Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:59
Tabular Output Report in Format: HTML
Building: High-Rise Apartment
Environment: Boise Air Terminal Uo ID USA TMY3 WMO#=726810
Simulation Timestamp: 2015-09-09 19:00:31
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:31
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 4679.50 | 597.14 | 662.83 |
Net Site Energy | 4679.50 | 597.14 | 662.83 |
Total Source Energy | 11258.96 | 1436.74 | 1594.78 |
Net Source Energy | 11258.96 | 1436.74 | 1594.78 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 7836.48 |
Net Conditioned Building Area | 7059.89 |
Unconditioned Building Area | 776.58 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 159.58 | 544.55 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 353.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 296.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 162.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1137.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 750.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 61.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 12.51 | 0.00 | 0.00 | 0.00 | 0.00 | 1290.70 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 1165.01 | 0.00 | 0.00 | 0.00 | 4778.51 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 2969.94 | 1709.56 | 0.00 | 0.00 | 0.00 | 6069.22 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Boiler | 0.00 | 544.55 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Other | 159.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 353.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 242.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 54.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 162.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 1137.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 750.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 61.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 12.51 | 0.00 | 0.00 | 0.00 | 0.00 | 1290.70 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 1165.01 | 0.00 | 0.00 | 0.00 | 0.00 |
sub cat | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4778.51 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 65.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 189.42 | 242.15 | 0.00 | 0.00 | 0.00 | 0.86 |
Other | 161.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 420.68 | 242.15 | 0.00 | 0.00 | 0.00 | 0.86 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 58.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 170.65 | 218.15 | 0.00 | 0.00 | 0.00 | 0.77 |
Other | 145.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 378.99 | 218.15 | 0.00 | 0.00 | 0.00 | 0.77 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 2969.94 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 2969.94 | 100.00 |
Total On-Site and Utility Electric Sources | 2969.94 | 100.00 |
Total Electricity End Uses | 2969.94 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 6069.22 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 6069.22 | 100.00 |
Total Water End Uses | 6069.22 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 133.00 |
Time Setpoint Not Met During Occupied Cooling | 179.25 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 1144.50 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |COMPONENTS OF PEAK ELECTRICAL DEMAND
| Meter |COMPONENTS OF PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:31
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:59 |
RunPeriod | Boise Air Terminal Uo ID USA TMY3 WMO#=726810 |
Weather File | Boise Air Terminal Uo ID USA TMY3 WMO#=726810 |
Latitude [deg] | 43.62 |
Longitude [deg] | -116.2 |
Elevation [m] | 701.00 |
Time Zone | -7.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 3855.02 | 1411.96 | 515.55 | 1411.96 | 515.55 |
Window Opening Area [m2] | 1150.39 | 423.59 | 152.73 | 423.59 | 150.48 |
Window-Wall Ratio [%] | 29.84 | 30.00 | 29.62 | 30.00 | 29.19 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 3752.84 | 1411.96 | 464.46 | 1411.96 | 464.46 |
Window Opening Area [m2] | 1125.85 | 423.59 | 139.34 | 423.59 | 139.34 |
Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 29.5362 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 4.47 | 6.7128 | 0.0000 | |
F2 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F3 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F4 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
M SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 13.4255 | 0.0000 | |
F6 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F7 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F8 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F9 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
T SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 264.3872 | |
Total | 7836.48 | 23884.04 | 3855.02 | 1150.39 | 4.3335 | 39.48 | 8.6291 | |||
Conditioned Total | 7059.89 | 21517.16 | 3752.84 | 1125.85 | 3.9979 | 35.57 | 6.6700 | |||
Unconditioned Total | 776.58 | 2366.87 | 102.18 | 24.54 | 7.3840 | 26.4387 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:31
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 31-JUL-17:00 | 28-DEC-08:15 | - | - | - | 21-JUL-17:30 |
Heating | 0.00 | 187866.75 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 70644.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 13120.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 57042.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 23798.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 1965.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 2475.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 80520.40 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 171034.84 | 268387.14 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | Boiler | 0.00 | 187866.75 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 70644.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 10541.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 2579.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 57042.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 23798.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 1965.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 2475.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 80520.40 | 0.00 | 0.00 | 0.00 | 0.00 |
sub cat | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:31
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 505.38 | 590.29 | 0.00 | 0.00 | 0.00 |
Cooling | 1119.59 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 939.20 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 514.98 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 3601.91 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 2376.88 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 193.71 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 39.60 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 1262.87 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 9405.80 | 1853.16 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 71.58 | 83.61 | 0.00 | 0.00 | 0.00 |
Cooling | 158.58 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 133.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 72.94 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 510.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 336.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 27.44 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 5.61 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 178.88 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1332.29 | 262.49 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 71.58 | 83.61 | 0.00 | 0.00 | 0.00 |
Cooling | 158.58 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 133.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 72.94 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 510.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 336.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 27.44 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 5.61 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 178.88 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1332.29 | 262.49 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:31
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | -16.30 | 0.00 | -16.30 | Wetbulb [C] | 2.30 | 120.00 |
BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 36.70 | 16.70 | 17.90 | Wetbulb [C] | 4.20 | 330.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:31
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 270.00 | 180.00 | |
F2 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F2 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F2 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F2 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F2 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F2 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F3 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F3 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F3 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F3 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F3 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F3 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F4 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F4 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F4 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F4 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F4 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F4 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F6 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F6 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F6 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F6 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F6 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F6 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F7 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F7 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F7 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F7 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F7 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F7 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F8 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F8 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F8 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F8 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F8 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F8 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F9 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F9 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F9 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F9 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F9 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F9 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.30 | 0.269 | 0.283 | 77.66 | 0.00 | 0.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
GWINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | G WWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_0.48_SHGC_0.40 | 3.36 | 0.00 | 0.00 | 3.36 | 3.36 | 2.653 | 0.426 | 0.308 | No | G EWALL C | 90.00 | 90.00 | E | ||
F2WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F2 WWALL SWA | 270.00 | 90.00 | W | ||
F2WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 SWALL SWA | 180.00 | 90.00 | S | ||
F2WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 NWALL NWA | 0.00 | 90.00 | N | ||
F2WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F2 WWALL NWA | 270.00 | 90.00 | W | ||
F2WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F2 EWALL SEA | 90.00 | 90.00 | E | ||
F2WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 SWALL SEA | 180.00 | 90.00 | S | ||
F2WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 NWALL NEA | 0.00 | 90.00 | N | ||
F2WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F2 EWALL NEA | 90.00 | 90.00 | E | ||
F2WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 NWALL N1A | 0.00 | 90.00 | N | ||
F2WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 NWALL N2A | 0.00 | 90.00 | N | ||
F2WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 SWALL S1A | 180.00 | 90.00 | S | ||
F2WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 SWALL S2A | 180.00 | 90.00 | S | ||
F2WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F2 WWALL C | 270.00 | 90.00 | W | ||
F2WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F2 EWALL C | 90.00 | 90.00 | E | ||
F3WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F3 WWALL SWA | 270.00 | 90.00 | W | ||
F3WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 SWALL SWA | 180.00 | 90.00 | S | ||
F3WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 NWALL NWA | 0.00 | 90.00 | N | ||
F3WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F3 WWALL NWA | 270.00 | 90.00 | W | ||
F3WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F3 EWALL SEA | 90.00 | 90.00 | E | ||
F3WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 SWALL SEA | 180.00 | 90.00 | S | ||
F3WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 NWALL NEA | 0.00 | 90.00 | N | ||
F3WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F3 EWALL NEA | 90.00 | 90.00 | E | ||
F3WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 NWALL N1A | 0.00 | 90.00 | N | ||
F3WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 NWALL N2A | 0.00 | 90.00 | N | ||
F3WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 SWALL S1A | 180.00 | 90.00 | S | ||
F3WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 SWALL S2A | 180.00 | 90.00 | S | ||
F3WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F3 WWALL C | 270.00 | 90.00 | W | ||
F3WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F3 EWALL C | 90.00 | 90.00 | E | ||
F4WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F4 WWALL SWA | 270.00 | 90.00 | W | ||
F4WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 SWALL SWA | 180.00 | 90.00 | S | ||
F4WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 NWALL NWA | 0.00 | 90.00 | N | ||
F4WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F4 WWALL NWA | 270.00 | 90.00 | W | ||
F4WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F4 EWALL SEA | 90.00 | 90.00 | E | ||
F4WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 SWALL SEA | 180.00 | 90.00 | S | ||
F4WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 NWALL NEA | 0.00 | 90.00 | N | ||
F4WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F4 EWALL NEA | 90.00 | 90.00 | E | ||
F4WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 NWALL N1A | 0.00 | 90.00 | N | ||
F4WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 NWALL N2A | 0.00 | 90.00 | N | ||
F4WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 SWALL S1A | 180.00 | 90.00 | S | ||
F4WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 SWALL S2A | 180.00 | 90.00 | S | ||
F4WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F4 WWALL C | 270.00 | 90.00 | W | ||
F4WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F4 EWALL C | 90.00 | 90.00 | E | ||
MWINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | M WWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | M EWALL C | 90.00 | 90.00 | E | ||
F6WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F6 WWALL SWA | 270.00 | 90.00 | W | ||
F6WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 SWALL SWA | 180.00 | 90.00 | S | ||
F6WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 NWALL NWA | 0.00 | 90.00 | N | ||
F6WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F6 WWALL NWA | 270.00 | 90.00 | W | ||
F6WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F6 EWALL SEA | 90.00 | 90.00 | E | ||
F6WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 SWALL SEA | 180.00 | 90.00 | S | ||
F6WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 NWALL NEA | 0.00 | 90.00 | N | ||
F6WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F6 EWALL NEA | 90.00 | 90.00 | E | ||
F6WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 NWALL N1A | 0.00 | 90.00 | N | ||
F6WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 NWALL N2A | 0.00 | 90.00 | N | ||
F6WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 SWALL S1A | 180.00 | 90.00 | S | ||
F6WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 SWALL S2A | 180.00 | 90.00 | S | ||
F6WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F6 WWALL C | 270.00 | 90.00 | W | ||
F6WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F6 EWALL C | 90.00 | 90.00 | E | ||
F7WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F7 WWALL SWA | 270.00 | 90.00 | W | ||
F7WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 SWALL SWA | 180.00 | 90.00 | S | ||
F7WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 NWALL NWA | 0.00 | 90.00 | N | ||
F7WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F7 WWALL NWA | 270.00 | 90.00 | W | ||
F7WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F7 EWALL SEA | 90.00 | 90.00 | E | ||
F7WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 SWALL SEA | 180.00 | 90.00 | S | ||
F7WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 NWALL NEA | 0.00 | 90.00 | N | ||
F7WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F7 EWALL NEA | 90.00 | 90.00 | E | ||
F7WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 NWALL N1A | 0.00 | 90.00 | N | ||
F7WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 NWALL N2A | 0.00 | 90.00 | N | ||
F7WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 SWALL S1A | 180.00 | 90.00 | S | ||
F7WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 SWALL S2A | 180.00 | 90.00 | S | ||
F7WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F7 WWALL C | 270.00 | 90.00 | W | ||
F7WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F7 EWALL C | 90.00 | 90.00 | E | ||
F8WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F8 WWALL SWA | 270.00 | 90.00 | W | ||
F8WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 SWALL SWA | 180.00 | 90.00 | S | ||
F8WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 NWALL NWA | 0.00 | 90.00 | N | ||
F8WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F8 WWALL NWA | 270.00 | 90.00 | W | ||
F8WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F8 EWALL SEA | 90.00 | 90.00 | E | ||
F8WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 SWALL SEA | 180.00 | 90.00 | S | ||
F8WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 NWALL NEA | 0.00 | 90.00 | N | ||
F8WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F8 EWALL NEA | 90.00 | 90.00 | E | ||
F8WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 NWALL N1A | 0.00 | 90.00 | N | ||
F8WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 NWALL N2A | 0.00 | 90.00 | N | ||
F8WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 SWALL S1A | 180.00 | 90.00 | S | ||
F8WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 SWALL S2A | 180.00 | 90.00 | S | ||
F8WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F8 WWALL C | 270.00 | 90.00 | W | ||
F8WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F8 EWALL C | 90.00 | 90.00 | E | ||
F9WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F9 WWALL SWA | 270.00 | 90.00 | W | ||
F9WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 SWALL SWA | 180.00 | 90.00 | S | ||
F9WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 NWALL NWA | 0.00 | 90.00 | N | ||
F9WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F9 WWALL NWA | 270.00 | 90.00 | W | ||
F9WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F9 EWALL SEA | 90.00 | 90.00 | E | ||
F9WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 SWALL SEA | 180.00 | 90.00 | S | ||
F9WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 NWALL NEA | 0.00 | 90.00 | N | ||
F9WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F9 EWALL NEA | 90.00 | 90.00 | E | ||
F9WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 NWALL N1A | 0.00 | 90.00 | N | ||
F9WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 NWALL N2A | 0.00 | 90.00 | N | ||
F9WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 SWALL S1A | 180.00 | 90.00 | S | ||
F9WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 SWALL S2A | 180.00 | 90.00 | S | ||
F9WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F9 WWALL C | 270.00 | 90.00 | W | ||
F9WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F9 EWALL C | 90.00 | 90.00 | E | ||
TWINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | T WWALL C | 270.00 | 90.00 | W | ||
TWINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | T EWALL C | 90.00 | 90.00 | E | ||
Total or Average | 1150.39 | 2.653 | 0.426 | 0.308 | ||||||||||||
North Total or Average | 423.59 | 2.653 | 0.426 | 0.308 | ||||||||||||
Non-North Total or Average | 726.80 | 2.653 | 0.426 | 0.308 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:31
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:31
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
G SW APARTMENT_LIGHTS_HARDWIRED | G SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G NW APARTMENT_LIGHTS_HARDWIRED | G NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
OFFICE_LIGHTS_HARDWIRED | OFFICE | 14.7681 | 88.25 | 1303.26 | GeneralLights | LTG_OFF_SCH | 62.05 | 168.00 | 61.07 | 0.0000 | Y | 14.94 |
G NE APARTMENT_LIGHTS_HARDWIRED | G NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G N1 APARTMENT_LIGHTS_HARDWIRED | G N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G N2 APARTMENT_LIGHTS_HARDWIRED | G N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G S1 APARTMENT_LIGHTS_HARDWIRED | G S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G S2 APARTMENT_LIGHTS_HARDWIRED | G S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G CORRIDOR_LIGHTS_HARDWIRED | G CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F2 SW APARTMENT_LIGHTS_HARDWIRED | F2 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 NW APARTMENT_LIGHTS_HARDWIRED | F2 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 SE APARTMENT_LIGHTS_HARDWIRED | F2 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 NE APARTMENT_LIGHTS_HARDWIRED | F2 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 N1 APARTMENT_LIGHTS_HARDWIRED | F2 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 N2 APARTMENT_LIGHTS_HARDWIRED | F2 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 S1 APARTMENT_LIGHTS_HARDWIRED | F2 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 S2 APARTMENT_LIGHTS_HARDWIRED | F2 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 CORRIDOR_LIGHTS_HARDWIRED | F2 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F3 SW APARTMENT_LIGHTS_HARDWIRED | F3 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 NW APARTMENT_LIGHTS_HARDWIRED | F3 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 SE APARTMENT_LIGHTS_HARDWIRED | F3 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 NE APARTMENT_LIGHTS_HARDWIRED | F3 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 N1 APARTMENT_LIGHTS_HARDWIRED | F3 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 N2 APARTMENT_LIGHTS_HARDWIRED | F3 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 S1 APARTMENT_LIGHTS_HARDWIRED | F3 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 S2 APARTMENT_LIGHTS_HARDWIRED | F3 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 CORRIDOR_LIGHTS_HARDWIRED | F3 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F4 SW APARTMENT_LIGHTS_HARDWIRED | F4 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 NW APARTMENT_LIGHTS_HARDWIRED | F4 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 SE APARTMENT_LIGHTS_HARDWIRED | F4 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 NE APARTMENT_LIGHTS_HARDWIRED | F4 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 N1 APARTMENT_LIGHTS_HARDWIRED | F4 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 N2 APARTMENT_LIGHTS_HARDWIRED | F4 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 S1 APARTMENT_LIGHTS_HARDWIRED | F4 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 S2 APARTMENT_LIGHTS_HARDWIRED | F4 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 CORRIDOR_LIGHTS_HARDWIRED | F4 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
M SW APARTMENT_LIGHTS_HARDWIRED | M SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M NW APARTMENT_LIGHTS_HARDWIRED | M NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M SE APARTMENT_LIGHTS_HARDWIRED | M SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M NE APARTMENT_LIGHTS_HARDWIRED | M NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M N1 APARTMENT_LIGHTS_HARDWIRED | M N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M N2 APARTMENT_LIGHTS_HARDWIRED | M N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M S1 APARTMENT_LIGHTS_HARDWIRED | M S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M S2 APARTMENT_LIGHTS_HARDWIRED | M S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M CORRIDOR_LIGHTS_HARDWIRED | M CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F6 SW APARTMENT_LIGHTS_HARDWIRED | F6 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 NW APARTMENT_LIGHTS_HARDWIRED | F6 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 SE APARTMENT_LIGHTS_HARDWIRED | F6 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 NE APARTMENT_LIGHTS_HARDWIRED | F6 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 N1 APARTMENT_LIGHTS_HARDWIRED | F6 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 N2 APARTMENT_LIGHTS_HARDWIRED | F6 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 S1 APARTMENT_LIGHTS_HARDWIRED | F6 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 S2 APARTMENT_LIGHTS_HARDWIRED | F6 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 CORRIDOR_LIGHTS_HARDWIRED | F6 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F7 SW APARTMENT_LIGHTS_HARDWIRED | F7 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 NW APARTMENT_LIGHTS_HARDWIRED | F7 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 SE APARTMENT_LIGHTS_HARDWIRED | F7 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 NE APARTMENT_LIGHTS_HARDWIRED | F7 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 N1 APARTMENT_LIGHTS_HARDWIRED | F7 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 N2 APARTMENT_LIGHTS_HARDWIRED | F7 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 S1 APARTMENT_LIGHTS_HARDWIRED | F7 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 S2 APARTMENT_LIGHTS_HARDWIRED | F7 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 CORRIDOR_LIGHTS_HARDWIRED | F7 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F8 SW APARTMENT_LIGHTS_HARDWIRED | F8 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 NW APARTMENT_LIGHTS_HARDWIRED | F8 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 SE APARTMENT_LIGHTS_HARDWIRED | F8 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 NE APARTMENT_LIGHTS_HARDWIRED | F8 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 N1 APARTMENT_LIGHTS_HARDWIRED | F8 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 N2 APARTMENT_LIGHTS_HARDWIRED | F8 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 S1 APARTMENT_LIGHTS_HARDWIRED | F8 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 S2 APARTMENT_LIGHTS_HARDWIRED | F8 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 CORRIDOR_LIGHTS_HARDWIRED | F8 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F9 SW APARTMENT_LIGHTS_HARDWIRED | F9 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 NW APARTMENT_LIGHTS_HARDWIRED | F9 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 SE APARTMENT_LIGHTS_HARDWIRED | F9 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 NE APARTMENT_LIGHTS_HARDWIRED | F9 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 N1 APARTMENT_LIGHTS_HARDWIRED | F9 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 N2 APARTMENT_LIGHTS_HARDWIRED | F9 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 S1 APARTMENT_LIGHTS_HARDWIRED | F9 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 S2 APARTMENT_LIGHTS_HARDWIRED | F9 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 CORRIDOR_LIGHTS_HARDWIRED | F9 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
T SW APARTMENT_LIGHTS_HARDWIRED | T SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T NW APARTMENT_LIGHTS_HARDWIRED | T NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T SE APARTMENT_LIGHTS_HARDWIRED | T SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T NE APARTMENT_LIGHTS_HARDWIRED | T NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T N1 APARTMENT_LIGHTS_HARDWIRED | T N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T N2 APARTMENT_LIGHTS_HARDWIRED | T N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T S1 APARTMENT_LIGHTS_HARDWIRED | T S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T S2 APARTMENT_LIGHTS_HARDWIRED | T S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T CORRIDOR_LIGHTS_HARDWIRED | T CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
G SW APARTMENT_LIGHTS_PLUGIN | G SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G NW APARTMENT_LIGHTS_PLUGIN | G NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
OFFICE_LIGHTS_PLUGIN | OFFICE | 14.7681 | 88.25 | 1303.26 | GeneralLights-plugin | LTG_OFF_SCH | 62.05 | 168.00 | 61.07 | 0.0000 | Y | 14.94 |
G NE APARTMENT_LIGHTS_PLUGIN | G NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G N1 APARTMENT_LIGHTS_PLUGIN | G N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G N2 APARTMENT_LIGHTS_PLUGIN | G N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G S1 APARTMENT_LIGHTS_PLUGIN | G S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G S2 APARTMENT_LIGHTS_PLUGIN | G S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 SW APARTMENT_LIGHTS_PLUGIN | F2 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 NW APARTMENT_LIGHTS_PLUGIN | F2 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 SE APARTMENT_LIGHTS_PLUGIN | F2 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 NE APARTMENT_LIGHTS_PLUGIN | F2 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 N1 APARTMENT_LIGHTS_PLUGIN | F2 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 N2 APARTMENT_LIGHTS_PLUGIN | F2 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 S1 APARTMENT_LIGHTS_PLUGIN | F2 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 S2 APARTMENT_LIGHTS_PLUGIN | F2 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 SW APARTMENT_LIGHTS_PLUGIN | F3 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 NW APARTMENT_LIGHTS_PLUGIN | F3 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 SE APARTMENT_LIGHTS_PLUGIN | F3 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 NE APARTMENT_LIGHTS_PLUGIN | F3 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 N1 APARTMENT_LIGHTS_PLUGIN | F3 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 N2 APARTMENT_LIGHTS_PLUGIN | F3 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 S1 APARTMENT_LIGHTS_PLUGIN | F3 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 S2 APARTMENT_LIGHTS_PLUGIN | F3 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 SW APARTMENT_LIGHTS_PLUGIN | F4 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 NW APARTMENT_LIGHTS_PLUGIN | F4 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 SE APARTMENT_LIGHTS_PLUGIN | F4 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 NE APARTMENT_LIGHTS_PLUGIN | F4 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 N1 APARTMENT_LIGHTS_PLUGIN | F4 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 N2 APARTMENT_LIGHTS_PLUGIN | F4 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 S1 APARTMENT_LIGHTS_PLUGIN | F4 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 S2 APARTMENT_LIGHTS_PLUGIN | F4 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M SW APARTMENT_LIGHTS_PLUGIN | M SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M NW APARTMENT_LIGHTS_PLUGIN | M NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M SE APARTMENT_LIGHTS_PLUGIN | M SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M NE APARTMENT_LIGHTS_PLUGIN | M NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M N1 APARTMENT_LIGHTS_PLUGIN | M N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M N2 APARTMENT_LIGHTS_PLUGIN | M N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M S1 APARTMENT_LIGHTS_PLUGIN | M S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M S2 APARTMENT_LIGHTS_PLUGIN | M S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M CORRIDOR_LIGHTS_PLUGIN | M CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights-plugin | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F6 SW APARTMENT_LIGHTS_PLUGIN | F6 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 NW APARTMENT_LIGHTS_PLUGIN | F6 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 SE APARTMENT_LIGHTS_PLUGIN | F6 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 NE APARTMENT_LIGHTS_PLUGIN | F6 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 N1 APARTMENT_LIGHTS_PLUGIN | F6 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 N2 APARTMENT_LIGHTS_PLUGIN | F6 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 S1 APARTMENT_LIGHTS_PLUGIN | F6 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 S2 APARTMENT_LIGHTS_PLUGIN | F6 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 SW APARTMENT_LIGHTS_PLUGIN | F7 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 NW APARTMENT_LIGHTS_PLUGIN | F7 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 SE APARTMENT_LIGHTS_PLUGIN | F7 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 NE APARTMENT_LIGHTS_PLUGIN | F7 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 N1 APARTMENT_LIGHTS_PLUGIN | F7 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 N2 APARTMENT_LIGHTS_PLUGIN | F7 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 S1 APARTMENT_LIGHTS_PLUGIN | F7 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 S2 APARTMENT_LIGHTS_PLUGIN | F7 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 SW APARTMENT_LIGHTS_PLUGIN | F8 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 NW APARTMENT_LIGHTS_PLUGIN | F8 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 SE APARTMENT_LIGHTS_PLUGIN | F8 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 NE APARTMENT_LIGHTS_PLUGIN | F8 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 N1 APARTMENT_LIGHTS_PLUGIN | F8 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 N2 APARTMENT_LIGHTS_PLUGIN | F8 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 S1 APARTMENT_LIGHTS_PLUGIN | F8 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 S2 APARTMENT_LIGHTS_PLUGIN | F8 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 SW APARTMENT_LIGHTS_PLUGIN | F9 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 NW APARTMENT_LIGHTS_PLUGIN | F9 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 SE APARTMENT_LIGHTS_PLUGIN | F9 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 NE APARTMENT_LIGHTS_PLUGIN | F9 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 N1 APARTMENT_LIGHTS_PLUGIN | F9 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 N2 APARTMENT_LIGHTS_PLUGIN | F9 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 S1 APARTMENT_LIGHTS_PLUGIN | F9 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 S2 APARTMENT_LIGHTS_PLUGIN | F9 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T SW APARTMENT_LIGHTS_PLUGIN | T SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T NW APARTMENT_LIGHTS_PLUGIN | T NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T SE APARTMENT_LIGHTS_PLUGIN | T SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T NE APARTMENT_LIGHTS_PLUGIN | T NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T N1 APARTMENT_LIGHTS_PLUGIN | T N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T N2 APARTMENT_LIGHTS_PLUGIN | T N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T S1 APARTMENT_LIGHTS_PLUGIN | T S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T S2 APARTMENT_LIGHTS_PLUGIN | T S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
Interior Lighting Total | 2.2679 | 14974.03 | 33959.19 | 296.56 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 10364.00 | AstronomicalClock | - | 83.58 | 83.58 | 162.61 | |
Exterior Lighting Total | 10364.00 | 162.61 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:31
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
CENTRAL BOILER | Boiler:HotWater | 277690.72 | 0.75 | ||
CENTRAL TOWER | EvaporativeFluidCooler:SingleSpeed | 222152.57 |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
HEAT PUMP COOLING MODE AIRLOOP G SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3596.54 | 2587.54 | 1009.00 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3307.90 | 2383.07 | 924.83 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP OFFICE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5345.85 | 3810.25 | 1535.60 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2432.32 | 1758.73 | 673.59 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 1637.65 | 1184.05 | 453.59 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 1611.58 | 1165.49 | 446.09 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2368.79 | 1669.08 | 699.71 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2458.09 | 1733.38 | 724.71 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4552.52 | 3285.58 | 1266.94 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4131.93 | 2985.45 | 1146.48 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4472.48 | 3205.42 | 1267.06 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3191.48 | 2317.14 | 874.34 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2144.05 | 1552.22 | 591.83 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2123.24 | 1537.37 | 585.88 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3019.75 | 2145.15 | 874.60 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3052.86 | 2168.94 | 883.92 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4581.89 | 3312.29 | 1269.60 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4168.90 | 3021.74 | 1147.16 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4232.16 | 3040.79 | 1191.37 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3247.74 | 2365.18 | 882.56 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2189.90 | 1589.45 | 600.45 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2169.19 | 1574.65 | 594.54 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3078.57 | 2192.08 | 886.49 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3094.11 | 2203.24 | 890.86 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4603.95 | 3334.15 | 1269.80 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4191.21 | 3043.74 | 1147.47 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4241.97 | 3053.68 | 1188.30 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3285.06 | 2394.05 | 891.01 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2212.07 | 1608.64 | 603.43 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2191.45 | 1593.89 | 597.55 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3108.37 | 2216.99 | 891.38 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3121.41 | 2226.36 | 895.05 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4650.74 | 3372.60 | 1278.14 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4238.51 | 3082.52 | 1155.99 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4298.30 | 3098.90 | 1199.40 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3334.45 | 2434.15 | 900.30 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2257.05 | 1643.51 | 613.54 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2236.50 | 1628.81 | 607.69 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3159.62 | 2256.70 | 902.92 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3172.29 | 2265.80 | 906.49 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4615.94 | 3351.85 | 1264.09 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4202.20 | 3060.66 | 1141.53 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4274.97 | 3086.17 | 1188.80 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3302.10 | 2414.75 | 887.35 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2222.52 | 1621.16 | 601.36 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2202.14 | 1606.57 | 595.58 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3130.01 | 2237.82 | 892.20 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3142.63 | 2246.88 | 895.75 | 0.71 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4609.57 | 3350.95 | 1258.62 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4195.59 | 3059.57 | 1136.02 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4278.69 | 3092.38 | 1186.31 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3298.33 | 2415.42 | 882.91 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2216.20 | 1618.67 | 597.54 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2195.95 | 1604.16 | 591.80 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3127.68 | 2238.26 | 889.42 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3140.28 | 2247.31 | 892.97 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4620.51 | 3362.08 | 1258.42 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4206.46 | 3070.62 | 1135.84 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4297.40 | 3109.01 | 1188.39 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3310.28 | 2427.05 | 883.23 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2227.45 | 1628.52 | 598.93 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2207.34 | 1614.11 | 593.23 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3141.27 | 2249.94 | 891.33 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3153.89 | 2259.01 | 894.88 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4769.64 | 3472.09 | 1297.55 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4350.19 | 3176.71 | 1173.49 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4412.41 | 3194.52 | 1217.90 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3369.06 | 2472.21 | 896.86 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2353.31 | 1720.28 | 633.03 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2333.10 | 1705.79 | 627.31 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3236.76 | 2320.35 | 916.41 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3250.41 | 2330.28 | 920.13 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5933.42 | 4300.71 | 1632.71 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5349.33 | 3888.52 | 1460.81 | 0.73 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5483.46 | 3966.99 | 1516.47 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4300.51 | 3116.70 | 1183.81 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3301.70 | 2372.87 | 928.83 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3306.27 | 2374.11 | 932.16 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4452.28 | 3195.64 | 1256.65 | 0.72 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4463.37 | 3203.58 | 1259.79 | 0.72 | 0.00 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
None |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
HEAT PUMP HEATING MODE AIRLOOP G SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 3596.54 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 3307.90 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP OFFICE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5345.85 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 2432.32 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 1637.65 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 1611.58 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2368.79 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2458.09 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4552.52 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4131.93 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4472.48 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3191.48 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2144.05 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2123.24 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3019.75 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3052.86 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4581.89 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4168.90 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4232.16 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3247.74 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2189.90 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2169.19 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3078.57 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3094.11 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4603.95 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4191.21 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4241.97 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3285.06 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2212.07 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2191.45 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3108.37 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3121.41 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4650.74 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4238.51 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4298.30 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3334.45 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2257.05 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2236.50 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3159.62 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3172.29 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4615.94 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4202.20 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4274.97 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3302.10 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2222.52 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2202.14 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3130.01 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3142.63 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4609.57 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4195.59 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4278.69 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3298.33 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2216.20 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2195.95 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3127.68 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3140.28 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4620.51 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4206.46 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4297.40 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3310.28 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2227.45 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2207.34 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3141.27 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3153.89 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4769.64 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4350.19 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4412.41 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3369.06 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2353.31 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2333.10 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3236.76 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3250.41 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5933.42 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5349.33 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5483.46 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4300.51 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3301.70 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3306.27 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4452.28 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4463.37 | 0.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW | Coil:Heating:Electric | 3760.47 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW | Coil:Heating:Electric | 3775.08 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE | Coil:Heating:Electric | 4652.81 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE | Coil:Heating:Electric | 3770.34 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 | Coil:Heating:Electric | 2902.28 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 | Coil:Heating:Electric | 2902.17 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 | Coil:Heating:Electric | 2884.58 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 | Coil:Heating:Electric | 2890.75 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW | Coil:Heating:Electric | 3613.42 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW | Coil:Heating:Electric | 3620.19 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE | Coil:Heating:Electric | 3627.05 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE | Coil:Heating:Electric | 3615.49 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 | Coil:Heating:Electric | 2552.26 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 | Coil:Heating:Electric | 2552.15 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 | Coil:Heating:Electric | 2548.35 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 | Coil:Heating:Electric | 2549.39 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW | Coil:Heating:Electric | 3612.74 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW | Coil:Heating:Electric | 3619.74 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE | Coil:Heating:Electric | 3610.92 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE | Coil:Heating:Electric | 3615.99 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 | Coil:Heating:Electric | 2505.97 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 | Coil:Heating:Electric | 2505.88 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 | Coil:Heating:Electric | 2499.87 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 | Coil:Heating:Electric | 2499.96 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW | Coil:Heating:Electric | 3678.92 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW | Coil:Heating:Electric | 3685.23 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE | Coil:Heating:Electric | 3676.25 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE | Coil:Heating:Electric | 3682.36 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 | Coil:Heating:Electric | 2533.67 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 | Coil:Heating:Electric | 2533.60 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 | Coil:Heating:Electric | 2527.99 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 | Coil:Heating:Electric | 2527.95 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW | Coil:Heating:Electric | 3724.22 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW | Coil:Heating:Electric | 3728.46 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE | Coil:Heating:Electric | 3722.17 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE | Coil:Heating:Electric | 3726.39 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 | Coil:Heating:Electric | 2546.94 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 | Coil:Heating:Electric | 2546.89 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 | Coil:Heating:Electric | 2543.31 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 | Coil:Heating:Electric | 2543.26 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW | Coil:Heating:Electric | 3825.60 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW | Coil:Heating:Electric | 3829.61 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE | Coil:Heating:Electric | 3824.25 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE | Coil:Heating:Electric | 3828.26 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 | Coil:Heating:Electric | 2621.07 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 | Coil:Heating:Electric | 2621.04 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 | Coil:Heating:Electric | 2617.65 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 | Coil:Heating:Electric | 2617.62 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW | Coil:Heating:Electric | 3898.88 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW | Coil:Heating:Electric | 3901.65 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE | Coil:Heating:Electric | 3898.18 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE | Coil:Heating:Electric | 3900.95 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 | Coil:Heating:Electric | 2670.23 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 | Coil:Heating:Electric | 2670.21 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 | Coil:Heating:Electric | 2668.08 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 | Coil:Heating:Electric | 2668.06 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW | Coil:Heating:Electric | 3977.43 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW | Coil:Heating:Electric | 3978.75 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE | Coil:Heating:Electric | 3977.33 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE | Coil:Heating:Electric | 3978.65 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 | Coil:Heating:Electric | 2727.07 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 | Coil:Heating:Electric | 2727.06 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 | Coil:Heating:Electric | 2726.37 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 | Coil:Heating:Electric | 2726.37 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW | Coil:Heating:Electric | 4203.83 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW | Coil:Heating:Electric | 4200.93 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE | Coil:Heating:Electric | 4204.28 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE | Coil:Heating:Electric | 4201.39 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 | Coil:Heating:Electric | 2921.24 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 | Coil:Heating:Electric | 2921.25 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 | Coil:Heating:Electric | 2924.33 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 | Coil:Heating:Electric | 2924.34 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW | Coil:Heating:Electric | 4999.34 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW | Coil:Heating:Electric | 5003.61 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE | Coil:Heating:Electric | 5000.21 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE | Coil:Heating:Electric | 5004.47 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 | Coil:Heating:Electric | 3771.06 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 | Coil:Heating:Electric | 3771.08 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 | Coil:Heating:Electric | 3764.02 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 | Coil:Heating:Electric | 3764.04 | 1.00 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
AIRLOOP G SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 309.14 | 1160.84 | 1.00 | General |
AIRLOOP G NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 285.54 | 1160.84 | 1.00 | General |
AIRLOOP OFFICE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.39 | 447.15 | 1160.84 | 1.00 | General |
AIRLOOP G NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 207.59 | 1160.84 | 1.00 | General |
AIRLOOP G N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.12 | 139.67 | 1160.84 | 1.00 | General |
AIRLOOP G N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.12 | 137.40 | 1160.84 | 1.00 | General |
AIRLOOP G S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 190.65 | 1160.84 | 1.00 | General |
AIRLOOP G S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 198.50 | 1160.84 | 1.00 | General |
AIRLOOP F2 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.34 | 395.56 | 1160.84 | 1.00 | General |
AIRLOOP F2 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 360.16 | 1160.84 | 1.00 | General |
AIRLOOP F2 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 380.12 | 1160.84 | 1.00 | General |
AIRLOOP F2 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 276.81 | 1160.84 | 1.00 | General |
AIRLOOP F2 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 185.07 | 1160.84 | 1.00 | General |
AIRLOOP F2 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 183.26 | 1160.84 | 1.00 | General |
AIRLOOP F2 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 249.24 | 1160.84 | 1.00 | General |
AIRLOOP F2 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 252.15 | 1160.84 | 1.00 | General |
AIRLOOP F3 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.34 | 398.67 | 1160.84 | 1.00 | General |
AIRLOOP F3 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 364.43 | 1160.84 | 1.00 | General |
AIRLOOP F3 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 360.33 | 1160.84 | 1.00 | General |
AIRLOOP F3 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 283.11 | 1160.84 | 1.00 | General |
AIRLOOP F3 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 189.87 | 1160.84 | 1.00 | General |
AIRLOOP F3 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 188.06 | 1160.84 | 1.00 | General |
AIRLOOP F3 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 255.23 | 1160.84 | 1.00 | General |
AIRLOOP F3 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 256.59 | 1160.84 | 1.00 | General |
AIRLOOP F4 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.35 | 401.67 | 1160.84 | 1.00 | General |
AIRLOOP F4 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 367.45 | 1160.84 | 1.00 | General |
AIRLOOP F4 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 362.22 | 1160.84 | 1.00 | General |
AIRLOOP F4 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 286.31 | 1160.84 | 1.00 | General |
AIRLOOP F4 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 192.40 | 1160.84 | 1.00 | General |
AIRLOOP F4 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 190.59 | 1160.84 | 1.00 | General |
AIRLOOP F4 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 258.46 | 1160.84 | 1.00 | General |
AIRLOOP F4 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 259.61 | 1160.84 | 1.00 | General |
AIRLOOP M SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.35 | 406.65 | 1160.84 | 1.00 | General |
AIRLOOP M NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 372.47 | 1160.84 | 1.00 | General |
AIRLOOP M SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 368.02 | 1160.84 | 1.00 | General |
AIRLOOP M NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 291.47 | 1160.84 | 1.00 | General |
AIRLOOP M N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 196.81 | 1160.84 | 1.00 | General |
AIRLOOP M N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 195.01 | 1160.84 | 1.00 | General |
AIRLOOP M S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 263.47 | 1160.84 | 1.00 | General |
AIRLOOP M S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 264.59 | 1160.84 | 1.00 | General |
AIRLOOP F6 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.35 | 404.32 | 1160.84 | 1.00 | General |
AIRLOOP F6 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 370.00 | 1160.84 | 1.00 | General |
AIRLOOP F6 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 366.67 | 1160.84 | 1.00 | General |
AIRLOOP F6 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 289.29 | 1160.84 | 1.00 | General |
AIRLOOP F6 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 194.19 | 1160.84 | 1.00 | General |
AIRLOOP F6 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 192.40 | 1160.84 | 1.00 | General |
AIRLOOP F6 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 261.29 | 1160.84 | 1.00 | General |
AIRLOOP F6 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 262.40 | 1160.84 | 1.00 | General |
AIRLOOP F7 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.35 | 404.40 | 1160.84 | 1.00 | General |
AIRLOOP F7 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 370.05 | 1160.84 | 1.00 | General |
AIRLOOP F7 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 367.61 | 1160.84 | 1.00 | General |
AIRLOOP F7 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 289.54 | 1160.84 | 1.00 | General |
AIRLOOP F7 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 193.99 | 1160.84 | 1.00 | General |
AIRLOOP F7 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 192.21 | 1160.84 | 1.00 | General |
AIRLOOP F7 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 261.45 | 1160.84 | 1.00 | General |
AIRLOOP F7 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 262.56 | 1160.84 | 1.00 | General |
AIRLOOP F8 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.35 | 405.94 | 1160.84 | 1.00 | General |
AIRLOOP F8 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 371.58 | 1160.84 | 1.00 | General |
AIRLOOP F8 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 369.82 | 1160.84 | 1.00 | General |
AIRLOOP F8 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 291.13 | 1160.84 | 1.00 | General |
AIRLOOP F8 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 195.30 | 1160.84 | 1.00 | General |
AIRLOOP F8 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 193.53 | 1160.84 | 1.00 | General |
AIRLOOP F8 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 262.98 | 1160.84 | 1.00 | General |
AIRLOOP F8 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 264.09 | 1160.84 | 1.00 | General |
AIRLOOP F9 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.36 | 419.62 | 1160.84 | 1.00 | General |
AIRLOOP F9 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 384.78 | 1160.84 | 1.00 | General |
AIRLOOP F9 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 380.47 | 1160.84 | 1.00 | General |
AIRLOOP F9 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.26 | 296.83 | 1160.84 | 1.00 | General |
AIRLOOP F9 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 206.64 | 1160.84 | 1.00 | General |
AIRLOOP F9 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 204.86 | 1160.84 | 1.00 | General |
AIRLOOP F9 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 271.70 | 1160.84 | 1.00 | General |
AIRLOOP F9 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 272.92 | 1160.84 | 1.00 | General |
AIRLOOP T SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.45 | 518.61 | 1160.84 | 1.00 | General |
AIRLOOP T NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.41 | 470.37 | 1160.84 | 1.00 | General |
AIRLOOP T SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.41 | 475.54 | 1160.84 | 1.00 | General |
AIRLOOP T NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 371.05 | 1160.84 | 1.00 | General |
AIRLOOP T N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 278.94 | 1160.84 | 1.00 | General |
AIRLOOP T N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 278.74 | 1160.84 | 1.00 | General |
AIRLOOP T S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 379.17 | 1160.84 | 1.00 | General |
AIRLOOP T S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 380.14 | 1160.84 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
SHWSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.0003 | 36.93 | 127739.32 | 0.30 |
PLANT CIRC PUMP | Pump:ConstantSpeed | Intermittent | 224180.02 | 0.0060 | 1928.84 | 319344.75 | 0.90 |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SHWSYS1 WATER HEATER | WaterHeater:Mixed | 2.27 | 175842.64 | 0.80 | 0.00 | 0.00 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:31
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 2606.58 | 3127.90 | 0.222 | 0.266 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 32.69 | 0.00627 |
G NW APARTMENT | 2407.56 | 2889.07 | 0.205 | 0.246 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 31.44 | 0.00627 |
OFFICE | 3770.33 | 4524.39 | 0.321 | 0.385 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 36.70 | 0.00627 |
G NE APARTMENT | 1750.40 | 2100.49 | 0.149 | 0.179 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 32.86 | 0.00627 |
G N1 APARTMENT | 1177.60 | 1413.13 | 0.100 | 0.120 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.19 | 0.00627 |
G N2 APARTMENT | 1158.49 | 1390.18 | 0.099 | 0.118 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.19 | 0.00627 |
G S1 APARTMENT | 1607.53 | 1929.04 | 0.137 | 0.164 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 36.70 | 0.00627 |
G S2 APARTMENT | 1673.68 | 2008.42 | 0.142 | 0.171 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 36.70 | 0.00627 |
F2 SW APARTMENT | 3335.27 | 4002.33 | 0.284 | 0.341 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 32.69 | 0.00627 |
F2 NW APARTMENT | 3036.83 | 3644.20 | 0.259 | 0.310 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 31.44 | 0.00627 |
F2 SE APARTMENT | 3205.16 | 3846.19 | 0.273 | 0.327 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 36.70 | 0.00627 |
F2 NE APARTMENT | 2334.05 | 2800.86 | 0.199 | 0.238 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 32.86 | 0.00627 |
F2 N1 APARTMENT | 1560.49 | 1872.59 | 0.133 | 0.159 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.19 | 0.00627 |
F2 N2 APARTMENT | 1545.15 | 1854.18 | 0.132 | 0.158 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.19 | 0.00627 |
F2 S1 APARTMENT | 2101.54 | 2521.85 | 0.179 | 0.215 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 36.70 | 0.00627 |
F2 S2 APARTMENT | 2126.08 | 2551.30 | 0.181 | 0.217 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 36.70 | 0.00627 |
F3 SW APARTMENT | 3361.53 | 4033.83 | 0.286 | 0.343 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 33.11 | 0.00627 |
F3 NW APARTMENT | 3072.82 | 3687.38 | 0.262 | 0.314 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 32.07 | 0.00627 |
F3 SE APARTMENT | 3038.30 | 3645.96 | 0.259 | 0.310 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 36.70 | 0.00627 |
F3 NE APARTMENT | 2387.16 | 2864.59 | 0.203 | 0.244 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 32.86 | 0.00627 |
F3 N1 APARTMENT | 1600.93 | 1921.12 | 0.136 | 0.164 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.19 | 0.00627 |
F3 N2 APARTMENT | 1585.64 | 1902.76 | 0.135 | 0.162 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.19 | 0.00627 |
F3 S1 APARTMENT | 2152.04 | 2582.45 | 0.183 | 0.220 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 36.70 | 0.00627 |
F3 S2 APARTMENT | 2163.56 | 2596.28 | 0.184 | 0.221 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 36.70 | 0.00627 |
F4 SW APARTMENT | 3386.86 | 4064.23 | 0.288 | 0.346 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 33.11 | 0.00627 |
F4 NW APARTMENT | 3098.27 | 3717.93 | 0.264 | 0.317 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 32.07 | 0.00627 |
F4 SE APARTMENT | 3054.23 | 3665.08 | 0.260 | 0.312 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 36.70 | 0.00627 |
F4 NE APARTMENT | 2414.17 | 2897.00 | 0.206 | 0.247 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 11:15:00 | 33.28 | 0.00627 |
F4 N1 APARTMENT | 1622.25 | 1946.70 | 0.138 | 0.166 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.19 | 0.00627 |
F4 N2 APARTMENT | 1607.00 | 1928.40 | 0.137 | 0.164 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.19 | 0.00627 |
F4 S1 APARTMENT | 2179.31 | 2615.18 | 0.186 | 0.223 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 36.70 | 0.00627 |
F4 S2 APARTMENT | 2188.98 | 2626.78 | 0.186 | 0.224 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 36.70 | 0.00627 |
M SW APARTMENT | 3428.88 | 4114.65 | 0.292 | 0.350 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 33.11 | 0.00627 |
M NW APARTMENT | 3140.62 | 3768.74 | 0.267 | 0.321 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 32.07 | 0.00627 |
M SE APARTMENT | 3103.16 | 3723.79 | 0.264 | 0.317 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 36.70 | 0.00627 |
M NE APARTMENT | 2457.73 | 2949.28 | 0.209 | 0.251 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 11:15:00 | 33.28 | 0.00627 |
M N1 APARTMENT | 1659.49 | 1991.39 | 0.141 | 0.170 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.19 | 0.00627 |
M N2 APARTMENT | 1644.28 | 1973.14 | 0.140 | 0.168 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.19 | 0.00627 |
M S1 APARTMENT | 2221.59 | 2665.90 | 0.189 | 0.227 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 36.70 | 0.00627 |
M S2 APARTMENT | 2230.98 | 2677.18 | 0.190 | 0.228 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 36.70 | 0.00627 |
F6 SW APARTMENT | 3409.24 | 4091.08 | 0.290 | 0.348 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 33.11 | 0.00627 |
F6 NW APARTMENT | 3119.81 | 3743.77 | 0.266 | 0.319 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 32.07 | 0.00627 |
F6 SE APARTMENT | 3091.77 | 3710.12 | 0.263 | 0.316 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 36.70 | 0.00627 |
F6 NE APARTMENT | 2439.30 | 2927.16 | 0.208 | 0.249 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 11:15:00 | 33.28 | 0.00627 |
F6 N1 APARTMENT | 1637.40 | 1964.88 | 0.139 | 0.167 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.19 | 0.00627 |
F6 N2 APARTMENT | 1622.31 | 1946.77 | 0.138 | 0.166 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.19 | 0.00627 |
F6 S1 APARTMENT | 2203.15 | 2643.78 | 0.188 | 0.225 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 36.70 | 0.00627 |
F6 S2 APARTMENT | 2212.51 | 2655.01 | 0.188 | 0.226 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 36.70 | 0.00627 |
F7 SW APARTMENT | 3409.93 | 4091.92 | 0.290 | 0.348 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 33.11 | 0.00627 |
F7 NW APARTMENT | 3120.28 | 3744.33 | 0.266 | 0.319 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 32.07 | 0.00627 |
F7 SE APARTMENT | 3099.76 | 3719.71 | 0.264 | 0.317 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 36.70 | 0.00627 |
F7 NE APARTMENT | 2441.47 | 2929.76 | 0.208 | 0.249 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 11:15:00 | 33.28 | 0.00627 |
F7 N1 APARTMENT | 1635.71 | 1962.86 | 0.139 | 0.167 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.19 | 0.00627 |
F7 N2 APARTMENT | 1620.70 | 1944.84 | 0.138 | 0.166 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.19 | 0.00627 |
F7 S1 APARTMENT | 2204.55 | 2645.46 | 0.188 | 0.225 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 36.70 | 0.00627 |
F7 S2 APARTMENT | 2213.89 | 2656.67 | 0.188 | 0.226 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 36.70 | 0.00627 |
F8 SW APARTMENT | 3422.92 | 4107.50 | 0.291 | 0.350 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 33.11 | 0.00627 |
F8 NW APARTMENT | 3133.16 | 3759.80 | 0.267 | 0.320 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 32.07 | 0.00627 |
F8 SE APARTMENT | 3118.38 | 3742.05 | 0.265 | 0.319 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 36.70 | 0.00627 |
F8 NE APARTMENT | 2454.84 | 2945.80 | 0.209 | 0.251 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 11:15:00 | 33.28 | 0.00627 |
F8 N1 APARTMENT | 1646.70 | 1976.04 | 0.140 | 0.168 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.19 | 0.00627 |
F8 N2 APARTMENT | 1631.78 | 1958.14 | 0.139 | 0.167 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.19 | 0.00627 |
F8 S1 APARTMENT | 2217.46 | 2660.95 | 0.189 | 0.227 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 36.70 | 0.00627 |
F8 S2 APARTMENT | 2226.82 | 2672.18 | 0.190 | 0.228 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 36.70 | 0.00627 |
F9 SW APARTMENT | 3538.27 | 4245.93 | 0.301 | 0.361 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 33.11 | 0.00627 |
F9 NW APARTMENT | 3244.45 | 3893.34 | 0.276 | 0.331 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 32.07 | 0.00627 |
F9 SE APARTMENT | 3208.19 | 3849.82 | 0.273 | 0.328 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 36.70 | 0.00627 |
F9 NE APARTMENT | 2502.89 | 3003.47 | 0.213 | 0.256 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 11:15:00 | 33.28 | 0.00627 |
F9 N1 APARTMENT | 1742.35 | 2090.83 | 0.148 | 0.178 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.19 | 0.00627 |
F9 N2 APARTMENT | 1727.36 | 2072.83 | 0.147 | 0.176 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 30.19 | 0.00627 |
F9 S1 APARTMENT | 2290.96 | 2749.15 | 0.195 | 0.234 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 36.70 | 0.00627 |
F9 S2 APARTMENT | 2301.26 | 2761.51 | 0.196 | 0.235 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 36.70 | 0.00627 |
T SW APARTMENT | 4373.02 | 5247.62 | 0.372 | 0.447 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 16:15:00 | 35.36 | 0.00627 |
T NW APARTMENT | 3966.25 | 4759.50 | 0.338 | 0.405 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 33.53 | 0.00627 |
T SE APARTMENT | 4009.85 | 4811.82 | 0.341 | 0.410 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 36.70 | 0.00627 |
T NE APARTMENT | 3128.76 | 3754.52 | 0.266 | 0.320 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 36.70 | 0.00627 |
T N1 APARTMENT | 2352.04 | 2822.45 | 0.200 | 0.240 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 | 36.20 | 0.00627 |
T N2 APARTMENT | 2350.30 | 2820.35 | 0.200 | 0.240 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 15:15:00 | 36.45 | 0.00627 |
T S1 APARTMENT | 3197.14 | 3836.57 | 0.272 | 0.327 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 36.70 | 0.00627 |
T S2 APARTMENT | 3205.35 | 3846.43 | 0.273 | 0.327 | BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 36.70 | 0.00627 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 2251.93 | 2702.31 | 0.109 | 0.131 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -16.30 | 0.00098 |
G NW APARTMENT | 2264.28 | 2717.14 | 0.110 | 0.131 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -16.30 | 0.00098 |
OFFICE | 2572.00 | 3086.40 | 0.124 | 0.149 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 18:45:00 | -16.30 | 0.00098 |
G NE APARTMENT | 2260.27 | 2712.33 | 0.109 | 0.131 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -16.30 | 0.00098 |
G N1 APARTMENT | 1526.19 | 1831.43 | 0.074 | 0.089 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -16.30 | 0.00098 |
G N2 APARTMENT | 1526.10 | 1831.32 | 0.074 | 0.089 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -16.30 | 0.00098 |
G S1 APARTMENT | 1511.22 | 1813.47 | 0.073 | 0.088 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -16.30 | 0.00098 |
G S2 APARTMENT | 1516.44 | 1819.72 | 0.073 | 0.088 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -16.30 | 0.00098 |
F2 SW APARTMENT | 2127.60 | 2553.12 | 0.103 | 0.124 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F2 NW APARTMENT | 2133.33 | 2559.99 | 0.103 | 0.124 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F2 SE APARTMENT | 2139.13 | 2566.96 | 0.103 | 0.124 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F2 NE APARTMENT | 2129.36 | 2555.23 | 0.103 | 0.124 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F2 N1 APARTMENT | 1230.22 | 1476.26 | 0.060 | 0.071 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F2 N2 APARTMENT | 1230.12 | 1476.15 | 0.060 | 0.071 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F2 S1 APARTMENT | 1226.90 | 1472.29 | 0.059 | 0.071 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F2 S2 APARTMENT | 1227.79 | 1473.34 | 0.059 | 0.071 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F3 SW APARTMENT | 2127.04 | 2552.45 | 0.103 | 0.123 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F3 NW APARTMENT | 2132.95 | 2559.55 | 0.103 | 0.124 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F3 SE APARTMENT | 2125.50 | 2550.60 | 0.103 | 0.123 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F3 NE APARTMENT | 2129.79 | 2555.75 | 0.103 | 0.124 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F3 N1 APARTMENT | 1191.07 | 1429.29 | 0.058 | 0.069 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F3 N2 APARTMENT | 1190.99 | 1429.19 | 0.058 | 0.069 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F3 S1 APARTMENT | 1185.92 | 1423.10 | 0.057 | 0.069 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F3 S2 APARTMENT | 1185.99 | 1423.19 | 0.057 | 0.069 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F4 SW APARTMENT | 2183.01 | 2619.61 | 0.106 | 0.127 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F4 NW APARTMENT | 2188.34 | 2626.01 | 0.106 | 0.127 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F4 SE APARTMENT | 2180.75 | 2616.90 | 0.106 | 0.127 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F4 NE APARTMENT | 2185.92 | 2623.10 | 0.106 | 0.127 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F4 N1 APARTMENT | 1214.50 | 1457.41 | 0.059 | 0.071 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F4 N2 APARTMENT | 1214.45 | 1457.34 | 0.059 | 0.071 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F4 S1 APARTMENT | 1209.70 | 1451.65 | 0.059 | 0.070 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F4 S2 APARTMENT | 1209.67 | 1451.60 | 0.059 | 0.070 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
M SW APARTMENT | 2221.32 | 2665.59 | 0.107 | 0.129 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
M NW APARTMENT | 2224.91 | 2669.89 | 0.108 | 0.129 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
M SE APARTMENT | 2219.59 | 2663.51 | 0.107 | 0.129 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
M NE APARTMENT | 2223.16 | 2667.79 | 0.108 | 0.129 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
M N1 APARTMENT | 1225.73 | 1470.88 | 0.059 | 0.071 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
M N2 APARTMENT | 1225.69 | 1470.83 | 0.059 | 0.071 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
M S1 APARTMENT | 1222.66 | 1467.19 | 0.059 | 0.071 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
M S2 APARTMENT | 1222.62 | 1467.14 | 0.059 | 0.071 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F6 SW APARTMENT | 2307.06 | 2768.48 | 0.112 | 0.134 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F6 NW APARTMENT | 2310.45 | 2772.54 | 0.112 | 0.134 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F6 SE APARTMENT | 2305.92 | 2767.10 | 0.112 | 0.134 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F6 NE APARTMENT | 2309.31 | 2771.17 | 0.112 | 0.134 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F6 N1 APARTMENT | 1288.42 | 1546.10 | 0.062 | 0.075 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F6 N2 APARTMENT | 1288.39 | 1546.07 | 0.062 | 0.075 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F6 S1 APARTMENT | 1285.53 | 1542.64 | 0.062 | 0.075 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F6 S2 APARTMENT | 1285.50 | 1542.60 | 0.062 | 0.075 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F7 SW APARTMENT | 2369.03 | 2842.84 | 0.115 | 0.138 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F7 NW APARTMENT | 2371.37 | 2845.65 | 0.115 | 0.138 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F7 SE APARTMENT | 2368.44 | 2842.13 | 0.115 | 0.137 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F7 NE APARTMENT | 2370.78 | 2844.94 | 0.115 | 0.138 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F7 N1 APARTMENT | 1330.00 | 1595.99 | 0.064 | 0.077 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F7 N2 APARTMENT | 1329.98 | 1595.98 | 0.064 | 0.077 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F7 S1 APARTMENT | 1328.17 | 1593.81 | 0.064 | 0.077 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F7 S2 APARTMENT | 1328.16 | 1593.79 | 0.064 | 0.077 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F8 SW APARTMENT | 2435.47 | 2922.56 | 0.118 | 0.141 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F8 NW APARTMENT | 2436.58 | 2923.90 | 0.118 | 0.141 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F8 SE APARTMENT | 2435.38 | 2922.46 | 0.118 | 0.141 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F8 NE APARTMENT | 2436.50 | 2923.79 | 0.118 | 0.141 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F8 N1 APARTMENT | 1378.06 | 1653.67 | 0.067 | 0.080 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F8 N2 APARTMENT | 1378.06 | 1653.67 | 0.067 | 0.080 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F8 S1 APARTMENT | 1377.47 | 1652.97 | 0.067 | 0.080 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F8 S2 APARTMENT | 1377.47 | 1652.97 | 0.067 | 0.080 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F9 SW APARTMENT | 2626.92 | 3152.30 | 0.127 | 0.152 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F9 NW APARTMENT | 2624.47 | 3149.36 | 0.127 | 0.152 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F9 SE APARTMENT | 2627.30 | 3152.77 | 0.127 | 0.153 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F9 NE APARTMENT | 2624.85 | 3149.82 | 0.127 | 0.152 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F9 N1 APARTMENT | 1542.26 | 1850.72 | 0.075 | 0.090 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F9 N2 APARTMENT | 1542.27 | 1850.73 | 0.075 | 0.090 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F9 S1 APARTMENT | 1544.88 | 1853.85 | 0.075 | 0.090 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
F9 S2 APARTMENT | 1544.88 | 1853.86 | 0.075 | 0.090 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
T SW APARTMENT | 3299.66 | 3959.59 | 0.160 | 0.192 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
T NW APARTMENT | 3303.26 | 3963.91 | 0.160 | 0.192 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
T SE APARTMENT | 3300.39 | 3960.46 | 0.160 | 0.192 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
T NE APARTMENT | 3303.99 | 3964.79 | 0.160 | 0.192 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
T N1 APARTMENT | 2260.92 | 2713.10 | 0.109 | 0.131 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
T N2 APARTMENT | 2260.94 | 2713.12 | 0.109 | 0.131 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
T S1 APARTMENT | 2254.97 | 2705.96 | 0.109 | 0.131 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
T S2 APARTMENT | 2254.99 | 2705.98 | 0.109 | 0.131 | BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -16.30 | 0.00098 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
AIRLOOP G SW | 0.27 | 0.27 | 0.13 | 0.13 |
AIRLOOP G NW | 0.25 | 0.25 | 0.13 | 0.13 |
AIRLOOP OFFICE | 0.39 | 0.39 | 0.15 | 0.15 |
AIRLOOP G NE | 0.18 | 0.18 | 0.13 | 0.13 |
AIRLOOP G N1 | 0.12 | 0.12 | 0.09 | 0.09 |
AIRLOOP G N2 | 0.12 | 0.12 | 0.09 | 0.09 |
AIRLOOP G S1 | 0.16 | 0.16 | 0.09 | 0.09 |
AIRLOOP G S2 | 0.17 | 0.17 | 0.09 | 0.09 |
AIRLOOP F2 SW | 0.34 | 0.34 | 0.12 | 0.12 |
AIRLOOP F2 NW | 0.31 | 0.31 | 0.12 | 0.12 |
AIRLOOP F2 SE | 0.33 | 0.33 | 0.12 | 0.12 |
AIRLOOP F2 NE | 0.24 | 0.24 | 0.12 | 0.12 |
AIRLOOP F2 N1 | 0.16 | 0.16 | 0.07 | 0.07 |
AIRLOOP F2 N2 | 0.16 | 0.16 | 0.07 | 0.07 |
AIRLOOP F2 S1 | 0.21 | 0.21 | 0.07 | 0.07 |
AIRLOOP F2 S2 | 0.22 | 0.22 | 0.07 | 0.07 |
AIRLOOP F3 SW | 0.34 | 0.34 | 0.12 | 0.12 |
AIRLOOP F3 NW | 0.31 | 0.31 | 0.12 | 0.12 |
AIRLOOP F3 SE | 0.31 | 0.31 | 0.12 | 0.12 |
AIRLOOP F3 NE | 0.24 | 0.24 | 0.12 | 0.12 |
AIRLOOP F3 N1 | 0.16 | 0.16 | 0.07 | 0.07 |
AIRLOOP F3 N2 | 0.16 | 0.16 | 0.07 | 0.07 |
AIRLOOP F3 S1 | 0.22 | 0.22 | 0.07 | 0.07 |
AIRLOOP F3 S2 | 0.22 | 0.22 | 0.07 | 0.07 |
AIRLOOP F4 SW | 0.35 | 0.35 | 0.13 | 0.13 |
AIRLOOP F4 NW | 0.32 | 0.32 | 0.13 | 0.13 |
AIRLOOP F4 SE | 0.31 | 0.31 | 0.13 | 0.13 |
AIRLOOP F4 NE | 0.25 | 0.25 | 0.13 | 0.13 |
AIRLOOP F4 N1 | 0.17 | 0.17 | 0.07 | 0.07 |
AIRLOOP F4 N2 | 0.16 | 0.16 | 0.07 | 0.07 |
AIRLOOP F4 S1 | 0.22 | 0.22 | 0.07 | 0.07 |
AIRLOOP F4 S2 | 0.22 | 0.22 | 0.07 | 0.07 |
AIRLOOP M SW | 0.35 | 0.35 | 0.13 | 0.13 |
AIRLOOP M NW | 0.32 | 0.32 | 0.13 | 0.13 |
AIRLOOP M SE | 0.32 | 0.32 | 0.13 | 0.13 |
AIRLOOP M NE | 0.25 | 0.25 | 0.13 | 0.13 |
AIRLOOP M N1 | 0.17 | 0.17 | 0.07 | 0.07 |
AIRLOOP M N2 | 0.17 | 0.17 | 0.07 | 0.07 |
AIRLOOP M S1 | 0.23 | 0.23 | 0.07 | 0.07 |
AIRLOOP M S2 | 0.23 | 0.23 | 0.07 | 0.07 |
AIRLOOP F6 SW | 0.35 | 0.35 | 0.13 | 0.13 |
AIRLOOP F6 NW | 0.32 | 0.32 | 0.13 | 0.13 |
AIRLOOP F6 SE | 0.32 | 0.32 | 0.13 | 0.13 |
AIRLOOP F6 NE | 0.25 | 0.25 | 0.13 | 0.13 |
AIRLOOP F6 N1 | 0.17 | 0.17 | 0.07 | 0.07 |
AIRLOOP F6 N2 | 0.17 | 0.17 | 0.07 | 0.07 |
AIRLOOP F6 S1 | 0.23 | 0.23 | 0.07 | 0.07 |
AIRLOOP F6 S2 | 0.23 | 0.23 | 0.07 | 0.07 |
AIRLOOP F7 SW | 0.35 | 0.35 | 0.14 | 0.14 |
AIRLOOP F7 NW | 0.32 | 0.32 | 0.14 | 0.14 |
AIRLOOP F7 SE | 0.32 | 0.32 | 0.14 | 0.14 |
AIRLOOP F7 NE | 0.25 | 0.25 | 0.14 | 0.14 |
AIRLOOP F7 N1 | 0.17 | 0.17 | 0.08 | 0.08 |
AIRLOOP F7 N2 | 0.17 | 0.17 | 0.08 | 0.08 |
AIRLOOP F7 S1 | 0.23 | 0.23 | 0.08 | 0.08 |
AIRLOOP F7 S2 | 0.23 | 0.23 | 0.08 | 0.08 |
AIRLOOP F8 SW | 0.35 | 0.35 | 0.14 | 0.14 |
AIRLOOP F8 NW | 0.32 | 0.32 | 0.14 | 0.14 |
AIRLOOP F8 SE | 0.32 | 0.32 | 0.14 | 0.14 |
AIRLOOP F8 NE | 0.25 | 0.25 | 0.14 | 0.14 |
AIRLOOP F8 N1 | 0.17 | 0.17 | 0.08 | 0.08 |
AIRLOOP F8 N2 | 0.17 | 0.17 | 0.08 | 0.08 |
AIRLOOP F8 S1 | 0.23 | 0.23 | 0.08 | 0.08 |
AIRLOOP F8 S2 | 0.23 | 0.23 | 0.08 | 0.08 |
AIRLOOP F9 SW | 0.36 | 0.36 | 0.15 | 0.15 |
AIRLOOP F9 NW | 0.33 | 0.33 | 0.15 | 0.15 |
AIRLOOP F9 SE | 0.33 | 0.33 | 0.15 | 0.15 |
AIRLOOP F9 NE | 0.26 | 0.26 | 0.15 | 0.15 |
AIRLOOP F9 N1 | 0.18 | 0.18 | 0.09 | 0.09 |
AIRLOOP F9 N2 | 0.18 | 0.18 | 0.09 | 0.09 |
AIRLOOP F9 S1 | 0.23 | 0.23 | 0.09 | 0.09 |
AIRLOOP F9 S2 | 0.24 | 0.24 | 0.09 | 0.09 |
AIRLOOP T SW | 0.45 | 0.45 | 0.19 | 0.19 |
AIRLOOP T NW | 0.41 | 0.41 | 0.19 | 0.19 |
AIRLOOP T SE | 0.41 | 0.41 | 0.19 | 0.19 |
AIRLOOP T NE | 0.32 | 0.32 | 0.19 | 0.19 |
AIRLOOP T N1 | 0.24 | 0.24 | 0.13 | 0.13 |
AIRLOOP T N2 | 0.24 | 0.24 | 0.13 | 0.13 |
AIRLOOP T S1 | 0.33 | 0.33 | 0.13 | 0.13 |
AIRLOOP T S2 | 0.33 | 0.33 | 0.13 | 0.13 |
Report: System Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:31
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 1766.00 | 5679.50 | 170.25 |
G NW APARTMENT | 1557.25 | 6419.00 | 413.50 |
OFFICE | 879.25 | 858.00 | 15.50 |
G NE APARTMENT | 1632.00 | 6364.25 | 434.75 |
G N1 APARTMENT | 977.25 | 6746.25 | 106.75 |
G N2 APARTMENT | 981.75 | 6747.00 | 108.75 |
G S1 APARTMENT | 1340.75 | 5917.25 | 44.75 |
G S2 APARTMENT | 1390.50 | 5821.75 | 41.50 |
F2 SW APARTMENT | 2469.50 | 4280.25 | 38.75 |
F2 NW APARTMENT | 1799.00 | 5409.00 | 131.25 |
F2 SE APARTMENT | 2794.75 | 4002.75 | 28.50 |
F2 NE APARTMENT | 1926.00 | 5450.25 | 148.50 |
F2 N1 APARTMENT | 1321.00 | 5812.00 | 22.50 |
F2 N2 APARTMENT | 1324.75 | 5816.50 | 22.50 |
F2 S1 APARTMENT | 2167.75 | 4143.50 | 7.75 |
F2 S2 APARTMENT | 2205.50 | 4092.50 | 7.75 |
F3 SW APARTMENT | 2649.50 | 4052.00 | 30.50 |
F3 NW APARTMENT | 1907.00 | 5182.75 | 105.00 |
F3 SE APARTMENT | 2782.00 | 3994.25 | 29.25 |
F3 NE APARTMENT | 2020.00 | 5249.50 | 122.25 |
F3 N1 APARTMENT | 1455.50 | 5487.25 | 17.75 |
F3 N2 APARTMENT | 1456.00 | 5485.75 | 17.75 |
F3 S1 APARTMENT | 2451.00 | 3703.50 | 7.00 |
F3 S2 APARTMENT | 2469.25 | 3686.50 | 7.00 |
F4 SW APARTMENT | 2665.25 | 4046.50 | 30.25 |
F4 NW APARTMENT | 1926.50 | 5146.75 | 105.75 |
F4 SE APARTMENT | 2771.50 | 4020.75 | 31.50 |
F4 NE APARTMENT | 2039.00 | 5218.00 | 122.75 |
F4 N1 APARTMENT | 1489.50 | 5384.50 | 16.00 |
F4 N2 APARTMENT | 1491.50 | 5388.50 | 16.50 |
F4 S1 APARTMENT | 2520.50 | 3646.25 | 7.00 |
F4 S2 APARTMENT | 2532.00 | 3637.25 | 7.00 |
M SW APARTMENT | 2668.75 | 4062.75 | 28.75 |
M NW APARTMENT | 1940.75 | 5149.50 | 103.75 |
M SE APARTMENT | 2768.25 | 4043.75 | 30.75 |
M NE APARTMENT | 2049.50 | 5221.50 | 117.50 |
M N1 APARTMENT | 1514.75 | 5358.25 | 14.25 |
M N2 APARTMENT | 1519.00 | 5363.50 | 14.25 |
M S1 APARTMENT | 2549.75 | 3639.00 | 6.75 |
M S2 APARTMENT | 2559.50 | 3634.25 | 6.75 |
F6 SW APARTMENT | 2549.25 | 4213.00 | 36.25 |
F6 NW APARTMENT | 1868.75 | 5277.00 | 130.50 |
F6 SE APARTMENT | 2656.25 | 4181.25 | 39.75 |
F6 NE APARTMENT | 1961.00 | 5355.25 | 143.50 |
F6 N1 APARTMENT | 1430.00 | 5527.25 | 18.00 |
F6 N2 APARTMENT | 1431.00 | 5533.75 | 18.00 |
F6 S1 APARTMENT | 2388.00 | 3818.25 | 7.25 |
F6 S2 APARTMENT | 2396.25 | 3812.75 | 7.25 |
F7 SW APARTMENT | 2463.50 | 4312.75 | 39.75 |
F7 NW APARTMENT | 1819.00 | 5386.25 | 144.50 |
F7 SE APARTMENT | 2586.75 | 4294.25 | 44.00 |
F7 NE APARTMENT | 1909.25 | 5451.25 | 155.00 |
F7 N1 APARTMENT | 1385.00 | 5647.75 | 19.00 |
F7 N2 APARTMENT | 1382.50 | 5653.25 | 19.00 |
F7 S1 APARTMENT | 2298.25 | 3961.00 | 7.50 |
F7 S2 APARTMENT | 2304.50 | 3957.50 | 7.50 |
F8 SW APARTMENT | 2397.50 | 4404.50 | 45.50 |
F8 NW APARTMENT | 1795.00 | 5473.50 | 160.00 |
F8 SE APARTMENT | 2533.00 | 4395.75 | 50.75 |
F8 NE APARTMENT | 1869.00 | 5532.25 | 170.50 |
F8 N1 APARTMENT | 1357.25 | 5738.00 | 21.50 |
F8 N2 APARTMENT | 1357.25 | 5746.75 | 22.25 |
F8 S1 APARTMENT | 2224.25 | 4103.00 | 7.50 |
F8 S2 APARTMENT | 2237.50 | 4101.25 | 7.50 |
F9 SW APARTMENT | 2345.00 | 4540.25 | 77.00 |
F9 NW APARTMENT | 1838.50 | 5582.50 | 228.50 |
F9 SE APARTMENT | 2481.25 | 4525.25 | 84.00 |
F9 NE APARTMENT | 1912.50 | 5631.25 | 245.25 |
F9 N1 APARTMENT | 1365.25 | 5832.00 | 36.25 |
F9 N2 APARTMENT | 1366.75 | 5833.50 | 36.50 |
F9 S1 APARTMENT | 2114.75 | 4316.00 | 7.25 |
F9 S2 APARTMENT | 2124.75 | 4308.00 | 7.25 |
T SW APARTMENT | 2950.50 | 5136.00 | 676.50 |
T NW APARTMENT | 2753.25 | 5917.75 | 1060.25 |
T SE APARTMENT | 3072.50 | 5060.50 | 680.75 |
T NE APARTMENT | 2886.25 | 5911.75 | 1060.50 |
T N1 APARTMENT | 1914.25 | 6075.00 | 462.75 |
T N2 APARTMENT | 1923.75 | 6067.25 | 464.25 |
T S1 APARTMENT | 2410.25 | 4892.50 | 212.50 |
T S2 APARTMENT | 2427.00 | 4892.00 | 213.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 4534.50 | 6916.25 | 1144.50 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 1.75 | 49.25 | 1.75 | 49.25 |
G NW APARTMENT | 0.00 | 30.00 | 0.00 | 30.00 |
OFFICE | 1.50 | 2.75 | 0.00 | 2.75 |
G NE APARTMENT | 1.75 | 13.75 | 1.75 | 13.75 |
G N1 APARTMENT | 4.75 | 62.25 | 4.75 | 62.25 |
G N2 APARTMENT | 7.25 | 65.50 | 7.25 | 65.50 |
G S1 APARTMENT | 2.50 | 43.00 | 2.50 | 43.00 |
G S2 APARTMENT | 3.00 | 30.50 | 3.00 | 30.50 |
F2 SW APARTMENT | 0.25 | 47.75 | 0.25 | 47.75 |
F2 NW APARTMENT | 0.25 | 25.75 | 0.25 | 25.75 |
F2 SE APARTMENT | 2.50 | 0.00 | 2.50 | 0.00 |
F2 NE APARTMENT | 1.50 | 12.25 | 1.50 | 12.25 |
F2 N1 APARTMENT | 6.00 | 46.50 | 6.00 | 46.50 |
F2 N2 APARTMENT | 7.50 | 49.50 | 7.50 | 49.50 |
F2 S1 APARTMENT | 2.25 | 60.00 | 2.25 | 60.00 |
F2 S2 APARTMENT | 2.00 | 54.25 | 2.00 | 54.25 |
F3 SW APARTMENT | 0.50 | 53.75 | 0.50 | 53.75 |
F3 NW APARTMENT | 0.25 | 30.25 | 0.25 | 30.25 |
F3 SE APARTMENT | 1.25 | 10.75 | 1.25 | 10.75 |
F3 NE APARTMENT | 1.00 | 17.50 | 1.00 | 17.50 |
F3 N1 APARTMENT | 5.25 | 60.00 | 5.25 | 60.00 |
F3 N2 APARTMENT | 6.25 | 63.00 | 6.25 | 63.00 |
F3 S1 APARTMENT | 4.25 | 68.00 | 4.25 | 68.00 |
F3 S2 APARTMENT | 4.75 | 63.50 | 4.75 | 63.50 |
F4 SW APARTMENT | 0.50 | 57.00 | 0.50 | 57.00 |
F4 NW APARTMENT | 1.00 | 33.00 | 1.00 | 33.00 |
F4 SE APARTMENT | 1.75 | 13.25 | 1.75 | 13.25 |
F4 NE APARTMENT | 1.25 | 20.50 | 1.25 | 20.50 |
F4 N1 APARTMENT | 4.25 | 69.25 | 4.25 | 69.25 |
F4 N2 APARTMENT | 5.50 | 71.50 | 5.50 | 71.50 |
F4 S1 APARTMENT | 2.50 | 66.75 | 2.50 | 66.75 |
F4 S2 APARTMENT | 3.00 | 62.75 | 3.00 | 62.75 |
M SW APARTMENT | 0.75 | 60.50 | 0.75 | 60.50 |
M NW APARTMENT | 0.00 | 36.00 | 0.00 | 36.00 |
M SE APARTMENT | 1.00 | 13.00 | 1.00 | 13.00 |
M NE APARTMENT | 1.25 | 24.00 | 1.25 | 24.00 |
M N1 APARTMENT | 5.25 | 72.50 | 5.25 | 72.50 |
M N2 APARTMENT | 5.00 | 74.75 | 5.00 | 74.75 |
M S1 APARTMENT | 2.50 | 63.25 | 2.50 | 63.25 |
M S2 APARTMENT | 3.25 | 61.00 | 3.25 | 61.00 |
F6 SW APARTMENT | 0.25 | 62.50 | 0.25 | 62.50 |
F6 NW APARTMENT | 0.25 | 38.50 | 0.25 | 38.50 |
F6 SE APARTMENT | 1.00 | 13.25 | 1.00 | 13.25 |
F6 NE APARTMENT | 1.25 | 27.25 | 1.25 | 27.25 |
F6 N1 APARTMENT | 5.75 | 77.25 | 5.75 | 77.25 |
F6 N2 APARTMENT | 6.50 | 79.75 | 6.50 | 79.75 |
F6 S1 APARTMENT | 3.25 | 62.00 | 3.25 | 62.00 |
F6 S2 APARTMENT | 2.75 | 58.50 | 2.75 | 58.50 |
F7 SW APARTMENT | 0.50 | 65.00 | 0.50 | 65.00 |
F7 NW APARTMENT | 0.25 | 40.00 | 0.25 | 40.00 |
F7 SE APARTMENT | 1.25 | 14.25 | 1.25 | 14.25 |
F7 NE APARTMENT | 0.50 | 30.75 | 0.50 | 30.75 |
F7 N1 APARTMENT | 5.00 | 81.25 | 5.00 | 81.25 |
F7 N2 APARTMENT | 5.50 | 85.00 | 5.50 | 85.00 |
F7 S1 APARTMENT | 2.50 | 58.25 | 2.50 | 58.25 |
F7 S2 APARTMENT | 2.75 | 56.50 | 2.75 | 56.50 |
F8 SW APARTMENT | 0.25 | 67.25 | 0.25 | 67.25 |
F8 NW APARTMENT | 0.25 | 40.50 | 0.25 | 40.50 |
F8 SE APARTMENT | 0.25 | 13.50 | 0.25 | 13.50 |
F8 NE APARTMENT | 1.25 | 33.50 | 1.25 | 33.50 |
F8 N1 APARTMENT | 6.00 | 82.50 | 6.00 | 82.50 |
F8 N2 APARTMENT | 6.00 | 87.25 | 6.00 | 87.25 |
F8 S1 APARTMENT | 4.25 | 55.50 | 4.25 | 55.50 |
F8 S2 APARTMENT | 4.25 | 53.25 | 4.25 | 53.25 |
F9 SW APARTMENT | 0.50 | 58.25 | 0.50 | 58.25 |
F9 NW APARTMENT | 0.00 | 39.75 | 0.00 | 39.75 |
F9 SE APARTMENT | 0.25 | 9.25 | 0.25 | 9.25 |
F9 NE APARTMENT | 1.00 | 43.75 | 1.00 | 43.75 |
F9 N1 APARTMENT | 3.00 | 72.75 | 3.00 | 72.75 |
F9 N2 APARTMENT | 4.25 | 75.50 | 4.25 | 75.50 |
F9 S1 APARTMENT | 2.75 | 48.00 | 2.75 | 48.00 |
F9 S2 APARTMENT | 4.25 | 45.75 | 4.25 | 45.75 |
T SW APARTMENT | 0.00 | 27.50 | 0.00 | 27.50 |
T NW APARTMENT | 0.00 | 34.25 | 0.00 | 34.25 |
T SE APARTMENT | 0.00 | 2.25 | 0.00 | 2.25 |
T NE APARTMENT | 0.00 | 13.00 | 0.00 | 13.00 |
T N1 APARTMENT | 0.25 | 27.75 | 0.25 | 27.75 |
T N2 APARTMENT | 0.00 | 22.25 | 0.00 | 22.25 |
T S1 APARTMENT | 1.00 | 12.50 | 1.00 | 12.50 |
T S2 APARTMENT | 0.50 | 12.25 | 0.50 | 12.25 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 134.50 | 179.25 | 133.00 | 179.25 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:31
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.152 | 0.000 | 0.245 |
G NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.152 | 0.000 | 0.234 |
OFFICE | 0.94 | 1.00 | 268.96 | 0.529 | 0.164 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.152 | 0.000 | 0.235 |
G N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.092 | 0.000 | 0.227 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.092 | 0.000 | 0.227 |
G S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.092 | 0.000 | 0.242 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.092 | 0.000 | 0.243 |
F2 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.361 | 0.219 | 0.000 | 0.278 |
F2 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.218 | 0.000 | 0.267 |
F2 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.361 | 0.219 | 0.000 | 0.279 |
F2 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.218 | 0.000 | 0.267 |
F2 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.132 | 0.000 | 0.262 |
F2 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.132 | 0.000 | 0.262 |
F2 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.361 | 0.132 | 0.000 | 0.276 |
F2 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.361 | 0.132 | 0.000 | 0.276 |
F3 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.361 | 0.259 | 0.000 | 0.300 |
F3 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.259 | 0.000 | 0.289 |
F3 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.361 | 0.259 | 0.000 | 0.301 |
F3 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.258 | 0.000 | 0.289 |
F3 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.156 | 0.000 | 0.285 |
F3 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.156 | 0.000 | 0.285 |
F3 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.361 | 0.156 | 0.000 | 0.299 |
F3 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.361 | 0.156 | 0.000 | 0.299 |
F4 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.361 | 0.289 | 0.000 | 0.308 |
F4 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.289 | 0.000 | 0.296 |
F4 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.361 | 0.289 | 0.000 | 0.309 |
F4 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.289 | 0.000 | 0.297 |
F4 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.174 | 0.000 | 0.293 |
F4 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.174 | 0.000 | 0.293 |
F4 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.361 | 0.175 | 0.000 | 0.307 |
F4 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.361 | 0.175 | 0.000 | 0.307 |
M SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.361 | 0.314 | 0.000 | 0.321 |
M NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.314 | 0.000 | 0.308 |
M SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.361 | 0.314 | 0.000 | 0.321 |
M NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.314 | 0.000 | 0.308 |
M N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.189 | 0.000 | 0.304 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.189 | 0.000 | 0.305 |
M S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.361 | 0.190 | 0.000 | 0.320 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.361 | 0.190 | 0.000 | 0.320 |
F6 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.336 | 0.000 | 0.331 |
F6 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.335 | 0.000 | 0.318 |
F6 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.336 | 0.000 | 0.332 |
F6 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.335 | 0.000 | 0.318 |
F6 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.202 | 0.000 | 0.314 |
F6 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.202 | 0.000 | 0.314 |
F6 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.361 | 0.203 | 0.000 | 0.330 |
F6 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.361 | 0.203 | 0.000 | 0.330 |
F7 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.355 | 0.000 | 0.340 |
F7 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.354 | 0.000 | 0.326 |
F7 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.355 | 0.000 | 0.341 |
F7 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.354 | 0.000 | 0.326 |
F7 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.214 | 0.000 | 0.322 |
F7 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.214 | 0.000 | 0.322 |
F7 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.361 | 0.214 | 0.000 | 0.339 |
F7 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.361 | 0.214 | 0.000 | 0.339 |
F8 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.372 | 0.000 | 0.350 |
F8 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.371 | 0.000 | 0.335 |
F8 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.372 | 0.000 | 0.350 |
F8 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.371 | 0.000 | 0.335 |
F8 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.224 | 0.000 | 0.331 |
F8 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.224 | 0.000 | 0.331 |
F8 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.361 | 0.224 | 0.000 | 0.349 |
F8 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.361 | 0.224 | 0.000 | 0.349 |
F9 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.388 | 0.000 | 0.358 |
F9 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.387 | 0.000 | 0.342 |
F9 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.388 | 0.000 | 0.359 |
F9 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.387 | 0.000 | 0.343 |
F9 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.233 | 0.000 | 0.338 |
F9 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.233 | 0.000 | 0.338 |
F9 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.361 | 0.234 | 0.000 | 0.357 |
F9 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.361 | 0.234 | 0.000 | 0.357 |
T SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.402 | 0.000 | 0.363 |
T NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.402 | 0.000 | 0.349 |
T SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.402 | 0.000 | 0.365 |
T NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.402 | 0.000 | 0.349 |
T N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.242 | 0.000 | 0.345 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.242 | 0.000 | 0.346 |
T S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.360 | 0.242 | 0.000 | 0.363 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.360 | 0.242 | 0.000 | 0.363 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.96 | 0.512 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
F2 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F2 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F2 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F2 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F2 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F2 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
F2 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F2 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
F3 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F3 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F3 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F3 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F3 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F3 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
F3 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F3 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
F4 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F4 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F4 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F4 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F4 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F4 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
F4 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F4 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
F6 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F6 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F6 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F6 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F6 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F6 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
F6 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F6 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
F7 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F7 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F7 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F7 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F7 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F7 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
F7 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F7 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
F8 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F8 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F8 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F8 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F8 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F8 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
F8 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F8 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
F9 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F9 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F9 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F9 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F9 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F9 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
F9 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
F9 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.348 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.348 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:31
Surfaces by ClassTotal | Outdoors | |
Wall | 420 | 140 |
Floor | 90 | 9 |
Roof | 90 | 9 |
Internal Mass | 80 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 140 | 140 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 80 |
Conditioned Zones | 80 |
Unconditioned Zones | 10 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 4156 |
Defaulted Fields | 814 |
Fields with Defaults | 11184 |
Autosized Fields | 1293 |
Autosizable Fields | 1630 |
Autocalculated Fields | 907 |
Autocalculatable Fields | 1710 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2015-09-09 19:00:31
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 2969.94 | 60621.67 | 15-MAY-02:45 | 171034.84 | 31-JUL-18:00 |
Electricity:Building | 1433.88 | 25760.85 | 01-JAN-03:15 | 70162.48 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity | 296.56 | 6715.87 | 01-JAN-00:15 | 14401.37 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 242.55 | 5824.91 | 01-JAN-00:15 | 11484.27 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 39.38 | 663.42 | 01-JAN-00:15 | 2934.49 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 29.88 | 469.18 | 01-JAN-00:15 | 2345.88 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F2 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F2 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F3 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F3 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F4 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F4 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:M SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M CORRIDOR | 32.88 | 1042.61 | 01-JAN-00:15 | 1042.61 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 32.88 | 1042.61 | 01-JAN-00:15 | 1042.61 | 01-JAN-00:15 |
Electricity:Zone:F6 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F6 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F7 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F7 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F8 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F8 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F9 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F9 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:T SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T CORRIDOR | 179.47 | 1701.70 | 01-JAN-00:15 | 10868.20 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 54.01 | 890.97 | 01-JAN-00:15 | 2917.11 | 01-JAN-19:15 |
InteriorEquipment:Electricity | 1137.32 | 19044.98 | 01-JAN-03:15 | 57142.09 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 1137.32 | 19044.98 | 01-JAN-03:15 | 57142.09 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 9.50 | 194.24 | 01-JAN-00:15 | 588.62 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T CORRIDOR | 163.03 | 1180.40 | 01-JAN-00:15 | 10346.90 | 01-JAN-07:15 |
Fans:Electricity | 750.51 | 23798.64 | 01-JAN-01:00 | 23798.64 | 01-JAN-00:15 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Electricity:HVAC | 1299.78 | 24459.89 | 15-MAY-02:45 | 96703.75 | 04-AUG-16:15 |
ElectricityProduced:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityProduced:HVAC | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricityProduced | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 2969.94 | 60621.67 | 15-MAY-02:45 | 171034.84 | 31-JUL-18:00 |
ElectricityPurchased:Plant | 2969.94 | 60621.67 | 15-MAY-02:45 | 171034.84 | 31-JUL-18:00 |
Cogeneration:ElectricityPurchased | 2969.94 | 60621.67 | 15-MAY-02:45 | 171034.84 | 31-JUL-18:00 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 2969.94 | 60621.67 | 15-MAY-02:45 | 171034.84 | 31-JUL-18:00 |
ElectricityNet:Plant | 2969.94 | 60621.67 | 15-MAY-02:45 | 171034.84 | 31-JUL-18:00 |
Cogeneration:ElectricityNet | 2969.94 | 60621.67 | 15-MAY-02:45 | 171034.84 | 31-JUL-18:00 |
ExteriorLights:Electricity | 162.61 | 0.00 | 01-JAN-08:30 | 10364.00 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 162.61 | 0.00 | 01-JAN-08:30 | 10364.00 | 01-JAN-00:15 |
General:Fans:Electricity | 750.51 | 23798.64 | 01-JAN-01:00 | 23798.64 | 01-JAN-00:15 |
Cooling:Electricity | 353.52 | 0.00 | 01-JAN-00:15 | 70909.91 | 04-AUG-16:15 |
Heating:Electricity | 159.58 | 0.00 | 10-FEB-15:00 | 47114.35 | 04-JAN-05:00 |
Electricity:Plant | 73.67 | 36.93 | 03-MAR-18:45 | 4489.15 | 31-JUL-17:00 |
HeatRejection:Electricity | 12.51 | 0.00 | 01-JAN-00:15 | 2523.38 | 31-JUL-17:00 |
Boiler Parasitic:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Pumps:Electricity | 61.16 | 36.93 | 03-MAR-18:45 | 1965.77 | 01-JAN-06:15 |
WIRED_LTG_ELECTRICITY | 0.44 | 0.00 | 01-JAN-00:15 | 21.60 | 01-JAN-19:30 |
WIRED_INT_EQUIP | 979.40 | 1018.50 | 01-JAN-00:15 | 10185.00 | 01-JAN-07:15 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 1709.56 | 2357.00 | 08-FEB-00:15 | 268387.14 | 28-DEC-08:15 |
Gas:Plant | 1709.56 | 2357.00 | 08-FEB-00:15 | 268387.14 | 28-DEC-08:15 |
WaterSystems:Gas | 1165.01 | 2357.00 | 01-JAN-00:15 | 83068.13 | 15-FEB-08:00 |
Water Heater:WaterSystems:Gas | 1165.01 | 2357.00 | 01-JAN-00:15 | 83068.13 | 15-FEB-08:00 |
Heating:Gas | 544.55 | 0.00 | 26-JAN-13:45 | 193240.80 | 04-JAN-05:15 |
Boiler:Heating:Gas | 544.55 | 0.00 | 26-JAN-13:45 | 193240.80 | 04-JAN-05:15 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
PlantLoopCoolingDemand:Facility | 1395.21 | 0.00 | 01-JAN-00:15 | 322183.83 | 31-JUL-18:00 |
PlantLoopCoolingDemand:HVAC | 1395.21 | 0.00 | 01-JAN-00:15 | 322183.83 | 31-JUL-18:00 |
CoolingCoils:PlantLoopCoolingDemand | 1395.21 | 0.00 | 01-JAN-00:15 | 322183.83 | 31-JUL-18:00 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 6069.22 | 0.00 | 01-JAN-02:15 | 0.00 | 21-JUL-17:30 |
Water:Plant | 6069.22 | 0.00 | 01-JAN-02:15 | 0.00 | 21-JUL-17:30 |
WaterSystems:Water | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:Water | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
MainsWater:Facility | 6069.22 | 0.00 | 01-JAN-02:15 | 0.00 | 21-JUL-17:30 |
MainsWater:Plant | 6069.22 | 0.00 | 01-JAN-02:15 | 0.00 | 21-JUL-17:30 |
WaterSystems:MainsWater | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:MainsWater | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
sub cat:WaterSystems:Water | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
sub cat:WaterSystems:MainsWater | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
HeatRejection:Water | 1290.70 | 0.00 | 01-JAN-00:15 | 0.00 | 21-JUL-17:30 |
HeatRejection:MainsWater | 1290.70 | 0.00 | 01-JAN-00:15 | 0.00 | 21-JUL-17:30 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 1355.76 | 461.65 | 19-AUG-01:15 | 204301.12 | 04-JAN-08:00 |
PlantLoopHeatingDemand:Plant | 906.75 | 461.65 | 19-AUG-01:15 | 62523.17 | 14-FEB-07:30 |
WaterSystems:PlantLoopHeatingDemand | 906.75 | 461.65 | 19-AUG-01:15 | 62523.17 | 14-FEB-07:30 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 4386.69 | 6293.58 | 29-OCT-01:15 | 535247.24 | 28-DEC-08:15 |
EnergyTransfer:Building | 1416.65 | 4509.90 | 27-OCT-18:00 | 201289.76 | 06-AUG-16:15 |
EnergyTransfer:Zone:G SW APARTMENT | 15.37 | 0.04 | 07-SEP-04:00 | 2833.04 | 30-SEP-16:15 |
Heating:EnergyTransfer | 391.14 | 0.00 | 05-FEB-17:00 | 152529.46 | 04-JAN-05:00 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 5.10 | 0.00 | 01-JAN-13:15 | 1828.68 | 04-JAN-08:15 |
Cooling:EnergyTransfer | 1025.51 | 0.00 | 01-JAN-00:15 | 201289.76 | 06-AUG-16:15 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 10.28 | 0.00 | 01-JAN-00:15 | 2833.04 | 30-SEP-16:15 |
EnergyTransfer:Zone:G NW APARTMENT | 14.76 | 0.02 | 08-MAY-01:30 | 2517.62 | 08-JUL-19:15 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 8.08 | 0.00 | 23-JAN-16:30 | 1906.80 | 13-JAN-08:30 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 6.69 | 0.00 | 01-JAN-00:15 | 2517.62 | 08-JUL-19:15 |
EnergyTransfer:Zone:OFFICE | 23.51 | 0.00 | 17-OCT-03:00 | 3980.29 | 28-SEP-14:15 |
Heating:EnergyTransfer:Zone:OFFICE | 3.73 | 0.00 | 01-JAN-13:15 | 1724.49 | 28-DEC-08:00 |
Cooling:EnergyTransfer:Zone:OFFICE | 19.78 | 0.00 | 01-JAN-00:15 | 3980.29 | 28-SEP-14:15 |
EnergyTransfer:Zone:G NE APARTMENT | 14.57 | 0.02 | 13-OCT-04:15 | 1900.04 | 04-JAN-08:15 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 7.76 | 0.00 | 05-FEB-16:45 | 1900.04 | 04-JAN-08:15 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 6.81 | 0.00 | 01-JAN-00:15 | 1819.82 | 22-JUL-08:30 |
EnergyTransfer:Zone:G N1 APARTMENT | 9.35 | 0.02 | 03-MAY-09:15 | 1290.07 | 03-MAR-13:45 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 4.18 | 0.00 | 30-JAN-17:15 | 1290.07 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 5.17 | 0.00 | 01-JAN-00:15 | 1275.22 | 08-JUL-19:30 |
EnergyTransfer:Zone:G N2 APARTMENT | 9.35 | 0.01 | 26-MAY-13:15 | 1289.18 | 03-MAR-13:45 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 4.18 | 0.00 | 30-JAN-17:15 | 1289.18 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 5.18 | 0.00 | 01-JAN-00:15 | 1254.90 | 08-JUL-19:30 |
EnergyTransfer:Zone:G S1 APARTMENT | 11.02 | 0.00 | 09-DEC-05:30 | 1918.13 | 31-AUG-13:45 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 1.80 | 0.00 | 01-JAN-12:45 | 1091.19 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 9.21 | 0.00 | 01-JAN-00:15 | 1918.13 | 31-AUG-13:45 |
EnergyTransfer:Zone:G S2 APARTMENT | 11.18 | 0.01 | 14-JUL-06:00 | 1989.72 | 31-AUG-13:45 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 1.70 | 0.00 | 01-JAN-12:45 | 1077.52 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 9.47 | 0.00 | 01-JAN-00:15 | 1989.72 | 31-AUG-13:45 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F2 SW APARTMENT | 20.49 | 0.04 | 19-APR-22:15 | 3563.28 | 30-SEP-16:15 |
Heating:EnergyTransfer:Zone:F2 SW APARTMENT | 3.60 | 0.00 | 01-JAN-13:15 | 1902.90 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT | 16.89 | 0.00 | 01-JAN-00:15 | 3563.28 | 30-SEP-16:15 |
EnergyTransfer:Zone:F2 NW APARTMENT | 17.42 | 0.00 | 16-SEP-00:45 | 3207.17 | 14-JUL-18:30 |
Heating:EnergyTransfer:Zone:F2 NW APARTMENT | 6.89 | 0.00 | 23-JAN-16:15 | 2120.36 | 28-DEC-10:00 |
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT | 10.53 | 0.00 | 01-JAN-00:15 | 3207.17 | 14-JUL-18:30 |
EnergyTransfer:Zone:F2 SE APARTMENT | 21.75 | 0.02 | 29-DEC-21:15 | 3439.50 | 28-SEP-14:15 |
Heating:EnergyTransfer:Zone:F2 SE APARTMENT | 3.04 | 0.00 | 01-JAN-13:15 | 1846.07 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT | 18.71 | 0.00 | 01-JAN-00:15 | 3439.50 | 28-SEP-14:15 |
EnergyTransfer:Zone:F2 NE APARTMENT | 17.46 | 0.01 | 09-MAY-17:45 | 2412.48 | 13-JUL-10:15 |
Heating:EnergyTransfer:Zone:F2 NE APARTMENT | 6.62 | 0.00 | 20-JAN-19:00 | 2042.40 | 04-JAN-05:00 |
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT | 10.84 | 0.00 | 01-JAN-00:15 | 2412.48 | 13-JUL-10:15 |
EnergyTransfer:Zone:F2 N1 APARTMENT | 10.75 | 0.01 | 09-JAN-18:30 | 1695.73 | 08-JUL-19:30 |
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT | 2.48 | 0.00 | 03-JAN-17:15 | 1536.03 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT | 8.27 | 0.00 | 01-JAN-00:15 | 1695.73 | 08-JUL-19:30 |
EnergyTransfer:Zone:F2 N2 APARTMENT | 10.77 | 0.04 | 13-FEB-12:30 | 1679.02 | 08-JUL-19:30 |
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT | 2.48 | 0.00 | 03-JAN-17:15 | 1533.57 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT | 8.29 | 0.00 | 01-JAN-00:15 | 1679.02 | 08-JUL-19:30 |
EnergyTransfer:Zone:F2 S1 APARTMENT | 16.22 | 0.06 | 05-MAY-10:30 | 2452.95 | 31-AUG-13:30 |
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT | 0.87 | 0.00 | 01-JAN-09:45 | 966.29 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT | 15.35 | 0.00 | 01-JAN-00:15 | 2452.95 | 31-AUG-13:30 |
EnergyTransfer:Zone:F2 S2 APARTMENT | 16.36 | 0.07 | 21-DEC-02:30 | 2479.44 | 31-AUG-13:30 |
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT | 0.85 | 0.00 | 01-JAN-09:45 | 961.12 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT | 15.51 | 0.00 | 01-JAN-00:15 | 2479.44 | 31-AUG-13:30 |
EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F3 SW APARTMENT | 21.41 | 0.01 | 16-SEP-03:30 | 3573.58 | 30-SEP-16:15 |
Heating:EnergyTransfer:Zone:F3 SW APARTMENT | 3.53 | 0.00 | 01-JAN-13:15 | 2054.99 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT | 17.89 | 0.00 | 01-JAN-00:15 | 3573.58 | 30-SEP-16:15 |
EnergyTransfer:Zone:F3 NW APARTMENT | 18.06 | 0.05 | 27-OCT-01:45 | 3254.70 | 08-JUL-19:15 |
Heating:EnergyTransfer:Zone:F3 NW APARTMENT | 6.84 | 0.00 | 20-JAN-19:00 | 2311.71 | 28-DEC-10:00 |
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT | 11.22 | 0.00 | 01-JAN-00:15 | 3254.70 | 08-JUL-19:15 |
EnergyTransfer:Zone:F3 SE APARTMENT | 21.88 | 0.02 | 23-MAR-17:45 | 3254.40 | 28-SEP-14:15 |
Heating:EnergyTransfer:Zone:F3 SE APARTMENT | 3.37 | 0.00 | 01-JAN-13:15 | 2049.05 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT | 18.51 | 0.00 | 01-JAN-00:15 | 3254.40 | 28-SEP-14:15 |
EnergyTransfer:Zone:F3 NE APARTMENT | 18.18 | 0.01 | 07-APR-02:45 | 2479.85 | 22-JUN-10:15 |
Heating:EnergyTransfer:Zone:F3 NE APARTMENT | 6.61 | 0.00 | 20-JAN-10:00 | 2178.13 | 04-JAN-05:00 |
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT | 11.57 | 0.00 | 01-JAN-00:15 | 2479.85 | 22-JUN-10:15 |
EnergyTransfer:Zone:F3 N1 APARTMENT | 11.38 | 0.02 | 16-MAY-15:00 | 1761.85 | 01-JUL-19:45 |
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT | 2.27 | 0.00 | 01-JAN-18:15 | 1742.10 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT | 9.10 | 0.00 | 01-JAN-00:15 | 1761.85 | 01-JUL-19:45 |
EnergyTransfer:Zone:F3 N2 APARTMENT | 11.39 | 0.00 | 05-JUN-20:00 | 1745.05 | 01-JUL-19:45 |
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT | 2.28 | 0.00 | 01-JAN-18:15 | 1739.67 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT | 9.12 | 0.00 | 01-JAN-00:15 | 1745.05 | 01-JUL-19:45 |
EnergyTransfer:Zone:F3 S1 APARTMENT | 17.61 | 0.01 | 26-AUG-11:15 | 2524.00 | 05-OCT-13:00 |
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT | 0.78 | 0.00 | 01-JAN-02:45 | 1026.09 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT | 16.83 | 0.00 | 01-JAN-00:15 | 2524.00 | 05-OCT-13:00 |
EnergyTransfer:Zone:F3 S2 APARTMENT | 17.67 | 0.10 | 06-MAR-08:15 | 2536.02 | 05-OCT-13:00 |
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT | 0.78 | 0.00 | 01-JAN-09:30 | 1024.83 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT | 16.89 | 0.00 | 01-JAN-00:15 | 2536.02 | 05-OCT-13:00 |
EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F4 SW APARTMENT | 21.68 | 0.00 | 03-SEP-03:15 | 3573.61 | 30-SEP-16:30 |
Heating:EnergyTransfer:Zone:F4 SW APARTMENT | 3.79 | 0.00 | 01-JAN-13:15 | 2201.17 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT | 17.89 | 0.00 | 01-JAN-00:15 | 3573.61 | 30-SEP-16:30 |
EnergyTransfer:Zone:F4 NW APARTMENT | 18.54 | 0.01 | 26-MAR-13:15 | 3292.67 | 08-JUL-19:15 |
Heating:EnergyTransfer:Zone:F4 NW APARTMENT | 7.23 | 0.00 | 20-JAN-19:00 | 2490.98 | 28-DEC-10:00 |
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT | 11.31 | 0.00 | 01-JAN-00:15 | 3292.67 | 08-JUL-19:15 |
EnergyTransfer:Zone:F4 SE APARTMENT | 22.05 | 0.05 | 16-OCT-00:30 | 3257.90 | 28-SEP-14:15 |
Heating:EnergyTransfer:Zone:F4 SE APARTMENT | 3.72 | 0.00 | 01-JAN-13:15 | 2205.01 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT | 18.33 | 0.00 | 01-JAN-00:15 | 3257.90 | 28-SEP-14:15 |
EnergyTransfer:Zone:F4 NE APARTMENT | 18.66 | 0.04 | 30-OCT-19:00 | 2509.87 | 01-JUL-19:45 |
Heating:EnergyTransfer:Zone:F4 NE APARTMENT | 6.99 | 0.00 | 20-JAN-10:00 | 2321.00 | 04-JAN-05:00 |
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT | 11.67 | 0.00 | 01-JAN-00:15 | 2509.87 | 01-JUL-19:45 |
EnergyTransfer:Zone:F4 N1 APARTMENT | 11.69 | 0.02 | 23-APR-15:30 | 1964.95 | 03-MAR-13:45 |
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT | 2.41 | 0.00 | 01-JAN-18:15 | 1964.95 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT | 9.29 | 0.00 | 01-JAN-00:15 | 1781.00 | 08-JUL-19:30 |
EnergyTransfer:Zone:F4 N2 APARTMENT | 11.71 | 0.02 | 30-SEP-09:45 | 1961.19 | 03-MAR-13:45 |
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT | 2.41 | 0.00 | 01-JAN-18:15 | 1961.19 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT | 9.30 | 0.00 | 01-JAN-00:15 | 1764.28 | 08-JUL-19:30 |
EnergyTransfer:Zone:F4 S1 APARTMENT | 17.90 | 0.06 | 18-JAN-13:30 | 2541.79 | 05-OCT-13:00 |
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT | 0.85 | 0.00 | 01-JAN-02:45 | 1103.13 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT | 17.06 | 0.00 | 01-JAN-00:15 | 2541.79 | 05-OCT-13:00 |
EnergyTransfer:Zone:F4 S2 APARTMENT | 17.94 | 0.20 | 18-JAN-12:00 | 2551.93 | 05-OCT-13:00 |
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT | 0.85 | 0.00 | 01-JAN-02:45 | 1102.83 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT | 17.09 | 0.00 | 01-JAN-00:15 | 2551.93 | 05-OCT-13:00 |
EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M SW APARTMENT | 21.94 | 0.01 | 04-APR-16:00 | 3613.43 | 05-AUG-16:45 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 4.04 | 0.00 | 01-JAN-13:15 | 2313.72 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 17.90 | 0.00 | 01-JAN-00:15 | 3613.43 | 05-AUG-16:45 |
EnergyTransfer:Zone:M NW APARTMENT | 18.96 | 0.01 | 29-OCT-04:45 | 3342.57 | 08-JUL-19:15 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 7.52 | 0.00 | 18-JAN-15:00 | 2628.97 | 28-DEC-10:00 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 11.44 | 0.00 | 01-JAN-00:15 | 3342.57 | 08-JUL-19:15 |
EnergyTransfer:Zone:M SE APARTMENT | 22.27 | 0.02 | 03-APR-19:15 | 3297.21 | 28-SEP-14:15 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 3.97 | 0.00 | 01-JAN-13:15 | 2319.55 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 18.30 | 0.00 | 01-JAN-00:15 | 3297.21 | 28-SEP-14:15 |
EnergyTransfer:Zone:M NE APARTMENT | 19.06 | 0.03 | 12-MAY-14:15 | 2578.50 | 01-JUL-19:45 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 7.27 | 0.00 | 18-JAN-15:00 | 2467.06 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 11.79 | 0.00 | 01-JAN-00:15 | 2578.50 | 01-JUL-19:45 |
EnergyTransfer:Zone:M N1 APARTMENT | 11.98 | 0.01 | 13-MAY-14:45 | 2149.60 | 03-MAR-13:45 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 2.49 | 0.00 | 01-JAN-18:15 | 2149.60 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 9.49 | 0.00 | 01-JAN-00:15 | 1826.31 | 08-JUL-19:30 |
EnergyTransfer:Zone:M N2 APARTMENT | 12.00 | 0.07 | 24-JUL-08:15 | 2145.69 | 03-MAR-13:45 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 2.49 | 0.00 | 01-JAN-18:15 | 2145.69 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 9.51 | 0.00 | 01-JAN-00:15 | 1809.63 | 08-JUL-19:30 |
EnergyTransfer:Zone:M S1 APARTMENT | 18.11 | 0.11 | 15-OCT-13:15 | 2573.22 | 05-OCT-13:00 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.91 | 0.00 | 01-JAN-02:45 | 1161.70 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 17.20 | 0.00 | 01-JAN-00:15 | 2573.22 | 05-OCT-13:00 |
EnergyTransfer:Zone:M S2 APARTMENT | 18.13 | 0.03 | 02-JAN-12:00 | 2583.08 | 05-OCT-13:00 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.91 | 0.00 | 01-JAN-02:45 | 1161.59 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 17.22 | 0.00 | 01-JAN-00:15 | 2583.08 | 05-OCT-13:00 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F6 SW APARTMENT | 21.65 | 0.01 | 08-NOV-03:15 | 3589.57 | 05-AUG-17:00 |
Heating:EnergyTransfer:Zone:F6 SW APARTMENT | 4.61 | 0.00 | 01-JAN-13:15 | 2462.14 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT | 17.04 | 0.00 | 01-JAN-00:15 | 3589.57 | 05-AUG-17:00 |
EnergyTransfer:Zone:F6 NW APARTMENT | 19.26 | 0.01 | 18-MAY-23:00 | 3325.47 | 08-JUL-19:15 |
Heating:EnergyTransfer:Zone:F6 NW APARTMENT | 8.35 | 0.00 | 20-JAN-19:00 | 2799.03 | 28-DEC-10:00 |
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT | 10.91 | 0.00 | 01-JAN-00:15 | 3325.47 | 08-JUL-19:15 |
EnergyTransfer:Zone:F6 SE APARTMENT | 21.95 | 0.03 | 22-OCT-20:45 | 3276.68 | 06-AUG-14:00 |
Heating:EnergyTransfer:Zone:F6 SE APARTMENT | 4.54 | 0.00 | 01-JAN-13:15 | 2468.67 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT | 17.41 | 0.00 | 01-JAN-00:15 | 3276.68 | 06-AUG-14:00 |
EnergyTransfer:Zone:F6 NE APARTMENT | 19.30 | 0.01 | 28-OCT-22:45 | 2713.21 | 03-MAR-13:45 |
Heating:EnergyTransfer:Zone:F6 NE APARTMENT | 8.06 | 0.00 | 20-JAN-10:00 | 2713.21 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT | 11.24 | 0.00 | 01-JAN-00:15 | 2581.26 | 01-JUL-19:45 |
EnergyTransfer:Zone:F6 N1 APARTMENT | 11.89 | 0.01 | 05-JUN-20:45 | 2399.37 | 03-MAR-13:45 |
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT | 2.94 | 0.00 | 03-JAN-17:15 | 2399.37 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT | 8.95 | 0.00 | 01-JAN-00:15 | 1799.29 | 08-JUL-19:30 |
EnergyTransfer:Zone:F6 N2 APARTMENT | 11.90 | 0.03 | 16-NOV-15:00 | 2395.66 | 03-MAR-13:45 |
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT | 2.94 | 0.00 | 03-JAN-17:15 | 2395.66 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT | 8.96 | 0.00 | 01-JAN-00:15 | 1782.29 | 08-JUL-19:30 |
EnergyTransfer:Zone:F6 S1 APARTMENT | 17.44 | 0.02 | 28-JAN-21:30 | 2542.51 | 05-OCT-13:15 |
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT | 1.12 | 0.00 | 01-JAN-09:45 | 1261.38 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT | 16.32 | 0.00 | 01-JAN-00:15 | 2542.51 | 05-OCT-13:15 |
EnergyTransfer:Zone:F6 S2 APARTMENT | 17.45 | 0.01 | 09-MAR-15:15 | 2553.65 | 05-OCT-13:00 |
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT | 1.12 | 0.00 | 01-JAN-03:00 | 1261.32 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT | 16.33 | 0.00 | 01-JAN-00:15 | 2553.65 | 05-OCT-13:00 |
EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F7 SW APARTMENT | 21.59 | 0.01 | 20-APR-11:15 | 3588.88 | 05-AUG-17:00 |
Heating:EnergyTransfer:Zone:F7 SW APARTMENT | 5.09 | 0.00 | 01-JAN-13:15 | 2581.11 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT | 16.50 | 0.00 | 01-JAN-00:15 | 3588.88 | 05-AUG-17:00 |
EnergyTransfer:Zone:F7 NW APARTMENT | 19.61 | 0.00 | 15-OCT-04:45 | 3328.24 | 08-JUL-19:15 |
Heating:EnergyTransfer:Zone:F7 NW APARTMENT | 8.99 | 0.00 | 20-JAN-19:00 | 2936.35 | 28-DEC-10:00 |
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT | 10.62 | 0.00 | 01-JAN-00:15 | 3328.24 | 08-JUL-19:15 |
EnergyTransfer:Zone:F7 SE APARTMENT | 21.87 | 0.01 | 11-MAY-20:30 | 3281.23 | 06-AUG-14:00 |
Heating:EnergyTransfer:Zone:F7 SE APARTMENT | 5.01 | 0.00 | 01-JAN-13:30 | 2588.11 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT | 16.86 | 0.00 | 01-JAN-00:15 | 3281.23 | 06-AUG-14:00 |
EnergyTransfer:Zone:F7 NE APARTMENT | 19.60 | 0.02 | 13-JUN-11:00 | 2917.53 | 03-MAR-13:45 |
Heating:EnergyTransfer:Zone:F7 NE APARTMENT | 8.67 | 0.00 | 20-JAN-10:00 | 2917.53 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT | 10.93 | 0.00 | 01-JAN-00:15 | 2593.76 | 01-JUL-19:45 |
EnergyTransfer:Zone:F7 N1 APARTMENT | 11.93 | 0.00 | 12-SEP-15:15 | 2610.88 | 03-MAR-13:45 |
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT | 3.28 | 0.00 | 03-JAN-17:15 | 2610.88 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT | 8.65 | 0.00 | 01-JAN-00:15 | 1792.49 | 08-JUL-19:30 |
EnergyTransfer:Zone:F7 N2 APARTMENT | 11.94 | 0.01 | 01-MAR-11:45 | 2606.94 | 03-MAR-13:45 |
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT | 3.28 | 0.00 | 03-JAN-17:15 | 2606.94 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT | 8.66 | 0.00 | 01-JAN-00:15 | 1775.60 | 08-JUL-19:30 |
EnergyTransfer:Zone:F7 S1 APARTMENT | 17.04 | 0.02 | 22-NOV-21:30 | 2533.83 | 05-OCT-13:15 |
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT | 1.30 | 0.00 | 01-JAN-03:00 | 1370.84 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT | 15.75 | 0.00 | 01-JAN-00:15 | 2533.83 | 05-OCT-13:15 |
EnergyTransfer:Zone:F7 S2 APARTMENT | 17.07 | 0.05 | 20-FEB-04:30 | 2543.59 | 05-OCT-13:15 |
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT | 1.30 | 0.00 | 01-JAN-03:00 | 1361.68 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT | 15.77 | 0.00 | 01-JAN-00:15 | 2543.59 | 05-OCT-13:15 |
EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F8 SW APARTMENT | 21.66 | 0.00 | 12-JUN-06:45 | 3599.18 | 05-AUG-17:15 |
Heating:EnergyTransfer:Zone:F8 SW APARTMENT | 5.59 | 0.00 | 01-JAN-13:30 | 2694.08 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT | 16.08 | 0.00 | 01-JAN-00:15 | 3599.18 | 05-AUG-17:15 |
EnergyTransfer:Zone:F8 NW APARTMENT | 20.05 | 0.01 | 10-MAY-03:30 | 3340.15 | 08-JUL-19:15 |
Heating:EnergyTransfer:Zone:F8 NW APARTMENT | 9.62 | 0.00 | 20-JAN-19:00 | 3074.16 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT | 10.44 | 0.00 | 01-JAN-00:15 | 3340.15 | 08-JUL-19:15 |
EnergyTransfer:Zone:F8 SE APARTMENT | 21.92 | 0.01 | 06-NOV-16:45 | 3296.21 | 06-AUG-14:00 |
Heating:EnergyTransfer:Zone:F8 SE APARTMENT | 5.49 | 0.00 | 01-JAN-13:30 | 2701.48 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT | 16.43 | 0.00 | 01-JAN-00:15 | 3296.21 | 06-AUG-14:00 |
EnergyTransfer:Zone:F8 NE APARTMENT | 20.00 | 0.01 | 25-OCT-18:00 | 3101.99 | 03-MAR-13:45 |
Heating:EnergyTransfer:Zone:F8 NE APARTMENT | 9.27 | 0.00 | 20-JAN-10:00 | 3101.99 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT | 10.73 | 0.00 | 01-JAN-00:15 | 2601.81 | 01-JUL-19:45 |
EnergyTransfer:Zone:F8 N1 APARTMENT | 12.10 | 0.17 | 10-FEB-00:30 | 2800.54 | 03-MAR-13:45 |
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT | 3.64 | 0.00 | 03-JAN-17:15 | 2800.54 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT | 8.46 | 0.00 | 01-JAN-00:15 | 1799.88 | 08-JUL-19:30 |
EnergyTransfer:Zone:F8 N2 APARTMENT | 12.11 | 0.01 | 04-MAR-12:15 | 2797.15 | 03-MAR-13:45 |
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT | 3.64 | 0.00 | 03-JAN-17:15 | 2797.15 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT | 8.47 | 0.00 | 01-JAN-00:15 | 1783.13 | 08-JUL-19:30 |
EnergyTransfer:Zone:F8 S1 APARTMENT | 16.78 | 0.03 | 13-MAR-05:15 | 2522.82 | 31-AUG-13:45 |
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT | 1.50 | 0.00 | 01-JAN-03:00 | 1533.37 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT | 15.28 | 0.00 | 01-JAN-00:15 | 2522.82 | 31-AUG-13:45 |
EnergyTransfer:Zone:F8 S2 APARTMENT | 16.81 | 0.03 | 09-MAR-13:30 | 2533.45 | 31-AUG-13:45 |
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT | 1.51 | 0.00 | 01-JAN-03:00 | 1529.13 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT | 15.30 | 0.00 | 01-JAN-00:15 | 2533.45 | 31-AUG-13:45 |
EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F9 SW APARTMENT | 22.34 | 0.01 | 23-MAR-19:45 | 3721.00 | 05-AUG-17:15 |
Heating:EnergyTransfer:Zone:F9 SW APARTMENT | 6.61 | 0.00 | 01-JAN-13:30 | 2880.86 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT | 15.73 | 0.00 | 01-JAN-00:15 | 3721.00 | 05-AUG-17:15 |
EnergyTransfer:Zone:F9 NW APARTMENT | 21.36 | 0.01 | 16-SEP-04:00 | 3436.72 | 08-JUL-19:15 |
Heating:EnergyTransfer:Zone:F9 NW APARTMENT | 10.90 | 0.00 | 26-JAN-16:30 | 3274.66 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT | 10.47 | 0.00 | 01-JAN-00:15 | 3436.72 | 08-JUL-19:15 |
EnergyTransfer:Zone:F9 SE APARTMENT | 22.49 | 0.01 | 08-APR-18:15 | 3381.12 | 06-AUG-14:00 |
Heating:EnergyTransfer:Zone:F9 SE APARTMENT | 6.45 | 0.00 | 01-JAN-13:30 | 2888.93 | 28-DEC-08:15 |
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT | 16.04 | 0.00 | 01-JAN-00:15 | 3381.12 | 06-AUG-14:00 |
EnergyTransfer:Zone:F9 NE APARTMENT | 21.15 | 0.03 | 30-MAY-17:00 | 3301.20 | 03-MAR-13:45 |
Heating:EnergyTransfer:Zone:F9 NE APARTMENT | 10.45 | 0.00 | 20-JAN-19:00 | 3301.20 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT | 10.70 | 0.00 | 01-JAN-00:15 | 2651.39 | 01-JUL-19:45 |
EnergyTransfer:Zone:F9 N1 APARTMENT | 12.86 | 0.05 | 21-DEC-20:45 | 3010.43 | 03-MAR-13:45 |
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT | 4.50 | 0.00 | 03-JAN-17:30 | 3010.43 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT | 8.36 | 0.00 | 01-JAN-00:15 | 1899.28 | 08-JUL-19:30 |
EnergyTransfer:Zone:F9 N2 APARTMENT | 12.88 | 0.02 | 26-AUG-14:45 | 3007.59 | 03-MAR-13:45 |
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT | 4.51 | 0.00 | 03-JAN-17:30 | 3007.59 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT | 8.38 | 0.00 | 01-JAN-00:15 | 1882.59 | 08-JUL-19:15 |
EnergyTransfer:Zone:F9 S1 APARTMENT | 16.71 | 0.04 | 05-FEB-06:00 | 2583.42 | 31-AUG-14:00 |
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT | 1.99 | 0.00 | 01-JAN-10:00 | 1735.14 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT | 14.72 | 0.00 | 01-JAN-00:15 | 2583.42 | 31-AUG-14:00 |
EnergyTransfer:Zone:F9 S2 APARTMENT | 16.74 | 0.12 | 16-NOV-03:30 | 2594.80 | 31-AUG-14:00 |
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT | 2.00 | 0.00 | 01-JAN-10:00 | 1731.09 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT | 14.74 | 0.00 | 01-JAN-00:15 | 2594.80 | 31-AUG-14:00 |
EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:T SW APARTMENT | 29.21 | 0.01 | 14-MAR-14:00 | 4637.45 | 05-AUG-16:45 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 12.52 | 0.00 | 01-JAN-13:30 | 3591.53 | 04-JAN-05:00 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 16.69 | 0.00 | 01-JAN-00:15 | 4637.45 | 05-AUG-16:45 |
EnergyTransfer:Zone:T NW APARTMENT | 27.91 | 0.13 | 06-FEB-18:45 | 4213.87 | 12-JUL-17:45 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 16.36 | 0.00 | 26-JAN-16:15 | 3743.19 | 28-DEC-10:00 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 11.55 | 0.00 | 01-JAN-00:15 | 4213.87 | 12-JUL-17:45 |
EnergyTransfer:Zone:T SE APARTMENT | 28.62 | 0.01 | 14-OCT-20:00 | 4129.23 | 01-OCT-12:45 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 12.09 | 0.00 | 01-JAN-13:30 | 3598.70 | 04-JAN-05:00 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 16.52 | 0.00 | 01-JAN-00:15 | 4129.23 | 01-OCT-12:45 |
EnergyTransfer:Zone:T NE APARTMENT | 26.80 | 0.03 | 24-SEP-05:00 | 3659.05 | 04-JAN-05:00 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 15.53 | 0.00 | 24-JAN-10:45 | 3659.05 | 04-JAN-05:00 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 11.27 | 0.00 | 01-JAN-00:15 | 3272.15 | 12-JUL-17:15 |
EnergyTransfer:Zone:T N1 APARTMENT | 17.25 | 0.00 | 10-MAR-21:30 | 3074.49 | 03-MAR-13:45 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 8.67 | 0.00 | 09-JAN-13:45 | 3074.49 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 8.59 | 0.00 | 01-JAN-00:15 | 2530.51 | 01-JUL-19:45 |
EnergyTransfer:Zone:T N2 APARTMENT | 17.26 | 0.01 | 03-SEP-23:45 | 3072.48 | 03-MAR-13:45 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 8.67 | 0.00 | 09-JAN-13:45 | 3072.48 | 03-MAR-13:45 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 8.59 | 0.00 | 01-JAN-00:15 | 2506.32 | 01-JUL-19:45 |
EnergyTransfer:Zone:T S1 APARTMENT | 19.79 | 0.02 | 01-NOV-18:00 | 3425.70 | 28-SEP-14:15 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 5.69 | 0.00 | 01-JAN-13:00 | 2249.42 | 04-JAN-05:00 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 14.10 | 0.00 | 01-JAN-00:15 | 3425.70 | 28-SEP-14:15 |
EnergyTransfer:Zone:T S2 APARTMENT | 19.82 | 0.01 | 03-DEC-14:30 | 3433.42 | 28-SEP-14:15 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 5.69 | 0.00 | 01-JAN-13:00 | 2249.18 | 04-JAN-05:00 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 14.13 | 0.00 | 01-JAN-00:15 | 3433.42 | 28-SEP-14:15 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Plant | 1313.59 | 461.65 | 19-AUG-01:15 | 198631.23 | 28-DEC-08:15 |
WaterSystems:EnergyTransfer | 906.74 | 461.65 | 19-AUG-01:15 | 62516.78 | 14-FEB-07:30 |
sub cat:WaterSystems:EnergyTransfer | 906.74 | 461.65 | 19-AUG-01:15 | 62516.78 | 14-FEB-07:30 |
EnergyTransfer:HVAC | 1656.46 | 0.00 | 03-MAR-18:45 | 251657.34 | 31-JUL-18:00 |
CoolingCoils:EnergyTransfer | 1069.56 | 0.00 | 01-JAN-00:15 | 251657.34 | 31-JUL-18:00 |
HeatingCoils:EnergyTransfer | 586.90 | 0.00 | 10-FEB-15:00 | 192816.02 | 04-JAN-05:00 |
PlantLoopHeatingDemand:HVAC | 449.02 | 0.00 | 10-FEB-15:00 | 147871.06 | 04-JAN-05:00 |
HeatingCoils:PlantLoopHeatingDemand | 449.02 | 0.00 | 10-FEB-15:00 | 147871.06 | 04-JAN-05:00 |
Boilers:EnergyTransfer | 406.85 | 0.00 | 26-JAN-13:45 | 144930.60 | 04-JAN-05:15 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:31
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 5.096 | -10.277 | 0.000 | 0.000 | 3.815 | 1.087 | 12.213 | 23.280 | 0.000 | 0.304 | 0.000 | 0.000 | -11.272 | 0.000 | -7.374 | -16.871 |
G NW APARTMENT | 8.076 | -6.689 | 0.000 | 0.000 | 3.857 | 1.087 | 12.213 | 11.723 | 0.000 | 0.305 | 0.000 | 0.000 | -11.430 | 0.000 | -6.925 | -12.215 |
OFFICE | 3.729 | -19.780 | 0.000 | 0.000 | 0.518 | 29.882 | 9.495 | 23.198 | 0.000 | 0.233 | 0.000 | 0.000 | -11.141 | 0.000 | -4.732 | -31.403 |
G NE APARTMENT | 7.762 | -6.811 | 0.000 | 0.000 | 3.873 | 1.087 | 12.213 | 11.691 | 0.000 | 0.305 | 0.000 | 0.000 | -11.035 | 0.000 | -6.938 | -12.147 |
G N1 APARTMENT | 4.182 | -5.166 | 0.000 | 0.000 | 3.880 | 1.087 | 12.213 | 3.809 | 0.000 | 0.213 | 0.000 | 0.000 | -7.062 | 0.000 | -4.848 | -8.308 |
G N2 APARTMENT | 4.179 | -5.176 | 0.000 | 0.000 | 3.881 | 1.087 | 12.213 | 3.806 | 0.000 | 0.213 | 0.000 | 0.000 | -7.058 | 0.000 | -4.850 | -8.294 |
G S1 APARTMENT | 1.801 | -9.214 | 0.000 | 0.000 | 3.817 | 1.087 | 12.213 | 15.470 | 0.000 | 0.211 | 0.000 | 0.000 | -6.855 | 0.000 | -5.389 | -13.140 |
G S2 APARTMENT | 1.705 | -9.473 | 0.000 | 0.000 | 3.812 | 1.087 | 12.213 | 15.449 | 0.000 | 0.211 | 0.000 | 0.000 | -6.871 | 0.000 | -5.434 | -12.697 |
F2 SW APARTMENT | 3.596 | -16.890 | 0.000 | 0.000 | 3.741 | 1.087 | 12.213 | 22.642 | 0.000 | 0.415 | 0.000 | 0.000 | -12.039 | 0.000 | -10.098 | -4.666 |
F2 NW APARTMENT | 6.889 | -10.527 | 0.000 | 0.000 | 3.805 | 1.087 | 12.213 | 11.263 | 0.000 | 0.415 | 0.000 | 0.000 | -12.092 | 0.000 | -9.563 | -3.490 |
F2 SE APARTMENT | 3.043 | -18.706 | 0.000 | 0.000 | 3.733 | 1.087 | 12.213 | 22.598 | 0.000 | 0.417 | 0.000 | 0.000 | -11.795 | 0.000 | -10.206 | -2.383 |
F2 NE APARTMENT | 6.621 | -10.838 | 0.000 | 0.000 | 3.820 | 1.087 | 12.213 | 11.245 | 0.000 | 0.416 | 0.000 | 0.000 | -11.671 | 0.000 | -9.558 | -3.333 |
F2 N1 APARTMENT | 2.480 | -8.269 | 0.000 | 0.000 | 3.822 | 1.087 | 12.213 | 3.567 | 0.000 | 0.282 | 0.000 | 0.000 | -7.527 | 0.000 | -6.662 | -0.993 |
F2 N2 APARTMENT | 2.482 | -8.287 | 0.000 | 0.000 | 3.823 | 1.087 | 12.213 | 3.565 | 0.000 | 0.282 | 0.000 | 0.000 | -7.523 | 0.000 | -6.663 | -0.978 |
F2 S1 APARTMENT | 0.870 | -15.351 | 0.000 | 0.000 | 3.727 | 1.087 | 12.213 | 15.070 | 0.000 | 0.280 | 0.001 | 0.000 | -7.344 | 0.000 | -7.327 | -3.223 |
F2 S2 APARTMENT | 0.854 | -15.506 | 0.000 | 0.000 | 3.724 | 1.087 | 12.213 | 15.063 | 0.000 | 0.280 | 0.000 | 0.000 | -7.351 | 0.000 | -7.341 | -3.022 |
F3 SW APARTMENT | 3.526 | -17.889 | 0.000 | 0.000 | 3.732 | 1.087 | 12.213 | 22.403 | 0.000 | 0.503 | 0.001 | 0.000 | -12.249 | 0.000 | -11.574 | -1.751 |
F3 NW APARTMENT | 6.841 | -11.222 | 0.000 | 0.000 | 3.795 | 1.087 | 12.213 | 11.103 | 0.000 | 0.504 | 0.000 | 0.000 | -12.301 | 0.000 | -11.008 | -1.011 |
F3 SE APARTMENT | 3.370 | -18.510 | 0.000 | 0.000 | 3.736 | 1.087 | 12.213 | 22.425 | 0.000 | 0.506 | 0.000 | 0.000 | -11.912 | 0.000 | -11.613 | -1.300 |
F3 NE APARTMENT | 6.608 | -11.568 | 0.000 | 0.000 | 3.810 | 1.087 | 12.213 | 11.097 | 0.000 | 0.505 | 0.000 | 0.000 | -11.876 | 0.000 | -11.000 | -0.874 |
F3 N1 APARTMENT | 2.275 | -9.104 | 0.000 | 0.000 | 3.806 | 1.087 | 12.213 | 3.494 | 0.000 | 0.347 | 1.208 | 0.000 | -7.680 | 0.000 | -7.645 | -0.000 |
F3 N2 APARTMENT | 2.276 | -9.116 | 0.000 | 0.000 | 3.807 | 1.087 | 12.213 | 3.492 | 0.000 | 0.347 | 1.218 | 0.000 | -7.677 | 0.000 | -7.645 | -0.000 |
F3 S1 APARTMENT | 0.780 | -16.828 | 0.000 | 0.000 | 3.708 | 1.087 | 12.213 | 14.915 | 0.000 | 0.344 | 0.000 | 0.000 | -7.499 | 0.000 | -8.334 | -0.385 |
F3 S2 APARTMENT | 0.780 | -16.886 | 0.000 | 0.000 | 3.707 | 1.087 | 12.213 | 14.911 | 0.000 | 0.345 | 0.001 | 0.000 | -7.500 | 0.000 | -8.340 | -0.316 |
F4 SW APARTMENT | 3.792 | -17.891 | 0.000 | 0.000 | 3.732 | 1.087 | 12.213 | 22.265 | 0.000 | 0.553 | 0.001 | 0.000 | -12.341 | 0.000 | -12.528 | -0.882 |
F4 NW APARTMENT | 7.230 | -11.307 | 0.000 | 0.000 | 3.794 | 1.087 | 12.213 | 11.017 | 0.000 | 0.554 | 0.000 | 0.000 | -12.404 | 0.000 | -11.945 | -0.239 |
F4 SE APARTMENT | 3.719 | -18.327 | 0.000 | 0.000 | 3.739 | 1.087 | 12.213 | 22.305 | 0.000 | 0.556 | 0.000 | 0.000 | -11.986 | 0.000 | -12.553 | -0.752 |
F4 NE APARTMENT | 6.993 | -11.667 | 0.000 | 0.000 | 3.809 | 1.087 | 12.213 | 11.020 | 0.000 | 0.554 | 0.000 | 0.000 | -11.977 | 0.000 | -11.933 | -0.098 |
F4 N1 APARTMENT | 2.406 | -9.288 | 0.000 | 0.000 | 3.802 | 1.087 | 12.213 | 3.459 | 0.000 | 0.379 | 1.932 | 0.000 | -7.757 | 0.000 | -8.231 | -0.000 |
F4 N2 APARTMENT | 2.409 | -9.303 | 0.000 | 0.000 | 3.802 | 1.087 | 12.213 | 3.457 | 0.000 | 0.379 | 1.941 | 0.000 | -7.753 | 0.000 | -8.231 | -0.000 |
F4 S1 APARTMENT | 0.846 | -17.058 | 0.000 | 0.000 | 3.705 | 1.087 | 12.213 | 14.826 | 0.000 | 0.377 | 0.499 | 0.000 | -7.567 | 0.000 | -8.927 | -0.000 |
F4 S2 APARTMENT | 0.850 | -17.086 | 0.000 | 0.000 | 3.705 | 1.087 | 12.213 | 14.824 | 0.000 | 0.377 | 0.528 | 0.000 | -7.566 | 0.000 | -8.931 | -0.000 |
M SW APARTMENT | 4.037 | -17.901 | 0.000 | 0.000 | 3.734 | 1.087 | 12.213 | 22.156 | 0.000 | 0.593 | 0.001 | 0.000 | -12.414 | 0.000 | -13.428 | -0.075 |
M NW APARTMENT | 7.523 | -11.436 | 0.000 | 0.000 | 3.795 | 1.087 | 12.213 | 10.951 | 0.000 | 0.594 | 0.573 | 0.000 | -12.485 | 0.000 | -12.814 | -0.001 |
M SE APARTMENT | 3.971 | -18.301 | 0.000 | 0.000 | 3.741 | 1.087 | 12.213 | 22.203 | 0.000 | 0.596 | 0.001 | 0.000 | -12.055 | 0.000 | -13.452 | -0.002 |
M NE APARTMENT | 7.270 | -11.794 | 0.000 | 0.000 | 3.809 | 1.087 | 12.213 | 10.960 | 0.000 | 0.594 | 0.718 | 0.000 | -12.057 | 0.000 | -12.799 | -0.000 |
M N1 APARTMENT | 2.488 | -9.492 | 0.000 | 0.000 | 3.800 | 1.087 | 12.213 | 3.433 | 0.000 | 0.404 | 2.684 | 0.000 | -7.816 | 0.000 | -8.801 | -0.000 |
M N2 APARTMENT | 2.492 | -9.506 | 0.000 | 0.000 | 3.801 | 1.087 | 12.213 | 3.432 | 0.000 | 0.404 | 2.692 | 0.000 | -7.812 | 0.000 | -8.802 | -0.000 |
M S1 APARTMENT | 0.909 | -17.201 | 0.000 | 0.000 | 3.706 | 1.087 | 12.213 | 14.758 | 0.000 | 0.402 | 1.270 | 0.000 | -7.618 | 0.000 | -9.525 | -0.000 |
M S2 APARTMENT | 0.913 | -17.221 | 0.000 | 0.000 | 3.706 | 1.087 | 12.213 | 14.756 | 0.000 | 0.402 | 1.289 | 0.000 | -7.616 | 0.000 | -9.529 | -0.000 |
F6 SW APARTMENT | 4.611 | -17.037 | 0.000 | 0.000 | 3.743 | 1.087 | 12.213 | 22.101 | 0.000 | 0.626 | 0.000 | 0.000 | -12.413 | 0.000 | -14.155 | -0.776 |
F6 NW APARTMENT | 8.351 | -10.907 | 0.000 | 0.000 | 3.803 | 1.087 | 12.213 | 10.931 | 0.000 | 0.627 | 0.000 | 0.000 | -12.489 | 0.000 | -13.493 | -0.123 |
F6 SE APARTMENT | 4.537 | -17.411 | 0.000 | 0.000 | 3.750 | 1.087 | 12.213 | 22.154 | 0.000 | 0.630 | 0.001 | 0.000 | -12.055 | 0.000 | -14.184 | -0.720 |
F6 NE APARTMENT | 8.060 | -11.243 | 0.000 | 0.000 | 3.818 | 1.087 | 12.213 | 10.946 | 0.000 | 0.627 | 0.028 | 0.000 | -12.061 | 0.000 | -13.475 | -0.000 |
F6 N1 APARTMENT | 2.936 | -8.951 | 0.000 | 0.000 | 3.809 | 1.087 | 12.213 | 3.434 | 0.000 | 0.425 | 2.077 | 0.000 | -7.817 | 0.000 | -9.213 | -0.000 |
F6 N2 APARTMENT | 2.935 | -8.963 | 0.000 | 0.000 | 3.810 | 1.087 | 12.213 | 3.432 | 0.000 | 0.425 | 2.087 | 0.000 | -7.813 | 0.000 | -9.214 | -0.000 |
F6 S1 APARTMENT | 1.117 | -16.319 | 0.000 | 0.000 | 3.715 | 1.087 | 12.213 | 14.725 | 0.000 | 0.424 | 0.646 | 0.000 | -7.617 | 0.000 | -9.991 | -0.000 |
F6 S2 APARTMENT | 1.120 | -16.334 | 0.000 | 0.000 | 3.715 | 1.087 | 12.213 | 14.722 | 0.000 | 0.424 | 0.663 | 0.000 | -7.615 | 0.000 | -9.994 | -0.000 |
F7 SW APARTMENT | 5.093 | -16.497 | 0.000 | 0.000 | 3.749 | 1.087 | 12.213 | 22.048 | 0.000 | 0.655 | 0.001 | 0.000 | -12.424 | 0.000 | -14.798 | -1.125 |
F7 NW APARTMENT | 8.988 | -10.619 | 0.000 | 0.000 | 3.810 | 1.087 | 12.213 | 10.908 | 0.000 | 0.656 | 0.000 | 0.000 | -12.503 | 0.000 | -14.098 | -0.441 |
F7 SE APARTMENT | 5.009 | -16.861 | 0.000 | 0.000 | 3.756 | 1.087 | 12.213 | 22.104 | 0.000 | 0.659 | 0.000 | 0.000 | -12.065 | 0.000 | -14.831 | -1.070 |
F7 NE APARTMENT | 8.667 | -10.932 | 0.000 | 0.000 | 3.824 | 1.087 | 12.213 | 10.928 | 0.000 | 0.656 | 0.000 | 0.000 | -12.075 | 0.000 | -14.078 | -0.289 |
F7 N1 APARTMENT | 3.276 | -8.651 | 0.000 | 0.000 | 3.816 | 1.087 | 12.213 | 3.432 | 0.000 | 0.444 | 1.791 | 0.000 | -7.824 | 0.000 | -9.583 | -0.000 |
F7 N2 APARTMENT | 3.276 | -8.663 | 0.000 | 0.000 | 3.817 | 1.087 | 12.213 | 3.430 | 0.000 | 0.443 | 1.802 | 0.000 | -7.821 | 0.000 | -9.583 | -0.001 |
F7 S1 APARTMENT | 1.298 | -15.747 | 0.000 | 0.000 | 3.723 | 1.087 | 12.213 | 14.692 | 0.000 | 0.442 | 0.317 | 0.000 | -7.622 | 0.000 | -10.402 | -0.001 |
F7 S2 APARTMENT | 1.304 | -15.766 | 0.000 | 0.000 | 3.723 | 1.087 | 12.213 | 14.690 | 0.000 | 0.443 | 0.335 | 0.000 | -7.620 | 0.000 | -10.406 | -0.000 |
F8 SW APARTMENT | 5.587 | -16.076 | 0.000 | 0.000 | 3.756 | 1.087 | 12.213 | 22.002 | 0.000 | 0.684 | 0.000 | 0.000 | -12.432 | 0.000 | -15.391 | -1.429 |
F8 NW APARTMENT | 9.617 | -10.436 | 0.000 | 0.000 | 3.815 | 1.087 | 12.213 | 10.886 | 0.000 | 0.685 | 0.000 | 0.000 | -12.518 | 0.000 | -14.659 | -0.690 |
F8 SE APARTMENT | 5.487 | -16.428 | 0.000 | 0.000 | 3.762 | 1.087 | 12.213 | 22.061 | 0.000 | 0.688 | 0.000 | 0.000 | -12.074 | 0.000 | -15.426 | -1.370 |
F8 NE APARTMENT | 9.269 | -10.732 | 0.000 | 0.000 | 3.829 | 1.087 | 12.213 | 10.911 | 0.000 | 0.685 | 0.000 | 0.000 | -12.090 | 0.000 | -14.636 | -0.535 |
F8 N1 APARTMENT | 3.639 | -8.458 | 0.000 | 0.000 | 3.822 | 1.087 | 12.213 | 3.429 | 0.000 | 0.464 | 1.568 | 0.000 | -7.832 | 0.000 | -9.931 | -0.000 |
F8 N2 APARTMENT | 3.639 | -8.472 | 0.000 | 0.000 | 3.823 | 1.087 | 12.213 | 3.427 | 0.000 | 0.463 | 1.580 | 0.000 | -7.828 | 0.000 | -9.931 | -0.000 |
F8 S1 APARTMENT | 1.503 | -15.277 | 0.000 | 0.000 | 3.730 | 1.087 | 12.213 | 14.665 | 0.000 | 0.463 | 0.027 | 0.000 | -7.625 | 0.000 | -10.785 | -0.000 |
F8 S2 APARTMENT | 1.509 | -15.297 | 0.000 | 0.000 | 3.730 | 1.087 | 12.213 | 14.662 | 0.000 | 0.463 | 0.046 | 0.000 | -7.623 | 0.000 | -10.789 | -0.001 |
F9 SW APARTMENT | 6.606 | -15.733 | 0.000 | 0.000 | 3.764 | 1.087 | 12.213 | 21.982 | 0.000 | 0.711 | 0.000 | 0.000 | -12.410 | 0.000 | -15.903 | -2.317 |
F9 NW APARTMENT | 10.895 | -10.467 | 0.000 | 0.000 | 3.820 | 1.087 | 12.213 | 10.878 | 0.000 | 0.711 | 0.000 | 0.000 | -12.510 | 0.000 | -15.156 | -1.470 |
F9 SE APARTMENT | 6.451 | -16.041 | 0.000 | 0.000 | 3.770 | 1.087 | 12.213 | 22.044 | 0.000 | 0.715 | 0.000 | 0.000 | -12.053 | 0.000 | -15.945 | -2.240 |
F9 NE APARTMENT | 10.453 | -10.695 | 0.000 | 0.000 | 3.835 | 1.087 | 12.213 | 10.906 | 0.000 | 0.710 | 0.000 | 0.000 | -12.084 | 0.000 | -15.133 | -1.291 |
F9 N1 APARTMENT | 4.503 | -8.359 | 0.000 | 0.000 | 3.828 | 1.087 | 12.213 | 3.431 | 0.000 | 0.482 | 0.880 | 0.000 | -7.823 | 0.000 | -10.240 | -0.000 |
F9 N2 APARTMENT | 4.506 | -8.378 | 0.000 | 0.000 | 3.829 | 1.087 | 12.213 | 3.429 | 0.000 | 0.481 | 0.894 | 0.000 | -7.819 | 0.000 | -10.241 | -0.000 |
F9 S1 APARTMENT | 1.990 | -14.721 | 0.000 | 0.000 | 3.741 | 1.087 | 12.213 | 14.655 | 0.000 | 0.482 | 0.001 | 0.000 | -7.604 | 0.000 | -11.104 | -0.737 |
F9 S2 APARTMENT | 1.996 | -14.743 | 0.000 | 0.000 | 3.741 | 1.087 | 12.213 | 14.652 | 0.000 | 0.482 | 0.000 | 0.000 | -7.603 | 0.000 | -11.110 | -0.714 |
T SW APARTMENT | 12.524 | -16.687 | 0.000 | 0.000 | 3.802 | 1.087 | 12.213 | 21.704 | 0.000 | 0.734 | 0.000 | 0.000 | -11.855 | 0.000 | -16.281 | -7.240 |
T NW APARTMENT | 16.361 | -11.552 | 0.000 | 0.000 | 3.841 | 1.087 | 12.213 | 10.654 | 0.000 | 0.732 | 0.000 | 0.000 | -12.055 | 0.000 | -15.651 | -5.629 |
T SE APARTMENT | 12.094 | -16.522 | 0.000 | 0.000 | 3.809 | 1.087 | 12.213 | 21.801 | 0.000 | 0.736 | 0.000 | 0.000 | -11.540 | 0.000 | -16.341 | -7.336 |
T NE APARTMENT | 15.529 | -11.272 | 0.000 | 0.000 | 3.858 | 1.087 | 12.213 | 10.728 | 0.000 | 0.733 | 0.000 | 0.000 | -11.674 | 0.000 | -15.641 | -5.561 |
T N1 APARTMENT | 8.668 | -8.586 | 0.000 | 0.000 | 3.849 | 1.087 | 12.213 | 3.355 | 0.000 | 0.497 | 0.000 | 0.000 | -7.536 | 0.000 | -10.589 | -2.956 |
T N2 APARTMENT | 8.671 | -8.589 | 0.000 | 0.000 | 3.850 | 1.087 | 12.213 | 3.350 | 0.000 | 0.497 | 0.000 | 0.000 | -7.531 | 0.000 | -10.597 | -2.951 |
T S1 APARTMENT | 5.688 | -14.102 | 0.000 | 0.000 | 3.783 | 1.087 | 12.213 | 14.515 | 0.000 | 0.499 | 0.000 | 0.000 | -7.299 | 0.000 | -11.351 | -5.033 |
T S2 APARTMENT | 5.695 | -14.129 | 0.000 | 0.000 | 3.783 | 1.087 | 12.213 | 14.510 | 0.000 | 0.499 | 0.000 | 0.000 | -7.295 | 0.000 | -11.358 | -5.004 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 5.361 | 0.000 | 2.435 | 33.323 | 0.000 | -2.519 | 0.000 | -55.040 | -0.000 |
F2 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.445 | 0.000 | 0.033 | 0.000 | 0.000 | -1.515 | 0.000 | -1.235 | -16.167 |
F3 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.398 | 0.000 | 0.038 | 0.000 | 0.000 | -1.573 | 0.000 | -1.507 | -15.795 |
F4 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.374 | 0.000 | 0.041 | 0.000 | 0.000 | -1.599 | 0.000 | -1.702 | -15.554 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32.880 | 0.000 | 2.346 | 0.000 | 0.039 | 0.000 | 0.000 | -1.635 | 0.000 | -1.923 | -31.708 |
F6 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.356 | 0.000 | 0.047 | 0.000 | 0.000 | -1.610 | 0.000 | -1.971 | -15.263 |
F7 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.356 | 0.000 | 0.051 | 0.000 | 0.000 | -1.602 | 0.000 | -2.064 | -15.180 |
F8 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.353 | 0.000 | 0.053 | 0.000 | 0.000 | -1.601 | 0.000 | -2.155 | -15.090 |
F9 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.352 | 0.000 | 0.053 | 0.000 | 0.000 | -1.597 | 0.000 | -2.231 | -15.017 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 8.151 | 2.298 | 0.000 | 0.031 | 0.000 | 0.000 | -1.548 | 0.000 | -2.361 | -23.011 |
Total Facility | 391.123 | -1025.518 | 0.000 | 0.000 | 299.478 | 296.560 | 982.450 | 1059.056 | 0.000 | 41.625 | 64.625 | 0.000 | -801.334 | 0.000 | -941.374 | -366.687 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 30-SEP-16:10 | 0.00 | -2834.06 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 4302.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -50.97 | -2156.11 |
G NW APARTMENT | 14-JUL-18:00 | 0.00 | -2518.15 | 0.00 | 0.00 | 139.98 | 87.56 | 588.62 | 3355.88 | 0.00 | 119.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1773.36 |
OFFICE | 28-SEP-14:15 | 0.00 | -3980.64 | 0.00 | 0.00 | 65.20 | 2345.88 | 588.62 | 3629.88 | 0.00 | 20.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2669.81 |
G NE APARTMENT | 22-JUL-08:30 | 0.00 | -1819.84 | 0.00 | 0.00 | 40.75 | 12.97 | 394.37 | 2849.58 | 0.00 | 190.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1667.92 |
G N1 APARTMENT | 08-JUL-19:30 | 0.00 | -1274.35 | 0.00 | 0.00 | 140.79 | 103.77 | 523.87 | 1037.68 | 0.00 | 186.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -718.62 |
G N2 APARTMENT | 08-JUL-19:30 | 0.00 | -1254.04 | 0.00 | 0.00 | 140.80 | 103.77 | 523.87 | 1038.21 | 0.00 | 187.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -739.65 |
G S1 APARTMENT | 31-AUG-13:45 | 0.00 | -1917.68 | 0.00 | 0.00 | 40.72 | 12.97 | 382.60 | 3046.93 | 0.00 | 115.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1680.98 |
G S2 APARTMENT | 31-AUG-13:45 | 0.00 | -1989.26 | 0.00 | 0.00 | 40.74 | 12.97 | 382.60 | 3045.83 | 0.00 | 116.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1609.88 |
F2 SW APARTMENT | 30-SEP-16:10 | 0.00 | -3564.61 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 4237.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -72.18 | -1339.31 |
F2 NW APARTMENT | 14-JUL-18:30 | 0.00 | -3207.49 | 0.00 | 0.00 | 140.09 | 103.77 | 547.42 | 3351.57 | 0.00 | 173.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1108.83 |
F2 SE APARTMENT | 28-SEP-14:15 | 0.00 | -3439.78 | 0.00 | 0.00 | 40.69 | 22.70 | 400.26 | 3586.64 | 0.00 | 208.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -818.81 |
F2 NE APARTMENT | 13-JUL-10:15 | 0.00 | -2412.00 | 0.00 | 0.00 | 40.75 | 12.97 | 412.03 | 2431.95 | 0.00 | 118.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -604.15 |
F2 N1 APARTMENT | 08-JUL-19:30 | 0.00 | -1694.63 | 0.00 | 0.00 | 140.74 | 103.77 | 523.87 | 1009.15 | 0.00 | 240.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -323.21 |
F2 N2 APARTMENT | 08-JUL-19:30 | 0.00 | -1677.92 | 0.00 | 0.00 | 140.75 | 103.77 | 523.87 | 1009.51 | 0.00 | 240.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -340.55 |
F2 S1 APARTMENT | 31-AUG-13:30 | 0.00 | -2452.59 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3099.37 | 0.00 | 103.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1186.12 |
F2 S2 APARTMENT | 31-AUG-13:30 | 0.00 | -2479.08 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3099.00 | 0.00 | 103.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1159.50 |
F3 SW APARTMENT | 30-SEP-16:05 | 0.00 | -3574.92 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 4204.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -83.94 | -1283.86 |
F3 NW APARTMENT | 08-JUL-19:15 | 0.00 | -3253.57 | 0.00 | 0.00 | 141.81 | 103.77 | 523.87 | 2829.76 | 0.00 | 451.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -797.57 |
F3 SE APARTMENT | 28-SEP-14:15 | 0.00 | -3254.69 | 0.00 | 0.00 | 40.50 | 22.70 | 400.26 | 3574.77 | 0.00 | 210.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -994.25 |
F3 NE APARTMENT | 22-JUN-10:15 | 0.00 | -2479.29 | 0.00 | 0.00 | 40.75 | 12.97 | 412.03 | 2292.83 | 0.00 | 291.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -570.99 |
F3 N1 APARTMENT | 01-JUL-19:38 | 0.00 | -1763.39 | 0.00 | 0.00 | 141.81 | 103.77 | 523.87 | 800.12 | 0.00 | 502.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -308.47 |
F3 N2 APARTMENT | 01-JUL-19:38 | 0.00 | -1746.53 | 0.00 | 0.00 | 141.81 | 103.77 | 523.87 | 800.34 | 0.00 | 501.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -325.06 |
F3 S1 APARTMENT | 05-OCT-13:00 | 0.00 | -2524.09 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 3612.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1530.29 |
F3 S2 APARTMENT | 05-OCT-13:00 | 0.00 | -2536.10 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 3611.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1518.05 |
F4 SW APARTMENT | 30-SEP-16:30 | 0.00 | -3573.78 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 4035.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -98.11 | -1101.40 |
F4 NW APARTMENT | 08-JUL-19:15 | 0.00 | -3291.57 | 0.00 | 0.00 | 141.81 | 103.77 | 523.87 | 2811.57 | 0.00 | 490.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -780.44 |
F4 SE APARTMENT | 28-SEP-14:15 | 0.00 | -3258.20 | 0.00 | 0.00 | 40.53 | 22.70 | 400.26 | 3565.80 | 0.00 | 221.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -992.33 |
F4 NE APARTMENT | 01-JUL-19:45 | 0.00 | -2509.78 | 0.00 | 0.00 | 141.81 | 103.77 | 523.87 | 897.35 | 0.00 | 639.64 | 203.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 N1 APARTMENT | 01-JUL-19:38 | 0.00 | -1780.85 | 0.00 | 0.00 | 141.81 | 103.77 | 523.87 | 795.12 | 0.00 | 543.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -327.40 |
F4 N2 APARTMENT | 01-JUL-19:38 | 0.00 | -1764.06 | 0.00 | 0.00 | 141.81 | 103.77 | 523.87 | 795.34 | 0.00 | 543.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -343.88 |
F4 S1 APARTMENT | 05-OCT-13:00 | 0.00 | -2541.89 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 3611.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1511.90 |
F4 S2 APARTMENT | 05-OCT-13:00 | 0.00 | -2552.03 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 3611.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1501.56 |
M SW APARTMENT | 05-AUG-16:45 | 0.00 | -3618.39 | 0.00 | 0.00 | 83.34 | 64.86 | 588.62 | 3300.72 | 0.00 | 383.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -802.88 |
M NW APARTMENT | 08-JUL-19:15 | 0.00 | -3341.52 | 0.00 | 0.00 | 141.81 | 103.77 | 523.87 | 2797.08 | 0.00 | 522.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -747.21 |
M SE APARTMENT | 28-SEP-14:15 | 0.00 | -3297.52 | 0.00 | 0.00 | 40.59 | 22.70 | 400.26 | 3558.24 | 0.00 | 231.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -955.98 |
M NE APARTMENT | 01-JUL-19:45 | 0.00 | -2578.41 | 0.00 | 0.00 | 141.81 | 103.77 | 523.87 | 893.05 | 0.00 | 683.54 | 232.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N1 APARTMENT | 08-JUL-19:30 | 0.00 | -1825.10 | 0.00 | 0.00 | 140.40 | 103.77 | 523.87 | 984.72 | 0.00 | 305.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -233.30 |
M N2 APARTMENT | 08-JUL-19:30 | 0.00 | -1808.43 | 0.00 | 0.00 | 140.41 | 103.77 | 523.87 | 985.08 | 0.00 | 305.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -250.64 |
M S1 APARTMENT | 05-OCT-13:00 | 0.00 | -2573.34 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 3611.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1479.88 |
M S2 APARTMENT | 05-OCT-13:00 | 0.00 | -2583.20 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 3610.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1469.83 |
F6 SW APARTMENT | 05-AUG-17:00 | 0.00 | -3590.00 | 0.00 | 0.00 | 83.08 | 64.86 | 588.62 | 3209.46 | 0.00 | 432.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -788.58 |
F6 NW APARTMENT | 08-JUL-19:15 | 0.00 | -3324.43 | 0.00 | 0.00 | 141.81 | 103.77 | 523.87 | 2786.75 | 0.00 | 548.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -779.90 |
F6 SE APARTMENT | 06-AUG-14:00 | 0.00 | -3276.58 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 2788.96 | 0.00 | 366.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -315.60 |
F6 NE APARTMENT | 01-JUL-19:45 | 0.00 | -2581.18 | 0.00 | 0.00 | 141.81 | 103.77 | 523.87 | 891.22 | 0.00 | 719.95 | 200.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 N1 APARTMENT | 08-JUL-19:30 | 0.00 | -1798.08 | 0.00 | 0.00 | 140.35 | 103.77 | 523.87 | 980.96 | 0.00 | 317.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -268.63 |
F6 N2 APARTMENT | 08-JUL-19:30 | 0.00 | -1781.09 | 0.00 | 0.00 | 140.36 | 103.77 | 523.87 | 981.32 | 0.00 | 317.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -286.21 |
F6 S1 APARTMENT | 05-OCT-13:15 | 0.00 | -2542.67 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3574.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1467.78 |
F6 S2 APARTMENT | 05-OCT-13:00 | 0.00 | -2553.78 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 3611.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1499.74 |
F7 SW APARTMENT | 05-AUG-17:00 | 0.00 | -3589.32 | 0.00 | 0.00 | 83.00 | 64.86 | 588.62 | 3202.51 | 0.00 | 455.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -805.37 |
F7 NW APARTMENT | 08-JUL-19:15 | 0.00 | -3327.20 | 0.00 | 0.00 | 141.81 | 103.77 | 523.87 | 2777.63 | 0.00 | 570.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -790.04 |
F7 SE APARTMENT | 06-AUG-14:00 | 0.00 | -3281.12 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 2782.97 | 0.00 | 386.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -325.08 |
F7 NE APARTMENT | 01-JUL-19:38 | 0.00 | -2597.28 | 0.00 | 0.00 | 141.81 | 103.77 | 523.87 | 889.03 | 0.00 | 750.40 | 188.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 N1 APARTMENT | 08-JUL-19:30 | 0.00 | -1791.28 | 0.00 | 0.00 | 140.33 | 103.77 | 523.87 | 977.42 | 0.00 | 327.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -282.06 |
F7 N2 APARTMENT | 08-JUL-19:30 | 0.00 | -1774.40 | 0.00 | 0.00 | 140.33 | 103.77 | 523.87 | 977.79 | 0.00 | 328.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -299.53 |
F7 S1 APARTMENT | 05-OCT-13:15 | 0.00 | -2533.99 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3574.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1476.48 |
F7 S2 APARTMENT | 05-OCT-13:15 | 0.00 | -2543.75 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3573.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1466.53 |
F8 SW APARTMENT | 05-AUG-17:10 | 0.00 | -3601.91 | 0.00 | 0.00 | 138.68 | 87.56 | 588.62 | 3148.81 | 0.00 | 421.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -783.23 |
F8 NW APARTMENT | 08-JUL-19:15 | 0.00 | -3339.11 | 0.00 | 0.00 | 141.81 | 103.77 | 523.87 | 2769.38 | 0.00 | 589.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -788.90 |
F8 SE APARTMENT | 06-AUG-14:00 | 0.00 | -3296.09 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 2776.66 | 0.00 | 404.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -321.68 |
F8 NE APARTMENT | 01-JUL-19:38 | 0.00 | -2605.18 | 0.00 | 0.00 | 141.80 | 103.77 | 523.87 | 886.66 | 0.00 | 774.13 | 174.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 N1 APARTMENT | 08-JUL-19:30 | 0.00 | -1798.66 | 0.00 | 0.00 | 140.33 | 103.77 | 523.87 | 974.12 | 0.00 | 337.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -280.81 |
F8 N2 APARTMENT | 08-JUL-19:30 | 0.00 | -1781.92 | 0.00 | 0.00 | 140.33 | 103.77 | 523.87 | 974.48 | 0.00 | 337.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -298.14 |
F8 S1 APARTMENT | 31-AUG-13:45 | 0.00 | -2522.13 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 2964.59 | 0.00 | 181.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1060.56 |
F8 S2 APARTMENT | 31-AUG-13:45 | 0.00 | -2532.75 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 2964.36 | 0.00 | 181.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1049.51 |
F9 SW APARTMENT | 05-AUG-17:10 | 0.00 | -3722.48 | 0.00 | 0.00 | 138.84 | 87.56 | 588.62 | 3141.37 | 0.00 | 439.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -673.01 |
F9 NW APARTMENT | 08-JUL-19:15 | 0.00 | -3435.67 | 0.00 | 0.00 | 141.81 | 103.77 | 523.87 | 2758.99 | 0.00 | 605.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -698.54 |
F9 SE APARTMENT | 06-AUG-14:00 | 0.00 | -3381.00 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 2769.16 | 0.00 | 420.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -245.47 |
F9 NE APARTMENT | 01-JUL-19:38 | 0.00 | -2654.60 | 0.00 | 0.00 | 141.80 | 103.77 | 523.87 | 881.67 | 0.00 | 790.29 | 213.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 N1 APARTMENT | 08-JUL-19:30 | 0.00 | -1898.02 | 0.00 | 0.00 | 140.47 | 103.77 | 523.87 | 969.44 | 0.00 | 351.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -191.30 |
F9 N2 APARTMENT | 08-JUL-19:15 | 0.00 | -1881.42 | 0.00 | 0.00 | 141.81 | 103.77 | 523.87 | 907.49 | 0.00 | 514.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -310.07 |
F9 S1 APARTMENT | 31-AUG-14:00 | 0.00 | -2582.52 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 2861.17 | 0.00 | 239.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -954.70 |
F9 S2 APARTMENT | 31-AUG-14:00 | 0.00 | -2593.90 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 2860.93 | 0.00 | 239.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -942.90 |
T SW APARTMENT | 05-AUG-16:45 | 0.00 | -4640.89 | 0.00 | 0.00 | 84.39 | 64.86 | 588.62 | 3226.20 | 0.00 | 497.02 | 179.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 12-JUL-17:45 | 0.00 | -4214.26 | 0.00 | 0.00 | 135.53 | 87.56 | 588.62 | 3327.59 | 0.00 | 550.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -475.26 |
T SE APARTMENT | 01-OCT-12:45 | 0.00 | -4129.38 | 0.00 | 0.00 | 40.60 | 12.97 | 388.49 | 4324.01 | 0.00 | 183.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -820.55 |
T NE APARTMENT | 12-JUL-17:20 | 0.00 | -3284.09 | 0.00 | 0.00 | 139.56 | 87.56 | 588.62 | 1042.11 | 0.00 | 599.33 | 826.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 01-JUL-19:45 | 0.00 | -2530.41 | 0.00 | 0.00 | 141.81 | 103.77 | 523.87 | 769.19 | 0.00 | 745.69 | 246.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 01-JUL-19:45 | 0.00 | -2506.23 | 0.00 | 0.00 | 141.81 | 103.77 | 523.87 | 769.76 | 0.00 | 745.68 | 221.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 28-SEP-14:15 | 0.00 | -3426.04 | 0.00 | 0.00 | 40.45 | 22.70 | 400.26 | 3230.55 | 0.00 | 224.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -492.67 |
T S2 APARTMENT | 28-SEP-14:15 | 0.00 | -3433.76 | 0.00 | 0.00 | 40.45 | 22.70 | 400.26 | 3230.34 | 0.00 | 224.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -484.74 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 06-AUG-16:10 | 0.00 | -201404.54 | 0.00 | 0.00 | 6669.08 | 11327.17 | 47212.47 | 132461.68 | 0.00 | 31767.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -28033.11 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 04-JAN-08:15 | 1828.82 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1121.51 | 0.00 | -750.31 | -438.91 |
G NW APARTMENT | 13-JAN-08:30 | 1907.17 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1264.46 | 0.00 | -319.48 | -805.15 |
OFFICE | 28-DEC-07:50 | 1724.46 | 0.00 | 0.00 | 0.00 | 0.00 | 469.18 | 294.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1116.45 | 0.00 | -827.31 | -544.18 |
G NE APARTMENT | 04-JAN-08:15 | 1900.20 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1116.08 | 0.00 | -750.31 | -515.73 |
G N1 APARTMENT | 03-MAR-13:35 | 1289.45 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 388.49 | 347.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1480.49 | -605.53 |
G N2 APARTMENT | 03-MAR-13:35 | 1288.56 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 388.49 | 347.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1480.49 | -604.59 |
G S1 APARTMENT | 07-NOV-09:55 | 1168.98 | 0.00 | 0.00 | 0.00 | 45.61 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -94.24 | 0.00 | -1301.91 | -225.78 |
G S2 APARTMENT | 28-DEC-08:05 | 1077.69 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -678.07 | 0.00 | -482.94 | -398.59 |
F2 SW APARTMENT | 28-DEC-08:05 | 1903.01 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1150.66 | 0.00 | -1151.46 | -82.81 |
F2 NW APARTMENT | 28-DEC-10:00 | 2120.15 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -882.52 | 0.00 | -1370.67 | -321.72 |
F2 SE APARTMENT | 28-DEC-08:05 | 1846.19 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1160.01 | 0.00 | -1151.46 | -16.63 |
F2 NE APARTMENT | 04-JAN-05:00 | 2042.14 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1154.29 | 0.00 | -1132.54 | -188.11 |
F2 N1 APARTMENT | 03-MAR-13:40 | 1881.74 | 0.00 | 0.00 | 0.00 | 46.69 | 12.97 | 388.49 | 321.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1979.49 | -671.88 |
F2 N2 APARTMENT | 03-MAR-13:40 | 1880.69 | 0.00 | 0.00 | 0.00 | 46.69 | 12.97 | 388.49 | 321.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1979.47 | -670.73 |
F2 S1 APARTMENT | 07-NOV-10:00 | 1170.67 | 0.00 | 0.00 | 0.00 | 42.64 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 146.32 | 0.00 | -137.89 | 0.00 | -1629.08 | 0.00 |
F2 S2 APARTMENT | 07-NOV-10:00 | 1110.00 | 0.00 | 0.00 | 0.00 | 42.52 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 210.94 | 0.00 | -139.14 | 0.00 | -1631.66 | 0.00 |
F3 SW APARTMENT | 28-DEC-08:05 | 2055.10 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1166.92 | 0.00 | -1363.98 | -6.11 |
F3 NW APARTMENT | 28-DEC-10:00 | 2311.46 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -899.15 | 0.00 | -1623.70 | -243.36 |
F3 SE APARTMENT | 28-DEC-08:05 | 2049.16 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 8.86 | 0.00 | -1175.95 | 0.00 | -1363.98 | 0.00 |
F3 NE APARTMENT | 04-JAN-05:00 | 2177.87 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1170.29 | 0.00 | -1341.55 | -98.83 |
F3 N1 APARTMENT | 03-MAR-13:40 | 2198.03 | 0.00 | 0.00 | 0.00 | 46.50 | 12.97 | 388.49 | 312.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2298.63 | -659.79 |
F3 N2 APARTMENT | 03-MAR-13:40 | 2199.03 | 0.00 | 0.00 | 0.00 | 46.50 | 12.97 | 388.49 | 312.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2298.62 | -660.65 |
F3 S1 APARTMENT | 07-NOV-10:00 | 1755.40 | 0.00 | 0.00 | 0.00 | 41.70 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -155.14 | 0.00 | -1842.22 | -207.08 |
F3 S2 APARTMENT | 07-NOV-10:00 | 1772.85 | 0.00 | 0.00 | 0.00 | 41.67 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -155.43 | 0.00 | -1842.38 | -224.06 |
F4 SW APARTMENT | 28-DEC-08:05 | 2201.27 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 18.80 | 0.00 | -1176.60 | 0.00 | -1525.38 | 0.00 |
F4 NW APARTMENT | 28-DEC-10:00 | 2490.69 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -909.29 | 0.00 | -1815.89 | -220.28 |
F4 SE APARTMENT | 28-DEC-08:05 | 2205.11 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 24.67 | 0.00 | -1186.32 | 0.00 | -1525.38 | 0.00 |
F4 NE APARTMENT | 04-JAN-05:00 | 2320.73 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1179.99 | 0.00 | -1500.27 | -73.27 |
F4 N1 APARTMENT | 03-MAR-13:40 | 2407.32 | 0.00 | 0.00 | 0.00 | 46.53 | 12.97 | 388.49 | 308.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2547.62 | -616.07 |
F4 N2 APARTMENT | 03-MAR-13:40 | 2407.01 | 0.00 | 0.00 | 0.00 | 46.53 | 12.97 | 388.49 | 308.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2547.60 | -615.64 |
F4 S1 APARTMENT | 03-MAR-13:45 | 1595.42 | 0.00 | 0.00 | 0.00 | 41.57 | 12.97 | 388.49 | 2844.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2555.87 | -2327.29 |
F4 S2 APARTMENT | 03-MAR-13:45 | 1569.22 | 0.00 | 0.00 | 0.00 | 41.52 | 12.97 | 388.49 | 2844.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2556.76 | -2299.53 |
M SW APARTMENT | 28-DEC-08:05 | 2313.81 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 47.85 | 0.00 | -1184.97 | 0.00 | -1658.60 | 0.00 |
M NW APARTMENT | 28-DEC-10:00 | 2628.65 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -917.47 | 0.00 | -1974.55 | -191.39 |
M SE APARTMENT | 28-DEC-08:05 | 2319.64 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 52.77 | 0.00 | -1195.73 | 0.00 | -1658.60 | 0.00 |
M NE APARTMENT | 03-MAR-13:40 | 2499.01 | 0.00 | 0.00 | 0.00 | 47.31 | 12.97 | 388.49 | 517.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2956.51 | -508.33 |
M N1 APARTMENT | 03-MAR-13:40 | 2587.87 | 0.00 | 0.00 | 0.00 | 46.55 | 12.97 | 388.49 | 305.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2757.45 | -583.68 |
M N2 APARTMENT | 03-MAR-13:40 | 2587.80 | 0.00 | 0.00 | 0.00 | 46.54 | 12.97 | 388.49 | 305.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2757.44 | -583.47 |
M S1 APARTMENT | 03-MAR-13:45 | 1784.90 | 0.00 | 0.00 | 0.00 | 41.74 | 12.97 | 388.49 | 2828.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2762.19 | -2294.20 |
M S2 APARTMENT | 03-MAR-13:45 | 1790.06 | 0.00 | 0.00 | 0.00 | 41.71 | 12.97 | 388.49 | 2827.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2762.30 | -2298.79 |
F6 SW APARTMENT | 28-DEC-08:05 | 2462.22 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 18.96 | 0.00 | -1189.53 | 0.00 | -1773.57 | 0.00 |
F6 NW APARTMENT | 28-DEC-10:00 | 2798.69 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -922.19 | 0.00 | -2111.49 | -219.77 |
F6 SE APARTMENT | 28-DEC-08:05 | 2468.76 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 23.84 | 0.00 | -1200.95 | 0.00 | -1773.57 | 0.00 |
F6 NE APARTMENT | 03-MAR-13:45 | 2712.23 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 388.49 | 516.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3154.91 | -522.83 |
F6 N1 APARTMENT | 03-MAR-13:40 | 2676.84 | 0.00 | 0.00 | 0.00 | 46.85 | 12.97 | 388.49 | 306.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2941.11 | -490.11 |
F6 N2 APARTMENT | 03-MAR-13:40 | 2676.84 | 0.00 | 0.00 | 0.00 | 46.85 | 12.97 | 388.49 | 305.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2941.10 | -489.96 |
F6 S1 APARTMENT | 03-MAR-13:45 | 1847.35 | 0.00 | 0.00 | 0.00 | 42.27 | 12.97 | 388.49 | 2820.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2945.05 | -2166.42 |
F6 S2 APARTMENT | 03-MAR-13:45 | 1852.22 | 0.00 | 0.00 | 0.00 | 42.24 | 12.97 | 388.49 | 2820.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2945.15 | -2170.79 |
F7 SW APARTMENT | 28-DEC-08:05 | 2581.19 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 6.34 | 0.00 | -1193.87 | 0.00 | -1875.58 | 0.00 |
F7 NW APARTMENT | 28-DEC-10:00 | 2935.98 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -926.66 | 0.00 | -2233.01 | -231.07 |
F7 SE APARTMENT | 28-DEC-08:05 | 2588.19 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 11.30 | 0.00 | -1205.83 | 0.00 | -1875.58 | 0.00 |
F7 NE APARTMENT | 03-MAR-13:45 | 2916.51 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 388.49 | 515.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3333.78 | -546.86 |
F7 N1 APARTMENT | 03-MAR-13:40 | 2778.45 | 0.00 | 0.00 | 0.00 | 47.06 | 12.97 | 388.49 | 306.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3106.68 | -426.48 |
F7 N2 APARTMENT | 03-MAR-13:40 | 2778.77 | 0.00 | 0.00 | 0.00 | 47.05 | 12.97 | 388.49 | 306.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3106.69 | -426.63 |
F7 S1 APARTMENT | 03-MAR-13:45 | 1901.61 | 0.00 | 0.00 | 0.00 | 42.71 | 12.97 | 388.49 | 2813.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3109.92 | -2049.60 |
F7 S2 APARTMENT | 03-MAR-13:45 | 1900.33 | 0.00 | 0.00 | 0.00 | 42.68 | 12.97 | 388.49 | 2813.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3110.01 | -2047.83 |
F8 SW APARTMENT | 03-MAR-13:40 | 2889.88 | 0.00 | 0.00 | 0.00 | 44.42 | 12.97 | 388.49 | 3269.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3515.38 | -3090.25 |
F8 NW APARTMENT | 03-MAR-13:45 | 3073.13 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 388.49 | 787.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3497.76 | -812.09 |
F8 SE APARTMENT | 03-MAR-13:40 | 2983.32 | 0.00 | 0.00 | 0.00 | 44.49 | 12.97 | 388.49 | 2997.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3510.83 | -2915.85 |
F8 NE APARTMENT | 03-MAR-13:45 | 3100.95 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 388.49 | 514.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3497.76 | -566.07 |
F8 N1 APARTMENT | 03-MAR-13:40 | 2881.57 | 0.00 | 0.00 | 0.00 | 47.22 | 12.97 | 388.49 | 306.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3258.56 | -377.86 |
F8 N2 APARTMENT | 03-MAR-13:40 | 2881.39 | 0.00 | 0.00 | 0.00 | 47.22 | 12.97 | 388.49 | 306.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3258.57 | -377.52 |
F8 S1 APARTMENT | 03-MAR-13:40 | 2299.93 | 0.00 | 0.00 | 0.00 | 43.07 | 12.97 | 388.49 | 2808.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3294.20 | -2258.28 |
F8 S2 APARTMENT | 03-MAR-13:40 | 2281.40 | 0.00 | 0.00 | 0.00 | 43.04 | 12.97 | 388.49 | 2807.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3295.02 | -2238.52 |
F9 SW APARTMENT | 03-MAR-13:40 | 3104.92 | 0.00 | 0.00 | 0.00 | 44.84 | 12.97 | 388.49 | 3267.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3662.13 | -3156.69 |
F9 NW APARTMENT | 03-MAR-13:45 | 3273.60 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 388.49 | 787.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3650.07 | -859.92 |
F9 SE APARTMENT | 03-MAR-13:40 | 3124.77 | 0.00 | 0.00 | 0.00 | 44.92 | 12.97 | 388.49 | 2996.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3660.10 | -2907.69 |
F9 NE APARTMENT | 03-MAR-13:45 | 3300.13 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 388.49 | 515.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3650.07 | -614.10 |
F9 N1 APARTMENT | 03-MAR-13:35 | 3009.64 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 388.49 | 307.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3399.59 | -366.75 |
F9 N2 APARTMENT | 03-MAR-13:35 | 3007.05 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 388.49 | 307.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3399.56 | -364.08 |
F9 S1 APARTMENT | 03-MAR-13:40 | 2835.13 | 0.00 | 0.00 | 0.00 | 43.59 | 12.97 | 388.49 | 2805.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3422.74 | -2663.36 |
F9 S2 APARTMENT | 03-MAR-13:40 | 2816.95 | 0.00 | 0.00 | 0.00 | 43.56 | 12.97 | 388.49 | 2805.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3423.53 | -2643.98 |
T SW APARTMENT | 04-JAN-05:00 | 3591.10 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1184.63 | 0.00 | -2095.49 | -743.78 |
T NW APARTMENT | 28-DEC-10:00 | 3742.75 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -908.91 | 0.00 | -2537.03 | -751.58 |
T SE APARTMENT | 04-JAN-05:00 | 3598.29 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1197.33 | 0.00 | -2095.49 | -738.27 |
T NE APARTMENT | 04-JAN-05:00 | 3658.67 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1172.16 | 0.00 | -2095.49 | -823.82 |
T N1 APARTMENT | 03-MAR-13:40 | 3163.48 | 0.00 | 0.00 | 0.00 | 47.15 | 12.97 | 388.49 | 304.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3532.83 | -383.57 |
T N2 APARTMENT | 03-MAR-13:40 | 3165.44 | 0.00 | 0.00 | 0.00 | 47.14 | 12.97 | 388.49 | 304.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3532.85 | -385.39 |
T S1 APARTMENT | 03-MAR-13:40 | 2434.55 | 0.00 | 0.00 | 0.00 | 42.19 | 12.97 | 388.49 | 2774.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3597.93 | -2055.14 |
T S2 APARTMENT | 03-MAR-13:40 | 2423.98 | 0.00 | 0.00 | 0.00 | 42.17 | 12.97 | 388.49 | 2774.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3598.73 | -2043.50 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 03-MAR-13:40 | 158926.20 | 0.00 | 0.00 | 0.00 | 3627.78 | 9104.94 | 31440.07 | 141187.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -229763.77 | -114522.53 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:31
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:31
Sec1.1A-General InformationData | |
Weather File | Boise Air Terminal Uo ID USA TMY3 WMO#=726810 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 7836.48 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.50 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F2 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F3 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F4 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F6 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F7 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F8 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F9 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 7836.48 | 7059.89 | 776.58 |
Data | |
Number of hours heating loads not met | 133.00 |
Number of hours cooling loads not met | 179.25 |
Number of hours not met | 312.25 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 296.56 | 13120.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 162.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 159.58 | 0.00 | 544.55 | 187866.75 | 0.00 | 0.00 |
Space Cooling | 353.52 | 70644.80 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 61.16 | 1965.77 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 12.51 | 2475.14 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 750.51 | 23798.64 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 0.00 | 0.00 | 1165.01 | 80520.40 | 0.00 | 0.00 |
Receptacle Equipment | 1137.32 | 57042.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 2969.94 | 1709.56 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 1137.32 | 2969.94 |
Natural Gas | 0.00 | 1709.56 |
Additional | 0.00 | 0.00 |
Total | 1137.32 | 4679.50 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 37.84 |
Space Heating | 20.36 |
Space Cooling | 45.11 |
Fans-Interior | 95.77 |
Service Water Heating | 0.00 |
Receptacle Equipment | 145.13 |
Miscellaneous | 34.77 |
Subtotal | 378.99 |
Natural Gas [MJ/m2] | |
Space Heating | 69.49 |
Service Water Heating | 148.66 |
Miscellaneous | 0.00 |
Subtotal | 218.15 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 6.34 |
Space Heating | 15.05 |
Space Cooling | 7.55 |
Fans-Interior | 16.04 |
Service Water Heating | 24.90 |
Receptacle Equipment | 24.30 |
Miscellaneous | 5.82 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:31
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.266307 |
G NW APARTMENT DIRECT AIR | 0.245974 |
OFFICE DIRECT AIR | 0.385195 |
G NE APARTMENT DIRECT AIR | 0.178831 |
G N1 APARTMENT DIRECT AIR | 0.120314 |
G N2 APARTMENT DIRECT AIR | 0.118360 |
G S1 APARTMENT DIRECT AIR | 0.164237 |
G S2 APARTMENT DIRECT AIR | 0.170995 |
F2 SW APARTMENT DIRECT AIR | 0.340752 |
F2 NW APARTMENT DIRECT AIR | 0.310262 |
F2 SE APARTMENT DIRECT AIR | 0.327454 |
F2 NE APARTMENT DIRECT AIR | 0.238457 |
F2 N1 APARTMENT DIRECT AIR | 0.159432 |
F2 N2 APARTMENT DIRECT AIR | 0.157864 |
F2 S1 APARTMENT DIRECT AIR | 0.214707 |
F2 S2 APARTMENT DIRECT AIR | 0.217214 |
F3 SW APARTMENT DIRECT AIR | 0.343432 |
F3 NW APARTMENT DIRECT AIR | 0.313937 |
F3 SE APARTMENT DIRECT AIR | 0.310405 |
F3 NE APARTMENT DIRECT AIR | 0.243881 |
F3 N1 APARTMENT DIRECT AIR | 0.163563 |
F3 N2 APARTMENT DIRECT AIR | 0.162001 |
F3 S1 APARTMENT DIRECT AIR | 0.219865 |
F3 S2 APARTMENT DIRECT AIR | 0.221042 |
F4 SW APARTMENT DIRECT AIR | 0.346018 |
F4 NW APARTMENT DIRECT AIR | 0.316536 |
F4 SE APARTMENT DIRECT AIR | 0.312031 |
F4 NE APARTMENT DIRECT AIR | 0.246639 |
F4 N1 APARTMENT DIRECT AIR | 0.165741 |
F4 N2 APARTMENT DIRECT AIR | 0.164183 |
F4 S1 APARTMENT DIRECT AIR | 0.222651 |
F4 S2 APARTMENT DIRECT AIR | 0.223639 |
M SW APARTMENT DIRECT AIR | 0.350310 |
M NW APARTMENT DIRECT AIR | 0.320861 |
M SE APARTMENT DIRECT AIR | 0.317028 |
M NE APARTMENT DIRECT AIR | 0.251089 |
M N1 APARTMENT DIRECT AIR | 0.169545 |
M N2 APARTMENT DIRECT AIR | 0.167992 |
M S1 APARTMENT DIRECT AIR | 0.226969 |
M S2 APARTMENT DIRECT AIR | 0.227929 |
F6 SW APARTMENT DIRECT AIR | 0.348302 |
F6 NW APARTMENT DIRECT AIR | 0.318735 |
F6 SE APARTMENT DIRECT AIR | 0.315863 |
F6 NE APARTMENT DIRECT AIR | 0.249205 |
F6 N1 APARTMENT DIRECT AIR | 0.167288 |
F6 N2 APARTMENT DIRECT AIR | 0.165746 |
F6 S1 APARTMENT DIRECT AIR | 0.225085 |
F6 S2 APARTMENT DIRECT AIR | 0.226041 |
F7 SW APARTMENT DIRECT AIR | 0.348372 |
F7 NW APARTMENT DIRECT AIR | 0.318782 |
F7 SE APARTMENT DIRECT AIR | 0.316679 |
F7 NE APARTMENT DIRECT AIR | 0.249425 |
F7 N1 APARTMENT DIRECT AIR | 0.167115 |
F7 N2 APARTMENT DIRECT AIR | 0.165581 |
F7 S1 APARTMENT DIRECT AIR | 0.225227 |
F7 S2 APARTMENT DIRECT AIR | 0.226182 |
F8 SW APARTMENT DIRECT AIR | 0.349698 |
F8 NW APARTMENT DIRECT AIR | 0.320098 |
F8 SE APARTMENT DIRECT AIR | 0.318580 |
F8 NE APARTMENT DIRECT AIR | 0.250791 |
F8 N1 APARTMENT DIRECT AIR | 0.168238 |
F8 N2 APARTMENT DIRECT AIR | 0.166714 |
F8 S1 APARTMENT DIRECT AIR | 0.226545 |
F8 S2 APARTMENT DIRECT AIR | 0.227502 |
F9 SW APARTMENT DIRECT AIR | 0.361483 |
F9 NW APARTMENT DIRECT AIR | 0.331466 |
F9 SE APARTMENT DIRECT AIR | 0.327754 |
F9 NE APARTMENT DIRECT AIR | 0.255699 |
F9 N1 APARTMENT DIRECT AIR | 0.178010 |
F9 N2 APARTMENT DIRECT AIR | 0.176478 |
F9 S1 APARTMENT DIRECT AIR | 0.234054 |
F9 S2 APARTMENT DIRECT AIR | 0.235107 |
T SW APARTMENT DIRECT AIR | 0.446752 |
T NW APARTMENT DIRECT AIR | 0.405202 |
T SE APARTMENT DIRECT AIR | 0.409650 |
T NE APARTMENT DIRECT AIR | 0.319637 |
T N1 APARTMENT DIRECT AIR | 0.240293 |
T N2 APARTMENT DIRECT AIR | 0.240115 |
T S1 APARTMENT DIRECT AIR | 0.326633 |
T S2 APARTMENT DIRECT AIR | 0.327472 |
Maximum Flow Rate [m3/s] | |
AIRLOOP G SW MAIN BRANCH | 0.266307 |
AIRLOOP G NW MAIN BRANCH | 0.245974 |
AIRLOOP OFFICE MAIN BRANCH | 0.385195 |
AIRLOOP G NE MAIN BRANCH | 0.178831 |
AIRLOOP G N1 MAIN BRANCH | 0.120314 |
AIRLOOP G N2 MAIN BRANCH | 0.118360 |
AIRLOOP G S1 MAIN BRANCH | 0.164237 |
AIRLOOP G S2 MAIN BRANCH | 0.170995 |
AIRLOOP F2 SW MAIN BRANCH | 0.340752 |
AIRLOOP F2 NW MAIN BRANCH | 0.310262 |
AIRLOOP F2 SE MAIN BRANCH | 0.327454 |
AIRLOOP F2 NE MAIN BRANCH | 0.238457 |
AIRLOOP F2 N1 MAIN BRANCH | 0.159432 |
AIRLOOP F2 N2 MAIN BRANCH | 0.157864 |
AIRLOOP F2 S1 MAIN BRANCH | 0.214707 |
AIRLOOP F2 S2 MAIN BRANCH | 0.217214 |
AIRLOOP F3 SW MAIN BRANCH | 0.343432 |
AIRLOOP F3 NW MAIN BRANCH | 0.313937 |
AIRLOOP F3 SE MAIN BRANCH | 0.310405 |
AIRLOOP F3 NE MAIN BRANCH | 0.243881 |
AIRLOOP F3 N1 MAIN BRANCH | 0.163563 |
AIRLOOP F3 N2 MAIN BRANCH | 0.162001 |
AIRLOOP F3 S1 MAIN BRANCH | 0.219865 |
AIRLOOP F3 S2 MAIN BRANCH | 0.221042 |
AIRLOOP F4 SW MAIN BRANCH | 0.346018 |
AIRLOOP F4 NW MAIN BRANCH | 0.316536 |
AIRLOOP F4 SE MAIN BRANCH | 0.312031 |
AIRLOOP F4 NE MAIN BRANCH | 0.246639 |
AIRLOOP F4 N1 MAIN BRANCH | 0.165741 |
AIRLOOP F4 N2 MAIN BRANCH | 0.164183 |
AIRLOOP F4 S1 MAIN BRANCH | 0.222651 |
AIRLOOP F4 S2 MAIN BRANCH | 0.223639 |
AIRLOOP M SW MAIN BRANCH | 0.350310 |
AIRLOOP M NW MAIN BRANCH | 0.320861 |
AIRLOOP M SE MAIN BRANCH | 0.317028 |
AIRLOOP M NE MAIN BRANCH | 0.251089 |
AIRLOOP M N1 MAIN BRANCH | 0.169545 |
AIRLOOP M N2 MAIN BRANCH | 0.167992 |
AIRLOOP M S1 MAIN BRANCH | 0.226969 |
AIRLOOP M S2 MAIN BRANCH | 0.227929 |
AIRLOOP F6 SW MAIN BRANCH | 0.348302 |
AIRLOOP F6 NW MAIN BRANCH | 0.318735 |
AIRLOOP F6 SE MAIN BRANCH | 0.315863 |
AIRLOOP F6 NE MAIN BRANCH | 0.249205 |
AIRLOOP F6 N1 MAIN BRANCH | 0.167288 |
AIRLOOP F6 N2 MAIN BRANCH | 0.165746 |
AIRLOOP F6 S1 MAIN BRANCH | 0.225085 |
AIRLOOP F6 S2 MAIN BRANCH | 0.226041 |
AIRLOOP F7 SW MAIN BRANCH | 0.348372 |
AIRLOOP F7 NW MAIN BRANCH | 0.318782 |
AIRLOOP F7 SE MAIN BRANCH | 0.316679 |
AIRLOOP F7 NE MAIN BRANCH | 0.249425 |
AIRLOOP F7 N1 MAIN BRANCH | 0.167115 |
AIRLOOP F7 N2 MAIN BRANCH | 0.165581 |
AIRLOOP F7 S1 MAIN BRANCH | 0.225227 |
AIRLOOP F7 S2 MAIN BRANCH | 0.226182 |
AIRLOOP F8 SW MAIN BRANCH | 0.349698 |
AIRLOOP F8 NW MAIN BRANCH | 0.320098 |
AIRLOOP F8 SE MAIN BRANCH | 0.318580 |
AIRLOOP F8 NE MAIN BRANCH | 0.250791 |
AIRLOOP F8 N1 MAIN BRANCH | 0.168238 |
AIRLOOP F8 N2 MAIN BRANCH | 0.166714 |
AIRLOOP F8 S1 MAIN BRANCH | 0.226545 |
AIRLOOP F8 S2 MAIN BRANCH | 0.227502 |
AIRLOOP F9 SW MAIN BRANCH | 0.361483 |
AIRLOOP F9 NW MAIN BRANCH | 0.331466 |
AIRLOOP F9 SE MAIN BRANCH | 0.327754 |
AIRLOOP F9 NE MAIN BRANCH | 0.255699 |
AIRLOOP F9 N1 MAIN BRANCH | 0.178010 |
AIRLOOP F9 N2 MAIN BRANCH | 0.176478 |
AIRLOOP F9 S1 MAIN BRANCH | 0.234054 |
AIRLOOP F9 S2 MAIN BRANCH | 0.235107 |
AIRLOOP T SW MAIN BRANCH | 0.446752 |
AIRLOOP T NW MAIN BRANCH | 0.405202 |
AIRLOOP T SE MAIN BRANCH | 0.409650 |
AIRLOOP T NE MAIN BRANCH | 0.319637 |
AIRLOOP T N1 MAIN BRANCH | 0.240293 |
AIRLOOP T N2 MAIN BRANCH | 0.240115 |
AIRLOOP T S1 MAIN BRANCH | 0.326633 |
AIRLOOP T S2 MAIN BRANCH | 0.327472 |
Design Supply Air Flow Rate [m3/s] | |
AIRLOOP G SW | 0.266307 |
AIRLOOP G NW | 0.245974 |
AIRLOOP OFFICE | 0.385195 |
AIRLOOP G NE | 0.178831 |
AIRLOOP G N1 | 0.120314 |
AIRLOOP G N2 | 0.118360 |
AIRLOOP G S1 | 0.164237 |
AIRLOOP G S2 | 0.170995 |
AIRLOOP F2 SW | 0.340752 |
AIRLOOP F2 NW | 0.310262 |
AIRLOOP F2 SE | 0.327454 |
AIRLOOP F2 NE | 0.238457 |
AIRLOOP F2 N1 | 0.159432 |
AIRLOOP F2 N2 | 0.157864 |
AIRLOOP F2 S1 | 0.214707 |
AIRLOOP F2 S2 | 0.217214 |
AIRLOOP F3 SW | 0.343432 |
AIRLOOP F3 NW | 0.313937 |
AIRLOOP F3 SE | 0.310405 |
AIRLOOP F3 NE | 0.243881 |
AIRLOOP F3 N1 | 0.163563 |
AIRLOOP F3 N2 | 0.162001 |
AIRLOOP F3 S1 | 0.219865 |
AIRLOOP F3 S2 | 0.221042 |
AIRLOOP F4 SW | 0.346018 |
AIRLOOP F4 NW | 0.316536 |
AIRLOOP F4 SE | 0.312031 |
AIRLOOP F4 NE | 0.246639 |
AIRLOOP F4 N1 | 0.165741 |
AIRLOOP F4 N2 | 0.164183 |
AIRLOOP F4 S1 | 0.222651 |
AIRLOOP F4 S2 | 0.223639 |
AIRLOOP M SW | 0.350310 |
AIRLOOP M NW | 0.320861 |
AIRLOOP M SE | 0.317028 |
AIRLOOP M NE | 0.251089 |
AIRLOOP M N1 | 0.169545 |
AIRLOOP M N2 | 0.167992 |
AIRLOOP M S1 | 0.226969 |
AIRLOOP M S2 | 0.227929 |
AIRLOOP F6 SW | 0.348302 |
AIRLOOP F6 NW | 0.318735 |
AIRLOOP F6 SE | 0.315863 |
AIRLOOP F6 NE | 0.249205 |
AIRLOOP F6 N1 | 0.167288 |
AIRLOOP F6 N2 | 0.165746 |
AIRLOOP F6 S1 | 0.225085 |
AIRLOOP F6 S2 | 0.226041 |
AIRLOOP F7 SW | 0.348372 |
AIRLOOP F7 NW | 0.318782 |
AIRLOOP F7 SE | 0.316679 |
AIRLOOP F7 NE | 0.249425 |
AIRLOOP F7 N1 | 0.167115 |
AIRLOOP F7 N2 | 0.165581 |
AIRLOOP F7 S1 | 0.225227 |
AIRLOOP F7 S2 | 0.226182 |
AIRLOOP F8 SW | 0.349698 |
AIRLOOP F8 NW | 0.320098 |
AIRLOOP F8 SE | 0.318580 |
AIRLOOP F8 NE | 0.250791 |
AIRLOOP F8 N1 | 0.168238 |
AIRLOOP F8 N2 | 0.166714 |
AIRLOOP F8 S1 | 0.226545 |
AIRLOOP F8 S2 | 0.227502 |
AIRLOOP F9 SW | 0.361483 |
AIRLOOP F9 NW | 0.331466 |
AIRLOOP F9 SE | 0.327754 |
AIRLOOP F9 NE | 0.255699 |
AIRLOOP F9 N1 | 0.178010 |
AIRLOOP F9 N2 | 0.176478 |
AIRLOOP F9 S1 | 0.234054 |
AIRLOOP F9 S2 | 0.235107 |
AIRLOOP T SW | 0.446752 |
AIRLOOP T NW | 0.405202 |
AIRLOOP T SE | 0.409650 |
AIRLOOP T NE | 0.319637 |
AIRLOOP T N1 | 0.240293 |
AIRLOOP T N2 | 0.240115 |
AIRLOOP T S1 | 0.326633 |
AIRLOOP T S2 | 0.327472 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
AIRLOOP G SW OA CONTROLLER | 0.266307 | 0.025952 |
AIRLOOP G NW OA CONTROLLER | 0.245974 | 0.025952 |
AIRLOOP OFFICE OA CONTROLLER | 0.385195 | 0.038103 |
AIRLOOP G NE OA CONTROLLER | 0.178831 | 0.025952 |
AIRLOOP G N1 OA CONTROLLER | 0.120314 | 0.025952 |
AIRLOOP G N2 OA CONTROLLER | 0.118360 | 0.025952 |
AIRLOOP G S1 OA CONTROLLER | 0.164237 | 0.025952 |
AIRLOOP G S2 OA CONTROLLER | 0.170995 | 0.025952 |
AIRLOOP F2 SW OA CONTROLLER | 0.340752 | 0.025952 |
AIRLOOP F2 NW OA CONTROLLER | 0.310262 | 0.025952 |
AIRLOOP F2 SE OA CONTROLLER | 0.327454 | 0.025952 |
AIRLOOP F2 NE OA CONTROLLER | 0.238457 | 0.025952 |
AIRLOOP F2 N1 OA CONTROLLER | 0.159432 | 0.025952 |
AIRLOOP F2 N2 OA CONTROLLER | 0.157864 | 0.025952 |
AIRLOOP F2 S1 OA CONTROLLER | 0.214707 | 0.025952 |
AIRLOOP F2 S2 OA CONTROLLER | 0.217214 | 0.025952 |
AIRLOOP F3 SW OA CONTROLLER | 0.343432 | 0.025952 |
AIRLOOP F3 NW OA CONTROLLER | 0.313937 | 0.025952 |
AIRLOOP F3 SE OA CONTROLLER | 0.310405 | 0.025952 |
AIRLOOP F3 NE OA CONTROLLER | 0.243881 | 0.025952 |
AIRLOOP F3 N1 OA CONTROLLER | 0.163563 | 0.025952 |
AIRLOOP F3 N2 OA CONTROLLER | 0.162001 | 0.025952 |
AIRLOOP F3 S1 OA CONTROLLER | 0.219865 | 0.025952 |
AIRLOOP F3 S2 OA CONTROLLER | 0.221042 | 0.025952 |
AIRLOOP F4 SW OA CONTROLLER | 0.346018 | 0.025952 |
AIRLOOP F4 NW OA CONTROLLER | 0.316536 | 0.025952 |
AIRLOOP F4 SE OA CONTROLLER | 0.312031 | 0.025952 |
AIRLOOP F4 NE OA CONTROLLER | 0.246639 | 0.025952 |
AIRLOOP F4 N1 OA CONTROLLER | 0.165741 | 0.025952 |
AIRLOOP F4 N2 OA CONTROLLER | 0.164183 | 0.025952 |
AIRLOOP F4 S1 OA CONTROLLER | 0.222651 | 0.025952 |
AIRLOOP F4 S2 OA CONTROLLER | 0.223639 | 0.025952 |
AIRLOOP M SW OA CONTROLLER | 0.350310 | 0.025952 |
AIRLOOP M NW OA CONTROLLER | 0.320861 | 0.025952 |
AIRLOOP M SE OA CONTROLLER | 0.317028 | 0.025952 |
AIRLOOP M NE OA CONTROLLER | 0.251089 | 0.025952 |
AIRLOOP M N1 OA CONTROLLER | 0.169545 | 0.025952 |
AIRLOOP M N2 OA CONTROLLER | 0.167992 | 0.025952 |
AIRLOOP M S1 OA CONTROLLER | 0.226969 | 0.025952 |
AIRLOOP M S2 OA CONTROLLER | 0.227929 | 0.025952 |
AIRLOOP F6 SW OA CONTROLLER | 0.348302 | 0.025952 |
AIRLOOP F6 NW OA CONTROLLER | 0.318735 | 0.025952 |
AIRLOOP F6 SE OA CONTROLLER | 0.315863 | 0.025952 |
AIRLOOP F6 NE OA CONTROLLER | 0.249205 | 0.025952 |
AIRLOOP F6 N1 OA CONTROLLER | 0.167288 | 0.025952 |
AIRLOOP F6 N2 OA CONTROLLER | 0.165746 | 0.025952 |
AIRLOOP F6 S1 OA CONTROLLER | 0.225085 | 0.025952 |
AIRLOOP F6 S2 OA CONTROLLER | 0.226041 | 0.025952 |
AIRLOOP F7 SW OA CONTROLLER | 0.348372 | 0.025952 |
AIRLOOP F7 NW OA CONTROLLER | 0.318782 | 0.025952 |
AIRLOOP F7 SE OA CONTROLLER | 0.316679 | 0.025952 |
AIRLOOP F7 NE OA CONTROLLER | 0.249425 | 0.025952 |
AIRLOOP F7 N1 OA CONTROLLER | 0.167115 | 0.025952 |
AIRLOOP F7 N2 OA CONTROLLER | 0.165581 | 0.025952 |
AIRLOOP F7 S1 OA CONTROLLER | 0.225227 | 0.025952 |
AIRLOOP F7 S2 OA CONTROLLER | 0.226182 | 0.025952 |
AIRLOOP F8 SW OA CONTROLLER | 0.349698 | 0.025952 |
AIRLOOP F8 NW OA CONTROLLER | 0.320098 | 0.025952 |
AIRLOOP F8 SE OA CONTROLLER | 0.318580 | 0.025952 |
AIRLOOP F8 NE OA CONTROLLER | 0.250791 | 0.025952 |
AIRLOOP F8 N1 OA CONTROLLER | 0.168238 | 0.025952 |
AIRLOOP F8 N2 OA CONTROLLER | 0.166714 | 0.025952 |
AIRLOOP F8 S1 OA CONTROLLER | 0.226545 | 0.025952 |
AIRLOOP F8 S2 OA CONTROLLER | 0.227502 | 0.025952 |
AIRLOOP F9 SW OA CONTROLLER | 0.361483 | 0.025952 |
AIRLOOP F9 NW OA CONTROLLER | 0.331466 | 0.025952 |
AIRLOOP F9 SE OA CONTROLLER | 0.327754 | 0.025952 |
AIRLOOP F9 NE OA CONTROLLER | 0.255699 | 0.025952 |
AIRLOOP F9 N1 OA CONTROLLER | 0.178010 | 0.025952 |
AIRLOOP F9 N2 OA CONTROLLER | 0.176478 | 0.025952 |
AIRLOOP F9 S1 OA CONTROLLER | 0.234054 | 0.025952 |
AIRLOOP F9 S2 OA CONTROLLER | 0.235107 | 0.025952 |
AIRLOOP T SW OA CONTROLLER | 0.446752 | 0.025952 |
AIRLOOP T NW OA CONTROLLER | 0.405202 | 0.025952 |
AIRLOOP T SE OA CONTROLLER | 0.409650 | 0.025952 |
AIRLOOP T NE OA CONTROLLER | 0.319637 | 0.025952 |
AIRLOOP T N1 OA CONTROLLER | 0.240293 | 0.025952 |
AIRLOOP T N2 OA CONTROLLER | 0.240115 | 0.025952 |
AIRLOOP T S1 OA CONTROLLER | 0.326633 | 0.025952 |
AIRLOOP T S2 OA CONTROLLER | 0.327472 | 0.025952 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity [W] | Rated Sensible Cooling Capacity [W] | Rated Water Flow Rate [m3/s] | |
HEAT PUMP COOLING MODE AIRLOOP G SW | 0.266307 | 3596.54 | 2587.54 | 0.000079 |
HEAT PUMP COOLING MODE AIRLOOP G NW | 0.245974 | 3307.90 | 2383.07 | 0.000072 |
HEAT PUMP COOLING MODE AIRLOOP OFFICE | 0.385195 | 5345.85 | 3810.25 | 0.000117 |
HEAT PUMP COOLING MODE AIRLOOP G NE | 0.178831 | 2432.32 | 1758.73 | 0.000053 |
HEAT PUMP COOLING MODE AIRLOOP G N1 | 0.120314 | 1637.65 | 1184.05 | 0.000036 |
HEAT PUMP COOLING MODE AIRLOOP G N2 | 0.118360 | 1611.58 | 1165.49 | 0.000035 |
HEAT PUMP COOLING MODE AIRLOOP G S1 | 0.164237 | 2368.79 | 1669.08 | 0.000052 |
HEAT PUMP COOLING MODE AIRLOOP G S2 | 0.170995 | 2458.09 | 1733.38 | 0.000054 |
HEAT PUMP COOLING MODE AIRLOOP F2 SW | 0.340752 | 4552.52 | 3285.58 | 0.000099 |
HEAT PUMP COOLING MODE AIRLOOP F2 NW | 0.310262 | 4131.93 | 2985.45 | 0.000090 |
HEAT PUMP COOLING MODE AIRLOOP F2 SE | 0.327454 | 4472.48 | 3205.42 | 0.000098 |
HEAT PUMP COOLING MODE AIRLOOP F2 NE | 0.238457 | 3191.48 | 2317.14 | 0.000070 |
HEAT PUMP COOLING MODE AIRLOOP F2 N1 | 0.159432 | 2144.05 | 1552.22 | 0.000047 |
HEAT PUMP COOLING MODE AIRLOOP F2 N2 | 0.157864 | 2123.24 | 1537.37 | 0.000046 |
HEAT PUMP COOLING MODE AIRLOOP F2 S1 | 0.214707 | 3019.75 | 2145.15 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP F2 S2 | 0.217214 | 3052.86 | 2168.94 | 0.000067 |
HEAT PUMP COOLING MODE AIRLOOP F3 SW | 0.343432 | 4581.89 | 3312.29 | 0.000100 |
HEAT PUMP COOLING MODE AIRLOOP F3 NW | 0.313937 | 4168.90 | 3021.74 | 0.000091 |
HEAT PUMP COOLING MODE AIRLOOP F3 SE | 0.310405 | 4232.16 | 3040.79 | 0.000092 |
HEAT PUMP COOLING MODE AIRLOOP F3 NE | 0.243881 | 3247.74 | 2365.18 | 0.000071 |
HEAT PUMP COOLING MODE AIRLOOP F3 N1 | 0.163563 | 2189.90 | 1589.45 | 0.000048 |
HEAT PUMP COOLING MODE AIRLOOP F3 N2 | 0.162001 | 2169.19 | 1574.65 | 0.000047 |
HEAT PUMP COOLING MODE AIRLOOP F3 S1 | 0.219865 | 3078.57 | 2192.08 | 0.000067 |
HEAT PUMP COOLING MODE AIRLOOP F3 S2 | 0.221042 | 3094.11 | 2203.24 | 0.000068 |
HEAT PUMP COOLING MODE AIRLOOP F4 SW | 0.346018 | 4603.95 | 3334.15 | 0.000101 |
HEAT PUMP COOLING MODE AIRLOOP F4 NW | 0.316536 | 4191.21 | 3043.74 | 0.000092 |
HEAT PUMP COOLING MODE AIRLOOP F4 SE | 0.312031 | 4241.97 | 3053.68 | 0.000093 |
HEAT PUMP COOLING MODE AIRLOOP F4 NE | 0.246639 | 3285.06 | 2394.05 | 0.000072 |
HEAT PUMP COOLING MODE AIRLOOP F4 N1 | 0.165741 | 2212.07 | 1608.64 | 0.000048 |
HEAT PUMP COOLING MODE AIRLOOP F4 N2 | 0.164183 | 2191.45 | 1593.89 | 0.000048 |
HEAT PUMP COOLING MODE AIRLOOP F4 S1 | 0.222651 | 3108.37 | 2216.99 | 0.000068 |
HEAT PUMP COOLING MODE AIRLOOP F4 S2 | 0.223639 | 3121.41 | 2226.36 | 0.000068 |
HEAT PUMP COOLING MODE AIRLOOP M SW | 0.350310 | 4650.74 | 3372.60 | 0.000102 |
HEAT PUMP COOLING MODE AIRLOOP M NW | 0.320861 | 4238.51 | 3082.52 | 0.000093 |
HEAT PUMP COOLING MODE AIRLOOP M SE | 0.317028 | 4298.30 | 3098.90 | 0.000094 |
HEAT PUMP COOLING MODE AIRLOOP M NE | 0.251089 | 3334.45 | 2434.15 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP M N1 | 0.169545 | 2257.05 | 1643.51 | 0.000049 |
HEAT PUMP COOLING MODE AIRLOOP M N2 | 0.167992 | 2236.50 | 1628.81 | 0.000049 |
HEAT PUMP COOLING MODE AIRLOOP M S1 | 0.226969 | 3159.62 | 2256.70 | 0.000069 |
HEAT PUMP COOLING MODE AIRLOOP M S2 | 0.227929 | 3172.29 | 2265.80 | 0.000069 |
HEAT PUMP COOLING MODE AIRLOOP F6 SW | 0.348302 | 4615.94 | 3351.85 | 0.000101 |
HEAT PUMP COOLING MODE AIRLOOP F6 NW | 0.318735 | 4202.20 | 3060.66 | 0.000092 |
HEAT PUMP COOLING MODE AIRLOOP F6 SE | 0.315863 | 4274.97 | 3086.17 | 0.000093 |
HEAT PUMP COOLING MODE AIRLOOP F6 NE | 0.249205 | 3302.10 | 2414.75 | 0.000072 |
HEAT PUMP COOLING MODE AIRLOOP F6 N1 | 0.167288 | 2222.52 | 1621.16 | 0.000049 |
HEAT PUMP COOLING MODE AIRLOOP F6 N2 | 0.165746 | 2202.14 | 1606.57 | 0.000048 |
HEAT PUMP COOLING MODE AIRLOOP F6 S1 | 0.225085 | 3130.01 | 2237.82 | 0.000068 |
HEAT PUMP COOLING MODE AIRLOOP F6 S2 | 0.226041 | 3142.63 | 2246.88 | 0.000069 |
HEAT PUMP COOLING MODE AIRLOOP F7 SW | 0.348372 | 4609.57 | 3350.95 | 0.000101 |
HEAT PUMP COOLING MODE AIRLOOP F7 NW | 0.318782 | 4195.59 | 3059.57 | 0.000092 |
HEAT PUMP COOLING MODE AIRLOOP F7 SE | 0.316679 | 4278.69 | 3092.38 | 0.000093 |
HEAT PUMP COOLING MODE AIRLOOP F7 NE | 0.249425 | 3298.33 | 2415.42 | 0.000072 |
HEAT PUMP COOLING MODE AIRLOOP F7 N1 | 0.167115 | 2216.20 | 1618.67 | 0.000048 |
HEAT PUMP COOLING MODE AIRLOOP F7 N2 | 0.165581 | 2195.95 | 1604.16 | 0.000048 |
HEAT PUMP COOLING MODE AIRLOOP F7 S1 | 0.225227 | 3127.68 | 2238.26 | 0.000068 |
HEAT PUMP COOLING MODE AIRLOOP F7 S2 | 0.226182 | 3140.28 | 2247.31 | 0.000069 |
HEAT PUMP COOLING MODE AIRLOOP F8 SW | 0.349698 | 4620.51 | 3362.08 | 0.000101 |
HEAT PUMP COOLING MODE AIRLOOP F8 NW | 0.320098 | 4206.46 | 3070.62 | 0.000092 |
HEAT PUMP COOLING MODE AIRLOOP F8 SE | 0.318580 | 4297.40 | 3109.01 | 0.000094 |
HEAT PUMP COOLING MODE AIRLOOP F8 NE | 0.250791 | 3310.28 | 2427.05 | 0.000072 |
HEAT PUMP COOLING MODE AIRLOOP F8 N1 | 0.168238 | 2227.45 | 1628.52 | 0.000049 |
HEAT PUMP COOLING MODE AIRLOOP F8 N2 | 0.166714 | 2207.34 | 1614.11 | 0.000048 |
HEAT PUMP COOLING MODE AIRLOOP F8 S1 | 0.226545 | 3141.27 | 2249.94 | 0.000069 |
HEAT PUMP COOLING MODE AIRLOOP F8 S2 | 0.227502 | 3153.89 | 2259.01 | 0.000069 |
HEAT PUMP COOLING MODE AIRLOOP F9 SW | 0.361483 | 4769.64 | 3472.09 | 0.000104 |
HEAT PUMP COOLING MODE AIRLOOP F9 NW | 0.331466 | 4350.19 | 3176.71 | 0.000095 |
HEAT PUMP COOLING MODE AIRLOOP F9 SE | 0.327754 | 4412.41 | 3194.52 | 0.000096 |
HEAT PUMP COOLING MODE AIRLOOP F9 NE | 0.255699 | 3369.06 | 2472.21 | 0.000074 |
HEAT PUMP COOLING MODE AIRLOOP F9 N1 | 0.178010 | 2353.31 | 1720.28 | 0.000051 |
HEAT PUMP COOLING MODE AIRLOOP F9 N2 | 0.176478 | 2333.10 | 1705.79 | 0.000051 |
HEAT PUMP COOLING MODE AIRLOOP F9 S1 | 0.234054 | 3236.76 | 2320.35 | 0.000071 |
HEAT PUMP COOLING MODE AIRLOOP F9 S2 | 0.235107 | 3250.41 | 2330.28 | 0.000071 |
HEAT PUMP COOLING MODE AIRLOOP T SW | 0.446752 | 5933.42 | 4300.71 | 0.000130 |
HEAT PUMP COOLING MODE AIRLOOP T NW | 0.405202 | 5349.33 | 3888.52 | 0.000117 |
HEAT PUMP COOLING MODE AIRLOOP T SE | 0.409650 | 5483.46 | 3966.99 | 0.000120 |
HEAT PUMP COOLING MODE AIRLOOP T NE | 0.319637 | 4300.51 | 3116.70 | 0.000094 |
HEAT PUMP COOLING MODE AIRLOOP T N1 | 0.240293 | 3301.70 | 2372.87 | 0.000072 |
HEAT PUMP COOLING MODE AIRLOOP T N2 | 0.240115 | 3306.27 | 2374.11 | 0.000072 |
HEAT PUMP COOLING MODE AIRLOOP T S1 | 0.326633 | 4452.28 | 3195.64 | 0.000097 |
HEAT PUMP COOLING MODE AIRLOOP T S2 | 0.327472 | 4463.37 | 3203.58 | 0.000098 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Supplemental Heating Coil Nominal Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
AIRLOOP G SW DXAC HEAT PUMP | 0.266307 | 0.266307 | 0.266307 | 0.266307 | 3596.54 | 3596.54 | 3760.47 | 1.00 |
AIRLOOP G NW DXAC HEAT PUMP | 0.245974 | 0.245974 | 0.245974 | 0.245974 | 3307.90 | 3307.90 | 3775.08 | 1.00 |
AIRLOOP OFFICE DXAC HEAT PUMP | 0.385195 | 0.385195 | 0.385195 | 0.385195 | 5345.85 | 5345.85 | 4652.81 | 1.00 |
AIRLOOP G NE DXAC HEAT PUMP | 0.178831 | 0.178831 | 0.178831 | 0.178831 | 2432.32 | 2432.32 | 3770.34 | 1.00 |
AIRLOOP G N1 DXAC HEAT PUMP | 0.120314 | 0.120314 | 0.120314 | 0.120314 | 1637.65 | 1637.65 | 2902.28 | 1.00 |
AIRLOOP G N2 DXAC HEAT PUMP | 0.118360 | 0.118360 | 0.118360 | 0.118360 | 1611.58 | 1611.58 | 2902.17 | 1.00 |
AIRLOOP G S1 DXAC HEAT PUMP | 0.164237 | 0.164237 | 0.164237 | 0.164237 | 2368.79 | 2368.79 | 2884.58 | 1.00 |
AIRLOOP G S2 DXAC HEAT PUMP | 0.170995 | 0.170995 | 0.170995 | 0.170995 | 2458.09 | 2458.09 | 2890.75 | 1.00 |
AIRLOOP F2 SW DXAC HEAT PUMP | 0.340752 | 0.340752 | 0.340752 | 0.340752 | 4552.52 | 4552.52 | 3613.42 | 1.00 |
AIRLOOP F2 NW DXAC HEAT PUMP | 0.310262 | 0.310262 | 0.310262 | 0.310262 | 4131.93 | 4131.93 | 3620.19 | 1.00 |
AIRLOOP F2 SE DXAC HEAT PUMP | 0.327454 | 0.327454 | 0.327454 | 0.327454 | 4472.48 | 4472.48 | 3627.05 | 1.00 |
AIRLOOP F2 NE DXAC HEAT PUMP | 0.238457 | 0.238457 | 0.238457 | 0.238457 | 3191.48 | 3191.48 | 3615.49 | 1.00 |
AIRLOOP F2 N1 DXAC HEAT PUMP | 0.159432 | 0.159432 | 0.159432 | 0.159432 | 2144.05 | 2144.05 | 2552.26 | 1.00 |
AIRLOOP F2 N2 DXAC HEAT PUMP | 0.157864 | 0.157864 | 0.157864 | 0.157864 | 2123.24 | 2123.24 | 2552.15 | 1.00 |
AIRLOOP F2 S1 DXAC HEAT PUMP | 0.214707 | 0.214707 | 0.214707 | 0.214707 | 3019.75 | 3019.75 | 2548.35 | 1.00 |
AIRLOOP F2 S2 DXAC HEAT PUMP | 0.217214 | 0.217214 | 0.217214 | 0.217214 | 3052.86 | 3052.86 | 2549.39 | 1.00 |
AIRLOOP F3 SW DXAC HEAT PUMP | 0.343432 | 0.343432 | 0.343432 | 0.343432 | 4581.89 | 4581.89 | 3612.74 | 1.00 |
AIRLOOP F3 NW DXAC HEAT PUMP | 0.313937 | 0.313937 | 0.313937 | 0.313937 | 4168.90 | 4168.90 | 3619.74 | 1.00 |
AIRLOOP F3 SE DXAC HEAT PUMP | 0.310405 | 0.310405 | 0.310405 | 0.310405 | 4232.16 | 4232.16 | 3610.92 | 1.00 |
AIRLOOP F3 NE DXAC HEAT PUMP | 0.243881 | 0.243881 | 0.243881 | 0.243881 | 3247.74 | 3247.74 | 3615.99 | 1.00 |
AIRLOOP F3 N1 DXAC HEAT PUMP | 0.163563 | 0.163563 | 0.163563 | 0.163563 | 2189.90 | 2189.90 | 2505.97 | 1.00 |
AIRLOOP F3 N2 DXAC HEAT PUMP | 0.162001 | 0.162001 | 0.162001 | 0.162001 | 2169.19 | 2169.19 | 2505.88 | 1.00 |
AIRLOOP F3 S1 DXAC HEAT PUMP | 0.219865 | 0.219865 | 0.219865 | 0.219865 | 3078.57 | 3078.57 | 2499.87 | 1.00 |
AIRLOOP F3 S2 DXAC HEAT PUMP | 0.221042 | 0.221042 | 0.221042 | 0.221042 | 3094.11 | 3094.11 | 2499.96 | 1.00 |
AIRLOOP F4 SW DXAC HEAT PUMP | 0.346018 | 0.346018 | 0.346018 | 0.346018 | 4603.95 | 4603.95 | 3678.92 | 1.00 |
AIRLOOP F4 NW DXAC HEAT PUMP | 0.316536 | 0.316536 | 0.316536 | 0.316536 | 4191.21 | 4191.21 | 3685.23 | 1.00 |
AIRLOOP F4 SE DXAC HEAT PUMP | 0.312031 | 0.312031 | 0.312031 | 0.312031 | 4241.97 | 4241.97 | 3676.25 | 1.00 |
AIRLOOP F4 NE DXAC HEAT PUMP | 0.246639 | 0.246639 | 0.246639 | 0.246639 | 3285.06 | 3285.06 | 3682.36 | 1.00 |
AIRLOOP F4 N1 DXAC HEAT PUMP | 0.165741 | 0.165741 | 0.165741 | 0.165741 | 2212.07 | 2212.07 | 2533.67 | 1.00 |
AIRLOOP F4 N2 DXAC HEAT PUMP | 0.164183 | 0.164183 | 0.164183 | 0.164183 | 2191.45 | 2191.45 | 2533.60 | 1.00 |
AIRLOOP F4 S1 DXAC HEAT PUMP | 0.222651 | 0.222651 | 0.222651 | 0.222651 | 3108.37 | 3108.37 | 2527.99 | 1.00 |
AIRLOOP F4 S2 DXAC HEAT PUMP | 0.223639 | 0.223639 | 0.223639 | 0.223639 | 3121.41 | 3121.41 | 2527.95 | 1.00 |
AIRLOOP M SW DXAC HEAT PUMP | 0.350310 | 0.350310 | 0.350310 | 0.350310 | 4650.74 | 4650.74 | 3724.22 | 1.00 |
AIRLOOP M NW DXAC HEAT PUMP | 0.320861 | 0.320861 | 0.320861 | 0.320861 | 4238.51 | 4238.51 | 3728.46 | 1.00 |
AIRLOOP M SE DXAC HEAT PUMP | 0.317028 | 0.317028 | 0.317028 | 0.317028 | 4298.30 | 4298.30 | 3722.17 | 1.00 |
AIRLOOP M NE DXAC HEAT PUMP | 0.251089 | 0.251089 | 0.251089 | 0.251089 | 3334.45 | 3334.45 | 3726.39 | 1.00 |
AIRLOOP M N1 DXAC HEAT PUMP | 0.169545 | 0.169545 | 0.169545 | 0.169545 | 2257.05 | 2257.05 | 2546.94 | 1.00 |
AIRLOOP M N2 DXAC HEAT PUMP | 0.167992 | 0.167992 | 0.167992 | 0.167992 | 2236.50 | 2236.50 | 2546.89 | 1.00 |
AIRLOOP M S1 DXAC HEAT PUMP | 0.226969 | 0.226969 | 0.226969 | 0.226969 | 3159.62 | 3159.62 | 2543.31 | 1.00 |
AIRLOOP M S2 DXAC HEAT PUMP | 0.227929 | 0.227929 | 0.227929 | 0.227929 | 3172.29 | 3172.29 | 2543.26 | 1.00 |
AIRLOOP F6 SW DXAC HEAT PUMP | 0.348302 | 0.348302 | 0.348302 | 0.348302 | 4615.94 | 4615.94 | 3825.60 | 1.00 |
AIRLOOP F6 NW DXAC HEAT PUMP | 0.318735 | 0.318735 | 0.318735 | 0.318735 | 4202.20 | 4202.20 | 3829.61 | 1.00 |
AIRLOOP F6 SE DXAC HEAT PUMP | 0.315863 | 0.315863 | 0.315863 | 0.315863 | 4274.97 | 4274.97 | 3824.25 | 1.00 |
AIRLOOP F6 NE DXAC HEAT PUMP | 0.249205 | 0.249205 | 0.249205 | 0.249205 | 3302.10 | 3302.10 | 3828.26 | 1.00 |
AIRLOOP F6 N1 DXAC HEAT PUMP | 0.167288 | 0.167288 | 0.167288 | 0.167288 | 2222.52 | 2222.52 | 2621.07 | 1.00 |
AIRLOOP F6 N2 DXAC HEAT PUMP | 0.165746 | 0.165746 | 0.165746 | 0.165746 | 2202.14 | 2202.14 | 2621.04 | 1.00 |
AIRLOOP F6 S1 DXAC HEAT PUMP | 0.225085 | 0.225085 | 0.225085 | 0.225085 | 3130.01 | 3130.01 | 2617.65 | 1.00 |
AIRLOOP F6 S2 DXAC HEAT PUMP | 0.226041 | 0.226041 | 0.226041 | 0.226041 | 3142.63 | 3142.63 | 2617.62 | 1.00 |
AIRLOOP F7 SW DXAC HEAT PUMP | 0.348372 | 0.348372 | 0.348372 | 0.348372 | 4609.57 | 4609.57 | 3898.88 | 1.00 |
AIRLOOP F7 NW DXAC HEAT PUMP | 0.318782 | 0.318782 | 0.318782 | 0.318782 | 4195.59 | 4195.59 | 3901.65 | 1.00 |
AIRLOOP F7 SE DXAC HEAT PUMP | 0.316679 | 0.316679 | 0.316679 | 0.316679 | 4278.69 | 4278.69 | 3898.18 | 1.00 |
AIRLOOP F7 NE DXAC HEAT PUMP | 0.249425 | 0.249425 | 0.249425 | 0.249425 | 3298.33 | 3298.33 | 3900.95 | 1.00 |
AIRLOOP F7 N1 DXAC HEAT PUMP | 0.167115 | 0.167115 | 0.167115 | 0.167115 | 2216.20 | 2216.20 | 2670.23 | 1.00 |
AIRLOOP F7 N2 DXAC HEAT PUMP | 0.165581 | 0.165581 | 0.165581 | 0.165581 | 2195.95 | 2195.95 | 2670.21 | 1.00 |
AIRLOOP F7 S1 DXAC HEAT PUMP | 0.225227 | 0.225227 | 0.225227 | 0.225227 | 3127.68 | 3127.68 | 2668.08 | 1.00 |
AIRLOOP F7 S2 DXAC HEAT PUMP | 0.226182 | 0.226182 | 0.226182 | 0.226182 | 3140.28 | 3140.28 | 2668.06 | 1.00 |
AIRLOOP F8 SW DXAC HEAT PUMP | 0.349698 | 0.349698 | 0.349698 | 0.349698 | 4620.51 | 4620.51 | 3977.43 | 1.00 |
AIRLOOP F8 NW DXAC HEAT PUMP | 0.320098 | 0.320098 | 0.320098 | 0.320098 | 4206.46 | 4206.46 | 3978.75 | 1.00 |
AIRLOOP F8 SE DXAC HEAT PUMP | 0.318580 | 0.318580 | 0.318580 | 0.318580 | 4297.40 | 4297.40 | 3977.33 | 1.00 |
AIRLOOP F8 NE DXAC HEAT PUMP | 0.250791 | 0.250791 | 0.250791 | 0.250791 | 3310.28 | 3310.28 | 3978.65 | 1.00 |
AIRLOOP F8 N1 DXAC HEAT PUMP | 0.168238 | 0.168238 | 0.168238 | 0.168238 | 2227.45 | 2227.45 | 2727.07 | 1.00 |
AIRLOOP F8 N2 DXAC HEAT PUMP | 0.166714 | 0.166714 | 0.166714 | 0.166714 | 2207.34 | 2207.34 | 2727.06 | 1.00 |
AIRLOOP F8 S1 DXAC HEAT PUMP | 0.226545 | 0.226545 | 0.226545 | 0.226545 | 3141.27 | 3141.27 | 2726.37 | 1.00 |
AIRLOOP F8 S2 DXAC HEAT PUMP | 0.227502 | 0.227502 | 0.227502 | 0.227502 | 3153.89 | 3153.89 | 2726.37 | 1.00 |
AIRLOOP F9 SW DXAC HEAT PUMP | 0.361483 | 0.361483 | 0.361483 | 0.361483 | 4769.64 | 4769.64 | 4203.83 | 1.00 |
AIRLOOP F9 NW DXAC HEAT PUMP | 0.331466 | 0.331466 | 0.331466 | 0.331466 | 4350.19 | 4350.19 | 4200.93 | 1.00 |
AIRLOOP F9 SE DXAC HEAT PUMP | 0.327754 | 0.327754 | 0.327754 | 0.327754 | 4412.41 | 4412.41 | 4204.28 | 1.00 |
AIRLOOP F9 NE DXAC HEAT PUMP | 0.255699 | 0.255699 | 0.255699 | 0.255699 | 3369.06 | 3369.06 | 4201.39 | 1.00 |
AIRLOOP F9 N1 DXAC HEAT PUMP | 0.178010 | 0.178010 | 0.178010 | 0.178010 | 2353.31 | 2353.31 | 2921.24 | 1.00 |
AIRLOOP F9 N2 DXAC HEAT PUMP | 0.176478 | 0.176478 | 0.176478 | 0.176478 | 2333.10 | 2333.10 | 2921.25 | 1.00 |
AIRLOOP F9 S1 DXAC HEAT PUMP | 0.234054 | 0.234054 | 0.234054 | 0.234054 | 3236.76 | 3236.76 | 2924.33 | 1.00 |
AIRLOOP F9 S2 DXAC HEAT PUMP | 0.235107 | 0.235107 | 0.235107 | 0.235107 | 3250.41 | 3250.41 | 2924.34 | 1.00 |
AIRLOOP T SW DXAC HEAT PUMP | 0.446752 | 0.446752 | 0.446752 | 0.446752 | 5933.42 | 5933.42 | 4999.34 | 1.00 |
AIRLOOP T NW DXAC HEAT PUMP | 0.405202 | 0.405202 | 0.405202 | 0.405202 | 5349.33 | 5349.33 | 5003.61 | 1.00 |
AIRLOOP T SE DXAC HEAT PUMP | 0.409650 | 0.409650 | 0.409650 | 0.409650 | 5483.46 | 5483.46 | 5000.21 | 1.00 |
AIRLOOP T NE DXAC HEAT PUMP | 0.319637 | 0.319637 | 0.319637 | 0.319637 | 4300.51 | 4300.51 | 5004.47 | 1.00 |
AIRLOOP T N1 DXAC HEAT PUMP | 0.240293 | 0.240293 | 0.240293 | 0.240293 | 3301.70 | 3301.70 | 3771.06 | 1.00 |
AIRLOOP T N2 DXAC HEAT PUMP | 0.240115 | 0.240115 | 0.240115 | 0.240115 | 3306.27 | 3306.27 | 3771.08 | 1.00 |
AIRLOOP T S1 DXAC HEAT PUMP | 0.326633 | 0.326633 | 0.326633 | 0.326633 | 4452.28 | 4452.28 | 3764.02 | 1.00 |
AIRLOOP T S2 DXAC HEAT PUMP | 0.327472 | 0.327472 | 0.327472 | 0.327472 | 4463.37 | 4463.37 | 3764.04 | 1.00 |
Maximum Flow Rate [m3/s] | |
AIRLOOP G SW SUPPLY FAN | 0.266307 |
AIRLOOP G NW SUPPLY FAN | 0.245974 |
AIRLOOP OFFICE SUPPLY FAN | 0.385195 |
AIRLOOP G NE SUPPLY FAN | 0.178831 |
AIRLOOP G N1 SUPPLY FAN | 0.120314 |
AIRLOOP G N2 SUPPLY FAN | 0.118360 |
AIRLOOP G S1 SUPPLY FAN | 0.164237 |
AIRLOOP G S2 SUPPLY FAN | 0.170995 |
AIRLOOP F2 SW SUPPLY FAN | 0.340752 |
AIRLOOP F2 NW SUPPLY FAN | 0.310262 |
AIRLOOP F2 SE SUPPLY FAN | 0.327454 |
AIRLOOP F2 NE SUPPLY FAN | 0.238457 |
AIRLOOP F2 N1 SUPPLY FAN | 0.159432 |
AIRLOOP F2 N2 SUPPLY FAN | 0.157864 |
AIRLOOP F2 S1 SUPPLY FAN | 0.214707 |
AIRLOOP F2 S2 SUPPLY FAN | 0.217214 |
AIRLOOP F3 SW SUPPLY FAN | 0.343432 |
AIRLOOP F3 NW SUPPLY FAN | 0.313937 |
AIRLOOP F3 SE SUPPLY FAN | 0.310405 |
AIRLOOP F3 NE SUPPLY FAN | 0.243881 |
AIRLOOP F3 N1 SUPPLY FAN | 0.163563 |
AIRLOOP F3 N2 SUPPLY FAN | 0.162001 |
AIRLOOP F3 S1 SUPPLY FAN | 0.219865 |
AIRLOOP F3 S2 SUPPLY FAN | 0.221042 |
AIRLOOP F4 SW SUPPLY FAN | 0.346018 |
AIRLOOP F4 NW SUPPLY FAN | 0.316536 |
AIRLOOP F4 SE SUPPLY FAN | 0.312031 |
AIRLOOP F4 NE SUPPLY FAN | 0.246639 |
AIRLOOP F4 N1 SUPPLY FAN | 0.165741 |
AIRLOOP F4 N2 SUPPLY FAN | 0.164183 |
AIRLOOP F4 S1 SUPPLY FAN | 0.222651 |
AIRLOOP F4 S2 SUPPLY FAN | 0.223639 |
AIRLOOP M SW SUPPLY FAN | 0.350310 |
AIRLOOP M NW SUPPLY FAN | 0.320861 |
AIRLOOP M SE SUPPLY FAN | 0.317028 |
AIRLOOP M NE SUPPLY FAN | 0.251089 |
AIRLOOP M N1 SUPPLY FAN | 0.169545 |
AIRLOOP M N2 SUPPLY FAN | 0.167992 |
AIRLOOP M S1 SUPPLY FAN | 0.226969 |
AIRLOOP M S2 SUPPLY FAN | 0.227929 |
AIRLOOP F6 SW SUPPLY FAN | 0.348302 |
AIRLOOP F6 NW SUPPLY FAN | 0.318735 |
AIRLOOP F6 SE SUPPLY FAN | 0.315863 |
AIRLOOP F6 NE SUPPLY FAN | 0.249205 |
AIRLOOP F6 N1 SUPPLY FAN | 0.167288 |
AIRLOOP F6 N2 SUPPLY FAN | 0.165746 |
AIRLOOP F6 S1 SUPPLY FAN | 0.225085 |
AIRLOOP F6 S2 SUPPLY FAN | 0.226041 |
AIRLOOP F7 SW SUPPLY FAN | 0.348372 |
AIRLOOP F7 NW SUPPLY FAN | 0.318782 |
AIRLOOP F7 SE SUPPLY FAN | 0.316679 |
AIRLOOP F7 NE SUPPLY FAN | 0.249425 |
AIRLOOP F7 N1 SUPPLY FAN | 0.167115 |
AIRLOOP F7 N2 SUPPLY FAN | 0.165581 |
AIRLOOP F7 S1 SUPPLY FAN | 0.225227 |
AIRLOOP F7 S2 SUPPLY FAN | 0.226182 |
AIRLOOP F8 SW SUPPLY FAN | 0.349698 |
AIRLOOP F8 NW SUPPLY FAN | 0.320098 |
AIRLOOP F8 SE SUPPLY FAN | 0.318580 |
AIRLOOP F8 NE SUPPLY FAN | 0.250791 |
AIRLOOP F8 N1 SUPPLY FAN | 0.168238 |
AIRLOOP F8 N2 SUPPLY FAN | 0.166714 |
AIRLOOP F8 S1 SUPPLY FAN | 0.226545 |
AIRLOOP F8 S2 SUPPLY FAN | 0.227502 |
AIRLOOP F9 SW SUPPLY FAN | 0.361483 |
AIRLOOP F9 NW SUPPLY FAN | 0.331466 |
AIRLOOP F9 SE SUPPLY FAN | 0.327754 |
AIRLOOP F9 NE SUPPLY FAN | 0.255699 |
AIRLOOP F9 N1 SUPPLY FAN | 0.178010 |
AIRLOOP F9 N2 SUPPLY FAN | 0.176478 |
AIRLOOP F9 S1 SUPPLY FAN | 0.234054 |
AIRLOOP F9 S2 SUPPLY FAN | 0.235107 |
AIRLOOP T SW SUPPLY FAN | 0.446752 |
AIRLOOP T NW SUPPLY FAN | 0.405202 |
AIRLOOP T SE SUPPLY FAN | 0.409650 |
AIRLOOP T NE SUPPLY FAN | 0.319637 |
AIRLOOP T N1 SUPPLY FAN | 0.240293 |
AIRLOOP T N2 SUPPLY FAN | 0.240115 |
AIRLOOP T S1 SUPPLY FAN | 0.326633 |
AIRLOOP T S2 SUPPLY FAN | 0.327472 |
Rated Air Flow Rate [m3/s] | Rated Heating Capacity [W] | Rated Water Flow Rate [m3/s] | |
HEAT PUMP HEATING MODE AIRLOOP G SW | 0.266307 | 3596.54 | 0.000079 |
HEAT PUMP HEATING MODE AIRLOOP G NW | 0.245974 | 3307.90 | 0.000072 |
HEAT PUMP HEATING MODE AIRLOOP OFFICE | 0.385195 | 5345.85 | 0.000117 |
HEAT PUMP HEATING MODE AIRLOOP G NE | 0.178831 | 2432.32 | 0.000053 |
HEAT PUMP HEATING MODE AIRLOOP G N1 | 0.120314 | 1637.65 | 0.000036 |
HEAT PUMP HEATING MODE AIRLOOP G N2 | 0.118360 | 1611.58 | 0.000035 |
HEAT PUMP HEATING MODE AIRLOOP G S1 | 0.164237 | 2368.79 | 0.000052 |
HEAT PUMP HEATING MODE AIRLOOP G S2 | 0.170995 | 2458.09 | 0.000054 |
HEAT PUMP HEATING MODE AIRLOOP F2 SW | 0.340752 | 4552.52 | 0.000099 |
HEAT PUMP HEATING MODE AIRLOOP F2 NW | 0.310262 | 4131.93 | 0.000090 |
HEAT PUMP HEATING MODE AIRLOOP F2 SE | 0.327454 | 4472.48 | 0.000098 |
HEAT PUMP HEATING MODE AIRLOOP F2 NE | 0.238457 | 3191.48 | 0.000070 |
HEAT PUMP HEATING MODE AIRLOOP F2 N1 | 0.159432 | 2144.05 | 0.000047 |
HEAT PUMP HEATING MODE AIRLOOP F2 N2 | 0.157864 | 2123.24 | 0.000046 |
HEAT PUMP HEATING MODE AIRLOOP F2 S1 | 0.214707 | 3019.75 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP F2 S2 | 0.217214 | 3052.86 | 0.000067 |
HEAT PUMP HEATING MODE AIRLOOP F3 SW | 0.343432 | 4581.89 | 0.000100 |
HEAT PUMP HEATING MODE AIRLOOP F3 NW | 0.313937 | 4168.90 | 0.000091 |
HEAT PUMP HEATING MODE AIRLOOP F3 SE | 0.310405 | 4232.16 | 0.000092 |
HEAT PUMP HEATING MODE AIRLOOP F3 NE | 0.243881 | 3247.74 | 0.000071 |
HEAT PUMP HEATING MODE AIRLOOP F3 N1 | 0.163563 | 2189.90 | 0.000048 |
HEAT PUMP HEATING MODE AIRLOOP F3 N2 | 0.162001 | 2169.19 | 0.000047 |
HEAT PUMP HEATING MODE AIRLOOP F3 S1 | 0.219865 | 3078.57 | 0.000067 |
HEAT PUMP HEATING MODE AIRLOOP F3 S2 | 0.221042 | 3094.11 | 0.000068 |
HEAT PUMP HEATING MODE AIRLOOP F4 SW | 0.346018 | 4603.95 | 0.000101 |
HEAT PUMP HEATING MODE AIRLOOP F4 NW | 0.316536 | 4191.21 | 0.000092 |
HEAT PUMP HEATING MODE AIRLOOP F4 SE | 0.312031 | 4241.97 | 0.000093 |
HEAT PUMP HEATING MODE AIRLOOP F4 NE | 0.246639 | 3285.06 | 0.000072 |
HEAT PUMP HEATING MODE AIRLOOP F4 N1 | 0.165741 | 2212.07 | 0.000048 |
HEAT PUMP HEATING MODE AIRLOOP F4 N2 | 0.164183 | 2191.45 | 0.000048 |
HEAT PUMP HEATING MODE AIRLOOP F4 S1 | 0.222651 | 3108.37 | 0.000068 |
HEAT PUMP HEATING MODE AIRLOOP F4 S2 | 0.223639 | 3121.41 | 0.000068 |
HEAT PUMP HEATING MODE AIRLOOP M SW | 0.350310 | 4650.74 | 0.000102 |
HEAT PUMP HEATING MODE AIRLOOP M NW | 0.320861 | 4238.51 | 0.000093 |
HEAT PUMP HEATING MODE AIRLOOP M SE | 0.317028 | 4298.30 | 0.000094 |
HEAT PUMP HEATING MODE AIRLOOP M NE | 0.251089 | 3334.45 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP M N1 | 0.169545 | 2257.05 | 0.000049 |
HEAT PUMP HEATING MODE AIRLOOP M N2 | 0.167992 | 2236.50 | 0.000049 |
HEAT PUMP HEATING MODE AIRLOOP M S1 | 0.226969 | 3159.62 | 0.000069 |
HEAT PUMP HEATING MODE AIRLOOP M S2 | 0.227929 | 3172.29 | 0.000069 |
HEAT PUMP HEATING MODE AIRLOOP F6 SW | 0.348302 | 4615.94 | 0.000101 |
HEAT PUMP HEATING MODE AIRLOOP F6 NW | 0.318735 | 4202.20 | 0.000092 |
HEAT PUMP HEATING MODE AIRLOOP F6 SE | 0.315863 | 4274.97 | 0.000093 |
HEAT PUMP HEATING MODE AIRLOOP F6 NE | 0.249205 | 3302.10 | 0.000072 |
HEAT PUMP HEATING MODE AIRLOOP F6 N1 | 0.167288 | 2222.52 | 0.000049 |
HEAT PUMP HEATING MODE AIRLOOP F6 N2 | 0.165746 | 2202.14 | 0.000048 |
HEAT PUMP HEATING MODE AIRLOOP F6 S1 | 0.225085 | 3130.01 | 0.000068 |
HEAT PUMP HEATING MODE AIRLOOP F6 S2 | 0.226041 | 3142.63 | 0.000069 |
HEAT PUMP HEATING MODE AIRLOOP F7 SW | 0.348372 | 4609.57 | 0.000101 |
HEAT PUMP HEATING MODE AIRLOOP F7 NW | 0.318782 | 4195.59 | 0.000092 |
HEAT PUMP HEATING MODE AIRLOOP F7 SE | 0.316679 | 4278.69 | 0.000093 |
HEAT PUMP HEATING MODE AIRLOOP F7 NE | 0.249425 | 3298.33 | 0.000072 |
HEAT PUMP HEATING MODE AIRLOOP F7 N1 | 0.167115 | 2216.20 | 0.000048 |
HEAT PUMP HEATING MODE AIRLOOP F7 N2 | 0.165581 | 2195.95 | 0.000048 |
HEAT PUMP HEATING MODE AIRLOOP F7 S1 | 0.225227 | 3127.68 | 0.000068 |
HEAT PUMP HEATING MODE AIRLOOP F7 S2 | 0.226182 | 3140.28 | 0.000069 |
HEAT PUMP HEATING MODE AIRLOOP F8 SW | 0.349698 | 4620.51 | 0.000101 |
HEAT PUMP HEATING MODE AIRLOOP F8 NW | 0.320098 | 4206.46 | 0.000092 |
HEAT PUMP HEATING MODE AIRLOOP F8 SE | 0.318580 | 4297.40 | 0.000094 |
HEAT PUMP HEATING MODE AIRLOOP F8 NE | 0.250791 | 3310.28 | 0.000072 |
HEAT PUMP HEATING MODE AIRLOOP F8 N1 | 0.168238 | 2227.45 | 0.000049 |
HEAT PUMP HEATING MODE AIRLOOP F8 N2 | 0.166714 | 2207.34 | 0.000048 |
HEAT PUMP HEATING MODE AIRLOOP F8 S1 | 0.226545 | 3141.27 | 0.000069 |
HEAT PUMP HEATING MODE AIRLOOP F8 S2 | 0.227502 | 3153.89 | 0.000069 |
HEAT PUMP HEATING MODE AIRLOOP F9 SW | 0.361483 | 4769.64 | 0.000104 |
HEAT PUMP HEATING MODE AIRLOOP F9 NW | 0.331466 | 4350.19 | 0.000095 |
HEAT PUMP HEATING MODE AIRLOOP F9 SE | 0.327754 | 4412.41 | 0.000096 |
HEAT PUMP HEATING MODE AIRLOOP F9 NE | 0.255699 | 3369.06 | 0.000074 |
HEAT PUMP HEATING MODE AIRLOOP F9 N1 | 0.178010 | 2353.31 | 0.000051 |
HEAT PUMP HEATING MODE AIRLOOP F9 N2 | 0.176478 | 2333.10 | 0.000051 |
HEAT PUMP HEATING MODE AIRLOOP F9 S1 | 0.234054 | 3236.76 | 0.000071 |
HEAT PUMP HEATING MODE AIRLOOP F9 S2 | 0.235107 | 3250.41 | 0.000071 |
HEAT PUMP HEATING MODE AIRLOOP T SW | 0.446752 | 5933.42 | 0.000130 |
HEAT PUMP HEATING MODE AIRLOOP T NW | 0.405202 | 5349.33 | 0.000117 |
HEAT PUMP HEATING MODE AIRLOOP T SE | 0.409650 | 5483.46 | 0.000120 |
HEAT PUMP HEATING MODE AIRLOOP T NE | 0.319637 | 4300.51 | 0.000094 |
HEAT PUMP HEATING MODE AIRLOOP T N1 | 0.240293 | 3301.70 | 0.000072 |
HEAT PUMP HEATING MODE AIRLOOP T N2 | 0.240115 | 3306.27 | 0.000072 |
HEAT PUMP HEATING MODE AIRLOOP T S1 | 0.326633 | 4452.28 | 0.000097 |
HEAT PUMP HEATING MODE AIRLOOP T S2 | 0.327472 | 4463.37 | 0.000098 |
Nominal Capacity [W] | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW | 3760.47 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW | 3775.08 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE | 4652.81 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE | 3770.34 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 | 2902.28 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 | 2902.17 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 | 2884.58 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 | 2890.75 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW | 3613.42 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW | 3620.19 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE | 3627.05 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE | 3615.49 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 | 2552.26 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 | 2552.15 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 | 2548.35 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 | 2549.39 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW | 3612.74 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW | 3619.74 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE | 3610.92 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE | 3615.99 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 | 2505.97 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 | 2505.88 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 | 2499.87 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 | 2499.96 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW | 3678.92 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW | 3685.23 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE | 3676.25 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE | 3682.36 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 | 2533.67 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 | 2533.60 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 | 2527.99 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 | 2527.95 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW | 3724.22 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW | 3728.46 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE | 3722.17 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE | 3726.39 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 | 2546.94 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 | 2546.89 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 | 2543.31 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 | 2543.26 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW | 3825.60 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW | 3829.61 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE | 3824.25 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE | 3828.26 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 | 2621.07 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 | 2621.04 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 | 2617.65 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 | 2617.62 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW | 3898.88 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW | 3901.65 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE | 3898.18 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE | 3900.95 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 | 2670.23 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 | 2670.21 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 | 2668.08 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 | 2668.06 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW | 3977.43 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW | 3978.75 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE | 3977.33 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE | 3978.65 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 | 2727.07 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 | 2727.06 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 | 2726.37 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 | 2726.37 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW | 4203.83 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW | 4200.93 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE | 4204.28 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE | 4201.39 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 | 2921.24 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 | 2921.25 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 | 2924.33 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 | 2924.34 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW | 4999.34 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW | 5003.61 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE | 5000.21 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE | 5004.47 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 | 3771.06 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 | 3771.08 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 | 3764.02 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 | 3764.04 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
SHWSYS1 | 0.000289 | 0.325214 |
SINGLE WATER PLANT LOOP | 0.006040 | 6.79 |
Design Water Flow Rate [m3/s] | |
CENTRAL BOILER | 0.006040 |
Use Side Design Flow Rate [m3/s] | |
SHWSYS1 WATER HEATER | 0.000289 |
Design Water Flow Rate [m3/s] | Fan Power at Design Air Flow Rate [W] | Design Air Flow Rate [m3/s] | U-Factor Times Area Value at Design Air Flow Rate [W/C] | |
CENTRAL TOWER | 0.006040 | 2915.75 | 8.34 | 8315.99 |
Rated Flow Rate [m3/s] | Rated Power Consumption [W] | |
SHWSYS1 PUMP | 0.000289 | 36.93 |
PLANT CIRC PUMP | 0.006040 | 1928.84 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:31
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW3 | |
G WWALL SWA | GWINDOW2 | |
G NWALL NWA | GWINDOW4 | |
G WWALL NWA | GWINDOW6 | |
G SWALL SEA | GWINDOW1 | |
G EWALL SEA | GWINDOW8 | |
G NWALL NEA | GWINDOW5 | |
G EWALL NEA | GWINDOW7 | |
G NWALL N1A | GWINDOW9 | |
G NWALL N2A | GWINDOW10 | |
G SWALL S1A | GWINDOW11 | |
G SWALL S2A | GWINDOW12 | |
G WWALL C | GWINDOW13 | |
G EWALL C | ENTRANCE DOOR | |
F2 WWALL SWA | F2WINDOW2 | |
F2 SWALL SWA | F2WINDOW3 | |
F2 NWALL NWA | F2WINDOW4 | |
F2 WWALL NWA | F2WINDOW6 | |
F2 EWALL SEA | F2WINDOW8 | |
F2 SWALL SEA | F2WINDOW1 | |
F2 NWALL NEA | F2WINDOW5 | |
F2 EWALL NEA | F2WINDOW7 | |
F2 NWALL N1A | F2WINDOW9 | |
F2 NWALL N2A | F2WINDOW10 | |
F2 SWALL S1A | F2WINDOW11 | |
F2 SWALL S2A | F2WINDOW12 | |
F2 WWALL C | F2WINDOW13 | |
F2 EWALL C | F2WINDOW14 | |
F3 WWALL SWA | F3WINDOW2 | |
F3 SWALL SWA | F3WINDOW3 | |
F3 NWALL NWA | F3WINDOW4 | |
F3 WWALL NWA | F3WINDOW6 | |
F3 EWALL SEA | F3WINDOW8 | |
F3 SWALL SEA | F3WINDOW1 | |
F3 NWALL NEA | F3WINDOW5 | |
F3 EWALL NEA | F3WINDOW7 | |
F3 NWALL N1A | F3WINDOW9 | |
F3 NWALL N2A | F3WINDOW10 | |
F3 SWALL S1A | F3WINDOW11 | |
F3 SWALL S2A | F3WINDOW12 | |
F3 WWALL C | F3WINDOW13 | |
F3 EWALL C | F3WINDOW14 | |
F4 WWALL SWA | F4WINDOW2 | |
F4 SWALL SWA | F4WINDOW3 | |
F4 NWALL NWA | F4WINDOW4 | |
F4 WWALL NWA | F4WINDOW6 | |
F4 EWALL SEA | F4WINDOW8 | |
F4 SWALL SEA | F4WINDOW1 | |
F4 NWALL NEA | F4WINDOW5 | |
F4 EWALL NEA | F4WINDOW7 | |
F4 NWALL N1A | F4WINDOW9 | |
F4 NWALL N2A | F4WINDOW10 | |
F4 SWALL S1A | F4WINDOW11 | |
F4 SWALL S2A | F4WINDOW12 | |
F4 WWALL C | F4WINDOW13 | |
F4 EWALL C | F4WINDOW14 | |
M WWALL SWA | MWINDOW2 | |
M SWALL SWA | MWINDOW3 | |
M NWALL NWA | MWINDOW4 | |
M WWALL NWA | MWINDOW6 | |
M EWALL SEA | MWINDOW8 | |
M SWALL SEA | MWINDOW1 | |
M NWALL NEA | MWINDOW5 | |
M EWALL NEA | MWINDOW7 | |
M NWALL N1A | MWINDOW9 | |
M NWALL N2A | MWINDOW10 | |
M SWALL S1A | MWINDOW11 | |
M SWALL S2A | MWINDOW12 | |
M WWALL C | MWINDOW13 | |
M EWALL C | MWINDOW14 | |
F6 WWALL SWA | F6WINDOW2 | |
F6 SWALL SWA | F6WINDOW3 | |
F6 NWALL NWA | F6WINDOW4 | |
F6 WWALL NWA | F6WINDOW6 | |
F6 EWALL SEA | F6WINDOW8 | |
F6 SWALL SEA | F6WINDOW1 | |
F6 NWALL NEA | F6WINDOW5 | |
F6 EWALL NEA | F6WINDOW7 | |
F6 NWALL N1A | F6WINDOW9 | |
F6 NWALL N2A | F6WINDOW10 | |
F6 SWALL S1A | F6WINDOW11 | |
F6 SWALL S2A | F6WINDOW12 | |
F6 WWALL C | F6WINDOW13 | |
F6 EWALL C | F6WINDOW14 | |
F7 WWALL SWA | F7WINDOW2 | |
F7 SWALL SWA | F7WINDOW3 | |
F7 NWALL NWA | F7WINDOW4 | |
F7 WWALL NWA | F7WINDOW6 | |
F7 EWALL SEA | F7WINDOW8 | |
F7 SWALL SEA | F7WINDOW1 | |
F7 NWALL NEA | F7WINDOW5 | |
F7 EWALL NEA | F7WINDOW7 | |
F7 NWALL N1A | F7WINDOW9 | |
F7 NWALL N2A | F7WINDOW10 | |
F7 SWALL S1A | F7WINDOW11 | |
F7 SWALL S2A | F7WINDOW12 | |
F7 WWALL C | F7WINDOW13 | |
F7 EWALL C | F7WINDOW14 | |
F8 WWALL SWA | F8WINDOW2 | |
F8 SWALL SWA | F8WINDOW3 | |
F8 NWALL NWA | F8WINDOW4 | |
F8 WWALL NWA | F8WINDOW6 | |
F8 EWALL SEA | F8WINDOW8 | |
F8 SWALL SEA | F8WINDOW1 | |
F8 NWALL NEA | F8WINDOW5 | |
F8 EWALL NEA | F8WINDOW7 | |
F8 NWALL N1A | F8WINDOW9 | |
F8 NWALL N2A | F8WINDOW10 | |
F8 SWALL S1A | F8WINDOW11 | |
F8 SWALL S2A | F8WINDOW12 | |
F8 WWALL C | F8WINDOW13 | |
F8 EWALL C | F8WINDOW14 | |
F9 WWALL SWA | F9WINDOW2 | |
F9 SWALL SWA | F9WINDOW3 | |
F9 NWALL NWA | F9WINDOW4 | |
F9 WWALL NWA | F9WINDOW6 | |
F9 EWALL SEA | F9WINDOW8 | |
F9 SWALL SEA | F9WINDOW1 | |
F9 NWALL NEA | F9WINDOW5 | |
F9 EWALL NEA | F9WINDOW7 | |
F9 NWALL N1A | F9WINDOW9 | |
F9 NWALL N2A | F9WINDOW10 | |
F9 SWALL S1A | F9WINDOW11 | |
F9 SWALL S2A | F9WINDOW12 | |
F9 WWALL C | F9WINDOW13 | |
F9 EWALL C | F9WINDOW14 | |
T WWALL SWA | TWINDOW2 | |
T SWALL SWA | TWINDOW3 | |
T NWALL NWA | TWINDOW4 | |
T WWALL NWA | TWINDOW6 | |
T EWALL SEA | TWINDOW8 | |
T SWALL SEA | TWINDOW1 | |
T NWALL NEA | TWINDOW5 | |
T EWALL NEA | TWINDOW7 | |
T NWALL N1A | TWINDOW9 | |
T NWALL N2A | TWINDOW10 | |
T SWALL S1A | TWINDOW11 | |
T SWALL S2A | TWINDOW12 | |
T WWALL C | TWINDOW13 | |
T EWALL C | TWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:31
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.77 | -1.7 |
February | 22.03 | 2.70 |
March | 22.28 | 6.07 |
April | 23.06 | 11.58 |
May | 23.40 | 14.61 |
June | 24.16 | 19.78 |
July | 24.35 | 24.54 |
August | 24.30 | 21.22 |
September | 24.17 | 17.37 |
October | 23.25 | 11.70 |
November | 22.14 | 4.05 |
December | 21.88 | 1.86 |
Annual Sum or Average | 23.07 | 11.20 |
Minimum of Months | 21.77 | -1.7 |
Maximum of Months | 24.35 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.72 | 2.70 |
March | 21.84 | 6.07 |
April | 22.60 | 11.58 |
May | 23.15 | 14.61 |
June | 24.14 | 19.78 |
July | 24.35 | 24.54 |
August | 24.23 | 21.22 |
September | 23.96 | 17.37 |
October | 22.47 | 11.70 |
November | 21.76 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 22.81 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.35 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.01 | -1.7 |
February | 22.25 | 2.70 |
March | 22.63 | 6.07 |
April | 23.43 | 11.58 |
May | 23.80 | 14.61 |
June | 24.29 | 19.78 |
July | 24.40 | 24.54 |
August | 24.35 | 21.22 |
September | 24.29 | 17.37 |
October | 23.54 | 11.70 |
November | 22.47 | 4.05 |
December | 22.12 | 1.86 |
Annual Sum or Average | 23.30 | 11.20 |
Minimum of Months | 22.01 | -1.7 |
Maximum of Months | 24.40 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.70 | 2.70 |
March | 21.78 | 6.07 |
April | 22.54 | 11.58 |
May | 23.06 | 14.61 |
June | 24.13 | 19.78 |
July | 24.36 | 24.54 |
August | 24.20 | 21.22 |
September | 23.88 | 17.37 |
October | 22.39 | 11.70 |
November | 21.74 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 22.77 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.36 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.70 | 2.70 |
March | 21.74 | 6.07 |
April | 22.31 | 11.58 |
May | 22.78 | 14.61 |
June | 24.04 | 19.78 |
July | 24.34 | 24.54 |
August | 24.14 | 21.22 |
September | 23.80 | 17.37 |
October | 22.27 | 11.70 |
November | 21.74 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 22.69 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.34 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.70 | 2.70 |
March | 21.74 | 6.07 |
April | 22.31 | 11.58 |
May | 22.77 | 14.61 |
June | 24.04 | 19.78 |
July | 24.34 | 24.54 |
August | 24.14 | 21.22 |
September | 23.80 | 17.37 |
October | 22.27 | 11.70 |
November | 21.74 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 22.69 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.34 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.79 | -1.7 |
February | 22.05 | 2.70 |
March | 22.28 | 6.07 |
April | 22.99 | 11.58 |
May | 23.22 | 14.61 |
June | 24.13 | 19.78 |
July | 24.32 | 24.54 |
August | 24.27 | 21.22 |
September | 24.18 | 17.37 |
October | 23.35 | 11.70 |
November | 22.20 | 4.05 |
December | 21.92 | 1.86 |
Annual Sum or Average | 23.06 | 11.20 |
Minimum of Months | 21.79 | -1.7 |
Maximum of Months | 24.32 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.80 | -1.7 |
February | 22.07 | 2.70 |
March | 22.32 | 6.07 |
April | 23.06 | 11.58 |
May | 23.29 | 14.61 |
June | 24.15 | 19.78 |
July | 24.32 | 24.54 |
August | 24.28 | 21.22 |
September | 24.20 | 17.37 |
October | 23.40 | 11.70 |
November | 22.23 | 4.05 |
December | 21.94 | 1.86 |
Annual Sum or Average | 23.09 | 11.20 |
Minimum of Months | 21.80 | -1.7 |
Maximum of Months | 24.32 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 15.22 | -1.7 |
February | 16.84 | 2.70 |
March | 18.07 | 6.07 |
April | 20.38 | 11.58 |
May | 21.52 | 14.61 |
June | 24.27 | 19.78 |
July | 26.04 | 24.54 |
August | 25.01 | 21.22 |
September | 23.43 | 17.37 |
October | 20.51 | 11.70 |
November | 17.28 | 4.05 |
December | 16.31 | 1.86 |
Annual Sum or Average | 20.43 | 11.20 |
Minimum of Months | 15.22 | -1.7 |
Maximum of Months | 26.04 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F2 SW APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.85 | -1.7 |
February | 22.29 | 2.70 |
March | 22.74 | 6.07 |
April | 23.83 | 11.58 |
May | 24.15 | 14.61 |
June | 24.32 | 19.78 |
July | 24.39 | 24.54 |
August | 24.38 | 21.22 |
September | 24.32 | 17.37 |
October | 23.93 | 11.70 |
November | 22.53 | 4.05 |
December | 22.05 | 1.86 |
Annual Sum or Average | 23.40 | 11.20 |
Minimum of Months | 21.85 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F2 NW APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.75 | 2.70 |
March | 21.99 | 6.07 |
April | 23.32 | 11.58 |
May | 23.97 | 14.61 |
June | 24.30 | 19.78 |
July | 24.39 | 24.54 |
August | 24.33 | 21.22 |
September | 24.16 | 17.37 |
October | 23.03 | 11.70 |
November | 21.90 | 4.05 |
December | 21.71 | 1.86 |
Annual Sum or Average | 23.05 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F2 SE APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.88 | -1.7 |
February | 22.35 | 2.70 |
March | 22.91 | 6.07 |
April | 23.96 | 11.58 |
May | 24.21 | 14.61 |
June | 24.35 | 19.78 |
July | 24.39 | 24.54 |
August | 24.38 | 21.22 |
September | 24.33 | 17.37 |
October | 24.02 | 11.70 |
November | 22.62 | 4.05 |
December | 22.11 | 1.86 |
Annual Sum or Average | 23.46 | 11.20 |
Minimum of Months | 21.88 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F2 NE APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.72 | 2.70 |
March | 21.94 | 6.07 |
April | 23.27 | 11.58 |
May | 23.88 | 14.61 |
June | 24.30 | 19.78 |
July | 24.39 | 24.54 |
August | 24.32 | 21.22 |
September | 24.09 | 17.37 |
October | 22.93 | 11.70 |
November | 21.84 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 23.01 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F2 N1 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.72 | 2.70 |
March | 21.86 | 6.07 |
April | 23.08 | 11.58 |
May | 23.75 | 14.61 |
June | 24.26 | 19.78 |
July | 24.38 | 24.54 |
August | 24.29 | 21.22 |
September | 24.04 | 17.37 |
October | 22.87 | 11.70 |
November | 21.89 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 22.97 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.38 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F2 N2 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.72 | 2.70 |
March | 21.86 | 6.07 |
April | 23.08 | 11.58 |
May | 23.74 | 14.61 |
June | 24.26 | 19.78 |
July | 24.39 | 24.54 |
August | 24.29 | 21.22 |
September | 24.03 | 17.37 |
October | 22.86 | 11.70 |
November | 21.88 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 22.97 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F2 S1 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.92 | -1.7 |
February | 22.45 | 2.70 |
March | 22.91 | 6.07 |
April | 23.90 | 11.58 |
May | 24.11 | 14.61 |
June | 24.30 | 19.78 |
July | 24.37 | 24.54 |
August | 24.36 | 21.22 |
September | 24.33 | 17.37 |
October | 24.09 | 11.70 |
November | 22.71 | 4.05 |
December | 22.22 | 1.86 |
Annual Sum or Average | 23.48 | 11.20 |
Minimum of Months | 21.92 | -1.7 |
Maximum of Months | 24.37 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F2 S2 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.92 | -1.7 |
February | 22.46 | 2.70 |
March | 22.94 | 6.07 |
April | 23.92 | 11.58 |
May | 24.12 | 14.61 |
June | 24.31 | 19.78 |
July | 24.37 | 24.54 |
August | 24.36 | 21.22 |
September | 24.33 | 17.37 |
October | 24.10 | 11.70 |
November | 22.73 | 4.05 |
December | 22.23 | 1.86 |
Annual Sum or Average | 23.49 | 11.20 |
Minimum of Months | 21.92 | -1.7 |
Maximum of Months | 24.37 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F2 CORRIDOR
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.28 | -1.7 |
February | 22.09 | 2.70 |
March | 22.76 | 6.07 |
April | 24.44 | 11.58 |
May | 25.10 | 14.61 |
June | 26.11 | 19.78 |
July | 26.62 | 24.54 |
August | 26.29 | 21.22 |
September | 25.76 | 17.37 |
October | 24.39 | 11.70 |
November | 22.36 | 4.05 |
December | 21.69 | 1.86 |
Annual Sum or Average | 24.08 | 11.20 |
Minimum of Months | 21.28 | -1.7 |
Maximum of Months | 26.62 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F3 SW APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.86 | -1.7 |
February | 22.33 | 2.70 |
March | 22.83 | 6.07 |
April | 23.93 | 11.58 |
May | 24.23 | 14.61 |
June | 24.32 | 19.78 |
July | 24.39 | 24.54 |
August | 24.38 | 21.22 |
September | 24.32 | 17.37 |
October | 24.02 | 11.70 |
November | 22.61 | 4.05 |
December | 22.09 | 1.86 |
Annual Sum or Average | 23.45 | 11.20 |
Minimum of Months | 21.86 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F3 NW APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.77 | 2.70 |
March | 22.02 | 6.07 |
April | 23.46 | 11.58 |
May | 24.10 | 14.61 |
June | 24.30 | 19.78 |
July | 24.39 | 24.54 |
August | 24.34 | 21.22 |
September | 24.17 | 17.37 |
October | 23.17 | 11.70 |
November | 21.96 | 4.05 |
December | 21.71 | 1.86 |
Annual Sum or Average | 23.10 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F3 SE APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.84 | -1.7 |
February | 22.31 | 2.70 |
March | 22.86 | 6.07 |
April | 23.97 | 11.58 |
May | 24.23 | 14.61 |
June | 24.34 | 19.78 |
July | 24.39 | 24.54 |
August | 24.37 | 21.22 |
September | 24.31 | 17.37 |
October | 24.03 | 11.70 |
November | 22.59 | 4.05 |
December | 22.07 | 1.86 |
Annual Sum or Average | 23.45 | 11.20 |
Minimum of Months | 21.84 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F3 NE APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.72 | 2.70 |
March | 21.97 | 6.07 |
April | 23.42 | 11.58 |
May | 24.02 | 14.61 |
June | 24.31 | 19.78 |
July | 24.39 | 24.54 |
August | 24.33 | 21.22 |
September | 24.10 | 17.37 |
October | 23.08 | 11.70 |
November | 21.88 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 23.06 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F3 N1 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.73 | 2.70 |
March | 21.91 | 6.07 |
April | 23.31 | 11.58 |
May | 23.98 | 14.61 |
June | 24.28 | 19.78 |
July | 24.39 | 24.54 |
August | 24.30 | 21.22 |
September | 24.07 | 17.37 |
October | 23.08 | 11.70 |
November | 21.98 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 23.04 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F3 N2 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.73 | 2.70 |
March | 21.91 | 6.07 |
April | 23.31 | 11.58 |
May | 23.97 | 14.61 |
June | 24.28 | 19.78 |
July | 24.39 | 24.54 |
August | 24.30 | 21.22 |
September | 24.06 | 17.37 |
October | 23.07 | 11.70 |
November | 21.97 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 23.04 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F3 S1 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.95 | -1.7 |
February | 22.57 | 2.70 |
March | 23.10 | 6.07 |
April | 24.04 | 11.58 |
May | 24.23 | 14.61 |
June | 24.32 | 19.78 |
July | 24.37 | 24.54 |
August | 24.36 | 21.22 |
September | 24.34 | 17.37 |
October | 24.21 | 11.70 |
November | 22.86 | 4.05 |
December | 22.32 | 1.86 |
Annual Sum or Average | 23.56 | 11.20 |
Minimum of Months | 21.95 | -1.7 |
Maximum of Months | 24.37 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F3 S2 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.95 | -1.7 |
February | 22.57 | 2.70 |
March | 23.11 | 6.07 |
April | 24.05 | 11.58 |
May | 24.24 | 14.61 |
June | 24.32 | 19.78 |
July | 24.37 | 24.54 |
August | 24.36 | 21.22 |
September | 24.34 | 17.37 |
October | 24.21 | 11.70 |
November | 22.86 | 4.05 |
December | 22.32 | 1.86 |
Annual Sum or Average | 23.56 | 11.20 |
Minimum of Months | 21.95 | -1.7 |
Maximum of Months | 24.37 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F3 CORRIDOR
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.82 | -1.7 |
February | 22.59 | 2.70 |
March | 23.25 | 6.07 |
April | 24.97 | 11.58 |
May | 25.63 | 14.61 |
June | 26.31 | 19.78 |
July | 26.72 | 24.54 |
August | 26.42 | 21.22 |
September | 25.97 | 17.37 |
October | 24.87 | 11.70 |
November | 22.88 | 4.05 |
December | 22.18 | 1.86 |
Annual Sum or Average | 24.47 | 11.20 |
Minimum of Months | 21.82 | -1.7 |
Maximum of Months | 26.72 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F4 SW APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.85 | -1.7 |
February | 22.31 | 2.70 |
March | 22.81 | 6.07 |
April | 23.91 | 11.58 |
May | 24.24 | 14.61 |
June | 24.31 | 19.78 |
July | 24.39 | 24.54 |
August | 24.38 | 21.22 |
September | 24.32 | 17.37 |
October | 24.02 | 11.70 |
November | 22.61 | 4.05 |
December | 22.08 | 1.86 |
Annual Sum or Average | 23.44 | 11.20 |
Minimum of Months | 21.85 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F4 NW APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.77 | 2.70 |
March | 22.01 | 6.07 |
April | 23.46 | 11.58 |
May | 24.12 | 14.61 |
June | 24.29 | 19.78 |
July | 24.40 | 24.54 |
August | 24.33 | 21.22 |
September | 24.16 | 17.37 |
October | 23.19 | 11.70 |
November | 21.98 | 4.05 |
December | 21.71 | 1.86 |
Annual Sum or Average | 23.10 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.40 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F4 SE APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.83 | -1.7 |
February | 22.29 | 2.70 |
March | 22.82 | 6.07 |
April | 23.94 | 11.58 |
May | 24.22 | 14.61 |
June | 24.33 | 19.78 |
July | 24.39 | 24.54 |
August | 24.37 | 21.22 |
September | 24.30 | 17.37 |
October | 24.02 | 11.70 |
November | 22.58 | 4.05 |
December | 22.05 | 1.86 |
Annual Sum or Average | 23.43 | 11.20 |
Minimum of Months | 21.83 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F4 NE APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.73 | 2.70 |
March | 21.97 | 6.07 |
April | 23.43 | 11.58 |
May | 24.04 | 14.61 |
June | 24.30 | 19.78 |
July | 24.40 | 24.54 |
August | 24.32 | 21.22 |
September | 24.10 | 17.37 |
October | 23.10 | 11.70 |
November | 21.90 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 23.06 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.40 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F4 N1 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.73 | 2.70 |
March | 21.92 | 6.07 |
April | 23.36 | 11.58 |
May | 24.04 | 14.61 |
June | 24.28 | 19.78 |
July | 24.40 | 24.54 |
August | 24.30 | 21.22 |
September | 24.08 | 17.37 |
October | 23.14 | 11.70 |
November | 22.02 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 23.06 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.40 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F4 N2 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.73 | 2.70 |
March | 21.92 | 6.07 |
April | 23.36 | 11.58 |
May | 24.03 | 14.61 |
June | 24.29 | 19.78 |
July | 24.40 | 24.54 |
August | 24.30 | 21.22 |
September | 24.07 | 17.37 |
October | 23.14 | 11.70 |
November | 22.01 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 23.06 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.40 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F4 S1 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.95 | -1.7 |
February | 22.58 | 2.70 |
March | 23.11 | 6.07 |
April | 24.06 | 11.58 |
May | 24.26 | 14.61 |
June | 24.31 | 19.78 |
July | 24.37 | 24.54 |
August | 24.36 | 21.22 |
September | 24.35 | 17.37 |
October | 24.22 | 11.70 |
November | 22.88 | 4.05 |
December | 22.33 | 1.86 |
Annual Sum or Average | 23.57 | 11.20 |
Minimum of Months | 21.95 | -1.7 |
Maximum of Months | 24.37 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F4 S2 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.95 | -1.7 |
February | 22.58 | 2.70 |
March | 23.12 | 6.07 |
April | 24.06 | 11.58 |
May | 24.26 | 14.61 |
June | 24.32 | 19.78 |
July | 24.37 | 24.54 |
August | 24.36 | 21.22 |
September | 24.35 | 17.37 |
October | 24.22 | 11.70 |
November | 22.88 | 4.05 |
December | 22.33 | 1.86 |
Annual Sum or Average | 23.57 | 11.20 |
Minimum of Months | 21.95 | -1.7 |
Maximum of Months | 24.37 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F4 CORRIDOR
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.96 | -1.7 |
February | 22.73 | 2.70 |
March | 23.38 | 6.07 |
April | 25.13 | 11.58 |
May | 25.80 | 14.61 |
June | 26.40 | 19.78 |
July | 26.80 | 24.54 |
August | 26.50 | 21.22 |
September | 26.07 | 17.37 |
October | 25.02 | 11.70 |
November | 23.04 | 4.05 |
December | 22.31 | 1.86 |
Annual Sum or Average | 24.61 | 11.20 |
Minimum of Months | 21.96 | -1.7 |
Maximum of Months | 26.80 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.84 | -1.7 |
February | 22.30 | 2.70 |
March | 22.78 | 6.07 |
April | 23.89 | 11.58 |
May | 24.23 | 14.61 |
June | 24.30 | 19.78 |
July | 24.39 | 24.54 |
August | 24.38 | 21.22 |
September | 24.32 | 17.37 |
October | 24.01 | 11.70 |
November | 22.60 | 4.05 |
December | 22.07 | 1.86 |
Annual Sum or Average | 23.43 | 11.20 |
Minimum of Months | 21.84 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.77 | 2.70 |
March | 22.01 | 6.07 |
April | 23.44 | 11.58 |
May | 24.11 | 14.61 |
June | 24.28 | 19.78 |
July | 24.40 | 24.54 |
August | 24.33 | 21.22 |
September | 24.15 | 17.37 |
October | 23.18 | 11.70 |
November | 21.98 | 4.05 |
December | 21.71 | 1.86 |
Annual Sum or Average | 23.10 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.40 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.83 | -1.7 |
February | 22.27 | 2.70 |
March | 22.79 | 6.07 |
April | 23.91 | 11.58 |
May | 24.21 | 14.61 |
June | 24.32 | 19.78 |
July | 24.39 | 24.54 |
August | 24.37 | 21.22 |
September | 24.30 | 17.37 |
October | 24.01 | 11.70 |
November | 22.56 | 4.05 |
December | 22.04 | 1.86 |
Annual Sum or Average | 23.42 | 11.20 |
Minimum of Months | 21.83 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.73 | 2.70 |
March | 21.96 | 6.07 |
April | 23.41 | 11.58 |
May | 24.04 | 14.61 |
June | 24.29 | 19.78 |
July | 24.40 | 24.54 |
August | 24.32 | 21.22 |
September | 24.09 | 17.37 |
October | 23.10 | 11.70 |
November | 21.90 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 23.06 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.40 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.74 | 2.70 |
March | 21.93 | 6.07 |
April | 23.37 | 11.58 |
May | 24.05 | 14.61 |
June | 24.28 | 19.78 |
July | 24.40 | 24.54 |
August | 24.30 | 21.22 |
September | 24.08 | 17.37 |
October | 23.16 | 11.70 |
November | 22.03 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 23.07 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.40 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.74 | 2.70 |
March | 21.93 | 6.07 |
April | 23.37 | 11.58 |
May | 24.04 | 14.61 |
June | 24.28 | 19.78 |
July | 24.40 | 24.54 |
August | 24.30 | 21.22 |
September | 24.07 | 17.37 |
October | 23.16 | 11.70 |
November | 22.02 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 23.07 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.40 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.95 | -1.7 |
February | 22.57 | 2.70 |
March | 23.10 | 6.07 |
April | 24.05 | 11.58 |
May | 24.26 | 14.61 |
June | 24.31 | 19.78 |
July | 24.37 | 24.54 |
August | 24.36 | 21.22 |
September | 24.34 | 17.37 |
October | 24.22 | 11.70 |
November | 22.89 | 4.05 |
December | 22.34 | 1.86 |
Annual Sum or Average | 23.57 | 11.20 |
Minimum of Months | 21.95 | -1.7 |
Maximum of Months | 24.37 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.95 | -1.7 |
February | 22.57 | 2.70 |
March | 23.11 | 6.07 |
April | 24.05 | 11.58 |
May | 24.26 | 14.61 |
June | 24.31 | 19.78 |
July | 24.37 | 24.54 |
August | 24.36 | 21.22 |
September | 24.34 | 17.37 |
October | 24.22 | 11.70 |
November | 22.89 | 4.05 |
December | 22.34 | 1.86 |
Annual Sum or Average | 23.57 | 11.20 |
Minimum of Months | 21.95 | -1.7 |
Maximum of Months | 24.37 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.55 | -1.7 |
February | 23.30 | 2.70 |
March | 23.94 | 6.07 |
April | 25.67 | 11.58 |
May | 26.35 | 14.61 |
June | 26.93 | 19.78 |
July | 27.33 | 24.54 |
August | 27.03 | 21.22 |
September | 26.60 | 17.37 |
October | 25.58 | 11.70 |
November | 23.62 | 4.05 |
December | 22.89 | 1.86 |
Annual Sum or Average | 25.16 | 11.20 |
Minimum of Months | 22.55 | -1.7 |
Maximum of Months | 27.33 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F6 SW APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.82 | -1.7 |
February | 22.25 | 2.70 |
March | 22.68 | 6.07 |
April | 23.82 | 11.58 |
May | 24.19 | 14.61 |
June | 24.28 | 19.78 |
July | 24.39 | 24.54 |
August | 24.37 | 21.22 |
September | 24.30 | 17.37 |
October | 23.94 | 11.70 |
November | 22.54 | 4.05 |
December | 22.04 | 1.86 |
Annual Sum or Average | 23.39 | 11.20 |
Minimum of Months | 21.82 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F6 NW APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.76 | 2.70 |
March | 21.96 | 6.07 |
April | 23.34 | 11.58 |
May | 24.04 | 14.61 |
June | 24.26 | 19.78 |
July | 24.39 | 24.54 |
August | 24.31 | 21.22 |
September | 24.10 | 17.37 |
October | 23.07 | 11.70 |
November | 21.93 | 4.05 |
December | 21.71 | 1.86 |
Annual Sum or Average | 23.06 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F6 SE APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.81 | -1.7 |
February | 22.22 | 2.70 |
March | 22.70 | 6.07 |
April | 23.84 | 11.58 |
May | 24.17 | 14.61 |
June | 24.31 | 19.78 |
July | 24.39 | 24.54 |
August | 24.36 | 21.22 |
September | 24.27 | 17.37 |
October | 23.94 | 11.70 |
November | 22.50 | 4.05 |
December | 22.01 | 1.86 |
Annual Sum or Average | 23.38 | 11.20 |
Minimum of Months | 21.81 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F6 NE APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.72 | 2.70 |
March | 21.92 | 6.07 |
April | 23.31 | 11.58 |
May | 23.97 | 14.61 |
June | 24.26 | 19.78 |
July | 24.40 | 24.54 |
August | 24.30 | 21.22 |
September | 24.03 | 17.37 |
October | 22.98 | 11.70 |
November | 21.87 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 23.02 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.40 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F6 N1 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.73 | 2.70 |
March | 21.89 | 6.07 |
April | 23.26 | 11.58 |
May | 23.98 | 14.61 |
June | 24.25 | 19.78 |
July | 24.40 | 24.54 |
August | 24.28 | 21.22 |
September | 24.02 | 17.37 |
October | 23.04 | 11.70 |
November | 21.98 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 23.03 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.40 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F6 N2 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.73 | 2.70 |
March | 21.89 | 6.07 |
April | 23.26 | 11.58 |
May | 23.97 | 14.61 |
June | 24.25 | 19.78 |
July | 24.40 | 24.54 |
August | 24.28 | 21.22 |
September | 24.01 | 17.37 |
October | 23.04 | 11.70 |
November | 21.98 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 23.02 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.40 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F6 S1 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.92 | -1.7 |
February | 22.49 | 2.70 |
March | 23.00 | 6.07 |
April | 23.98 | 11.58 |
May | 24.22 | 14.61 |
June | 24.29 | 19.78 |
July | 24.37 | 24.54 |
August | 24.35 | 21.22 |
September | 24.32 | 17.37 |
October | 24.17 | 11.70 |
November | 22.82 | 4.05 |
December | 22.28 | 1.86 |
Annual Sum or Average | 23.52 | 11.20 |
Minimum of Months | 21.92 | -1.7 |
Maximum of Months | 24.37 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F6 S2 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.92 | -1.7 |
February | 22.49 | 2.70 |
March | 23.00 | 6.07 |
April | 23.99 | 11.58 |
May | 24.22 | 14.61 |
June | 24.29 | 19.78 |
July | 24.37 | 24.54 |
August | 24.35 | 21.22 |
September | 24.32 | 17.37 |
October | 24.18 | 11.70 |
November | 22.82 | 4.05 |
December | 22.28 | 1.86 |
Annual Sum or Average | 23.52 | 11.20 |
Minimum of Months | 21.92 | -1.7 |
Maximum of Months | 24.37 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F6 CORRIDOR
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.92 | -1.7 |
February | 22.66 | 2.70 |
March | 23.29 | 6.07 |
April | 25.03 | 11.58 |
May | 25.74 | 14.61 |
June | 26.36 | 19.78 |
July | 26.79 | 24.54 |
August | 26.47 | 21.22 |
September | 26.01 | 17.37 |
October | 24.94 | 11.70 |
November | 22.98 | 4.05 |
December | 22.26 | 1.86 |
Annual Sum or Average | 24.55 | 11.20 |
Minimum of Months | 21.92 | -1.7 |
Maximum of Months | 26.79 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F7 SW APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.81 | -1.7 |
February | 22.21 | 2.70 |
March | 22.61 | 6.07 |
April | 23.75 | 11.58 |
May | 24.16 | 14.61 |
June | 24.27 | 19.78 |
July | 24.39 | 24.54 |
August | 24.36 | 21.22 |
September | 24.28 | 17.37 |
October | 23.89 | 11.70 |
November | 22.49 | 4.05 |
December | 22.01 | 1.86 |
Annual Sum or Average | 23.36 | 11.20 |
Minimum of Months | 21.81 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F7 NW APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.75 | 2.70 |
March | 21.93 | 6.07 |
April | 23.27 | 11.58 |
May | 23.99 | 14.61 |
June | 24.24 | 19.78 |
July | 24.39 | 24.54 |
August | 24.30 | 21.22 |
September | 24.06 | 17.37 |
October | 22.99 | 11.70 |
November | 21.90 | 4.05 |
December | 21.71 | 1.86 |
Annual Sum or Average | 23.03 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F7 SE APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.80 | -1.7 |
February | 22.18 | 2.70 |
March | 22.63 | 6.07 |
April | 23.78 | 11.58 |
May | 24.13 | 14.61 |
June | 24.29 | 19.78 |
July | 24.39 | 24.54 |
August | 24.35 | 21.22 |
September | 24.25 | 17.37 |
October | 23.89 | 11.70 |
November | 22.46 | 4.05 |
December | 21.98 | 1.86 |
Annual Sum or Average | 23.35 | 11.20 |
Minimum of Months | 21.80 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F7 NE APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.72 | 2.70 |
March | 21.89 | 6.07 |
April | 23.23 | 11.58 |
May | 23.92 | 14.61 |
June | 24.24 | 19.78 |
July | 24.40 | 24.54 |
August | 24.28 | 21.22 |
September | 23.98 | 17.37 |
October | 22.89 | 11.70 |
November | 21.84 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 22.99 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.40 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F7 N1 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.73 | 2.70 |
March | 21.86 | 6.07 |
April | 23.18 | 11.58 |
May | 23.92 | 14.61 |
June | 24.23 | 19.78 |
July | 24.40 | 24.54 |
August | 24.26 | 21.22 |
September | 23.98 | 17.37 |
October | 22.95 | 11.70 |
November | 21.94 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 22.99 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.40 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F7 N2 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.72 | 2.70 |
March | 21.86 | 6.07 |
April | 23.18 | 11.58 |
May | 23.91 | 14.61 |
June | 24.23 | 19.78 |
July | 24.40 | 24.54 |
August | 24.26 | 21.22 |
September | 23.97 | 17.37 |
October | 22.94 | 11.70 |
November | 21.94 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 22.99 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.40 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F7 S1 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.90 | -1.7 |
February | 22.44 | 2.70 |
March | 22.91 | 6.07 |
April | 23.93 | 11.58 |
May | 24.19 | 14.61 |
June | 24.28 | 19.78 |
July | 24.37 | 24.54 |
August | 24.34 | 21.22 |
September | 24.31 | 17.37 |
October | 24.13 | 11.70 |
November | 22.77 | 4.05 |
December | 22.23 | 1.86 |
Annual Sum or Average | 23.49 | 11.20 |
Minimum of Months | 21.90 | -1.7 |
Maximum of Months | 24.37 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F7 S2 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.90 | -1.7 |
February | 22.44 | 2.70 |
March | 22.92 | 6.07 |
April | 23.93 | 11.58 |
May | 24.19 | 14.61 |
June | 24.28 | 19.78 |
July | 24.37 | 24.54 |
August | 24.34 | 21.22 |
September | 24.31 | 17.37 |
October | 24.14 | 11.70 |
November | 22.76 | 4.05 |
December | 22.23 | 1.86 |
Annual Sum or Average | 23.49 | 11.20 |
Minimum of Months | 21.90 | -1.7 |
Maximum of Months | 24.37 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F7 CORRIDOR
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.78 | -1.7 |
February | 22.51 | 2.70 |
March | 23.12 | 6.07 |
April | 24.86 | 11.58 |
May | 25.60 | 14.61 |
June | 26.26 | 19.78 |
July | 26.72 | 24.54 |
August | 26.38 | 21.22 |
September | 25.89 | 17.37 |
October | 24.78 | 11.70 |
November | 22.82 | 4.05 |
December | 22.12 | 1.86 |
Annual Sum or Average | 24.41 | 11.20 |
Minimum of Months | 21.78 | -1.7 |
Maximum of Months | 26.72 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F8 SW APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.80 | -1.7 |
February | 22.18 | 2.70 |
March | 22.56 | 6.07 |
April | 23.70 | 11.58 |
May | 24.12 | 14.61 |
June | 24.26 | 19.78 |
July | 24.39 | 24.54 |
August | 24.35 | 21.22 |
September | 24.26 | 17.37 |
October | 23.83 | 11.70 |
November | 22.44 | 4.05 |
December | 21.99 | 1.86 |
Annual Sum or Average | 23.33 | 11.20 |
Minimum of Months | 21.80 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F8 NW APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.75 | 2.70 |
March | 21.91 | 6.07 |
April | 23.20 | 11.58 |
May | 23.94 | 14.61 |
June | 24.23 | 19.78 |
July | 24.39 | 24.54 |
August | 24.29 | 21.22 |
September | 24.03 | 17.37 |
October | 22.92 | 11.70 |
November | 21.87 | 4.05 |
December | 21.71 | 1.86 |
Annual Sum or Average | 23.00 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F8 SE APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.79 | -1.7 |
February | 22.15 | 2.70 |
March | 22.58 | 6.07 |
April | 23.73 | 11.58 |
May | 24.10 | 14.61 |
June | 24.28 | 19.78 |
July | 24.39 | 24.54 |
August | 24.35 | 21.22 |
September | 24.23 | 17.37 |
October | 23.84 | 11.70 |
November | 22.41 | 4.05 |
December | 21.96 | 1.86 |
Annual Sum or Average | 23.32 | 11.20 |
Minimum of Months | 21.79 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F8 NE APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.72 | 2.70 |
March | 21.87 | 6.07 |
April | 23.16 | 11.58 |
May | 23.87 | 14.61 |
June | 24.22 | 19.78 |
July | 24.40 | 24.54 |
August | 24.27 | 21.22 |
September | 23.94 | 17.37 |
October | 22.82 | 11.70 |
November | 21.82 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 22.96 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.40 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F8 N1 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.72 | 2.70 |
March | 21.84 | 6.07 |
April | 23.11 | 11.58 |
May | 23.86 | 14.61 |
June | 24.21 | 19.78 |
July | 24.39 | 24.54 |
August | 24.25 | 21.22 |
September | 23.94 | 17.37 |
October | 22.87 | 11.70 |
November | 21.90 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 22.96 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F8 N2 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.72 | 2.70 |
March | 21.84 | 6.07 |
April | 23.11 | 11.58 |
May | 23.85 | 14.61 |
June | 24.21 | 19.78 |
July | 24.40 | 24.54 |
August | 24.25 | 21.22 |
September | 23.93 | 17.37 |
October | 22.86 | 11.70 |
November | 21.90 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 22.96 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.40 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F8 S1 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.88 | -1.7 |
February | 22.39 | 2.70 |
March | 22.84 | 6.07 |
April | 23.88 | 11.58 |
May | 24.16 | 14.61 |
June | 24.27 | 19.78 |
July | 24.37 | 24.54 |
August | 24.34 | 21.22 |
September | 24.29 | 17.37 |
October | 24.09 | 11.70 |
November | 22.70 | 4.05 |
December | 22.19 | 1.86 |
Annual Sum or Average | 23.45 | 11.20 |
Minimum of Months | 21.88 | -1.7 |
Maximum of Months | 24.37 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F8 S2 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.88 | -1.7 |
February | 22.39 | 2.70 |
March | 22.84 | 6.07 |
April | 23.88 | 11.58 |
May | 24.16 | 14.61 |
June | 24.27 | 19.78 |
July | 24.37 | 24.54 |
August | 24.34 | 21.22 |
September | 24.29 | 17.37 |
October | 24.09 | 11.70 |
November | 22.70 | 4.05 |
December | 22.19 | 1.86 |
Annual Sum or Average | 23.45 | 11.20 |
Minimum of Months | 21.88 | -1.7 |
Maximum of Months | 24.37 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F8 CORRIDOR
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.69 | -1.7 |
February | 22.42 | 2.70 |
March | 23.03 | 6.07 |
April | 24.77 | 11.58 |
May | 25.52 | 14.61 |
June | 26.23 | 19.78 |
July | 26.72 | 24.54 |
August | 26.36 | 21.22 |
September | 25.83 | 17.37 |
October | 24.67 | 11.70 |
November | 22.71 | 4.05 |
December | 22.03 | 1.86 |
Annual Sum or Average | 24.34 | 11.20 |
Minimum of Months | 21.69 | -1.7 |
Maximum of Months | 26.72 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F9 SW APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.79 | -1.7 |
February | 22.14 | 2.70 |
March | 22.49 | 6.07 |
April | 23.62 | 11.58 |
May | 24.07 | 14.61 |
June | 24.24 | 19.78 |
July | 24.39 | 24.54 |
August | 24.34 | 21.22 |
September | 24.23 | 17.37 |
October | 23.73 | 11.70 |
November | 22.37 | 4.05 |
December | 21.95 | 1.86 |
Annual Sum or Average | 23.29 | 11.20 |
Minimum of Months | 21.79 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F9 NW APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.74 | 2.70 |
March | 21.90 | 6.07 |
April | 23.14 | 11.58 |
May | 23.88 | 14.61 |
June | 24.21 | 19.78 |
July | 24.39 | 24.54 |
August | 24.27 | 21.22 |
September | 23.97 | 17.37 |
October | 22.84 | 11.70 |
November | 21.84 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 22.97 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F9 SE APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.77 | -1.7 |
February | 22.11 | 2.70 |
March | 22.52 | 6.07 |
April | 23.65 | 11.58 |
May | 24.05 | 14.61 |
June | 24.26 | 19.78 |
July | 24.39 | 24.54 |
August | 24.34 | 21.22 |
September | 24.20 | 17.37 |
October | 23.74 | 11.70 |
November | 22.34 | 4.05 |
December | 21.93 | 1.86 |
Annual Sum or Average | 23.28 | 11.20 |
Minimum of Months | 21.77 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F9 NE APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.71 | 2.70 |
March | 21.85 | 6.07 |
April | 23.09 | 11.58 |
May | 23.81 | 14.61 |
June | 24.20 | 19.78 |
July | 24.40 | 24.54 |
August | 24.25 | 21.22 |
September | 23.88 | 17.37 |
October | 22.74 | 11.70 |
November | 21.80 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 22.94 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.40 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F9 N1 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.72 | 2.70 |
March | 21.83 | 6.07 |
April | 23.05 | 11.58 |
May | 23.79 | 14.61 |
June | 24.19 | 19.78 |
July | 24.39 | 24.54 |
August | 24.23 | 21.22 |
September | 23.89 | 17.37 |
October | 22.78 | 11.70 |
November | 21.86 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 22.93 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F9 N2 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.72 | 2.70 |
March | 21.83 | 6.07 |
April | 23.05 | 11.58 |
May | 23.78 | 14.61 |
June | 24.19 | 19.78 |
July | 24.39 | 24.54 |
August | 24.23 | 21.22 |
September | 23.88 | 17.37 |
October | 22.77 | 11.70 |
November | 21.85 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 22.93 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.39 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F9 S1 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.86 | -1.7 |
February | 22.32 | 2.70 |
March | 22.73 | 6.07 |
April | 23.79 | 11.58 |
May | 24.11 | 14.61 |
June | 24.25 | 19.78 |
July | 24.37 | 24.54 |
August | 24.33 | 21.22 |
September | 24.26 | 17.37 |
October | 23.99 | 11.70 |
November | 22.60 | 4.05 |
December | 22.12 | 1.86 |
Annual Sum or Average | 23.40 | 11.20 |
Minimum of Months | 21.86 | -1.7 |
Maximum of Months | 24.37 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F9 S2 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.86 | -1.7 |
February | 22.31 | 2.70 |
March | 22.74 | 6.07 |
April | 23.79 | 11.58 |
May | 24.11 | 14.61 |
June | 24.25 | 19.78 |
July | 24.37 | 24.54 |
August | 24.33 | 21.22 |
September | 24.26 | 17.37 |
October | 23.99 | 11.70 |
November | 22.60 | 4.05 |
December | 22.12 | 1.86 |
Annual Sum or Average | 23.40 | 11.20 |
Minimum of Months | 21.86 | -1.7 |
Maximum of Months | 24.37 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: F9 CORRIDOR
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.51 | -1.7 |
February | 22.26 | 2.70 |
March | 22.89 | 6.07 |
April | 24.66 | 11.58 |
May | 25.46 | 14.61 |
June | 26.26 | 19.78 |
July | 26.80 | 24.54 |
August | 26.39 | 21.22 |
September | 25.79 | 17.37 |
October | 24.52 | 11.70 |
November | 22.52 | 4.05 |
December | 21.85 | 1.86 |
Annual Sum or Average | 24.25 | 11.20 |
Minimum of Months | 21.51 | -1.7 |
Maximum of Months | 26.80 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.83 | -1.7 |
February | 22.16 | 2.70 |
March | 22.43 | 6.07 |
April | 23.31 | 11.58 |
May | 23.82 | 14.61 |
June | 24.12 | 19.78 |
July | 24.35 | 24.54 |
August | 24.20 | 21.22 |
September | 24.02 | 17.37 |
October | 23.34 | 11.70 |
November | 22.26 | 4.05 |
December | 21.96 | 1.86 |
Annual Sum or Average | 23.16 | 11.20 |
Minimum of Months | 21.83 | -1.7 |
Maximum of Months | 24.35 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.80 | 2.70 |
March | 22.02 | 6.07 |
April | 22.99 | 11.58 |
May | 23.67 | 14.61 |
June | 24.09 | 19.78 |
July | 24.36 | 24.54 |
August | 24.11 | 21.22 |
September | 23.76 | 17.37 |
October | 22.73 | 11.70 |
November | 21.85 | 4.05 |
December | 21.72 | 1.86 |
Annual Sum or Average | 22.91 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.36 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.81 | -1.7 |
February | 22.13 | 2.70 |
March | 22.45 | 6.07 |
April | 23.34 | 11.58 |
May | 23.82 | 14.61 |
June | 24.15 | 19.78 |
July | 24.37 | 24.54 |
August | 24.21 | 21.22 |
September | 23.99 | 17.37 |
October | 23.35 | 11.70 |
November | 22.24 | 4.05 |
December | 21.94 | 1.86 |
Annual Sum or Average | 23.16 | 11.20 |
Minimum of Months | 21.81 | -1.7 |
Maximum of Months | 24.37 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.75 | 2.70 |
March | 21.96 | 6.07 |
April | 22.97 | 11.58 |
May | 23.60 | 14.61 |
June | 24.07 | 19.78 |
July | 24.36 | 24.54 |
August | 24.09 | 21.22 |
September | 23.69 | 17.37 |
October | 22.65 | 11.70 |
November | 21.81 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 22.87 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.36 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.75 | 2.70 |
March | 21.94 | 6.07 |
April | 22.94 | 11.58 |
May | 23.61 | 14.61 |
June | 24.08 | 19.78 |
July | 24.35 | 24.54 |
August | 24.09 | 21.22 |
September | 23.70 | 17.37 |
October | 22.65 | 11.70 |
November | 21.83 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 22.87 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.35 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -1.7 |
February | 21.75 | 2.70 |
March | 21.94 | 6.07 |
April | 22.94 | 11.58 |
May | 23.61 | 14.61 |
June | 24.08 | 19.78 |
July | 24.34 | 24.54 |
August | 24.09 | 21.22 |
September | 23.69 | 17.37 |
October | 22.65 | 11.70 |
November | 21.83 | 4.05 |
December | 21.70 | 1.86 |
Annual Sum or Average | 22.87 | 11.20 |
Minimum of Months | 21.70 | -1.7 |
Maximum of Months | 24.34 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.89 | -1.7 |
February | 22.26 | 2.70 |
March | 22.57 | 6.07 |
April | 23.47 | 11.58 |
May | 23.90 | 14.61 |
June | 24.15 | 19.78 |
July | 24.34 | 24.54 |
August | 24.23 | 21.22 |
September | 24.09 | 17.37 |
October | 23.57 | 11.70 |
November | 22.41 | 4.05 |
December | 22.04 | 1.86 |
Annual Sum or Average | 23.25 | 11.20 |
Minimum of Months | 21.89 | -1.7 |
Maximum of Months | 24.34 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.89 | -1.7 |
February | 22.26 | 2.70 |
March | 22.57 | 6.07 |
April | 23.48 | 11.58 |
May | 23.91 | 14.61 |
June | 24.16 | 19.78 |
July | 24.34 | 24.54 |
August | 24.24 | 21.22 |
September | 24.09 | 17.37 |
October | 23.57 | 11.70 |
November | 22.41 | 4.05 |
December | 22.04 | 1.86 |
Annual Sum or Average | 23.25 | 11.20 |
Minimum of Months | 21.89 | -1.7 |
Maximum of Months | 24.34 | 24.54 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2015-09-09 19:00:31
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.34 | -1.7 |
February | 22.25 | 2.70 |
March | 23.04 | 6.07 |
April | 24.97 | 11.58 |
May | 25.92 | 14.61 |
June | 26.94 | 19.78 |
July | 27.66 | 24.54 |
August | 27.05 | 21.22 |
September | 26.22 | 17.37 |
October | 24.63 | 11.70 |
November | 22.43 | 4.05 |
December | 21.72 | 1.86 |
Annual Sum or Average | 24.52 | 11.20 |
Minimum of Months | 21.34 | -1.7 |
Maximum of Months | 27.66 | 24.54 |
Report: COMPONENTS OF PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2015-09-09 19:00:31
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W] | |
January | 0.262606E+12 | 139736.770 | 10-JAN-19:00 | 14401.373 | 51749.961 | 23798.643 | 35696.000 | 0.000 | 10364.000 | 1965.768 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
February | 0.216350E+12 | 121093.789 | 13-FEB-19:00 | 14401.373 | 51749.961 | 23798.643 | 17053.019 | 0.000 | 10364.000 | 1965.768 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
March | 0.227100E+12 | 126806.700 | 31-MAR-16:15 | 11327.174 | 57142.088 | 23798.643 | 0.000 | 29554.040 | 0.000 | 1965.768 | 1023.790 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
April | 0.217706E+12 | 154844.220 | 13-APR-16:30 | 11327.174 | 57142.088 | 23798.643 | 0.000 | 56870.102 | 0.000 | 1965.768 | 1745.287 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
May | 0.232961E+12 | 161472.681 | 04-MAY-17:30 | 13120.457 | 57042.023 | 23798.643 | 0.000 | 61612.694 | 0.000 | 1965.768 | 1945.088 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
June | 0.263262E+12 | 168178.770 | 22-JUN-17:15 | 13120.457 | 57042.023 | 23798.643 | 0.000 | 68047.407 | 0.000 | 1965.768 | 2216.660 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
July | 0.305147E+12 | 171034.841 | 31-JUL-17:00 | 13120.457 | 57042.023 | 23798.643 | 0.000 | 70644.804 | 0.000 | 1965.768 | 2475.137 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.283288E+12 | 170622.957 | 08-AUG-17:15 | 13120.457 | 57042.023 | 23798.643 | 0.000 | 70518.397 | 0.000 | 1965.768 | 2189.857 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.249863E+12 | 164581.833 | 08-SEP-17:15 | 13120.457 | 57042.023 | 23798.643 | 0.000 | 64658.879 | 0.000 | 1965.768 | 2008.251 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
October | 0.231091E+12 | 162147.018 | 01-OCT-17:15 | 13120.457 | 57042.023 | 23798.643 | 0.000 | 62241.618 | 0.000 | 1965.768 | 1990.698 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
November | 0.229905E+12 | 133920.814 | 23-NOV-18:15 | 13120.457 | 57042.023 | 23798.643 | 25642.111 | 0.000 | 10364.000 | 1965.768 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
December | 0.250662E+12 | 147715.648 | 23-DEC-18:00 | 13120.457 | 57042.023 | 23798.643 | 39436.748 | 0.000 | 10364.000 | 1965.768 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.296994E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||||
Minimum of Months | 0.216350E+12 | 121093.789 | 11327.174 | 51749.961 | 23798.643 | 0.000 | 0.000 | 0.000 | 1965.768 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.305147E+12 | 171034.841 | 14401.373 | 57142.088 | 23798.643 | 39436.748 | 70644.804 | 10364.000 | 1965.768 | 2475.137 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: COMPONENTS OF PEAK GAS DEMAND
For: Meter
Timestamp: 2015-09-09 19:00:31
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC [Invalid/Undefined] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT {AT MAX/MIN} [W] | WATERSYSTEMS:GAS {AT MAX/MIN} [W] | WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.303153E+12 | 267957.603 | 04-JAN-08:15 | 0.000 | 0.000 | 0.000 | 267957.603 | 81201.356 | 81201.356 | 186756.247 |
February | 0.186941E+12 | 194383.791 | 15-FEB-10:00 | 0.000 | 0.000 | 0.000 | 194383.791 | 73643.478 | 73643.478 | 120740.313 |
March | 0.154841E+12 | 166511.067 | 11-MAR-06:15 | 0.000 | 0.000 | 0.000 | 166511.067 | 68345.559 | 68345.559 | 98165.507 |
April | 0.107252E+12 | 141063.680 | 08-APR-05:30 | 0.000 | 0.000 | 0.000 | 141063.680 | 76139.244 | 76139.244 | 64924.436 |
May | 0.986851E+11 | 79038.074 | 02-MAY-06:00 | 0.000 | 0.000 | 0.000 | 79038.074 | 79038.074 | 79038.074 | 0.000 |
June | 0.890697E+11 | 76557.588 | 02-JUN-06:00 | 0.000 | 0.000 | 0.000 | 76557.588 | 76557.588 | 76557.588 | 0.000 |
July | 0.872850E+11 | 74642.089 | 01-JUL-06:45 | 0.000 | 0.000 | 0.000 | 74642.089 | 74642.089 | 74642.089 | 0.000 |
August | 0.856397E+11 | 73643.506 | 31-AUG-06:45 | 0.000 | 0.000 | 0.000 | 73643.506 | 73643.506 | 73643.506 | 0.000 |
September | 0.848155E+11 | 74748.612 | 29-SEP-06:45 | 0.000 | 0.000 | 0.000 | 74748.612 | 74748.612 | 74748.612 | 0.000 |
October | 0.943345E+11 | 121879.495 | 26-OCT-07:15 | 0.000 | 0.000 | 0.000 | 121879.495 | 75941.551 | 75941.551 | 45937.944 |
November | 0.174059E+12 | 201952.020 | 24-NOV-06:30 | 0.000 | 0.000 | 0.000 | 201952.020 | 68342.665 | 68342.665 | 133609.356 |
December | 0.243482E+12 | 268387.144 | 28-DEC-08:15 | 0.000 | 0.000 | 0.000 | 268387.144 | 80520.398 | 80520.398 | 187866.747 |
Annual Sum or Average | 0.170956E+13 | 0.000 | 0.000 | 0.000 | ||||||
Minimum of Months | 0.848155E+11 | 73643.506 | 0.000 | 0.000 | 0.000 | 73643.506 | 68342.665 | 68342.665 | 0.000 | |
Maximum of Months | 0.303153E+12 | 268387.144 | 0.000 | 0.000 | 0.000 | 268387.144 | 81201.356 | 81201.356 | 187866.747 |