Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 19:10

Tabular Output Report in Format: HTML

Building: High-Rise Apartment

Environment: Phoenix Sky Harbor Intl Ap AZ USA TMY3 WMO#=722780

Simulation Timestamp: 2015-09-09 19:11:36


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:36

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 4597.73 586.71 651.25
Net Site Energy 4597.73 586.71 651.25
Total Source Energy 12762.95 1628.66 1807.81
Net Source Energy 12762.95 1628.66 1807.81


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 7836.48
Net Conditioned Building Area 7059.89
Unconditioned Building Area 776.58


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 8.14 7.22 0.00 0.00 0.00 0.00
Cooling 1085.41 0.00 0.00 0.00 0.00 0.00
Interior Lighting 296.56 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 162.75 0.00 0.00 0.00 0.00 0.00
Interior Equipment 1137.32 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 884.47 0.00 0.00 0.00 0.00 0.00
Pumps 79.58 0.00 0.00 0.00 0.00 0.00
Heat Rejection 44.12 0.00 0.00 0.00 0.00 4165.15
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 855.99 0.00 0.00 0.00 4778.51
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 3734.52 863.21 0.00 0.00 0.00 8943.67
Note: Electricity appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating Boiler 0.00 7.22 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
  Other 8.14 0.00 0.00 0.00 0.00 0.00
Cooling General 1085.41 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 242.55 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 54.01 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 162.75 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 1137.32 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 884.47 0.00 0.00 0.00 0.00 0.00
Pumps General 79.58 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 44.12 0.00 0.00 0.00 0.00 4165.15
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 855.99 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 4778.51
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 65.06 0.00 0.00 0.00 0.00 0.00
HVAC 297.70 122.27 0.00 0.00 0.00 1.27
Other 161.10 0.00 0.00 0.00 0.00 0.00
Total 528.98 122.27 0.00 0.00 0.00 1.27


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 58.61 0.00 0.00 0.00 0.00 0.00
HVAC 268.20 110.15 0.00 0.00 0.00 1.14
Other 145.13 0.00 0.00 0.00 0.00 0.00
Total 476.56 110.15 0.00 0.00 0.00 1.14


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 3734.52 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 3734.52 100.00
     
Total On-Site and Utility Electric Sources 3734.52 100.00
Total Electricity End Uses 3734.52 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 8943.67 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 8943.67 100.00
Total Water End Uses 8943.67 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 11.25
Time Setpoint Not Met During Occupied Cooling 362.25
Time Not Comfortable Based on Simple ASHRAE 55-2004 175.25


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |

COMPONENTS OF PEAK ELECTRICAL DEMAND

| Meter |

COMPONENTS OF PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:36

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 19:10
RunPeriod Phoenix Sky Harbor Intl Ap AZ USA TMY3 WMO#=722780
Weather File Phoenix Sky Harbor Intl Ap AZ USA TMY3 WMO#=722780
Latitude [deg] 33.45
Longitude [deg] -112.0
Elevation [m] 337.00
Time Zone -7.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3855.02 1411.96 515.55 1411.96 515.55
Window Opening Area [m2] 1150.39 423.59 152.73 423.59 150.48
Window-Wall Ratio [%] 29.84 30.00 29.62 30.00 29.19


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3752.84 1411.96 464.46 1411.96 464.46
Window Opening Area [m2] 1125.85 423.59 139.34 423.59 139.34
Window-Wall Ratio [%] 30.00 30.00 30.00 30.00 30.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
OFFICE 88.25 Yes Yes 268.96 1.00 58.52 17.56 29.5362 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 4.47 6.7128   0.0000
F2 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F3 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F4 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
M SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
M CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 13.4255   0.0000
F6 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F7 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F8 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F9 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
T SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   264.3872
Total 7836.48     23884.04   3855.02 1150.39 4.3335 39.48 8.6291
Conditioned Total 7059.89     21517.16   3752.84 1125.85 3.9979 35.57 6.6700
Unconditioned Total 776.58     2366.87   102.18 24.54 7.3840   26.4387
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:36

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 07-JUL-17:00 10-FEB-07:15 - - - 16-JUL-17:00
Heating 0.00 57375.26 0.00 0.00 0.00 0.00
Cooling 90743.74 0.00 0.00 0.00 0.00 0.00
Interior Lighting 13120.46 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 57042.02 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 28046.48 0.00 0.00 0.00 0.00 0.00
Pumps 2563.97 0.00 0.00 0.00 0.00 0.00
Heat Rejection 3686.14 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 73455.30 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 197190.81 130830.56 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating Boiler 0.00 57375.26 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 90743.74 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 10541.04 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 2579.42 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 57042.02 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 28046.48 0.00 0.00 0.00 0.00 0.00
Pumps General 2563.97 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 3686.14 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 73455.30 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:36

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 25.77 7.83 0.00 0.00 0.00
Cooling 3437.49 0.00 0.00 0.00 0.00
Interior Lighting 939.20 0.00 0.00 0.00 0.00
Exterior Lighting 515.42 0.00 0.00 0.00 0.00
Interior Equipment 3601.91 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 2801.13 0.00 0.00 0.00 0.00
Pumps 252.02 0.00 0.00 0.00 0.00
Heat Rejection 139.73 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 927.90 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 11827.23 935.72 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 3.65 1.11 0.00 0.00 0.00
Cooling 486.90 0.00 0.00 0.00 0.00
Interior Lighting 133.03 0.00 0.00 0.00 0.00
Exterior Lighting 73.01 0.00 0.00 0.00 0.00
Interior Equipment 510.19 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 396.77 0.00 0.00 0.00 0.00
Pumps 35.70 0.00 0.00 0.00 0.00
Heat Rejection 19.79 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 131.43 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1675.27 132.54 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 3.65 1.11 0.00 0.00 0.00
Cooling 486.90 0.00 0.00 0.00 0.00
Interior Lighting 133.03 0.00 0.00 0.00 0.00
Exterior Lighting 73.01 0.00 0.00 0.00 0.00
Interior Equipment 510.19 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 396.77 0.00 0.00 0.00 0.00
Pumps 35.70 0.00 0.00 0.00 0.00
Heat Rejection 19.79 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 131.43 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1675.27 132.54 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:36

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 3.70 0.00 3.70 Wetbulb [C] 1.70 100.00
PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 43.40 12.00 21.10 Wetbulb [C] 4.10 260.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:36

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 270.00 180.00  
F2 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F2 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F2 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F2 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F2 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F2 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F3 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F3 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F3 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F3 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F3 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F3 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F4 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F4 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F4 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F4 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F4 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F4 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
M WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F6 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F6 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F6 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F6 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F6 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F6 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F7 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F7 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F7 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F7 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F7 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F7 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F8 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F8 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F8 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F8 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F8 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F8 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F9 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F9 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F9 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F9 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F9 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F9 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.30 0.269 0.283 77.66 0.00 0.00  


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G SWALL SWA 180.00 90.00 S
GWINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No G WWALL SWA 270.00 90.00 W
GWINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G NWALL NWA 0.00 90.00 N
GWINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No G WWALL NWA 270.00 90.00 W
GWINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G SWALL SEA 180.00 90.00 S
GWINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No G EWALL SEA 90.00 90.00 E
GWINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G NWALL NEA 0.00 90.00 N
GWINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No G EWALL NEA 90.00 90.00 E
GWINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G NWALL N1A 0.00 90.00 N
GWINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G NWALL N2A 0.00 90.00 N
GWINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G SWALL S1A 180.00 90.00 S
GWINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G SWALL S2A 180.00 90.00 S
GWINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No G WWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.72_SHGC_0.25 3.36 0.00 0.00 3.36 3.36 4.600 0.293 0.130     No G EWALL C 90.00 90.00 E
F2WINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F2 WWALL SWA 270.00 90.00 W
F2WINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 SWALL SWA 180.00 90.00 S
F2WINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 NWALL NWA 0.00 90.00 N
F2WINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F2 WWALL NWA 270.00 90.00 W
F2WINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F2 EWALL SEA 90.00 90.00 E
F2WINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 SWALL SEA 180.00 90.00 S
F2WINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 NWALL NEA 0.00 90.00 N
F2WINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F2 EWALL NEA 90.00 90.00 E
F2WINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 NWALL N1A 0.00 90.00 N
F2WINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 NWALL N2A 0.00 90.00 N
F2WINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 SWALL S1A 180.00 90.00 S
F2WINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 SWALL S2A 180.00 90.00 S
F2WINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F2 WWALL C 270.00 90.00 W
F2WINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F2 EWALL C 90.00 90.00 E
F3WINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F3 WWALL SWA 270.00 90.00 W
F3WINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 SWALL SWA 180.00 90.00 S
F3WINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 NWALL NWA 0.00 90.00 N
F3WINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F3 WWALL NWA 270.00 90.00 W
F3WINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F3 EWALL SEA 90.00 90.00 E
F3WINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 SWALL SEA 180.00 90.00 S
F3WINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 NWALL NEA 0.00 90.00 N
F3WINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F3 EWALL NEA 90.00 90.00 E
F3WINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 NWALL N1A 0.00 90.00 N
F3WINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 NWALL N2A 0.00 90.00 N
F3WINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 SWALL S1A 180.00 90.00 S
F3WINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 SWALL S2A 180.00 90.00 S
F3WINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F3 WWALL C 270.00 90.00 W
F3WINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F3 EWALL C 90.00 90.00 E
F4WINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F4 WWALL SWA 270.00 90.00 W
F4WINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 SWALL SWA 180.00 90.00 S
F4WINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 NWALL NWA 0.00 90.00 N
F4WINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F4 WWALL NWA 270.00 90.00 W
F4WINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F4 EWALL SEA 90.00 90.00 E
F4WINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 SWALL SEA 180.00 90.00 S
F4WINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 NWALL NEA 0.00 90.00 N
F4WINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F4 EWALL NEA 90.00 90.00 E
F4WINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 NWALL N1A 0.00 90.00 N
F4WINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 NWALL N2A 0.00 90.00 N
F4WINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 SWALL S1A 180.00 90.00 S
F4WINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 SWALL S2A 180.00 90.00 S
F4WINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F4 WWALL C 270.00 90.00 W
F4WINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F4 EWALL C 90.00 90.00 E
MWINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No M WWALL SWA 270.00 90.00 W
MWINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M SWALL SWA 180.00 90.00 S
MWINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M NWALL NWA 0.00 90.00 N
MWINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No M WWALL NWA 270.00 90.00 W
MWINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No M EWALL SEA 90.00 90.00 E
MWINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M SWALL SEA 180.00 90.00 S
MWINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M NWALL NEA 0.00 90.00 N
MWINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No M EWALL NEA 90.00 90.00 E
MWINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M NWALL N1A 0.00 90.00 N
MWINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M NWALL N2A 0.00 90.00 N
MWINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M SWALL S1A 180.00 90.00 S
MWINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M SWALL S2A 180.00 90.00 S
MWINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No M WWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No M EWALL C 90.00 90.00 E
F6WINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F6 WWALL SWA 270.00 90.00 W
F6WINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 SWALL SWA 180.00 90.00 S
F6WINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 NWALL NWA 0.00 90.00 N
F6WINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F6 WWALL NWA 270.00 90.00 W
F6WINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F6 EWALL SEA 90.00 90.00 E
F6WINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 SWALL SEA 180.00 90.00 S
F6WINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 NWALL NEA 0.00 90.00 N
F6WINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F6 EWALL NEA 90.00 90.00 E
F6WINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 NWALL N1A 0.00 90.00 N
F6WINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 NWALL N2A 0.00 90.00 N
F6WINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 SWALL S1A 180.00 90.00 S
F6WINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 SWALL S2A 180.00 90.00 S
F6WINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F6 WWALL C 270.00 90.00 W
F6WINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F6 EWALL C 90.00 90.00 E
F7WINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F7 WWALL SWA 270.00 90.00 W
F7WINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 SWALL SWA 180.00 90.00 S
F7WINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 NWALL NWA 0.00 90.00 N
F7WINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F7 WWALL NWA 270.00 90.00 W
F7WINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F7 EWALL SEA 90.00 90.00 E
F7WINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 SWALL SEA 180.00 90.00 S
F7WINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 NWALL NEA 0.00 90.00 N
F7WINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F7 EWALL NEA 90.00 90.00 E
F7WINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 NWALL N1A 0.00 90.00 N
F7WINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 NWALL N2A 0.00 90.00 N
F7WINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 SWALL S1A 180.00 90.00 S
F7WINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 SWALL S2A 180.00 90.00 S
F7WINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F7 WWALL C 270.00 90.00 W
F7WINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F7 EWALL C 90.00 90.00 E
F8WINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F8 WWALL SWA 270.00 90.00 W
F8WINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 SWALL SWA 180.00 90.00 S
F8WINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 NWALL NWA 0.00 90.00 N
F8WINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F8 WWALL NWA 270.00 90.00 W
F8WINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F8 EWALL SEA 90.00 90.00 E
F8WINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 SWALL SEA 180.00 90.00 S
F8WINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 NWALL NEA 0.00 90.00 N
F8WINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F8 EWALL NEA 90.00 90.00 E
F8WINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 NWALL N1A 0.00 90.00 N
F8WINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 NWALL N2A 0.00 90.00 N
F8WINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 SWALL S1A 180.00 90.00 S
F8WINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 SWALL S2A 180.00 90.00 S
F8WINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F8 WWALL C 270.00 90.00 W
F8WINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F8 EWALL C 90.00 90.00 E
F9WINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F9 WWALL SWA 270.00 90.00 W
F9WINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 SWALL SWA 180.00 90.00 S
F9WINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 NWALL NWA 0.00 90.00 N
F9WINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F9 WWALL NWA 270.00 90.00 W
F9WINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F9 EWALL SEA 90.00 90.00 E
F9WINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 SWALL SEA 180.00 90.00 S
F9WINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 NWALL NEA 0.00 90.00 N
F9WINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F9 EWALL NEA 90.00 90.00 E
F9WINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 NWALL N1A 0.00 90.00 N
F9WINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 NWALL N2A 0.00 90.00 N
F9WINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 SWALL S1A 180.00 90.00 S
F9WINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 SWALL S2A 180.00 90.00 S
F9WINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F9 WWALL C 270.00 90.00 W
F9WINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F9 EWALL C 90.00 90.00 E
TWINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No T WWALL SWA 270.00 90.00 W
TWINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T SWALL SWA 180.00 90.00 S
TWINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T NWALL NWA 0.00 90.00 N
TWINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No T WWALL NWA 270.00 90.00 W
TWINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No T EWALL SEA 90.00 90.00 E
TWINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T SWALL SEA 180.00 90.00 S
TWINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T NWALL NEA 0.00 90.00 N
TWINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No T EWALL NEA 90.00 90.00 E
TWINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T NWALL N1A 0.00 90.00 N
TWINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T NWALL N2A 0.00 90.00 N
TWINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T SWALL S1A 180.00 90.00 S
TWINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T SWALL S2A 180.00 90.00 S
TWINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No T WWALL C 270.00 90.00 W
TWINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No T EWALL C 90.00 90.00 E
Total or Average           1150.39 4.600 0.293 0.130              
North Total or Average           423.59 4.600 0.293 0.130              
Non-North Total or Average           726.80 4.600 0.293 0.130              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:36

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW3 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
GWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW4 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
GWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
GWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW5 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
GWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW9 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
GWINDOW10 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
GWINDOW11 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
GWINDOW12 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
GWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW3 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW4 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW1 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW5 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW9 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW10 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW11 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW12 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW3 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW4 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW1 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW5 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW9 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW10 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW11 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW12 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW3 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW4 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW1 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW5 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW9 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW10 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW11 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW12 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW3 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
MWINDOW4 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
MWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
MWINDOW5 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
MWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW9 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
MWINDOW10 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
MWINDOW11 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
MWINDOW12 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
MWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW3 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW4 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW1 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW5 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW9 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW10 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW11 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW12 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW3 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW4 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW1 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW5 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW9 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW10 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW11 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW12 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW3 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW4 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW1 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW5 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW9 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW10 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW11 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW12 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW3 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW4 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW1 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW5 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW9 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW10 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW11 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW12 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW3 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
TWINDOW4 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
TWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
TWINDOW5 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
TWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW9 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
TWINDOW10 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
TWINDOW11 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
TWINDOW12 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
TWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:36

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
G SW APARTMENT_LIGHTS_HARDWIRED G SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G NW APARTMENT_LIGHTS_HARDWIRED G NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
OFFICE_LIGHTS_HARDWIRED OFFICE 14.7681 88.25 1303.26 GeneralLights LTG_OFF_SCH 62.05 168.00 61.07 0.0000 Y 14.94
G NE APARTMENT_LIGHTS_HARDWIRED G NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G N1 APARTMENT_LIGHTS_HARDWIRED G N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G N2 APARTMENT_LIGHTS_HARDWIRED G N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G S1 APARTMENT_LIGHTS_HARDWIRED G S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G S2 APARTMENT_LIGHTS_HARDWIRED G S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G CORRIDOR_LIGHTS_HARDWIRED G CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F2 SW APARTMENT_LIGHTS_HARDWIRED F2 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 NW APARTMENT_LIGHTS_HARDWIRED F2 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 SE APARTMENT_LIGHTS_HARDWIRED F2 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 NE APARTMENT_LIGHTS_HARDWIRED F2 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 N1 APARTMENT_LIGHTS_HARDWIRED F2 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 N2 APARTMENT_LIGHTS_HARDWIRED F2 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 S1 APARTMENT_LIGHTS_HARDWIRED F2 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 S2 APARTMENT_LIGHTS_HARDWIRED F2 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 CORRIDOR_LIGHTS_HARDWIRED F2 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F3 SW APARTMENT_LIGHTS_HARDWIRED F3 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 NW APARTMENT_LIGHTS_HARDWIRED F3 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 SE APARTMENT_LIGHTS_HARDWIRED F3 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 NE APARTMENT_LIGHTS_HARDWIRED F3 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 N1 APARTMENT_LIGHTS_HARDWIRED F3 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 N2 APARTMENT_LIGHTS_HARDWIRED F3 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 S1 APARTMENT_LIGHTS_HARDWIRED F3 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 S2 APARTMENT_LIGHTS_HARDWIRED F3 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 CORRIDOR_LIGHTS_HARDWIRED F3 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F4 SW APARTMENT_LIGHTS_HARDWIRED F4 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 NW APARTMENT_LIGHTS_HARDWIRED F4 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 SE APARTMENT_LIGHTS_HARDWIRED F4 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 NE APARTMENT_LIGHTS_HARDWIRED F4 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 N1 APARTMENT_LIGHTS_HARDWIRED F4 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 N2 APARTMENT_LIGHTS_HARDWIRED F4 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 S1 APARTMENT_LIGHTS_HARDWIRED F4 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 S2 APARTMENT_LIGHTS_HARDWIRED F4 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 CORRIDOR_LIGHTS_HARDWIRED F4 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
M SW APARTMENT_LIGHTS_HARDWIRED M SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M NW APARTMENT_LIGHTS_HARDWIRED M NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M SE APARTMENT_LIGHTS_HARDWIRED M SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M NE APARTMENT_LIGHTS_HARDWIRED M NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M N1 APARTMENT_LIGHTS_HARDWIRED M N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M N2 APARTMENT_LIGHTS_HARDWIRED M N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M S1 APARTMENT_LIGHTS_HARDWIRED M S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M S2 APARTMENT_LIGHTS_HARDWIRED M S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M CORRIDOR_LIGHTS_HARDWIRED M CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F6 SW APARTMENT_LIGHTS_HARDWIRED F6 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 NW APARTMENT_LIGHTS_HARDWIRED F6 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 SE APARTMENT_LIGHTS_HARDWIRED F6 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 NE APARTMENT_LIGHTS_HARDWIRED F6 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 N1 APARTMENT_LIGHTS_HARDWIRED F6 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 N2 APARTMENT_LIGHTS_HARDWIRED F6 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 S1 APARTMENT_LIGHTS_HARDWIRED F6 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 S2 APARTMENT_LIGHTS_HARDWIRED F6 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 CORRIDOR_LIGHTS_HARDWIRED F6 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F7 SW APARTMENT_LIGHTS_HARDWIRED F7 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 NW APARTMENT_LIGHTS_HARDWIRED F7 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 SE APARTMENT_LIGHTS_HARDWIRED F7 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 NE APARTMENT_LIGHTS_HARDWIRED F7 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 N1 APARTMENT_LIGHTS_HARDWIRED F7 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 N2 APARTMENT_LIGHTS_HARDWIRED F7 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 S1 APARTMENT_LIGHTS_HARDWIRED F7 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 S2 APARTMENT_LIGHTS_HARDWIRED F7 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 CORRIDOR_LIGHTS_HARDWIRED F7 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F8 SW APARTMENT_LIGHTS_HARDWIRED F8 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 NW APARTMENT_LIGHTS_HARDWIRED F8 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 SE APARTMENT_LIGHTS_HARDWIRED F8 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 NE APARTMENT_LIGHTS_HARDWIRED F8 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 N1 APARTMENT_LIGHTS_HARDWIRED F8 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 N2 APARTMENT_LIGHTS_HARDWIRED F8 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 S1 APARTMENT_LIGHTS_HARDWIRED F8 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 S2 APARTMENT_LIGHTS_HARDWIRED F8 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 CORRIDOR_LIGHTS_HARDWIRED F8 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F9 SW APARTMENT_LIGHTS_HARDWIRED F9 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 NW APARTMENT_LIGHTS_HARDWIRED F9 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 SE APARTMENT_LIGHTS_HARDWIRED F9 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 NE APARTMENT_LIGHTS_HARDWIRED F9 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 N1 APARTMENT_LIGHTS_HARDWIRED F9 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 N2 APARTMENT_LIGHTS_HARDWIRED F9 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 S1 APARTMENT_LIGHTS_HARDWIRED F9 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 S2 APARTMENT_LIGHTS_HARDWIRED F9 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 CORRIDOR_LIGHTS_HARDWIRED F9 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
T SW APARTMENT_LIGHTS_HARDWIRED T SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T NW APARTMENT_LIGHTS_HARDWIRED T NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T SE APARTMENT_LIGHTS_HARDWIRED T SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T NE APARTMENT_LIGHTS_HARDWIRED T NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T N1 APARTMENT_LIGHTS_HARDWIRED T N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T N2 APARTMENT_LIGHTS_HARDWIRED T N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T S1 APARTMENT_LIGHTS_HARDWIRED T S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T S2 APARTMENT_LIGHTS_HARDWIRED T S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T CORRIDOR_LIGHTS_HARDWIRED T CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
G SW APARTMENT_LIGHTS_PLUGIN G SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G NW APARTMENT_LIGHTS_PLUGIN G NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
OFFICE_LIGHTS_PLUGIN OFFICE 14.7681 88.25 1303.26 GeneralLights-plugin LTG_OFF_SCH 62.05 168.00 61.07 0.0000 Y 14.94
G NE APARTMENT_LIGHTS_PLUGIN G NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G N1 APARTMENT_LIGHTS_PLUGIN G N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G N2 APARTMENT_LIGHTS_PLUGIN G N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G S1 APARTMENT_LIGHTS_PLUGIN G S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G S2 APARTMENT_LIGHTS_PLUGIN G S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 SW APARTMENT_LIGHTS_PLUGIN F2 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 NW APARTMENT_LIGHTS_PLUGIN F2 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 SE APARTMENT_LIGHTS_PLUGIN F2 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 NE APARTMENT_LIGHTS_PLUGIN F2 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 N1 APARTMENT_LIGHTS_PLUGIN F2 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 N2 APARTMENT_LIGHTS_PLUGIN F2 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 S1 APARTMENT_LIGHTS_PLUGIN F2 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 S2 APARTMENT_LIGHTS_PLUGIN F2 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 SW APARTMENT_LIGHTS_PLUGIN F3 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 NW APARTMENT_LIGHTS_PLUGIN F3 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 SE APARTMENT_LIGHTS_PLUGIN F3 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 NE APARTMENT_LIGHTS_PLUGIN F3 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 N1 APARTMENT_LIGHTS_PLUGIN F3 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 N2 APARTMENT_LIGHTS_PLUGIN F3 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 S1 APARTMENT_LIGHTS_PLUGIN F3 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 S2 APARTMENT_LIGHTS_PLUGIN F3 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 SW APARTMENT_LIGHTS_PLUGIN F4 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 NW APARTMENT_LIGHTS_PLUGIN F4 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 SE APARTMENT_LIGHTS_PLUGIN F4 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 NE APARTMENT_LIGHTS_PLUGIN F4 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 N1 APARTMENT_LIGHTS_PLUGIN F4 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 N2 APARTMENT_LIGHTS_PLUGIN F4 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 S1 APARTMENT_LIGHTS_PLUGIN F4 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 S2 APARTMENT_LIGHTS_PLUGIN F4 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M SW APARTMENT_LIGHTS_PLUGIN M SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M NW APARTMENT_LIGHTS_PLUGIN M NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M SE APARTMENT_LIGHTS_PLUGIN M SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M NE APARTMENT_LIGHTS_PLUGIN M NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M N1 APARTMENT_LIGHTS_PLUGIN M N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M N2 APARTMENT_LIGHTS_PLUGIN M N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M S1 APARTMENT_LIGHTS_PLUGIN M S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M S2 APARTMENT_LIGHTS_PLUGIN M S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M CORRIDOR_LIGHTS_PLUGIN M CORRIDOR 6.7128 77.66 521.30 GeneralLights-plugin LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F6 SW APARTMENT_LIGHTS_PLUGIN F6 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 NW APARTMENT_LIGHTS_PLUGIN F6 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 SE APARTMENT_LIGHTS_PLUGIN F6 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 NE APARTMENT_LIGHTS_PLUGIN F6 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 N1 APARTMENT_LIGHTS_PLUGIN F6 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 N2 APARTMENT_LIGHTS_PLUGIN F6 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 S1 APARTMENT_LIGHTS_PLUGIN F6 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 S2 APARTMENT_LIGHTS_PLUGIN F6 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 SW APARTMENT_LIGHTS_PLUGIN F7 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 NW APARTMENT_LIGHTS_PLUGIN F7 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 SE APARTMENT_LIGHTS_PLUGIN F7 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 NE APARTMENT_LIGHTS_PLUGIN F7 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 N1 APARTMENT_LIGHTS_PLUGIN F7 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 N2 APARTMENT_LIGHTS_PLUGIN F7 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 S1 APARTMENT_LIGHTS_PLUGIN F7 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 S2 APARTMENT_LIGHTS_PLUGIN F7 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 SW APARTMENT_LIGHTS_PLUGIN F8 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 NW APARTMENT_LIGHTS_PLUGIN F8 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 SE APARTMENT_LIGHTS_PLUGIN F8 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 NE APARTMENT_LIGHTS_PLUGIN F8 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 N1 APARTMENT_LIGHTS_PLUGIN F8 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 N2 APARTMENT_LIGHTS_PLUGIN F8 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 S1 APARTMENT_LIGHTS_PLUGIN F8 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 S2 APARTMENT_LIGHTS_PLUGIN F8 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 SW APARTMENT_LIGHTS_PLUGIN F9 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 NW APARTMENT_LIGHTS_PLUGIN F9 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 SE APARTMENT_LIGHTS_PLUGIN F9 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 NE APARTMENT_LIGHTS_PLUGIN F9 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 N1 APARTMENT_LIGHTS_PLUGIN F9 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 N2 APARTMENT_LIGHTS_PLUGIN F9 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 S1 APARTMENT_LIGHTS_PLUGIN F9 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 S2 APARTMENT_LIGHTS_PLUGIN F9 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T SW APARTMENT_LIGHTS_PLUGIN T SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T NW APARTMENT_LIGHTS_PLUGIN T NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T SE APARTMENT_LIGHTS_PLUGIN T SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T NE APARTMENT_LIGHTS_PLUGIN T NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T N1 APARTMENT_LIGHTS_PLUGIN T N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T N2 APARTMENT_LIGHTS_PLUGIN T N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T S1 APARTMENT_LIGHTS_PLUGIN T S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T S2 APARTMENT_LIGHTS_PLUGIN T S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
Interior Lighting Total   2.2679 14974.03 33959.19               296.56


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 10364.00 AstronomicalClock -   83.65 83.65 162.75
Exterior Lighting Total 10364.00           162.75



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:36

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
CENTRAL BOILER Boiler:HotWater 363812.06 0.75    
CENTRAL TOWER EvaporativeFluidCooler:SingleSpeed 291049.65      


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
HEAT PUMP COOLING MODE AIRLOOP G SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4944.70 3594.30 1350.41 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4819.86 3505.73 1314.14 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP OFFICE Coil:Cooling:WaterToAirHeatPump:EquationFit   6484.99 4721.09 1763.90 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4053.52 2947.75 1105.77 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2825.99 2004.98 821.01 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2811.26 1993.91 817.35 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3153.41 2230.14 923.26 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3235.37 2292.13 943.24 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5631.45 4118.89 1512.56 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5494.17 4018.91 1475.26 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   5311.55 3887.58 1423.97 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4678.02 3420.19 1257.83 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3207.74 2296.47 911.27 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3196.33 2287.88 908.45 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3596.21 2568.45 1027.77 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3622.42 2588.24 1034.18 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5656.23 4141.34 1514.89 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5521.67 4043.39 1478.28 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   5071.97 3711.05 1360.92 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4725.41 3459.59 1265.82 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3241.26 2323.92 917.34 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3230.10 2315.52 914.58 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3628.31 2594.88 1033.43 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3638.75 2602.76 1035.99 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5700.68 4177.63 1523.05 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5565.27 4079.01 1486.26 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   5089.00 3726.67 1362.33 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4769.53 3495.59 1273.94 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3282.13 2356.35 925.78 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3271.14 2348.07 923.07 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3664.24 2623.66 1040.59 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3672.38 2629.80 1042.58 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5775.51 4234.89 1540.62 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5636.05 4135.48 1500.57 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SE Coil:Cooling:WaterToAirHeatPump:EquationFit   5154.81 3778.50 1376.32 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4838.72 3549.95 1288.77 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3347.39 2406.82 940.56 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3336.53 2398.65 937.88 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3724.95 2670.84 1054.11 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3732.74 2676.72 1056.02 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5763.95 4228.17 1535.78 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5622.84 4127.52 1495.32 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   5142.86 3771.43 1371.42 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4825.97 3542.27 1283.70 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3332.42 2396.71 935.71 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3321.73 2388.66 933.07 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3712.36 2661.02 1051.34 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3715.54 2664.88 1050.67 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5778.07 4240.53 1537.54 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5636.58 4139.60 1496.98 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   5156.79 3783.62 1373.16 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4854.16 3561.09 1293.07 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3352.76 2410.75 942.02 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3342.47 2402.99 939.48 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3721.41 2668.85 1052.55 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3724.14 2672.37 1051.77 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5811.70 4267.40 1544.30 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5670.12 4166.39 1503.73 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   5189.65 3809.90 1379.76 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4888.03 3588.11 1299.92 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3384.35 2435.45 948.90 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3374.18 2427.78 946.39 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3749.74 2691.16 1058.59 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3756.44 2696.21 1060.23 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5986.62 4401.83 1584.80 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5854.40 4306.46 1547.94 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   5321.03 3907.51 1413.53 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   5005.45 3677.95 1327.50 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3544.48 2559.13 985.35 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3542.93 2555.77 987.16 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3884.62 2793.86 1090.77 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3892.07 2799.47 1092.59 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SW Coil:Cooling:WaterToAirHeatPump:EquationFit   7202.93 5313.14 1889.79 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NW Coil:Cooling:WaterToAirHeatPump:EquationFit   6988.79 5155.84 1832.95 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SE Coil:Cooling:WaterToAirHeatPump:EquationFit   6515.69 4791.43 1724.26 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NE Coil:Cooling:WaterToAirHeatPump:EquationFit   5962.26 4396.91 1565.34 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   4594.55 3330.19 1264.36 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   4592.76 3328.85 1263.91 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   5091.20 3704.44 1386.76 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   5098.39 3709.85 1388.53 0.73 0.00    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
None            


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
HEAT PUMP HEATING MODE AIRLOOP G SW Coil:Heating:WaterToAirHeatPump:EquationFit   4944.70 0.00
HEAT PUMP HEATING MODE AIRLOOP G NW Coil:Heating:WaterToAirHeatPump:EquationFit   4819.86 0.00
HEAT PUMP HEATING MODE AIRLOOP OFFICE Coil:Heating:WaterToAirHeatPump:EquationFit   6484.99 0.00
HEAT PUMP HEATING MODE AIRLOOP G NE Coil:Heating:WaterToAirHeatPump:EquationFit   4053.52 0.00
HEAT PUMP HEATING MODE AIRLOOP G N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2825.99 0.00
HEAT PUMP HEATING MODE AIRLOOP G N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2811.26 0.00
HEAT PUMP HEATING MODE AIRLOOP G S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3153.41 0.00
HEAT PUMP HEATING MODE AIRLOOP G S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3235.37 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5631.45 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NW Coil:Heating:WaterToAirHeatPump:EquationFit   5494.17 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SE Coil:Heating:WaterToAirHeatPump:EquationFit   5311.55 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4678.02 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3207.74 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3196.33 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3596.21 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3622.42 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5656.23 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NW Coil:Heating:WaterToAirHeatPump:EquationFit   5521.67 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SE Coil:Heating:WaterToAirHeatPump:EquationFit   5071.97 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4725.41 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3241.26 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3230.10 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3628.31 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3638.75 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5700.68 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NW Coil:Heating:WaterToAirHeatPump:EquationFit   5565.27 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SE Coil:Heating:WaterToAirHeatPump:EquationFit   5089.00 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4769.53 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3282.13 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3271.14 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3664.24 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3672.38 0.00
HEAT PUMP HEATING MODE AIRLOOP M SW Coil:Heating:WaterToAirHeatPump:EquationFit   5775.51 0.00
HEAT PUMP HEATING MODE AIRLOOP M NW Coil:Heating:WaterToAirHeatPump:EquationFit   5636.05 0.00
HEAT PUMP HEATING MODE AIRLOOP M SE Coil:Heating:WaterToAirHeatPump:EquationFit   5154.81 0.00
HEAT PUMP HEATING MODE AIRLOOP M NE Coil:Heating:WaterToAirHeatPump:EquationFit   4838.72 0.00
HEAT PUMP HEATING MODE AIRLOOP M N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3347.39 0.00
HEAT PUMP HEATING MODE AIRLOOP M N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3336.53 0.00
HEAT PUMP HEATING MODE AIRLOOP M S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3724.95 0.00
HEAT PUMP HEATING MODE AIRLOOP M S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3732.74 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5763.95 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NW Coil:Heating:WaterToAirHeatPump:EquationFit   5622.84 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SE Coil:Heating:WaterToAirHeatPump:EquationFit   5142.86 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4825.97 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3332.42 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3321.73 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3712.36 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3715.54 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5778.07 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NW Coil:Heating:WaterToAirHeatPump:EquationFit   5636.58 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SE Coil:Heating:WaterToAirHeatPump:EquationFit   5156.79 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4854.16 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3352.76 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3342.47 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3721.41 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3724.14 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5811.70 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NW Coil:Heating:WaterToAirHeatPump:EquationFit   5670.12 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SE Coil:Heating:WaterToAirHeatPump:EquationFit   5189.65 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4888.03 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3384.35 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3374.18 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3749.74 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3756.44 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5986.62 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NW Coil:Heating:WaterToAirHeatPump:EquationFit   5854.40 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SE Coil:Heating:WaterToAirHeatPump:EquationFit   5321.03 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NE Coil:Heating:WaterToAirHeatPump:EquationFit   5005.45 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3544.48 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3542.93 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3884.62 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3892.07 0.00
HEAT PUMP HEATING MODE AIRLOOP T SW Coil:Heating:WaterToAirHeatPump:EquationFit   7202.93 0.00
HEAT PUMP HEATING MODE AIRLOOP T NW Coil:Heating:WaterToAirHeatPump:EquationFit   6988.79 0.00
HEAT PUMP HEATING MODE AIRLOOP T SE Coil:Heating:WaterToAirHeatPump:EquationFit   6515.69 0.00
HEAT PUMP HEATING MODE AIRLOOP T NE Coil:Heating:WaterToAirHeatPump:EquationFit   5962.26 0.00
HEAT PUMP HEATING MODE AIRLOOP T N1 Coil:Heating:WaterToAirHeatPump:EquationFit   4594.55 0.00
HEAT PUMP HEATING MODE AIRLOOP T N2 Coil:Heating:WaterToAirHeatPump:EquationFit   4592.76 0.00
HEAT PUMP HEATING MODE AIRLOOP T S1 Coil:Heating:WaterToAirHeatPump:EquationFit   5091.20 0.00
HEAT PUMP HEATING MODE AIRLOOP T S2 Coil:Heating:WaterToAirHeatPump:EquationFit   5098.39 0.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW Coil:Heating:Electric   1814.94 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW Coil:Heating:Electric   1816.25 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE Coil:Heating:Electric   2375.90 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE Coil:Heating:Electric   1811.69 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 Coil:Heating:Electric   1282.95 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 Coil:Heating:Electric   1282.88 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 Coil:Heating:Electric   1279.12 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 Coil:Heating:Electric   1285.25 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW Coil:Heating:Electric   1769.67 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW Coil:Heating:Electric   1770.54 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE Coil:Heating:Electric   1784.02 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE Coil:Heating:Electric   1765.38 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 Coil:Heating:Electric   1140.24 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 Coil:Heating:Electric   1140.15 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 Coil:Heating:Electric   1142.10 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 Coil:Heating:Electric   1143.42 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW Coil:Heating:Electric   1753.45 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW Coil:Heating:Electric   1754.10 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE Coil:Heating:Electric   1750.98 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE Coil:Heating:Electric   1749.20 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 Coil:Heating:Electric   1105.96 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 Coil:Heating:Electric   1105.87 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 Coil:Heating:Electric   1105.89 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 Coil:Heating:Electric   1106.06 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW Coil:Heating:Electric   1768.71 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW Coil:Heating:Electric   1769.66 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE Coil:Heating:Electric   1764.45 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE Coil:Heating:Electric   1765.11 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 Coil:Heating:Electric   1107.04 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 Coil:Heating:Electric   1106.96 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 Coil:Heating:Electric   1106.41 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 Coil:Heating:Electric   1106.36 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW Coil:Heating:Electric   1768.36 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW Coil:Heating:Electric   1768.46 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE Coil:Heating:Electric   1764.22 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE Coil:Heating:Electric   1764.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 Coil:Heating:Electric   1097.31 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 Coil:Heating:Electric   1097.23 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 Coil:Heating:Electric   1097.45 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 Coil:Heating:Electric   1097.38 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW Coil:Heating:Electric   1825.51 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW Coil:Heating:Electric   1826.44 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE Coil:Heating:Electric   1821.69 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE Coil:Heating:Electric   1822.62 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 Coil:Heating:Electric   1141.72 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 Coil:Heating:Electric   1141.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 Coil:Heating:Electric   1141.01 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 Coil:Heating:Electric   1140.95 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW Coil:Heating:Electric   1861.44 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW Coil:Heating:Electric   1862.16 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE Coil:Heating:Electric   1857.98 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE Coil:Heating:Electric   1858.69 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 Coil:Heating:Electric   1168.49 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 Coil:Heating:Electric   1168.43 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 Coil:Heating:Electric   1167.96 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 Coil:Heating:Electric   1167.90 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW Coil:Heating:Electric   1900.21 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW Coil:Heating:Electric   1900.58 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE Coil:Heating:Electric   1897.08 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE Coil:Heating:Electric   1897.46 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 Coil:Heating:Electric   1199.32 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 Coil:Heating:Electric   1199.26 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 Coil:Heating:Electric   1199.11 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 Coil:Heating:Electric   1199.05 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW Coil:Heating:Electric   2022.47 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW Coil:Heating:Electric   2021.10 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE Coil:Heating:Electric   2019.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE Coil:Heating:Electric   2018.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 Coil:Heating:Electric   1307.00 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 Coil:Heating:Electric   1306.95 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 Coil:Heating:Electric   1308.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 Coil:Heating:Electric   1308.23 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW Coil:Heating:Electric   2441.16 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW Coil:Heating:Electric   2443.61 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE Coil:Heating:Electric   2438.78 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE Coil:Heating:Electric   2441.23 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 Coil:Heating:Electric   1757.79 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 Coil:Heating:Electric   1757.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 Coil:Heating:Electric   1754.39 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 Coil:Heating:Electric   1754.35 1.00


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
AIRLOOP G SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.33 383.21 1160.84 1.00 General
AIRLOOP G NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 374.68 1160.84 1.00 General
AIRLOOP OFFICE SUPPLY FAN Fan:OnOff 0.54 622.50 0.43 503.22 1160.84 1.00 General
AIRLOOP G NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.27 313.86 1160.84 1.00 General
AIRLOOP G N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 206.73 1160.84 1.00 General
AIRLOOP G N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 205.49 1160.84 1.00 General
AIRLOOP G S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 228.12 1160.84 1.00 General
AIRLOOP G S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 235.07 1160.84 1.00 General
AIRLOOP F2 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.38 443.19 1160.84 1.00 General
AIRLOOP F2 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.37 433.07 1160.84 1.00 General
AIRLOOP F2 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.36 418.42 1160.84 1.00 General
AIRLOOP F2 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 367.00 1160.84 1.00 General
AIRLOOP F2 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 239.35 1160.84 1.00 General
AIRLOOP F2 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 238.38 1160.84 1.00 General
AIRLOOP F2 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 266.30 1160.84 1.00 General
AIRLOOP F2 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 268.53 1160.84 1.00 General
AIRLOOP F3 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.38 445.94 1160.84 1.00 General
AIRLOOP F3 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.38 436.05 1160.84 1.00 General
AIRLOOP F3 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.34 398.64 1160.84 1.00 General
AIRLOOP F3 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 371.66 1160.84 1.00 General
AIRLOOP F3 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 242.56 1160.84 1.00 General
AIRLOOP F3 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 241.61 1160.84 1.00 General
AIRLOOP F3 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 269.39 1160.84 1.00 General
AIRLOOP F3 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 270.28 1160.84 1.00 General
AIRLOOP F4 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.39 450.20 1160.84 1.00 General
AIRLOOP F4 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.38 440.23 1160.84 1.00 General
AIRLOOP F4 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.35 400.56 1160.84 1.00 General
AIRLOOP F4 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 375.88 1160.84 1.00 General
AIRLOOP F4 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 246.29 1160.84 1.00 General
AIRLOOP F4 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 245.36 1160.84 1.00 General
AIRLOOP F4 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 272.72 1160.84 1.00 General
AIRLOOP F4 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 273.41 1160.84 1.00 General
AIRLOOP M SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.39 456.51 1160.84 1.00 General
AIRLOOP M NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.38 446.51 1160.84 1.00 General
AIRLOOP M SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.35 406.55 1160.84 1.00 General
AIRLOOP M NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.33 382.16 1160.84 1.00 General
AIRLOOP M N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 252.05 1160.84 1.00 General
AIRLOOP M N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 251.13 1160.84 1.00 General
AIRLOOP M S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 278.10 1160.84 1.00 General
AIRLOOP M S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 278.76 1160.84 1.00 General
AIRLOOP F6 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.39 455.86 1160.84 1.00 General
AIRLOOP F6 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.38 445.72 1160.84 1.00 General
AIRLOOP F6 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.35 405.85 1160.84 1.00 General
AIRLOOP F6 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.33 381.39 1160.84 1.00 General
AIRLOOP F6 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 250.97 1160.84 1.00 General
AIRLOOP F6 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 250.07 1160.84 1.00 General
AIRLOOP F6 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 276.86 1160.84 1.00 General
AIRLOOP F6 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 277.49 1160.84 1.00 General
AIRLOOP F7 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.39 457.35 1160.84 1.00 General
AIRLOOP F7 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.39 447.18 1160.84 1.00 General
AIRLOOP F7 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.35 407.32 1160.84 1.00 General
AIRLOOP F7 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.33 382.97 1160.84 1.00 General
AIRLOOP F7 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 252.12 1160.84 1.00 General
AIRLOOP F7 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 251.24 1160.84 1.00 General
AIRLOOP F7 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 277.80 1160.84 1.00 General
AIRLOOP F7 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 278.39 1160.84 1.00 General
AIRLOOP F8 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.40 460.47 1160.84 1.00 General
AIRLOOP F8 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.39 450.30 1160.84 1.00 General
AIRLOOP F8 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.35 410.38 1160.84 1.00 General
AIRLOOP F8 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.33 386.11 1160.84 1.00 General
AIRLOOP F8 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 254.95 1160.84 1.00 General
AIRLOOP F8 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 254.08 1160.84 1.00 General
AIRLOOP F8 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 280.35 1160.84 1.00 General
AIRLOOP F8 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 280.92 1160.84 1.00 General
AIRLOOP F9 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.41 476.07 1160.84 1.00 General
AIRLOOP F9 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.40 466.24 1160.84 1.00 General
AIRLOOP F9 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.36 421.08 1160.84 1.00 General
AIRLOOP F9 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.34 396.36 1160.84 1.00 General
AIRLOOP F9 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 269.42 1160.84 1.00 General
AIRLOOP F9 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 268.55 1160.84 1.00 General
AIRLOOP F9 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 291.96 1160.84 1.00 General
AIRLOOP F9 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 292.60 1160.84 1.00 General
AIRLOOP T SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.50 578.50 1160.84 1.00 General
AIRLOOP T NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.48 561.28 1160.84 1.00 General
AIRLOOP T SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.45 518.60 1160.84 1.00 General
AIRLOOP T NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.41 477.45 1160.84 1.00 General
AIRLOOP T N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 352.50 1160.84 1.00 General
AIRLOOP T N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 352.35 1160.84 1.00 General
AIRLOOP T S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.34 394.79 1160.84 1.00 General
AIRLOOP T S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.34 395.40 1160.84 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
SHWSYS1 PUMP Pump:ConstantSpeed Intermittent 29891.00 0.0003 36.93 127739.32 0.30
PLANT CIRC PUMP Pump:ConstantSpeed Intermittent 224180.02 0.0079 2527.04 319344.75 0.90


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
SHWSYS1 WATER HEATER WaterHeater:Mixed 2.27 175842.64 0.80 0.00 0.00



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:36

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 3375.32 4050.38 0.275 0.330 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 42.44 0.00720
G NW APARTMENT 3300.19 3960.22 0.269 0.323 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 41.12 0.00720
OFFICE 4432.39 5318.87 0.361 0.433 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 11:15:00 40.94 0.00720
G NE APARTMENT 2764.49 3317.38 0.225 0.270 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 39.74 0.00720
G N1 APARTMENT 1820.87 2185.04 0.148 0.178 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 39.62 0.00720
G N2 APARTMENT 1809.93 2171.92 0.148 0.177 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 39.62 0.00720
G S1 APARTMENT 2009.29 2411.15 0.164 0.197 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 43.25 0.00720
G S2 APARTMENT 2070.50 2484.60 0.169 0.203 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 43.25 0.00720
F2 SW APARTMENT 3903.69 4684.43 0.318 0.382 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 42.20 0.00720
F2 NW APARTMENT 3814.50 4577.40 0.311 0.373 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 41.12 0.00720
F2 SE APARTMENT 3685.45 4422.53 0.300 0.360 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 11:30:00 41.24 0.00720
F2 NE APARTMENT 3232.57 3879.09 0.263 0.316 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 10:45:00 40.19 0.00720
F2 N1 APARTMENT 2108.16 2529.79 0.172 0.206 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 40.07 0.00720
F2 N2 APARTMENT 2099.65 2519.58 0.171 0.205 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 40.07 0.00720
F2 S1 APARTMENT 2345.60 2814.71 0.191 0.229 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 43.25 0.00720
F2 S2 APARTMENT 2365.20 2838.24 0.193 0.231 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 43.25 0.00720
F3 SW APARTMENT 3927.89 4713.47 0.320 0.384 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 42.20 0.00720
F3 NW APARTMENT 3840.74 4608.88 0.313 0.376 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 41.12 0.00720
F3 SE APARTMENT 3511.26 4213.51 0.286 0.343 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 11:30:00 41.24 0.00720
F3 NE APARTMENT 3273.62 3928.35 0.267 0.320 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 10:45:00 40.19 0.00720
F3 N1 APARTMENT 2136.42 2563.71 0.174 0.209 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 40.07 0.00720
F3 N2 APARTMENT 2128.10 2553.72 0.173 0.208 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 40.07 0.00720
F3 S1 APARTMENT 2372.83 2847.39 0.193 0.232 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 43.25 0.00720
F3 S2 APARTMENT 2380.63 2856.76 0.194 0.233 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 43.25 0.00720
F4 SW APARTMENT 3965.43 4758.52 0.323 0.388 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 42.20 0.00720
F4 NW APARTMENT 3877.61 4653.14 0.316 0.379 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 41.12 0.00720
F4 SE APARTMENT 3528.16 4233.79 0.288 0.345 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 11:30:00 41.24 0.00720
F4 NE APARTMENT 3310.83 3973.00 0.270 0.324 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 10:45:00 40.19 0.00720
F4 N1 APARTMENT 2169.35 2603.22 0.177 0.212 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 40.07 0.00720
F4 N2 APARTMENT 2161.15 2593.38 0.176 0.211 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 40.07 0.00720
F4 S1 APARTMENT 2402.12 2882.54 0.196 0.235 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 43.25 0.00720
F4 S2 APARTMENT 2408.21 2889.85 0.196 0.236 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 43.25 0.00720
M SW APARTMENT 4021.02 4825.22 0.328 0.393 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 42.44 0.00720
M NW APARTMENT 3932.96 4719.55 0.321 0.385 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 41.42 0.00720
M SE APARTMENT 3580.91 4297.10 0.292 0.350 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 11:30:00 41.24 0.00720
M NE APARTMENT 3366.11 4039.33 0.274 0.329 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 10:45:00 40.19 0.00720
M N1 APARTMENT 2220.05 2664.06 0.181 0.217 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 40.07 0.00720
M N2 APARTMENT 2211.94 2654.33 0.180 0.216 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 40.07 0.00720
M S1 APARTMENT 2449.53 2939.44 0.200 0.240 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 43.25 0.00720
M S2 APARTMENT 2455.36 2946.43 0.200 0.240 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 43.25 0.00720
F6 SW APARTMENT 4015.25 4818.30 0.327 0.393 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 42.44 0.00720
F6 NW APARTMENT 3925.97 4711.17 0.320 0.384 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 41.42 0.00720
F6 SE APARTMENT 3574.80 4289.75 0.291 0.350 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 11:30:00 41.24 0.00720
F6 NE APARTMENT 3359.36 4031.24 0.274 0.329 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 10:45:00 40.19 0.00720
F6 N1 APARTMENT 2210.57 2652.68 0.180 0.216 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 40.07 0.00720
F6 N2 APARTMENT 2202.58 2643.09 0.180 0.215 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 40.07 0.00720
F6 S1 APARTMENT 2438.60 2926.32 0.199 0.238 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 43.40 0.00720
F6 S2 APARTMENT 2444.16 2932.99 0.199 0.239 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 43.25 0.00720
F7 SW APARTMENT 4028.41 4834.09 0.328 0.394 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 42.44 0.00720
F7 NW APARTMENT 3938.84 4726.61 0.321 0.385 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 41.42 0.00720
F7 SE APARTMENT 3587.76 4305.31 0.292 0.351 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 11:30:00 41.24 0.00720
F7 NE APARTMENT 3373.31 4047.97 0.275 0.330 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 11:00:00 40.64 0.00720
F7 N1 APARTMENT 2220.66 2664.79 0.181 0.217 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 40.52 0.00720
F7 N2 APARTMENT 2212.96 2655.55 0.180 0.216 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 40.52 0.00720
F7 S1 APARTMENT 2446.84 2936.21 0.199 0.239 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 43.40 0.00720
F7 S2 APARTMENT 2452.07 2942.48 0.200 0.240 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 43.25 0.00720
F8 SW APARTMENT 4055.94 4867.13 0.331 0.397 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 42.44 0.00720
F8 NW APARTMENT 3966.31 4759.57 0.323 0.388 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 41.42 0.00720
F8 SE APARTMENT 3614.68 4337.62 0.295 0.354 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 11:30:00 41.24 0.00720
F8 NE APARTMENT 3400.97 4081.16 0.277 0.333 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 11:00:00 40.64 0.00720
F8 N1 APARTMENT 2245.59 2694.70 0.183 0.220 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 40.52 0.00720
F8 N2 APARTMENT 2237.98 2685.57 0.182 0.219 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 40.52 0.00720
F8 S1 APARTMENT 2469.39 2963.26 0.201 0.242 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 43.40 0.00720
F8 S2 APARTMENT 2474.39 2969.27 0.202 0.242 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 43.40 0.00720
F9 SW APARTMENT 4193.36 5032.03 0.342 0.410 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 42.20 0.00720
F9 NW APARTMENT 4106.72 4928.06 0.335 0.402 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 41.42 0.00720
F9 SE APARTMENT 3708.93 4450.72 0.302 0.363 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 11:45:00 41.54 0.00720
F9 NE APARTMENT 3491.22 4189.46 0.285 0.341 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 11:00:00 40.64 0.00720
F9 N1 APARTMENT 2373.05 2847.66 0.193 0.232 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 40.07 0.00720
F9 N2 APARTMENT 2365.37 2838.44 0.193 0.231 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 40.52 0.00720
F9 S1 APARTMENT 2571.65 3085.98 0.210 0.252 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 43.40 0.00720
F9 S2 APARTMENT 2577.22 3092.67 0.210 0.252 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 43.40 0.00720
T SW APARTMENT 5095.57 6114.69 0.415 0.498 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 15:45:00 42.86 0.00720
T NW APARTMENT 4943.93 5932.71 0.403 0.484 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 42.44 0.00720
T SE APARTMENT 4567.98 5481.57 0.372 0.447 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 43.40 0.00720
T NE APARTMENT 4205.49 5046.58 0.343 0.411 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 11:15:00 40.94 0.00720
T N1 APARTMENT 3104.89 3725.87 0.253 0.304 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 43.40 0.00720
T N2 APARTMENT 3103.56 3724.27 0.253 0.304 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 14:45:00 43.40 0.00720
T S1 APARTMENT 3477.37 4172.84 0.283 0.340 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 43.40 0.00720
T S2 APARTMENT 3482.75 4179.30 0.284 0.341 PHOENIX SKY HARBOR INTL AP ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 43.40 0.00720


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1075.54 1290.65 0.050 0.060 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 09:00:00 3.70 0.00513
G NW APARTMENT 1076.65 1291.98 0.050 0.060 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 09:15:00 3.70 0.00513
OFFICE 1334.90 1601.88 0.062 0.074 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 19:00:00 3.70 0.00513
G NE APARTMENT 1072.79 1287.35 0.050 0.060 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 09:15:00 3.70 0.00513
G N1 APARTMENT 625.66 750.79 0.029 0.035 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 09:15:00 3.70 0.00513
G N2 APARTMENT 625.60 750.72 0.029 0.035 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 09:15:00 3.70 0.00513
G S1 APARTMENT 622.41 746.90 0.029 0.035 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 09:15:00 3.70 0.00513
G S2 APARTMENT 627.60 753.12 0.029 0.035 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 09:15:00 3.70 0.00513
F2 SW APARTMENT 1037.27 1244.72 0.048 0.058 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F2 NW APARTMENT 1038.01 1245.61 0.048 0.058 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F2 SE APARTMENT 1049.40 1259.28 0.049 0.058 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F2 NE APARTMENT 1033.64 1240.37 0.048 0.057 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F2 N1 APARTMENT 504.98 605.98 0.023 0.028 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F2 N2 APARTMENT 504.91 605.89 0.023 0.028 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F2 S1 APARTMENT 506.55 607.86 0.023 0.028 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F2 S2 APARTMENT 507.68 609.21 0.024 0.028 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F3 SW APARTMENT 1023.56 1228.27 0.047 0.057 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F3 NW APARTMENT 1024.11 1228.93 0.047 0.057 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F3 SE APARTMENT 1021.47 1225.76 0.047 0.057 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F3 NE APARTMENT 1019.96 1223.95 0.047 0.057 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F3 N1 APARTMENT 475.99 571.19 0.022 0.026 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F3 N2 APARTMENT 475.92 571.10 0.022 0.026 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F3 S1 APARTMENT 475.94 571.12 0.022 0.026 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F3 S2 APARTMENT 476.08 571.29 0.022 0.026 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F4 SW APARTMENT 1036.46 1243.76 0.048 0.058 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F4 NW APARTMENT 1037.26 1244.71 0.048 0.058 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F4 SE APARTMENT 1032.86 1239.43 0.048 0.057 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F4 NE APARTMENT 1033.41 1240.10 0.048 0.057 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F4 N1 APARTMENT 476.91 572.29 0.022 0.027 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F4 N2 APARTMENT 476.84 572.21 0.022 0.027 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F4 S1 APARTMENT 476.37 571.65 0.022 0.026 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F4 S2 APARTMENT 476.34 571.61 0.022 0.026 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
M SW APARTMENT 1036.17 1243.40 0.048 0.058 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
M NW APARTMENT 1036.25 1243.50 0.048 0.058 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
M SE APARTMENT 1032.67 1239.20 0.048 0.057 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
M NE APARTMENT 1032.72 1239.27 0.048 0.057 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
M N1 APARTMENT 468.68 562.42 0.022 0.026 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
M N2 APARTMENT 468.62 562.34 0.022 0.026 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
M S1 APARTMENT 468.80 562.56 0.022 0.026 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
M S2 APARTMENT 468.74 562.49 0.022 0.026 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F6 SW APARTMENT 1084.50 1301.40 0.050 0.060 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F6 NW APARTMENT 1085.28 1302.34 0.050 0.060 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F6 SE APARTMENT 1081.27 1297.52 0.050 0.060 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F6 NE APARTMENT 1082.05 1298.46 0.050 0.060 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F6 N1 APARTMENT 506.24 607.49 0.023 0.028 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F6 N2 APARTMENT 506.18 607.42 0.023 0.028 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F6 S1 APARTMENT 505.64 606.77 0.023 0.028 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F6 S2 APARTMENT 505.59 606.70 0.023 0.028 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F7 SW APARTMENT 1114.89 1337.86 0.052 0.062 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F7 NW APARTMENT 1115.49 1338.59 0.052 0.062 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F7 SE APARTMENT 1111.95 1334.35 0.052 0.062 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F7 NE APARTMENT 1112.56 1335.07 0.052 0.062 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F7 N1 APARTMENT 528.88 634.66 0.024 0.029 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F7 N2 APARTMENT 528.83 634.59 0.024 0.029 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F7 S1 APARTMENT 528.43 634.12 0.024 0.029 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F7 S2 APARTMENT 528.38 634.06 0.024 0.029 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F8 SW APARTMENT 1147.67 1377.20 0.053 0.064 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F8 NW APARTMENT 1147.99 1377.58 0.053 0.064 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F8 SE APARTMENT 1145.02 1374.03 0.053 0.064 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F8 NE APARTMENT 1145.34 1374.41 0.053 0.064 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F8 N1 APARTMENT 554.95 665.94 0.026 0.031 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F8 N2 APARTMENT 554.90 665.89 0.026 0.031 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F8 S1 APARTMENT 554.77 665.72 0.026 0.031 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F8 S2 APARTMENT 554.72 665.67 0.026 0.031 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F9 SW APARTMENT 1251.06 1501.27 0.058 0.070 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F9 NW APARTMENT 1249.90 1499.88 0.058 0.069 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F9 SE APARTMENT 1248.68 1498.41 0.058 0.069 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F9 NE APARTMENT 1247.52 1497.02 0.058 0.069 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F9 N1 APARTMENT 646.01 775.21 0.030 0.036 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F9 N2 APARTMENT 645.97 775.16 0.030 0.036 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F9 S1 APARTMENT 647.09 776.51 0.030 0.036 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
F9 S2 APARTMENT 647.05 776.46 0.030 0.036 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
T SW APARTMENT 1605.13 1926.16 0.074 0.089 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
T NW APARTMENT 1607.20 1928.64 0.074 0.089 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
T SE APARTMENT 1603.12 1923.74 0.074 0.089 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
T NE APARTMENT 1605.19 1926.23 0.074 0.089 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
T N1 APARTMENT 1027.22 1232.67 0.048 0.057 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
T N2 APARTMENT 1027.19 1232.62 0.048 0.057 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
T S1 APARTMENT 1024.35 1229.22 0.047 0.057 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513
T S2 APARTMENT 1024.31 1229.18 0.047 0.057 PHOENIX SKY HARBOR INTL AP ANN HTG 99.6% CONDNS DB 12/21 15:00:00 3.70 0.00513


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
AIRLOOP G SW 0.33 0.33 0.06 0.06
AIRLOOP G NW 0.32 0.32 0.06 0.06
AIRLOOP OFFICE 0.43 0.43 0.07 0.07
AIRLOOP G NE 0.27 0.27 0.06 0.06
AIRLOOP G N1 0.18 0.18 0.03 0.03
AIRLOOP G N2 0.18 0.18 0.03 0.03
AIRLOOP G S1 0.20 0.20 0.03 0.03
AIRLOOP G S2 0.20 0.20 0.03 0.03
AIRLOOP F2 SW 0.38 0.38 0.06 0.06
AIRLOOP F2 NW 0.37 0.37 0.06 0.06
AIRLOOP F2 SE 0.36 0.36 0.06 0.06
AIRLOOP F2 NE 0.32 0.32 0.06 0.06
AIRLOOP F2 N1 0.21 0.21 0.03 0.03
AIRLOOP F2 N2 0.21 0.21 0.03 0.03
AIRLOOP F2 S1 0.23 0.23 0.03 0.03
AIRLOOP F2 S2 0.23 0.23 0.03 0.03
AIRLOOP F3 SW 0.38 0.38 0.06 0.06
AIRLOOP F3 NW 0.38 0.38 0.06 0.06
AIRLOOP F3 SE 0.34 0.34 0.06 0.06
AIRLOOP F3 NE 0.32 0.32 0.06 0.06
AIRLOOP F3 N1 0.21 0.21 0.03 0.03
AIRLOOP F3 N2 0.21 0.21 0.03 0.03
AIRLOOP F3 S1 0.23 0.23 0.03 0.03
AIRLOOP F3 S2 0.23 0.23 0.03 0.03
AIRLOOP F4 SW 0.39 0.39 0.06 0.06
AIRLOOP F4 NW 0.38 0.38 0.06 0.06
AIRLOOP F4 SE 0.35 0.35 0.06 0.06
AIRLOOP F4 NE 0.32 0.32 0.06 0.06
AIRLOOP F4 N1 0.21 0.21 0.03 0.03
AIRLOOP F4 N2 0.21 0.21 0.03 0.03
AIRLOOP F4 S1 0.23 0.23 0.03 0.03
AIRLOOP F4 S2 0.24 0.24 0.03 0.03
AIRLOOP M SW 0.39 0.39 0.06 0.06
AIRLOOP M NW 0.38 0.38 0.06 0.06
AIRLOOP M SE 0.35 0.35 0.06 0.06
AIRLOOP M NE 0.33 0.33 0.06 0.06
AIRLOOP M N1 0.22 0.22 0.03 0.03
AIRLOOP M N2 0.22 0.22 0.03 0.03
AIRLOOP M S1 0.24 0.24 0.03 0.03
AIRLOOP M S2 0.24 0.24 0.03 0.03
AIRLOOP F6 SW 0.39 0.39 0.06 0.06
AIRLOOP F6 NW 0.38 0.38 0.06 0.06
AIRLOOP F6 SE 0.35 0.35 0.06 0.06
AIRLOOP F6 NE 0.33 0.33 0.06 0.06
AIRLOOP F6 N1 0.22 0.22 0.03 0.03
AIRLOOP F6 N2 0.22 0.22 0.03 0.03
AIRLOOP F6 S1 0.24 0.24 0.03 0.03
AIRLOOP F6 S2 0.24 0.24 0.03 0.03
AIRLOOP F7 SW 0.39 0.39 0.06 0.06
AIRLOOP F7 NW 0.39 0.39 0.06 0.06
AIRLOOP F7 SE 0.35 0.35 0.06 0.06
AIRLOOP F7 NE 0.33 0.33 0.06 0.06
AIRLOOP F7 N1 0.22 0.22 0.03 0.03
AIRLOOP F7 N2 0.22 0.22 0.03 0.03
AIRLOOP F7 S1 0.24 0.24 0.03 0.03
AIRLOOP F7 S2 0.24 0.24 0.03 0.03
AIRLOOP F8 SW 0.40 0.40 0.06 0.06
AIRLOOP F8 NW 0.39 0.39 0.06 0.06
AIRLOOP F8 SE 0.35 0.35 0.06 0.06
AIRLOOP F8 NE 0.33 0.33 0.06 0.06
AIRLOOP F8 N1 0.22 0.22 0.03 0.03
AIRLOOP F8 N2 0.22 0.22 0.03 0.03
AIRLOOP F8 S1 0.24 0.24 0.03 0.03
AIRLOOP F8 S2 0.24 0.24 0.03 0.03
AIRLOOP F9 SW 0.41 0.41 0.07 0.07
AIRLOOP F9 NW 0.40 0.40 0.07 0.07
AIRLOOP F9 SE 0.36 0.36 0.07 0.07
AIRLOOP F9 NE 0.34 0.34 0.07 0.07
AIRLOOP F9 N1 0.23 0.23 0.04 0.04
AIRLOOP F9 N2 0.23 0.23 0.04 0.04
AIRLOOP F9 S1 0.25 0.25 0.04 0.04
AIRLOOP F9 S2 0.25 0.25 0.04 0.04
AIRLOOP T SW 0.50 0.50 0.09 0.09
AIRLOOP T NW 0.48 0.48 0.09 0.09
AIRLOOP T SE 0.45 0.45 0.09 0.09
AIRLOOP T NE 0.41 0.41 0.09 0.09
AIRLOOP T N1 0.30 0.30 0.06 0.06
AIRLOOP T N2 0.30 0.30 0.06 0.06
AIRLOOP T S1 0.34 0.34 0.06 0.06
AIRLOOP T S2 0.34 0.34 0.06 0.06



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:36

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 3738.50 3191.25 107.75
G NW APARTMENT 3329.75 4230.25 110.75
OFFICE 1475.00 180.50 0.00
G NE APARTMENT 3348.00 4167.00 116.75
G N1 APARTMENT 3088.00 4622.50 136.75
G N2 APARTMENT 3090.25 4620.75 136.25
G S1 APARTMENT 3388.25 3389.25 122.75
G S2 APARTMENT 3421.25 3299.75 120.00
F2 SW APARTMENT 4698.25 1607.50 55.75
F2 NW APARTMENT 3961.25 3071.75 66.00
F2 SE APARTMENT 4999.75 1402.25 52.00
F2 NE APARTMENT 3975.25 2993.50 71.50
F2 N1 APARTMENT 3617.00 3293.25 85.75
F2 N2 APARTMENT 3617.50 3289.50 85.75
F2 S1 APARTMENT 4389.25 1432.75 66.25
F2 S2 APARTMENT 4409.25 1402.00 66.00
F3 SW APARTMENT 4874.50 1342.75 57.75
F3 NW APARTMENT 4078.00 2819.75 66.50
F3 SE APARTMENT 4978.25 1352.75 59.00
F3 NE APARTMENT 4094.25 2770.75 69.00
F3 N1 APARTMENT 3748.00 2982.00 79.75
F3 N2 APARTMENT 3747.75 2977.00 79.75
F3 S1 APARTMENT 4640.75 1049.75 67.50
F3 S2 APARTMENT 4643.25 1048.00 67.25
F4 SW APARTMENT 4894.25 1280.00 60.25
F4 NW APARTMENT 4086.75 2754.50 69.25
F4 SE APARTMENT 4963.50 1329.75 62.75
F4 NE APARTMENT 4105.75 2702.00 71.50
F4 N1 APARTMENT 3768.50 2857.75 80.00
F4 N2 APARTMENT 3767.50 2859.50 80.50
F4 S1 APARTMENT 4675.75 952.50 68.50
F4 S2 APARTMENT 4677.50 955.50 69.00
M SW APARTMENT 4908.50 1268.25 60.00
M NW APARTMENT 4103.50 2714.00 70.25
M SE APARTMENT 4973.75 1329.00 65.00
M NE APARTMENT 4133.25 2673.75 71.75
M N1 APARTMENT 3797.00 2803.00 79.25
M N2 APARTMENT 3796.00 2803.50 79.75
M S1 APARTMENT 4703.50 924.25 68.25
M S2 APARTMENT 4704.25 931.25 68.25
F6 SW APARTMENT 4773.25 1400.25 68.25
F6 NW APARTMENT 4012.25 2830.75 76.50
F6 SE APARTMENT 4833.75 1442.00 70.00
F6 NE APARTMENT 4031.75 2777.50 79.50
F6 N1 APARTMENT 3711.25 2925.25 87.50
F6 N2 APARTMENT 3712.50 2930.00 87.25
F6 S1 APARTMENT 4564.25 1054.50 74.25
F6 S2 APARTMENT 4566.00 1057.75 74.50
F7 SW APARTMENT 4696.50 1483.75 72.75
F7 NW APARTMENT 3957.25 2886.50 79.75
F7 SE APARTMENT 4751.25 1518.50 73.25
F7 NE APARTMENT 3978.50 2840.00 84.00
F7 N1 APARTMENT 3665.50 2999.25 91.00
F7 N2 APARTMENT 3665.75 2996.50 91.25
F7 S1 APARTMENT 4488.75 1142.25 78.50
F7 S2 APARTMENT 4492.25 1145.50 78.75
F8 SW APARTMENT 4656.50 1557.50 74.25
F8 NW APARTMENT 3933.00 2932.75 81.00
F8 SE APARTMENT 4704.75 1599.00 75.75
F8 NE APARTMENT 3956.25 2879.75 85.75
F8 N1 APARTMENT 3647.50 3051.25 92.25
F8 N2 APARTMENT 3651.00 3051.75 92.25
F8 S1 APARTMENT 4437.00 1218.25 79.50
F8 S2 APARTMENT 4437.50 1222.75 79.50
F9 SW APARTMENT 4648.00 1664.50 73.75
F9 NW APARTMENT 3973.00 2990.00 80.00
F9 SE APARTMENT 4692.00 1695.00 74.00
F9 NE APARTMENT 3992.00 2932.00 84.50
F9 N1 APARTMENT 3699.50 3091.75 89.00
F9 N2 APARTMENT 3701.50 3087.75 88.50
F9 S1 APARTMENT 4434.25 1357.50 76.00
F9 S2 APARTMENT 4434.75 1364.50 76.50
T SW APARTMENT 4970.50 2330.25 87.75
T NW APARTMENT 4252.75 3135.25 107.00
T SE APARTMENT 5063.75 2277.50 88.00
T NE APARTMENT 4350.25 3069.50 120.75
T N1 APARTMENT 4072.00 3216.50 95.75
T N2 APARTMENT 4074.75 3213.50 95.75
T S1 APARTMENT 4904.75 2112.00 93.00
T S2 APARTMENT 4910.00 2117.00 93.00
G CORRIDOR 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00
Facility 5741.00 4645.50 175.25
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 0.00 69.50 0.00 69.50
G NW APARTMENT 0.00 57.75 0.00 57.75
OFFICE 0.25 10.50 0.00 8.00
G NE APARTMENT 0.00 16.25 0.00 16.25
G N1 APARTMENT 0.75 49.75 0.75 49.75
G N2 APARTMENT 2.00 49.00 2.00 49.00
G S1 APARTMENT 1.00 120.25 1.00 120.25
G S2 APARTMENT 2.00 98.75 2.00 98.75
F2 SW APARTMENT 0.00 59.75 0.00 59.75
F2 NW APARTMENT 0.00 37.00 0.00 37.00
F2 SE APARTMENT 0.00 8.00 0.00 8.00
F2 NE APARTMENT 0.00 13.00 0.00 13.00
F2 N1 APARTMENT 0.50 45.50 0.50 45.50
F2 N2 APARTMENT 1.00 45.00 1.00 45.00
F2 S1 APARTMENT 0.00 151.50 0.00 151.50
F2 S2 APARTMENT 0.00 143.50 0.00 143.50
F3 SW APARTMENT 0.00 61.50 0.00 61.50
F3 NW APARTMENT 0.00 42.25 0.00 42.25
F3 SE APARTMENT 0.00 28.25 0.00 28.25
F3 NE APARTMENT 0.00 15.50 0.00 15.50
F3 N1 APARTMENT 0.50 52.75 0.50 52.75
F3 N2 APARTMENT 1.00 53.75 1.00 53.75
F3 S1 APARTMENT 0.00 177.25 0.00 177.25
F3 S2 APARTMENT 0.00 173.25 0.00 173.25
F4 SW APARTMENT 0.00 59.75 0.00 59.75
F4 NW APARTMENT 0.00 46.25 0.00 46.25
F4 SE APARTMENT 0.00 28.50 0.00 28.50
F4 NE APARTMENT 0.00 18.75 0.00 18.75
F4 N1 APARTMENT 0.25 57.00 0.25 57.00
F4 N2 APARTMENT 0.50 56.75 0.50 56.75
F4 S1 APARTMENT 0.00 168.75 0.00 168.75
F4 S2 APARTMENT 0.00 165.00 0.00 165.00
M SW APARTMENT 0.00 56.25 0.00 56.25
M NW APARTMENT 0.00 46.50 0.00 46.50
M SE APARTMENT 0.00 27.00 0.00 27.00
M NE APARTMENT 0.00 19.50 0.00 19.50
M N1 APARTMENT 0.75 58.25 0.75 58.25
M N2 APARTMENT 0.50 57.50 0.50 57.50
M S1 APARTMENT 0.00 151.50 0.00 151.50
M S2 APARTMENT 0.00 148.25 0.00 148.25
F6 SW APARTMENT 0.00 56.50 0.00 56.50
F6 NW APARTMENT 0.00 49.00 0.00 49.00
F6 SE APARTMENT 0.00 26.75 0.00 26.75
F6 NE APARTMENT 0.00 20.25 0.00 20.25
F6 N1 APARTMENT 0.75 60.25 0.75 60.25
F6 N2 APARTMENT 0.50 61.00 0.50 61.00
F6 S1 APARTMENT 0.00 137.50 0.00 137.50
F6 S2 APARTMENT 0.00 136.75 0.00 136.75
F7 SW APARTMENT 0.00 56.50 0.00 56.50
F7 NW APARTMENT 0.00 50.75 0.00 50.75
F7 SE APARTMENT 0.00 24.50 0.00 24.50
F7 NE APARTMENT 0.00 21.25 0.00 21.25
F7 N1 APARTMENT 0.25 59.75 0.25 59.75
F7 N2 APARTMENT 0.25 60.75 0.25 60.75
F7 S1 APARTMENT 0.00 126.25 0.00 126.25
F7 S2 APARTMENT 0.00 126.50 0.00 126.50
F8 SW APARTMENT 0.00 56.00 0.00 56.00
F8 NW APARTMENT 0.00 51.25 0.00 51.25
F8 SE APARTMENT 0.00 24.75 0.00 24.75
F8 NE APARTMENT 0.00 23.00 0.00 23.00
F8 N1 APARTMENT 0.50 61.00 0.50 61.00
F8 N2 APARTMENT 0.25 61.25 0.25 61.25
F8 S1 APARTMENT 0.00 118.25 0.00 118.25
F8 S2 APARTMENT 0.00 117.25 0.00 117.25
F9 SW APARTMENT 0.00 51.50 0.00 51.50
F9 NW APARTMENT 0.00 48.75 0.00 48.75
F9 SE APARTMENT 0.00 21.50 0.00 21.50
F9 NE APARTMENT 0.00 25.00 0.00 25.00
F9 N1 APARTMENT 0.00 57.75 0.00 57.75
F9 N2 APARTMENT 0.00 54.50 0.00 54.50
F9 S1 APARTMENT 0.00 95.50 0.00 95.50
F9 S2 APARTMENT 0.00 94.50 0.00 94.50
T SW APARTMENT 0.00 31.75 0.00 31.75
T NW APARTMENT 0.00 40.25 0.00 40.25
T SE APARTMENT 0.00 5.75 0.00 5.75
T NE APARTMENT 0.00 16.25 0.00 16.25
T N1 APARTMENT 0.00 19.00 0.00 19.00
T N2 APARTMENT 0.00 16.00 0.00 16.00
T S1 APARTMENT 0.00 49.00 0.00 49.00
T S2 APARTMENT 0.00 48.75 0.00 48.75
G CORRIDOR 0.00 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
Facility 11.50 364.75 11.25 362.25
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:36

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.356 0.119 0.000 0.296
G NW APARTMENT 1.71 2.50 268.96 0.356 0.119 0.000 0.279
OFFICE 0.94 1.00 268.96 0.522 0.135 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.356 0.119 0.000 0.279
G N1 APARTMENT 1.71 2.50 268.96 0.356 0.072 0.000 0.268
G N2 APARTMENT 1.71 2.50 268.97 0.356 0.072 0.000 0.268
G S1 APARTMENT 1.71 2.50 268.96 0.356 0.072 0.000 0.293
G S2 APARTMENT 1.71 2.50 268.97 0.356 0.072 0.000 0.294
F2 SW APARTMENT 1.71 2.50 268.96 0.356 0.171 0.000 0.329
F2 NW APARTMENT 1.71 2.50 268.96 0.356 0.171 0.000 0.315
F2 SE APARTMENT 1.71 2.50 268.96 0.356 0.171 0.000 0.330
F2 NE APARTMENT 1.71 2.50 268.96 0.356 0.171 0.000 0.314
F2 N1 APARTMENT 1.71 2.50 268.96 0.356 0.103 0.000 0.307
F2 N2 APARTMENT 1.71 2.50 268.97 0.356 0.103 0.000 0.307
F2 S1 APARTMENT 1.71 2.50 268.96 0.356 0.103 0.000 0.328
F2 S2 APARTMENT 1.71 2.50 268.97 0.356 0.103 0.000 0.328
F3 SW APARTMENT 1.71 2.50 268.96 0.356 0.203 0.000 0.353
F3 NW APARTMENT 1.71 2.50 268.96 0.356 0.203 0.000 0.339
F3 SE APARTMENT 1.71 2.50 268.96 0.356 0.203 0.000 0.353
F3 NE APARTMENT 1.71 2.50 268.96 0.356 0.203 0.000 0.339
F3 N1 APARTMENT 1.71 2.50 268.96 0.356 0.122 0.000 0.334
F3 N2 APARTMENT 1.71 2.50 268.97 0.356 0.122 0.000 0.334
F3 S1 APARTMENT 1.71 2.50 268.96 0.356 0.122 0.000 0.352
F3 S2 APARTMENT 1.71 2.50 268.97 0.356 0.122 0.000 0.352
F4 SW APARTMENT 1.71 2.50 268.96 0.356 0.227 0.000 0.356
F4 NW APARTMENT 1.71 2.50 268.96 0.356 0.226 0.000 0.344
F4 SE APARTMENT 1.71 2.50 268.96 0.356 0.227 0.000 0.357
F4 NE APARTMENT 1.71 2.50 268.96 0.356 0.226 0.000 0.343
F4 N1 APARTMENT 1.71 2.50 268.96 0.356 0.137 0.000 0.339
F4 N2 APARTMENT 1.71 2.50 268.97 0.356 0.137 0.000 0.339
F4 S1 APARTMENT 1.71 2.50 268.96 0.356 0.137 0.000 0.356
F4 S2 APARTMENT 1.71 2.50 268.97 0.356 0.137 0.000 0.356
M SW APARTMENT 1.71 2.50 268.96 0.356 0.246 0.000 0.369
M NW APARTMENT 1.71 2.50 268.96 0.356 0.246 0.000 0.356
M SE APARTMENT 1.71 2.50 268.96 0.356 0.246 0.000 0.369
M NE APARTMENT 1.71 2.50 268.96 0.356 0.246 0.000 0.355
M N1 APARTMENT 1.71 2.50 268.96 0.356 0.148 0.000 0.351
M N2 APARTMENT 1.71 2.50 268.97 0.356 0.148 0.000 0.351
M S1 APARTMENT 1.71 2.50 268.96 0.356 0.149 0.000 0.368
M S2 APARTMENT 1.71 2.50 268.97 0.356 0.149 0.000 0.368
F6 SW APARTMENT 1.71 2.50 268.96 0.356 0.263 0.000 0.379
F6 NW APARTMENT 1.71 2.50 268.96 0.356 0.263 0.000 0.365
F6 SE APARTMENT 1.71 2.50 268.96 0.356 0.263 0.000 0.380
F6 NE APARTMENT 1.71 2.50 268.96 0.356 0.263 0.000 0.365
F6 N1 APARTMENT 1.71 2.50 268.96 0.356 0.159 0.000 0.361
F6 N2 APARTMENT 1.71 2.50 268.97 0.356 0.159 0.000 0.361
F6 S1 APARTMENT 1.71 2.50 268.96 0.356 0.159 0.000 0.379
F6 S2 APARTMENT 1.71 2.50 268.97 0.356 0.159 0.000 0.379
F7 SW APARTMENT 1.71 2.50 268.96 0.356 0.278 0.000 0.388
F7 NW APARTMENT 1.71 2.50 268.96 0.356 0.278 0.000 0.373
F7 SE APARTMENT 1.71 2.50 268.96 0.356 0.278 0.000 0.388
F7 NE APARTMENT 1.71 2.50 268.96 0.356 0.278 0.000 0.373
F7 N1 APARTMENT 1.71 2.50 268.96 0.356 0.168 0.000 0.369
F7 N2 APARTMENT 1.71 2.50 268.97 0.356 0.168 0.000 0.369
F7 S1 APARTMENT 1.71 2.50 268.96 0.356 0.168 0.000 0.388
F7 S2 APARTMENT 1.71 2.50 268.97 0.356 0.168 0.000 0.388
F8 SW APARTMENT 1.71 2.50 268.96 0.356 0.291 0.000 0.398
F8 NW APARTMENT 1.71 2.50 268.96 0.356 0.291 0.000 0.382
F8 SE APARTMENT 1.71 2.50 268.96 0.356 0.291 0.000 0.398
F8 NE APARTMENT 1.71 2.50 268.96 0.356 0.291 0.000 0.382
F8 N1 APARTMENT 1.71 2.50 268.96 0.356 0.176 0.000 0.378
F8 N2 APARTMENT 1.71 2.50 268.97 0.356 0.176 0.000 0.378
F8 S1 APARTMENT 1.71 2.50 268.96 0.356 0.176 0.000 0.397
F8 S2 APARTMENT 1.71 2.50 268.97 0.356 0.176 0.000 0.397
F9 SW APARTMENT 1.71 2.50 268.96 0.356 0.304 0.000 0.407
F9 NW APARTMENT 1.71 2.50 268.96 0.356 0.304 0.000 0.391
F9 SE APARTMENT 1.71 2.50 268.96 0.356 0.304 0.000 0.407
F9 NE APARTMENT 1.71 2.50 268.96 0.356 0.304 0.000 0.390
F9 N1 APARTMENT 1.71 2.50 268.96 0.356 0.183 0.000 0.386
F9 N2 APARTMENT 1.71 2.50 268.97 0.356 0.183 0.000 0.386
F9 S1 APARTMENT 1.71 2.50 268.96 0.356 0.183 0.000 0.406
F9 S2 APARTMENT 1.71 2.50 268.97 0.356 0.183 0.000 0.406
T SW APARTMENT 1.71 2.50 268.96 0.356 0.315 0.000 0.412
T NW APARTMENT 1.71 2.50 268.96 0.355 0.315 0.000 0.398
T SE APARTMENT 1.71 2.50 268.96 0.356 0.315 0.000 0.412
T NE APARTMENT 1.71 2.50 268.96 0.355 0.315 0.000 0.398
T N1 APARTMENT 1.71 2.50 268.96 0.356 0.190 0.000 0.394
T N2 APARTMENT 1.71 2.50 268.97 0.356 0.190 0.000 0.394
T S1 APARTMENT 1.71 2.50 268.96 0.356 0.190 0.000 0.411
T S2 APARTMENT 1.71 2.50 268.97 0.356 0.190 0.000 0.411
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
OFFICE 0.94 1.00 268.96 0.507 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.345 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.96 0.346 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.346 0.000 0.000 0.000
F2 SW APARTMENT 1.71 2.50 268.96 0.346 0.000 0.000 0.000
F2 NW APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F2 SE APARTMENT 1.71 2.50 268.96 0.346 0.000 0.000 0.000
F2 NE APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F2 N1 APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F2 N2 APARTMENT 1.71 2.50 268.97 0.345 0.000 0.000 0.000
F2 S1 APARTMENT 1.71 2.50 268.96 0.347 0.000 0.000 0.000
F2 S2 APARTMENT 1.71 2.50 268.97 0.347 0.000 0.000 0.000
F3 SW APARTMENT 1.71 2.50 268.96 0.346 0.000 0.000 0.000
F3 NW APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F3 SE APARTMENT 1.71 2.50 268.96 0.346 0.000 0.000 0.000
F3 NE APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F3 N1 APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F3 N2 APARTMENT 1.71 2.50 268.97 0.345 0.000 0.000 0.000
F3 S1 APARTMENT 1.71 2.50 268.96 0.347 0.000 0.000 0.000
F3 S2 APARTMENT 1.71 2.50 268.97 0.347 0.000 0.000 0.000
F4 SW APARTMENT 1.71 2.50 268.96 0.346 0.000 0.000 0.000
F4 NW APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F4 SE APARTMENT 1.71 2.50 268.96 0.346 0.000 0.000 0.000
F4 NE APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F4 N1 APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F4 N2 APARTMENT 1.71 2.50 268.97 0.345 0.000 0.000 0.000
F4 S1 APARTMENT 1.71 2.50 268.96 0.347 0.000 0.000 0.000
F4 S2 APARTMENT 1.71 2.50 268.97 0.347 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.96 0.346 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.96 0.346 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 0.345 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.96 0.347 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 0.347 0.000 0.000 0.000
F6 SW APARTMENT 1.71 2.50 268.96 0.346 0.000 0.000 0.000
F6 NW APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F6 SE APARTMENT 1.71 2.50 268.96 0.346 0.000 0.000 0.000
F6 NE APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F6 N1 APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F6 N2 APARTMENT 1.71 2.50 268.97 0.345 0.000 0.000 0.000
F6 S1 APARTMENT 1.71 2.50 268.96 0.347 0.000 0.000 0.000
F6 S2 APARTMENT 1.71 2.50 268.97 0.347 0.000 0.000 0.000
F7 SW APARTMENT 1.71 2.50 268.96 0.346 0.000 0.000 0.000
F7 NW APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F7 SE APARTMENT 1.71 2.50 268.96 0.346 0.000 0.000 0.000
F7 NE APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F7 N1 APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F7 N2 APARTMENT 1.71 2.50 268.97 0.345 0.000 0.000 0.000
F7 S1 APARTMENT 1.71 2.50 268.96 0.347 0.000 0.000 0.000
F7 S2 APARTMENT 1.71 2.50 268.97 0.347 0.000 0.000 0.000
F8 SW APARTMENT 1.71 2.50 268.96 0.346 0.000 0.000 0.000
F8 NW APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F8 SE APARTMENT 1.71 2.50 268.96 0.346 0.000 0.000 0.000
F8 NE APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F8 N1 APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F8 N2 APARTMENT 1.71 2.50 268.97 0.345 0.000 0.000 0.000
F8 S1 APARTMENT 1.71 2.50 268.96 0.347 0.000 0.000 0.000
F8 S2 APARTMENT 1.71 2.50 268.97 0.347 0.000 0.000 0.000
F9 SW APARTMENT 1.71 2.50 268.96 0.346 0.000 0.000 0.000
F9 NW APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F9 SE APARTMENT 1.71 2.50 268.96 0.346 0.000 0.000 0.000
F9 NE APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F9 N1 APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F9 N2 APARTMENT 1.71 2.50 268.97 0.345 0.000 0.000 0.000
F9 S1 APARTMENT 1.71 2.50 268.96 0.346 0.000 0.000 0.000
F9 S2 APARTMENT 1.71 2.50 268.97 0.346 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.345 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.345 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:36

Surfaces by Class

Total Outdoors
Wall 420 140
Floor 90 9
Roof 90 9
Internal Mass 80 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 140 140
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 80
Conditioned Zones 80
Unconditioned Zones 10
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 4156
Defaulted Fields 814
Fields with Defaults 11184
Autosized Fields 1293
Autosizable Fields 1630
Autocalculated Fields 907
Autocalculatable Fields 1710



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2015-09-09 19:11:36

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 3734.52 64869.50 11-JAN-03:15 197190.81 07-JUL-18:00
Electricity:Building 1433.88 25760.85 01-JAN-03:15 70162.48 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity 296.56 6715.87 01-JAN-00:15 14401.37 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 242.55 5824.91 01-JAN-00:15 11484.27 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:OFFICE 39.38 663.42 01-JAN-00:15 2934.49 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 29.88 469.18 01-JAN-00:15 2345.88 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:G CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F2 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F2 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F3 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F3 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F4 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F4 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:M SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M CORRIDOR 32.88 1042.61 01-JAN-00:15 1042.61 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 32.88 1042.61 01-JAN-00:15 1042.61 01-JAN-00:15
Electricity:Zone:F6 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F6 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F7 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F7 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F8 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F8 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F9 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F9 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:T SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T CORRIDOR 179.47 1701.70 01-JAN-00:15 10868.20 01-JAN-07:15
InteriorLights:Electricity:Zone:T CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 54.01 890.97 01-JAN-00:15 2917.11 01-JAN-19:15
InteriorEquipment:Electricity 1137.32 19044.98 01-JAN-03:15 57142.09 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 1137.32 19044.98 01-JAN-03:15 57142.09 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 9.50 194.24 01-JAN-00:15 588.62 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T CORRIDOR 163.03 1180.40 01-JAN-00:15 10346.90 01-JAN-07:15
Fans:Electricity 884.47 28046.48 05-JAN-22:15 28046.48 01-JAN-00:15
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Electricity:HVAC 2014.19 28707.72 09-JAN-04:15 120887.63 10-AUG-16:15
ElectricityProduced:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityProduced:HVAC 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricityProduced 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 3734.52 64869.50 11-JAN-03:15 197190.81 07-JUL-18:00
ElectricityPurchased:Plant 3734.52 64869.50 11-JAN-03:15 197190.81 07-JUL-18:00
Cogeneration:ElectricityPurchased 3734.52 64869.50 11-JAN-03:15 197190.81 07-JUL-18:00
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 3734.52 64869.50 11-JAN-03:15 197190.81 07-JUL-18:00
ElectricityNet:Plant 3734.52 64869.50 11-JAN-03:15 197190.81 07-JUL-18:00
Cogeneration:ElectricityNet 3734.52 64869.50 11-JAN-03:15 197190.81 07-JUL-18:00
ExteriorLights:Electricity 162.75 0.00 01-JAN-07:45 10364.00 01-JAN-00:15
General:ExteriorLights:Electricity 162.75 0.00 01-JAN-07:45 10364.00 01-JAN-00:15
General:Fans:Electricity 884.47 28046.48 05-JAN-22:15 28046.48 01-JAN-00:15
Cooling:Electricity 1085.41 0.00 01-JAN-01:15 91024.32 10-AUG-16:00
Heating:Electricity 8.14 0.00 01-JAN-09:45 19770.67 07-MAR-03:00
Electricity:Plant 123.70 36.93 02-JAN-19:30 6383.99 01-AUG-17:45
HeatRejection:Electricity 44.12 0.00 01-JAN-06:00 3820.03 01-AUG-17:45
Boiler Parasitic:Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Pumps:Electricity 79.58 36.93 02-JAN-19:30 2563.97 01-JAN-00:15
WIRED_LTG_ELECTRICITY 0.44 0.00 01-JAN-00:15 21.60 01-JAN-19:30
WIRED_INT_EQUIP 979.40 1018.50 01-JAN-00:15 10185.00 01-JAN-07:15


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 863.21 2357.00 01-JAN-00:15 130830.56 10-FEB-07:15
Gas:Plant 863.21 2357.00 01-JAN-00:15 130830.56 10-FEB-07:15
WaterSystems:Gas 855.99 2357.00 01-JAN-00:15 74550.51 24-JAN-08:00
Water Heater:WaterSystems:Gas 855.99 2357.00 01-JAN-00:15 74550.51 24-JAN-08:00
Heating:Gas 7.22 0.00 01-JAN-00:15 62875.08 07-MAR-05:15
Boiler:Heating:Gas 7.22 0.00 01-JAN-00:15 62875.08 07-MAR-05:15


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
PlantLoopCoolingDemand:Facility 4572.14 0.00 01-JAN-01:15 433226.96 10-AUG-16:00
PlantLoopCoolingDemand:HVAC 4572.14 0.00 01-JAN-01:15 433226.96 10-AUG-16:00
CoolingCoils:PlantLoopCoolingDemand 4572.14 0.00 01-JAN-01:15 433226.96 10-AUG-16:00


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 8943.67 0.00 04-JAN-04:00 0.00 16-JUL-18:00
Water:Plant 8943.67 0.00 04-JAN-04:00 0.00 16-JUL-18:00
WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
MainsWater:Facility 8943.67 0.00 04-JAN-04:00 0.00 16-JUL-18:00
MainsWater:Plant 8943.67 0.00 04-JAN-04:00 0.00 16-JUL-18:00
WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
sub cat:WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
sub cat:WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
HeatRejection:Water 4165.15 0.00 01-JAN-06:00 0.00 16-JUL-18:00
HeatRejection:MainsWater 4165.15 0.00 01-JAN-06:00 0.00 16-JUL-18:00


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 682.22 299.55 27-JUL-01:15 94108.75 10-FEB-07:15
PlantLoopHeatingDemand:Plant 661.61 299.55 27-JUL-01:15 49191.84 25-JAN-08:00
WaterSystems:PlantLoopHeatingDemand 661.61 299.55 27-JUL-01:15 49191.84 25-JAN-08:00
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 6952.11 6624.99 16-FEB-02:15 611221.54 08-JUL-17:15
EnergyTransfer:Building 2699.45 4293.81 04-MAY-21:15 257371.11 09-JUL-17:00
EnergyTransfer:Zone:G SW APARTMENT 30.97 0.04 04-JAN-23:00 3877.54 29-SEP-14:30
Heating:EnergyTransfer 76.75 0.00 19-FEB-15:15 59879.32 07-MAR-03:00
Heating:EnergyTransfer:Zone:G SW APARTMENT 1.36 0.00 01-JAN-02:30 1026.24 07-MAR-03:00
Cooling:EnergyTransfer 2622.70 0.00 01-JAN-17:30 257371.11 09-JUL-17:00
Cooling:EnergyTransfer:Zone:G SW APARTMENT 29.61 0.00 01-JAN-00:15 3877.54 29-SEP-14:30
EnergyTransfer:Zone:G NW APARTMENT 25.01 0.11 23-MAY-04:45 3644.51 02-JUL-17:30
Heating:EnergyTransfer:Zone:G NW APARTMENT 2.41 0.00 07-JAN-16:15 1016.28 07-MAR-03:00
Cooling:EnergyTransfer:Zone:G NW APARTMENT 22.59 0.00 01-JAN-00:15 3644.51 02-JUL-17:30
EnergyTransfer:Zone:OFFICE 42.05 0.01 13-FEB-05:15 5008.99 29-SEP-10:30
Heating:EnergyTransfer:Zone:OFFICE 0.62 0.00 01-JAN-01:00 852.70 07-MAR-03:00
Cooling:EnergyTransfer:Zone:OFFICE 41.43 0.00 01-JAN-00:15 5008.99 29-SEP-10:30
EnergyTransfer:Zone:G NE APARTMENT 24.19 0.04 22-MAR-00:30 2860.52 16-JUL-17:45
Heating:EnergyTransfer:Zone:G NE APARTMENT 1.98 0.00 01-JAN-08:00 1024.14 07-MAR-03:00
Cooling:EnergyTransfer:Zone:G NE APARTMENT 22.21 0.00 01-JAN-00:15 2860.52 16-JUL-17:45
EnergyTransfer:Zone:G N1 APARTMENT 15.66 0.06 20-APR-23:15 1953.85 02-JUL-17:30
Heating:EnergyTransfer:Zone:G N1 APARTMENT 0.93 0.00 01-JAN-00:15 874.77 06-FEB-14:00
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 14.74 0.00 01-JAN-02:00 1953.85 02-JUL-17:30
EnergyTransfer:Zone:G N2 APARTMENT 15.67 0.02 22-APR-04:15 1941.89 02-JUL-17:30
Heating:EnergyTransfer:Zone:G N2 APARTMENT 0.92 0.00 01-JAN-00:15 874.29 06-FEB-14:00
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 14.74 0.00 01-JAN-02:00 1941.89 02-JUL-17:30
EnergyTransfer:Zone:G S1 APARTMENT 22.11 0.03 14-MAR-02:45 2401.95 01-OCT-11:45
Heating:EnergyTransfer:Zone:G S1 APARTMENT 0.27 0.00 01-JAN-00:15 467.80 07-MAR-03:00
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 21.85 0.00 01-JAN-11:30 2401.95 01-OCT-11:45
EnergyTransfer:Zone:G S2 APARTMENT 22.54 0.01 17-NOV-05:45 2461.93 01-OCT-12:00
Heating:EnergyTransfer:Zone:G S2 APARTMENT 0.27 0.00 01-JAN-00:15 451.84 07-MAR-03:00
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 22.27 0.00 01-JAN-11:30 2461.93 01-OCT-12:00
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F2 SW APARTMENT 42.26 0.02 04-MAY-23:15 4445.53 29-SEP-14:30
Heating:EnergyTransfer:Zone:F2 SW APARTMENT 0.74 0.00 01-JAN-03:15 933.66 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT 41.52 0.00 01-JAN-00:15 4445.53 29-SEP-14:30
EnergyTransfer:Zone:F2 NW APARTMENT 32.94 0.05 18-FEB-23:30 4168.11 02-JUL-17:30
Heating:EnergyTransfer:Zone:F2 NW APARTMENT 1.84 0.00 01-JAN-07:15 961.02 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT 31.10 0.00 01-JAN-00:15 4168.11 02-JUL-17:30
EnergyTransfer:Zone:F2 SE APARTMENT 44.20 0.01 28-DEC-01:30 4125.89 02-SEP-11:00
Heating:EnergyTransfer:Zone:F2 SE APARTMENT 0.52 0.00 01-JAN-02:15 873.58 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT 43.68 0.00 01-JAN-00:15 4125.89 02-SEP-11:00
EnergyTransfer:Zone:F2 NE APARTMENT 32.34 0.02 14-JAN-03:00 3359.63 09-JUL-17:00
Heating:EnergyTransfer:Zone:F2 NE APARTMENT 1.41 0.00 01-JAN-02:00 976.17 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT 30.93 0.00 01-JAN-00:15 3359.63 09-JUL-17:00
EnergyTransfer:Zone:F2 N1 APARTMENT 22.00 0.05 11-MAR-13:15 2273.85 02-JUL-17:45
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT 0.47 0.00 01-JAN-00:15 759.99 06-FEB-14:00
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT 21.53 0.00 01-JAN-11:30 2273.85 02-JUL-17:45
EnergyTransfer:Zone:F2 N2 APARTMENT 22.00 0.02 10-JAN-23:30 2263.94 02-JUL-17:45
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT 0.47 0.00 01-JAN-00:15 763.61 06-FEB-14:00
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT 21.54 0.00 01-JAN-11:30 2263.94 02-JUL-17:45
EnergyTransfer:Zone:F2 S1 APARTMENT 32.23 0.04 23-MAR-21:00 2879.36 15-OCT-12:15
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT 0.15 0.00 01-JAN-00:15 340.11 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT 32.08 0.00 01-JAN-17:30 2879.36 15-OCT-12:15
EnergyTransfer:Zone:F2 S2 APARTMENT 32.41 0.27 27-JAN-16:30 2894.26 15-OCT-12:30
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT 0.15 0.00 01-JAN-00:15 333.88 07-MAR-05:00
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT 32.25 0.00 01-JAN-17:30 2894.26 15-OCT-12:30
EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F3 SW APARTMENT 43.73 0.03 11-DEC-07:45 4464.20 08-OCT-14:30
Heating:EnergyTransfer:Zone:F3 SW APARTMENT 0.64 0.00 01-JAN-03:00 905.30 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT 43.09 0.00 01-JAN-00:15 4464.20 08-OCT-14:30
EnergyTransfer:Zone:F3 NW APARTMENT 34.09 0.05 22-NOV-22:45 4191.76 27-JUN-17:30
Heating:EnergyTransfer:Zone:F3 NW APARTMENT 1.65 0.00 01-JAN-07:15 929.70 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT 32.44 0.00 01-JAN-00:15 4191.76 27-JUN-17:30
EnergyTransfer:Zone:F3 SE APARTMENT 43.83 0.01 03-MAR-05:15 3958.99 14-OCT-12:45
Heating:EnergyTransfer:Zone:F3 SE APARTMENT 0.46 0.00 01-JAN-01:00 907.01 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT 43.37 0.00 01-JAN-00:15 3958.99 14-OCT-12:45
EnergyTransfer:Zone:F3 NE APARTMENT 33.57 0.01 07-DEC-02:30 3421.21 09-JUL-17:00
Heating:EnergyTransfer:Zone:F3 NE APARTMENT 1.25 0.00 01-JAN-01:00 942.85 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT 32.32 0.00 01-JAN-00:15 3421.21 09-JUL-17:00
EnergyTransfer:Zone:F3 N1 APARTMENT 23.36 0.31 15-FEB-01:45 2301.83 02-JUL-18:00
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT 0.38 0.00 01-JAN-00:15 745.88 06-FEB-14:00
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT 22.98 0.00 01-JAN-11:30 2301.83 02-JUL-18:00
EnergyTransfer:Zone:F3 N2 APARTMENT 23.37 0.15 08-DEC-01:15 2292.16 02-JUL-18:15
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT 0.38 0.00 01-JAN-00:15 752.06 06-FEB-14:00
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT 22.99 0.00 01-JAN-11:30 2292.16 02-JUL-18:15
EnergyTransfer:Zone:F3 S1 APARTMENT 34.16 0.18 21-NOV-09:00 2962.46 21-NOV-13:00
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT 0.13 0.00 01-JAN-00:15 245.09 07-MAR-05:00
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT 34.02 0.00 01-JAN-17:30 2962.46 21-NOV-13:00
EnergyTransfer:Zone:F3 S2 APARTMENT 34.20 1.14 18-OCT-06:00 2971.00 21-NOV-13:00
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT 0.14 0.00 01-JAN-00:15 244.41 07-MAR-05:00
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT 34.06 0.00 01-JAN-17:30 2971.00 21-NOV-13:00
EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F4 SW APARTMENT 44.16 0.02 01-JAN-03:00 4496.24 29-SEP-14:30
Heating:EnergyTransfer:Zone:F4 SW APARTMENT 0.64 0.00 01-JAN-03:15 925.63 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT 43.52 0.00 01-JAN-00:15 4496.24 29-SEP-14:30
EnergyTransfer:Zone:F4 NW APARTMENT 34.54 0.15 10-FEB-24:00 4234.18 27-JUN-17:30
Heating:EnergyTransfer:Zone:F4 NW APARTMENT 1.65 0.00 01-JAN-07:15 984.20 25-JAN-10:45
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT 32.89 0.00 01-JAN-00:15 4234.18 27-JUN-17:30
EnergyTransfer:Zone:F4 SE APARTMENT 44.03 0.00 30-JAN-21:15 3965.40 08-OCT-13:45
Heating:EnergyTransfer:Zone:F4 SE APARTMENT 0.47 0.00 01-JAN-01:00 937.92 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT 43.56 0.00 01-JAN-00:15 3965.40 08-OCT-13:45
EnergyTransfer:Zone:F4 NE APARTMENT 34.04 0.02 25-DEC-20:45 3475.41 09-JUL-17:00
Heating:EnergyTransfer:Zone:F4 NE APARTMENT 1.25 0.00 01-JAN-01:00 961.99 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT 32.79 0.00 01-JAN-00:15 3475.41 09-JUL-17:00
EnergyTransfer:Zone:F4 N1 APARTMENT 23.85 0.15 28-DEC-16:30 2340.21 02-JUL-18:30
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT 0.37 0.00 01-JAN-00:15 789.53 25-JAN-10:45
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT 23.49 0.00 01-JAN-11:30 2340.21 02-JUL-18:30
EnergyTransfer:Zone:F4 N2 APARTMENT 23.86 0.02 28-DEC-16:30 2330.92 02-JUL-18:30
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT 0.36 0.00 01-JAN-00:15 799.15 25-JAN-10:45
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT 23.49 0.00 01-JAN-11:30 2330.92 02-JUL-18:30
EnergyTransfer:Zone:F4 S1 APARTMENT 34.73 0.01 14-SEP-05:45 2992.96 21-NOV-13:00
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT 0.14 0.00 01-JAN-00:15 223.51 04-MAY-16:00
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT 34.59 0.00 01-JAN-17:30 2992.96 21-NOV-13:00
EnergyTransfer:Zone:F4 S2 APARTMENT 34.74 0.03 02-APR-01:30 2999.72 21-NOV-13:00
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT 0.14 0.00 01-JAN-00:15 295.30 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT 34.60 0.00 01-JAN-17:30 2999.72 21-NOV-13:00
EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M SW APARTMENT 44.74 0.00 31-JAN-20:45 4554.73 29-SEP-14:30
Heating:EnergyTransfer:Zone:M SW APARTMENT 0.68 0.00 01-JAN-03:15 945.03 07-MAR-03:00
Cooling:EnergyTransfer:Zone:M SW APARTMENT 44.06 0.00 01-JAN-00:15 4554.73 29-SEP-14:30
EnergyTransfer:Zone:M NW APARTMENT 35.26 0.04 11-APR-08:00 4287.79 27-JUN-17:30
Heating:EnergyTransfer:Zone:M NW APARTMENT 1.71 0.00 01-JAN-07:30 1074.92 25-JAN-10:45
Cooling:EnergyTransfer:Zone:M NW APARTMENT 33.56 0.00 01-JAN-00:15 4287.79 27-JUN-17:30
EnergyTransfer:Zone:M SE APARTMENT 44.57 0.02 17-FEB-06:00 4018.86 02-SEP-10:15
Heating:EnergyTransfer:Zone:M SE APARTMENT 0.50 0.00 01-JAN-01:00 959.86 07-MAR-03:00
Cooling:EnergyTransfer:Zone:M SE APARTMENT 44.07 0.00 01-JAN-00:15 4018.86 02-SEP-10:15
EnergyTransfer:Zone:M NE APARTMENT 34.75 0.00 08-DEC-05:45 3546.46 09-JUL-17:00
Heating:EnergyTransfer:Zone:M NE APARTMENT 1.30 0.00 01-JAN-01:00 980.95 07-MAR-03:00
Cooling:EnergyTransfer:Zone:M NE APARTMENT 33.46 0.00 01-JAN-00:15 3546.46 09-JUL-17:00
EnergyTransfer:Zone:M N1 APARTMENT 24.53 0.18 07-DEC-23:45 2402.56 02-JUL-18:45
Heating:EnergyTransfer:Zone:M N1 APARTMENT 0.38 0.00 01-JAN-00:15 858.39 25-JAN-10:45
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 24.14 0.00 01-JAN-11:30 2402.56 02-JUL-18:45
EnergyTransfer:Zone:M N2 APARTMENT 24.53 0.04 21-DEC-12:30 2393.38 02-JUL-18:45
Heating:EnergyTransfer:Zone:M N2 APARTMENT 0.38 0.00 01-JAN-00:15 864.97 25-JAN-10:45
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 24.15 0.00 01-JAN-11:30 2393.38 02-JUL-18:45
EnergyTransfer:Zone:M S1 APARTMENT 35.34 0.01 12-JAN-11:00 3028.73 21-NOV-13:30
Heating:EnergyTransfer:Zone:M S1 APARTMENT 0.15 0.00 01-JAN-00:15 237.76 04-MAY-16:00
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 35.20 0.00 01-JAN-17:30 3028.73 21-NOV-13:30
EnergyTransfer:Zone:M S2 APARTMENT 35.35 0.09 09-JAN-10:30 3033.10 21-NOV-13:30
Heating:EnergyTransfer:Zone:M S2 APARTMENT 0.15 0.00 01-JAN-00:15 238.22 04-MAY-16:00
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 35.20 0.00 01-JAN-17:30 3033.10 21-NOV-13:30
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F6 SW APARTMENT 43.94 0.00 23-DEC-01:30 4542.47 29-SEP-14:30
Heating:EnergyTransfer:Zone:F6 SW APARTMENT 0.78 0.00 01-JAN-03:15 1009.74 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT 43.16 0.00 01-JAN-00:15 4542.47 29-SEP-14:30
EnergyTransfer:Zone:F6 NW APARTMENT 34.90 0.02 06-DEC-01:15 4274.26 17-JUN-16:30
Heating:EnergyTransfer:Zone:F6 NW APARTMENT 1.89 0.00 01-JAN-07:45 1223.21 25-JAN-10:45
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT 33.01 0.00 01-JAN-00:15 4274.26 17-JUN-16:30
EnergyTransfer:Zone:F6 SE APARTMENT 43.73 0.00 05-FEB-00:45 4004.87 02-SEP-10:15
Heating:EnergyTransfer:Zone:F6 SE APARTMENT 0.58 0.00 01-JAN-01:00 1021.95 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT 43.15 0.00 01-JAN-00:15 4004.87 02-SEP-10:15
EnergyTransfer:Zone:F6 NE APARTMENT 34.34 0.04 24-JAN-10:15 3549.29 09-JUL-17:00
Heating:EnergyTransfer:Zone:F6 NE APARTMENT 1.46 0.00 01-JAN-01:00 1082.02 06-FEB-13:45
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT 32.88 0.00 01-JAN-00:15 3549.29 09-JUL-17:00
EnergyTransfer:Zone:F6 N1 APARTMENT 23.98 0.01 04-MAR-11:30 2391.33 02-JUL-19:00
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT 0.43 0.00 01-JAN-00:15 997.13 25-JAN-10:45
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT 23.56 0.00 01-JAN-11:30 2391.33 02-JUL-19:00
EnergyTransfer:Zone:F6 N2 APARTMENT 23.99 0.01 22-JAN-12:00 2382.42 02-JUL-19:00
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT 0.43 0.00 01-JAN-00:15 999.13 25-JAN-10:45
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT 23.56 0.00 01-JAN-11:30 2382.42 02-JUL-19:00
EnergyTransfer:Zone:F6 S1 APARTMENT 34.44 1.29 05-APR-01:00 2984.67 21-NOV-13:30
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT 0.16 0.00 01-JAN-00:15 269.53 07-MAR-05:00
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT 34.28 0.00 01-JAN-17:30 2984.67 21-NOV-13:30
EnergyTransfer:Zone:F6 S2 APARTMENT 34.44 0.67 14-SEP-06:15 2989.07 21-NOV-13:30
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT 0.16 0.00 01-JAN-00:15 272.55 07-MAR-05:00
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT 34.28 0.00 01-JAN-17:30 2989.07 21-NOV-13:30
EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F7 SW APARTMENT 43.62 0.00 24-NOV-05:15 4551.78 29-SEP-14:30
Heating:EnergyTransfer:Zone:F7 SW APARTMENT 0.86 0.00 01-JAN-03:15 1057.22 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT 42.76 0.00 01-JAN-00:15 4551.78 29-SEP-14:30
EnergyTransfer:Zone:F7 NW APARTMENT 34.91 0.21 09-NOV-06:15 4290.85 17-JUN-16:30
Heating:EnergyTransfer:Zone:F7 NW APARTMENT 2.05 0.00 01-JAN-08:30 1258.91 06-FEB-13:45
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT 32.86 0.00 01-JAN-00:15 4290.85 17-JUN-16:30
EnergyTransfer:Zone:F7 SE APARTMENT 43.40 0.03 21-DEC-07:00 4012.62 02-SEP-10:15
Heating:EnergyTransfer:Zone:F7 SE APARTMENT 0.65 0.00 01-JAN-01:00 1068.56 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT 42.74 0.00 01-JAN-00:15 4012.62 02-SEP-10:15
EnergyTransfer:Zone:F7 NE APARTMENT 34.33 0.03 11-MAR-03:45 3580.40 09-JUL-17:00
Heating:EnergyTransfer:Zone:F7 NE APARTMENT 1.61 0.00 01-JAN-02:15 1249.25 06-FEB-13:45
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT 32.73 0.00 01-JAN-00:15 3580.40 09-JUL-17:00
EnergyTransfer:Zone:F7 N1 APARTMENT 23.85 0.03 01-APR-22:15 2411.56 03-JUL-18:00
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT 0.48 0.00 01-JAN-00:15 1063.27 06-FEB-13:45
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT 23.37 0.00 01-JAN-11:30 2411.56 03-JUL-18:00
EnergyTransfer:Zone:F7 N2 APARTMENT 23.86 0.00 08-DEC-10:15 2402.63 03-JUL-18:00
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT 0.48 0.00 01-JAN-00:15 1068.13 06-FEB-13:45
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT 23.38 0.00 01-JAN-11:30 2402.63 03-JUL-18:00
EnergyTransfer:Zone:F7 S1 APARTMENT 34.04 0.23 02-APR-02:30 2960.86 21-NOV-13:30
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT 0.18 0.00 01-JAN-00:15 322.41 07-MAR-05:00
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT 33.86 0.00 01-JAN-11:30 2960.86 21-NOV-13:30
EnergyTransfer:Zone:F7 S2 APARTMENT 34.04 0.05 02-APR-02:45 2965.30 21-NOV-13:30
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT 0.18 0.00 01-JAN-00:15 324.68 07-MAR-05:00
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT 33.87 0.00 01-JAN-11:30 2965.30 21-NOV-13:30
EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F8 SW APARTMENT 43.57 0.09 06-DEC-01:45 4576.88 29-SEP-14:30
Heating:EnergyTransfer:Zone:F8 SW APARTMENT 0.95 0.00 01-JAN-03:30 1107.87 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT 42.62 0.00 01-JAN-00:15 4576.88 29-SEP-14:30
EnergyTransfer:Zone:F8 NW APARTMENT 35.17 0.27 20-JAN-04:15 4320.58 17-JUN-16:30
Heating:EnergyTransfer:Zone:F8 NW APARTMENT 2.21 0.00 01-JAN-08:45 1414.09 06-FEB-13:45
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT 32.96 0.00 01-JAN-00:15 4320.58 17-JUN-16:30
EnergyTransfer:Zone:F8 SE APARTMENT 43.32 0.02 24-NOV-01:00 4036.02 02-SEP-10:15
Heating:EnergyTransfer:Zone:F8 SE APARTMENT 0.73 0.00 01-JAN-01:00 1118.73 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT 42.60 0.00 01-JAN-00:15 4036.02 02-SEP-10:15
EnergyTransfer:Zone:F8 NE APARTMENT 34.58 0.02 30-OCT-04:45 3617.80 09-JUL-17:00
Heating:EnergyTransfer:Zone:F8 NE APARTMENT 1.76 0.00 01-JAN-02:30 1396.48 06-FEB-13:45
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT 32.82 0.00 01-JAN-00:15 3617.80 09-JUL-17:00
EnergyTransfer:Zone:F8 N1 APARTMENT 23.97 0.01 06-MAY-09:45 2436.17 03-JUL-18:00
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT 0.54 0.00 01-JAN-00:15 1211.42 06-FEB-13:45
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT 23.43 0.00 01-JAN-11:00 2436.17 03-JUL-18:00
EnergyTransfer:Zone:F8 N2 APARTMENT 23.98 0.06 09-JAN-24:00 2427.34 03-JUL-18:00
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT 0.54 0.00 01-JAN-00:15 1215.30 06-FEB-13:45
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT 23.44 0.00 01-JAN-11:30 2427.34 03-JUL-18:00
EnergyTransfer:Zone:F8 S1 APARTMENT 33.90 0.04 21-OCT-08:30 2965.26 27-FEB-13:00
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT 0.19 0.00 01-JAN-00:15 380.59 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT 33.71 0.00 01-JAN-11:30 2965.26 27-FEB-13:00
EnergyTransfer:Zone:F8 S2 APARTMENT 33.91 0.19 16-FEB-24:00 2970.94 27-FEB-13:00
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT 0.20 0.00 01-JAN-00:15 382.93 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT 33.71 0.00 01-JAN-11:30 2970.94 27-FEB-13:00
EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F9 SW APARTMENT 44.54 0.02 21-JAN-04:00 4716.30 29-SEP-14:30
Heating:EnergyTransfer:Zone:F9 SW APARTMENT 1.15 0.00 01-JAN-04:00 1228.47 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT 43.39 0.00 01-JAN-00:15 4716.30 29-SEP-14:30
EnergyTransfer:Zone:F9 NW APARTMENT 36.56 0.31 19-FEB-12:00 4473.38 17-JUN-16:45
Heating:EnergyTransfer:Zone:F9 NW APARTMENT 2.53 0.00 05-JAN-06:30 1585.13 06-FEB-13:45
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT 34.02 0.00 01-JAN-00:15 4473.38 17-JUN-16:45
EnergyTransfer:Zone:F9 SE APARTMENT 44.23 0.00 24-JAN-20:45 4134.32 02-SEP-10:15
Heating:EnergyTransfer:Zone:F9 SE APARTMENT 0.89 0.00 01-JAN-01:00 1242.57 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT 43.34 0.00 01-JAN-00:15 4134.32 02-SEP-10:15
EnergyTransfer:Zone:F9 NE APARTMENT 35.86 0.00 07-DEC-10:00 3729.20 09-JUL-17:00
Heating:EnergyTransfer:Zone:F9 NE APARTMENT 2.02 0.00 01-JAN-03:00 1559.04 06-FEB-13:45
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT 33.84 0.00 01-JAN-00:15 3729.20 09-JUL-17:00
EnergyTransfer:Zone:F9 N1 APARTMENT 24.98 0.03 27-OCT-19:30 2567.17 03-JUL-18:00
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT 0.67 0.00 01-JAN-00:15 1387.15 06-FEB-13:45
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT 24.30 0.00 01-JAN-10:45 2567.17 03-JUL-18:00
EnergyTransfer:Zone:F9 N2 APARTMENT 24.99 0.01 05-NOV-02:00 2565.76 03-JUL-18:00
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT 0.68 0.00 01-JAN-00:15 1389.59 06-FEB-13:45
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT 24.32 0.00 01-JAN-11:00 2565.76 03-JUL-18:00
EnergyTransfer:Zone:F9 S1 APARTMENT 34.56 0.17 09-FEB-07:00 3055.35 27-FEB-13:15
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT 0.24 0.00 01-JAN-00:15 504.06 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT 34.32 0.00 01-JAN-11:30 3055.35 27-FEB-13:15
EnergyTransfer:Zone:F9 S2 APARTMENT 34.56 0.16 03-APR-22:00 3061.82 27-FEB-13:15
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT 0.24 0.00 01-JAN-00:15 505.76 07-MAR-03:00
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT 34.33 0.00 01-JAN-11:30 3061.82 27-FEB-13:15
EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:T SW APARTMENT 50.17 0.01 18-FEB-23:45 5742.52 29-SEP-14:30
Heating:EnergyTransfer:Zone:T SW APARTMENT 2.97 0.00 01-JAN-09:15 1644.73 07-MAR-03:00
Cooling:EnergyTransfer:Zone:T SW APARTMENT 47.19 0.00 01-JAN-00:15 5742.52 29-SEP-14:30
EnergyTransfer:Zone:T NW APARTMENT 42.40 0.24 11-MAR-23:00 5404.48 17-JUN-16:30
Heating:EnergyTransfer:Zone:T NW APARTMENT 4.46 0.00 07-JAN-14:15 1853.56 11-JAN-08:45
Cooling:EnergyTransfer:Zone:T NW APARTMENT 37.94 0.00 01-JAN-00:15 5404.48 17-JUN-16:30
EnergyTransfer:Zone:T SE APARTMENT 49.48 0.33 28-FEB-03:30 5099.59 29-SEP-14:30
Heating:EnergyTransfer:Zone:T SE APARTMENT 2.59 0.00 01-JAN-08:15 1650.25 07-MAR-03:00
Cooling:EnergyTransfer:Zone:T SE APARTMENT 46.89 0.00 01-JAN-00:15 5099.59 29-SEP-14:30
EnergyTransfer:Zone:T NE APARTMENT 41.18 0.24 28-MAR-08:15 4478.03 09-JUL-17:00
Heating:EnergyTransfer:Zone:T NE APARTMENT 3.78 0.00 01-JAN-08:30 1697.18 07-FEB-06:00
Cooling:EnergyTransfer:Zone:T NE APARTMENT 37.40 0.00 01-JAN-00:15 4478.03 09-JUL-17:00
EnergyTransfer:Zone:T N1 APARTMENT 29.55 0.03 30-OCT-04:00 3376.49 02-JUL-17:30
Heating:EnergyTransfer:Zone:T N1 APARTMENT 1.73 0.00 01-JAN-01:00 1484.78 06-FEB-13:45
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 27.83 0.00 01-JAN-00:15 3376.49 02-JUL-17:30
EnergyTransfer:Zone:T N2 APARTMENT 29.57 0.00 27-NOV-03:30 3359.64 02-JUL-17:30
Heating:EnergyTransfer:Zone:T N2 APARTMENT 1.73 0.00 01-JAN-01:00 1480.47 06-FEB-13:45
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 27.84 0.00 01-JAN-00:15 3359.64 02-JUL-17:30
EnergyTransfer:Zone:T S1 APARTMENT 38.33 0.01 10-MAR-05:30 4036.36 08-OCT-13:30
Heating:EnergyTransfer:Zone:T S1 APARTMENT 0.89 0.00 01-JAN-01:00 904.07 07-MAR-03:00
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 37.44 0.00 01-JAN-00:15 4036.36 08-OCT-13:30
EnergyTransfer:Zone:T S2 APARTMENT 38.36 0.06 29-JAN-10:30 4042.20 08-OCT-13:30
Heating:EnergyTransfer:Zone:T S2 APARTMENT 0.90 0.00 01-JAN-02:30 905.03 07-MAR-03:00
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 37.46 0.00 01-JAN-00:15 4042.20 08-OCT-13:30
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Plant 666.99 299.55 27-JUL-01:15 91636.93 10-FEB-07:15
WaterSystems:EnergyTransfer 661.60 299.55 27-JUL-01:15 49186.81 25-JAN-08:00
sub cat:WaterSystems:EnergyTransfer 661.60 299.55 27-JUL-01:15 49186.81 25-JAN-08:00
EnergyTransfer:HVAC 3585.67 0.00 02-JAN-19:30 342248.30 10-AUG-16:00
CoolingCoils:EnergyTransfer 3558.80 0.00 01-JAN-01:15 342248.30 10-AUG-16:00
HeatingCoils:EnergyTransfer 26.86 0.00 01-JAN-09:45 68976.97 07-MAR-03:00
PlantLoopHeatingDemand:HVAC 20.61 0.00 01-JAN-09:45 52336.76 07-MAR-03:00
HeatingCoils:PlantLoopHeatingDemand 20.61 0.00 01-JAN-09:45 52336.76 07-MAR-03:00
Boilers:EnergyTransfer 5.39 0.00 01-JAN-00:15 47156.31 07-MAR-05:15



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:36

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 1.363 -29.612 0.000 0.000 3.627 1.087 12.213 32.534 0.000 1.547 0.001 0.000 -6.036 0.000 -4.483 -12.238
G NW APARTMENT 2.414 -22.593 0.000 0.000 3.671 1.087 12.213 19.880 0.000 1.546 0.000 0.000 -6.083 0.000 -3.754 -8.379
OFFICE 0.621 -41.430 0.000 0.000 0.504 29.882 9.495 32.097 0.000 1.433 0.000 0.000 -6.046 0.000 -1.191 -25.365
G NE APARTMENT 1.976 -22.211 0.000 0.000 3.681 1.087 12.213 19.423 0.000 1.547 0.000 0.000 -5.615 0.000 -3.772 -8.328
G N1 APARTMENT 0.926 -14.738 0.000 0.000 3.688 1.087 12.213 7.984 0.000 0.978 0.000 0.000 -3.649 0.000 -2.991 -5.498
G N2 APARTMENT 0.924 -14.745 0.000 0.000 3.688 1.087 12.213 7.983 0.000 0.978 0.000 0.000 -3.646 0.000 -2.992 -5.490
G S1 APARTMENT 0.265 -21.846 0.000 0.000 3.624 1.087 12.213 20.822 0.000 0.979 0.000 0.000 -3.631 0.000 -3.904 -9.608
G S2 APARTMENT 0.271 -22.272 0.000 0.000 3.620 1.087 12.213 20.805 0.000 0.979 0.000 0.000 -3.645 0.000 -3.938 -9.120
F2 SW APARTMENT 0.738 -41.525 0.000 0.000 3.566 1.087 12.213 31.618 0.000 2.183 2.392 0.000 -6.661 0.000 -5.611 -0.000
F2 NW APARTMENT 1.844 -31.101 0.000 0.000 3.620 1.087 12.213 19.261 0.000 2.181 2.493 0.000 -6.676 0.000 -4.920 -0.000
F2 SE APARTMENT 0.519 -43.681 0.000 0.000 3.563 1.087 12.213 31.376 0.000 2.185 4.923 0.000 -6.508 0.000 -5.676 -0.001
F2 NE APARTMENT 1.409 -30.930 0.000 0.000 3.632 1.087 12.213 18.783 0.000 2.182 2.646 0.000 -6.131 0.000 -4.890 -0.000
F2 N1 APARTMENT 0.469 -21.528 0.000 0.000 3.631 1.087 12.213 7.687 0.000 1.366 3.100 0.000 -4.053 0.000 -3.970 -0.000
F2 N2 APARTMENT 0.469 -21.536 0.000 0.000 3.632 1.087 12.213 7.686 0.000 1.366 3.103 0.000 -4.049 0.000 -3.969 -0.000
F2 S1 APARTMENT 0.153 -32.077 0.000 0.000 3.556 1.087 12.213 20.243 0.000 1.367 2.344 0.000 -4.018 0.000 -4.867 -0.000
F2 S2 APARTMENT 0.154 -32.253 0.000 0.000 3.555 1.087 12.213 20.240 0.000 1.367 2.535 0.000 -4.022 0.000 -4.875 -0.000
F3 SW APARTMENT 0.639 -43.093 0.000 0.000 3.558 1.087 12.213 31.208 0.000 2.598 4.722 0.000 -6.799 0.000 -6.132 -0.001
F3 NW APARTMENT 1.651 -32.435 0.000 0.000 3.609 1.087 12.213 19.025 0.000 2.594 4.569 0.000 -6.848 0.000 -5.465 -0.000
F3 SE APARTMENT 0.460 -43.374 0.000 0.000 3.562 1.087 12.213 31.028 0.000 2.599 5.143 0.000 -6.577 0.000 -6.141 -0.001
F3 NE APARTMENT 1.250 -32.316 0.000 0.000 3.621 1.087 12.213 18.548 0.000 2.595 4.715 0.000 -6.283 0.000 -5.429 -0.000
F3 N1 APARTMENT 0.382 -22.979 0.000 0.000 3.615 1.087 12.213 7.611 0.000 1.632 5.051 0.000 -4.184 0.000 -4.428 0.000
F3 N2 APARTMENT 0.382 -22.988 0.000 0.000 3.616 1.087 12.213 7.610 0.000 1.632 5.053 0.000 -4.179 0.000 -4.425 0.000
F3 S1 APARTMENT 0.135 -34.023 0.000 0.000 3.546 1.087 12.213 19.988 0.000 1.632 4.812 0.000 -4.113 0.000 -5.276 -0.000
F3 S2 APARTMENT 0.135 -34.061 0.000 0.000 3.546 1.087 12.213 19.986 0.000 1.632 4.852 0.000 -4.112 0.000 -5.278 -0.000
F4 SW APARTMENT 0.638 -43.523 0.000 0.000 3.557 1.087 12.213 30.921 0.000 2.884 5.350 0.000 -6.856 0.000 -6.270 -0.000
F4 NW APARTMENT 1.650 -32.893 0.000 0.000 3.605 1.087 12.213 18.872 0.000 2.879 5.161 0.000 -6.931 0.000 -5.643 0.000
F4 SE APARTMENT 0.468 -43.563 0.000 0.000 3.562 1.087 12.213 30.754 0.000 2.885 5.485 0.000 -6.620 0.000 -6.271 -0.000
F4 NE APARTMENT 1.247 -32.790 0.000 0.000 3.617 1.087 12.213 18.396 0.000 2.881 5.312 0.000 -6.355 0.000 -5.606 0.000
F4 N1 APARTMENT 0.366 -23.486 0.000 0.000 3.608 1.087 12.213 7.570 0.000 1.806 5.624 0.000 -4.250 0.000 -4.538 0.000
F4 N2 APARTMENT 0.364 -23.493 0.000 0.000 3.609 1.087 12.213 7.570 0.000 1.806 5.625 0.000 -4.245 0.000 -4.536 0.000
F4 S1 APARTMENT 0.136 -34.593 0.000 0.000 3.543 1.087 12.213 19.811 0.000 1.808 5.473 0.000 -4.153 0.000 -5.325 -0.000
F4 S2 APARTMENT 0.137 -34.601 0.000 0.000 3.544 1.087 12.213 19.811 0.000 1.808 5.481 0.000 -4.152 0.000 -5.326 -0.000
M SW APARTMENT 0.681 -44.062 0.000 0.000 3.557 1.087 12.213 30.681 0.000 3.116 6.210 0.000 -6.901 0.000 -6.581 -0.001
M NW APARTMENT 1.706 -33.558 0.000 0.000 3.604 1.087 12.213 18.744 0.000 3.111 6.025 0.000 -6.989 0.000 -5.942 0.000
M SE APARTMENT 0.504 -44.065 0.000 0.000 3.562 1.087 12.213 30.517 0.000 3.118 6.305 0.000 -6.661 0.000 -6.581 -0.001
M NE APARTMENT 1.295 -33.455 0.000 0.000 3.615 1.087 12.213 18.267 0.000 3.113 6.175 0.000 -6.407 0.000 -5.903 0.000
M N1 APARTMENT 0.382 -24.145 0.000 0.000 3.605 1.087 12.213 7.534 0.000 1.948 6.443 0.000 -4.295 0.000 -4.772 0.000
M N2 APARTMENT 0.380 -24.151 0.000 0.000 3.606 1.087 12.213 7.534 0.000 1.948 6.444 0.000 -4.290 0.000 -4.769 0.000
M S1 APARTMENT 0.147 -35.197 0.000 0.000 3.543 1.087 12.213 19.663 0.000 1.951 6.337 0.000 -4.183 0.000 -5.559 -0.000
M S2 APARTMENT 0.147 -35.200 0.000 0.000 3.543 1.087 12.213 19.663 0.000 1.951 6.338 0.000 -4.182 0.000 -5.559 -0.000
F6 SW APARTMENT 0.775 -43.160 0.000 0.000 3.561 1.087 12.213 30.514 0.000 3.314 5.408 0.000 -6.894 0.000 -6.818 -0.000
F6 NW APARTMENT 1.890 -33.006 0.000 0.000 3.610 1.087 12.213 18.677 0.000 3.308 5.319 0.000 -6.972 0.000 -6.126 0.000
F6 SE APARTMENT 0.583 -43.149 0.000 0.000 3.567 1.087 12.213 30.354 0.000 3.316 5.499 0.000 -6.651 0.000 -6.818 -0.000
F6 NE APARTMENT 1.458 -32.881 0.000 0.000 3.622 1.087 12.213 18.203 0.000 3.310 5.464 0.000 -6.389 0.000 -6.086 0.000
F6 N1 APARTMENT 0.429 -23.555 0.000 0.000 3.612 1.087 12.213 7.530 0.000 2.069 5.791 0.000 -4.285 0.000 -4.889 0.000
F6 N2 APARTMENT 0.428 -23.563 0.000 0.000 3.613 1.087 12.213 7.529 0.000 2.069 5.792 0.000 -4.280 0.000 -4.887 0.000
F6 S1 APARTMENT 0.162 -34.277 0.000 0.000 3.547 1.087 12.213 19.561 0.000 2.072 5.548 0.000 -4.182 0.000 -5.730 -0.001
F6 S2 APARTMENT 0.163 -34.278 0.000 0.000 3.547 1.087 12.213 19.561 0.000 2.072 5.547 0.000 -4.180 0.000 -5.730 -0.001
F7 SW APARTMENT 0.856 -42.761 0.000 0.000 3.565 1.087 12.213 30.356 0.000 3.487 5.108 0.000 -6.896 0.000 -7.014 -0.000
F7 NW APARTMENT 2.050 -32.863 0.000 0.000 3.615 1.087 12.213 18.607 0.000 3.480 5.065 0.000 -6.969 0.000 -6.285 0.000
F7 SE APARTMENT 0.653 -42.742 0.000 0.000 3.571 1.087 12.213 30.197 0.000 3.489 5.199 0.000 -6.653 0.000 -7.013 -0.000
F7 NE APARTMENT 1.606 -32.728 0.000 0.000 3.626 1.087 12.213 18.134 0.000 3.482 5.210 0.000 -6.385 0.000 -6.245 0.000
F7 N1 APARTMENT 0.478 -23.372 0.000 0.000 3.617 1.087 12.213 7.518 0.000 2.174 5.558 0.000 -4.283 0.000 -4.990 0.000
F7 N2 APARTMENT 0.480 -23.380 0.000 0.000 3.618 1.087 12.213 7.517 0.000 2.174 5.558 0.000 -4.278 0.000 -4.988 0.000
F7 S1 APARTMENT 0.177 -33.865 0.000 0.000 3.550 1.087 12.213 19.464 0.000 2.178 5.249 0.000 -4.186 0.000 -5.867 -0.000
F7 S2 APARTMENT 0.178 -33.866 0.000 0.000 3.550 1.087 12.213 19.463 0.000 2.178 5.248 0.000 -4.184 0.000 -5.867 -0.000
F8 SW APARTMENT 0.945 -42.621 0.000 0.000 3.568 1.087 12.213 30.209 0.000 3.644 5.074 0.000 -6.902 0.000 -7.216 -0.000
F8 NW APARTMENT 2.211 -32.962 0.000 0.000 3.619 1.087 12.213 18.537 0.000 3.637 5.085 0.000 -6.972 0.000 -6.454 0.000
F8 SE APARTMENT 0.727 -42.595 0.000 0.000 3.574 1.087 12.213 30.050 0.000 3.647 5.169 0.000 -6.657 0.000 -7.214 -0.000
F8 NE APARTMENT 1.759 -32.818 0.000 0.000 3.630 1.087 12.213 18.063 0.000 3.640 5.229 0.000 -6.387 0.000 -6.414 0.000
F8 N1 APARTMENT 0.539 -23.427 0.000 0.000 3.621 1.087 12.213 7.502 0.000 2.271 5.588 0.000 -4.284 0.000 -5.108 0.000
F8 N2 APARTMENT 0.541 -23.436 0.000 0.000 3.622 1.087 12.213 7.501 0.000 2.271 5.588 0.000 -4.280 0.000 -5.106 0.000
F8 S1 APARTMENT 0.195 -33.706 0.000 0.000 3.553 1.087 12.213 19.373 0.000 2.276 5.216 0.000 -4.190 0.000 -6.016 -0.000
F8 S2 APARTMENT 0.196 -33.709 0.000 0.000 3.553 1.087 12.213 19.372 0.000 2.276 5.217 0.000 -4.189 0.000 -6.017 -0.000
F9 SW APARTMENT 1.154 -43.390 0.000 0.000 3.572 1.087 12.213 30.057 0.000 3.791 5.804 0.000 -6.900 0.000 -7.388 -0.000
F9 NW APARTMENT 2.535 -34.021 0.000 0.000 3.621 1.087 12.213 18.449 0.000 3.783 5.916 0.000 -6.979 0.000 -6.603 -0.000
F9 SE APARTMENT 0.886 -43.339 0.000 0.000 3.578 1.087 12.213 29.897 0.000 3.793 5.922 0.000 -6.652 0.000 -7.385 -0.000
F9 NE APARTMENT 2.017 -33.842 0.000 0.000 3.632 1.087 12.213 17.976 0.000 3.785 6.091 0.000 -6.394 0.000 -6.564 0.000
F9 N1 APARTMENT 0.675 -24.304 0.000 0.000 3.623 1.087 12.213 7.471 0.000 2.362 6.374 0.000 -4.288 0.000 -5.213 0.000
F9 N2 APARTMENT 0.677 -24.316 0.000 0.000 3.624 1.087 12.213 7.470 0.000 2.362 6.378 0.000 -4.284 0.000 -5.211 0.000
F9 S1 APARTMENT 0.237 -34.320 0.000 0.000 3.558 1.087 12.213 19.281 0.000 2.369 5.905 0.000 -4.188 0.000 -6.140 -0.000
F9 S2 APARTMENT 0.238 -34.327 0.000 0.000 3.558 1.087 12.213 19.280 0.000 2.369 5.909 0.000 -4.186 0.000 -6.140 -0.000
T SW APARTMENT 2.974 -47.191 0.000 0.000 3.604 1.087 12.213 29.531 0.000 3.919 7.810 0.000 -6.556 0.000 -7.391 -0.000
T NW APARTMENT 4.464 -37.937 0.000 0.000 3.637 1.087 12.213 17.977 0.000 3.911 8.126 0.000 -6.711 0.000 -6.765 -0.000
T SE APARTMENT 2.594 -46.886 0.000 0.000 3.611 1.087 12.213 29.383 0.000 3.921 7.819 0.000 -6.329 0.000 -7.412 -0.000
T NE APARTMENT 3.775 -37.400 0.000 0.000 3.649 1.087 12.213 17.553 0.000 3.912 8.162 0.000 -6.184 0.000 -6.766 -0.000
T N1 APARTMENT 1.725 -27.826 0.000 0.000 3.639 1.087 12.213 7.277 0.000 2.441 8.917 0.000 -4.124 0.000 -5.349 -0.000
T N2 APARTMENT 1.734 -27.836 0.000 0.000 3.640 1.087 12.213 7.275 0.000 2.441 8.919 0.000 -4.120 0.000 -5.352 -0.000
T S1 APARTMENT 0.889 -37.443 0.000 0.000 3.590 1.087 12.213 18.992 0.000 2.448 8.360 0.000 -4.003 0.000 -6.133 -0.000
T S2 APARTMENT 0.896 -37.459 0.000 0.000 3.591 1.087 12.213 18.990 0.000 2.448 8.369 0.000 -4.001 0.000 -6.134 -0.000
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 7.095 0.000 16.182 0.000 0.000 -1.387 0.000 -17.050 -21.279
F2 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 3.464 0.000 0.251 0.000 0.000 -0.877 0.000 -0.342 -18.935
F3 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 3.398 0.000 0.296 0.000 0.000 -0.914 0.000 -0.424 -18.796
F4 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 3.348 0.000 0.326 0.000 0.000 -0.932 0.000 -0.482 -18.699
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 32.880 0.000 3.264 0.000 0.327 0.000 0.000 -0.977 0.000 -0.561 -34.933
F6 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 3.297 0.000 0.376 0.000 0.000 -0.939 0.000 -0.560 -18.615
F7 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 3.288 0.000 0.400 0.000 0.000 -0.932 0.000 -0.584 -18.612
F8 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 3.270 0.000 0.417 0.000 0.000 -0.931 0.000 -0.610 -18.585
F9 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 3.241 0.000 0.423 0.000 0.000 -0.935 0.000 -0.634 -18.535
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 8.151 3.065 0.000 0.341 0.000 0.000 -0.917 0.000 -0.691 -26.389
Total Facility 76.750 -2622.678 0.000 0.000 284.666 296.560 982.450 1567.113 0.000 217.337 399.756 0.000 -438.202 0.000 -466.346 -297.414


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 29-SEP-14:30 0.00 -3877.65 0.00 0.00 39.29 22.70 400.26 5017.68 0.00 142.24 0.00 0.00 0.00 0.00 0.00 -1744.52
G NW APARTMENT 02-JUL-17:20 0.00 -3651.03 0.00 0.00 138.17 87.56 588.62 3488.19 0.00 349.77 0.00 0.00 0.00 0.00 0.00 -1001.29
OFFICE 29-SEP-10:30 0.00 -5008.90 0.00 0.00 65.20 2345.88 588.62 4570.30 0.00 78.11 0.00 0.00 0.00 0.00 0.00 -2639.20
G NE APARTMENT 16-JUL-17:20 0.00 -2863.29 0.00 0.00 138.77 87.56 588.62 1964.91 0.00 438.02 0.00 0.00 0.00 0.00 0.00 -354.59
G N1 APARTMENT 02-JUL-17:20 0.00 -1960.41 0.00 0.00 140.43 87.56 588.62 1107.70 0.00 213.81 0.00 0.00 0.00 0.00 0.00 -177.70
G N2 APARTMENT 02-JUL-17:20 0.00 -1948.46 0.00 0.00 140.43 87.56 588.62 1107.97 0.00 213.81 0.00 0.00 0.00 0.00 0.00 -189.92
G S1 APARTMENT 01-OCT-11:45 0.00 -2402.12 0.00 0.00 40.54 12.97 406.15 3421.42 0.00 74.15 0.00 0.00 0.00 0.00 0.00 -1553.11
G S2 APARTMENT 01-OCT-12:00 0.00 -2462.11 0.00 0.00 40.44 12.97 406.15 3468.89 0.00 80.66 0.00 0.00 0.00 0.00 0.00 -1547.00
F2 SW APARTMENT 29-SEP-14:30 0.00 -4445.61 0.00 0.00 39.63 22.70 400.26 4959.16 0.00 206.00 0.00 0.00 0.00 0.00 0.00 -1182.13
F2 NW APARTMENT 02-JUL-17:20 0.00 -4172.57 0.00 0.00 139.31 87.56 588.62 3422.44 0.00 505.80 0.00 0.00 0.00 0.00 0.00 -571.17
F2 SE APARTMENT 02-SEP-11:00 0.00 -4125.64 0.00 0.00 40.70 12.97 412.03 3844.42 0.00 372.58 0.00 0.00 0.00 0.00 0.00 -557.07
F2 NE APARTMENT 09-JUL-17:00 0.00 -3359.46 0.00 0.00 83.99 64.86 588.62 1444.71 0.00 829.28 348.00 0.00 0.00 0.00 0.00 0.00
F2 N1 APARTMENT 02-JUL-17:45 0.00 -2274.15 0.00 0.00 140.26 87.56 588.62 1105.47 0.00 304.44 47.81 0.00 0.00 0.00 0.00 0.00
F2 N2 APARTMENT 02-JUL-17:45 0.00 -2264.23 0.00 0.00 140.26 87.56 588.62 1105.40 0.00 304.45 37.94 0.00 0.00 0.00 0.00 0.00
F2 S1 APARTMENT 15-OCT-12:15 0.00 -2879.30 0.00 0.00 40.75 12.97 388.49 3195.42 0.00 24.95 0.00 0.00 0.00 0.00 0.00 -783.28
F2 S2 APARTMENT 15-OCT-12:30 0.00 -2894.09 0.00 0.00 40.75 12.97 388.49 3153.87 0.00 32.12 0.00 0.00 0.00 0.00 0.00 -734.10
F3 SW APARTMENT 08-OCT-14:30 0.00 -4464.07 0.00 0.00 40.63 22.70 400.26 4762.10 0.00 217.50 0.00 0.00 0.00 0.00 0.00 -979.12
F3 NW APARTMENT 27-JUN-17:20 0.00 -4203.45 0.00 0.00 139.65 87.56 588.62 3613.46 0.00 368.35 0.00 0.00 0.00 0.00 0.00 -594.19
F3 SE APARTMENT 14-OCT-12:45 0.00 -3958.95 0.00 0.00 40.74 12.97 388.49 3789.72 0.00 235.51 0.00 0.00 0.00 0.00 0.00 -508.47
F3 NE APARTMENT 09-JUL-17:00 0.00 -3421.02 0.00 0.00 83.51 64.86 588.62 1449.08 0.00 974.69 260.26 0.00 0.00 0.00 0.00 0.00
F3 N1 APARTMENT 02-JUL-18:00 0.00 -2302.22 0.00 0.00 139.73 87.56 588.62 1078.31 0.00 356.24 51.77 0.00 0.00 0.00 0.00 0.00
F3 N2 APARTMENT 02-JUL-18:15 0.00 -2292.46 0.00 0.00 139.79 103.77 547.42 1028.96 0.00 366.94 105.58 0.00 0.00 0.00 0.00 0.00
F3 S1 APARTMENT 21-NOV-13:00 0.00 -2962.53 0.00 0.00 40.75 12.97 406.15 3345.65 0.00 0.00 0.00 0.00 0.00 0.00 -2.50 -840.49
F3 S2 APARTMENT 21-NOV-13:00 0.00 -2971.07 0.00 0.00 40.75 12.97 406.15 3345.53 0.00 0.00 0.00 0.00 0.00 0.00 -2.46 -831.87
F4 SW APARTMENT 29-SEP-14:30 0.00 -4496.26 0.00 0.00 39.80 22.70 400.26 4896.23 0.00 272.86 0.00 0.00 0.00 0.00 0.00 -1135.59
F4 NW APARTMENT 27-JUN-17:20 0.00 -4237.65 0.00 0.00 139.67 87.56 588.62 3591.80 0.00 411.26 0.00 0.00 0.00 0.00 0.00 -581.25
F4 SE APARTMENT 08-OCT-13:45 0.00 -3965.25 0.00 0.00 40.63 12.97 382.60 3668.03 0.00 207.76 0.00 0.00 0.00 0.00 0.00 -346.75
F4 NE APARTMENT 09-JUL-17:00 0.00 -3475.20 0.00 0.00 83.12 64.86 588.62 1450.44 0.00 1082.83 205.33 0.00 0.00 0.00 0.00 0.00
F4 N1 APARTMENT 02-JUL-18:30 0.00 -2340.38 0.00 0.00 139.77 103.77 547.42 932.24 0.00 420.74 196.44 0.00 0.00 0.00 0.00 0.00
F4 N2 APARTMENT 02-JUL-18:30 0.00 -2331.09 0.00 0.00 139.81 103.77 547.42 932.59 0.00 420.83 186.68 0.00 0.00 0.00 0.00 0.00
F4 S1 APARTMENT 21-NOV-13:00 0.00 -2993.02 0.00 0.00 40.75 12.97 406.15 3330.67 0.00 0.00 0.00 0.00 0.00 0.00 -3.17 -794.34
F4 S2 APARTMENT 21-NOV-13:00 0.00 -2999.78 0.00 0.00 40.75 12.97 406.15 3330.56 0.00 0.00 0.00 0.00 0.00 0.00 -3.16 -787.49
M SW APARTMENT 29-SEP-14:30 0.00 -4554.73 0.00 0.00 39.89 22.70 400.26 4874.47 0.00 296.81 0.00 0.00 0.00 0.00 0.00 -1079.41
M NW APARTMENT 27-JUN-17:20 0.00 -4291.22 0.00 0.00 139.72 87.56 588.62 3573.46 0.00 446.52 0.00 0.00 0.00 0.00 0.00 -544.66
M SE APARTMENT 02-SEP-10:15 0.00 -4018.49 0.00 0.00 40.65 12.97 412.03 3586.86 0.00 618.00 0.00 0.00 0.00 0.00 0.00 -652.03
M NE APARTMENT 09-JUL-17:00 0.00 -3546.23 0.00 0.00 82.83 64.86 588.62 1450.13 0.00 1170.88 188.91 0.00 0.00 0.00 0.00 0.00
M N1 APARTMENT 02-JUL-18:45 0.00 -2402.64 0.00 0.00 140.01 103.77 547.42 883.24 0.00 468.25 259.96 0.00 0.00 0.00 0.00 0.00
M N2 APARTMENT 02-JUL-18:45 0.00 -2393.45 0.00 0.00 140.04 103.77 547.42 883.59 0.00 468.33 250.30 0.00 0.00 0.00 0.00 0.00
M S1 APARTMENT 21-NOV-13:30 0.00 -3028.61 0.00 0.00 40.75 12.97 388.49 3204.43 0.00 14.94 0.00 0.00 0.00 0.00 0.00 -632.97
M S2 APARTMENT 21-NOV-13:30 0.00 -3032.98 0.00 0.00 40.75 12.97 388.49 3204.34 0.00 14.94 0.00 0.00 0.00 0.00 0.00 -628.51
F6 SW APARTMENT 29-SEP-14:30 0.00 -4542.45 0.00 0.00 39.95 22.70 400.26 4857.04 0.00 317.16 0.00 0.00 0.00 0.00 0.00 -1094.66
F6 NW APARTMENT 17-JUN-16:30 0.00 -4277.17 0.00 0.00 84.33 64.86 588.62 3305.59 0.00 715.74 0.00 0.00 0.00 0.00 0.00 -481.96
F6 SE APARTMENT 02-SEP-10:15 0.00 -4004.46 0.00 0.00 40.67 12.97 412.03 3547.91 0.00 659.77 0.00 0.00 0.00 0.00 0.00 -668.90
F6 NE APARTMENT 09-JUL-17:00 0.00 -3549.06 0.00 0.00 82.53 64.86 588.62 1450.68 0.00 1245.07 117.30 0.00 0.00 0.00 0.00 0.00
F6 N1 APARTMENT 02-JUL-19:00 0.00 -2391.32 0.00 0.00 140.08 103.77 547.42 787.11 0.00 511.39 301.56 0.00 0.00 0.00 0.00 0.00
F6 N2 APARTMENT 02-JUL-19:00 0.00 -2382.41 0.00 0.00 140.11 103.77 547.42 787.43 0.00 511.46 292.23 0.00 0.00 0.00 0.00 0.00
F6 S1 APARTMENT 21-NOV-13:30 0.00 -2984.55 0.00 0.00 40.75 12.97 388.49 3193.99 0.00 14.29 0.00 0.00 0.00 0.00 0.00 -665.95
F6 S2 APARTMENT 21-NOV-13:30 0.00 -2988.95 0.00 0.00 40.75 12.97 388.49 3193.90 0.00 14.29 0.00 0.00 0.00 0.00 0.00 -661.46
F7 SW APARTMENT 29-SEP-14:30 0.00 -4551.74 0.00 0.00 40.01 22.70 400.26 4841.39 0.00 335.17 0.00 0.00 0.00 0.00 0.00 -1087.80
F7 NW APARTMENT 17-JUN-16:30 0.00 -4293.89 0.00 0.00 84.31 64.86 588.62 3288.28 0.00 755.40 0.00 0.00 0.00 0.00 0.00 -487.58
F7 SE APARTMENT 02-SEP-10:15 0.00 -4012.18 0.00 0.00 40.69 12.97 412.03 3514.18 0.00 696.60 0.00 0.00 0.00 0.00 0.00 -664.30
F7 NE APARTMENT 09-JUL-17:00 0.00 -3580.15 0.00 0.00 82.35 64.86 588.62 1450.87 0.00 1311.13 82.32 0.00 0.00 0.00 0.00 0.00
F7 N1 APARTMENT 03-JUL-18:00 0.00 -2411.97 0.00 0.00 140.48 87.56 588.62 1022.82 0.00 515.43 57.07 0.00 0.00 0.00 0.00 0.00
F7 N2 APARTMENT 03-JUL-18:00 0.00 -2403.04 0.00 0.00 140.48 87.56 588.62 1023.04 0.00 515.47 47.88 0.00 0.00 0.00 0.00 0.00
F7 S1 APARTMENT 21-NOV-13:30 0.00 -2960.74 0.00 0.00 40.75 12.97 388.49 3184.11 0.00 13.44 0.00 0.00 0.00 0.00 0.00 -679.03
F7 S2 APARTMENT 21-NOV-13:30 0.00 -2965.18 0.00 0.00 40.75 12.97 388.49 3184.02 0.00 13.44 0.00 0.00 0.00 0.00 0.00 -674.50
F8 SW APARTMENT 29-SEP-14:30 0.00 -4576.82 0.00 0.00 40.08 22.70 400.26 4827.40 0.00 351.53 0.00 0.00 0.00 0.00 0.00 -1065.15
F8 NW APARTMENT 17-JUN-16:30 0.00 -4325.33 0.00 0.00 84.29 64.86 588.62 3272.60 0.00 790.96 0.00 0.00 0.00 0.00 0.00 -475.99
F8 SE APARTMENT 02-SEP-10:15 0.00 -4035.55 0.00 0.00 40.71 12.97 412.03 3484.34 0.00 729.79 0.00 0.00 0.00 0.00 0.00 -644.30
F8 NE APARTMENT 09-JUL-17:00 0.00 -3617.54 0.00 0.00 82.16 64.86 588.62 1449.76 0.00 1369.55 62.60 0.00 0.00 0.00 0.00 0.00
F8 N1 APARTMENT 03-JUL-18:00 0.00 -2436.58 0.00 0.00 140.39 87.56 588.62 1022.36 0.00 539.41 58.24 0.00 0.00 0.00 0.00 0.00
F8 N2 APARTMENT 03-JUL-18:00 0.00 -2427.75 0.00 0.00 140.39 87.56 588.62 1022.59 0.00 539.46 49.13 0.00 0.00 0.00 0.00 0.00
F8 S1 APARTMENT 27-FEB-13:00 0.00 -2965.59 0.00 0.00 40.55 12.97 406.15 3433.94 0.00 47.92 0.00 0.00 0.00 0.00 0.00 -975.95
F8 S2 APARTMENT 27-FEB-13:00 0.00 -2971.28 0.00 0.00 40.54 12.97 406.15 3433.67 0.00 47.88 0.00 0.00 0.00 0.00 0.00 -969.93
F9 SW APARTMENT 29-SEP-14:30 0.00 -4716.23 0.00 0.00 40.25 22.70 400.26 4814.39 0.00 367.54 0.00 0.00 0.00 0.00 0.00 -928.92
F9 NW APARTMENT 17-JUN-16:30 0.00 -4476.89 0.00 0.00 84.33 64.86 588.62 3254.84 0.00 823.79 0.00 0.00 0.00 0.00 0.00 -339.55
F9 SE APARTMENT 02-SEP-10:15 0.00 -4133.82 0.00 0.00 40.75 12.97 412.03 3456.42 0.00 761.47 0.00 0.00 0.00 0.00 0.00 -549.83
F9 NE APARTMENT 09-JUL-17:00 0.00 -3728.93 0.00 0.00 81.80 64.86 588.62 1442.33 0.00 1419.64 131.68 0.00 0.00 0.00 0.00 0.00
F9 N1 APARTMENT 03-JUL-18:00 0.00 -2567.58 0.00 0.00 140.46 87.56 588.62 1019.72 0.00 561.77 169.46 0.00 0.00 0.00 0.00 0.00
F9 N2 APARTMENT 03-JUL-18:00 0.00 -2566.18 0.00 0.00 140.55 87.56 588.62 1020.22 0.00 562.14 167.09 0.00 0.00 0.00 0.00 0.00
F9 S1 APARTMENT 27-FEB-13:15 0.00 -3055.66 0.00 0.00 40.70 12.97 388.49 3421.67 0.00 55.55 0.00 0.00 0.00 0.00 0.00 -863.72
F9 S2 APARTMENT 27-FEB-13:15 0.00 -3062.13 0.00 0.00 40.70 12.97 388.49 3421.45 0.00 55.52 0.00 0.00 0.00 0.00 0.00 -856.99
T SW APARTMENT 29-SEP-14:30 0.00 -5742.46 0.00 0.00 40.26 22.70 400.26 4744.34 0.00 380.76 154.14 0.00 0.00 0.00 0.00 0.00
T NW APARTMENT 17-JUN-16:30 0.00 -5406.05 0.00 0.00 84.59 64.86 588.62 3192.22 0.00 856.70 619.07 0.00 0.00 0.00 0.00 0.00
T SE APARTMENT 29-SEP-14:30 0.00 -5099.47 0.00 0.00 40.25 22.70 400.26 3373.17 0.00 383.87 879.22 0.00 0.00 0.00 0.00 0.00
T NE APARTMENT 09-JUL-17:00 0.00 -4477.73 0.00 0.00 82.81 64.86 588.62 1409.39 0.00 1489.94 842.12 0.00 0.00 0.00 0.00 0.00
T N1 APARTMENT 02-JUL-17:30 0.00 -3379.34 0.00 0.00 141.81 87.56 588.62 1087.34 0.00 565.15 908.88 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 02-JUL-17:30 0.00 -3359.94 0.00 0.00 141.81 87.56 588.62 1087.84 0.00 565.35 888.77 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 08-OCT-13:30 0.00 -4036.37 0.00 0.00 39.65 12.97 382.60 3187.60 0.00 138.15 275.39 0.00 0.00 0.00 0.00 0.00
T S2 APARTMENT 08-OCT-13:30 0.00 -4042.22 0.00 0.00 39.64 12.97 382.60 3187.28 0.00 138.11 281.61 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 09-JUL-17:00 0.00 -257356.22 0.00 0.00 6575.65 11327.17 47212.47 110341.63 0.00 82697.68 0.00 0.00 0.00 0.00 0.00 -798.38


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 07-MAR-03:00 1026.04 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 95.43 0.00 -1325.64 0.00 -221.55 0.00
G NW APARTMENT 25-JAN-10:40 1236.00 0.00 0.00 0.00 46.68 12.97 406.15 86.80 0.00 0.00 0.00 0.00 0.00 0.00 -1191.67 -596.93
OFFICE 07-MAR-03:00 852.67 0.00 0.00 0.00 0.00 469.18 194.24 0.00 0.00 0.00 51.15 0.00 -1345.69 0.00 -221.55 0.00
G NE APARTMENT 21-DEC-13:00 1059.85 0.00 0.00 0.00 44.23 12.97 406.15 124.99 0.00 0.00 0.00 0.00 0.00 0.00 -1352.82 -295.37
G N1 APARTMENT 06-FEB-10:55 1186.77 0.00 0.00 0.00 46.05 12.97 406.15 174.23 0.00 0.00 0.00 0.00 0.00 0.00 -1246.30 -579.87
G N2 APARTMENT 06-FEB-10:55 1182.56 0.00 0.00 0.00 46.05 12.97 406.15 174.09 0.00 0.00 0.00 0.00 0.00 0.00 -1246.39 -575.42
G S1 APARTMENT 07-MAR-03:00 467.70 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 50.22 0.00 -810.01 0.00 -133.63 0.00
G S2 APARTMENT 07-MAR-03:00 451.74 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 67.13 0.00 -810.96 0.00 -133.63 0.00
F2 SW APARTMENT 07-MAR-03:00 933.48 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 305.54 0.00 -1345.96 0.00 -318.78 0.00
F2 NW APARTMENT 06-FEB-11:00 1152.78 0.00 0.00 0.00 44.12 12.97 406.15 194.32 0.00 0.00 0.00 0.00 0.00 0.00 -1603.50 -206.83
F2 SE APARTMENT 07-MAR-03:00 873.41 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 372.05 0.00 -1352.39 0.00 -318.78 0.00
F2 NE APARTMENT 07-MAR-03:00 975.98 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 257.48 0.00 -1340.39 0.00 -318.78 0.00
F2 N1 APARTMENT 06-FEB-11:00 1235.34 0.00 0.00 0.00 44.35 12.97 406.15 124.34 0.00 0.00 0.00 0.00 0.00 0.00 -1494.49 -328.65
F2 N2 APARTMENT 06-FEB-11:00 1231.90 0.00 0.00 0.00 44.37 12.97 406.15 124.55 0.00 0.00 0.00 0.00 0.00 0.00 -1494.42 -325.52
F2 S1 APARTMENT 07-MAR-03:00 340.04 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 252.87 0.00 -826.35 0.00 -192.28 0.00
F2 S2 APARTMENT 07-MAR-05:00 333.85 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 224.91 0.00 -825.48 0.00 -166.09 0.00
F3 SW APARTMENT 07-MAR-03:00 905.13 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 404.71 0.00 -1357.73 0.00 -377.83 0.00
F3 NW APARTMENT 06-FEB-11:00 1295.65 0.00 0.00 0.00 43.67 12.97 406.15 156.28 0.00 0.00 0.00 0.00 0.00 0.00 -1795.64 -119.07
F3 SE APARTMENT 07-MAR-03:00 906.83 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 402.82 0.00 -1357.55 0.00 -377.83 0.00
F3 NE APARTMENT 21-DEC-13:00 1194.94 0.00 0.00 0.00 42.55 12.97 406.15 13.33 0.00 0.00 206.14 0.00 0.00 0.00 -1876.08 0.00
F3 N1 APARTMENT 21-DEC-13:00 1661.74 0.00 0.00 0.00 42.79 12.97 406.15 12.85 0.00 0.00 0.00 0.00 0.00 0.00 -1731.68 -404.81
F3 N2 APARTMENT 21-DEC-13:00 1613.46 0.00 0.00 0.00 42.77 12.97 406.15 12.58 0.00 0.00 0.00 0.00 0.00 0.00 -1732.64 -355.28
F3 S1 APARTMENT 07-MAR-05:00 245.07 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 352.52 0.00 -833.54 0.00 -196.85 0.00
F3 S2 APARTMENT 07-MAR-05:00 244.39 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 353.22 0.00 -833.57 0.00 -196.85 0.00
F4 SW APARTMENT 07-MAR-03:00 925.46 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 434.43 0.00 -1362.85 0.00 -422.76 0.00
F4 NW APARTMENT 02-JAN-10:45 1400.70 0.00 0.00 0.00 43.76 12.97 406.15 0.00 0.00 0.00 0.00 0.00 -14.22 0.00 -1759.65 -89.70
F4 SE APARTMENT 07-MAR-03:00 937.74 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 420.65 0.00 -1361.35 0.00 -422.76 0.00
F4 NE APARTMENT 06-FEB-12:15 1001.16 0.00 0.00 0.00 42.93 12.97 406.15 296.06 0.00 0.00 59.70 0.00 0.00 0.00 -1818.97 0.00
F4 N1 APARTMENT 02-JAN-10:45 1445.51 0.00 0.00 0.00 43.42 12.97 406.15 0.00 0.00 0.00 0.00 0.00 -23.49 0.00 -1637.88 -246.68
F4 N2 APARTMENT 02-JAN-10:45 1471.16 0.00 0.00 0.00 43.42 12.97 406.15 0.00 0.00 0.00 0.00 0.00 -23.68 0.00 -1637.44 -272.57
F4 S1 APARTMENT 04-MAY-15:55 228.85 0.00 0.00 0.00 48.90 45.40 470.89 33.04 0.00 0.00 468.62 0.00 0.00 0.00 -1295.71 0.00
F4 S2 APARTMENT 07-MAR-03:00 295.24 0.00 0.00 0.00 190.95 6.49 229.56 0.00 0.00 0.00 366.74 0.00 -834.41 0.00 -254.56 0.00
M SW APARTMENT 07-MAR-03:00 944.85 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 455.91 0.00 -1366.55 0.00 -459.93 0.00
M NW APARTMENT 02-JAN-10:45 1678.48 0.00 0.00 0.00 43.83 12.97 406.15 0.00 0.00 0.00 0.00 0.00 -27.05 0.00 -1867.60 -246.78
M SE APARTMENT 07-MAR-03:00 959.68 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 439.36 0.00 -1364.83 0.00 -459.93 0.00
M NE APARTMENT 06-FEB-12:15 1362.80 0.00 0.00 0.00 43.07 12.97 406.15 279.46 0.00 0.00 0.00 0.00 0.00 0.00 -1929.63 -174.82
M N1 APARTMENT 02-JAN-10:45 1713.51 0.00 0.00 0.00 43.38 12.97 406.15 0.00 0.00 0.00 0.00 0.00 -33.73 0.00 -1738.23 -404.05
M N2 APARTMENT 02-JAN-10:45 1695.03 0.00 0.00 0.00 43.38 12.97 406.15 0.00 0.00 0.00 0.00 0.00 -33.90 0.00 -1738.18 -385.45
M S1 APARTMENT 04-MAY-15:55 244.55 0.00 0.00 0.00 48.90 45.40 470.89 27.68 0.00 0.00 542.44 0.00 0.00 0.00 -1379.86 0.00
M S2 APARTMENT 04-MAY-15:55 244.99 0.00 0.00 0.00 48.90 45.40 470.89 27.60 0.00 0.00 543.25 0.00 0.00 0.00 -1381.03 0.00
F6 SW APARTMENT 07-MAR-03:00 1009.56 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 421.89 0.00 -1365.09 0.00 -492.07 0.00
F6 NW APARTMENT 25-JAN-10:40 1858.78 0.00 0.00 0.00 45.86 12.97 406.15 0.00 0.00 0.00 0.00 0.00 -33.11 0.00 -1850.26 -440.39
F6 SE APARTMENT 07-MAR-03:00 1021.76 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 408.18 0.00 -1363.58 0.00 -492.07 0.00
F6 NE APARTMENT 06-FEB-12:15 1670.77 0.00 0.00 0.00 43.54 12.97 406.15 274.71 0.00 0.00 0.00 0.00 0.00 0.00 -2025.75 -382.39
F6 N1 APARTMENT 21-DEC-13:15 1729.54 0.00 0.00 0.00 43.02 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -6.63 0.00 -1954.83 -212.55
F6 N2 APARTMENT 21-DEC-13:15 1738.04 0.00 0.00 0.00 43.00 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -6.89 0.00 -1954.84 -220.77
F6 S1 APARTMENT 07-MAR-05:00 269.50 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 392.53 0.00 -838.46 0.00 -256.37 0.00
F6 S2 APARTMENT 07-MAR-05:00 272.53 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 389.36 0.00 -838.32 0.00 -256.37 0.00
F7 SW APARTMENT 07-MAR-03:00 1057.02 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 402.54 0.00 -1364.62 0.00 -520.66 0.00
F7 NW APARTMENT 25-JAN-10:55 1745.91 0.00 0.00 0.00 45.75 12.97 406.15 0.00 0.00 0.00 0.00 0.00 -9.76 0.00 -1852.75 -348.26
F7 SE APARTMENT 07-MAR-03:00 1068.36 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 389.87 0.00 -1363.28 0.00 -520.66 0.00
F7 NE APARTMENT 06-FEB-12:15 1686.89 0.00 0.00 0.00 43.89 12.97 406.15 269.93 0.00 0.00 0.00 0.00 0.00 0.00 -2121.38 -298.45
F7 N1 APARTMENT 21-DEC-13:15 1699.11 0.00 0.00 0.00 43.29 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -7.72 0.00 -2045.73 -90.40
F7 N2 APARTMENT 21-DEC-13:15 1701.73 0.00 0.00 0.00 43.27 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -7.96 0.00 -2045.73 -92.76
F7 S1 APARTMENT 07-MAR-05:00 322.38 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 353.88 0.00 -837.80 0.00 -271.26 0.00
F7 S2 APARTMENT 07-MAR-05:00 324.65 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 351.50 0.00 -837.69 0.00 -271.26 0.00
F8 SW APARTMENT 07-MAR-03:00 1107.67 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 376.77 0.00 -1363.59 0.00 -546.56 0.00
F8 NW APARTMENT 25-JAN-10:55 2009.08 0.00 0.00 0.00 45.95 12.97 406.15 0.00 0.00 0.00 0.00 0.00 -11.72 0.00 -1918.99 -543.43
F8 SE APARTMENT 07-MAR-03:00 1118.53 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 364.61 0.00 -1362.29 0.00 -546.56 0.00
F8 NE APARTMENT 06-FEB-12:15 1710.24 0.00 0.00 0.00 44.18 12.97 406.15 265.55 0.00 0.00 0.00 0.00 0.00 0.00 -2209.81 -229.28
F8 N1 APARTMENT 25-JAN-10:55 1768.76 0.00 0.00 0.00 45.63 12.97 406.15 0.00 0.00 0.00 0.00 0.00 -22.22 0.00 -1788.24 -423.06
F8 N2 APARTMENT 25-JAN-10:55 1787.03 0.00 0.00 0.00 45.64 12.97 406.15 0.00 0.00 0.00 0.00 0.00 -22.20 0.00 -1787.90 -441.69
F8 S1 APARTMENT 07-MAR-03:00 380.51 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 361.79 0.00 -838.34 0.00 -329.67 0.00
F8 S2 APARTMENT 07-MAR-03:00 382.85 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 359.33 0.00 -838.23 0.00 -329.67 0.00
F9 SW APARTMENT 07-MAR-03:00 1228.25 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 273.02 0.00 -1356.62 0.00 -570.36 0.00
F9 NW APARTMENT 06-FEB-12:10 2186.60 0.00 0.00 0.00 45.10 12.97 406.15 165.80 0.00 0.00 0.00 0.00 0.00 0.00 -2313.57 -503.05
F9 SE APARTMENT 07-MAR-03:00 1242.34 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 257.81 0.00 -1355.50 0.00 -570.36 0.00
F9 NE APARTMENT 06-FEB-12:10 1923.00 0.00 0.00 0.00 44.58 12.97 406.15 266.03 0.00 0.00 0.00 0.00 0.00 0.00 -2325.70 -327.03
F9 N1 APARTMENT 25-JAN-10:55 2020.21 0.00 0.00 0.00 45.95 12.97 406.15 0.00 0.00 0.00 0.00 0.00 -20.48 0.00 -1845.01 -619.78
F9 N2 APARTMENT 25-JAN-10:55 2022.55 0.00 0.00 0.00 45.96 12.97 406.15 0.00 0.00 0.00 0.00 0.00 -20.50 0.00 -1844.99 -622.13
F9 S1 APARTMENT 07-MAR-03:00 503.96 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 247.60 0.00 -833.25 0.00 -344.03 0.00
F9 S2 APARTMENT 07-MAR-03:00 505.65 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 245.79 0.00 -833.13 0.00 -344.03 0.00
T SW APARTMENT 07-MAR-03:00 1644.45 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 0.00 0.00 -1325.27 0.00 -592.43 -152.46
T NW APARTMENT 11-JAN-08:40 2436.96 0.00 0.00 0.00 72.00 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -308.89 0.00 -2414.73 -193.28
T SE APARTMENT 07-MAR-03:00 1649.96 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 0.00 0.00 -1324.88 0.00 -592.43 -158.37
T NE APARTMENT 06-FEB-12:15 1982.40 0.00 0.00 0.00 43.36 12.97 406.15 225.25 0.00 0.00 0.00 0.00 0.00 0.00 -2379.40 -290.73
T N1 APARTMENT 11-JAN-08:40 2298.28 0.00 0.00 0.00 70.55 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -205.90 0.00 -2252.07 -318.80
T N2 APARTMENT 11-JAN-08:40 2317.42 0.00 0.00 0.00 70.60 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -205.36 0.00 -2251.15 -339.46
T S1 APARTMENT 07-MAR-03:00 903.89 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 0.00 0.00 -811.99 0.00 -357.35 -160.27
T S2 APARTMENT 07-MAR-03:00 904.86 0.00 0.00 0.00 189.67 6.49 229.56 0.00 0.00 0.00 0.00 0.00 -811.94 0.00 -357.35 -161.29
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 06-FEB-12:15 60814.94 0.00 0.00 0.00 3456.89 8844.29 32799.78 80961.48 0.00 0.00 0.00 0.00 0.00 0.00 -164533.70 -22343.68



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:36

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:36

Sec1.1A-General Information

Data
Weather File Phoenix Sky Harbor Intl Ap AZ USA TMY3 WMO#=722780
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 7836.48
Principal Heating Source Electricity


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.50
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
F2 SW APARTMENT 88.25 88.25 0.00 168.00
F2 NW APARTMENT 88.25 88.25 0.00 168.00
F2 SE APARTMENT 88.25 88.25 0.00 168.00
F2 NE APARTMENT 88.25 88.25 0.00 168.00
F2 N1 APARTMENT 88.25 88.25 0.00 168.00
F2 N2 APARTMENT 88.25 88.25 0.00 168.00
F2 S1 APARTMENT 88.25 88.25 0.00 168.00
F2 S2 APARTMENT 88.25 88.25 0.00 168.00
F3 SW APARTMENT 88.25 88.25 0.00 168.00
F3 NW APARTMENT 88.25 88.25 0.00 168.00
F3 SE APARTMENT 88.25 88.25 0.00 168.00
F3 NE APARTMENT 88.25 88.25 0.00 168.00
F3 N1 APARTMENT 88.25 88.25 0.00 168.00
F3 N2 APARTMENT 88.25 88.25 0.00 168.00
F3 S1 APARTMENT 88.25 88.25 0.00 168.00
F3 S2 APARTMENT 88.25 88.25 0.00 168.00
F4 SW APARTMENT 88.25 88.25 0.00 168.00
F4 NW APARTMENT 88.25 88.25 0.00 168.00
F4 SE APARTMENT 88.25 88.25 0.00 168.00
F4 NE APARTMENT 88.25 88.25 0.00 168.00
F4 N1 APARTMENT 88.25 88.25 0.00 168.00
F4 N2 APARTMENT 88.25 88.25 0.00 168.00
F4 S1 APARTMENT 88.25 88.25 0.00 168.00
F4 S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
F6 SW APARTMENT 88.25 88.25 0.00 168.00
F6 NW APARTMENT 88.25 88.25 0.00 168.00
F6 SE APARTMENT 88.25 88.25 0.00 168.00
F6 NE APARTMENT 88.25 88.25 0.00 168.00
F6 N1 APARTMENT 88.25 88.25 0.00 168.00
F6 N2 APARTMENT 88.25 88.25 0.00 168.00
F6 S1 APARTMENT 88.25 88.25 0.00 168.00
F6 S2 APARTMENT 88.25 88.25 0.00 168.00
F7 SW APARTMENT 88.25 88.25 0.00 168.00
F7 NW APARTMENT 88.25 88.25 0.00 168.00
F7 SE APARTMENT 88.25 88.25 0.00 168.00
F7 NE APARTMENT 88.25 88.25 0.00 168.00
F7 N1 APARTMENT 88.25 88.25 0.00 168.00
F7 N2 APARTMENT 88.25 88.25 0.00 168.00
F7 S1 APARTMENT 88.25 88.25 0.00 168.00
F7 S2 APARTMENT 88.25 88.25 0.00 168.00
F8 SW APARTMENT 88.25 88.25 0.00 168.00
F8 NW APARTMENT 88.25 88.25 0.00 168.00
F8 SE APARTMENT 88.25 88.25 0.00 168.00
F8 NE APARTMENT 88.25 88.25 0.00 168.00
F8 N1 APARTMENT 88.25 88.25 0.00 168.00
F8 N2 APARTMENT 88.25 88.25 0.00 168.00
F8 S1 APARTMENT 88.25 88.25 0.00 168.00
F8 S2 APARTMENT 88.25 88.25 0.00 168.00
F9 SW APARTMENT 88.25 88.25 0.00 168.00
F9 NW APARTMENT 88.25 88.25 0.00 168.00
F9 SE APARTMENT 88.25 88.25 0.00 168.00
F9 NE APARTMENT 88.25 88.25 0.00 168.00
F9 N1 APARTMENT 88.25 88.25 0.00 168.00
F9 N2 APARTMENT 88.25 88.25 0.00 168.00
F9 S1 APARTMENT 88.25 88.25 0.00 168.00
F9 S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
G CORRIDOR 77.66 0.00 77.66 0.00
F2 CORRIDOR 77.66 0.00 77.66 0.00
F3 CORRIDOR 77.66 0.00 77.66 0.00
F4 CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
F6 CORRIDOR 77.66 0.00 77.66 0.00
F7 CORRIDOR 77.66 0.00 77.66 0.00
F8 CORRIDOR 77.66 0.00 77.66 0.00
F9 CORRIDOR 77.66 0.00 77.66 0.00
T CORRIDOR 77.66 0.00 77.66 0.00
Totals 7836.48 7059.89 776.58  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 11.25
Number of hours cooling loads not met 362.25
Number of hours not met 373.50


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 296.56 13120.46 0.00 0.00 0.00 0.00
Exterior Lighting 162.75 0.00 0.00 0.00 0.00 0.00
Space Heating 8.14 0.00 7.22 57375.26 0.00 0.00
Space Cooling 1085.41 90743.74 0.00 0.00 0.00 0.00
Pumps 79.58 2563.97 0.00 0.00 0.00 0.00
Heat Rejection 44.12 3686.14 0.00 0.00 0.00 0.00
Fans-Interior 884.47 28046.48 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 0.00 0.00 855.99 73455.30 0.00 0.00
Receptacle Equipment 1137.32 57042.02 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 3734.52   863.21   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 1137.32 3734.52
Natural Gas 0.00 863.21
Additional 0.00 0.00
Total 1137.32 4597.73


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 37.84
Space Heating 1.04
Space Cooling 138.51
Fans-Interior 112.87
Service Water Heating 0.00
Receptacle Equipment 145.13
Miscellaneous 41.17
Subtotal 476.56


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 0.92
Service Water Heating 109.23
Miscellaneous -0.00
Subtotal 110.15


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 6.45
Space Heating 0.33
Space Cooling 23.61
Fans-Interior 19.24
Service Water Heating 18.62
Receptacle Equipment 24.74
Miscellaneous 7.02



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:36

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.330114
G NW APARTMENT DIRECT AIR 0.322766
OFFICE DIRECT AIR 0.433493
G NE APARTMENT DIRECT AIR 0.270374
G N1 APARTMENT DIRECT AIR 0.178087
G N2 APARTMENT DIRECT AIR 0.177018
G S1 APARTMENT DIRECT AIR 0.196515
G S2 APARTMENT DIRECT AIR 0.202501
F2 SW APARTMENT DIRECT AIR 0.381788
F2 NW APARTMENT DIRECT AIR 0.373066
F2 SE APARTMENT DIRECT AIR 0.360443
F2 NE APARTMENT DIRECT AIR 0.316151
F2 N1 APARTMENT DIRECT AIR 0.206184
F2 N2 APARTMENT DIRECT AIR 0.205352
F2 S1 APARTMENT DIRECT AIR 0.229405
F2 S2 APARTMENT DIRECT AIR 0.231322
F3 SW APARTMENT DIRECT AIR 0.384153
F3 NW APARTMENT DIRECT AIR 0.375631
F3 SE APARTMENT DIRECT AIR 0.343406
F3 NE APARTMENT DIRECT AIR 0.320165
F3 N1 APARTMENT DIRECT AIR 0.208948
F3 N2 APARTMENT DIRECT AIR 0.208134
F3 S1 APARTMENT DIRECT AIR 0.232068
F3 S2 APARTMENT DIRECT AIR 0.232831
F4 SW APARTMENT DIRECT AIR 0.387824
F4 NW APARTMENT DIRECT AIR 0.379237
F4 SE APARTMENT DIRECT AIR 0.345058
F4 NE APARTMENT DIRECT AIR 0.323803
F4 N1 APARTMENT DIRECT AIR 0.212169
F4 N2 APARTMENT DIRECT AIR 0.211366
F4 S1 APARTMENT DIRECT AIR 0.234932
F4 S2 APARTMENT DIRECT AIR 0.235528
M SW APARTMENT DIRECT AIR 0.393259
M NW APARTMENT DIRECT AIR 0.384648
M SE APARTMENT DIRECT AIR 0.350217
M NE APARTMENT DIRECT AIR 0.329208
M N1 APARTMENT DIRECT AIR 0.217126
M N2 APARTMENT DIRECT AIR 0.216333
M S1 APARTMENT DIRECT AIR 0.239569
M S2 APARTMENT DIRECT AIR 0.240139
F6 SW APARTMENT DIRECT AIR 0.392695
F6 NW APARTMENT DIRECT AIR 0.383964
F6 SE APARTMENT DIRECT AIR 0.349617
F6 NE APARTMENT DIRECT AIR 0.328548
F6 N1 APARTMENT DIRECT AIR 0.216199
F6 N2 APARTMENT DIRECT AIR 0.215418
F6 S1 APARTMENT DIRECT AIR 0.238500
F6 S2 APARTMENT DIRECT AIR 0.239043
F7 SW APARTMENT DIRECT AIR 0.393981
F7 NW APARTMENT DIRECT AIR 0.385222
F7 SE APARTMENT DIRECT AIR 0.350885
F7 NE APARTMENT DIRECT AIR 0.329912
F7 N1 APARTMENT DIRECT AIR 0.217185
F7 N2 APARTMENT DIRECT AIR 0.216433
F7 S1 APARTMENT DIRECT AIR 0.239306
F7 S2 APARTMENT DIRECT AIR 0.239816
F8 SW APARTMENT DIRECT AIR 0.396673
F8 NW APARTMENT DIRECT AIR 0.387908
F8 SE APARTMENT DIRECT AIR 0.353517
F8 NE APARTMENT DIRECT AIR 0.332616
F8 N1 APARTMENT DIRECT AIR 0.219624
F8 N2 APARTMENT DIRECT AIR 0.218879
F8 S1 APARTMENT DIRECT AIR 0.241510
F8 S2 APARTMENT DIRECT AIR 0.242000
F9 SW APARTMENT DIRECT AIR 0.410112
F9 NW APARTMENT DIRECT AIR 0.401639
F9 SE APARTMENT DIRECT AIR 0.362735
F9 NE APARTMENT DIRECT AIR 0.341442
F9 N1 APARTMENT DIRECT AIR 0.232090
F9 N2 APARTMENT DIRECT AIR 0.231339
F9 S1 APARTMENT DIRECT AIR 0.251511
F9 S2 APARTMENT DIRECT AIR 0.252057
T SW APARTMENT DIRECT AIR 0.498347
T NW APARTMENT DIRECT AIR 0.483516
T SE APARTMENT DIRECT AIR 0.446748
T NE APARTMENT DIRECT AIR 0.411296
T N1 APARTMENT DIRECT AIR 0.303663
T N2 APARTMENT DIRECT AIR 0.303533
T S1 APARTMENT DIRECT AIR 0.340092
T S2 APARTMENT DIRECT AIR 0.340618


Branch

Maximum Flow Rate [m3/s]
AIRLOOP G SW MAIN BRANCH 0.330114
AIRLOOP G NW MAIN BRANCH 0.322766
AIRLOOP OFFICE MAIN BRANCH 0.433493
AIRLOOP G NE MAIN BRANCH 0.270374
AIRLOOP G N1 MAIN BRANCH 0.178087
AIRLOOP G N2 MAIN BRANCH 0.177018
AIRLOOP G S1 MAIN BRANCH 0.196515
AIRLOOP G S2 MAIN BRANCH 0.202501
AIRLOOP F2 SW MAIN BRANCH 0.381788
AIRLOOP F2 NW MAIN BRANCH 0.373066
AIRLOOP F2 SE MAIN BRANCH 0.360443
AIRLOOP F2 NE MAIN BRANCH 0.316151
AIRLOOP F2 N1 MAIN BRANCH 0.206184
AIRLOOP F2 N2 MAIN BRANCH 0.205352
AIRLOOP F2 S1 MAIN BRANCH 0.229405
AIRLOOP F2 S2 MAIN BRANCH 0.231322
AIRLOOP F3 SW MAIN BRANCH 0.384153
AIRLOOP F3 NW MAIN BRANCH 0.375631
AIRLOOP F3 SE MAIN BRANCH 0.343406
AIRLOOP F3 NE MAIN BRANCH 0.320165
AIRLOOP F3 N1 MAIN BRANCH 0.208948
AIRLOOP F3 N2 MAIN BRANCH 0.208134
AIRLOOP F3 S1 MAIN BRANCH 0.232068
AIRLOOP F3 S2 MAIN BRANCH 0.232831
AIRLOOP F4 SW MAIN BRANCH 0.387824
AIRLOOP F4 NW MAIN BRANCH 0.379237
AIRLOOP F4 SE MAIN BRANCH 0.345058
AIRLOOP F4 NE MAIN BRANCH 0.323803
AIRLOOP F4 N1 MAIN BRANCH 0.212169
AIRLOOP F4 N2 MAIN BRANCH 0.211366
AIRLOOP F4 S1 MAIN BRANCH 0.234932
AIRLOOP F4 S2 MAIN BRANCH 0.235528
AIRLOOP M SW MAIN BRANCH 0.393259
AIRLOOP M NW MAIN BRANCH 0.384648
AIRLOOP M SE MAIN BRANCH 0.350217
AIRLOOP M NE MAIN BRANCH 0.329208
AIRLOOP M N1 MAIN BRANCH 0.217126
AIRLOOP M N2 MAIN BRANCH 0.216333
AIRLOOP M S1 MAIN BRANCH 0.239569
AIRLOOP M S2 MAIN BRANCH 0.240139
AIRLOOP F6 SW MAIN BRANCH 0.392695
AIRLOOP F6 NW MAIN BRANCH 0.383964
AIRLOOP F6 SE MAIN BRANCH 0.349617
AIRLOOP F6 NE MAIN BRANCH 0.328548
AIRLOOP F6 N1 MAIN BRANCH 0.216199
AIRLOOP F6 N2 MAIN BRANCH 0.215418
AIRLOOP F6 S1 MAIN BRANCH 0.238500
AIRLOOP F6 S2 MAIN BRANCH 0.239043
AIRLOOP F7 SW MAIN BRANCH 0.393981
AIRLOOP F7 NW MAIN BRANCH 0.385222
AIRLOOP F7 SE MAIN BRANCH 0.350885
AIRLOOP F7 NE MAIN BRANCH 0.329912
AIRLOOP F7 N1 MAIN BRANCH 0.217185
AIRLOOP F7 N2 MAIN BRANCH 0.216433
AIRLOOP F7 S1 MAIN BRANCH 0.239306
AIRLOOP F7 S2 MAIN BRANCH 0.239816
AIRLOOP F8 SW MAIN BRANCH 0.396673
AIRLOOP F8 NW MAIN BRANCH 0.387908
AIRLOOP F8 SE MAIN BRANCH 0.353517
AIRLOOP F8 NE MAIN BRANCH 0.332616
AIRLOOP F8 N1 MAIN BRANCH 0.219624
AIRLOOP F8 N2 MAIN BRANCH 0.218879
AIRLOOP F8 S1 MAIN BRANCH 0.241510
AIRLOOP F8 S2 MAIN BRANCH 0.242000
AIRLOOP F9 SW MAIN BRANCH 0.410112
AIRLOOP F9 NW MAIN BRANCH 0.401639
AIRLOOP F9 SE MAIN BRANCH 0.362735
AIRLOOP F9 NE MAIN BRANCH 0.341442
AIRLOOP F9 N1 MAIN BRANCH 0.232090
AIRLOOP F9 N2 MAIN BRANCH 0.231339
AIRLOOP F9 S1 MAIN BRANCH 0.251511
AIRLOOP F9 S2 MAIN BRANCH 0.252057
AIRLOOP T SW MAIN BRANCH 0.498347
AIRLOOP T NW MAIN BRANCH 0.483516
AIRLOOP T SE MAIN BRANCH 0.446748
AIRLOOP T NE MAIN BRANCH 0.411296
AIRLOOP T N1 MAIN BRANCH 0.303663
AIRLOOP T N2 MAIN BRANCH 0.303533
AIRLOOP T S1 MAIN BRANCH 0.340092
AIRLOOP T S2 MAIN BRANCH 0.340618


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
AIRLOOP G SW 0.330114
AIRLOOP G NW 0.322766
AIRLOOP OFFICE 0.433493
AIRLOOP G NE 0.270374
AIRLOOP G N1 0.178087
AIRLOOP G N2 0.177018
AIRLOOP G S1 0.196515
AIRLOOP G S2 0.202501
AIRLOOP F2 SW 0.381788
AIRLOOP F2 NW 0.373066
AIRLOOP F2 SE 0.360443
AIRLOOP F2 NE 0.316151
AIRLOOP F2 N1 0.206184
AIRLOOP F2 N2 0.205352
AIRLOOP F2 S1 0.229405
AIRLOOP F2 S2 0.231322
AIRLOOP F3 SW 0.384153
AIRLOOP F3 NW 0.375631
AIRLOOP F3 SE 0.343406
AIRLOOP F3 NE 0.320165
AIRLOOP F3 N1 0.208948
AIRLOOP F3 N2 0.208134
AIRLOOP F3 S1 0.232068
AIRLOOP F3 S2 0.232831
AIRLOOP F4 SW 0.387824
AIRLOOP F4 NW 0.379237
AIRLOOP F4 SE 0.345058
AIRLOOP F4 NE 0.323803
AIRLOOP F4 N1 0.212169
AIRLOOP F4 N2 0.211366
AIRLOOP F4 S1 0.234932
AIRLOOP F4 S2 0.235528
AIRLOOP M SW 0.393259
AIRLOOP M NW 0.384648
AIRLOOP M SE 0.350217
AIRLOOP M NE 0.329208
AIRLOOP M N1 0.217126
AIRLOOP M N2 0.216333
AIRLOOP M S1 0.239569
AIRLOOP M S2 0.240139
AIRLOOP F6 SW 0.392695
AIRLOOP F6 NW 0.383964
AIRLOOP F6 SE 0.349617
AIRLOOP F6 NE 0.328548
AIRLOOP F6 N1 0.216199
AIRLOOP F6 N2 0.215418
AIRLOOP F6 S1 0.238500
AIRLOOP F6 S2 0.239043
AIRLOOP F7 SW 0.393981
AIRLOOP F7 NW 0.385222
AIRLOOP F7 SE 0.350885
AIRLOOP F7 NE 0.329912
AIRLOOP F7 N1 0.217185
AIRLOOP F7 N2 0.216433
AIRLOOP F7 S1 0.239306
AIRLOOP F7 S2 0.239816
AIRLOOP F8 SW 0.396673
AIRLOOP F8 NW 0.387908
AIRLOOP F8 SE 0.353517
AIRLOOP F8 NE 0.332616
AIRLOOP F8 N1 0.219624
AIRLOOP F8 N2 0.218879
AIRLOOP F8 S1 0.241510
AIRLOOP F8 S2 0.242000
AIRLOOP F9 SW 0.410112
AIRLOOP F9 NW 0.401639
AIRLOOP F9 SE 0.362735
AIRLOOP F9 NE 0.341442
AIRLOOP F9 N1 0.232090
AIRLOOP F9 N2 0.231339
AIRLOOP F9 S1 0.251511
AIRLOOP F9 S2 0.252057
AIRLOOP T SW 0.498347
AIRLOOP T NW 0.483516
AIRLOOP T SE 0.446748
AIRLOOP T NE 0.411296
AIRLOOP T N1 0.303663
AIRLOOP T N2 0.303533
AIRLOOP T S1 0.340092
AIRLOOP T S2 0.340618


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
AIRLOOP G SW OA CONTROLLER 0.330114 0.025952
AIRLOOP G NW OA CONTROLLER 0.322766 0.025952
AIRLOOP OFFICE OA CONTROLLER 0.433493 0.038103
AIRLOOP G NE OA CONTROLLER 0.270374 0.025952
AIRLOOP G N1 OA CONTROLLER 0.178087 0.025952
AIRLOOP G N2 OA CONTROLLER 0.177018 0.025952
AIRLOOP G S1 OA CONTROLLER 0.196515 0.025952
AIRLOOP G S2 OA CONTROLLER 0.202501 0.025952
AIRLOOP F2 SW OA CONTROLLER 0.381788 0.025952
AIRLOOP F2 NW OA CONTROLLER 0.373066 0.025952
AIRLOOP F2 SE OA CONTROLLER 0.360443 0.025952
AIRLOOP F2 NE OA CONTROLLER 0.316151 0.025952
AIRLOOP F2 N1 OA CONTROLLER 0.206184 0.025952
AIRLOOP F2 N2 OA CONTROLLER 0.205352 0.025952
AIRLOOP F2 S1 OA CONTROLLER 0.229405 0.025952
AIRLOOP F2 S2 OA CONTROLLER 0.231322 0.025952
AIRLOOP F3 SW OA CONTROLLER 0.384153 0.025952
AIRLOOP F3 NW OA CONTROLLER 0.375631 0.025952
AIRLOOP F3 SE OA CONTROLLER 0.343406 0.025952
AIRLOOP F3 NE OA CONTROLLER 0.320165 0.025952
AIRLOOP F3 N1 OA CONTROLLER 0.208948 0.025952
AIRLOOP F3 N2 OA CONTROLLER 0.208134 0.025952
AIRLOOP F3 S1 OA CONTROLLER 0.232068 0.025952
AIRLOOP F3 S2 OA CONTROLLER 0.232831 0.025952
AIRLOOP F4 SW OA CONTROLLER 0.387824 0.025952
AIRLOOP F4 NW OA CONTROLLER 0.379237 0.025952
AIRLOOP F4 SE OA CONTROLLER 0.345058 0.025952
AIRLOOP F4 NE OA CONTROLLER 0.323803 0.025952
AIRLOOP F4 N1 OA CONTROLLER 0.212169 0.025952
AIRLOOP F4 N2 OA CONTROLLER 0.211366 0.025952
AIRLOOP F4 S1 OA CONTROLLER 0.234932 0.025952
AIRLOOP F4 S2 OA CONTROLLER 0.235528 0.025952
AIRLOOP M SW OA CONTROLLER 0.393259 0.025952
AIRLOOP M NW OA CONTROLLER 0.384648 0.025952
AIRLOOP M SE OA CONTROLLER 0.350217 0.025952
AIRLOOP M NE OA CONTROLLER 0.329208 0.025952
AIRLOOP M N1 OA CONTROLLER 0.217126 0.025952
AIRLOOP M N2 OA CONTROLLER 0.216333 0.025952
AIRLOOP M S1 OA CONTROLLER 0.239569 0.025952
AIRLOOP M S2 OA CONTROLLER 0.240139 0.025952
AIRLOOP F6 SW OA CONTROLLER 0.392695 0.025952
AIRLOOP F6 NW OA CONTROLLER 0.383964 0.025952
AIRLOOP F6 SE OA CONTROLLER 0.349617 0.025952
AIRLOOP F6 NE OA CONTROLLER 0.328548 0.025952
AIRLOOP F6 N1 OA CONTROLLER 0.216199 0.025952
AIRLOOP F6 N2 OA CONTROLLER 0.215418 0.025952
AIRLOOP F6 S1 OA CONTROLLER 0.238500 0.025952
AIRLOOP F6 S2 OA CONTROLLER 0.239043 0.025952
AIRLOOP F7 SW OA CONTROLLER 0.393981 0.025952
AIRLOOP F7 NW OA CONTROLLER 0.385222 0.025952
AIRLOOP F7 SE OA CONTROLLER 0.350885 0.025952
AIRLOOP F7 NE OA CONTROLLER 0.329912 0.025952
AIRLOOP F7 N1 OA CONTROLLER 0.217185 0.025952
AIRLOOP F7 N2 OA CONTROLLER 0.216433 0.025952
AIRLOOP F7 S1 OA CONTROLLER 0.239306 0.025952
AIRLOOP F7 S2 OA CONTROLLER 0.239816 0.025952
AIRLOOP F8 SW OA CONTROLLER 0.396673 0.025952
AIRLOOP F8 NW OA CONTROLLER 0.387908 0.025952
AIRLOOP F8 SE OA CONTROLLER 0.353517 0.025952
AIRLOOP F8 NE OA CONTROLLER 0.332616 0.025952
AIRLOOP F8 N1 OA CONTROLLER 0.219624 0.025952
AIRLOOP F8 N2 OA CONTROLLER 0.218879 0.025952
AIRLOOP F8 S1 OA CONTROLLER 0.241510 0.025952
AIRLOOP F8 S2 OA CONTROLLER 0.242000 0.025952
AIRLOOP F9 SW OA CONTROLLER 0.410112 0.025952
AIRLOOP F9 NW OA CONTROLLER 0.401639 0.025952
AIRLOOP F9 SE OA CONTROLLER 0.362735 0.025952
AIRLOOP F9 NE OA CONTROLLER 0.341442 0.025952
AIRLOOP F9 N1 OA CONTROLLER 0.232090 0.025952
AIRLOOP F9 N2 OA CONTROLLER 0.231339 0.025952
AIRLOOP F9 S1 OA CONTROLLER 0.251511 0.025952
AIRLOOP F9 S2 OA CONTROLLER 0.252057 0.025952
AIRLOOP T SW OA CONTROLLER 0.498347 0.025952
AIRLOOP T NW OA CONTROLLER 0.483516 0.025952
AIRLOOP T SE OA CONTROLLER 0.446748 0.025952
AIRLOOP T NE OA CONTROLLER 0.411296 0.025952
AIRLOOP T N1 OA CONTROLLER 0.303663 0.025952
AIRLOOP T N2 OA CONTROLLER 0.303533 0.025952
AIRLOOP T S1 OA CONTROLLER 0.340092 0.025952
AIRLOOP T S2 OA CONTROLLER 0.340618 0.025952


COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity [W] Rated Sensible Cooling Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP COOLING MODE AIRLOOP G SW 0.330114 4944.70 3594.30 0.000108
HEAT PUMP COOLING MODE AIRLOOP G NW 0.322766 4819.86 3505.73 0.000105
HEAT PUMP COOLING MODE AIRLOOP OFFICE 0.433493 6484.99 4721.09 0.000142
HEAT PUMP COOLING MODE AIRLOOP G NE 0.270374 4053.52 2947.75 0.000089
HEAT PUMP COOLING MODE AIRLOOP G N1 0.178087 2825.99 2004.98 0.000062
HEAT PUMP COOLING MODE AIRLOOP G N2 0.177018 2811.26 1993.91 0.000061
HEAT PUMP COOLING MODE AIRLOOP G S1 0.196515 3153.41 2230.14 0.000069
HEAT PUMP COOLING MODE AIRLOOP G S2 0.202501 3235.37 2292.13 0.000071
HEAT PUMP COOLING MODE AIRLOOP F2 SW 0.381788 5631.45 4118.89 0.000123
HEAT PUMP COOLING MODE AIRLOOP F2 NW 0.373066 5494.17 4018.91 0.000120
HEAT PUMP COOLING MODE AIRLOOP F2 SE 0.360443 5311.55 3887.58 0.000116
HEAT PUMP COOLING MODE AIRLOOP F2 NE 0.316151 4678.02 3420.19 0.000102
HEAT PUMP COOLING MODE AIRLOOP F2 N1 0.206184 3207.74 2296.47 0.000070
HEAT PUMP COOLING MODE AIRLOOP F2 N2 0.205352 3196.33 2287.88 0.000070
HEAT PUMP COOLING MODE AIRLOOP F2 S1 0.229405 3596.21 2568.45 0.000079
HEAT PUMP COOLING MODE AIRLOOP F2 S2 0.231322 3622.42 2588.24 0.000079
HEAT PUMP COOLING MODE AIRLOOP F3 SW 0.384153 5656.23 4141.34 0.000124
HEAT PUMP COOLING MODE AIRLOOP F3 NW 0.375631 5521.67 4043.39 0.000121
HEAT PUMP COOLING MODE AIRLOOP F3 SE 0.343406 5071.97 3711.05 0.000111
HEAT PUMP COOLING MODE AIRLOOP F3 NE 0.320165 4725.41 3459.59 0.000103
HEAT PUMP COOLING MODE AIRLOOP F3 N1 0.208948 3241.26 2323.92 0.000071
HEAT PUMP COOLING MODE AIRLOOP F3 N2 0.208134 3230.10 2315.52 0.000071
HEAT PUMP COOLING MODE AIRLOOP F3 S1 0.232068 3628.31 2594.88 0.000079
HEAT PUMP COOLING MODE AIRLOOP F3 S2 0.232831 3638.75 2602.76 0.000079
HEAT PUMP COOLING MODE AIRLOOP F4 SW 0.387824 5700.68 4177.63 0.000125
HEAT PUMP COOLING MODE AIRLOOP F4 NW 0.379237 5565.27 4079.01 0.000122
HEAT PUMP COOLING MODE AIRLOOP F4 SE 0.345058 5089.00 3726.67 0.000111
HEAT PUMP COOLING MODE AIRLOOP F4 NE 0.323803 4769.53 3495.59 0.000104
HEAT PUMP COOLING MODE AIRLOOP F4 N1 0.212169 3282.13 2356.35 0.000072
HEAT PUMP COOLING MODE AIRLOOP F4 N2 0.211366 3271.14 2348.07 0.000071
HEAT PUMP COOLING MODE AIRLOOP F4 S1 0.234932 3664.24 2623.66 0.000080
HEAT PUMP COOLING MODE AIRLOOP F4 S2 0.235528 3672.38 2629.80 0.000080
HEAT PUMP COOLING MODE AIRLOOP M SW 0.393259 5775.51 4234.89 0.000126
HEAT PUMP COOLING MODE AIRLOOP M NW 0.384648 5636.05 4135.48 0.000123
HEAT PUMP COOLING MODE AIRLOOP M SE 0.350217 5154.81 3778.50 0.000113
HEAT PUMP COOLING MODE AIRLOOP M NE 0.329208 4838.72 3549.95 0.000106
HEAT PUMP COOLING MODE AIRLOOP M N1 0.217126 3347.39 2406.82 0.000073
HEAT PUMP COOLING MODE AIRLOOP M N2 0.216333 3336.53 2398.65 0.000073
HEAT PUMP COOLING MODE AIRLOOP M S1 0.239569 3724.95 2670.84 0.000081
HEAT PUMP COOLING MODE AIRLOOP M S2 0.240139 3732.74 2676.72 0.000082
HEAT PUMP COOLING MODE AIRLOOP F6 SW 0.392695 5763.95 4228.17 0.000126
HEAT PUMP COOLING MODE AIRLOOP F6 NW 0.383964 5622.84 4127.52 0.000123
HEAT PUMP COOLING MODE AIRLOOP F6 SE 0.349617 5142.86 3771.43 0.000112
HEAT PUMP COOLING MODE AIRLOOP F6 NE 0.328548 4825.97 3542.27 0.000105
HEAT PUMP COOLING MODE AIRLOOP F6 N1 0.216199 3332.42 2396.71 0.000073
HEAT PUMP COOLING MODE AIRLOOP F6 N2 0.215418 3321.73 2388.66 0.000073
HEAT PUMP COOLING MODE AIRLOOP F6 S1 0.238500 3712.36 2661.02 0.000081
HEAT PUMP COOLING MODE AIRLOOP F6 S2 0.239043 3715.54 2664.88 0.000081
HEAT PUMP COOLING MODE AIRLOOP F7 SW 0.393981 5778.07 4240.53 0.000126
HEAT PUMP COOLING MODE AIRLOOP F7 NW 0.385222 5636.58 4139.60 0.000123
HEAT PUMP COOLING MODE AIRLOOP F7 SE 0.350885 5156.79 3783.62 0.000113
HEAT PUMP COOLING MODE AIRLOOP F7 NE 0.329912 4854.16 3561.09 0.000106
HEAT PUMP COOLING MODE AIRLOOP F7 N1 0.217185 3352.76 2410.75 0.000073
HEAT PUMP COOLING MODE AIRLOOP F7 N2 0.216433 3342.47 2402.99 0.000073
HEAT PUMP COOLING MODE AIRLOOP F7 S1 0.239306 3721.41 2668.85 0.000081
HEAT PUMP COOLING MODE AIRLOOP F7 S2 0.239816 3724.14 2672.37 0.000081
HEAT PUMP COOLING MODE AIRLOOP F8 SW 0.396673 5811.70 4267.40 0.000127
HEAT PUMP COOLING MODE AIRLOOP F8 NW 0.387908 5670.12 4166.39 0.000124
HEAT PUMP COOLING MODE AIRLOOP F8 SE 0.353517 5189.65 3809.90 0.000113
HEAT PUMP COOLING MODE AIRLOOP F8 NE 0.332616 4888.03 3588.11 0.000107
HEAT PUMP COOLING MODE AIRLOOP F8 N1 0.219624 3384.35 2435.45 0.000074
HEAT PUMP COOLING MODE AIRLOOP F8 N2 0.218879 3374.18 2427.78 0.000074
HEAT PUMP COOLING MODE AIRLOOP F8 S1 0.241510 3749.74 2691.16 0.000082
HEAT PUMP COOLING MODE AIRLOOP F8 S2 0.242000 3756.44 2696.21 0.000082
HEAT PUMP COOLING MODE AIRLOOP F9 SW 0.410112 5986.62 4401.83 0.000131
HEAT PUMP COOLING MODE AIRLOOP F9 NW 0.401639 5854.40 4306.46 0.000128
HEAT PUMP COOLING MODE AIRLOOP F9 SE 0.362735 5321.03 3907.51 0.000116
HEAT PUMP COOLING MODE AIRLOOP F9 NE 0.341442 5005.45 3677.95 0.000109
HEAT PUMP COOLING MODE AIRLOOP F9 N1 0.232090 3544.48 2559.13 0.000077
HEAT PUMP COOLING MODE AIRLOOP F9 N2 0.231339 3542.93 2555.77 0.000077
HEAT PUMP COOLING MODE AIRLOOP F9 S1 0.251511 3884.62 2793.86 0.000085
HEAT PUMP COOLING MODE AIRLOOP F9 S2 0.252057 3892.07 2799.47 0.000085
HEAT PUMP COOLING MODE AIRLOOP T SW 0.498347 7202.93 5313.14 0.000157
HEAT PUMP COOLING MODE AIRLOOP T NW 0.483516 6988.79 5155.84 0.000153
HEAT PUMP COOLING MODE AIRLOOP T SE 0.446748 6515.69 4791.43 0.000142
HEAT PUMP COOLING MODE AIRLOOP T NE 0.411296 5962.26 4396.91 0.000130
HEAT PUMP COOLING MODE AIRLOOP T N1 0.303663 4594.55 3330.19 0.000100
HEAT PUMP COOLING MODE AIRLOOP T N2 0.303533 4592.76 3328.85 0.000100
HEAT PUMP COOLING MODE AIRLOOP T S1 0.340092 5091.20 3704.44 0.000111
HEAT PUMP COOLING MODE AIRLOOP T S2 0.340618 5098.39 3709.85 0.000111


AirLoopHVAC:UnitaryHeatPump:WaterToAir

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Supplemental Heating Coil Nominal Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
AIRLOOP G SW DXAC HEAT PUMP 0.330114 0.330114 0.330114 0.330114 4944.70 4944.70 1814.94 1.00
AIRLOOP G NW DXAC HEAT PUMP 0.322766 0.322766 0.322766 0.322766 4819.86 4819.86 1816.25 1.00
AIRLOOP OFFICE DXAC HEAT PUMP 0.433493 0.433493 0.433493 0.433493 6484.99 6484.99 2375.90 1.00
AIRLOOP G NE DXAC HEAT PUMP 0.270374 0.270374 0.270374 0.270374 4053.52 4053.52 1811.69 1.00
AIRLOOP G N1 DXAC HEAT PUMP 0.178087 0.178087 0.178087 0.178087 2825.99 2825.99 1282.95 1.00
AIRLOOP G N2 DXAC HEAT PUMP 0.177018 0.177018 0.177018 0.177018 2811.26 2811.26 1282.88 1.00
AIRLOOP G S1 DXAC HEAT PUMP 0.196515 0.196515 0.196515 0.196515 3153.41 3153.41 1279.12 1.00
AIRLOOP G S2 DXAC HEAT PUMP 0.202501 0.202501 0.202501 0.202501 3235.37 3235.37 1285.25 1.00
AIRLOOP F2 SW DXAC HEAT PUMP 0.381788 0.381788 0.381788 0.381788 5631.45 5631.45 1769.67 1.00
AIRLOOP F2 NW DXAC HEAT PUMP 0.373066 0.373066 0.373066 0.373066 5494.17 5494.17 1770.54 1.00
AIRLOOP F2 SE DXAC HEAT PUMP 0.360443 0.360443 0.360443 0.360443 5311.55 5311.55 1784.02 1.00
AIRLOOP F2 NE DXAC HEAT PUMP 0.316151 0.316151 0.316151 0.316151 4678.02 4678.02 1765.38 1.00
AIRLOOP F2 N1 DXAC HEAT PUMP 0.206184 0.206184 0.206184 0.206184 3207.74 3207.74 1140.24 1.00
AIRLOOP F2 N2 DXAC HEAT PUMP 0.205352 0.205352 0.205352 0.205352 3196.33 3196.33 1140.15 1.00
AIRLOOP F2 S1 DXAC HEAT PUMP 0.229405 0.229405 0.229405 0.229405 3596.21 3596.21 1142.10 1.00
AIRLOOP F2 S2 DXAC HEAT PUMP 0.231322 0.231322 0.231322 0.231322 3622.42 3622.42 1143.42 1.00
AIRLOOP F3 SW DXAC HEAT PUMP 0.384153 0.384153 0.384153 0.384153 5656.23 5656.23 1753.45 1.00
AIRLOOP F3 NW DXAC HEAT PUMP 0.375631 0.375631 0.375631 0.375631 5521.67 5521.67 1754.10 1.00
AIRLOOP F3 SE DXAC HEAT PUMP 0.343406 0.343406 0.343406 0.343406 5071.97 5071.97 1750.98 1.00
AIRLOOP F3 NE DXAC HEAT PUMP 0.320165 0.320165 0.320165 0.320165 4725.41 4725.41 1749.20 1.00
AIRLOOP F3 N1 DXAC HEAT PUMP 0.208948 0.208948 0.208948 0.208948 3241.26 3241.26 1105.96 1.00
AIRLOOP F3 N2 DXAC HEAT PUMP 0.208134 0.208134 0.208134 0.208134 3230.10 3230.10 1105.87 1.00
AIRLOOP F3 S1 DXAC HEAT PUMP 0.232068 0.232068 0.232068 0.232068 3628.31 3628.31 1105.89 1.00
AIRLOOP F3 S2 DXAC HEAT PUMP 0.232831 0.232831 0.232831 0.232831 3638.75 3638.75 1106.06 1.00
AIRLOOP F4 SW DXAC HEAT PUMP 0.387824 0.387824 0.387824 0.387824 5700.68 5700.68 1768.71 1.00
AIRLOOP F4 NW DXAC HEAT PUMP 0.379237 0.379237 0.379237 0.379237 5565.27 5565.27 1769.66 1.00
AIRLOOP F4 SE DXAC HEAT PUMP 0.345058 0.345058 0.345058 0.345058 5089.00 5089.00 1764.45 1.00
AIRLOOP F4 NE DXAC HEAT PUMP 0.323803 0.323803 0.323803 0.323803 4769.53 4769.53 1765.11 1.00
AIRLOOP F4 N1 DXAC HEAT PUMP 0.212169 0.212169 0.212169 0.212169 3282.13 3282.13 1107.04 1.00
AIRLOOP F4 N2 DXAC HEAT PUMP 0.211366 0.211366 0.211366 0.211366 3271.14 3271.14 1106.96 1.00
AIRLOOP F4 S1 DXAC HEAT PUMP 0.234932 0.234932 0.234932 0.234932 3664.24 3664.24 1106.41 1.00
AIRLOOP F4 S2 DXAC HEAT PUMP 0.235528 0.235528 0.235528 0.235528 3672.38 3672.38 1106.36 1.00
AIRLOOP M SW DXAC HEAT PUMP 0.393259 0.393259 0.393259 0.393259 5775.51 5775.51 1768.36 1.00
AIRLOOP M NW DXAC HEAT PUMP 0.384648 0.384648 0.384648 0.384648 5636.05 5636.05 1768.46 1.00
AIRLOOP M SE DXAC HEAT PUMP 0.350217 0.350217 0.350217 0.350217 5154.81 5154.81 1764.22 1.00
AIRLOOP M NE DXAC HEAT PUMP 0.329208 0.329208 0.329208 0.329208 4838.72 4838.72 1764.28 1.00
AIRLOOP M N1 DXAC HEAT PUMP 0.217126 0.217126 0.217126 0.217126 3347.39 3347.39 1097.31 1.00
AIRLOOP M N2 DXAC HEAT PUMP 0.216333 0.216333 0.216333 0.216333 3336.53 3336.53 1097.23 1.00
AIRLOOP M S1 DXAC HEAT PUMP 0.239569 0.239569 0.239569 0.239569 3724.95 3724.95 1097.45 1.00
AIRLOOP M S2 DXAC HEAT PUMP 0.240139 0.240139 0.240139 0.240139 3732.74 3732.74 1097.38 1.00
AIRLOOP F6 SW DXAC HEAT PUMP 0.392695 0.392695 0.392695 0.392695 5763.95 5763.95 1825.51 1.00
AIRLOOP F6 NW DXAC HEAT PUMP 0.383964 0.383964 0.383964 0.383964 5622.84 5622.84 1826.44 1.00
AIRLOOP F6 SE DXAC HEAT PUMP 0.349617 0.349617 0.349617 0.349617 5142.86 5142.86 1821.69 1.00
AIRLOOP F6 NE DXAC HEAT PUMP 0.328548 0.328548 0.328548 0.328548 4825.97 4825.97 1822.62 1.00
AIRLOOP F6 N1 DXAC HEAT PUMP 0.216199 0.216199 0.216199 0.216199 3332.42 3332.42 1141.72 1.00
AIRLOOP F6 N2 DXAC HEAT PUMP 0.215418 0.215418 0.215418 0.215418 3321.73 3321.73 1141.65 1.00
AIRLOOP F6 S1 DXAC HEAT PUMP 0.238500 0.238500 0.238500 0.238500 3712.36 3712.36 1141.01 1.00
AIRLOOP F6 S2 DXAC HEAT PUMP 0.239043 0.239043 0.239043 0.239043 3715.54 3715.54 1140.95 1.00
AIRLOOP F7 SW DXAC HEAT PUMP 0.393981 0.393981 0.393981 0.393981 5778.07 5778.07 1861.44 1.00
AIRLOOP F7 NW DXAC HEAT PUMP 0.385222 0.385222 0.385222 0.385222 5636.58 5636.58 1862.16 1.00
AIRLOOP F7 SE DXAC HEAT PUMP 0.350885 0.350885 0.350885 0.350885 5156.79 5156.79 1857.98 1.00
AIRLOOP F7 NE DXAC HEAT PUMP 0.329912 0.329912 0.329912 0.329912 4854.16 4854.16 1858.69 1.00
AIRLOOP F7 N1 DXAC HEAT PUMP 0.217185 0.217185 0.217185 0.217185 3352.76 3352.76 1168.49 1.00
AIRLOOP F7 N2 DXAC HEAT PUMP 0.216433 0.216433 0.216433 0.216433 3342.47 3342.47 1168.43 1.00
AIRLOOP F7 S1 DXAC HEAT PUMP 0.239306 0.239306 0.239306 0.239306 3721.41 3721.41 1167.96 1.00
AIRLOOP F7 S2 DXAC HEAT PUMP 0.239816 0.239816 0.239816 0.239816 3724.14 3724.14 1167.90 1.00
AIRLOOP F8 SW DXAC HEAT PUMP 0.396673 0.396673 0.396673 0.396673 5811.70 5811.70 1900.21 1.00
AIRLOOP F8 NW DXAC HEAT PUMP 0.387908 0.387908 0.387908 0.387908 5670.12 5670.12 1900.58 1.00
AIRLOOP F8 SE DXAC HEAT PUMP 0.353517 0.353517 0.353517 0.353517 5189.65 5189.65 1897.08 1.00
AIRLOOP F8 NE DXAC HEAT PUMP 0.332616 0.332616 0.332616 0.332616 4888.03 4888.03 1897.46 1.00
AIRLOOP F8 N1 DXAC HEAT PUMP 0.219624 0.219624 0.219624 0.219624 3384.35 3384.35 1199.32 1.00
AIRLOOP F8 N2 DXAC HEAT PUMP 0.218879 0.218879 0.218879 0.218879 3374.18 3374.18 1199.26 1.00
AIRLOOP F8 S1 DXAC HEAT PUMP 0.241510 0.241510 0.241510 0.241510 3749.74 3749.74 1199.11 1.00
AIRLOOP F8 S2 DXAC HEAT PUMP 0.242000 0.242000 0.242000 0.242000 3756.44 3756.44 1199.05 1.00
AIRLOOP F9 SW DXAC HEAT PUMP 0.410112 0.410112 0.410112 0.410112 5986.62 5986.62 2022.47 1.00
AIRLOOP F9 NW DXAC HEAT PUMP 0.401639 0.401639 0.401639 0.401639 5854.40 5854.40 2021.10 1.00
AIRLOOP F9 SE DXAC HEAT PUMP 0.362735 0.362735 0.362735 0.362735 5321.03 5321.03 2019.65 1.00
AIRLOOP F9 NE DXAC HEAT PUMP 0.341442 0.341442 0.341442 0.341442 5005.45 5005.45 2018.28 1.00
AIRLOOP F9 N1 DXAC HEAT PUMP 0.232090 0.232090 0.232090 0.232090 3544.48 3544.48 1307.00 1.00
AIRLOOP F9 N2 DXAC HEAT PUMP 0.231339 0.231339 0.231339 0.231339 3542.93 3542.93 1306.95 1.00
AIRLOOP F9 S1 DXAC HEAT PUMP 0.251511 0.251511 0.251511 0.251511 3884.62 3884.62 1308.28 1.00
AIRLOOP F9 S2 DXAC HEAT PUMP 0.252057 0.252057 0.252057 0.252057 3892.07 3892.07 1308.23 1.00
AIRLOOP T SW DXAC HEAT PUMP 0.498347 0.498347 0.498347 0.498347 7202.93 7202.93 2441.16 1.00
AIRLOOP T NW DXAC HEAT PUMP 0.483516 0.483516 0.483516 0.483516 6988.79 6988.79 2443.61 1.00
AIRLOOP T SE DXAC HEAT PUMP 0.446748 0.446748 0.446748 0.446748 6515.69 6515.69 2438.78 1.00
AIRLOOP T NE DXAC HEAT PUMP 0.411296 0.411296 0.411296 0.411296 5962.26 5962.26 2441.23 1.00
AIRLOOP T N1 DXAC HEAT PUMP 0.303663 0.303663 0.303663 0.303663 4594.55 4594.55 1757.79 1.00
AIRLOOP T N2 DXAC HEAT PUMP 0.303533 0.303533 0.303533 0.303533 4592.76 4592.76 1757.74 1.00
AIRLOOP T S1 DXAC HEAT PUMP 0.340092 0.340092 0.340092 0.340092 5091.20 5091.20 1754.39 1.00
AIRLOOP T S2 DXAC HEAT PUMP 0.340618 0.340618 0.340618 0.340618 5098.39 5098.39 1754.35 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
AIRLOOP G SW SUPPLY FAN 0.330114
AIRLOOP G NW SUPPLY FAN 0.322766
AIRLOOP OFFICE SUPPLY FAN 0.433493
AIRLOOP G NE SUPPLY FAN 0.270374
AIRLOOP G N1 SUPPLY FAN 0.178087
AIRLOOP G N2 SUPPLY FAN 0.177018
AIRLOOP G S1 SUPPLY FAN 0.196515
AIRLOOP G S2 SUPPLY FAN 0.202501
AIRLOOP F2 SW SUPPLY FAN 0.381788
AIRLOOP F2 NW SUPPLY FAN 0.373066
AIRLOOP F2 SE SUPPLY FAN 0.360443
AIRLOOP F2 NE SUPPLY FAN 0.316151
AIRLOOP F2 N1 SUPPLY FAN 0.206184
AIRLOOP F2 N2 SUPPLY FAN 0.205352
AIRLOOP F2 S1 SUPPLY FAN 0.229405
AIRLOOP F2 S2 SUPPLY FAN 0.231322
AIRLOOP F3 SW SUPPLY FAN 0.384153
AIRLOOP F3 NW SUPPLY FAN 0.375631
AIRLOOP F3 SE SUPPLY FAN 0.343406
AIRLOOP F3 NE SUPPLY FAN 0.320165
AIRLOOP F3 N1 SUPPLY FAN 0.208948
AIRLOOP F3 N2 SUPPLY FAN 0.208134
AIRLOOP F3 S1 SUPPLY FAN 0.232068
AIRLOOP F3 S2 SUPPLY FAN 0.232831
AIRLOOP F4 SW SUPPLY FAN 0.387824
AIRLOOP F4 NW SUPPLY FAN 0.379237
AIRLOOP F4 SE SUPPLY FAN 0.345058
AIRLOOP F4 NE SUPPLY FAN 0.323803
AIRLOOP F4 N1 SUPPLY FAN 0.212169
AIRLOOP F4 N2 SUPPLY FAN 0.211366
AIRLOOP F4 S1 SUPPLY FAN 0.234932
AIRLOOP F4 S2 SUPPLY FAN 0.235528
AIRLOOP M SW SUPPLY FAN 0.393259
AIRLOOP M NW SUPPLY FAN 0.384648
AIRLOOP M SE SUPPLY FAN 0.350217
AIRLOOP M NE SUPPLY FAN 0.329208
AIRLOOP M N1 SUPPLY FAN 0.217126
AIRLOOP M N2 SUPPLY FAN 0.216333
AIRLOOP M S1 SUPPLY FAN 0.239569
AIRLOOP M S2 SUPPLY FAN 0.240139
AIRLOOP F6 SW SUPPLY FAN 0.392695
AIRLOOP F6 NW SUPPLY FAN 0.383964
AIRLOOP F6 SE SUPPLY FAN 0.349617
AIRLOOP F6 NE SUPPLY FAN 0.328548
AIRLOOP F6 N1 SUPPLY FAN 0.216199
AIRLOOP F6 N2 SUPPLY FAN 0.215418
AIRLOOP F6 S1 SUPPLY FAN 0.238500
AIRLOOP F6 S2 SUPPLY FAN 0.239043
AIRLOOP F7 SW SUPPLY FAN 0.393981
AIRLOOP F7 NW SUPPLY FAN 0.385222
AIRLOOP F7 SE SUPPLY FAN 0.350885
AIRLOOP F7 NE SUPPLY FAN 0.329912
AIRLOOP F7 N1 SUPPLY FAN 0.217185
AIRLOOP F7 N2 SUPPLY FAN 0.216433
AIRLOOP F7 S1 SUPPLY FAN 0.239306
AIRLOOP F7 S2 SUPPLY FAN 0.239816
AIRLOOP F8 SW SUPPLY FAN 0.396673
AIRLOOP F8 NW SUPPLY FAN 0.387908
AIRLOOP F8 SE SUPPLY FAN 0.353517
AIRLOOP F8 NE SUPPLY FAN 0.332616
AIRLOOP F8 N1 SUPPLY FAN 0.219624
AIRLOOP F8 N2 SUPPLY FAN 0.218879
AIRLOOP F8 S1 SUPPLY FAN 0.241510
AIRLOOP F8 S2 SUPPLY FAN 0.242000
AIRLOOP F9 SW SUPPLY FAN 0.410112
AIRLOOP F9 NW SUPPLY FAN 0.401639
AIRLOOP F9 SE SUPPLY FAN 0.362735
AIRLOOP F9 NE SUPPLY FAN 0.341442
AIRLOOP F9 N1 SUPPLY FAN 0.232090
AIRLOOP F9 N2 SUPPLY FAN 0.231339
AIRLOOP F9 S1 SUPPLY FAN 0.251511
AIRLOOP F9 S2 SUPPLY FAN 0.252057
AIRLOOP T SW SUPPLY FAN 0.498347
AIRLOOP T NW SUPPLY FAN 0.483516
AIRLOOP T SE SUPPLY FAN 0.446748
AIRLOOP T NE SUPPLY FAN 0.411296
AIRLOOP T N1 SUPPLY FAN 0.303663
AIRLOOP T N2 SUPPLY FAN 0.303533
AIRLOOP T S1 SUPPLY FAN 0.340092
AIRLOOP T S2 SUPPLY FAN 0.340618


COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Heating Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP HEATING MODE AIRLOOP G SW 0.330114 4944.70 0.000108
HEAT PUMP HEATING MODE AIRLOOP G NW 0.322766 4819.86 0.000105
HEAT PUMP HEATING MODE AIRLOOP OFFICE 0.433493 6484.99 0.000142
HEAT PUMP HEATING MODE AIRLOOP G NE 0.270374 4053.52 0.000089
HEAT PUMP HEATING MODE AIRLOOP G N1 0.178087 2825.99 0.000062
HEAT PUMP HEATING MODE AIRLOOP G N2 0.177018 2811.26 0.000061
HEAT PUMP HEATING MODE AIRLOOP G S1 0.196515 3153.41 0.000069
HEAT PUMP HEATING MODE AIRLOOP G S2 0.202501 3235.37 0.000071
HEAT PUMP HEATING MODE AIRLOOP F2 SW 0.381788 5631.45 0.000123
HEAT PUMP HEATING MODE AIRLOOP F2 NW 0.373066 5494.17 0.000120
HEAT PUMP HEATING MODE AIRLOOP F2 SE 0.360443 5311.55 0.000116
HEAT PUMP HEATING MODE AIRLOOP F2 NE 0.316151 4678.02 0.000102
HEAT PUMP HEATING MODE AIRLOOP F2 N1 0.206184 3207.74 0.000070
HEAT PUMP HEATING MODE AIRLOOP F2 N2 0.205352 3196.33 0.000070
HEAT PUMP HEATING MODE AIRLOOP F2 S1 0.229405 3596.21 0.000079
HEAT PUMP HEATING MODE AIRLOOP F2 S2 0.231322 3622.42 0.000079
HEAT PUMP HEATING MODE AIRLOOP F3 SW 0.384153 5656.23 0.000124
HEAT PUMP HEATING MODE AIRLOOP F3 NW 0.375631 5521.67 0.000121
HEAT PUMP HEATING MODE AIRLOOP F3 SE 0.343406 5071.97 0.000111
HEAT PUMP HEATING MODE AIRLOOP F3 NE 0.320165 4725.41 0.000103
HEAT PUMP HEATING MODE AIRLOOP F3 N1 0.208948 3241.26 0.000071
HEAT PUMP HEATING MODE AIRLOOP F3 N2 0.208134 3230.10 0.000071
HEAT PUMP HEATING MODE AIRLOOP F3 S1 0.232068 3628.31 0.000079
HEAT PUMP HEATING MODE AIRLOOP F3 S2 0.232831 3638.75 0.000079
HEAT PUMP HEATING MODE AIRLOOP F4 SW 0.387824 5700.68 0.000125
HEAT PUMP HEATING MODE AIRLOOP F4 NW 0.379237 5565.27 0.000122
HEAT PUMP HEATING MODE AIRLOOP F4 SE 0.345058 5089.00 0.000111
HEAT PUMP HEATING MODE AIRLOOP F4 NE 0.323803 4769.53 0.000104
HEAT PUMP HEATING MODE AIRLOOP F4 N1 0.212169 3282.13 0.000072
HEAT PUMP HEATING MODE AIRLOOP F4 N2 0.211366 3271.14 0.000071
HEAT PUMP HEATING MODE AIRLOOP F4 S1 0.234932 3664.24 0.000080
HEAT PUMP HEATING MODE AIRLOOP F4 S2 0.235528 3672.38 0.000080
HEAT PUMP HEATING MODE AIRLOOP M SW 0.393259 5775.51 0.000126
HEAT PUMP HEATING MODE AIRLOOP M NW 0.384648 5636.05 0.000123
HEAT PUMP HEATING MODE AIRLOOP M SE 0.350217 5154.81 0.000113
HEAT PUMP HEATING MODE AIRLOOP M NE 0.329208 4838.72 0.000106
HEAT PUMP HEATING MODE AIRLOOP M N1 0.217126 3347.39 0.000073
HEAT PUMP HEATING MODE AIRLOOP M N2 0.216333 3336.53 0.000073
HEAT PUMP HEATING MODE AIRLOOP M S1 0.239569 3724.95 0.000081
HEAT PUMP HEATING MODE AIRLOOP M S2 0.240139 3732.74 0.000082
HEAT PUMP HEATING MODE AIRLOOP F6 SW 0.392695 5763.95 0.000126
HEAT PUMP HEATING MODE AIRLOOP F6 NW 0.383964 5622.84 0.000123
HEAT PUMP HEATING MODE AIRLOOP F6 SE 0.349617 5142.86 0.000112
HEAT PUMP HEATING MODE AIRLOOP F6 NE 0.328548 4825.97 0.000105
HEAT PUMP HEATING MODE AIRLOOP F6 N1 0.216199 3332.42 0.000073
HEAT PUMP HEATING MODE AIRLOOP F6 N2 0.215418 3321.73 0.000073
HEAT PUMP HEATING MODE AIRLOOP F6 S1 0.238500 3712.36 0.000081
HEAT PUMP HEATING MODE AIRLOOP F6 S2 0.239043 3715.54 0.000081
HEAT PUMP HEATING MODE AIRLOOP F7 SW 0.393981 5778.07 0.000126
HEAT PUMP HEATING MODE AIRLOOP F7 NW 0.385222 5636.58 0.000123
HEAT PUMP HEATING MODE AIRLOOP F7 SE 0.350885 5156.79 0.000113
HEAT PUMP HEATING MODE AIRLOOP F7 NE 0.329912 4854.16 0.000106
HEAT PUMP HEATING MODE AIRLOOP F7 N1 0.217185 3352.76 0.000073
HEAT PUMP HEATING MODE AIRLOOP F7 N2 0.216433 3342.47 0.000073
HEAT PUMP HEATING MODE AIRLOOP F7 S1 0.239306 3721.41 0.000081
HEAT PUMP HEATING MODE AIRLOOP F7 S2 0.239816 3724.14 0.000081
HEAT PUMP HEATING MODE AIRLOOP F8 SW 0.396673 5811.70 0.000127
HEAT PUMP HEATING MODE AIRLOOP F8 NW 0.387908 5670.12 0.000124
HEAT PUMP HEATING MODE AIRLOOP F8 SE 0.353517 5189.65 0.000113
HEAT PUMP HEATING MODE AIRLOOP F8 NE 0.332616 4888.03 0.000107
HEAT PUMP HEATING MODE AIRLOOP F8 N1 0.219624 3384.35 0.000074
HEAT PUMP HEATING MODE AIRLOOP F8 N2 0.218879 3374.18 0.000074
HEAT PUMP HEATING MODE AIRLOOP F8 S1 0.241510 3749.74 0.000082
HEAT PUMP HEATING MODE AIRLOOP F8 S2 0.242000 3756.44 0.000082
HEAT PUMP HEATING MODE AIRLOOP F9 SW 0.410112 5986.62 0.000131
HEAT PUMP HEATING MODE AIRLOOP F9 NW 0.401639 5854.40 0.000128
HEAT PUMP HEATING MODE AIRLOOP F9 SE 0.362735 5321.03 0.000116
HEAT PUMP HEATING MODE AIRLOOP F9 NE 0.341442 5005.45 0.000109
HEAT PUMP HEATING MODE AIRLOOP F9 N1 0.232090 3544.48 0.000077
HEAT PUMP HEATING MODE AIRLOOP F9 N2 0.231339 3542.93 0.000077
HEAT PUMP HEATING MODE AIRLOOP F9 S1 0.251511 3884.62 0.000085
HEAT PUMP HEATING MODE AIRLOOP F9 S2 0.252057 3892.07 0.000085
HEAT PUMP HEATING MODE AIRLOOP T SW 0.498347 7202.93 0.000157
HEAT PUMP HEATING MODE AIRLOOP T NW 0.483516 6988.79 0.000153
HEAT PUMP HEATING MODE AIRLOOP T SE 0.446748 6515.69 0.000142
HEAT PUMP HEATING MODE AIRLOOP T NE 0.411296 5962.26 0.000130
HEAT PUMP HEATING MODE AIRLOOP T N1 0.303663 4594.55 0.000100
HEAT PUMP HEATING MODE AIRLOOP T N2 0.303533 4592.76 0.000100
HEAT PUMP HEATING MODE AIRLOOP T S1 0.340092 5091.20 0.000111
HEAT PUMP HEATING MODE AIRLOOP T S2 0.340618 5098.39 0.000111


Coil:Heating:Electric

Nominal Capacity [W]
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW 1814.94
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW 1816.25
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE 2375.90
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE 1811.69
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 1282.95
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 1282.88
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 1279.12
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 1285.25
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW 1769.67
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW 1770.54
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE 1784.02
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE 1765.38
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 1140.24
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 1140.15
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 1142.10
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 1143.42
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW 1753.45
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW 1754.10
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE 1750.98
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE 1749.20
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 1105.96
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 1105.87
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 1105.89
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 1106.06
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW 1768.71
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW 1769.66
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE 1764.45
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE 1765.11
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 1107.04
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 1106.96
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 1106.41
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 1106.36
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW 1768.36
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW 1768.46
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE 1764.22
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE 1764.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 1097.31
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 1097.23
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 1097.45
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 1097.38
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW 1825.51
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW 1826.44
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE 1821.69
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE 1822.62
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 1141.72
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 1141.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 1141.01
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 1140.95
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW 1861.44
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW 1862.16
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE 1857.98
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE 1858.69
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 1168.49
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 1168.43
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 1167.96
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 1167.90
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW 1900.21
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW 1900.58
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE 1897.08
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE 1897.46
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 1199.32
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 1199.26
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 1199.11
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 1199.05
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW 2022.47
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW 2021.10
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE 2019.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE 2018.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 1307.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 1306.95
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 1308.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 1308.23
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW 2441.16
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW 2443.61
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE 2438.78
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE 2441.23
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 1757.79
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 1757.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 1754.39
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 1754.35


PlantLoop

Maximum Loop Flow Rate [m3/s] Plant Loop Volume [m3]
SHWSYS1 0.000289 0.325214
SINGLE WATER PLANT LOOP 0.007913 8.90


Boiler:HotWater

Design Water Flow Rate [m3/s]
CENTRAL BOILER 0.007913


WaterHeater:Mixed

Use Side Design Flow Rate [m3/s]
SHWSYS1 WATER HEATER 0.000289


EvaporativeFluidCooler:SingleSpeed

Design Water Flow Rate [m3/s] Fan Power at Design Air Flow Rate [W] Design Air Flow Rate [m3/s] U-Factor Times Area Value at Design Air Flow Rate [W/C]
CENTRAL TOWER 0.007913 3820.03 10.46 11385.07


Pump:ConstantSpeed

Rated Flow Rate [m3/s] Rated Power Consumption [W]
SHWSYS1 PUMP 0.000289 36.93
PLANT CIRC PUMP 0.007913 2527.04



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:36

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW3 |
G WWALL SWA GWINDOW2 |
G NWALL NWA GWINDOW4 |
G WWALL NWA GWINDOW6 |
G SWALL SEA GWINDOW1 |
G EWALL SEA GWINDOW8 |
G NWALL NEA GWINDOW5 |
G EWALL NEA GWINDOW7 |
G NWALL N1A GWINDOW9 |
G NWALL N2A GWINDOW10 |
G SWALL S1A GWINDOW11 |
G SWALL S2A GWINDOW12 |
G WWALL C GWINDOW13 |
G EWALL C ENTRANCE DOOR |
F2 WWALL SWA F2WINDOW2 |
F2 SWALL SWA F2WINDOW3 |
F2 NWALL NWA F2WINDOW4 |
F2 WWALL NWA F2WINDOW6 |
F2 EWALL SEA F2WINDOW8 |
F2 SWALL SEA F2WINDOW1 |
F2 NWALL NEA F2WINDOW5 |
F2 EWALL NEA F2WINDOW7 |
F2 NWALL N1A F2WINDOW9 |
F2 NWALL N2A F2WINDOW10 |
F2 SWALL S1A F2WINDOW11 |
F2 SWALL S2A F2WINDOW12 |
F2 WWALL C F2WINDOW13 |
F2 EWALL C F2WINDOW14 |
F3 WWALL SWA F3WINDOW2 |
F3 SWALL SWA F3WINDOW3 |
F3 NWALL NWA F3WINDOW4 |
F3 WWALL NWA F3WINDOW6 |
F3 EWALL SEA F3WINDOW8 |
F3 SWALL SEA F3WINDOW1 |
F3 NWALL NEA F3WINDOW5 |
F3 EWALL NEA F3WINDOW7 |
F3 NWALL N1A F3WINDOW9 |
F3 NWALL N2A F3WINDOW10 |
F3 SWALL S1A F3WINDOW11 |
F3 SWALL S2A F3WINDOW12 |
F3 WWALL C F3WINDOW13 |
F3 EWALL C F3WINDOW14 |
F4 WWALL SWA F4WINDOW2 |
F4 SWALL SWA F4WINDOW3 |
F4 NWALL NWA F4WINDOW4 |
F4 WWALL NWA F4WINDOW6 |
F4 EWALL SEA F4WINDOW8 |
F4 SWALL SEA F4WINDOW1 |
F4 NWALL NEA F4WINDOW5 |
F4 EWALL NEA F4WINDOW7 |
F4 NWALL N1A F4WINDOW9 |
F4 NWALL N2A F4WINDOW10 |
F4 SWALL S1A F4WINDOW11 |
F4 SWALL S2A F4WINDOW12 |
F4 WWALL C F4WINDOW13 |
F4 EWALL C F4WINDOW14 |
M WWALL SWA MWINDOW2 |
M SWALL SWA MWINDOW3 |
M NWALL NWA MWINDOW4 |
M WWALL NWA MWINDOW6 |
M EWALL SEA MWINDOW8 |
M SWALL SEA MWINDOW1 |
M NWALL NEA MWINDOW5 |
M EWALL NEA MWINDOW7 |
M NWALL N1A MWINDOW9 |
M NWALL N2A MWINDOW10 |
M SWALL S1A MWINDOW11 |
M SWALL S2A MWINDOW12 |
M WWALL C MWINDOW13 |
M EWALL C MWINDOW14 |
F6 WWALL SWA F6WINDOW2 |
F6 SWALL SWA F6WINDOW3 |
F6 NWALL NWA F6WINDOW4 |
F6 WWALL NWA F6WINDOW6 |
F6 EWALL SEA F6WINDOW8 |
F6 SWALL SEA F6WINDOW1 |
F6 NWALL NEA F6WINDOW5 |
F6 EWALL NEA F6WINDOW7 |
F6 NWALL N1A F6WINDOW9 |
F6 NWALL N2A F6WINDOW10 |
F6 SWALL S1A F6WINDOW11 |
F6 SWALL S2A F6WINDOW12 |
F6 WWALL C F6WINDOW13 |
F6 EWALL C F6WINDOW14 |
F7 WWALL SWA F7WINDOW2 |
F7 SWALL SWA F7WINDOW3 |
F7 NWALL NWA F7WINDOW4 |
F7 WWALL NWA F7WINDOW6 |
F7 EWALL SEA F7WINDOW8 |
F7 SWALL SEA F7WINDOW1 |
F7 NWALL NEA F7WINDOW5 |
F7 EWALL NEA F7WINDOW7 |
F7 NWALL N1A F7WINDOW9 |
F7 NWALL N2A F7WINDOW10 |
F7 SWALL S1A F7WINDOW11 |
F7 SWALL S2A F7WINDOW12 |
F7 WWALL C F7WINDOW13 |
F7 EWALL C F7WINDOW14 |
F8 WWALL SWA F8WINDOW2 |
F8 SWALL SWA F8WINDOW3 |
F8 NWALL NWA F8WINDOW4 |
F8 WWALL NWA F8WINDOW6 |
F8 EWALL SEA F8WINDOW8 |
F8 SWALL SEA F8WINDOW1 |
F8 NWALL NEA F8WINDOW5 |
F8 EWALL NEA F8WINDOW7 |
F8 NWALL N1A F8WINDOW9 |
F8 NWALL N2A F8WINDOW10 |
F8 SWALL S1A F8WINDOW11 |
F8 SWALL S2A F8WINDOW12 |
F8 WWALL C F8WINDOW13 |
F8 EWALL C F8WINDOW14 |
F9 WWALL SWA F9WINDOW2 |
F9 SWALL SWA F9WINDOW3 |
F9 NWALL NWA F9WINDOW4 |
F9 WWALL NWA F9WINDOW6 |
F9 EWALL SEA F9WINDOW8 |
F9 SWALL SEA F9WINDOW1 |
F9 NWALL NEA F9WINDOW5 |
F9 EWALL NEA F9WINDOW7 |
F9 NWALL N1A F9WINDOW9 |
F9 NWALL N2A F9WINDOW10 |
F9 SWALL S1A F9WINDOW11 |
F9 SWALL S2A F9WINDOW12 |
F9 WWALL C F9WINDOW13 |
F9 EWALL C F9WINDOW14 |
T WWALL SWA TWINDOW2 |
T SWALL SWA TWINDOW3 |
T NWALL NWA TWINDOW4 |
T WWALL NWA TWINDOW6 |
T EWALL SEA TWINDOW8 |
T SWALL SEA TWINDOW1 |
T NWALL NEA TWINDOW5 |
T EWALL NEA TWINDOW7 |
T NWALL N1A TWINDOW9 |
T NWALL N2A TWINDOW10 |
T SWALL S1A TWINDOW11 |
T SWALL S2A TWINDOW12 |
T WWALL C TWINDOW13 |
T EWALL C TWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:36

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.14 13.01
February 23.43 15.66
March 23.70 17.34
April 24.07 23.65
May 24.31 27.29
June 24.40 33.99
July 24.41 35.56
August 24.42 33.82
September 24.42 30.39
October 24.32 24.81
November 23.98 17.95
December 23.12 11.71
     
Annual Sum or Average 23.98 23.80
Minimum of Months 23.12 11.71
Maximum of Months 24.42 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.32 13.01
February 22.90 15.66
March 23.41 17.34
April 24.01 23.65
May 24.31 27.29
June 24.41 33.99
July 24.42 35.56
August 24.41 33.82
September 24.40 30.39
October 24.25 24.81
November 23.53 17.95
December 22.21 11.71
     
Annual Sum or Average 23.72 23.80
Minimum of Months 22.21 11.71
Maximum of Months 24.42 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.40 13.01
February 23.72 15.66
March 23.96 17.34
April 24.24 23.65
May 24.39 27.29
June 24.40 33.99
July 24.40 35.56
August 24.40 33.82
September 24.40 30.39
October 24.36 24.81
November 24.15 17.95
December 23.30 11.71
     
Annual Sum or Average 24.09 23.80
Minimum of Months 23.30 11.71
Maximum of Months 24.40 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.22 13.01
February 22.87 15.66
March 23.41 17.34
April 24.04 23.65
May 24.32 27.29
June 24.40 33.99
July 24.41 35.56
August 24.40 33.82
September 24.40 30.39
October 24.27 24.81
November 23.56 17.95
December 22.11 11.71
     
Annual Sum or Average 23.70 23.80
Minimum of Months 22.11 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.10 13.01
February 22.70 15.66
March 23.19 17.34
April 23.93 23.65
May 24.28 27.29
June 24.40 33.99
July 24.42 35.56
August 24.41 33.82
September 24.40 30.39
October 24.21 24.81
November 23.37 17.95
December 22.01 11.71
     
Annual Sum or Average 23.62 23.80
Minimum of Months 22.01 11.71
Maximum of Months 24.42 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.10 13.01
February 22.69 15.66
March 23.19 17.34
April 23.93 23.65
May 24.28 27.29
June 24.40 33.99
July 24.42 35.56
August 24.41 33.82
September 24.40 30.39
October 24.21 24.81
November 23.37 17.95
December 22.00 11.71
     
Annual Sum or Average 23.62 23.80
Minimum of Months 22.00 11.71
Maximum of Months 24.42 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.20 13.01
February 23.44 15.66
March 23.66 17.34
April 24.05 23.65
May 24.29 27.29
June 24.40 33.99
July 24.40 35.56
August 24.43 33.82
September 24.45 30.39
October 24.33 24.81
November 24.01 17.95
December 23.19 11.71
     
Annual Sum or Average 23.99 23.80
Minimum of Months 23.19 11.71
Maximum of Months 24.45 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.24 13.01
February 23.48 15.66
March 23.69 17.34
April 24.06 23.65
May 24.29 27.29
June 24.40 33.99
July 24.40 35.56
August 24.42 33.82
September 24.45 30.39
October 24.33 24.81
November 24.03 17.95
December 23.23 11.71
     
Annual Sum or Average 24.00 23.80
Minimum of Months 23.23 11.71
Maximum of Months 24.45 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.44 13.01
February 21.52 15.66
March 22.33 17.34
April 24.77 23.65
May 26.10 27.29
June 28.78 33.99
July 29.31 35.56
August 28.78 33.82
September 27.77 30.39
October 25.36 24.81
November 22.71 17.95
December 20.00 11.71
     
Annual Sum or Average 24.84 23.80
Minimum of Months 20.00 11.71
Maximum of Months 29.31 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SW APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.82 13.01
February 23.92 15.66
March 24.08 17.34
April 24.25 23.65
May 24.37 27.29
June 24.40 33.99
July 24.41 35.56
August 24.41 33.82
September 24.41 30.39
October 24.39 24.81
November 24.33 17.95
December 23.74 11.71
     
Annual Sum or Average 24.21 23.80
Minimum of Months 23.74 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NW APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.82 13.01
February 23.37 15.66
March 23.86 17.34
April 24.18 23.65
May 24.37 27.29
June 24.41 33.99
July 24.41 35.56
August 24.40 33.82
September 24.40 30.39
October 24.35 24.81
November 24.05 17.95
December 22.63 11.71
     
Annual Sum or Average 23.94 23.80
Minimum of Months 22.63 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SE APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.86 13.01
February 23.98 15.66
March 24.11 17.34
April 24.29 23.65
May 24.38 27.29
June 24.40 33.99
July 24.40 35.56
August 24.40 33.82
September 24.40 30.39
October 24.39 24.81
November 24.34 17.95
December 23.78 11.71
     
Annual Sum or Average 24.23 23.80
Minimum of Months 23.78 11.71
Maximum of Months 24.40 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NE APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.67 13.01
February 23.31 15.66
March 23.85 17.34
April 24.21 23.65
May 24.37 27.29
June 24.40 33.99
July 24.41 35.56
August 24.40 33.82
September 24.40 30.39
October 24.36 24.81
November 24.06 17.95
December 22.49 11.71
     
Annual Sum or Average 23.91 23.80
Minimum of Months 22.49 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N1 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.62 13.01
February 23.21 15.66
March 23.74 17.34
April 24.15 23.65
May 24.36 27.29
June 24.41 33.99
July 24.42 35.56
August 24.40 33.82
September 24.40 30.39
October 24.35 24.81
November 23.98 17.95
December 22.44 11.71
     
Annual Sum or Average 23.87 23.80
Minimum of Months 22.44 11.71
Maximum of Months 24.42 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N2 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.61 13.01
February 23.21 15.66
March 23.74 17.34
April 24.15 23.65
May 24.36 27.29
June 24.41 33.99
July 24.42 35.56
August 24.40 33.82
September 24.40 30.39
October 24.35 24.81
November 23.98 17.95
December 22.43 11.71
     
Annual Sum or Average 23.87 23.80
Minimum of Months 22.43 11.71
Maximum of Months 24.42 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S1 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.96 13.01
February 24.00 15.66
March 24.08 17.34
April 24.25 23.65
May 24.36 27.29
June 24.40 33.99
July 24.40 35.56
August 24.42 33.82
September 24.45 30.39
October 24.43 24.81
November 24.35 17.95
December 23.91 11.71
     
Annual Sum or Average 24.25 23.80
Minimum of Months 23.91 11.71
Maximum of Months 24.45 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S2 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.97 13.01
February 24.01 15.66
March 24.09 17.34
April 24.26 23.65
May 24.36 27.29
June 24.40 33.99
July 24.40 35.56
August 24.42 33.82
September 24.45 30.39
October 24.43 24.81
November 24.35 17.95
December 23.92 11.71
     
Annual Sum or Average 24.25 23.80
Minimum of Months 23.92 11.71
Maximum of Months 24.45 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 CORRIDOR

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.05 13.01
February 24.56 15.66
March 25.13 17.34
April 25.93 23.65
May 26.45 27.29
June 27.21 33.99
July 27.35 35.56
August 27.20 33.82
September 26.93 30.39
October 26.26 24.81
November 25.39 17.95
December 23.85 11.71
     
Annual Sum or Average 25.87 23.80
Minimum of Months 23.85 11.71
Maximum of Months 27.35 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SW APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.93 13.01
February 23.99 15.66
March 24.11 17.34
April 24.26 23.65
May 24.37 27.29
June 24.40 33.99
July 24.41 35.56
August 24.41 33.82
September 24.41 30.39
October 24.40 24.81
November 24.35 17.95
December 23.84 11.71
     
Annual Sum or Average 24.24 23.80
Minimum of Months 23.84 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NW APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.97 13.01
February 23.47 15.66
March 23.93 17.34
April 24.20 23.65
May 24.37 27.29
June 24.41 33.99
July 24.41 35.56
August 24.40 33.82
September 24.40 30.39
October 24.37 24.81
November 24.14 17.95
December 22.76 11.71
     
Annual Sum or Average 23.99 23.80
Minimum of Months 22.76 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SE APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.88 13.01
February 23.98 15.66
March 24.11 17.34
April 24.29 23.65
May 24.38 27.29
June 24.40 33.99
July 24.40 35.56
August 24.41 33.82
September 24.41 30.39
October 24.39 24.81
November 24.35 17.95
December 23.79 11.71
     
Annual Sum or Average 24.23 23.80
Minimum of Months 23.79 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NE APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.82 13.01
February 23.40 15.66
March 23.91 17.34
April 24.23 23.65
May 24.38 27.29
June 24.40 33.99
July 24.41 35.56
August 24.40 33.82
September 24.40 30.39
October 24.37 24.81
November 24.14 17.95
December 22.61 11.71
     
Annual Sum or Average 23.96 23.80
Minimum of Months 22.61 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N1 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.84 13.01
February 23.37 15.66
March 23.85 17.34
April 24.18 23.65
May 24.36 27.29
June 24.41 33.99
July 24.42 35.56
August 24.40 33.82
September 24.40 30.39
October 24.36 24.81
November 24.10 17.95
December 22.64 11.71
     
Annual Sum or Average 23.95 23.80
Minimum of Months 22.64 11.71
Maximum of Months 24.42 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N2 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.82 13.01
February 23.36 15.66
March 23.85 17.34
April 24.19 23.65
May 24.36 27.29
June 24.41 33.99
July 24.43 35.56
August 24.40 33.82
September 24.40 30.39
October 24.36 24.81
November 24.10 17.95
December 22.62 11.71
     
Annual Sum or Average 23.94 23.80
Minimum of Months 22.62 11.71
Maximum of Months 24.43 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S1 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.09 13.01
February 24.10 15.66
March 24.14 17.34
April 24.28 23.65
May 24.36 27.29
June 24.40 33.99
July 24.40 35.56
August 24.42 33.82
September 24.44 30.39
October 24.44 24.81
November 24.37 17.95
December 24.05 11.71
     
Annual Sum or Average 24.29 23.80
Minimum of Months 24.05 11.71
Maximum of Months 24.44 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S2 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.09 13.01
February 24.10 15.66
March 24.14 17.34
April 24.28 23.65
May 24.36 27.29
June 24.40 33.99
July 24.40 35.56
August 24.42 33.82
September 24.44 30.39
October 24.44 24.81
November 24.37 17.95
December 24.05 11.71
     
Annual Sum or Average 24.29 23.80
Minimum of Months 24.05 11.71
Maximum of Months 24.44 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 CORRIDOR

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.53 13.01
February 24.99 15.66
March 25.51 17.34
April 26.16 23.65
May 26.60 27.29
June 27.15 33.99
July 27.26 35.56
August 27.12 33.82
September 26.91 30.39
October 26.44 24.81
November 25.77 17.95
December 24.33 11.71
     
Annual Sum or Average 26.07 23.80
Minimum of Months 24.33 11.71
Maximum of Months 27.26 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SW APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.95 13.01
February 24.00 15.66
March 24.13 17.34
April 24.26 23.65
May 24.37 27.29
June 24.40 33.99
July 24.41 35.56
August 24.41 33.82
September 24.41 30.39
October 24.39 24.81
November 24.36 17.95
December 23.85 11.71
     
Annual Sum or Average 24.25 23.80
Minimum of Months 23.85 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NW APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.04 13.01
February 23.52 15.66
March 23.95 17.34
April 24.20 23.65
May 24.37 27.29
June 24.41 33.99
July 24.42 35.56
August 24.40 33.82
September 24.40 30.39
October 24.37 24.81
November 24.16 17.95
December 22.82 11.71
     
Annual Sum or Average 24.01 23.80
Minimum of Months 22.82 11.71
Maximum of Months 24.42 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SE APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.89 13.01
February 23.97 15.66
March 24.11 17.34
April 24.28 23.65
May 24.38 27.29
June 24.40 33.99
July 24.40 35.56
August 24.41 33.82
September 24.41 30.39
October 24.39 24.81
November 24.35 17.95
December 23.79 11.71
     
Annual Sum or Average 24.23 23.80
Minimum of Months 23.79 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NE APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.88 13.01
February 23.45 15.66
March 23.93 17.34
April 24.23 23.65
May 24.38 27.29
June 24.40 33.99
July 24.41 35.56
August 24.40 33.82
September 24.40 30.39
October 24.37 24.81
November 24.17 17.95
December 22.67 11.71
     
Annual Sum or Average 23.98 23.80
Minimum of Months 22.67 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N1 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.94 13.01
February 23.44 15.66
March 23.89 17.34
April 24.20 23.65
May 24.36 27.29
June 24.41 33.99
July 24.43 35.56
August 24.41 33.82
September 24.40 30.39
October 24.36 24.81
November 24.15 17.95
December 22.74 11.71
     
Annual Sum or Average 23.98 23.80
Minimum of Months 22.74 11.71
Maximum of Months 24.43 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N2 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.93 13.01
February 23.43 15.66
March 23.89 17.34
April 24.20 23.65
May 24.36 27.29
June 24.41 33.99
July 24.43 35.56
August 24.41 33.82
September 24.40 30.39
October 24.36 24.81
November 24.15 17.95
December 22.72 11.71
     
Annual Sum or Average 23.97 23.80
Minimum of Months 22.72 11.71
Maximum of Months 24.43 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S1 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.12 13.01
February 24.12 15.66
March 24.16 17.34
April 24.28 23.65
May 24.36 27.29
June 24.40 33.99
July 24.40 35.56
August 24.42 33.82
September 24.44 30.39
October 24.44 24.81
November 24.38 17.95
December 24.08 11.71
     
Annual Sum or Average 24.30 23.80
Minimum of Months 24.08 11.71
Maximum of Months 24.44 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S2 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.12 13.01
February 24.12 15.66
March 24.16 17.34
April 24.28 23.65
May 24.36 27.29
June 24.40 33.99
July 24.40 35.56
August 24.42 33.82
September 24.44 30.39
October 24.44 24.81
November 24.38 17.95
December 24.07 11.71
     
Annual Sum or Average 24.30 23.80
Minimum of Months 24.07 11.71
Maximum of Months 24.44 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 CORRIDOR

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.71 13.01
February 25.15 15.66
March 25.66 17.34
April 26.27 23.65
May 26.70 27.29
June 27.21 33.99
July 27.32 35.56
August 27.18 33.82
September 26.97 30.39
October 26.53 24.81
November 25.91 17.95
December 24.51 11.71
     
Annual Sum or Average 26.18 23.80
Minimum of Months 24.51 11.71
Maximum of Months 27.32 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.95 13.01
February 23.99 15.66
March 24.12 17.34
April 24.26 23.65
May 24.37 27.29
June 24.40 33.99
July 24.41 35.56
August 24.41 33.82
September 24.41 30.39
October 24.39 24.81
November 24.36 17.95
December 23.85 11.71
     
Annual Sum or Average 24.24 23.80
Minimum of Months 23.85 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.05 13.01
February 23.53 15.66
March 23.96 17.34
April 24.19 23.65
May 24.37 27.29
June 24.41 33.99
July 24.42 35.56
August 24.40 33.82
September 24.40 30.39
October 24.37 24.81
November 24.17 17.95
December 22.84 11.71
     
Annual Sum or Average 24.01 23.80
Minimum of Months 22.84 11.71
Maximum of Months 24.42 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.88 13.01
February 23.97 15.66
March 24.11 17.34
April 24.28 23.65
May 24.38 27.29
June 24.40 33.99
July 24.40 35.56
August 24.40 33.82
September 24.41 30.39
October 24.39 24.81
November 24.35 17.95
December 23.79 11.71
     
Annual Sum or Average 24.23 23.80
Minimum of Months 23.79 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.90 13.01
February 23.46 15.66
March 23.94 17.34
April 24.22 23.65
May 24.38 27.29
June 24.40 33.99
July 24.41 35.56
August 24.40 33.82
September 24.40 30.39
October 24.37 24.81
November 24.18 17.95
December 22.69 11.71
     
Annual Sum or Average 23.98 23.80
Minimum of Months 22.69 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.99 13.01
February 23.47 15.66
March 23.91 17.34
April 24.19 23.65
May 24.36 27.29
June 24.41 33.99
July 24.43 35.56
August 24.41 33.82
September 24.40 30.39
October 24.37 24.81
November 24.16 17.95
December 22.78 11.71
     
Annual Sum or Average 23.99 23.80
Minimum of Months 22.78 11.71
Maximum of Months 24.43 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.97 13.01
February 23.46 15.66
March 23.90 17.34
April 24.20 23.65
May 24.36 27.29
June 24.41 33.99
July 24.43 35.56
August 24.41 33.82
September 24.40 30.39
October 24.37 24.81
November 24.16 17.95
December 22.77 11.71
     
Annual Sum or Average 23.99 23.80
Minimum of Months 22.77 11.71
Maximum of Months 24.43 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.13 13.01
February 24.13 15.66
March 24.16 17.34
April 24.28 23.65
May 24.36 27.29
June 24.40 33.99
July 24.40 35.56
August 24.42 33.82
September 24.44 30.39
October 24.43 24.81
November 24.38 17.95
December 24.09 11.71
     
Annual Sum or Average 24.30 23.80
Minimum of Months 24.09 11.71
Maximum of Months 24.44 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.13 13.01
February 24.12 15.66
March 24.16 17.34
April 24.28 23.65
May 24.36 27.29
June 24.40 33.99
July 24.40 35.56
August 24.42 33.82
September 24.44 30.39
October 24.43 24.81
November 24.38 17.95
December 24.08 11.71
     
Annual Sum or Average 24.30 23.80
Minimum of Months 24.08 11.71
Maximum of Months 24.44 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 25.29 13.01
February 25.71 15.66
March 26.21 17.34
April 26.79 23.65
May 27.22 27.29
June 27.72 33.99
July 27.83 35.56
August 27.69 33.82
September 27.49 30.39
October 27.06 24.81
November 26.47 17.95
December 25.09 11.71
     
Annual Sum or Average 26.72 23.80
Minimum of Months 25.09 11.71
Maximum of Months 27.83 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SW APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.89 13.01
February 23.95 15.66
March 24.10 17.34
April 24.23 23.65
May 24.37 27.29
June 24.40 33.99
July 24.41 35.56
August 24.41 33.82
September 24.41 30.39
October 24.39 24.81
November 24.35 17.95
December 23.79 11.71
     
Annual Sum or Average 24.23 23.80
Minimum of Months 23.79 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NW APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.96 13.01
February 23.46 15.66
March 23.92 17.34
April 24.17 23.65
May 24.37 27.29
June 24.41 33.99
July 24.42 35.56
August 24.40 33.82
September 24.40 30.39
October 24.36 24.81
November 24.14 17.95
December 22.75 11.71
     
Annual Sum or Average 23.98 23.80
Minimum of Months 22.75 11.71
Maximum of Months 24.42 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SE APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.82 13.01
February 23.92 15.66
March 24.08 17.34
April 24.26 23.65
May 24.37 27.29
June 24.40 33.99
July 24.40 35.56
August 24.40 33.82
September 24.41 30.39
October 24.39 24.81
November 24.34 17.95
December 23.73 11.71
     
Annual Sum or Average 24.21 23.80
Minimum of Months 23.73 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NE APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.80 13.01
February 23.39 15.66
March 23.90 17.34
April 24.20 23.65
May 24.37 27.29
June 24.40 33.99
July 24.41 35.56
August 24.40 33.82
September 24.40 30.39
October 24.37 24.81
November 24.15 17.95
December 22.60 11.71
     
Annual Sum or Average 23.95 23.80
Minimum of Months 22.60 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N1 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.88 13.01
February 23.40 15.66
March 23.86 17.34
April 24.17 23.65
May 24.36 27.29
June 24.41 33.99
July 24.43 35.56
August 24.41 33.82
September 24.40 30.39
October 24.36 24.81
November 24.13 17.95
December 22.69 11.71
     
Annual Sum or Average 23.96 23.80
Minimum of Months 22.69 11.71
Maximum of Months 24.43 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N2 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.87 13.01
February 23.39 15.66
March 23.86 17.34
April 24.17 23.65
May 24.36 27.29
June 24.41 33.99
July 24.43 35.56
August 24.41 33.82
September 24.40 30.39
October 24.36 24.81
November 24.13 17.95
December 22.67 11.71
     
Annual Sum or Average 23.95 23.80
Minimum of Months 22.67 11.71
Maximum of Months 24.43 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S1 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.08 13.01
February 24.08 15.66
March 24.13 17.34
April 24.26 23.65
May 24.36 27.29
June 24.40 33.99
July 24.40 35.56
August 24.41 33.82
September 24.43 30.39
October 24.42 24.81
November 24.37 17.95
December 24.04 11.71
     
Annual Sum or Average 24.28 23.80
Minimum of Months 24.04 11.71
Maximum of Months 24.43 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S2 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.08 13.01
February 24.08 15.66
March 24.13 17.34
April 24.26 23.65
May 24.36 27.29
June 24.40 33.99
July 24.40 35.56
August 24.41 33.82
September 24.43 30.39
October 24.43 24.81
November 24.37 17.95
December 24.04 11.71
     
Annual Sum or Average 24.28 23.80
Minimum of Months 24.04 11.71
Maximum of Months 24.43 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 CORRIDOR

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.66 13.01
February 25.10 15.66
March 25.62 17.34
April 26.23 23.65
May 26.68 27.29
June 27.21 33.99
July 27.32 35.56
August 27.17 33.82
September 26.96 30.39
October 26.52 24.81
November 25.89 17.95
December 24.46 11.71
     
Annual Sum or Average 26.16 23.80
Minimum of Months 24.46 11.71
Maximum of Months 27.32 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SW APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.84 13.01
February 23.92 15.66
March 24.08 17.34
April 24.22 23.65
May 24.36 27.29
June 24.40 33.99
July 24.41 35.56
August 24.41 33.82
September 24.41 30.39
October 24.39 24.81
November 24.34 17.95
December 23.75 11.71
     
Annual Sum or Average 24.21 23.80
Minimum of Months 23.75 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NW APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.89 13.01
February 23.42 15.66
March 23.89 17.34
April 24.15 23.65
May 24.36 27.29
June 24.41 33.99
July 24.42 35.56
August 24.40 33.82
September 24.40 30.39
October 24.35 24.81
November 24.11 17.95
December 22.68 11.71
     
Annual Sum or Average 23.96 23.80
Minimum of Months 22.68 11.71
Maximum of Months 24.42 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SE APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.77 13.01
February 23.89 15.66
March 24.06 17.34
April 24.24 23.65
May 24.37 27.29
June 24.40 33.99
July 24.40 35.56
August 24.40 33.82
September 24.41 30.39
October 24.39 24.81
November 24.33 17.95
December 23.68 11.71
     
Annual Sum or Average 24.20 23.80
Minimum of Months 23.68 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NE APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.74 13.01
February 23.34 15.66
March 23.87 17.34
April 24.18 23.65
May 24.37 27.29
June 24.40 33.99
July 24.41 35.56
August 24.40 33.82
September 24.40 30.39
October 24.36 24.81
November 24.12 17.95
December 22.53 11.71
     
Annual Sum or Average 23.93 23.80
Minimum of Months 22.53 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N1 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.81 13.01
February 23.35 15.66
March 23.83 17.34
April 24.15 23.65
May 24.35 27.29
June 24.41 33.99
July 24.43 35.56
August 24.41 33.82
September 24.40 30.39
October 24.35 24.81
November 24.10 17.95
December 22.61 11.71
     
Annual Sum or Average 23.94 23.80
Minimum of Months 22.61 11.71
Maximum of Months 24.43 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N2 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.80 13.01
February 23.34 15.66
March 23.83 17.34
April 24.15 23.65
May 24.35 27.29
June 24.41 33.99
July 24.43 35.56
August 24.40 33.82
September 24.40 30.39
October 24.35 24.81
November 24.10 17.95
December 22.60 11.71
     
Annual Sum or Average 23.93 23.80
Minimum of Months 22.60 11.71
Maximum of Months 24.43 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S1 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.05 13.01
February 24.05 15.66
March 24.12 17.34
April 24.24 23.65
May 24.35 27.29
June 24.40 33.99
July 24.40 35.56
August 24.41 33.82
September 24.43 30.39
October 24.42 24.81
November 24.37 17.95
December 24.00 11.71
     
Annual Sum or Average 24.27 23.80
Minimum of Months 24.00 11.71
Maximum of Months 24.43 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S2 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.05 13.01
February 24.05 15.66
March 24.11 17.34
April 24.24 23.65
May 24.35 27.29
June 24.40 33.99
July 24.40 35.56
August 24.41 33.82
September 24.43 30.39
October 24.42 24.81
November 24.37 17.95
December 24.00 11.71
     
Annual Sum or Average 24.27 23.80
Minimum of Months 24.00 11.71
Maximum of Months 24.43 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 CORRIDOR

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.51 13.01
February 24.97 15.66
March 25.51 17.34
April 26.13 23.65
May 26.61 27.29
June 27.15 33.99
July 27.27 35.56
August 27.11 33.82
September 26.90 30.39
October 26.44 24.81
November 25.79 17.95
December 24.31 11.71
     
Annual Sum or Average 26.06 23.80
Minimum of Months 24.31 11.71
Maximum of Months 27.27 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SW APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.80 13.01
February 23.89 15.66
March 24.07 17.34
April 24.20 23.65
May 24.36 27.29
June 24.40 33.99
July 24.41 35.56
August 24.41 33.82
September 24.41 30.39
October 24.38 24.81
November 24.34 17.95
December 23.70 11.71
     
Annual Sum or Average 24.20 23.80
Minimum of Months 23.70 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NW APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.83 13.01
February 23.38 15.66
March 23.87 17.34
April 24.13 23.65
May 24.36 27.29
June 24.41 33.99
July 24.42 35.56
August 24.40 33.82
September 24.40 30.39
October 24.35 24.81
November 24.09 17.95
December 22.63 11.71
     
Annual Sum or Average 23.94 23.80
Minimum of Months 22.63 11.71
Maximum of Months 24.42 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SE APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.72 13.01
February 23.86 15.66
March 24.05 17.34
April 24.23 23.65
May 24.37 27.29
June 24.40 33.99
July 24.40 35.56
August 24.40 33.82
September 24.41 30.39
October 24.38 24.81
November 24.32 17.95
December 23.64 11.71
     
Annual Sum or Average 24.18 23.80
Minimum of Months 23.64 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NE APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.68 13.01
February 23.31 15.66
March 23.85 17.34
April 24.16 23.65
May 24.37 27.29
June 24.40 33.99
July 24.41 35.56
August 24.40 33.82
September 24.40 30.39
October 24.36 24.81
November 24.10 17.95
December 22.48 11.71
     
Annual Sum or Average 23.91 23.80
Minimum of Months 22.48 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N1 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.75 13.01
February 23.31 15.66
March 23.81 17.34
April 24.13 23.65
May 24.35 27.29
June 24.41 33.99
July 24.43 35.56
August 24.40 33.82
September 24.40 30.39
October 24.35 24.81
November 24.08 17.95
December 22.56 11.71
     
Annual Sum or Average 23.92 23.80
Minimum of Months 22.56 11.71
Maximum of Months 24.43 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N2 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.74 13.01
February 23.31 15.66
March 23.80 17.34
April 24.13 23.65
May 24.35 27.29
June 24.41 33.99
July 24.43 35.56
August 24.40 33.82
September 24.40 30.39
October 24.35 24.81
November 24.08 17.95
December 22.54 11.71
     
Annual Sum or Average 23.91 23.80
Minimum of Months 22.54 11.71
Maximum of Months 24.43 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S1 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.01 13.01
February 24.02 15.66
March 24.10 17.34
April 24.23 23.65
May 24.35 27.29
June 24.40 33.99
July 24.40 35.56
August 24.41 33.82
September 24.43 30.39
October 24.41 24.81
November 24.36 17.95
December 23.97 11.71
     
Annual Sum or Average 24.26 23.80
Minimum of Months 23.97 11.71
Maximum of Months 24.43 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S2 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.01 13.01
February 24.02 15.66
March 24.10 17.34
April 24.23 23.65
May 24.35 27.29
June 24.40 33.99
July 24.40 35.56
August 24.41 33.82
September 24.43 30.39
October 24.41 24.81
November 24.36 17.95
December 23.96 11.71
     
Annual Sum or Average 24.26 23.80
Minimum of Months 23.96 11.71
Maximum of Months 24.43 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 CORRIDOR

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.42 13.01
February 24.90 15.66
March 25.47 17.34
April 26.11 23.65
May 26.61 27.29
June 27.17 33.99
July 27.29 35.56
August 27.13 33.82
September 26.91 30.39
October 26.43 24.81
November 25.75 17.95
December 24.22 11.71
     
Annual Sum or Average 26.04 23.80
Minimum of Months 24.22 11.71
Maximum of Months 27.29 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SW APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.72 13.01
February 23.85 15.66
March 24.05 17.34
April 24.19 23.65
May 24.36 27.29
June 24.40 33.99
July 24.41 35.56
August 24.41 33.82
September 24.41 30.39
October 24.38 24.81
November 24.33 17.95
December 23.63 11.71
     
Annual Sum or Average 24.18 23.80
Minimum of Months 23.63 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NW APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.78 13.01
February 23.36 15.66
March 23.85 17.34
April 24.12 23.65
May 24.36 27.29
June 24.41 33.99
July 24.42 35.56
August 24.40 33.82
September 24.40 30.39
October 24.35 24.81
November 24.06 17.95
December 22.58 11.71
     
Annual Sum or Average 23.92 23.80
Minimum of Months 22.58 11.71
Maximum of Months 24.42 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SE APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.64 13.01
February 23.83 15.66
March 24.03 17.34
April 24.21 23.65
May 24.37 27.29
June 24.40 33.99
July 24.41 35.56
August 24.40 33.82
September 24.40 30.39
October 24.38 24.81
November 24.31 17.95
December 23.57 11.71
     
Annual Sum or Average 24.16 23.80
Minimum of Months 23.57 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NE APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.62 13.01
February 23.29 15.66
March 23.83 17.34
April 24.15 23.65
May 24.37 27.29
June 24.40 33.99
July 24.42 35.56
August 24.40 33.82
September 24.40 30.39
October 24.36 24.81
November 24.07 17.95
December 22.44 11.71
     
Annual Sum or Average 23.89 23.80
Minimum of Months 22.44 11.71
Maximum of Months 24.42 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N1 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.69 13.01
February 23.30 15.66
March 23.79 17.34
April 24.12 23.65
May 24.35 27.29
June 24.41 33.99
July 24.43 35.56
August 24.40 33.82
September 24.40 30.39
October 24.35 24.81
November 24.05 17.95
December 22.50 11.71
     
Annual Sum or Average 23.90 23.80
Minimum of Months 22.50 11.71
Maximum of Months 24.43 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N2 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.68 13.01
February 23.29 15.66
March 23.78 17.34
April 24.12 23.65
May 24.35 27.29
June 24.41 33.99
July 24.43 35.56
August 24.40 33.82
September 24.40 30.39
October 24.35 24.81
November 24.05 17.95
December 22.49 11.71
     
Annual Sum or Average 23.90 23.80
Minimum of Months 22.49 11.71
Maximum of Months 24.43 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S1 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.93 13.01
February 23.98 15.66
March 24.07 17.34
April 24.21 23.65
May 24.35 27.29
June 24.40 33.99
July 24.40 35.56
August 24.41 33.82
September 24.42 30.39
October 24.40 24.81
November 24.35 17.95
December 23.89 11.71
     
Annual Sum or Average 24.24 23.80
Minimum of Months 23.89 11.71
Maximum of Months 24.42 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S2 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.93 13.01
February 23.97 15.66
March 24.07 17.34
April 24.21 23.65
May 24.35 27.29
June 24.40 33.99
July 24.40 35.56
August 24.41 33.82
September 24.42 30.39
October 24.40 24.81
November 24.35 17.95
December 23.88 11.71
     
Annual Sum or Average 24.24 23.80
Minimum of Months 23.88 11.71
Maximum of Months 24.42 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 CORRIDOR

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.29 13.01
February 24.85 15.66
March 25.46 17.34
April 26.17 23.65
May 26.72 27.29
June 27.35 33.99
July 27.48 35.56
August 27.30 33.82
September 27.04 30.39
October 26.49 24.81
November 25.71 17.95
December 24.09 11.71
     
Annual Sum or Average 26.08 23.80
Minimum of Months 24.09 11.71
Maximum of Months 27.48 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.35 13.01
February 23.64 15.66
March 23.90 17.34
April 24.11 23.65
May 24.33 27.29
June 24.40 33.99
July 24.41 35.56
August 24.40 33.82
September 24.40 30.39
October 24.34 24.81
November 24.13 17.95
December 23.29 11.71
     
Annual Sum or Average 24.06 23.80
Minimum of Months 23.29 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.72 13.01
February 23.29 15.66
March 23.72 17.34
April 24.07 23.65
May 24.34 27.29
June 24.41 33.99
July 24.41 35.56
August 24.40 33.82
September 24.40 30.39
October 24.29 24.81
November 23.84 17.95
December 22.61 11.71
     
Annual Sum or Average 23.88 23.80
Minimum of Months 22.61 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.29 13.01
February 23.61 15.66
March 23.88 17.34
April 24.15 23.65
May 24.35 27.29
June 24.40 33.99
July 24.40 35.56
August 24.40 33.82
September 24.40 30.39
October 24.34 24.81
November 24.10 17.95
December 23.25 11.71
     
Annual Sum or Average 24.05 23.80
Minimum of Months 23.25 11.71
Maximum of Months 24.40 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.59 13.01
February 23.25 15.66
March 23.71 17.34
April 24.10 23.65
May 24.34 27.29
June 24.40 33.99
July 24.41 35.56
August 24.40 33.82
September 24.40 30.39
October 24.30 24.81
November 23.85 17.95
December 22.49 11.71
     
Annual Sum or Average 23.85 23.80
Minimum of Months 22.49 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.61 13.01
February 23.25 15.66
March 23.69 17.34
April 24.07 23.65
May 24.33 27.29
June 24.40 33.99
July 24.41 35.56
August 24.40 33.82
September 24.40 30.39
October 24.29 24.81
November 23.84 17.95
December 22.50 11.71
     
Annual Sum or Average 23.85 23.80
Minimum of Months 22.50 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.60 13.01
February 23.25 15.66
March 23.69 17.34
April 24.07 23.65
May 24.33 27.29
June 24.40 33.99
July 24.41 35.56
August 24.40 33.82
September 24.40 30.39
October 24.29 24.81
November 23.84 17.95
December 22.50 11.71
     
Annual Sum or Average 23.85 23.80
Minimum of Months 22.50 11.71
Maximum of Months 24.41 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.52 13.01
February 23.76 15.66
March 23.95 17.34
April 24.15 23.65
May 24.33 27.29
June 24.40 33.99
July 24.40 35.56
August 24.40 33.82
September 24.42 30.39
October 24.36 24.81
November 24.20 17.95
December 23.47 11.71
     
Annual Sum or Average 24.11 23.80
Minimum of Months 23.47 11.71
Maximum of Months 24.42 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.52 13.01
February 23.76 15.66
March 23.95 17.34
April 24.15 23.65
May 24.33 27.29
June 24.40 33.99
July 24.40 35.56
August 24.40 33.82
September 24.42 30.39
October 24.36 24.81
November 24.20 17.95
December 23.47 11.71
     
Annual Sum or Average 24.11 23.80
Minimum of Months 23.47 11.71
Maximum of Months 24.42 35.56



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2015-09-09 19:11:36

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.48 13.01
February 25.27 15.66
March 25.94 17.34
April 26.96 23.65
May 27.68 27.29
June 28.57 33.99
July 28.75 35.56
August 28.48 33.82
September 28.08 30.39
October 27.21 24.81
November 26.07 17.95
December 24.27 11.71
     
Annual Sum or Average 26.82 23.80
Minimum of Months 24.27 11.71
Maximum of Months 28.75 35.56



Table of Contents

Report: COMPONENTS OF PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2015-09-09 19:11:36

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY {AT MAX/MIN} [W] HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W]
January 0.241196E+12 145937.726 08-JAN-17:15 11327.174 57042.023 28046.477 0.000 43241.134 0.000 2563.967 1729.309 0.000 0.000 0.000 0.000 0.000 0.000 0.000
February 0.232823E+12 167347.617 28-FEB-17:15 11327.174 57142.088 28046.477 0.000 63981.842 0.000 2563.967 2290.872 0.000 0.000 0.000 0.000 0.000 0.000 0.000
March 0.266976E+12 166622.549 16-MAR-17:15 13120.457 57042.023 28046.477 0.000 61747.903 0.000 2563.967 2113.909 0.000 0.000 0.000 0.000 0.000 0.000 0.000
April 0.298852E+12 181388.948 26-APR-16:15 11327.174 57142.088 28046.477 0.000 77565.281 0.000 2563.967 2748.764 0.000 0.000 0.000 0.000 0.000 0.000 0.000
May 0.334733E+12 191999.658 14-MAY-17:15 13120.457 57042.023 28046.477 0.000 86442.776 0.000 2563.967 2796.146 0.000 0.000 0.000 0.000 0.000 0.000 0.000
June 0.373347E+12 193779.397 12-JUN-17:15 13120.457 57042.023 28046.477 0.000 88075.672 0.000 2563.967 2942.989 0.000 0.000 0.000 0.000 0.000 0.000 0.000
July 0.407442E+12 197190.806 07-JUL-17:00 13120.457 57042.023 28046.477 0.000 90743.738 0.000 2563.967 3686.135 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 0.394567E+12 197154.594 01-AUG-17:00 13120.457 57042.023 28046.477 0.000 90573.634 0.000 2563.967 3820.027 0.000 0.000 0.000 0.000 0.000 0.000 0.000
September 0.356808E+12 189759.302 10-SEP-16:15 11327.174 57042.023 28046.477 0.000 85879.778 0.000 2563.967 2912.240 0.000 0.000 0.000 0.000 0.000 0.000 0.000
October 0.324937E+12 186341.197 02-OCT-16:15 11327.174 57142.088 28046.477 0.000 82347.714 0.000 2563.967 2918.580 0.000 0.000 0.000 0.000 0.000 0.000 0.000
November 0.261721E+12 164735.079 05-NOV-16:15 11327.174 57042.023 28046.477 0.000 61624.792 0.000 2563.967 2143.004 0.000 0.000 0.000 0.000 0.000 0.000 0.000
December 0.241119E+12 132881.932 02-DEC-17:30 11327.174 57042.023 28046.477 0.000 20639.427 10364.000 2563.967 911.052 0.000 0.000 0.000 0.000 0.000 0.000 0.000
                                     
Annual Sum or Average 0.373452E+13                     0.000 0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.232823E+12 132881.932   11327.174 57042.023 28046.477 0.000 20639.427 0.000 2563.967 911.052 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.407442E+12 197190.806   13120.457 57142.088 28046.477 0.000 90743.738 10364.000 2563.967 3820.027 0.000 0.000 0.000 0.000 0.000 0.000 0.000



Table of Contents

Report: COMPONENTS OF PEAK GAS DEMAND

For: Meter

Timestamp: 2015-09-09 19:11:36

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC [Invalid/Undefined] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT {AT MAX/MIN} [W] WATERSYSTEMS:GAS {AT MAX/MIN} [W] WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] HEATING:GAS {AT MAX/MIN} [W]
January 0.889117E+11 117165.608 31-JAN-07:15 0.000 0.000 0.000 117165.608 73617.433 73617.433 43548.175
February 0.821011E+11 130830.560 10-FEB-07:15 0.000 0.000 0.000 130830.560 73455.301 73455.301 57375.259
March 0.844187E+11 98778.075 07-MAR-06:30 0.000 0.000 0.000 98778.075 69944.268 69944.268 28833.807
April 0.722719E+11 71382.941 01-APR-06:00 0.000 0.000 0.000 71382.941 71382.941 71382.941 0.000
May 0.665056E+11 68986.286 02-MAY-06:00 0.000 0.000 0.000 68986.286 68986.286 68986.286 0.000
June 0.580560E+11 66867.905 03-JUN-06:00 0.000 0.000 0.000 66867.905 66867.905 66867.905 0.000
July 0.569233E+11 65634.106 05-JUL-06:45 0.000 0.000 0.000 65634.106 65634.106 65634.106 0.000
August 0.581141E+11 66040.223 26-AUG-06:30 0.000 0.000 0.000 66040.223 66040.223 66040.223 0.000
September 0.612736E+11 67884.178 28-SEP-06:45 0.000 0.000 0.000 67884.178 67884.178 67884.178 0.000
October 0.709808E+11 70383.196 31-OCT-06:00 0.000 0.000 0.000 70383.196 70383.196 70383.196 0.000
November 0.765793E+11 72619.736 30-NOV-07:00 0.000 0.000 0.000 72619.736 72619.736 72619.736 0.000
December 0.870762E+11 96266.332 16-DEC-06:45 0.000 0.000 0.000 96266.332 71686.849 71686.849 24579.482
                     
Annual Sum or Average 0.863212E+12     0.000 0.000 0.000        
Minimum of Months 0.569233E+11 65634.106   0.000 0.000 0.000 65634.106 65634.106 65634.106 0.000
Maximum of Months 0.889117E+11 130830.560   0.000 0.000 0.000 130830.560 73617.433 73617.433 57375.259