ||
F3WINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F3 EWALL C | 90.00 | 90.00 | E | ||
F4WINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F4 WWALL SWA | 270.00 | 90.00 | W | ||
F4WINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 SWALL SWA | 180.00 | 90.00 | S | ||
F4WINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 NWALL NWA | 0.00 | 90.00 | N | ||
F4WINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F4 WWALL NWA | 270.00 | 90.00 | W | ||
F4WINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F4 EWALL SEA | 90.00 | 90.00 | E | ||
F4WINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 SWALL SEA | 180.00 | 90.00 | S | ||
F4WINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 NWALL NEA | 0.00 | 90.00 | N | ||
F4WINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F4 EWALL NEA | 90.00 | 90.00 | E | ||
F4WINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 NWALL N1A | 0.00 | 90.00 | N | ||
F4WINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 NWALL N2A | 0.00 | 90.00 | N | ||
F4WINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 SWALL S1A | 180.00 | 90.00 | S | ||
F4WINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 SWALL S2A | 180.00 | 90.00 | S | ||
F4WINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F4 WWALL C | 270.00 | 90.00 | W | ||
F4WINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F4 EWALL C | 90.00 | 90.00 | E | ||
MWINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | M WWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | M EWALL C | 90.00 | 90.00 | E | ||
F6WINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F6 WWALL SWA | 270.00 | 90.00 | W | ||
F6WINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 SWALL SWA | 180.00 | 90.00 | S | ||
F6WINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 NWALL NWA | 0.00 | 90.00 | N | ||
F6WINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F6 WWALL NWA | 270.00 | 90.00 | W | ||
F6WINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F6 EWALL SEA | 90.00 | 90.00 | E | ||
F6WINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 SWALL SEA | 180.00 | 90.00 | S | ||
F6WINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 NWALL NEA | 0.00 | 90.00 | N | ||
F6WINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F6 EWALL NEA | 90.00 | 90.00 | E | ||
F6WINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 NWALL N1A | 0.00 | 90.00 | N | ||
F6WINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 NWALL N2A | 0.00 | 90.00 | N | ||
F6WINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 SWALL S1A | 180.00 | 90.00 | S | ||
F6WINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 SWALL S2A | 180.00 | 90.00 | S | ||
F6WINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F6 WWALL C | 270.00 | 90.00 | W | ||
F6WINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F6 EWALL C | 90.00 | 90.00 | E | ||
F7WINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F7 WWALL SWA | 270.00 | 90.00 | W | ||
F7WINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 SWALL SWA | 180.00 | 90.00 | S | ||
F7WINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 NWALL NWA | 0.00 | 90.00 | N | ||
F7WINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F7 WWALL NWA | 270.00 | 90.00 | W | ||
F7WINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F7 EWALL SEA | 90.00 | 90.00 | E | ||
F7WINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 SWALL SEA | 180.00 | 90.00 | S | ||
F7WINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 NWALL NEA | 0.00 | 90.00 | N | ||
F7WINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F7 EWALL NEA | 90.00 | 90.00 | E | ||
F7WINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 NWALL N1A | 0.00 | 90.00 | N | ||
F7WINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 NWALL N2A | 0.00 | 90.00 | N | ||
F7WINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 SWALL S1A | 180.00 | 90.00 | S | ||
F7WINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 SWALL S2A | 180.00 | 90.00 | S | ||
F7WINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F7 WWALL C | 270.00 | 90.00 | W | ||
F7WINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F7 EWALL C | 90.00 | 90.00 | E | ||
F8WINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F8 WWALL SWA | 270.00 | 90.00 | W | ||
F8WINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 SWALL SWA | 180.00 | 90.00 | S | ||
F8WINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 NWALL NWA | 0.00 | 90.00 | N | ||
F8WINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F8 WWALL NWA | 270.00 | 90.00 | W | ||
F8WINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F8 EWALL SEA | 90.00 | 90.00 | E | ||
F8WINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 SWALL SEA | 180.00 | 90.00 | S | ||
F8WINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 NWALL NEA | 0.00 | 90.00 | N | ||
F8WINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F8 EWALL NEA | 90.00 | 90.00 | E | ||
F8WINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 NWALL N1A | 0.00 | 90.00 | N | ||
F8WINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 NWALL N2A | 0.00 | 90.00 | N | ||
F8WINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 SWALL S1A | 180.00 | 90.00 | S | ||
F8WINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 SWALL S2A | 180.00 | 90.00 | S | ||
F8WINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F8 WWALL C | 270.00 | 90.00 | W | ||
F8WINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F8 EWALL C | 90.00 | 90.00 | E | ||
F9WINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F9 WWALL SWA | 270.00 | 90.00 | W | ||
F9WINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 SWALL SWA | 180.00 | 90.00 | S | ||
F9WINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 NWALL NWA | 0.00 | 90.00 | N | ||
F9WINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F9 WWALL NWA | 270.00 | 90.00 | W | ||
F9WINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F9 EWALL SEA | 90.00 | 90.00 | E | ||
F9WINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 SWALL SEA | 180.00 | 90.00 | S | ||
F9WINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 NWALL NEA | 0.00 | 90.00 | N | ||
F9WINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F9 EWALL NEA | 90.00 | 90.00 | E | ||
F9WINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 NWALL N1A | 0.00 | 90.00 | N | ||
F9WINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 NWALL N2A | 0.00 | 90.00 | N | ||
F9WINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 SWALL S1A | 180.00 | 90.00 | S | ||
F9WINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 SWALL S2A | 180.00 | 90.00 | S | ||
F9WINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F9 WWALL C | 270.00 | 90.00 | W | ||
F9WINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F9 EWALL C | 90.00 | 90.00 | E | ||
TWINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | T WWALL C | 270.00 | 90.00 | W | ||
TWINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | T EWALL C | 90.00 | 90.00 | E | ||
Total or Average | 1150.39 | 4.600 | 0.293 | 0.130 | ||||||||||||
North Total or Average | 423.59 | 4.600 | 0.293 | 0.130 | ||||||||||||
Non-North Total or Average | 726.80 | 4.600 | 0.293 | 0.130 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:36
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:36
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
G SW APARTMENT_LIGHTS_HARDWIRED | G SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G NW APARTMENT_LIGHTS_HARDWIRED | G NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
OFFICE_LIGHTS_HARDWIRED | OFFICE | 14.7681 | 88.25 | 1303.26 | GeneralLights | LTG_OFF_SCH | 62.05 | 168.00 | 61.07 | 0.0000 | Y | 14.94 |
G NE APARTMENT_LIGHTS_HARDWIRED | G NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G N1 APARTMENT_LIGHTS_HARDWIRED | G N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G N2 APARTMENT_LIGHTS_HARDWIRED | G N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G S1 APARTMENT_LIGHTS_HARDWIRED | G S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G S2 APARTMENT_LIGHTS_HARDWIRED | G S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G CORRIDOR_LIGHTS_HARDWIRED | G CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F2 SW APARTMENT_LIGHTS_HARDWIRED | F2 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 NW APARTMENT_LIGHTS_HARDWIRED | F2 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 SE APARTMENT_LIGHTS_HARDWIRED | F2 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 NE APARTMENT_LIGHTS_HARDWIRED | F2 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 N1 APARTMENT_LIGHTS_HARDWIRED | F2 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 N2 APARTMENT_LIGHTS_HARDWIRED | F2 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 S1 APARTMENT_LIGHTS_HARDWIRED | F2 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 S2 APARTMENT_LIGHTS_HARDWIRED | F2 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 CORRIDOR_LIGHTS_HARDWIRED | F2 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F3 SW APARTMENT_LIGHTS_HARDWIRED | F3 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 NW APARTMENT_LIGHTS_HARDWIRED | F3 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 SE APARTMENT_LIGHTS_HARDWIRED | F3 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 NE APARTMENT_LIGHTS_HARDWIRED | F3 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 N1 APARTMENT_LIGHTS_HARDWIRED | F3 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 N2 APARTMENT_LIGHTS_HARDWIRED | F3 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 S1 APARTMENT_LIGHTS_HARDWIRED | F3 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 S2 APARTMENT_LIGHTS_HARDWIRED | F3 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 CORRIDOR_LIGHTS_HARDWIRED | F3 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F4 SW APARTMENT_LIGHTS_HARDWIRED | F4 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 NW APARTMENT_LIGHTS_HARDWIRED | F4 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 SE APARTMENT_LIGHTS_HARDWIRED | F4 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 NE APARTMENT_LIGHTS_HARDWIRED | F4 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 N1 APARTMENT_LIGHTS_HARDWIRED | F4 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 N2 APARTMENT_LIGHTS_HARDWIRED | F4 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 S1 APARTMENT_LIGHTS_HARDWIRED | F4 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 S2 APARTMENT_LIGHTS_HARDWIRED | F4 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 CORRIDOR_LIGHTS_HARDWIRED | F4 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
M SW APARTMENT_LIGHTS_HARDWIRED | M SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M NW APARTMENT_LIGHTS_HARDWIRED | M NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M SE APARTMENT_LIGHTS_HARDWIRED | M SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M NE APARTMENT_LIGHTS_HARDWIRED | M NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M N1 APARTMENT_LIGHTS_HARDWIRED | M N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M N2 APARTMENT_LIGHTS_HARDWIRED | M N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M S1 APARTMENT_LIGHTS_HARDWIRED | M S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M S2 APARTMENT_LIGHTS_HARDWIRED | M S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M CORRIDOR_LIGHTS_HARDWIRED | M CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F6 SW APARTMENT_LIGHTS_HARDWIRED | F6 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 NW APARTMENT_LIGHTS_HARDWIRED | F6 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 SE APARTMENT_LIGHTS_HARDWIRED | F6 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 NE APARTMENT_LIGHTS_HARDWIRED | F6 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 N1 APARTMENT_LIGHTS_HARDWIRED | F6 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 N2 APARTMENT_LIGHTS_HARDWIRED | F6 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 S1 APARTMENT_LIGHTS_HARDWIRED | F6 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 S2 APARTMENT_LIGHTS_HARDWIRED | F6 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 CORRIDOR_LIGHTS_HARDWIRED | F6 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F7 SW APARTMENT_LIGHTS_HARDWIRED | F7 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 NW APARTMENT_LIGHTS_HARDWIRED | F7 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 SE APARTMENT_LIGHTS_HARDWIRED | F7 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 NE APARTMENT_LIGHTS_HARDWIRED | F7 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 N1 APARTMENT_LIGHTS_HARDWIRED | F7 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 N2 APARTMENT_LIGHTS_HARDWIRED | F7 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 S1 APARTMENT_LIGHTS_HARDWIRED | F7 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 S2 APARTMENT_LIGHTS_HARDWIRED | F7 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 CORRIDOR_LIGHTS_HARDWIRED | F7 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F8 SW APARTMENT_LIGHTS_HARDWIRED | F8 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 NW APARTMENT_LIGHTS_HARDWIRED | F8 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 SE APARTMENT_LIGHTS_HARDWIRED | F8 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 NE APARTMENT_LIGHTS_HARDWIRED | F8 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 N1 APARTMENT_LIGHTS_HARDWIRED | F8 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 N2 APARTMENT_LIGHTS_HARDWIRED | F8 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 S1 APARTMENT_LIGHTS_HARDWIRED | F8 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 S2 APARTMENT_LIGHTS_HARDWIRED | F8 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 CORRIDOR_LIGHTS_HARDWIRED | F8 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F9 SW APARTMENT_LIGHTS_HARDWIRED | F9 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 NW APARTMENT_LIGHTS_HARDWIRED | F9 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 SE APARTMENT_LIGHTS_HARDWIRED | F9 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 NE APARTMENT_LIGHTS_HARDWIRED | F9 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 N1 APARTMENT_LIGHTS_HARDWIRED | F9 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 N2 APARTMENT_LIGHTS_HARDWIRED | F9 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 S1 APARTMENT_LIGHTS_HARDWIRED | F9 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 S2 APARTMENT_LIGHTS_HARDWIRED | F9 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 CORRIDOR_LIGHTS_HARDWIRED | F9 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
T SW APARTMENT_LIGHTS_HARDWIRED | T SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T NW APARTMENT_LIGHTS_HARDWIRED | T NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T SE APARTMENT_LIGHTS_HARDWIRED | T SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T NE APARTMENT_LIGHTS_HARDWIRED | T NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T N1 APARTMENT_LIGHTS_HARDWIRED | T N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T N2 APARTMENT_LIGHTS_HARDWIRED | T N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T S1 APARTMENT_LIGHTS_HARDWIRED | T S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T S2 APARTMENT_LIGHTS_HARDWIRED | T S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T CORRIDOR_LIGHTS_HARDWIRED | T CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
G SW APARTMENT_LIGHTS_PLUGIN | G SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G NW APARTMENT_LIGHTS_PLUGIN | G NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
OFFICE_LIGHTS_PLUGIN | OFFICE | 14.7681 | 88.25 | 1303.26 | GeneralLights-plugin | LTG_OFF_SCH | 62.05 | 168.00 | 61.07 | 0.0000 | Y | 14.94 |
G NE APARTMENT_LIGHTS_PLUGIN | G NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G N1 APARTMENT_LIGHTS_PLUGIN | G N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G N2 APARTMENT_LIGHTS_PLUGIN | G N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G S1 APARTMENT_LIGHTS_PLUGIN | G S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G S2 APARTMENT_LIGHTS_PLUGIN | G S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 SW APARTMENT_LIGHTS_PLUGIN | F2 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 NW APARTMENT_LIGHTS_PLUGIN | F2 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 SE APARTMENT_LIGHTS_PLUGIN | F2 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 NE APARTMENT_LIGHTS_PLUGIN | F2 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 N1 APARTMENT_LIGHTS_PLUGIN | F2 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 N2 APARTMENT_LIGHTS_PLUGIN | F2 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 S1 APARTMENT_LIGHTS_PLUGIN | F2 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 S2 APARTMENT_LIGHTS_PLUGIN | F2 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 SW APARTMENT_LIGHTS_PLUGIN | F3 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 NW APARTMENT_LIGHTS_PLUGIN | F3 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 SE APARTMENT_LIGHTS_PLUGIN | F3 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 NE APARTMENT_LIGHTS_PLUGIN | F3 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 N1 APARTMENT_LIGHTS_PLUGIN | F3 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 N2 APARTMENT_LIGHTS_PLUGIN | F3 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 S1 APARTMENT_LIGHTS_PLUGIN | F3 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 S2 APARTMENT_LIGHTS_PLUGIN | F3 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 SW APARTMENT_LIGHTS_PLUGIN | F4 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 NW APARTMENT_LIGHTS_PLUGIN | F4 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 SE APARTMENT_LIGHTS_PLUGIN | F4 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 NE APARTMENT_LIGHTS_PLUGIN | F4 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 N1 APARTMENT_LIGHTS_PLUGIN | F4 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 N2 APARTMENT_LIGHTS_PLUGIN | F4 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 S1 APARTMENT_LIGHTS_PLUGIN | F4 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 S2 APARTMENT_LIGHTS_PLUGIN | F4 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M SW APARTMENT_LIGHTS_PLUGIN | M SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M NW APARTMENT_LIGHTS_PLUGIN | M NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M SE APARTMENT_LIGHTS_PLUGIN | M SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M NE APARTMENT_LIGHTS_PLUGIN | M NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M N1 APARTMENT_LIGHTS_PLUGIN | M N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M N2 APARTMENT_LIGHTS_PLUGIN | M N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M S1 APARTMENT_LIGHTS_PLUGIN | M S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M S2 APARTMENT_LIGHTS_PLUGIN | M S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M CORRIDOR_LIGHTS_PLUGIN | M CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights-plugin | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F6 SW APARTMENT_LIGHTS_PLUGIN | F6 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 NW APARTMENT_LIGHTS_PLUGIN | F6 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 SE APARTMENT_LIGHTS_PLUGIN | F6 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 NE APARTMENT_LIGHTS_PLUGIN | F6 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 N1 APARTMENT_LIGHTS_PLUGIN | F6 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 N2 APARTMENT_LIGHTS_PLUGIN | F6 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 S1 APARTMENT_LIGHTS_PLUGIN | F6 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 S2 APARTMENT_LIGHTS_PLUGIN | F6 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 SW APARTMENT_LIGHTS_PLUGIN | F7 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 NW APARTMENT_LIGHTS_PLUGIN | F7 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 SE APARTMENT_LIGHTS_PLUGIN | F7 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 NE APARTMENT_LIGHTS_PLUGIN | F7 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 N1 APARTMENT_LIGHTS_PLUGIN | F7 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 N2 APARTMENT_LIGHTS_PLUGIN | F7 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 S1 APARTMENT_LIGHTS_PLUGIN | F7 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 S2 APARTMENT_LIGHTS_PLUGIN | F7 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 SW APARTMENT_LIGHTS_PLUGIN | F8 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 NW APARTMENT_LIGHTS_PLUGIN | F8 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 SE APARTMENT_LIGHTS_PLUGIN | F8 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 NE APARTMENT_LIGHTS_PLUGIN | F8 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 N1 APARTMENT_LIGHTS_PLUGIN | F8 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 N2 APARTMENT_LIGHTS_PLUGIN | F8 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 S1 APARTMENT_LIGHTS_PLUGIN | F8 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 S2 APARTMENT_LIGHTS_PLUGIN | F8 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 SW APARTMENT_LIGHTS_PLUGIN | F9 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 NW APARTMENT_LIGHTS_PLUGIN | F9 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 SE APARTMENT_LIGHTS_PLUGIN | F9 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 NE APARTMENT_LIGHTS_PLUGIN | F9 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 N1 APARTMENT_LIGHTS_PLUGIN | F9 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 N2 APARTMENT_LIGHTS_PLUGIN | F9 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 S1 APARTMENT_LIGHTS_PLUGIN | F9 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 S2 APARTMENT_LIGHTS_PLUGIN | F9 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T SW APARTMENT_LIGHTS_PLUGIN | T SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T NW APARTMENT_LIGHTS_PLUGIN | T NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T SE APARTMENT_LIGHTS_PLUGIN | T SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T NE APARTMENT_LIGHTS_PLUGIN | T NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T N1 APARTMENT_LIGHTS_PLUGIN | T N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T N2 APARTMENT_LIGHTS_PLUGIN | T N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T S1 APARTMENT_LIGHTS_PLUGIN | T S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T S2 APARTMENT_LIGHTS_PLUGIN | T S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
Interior Lighting Total | 2.2679 | 14974.03 | 33959.19 | 296.56 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 10364.00 | AstronomicalClock | - | 83.65 | 83.65 | 162.75 | |
Exterior Lighting Total | 10364.00 | 162.75 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:36
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
CENTRAL BOILER | Boiler:HotWater | 363812.06 | 0.75 | ||
CENTRAL TOWER | EvaporativeFluidCooler:SingleSpeed | 291049.65 |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
HEAT PUMP COOLING MODE AIRLOOP G SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4944.70 | 3594.30 | 1350.41 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4819.86 | 3505.73 | 1314.14 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP OFFICE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6484.99 | 4721.09 | 1763.90 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4053.52 | 2947.75 | 1105.77 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2825.99 | 2004.98 | 821.01 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2811.26 | 1993.91 | 817.35 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3153.41 | 2230.14 | 923.26 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3235.37 | 2292.13 | 943.24 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5631.45 | 4118.89 | 1512.56 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5494.17 | 4018.91 | 1475.26 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5311.55 | 3887.58 | 1423.97 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4678.02 | 3420.19 | 1257.83 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3207.74 | 2296.47 | 911.27 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3196.33 | 2287.88 | 908.45 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3596.21 | 2568.45 | 1027.77 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3622.42 | 2588.24 | 1034.18 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5656.23 | 4141.34 | 1514.89 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5521.67 | 4043.39 | 1478.28 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5071.97 | 3711.05 | 1360.92 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4725.41 | 3459.59 | 1265.82 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3241.26 | 2323.92 | 917.34 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3230.10 | 2315.52 | 914.58 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3628.31 | 2594.88 | 1033.43 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3638.75 | 2602.76 | 1035.99 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5700.68 | 4177.63 | 1523.05 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5565.27 | 4079.01 | 1486.26 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5089.00 | 3726.67 | 1362.33 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4769.53 | 3495.59 | 1273.94 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3282.13 | 2356.35 | 925.78 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3271.14 | 2348.07 | 923.07 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3664.24 | 2623.66 | 1040.59 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3672.38 | 2629.80 | 1042.58 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5775.51 | 4234.89 | 1540.62 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5636.05 | 4135.48 | 1500.57 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5154.81 | 3778.50 | 1376.32 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4838.72 | 3549.95 | 1288.77 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3347.39 | 2406.82 | 940.56 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3336.53 | 2398.65 | 937.88 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3724.95 | 2670.84 | 1054.11 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3732.74 | 2676.72 | 1056.02 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5763.95 | 4228.17 | 1535.78 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5622.84 | 4127.52 | 1495.32 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5142.86 | 3771.43 | 1371.42 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4825.97 | 3542.27 | 1283.70 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3332.42 | 2396.71 | 935.71 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3321.73 | 2388.66 | 933.07 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3712.36 | 2661.02 | 1051.34 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3715.54 | 2664.88 | 1050.67 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5778.07 | 4240.53 | 1537.54 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5636.58 | 4139.60 | 1496.98 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5156.79 | 3783.62 | 1373.16 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4854.16 | 3561.09 | 1293.07 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3352.76 | 2410.75 | 942.02 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3342.47 | 2402.99 | 939.48 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3721.41 | 2668.85 | 1052.55 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3724.14 | 2672.37 | 1051.77 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5811.70 | 4267.40 | 1544.30 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5670.12 | 4166.39 | 1503.73 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5189.65 | 3809.90 | 1379.76 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4888.03 | 3588.11 | 1299.92 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3384.35 | 2435.45 | 948.90 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3374.18 | 2427.78 | 946.39 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3749.74 | 2691.16 | 1058.59 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3756.44 | 2696.21 | 1060.23 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5986.62 | 4401.83 | 1584.80 | 0.74 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5854.40 | 4306.46 | 1547.94 | 0.74 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5321.03 | 3907.51 | 1413.53 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5005.45 | 3677.95 | 1327.50 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3544.48 | 2559.13 | 985.35 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3542.93 | 2555.77 | 987.16 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3884.62 | 2793.86 | 1090.77 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3892.07 | 2799.47 | 1092.59 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 7202.93 | 5313.14 | 1889.79 | 0.74 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6988.79 | 5155.84 | 1832.95 | 0.74 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6515.69 | 4791.43 | 1724.26 | 0.74 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5962.26 | 4396.91 | 1565.34 | 0.74 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4594.55 | 3330.19 | 1264.36 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4592.76 | 3328.85 | 1263.91 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5091.20 | 3704.44 | 1386.76 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5098.39 | 3709.85 | 1388.53 | 0.73 | 0.00 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
None |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
HEAT PUMP HEATING MODE AIRLOOP G SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4944.70 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4819.86 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP OFFICE | Coil:Heating:WaterToAirHeatPump:EquationFit | 6484.99 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4053.52 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2825.99 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2811.26 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3153.41 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3235.37 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5631.45 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5494.17 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5311.55 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4678.02 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3207.74 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3196.33 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3596.21 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3622.42 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5656.23 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5521.67 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5071.97 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4725.41 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3241.26 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3230.10 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3628.31 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3638.75 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5700.68 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5565.27 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5089.00 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4769.53 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3282.13 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3271.14 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3664.24 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3672.38 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5775.51 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5636.05 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5154.81 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4838.72 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3347.39 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3336.53 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3724.95 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3732.74 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5763.95 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5622.84 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5142.86 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4825.97 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3332.42 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3321.73 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3712.36 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3715.54 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5778.07 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5636.58 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5156.79 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4854.16 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3352.76 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3342.47 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3721.41 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3724.14 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5811.70 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5670.12 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5189.65 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4888.03 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3384.35 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3374.18 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3749.74 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3756.44 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5986.62 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5854.40 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5321.03 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5005.45 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3544.48 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3542.93 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3884.62 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3892.07 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 7202.93 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 6988.79 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 6515.69 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5962.26 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4594.55 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4592.76 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 5091.20 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 5098.39 | 0.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW | Coil:Heating:Electric | 1814.94 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW | Coil:Heating:Electric | 1816.25 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE | Coil:Heating:Electric | 2375.90 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE | Coil:Heating:Electric | 1811.69 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 | Coil:Heating:Electric | 1282.95 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 | Coil:Heating:Electric | 1282.88 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 | Coil:Heating:Electric | 1279.12 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 | Coil:Heating:Electric | 1285.25 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW | Coil:Heating:Electric | 1769.67 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW | Coil:Heating:Electric | 1770.54 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE | Coil:Heating:Electric | 1784.02 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE | Coil:Heating:Electric | 1765.38 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 | Coil:Heating:Electric | 1140.24 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 | Coil:Heating:Electric | 1140.15 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 | Coil:Heating:Electric | 1142.10 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 | Coil:Heating:Electric | 1143.42 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW | Coil:Heating:Electric | 1753.45 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW | Coil:Heating:Electric | 1754.10 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE | Coil:Heating:Electric | 1750.98 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE | Coil:Heating:Electric | 1749.20 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 | Coil:Heating:Electric | 1105.96 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 | Coil:Heating:Electric | 1105.87 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 | Coil:Heating:Electric | 1105.89 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 | Coil:Heating:Electric | 1106.06 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW | Coil:Heating:Electric | 1768.71 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW | Coil:Heating:Electric | 1769.66 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE | Coil:Heating:Electric | 1764.45 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE | Coil:Heating:Electric | 1765.11 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 | Coil:Heating:Electric | 1107.04 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 | Coil:Heating:Electric | 1106.96 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 | Coil:Heating:Electric | 1106.41 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 | Coil:Heating:Electric | 1106.36 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW | Coil:Heating:Electric | 1768.36 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW | Coil:Heating:Electric | 1768.46 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE | Coil:Heating:Electric | 1764.22 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE | Coil:Heating:Electric | 1764.28 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 | Coil:Heating:Electric | 1097.31 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 | Coil:Heating:Electric | 1097.23 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 | Coil:Heating:Electric | 1097.45 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 | Coil:Heating:Electric | 1097.38 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW | Coil:Heating:Electric | 1825.51 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW | Coil:Heating:Electric | 1826.44 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE | Coil:Heating:Electric | 1821.69 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE | Coil:Heating:Electric | 1822.62 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 | Coil:Heating:Electric | 1141.72 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 | Coil:Heating:Electric | 1141.65 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 | Coil:Heating:Electric | 1141.01 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 | Coil:Heating:Electric | 1140.95 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW | Coil:Heating:Electric | 1861.44 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW | Coil:Heating:Electric | 1862.16 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE | Coil:Heating:Electric | 1857.98 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE | Coil:Heating:Electric | 1858.69 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 | Coil:Heating:Electric | 1168.49 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 | Coil:Heating:Electric | 1168.43 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 | Coil:Heating:Electric | 1167.96 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 | Coil:Heating:Electric | 1167.90 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW | Coil:Heating:Electric | 1900.21 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW | Coil:Heating:Electric | 1900.58 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE | Coil:Heating:Electric | 1897.08 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE | Coil:Heating:Electric | 1897.46 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 | Coil:Heating:Electric | 1199.32 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 | Coil:Heating:Electric | 1199.26 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 | Coil:Heating:Electric | 1199.11 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 | Coil:Heating:Electric | 1199.05 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW | Coil:Heating:Electric | 2022.47 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW | Coil:Heating:Electric | 2021.10 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE | Coil:Heating:Electric | 2019.65 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE | Coil:Heating:Electric | 2018.28 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 | Coil:Heating:Electric | 1307.00 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 | Coil:Heating:Electric | 1306.95 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 | Coil:Heating:Electric | 1308.28 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 | Coil:Heating:Electric | 1308.23 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW | Coil:Heating:Electric | 2441.16 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW | Coil:Heating:Electric | 2443.61 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE | Coil:Heating:Electric | 2438.78 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE | Coil:Heating:Electric | 2441.23 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 | Coil:Heating:Electric | 1757.79 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 | Coil:Heating:Electric | 1757.74 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 | Coil:Heating:Electric | 1754.39 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 | Coil:Heating:Electric | 1754.35 | 1.00 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
AIRLOOP G SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 383.21 | 1160.84 | 1.00 | General |
AIRLOOP G NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 374.68 | 1160.84 | 1.00 | General |
AIRLOOP OFFICE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.43 | 503.22 | 1160.84 | 1.00 | General |
AIRLOOP G NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 313.86 | 1160.84 | 1.00 | General |
AIRLOOP G N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 206.73 | 1160.84 | 1.00 | General |
AIRLOOP G N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 205.49 | 1160.84 | 1.00 | General |
AIRLOOP G S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.20 | 228.12 | 1160.84 | 1.00 | General |
AIRLOOP G S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.20 | 235.07 | 1160.84 | 1.00 | General |
AIRLOOP F2 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.38 | 443.19 | 1160.84 | 1.00 | General |
AIRLOOP F2 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.37 | 433.07 | 1160.84 | 1.00 | General |
AIRLOOP F2 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.36 | 418.42 | 1160.84 | 1.00 | General |
AIRLOOP F2 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 367.00 | 1160.84 | 1.00 | General |
AIRLOOP F2 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 239.35 | 1160.84 | 1.00 | General |
AIRLOOP F2 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 238.38 | 1160.84 | 1.00 | General |
AIRLOOP F2 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 266.30 | 1160.84 | 1.00 | General |
AIRLOOP F2 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 268.53 | 1160.84 | 1.00 | General |
AIRLOOP F3 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.38 | 445.94 | 1160.84 | 1.00 | General |
AIRLOOP F3 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.38 | 436.05 | 1160.84 | 1.00 | General |
AIRLOOP F3 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.34 | 398.64 | 1160.84 | 1.00 | General |
AIRLOOP F3 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 371.66 | 1160.84 | 1.00 | General |
AIRLOOP F3 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 242.56 | 1160.84 | 1.00 | General |
AIRLOOP F3 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 241.61 | 1160.84 | 1.00 | General |
AIRLOOP F3 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 269.39 | 1160.84 | 1.00 | General |
AIRLOOP F3 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 270.28 | 1160.84 | 1.00 | General |
AIRLOOP F4 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.39 | 450.20 | 1160.84 | 1.00 | General |
AIRLOOP F4 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.38 | 440.23 | 1160.84 | 1.00 | General |
AIRLOOP F4 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.35 | 400.56 | 1160.84 | 1.00 | General |
AIRLOOP F4 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 375.88 | 1160.84 | 1.00 | General |
AIRLOOP F4 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 246.29 | 1160.84 | 1.00 | General |
AIRLOOP F4 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 245.36 | 1160.84 | 1.00 | General |
AIRLOOP F4 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 272.72 | 1160.84 | 1.00 | General |
AIRLOOP F4 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 273.41 | 1160.84 | 1.00 | General |
AIRLOOP M SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.39 | 456.51 | 1160.84 | 1.00 | General |
AIRLOOP M NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.38 | 446.51 | 1160.84 | 1.00 | General |
AIRLOOP M SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.35 | 406.55 | 1160.84 | 1.00 | General |
AIRLOOP M NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 382.16 | 1160.84 | 1.00 | General |
AIRLOOP M N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 252.05 | 1160.84 | 1.00 | General |
AIRLOOP M N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 251.13 | 1160.84 | 1.00 | General |
AIRLOOP M S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 278.10 | 1160.84 | 1.00 | General |
AIRLOOP M S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 278.76 | 1160.84 | 1.00 | General |
AIRLOOP F6 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.39 | 455.86 | 1160.84 | 1.00 | General |
AIRLOOP F6 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.38 | 445.72 | 1160.84 | 1.00 | General |
AIRLOOP F6 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.35 | 405.85 | 1160.84 | 1.00 | General |
AIRLOOP F6 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 381.39 | 1160.84 | 1.00 | General |
AIRLOOP F6 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 250.97 | 1160.84 | 1.00 | General |
AIRLOOP F6 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 250.07 | 1160.84 | 1.00 | General |
AIRLOOP F6 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 276.86 | 1160.84 | 1.00 | General |
AIRLOOP F6 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 277.49 | 1160.84 | 1.00 | General |
AIRLOOP F7 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.39 | 457.35 | 1160.84 | 1.00 | General |
AIRLOOP F7 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.39 | 447.18 | 1160.84 | 1.00 | General |
AIRLOOP F7 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.35 | 407.32 | 1160.84 | 1.00 | General |
AIRLOOP F7 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 382.97 | 1160.84 | 1.00 | General |
AIRLOOP F7 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 252.12 | 1160.84 | 1.00 | General |
AIRLOOP F7 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 251.24 | 1160.84 | 1.00 | General |
AIRLOOP F7 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 277.80 | 1160.84 | 1.00 | General |
AIRLOOP F7 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 278.39 | 1160.84 | 1.00 | General |
AIRLOOP F8 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.40 | 460.47 | 1160.84 | 1.00 | General |
AIRLOOP F8 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.39 | 450.30 | 1160.84 | 1.00 | General |
AIRLOOP F8 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.35 | 410.38 | 1160.84 | 1.00 | General |
AIRLOOP F8 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 386.11 | 1160.84 | 1.00 | General |
AIRLOOP F8 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 254.95 | 1160.84 | 1.00 | General |
AIRLOOP F8 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 254.08 | 1160.84 | 1.00 | General |
AIRLOOP F8 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 280.35 | 1160.84 | 1.00 | General |
AIRLOOP F8 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 280.92 | 1160.84 | 1.00 | General |
AIRLOOP F9 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.41 | 476.07 | 1160.84 | 1.00 | General |
AIRLOOP F9 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.40 | 466.24 | 1160.84 | 1.00 | General |
AIRLOOP F9 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.36 | 421.08 | 1160.84 | 1.00 | General |
AIRLOOP F9 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.34 | 396.36 | 1160.84 | 1.00 | General |
AIRLOOP F9 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 269.42 | 1160.84 | 1.00 | General |
AIRLOOP F9 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 268.55 | 1160.84 | 1.00 | General |
AIRLOOP F9 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 291.96 | 1160.84 | 1.00 | General |
AIRLOOP F9 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 292.60 | 1160.84 | 1.00 | General |
AIRLOOP T SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.50 | 578.50 | 1160.84 | 1.00 | General |
AIRLOOP T NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.48 | 561.28 | 1160.84 | 1.00 | General |
AIRLOOP T SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.45 | 518.60 | 1160.84 | 1.00 | General |
AIRLOOP T NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.41 | 477.45 | 1160.84 | 1.00 | General |
AIRLOOP T N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 352.50 | 1160.84 | 1.00 | General |
AIRLOOP T N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 352.35 | 1160.84 | 1.00 | General |
AIRLOOP T S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.34 | 394.79 | 1160.84 | 1.00 | General |
AIRLOOP T S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.34 | 395.40 | 1160.84 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
SHWSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.0003 | 36.93 | 127739.32 | 0.30 |
PLANT CIRC PUMP | Pump:ConstantSpeed | Intermittent | 224180.02 | 0.0079 | 2527.04 | 319344.75 | 0.90 |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SHWSYS1 WATER HEATER | WaterHeater:Mixed | 2.27 | 175842.64 | 0.80 | 0.00 | 0.00 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:36
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 3375.32 | 4050.38 | 0.275 | 0.330 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:15:00 | 42.44 | 0.00720 |
G NW APARTMENT | 3300.19 | 3960.22 | 0.269 | 0.323 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 41.12 | 0.00720 |
OFFICE | 4432.39 | 5318.87 | 0.361 | 0.433 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:15:00 | 40.94 | 0.00720 |
G NE APARTMENT | 2764.49 | 3317.38 | 0.225 | 0.270 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 39.74 | 0.00720 |
G N1 APARTMENT | 1820.87 | 2185.04 | 0.148 | 0.178 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 39.62 | 0.00720 |
G N2 APARTMENT | 1809.93 | 2171.92 | 0.148 | 0.177 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 39.62 | 0.00720 |
G S1 APARTMENT | 2009.29 | 2411.15 | 0.164 | 0.197 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 43.25 | 0.00720 |
G S2 APARTMENT | 2070.50 | 2484.60 | 0.169 | 0.203 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 43.25 | 0.00720 |
F2 SW APARTMENT | 3903.69 | 4684.43 | 0.318 | 0.382 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 42.20 | 0.00720 |
F2 NW APARTMENT | 3814.50 | 4577.40 | 0.311 | 0.373 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 41.12 | 0.00720 |
F2 SE APARTMENT | 3685.45 | 4422.53 | 0.300 | 0.360 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:30:00 | 41.24 | 0.00720 |
F2 NE APARTMENT | 3232.57 | 3879.09 | 0.263 | 0.316 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 40.19 | 0.00720 |
F2 N1 APARTMENT | 2108.16 | 2529.79 | 0.172 | 0.206 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 40.07 | 0.00720 |
F2 N2 APARTMENT | 2099.65 | 2519.58 | 0.171 | 0.205 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 40.07 | 0.00720 |
F2 S1 APARTMENT | 2345.60 | 2814.71 | 0.191 | 0.229 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 43.25 | 0.00720 |
F2 S2 APARTMENT | 2365.20 | 2838.24 | 0.193 | 0.231 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 43.25 | 0.00720 |
F3 SW APARTMENT | 3927.89 | 4713.47 | 0.320 | 0.384 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 42.20 | 0.00720 |
F3 NW APARTMENT | 3840.74 | 4608.88 | 0.313 | 0.376 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 41.12 | 0.00720 |
F3 SE APARTMENT | 3511.26 | 4213.51 | 0.286 | 0.343 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:30:00 | 41.24 | 0.00720 |
F3 NE APARTMENT | 3273.62 | 3928.35 | 0.267 | 0.320 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 40.19 | 0.00720 |
F3 N1 APARTMENT | 2136.42 | 2563.71 | 0.174 | 0.209 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 40.07 | 0.00720 |
F3 N2 APARTMENT | 2128.10 | 2553.72 | 0.173 | 0.208 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 40.07 | 0.00720 |
F3 S1 APARTMENT | 2372.83 | 2847.39 | 0.193 | 0.232 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 43.25 | 0.00720 |
F3 S2 APARTMENT | 2380.63 | 2856.76 | 0.194 | 0.233 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 43.25 | 0.00720 |
F4 SW APARTMENT | 3965.43 | 4758.52 | 0.323 | 0.388 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 42.20 | 0.00720 |
F4 NW APARTMENT | 3877.61 | 4653.14 | 0.316 | 0.379 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 41.12 | 0.00720 |
F4 SE APARTMENT | 3528.16 | 4233.79 | 0.288 | 0.345 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:30:00 | 41.24 | 0.00720 |
F4 NE APARTMENT | 3310.83 | 3973.00 | 0.270 | 0.324 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 40.19 | 0.00720 |
F4 N1 APARTMENT | 2169.35 | 2603.22 | 0.177 | 0.212 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 40.07 | 0.00720 |
F4 N2 APARTMENT | 2161.15 | 2593.38 | 0.176 | 0.211 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 40.07 | 0.00720 |
F4 S1 APARTMENT | 2402.12 | 2882.54 | 0.196 | 0.235 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 43.25 | 0.00720 |
F4 S2 APARTMENT | 2408.21 | 2889.85 | 0.196 | 0.236 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 43.25 | 0.00720 |
M SW APARTMENT | 4021.02 | 4825.22 | 0.328 | 0.393 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:15:00 | 42.44 | 0.00720 |
M NW APARTMENT | 3932.96 | 4719.55 | 0.321 | 0.385 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 41.42 | 0.00720 |
M SE APARTMENT | 3580.91 | 4297.10 | 0.292 | 0.350 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:30:00 | 41.24 | 0.00720 |
M NE APARTMENT | 3366.11 | 4039.33 | 0.274 | 0.329 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 40.19 | 0.00720 |
M N1 APARTMENT | 2220.05 | 2664.06 | 0.181 | 0.217 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 40.07 | 0.00720 |
M N2 APARTMENT | 2211.94 | 2654.33 | 0.180 | 0.216 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 40.07 | 0.00720 |
M S1 APARTMENT | 2449.53 | 2939.44 | 0.200 | 0.240 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 43.25 | 0.00720 |
M S2 APARTMENT | 2455.36 | 2946.43 | 0.200 | 0.240 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 43.25 | 0.00720 |
F6 SW APARTMENT | 4015.25 | 4818.30 | 0.327 | 0.393 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:15:00 | 42.44 | 0.00720 |
F6 NW APARTMENT | 3925.97 | 4711.17 | 0.320 | 0.384 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 41.42 | 0.00720 |
F6 SE APARTMENT | 3574.80 | 4289.75 | 0.291 | 0.350 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:30:00 | 41.24 | 0.00720 |
F6 NE APARTMENT | 3359.36 | 4031.24 | 0.274 | 0.329 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 40.19 | 0.00720 |
F6 N1 APARTMENT | 2210.57 | 2652.68 | 0.180 | 0.216 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 40.07 | 0.00720 |
F6 N2 APARTMENT | 2202.58 | 2643.09 | 0.180 | 0.215 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 40.07 | 0.00720 |
F6 S1 APARTMENT | 2438.60 | 2926.32 | 0.199 | 0.238 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 43.40 | 0.00720 |
F6 S2 APARTMENT | 2444.16 | 2932.99 | 0.199 | 0.239 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 43.25 | 0.00720 |
F7 SW APARTMENT | 4028.41 | 4834.09 | 0.328 | 0.394 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:15:00 | 42.44 | 0.00720 |
F7 NW APARTMENT | 3938.84 | 4726.61 | 0.321 | 0.385 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 41.42 | 0.00720 |
F7 SE APARTMENT | 3587.76 | 4305.31 | 0.292 | 0.351 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:30:00 | 41.24 | 0.00720 |
F7 NE APARTMENT | 3373.31 | 4047.97 | 0.275 | 0.330 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 40.64 | 0.00720 |
F7 N1 APARTMENT | 2220.66 | 2664.79 | 0.181 | 0.217 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 40.52 | 0.00720 |
F7 N2 APARTMENT | 2212.96 | 2655.55 | 0.180 | 0.216 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 40.52 | 0.00720 |
F7 S1 APARTMENT | 2446.84 | 2936.21 | 0.199 | 0.239 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 43.40 | 0.00720 |
F7 S2 APARTMENT | 2452.07 | 2942.48 | 0.200 | 0.240 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 43.25 | 0.00720 |
F8 SW APARTMENT | 4055.94 | 4867.13 | 0.331 | 0.397 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:15:00 | 42.44 | 0.00720 |
F8 NW APARTMENT | 3966.31 | 4759.57 | 0.323 | 0.388 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 41.42 | 0.00720 |
F8 SE APARTMENT | 3614.68 | 4337.62 | 0.295 | 0.354 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:30:00 | 41.24 | 0.00720 |
F8 NE APARTMENT | 3400.97 | 4081.16 | 0.277 | 0.333 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 40.64 | 0.00720 |
F8 N1 APARTMENT | 2245.59 | 2694.70 | 0.183 | 0.220 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 40.52 | 0.00720 |
F8 N2 APARTMENT | 2237.98 | 2685.57 | 0.182 | 0.219 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 40.52 | 0.00720 |
F8 S1 APARTMENT | 2469.39 | 2963.26 | 0.201 | 0.242 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 43.40 | 0.00720 |
F8 S2 APARTMENT | 2474.39 | 2969.27 | 0.202 | 0.242 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 43.40 | 0.00720 |
F9 SW APARTMENT | 4193.36 | 5032.03 | 0.342 | 0.410 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 42.20 | 0.00720 |
F9 NW APARTMENT | 4106.72 | 4928.06 | 0.335 | 0.402 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 41.42 | 0.00720 |
F9 SE APARTMENT | 3708.93 | 4450.72 | 0.302 | 0.363 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:45:00 | 41.54 | 0.00720 |
F9 NE APARTMENT | 3491.22 | 4189.46 | 0.285 | 0.341 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 40.64 | 0.00720 |
F9 N1 APARTMENT | 2373.05 | 2847.66 | 0.193 | 0.232 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 40.07 | 0.00720 |
F9 N2 APARTMENT | 2365.37 | 2838.44 | 0.193 | 0.231 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 40.52 | 0.00720 |
F9 S1 APARTMENT | 2571.65 | 3085.98 | 0.210 | 0.252 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 43.40 | 0.00720 |
F9 S2 APARTMENT | 2577.22 | 3092.67 | 0.210 | 0.252 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 43.40 | 0.00720 |
T SW APARTMENT | 5095.57 | 6114.69 | 0.415 | 0.498 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:45:00 | 42.86 | 0.00720 |
T NW APARTMENT | 4943.93 | 5932.71 | 0.403 | 0.484 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:15:00 | 42.44 | 0.00720 |
T SE APARTMENT | 4567.98 | 5481.57 | 0.372 | 0.447 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 43.40 | 0.00720 |
T NE APARTMENT | 4205.49 | 5046.58 | 0.343 | 0.411 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 11:15:00 | 40.94 | 0.00720 |
T N1 APARTMENT | 3104.89 | 3725.87 | 0.253 | 0.304 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 43.40 | 0.00720 |
T N2 APARTMENT | 3103.56 | 3724.27 | 0.253 | 0.304 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 43.40 | 0.00720 |
T S1 APARTMENT | 3477.37 | 4172.84 | 0.283 | 0.340 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 43.40 | 0.00720 |
T S2 APARTMENT | 3482.75 | 4179.30 | 0.284 | 0.341 | PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 43.40 | 0.00720 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 1075.54 | 1290.65 | 0.050 | 0.060 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 3.70 | 0.00513 |
G NW APARTMENT | 1076.65 | 1291.98 | 0.050 | 0.060 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 09:15:00 | 3.70 | 0.00513 |
OFFICE | 1334.90 | 1601.88 | 0.062 | 0.074 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 19:00:00 | 3.70 | 0.00513 |
G NE APARTMENT | 1072.79 | 1287.35 | 0.050 | 0.060 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 09:15:00 | 3.70 | 0.00513 |
G N1 APARTMENT | 625.66 | 750.79 | 0.029 | 0.035 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 09:15:00 | 3.70 | 0.00513 |
G N2 APARTMENT | 625.60 | 750.72 | 0.029 | 0.035 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 09:15:00 | 3.70 | 0.00513 |
G S1 APARTMENT | 622.41 | 746.90 | 0.029 | 0.035 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 09:15:00 | 3.70 | 0.00513 |
G S2 APARTMENT | 627.60 | 753.12 | 0.029 | 0.035 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 09:15:00 | 3.70 | 0.00513 |
F2 SW APARTMENT | 1037.27 | 1244.72 | 0.048 | 0.058 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F2 NW APARTMENT | 1038.01 | 1245.61 | 0.048 | 0.058 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F2 SE APARTMENT | 1049.40 | 1259.28 | 0.049 | 0.058 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F2 NE APARTMENT | 1033.64 | 1240.37 | 0.048 | 0.057 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F2 N1 APARTMENT | 504.98 | 605.98 | 0.023 | 0.028 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F2 N2 APARTMENT | 504.91 | 605.89 | 0.023 | 0.028 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F2 S1 APARTMENT | 506.55 | 607.86 | 0.023 | 0.028 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F2 S2 APARTMENT | 507.68 | 609.21 | 0.024 | 0.028 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F3 SW APARTMENT | 1023.56 | 1228.27 | 0.047 | 0.057 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F3 NW APARTMENT | 1024.11 | 1228.93 | 0.047 | 0.057 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F3 SE APARTMENT | 1021.47 | 1225.76 | 0.047 | 0.057 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F3 NE APARTMENT | 1019.96 | 1223.95 | 0.047 | 0.057 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F3 N1 APARTMENT | 475.99 | 571.19 | 0.022 | 0.026 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F3 N2 APARTMENT | 475.92 | 571.10 | 0.022 | 0.026 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F3 S1 APARTMENT | 475.94 | 571.12 | 0.022 | 0.026 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F3 S2 APARTMENT | 476.08 | 571.29 | 0.022 | 0.026 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F4 SW APARTMENT | 1036.46 | 1243.76 | 0.048 | 0.058 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F4 NW APARTMENT | 1037.26 | 1244.71 | 0.048 | 0.058 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F4 SE APARTMENT | 1032.86 | 1239.43 | 0.048 | 0.057 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F4 NE APARTMENT | 1033.41 | 1240.10 | 0.048 | 0.057 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F4 N1 APARTMENT | 476.91 | 572.29 | 0.022 | 0.027 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F4 N2 APARTMENT | 476.84 | 572.21 | 0.022 | 0.027 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F4 S1 APARTMENT | 476.37 | 571.65 | 0.022 | 0.026 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F4 S2 APARTMENT | 476.34 | 571.61 | 0.022 | 0.026 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
M SW APARTMENT | 1036.17 | 1243.40 | 0.048 | 0.058 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
M NW APARTMENT | 1036.25 | 1243.50 | 0.048 | 0.058 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
M SE APARTMENT | 1032.67 | 1239.20 | 0.048 | 0.057 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
M NE APARTMENT | 1032.72 | 1239.27 | 0.048 | 0.057 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
M N1 APARTMENT | 468.68 | 562.42 | 0.022 | 0.026 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
M N2 APARTMENT | 468.62 | 562.34 | 0.022 | 0.026 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
M S1 APARTMENT | 468.80 | 562.56 | 0.022 | 0.026 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
M S2 APARTMENT | 468.74 | 562.49 | 0.022 | 0.026 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F6 SW APARTMENT | 1084.50 | 1301.40 | 0.050 | 0.060 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F6 NW APARTMENT | 1085.28 | 1302.34 | 0.050 | 0.060 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F6 SE APARTMENT | 1081.27 | 1297.52 | 0.050 | 0.060 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F6 NE APARTMENT | 1082.05 | 1298.46 | 0.050 | 0.060 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F6 N1 APARTMENT | 506.24 | 607.49 | 0.023 | 0.028 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F6 N2 APARTMENT | 506.18 | 607.42 | 0.023 | 0.028 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F6 S1 APARTMENT | 505.64 | 606.77 | 0.023 | 0.028 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F6 S2 APARTMENT | 505.59 | 606.70 | 0.023 | 0.028 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F7 SW APARTMENT | 1114.89 | 1337.86 | 0.052 | 0.062 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F7 NW APARTMENT | 1115.49 | 1338.59 | 0.052 | 0.062 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F7 SE APARTMENT | 1111.95 | 1334.35 | 0.052 | 0.062 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F7 NE APARTMENT | 1112.56 | 1335.07 | 0.052 | 0.062 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F7 N1 APARTMENT | 528.88 | 634.66 | 0.024 | 0.029 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F7 N2 APARTMENT | 528.83 | 634.59 | 0.024 | 0.029 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F7 S1 APARTMENT | 528.43 | 634.12 | 0.024 | 0.029 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F7 S2 APARTMENT | 528.38 | 634.06 | 0.024 | 0.029 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F8 SW APARTMENT | 1147.67 | 1377.20 | 0.053 | 0.064 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F8 NW APARTMENT | 1147.99 | 1377.58 | 0.053 | 0.064 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F8 SE APARTMENT | 1145.02 | 1374.03 | 0.053 | 0.064 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F8 NE APARTMENT | 1145.34 | 1374.41 | 0.053 | 0.064 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F8 N1 APARTMENT | 554.95 | 665.94 | 0.026 | 0.031 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F8 N2 APARTMENT | 554.90 | 665.89 | 0.026 | 0.031 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F8 S1 APARTMENT | 554.77 | 665.72 | 0.026 | 0.031 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F8 S2 APARTMENT | 554.72 | 665.67 | 0.026 | 0.031 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F9 SW APARTMENT | 1251.06 | 1501.27 | 0.058 | 0.070 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F9 NW APARTMENT | 1249.90 | 1499.88 | 0.058 | 0.069 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F9 SE APARTMENT | 1248.68 | 1498.41 | 0.058 | 0.069 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F9 NE APARTMENT | 1247.52 | 1497.02 | 0.058 | 0.069 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F9 N1 APARTMENT | 646.01 | 775.21 | 0.030 | 0.036 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F9 N2 APARTMENT | 645.97 | 775.16 | 0.030 | 0.036 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F9 S1 APARTMENT | 647.09 | 776.51 | 0.030 | 0.036 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
F9 S2 APARTMENT | 647.05 | 776.46 | 0.030 | 0.036 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
T SW APARTMENT | 1605.13 | 1926.16 | 0.074 | 0.089 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
T NW APARTMENT | 1607.20 | 1928.64 | 0.074 | 0.089 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
T SE APARTMENT | 1603.12 | 1923.74 | 0.074 | 0.089 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
T NE APARTMENT | 1605.19 | 1926.23 | 0.074 | 0.089 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
T N1 APARTMENT | 1027.22 | 1232.67 | 0.048 | 0.057 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
T N2 APARTMENT | 1027.19 | 1232.62 | 0.048 | 0.057 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
T S1 APARTMENT | 1024.35 | 1229.22 | 0.047 | 0.057 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
T S2 APARTMENT | 1024.31 | 1229.18 | 0.047 | 0.057 | PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | 3.70 | 0.00513 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
AIRLOOP G SW | 0.33 | 0.33 | 0.06 | 0.06 |
AIRLOOP G NW | 0.32 | 0.32 | 0.06 | 0.06 |
AIRLOOP OFFICE | 0.43 | 0.43 | 0.07 | 0.07 |
AIRLOOP G NE | 0.27 | 0.27 | 0.06 | 0.06 |
AIRLOOP G N1 | 0.18 | 0.18 | 0.03 | 0.03 |
AIRLOOP G N2 | 0.18 | 0.18 | 0.03 | 0.03 |
AIRLOOP G S1 | 0.20 | 0.20 | 0.03 | 0.03 |
AIRLOOP G S2 | 0.20 | 0.20 | 0.03 | 0.03 |
AIRLOOP F2 SW | 0.38 | 0.38 | 0.06 | 0.06 |
AIRLOOP F2 NW | 0.37 | 0.37 | 0.06 | 0.06 |
AIRLOOP F2 SE | 0.36 | 0.36 | 0.06 | 0.06 |
AIRLOOP F2 NE | 0.32 | 0.32 | 0.06 | 0.06 |
AIRLOOP F2 N1 | 0.21 | 0.21 | 0.03 | 0.03 |
AIRLOOP F2 N2 | 0.21 | 0.21 | 0.03 | 0.03 |
AIRLOOP F2 S1 | 0.23 | 0.23 | 0.03 | 0.03 |
AIRLOOP F2 S2 | 0.23 | 0.23 | 0.03 | 0.03 |
AIRLOOP F3 SW | 0.38 | 0.38 | 0.06 | 0.06 |
AIRLOOP F3 NW | 0.38 | 0.38 | 0.06 | 0.06 |
AIRLOOP F3 SE | 0.34 | 0.34 | 0.06 | 0.06 |
AIRLOOP F3 NE | 0.32 | 0.32 | 0.06 | 0.06 |
AIRLOOP F3 N1 | 0.21 | 0.21 | 0.03 | 0.03 |
AIRLOOP F3 N2 | 0.21 | 0.21 | 0.03 | 0.03 |
AIRLOOP F3 S1 | 0.23 | 0.23 | 0.03 | 0.03 |
AIRLOOP F3 S2 | 0.23 | 0.23 | 0.03 | 0.03 |
AIRLOOP F4 SW | 0.39 | 0.39 | 0.06 | 0.06 |
AIRLOOP F4 NW | 0.38 | 0.38 | 0.06 | 0.06 |
AIRLOOP F4 SE | 0.35 | 0.35 | 0.06 | 0.06 |
AIRLOOP F4 NE | 0.32 | 0.32 | 0.06 | 0.06 |
AIRLOOP F4 N1 | 0.21 | 0.21 | 0.03 | 0.03 |
AIRLOOP F4 N2 | 0.21 | 0.21 | 0.03 | 0.03 |
AIRLOOP F4 S1 | 0.23 | 0.23 | 0.03 | 0.03 |
AIRLOOP F4 S2 | 0.24 | 0.24 | 0.03 | 0.03 |
AIRLOOP M SW | 0.39 | 0.39 | 0.06 | 0.06 |
AIRLOOP M NW | 0.38 | 0.38 | 0.06 | 0.06 |
AIRLOOP M SE | 0.35 | 0.35 | 0.06 | 0.06 |
AIRLOOP M NE | 0.33 | 0.33 | 0.06 | 0.06 |
AIRLOOP M N1 | 0.22 | 0.22 | 0.03 | 0.03 |
AIRLOOP M N2 | 0.22 | 0.22 | 0.03 | 0.03 |
AIRLOOP M S1 | 0.24 | 0.24 | 0.03 | 0.03 |
AIRLOOP M S2 | 0.24 | 0.24 | 0.03 | 0.03 |
AIRLOOP F6 SW | 0.39 | 0.39 | 0.06 | 0.06 |
AIRLOOP F6 NW | 0.38 | 0.38 | 0.06 | 0.06 |
AIRLOOP F6 SE | 0.35 | 0.35 | 0.06 | 0.06 |
AIRLOOP F6 NE | 0.33 | 0.33 | 0.06 | 0.06 |
AIRLOOP F6 N1 | 0.22 | 0.22 | 0.03 | 0.03 |
AIRLOOP F6 N2 | 0.22 | 0.22 | 0.03 | 0.03 |
AIRLOOP F6 S1 | 0.24 | 0.24 | 0.03 | 0.03 |
AIRLOOP F6 S2 | 0.24 | 0.24 | 0.03 | 0.03 |
AIRLOOP F7 SW | 0.39 | 0.39 | 0.06 | 0.06 |
AIRLOOP F7 NW | 0.39 | 0.39 | 0.06 | 0.06 |
AIRLOOP F7 SE | 0.35 | 0.35 | 0.06 | 0.06 |
AIRLOOP F7 NE | 0.33 | 0.33 | 0.06 | 0.06 |
AIRLOOP F7 N1 | 0.22 | 0.22 | 0.03 | 0.03 |
AIRLOOP F7 N2 | 0.22 | 0.22 | 0.03 | 0.03 |
AIRLOOP F7 S1 | 0.24 | 0.24 | 0.03 | 0.03 |
AIRLOOP F7 S2 | 0.24 | 0.24 | 0.03 | 0.03 |
AIRLOOP F8 SW | 0.40 | 0.40 | 0.06 | 0.06 |
AIRLOOP F8 NW | 0.39 | 0.39 | 0.06 | 0.06 |
AIRLOOP F8 SE | 0.35 | 0.35 | 0.06 | 0.06 |
AIRLOOP F8 NE | 0.33 | 0.33 | 0.06 | 0.06 |
AIRLOOP F8 N1 | 0.22 | 0.22 | 0.03 | 0.03 |
AIRLOOP F8 N2 | 0.22 | 0.22 | 0.03 | 0.03 |
AIRLOOP F8 S1 | 0.24 | 0.24 | 0.03 | 0.03 |
AIRLOOP F8 S2 | 0.24 | 0.24 | 0.03 | 0.03 |
AIRLOOP F9 SW | 0.41 | 0.41 | 0.07 | 0.07 |
AIRLOOP F9 NW | 0.40 | 0.40 | 0.07 | 0.07 |
AIRLOOP F9 SE | 0.36 | 0.36 | 0.07 | 0.07 |
AIRLOOP F9 NE | 0.34 | 0.34 | 0.07 | 0.07 |
AIRLOOP F9 N1 | 0.23 | 0.23 | 0.04 | 0.04 |
AIRLOOP F9 N2 | 0.23 | 0.23 | 0.04 | 0.04 |
AIRLOOP F9 S1 | 0.25 | 0.25 | 0.04 | 0.04 |
AIRLOOP F9 S2 | 0.25 | 0.25 | 0.04 | 0.04 |
AIRLOOP T SW | 0.50 | 0.50 | 0.09 | 0.09 |
AIRLOOP T NW | 0.48 | 0.48 | 0.09 | 0.09 |
AIRLOOP T SE | 0.45 | 0.45 | 0.09 | 0.09 |
AIRLOOP T NE | 0.41 | 0.41 | 0.09 | 0.09 |
AIRLOOP T N1 | 0.30 | 0.30 | 0.06 | 0.06 |
AIRLOOP T N2 | 0.30 | 0.30 | 0.06 | 0.06 |
AIRLOOP T S1 | 0.34 | 0.34 | 0.06 | 0.06 |
AIRLOOP T S2 | 0.34 | 0.34 | 0.06 | 0.06 |
Report: System Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:36
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 3738.50 | 3191.25 | 107.75 |
G NW APARTMENT | 3329.75 | 4230.25 | 110.75 |
OFFICE | 1475.00 | 180.50 | 0.00 |
G NE APARTMENT | 3348.00 | 4167.00 | 116.75 |
G N1 APARTMENT | 3088.00 | 4622.50 | 136.75 |
G N2 APARTMENT | 3090.25 | 4620.75 | 136.25 |
G S1 APARTMENT | 3388.25 | 3389.25 | 122.75 |
G S2 APARTMENT | 3421.25 | 3299.75 | 120.00 |
F2 SW APARTMENT | 4698.25 | 1607.50 | 55.75 |
F2 NW APARTMENT | 3961.25 | 3071.75 | 66.00 |
F2 SE APARTMENT | 4999.75 | 1402.25 | 52.00 |
F2 NE APARTMENT | 3975.25 | 2993.50 | 71.50 |
F2 N1 APARTMENT | 3617.00 | 3293.25 | 85.75 |
F2 N2 APARTMENT | 3617.50 | 3289.50 | 85.75 |
F2 S1 APARTMENT | 4389.25 | 1432.75 | 66.25 |
F2 S2 APARTMENT | 4409.25 | 1402.00 | 66.00 |
F3 SW APARTMENT | 4874.50 | 1342.75 | 57.75 |
F3 NW APARTMENT | 4078.00 | 2819.75 | 66.50 |
F3 SE APARTMENT | 4978.25 | 1352.75 | 59.00 |
F3 NE APARTMENT | 4094.25 | 2770.75 | 69.00 |
F3 N1 APARTMENT | 3748.00 | 2982.00 | 79.75 |
F3 N2 APARTMENT | 3747.75 | 2977.00 | 79.75 |
F3 S1 APARTMENT | 4640.75 | 1049.75 | 67.50 |
F3 S2 APARTMENT | 4643.25 | 1048.00 | 67.25 |
F4 SW APARTMENT | 4894.25 | 1280.00 | 60.25 |
F4 NW APARTMENT | 4086.75 | 2754.50 | 69.25 |
F4 SE APARTMENT | 4963.50 | 1329.75 | 62.75 |
F4 NE APARTMENT | 4105.75 | 2702.00 | 71.50 |
F4 N1 APARTMENT | 3768.50 | 2857.75 | 80.00 |
F4 N2 APARTMENT | 3767.50 | 2859.50 | 80.50 |
F4 S1 APARTMENT | 4675.75 | 952.50 | 68.50 |
F4 S2 APARTMENT | 4677.50 | 955.50 | 69.00 |
M SW APARTMENT | 4908.50 | 1268.25 | 60.00 |
M NW APARTMENT | 4103.50 | 2714.00 | 70.25 |
M SE APARTMENT | 4973.75 | 1329.00 | 65.00 |
M NE APARTMENT | 4133.25 | 2673.75 | 71.75 |
M N1 APARTMENT | 3797.00 | 2803.00 | 79.25 |
M N2 APARTMENT | 3796.00 | 2803.50 | 79.75 |
M S1 APARTMENT | 4703.50 | 924.25 | 68.25 |
M S2 APARTMENT | 4704.25 | 931.25 | 68.25 |
F6 SW APARTMENT | 4773.25 | 1400.25 | 68.25 |
F6 NW APARTMENT | 4012.25 | 2830.75 | 76.50 |
F6 SE APARTMENT | 4833.75 | 1442.00 | 70.00 |
F6 NE APARTMENT | 4031.75 | 2777.50 | 79.50 |
F6 N1 APARTMENT | 3711.25 | 2925.25 | 87.50 |
F6 N2 APARTMENT | 3712.50 | 2930.00 | 87.25 |
F6 S1 APARTMENT | 4564.25 | 1054.50 | 74.25 |
F6 S2 APARTMENT | 4566.00 | 1057.75 | 74.50 |
F7 SW APARTMENT | 4696.50 | 1483.75 | 72.75 |
F7 NW APARTMENT | 3957.25 | 2886.50 | 79.75 |
F7 SE APARTMENT | 4751.25 | 1518.50 | 73.25 |
F7 NE APARTMENT | 3978.50 | 2840.00 | 84.00 |
F7 N1 APARTMENT | 3665.50 | 2999.25 | 91.00 |
F7 N2 APARTMENT | 3665.75 | 2996.50 | 91.25 |
F7 S1 APARTMENT | 4488.75 | 1142.25 | 78.50 |
F7 S2 APARTMENT | 4492.25 | 1145.50 | 78.75 |
F8 SW APARTMENT | 4656.50 | 1557.50 | 74.25 |
F8 NW APARTMENT | 3933.00 | 2932.75 | 81.00 |
F8 SE APARTMENT | 4704.75 | 1599.00 | 75.75 |
F8 NE APARTMENT | 3956.25 | 2879.75 | 85.75 |
F8 N1 APARTMENT | 3647.50 | 3051.25 | 92.25 |
F8 N2 APARTMENT | 3651.00 | 3051.75 | 92.25 |
F8 S1 APARTMENT | 4437.00 | 1218.25 | 79.50 |
F8 S2 APARTMENT | 4437.50 | 1222.75 | 79.50 |
F9 SW APARTMENT | 4648.00 | 1664.50 | 73.75 |
F9 NW APARTMENT | 3973.00 | 2990.00 | 80.00 |
F9 SE APARTMENT | 4692.00 | 1695.00 | 74.00 |
F9 NE APARTMENT | 3992.00 | 2932.00 | 84.50 |
F9 N1 APARTMENT | 3699.50 | 3091.75 | 89.00 |
F9 N2 APARTMENT | 3701.50 | 3087.75 | 88.50 |
F9 S1 APARTMENT | 4434.25 | 1357.50 | 76.00 |
F9 S2 APARTMENT | 4434.75 | 1364.50 | 76.50 |
T SW APARTMENT | 4970.50 | 2330.25 | 87.75 |
T NW APARTMENT | 4252.75 | 3135.25 | 107.00 |
T SE APARTMENT | 5063.75 | 2277.50 | 88.00 |
T NE APARTMENT | 4350.25 | 3069.50 | 120.75 |
T N1 APARTMENT | 4072.00 | 3216.50 | 95.75 |
T N2 APARTMENT | 4074.75 | 3213.50 | 95.75 |
T S1 APARTMENT | 4904.75 | 2112.00 | 93.00 |
T S2 APARTMENT | 4910.00 | 2117.00 | 93.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 5741.00 | 4645.50 | 175.25 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 0.00 | 69.50 | 0.00 | 69.50 |
G NW APARTMENT | 0.00 | 57.75 | 0.00 | 57.75 |
OFFICE | 0.25 | 10.50 | 0.00 | 8.00 |
G NE APARTMENT | 0.00 | 16.25 | 0.00 | 16.25 |
G N1 APARTMENT | 0.75 | 49.75 | 0.75 | 49.75 |
G N2 APARTMENT | 2.00 | 49.00 | 2.00 | 49.00 |
G S1 APARTMENT | 1.00 | 120.25 | 1.00 | 120.25 |
G S2 APARTMENT | 2.00 | 98.75 | 2.00 | 98.75 |
F2 SW APARTMENT | 0.00 | 59.75 | 0.00 | 59.75 |
F2 NW APARTMENT | 0.00 | 37.00 | 0.00 | 37.00 |
F2 SE APARTMENT | 0.00 | 8.00 | 0.00 | 8.00 |
F2 NE APARTMENT | 0.00 | 13.00 | 0.00 | 13.00 |
F2 N1 APARTMENT | 0.50 | 45.50 | 0.50 | 45.50 |
F2 N2 APARTMENT | 1.00 | 45.00 | 1.00 | 45.00 |
F2 S1 APARTMENT | 0.00 | 151.50 | 0.00 | 151.50 |
F2 S2 APARTMENT | 0.00 | 143.50 | 0.00 | 143.50 |
F3 SW APARTMENT | 0.00 | 61.50 | 0.00 | 61.50 |
F3 NW APARTMENT | 0.00 | 42.25 | 0.00 | 42.25 |
F3 SE APARTMENT | 0.00 | 28.25 | 0.00 | 28.25 |
F3 NE APARTMENT | 0.00 | 15.50 | 0.00 | 15.50 |
F3 N1 APARTMENT | 0.50 | 52.75 | 0.50 | 52.75 |
F3 N2 APARTMENT | 1.00 | 53.75 | 1.00 | 53.75 |
F3 S1 APARTMENT | 0.00 | 177.25 | 0.00 | 177.25 |
F3 S2 APARTMENT | 0.00 | 173.25 | 0.00 | 173.25 |
F4 SW APARTMENT | 0.00 | 59.75 | 0.00 | 59.75 |
F4 NW APARTMENT | 0.00 | 46.25 | 0.00 | 46.25 |
F4 SE APARTMENT | 0.00 | 28.50 | 0.00 | 28.50 |
F4 NE APARTMENT | 0.00 | 18.75 | 0.00 | 18.75 |
F4 N1 APARTMENT | 0.25 | 57.00 | 0.25 | 57.00 |
F4 N2 APARTMENT | 0.50 | 56.75 | 0.50 | 56.75 |
F4 S1 APARTMENT | 0.00 | 168.75 | 0.00 | 168.75 |
F4 S2 APARTMENT | 0.00 | 165.00 | 0.00 | 165.00 |
M SW APARTMENT | 0.00 | 56.25 | 0.00 | 56.25 |
M NW APARTMENT | 0.00 | 46.50 | 0.00 | 46.50 |
M SE APARTMENT | 0.00 | 27.00 | 0.00 | 27.00 |
M NE APARTMENT | 0.00 | 19.50 | 0.00 | 19.50 |
M N1 APARTMENT | 0.75 | 58.25 | 0.75 | 58.25 |
M N2 APARTMENT | 0.50 | 57.50 | 0.50 | 57.50 |
M S1 APARTMENT | 0.00 | 151.50 | 0.00 | 151.50 |
M S2 APARTMENT | 0.00 | 148.25 | 0.00 | 148.25 |
F6 SW APARTMENT | 0.00 | 56.50 | 0.00 | 56.50 |
F6 NW APARTMENT | 0.00 | 49.00 | 0.00 | 49.00 |
F6 SE APARTMENT | 0.00 | 26.75 | 0.00 | 26.75 |
F6 NE APARTMENT | 0.00 | 20.25 | 0.00 | 20.25 |
F6 N1 APARTMENT | 0.75 | 60.25 | 0.75 | 60.25 |
F6 N2 APARTMENT | 0.50 | 61.00 | 0.50 | 61.00 |
F6 S1 APARTMENT | 0.00 | 137.50 | 0.00 | 137.50 |
F6 S2 APARTMENT | 0.00 | 136.75 | 0.00 | 136.75 |
F7 SW APARTMENT | 0.00 | 56.50 | 0.00 | 56.50 |
F7 NW APARTMENT | 0.00 | 50.75 | 0.00 | 50.75 |
F7 SE APARTMENT | 0.00 | 24.50 | 0.00 | 24.50 |
F7 NE APARTMENT | 0.00 | 21.25 | 0.00 | 21.25 |
F7 N1 APARTMENT | 0.25 | 59.75 | 0.25 | 59.75 |
F7 N2 APARTMENT | 0.25 | 60.75 | 0.25 | 60.75 |
F7 S1 APARTMENT | 0.00 | 126.25 | 0.00 | 126.25 |
F7 S2 APARTMENT | 0.00 | 126.50 | 0.00 | 126.50 |
F8 SW APARTMENT | 0.00 | 56.00 | 0.00 | 56.00 |
F8 NW APARTMENT | 0.00 | 51.25 | 0.00 | 51.25 |
F8 SE APARTMENT | 0.00 | 24.75 | 0.00 | 24.75 |
F8 NE APARTMENT | 0.00 | 23.00 | 0.00 | 23.00 |
F8 N1 APARTMENT | 0.50 | 61.00 | 0.50 | 61.00 |
F8 N2 APARTMENT | 0.25 | 61.25 | 0.25 | 61.25 |
F8 S1 APARTMENT | 0.00 | 118.25 | 0.00 | 118.25 |
F8 S2 APARTMENT | 0.00 | 117.25 | 0.00 | 117.25 |
F9 SW APARTMENT | 0.00 | 51.50 | 0.00 | 51.50 |
F9 NW APARTMENT | 0.00 | 48.75 | 0.00 | 48.75 |
F9 SE APARTMENT | 0.00 | 21.50 | 0.00 | 21.50 |
F9 NE APARTMENT | 0.00 | 25.00 | 0.00 | 25.00 |
F9 N1 APARTMENT | 0.00 | 57.75 | 0.00 | 57.75 |
F9 N2 APARTMENT | 0.00 | 54.50 | 0.00 | 54.50 |
F9 S1 APARTMENT | 0.00 | 95.50 | 0.00 | 95.50 |
F9 S2 APARTMENT | 0.00 | 94.50 | 0.00 | 94.50 |
T SW APARTMENT | 0.00 | 31.75 | 0.00 | 31.75 |
T NW APARTMENT | 0.00 | 40.25 | 0.00 | 40.25 |
T SE APARTMENT | 0.00 | 5.75 | 0.00 | 5.75 |
T NE APARTMENT | 0.00 | 16.25 | 0.00 | 16.25 |
T N1 APARTMENT | 0.00 | 19.00 | 0.00 | 19.00 |
T N2 APARTMENT | 0.00 | 16.00 | 0.00 | 16.00 |
T S1 APARTMENT | 0.00 | 49.00 | 0.00 | 49.00 |
T S2 APARTMENT | 0.00 | 48.75 | 0.00 | 48.75 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 11.50 | 364.75 | 11.25 | 362.25 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:36
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.119 | 0.000 | 0.296 |
G NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.119 | 0.000 | 0.279 |
OFFICE | 0.94 | 1.00 | 268.96 | 0.522 | 0.135 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.119 | 0.000 | 0.279 |
G N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.072 | 0.000 | 0.268 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.072 | 0.000 | 0.268 |
G S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.072 | 0.000 | 0.293 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.072 | 0.000 | 0.294 |
F2 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.171 | 0.000 | 0.329 |
F2 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.171 | 0.000 | 0.315 |
F2 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.171 | 0.000 | 0.330 |
F2 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.171 | 0.000 | 0.314 |
F2 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.103 | 0.000 | 0.307 |
F2 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.103 | 0.000 | 0.307 |
F2 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.103 | 0.000 | 0.328 |
F2 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.103 | 0.000 | 0.328 |
F3 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.203 | 0.000 | 0.353 |
F3 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.203 | 0.000 | 0.339 |
F3 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.203 | 0.000 | 0.353 |
F3 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.203 | 0.000 | 0.339 |
F3 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.122 | 0.000 | 0.334 |
F3 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.122 | 0.000 | 0.334 |
F3 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.122 | 0.000 | 0.352 |
F3 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.122 | 0.000 | 0.352 |
F4 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.227 | 0.000 | 0.356 |
F4 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.226 | 0.000 | 0.344 |
F4 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.227 | 0.000 | 0.357 |
F4 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.226 | 0.000 | 0.343 |
F4 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.137 | 0.000 | 0.339 |
F4 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.137 | 0.000 | 0.339 |
F4 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.137 | 0.000 | 0.356 |
F4 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.137 | 0.000 | 0.356 |
M SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.246 | 0.000 | 0.369 |
M NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.246 | 0.000 | 0.356 |
M SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.246 | 0.000 | 0.369 |
M NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.246 | 0.000 | 0.355 |
M N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.148 | 0.000 | 0.351 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.148 | 0.000 | 0.351 |
M S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.149 | 0.000 | 0.368 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.149 | 0.000 | 0.368 |
F6 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.263 | 0.000 | 0.379 |
F6 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.263 | 0.000 | 0.365 |
F6 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.263 | 0.000 | 0.380 |
F6 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.263 | 0.000 | 0.365 |
F6 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.159 | 0.000 | 0.361 |
F6 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.159 | 0.000 | 0.361 |
F6 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.159 | 0.000 | 0.379 |
F6 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.159 | 0.000 | 0.379 |
F7 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.278 | 0.000 | 0.388 |
F7 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.278 | 0.000 | 0.373 |
F7 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.278 | 0.000 | 0.388 |
F7 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.278 | 0.000 | 0.373 |
F7 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.168 | 0.000 | 0.369 |
F7 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.168 | 0.000 | 0.369 |
F7 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.168 | 0.000 | 0.388 |
F7 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.168 | 0.000 | 0.388 |
F8 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.291 | 0.000 | 0.398 |
F8 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.291 | 0.000 | 0.382 |
F8 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.291 | 0.000 | 0.398 |
F8 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.291 | 0.000 | 0.382 |
F8 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.176 | 0.000 | 0.378 |
F8 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.176 | 0.000 | 0.378 |
F8 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.176 | 0.000 | 0.397 |
F8 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.176 | 0.000 | 0.397 |
F9 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.304 | 0.000 | 0.407 |
F9 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.304 | 0.000 | 0.391 |
F9 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.304 | 0.000 | 0.407 |
F9 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.304 | 0.000 | 0.390 |
F9 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.183 | 0.000 | 0.386 |
F9 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.183 | 0.000 | 0.386 |
F9 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.183 | 0.000 | 0.406 |
F9 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.183 | 0.000 | 0.406 |
T SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.315 | 0.000 | 0.412 |
T NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.315 | 0.000 | 0.398 |
T SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.315 | 0.000 | 0.412 |
T NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.355 | 0.315 | 0.000 | 0.398 |
T N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.190 | 0.000 | 0.394 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.190 | 0.000 | 0.394 |
T S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.190 | 0.000 | 0.411 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.190 | 0.000 | 0.411 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.96 | 0.507 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.346 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.346 | 0.000 | 0.000 | 0.000 |
F2 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.346 | 0.000 | 0.000 | 0.000 |
F2 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F2 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.346 | 0.000 | 0.000 | 0.000 |
F2 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F2 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F2 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
F2 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F2 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
F3 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.346 | 0.000 | 0.000 | 0.000 |
F3 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F3 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.346 | 0.000 | 0.000 | 0.000 |
F3 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F3 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F3 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
F3 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F3 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
F4 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.346 | 0.000 | 0.000 | 0.000 |
F4 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F4 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.346 | 0.000 | 0.000 | 0.000 |
F4 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F4 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F4 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
F4 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F4 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.346 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.346 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
F6 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.346 | 0.000 | 0.000 | 0.000 |
F6 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F6 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.346 | 0.000 | 0.000 | 0.000 |
F6 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F6 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F6 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
F6 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F6 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
F7 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.346 | 0.000 | 0.000 | 0.000 |
F7 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F7 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.346 | 0.000 | 0.000 | 0.000 |
F7 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F7 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F7 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
F7 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F7 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
F8 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.346 | 0.000 | 0.000 | 0.000 |
F8 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F8 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.346 | 0.000 | 0.000 | 0.000 |
F8 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F8 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F8 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
F8 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.347 | 0.000 | 0.000 | 0.000 |
F8 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.347 | 0.000 | 0.000 | 0.000 |
F9 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.346 | 0.000 | 0.000 | 0.000 |
F9 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F9 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.346 | 0.000 | 0.000 | 0.000 |
F9 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F9 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
F9 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
F9 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.346 | 0.000 | 0.000 | 0.000 |
F9 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.346 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.345 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.345 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:36
Surfaces by ClassTotal | Outdoors | |
Wall | 420 | 140 |
Floor | 90 | 9 |
Roof | 90 | 9 |
Internal Mass | 80 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 140 | 140 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 80 |
Conditioned Zones | 80 |
Unconditioned Zones | 10 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 4156 |
Defaulted Fields | 814 |
Fields with Defaults | 11184 |
Autosized Fields | 1293 |
Autosizable Fields | 1630 |
Autocalculated Fields | 907 |
Autocalculatable Fields | 1710 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2015-09-09 19:11:36
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 3734.52 | 64869.50 | 11-JAN-03:15 | 197190.81 | 07-JUL-18:00 |
Electricity:Building | 1433.88 | 25760.85 | 01-JAN-03:15 | 70162.48 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity | 296.56 | 6715.87 | 01-JAN-00:15 | 14401.37 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 242.55 | 5824.91 | 01-JAN-00:15 | 11484.27 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 39.38 | 663.42 | 01-JAN-00:15 | 2934.49 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 29.88 | 469.18 | 01-JAN-00:15 | 2345.88 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F2 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F2 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F3 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F3 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F4 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F4 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:M SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M CORRIDOR | 32.88 | 1042.61 | 01-JAN-00:15 | 1042.61 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 32.88 | 1042.61 | 01-JAN-00:15 | 1042.61 | 01-JAN-00:15 |
Electricity:Zone:F6 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F6 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F7 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F7 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F8 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F8 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F9 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F9 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:T SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T CORRIDOR | 179.47 | 1701.70 | 01-JAN-00:15 | 10868.20 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 54.01 | 890.97 | 01-JAN-00:15 | 2917.11 | 01-JAN-19:15 |
InteriorEquipment:Electricity | 1137.32 | 19044.98 | 01-JAN-03:15 | 57142.09 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 1137.32 | 19044.98 | 01-JAN-03:15 | 57142.09 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 9.50 | 194.24 | 01-JAN-00:15 | 588.62 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T CORRIDOR | 163.03 | 1180.40 | 01-JAN-00:15 | 10346.90 | 01-JAN-07:15 |
Fans:Electricity | 884.47 | 28046.48 | 05-JAN-22:15 | 28046.48 | 01-JAN-00:15 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Electricity:HVAC | 2014.19 | 28707.72 | 09-JAN-04:15 | 120887.63 | 10-AUG-16:15 |
ElectricityProduced:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityProduced:HVAC | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricityProduced | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 3734.52 | 64869.50 | 11-JAN-03:15 | 197190.81 | 07-JUL-18:00 |
ElectricityPurchased:Plant | 3734.52 | 64869.50 | 11-JAN-03:15 | 197190.81 | 07-JUL-18:00 |
Cogeneration:ElectricityPurchased | 3734.52 | 64869.50 | 11-JAN-03:15 | 197190.81 | 07-JUL-18:00 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 3734.52 | 64869.50 | 11-JAN-03:15 | 197190.81 | 07-JUL-18:00 |
ElectricityNet:Plant | 3734.52 | 64869.50 | 11-JAN-03:15 | 197190.81 | 07-JUL-18:00 |
Cogeneration:ElectricityNet | 3734.52 | 64869.50 | 11-JAN-03:15 | 197190.81 | 07-JUL-18:00 |
ExteriorLights:Electricity | 162.75 | 0.00 | 01-JAN-07:45 | 10364.00 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 162.75 | 0.00 | 01-JAN-07:45 | 10364.00 | 01-JAN-00:15 |
General:Fans:Electricity | 884.47 | 28046.48 | 05-JAN-22:15 | 28046.48 | 01-JAN-00:15 |
Cooling:Electricity | 1085.41 | 0.00 | 01-JAN-01:15 | 91024.32 | 10-AUG-16:00 |
Heating:Electricity | 8.14 | 0.00 | 01-JAN-09:45 | 19770.67 | 07-MAR-03:00 |
Electricity:Plant | 123.70 | 36.93 | 02-JAN-19:30 | 6383.99 | 01-AUG-17:45 |
HeatRejection:Electricity | 44.12 | 0.00 | 01-JAN-06:00 | 3820.03 | 01-AUG-17:45 |
Boiler Parasitic:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Pumps:Electricity | 79.58 | 36.93 | 02-JAN-19:30 | 2563.97 | 01-JAN-00:15 |
WIRED_LTG_ELECTRICITY | 0.44 | 0.00 | 01-JAN-00:15 | 21.60 | 01-JAN-19:30 |
WIRED_INT_EQUIP | 979.40 | 1018.50 | 01-JAN-00:15 | 10185.00 | 01-JAN-07:15 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 863.21 | 2357.00 | 01-JAN-00:15 | 130830.56 | 10-FEB-07:15 |
Gas:Plant | 863.21 | 2357.00 | 01-JAN-00:15 | 130830.56 | 10-FEB-07:15 |
WaterSystems:Gas | 855.99 | 2357.00 | 01-JAN-00:15 | 74550.51 | 24-JAN-08:00 |
Water Heater:WaterSystems:Gas | 855.99 | 2357.00 | 01-JAN-00:15 | 74550.51 | 24-JAN-08:00 |
Heating:Gas | 7.22 | 0.00 | 01-JAN-00:15 | 62875.08 | 07-MAR-05:15 |
Boiler:Heating:Gas | 7.22 | 0.00 | 01-JAN-00:15 | 62875.08 | 07-MAR-05:15 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
PlantLoopCoolingDemand:Facility | 4572.14 | 0.00 | 01-JAN-01:15 | 433226.96 | 10-AUG-16:00 |
PlantLoopCoolingDemand:HVAC | 4572.14 | 0.00 | 01-JAN-01:15 | 433226.96 | 10-AUG-16:00 |
CoolingCoils:PlantLoopCoolingDemand | 4572.14 | 0.00 | 01-JAN-01:15 | 433226.96 | 10-AUG-16:00 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 8943.67 | 0.00 | 04-JAN-04:00 | 0.00 | 16-JUL-18:00 |
Water:Plant | 8943.67 | 0.00 | 04-JAN-04:00 | 0.00 | 16-JUL-18:00 |
WaterSystems:Water | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:Water | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
MainsWater:Facility | 8943.67 | 0.00 | 04-JAN-04:00 | 0.00 | 16-JUL-18:00 |
MainsWater:Plant | 8943.67 | 0.00 | 04-JAN-04:00 | 0.00 | 16-JUL-18:00 |
WaterSystems:MainsWater | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:MainsWater | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
sub cat:WaterSystems:Water | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
sub cat:WaterSystems:MainsWater | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
HeatRejection:Water | 4165.15 | 0.00 | 01-JAN-06:00 | 0.00 | 16-JUL-18:00 |
HeatRejection:MainsWater | 4165.15 | 0.00 | 01-JAN-06:00 | 0.00 | 16-JUL-18:00 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 682.22 | 299.55 | 27-JUL-01:15 | 94108.75 | 10-FEB-07:15 |
PlantLoopHeatingDemand:Plant | 661.61 | 299.55 | 27-JUL-01:15 | 49191.84 | 25-JAN-08:00 |
WaterSystems:PlantLoopHeatingDemand | 661.61 | 299.55 | 27-JUL-01:15 | 49191.84 | 25-JAN-08:00 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 6952.11 | 6624.99 | 16-FEB-02:15 | 611221.54 | 08-JUL-17:15 |
EnergyTransfer:Building | 2699.45 | 4293.81 | 04-MAY-21:15 | 257371.11 | 09-JUL-17:00 |
EnergyTransfer:Zone:G SW APARTMENT | 30.97 | 0.04 | 04-JAN-23:00 | 3877.54 | 29-SEP-14:30 |
Heating:EnergyTransfer | 76.75 | 0.00 | 19-FEB-15:15 | 59879.32 | 07-MAR-03:00 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 1.36 | 0.00 | 01-JAN-02:30 | 1026.24 | 07-MAR-03:00 |
Cooling:EnergyTransfer | 2622.70 | 0.00 | 01-JAN-17:30 | 257371.11 | 09-JUL-17:00 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 29.61 | 0.00 | 01-JAN-00:15 | 3877.54 | 29-SEP-14:30 |
EnergyTransfer:Zone:G NW APARTMENT | 25.01 | 0.11 | 23-MAY-04:45 | 3644.51 | 02-JUL-17:30 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 2.41 | 0.00 | 07-JAN-16:15 | 1016.28 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 22.59 | 0.00 | 01-JAN-00:15 | 3644.51 | 02-JUL-17:30 |
EnergyTransfer:Zone:OFFICE | 42.05 | 0.01 | 13-FEB-05:15 | 5008.99 | 29-SEP-10:30 |
Heating:EnergyTransfer:Zone:OFFICE | 0.62 | 0.00 | 01-JAN-01:00 | 852.70 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:OFFICE | 41.43 | 0.00 | 01-JAN-00:15 | 5008.99 | 29-SEP-10:30 |
EnergyTransfer:Zone:G NE APARTMENT | 24.19 | 0.04 | 22-MAR-00:30 | 2860.52 | 16-JUL-17:45 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 1.98 | 0.00 | 01-JAN-08:00 | 1024.14 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 22.21 | 0.00 | 01-JAN-00:15 | 2860.52 | 16-JUL-17:45 |
EnergyTransfer:Zone:G N1 APARTMENT | 15.66 | 0.06 | 20-APR-23:15 | 1953.85 | 02-JUL-17:30 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 0.93 | 0.00 | 01-JAN-00:15 | 874.77 | 06-FEB-14:00 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 14.74 | 0.00 | 01-JAN-02:00 | 1953.85 | 02-JUL-17:30 |
EnergyTransfer:Zone:G N2 APARTMENT | 15.67 | 0.02 | 22-APR-04:15 | 1941.89 | 02-JUL-17:30 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 0.92 | 0.00 | 01-JAN-00:15 | 874.29 | 06-FEB-14:00 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 14.74 | 0.00 | 01-JAN-02:00 | 1941.89 | 02-JUL-17:30 |
EnergyTransfer:Zone:G S1 APARTMENT | 22.11 | 0.03 | 14-MAR-02:45 | 2401.95 | 01-OCT-11:45 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.27 | 0.00 | 01-JAN-00:15 | 467.80 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 21.85 | 0.00 | 01-JAN-11:30 | 2401.95 | 01-OCT-11:45 |
EnergyTransfer:Zone:G S2 APARTMENT | 22.54 | 0.01 | 17-NOV-05:45 | 2461.93 | 01-OCT-12:00 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.27 | 0.00 | 01-JAN-00:15 | 451.84 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 22.27 | 0.00 | 01-JAN-11:30 | 2461.93 | 01-OCT-12:00 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F2 SW APARTMENT | 42.26 | 0.02 | 04-MAY-23:15 | 4445.53 | 29-SEP-14:30 |
Heating:EnergyTransfer:Zone:F2 SW APARTMENT | 0.74 | 0.00 | 01-JAN-03:15 | 933.66 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT | 41.52 | 0.00 | 01-JAN-00:15 | 4445.53 | 29-SEP-14:30 |
EnergyTransfer:Zone:F2 NW APARTMENT | 32.94 | 0.05 | 18-FEB-23:30 | 4168.11 | 02-JUL-17:30 |
Heating:EnergyTransfer:Zone:F2 NW APARTMENT | 1.84 | 0.00 | 01-JAN-07:15 | 961.02 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT | 31.10 | 0.00 | 01-JAN-00:15 | 4168.11 | 02-JUL-17:30 |
EnergyTransfer:Zone:F2 SE APARTMENT | 44.20 | 0.01 | 28-DEC-01:30 | 4125.89 | 02-SEP-11:00 |
Heating:EnergyTransfer:Zone:F2 SE APARTMENT | 0.52 | 0.00 | 01-JAN-02:15 | 873.58 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT | 43.68 | 0.00 | 01-JAN-00:15 | 4125.89 | 02-SEP-11:00 |
EnergyTransfer:Zone:F2 NE APARTMENT | 32.34 | 0.02 | 14-JAN-03:00 | 3359.63 | 09-JUL-17:00 |
Heating:EnergyTransfer:Zone:F2 NE APARTMENT | 1.41 | 0.00 | 01-JAN-02:00 | 976.17 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT | 30.93 | 0.00 | 01-JAN-00:15 | 3359.63 | 09-JUL-17:00 |
EnergyTransfer:Zone:F2 N1 APARTMENT | 22.00 | 0.05 | 11-MAR-13:15 | 2273.85 | 02-JUL-17:45 |
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT | 0.47 | 0.00 | 01-JAN-00:15 | 759.99 | 06-FEB-14:00 |
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT | 21.53 | 0.00 | 01-JAN-11:30 | 2273.85 | 02-JUL-17:45 |
EnergyTransfer:Zone:F2 N2 APARTMENT | 22.00 | 0.02 | 10-JAN-23:30 | 2263.94 | 02-JUL-17:45 |
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT | 0.47 | 0.00 | 01-JAN-00:15 | 763.61 | 06-FEB-14:00 |
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT | 21.54 | 0.00 | 01-JAN-11:30 | 2263.94 | 02-JUL-17:45 |
EnergyTransfer:Zone:F2 S1 APARTMENT | 32.23 | 0.04 | 23-MAR-21:00 | 2879.36 | 15-OCT-12:15 |
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT | 0.15 | 0.00 | 01-JAN-00:15 | 340.11 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT | 32.08 | 0.00 | 01-JAN-17:30 | 2879.36 | 15-OCT-12:15 |
EnergyTransfer:Zone:F2 S2 APARTMENT | 32.41 | 0.27 | 27-JAN-16:30 | 2894.26 | 15-OCT-12:30 |
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT | 0.15 | 0.00 | 01-JAN-00:15 | 333.88 | 07-MAR-05:00 |
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT | 32.25 | 0.00 | 01-JAN-17:30 | 2894.26 | 15-OCT-12:30 |
EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F3 SW APARTMENT | 43.73 | 0.03 | 11-DEC-07:45 | 4464.20 | 08-OCT-14:30 |
Heating:EnergyTransfer:Zone:F3 SW APARTMENT | 0.64 | 0.00 | 01-JAN-03:00 | 905.30 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT | 43.09 | 0.00 | 01-JAN-00:15 | 4464.20 | 08-OCT-14:30 |
EnergyTransfer:Zone:F3 NW APARTMENT | 34.09 | 0.05 | 22-NOV-22:45 | 4191.76 | 27-JUN-17:30 |
Heating:EnergyTransfer:Zone:F3 NW APARTMENT | 1.65 | 0.00 | 01-JAN-07:15 | 929.70 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT | 32.44 | 0.00 | 01-JAN-00:15 | 4191.76 | 27-JUN-17:30 |
EnergyTransfer:Zone:F3 SE APARTMENT | 43.83 | 0.01 | 03-MAR-05:15 | 3958.99 | 14-OCT-12:45 |
Heating:EnergyTransfer:Zone:F3 SE APARTMENT | 0.46 | 0.00 | 01-JAN-01:00 | 907.01 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT | 43.37 | 0.00 | 01-JAN-00:15 | 3958.99 | 14-OCT-12:45 |
EnergyTransfer:Zone:F3 NE APARTMENT | 33.57 | 0.01 | 07-DEC-02:30 | 3421.21 | 09-JUL-17:00 |
Heating:EnergyTransfer:Zone:F3 NE APARTMENT | 1.25 | 0.00 | 01-JAN-01:00 | 942.85 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT | 32.32 | 0.00 | 01-JAN-00:15 | 3421.21 | 09-JUL-17:00 |
EnergyTransfer:Zone:F3 N1 APARTMENT | 23.36 | 0.31 | 15-FEB-01:45 | 2301.83 | 02-JUL-18:00 |
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT | 0.38 | 0.00 | 01-JAN-00:15 | 745.88 | 06-FEB-14:00 |
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT | 22.98 | 0.00 | 01-JAN-11:30 | 2301.83 | 02-JUL-18:00 |
EnergyTransfer:Zone:F3 N2 APARTMENT | 23.37 | 0.15 | 08-DEC-01:15 | 2292.16 | 02-JUL-18:15 |
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT | 0.38 | 0.00 | 01-JAN-00:15 | 752.06 | 06-FEB-14:00 |
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT | 22.99 | 0.00 | 01-JAN-11:30 | 2292.16 | 02-JUL-18:15 |
EnergyTransfer:Zone:F3 S1 APARTMENT | 34.16 | 0.18 | 21-NOV-09:00 | 2962.46 | 21-NOV-13:00 |
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT | 0.13 | 0.00 | 01-JAN-00:15 | 245.09 | 07-MAR-05:00 |
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT | 34.02 | 0.00 | 01-JAN-17:30 | 2962.46 | 21-NOV-13:00 |
EnergyTransfer:Zone:F3 S2 APARTMENT | 34.20 | 1.14 | 18-OCT-06:00 | 2971.00 | 21-NOV-13:00 |
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT | 0.14 | 0.00 | 01-JAN-00:15 | 244.41 | 07-MAR-05:00 |
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT | 34.06 | 0.00 | 01-JAN-17:30 | 2971.00 | 21-NOV-13:00 |
EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F4 SW APARTMENT | 44.16 | 0.02 | 01-JAN-03:00 | 4496.24 | 29-SEP-14:30 |
Heating:EnergyTransfer:Zone:F4 SW APARTMENT | 0.64 | 0.00 | 01-JAN-03:15 | 925.63 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT | 43.52 | 0.00 | 01-JAN-00:15 | 4496.24 | 29-SEP-14:30 |
EnergyTransfer:Zone:F4 NW APARTMENT | 34.54 | 0.15 | 10-FEB-24:00 | 4234.18 | 27-JUN-17:30 |
Heating:EnergyTransfer:Zone:F4 NW APARTMENT | 1.65 | 0.00 | 01-JAN-07:15 | 984.20 | 25-JAN-10:45 |
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT | 32.89 | 0.00 | 01-JAN-00:15 | 4234.18 | 27-JUN-17:30 |
EnergyTransfer:Zone:F4 SE APARTMENT | 44.03 | 0.00 | 30-JAN-21:15 | 3965.40 | 08-OCT-13:45 |
Heating:EnergyTransfer:Zone:F4 SE APARTMENT | 0.47 | 0.00 | 01-JAN-01:00 | 937.92 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT | 43.56 | 0.00 | 01-JAN-00:15 | 3965.40 | 08-OCT-13:45 |
EnergyTransfer:Zone:F4 NE APARTMENT | 34.04 | 0.02 | 25-DEC-20:45 | 3475.41 | 09-JUL-17:00 |
Heating:EnergyTransfer:Zone:F4 NE APARTMENT | 1.25 | 0.00 | 01-JAN-01:00 | 961.99 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT | 32.79 | 0.00 | 01-JAN-00:15 | 3475.41 | 09-JUL-17:00 |
EnergyTransfer:Zone:F4 N1 APARTMENT | 23.85 | 0.15 | 28-DEC-16:30 | 2340.21 | 02-JUL-18:30 |
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT | 0.37 | 0.00 | 01-JAN-00:15 | 789.53 | 25-JAN-10:45 |
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT | 23.49 | 0.00 | 01-JAN-11:30 | 2340.21 | 02-JUL-18:30 |
EnergyTransfer:Zone:F4 N2 APARTMENT | 23.86 | 0.02 | 28-DEC-16:30 | 2330.92 | 02-JUL-18:30 |
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT | 0.36 | 0.00 | 01-JAN-00:15 | 799.15 | 25-JAN-10:45 |
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT | 23.49 | 0.00 | 01-JAN-11:30 | 2330.92 | 02-JUL-18:30 |
EnergyTransfer:Zone:F4 S1 APARTMENT | 34.73 | 0.01 | 14-SEP-05:45 | 2992.96 | 21-NOV-13:00 |
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT | 0.14 | 0.00 | 01-JAN-00:15 | 223.51 | 04-MAY-16:00 |
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT | 34.59 | 0.00 | 01-JAN-17:30 | 2992.96 | 21-NOV-13:00 |
EnergyTransfer:Zone:F4 S2 APARTMENT | 34.74 | 0.03 | 02-APR-01:30 | 2999.72 | 21-NOV-13:00 |
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT | 0.14 | 0.00 | 01-JAN-00:15 | 295.30 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT | 34.60 | 0.00 | 01-JAN-17:30 | 2999.72 | 21-NOV-13:00 |
EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M SW APARTMENT | 44.74 | 0.00 | 31-JAN-20:45 | 4554.73 | 29-SEP-14:30 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.68 | 0.00 | 01-JAN-03:15 | 945.03 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 44.06 | 0.00 | 01-JAN-00:15 | 4554.73 | 29-SEP-14:30 |
EnergyTransfer:Zone:M NW APARTMENT | 35.26 | 0.04 | 11-APR-08:00 | 4287.79 | 27-JUN-17:30 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 1.71 | 0.00 | 01-JAN-07:30 | 1074.92 | 25-JAN-10:45 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 33.56 | 0.00 | 01-JAN-00:15 | 4287.79 | 27-JUN-17:30 |
EnergyTransfer:Zone:M SE APARTMENT | 44.57 | 0.02 | 17-FEB-06:00 | 4018.86 | 02-SEP-10:15 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.50 | 0.00 | 01-JAN-01:00 | 959.86 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 44.07 | 0.00 | 01-JAN-00:15 | 4018.86 | 02-SEP-10:15 |
EnergyTransfer:Zone:M NE APARTMENT | 34.75 | 0.00 | 08-DEC-05:45 | 3546.46 | 09-JUL-17:00 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 1.30 | 0.00 | 01-JAN-01:00 | 980.95 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 33.46 | 0.00 | 01-JAN-00:15 | 3546.46 | 09-JUL-17:00 |
EnergyTransfer:Zone:M N1 APARTMENT | 24.53 | 0.18 | 07-DEC-23:45 | 2402.56 | 02-JUL-18:45 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.38 | 0.00 | 01-JAN-00:15 | 858.39 | 25-JAN-10:45 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 24.14 | 0.00 | 01-JAN-11:30 | 2402.56 | 02-JUL-18:45 |
EnergyTransfer:Zone:M N2 APARTMENT | 24.53 | 0.04 | 21-DEC-12:30 | 2393.38 | 02-JUL-18:45 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.38 | 0.00 | 01-JAN-00:15 | 864.97 | 25-JAN-10:45 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 24.15 | 0.00 | 01-JAN-11:30 | 2393.38 | 02-JUL-18:45 |
EnergyTransfer:Zone:M S1 APARTMENT | 35.34 | 0.01 | 12-JAN-11:00 | 3028.73 | 21-NOV-13:30 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.15 | 0.00 | 01-JAN-00:15 | 237.76 | 04-MAY-16:00 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 35.20 | 0.00 | 01-JAN-17:30 | 3028.73 | 21-NOV-13:30 |
EnergyTransfer:Zone:M S2 APARTMENT | 35.35 | 0.09 | 09-JAN-10:30 | 3033.10 | 21-NOV-13:30 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.15 | 0.00 | 01-JAN-00:15 | 238.22 | 04-MAY-16:00 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 35.20 | 0.00 | 01-JAN-17:30 | 3033.10 | 21-NOV-13:30 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F6 SW APARTMENT | 43.94 | 0.00 | 23-DEC-01:30 | 4542.47 | 29-SEP-14:30 |
Heating:EnergyTransfer:Zone:F6 SW APARTMENT | 0.78 | 0.00 | 01-JAN-03:15 | 1009.74 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT | 43.16 | 0.00 | 01-JAN-00:15 | 4542.47 | 29-SEP-14:30 |
EnergyTransfer:Zone:F6 NW APARTMENT | 34.90 | 0.02 | 06-DEC-01:15 | 4274.26 | 17-JUN-16:30 |
Heating:EnergyTransfer:Zone:F6 NW APARTMENT | 1.89 | 0.00 | 01-JAN-07:45 | 1223.21 | 25-JAN-10:45 |
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT | 33.01 | 0.00 | 01-JAN-00:15 | 4274.26 | 17-JUN-16:30 |
EnergyTransfer:Zone:F6 SE APARTMENT | 43.73 | 0.00 | 05-FEB-00:45 | 4004.87 | 02-SEP-10:15 |
Heating:EnergyTransfer:Zone:F6 SE APARTMENT | 0.58 | 0.00 | 01-JAN-01:00 | 1021.95 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT | 43.15 | 0.00 | 01-JAN-00:15 | 4004.87 | 02-SEP-10:15 |
EnergyTransfer:Zone:F6 NE APARTMENT | 34.34 | 0.04 | 24-JAN-10:15 | 3549.29 | 09-JUL-17:00 |
Heating:EnergyTransfer:Zone:F6 NE APARTMENT | 1.46 | 0.00 | 01-JAN-01:00 | 1082.02 | 06-FEB-13:45 |
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT | 32.88 | 0.00 | 01-JAN-00:15 | 3549.29 | 09-JUL-17:00 |
EnergyTransfer:Zone:F6 N1 APARTMENT | 23.98 | 0.01 | 04-MAR-11:30 | 2391.33 | 02-JUL-19:00 |
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT | 0.43 | 0.00 | 01-JAN-00:15 | 997.13 | 25-JAN-10:45 |
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT | 23.56 | 0.00 | 01-JAN-11:30 | 2391.33 | 02-JUL-19:00 |
EnergyTransfer:Zone:F6 N2 APARTMENT | 23.99 | 0.01 | 22-JAN-12:00 | 2382.42 | 02-JUL-19:00 |
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT | 0.43 | 0.00 | 01-JAN-00:15 | 999.13 | 25-JAN-10:45 |
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT | 23.56 | 0.00 | 01-JAN-11:30 | 2382.42 | 02-JUL-19:00 |
EnergyTransfer:Zone:F6 S1 APARTMENT | 34.44 | 1.29 | 05-APR-01:00 | 2984.67 | 21-NOV-13:30 |
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT | 0.16 | 0.00 | 01-JAN-00:15 | 269.53 | 07-MAR-05:00 |
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT | 34.28 | 0.00 | 01-JAN-17:30 | 2984.67 | 21-NOV-13:30 |
EnergyTransfer:Zone:F6 S2 APARTMENT | 34.44 | 0.67 | 14-SEP-06:15 | 2989.07 | 21-NOV-13:30 |
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT | 0.16 | 0.00 | 01-JAN-00:15 | 272.55 | 07-MAR-05:00 |
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT | 34.28 | 0.00 | 01-JAN-17:30 | 2989.07 | 21-NOV-13:30 |
EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F7 SW APARTMENT | 43.62 | 0.00 | 24-NOV-05:15 | 4551.78 | 29-SEP-14:30 |
Heating:EnergyTransfer:Zone:F7 SW APARTMENT | 0.86 | 0.00 | 01-JAN-03:15 | 1057.22 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT | 42.76 | 0.00 | 01-JAN-00:15 | 4551.78 | 29-SEP-14:30 |
EnergyTransfer:Zone:F7 NW APARTMENT | 34.91 | 0.21 | 09-NOV-06:15 | 4290.85 | 17-JUN-16:30 |
Heating:EnergyTransfer:Zone:F7 NW APARTMENT | 2.05 | 0.00 | 01-JAN-08:30 | 1258.91 | 06-FEB-13:45 |
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT | 32.86 | 0.00 | 01-JAN-00:15 | 4290.85 | 17-JUN-16:30 |
EnergyTransfer:Zone:F7 SE APARTMENT | 43.40 | 0.03 | 21-DEC-07:00 | 4012.62 | 02-SEP-10:15 |
Heating:EnergyTransfer:Zone:F7 SE APARTMENT | 0.65 | 0.00 | 01-JAN-01:00 | 1068.56 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT | 42.74 | 0.00 | 01-JAN-00:15 | 4012.62 | 02-SEP-10:15 |
EnergyTransfer:Zone:F7 NE APARTMENT | 34.33 | 0.03 | 11-MAR-03:45 | 3580.40 | 09-JUL-17:00 |
Heating:EnergyTransfer:Zone:F7 NE APARTMENT | 1.61 | 0.00 | 01-JAN-02:15 | 1249.25 | 06-FEB-13:45 |
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT | 32.73 | 0.00 | 01-JAN-00:15 | 3580.40 | 09-JUL-17:00 |
EnergyTransfer:Zone:F7 N1 APARTMENT | 23.85 | 0.03 | 01-APR-22:15 | 2411.56 | 03-JUL-18:00 |
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT | 0.48 | 0.00 | 01-JAN-00:15 | 1063.27 | 06-FEB-13:45 |
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT | 23.37 | 0.00 | 01-JAN-11:30 | 2411.56 | 03-JUL-18:00 |
EnergyTransfer:Zone:F7 N2 APARTMENT | 23.86 | 0.00 | 08-DEC-10:15 | 2402.63 | 03-JUL-18:00 |
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT | 0.48 | 0.00 | 01-JAN-00:15 | 1068.13 | 06-FEB-13:45 |
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT | 23.38 | 0.00 | 01-JAN-11:30 | 2402.63 | 03-JUL-18:00 |
EnergyTransfer:Zone:F7 S1 APARTMENT | 34.04 | 0.23 | 02-APR-02:30 | 2960.86 | 21-NOV-13:30 |
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT | 0.18 | 0.00 | 01-JAN-00:15 | 322.41 | 07-MAR-05:00 |
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT | 33.86 | 0.00 | 01-JAN-11:30 | 2960.86 | 21-NOV-13:30 |
EnergyTransfer:Zone:F7 S2 APARTMENT | 34.04 | 0.05 | 02-APR-02:45 | 2965.30 | 21-NOV-13:30 |
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT | 0.18 | 0.00 | 01-JAN-00:15 | 324.68 | 07-MAR-05:00 |
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT | 33.87 | 0.00 | 01-JAN-11:30 | 2965.30 | 21-NOV-13:30 |
EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F8 SW APARTMENT | 43.57 | 0.09 | 06-DEC-01:45 | 4576.88 | 29-SEP-14:30 |
Heating:EnergyTransfer:Zone:F8 SW APARTMENT | 0.95 | 0.00 | 01-JAN-03:30 | 1107.87 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT | 42.62 | 0.00 | 01-JAN-00:15 | 4576.88 | 29-SEP-14:30 |
EnergyTransfer:Zone:F8 NW APARTMENT | 35.17 | 0.27 | 20-JAN-04:15 | 4320.58 | 17-JUN-16:30 |
Heating:EnergyTransfer:Zone:F8 NW APARTMENT | 2.21 | 0.00 | 01-JAN-08:45 | 1414.09 | 06-FEB-13:45 |
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT | 32.96 | 0.00 | 01-JAN-00:15 | 4320.58 | 17-JUN-16:30 |
EnergyTransfer:Zone:F8 SE APARTMENT | 43.32 | 0.02 | 24-NOV-01:00 | 4036.02 | 02-SEP-10:15 |
Heating:EnergyTransfer:Zone:F8 SE APARTMENT | 0.73 | 0.00 | 01-JAN-01:00 | 1118.73 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT | 42.60 | 0.00 | 01-JAN-00:15 | 4036.02 | 02-SEP-10:15 |
EnergyTransfer:Zone:F8 NE APARTMENT | 34.58 | 0.02 | 30-OCT-04:45 | 3617.80 | 09-JUL-17:00 |
Heating:EnergyTransfer:Zone:F8 NE APARTMENT | 1.76 | 0.00 | 01-JAN-02:30 | 1396.48 | 06-FEB-13:45 |
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT | 32.82 | 0.00 | 01-JAN-00:15 | 3617.80 | 09-JUL-17:00 |
EnergyTransfer:Zone:F8 N1 APARTMENT | 23.97 | 0.01 | 06-MAY-09:45 | 2436.17 | 03-JUL-18:00 |
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT | 0.54 | 0.00 | 01-JAN-00:15 | 1211.42 | 06-FEB-13:45 |
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT | 23.43 | 0.00 | 01-JAN-11:00 | 2436.17 | 03-JUL-18:00 |
EnergyTransfer:Zone:F8 N2 APARTMENT | 23.98 | 0.06 | 09-JAN-24:00 | 2427.34 | 03-JUL-18:00 |
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT | 0.54 | 0.00 | 01-JAN-00:15 | 1215.30 | 06-FEB-13:45 |
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT | 23.44 | 0.00 | 01-JAN-11:30 | 2427.34 | 03-JUL-18:00 |
EnergyTransfer:Zone:F8 S1 APARTMENT | 33.90 | 0.04 | 21-OCT-08:30 | 2965.26 | 27-FEB-13:00 |
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT | 0.19 | 0.00 | 01-JAN-00:15 | 380.59 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT | 33.71 | 0.00 | 01-JAN-11:30 | 2965.26 | 27-FEB-13:00 |
EnergyTransfer:Zone:F8 S2 APARTMENT | 33.91 | 0.19 | 16-FEB-24:00 | 2970.94 | 27-FEB-13:00 |
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT | 0.20 | 0.00 | 01-JAN-00:15 | 382.93 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT | 33.71 | 0.00 | 01-JAN-11:30 | 2970.94 | 27-FEB-13:00 |
EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F9 SW APARTMENT | 44.54 | 0.02 | 21-JAN-04:00 | 4716.30 | 29-SEP-14:30 |
Heating:EnergyTransfer:Zone:F9 SW APARTMENT | 1.15 | 0.00 | 01-JAN-04:00 | 1228.47 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT | 43.39 | 0.00 | 01-JAN-00:15 | 4716.30 | 29-SEP-14:30 |
EnergyTransfer:Zone:F9 NW APARTMENT | 36.56 | 0.31 | 19-FEB-12:00 | 4473.38 | 17-JUN-16:45 |
Heating:EnergyTransfer:Zone:F9 NW APARTMENT | 2.53 | 0.00 | 05-JAN-06:30 | 1585.13 | 06-FEB-13:45 |
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT | 34.02 | 0.00 | 01-JAN-00:15 | 4473.38 | 17-JUN-16:45 |
EnergyTransfer:Zone:F9 SE APARTMENT | 44.23 | 0.00 | 24-JAN-20:45 | 4134.32 | 02-SEP-10:15 |
Heating:EnergyTransfer:Zone:F9 SE APARTMENT | 0.89 | 0.00 | 01-JAN-01:00 | 1242.57 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT | 43.34 | 0.00 | 01-JAN-00:15 | 4134.32 | 02-SEP-10:15 |
EnergyTransfer:Zone:F9 NE APARTMENT | 35.86 | 0.00 | 07-DEC-10:00 | 3729.20 | 09-JUL-17:00 |
Heating:EnergyTransfer:Zone:F9 NE APARTMENT | 2.02 | 0.00 | 01-JAN-03:00 | 1559.04 | 06-FEB-13:45 |
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT | 33.84 | 0.00 | 01-JAN-00:15 | 3729.20 | 09-JUL-17:00 |
EnergyTransfer:Zone:F9 N1 APARTMENT | 24.98 | 0.03 | 27-OCT-19:30 | 2567.17 | 03-JUL-18:00 |
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT | 0.67 | 0.00 | 01-JAN-00:15 | 1387.15 | 06-FEB-13:45 |
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT | 24.30 | 0.00 | 01-JAN-10:45 | 2567.17 | 03-JUL-18:00 |
EnergyTransfer:Zone:F9 N2 APARTMENT | 24.99 | 0.01 | 05-NOV-02:00 | 2565.76 | 03-JUL-18:00 |
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT | 0.68 | 0.00 | 01-JAN-00:15 | 1389.59 | 06-FEB-13:45 |
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT | 24.32 | 0.00 | 01-JAN-11:00 | 2565.76 | 03-JUL-18:00 |
EnergyTransfer:Zone:F9 S1 APARTMENT | 34.56 | 0.17 | 09-FEB-07:00 | 3055.35 | 27-FEB-13:15 |
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT | 0.24 | 0.00 | 01-JAN-00:15 | 504.06 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT | 34.32 | 0.00 | 01-JAN-11:30 | 3055.35 | 27-FEB-13:15 |
EnergyTransfer:Zone:F9 S2 APARTMENT | 34.56 | 0.16 | 03-APR-22:00 | 3061.82 | 27-FEB-13:15 |
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT | 0.24 | 0.00 | 01-JAN-00:15 | 505.76 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT | 34.33 | 0.00 | 01-JAN-11:30 | 3061.82 | 27-FEB-13:15 |
EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:T SW APARTMENT | 50.17 | 0.01 | 18-FEB-23:45 | 5742.52 | 29-SEP-14:30 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 2.97 | 0.00 | 01-JAN-09:15 | 1644.73 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 47.19 | 0.00 | 01-JAN-00:15 | 5742.52 | 29-SEP-14:30 |
EnergyTransfer:Zone:T NW APARTMENT | 42.40 | 0.24 | 11-MAR-23:00 | 5404.48 | 17-JUN-16:30 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 4.46 | 0.00 | 07-JAN-14:15 | 1853.56 | 11-JAN-08:45 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 37.94 | 0.00 | 01-JAN-00:15 | 5404.48 | 17-JUN-16:30 |
EnergyTransfer:Zone:T SE APARTMENT | 49.48 | 0.33 | 28-FEB-03:30 | 5099.59 | 29-SEP-14:30 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 2.59 | 0.00 | 01-JAN-08:15 | 1650.25 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 46.89 | 0.00 | 01-JAN-00:15 | 5099.59 | 29-SEP-14:30 |
EnergyTransfer:Zone:T NE APARTMENT | 41.18 | 0.24 | 28-MAR-08:15 | 4478.03 | 09-JUL-17:00 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 3.78 | 0.00 | 01-JAN-08:30 | 1697.18 | 07-FEB-06:00 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 37.40 | 0.00 | 01-JAN-00:15 | 4478.03 | 09-JUL-17:00 |
EnergyTransfer:Zone:T N1 APARTMENT | 29.55 | 0.03 | 30-OCT-04:00 | 3376.49 | 02-JUL-17:30 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 1.73 | 0.00 | 01-JAN-01:00 | 1484.78 | 06-FEB-13:45 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 27.83 | 0.00 | 01-JAN-00:15 | 3376.49 | 02-JUL-17:30 |
EnergyTransfer:Zone:T N2 APARTMENT | 29.57 | 0.00 | 27-NOV-03:30 | 3359.64 | 02-JUL-17:30 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 1.73 | 0.00 | 01-JAN-01:00 | 1480.47 | 06-FEB-13:45 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 27.84 | 0.00 | 01-JAN-00:15 | 3359.64 | 02-JUL-17:30 |
EnergyTransfer:Zone:T S1 APARTMENT | 38.33 | 0.01 | 10-MAR-05:30 | 4036.36 | 08-OCT-13:30 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 0.89 | 0.00 | 01-JAN-01:00 | 904.07 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 37.44 | 0.00 | 01-JAN-00:15 | 4036.36 | 08-OCT-13:30 |
EnergyTransfer:Zone:T S2 APARTMENT | 38.36 | 0.06 | 29-JAN-10:30 | 4042.20 | 08-OCT-13:30 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 0.90 | 0.00 | 01-JAN-02:30 | 905.03 | 07-MAR-03:00 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 37.46 | 0.00 | 01-JAN-00:15 | 4042.20 | 08-OCT-13:30 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Plant | 666.99 | 299.55 | 27-JUL-01:15 | 91636.93 | 10-FEB-07:15 |
WaterSystems:EnergyTransfer | 661.60 | 299.55 | 27-JUL-01:15 | 49186.81 | 25-JAN-08:00 |
sub cat:WaterSystems:EnergyTransfer | 661.60 | 299.55 | 27-JUL-01:15 | 49186.81 | 25-JAN-08:00 |
EnergyTransfer:HVAC | 3585.67 | 0.00 | 02-JAN-19:30 | 342248.30 | 10-AUG-16:00 |
CoolingCoils:EnergyTransfer | 3558.80 | 0.00 | 01-JAN-01:15 | 342248.30 | 10-AUG-16:00 |
HeatingCoils:EnergyTransfer | 26.86 | 0.00 | 01-JAN-09:45 | 68976.97 | 07-MAR-03:00 |
PlantLoopHeatingDemand:HVAC | 20.61 | 0.00 | 01-JAN-09:45 | 52336.76 | 07-MAR-03:00 |
HeatingCoils:PlantLoopHeatingDemand | 20.61 | 0.00 | 01-JAN-09:45 | 52336.76 | 07-MAR-03:00 |
Boilers:EnergyTransfer | 5.39 | 0.00 | 01-JAN-00:15 | 47156.31 | 07-MAR-05:15 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:36
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 1.363 | -29.612 | 0.000 | 0.000 | 3.627 | 1.087 | 12.213 | 32.534 | 0.000 | 1.547 | 0.001 | 0.000 | -6.036 | 0.000 | -4.483 | -12.238 |
G NW APARTMENT | 2.414 | -22.593 | 0.000 | 0.000 | 3.671 | 1.087 | 12.213 | 19.880 | 0.000 | 1.546 | 0.000 | 0.000 | -6.083 | 0.000 | -3.754 | -8.379 |
OFFICE | 0.621 | -41.430 | 0.000 | 0.000 | 0.504 | 29.882 | 9.495 | 32.097 | 0.000 | 1.433 | 0.000 | 0.000 | -6.046 | 0.000 | -1.191 | -25.365 |
G NE APARTMENT | 1.976 | -22.211 | 0.000 | 0.000 | 3.681 | 1.087 | 12.213 | 19.423 | 0.000 | 1.547 | 0.000 | 0.000 | -5.615 | 0.000 | -3.772 | -8.328 |
G N1 APARTMENT | 0.926 | -14.738 | 0.000 | 0.000 | 3.688 | 1.087 | 12.213 | 7.984 | 0.000 | 0.978 | 0.000 | 0.000 | -3.649 | 0.000 | -2.991 | -5.498 |
G N2 APARTMENT | 0.924 | -14.745 | 0.000 | 0.000 | 3.688 | 1.087 | 12.213 | 7.983 | 0.000 | 0.978 | 0.000 | 0.000 | -3.646 | 0.000 | -2.992 | -5.490 |
G S1 APARTMENT | 0.265 | -21.846 | 0.000 | 0.000 | 3.624 | 1.087 | 12.213 | 20.822 | 0.000 | 0.979 | 0.000 | 0.000 | -3.631 | 0.000 | -3.904 | -9.608 |
G S2 APARTMENT | 0.271 | -22.272 | 0.000 | 0.000 | 3.620 | 1.087 | 12.213 | 20.805 | 0.000 | 0.979 | 0.000 | 0.000 | -3.645 | 0.000 | -3.938 | -9.120 |
F2 SW APARTMENT | 0.738 | -41.525 | 0.000 | 0.000 | 3.566 | 1.087 | 12.213 | 31.618 | 0.000 | 2.183 | 2.392 | 0.000 | -6.661 | 0.000 | -5.611 | -0.000 |
F2 NW APARTMENT | 1.844 | -31.101 | 0.000 | 0.000 | 3.620 | 1.087 | 12.213 | 19.261 | 0.000 | 2.181 | 2.493 | 0.000 | -6.676 | 0.000 | -4.920 | -0.000 |
F2 SE APARTMENT | 0.519 | -43.681 | 0.000 | 0.000 | 3.563 | 1.087 | 12.213 | 31.376 | 0.000 | 2.185 | 4.923 | 0.000 | -6.508 | 0.000 | -5.676 | -0.001 |
F2 NE APARTMENT | 1.409 | -30.930 | 0.000 | 0.000 | 3.632 | 1.087 | 12.213 | 18.783 | 0.000 | 2.182 | 2.646 | 0.000 | -6.131 | 0.000 | -4.890 | -0.000 |
F2 N1 APARTMENT | 0.469 | -21.528 | 0.000 | 0.000 | 3.631 | 1.087 | 12.213 | 7.687 | 0.000 | 1.366 | 3.100 | 0.000 | -4.053 | 0.000 | -3.970 | -0.000 |
F2 N2 APARTMENT | 0.469 | -21.536 | 0.000 | 0.000 | 3.632 | 1.087 | 12.213 | 7.686 | 0.000 | 1.366 | 3.103 | 0.000 | -4.049 | 0.000 | -3.969 | -0.000 |
F2 S1 APARTMENT | 0.153 | -32.077 | 0.000 | 0.000 | 3.556 | 1.087 | 12.213 | 20.243 | 0.000 | 1.367 | 2.344 | 0.000 | -4.018 | 0.000 | -4.867 | -0.000 |
F2 S2 APARTMENT | 0.154 | -32.253 | 0.000 | 0.000 | 3.555 | 1.087 | 12.213 | 20.240 | 0.000 | 1.367 | 2.535 | 0.000 | -4.022 | 0.000 | -4.875 | -0.000 |
F3 SW APARTMENT | 0.639 | -43.093 | 0.000 | 0.000 | 3.558 | 1.087 | 12.213 | 31.208 | 0.000 | 2.598 | 4.722 | 0.000 | -6.799 | 0.000 | -6.132 | -0.001 |
F3 NW APARTMENT | 1.651 | -32.435 | 0.000 | 0.000 | 3.609 | 1.087 | 12.213 | 19.025 | 0.000 | 2.594 | 4.569 | 0.000 | -6.848 | 0.000 | -5.465 | -0.000 |
F3 SE APARTMENT | 0.460 | -43.374 | 0.000 | 0.000 | 3.562 | 1.087 | 12.213 | 31.028 | 0.000 | 2.599 | 5.143 | 0.000 | -6.577 | 0.000 | -6.141 | -0.001 |
F3 NE APARTMENT | 1.250 | -32.316 | 0.000 | 0.000 | 3.621 | 1.087 | 12.213 | 18.548 | 0.000 | 2.595 | 4.715 | 0.000 | -6.283 | 0.000 | -5.429 | -0.000 |
F3 N1 APARTMENT | 0.382 | -22.979 | 0.000 | 0.000 | 3.615 | 1.087 | 12.213 | 7.611 | 0.000 | 1.632 | 5.051 | 0.000 | -4.184 | 0.000 | -4.428 | 0.000 |
F3 N2 APARTMENT | 0.382 | -22.988 | 0.000 | 0.000 | 3.616 | 1.087 | 12.213 | 7.610 | 0.000 | 1.632 | 5.053 | 0.000 | -4.179 | 0.000 | -4.425 | 0.000 |
F3 S1 APARTMENT | 0.135 | -34.023 | 0.000 | 0.000 | 3.546 | 1.087 | 12.213 | 19.988 | 0.000 | 1.632 | 4.812 | 0.000 | -4.113 | 0.000 | -5.276 | -0.000 |
F3 S2 APARTMENT | 0.135 | -34.061 | 0.000 | 0.000 | 3.546 | 1.087 | 12.213 | 19.986 | 0.000 | 1.632 | 4.852 | 0.000 | -4.112 | 0.000 | -5.278 | -0.000 |
F4 SW APARTMENT | 0.638 | -43.523 | 0.000 | 0.000 | 3.557 | 1.087 | 12.213 | 30.921 | 0.000 | 2.884 | 5.350 | 0.000 | -6.856 | 0.000 | -6.270 | -0.000 |
F4 NW APARTMENT | 1.650 | -32.893 | 0.000 | 0.000 | 3.605 | 1.087 | 12.213 | 18.872 | 0.000 | 2.879 | 5.161 | 0.000 | -6.931 | 0.000 | -5.643 | 0.000 |
F4 SE APARTMENT | 0.468 | -43.563 | 0.000 | 0.000 | 3.562 | 1.087 | 12.213 | 30.754 | 0.000 | 2.885 | 5.485 | 0.000 | -6.620 | 0.000 | -6.271 | -0.000 |
F4 NE APARTMENT | 1.247 | -32.790 | 0.000 | 0.000 | 3.617 | 1.087 | 12.213 | 18.396 | 0.000 | 2.881 | 5.312 | 0.000 | -6.355 | 0.000 | -5.606 | 0.000 |
F4 N1 APARTMENT | 0.366 | -23.486 | 0.000 | 0.000 | 3.608 | 1.087 | 12.213 | 7.570 | 0.000 | 1.806 | 5.624 | 0.000 | -4.250 | 0.000 | -4.538 | 0.000 |
F4 N2 APARTMENT | 0.364 | -23.493 | 0.000 | 0.000 | 3.609 | 1.087 | 12.213 | 7.570 | 0.000 | 1.806 | 5.625 | 0.000 | -4.245 | 0.000 | -4.536 | 0.000 |
F4 S1 APARTMENT | 0.136 | -34.593 | 0.000 | 0.000 | 3.543 | 1.087 | 12.213 | 19.811 | 0.000 | 1.808 | 5.473 | 0.000 | -4.153 | 0.000 | -5.325 | -0.000 |
F4 S2 APARTMENT | 0.137 | -34.601 | 0.000 | 0.000 | 3.544 | 1.087 | 12.213 | 19.811 | 0.000 | 1.808 | 5.481 | 0.000 | -4.152 | 0.000 | -5.326 | -0.000 |
M SW APARTMENT | 0.681 | -44.062 | 0.000 | 0.000 | 3.557 | 1.087 | 12.213 | 30.681 | 0.000 | 3.116 | 6.210 | 0.000 | -6.901 | 0.000 | -6.581 | -0.001 |
M NW APARTMENT | 1.706 | -33.558 | 0.000 | 0.000 | 3.604 | 1.087 | 12.213 | 18.744 | 0.000 | 3.111 | 6.025 | 0.000 | -6.989 | 0.000 | -5.942 | 0.000 |
M SE APARTMENT | 0.504 | -44.065 | 0.000 | 0.000 | 3.562 | 1.087 | 12.213 | 30.517 | 0.000 | 3.118 | 6.305 | 0.000 | -6.661 | 0.000 | -6.581 | -0.001 |
M NE APARTMENT | 1.295 | -33.455 | 0.000 | 0.000 | 3.615 | 1.087 | 12.213 | 18.267 | 0.000 | 3.113 | 6.175 | 0.000 | -6.407 | 0.000 | -5.903 | 0.000 |
M N1 APARTMENT | 0.382 | -24.145 | 0.000 | 0.000 | 3.605 | 1.087 | 12.213 | 7.534 | 0.000 | 1.948 | 6.443 | 0.000 | -4.295 | 0.000 | -4.772 | 0.000 |
M N2 APARTMENT | 0.380 | -24.151 | 0.000 | 0.000 | 3.606 | 1.087 | 12.213 | 7.534 | 0.000 | 1.948 | 6.444 | 0.000 | -4.290 | 0.000 | -4.769 | 0.000 |
M S1 APARTMENT | 0.147 | -35.197 | 0.000 | 0.000 | 3.543 | 1.087 | 12.213 | 19.663 | 0.000 | 1.951 | 6.337 | 0.000 | -4.183 | 0.000 | -5.559 | -0.000 |
M S2 APARTMENT | 0.147 | -35.200 | 0.000 | 0.000 | 3.543 | 1.087 | 12.213 | 19.663 | 0.000 | 1.951 | 6.338 | 0.000 | -4.182 | 0.000 | -5.559 | -0.000 |
F6 SW APARTMENT | 0.775 | -43.160 | 0.000 | 0.000 | 3.561 | 1.087 | 12.213 | 30.514 | 0.000 | 3.314 | 5.408 | 0.000 | -6.894 | 0.000 | -6.818 | -0.000 |
F6 NW APARTMENT | 1.890 | -33.006 | 0.000 | 0.000 | 3.610 | 1.087 | 12.213 | 18.677 | 0.000 | 3.308 | 5.319 | 0.000 | -6.972 | 0.000 | -6.126 | 0.000 |
F6 SE APARTMENT | 0.583 | -43.149 | 0.000 | 0.000 | 3.567 | 1.087 | 12.213 | 30.354 | 0.000 | 3.316 | 5.499 | 0.000 | -6.651 | 0.000 | -6.818 | -0.000 |
F6 NE APARTMENT | 1.458 | -32.881 | 0.000 | 0.000 | 3.622 | 1.087 | 12.213 | 18.203 | 0.000 | 3.310 | 5.464 | 0.000 | -6.389 | 0.000 | -6.086 | 0.000 |
F6 N1 APARTMENT | 0.429 | -23.555 | 0.000 | 0.000 | 3.612 | 1.087 | 12.213 | 7.530 | 0.000 | 2.069 | 5.791 | 0.000 | -4.285 | 0.000 | -4.889 | 0.000 |
F6 N2 APARTMENT | 0.428 | -23.563 | 0.000 | 0.000 | 3.613 | 1.087 | 12.213 | 7.529 | 0.000 | 2.069 | 5.792 | 0.000 | -4.280 | 0.000 | -4.887 | 0.000 |
F6 S1 APARTMENT | 0.162 | -34.277 | 0.000 | 0.000 | 3.547 | 1.087 | 12.213 | 19.561 | 0.000 | 2.072 | 5.548 | 0.000 | -4.182 | 0.000 | -5.730 | -0.001 |
F6 S2 APARTMENT | 0.163 | -34.278 | 0.000 | 0.000 | 3.547 | 1.087 | 12.213 | 19.561 | 0.000 | 2.072 | 5.547 | 0.000 | -4.180 | 0.000 | -5.730 | -0.001 |
F7 SW APARTMENT | 0.856 | -42.761 | 0.000 | 0.000 | 3.565 | 1.087 | 12.213 | 30.356 | 0.000 | 3.487 | 5.108 | 0.000 | -6.896 | 0.000 | -7.014 | -0.000 |
F7 NW APARTMENT | 2.050 | -32.863 | 0.000 | 0.000 | 3.615 | 1.087 | 12.213 | 18.607 | 0.000 | 3.480 | 5.065 | 0.000 | -6.969 | 0.000 | -6.285 | 0.000 |
F7 SE APARTMENT | 0.653 | -42.742 | 0.000 | 0.000 | 3.571 | 1.087 | 12.213 | 30.197 | 0.000 | 3.489 | 5.199 | 0.000 | -6.653 | 0.000 | -7.013 | -0.000 |
F7 NE APARTMENT | 1.606 | -32.728 | 0.000 | 0.000 | 3.626 | 1.087 | 12.213 | 18.134 | 0.000 | 3.482 | 5.210 | 0.000 | -6.385 | 0.000 | -6.245 | 0.000 |
F7 N1 APARTMENT | 0.478 | -23.372 | 0.000 | 0.000 | 3.617 | 1.087 | 12.213 | 7.518 | 0.000 | 2.174 | 5.558 | 0.000 | -4.283 | 0.000 | -4.990 | 0.000 |
F7 N2 APARTMENT | 0.480 | -23.380 | 0.000 | 0.000 | 3.618 | 1.087 | 12.213 | 7.517 | 0.000 | 2.174 | 5.558 | 0.000 | -4.278 | 0.000 | -4.988 | 0.000 |
F7 S1 APARTMENT | 0.177 | -33.865 | 0.000 | 0.000 | 3.550 | 1.087 | 12.213 | 19.464 | 0.000 | 2.178 | 5.249 | 0.000 | -4.186 | 0.000 | -5.867 | -0.000 |
F7 S2 APARTMENT | 0.178 | -33.866 | 0.000 | 0.000 | 3.550 | 1.087 | 12.213 | 19.463 | 0.000 | 2.178 | 5.248 | 0.000 | -4.184 | 0.000 | -5.867 | -0.000 |
F8 SW APARTMENT | 0.945 | -42.621 | 0.000 | 0.000 | 3.568 | 1.087 | 12.213 | 30.209 | 0.000 | 3.644 | 5.074 | 0.000 | -6.902 | 0.000 | -7.216 | -0.000 |
F8 NW APARTMENT | 2.211 | -32.962 | 0.000 | 0.000 | 3.619 | 1.087 | 12.213 | 18.537 | 0.000 | 3.637 | 5.085 | 0.000 | -6.972 | 0.000 | -6.454 | 0.000 |
F8 SE APARTMENT | 0.727 | -42.595 | 0.000 | 0.000 | 3.574 | 1.087 | 12.213 | 30.050 | 0.000 | 3.647 | 5.169 | 0.000 | -6.657 | 0.000 | -7.214 | -0.000 |
F8 NE APARTMENT | 1.759 | -32.818 | 0.000 | 0.000 | 3.630 | 1.087 | 12.213 | 18.063 | 0.000 | 3.640 | 5.229 | 0.000 | -6.387 | 0.000 | -6.414 | 0.000 |
F8 N1 APARTMENT | 0.539 | -23.427 | 0.000 | 0.000 | 3.621 | 1.087 | 12.213 | 7.502 | 0.000 | 2.271 | 5.588 | 0.000 | -4.284 | 0.000 | -5.108 | 0.000 |
F8 N2 APARTMENT | 0.541 | -23.436 | 0.000 | 0.000 | 3.622 | 1.087 | 12.213 | 7.501 | 0.000 | 2.271 | 5.588 | 0.000 | -4.280 | 0.000 | -5.106 | 0.000 |
F8 S1 APARTMENT | 0.195 | -33.706 | 0.000 | 0.000 | 3.553 | 1.087 | 12.213 | 19.373 | 0.000 | 2.276 | 5.216 | 0.000 | -4.190 | 0.000 | -6.016 | -0.000 |
F8 S2 APARTMENT | 0.196 | -33.709 | 0.000 | 0.000 | 3.553 | 1.087 | 12.213 | 19.372 | 0.000 | 2.276 | 5.217 | 0.000 | -4.189 | 0.000 | -6.017 | -0.000 |
F9 SW APARTMENT | 1.154 | -43.390 | 0.000 | 0.000 | 3.572 | 1.087 | 12.213 | 30.057 | 0.000 | 3.791 | 5.804 | 0.000 | -6.900 | 0.000 | -7.388 | -0.000 |
F9 NW APARTMENT | 2.535 | -34.021 | 0.000 | 0.000 | 3.621 | 1.087 | 12.213 | 18.449 | 0.000 | 3.783 | 5.916 | 0.000 | -6.979 | 0.000 | -6.603 | -0.000 |
F9 SE APARTMENT | 0.886 | -43.339 | 0.000 | 0.000 | 3.578 | 1.087 | 12.213 | 29.897 | 0.000 | 3.793 | 5.922 | 0.000 | -6.652 | 0.000 | -7.385 | -0.000 |
F9 NE APARTMENT | 2.017 | -33.842 | 0.000 | 0.000 | 3.632 | 1.087 | 12.213 | 17.976 | 0.000 | 3.785 | 6.091 | 0.000 | -6.394 | 0.000 | -6.564 | 0.000 |
F9 N1 APARTMENT | 0.675 | -24.304 | 0.000 | 0.000 | 3.623 | 1.087 | 12.213 | 7.471 | 0.000 | 2.362 | 6.374 | 0.000 | -4.288 | 0.000 | -5.213 | 0.000 |
F9 N2 APARTMENT | 0.677 | -24.316 | 0.000 | 0.000 | 3.624 | 1.087 | 12.213 | 7.470 | 0.000 | 2.362 | 6.378 | 0.000 | -4.284 | 0.000 | -5.211 | 0.000 |
F9 S1 APARTMENT | 0.237 | -34.320 | 0.000 | 0.000 | 3.558 | 1.087 | 12.213 | 19.281 | 0.000 | 2.369 | 5.905 | 0.000 | -4.188 | 0.000 | -6.140 | -0.000 |
F9 S2 APARTMENT | 0.238 | -34.327 | 0.000 | 0.000 | 3.558 | 1.087 | 12.213 | 19.280 | 0.000 | 2.369 | 5.909 | 0.000 | -4.186 | 0.000 | -6.140 | -0.000 |
T SW APARTMENT | 2.974 | -47.191 | 0.000 | 0.000 | 3.604 | 1.087 | 12.213 | 29.531 | 0.000 | 3.919 | 7.810 | 0.000 | -6.556 | 0.000 | -7.391 | -0.000 |
T NW APARTMENT | 4.464 | -37.937 | 0.000 | 0.000 | 3.637 | 1.087 | 12.213 | 17.977 | 0.000 | 3.911 | 8.126 | 0.000 | -6.711 | 0.000 | -6.765 | -0.000 |
T SE APARTMENT | 2.594 | -46.886 | 0.000 | 0.000 | 3.611 | 1.087 | 12.213 | 29.383 | 0.000 | 3.921 | 7.819 | 0.000 | -6.329 | 0.000 | -7.412 | -0.000 |
T NE APARTMENT | 3.775 | -37.400 | 0.000 | 0.000 | 3.649 | 1.087 | 12.213 | 17.553 | 0.000 | 3.912 | 8.162 | 0.000 | -6.184 | 0.000 | -6.766 | -0.000 |
T N1 APARTMENT | 1.725 | -27.826 | 0.000 | 0.000 | 3.639 | 1.087 | 12.213 | 7.277 | 0.000 | 2.441 | 8.917 | 0.000 | -4.124 | 0.000 | -5.349 | -0.000 |
T N2 APARTMENT | 1.734 | -27.836 | 0.000 | 0.000 | 3.640 | 1.087 | 12.213 | 7.275 | 0.000 | 2.441 | 8.919 | 0.000 | -4.120 | 0.000 | -5.352 | -0.000 |
T S1 APARTMENT | 0.889 | -37.443 | 0.000 | 0.000 | 3.590 | 1.087 | 12.213 | 18.992 | 0.000 | 2.448 | 8.360 | 0.000 | -4.003 | 0.000 | -6.133 | -0.000 |
T S2 APARTMENT | 0.896 | -37.459 | 0.000 | 0.000 | 3.591 | 1.087 | 12.213 | 18.990 | 0.000 | 2.448 | 8.369 | 0.000 | -4.001 | 0.000 | -6.134 | -0.000 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 7.095 | 0.000 | 16.182 | 0.000 | 0.000 | -1.387 | 0.000 | -17.050 | -21.279 |
F2 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 3.464 | 0.000 | 0.251 | 0.000 | 0.000 | -0.877 | 0.000 | -0.342 | -18.935 |
F3 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 3.398 | 0.000 | 0.296 | 0.000 | 0.000 | -0.914 | 0.000 | -0.424 | -18.796 |
F4 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 3.348 | 0.000 | 0.326 | 0.000 | 0.000 | -0.932 | 0.000 | -0.482 | -18.699 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32.880 | 0.000 | 3.264 | 0.000 | 0.327 | 0.000 | 0.000 | -0.977 | 0.000 | -0.561 | -34.933 |
F6 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 3.297 | 0.000 | 0.376 | 0.000 | 0.000 | -0.939 | 0.000 | -0.560 | -18.615 |
F7 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 3.288 | 0.000 | 0.400 | 0.000 | 0.000 | -0.932 | 0.000 | -0.584 | -18.612 |
F8 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 3.270 | 0.000 | 0.417 | 0.000 | 0.000 | -0.931 | 0.000 | -0.610 | -18.585 |
F9 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 3.241 | 0.000 | 0.423 | 0.000 | 0.000 | -0.935 | 0.000 | -0.634 | -18.535 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 8.151 | 3.065 | 0.000 | 0.341 | 0.000 | 0.000 | -0.917 | 0.000 | -0.691 | -26.389 |
Total Facility | 76.750 | -2622.678 | 0.000 | 0.000 | 284.666 | 296.560 | 982.450 | 1567.113 | 0.000 | 217.337 | 399.756 | 0.000 | -438.202 | 0.000 | -466.346 | -297.414 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 29-SEP-14:30 | 0.00 | -3877.65 | 0.00 | 0.00 | 39.29 | 22.70 | 400.26 | 5017.68 | 0.00 | 142.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1744.52 |
G NW APARTMENT | 02-JUL-17:20 | 0.00 | -3651.03 | 0.00 | 0.00 | 138.17 | 87.56 | 588.62 | 3488.19 | 0.00 | 349.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1001.29 |
OFFICE | 29-SEP-10:30 | 0.00 | -5008.90 | 0.00 | 0.00 | 65.20 | 2345.88 | 588.62 | 4570.30 | 0.00 | 78.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2639.20 |
G NE APARTMENT | 16-JUL-17:20 | 0.00 | -2863.29 | 0.00 | 0.00 | 138.77 | 87.56 | 588.62 | 1964.91 | 0.00 | 438.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -354.59 |
G N1 APARTMENT | 02-JUL-17:20 | 0.00 | -1960.41 | 0.00 | 0.00 | 140.43 | 87.56 | 588.62 | 1107.70 | 0.00 | 213.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -177.70 |
G N2 APARTMENT | 02-JUL-17:20 | 0.00 | -1948.46 | 0.00 | 0.00 | 140.43 | 87.56 | 588.62 | 1107.97 | 0.00 | 213.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -189.92 |
G S1 APARTMENT | 01-OCT-11:45 | 0.00 | -2402.12 | 0.00 | 0.00 | 40.54 | 12.97 | 406.15 | 3421.42 | 0.00 | 74.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1553.11 |
G S2 APARTMENT | 01-OCT-12:00 | 0.00 | -2462.11 | 0.00 | 0.00 | 40.44 | 12.97 | 406.15 | 3468.89 | 0.00 | 80.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1547.00 |
F2 SW APARTMENT | 29-SEP-14:30 | 0.00 | -4445.61 | 0.00 | 0.00 | 39.63 | 22.70 | 400.26 | 4959.16 | 0.00 | 206.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1182.13 |
F2 NW APARTMENT | 02-JUL-17:20 | 0.00 | -4172.57 | 0.00 | 0.00 | 139.31 | 87.56 | 588.62 | 3422.44 | 0.00 | 505.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -571.17 |
F2 SE APARTMENT | 02-SEP-11:00 | 0.00 | -4125.64 | 0.00 | 0.00 | 40.70 | 12.97 | 412.03 | 3844.42 | 0.00 | 372.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -557.07 |
F2 NE APARTMENT | 09-JUL-17:00 | 0.00 | -3359.46 | 0.00 | 0.00 | 83.99 | 64.86 | 588.62 | 1444.71 | 0.00 | 829.28 | 348.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 N1 APARTMENT | 02-JUL-17:45 | 0.00 | -2274.15 | 0.00 | 0.00 | 140.26 | 87.56 | 588.62 | 1105.47 | 0.00 | 304.44 | 47.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 N2 APARTMENT | 02-JUL-17:45 | 0.00 | -2264.23 | 0.00 | 0.00 | 140.26 | 87.56 | 588.62 | 1105.40 | 0.00 | 304.45 | 37.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 S1 APARTMENT | 15-OCT-12:15 | 0.00 | -2879.30 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 3195.42 | 0.00 | 24.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -783.28 |
F2 S2 APARTMENT | 15-OCT-12:30 | 0.00 | -2894.09 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 3153.87 | 0.00 | 32.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -734.10 |
F3 SW APARTMENT | 08-OCT-14:30 | 0.00 | -4464.07 | 0.00 | 0.00 | 40.63 | 22.70 | 400.26 | 4762.10 | 0.00 | 217.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -979.12 |
F3 NW APARTMENT | 27-JUN-17:20 | 0.00 | -4203.45 | 0.00 | 0.00 | 139.65 | 87.56 | 588.62 | 3613.46 | 0.00 | 368.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -594.19 |
F3 SE APARTMENT | 14-OCT-12:45 | 0.00 | -3958.95 | 0.00 | 0.00 | 40.74 | 12.97 | 388.49 | 3789.72 | 0.00 | 235.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -508.47 |
F3 NE APARTMENT | 09-JUL-17:00 | 0.00 | -3421.02 | 0.00 | 0.00 | 83.51 | 64.86 | 588.62 | 1449.08 | 0.00 | 974.69 | 260.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 N1 APARTMENT | 02-JUL-18:00 | 0.00 | -2302.22 | 0.00 | 0.00 | 139.73 | 87.56 | 588.62 | 1078.31 | 0.00 | 356.24 | 51.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 N2 APARTMENT | 02-JUL-18:15 | 0.00 | -2292.46 | 0.00 | 0.00 | 139.79 | 103.77 | 547.42 | 1028.96 | 0.00 | 366.94 | 105.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 S1 APARTMENT | 21-NOV-13:00 | 0.00 | -2962.53 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 3345.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2.50 | -840.49 |
F3 S2 APARTMENT | 21-NOV-13:00 | 0.00 | -2971.07 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 3345.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2.46 | -831.87 |
F4 SW APARTMENT | 29-SEP-14:30 | 0.00 | -4496.26 | 0.00 | 0.00 | 39.80 | 22.70 | 400.26 | 4896.23 | 0.00 | 272.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1135.59 |
F4 NW APARTMENT | 27-JUN-17:20 | 0.00 | -4237.65 | 0.00 | 0.00 | 139.67 | 87.56 | 588.62 | 3591.80 | 0.00 | 411.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -581.25 |
F4 SE APARTMENT | 08-OCT-13:45 | 0.00 | -3965.25 | 0.00 | 0.00 | 40.63 | 12.97 | 382.60 | 3668.03 | 0.00 | 207.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -346.75 |
F4 NE APARTMENT | 09-JUL-17:00 | 0.00 | -3475.20 | 0.00 | 0.00 | 83.12 | 64.86 | 588.62 | 1450.44 | 0.00 | 1082.83 | 205.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 N1 APARTMENT | 02-JUL-18:30 | 0.00 | -2340.38 | 0.00 | 0.00 | 139.77 | 103.77 | 547.42 | 932.24 | 0.00 | 420.74 | 196.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 N2 APARTMENT | 02-JUL-18:30 | 0.00 | -2331.09 | 0.00 | 0.00 | 139.81 | 103.77 | 547.42 | 932.59 | 0.00 | 420.83 | 186.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 S1 APARTMENT | 21-NOV-13:00 | 0.00 | -2993.02 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 3330.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3.17 | -794.34 |
F4 S2 APARTMENT | 21-NOV-13:00 | 0.00 | -2999.78 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 3330.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3.16 | -787.49 |
M SW APARTMENT | 29-SEP-14:30 | 0.00 | -4554.73 | 0.00 | 0.00 | 39.89 | 22.70 | 400.26 | 4874.47 | 0.00 | 296.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1079.41 |
M NW APARTMENT | 27-JUN-17:20 | 0.00 | -4291.22 | 0.00 | 0.00 | 139.72 | 87.56 | 588.62 | 3573.46 | 0.00 | 446.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -544.66 |
M SE APARTMENT | 02-SEP-10:15 | 0.00 | -4018.49 | 0.00 | 0.00 | 40.65 | 12.97 | 412.03 | 3586.86 | 0.00 | 618.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -652.03 |
M NE APARTMENT | 09-JUL-17:00 | 0.00 | -3546.23 | 0.00 | 0.00 | 82.83 | 64.86 | 588.62 | 1450.13 | 0.00 | 1170.88 | 188.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N1 APARTMENT | 02-JUL-18:45 | 0.00 | -2402.64 | 0.00 | 0.00 | 140.01 | 103.77 | 547.42 | 883.24 | 0.00 | 468.25 | 259.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 02-JUL-18:45 | 0.00 | -2393.45 | 0.00 | 0.00 | 140.04 | 103.77 | 547.42 | 883.59 | 0.00 | 468.33 | 250.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | 21-NOV-13:30 | 0.00 | -3028.61 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 3204.43 | 0.00 | 14.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -632.97 |
M S2 APARTMENT | 21-NOV-13:30 | 0.00 | -3032.98 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 3204.34 | 0.00 | 14.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -628.51 |
F6 SW APARTMENT | 29-SEP-14:30 | 0.00 | -4542.45 | 0.00 | 0.00 | 39.95 | 22.70 | 400.26 | 4857.04 | 0.00 | 317.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1094.66 |
F6 NW APARTMENT | 17-JUN-16:30 | 0.00 | -4277.17 | 0.00 | 0.00 | 84.33 | 64.86 | 588.62 | 3305.59 | 0.00 | 715.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -481.96 |
F6 SE APARTMENT | 02-SEP-10:15 | 0.00 | -4004.46 | 0.00 | 0.00 | 40.67 | 12.97 | 412.03 | 3547.91 | 0.00 | 659.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -668.90 |
F6 NE APARTMENT | 09-JUL-17:00 | 0.00 | -3549.06 | 0.00 | 0.00 | 82.53 | 64.86 | 588.62 | 1450.68 | 0.00 | 1245.07 | 117.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 N1 APARTMENT | 02-JUL-19:00 | 0.00 | -2391.32 | 0.00 | 0.00 | 140.08 | 103.77 | 547.42 | 787.11 | 0.00 | 511.39 | 301.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 N2 APARTMENT | 02-JUL-19:00 | 0.00 | -2382.41 | 0.00 | 0.00 | 140.11 | 103.77 | 547.42 | 787.43 | 0.00 | 511.46 | 292.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 S1 APARTMENT | 21-NOV-13:30 | 0.00 | -2984.55 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 3193.99 | 0.00 | 14.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -665.95 |
F6 S2 APARTMENT | 21-NOV-13:30 | 0.00 | -2988.95 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 3193.90 | 0.00 | 14.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -661.46 |
F7 SW APARTMENT | 29-SEP-14:30 | 0.00 | -4551.74 | 0.00 | 0.00 | 40.01 | 22.70 | 400.26 | 4841.39 | 0.00 | 335.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1087.80 |
F7 NW APARTMENT | 17-JUN-16:30 | 0.00 | -4293.89 | 0.00 | 0.00 | 84.31 | 64.86 | 588.62 | 3288.28 | 0.00 | 755.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -487.58 |
F7 SE APARTMENT | 02-SEP-10:15 | 0.00 | -4012.18 | 0.00 | 0.00 | 40.69 | 12.97 | 412.03 | 3514.18 | 0.00 | 696.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -664.30 |
F7 NE APARTMENT | 09-JUL-17:00 | 0.00 | -3580.15 | 0.00 | 0.00 | 82.35 | 64.86 | 588.62 | 1450.87 | 0.00 | 1311.13 | 82.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 N1 APARTMENT | 03-JUL-18:00 | 0.00 | -2411.97 | 0.00 | 0.00 | 140.48 | 87.56 | 588.62 | 1022.82 | 0.00 | 515.43 | 57.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 N2 APARTMENT | 03-JUL-18:00 | 0.00 | -2403.04 | 0.00 | 0.00 | 140.48 | 87.56 | 588.62 | 1023.04 | 0.00 | 515.47 | 47.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 S1 APARTMENT | 21-NOV-13:30 | 0.00 | -2960.74 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 3184.11 | 0.00 | 13.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -679.03 |
F7 S2 APARTMENT | 21-NOV-13:30 | 0.00 | -2965.18 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 3184.02 | 0.00 | 13.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -674.50 |
F8 SW APARTMENT | 29-SEP-14:30 | 0.00 | -4576.82 | 0.00 | 0.00 | 40.08 | 22.70 | 400.26 | 4827.40 | 0.00 | 351.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1065.15 |
F8 NW APARTMENT | 17-JUN-16:30 | 0.00 | -4325.33 | 0.00 | 0.00 | 84.29 | 64.86 | 588.62 | 3272.60 | 0.00 | 790.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -475.99 |
F8 SE APARTMENT | 02-SEP-10:15 | 0.00 | -4035.55 | 0.00 | 0.00 | 40.71 | 12.97 | 412.03 | 3484.34 | 0.00 | 729.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -644.30 |
F8 NE APARTMENT | 09-JUL-17:00 | 0.00 | -3617.54 | 0.00 | 0.00 | 82.16 | 64.86 | 588.62 | 1449.76 | 0.00 | 1369.55 | 62.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 N1 APARTMENT | 03-JUL-18:00 | 0.00 | -2436.58 | 0.00 | 0.00 | 140.39 | 87.56 | 588.62 | 1022.36 | 0.00 | 539.41 | 58.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 N2 APARTMENT | 03-JUL-18:00 | 0.00 | -2427.75 | 0.00 | 0.00 | 140.39 | 87.56 | 588.62 | 1022.59 | 0.00 | 539.46 | 49.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 S1 APARTMENT | 27-FEB-13:00 | 0.00 | -2965.59 | 0.00 | 0.00 | 40.55 | 12.97 | 406.15 | 3433.94 | 0.00 | 47.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -975.95 |
F8 S2 APARTMENT | 27-FEB-13:00 | 0.00 | -2971.28 | 0.00 | 0.00 | 40.54 | 12.97 | 406.15 | 3433.67 | 0.00 | 47.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -969.93 |
F9 SW APARTMENT | 29-SEP-14:30 | 0.00 | -4716.23 | 0.00 | 0.00 | 40.25 | 22.70 | 400.26 | 4814.39 | 0.00 | 367.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -928.92 |
F9 NW APARTMENT | 17-JUN-16:30 | 0.00 | -4476.89 | 0.00 | 0.00 | 84.33 | 64.86 | 588.62 | 3254.84 | 0.00 | 823.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -339.55 |
F9 SE APARTMENT | 02-SEP-10:15 | 0.00 | -4133.82 | 0.00 | 0.00 | 40.75 | 12.97 | 412.03 | 3456.42 | 0.00 | 761.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -549.83 |
F9 NE APARTMENT | 09-JUL-17:00 | 0.00 | -3728.93 | 0.00 | 0.00 | 81.80 | 64.86 | 588.62 | 1442.33 | 0.00 | 1419.64 | 131.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 N1 APARTMENT | 03-JUL-18:00 | 0.00 | -2567.58 | 0.00 | 0.00 | 140.46 | 87.56 | 588.62 | 1019.72 | 0.00 | 561.77 | 169.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 N2 APARTMENT | 03-JUL-18:00 | 0.00 | -2566.18 | 0.00 | 0.00 | 140.55 | 87.56 | 588.62 | 1020.22 | 0.00 | 562.14 | 167.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 S1 APARTMENT | 27-FEB-13:15 | 0.00 | -3055.66 | 0.00 | 0.00 | 40.70 | 12.97 | 388.49 | 3421.67 | 0.00 | 55.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -863.72 |
F9 S2 APARTMENT | 27-FEB-13:15 | 0.00 | -3062.13 | 0.00 | 0.00 | 40.70 | 12.97 | 388.49 | 3421.45 | 0.00 | 55.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -856.99 |
T SW APARTMENT | 29-SEP-14:30 | 0.00 | -5742.46 | 0.00 | 0.00 | 40.26 | 22.70 | 400.26 | 4744.34 | 0.00 | 380.76 | 154.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 17-JUN-16:30 | 0.00 | -5406.05 | 0.00 | 0.00 | 84.59 | 64.86 | 588.62 | 3192.22 | 0.00 | 856.70 | 619.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SE APARTMENT | 29-SEP-14:30 | 0.00 | -5099.47 | 0.00 | 0.00 | 40.25 | 22.70 | 400.26 | 3373.17 | 0.00 | 383.87 | 879.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 09-JUL-17:00 | 0.00 | -4477.73 | 0.00 | 0.00 | 82.81 | 64.86 | 588.62 | 1409.39 | 0.00 | 1489.94 | 842.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 02-JUL-17:30 | 0.00 | -3379.34 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 1087.34 | 0.00 | 565.15 | 908.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 02-JUL-17:30 | 0.00 | -3359.94 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 1087.84 | 0.00 | 565.35 | 888.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 08-OCT-13:30 | 0.00 | -4036.37 | 0.00 | 0.00 | 39.65 | 12.97 | 382.60 | 3187.60 | 0.00 | 138.15 | 275.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S2 APARTMENT | 08-OCT-13:30 | 0.00 | -4042.22 | 0.00 | 0.00 | 39.64 | 12.97 | 382.60 | 3187.28 | 0.00 | 138.11 | 281.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 09-JUL-17:00 | 0.00 | -257356.22 | 0.00 | 0.00 | 6575.65 | 11327.17 | 47212.47 | 110341.63 | 0.00 | 82697.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -798.38 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 07-MAR-03:00 | 1026.04 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 95.43 | 0.00 | -1325.64 | 0.00 | -221.55 | 0.00 |
G NW APARTMENT | 25-JAN-10:40 | 1236.00 | 0.00 | 0.00 | 0.00 | 46.68 | 12.97 | 406.15 | 86.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1191.67 | -596.93 |
OFFICE | 07-MAR-03:00 | 852.67 | 0.00 | 0.00 | 0.00 | 0.00 | 469.18 | 194.24 | 0.00 | 0.00 | 0.00 | 51.15 | 0.00 | -1345.69 | 0.00 | -221.55 | 0.00 |
G NE APARTMENT | 21-DEC-13:00 | 1059.85 | 0.00 | 0.00 | 0.00 | 44.23 | 12.97 | 406.15 | 124.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1352.82 | -295.37 |
G N1 APARTMENT | 06-FEB-10:55 | 1186.77 | 0.00 | 0.00 | 0.00 | 46.05 | 12.97 | 406.15 | 174.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1246.30 | -579.87 |
G N2 APARTMENT | 06-FEB-10:55 | 1182.56 | 0.00 | 0.00 | 0.00 | 46.05 | 12.97 | 406.15 | 174.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1246.39 | -575.42 |
G S1 APARTMENT | 07-MAR-03:00 | 467.70 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 50.22 | 0.00 | -810.01 | 0.00 | -133.63 | 0.00 |
G S2 APARTMENT | 07-MAR-03:00 | 451.74 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 67.13 | 0.00 | -810.96 | 0.00 | -133.63 | 0.00 |
F2 SW APARTMENT | 07-MAR-03:00 | 933.48 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 305.54 | 0.00 | -1345.96 | 0.00 | -318.78 | 0.00 |
F2 NW APARTMENT | 06-FEB-11:00 | 1152.78 | 0.00 | 0.00 | 0.00 | 44.12 | 12.97 | 406.15 | 194.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1603.50 | -206.83 |
F2 SE APARTMENT | 07-MAR-03:00 | 873.41 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 372.05 | 0.00 | -1352.39 | 0.00 | -318.78 | 0.00 |
F2 NE APARTMENT | 07-MAR-03:00 | 975.98 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 257.48 | 0.00 | -1340.39 | 0.00 | -318.78 | 0.00 |
F2 N1 APARTMENT | 06-FEB-11:00 | 1235.34 | 0.00 | 0.00 | 0.00 | 44.35 | 12.97 | 406.15 | 124.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1494.49 | -328.65 |
F2 N2 APARTMENT | 06-FEB-11:00 | 1231.90 | 0.00 | 0.00 | 0.00 | 44.37 | 12.97 | 406.15 | 124.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1494.42 | -325.52 |
F2 S1 APARTMENT | 07-MAR-03:00 | 340.04 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 252.87 | 0.00 | -826.35 | 0.00 | -192.28 | 0.00 |
F2 S2 APARTMENT | 07-MAR-05:00 | 333.85 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 224.91 | 0.00 | -825.48 | 0.00 | -166.09 | 0.00 |
F3 SW APARTMENT | 07-MAR-03:00 | 905.13 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 404.71 | 0.00 | -1357.73 | 0.00 | -377.83 | 0.00 |
F3 NW APARTMENT | 06-FEB-11:00 | 1295.65 | 0.00 | 0.00 | 0.00 | 43.67 | 12.97 | 406.15 | 156.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1795.64 | -119.07 |
F3 SE APARTMENT | 07-MAR-03:00 | 906.83 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 402.82 | 0.00 | -1357.55 | 0.00 | -377.83 | 0.00 |
F3 NE APARTMENT | 21-DEC-13:00 | 1194.94 | 0.00 | 0.00 | 0.00 | 42.55 | 12.97 | 406.15 | 13.33 | 0.00 | 0.00 | 206.14 | 0.00 | 0.00 | 0.00 | -1876.08 | 0.00 |
F3 N1 APARTMENT | 21-DEC-13:00 | 1661.74 | 0.00 | 0.00 | 0.00 | 42.79 | 12.97 | 406.15 | 12.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1731.68 | -404.81 |
F3 N2 APARTMENT | 21-DEC-13:00 | 1613.46 | 0.00 | 0.00 | 0.00 | 42.77 | 12.97 | 406.15 | 12.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1732.64 | -355.28 |
F3 S1 APARTMENT | 07-MAR-05:00 | 245.07 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 352.52 | 0.00 | -833.54 | 0.00 | -196.85 | 0.00 |
F3 S2 APARTMENT | 07-MAR-05:00 | 244.39 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 353.22 | 0.00 | -833.57 | 0.00 | -196.85 | 0.00 |
F4 SW APARTMENT | 07-MAR-03:00 | 925.46 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 434.43 | 0.00 | -1362.85 | 0.00 | -422.76 | 0.00 |
F4 NW APARTMENT | 02-JAN-10:45 | 1400.70 | 0.00 | 0.00 | 0.00 | 43.76 | 12.97 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -14.22 | 0.00 | -1759.65 | -89.70 |
F4 SE APARTMENT | 07-MAR-03:00 | 937.74 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 420.65 | 0.00 | -1361.35 | 0.00 | -422.76 | 0.00 |
F4 NE APARTMENT | 06-FEB-12:15 | 1001.16 | 0.00 | 0.00 | 0.00 | 42.93 | 12.97 | 406.15 | 296.06 | 0.00 | 0.00 | 59.70 | 0.00 | 0.00 | 0.00 | -1818.97 | 0.00 |
F4 N1 APARTMENT | 02-JAN-10:45 | 1445.51 | 0.00 | 0.00 | 0.00 | 43.42 | 12.97 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -23.49 | 0.00 | -1637.88 | -246.68 |
F4 N2 APARTMENT | 02-JAN-10:45 | 1471.16 | 0.00 | 0.00 | 0.00 | 43.42 | 12.97 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -23.68 | 0.00 | -1637.44 | -272.57 |
F4 S1 APARTMENT | 04-MAY-15:55 | 228.85 | 0.00 | 0.00 | 0.00 | 48.90 | 45.40 | 470.89 | 33.04 | 0.00 | 0.00 | 468.62 | 0.00 | 0.00 | 0.00 | -1295.71 | 0.00 |
F4 S2 APARTMENT | 07-MAR-03:00 | 295.24 | 0.00 | 0.00 | 0.00 | 190.95 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 366.74 | 0.00 | -834.41 | 0.00 | -254.56 | 0.00 |
M SW APARTMENT | 07-MAR-03:00 | 944.85 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 455.91 | 0.00 | -1366.55 | 0.00 | -459.93 | 0.00 |
M NW APARTMENT | 02-JAN-10:45 | 1678.48 | 0.00 | 0.00 | 0.00 | 43.83 | 12.97 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -27.05 | 0.00 | -1867.60 | -246.78 |
M SE APARTMENT | 07-MAR-03:00 | 959.68 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 439.36 | 0.00 | -1364.83 | 0.00 | -459.93 | 0.00 |
M NE APARTMENT | 06-FEB-12:15 | 1362.80 | 0.00 | 0.00 | 0.00 | 43.07 | 12.97 | 406.15 | 279.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1929.63 | -174.82 |
M N1 APARTMENT | 02-JAN-10:45 | 1713.51 | 0.00 | 0.00 | 0.00 | 43.38 | 12.97 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -33.73 | 0.00 | -1738.23 | -404.05 |
M N2 APARTMENT | 02-JAN-10:45 | 1695.03 | 0.00 | 0.00 | 0.00 | 43.38 | 12.97 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -33.90 | 0.00 | -1738.18 | -385.45 |
M S1 APARTMENT | 04-MAY-15:55 | 244.55 | 0.00 | 0.00 | 0.00 | 48.90 | 45.40 | 470.89 | 27.68 | 0.00 | 0.00 | 542.44 | 0.00 | 0.00 | 0.00 | -1379.86 | 0.00 |
M S2 APARTMENT | 04-MAY-15:55 | 244.99 | 0.00 | 0.00 | 0.00 | 48.90 | 45.40 | 470.89 | 27.60 | 0.00 | 0.00 | 543.25 | 0.00 | 0.00 | 0.00 | -1381.03 | 0.00 |
F6 SW APARTMENT | 07-MAR-03:00 | 1009.56 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 421.89 | 0.00 | -1365.09 | 0.00 | -492.07 | 0.00 |
F6 NW APARTMENT | 25-JAN-10:40 | 1858.78 | 0.00 | 0.00 | 0.00 | 45.86 | 12.97 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -33.11 | 0.00 | -1850.26 | -440.39 |
F6 SE APARTMENT | 07-MAR-03:00 | 1021.76 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 408.18 | 0.00 | -1363.58 | 0.00 | -492.07 | 0.00 |
F6 NE APARTMENT | 06-FEB-12:15 | 1670.77 | 0.00 | 0.00 | 0.00 | 43.54 | 12.97 | 406.15 | 274.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2025.75 | -382.39 |
F6 N1 APARTMENT | 21-DEC-13:15 | 1729.54 | 0.00 | 0.00 | 0.00 | 43.02 | 12.97 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -6.63 | 0.00 | -1954.83 | -212.55 |
F6 N2 APARTMENT | 21-DEC-13:15 | 1738.04 | 0.00 | 0.00 | 0.00 | 43.00 | 12.97 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -6.89 | 0.00 | -1954.84 | -220.77 |
F6 S1 APARTMENT | 07-MAR-05:00 | 269.50 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 392.53 | 0.00 | -838.46 | 0.00 | -256.37 | 0.00 |
F6 S2 APARTMENT | 07-MAR-05:00 | 272.53 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 389.36 | 0.00 | -838.32 | 0.00 | -256.37 | 0.00 |
F7 SW APARTMENT | 07-MAR-03:00 | 1057.02 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 402.54 | 0.00 | -1364.62 | 0.00 | -520.66 | 0.00 |
F7 NW APARTMENT | 25-JAN-10:55 | 1745.91 | 0.00 | 0.00 | 0.00 | 45.75 | 12.97 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -9.76 | 0.00 | -1852.75 | -348.26 |
F7 SE APARTMENT | 07-MAR-03:00 | 1068.36 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 389.87 | 0.00 | -1363.28 | 0.00 | -520.66 | 0.00 |
F7 NE APARTMENT | 06-FEB-12:15 | 1686.89 | 0.00 | 0.00 | 0.00 | 43.89 | 12.97 | 406.15 | 269.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2121.38 | -298.45 |
F7 N1 APARTMENT | 21-DEC-13:15 | 1699.11 | 0.00 | 0.00 | 0.00 | 43.29 | 12.97 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -7.72 | 0.00 | -2045.73 | -90.40 |
F7 N2 APARTMENT | 21-DEC-13:15 | 1701.73 | 0.00 | 0.00 | 0.00 | 43.27 | 12.97 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -7.96 | 0.00 | -2045.73 | -92.76 |
F7 S1 APARTMENT | 07-MAR-05:00 | 322.38 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 353.88 | 0.00 | -837.80 | 0.00 | -271.26 | 0.00 |
F7 S2 APARTMENT | 07-MAR-05:00 | 324.65 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 351.50 | 0.00 | -837.69 | 0.00 | -271.26 | 0.00 |
F8 SW APARTMENT | 07-MAR-03:00 | 1107.67 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 376.77 | 0.00 | -1363.59 | 0.00 | -546.56 | 0.00 |
F8 NW APARTMENT | 25-JAN-10:55 | 2009.08 | 0.00 | 0.00 | 0.00 | 45.95 | 12.97 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -11.72 | 0.00 | -1918.99 | -543.43 |
F8 SE APARTMENT | 07-MAR-03:00 | 1118.53 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 364.61 | 0.00 | -1362.29 | 0.00 | -546.56 | 0.00 |
F8 NE APARTMENT | 06-FEB-12:15 | 1710.24 | 0.00 | 0.00 | 0.00 | 44.18 | 12.97 | 406.15 | 265.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2209.81 | -229.28 |
F8 N1 APARTMENT | 25-JAN-10:55 | 1768.76 | 0.00 | 0.00 | 0.00 | 45.63 | 12.97 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -22.22 | 0.00 | -1788.24 | -423.06 |
F8 N2 APARTMENT | 25-JAN-10:55 | 1787.03 | 0.00 | 0.00 | 0.00 | 45.64 | 12.97 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -22.20 | 0.00 | -1787.90 | -441.69 |
F8 S1 APARTMENT | 07-MAR-03:00 | 380.51 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 361.79 | 0.00 | -838.34 | 0.00 | -329.67 | 0.00 |
F8 S2 APARTMENT | 07-MAR-03:00 | 382.85 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 359.33 | 0.00 | -838.23 | 0.00 | -329.67 | 0.00 |
F9 SW APARTMENT | 07-MAR-03:00 | 1228.25 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 273.02 | 0.00 | -1356.62 | 0.00 | -570.36 | 0.00 |
F9 NW APARTMENT | 06-FEB-12:10 | 2186.60 | 0.00 | 0.00 | 0.00 | 45.10 | 12.97 | 406.15 | 165.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2313.57 | -503.05 |
F9 SE APARTMENT | 07-MAR-03:00 | 1242.34 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 257.81 | 0.00 | -1355.50 | 0.00 | -570.36 | 0.00 |
F9 NE APARTMENT | 06-FEB-12:10 | 1923.00 | 0.00 | 0.00 | 0.00 | 44.58 | 12.97 | 406.15 | 266.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2325.70 | -327.03 |
F9 N1 APARTMENT | 25-JAN-10:55 | 2020.21 | 0.00 | 0.00 | 0.00 | 45.95 | 12.97 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -20.48 | 0.00 | -1845.01 | -619.78 |
F9 N2 APARTMENT | 25-JAN-10:55 | 2022.55 | 0.00 | 0.00 | 0.00 | 45.96 | 12.97 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -20.50 | 0.00 | -1844.99 | -622.13 |
F9 S1 APARTMENT | 07-MAR-03:00 | 503.96 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 247.60 | 0.00 | -833.25 | 0.00 | -344.03 | 0.00 |
F9 S2 APARTMENT | 07-MAR-03:00 | 505.65 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 245.79 | 0.00 | -833.13 | 0.00 | -344.03 | 0.00 |
T SW APARTMENT | 07-MAR-03:00 | 1644.45 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1325.27 | 0.00 | -592.43 | -152.46 |
T NW APARTMENT | 11-JAN-08:40 | 2436.96 | 0.00 | 0.00 | 0.00 | 72.00 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -308.89 | 0.00 | -2414.73 | -193.28 |
T SE APARTMENT | 07-MAR-03:00 | 1649.96 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1324.88 | 0.00 | -592.43 | -158.37 |
T NE APARTMENT | 06-FEB-12:15 | 1982.40 | 0.00 | 0.00 | 0.00 | 43.36 | 12.97 | 406.15 | 225.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2379.40 | -290.73 |
T N1 APARTMENT | 11-JAN-08:40 | 2298.28 | 0.00 | 0.00 | 0.00 | 70.55 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -205.90 | 0.00 | -2252.07 | -318.80 |
T N2 APARTMENT | 11-JAN-08:40 | 2317.42 | 0.00 | 0.00 | 0.00 | 70.60 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -205.36 | 0.00 | -2251.15 | -339.46 |
T S1 APARTMENT | 07-MAR-03:00 | 903.89 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -811.99 | 0.00 | -357.35 | -160.27 |
T S2 APARTMENT | 07-MAR-03:00 | 904.86 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -811.94 | 0.00 | -357.35 | -161.29 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 06-FEB-12:15 | 60814.94 | 0.00 | 0.00 | 0.00 | 3456.89 | 8844.29 | 32799.78 | 80961.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -164533.70 | -22343.68 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:36
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:36
Sec1.1A-General InformationData | |
Weather File | Phoenix Sky Harbor Intl Ap AZ USA TMY3 WMO#=722780 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 7836.48 |
Principal Heating Source | Electricity |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.50 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F2 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F3 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F4 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F6 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F7 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F8 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F9 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 7836.48 | 7059.89 | 776.58 |
Data | |
Number of hours heating loads not met | 11.25 |
Number of hours cooling loads not met | 362.25 |
Number of hours not met | 373.50 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 296.56 | 13120.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 162.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 8.14 | 0.00 | 7.22 | 57375.26 | 0.00 | 0.00 |
Space Cooling | 1085.41 | 90743.74 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 79.58 | 2563.97 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 44.12 | 3686.14 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 884.47 | 28046.48 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 0.00 | 0.00 | 855.99 | 73455.30 | 0.00 | 0.00 |
Receptacle Equipment | 1137.32 | 57042.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 3734.52 | 863.21 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 1137.32 | 3734.52 |
Natural Gas | 0.00 | 863.21 |
Additional | 0.00 | 0.00 |
Total | 1137.32 | 4597.73 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 37.84 |
Space Heating | 1.04 |
Space Cooling | 138.51 |
Fans-Interior | 112.87 |
Service Water Heating | 0.00 |
Receptacle Equipment | 145.13 |
Miscellaneous | 41.17 |
Subtotal | 476.56 |
Natural Gas [MJ/m2] | |
Space Heating | 0.92 |
Service Water Heating | 109.23 |
Miscellaneous | -0.00 |
Subtotal | 110.15 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 6.45 |
Space Heating | 0.33 |
Space Cooling | 23.61 |
Fans-Interior | 19.24 |
Service Water Heating | 18.62 |
Receptacle Equipment | 24.74 |
Miscellaneous | 7.02 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:36
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.330114 |
G NW APARTMENT DIRECT AIR | 0.322766 |
OFFICE DIRECT AIR | 0.433493 |
G NE APARTMENT DIRECT AIR | 0.270374 |
G N1 APARTMENT DIRECT AIR | 0.178087 |
G N2 APARTMENT DIRECT AIR | 0.177018 |
G S1 APARTMENT DIRECT AIR | 0.196515 |
G S2 APARTMENT DIRECT AIR | 0.202501 |
F2 SW APARTMENT DIRECT AIR | 0.381788 |
F2 NW APARTMENT DIRECT AIR | 0.373066 |
F2 SE APARTMENT DIRECT AIR | 0.360443 |
F2 NE APARTMENT DIRECT AIR | 0.316151 |
F2 N1 APARTMENT DIRECT AIR | 0.206184 |
F2 N2 APARTMENT DIRECT AIR | 0.205352 |
F2 S1 APARTMENT DIRECT AIR | 0.229405 |
F2 S2 APARTMENT DIRECT AIR | 0.231322 |
F3 SW APARTMENT DIRECT AIR | 0.384153 |
F3 NW APARTMENT DIRECT AIR | 0.375631 |
F3 SE APARTMENT DIRECT AIR | 0.343406 |
F3 NE APARTMENT DIRECT AIR | 0.320165 |
F3 N1 APARTMENT DIRECT AIR | 0.208948 |
F3 N2 APARTMENT DIRECT AIR | 0.208134 |
F3 S1 APARTMENT DIRECT AIR | 0.232068 |
F3 S2 APARTMENT DIRECT AIR | 0.232831 |
F4 SW APARTMENT DIRECT AIR | 0.387824 |
F4 NW APARTMENT DIRECT AIR | 0.379237 |
F4 SE APARTMENT DIRECT AIR | 0.345058 |
F4 NE APARTMENT DIRECT AIR | 0.323803 |
F4 N1 APARTMENT DIRECT AIR | 0.212169 |
F4 N2 APARTMENT DIRECT AIR | 0.211366 |
F4 S1 APARTMENT DIRECT AIR | 0.234932 |
F4 S2 APARTMENT DIRECT AIR | 0.235528 |
M SW APARTMENT DIRECT AIR | 0.393259 |
M NW APARTMENT DIRECT AIR | 0.384648 |
M SE APARTMENT DIRECT AIR | 0.350217 |
M NE APARTMENT DIRECT AIR | 0.329208 |
M N1 APARTMENT DIRECT AIR | 0.217126 |
M N2 APARTMENT DIRECT AIR | 0.216333 |
M S1 APARTMENT DIRECT AIR | 0.239569 |
M S2 APARTMENT DIRECT AIR | 0.240139 |
F6 SW APARTMENT DIRECT AIR | 0.392695 |
F6 NW APARTMENT DIRECT AIR | 0.383964 |
F6 SE APARTMENT DIRECT AIR | 0.349617 |
F6 NE APARTMENT DIRECT AIR | 0.328548 |
F6 N1 APARTMENT DIRECT AIR | 0.216199 |
F6 N2 APARTMENT DIRECT AIR | 0.215418 |
F6 S1 APARTMENT DIRECT AIR | 0.238500 |
F6 S2 APARTMENT DIRECT AIR | 0.239043 |
F7 SW APARTMENT DIRECT AIR | 0.393981 |
F7 NW APARTMENT DIRECT AIR | 0.385222 |
F7 SE APARTMENT DIRECT AIR | 0.350885 |
F7 NE APARTMENT DIRECT AIR | 0.329912 |
F7 N1 APARTMENT DIRECT AIR | 0.217185 |
F7 N2 APARTMENT DIRECT AIR | 0.216433 |
F7 S1 APARTMENT DIRECT AIR | 0.239306 |
F7 S2 APARTMENT DIRECT AIR | 0.239816 |
F8 SW APARTMENT DIRECT AIR | 0.396673 |
F8 NW APARTMENT DIRECT AIR | 0.387908 |
F8 SE APARTMENT DIRECT AIR | 0.353517 |
F8 NE APARTMENT DIRECT AIR | 0.332616 |
F8 N1 APARTMENT DIRECT AIR | 0.219624 |
F8 N2 APARTMENT DIRECT AIR | 0.218879 |
F8 S1 APARTMENT DIRECT AIR | 0.241510 |
F8 S2 APARTMENT DIRECT AIR | 0.242000 |
F9 SW APARTMENT DIRECT AIR | 0.410112 |
F9 NW APARTMENT DIRECT AIR | 0.401639 |
F9 SE APARTMENT DIRECT AIR | 0.362735 |
F9 NE APARTMENT DIRECT AIR | 0.341442 |
F9 N1 APARTMENT DIRECT AIR | 0.232090 |
F9 N2 APARTMENT DIRECT AIR | 0.231339 |
F9 S1 APARTMENT DIRECT AIR | 0.251511 |
F9 S2 APARTMENT DIRECT AIR | 0.252057 |
T SW APARTMENT DIRECT AIR | 0.498347 |
T NW APARTMENT DIRECT AIR | 0.483516 |
T SE APARTMENT DIRECT AIR | 0.446748 |
T NE APARTMENT DIRECT AIR | 0.411296 |
T N1 APARTMENT DIRECT AIR | 0.303663 |
T N2 APARTMENT DIRECT AIR | 0.303533 |
T S1 APARTMENT DIRECT AIR | 0.340092 |
T S2 APARTMENT DIRECT AIR | 0.340618 |
Maximum Flow Rate [m3/s] | |
AIRLOOP G SW MAIN BRANCH | 0.330114 |
AIRLOOP G NW MAIN BRANCH | 0.322766 |
AIRLOOP OFFICE MAIN BRANCH | 0.433493 |
AIRLOOP G NE MAIN BRANCH | 0.270374 |
AIRLOOP G N1 MAIN BRANCH | 0.178087 |
AIRLOOP G N2 MAIN BRANCH | 0.177018 |
AIRLOOP G S1 MAIN BRANCH | 0.196515 |
AIRLOOP G S2 MAIN BRANCH | 0.202501 |
AIRLOOP F2 SW MAIN BRANCH | 0.381788 |
AIRLOOP F2 NW MAIN BRANCH | 0.373066 |
AIRLOOP F2 SE MAIN BRANCH | 0.360443 |
AIRLOOP F2 NE MAIN BRANCH | 0.316151 |
AIRLOOP F2 N1 MAIN BRANCH | 0.206184 |
AIRLOOP F2 N2 MAIN BRANCH | 0.205352 |
AIRLOOP F2 S1 MAIN BRANCH | 0.229405 |
AIRLOOP F2 S2 MAIN BRANCH | 0.231322 |
AIRLOOP F3 SW MAIN BRANCH | 0.384153 |
AIRLOOP F3 NW MAIN BRANCH | 0.375631 |
AIRLOOP F3 SE MAIN BRANCH | 0.343406 |
AIRLOOP F3 NE MAIN BRANCH | 0.320165 |
AIRLOOP F3 N1 MAIN BRANCH | 0.208948 |
AIRLOOP F3 N2 MAIN BRANCH | 0.208134 |
AIRLOOP F3 S1 MAIN BRANCH | 0.232068 |
AIRLOOP F3 S2 MAIN BRANCH | 0.232831 |
AIRLOOP F4 SW MAIN BRANCH | 0.387824 |
AIRLOOP F4 NW MAIN BRANCH | 0.379237 |
AIRLOOP F4 SE MAIN BRANCH | 0.345058 |
AIRLOOP F4 NE MAIN BRANCH | 0.323803 |
AIRLOOP F4 N1 MAIN BRANCH | 0.212169 |
AIRLOOP F4 N2 MAIN BRANCH | 0.211366 |
AIRLOOP F4 S1 MAIN BRANCH | 0.234932 |
AIRLOOP F4 S2 MAIN BRANCH | 0.235528 |
AIRLOOP M SW MAIN BRANCH | 0.393259 |
AIRLOOP M NW MAIN BRANCH | 0.384648 |
AIRLOOP M SE MAIN BRANCH | 0.350217 |
AIRLOOP M NE MAIN BRANCH | 0.329208 |
AIRLOOP M N1 MAIN BRANCH | 0.217126 |
AIRLOOP M N2 MAIN BRANCH | 0.216333 |
AIRLOOP M S1 MAIN BRANCH | 0.239569 |
AIRLOOP M S2 MAIN BRANCH | 0.240139 |
AIRLOOP F6 SW MAIN BRANCH | 0.392695 |
AIRLOOP F6 NW MAIN BRANCH | 0.383964 |
AIRLOOP F6 SE MAIN BRANCH | 0.349617 |
AIRLOOP F6 NE MAIN BRANCH | 0.328548 |
AIRLOOP F6 N1 MAIN BRANCH | 0.216199 |
AIRLOOP F6 N2 MAIN BRANCH | 0.215418 |
AIRLOOP F6 S1 MAIN BRANCH | 0.238500 |
AIRLOOP F6 S2 MAIN BRANCH | 0.239043 |
AIRLOOP F7 SW MAIN BRANCH | 0.393981 |
AIRLOOP F7 NW MAIN BRANCH | 0.385222 |
AIRLOOP F7 SE MAIN BRANCH | 0.350885 |
AIRLOOP F7 NE MAIN BRANCH | 0.329912 |
AIRLOOP F7 N1 MAIN BRANCH | 0.217185 |
AIRLOOP F7 N2 MAIN BRANCH | 0.216433 |
AIRLOOP F7 S1 MAIN BRANCH | 0.239306 |
AIRLOOP F7 S2 MAIN BRANCH | 0.239816 |
AIRLOOP F8 SW MAIN BRANCH | 0.396673 |
AIRLOOP F8 NW MAIN BRANCH | 0.387908 |
AIRLOOP F8 SE MAIN BRANCH | 0.353517 |
AIRLOOP F8 NE MAIN BRANCH | 0.332616 |
AIRLOOP F8 N1 MAIN BRANCH | 0.219624 |
AIRLOOP F8 N2 MAIN BRANCH | 0.218879 |
AIRLOOP F8 S1 MAIN BRANCH | 0.241510 |
AIRLOOP F8 S2 MAIN BRANCH | 0.242000 |
AIRLOOP F9 SW MAIN BRANCH | 0.410112 |
AIRLOOP F9 NW MAIN BRANCH | 0.401639 |
AIRLOOP F9 SE MAIN BRANCH | 0.362735 |
AIRLOOP F9 NE MAIN BRANCH | 0.341442 |
AIRLOOP F9 N1 MAIN BRANCH | 0.232090 |
AIRLOOP F9 N2 MAIN BRANCH | 0.231339 |
AIRLOOP F9 S1 MAIN BRANCH | 0.251511 |
AIRLOOP F9 S2 MAIN BRANCH | 0.252057 |
AIRLOOP T SW MAIN BRANCH | 0.498347 |
AIRLOOP T NW MAIN BRANCH | 0.483516 |
AIRLOOP T SE MAIN BRANCH | 0.446748 |
AIRLOOP T NE MAIN BRANCH | 0.411296 |
AIRLOOP T N1 MAIN BRANCH | 0.303663 |
AIRLOOP T N2 MAIN BRANCH | 0.303533 |
AIRLOOP T S1 MAIN BRANCH | 0.340092 |
AIRLOOP T S2 MAIN BRANCH | 0.340618 |
Design Supply Air Flow Rate [m3/s] | |
AIRLOOP G SW | 0.330114 |
AIRLOOP G NW | 0.322766 |
AIRLOOP OFFICE | 0.433493 |
AIRLOOP G NE | 0.270374 |
AIRLOOP G N1 | 0.178087 |
AIRLOOP G N2 | 0.177018 |
AIRLOOP G S1 | 0.196515 |
AIRLOOP G S2 | 0.202501 |
AIRLOOP F2 SW | 0.381788 |
AIRLOOP F2 NW | 0.373066 |
AIRLOOP F2 SE | 0.360443 |
AIRLOOP F2 NE | 0.316151 |
AIRLOOP F2 N1 | 0.206184 |
AIRLOOP F2 N2 | 0.205352 |
AIRLOOP F2 S1 | 0.229405 |
AIRLOOP F2 S2 | 0.231322 |
AIRLOOP F3 SW | 0.384153 |
AIRLOOP F3 NW | 0.375631 |
AIRLOOP F3 SE | 0.343406 |
AIRLOOP F3 NE | 0.320165 |
AIRLOOP F3 N1 | 0.208948 |
AIRLOOP F3 N2 | 0.208134 |
AIRLOOP F3 S1 | 0.232068 |
AIRLOOP F3 S2 | 0.232831 |
AIRLOOP F4 SW | 0.387824 |
AIRLOOP F4 NW | 0.379237 |
AIRLOOP F4 SE | 0.345058 |
AIRLOOP F4 NE | 0.323803 |
AIRLOOP F4 N1 | 0.212169 |
AIRLOOP F4 N2 | 0.211366 |
AIRLOOP F4 S1 | 0.234932 |
AIRLOOP F4 S2 | 0.235528 |
AIRLOOP M SW | 0.393259 |
AIRLOOP M NW | 0.384648 |
AIRLOOP M SE | 0.350217 |
AIRLOOP M NE | 0.329208 |
AIRLOOP M N1 | 0.217126 |
AIRLOOP M N2 | 0.216333 |
AIRLOOP M S1 | 0.239569 |
AIRLOOP M S2 | 0.240139 |
AIRLOOP F6 SW | 0.392695 |
AIRLOOP F6 NW | 0.383964 |
AIRLOOP F6 SE | 0.349617 |
AIRLOOP F6 NE | 0.328548 |
AIRLOOP F6 N1 | 0.216199 |
AIRLOOP F6 N2 | 0.215418 |
AIRLOOP F6 S1 | 0.238500 |
AIRLOOP F6 S2 | 0.239043 |
AIRLOOP F7 SW | 0.393981 |
AIRLOOP F7 NW | 0.385222 |
AIRLOOP F7 SE | 0.350885 |
AIRLOOP F7 NE | 0.329912 |
AIRLOOP F7 N1 | 0.217185 |
AIRLOOP F7 N2 | 0.216433 |
AIRLOOP F7 S1 | 0.239306 |
AIRLOOP F7 S2 | 0.239816 |
AIRLOOP F8 SW | 0.396673 |
AIRLOOP F8 NW | 0.387908 |
AIRLOOP F8 SE | 0.353517 |
AIRLOOP F8 NE | 0.332616 |
AIRLOOP F8 N1 | 0.219624 |
AIRLOOP F8 N2 | 0.218879 |
AIRLOOP F8 S1 | 0.241510 |
AIRLOOP F8 S2 | 0.242000 |
AIRLOOP F9 SW | 0.410112 |
AIRLOOP F9 NW | 0.401639 |
AIRLOOP F9 SE | 0.362735 |
AIRLOOP F9 NE | 0.341442 |
AIRLOOP F9 N1 | 0.232090 |
AIRLOOP F9 N2 | 0.231339 |
AIRLOOP F9 S1 | 0.251511 |
AIRLOOP F9 S2 | 0.252057 |
AIRLOOP T SW | 0.498347 |
AIRLOOP T NW | 0.483516 |
AIRLOOP T SE | 0.446748 |
AIRLOOP T NE | 0.411296 |
AIRLOOP T N1 | 0.303663 |
AIRLOOP T N2 | 0.303533 |
AIRLOOP T S1 | 0.340092 |
AIRLOOP T S2 | 0.340618 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
AIRLOOP G SW OA CONTROLLER | 0.330114 | 0.025952 |
AIRLOOP G NW OA CONTROLLER | 0.322766 | 0.025952 |
AIRLOOP OFFICE OA CONTROLLER | 0.433493 | 0.038103 |
AIRLOOP G NE OA CONTROLLER | 0.270374 | 0.025952 |
AIRLOOP G N1 OA CONTROLLER | 0.178087 | 0.025952 |
AIRLOOP G N2 OA CONTROLLER | 0.177018 | 0.025952 |
AIRLOOP G S1 OA CONTROLLER | 0.196515 | 0.025952 |
AIRLOOP G S2 OA CONTROLLER | 0.202501 | 0.025952 |
AIRLOOP F2 SW OA CONTROLLER | 0.381788 | 0.025952 |
AIRLOOP F2 NW OA CONTROLLER | 0.373066 | 0.025952 |
AIRLOOP F2 SE OA CONTROLLER | 0.360443 | 0.025952 |
AIRLOOP F2 NE OA CONTROLLER | 0.316151 | 0.025952 |
AIRLOOP F2 N1 OA CONTROLLER | 0.206184 | 0.025952 |
AIRLOOP F2 N2 OA CONTROLLER | 0.205352 | 0.025952 |
AIRLOOP F2 S1 OA CONTROLLER | 0.229405 | 0.025952 |
AIRLOOP F2 S2 OA CONTROLLER | 0.231322 | 0.025952 |
AIRLOOP F3 SW OA CONTROLLER | 0.384153 | 0.025952 |
AIRLOOP F3 NW OA CONTROLLER | 0.375631 | 0.025952 |
AIRLOOP F3 SE OA CONTROLLER | 0.343406 | 0.025952 |
AIRLOOP F3 NE OA CONTROLLER | 0.320165 | 0.025952 |
AIRLOOP F3 N1 OA CONTROLLER | 0.208948 | 0.025952 |
AIRLOOP F3 N2 OA CONTROLLER | 0.208134 | 0.025952 |
AIRLOOP F3 S1 OA CONTROLLER | 0.232068 | 0.025952 |
AIRLOOP F3 S2 OA CONTROLLER | 0.232831 | 0.025952 |
AIRLOOP F4 SW OA CONTROLLER | 0.387824 | 0.025952 |
AIRLOOP F4 NW OA CONTROLLER | 0.379237 | 0.025952 |
AIRLOOP F4 SE OA CONTROLLER | 0.345058 | 0.025952 |
AIRLOOP F4 NE OA CONTROLLER | 0.323803 | 0.025952 |
AIRLOOP F4 N1 OA CONTROLLER | 0.212169 | 0.025952 |
AIRLOOP F4 N2 OA CONTROLLER | 0.211366 | 0.025952 |
AIRLOOP F4 S1 OA CONTROLLER | 0.234932 | 0.025952 |
AIRLOOP F4 S2 OA CONTROLLER | 0.235528 | 0.025952 |
AIRLOOP M SW OA CONTROLLER | 0.393259 | 0.025952 |
AIRLOOP M NW OA CONTROLLER | 0.384648 | 0.025952 |
AIRLOOP M SE OA CONTROLLER | 0.350217 | 0.025952 |
AIRLOOP M NE OA CONTROLLER | 0.329208 | 0.025952 |
AIRLOOP M N1 OA CONTROLLER | 0.217126 | 0.025952 |
AIRLOOP M N2 OA CONTROLLER | 0.216333 | 0.025952 |
AIRLOOP M S1 OA CONTROLLER | 0.239569 | 0.025952 |
AIRLOOP M S2 OA CONTROLLER | 0.240139 | 0.025952 |
AIRLOOP F6 SW OA CONTROLLER | 0.392695 | 0.025952 |
AIRLOOP F6 NW OA CONTROLLER | 0.383964 | 0.025952 |
AIRLOOP F6 SE OA CONTROLLER | 0.349617 | 0.025952 |
AIRLOOP F6 NE OA CONTROLLER | 0.328548 | 0.025952 |
AIRLOOP F6 N1 OA CONTROLLER | 0.216199 | 0.025952 |
AIRLOOP F6 N2 OA CONTROLLER | 0.215418 | 0.025952 |
AIRLOOP F6 S1 OA CONTROLLER | 0.238500 | 0.025952 |
AIRLOOP F6 S2 OA CONTROLLER | 0.239043 | 0.025952 |
AIRLOOP F7 SW OA CONTROLLER | 0.393981 | 0.025952 |
AIRLOOP F7 NW OA CONTROLLER | 0.385222 | 0.025952 |
AIRLOOP F7 SE OA CONTROLLER | 0.350885 | 0.025952 |
AIRLOOP F7 NE OA CONTROLLER | 0.329912 | 0.025952 |
AIRLOOP F7 N1 OA CONTROLLER | 0.217185 | 0.025952 |
AIRLOOP F7 N2 OA CONTROLLER | 0.216433 | 0.025952 |
AIRLOOP F7 S1 OA CONTROLLER | 0.239306 | 0.025952 |
AIRLOOP F7 S2 OA CONTROLLER | 0.239816 | 0.025952 |
AIRLOOP F8 SW OA CONTROLLER | 0.396673 | 0.025952 |
AIRLOOP F8 NW OA CONTROLLER | 0.387908 | 0.025952 |
AIRLOOP F8 SE OA CONTROLLER | 0.353517 | 0.025952 |
AIRLOOP F8 NE OA CONTROLLER | 0.332616 | 0.025952 |
AIRLOOP F8 N1 OA CONTROLLER | 0.219624 | 0.025952 |
AIRLOOP F8 N2 OA CONTROLLER | 0.218879 | 0.025952 |
AIRLOOP F8 S1 OA CONTROLLER | 0.241510 | 0.025952 |
AIRLOOP F8 S2 OA CONTROLLER | 0.242000 | 0.025952 |
AIRLOOP F9 SW OA CONTROLLER | 0.410112 | 0.025952 |
AIRLOOP F9 NW OA CONTROLLER | 0.401639 | 0.025952 |
AIRLOOP F9 SE OA CONTROLLER | 0.362735 | 0.025952 |
AIRLOOP F9 NE OA CONTROLLER | 0.341442 | 0.025952 |
AIRLOOP F9 N1 OA CONTROLLER | 0.232090 | 0.025952 |
AIRLOOP F9 N2 OA CONTROLLER | 0.231339 | 0.025952 |
AIRLOOP F9 S1 OA CONTROLLER | 0.251511 | 0.025952 |
AIRLOOP F9 S2 OA CONTROLLER | 0.252057 | 0.025952 |
AIRLOOP T SW OA CONTROLLER | 0.498347 | 0.025952 |
AIRLOOP T NW OA CONTROLLER | 0.483516 | 0.025952 |
AIRLOOP T SE OA CONTROLLER | 0.446748 | 0.025952 |
AIRLOOP T NE OA CONTROLLER | 0.411296 | 0.025952 |
AIRLOOP T N1 OA CONTROLLER | 0.303663 | 0.025952 |
AIRLOOP T N2 OA CONTROLLER | 0.303533 | 0.025952 |
AIRLOOP T S1 OA CONTROLLER | 0.340092 | 0.025952 |
AIRLOOP T S2 OA CONTROLLER | 0.340618 | 0.025952 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity [W] | Rated Sensible Cooling Capacity [W] | Rated Water Flow Rate [m3/s] | |
HEAT PUMP COOLING MODE AIRLOOP G SW | 0.330114 | 4944.70 | 3594.30 | 0.000108 |
HEAT PUMP COOLING MODE AIRLOOP G NW | 0.322766 | 4819.86 | 3505.73 | 0.000105 |
HEAT PUMP COOLING MODE AIRLOOP OFFICE | 0.433493 | 6484.99 | 4721.09 | 0.000142 |
HEAT PUMP COOLING MODE AIRLOOP G NE | 0.270374 | 4053.52 | 2947.75 | 0.000089 |
HEAT PUMP COOLING MODE AIRLOOP G N1 | 0.178087 | 2825.99 | 2004.98 | 0.000062 |
HEAT PUMP COOLING MODE AIRLOOP G N2 | 0.177018 | 2811.26 | 1993.91 | 0.000061 |
HEAT PUMP COOLING MODE AIRLOOP G S1 | 0.196515 | 3153.41 | 2230.14 | 0.000069 |
HEAT PUMP COOLING MODE AIRLOOP G S2 | 0.202501 | 3235.37 | 2292.13 | 0.000071 |
HEAT PUMP COOLING MODE AIRLOOP F2 SW | 0.381788 | 5631.45 | 4118.89 | 0.000123 |
HEAT PUMP COOLING MODE AIRLOOP F2 NW | 0.373066 | 5494.17 | 4018.91 | 0.000120 |
HEAT PUMP COOLING MODE AIRLOOP F2 SE | 0.360443 | 5311.55 | 3887.58 | 0.000116 |
HEAT PUMP COOLING MODE AIRLOOP F2 NE | 0.316151 | 4678.02 | 3420.19 | 0.000102 |
HEAT PUMP COOLING MODE AIRLOOP F2 N1 | 0.206184 | 3207.74 | 2296.47 | 0.000070 |
HEAT PUMP COOLING MODE AIRLOOP F2 N2 | 0.205352 | 3196.33 | 2287.88 | 0.000070 |
HEAT PUMP COOLING MODE AIRLOOP F2 S1 | 0.229405 | 3596.21 | 2568.45 | 0.000079 |
HEAT PUMP COOLING MODE AIRLOOP F2 S2 | 0.231322 | 3622.42 | 2588.24 | 0.000079 |
HEAT PUMP COOLING MODE AIRLOOP F3 SW | 0.384153 | 5656.23 | 4141.34 | 0.000124 |
HEAT PUMP COOLING MODE AIRLOOP F3 NW | 0.375631 | 5521.67 | 4043.39 | 0.000121 |
HEAT PUMP COOLING MODE AIRLOOP F3 SE | 0.343406 | 5071.97 | 3711.05 | 0.000111 |
HEAT PUMP COOLING MODE AIRLOOP F3 NE | 0.320165 | 4725.41 | 3459.59 | 0.000103 |
HEAT PUMP COOLING MODE AIRLOOP F3 N1 | 0.208948 | 3241.26 | 2323.92 | 0.000071 |
HEAT PUMP COOLING MODE AIRLOOP F3 N2 | 0.208134 | 3230.10 | 2315.52 | 0.000071 |
HEAT PUMP COOLING MODE AIRLOOP F3 S1 | 0.232068 | 3628.31 | 2594.88 | 0.000079 |
HEAT PUMP COOLING MODE AIRLOOP F3 S2 | 0.232831 | 3638.75 | 2602.76 | 0.000079 |
HEAT PUMP COOLING MODE AIRLOOP F4 SW | 0.387824 | 5700.68 | 4177.63 | 0.000125 |
HEAT PUMP COOLING MODE AIRLOOP F4 NW | 0.379237 | 5565.27 | 4079.01 | 0.000122 |
HEAT PUMP COOLING MODE AIRLOOP F4 SE | 0.345058 | 5089.00 | 3726.67 | 0.000111 |
HEAT PUMP COOLING MODE AIRLOOP F4 NE | 0.323803 | 4769.53 | 3495.59 | 0.000104 |
HEAT PUMP COOLING MODE AIRLOOP F4 N1 | 0.212169 | 3282.13 | 2356.35 | 0.000072 |
HEAT PUMP COOLING MODE AIRLOOP F4 N2 | 0.211366 | 3271.14 | 2348.07 | 0.000071 |
HEAT PUMP COOLING MODE AIRLOOP F4 S1 | 0.234932 | 3664.24 | 2623.66 | 0.000080 |
HEAT PUMP COOLING MODE AIRLOOP F4 S2 | 0.235528 | 3672.38 | 2629.80 | 0.000080 |
HEAT PUMP COOLING MODE AIRLOOP M SW | 0.393259 | 5775.51 | 4234.89 | 0.000126 |
HEAT PUMP COOLING MODE AIRLOOP M NW | 0.384648 | 5636.05 | 4135.48 | 0.000123 |
HEAT PUMP COOLING MODE AIRLOOP M SE | 0.350217 | 5154.81 | 3778.50 | 0.000113 |
HEAT PUMP COOLING MODE AIRLOOP M NE | 0.329208 | 4838.72 | 3549.95 | 0.000106 |
HEAT PUMP COOLING MODE AIRLOOP M N1 | 0.217126 | 3347.39 | 2406.82 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP M N2 | 0.216333 | 3336.53 | 2398.65 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP M S1 | 0.239569 | 3724.95 | 2670.84 | 0.000081 |
HEAT PUMP COOLING MODE AIRLOOP M S2 | 0.240139 | 3732.74 | 2676.72 | 0.000082 |
HEAT PUMP COOLING MODE AIRLOOP F6 SW | 0.392695 | 5763.95 | 4228.17 | 0.000126 |
HEAT PUMP COOLING MODE AIRLOOP F6 NW | 0.383964 | 5622.84 | 4127.52 | 0.000123 |
HEAT PUMP COOLING MODE AIRLOOP F6 SE | 0.349617 | 5142.86 | 3771.43 | 0.000112 |
HEAT PUMP COOLING MODE AIRLOOP F6 NE | 0.328548 | 4825.97 | 3542.27 | 0.000105 |
HEAT PUMP COOLING MODE AIRLOOP F6 N1 | 0.216199 | 3332.42 | 2396.71 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F6 N2 | 0.215418 | 3321.73 | 2388.66 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F6 S1 | 0.238500 | 3712.36 | 2661.02 | 0.000081 |
HEAT PUMP COOLING MODE AIRLOOP F6 S2 | 0.239043 | 3715.54 | 2664.88 | 0.000081 |
HEAT PUMP COOLING MODE AIRLOOP F7 SW | 0.393981 | 5778.07 | 4240.53 | 0.000126 |
HEAT PUMP COOLING MODE AIRLOOP F7 NW | 0.385222 | 5636.58 | 4139.60 | 0.000123 |
HEAT PUMP COOLING MODE AIRLOOP F7 SE | 0.350885 | 5156.79 | 3783.62 | 0.000113 |
HEAT PUMP COOLING MODE AIRLOOP F7 NE | 0.329912 | 4854.16 | 3561.09 | 0.000106 |
HEAT PUMP COOLING MODE AIRLOOP F7 N1 | 0.217185 | 3352.76 | 2410.75 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F7 N2 | 0.216433 | 3342.47 | 2402.99 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F7 S1 | 0.239306 | 3721.41 | 2668.85 | 0.000081 |
HEAT PUMP COOLING MODE AIRLOOP F7 S2 | 0.239816 | 3724.14 | 2672.37 | 0.000081 |
HEAT PUMP COOLING MODE AIRLOOP F8 SW | 0.396673 | 5811.70 | 4267.40 | 0.000127 |
HEAT PUMP COOLING MODE AIRLOOP F8 NW | 0.387908 | 5670.12 | 4166.39 | 0.000124 |
HEAT PUMP COOLING MODE AIRLOOP F8 SE | 0.353517 | 5189.65 | 3809.90 | 0.000113 |
HEAT PUMP COOLING MODE AIRLOOP F8 NE | 0.332616 | 4888.03 | 3588.11 | 0.000107 |
HEAT PUMP COOLING MODE AIRLOOP F8 N1 | 0.219624 | 3384.35 | 2435.45 | 0.000074 |
HEAT PUMP COOLING MODE AIRLOOP F8 N2 | 0.218879 | 3374.18 | 2427.78 | 0.000074 |
HEAT PUMP COOLING MODE AIRLOOP F8 S1 | 0.241510 | 3749.74 | 2691.16 | 0.000082 |
HEAT PUMP COOLING MODE AIRLOOP F8 S2 | 0.242000 | 3756.44 | 2696.21 | 0.000082 |
HEAT PUMP COOLING MODE AIRLOOP F9 SW | 0.410112 | 5986.62 | 4401.83 | 0.000131 |
HEAT PUMP COOLING MODE AIRLOOP F9 NW | 0.401639 | 5854.40 | 4306.46 | 0.000128 |
HEAT PUMP COOLING MODE AIRLOOP F9 SE | 0.362735 | 5321.03 | 3907.51 | 0.000116 |
HEAT PUMP COOLING MODE AIRLOOP F9 NE | 0.341442 | 5005.45 | 3677.95 | 0.000109 |
HEAT PUMP COOLING MODE AIRLOOP F9 N1 | 0.232090 | 3544.48 | 2559.13 | 0.000077 |
HEAT PUMP COOLING MODE AIRLOOP F9 N2 | 0.231339 | 3542.93 | 2555.77 | 0.000077 |
HEAT PUMP COOLING MODE AIRLOOP F9 S1 | 0.251511 | 3884.62 | 2793.86 | 0.000085 |
HEAT PUMP COOLING MODE AIRLOOP F9 S2 | 0.252057 | 3892.07 | 2799.47 | 0.000085 |
HEAT PUMP COOLING MODE AIRLOOP T SW | 0.498347 | 7202.93 | 5313.14 | 0.000157 |
HEAT PUMP COOLING MODE AIRLOOP T NW | 0.483516 | 6988.79 | 5155.84 | 0.000153 |
HEAT PUMP COOLING MODE AIRLOOP T SE | 0.446748 | 6515.69 | 4791.43 | 0.000142 |
HEAT PUMP COOLING MODE AIRLOOP T NE | 0.411296 | 5962.26 | 4396.91 | 0.000130 |
HEAT PUMP COOLING MODE AIRLOOP T N1 | 0.303663 | 4594.55 | 3330.19 | 0.000100 |
HEAT PUMP COOLING MODE AIRLOOP T N2 | 0.303533 | 4592.76 | 3328.85 | 0.000100 |
HEAT PUMP COOLING MODE AIRLOOP T S1 | 0.340092 | 5091.20 | 3704.44 | 0.000111 |
HEAT PUMP COOLING MODE AIRLOOP T S2 | 0.340618 | 5098.39 | 3709.85 | 0.000111 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Supplemental Heating Coil Nominal Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
AIRLOOP G SW DXAC HEAT PUMP | 0.330114 | 0.330114 | 0.330114 | 0.330114 | 4944.70 | 4944.70 | 1814.94 | 1.00 |
AIRLOOP G NW DXAC HEAT PUMP | 0.322766 | 0.322766 | 0.322766 | 0.322766 | 4819.86 | 4819.86 | 1816.25 | 1.00 |
AIRLOOP OFFICE DXAC HEAT PUMP | 0.433493 | 0.433493 | 0.433493 | 0.433493 | 6484.99 | 6484.99 | 2375.90 | 1.00 |
AIRLOOP G NE DXAC HEAT PUMP | 0.270374 | 0.270374 | 0.270374 | 0.270374 | 4053.52 | 4053.52 | 1811.69 | 1.00 |
AIRLOOP G N1 DXAC HEAT PUMP | 0.178087 | 0.178087 | 0.178087 | 0.178087 | 2825.99 | 2825.99 | 1282.95 | 1.00 |
AIRLOOP G N2 DXAC HEAT PUMP | 0.177018 | 0.177018 | 0.177018 | 0.177018 | 2811.26 | 2811.26 | 1282.88 | 1.00 |
AIRLOOP G S1 DXAC HEAT PUMP | 0.196515 | 0.196515 | 0.196515 | 0.196515 | 3153.41 | 3153.41 | 1279.12 | 1.00 |
AIRLOOP G S2 DXAC HEAT PUMP | 0.202501 | 0.202501 | 0.202501 | 0.202501 | 3235.37 | 3235.37 | 1285.25 | 1.00 |
AIRLOOP F2 SW DXAC HEAT PUMP | 0.381788 | 0.381788 | 0.381788 | 0.381788 | 5631.45 | 5631.45 | 1769.67 | 1.00 |
AIRLOOP F2 NW DXAC HEAT PUMP | 0.373066 | 0.373066 | 0.373066 | 0.373066 | 5494.17 | 5494.17 | 1770.54 | 1.00 |
AIRLOOP F2 SE DXAC HEAT PUMP | 0.360443 | 0.360443 | 0.360443 | 0.360443 | 5311.55 | 5311.55 | 1784.02 | 1.00 |
AIRLOOP F2 NE DXAC HEAT PUMP | 0.316151 | 0.316151 | 0.316151 | 0.316151 | 4678.02 | 4678.02 | 1765.38 | 1.00 |
AIRLOOP F2 N1 DXAC HEAT PUMP | 0.206184 | 0.206184 | 0.206184 | 0.206184 | 3207.74 | 3207.74 | 1140.24 | 1.00 |
AIRLOOP F2 N2 DXAC HEAT PUMP | 0.205352 | 0.205352 | 0.205352 | 0.205352 | 3196.33 | 3196.33 | 1140.15 | 1.00 |
AIRLOOP F2 S1 DXAC HEAT PUMP | 0.229405 | 0.229405 | 0.229405 | 0.229405 | 3596.21 | 3596.21 | 1142.10 | 1.00 |
AIRLOOP F2 S2 DXAC HEAT PUMP | 0.231322 | 0.231322 | 0.231322 | 0.231322 | 3622.42 | 3622.42 | 1143.42 | 1.00 |
AIRLOOP F3 SW DXAC HEAT PUMP | 0.384153 | 0.384153 | 0.384153 | 0.384153 | 5656.23 | 5656.23 | 1753.45 | 1.00 |
AIRLOOP F3 NW DXAC HEAT PUMP | 0.375631 | 0.375631 | 0.375631 | 0.375631 | 5521.67 | 5521.67 | 1754.10 | 1.00 |
AIRLOOP F3 SE DXAC HEAT PUMP | 0.343406 | 0.343406 | 0.343406 | 0.343406 | 5071.97 | 5071.97 | 1750.98 | 1.00 |
AIRLOOP F3 NE DXAC HEAT PUMP | 0.320165 | 0.320165 | 0.320165 | 0.320165 | 4725.41 | 4725.41 | 1749.20 | 1.00 |
AIRLOOP F3 N1 DXAC HEAT PUMP | 0.208948 | 0.208948 | 0.208948 | 0.208948 | 3241.26 | 3241.26 | 1105.96 | 1.00 |
AIRLOOP F3 N2 DXAC HEAT PUMP | 0.208134 | 0.208134 | 0.208134 | 0.208134 | 3230.10 | 3230.10 | 1105.87 | 1.00 |
AIRLOOP F3 S1 DXAC HEAT PUMP | 0.232068 | 0.232068 | 0.232068 | 0.232068 | 3628.31 | 3628.31 | 1105.89 | 1.00 |
AIRLOOP F3 S2 DXAC HEAT PUMP | 0.232831 | 0.232831 | 0.232831 | 0.232831 | 3638.75 | 3638.75 | 1106.06 | 1.00 |
AIRLOOP F4 SW DXAC HEAT PUMP | 0.387824 | 0.387824 | 0.387824 | 0.387824 | 5700.68 | 5700.68 | 1768.71 | 1.00 |
AIRLOOP F4 NW DXAC HEAT PUMP | 0.379237 | 0.379237 | 0.379237 | 0.379237 | 5565.27 | 5565.27 | 1769.66 | 1.00 |
AIRLOOP F4 SE DXAC HEAT PUMP | 0.345058 | 0.345058 | 0.345058 | 0.345058 | 5089.00 | 5089.00 | 1764.45 | 1.00 |
AIRLOOP F4 NE DXAC HEAT PUMP | 0.323803 | 0.323803 | 0.323803 | 0.323803 | 4769.53 | 4769.53 | 1765.11 | 1.00 |
AIRLOOP F4 N1 DXAC HEAT PUMP | 0.212169 | 0.212169 | 0.212169 | 0.212169 | 3282.13 | 3282.13 | 1107.04 | 1.00 |
AIRLOOP F4 N2 DXAC HEAT PUMP | 0.211366 | 0.211366 | 0.211366 | 0.211366 | 3271.14 | 3271.14 | 1106.96 | 1.00 |
AIRLOOP F4 S1 DXAC HEAT PUMP | 0.234932 | 0.234932 | 0.234932 | 0.234932 | 3664.24 | 3664.24 | 1106.41 | 1.00 |
AIRLOOP F4 S2 DXAC HEAT PUMP | 0.235528 | 0.235528 | 0.235528 | 0.235528 | 3672.38 | 3672.38 | 1106.36 | 1.00 |
AIRLOOP M SW DXAC HEAT PUMP | 0.393259 | 0.393259 | 0.393259 | 0.393259 | 5775.51 | 5775.51 | 1768.36 | 1.00 |
AIRLOOP M NW DXAC HEAT PUMP | 0.384648 | 0.384648 | 0.384648 | 0.384648 | 5636.05 | 5636.05 | 1768.46 | 1.00 |
AIRLOOP M SE DXAC HEAT PUMP | 0.350217 | 0.350217 | 0.350217 | 0.350217 | 5154.81 | 5154.81 | 1764.22 | 1.00 |
AIRLOOP M NE DXAC HEAT PUMP | 0.329208 | 0.329208 | 0.329208 | 0.329208 | 4838.72 | 4838.72 | 1764.28 | 1.00 |
AIRLOOP M N1 DXAC HEAT PUMP | 0.217126 | 0.217126 | 0.217126 | 0.217126 | 3347.39 | 3347.39 | 1097.31 | 1.00 |
AIRLOOP M N2 DXAC HEAT PUMP | 0.216333 | 0.216333 | 0.216333 | 0.216333 | 3336.53 | 3336.53 | 1097.23 | 1.00 |
AIRLOOP M S1 DXAC HEAT PUMP | 0.239569 | 0.239569 | 0.239569 | 0.239569 | 3724.95 | 3724.95 | 1097.45 | 1.00 |
AIRLOOP M S2 DXAC HEAT PUMP | 0.240139 | 0.240139 | 0.240139 | 0.240139 | 3732.74 | 3732.74 | 1097.38 | 1.00 |
AIRLOOP F6 SW DXAC HEAT PUMP | 0.392695 | 0.392695 | 0.392695 | 0.392695 | 5763.95 | 5763.95 | 1825.51 | 1.00 |
AIRLOOP F6 NW DXAC HEAT PUMP | 0.383964 | 0.383964 | 0.383964 | 0.383964 | 5622.84 | 5622.84 | 1826.44 | 1.00 |
AIRLOOP F6 SE DXAC HEAT PUMP | 0.349617 | 0.349617 | 0.349617 | 0.349617 | 5142.86 | 5142.86 | 1821.69 | 1.00 |
AIRLOOP F6 NE DXAC HEAT PUMP | 0.328548 | 0.328548 | 0.328548 | 0.328548 | 4825.97 | 4825.97 | 1822.62 | 1.00 |
AIRLOOP F6 N1 DXAC HEAT PUMP | 0.216199 | 0.216199 | 0.216199 | 0.216199 | 3332.42 | 3332.42 | 1141.72 | 1.00 |
AIRLOOP F6 N2 DXAC HEAT PUMP | 0.215418 | 0.215418 | 0.215418 | 0.215418 | 3321.73 | 3321.73 | 1141.65 | 1.00 |
AIRLOOP F6 S1 DXAC HEAT PUMP | 0.238500 | 0.238500 | 0.238500 | 0.238500 | 3712.36 | 3712.36 | 1141.01 | 1.00 |
AIRLOOP F6 S2 DXAC HEAT PUMP | 0.239043 | 0.239043 | 0.239043 | 0.239043 | 3715.54 | 3715.54 | 1140.95 | 1.00 |
AIRLOOP F7 SW DXAC HEAT PUMP | 0.393981 | 0.393981 | 0.393981 | 0.393981 | 5778.07 | 5778.07 | 1861.44 | 1.00 |
AIRLOOP F7 NW DXAC HEAT PUMP | 0.385222 | 0.385222 | 0.385222 | 0.385222 | 5636.58 | 5636.58 | 1862.16 | 1.00 |
AIRLOOP F7 SE DXAC HEAT PUMP | 0.350885 | 0.350885 | 0.350885 | 0.350885 | 5156.79 | 5156.79 | 1857.98 | 1.00 |
AIRLOOP F7 NE DXAC HEAT PUMP | 0.329912 | 0.329912 | 0.329912 | 0.329912 | 4854.16 | 4854.16 | 1858.69 | 1.00 |
AIRLOOP F7 N1 DXAC HEAT PUMP | 0.217185 | 0.217185 | 0.217185 | 0.217185 | 3352.76 | 3352.76 | 1168.49 | 1.00 |
AIRLOOP F7 N2 DXAC HEAT PUMP | 0.216433 | 0.216433 | 0.216433 | 0.216433 | 3342.47 | 3342.47 | 1168.43 | 1.00 |
AIRLOOP F7 S1 DXAC HEAT PUMP | 0.239306 | 0.239306 | 0.239306 | 0.239306 | 3721.41 | 3721.41 | 1167.96 | 1.00 |
AIRLOOP F7 S2 DXAC HEAT PUMP | 0.239816 | 0.239816 | 0.239816 | 0.239816 | 3724.14 | 3724.14 | 1167.90 | 1.00 |
AIRLOOP F8 SW DXAC HEAT PUMP | 0.396673 | 0.396673 | 0.396673 | 0.396673 | 5811.70 | 5811.70 | 1900.21 | 1.00 |
AIRLOOP F8 NW DXAC HEAT PUMP | 0.387908 | 0.387908 | 0.387908 | 0.387908 | 5670.12 | 5670.12 | 1900.58 | 1.00 |
AIRLOOP F8 SE DXAC HEAT PUMP | 0.353517 | 0.353517 | 0.353517 | 0.353517 | 5189.65 | 5189.65 | 1897.08 | 1.00 |
AIRLOOP F8 NE DXAC HEAT PUMP | 0.332616 | 0.332616 | 0.332616 | 0.332616 | 4888.03 | 4888.03 | 1897.46 | 1.00 |
AIRLOOP F8 N1 DXAC HEAT PUMP | 0.219624 | 0.219624 | 0.219624 | 0.219624 | 3384.35 | 3384.35 | 1199.32 | 1.00 |
AIRLOOP F8 N2 DXAC HEAT PUMP | 0.218879 | 0.218879 | 0.218879 | 0.218879 | 3374.18 | 3374.18 | 1199.26 | 1.00 |
AIRLOOP F8 S1 DXAC HEAT PUMP | 0.241510 | 0.241510 | 0.241510 | 0.241510 | 3749.74 | 3749.74 | 1199.11 | 1.00 |
AIRLOOP F8 S2 DXAC HEAT PUMP | 0.242000 | 0.242000 | 0.242000 | 0.242000 | 3756.44 | 3756.44 | 1199.05 | 1.00 |
AIRLOOP F9 SW DXAC HEAT PUMP | 0.410112 | 0.410112 | 0.410112 | 0.410112 | 5986.62 | 5986.62 | 2022.47 | 1.00 |
AIRLOOP F9 NW DXAC HEAT PUMP | 0.401639 | 0.401639 | 0.401639 | 0.401639 | 5854.40 | 5854.40 | 2021.10 | 1.00 |
AIRLOOP F9 SE DXAC HEAT PUMP | 0.362735 | 0.362735 | 0.362735 | 0.362735 | 5321.03 | 5321.03 | 2019.65 | 1.00 |
AIRLOOP F9 NE DXAC HEAT PUMP | 0.341442 | 0.341442 | 0.341442 | 0.341442 | 5005.45 | 5005.45 | 2018.28 | 1.00 |
AIRLOOP F9 N1 DXAC HEAT PUMP | 0.232090 | 0.232090 | 0.232090 | 0.232090 | 3544.48 | 3544.48 | 1307.00 | 1.00 |
AIRLOOP F9 N2 DXAC HEAT PUMP | 0.231339 | 0.231339 | 0.231339 | 0.231339 | 3542.93 | 3542.93 | 1306.95 | 1.00 |
AIRLOOP F9 S1 DXAC HEAT PUMP | 0.251511 | 0.251511 | 0.251511 | 0.251511 | 3884.62 | 3884.62 | 1308.28 | 1.00 |
AIRLOOP F9 S2 DXAC HEAT PUMP | 0.252057 | 0.252057 | 0.252057 | 0.252057 | 3892.07 | 3892.07 | 1308.23 | 1.00 |
AIRLOOP T SW DXAC HEAT PUMP | 0.498347 | 0.498347 | 0.498347 | 0.498347 | 7202.93 | 7202.93 | 2441.16 | 1.00 |
AIRLOOP T NW DXAC HEAT PUMP | 0.483516 | 0.483516 | 0.483516 | 0.483516 | 6988.79 | 6988.79 | 2443.61 | 1.00 |
AIRLOOP T SE DXAC HEAT PUMP | 0.446748 | 0.446748 | 0.446748 | 0.446748 | 6515.69 | 6515.69 | 2438.78 | 1.00 |
AIRLOOP T NE DXAC HEAT PUMP | 0.411296 | 0.411296 | 0.411296 | 0.411296 | 5962.26 | 5962.26 | 2441.23 | 1.00 |
AIRLOOP T N1 DXAC HEAT PUMP | 0.303663 | 0.303663 | 0.303663 | 0.303663 | 4594.55 | 4594.55 | 1757.79 | 1.00 |
AIRLOOP T N2 DXAC HEAT PUMP | 0.303533 | 0.303533 | 0.303533 | 0.303533 | 4592.76 | 4592.76 | 1757.74 | 1.00 |
AIRLOOP T S1 DXAC HEAT PUMP | 0.340092 | 0.340092 | 0.340092 | 0.340092 | 5091.20 | 5091.20 | 1754.39 | 1.00 |
AIRLOOP T S2 DXAC HEAT PUMP | 0.340618 | 0.340618 | 0.340618 | 0.340618 | 5098.39 | 5098.39 | 1754.35 | 1.00 |
Maximum Flow Rate [m3/s] | |
AIRLOOP G SW SUPPLY FAN | 0.330114 |
AIRLOOP G NW SUPPLY FAN | 0.322766 |
AIRLOOP OFFICE SUPPLY FAN | 0.433493 |
AIRLOOP G NE SUPPLY FAN | 0.270374 |
AIRLOOP G N1 SUPPLY FAN | 0.178087 |
AIRLOOP G N2 SUPPLY FAN | 0.177018 |
AIRLOOP G S1 SUPPLY FAN | 0.196515 |
AIRLOOP G S2 SUPPLY FAN | 0.202501 |
AIRLOOP F2 SW SUPPLY FAN | 0.381788 |
AIRLOOP F2 NW SUPPLY FAN | 0.373066 |
AIRLOOP F2 SE SUPPLY FAN | 0.360443 |
AIRLOOP F2 NE SUPPLY FAN | 0.316151 |
AIRLOOP F2 N1 SUPPLY FAN | 0.206184 |
AIRLOOP F2 N2 SUPPLY FAN | 0.205352 |
AIRLOOP F2 S1 SUPPLY FAN | 0.229405 |
AIRLOOP F2 S2 SUPPLY FAN | 0.231322 |
AIRLOOP F3 SW SUPPLY FAN | 0.384153 |
AIRLOOP F3 NW SUPPLY FAN | 0.375631 |
AIRLOOP F3 SE SUPPLY FAN | 0.343406 |
AIRLOOP F3 NE SUPPLY FAN | 0.320165 |
AIRLOOP F3 N1 SUPPLY FAN | 0.208948 |
AIRLOOP F3 N2 SUPPLY FAN | 0.208134 |
AIRLOOP F3 S1 SUPPLY FAN | 0.232068 |
AIRLOOP F3 S2 SUPPLY FAN | 0.232831 |
AIRLOOP F4 SW SUPPLY FAN | 0.387824 |
AIRLOOP F4 NW SUPPLY FAN | 0.379237 |
AIRLOOP F4 SE SUPPLY FAN | 0.345058 |
AIRLOOP F4 NE SUPPLY FAN | 0.323803 |
AIRLOOP F4 N1 SUPPLY FAN | 0.212169 |
AIRLOOP F4 N2 SUPPLY FAN | 0.211366 |
AIRLOOP F4 S1 SUPPLY FAN | 0.234932 |
AIRLOOP F4 S2 SUPPLY FAN | 0.235528 |
AIRLOOP M SW SUPPLY FAN | 0.393259 |
AIRLOOP M NW SUPPLY FAN | 0.384648 |
AIRLOOP M SE SUPPLY FAN | 0.350217 |
AIRLOOP M NE SUPPLY FAN | 0.329208 |
AIRLOOP M N1 SUPPLY FAN | 0.217126 |
AIRLOOP M N2 SUPPLY FAN | 0.216333 |
AIRLOOP M S1 SUPPLY FAN | 0.239569 |
AIRLOOP M S2 SUPPLY FAN | 0.240139 |
AIRLOOP F6 SW SUPPLY FAN | 0.392695 |
AIRLOOP F6 NW SUPPLY FAN | 0.383964 |
AIRLOOP F6 SE SUPPLY FAN | 0.349617 |
AIRLOOP F6 NE SUPPLY FAN | 0.328548 |
AIRLOOP F6 N1 SUPPLY FAN | 0.216199 |
AIRLOOP F6 N2 SUPPLY FAN | 0.215418 |
AIRLOOP F6 S1 SUPPLY FAN | 0.238500 |
AIRLOOP F6 S2 SUPPLY FAN | 0.239043 |
AIRLOOP F7 SW SUPPLY FAN | 0.393981 |
AIRLOOP F7 NW SUPPLY FAN | 0.385222 |
AIRLOOP F7 SE SUPPLY FAN | 0.350885 |
AIRLOOP F7 NE SUPPLY FAN | 0.329912 |
AIRLOOP F7 N1 SUPPLY FAN | 0.217185 |
AIRLOOP F7 N2 SUPPLY FAN | 0.216433 |
AIRLOOP F7 S1 SUPPLY FAN | 0.239306 |
AIRLOOP F7 S2 SUPPLY FAN | 0.239816 |
AIRLOOP F8 SW SUPPLY FAN | 0.396673 |
AIRLOOP F8 NW SUPPLY FAN | 0.387908 |
AIRLOOP F8 SE SUPPLY FAN | 0.353517 |
AIRLOOP F8 NE SUPPLY FAN | 0.332616 |
AIRLOOP F8 N1 SUPPLY FAN | 0.219624 |
AIRLOOP F8 N2 SUPPLY FAN | 0.218879 |
AIRLOOP F8 S1 SUPPLY FAN | 0.241510 |
AIRLOOP F8 S2 SUPPLY FAN | 0.242000 |
AIRLOOP F9 SW SUPPLY FAN | 0.410112 |
AIRLOOP F9 NW SUPPLY FAN | 0.401639 |
AIRLOOP F9 SE SUPPLY FAN | 0.362735 |
AIRLOOP F9 NE SUPPLY FAN | 0.341442 |
AIRLOOP F9 N1 SUPPLY FAN | 0.232090 |
AIRLOOP F9 N2 SUPPLY FAN | 0.231339 |
AIRLOOP F9 S1 SUPPLY FAN | 0.251511 |
AIRLOOP F9 S2 SUPPLY FAN | 0.252057 |
AIRLOOP T SW SUPPLY FAN | 0.498347 |
AIRLOOP T NW SUPPLY FAN | 0.483516 |
AIRLOOP T SE SUPPLY FAN | 0.446748 |
AIRLOOP T NE SUPPLY FAN | 0.411296 |
AIRLOOP T N1 SUPPLY FAN | 0.303663 |
AIRLOOP T N2 SUPPLY FAN | 0.303533 |
AIRLOOP T S1 SUPPLY FAN | 0.340092 |
AIRLOOP T S2 SUPPLY FAN | 0.340618 |
Rated Air Flow Rate [m3/s] | Rated Heating Capacity [W] | Rated Water Flow Rate [m3/s] | |
HEAT PUMP HEATING MODE AIRLOOP G SW | 0.330114 | 4944.70 | 0.000108 |
HEAT PUMP HEATING MODE AIRLOOP G NW | 0.322766 | 4819.86 | 0.000105 |
HEAT PUMP HEATING MODE AIRLOOP OFFICE | 0.433493 | 6484.99 | 0.000142 |
HEAT PUMP HEATING MODE AIRLOOP G NE | 0.270374 | 4053.52 | 0.000089 |
HEAT PUMP HEATING MODE AIRLOOP G N1 | 0.178087 | 2825.99 | 0.000062 |
HEAT PUMP HEATING MODE AIRLOOP G N2 | 0.177018 | 2811.26 | 0.000061 |
HEAT PUMP HEATING MODE AIRLOOP G S1 | 0.196515 | 3153.41 | 0.000069 |
HEAT PUMP HEATING MODE AIRLOOP G S2 | 0.202501 | 3235.37 | 0.000071 |
HEAT PUMP HEATING MODE AIRLOOP F2 SW | 0.381788 | 5631.45 | 0.000123 |
HEAT PUMP HEATING MODE AIRLOOP F2 NW | 0.373066 | 5494.17 | 0.000120 |
HEAT PUMP HEATING MODE AIRLOOP F2 SE | 0.360443 | 5311.55 | 0.000116 |
HEAT PUMP HEATING MODE AIRLOOP F2 NE | 0.316151 | 4678.02 | 0.000102 |
HEAT PUMP HEATING MODE AIRLOOP F2 N1 | 0.206184 | 3207.74 | 0.000070 |
HEAT PUMP HEATING MODE AIRLOOP F2 N2 | 0.205352 | 3196.33 | 0.000070 |
HEAT PUMP HEATING MODE AIRLOOP F2 S1 | 0.229405 | 3596.21 | 0.000079 |
HEAT PUMP HEATING MODE AIRLOOP F2 S2 | 0.231322 | 3622.42 | 0.000079 |
HEAT PUMP HEATING MODE AIRLOOP F3 SW | 0.384153 | 5656.23 | 0.000124 |
HEAT PUMP HEATING MODE AIRLOOP F3 NW | 0.375631 | 5521.67 | 0.000121 |
HEAT PUMP HEATING MODE AIRLOOP F3 SE | 0.343406 | 5071.97 | 0.000111 |
HEAT PUMP HEATING MODE AIRLOOP F3 NE | 0.320165 | 4725.41 | 0.000103 |
HEAT PUMP HEATING MODE AIRLOOP F3 N1 | 0.208948 | 3241.26 | 0.000071 |
HEAT PUMP HEATING MODE AIRLOOP F3 N2 | 0.208134 | 3230.10 | 0.000071 |
HEAT PUMP HEATING MODE AIRLOOP F3 S1 | 0.232068 | 3628.31 | 0.000079 |
HEAT PUMP HEATING MODE AIRLOOP F3 S2 | 0.232831 | 3638.75 | 0.000079 |
HEAT PUMP HEATING MODE AIRLOOP F4 SW | 0.387824 | 5700.68 | 0.000125 |
HEAT PUMP HEATING MODE AIRLOOP F4 NW | 0.379237 | 5565.27 | 0.000122 |
HEAT PUMP HEATING MODE AIRLOOP F4 SE | 0.345058 | 5089.00 | 0.000111 |
HEAT PUMP HEATING MODE AIRLOOP F4 NE | 0.323803 | 4769.53 | 0.000104 |
HEAT PUMP HEATING MODE AIRLOOP F4 N1 | 0.212169 | 3282.13 | 0.000072 |
HEAT PUMP HEATING MODE AIRLOOP F4 N2 | 0.211366 | 3271.14 | 0.000071 |
HEAT PUMP HEATING MODE AIRLOOP F4 S1 | 0.234932 | 3664.24 | 0.000080 |
HEAT PUMP HEATING MODE AIRLOOP F4 S2 | 0.235528 | 3672.38 | 0.000080 |
HEAT PUMP HEATING MODE AIRLOOP M SW | 0.393259 | 5775.51 | 0.000126 |
HEAT PUMP HEATING MODE AIRLOOP M NW | 0.384648 | 5636.05 | 0.000123 |
HEAT PUMP HEATING MODE AIRLOOP M SE | 0.350217 | 5154.81 | 0.000113 |
HEAT PUMP HEATING MODE AIRLOOP M NE | 0.329208 | 4838.72 | 0.000106 |
HEAT PUMP HEATING MODE AIRLOOP M N1 | 0.217126 | 3347.39 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP M N2 | 0.216333 | 3336.53 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP M S1 | 0.239569 | 3724.95 | 0.000081 |
HEAT PUMP HEATING MODE AIRLOOP M S2 | 0.240139 | 3732.74 | 0.000082 |
HEAT PUMP HEATING MODE AIRLOOP F6 SW | 0.392695 | 5763.95 | 0.000126 |
HEAT PUMP HEATING MODE AIRLOOP F6 NW | 0.383964 | 5622.84 | 0.000123 |
HEAT PUMP HEATING MODE AIRLOOP F6 SE | 0.349617 | 5142.86 | 0.000112 |
HEAT PUMP HEATING MODE AIRLOOP F6 NE | 0.328548 | 4825.97 | 0.000105 |
HEAT PUMP HEATING MODE AIRLOOP F6 N1 | 0.216199 | 3332.42 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F6 N2 | 0.215418 | 3321.73 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F6 S1 | 0.238500 | 3712.36 | 0.000081 |
HEAT PUMP HEATING MODE AIRLOOP F6 S2 | 0.239043 | 3715.54 | 0.000081 |
HEAT PUMP HEATING MODE AIRLOOP F7 SW | 0.393981 | 5778.07 | 0.000126 |
HEAT PUMP HEATING MODE AIRLOOP F7 NW | 0.385222 | 5636.58 | 0.000123 |
HEAT PUMP HEATING MODE AIRLOOP F7 SE | 0.350885 | 5156.79 | 0.000113 |
HEAT PUMP HEATING MODE AIRLOOP F7 NE | 0.329912 | 4854.16 | 0.000106 |
HEAT PUMP HEATING MODE AIRLOOP F7 N1 | 0.217185 | 3352.76 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F7 N2 | 0.216433 | 3342.47 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F7 S1 | 0.239306 | 3721.41 | 0.000081 |
HEAT PUMP HEATING MODE AIRLOOP F7 S2 | 0.239816 | 3724.14 | 0.000081 |
HEAT PUMP HEATING MODE AIRLOOP F8 SW | 0.396673 | 5811.70 | 0.000127 |
HEAT PUMP HEATING MODE AIRLOOP F8 NW | 0.387908 | 5670.12 | 0.000124 |
HEAT PUMP HEATING MODE AIRLOOP F8 SE | 0.353517 | 5189.65 | 0.000113 |
HEAT PUMP HEATING MODE AIRLOOP F8 NE | 0.332616 | 4888.03 | 0.000107 |
HEAT PUMP HEATING MODE AIRLOOP F8 N1 | 0.219624 | 3384.35 | 0.000074 |
HEAT PUMP HEATING MODE AIRLOOP F8 N2 | 0.218879 | 3374.18 | 0.000074 |
HEAT PUMP HEATING MODE AIRLOOP F8 S1 | 0.241510 | 3749.74 | 0.000082 |
HEAT PUMP HEATING MODE AIRLOOP F8 S2 | 0.242000 | 3756.44 | 0.000082 |
HEAT PUMP HEATING MODE AIRLOOP F9 SW | 0.410112 | 5986.62 | 0.000131 |
HEAT PUMP HEATING MODE AIRLOOP F9 NW | 0.401639 | 5854.40 | 0.000128 |
HEAT PUMP HEATING MODE AIRLOOP F9 SE | 0.362735 | 5321.03 | 0.000116 |
HEAT PUMP HEATING MODE AIRLOOP F9 NE | 0.341442 | 5005.45 | 0.000109 |
HEAT PUMP HEATING MODE AIRLOOP F9 N1 | 0.232090 | 3544.48 | 0.000077 |
HEAT PUMP HEATING MODE AIRLOOP F9 N2 | 0.231339 | 3542.93 | 0.000077 |
HEAT PUMP HEATING MODE AIRLOOP F9 S1 | 0.251511 | 3884.62 | 0.000085 |
HEAT PUMP HEATING MODE AIRLOOP F9 S2 | 0.252057 | 3892.07 | 0.000085 |
HEAT PUMP HEATING MODE AIRLOOP T SW | 0.498347 | 7202.93 | 0.000157 |
HEAT PUMP HEATING MODE AIRLOOP T NW | 0.483516 | 6988.79 | 0.000153 |
HEAT PUMP HEATING MODE AIRLOOP T SE | 0.446748 | 6515.69 | 0.000142 |
HEAT PUMP HEATING MODE AIRLOOP T NE | 0.411296 | 5962.26 | 0.000130 |
HEAT PUMP HEATING MODE AIRLOOP T N1 | 0.303663 | 4594.55 | 0.000100 |
HEAT PUMP HEATING MODE AIRLOOP T N2 | 0.303533 | 4592.76 | 0.000100 |
HEAT PUMP HEATING MODE AIRLOOP T S1 | 0.340092 | 5091.20 | 0.000111 |
HEAT PUMP HEATING MODE AIRLOOP T S2 | 0.340618 | 5098.39 | 0.000111 |
Nominal Capacity [W] | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW | 1814.94 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW | 1816.25 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE | 2375.90 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE | 1811.69 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 | 1282.95 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 | 1282.88 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 | 1279.12 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 | 1285.25 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW | 1769.67 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW | 1770.54 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE | 1784.02 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE | 1765.38 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 | 1140.24 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 | 1140.15 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 | 1142.10 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 | 1143.42 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW | 1753.45 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW | 1754.10 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE | 1750.98 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE | 1749.20 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 | 1105.96 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 | 1105.87 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 | 1105.89 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 | 1106.06 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW | 1768.71 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW | 1769.66 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE | 1764.45 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE | 1765.11 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 | 1107.04 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 | 1106.96 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 | 1106.41 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 | 1106.36 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW | 1768.36 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW | 1768.46 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE | 1764.22 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE | 1764.28 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 | 1097.31 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 | 1097.23 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 | 1097.45 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 | 1097.38 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW | 1825.51 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW | 1826.44 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE | 1821.69 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE | 1822.62 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 | 1141.72 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 | 1141.65 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 | 1141.01 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 | 1140.95 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW | 1861.44 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW | 1862.16 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE | 1857.98 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE | 1858.69 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 | 1168.49 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 | 1168.43 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 | 1167.96 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 | 1167.90 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW | 1900.21 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW | 1900.58 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE | 1897.08 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE | 1897.46 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 | 1199.32 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 | 1199.26 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 | 1199.11 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 | 1199.05 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW | 2022.47 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW | 2021.10 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE | 2019.65 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE | 2018.28 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 | 1307.00 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 | 1306.95 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 | 1308.28 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 | 1308.23 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW | 2441.16 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW | 2443.61 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE | 2438.78 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE | 2441.23 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 | 1757.79 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 | 1757.74 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 | 1754.39 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 | 1754.35 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
SHWSYS1 | 0.000289 | 0.325214 |
SINGLE WATER PLANT LOOP | 0.007913 | 8.90 |
Design Water Flow Rate [m3/s] | |
CENTRAL BOILER | 0.007913 |
Use Side Design Flow Rate [m3/s] | |
SHWSYS1 WATER HEATER | 0.000289 |
Design Water Flow Rate [m3/s] | Fan Power at Design Air Flow Rate [W] | Design Air Flow Rate [m3/s] | U-Factor Times Area Value at Design Air Flow Rate [W/C] | |
CENTRAL TOWER | 0.007913 | 3820.03 | 10.46 | 11385.07 |
Rated Flow Rate [m3/s] | Rated Power Consumption [W] | |
SHWSYS1 PUMP | 0.000289 | 36.93 |
PLANT CIRC PUMP | 0.007913 | 2527.04 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:36
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW3 | |
G WWALL SWA | GWINDOW2 | |
G NWALL NWA | GWINDOW4 | |
G WWALL NWA | GWINDOW6 | |
G SWALL SEA | GWINDOW1 | |
G EWALL SEA | GWINDOW8 | |
G NWALL NEA | GWINDOW5 | |
G EWALL NEA | GWINDOW7 | |
G NWALL N1A | GWINDOW9 | |
G NWALL N2A | GWINDOW10 | |
G SWALL S1A | GWINDOW11 | |
G SWALL S2A | GWINDOW12 | |
G WWALL C | GWINDOW13 | |
G EWALL C | ENTRANCE DOOR | |
F2 WWALL SWA | F2WINDOW2 | |
F2 SWALL SWA | F2WINDOW3 | |
F2 NWALL NWA | F2WINDOW4 | |
F2 WWALL NWA | F2WINDOW6 | |
F2 EWALL SEA | F2WINDOW8 | |
F2 SWALL SEA | F2WINDOW1 | |
F2 NWALL NEA | F2WINDOW5 | |
F2 EWALL NEA | F2WINDOW7 | |
F2 NWALL N1A | F2WINDOW9 | |
F2 NWALL N2A | F2WINDOW10 | |
F2 SWALL S1A | F2WINDOW11 | |
F2 SWALL S2A | F2WINDOW12 | |
F2 WWALL C | F2WINDOW13 | |
F2 EWALL C | F2WINDOW14 | |
F3 WWALL SWA | F3WINDOW2 | |
F3 SWALL SWA | F3WINDOW3 | |
F3 NWALL NWA | F3WINDOW4 | |
F3 WWALL NWA | F3WINDOW6 | |
F3 EWALL SEA | F3WINDOW8 | |
F3 SWALL SEA | F3WINDOW1 | |
F3 NWALL NEA | F3WINDOW5 | |
F3 EWALL NEA | F3WINDOW7 | |
F3 NWALL N1A | F3WINDOW9 | |
F3 NWALL N2A | F3WINDOW10 | |
F3 SWALL S1A | F3WINDOW11 | |
F3 SWALL S2A | F3WINDOW12 | |
F3 WWALL C | F3WINDOW13 | |
F3 EWALL C | F3WINDOW14 | |
F4 WWALL SWA | F4WINDOW2 | |
F4 SWALL SWA | F4WINDOW3 | |
F4 NWALL NWA | F4WINDOW4 | |
F4 WWALL NWA | F4WINDOW6 | |
F4 EWALL SEA | F4WINDOW8 | |
F4 SWALL SEA | F4WINDOW1 | |
F4 NWALL NEA | F4WINDOW5 | |
F4 EWALL NEA | F4WINDOW7 | |
F4 NWALL N1A | F4WINDOW9 | |
F4 NWALL N2A | F4WINDOW10 | |
F4 SWALL S1A | F4WINDOW11 | |
F4 SWALL S2A | F4WINDOW12 | |
F4 WWALL C | F4WINDOW13 | |
F4 EWALL C | F4WINDOW14 | |
M WWALL SWA | MWINDOW2 | |
M SWALL SWA | MWINDOW3 | |
M NWALL NWA | MWINDOW4 | |
M WWALL NWA | MWINDOW6 | |
M EWALL SEA | MWINDOW8 | |
M SWALL SEA | MWINDOW1 | |
M NWALL NEA | MWINDOW5 | |
M EWALL NEA | MWINDOW7 | |
M NWALL N1A | MWINDOW9 | |
M NWALL N2A | MWINDOW10 | |
M SWALL S1A | MWINDOW11 | |
M SWALL S2A | MWINDOW12 | |
M WWALL C | MWINDOW13 | |
M EWALL C | MWINDOW14 | |
F6 WWALL SWA | F6WINDOW2 | |
F6 SWALL SWA | F6WINDOW3 | |
F6 NWALL NWA | F6WINDOW4 | |
F6 WWALL NWA | F6WINDOW6 | |
F6 EWALL SEA | F6WINDOW8 | |
F6 SWALL SEA | F6WINDOW1 | |
F6 NWALL NEA | F6WINDOW5 | |
F6 EWALL NEA | F6WINDOW7 | |
F6 NWALL N1A | F6WINDOW9 | |
F6 NWALL N2A | F6WINDOW10 | |
F6 SWALL S1A | F6WINDOW11 | |
F6 SWALL S2A | F6WINDOW12 | |
F6 WWALL C | F6WINDOW13 | |
F6 EWALL C | F6WINDOW14 | |
F7 WWALL SWA | F7WINDOW2 | |
F7 SWALL SWA | F7WINDOW3 | |
F7 NWALL NWA | F7WINDOW4 | |
F7 WWALL NWA | F7WINDOW6 | |
F7 EWALL SEA | F7WINDOW8 | |
F7 SWALL SEA | F7WINDOW1 | |
F7 NWALL NEA | F7WINDOW5 | |
F7 EWALL NEA | F7WINDOW7 | |
F7 NWALL N1A | F7WINDOW9 | |
F7 NWALL N2A | F7WINDOW10 | |
F7 SWALL S1A | F7WINDOW11 | |
F7 SWALL S2A | F7WINDOW12 | |
F7 WWALL C | F7WINDOW13 | |
F7 EWALL C | F7WINDOW14 | |
F8 WWALL SWA | F8WINDOW2 | |
F8 SWALL SWA | F8WINDOW3 | |
F8 NWALL NWA | F8WINDOW4 | |
F8 WWALL NWA | F8WINDOW6 | |
F8 EWALL SEA | F8WINDOW8 | |
F8 SWALL SEA | F8WINDOW1 | |
F8 NWALL NEA | F8WINDOW5 | |
F8 EWALL NEA | F8WINDOW7 | |
F8 NWALL N1A | F8WINDOW9 | |
F8 NWALL N2A | F8WINDOW10 | |
F8 SWALL S1A | F8WINDOW11 | |
F8 SWALL S2A | F8WINDOW12 | |
F8 WWALL C | F8WINDOW13 | |
F8 EWALL C | F8WINDOW14 | |
F9 WWALL SWA | F9WINDOW2 | |
F9 SWALL SWA | F9WINDOW3 | |
F9 NWALL NWA | F9WINDOW4 | |
F9 WWALL NWA | F9WINDOW6 | |
F9 EWALL SEA | F9WINDOW8 | |
F9 SWALL SEA | F9WINDOW1 | |
F9 NWALL NEA | F9WINDOW5 | |
F9 EWALL NEA | F9WINDOW7 | |
F9 NWALL N1A | F9WINDOW9 | |
F9 NWALL N2A | F9WINDOW10 | |
F9 SWALL S1A | F9WINDOW11 | |
F9 SWALL S2A | F9WINDOW12 | |
F9 WWALL C | F9WINDOW13 | |
F9 EWALL C | F9WINDOW14 | |
T WWALL SWA | TWINDOW2 | |
T SWALL SWA | TWINDOW3 | |
T NWALL NWA | TWINDOW4 | |
T WWALL NWA | TWINDOW6 | |
T EWALL SEA | TWINDOW8 | |
T SWALL SEA | TWINDOW1 | |
T NWALL NEA | TWINDOW5 | |
T EWALL NEA | TWINDOW7 | |
T NWALL N1A | TWINDOW9 | |
T NWALL N2A | TWINDOW10 | |
T SWALL S1A | TWINDOW11 | |
T SWALL S2A | TWINDOW12 | |
T WWALL C | TWINDOW13 | |
T EWALL C | TWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:36
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.14 | 13.01 |
February | 23.43 | 15.66 |
March | 23.70 | 17.34 |
April | 24.07 | 23.65 |
May | 24.31 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.42 | 33.82 |
September | 24.42 | 30.39 |
October | 24.32 | 24.81 |
November | 23.98 | 17.95 |
December | 23.12 | 11.71 |
Annual Sum or Average | 23.98 | 23.80 |
Minimum of Months | 23.12 | 11.71 |
Maximum of Months | 24.42 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.32 | 13.01 |
February | 22.90 | 15.66 |
March | 23.41 | 17.34 |
April | 24.01 | 23.65 |
May | 24.31 | 27.29 |
June | 24.41 | 33.99 |
July | 24.42 | 35.56 |
August | 24.41 | 33.82 |
September | 24.40 | 30.39 |
October | 24.25 | 24.81 |
November | 23.53 | 17.95 |
December | 22.21 | 11.71 |
Annual Sum or Average | 23.72 | 23.80 |
Minimum of Months | 22.21 | 11.71 |
Maximum of Months | 24.42 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.40 | 13.01 |
February | 23.72 | 15.66 |
March | 23.96 | 17.34 |
April | 24.24 | 23.65 |
May | 24.39 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.36 | 24.81 |
November | 24.15 | 17.95 |
December | 23.30 | 11.71 |
Annual Sum or Average | 24.09 | 23.80 |
Minimum of Months | 23.30 | 11.71 |
Maximum of Months | 24.40 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.22 | 13.01 |
February | 22.87 | 15.66 |
March | 23.41 | 17.34 |
April | 24.04 | 23.65 |
May | 24.32 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.27 | 24.81 |
November | 23.56 | 17.95 |
December | 22.11 | 11.71 |
Annual Sum or Average | 23.70 | 23.80 |
Minimum of Months | 22.11 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.10 | 13.01 |
February | 22.70 | 15.66 |
March | 23.19 | 17.34 |
April | 23.93 | 23.65 |
May | 24.28 | 27.29 |
June | 24.40 | 33.99 |
July | 24.42 | 35.56 |
August | 24.41 | 33.82 |
September | 24.40 | 30.39 |
October | 24.21 | 24.81 |
November | 23.37 | 17.95 |
December | 22.01 | 11.71 |
Annual Sum or Average | 23.62 | 23.80 |
Minimum of Months | 22.01 | 11.71 |
Maximum of Months | 24.42 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.10 | 13.01 |
February | 22.69 | 15.66 |
March | 23.19 | 17.34 |
April | 23.93 | 23.65 |
May | 24.28 | 27.29 |
June | 24.40 | 33.99 |
July | 24.42 | 35.56 |
August | 24.41 | 33.82 |
September | 24.40 | 30.39 |
October | 24.21 | 24.81 |
November | 23.37 | 17.95 |
December | 22.00 | 11.71 |
Annual Sum or Average | 23.62 | 23.80 |
Minimum of Months | 22.00 | 11.71 |
Maximum of Months | 24.42 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.20 | 13.01 |
February | 23.44 | 15.66 |
March | 23.66 | 17.34 |
April | 24.05 | 23.65 |
May | 24.29 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.43 | 33.82 |
September | 24.45 | 30.39 |
October | 24.33 | 24.81 |
November | 24.01 | 17.95 |
December | 23.19 | 11.71 |
Annual Sum or Average | 23.99 | 23.80 |
Minimum of Months | 23.19 | 11.71 |
Maximum of Months | 24.45 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.24 | 13.01 |
February | 23.48 | 15.66 |
March | 23.69 | 17.34 |
April | 24.06 | 23.65 |
May | 24.29 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.42 | 33.82 |
September | 24.45 | 30.39 |
October | 24.33 | 24.81 |
November | 24.03 | 17.95 |
December | 23.23 | 11.71 |
Annual Sum or Average | 24.00 | 23.80 |
Minimum of Months | 23.23 | 11.71 |
Maximum of Months | 24.45 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.44 | 13.01 |
February | 21.52 | 15.66 |
March | 22.33 | 17.34 |
April | 24.77 | 23.65 |
May | 26.10 | 27.29 |
June | 28.78 | 33.99 |
July | 29.31 | 35.56 |
August | 28.78 | 33.82 |
September | 27.77 | 30.39 |
October | 25.36 | 24.81 |
November | 22.71 | 17.95 |
December | 20.00 | 11.71 |
Annual Sum or Average | 24.84 | 23.80 |
Minimum of Months | 20.00 | 11.71 |
Maximum of Months | 29.31 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F2 SW APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.82 | 13.01 |
February | 23.92 | 15.66 |
March | 24.08 | 17.34 |
April | 24.25 | 23.65 |
May | 24.37 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.41 | 33.82 |
September | 24.41 | 30.39 |
October | 24.39 | 24.81 |
November | 24.33 | 17.95 |
December | 23.74 | 11.71 |
Annual Sum or Average | 24.21 | 23.80 |
Minimum of Months | 23.74 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F2 NW APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.82 | 13.01 |
February | 23.37 | 15.66 |
March | 23.86 | 17.34 |
April | 24.18 | 23.65 |
May | 24.37 | 27.29 |
June | 24.41 | 33.99 |
July | 24.41 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.35 | 24.81 |
November | 24.05 | 17.95 |
December | 22.63 | 11.71 |
Annual Sum or Average | 23.94 | 23.80 |
Minimum of Months | 22.63 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F2 SE APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.86 | 13.01 |
February | 23.98 | 15.66 |
March | 24.11 | 17.34 |
April | 24.29 | 23.65 |
May | 24.38 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.39 | 24.81 |
November | 24.34 | 17.95 |
December | 23.78 | 11.71 |
Annual Sum or Average | 24.23 | 23.80 |
Minimum of Months | 23.78 | 11.71 |
Maximum of Months | 24.40 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F2 NE APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.67 | 13.01 |
February | 23.31 | 15.66 |
March | 23.85 | 17.34 |
April | 24.21 | 23.65 |
May | 24.37 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.36 | 24.81 |
November | 24.06 | 17.95 |
December | 22.49 | 11.71 |
Annual Sum or Average | 23.91 | 23.80 |
Minimum of Months | 22.49 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F2 N1 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.62 | 13.01 |
February | 23.21 | 15.66 |
March | 23.74 | 17.34 |
April | 24.15 | 23.65 |
May | 24.36 | 27.29 |
June | 24.41 | 33.99 |
July | 24.42 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.35 | 24.81 |
November | 23.98 | 17.95 |
December | 22.44 | 11.71 |
Annual Sum or Average | 23.87 | 23.80 |
Minimum of Months | 22.44 | 11.71 |
Maximum of Months | 24.42 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F2 N2 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.61 | 13.01 |
February | 23.21 | 15.66 |
March | 23.74 | 17.34 |
April | 24.15 | 23.65 |
May | 24.36 | 27.29 |
June | 24.41 | 33.99 |
July | 24.42 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.35 | 24.81 |
November | 23.98 | 17.95 |
December | 22.43 | 11.71 |
Annual Sum or Average | 23.87 | 23.80 |
Minimum of Months | 22.43 | 11.71 |
Maximum of Months | 24.42 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F2 S1 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.96 | 13.01 |
February | 24.00 | 15.66 |
March | 24.08 | 17.34 |
April | 24.25 | 23.65 |
May | 24.36 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.42 | 33.82 |
September | 24.45 | 30.39 |
October | 24.43 | 24.81 |
November | 24.35 | 17.95 |
December | 23.91 | 11.71 |
Annual Sum or Average | 24.25 | 23.80 |
Minimum of Months | 23.91 | 11.71 |
Maximum of Months | 24.45 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F2 S2 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.97 | 13.01 |
February | 24.01 | 15.66 |
March | 24.09 | 17.34 |
April | 24.26 | 23.65 |
May | 24.36 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.42 | 33.82 |
September | 24.45 | 30.39 |
October | 24.43 | 24.81 |
November | 24.35 | 17.95 |
December | 23.92 | 11.71 |
Annual Sum or Average | 24.25 | 23.80 |
Minimum of Months | 23.92 | 11.71 |
Maximum of Months | 24.45 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F2 CORRIDOR
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.05 | 13.01 |
February | 24.56 | 15.66 |
March | 25.13 | 17.34 |
April | 25.93 | 23.65 |
May | 26.45 | 27.29 |
June | 27.21 | 33.99 |
July | 27.35 | 35.56 |
August | 27.20 | 33.82 |
September | 26.93 | 30.39 |
October | 26.26 | 24.81 |
November | 25.39 | 17.95 |
December | 23.85 | 11.71 |
Annual Sum or Average | 25.87 | 23.80 |
Minimum of Months | 23.85 | 11.71 |
Maximum of Months | 27.35 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F3 SW APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.93 | 13.01 |
February | 23.99 | 15.66 |
March | 24.11 | 17.34 |
April | 24.26 | 23.65 |
May | 24.37 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.41 | 33.82 |
September | 24.41 | 30.39 |
October | 24.40 | 24.81 |
November | 24.35 | 17.95 |
December | 23.84 | 11.71 |
Annual Sum or Average | 24.24 | 23.80 |
Minimum of Months | 23.84 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F3 NW APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.97 | 13.01 |
February | 23.47 | 15.66 |
March | 23.93 | 17.34 |
April | 24.20 | 23.65 |
May | 24.37 | 27.29 |
June | 24.41 | 33.99 |
July | 24.41 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.37 | 24.81 |
November | 24.14 | 17.95 |
December | 22.76 | 11.71 |
Annual Sum or Average | 23.99 | 23.80 |
Minimum of Months | 22.76 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F3 SE APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.88 | 13.01 |
February | 23.98 | 15.66 |
March | 24.11 | 17.34 |
April | 24.29 | 23.65 |
May | 24.38 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.41 | 33.82 |
September | 24.41 | 30.39 |
October | 24.39 | 24.81 |
November | 24.35 | 17.95 |
December | 23.79 | 11.71 |
Annual Sum or Average | 24.23 | 23.80 |
Minimum of Months | 23.79 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F3 NE APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.82 | 13.01 |
February | 23.40 | 15.66 |
March | 23.91 | 17.34 |
April | 24.23 | 23.65 |
May | 24.38 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.37 | 24.81 |
November | 24.14 | 17.95 |
December | 22.61 | 11.71 |
Annual Sum or Average | 23.96 | 23.80 |
Minimum of Months | 22.61 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F3 N1 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.84 | 13.01 |
February | 23.37 | 15.66 |
March | 23.85 | 17.34 |
April | 24.18 | 23.65 |
May | 24.36 | 27.29 |
June | 24.41 | 33.99 |
July | 24.42 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.36 | 24.81 |
November | 24.10 | 17.95 |
December | 22.64 | 11.71 |
Annual Sum or Average | 23.95 | 23.80 |
Minimum of Months | 22.64 | 11.71 |
Maximum of Months | 24.42 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F3 N2 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.82 | 13.01 |
February | 23.36 | 15.66 |
March | 23.85 | 17.34 |
April | 24.19 | 23.65 |
May | 24.36 | 27.29 |
June | 24.41 | 33.99 |
July | 24.43 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.36 | 24.81 |
November | 24.10 | 17.95 |
December | 22.62 | 11.71 |
Annual Sum or Average | 23.94 | 23.80 |
Minimum of Months | 22.62 | 11.71 |
Maximum of Months | 24.43 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F3 S1 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.09 | 13.01 |
February | 24.10 | 15.66 |
March | 24.14 | 17.34 |
April | 24.28 | 23.65 |
May | 24.36 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.42 | 33.82 |
September | 24.44 | 30.39 |
October | 24.44 | 24.81 |
November | 24.37 | 17.95 |
December | 24.05 | 11.71 |
Annual Sum or Average | 24.29 | 23.80 |
Minimum of Months | 24.05 | 11.71 |
Maximum of Months | 24.44 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F3 S2 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.09 | 13.01 |
February | 24.10 | 15.66 |
March | 24.14 | 17.34 |
April | 24.28 | 23.65 |
May | 24.36 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.42 | 33.82 |
September | 24.44 | 30.39 |
October | 24.44 | 24.81 |
November | 24.37 | 17.95 |
December | 24.05 | 11.71 |
Annual Sum or Average | 24.29 | 23.80 |
Minimum of Months | 24.05 | 11.71 |
Maximum of Months | 24.44 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F3 CORRIDOR
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.53 | 13.01 |
February | 24.99 | 15.66 |
March | 25.51 | 17.34 |
April | 26.16 | 23.65 |
May | 26.60 | 27.29 |
June | 27.15 | 33.99 |
July | 27.26 | 35.56 |
August | 27.12 | 33.82 |
September | 26.91 | 30.39 |
October | 26.44 | 24.81 |
November | 25.77 | 17.95 |
December | 24.33 | 11.71 |
Annual Sum or Average | 26.07 | 23.80 |
Minimum of Months | 24.33 | 11.71 |
Maximum of Months | 27.26 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F4 SW APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.95 | 13.01 |
February | 24.00 | 15.66 |
March | 24.13 | 17.34 |
April | 24.26 | 23.65 |
May | 24.37 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.41 | 33.82 |
September | 24.41 | 30.39 |
October | 24.39 | 24.81 |
November | 24.36 | 17.95 |
December | 23.85 | 11.71 |
Annual Sum or Average | 24.25 | 23.80 |
Minimum of Months | 23.85 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F4 NW APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.04 | 13.01 |
February | 23.52 | 15.66 |
March | 23.95 | 17.34 |
April | 24.20 | 23.65 |
May | 24.37 | 27.29 |
June | 24.41 | 33.99 |
July | 24.42 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.37 | 24.81 |
November | 24.16 | 17.95 |
December | 22.82 | 11.71 |
Annual Sum or Average | 24.01 | 23.80 |
Minimum of Months | 22.82 | 11.71 |
Maximum of Months | 24.42 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F4 SE APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.89 | 13.01 |
February | 23.97 | 15.66 |
March | 24.11 | 17.34 |
April | 24.28 | 23.65 |
May | 24.38 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.41 | 33.82 |
September | 24.41 | 30.39 |
October | 24.39 | 24.81 |
November | 24.35 | 17.95 |
December | 23.79 | 11.71 |
Annual Sum or Average | 24.23 | 23.80 |
Minimum of Months | 23.79 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F4 NE APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.88 | 13.01 |
February | 23.45 | 15.66 |
March | 23.93 | 17.34 |
April | 24.23 | 23.65 |
May | 24.38 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.37 | 24.81 |
November | 24.17 | 17.95 |
December | 22.67 | 11.71 |
Annual Sum or Average | 23.98 | 23.80 |
Minimum of Months | 22.67 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F4 N1 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.94 | 13.01 |
February | 23.44 | 15.66 |
March | 23.89 | 17.34 |
April | 24.20 | 23.65 |
May | 24.36 | 27.29 |
June | 24.41 | 33.99 |
July | 24.43 | 35.56 |
August | 24.41 | 33.82 |
September | 24.40 | 30.39 |
October | 24.36 | 24.81 |
November | 24.15 | 17.95 |
December | 22.74 | 11.71 |
Annual Sum or Average | 23.98 | 23.80 |
Minimum of Months | 22.74 | 11.71 |
Maximum of Months | 24.43 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F4 N2 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.93 | 13.01 |
February | 23.43 | 15.66 |
March | 23.89 | 17.34 |
April | 24.20 | 23.65 |
May | 24.36 | 27.29 |
June | 24.41 | 33.99 |
July | 24.43 | 35.56 |
August | 24.41 | 33.82 |
September | 24.40 | 30.39 |
October | 24.36 | 24.81 |
November | 24.15 | 17.95 |
December | 22.72 | 11.71 |
Annual Sum or Average | 23.97 | 23.80 |
Minimum of Months | 22.72 | 11.71 |
Maximum of Months | 24.43 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F4 S1 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.12 | 13.01 |
February | 24.12 | 15.66 |
March | 24.16 | 17.34 |
April | 24.28 | 23.65 |
May | 24.36 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.42 | 33.82 |
September | 24.44 | 30.39 |
October | 24.44 | 24.81 |
November | 24.38 | 17.95 |
December | 24.08 | 11.71 |
Annual Sum or Average | 24.30 | 23.80 |
Minimum of Months | 24.08 | 11.71 |
Maximum of Months | 24.44 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F4 S2 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.12 | 13.01 |
February | 24.12 | 15.66 |
March | 24.16 | 17.34 |
April | 24.28 | 23.65 |
May | 24.36 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.42 | 33.82 |
September | 24.44 | 30.39 |
October | 24.44 | 24.81 |
November | 24.38 | 17.95 |
December | 24.07 | 11.71 |
Annual Sum or Average | 24.30 | 23.80 |
Minimum of Months | 24.07 | 11.71 |
Maximum of Months | 24.44 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F4 CORRIDOR
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.71 | 13.01 |
February | 25.15 | 15.66 |
March | 25.66 | 17.34 |
April | 26.27 | 23.65 |
May | 26.70 | 27.29 |
June | 27.21 | 33.99 |
July | 27.32 | 35.56 |
August | 27.18 | 33.82 |
September | 26.97 | 30.39 |
October | 26.53 | 24.81 |
November | 25.91 | 17.95 |
December | 24.51 | 11.71 |
Annual Sum or Average | 26.18 | 23.80 |
Minimum of Months | 24.51 | 11.71 |
Maximum of Months | 27.32 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.95 | 13.01 |
February | 23.99 | 15.66 |
March | 24.12 | 17.34 |
April | 24.26 | 23.65 |
May | 24.37 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.41 | 33.82 |
September | 24.41 | 30.39 |
October | 24.39 | 24.81 |
November | 24.36 | 17.95 |
December | 23.85 | 11.71 |
Annual Sum or Average | 24.24 | 23.80 |
Minimum of Months | 23.85 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.05 | 13.01 |
February | 23.53 | 15.66 |
March | 23.96 | 17.34 |
April | 24.19 | 23.65 |
May | 24.37 | 27.29 |
June | 24.41 | 33.99 |
July | 24.42 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.37 | 24.81 |
November | 24.17 | 17.95 |
December | 22.84 | 11.71 |
Annual Sum or Average | 24.01 | 23.80 |
Minimum of Months | 22.84 | 11.71 |
Maximum of Months | 24.42 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.88 | 13.01 |
February | 23.97 | 15.66 |
March | 24.11 | 17.34 |
April | 24.28 | 23.65 |
May | 24.38 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.40 | 33.82 |
September | 24.41 | 30.39 |
October | 24.39 | 24.81 |
November | 24.35 | 17.95 |
December | 23.79 | 11.71 |
Annual Sum or Average | 24.23 | 23.80 |
Minimum of Months | 23.79 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.90 | 13.01 |
February | 23.46 | 15.66 |
March | 23.94 | 17.34 |
April | 24.22 | 23.65 |
May | 24.38 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.37 | 24.81 |
November | 24.18 | 17.95 |
December | 22.69 | 11.71 |
Annual Sum or Average | 23.98 | 23.80 |
Minimum of Months | 22.69 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.99 | 13.01 |
February | 23.47 | 15.66 |
March | 23.91 | 17.34 |
April | 24.19 | 23.65 |
May | 24.36 | 27.29 |
June | 24.41 | 33.99 |
July | 24.43 | 35.56 |
August | 24.41 | 33.82 |
September | 24.40 | 30.39 |
October | 24.37 | 24.81 |
November | 24.16 | 17.95 |
December | 22.78 | 11.71 |
Annual Sum or Average | 23.99 | 23.80 |
Minimum of Months | 22.78 | 11.71 |
Maximum of Months | 24.43 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.97 | 13.01 |
February | 23.46 | 15.66 |
March | 23.90 | 17.34 |
April | 24.20 | 23.65 |
May | 24.36 | 27.29 |
June | 24.41 | 33.99 |
July | 24.43 | 35.56 |
August | 24.41 | 33.82 |
September | 24.40 | 30.39 |
October | 24.37 | 24.81 |
November | 24.16 | 17.95 |
December | 22.77 | 11.71 |
Annual Sum or Average | 23.99 | 23.80 |
Minimum of Months | 22.77 | 11.71 |
Maximum of Months | 24.43 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.13 | 13.01 |
February | 24.13 | 15.66 |
March | 24.16 | 17.34 |
April | 24.28 | 23.65 |
May | 24.36 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.42 | 33.82 |
September | 24.44 | 30.39 |
October | 24.43 | 24.81 |
November | 24.38 | 17.95 |
December | 24.09 | 11.71 |
Annual Sum or Average | 24.30 | 23.80 |
Minimum of Months | 24.09 | 11.71 |
Maximum of Months | 24.44 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.13 | 13.01 |
February | 24.12 | 15.66 |
March | 24.16 | 17.34 |
April | 24.28 | 23.65 |
May | 24.36 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.42 | 33.82 |
September | 24.44 | 30.39 |
October | 24.43 | 24.81 |
November | 24.38 | 17.95 |
December | 24.08 | 11.71 |
Annual Sum or Average | 24.30 | 23.80 |
Minimum of Months | 24.08 | 11.71 |
Maximum of Months | 24.44 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 25.29 | 13.01 |
February | 25.71 | 15.66 |
March | 26.21 | 17.34 |
April | 26.79 | 23.65 |
May | 27.22 | 27.29 |
June | 27.72 | 33.99 |
July | 27.83 | 35.56 |
August | 27.69 | 33.82 |
September | 27.49 | 30.39 |
October | 27.06 | 24.81 |
November | 26.47 | 17.95 |
December | 25.09 | 11.71 |
Annual Sum or Average | 26.72 | 23.80 |
Minimum of Months | 25.09 | 11.71 |
Maximum of Months | 27.83 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F6 SW APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.89 | 13.01 |
February | 23.95 | 15.66 |
March | 24.10 | 17.34 |
April | 24.23 | 23.65 |
May | 24.37 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.41 | 33.82 |
September | 24.41 | 30.39 |
October | 24.39 | 24.81 |
November | 24.35 | 17.95 |
December | 23.79 | 11.71 |
Annual Sum or Average | 24.23 | 23.80 |
Minimum of Months | 23.79 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F6 NW APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.96 | 13.01 |
February | 23.46 | 15.66 |
March | 23.92 | 17.34 |
April | 24.17 | 23.65 |
May | 24.37 | 27.29 |
June | 24.41 | 33.99 |
July | 24.42 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.36 | 24.81 |
November | 24.14 | 17.95 |
December | 22.75 | 11.71 |
Annual Sum or Average | 23.98 | 23.80 |
Minimum of Months | 22.75 | 11.71 |
Maximum of Months | 24.42 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F6 SE APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.82 | 13.01 |
February | 23.92 | 15.66 |
March | 24.08 | 17.34 |
April | 24.26 | 23.65 |
May | 24.37 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.40 | 33.82 |
September | 24.41 | 30.39 |
October | 24.39 | 24.81 |
November | 24.34 | 17.95 |
December | 23.73 | 11.71 |
Annual Sum or Average | 24.21 | 23.80 |
Minimum of Months | 23.73 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F6 NE APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.80 | 13.01 |
February | 23.39 | 15.66 |
March | 23.90 | 17.34 |
April | 24.20 | 23.65 |
May | 24.37 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.37 | 24.81 |
November | 24.15 | 17.95 |
December | 22.60 | 11.71 |
Annual Sum or Average | 23.95 | 23.80 |
Minimum of Months | 22.60 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F6 N1 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.88 | 13.01 |
February | 23.40 | 15.66 |
March | 23.86 | 17.34 |
April | 24.17 | 23.65 |
May | 24.36 | 27.29 |
June | 24.41 | 33.99 |
July | 24.43 | 35.56 |
August | 24.41 | 33.82 |
September | 24.40 | 30.39 |
October | 24.36 | 24.81 |
November | 24.13 | 17.95 |
December | 22.69 | 11.71 |
Annual Sum or Average | 23.96 | 23.80 |
Minimum of Months | 22.69 | 11.71 |
Maximum of Months | 24.43 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F6 N2 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.87 | 13.01 |
February | 23.39 | 15.66 |
March | 23.86 | 17.34 |
April | 24.17 | 23.65 |
May | 24.36 | 27.29 |
June | 24.41 | 33.99 |
July | 24.43 | 35.56 |
August | 24.41 | 33.82 |
September | 24.40 | 30.39 |
October | 24.36 | 24.81 |
November | 24.13 | 17.95 |
December | 22.67 | 11.71 |
Annual Sum or Average | 23.95 | 23.80 |
Minimum of Months | 22.67 | 11.71 |
Maximum of Months | 24.43 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F6 S1 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.08 | 13.01 |
February | 24.08 | 15.66 |
March | 24.13 | 17.34 |
April | 24.26 | 23.65 |
May | 24.36 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.41 | 33.82 |
September | 24.43 | 30.39 |
October | 24.42 | 24.81 |
November | 24.37 | 17.95 |
December | 24.04 | 11.71 |
Annual Sum or Average | 24.28 | 23.80 |
Minimum of Months | 24.04 | 11.71 |
Maximum of Months | 24.43 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F6 S2 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.08 | 13.01 |
February | 24.08 | 15.66 |
March | 24.13 | 17.34 |
April | 24.26 | 23.65 |
May | 24.36 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.41 | 33.82 |
September | 24.43 | 30.39 |
October | 24.43 | 24.81 |
November | 24.37 | 17.95 |
December | 24.04 | 11.71 |
Annual Sum or Average | 24.28 | 23.80 |
Minimum of Months | 24.04 | 11.71 |
Maximum of Months | 24.43 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F6 CORRIDOR
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.66 | 13.01 |
February | 25.10 | 15.66 |
March | 25.62 | 17.34 |
April | 26.23 | 23.65 |
May | 26.68 | 27.29 |
June | 27.21 | 33.99 |
July | 27.32 | 35.56 |
August | 27.17 | 33.82 |
September | 26.96 | 30.39 |
October | 26.52 | 24.81 |
November | 25.89 | 17.95 |
December | 24.46 | 11.71 |
Annual Sum or Average | 26.16 | 23.80 |
Minimum of Months | 24.46 | 11.71 |
Maximum of Months | 27.32 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F7 SW APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.84 | 13.01 |
February | 23.92 | 15.66 |
March | 24.08 | 17.34 |
April | 24.22 | 23.65 |
May | 24.36 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.41 | 33.82 |
September | 24.41 | 30.39 |
October | 24.39 | 24.81 |
November | 24.34 | 17.95 |
December | 23.75 | 11.71 |
Annual Sum or Average | 24.21 | 23.80 |
Minimum of Months | 23.75 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F7 NW APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.89 | 13.01 |
February | 23.42 | 15.66 |
March | 23.89 | 17.34 |
April | 24.15 | 23.65 |
May | 24.36 | 27.29 |
June | 24.41 | 33.99 |
July | 24.42 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.35 | 24.81 |
November | 24.11 | 17.95 |
December | 22.68 | 11.71 |
Annual Sum or Average | 23.96 | 23.80 |
Minimum of Months | 22.68 | 11.71 |
Maximum of Months | 24.42 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F7 SE APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.77 | 13.01 |
February | 23.89 | 15.66 |
March | 24.06 | 17.34 |
April | 24.24 | 23.65 |
May | 24.37 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.40 | 33.82 |
September | 24.41 | 30.39 |
October | 24.39 | 24.81 |
November | 24.33 | 17.95 |
December | 23.68 | 11.71 |
Annual Sum or Average | 24.20 | 23.80 |
Minimum of Months | 23.68 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F7 NE APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.74 | 13.01 |
February | 23.34 | 15.66 |
March | 23.87 | 17.34 |
April | 24.18 | 23.65 |
May | 24.37 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.36 | 24.81 |
November | 24.12 | 17.95 |
December | 22.53 | 11.71 |
Annual Sum or Average | 23.93 | 23.80 |
Minimum of Months | 22.53 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F7 N1 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.81 | 13.01 |
February | 23.35 | 15.66 |
March | 23.83 | 17.34 |
April | 24.15 | 23.65 |
May | 24.35 | 27.29 |
June | 24.41 | 33.99 |
July | 24.43 | 35.56 |
August | 24.41 | 33.82 |
September | 24.40 | 30.39 |
October | 24.35 | 24.81 |
November | 24.10 | 17.95 |
December | 22.61 | 11.71 |
Annual Sum or Average | 23.94 | 23.80 |
Minimum of Months | 22.61 | 11.71 |
Maximum of Months | 24.43 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F7 N2 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.80 | 13.01 |
February | 23.34 | 15.66 |
March | 23.83 | 17.34 |
April | 24.15 | 23.65 |
May | 24.35 | 27.29 |
June | 24.41 | 33.99 |
July | 24.43 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.35 | 24.81 |
November | 24.10 | 17.95 |
December | 22.60 | 11.71 |
Annual Sum or Average | 23.93 | 23.80 |
Minimum of Months | 22.60 | 11.71 |
Maximum of Months | 24.43 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F7 S1 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.05 | 13.01 |
February | 24.05 | 15.66 |
March | 24.12 | 17.34 |
April | 24.24 | 23.65 |
May | 24.35 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.41 | 33.82 |
September | 24.43 | 30.39 |
October | 24.42 | 24.81 |
November | 24.37 | 17.95 |
December | 24.00 | 11.71 |
Annual Sum or Average | 24.27 | 23.80 |
Minimum of Months | 24.00 | 11.71 |
Maximum of Months | 24.43 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F7 S2 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.05 | 13.01 |
February | 24.05 | 15.66 |
March | 24.11 | 17.34 |
April | 24.24 | 23.65 |
May | 24.35 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.41 | 33.82 |
September | 24.43 | 30.39 |
October | 24.42 | 24.81 |
November | 24.37 | 17.95 |
December | 24.00 | 11.71 |
Annual Sum or Average | 24.27 | 23.80 |
Minimum of Months | 24.00 | 11.71 |
Maximum of Months | 24.43 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F7 CORRIDOR
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.51 | 13.01 |
February | 24.97 | 15.66 |
March | 25.51 | 17.34 |
April | 26.13 | 23.65 |
May | 26.61 | 27.29 |
June | 27.15 | 33.99 |
July | 27.27 | 35.56 |
August | 27.11 | 33.82 |
September | 26.90 | 30.39 |
October | 26.44 | 24.81 |
November | 25.79 | 17.95 |
December | 24.31 | 11.71 |
Annual Sum or Average | 26.06 | 23.80 |
Minimum of Months | 24.31 | 11.71 |
Maximum of Months | 27.27 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F8 SW APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.80 | 13.01 |
February | 23.89 | 15.66 |
March | 24.07 | 17.34 |
April | 24.20 | 23.65 |
May | 24.36 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.41 | 33.82 |
September | 24.41 | 30.39 |
October | 24.38 | 24.81 |
November | 24.34 | 17.95 |
December | 23.70 | 11.71 |
Annual Sum or Average | 24.20 | 23.80 |
Minimum of Months | 23.70 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F8 NW APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.83 | 13.01 |
February | 23.38 | 15.66 |
March | 23.87 | 17.34 |
April | 24.13 | 23.65 |
May | 24.36 | 27.29 |
June | 24.41 | 33.99 |
July | 24.42 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.35 | 24.81 |
November | 24.09 | 17.95 |
December | 22.63 | 11.71 |
Annual Sum or Average | 23.94 | 23.80 |
Minimum of Months | 22.63 | 11.71 |
Maximum of Months | 24.42 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F8 SE APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.72 | 13.01 |
February | 23.86 | 15.66 |
March | 24.05 | 17.34 |
April | 24.23 | 23.65 |
May | 24.37 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.40 | 33.82 |
September | 24.41 | 30.39 |
October | 24.38 | 24.81 |
November | 24.32 | 17.95 |
December | 23.64 | 11.71 |
Annual Sum or Average | 24.18 | 23.80 |
Minimum of Months | 23.64 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F8 NE APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.68 | 13.01 |
February | 23.31 | 15.66 |
March | 23.85 | 17.34 |
April | 24.16 | 23.65 |
May | 24.37 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.36 | 24.81 |
November | 24.10 | 17.95 |
December | 22.48 | 11.71 |
Annual Sum or Average | 23.91 | 23.80 |
Minimum of Months | 22.48 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F8 N1 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.75 | 13.01 |
February | 23.31 | 15.66 |
March | 23.81 | 17.34 |
April | 24.13 | 23.65 |
May | 24.35 | 27.29 |
June | 24.41 | 33.99 |
July | 24.43 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.35 | 24.81 |
November | 24.08 | 17.95 |
December | 22.56 | 11.71 |
Annual Sum or Average | 23.92 | 23.80 |
Minimum of Months | 22.56 | 11.71 |
Maximum of Months | 24.43 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F8 N2 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.74 | 13.01 |
February | 23.31 | 15.66 |
March | 23.80 | 17.34 |
April | 24.13 | 23.65 |
May | 24.35 | 27.29 |
June | 24.41 | 33.99 |
July | 24.43 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.35 | 24.81 |
November | 24.08 | 17.95 |
December | 22.54 | 11.71 |
Annual Sum or Average | 23.91 | 23.80 |
Minimum of Months | 22.54 | 11.71 |
Maximum of Months | 24.43 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F8 S1 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.01 | 13.01 |
February | 24.02 | 15.66 |
March | 24.10 | 17.34 |
April | 24.23 | 23.65 |
May | 24.35 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.41 | 33.82 |
September | 24.43 | 30.39 |
October | 24.41 | 24.81 |
November | 24.36 | 17.95 |
December | 23.97 | 11.71 |
Annual Sum or Average | 24.26 | 23.80 |
Minimum of Months | 23.97 | 11.71 |
Maximum of Months | 24.43 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F8 S2 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.01 | 13.01 |
February | 24.02 | 15.66 |
March | 24.10 | 17.34 |
April | 24.23 | 23.65 |
May | 24.35 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.41 | 33.82 |
September | 24.43 | 30.39 |
October | 24.41 | 24.81 |
November | 24.36 | 17.95 |
December | 23.96 | 11.71 |
Annual Sum or Average | 24.26 | 23.80 |
Minimum of Months | 23.96 | 11.71 |
Maximum of Months | 24.43 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F8 CORRIDOR
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.42 | 13.01 |
February | 24.90 | 15.66 |
March | 25.47 | 17.34 |
April | 26.11 | 23.65 |
May | 26.61 | 27.29 |
June | 27.17 | 33.99 |
July | 27.29 | 35.56 |
August | 27.13 | 33.82 |
September | 26.91 | 30.39 |
October | 26.43 | 24.81 |
November | 25.75 | 17.95 |
December | 24.22 | 11.71 |
Annual Sum or Average | 26.04 | 23.80 |
Minimum of Months | 24.22 | 11.71 |
Maximum of Months | 27.29 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F9 SW APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.72 | 13.01 |
February | 23.85 | 15.66 |
March | 24.05 | 17.34 |
April | 24.19 | 23.65 |
May | 24.36 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.41 | 33.82 |
September | 24.41 | 30.39 |
October | 24.38 | 24.81 |
November | 24.33 | 17.95 |
December | 23.63 | 11.71 |
Annual Sum or Average | 24.18 | 23.80 |
Minimum of Months | 23.63 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F9 NW APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.78 | 13.01 |
February | 23.36 | 15.66 |
March | 23.85 | 17.34 |
April | 24.12 | 23.65 |
May | 24.36 | 27.29 |
June | 24.41 | 33.99 |
July | 24.42 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.35 | 24.81 |
November | 24.06 | 17.95 |
December | 22.58 | 11.71 |
Annual Sum or Average | 23.92 | 23.80 |
Minimum of Months | 22.58 | 11.71 |
Maximum of Months | 24.42 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F9 SE APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.64 | 13.01 |
February | 23.83 | 15.66 |
March | 24.03 | 17.34 |
April | 24.21 | 23.65 |
May | 24.37 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.38 | 24.81 |
November | 24.31 | 17.95 |
December | 23.57 | 11.71 |
Annual Sum or Average | 24.16 | 23.80 |
Minimum of Months | 23.57 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F9 NE APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.62 | 13.01 |
February | 23.29 | 15.66 |
March | 23.83 | 17.34 |
April | 24.15 | 23.65 |
May | 24.37 | 27.29 |
June | 24.40 | 33.99 |
July | 24.42 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.36 | 24.81 |
November | 24.07 | 17.95 |
December | 22.44 | 11.71 |
Annual Sum or Average | 23.89 | 23.80 |
Minimum of Months | 22.44 | 11.71 |
Maximum of Months | 24.42 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F9 N1 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.69 | 13.01 |
February | 23.30 | 15.66 |
March | 23.79 | 17.34 |
April | 24.12 | 23.65 |
May | 24.35 | 27.29 |
June | 24.41 | 33.99 |
July | 24.43 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.35 | 24.81 |
November | 24.05 | 17.95 |
December | 22.50 | 11.71 |
Annual Sum or Average | 23.90 | 23.80 |
Minimum of Months | 22.50 | 11.71 |
Maximum of Months | 24.43 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F9 N2 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.68 | 13.01 |
February | 23.29 | 15.66 |
March | 23.78 | 17.34 |
April | 24.12 | 23.65 |
May | 24.35 | 27.29 |
June | 24.41 | 33.99 |
July | 24.43 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.35 | 24.81 |
November | 24.05 | 17.95 |
December | 22.49 | 11.71 |
Annual Sum or Average | 23.90 | 23.80 |
Minimum of Months | 22.49 | 11.71 |
Maximum of Months | 24.43 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F9 S1 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.93 | 13.01 |
February | 23.98 | 15.66 |
March | 24.07 | 17.34 |
April | 24.21 | 23.65 |
May | 24.35 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.41 | 33.82 |
September | 24.42 | 30.39 |
October | 24.40 | 24.81 |
November | 24.35 | 17.95 |
December | 23.89 | 11.71 |
Annual Sum or Average | 24.24 | 23.80 |
Minimum of Months | 23.89 | 11.71 |
Maximum of Months | 24.42 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F9 S2 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.93 | 13.01 |
February | 23.97 | 15.66 |
March | 24.07 | 17.34 |
April | 24.21 | 23.65 |
May | 24.35 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.41 | 33.82 |
September | 24.42 | 30.39 |
October | 24.40 | 24.81 |
November | 24.35 | 17.95 |
December | 23.88 | 11.71 |
Annual Sum or Average | 24.24 | 23.80 |
Minimum of Months | 23.88 | 11.71 |
Maximum of Months | 24.42 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: F9 CORRIDOR
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.29 | 13.01 |
February | 24.85 | 15.66 |
March | 25.46 | 17.34 |
April | 26.17 | 23.65 |
May | 26.72 | 27.29 |
June | 27.35 | 33.99 |
July | 27.48 | 35.56 |
August | 27.30 | 33.82 |
September | 27.04 | 30.39 |
October | 26.49 | 24.81 |
November | 25.71 | 17.95 |
December | 24.09 | 11.71 |
Annual Sum or Average | 26.08 | 23.80 |
Minimum of Months | 24.09 | 11.71 |
Maximum of Months | 27.48 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.35 | 13.01 |
February | 23.64 | 15.66 |
March | 23.90 | 17.34 |
April | 24.11 | 23.65 |
May | 24.33 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.34 | 24.81 |
November | 24.13 | 17.95 |
December | 23.29 | 11.71 |
Annual Sum or Average | 24.06 | 23.80 |
Minimum of Months | 23.29 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.72 | 13.01 |
February | 23.29 | 15.66 |
March | 23.72 | 17.34 |
April | 24.07 | 23.65 |
May | 24.34 | 27.29 |
June | 24.41 | 33.99 |
July | 24.41 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.29 | 24.81 |
November | 23.84 | 17.95 |
December | 22.61 | 11.71 |
Annual Sum or Average | 23.88 | 23.80 |
Minimum of Months | 22.61 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.29 | 13.01 |
February | 23.61 | 15.66 |
March | 23.88 | 17.34 |
April | 24.15 | 23.65 |
May | 24.35 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.34 | 24.81 |
November | 24.10 | 17.95 |
December | 23.25 | 11.71 |
Annual Sum or Average | 24.05 | 23.80 |
Minimum of Months | 23.25 | 11.71 |
Maximum of Months | 24.40 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.59 | 13.01 |
February | 23.25 | 15.66 |
March | 23.71 | 17.34 |
April | 24.10 | 23.65 |
May | 24.34 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.30 | 24.81 |
November | 23.85 | 17.95 |
December | 22.49 | 11.71 |
Annual Sum or Average | 23.85 | 23.80 |
Minimum of Months | 22.49 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.61 | 13.01 |
February | 23.25 | 15.66 |
March | 23.69 | 17.34 |
April | 24.07 | 23.65 |
May | 24.33 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.29 | 24.81 |
November | 23.84 | 17.95 |
December | 22.50 | 11.71 |
Annual Sum or Average | 23.85 | 23.80 |
Minimum of Months | 22.50 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.60 | 13.01 |
February | 23.25 | 15.66 |
March | 23.69 | 17.34 |
April | 24.07 | 23.65 |
May | 24.33 | 27.29 |
June | 24.40 | 33.99 |
July | 24.41 | 35.56 |
August | 24.40 | 33.82 |
September | 24.40 | 30.39 |
October | 24.29 | 24.81 |
November | 23.84 | 17.95 |
December | 22.50 | 11.71 |
Annual Sum or Average | 23.85 | 23.80 |
Minimum of Months | 22.50 | 11.71 |
Maximum of Months | 24.41 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.52 | 13.01 |
February | 23.76 | 15.66 |
March | 23.95 | 17.34 |
April | 24.15 | 23.65 |
May | 24.33 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.40 | 33.82 |
September | 24.42 | 30.39 |
October | 24.36 | 24.81 |
November | 24.20 | 17.95 |
December | 23.47 | 11.71 |
Annual Sum or Average | 24.11 | 23.80 |
Minimum of Months | 23.47 | 11.71 |
Maximum of Months | 24.42 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.52 | 13.01 |
February | 23.76 | 15.66 |
March | 23.95 | 17.34 |
April | 24.15 | 23.65 |
May | 24.33 | 27.29 |
June | 24.40 | 33.99 |
July | 24.40 | 35.56 |
August | 24.40 | 33.82 |
September | 24.42 | 30.39 |
October | 24.36 | 24.81 |
November | 24.20 | 17.95 |
December | 23.47 | 11.71 |
Annual Sum or Average | 24.11 | 23.80 |
Minimum of Months | 23.47 | 11.71 |
Maximum of Months | 24.42 | 35.56 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2015-09-09 19:11:36
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.48 | 13.01 |
February | 25.27 | 15.66 |
March | 25.94 | 17.34 |
April | 26.96 | 23.65 |
May | 27.68 | 27.29 |
June | 28.57 | 33.99 |
July | 28.75 | 35.56 |
August | 28.48 | 33.82 |
September | 28.08 | 30.39 |
October | 27.21 | 24.81 |
November | 26.07 | 17.95 |
December | 24.27 | 11.71 |
Annual Sum or Average | 26.82 | 23.80 |
Minimum of Months | 24.27 | 11.71 |
Maximum of Months | 28.75 | 35.56 |
Report: COMPONENTS OF PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2015-09-09 19:11:36
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W] | |
January | 0.241196E+12 | 145937.726 | 08-JAN-17:15 | 11327.174 | 57042.023 | 28046.477 | 0.000 | 43241.134 | 0.000 | 2563.967 | 1729.309 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
February | 0.232823E+12 | 167347.617 | 28-FEB-17:15 | 11327.174 | 57142.088 | 28046.477 | 0.000 | 63981.842 | 0.000 | 2563.967 | 2290.872 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
March | 0.266976E+12 | 166622.549 | 16-MAR-17:15 | 13120.457 | 57042.023 | 28046.477 | 0.000 | 61747.903 | 0.000 | 2563.967 | 2113.909 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
April | 0.298852E+12 | 181388.948 | 26-APR-16:15 | 11327.174 | 57142.088 | 28046.477 | 0.000 | 77565.281 | 0.000 | 2563.967 | 2748.764 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
May | 0.334733E+12 | 191999.658 | 14-MAY-17:15 | 13120.457 | 57042.023 | 28046.477 | 0.000 | 86442.776 | 0.000 | 2563.967 | 2796.146 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
June | 0.373347E+12 | 193779.397 | 12-JUN-17:15 | 13120.457 | 57042.023 | 28046.477 | 0.000 | 88075.672 | 0.000 | 2563.967 | 2942.989 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
July | 0.407442E+12 | 197190.806 | 07-JUL-17:00 | 13120.457 | 57042.023 | 28046.477 | 0.000 | 90743.738 | 0.000 | 2563.967 | 3686.135 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.394567E+12 | 197154.594 | 01-AUG-17:00 | 13120.457 | 57042.023 | 28046.477 | 0.000 | 90573.634 | 0.000 | 2563.967 | 3820.027 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.356808E+12 | 189759.302 | 10-SEP-16:15 | 11327.174 | 57042.023 | 28046.477 | 0.000 | 85879.778 | 0.000 | 2563.967 | 2912.240 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
October | 0.324937E+12 | 186341.197 | 02-OCT-16:15 | 11327.174 | 57142.088 | 28046.477 | 0.000 | 82347.714 | 0.000 | 2563.967 | 2918.580 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
November | 0.261721E+12 | 164735.079 | 05-NOV-16:15 | 11327.174 | 57042.023 | 28046.477 | 0.000 | 61624.792 | 0.000 | 2563.967 | 2143.004 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
December | 0.241119E+12 | 132881.932 | 02-DEC-17:30 | 11327.174 | 57042.023 | 28046.477 | 0.000 | 20639.427 | 10364.000 | 2563.967 | 911.052 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.373452E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||||
Minimum of Months | 0.232823E+12 | 132881.932 | 11327.174 | 57042.023 | 28046.477 | 0.000 | 20639.427 | 0.000 | 2563.967 | 911.052 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.407442E+12 | 197190.806 | 13120.457 | 57142.088 | 28046.477 | 0.000 | 90743.738 | 10364.000 | 2563.967 | 3820.027 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: COMPONENTS OF PEAK GAS DEMAND
For: Meter
Timestamp: 2015-09-09 19:11:36
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC [Invalid/Undefined] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT {AT MAX/MIN} [W] | WATERSYSTEMS:GAS {AT MAX/MIN} [W] | WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.889117E+11 | 117165.608 | 31-JAN-07:15 | 0.000 | 0.000 | 0.000 | 117165.608 | 73617.433 | 73617.433 | 43548.175 |
February | 0.821011E+11 | 130830.560 | 10-FEB-07:15 | 0.000 | 0.000 | 0.000 | 130830.560 | 73455.301 | 73455.301 | 57375.259 |
March | 0.844187E+11 | 98778.075 | 07-MAR-06:30 | 0.000 | 0.000 | 0.000 | 98778.075 | 69944.268 | 69944.268 | 28833.807 |
April | 0.722719E+11 | 71382.941 | 01-APR-06:00 | 0.000 | 0.000 | 0.000 | 71382.941 | 71382.941 | 71382.941 | 0.000 |
May | 0.665056E+11 | 68986.286 | 02-MAY-06:00 | 0.000 | 0.000 | 0.000 | 68986.286 | 68986.286 | 68986.286 | 0.000 |
June | 0.580560E+11 | 66867.905 | 03-JUN-06:00 | 0.000 | 0.000 | 0.000 | 66867.905 | 66867.905 | 66867.905 | 0.000 |
July | 0.569233E+11 | 65634.106 | 05-JUL-06:45 | 0.000 | 0.000 | 0.000 | 65634.106 | 65634.106 | 65634.106 | 0.000 |
August | 0.581141E+11 | 66040.223 | 26-AUG-06:30 | 0.000 | 0.000 | 0.000 | 66040.223 | 66040.223 | 66040.223 | 0.000 |
September | 0.612736E+11 | 67884.178 | 28-SEP-06:45 | 0.000 | 0.000 | 0.000 | 67884.178 | 67884.178 | 67884.178 | 0.000 |
October | 0.709808E+11 | 70383.196 | 31-OCT-06:00 | 0.000 | 0.000 | 0.000 | 70383.196 | 70383.196 | 70383.196 | 0.000 |
November | 0.765793E+11 | 72619.736 | 30-NOV-07:00 | 0.000 | 0.000 | 0.000 | 72619.736 | 72619.736 | 72619.736 | 0.000 |
December | 0.870762E+11 | 96266.332 | 16-DEC-06:45 | 0.000 | 0.000 | 0.000 | 96266.332 | 71686.849 | 71686.849 | 24579.482 |
Annual Sum or Average | 0.863212E+12 | 0.000 | 0.000 | 0.000 | ||||||
Minimum of Months | 0.569233E+11 | 65634.106 | 0.000 | 0.000 | 0.000 | 65634.106 | 65634.106 | 65634.106 | 0.000 | |
Maximum of Months | 0.889117E+11 | 130830.560 | 0.000 | 0.000 | 0.000 | 130830.560 | 73617.433 | 73617.433 | 57375.259 |