Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:59
Tabular Output Report in Format: HTML
Building: High-Rise Apartment
Environment: Chicago Ohare Intl Ap IL USA TMY3 WMO#=725300
Simulation Timestamp: 2015-09-09 19:00:30
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 5654.51 | 721.56 | 800.93 |
Net Site Energy | 5654.51 | 721.56 | 800.93 |
Total Source Energy | 12631.01 | 1611.82 | 1789.12 |
Net Source Energy | 12631.01 | 1611.82 | 1789.12 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 7836.48 |
Net Conditioned Building Area | 7059.89 |
Unconditioned Building Area | 776.58 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 361.26 | 1355.40 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 382.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 296.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 162.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1137.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 74.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 17.81 | 0.00 | 0.00 | 0.00 | 0.00 | 1086.63 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 1177.88 | 0.00 | 0.00 | 0.00 | 4778.51 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 3121.23 | 2533.28 | 0.00 | 0.00 | 0.00 | 5865.14 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Boiler | 0.00 | 1355.40 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Other | 361.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 382.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 242.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 54.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 162.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 1137.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 74.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 17.81 | 0.00 | 0.00 | 0.00 | 0.00 | 1086.63 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 1177.88 | 0.00 | 0.00 | 0.00 | 0.00 |
sub cat | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4778.51 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 65.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 210.84 | 358.83 | 0.00 | 0.00 | 0.00 | 0.83 |
Other | 161.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 442.11 | 358.83 | 0.00 | 0.00 | 0.00 | 0.83 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 58.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 189.94 | 323.27 | 0.00 | 0.00 | 0.00 | 0.75 |
Other | 145.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 398.29 | 323.27 | 0.00 | 0.00 | 0.00 | 0.75 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 3121.23 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 3121.23 | 100.00 |
Total On-Site and Utility Electric Sources | 3121.23 | 100.00 |
Total Electricity End Uses | 3121.23 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 5865.14 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 5865.14 | 100.00 |
Total Water End Uses | 5865.14 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 95.50 |
Time Setpoint Not Met During Occupied Cooling | 99.50 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 3332.75 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |COMPONENTS OF PEAK ELECTRICAL DEMAND
| Meter |COMPONENTS OF PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:59 |
RunPeriod | Chicago Ohare Intl Ap IL USA TMY3 WMO#=725300 |
Weather File | Chicago Ohare Intl Ap IL USA TMY3 WMO#=725300 |
Latitude [deg] | 41.98 |
Longitude [deg] | -87.9 |
Elevation [m] | 201.00 |
Time Zone | -6.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 3855.02 | 1411.96 | 515.55 | 1411.96 | 515.55 |
Window Opening Area [m2] | 1150.39 | 423.59 | 152.73 | 423.59 | 150.48 |
Window-Wall Ratio [%] | 29.84 | 30.00 | 29.62 | 30.00 | 29.19 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 3752.84 | 1411.96 | 464.46 | 1411.96 | 464.46 |
Window Opening Area [m2] | 1125.85 | 423.59 | 139.34 | 423.59 | 139.34 |
Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 29.5362 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 4.47 | 6.7128 | 0.0000 | |
F2 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F3 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F4 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
M SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 13.4255 | 0.0000 | |
F6 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F7 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F8 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F9 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
T SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 264.3872 | |
Total | 7836.48 | 23884.04 | 3855.02 | 1150.39 | 4.3335 | 39.48 | 8.6291 | |||
Conditioned Total | 7059.89 | 21517.16 | 3752.84 | 1125.85 | 3.9979 | 35.57 | 6.6700 | |||
Unconditioned Total | 776.58 | 2366.87 | 102.18 | 24.54 | 7.3840 | 26.4387 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 26-JAN-22:00 | 27-JAN-07:30 | - | - | - | 17-JUL-17:15 |
Heating | 143682.79 | 359120.69 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 9277.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 10364.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 37445.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 20693.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 2423.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 83123.27 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 225073.24 | 442243.97 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | Boiler | 0.00 | 359120.69 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 7711.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 1566.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 10364.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 37445.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 20693.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 2423.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 83123.27 | 0.00 | 0.00 | 0.00 | 0.00 |
sub cat | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 1144.11 | 1469.26 | 0.00 | 0.00 | 0.00 |
Cooling | 1210.49 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 939.20 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 515.22 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 3601.91 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 2066.78 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 236.27 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 56.42 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 1276.82 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 9884.93 | 2746.08 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 162.06 | 208.11 | 0.00 | 0.00 | 0.00 |
Cooling | 171.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 133.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 72.98 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 510.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 292.75 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 33.47 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 7.99 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 180.86 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1400.15 | 388.97 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 162.06 | 208.11 | 0.00 | 0.00 | 0.00 |
Cooling | 171.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 133.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 72.98 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 510.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 292.75 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 33.47 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 7.99 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 180.86 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1400.15 | 388.97 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | -20.00 | 0.00 | -20.00 | Wetbulb [C] | 4.90 | 270.00 |
CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 33.30 | 10.50 | 23.70 | Wetbulb [C] | 5.20 | 230.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 270.00 | 180.00 | |
F2 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F2 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F2 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F2 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F2 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F2 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F3 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F3 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F3 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F3 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F3 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F3 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F4 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F4 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F4 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F4 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F4 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F4 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F6 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F6 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F6 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F6 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F6 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F6 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F7 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F7 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F7 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F7 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F7 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F7 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F8 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F8 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F8 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F8 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F8 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F8 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F9 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F9 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F9 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F9 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F9 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F9 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.30 | 0.269 | 0.283 | 77.66 | 0.00 | 0.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
GWINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | G WWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_0.48_SHGC_0.40 | 3.36 | 0.00 | 0.00 | 3.36 | 3.36 | 2.653 | 0.426 | 0.308 | No | G EWALL C | 90.00 | 90.00 | E | ||
F2WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F2 WWALL SWA | 270.00 | 90.00 | W | ||
F2WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 SWALL SWA | 180.00 | 90.00 | S | ||
F2WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 NWALL NWA | 0.00 | 90.00 | N | ||
F2WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F2 WWALL NWA | 270.00 | 90.00 | W | ||
F2WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F2 EWALL SEA | 90.00 | 90.00 | E | ||
F2WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 SWALL SEA | 180.00 | 90.00 | S | ||
F2WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 NWALL NEA | 0.00 | 90.00 | N | ||
F2WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F2 EWALL NEA | 90.00 | 90.00 | E | ||
F2WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 NWALL N1A | 0.00 | 90.00 | N | ||
F2WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 NWALL N2A | 0.00 | 90.00 | N | ||
F2WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 SWALL S1A | 180.00 | 90.00 | S | ||
F2WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 SWALL S2A | 180.00 | 90.00 | S | ||
F2WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F2 WWALL C | 270.00 | 90.00 | W | ||
F2WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F2 EWALL C | 90.00 | 90.00 | E | ||
F3WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F3 WWALL SWA | 270.00 | 90.00 | W | ||
F3WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 SWALL SWA | 180.00 | 90.00 | S | ||
F3WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 NWALL NWA | 0.00 | 90.00 | N | ||
F3WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F3 WWALL NWA | 270.00 | 90.00 | W | ||
F3WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F3 EWALL SEA | 90.00 | 90.00 | E | ||
F3WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 SWALL SEA | 180.00 | 90.00 | S | ||
F3WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 NWALL NEA | 0.00 | 90.00 | N | ||
F3WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F3 EWALL NEA | 90.00 | 90.00 | E | ||
F3WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 NWALL N1A | 0.00 | 90.00 | N | ||
F3WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 NWALL N2A | 0.00 | 90.00 | N | ||
F3WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 SWALL S1A | 180.00 | 90.00 | S | ||
F3WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 SWALL S2A | 180.00 | 90.00 | S | ||
F3WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F3 WWALL C | 270.00 | 90.00 | W | ||
F3WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F3 EWALL C | 90.00 | 90.00 | E | ||
F4WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F4 WWALL SWA | 270.00 | 90.00 | W | ||
F4WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 SWALL SWA | 180.00 | 90.00 | S | ||
F4WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 NWALL NWA | 0.00 | 90.00 | N | ||
F4WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F4 WWALL NWA | 270.00 | 90.00 | W | ||
F4WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F4 EWALL SEA | 90.00 | 90.00 | E | ||
F4WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 SWALL SEA | 180.00 | 90.00 | S | ||
F4WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 NWALL NEA | 0.00 | 90.00 | N | ||
F4WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F4 EWALL NEA | 90.00 | 90.00 | E | ||
F4WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 NWALL N1A | 0.00 | 90.00 | N | ||
F4WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 NWALL N2A | 0.00 | 90.00 | N | ||
F4WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 SWALL S1A | 180.00 | 90.00 | S | ||
F4WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 SWALL S2A | 180.00 | 90.00 | S | ||
F4WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F4 WWALL C | 270.00 | 90.00 | W | ||
F4WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F4 EWALL C | 90.00 | 90.00 | E | ||
MWINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | M WWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | M EWALL C | 90.00 | 90.00 | E | ||
F6WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F6 WWALL SWA | 270.00 | 90.00 | W | ||
F6WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 SWALL SWA | 180.00 | 90.00 | S | ||
F6WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 NWALL NWA | 0.00 | 90.00 | N | ||
F6WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F6 WWALL NWA | 270.00 | 90.00 | W | ||
F6WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F6 EWALL SEA | 90.00 | 90.00 | E | ||
F6WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 SWALL SEA | 180.00 | 90.00 | S | ||
F6WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 NWALL NEA | 0.00 | 90.00 | N | ||
F6WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F6 EWALL NEA | 90.00 | 90.00 | E | ||
F6WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 NWALL N1A | 0.00 | 90.00 | N | ||
F6WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 NWALL N2A | 0.00 | 90.00 | N | ||
F6WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 SWALL S1A | 180.00 | 90.00 | S | ||
F6WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 SWALL S2A | 180.00 | 90.00 | S | ||
F6WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F6 WWALL C | 270.00 | 90.00 | W | ||
F6WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F6 EWALL C | 90.00 | 90.00 | E | ||
F7WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F7 WWALL SWA | 270.00 | 90.00 | W | ||
F7WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 SWALL SWA | 180.00 | 90.00 | S | ||
F7WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 NWALL NWA | 0.00 | 90.00 | N | ||
F7WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F7 WWALL NWA | 270.00 | 90.00 | W | ||
F7WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F7 EWALL SEA | 90.00 | 90.00 | E | ||
F7WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 SWALL SEA | 180.00 | 90.00 | S | ||
F7WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 NWALL NEA | 0.00 | 90.00 | N | ||
F7WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F7 EWALL NEA | 90.00 | 90.00 | E | ||
F7WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 NWALL N1A | 0.00 | 90.00 | N | ||
F7WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 NWALL N2A | 0.00 | 90.00 | N | ||
F7WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 SWALL S1A | 180.00 | 90.00 | S | ||
F7WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 SWALL S2A | 180.00 | 90.00 | S | ||
F7WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F7 WWALL C | 270.00 | 90.00 | W | ||
F7WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F7 EWALL C | 90.00 | 90.00 | E | ||
F8WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F8 WWALL SWA | 270.00 | 90.00 | W | ||
F8WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 SWALL SWA | 180.00 | 90.00 | S | ||
F8WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 NWALL NWA | 0.00 | 90.00 | N | ||
F8WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F8 WWALL NWA | 270.00 | 90.00 | W | ||
F8WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F8 EWALL SEA | 90.00 | 90.00 | E | ||
F8WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 SWALL SEA | 180.00 | 90.00 | S | ||
F8WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 NWALL NEA | 0.00 | 90.00 | N | ||
F8WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F8 EWALL NEA | 90.00 | 90.00 | E | ||
F8WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 NWALL N1A | 0.00 | 90.00 | N | ||
F8WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 NWALL N2A | 0.00 | 90.00 | N | ||
F8WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 SWALL S1A | 180.00 | 90.00 | S | ||
F8WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 SWALL S2A | 180.00 | 90.00 | S | ||
F8WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F8 WWALL C | 270.00 | 90.00 | W | ||
F8WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F8 EWALL C | 90.00 | 90.00 | E | ||
F9WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F9 WWALL SWA | 270.00 | 90.00 | W | ||
F9WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 SWALL SWA | 180.00 | 90.00 | S | ||
F9WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 NWALL NWA | 0.00 | 90.00 | N | ||
F9WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F9 WWALL NWA | 270.00 | 90.00 | W | ||
F9WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F9 EWALL SEA | 90.00 | 90.00 | E | ||
F9WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 SWALL SEA | 180.00 | 90.00 | S | ||
F9WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 NWALL NEA | 0.00 | 90.00 | N | ||
F9WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F9 EWALL NEA | 90.00 | 90.00 | E | ||
F9WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 NWALL N1A | 0.00 | 90.00 | N | ||
F9WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 NWALL N2A | 0.00 | 90.00 | N | ||
F9WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 SWALL S1A | 180.00 | 90.00 | S | ||
F9WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 SWALL S2A | 180.00 | 90.00 | S | ||
F9WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F9 WWALL C | 270.00 | 90.00 | W | ||
F9WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F9 EWALL C | 90.00 | 90.00 | E | ||
TWINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | T WWALL C | 270.00 | 90.00 | W | ||
TWINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | T EWALL C | 90.00 | 90.00 | E | ||
Total or Average | 1150.39 | 2.653 | 0.426 | 0.308 | ||||||||||||
North Total or Average | 423.59 | 2.653 | 0.426 | 0.308 | ||||||||||||
Non-North Total or Average | 726.80 | 2.653 | 0.426 | 0.308 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
GWINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
GWINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
GWINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
GWINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
F2WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
F2WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
F2WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
F2WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
F2WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
F2WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
F3WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
F3WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
F3WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
F3WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
F3WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
F3WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
F4WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
F4WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
F4WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
F4WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
F4WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
F4WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
MWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
MWINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
MWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
MWINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
MWINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
F6WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
F6WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
F6WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
F6WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
F6WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
F6WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
F7WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
F7WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
F7WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
F7WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
F7WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
F7WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
F8WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
F8WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
F8WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
F8WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
F8WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
F8WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
F9WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
F9WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
F9WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
F9WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
F9WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
F9WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
TWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
TWINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
TWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
TWINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
TWINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
G SW APARTMENT_LIGHTS_HARDWIRED | G SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G NW APARTMENT_LIGHTS_HARDWIRED | G NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
OFFICE_LIGHTS_HARDWIRED | OFFICE | 14.7681 | 88.25 | 1303.26 | GeneralLights | LTG_OFF_SCH | 62.05 | 168.00 | 61.07 | 0.0000 | Y | 14.94 |
G NE APARTMENT_LIGHTS_HARDWIRED | G NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G N1 APARTMENT_LIGHTS_HARDWIRED | G N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G N2 APARTMENT_LIGHTS_HARDWIRED | G N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G S1 APARTMENT_LIGHTS_HARDWIRED | G S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G S2 APARTMENT_LIGHTS_HARDWIRED | G S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G CORRIDOR_LIGHTS_HARDWIRED | G CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F2 SW APARTMENT_LIGHTS_HARDWIRED | F2 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 NW APARTMENT_LIGHTS_HARDWIRED | F2 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 SE APARTMENT_LIGHTS_HARDWIRED | F2 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 NE APARTMENT_LIGHTS_HARDWIRED | F2 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 N1 APARTMENT_LIGHTS_HARDWIRED | F2 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 N2 APARTMENT_LIGHTS_HARDWIRED | F2 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 S1 APARTMENT_LIGHTS_HARDWIRED | F2 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 S2 APARTMENT_LIGHTS_HARDWIRED | F2 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 CORRIDOR_LIGHTS_HARDWIRED | F2 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F3 SW APARTMENT_LIGHTS_HARDWIRED | F3 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 NW APARTMENT_LIGHTS_HARDWIRED | F3 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 SE APARTMENT_LIGHTS_HARDWIRED | F3 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 NE APARTMENT_LIGHTS_HARDWIRED | F3 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 N1 APARTMENT_LIGHTS_HARDWIRED | F3 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 N2 APARTMENT_LIGHTS_HARDWIRED | F3 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 S1 APARTMENT_LIGHTS_HARDWIRED | F3 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 S2 APARTMENT_LIGHTS_HARDWIRED | F3 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 CORRIDOR_LIGHTS_HARDWIRED | F3 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F4 SW APARTMENT_LIGHTS_HARDWIRED | F4 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 NW APARTMENT_LIGHTS_HARDWIRED | F4 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 SE APARTMENT_LIGHTS_HARDWIRED | F4 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 NE APARTMENT_LIGHTS_HARDWIRED | F4 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 N1 APARTMENT_LIGHTS_HARDWIRED | F4 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 N2 APARTMENT_LIGHTS_HARDWIRED | F4 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 S1 APARTMENT_LIGHTS_HARDWIRED | F4 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 S2 APARTMENT_LIGHTS_HARDWIRED | F4 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 CORRIDOR_LIGHTS_HARDWIRED | F4 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
M SW APARTMENT_LIGHTS_HARDWIRED | M SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M NW APARTMENT_LIGHTS_HARDWIRED | M NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M SE APARTMENT_LIGHTS_HARDWIRED | M SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M NE APARTMENT_LIGHTS_HARDWIRED | M NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M N1 APARTMENT_LIGHTS_HARDWIRED | M N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M N2 APARTMENT_LIGHTS_HARDWIRED | M N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M S1 APARTMENT_LIGHTS_HARDWIRED | M S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M S2 APARTMENT_LIGHTS_HARDWIRED | M S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M CORRIDOR_LIGHTS_HARDWIRED | M CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F6 SW APARTMENT_LIGHTS_HARDWIRED | F6 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 NW APARTMENT_LIGHTS_HARDWIRED | F6 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 SE APARTMENT_LIGHTS_HARDWIRED | F6 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 NE APARTMENT_LIGHTS_HARDWIRED | F6 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 N1 APARTMENT_LIGHTS_HARDWIRED | F6 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 N2 APARTMENT_LIGHTS_HARDWIRED | F6 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 S1 APARTMENT_LIGHTS_HARDWIRED | F6 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 S2 APARTMENT_LIGHTS_HARDWIRED | F6 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 CORRIDOR_LIGHTS_HARDWIRED | F6 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F7 SW APARTMENT_LIGHTS_HARDWIRED | F7 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 NW APARTMENT_LIGHTS_HARDWIRED | F7 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 SE APARTMENT_LIGHTS_HARDWIRED | F7 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 NE APARTMENT_LIGHTS_HARDWIRED | F7 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 N1 APARTMENT_LIGHTS_HARDWIRED | F7 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 N2 APARTMENT_LIGHTS_HARDWIRED | F7 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 S1 APARTMENT_LIGHTS_HARDWIRED | F7 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 S2 APARTMENT_LIGHTS_HARDWIRED | F7 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 CORRIDOR_LIGHTS_HARDWIRED | F7 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F8 SW APARTMENT_LIGHTS_HARDWIRED | F8 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 NW APARTMENT_LIGHTS_HARDWIRED | F8 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 SE APARTMENT_LIGHTS_HARDWIRED | F8 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 NE APARTMENT_LIGHTS_HARDWIRED | F8 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 N1 APARTMENT_LIGHTS_HARDWIRED | F8 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 N2 APARTMENT_LIGHTS_HARDWIRED | F8 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 S1 APARTMENT_LIGHTS_HARDWIRED | F8 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 S2 APARTMENT_LIGHTS_HARDWIRED | F8 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 CORRIDOR_LIGHTS_HARDWIRED | F8 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F9 SW APARTMENT_LIGHTS_HARDWIRED | F9 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 NW APARTMENT_LIGHTS_HARDWIRED | F9 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 SE APARTMENT_LIGHTS_HARDWIRED | F9 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 NE APARTMENT_LIGHTS_HARDWIRED | F9 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 N1 APARTMENT_LIGHTS_HARDWIRED | F9 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 N2 APARTMENT_LIGHTS_HARDWIRED | F9 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 S1 APARTMENT_LIGHTS_HARDWIRED | F9 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 S2 APARTMENT_LIGHTS_HARDWIRED | F9 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 CORRIDOR_LIGHTS_HARDWIRED | F9 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
T SW APARTMENT_LIGHTS_HARDWIRED | T SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T NW APARTMENT_LIGHTS_HARDWIRED | T NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T SE APARTMENT_LIGHTS_HARDWIRED | T SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T NE APARTMENT_LIGHTS_HARDWIRED | T NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T N1 APARTMENT_LIGHTS_HARDWIRED | T N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T N2 APARTMENT_LIGHTS_HARDWIRED | T N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T S1 APARTMENT_LIGHTS_HARDWIRED | T S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T S2 APARTMENT_LIGHTS_HARDWIRED | T S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T CORRIDOR_LIGHTS_HARDWIRED | T CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
G SW APARTMENT_LIGHTS_PLUGIN | G SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G NW APARTMENT_LIGHTS_PLUGIN | G NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
OFFICE_LIGHTS_PLUGIN | OFFICE | 14.7681 | 88.25 | 1303.26 | GeneralLights-plugin | LTG_OFF_SCH | 62.05 | 168.00 | 61.07 | 0.0000 | Y | 14.94 |
G NE APARTMENT_LIGHTS_PLUGIN | G NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G N1 APARTMENT_LIGHTS_PLUGIN | G N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G N2 APARTMENT_LIGHTS_PLUGIN | G N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G S1 APARTMENT_LIGHTS_PLUGIN | G S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G S2 APARTMENT_LIGHTS_PLUGIN | G S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 SW APARTMENT_LIGHTS_PLUGIN | F2 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 NW APARTMENT_LIGHTS_PLUGIN | F2 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 SE APARTMENT_LIGHTS_PLUGIN | F2 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 NE APARTMENT_LIGHTS_PLUGIN | F2 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 N1 APARTMENT_LIGHTS_PLUGIN | F2 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 N2 APARTMENT_LIGHTS_PLUGIN | F2 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 S1 APARTMENT_LIGHTS_PLUGIN | F2 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 S2 APARTMENT_LIGHTS_PLUGIN | F2 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 SW APARTMENT_LIGHTS_PLUGIN | F3 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 NW APARTMENT_LIGHTS_PLUGIN | F3 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 SE APARTMENT_LIGHTS_PLUGIN | F3 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 NE APARTMENT_LIGHTS_PLUGIN | F3 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 N1 APARTMENT_LIGHTS_PLUGIN | F3 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 N2 APARTMENT_LIGHTS_PLUGIN | F3 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 S1 APARTMENT_LIGHTS_PLUGIN | F3 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 S2 APARTMENT_LIGHTS_PLUGIN | F3 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 SW APARTMENT_LIGHTS_PLUGIN | F4 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 NW APARTMENT_LIGHTS_PLUGIN | F4 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 SE APARTMENT_LIGHTS_PLUGIN | F4 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 NE APARTMENT_LIGHTS_PLUGIN | F4 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 N1 APARTMENT_LIGHTS_PLUGIN | F4 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 N2 APARTMENT_LIGHTS_PLUGIN | F4 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 S1 APARTMENT_LIGHTS_PLUGIN | F4 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 S2 APARTMENT_LIGHTS_PLUGIN | F4 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M SW APARTMENT_LIGHTS_PLUGIN | M SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M NW APARTMENT_LIGHTS_PLUGIN | M NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M SE APARTMENT_LIGHTS_PLUGIN | M SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M NE APARTMENT_LIGHTS_PLUGIN | M NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M N1 APARTMENT_LIGHTS_PLUGIN | M N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M N2 APARTMENT_LIGHTS_PLUGIN | M N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M S1 APARTMENT_LIGHTS_PLUGIN | M S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M S2 APARTMENT_LIGHTS_PLUGIN | M S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M CORRIDOR_LIGHTS_PLUGIN | M CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights-plugin | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F6 SW APARTMENT_LIGHTS_PLUGIN | F6 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 NW APARTMENT_LIGHTS_PLUGIN | F6 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 SE APARTMENT_LIGHTS_PLUGIN | F6 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 NE APARTMENT_LIGHTS_PLUGIN | F6 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 N1 APARTMENT_LIGHTS_PLUGIN | F6 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 N2 APARTMENT_LIGHTS_PLUGIN | F6 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 S1 APARTMENT_LIGHTS_PLUGIN | F6 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 S2 APARTMENT_LIGHTS_PLUGIN | F6 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 SW APARTMENT_LIGHTS_PLUGIN | F7 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 NW APARTMENT_LIGHTS_PLUGIN | F7 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 SE APARTMENT_LIGHTS_PLUGIN | F7 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 NE APARTMENT_LIGHTS_PLUGIN | F7 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 N1 APARTMENT_LIGHTS_PLUGIN | F7 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 N2 APARTMENT_LIGHTS_PLUGIN | F7 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 S1 APARTMENT_LIGHTS_PLUGIN | F7 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 S2 APARTMENT_LIGHTS_PLUGIN | F7 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 SW APARTMENT_LIGHTS_PLUGIN | F8 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 NW APARTMENT_LIGHTS_PLUGIN | F8 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 SE APARTMENT_LIGHTS_PLUGIN | F8 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 NE APARTMENT_LIGHTS_PLUGIN | F8 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 N1 APARTMENT_LIGHTS_PLUGIN | F8 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 N2 APARTMENT_LIGHTS_PLUGIN | F8 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 S1 APARTMENT_LIGHTS_PLUGIN | F8 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 S2 APARTMENT_LIGHTS_PLUGIN | F8 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 SW APARTMENT_LIGHTS_PLUGIN | F9 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 NW APARTMENT_LIGHTS_PLUGIN | F9 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 SE APARTMENT_LIGHTS_PLUGIN | F9 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 NE APARTMENT_LIGHTS_PLUGIN | F9 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 N1 APARTMENT_LIGHTS_PLUGIN | F9 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 N2 APARTMENT_LIGHTS_PLUGIN | F9 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 S1 APARTMENT_LIGHTS_PLUGIN | F9 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 S2 APARTMENT_LIGHTS_PLUGIN | F9 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T SW APARTMENT_LIGHTS_PLUGIN | T SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T NW APARTMENT_LIGHTS_PLUGIN | T NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T SE APARTMENT_LIGHTS_PLUGIN | T SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T NE APARTMENT_LIGHTS_PLUGIN | T NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T N1 APARTMENT_LIGHTS_PLUGIN | T N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T N2 APARTMENT_LIGHTS_PLUGIN | T N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T S1 APARTMENT_LIGHTS_PLUGIN | T S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T S2 APARTMENT_LIGHTS_PLUGIN | T S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
Interior Lighting Total | 2.2679 | 14974.03 | 33959.19 | 296.56 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 10364.00 | AstronomicalClock | - | 83.62 | 83.62 | 162.68 | |
Exterior Lighting Total | 10364.00 | 162.68 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
CENTRAL BOILER | Boiler:HotWater | 343550.24 | 0.75 | ||
CENTRAL TOWER | EvaporativeFluidCooler:SingleSpeed | 274840.19 |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
HEAT PUMP COOLING MODE AIRLOOP G SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4140.37 | 2697.65 | 1442.72 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3911.89 | 2531.58 | 1380.31 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP OFFICE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6065.88 | 4013.16 | 2052.72 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3398.08 | 2133.35 | 1264.73 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2483.70 | 1510.60 | 973.10 | 0.61 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2495.49 | 1515.11 | 980.38 | 0.61 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2818.88 | 1759.22 | 1059.66 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2909.06 | 1825.57 | 1083.50 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5223.49 | 3452.12 | 1771.37 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4919.15 | 3227.28 | 1691.87 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5097.48 | 3353.19 | 1744.30 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3965.61 | 2538.79 | 1426.82 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2928.72 | 1828.34 | 1100.38 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2907.84 | 1813.38 | 1094.46 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3550.23 | 2270.19 | 1280.04 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3583.17 | 2294.59 | 1288.58 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5339.02 | 3506.78 | 1832.23 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5043.96 | 3289.78 | 1754.18 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4928.50 | 3198.05 | 1730.45 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4100.64 | 2610.28 | 1490.36 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3038.46 | 1892.14 | 1146.32 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3018.11 | 1877.60 | 1140.51 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3652.42 | 2328.82 | 1323.60 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3667.67 | 2340.12 | 1327.56 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5425.18 | 3547.88 | 1877.30 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5130.31 | 3331.71 | 1798.59 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4988.88 | 3221.24 | 1767.64 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4176.10 | 2646.52 | 1529.58 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3098.50 | 1925.21 | 1173.28 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3078.14 | 1910.72 | 1167.42 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3711.32 | 2359.82 | 1351.50 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3724.07 | 2369.25 | 1354.83 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5524.31 | 3602.91 | 1921.39 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5230.08 | 3387.70 | 1842.38 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5087.12 | 3276.40 | 1810.72 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4266.51 | 2697.19 | 1569.32 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3175.15 | 1972.09 | 1203.06 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3154.84 | 1957.66 | 1197.19 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3786.74 | 2405.21 | 1381.52 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3799.14 | 2414.37 | 1384.77 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5532.66 | 3593.88 | 1938.77 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5236.44 | 3377.90 | 1858.54 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5097.36 | 3269.76 | 1827.60 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4264.65 | 2683.71 | 1580.94 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3163.78 | 1957.24 | 1206.54 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3143.50 | 1942.89 | 1200.61 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3775.80 | 2388.96 | 1386.84 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3788.19 | 2398.08 | 1390.11 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5564.48 | 3604.19 | 1960.29 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5267.73 | 3388.33 | 1879.39 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5133.63 | 3283.67 | 1849.96 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4288.45 | 2690.45 | 1598.00 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3178.75 | 1962.18 | 1216.57 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3158.50 | 1947.90 | 1210.60 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3790.41 | 2392.51 | 1397.90 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3802.82 | 2401.62 | 1401.20 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5610.30 | 3626.22 | 1984.07 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5313.34 | 3410.63 | 1902.71 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5180.76 | 3307.28 | 1873.48 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4437.62 | 2778.16 | 1659.46 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3210.23 | 1979.50 | 1230.73 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3190.06 | 1965.30 | 1224.76 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3820.21 | 2407.90 | 1412.31 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3832.67 | 2417.03 | 1415.63 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5783.24 | 3742.31 | 2040.93 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5486.55 | 3526.71 | 1959.84 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5323.66 | 3401.35 | 1922.31 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4722.30 | 2955.68 | 1766.62 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3353.34 | 2076.41 | 1276.93 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3332.96 | 2062.02 | 1270.94 | 0.62 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3934.56 | 2484.77 | 1449.79 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3946.82 | 2493.76 | 1453.06 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6795.65 | 4472.85 | 2322.79 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6351.30 | 4148.29 | 2203.00 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6250.34 | 4070.40 | 2179.94 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5382.81 | 3423.33 | 1959.48 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4048.81 | 2562.07 | 1486.74 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4044.25 | 2558.67 | 1485.59 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4989.41 | 3253.82 | 1735.59 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5000.97 | 3262.48 | 1738.49 | 0.65 | 0.00 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
None |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
HEAT PUMP HEATING MODE AIRLOOP G SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4140.37 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 3911.89 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP OFFICE | Coil:Heating:WaterToAirHeatPump:EquationFit | 6065.88 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3398.08 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2483.70 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2495.49 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2818.88 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2909.06 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5223.49 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4919.15 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5097.48 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3965.61 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2928.72 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2907.84 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3550.23 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3583.17 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5339.02 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5043.96 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4928.50 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4100.64 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3038.46 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3018.11 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3652.42 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3667.67 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5425.18 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5130.31 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4988.88 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4176.10 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3098.50 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3078.14 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3711.32 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3724.07 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5524.31 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5230.08 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5087.12 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4266.51 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3175.15 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3154.84 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3786.74 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3799.14 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5532.66 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5236.44 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5097.36 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4264.65 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3163.78 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3143.50 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3775.80 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3788.19 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5564.48 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5267.73 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5133.63 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4288.45 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3178.75 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3158.50 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3790.41 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3802.82 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5610.30 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5313.34 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5180.76 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4437.62 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3210.23 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3190.06 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3820.21 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3832.67 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5783.24 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5486.55 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5323.66 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4722.30 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3353.34 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3332.96 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3934.56 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3946.82 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 6795.65 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 6351.30 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 6250.34 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5382.81 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4048.81 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4044.25 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4989.41 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 5000.97 | 0.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW | Coil:Heating:Electric | 4974.82 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW | Coil:Heating:Electric | 4983.32 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE | Coil:Heating:Electric | 5979.01 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE | Coil:Heating:Electric | 4984.60 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 | Coil:Heating:Electric | 3766.89 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 | Coil:Heating:Electric | 3766.90 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 | Coil:Heating:Electric | 3755.65 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 | Coil:Heating:Electric | 3761.92 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW | Coil:Heating:Electric | 5061.34 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW | Coil:Heating:Electric | 5060.36 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE | Coil:Heating:Electric | 5075.81 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE | Coil:Heating:Electric | 5056.73 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 | Coil:Heating:Electric | 3518.09 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 | Coil:Heating:Electric | 3518.01 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 | Coil:Heating:Electric | 3522.03 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 | Coil:Heating:Electric | 3523.07 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW | Coil:Heating:Electric | 5232.35 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW | Coil:Heating:Electric | 5233.48 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE | Coil:Heating:Electric | 5227.27 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE | Coil:Heating:Electric | 5226.56 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 | Coil:Heating:Electric | 3572.22 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 | Coil:Heating:Electric | 3572.07 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 | Coil:Heating:Electric | 3572.11 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 | Coil:Heating:Electric | 3572.12 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW | Coil:Heating:Electric | 5438.29 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW | Coil:Heating:Electric | 5440.17 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE | Coil:Heating:Electric | 5429.22 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE | Coil:Heating:Electric | 5430.93 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 | Coil:Heating:Electric | 3685.72 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 | Coil:Heating:Electric | 3685.51 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 | Coil:Heating:Electric | 3684.57 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 | Coil:Heating:Electric | 3684.38 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW | Coil:Heating:Electric | 5598.62 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW | Coil:Heating:Electric | 5599.65 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE | Coil:Heating:Electric | 5587.60 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE | Coil:Heating:Electric | 5588.63 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 | Coil:Heating:Electric | 3770.20 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 | Coil:Heating:Electric | 3769.95 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 | Coil:Heating:Electric | 3769.82 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 | Coil:Heating:Electric | 3769.57 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW | Coil:Heating:Electric | 5800.24 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW | Coil:Heating:Electric | 5802.18 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE | Coil:Heating:Electric | 5787.77 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE | Coil:Heating:Electric | 5789.71 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 | Coil:Heating:Electric | 3906.26 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 | Coil:Heating:Electric | 3905.98 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 | Coil:Heating:Electric | 3904.98 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 | Coil:Heating:Electric | 3904.70 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW | Coil:Heating:Electric | 5961.20 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW | Coil:Heating:Electric | 5962.91 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE | Coil:Heating:Electric | 5947.53 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE | Coil:Heating:Electric | 5949.24 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 | Coil:Heating:Electric | 4009.59 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 | Coil:Heating:Electric | 4009.28 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 | Coil:Heating:Electric | 4008.54 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 | Coil:Heating:Electric | 4008.23 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW | Coil:Heating:Electric | 6119.02 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW | Coil:Heating:Electric | 6120.17 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE | Coil:Heating:Electric | 6104.33 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE | Coil:Heating:Electric | 6105.48 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 | Coil:Heating:Electric | 4115.49 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 | Coil:Heating:Electric | 4115.16 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 | Coil:Heating:Electric | 4114.99 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 | Coil:Heating:Electric | 4114.66 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW | Coil:Heating:Electric | 6426.33 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW | Coil:Heating:Electric | 6423.71 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE | Coil:Heating:Electric | 6410.61 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE | Coil:Heating:Electric | 6407.99 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 | Coil:Heating:Electric | 4361.60 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 | Coil:Heating:Electric | 4361.25 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 | Coil:Heating:Electric | 4364.47 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 | Coil:Heating:Electric | 4364.12 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW | Coil:Heating:Electric | 7306.56 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW | Coil:Heating:Electric | 7312.16 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE | Coil:Heating:Electric | 7291.30 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE | Coil:Heating:Electric | 7296.89 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 | Coil:Heating:Electric | 5280.17 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 | Coil:Heating:Electric | 5279.80 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 | Coil:Heating:Electric | 5271.94 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 | Coil:Heating:Electric | 5271.57 | 1.00 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
AIRLOOP G SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 260.10 | 1160.84 | 1.00 | General |
AIRLOOP G NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 243.15 | 1160.84 | 1.00 | General |
AIRLOOP OFFICE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.34 | 391.53 | 1160.84 | 1.00 | General |
AIRLOOP G NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 198.93 | 1160.84 | 1.00 | General |
AIRLOOP G N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.12 | 133.57 | 1160.84 | 1.00 | General |
AIRLOOP G N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.12 | 133.57 | 1160.84 | 1.00 | General |
AIRLOOP G S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.14 | 159.65 | 1160.84 | 1.00 | General |
AIRLOOP G S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.14 | 166.94 | 1160.84 | 1.00 | General |
AIRLOOP F2 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.29 | 339.25 | 1160.84 | 1.00 | General |
AIRLOOP F2 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 315.58 | 1160.84 | 1.00 | General |
AIRLOOP F2 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 327.21 | 1160.84 | 1.00 | General |
AIRLOOP F2 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 242.76 | 1160.84 | 1.00 | General |
AIRLOOP F2 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 168.58 | 1160.84 | 1.00 | General |
AIRLOOP F2 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.14 | 166.95 | 1160.84 | 1.00 | General |
AIRLOOP F2 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 213.32 | 1160.84 | 1.00 | General |
AIRLOOP F2 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 216.00 | 1160.84 | 1.00 | General |
AIRLOOP F3 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 342.88 | 1160.84 | 1.00 | General |
AIRLOOP F3 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 320.09 | 1160.84 | 1.00 | General |
AIRLOOP F3 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 307.86 | 1160.84 | 1.00 | General |
AIRLOOP F3 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 247.87 | 1160.84 | 1.00 | General |
AIRLOOP F3 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 173.77 | 1160.84 | 1.00 | General |
AIRLOOP F3 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 172.19 | 1160.84 | 1.00 | General |
AIRLOOP F3 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 218.35 | 1160.84 | 1.00 | General |
AIRLOOP F3 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 219.60 | 1160.84 | 1.00 | General |
AIRLOOP F4 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 345.62 | 1160.84 | 1.00 | General |
AIRLOOP F4 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 322.94 | 1160.84 | 1.00 | General |
AIRLOOP F4 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 308.68 | 1160.84 | 1.00 | General |
AIRLOOP F4 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 250.16 | 1160.84 | 1.00 | General |
AIRLOOP F4 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 176.38 | 1160.84 | 1.00 | General |
AIRLOOP F4 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 174.81 | 1160.84 | 1.00 | General |
AIRLOOP F4 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 220.70 | 1160.84 | 1.00 | General |
AIRLOOP F4 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 221.74 | 1160.84 | 1.00 | General |
AIRLOOP M SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 350.22 | 1160.84 | 1.00 | General |
AIRLOOP M NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 327.66 | 1160.84 | 1.00 | General |
AIRLOOP M SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 313.31 | 1160.84 | 1.00 | General |
AIRLOOP M NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 254.34 | 1160.84 | 1.00 | General |
AIRLOOP M N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 180.69 | 1160.84 | 1.00 | General |
AIRLOOP M N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 179.13 | 1160.84 | 1.00 | General |
AIRLOOP M S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 224.82 | 1160.84 | 1.00 | General |
AIRLOOP M S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 225.83 | 1160.84 | 1.00 | General |
AIRLOOP F6 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 348.02 | 1160.84 | 1.00 | General |
AIRLOOP F6 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 325.39 | 1160.84 | 1.00 | General |
AIRLOOP F6 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 311.40 | 1160.84 | 1.00 | General |
AIRLOOP F6 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 251.73 | 1160.84 | 1.00 | General |
AIRLOOP F6 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 178.38 | 1160.84 | 1.00 | General |
AIRLOOP F6 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 176.83 | 1160.84 | 1.00 | General |
AIRLOOP F6 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 222.32 | 1160.84 | 1.00 | General |
AIRLOOP F6 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 223.32 | 1160.84 | 1.00 | General |
AIRLOOP F7 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 348.08 | 1160.84 | 1.00 | General |
AIRLOOP F7 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 325.48 | 1160.84 | 1.00 | General |
AIRLOOP F7 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 311.73 | 1160.84 | 1.00 | General |
AIRLOOP F7 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 251.46 | 1160.84 | 1.00 | General |
AIRLOOP F7 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 178.32 | 1160.84 | 1.00 | General |
AIRLOOP F7 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 176.78 | 1160.84 | 1.00 | General |
AIRLOOP F7 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 222.07 | 1160.84 | 1.00 | General |
AIRLOOP F7 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 223.08 | 1160.84 | 1.00 | General |
AIRLOOP F8 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 349.54 | 1160.84 | 1.00 | General |
AIRLOOP F8 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 326.98 | 1160.84 | 1.00 | General |
AIRLOOP F8 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 313.38 | 1160.84 | 1.00 | General |
AIRLOOP F8 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 259.03 | 1160.84 | 1.00 | General |
AIRLOOP F8 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 179.67 | 1160.84 | 1.00 | General |
AIRLOOP F8 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 178.14 | 1160.84 | 1.00 | General |
AIRLOOP F8 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 223.19 | 1160.84 | 1.00 | General |
AIRLOOP F8 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 224.19 | 1160.84 | 1.00 | General |
AIRLOOP F9 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 361.35 | 1160.84 | 1.00 | General |
AIRLOOP F9 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.29 | 338.79 | 1160.84 | 1.00 | General |
AIRLOOP F9 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 322.78 | 1160.84 | 1.00 | General |
AIRLOOP F9 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 275.26 | 1160.84 | 1.00 | General |
AIRLOOP F9 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 189.72 | 1160.84 | 1.00 | General |
AIRLOOP F9 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 188.17 | 1160.84 | 1.00 | General |
AIRLOOP F9 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.20 | 230.92 | 1160.84 | 1.00 | General |
AIRLOOP F9 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.20 | 231.91 | 1160.84 | 1.00 | General |
AIRLOOP T SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.38 | 439.24 | 1160.84 | 1.00 | General |
AIRLOOP T NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.35 | 404.66 | 1160.84 | 1.00 | General |
AIRLOOP T SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.34 | 395.24 | 1160.84 | 1.00 | General |
AIRLOOP T NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 322.95 | 1160.84 | 1.00 | General |
AIRLOOP T N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 238.74 | 1160.84 | 1.00 | General |
AIRLOOP T N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 238.36 | 1160.84 | 1.00 | General |
AIRLOOP T S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 314.72 | 1160.84 | 1.00 | General |
AIRLOOP T S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 315.67 | 1160.84 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
SHWSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.0003 | 36.93 | 127739.32 | 0.30 |
PLANT CIRC PUMP | Pump:ConstantSpeed | Intermittent | 224180.02 | 0.0075 | 2386.30 | 319344.75 | 0.90 |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SHWSYS1 WATER HEATER | WaterHeater:Mixed | 2.27 | 175842.64 | 0.80 | 0.00 | 0.00 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 2328.04 | 2793.65 | 0.187 | 0.224 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 32.25 | 0.01496 |
G NW APARTMENT | 2176.40 | 2611.68 | 0.175 | 0.209 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 31.04 | 0.01496 |
OFFICE | 3504.42 | 4205.30 | 0.281 | 0.337 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:15:00 | 32.91 | 0.01496 |
G NE APARTMENT | 1605.44 | 1926.53 | 0.129 | 0.155 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 09:45:00 | 28.86 | 0.01496 |
G N1 APARTMENT | 1106.69 | 1328.03 | 0.089 | 0.107 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:45:00 | 29.60 | 0.01496 |
G N2 APARTMENT | 1089.40 | 1307.28 | 0.087 | 0.105 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:45:00 | 29.60 | 0.01496 |
G S1 APARTMENT | 1429.05 | 1714.86 | 0.115 | 0.138 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
G S2 APARTMENT | 1494.27 | 1793.12 | 0.120 | 0.144 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
F2 SW APARTMENT | 3036.29 | 3643.55 | 0.244 | 0.292 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 32.04 | 0.01496 |
F2 NW APARTMENT | 2824.55 | 3389.46 | 0.227 | 0.272 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 31.04 | 0.01496 |
F2 SE APARTMENT | 2928.56 | 3514.28 | 0.235 | 0.282 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:15:00 | 32.91 | 0.01496 |
F2 NE APARTMENT | 2172.68 | 2607.22 | 0.174 | 0.209 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:00:00 | 29.31 | 0.01496 |
F2 N1 APARTMENT | 1508.96 | 1810.76 | 0.121 | 0.145 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:45:00 | 29.60 | 0.01496 |
F2 N2 APARTMENT | 1494.38 | 1793.26 | 0.120 | 0.144 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:45:00 | 29.60 | 0.01496 |
F2 S1 APARTMENT | 1909.39 | 2291.27 | 0.153 | 0.184 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
F2 S2 APARTMENT | 1933.39 | 2320.07 | 0.155 | 0.186 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
F3 SW APARTMENT | 3068.69 | 3682.43 | 0.246 | 0.295 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 32.04 | 0.01496 |
F3 NW APARTMENT | 2864.89 | 3437.86 | 0.230 | 0.276 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 31.04 | 0.01496 |
F3 SE APARTMENT | 2755.30 | 3306.36 | 0.221 | 0.265 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:15:00 | 32.91 | 0.01496 |
F3 NE APARTMENT | 2218.37 | 2662.04 | 0.178 | 0.214 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 29.70 | 0.01496 |
F3 N1 APARTMENT | 1555.38 | 1866.46 | 0.125 | 0.150 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 29.99 | 0.01496 |
F3 N2 APARTMENT | 1541.23 | 1849.47 | 0.124 | 0.148 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 29.99 | 0.01496 |
F3 S1 APARTMENT | 1954.36 | 2345.24 | 0.157 | 0.188 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
F3 S2 APARTMENT | 1965.49 | 2358.59 | 0.158 | 0.189 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
F4 SW APARTMENT | 3093.17 | 3711.80 | 0.248 | 0.298 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 32.04 | 0.01496 |
F4 NW APARTMENT | 2890.36 | 3468.43 | 0.232 | 0.278 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 31.04 | 0.01496 |
F4 SE APARTMENT | 2762.51 | 3315.01 | 0.222 | 0.266 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:15:00 | 32.91 | 0.01496 |
F4 NE APARTMENT | 2238.80 | 2686.57 | 0.180 | 0.216 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 29.70 | 0.01496 |
F4 N1 APARTMENT | 1578.76 | 1894.51 | 0.127 | 0.152 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 29.99 | 0.01496 |
F4 N2 APARTMENT | 1564.67 | 1877.61 | 0.125 | 0.151 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 29.99 | 0.01496 |
F4 S1 APARTMENT | 1975.36 | 2370.43 | 0.158 | 0.190 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
F4 S2 APARTMENT | 1984.65 | 2381.58 | 0.159 | 0.191 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
M SW APARTMENT | 3134.25 | 3761.10 | 0.251 | 0.302 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 32.04 | 0.01496 |
M NW APARTMENT | 2932.52 | 3519.03 | 0.235 | 0.282 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 31.04 | 0.01496 |
M SE APARTMENT | 2803.92 | 3364.70 | 0.225 | 0.270 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:15:00 | 32.91 | 0.01496 |
M NE APARTMENT | 2276.17 | 2731.40 | 0.183 | 0.219 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 29.70 | 0.01496 |
M N1 APARTMENT | 1617.32 | 1940.79 | 0.130 | 0.156 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 29.99 | 0.01496 |
M N2 APARTMENT | 1603.30 | 1923.96 | 0.129 | 0.154 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 29.99 | 0.01496 |
M S1 APARTMENT | 2012.17 | 2414.61 | 0.161 | 0.194 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
M S2 APARTMENT | 2021.20 | 2425.43 | 0.162 | 0.195 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
F6 SW APARTMENT | 3114.46 | 3737.35 | 0.250 | 0.300 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 32.04 | 0.01496 |
F6 NW APARTMENT | 2912.14 | 3494.56 | 0.234 | 0.280 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 31.04 | 0.01496 |
F6 SE APARTMENT | 2786.75 | 3344.09 | 0.224 | 0.268 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:15:00 | 32.91 | 0.01496 |
F6 NE APARTMENT | 2252.71 | 2703.26 | 0.181 | 0.217 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 29.70 | 0.01496 |
F6 N1 APARTMENT | 1596.62 | 1915.95 | 0.128 | 0.154 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 29.99 | 0.01496 |
F6 N2 APARTMENT | 1582.71 | 1899.26 | 0.127 | 0.152 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 29.99 | 0.01496 |
F6 S1 APARTMENT | 1989.77 | 2387.73 | 0.160 | 0.192 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
F6 S2 APARTMENT | 1998.76 | 2398.51 | 0.160 | 0.192 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
F7 SW APARTMENT | 3114.98 | 3737.97 | 0.250 | 0.300 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 32.04 | 0.01496 |
F7 NW APARTMENT | 2912.93 | 3495.51 | 0.234 | 0.280 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 31.04 | 0.01496 |
F7 SE APARTMENT | 2789.69 | 3347.63 | 0.224 | 0.269 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
F7 NE APARTMENT | 2250.32 | 2700.38 | 0.181 | 0.217 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 29.70 | 0.01496 |
F7 N1 APARTMENT | 1596.07 | 1915.28 | 0.128 | 0.154 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 29.99 | 0.01496 |
F7 N2 APARTMENT | 1582.24 | 1898.69 | 0.127 | 0.152 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 29.99 | 0.01496 |
F7 S1 APARTMENT | 1987.57 | 2385.08 | 0.159 | 0.191 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
F7 S2 APARTMENT | 1996.54 | 2395.85 | 0.160 | 0.192 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
F8 SW APARTMENT | 3127.98 | 3753.57 | 0.251 | 0.301 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 32.04 | 0.01496 |
F8 NW APARTMENT | 2926.30 | 3511.57 | 0.235 | 0.282 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 31.04 | 0.01496 |
F8 SE APARTMENT | 2804.42 | 3365.31 | 0.225 | 0.270 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
F8 NE APARTMENT | 2259.85 | 2711.82 | 0.181 | 0.218 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 29.70 | 0.01496 |
F8 N1 APARTMENT | 1608.15 | 1929.78 | 0.129 | 0.155 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 29.99 | 0.01496 |
F8 N2 APARTMENT | 1594.42 | 1913.30 | 0.128 | 0.153 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 29.99 | 0.01496 |
F8 S1 APARTMENT | 1997.54 | 2397.05 | 0.160 | 0.192 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
F8 S2 APARTMENT | 2006.52 | 2407.83 | 0.161 | 0.193 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
F9 SW APARTMENT | 3233.67 | 3880.40 | 0.259 | 0.311 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 32.04 | 0.01496 |
F9 NW APARTMENT | 3031.98 | 3638.38 | 0.243 | 0.292 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 31.04 | 0.01496 |
F9 SE APARTMENT | 2888.53 | 3466.24 | 0.232 | 0.278 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
F9 NE APARTMENT | 2309.48 | 2771.38 | 0.185 | 0.222 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 30.10 | 0.01496 |
F9 N1 APARTMENT | 1698.10 | 2037.72 | 0.136 | 0.163 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 29.99 | 0.01496 |
F9 N2 APARTMENT | 1684.18 | 2021.02 | 0.135 | 0.162 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 29.99 | 0.01496 |
F9 S1 APARTMENT | 2066.71 | 2480.05 | 0.166 | 0.199 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 33.17 | 0.01496 |
F9 S2 APARTMENT | 2075.56 | 2490.67 | 0.166 | 0.200 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 33.17 | 0.01496 |
T SW APARTMENT | 3930.51 | 4716.62 | 0.315 | 0.378 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 | 32.98 | 0.01496 |
T NW APARTMENT | 3621.04 | 4345.25 | 0.290 | 0.349 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 32.25 | 0.01496 |
T SE APARTMENT | 3536.81 | 4244.18 | 0.284 | 0.340 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:15:00 | 32.91 | 0.01496 |
T NE APARTMENT | 2824.83 | 3389.80 | 0.227 | 0.272 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.30 | 0.01496 |
T N1 APARTMENT | 2136.65 | 2563.98 | 0.171 | 0.206 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 33.30 | 0.01496 |
T N2 APARTMENT | 2133.26 | 2559.92 | 0.171 | 0.205 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 33.30 | 0.01496 |
T S1 APARTMENT | 2816.61 | 3379.94 | 0.226 | 0.271 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
T S2 APARTMENT | 2825.18 | 3390.21 | 0.227 | 0.272 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 3125.64 | 3750.77 | 0.142 | 0.171 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -20.00 | 0.00065 |
G NW APARTMENT | 3132.83 | 3759.39 | 0.143 | 0.171 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -20.00 | 0.00065 |
OFFICE | 3468.57 | 4162.28 | 0.158 | 0.190 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 18:45:00 | -20.00 | 0.00065 |
G NE APARTMENT | 3133.92 | 3760.70 | 0.143 | 0.171 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -20.00 | 0.00065 |
G N1 APARTMENT | 2104.13 | 2524.96 | 0.096 | 0.115 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -20.00 | 0.00065 |
G N2 APARTMENT | 2104.15 | 2524.97 | 0.096 | 0.115 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -20.00 | 0.00065 |
G S1 APARTMENT | 2094.63 | 2513.55 | 0.095 | 0.115 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -20.00 | 0.00065 |
G S2 APARTMENT | 2099.93 | 2519.91 | 0.096 | 0.115 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -20.00 | 0.00065 |
F2 SW APARTMENT | 3198.87 | 3838.64 | 0.146 | 0.175 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F2 NW APARTMENT | 3198.04 | 3837.65 | 0.146 | 0.175 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F2 SE APARTMENT | 3211.11 | 3853.33 | 0.146 | 0.176 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F2 NE APARTMENT | 3194.97 | 3833.97 | 0.146 | 0.175 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F2 N1 APARTMENT | 1893.78 | 2272.54 | 0.086 | 0.104 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F2 N2 APARTMENT | 1893.71 | 2272.46 | 0.086 | 0.104 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F2 S1 APARTMENT | 1897.12 | 2276.54 | 0.086 | 0.104 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F2 S2 APARTMENT | 1897.99 | 2277.59 | 0.086 | 0.104 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F3 SW APARTMENT | 3343.51 | 4012.21 | 0.152 | 0.183 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F3 NW APARTMENT | 3344.46 | 4013.35 | 0.152 | 0.183 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F3 SE APARTMENT | 3339.21 | 4007.06 | 0.152 | 0.183 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F3 NE APARTMENT | 3338.61 | 4006.33 | 0.152 | 0.183 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F3 N1 APARTMENT | 1939.57 | 2327.48 | 0.088 | 0.106 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F3 N2 APARTMENT | 1939.44 | 2327.33 | 0.088 | 0.106 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F3 S1 APARTMENT | 1939.48 | 2327.37 | 0.088 | 0.106 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F3 S2 APARTMENT | 1939.48 | 2327.38 | 0.088 | 0.106 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F4 SW APARTMENT | 3517.67 | 4221.21 | 0.160 | 0.192 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F4 NW APARTMENT | 3519.27 | 4223.12 | 0.160 | 0.192 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F4 SE APARTMENT | 3510.00 | 4212.00 | 0.160 | 0.192 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F4 NE APARTMENT | 3511.45 | 4213.74 | 0.160 | 0.192 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F4 N1 APARTMENT | 2035.56 | 2442.67 | 0.093 | 0.111 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F4 N2 APARTMENT | 2035.38 | 2442.46 | 0.093 | 0.111 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F4 S1 APARTMENT | 2034.58 | 2441.50 | 0.093 | 0.111 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F4 S2 APARTMENT | 2034.42 | 2441.31 | 0.093 | 0.111 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
M SW APARTMENT | 3653.27 | 4383.92 | 0.166 | 0.200 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
M NW APARTMENT | 3654.14 | 4384.97 | 0.166 | 0.200 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
M SE APARTMENT | 3643.95 | 4372.75 | 0.166 | 0.199 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
M NE APARTMENT | 3644.82 | 4373.78 | 0.166 | 0.199 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
M N1 APARTMENT | 2107.01 | 2528.41 | 0.096 | 0.115 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
M N2 APARTMENT | 2106.79 | 2528.15 | 0.096 | 0.115 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
M S1 APARTMENT | 2106.68 | 2528.02 | 0.096 | 0.115 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
M S2 APARTMENT | 2106.47 | 2527.77 | 0.096 | 0.115 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F6 SW APARTMENT | 3823.78 | 4588.53 | 0.174 | 0.209 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F6 NW APARTMENT | 3825.42 | 4590.50 | 0.174 | 0.209 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F6 SE APARTMENT | 3813.23 | 4575.88 | 0.174 | 0.208 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F6 NE APARTMENT | 3814.87 | 4577.85 | 0.174 | 0.209 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F6 N1 APARTMENT | 2222.07 | 2666.49 | 0.101 | 0.121 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F6 N2 APARTMENT | 2221.83 | 2666.20 | 0.101 | 0.121 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F6 S1 APARTMENT | 2220.99 | 2665.19 | 0.101 | 0.121 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F6 S2 APARTMENT | 2220.75 | 2664.90 | 0.101 | 0.121 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F7 SW APARTMENT | 3959.90 | 4751.88 | 0.180 | 0.216 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F7 NW APARTMENT | 3961.35 | 4753.62 | 0.180 | 0.217 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F7 SE APARTMENT | 3948.34 | 4738.01 | 0.180 | 0.216 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F7 NE APARTMENT | 3949.79 | 4739.75 | 0.180 | 0.216 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F7 N1 APARTMENT | 2309.46 | 2771.35 | 0.105 | 0.126 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F7 N2 APARTMENT | 2309.19 | 2771.03 | 0.105 | 0.126 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F7 S1 APARTMENT | 2308.57 | 2770.28 | 0.105 | 0.126 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F7 S2 APARTMENT | 2308.31 | 2769.97 | 0.105 | 0.126 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F8 SW APARTMENT | 4093.37 | 4912.05 | 0.186 | 0.224 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F8 NW APARTMENT | 4094.35 | 4913.22 | 0.187 | 0.224 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F8 SE APARTMENT | 4080.95 | 4897.14 | 0.186 | 0.223 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F8 NE APARTMENT | 4081.92 | 4898.31 | 0.186 | 0.223 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F8 N1 APARTMENT | 2399.02 | 2878.82 | 0.109 | 0.131 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F8 N2 APARTMENT | 2398.74 | 2878.48 | 0.109 | 0.131 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F8 S1 APARTMENT | 2398.60 | 2878.32 | 0.109 | 0.131 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F8 S2 APARTMENT | 2398.32 | 2877.98 | 0.109 | 0.131 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F9 SW APARTMENT | 4353.26 | 5223.91 | 0.198 | 0.238 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F9 NW APARTMENT | 4351.04 | 5221.25 | 0.198 | 0.238 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F9 SE APARTMENT | 4339.96 | 5207.95 | 0.198 | 0.237 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F9 NE APARTMENT | 4337.75 | 5205.30 | 0.198 | 0.237 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F9 N1 APARTMENT | 2607.15 | 3128.58 | 0.119 | 0.143 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F9 N2 APARTMENT | 2606.85 | 3128.22 | 0.119 | 0.143 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F9 S1 APARTMENT | 2609.57 | 3131.49 | 0.119 | 0.143 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
F9 S2 APARTMENT | 2609.27 | 3131.13 | 0.119 | 0.143 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
T SW APARTMENT | 5097.64 | 6117.17 | 0.232 | 0.279 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
T NW APARTMENT | 5102.38 | 6122.85 | 0.232 | 0.279 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
T SE APARTMENT | 5084.74 | 6101.68 | 0.232 | 0.278 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
T NE APARTMENT | 5089.47 | 6107.36 | 0.232 | 0.278 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
T N1 APARTMENT | 3383.95 | 4060.74 | 0.154 | 0.185 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
T N2 APARTMENT | 3383.64 | 4060.36 | 0.154 | 0.185 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
T S1 APARTMENT | 3376.99 | 4052.38 | 0.154 | 0.185 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
T S2 APARTMENT | 3376.67 | 4052.01 | 0.154 | 0.185 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -20.00 | 0.00065 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
AIRLOOP G SW | 0.22 | 0.22 | 0.17 | 0.17 |
AIRLOOP G NW | 0.21 | 0.21 | 0.17 | 0.17 |
AIRLOOP OFFICE | 0.34 | 0.34 | 0.19 | 0.19 |
AIRLOOP G NE | 0.15 | 0.15 | 0.17 | 0.17 |
AIRLOOP G N1 | 0.11 | 0.11 | 0.12 | 0.12 |
AIRLOOP G N2 | 0.10 | 0.10 | 0.12 | 0.12 |
AIRLOOP G S1 | 0.14 | 0.14 | 0.11 | 0.11 |
AIRLOOP G S2 | 0.14 | 0.14 | 0.11 | 0.11 |
AIRLOOP F2 SW | 0.29 | 0.29 | 0.17 | 0.17 |
AIRLOOP F2 NW | 0.27 | 0.27 | 0.17 | 0.17 |
AIRLOOP F2 SE | 0.28 | 0.28 | 0.18 | 0.18 |
AIRLOOP F2 NE | 0.21 | 0.21 | 0.17 | 0.17 |
AIRLOOP F2 N1 | 0.15 | 0.15 | 0.10 | 0.10 |
AIRLOOP F2 N2 | 0.14 | 0.14 | 0.10 | 0.10 |
AIRLOOP F2 S1 | 0.18 | 0.18 | 0.10 | 0.10 |
AIRLOOP F2 S2 | 0.19 | 0.19 | 0.10 | 0.10 |
AIRLOOP F3 SW | 0.30 | 0.30 | 0.18 | 0.18 |
AIRLOOP F3 NW | 0.28 | 0.28 | 0.18 | 0.18 |
AIRLOOP F3 SE | 0.27 | 0.27 | 0.18 | 0.18 |
AIRLOOP F3 NE | 0.21 | 0.21 | 0.18 | 0.18 |
AIRLOOP F3 N1 | 0.15 | 0.15 | 0.11 | 0.11 |
AIRLOOP F3 N2 | 0.15 | 0.15 | 0.11 | 0.11 |
AIRLOOP F3 S1 | 0.19 | 0.19 | 0.11 | 0.11 |
AIRLOOP F3 S2 | 0.19 | 0.19 | 0.11 | 0.11 |
AIRLOOP F4 SW | 0.30 | 0.30 | 0.19 | 0.19 |
AIRLOOP F4 NW | 0.28 | 0.28 | 0.19 | 0.19 |
AIRLOOP F4 SE | 0.27 | 0.27 | 0.19 | 0.19 |
AIRLOOP F4 NE | 0.22 | 0.22 | 0.19 | 0.19 |
AIRLOOP F4 N1 | 0.15 | 0.15 | 0.11 | 0.11 |
AIRLOOP F4 N2 | 0.15 | 0.15 | 0.11 | 0.11 |
AIRLOOP F4 S1 | 0.19 | 0.19 | 0.11 | 0.11 |
AIRLOOP F4 S2 | 0.19 | 0.19 | 0.11 | 0.11 |
AIRLOOP M SW | 0.30 | 0.30 | 0.20 | 0.20 |
AIRLOOP M NW | 0.28 | 0.28 | 0.20 | 0.20 |
AIRLOOP M SE | 0.27 | 0.27 | 0.20 | 0.20 |
AIRLOOP M NE | 0.22 | 0.22 | 0.20 | 0.20 |
AIRLOOP M N1 | 0.16 | 0.16 | 0.12 | 0.12 |
AIRLOOP M N2 | 0.15 | 0.15 | 0.12 | 0.12 |
AIRLOOP M S1 | 0.19 | 0.19 | 0.12 | 0.12 |
AIRLOOP M S2 | 0.19 | 0.19 | 0.12 | 0.12 |
AIRLOOP F6 SW | 0.30 | 0.30 | 0.21 | 0.21 |
AIRLOOP F6 NW | 0.28 | 0.28 | 0.21 | 0.21 |
AIRLOOP F6 SE | 0.27 | 0.27 | 0.21 | 0.21 |
AIRLOOP F6 NE | 0.22 | 0.22 | 0.21 | 0.21 |
AIRLOOP F6 N1 | 0.15 | 0.15 | 0.12 | 0.12 |
AIRLOOP F6 N2 | 0.15 | 0.15 | 0.12 | 0.12 |
AIRLOOP F6 S1 | 0.19 | 0.19 | 0.12 | 0.12 |
AIRLOOP F6 S2 | 0.19 | 0.19 | 0.12 | 0.12 |
AIRLOOP F7 SW | 0.30 | 0.30 | 0.22 | 0.22 |
AIRLOOP F7 NW | 0.28 | 0.28 | 0.22 | 0.22 |
AIRLOOP F7 SE | 0.27 | 0.27 | 0.22 | 0.22 |
AIRLOOP F7 NE | 0.22 | 0.22 | 0.22 | 0.22 |
AIRLOOP F7 N1 | 0.15 | 0.15 | 0.13 | 0.13 |
AIRLOOP F7 N2 | 0.15 | 0.15 | 0.13 | 0.13 |
AIRLOOP F7 S1 | 0.19 | 0.19 | 0.13 | 0.13 |
AIRLOOP F7 S2 | 0.19 | 0.19 | 0.13 | 0.13 |
AIRLOOP F8 SW | 0.30 | 0.30 | 0.22 | 0.22 |
AIRLOOP F8 NW | 0.28 | 0.28 | 0.22 | 0.22 |
AIRLOOP F8 SE | 0.27 | 0.27 | 0.22 | 0.22 |
AIRLOOP F8 NE | 0.22 | 0.22 | 0.22 | 0.22 |
AIRLOOP F8 N1 | 0.15 | 0.15 | 0.13 | 0.13 |
AIRLOOP F8 N2 | 0.15 | 0.15 | 0.13 | 0.13 |
AIRLOOP F8 S1 | 0.19 | 0.19 | 0.13 | 0.13 |
AIRLOOP F8 S2 | 0.19 | 0.19 | 0.13 | 0.13 |
AIRLOOP F9 SW | 0.31 | 0.31 | 0.24 | 0.24 |
AIRLOOP F9 NW | 0.29 | 0.29 | 0.24 | 0.24 |
AIRLOOP F9 SE | 0.28 | 0.28 | 0.24 | 0.24 |
AIRLOOP F9 NE | 0.22 | 0.22 | 0.24 | 0.24 |
AIRLOOP F9 N1 | 0.16 | 0.16 | 0.14 | 0.14 |
AIRLOOP F9 N2 | 0.16 | 0.16 | 0.14 | 0.14 |
AIRLOOP F9 S1 | 0.20 | 0.20 | 0.14 | 0.14 |
AIRLOOP F9 S2 | 0.20 | 0.20 | 0.14 | 0.14 |
AIRLOOP T SW | 0.38 | 0.38 | 0.28 | 0.28 |
AIRLOOP T NW | 0.35 | 0.35 | 0.28 | 0.28 |
AIRLOOP T SE | 0.34 | 0.34 | 0.28 | 0.28 |
AIRLOOP T NE | 0.27 | 0.27 | 0.28 | 0.28 |
AIRLOOP T N1 | 0.21 | 0.21 | 0.19 | 0.19 |
AIRLOOP T N2 | 0.21 | 0.21 | 0.18 | 0.18 |
AIRLOOP T S1 | 0.27 | 0.27 | 0.18 | 0.18 |
AIRLOOP T S2 | 0.27 | 0.27 | 0.18 | 0.18 |
Report: System Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 3642.25 | 6467.50 | 1797.00 |
G NW APARTMENT | 3984.25 | 6837.25 | 2416.75 |
OFFICE | 1031.50 | 973.50 | 51.75 |
G NE APARTMENT | 3990.00 | 6793.75 | 2391.00 |
G N1 APARTMENT | 3175.00 | 7090.25 | 1874.00 |
G N2 APARTMENT | 3174.25 | 7085.25 | 1870.00 |
G S1 APARTMENT | 3002.50 | 6590.75 | 1315.25 |
G S2 APARTMENT | 3021.00 | 6523.00 | 1286.75 |
F2 SW APARTMENT | 3625.50 | 5477.00 | 1022.75 |
F2 NW APARTMENT | 3709.25 | 6046.25 | 1528.25 |
F2 SE APARTMENT | 3723.00 | 5190.25 | 892.75 |
F2 NE APARTMENT | 3747.00 | 6036.75 | 1519.00 |
F2 N1 APARTMENT | 2975.00 | 6250.00 | 1011.50 |
F2 N2 APARTMENT | 2975.50 | 6249.75 | 1007.50 |
F2 S1 APARTMENT | 3219.75 | 5488.50 | 717.00 |
F2 S2 APARTMENT | 3237.75 | 5445.25 | 708.25 |
F3 SW APARTMENT | 3651.75 | 5359.25 | 985.75 |
F3 NW APARTMENT | 3698.75 | 5967.50 | 1450.75 |
F3 SE APARTMENT | 3703.00 | 5304.25 | 949.75 |
F3 NE APARTMENT | 3724.75 | 5971.25 | 1448.75 |
F3 N1 APARTMENT | 2991.75 | 6116.50 | 933.50 |
F3 N2 APARTMENT | 2988.75 | 6118.25 | 930.50 |
F3 S1 APARTMENT | 3320.75 | 5229.25 | 673.00 |
F3 S2 APARTMENT | 3327.25 | 5213.75 | 670.75 |
F4 SW APARTMENT | 3684.75 | 5332.25 | 1005.75 |
F4 NW APARTMENT | 3741.00 | 5959.50 | 1486.75 |
F4 SE APARTMENT | 3716.50 | 5338.50 | 984.25 |
F4 NE APARTMENT | 3764.25 | 5964.75 | 1485.25 |
F4 N1 APARTMENT | 3025.00 | 6083.50 | 944.25 |
F4 N2 APARTMENT | 3023.75 | 6088.00 | 940.50 |
F4 S1 APARTMENT | 3385.50 | 5145.25 | 675.75 |
F4 S2 APARTMENT | 3386.00 | 5139.00 | 675.50 |
M SW APARTMENT | 3669.75 | 5365.50 | 1010.75 |
M NW APARTMENT | 3730.25 | 5982.00 | 1487.75 |
M SE APARTMENT | 3699.75 | 5375.00 | 985.25 |
M NE APARTMENT | 3745.00 | 5981.75 | 1480.25 |
M N1 APARTMENT | 3017.50 | 6073.00 | 928.50 |
M N2 APARTMENT | 3011.25 | 6084.75 | 924.75 |
M S1 APARTMENT | 3384.50 | 5154.75 | 669.00 |
M S2 APARTMENT | 3386.00 | 5155.50 | 669.75 |
F6 SW APARTMENT | 3627.00 | 5550.00 | 1088.00 |
F6 NW APARTMENT | 3765.50 | 6118.50 | 1626.25 |
F6 SE APARTMENT | 3662.75 | 5532.25 | 1055.50 |
F6 NE APARTMENT | 3761.00 | 6128.50 | 1597.50 |
F6 N1 APARTMENT | 2987.75 | 6215.75 | 1003.75 |
F6 N2 APARTMENT | 2983.75 | 6223.25 | 1002.50 |
F6 S1 APARTMENT | 3284.00 | 5334.75 | 709.75 |
F6 S2 APARTMENT | 3286.25 | 5333.50 | 710.50 |
F7 SW APARTMENT | 3601.25 | 5654.75 | 1135.00 |
F7 NW APARTMENT | 3770.25 | 6214.25 | 1693.75 |
F7 SE APARTMENT | 3629.50 | 5631.25 | 1104.25 |
F7 NE APARTMENT | 3775.75 | 6234.25 | 1671.75 |
F7 N1 APARTMENT | 2977.00 | 6321.25 | 1064.00 |
F7 N2 APARTMENT | 2975.00 | 6324.50 | 1063.75 |
F7 S1 APARTMENT | 3216.00 | 5466.00 | 739.50 |
F7 S2 APARTMENT | 3217.00 | 5463.25 | 739.25 |
F8 SW APARTMENT | 3585.25 | 5743.50 | 1181.25 |
F8 NW APARTMENT | 3784.75 | 6283.50 | 1752.75 |
F8 SE APARTMENT | 3605.25 | 5721.25 | 1152.25 |
F8 NE APARTMENT | 3799.00 | 6285.50 | 1732.25 |
F8 N1 APARTMENT | 2979.00 | 6390.25 | 1107.00 |
F8 N2 APARTMENT | 2979.75 | 6396.00 | 1108.50 |
F8 S1 APARTMENT | 3158.75 | 5589.00 | 765.00 |
F8 S2 APARTMENT | 3159.00 | 5590.00 | 765.00 |
F9 SW APARTMENT | 3660.50 | 5829.75 | 1306.50 |
F9 NW APARTMENT | 3901.75 | 6324.25 | 1891.00 |
F9 SE APARTMENT | 3676.25 | 5797.00 | 1273.25 |
F9 NE APARTMENT | 3917.00 | 6321.75 | 1865.75 |
F9 N1 APARTMENT | 3091.50 | 6454.00 | 1238.25 |
F9 N2 APARTMENT | 3090.75 | 6458.25 | 1235.50 |
F9 S1 APARTMENT | 3153.25 | 5715.25 | 823.75 |
F9 S2 APARTMENT | 3156.25 | 5716.50 | 824.75 |
T SW APARTMENT | 4582.75 | 6114.75 | 2422.50 |
T NW APARTMENT | 4826.00 | 6534.00 | 2948.25 |
T SE APARTMENT | 4619.25 | 6080.00 | 2393.75 |
T NE APARTMENT | 4855.00 | 6544.00 | 2944.25 |
T N1 APARTMENT | 4046.00 | 6641.50 | 2254.50 |
T N2 APARTMENT | 4045.75 | 6644.50 | 2253.50 |
T S1 APARTMENT | 3889.75 | 6031.25 | 1727.75 |
T S2 APARTMENT | 3895.25 | 6029.50 | 1728.75 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 5893.00 | 7239.25 | 3332.75 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 1.25 | 4.50 | 1.25 | 4.50 |
G NW APARTMENT | 1.25 | 6.75 | 1.25 | 6.75 |
OFFICE | 2.00 | 0.00 | 0.00 | 0.00 |
G NE APARTMENT | 2.00 | 5.25 | 2.00 | 5.25 |
G N1 APARTMENT | 3.50 | 10.50 | 3.50 | 10.50 |
G N2 APARTMENT | 4.25 | 9.00 | 4.25 | 9.00 |
G S1 APARTMENT | 1.50 | 9.75 | 1.50 | 9.75 |
G S2 APARTMENT | 1.75 | 7.00 | 1.75 | 7.00 |
F2 SW APARTMENT | 0.50 | 2.50 | 0.50 | 2.50 |
F2 NW APARTMENT | 0.00 | 4.25 | 0.00 | 4.25 |
F2 SE APARTMENT | 1.00 | 0.00 | 1.00 | 0.00 |
F2 NE APARTMENT | 0.50 | 52.25 | 0.50 | 52.25 |
F2 N1 APARTMENT | 3.00 | 30.00 | 3.00 | 30.00 |
F2 N2 APARTMENT | 3.50 | 33.00 | 3.50 | 33.00 |
F2 S1 APARTMENT | 3.50 | 6.75 | 3.50 | 6.75 |
F2 S2 APARTMENT | 3.50 | 4.25 | 3.50 | 4.25 |
F3 SW APARTMENT | 1.00 | 4.25 | 1.00 | 4.25 |
F3 NW APARTMENT | 0.50 | 6.00 | 0.50 | 6.00 |
F3 SE APARTMENT | 0.75 | 1.75 | 0.75 | 1.75 |
F3 NE APARTMENT | 0.75 | 59.75 | 0.75 | 59.75 |
F3 N1 APARTMENT | 3.75 | 39.75 | 3.75 | 39.75 |
F3 N2 APARTMENT | 3.75 | 45.25 | 3.75 | 45.25 |
F3 S1 APARTMENT | 3.25 | 10.25 | 3.25 | 10.25 |
F3 S2 APARTMENT | 3.25 | 8.25 | 3.25 | 8.25 |
F4 SW APARTMENT | 0.50 | 6.00 | 0.50 | 6.00 |
F4 NW APARTMENT | 0.00 | 7.75 | 0.00 | 7.75 |
F4 SE APARTMENT | 1.25 | 6.25 | 1.25 | 6.25 |
F4 NE APARTMENT | 0.00 | 65.00 | 0.00 | 65.00 |
F4 N1 APARTMENT | 3.00 | 43.50 | 3.00 | 43.50 |
F4 N2 APARTMENT | 4.00 | 48.25 | 4.00 | 48.25 |
F4 S1 APARTMENT | 3.00 | 12.75 | 3.00 | 12.75 |
F4 S2 APARTMENT | 3.50 | 12.00 | 3.50 | 12.00 |
M SW APARTMENT | 1.50 | 6.50 | 1.50 | 6.50 |
M NW APARTMENT | 0.00 | 8.75 | 0.00 | 8.75 |
M SE APARTMENT | 0.25 | 7.50 | 0.25 | 7.50 |
M NE APARTMENT | 0.25 | 69.25 | 0.25 | 69.25 |
M N1 APARTMENT | 3.25 | 45.50 | 3.25 | 45.50 |
M N2 APARTMENT | 2.50 | 50.75 | 2.50 | 50.75 |
M S1 APARTMENT | 2.50 | 14.25 | 2.50 | 14.25 |
M S2 APARTMENT | 2.50 | 12.00 | 2.50 | 12.00 |
F6 SW APARTMENT | 0.50 | 7.50 | 0.50 | 7.50 |
F6 NW APARTMENT | 0.00 | 10.25 | 0.00 | 10.25 |
F6 SE APARTMENT | 1.25 | 9.00 | 1.25 | 9.00 |
F6 NE APARTMENT | 0.25 | 70.75 | 0.25 | 70.75 |
F6 N1 APARTMENT | 2.25 | 47.00 | 2.25 | 47.00 |
F6 N2 APARTMENT | 2.50 | 53.25 | 2.50 | 53.25 |
F6 S1 APARTMENT | 2.75 | 16.50 | 2.75 | 16.50 |
F6 S2 APARTMENT | 2.25 | 15.00 | 2.25 | 15.00 |
F7 SW APARTMENT | 0.25 | 8.00 | 0.25 | 8.00 |
F7 NW APARTMENT | 0.25 | 10.50 | 0.25 | 10.50 |
F7 SE APARTMENT | 0.50 | 11.25 | 0.50 | 11.25 |
F7 NE APARTMENT | 0.00 | 72.75 | 0.00 | 72.75 |
F7 N1 APARTMENT | 1.50 | 48.50 | 1.50 | 48.50 |
F7 N2 APARTMENT | 2.00 | 55.00 | 2.00 | 55.00 |
F7 S1 APARTMENT | 3.00 | 17.75 | 3.00 | 17.75 |
F7 S2 APARTMENT | 3.25 | 17.00 | 3.25 | 17.00 |
F8 SW APARTMENT | 0.00 | 8.25 | 0.00 | 8.25 |
F8 NW APARTMENT | 0.00 | 11.00 | 0.00 | 11.00 |
F8 SE APARTMENT | 0.75 | 12.50 | 0.75 | 12.50 |
F8 NE APARTMENT | 0.00 | 59.75 | 0.00 | 59.75 |
F8 N1 APARTMENT | 2.25 | 50.00 | 2.25 | 50.00 |
F8 N2 APARTMENT | 1.75 | 56.00 | 1.75 | 56.00 |
F8 S1 APARTMENT | 3.75 | 19.25 | 3.75 | 19.25 |
F8 S2 APARTMENT | 3.00 | 18.50 | 3.00 | 18.50 |
F9 SW APARTMENT | 0.25 | 8.00 | 0.25 | 8.00 |
F9 NW APARTMENT | 0.00 | 10.75 | 0.00 | 10.75 |
F9 SE APARTMENT | 0.25 | 12.00 | 0.25 | 12.00 |
F9 NE APARTMENT | 0.00 | 30.75 | 0.00 | 30.75 |
F9 N1 APARTMENT | 3.25 | 43.25 | 3.25 | 43.25 |
F9 N2 APARTMENT | 2.25 | 47.25 | 2.25 | 47.25 |
F9 S1 APARTMENT | 1.00 | 17.75 | 1.00 | 17.75 |
F9 S2 APARTMENT | 1.50 | 16.00 | 1.50 | 16.00 |
T SW APARTMENT | 0.25 | 2.00 | 0.25 | 2.00 |
T NW APARTMENT | 0.00 | 7.25 | 0.00 | 7.25 |
T SE APARTMENT | 0.50 | 3.75 | 0.50 | 3.75 |
T NE APARTMENT | 0.00 | 32.25 | 0.00 | 32.25 |
T N1 APARTMENT | 0.50 | 31.50 | 0.50 | 31.50 |
T N2 APARTMENT | 0.00 | 32.50 | 0.00 | 32.50 |
T S1 APARTMENT | 0.75 | 1.75 | 0.75 | 1.75 |
T S2 APARTMENT | 0.25 | 2.00 | 0.25 | 2.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 97.25 | 99.50 | 95.50 | 99.50 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.207 | 0.000 | 0.300 |
G NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.207 | 0.000 | 0.296 |
OFFICE | 0.94 | 1.00 | 268.96 | 0.519 | 0.237 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.207 | 0.000 | 0.296 |
G N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.125 | 0.000 | 0.291 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.125 | 0.000 | 0.291 |
G S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.125 | 0.000 | 0.298 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.125 | 0.000 | 0.298 |
F2 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.297 | 0.000 | 0.355 |
F2 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.297 | 0.000 | 0.351 |
F2 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.297 | 0.000 | 0.357 |
F2 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.297 | 0.000 | 0.351 |
F2 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.179 | 0.000 | 0.348 |
F2 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.179 | 0.000 | 0.348 |
F2 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.179 | 0.000 | 0.354 |
F2 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.179 | 0.000 | 0.354 |
F3 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.352 | 0.000 | 0.394 |
F3 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.352 | 0.000 | 0.390 |
F3 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.352 | 0.000 | 0.394 |
F3 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.352 | 0.000 | 0.390 |
F3 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.212 | 0.000 | 0.387 |
F3 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.212 | 0.000 | 0.387 |
F3 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.212 | 0.000 | 0.392 |
F3 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.212 | 0.000 | 0.393 |
F4 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.393 | 0.000 | 0.404 |
F4 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.393 | 0.000 | 0.402 |
F4 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.393 | 0.000 | 0.405 |
F4 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.393 | 0.000 | 0.402 |
F4 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.237 | 0.000 | 0.399 |
F4 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.237 | 0.000 | 0.399 |
F4 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.237 | 0.000 | 0.404 |
F4 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.237 | 0.000 | 0.404 |
M SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.427 | 0.000 | 0.426 |
M NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.427 | 0.000 | 0.423 |
M SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.427 | 0.000 | 0.426 |
M NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.427 | 0.000 | 0.423 |
M N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.258 | 0.000 | 0.421 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.258 | 0.000 | 0.421 |
M S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.258 | 0.000 | 0.425 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.258 | 0.000 | 0.425 |
F6 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.457 | 0.000 | 0.444 |
F6 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.456 | 0.000 | 0.441 |
F6 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.457 | 0.000 | 0.445 |
F6 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.456 | 0.000 | 0.442 |
F6 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.275 | 0.000 | 0.439 |
F6 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.275 | 0.000 | 0.439 |
F6 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.276 | 0.000 | 0.443 |
F6 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.276 | 0.000 | 0.443 |
F7 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.483 | 0.000 | 0.460 |
F7 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.482 | 0.000 | 0.457 |
F7 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.483 | 0.000 | 0.460 |
F7 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.482 | 0.000 | 0.457 |
F7 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.291 | 0.000 | 0.455 |
F7 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.291 | 0.000 | 0.455 |
F7 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.291 | 0.000 | 0.459 |
F7 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.291 | 0.000 | 0.459 |
F8 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.506 | 0.000 | 0.476 |
F8 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.506 | 0.000 | 0.473 |
F8 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.506 | 0.000 | 0.477 |
F8 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.506 | 0.000 | 0.474 |
F8 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.305 | 0.000 | 0.471 |
F8 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.305 | 0.000 | 0.471 |
F8 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.305 | 0.000 | 0.475 |
F8 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.305 | 0.000 | 0.475 |
F9 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.527 | 0.000 | 0.492 |
F9 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.527 | 0.000 | 0.489 |
F9 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.527 | 0.000 | 0.492 |
F9 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.527 | 0.000 | 0.490 |
F9 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.318 | 0.000 | 0.487 |
F9 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.318 | 0.000 | 0.487 |
F9 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.318 | 0.000 | 0.491 |
F9 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.318 | 0.000 | 0.491 |
T SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.547 | 0.000 | 0.501 |
T NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.547 | 0.000 | 0.499 |
T SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.547 | 0.000 | 0.502 |
T NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.547 | 0.000 | 0.500 |
T N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.330 | 0.000 | 0.497 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.330 | 0.000 | 0.497 |
T S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.330 | 0.000 | 0.501 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.330 | 0.000 | 0.501 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.96 | 0.501 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
F2 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F2 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F2 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F2 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F2 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F2 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
F2 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F2 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
F3 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F3 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F3 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F3 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F3 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F3 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
F3 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F3 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
F4 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F4 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F4 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F4 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F4 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F4 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
F4 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F4 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
F6 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F6 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F6 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F6 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F6 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F6 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
F6 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F6 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
F7 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F7 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F7 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F7 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F7 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F7 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
F7 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F7 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
F8 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F8 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F8 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F8 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F8 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F8 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
F8 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F8 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
F9 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F9 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F9 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F9 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F9 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F9 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
F9 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
F9 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.340 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Surfaces by ClassTotal | Outdoors | |
Wall | 420 | 140 |
Floor | 90 | 9 |
Roof | 90 | 9 |
Internal Mass | 80 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 140 | 140 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 80 |
Conditioned Zones | 80 |
Unconditioned Zones | 10 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 4156 |
Defaulted Fields | 814 |
Fields with Defaults | 11184 |
Autosized Fields | 1293 |
Autosizable Fields | 1630 |
Autocalculated Fields | 907 |
Autocalculatable Fields | 1710 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 3121.23 | 55408.02 | 04-MAY-05:00 | 225073.24 | 26-JAN-23:00 |
Electricity:Building | 1433.88 | 25760.85 | 01-JAN-03:15 | 70162.48 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity | 296.56 | 6715.87 | 01-JAN-00:15 | 14401.37 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 242.55 | 5824.91 | 01-JAN-00:15 | 11484.27 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 39.38 | 663.42 | 01-JAN-00:15 | 2934.49 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 29.88 | 469.18 | 01-JAN-00:15 | 2345.88 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F2 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F2 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F3 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F3 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F4 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F4 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:M SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M CORRIDOR | 32.88 | 1042.61 | 01-JAN-00:15 | 1042.61 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 32.88 | 1042.61 | 01-JAN-00:15 | 1042.61 | 01-JAN-00:15 |
Electricity:Zone:F6 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F6 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F7 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F7 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F8 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F8 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F9 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F9 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:T SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T CORRIDOR | 179.47 | 1701.70 | 01-JAN-00:15 | 10868.20 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 54.01 | 890.97 | 01-JAN-00:15 | 2917.11 | 01-JAN-19:15 |
InteriorEquipment:Electricity | 1137.32 | 19044.98 | 01-JAN-03:15 | 57142.09 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 1137.32 | 19044.98 | 01-JAN-03:15 | 57142.09 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 9.50 | 194.24 | 01-JAN-00:15 | 588.62 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T CORRIDOR | 163.03 | 1180.40 | 01-JAN-00:15 | 10346.90 | 01-JAN-07:15 |
Fans:Electricity | 652.60 | 20693.73 | 01-JAN-00:15 | 20693.73 | 01-JAN-00:15 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Electricity:HVAC | 1432.25 | 21354.97 | 06-MAY-02:30 | 174193.81 | 27-JAN-01:00 |
ElectricityProduced:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityProduced:HVAC | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricityProduced | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 3121.23 | 55408.02 | 04-MAY-05:00 | 225073.24 | 26-JAN-23:00 |
ElectricityPurchased:Plant | 3121.23 | 55408.02 | 04-MAY-05:00 | 225073.24 | 26-JAN-23:00 |
Cogeneration:ElectricityPurchased | 3121.23 | 55408.02 | 04-MAY-05:00 | 225073.24 | 26-JAN-23:00 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 3121.23 | 55408.02 | 04-MAY-05:00 | 225073.24 | 26-JAN-23:00 |
ElectricityNet:Plant | 3121.23 | 55408.02 | 04-MAY-05:00 | 225073.24 | 26-JAN-23:00 |
Cogeneration:ElectricityNet | 3121.23 | 55408.02 | 04-MAY-05:00 | 225073.24 | 26-JAN-23:00 |
ExteriorLights:Electricity | 162.68 | 0.00 | 01-JAN-07:30 | 10364.00 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 162.68 | 0.00 | 01-JAN-07:30 | 10364.00 | 01-JAN-00:15 |
General:Fans:Electricity | 652.60 | 20693.73 | 01-JAN-00:15 | 20693.73 | 01-JAN-00:15 |
Cooling:Electricity | 382.22 | 0.00 | 01-JAN-00:15 | 88567.13 | 19-JUL-17:00 |
Heating:Electricity | 361.26 | 0.00 | 10-MAR-15:45 | 152757.45 | 27-JAN-01:00 |
Electricity:Plant | 92.42 | 36.93 | 10-MAR-17:15 | 6030.51 | 08-JUN-12:15 |
HeatRejection:Electricity | 17.81 | 0.00 | 01-JAN-00:15 | 3607.28 | 08-JUN-12:15 |
Boiler Parasitic:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Pumps:Electricity | 74.60 | 36.93 | 10-MAR-17:15 | 2423.23 | 01-JAN-00:15 |
WIRED_LTG_ELECTRICITY | 0.44 | 0.00 | 01-JAN-00:15 | 21.60 | 01-JAN-19:30 |
WIRED_INT_EQUIP | 979.40 | 1018.50 | 01-JAN-00:15 | 10185.00 | 01-JAN-07:15 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 2533.28 | 2357.00 | 12-FEB-00:15 | 442243.97 | 27-JAN-07:30 |
Gas:Plant | 2533.28 | 2357.00 | 12-FEB-00:15 | 442243.97 | 27-JAN-07:30 |
WaterSystems:Gas | 1177.88 | 2357.00 | 01-JAN-00:15 | 83631.21 | 09-FEB-08:00 |
Water Heater:WaterSystems:Gas | 1177.88 | 2357.00 | 01-JAN-00:15 | 83631.21 | 09-FEB-08:00 |
Heating:Gas | 1355.40 | 0.00 | 11-FEB-13:15 | 362300.75 | 27-JAN-01:30 |
Boiler:Heating:Gas | 1355.40 | 0.00 | 11-FEB-13:15 | 362300.75 | 27-JAN-01:30 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
PlantLoopCoolingDemand:Facility | 1664.44 | 0.00 | 01-JAN-00:15 | 426244.21 | 22-AUG-13:45 |
PlantLoopCoolingDemand:HVAC | 1664.44 | 0.00 | 01-JAN-00:15 | 426244.21 | 22-AUG-13:45 |
CoolingCoils:PlantLoopCoolingDemand | 1664.44 | 0.00 | 01-JAN-00:15 | 426244.21 | 22-AUG-13:45 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 5865.14 | 0.00 | 01-JAN-02:15 | 0.00 | 17-JUL-17:15 |
Water:Plant | 5865.14 | 0.00 | 01-JAN-02:15 | 0.00 | 17-JUL-17:15 |
WaterSystems:Water | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:Water | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
MainsWater:Facility | 5865.14 | 0.00 | 01-JAN-02:15 | 0.00 | 17-JUL-17:15 |
MainsWater:Plant | 5865.14 | 0.00 | 01-JAN-02:15 | 0.00 | 17-JUL-17:15 |
WaterSystems:MainsWater | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:MainsWater | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
sub cat:WaterSystems:Water | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
sub cat:WaterSystems:MainsWater | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
HeatRejection:Water | 1086.63 | 0.00 | 01-JAN-00:15 | 0.00 | 19-JUL-15:00 |
HeatRejection:MainsWater | 1086.63 | 0.00 | 01-JAN-00:15 | 0.00 | 19-JUL-15:00 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 1976.34 | 465.63 | 13-AUG-01:15 | 334770.41 | 27-JAN-07:15 |
PlantLoopHeatingDemand:Plant | 916.94 | 465.63 | 13-AUG-01:15 | 63279.87 | 12-FEB-07:30 |
WaterSystems:PlantLoopHeatingDemand | 916.94 | 465.63 | 13-AUG-01:15 | 63279.87 | 12-FEB-07:30 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 6398.62 | 5348.40 | 02-NOV-01:45 | 1052703.01 | 26-JAN-23:00 |
EnergyTransfer:Building | 1773.62 | 3619.66 | 03-NOV-21:15 | 343315.10 | 27-JAN-01:00 |
EnergyTransfer:Zone:G SW APARTMENT | 18.83 | 0.02 | 28-MAR-01:00 | 3473.91 | 27-JAN-01:00 |
Heating:EnergyTransfer | 947.16 | 0.00 | 11-FEB-16:30 | 343315.10 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 10.78 | 0.00 | 05-JAN-14:00 | 3473.91 | 27-JAN-01:00 |
Cooling:EnergyTransfer | 826.45 | 0.00 | 01-JAN-00:15 | 187218.09 | 19-JUL-14:45 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 8.05 | 0.00 | 01-JAN-00:15 | 2600.71 | 05-SEP-15:15 |
EnergyTransfer:Zone:G NW APARTMENT | 20.30 | 0.03 | 03-OCT-02:30 | 3678.49 | 27-JAN-08:15 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 14.35 | 0.00 | 11-FEB-14:00 | 3678.49 | 27-JAN-08:15 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 5.95 | 0.00 | 01-JAN-00:15 | 2261.77 | 25-JUL-17:15 |
EnergyTransfer:Zone:OFFICE | 24.84 | 0.05 | 10-OCT-02:45 | 3729.16 | 05-SEP-13:30 |
Heating:EnergyTransfer:Zone:OFFICE | 8.28 | 0.00 | 02-JAN-09:15 | 3352.48 | 26-JAN-23:00 |
Cooling:EnergyTransfer:Zone:OFFICE | 16.56 | 0.00 | 01-JAN-00:15 | 3729.16 | 05-SEP-13:30 |
EnergyTransfer:Zone:G NE APARTMENT | 20.14 | 0.01 | 21-OCT-02:45 | 3529.60 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 14.14 | 0.00 | 11-FEB-16:30 | 3529.60 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 6.00 | 0.00 | 01-JAN-00:15 | 1779.23 | 15-JUN-08:45 |
EnergyTransfer:Zone:G N1 APARTMENT | 12.99 | 0.02 | 14-AUG-20:15 | 2373.82 | 27-JAN-08:15 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 8.33 | 0.00 | 11-FEB-15:30 | 2373.82 | 27-JAN-08:15 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 4.66 | 0.00 | 01-JAN-00:15 | 1231.81 | 25-JUL-17:15 |
EnergyTransfer:Zone:G N2 APARTMENT | 12.99 | 0.01 | 03-OCT-12:30 | 2368.75 | 27-JAN-08:15 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 8.33 | 0.00 | 11-FEB-16:15 | 2368.75 | 27-JAN-08:15 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 4.66 | 0.00 | 01-JAN-00:15 | 1232.09 | 25-JUL-17:15 |
EnergyTransfer:Zone:G S1 APARTMENT | 12.17 | 0.00 | 02-JUL-07:00 | 2082.00 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 4.95 | 0.00 | 01-JAN-10:30 | 2082.00 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 7.22 | 0.00 | 01-JAN-00:15 | 1869.82 | 30-AUG-13:15 |
EnergyTransfer:Zone:G S2 APARTMENT | 12.20 | 0.00 | 08-SEP-09:00 | 2066.55 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 4.75 | 0.00 | 01-JAN-10:30 | 2066.55 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 7.45 | 0.00 | 01-JAN-00:15 | 1922.57 | 30-AUG-13:15 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F2 SW APARTMENT | 22.94 | 0.01 | 06-NOV-18:45 | 4176.15 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F2 SW APARTMENT | 9.94 | 0.00 | 01-JAN-17:15 | 4176.15 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT | 12.99 | 0.00 | 01-JAN-00:15 | 3304.13 | 05-SEP-15:15 |
EnergyTransfer:Zone:F2 NW APARTMENT | 23.82 | 0.02 | 10-MAR-20:15 | 4279.21 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F2 NW APARTMENT | 14.26 | 0.00 | 11-FEB-13:30 | 4279.21 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT | 9.56 | 0.00 | 01-JAN-00:15 | 2935.66 | 25-JUL-17:15 |
EnergyTransfer:Zone:F2 SE APARTMENT | 23.32 | 0.03 | 05-OCT-01:00 | 4100.81 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F2 SE APARTMENT | 9.00 | 0.00 | 01-JAN-17:00 | 4100.81 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT | 14.32 | 0.00 | 01-JAN-00:15 | 3177.30 | 28-SEP-12:30 |
EnergyTransfer:Zone:F2 NE APARTMENT | 23.72 | 0.03 | 26-MAR-08:45 | 4290.80 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F2 NE APARTMENT | 13.98 | 0.00 | 11-FEB-14:15 | 4290.80 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT | 9.75 | 0.00 | 01-JAN-00:15 | 2293.25 | 16-JUN-08:45 |
EnergyTransfer:Zone:F2 N1 APARTMENT | 14.30 | 0.00 | 18-JUN-17:45 | 2486.09 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT | 6.67 | 0.00 | 16-JAN-19:00 | 2486.09 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT | 7.63 | 0.00 | 01-JAN-00:15 | 1689.53 | 28-JUN-18:15 |
EnergyTransfer:Zone:F2 N2 APARTMENT | 14.31 | 0.03 | 09-MAY-13:15 | 2487.41 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT | 6.67 | 0.00 | 16-JAN-19:00 | 2487.41 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT | 7.64 | 0.00 | 01-JAN-00:15 | 1681.44 | 28-JUN-18:15 |
EnergyTransfer:Zone:F2 S1 APARTMENT | 15.25 | 0.10 | 03-SEP-20:30 | 2392.21 | 30-AUG-13:15 |
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT | 3.50 | 0.00 | 01-JAN-09:30 | 2375.60 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT | 11.74 | 0.00 | 01-JAN-00:15 | 2392.21 | 30-AUG-13:15 |
EnergyTransfer:Zone:F2 S2 APARTMENT | 15.32 | 0.06 | 11-AUG-05:45 | 2409.19 | 30-AUG-13:15 |
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT | 3.46 | 0.00 | 01-JAN-09:30 | 2370.34 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT | 11.85 | 0.00 | 01-JAN-00:15 | 2409.19 | 30-AUG-13:15 |
EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F3 SW APARTMENT | 24.10 | 0.01 | 16-OCT-11:45 | 4577.48 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F3 SW APARTMENT | 10.59 | 0.00 | 01-JAN-17:00 | 4577.48 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT | 13.50 | 0.00 | 01-JAN-00:15 | 3368.82 | 16-APR-14:30 |
EnergyTransfer:Zone:F3 NW APARTMENT | 25.09 | 0.00 | 27-MAR-20:15 | 4688.62 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F3 NW APARTMENT | 15.02 | 0.00 | 11-FEB-13:30 | 4688.62 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT | 10.07 | 0.00 | 01-JAN-00:15 | 2991.81 | 25-JUL-17:15 |
EnergyTransfer:Zone:F3 SE APARTMENT | 24.14 | 0.08 | 27-MAR-23:30 | 4574.25 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F3 SE APARTMENT | 10.28 | 0.00 | 01-JAN-17:00 | 4574.25 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT | 13.85 | 0.00 | 01-JAN-00:15 | 3149.05 | 16-APR-13:15 |
EnergyTransfer:Zone:F3 NE APARTMENT | 24.99 | 0.03 | 12-OCT-01:30 | 4697.50 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F3 NE APARTMENT | 14.74 | 0.00 | 11-FEB-14:15 | 4697.50 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT | 10.25 | 0.00 | 01-JAN-00:15 | 2411.49 | 16-JUN-09:00 |
EnergyTransfer:Zone:F3 N1 APARTMENT | 15.01 | 0.03 | 09-SEP-20:45 | 2691.34 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT | 6.76 | 0.00 | 01-JAN-17:15 | 2691.34 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT | 8.25 | 0.00 | 01-JAN-00:15 | 1852.05 | 20-JUL-18:00 |
EnergyTransfer:Zone:F3 N2 APARTMENT | 15.02 | 0.01 | 12-APR-00:15 | 2692.61 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT | 6.76 | 0.00 | 01-JAN-17:15 | 2692.61 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT | 8.26 | 0.00 | 01-JAN-00:15 | 1847.12 | 20-JUL-18:00 |
EnergyTransfer:Zone:F3 S1 APARTMENT | 16.10 | 0.06 | 24-JUN-08:30 | 2568.18 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT | 3.57 | 0.00 | 01-JAN-09:30 | 2568.18 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT | 12.53 | 0.00 | 01-JAN-00:15 | 2551.36 | 26-SEP-13:00 |
EnergyTransfer:Zone:F3 S2 APARTMENT | 16.13 | 0.04 | 06-AUG-18:15 | 2568.29 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT | 3.56 | 0.00 | 01-JAN-09:30 | 2568.29 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT | 12.57 | 0.00 | 01-JAN-00:15 | 2561.84 | 26-SEP-13:00 |
EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F4 SW APARTMENT | 25.04 | 0.04 | 01-MAY-08:30 | 4947.41 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F4 SW APARTMENT | 11.58 | 0.00 | 01-JAN-17:00 | 4947.41 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT | 13.47 | 0.00 | 01-JAN-00:15 | 3415.84 | 16-APR-14:30 |
EnergyTransfer:Zone:F4 NW APARTMENT | 26.20 | 0.00 | 11-OCT-03:15 | 5062.48 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F4 NW APARTMENT | 16.10 | 0.00 | 11-FEB-13:45 | 5062.48 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT | 10.10 | 0.00 | 01-JAN-00:15 | 3018.36 | 25-JUL-17:15 |
EnergyTransfer:Zone:F4 SE APARTMENT | 25.04 | 0.02 | 10-APR-19:00 | 4953.00 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F4 SE APARTMENT | 11.38 | 0.00 | 01-JAN-17:00 | 4953.00 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT | 13.67 | 0.00 | 01-JAN-00:15 | 3192.39 | 16-APR-13:15 |
EnergyTransfer:Zone:F4 NE APARTMENT | 26.07 | 0.00 | 12-OCT-01:45 | 5069.35 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F4 NE APARTMENT | 15.79 | 0.00 | 11-FEB-14:30 | 5069.35 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT | 10.28 | 0.00 | 01-JAN-00:15 | 2442.13 | 16-JUN-09:00 |
EnergyTransfer:Zone:F4 N1 APARTMENT | 15.59 | 0.00 | 18-JUN-10:45 | 2907.80 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT | 7.25 | 0.00 | 01-JAN-17:15 | 2907.80 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT | 8.35 | 0.00 | 01-JAN-00:15 | 1893.21 | 20-JUL-18:00 |
EnergyTransfer:Zone:F4 N2 APARTMENT | 15.59 | 0.04 | 13-SEP-08:45 | 2909.04 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT | 7.24 | 0.00 | 01-JAN-17:15 | 2909.04 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT | 8.35 | 0.00 | 01-JAN-00:15 | 1888.63 | 20-JUL-18:00 |
EnergyTransfer:Zone:F4 S1 APARTMENT | 16.57 | 0.00 | 12-MAY-13:15 | 2778.93 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT | 3.97 | 0.00 | 01-JAN-10:15 | 2778.93 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT | 12.59 | 0.00 | 01-JAN-00:15 | 2610.44 | 26-SEP-13:00 |
EnergyTransfer:Zone:F4 S2 APARTMENT | 16.58 | 0.00 | 30-JUL-05:45 | 2780.11 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT | 3.97 | 0.00 | 01-JAN-10:30 | 2780.11 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT | 12.61 | 0.00 | 01-JAN-00:15 | 2618.96 | 26-SEP-13:00 |
EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M SW APARTMENT | 25.88 | 0.03 | 18-JUN-04:30 | 5245.21 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 12.40 | 0.00 | 01-JAN-17:00 | 5245.21 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 13.47 | 0.00 | 01-JAN-00:15 | 3464.06 | 16-APR-14:30 |
EnergyTransfer:Zone:M NW APARTMENT | 27.17 | 0.02 | 03-OCT-09:45 | 5360.95 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 16.96 | 0.00 | 11-FEB-13:45 | 5360.95 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 10.21 | 0.00 | 01-JAN-00:15 | 3062.09 | 25-JUL-17:15 |
EnergyTransfer:Zone:M SE APARTMENT | 25.85 | 0.00 | 16-AUG-20:30 | 5250.66 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 12.21 | 0.00 | 01-JAN-17:00 | 5250.66 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 13.64 | 0.00 | 01-JAN-00:15 | 3239.00 | 16-APR-13:15 |
EnergyTransfer:Zone:M NE APARTMENT | 27.01 | 0.06 | 19-OCT-12:30 | 5366.37 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 16.64 | 0.00 | 11-FEB-14:45 | 5366.37 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 10.37 | 0.00 | 01-JAN-00:15 | 2487.72 | 16-JUN-09:00 |
EnergyTransfer:Zone:M N1 APARTMENT | 16.12 | 0.00 | 01-MAY-17:00 | 3078.57 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 7.64 | 0.00 | 01-JAN-17:15 | 3078.57 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 8.49 | 0.00 | 01-JAN-00:15 | 1945.24 | 20-JUL-18:00 |
EnergyTransfer:Zone:M N2 APARTMENT | 16.13 | 0.05 | 28-MAY-20:45 | 3079.77 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 7.63 | 0.00 | 01-JAN-17:15 | 3079.77 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 8.49 | 0.00 | 01-JAN-00:15 | 1940.81 | 20-JUL-18:00 |
EnergyTransfer:Zone:M S1 APARTMENT | 16.95 | 0.28 | 29-SEP-09:15 | 2948.72 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 4.31 | 0.00 | 01-JAN-10:15 | 2948.72 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 12.64 | 0.00 | 01-JAN-00:15 | 2659.70 | 26-SEP-13:00 |
EnergyTransfer:Zone:M S2 APARTMENT | 16.96 | 0.07 | 20-NOV-16:15 | 2950.06 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 4.31 | 0.00 | 01-JAN-10:15 | 2950.06 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 12.65 | 0.00 | 01-JAN-00:15 | 2667.83 | 26-SEP-13:00 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F6 SW APARTMENT | 26.50 | 0.04 | 18-JUN-04:45 | 5556.25 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F6 SW APARTMENT | 13.69 | 0.00 | 01-JAN-17:00 | 5556.25 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT | 12.81 | 0.00 | 01-JAN-00:15 | 3446.36 | 16-APR-14:30 |
EnergyTransfer:Zone:F6 NW APARTMENT | 28.16 | 0.02 | 13-JUN-02:15 | 5673.06 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F6 NW APARTMENT | 18.42 | 0.00 | 11-FEB-14:00 | 5673.06 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT | 9.74 | 0.00 | 01-JAN-00:15 | 3039.55 | 25-JUL-17:15 |
EnergyTransfer:Zone:F6 SE APARTMENT | 26.44 | 0.02 | 05-OCT-02:15 | 5560.56 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F6 SE APARTMENT | 13.48 | 0.00 | 01-JAN-17:00 | 5560.56 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT | 12.96 | 0.00 | 01-JAN-00:15 | 3220.73 | 16-APR-13:15 |
EnergyTransfer:Zone:F6 NE APARTMENT | 27.96 | 0.02 | 28-MAR-16:45 | 5677.30 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F6 NE APARTMENT | 18.08 | 0.00 | 11-FEB-15:15 | 5677.30 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT | 9.88 | 0.00 | 01-JAN-00:15 | 2470.40 | 16-JUN-09:00 |
EnergyTransfer:Zone:F6 N1 APARTMENT | 16.57 | 0.00 | 08-JUN-20:30 | 3278.91 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT | 8.56 | 0.00 | 01-JAN-17:15 | 3278.91 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT | 8.01 | 0.00 | 01-JAN-00:15 | 1936.21 | 20-JUL-18:00 |
EnergyTransfer:Zone:F6 N2 APARTMENT | 16.57 | 0.00 | 08-NOV-15:30 | 3280.05 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT | 8.55 | 0.00 | 01-JAN-17:15 | 3280.05 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT | 8.02 | 0.00 | 01-JAN-00:15 | 1928.46 | 20-JUL-18:00 |
EnergyTransfer:Zone:F6 S1 APARTMENT | 16.89 | 0.05 | 30-SEP-12:15 | 3148.22 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT | 4.99 | 0.00 | 01-JAN-10:30 | 3148.22 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT | 11.90 | 0.00 | 01-JAN-00:15 | 2632.10 | 26-SEP-13:00 |
EnergyTransfer:Zone:F6 S2 APARTMENT | 16.90 | 0.12 | 13-APR-13:45 | 3149.54 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT | 5.00 | 0.00 | 01-JAN-10:30 | 3149.54 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT | 11.90 | 0.00 | 01-JAN-00:15 | 2640.12 | 26-SEP-13:00 |
EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F7 SW APARTMENT | 27.17 | 0.02 | 19-MAR-12:15 | 5817.85 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F7 SW APARTMENT | 14.74 | 0.00 | 01-JAN-17:15 | 5817.85 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT | 12.43 | 0.00 | 01-JAN-00:15 | 3447.40 | 16-APR-14:30 |
EnergyTransfer:Zone:F7 NW APARTMENT | 29.05 | 0.03 | 19-APR-13:00 | 5934.07 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F7 NW APARTMENT | 19.57 | 0.00 | 11-FEB-15:30 | 5934.07 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT | 9.49 | 0.00 | 01-JAN-00:15 | 3039.23 | 25-JUL-17:15 |
EnergyTransfer:Zone:F7 SE APARTMENT | 27.08 | 0.00 | 05-NOV-23:15 | 5821.05 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F7 SE APARTMENT | 14.52 | 0.00 | 01-JAN-17:00 | 5821.05 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT | 12.56 | 0.00 | 01-JAN-00:15 | 3221.81 | 16-APR-13:15 |
EnergyTransfer:Zone:F7 NE APARTMENT | 28.82 | 0.01 | 10-OCT-00:15 | 5937.30 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F7 NE APARTMENT | 19.21 | 0.00 | 11-FEB-16:00 | 5937.30 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT | 9.62 | 0.00 | 01-JAN-00:15 | 2473.45 | 16-JUN-09:00 |
EnergyTransfer:Zone:F7 N1 APARTMENT | 17.01 | 0.03 | 21-MAY-20:15 | 3442.44 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT | 9.26 | 0.00 | 01-JAN-17:15 | 3442.44 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT | 7.76 | 0.00 | 01-JAN-00:15 | 1944.84 | 20-JUL-18:00 |
EnergyTransfer:Zone:F7 N2 APARTMENT | 17.02 | 0.05 | 01-JUL-14:30 | 3443.55 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT | 9.26 | 0.00 | 01-JAN-17:15 | 3443.55 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT | 7.76 | 0.00 | 01-JAN-00:15 | 1932.51 | 20-JUL-18:00 |
EnergyTransfer:Zone:F7 S1 APARTMENT | 17.01 | 0.01 | 13-FEB-17:30 | 3313.50 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT | 5.56 | 0.00 | 01-JAN-10:45 | 3313.50 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT | 11.45 | 0.00 | 01-JAN-00:15 | 2618.00 | 26-SEP-13:00 |
EnergyTransfer:Zone:F7 S2 APARTMENT | 17.01 | 0.02 | 16-AUG-20:15 | 3314.77 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT | 5.56 | 0.00 | 01-JAN-10:45 | 3314.77 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT | 11.45 | 0.00 | 01-JAN-00:15 | 2626.07 | 26-SEP-13:00 |
EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F8 SW APARTMENT | 27.94 | 0.02 | 19-SEP-23:30 | 6062.05 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F8 SW APARTMENT | 15.77 | 0.00 | 01-JAN-17:15 | 6062.05 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT | 12.17 | 0.00 | 01-JAN-00:15 | 3458.96 | 16-APR-14:30 |
EnergyTransfer:Zone:F8 NW APARTMENT | 30.01 | 0.00 | 11-FEB-15:30 | 6176.84 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F8 NW APARTMENT | 20.67 | 0.00 | 11-FEB-15:45 | 6176.84 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT | 9.34 | 0.00 | 01-JAN-00:15 | 3051.68 | 25-JUL-17:15 |
EnergyTransfer:Zone:F8 SE APARTMENT | 27.82 | 0.00 | 05-NOV-12:15 | 6064.25 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F8 SE APARTMENT | 15.53 | 0.00 | 01-JAN-17:00 | 6064.25 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT | 12.29 | 0.00 | 01-JAN-00:15 | 3236.81 | 16-APR-13:15 |
EnergyTransfer:Zone:F8 NE APARTMENT | 29.77 | 0.10 | 28-OCT-13:30 | 6179.17 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F8 NE APARTMENT | 20.31 | 0.00 | 11-FEB-16:15 | 6179.17 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT | 9.46 | 0.00 | 01-JAN-00:15 | 2545.04 | 16-JUN-09:00 |
EnergyTransfer:Zone:F8 N1 APARTMENT | 17.57 | 0.07 | 04-APR-23:15 | 3597.53 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT | 9.97 | 0.00 | 01-JAN-17:15 | 3597.53 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT | 7.61 | 0.00 | 01-JAN-00:15 | 1962.47 | 20-JUL-18:00 |
EnergyTransfer:Zone:F8 N2 APARTMENT | 17.57 | 0.04 | 22-OCT-01:45 | 3598.58 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT | 9.96 | 0.00 | 01-JAN-17:15 | 3598.58 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT | 7.61 | 0.00 | 01-JAN-00:15 | 1949.34 | 20-JUL-18:00 |
EnergyTransfer:Zone:F8 S1 APARTMENT | 17.27 | 0.02 | 13-OCT-14:00 | 3471.66 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT | 6.14 | 0.00 | 01-JAN-11:15 | 3471.66 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT | 11.13 | 0.00 | 01-JAN-00:15 | 2597.42 | 26-SEP-13:00 |
EnergyTransfer:Zone:F8 S2 APARTMENT | 17.27 | 0.06 | 10-FEB-00:30 | 3472.85 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT | 6.14 | 0.00 | 01-JAN-11:00 | 3472.85 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT | 11.13 | 0.00 | 01-JAN-00:15 | 2605.62 | 26-SEP-13:00 |
EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F9 SW APARTMENT | 29.66 | 0.02 | 08-AUG-01:00 | 6408.44 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F9 SW APARTMENT | 17.54 | 0.00 | 01-JAN-17:15 | 6408.44 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT | 12.12 | 0.00 | 01-JAN-00:15 | 3527.84 | 16-APR-14:30 |
EnergyTransfer:Zone:F9 NW APARTMENT | 31.99 | 0.02 | 23-SEP-03:00 | 6518.16 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F9 NW APARTMENT | 22.56 | 0.00 | 11-FEB-16:00 | 6518.16 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT | 9.42 | 0.00 | 01-JAN-00:15 | 3154.43 | 25-JUL-17:15 |
EnergyTransfer:Zone:F9 SE APARTMENT | 29.46 | 0.01 | 22-JUN-22:30 | 6409.33 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F9 SE APARTMENT | 17.26 | 0.00 | 01-JAN-17:15 | 6409.33 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT | 12.20 | 0.00 | 01-JAN-00:15 | 3300.65 | 16-APR-13:15 |
EnergyTransfer:Zone:F9 NE APARTMENT | 31.70 | 0.01 | 29-MAR-14:30 | 6519.33 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F9 NE APARTMENT | 22.19 | 0.00 | 11-FEB-16:15 | 6519.33 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT | 9.51 | 0.00 | 01-JAN-00:15 | 2692.65 | 16-JUN-09:00 |
EnergyTransfer:Zone:F9 N1 APARTMENT | 19.02 | 0.02 | 09-NOV-05:00 | 3848.06 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT | 11.40 | 0.00 | 10-FEB-18:15 | 3848.06 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT | 7.62 | 0.00 | 01-JAN-00:15 | 2071.91 | 20-JUL-17:45 |
EnergyTransfer:Zone:F9 N2 APARTMENT | 19.02 | 0.03 | 10-AUG-05:45 | 3849.05 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT | 11.39 | 0.00 | 10-FEB-18:15 | 3849.05 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT | 7.63 | 0.00 | 01-JAN-00:15 | 2058.18 | 20-JUL-17:45 |
EnergyTransfer:Zone:F9 S1 APARTMENT | 18.21 | 0.06 | 19-JUN-03:30 | 3729.20 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT | 7.30 | 0.00 | 01-JAN-16:15 | 3729.20 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT | 10.91 | 0.00 | 01-JAN-00:15 | 2522.01 | 26-SEP-13:00 |
EnergyTransfer:Zone:F9 S2 APARTMENT | 18.22 | 0.03 | 26-NOV-11:45 | 3730.29 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT | 7.30 | 0.00 | 01-JAN-16:15 | 3730.29 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT | 10.92 | 0.00 | 01-JAN-00:15 | 2532.06 | 26-SEP-13:00 |
EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:T SW APARTMENT | 37.19 | 0.01 | 27-SEP-01:45 | 7429.17 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 24.48 | 0.00 | 10-JAN-11:00 | 7429.17 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 12.71 | 0.00 | 01-JAN-00:15 | 4117.05 | 16-APR-14:15 |
EnergyTransfer:Zone:T NW APARTMENT | 38.86 | 0.06 | 09-SEP-03:15 | 7503.13 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 28.78 | 0.00 | 11-FEB-16:15 | 7503.13 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 10.08 | 0.00 | 01-JAN-00:15 | 3714.01 | 19-JUL-14:45 |
EnergyTransfer:Zone:T SE APARTMENT | 36.65 | 0.02 | 22-MAY-00:30 | 7417.36 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 24.07 | 0.00 | 10-JAN-10:30 | 7417.36 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 12.58 | 0.00 | 01-JAN-00:15 | 3822.44 | 05-SEP-12:00 |
EnergyTransfer:Zone:T NE APARTMENT | 38.18 | 0.00 | 27-MAR-19:30 | 7491.43 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 28.22 | 0.00 | 11-FEB-16:15 | 7491.43 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 9.96 | 0.00 | 01-JAN-00:15 | 3113.01 | 16-JUN-09:00 |
EnergyTransfer:Zone:T N1 APARTMENT | 24.82 | 0.02 | 23-FEB-15:00 | 4770.68 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 16.85 | 0.00 | 11-FEB-13:00 | 4770.68 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 7.97 | 0.00 | 01-JAN-00:15 | 2354.51 | 20-JUL-17:45 |
EnergyTransfer:Zone:T N2 APARTMENT | 24.82 | 0.01 | 26-MAR-12:15 | 4770.95 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 16.85 | 0.00 | 11-FEB-13:00 | 4770.95 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 7.97 | 0.00 | 01-JAN-00:15 | 2339.82 | 30-MAY-18:00 |
EnergyTransfer:Zone:T S1 APARTMENT | 23.81 | 0.00 | 21-MAR-18:45 | 4688.84 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 12.99 | 0.00 | 02-JAN-13:00 | 4688.84 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 10.82 | 0.00 | 01-JAN-00:15 | 3334.72 | 04-SEP-12:30 |
EnergyTransfer:Zone:T S2 APARTMENT | 23.82 | 0.04 | 17-OCT-19:15 | 4689.15 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 12.99 | 0.00 | 02-JAN-13:00 | 4689.15 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 10.83 | 0.00 | 01-JAN-00:15 | 3348.35 | 04-SEP-12:30 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Plant | 1932.09 | 465.63 | 13-AUG-01:15 | 332836.44 | 27-JAN-07:15 |
WaterSystems:EnergyTransfer | 916.94 | 465.63 | 13-AUG-01:15 | 63273.40 | 12-FEB-07:30 |
sub cat:WaterSystems:EnergyTransfer | 916.94 | 465.63 | 13-AUG-01:15 | 63273.40 | 12-FEB-07:30 |
EnergyTransfer:HVAC | 2692.92 | 0.00 | 10-MAR-17:15 | 426084.31 | 27-JAN-01:00 |
CoolingCoils:EnergyTransfer | 1312.49 | 0.00 | 01-JAN-00:15 | 341588.26 | 22-AUG-13:45 |
HeatingCoils:EnergyTransfer | 1380.42 | 0.00 | 10-MAR-15:45 | 426084.31 | 27-JAN-01:00 |
PlantLoopHeatingDemand:HVAC | 1059.39 | 0.00 | 10-MAR-15:45 | 273413.85 | 27-JAN-01:00 |
HeatingCoils:PlantLoopHeatingDemand | 1059.39 | 0.00 | 10-MAR-15:45 | 273413.85 | 27-JAN-01:00 |
Boilers:EnergyTransfer | 1015.15 | 0.00 | 11-FEB-13:15 | 271725.56 | 27-JAN-01:30 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 10.775 | -8.053 | 0.000 | 0.000 | 3.858 | 1.087 | 12.213 | 18.374 | 0.000 | 0.350 | 0.000 | 0.000 | -11.643 | 0.000 | -10.735 | -16.226 |
G NW APARTMENT | 14.351 | -5.945 | 0.000 | 0.000 | 3.878 | 1.087 | 12.213 | 9.809 | 0.000 | 0.347 | 0.000 | 0.000 | -12.235 | 0.000 | -10.472 | -13.032 |
OFFICE | 8.279 | -16.558 | 0.000 | 0.000 | 0.529 | 29.882 | 9.495 | 18.388 | 0.000 | 0.233 | 0.000 | 0.000 | -11.704 | 0.000 | -7.880 | -30.663 |
G NE APARTMENT | 14.140 | -6.002 | 0.000 | 0.000 | 3.885 | 1.087 | 12.213 | 9.841 | 0.000 | 0.347 | 0.000 | 0.000 | -12.009 | 0.000 | -10.488 | -13.013 |
G N1 APARTMENT | 8.330 | -4.664 | 0.000 | 0.000 | 3.888 | 1.087 | 12.213 | 3.802 | 0.000 | 0.255 | 0.000 | 0.000 | -7.694 | 0.000 | -7.247 | -9.971 |
G N2 APARTMENT | 8.327 | -4.663 | 0.000 | 0.000 | 3.889 | 1.087 | 12.213 | 3.800 | 0.000 | 0.255 | 0.000 | 0.000 | -7.692 | 0.000 | -7.249 | -9.967 |
G S1 APARTMENT | 4.950 | -7.223 | 0.000 | 0.000 | 3.859 | 1.087 | 12.213 | 12.448 | 0.000 | 0.257 | 0.000 | 0.000 | -7.090 | 0.000 | -7.549 | -12.950 |
G S2 APARTMENT | 4.750 | -7.454 | 0.000 | 0.000 | 3.854 | 1.087 | 12.213 | 12.431 | 0.000 | 0.258 | 0.000 | 0.000 | -7.106 | 0.000 | -7.593 | -12.439 |
F2 SW APARTMENT | 9.941 | -12.994 | 0.000 | 0.000 | 3.808 | 1.087 | 12.213 | 17.730 | 0.000 | 0.475 | 0.000 | 0.000 | -12.403 | 0.000 | -14.991 | -4.865 |
F2 NW APARTMENT | 14.259 | -9.564 | 0.000 | 0.000 | 3.843 | 1.087 | 12.213 | 9.383 | 0.000 | 0.470 | 0.000 | 0.000 | -12.967 | 0.000 | -14.585 | -4.139 |
F2 SE APARTMENT | 8.999 | -14.319 | 0.000 | 0.000 | 3.799 | 1.087 | 12.213 | 17.778 | 0.000 | 0.475 | 0.000 | 0.000 | -12.339 | 0.000 | -15.137 | -2.557 |
F2 NE APARTMENT | 13.975 | -9.747 | 0.000 | 0.000 | 3.853 | 1.087 | 12.213 | 9.423 | 0.000 | 0.467 | 0.000 | 0.000 | -12.702 | 0.000 | -14.561 | -4.006 |
F2 N1 APARTMENT | 6.671 | -7.633 | 0.000 | 0.000 | 3.851 | 1.087 | 12.213 | 3.572 | 0.000 | 0.336 | 0.000 | 0.000 | -8.200 | 0.000 | -9.980 | -1.916 |
F2 N2 APARTMENT | 6.670 | -7.642 | 0.000 | 0.000 | 3.851 | 1.087 | 12.213 | 3.572 | 0.000 | 0.336 | 0.000 | 0.000 | -8.198 | 0.000 | -9.979 | -1.910 |
F2 S1 APARTMENT | 3.504 | -11.742 | 0.000 | 0.000 | 3.800 | 1.087 | 12.213 | 12.036 | 0.000 | 0.343 | 0.000 | 0.000 | -7.555 | 0.000 | -10.434 | -3.251 |
F2 S2 APARTMENT | 3.463 | -11.854 | 0.000 | 0.000 | 3.798 | 1.087 | 12.213 | 12.030 | 0.000 | 0.343 | 0.000 | 0.000 | -7.562 | 0.000 | -10.452 | -3.065 |
F3 SW APARTMENT | 10.592 | -13.503 | 0.000 | 0.000 | 3.802 | 1.087 | 12.213 | 17.485 | 0.000 | 0.582 | 0.000 | 0.000 | -12.635 | 0.000 | -17.379 | -2.244 |
F3 NW APARTMENT | 15.021 | -10.067 | 0.000 | 0.000 | 3.838 | 1.087 | 12.213 | 9.239 | 0.000 | 0.576 | 0.000 | 0.000 | -13.218 | 0.000 | -16.940 | -1.747 |
F3 SE APARTMENT | 10.283 | -13.853 | 0.000 | 0.000 | 3.805 | 1.087 | 12.213 | 17.592 | 0.000 | 0.582 | 0.000 | 0.000 | -12.474 | 0.000 | -17.416 | -1.819 |
F3 NE APARTMENT | 14.735 | -10.255 | 0.000 | 0.000 | 3.848 | 1.087 | 12.213 | 9.283 | 0.000 | 0.569 | 0.000 | 0.000 | -12.938 | 0.000 | -16.908 | -1.634 |
F3 N1 APARTMENT | 6.763 | -8.250 | 0.000 | 0.000 | 3.842 | 1.087 | 12.213 | 3.504 | 0.000 | 0.416 | 0.329 | 0.000 | -8.371 | 0.000 | -11.532 | -0.000 |
F3 N2 APARTMENT | 6.764 | -8.258 | 0.000 | 0.000 | 3.843 | 1.087 | 12.213 | 3.503 | 0.000 | 0.415 | 0.332 | 0.000 | -8.368 | 0.000 | -11.530 | -0.000 |
F3 S1 APARTMENT | 3.569 | -12.531 | 0.000 | 0.000 | 3.789 | 1.087 | 12.213 | 11.869 | 0.000 | 0.426 | 0.001 | 0.000 | -7.713 | 0.000 | -12.027 | -0.680 |
F3 S2 APARTMENT | 3.561 | -12.567 | 0.000 | 0.000 | 3.788 | 1.087 | 12.213 | 11.866 | 0.000 | 0.426 | 0.001 | 0.000 | -7.714 | 0.000 | -12.034 | -0.626 |
F4 SW APARTMENT | 11.578 | -13.466 | 0.000 | 0.000 | 3.803 | 1.087 | 12.213 | 17.335 | 0.000 | 0.638 | 0.000 | 0.000 | -12.756 | 0.000 | -18.868 | -1.563 |
F4 NW APARTMENT | 16.098 | -10.104 | 0.000 | 0.000 | 3.838 | 1.087 | 12.213 | 9.155 | 0.000 | 0.631 | 0.000 | 0.000 | -13.358 | 0.000 | -18.440 | -1.120 |
F4 SE APARTMENT | 11.376 | -13.667 | 0.000 | 0.000 | 3.807 | 1.087 | 12.213 | 17.456 | 0.000 | 0.637 | 0.001 | 0.000 | -12.572 | 0.000 | -18.885 | -1.453 |
F4 NE APARTMENT | 15.792 | -10.276 | 0.000 | 0.000 | 3.847 | 1.087 | 12.213 | 9.201 | 0.000 | 0.623 | 0.000 | 0.000 | -13.068 | 0.000 | -18.406 | -1.013 |
F4 N1 APARTMENT | 7.245 | -8.347 | 0.000 | 0.000 | 3.839 | 1.087 | 12.213 | 3.467 | 0.000 | 0.453 | 0.935 | 0.000 | -8.466 | 0.000 | -12.425 | -0.000 |
F4 N2 APARTMENT | 7.242 | -8.352 | 0.000 | 0.000 | 3.840 | 1.087 | 12.213 | 3.466 | 0.000 | 0.452 | 0.939 | 0.000 | -8.463 | 0.000 | -12.423 | -0.000 |
F4 S1 APARTMENT | 3.973 | -12.593 | 0.000 | 0.000 | 3.787 | 1.087 | 12.213 | 11.768 | 0.000 | 0.464 | 0.006 | 0.000 | -7.793 | 0.000 | -12.910 | -0.000 |
F4 S2 APARTMENT | 3.974 | -12.608 | 0.000 | 0.000 | 3.787 | 1.087 | 12.213 | 11.766 | 0.000 | 0.464 | 0.023 | 0.000 | -7.792 | 0.000 | -12.914 | -0.000 |
M SW APARTMENT | 12.403 | -13.472 | 0.000 | 0.000 | 3.805 | 1.087 | 12.213 | 17.221 | 0.000 | 0.683 | 0.000 | 0.000 | -12.851 | 0.000 | -20.327 | -0.763 |
M NW APARTMENT | 16.963 | -10.209 | 0.000 | 0.000 | 3.839 | 1.087 | 12.213 | 9.092 | 0.000 | 0.675 | 0.000 | 0.000 | -13.469 | 0.000 | -19.886 | -0.304 |
M SE APARTMENT | 12.209 | -13.641 | 0.000 | 0.000 | 3.810 | 1.087 | 12.213 | 17.347 | 0.000 | 0.682 | 0.000 | 0.000 | -12.657 | 0.000 | -20.340 | -0.708 |
M NE APARTMENT | 16.638 | -10.371 | 0.000 | 0.000 | 3.848 | 1.087 | 12.213 | 9.140 | 0.000 | 0.666 | 0.000 | 0.000 | -13.173 | 0.000 | -19.850 | -0.197 |
M N1 APARTMENT | 7.636 | -8.488 | 0.000 | 0.000 | 3.839 | 1.087 | 12.213 | 3.440 | 0.000 | 0.482 | 1.699 | 0.000 | -8.540 | 0.000 | -13.366 | -0.001 |
M N2 APARTMENT | 7.634 | -8.494 | 0.000 | 0.000 | 3.840 | 1.087 | 12.213 | 3.439 | 0.000 | 0.481 | 1.702 | 0.000 | -8.537 | 0.000 | -13.364 | -0.000 |
M S1 APARTMENT | 4.308 | -12.637 | 0.000 | 0.000 | 3.788 | 1.087 | 12.213 | 11.691 | 0.000 | 0.494 | 0.775 | 0.000 | -7.853 | 0.000 | -13.865 | -0.000 |
M S2 APARTMENT | 4.311 | -12.646 | 0.000 | 0.000 | 3.788 | 1.087 | 12.213 | 11.689 | 0.000 | 0.494 | 0.784 | 0.000 | -7.852 | 0.000 | -13.868 | -0.000 |
F6 SW APARTMENT | 13.689 | -12.813 | 0.000 | 0.000 | 3.813 | 1.087 | 12.213 | 17.162 | 0.000 | 0.720 | 0.000 | 0.000 | -12.870 | 0.000 | -21.516 | -1.485 |
F6 NW APARTMENT | 18.421 | -9.741 | 0.000 | 0.000 | 3.847 | 1.087 | 12.213 | 9.071 | 0.000 | 0.711 | 0.000 | 0.000 | -13.501 | 0.000 | -21.060 | -1.046 |
F6 SE APARTMENT | 13.479 | -12.964 | 0.000 | 0.000 | 3.818 | 1.087 | 12.213 | 17.291 | 0.000 | 0.718 | 0.001 | 0.000 | -12.672 | 0.000 | -21.530 | -1.440 |
F6 NE APARTMENT | 18.076 | -9.883 | 0.000 | 0.000 | 3.856 | 1.087 | 12.213 | 9.120 | 0.000 | 0.701 | 0.000 | 0.000 | -13.201 | 0.000 | -21.023 | -0.944 |
F6 N1 APARTMENT | 8.556 | -8.013 | 0.000 | 0.000 | 3.847 | 1.087 | 12.213 | 3.437 | 0.000 | 0.506 | 1.026 | 0.000 | -8.558 | 0.000 | -14.100 | -0.000 |
F6 N2 APARTMENT | 8.551 | -8.015 | 0.000 | 0.000 | 3.848 | 1.087 | 12.213 | 3.436 | 0.000 | 0.505 | 1.030 | 0.000 | -8.556 | 0.000 | -14.097 | -0.000 |
F6 S1 APARTMENT | 4.994 | -11.898 | 0.000 | 0.000 | 3.797 | 1.087 | 12.213 | 11.651 | 0.000 | 0.519 | 0.121 | 0.000 | -7.862 | 0.000 | -14.621 | -0.000 |
F6 S2 APARTMENT | 4.996 | -11.902 | 0.000 | 0.000 | 3.797 | 1.087 | 12.213 | 11.649 | 0.000 | 0.519 | 0.126 | 0.000 | -7.860 | 0.000 | -14.624 | -0.000 |
F7 SW APARTMENT | 14.744 | -12.427 | 0.000 | 0.000 | 3.820 | 1.087 | 12.213 | 17.105 | 0.000 | 0.751 | 0.000 | 0.000 | -12.897 | 0.000 | -22.566 | -1.829 |
F7 NW APARTMENT | 19.565 | -9.486 | 0.000 | 0.000 | 3.852 | 1.087 | 12.213 | 9.047 | 0.000 | 0.742 | 0.000 | 0.000 | -13.542 | 0.000 | -22.103 | -1.374 |
F7 SE APARTMENT | 14.519 | -12.563 | 0.000 | 0.000 | 3.825 | 1.087 | 12.213 | 17.237 | 0.000 | 0.749 | 0.000 | 0.000 | -12.696 | 0.000 | -22.583 | -1.786 |
F7 NE APARTMENT | 19.206 | -9.616 | 0.000 | 0.000 | 3.861 | 1.087 | 12.213 | 9.097 | 0.000 | 0.731 | 0.000 | 0.000 | -13.238 | 0.000 | -22.066 | -1.274 |
F7 N1 APARTMENT | 9.258 | -7.755 | 0.000 | 0.000 | 3.853 | 1.087 | 12.213 | 3.431 | 0.000 | 0.526 | 0.722 | 0.000 | -8.582 | 0.000 | -14.751 | -0.000 |
F7 N2 APARTMENT | 9.255 | -7.761 | 0.000 | 0.000 | 3.853 | 1.087 | 12.213 | 3.430 | 0.000 | 0.525 | 0.727 | 0.000 | -8.579 | 0.000 | -14.749 | -0.000 |
F7 S1 APARTMENT | 5.559 | -11.447 | 0.000 | 0.000 | 3.803 | 1.087 | 12.213 | 11.613 | 0.000 | 0.540 | 0.000 | 0.000 | -7.876 | 0.000 | -15.287 | -0.205 |
F7 S2 APARTMENT | 5.559 | -11.450 | 0.000 | 0.000 | 3.804 | 1.087 | 12.213 | 11.611 | 0.000 | 0.540 | 0.002 | 0.000 | -7.875 | 0.000 | -15.291 | -0.198 |
F8 SW APARTMENT | 15.771 | -12.170 | 0.000 | 0.000 | 3.825 | 1.087 | 12.213 | 17.055 | 0.000 | 0.785 | 0.000 | 0.000 | -12.923 | 0.000 | -23.538 | -2.104 |
F8 NW APARTMENT | 20.665 | -9.341 | 0.000 | 0.000 | 3.856 | 1.087 | 12.213 | 9.024 | 0.000 | 0.775 | 0.000 | 0.000 | -13.580 | 0.000 | -23.071 | -1.627 |
F8 SE APARTMENT | 15.529 | -12.289 | 0.000 | 0.000 | 3.830 | 1.087 | 12.213 | 17.188 | 0.000 | 0.783 | 0.000 | 0.000 | -12.719 | 0.000 | -23.559 | -2.062 |
F8 NE APARTMENT | 20.308 | -9.460 | 0.000 | 0.000 | 3.864 | 1.087 | 12.213 | 9.075 | 0.000 | 0.766 | 0.000 | 0.000 | -13.275 | 0.000 | -23.042 | -1.536 |
F8 N1 APARTMENT | 9.966 | -7.606 | 0.000 | 0.000 | 3.857 | 1.087 | 12.213 | 3.424 | 0.000 | 0.549 | 0.480 | 0.000 | -8.604 | 0.000 | -15.365 | -0.000 |
F8 N2 APARTMENT | 9.960 | -7.611 | 0.000 | 0.000 | 3.858 | 1.087 | 12.213 | 3.423 | 0.000 | 0.549 | 0.486 | 0.000 | -8.601 | 0.000 | -15.363 | -0.000 |
F8 S1 APARTMENT | 6.144 | -11.127 | 0.000 | 0.000 | 3.809 | 1.087 | 12.213 | 11.580 | 0.000 | 0.565 | 0.000 | 0.000 | -7.888 | 0.000 | -15.910 | -0.471 |
F8 S2 APARTMENT | 6.142 | -11.128 | 0.000 | 0.000 | 3.809 | 1.087 | 12.213 | 11.578 | 0.000 | 0.565 | 0.000 | 0.000 | -7.887 | 0.000 | -15.914 | -0.465 |
F9 SW APARTMENT | 17.540 | -12.123 | 0.000 | 0.000 | 3.830 | 1.087 | 12.213 | 17.022 | 0.000 | 0.819 | 0.000 | 0.000 | -12.920 | 0.000 | -24.421 | -3.047 |
F9 NW APARTMENT | 22.564 | -9.422 | 0.000 | 0.000 | 3.860 | 1.087 | 12.213 | 9.007 | 0.000 | 0.809 | 0.000 | 0.000 | -13.591 | 0.000 | -23.963 | -2.564 |
F9 SE APARTMENT | 17.257 | -12.203 | 0.000 | 0.000 | 3.835 | 1.087 | 12.213 | 17.156 | 0.000 | 0.817 | 0.000 | 0.000 | -12.715 | 0.000 | -24.447 | -2.999 |
F9 NE APARTMENT | 22.193 | -9.509 | 0.000 | 0.000 | 3.867 | 1.087 | 12.213 | 9.059 | 0.000 | 0.803 | 0.000 | 0.000 | -13.285 | 0.000 | -23.946 | -2.483 |
F9 N1 APARTMENT | 11.396 | -7.624 | 0.000 | 0.000 | 3.861 | 1.087 | 12.213 | 3.420 | 0.000 | 0.576 | 0.000 | 0.000 | -8.606 | 0.000 | -15.933 | -0.389 |
F9 N2 APARTMENT | 11.389 | -7.627 | 0.000 | 0.000 | 3.861 | 1.087 | 12.213 | 3.419 | 0.000 | 0.576 | 0.000 | 0.000 | -8.604 | 0.000 | -15.932 | -0.382 |
F9 S1 APARTMENT | 7.301 | -10.912 | 0.000 | 0.000 | 3.816 | 1.087 | 12.213 | 11.560 | 0.000 | 0.591 | 0.000 | 0.000 | -7.881 | 0.000 | -16.471 | -1.304 |
F9 S2 APARTMENT | 7.300 | -10.915 | 0.000 | 0.000 | 3.816 | 1.087 | 12.213 | 11.558 | 0.000 | 0.591 | 0.000 | 0.000 | -7.879 | 0.000 | -16.475 | -1.296 |
T SW APARTMENT | 24.480 | -12.710 | 0.000 | 0.000 | 3.854 | 1.087 | 12.213 | 16.793 | 0.000 | 0.841 | 0.000 | 0.000 | -12.461 | 0.000 | -25.156 | -8.940 |
T NW APARTMENT | 28.779 | -10.081 | 0.000 | 0.000 | 3.876 | 1.087 | 12.213 | 8.832 | 0.000 | 0.830 | 0.000 | 0.000 | -13.180 | 0.000 | -24.737 | -7.616 |
T SE APARTMENT | 24.068 | -12.584 | 0.000 | 0.000 | 3.859 | 1.087 | 12.213 | 16.948 | 0.000 | 0.840 | 0.000 | 0.000 | -12.275 | 0.000 | -25.192 | -8.964 |
T NE APARTMENT | 28.219 | -9.955 | 0.000 | 0.000 | 3.885 | 1.087 | 12.213 | 8.907 | 0.000 | 0.825 | 0.000 | 0.000 | -12.893 | 0.000 | -24.719 | -7.568 |
T N1 APARTMENT | 16.852 | -7.967 | 0.000 | 0.000 | 3.877 | 1.087 | 12.213 | 3.360 | 0.000 | 0.594 | 0.000 | 0.000 | -8.330 | 0.000 | -16.408 | -5.277 |
T N2 APARTMENT | 16.850 | -7.967 | 0.000 | 0.000 | 3.878 | 1.087 | 12.213 | 3.358 | 0.000 | 0.594 | 0.000 | 0.000 | -8.327 | 0.000 | -16.411 | -5.273 |
T S1 APARTMENT | 12.990 | -10.820 | 0.000 | 0.000 | 3.841 | 1.087 | 12.213 | 11.437 | 0.000 | 0.608 | 0.000 | 0.000 | -7.631 | 0.000 | -16.916 | -6.808 |
T S2 APARTMENT | 12.994 | -10.828 | 0.000 | 0.000 | 3.841 | 1.087 | 12.213 | 11.434 | 0.000 | 0.608 | 0.000 | 0.000 | -7.628 | 0.000 | -16.923 | -6.798 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 4.156 | 0.000 | 1.273 | 44.186 | 0.000 | -2.570 | 0.000 | -63.484 | -0.002 |
F2 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 1.856 | 0.000 | 0.026 | 0.000 | 0.000 | -1.590 | 0.000 | -1.996 | -14.735 |
F3 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 1.815 | 0.000 | 0.029 | 0.000 | 0.000 | -1.658 | 0.000 | -2.426 | -14.200 |
F4 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 1.793 | 0.000 | 0.031 | 0.000 | 0.000 | -1.688 | 0.000 | -2.733 | -13.842 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32.880 | 0.000 | 1.767 | 0.000 | 0.026 | 0.000 | 0.000 | -1.729 | 0.000 | -3.076 | -29.867 |
F6 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 1.776 | 0.000 | 0.035 | 0.000 | 0.000 | -1.703 | 0.000 | -3.163 | -13.386 |
F7 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 1.776 | 0.000 | 0.038 | 0.000 | 0.000 | -1.696 | 0.000 | -3.315 | -13.243 |
F8 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 1.772 | 0.000 | 0.040 | 0.000 | 0.000 | -1.696 | 0.000 | -3.461 | -13.094 |
F9 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 1.770 | 0.000 | 0.039 | 0.000 | 0.000 | -1.692 | 0.000 | -3.586 | -12.971 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 8.151 | 1.722 | 0.000 | 0.016 | 0.000 | 0.000 | -1.647 | 0.000 | -3.785 | -20.899 |
Total Facility | 947.137 | -826.425 | 0.000 | 0.000 | 303.563 | 296.560 | 982.450 | 856.641 | 0.000 | 46.771 | 56.437 | 0.000 | -853.447 | 0.000 | -1412.042 | -397.639 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 05-SEP-15:15 | 0.00 | -2600.78 | 0.00 | 0.00 | 48.90 | 45.40 | 470.89 | 3527.40 | 0.00 | 71.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1563.75 |
G NW APARTMENT | 25-JUL-17:08 | 0.00 | -2291.63 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 2361.19 | 0.00 | 353.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1240.81 |
OFFICE | 05-SEP-13:30 | 0.00 | -3728.98 | 0.00 | 0.00 | 65.20 | 2345.88 | 588.62 | 2997.17 | 0.00 | 80.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2348.11 |
G NE APARTMENT | 15-JUN-08:45 | 0.00 | -1779.04 | 0.00 | 0.00 | 40.76 | 12.97 | 394.37 | 2543.29 | 0.00 | 358.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1570.64 |
G N1 APARTMENT | 25-JUL-17:08 | 0.00 | -1244.52 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 475.16 | 0.00 | 327.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -376.39 |
G N2 APARTMENT | 25-JUL-17:08 | 0.00 | -1245.26 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 475.70 | 0.00 | 329.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -377.82 |
G S1 APARTMENT | 30-AUG-13:15 | 0.00 | -1869.73 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 2695.09 | 0.00 | 207.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1468.85 |
G S2 APARTMENT | 30-AUG-13:15 | 0.00 | -1922.48 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 2694.02 | 0.00 | 207.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1415.02 |
F2 SW APARTMENT | 05-SEP-15:15 | 0.00 | -3304.24 | 0.00 | 0.00 | 48.90 | 45.40 | 470.89 | 3489.61 | 0.00 | 103.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -853.59 |
F2 NW APARTMENT | 25-JUL-17:08 | 0.00 | -2973.57 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 2325.76 | 0.00 | 456.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -626.48 |
F2 SE APARTMENT | 28-SEP-12:30 | 0.00 | -3177.17 | 0.00 | 0.00 | 40.76 | 12.97 | 388.49 | 3827.77 | 0.00 | 184.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1277.28 |
F2 NE APARTMENT | 16-JUN-08:45 | 0.00 | -2293.48 | 0.00 | 0.00 | 40.76 | 12.97 | 394.37 | 2373.00 | 0.00 | 361.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -888.80 |
F2 N1 APARTMENT | 28-JUN-18:15 | 0.00 | -1690.36 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 457.00 | 0.00 | 296.61 | 143.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 N2 APARTMENT | 28-JUN-18:15 | 0.00 | -1682.27 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 457.16 | 0.00 | 296.62 | 135.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 S1 APARTMENT | 30-AUG-13:15 | 0.00 | -2392.12 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 2672.76 | 0.00 | 228.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -945.82 |
F2 S2 APARTMENT | 30-AUG-13:15 | 0.00 | -2409.10 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 2672.47 | 0.00 | 228.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -928.55 |
F3 SW APARTMENT | 16-APR-14:30 | 0.00 | -3368.38 | 0.00 | 0.00 | 40.76 | 22.70 | 400.26 | 3538.20 | 0.00 | 417.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1051.41 |
F3 NW APARTMENT | 25-JUL-17:08 | 0.00 | -3047.03 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 2311.26 | 0.00 | 518.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -600.86 |
F3 SE APARTMENT | 16-APR-13:15 | 0.00 | -3148.75 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 2906.86 | 0.00 | 388.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -582.79 |
F3 NE APARTMENT | 16-JUN-09:00 | 0.00 | -2411.87 | 0.00 | 0.00 | 40.76 | 12.97 | 394.37 | 2346.70 | 0.00 | 500.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -883.51 |
F3 N1 APARTMENT | 20-JUL-18:00 | 0.00 | -1852.80 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 358.00 | 0.00 | 394.32 | 282.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 N2 APARTMENT | 20-JUL-18:00 | 0.00 | -1847.87 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 358.09 | 0.00 | 394.33 | 277.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 S1 APARTMENT | 26-SEP-13:00 | 0.00 | -2551.65 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2692.87 | 0.00 | 492.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1075.70 |
F3 S2 APARTMENT | 26-SEP-13:00 | 0.00 | -2562.13 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2692.67 | 0.00 | 492.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1065.02 |
F4 SW APARTMENT | 16-APR-14:30 | 0.00 | -3415.37 | 0.00 | 0.00 | 40.76 | 22.70 | 400.26 | 3514.92 | 0.00 | 465.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1028.74 |
F4 NW APARTMENT | 25-JUL-17:08 | 0.00 | -3077.69 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 2301.39 | 0.00 | 563.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -605.05 |
F4 SE APARTMENT | 16-APR-13:15 | 0.00 | -3192.08 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 2888.86 | 0.00 | 432.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -565.61 |
F4 NE APARTMENT | 16-JUN-09:00 | 0.00 | -2442.54 | 0.00 | 0.00 | 40.76 | 12.97 | 394.37 | 2333.65 | 0.00 | 542.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -881.39 |
F4 N1 APARTMENT | 20-JUL-18:00 | 0.00 | -1893.99 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 356.38 | 0.00 | 424.73 | 294.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 N2 APARTMENT | 20-JUL-18:00 | 0.00 | -1889.42 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 356.47 | 0.00 | 424.73 | 290.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 S1 APARTMENT | 26-SEP-13:00 | 0.00 | -2610.76 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2676.20 | 0.00 | 535.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1043.35 |
F4 S2 APARTMENT | 26-SEP-13:00 | 0.00 | -2619.29 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2676.04 | 0.00 | 535.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1034.66 |
M SW APARTMENT | 16-APR-14:30 | 0.00 | -3463.58 | 0.00 | 0.00 | 40.76 | 22.70 | 400.26 | 3497.08 | 0.00 | 504.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1001.36 |
M NW APARTMENT | 25-JUL-17:08 | 0.00 | -3125.33 | 0.00 | 0.00 | 141.83 | 87.56 | 588.62 | 2293.06 | 0.00 | 599.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -584.88 |
M SE APARTMENT | 16-APR-13:15 | 0.00 | -3238.69 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 2874.88 | 0.00 | 468.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -540.83 |
M NE APARTMENT | 16-JUN-09:00 | 0.00 | -2488.15 | 0.00 | 0.00 | 40.76 | 12.97 | 394.37 | 2322.88 | 0.00 | 575.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -858.28 |
M N1 APARTMENT | 20-JUL-18:00 | 0.00 | -1946.07 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 354.65 | 0.00 | 449.17 | 324.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 20-JUL-18:00 | 0.00 | -1941.64 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 354.73 | 0.00 | 449.18 | 319.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | 26-SEP-13:00 | 0.00 | -2660.04 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2663.17 | 0.00 | 570.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1015.77 |
M S2 APARTMENT | 26-SEP-13:00 | 0.00 | -2668.17 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2663.02 | 0.00 | 570.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1007.48 |
F6 SW APARTMENT | 16-APR-14:30 | 0.00 | -3445.86 | 0.00 | 0.00 | 40.76 | 22.70 | 400.26 | 3484.52 | 0.00 | 536.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1039.34 |
F6 NW APARTMENT | 25-JUL-17:08 | 0.00 | -3104.65 | 0.00 | 0.00 | 141.83 | 87.56 | 588.62 | 2287.74 | 0.00 | 628.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -629.20 |
F6 SE APARTMENT | 16-APR-13:15 | 0.00 | -3220.40 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 2865.35 | 0.00 | 498.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -579.94 |
F6 NE APARTMENT | 16-JUN-09:00 | 0.00 | -2470.84 | 0.00 | 0.00 | 40.75 | 12.97 | 394.37 | 2315.57 | 0.00 | 602.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -895.14 |
F6 N1 APARTMENT | 20-JUL-18:00 | 0.00 | -1937.05 | 0.00 | 0.00 | 141.83 | 87.56 | 588.62 | 354.22 | 0.00 | 469.56 | 295.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 N2 APARTMENT | 20-JUL-18:00 | 0.00 | -1929.30 | 0.00 | 0.00 | 141.83 | 87.56 | 588.62 | 354.30 | 0.00 | 469.09 | 287.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 S1 APARTMENT | 26-SEP-13:00 | 0.00 | -2632.46 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2653.77 | 0.00 | 599.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1062.82 |
F6 S2 APARTMENT | 26-SEP-13:00 | 0.00 | -2640.47 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2653.62 | 0.00 | 599.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1054.65 |
F7 SW APARTMENT | 16-APR-14:30 | 0.00 | -3446.89 | 0.00 | 0.00 | 40.76 | 22.70 | 400.26 | 3473.54 | 0.00 | 565.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1055.97 |
F7 NW APARTMENT | 25-JUL-17:08 | 0.00 | -3106.44 | 0.00 | 0.00 | 141.83 | 87.56 | 588.62 | 2282.49 | 0.00 | 652.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -646.93 |
F7 SE APARTMENT | 16-APR-13:15 | 0.00 | -3221.48 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 2856.84 | 0.00 | 525.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -596.82 |
F7 NE APARTMENT | 16-JUN-09:00 | 0.00 | -2473.91 | 0.00 | 0.00 | 40.75 | 12.97 | 394.37 | 2308.60 | 0.00 | 625.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -907.95 |
F7 N1 APARTMENT | 20-JUL-18:00 | 0.00 | -1945.69 | 0.00 | 0.00 | 141.83 | 87.56 | 588.62 | 353.45 | 0.00 | 486.94 | 287.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 N2 APARTMENT | 20-JUL-18:00 | 0.00 | -1933.36 | 0.00 | 0.00 | 141.83 | 87.56 | 588.62 | 353.53 | 0.00 | 485.79 | 276.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 S1 APARTMENT | 26-SEP-13:00 | 0.00 | -2618.36 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2645.57 | 0.00 | 623.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1093.28 |
F7 S2 APARTMENT | 26-SEP-13:00 | 0.00 | -2626.43 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2645.41 | 0.00 | 623.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1085.05 |
F8 SW APARTMENT | 16-APR-14:30 | 0.00 | -3458.44 | 0.00 | 0.00 | 40.76 | 22.70 | 400.26 | 3463.78 | 0.00 | 591.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1060.12 |
F8 NW APARTMENT | 25-JUL-17:08 | 0.00 | -3121.10 | 0.00 | 0.00 | 141.83 | 87.56 | 588.62 | 2277.59 | 0.00 | 674.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -649.01 |
F8 SE APARTMENT | 16-APR-13:15 | 0.00 | -3236.47 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 2849.05 | 0.00 | 548.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -597.54 |
F8 NE APARTMENT | 16-JUN-09:00 | 0.00 | -2545.45 | 0.00 | 0.00 | 40.76 | 12.97 | 394.37 | 2302.37 | 0.00 | 656.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -861.96 |
F8 N1 APARTMENT | 20-JUL-18:00 | 0.00 | -1963.35 | 0.00 | 0.00 | 141.83 | 87.56 | 588.62 | 352.47 | 0.00 | 501.96 | 290.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 N2 APARTMENT | 20-JUL-18:00 | 0.00 | -1950.21 | 0.00 | 0.00 | 141.83 | 87.56 | 588.62 | 352.57 | 0.00 | 500.74 | 278.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 S1 APARTMENT | 26-SEP-13:00 | 0.00 | -2597.79 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2638.60 | 0.00 | 645.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1128.10 |
F8 S2 APARTMENT | 26-SEP-13:00 | 0.00 | -2605.99 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2638.44 | 0.00 | 645.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1119.74 |
F9 SW APARTMENT | 16-APR-14:30 | 0.00 | -3527.30 | 0.00 | 0.00 | 40.76 | 22.70 | 400.26 | 3453.29 | 0.00 | 614.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1003.73 |
F9 NW APARTMENT | 25-JUL-17:08 | 0.00 | -3228.32 | 0.00 | 0.00 | 141.83 | 87.56 | 588.62 | 2270.63 | 0.00 | 696.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -557.01 |
F9 SE APARTMENT | 16-APR-13:15 | 0.00 | -3300.30 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 2840.53 | 0.00 | 569.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -546.36 |
F9 NE APARTMENT | 16-JUN-09:00 | 0.00 | -2692.99 | 0.00 | 0.00 | 40.76 | 12.97 | 394.37 | 2295.87 | 0.00 | 695.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -746.95 |
F9 N1 APARTMENT | 20-JUL-17:45 | 0.00 | -2073.27 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 411.53 | 0.00 | 599.64 | 244.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 N2 APARTMENT | 20-JUL-17:45 | 0.00 | -2059.54 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 411.65 | 0.00 | 598.35 | 231.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 S1 APARTMENT | 26-SEP-13:00 | 0.00 | -2522.36 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2633.70 | 0.00 | 663.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1217.14 |
F9 S2 APARTMENT | 26-SEP-13:00 | 0.00 | -2532.41 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2633.50 | 0.00 | 663.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1206.88 |
T SW APARTMENT | 16-APR-14:15 | 0.00 | -4116.41 | 0.00 | 0.00 | 40.76 | 22.70 | 400.26 | 3504.95 | 0.00 | 634.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -487.21 |
T NW APARTMENT | 19-JUL-14:45 | 0.00 | -3714.81 | 0.00 | 0.00 | 40.55 | 22.70 | 400.26 | 2434.59 | 0.00 | 911.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -95.27 |
T SE APARTMENT | 05-SEP-12:00 | 0.00 | -3821.92 | 0.00 | 0.00 | 40.76 | 12.97 | 406.15 | 3254.57 | 0.00 | 147.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -40.19 |
T NE APARTMENT | 16-JUN-09:00 | 0.00 | -3113.35 | 0.00 | 0.00 | 40.76 | 12.97 | 394.37 | 2261.72 | 0.00 | 714.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -311.06 |
T N1 APARTMENT | 20-JUL-17:45 | 0.00 | -2356.15 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 403.01 | 0.00 | 628.75 | 506.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 30-MAY-18:00 | 0.00 | -2340.08 | 0.00 | 0.00 | 141.83 | 87.56 | 588.62 | 464.45 | 0.00 | 872.43 | 185.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 04-SEP-12:30 | 0.00 | -3334.62 | 0.00 | 0.00 | 40.76 | 12.97 | 388.49 | 2923.13 | 0.00 | 340.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -371.18 |
T S2 APARTMENT | 04-SEP-12:30 | 0.00 | -3348.26 | 0.00 | 0.00 | 40.76 | 12.97 | 388.49 | 2922.85 | 0.00 | 340.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -357.27 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 19-JUL-14:45 | 0.00 | -187257.54 | 0.00 | 0.00 | 3240.32 | 9873.49 | 32370.09 | 127933.18 | 0.00 | 47043.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -33202.98 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 27-JAN-01:00 | 3473.28 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1652.28 | 0.00 | -1878.84 | -403.19 |
G NW APARTMENT | 27-JAN-08:10 | 3679.03 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1461.07 | 0.00 | -1642.19 | -1057.69 |
OFFICE | 26-JAN-23:00 | 3352.47 | 0.00 | 0.00 | 0.00 | 0.00 | 469.18 | 194.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1632.37 | 0.00 | -1944.22 | -439.30 |
G NE APARTMENT | 27-JAN-01:00 | 3528.93 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1653.39 | 0.00 | -1878.86 | -457.71 |
G N1 APARTMENT | 27-JAN-08:10 | 2374.27 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -891.76 | 0.00 | -990.53 | -973.89 |
G N2 APARTMENT | 27-JAN-08:10 | 2369.19 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -891.84 | 0.00 | -990.53 | -968.73 |
G S1 APARTMENT | 27-JAN-01:00 | 2081.52 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1002.30 | 0.00 | -1133.27 | -406.98 |
G S2 APARTMENT | 27-JAN-01:00 | 2066.08 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1002.65 | 0.00 | -1133.27 | -391.19 |
F2 SW APARTMENT | 27-JAN-01:00 | 4175.52 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1711.20 | 0.00 | -2701.37 | -224.00 |
F2 NW APARTMENT | 27-JAN-01:00 | 4278.56 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1732.75 | 0.00 | -2701.37 | -305.48 |
F2 SE APARTMENT | 27-JAN-01:00 | 4100.19 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1695.93 | 0.00 | -2701.37 | -163.92 |
F2 NE APARTMENT | 27-JAN-01:00 | 4290.11 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1714.54 | 0.00 | -2701.38 | -335.22 |
F2 N1 APARTMENT | 27-JAN-01:00 | 2485.58 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1058.27 | 0.00 | -1629.40 | -258.94 |
F2 N2 APARTMENT | 27-JAN-01:00 | 2486.89 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1058.24 | 0.00 | -1629.40 | -260.28 |
F2 S1 APARTMENT | 27-JAN-01:00 | 2375.13 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1033.54 | 0.00 | -1629.40 | -173.23 |
F2 S2 APARTMENT | 27-JAN-01:00 | 2369.87 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1033.66 | 0.00 | -1629.40 | -167.86 |
F3 SW APARTMENT | 27-JAN-01:00 | 4576.84 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1735.93 | 0.00 | -3199.18 | -102.77 |
F3 NW APARTMENT | 27-JAN-01:00 | 4687.96 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1761.70 | 0.00 | -3199.18 | -188.10 |
F3 SE APARTMENT | 27-JAN-01:00 | 4573.60 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1715.06 | 0.00 | -3199.18 | -120.38 |
F3 NE APARTMENT | 27-JAN-01:00 | 4696.80 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1740.71 | 0.00 | -3199.19 | -217.93 |
F3 N1 APARTMENT | 27-JAN-01:00 | 2690.81 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1076.45 | 0.00 | -1929.67 | -145.73 |
F3 N2 APARTMENT | 27-JAN-01:00 | 2692.09 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1076.42 | 0.00 | -1929.67 | -147.03 |
F3 S1 APARTMENT | 27-JAN-01:00 | 2567.70 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1047.06 | 0.00 | -1929.66 | -52.01 |
F3 S2 APARTMENT | 27-JAN-01:00 | 2567.81 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1047.06 | 0.00 | -1929.66 | -52.12 |
F4 SW APARTMENT | 27-JAN-01:00 | 4946.75 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1750.48 | 0.00 | -3576.87 | -80.43 |
F4 NW APARTMENT | 27-JAN-01:00 | 5061.80 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1778.86 | 0.00 | -3576.88 | -167.10 |
F4 SE APARTMENT | 27-JAN-01:00 | 4952.32 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1727.44 | 0.00 | -3576.88 | -109.04 |
F4 NE APARTMENT | 27-JAN-01:00 | 5068.63 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1755.90 | 0.00 | -3576.89 | -196.87 |
F4 N1 APARTMENT | 27-JAN-01:00 | 2907.26 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1087.15 | 0.00 | -2157.49 | -123.65 |
F4 N2 APARTMENT | 27-JAN-01:00 | 2908.49 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1087.12 | 0.00 | -2157.49 | -124.91 |
F4 S1 APARTMENT | 27-JAN-01:00 | 2778.43 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1055.08 | 0.00 | -2157.48 | -26.91 |
F4 S2 APARTMENT | 27-JAN-01:00 | 2779.61 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1055.05 | 0.00 | -2157.48 | -28.11 |
M SW APARTMENT | 27-JAN-01:00 | 5244.54 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1761.77 | 0.00 | -3888.35 | -55.46 |
M NW APARTMENT | 27-JAN-01:00 | 5360.26 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1791.97 | 0.00 | -3888.35 | -140.97 |
M SE APARTMENT | 27-JAN-01:00 | 5249.98 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1737.42 | 0.00 | -3888.35 | -85.23 |
M NE APARTMENT | 27-JAN-01:00 | 5365.64 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1767.77 | 0.00 | -3888.36 | -170.54 |
M N1 APARTMENT | 27-JAN-01:00 | 3078.02 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1095.33 | 0.00 | -2345.36 | -98.36 |
M N2 APARTMENT | 27-JAN-01:00 | 3079.21 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1095.30 | 0.00 | -2345.36 | -99.58 |
M S1 APARTMENT | 27-JAN-01:00 | 2948.21 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1061.34 | 0.00 | -2345.35 | -2.56 |
M S2 APARTMENT | 27-JAN-01:00 | 2949.55 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1061.30 | 0.00 | -2345.35 | -3.93 |
F6 SW APARTMENT | 27-JAN-01:00 | 5555.56 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1768.99 | 0.00 | -4156.89 | -90.72 |
F6 NW APARTMENT | 27-JAN-01:00 | 5672.35 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1800.63 | 0.00 | -4156.89 | -175.87 |
F6 SE APARTMENT | 27-JAN-01:00 | 5559.86 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1743.74 | 0.00 | -4156.89 | -120.26 |
F6 NE APARTMENT | 27-JAN-01:00 | 5676.55 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1775.54 | 0.00 | -4156.90 | -205.15 |
F6 N1 APARTMENT | 27-JAN-01:00 | 3278.33 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1100.61 | 0.00 | -2507.34 | -131.41 |
F6 N2 APARTMENT | 27-JAN-01:00 | 3279.48 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1100.58 | 0.00 | -2507.34 | -132.59 |
F6 S1 APARTMENT | 27-JAN-01:00 | 3147.69 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1065.13 | 0.00 | -2507.33 | -36.26 |
F6 S2 APARTMENT | 27-JAN-01:00 | 3149.01 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1065.10 | 0.00 | -2507.33 | -37.62 |
F7 SW APARTMENT | 27-JAN-01:00 | 5817.15 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1775.48 | 0.00 | -4394.93 | -107.78 |
F7 NW APARTMENT | 27-JAN-01:00 | 5933.35 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1808.27 | 0.00 | -4394.94 | -191.18 |
F7 SE APARTMENT | 27-JAN-01:00 | 5820.34 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1749.52 | 0.00 | -4394.94 | -136.91 |
F7 NE APARTMENT | 27-JAN-01:00 | 5936.54 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1782.46 | 0.00 | -4394.95 | -220.16 |
F7 N1 APARTMENT | 27-JAN-01:00 | 3441.85 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1105.28 | 0.00 | -2650.92 | -146.68 |
F7 N2 APARTMENT | 27-JAN-01:00 | 3442.95 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1105.25 | 0.00 | -2650.93 | -147.81 |
F7 S1 APARTMENT | 27-JAN-01:00 | 3312.96 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1068.91 | 0.00 | -2650.91 | -54.16 |
F7 S2 APARTMENT | 27-JAN-01:00 | 3314.22 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1068.88 | 0.00 | -2650.91 | -55.46 |
F8 SW APARTMENT | 27-JAN-01:00 | 6061.34 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1780.84 | 0.00 | -4610.03 | -131.51 |
F8 NW APARTMENT | 27-JAN-01:00 | 6176.11 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1814.58 | 0.00 | -4610.03 | -212.53 |
F8 SE APARTMENT | 27-JAN-01:00 | 6063.52 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1754.32 | 0.00 | -4610.03 | -160.21 |
F8 NE APARTMENT | 27-JAN-01:00 | 6178.40 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1788.21 | 0.00 | -4610.04 | -241.18 |
F8 N1 APARTMENT | 27-JAN-01:00 | 3596.92 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1109.10 | 0.00 | -2780.66 | -168.19 |
F8 N2 APARTMENT | 27-JAN-01:00 | 3597.97 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1109.07 | 0.00 | -2780.67 | -169.27 |
F8 S1 APARTMENT | 27-JAN-01:00 | 3471.09 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1071.73 | 0.00 | -2780.65 | -79.75 |
F8 S2 APARTMENT | 27-JAN-01:00 | 3472.28 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1071.70 | 0.00 | -2780.65 | -80.96 |
F9 SW APARTMENT | 27-JAN-01:00 | 6407.71 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1781.84 | 0.00 | -4807.11 | -279.78 |
F9 NW APARTMENT | 27-JAN-01:00 | 6517.41 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1816.31 | 0.00 | -4807.12 | -355.01 |
F9 SE APARTMENT | 27-JAN-01:00 | 6408.59 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1754.95 | 0.00 | -4807.12 | -307.56 |
F9 NE APARTMENT | 27-JAN-01:00 | 6518.55 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1789.56 | 0.00 | -4807.13 | -382.89 |
F9 N1 APARTMENT | 27-JAN-01:00 | 3847.43 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1109.97 | 0.00 | -2899.54 | -298.95 |
F9 N2 APARTMENT | 27-JAN-01:00 | 3848.42 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1109.94 | 0.00 | -2899.54 | -299.97 |
F9 S1 APARTMENT | 27-JAN-01:00 | 3728.61 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1071.83 | 0.00 | -2899.53 | -218.28 |
F9 S2 APARTMENT | 27-JAN-01:00 | 3729.70 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1071.81 | 0.00 | -2899.53 | -219.40 |
T SW APARTMENT | 27-JAN-01:00 | 7428.38 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1746.49 | 0.00 | -4989.23 | -1153.69 |
T NW APARTMENT | 27-JAN-01:00 | 7502.32 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1780.39 | 0.00 | -4989.24 | -1193.72 |
T SE APARTMENT | 27-JAN-01:00 | 7416.54 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1720.32 | 0.00 | -4989.24 | -1168.02 |
T NE APARTMENT | 27-JAN-01:00 | 7490.57 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1754.32 | 0.00 | -4989.25 | -1208.04 |
T N1 APARTMENT | 27-JAN-01:00 | 4769.94 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1086.52 | 0.00 | -3009.50 | -1134.95 |
T N2 APARTMENT | 27-JAN-01:00 | 4770.22 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1086.51 | 0.00 | -3009.50 | -1135.23 |
T S1 APARTMENT | 27-JAN-01:00 | 4688.15 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1051.81 | 0.00 | -3009.49 | -1087.89 |
T S2 APARTMENT | 27-JAN-01:00 | 4688.47 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1051.80 | 0.00 | -3009.49 | -1088.21 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 27-JAN-01:00 | 343265.15 | 0.00 | 0.00 | 0.00 | 14983.89 | 6715.87 | 21178.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -115069.74 | 0.00 | -251202.54 | -19871.29 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Sec1.1A-General InformationData | |
Weather File | Chicago Ohare Intl Ap IL USA TMY3 WMO#=725300 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 7836.48 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.50 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F2 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F3 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F4 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F6 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F7 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F8 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F9 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 7836.48 | 7059.89 | 776.58 |
Data | |
Number of hours heating loads not met | 95.50 |
Number of hours cooling loads not met | 99.50 |
Number of hours not met | 195.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 296.56 | 9277.71 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 162.68 | 10364.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 361.26 | 143682.79 | 1355.40 | 359120.69 | 0.00 | 0.00 |
Space Cooling | 382.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 74.60 | 2423.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 17.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 652.60 | 20693.73 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 0.00 | 0.00 | 1177.88 | 83123.27 | 0.00 | 0.00 |
Receptacle Equipment | 1137.32 | 37445.77 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 3121.23 | 2533.28 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 1137.32 | 3121.23 |
Natural Gas | 0.00 | 2533.28 |
Additional | 0.00 | 0.00 |
Total | 1137.32 | 5654.51 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 37.84 |
Space Heating | 46.10 |
Space Cooling | 48.77 |
Fans-Interior | 83.28 |
Service Water Heating | 0.00 |
Receptacle Equipment | 145.13 |
Miscellaneous | 37.17 |
Subtotal | 398.29 |
Natural Gas [MJ/m2] | |
Space Heating | 172.96 |
Service Water Heating | 150.31 |
Miscellaneous | -0.00 |
Subtotal | 323.27 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 5.24 |
Space Heating | 30.36 |
Space Cooling | 6.76 |
Fans-Interior | 11.54 |
Service Water Heating | 20.83 |
Receptacle Equipment | 20.11 |
Miscellaneous | 5.15 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.224065 |
G NW APARTMENT DIRECT AIR | 0.209462 |
OFFICE DIRECT AIR | 0.337282 |
G NE APARTMENT DIRECT AIR | 0.171367 |
G N1 APARTMENT DIRECT AIR | 0.115062 |
G N2 APARTMENT DIRECT AIR | 0.115063 |
G S1 APARTMENT DIRECT AIR | 0.137534 |
G S2 APARTMENT DIRECT AIR | 0.143810 |
F2 SW APARTMENT DIRECT AIR | 0.292244 |
F2 NW APARTMENT DIRECT AIR | 0.271851 |
F2 SE APARTMENT DIRECT AIR | 0.281875 |
F2 NE APARTMENT DIRECT AIR | 0.209124 |
F2 N1 APARTMENT DIRECT AIR | 0.145222 |
F2 N2 APARTMENT DIRECT AIR | 0.143819 |
F2 S1 APARTMENT DIRECT AIR | 0.183767 |
F2 S2 APARTMENT DIRECT AIR | 0.186076 |
F3 SW APARTMENT DIRECT AIR | 0.295372 |
F3 NW APARTMENT DIRECT AIR | 0.275740 |
F3 SE APARTMENT DIRECT AIR | 0.265208 |
F3 NE APARTMENT DIRECT AIR | 0.213529 |
F3 N1 APARTMENT DIRECT AIR | 0.149692 |
F3 N2 APARTMENT DIRECT AIR | 0.148330 |
F3 S1 APARTMENT DIRECT AIR | 0.188100 |
F3 S2 APARTMENT DIRECT AIR | 0.189171 |
F4 SW APARTMENT DIRECT AIR | 0.297736 |
F4 NW APARTMENT DIRECT AIR | 0.278198 |
F4 SE APARTMENT DIRECT AIR | 0.265909 |
F4 NE APARTMENT DIRECT AIR | 0.215501 |
F4 N1 APARTMENT DIRECT AIR | 0.151944 |
F4 N2 APARTMENT DIRECT AIR | 0.150588 |
F4 S1 APARTMENT DIRECT AIR | 0.190123 |
F4 S2 APARTMENT DIRECT AIR | 0.191017 |
M SW APARTMENT DIRECT AIR | 0.301696 |
M NW APARTMENT DIRECT AIR | 0.282260 |
M SE APARTMENT DIRECT AIR | 0.269900 |
M NE APARTMENT DIRECT AIR | 0.219101 |
M N1 APARTMENT DIRECT AIR | 0.155657 |
M N2 APARTMENT DIRECT AIR | 0.154307 |
M S1 APARTMENT DIRECT AIR | 0.193669 |
M S2 APARTMENT DIRECT AIR | 0.194538 |
F6 SW APARTMENT DIRECT AIR | 0.299796 |
F6 NW APARTMENT DIRECT AIR | 0.280302 |
F6 SE APARTMENT DIRECT AIR | 0.268252 |
F6 NE APARTMENT DIRECT AIR | 0.216848 |
F6 N1 APARTMENT DIRECT AIR | 0.153666 |
F6 N2 APARTMENT DIRECT AIR | 0.152327 |
F6 S1 APARTMENT DIRECT AIR | 0.191516 |
F6 S2 APARTMENT DIRECT AIR | 0.192381 |
F7 SW APARTMENT DIRECT AIR | 0.299851 |
F7 NW APARTMENT DIRECT AIR | 0.280381 |
F7 SE APARTMENT DIRECT AIR | 0.268539 |
F7 NE APARTMENT DIRECT AIR | 0.216620 |
F7 N1 APARTMENT DIRECT AIR | 0.153614 |
F7 N2 APARTMENT DIRECT AIR | 0.152283 |
F7 S1 APARTMENT DIRECT AIR | 0.191305 |
F7 S2 APARTMENT DIRECT AIR | 0.192169 |
F8 SW APARTMENT DIRECT AIR | 0.301106 |
F8 NW APARTMENT DIRECT AIR | 0.281671 |
F8 SE APARTMENT DIRECT AIR | 0.269961 |
F8 NE APARTMENT DIRECT AIR | 0.223141 |
F8 N1 APARTMENT DIRECT AIR | 0.154777 |
F8 N2 APARTMENT DIRECT AIR | 0.153456 |
F8 S1 APARTMENT DIRECT AIR | 0.192267 |
F8 S2 APARTMENT DIRECT AIR | 0.193132 |
F9 SW APARTMENT DIRECT AIR | 0.311284 |
F9 NW APARTMENT DIRECT AIR | 0.291846 |
F9 SE APARTMENT DIRECT AIR | 0.278061 |
F9 NE APARTMENT DIRECT AIR | 0.237123 |
F9 N1 APARTMENT DIRECT AIR | 0.163436 |
F9 N2 APARTMENT DIRECT AIR | 0.162096 |
F9 S1 APARTMENT DIRECT AIR | 0.198926 |
F9 S2 APARTMENT DIRECT AIR | 0.199777 |
T SW APARTMENT DIRECT AIR | 0.378381 |
T NW APARTMENT DIRECT AIR | 0.348590 |
T SE APARTMENT DIRECT AIR | 0.340481 |
T NE APARTMENT DIRECT AIR | 0.278204 |
T N1 APARTMENT DIRECT AIR | 0.205663 |
T N2 APARTMENT DIRECT AIR | 0.205337 |
T S1 APARTMENT DIRECT AIR | 0.271113 |
T S2 APARTMENT DIRECT AIR | 0.271937 |
Maximum Flow Rate [m3/s] | |
AIRLOOP G SW MAIN BRANCH | 0.224065 |
AIRLOOP G NW MAIN BRANCH | 0.209462 |
AIRLOOP OFFICE MAIN BRANCH | 0.337282 |
AIRLOOP G NE MAIN BRANCH | 0.171367 |
AIRLOOP G N1 MAIN BRANCH | 0.115062 |
AIRLOOP G N2 MAIN BRANCH | 0.115063 |
AIRLOOP G S1 MAIN BRANCH | 0.137534 |
AIRLOOP G S2 MAIN BRANCH | 0.143810 |
AIRLOOP F2 SW MAIN BRANCH | 0.292244 |
AIRLOOP F2 NW MAIN BRANCH | 0.271851 |
AIRLOOP F2 SE MAIN BRANCH | 0.281875 |
AIRLOOP F2 NE MAIN BRANCH | 0.209124 |
AIRLOOP F2 N1 MAIN BRANCH | 0.145222 |
AIRLOOP F2 N2 MAIN BRANCH | 0.143819 |
AIRLOOP F2 S1 MAIN BRANCH | 0.183767 |
AIRLOOP F2 S2 MAIN BRANCH | 0.186076 |
AIRLOOP F3 SW MAIN BRANCH | 0.295372 |
AIRLOOP F3 NW MAIN BRANCH | 0.275740 |
AIRLOOP F3 SE MAIN BRANCH | 0.265208 |
AIRLOOP F3 NE MAIN BRANCH | 0.213529 |
AIRLOOP F3 N1 MAIN BRANCH | 0.149692 |
AIRLOOP F3 N2 MAIN BRANCH | 0.148330 |
AIRLOOP F3 S1 MAIN BRANCH | 0.188100 |
AIRLOOP F3 S2 MAIN BRANCH | 0.189171 |
AIRLOOP F4 SW MAIN BRANCH | 0.297736 |
AIRLOOP F4 NW MAIN BRANCH | 0.278198 |
AIRLOOP F4 SE MAIN BRANCH | 0.265909 |
AIRLOOP F4 NE MAIN BRANCH | 0.215501 |
AIRLOOP F4 N1 MAIN BRANCH | 0.151944 |
AIRLOOP F4 N2 MAIN BRANCH | 0.150588 |
AIRLOOP F4 S1 MAIN BRANCH | 0.190123 |
AIRLOOP F4 S2 MAIN BRANCH | 0.191017 |
AIRLOOP M SW MAIN BRANCH | 0.301696 |
AIRLOOP M NW MAIN BRANCH | 0.282260 |
AIRLOOP M SE MAIN BRANCH | 0.269900 |
AIRLOOP M NE MAIN BRANCH | 0.219101 |
AIRLOOP M N1 MAIN BRANCH | 0.155657 |
AIRLOOP M N2 MAIN BRANCH | 0.154307 |
AIRLOOP M S1 MAIN BRANCH | 0.193669 |
AIRLOOP M S2 MAIN BRANCH | 0.194538 |
AIRLOOP F6 SW MAIN BRANCH | 0.299796 |
AIRLOOP F6 NW MAIN BRANCH | 0.280302 |
AIRLOOP F6 SE MAIN BRANCH | 0.268252 |
AIRLOOP F6 NE MAIN BRANCH | 0.216848 |
AIRLOOP F6 N1 MAIN BRANCH | 0.153666 |
AIRLOOP F6 N2 MAIN BRANCH | 0.152327 |
AIRLOOP F6 S1 MAIN BRANCH | 0.191516 |
AIRLOOP F6 S2 MAIN BRANCH | 0.192381 |
AIRLOOP F7 SW MAIN BRANCH | 0.299851 |
AIRLOOP F7 NW MAIN BRANCH | 0.280381 |
AIRLOOP F7 SE MAIN BRANCH | 0.268539 |
AIRLOOP F7 NE MAIN BRANCH | 0.216620 |
AIRLOOP F7 N1 MAIN BRANCH | 0.153614 |
AIRLOOP F7 N2 MAIN BRANCH | 0.152283 |
AIRLOOP F7 S1 MAIN BRANCH | 0.191305 |
AIRLOOP F7 S2 MAIN BRANCH | 0.192169 |
AIRLOOP F8 SW MAIN BRANCH | 0.301106 |
AIRLOOP F8 NW MAIN BRANCH | 0.281671 |
AIRLOOP F8 SE MAIN BRANCH | 0.269961 |
AIRLOOP F8 NE MAIN BRANCH | 0.223141 |
AIRLOOP F8 N1 MAIN BRANCH | 0.154777 |
AIRLOOP F8 N2 MAIN BRANCH | 0.153456 |
AIRLOOP F8 S1 MAIN BRANCH | 0.192267 |
AIRLOOP F8 S2 MAIN BRANCH | 0.193132 |
AIRLOOP F9 SW MAIN BRANCH | 0.311284 |
AIRLOOP F9 NW MAIN BRANCH | 0.291846 |
AIRLOOP F9 SE MAIN BRANCH | 0.278061 |
AIRLOOP F9 NE MAIN BRANCH | 0.237123 |
AIRLOOP F9 N1 MAIN BRANCH | 0.163436 |
AIRLOOP F9 N2 MAIN BRANCH | 0.162096 |
AIRLOOP F9 S1 MAIN BRANCH | 0.198926 |
AIRLOOP F9 S2 MAIN BRANCH | 0.199777 |
AIRLOOP T SW MAIN BRANCH | 0.378381 |
AIRLOOP T NW MAIN BRANCH | 0.348590 |
AIRLOOP T SE MAIN BRANCH | 0.340481 |
AIRLOOP T NE MAIN BRANCH | 0.278204 |
AIRLOOP T N1 MAIN BRANCH | 0.205663 |
AIRLOOP T N2 MAIN BRANCH | 0.205337 |
AIRLOOP T S1 MAIN BRANCH | 0.271113 |
AIRLOOP T S2 MAIN BRANCH | 0.271937 |
Design Supply Air Flow Rate [m3/s] | |
AIRLOOP G SW | 0.224065 |
AIRLOOP G NW | 0.209462 |
AIRLOOP OFFICE | 0.337282 |
AIRLOOP G NE | 0.171367 |
AIRLOOP G N1 | 0.115062 |
AIRLOOP G N2 | 0.115063 |
AIRLOOP G S1 | 0.137534 |
AIRLOOP G S2 | 0.143810 |
AIRLOOP F2 SW | 0.292244 |
AIRLOOP F2 NW | 0.271851 |
AIRLOOP F2 SE | 0.281875 |
AIRLOOP F2 NE | 0.209124 |
AIRLOOP F2 N1 | 0.145222 |
AIRLOOP F2 N2 | 0.143819 |
AIRLOOP F2 S1 | 0.183767 |
AIRLOOP F2 S2 | 0.186076 |
AIRLOOP F3 SW | 0.295372 |
AIRLOOP F3 NW | 0.275740 |
AIRLOOP F3 SE | 0.265208 |
AIRLOOP F3 NE | 0.213529 |
AIRLOOP F3 N1 | 0.149692 |
AIRLOOP F3 N2 | 0.148330 |
AIRLOOP F3 S1 | 0.188100 |
AIRLOOP F3 S2 | 0.189171 |
AIRLOOP F4 SW | 0.297736 |
AIRLOOP F4 NW | 0.278198 |
AIRLOOP F4 SE | 0.265909 |
AIRLOOP F4 NE | 0.215501 |
AIRLOOP F4 N1 | 0.151944 |
AIRLOOP F4 N2 | 0.150588 |
AIRLOOP F4 S1 | 0.190123 |
AIRLOOP F4 S2 | 0.191017 |
AIRLOOP M SW | 0.301696 |
AIRLOOP M NW | 0.282260 |
AIRLOOP M SE | 0.269900 |
AIRLOOP M NE | 0.219101 |
AIRLOOP M N1 | 0.155657 |
AIRLOOP M N2 | 0.154307 |
AIRLOOP M S1 | 0.193669 |
AIRLOOP M S2 | 0.194538 |
AIRLOOP F6 SW | 0.299796 |
AIRLOOP F6 NW | 0.280302 |
AIRLOOP F6 SE | 0.268252 |
AIRLOOP F6 NE | 0.216848 |
AIRLOOP F6 N1 | 0.153666 |
AIRLOOP F6 N2 | 0.152327 |
AIRLOOP F6 S1 | 0.191516 |
AIRLOOP F6 S2 | 0.192381 |
AIRLOOP F7 SW | 0.299851 |
AIRLOOP F7 NW | 0.280381 |
AIRLOOP F7 SE | 0.268539 |
AIRLOOP F7 NE | 0.216620 |
AIRLOOP F7 N1 | 0.153614 |
AIRLOOP F7 N2 | 0.152283 |
AIRLOOP F7 S1 | 0.191305 |
AIRLOOP F7 S2 | 0.192169 |
AIRLOOP F8 SW | 0.301106 |
AIRLOOP F8 NW | 0.281671 |
AIRLOOP F8 SE | 0.269961 |
AIRLOOP F8 NE | 0.223141 |
AIRLOOP F8 N1 | 0.154777 |
AIRLOOP F8 N2 | 0.153456 |
AIRLOOP F8 S1 | 0.192267 |
AIRLOOP F8 S2 | 0.193132 |
AIRLOOP F9 SW | 0.311284 |
AIRLOOP F9 NW | 0.291846 |
AIRLOOP F9 SE | 0.278061 |
AIRLOOP F9 NE | 0.237123 |
AIRLOOP F9 N1 | 0.163436 |
AIRLOOP F9 N2 | 0.162096 |
AIRLOOP F9 S1 | 0.198926 |
AIRLOOP F9 S2 | 0.199777 |
AIRLOOP T SW | 0.378381 |
AIRLOOP T NW | 0.348590 |
AIRLOOP T SE | 0.340481 |
AIRLOOP T NE | 0.278204 |
AIRLOOP T N1 | 0.205663 |
AIRLOOP T N2 | 0.205337 |
AIRLOOP T S1 | 0.271113 |
AIRLOOP T S2 | 0.271937 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
AIRLOOP G SW OA CONTROLLER | 0.224065 | 0.025952 |
AIRLOOP G NW OA CONTROLLER | 0.209462 | 0.025952 |
AIRLOOP OFFICE OA CONTROLLER | 0.337282 | 0.038103 |
AIRLOOP G NE OA CONTROLLER | 0.171367 | 0.025952 |
AIRLOOP G N1 OA CONTROLLER | 0.115062 | 0.025952 |
AIRLOOP G N2 OA CONTROLLER | 0.115063 | 0.025952 |
AIRLOOP G S1 OA CONTROLLER | 0.137534 | 0.025952 |
AIRLOOP G S2 OA CONTROLLER | 0.143810 | 0.025952 |
AIRLOOP F2 SW OA CONTROLLER | 0.292244 | 0.025952 |
AIRLOOP F2 NW OA CONTROLLER | 0.271851 | 0.025952 |
AIRLOOP F2 SE OA CONTROLLER | 0.281875 | 0.025952 |
AIRLOOP F2 NE OA CONTROLLER | 0.209124 | 0.025952 |
AIRLOOP F2 N1 OA CONTROLLER | 0.145222 | 0.025952 |
AIRLOOP F2 N2 OA CONTROLLER | 0.143819 | 0.025952 |
AIRLOOP F2 S1 OA CONTROLLER | 0.183767 | 0.025952 |
AIRLOOP F2 S2 OA CONTROLLER | 0.186076 | 0.025952 |
AIRLOOP F3 SW OA CONTROLLER | 0.295372 | 0.025952 |
AIRLOOP F3 NW OA CONTROLLER | 0.275740 | 0.025952 |
AIRLOOP F3 SE OA CONTROLLER | 0.265208 | 0.025952 |
AIRLOOP F3 NE OA CONTROLLER | 0.213529 | 0.025952 |
AIRLOOP F3 N1 OA CONTROLLER | 0.149692 | 0.025952 |
AIRLOOP F3 N2 OA CONTROLLER | 0.148330 | 0.025952 |
AIRLOOP F3 S1 OA CONTROLLER | 0.188100 | 0.025952 |
AIRLOOP F3 S2 OA CONTROLLER | 0.189171 | 0.025952 |
AIRLOOP F4 SW OA CONTROLLER | 0.297736 | 0.025952 |
AIRLOOP F4 NW OA CONTROLLER | 0.278198 | 0.025952 |
AIRLOOP F4 SE OA CONTROLLER | 0.265909 | 0.025952 |
AIRLOOP F4 NE OA CONTROLLER | 0.215501 | 0.025952 |
AIRLOOP F4 N1 OA CONTROLLER | 0.151944 | 0.025952 |
AIRLOOP F4 N2 OA CONTROLLER | 0.150588 | 0.025952 |
AIRLOOP F4 S1 OA CONTROLLER | 0.190123 | 0.025952 |
AIRLOOP F4 S2 OA CONTROLLER | 0.191017 | 0.025952 |
AIRLOOP M SW OA CONTROLLER | 0.301696 | 0.025952 |
AIRLOOP M NW OA CONTROLLER | 0.282260 | 0.025952 |
AIRLOOP M SE OA CONTROLLER | 0.269900 | 0.025952 |
AIRLOOP M NE OA CONTROLLER | 0.219101 | 0.025952 |
AIRLOOP M N1 OA CONTROLLER | 0.155657 | 0.025952 |
AIRLOOP M N2 OA CONTROLLER | 0.154307 | 0.025952 |
AIRLOOP M S1 OA CONTROLLER | 0.193669 | 0.025952 |
AIRLOOP M S2 OA CONTROLLER | 0.194538 | 0.025952 |
AIRLOOP F6 SW OA CONTROLLER | 0.299796 | 0.025952 |
AIRLOOP F6 NW OA CONTROLLER | 0.280302 | 0.025952 |
AIRLOOP F6 SE OA CONTROLLER | 0.268252 | 0.025952 |
AIRLOOP F6 NE OA CONTROLLER | 0.216848 | 0.025952 |
AIRLOOP F6 N1 OA CONTROLLER | 0.153666 | 0.025952 |
AIRLOOP F6 N2 OA CONTROLLER | 0.152327 | 0.025952 |
AIRLOOP F6 S1 OA CONTROLLER | 0.191516 | 0.025952 |
AIRLOOP F6 S2 OA CONTROLLER | 0.192381 | 0.025952 |
AIRLOOP F7 SW OA CONTROLLER | 0.299851 | 0.025952 |
AIRLOOP F7 NW OA CONTROLLER | 0.280381 | 0.025952 |
AIRLOOP F7 SE OA CONTROLLER | 0.268539 | 0.025952 |
AIRLOOP F7 NE OA CONTROLLER | 0.216620 | 0.025952 |
AIRLOOP F7 N1 OA CONTROLLER | 0.153614 | 0.025952 |
AIRLOOP F7 N2 OA CONTROLLER | 0.152283 | 0.025952 |
AIRLOOP F7 S1 OA CONTROLLER | 0.191305 | 0.025952 |
AIRLOOP F7 S2 OA CONTROLLER | 0.192169 | 0.025952 |
AIRLOOP F8 SW OA CONTROLLER | 0.301106 | 0.025952 |
AIRLOOP F8 NW OA CONTROLLER | 0.281671 | 0.025952 |
AIRLOOP F8 SE OA CONTROLLER | 0.269961 | 0.025952 |
AIRLOOP F8 NE OA CONTROLLER | 0.223141 | 0.025952 |
AIRLOOP F8 N1 OA CONTROLLER | 0.154777 | 0.025952 |
AIRLOOP F8 N2 OA CONTROLLER | 0.153456 | 0.025952 |
AIRLOOP F8 S1 OA CONTROLLER | 0.192267 | 0.025952 |
AIRLOOP F8 S2 OA CONTROLLER | 0.193132 | 0.025952 |
AIRLOOP F9 SW OA CONTROLLER | 0.311284 | 0.025952 |
AIRLOOP F9 NW OA CONTROLLER | 0.291846 | 0.025952 |
AIRLOOP F9 SE OA CONTROLLER | 0.278061 | 0.025952 |
AIRLOOP F9 NE OA CONTROLLER | 0.237123 | 0.025952 |
AIRLOOP F9 N1 OA CONTROLLER | 0.163436 | 0.025952 |
AIRLOOP F9 N2 OA CONTROLLER | 0.162096 | 0.025952 |
AIRLOOP F9 S1 OA CONTROLLER | 0.198926 | 0.025952 |
AIRLOOP F9 S2 OA CONTROLLER | 0.199777 | 0.025952 |
AIRLOOP T SW OA CONTROLLER | 0.378381 | 0.025952 |
AIRLOOP T NW OA CONTROLLER | 0.348590 | 0.025952 |
AIRLOOP T SE OA CONTROLLER | 0.340481 | 0.025952 |
AIRLOOP T NE OA CONTROLLER | 0.278204 | 0.025952 |
AIRLOOP T N1 OA CONTROLLER | 0.205663 | 0.025952 |
AIRLOOP T N2 OA CONTROLLER | 0.205337 | 0.025952 |
AIRLOOP T S1 OA CONTROLLER | 0.271113 | 0.025952 |
AIRLOOP T S2 OA CONTROLLER | 0.271937 | 0.025952 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity [W] | Rated Sensible Cooling Capacity [W] | Rated Water Flow Rate [m3/s] | |
HEAT PUMP COOLING MODE AIRLOOP G SW | 0.224065 | 4140.37 | 2697.65 | 0.000090 |
HEAT PUMP COOLING MODE AIRLOOP G NW | 0.209462 | 3911.89 | 2531.58 | 0.000085 |
HEAT PUMP COOLING MODE AIRLOOP OFFICE | 0.337282 | 6065.88 | 4013.16 | 0.000133 |
HEAT PUMP COOLING MODE AIRLOOP G NE | 0.171367 | 3398.08 | 2133.35 | 0.000074 |
HEAT PUMP COOLING MODE AIRLOOP G N1 | 0.115062 | 2483.70 | 1510.60 | 0.000054 |
HEAT PUMP COOLING MODE AIRLOOP G N2 | 0.115063 | 2495.49 | 1515.11 | 0.000055 |
HEAT PUMP COOLING MODE AIRLOOP G S1 | 0.137534 | 2818.88 | 1759.22 | 0.000062 |
HEAT PUMP COOLING MODE AIRLOOP G S2 | 0.143810 | 2909.06 | 1825.57 | 0.000064 |
HEAT PUMP COOLING MODE AIRLOOP F2 SW | 0.292244 | 5223.49 | 3452.12 | 0.000114 |
HEAT PUMP COOLING MODE AIRLOOP F2 NW | 0.271851 | 4919.15 | 3227.28 | 0.000107 |
HEAT PUMP COOLING MODE AIRLOOP F2 SE | 0.281875 | 5097.48 | 3353.19 | 0.000111 |
HEAT PUMP COOLING MODE AIRLOOP F2 NE | 0.209124 | 3965.61 | 2538.79 | 0.000087 |
HEAT PUMP COOLING MODE AIRLOOP F2 N1 | 0.145222 | 2928.72 | 1828.34 | 0.000064 |
HEAT PUMP COOLING MODE AIRLOOP F2 N2 | 0.143819 | 2907.84 | 1813.38 | 0.000064 |
HEAT PUMP COOLING MODE AIRLOOP F2 S1 | 0.183767 | 3550.23 | 2270.19 | 0.000078 |
HEAT PUMP COOLING MODE AIRLOOP F2 S2 | 0.186076 | 3583.17 | 2294.59 | 0.000078 |
HEAT PUMP COOLING MODE AIRLOOP F3 SW | 0.295372 | 5339.02 | 3506.78 | 0.000117 |
HEAT PUMP COOLING MODE AIRLOOP F3 NW | 0.275740 | 5043.96 | 3289.78 | 0.000110 |
HEAT PUMP COOLING MODE AIRLOOP F3 SE | 0.265208 | 4928.50 | 3198.05 | 0.000108 |
HEAT PUMP COOLING MODE AIRLOOP F3 NE | 0.213529 | 4100.64 | 2610.28 | 0.000090 |
HEAT PUMP COOLING MODE AIRLOOP F3 N1 | 0.149692 | 3038.46 | 1892.14 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP F3 N2 | 0.148330 | 3018.11 | 1877.60 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP F3 S1 | 0.188100 | 3652.42 | 2328.82 | 0.000080 |
HEAT PUMP COOLING MODE AIRLOOP F3 S2 | 0.189171 | 3667.67 | 2340.12 | 0.000080 |
HEAT PUMP COOLING MODE AIRLOOP F4 SW | 0.297736 | 5425.18 | 3547.88 | 0.000119 |
HEAT PUMP COOLING MODE AIRLOOP F4 NW | 0.278198 | 5130.31 | 3331.71 | 0.000112 |
HEAT PUMP COOLING MODE AIRLOOP F4 SE | 0.265909 | 4988.88 | 3221.24 | 0.000109 |
HEAT PUMP COOLING MODE AIRLOOP F4 NE | 0.215501 | 4176.10 | 2646.52 | 0.000091 |
HEAT PUMP COOLING MODE AIRLOOP F4 N1 | 0.151944 | 3098.50 | 1925.21 | 0.000068 |
HEAT PUMP COOLING MODE AIRLOOP F4 N2 | 0.150588 | 3078.14 | 1910.72 | 0.000067 |
HEAT PUMP COOLING MODE AIRLOOP F4 S1 | 0.190123 | 3711.32 | 2359.82 | 0.000081 |
HEAT PUMP COOLING MODE AIRLOOP F4 S2 | 0.191017 | 3724.07 | 2369.25 | 0.000081 |
HEAT PUMP COOLING MODE AIRLOOP M SW | 0.301696 | 5524.31 | 3602.91 | 0.000121 |
HEAT PUMP COOLING MODE AIRLOOP M NW | 0.282260 | 5230.08 | 3387.70 | 0.000114 |
HEAT PUMP COOLING MODE AIRLOOP M SE | 0.269900 | 5087.12 | 3276.40 | 0.000111 |
HEAT PUMP COOLING MODE AIRLOOP M NE | 0.219101 | 4266.51 | 2697.19 | 0.000093 |
HEAT PUMP COOLING MODE AIRLOOP M N1 | 0.155657 | 3175.15 | 1972.09 | 0.000069 |
HEAT PUMP COOLING MODE AIRLOOP M N2 | 0.154307 | 3154.84 | 1957.66 | 0.000069 |
HEAT PUMP COOLING MODE AIRLOOP M S1 | 0.193669 | 3786.74 | 2405.21 | 0.000083 |
HEAT PUMP COOLING MODE AIRLOOP M S2 | 0.194538 | 3799.14 | 2414.37 | 0.000083 |
HEAT PUMP COOLING MODE AIRLOOP F6 SW | 0.299796 | 5532.66 | 3593.88 | 0.000121 |
HEAT PUMP COOLING MODE AIRLOOP F6 NW | 0.280302 | 5236.44 | 3377.90 | 0.000114 |
HEAT PUMP COOLING MODE AIRLOOP F6 SE | 0.268252 | 5097.36 | 3269.76 | 0.000111 |
HEAT PUMP COOLING MODE AIRLOOP F6 NE | 0.216848 | 4264.65 | 2683.71 | 0.000093 |
HEAT PUMP COOLING MODE AIRLOOP F6 N1 | 0.153666 | 3163.78 | 1957.24 | 0.000069 |
HEAT PUMP COOLING MODE AIRLOOP F6 N2 | 0.152327 | 3143.50 | 1942.89 | 0.000069 |
HEAT PUMP COOLING MODE AIRLOOP F6 S1 | 0.191516 | 3775.80 | 2388.96 | 0.000082 |
HEAT PUMP COOLING MODE AIRLOOP F6 S2 | 0.192381 | 3788.19 | 2398.08 | 0.000083 |
HEAT PUMP COOLING MODE AIRLOOP F7 SW | 0.299851 | 5564.48 | 3604.19 | 0.000122 |
HEAT PUMP COOLING MODE AIRLOOP F7 NW | 0.280381 | 5267.73 | 3388.33 | 0.000115 |
HEAT PUMP COOLING MODE AIRLOOP F7 SE | 0.268539 | 5133.63 | 3283.67 | 0.000112 |
HEAT PUMP COOLING MODE AIRLOOP F7 NE | 0.216620 | 4288.45 | 2690.45 | 0.000094 |
HEAT PUMP COOLING MODE AIRLOOP F7 N1 | 0.153614 | 3178.75 | 1962.18 | 0.000069 |
HEAT PUMP COOLING MODE AIRLOOP F7 N2 | 0.152283 | 3158.50 | 1947.90 | 0.000069 |
HEAT PUMP COOLING MODE AIRLOOP F7 S1 | 0.191305 | 3790.41 | 2392.51 | 0.000083 |
HEAT PUMP COOLING MODE AIRLOOP F7 S2 | 0.192169 | 3802.82 | 2401.62 | 0.000083 |
HEAT PUMP COOLING MODE AIRLOOP F8 SW | 0.301106 | 5610.30 | 3626.22 | 0.000123 |
HEAT PUMP COOLING MODE AIRLOOP F8 NW | 0.281671 | 5313.34 | 3410.63 | 0.000116 |
HEAT PUMP COOLING MODE AIRLOOP F8 SE | 0.269961 | 5180.76 | 3307.28 | 0.000113 |
HEAT PUMP COOLING MODE AIRLOOP F8 NE | 0.223141 | 4437.62 | 2778.16 | 0.000097 |
HEAT PUMP COOLING MODE AIRLOOP F8 N1 | 0.154777 | 3210.23 | 1979.50 | 0.000070 |
HEAT PUMP COOLING MODE AIRLOOP F8 N2 | 0.153456 | 3190.06 | 1965.30 | 0.000070 |
HEAT PUMP COOLING MODE AIRLOOP F8 S1 | 0.192267 | 3820.21 | 2407.90 | 0.000083 |
HEAT PUMP COOLING MODE AIRLOOP F8 S2 | 0.193132 | 3832.67 | 2417.03 | 0.000084 |
HEAT PUMP COOLING MODE AIRLOOP F9 SW | 0.311284 | 5783.24 | 3742.31 | 0.000126 |
HEAT PUMP COOLING MODE AIRLOOP F9 NW | 0.291846 | 5486.55 | 3526.71 | 0.000120 |
HEAT PUMP COOLING MODE AIRLOOP F9 SE | 0.278061 | 5323.66 | 3401.35 | 0.000116 |
HEAT PUMP COOLING MODE AIRLOOP F9 NE | 0.237123 | 4722.30 | 2955.68 | 0.000103 |
HEAT PUMP COOLING MODE AIRLOOP F9 N1 | 0.163436 | 3353.34 | 2076.41 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F9 N2 | 0.162096 | 3332.96 | 2062.02 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F9 S1 | 0.198926 | 3934.56 | 2484.77 | 0.000086 |
HEAT PUMP COOLING MODE AIRLOOP F9 S2 | 0.199777 | 3946.82 | 2493.76 | 0.000086 |
HEAT PUMP COOLING MODE AIRLOOP T SW | 0.378381 | 6795.65 | 4472.85 | 0.000148 |
HEAT PUMP COOLING MODE AIRLOOP T NW | 0.348590 | 6351.30 | 4148.29 | 0.000139 |
HEAT PUMP COOLING MODE AIRLOOP T SE | 0.340481 | 6250.34 | 4070.40 | 0.000137 |
HEAT PUMP COOLING MODE AIRLOOP T NE | 0.278204 | 5382.81 | 3423.33 | 0.000118 |
HEAT PUMP COOLING MODE AIRLOOP T N1 | 0.205663 | 4048.81 | 2562.07 | 0.000088 |
HEAT PUMP COOLING MODE AIRLOOP T N2 | 0.205337 | 4044.25 | 2558.67 | 0.000088 |
HEAT PUMP COOLING MODE AIRLOOP T S1 | 0.271113 | 4989.41 | 3253.82 | 0.000109 |
HEAT PUMP COOLING MODE AIRLOOP T S2 | 0.271937 | 5000.97 | 3262.48 | 0.000109 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Supplemental Heating Coil Nominal Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
AIRLOOP G SW DXAC HEAT PUMP | 0.224065 | 0.224065 | 0.224065 | 0.224065 | 4140.37 | 4140.37 | 4974.82 | 1.00 |
AIRLOOP G NW DXAC HEAT PUMP | 0.209462 | 0.209462 | 0.209462 | 0.209462 | 3911.89 | 3911.89 | 4983.32 | 1.00 |
AIRLOOP OFFICE DXAC HEAT PUMP | 0.337282 | 0.337282 | 0.337282 | 0.337282 | 6065.88 | 6065.88 | 5979.01 | 1.00 |
AIRLOOP G NE DXAC HEAT PUMP | 0.171367 | 0.171367 | 0.171367 | 0.171367 | 3398.08 | 3398.08 | 4984.60 | 1.00 |
AIRLOOP G N1 DXAC HEAT PUMP | 0.115062 | 0.115062 | 0.115062 | 0.115062 | 2483.70 | 2483.70 | 3766.89 | 1.00 |
AIRLOOP G N2 DXAC HEAT PUMP | 0.115063 | 0.115063 | 0.115063 | 0.115063 | 2495.49 | 2495.49 | 3766.90 | 1.00 |
AIRLOOP G S1 DXAC HEAT PUMP | 0.137534 | 0.137534 | 0.137534 | 0.137534 | 2818.88 | 2818.88 | 3755.65 | 1.00 |
AIRLOOP G S2 DXAC HEAT PUMP | 0.143810 | 0.143810 | 0.143810 | 0.143810 | 2909.06 | 2909.06 | 3761.92 | 1.00 |
AIRLOOP F2 SW DXAC HEAT PUMP | 0.292244 | 0.292244 | 0.292244 | 0.292244 | 5223.49 | 5223.49 | 5061.34 | 1.00 |
AIRLOOP F2 NW DXAC HEAT PUMP | 0.271851 | 0.271851 | 0.271851 | 0.271851 | 4919.15 | 4919.15 | 5060.36 | 1.00 |
AIRLOOP F2 SE DXAC HEAT PUMP | 0.281875 | 0.281875 | 0.281875 | 0.281875 | 5097.48 | 5097.48 | 5075.81 | 1.00 |
AIRLOOP F2 NE DXAC HEAT PUMP | 0.209124 | 0.209124 | 0.209124 | 0.209124 | 3965.61 | 3965.61 | 5056.73 | 1.00 |
AIRLOOP F2 N1 DXAC HEAT PUMP | 0.145222 | 0.145222 | 0.145222 | 0.145222 | 2928.72 | 2928.72 | 3518.09 | 1.00 |
AIRLOOP F2 N2 DXAC HEAT PUMP | 0.143819 | 0.143819 | 0.143819 | 0.143819 | 2907.84 | 2907.84 | 3518.01 | 1.00 |
AIRLOOP F2 S1 DXAC HEAT PUMP | 0.183767 | 0.183767 | 0.183767 | 0.183767 | 3550.23 | 3550.23 | 3522.03 | 1.00 |
AIRLOOP F2 S2 DXAC HEAT PUMP | 0.186076 | 0.186076 | 0.186076 | 0.186076 | 3583.17 | 3583.17 | 3523.07 | 1.00 |
AIRLOOP F3 SW DXAC HEAT PUMP | 0.295372 | 0.295372 | 0.295372 | 0.295372 | 5339.02 | 5339.02 | 5232.35 | 1.00 |
AIRLOOP F3 NW DXAC HEAT PUMP | 0.275740 | 0.275740 | 0.275740 | 0.275740 | 5043.96 | 5043.96 | 5233.48 | 1.00 |
AIRLOOP F3 SE DXAC HEAT PUMP | 0.265208 | 0.265208 | 0.265208 | 0.265208 | 4928.50 | 4928.50 | 5227.27 | 1.00 |
AIRLOOP F3 NE DXAC HEAT PUMP | 0.213529 | 0.213529 | 0.213529 | 0.213529 | 4100.64 | 4100.64 | 5226.56 | 1.00 |
AIRLOOP F3 N1 DXAC HEAT PUMP | 0.149692 | 0.149692 | 0.149692 | 0.149692 | 3038.46 | 3038.46 | 3572.22 | 1.00 |
AIRLOOP F3 N2 DXAC HEAT PUMP | 0.148330 | 0.148330 | 0.148330 | 0.148330 | 3018.11 | 3018.11 | 3572.07 | 1.00 |
AIRLOOP F3 S1 DXAC HEAT PUMP | 0.188100 | 0.188100 | 0.188100 | 0.188100 | 3652.42 | 3652.42 | 3572.11 | 1.00 |
AIRLOOP F3 S2 DXAC HEAT PUMP | 0.189171 | 0.189171 | 0.189171 | 0.189171 | 3667.67 | 3667.67 | 3572.12 | 1.00 |
AIRLOOP F4 SW DXAC HEAT PUMP | 0.297736 | 0.297736 | 0.297736 | 0.297736 | 5425.18 | 5425.18 | 5438.29 | 1.00 |
AIRLOOP F4 NW DXAC HEAT PUMP | 0.278198 | 0.278198 | 0.278198 | 0.278198 | 5130.31 | 5130.31 | 5440.17 | 1.00 |
AIRLOOP F4 SE DXAC HEAT PUMP | 0.265909 | 0.265909 | 0.265909 | 0.265909 | 4988.88 | 4988.88 | 5429.22 | 1.00 |
AIRLOOP F4 NE DXAC HEAT PUMP | 0.215501 | 0.215501 | 0.215501 | 0.215501 | 4176.10 | 4176.10 | 5430.93 | 1.00 |
AIRLOOP F4 N1 DXAC HEAT PUMP | 0.151944 | 0.151944 | 0.151944 | 0.151944 | 3098.50 | 3098.50 | 3685.72 | 1.00 |
AIRLOOP F4 N2 DXAC HEAT PUMP | 0.150588 | 0.150588 | 0.150588 | 0.150588 | 3078.14 | 3078.14 | 3685.51 | 1.00 |
AIRLOOP F4 S1 DXAC HEAT PUMP | 0.190123 | 0.190123 | 0.190123 | 0.190123 | 3711.32 | 3711.32 | 3684.57 | 1.00 |
AIRLOOP F4 S2 DXAC HEAT PUMP | 0.191017 | 0.191017 | 0.191017 | 0.191017 | 3724.07 | 3724.07 | 3684.38 | 1.00 |
AIRLOOP M SW DXAC HEAT PUMP | 0.301696 | 0.301696 | 0.301696 | 0.301696 | 5524.31 | 5524.31 | 5598.62 | 1.00 |
AIRLOOP M NW DXAC HEAT PUMP | 0.282260 | 0.282260 | 0.282260 | 0.282260 | 5230.08 | 5230.08 | 5599.65 | 1.00 |
AIRLOOP M SE DXAC HEAT PUMP | 0.269900 | 0.269900 | 0.269900 | 0.269900 | 5087.12 | 5087.12 | 5587.60 | 1.00 |
AIRLOOP M NE DXAC HEAT PUMP | 0.219101 | 0.219101 | 0.219101 | 0.219101 | 4266.51 | 4266.51 | 5588.63 | 1.00 |
AIRLOOP M N1 DXAC HEAT PUMP | 0.155657 | 0.155657 | 0.155657 | 0.155657 | 3175.15 | 3175.15 | 3770.20 | 1.00 |
AIRLOOP M N2 DXAC HEAT PUMP | 0.154307 | 0.154307 | 0.154307 | 0.154307 | 3154.84 | 3154.84 | 3769.95 | 1.00 |
AIRLOOP M S1 DXAC HEAT PUMP | 0.193669 | 0.193669 | 0.193669 | 0.193669 | 3786.74 | 3786.74 | 3769.82 | 1.00 |
AIRLOOP M S2 DXAC HEAT PUMP | 0.194538 | 0.194538 | 0.194538 | 0.194538 | 3799.14 | 3799.14 | 3769.57 | 1.00 |
AIRLOOP F6 SW DXAC HEAT PUMP | 0.299796 | 0.299796 | 0.299796 | 0.299796 | 5532.66 | 5532.66 | 5800.24 | 1.00 |
AIRLOOP F6 NW DXAC HEAT PUMP | 0.280302 | 0.280302 | 0.280302 | 0.280302 | 5236.44 | 5236.44 | 5802.18 | 1.00 |
AIRLOOP F6 SE DXAC HEAT PUMP | 0.268252 | 0.268252 | 0.268252 | 0.268252 | 5097.36 | 5097.36 | 5787.77 | 1.00 |
AIRLOOP F6 NE DXAC HEAT PUMP | 0.216848 | 0.216848 | 0.216848 | 0.216848 | 4264.65 | 4264.65 | 5789.71 | 1.00 |
AIRLOOP F6 N1 DXAC HEAT PUMP | 0.153666 | 0.153666 | 0.153666 | 0.153666 | 3163.78 | 3163.78 | 3906.26 | 1.00 |
AIRLOOP F6 N2 DXAC HEAT PUMP | 0.152327 | 0.152327 | 0.152327 | 0.152327 | 3143.50 | 3143.50 | 3905.98 | 1.00 |
AIRLOOP F6 S1 DXAC HEAT PUMP | 0.191516 | 0.191516 | 0.191516 | 0.191516 | 3775.80 | 3775.80 | 3904.98 | 1.00 |
AIRLOOP F6 S2 DXAC HEAT PUMP | 0.192381 | 0.192381 | 0.192381 | 0.192381 | 3788.19 | 3788.19 | 3904.70 | 1.00 |
AIRLOOP F7 SW DXAC HEAT PUMP | 0.299851 | 0.299851 | 0.299851 | 0.299851 | 5564.48 | 5564.48 | 5961.20 | 1.00 |
AIRLOOP F7 NW DXAC HEAT PUMP | 0.280381 | 0.280381 | 0.280381 | 0.280381 | 5267.73 | 5267.73 | 5962.91 | 1.00 |
AIRLOOP F7 SE DXAC HEAT PUMP | 0.268539 | 0.268539 | 0.268539 | 0.268539 | 5133.63 | 5133.63 | 5947.53 | 1.00 |
AIRLOOP F7 NE DXAC HEAT PUMP | 0.216620 | 0.216620 | 0.216620 | 0.216620 | 4288.45 | 4288.45 | 5949.24 | 1.00 |
AIRLOOP F7 N1 DXAC HEAT PUMP | 0.153614 | 0.153614 | 0.153614 | 0.153614 | 3178.75 | 3178.75 | 4009.59 | 1.00 |
AIRLOOP F7 N2 DXAC HEAT PUMP | 0.152283 | 0.152283 | 0.152283 | 0.152283 | 3158.50 | 3158.50 | 4009.28 | 1.00 |
AIRLOOP F7 S1 DXAC HEAT PUMP | 0.191305 | 0.191305 | 0.191305 | 0.191305 | 3790.41 | 3790.41 | 4008.54 | 1.00 |
AIRLOOP F7 S2 DXAC HEAT PUMP | 0.192169 | 0.192169 | 0.192169 | 0.192169 | 3802.82 | 3802.82 | 4008.23 | 1.00 |
AIRLOOP F8 SW DXAC HEAT PUMP | 0.301106 | 0.301106 | 0.301106 | 0.301106 | 5610.30 | 5610.30 | 6119.02 | 1.00 |
AIRLOOP F8 NW DXAC HEAT PUMP | 0.281671 | 0.281671 | 0.281671 | 0.281671 | 5313.34 | 5313.34 | 6120.17 | 1.00 |
AIRLOOP F8 SE DXAC HEAT PUMP | 0.269961 | 0.269961 | 0.269961 | 0.269961 | 5180.76 | 5180.76 | 6104.33 | 1.00 |
AIRLOOP F8 NE DXAC HEAT PUMP | 0.223141 | 0.223141 | 0.223141 | 0.223141 | 4437.62 | 4437.62 | 6105.48 | 1.00 |
AIRLOOP F8 N1 DXAC HEAT PUMP | 0.154777 | 0.154777 | 0.154777 | 0.154777 | 3210.23 | 3210.23 | 4115.49 | 1.00 |
AIRLOOP F8 N2 DXAC HEAT PUMP | 0.153456 | 0.153456 | 0.153456 | 0.153456 | 3190.06 | 3190.06 | 4115.16 | 1.00 |
AIRLOOP F8 S1 DXAC HEAT PUMP | 0.192267 | 0.192267 | 0.192267 | 0.192267 | 3820.21 | 3820.21 | 4114.99 | 1.00 |
AIRLOOP F8 S2 DXAC HEAT PUMP | 0.193132 | 0.193132 | 0.193132 | 0.193132 | 3832.67 | 3832.67 | 4114.66 | 1.00 |
AIRLOOP F9 SW DXAC HEAT PUMP | 0.311284 | 0.311284 | 0.311284 | 0.311284 | 5783.24 | 5783.24 | 6426.33 | 1.00 |
AIRLOOP F9 NW DXAC HEAT PUMP | 0.291846 | 0.291846 | 0.291846 | 0.291846 | 5486.55 | 5486.55 | 6423.71 | 1.00 |
AIRLOOP F9 SE DXAC HEAT PUMP | 0.278061 | 0.278061 | 0.278061 | 0.278061 | 5323.66 | 5323.66 | 6410.61 | 1.00 |
AIRLOOP F9 NE DXAC HEAT PUMP | 0.237123 | 0.237123 | 0.237123 | 0.237123 | 4722.30 | 4722.30 | 6407.99 | 1.00 |
AIRLOOP F9 N1 DXAC HEAT PUMP | 0.163436 | 0.163436 | 0.163436 | 0.163436 | 3353.34 | 3353.34 | 4361.60 | 1.00 |
AIRLOOP F9 N2 DXAC HEAT PUMP | 0.162096 | 0.162096 | 0.162096 | 0.162096 | 3332.96 | 3332.96 | 4361.25 | 1.00 |
AIRLOOP F9 S1 DXAC HEAT PUMP | 0.198926 | 0.198926 | 0.198926 | 0.198926 | 3934.56 | 3934.56 | 4364.47 | 1.00 |
AIRLOOP F9 S2 DXAC HEAT PUMP | 0.199777 | 0.199777 | 0.199777 | 0.199777 | 3946.82 | 3946.82 | 4364.12 | 1.00 |
AIRLOOP T SW DXAC HEAT PUMP | 0.378381 | 0.378381 | 0.378381 | 0.378381 | 6795.65 | 6795.65 | 7306.56 | 1.00 |
AIRLOOP T NW DXAC HEAT PUMP | 0.348590 | 0.348590 | 0.348590 | 0.348590 | 6351.30 | 6351.30 | 7312.16 | 1.00 |
AIRLOOP T SE DXAC HEAT PUMP | 0.340481 | 0.340481 | 0.340481 | 0.340481 | 6250.34 | 6250.34 | 7291.30 | 1.00 |
AIRLOOP T NE DXAC HEAT PUMP | 0.278204 | 0.278204 | 0.278204 | 0.278204 | 5382.81 | 5382.81 | 7296.89 | 1.00 |
AIRLOOP T N1 DXAC HEAT PUMP | 0.205663 | 0.205663 | 0.205663 | 0.205663 | 4048.81 | 4048.81 | 5280.17 | 1.00 |
AIRLOOP T N2 DXAC HEAT PUMP | 0.205337 | 0.205337 | 0.205337 | 0.205337 | 4044.25 | 4044.25 | 5279.80 | 1.00 |
AIRLOOP T S1 DXAC HEAT PUMP | 0.271113 | 0.271113 | 0.271113 | 0.271113 | 4989.41 | 4989.41 | 5271.94 | 1.00 |
AIRLOOP T S2 DXAC HEAT PUMP | 0.271937 | 0.271937 | 0.271937 | 0.271937 | 5000.97 | 5000.97 | 5271.57 | 1.00 |
Maximum Flow Rate [m3/s] | |
AIRLOOP G SW SUPPLY FAN | 0.224065 |
AIRLOOP G NW SUPPLY FAN | 0.209462 |
AIRLOOP OFFICE SUPPLY FAN | 0.337282 |
AIRLOOP G NE SUPPLY FAN | 0.171367 |
AIRLOOP G N1 SUPPLY FAN | 0.115062 |
AIRLOOP G N2 SUPPLY FAN | 0.115063 |
AIRLOOP G S1 SUPPLY FAN | 0.137534 |
AIRLOOP G S2 SUPPLY FAN | 0.143810 |
AIRLOOP F2 SW SUPPLY FAN | 0.292244 |
AIRLOOP F2 NW SUPPLY FAN | 0.271851 |
AIRLOOP F2 SE SUPPLY FAN | 0.281875 |
AIRLOOP F2 NE SUPPLY FAN | 0.209124 |
AIRLOOP F2 N1 SUPPLY FAN | 0.145222 |
AIRLOOP F2 N2 SUPPLY FAN | 0.143819 |
AIRLOOP F2 S1 SUPPLY FAN | 0.183767 |
AIRLOOP F2 S2 SUPPLY FAN | 0.186076 |
AIRLOOP F3 SW SUPPLY FAN | 0.295372 |
AIRLOOP F3 NW SUPPLY FAN | 0.275740 |
AIRLOOP F3 SE SUPPLY FAN | 0.265208 |
AIRLOOP F3 NE SUPPLY FAN | 0.213529 |
AIRLOOP F3 N1 SUPPLY FAN | 0.149692 |
AIRLOOP F3 N2 SUPPLY FAN | 0.148330 |
AIRLOOP F3 S1 SUPPLY FAN | 0.188100 |
AIRLOOP F3 S2 SUPPLY FAN | 0.189171 |
AIRLOOP F4 SW SUPPLY FAN | 0.297736 |
AIRLOOP F4 NW SUPPLY FAN | 0.278198 |
AIRLOOP F4 SE SUPPLY FAN | 0.265909 |
AIRLOOP F4 NE SUPPLY FAN | 0.215501 |
AIRLOOP F4 N1 SUPPLY FAN | 0.151944 |
AIRLOOP F4 N2 SUPPLY FAN | 0.150588 |
AIRLOOP F4 S1 SUPPLY FAN | 0.190123 |
AIRLOOP F4 S2 SUPPLY FAN | 0.191017 |
AIRLOOP M SW SUPPLY FAN | 0.301696 |
AIRLOOP M NW SUPPLY FAN | 0.282260 |
AIRLOOP M SE SUPPLY FAN | 0.269900 |
AIRLOOP M NE SUPPLY FAN | 0.219101 |
AIRLOOP M N1 SUPPLY FAN | 0.155657 |
AIRLOOP M N2 SUPPLY FAN | 0.154307 |
AIRLOOP M S1 SUPPLY FAN | 0.193669 |
AIRLOOP M S2 SUPPLY FAN | 0.194538 |
AIRLOOP F6 SW SUPPLY FAN | 0.299796 |
AIRLOOP F6 NW SUPPLY FAN | 0.280302 |
AIRLOOP F6 SE SUPPLY FAN | 0.268252 |
AIRLOOP F6 NE SUPPLY FAN | 0.216848 |
AIRLOOP F6 N1 SUPPLY FAN | 0.153666 |
AIRLOOP F6 N2 SUPPLY FAN | 0.152327 |
AIRLOOP F6 S1 SUPPLY FAN | 0.191516 |
AIRLOOP F6 S2 SUPPLY FAN | 0.192381 |
AIRLOOP F7 SW SUPPLY FAN | 0.299851 |
AIRLOOP F7 NW SUPPLY FAN | 0.280381 |
AIRLOOP F7 SE SUPPLY FAN | 0.268539 |
AIRLOOP F7 NE SUPPLY FAN | 0.216620 |
AIRLOOP F7 N1 SUPPLY FAN | 0.153614 |
AIRLOOP F7 N2 SUPPLY FAN | 0.152283 |
AIRLOOP F7 S1 SUPPLY FAN | 0.191305 |
AIRLOOP F7 S2 SUPPLY FAN | 0.192169 |
AIRLOOP F8 SW SUPPLY FAN | 0.301106 |
AIRLOOP F8 NW SUPPLY FAN | 0.281671 |
AIRLOOP F8 SE SUPPLY FAN | 0.269961 |
AIRLOOP F8 NE SUPPLY FAN | 0.223141 |
AIRLOOP F8 N1 SUPPLY FAN | 0.154777 |
AIRLOOP F8 N2 SUPPLY FAN | 0.153456 |
AIRLOOP F8 S1 SUPPLY FAN | 0.192267 |
AIRLOOP F8 S2 SUPPLY FAN | 0.193132 |
AIRLOOP F9 SW SUPPLY FAN | 0.311284 |
AIRLOOP F9 NW SUPPLY FAN | 0.291846 |
AIRLOOP F9 SE SUPPLY FAN | 0.278061 |
AIRLOOP F9 NE SUPPLY FAN | 0.237123 |
AIRLOOP F9 N1 SUPPLY FAN | 0.163436 |
AIRLOOP F9 N2 SUPPLY FAN | 0.162096 |
AIRLOOP F9 S1 SUPPLY FAN | 0.198926 |
AIRLOOP F9 S2 SUPPLY FAN | 0.199777 |
AIRLOOP T SW SUPPLY FAN | 0.378381 |
AIRLOOP T NW SUPPLY FAN | 0.348590 |
AIRLOOP T SE SUPPLY FAN | 0.340481 |
AIRLOOP T NE SUPPLY FAN | 0.278204 |
AIRLOOP T N1 SUPPLY FAN | 0.205663 |
AIRLOOP T N2 SUPPLY FAN | 0.205337 |
AIRLOOP T S1 SUPPLY FAN | 0.271113 |
AIRLOOP T S2 SUPPLY FAN | 0.271937 |
Rated Air Flow Rate [m3/s] | Rated Heating Capacity [W] | Rated Water Flow Rate [m3/s] | |
HEAT PUMP HEATING MODE AIRLOOP G SW | 0.224065 | 4140.37 | 0.000090 |
HEAT PUMP HEATING MODE AIRLOOP G NW | 0.209462 | 3911.89 | 0.000085 |
HEAT PUMP HEATING MODE AIRLOOP OFFICE | 0.337282 | 6065.88 | 0.000133 |
HEAT PUMP HEATING MODE AIRLOOP G NE | 0.171367 | 3398.08 | 0.000074 |
HEAT PUMP HEATING MODE AIRLOOP G N1 | 0.115062 | 2483.70 | 0.000054 |
HEAT PUMP HEATING MODE AIRLOOP G N2 | 0.115063 | 2495.49 | 0.000055 |
HEAT PUMP HEATING MODE AIRLOOP G S1 | 0.137534 | 2818.88 | 0.000062 |
HEAT PUMP HEATING MODE AIRLOOP G S2 | 0.143810 | 2909.06 | 0.000064 |
HEAT PUMP HEATING MODE AIRLOOP F2 SW | 0.292244 | 5223.49 | 0.000114 |
HEAT PUMP HEATING MODE AIRLOOP F2 NW | 0.271851 | 4919.15 | 0.000107 |
HEAT PUMP HEATING MODE AIRLOOP F2 SE | 0.281875 | 5097.48 | 0.000111 |
HEAT PUMP HEATING MODE AIRLOOP F2 NE | 0.209124 | 3965.61 | 0.000087 |
HEAT PUMP HEATING MODE AIRLOOP F2 N1 | 0.145222 | 2928.72 | 0.000064 |
HEAT PUMP HEATING MODE AIRLOOP F2 N2 | 0.143819 | 2907.84 | 0.000064 |
HEAT PUMP HEATING MODE AIRLOOP F2 S1 | 0.183767 | 3550.23 | 0.000078 |
HEAT PUMP HEATING MODE AIRLOOP F2 S2 | 0.186076 | 3583.17 | 0.000078 |
HEAT PUMP HEATING MODE AIRLOOP F3 SW | 0.295372 | 5339.02 | 0.000117 |
HEAT PUMP HEATING MODE AIRLOOP F3 NW | 0.275740 | 5043.96 | 0.000110 |
HEAT PUMP HEATING MODE AIRLOOP F3 SE | 0.265208 | 4928.50 | 0.000108 |
HEAT PUMP HEATING MODE AIRLOOP F3 NE | 0.213529 | 4100.64 | 0.000090 |
HEAT PUMP HEATING MODE AIRLOOP F3 N1 | 0.149692 | 3038.46 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP F3 N2 | 0.148330 | 3018.11 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP F3 S1 | 0.188100 | 3652.42 | 0.000080 |
HEAT PUMP HEATING MODE AIRLOOP F3 S2 | 0.189171 | 3667.67 | 0.000080 |
HEAT PUMP HEATING MODE AIRLOOP F4 SW | 0.297736 | 5425.18 | 0.000119 |
HEAT PUMP HEATING MODE AIRLOOP F4 NW | 0.278198 | 5130.31 | 0.000112 |
HEAT PUMP HEATING MODE AIRLOOP F4 SE | 0.265909 | 4988.88 | 0.000109 |
HEAT PUMP HEATING MODE AIRLOOP F4 NE | 0.215501 | 4176.10 | 0.000091 |
HEAT PUMP HEATING MODE AIRLOOP F4 N1 | 0.151944 | 3098.50 | 0.000068 |
HEAT PUMP HEATING MODE AIRLOOP F4 N2 | 0.150588 | 3078.14 | 0.000067 |
HEAT PUMP HEATING MODE AIRLOOP F4 S1 | 0.190123 | 3711.32 | 0.000081 |
HEAT PUMP HEATING MODE AIRLOOP F4 S2 | 0.191017 | 3724.07 | 0.000081 |
HEAT PUMP HEATING MODE AIRLOOP M SW | 0.301696 | 5524.31 | 0.000121 |
HEAT PUMP HEATING MODE AIRLOOP M NW | 0.282260 | 5230.08 | 0.000114 |
HEAT PUMP HEATING MODE AIRLOOP M SE | 0.269900 | 5087.12 | 0.000111 |
HEAT PUMP HEATING MODE AIRLOOP M NE | 0.219101 | 4266.51 | 0.000093 |
HEAT PUMP HEATING MODE AIRLOOP M N1 | 0.155657 | 3175.15 | 0.000069 |
HEAT PUMP HEATING MODE AIRLOOP M N2 | 0.154307 | 3154.84 | 0.000069 |
HEAT PUMP HEATING MODE AIRLOOP M S1 | 0.193669 | 3786.74 | 0.000083 |
HEAT PUMP HEATING MODE AIRLOOP M S2 | 0.194538 | 3799.14 | 0.000083 |
HEAT PUMP HEATING MODE AIRLOOP F6 SW | 0.299796 | 5532.66 | 0.000121 |
HEAT PUMP HEATING MODE AIRLOOP F6 NW | 0.280302 | 5236.44 | 0.000114 |
HEAT PUMP HEATING MODE AIRLOOP F6 SE | 0.268252 | 5097.36 | 0.000111 |
HEAT PUMP HEATING MODE AIRLOOP F6 NE | 0.216848 | 4264.65 | 0.000093 |
HEAT PUMP HEATING MODE AIRLOOP F6 N1 | 0.153666 | 3163.78 | 0.000069 |
HEAT PUMP HEATING MODE AIRLOOP F6 N2 | 0.152327 | 3143.50 | 0.000069 |
HEAT PUMP HEATING MODE AIRLOOP F6 S1 | 0.191516 | 3775.80 | 0.000082 |
HEAT PUMP HEATING MODE AIRLOOP F6 S2 | 0.192381 | 3788.19 | 0.000083 |
HEAT PUMP HEATING MODE AIRLOOP F7 SW | 0.299851 | 5564.48 | 0.000122 |
HEAT PUMP HEATING MODE AIRLOOP F7 NW | 0.280381 | 5267.73 | 0.000115 |
HEAT PUMP HEATING MODE AIRLOOP F7 SE | 0.268539 | 5133.63 | 0.000112 |
HEAT PUMP HEATING MODE AIRLOOP F7 NE | 0.216620 | 4288.45 | 0.000094 |
HEAT PUMP HEATING MODE AIRLOOP F7 N1 | 0.153614 | 3178.75 | 0.000069 |
HEAT PUMP HEATING MODE AIRLOOP F7 N2 | 0.152283 | 3158.50 | 0.000069 |
HEAT PUMP HEATING MODE AIRLOOP F7 S1 | 0.191305 | 3790.41 | 0.000083 |
HEAT PUMP HEATING MODE AIRLOOP F7 S2 | 0.192169 | 3802.82 | 0.000083 |
HEAT PUMP HEATING MODE AIRLOOP F8 SW | 0.301106 | 5610.30 | 0.000123 |
HEAT PUMP HEATING MODE AIRLOOP F8 NW | 0.281671 | 5313.34 | 0.000116 |
HEAT PUMP HEATING MODE AIRLOOP F8 SE | 0.269961 | 5180.76 | 0.000113 |
HEAT PUMP HEATING MODE AIRLOOP F8 NE | 0.223141 | 4437.62 | 0.000097 |
HEAT PUMP HEATING MODE AIRLOOP F8 N1 | 0.154777 | 3210.23 | 0.000070 |
HEAT PUMP HEATING MODE AIRLOOP F8 N2 | 0.153456 | 3190.06 | 0.000070 |
HEAT PUMP HEATING MODE AIRLOOP F8 S1 | 0.192267 | 3820.21 | 0.000083 |
HEAT PUMP HEATING MODE AIRLOOP F8 S2 | 0.193132 | 3832.67 | 0.000084 |
HEAT PUMP HEATING MODE AIRLOOP F9 SW | 0.311284 | 5783.24 | 0.000126 |
HEAT PUMP HEATING MODE AIRLOOP F9 NW | 0.291846 | 5486.55 | 0.000120 |
HEAT PUMP HEATING MODE AIRLOOP F9 SE | 0.278061 | 5323.66 | 0.000116 |
HEAT PUMP HEATING MODE AIRLOOP F9 NE | 0.237123 | 4722.30 | 0.000103 |
HEAT PUMP HEATING MODE AIRLOOP F9 N1 | 0.163436 | 3353.34 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F9 N2 | 0.162096 | 3332.96 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F9 S1 | 0.198926 | 3934.56 | 0.000086 |
HEAT PUMP HEATING MODE AIRLOOP F9 S2 | 0.199777 | 3946.82 | 0.000086 |
HEAT PUMP HEATING MODE AIRLOOP T SW | 0.378381 | 6795.65 | 0.000148 |
HEAT PUMP HEATING MODE AIRLOOP T NW | 0.348590 | 6351.30 | 0.000139 |
HEAT PUMP HEATING MODE AIRLOOP T SE | 0.340481 | 6250.34 | 0.000137 |
HEAT PUMP HEATING MODE AIRLOOP T NE | 0.278204 | 5382.81 | 0.000118 |
HEAT PUMP HEATING MODE AIRLOOP T N1 | 0.205663 | 4048.81 | 0.000088 |
HEAT PUMP HEATING MODE AIRLOOP T N2 | 0.205337 | 4044.25 | 0.000088 |
HEAT PUMP HEATING MODE AIRLOOP T S1 | 0.271113 | 4989.41 | 0.000109 |
HEAT PUMP HEATING MODE AIRLOOP T S2 | 0.271937 | 5000.97 | 0.000109 |
Nominal Capacity [W] | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW | 4974.82 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW | 4983.32 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE | 5979.01 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE | 4984.60 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 | 3766.89 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 | 3766.90 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 | 3755.65 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 | 3761.92 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW | 5061.34 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW | 5060.36 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE | 5075.81 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE | 5056.73 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 | 3518.09 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 | 3518.01 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 | 3522.03 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 | 3523.07 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW | 5232.35 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW | 5233.48 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE | 5227.27 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE | 5226.56 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 | 3572.22 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 | 3572.07 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 | 3572.11 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 | 3572.12 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW | 5438.29 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW | 5440.17 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE | 5429.22 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE | 5430.93 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 | 3685.72 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 | 3685.51 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 | 3684.57 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 | 3684.38 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW | 5598.62 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW | 5599.65 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE | 5587.60 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE | 5588.63 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 | 3770.20 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 | 3769.95 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 | 3769.82 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 | 3769.57 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW | 5800.24 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW | 5802.18 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE | 5787.77 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE | 5789.71 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 | 3906.26 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 | 3905.98 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 | 3904.98 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 | 3904.70 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW | 5961.20 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW | 5962.91 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE | 5947.53 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE | 5949.24 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 | 4009.59 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 | 4009.28 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 | 4008.54 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 | 4008.23 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW | 6119.02 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW | 6120.17 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE | 6104.33 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE | 6105.48 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 | 4115.49 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 | 4115.16 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 | 4114.99 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 | 4114.66 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW | 6426.33 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW | 6423.71 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE | 6410.61 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE | 6407.99 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 | 4361.60 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 | 4361.25 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 | 4364.47 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 | 4364.12 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW | 7306.56 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW | 7312.16 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE | 7291.30 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE | 7296.89 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 | 5280.17 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 | 5279.80 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 | 5271.94 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 | 5271.57 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
SHWSYS1 | 0.000289 | 0.325214 |
SINGLE WATER PLANT LOOP | 0.007472 | 8.41 |
Design Water Flow Rate [m3/s] | |
CENTRAL BOILER | 0.007472 |
Use Side Design Flow Rate [m3/s] | |
SHWSYS1 WATER HEATER | 0.000289 |
Design Water Flow Rate [m3/s] | Fan Power at Design Air Flow Rate [W] | Design Air Flow Rate [m3/s] | U-Factor Times Area Value at Design Air Flow Rate [W/C] | |
CENTRAL TOWER | 0.007472 | 3607.28 | 9.72 | 10928.40 |
Rated Flow Rate [m3/s] | Rated Power Consumption [W] | |
SHWSYS1 PUMP | 0.000289 | 36.93 |
PLANT CIRC PUMP | 0.007472 | 2386.30 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW3 | |
G WWALL SWA | GWINDOW2 | |
G NWALL NWA | GWINDOW4 | |
G WWALL NWA | GWINDOW6 | |
G SWALL SEA | GWINDOW1 | |
G EWALL SEA | GWINDOW8 | |
G NWALL NEA | GWINDOW5 | |
G EWALL NEA | GWINDOW7 | |
G NWALL N1A | GWINDOW9 | |
G NWALL N2A | GWINDOW10 | |
G SWALL S1A | GWINDOW11 | |
G SWALL S2A | GWINDOW12 | |
G WWALL C | GWINDOW13 | |
G EWALL C | ENTRANCE DOOR | |
F2 WWALL SWA | F2WINDOW2 | |
F2 SWALL SWA | F2WINDOW3 | |
F2 NWALL NWA | F2WINDOW4 | |
F2 WWALL NWA | F2WINDOW6 | |
F2 EWALL SEA | F2WINDOW8 | |
F2 SWALL SEA | F2WINDOW1 | |
F2 NWALL NEA | F2WINDOW5 | |
F2 EWALL NEA | F2WINDOW7 | |
F2 NWALL N1A | F2WINDOW9 | |
F2 NWALL N2A | F2WINDOW10 | |
F2 SWALL S1A | F2WINDOW11 | |
F2 SWALL S2A | F2WINDOW12 | |
F2 WWALL C | F2WINDOW13 | |
F2 EWALL C | F2WINDOW14 | |
F3 WWALL SWA | F3WINDOW2 | |
F3 SWALL SWA | F3WINDOW3 | |
F3 NWALL NWA | F3WINDOW4 | |
F3 WWALL NWA | F3WINDOW6 | |
F3 EWALL SEA | F3WINDOW8 | |
F3 SWALL SEA | F3WINDOW1 | |
F3 NWALL NEA | F3WINDOW5 | |
F3 EWALL NEA | F3WINDOW7 | |
F3 NWALL N1A | F3WINDOW9 | |
F3 NWALL N2A | F3WINDOW10 | |
F3 SWALL S1A | F3WINDOW11 | |
F3 SWALL S2A | F3WINDOW12 | |
F3 WWALL C | F3WINDOW13 | |
F3 EWALL C | F3WINDOW14 | |
F4 WWALL SWA | F4WINDOW2 | |
F4 SWALL SWA | F4WINDOW3 | |
F4 NWALL NWA | F4WINDOW4 | |
F4 WWALL NWA | F4WINDOW6 | |
F4 EWALL SEA | F4WINDOW8 | |
F4 SWALL SEA | F4WINDOW1 | |
F4 NWALL NEA | F4WINDOW5 | |
F4 EWALL NEA | F4WINDOW7 | |
F4 NWALL N1A | F4WINDOW9 | |
F4 NWALL N2A | F4WINDOW10 | |
F4 SWALL S1A | F4WINDOW11 | |
F4 SWALL S2A | F4WINDOW12 | |
F4 WWALL C | F4WINDOW13 | |
F4 EWALL C | F4WINDOW14 | |
M WWALL SWA | MWINDOW2 | |
M SWALL SWA | MWINDOW3 | |
M NWALL NWA | MWINDOW4 | |
M WWALL NWA | MWINDOW6 | |
M EWALL SEA | MWINDOW8 | |
M SWALL SEA | MWINDOW1 | |
M NWALL NEA | MWINDOW5 | |
M EWALL NEA | MWINDOW7 | |
M NWALL N1A | MWINDOW9 | |
M NWALL N2A | MWINDOW10 | |
M SWALL S1A | MWINDOW11 | |
M SWALL S2A | MWINDOW12 | |
M WWALL C | MWINDOW13 | |
M EWALL C | MWINDOW14 | |
F6 WWALL SWA | F6WINDOW2 | |
F6 SWALL SWA | F6WINDOW3 | |
F6 NWALL NWA | F6WINDOW4 | |
F6 WWALL NWA | F6WINDOW6 | |
F6 EWALL SEA | F6WINDOW8 | |
F6 SWALL SEA | F6WINDOW1 | |
F6 NWALL NEA | F6WINDOW5 | |
F6 EWALL NEA | F6WINDOW7 | |
F6 NWALL N1A | F6WINDOW9 | |
F6 NWALL N2A | F6WINDOW10 | |
F6 SWALL S1A | F6WINDOW11 | |
F6 SWALL S2A | F6WINDOW12 | |
F6 WWALL C | F6WINDOW13 | |
F6 EWALL C | F6WINDOW14 | |
F7 WWALL SWA | F7WINDOW2 | |
F7 SWALL SWA | F7WINDOW3 | |
F7 NWALL NWA | F7WINDOW4 | |
F7 WWALL NWA | F7WINDOW6 | |
F7 EWALL SEA | F7WINDOW8 | |
F7 SWALL SEA | F7WINDOW1 | |
F7 NWALL NEA | F7WINDOW5 | |
F7 EWALL NEA | F7WINDOW7 | |
F7 NWALL N1A | F7WINDOW9 | |
F7 NWALL N2A | F7WINDOW10 | |
F7 SWALL S1A | F7WINDOW11 | |
F7 SWALL S2A | F7WINDOW12 | |
F7 WWALL C | F7WINDOW13 | |
F7 EWALL C | F7WINDOW14 | |
F8 WWALL SWA | F8WINDOW2 | |
F8 SWALL SWA | F8WINDOW3 | |
F8 NWALL NWA | F8WINDOW4 | |
F8 WWALL NWA | F8WINDOW6 | |
F8 EWALL SEA | F8WINDOW8 | |
F8 SWALL SEA | F8WINDOW1 | |
F8 NWALL NEA | F8WINDOW5 | |
F8 EWALL NEA | F8WINDOW7 | |
F8 NWALL N1A | F8WINDOW9 | |
F8 NWALL N2A | F8WINDOW10 | |
F8 SWALL S1A | F8WINDOW11 | |
F8 SWALL S2A | F8WINDOW12 | |
F8 WWALL C | F8WINDOW13 | |
F8 EWALL C | F8WINDOW14 | |
F9 WWALL SWA | F9WINDOW2 | |
F9 SWALL SWA | F9WINDOW3 | |
F9 NWALL NWA | F9WINDOW4 | |
F9 WWALL NWA | F9WINDOW6 | |
F9 EWALL SEA | F9WINDOW8 | |
F9 SWALL SEA | F9WINDOW1 | |
F9 NWALL NEA | F9WINDOW5 | |
F9 EWALL NEA | F9WINDOW7 | |
F9 NWALL N1A | F9WINDOW9 | |
F9 NWALL N2A | F9WINDOW10 | |
F9 SWALL S1A | F9WINDOW11 | |
F9 SWALL S2A | F9WINDOW12 | |
F9 WWALL C | F9WINDOW13 | |
F9 EWALL C | F9WINDOW14 | |
T WWALL SWA | TWINDOW2 | |
T SWALL SWA | TWINDOW3 | |
T NWALL NWA | TWINDOW4 | |
T WWALL NWA | TWINDOW6 | |
T EWALL SEA | TWINDOW8 | |
T SWALL SEA | TWINDOW1 | |
T NWALL NEA | TWINDOW5 | |
T EWALL NEA | TWINDOW7 | |
T NWALL N1A | TWINDOW9 | |
T NWALL N2A | TWINDOW10 | |
T SWALL S1A | TWINDOW11 | |
T SWALL S2A | TWINDOW12 | |
T WWALL C | TWINDOW13 | |
T EWALL C | TWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.73 | -4.6 |
February | 21.75 | -2.5 |
March | 21.90 | 3.82 |
April | 22.47 | 9.95 |
May | 23.17 | 15.31 |
June | 24.14 | 21.11 |
July | 24.34 | 24.13 |
August | 24.30 | 21.78 |
September | 24.04 | 18.14 |
October | 22.63 | 10.98 |
November | 21.98 | 4.73 |
December | 21.71 | -3.7 |
Annual Sum or Average | 22.85 | 9.99 |
Minimum of Months | 21.71 | -4.6 |
Maximum of Months | 24.34 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.73 | 3.82 |
April | 22.29 | 9.95 |
May | 23.02 | 15.31 |
June | 24.13 | 21.11 |
July | 24.34 | 24.13 |
August | 24.29 | 21.78 |
September | 23.88 | 18.14 |
October | 22.07 | 10.98 |
November | 21.81 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.73 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.34 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.80 | -4.6 |
February | 21.88 | -2.5 |
March | 22.23 | 3.82 |
April | 22.71 | 9.95 |
May | 23.62 | 15.31 |
June | 24.32 | 21.11 |
July | 24.40 | 24.13 |
August | 24.39 | 21.78 |
September | 24.26 | 18.14 |
October | 23.09 | 10.98 |
November | 22.37 | 4.73 |
December | 21.80 | -3.7 |
Annual Sum or Average | 23.08 | 9.99 |
Minimum of Months | 21.80 | -4.6 |
Maximum of Months | 24.40 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.71 | 3.82 |
April | 22.25 | 9.95 |
May | 22.99 | 15.31 |
June | 24.11 | 21.11 |
July | 24.34 | 24.13 |
August | 24.29 | 21.78 |
September | 23.85 | 18.14 |
October | 22.01 | 10.98 |
November | 21.78 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.71 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.34 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.71 | 3.82 |
April | 22.19 | 9.95 |
May | 22.80 | 15.31 |
June | 24.05 | 21.11 |
July | 24.32 | 24.13 |
August | 24.25 | 21.78 |
September | 23.79 | 18.14 |
October | 21.99 | 10.98 |
November | 21.80 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.67 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.32 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.71 | 3.82 |
April | 22.19 | 9.95 |
May | 22.80 | 15.31 |
June | 24.05 | 21.11 |
July | 24.32 | 24.13 |
August | 24.25 | 21.78 |
September | 23.79 | 18.14 |
October | 21.99 | 10.98 |
November | 21.80 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.67 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.32 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.73 | -4.6 |
February | 21.75 | -2.5 |
March | 21.89 | 3.82 |
April | 22.40 | 9.95 |
May | 23.04 | 15.31 |
June | 24.11 | 21.11 |
July | 24.33 | 24.13 |
August | 24.29 | 21.78 |
September | 24.06 | 18.14 |
October | 22.73 | 10.98 |
November | 22.04 | 4.73 |
December | 21.72 | -3.7 |
Annual Sum or Average | 22.85 | 9.99 |
Minimum of Months | 21.72 | -4.6 |
Maximum of Months | 24.33 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.74 | -4.6 |
February | 21.76 | -2.5 |
March | 21.92 | 3.82 |
April | 22.42 | 9.95 |
May | 23.09 | 15.31 |
June | 24.13 | 21.11 |
July | 24.33 | 24.13 |
August | 24.30 | 21.78 |
September | 24.09 | 18.14 |
October | 22.79 | 10.98 |
November | 22.08 | 4.73 |
December | 21.72 | -3.7 |
Annual Sum or Average | 22.87 | 9.99 |
Minimum of Months | 21.72 | -4.6 |
Maximum of Months | 24.33 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 13.96 | -4.6 |
February | 14.67 | -2.5 |
March | 16.83 | 3.82 |
April | 19.13 | 9.95 |
May | 21.71 | 15.31 |
June | 24.52 | 21.11 |
July | 25.69 | 24.13 |
August | 24.83 | 21.78 |
September | 23.46 | 18.14 |
October | 19.74 | 10.98 |
November | 17.12 | 4.73 |
December | 14.27 | -3.7 |
Annual Sum or Average | 19.69 | 9.99 |
Minimum of Months | 13.96 | -4.6 |
Maximum of Months | 25.69 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F2 SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.75 | -4.6 |
February | 21.80 | -2.5 |
March | 22.10 | 3.82 |
April | 22.77 | 9.95 |
May | 23.92 | 15.31 |
June | 24.29 | 21.11 |
July | 24.38 | 24.13 |
August | 24.36 | 21.78 |
September | 24.24 | 18.14 |
October | 23.20 | 10.98 |
November | 22.27 | 4.73 |
December | 21.73 | -3.7 |
Annual Sum or Average | 23.07 | 9.99 |
Minimum of Months | 21.73 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F2 NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.76 | 3.82 |
April | 22.50 | 9.95 |
May | 23.72 | 15.31 |
June | 24.27 | 21.11 |
July | 24.37 | 24.13 |
August | 24.35 | 21.78 |
September | 24.08 | 18.14 |
October | 22.36 | 10.98 |
November | 21.97 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.88 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F2 SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.76 | -4.6 |
February | 21.81 | -2.5 |
March | 22.20 | 3.82 |
April | 22.83 | 9.95 |
May | 24.02 | 15.31 |
June | 24.31 | 21.11 |
July | 24.38 | 24.13 |
August | 24.37 | 21.78 |
September | 24.29 | 18.14 |
October | 23.38 | 10.98 |
November | 22.35 | 4.73 |
December | 21.74 | -3.7 |
Annual Sum or Average | 23.13 | 9.99 |
Minimum of Months | 21.74 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F2 NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.73 | 3.82 |
April | 22.44 | 9.95 |
May | 23.64 | 15.31 |
June | 24.26 | 21.11 |
July | 24.40 | 24.13 |
August | 24.35 | 21.78 |
September | 24.04 | 18.14 |
October | 22.26 | 10.98 |
November | 21.90 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.85 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.40 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F2 N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.74 | 3.82 |
April | 22.39 | 9.95 |
May | 23.54 | 15.31 |
June | 24.23 | 21.11 |
July | 24.37 | 24.13 |
August | 24.33 | 21.78 |
September | 24.01 | 18.14 |
October | 22.30 | 10.98 |
November | 21.99 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.84 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F2 N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.74 | 3.82 |
April | 22.38 | 9.95 |
May | 23.53 | 15.31 |
June | 24.23 | 21.11 |
July | 24.38 | 24.13 |
August | 24.33 | 21.78 |
September | 24.01 | 18.14 |
October | 22.30 | 10.98 |
November | 21.98 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.84 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F2 S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.79 | -4.6 |
February | 21.84 | -2.5 |
March | 22.18 | 3.82 |
April | 22.75 | 9.95 |
May | 23.86 | 15.31 |
June | 24.27 | 21.11 |
July | 24.37 | 24.13 |
August | 24.35 | 21.78 |
September | 24.25 | 18.14 |
October | 23.44 | 10.98 |
November | 22.40 | 4.73 |
December | 21.76 | -3.7 |
Annual Sum or Average | 23.11 | 9.99 |
Minimum of Months | 21.76 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F2 S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.79 | -4.6 |
February | 21.84 | -2.5 |
March | 22.20 | 3.82 |
April | 22.77 | 9.95 |
May | 23.88 | 15.31 |
June | 24.27 | 21.11 |
July | 24.37 | 24.13 |
August | 24.35 | 21.78 |
September | 24.26 | 18.14 |
October | 23.47 | 10.98 |
November | 22.42 | 4.73 |
December | 21.77 | -3.7 |
Annual Sum or Average | 23.12 | 9.99 |
Minimum of Months | 21.77 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F2 CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.74 | -4.6 |
February | 21.05 | -2.5 |
March | 21.94 | 3.82 |
April | 23.16 | 9.95 |
May | 24.91 | 15.31 |
June | 26.06 | 21.11 |
July | 26.47 | 24.13 |
August | 26.20 | 21.78 |
September | 25.66 | 18.14 |
October | 23.56 | 10.98 |
November | 22.05 | 4.73 |
December | 20.83 | -3.7 |
Annual Sum or Average | 23.56 | 9.99 |
Minimum of Months | 20.74 | -4.6 |
Maximum of Months | 26.47 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F3 SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.75 | -4.6 |
February | 21.80 | -2.5 |
March | 22.11 | 3.82 |
April | 22.80 | 9.95 |
May | 24.03 | 15.31 |
June | 24.28 | 21.11 |
July | 24.38 | 24.13 |
August | 24.36 | 21.78 |
September | 24.24 | 18.14 |
October | 23.26 | 10.98 |
November | 22.32 | 4.73 |
December | 21.73 | -3.7 |
Annual Sum or Average | 23.10 | 9.99 |
Minimum of Months | 21.73 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F3 NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.77 | 3.82 |
April | 22.53 | 9.95 |
May | 23.85 | 15.31 |
June | 24.27 | 21.11 |
July | 24.37 | 24.13 |
August | 24.35 | 21.78 |
September | 24.08 | 18.14 |
October | 22.40 | 10.98 |
November | 22.01 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.90 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F3 SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.74 | -4.6 |
February | 21.78 | -2.5 |
March | 22.13 | 3.82 |
April | 22.79 | 9.95 |
May | 24.04 | 15.31 |
June | 24.29 | 21.11 |
July | 24.38 | 24.13 |
August | 24.37 | 21.78 |
September | 24.25 | 18.14 |
October | 23.30 | 10.98 |
November | 22.30 | 4.73 |
December | 21.73 | -3.7 |
Annual Sum or Average | 23.10 | 9.99 |
Minimum of Months | 21.73 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F3 NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.74 | 3.82 |
April | 22.47 | 9.95 |
May | 23.78 | 15.31 |
June | 24.26 | 21.11 |
July | 24.40 | 24.13 |
August | 24.35 | 21.78 |
September | 24.05 | 18.14 |
October | 22.30 | 10.98 |
November | 21.93 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.87 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.40 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F3 N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.75 | 3.82 |
April | 22.44 | 9.95 |
May | 23.74 | 15.31 |
June | 24.23 | 21.11 |
July | 24.38 | 24.13 |
August | 24.33 | 21.78 |
September | 24.03 | 18.14 |
October | 22.39 | 10.98 |
November | 22.05 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.88 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F3 N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.75 | 3.82 |
April | 22.44 | 9.95 |
May | 23.74 | 15.31 |
June | 24.23 | 21.11 |
July | 24.38 | 24.13 |
August | 24.33 | 21.78 |
September | 24.02 | 18.14 |
October | 22.38 | 10.98 |
November | 22.04 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.87 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F3 S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.80 | -4.6 |
February | 21.85 | -2.5 |
March | 22.24 | 3.82 |
April | 22.83 | 9.95 |
May | 24.03 | 15.31 |
June | 24.27 | 21.11 |
July | 24.37 | 24.13 |
August | 24.35 | 21.78 |
September | 24.26 | 18.14 |
October | 23.58 | 10.98 |
November | 22.49 | 4.73 |
December | 21.77 | -3.7 |
Annual Sum or Average | 23.16 | 9.99 |
Minimum of Months | 21.77 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F3 S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.80 | -4.6 |
February | 21.85 | -2.5 |
March | 22.25 | 3.82 |
April | 22.83 | 9.95 |
May | 24.03 | 15.31 |
June | 24.27 | 21.11 |
July | 24.37 | 24.13 |
August | 24.35 | 21.78 |
September | 24.26 | 18.14 |
October | 23.59 | 10.98 |
November | 22.49 | 4.73 |
December | 21.77 | -3.7 |
Annual Sum or Average | 23.16 | 9.99 |
Minimum of Months | 21.77 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F3 CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.28 | -4.6 |
February | 21.56 | -2.5 |
March | 22.38 | 3.82 |
April | 23.57 | 9.95 |
May | 25.39 | 15.31 |
June | 26.22 | 21.11 |
July | 26.57 | 24.13 |
August | 26.33 | 21.78 |
September | 25.84 | 18.14 |
October | 23.94 | 10.98 |
November | 22.49 | 4.73 |
December | 21.36 | -3.7 |
Annual Sum or Average | 23.92 | 9.99 |
Minimum of Months | 21.28 | -4.6 |
Maximum of Months | 26.57 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F4 SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.75 | -4.6 |
February | 21.79 | -2.5 |
March | 22.09 | 3.82 |
April | 22.79 | 9.95 |
May | 24.05 | 15.31 |
June | 24.28 | 21.11 |
July | 24.38 | 24.13 |
August | 24.36 | 21.78 |
September | 24.24 | 18.14 |
October | 23.26 | 10.98 |
November | 22.33 | 4.73 |
December | 21.73 | -3.7 |
Annual Sum or Average | 23.09 | 9.99 |
Minimum of Months | 21.73 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F4 NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.76 | 3.82 |
April | 22.53 | 9.95 |
May | 23.89 | 15.31 |
June | 24.26 | 21.11 |
July | 24.37 | 24.13 |
August | 24.35 | 21.78 |
September | 24.07 | 18.14 |
October | 22.41 | 10.98 |
November | 22.01 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.90 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F4 SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.74 | -4.6 |
February | 21.77 | -2.5 |
March | 22.08 | 3.82 |
April | 22.76 | 9.95 |
May | 24.05 | 15.31 |
June | 24.28 | 21.11 |
July | 24.38 | 24.13 |
August | 24.37 | 21.78 |
September | 24.25 | 18.14 |
October | 23.26 | 10.98 |
November | 22.29 | 4.73 |
December | 21.72 | -3.7 |
Annual Sum or Average | 23.09 | 9.99 |
Minimum of Months | 21.72 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F4 NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.74 | 3.82 |
April | 22.46 | 9.95 |
May | 23.82 | 15.31 |
June | 24.25 | 21.11 |
July | 24.40 | 24.13 |
August | 24.35 | 21.78 |
September | 24.04 | 18.14 |
October | 22.32 | 10.98 |
November | 21.93 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.87 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.40 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F4 N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.76 | 3.82 |
April | 22.46 | 9.95 |
May | 23.83 | 15.31 |
June | 24.23 | 21.11 |
July | 24.38 | 24.13 |
August | 24.33 | 21.78 |
September | 24.03 | 18.14 |
October | 22.44 | 10.98 |
November | 22.07 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.89 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F4 N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.75 | 3.82 |
April | 22.45 | 9.95 |
May | 23.82 | 15.31 |
June | 24.23 | 21.11 |
July | 24.38 | 24.13 |
August | 24.33 | 21.78 |
September | 24.03 | 18.14 |
October | 22.43 | 10.98 |
November | 22.06 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.89 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F4 S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.79 | -4.6 |
February | 21.84 | -2.5 |
March | 22.24 | 3.82 |
April | 22.83 | 9.95 |
May | 24.08 | 15.31 |
June | 24.27 | 21.11 |
July | 24.37 | 24.13 |
August | 24.35 | 21.78 |
September | 24.26 | 18.14 |
October | 23.62 | 10.98 |
November | 22.52 | 4.73 |
December | 21.77 | -3.7 |
Annual Sum or Average | 23.17 | 9.99 |
Minimum of Months | 21.77 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F4 S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.79 | -4.6 |
February | 21.84 | -2.5 |
March | 22.24 | 3.82 |
April | 22.83 | 9.95 |
May | 24.09 | 15.31 |
June | 24.27 | 21.11 |
July | 24.37 | 24.13 |
August | 24.35 | 21.78 |
September | 24.26 | 18.14 |
October | 23.62 | 10.98 |
November | 22.52 | 4.73 |
December | 21.77 | -3.7 |
Annual Sum or Average | 23.17 | 9.99 |
Minimum of Months | 21.77 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F4 CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.40 | -4.6 |
February | 21.69 | -2.5 |
March | 22.49 | 3.82 |
April | 23.69 | 9.95 |
May | 25.56 | 15.31 |
June | 26.31 | 21.11 |
July | 26.65 | 24.13 |
August | 26.41 | 21.78 |
September | 25.93 | 18.14 |
October | 24.07 | 10.98 |
November | 22.61 | 4.73 |
December | 21.49 | -3.7 |
Annual Sum or Average | 24.04 | 9.99 |
Minimum of Months | 21.40 | -4.6 |
Maximum of Months | 26.65 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.74 | -4.6 |
February | 21.78 | -2.5 |
March | 22.06 | 3.82 |
April | 22.77 | 9.95 |
May | 24.04 | 15.31 |
June | 24.27 | 21.11 |
July | 24.38 | 24.13 |
August | 24.36 | 21.78 |
September | 24.23 | 18.14 |
October | 23.22 | 10.98 |
November | 22.31 | 4.73 |
December | 21.73 | -3.7 |
Annual Sum or Average | 23.08 | 9.99 |
Minimum of Months | 21.73 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.76 | 3.82 |
April | 22.52 | 9.95 |
May | 23.88 | 15.31 |
June | 24.25 | 21.11 |
July | 24.37 | 24.13 |
August | 24.34 | 21.78 |
September | 24.05 | 18.14 |
October | 22.39 | 10.98 |
November | 22.00 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.89 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.73 | -4.6 |
February | 21.77 | -2.5 |
March | 22.05 | 3.82 |
April | 22.73 | 9.95 |
May | 24.03 | 15.31 |
June | 24.27 | 21.11 |
July | 24.38 | 24.13 |
August | 24.36 | 21.78 |
September | 24.24 | 18.14 |
October | 23.21 | 10.98 |
November | 22.27 | 4.73 |
December | 21.72 | -3.7 |
Annual Sum or Average | 23.07 | 9.99 |
Minimum of Months | 21.72 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.74 | 3.82 |
April | 22.46 | 9.95 |
May | 23.81 | 15.31 |
June | 24.24 | 21.11 |
July | 24.40 | 24.13 |
August | 24.35 | 21.78 |
September | 24.02 | 18.14 |
October | 22.30 | 10.98 |
November | 21.92 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.87 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.40 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.76 | 3.82 |
April | 22.46 | 9.95 |
May | 23.83 | 15.31 |
June | 24.22 | 21.11 |
July | 24.38 | 24.13 |
August | 24.33 | 21.78 |
September | 24.02 | 18.14 |
October | 22.43 | 10.98 |
November | 22.06 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.89 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.75 | 3.82 |
April | 22.45 | 9.95 |
May | 23.83 | 15.31 |
June | 24.22 | 21.11 |
July | 24.38 | 24.13 |
August | 24.33 | 21.78 |
September | 24.02 | 18.14 |
October | 22.43 | 10.98 |
November | 22.06 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.89 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.79 | -4.6 |
February | 21.84 | -2.5 |
March | 22.22 | 3.82 |
April | 22.82 | 9.95 |
May | 24.09 | 15.31 |
June | 24.26 | 21.11 |
July | 24.37 | 24.13 |
August | 24.35 | 21.78 |
September | 24.26 | 18.14 |
October | 23.59 | 10.98 |
November | 22.51 | 4.73 |
December | 21.76 | -3.7 |
Annual Sum or Average | 23.16 | 9.99 |
Minimum of Months | 21.76 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.79 | -4.6 |
February | 21.84 | -2.5 |
March | 22.22 | 3.82 |
April | 22.82 | 9.95 |
May | 24.09 | 15.31 |
June | 24.26 | 21.11 |
July | 24.37 | 24.13 |
August | 24.35 | 21.78 |
September | 24.26 | 18.14 |
October | 23.60 | 10.98 |
November | 22.51 | 4.73 |
December | 21.76 | -3.7 |
Annual Sum or Average | 23.16 | 9.99 |
Minimum of Months | 21.76 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.94 | -4.6 |
February | 22.23 | -2.5 |
March | 23.03 | 3.82 |
April | 24.24 | 9.95 |
May | 26.11 | 15.31 |
June | 26.83 | 21.11 |
July | 27.19 | 24.13 |
August | 26.95 | 21.78 |
September | 26.46 | 18.14 |
October | 24.59 | 10.98 |
November | 23.16 | 4.73 |
December | 22.05 | -3.7 |
Annual Sum or Average | 24.58 | 9.99 |
Minimum of Months | 21.94 | -4.6 |
Maximum of Months | 27.19 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F6 SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.74 | -4.6 |
February | 21.77 | -2.5 |
March | 22.00 | 3.82 |
April | 22.71 | 9.95 |
May | 23.97 | 15.31 |
June | 24.25 | 21.11 |
July | 24.37 | 24.13 |
August | 24.35 | 21.78 |
September | 24.19 | 18.14 |
October | 23.09 | 10.98 |
November | 22.24 | 4.73 |
December | 21.72 | -3.7 |
Annual Sum or Average | 23.04 | 9.99 |
Minimum of Months | 21.72 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F6 NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.75 | 3.82 |
April | 22.47 | 9.95 |
May | 23.78 | 15.31 |
June | 24.22 | 21.11 |
July | 24.37 | 24.13 |
August | 24.33 | 21.78 |
September | 23.99 | 18.14 |
October | 22.30 | 10.98 |
November | 21.94 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.86 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F6 SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.73 | -4.6 |
February | 21.75 | -2.5 |
March | 22.00 | 3.82 |
April | 22.68 | 9.95 |
May | 23.96 | 15.31 |
June | 24.25 | 21.11 |
July | 24.38 | 24.13 |
August | 24.36 | 21.78 |
September | 24.20 | 18.14 |
October | 23.08 | 10.98 |
November | 22.20 | 4.73 |
December | 21.72 | -3.7 |
Annual Sum or Average | 23.03 | 9.99 |
Minimum of Months | 21.72 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F6 NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.73 | 3.82 |
April | 22.42 | 9.95 |
May | 23.71 | 15.31 |
June | 24.20 | 21.11 |
July | 24.40 | 24.13 |
August | 24.34 | 21.78 |
September | 23.95 | 18.14 |
October | 22.21 | 10.98 |
November | 21.87 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.83 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.40 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F6 N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.74 | 3.82 |
April | 22.41 | 9.95 |
May | 23.74 | 15.31 |
June | 24.19 | 21.11 |
July | 24.38 | 24.13 |
August | 24.31 | 21.78 |
September | 23.96 | 18.14 |
October | 22.34 | 10.98 |
November | 22.01 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.85 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F6 N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.74 | 3.82 |
April | 22.41 | 9.95 |
May | 23.73 | 15.31 |
June | 24.19 | 21.11 |
July | 24.38 | 24.13 |
August | 24.31 | 21.78 |
September | 23.95 | 18.14 |
October | 22.33 | 10.98 |
November | 22.00 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.85 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F6 S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.77 | -4.6 |
February | 21.82 | -2.5 |
March | 22.15 | 3.82 |
April | 22.76 | 9.95 |
May | 24.02 | 15.31 |
June | 24.24 | 21.11 |
July | 24.37 | 24.13 |
August | 24.34 | 21.78 |
September | 24.22 | 18.14 |
October | 23.47 | 10.98 |
November | 22.45 | 4.73 |
December | 21.75 | -3.7 |
Annual Sum or Average | 23.12 | 9.99 |
Minimum of Months | 21.75 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F6 S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.77 | -4.6 |
February | 21.82 | -2.5 |
March | 22.15 | 3.82 |
April | 22.75 | 9.95 |
May | 24.02 | 15.31 |
June | 24.24 | 21.11 |
July | 24.37 | 24.13 |
August | 24.34 | 21.78 |
September | 24.23 | 18.14 |
October | 23.47 | 10.98 |
November | 22.44 | 4.73 |
December | 21.75 | -3.7 |
Annual Sum or Average | 23.12 | 9.99 |
Minimum of Months | 21.75 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F6 CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.32 | -4.6 |
February | 21.60 | -2.5 |
March | 22.38 | 3.82 |
April | 23.60 | 9.95 |
May | 25.48 | 15.31 |
June | 26.26 | 21.11 |
July | 26.64 | 24.13 |
August | 26.39 | 21.78 |
September | 25.86 | 18.14 |
October | 23.93 | 10.98 |
November | 22.50 | 4.73 |
December | 21.42 | -3.7 |
Annual Sum or Average | 23.96 | 9.99 |
Minimum of Months | 21.32 | -4.6 |
Maximum of Months | 26.64 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F7 SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.73 | -4.6 |
February | 21.76 | -2.5 |
March | 21.97 | 3.82 |
April | 22.68 | 9.95 |
May | 23.90 | 15.31 |
June | 24.23 | 21.11 |
July | 24.37 | 24.13 |
August | 24.34 | 21.78 |
September | 24.16 | 18.14 |
October | 23.00 | 10.98 |
November | 22.19 | 4.73 |
December | 21.72 | -3.7 |
Annual Sum or Average | 23.01 | 9.99 |
Minimum of Months | 21.72 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F7 NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.74 | 3.82 |
April | 22.44 | 9.95 |
May | 23.71 | 15.31 |
June | 24.20 | 21.11 |
July | 24.36 | 24.13 |
August | 24.32 | 21.78 |
September | 23.94 | 18.14 |
October | 22.24 | 10.98 |
November | 21.90 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.84 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.36 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F7 SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.72 | -4.6 |
February | 21.75 | -2.5 |
March | 21.96 | 3.82 |
April | 22.64 | 9.95 |
May | 23.89 | 15.31 |
June | 24.23 | 21.11 |
July | 24.37 | 24.13 |
August | 24.35 | 21.78 |
September | 24.17 | 18.14 |
October | 22.98 | 10.98 |
November | 22.15 | 4.73 |
December | 21.72 | -3.7 |
Annual Sum or Average | 23.00 | 9.99 |
Minimum of Months | 21.72 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F7 NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.72 | 3.82 |
April | 22.39 | 9.95 |
May | 23.63 | 15.31 |
June | 24.18 | 21.11 |
July | 24.40 | 24.13 |
August | 24.33 | 21.78 |
September | 23.90 | 18.14 |
October | 22.15 | 10.98 |
November | 21.84 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.81 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.40 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F7 N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.73 | 3.82 |
April | 22.38 | 9.95 |
May | 23.65 | 15.31 |
June | 24.17 | 21.11 |
July | 24.37 | 24.13 |
August | 24.30 | 21.78 |
September | 23.91 | 18.14 |
October | 22.27 | 10.98 |
November | 21.97 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.83 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F7 N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.73 | 3.82 |
April | 22.38 | 9.95 |
May | 23.65 | 15.31 |
June | 24.17 | 21.11 |
July | 24.38 | 24.13 |
August | 24.30 | 21.78 |
September | 23.90 | 18.14 |
October | 22.26 | 10.98 |
November | 21.96 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.83 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F7 S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.77 | -4.6 |
February | 21.80 | -2.5 |
March | 22.10 | 3.82 |
April | 22.71 | 9.95 |
May | 23.96 | 15.31 |
June | 24.23 | 21.11 |
July | 24.36 | 24.13 |
August | 24.34 | 21.78 |
September | 24.20 | 18.14 |
October | 23.37 | 10.98 |
November | 22.39 | 4.73 |
December | 21.74 | -3.7 |
Annual Sum or Average | 23.09 | 9.99 |
Minimum of Months | 21.74 | -4.6 |
Maximum of Months | 24.36 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F7 S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.77 | -4.6 |
February | 21.80 | -2.5 |
March | 22.10 | 3.82 |
April | 22.71 | 9.95 |
May | 23.96 | 15.31 |
June | 24.23 | 21.11 |
July | 24.36 | 24.13 |
August | 24.34 | 21.78 |
September | 24.20 | 18.14 |
October | 23.37 | 10.98 |
November | 22.39 | 4.73 |
December | 21.74 | -3.7 |
Annual Sum or Average | 23.09 | 9.99 |
Minimum of Months | 21.74 | -4.6 |
Maximum of Months | 24.36 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F7 CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.17 | -4.6 |
February | 21.46 | -2.5 |
March | 22.22 | 3.82 |
April | 23.46 | 9.95 |
May | 25.32 | 15.31 |
June | 26.15 | 21.11 |
July | 26.56 | 24.13 |
August | 26.30 | 21.78 |
September | 25.73 | 18.14 |
October | 23.74 | 10.98 |
November | 22.33 | 4.73 |
December | 21.28 | -3.7 |
Annual Sum or Average | 23.82 | 9.99 |
Minimum of Months | 21.17 | -4.6 |
Maximum of Months | 26.56 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F8 SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.73 | -4.6 |
February | 21.75 | -2.5 |
March | 21.94 | 3.82 |
April | 22.65 | 9.95 |
May | 23.84 | 15.31 |
June | 24.22 | 21.11 |
July | 24.37 | 24.13 |
August | 24.34 | 21.78 |
September | 24.13 | 18.14 |
October | 22.92 | 10.98 |
November | 22.14 | 4.73 |
December | 21.72 | -3.7 |
Annual Sum or Average | 22.98 | 9.99 |
Minimum of Months | 21.72 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F8 NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.74 | 3.82 |
April | 22.42 | 9.95 |
May | 23.64 | 15.31 |
June | 24.18 | 21.11 |
July | 24.36 | 24.13 |
August | 24.32 | 21.78 |
September | 23.89 | 18.14 |
October | 22.19 | 10.98 |
November | 21.87 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.82 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.36 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F8 SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.72 | -4.6 |
February | 21.74 | -2.5 |
March | 21.93 | 3.82 |
April | 22.61 | 9.95 |
May | 23.84 | 15.31 |
June | 24.22 | 21.11 |
July | 24.37 | 24.13 |
August | 24.35 | 21.78 |
September | 24.14 | 18.14 |
October | 22.90 | 10.98 |
November | 22.10 | 4.73 |
December | 21.71 | -3.7 |
Annual Sum or Average | 22.98 | 9.99 |
Minimum of Months | 21.71 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F8 NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.72 | 3.82 |
April | 22.38 | 9.95 |
May | 23.58 | 15.31 |
June | 24.16 | 21.11 |
July | 24.38 | 24.13 |
August | 24.32 | 21.78 |
September | 23.86 | 18.14 |
October | 22.11 | 10.98 |
November | 21.82 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.79 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F8 N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.73 | 3.82 |
April | 22.36 | 9.95 |
May | 23.59 | 15.31 |
June | 24.15 | 21.11 |
July | 24.37 | 24.13 |
August | 24.29 | 21.78 |
September | 23.86 | 18.14 |
October | 22.21 | 10.98 |
November | 21.93 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.81 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F8 N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.73 | 3.82 |
April | 22.36 | 9.95 |
May | 23.58 | 15.31 |
June | 24.15 | 21.11 |
July | 24.37 | 24.13 |
August | 24.29 | 21.78 |
September | 23.86 | 18.14 |
October | 22.21 | 10.98 |
November | 21.93 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.80 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F8 S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.76 | -4.6 |
February | 21.79 | -2.5 |
March | 22.06 | 3.82 |
April | 22.68 | 9.95 |
May | 23.90 | 15.31 |
June | 24.21 | 21.11 |
July | 24.36 | 24.13 |
August | 24.33 | 21.78 |
September | 24.17 | 18.14 |
October | 23.28 | 10.98 |
November | 22.33 | 4.73 |
December | 21.74 | -3.7 |
Annual Sum or Average | 23.06 | 9.99 |
Minimum of Months | 21.74 | -4.6 |
Maximum of Months | 24.36 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F8 S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.76 | -4.6 |
February | 21.79 | -2.5 |
March | 22.06 | 3.82 |
April | 22.68 | 9.95 |
May | 23.91 | 15.31 |
June | 24.21 | 21.11 |
July | 24.36 | 24.13 |
August | 24.33 | 21.78 |
September | 24.17 | 18.14 |
October | 23.28 | 10.98 |
November | 22.33 | 4.73 |
December | 21.74 | -3.7 |
Annual Sum or Average | 23.06 | 9.99 |
Minimum of Months | 21.74 | -4.6 |
Maximum of Months | 24.36 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F8 CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.08 | -4.6 |
February | 21.37 | -2.5 |
March | 22.13 | 3.82 |
April | 23.39 | 9.95 |
May | 25.23 | 15.31 |
June | 26.12 | 21.11 |
July | 26.56 | 24.13 |
August | 26.28 | 21.78 |
September | 25.67 | 18.14 |
October | 23.63 | 10.98 |
November | 22.22 | 4.73 |
December | 21.19 | -3.7 |
Annual Sum or Average | 23.75 | 9.99 |
Minimum of Months | 21.08 | -4.6 |
Maximum of Months | 26.56 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F9 SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.72 | -4.6 |
February | 21.75 | -2.5 |
March | 21.91 | 3.82 |
April | 22.62 | 9.95 |
May | 23.78 | 15.31 |
June | 24.20 | 21.11 |
July | 24.37 | 24.13 |
August | 24.33 | 21.78 |
September | 24.08 | 18.14 |
October | 22.83 | 10.98 |
November | 22.08 | 4.73 |
December | 21.72 | -3.7 |
Annual Sum or Average | 22.96 | 9.99 |
Minimum of Months | 21.72 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F9 NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.73 | 3.82 |
April | 22.41 | 9.95 |
May | 23.59 | 15.31 |
June | 24.16 | 21.11 |
July | 24.36 | 24.13 |
August | 24.31 | 21.78 |
September | 23.84 | 18.14 |
October | 22.15 | 10.98 |
November | 21.85 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.80 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.36 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F9 SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.72 | -4.6 |
February | 21.74 | -2.5 |
March | 21.90 | 3.82 |
April | 22.59 | 9.95 |
May | 23.78 | 15.31 |
June | 24.20 | 21.11 |
July | 24.37 | 24.13 |
August | 24.34 | 21.78 |
September | 24.09 | 18.14 |
October | 22.81 | 10.98 |
November | 22.04 | 4.73 |
December | 21.71 | -3.7 |
Annual Sum or Average | 22.95 | 9.99 |
Minimum of Months | 21.71 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F9 NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.72 | 3.82 |
April | 22.37 | 9.95 |
May | 23.53 | 15.31 |
June | 24.14 | 21.11 |
July | 24.37 | 24.13 |
August | 24.31 | 21.78 |
September | 23.81 | 18.14 |
October | 22.08 | 10.98 |
November | 21.81 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.78 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F9 N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.73 | 3.82 |
April | 22.36 | 9.95 |
May | 23.53 | 15.31 |
June | 24.13 | 21.11 |
July | 24.36 | 24.13 |
August | 24.28 | 21.78 |
September | 23.81 | 18.14 |
October | 22.16 | 10.98 |
November | 21.90 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.79 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.36 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F9 N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.73 | 3.82 |
April | 22.35 | 9.95 |
May | 23.52 | 15.31 |
June | 24.13 | 21.11 |
July | 24.37 | 24.13 |
August | 24.28 | 21.78 |
September | 23.80 | 18.14 |
October | 22.16 | 10.98 |
November | 21.89 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.78 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.37 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F9 S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.75 | -4.6 |
February | 21.78 | -2.5 |
March | 22.02 | 3.82 |
April | 22.65 | 9.95 |
May | 23.84 | 15.31 |
June | 24.20 | 21.11 |
July | 24.36 | 24.13 |
August | 24.33 | 21.78 |
September | 24.13 | 18.14 |
October | 23.15 | 10.98 |
November | 22.26 | 4.73 |
December | 21.73 | -3.7 |
Annual Sum or Average | 23.02 | 9.99 |
Minimum of Months | 21.73 | -4.6 |
Maximum of Months | 24.36 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F9 S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.75 | -4.6 |
February | 21.78 | -2.5 |
March | 22.02 | 3.82 |
April | 22.65 | 9.95 |
May | 23.84 | 15.31 |
June | 24.20 | 21.11 |
July | 24.36 | 24.13 |
August | 24.33 | 21.78 |
September | 24.13 | 18.14 |
October | 23.15 | 10.98 |
November | 22.26 | 4.73 |
December | 21.73 | -3.7 |
Annual Sum or Average | 23.02 | 9.99 |
Minimum of Months | 21.73 | -4.6 |
Maximum of Months | 24.36 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: F9 CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.88 | -4.6 |
February | 21.19 | -2.5 |
March | 21.99 | 3.82 |
April | 23.31 | 9.95 |
May | 25.18 | 15.31 |
June | 26.15 | 21.11 |
July | 26.63 | 24.13 |
August | 26.33 | 21.78 |
September | 25.63 | 18.14 |
October | 23.49 | 10.98 |
November | 22.05 | 4.73 |
December | 21.00 | -3.7 |
Annual Sum or Average | 23.67 | 9.99 |
Minimum of Months | 20.88 | -4.6 |
Maximum of Months | 26.63 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.74 | -4.6 |
February | 21.77 | -2.5 |
March | 21.96 | 3.82 |
April | 22.60 | 9.95 |
May | 23.55 | 15.31 |
June | 24.07 | 21.11 |
July | 24.34 | 24.13 |
August | 24.28 | 21.78 |
September | 23.88 | 18.14 |
October | 22.67 | 10.98 |
November | 22.02 | 4.73 |
December | 21.72 | -3.7 |
Annual Sum or Average | 22.89 | 9.99 |
Minimum of Months | 21.72 | -4.6 |
Maximum of Months | 24.34 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.71 | -2.5 |
March | 21.76 | 3.82 |
April | 22.44 | 9.95 |
May | 23.41 | 15.31 |
June | 24.02 | 21.11 |
July | 24.33 | 24.13 |
August | 24.25 | 21.78 |
September | 23.64 | 18.14 |
October | 22.15 | 10.98 |
November | 21.84 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.75 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.33 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.73 | -4.6 |
February | 21.76 | -2.5 |
March | 21.95 | 3.82 |
April | 22.58 | 9.95 |
May | 23.55 | 15.31 |
June | 24.07 | 21.11 |
July | 24.34 | 24.13 |
August | 24.29 | 21.78 |
September | 23.88 | 18.14 |
October | 22.65 | 10.98 |
November | 21.98 | 4.73 |
December | 21.72 | -3.7 |
Annual Sum or Average | 22.88 | 9.99 |
Minimum of Months | 21.72 | -4.6 |
Maximum of Months | 24.34 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.73 | 3.82 |
April | 22.40 | 9.95 |
May | 23.37 | 15.31 |
June | 24.00 | 21.11 |
July | 24.34 | 24.13 |
August | 24.24 | 21.78 |
September | 23.61 | 18.14 |
October | 22.08 | 10.98 |
November | 21.80 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.73 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.34 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.74 | 3.82 |
April | 22.39 | 9.95 |
May | 23.37 | 15.31 |
June | 24.01 | 21.11 |
July | 24.33 | 24.13 |
August | 24.22 | 21.78 |
September | 23.61 | 18.14 |
October | 22.13 | 10.98 |
November | 21.86 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.74 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.33 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.74 | 3.82 |
April | 22.38 | 9.95 |
May | 23.37 | 15.31 |
June | 24.01 | 21.11 |
July | 24.33 | 24.13 |
August | 24.23 | 21.78 |
September | 23.61 | 18.14 |
October | 22.13 | 10.98 |
November | 21.86 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.74 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.33 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.77 | -4.6 |
February | 21.80 | -2.5 |
March | 22.03 | 3.82 |
April | 22.62 | 9.95 |
May | 23.62 | 15.31 |
June | 24.09 | 21.11 |
July | 24.34 | 24.13 |
August | 24.28 | 21.78 |
September | 23.95 | 18.14 |
October | 22.90 | 10.98 |
November | 22.17 | 4.73 |
December | 21.74 | -3.7 |
Annual Sum or Average | 22.95 | 9.99 |
Minimum of Months | 21.74 | -4.6 |
Maximum of Months | 24.34 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.77 | -4.6 |
February | 21.80 | -2.5 |
March | 22.03 | 3.82 |
April | 22.62 | 9.95 |
May | 23.62 | 15.31 |
June | 24.09 | 21.11 |
July | 24.34 | 24.13 |
August | 24.28 | 21.78 |
September | 23.96 | 18.14 |
October | 22.90 | 10.98 |
November | 22.17 | 4.73 |
December | 21.74 | -3.7 |
Annual Sum or Average | 22.95 | 9.99 |
Minimum of Months | 21.74 | -4.6 |
Maximum of Months | 24.34 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.60 | -4.6 |
February | 21.02 | -2.5 |
March | 22.08 | 3.82 |
April | 23.66 | 9.95 |
May | 25.66 | 15.31 |
June | 26.84 | 21.11 |
July | 27.46 | 24.13 |
August | 27.02 | 21.78 |
September | 26.09 | 18.14 |
October | 23.69 | 10.98 |
November | 22.05 | 4.73 |
December | 20.73 | -3.7 |
Annual Sum or Average | 23.92 | 9.99 |
Minimum of Months | 20.60 | -4.6 |
Maximum of Months | 27.46 | 24.13 |
Report: COMPONENTS OF PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2015-09-09 19:00:30
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W] | |
January | 0.296812E+12 | 225073.237 | 26-JAN-22:00 | 9277.707 | 37445.768 | 20693.728 | 143682.794 | 0.000 | 10364.000 | 2423.229 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
February | 0.252099E+12 | 151955.609 | 04-FEB-17:15 | 11327.174 | 57042.023 | 20693.728 | 48117.813 | 0.000 | 10364.000 | 2423.229 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
March | 0.245737E+12 | 155859.818 | 04-MAR-18:00 | 13120.457 | 57042.023 | 20693.728 | 50228.373 | 0.000 | 10364.000 | 2423.229 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
April | 0.229809E+12 | 166958.717 | 16-APR-19:45 | 14401.373 | 49889.926 | 20693.728 | 0.000 | 65098.802 | 10364.000 | 2423.229 | 2446.356 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
May | 0.226424E+12 | 173376.657 | 30-MAY-17:00 | 13120.457 | 57042.023 | 20693.728 | 0.000 | 75311.151 | 0.000 | 2423.229 | 2798.061 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
June | 0.266917E+12 | 175450.518 | 19-JUN-19:00 | 14401.373 | 49889.926 | 20693.728 | 0.000 | 72928.543 | 10364.000 | 2423.229 | 3108.416 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
July | 0.327593E+12 | 187362.451 | 19-JUL-17:15 | 13120.457 | 57042.023 | 20693.728 | 0.000 | 88487.926 | 0.000 | 2423.229 | 3607.278 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.293998E+12 | 182511.003 | 04-AUG-16:15 | 11327.174 | 57142.088 | 20693.728 | 0.000 | 85322.310 | 0.000 | 2423.229 | 3607.278 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.240221E+12 | 164320.147 | 05-SEP-17:15 | 13120.457 | 57042.023 | 20693.728 | 0.000 | 66577.938 | 0.000 | 2423.229 | 2474.961 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
October | 0.214261E+12 | 124385.783 | 25-OCT-16:00 | 11327.174 | 57142.088 | 20693.728 | 20440.406 | 0.000 | 10364.000 | 2423.229 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
November | 0.241396E+12 | 158083.434 | 25-NOV-18:00 | 13120.457 | 57042.023 | 20693.728 | 52451.989 | 0.000 | 10364.000 | 2423.229 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
December | 0.285962E+12 | 180442.279 | 20-DEC-20:00 | 14401.373 | 49889.926 | 20693.728 | 81028.719 | 0.000 | 10364.000 | 2423.229 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.312123E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||||
Minimum of Months | 0.214261E+12 | 124385.783 | 9277.707 | 37445.768 | 20693.728 | 0.000 | 0.000 | 0.000 | 2423.229 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.327593E+12 | 225073.237 | 14401.373 | 57142.088 | 20693.728 | 143682.794 | 88487.926 | 10364.000 | 2423.229 | 3607.278 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: COMPONENTS OF PEAK GAS DEMAND
For: Meter
Timestamp: 2015-09-09 19:00:30
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC [Invalid/Undefined] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT {AT MAX/MIN} [W] | WATERSYSTEMS:GAS {AT MAX/MIN} [W] | WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.474634E+12 | 442243.967 | 27-JAN-07:30 | 0.000 | 0.000 | 0.000 | 442243.967 | 83123.275 | 83123.275 | 359120.692 |
February | 0.371415E+12 | 337018.720 | 01-FEB-07:00 | 0.000 | 0.000 | 0.000 | 337018.720 | 83480.235 | 83480.235 | 253538.485 |
March | 0.271306E+12 | 304780.956 | 05-MAR-06:15 | 0.000 | 0.000 | 0.000 | 304780.956 | 68683.898 | 68683.898 | 236097.058 |
April | 0.165845E+12 | 175597.149 | 02-APR-19:15 | 0.000 | 0.000 | 0.000 | 175597.149 | 73749.803 | 73749.803 | 101847.346 |
May | 0.999928E+11 | 79537.295 | 02-MAY-06:00 | 0.000 | 0.000 | 0.000 | 79537.295 | 79537.295 | 79537.295 | 0.000 |
June | 0.901787E+11 | 77047.235 | 01-JUN-06:00 | 0.000 | 0.000 | 0.000 | 77047.235 | 77047.235 | 77047.235 | 0.000 |
July | 0.882530E+11 | 74995.048 | 01-JUL-06:45 | 0.000 | 0.000 | 0.000 | 74995.048 | 74995.048 | 74995.048 | 0.000 |
August | 0.864915E+11 | 73897.211 | 29-AUG-06:00 | 0.000 | 0.000 | 0.000 | 73897.211 | 73897.211 | 73897.211 | 0.000 |
September | 0.855754E+11 | 75044.900 | 30-SEP-06:45 | 0.000 | 0.000 | 0.000 | 75044.900 | 75044.900 | 75044.900 | 0.000 |
October | 0.110837E+12 | 154365.544 | 16-OCT-06:15 | 0.000 | 0.000 | 0.000 | 154365.544 | 75145.261 | 75145.261 | 79220.283 |
November | 0.261846E+12 | 342604.795 | 25-NOV-22:15 | 0.000 | 0.000 | 0.000 | 342604.795 | 66166.696 | 66166.696 | 276438.099 |
December | 0.426906E+12 | 376294.957 | 20-DEC-20:45 | 0.000 | 0.000 | 0.000 | 376294.957 | 72288.392 | 72288.392 | 304006.565 |
Annual Sum or Average | 0.253328E+13 | 0.000 | 0.000 | 0.000 | ||||||
Minimum of Months | 0.855754E+11 | 73897.211 | 0.000 | 0.000 | 0.000 | 73897.211 | 66166.696 | 66166.696 | 0.000 | |
Maximum of Months | 0.474634E+12 | 442243.967 | 0.000 | 0.000 | 0.000 | 442243.967 | 83480.235 | 83480.235 | 359120.692 |