Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 19:10

Tabular Output Report in Format: HTML

Building: High-Rise Apartment

Environment: Houston Bush Intercontinental TX USA TMY3 WMO#=722430

Simulation Timestamp: 2015-09-09 19:11:57


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:57

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 4446.16 567.37 629.78
Net Site Energy 4446.16 567.37 629.78
Total Source Energy 11874.30 1515.26 1681.94
Net Source Energy 11874.30 1515.26 1681.94


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 7836.48
Net Conditioned Building Area 7059.89
Unconditioned Building Area 776.58


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 49.16 140.95 0.00 0.00 0.00 0.00
Cooling 924.90 0.00 0.00 0.00 0.00 0.00
Interior Lighting 296.56 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 162.86 0.00 0.00 0.00 0.00 0.00
Interior Equipment 1137.32 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 659.86 0.00 0.00 0.00 0.00 0.00
Pumps 73.12 0.00 0.00 0.00 0.00 0.00
Heat Rejection 46.83 0.00 0.00 0.00 0.00 2392.76
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 918.44 0.00 0.00 0.00 4778.51
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 3386.78 1059.39 0.00 0.00 0.00 7171.27
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating Boiler 0.00 140.95 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
  Other 49.16 0.00 0.00 0.00 0.00 0.00
Cooling General 924.90 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 242.55 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 54.01 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 162.86 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 1137.32 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 659.86 0.00 0.00 0.00 0.00 0.00
Pumps General 73.12 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 46.83 0.00 0.00 0.00 0.00 2392.76
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 918.44 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 4778.51
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 65.07 0.00 0.00 0.00 0.00 0.00
HVAC 248.43 150.06 0.00 0.00 0.00 1.02
Other 161.10 0.00 0.00 0.00 0.00 0.00
Total 479.72 150.06 0.00 0.00 0.00 1.02


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 58.63 0.00 0.00 0.00 0.00 0.00
HVAC 223.81 135.19 0.00 0.00 0.00 0.92
Other 145.13 0.00 0.00 0.00 0.00 0.00
Total 432.18 135.19 0.00 0.00 0.00 0.92


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 3386.78 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 3386.78 100.00
     
Total On-Site and Utility Electric Sources 3386.78 100.00
Total Electricity End Uses 3386.78 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 7171.27 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 7171.27 100.00
Total Water End Uses 7171.27 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 47.25
Time Setpoint Not Met During Occupied Cooling 313.50
Time Not Comfortable Based on Simple ASHRAE 55-2004 3681.50


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |

COMPONENTS OF PEAK ELECTRICAL DEMAND

| Meter |

COMPONENTS OF PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:57

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 19:10
RunPeriod Houston Bush Intercontinental TX USA TMY3 WMO#=722430
Weather File Houston Bush Intercontinental TX USA TMY3 WMO#=722430
Latitude [deg] 30.00
Longitude [deg] -95.4
Elevation [m] 29.00
Time Zone -6.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3855.02 1411.96 515.55 1411.96 515.55
Window Opening Area [m2] 1150.39 423.59 152.73 423.59 150.48
Window-Wall Ratio [%] 29.84 30.00 29.62 30.00 29.19


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3752.84 1411.96 464.46 1411.96 464.46
Window Opening Area [m2] 1125.85 423.59 139.34 423.59 139.34
Window-Wall Ratio [%] 30.00 30.00 30.00 30.00 30.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
OFFICE 88.25 Yes Yes 268.96 1.00 58.52 17.56 29.5362 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 4.47 6.7128   0.0000
F2 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F3 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F4 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
M SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
M CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 13.4255   0.0000
F6 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F7 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F8 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F9 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
T SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   264.3872
Total 7836.48     23884.04   3855.02 1150.39 4.3335 39.48 8.6291
Conditioned Total 7059.89     21517.16   3752.84 1125.85 3.9979 35.57 6.6700
Unconditioned Total 776.58     2366.87   102.18 24.54 7.3840   26.4387
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:57

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 04-AUG-17:15 11-FEB-06:45 - - - 02-AUG-17:15
Heating 0.00 205316.53 0.00 0.00 0.00 0.00
Cooling 90227.27 0.00 0.00 0.00 0.00 0.00
Interior Lighting 13120.46 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 57042.02 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 20924.02 0.00 0.00 0.00 0.00 0.00
Pumps 2453.60 0.00 0.00 0.00 0.00 0.00
Heat Rejection 3653.19 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 72689.02 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 189408.37 278005.55 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating Boiler 0.00 205316.53 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 90227.27 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 10541.04 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 2579.42 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 57042.02 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 20924.02 0.00 0.00 0.00 0.00 0.00
Pumps General 2453.60 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 3653.19 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 72689.02 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:57

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 155.68 152.78 0.00 0.00 0.00
Cooling 2929.16 0.00 0.00 0.00 0.00
Interior Lighting 939.20 0.00 0.00 0.00 0.00
Exterior Lighting 515.78 0.00 0.00 0.00 0.00
Interior Equipment 3601.91 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 2089.78 0.00 0.00 0.00 0.00
Pumps 231.56 0.00 0.00 0.00 0.00
Heat Rejection 148.30 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 995.59 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 10725.93 1148.37 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 22.05 21.64 0.00 0.00 0.00
Cooling 414.90 0.00 0.00 0.00 0.00
Interior Lighting 133.03 0.00 0.00 0.00 0.00
Exterior Lighting 73.06 0.00 0.00 0.00 0.00
Interior Equipment 510.19 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 296.01 0.00 0.00 0.00 0.00
Pumps 32.80 0.00 0.00 0.00 0.00
Heat Rejection 21.01 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 141.02 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1519.28 162.66 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 22.05 21.64 0.00 0.00 0.00
Cooling 414.90 0.00 0.00 0.00 0.00
Interior Lighting 133.03 0.00 0.00 0.00 0.00
Exterior Lighting 73.06 0.00 0.00 0.00 0.00
Interior Equipment 510.19 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 296.01 0.00 0.00 0.00 0.00
Pumps 32.80 0.00 0.00 0.00 0.00
Heat Rejection 21.01 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 141.02 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1519.28 162.66 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:57

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB -1.60 0.00 -1.60 Wetbulb [C] 2.80 0.00
HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 36.00 10.10 24.80 Wetbulb [C] 3.50 170.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:57

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 270.00 180.00  
F2 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F2 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F2 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F2 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F2 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F2 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F3 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F3 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F3 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F3 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F3 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F3 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F4 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F4 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F4 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F4 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F4 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F4 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
M WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F6 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F6 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F6 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F6 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F6 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F6 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F7 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F7 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F7 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F7 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F7 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F7 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F8 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F8 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F8 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F8 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F8 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F8 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F9 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F9 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F9 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F9 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F9 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F9 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.30 0.269 0.283 77.66 0.00 0.00  


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G SWALL SWA 180.00 90.00 S
GWINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No G WWALL SWA 270.00 90.00 W
GWINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G NWALL NWA 0.00 90.00 N
GWINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No G WWALL NWA 270.00 90.00 W
GWINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G SWALL SEA 180.00 90.00 S
GWINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No G EWALL SEA 90.00 90.00 E
GWINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G NWALL NEA 0.00 90.00 N
GWINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No G EWALL NEA 90.00 90.00 E
GWINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G NWALL N1A 0.00 90.00 N
GWINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G NWALL N2A 0.00 90.00 N
GWINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G SWALL S1A 180.00 90.00 S
GWINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No G SWALL S2A 180.00 90.00 S
GWINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No G WWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.72_SHGC_0.25 3.36 0.00 0.00 3.36 3.36 4.600 0.293 0.130     No G EWALL C 90.00 90.00 E
F2WINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F2 WWALL SWA 270.00 90.00 W
F2WINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 SWALL SWA 180.00 90.00 S
F2WINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 NWALL NWA 0.00 90.00 N
F2WINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F2 WWALL NWA 270.00 90.00 W
F2WINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F2 EWALL SEA 90.00 90.00 E
F2WINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 SWALL SEA 180.00 90.00 S
F2WINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 NWALL NEA 0.00 90.00 N
F2WINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F2 EWALL NEA 90.00 90.00 E
F2WINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 NWALL N1A 0.00 90.00 N
F2WINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 NWALL N2A 0.00 90.00 N
F2WINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 SWALL S1A 180.00 90.00 S
F2WINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F2 SWALL S2A 180.00 90.00 S
F2WINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F2 WWALL C 270.00 90.00 W
F2WINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F2 EWALL C 90.00 90.00 E
F3WINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F3 WWALL SWA 270.00 90.00 W
F3WINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 SWALL SWA 180.00 90.00 S
F3WINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 NWALL NWA 0.00 90.00 N
F3WINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F3 WWALL NWA 270.00 90.00 W
F3WINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F3 EWALL SEA 90.00 90.00 E
F3WINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 SWALL SEA 180.00 90.00 S
F3WINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 NWALL NEA 0.00 90.00 N
F3WINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F3 EWALL NEA 90.00 90.00 E
F3WINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 NWALL N1A 0.00 90.00 N
F3WINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 NWALL N2A 0.00 90.00 N
F3WINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 SWALL S1A 180.00 90.00 S
F3WINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F3 SWALL S2A 180.00 90.00 S
F3WINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F3 WWALL C 270.00 90.00 W
F3WINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F3 EWALL C 90.00 90.00 E
F4WINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F4 WWALL SWA 270.00 90.00 W
F4WINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 SWALL SWA 180.00 90.00 S
F4WINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 NWALL NWA 0.00 90.00 N
F4WINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F4 WWALL NWA 270.00 90.00 W
F4WINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F4 EWALL SEA 90.00 90.00 E
F4WINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 SWALL SEA 180.00 90.00 S
F4WINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 NWALL NEA 0.00 90.00 N
F4WINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F4 EWALL NEA 90.00 90.00 E
F4WINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 NWALL N1A 0.00 90.00 N
F4WINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 NWALL N2A 0.00 90.00 N
F4WINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 SWALL S1A 180.00 90.00 S
F4WINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F4 SWALL S2A 180.00 90.00 S
F4WINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F4 WWALL C 270.00 90.00 W
F4WINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F4 EWALL C 90.00 90.00 E
MWINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No M WWALL SWA 270.00 90.00 W
MWINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M SWALL SWA 180.00 90.00 S
MWINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M NWALL NWA 0.00 90.00 N
MWINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No M WWALL NWA 270.00 90.00 W
MWINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No M EWALL SEA 90.00 90.00 E
MWINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M SWALL SEA 180.00 90.00 S
MWINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M NWALL NEA 0.00 90.00 N
MWINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No M EWALL NEA 90.00 90.00 E
MWINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M NWALL N1A 0.00 90.00 N
MWINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M NWALL N2A 0.00 90.00 N
MWINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M SWALL S1A 180.00 90.00 S
MWINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No M SWALL S2A 180.00 90.00 S
MWINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No M WWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No M EWALL C 90.00 90.00 E
F6WINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F6 WWALL SWA 270.00 90.00 W
F6WINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 SWALL SWA 180.00 90.00 S
F6WINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 NWALL NWA 0.00 90.00 N
F6WINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F6 WWALL NWA 270.00 90.00 W
F6WINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F6 EWALL SEA 90.00 90.00 E
F6WINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 SWALL SEA 180.00 90.00 S
F6WINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 NWALL NEA 0.00 90.00 N
F6WINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F6 EWALL NEA 90.00 90.00 E
F6WINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 NWALL N1A 0.00 90.00 N
F6WINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 NWALL N2A 0.00 90.00 N
F6WINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 SWALL S1A 180.00 90.00 S
F6WINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F6 SWALL S2A 180.00 90.00 S
F6WINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F6 WWALL C 270.00 90.00 W
F6WINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F6 EWALL C 90.00 90.00 E
F7WINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F7 WWALL SWA 270.00 90.00 W
F7WINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 SWALL SWA 180.00 90.00 S
F7WINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 NWALL NWA 0.00 90.00 N
F7WINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F7 WWALL NWA 270.00 90.00 W
F7WINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F7 EWALL SEA 90.00 90.00 E
F7WINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 SWALL SEA 180.00 90.00 S
F7WINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 NWALL NEA 0.00 90.00 N
F7WINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F7 EWALL NEA 90.00 90.00 E
F7WINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 NWALL N1A 0.00 90.00 N
F7WINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 NWALL N2A 0.00 90.00 N
F7WINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 SWALL S1A 180.00 90.00 S
F7WINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F7 SWALL S2A 180.00 90.00 S
F7WINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F7 WWALL C 270.00 90.00 W
F7WINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F7 EWALL C 90.00 90.00 E
F8WINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F8 WWALL SWA 270.00 90.00 W
F8WINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 SWALL SWA 180.00 90.00 S
F8WINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 NWALL NWA 0.00 90.00 N
F8WINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F8 WWALL NWA 270.00 90.00 W
F8WINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F8 EWALL SEA 90.00 90.00 E
F8WINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 SWALL SEA 180.00 90.00 S
F8WINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 NWALL NEA 0.00 90.00 N
F8WINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F8 EWALL NEA 90.00 90.00 E
F8WINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 NWALL N1A 0.00 90.00 N
F8WINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 NWALL N2A 0.00 90.00 N
F8WINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 SWALL S1A 180.00 90.00 S
F8WINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F8 SWALL S2A 180.00 90.00 S
F8WINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F8 WWALL C 270.00 90.00 W
F8WINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F8 EWALL C 90.00 90.00 E
F9WINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F9 WWALL SWA 270.00 90.00 W
F9WINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 SWALL SWA 180.00 90.00 S
F9WINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 NWALL NWA 0.00 90.00 N
F9WINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F9 WWALL NWA 270.00 90.00 W
F9WINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F9 EWALL SEA 90.00 90.00 E
F9WINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 SWALL SEA 180.00 90.00 S
F9WINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 NWALL NEA 0.00 90.00 N
F9WINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No F9 EWALL NEA 90.00 90.00 E
F9WINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 NWALL N1A 0.00 90.00 N
F9WINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 NWALL N2A 0.00 90.00 N
F9WINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 SWALL S1A 180.00 90.00 S
F9WINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No F9 SWALL S2A 180.00 90.00 S
F9WINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F9 WWALL C 270.00 90.00 W
F9WINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No F9 EWALL C 90.00 90.00 E
TWINDOW2 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No T WWALL SWA 270.00 90.00 W
TWINDOW3 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T SWALL SWA 180.00 90.00 S
TWINDOW4 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T NWALL NWA 0.00 90.00 N
TWINDOW6 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No T WWALL NWA 270.00 90.00 W
TWINDOW8 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No T EWALL SEA 90.00 90.00 E
TWINDOW1 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T SWALL SEA 180.00 90.00 S
TWINDOW5 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T NWALL NEA 0.00 90.00 N
TWINDOW7 WINDOW_U_0.72_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 4.600 0.293 0.130     No T EWALL NEA 90.00 90.00 E
TWINDOW9 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T NWALL N1A 0.00 90.00 N
TWINDOW10 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T NWALL N2A 0.00 90.00 N
TWINDOW11 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T SWALL S1A 180.00 90.00 S
TWINDOW12 WINDOW_U_0.72_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 4.600 0.293 0.130     No T SWALL S2A 180.00 90.00 S
TWINDOW13 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No T WWALL C 270.00 90.00 W
TWINDOW14 WINDOW_U_0.72_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 4.600 0.293 0.130     No T EWALL C 90.00 90.00 E
Total or Average           1150.39 4.600 0.293 0.130              
North Total or Average           423.59 4.600 0.293 0.130              
Non-North Total or Average           726.80 4.600 0.293 0.130              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:57

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW3 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
GWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW4 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
GWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
GWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW5 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
GWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW9 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
GWINDOW10 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
GWINDOW11 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
GWINDOW12 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
GWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW3 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW4 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW1 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW5 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW9 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW10 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW11 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW12 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW3 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW4 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW1 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW5 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW9 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW10 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW11 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW12 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW3 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW4 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW1 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW5 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW9 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW10 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW11 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW12 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW3 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
MWINDOW4 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
MWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
MWINDOW5 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
MWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW9 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
MWINDOW10 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
MWINDOW11 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
MWINDOW12 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
MWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW3 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW4 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW1 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW5 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW9 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW10 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW11 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW12 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW3 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW4 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW1 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW5 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW9 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW10 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW11 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW12 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW3 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW4 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW1 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW5 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW9 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW10 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW11 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW12 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW3 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW4 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW1 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW5 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW9 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW10 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW11 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW12 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW3 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
TWINDOW4 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
TWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
TWINDOW5 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
TWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW9 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
TWINDOW10 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
TWINDOW11 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
TWINDOW12 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
TWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:57

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
G SW APARTMENT_LIGHTS_HARDWIRED G SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G NW APARTMENT_LIGHTS_HARDWIRED G NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
OFFICE_LIGHTS_HARDWIRED OFFICE 14.7681 88.25 1303.26 GeneralLights LTG_OFF_SCH 62.05 168.00 61.07 0.0000 Y 14.94
G NE APARTMENT_LIGHTS_HARDWIRED G NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G N1 APARTMENT_LIGHTS_HARDWIRED G N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G N2 APARTMENT_LIGHTS_HARDWIRED G N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G S1 APARTMENT_LIGHTS_HARDWIRED G S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G S2 APARTMENT_LIGHTS_HARDWIRED G S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G CORRIDOR_LIGHTS_HARDWIRED G CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F2 SW APARTMENT_LIGHTS_HARDWIRED F2 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 NW APARTMENT_LIGHTS_HARDWIRED F2 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 SE APARTMENT_LIGHTS_HARDWIRED F2 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 NE APARTMENT_LIGHTS_HARDWIRED F2 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 N1 APARTMENT_LIGHTS_HARDWIRED F2 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 N2 APARTMENT_LIGHTS_HARDWIRED F2 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 S1 APARTMENT_LIGHTS_HARDWIRED F2 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 S2 APARTMENT_LIGHTS_HARDWIRED F2 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 CORRIDOR_LIGHTS_HARDWIRED F2 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F3 SW APARTMENT_LIGHTS_HARDWIRED F3 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 NW APARTMENT_LIGHTS_HARDWIRED F3 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 SE APARTMENT_LIGHTS_HARDWIRED F3 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 NE APARTMENT_LIGHTS_HARDWIRED F3 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 N1 APARTMENT_LIGHTS_HARDWIRED F3 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 N2 APARTMENT_LIGHTS_HARDWIRED F3 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 S1 APARTMENT_LIGHTS_HARDWIRED F3 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 S2 APARTMENT_LIGHTS_HARDWIRED F3 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 CORRIDOR_LIGHTS_HARDWIRED F3 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F4 SW APARTMENT_LIGHTS_HARDWIRED F4 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 NW APARTMENT_LIGHTS_HARDWIRED F4 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 SE APARTMENT_LIGHTS_HARDWIRED F4 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 NE APARTMENT_LIGHTS_HARDWIRED F4 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 N1 APARTMENT_LIGHTS_HARDWIRED F4 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 N2 APARTMENT_LIGHTS_HARDWIRED F4 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 S1 APARTMENT_LIGHTS_HARDWIRED F4 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 S2 APARTMENT_LIGHTS_HARDWIRED F4 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 CORRIDOR_LIGHTS_HARDWIRED F4 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
M SW APARTMENT_LIGHTS_HARDWIRED M SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M NW APARTMENT_LIGHTS_HARDWIRED M NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M SE APARTMENT_LIGHTS_HARDWIRED M SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M NE APARTMENT_LIGHTS_HARDWIRED M NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M N1 APARTMENT_LIGHTS_HARDWIRED M N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M N2 APARTMENT_LIGHTS_HARDWIRED M N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M S1 APARTMENT_LIGHTS_HARDWIRED M S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M S2 APARTMENT_LIGHTS_HARDWIRED M S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M CORRIDOR_LIGHTS_HARDWIRED M CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F6 SW APARTMENT_LIGHTS_HARDWIRED F6 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 NW APARTMENT_LIGHTS_HARDWIRED F6 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 SE APARTMENT_LIGHTS_HARDWIRED F6 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 NE APARTMENT_LIGHTS_HARDWIRED F6 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 N1 APARTMENT_LIGHTS_HARDWIRED F6 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 N2 APARTMENT_LIGHTS_HARDWIRED F6 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 S1 APARTMENT_LIGHTS_HARDWIRED F6 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 S2 APARTMENT_LIGHTS_HARDWIRED F6 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 CORRIDOR_LIGHTS_HARDWIRED F6 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F7 SW APARTMENT_LIGHTS_HARDWIRED F7 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 NW APARTMENT_LIGHTS_HARDWIRED F7 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 SE APARTMENT_LIGHTS_HARDWIRED F7 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 NE APARTMENT_LIGHTS_HARDWIRED F7 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 N1 APARTMENT_LIGHTS_HARDWIRED F7 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 N2 APARTMENT_LIGHTS_HARDWIRED F7 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 S1 APARTMENT_LIGHTS_HARDWIRED F7 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 S2 APARTMENT_LIGHTS_HARDWIRED F7 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 CORRIDOR_LIGHTS_HARDWIRED F7 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F8 SW APARTMENT_LIGHTS_HARDWIRED F8 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 NW APARTMENT_LIGHTS_HARDWIRED F8 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 SE APARTMENT_LIGHTS_HARDWIRED F8 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 NE APARTMENT_LIGHTS_HARDWIRED F8 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 N1 APARTMENT_LIGHTS_HARDWIRED F8 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 N2 APARTMENT_LIGHTS_HARDWIRED F8 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 S1 APARTMENT_LIGHTS_HARDWIRED F8 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 S2 APARTMENT_LIGHTS_HARDWIRED F8 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 CORRIDOR_LIGHTS_HARDWIRED F8 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F9 SW APARTMENT_LIGHTS_HARDWIRED F9 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 NW APARTMENT_LIGHTS_HARDWIRED F9 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 SE APARTMENT_LIGHTS_HARDWIRED F9 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 NE APARTMENT_LIGHTS_HARDWIRED F9 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 N1 APARTMENT_LIGHTS_HARDWIRED F9 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 N2 APARTMENT_LIGHTS_HARDWIRED F9 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 S1 APARTMENT_LIGHTS_HARDWIRED F9 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 S2 APARTMENT_LIGHTS_HARDWIRED F9 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 CORRIDOR_LIGHTS_HARDWIRED F9 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
T SW APARTMENT_LIGHTS_HARDWIRED T SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T NW APARTMENT_LIGHTS_HARDWIRED T NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T SE APARTMENT_LIGHTS_HARDWIRED T SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T NE APARTMENT_LIGHTS_HARDWIRED T NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T N1 APARTMENT_LIGHTS_HARDWIRED T N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T N2 APARTMENT_LIGHTS_HARDWIRED T N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T S1 APARTMENT_LIGHTS_HARDWIRED T S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T S2 APARTMENT_LIGHTS_HARDWIRED T S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T CORRIDOR_LIGHTS_HARDWIRED T CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
G SW APARTMENT_LIGHTS_PLUGIN G SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G NW APARTMENT_LIGHTS_PLUGIN G NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
OFFICE_LIGHTS_PLUGIN OFFICE 14.7681 88.25 1303.26 GeneralLights-plugin LTG_OFF_SCH 62.05 168.00 61.07 0.0000 Y 14.94
G NE APARTMENT_LIGHTS_PLUGIN G NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G N1 APARTMENT_LIGHTS_PLUGIN G N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G N2 APARTMENT_LIGHTS_PLUGIN G N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G S1 APARTMENT_LIGHTS_PLUGIN G S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G S2 APARTMENT_LIGHTS_PLUGIN G S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 SW APARTMENT_LIGHTS_PLUGIN F2 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 NW APARTMENT_LIGHTS_PLUGIN F2 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 SE APARTMENT_LIGHTS_PLUGIN F2 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 NE APARTMENT_LIGHTS_PLUGIN F2 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 N1 APARTMENT_LIGHTS_PLUGIN F2 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 N2 APARTMENT_LIGHTS_PLUGIN F2 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 S1 APARTMENT_LIGHTS_PLUGIN F2 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 S2 APARTMENT_LIGHTS_PLUGIN F2 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 SW APARTMENT_LIGHTS_PLUGIN F3 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 NW APARTMENT_LIGHTS_PLUGIN F3 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 SE APARTMENT_LIGHTS_PLUGIN F3 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 NE APARTMENT_LIGHTS_PLUGIN F3 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 N1 APARTMENT_LIGHTS_PLUGIN F3 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 N2 APARTMENT_LIGHTS_PLUGIN F3 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 S1 APARTMENT_LIGHTS_PLUGIN F3 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 S2 APARTMENT_LIGHTS_PLUGIN F3 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 SW APARTMENT_LIGHTS_PLUGIN F4 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 NW APARTMENT_LIGHTS_PLUGIN F4 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 SE APARTMENT_LIGHTS_PLUGIN F4 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 NE APARTMENT_LIGHTS_PLUGIN F4 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 N1 APARTMENT_LIGHTS_PLUGIN F4 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 N2 APARTMENT_LIGHTS_PLUGIN F4 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 S1 APARTMENT_LIGHTS_PLUGIN F4 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 S2 APARTMENT_LIGHTS_PLUGIN F4 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M SW APARTMENT_LIGHTS_PLUGIN M SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M NW APARTMENT_LIGHTS_PLUGIN M NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M SE APARTMENT_LIGHTS_PLUGIN M SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M NE APARTMENT_LIGHTS_PLUGIN M NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M N1 APARTMENT_LIGHTS_PLUGIN M N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M N2 APARTMENT_LIGHTS_PLUGIN M N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M S1 APARTMENT_LIGHTS_PLUGIN M S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M S2 APARTMENT_LIGHTS_PLUGIN M S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M CORRIDOR_LIGHTS_PLUGIN M CORRIDOR 6.7128 77.66 521.30 GeneralLights-plugin LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F6 SW APARTMENT_LIGHTS_PLUGIN F6 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 NW APARTMENT_LIGHTS_PLUGIN F6 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 SE APARTMENT_LIGHTS_PLUGIN F6 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 NE APARTMENT_LIGHTS_PLUGIN F6 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 N1 APARTMENT_LIGHTS_PLUGIN F6 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 N2 APARTMENT_LIGHTS_PLUGIN F6 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 S1 APARTMENT_LIGHTS_PLUGIN F6 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 S2 APARTMENT_LIGHTS_PLUGIN F6 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 SW APARTMENT_LIGHTS_PLUGIN F7 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 NW APARTMENT_LIGHTS_PLUGIN F7 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 SE APARTMENT_LIGHTS_PLUGIN F7 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 NE APARTMENT_LIGHTS_PLUGIN F7 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 N1 APARTMENT_LIGHTS_PLUGIN F7 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 N2 APARTMENT_LIGHTS_PLUGIN F7 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 S1 APARTMENT_LIGHTS_PLUGIN F7 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 S2 APARTMENT_LIGHTS_PLUGIN F7 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 SW APARTMENT_LIGHTS_PLUGIN F8 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 NW APARTMENT_LIGHTS_PLUGIN F8 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 SE APARTMENT_LIGHTS_PLUGIN F8 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 NE APARTMENT_LIGHTS_PLUGIN F8 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 N1 APARTMENT_LIGHTS_PLUGIN F8 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 N2 APARTMENT_LIGHTS_PLUGIN F8 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 S1 APARTMENT_LIGHTS_PLUGIN F8 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 S2 APARTMENT_LIGHTS_PLUGIN F8 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 SW APARTMENT_LIGHTS_PLUGIN F9 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 NW APARTMENT_LIGHTS_PLUGIN F9 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 SE APARTMENT_LIGHTS_PLUGIN F9 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 NE APARTMENT_LIGHTS_PLUGIN F9 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 N1 APARTMENT_LIGHTS_PLUGIN F9 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 N2 APARTMENT_LIGHTS_PLUGIN F9 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 S1 APARTMENT_LIGHTS_PLUGIN F9 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 S2 APARTMENT_LIGHTS_PLUGIN F9 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T SW APARTMENT_LIGHTS_PLUGIN T SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T NW APARTMENT_LIGHTS_PLUGIN T NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T SE APARTMENT_LIGHTS_PLUGIN T SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T NE APARTMENT_LIGHTS_PLUGIN T NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T N1 APARTMENT_LIGHTS_PLUGIN T N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T N2 APARTMENT_LIGHTS_PLUGIN T N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T S1 APARTMENT_LIGHTS_PLUGIN T S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T S2 APARTMENT_LIGHTS_PLUGIN T S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
Interior Lighting Total   2.2679 14974.03 33959.19               296.56


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 10364.00 AstronomicalClock -   83.71 83.71 162.86
Exterior Lighting Total 10364.00           162.86



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:57

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
CENTRAL BOILER Boiler:HotWater 347922.84 0.75    
CENTRAL TOWER EvaporativeFluidCooler:SingleSpeed 278338.27      


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
HEAT PUMP COOLING MODE AIRLOOP G SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4608.67 3128.39 1480.28 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4679.76 3185.09 1494.67 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP OFFICE Coil:Cooling:WaterToAirHeatPump:EquationFit   6206.62 4237.38 1969.23 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3858.00 2571.04 1286.96 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2735.61 1742.48 993.13 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2719.38 1730.42 988.96 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2760.70 1745.35 1015.35 0.63 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2844.61 1808.67 1035.94 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5325.85 3639.85 1686.00 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5397.15 3694.82 1702.33 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4908.14 3327.10 1581.04 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4499.55 3022.68 1476.86 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3205.84 2075.61 1130.23 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3193.10 2066.10 1127.01 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3237.26 2085.92 1151.34 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3265.91 2107.62 1158.29 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5394.79 3668.54 1726.25 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5468.75 3725.42 1743.33 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4696.98 3143.00 1553.98 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4576.48 3058.90 1517.58 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3272.61 2114.19 1158.43 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3259.96 2104.76 1155.20 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3308.04 2127.80 1180.24 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3319.52 2136.49 1183.02 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5451.62 3694.22 1757.40 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5524.82 3750.42 1774.40 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4718.56 3142.93 1575.63 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4633.39 3083.82 1549.57 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3320.05 2141.18 1178.87 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3307.46 2131.82 1175.64 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3354.28 2154.07 1200.22 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3363.09 2160.73 1202.35 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5526.84 3737.31 1789.53 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5600.46 3793.75 1806.71 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4785.39 3180.37 1605.01 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4703.28 3123.64 1579.65 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3387.85 2185.00 1202.85 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3375.33 2175.71 1199.62 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3419.96 2196.49 1223.47 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3428.32 2202.82 1225.51 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5523.95 3721.49 1802.46 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5590.33 3773.87 1816.45 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4772.72 3159.74 1612.98 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4688.82 3101.74 1587.08 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3372.72 2167.85 1204.86 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3360.28 2158.65 1201.63 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3405.06 2179.51 1225.55 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3413.32 2185.74 1227.58 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5540.59 3723.67 1816.92 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5606.28 3775.47 1830.81 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4785.33 3159.70 1625.63 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4700.78 3101.28 1599.49 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3383.77 2171.06 1212.70 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3371.40 2161.93 1209.47 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3415.24 2182.10 1233.14 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3423.44 2188.28 1235.16 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5574.45 3740.09 1834.36 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5639.71 3791.51 1848.20 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4815.18 3173.73 1641.45 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4729.75 3114.70 1615.05 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3413.26 2188.54 1224.72 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3400.99 2179.49 1221.50 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3442.85 2198.25 1244.59 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3451.01 2204.39 1246.61 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5733.40 3853.76 1879.65 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5807.39 3910.27 1897.13 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4908.53 3236.15 1672.38 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4818.08 3173.35 1644.73 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3567.04 2298.80 1268.24 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3554.79 2289.74 1265.05 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3560.38 2281.19 1279.19 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3568.40 2287.23 1281.17 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SW Coil:Cooling:WaterToAirHeatPump:EquationFit   6798.46 4655.54 2142.92 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NW Coil:Cooling:WaterToAirHeatPump:EquationFit   6785.88 4646.86 2139.02 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SE Coil:Cooling:WaterToAirHeatPump:EquationFit   5913.18 3973.93 1939.25 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NE Coil:Cooling:WaterToAirHeatPump:EquationFit   5693.60 3821.80 1871.80 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   4423.93 2927.63 1496.30 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   4423.44 2927.36 1496.08 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   4699.16 3136.60 1562.55 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   4706.44 3142.23 1564.22 0.67 0.00    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
None            


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
HEAT PUMP HEATING MODE AIRLOOP G SW Coil:Heating:WaterToAirHeatPump:EquationFit   4608.67 0.00
HEAT PUMP HEATING MODE AIRLOOP G NW Coil:Heating:WaterToAirHeatPump:EquationFit   4679.76 0.00
HEAT PUMP HEATING MODE AIRLOOP OFFICE Coil:Heating:WaterToAirHeatPump:EquationFit   6206.62 0.00
HEAT PUMP HEATING MODE AIRLOOP G NE Coil:Heating:WaterToAirHeatPump:EquationFit   3858.00 0.00
HEAT PUMP HEATING MODE AIRLOOP G N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2735.61 0.00
HEAT PUMP HEATING MODE AIRLOOP G N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2719.38 0.00
HEAT PUMP HEATING MODE AIRLOOP G S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2760.70 0.00
HEAT PUMP HEATING MODE AIRLOOP G S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2844.61 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5325.85 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NW Coil:Heating:WaterToAirHeatPump:EquationFit   5397.15 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4908.14 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4499.55 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3205.84 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3193.10 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3237.26 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3265.91 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5394.79 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NW Coil:Heating:WaterToAirHeatPump:EquationFit   5468.75 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4696.98 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4576.48 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3272.61 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3259.96 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3308.04 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3319.52 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5451.62 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NW Coil:Heating:WaterToAirHeatPump:EquationFit   5524.82 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4718.56 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4633.39 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3320.05 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3307.46 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3354.28 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3363.09 0.00
HEAT PUMP HEATING MODE AIRLOOP M SW Coil:Heating:WaterToAirHeatPump:EquationFit   5526.84 0.00
HEAT PUMP HEATING MODE AIRLOOP M NW Coil:Heating:WaterToAirHeatPump:EquationFit   5600.46 0.00
HEAT PUMP HEATING MODE AIRLOOP M SE Coil:Heating:WaterToAirHeatPump:EquationFit   4785.39 0.00
HEAT PUMP HEATING MODE AIRLOOP M NE Coil:Heating:WaterToAirHeatPump:EquationFit   4703.28 0.00
HEAT PUMP HEATING MODE AIRLOOP M N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3387.85 0.00
HEAT PUMP HEATING MODE AIRLOOP M N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3375.33 0.00
HEAT PUMP HEATING MODE AIRLOOP M S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3419.96 0.00
HEAT PUMP HEATING MODE AIRLOOP M S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3428.32 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5523.95 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NW Coil:Heating:WaterToAirHeatPump:EquationFit   5590.33 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4772.72 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4688.82 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3372.72 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3360.28 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3405.06 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3413.32 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5540.59 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NW Coil:Heating:WaterToAirHeatPump:EquationFit   5606.28 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4785.33 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4700.78 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3383.77 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3371.40 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3415.24 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3423.44 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5574.45 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NW Coil:Heating:WaterToAirHeatPump:EquationFit   5639.71 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4815.18 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4729.75 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3413.26 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3400.99 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3442.85 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3451.01 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5733.40 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NW Coil:Heating:WaterToAirHeatPump:EquationFit   5807.39 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4908.53 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NE Coil:Heating:WaterToAirHeatPump:EquationFit   4818.08 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3567.04 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3554.79 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3560.38 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3568.40 0.00
HEAT PUMP HEATING MODE AIRLOOP T SW Coil:Heating:WaterToAirHeatPump:EquationFit   6798.46 0.00
HEAT PUMP HEATING MODE AIRLOOP T NW Coil:Heating:WaterToAirHeatPump:EquationFit   6785.88 0.00
HEAT PUMP HEATING MODE AIRLOOP T SE Coil:Heating:WaterToAirHeatPump:EquationFit   5913.18 0.00
HEAT PUMP HEATING MODE AIRLOOP T NE Coil:Heating:WaterToAirHeatPump:EquationFit   5693.60 0.00
HEAT PUMP HEATING MODE AIRLOOP T N1 Coil:Heating:WaterToAirHeatPump:EquationFit   4423.93 0.00
HEAT PUMP HEATING MODE AIRLOOP T N2 Coil:Heating:WaterToAirHeatPump:EquationFit   4423.44 0.00
HEAT PUMP HEATING MODE AIRLOOP T S1 Coil:Heating:WaterToAirHeatPump:EquationFit   4699.16 0.00
HEAT PUMP HEATING MODE AIRLOOP T S2 Coil:Heating:WaterToAirHeatPump:EquationFit   4706.44 0.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW Coil:Heating:Electric   2729.40 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW Coil:Heating:Electric   2722.15 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE Coil:Heating:Electric   3402.45 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE Coil:Heating:Electric   2722.15 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 Coil:Heating:Electric   1969.25 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 Coil:Heating:Electric   1969.25 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 Coil:Heating:Electric   1974.32 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 Coil:Heating:Electric   1980.66 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW Coil:Heating:Electric   2721.67 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW Coil:Heating:Electric   2714.59 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE Coil:Heating:Electric   2740.79 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE Coil:Heating:Electric   2714.59 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 Coil:Heating:Electric   1811.93 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 Coil:Heating:Electric   1811.93 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 Coil:Heating:Electric   1821.83 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 Coil:Heating:Electric   1823.15 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW Coil:Heating:Electric   2745.26 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW Coil:Heating:Electric   2741.58 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE Coil:Heating:Electric   2747.49 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE Coil:Heating:Electric   2741.58 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 Coil:Heating:Electric   1797.72 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 Coil:Heating:Electric   1797.72 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 Coil:Heating:Electric   1802.04 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 Coil:Heating:Electric   1802.26 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW Coil:Heating:Electric   2802.27 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW Coil:Heating:Electric   2801.60 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE Coil:Heating:Electric   2802.52 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE Coil:Heating:Electric   2801.60 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 Coil:Heating:Electric   1824.72 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 Coil:Heating:Electric   1824.72 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 Coil:Heating:Electric   1825.72 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 Coil:Heating:Electric   1825.75 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW Coil:Heating:Electric   2837.60 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW Coil:Heating:Electric   2838.34 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE Coil:Heating:Electric   2837.63 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE Coil:Heating:Electric   2838.34 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 Coil:Heating:Electric   1835.93 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 Coil:Heating:Electric   1835.93 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 Coil:Heating:Electric   1835.43 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 Coil:Heating:Electric   1835.43 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW Coil:Heating:Electric   2926.03 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW Coil:Heating:Electric   2929.62 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE Coil:Heating:Electric   2926.04 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE Coil:Heating:Electric   2929.62 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 Coil:Heating:Electric   1902.67 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 Coil:Heating:Electric   1902.67 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 Coil:Heating:Electric   1899.30 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 Coil:Heating:Electric   1899.30 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW Coil:Heating:Electric   2989.08 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW Coil:Heating:Electric   2994.24 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE Coil:Heating:Electric   2989.08 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE Coil:Heating:Electric   2994.24 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 Coil:Heating:Electric   1947.11 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 Coil:Heating:Electric   1947.11 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 Coil:Heating:Electric   1942.14 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 Coil:Heating:Electric   1942.14 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW Coil:Heating:Electric   3053.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW Coil:Heating:Electric   3060.05 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE Coil:Heating:Electric   3053.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE Coil:Heating:Electric   3060.05 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 Coil:Heating:Electric   1994.93 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 Coil:Heating:Electric   1994.93 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 Coil:Heating:Electric   1988.72 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 Coil:Heating:Electric   1988.72 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW Coil:Heating:Electric   3215.62 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW Coil:Heating:Electric   3221.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE Coil:Heating:Electric   3215.62 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE Coil:Heating:Electric   3221.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 Coil:Heating:Electric   2132.63 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 Coil:Heating:Electric   2132.63 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 Coil:Heating:Electric   2126.92 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 Coil:Heating:Electric   2126.92 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW Coil:Heating:Electric   3713.56 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW Coil:Heating:Electric   3724.56 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE Coil:Heating:Electric   3713.56 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE Coil:Heating:Electric   3724.56 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 Coil:Heating:Electric   2666.51 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 Coil:Heating:Electric   2666.51 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 Coil:Heating:Electric   2654.60 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 Coil:Heating:Electric   2654.60 1.00


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
AIRLOOP G SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 293.09 1160.84 1.00 General
AIRLOOP G NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 299.80 1160.84 1.00 General
AIRLOOP OFFICE SUPPLY FAN Fan:OnOff 0.54 622.50 0.34 399.77 1160.84 1.00 General
AIRLOOP G NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 237.10 1160.84 1.00 General
AIRLOOP G N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 150.99 1160.84 1.00 General
AIRLOOP G N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 149.73 1160.84 1.00 General
AIRLOOP G S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 148.47 1160.84 1.00 General
AIRLOOP G S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 155.12 1160.84 1.00 General
AIRLOOP F2 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 344.55 1160.84 1.00 General
AIRLOOP F2 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 350.81 1160.84 1.00 General
AIRLOOP F2 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.27 312.74 1160.84 1.00 General
AIRLOOP F2 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 282.02 1160.84 1.00 General
AIRLOOP F2 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 184.15 1160.84 1.00 General
AIRLOOP F2 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 183.15 1160.84 1.00 General
AIRLOOP F2 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 182.57 1160.84 1.00 General
AIRLOOP F2 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 184.86 1160.84 1.00 General
AIRLOOP F3 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 345.84 1160.84 1.00 General
AIRLOOP F3 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 352.29 1160.84 1.00 General
AIRLOOP F3 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 291.52 1160.84 1.00 General
AIRLOOP F3 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 284.12 1160.84 1.00 General
AIRLOOP F3 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 187.19 1160.84 1.00 General
AIRLOOP F3 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 186.20 1160.84 1.00 General
AIRLOOP F3 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 185.98 1160.84 1.00 General
AIRLOOP F3 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 186.90 1160.84 1.00 General
AIRLOOP F4 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 347.24 1160.84 1.00 General
AIRLOOP F4 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 353.62 1160.84 1.00 General
AIRLOOP F4 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 290.22 1160.84 1.00 General
AIRLOOP F4 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 285.00 1160.84 1.00 General
AIRLOOP F4 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 189.27 1160.84 1.00 General
AIRLOOP F4 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 188.29 1160.84 1.00 General
AIRLOOP F4 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 187.99 1160.84 1.00 General
AIRLOOP F4 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 188.70 1160.84 1.00 General
AIRLOOP M SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 350.73 1160.84 1.00 General
AIRLOOP M NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 357.12 1160.84 1.00 General
AIRLOOP M SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 293.12 1160.84 1.00 General
AIRLOOP M NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 288.15 1160.84 1.00 General
AIRLOOP M N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 193.26 1160.84 1.00 General
AIRLOOP M N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 192.29 1160.84 1.00 General
AIRLOOP M S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 191.84 1160.84 1.00 General
AIRLOOP M S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 192.51 1160.84 1.00 General
AIRLOOP F6 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 347.86 1160.84 1.00 General
AIRLOOP F6 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 354.11 1160.84 1.00 General
AIRLOOP F6 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 290.04 1160.84 1.00 General
AIRLOOP F6 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 284.94 1160.84 1.00 General
AIRLOOP F6 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 190.92 1160.84 1.00 General
AIRLOOP F6 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 189.96 1160.84 1.00 General
AIRLOOP F6 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 189.54 1160.84 1.00 General
AIRLOOP F6 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 190.20 1160.84 1.00 General
AIRLOOP F7 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 347.29 1160.84 1.00 General
AIRLOOP F7 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 353.47 1160.84 1.00 General
AIRLOOP F7 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 289.25 1160.84 1.00 General
AIRLOOP F7 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 284.10 1160.84 1.00 General
AIRLOOP F7 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 190.79 1160.84 1.00 General
AIRLOOP F7 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 189.84 1160.84 1.00 General
AIRLOOP F7 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 189.35 1160.84 1.00 General
AIRLOOP F7 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 190.01 1160.84 1.00 General
AIRLOOP F8 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 348.30 1160.84 1.00 General
AIRLOOP F8 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 354.44 1160.84 1.00 General
AIRLOOP F8 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 290.03 1160.84 1.00 General
AIRLOOP F8 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 284.82 1160.84 1.00 General
AIRLOOP F8 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 192.21 1160.84 1.00 General
AIRLOOP F8 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 191.27 1160.84 1.00 General
AIRLOOP F8 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 190.64 1160.84 1.00 General
AIRLOOP F8 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 191.29 1160.84 1.00 General
AIRLOOP F9 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 359.92 1160.84 1.00 General
AIRLOOP F9 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 366.32 1160.84 1.00 General
AIRLOOP F9 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 295.96 1160.84 1.00 General
AIRLOOP F9 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 290.35 1160.84 1.00 General
AIRLOOP F9 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 203.42 1160.84 1.00 General
AIRLOOP F9 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 202.48 1160.84 1.00 General
AIRLOOP F9 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 198.83 1160.84 1.00 General
AIRLOOP F9 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 199.47 1160.84 1.00 General
AIRLOOP T SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.38 443.53 1160.84 1.00 General
AIRLOOP T NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.38 442.86 1160.84 1.00 General
AIRLOOP T SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 370.31 1160.84 1.00 General
AIRLOOP T NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 357.16 1160.84 1.00 General
AIRLOOP T N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 266.45 1160.84 1.00 General
AIRLOOP T N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 266.43 1160.84 1.00 General
AIRLOOP T S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 288.47 1160.84 1.00 General
AIRLOOP T S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 289.07 1160.84 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
SHWSYS1 PUMP Pump:ConstantSpeed Intermittent 29891.00 0.0003 36.93 127739.32 0.30
PLANT CIRC PUMP Pump:ConstantSpeed Intermittent 224180.02 0.0076 2416.67 319344.75 0.90


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
SHWSYS1 WATER HEATER WaterHeater:Mixed 2.27 175842.64 0.80 0.00 0.00



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:57

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 2677.56 3213.07 0.210 0.252 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 16:45:00 34.79 0.01519
G NW APARTMENT 2738.97 3286.76 0.215 0.258 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 34.08 0.01519
OFFICE 3652.23 4382.67 0.287 0.344 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 10:45:00 33.30 0.01519
G NE APARTMENT 2166.08 2599.30 0.170 0.204 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 32.54 0.01519
G N1 APARTMENT 1379.53 1655.43 0.108 0.130 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 32.82 0.01519
G N2 APARTMENT 1367.96 1641.56 0.107 0.129 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 32.82 0.01519
G S1 APARTMENT 1356.45 1627.74 0.107 0.128 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 35.87 0.01519
G S2 APARTMENT 1417.20 1700.64 0.111 0.134 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 35.87 0.01519
F2 SW APARTMENT 3147.64 3777.17 0.247 0.297 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 17:00:00 34.59 0.01519
F2 NW APARTMENT 3204.88 3845.85 0.252 0.302 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 34.08 0.01519
F2 SE APARTMENT 2857.01 3428.42 0.225 0.269 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 11:00:00 33.68 0.01519
F2 NE APARTMENT 2576.37 3091.64 0.202 0.243 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 32.54 0.01519
F2 N1 APARTMENT 1682.40 2018.88 0.132 0.159 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 33.20 0.01519
F2 N2 APARTMENT 1673.28 2007.94 0.131 0.158 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 33.20 0.01519
F2 S1 APARTMENT 1667.96 2001.55 0.131 0.157 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 35.87 0.01519
F2 S2 APARTMENT 1688.84 2026.60 0.133 0.159 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 35.87 0.01519
F3 SW APARTMENT 3159.27 3791.13 0.248 0.298 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 17:00:00 34.59 0.01519
F3 NW APARTMENT 3218.33 3862.00 0.253 0.303 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 34.08 0.01519
F3 SE APARTMENT 2663.10 3195.72 0.209 0.251 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 11:00:00 33.68 0.01519
F3 NE APARTMENT 2595.42 3114.50 0.204 0.245 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 32.54 0.01519
F3 N1 APARTMENT 1710.19 2052.23 0.134 0.161 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 33.20 0.01519
F3 N2 APARTMENT 1701.17 2041.40 0.134 0.160 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 33.20 0.01519
F3 S1 APARTMENT 1699.06 2038.87 0.134 0.160 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 35.87 0.01519
F3 S2 APARTMENT 1707.44 2048.93 0.134 0.161 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 35.87 0.01519
F4 SW APARTMENT 3172.03 3806.44 0.249 0.299 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 17:00:00 34.59 0.01519
F4 NW APARTMENT 3230.40 3876.48 0.254 0.305 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 34.08 0.01519
F4 SE APARTMENT 2651.14 3181.37 0.208 0.250 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 11:00:00 33.68 0.01519
F4 NE APARTMENT 2603.45 3124.14 0.205 0.246 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 32.92 0.01519
F4 N1 APARTMENT 1729.17 2075.00 0.136 0.163 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 33.20 0.01519
F4 N2 APARTMENT 1720.21 2064.26 0.135 0.162 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 33.20 0.01519
F4 S1 APARTMENT 1717.43 2060.91 0.135 0.162 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 35.87 0.01519
F4 S2 APARTMENT 1723.86 2068.63 0.135 0.163 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 35.87 0.01519
M SW APARTMENT 3203.82 3844.58 0.252 0.302 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 17:00:00 34.59 0.01519
M NW APARTMENT 3262.41 3914.89 0.256 0.308 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 34.08 0.01519
M SE APARTMENT 2677.59 3213.11 0.210 0.253 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 11:00:00 33.68 0.01519
M NE APARTMENT 2632.19 3158.63 0.207 0.248 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 32.92 0.01519
M N1 APARTMENT 1765.64 2118.77 0.139 0.166 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 33.20 0.01519
M N2 APARTMENT 1756.75 2108.10 0.138 0.166 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 33.20 0.01519
M S1 APARTMENT 1752.53 2103.04 0.138 0.165 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 35.87 0.01519
M S2 APARTMENT 1758.64 2110.37 0.138 0.166 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 35.87 0.01519
F6 SW APARTMENT 3177.59 3813.11 0.250 0.300 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 16:45:00 34.79 0.01519
F6 NW APARTMENT 3234.81 3881.77 0.254 0.305 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 34.08 0.01519
F6 SE APARTMENT 2649.45 3179.34 0.208 0.250 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 11:00:00 33.68 0.01519
F6 NE APARTMENT 2602.82 3123.39 0.205 0.245 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 32.92 0.01519
F6 N1 APARTMENT 1744.24 2093.09 0.137 0.164 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 33.20 0.01519
F6 N2 APARTMENT 1735.45 2082.55 0.136 0.164 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 33.20 0.01519
F6 S1 APARTMENT 1731.50 2077.79 0.136 0.163 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 35.87 0.01519
F6 S2 APARTMENT 1737.51 2085.01 0.137 0.164 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 35.87 0.01519
F7 SW APARTMENT 3172.33 3806.80 0.249 0.299 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 16:45:00 34.79 0.01519
F7 NW APARTMENT 3228.97 3874.77 0.254 0.304 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 34.08 0.01519
F7 SE APARTMENT 2642.19 3170.63 0.208 0.249 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 11:00:00 33.68 0.01519
F7 NE APARTMENT 2595.16 3114.19 0.204 0.245 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 32.92 0.01519
F7 N1 APARTMENT 1743.05 2091.66 0.137 0.164 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 33.20 0.01519
F7 N2 APARTMENT 1734.34 2081.21 0.136 0.164 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 33.20 0.01519
F7 S1 APARTMENT 1729.81 2075.77 0.136 0.163 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 35.87 0.01519
F7 S2 APARTMENT 1735.77 2082.92 0.136 0.164 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 35.87 0.01519
F8 SW APARTMENT 3181.57 3817.88 0.250 0.300 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 16:45:00 34.79 0.01519
F8 NW APARTMENT 3237.83 3885.40 0.254 0.305 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 34.08 0.01519
F8 SE APARTMENT 2649.24 3179.09 0.208 0.250 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 11:00:00 33.68 0.01519
F8 NE APARTMENT 2601.62 3121.94 0.204 0.245 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 32.92 0.01519
F8 N1 APARTMENT 1756.02 2107.23 0.138 0.166 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 33.20 0.01519
F8 N2 APARTMENT 1747.39 2096.87 0.137 0.165 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 33.20 0.01519
F8 S1 APARTMENT 1741.54 2089.85 0.137 0.164 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 35.87 0.01519
F8 S2 APARTMENT 1747.46 2096.96 0.137 0.165 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 35.87 0.01519
F9 SW APARTMENT 3287.68 3945.22 0.258 0.310 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 17:00:00 34.59 0.01519
F9 NW APARTMENT 3346.31 4015.57 0.263 0.316 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 34.08 0.01519
F9 SE APARTMENT 2703.37 3244.04 0.212 0.255 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 11:00:00 33.68 0.01519
F9 NE APARTMENT 2652.14 3182.56 0.208 0.250 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 32.92 0.01519
F9 N1 APARTMENT 1858.44 2230.12 0.146 0.175 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 33.20 0.01519
F9 N2 APARTMENT 1849.79 2219.75 0.145 0.174 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 33.20 0.01519
F9 S1 APARTMENT 1816.33 2179.60 0.143 0.171 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 36.00 0.01519
F9 S2 APARTMENT 1822.17 2186.60 0.143 0.172 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 36.00 0.01519
T SW APARTMENT 4051.32 4861.58 0.318 0.382 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 34.99 0.01519
T NW APARTMENT 4045.16 4854.19 0.318 0.381 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 16:45:00 34.79 0.01519
T SE APARTMENT 3382.49 4058.99 0.266 0.319 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 35.87 0.01519
T NE APARTMENT 3262.33 3914.79 0.256 0.308 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 11:00:00 33.68 0.01519
T N1 APARTMENT 2434.04 2920.85 0.191 0.230 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 14:45:00 36.00 0.01519
T N2 APARTMENT 2433.85 2920.62 0.191 0.230 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 14:45:00 36.00 0.01519
T S1 APARTMENT 2635.23 3162.27 0.207 0.249 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 36.00 0.01519
T S2 APARTMENT 2640.70 3168.84 0.208 0.249 HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 36.00 0.01519


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1691.44 2029.73 0.076 0.091 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -1.60 0.00331
G NW APARTMENT 1685.31 2022.37 0.075 0.090 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -1.60 0.00331
OFFICE 1971.87 2366.25 0.088 0.106 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 18:45:00 -1.60 0.00331
G NE APARTMENT 1685.31 2022.37 0.075 0.090 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -1.60 0.00331
G N1 APARTMENT 1048.61 1258.33 0.047 0.056 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -1.60 0.00331
G N2 APARTMENT 1048.61 1258.33 0.047 0.056 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -1.60 0.00331
G S1 APARTMENT 1052.89 1263.47 0.047 0.056 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -1.60 0.00331
G S2 APARTMENT 1058.26 1269.91 0.047 0.057 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -1.60 0.00331
F2 SW APARTMENT 1684.93 2021.91 0.075 0.090 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F2 NW APARTMENT 1678.94 2014.73 0.075 0.090 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F2 SE APARTMENT 1701.09 2041.31 0.076 0.091 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F2 NE APARTMENT 1678.94 2014.73 0.075 0.090 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F2 N1 APARTMENT 915.59 1098.71 0.041 0.049 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F2 N2 APARTMENT 915.59 1098.71 0.041 0.049 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F2 S1 APARTMENT 923.96 1108.75 0.041 0.050 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F2 S2 APARTMENT 925.08 1110.09 0.041 0.050 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F3 SW APARTMENT 1704.88 2045.85 0.076 0.091 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F3 NW APARTMENT 1701.77 2042.12 0.076 0.091 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F3 SE APARTMENT 1706.77 2048.12 0.076 0.091 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F3 NE APARTMENT 1701.77 2042.12 0.076 0.091 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F3 N1 APARTMENT 903.57 1084.29 0.040 0.048 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F3 N2 APARTMENT 903.57 1084.29 0.040 0.048 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F3 S1 APARTMENT 907.23 1088.67 0.041 0.049 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F3 S2 APARTMENT 907.41 1088.89 0.041 0.049 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F4 SW APARTMENT 1753.10 2103.72 0.078 0.094 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F4 NW APARTMENT 1752.53 2103.03 0.078 0.094 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F4 SE APARTMENT 1753.31 2103.97 0.078 0.094 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F4 NE APARTMENT 1752.53 2103.03 0.078 0.094 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F4 N1 APARTMENT 926.41 1111.69 0.041 0.050 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F4 N2 APARTMENT 926.41 1111.69 0.041 0.050 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F4 S1 APARTMENT 927.26 1112.71 0.041 0.050 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F4 S2 APARTMENT 927.28 1112.74 0.041 0.050 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
M SW APARTMENT 1782.98 2139.57 0.080 0.096 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
M NW APARTMENT 1783.60 2140.32 0.080 0.096 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
M SE APARTMENT 1783.00 2139.60 0.080 0.096 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
M NE APARTMENT 1783.60 2140.32 0.080 0.096 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
M N1 APARTMENT 935.89 1123.07 0.042 0.050 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
M N2 APARTMENT 935.89 1123.07 0.042 0.050 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
M S1 APARTMENT 935.47 1122.56 0.042 0.050 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
M S2 APARTMENT 935.47 1122.57 0.042 0.050 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F6 SW APARTMENT 1857.77 2229.32 0.083 0.100 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F6 NW APARTMENT 1860.79 2232.95 0.083 0.100 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F6 SE APARTMENT 1857.77 2229.32 0.083 0.100 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F6 NE APARTMENT 1860.79 2232.95 0.083 0.100 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F6 N1 APARTMENT 992.34 1190.80 0.044 0.053 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F6 N2 APARTMENT 992.34 1190.80 0.044 0.053 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F6 S1 APARTMENT 989.49 1187.38 0.044 0.053 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F6 S2 APARTMENT 989.49 1187.38 0.044 0.053 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F7 SW APARTMENT 1911.08 2293.30 0.085 0.102 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F7 NW APARTMENT 1915.45 2298.54 0.086 0.103 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F7 SE APARTMENT 1911.08 2293.30 0.085 0.102 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F7 NE APARTMENT 1915.45 2298.54 0.086 0.103 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F7 N1 APARTMENT 1029.92 1235.90 0.046 0.055 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F7 N2 APARTMENT 1029.92 1235.90 0.046 0.055 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F7 S1 APARTMENT 1025.71 1230.86 0.046 0.055 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F7 S2 APARTMENT 1025.72 1230.86 0.046 0.055 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F8 SW APARTMENT 1965.69 2358.83 0.088 0.105 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F8 NW APARTMENT 1971.10 2365.32 0.088 0.106 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F8 SE APARTMENT 1965.69 2358.83 0.088 0.105 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F8 NE APARTMENT 1971.10 2365.32 0.088 0.106 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F8 N1 APARTMENT 1070.36 1284.43 0.048 0.057 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F8 N2 APARTMENT 1070.36 1284.43 0.048 0.057 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F8 S1 APARTMENT 1065.10 1278.13 0.048 0.057 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F8 S2 APARTMENT 1065.10 1278.13 0.048 0.057 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F9 SW APARTMENT 2102.66 2523.19 0.094 0.113 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F9 NW APARTMENT 2107.45 2528.94 0.094 0.113 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F9 SE APARTMENT 2102.66 2523.19 0.094 0.113 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F9 NE APARTMENT 2107.45 2528.94 0.094 0.113 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F9 N1 APARTMENT 1186.81 1424.17 0.053 0.064 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F9 N2 APARTMENT 1186.81 1424.17 0.053 0.064 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F9 S1 APARTMENT 1181.98 1418.37 0.053 0.063 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
F9 S2 APARTMENT 1181.98 1418.37 0.053 0.063 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
T SW APARTMENT 2523.75 3028.50 0.113 0.135 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
T NW APARTMENT 2533.06 3039.67 0.113 0.136 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
T SE APARTMENT 2523.75 3028.50 0.113 0.135 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
T NE APARTMENT 2533.06 3039.67 0.113 0.136 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
T N1 APARTMENT 1638.29 1965.94 0.073 0.088 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
T N2 APARTMENT 1638.29 1965.94 0.073 0.088 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
T S1 APARTMENT 1628.22 1953.86 0.073 0.087 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331
T S2 APARTMENT 1628.22 1953.86 0.073 0.087 HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -1.60 0.00331


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
AIRLOOP G SW 0.25 0.25 0.09 0.09
AIRLOOP G NW 0.26 0.26 0.09 0.09
AIRLOOP OFFICE 0.34 0.34 0.11 0.11
AIRLOOP G NE 0.20 0.20 0.09 0.09
AIRLOOP G N1 0.13 0.13 0.06 0.06
AIRLOOP G N2 0.13 0.13 0.06 0.06
AIRLOOP G S1 0.13 0.13 0.06 0.06
AIRLOOP G S2 0.13 0.13 0.06 0.06
AIRLOOP F2 SW 0.30 0.30 0.09 0.09
AIRLOOP F2 NW 0.30 0.30 0.09 0.09
AIRLOOP F2 SE 0.27 0.27 0.09 0.09
AIRLOOP F2 NE 0.24 0.24 0.09 0.09
AIRLOOP F2 N1 0.16 0.16 0.05 0.05
AIRLOOP F2 N2 0.16 0.16 0.05 0.05
AIRLOOP F2 S1 0.16 0.16 0.05 0.05
AIRLOOP F2 S2 0.16 0.16 0.05 0.05
AIRLOOP F3 SW 0.30 0.30 0.09 0.09
AIRLOOP F3 NW 0.30 0.30 0.09 0.09
AIRLOOP F3 SE 0.25 0.25 0.09 0.09
AIRLOOP F3 NE 0.24 0.24 0.09 0.09
AIRLOOP F3 N1 0.16 0.16 0.05 0.05
AIRLOOP F3 N2 0.16 0.16 0.05 0.05
AIRLOOP F3 S1 0.16 0.16 0.05 0.05
AIRLOOP F3 S2 0.16 0.16 0.05 0.05
AIRLOOP F4 SW 0.30 0.30 0.09 0.09
AIRLOOP F4 NW 0.30 0.30 0.09 0.09
AIRLOOP F4 SE 0.25 0.25 0.09 0.09
AIRLOOP F4 NE 0.25 0.25 0.09 0.09
AIRLOOP F4 N1 0.16 0.16 0.05 0.05
AIRLOOP F4 N2 0.16 0.16 0.05 0.05
AIRLOOP F4 S1 0.16 0.16 0.05 0.05
AIRLOOP F4 S2 0.16 0.16 0.05 0.05
AIRLOOP M SW 0.30 0.30 0.10 0.10
AIRLOOP M NW 0.31 0.31 0.10 0.10
AIRLOOP M SE 0.25 0.25 0.10 0.10
AIRLOOP M NE 0.25 0.25 0.10 0.10
AIRLOOP M N1 0.17 0.17 0.05 0.05
AIRLOOP M N2 0.17 0.17 0.05 0.05
AIRLOOP M S1 0.17 0.17 0.05 0.05
AIRLOOP M S2 0.17 0.17 0.05 0.05
AIRLOOP F6 SW 0.30 0.30 0.10 0.10
AIRLOOP F6 NW 0.31 0.31 0.10 0.10
AIRLOOP F6 SE 0.25 0.25 0.10 0.10
AIRLOOP F6 NE 0.25 0.25 0.10 0.10
AIRLOOP F6 N1 0.16 0.16 0.05 0.05
AIRLOOP F6 N2 0.16 0.16 0.05 0.05
AIRLOOP F6 S1 0.16 0.16 0.05 0.05
AIRLOOP F6 S2 0.16 0.16 0.05 0.05
AIRLOOP F7 SW 0.30 0.30 0.10 0.10
AIRLOOP F7 NW 0.30 0.30 0.10 0.10
AIRLOOP F7 SE 0.25 0.25 0.10 0.10
AIRLOOP F7 NE 0.24 0.24 0.10 0.10
AIRLOOP F7 N1 0.16 0.16 0.06 0.06
AIRLOOP F7 N2 0.16 0.16 0.06 0.06
AIRLOOP F7 S1 0.16 0.16 0.05 0.05
AIRLOOP F7 S2 0.16 0.16 0.05 0.05
AIRLOOP F8 SW 0.30 0.30 0.11 0.11
AIRLOOP F8 NW 0.31 0.31 0.11 0.11
AIRLOOP F8 SE 0.25 0.25 0.11 0.11
AIRLOOP F8 NE 0.25 0.25 0.11 0.11
AIRLOOP F8 N1 0.17 0.17 0.06 0.06
AIRLOOP F8 N2 0.16 0.16 0.06 0.06
AIRLOOP F8 S1 0.16 0.16 0.06 0.06
AIRLOOP F8 S2 0.16 0.16 0.06 0.06
AIRLOOP F9 SW 0.31 0.31 0.11 0.11
AIRLOOP F9 NW 0.32 0.32 0.11 0.11
AIRLOOP F9 SE 0.25 0.25 0.11 0.11
AIRLOOP F9 NE 0.25 0.25 0.11 0.11
AIRLOOP F9 N1 0.18 0.18 0.06 0.06
AIRLOOP F9 N2 0.17 0.17 0.06 0.06
AIRLOOP F9 S1 0.17 0.17 0.06 0.06
AIRLOOP F9 S2 0.17 0.17 0.06 0.06
AIRLOOP T SW 0.38 0.38 0.14 0.14
AIRLOOP T NW 0.38 0.38 0.14 0.14
AIRLOOP T SE 0.32 0.32 0.14 0.14
AIRLOOP T NE 0.31 0.31 0.14 0.14
AIRLOOP T N1 0.23 0.23 0.09 0.09
AIRLOOP T N2 0.23 0.23 0.09 0.09
AIRLOOP T S1 0.25 0.25 0.09 0.09
AIRLOOP T S2 0.25 0.25 0.09 0.09



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:57

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 5474.75 5980.00 3083.25
G NW APARTMENT 5324.00 6400.75 3183.75
OFFICE 1617.75 320.50 15.25
G NE APARTMENT 5306.75 6321.00 3066.00
G N1 APARTMENT 5257.00 6583.25 3261.75
G N2 APARTMENT 5254.50 6576.75 3252.50
G S1 APARTMENT 5400.50 5993.25 3004.00
G S2 APARTMENT 5425.00 5934.25 2991.25
F2 SW APARTMENT 5910.25 4202.50 1923.25
F2 NW APARTMENT 5581.25 4945.50 2093.00
F2 SE APARTMENT 6014.00 3817.75 1683.50
F2 NE APARTMENT 5563.25 4948.50 2064.00
F2 N1 APARTMENT 5539.75 5070.75 2127.25
F2 N2 APARTMENT 5537.00 5078.00 2130.50
F2 S1 APARTMENT 5902.75 4076.75 1866.00
F2 S2 APARTMENT 5917.25 4039.50 1850.50
F3 SW APARTMENT 5993.75 4063.75 1893.25
F3 NW APARTMENT 5653.00 4786.50 2030.00
F3 SE APARTMENT 5990.50 3975.00 1795.75
F3 NE APARTMENT 5620.50 4781.25 1978.00
F3 N1 APARTMENT 5622.75 4800.50 1981.00
F3 N2 APARTMENT 5618.75 4804.25 1978.25
F3 S1 APARTMENT 6031.25 3756.25 1745.75
F3 S2 APARTMENT 6033.25 3754.50 1746.25
F4 SW APARTMENT 6018.50 4076.00 1931.00
F4 NW APARTMENT 5672.00 4792.50 2059.25
F4 SE APARTMENT 5985.00 4035.25 1846.50
F4 NE APARTMENT 5631.25 4778.75 2000.25
F4 N1 APARTMENT 5663.00 4740.50 1977.00
F4 N2 APARTMENT 5657.00 4743.75 1976.50
F4 S1 APARTMENT 6077.25 3702.00 1755.50
F4 S2 APARTMENT 6075.00 3709.75 1756.25
M SW APARTMENT 6007.00 4097.25 1933.00
M NW APARTMENT 5666.75 4781.75 2049.75
M SE APARTMENT 5969.75 4068.75 1851.50
M NE APARTMENT 5630.00 4762.50 1985.00
M N1 APARTMENT 5668.75 4701.75 1946.75
M N2 APARTMENT 5664.50 4705.50 1946.25
M S1 APARTMENT 6079.50 3696.50 1744.50
M S2 APARTMENT 6074.50 3705.75 1745.25
F6 SW APARTMENT 5932.25 4321.50 2053.75
F6 NW APARTMENT 5602.75 4993.75 2191.25
F6 SE APARTMENT 5884.00 4296.50 1970.25
F6 NE APARTMENT 5570.75 4977.25 2128.75
F6 N1 APARTMENT 5594.25 4880.50 2045.25
F6 N2 APARTMENT 5590.00 4886.50 2046.75
F6 S1 APARTMENT 5989.75 3943.75 1844.00
F6 S2 APARTMENT 5983.00 3955.75 1846.25
F7 SW APARTMENT 5877.25 4481.50 2136.00
F7 NW APARTMENT 5561.50 5134.25 2279.25
F7 SE APARTMENT 5825.00 4460.25 2057.75
F7 NE APARTMENT 5539.00 5120.50 2211.00
F7 N1 APARTMENT 5556.00 4987.50 2097.75
F7 N2 APARTMENT 5553.50 4991.50 2096.25
F7 S1 APARTMENT 5930.00 4104.00 1903.25
F7 S2 APARTMENT 5927.00 4111.50 1905.75
F8 SW APARTMENT 5830.75 4583.75 2179.75
F8 NW APARTMENT 5537.25 5219.25 2330.75
F8 SE APARTMENT 5773.25 4578.25 2113.25
F8 NE APARTMENT 5509.00 5207.25 2252.00
F8 N1 APARTMENT 5523.50 5058.75 2123.00
F8 N2 APARTMENT 5520.50 5060.50 2119.75
F8 S1 APARTMENT 5880.50 4204.50 1934.00
F8 S2 APARTMENT 5877.50 4218.50 1938.25
F9 SW APARTMENT 5783.25 4619.25 2158.50
F9 NW APARTMENT 5522.50 5203.25 2292.25
F9 SE APARTMENT 5733.50 4615.25 2081.75
F9 NE APARTMENT 5494.25 5208.75 2223.25
F9 N1 APARTMENT 5508.75 5069.50 2111.00
F9 N2 APARTMENT 5506.25 5073.75 2109.25
F9 S1 APARTMENT 5830.00 4294.00 1933.50
F9 S2 APARTMENT 5827.00 4299.00 1934.00
T SW APARTMENT 5870.50 5091.75 2603.75
T NW APARTMENT 5672.50 5540.00 2734.50
T SE APARTMENT 5857.75 5125.50 2591.75
T NE APARTMENT 5639.50 5565.50 2712.00
T N1 APARTMENT 5534.25 5454.25 2524.50
T N2 APARTMENT 5533.50 5459.25 2527.00
T S1 APARTMENT 5841.00 4858.75 2420.50
T S2 APARTMENT 5842.00 4867.75 2425.00
G CORRIDOR 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00
Facility 6563.75 6795.25 3681.50
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 0.25 8.25 0.25 8.25
G NW APARTMENT 0.00 3.00 0.00 3.00
OFFICE 0.75 5.25 0.00 3.25
G NE APARTMENT 0.00 8.50 0.00 8.50
G N1 APARTMENT 3.00 11.50 3.00 11.50
G N2 APARTMENT 3.00 11.50 3.00 11.50
G S1 APARTMENT 2.25 214.75 2.25 214.75
G S2 APARTMENT 1.00 179.25 1.00 179.25
F2 SW APARTMENT 0.00 6.50 0.00 6.50
F2 NW APARTMENT 0.00 2.00 0.00 2.00
F2 SE APARTMENT 0.25 11.50 0.25 11.50
F2 NE APARTMENT 0.00 2.00 0.00 2.00
F2 N1 APARTMENT 2.00 9.00 2.00 9.00
F2 N2 APARTMENT 1.75 9.25 1.75 9.25
F2 S1 APARTMENT 2.00 207.50 2.00 207.50
F2 S2 APARTMENT 1.50 190.25 1.50 190.25
F3 SW APARTMENT 0.25 6.50 0.25 6.50
F3 NW APARTMENT 0.00 2.25 0.00 2.25
F3 SE APARTMENT 0.25 44.50 0.25 44.50
F3 NE APARTMENT 0.00 4.00 0.00 4.00
F3 N1 APARTMENT 3.00 14.75 3.00 14.75
F3 N2 APARTMENT 2.75 15.50 2.75 15.50
F3 S1 APARTMENT 1.75 213.75 1.75 213.75
F3 S2 APARTMENT 2.25 209.00 2.25 209.00
F4 SW APARTMENT 0.50 6.50 0.50 6.50
F4 NW APARTMENT 0.00 2.00 0.00 2.00
F4 SE APARTMENT 0.50 50.00 0.50 50.00
F4 NE APARTMENT 0.00 3.75 0.00 3.75
F4 N1 APARTMENT 2.00 16.25 2.00 16.25
F4 N2 APARTMENT 1.00 16.50 1.00 16.50
F4 S1 APARTMENT 0.25 206.75 0.25 206.75
F4 S2 APARTMENT 1.50 203.25 1.50 203.25
M SW APARTMENT 0.00 6.50 0.00 6.50
M NW APARTMENT 0.00 2.50 0.00 2.50
M SE APARTMENT 0.00 47.00 0.00 47.00
M NE APARTMENT 0.00 4.25 0.00 4.25
M N1 APARTMENT 2.00 16.75 2.00 16.75
M N2 APARTMENT 1.00 17.75 1.00 17.75
M S1 APARTMENT 1.00 199.25 1.00 199.25
M S2 APARTMENT 1.25 197.50 1.25 197.50
F6 SW APARTMENT 0.00 6.50 0.00 6.50
F6 NW APARTMENT 0.00 3.00 0.00 3.00
F6 SE APARTMENT 0.00 47.50 0.00 47.50
F6 NE APARTMENT 0.00 4.25 0.00 4.25
F6 N1 APARTMENT 1.25 18.50 1.25 18.50
F6 N2 APARTMENT 1.50 19.50 1.50 19.50
F6 S1 APARTMENT 1.25 193.50 1.25 193.50
F6 S2 APARTMENT 1.00 189.75 1.00 189.75
F7 SW APARTMENT 0.00 6.50 0.00 6.50
F7 NW APARTMENT 0.00 3.25 0.00 3.25
F7 SE APARTMENT 0.00 46.25 0.00 46.25
F7 NE APARTMENT 0.00 4.75 0.00 4.75
F7 N1 APARTMENT 0.75 19.75 0.75 19.75
F7 N2 APARTMENT 0.25 21.00 0.25 21.00
F7 S1 APARTMENT 1.50 186.75 1.50 186.75
F7 S2 APARTMENT 2.00 182.25 2.00 182.25
F8 SW APARTMENT 0.50 6.75 0.50 6.75
F8 NW APARTMENT 0.00 3.50 0.00 3.50
F8 SE APARTMENT 0.50 44.00 0.50 44.00
F8 NE APARTMENT 0.00 6.25 0.00 6.25
F8 N1 APARTMENT 2.00 21.50 2.00 21.50
F8 N2 APARTMENT 2.00 22.00 2.00 22.00
F8 S1 APARTMENT 0.50 176.00 0.50 176.00
F8 S2 APARTMENT 0.75 173.25 0.75 173.25
F9 SW APARTMENT 0.00 6.25 0.00 6.25
F9 NW APARTMENT 0.00 3.75 0.00 3.75
F9 SE APARTMENT 0.25 39.00 0.25 39.00
F9 NE APARTMENT 0.00 7.50 0.00 7.50
F9 N1 APARTMENT 1.50 18.75 1.50 18.75
F9 N2 APARTMENT 1.50 20.25 1.50 20.25
F9 S1 APARTMENT 0.00 147.00 0.00 147.00
F9 S2 APARTMENT 1.25 143.00 1.25 143.00
T SW APARTMENT 0.00 7.50 0.00 7.50
T NW APARTMENT 0.00 3.75 0.00 3.75
T SE APARTMENT 0.00 19.25 0.00 19.25
T NE APARTMENT 0.00 2.75 0.00 2.75
T N1 APARTMENT 0.00 3.00 0.00 3.00
T N2 APARTMENT 0.00 3.00 0.00 3.00
T S1 APARTMENT 0.00 34.00 0.00 34.00
T S2 APARTMENT 0.25 34.75 0.25 34.75
G CORRIDOR 0.00 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
Facility 48.00 315.00 47.25 313.50
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:57

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.356 0.151 0.000 0.386
G NW APARTMENT 1.71 2.50 268.96 0.356 0.151 0.000 0.359
OFFICE 0.94 1.00 268.96 0.522 0.186 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.356 0.151 0.000 0.358
G N1 APARTMENT 1.71 2.50 268.96 0.356 0.091 0.000 0.351
G N2 APARTMENT 1.71 2.50 268.97 0.356 0.091 0.000 0.350
G S1 APARTMENT 1.71 2.50 268.96 0.356 0.091 0.000 0.382
G S2 APARTMENT 1.71 2.50 268.97 0.356 0.091 0.000 0.383
F2 SW APARTMENT 1.71 2.50 268.96 0.356 0.217 0.000 0.458
F2 NW APARTMENT 1.71 2.50 268.96 0.356 0.217 0.000 0.422
F2 SE APARTMENT 1.71 2.50 268.96 0.356 0.217 0.000 0.460
F2 NE APARTMENT 1.71 2.50 268.96 0.356 0.217 0.000 0.421
F2 N1 APARTMENT 1.71 2.50 268.96 0.356 0.131 0.000 0.417
F2 N2 APARTMENT 1.71 2.50 268.97 0.356 0.131 0.000 0.417
F2 S1 APARTMENT 1.71 2.50 268.96 0.356 0.131 0.000 0.456
F2 S2 APARTMENT 1.71 2.50 268.97 0.356 0.131 0.000 0.457
F3 SW APARTMENT 1.71 2.50 268.96 0.356 0.257 0.000 0.514
F3 NW APARTMENT 1.71 2.50 268.96 0.356 0.256 0.000 0.470
F3 SE APARTMENT 1.71 2.50 268.96 0.356 0.257 0.000 0.513
F3 NE APARTMENT 1.71 2.50 268.96 0.356 0.256 0.000 0.469
F3 N1 APARTMENT 1.71 2.50 268.96 0.356 0.155 0.000 0.466
F3 N2 APARTMENT 1.71 2.50 268.97 0.356 0.155 0.000 0.466
F3 S1 APARTMENT 1.71 2.50 268.96 0.356 0.155 0.000 0.512
F3 S2 APARTMENT 1.71 2.50 268.97 0.356 0.155 0.000 0.512
F4 SW APARTMENT 1.71 2.50 268.96 0.356 0.287 0.000 0.538
F4 NW APARTMENT 1.71 2.50 268.96 0.356 0.286 0.000 0.490
F4 SE APARTMENT 1.71 2.50 268.96 0.356 0.287 0.000 0.537
F4 NE APARTMENT 1.71 2.50 268.96 0.356 0.286 0.000 0.489
F4 N1 APARTMENT 1.71 2.50 268.96 0.356 0.173 0.000 0.486
F4 N2 APARTMENT 1.71 2.50 268.97 0.356 0.173 0.000 0.486
F4 S1 APARTMENT 1.71 2.50 268.96 0.356 0.173 0.000 0.537
F4 S2 APARTMENT 1.71 2.50 268.97 0.356 0.173 0.000 0.537
M SW APARTMENT 1.71 2.50 268.96 0.356 0.311 0.000 0.566
M NW APARTMENT 1.71 2.50 268.96 0.356 0.311 0.000 0.514
M SE APARTMENT 1.71 2.50 268.96 0.356 0.311 0.000 0.565
M NE APARTMENT 1.71 2.50 268.96 0.356 0.311 0.000 0.513
M N1 APARTMENT 1.71 2.50 268.96 0.356 0.188 0.000 0.511
M N2 APARTMENT 1.71 2.50 268.97 0.356 0.188 0.000 0.511
M S1 APARTMENT 1.71 2.50 268.96 0.356 0.188 0.000 0.565
M S2 APARTMENT 1.71 2.50 268.97 0.356 0.188 0.000 0.565
F6 SW APARTMENT 1.71 2.50 268.96 0.356 0.333 0.000 0.590
F6 NW APARTMENT 1.71 2.50 268.96 0.356 0.333 0.000 0.534
F6 SE APARTMENT 1.71 2.50 268.96 0.356 0.333 0.000 0.589
F6 NE APARTMENT 1.71 2.50 268.96 0.356 0.333 0.000 0.533
F6 N1 APARTMENT 1.71 2.50 268.96 0.356 0.201 0.000 0.531
F6 N2 APARTMENT 1.71 2.50 268.97 0.356 0.201 0.000 0.531
F6 S1 APARTMENT 1.71 2.50 268.96 0.356 0.201 0.000 0.589
F6 S2 APARTMENT 1.71 2.50 268.97 0.356 0.201 0.000 0.589
F7 SW APARTMENT 1.71 2.50 268.96 0.356 0.352 0.000 0.611
F7 NW APARTMENT 1.71 2.50 268.96 0.356 0.351 0.000 0.552
F7 SE APARTMENT 1.71 2.50 268.96 0.356 0.352 0.000 0.610
F7 NE APARTMENT 1.71 2.50 268.96 0.356 0.351 0.000 0.551
F7 N1 APARTMENT 1.71 2.50 268.96 0.356 0.212 0.000 0.549
F7 N2 APARTMENT 1.71 2.50 268.97 0.356 0.212 0.000 0.549
F7 S1 APARTMENT 1.71 2.50 268.96 0.356 0.212 0.000 0.610
F7 S2 APARTMENT 1.71 2.50 268.97 0.356 0.212 0.000 0.610
F8 SW APARTMENT 1.71 2.50 268.96 0.356 0.369 0.000 0.632
F8 NW APARTMENT 1.71 2.50 268.96 0.356 0.368 0.000 0.571
F8 SE APARTMENT 1.71 2.50 268.96 0.356 0.369 0.000 0.632
F8 NE APARTMENT 1.71 2.50 268.96 0.356 0.368 0.000 0.570
F8 N1 APARTMENT 1.71 2.50 268.96 0.356 0.222 0.000 0.568
F8 N2 APARTMENT 1.71 2.50 268.97 0.356 0.222 0.000 0.568
F8 S1 APARTMENT 1.71 2.50 268.96 0.356 0.222 0.000 0.631
F8 S2 APARTMENT 1.71 2.50 268.97 0.356 0.222 0.000 0.631
F9 SW APARTMENT 1.71 2.50 268.96 0.356 0.384 0.000 0.654
F9 NW APARTMENT 1.71 2.50 268.96 0.356 0.384 0.000 0.589
F9 SE APARTMENT 1.71 2.50 268.96 0.356 0.384 0.000 0.653
F9 NE APARTMENT 1.71 2.50 268.96 0.356 0.384 0.000 0.588
F9 N1 APARTMENT 1.71 2.50 268.96 0.356 0.232 0.000 0.586
F9 N2 APARTMENT 1.71 2.50 268.97 0.356 0.232 0.000 0.586
F9 S1 APARTMENT 1.71 2.50 268.96 0.356 0.232 0.000 0.652
F9 S2 APARTMENT 1.71 2.50 268.97 0.356 0.232 0.000 0.652
T SW APARTMENT 1.71 2.50 268.96 0.356 0.398 0.000 0.669
T NW APARTMENT 1.71 2.50 268.96 0.356 0.398 0.000 0.603
T SE APARTMENT 1.71 2.50 268.96 0.356 0.398 0.000 0.669
T NE APARTMENT 1.71 2.50 268.96 0.356 0.398 0.000 0.603
T N1 APARTMENT 1.71 2.50 268.96 0.356 0.240 0.000 0.601
T N2 APARTMENT 1.71 2.50 268.97 0.356 0.240 0.000 0.601
T S1 APARTMENT 1.71 2.50 268.96 0.356 0.240 0.000 0.668
T S2 APARTMENT 1.71 2.50 268.97 0.356 0.240 0.000 0.668
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
OFFICE 0.94 1.00 268.96 0.501 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F2 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F2 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F3 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F3 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F4 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F4 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F6 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F6 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F7 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F7 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F8 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F8 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F9 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F9 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:57

Surfaces by Class

Total Outdoors
Wall 420 140
Floor 90 9
Roof 90 9
Internal Mass 80 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 140 140
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 80
Conditioned Zones 80
Unconditioned Zones 10
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 4156
Defaulted Fields 814
Fields with Defaults 11184
Autosized Fields 1293
Autosizable Fields 1630
Autocalculated Fields 907
Autocalculatable Fields 1710



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2015-09-09 19:11:57

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 3386.78 57747.05 08-JAN-04:00 189408.37 04-AUG-17:15
Electricity:Building 1433.88 25760.85 01-JAN-03:15 70162.48 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity 296.56 6715.87 01-JAN-00:15 14401.37 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 242.55 5824.91 01-JAN-00:15 11484.27 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:OFFICE 39.38 663.42 01-JAN-00:15 2934.49 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 29.88 469.18 01-JAN-00:15 2345.88 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:G CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F2 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F2 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F3 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F3 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F4 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F4 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:M SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M CORRIDOR 32.88 1042.61 01-JAN-00:15 1042.61 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 32.88 1042.61 01-JAN-00:15 1042.61 01-JAN-00:15
Electricity:Zone:F6 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F6 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F7 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F7 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F8 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F8 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F9 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F9 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:T SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T CORRIDOR 179.47 1701.70 01-JAN-00:15 10868.20 01-JAN-07:15
InteriorLights:Electricity:Zone:T CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 54.01 890.97 01-JAN-00:15 2917.11 01-JAN-19:15
InteriorEquipment:Electricity 1137.32 19044.98 01-JAN-03:15 57142.09 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 1137.32 19044.98 01-JAN-03:15 57142.09 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 9.50 194.24 01-JAN-00:15 588.62 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T CORRIDOR 163.03 1180.40 01-JAN-00:15 10346.90 01-JAN-07:15
Fans:Electricity 659.86 20924.02 15-FEB-06:30 20924.02 01-JAN-00:15
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Electricity:HVAC 1670.09 21585.27 08-JAN-04:00 113217.69 04-AUG-17:00
ElectricityProduced:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityProduced:HVAC 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricityProduced 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 3386.78 57747.05 08-JAN-04:00 189408.37 04-AUG-17:15
ElectricityPurchased:Plant 3386.78 57747.05 08-JAN-04:00 189408.37 04-AUG-17:15
Cogeneration:ElectricityPurchased 3386.78 57747.05 08-JAN-04:00 189408.37 04-AUG-17:15
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 3386.78 57747.05 08-JAN-04:00 189408.37 04-AUG-17:15
ElectricityNet:Plant 3386.78 57747.05 08-JAN-04:00 189408.37 04-AUG-17:15
Cogeneration:ElectricityNet 3386.78 57747.05 08-JAN-04:00 189408.37 04-AUG-17:15
ExteriorLights:Electricity 162.86 0.00 01-JAN-07:30 10364.00 01-JAN-00:15
General:ExteriorLights:Electricity 162.86 0.00 01-JAN-07:30 10364.00 01-JAN-00:15
General:Fans:Electricity 659.86 20924.02 15-FEB-06:30 20924.02 01-JAN-00:15
Cooling:Electricity 924.90 0.00 01-JAN-00:15 90298.51 04-AUG-17:00
Heating:Electricity 49.16 0.00 01-JAN-12:15 55626.00 11-FEB-05:00
Electricity:Plant 119.94 36.93 01-JAN-17:45 6106.79 03-JUN-17:00
HeatRejection:Electricity 46.83 0.00 01-JAN-00:15 3653.19 03-JUN-17:00
Boiler Parasitic:Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Pumps:Electricity 73.12 36.93 01-JAN-17:45 2453.60 01-JAN-00:15
WIRED_LTG_ELECTRICITY 0.44 0.00 01-JAN-00:15 21.60 01-JAN-19:30
WIRED_INT_EQUIP 979.40 1018.50 01-JAN-00:15 10185.00 01-JAN-07:15


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 1059.39 2357.00 01-JAN-00:15 278005.55 11-FEB-06:45
Gas:Plant 1059.39 2357.00 01-JAN-00:15 278005.55 11-FEB-06:45
WaterSystems:Gas 918.44 2357.00 01-JAN-00:15 74846.98 28-JAN-08:00
Water Heater:WaterSystems:Gas 918.44 2357.00 01-JAN-00:15 74846.98 28-JAN-08:00
Heating:Gas 140.95 0.00 01-JAN-00:15 230535.48 11-FEB-05:00
Boiler:Heating:Gas 140.95 0.00 01-JAN-00:15 230535.48 11-FEB-05:00


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
PlantLoopCoolingDemand:Facility 4155.40 0.00 01-JAN-00:15 425267.42 04-AUG-17:45
PlantLoopCoolingDemand:HVAC 4155.40 0.00 01-JAN-00:15 425267.42 04-AUG-17:45
CoolingCoils:PlantLoopCoolingDemand 4155.40 0.00 01-JAN-00:15 425267.42 04-AUG-17:45


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 7171.27 0.00 01-JAN-02:15 0.00 02-AUG-17:15
Water:Plant 7171.27 0.00 01-JAN-02:15 0.00 02-AUG-17:15
WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
MainsWater:Facility 7171.27 0.00 01-JAN-02:15 0.00 02-AUG-17:15
MainsWater:Plant 7171.27 0.00 01-JAN-02:15 0.00 02-AUG-17:15
WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
sub cat:WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
sub cat:WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
HeatRejection:Water 2392.76 0.00 01-JAN-00:15 0.00 01-AUG-16:00
HeatRejection:MainsWater 2392.76 0.00 01-JAN-00:15 0.00 01-AUG-16:00


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 843.07 353.19 29-JUL-01:15 208871.39 11-FEB-07:00
PlantLoopHeatingDemand:Plant 711.15 353.19 29-JUL-01:15 49706.72 25-JAN-08:00
WaterSystems:PlantLoopHeatingDemand 711.15 353.19 29-JUL-01:15 49706.72 25-JAN-08:00
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 6135.92 5815.02 13-APR-03:00 582762.37 11-FEB-05:00
EnergyTransfer:Building 1859.12 3734.30 01-MAR-22:15 211090.82 01-AUG-15:30
EnergyTransfer:Zone:G SW APARTMENT 19.65 0.03 20-APR-23:30 3273.81 28-SEP-15:15
Heating:EnergyTransfer 162.09 0.00 30-JAN-24:00 180765.22 11-FEB-04:00
Heating:EnergyTransfer:Zone:G SW APARTMENT 2.36 0.00 01-JAN-08:15 1923.27 11-FEB-05:00
Cooling:EnergyTransfer 1697.03 0.00 04-JAN-00:30 211090.82 01-AUG-15:30
Cooling:EnergyTransfer:Zone:G SW APARTMENT 17.29 0.00 01-JAN-00:15 3273.81 28-SEP-15:15
EnergyTransfer:Zone:G NW APARTMENT 17.75 0.02 16-NOV-11:45 3054.30 01-AUG-17:30
Heating:EnergyTransfer:Zone:G NW APARTMENT 3.52 0.00 01-JAN-18:00 2020.25 11-FEB-05:00
Cooling:EnergyTransfer:Zone:G NW APARTMENT 14.23 0.00 01-JAN-00:15 3054.30 01-AUG-17:30
EnergyTransfer:Zone:OFFICE 28.85 0.02 25-OCT-23:30 4334.26 28-SEP-13:30
Heating:EnergyTransfer:Zone:OFFICE 1.50 0.00 01-JAN-07:45 1842.47 11-FEB-07:00
Cooling:EnergyTransfer:Zone:OFFICE 27.34 0.00 01-JAN-00:15 4334.26 28-SEP-13:30
EnergyTransfer:Zone:G NE APARTMENT 17.39 0.01 20-MAY-23:15 2194.25 03-AUG-10:00
Heating:EnergyTransfer:Zone:G NE APARTMENT 3.20 0.00 01-JAN-08:30 2037.41 11-FEB-05:00
Cooling:EnergyTransfer:Zone:G NE APARTMENT 14.19 0.00 01-JAN-00:15 2194.25 03-AUG-10:00
EnergyTransfer:Zone:G N1 APARTMENT 11.87 0.01 06-APR-08:30 1536.24 01-AUG-17:15
Heating:EnergyTransfer:Zone:G N1 APARTMENT 1.58 0.00 01-JAN-10:15 1254.73 23-JAN-14:00
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 10.28 0.00 01-JAN-00:15 1536.24 01-AUG-17:15
EnergyTransfer:Zone:G N2 APARTMENT 11.88 0.00 17-APR-00:45 1524.55 01-AUG-17:15
Heating:EnergyTransfer:Zone:G N2 APARTMENT 1.59 0.00 01-JAN-10:15 1250.80 23-JAN-14:00
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 10.29 0.00 01-JAN-00:15 1524.55 01-AUG-17:15
EnergyTransfer:Zone:G S1 APARTMENT 14.25 0.01 17-APR-03:30 1954.22 28-OCT-13:30
Heating:EnergyTransfer:Zone:G S1 APARTMENT 0.64 0.00 01-JAN-00:15 970.25 11-FEB-05:00
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 13.61 0.00 01-JAN-02:45 1954.22 28-OCT-13:30
EnergyTransfer:Zone:G S2 APARTMENT 14.58 0.00 06-DEC-23:00 2014.80 28-OCT-13:30
Heating:EnergyTransfer:Zone:G S2 APARTMENT 0.60 0.00 01-JAN-00:15 958.08 11-FEB-05:00
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 13.98 0.00 01-JAN-03:00 2014.80 28-OCT-13:30
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F2 SW APARTMENT 26.71 0.02 26-JAN-00:15 3818.44 28-SEP-14:45
Heating:EnergyTransfer:Zone:F2 SW APARTMENT 1.62 0.00 01-JAN-00:15 2093.67 11-FEB-05:00
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT 25.09 0.00 01-JAN-04:15 3818.44 28-SEP-14:45
EnergyTransfer:Zone:F2 NW APARTMENT 23.55 0.01 09-FEB-07:45 3497.55 01-AUG-16:15
Heating:EnergyTransfer:Zone:F2 NW APARTMENT 2.87 0.00 01-JAN-10:00 2326.03 11-FEB-04:15
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT 20.68 0.00 01-JAN-00:15 3497.55 01-AUG-16:15
EnergyTransfer:Zone:F2 SE APARTMENT 28.22 0.00 22-FEB-03:45 3452.24 28-SEP-13:45
Heating:EnergyTransfer:Zone:F2 SE APARTMENT 1.25 0.00 01-JAN-00:15 2012.98 11-FEB-05:00
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT 26.97 0.00 01-JAN-04:30 3452.24 28-SEP-13:45
EnergyTransfer:Zone:F2 NE APARTMENT 23.30 0.01 23-JAN-11:30 2630.82 03-AUG-10:00
Heating:EnergyTransfer:Zone:F2 NE APARTMENT 2.58 0.00 01-JAN-08:00 2351.84 11-FEB-04:00
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT 20.73 0.00 01-JAN-00:15 2630.82 03-AUG-10:00
EnergyTransfer:Zone:F2 N1 APARTMENT 16.92 0.00 20-JAN-19:15 1844.35 01-AUG-17:45
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT 0.94 0.00 01-JAN-07:30 1423.61 23-JAN-14:00
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT 15.98 0.00 01-JAN-00:15 1844.35 01-AUG-17:45
EnergyTransfer:Zone:F2 N2 APARTMENT 16.93 0.04 20-DEC-17:30 1834.78 01-AUG-17:45
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT 0.94 0.00 01-JAN-07:30 1418.81 23-JAN-14:00
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT 15.99 0.00 01-JAN-00:15 1834.78 01-AUG-17:45
EnergyTransfer:Zone:F2 S1 APARTMENT 20.89 0.00 09-APR-04:30 2388.14 28-OCT-13:30
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT 0.30 0.00 01-JAN-00:15 888.70 11-FEB-05:00
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT 20.59 0.00 03-JAN-08:00 2388.14 28-OCT-13:30
EnergyTransfer:Zone:F2 S2 APARTMENT 21.04 0.09 25-FEB-19:30 2410.23 28-OCT-13:30
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT 0.29 0.00 01-JAN-00:15 878.30 11-FEB-05:00
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT 20.75 0.00 03-JAN-08:00 2410.23 28-OCT-13:30
EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F3 SW APARTMENT 27.84 0.03 17-JAN-11:00 3820.56 28-SEP-14:45
Heating:EnergyTransfer:Zone:F3 SW APARTMENT 1.59 0.00 01-JAN-00:15 2322.04 11-FEB-05:00
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT 26.25 0.00 01-JAN-12:45 3820.56 28-SEP-14:45
EnergyTransfer:Zone:F3 NW APARTMENT 24.70 0.01 15-NOV-01:45 3549.37 01-AUG-16:15
Heating:EnergyTransfer:Zone:F3 NW APARTMENT 2.85 0.00 01-JAN-09:45 2586.56 11-FEB-04:00
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT 21.85 0.00 01-JAN-00:15 3549.37 01-AUG-16:15
EnergyTransfer:Zone:F3 SE APARTMENT 27.95 0.03 03-JAN-13:15 3301.79 29-OCT-13:45
Heating:EnergyTransfer:Zone:F3 SE APARTMENT 1.38 0.00 01-JAN-00:15 2319.35 11-FEB-05:00
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT 26.57 0.00 01-JAN-12:45 3301.79 29-OCT-13:45
EnergyTransfer:Zone:F3 NE APARTMENT 24.47 0.00 28-FEB-04:15 2656.38 01-JUL-10:00
Heating:EnergyTransfer:Zone:F3 NE APARTMENT 2.58 0.00 01-JAN-07:45 2614.63 11-FEB-04:00
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT 21.90 0.00 01-JAN-00:15 2656.38 01-JUL-10:00
EnergyTransfer:Zone:F3 N1 APARTMENT 18.18 0.00 29-JAN-03:00 1887.15 01-AUG-17:45
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT 0.87 0.00 01-JAN-00:15 1580.91 23-JAN-14:00
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT 17.31 0.00 01-JAN-00:45 1887.15 01-AUG-17:45
EnergyTransfer:Zone:F3 N2 APARTMENT 18.18 0.06 29-JAN-02:45 1877.64 01-AUG-17:45
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT 0.88 0.00 01-JAN-00:15 1575.79 23-JAN-14:00
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT 17.31 0.00 01-JAN-01:00 1877.64 01-AUG-17:45
EnergyTransfer:Zone:F3 S1 APARTMENT 22.32 0.03 26-FEB-08:00 2476.44 13-NOV-13:30
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT 0.27 0.00 01-JAN-00:15 974.19 11-FEB-05:00
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT 22.05 0.00 03-JAN-08:00 2476.44 13-NOV-13:30
EnergyTransfer:Zone:F3 S2 APARTMENT 22.35 0.01 10-APR-19:45 2482.26 13-NOV-13:00
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT 0.27 0.00 01-JAN-00:15 974.10 11-FEB-05:00
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT 22.09 0.00 03-JAN-08:00 2482.26 13-NOV-13:00
EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F4 SW APARTMENT 28.08 0.00 01-DEC-01:15 3816.26 31-OCT-15:15
Heating:EnergyTransfer:Zone:F4 SW APARTMENT 1.72 0.00 01-JAN-00:15 2552.59 11-FEB-05:00
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT 26.36 0.00 01-JAN-12:45 3816.26 31-OCT-15:15
EnergyTransfer:Zone:F4 NW APARTMENT 25.09 0.02 11-DEC-11:15 3588.66 01-AUG-16:15
Heating:EnergyTransfer:Zone:F4 NW APARTMENT 3.00 0.00 01-JAN-09:45 2827.57 11-FEB-04:00
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT 22.09 0.00 01-JAN-00:15 3588.66 01-AUG-16:15
EnergyTransfer:Zone:F4 SE APARTMENT 28.01 0.01 16-FEB-01:45 3306.73 29-OCT-13:45
Heating:EnergyTransfer:Zone:F4 SE APARTMENT 1.54 0.00 01-JAN-00:15 2568.35 11-FEB-04:45
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT 26.47 0.00 01-JAN-12:45 3306.73 29-OCT-13:45
EnergyTransfer:Zone:F4 NE APARTMENT 24.85 0.00 16-OCT-01:30 2850.89 11-FEB-04:00
Heating:EnergyTransfer:Zone:F4 NE APARTMENT 2.71 0.00 01-JAN-07:45 2850.89 11-FEB-04:00
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT 22.14 0.00 01-JAN-00:15 2707.86 04-AUG-14:00
EnergyTransfer:Zone:F4 N1 APARTMENT 18.53 0.01 03-OCT-19:30 1917.18 01-AUG-17:45
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT 0.90 0.00 01-JAN-00:15 1684.87 23-JAN-14:15
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT 17.64 0.00 01-JAN-01:15 1917.18 01-AUG-17:45
EnergyTransfer:Zone:F4 N2 APARTMENT 18.54 0.02 20-FEB-09:00 1907.72 01-AUG-17:45
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT 0.90 0.00 01-JAN-00:15 1680.43 23-JAN-14:15
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT 17.64 0.00 01-JAN-01:30 1907.72 01-AUG-17:45
EnergyTransfer:Zone:F4 S1 APARTMENT 22.59 0.02 19-MAY-07:45 2510.75 13-NOV-13:30
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT 0.29 0.00 01-JAN-00:15 1105.99 11-FEB-05:00
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT 22.30 0.00 04-JAN-00:30 2510.75 13-NOV-13:30
EnergyTransfer:Zone:F4 S2 APARTMENT 22.61 0.01 19-MAY-07:45 2513.63 13-NOV-13:30
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT 0.30 0.00 01-JAN-00:15 1110.02 11-FEB-05:00
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT 22.31 0.00 04-JAN-00:30 2513.63 13-NOV-13:30
EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M SW APARTMENT 28.51 0.02 14-JAN-09:00 3832.00 28-SEP-14:45
Heating:EnergyTransfer:Zone:M SW APARTMENT 1.87 0.00 01-JAN-00:15 2741.77 11-FEB-04:15
Cooling:EnergyTransfer:Zone:M SW APARTMENT 26.64 0.00 01-JAN-12:45 3832.00 28-SEP-14:45
EnergyTransfer:Zone:M NW APARTMENT 25.68 0.01 27-MAR-18:45 3642.29 01-AUG-16:15
Heating:EnergyTransfer:Zone:M NW APARTMENT 3.17 0.00 01-JAN-09:45 3020.01 11-FEB-04:00
Cooling:EnergyTransfer:Zone:M NW APARTMENT 22.51 0.00 01-JAN-00:15 3642.29 01-AUG-16:15
EnergyTransfer:Zone:M SE APARTMENT 28.40 0.09 03-JAN-04:15 3343.61 29-OCT-13:30
Heating:EnergyTransfer:Zone:M SE APARTMENT 1.68 0.00 01-JAN-00:15 2761.93 11-FEB-04:00
Cooling:EnergyTransfer:Zone:M SE APARTMENT 26.72 0.00 01-JAN-12:45 3343.61 29-OCT-13:30
EnergyTransfer:Zone:M NE APARTMENT 25.42 0.01 17-JAN-03:30 3038.98 11-FEB-04:00
Heating:EnergyTransfer:Zone:M NE APARTMENT 2.87 0.00 01-JAN-07:45 3038.98 11-FEB-04:00
Cooling:EnergyTransfer:Zone:M NE APARTMENT 22.55 0.00 01-JAN-00:15 2751.62 04-AUG-14:00
EnergyTransfer:Zone:M N1 APARTMENT 19.05 0.01 26-FEB-07:30 1964.03 01-AUG-17:45
Heating:EnergyTransfer:Zone:M N1 APARTMENT 0.96 0.00 01-JAN-00:15 1805.50 23-JAN-14:15
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 18.09 0.00 01-JAN-02:15 1964.03 01-AUG-17:45
EnergyTransfer:Zone:M N2 APARTMENT 19.05 0.00 22-NOV-19:00 1954.61 01-AUG-17:45
Heating:EnergyTransfer:Zone:M N2 APARTMENT 0.96 0.00 01-JAN-00:15 1801.70 23-JAN-14:15
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 18.09 0.00 01-JAN-02:15 1954.61 01-AUG-17:45
EnergyTransfer:Zone:M S1 APARTMENT 22.98 0.08 23-NOV-08:45 2530.18 28-OCT-13:30
Heating:EnergyTransfer:Zone:M S1 APARTMENT 0.34 0.00 01-JAN-00:15 1213.11 11-FEB-05:00
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 22.64 0.00 01-JAN-13:30 2530.18 28-OCT-13:30
EnergyTransfer:Zone:M S2 APARTMENT 22.98 0.00 16-JAN-15:00 2536.35 28-OCT-13:30
Heating:EnergyTransfer:Zone:M S2 APARTMENT 0.34 0.00 01-JAN-00:15 1218.09 11-FEB-05:00
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 22.64 0.00 01-JAN-13:30 2536.35 28-OCT-13:30
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F6 SW APARTMENT 27.96 0.03 12-DEC-20:15 3789.91 28-SEP-14:45
Heating:EnergyTransfer:Zone:F6 SW APARTMENT 2.15 0.00 01-JAN-00:15 2962.19 11-FEB-04:00
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT 25.82 0.00 01-JAN-12:45 3789.91 28-SEP-14:45
EnergyTransfer:Zone:F6 NW APARTMENT 25.44 0.03 03-DEC-21:45 3632.67 01-AUG-16:15
Heating:EnergyTransfer:Zone:F6 NW APARTMENT 3.55 0.00 01-JAN-09:45 3232.77 11-FEB-04:00
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT 21.89 0.00 01-JAN-00:15 3632.67 01-AUG-16:15
EnergyTransfer:Zone:F6 SE APARTMENT 27.84 0.03 03-MAR-13:30 3319.30 29-OCT-13:30
Heating:EnergyTransfer:Zone:F6 SE APARTMENT 1.95 0.00 01-JAN-00:15 2979.35 11-FEB-04:00
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT 25.89 0.00 01-JAN-06:00 3319.30 29-OCT-13:30
EnergyTransfer:Zone:F6 NE APARTMENT 25.17 0.02 26-DEC-11:30 3245.35 11-FEB-04:00
Heating:EnergyTransfer:Zone:F6 NE APARTMENT 3.25 0.00 01-JAN-07:45 3245.35 11-FEB-04:00
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT 21.92 0.00 01-JAN-00:15 2740.03 02-AUG-16:15
EnergyTransfer:Zone:F6 N1 APARTMENT 18.61 0.05 28-JAN-24:00 1972.62 23-JAN-14:15
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT 1.16 0.00 01-JAN-00:15 1972.62 23-JAN-14:15
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT 17.45 0.00 01-JAN-01:15 1947.36 01-AUG-17:45
EnergyTransfer:Zone:F6 N2 APARTMENT 18.62 0.00 27-JAN-02:30 1969.19 23-JAN-14:15
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT 1.17 0.00 01-JAN-00:15 1969.19 23-JAN-14:15
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT 17.45 0.00 01-JAN-01:15 1938.03 01-AUG-17:45
EnergyTransfer:Zone:F6 S1 APARTMENT 22.23 0.04 09-MAR-10:45 2510.22 28-OCT-13:30
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT 0.43 0.00 01-JAN-00:15 1362.98 11-FEB-05:00
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT 21.80 0.00 01-JAN-13:30 2510.22 28-OCT-13:30
EnergyTransfer:Zone:F6 S2 APARTMENT 22.23 0.00 01-JAN-15:00 2516.29 28-OCT-13:30
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT 0.44 0.00 01-JAN-00:15 1367.84 11-FEB-05:00
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT 21.80 0.00 01-JAN-13:30 2516.29 28-OCT-13:30
EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F7 SW APARTMENT 27.79 0.00 13-JAN-14:30 3769.99 28-SEP-14:45
Heating:EnergyTransfer:Zone:F7 SW APARTMENT 2.39 0.00 01-JAN-00:15 3145.12 11-FEB-04:00
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT 25.40 0.00 01-JAN-05:45 3769.99 28-SEP-14:45
EnergyTransfer:Zone:F7 NW APARTMENT 25.50 0.01 04-MAR-21:15 3642.39 01-AUG-16:15
Heating:EnergyTransfer:Zone:F7 NW APARTMENT 3.87 0.00 01-JAN-10:00 3407.82 11-FEB-04:00
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT 21.63 0.00 01-JAN-00:15 3642.39 01-AUG-16:15
EnergyTransfer:Zone:F7 SE APARTMENT 27.65 0.01 03-APR-01:45 3309.50 29-OCT-13:15
Heating:EnergyTransfer:Zone:F7 SE APARTMENT 2.18 0.00 01-JAN-00:15 3158.53 11-FEB-04:00
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT 25.47 0.00 01-JAN-04:45 3309.50 29-OCT-13:15
EnergyTransfer:Zone:F7 NE APARTMENT 25.21 0.07 14-APR-14:15 3415.81 11-FEB-04:00
Heating:EnergyTransfer:Zone:F7 NE APARTMENT 3.56 0.00 01-JAN-07:45 3415.81 11-FEB-04:00
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT 21.65 0.00 01-JAN-00:15 2756.43 02-AUG-16:15
EnergyTransfer:Zone:F7 N1 APARTMENT 18.51 0.08 25-NOV-02:30 2094.58 23-JAN-14:15
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT 1.33 0.00 01-JAN-00:15 2094.58 23-JAN-14:15
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT 17.18 0.00 01-JAN-01:15 1951.50 01-AUG-17:45
EnergyTransfer:Zone:F7 N2 APARTMENT 18.52 0.02 13-DEC-03:45 2091.72 23-JAN-14:15
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT 1.34 0.00 01-JAN-00:15 2091.72 23-JAN-14:15
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT 17.18 0.00 01-JAN-00:45 1942.24 01-AUG-17:45
EnergyTransfer:Zone:F7 S1 APARTMENT 21.89 0.05 03-DEC-15:00 2511.93 28-OCT-13:30
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT 0.53 0.00 01-JAN-00:15 1481.91 11-FEB-05:00
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT 21.37 0.00 01-JAN-12:45 2511.93 28-OCT-13:30
EnergyTransfer:Zone:F7 S2 APARTMENT 21.90 0.02 06-APR-08:00 2517.95 28-OCT-13:30
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT 0.53 0.00 01-JAN-00:15 1494.90 16-MAR-13:15
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT 21.37 0.00 01-JAN-12:45 2517.95 28-OCT-13:30
EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F8 SW APARTMENT 27.83 0.00 18-OCT-00:15 3761.23 28-SEP-14:45
Heating:EnergyTransfer:Zone:F8 SW APARTMENT 2.62 0.00 01-JAN-00:15 3298.20 11-FEB-04:00
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT 25.21 0.00 01-JAN-04:45 3761.23 28-SEP-14:45
EnergyTransfer:Zone:F8 NW APARTMENT 25.75 0.08 28-JAN-00:45 3663.15 01-AUG-16:15
Heating:EnergyTransfer:Zone:F8 NW APARTMENT 4.17 0.00 01-JAN-10:00 3555.25 11-FEB-04:00
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT 21.58 0.00 01-JAN-00:15 3663.15 01-AUG-16:15
EnergyTransfer:Zone:F8 SE APARTMENT 27.68 0.03 18-FEB-06:00 3308.83 11-FEB-04:00
Heating:EnergyTransfer:Zone:F8 SE APARTMENT 2.41 0.00 01-JAN-00:15 3308.83 11-FEB-04:00
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT 25.27 0.00 01-JAN-04:00 3304.30 29-OCT-12:45
EnergyTransfer:Zone:F8 NE APARTMENT 25.44 0.01 07-JAN-02:45 3560.24 11-FEB-04:00
Heating:EnergyTransfer:Zone:F8 NE APARTMENT 3.86 0.00 01-JAN-07:45 3560.24 11-FEB-04:00
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT 21.59 0.00 01-JAN-00:15 2783.46 02-AUG-16:15
EnergyTransfer:Zone:F8 N1 APARTMENT 18.63 0.13 10-APR-20:45 2209.67 23-JAN-14:15
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT 1.51 0.00 01-JAN-00:15 2209.67 23-JAN-14:15
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT 17.12 0.00 01-JAN-00:30 1969.89 01-AUG-17:45
EnergyTransfer:Zone:F8 N2 APARTMENT 18.63 0.01 23-MAR-23:30 2206.50 23-JAN-14:15
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT 1.51 0.00 01-JAN-00:15 2206.50 23-JAN-14:15
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT 17.12 0.00 01-JAN-00:30 1960.68 01-AUG-17:45
EnergyTransfer:Zone:F8 S1 APARTMENT 21.78 0.07 17-NOV-21:30 2527.83 28-OCT-13:30
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT 0.62 0.00 01-JAN-00:15 1674.39 16-MAR-13:15
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT 21.16 0.00 01-JAN-12:45 2527.83 28-OCT-13:30
EnergyTransfer:Zone:F8 S2 APARTMENT 21.79 0.00 22-NOV-19:00 2533.81 28-OCT-13:30
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT 0.63 0.00 01-JAN-00:15 1689.03 16-MAR-13:15
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT 21.16 0.00 01-JAN-12:45 2533.81 28-OCT-13:30
EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F9 SW APARTMENT 28.60 0.03 13-MAR-01:45 3865.03 01-AUG-15:30
Heating:EnergyTransfer:Zone:F9 SW APARTMENT 3.02 0.00 01-JAN-00:15 3468.73 11-FEB-04:00
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT 25.59 0.00 01-JAN-03:30 3865.03 01-AUG-15:30
EnergyTransfer:Zone:F9 NW APARTMENT 26.77 0.00 15-NOV-02:15 3769.66 01-AUG-16:15
Heating:EnergyTransfer:Zone:F9 NW APARTMENT 4.67 0.00 04-JAN-16:30 3711.77 11-FEB-04:00
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT 22.11 0.00 01-JAN-00:15 3769.66 01-AUG-16:15
EnergyTransfer:Zone:F9 SE APARTMENT 28.40 0.01 11-APR-22:45 3477.34 11-FEB-04:00
Heating:EnergyTransfer:Zone:F9 SE APARTMENT 2.76 0.00 01-JAN-00:15 3477.34 11-FEB-04:00
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT 25.64 0.00 01-JAN-03:00 3353.20 28-SEP-13:30
EnergyTransfer:Zone:F9 NE APARTMENT 26.40 0.07 17-OCT-17:15 3713.04 11-FEB-04:00
Heating:EnergyTransfer:Zone:F9 NE APARTMENT 4.30 0.00 01-JAN-08:00 3713.04 11-FEB-04:00
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT 22.10 0.00 01-JAN-00:15 2899.34 02-AUG-16:15
EnergyTransfer:Zone:F9 N1 APARTMENT 19.39 0.07 01-APR-03:30 2344.77 23-JAN-14:15
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT 1.82 0.00 01-JAN-07:30 2344.77 23-JAN-14:15
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT 17.56 0.00 01-JAN-00:15 2082.77 01-AUG-17:45
EnergyTransfer:Zone:F9 N2 APARTMENT 19.39 0.04 17-MAR-05:15 2340.56 23-JAN-14:15
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT 1.83 0.00 01-JAN-07:30 2340.56 23-JAN-14:15
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT 17.56 0.00 01-JAN-00:15 2073.51 01-AUG-17:45
EnergyTransfer:Zone:F9 S1 APARTMENT 22.25 0.11 03-OCT-20:00 2612.19 28-OCT-13:30
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT 0.80 0.00 01-JAN-00:15 1905.14 16-MAR-13:15
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT 21.45 0.00 01-JAN-12:45 2612.19 28-OCT-13:30
EnergyTransfer:Zone:F9 S2 APARTMENT 22.26 0.02 05-SEP-06:00 2618.04 28-OCT-13:30
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT 0.81 0.00 01-JAN-00:15 1918.71 16-MAR-13:15
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT 21.45 0.00 01-JAN-12:45 2618.04 28-OCT-13:30
EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:T SW APARTMENT 33.21 0.01 23-NOV-19:15 4759.39 01-AUG-15:15
Heating:EnergyTransfer:Zone:T SW APARTMENT 5.48 0.00 01-JAN-08:45 4418.48 11-FEB-04:00
Cooling:EnergyTransfer:Zone:T SW APARTMENT 27.74 0.00 01-JAN-00:15 4759.39 01-AUG-15:15
EnergyTransfer:Zone:T NW APARTMENT 31.28 0.08 28-FEB-10:15 4604.74 01-AUG-16:15
Heating:EnergyTransfer:Zone:T NW APARTMENT 7.04 0.00 27-JAN-15:30 4591.66 11-FEB-04:00
Cooling:EnergyTransfer:Zone:T NW APARTMENT 24.24 0.00 01-JAN-00:15 4604.74 01-AUG-16:15
EnergyTransfer:Zone:T SE APARTMENT 32.59 0.02 01-FEB-09:00 4405.91 11-FEB-04:00
Heating:EnergyTransfer:Zone:T SE APARTMENT 5.04 0.00 01-JAN-08:00 4405.91 11-FEB-04:00
Cooling:EnergyTransfer:Zone:T SE APARTMENT 27.55 0.00 01-JAN-00:15 4082.63 28-SEP-13:30
EnergyTransfer:Zone:T NE APARTMENT 30.46 0.04 26-DEC-18:45 4581.75 11-FEB-04:00
Heating:EnergyTransfer:Zone:T NE APARTMENT 6.46 0.00 01-JAN-09:15 4581.75 11-FEB-04:00
Cooling:EnergyTransfer:Zone:T NE APARTMENT 24.00 0.00 01-JAN-00:15 3594.84 02-AUG-16:15
EnergyTransfer:Zone:T N1 APARTMENT 22.51 0.00 16-FEB-01:45 2755.26 02-AUG-15:15
Heating:EnergyTransfer:Zone:T N1 APARTMENT 3.27 0.00 01-JAN-10:00 2737.05 11-FEB-04:00
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 19.24 0.00 01-JAN-00:15 2755.26 02-AUG-15:15
EnergyTransfer:Zone:T N2 APARTMENT 22.53 0.05 09-SEP-05:00 2751.96 02-AUG-15:30
Heating:EnergyTransfer:Zone:T N2 APARTMENT 3.28 0.00 01-JAN-09:45 2739.75 11-FEB-04:00
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 19.24 0.00 01-JAN-00:15 2751.96 02-AUG-15:30
EnergyTransfer:Zone:T S1 APARTMENT 25.16 0.04 29-OCT-03:30 3417.56 28-OCT-13:30
Heating:EnergyTransfer:Zone:T S1 APARTMENT 2.17 0.00 01-JAN-00:15 2556.51 11-FEB-04:00
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 22.98 0.00 01-JAN-00:30 3417.56 28-OCT-13:30
EnergyTransfer:Zone:T S2 APARTMENT 25.17 0.00 16-OCT-01:45 3416.46 28-OCT-13:30
Heating:EnergyTransfer:Zone:T S2 APARTMENT 2.19 0.00 01-JAN-00:15 2558.66 11-FEB-04:00
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 22.99 0.00 01-JAN-00:30 3416.46 28-OCT-13:30
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Plant 815.95 353.19 29-JUL-01:15 204219.05 11-FEB-07:00
WaterSystems:EnergyTransfer 711.15 353.19 29-JUL-01:15 49701.63 25-JAN-08:00
sub cat:WaterSystems:EnergyTransfer 711.15 353.19 29-JUL-01:15 49701.63 25-JAN-08:00
EnergyTransfer:HVAC 3460.85 0.00 01-JAN-17:45 338241.33 07-JUL-09:45
CoolingCoils:EnergyTransfer 3288.21 0.00 01-JAN-00:15 338241.33 07-JUL-09:45
HeatingCoils:EnergyTransfer 172.65 0.00 01-JAN-12:15 227771.13 11-FEB-05:00
PlantLoopHeatingDemand:HVAC 131.92 0.00 01-JAN-12:15 175212.49 11-FEB-05:00
HeatingCoils:PlantLoopHeatingDemand 131.92 0.00 01-JAN-12:15 175212.49 11-FEB-05:00
Boilers:EnergyTransfer 104.80 0.00 01-JAN-00:15 172901.61 11-FEB-05:00



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:57

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 2.358 -17.294 0.000 0.000 3.697 1.087 12.213 20.441 0.000 0.926 0.000 0.000 -6.804 0.000 -5.195 -11.428
G NW APARTMENT 3.519 -14.229 0.000 0.000 3.717 1.087 12.213 13.538 0.000 0.907 0.000 0.000 -6.912 0.000 -4.677 -9.163
OFFICE 1.503 -27.341 0.000 0.000 0.506 29.882 9.495 19.946 0.000 0.654 0.000 0.000 -6.929 0.000 -2.075 -25.642
G NE APARTMENT 3.198 -14.193 0.000 0.000 3.728 1.087 12.213 13.232 0.000 0.907 0.000 0.000 -6.588 0.000 -4.621 -8.962
G N1 APARTMENT 1.582 -10.284 0.000 0.000 3.731 1.087 12.213 5.885 0.000 0.653 0.000 0.000 -4.192 0.000 -3.645 -7.029
G N2 APARTMENT 1.585 -10.290 0.000 0.000 3.731 1.087 12.213 5.885 0.000 0.652 0.000 0.000 -4.189 0.000 -3.642 -7.032
G S1 APARTMENT 0.637 -13.608 0.000 0.000 3.698 1.087 12.213 12.863 0.000 0.662 0.000 0.000 -4.095 0.000 -4.239 -9.217
G S2 APARTMENT 0.604 -13.976 0.000 0.000 3.694 1.087 12.213 12.844 0.000 0.663 0.000 0.000 -4.113 0.000 -4.290 -8.724
F2 SW APARTMENT 1.618 -25.091 0.000 0.000 3.640 1.087 12.213 19.400 0.000 1.261 0.329 0.000 -7.504 0.000 -6.952 -0.000
F2 NW APARTMENT 2.870 -20.681 0.000 0.000 3.675 1.087 12.213 12.812 0.000 1.229 0.663 0.000 -7.583 0.000 -6.285 -0.000
F2 SE APARTMENT 1.253 -26.967 0.000 0.000 3.635 1.087 12.213 19.157 0.000 1.261 2.841 0.000 -7.423 0.000 -7.055 -0.000
F2 NE APARTMENT 2.577 -20.725 0.000 0.000 3.687 1.087 12.213 12.505 0.000 1.229 0.853 0.000 -7.218 0.000 -6.208 -0.000
F2 N1 APARTMENT 0.939 -15.985 0.000 0.000 3.680 1.087 12.213 5.501 0.000 0.858 1.309 0.000 -4.668 0.000 -4.934 -0.000
F2 N2 APARTMENT 0.944 -15.987 0.000 0.000 3.681 1.087 12.213 5.501 0.000 0.858 1.297 0.000 -4.664 0.000 -4.930 -0.000
F2 S1 APARTMENT 0.296 -20.593 0.000 0.000 3.631 1.087 12.213 12.183 0.000 0.881 0.520 0.000 -4.535 0.000 -5.683 -0.000
F2 S2 APARTMENT 0.291 -20.747 0.000 0.000 3.630 1.087 12.213 12.178 0.000 0.882 0.709 0.000 -4.542 0.000 -5.700 -0.000
F3 SW APARTMENT 1.594 -26.249 0.000 0.000 3.633 1.087 12.213 18.933 0.000 1.537 2.752 0.000 -7.681 0.000 -7.820 -0.000
F3 NW APARTMENT 2.851 -21.847 0.000 0.000 3.669 1.087 12.213 12.520 0.000 1.492 2.903 0.000 -7.786 0.000 -7.103 -0.000
F3 SE APARTMENT 1.378 -26.570 0.000 0.000 3.640 1.087 12.213 18.759 0.000 1.535 3.247 0.000 -7.495 0.000 -7.792 -0.000
F3 NE APARTMENT 2.576 -21.897 0.000 0.000 3.681 1.087 12.213 12.215 0.000 1.492 3.062 0.000 -7.411 0.000 -7.018 -0.000
F3 N1 APARTMENT 0.869 -17.309 0.000 0.000 3.670 1.087 12.213 5.371 0.000 1.053 3.441 0.000 -4.819 0.000 -5.577 -0.000
F3 N2 APARTMENT 0.875 -17.308 0.000 0.000 3.671 1.087 12.213 5.371 0.000 1.053 3.424 0.000 -4.814 0.000 -5.571 -0.000
F3 S1 APARTMENT 0.267 -22.048 0.000 0.000 3.619 1.087 12.213 11.875 0.000 1.085 2.938 0.000 -4.661 0.000 -6.374 -0.000
F3 S2 APARTMENT 0.269 -22.085 0.000 0.000 3.619 1.087 12.213 11.873 0.000 1.085 2.977 0.000 -4.661 0.000 -6.377 -0.000
F4 SW APARTMENT 1.719 -26.362 0.000 0.000 3.633 1.087 12.213 18.622 0.000 1.687 3.403 0.000 -7.762 0.000 -8.240 -0.000
F4 NW APARTMENT 3.001 -22.088 0.000 0.000 3.669 1.087 12.213 12.335 0.000 1.637 3.540 0.000 -7.888 0.000 -7.504 -0.000
F4 SE APARTMENT 1.538 -26.471 0.000 0.000 3.642 1.087 12.213 18.463 0.000 1.685 3.581 0.000 -7.554 0.000 -8.184 -0.000
F4 NE APARTMENT 2.710 -22.139 0.000 0.000 3.680 1.087 12.213 12.032 0.000 1.637 3.701 0.000 -7.508 0.000 -7.412 -0.000
F4 N1 APARTMENT 0.895 -17.637 0.000 0.000 3.667 1.087 12.213 5.295 0.000 1.148 4.067 0.000 -4.896 0.000 -5.837 0.000
F4 N2 APARTMENT 0.900 -17.635 0.000 0.000 3.668 1.087 12.213 5.294 0.000 1.147 4.050 0.000 -4.892 0.000 -5.831 -0.000
F4 S1 APARTMENT 0.295 -22.298 0.000 0.000 3.617 1.087 12.213 11.672 0.000 1.183 3.600 0.000 -4.719 0.000 -6.649 -0.000
F4 S2 APARTMENT 0.300 -22.305 0.000 0.000 3.618 1.087 12.213 11.671 0.000 1.184 3.598 0.000 -4.716 0.000 -6.648 -0.000
M SW APARTMENT 1.866 -26.641 0.000 0.000 3.635 1.087 12.213 18.375 0.000 1.808 4.223 0.000 -7.824 0.000 -8.741 -0.000
M NW APARTMENT 3.169 -22.508 0.000 0.000 3.669 1.087 12.213 12.187 0.000 1.752 4.375 0.000 -7.969 0.000 -7.976 -0.000
M SE APARTMENT 1.684 -26.719 0.000 0.000 3.644 1.087 12.213 18.221 0.000 1.805 4.350 0.000 -7.610 0.000 -8.674 -0.000
M NE APARTMENT 2.867 -22.553 0.000 0.000 3.681 1.087 12.213 11.885 0.000 1.752 4.534 0.000 -7.586 0.000 -7.879 -0.000
M N1 APARTMENT 0.955 -18.094 0.000 0.000 3.666 1.087 12.213 5.233 0.000 1.223 4.864 0.000 -4.956 0.000 -6.191 0.000
M N2 APARTMENT 0.959 -18.092 0.000 0.000 3.667 1.087 12.213 5.233 0.000 1.222 4.847 0.000 -4.951 0.000 -6.185 0.000
M S1 APARTMENT 0.336 -22.641 0.000 0.000 3.618 1.087 12.213 11.511 0.000 1.262 4.402 0.000 -4.760 0.000 -7.028 -0.000
M S2 APARTMENT 0.341 -22.639 0.000 0.000 3.618 1.087 12.213 11.511 0.000 1.263 4.391 0.000 -4.757 0.000 -7.026 -0.000
F6 SW APARTMENT 2.146 -25.816 0.000 0.000 3.643 1.087 12.213 18.210 0.000 1.908 3.513 0.000 -7.811 0.000 -9.093 -0.000
F6 NW APARTMENT 3.553 -21.886 0.000 0.000 3.677 1.087 12.213 12.102 0.000 1.849 3.667 0.000 -7.967 0.000 -8.294 -0.000
F6 SE APARTMENT 1.951 -25.888 0.000 0.000 3.653 1.087 12.213 18.060 0.000 1.904 3.633 0.000 -7.595 0.000 -9.017 -0.000
F6 NE APARTMENT 3.247 -21.917 0.000 0.000 3.688 1.087 12.213 11.802 0.000 1.848 3.814 0.000 -7.586 0.000 -8.195 -0.000
F6 N1 APARTMENT 1.159 -17.450 0.000 0.000 3.674 1.087 12.213 5.205 0.000 1.286 4.189 0.000 -4.957 0.000 -6.405 0.000
F6 N2 APARTMENT 1.165 -17.450 0.000 0.000 3.674 1.087 12.213 5.205 0.000 1.285 4.172 0.000 -4.953 0.000 -6.398 0.000
F6 S1 APARTMENT 0.432 -21.798 0.000 0.000 3.626 1.087 12.213 11.405 0.000 1.328 3.730 0.000 -4.751 0.000 -7.272 -0.000
F6 S2 APARTMENT 0.438 -21.796 0.000 0.000 3.627 1.087 12.213 11.405 0.000 1.328 3.715 0.000 -4.748 0.000 -7.269 -0.000
F7 SW APARTMENT 2.389 -25.397 0.000 0.000 3.649 1.087 12.213 18.059 0.000 1.994 3.227 0.000 -7.813 0.000 -9.406 -0.000
F7 NW APARTMENT 3.871 -21.630 0.000 0.000 3.682 1.087 12.213 12.018 0.000 1.932 3.396 0.000 -7.981 0.000 -8.587 -0.000
F7 SE APARTMENT 2.181 -25.465 0.000 0.000 3.659 1.087 12.213 17.911 0.000 1.991 3.345 0.000 -7.595 0.000 -9.325 -0.000
F7 NE APARTMENT 3.559 -21.650 0.000 0.000 3.692 1.087 12.213 11.720 0.000 1.932 3.535 0.000 -7.601 0.000 -8.486 -0.000
F7 N1 APARTMENT 1.334 -17.181 0.000 0.000 3.679 1.087 12.213 5.175 0.000 1.340 3.924 0.000 -4.967 0.000 -6.603 -0.000
F7 N2 APARTMENT 1.338 -17.179 0.000 0.000 3.680 1.087 12.213 5.175 0.000 1.339 3.908 0.000 -4.963 0.000 -6.597 -0.000
F7 S1 APARTMENT 0.527 -21.367 0.000 0.000 3.633 1.087 12.213 11.307 0.000 1.385 3.456 0.000 -4.751 0.000 -7.489 -0.000
F7 S2 APARTMENT 0.533 -21.365 0.000 0.000 3.633 1.087 12.213 11.307 0.000 1.385 3.440 0.000 -4.748 0.000 -7.486 -0.000
F8 SW APARTMENT 2.623 -25.209 0.000 0.000 3.654 1.087 12.213 17.920 0.000 2.077 3.168 0.000 -7.822 0.000 -9.711 -0.000
F8 NW APARTMENT 4.171 -21.577 0.000 0.000 3.686 1.087 12.213 11.939 0.000 2.013 3.352 0.000 -8.004 0.000 -8.878 -0.000
F8 SE APARTMENT 2.409 -25.272 0.000 0.000 3.664 1.087 12.213 17.774 0.000 2.074 3.282 0.000 -7.604 0.000 -9.626 -0.000
F8 NE APARTMENT 3.856 -21.588 0.000 0.000 3.696 1.087 12.213 11.641 0.000 2.012 3.482 0.000 -7.624 0.000 -8.775 -0.000
F8 N1 APARTMENT 1.508 -17.117 0.000 0.000 3.683 1.087 12.213 5.145 0.000 1.394 3.879 0.000 -4.982 0.000 -6.809 -0.000
F8 N2 APARTMENT 1.514 -17.118 0.000 0.000 3.683 1.087 12.213 5.145 0.000 1.394 3.862 0.000 -4.978 0.000 -6.802 -0.000
F8 S1 APARTMENT 0.624 -21.160 0.000 0.000 3.638 1.087 12.213 11.219 0.000 1.442 3.398 0.000 -4.754 0.000 -7.706 -0.001
F8 S2 APARTMENT 0.631 -21.157 0.000 0.000 3.639 1.087 12.213 11.218 0.000 1.442 3.381 0.000 -4.751 0.000 -7.702 -0.000
F9 SW APARTMENT 3.016 -25.586 0.000 0.000 3.658 1.087 12.213 17.793 0.000 2.162 3.483 0.000 -7.837 0.000 -9.989 -0.000
F9 NW APARTMENT 4.667 -22.107 0.000 0.000 3.688 1.087 12.213 11.858 0.000 2.093 3.695 0.000 -8.035 0.000 -9.157 -0.000
F9 SE APARTMENT 2.757 -25.638 0.000 0.000 3.668 1.087 12.213 17.648 0.000 2.159 3.621 0.000 -7.617 0.000 -9.898 -0.000
F9 NE APARTMENT 4.304 -22.100 0.000 0.000 3.698 1.087 12.213 11.561 0.000 2.092 3.846 0.000 -7.653 0.000 -9.047 -0.001
F9 N1 APARTMENT 1.823 -17.562 0.000 0.000 3.685 1.087 12.213 5.112 0.000 1.452 4.201 0.000 -5.000 0.000 -7.009 -0.000
F9 N2 APARTMENT 1.829 -17.562 0.000 0.000 3.686 1.087 12.213 5.111 0.000 1.452 4.185 0.000 -4.996 0.000 -7.003 -0.000
F9 S1 APARTMENT 0.800 -21.450 0.000 0.000 3.644 1.087 12.213 11.140 0.000 1.506 3.718 0.000 -4.759 0.000 -7.898 -0.000
F9 S2 APARTMENT 0.809 -21.451 0.000 0.000 3.644 1.087 12.213 11.140 0.000 1.506 3.703 0.000 -4.756 0.000 -7.894 -0.000
T SW APARTMENT 5.477 -27.735 0.000 0.000 3.679 1.087 12.213 17.361 0.000 2.221 3.469 0.000 -7.558 0.000 -10.213 -0.000
T NW APARTMENT 7.041 -24.236 0.000 0.000 3.699 1.087 12.213 11.492 0.000 2.149 3.809 0.000 -7.808 0.000 -9.446 -0.000
T SE APARTMENT 5.043 -27.546 0.000 0.000 3.689 1.087 12.213 17.230 0.000 2.220 3.563 0.000 -7.358 0.000 -10.141 -0.000
T NE APARTMENT 6.457 -23.999 0.000 0.000 3.711 1.087 12.213 11.228 0.000 2.150 3.945 0.000 -7.456 0.000 -9.334 -0.000
T N1 APARTMENT 3.271 -19.238 0.000 0.000 3.698 1.087 12.213 4.963 0.000 1.492 4.555 0.000 -4.840 0.000 -7.201 -0.000
T N2 APARTMENT 3.284 -19.240 0.000 0.000 3.699 1.087 12.213 4.962 0.000 1.492 4.538 0.000 -4.835 0.000 -7.198 -0.000
T S1 APARTMENT 2.174 -22.981 0.000 0.000 3.667 1.087 12.213 10.906 0.000 1.561 4.047 0.000 -4.611 0.000 -8.062 -0.000
T S2 APARTMENT 2.186 -22.985 0.000 0.000 3.668 1.087 12.213 10.904 0.000 1.561 4.034 0.000 -4.607 0.000 -8.060 -0.000
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 4.733 0.000 5.998 0.000 0.000 -1.564 0.000 -20.333 -5.275
F2 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 2.193 0.000 0.090 0.000 0.000 -1.018 0.000 -0.572 -17.133
F3 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 2.121 0.000 0.103 0.000 0.000 -1.065 0.000 -0.707 -16.891
F4 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 2.074 0.000 0.111 0.000 0.000 -1.091 0.000 -0.803 -16.730
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 32.880 0.000 2.004 0.000 0.101 0.000 0.000 -1.152 0.000 -0.937 -32.896
F6 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 2.028 0.000 0.128 0.000 0.000 -1.101 0.000 -0.927 -16.566
F7 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 2.019 0.000 0.137 0.000 0.000 -1.092 0.000 -0.965 -16.538
F8 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 2.004 0.000 0.143 0.000 0.000 -1.093 0.000 -1.006 -16.487
F9 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.986 0.000 0.143 0.000 0.000 -1.100 0.000 -1.047 -16.422
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 8.151 1.859 0.000 0.082 0.000 0.000 -1.099 0.000 -1.175 -24.259
Total Facility 162.086 -1696.974 0.000 0.000 290.148 296.560 982.450 971.825 0.000 124.396 247.677 0.000 -504.049 0.000 -607.721 -266.408


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 28-SEP-15:15 0.00 -3273.71 0.00 0.00 48.55 45.40 470.89 3655.74 0.00 111.58 0.00 0.00 0.00 0.00 0.00 -1058.46
G NW APARTMENT 01-AUG-17:20 0.00 -3060.74 0.00 0.00 141.81 87.56 588.62 2720.82 0.00 165.43 0.00 0.00 0.00 0.00 0.00 -643.50
OFFICE 28-SEP-13:30 0.00 -4334.05 0.00 0.00 65.20 2345.88 588.62 3235.66 0.00 92.33 0.00 0.00 0.00 0.00 0.00 -1993.63
G NE APARTMENT 03-AUG-10:00 0.00 -2194.21 0.00 0.00 40.69 12.97 406.15 2498.40 0.00 66.08 0.00 0.00 0.00 0.00 0.00 -830.08
G N1 APARTMENT 01-AUG-17:10 0.00 -1537.76 0.00 0.00 141.82 87.56 588.62 752.35 0.00 82.75 0.00 0.00 0.00 0.00 0.00 -115.34
G N2 APARTMENT 01-AUG-17:10 0.00 -1525.83 0.00 0.00 141.82 87.56 588.62 752.59 0.00 82.75 0.00 0.00 0.00 0.00 0.00 -127.51
G S1 APARTMENT 28-OCT-13:30 0.00 -1953.84 0.00 0.00 40.22 12.97 382.60 3215.57 0.00 44.95 0.00 0.00 0.00 0.00 0.00 -1742.48
G S2 APARTMENT 28-OCT-13:30 0.00 -2014.41 0.00 0.00 40.47 12.97 382.60 3217.89 0.00 45.78 0.00 0.00 0.00 0.00 0.00 -1685.31
F2 SW APARTMENT 28-SEP-14:45 0.00 -3818.25 0.00 0.00 40.72 22.70 400.26 3858.36 0.00 155.03 0.00 0.00 0.00 0.00 0.00 -658.83
F2 NW APARTMENT 01-AUG-16:10 0.00 -3498.52 0.00 0.00 84.77 64.86 588.62 3027.10 0.00 309.50 0.00 0.00 0.00 0.00 0.00 -576.33
F2 SE APARTMENT 28-SEP-13:45 0.00 -3452.03 0.00 0.00 40.53 12.97 382.60 3067.99 0.00 139.09 0.00 0.00 0.00 0.00 0.00 -191.16
F2 NE APARTMENT 03-AUG-10:00 0.00 -2630.90 0.00 0.00 40.75 12.97 406.15 2465.85 0.00 95.19 0.00 0.00 0.00 0.00 0.00 -390.02
F2 N1 APARTMENT 01-AUG-17:45 0.00 -1844.65 0.00 0.00 141.81 87.56 588.62 750.73 0.00 166.46 109.47 0.00 0.00 0.00 0.00 0.00
F2 N2 APARTMENT 01-AUG-17:45 0.00 -1835.07 0.00 0.00 141.81 87.56 588.62 750.90 0.00 166.46 99.73 0.00 0.00 0.00 0.00 0.00
F2 S1 APARTMENT 28-OCT-13:30 0.00 -2387.83 0.00 0.00 39.64 12.97 382.60 3109.35 0.00 61.46 0.00 0.00 0.00 0.00 0.00 -1218.19
F2 S2 APARTMENT 28-OCT-13:30 0.00 -2409.92 0.00 0.00 39.70 12.97 382.60 3109.87 0.00 61.74 0.00 0.00 0.00 0.00 0.00 -1196.96
F3 SW APARTMENT 28-SEP-14:45 0.00 -3820.35 0.00 0.00 40.75 22.70 400.26 3808.74 0.00 183.35 0.00 0.00 0.00 0.00 0.00 -635.46
F3 NW APARTMENT 01-AUG-16:10 0.00 -3550.42 0.00 0.00 84.77 64.86 588.62 3006.85 0.00 365.87 0.00 0.00 0.00 0.00 0.00 -560.54
F3 SE APARTMENT 29-OCT-13:45 0.00 -3301.52 0.00 0.00 40.56 12.97 382.60 3142.75 0.00 104.88 0.00 0.00 0.00 0.00 0.00 -382.25
F3 NE APARTMENT 01-JUL-10:00 0.00 -2655.89 0.00 0.00 40.61 12.97 406.15 2415.20 0.00 89.69 0.00 0.00 0.00 0.00 0.00 -308.73
F3 N1 APARTMENT 01-AUG-17:45 0.00 -1887.47 0.00 0.00 141.81 87.56 588.62 751.09 0.00 196.73 121.66 0.00 0.00 0.00 0.00 0.00
F3 N2 APARTMENT 01-AUG-17:45 0.00 -1877.96 0.00 0.00 141.81 87.56 588.62 751.26 0.00 196.72 111.99 0.00 0.00 0.00 0.00 0.00
F3 S1 APARTMENT 13-NOV-13:30 0.00 -2476.07 0.00 0.00 40.75 12.97 388.49 2935.22 0.00 0.00 0.00 0.00 0.00 0.00 -21.68 -879.69
F3 S2 APARTMENT 13-NOV-13:00 0.00 -2481.99 0.00 0.00 40.75 12.97 406.15 3065.94 0.00 0.00 0.00 0.00 0.00 0.00 -46.14 -997.67
F4 SW APARTMENT 31-OCT-15:15 0.00 -3816.20 0.00 0.00 48.91 45.40 470.89 3679.51 0.00 214.18 0.00 0.00 0.00 0.00 0.00 -642.70
F4 NW APARTMENT 01-AUG-16:10 0.00 -3589.78 0.00 0.00 84.77 64.86 588.62 2991.75 0.00 408.31 0.00 0.00 0.00 0.00 0.00 -548.52
F4 SE APARTMENT 29-OCT-13:45 0.00 -3306.44 0.00 0.00 40.55 12.97 382.60 3114.02 0.00 116.71 0.00 0.00 0.00 0.00 0.00 -360.42
F4 NE APARTMENT 04-AUG-14:00 0.00 -2707.92 0.00 0.00 40.76 12.97 382.60 1618.19 0.00 554.07 99.32 0.00 0.00 0.00 0.00 0.00
F4 N1 APARTMENT 01-AUG-17:45 0.00 -1917.51 0.00 0.00 141.81 87.56 588.62 751.12 0.00 219.49 128.91 0.00 0.00 0.00 0.00 0.00
F4 N2 APARTMENT 01-AUG-17:45 0.00 -1908.05 0.00 0.00 141.81 87.56 588.62 751.29 0.00 219.48 119.29 0.00 0.00 0.00 0.00 0.00
F4 S1 APARTMENT 13-NOV-13:30 0.00 -2510.36 0.00 0.00 40.75 12.97 388.49 2912.45 0.00 0.00 0.00 0.00 0.00 0.00 -25.53 -818.77
F4 S2 APARTMENT 13-NOV-13:30 0.00 -2513.24 0.00 0.00 40.75 12.97 388.49 2912.39 0.00 0.00 0.00 0.00 0.00 0.00 -25.53 -815.83
M SW APARTMENT 28-SEP-14:45 0.00 -3831.77 0.00 0.00 40.75 22.70 400.26 3737.35 0.00 221.68 0.00 0.00 0.00 0.00 0.00 -590.98
M NW APARTMENT 01-AUG-16:10 0.00 -3643.45 0.00 0.00 84.77 64.86 588.62 2978.84 0.00 443.05 0.00 0.00 0.00 0.00 0.00 -516.67
M SE APARTMENT 29-OCT-13:30 0.00 -3343.35 0.00 0.00 40.60 12.97 382.60 3196.15 0.00 128.91 0.00 0.00 0.00 0.00 0.00 -417.88
M NE APARTMENT 04-AUG-14:00 0.00 -2751.71 0.00 0.00 40.76 12.97 382.60 1613.06 0.00 600.37 101.95 0.00 0.00 0.00 0.00 0.00
M N1 APARTMENT 01-AUG-17:45 0.00 -1964.37 0.00 0.00 141.81 87.56 588.62 750.58 0.00 238.13 157.68 0.00 0.00 0.00 0.00 0.00
M N2 APARTMENT 01-AUG-17:45 0.00 -1954.95 0.00 0.00 141.81 87.56 588.62 750.75 0.00 238.12 148.09 0.00 0.00 0.00 0.00 0.00
M S1 APARTMENT 28-OCT-13:30 0.00 -2529.88 0.00 0.00 39.76 12.97 382.60 2976.41 0.00 88.14 0.00 0.00 0.00 0.00 0.00 -970.01
M S2 APARTMENT 28-OCT-13:30 0.00 -2536.05 0.00 0.00 39.78 12.97 382.60 2976.65 0.00 88.30 0.00 0.00 0.00 0.00 0.00 -964.26
F6 SW APARTMENT 28-SEP-14:45 0.00 -3789.67 0.00 0.00 40.75 22.70 400.26 3711.08 0.00 236.37 0.00 0.00 0.00 0.00 0.00 -621.49
F6 NW APARTMENT 01-AUG-16:10 0.00 -3633.90 0.00 0.00 84.77 64.86 588.62 2969.42 0.00 472.77 0.00 0.00 0.00 0.00 0.00 -546.53
F6 SE APARTMENT 29-OCT-13:30 0.00 -3319.04 0.00 0.00 40.67 12.97 382.60 3175.80 0.00 137.96 0.00 0.00 0.00 0.00 0.00 -430.98
F6 NE APARTMENT 02-AUG-16:10 0.00 -2741.36 0.00 0.00 84.77 64.86 588.62 1378.88 0.00 461.27 162.96 0.00 0.00 0.00 0.00 0.00
F6 N1 APARTMENT 01-AUG-17:45 0.00 -1947.70 0.00 0.00 141.81 87.56 588.62 751.05 0.00 254.01 124.66 0.00 0.00 0.00 0.00 0.00
F6 N2 APARTMENT 01-AUG-17:45 0.00 -1938.37 0.00 0.00 141.81 87.56 588.62 751.21 0.00 254.00 115.17 0.00 0.00 0.00 0.00 0.00
F6 S1 APARTMENT 28-OCT-13:30 0.00 -2509.91 0.00 0.00 39.86 12.97 382.60 2949.45 0.00 94.54 0.00 0.00 0.00 0.00 0.00 -969.51
F6 S2 APARTMENT 28-OCT-13:30 0.00 -2515.99 0.00 0.00 39.88 12.97 382.60 2949.68 0.00 94.70 0.00 0.00 0.00 0.00 0.00 -963.85
F7 SW APARTMENT 28-SEP-14:45 0.00 -3769.75 0.00 0.00 40.75 22.70 400.26 3687.34 0.00 249.25 0.00 0.00 0.00 0.00 0.00 -630.55
F7 NW APARTMENT 01-AUG-16:10 0.00 -3643.66 0.00 0.00 84.77 64.86 588.62 2960.57 0.00 498.92 0.00 0.00 0.00 0.00 0.00 -554.08
F7 SE APARTMENT 29-OCT-13:15 0.00 -3309.31 0.00 0.00 40.70 12.97 382.60 3205.42 0.00 148.02 0.00 0.00 0.00 0.00 0.00 -480.41
F7 NE APARTMENT 02-AUG-16:10 0.00 -2757.81 0.00 0.00 84.77 64.86 588.62 1379.40 0.00 486.79 153.38 0.00 0.00 0.00 0.00 0.00
F7 N1 APARTMENT 01-AUG-17:45 0.00 -1951.86 0.00 0.00 141.81 87.56 588.62 750.99 0.00 267.99 114.88 0.00 0.00 0.00 0.00 0.00
F7 N2 APARTMENT 01-AUG-17:45 0.00 -1942.59 0.00 0.00 141.81 87.56 588.62 751.16 0.00 267.99 105.46 0.00 0.00 0.00 0.00 0.00
F7 S1 APARTMENT 28-OCT-13:30 0.00 -2511.62 0.00 0.00 39.97 12.97 382.60 2925.21 0.00 100.32 0.00 0.00 0.00 0.00 0.00 -949.45
F7 S2 APARTMENT 28-OCT-13:30 0.00 -2517.64 0.00 0.00 39.99 12.97 382.60 2925.45 0.00 100.48 0.00 0.00 0.00 0.00 0.00 -943.85
F8 SW APARTMENT 28-SEP-14:45 0.00 -3760.98 0.00 0.00 40.75 22.70 400.26 3665.73 0.00 260.76 0.00 0.00 0.00 0.00 0.00 -629.22
F8 NW APARTMENT 01-AUG-16:10 0.00 -3664.46 0.00 0.00 84.77 64.86 588.62 2952.22 0.00 522.37 0.00 0.00 0.00 0.00 0.00 -548.37
F8 SE APARTMENT 29-OCT-12:45 0.00 -3303.95 0.00 0.00 40.69 12.97 388.49 3312.81 0.00 140.41 0.00 0.00 0.00 0.00 0.00 -591.42
F8 NE APARTMENT 02-AUG-16:10 0.00 -2784.89 0.00 0.00 84.77 64.86 588.62 1379.26 0.00 509.67 157.71 0.00 0.00 0.00 0.00 0.00
F8 N1 APARTMENT 01-AUG-17:45 0.00 -1970.24 0.00 0.00 141.81 87.56 588.62 750.57 0.00 280.57 121.12 0.00 0.00 0.00 0.00 0.00
F8 N2 APARTMENT 01-AUG-17:45 0.00 -1961.04 0.00 0.00 141.81 87.56 588.62 750.74 0.00 280.56 111.75 0.00 0.00 0.00 0.00 0.00
F8 S1 APARTMENT 28-OCT-13:30 0.00 -2527.52 0.00 0.00 40.09 12.97 382.60 2903.85 0.00 105.78 0.00 0.00 0.00 0.00 0.00 -917.78
F8 S2 APARTMENT 28-OCT-13:30 0.00 -2533.50 0.00 0.00 40.11 12.97 382.60 2904.08 0.00 105.96 0.00 0.00 0.00 0.00 0.00 -912.23
F9 SW APARTMENT 01-AUG-15:30 0.00 -3865.47 0.00 0.00 48.90 45.40 470.89 3061.04 0.00 605.69 0.00 0.00 0.00 0.00 0.00 -366.47
F9 NW APARTMENT 01-AUG-16:10 0.00 -3770.97 0.00 0.00 84.77 64.86 588.62 2941.44 0.00 543.69 0.00 0.00 0.00 0.00 0.00 -452.41
F9 SE APARTMENT 28-SEP-13:30 0.00 -3352.79 0.00 0.00 40.72 12.97 382.60 3031.81 0.00 230.68 0.00 0.00 0.00 0.00 0.00 -346.00
F9 NE APARTMENT 02-AUG-16:10 0.00 -2900.82 0.00 0.00 84.77 64.86 588.62 1375.58 0.00 530.49 256.51 0.00 0.00 0.00 0.00 0.00
F9 N1 APARTMENT 01-AUG-17:45 0.00 -2083.13 0.00 0.00 141.81 87.56 588.62 747.98 0.00 292.18 224.98 0.00 0.00 0.00 0.00 0.00
F9 N2 APARTMENT 01-AUG-17:45 0.00 -2073.88 0.00 0.00 141.81 87.56 588.62 748.15 0.00 292.18 215.56 0.00 0.00 0.00 0.00 0.00
F9 S1 APARTMENT 28-OCT-13:30 0.00 -2611.86 0.00 0.00 40.39 12.97 382.60 2886.30 0.00 112.31 0.00 0.00 0.00 0.00 0.00 -822.72
F9 S2 APARTMENT 28-OCT-13:30 0.00 -2617.71 0.00 0.00 40.41 12.97 382.60 2886.51 0.00 112.48 0.00 0.00 0.00 0.00 0.00 -817.27
T SW APARTMENT 01-AUG-15:15 0.00 -4760.03 0.00 0.00 48.90 45.40 470.89 3008.26 0.00 609.64 576.93 0.00 0.00 0.00 0.00 0.00
T NW APARTMENT 01-AUG-16:10 0.00 -4606.09 0.00 0.00 84.77 64.86 588.62 2886.59 0.00 563.25 418.00 0.00 0.00 0.00 0.00 0.00
T SE APARTMENT 28-SEP-13:30 0.00 -4082.16 0.00 0.00 40.76 12.97 382.60 2974.78 0.00 239.10 431.95 0.00 0.00 0.00 0.00 0.00
T NE APARTMENT 02-AUG-16:10 0.00 -3596.44 0.00 0.00 84.77 64.86 588.62 1334.05 0.00 549.58 974.56 0.00 0.00 0.00 0.00 0.00
T N1 APARTMENT 02-AUG-15:15 0.00 -2755.42 0.00 0.00 48.90 45.40 470.89 892.66 0.00 252.06 1045.51 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 02-AUG-15:30 0.00 -2752.26 0.00 0.00 48.90 45.40 470.89 871.81 0.00 286.10 1029.16 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 28-OCT-13:30 0.00 -3417.16 0.00 0.00 40.75 12.97 382.60 2846.84 0.00 119.41 14.59 0.00 0.00 0.00 0.00 0.00
T S2 APARTMENT 28-OCT-13:30 0.00 -3416.07 0.00 0.00 40.75 12.97 382.60 2846.84 0.00 119.41 13.49 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 01-AUG-15:30 0.00 -211116.55 0.00 0.00 3926.90 11666.77 38153.89 135020.29 0.00 33901.50 0.00 0.00 0.00 0.00 0.00 -11552.80


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 11-FEB-05:00 1923.01 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 440.11 0.00 -1749.84 0.00 -1046.08 0.00
G NW APARTMENT 11-FEB-05:00 2019.99 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 350.06 0.00 -1756.77 0.00 -1046.08 0.00
OFFICE 11-FEB-07:00 1842.36 0.00 0.00 0.00 0.00 469.18 194.24 0.00 0.00 0.00 190.02 0.00 -1759.27 0.00 -936.54 0.00
G NE APARTMENT 11-FEB-05:00 2037.16 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 318.81 0.00 -1742.69 0.00 -1046.09 0.00
G N1 APARTMENT 16-MAR-15:55 1349.01 0.00 0.00 0.00 55.44 45.40 470.89 48.36 0.00 0.00 0.00 0.00 0.00 0.00 -1256.83 -712.27
G N2 APARTMENT 16-MAR-15:55 1371.53 0.00 0.00 0.00 55.47 45.40 470.89 48.74 0.00 0.00 0.00 0.00 0.00 0.00 -1255.89 -736.15
G S1 APARTMENT 17-MAR-08:25 1342.08 0.00 0.00 0.00 46.33 12.97 394.37 33.13 0.00 0.00 0.00 0.00 0.00 0.00 -1188.86 -640.02
G S2 APARTMENT 17-MAR-08:25 1163.18 0.00 0.00 0.00 46.11 12.97 394.37 30.05 0.00 0.00 0.00 0.00 0.00 0.00 -1195.50 -451.19
F2 SW APARTMENT 11-FEB-05:00 2093.43 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 820.10 0.00 -1841.92 0.00 -1504.40 0.00
F2 NW APARTMENT 11-FEB-04:15 2325.67 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 641.73 0.00 -1827.74 0.00 -1572.46 0.00
F2 SE APARTMENT 11-FEB-05:00 2012.75 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 878.97 0.00 -1820.12 0.00 -1504.40 0.00
F2 NE APARTMENT 11-FEB-04:00 2351.48 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 606.46 0.00 -1784.62 0.00 -1593.15 0.00
F2 N1 APARTMENT 03-JAN-07:55 1513.25 0.00 0.00 0.00 157.37 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -180.64 0.00 -1412.83 -501.91
F2 N2 APARTMENT 16-MAR-12:40 1525.70 0.00 0.00 0.00 45.88 12.97 388.49 157.46 0.00 0.00 0.00 0.00 0.00 0.00 -1512.75 -617.76
F2 S1 APARTMENT 16-MAR-16:00 1583.22 0.00 0.00 0.00 52.61 45.40 470.89 38.94 0.00 0.00 0.00 0.00 0.00 0.00 -1630.82 -560.25
F2 S2 APARTMENT 16-MAR-16:00 1600.78 0.00 0.00 0.00 52.51 45.40 470.89 37.78 0.00 0.00 0.00 0.00 0.00 0.00 -1631.04 -576.33
F3 SW APARTMENT 11-FEB-05:00 2321.78 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 908.47 0.00 -1880.99 0.00 -1782.06 0.00
F3 NW APARTMENT 11-FEB-04:00 2586.17 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 742.69 0.00 -1861.43 0.00 -1887.25 0.00
F3 SE APARTMENT 11-FEB-05:00 2319.10 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 879.40 0.00 -1849.24 0.00 -1782.06 0.00
F3 NE APARTMENT 11-FEB-04:00 2614.24 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 679.06 0.00 -1825.88 0.00 -1887.25 0.00
F3 N1 APARTMENT 03-JAN-07:55 1697.58 0.00 0.00 0.00 156.64 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -190.15 0.00 -1555.25 -533.59
F3 N2 APARTMENT 03-JAN-07:55 1694.92 0.00 0.00 0.00 156.67 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -190.04 0.00 -1555.21 -531.11
F3 S1 APARTMENT 16-MAR-16:00 1596.88 0.00 0.00 0.00 52.23 45.40 470.89 12.68 0.00 0.00 0.00 0.00 0.00 0.00 -1828.39 -349.69
F3 S2 APARTMENT 16-MAR-16:00 1599.94 0.00 0.00 0.00 52.23 45.40 470.89 12.74 0.00 0.00 0.00 0.00 0.00 0.00 -1828.41 -352.79
F4 SW APARTMENT 11-FEB-05:00 2552.32 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 913.28 0.00 -1905.47 0.00 -1992.93 0.00
F4 NW APARTMENT 11-FEB-04:00 2827.16 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 754.12 0.00 -1890.48 0.00 -2110.64 0.00
F4 SE APARTMENT 11-FEB-04:45 2568.07 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 878.10 0.00 -1854.63 0.00 -2024.34 0.00
F4 NE APARTMENT 11-FEB-04:00 2850.50 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 691.67 0.00 -1851.36 0.00 -2110.64 0.00
F4 N1 APARTMENT 16-MAR-12:40 1875.32 0.00 0.00 0.00 45.81 12.97 388.49 130.01 0.00 0.00 0.00 0.00 0.00 0.00 -1810.58 -642.02
F4 N2 APARTMENT 16-MAR-12:40 1911.68 0.00 0.00 0.00 45.86 12.97 388.49 130.65 0.00 0.00 0.00 0.00 0.00 0.00 -1809.29 -680.35
F4 S1 APARTMENT 16-MAR-12:45 1575.97 0.00 0.00 0.00 43.63 12.97 388.49 105.52 0.00 0.00 0.00 0.00 0.00 0.00 -2079.44 -47.14
F4 S2 APARTMENT 16-MAR-12:45 1573.56 0.00 0.00 0.00 43.67 12.97 388.49 106.03 0.00 0.00 0.00 0.00 0.00 0.00 -2079.41 -45.30
M SW APARTMENT 11-FEB-04:15 2741.40 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 973.06 0.00 -1882.08 0.00 -2265.18 0.00
M NW APARTMENT 11-FEB-04:00 3019.59 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 768.38 0.00 -1912.76 0.00 -2295.05 0.00
M SE APARTMENT 11-FEB-04:00 2761.55 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 939.66 0.00 -1825.99 0.00 -2295.05 0.00
M NE APARTMENT 11-FEB-04:00 3038.57 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 707.75 0.00 -1871.09 0.00 -2295.05 0.00
M N1 APARTMENT 16-MAR-12:40 2014.60 0.00 0.00 0.00 45.87 12.97 388.49 123.28 0.00 0.00 0.00 0.00 0.00 0.00 -1924.31 -660.89
M N2 APARTMENT 16-MAR-12:40 2003.28 0.00 0.00 0.00 45.91 12.97 388.49 123.87 0.00 0.00 0.00 0.00 0.00 0.00 -1924.20 -650.32
M S1 APARTMENT 16-MAR-12:45 1588.58 0.00 0.00 0.00 43.80 12.97 388.49 95.28 0.00 0.00 96.91 0.00 0.00 0.00 -2226.03 0.00
M S2 APARTMENT 16-MAR-12:45 1585.01 0.00 0.00 0.00 43.84 12.97 388.49 95.94 0.00 0.00 99.73 0.00 0.00 0.00 -2225.98 0.00
F6 SW APARTMENT 11-FEB-04:00 2961.79 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 952.35 0.00 -1879.75 0.00 -2454.22 0.00
F6 NW APARTMENT 11-FEB-04:00 3232.33 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 730.15 0.00 -1928.10 0.00 -2454.22 0.00
F6 SE APARTMENT 11-FEB-04:00 2978.96 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 891.62 0.00 -1836.19 0.00 -2454.22 0.00
F6 NE APARTMENT 11-FEB-04:00 3244.92 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 674.01 0.00 -1884.54 0.00 -2454.22 0.00
F6 N1 APARTMENT 16-MAR-12:40 1985.21 0.00 0.00 0.00 46.24 12.97 388.49 122.04 0.00 0.00 0.00 0.00 0.00 0.00 -2026.29 -528.65
F6 N2 APARTMENT 16-MAR-12:40 1975.11 0.00 0.00 0.00 46.28 12.97 388.49 122.56 0.00 0.00 0.00 0.00 0.00 0.00 -2026.20 -519.21
F6 S1 APARTMENT 16-MAR-12:40 1568.74 0.00 0.00 0.00 44.30 12.97 388.49 92.48 0.00 0.00 277.08 0.00 0.00 0.00 -2384.06 0.00
F6 S2 APARTMENT 16-MAR-12:40 1607.27 0.00 0.00 0.00 44.34 12.97 388.49 93.20 0.00 0.00 236.79 0.00 0.00 0.00 -2383.05 0.00
F7 SW APARTMENT 11-FEB-04:00 3144.70 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 921.54 0.00 -1890.62 0.00 -2595.46 0.00
F7 NW APARTMENT 11-FEB-04:00 3407.37 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 709.82 0.00 -1941.56 0.00 -2595.46 0.00
F7 SE APARTMENT 11-FEB-04:00 3158.13 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 862.95 0.00 -1845.45 0.00 -2595.46 0.00
F7 NE APARTMENT 11-FEB-04:00 3415.37 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 656.68 0.00 -1896.42 0.00 -2595.46 0.00
F7 N1 APARTMENT 23-JAN-14:10 2095.08 0.00 0.00 0.00 47.42 12.97 382.60 0.00 0.00 0.00 0.00 0.00 -4.64 0.00 -2320.09 -213.34
F7 N2 APARTMENT 23-JAN-14:10 2092.22 0.00 0.00 0.00 47.42 12.97 382.60 0.00 0.00 0.00 0.00 0.00 -4.84 0.00 -2320.09 -210.28
F7 S1 APARTMENT 17-MAR-08:25 1865.22 0.00 0.00 0.00 45.21 12.97 394.37 0.00 0.00 0.00 0.00 0.00 -61.87 0.00 -2017.83 -238.07
F7 S2 APARTMENT 17-MAR-08:25 1901.34 0.00 0.00 0.00 45.25 12.97 394.37 0.00 0.00 0.00 0.00 0.00 -61.15 0.00 -2016.85 -275.94
F8 SW APARTMENT 11-FEB-04:00 3297.77 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 906.24 0.00 -1900.62 0.00 -2723.22 0.00
F8 NW APARTMENT 11-FEB-04:00 3554.79 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 702.41 0.00 -1953.81 0.00 -2723.22 0.00
F8 SE APARTMENT 11-FEB-04:00 3308.41 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 849.08 0.00 -1854.10 0.00 -2723.22 0.00
F8 NE APARTMENT 11-FEB-04:00 3559.79 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 650.92 0.00 -1907.32 0.00 -2723.23 0.00
F8 N1 APARTMENT 23-JAN-14:10 2210.17 0.00 0.00 0.00 47.42 12.97 382.60 0.00 0.00 0.00 0.00 0.00 -6.99 0.00 -2420.75 -225.42
F8 N2 APARTMENT 23-JAN-14:10 2207.00 0.00 0.00 0.00 47.42 12.97 382.60 0.00 0.00 0.00 0.00 0.00 -7.18 0.00 -2420.75 -222.06
F8 S1 APARTMENT 17-MAR-08:25 2242.93 0.00 0.00 0.00 45.53 12.97 394.37 0.00 0.00 0.00 0.00 0.00 -61.59 0.00 -2090.91 -543.31
F8 S2 APARTMENT 17-MAR-08:25 2276.97 0.00 0.00 0.00 45.57 12.97 394.37 0.00 0.00 0.00 0.00 0.00 -60.92 0.00 -2089.99 -578.98
F9 SW APARTMENT 11-FEB-04:00 3468.29 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 860.29 0.00 -1908.00 0.00 -2840.41 0.00
F9 NW APARTMENT 11-FEB-04:00 3711.29 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 672.29 0.00 -1963.00 0.00 -2840.41 0.00
F9 SE APARTMENT 11-FEB-04:00 3476.90 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 803.96 0.00 -1860.28 0.00 -2840.41 0.00
F9 NE APARTMENT 11-FEB-04:00 3712.58 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 623.28 0.00 -1915.28 0.00 -2840.41 0.00
F9 N1 APARTMENT 23-JAN-14:10 2345.25 0.00 0.00 0.00 47.42 12.97 382.60 0.00 0.00 0.00 0.00 0.00 -7.89 0.00 -2514.66 -265.69
F9 N2 APARTMENT 23-JAN-14:10 2341.04 0.00 0.00 0.00 47.42 12.97 382.60 0.00 0.00 0.00 0.00 0.00 -8.09 0.00 -2514.66 -261.28
F9 S1 APARTMENT 16-MAR-12:55 2597.33 0.00 0.00 0.00 45.24 12.97 388.49 97.33 0.00 0.00 0.00 0.00 0.00 0.00 -2512.83 -628.53
F9 S2 APARTMENT 16-MAR-12:55 2632.17 0.00 0.00 0.00 45.28 12.97 388.49 98.01 0.00 0.00 0.00 0.00 0.00 0.00 -2511.92 -665.00
T SW APARTMENT 11-FEB-04:00 4417.90 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 0.00 0.00 -1863.00 0.00 -2948.82 -25.91
T NW APARTMENT 11-FEB-04:00 4591.06 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 0.00 0.00 -1920.40 0.00 -2948.82 -141.67
T SE APARTMENT 11-FEB-04:00 4405.35 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 0.00 0.00 -1816.78 0.00 -2948.82 -59.58
T NE APARTMENT 11-FEB-04:00 4581.17 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 0.00 0.00 -1874.38 0.00 -2948.82 -177.80
T N1 APARTMENT 11-FEB-04:00 2736.65 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 0.00 0.00 -1167.58 0.00 -1778.72 -210.18
T N2 APARTMENT 11-FEB-04:00 2739.35 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 0.00 0.00 -1167.48 0.00 -1778.72 -212.98
T S1 APARTMENT 16-MAR-12:55 2784.04 0.00 0.00 0.00 45.69 12.97 388.49 101.07 0.00 0.00 0.00 0.00 0.00 0.00 -2602.48 -729.78
T S2 APARTMENT 16-MAR-12:55 2778.99 0.00 0.00 0.00 45.72 12.97 388.49 101.60 0.00 0.00 0.00 0.00 0.00 0.00 -2602.41 -725.36
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 11-FEB-04:00 180739.20 0.00 0.00 0.00 14984.00 6715.87 17923.60 0.00 0.00 0.00 49716.03 0.00 -121500.52 0.00 -148578.19 0.00



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:57

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:57

Sec1.1A-General Information

Data
Weather File Houston Bush Intercontinental TX USA TMY3 WMO#=722430
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 7836.48
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.50
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
F2 SW APARTMENT 88.25 88.25 0.00 168.00
F2 NW APARTMENT 88.25 88.25 0.00 168.00
F2 SE APARTMENT 88.25 88.25 0.00 168.00
F2 NE APARTMENT 88.25 88.25 0.00 168.00
F2 N1 APARTMENT 88.25 88.25 0.00 168.00
F2 N2 APARTMENT 88.25 88.25 0.00 168.00
F2 S1 APARTMENT 88.25 88.25 0.00 168.00
F2 S2 APARTMENT 88.25 88.25 0.00 168.00
F3 SW APARTMENT 88.25 88.25 0.00 168.00
F3 NW APARTMENT 88.25 88.25 0.00 168.00
F3 SE APARTMENT 88.25 88.25 0.00 168.00
F3 NE APARTMENT 88.25 88.25 0.00 168.00
F3 N1 APARTMENT 88.25 88.25 0.00 168.00
F3 N2 APARTMENT 88.25 88.25 0.00 168.00
F3 S1 APARTMENT 88.25 88.25 0.00 168.00
F3 S2 APARTMENT 88.25 88.25 0.00 168.00
F4 SW APARTMENT 88.25 88.25 0.00 168.00
F4 NW APARTMENT 88.25 88.25 0.00 168.00
F4 SE APARTMENT 88.25 88.25 0.00 168.00
F4 NE APARTMENT 88.25 88.25 0.00 168.00
F4 N1 APARTMENT 88.25 88.25 0.00 168.00
F4 N2 APARTMENT 88.25 88.25 0.00 168.00
F4 S1 APARTMENT 88.25 88.25 0.00 168.00
F4 S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
F6 SW APARTMENT 88.25 88.25 0.00 168.00
F6 NW APARTMENT 88.25 88.25 0.00 168.00
F6 SE APARTMENT 88.25 88.25 0.00 168.00
F6 NE APARTMENT 88.25 88.25 0.00 168.00
F6 N1 APARTMENT 88.25 88.25 0.00 168.00
F6 N2 APARTMENT 88.25 88.25 0.00 168.00
F6 S1 APARTMENT 88.25 88.25 0.00 168.00
F6 S2 APARTMENT 88.25 88.25 0.00 168.00
F7 SW APARTMENT 88.25 88.25 0.00 168.00
F7 NW APARTMENT 88.25 88.25 0.00 168.00
F7 SE APARTMENT 88.25 88.25 0.00 168.00
F7 NE APARTMENT 88.25 88.25 0.00 168.00
F7 N1 APARTMENT 88.25 88.25 0.00 168.00
F7 N2 APARTMENT 88.25 88.25 0.00 168.00
F7 S1 APARTMENT 88.25 88.25 0.00 168.00
F7 S2 APARTMENT 88.25 88.25 0.00 168.00
F8 SW APARTMENT 88.25 88.25 0.00 168.00
F8 NW APARTMENT 88.25 88.25 0.00 168.00
F8 SE APARTMENT 88.25 88.25 0.00 168.00
F8 NE APARTMENT 88.25 88.25 0.00 168.00
F8 N1 APARTMENT 88.25 88.25 0.00 168.00
F8 N2 APARTMENT 88.25 88.25 0.00 168.00
F8 S1 APARTMENT 88.25 88.25 0.00 168.00
F8 S2 APARTMENT 88.25 88.25 0.00 168.00
F9 SW APARTMENT 88.25 88.25 0.00 168.00
F9 NW APARTMENT 88.25 88.25 0.00 168.00
F9 SE APARTMENT 88.25 88.25 0.00 168.00
F9 NE APARTMENT 88.25 88.25 0.00 168.00
F9 N1 APARTMENT 88.25 88.25 0.00 168.00
F9 N2 APARTMENT 88.25 88.25 0.00 168.00
F9 S1 APARTMENT 88.25 88.25 0.00 168.00
F9 S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
G CORRIDOR 77.66 0.00 77.66 0.00
F2 CORRIDOR 77.66 0.00 77.66 0.00
F3 CORRIDOR 77.66 0.00 77.66 0.00
F4 CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
F6 CORRIDOR 77.66 0.00 77.66 0.00
F7 CORRIDOR 77.66 0.00 77.66 0.00
F8 CORRIDOR 77.66 0.00 77.66 0.00
F9 CORRIDOR 77.66 0.00 77.66 0.00
T CORRIDOR 77.66 0.00 77.66 0.00
Totals 7836.48 7059.89 776.58  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 47.25
Number of hours cooling loads not met 313.50
Number of hours not met 360.75


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 296.56 13120.46 0.00 0.00 0.00 0.00
Exterior Lighting 162.86 0.00 0.00 0.00 0.00 0.00
Space Heating 49.16 0.00 140.95 205316.53 0.00 0.00
Space Cooling 924.90 90227.27 0.00 0.00 0.00 0.00
Pumps 73.12 2453.60 0.00 0.00 0.00 0.00
Heat Rejection 46.83 3653.19 0.00 0.00 0.00 0.00
Fans-Interior 659.86 20924.02 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 0.00 0.00 918.44 72689.02 0.00 0.00
Receptacle Equipment 1137.32 57042.02 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 3386.78   1059.39   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 1137.32 3386.78
Natural Gas 0.00 1059.39
Additional 0.00 0.00
Total 1137.32 4446.16


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 37.84
Space Heating 6.27
Space Cooling 118.02
Fans-Interior 84.20
Service Water Heating 0.00
Receptacle Equipment 145.13
Miscellaneous 40.70
Subtotal 432.18


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 17.99
Service Water Heating 117.20
Miscellaneous -0.00
Subtotal 135.19


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 6.67
Space Heating 4.28
Space Cooling 20.80
Fans-Interior 14.84
Service Water Heating 20.66
Receptacle Equipment 25.58
Miscellaneous 7.17



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:57

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.252480
G NW APARTMENT DIRECT AIR 0.258263
OFFICE DIRECT AIR 0.344380
G NE APARTMENT DIRECT AIR 0.204253
G N1 APARTMENT DIRECT AIR 0.130073
G N2 APARTMENT DIRECT AIR 0.128983
G S1 APARTMENT DIRECT AIR 0.127901
G S2 APARTMENT DIRECT AIR 0.133629
F2 SW APARTMENT DIRECT AIR 0.296815
F2 NW APARTMENT DIRECT AIR 0.302203
F2 SE APARTMENT DIRECT AIR 0.269410
F2 NE APARTMENT DIRECT AIR 0.242948
F2 N1 APARTMENT DIRECT AIR 0.158633
F2 N2 APARTMENT DIRECT AIR 0.157773
F2 S1 APARTMENT DIRECT AIR 0.157276
F2 S2 APARTMENT DIRECT AIR 0.159245
F3 SW APARTMENT DIRECT AIR 0.297920
F3 NW APARTMENT DIRECT AIR 0.303478
F3 SE APARTMENT DIRECT AIR 0.251132
F3 NE APARTMENT DIRECT AIR 0.244751
F3 N1 APARTMENT DIRECT AIR 0.161255
F3 N2 APARTMENT DIRECT AIR 0.160404
F3 S1 APARTMENT DIRECT AIR 0.160212
F3 S2 APARTMENT DIRECT AIR 0.161002
F4 SW APARTMENT DIRECT AIR 0.299129
F4 NW APARTMENT DIRECT AIR 0.304622
F4 SE APARTMENT DIRECT AIR 0.250010
F4 NE APARTMENT DIRECT AIR 0.245512
F4 N1 APARTMENT DIRECT AIR 0.163045
F4 N2 APARTMENT DIRECT AIR 0.162201
F4 S1 APARTMENT DIRECT AIR 0.161945
F4 S2 APARTMENT DIRECT AIR 0.162552
M SW APARTMENT DIRECT AIR 0.302131
M NW APARTMENT DIRECT AIR 0.307643
M SE APARTMENT DIRECT AIR 0.252508
M NE APARTMENT DIRECT AIR 0.248227
M N1 APARTMENT DIRECT AIR 0.166486
M N2 APARTMENT DIRECT AIR 0.165647
M S1 APARTMENT DIRECT AIR 0.165257
M S2 APARTMENT DIRECT AIR 0.165833
F6 SW APARTMENT DIRECT AIR 0.299663
F6 NW APARTMENT DIRECT AIR 0.305044
F6 SE APARTMENT DIRECT AIR 0.249858
F6 NE APARTMENT DIRECT AIR 0.245461
F6 N1 APARTMENT DIRECT AIR 0.164469
F6 N2 APARTMENT DIRECT AIR 0.163640
F6 S1 APARTMENT DIRECT AIR 0.163275
F6 S2 APARTMENT DIRECT AIR 0.163843
F7 SW APARTMENT DIRECT AIR 0.299171
F7 NW APARTMENT DIRECT AIR 0.304497
F7 SE APARTMENT DIRECT AIR 0.249176
F7 NE APARTMENT DIRECT AIR 0.244741
F7 N1 APARTMENT DIRECT AIR 0.164358
F7 N2 APARTMENT DIRECT AIR 0.163536
F7 S1 APARTMENT DIRECT AIR 0.163118
F7 S2 APARTMENT DIRECT AIR 0.163680
F8 SW APARTMENT DIRECT AIR 0.300045
F8 NW APARTMENT DIRECT AIR 0.305335
F8 SE APARTMENT DIRECT AIR 0.249844
F8 NE APARTMENT DIRECT AIR 0.245353
F8 N1 APARTMENT DIRECT AIR 0.165582
F8 N2 APARTMENT DIRECT AIR 0.164767
F8 S1 APARTMENT DIRECT AIR 0.164225
F8 S2 APARTMENT DIRECT AIR 0.164784
F9 SW APARTMENT DIRECT AIR 0.310054
F9 NW APARTMENT DIRECT AIR 0.315567
F9 SE APARTMENT DIRECT AIR 0.254950
F9 NE APARTMENT DIRECT AIR 0.250119
F9 N1 APARTMENT DIRECT AIR 0.175239
F9 N2 APARTMENT DIRECT AIR 0.174424
F9 S1 APARTMENT DIRECT AIR 0.171279
F9 S2 APARTMENT DIRECT AIR 0.171829
T SW APARTMENT DIRECT AIR 0.382080
T NW APARTMENT DIRECT AIR 0.381499
T SE APARTMENT DIRECT AIR 0.319003
T NE APARTMENT DIRECT AIR 0.307674
T N1 APARTMENT DIRECT AIR 0.229530
T N2 APARTMENT DIRECT AIR 0.229513
T S1 APARTMENT DIRECT AIR 0.248503
T S2 APARTMENT DIRECT AIR 0.249019


Branch

Maximum Flow Rate [m3/s]
AIRLOOP G SW MAIN BRANCH 0.252480
AIRLOOP G NW MAIN BRANCH 0.258263
AIRLOOP OFFICE MAIN BRANCH 0.344380
AIRLOOP G NE MAIN BRANCH 0.204253
AIRLOOP G N1 MAIN BRANCH 0.130073
AIRLOOP G N2 MAIN BRANCH 0.128983
AIRLOOP G S1 MAIN BRANCH 0.127901
AIRLOOP G S2 MAIN BRANCH 0.133629
AIRLOOP F2 SW MAIN BRANCH 0.296815
AIRLOOP F2 NW MAIN BRANCH 0.302203
AIRLOOP F2 SE MAIN BRANCH 0.269410
AIRLOOP F2 NE MAIN BRANCH 0.242948
AIRLOOP F2 N1 MAIN BRANCH 0.158633
AIRLOOP F2 N2 MAIN BRANCH 0.157773
AIRLOOP F2 S1 MAIN BRANCH 0.157276
AIRLOOP F2 S2 MAIN BRANCH 0.159245
AIRLOOP F3 SW MAIN BRANCH 0.297920
AIRLOOP F3 NW MAIN BRANCH 0.303478
AIRLOOP F3 SE MAIN BRANCH 0.251132
AIRLOOP F3 NE MAIN BRANCH 0.244751
AIRLOOP F3 N1 MAIN BRANCH 0.161255
AIRLOOP F3 N2 MAIN BRANCH 0.160404
AIRLOOP F3 S1 MAIN BRANCH 0.160212
AIRLOOP F3 S2 MAIN BRANCH 0.161002
AIRLOOP F4 SW MAIN BRANCH 0.299129
AIRLOOP F4 NW MAIN BRANCH 0.304622
AIRLOOP F4 SE MAIN BRANCH 0.250010
AIRLOOP F4 NE MAIN BRANCH 0.245512
AIRLOOP F4 N1 MAIN BRANCH 0.163045
AIRLOOP F4 N2 MAIN BRANCH 0.162201
AIRLOOP F4 S1 MAIN BRANCH 0.161945
AIRLOOP F4 S2 MAIN BRANCH 0.162552
AIRLOOP M SW MAIN BRANCH 0.302131
AIRLOOP M NW MAIN BRANCH 0.307643
AIRLOOP M SE MAIN BRANCH 0.252508
AIRLOOP M NE MAIN BRANCH 0.248227
AIRLOOP M N1 MAIN BRANCH 0.166486
AIRLOOP M N2 MAIN BRANCH 0.165647
AIRLOOP M S1 MAIN BRANCH 0.165257
AIRLOOP M S2 MAIN BRANCH 0.165833
AIRLOOP F6 SW MAIN BRANCH 0.299663
AIRLOOP F6 NW MAIN BRANCH 0.305044
AIRLOOP F6 SE MAIN BRANCH 0.249858
AIRLOOP F6 NE MAIN BRANCH 0.245461
AIRLOOP F6 N1 MAIN BRANCH 0.164469
AIRLOOP F6 N2 MAIN BRANCH 0.163640
AIRLOOP F6 S1 MAIN BRANCH 0.163275
AIRLOOP F6 S2 MAIN BRANCH 0.163843
AIRLOOP F7 SW MAIN BRANCH 0.299171
AIRLOOP F7 NW MAIN BRANCH 0.304497
AIRLOOP F7 SE MAIN BRANCH 0.249176
AIRLOOP F7 NE MAIN BRANCH 0.244741
AIRLOOP F7 N1 MAIN BRANCH 0.164358
AIRLOOP F7 N2 MAIN BRANCH 0.163536
AIRLOOP F7 S1 MAIN BRANCH 0.163118
AIRLOOP F7 S2 MAIN BRANCH 0.163680
AIRLOOP F8 SW MAIN BRANCH 0.300045
AIRLOOP F8 NW MAIN BRANCH 0.305335
AIRLOOP F8 SE MAIN BRANCH 0.249844
AIRLOOP F8 NE MAIN BRANCH 0.245353
AIRLOOP F8 N1 MAIN BRANCH 0.165582
AIRLOOP F8 N2 MAIN BRANCH 0.164767
AIRLOOP F8 S1 MAIN BRANCH 0.164225
AIRLOOP F8 S2 MAIN BRANCH 0.164784
AIRLOOP F9 SW MAIN BRANCH 0.310054
AIRLOOP F9 NW MAIN BRANCH 0.315567
AIRLOOP F9 SE MAIN BRANCH 0.254950
AIRLOOP F9 NE MAIN BRANCH 0.250119
AIRLOOP F9 N1 MAIN BRANCH 0.175239
AIRLOOP F9 N2 MAIN BRANCH 0.174424
AIRLOOP F9 S1 MAIN BRANCH 0.171279
AIRLOOP F9 S2 MAIN BRANCH 0.171829
AIRLOOP T SW MAIN BRANCH 0.382080
AIRLOOP T NW MAIN BRANCH 0.381499
AIRLOOP T SE MAIN BRANCH 0.319003
AIRLOOP T NE MAIN BRANCH 0.307674
AIRLOOP T N1 MAIN BRANCH 0.229530
AIRLOOP T N2 MAIN BRANCH 0.229513
AIRLOOP T S1 MAIN BRANCH 0.248503
AIRLOOP T S2 MAIN BRANCH 0.249019


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
AIRLOOP G SW 0.252480
AIRLOOP G NW 0.258263
AIRLOOP OFFICE 0.344380
AIRLOOP G NE 0.204253
AIRLOOP G N1 0.130073
AIRLOOP G N2 0.128983
AIRLOOP G S1 0.127901
AIRLOOP G S2 0.133629
AIRLOOP F2 SW 0.296815
AIRLOOP F2 NW 0.302203
AIRLOOP F2 SE 0.269410
AIRLOOP F2 NE 0.242948
AIRLOOP F2 N1 0.158633
AIRLOOP F2 N2 0.157773
AIRLOOP F2 S1 0.157276
AIRLOOP F2 S2 0.159245
AIRLOOP F3 SW 0.297920
AIRLOOP F3 NW 0.303478
AIRLOOP F3 SE 0.251132
AIRLOOP F3 NE 0.244751
AIRLOOP F3 N1 0.161255
AIRLOOP F3 N2 0.160404
AIRLOOP F3 S1 0.160212
AIRLOOP F3 S2 0.161002
AIRLOOP F4 SW 0.299129
AIRLOOP F4 NW 0.304622
AIRLOOP F4 SE 0.250010
AIRLOOP F4 NE 0.245512
AIRLOOP F4 N1 0.163045
AIRLOOP F4 N2 0.162201
AIRLOOP F4 S1 0.161945
AIRLOOP F4 S2 0.162552
AIRLOOP M SW 0.302131
AIRLOOP M NW 0.307643
AIRLOOP M SE 0.252508
AIRLOOP M NE 0.248227
AIRLOOP M N1 0.166486
AIRLOOP M N2 0.165647
AIRLOOP M S1 0.165257
AIRLOOP M S2 0.165833
AIRLOOP F6 SW 0.299663
AIRLOOP F6 NW 0.305044
AIRLOOP F6 SE 0.249858
AIRLOOP F6 NE 0.245461
AIRLOOP F6 N1 0.164469
AIRLOOP F6 N2 0.163640
AIRLOOP F6 S1 0.163275
AIRLOOP F6 S2 0.163843
AIRLOOP F7 SW 0.299171
AIRLOOP F7 NW 0.304497
AIRLOOP F7 SE 0.249176
AIRLOOP F7 NE 0.244741
AIRLOOP F7 N1 0.164358
AIRLOOP F7 N2 0.163536
AIRLOOP F7 S1 0.163118
AIRLOOP F7 S2 0.163680
AIRLOOP F8 SW 0.300045
AIRLOOP F8 NW 0.305335
AIRLOOP F8 SE 0.249844
AIRLOOP F8 NE 0.245353
AIRLOOP F8 N1 0.165582
AIRLOOP F8 N2 0.164767
AIRLOOP F8 S1 0.164225
AIRLOOP F8 S2 0.164784
AIRLOOP F9 SW 0.310054
AIRLOOP F9 NW 0.315567
AIRLOOP F9 SE 0.254950
AIRLOOP F9 NE 0.250119
AIRLOOP F9 N1 0.175239
AIRLOOP F9 N2 0.174424
AIRLOOP F9 S1 0.171279
AIRLOOP F9 S2 0.171829
AIRLOOP T SW 0.382080
AIRLOOP T NW 0.381499
AIRLOOP T SE 0.319003
AIRLOOP T NE 0.307674
AIRLOOP T N1 0.229530
AIRLOOP T N2 0.229513
AIRLOOP T S1 0.248503
AIRLOOP T S2 0.249019


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
AIRLOOP G SW OA CONTROLLER 0.252480 0.025952
AIRLOOP G NW OA CONTROLLER 0.258263 0.025952
AIRLOOP OFFICE OA CONTROLLER 0.344380 0.038103
AIRLOOP G NE OA CONTROLLER 0.204253 0.025952
AIRLOOP G N1 OA CONTROLLER 0.130073 0.025952
AIRLOOP G N2 OA CONTROLLER 0.128983 0.025952
AIRLOOP G S1 OA CONTROLLER 0.127901 0.025952
AIRLOOP G S2 OA CONTROLLER 0.133629 0.025952
AIRLOOP F2 SW OA CONTROLLER 0.296815 0.025952
AIRLOOP F2 NW OA CONTROLLER 0.302203 0.025952
AIRLOOP F2 SE OA CONTROLLER 0.269410 0.025952
AIRLOOP F2 NE OA CONTROLLER 0.242948 0.025952
AIRLOOP F2 N1 OA CONTROLLER 0.158633 0.025952
AIRLOOP F2 N2 OA CONTROLLER 0.157773 0.025952
AIRLOOP F2 S1 OA CONTROLLER 0.157276 0.025952
AIRLOOP F2 S2 OA CONTROLLER 0.159245 0.025952
AIRLOOP F3 SW OA CONTROLLER 0.297920 0.025952
AIRLOOP F3 NW OA CONTROLLER 0.303478 0.025952
AIRLOOP F3 SE OA CONTROLLER 0.251132 0.025952
AIRLOOP F3 NE OA CONTROLLER 0.244751 0.025952
AIRLOOP F3 N1 OA CONTROLLER 0.161255 0.025952
AIRLOOP F3 N2 OA CONTROLLER 0.160404 0.025952
AIRLOOP F3 S1 OA CONTROLLER 0.160212 0.025952
AIRLOOP F3 S2 OA CONTROLLER 0.161002 0.025952
AIRLOOP F4 SW OA CONTROLLER 0.299129 0.025952
AIRLOOP F4 NW OA CONTROLLER 0.304622 0.025952
AIRLOOP F4 SE OA CONTROLLER 0.250010 0.025952
AIRLOOP F4 NE OA CONTROLLER 0.245512 0.025952
AIRLOOP F4 N1 OA CONTROLLER 0.163045 0.025952
AIRLOOP F4 N2 OA CONTROLLER 0.162201 0.025952
AIRLOOP F4 S1 OA CONTROLLER 0.161945 0.025952
AIRLOOP F4 S2 OA CONTROLLER 0.162552 0.025952
AIRLOOP M SW OA CONTROLLER 0.302131 0.025952
AIRLOOP M NW OA CONTROLLER 0.307643 0.025952
AIRLOOP M SE OA CONTROLLER 0.252508 0.025952
AIRLOOP M NE OA CONTROLLER 0.248227 0.025952
AIRLOOP M N1 OA CONTROLLER 0.166486 0.025952
AIRLOOP M N2 OA CONTROLLER 0.165647 0.025952
AIRLOOP M S1 OA CONTROLLER 0.165257 0.025952
AIRLOOP M S2 OA CONTROLLER 0.165833 0.025952
AIRLOOP F6 SW OA CONTROLLER 0.299663 0.025952
AIRLOOP F6 NW OA CONTROLLER 0.305044 0.025952
AIRLOOP F6 SE OA CONTROLLER 0.249858 0.025952
AIRLOOP F6 NE OA CONTROLLER 0.245461 0.025952
AIRLOOP F6 N1 OA CONTROLLER 0.164469 0.025952
AIRLOOP F6 N2 OA CONTROLLER 0.163640 0.025952
AIRLOOP F6 S1 OA CONTROLLER 0.163275 0.025952
AIRLOOP F6 S2 OA CONTROLLER 0.163843 0.025952
AIRLOOP F7 SW OA CONTROLLER 0.299171 0.025952
AIRLOOP F7 NW OA CONTROLLER 0.304497 0.025952
AIRLOOP F7 SE OA CONTROLLER 0.249176 0.025952
AIRLOOP F7 NE OA CONTROLLER 0.244741 0.025952
AIRLOOP F7 N1 OA CONTROLLER 0.164358 0.025952
AIRLOOP F7 N2 OA CONTROLLER 0.163536 0.025952
AIRLOOP F7 S1 OA CONTROLLER 0.163118 0.025952
AIRLOOP F7 S2 OA CONTROLLER 0.163680 0.025952
AIRLOOP F8 SW OA CONTROLLER 0.300045 0.025952
AIRLOOP F8 NW OA CONTROLLER 0.305335 0.025952
AIRLOOP F8 SE OA CONTROLLER 0.249844 0.025952
AIRLOOP F8 NE OA CONTROLLER 0.245353 0.025952
AIRLOOP F8 N1 OA CONTROLLER 0.165582 0.025952
AIRLOOP F8 N2 OA CONTROLLER 0.164767 0.025952
AIRLOOP F8 S1 OA CONTROLLER 0.164225 0.025952
AIRLOOP F8 S2 OA CONTROLLER 0.164784 0.025952
AIRLOOP F9 SW OA CONTROLLER 0.310054 0.025952
AIRLOOP F9 NW OA CONTROLLER 0.315567 0.025952
AIRLOOP F9 SE OA CONTROLLER 0.254950 0.025952
AIRLOOP F9 NE OA CONTROLLER 0.250119 0.025952
AIRLOOP F9 N1 OA CONTROLLER 0.175239 0.025952
AIRLOOP F9 N2 OA CONTROLLER 0.174424 0.025952
AIRLOOP F9 S1 OA CONTROLLER 0.171279 0.025952
AIRLOOP F9 S2 OA CONTROLLER 0.171829 0.025952
AIRLOOP T SW OA CONTROLLER 0.382080 0.025952
AIRLOOP T NW OA CONTROLLER 0.381499 0.025952
AIRLOOP T SE OA CONTROLLER 0.319003 0.025952
AIRLOOP T NE OA CONTROLLER 0.307674 0.025952
AIRLOOP T N1 OA CONTROLLER 0.229530 0.025952
AIRLOOP T N2 OA CONTROLLER 0.229513 0.025952
AIRLOOP T S1 OA CONTROLLER 0.248503 0.025952
AIRLOOP T S2 OA CONTROLLER 0.249019 0.025952


COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity [W] Rated Sensible Cooling Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP COOLING MODE AIRLOOP G SW 0.252480 4608.67 3128.39 0.000101
HEAT PUMP COOLING MODE AIRLOOP G NW 0.258263 4679.76 3185.09 0.000102
HEAT PUMP COOLING MODE AIRLOOP OFFICE 0.344380 6206.62 4237.38 0.000136
HEAT PUMP COOLING MODE AIRLOOP G NE 0.204253 3858.00 2571.04 0.000084
HEAT PUMP COOLING MODE AIRLOOP G N1 0.130073 2735.61 1742.48 0.000060
HEAT PUMP COOLING MODE AIRLOOP G N2 0.128983 2719.38 1730.42 0.000059
HEAT PUMP COOLING MODE AIRLOOP G S1 0.127901 2760.70 1745.35 0.000060
HEAT PUMP COOLING MODE AIRLOOP G S2 0.133629 2844.61 1808.67 0.000062
HEAT PUMP COOLING MODE AIRLOOP F2 SW 0.296815 5325.85 3639.85 0.000116
HEAT PUMP COOLING MODE AIRLOOP F2 NW 0.302203 5397.15 3694.82 0.000118
HEAT PUMP COOLING MODE AIRLOOP F2 SE 0.269410 4908.14 3327.10 0.000107
HEAT PUMP COOLING MODE AIRLOOP F2 NE 0.242948 4499.55 3022.68 0.000098
HEAT PUMP COOLING MODE AIRLOOP F2 N1 0.158633 3205.84 2075.61 0.000070
HEAT PUMP COOLING MODE AIRLOOP F2 N2 0.157773 3193.10 2066.10 0.000070
HEAT PUMP COOLING MODE AIRLOOP F2 S1 0.157276 3237.26 2085.92 0.000071
HEAT PUMP COOLING MODE AIRLOOP F2 S2 0.159245 3265.91 2107.62 0.000071
HEAT PUMP COOLING MODE AIRLOOP F3 SW 0.297920 5394.79 3668.54 0.000118
HEAT PUMP COOLING MODE AIRLOOP F3 NW 0.303478 5468.75 3725.42 0.000119
HEAT PUMP COOLING MODE AIRLOOP F3 SE 0.251132 4696.98 3143.00 0.000103
HEAT PUMP COOLING MODE AIRLOOP F3 NE 0.244751 4576.48 3058.90 0.000100
HEAT PUMP COOLING MODE AIRLOOP F3 N1 0.161255 3272.61 2114.19 0.000071
HEAT PUMP COOLING MODE AIRLOOP F3 N2 0.160404 3259.96 2104.76 0.000071
HEAT PUMP COOLING MODE AIRLOOP F3 S1 0.160212 3308.04 2127.80 0.000072
HEAT PUMP COOLING MODE AIRLOOP F3 S2 0.161002 3319.52 2136.49 0.000073
HEAT PUMP COOLING MODE AIRLOOP F4 SW 0.299129 5451.62 3694.22 0.000119
HEAT PUMP COOLING MODE AIRLOOP F4 NW 0.304622 5524.82 3750.42 0.000121
HEAT PUMP COOLING MODE AIRLOOP F4 SE 0.250010 4718.56 3142.93 0.000103
HEAT PUMP COOLING MODE AIRLOOP F4 NE 0.245512 4633.39 3083.82 0.000101
HEAT PUMP COOLING MODE AIRLOOP F4 N1 0.163045 3320.05 2141.18 0.000073
HEAT PUMP COOLING MODE AIRLOOP F4 N2 0.162201 3307.46 2131.82 0.000072
HEAT PUMP COOLING MODE AIRLOOP F4 S1 0.161945 3354.28 2154.07 0.000073
HEAT PUMP COOLING MODE AIRLOOP F4 S2 0.162552 3363.09 2160.73 0.000073
HEAT PUMP COOLING MODE AIRLOOP M SW 0.302131 5526.84 3737.31 0.000121
HEAT PUMP COOLING MODE AIRLOOP M NW 0.307643 5600.46 3793.75 0.000122
HEAT PUMP COOLING MODE AIRLOOP M SE 0.252508 4785.39 3180.37 0.000105
HEAT PUMP COOLING MODE AIRLOOP M NE 0.248227 4703.28 3123.64 0.000103
HEAT PUMP COOLING MODE AIRLOOP M N1 0.166486 3387.85 2185.00 0.000074
HEAT PUMP COOLING MODE AIRLOOP M N2 0.165647 3375.33 2175.71 0.000074
HEAT PUMP COOLING MODE AIRLOOP M S1 0.165257 3419.96 2196.49 0.000075
HEAT PUMP COOLING MODE AIRLOOP M S2 0.165833 3428.32 2202.82 0.000075
HEAT PUMP COOLING MODE AIRLOOP F6 SW 0.299663 5523.95 3721.49 0.000121
HEAT PUMP COOLING MODE AIRLOOP F6 NW 0.305044 5590.33 3773.87 0.000122
HEAT PUMP COOLING MODE AIRLOOP F6 SE 0.249858 4772.72 3159.74 0.000104
HEAT PUMP COOLING MODE AIRLOOP F6 NE 0.245461 4688.82 3101.74 0.000102
HEAT PUMP COOLING MODE AIRLOOP F6 N1 0.164469 3372.72 2167.85 0.000074
HEAT PUMP COOLING MODE AIRLOOP F6 N2 0.163640 3360.28 2158.65 0.000073
HEAT PUMP COOLING MODE AIRLOOP F6 S1 0.163275 3405.06 2179.51 0.000074
HEAT PUMP COOLING MODE AIRLOOP F6 S2 0.163843 3413.32 2185.74 0.000075
HEAT PUMP COOLING MODE AIRLOOP F7 SW 0.299171 5540.59 3723.67 0.000121
HEAT PUMP COOLING MODE AIRLOOP F7 NW 0.304497 5606.28 3775.47 0.000122
HEAT PUMP COOLING MODE AIRLOOP F7 SE 0.249176 4785.33 3159.70 0.000105
HEAT PUMP COOLING MODE AIRLOOP F7 NE 0.244741 4700.78 3101.28 0.000103
HEAT PUMP COOLING MODE AIRLOOP F7 N1 0.164358 3383.77 2171.06 0.000074
HEAT PUMP COOLING MODE AIRLOOP F7 N2 0.163536 3371.40 2161.93 0.000074
HEAT PUMP COOLING MODE AIRLOOP F7 S1 0.163118 3415.24 2182.10 0.000075
HEAT PUMP COOLING MODE AIRLOOP F7 S2 0.163680 3423.44 2188.28 0.000075
HEAT PUMP COOLING MODE AIRLOOP F8 SW 0.300045 5574.45 3740.09 0.000122
HEAT PUMP COOLING MODE AIRLOOP F8 NW 0.305335 5639.71 3791.51 0.000123
HEAT PUMP COOLING MODE AIRLOOP F8 SE 0.249844 4815.18 3173.73 0.000105
HEAT PUMP COOLING MODE AIRLOOP F8 NE 0.245353 4729.75 3114.70 0.000103
HEAT PUMP COOLING MODE AIRLOOP F8 N1 0.165582 3413.26 2188.54 0.000075
HEAT PUMP COOLING MODE AIRLOOP F8 N2 0.164767 3400.99 2179.49 0.000074
HEAT PUMP COOLING MODE AIRLOOP F8 S1 0.164225 3442.85 2198.25 0.000075
HEAT PUMP COOLING MODE AIRLOOP F8 S2 0.164784 3451.01 2204.39 0.000075
HEAT PUMP COOLING MODE AIRLOOP F9 SW 0.310054 5733.40 3853.76 0.000125
HEAT PUMP COOLING MODE AIRLOOP F9 NW 0.315567 5807.39 3910.27 0.000127
HEAT PUMP COOLING MODE AIRLOOP F9 SE 0.254950 4908.53 3236.15 0.000107
HEAT PUMP COOLING MODE AIRLOOP F9 NE 0.250119 4818.08 3173.35 0.000105
HEAT PUMP COOLING MODE AIRLOOP F9 N1 0.175239 3567.04 2298.80 0.000078
HEAT PUMP COOLING MODE AIRLOOP F9 N2 0.174424 3554.79 2289.74 0.000078
HEAT PUMP COOLING MODE AIRLOOP F9 S1 0.171279 3560.38 2281.19 0.000078
HEAT PUMP COOLING MODE AIRLOOP F9 S2 0.171829 3568.40 2287.23 0.000078
HEAT PUMP COOLING MODE AIRLOOP T SW 0.382080 6798.46 4655.54 0.000149
HEAT PUMP COOLING MODE AIRLOOP T NW 0.381499 6785.88 4646.86 0.000148
HEAT PUMP COOLING MODE AIRLOOP T SE 0.319003 5913.18 3973.93 0.000129
HEAT PUMP COOLING MODE AIRLOOP T NE 0.307674 5693.60 3821.80 0.000124
HEAT PUMP COOLING MODE AIRLOOP T N1 0.229530 4423.93 2927.63 0.000097
HEAT PUMP COOLING MODE AIRLOOP T N2 0.229513 4423.44 2927.36 0.000097
HEAT PUMP COOLING MODE AIRLOOP T S1 0.248503 4699.16 3136.60 0.000103
HEAT PUMP COOLING MODE AIRLOOP T S2 0.249019 4706.44 3142.23 0.000103


AirLoopHVAC:UnitaryHeatPump:WaterToAir

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Supplemental Heating Coil Nominal Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
AIRLOOP G SW DXAC HEAT PUMP 0.252480 0.252480 0.252480 0.252480 4608.67 4608.67 2729.40 1.00
AIRLOOP G NW DXAC HEAT PUMP 0.258263 0.258263 0.258263 0.258263 4679.76 4679.76 2722.15 1.00
AIRLOOP OFFICE DXAC HEAT PUMP 0.344380 0.344380 0.344380 0.344380 6206.62 6206.62 3402.45 1.00
AIRLOOP G NE DXAC HEAT PUMP 0.204253 0.204253 0.204253 0.204253 3858.00 3858.00 2722.15 1.00
AIRLOOP G N1 DXAC HEAT PUMP 0.130073 0.130073 0.130073 0.130073 2735.61 2735.61 1969.25 1.00
AIRLOOP G N2 DXAC HEAT PUMP 0.128983 0.128983 0.128983 0.128983 2719.38 2719.38 1969.25 1.00
AIRLOOP G S1 DXAC HEAT PUMP 0.127901 0.127901 0.127901 0.127901 2760.70 2760.70 1974.32 1.00
AIRLOOP G S2 DXAC HEAT PUMP 0.133629 0.133629 0.133629 0.133629 2844.61 2844.61 1980.66 1.00
AIRLOOP F2 SW DXAC HEAT PUMP 0.296815 0.296815 0.296815 0.296815 5325.85 5325.85 2721.67 1.00
AIRLOOP F2 NW DXAC HEAT PUMP 0.302203 0.302203 0.302203 0.302203 5397.15 5397.15 2714.59 1.00
AIRLOOP F2 SE DXAC HEAT PUMP 0.269410 0.269410 0.269410 0.269410 4908.14 4908.14 2740.79 1.00
AIRLOOP F2 NE DXAC HEAT PUMP 0.242948 0.242948 0.242948 0.242948 4499.55 4499.55 2714.59 1.00
AIRLOOP F2 N1 DXAC HEAT PUMP 0.158633 0.158633 0.158633 0.158633 3205.84 3205.84 1811.93 1.00
AIRLOOP F2 N2 DXAC HEAT PUMP 0.157773 0.157773 0.157773 0.157773 3193.10 3193.10 1811.93 1.00
AIRLOOP F2 S1 DXAC HEAT PUMP 0.157276 0.157276 0.157276 0.157276 3237.26 3237.26 1821.83 1.00
AIRLOOP F2 S2 DXAC HEAT PUMP 0.159245 0.159245 0.159245 0.159245 3265.91 3265.91 1823.15 1.00
AIRLOOP F3 SW DXAC HEAT PUMP 0.297920 0.297920 0.297920 0.297920 5394.79 5394.79 2745.26 1.00
AIRLOOP F3 NW DXAC HEAT PUMP 0.303478 0.303478 0.303478 0.303478 5468.75 5468.75 2741.58 1.00
AIRLOOP F3 SE DXAC HEAT PUMP 0.251132 0.251132 0.251132 0.251132 4696.98 4696.98 2747.49 1.00
AIRLOOP F3 NE DXAC HEAT PUMP 0.244751 0.244751 0.244751 0.244751 4576.48 4576.48 2741.58 1.00
AIRLOOP F3 N1 DXAC HEAT PUMP 0.161255 0.161255 0.161255 0.161255 3272.61 3272.61 1797.72 1.00
AIRLOOP F3 N2 DXAC HEAT PUMP 0.160404 0.160404 0.160404 0.160404 3259.96 3259.96 1797.72 1.00
AIRLOOP F3 S1 DXAC HEAT PUMP 0.160212 0.160212 0.160212 0.160212 3308.04 3308.04 1802.04 1.00
AIRLOOP F3 S2 DXAC HEAT PUMP 0.161002 0.161002 0.161002 0.161002 3319.52 3319.52 1802.26 1.00
AIRLOOP F4 SW DXAC HEAT PUMP 0.299129 0.299129 0.299129 0.299129 5451.62 5451.62 2802.27 1.00
AIRLOOP F4 NW DXAC HEAT PUMP 0.304622 0.304622 0.304622 0.304622 5524.82 5524.82 2801.60 1.00
AIRLOOP F4 SE DXAC HEAT PUMP 0.250010 0.250010 0.250010 0.250010 4718.56 4718.56 2802.52 1.00
AIRLOOP F4 NE DXAC HEAT PUMP 0.245512 0.245512 0.245512 0.245512 4633.39 4633.39 2801.60 1.00
AIRLOOP F4 N1 DXAC HEAT PUMP 0.163045 0.163045 0.163045 0.163045 3320.05 3320.05 1824.72 1.00
AIRLOOP F4 N2 DXAC HEAT PUMP 0.162201 0.162201 0.162201 0.162201 3307.46 3307.46 1824.72 1.00
AIRLOOP F4 S1 DXAC HEAT PUMP 0.161945 0.161945 0.161945 0.161945 3354.28 3354.28 1825.72 1.00
AIRLOOP F4 S2 DXAC HEAT PUMP 0.162552 0.162552 0.162552 0.162552 3363.09 3363.09 1825.75 1.00
AIRLOOP M SW DXAC HEAT PUMP 0.302131 0.302131 0.302131 0.302131 5526.84 5526.84 2837.60 1.00
AIRLOOP M NW DXAC HEAT PUMP 0.307643 0.307643 0.307643 0.307643 5600.46 5600.46 2838.34 1.00
AIRLOOP M SE DXAC HEAT PUMP 0.252508 0.252508 0.252508 0.252508 4785.39 4785.39 2837.63 1.00
AIRLOOP M NE DXAC HEAT PUMP 0.248227 0.248227 0.248227 0.248227 4703.28 4703.28 2838.34 1.00
AIRLOOP M N1 DXAC HEAT PUMP 0.166486 0.166486 0.166486 0.166486 3387.85 3387.85 1835.93 1.00
AIRLOOP M N2 DXAC HEAT PUMP 0.165647 0.165647 0.165647 0.165647 3375.33 3375.33 1835.93 1.00
AIRLOOP M S1 DXAC HEAT PUMP 0.165257 0.165257 0.165257 0.165257 3419.96 3419.96 1835.43 1.00
AIRLOOP M S2 DXAC HEAT PUMP 0.165833 0.165833 0.165833 0.165833 3428.32 3428.32 1835.43 1.00
AIRLOOP F6 SW DXAC HEAT PUMP 0.299663 0.299663 0.299663 0.299663 5523.95 5523.95 2926.03 1.00
AIRLOOP F6 NW DXAC HEAT PUMP 0.305044 0.305044 0.305044 0.305044 5590.33 5590.33 2929.62 1.00
AIRLOOP F6 SE DXAC HEAT PUMP 0.249858 0.249858 0.249858 0.249858 4772.72 4772.72 2926.04 1.00
AIRLOOP F6 NE DXAC HEAT PUMP 0.245461 0.245461 0.245461 0.245461 4688.82 4688.82 2929.62 1.00
AIRLOOP F6 N1 DXAC HEAT PUMP 0.164469 0.164469 0.164469 0.164469 3372.72 3372.72 1902.67 1.00
AIRLOOP F6 N2 DXAC HEAT PUMP 0.163640 0.163640 0.163640 0.163640 3360.28 3360.28 1902.67 1.00
AIRLOOP F6 S1 DXAC HEAT PUMP 0.163275 0.163275 0.163275 0.163275 3405.06 3405.06 1899.30 1.00
AIRLOOP F6 S2 DXAC HEAT PUMP 0.163843 0.163843 0.163843 0.163843 3413.32 3413.32 1899.30 1.00
AIRLOOP F7 SW DXAC HEAT PUMP 0.299171 0.299171 0.299171 0.299171 5540.59 5540.59 2989.08 1.00
AIRLOOP F7 NW DXAC HEAT PUMP 0.304497 0.304497 0.304497 0.304497 5606.28 5606.28 2994.24 1.00
AIRLOOP F7 SE DXAC HEAT PUMP 0.249176 0.249176 0.249176 0.249176 4785.33 4785.33 2989.08 1.00
AIRLOOP F7 NE DXAC HEAT PUMP 0.244741 0.244741 0.244741 0.244741 4700.78 4700.78 2994.24 1.00
AIRLOOP F7 N1 DXAC HEAT PUMP 0.164358 0.164358 0.164358 0.164358 3383.77 3383.77 1947.11 1.00
AIRLOOP F7 N2 DXAC HEAT PUMP 0.163536 0.163536 0.163536 0.163536 3371.40 3371.40 1947.11 1.00
AIRLOOP F7 S1 DXAC HEAT PUMP 0.163118 0.163118 0.163118 0.163118 3415.24 3415.24 1942.14 1.00
AIRLOOP F7 S2 DXAC HEAT PUMP 0.163680 0.163680 0.163680 0.163680 3423.44 3423.44 1942.14 1.00
AIRLOOP F8 SW DXAC HEAT PUMP 0.300045 0.300045 0.300045 0.300045 5574.45 5574.45 3053.65 1.00
AIRLOOP F8 NW DXAC HEAT PUMP 0.305335 0.305335 0.305335 0.305335 5639.71 5639.71 3060.05 1.00
AIRLOOP F8 SE DXAC HEAT PUMP 0.249844 0.249844 0.249844 0.249844 4815.18 4815.18 3053.65 1.00
AIRLOOP F8 NE DXAC HEAT PUMP 0.245353 0.245353 0.245353 0.245353 4729.75 4729.75 3060.05 1.00
AIRLOOP F8 N1 DXAC HEAT PUMP 0.165582 0.165582 0.165582 0.165582 3413.26 3413.26 1994.93 1.00
AIRLOOP F8 N2 DXAC HEAT PUMP 0.164767 0.164767 0.164767 0.164767 3400.99 3400.99 1994.93 1.00
AIRLOOP F8 S1 DXAC HEAT PUMP 0.164225 0.164225 0.164225 0.164225 3442.85 3442.85 1988.72 1.00
AIRLOOP F8 S2 DXAC HEAT PUMP 0.164784 0.164784 0.164784 0.164784 3451.01 3451.01 1988.72 1.00
AIRLOOP F9 SW DXAC HEAT PUMP 0.310054 0.310054 0.310054 0.310054 5733.40 5733.40 3215.62 1.00
AIRLOOP F9 NW DXAC HEAT PUMP 0.315567 0.315567 0.315567 0.315567 5807.39 5807.39 3221.28 1.00
AIRLOOP F9 SE DXAC HEAT PUMP 0.254950 0.254950 0.254950 0.254950 4908.53 4908.53 3215.62 1.00
AIRLOOP F9 NE DXAC HEAT PUMP 0.250119 0.250119 0.250119 0.250119 4818.08 4818.08 3221.28 1.00
AIRLOOP F9 N1 DXAC HEAT PUMP 0.175239 0.175239 0.175239 0.175239 3567.04 3567.04 2132.63 1.00
AIRLOOP F9 N2 DXAC HEAT PUMP 0.174424 0.174424 0.174424 0.174424 3554.79 3554.79 2132.63 1.00
AIRLOOP F9 S1 DXAC HEAT PUMP 0.171279 0.171279 0.171279 0.171279 3560.38 3560.38 2126.92 1.00
AIRLOOP F9 S2 DXAC HEAT PUMP 0.171829 0.171829 0.171829 0.171829 3568.40 3568.40 2126.92 1.00
AIRLOOP T SW DXAC HEAT PUMP 0.382080 0.382080 0.382080 0.382080 6798.46 6798.46 3713.56 1.00
AIRLOOP T NW DXAC HEAT PUMP 0.381499 0.381499 0.381499 0.381499 6785.88 6785.88 3724.56 1.00
AIRLOOP T SE DXAC HEAT PUMP 0.319003 0.319003 0.319003 0.319003 5913.18 5913.18 3713.56 1.00
AIRLOOP T NE DXAC HEAT PUMP 0.307674 0.307674 0.307674 0.307674 5693.60 5693.60 3724.56 1.00
AIRLOOP T N1 DXAC HEAT PUMP 0.229530 0.229530 0.229530 0.229530 4423.93 4423.93 2666.51 1.00
AIRLOOP T N2 DXAC HEAT PUMP 0.229513 0.229513 0.229513 0.229513 4423.44 4423.44 2666.51 1.00
AIRLOOP T S1 DXAC HEAT PUMP 0.248503 0.248503 0.248503 0.248503 4699.16 4699.16 2654.60 1.00
AIRLOOP T S2 DXAC HEAT PUMP 0.249019 0.249019 0.249019 0.249019 4706.44 4706.44 2654.60 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
AIRLOOP G SW SUPPLY FAN 0.252480
AIRLOOP G NW SUPPLY FAN 0.258263
AIRLOOP OFFICE SUPPLY FAN 0.344380
AIRLOOP G NE SUPPLY FAN 0.204253
AIRLOOP G N1 SUPPLY FAN 0.130073
AIRLOOP G N2 SUPPLY FAN 0.128983
AIRLOOP G S1 SUPPLY FAN 0.127901
AIRLOOP G S2 SUPPLY FAN 0.133629
AIRLOOP F2 SW SUPPLY FAN 0.296815
AIRLOOP F2 NW SUPPLY FAN 0.302203
AIRLOOP F2 SE SUPPLY FAN 0.269410
AIRLOOP F2 NE SUPPLY FAN 0.242948
AIRLOOP F2 N1 SUPPLY FAN 0.158633
AIRLOOP F2 N2 SUPPLY FAN 0.157773
AIRLOOP F2 S1 SUPPLY FAN 0.157276
AIRLOOP F2 S2 SUPPLY FAN 0.159245
AIRLOOP F3 SW SUPPLY FAN 0.297920
AIRLOOP F3 NW SUPPLY FAN 0.303478
AIRLOOP F3 SE SUPPLY FAN 0.251132
AIRLOOP F3 NE SUPPLY FAN 0.244751
AIRLOOP F3 N1 SUPPLY FAN 0.161255
AIRLOOP F3 N2 SUPPLY FAN 0.160404
AIRLOOP F3 S1 SUPPLY FAN 0.160212
AIRLOOP F3 S2 SUPPLY FAN 0.161002
AIRLOOP F4 SW SUPPLY FAN 0.299129
AIRLOOP F4 NW SUPPLY FAN 0.304622
AIRLOOP F4 SE SUPPLY FAN 0.250010
AIRLOOP F4 NE SUPPLY FAN 0.245512
AIRLOOP F4 N1 SUPPLY FAN 0.163045
AIRLOOP F4 N2 SUPPLY FAN 0.162201
AIRLOOP F4 S1 SUPPLY FAN 0.161945
AIRLOOP F4 S2 SUPPLY FAN 0.162552
AIRLOOP M SW SUPPLY FAN 0.302131
AIRLOOP M NW SUPPLY FAN 0.307643
AIRLOOP M SE SUPPLY FAN 0.252508
AIRLOOP M NE SUPPLY FAN 0.248227
AIRLOOP M N1 SUPPLY FAN 0.166486
AIRLOOP M N2 SUPPLY FAN 0.165647
AIRLOOP M S1 SUPPLY FAN 0.165257
AIRLOOP M S2 SUPPLY FAN 0.165833
AIRLOOP F6 SW SUPPLY FAN 0.299663
AIRLOOP F6 NW SUPPLY FAN 0.305044
AIRLOOP F6 SE SUPPLY FAN 0.249858
AIRLOOP F6 NE SUPPLY FAN 0.245461
AIRLOOP F6 N1 SUPPLY FAN 0.164469
AIRLOOP F6 N2 SUPPLY FAN 0.163640
AIRLOOP F6 S1 SUPPLY FAN 0.163275
AIRLOOP F6 S2 SUPPLY FAN 0.163843
AIRLOOP F7 SW SUPPLY FAN 0.299171
AIRLOOP F7 NW SUPPLY FAN 0.304497
AIRLOOP F7 SE SUPPLY FAN 0.249176
AIRLOOP F7 NE SUPPLY FAN 0.244741
AIRLOOP F7 N1 SUPPLY FAN 0.164358
AIRLOOP F7 N2 SUPPLY FAN 0.163536
AIRLOOP F7 S1 SUPPLY FAN 0.163118
AIRLOOP F7 S2 SUPPLY FAN 0.163680
AIRLOOP F8 SW SUPPLY FAN 0.300045
AIRLOOP F8 NW SUPPLY FAN 0.305335
AIRLOOP F8 SE SUPPLY FAN 0.249844
AIRLOOP F8 NE SUPPLY FAN 0.245353
AIRLOOP F8 N1 SUPPLY FAN 0.165582
AIRLOOP F8 N2 SUPPLY FAN 0.164767
AIRLOOP F8 S1 SUPPLY FAN 0.164225
AIRLOOP F8 S2 SUPPLY FAN 0.164784
AIRLOOP F9 SW SUPPLY FAN 0.310054
AIRLOOP F9 NW SUPPLY FAN 0.315567
AIRLOOP F9 SE SUPPLY FAN 0.254950
AIRLOOP F9 NE SUPPLY FAN 0.250119
AIRLOOP F9 N1 SUPPLY FAN 0.175239
AIRLOOP F9 N2 SUPPLY FAN 0.174424
AIRLOOP F9 S1 SUPPLY FAN 0.171279
AIRLOOP F9 S2 SUPPLY FAN 0.171829
AIRLOOP T SW SUPPLY FAN 0.382080
AIRLOOP T NW SUPPLY FAN 0.381499
AIRLOOP T SE SUPPLY FAN 0.319003
AIRLOOP T NE SUPPLY FAN 0.307674
AIRLOOP T N1 SUPPLY FAN 0.229530
AIRLOOP T N2 SUPPLY FAN 0.229513
AIRLOOP T S1 SUPPLY FAN 0.248503
AIRLOOP T S2 SUPPLY FAN 0.249019


COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Heating Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP HEATING MODE AIRLOOP G SW 0.252480 4608.67 0.000101
HEAT PUMP HEATING MODE AIRLOOP G NW 0.258263 4679.76 0.000102
HEAT PUMP HEATING MODE AIRLOOP OFFICE 0.344380 6206.62 0.000136
HEAT PUMP HEATING MODE AIRLOOP G NE 0.204253 3858.00 0.000084
HEAT PUMP HEATING MODE AIRLOOP G N1 0.130073 2735.61 0.000060
HEAT PUMP HEATING MODE AIRLOOP G N2 0.128983 2719.38 0.000059
HEAT PUMP HEATING MODE AIRLOOP G S1 0.127901 2760.70 0.000060
HEAT PUMP HEATING MODE AIRLOOP G S2 0.133629 2844.61 0.000062
HEAT PUMP HEATING MODE AIRLOOP F2 SW 0.296815 5325.85 0.000116
HEAT PUMP HEATING MODE AIRLOOP F2 NW 0.302203 5397.15 0.000118
HEAT PUMP HEATING MODE AIRLOOP F2 SE 0.269410 4908.14 0.000107
HEAT PUMP HEATING MODE AIRLOOP F2 NE 0.242948 4499.55 0.000098
HEAT PUMP HEATING MODE AIRLOOP F2 N1 0.158633 3205.84 0.000070
HEAT PUMP HEATING MODE AIRLOOP F2 N2 0.157773 3193.10 0.000070
HEAT PUMP HEATING MODE AIRLOOP F2 S1 0.157276 3237.26 0.000071
HEAT PUMP HEATING MODE AIRLOOP F2 S2 0.159245 3265.91 0.000071
HEAT PUMP HEATING MODE AIRLOOP F3 SW 0.297920 5394.79 0.000118
HEAT PUMP HEATING MODE AIRLOOP F3 NW 0.303478 5468.75 0.000119
HEAT PUMP HEATING MODE AIRLOOP F3 SE 0.251132 4696.98 0.000103
HEAT PUMP HEATING MODE AIRLOOP F3 NE 0.244751 4576.48 0.000100
HEAT PUMP HEATING MODE AIRLOOP F3 N1 0.161255 3272.61 0.000071
HEAT PUMP HEATING MODE AIRLOOP F3 N2 0.160404 3259.96 0.000071
HEAT PUMP HEATING MODE AIRLOOP F3 S1 0.160212 3308.04 0.000072
HEAT PUMP HEATING MODE AIRLOOP F3 S2 0.161002 3319.52 0.000073
HEAT PUMP HEATING MODE AIRLOOP F4 SW 0.299129 5451.62 0.000119
HEAT PUMP HEATING MODE AIRLOOP F4 NW 0.304622 5524.82 0.000121
HEAT PUMP HEATING MODE AIRLOOP F4 SE 0.250010 4718.56 0.000103
HEAT PUMP HEATING MODE AIRLOOP F4 NE 0.245512 4633.39 0.000101
HEAT PUMP HEATING MODE AIRLOOP F4 N1 0.163045 3320.05 0.000073
HEAT PUMP HEATING MODE AIRLOOP F4 N2 0.162201 3307.46 0.000072
HEAT PUMP HEATING MODE AIRLOOP F4 S1 0.161945 3354.28 0.000073
HEAT PUMP HEATING MODE AIRLOOP F4 S2 0.162552 3363.09 0.000073
HEAT PUMP HEATING MODE AIRLOOP M SW 0.302131 5526.84 0.000121
HEAT PUMP HEATING MODE AIRLOOP M NW 0.307643 5600.46 0.000122
HEAT PUMP HEATING MODE AIRLOOP M SE 0.252508 4785.39 0.000105
HEAT PUMP HEATING MODE AIRLOOP M NE 0.248227 4703.28 0.000103
HEAT PUMP HEATING MODE AIRLOOP M N1 0.166486 3387.85 0.000074
HEAT PUMP HEATING MODE AIRLOOP M N2 0.165647 3375.33 0.000074
HEAT PUMP HEATING MODE AIRLOOP M S1 0.165257 3419.96 0.000075
HEAT PUMP HEATING MODE AIRLOOP M S2 0.165833 3428.32 0.000075
HEAT PUMP HEATING MODE AIRLOOP F6 SW 0.299663 5523.95 0.000121
HEAT PUMP HEATING MODE AIRLOOP F6 NW 0.305044 5590.33 0.000122
HEAT PUMP HEATING MODE AIRLOOP F6 SE 0.249858 4772.72 0.000104
HEAT PUMP HEATING MODE AIRLOOP F6 NE 0.245461 4688.82 0.000102
HEAT PUMP HEATING MODE AIRLOOP F6 N1 0.164469 3372.72 0.000074
HEAT PUMP HEATING MODE AIRLOOP F6 N2 0.163640 3360.28 0.000073
HEAT PUMP HEATING MODE AIRLOOP F6 S1 0.163275 3405.06 0.000074
HEAT PUMP HEATING MODE AIRLOOP F6 S2 0.163843 3413.32 0.000075
HEAT PUMP HEATING MODE AIRLOOP F7 SW 0.299171 5540.59 0.000121
HEAT PUMP HEATING MODE AIRLOOP F7 NW 0.304497 5606.28 0.000122
HEAT PUMP HEATING MODE AIRLOOP F7 SE 0.249176 4785.33 0.000105
HEAT PUMP HEATING MODE AIRLOOP F7 NE 0.244741 4700.78 0.000103
HEAT PUMP HEATING MODE AIRLOOP F7 N1 0.164358 3383.77 0.000074
HEAT PUMP HEATING MODE AIRLOOP F7 N2 0.163536 3371.40 0.000074
HEAT PUMP HEATING MODE AIRLOOP F7 S1 0.163118 3415.24 0.000075
HEAT PUMP HEATING MODE AIRLOOP F7 S2 0.163680 3423.44 0.000075
HEAT PUMP HEATING MODE AIRLOOP F8 SW 0.300045 5574.45 0.000122
HEAT PUMP HEATING MODE AIRLOOP F8 NW 0.305335 5639.71 0.000123
HEAT PUMP HEATING MODE AIRLOOP F8 SE 0.249844 4815.18 0.000105
HEAT PUMP HEATING MODE AIRLOOP F8 NE 0.245353 4729.75 0.000103
HEAT PUMP HEATING MODE AIRLOOP F8 N1 0.165582 3413.26 0.000075
HEAT PUMP HEATING MODE AIRLOOP F8 N2 0.164767 3400.99 0.000074
HEAT PUMP HEATING MODE AIRLOOP F8 S1 0.164225 3442.85 0.000075
HEAT PUMP HEATING MODE AIRLOOP F8 S2 0.164784 3451.01 0.000075
HEAT PUMP HEATING MODE AIRLOOP F9 SW 0.310054 5733.40 0.000125
HEAT PUMP HEATING MODE AIRLOOP F9 NW 0.315567 5807.39 0.000127
HEAT PUMP HEATING MODE AIRLOOP F9 SE 0.254950 4908.53 0.000107
HEAT PUMP HEATING MODE AIRLOOP F9 NE 0.250119 4818.08 0.000105
HEAT PUMP HEATING MODE AIRLOOP F9 N1 0.175239 3567.04 0.000078
HEAT PUMP HEATING MODE AIRLOOP F9 N2 0.174424 3554.79 0.000078
HEAT PUMP HEATING MODE AIRLOOP F9 S1 0.171279 3560.38 0.000078
HEAT PUMP HEATING MODE AIRLOOP F9 S2 0.171829 3568.40 0.000078
HEAT PUMP HEATING MODE AIRLOOP T SW 0.382080 6798.46 0.000149
HEAT PUMP HEATING MODE AIRLOOP T NW 0.381499 6785.88 0.000148
HEAT PUMP HEATING MODE AIRLOOP T SE 0.319003 5913.18 0.000129
HEAT PUMP HEATING MODE AIRLOOP T NE 0.307674 5693.60 0.000124
HEAT PUMP HEATING MODE AIRLOOP T N1 0.229530 4423.93 0.000097
HEAT PUMP HEATING MODE AIRLOOP T N2 0.229513 4423.44 0.000097
HEAT PUMP HEATING MODE AIRLOOP T S1 0.248503 4699.16 0.000103
HEAT PUMP HEATING MODE AIRLOOP T S2 0.249019 4706.44 0.000103


Coil:Heating:Electric

Nominal Capacity [W]
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW 2729.40
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW 2722.15
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE 3402.45
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE 2722.15
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 1969.25
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 1969.25
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 1974.32
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 1980.66
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW 2721.67
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW 2714.59
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE 2740.79
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE 2714.59
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 1811.93
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 1811.93
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 1821.83
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 1823.15
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW 2745.26
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW 2741.58
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE 2747.49
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE 2741.58
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 1797.72
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 1797.72
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 1802.04
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 1802.26
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW 2802.27
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW 2801.60
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE 2802.52
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE 2801.60
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 1824.72
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 1824.72
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 1825.72
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 1825.75
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW 2837.60
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW 2838.34
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE 2837.63
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE 2838.34
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 1835.93
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 1835.93
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 1835.43
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 1835.43
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW 2926.03
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW 2929.62
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE 2926.04
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE 2929.62
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 1902.67
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 1902.67
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 1899.30
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 1899.30
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW 2989.08
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW 2994.24
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE 2989.08
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE 2994.24
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 1947.11
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 1947.11
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 1942.14
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 1942.14
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW 3053.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW 3060.05
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE 3053.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE 3060.05
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 1994.93
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 1994.93
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 1988.72
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 1988.72
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW 3215.62
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW 3221.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE 3215.62
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE 3221.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 2132.63
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 2132.63
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 2126.92
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 2126.92
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW 3713.56
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW 3724.56
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE 3713.56
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE 3724.56
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 2666.51
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 2666.51
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 2654.60
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 2654.60


PlantLoop

Maximum Loop Flow Rate [m3/s] Plant Loop Volume [m3]
SHWSYS1 0.000289 0.325214
SINGLE WATER PLANT LOOP 0.007568 8.51


Boiler:HotWater

Design Water Flow Rate [m3/s]
CENTRAL BOILER 0.007568


WaterHeater:Mixed

Use Side Design Flow Rate [m3/s]
SHWSYS1 WATER HEATER 0.000289


EvaporativeFluidCooler:SingleSpeed

Design Water Flow Rate [m3/s] Fan Power at Design Air Flow Rate [W] Design Air Flow Rate [m3/s] U-Factor Times Area Value at Design Air Flow Rate [W/C]
CENTRAL TOWER 0.007568 3653.19 9.65 11298.37


Pump:ConstantSpeed

Rated Flow Rate [m3/s] Rated Power Consumption [W]
SHWSYS1 PUMP 0.000289 36.93
PLANT CIRC PUMP 0.007568 2416.67



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:57

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW3 |
G WWALL SWA GWINDOW2 |
G NWALL NWA GWINDOW4 |
G WWALL NWA GWINDOW6 |
G SWALL SEA GWINDOW1 |
G EWALL SEA GWINDOW8 |
G NWALL NEA GWINDOW5 |
G EWALL NEA GWINDOW7 |
G NWALL N1A GWINDOW9 |
G NWALL N2A GWINDOW10 |
G SWALL S1A GWINDOW11 |
G SWALL S2A GWINDOW12 |
G WWALL C GWINDOW13 |
G EWALL C ENTRANCE DOOR |
F2 WWALL SWA F2WINDOW2 |
F2 SWALL SWA F2WINDOW3 |
F2 NWALL NWA F2WINDOW4 |
F2 WWALL NWA F2WINDOW6 |
F2 EWALL SEA F2WINDOW8 |
F2 SWALL SEA F2WINDOW1 |
F2 NWALL NEA F2WINDOW5 |
F2 EWALL NEA F2WINDOW7 |
F2 NWALL N1A F2WINDOW9 |
F2 NWALL N2A F2WINDOW10 |
F2 SWALL S1A F2WINDOW11 |
F2 SWALL S2A F2WINDOW12 |
F2 WWALL C F2WINDOW13 |
F2 EWALL C F2WINDOW14 |
F3 WWALL SWA F3WINDOW2 |
F3 SWALL SWA F3WINDOW3 |
F3 NWALL NWA F3WINDOW4 |
F3 WWALL NWA F3WINDOW6 |
F3 EWALL SEA F3WINDOW8 |
F3 SWALL SEA F3WINDOW1 |
F3 NWALL NEA F3WINDOW5 |
F3 EWALL NEA F3WINDOW7 |
F3 NWALL N1A F3WINDOW9 |
F3 NWALL N2A F3WINDOW10 |
F3 SWALL S1A F3WINDOW11 |
F3 SWALL S2A F3WINDOW12 |
F3 WWALL C F3WINDOW13 |
F3 EWALL C F3WINDOW14 |
F4 WWALL SWA F4WINDOW2 |
F4 SWALL SWA F4WINDOW3 |
F4 NWALL NWA F4WINDOW4 |
F4 WWALL NWA F4WINDOW6 |
F4 EWALL SEA F4WINDOW8 |
F4 SWALL SEA F4WINDOW1 |
F4 NWALL NEA F4WINDOW5 |
F4 EWALL NEA F4WINDOW7 |
F4 NWALL N1A F4WINDOW9 |
F4 NWALL N2A F4WINDOW10 |
F4 SWALL S1A F4WINDOW11 |
F4 SWALL S2A F4WINDOW12 |
F4 WWALL C F4WINDOW13 |
F4 EWALL C F4WINDOW14 |
M WWALL SWA MWINDOW2 |
M SWALL SWA MWINDOW3 |
M NWALL NWA MWINDOW4 |
M WWALL NWA MWINDOW6 |
M EWALL SEA MWINDOW8 |
M SWALL SEA MWINDOW1 |
M NWALL NEA MWINDOW5 |
M EWALL NEA MWINDOW7 |
M NWALL N1A MWINDOW9 |
M NWALL N2A MWINDOW10 |
M SWALL S1A MWINDOW11 |
M SWALL S2A MWINDOW12 |
M WWALL C MWINDOW13 |
M EWALL C MWINDOW14 |
F6 WWALL SWA F6WINDOW2 |
F6 SWALL SWA F6WINDOW3 |
F6 NWALL NWA F6WINDOW4 |
F6 WWALL NWA F6WINDOW6 |
F6 EWALL SEA F6WINDOW8 |
F6 SWALL SEA F6WINDOW1 |
F6 NWALL NEA F6WINDOW5 |
F6 EWALL NEA F6WINDOW7 |
F6 NWALL N1A F6WINDOW9 |
F6 NWALL N2A F6WINDOW10 |
F6 SWALL S1A F6WINDOW11 |
F6 SWALL S2A F6WINDOW12 |
F6 WWALL C F6WINDOW13 |
F6 EWALL C F6WINDOW14 |
F7 WWALL SWA F7WINDOW2 |
F7 SWALL SWA F7WINDOW3 |
F7 NWALL NWA F7WINDOW4 |
F7 WWALL NWA F7WINDOW6 |
F7 EWALL SEA F7WINDOW8 |
F7 SWALL SEA F7WINDOW1 |
F7 NWALL NEA F7WINDOW5 |
F7 EWALL NEA F7WINDOW7 |
F7 NWALL N1A F7WINDOW9 |
F7 NWALL N2A F7WINDOW10 |
F7 SWALL S1A F7WINDOW11 |
F7 SWALL S2A F7WINDOW12 |
F7 WWALL C F7WINDOW13 |
F7 EWALL C F7WINDOW14 |
F8 WWALL SWA F8WINDOW2 |
F8 SWALL SWA F8WINDOW3 |
F8 NWALL NWA F8WINDOW4 |
F8 WWALL NWA F8WINDOW6 |
F8 EWALL SEA F8WINDOW8 |
F8 SWALL SEA F8WINDOW1 |
F8 NWALL NEA F8WINDOW5 |
F8 EWALL NEA F8WINDOW7 |
F8 NWALL N1A F8WINDOW9 |
F8 NWALL N2A F8WINDOW10 |
F8 SWALL S1A F8WINDOW11 |
F8 SWALL S2A F8WINDOW12 |
F8 WWALL C F8WINDOW13 |
F8 EWALL C F8WINDOW14 |
F9 WWALL SWA F9WINDOW2 |
F9 SWALL SWA F9WINDOW3 |
F9 NWALL NWA F9WINDOW4 |
F9 WWALL NWA F9WINDOW6 |
F9 EWALL SEA F9WINDOW8 |
F9 SWALL SEA F9WINDOW1 |
F9 NWALL NEA F9WINDOW5 |
F9 EWALL NEA F9WINDOW7 |
F9 NWALL N1A F9WINDOW9 |
F9 NWALL N2A F9WINDOW10 |
F9 SWALL S1A F9WINDOW11 |
F9 SWALL S2A F9WINDOW12 |
F9 WWALL C F9WINDOW13 |
F9 EWALL C F9WINDOW14 |
T WWALL SWA TWINDOW2 |
T SWALL SWA TWINDOW3 |
T NWALL NWA TWINDOW4 |
T WWALL NWA TWINDOW6 |
T EWALL SEA TWINDOW8 |
T SWALL SEA TWINDOW1 |
T NWALL NEA TWINDOW5 |
T EWALL NEA TWINDOW7 |
T NWALL N1A TWINDOW9 |
T NWALL N2A TWINDOW10 |
T SWALL S1A TWINDOW11 |
T SWALL S2A TWINDOW12 |
T WWALL C TWINDOW13 |
T EWALL C TWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2015-09-09 19:11:57

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.37 10.50
February 22.71 12.77
March 23.10 16.20
April 23.77 20.49
May 24.25 24.03
June 24.39 27.02
July 24.40 28.27
August 24.40 28.21
September 24.37 26.44
October 23.92 20.33
November 23.51 17.10
December 22.71 12.54
     
Annual Sum or Average 23.66 20.36
Minimum of Months 22.37 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.98 10.50
February 22.44 12.77
March 22.91 16.20
April 23.74 20.49
May 24.27 24.03
June 24.39 27.02
July 24.40 28.27
August 24.40 28.21
September 24.36 26.44
October 23.78 20.33
November 23.16 17.10
December 22.30 12.54
     
Annual Sum or Average 23.52 20.36
Minimum of Months 21.98 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.74 10.50
February 23.12 12.77
March 23.57 16.20
April 24.12 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.40 26.44
October 24.13 20.33
November 23.77 17.10
December 23.03 12.54
     
Annual Sum or Average 23.87 20.36
Minimum of Months 22.74 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.91 10.50
February 22.36 12.77
March 22.84 16.20
April 23.71 20.49
May 24.26 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.37 26.44
October 23.76 20.33
November 23.11 17.10
December 22.22 12.54
     
Annual Sum or Average 23.48 20.36
Minimum of Months 21.91 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.90 10.50
February 22.30 12.77
March 22.74 16.20
April 23.62 20.49
May 24.22 24.03
June 24.39 27.02
July 24.40 28.27
August 24.40 28.21
September 24.36 26.44
October 23.69 20.33
November 23.03 17.10
December 22.19 12.54
     
Annual Sum or Average 23.44 20.36
Minimum of Months 21.90 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.89 10.50
February 22.30 12.77
March 22.73 16.20
April 23.61 20.49
May 24.22 24.03
June 24.39 27.02
July 24.40 28.27
August 24.40 28.21
September 24.36 26.44
October 23.68 20.33
November 23.03 17.10
December 22.19 12.54
     
Annual Sum or Average 23.44 20.36
Minimum of Months 21.89 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.37 10.50
February 22.66 12.77
March 23.03 16.20
April 23.70 20.49
May 24.22 24.03
June 24.39 27.02
July 24.41 28.27
August 24.46 28.21
September 24.44 26.44
October 23.92 20.33
November 23.51 17.10
December 22.71 12.54
     
Annual Sum or Average 23.66 20.36
Minimum of Months 22.37 10.50
Maximum of Months 24.46 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.41 10.50
February 22.69 12.77
March 23.08 16.20
April 23.74 20.49
May 24.23 24.03
June 24.39 27.02
July 24.40 28.27
August 24.45 28.21
September 24.43 26.44
October 23.94 20.33
November 23.55 17.10
December 22.74 12.54
     
Annual Sum or Average 23.68 20.36
Minimum of Months 22.41 10.50
Maximum of Months 24.45 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 19.10 10.50
February 20.06 12.77
March 21.50 16.20
April 23.31 20.49
May 24.83 24.03
June 26.52 27.02
July 27.04 28.27
August 27.03 28.21
September 26.48 26.44
October 23.68 20.33
November 22.08 17.10
December 19.99 12.54
     
Annual Sum or Average 23.48 20.36
Minimum of Months 19.10 10.50
Maximum of Months 27.04 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SW APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.70 10.50
February 23.07 12.77
March 23.53 16.20
April 24.10 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.22 20.33
November 23.92 17.10
December 23.14 12.54
     
Annual Sum or Average 23.89 20.36
Minimum of Months 22.70 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NW APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.15 10.50
February 22.71 12.77
March 23.26 16.20
April 24.06 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.08 20.33
November 23.52 17.10
December 22.54 12.54
     
Annual Sum or Average 23.69 20.36
Minimum of Months 22.15 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SE APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.76 10.50
February 23.12 12.77
March 23.62 16.20
April 24.16 20.49
May 24.37 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.39 26.44
October 24.26 20.33
November 23.96 17.10
December 23.19 12.54
     
Annual Sum or Average 23.92 20.36
Minimum of Months 22.76 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NE APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.05 10.50
February 22.62 12.77
March 23.19 16.20
April 24.03 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.07 20.33
November 23.46 17.10
December 22.42 12.54
     
Annual Sum or Average 23.65 20.36
Minimum of Months 22.05 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N1 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.10 10.50
February 22.62 12.77
March 23.17 16.20
April 24.01 20.49
May 24.35 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.04 20.33
November 23.47 17.10
December 22.48 12.54
     
Annual Sum or Average 23.66 20.36
Minimum of Months 22.10 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N2 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.10 10.50
February 22.61 12.77
March 23.17 16.20
April 24.01 20.49
May 24.35 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.04 20.33
November 23.47 17.10
December 22.47 12.54
     
Annual Sum or Average 23.65 20.36
Minimum of Months 22.10 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S1 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.82 10.50
February 23.10 12.77
March 23.55 16.20
April 24.08 20.49
May 24.35 24.03
June 24.39 27.02
July 24.40 28.27
August 24.44 28.21
September 24.44 26.44
October 24.26 20.33
November 24.01 17.10
December 23.24 12.54
     
Annual Sum or Average 23.93 20.36
Minimum of Months 22.82 10.50
Maximum of Months 24.44 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S2 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.83 10.50
February 23.11 12.77
March 23.57 16.20
April 24.09 20.49
May 24.35 24.03
June 24.40 27.02
July 24.40 28.27
August 24.44 28.21
September 24.43 26.44
October 24.26 20.33
November 24.01 17.10
December 23.26 12.54
     
Annual Sum or Average 23.93 20.36
Minimum of Months 22.83 10.50
Maximum of Months 24.44 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 CORRIDOR

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.80 10.50
February 23.41 12.77
March 24.30 16.20
April 25.31 20.49
May 26.00 24.03
June 26.49 27.02
July 26.65 28.27
August 26.63 28.21
September 26.47 26.44
October 25.54 20.33
November 24.76 17.10
December 23.39 12.54
     
Annual Sum or Average 25.15 20.36
Minimum of Months 22.80 10.50
Maximum of Months 26.65 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SW APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.73 10.50
February 23.11 12.77
March 23.57 16.20
April 24.14 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.25 20.33
November 23.97 17.10
December 23.21 12.54
     
Annual Sum or Average 23.91 20.36
Minimum of Months 22.73 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NW APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.18 10.50
February 22.76 12.77
March 23.31 16.20
April 24.09 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.12 20.33
November 23.57 17.10
December 22.58 12.54
     
Annual Sum or Average 23.72 20.36
Minimum of Months 22.18 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SE APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.67 10.50
February 23.06 12.77
March 23.55 16.20
April 24.14 20.49
May 24.37 24.03
June 24.40 27.02
July 24.40 28.27
August 24.41 28.21
September 24.39 26.44
October 24.26 20.33
November 23.94 17.10
December 23.15 12.54
     
Annual Sum or Average 23.90 20.36
Minimum of Months 22.67 10.50
Maximum of Months 24.41 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NE APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.08 10.50
February 22.67 12.77
March 23.24 16.20
April 24.08 20.49
May 24.37 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.11 20.33
November 23.52 17.10
December 22.46 12.54
     
Annual Sum or Average 23.68 20.36
Minimum of Months 22.08 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N1 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.16 10.50
February 22.70 12.77
March 23.27 16.20
April 24.08 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.10 20.33
November 23.57 17.10
December 22.57 12.54
     
Annual Sum or Average 23.70 20.36
Minimum of Months 22.16 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N2 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.16 10.50
February 22.70 12.77
March 23.26 16.20
April 24.08 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.10 20.33
November 23.56 17.10
December 22.56 12.54
     
Annual Sum or Average 23.70 20.36
Minimum of Months 22.16 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S1 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.92 10.50
February 23.18 12.77
March 23.64 16.20
April 24.14 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.44 28.21
September 24.44 26.44
October 24.30 20.33
November 24.08 17.10
December 23.37 12.54
     
Annual Sum or Average 23.98 20.36
Minimum of Months 22.92 10.50
Maximum of Months 24.44 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S2 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.92 10.50
February 23.18 12.77
March 23.65 16.20
April 24.14 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.44 28.21
September 24.44 26.44
October 24.30 20.33
November 24.08 17.10
December 23.37 12.54
     
Annual Sum or Average 23.98 20.36
Minimum of Months 22.92 10.50
Maximum of Months 24.44 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 CORRIDOR

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.17 10.50
February 23.79 12.77
March 24.64 16.20
April 25.61 20.49
May 26.23 24.03
June 26.55 27.02
July 26.67 28.27
August 26.65 28.21
September 26.51 26.44
October 25.82 20.33
November 25.11 17.10
December 23.78 12.54
     
Annual Sum or Average 25.38 20.36
Minimum of Months 23.17 10.50
Maximum of Months 26.67 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SW APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.74 10.50
February 23.13 12.77
March 23.54 16.20
April 24.13 20.49
May 24.37 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.25 20.33
November 23.96 17.10
December 23.20 12.54
     
Annual Sum or Average 23.91 20.36
Minimum of Months 22.74 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NW APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.20 10.50
February 22.79 12.77
March 23.29 16.20
April 24.09 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.13 20.33
November 23.57 17.10
December 22.58 12.54
     
Annual Sum or Average 23.72 20.36
Minimum of Months 22.20 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SE APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.65 10.50
February 23.05 12.77
March 23.51 16.20
April 24.12 20.49
May 24.37 24.03
June 24.40 27.02
July 24.40 28.27
August 24.41 28.21
September 24.40 26.44
October 24.25 20.33
November 23.92 17.10
December 23.12 12.54
     
Annual Sum or Average 23.89 20.36
Minimum of Months 22.65 10.50
Maximum of Months 24.41 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NE APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.09 10.50
February 22.70 12.77
March 23.22 16.20
April 24.07 20.49
May 24.37 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.12 20.33
November 23.52 17.10
December 22.45 12.54
     
Annual Sum or Average 23.68 20.36
Minimum of Months 22.09 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N1 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.20 10.50
February 22.75 12.77
March 23.28 16.20
April 24.08 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.12 20.33
November 23.59 17.10
December 22.59 12.54
     
Annual Sum or Average 23.72 20.36
Minimum of Months 22.20 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N2 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.19 10.50
February 22.75 12.77
March 23.28 16.20
April 24.08 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.12 20.33
November 23.58 17.10
December 22.58 12.54
     
Annual Sum or Average 23.71 20.36
Minimum of Months 22.19 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S1 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.96 10.50
February 23.21 12.77
March 23.64 16.20
April 24.14 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.44 28.21
September 24.44 26.44
October 24.31 20.33
November 24.09 17.10
December 23.38 12.54
     
Annual Sum or Average 23.98 20.36
Minimum of Months 22.96 10.50
Maximum of Months 24.44 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S2 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.96 10.50
February 23.21 12.77
March 23.64 16.20
April 24.14 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.44 28.21
September 24.44 26.44
October 24.31 20.33
November 24.09 17.10
December 23.38 12.54
     
Annual Sum or Average 23.98 20.36
Minimum of Months 22.96 10.50
Maximum of Months 24.44 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 CORRIDOR

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.30 10.50
February 23.92 12.77
March 24.75 16.20
April 25.73 20.49
May 26.33 24.03
June 26.63 27.02
July 26.74 28.27
August 26.72 28.21
September 26.59 26.44
October 25.94 20.33
November 25.23 17.10
December 23.91 12.54
     
Annual Sum or Average 25.49 20.36
Minimum of Months 23.30 10.50
Maximum of Months 26.74 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.71 10.50
February 23.11 12.77
March 23.51 16.20
April 24.11 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.25 20.33
November 23.95 17.10
December 23.18 12.54
     
Annual Sum or Average 23.90 20.36
Minimum of Months 22.71 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.19 10.50
February 22.78 12.77
March 23.27 16.20
April 24.07 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.13 20.33
November 23.57 17.10
December 22.57 12.54
     
Annual Sum or Average 23.71 20.36
Minimum of Months 22.19 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.62 10.50
February 23.03 12.77
March 23.47 16.20
April 24.10 20.49
May 24.37 24.03
June 24.40 27.02
July 24.40 28.27
August 24.41 28.21
September 24.40 26.44
October 24.25 20.33
November 23.91 17.10
December 23.09 12.54
     
Annual Sum or Average 23.87 20.36
Minimum of Months 22.62 10.50
Maximum of Months 24.41 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.08 10.50
February 22.69 12.77
March 23.20 16.20
April 24.05 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.12 20.33
November 23.51 17.10
December 22.45 12.54
     
Annual Sum or Average 23.67 20.36
Minimum of Months 22.08 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.20 10.50
February 22.76 12.77
March 23.27 16.20
April 24.08 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.12 20.33
November 23.59 17.10
December 22.59 12.54
     
Annual Sum or Average 23.72 20.36
Minimum of Months 22.20 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.20 10.50
February 22.75 12.77
March 23.27 16.20
April 24.08 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.12 20.33
November 23.59 17.10
December 22.58 12.54
     
Annual Sum or Average 23.71 20.36
Minimum of Months 22.20 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.95 10.50
February 23.20 12.77
March 23.62 16.20
April 24.13 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.44 28.21
September 24.43 26.44
October 24.31 20.33
November 24.09 17.10
December 23.38 12.54
     
Annual Sum or Average 23.98 20.36
Minimum of Months 22.95 10.50
Maximum of Months 24.44 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.95 10.50
February 23.20 12.77
March 23.62 16.20
April 24.13 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.43 28.21
September 24.43 26.44
October 24.31 20.33
November 24.08 17.10
December 23.37 12.54
     
Annual Sum or Average 23.98 20.36
Minimum of Months 22.95 10.50
Maximum of Months 24.43 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.85 10.50
February 24.47 12.77
March 25.27 16.20
April 26.25 20.49
May 26.86 24.03
June 27.15 27.02
July 27.26 28.27
August 27.24 28.21
September 27.11 26.44
October 26.48 20.33
November 25.77 17.10
December 24.45 12.54
     
Annual Sum or Average 26.02 20.36
Minimum of Months 23.85 10.50
Maximum of Months 27.26 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SW APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.61 10.50
February 23.04 12.77
March 23.42 16.20
April 24.07 20.49
May 24.36 24.03
June 24.39 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.23 20.33
November 23.90 17.10
December 23.10 12.54
     
Annual Sum or Average 23.86 20.36
Minimum of Months 22.61 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NW APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.13 10.50
February 22.72 12.77
March 23.19 16.20
April 24.03 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.09 20.33
November 23.51 17.10
December 22.49 12.54
     
Annual Sum or Average 23.68 20.36
Minimum of Months 22.13 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SE APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.52 10.50
February 22.96 12.77
March 23.38 16.20
April 24.05 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.41 28.21
September 24.40 26.44
October 24.23 20.33
November 23.86 17.10
December 23.00 12.54
     
Annual Sum or Average 23.83 20.36
Minimum of Months 22.52 10.50
Maximum of Months 24.41 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NE APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.03 10.50
February 22.64 12.77
March 23.11 16.20
April 24.00 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.08 20.33
November 23.46 17.10
December 22.38 12.54
     
Annual Sum or Average 23.64 20.36
Minimum of Months 22.03 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N1 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.15 10.50
February 22.70 12.77
March 23.19 16.20
April 24.03 20.49
May 24.35 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.09 20.33
November 23.53 17.10
December 22.52 12.54
     
Annual Sum or Average 23.68 20.36
Minimum of Months 22.15 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N2 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.14 10.50
February 22.70 12.77
March 23.18 16.20
April 24.03 20.49
May 24.35 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.08 20.33
November 23.53 17.10
December 22.51 12.54
     
Annual Sum or Average 23.68 20.36
Minimum of Months 22.14 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S1 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.85 10.50
February 23.13 12.77
March 23.53 16.20
April 24.09 20.49
May 24.35 24.03
June 24.40 27.02
July 24.40 28.27
August 24.43 28.21
September 24.43 26.44
October 24.29 20.33
November 24.04 17.10
December 23.29 12.54
     
Annual Sum or Average 23.94 20.36
Minimum of Months 22.85 10.50
Maximum of Months 24.43 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S2 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.84 10.50
February 23.13 12.77
March 23.53 16.20
April 24.09 20.49
May 24.35 24.03
June 24.40 27.02
July 24.40 28.27
August 24.43 28.21
September 24.43 26.44
October 24.28 20.33
November 24.04 17.10
December 23.29 12.54
     
Annual Sum or Average 23.94 20.36
Minimum of Months 22.84 10.50
Maximum of Months 24.43 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 CORRIDOR

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.20 10.50
February 23.84 12.77
March 24.63 16.20
April 25.66 20.49
May 26.31 24.03
June 26.61 27.02
July 26.73 28.27
August 26.71 28.21
September 26.57 26.44
October 25.90 20.33
November 25.17 17.10
December 23.81 12.54
     
Annual Sum or Average 25.44 20.36
Minimum of Months 23.20 10.50
Maximum of Months 26.73 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SW APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.54 10.50
February 22.99 12.77
March 23.36 16.20
April 24.04 20.49
May 24.35 24.03
June 24.39 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.22 20.33
November 23.87 17.10
December 23.04 12.54
     
Annual Sum or Average 23.83 20.36
Minimum of Months 22.54 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NW APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.09 10.50
February 22.68 12.77
March 23.13 16.20
April 24.00 20.49
May 24.35 24.03
June 24.39 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.07 20.33
November 23.47 17.10
December 22.45 12.54
     
Annual Sum or Average 23.65 20.36
Minimum of Months 22.09 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SE APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.45 10.50
February 22.91 12.77
March 23.31 16.20
April 24.02 20.49
May 24.36 24.03
June 24.40 27.02
July 24.40 28.27
August 24.41 28.21
September 24.39 26.44
October 24.21 20.33
November 23.82 17.10
December 22.94 12.54
     
Annual Sum or Average 23.80 20.36
Minimum of Months 22.45 10.50
Maximum of Months 24.41 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NE APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.00 10.50
February 22.60 12.77
March 23.05 16.20
April 23.97 20.49
May 24.35 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.06 20.33
November 23.42 17.10
December 22.35 12.54
     
Annual Sum or Average 23.62 20.36
Minimum of Months 22.00 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N1 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.10 10.50
February 22.66 12.77
March 23.13 16.20
April 24.00 20.49
May 24.34 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.06 20.33
November 23.49 17.10
December 22.48 12.54
     
Annual Sum or Average 23.66 20.36
Minimum of Months 22.10 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N2 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.10 10.50
February 22.66 12.77
March 23.12 16.20
April 24.00 20.49
May 24.34 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.06 20.33
November 23.49 17.10
December 22.47 12.54
     
Annual Sum or Average 23.65 20.36
Minimum of Months 22.10 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S1 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.76 10.50
February 23.08 12.77
March 23.46 16.20
April 24.06 20.49
May 24.35 24.03
June 24.40 27.02
July 24.40 28.27
August 24.43 28.21
September 24.43 26.44
October 24.27 20.33
November 24.00 17.10
December 23.23 12.54
     
Annual Sum or Average 23.91 20.36
Minimum of Months 22.76 10.50
Maximum of Months 24.43 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S2 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.76 10.50
February 23.07 12.77
March 23.46 16.20
April 24.06 20.49
May 24.35 24.03
June 24.40 27.02
July 24.40 28.27
August 24.43 28.21
September 24.43 26.44
October 24.27 20.33
November 24.00 17.10
December 23.22 12.54
     
Annual Sum or Average 23.91 20.36
Minimum of Months 22.76 10.50
Maximum of Months 24.43 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 CORRIDOR

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.03 10.50
February 23.68 12.77
March 24.47 16.20
April 25.53 20.49
May 26.23 24.03
June 26.54 27.02
July 26.66 28.27
August 26.64 28.21
September 26.50 26.44
October 25.80 20.33
November 25.04 17.10
December 23.65 12.54
     
Annual Sum or Average 25.32 20.36
Minimum of Months 23.03 10.50
Maximum of Months 26.66 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SW APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.48 10.50
February 22.95 12.77
March 23.30 16.20
April 24.01 20.49
May 24.35 24.03
June 24.39 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.20 20.33
November 23.83 17.10
December 22.98 12.54
     
Annual Sum or Average 23.81 20.36
Minimum of Months 22.48 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NW APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.06 10.50
February 22.65 12.77
March 23.08 16.20
April 23.97 20.49
May 24.35 24.03
June 24.39 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.05 20.33
November 23.44 17.10
December 22.41 12.54
     
Annual Sum or Average 23.63 20.36
Minimum of Months 22.06 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SE APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.40 10.50
February 22.86 12.77
March 23.25 16.20
April 23.99 20.49
May 24.35 24.03
June 24.39 27.02
July 24.40 28.27
August 24.41 28.21
September 24.39 26.44
October 24.19 20.33
November 23.79 17.10
December 22.88 12.54
     
Annual Sum or Average 23.78 20.36
Minimum of Months 22.40 10.50
Maximum of Months 24.41 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NE APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.98 10.50
February 22.57 12.77
March 23.01 16.20
April 23.94 20.49
May 24.35 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.04 20.33
November 23.39 17.10
December 22.32 12.54
     
Annual Sum or Average 23.60 20.36
Minimum of Months 21.98 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N1 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.08 10.50
February 22.63 12.77
March 23.08 16.20
April 23.97 20.49
May 24.34 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.04 20.33
November 23.46 17.10
December 22.44 12.54
     
Annual Sum or Average 23.64 20.36
Minimum of Months 22.08 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N2 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.07 10.50
February 22.63 12.77
March 23.08 16.20
April 23.97 20.49
May 24.34 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.04 20.33
November 23.45 17.10
December 22.43 12.54
     
Annual Sum or Average 23.64 20.36
Minimum of Months 22.07 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S1 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.69 10.50
February 23.03 12.77
March 23.40 16.20
April 24.03 20.49
May 24.35 24.03
June 24.40 27.02
July 24.40 28.27
August 24.43 28.21
September 24.43 26.44
October 24.26 20.33
November 23.97 17.10
December 23.17 12.54
     
Annual Sum or Average 23.88 20.36
Minimum of Months 22.69 10.50
Maximum of Months 24.43 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S2 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.69 10.50
February 23.03 12.77
March 23.40 16.20
April 24.03 20.49
May 24.35 24.03
June 24.40 27.02
July 24.40 28.27
August 24.43 28.21
September 24.43 26.44
October 24.25 20.33
November 23.97 17.10
December 23.16 12.54
     
Annual Sum or Average 23.88 20.36
Minimum of Months 22.69 10.50
Maximum of Months 24.43 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 CORRIDOR

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.94 10.50
February 23.60 12.77
March 24.40 16.20
April 25.49 20.49
May 26.23 24.03
June 26.55 27.02
July 26.67 28.27
August 26.65 28.21
September 26.50 26.44
October 25.76 20.33
November 24.98 17.10
December 23.57 12.54
     
Annual Sum or Average 25.29 20.36
Minimum of Months 22.94 10.50
Maximum of Months 26.67 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SW APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.43 10.50
February 22.91 12.77
March 23.25 16.20
April 23.99 20.49
May 24.35 24.03
June 24.39 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.18 20.33
November 23.80 17.10
December 22.93 12.54
     
Annual Sum or Average 23.79 20.36
Minimum of Months 22.43 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NW APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.04 10.50
February 22.63 12.77
March 23.05 16.20
April 23.95 20.49
May 24.34 24.03
June 24.39 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.03 20.33
November 23.42 17.10
December 22.39 12.54
     
Annual Sum or Average 23.62 20.36
Minimum of Months 22.04 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SE APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.35 10.50
February 22.82 12.77
March 23.20 16.20
April 23.96 20.49
May 24.35 24.03
June 24.39 27.02
July 24.40 28.27
August 24.41 28.21
September 24.39 26.44
October 24.17 20.33
November 23.75 17.10
December 22.82 12.54
     
Annual Sum or Average 23.76 20.36
Minimum of Months 22.35 10.50
Maximum of Months 24.41 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NE APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.96 10.50
February 22.55 12.77
March 22.97 16.20
April 23.91 20.49
May 24.34 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.02 20.33
November 23.36 17.10
December 22.30 12.54
     
Annual Sum or Average 23.59 20.36
Minimum of Months 21.96 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N1 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.06 10.50
February 22.62 12.77
March 23.05 16.20
April 23.95 20.49
May 24.34 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.02 20.33
November 23.43 17.10
December 22.41 12.54
     
Annual Sum or Average 23.63 20.36
Minimum of Months 22.06 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N2 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.05 10.50
February 22.61 12.77
March 23.04 16.20
April 23.95 20.49
May 24.34 24.03
June 24.40 27.02
July 24.40 28.27
August 24.40 28.21
September 24.38 26.44
October 24.02 20.33
November 23.42 17.10
December 22.40 12.54
     
Annual Sum or Average 23.62 20.36
Minimum of Months 22.05 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S1 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.62 10.50
February 22.99 12.77
March 23.34 16.20
April 24.01 20.49
May 24.34 24.03
June 24.40 27.02
July 24.40 28.27
August 24.43 28.21
September 24.42 26.44
October 24.23 20.33
November 23.92 17.10
December 23.10 12.54
     
Annual Sum or Average 23.85 20.36
Minimum of Months 22.62 10.50
Maximum of Months 24.43 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S2 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.62 10.50
February 22.98 12.77
March 23.34 16.20
April 24.00 20.49
May 24.34 24.03
June 24.40 27.02
July 24.40 28.27
August 24.43 28.21
September 24.42 26.44
October 24.23 20.33
November 23.92 17.10
December 23.09 12.54
     
Annual Sum or Average 23.85 20.36
Minimum of Months 22.62 10.50
Maximum of Months 24.43 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 CORRIDOR

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.84 10.50
February 23.53 12.77
March 24.35 16.20
April 25.51 20.49
May 26.30 24.03
June 26.66 27.02
July 26.80 28.27
August 26.77 28.21
September 26.58 26.44
October 25.76 20.33
November 24.92 17.10
December 23.47 12.54
     
Annual Sum or Average 25.30 20.36
Minimum of Months 22.84 10.50
Maximum of Months 26.80 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.43 10.50
February 22.85 12.77
March 23.14 16.20
April 23.88 20.49
May 24.31 24.03
June 24.39 27.02
July 24.40 28.27
August 24.40 28.21
September 24.36 26.44
October 24.01 20.33
November 23.61 17.10
December 22.81 12.54
     
Annual Sum or Average 23.72 20.36
Minimum of Months 22.43 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.09 10.50
February 22.62 12.77
March 23.00 16.20
April 23.85 20.49
May 24.31 24.03
June 24.39 27.02
July 24.40 28.27
August 24.40 28.21
September 24.36 26.44
October 23.88 20.33
November 23.32 17.10
December 22.42 12.54
     
Annual Sum or Average 23.59 20.36
Minimum of Months 22.09 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.36 10.50
February 22.77 12.77
March 23.10 16.20
April 23.85 20.49
May 24.31 24.03
June 24.39 27.02
July 24.40 28.27
August 24.41 28.21
September 24.37 26.44
October 23.99 20.33
November 23.56 17.10
December 22.73 12.54
     
Annual Sum or Average 23.69 20.36
Minimum of Months 22.36 10.50
Maximum of Months 24.41 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.99 10.50
February 22.53 12.77
March 22.94 16.20
April 23.81 20.49
May 24.30 24.03
June 24.39 27.02
July 24.40 28.27
August 24.40 28.21
September 24.36 26.44
October 23.86 20.33
November 23.27 17.10
December 22.32 12.54
     
Annual Sum or Average 23.55 20.36
Minimum of Months 21.99 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.08 10.50
February 22.60 12.77
March 22.99 16.20
April 23.85 20.49
May 24.30 24.03
June 24.39 27.02
July 24.40 28.27
August 24.40 28.21
September 24.36 26.44
October 23.87 20.33
November 23.31 17.10
December 22.39 12.54
     
Annual Sum or Average 23.58 20.36
Minimum of Months 22.08 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.07 10.50
February 22.59 12.77
March 22.99 16.20
April 23.85 20.49
May 24.30 24.03
June 24.39 27.02
July 24.40 28.27
August 24.40 28.21
September 24.36 26.44
October 23.87 20.33
November 23.31 17.10
December 22.38 12.54
     
Annual Sum or Average 23.58 20.36
Minimum of Months 22.07 10.50
Maximum of Months 24.40 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.57 10.50
February 22.93 12.77
March 23.21 16.20
April 23.91 20.49
May 24.31 24.03
June 24.39 27.02
July 24.40 28.27
August 24.41 28.21
September 24.37 26.44
October 24.05 20.33
November 23.71 17.10
December 22.93 12.54
     
Annual Sum or Average 23.77 20.36
Minimum of Months 22.57 10.50
Maximum of Months 24.41 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.57 10.50
February 22.93 12.77
March 23.21 16.20
April 23.91 20.49
May 24.31 24.03
June 24.39 27.02
July 24.40 28.27
August 24.41 28.21
September 24.37 26.44
October 24.05 20.33
November 23.70 17.10
December 22.93 12.54
     
Annual Sum or Average 23.77 20.36
Minimum of Months 22.57 10.50
Maximum of Months 24.41 28.27



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2015-09-09 19:11:57

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.11 10.50
February 23.89 12.77
March 24.81 16.20
April 26.16 20.49
May 27.10 24.03
June 27.60 27.02
July 27.78 28.27
August 27.74 28.21
September 27.41 26.44
October 26.29 20.33
November 25.30 17.10
December 23.75 12.54
     
Annual Sum or Average 25.92 20.36
Minimum of Months 23.11 10.50
Maximum of Months 27.78 28.27



Table of Contents

Report: COMPONENTS OF PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2015-09-09 19:11:57

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY {AT MAX/MIN} [W] HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W]
January 0.223190E+12 130650.694 18-JAN-20:00 14401.373 49889.926 20924.025 30976.465 0.000 10364.000 2453.601 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
February 0.205752E+12 140372.331 28-FEB-17:15 11327.174 57142.088 20924.025 0.000 44388.762 0.000 2453.601 2141.485 0.000 0.000 0.000 0.000 0.000 0.000 0.000
March 0.228462E+12 165742.896 26-MAR-16:15 11327.174 57042.023 20924.025 0.000 69041.782 0.000 2453.601 2966.649 0.000 0.000 0.000 0.000 0.000 0.000 0.000
April 0.253760E+12 179535.504 30-APR-18:00 14401.373 51749.961 20924.025 0.000 74427.154 10364.000 2453.601 3454.365 0.000 0.000 0.000 0.000 0.000 0.000 0.000
May 0.312297E+12 177655.633 23-MAY-17:30 13120.457 57042.023 20924.025 0.000 78637.183 0.000 2453.601 3490.335 0.000 0.000 0.000 0.000 0.000 0.000 0.000
June 0.347134E+12 184680.531 25-JUN-17:15 13120.457 57042.023 20924.025 0.000 85499.424 0.000 2453.601 3653.190 0.000 0.000 0.000 0.000 0.000 0.000 0.000
July 0.371650E+12 187111.801 12-JUL-17:15 13120.457 57042.023 20924.025 0.000 87930.694 0.000 2453.601 3653.190 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 0.370077E+12 189408.373 04-AUG-17:15 13120.457 57042.023 20924.025 0.000 90227.266 0.000 2453.601 3653.190 0.000 0.000 0.000 0.000 0.000 0.000 0.000
September 0.338641E+12 182155.607 20-SEP-16:15 11327.174 57142.088 20924.025 0.000 84660.333 0.000 2453.601 3653.190 0.000 0.000 0.000 0.000 0.000 0.000 0.000
October 0.273095E+12 179614.886 01-OCT-16:15 11327.174 57042.023 20924.025 0.000 82227.231 0.000 2453.601 3653.190 0.000 0.000 0.000 0.000 0.000 0.000 0.000
November 0.239189E+12 175635.483 27-NOV-17:30 11327.174 57142.088 20924.025 0.000 68168.264 10364.000 2453.601 3261.173 0.000 0.000 0.000 0.000 0.000 0.000 0.000
December 0.223531E+12 144008.962 08-DEC-17:30 11327.174 57142.088 20924.025 0.000 37753.934 10364.000 2453.601 2048.982 0.000 0.000 0.000 0.000 0.000 0.000 0.000
                                     
Annual Sum or Average 0.338678E+13                     0.000 0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.205752E+12 130650.694   11327.174 49889.926 20924.025 0.000 0.000 0.000 2453.601 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.371650E+12 189408.373   14401.373 57142.088 20924.025 30976.465 90227.266 10364.000 2453.601 3653.190 0.000 0.000 0.000 0.000 0.000 0.000 0.000



Table of Contents

Report: COMPONENTS OF PEAK GAS DEMAND

For: Meter

Timestamp: 2015-09-09 19:11:57

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC [Invalid/Undefined] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT {AT MAX/MIN} [W] WATERSYSTEMS:GAS {AT MAX/MIN} [W] WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] HEATING:GAS {AT MAX/MIN} [W]
January 0.143249E+12 208344.740 22-JAN-07:15 0.000 0.000 0.000 208344.740 73953.590 73953.590 134391.150
February 0.124621E+12 278005.552 11-FEB-06:45 0.000 0.000 0.000 278005.552 72689.019 72689.019 205316.533
March 0.974440E+11 158569.136 19-MAR-05:30 0.000 0.000 0.000 158569.136 70205.474 70205.474 88363.662
April 0.777382E+11 72747.416 01-APR-06:00 0.000 0.000 0.000 72747.416 72747.416 72747.416 0.000
May 0.743155E+11 70981.441 01-MAY-06:45 0.000 0.000 0.000 70981.441 70981.441 70981.441 0.000
June 0.670852E+11 69265.839 02-JUN-06:45 0.000 0.000 0.000 69265.839 69265.839 69265.839 0.000
July 0.666606E+11 68132.615 06-JUL-06:45 0.000 0.000 0.000 68132.615 68132.615 68132.615 0.000
August 0.670914E+11 68343.992 30-AUG-06:30 0.000 0.000 0.000 68343.992 68343.992 68343.992 0.000
September 0.681951E+11 69593.401 28-SEP-06:45 0.000 0.000 0.000 69593.401 69593.401 69593.401 0.000
October 0.758837E+11 71329.204 29-OCT-06:45 0.000 0.000 0.000 71329.204 71329.204 71329.204 0.000
November 0.820737E+11 126452.359 10-NOV-06:30 0.000 0.000 0.000 126452.359 69115.940 69115.940 57336.419
December 0.115028E+12 178471.250 21-DEC-06:45 0.000 0.000 0.000 178471.250 72180.690 72180.690 106290.560
                     
Annual Sum or Average 0.105939E+13     0.000 0.000 0.000        
Minimum of Months 0.666606E+11 68132.615   0.000 0.000 0.000 68132.615 68132.615 68132.615 0.000
Maximum of Months 0.143249E+12 278005.552   0.000 0.000 0.000 278005.552 73953.590 73953.590 205316.533