Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:59

Tabular Output Report in Format: HTML

Building: High-Rise Apartment

Environment: Burlington International Ap VT USA TMY3 WMO#=726170

Simulation Timestamp: 2015-09-09 19:00:30


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 5745.17 733.13 813.78
Net Site Energy 5745.17 733.13 813.78
Total Source Energy 12362.72 1577.59 1751.12
Net Source Energy 12362.72 1577.59 1751.12


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 7836.48
Net Conditioned Building Area 7059.89
Unconditioned Building Area 776.58


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 402.19 1558.07 0.00 0.00 0.00 0.00
Cooling 230.30 0.00 0.00 0.00 0.00 0.00
Interior Lighting 296.56 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 162.69 0.00 0.00 0.00 0.00 0.00
Interior Equipment 1137.32 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 605.54 0.00 0.00 0.00 0.00 0.00
Pumps 64.33 0.00 0.00 0.00 0.00 0.00
Heat Rejection 10.13 0.00 0.00 0.00 0.00 692.77
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 1241.86 0.00 0.00 0.00 4778.51
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 2945.25 2799.92 0.00 0.00 0.00 5471.28
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating Boiler 0.00 1558.07 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
  Other 402.19 0.00 0.00 0.00 0.00 0.00
Cooling General 230.30 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 242.55 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 54.01 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 162.69 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 1137.32 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 605.54 0.00 0.00 0.00 0.00 0.00
Pumps General 64.33 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 10.13 0.00 0.00 0.00 0.00 692.77
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 1241.86 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 4778.51
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 65.05 0.00 0.00 0.00 0.00 0.00
HVAC 185.91 396.60 0.00 0.00 0.00 0.77
Other 161.10 0.00 0.00 0.00 0.00 0.00
Total 417.18 396.60 0.00 0.00 0.00 0.77


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 58.60 0.00 0.00 0.00 0.00 0.00
HVAC 167.49 357.29 0.00 0.00 0.00 0.70
Other 145.13 0.00 0.00 0.00 0.00 0.00
Total 375.84 357.29 0.00 0.00 0.00 0.70


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 2945.25 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 2945.25 100.00
     
Total On-Site and Utility Electric Sources 2945.25 100.00
Total Electricity End Uses 2945.25 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 5471.28 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 5471.28 100.00
Total Water End Uses 5471.28 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 120.25
Time Setpoint Not Met During Occupied Cooling 100.50
Time Not Comfortable Based on Simple ASHRAE 55-2004 3353.75


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |

COMPONENTS OF PEAK ELECTRICAL DEMAND

| Meter |

COMPONENTS OF PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:59
RunPeriod Burlington International Ap VT USA TMY3 WMO#=726170
Weather File Burlington International Ap VT USA TMY3 WMO#=726170
Latitude [deg] 44.47
Longitude [deg] -73.2
Elevation [m] 101.00
Time Zone -5.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3855.02 1411.96 515.55 1411.96 515.55
Window Opening Area [m2] 1150.39 423.59 152.73 423.59 150.48
Window-Wall Ratio [%] 29.84 30.00 29.62 30.00 29.19


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3752.84 1411.96 464.46 1411.96 464.46
Window Opening Area [m2] 1125.85 423.59 139.34 423.59 139.34
Window-Wall Ratio [%] 30.00 30.00 30.00 30.00 30.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
OFFICE 88.25 Yes Yes 268.96 1.00 58.52 17.56 29.5362 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 4.47 6.7128   0.0000
F2 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F3 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F4 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
M SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
M CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 13.4255   0.0000
F6 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F7 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F8 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F9 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
T SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   264.3872
Total 7836.48     23884.04   3855.02 1150.39 4.3335 39.48 8.6291
Conditioned Total 7059.89     21517.16   3752.84 1125.85 3.9979 35.57 6.6700
Unconditioned Total 776.58     2366.87   102.18 24.54 7.3840   26.4387
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 07-FEB-17:00 24-JAN-07:30 - - - 20-JUL-17:15
Heating 87652.69 287983.24 0.00 0.00 0.00 0.00
Cooling 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 11327.17 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 10364.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 57142.09 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 19201.55 0.00 0.00 0.00 0.00 0.00
Pumps 2079.88 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 84624.48 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 189762.54 372607.72 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating Boiler 0.00 287983.24 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 9220.52 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 2106.65 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 10364.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 57142.09 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 19201.55 0.00 0.00 0.00 0.00 0.00
Pumps General 2079.88 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 84624.48 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 1273.75 1688.94 0.00 0.00 0.00
Cooling 729.37 0.00 0.00 0.00 0.00
Interior Lighting 939.20 0.00 0.00 0.00 0.00
Exterior Lighting 515.25 0.00 0.00 0.00 0.00
Interior Equipment 3601.91 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 1917.75 0.00 0.00 0.00 0.00
Pumps 203.73 0.00 0.00 0.00 0.00
Heat Rejection 32.09 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 1346.17 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 9327.60 3035.12 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 180.42 239.23 0.00 0.00 0.00
Cooling 103.31 0.00 0.00 0.00 0.00
Interior Lighting 133.03 0.00 0.00 0.00 0.00
Exterior Lighting 72.98 0.00 0.00 0.00 0.00
Interior Equipment 510.19 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 271.64 0.00 0.00 0.00 0.00
Pumps 28.86 0.00 0.00 0.00 0.00
Heat Rejection 4.55 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 190.68 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1321.21 429.91 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 180.42 239.23 0.00 0.00 0.00
Cooling 103.31 0.00 0.00 0.00 0.00
Interior Lighting 133.03 0.00 0.00 0.00 0.00
Exterior Lighting 72.98 0.00 0.00 0.00 0.00
Interior Equipment 510.19 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 271.64 0.00 0.00 0.00 0.00
Pumps 28.86 0.00 0.00 0.00 0.00
Heat Rejection 4.55 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 190.68 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1321.21 429.91 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB -22.40 0.00 -22.40 Wetbulb [C] 3.00 60.00
BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 31.30 10.70 21.70 Wetbulb [C] 4.50 170.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G WWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 270.00 180.00  
F2 WWALL SWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
F2 SWALL SWA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F2 NWALL NWA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F2 WWALL NWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
F2 EWALL SEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
F2 SWALL SEA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F2 NWALL NEA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F2 EWALL NEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
F2 NWALL N1A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F2 NWALL N2A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F2 SWALL S1A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F2 SWALL S2A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F2 WWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 270.00 90.00 W
F2 EWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 90.00 90.00 E
F3 WWALL SWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
F3 SWALL SWA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F3 NWALL NWA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F3 WWALL NWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
F3 EWALL SEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
F3 SWALL SEA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F3 NWALL NEA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F3 EWALL NEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
F3 NWALL N1A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F3 NWALL N2A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F3 SWALL S1A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F3 SWALL S2A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F3 WWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 270.00 90.00 W
F3 EWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 90.00 90.00 E
F4 WWALL SWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
F4 SWALL SWA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F4 NWALL NWA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F4 WWALL NWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
F4 EWALL SEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
F4 SWALL SEA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F4 NWALL NEA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F4 EWALL NEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
F4 NWALL N1A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F4 NWALL N2A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F4 SWALL S1A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F4 SWALL S2A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F4 WWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 270.00 90.00 W
F4 EWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 90.00 90.00 E
M WWALL SWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
M WWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 90.00 90.00 E
F6 WWALL SWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
F6 SWALL SWA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F6 NWALL NWA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F6 WWALL NWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
F6 EWALL SEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
F6 SWALL SEA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F6 NWALL NEA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F6 EWALL NEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
F6 NWALL N1A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F6 NWALL N2A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F6 SWALL S1A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F6 SWALL S2A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F6 WWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 270.00 90.00 W
F6 EWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 90.00 90.00 E
F7 WWALL SWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
F7 SWALL SWA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F7 NWALL NWA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F7 WWALL NWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
F7 EWALL SEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
F7 SWALL SEA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F7 NWALL NEA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F7 EWALL NEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
F7 NWALL N1A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F7 NWALL N2A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F7 SWALL S1A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F7 SWALL S2A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F7 WWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 270.00 90.00 W
F7 EWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 90.00 90.00 E
F8 WWALL SWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
F8 SWALL SWA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F8 NWALL NWA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F8 WWALL NWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
F8 EWALL SEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
F8 SWALL SEA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F8 NWALL NEA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F8 EWALL NEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
F8 NWALL N1A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F8 NWALL N2A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F8 SWALL S1A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F8 SWALL S2A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F8 WWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 270.00 90.00 W
F8 EWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 90.00 90.00 E
F9 WWALL SWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
F9 SWALL SWA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F9 NWALL NWA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F9 WWALL NWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
F9 EWALL SEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
F9 SWALL SEA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F9 NWALL NEA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F9 EWALL NEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
F9 NWALL N1A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F9 NWALL N2A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
F9 SWALL S1A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F9 SWALL S2A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
F9 WWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 270.00 90.00 W
F9 EWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 90.00 90.00 E
T WWALL SWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.30 0.269 0.283 77.66 0.00 0.00  


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL SWA 180.00 90.00 S
GWINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G WWALL SWA 270.00 90.00 W
GWINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL NWA 0.00 90.00 N
GWINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G WWALL NWA 270.00 90.00 W
GWINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL SEA 180.00 90.00 S
GWINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G EWALL SEA 90.00 90.00 E
GWINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL NEA 0.00 90.00 N
GWINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G EWALL NEA 90.00 90.00 E
GWINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL N1A 0.00 90.00 N
GWINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL N2A 0.00 90.00 N
GWINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL S1A 180.00 90.00 S
GWINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL S2A 180.00 90.00 S
GWINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No G WWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.48_SHGC_0.40 3.36 0.00 0.00 3.36 3.36 2.653 0.426 0.308     No G EWALL C 90.00 90.00 E
F2WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 WWALL SWA 270.00 90.00 W
F2WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL SWA 180.00 90.00 S
F2WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL NWA 0.00 90.00 N
F2WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 WWALL NWA 270.00 90.00 W
F2WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 EWALL SEA 90.00 90.00 E
F2WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL SEA 180.00 90.00 S
F2WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL NEA 0.00 90.00 N
F2WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 EWALL NEA 90.00 90.00 E
F2WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL N1A 0.00 90.00 N
F2WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL N2A 0.00 90.00 N
F2WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL S1A 180.00 90.00 S
F2WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL S2A 180.00 90.00 S
F2WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F2 WWALL C 270.00 90.00 W
F2WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F2 EWALL C 90.00 90.00 E
F3WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 WWALL SWA 270.00 90.00 W
F3WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL SWA 180.00 90.00 S
F3WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL NWA 0.00 90.00 N
F3WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 WWALL NWA 270.00 90.00 W
F3WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 EWALL SEA 90.00 90.00 E
F3WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL SEA 180.00 90.00 S
F3WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL NEA 0.00 90.00 N
F3WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 EWALL NEA 90.00 90.00 E
F3WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL N1A 0.00 90.00 N
F3WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL N2A 0.00 90.00 N
F3WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL S1A 180.00 90.00 S
F3WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL S2A 180.00 90.00 S
F3WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F3 WWALL C 270.00 90.00 W
F3WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F3 EWALL C 90.00 90.00 E
F4WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 WWALL SWA 270.00 90.00 W
F4WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL SWA 180.00 90.00 S
F4WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL NWA 0.00 90.00 N
F4WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 WWALL NWA 270.00 90.00 W
F4WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 EWALL SEA 90.00 90.00 E
F4WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL SEA 180.00 90.00 S
F4WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL NEA 0.00 90.00 N
F4WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 EWALL NEA 90.00 90.00 E
F4WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL N1A 0.00 90.00 N
F4WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL N2A 0.00 90.00 N
F4WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL S1A 180.00 90.00 S
F4WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL S2A 180.00 90.00 S
F4WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F4 WWALL C 270.00 90.00 W
F4WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F4 EWALL C 90.00 90.00 E
MWINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M WWALL SWA 270.00 90.00 W
MWINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL SWA 180.00 90.00 S
MWINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL NWA 0.00 90.00 N
MWINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M WWALL NWA 270.00 90.00 W
MWINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M EWALL SEA 90.00 90.00 E
MWINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL SEA 180.00 90.00 S
MWINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL NEA 0.00 90.00 N
MWINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M EWALL NEA 90.00 90.00 E
MWINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL N1A 0.00 90.00 N
MWINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL N2A 0.00 90.00 N
MWINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL S1A 180.00 90.00 S
MWINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL S2A 180.00 90.00 S
MWINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No M WWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No M EWALL C 90.00 90.00 E
F6WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 WWALL SWA 270.00 90.00 W
F6WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL SWA 180.00 90.00 S
F6WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL NWA 0.00 90.00 N
F6WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 WWALL NWA 270.00 90.00 W
F6WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 EWALL SEA 90.00 90.00 E
F6WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL SEA 180.00 90.00 S
F6WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL NEA 0.00 90.00 N
F6WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 EWALL NEA 90.00 90.00 E
F6WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL N1A 0.00 90.00 N
F6WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL N2A 0.00 90.00 N
F6WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL S1A 180.00 90.00 S
F6WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL S2A 180.00 90.00 S
F6WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F6 WWALL C 270.00 90.00 W
F6WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F6 EWALL C 90.00 90.00 E
F7WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 WWALL SWA 270.00 90.00 W
F7WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL SWA 180.00 90.00 S
F7WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL NWA 0.00 90.00 N
F7WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 WWALL NWA 270.00 90.00 W
F7WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 EWALL SEA 90.00 90.00 E
F7WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL SEA 180.00 90.00 S
F7WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL NEA 0.00 90.00 N
F7WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 EWALL NEA 90.00 90.00 E
F7WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL N1A 0.00 90.00 N
F7WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL N2A 0.00 90.00 N
F7WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL S1A 180.00 90.00 S
F7WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL S2A 180.00 90.00 S
F7WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F7 WWALL C 270.00 90.00 W
F7WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F7 EWALL C 90.00 90.00 E
F8WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 WWALL SWA 270.00 90.00 W
F8WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL SWA 180.00 90.00 S
F8WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL NWA 0.00 90.00 N
F8WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 WWALL NWA 270.00 90.00 W
F8WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 EWALL SEA 90.00 90.00 E
F8WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL SEA 180.00 90.00 S
F8WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL NEA 0.00 90.00 N
F8WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 EWALL NEA 90.00 90.00 E
F8WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL N1A 0.00 90.00 N
F8WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL N2A 0.00 90.00 N
F8WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL S1A 180.00 90.00 S
F8WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL S2A 180.00 90.00 S
F8WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F8 WWALL C 270.00 90.00 W
F8WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F8 EWALL C 90.00 90.00 E
F9WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 WWALL SWA 270.00 90.00 W
F9WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL SWA 180.00 90.00 S
F9WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL NWA 0.00 90.00 N
F9WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 WWALL NWA 270.00 90.00 W
F9WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 EWALL SEA 90.00 90.00 E
F9WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL SEA 180.00 90.00 S
F9WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL NEA 0.00 90.00 N
F9WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 EWALL NEA 90.00 90.00 E
F9WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL N1A 0.00 90.00 N
F9WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL N2A 0.00 90.00 N
F9WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL S1A 180.00 90.00 S
F9WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL S2A 180.00 90.00 S
F9WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F9 WWALL C 270.00 90.00 W
F9WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F9 EWALL C 90.00 90.00 E
TWINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T WWALL SWA 270.00 90.00 W
TWINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL SWA 180.00 90.00 S
TWINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL NWA 0.00 90.00 N
TWINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T WWALL NWA 270.00 90.00 W
TWINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T EWALL SEA 90.00 90.00 E
TWINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL SEA 180.00 90.00 S
TWINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL NEA 0.00 90.00 N
TWINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T EWALL NEA 90.00 90.00 E
TWINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL N1A 0.00 90.00 N
TWINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL N2A 0.00 90.00 N
TWINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL S1A 180.00 90.00 S
TWINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL S2A 180.00 90.00 S
TWINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No T WWALL C 270.00 90.00 W
TWINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No T EWALL C 90.00 90.00 E
Total or Average           1150.39 2.653 0.426 0.308              
North Total or Average           423.59 2.653 0.426 0.308              
Non-North Total or Average           726.80 2.653 0.426 0.308              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW2 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
GWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW6 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
GWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW8 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
GWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW7 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
GWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW13 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
F2WINDOW2 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
F2WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW6 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
F2WINDOW8 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
F2WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW7 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
F2WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW13 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
F2WINDOW14 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
F3WINDOW2 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
F3WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW6 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
F3WINDOW8 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
F3WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW7 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
F3WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW13 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
F3WINDOW14 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
F4WINDOW2 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
F4WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW6 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
F4WINDOW8 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
F4WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW7 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
F4WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW13 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
F4WINDOW14 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
MWINDOW2 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
MWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW6 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
MWINDOW8 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
MWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW7 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
MWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW13 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
MWINDOW14 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
F6WINDOW2 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
F6WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW6 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
F6WINDOW8 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
F6WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW7 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
F6WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW13 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
F6WINDOW14 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
F7WINDOW2 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
F7WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW6 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
F7WINDOW8 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
F7WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW7 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
F7WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW13 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
F7WINDOW14 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
F8WINDOW2 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
F8WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW6 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
F8WINDOW8 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
F8WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW7 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
F8WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW13 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
F8WINDOW14 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
F9WINDOW2 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
F9WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW6 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
F9WINDOW8 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
F9WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW7 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
F9WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW13 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
F9WINDOW14 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
TWINDOW2 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
TWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW6 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
TWINDOW8 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
TWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW7 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
TWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW13 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
G SW APARTMENT_LIGHTS_HARDWIRED G SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G NW APARTMENT_LIGHTS_HARDWIRED G NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
OFFICE_LIGHTS_HARDWIRED OFFICE 14.7681 88.25 1303.26 GeneralLights LTG_OFF_SCH 62.05 168.00 61.07 0.0000 Y 14.94
G NE APARTMENT_LIGHTS_HARDWIRED G NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G N1 APARTMENT_LIGHTS_HARDWIRED G N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G N2 APARTMENT_LIGHTS_HARDWIRED G N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G S1 APARTMENT_LIGHTS_HARDWIRED G S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G S2 APARTMENT_LIGHTS_HARDWIRED G S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G CORRIDOR_LIGHTS_HARDWIRED G CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F2 SW APARTMENT_LIGHTS_HARDWIRED F2 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 NW APARTMENT_LIGHTS_HARDWIRED F2 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 SE APARTMENT_LIGHTS_HARDWIRED F2 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 NE APARTMENT_LIGHTS_HARDWIRED F2 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 N1 APARTMENT_LIGHTS_HARDWIRED F2 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 N2 APARTMENT_LIGHTS_HARDWIRED F2 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 S1 APARTMENT_LIGHTS_HARDWIRED F2 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 S2 APARTMENT_LIGHTS_HARDWIRED F2 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 CORRIDOR_LIGHTS_HARDWIRED F2 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F3 SW APARTMENT_LIGHTS_HARDWIRED F3 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 NW APARTMENT_LIGHTS_HARDWIRED F3 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 SE APARTMENT_LIGHTS_HARDWIRED F3 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 NE APARTMENT_LIGHTS_HARDWIRED F3 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 N1 APARTMENT_LIGHTS_HARDWIRED F3 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 N2 APARTMENT_LIGHTS_HARDWIRED F3 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 S1 APARTMENT_LIGHTS_HARDWIRED F3 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 S2 APARTMENT_LIGHTS_HARDWIRED F3 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 CORRIDOR_LIGHTS_HARDWIRED F3 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F4 SW APARTMENT_LIGHTS_HARDWIRED F4 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 NW APARTMENT_LIGHTS_HARDWIRED F4 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 SE APARTMENT_LIGHTS_HARDWIRED F4 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 NE APARTMENT_LIGHTS_HARDWIRED F4 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 N1 APARTMENT_LIGHTS_HARDWIRED F4 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 N2 APARTMENT_LIGHTS_HARDWIRED F4 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 S1 APARTMENT_LIGHTS_HARDWIRED F4 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 S2 APARTMENT_LIGHTS_HARDWIRED F4 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 CORRIDOR_LIGHTS_HARDWIRED F4 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
M SW APARTMENT_LIGHTS_HARDWIRED M SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M NW APARTMENT_LIGHTS_HARDWIRED M NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M SE APARTMENT_LIGHTS_HARDWIRED M SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M NE APARTMENT_LIGHTS_HARDWIRED M NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M N1 APARTMENT_LIGHTS_HARDWIRED M N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M N2 APARTMENT_LIGHTS_HARDWIRED M N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M S1 APARTMENT_LIGHTS_HARDWIRED M S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M S2 APARTMENT_LIGHTS_HARDWIRED M S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M CORRIDOR_LIGHTS_HARDWIRED M CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F6 SW APARTMENT_LIGHTS_HARDWIRED F6 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 NW APARTMENT_LIGHTS_HARDWIRED F6 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 SE APARTMENT_LIGHTS_HARDWIRED F6 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 NE APARTMENT_LIGHTS_HARDWIRED F6 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 N1 APARTMENT_LIGHTS_HARDWIRED F6 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 N2 APARTMENT_LIGHTS_HARDWIRED F6 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 S1 APARTMENT_LIGHTS_HARDWIRED F6 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 S2 APARTMENT_LIGHTS_HARDWIRED F6 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 CORRIDOR_LIGHTS_HARDWIRED F6 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F7 SW APARTMENT_LIGHTS_HARDWIRED F7 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 NW APARTMENT_LIGHTS_HARDWIRED F7 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 SE APARTMENT_LIGHTS_HARDWIRED F7 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 NE APARTMENT_LIGHTS_HARDWIRED F7 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 N1 APARTMENT_LIGHTS_HARDWIRED F7 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 N2 APARTMENT_LIGHTS_HARDWIRED F7 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 S1 APARTMENT_LIGHTS_HARDWIRED F7 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 S2 APARTMENT_LIGHTS_HARDWIRED F7 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 CORRIDOR_LIGHTS_HARDWIRED F7 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F8 SW APARTMENT_LIGHTS_HARDWIRED F8 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 NW APARTMENT_LIGHTS_HARDWIRED F8 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 SE APARTMENT_LIGHTS_HARDWIRED F8 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 NE APARTMENT_LIGHTS_HARDWIRED F8 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 N1 APARTMENT_LIGHTS_HARDWIRED F8 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 N2 APARTMENT_LIGHTS_HARDWIRED F8 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 S1 APARTMENT_LIGHTS_HARDWIRED F8 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 S2 APARTMENT_LIGHTS_HARDWIRED F8 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 CORRIDOR_LIGHTS_HARDWIRED F8 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F9 SW APARTMENT_LIGHTS_HARDWIRED F9 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 NW APARTMENT_LIGHTS_HARDWIRED F9 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 SE APARTMENT_LIGHTS_HARDWIRED F9 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 NE APARTMENT_LIGHTS_HARDWIRED F9 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 N1 APARTMENT_LIGHTS_HARDWIRED F9 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 N2 APARTMENT_LIGHTS_HARDWIRED F9 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 S1 APARTMENT_LIGHTS_HARDWIRED F9 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 S2 APARTMENT_LIGHTS_HARDWIRED F9 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 CORRIDOR_LIGHTS_HARDWIRED F9 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
T SW APARTMENT_LIGHTS_HARDWIRED T SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T NW APARTMENT_LIGHTS_HARDWIRED T NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T SE APARTMENT_LIGHTS_HARDWIRED T SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T NE APARTMENT_LIGHTS_HARDWIRED T NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T N1 APARTMENT_LIGHTS_HARDWIRED T N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T N2 APARTMENT_LIGHTS_HARDWIRED T N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T S1 APARTMENT_LIGHTS_HARDWIRED T S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T S2 APARTMENT_LIGHTS_HARDWIRED T S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T CORRIDOR_LIGHTS_HARDWIRED T CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
G SW APARTMENT_LIGHTS_PLUGIN G SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G NW APARTMENT_LIGHTS_PLUGIN G NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
OFFICE_LIGHTS_PLUGIN OFFICE 14.7681 88.25 1303.26 GeneralLights-plugin LTG_OFF_SCH 62.05 168.00 61.07 0.0000 Y 14.94
G NE APARTMENT_LIGHTS_PLUGIN G NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G N1 APARTMENT_LIGHTS_PLUGIN G N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G N2 APARTMENT_LIGHTS_PLUGIN G N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G S1 APARTMENT_LIGHTS_PLUGIN G S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G S2 APARTMENT_LIGHTS_PLUGIN G S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 SW APARTMENT_LIGHTS_PLUGIN F2 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 NW APARTMENT_LIGHTS_PLUGIN F2 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 SE APARTMENT_LIGHTS_PLUGIN F2 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 NE APARTMENT_LIGHTS_PLUGIN F2 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 N1 APARTMENT_LIGHTS_PLUGIN F2 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 N2 APARTMENT_LIGHTS_PLUGIN F2 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 S1 APARTMENT_LIGHTS_PLUGIN F2 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 S2 APARTMENT_LIGHTS_PLUGIN F2 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 SW APARTMENT_LIGHTS_PLUGIN F3 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 NW APARTMENT_LIGHTS_PLUGIN F3 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 SE APARTMENT_LIGHTS_PLUGIN F3 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 NE APARTMENT_LIGHTS_PLUGIN F3 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 N1 APARTMENT_LIGHTS_PLUGIN F3 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 N2 APARTMENT_LIGHTS_PLUGIN F3 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 S1 APARTMENT_LIGHTS_PLUGIN F3 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 S2 APARTMENT_LIGHTS_PLUGIN F3 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 SW APARTMENT_LIGHTS_PLUGIN F4 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 NW APARTMENT_LIGHTS_PLUGIN F4 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 SE APARTMENT_LIGHTS_PLUGIN F4 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 NE APARTMENT_LIGHTS_PLUGIN F4 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 N1 APARTMENT_LIGHTS_PLUGIN F4 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 N2 APARTMENT_LIGHTS_PLUGIN F4 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 S1 APARTMENT_LIGHTS_PLUGIN F4 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 S2 APARTMENT_LIGHTS_PLUGIN F4 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M SW APARTMENT_LIGHTS_PLUGIN M SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M NW APARTMENT_LIGHTS_PLUGIN M NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M SE APARTMENT_LIGHTS_PLUGIN M SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M NE APARTMENT_LIGHTS_PLUGIN M NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M N1 APARTMENT_LIGHTS_PLUGIN M N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M N2 APARTMENT_LIGHTS_PLUGIN M N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M S1 APARTMENT_LIGHTS_PLUGIN M S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M S2 APARTMENT_LIGHTS_PLUGIN M S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M CORRIDOR_LIGHTS_PLUGIN M CORRIDOR 6.7128 77.66 521.30 GeneralLights-plugin LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F6 SW APARTMENT_LIGHTS_PLUGIN F6 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 NW APARTMENT_LIGHTS_PLUGIN F6 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 SE APARTMENT_LIGHTS_PLUGIN F6 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 NE APARTMENT_LIGHTS_PLUGIN F6 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 N1 APARTMENT_LIGHTS_PLUGIN F6 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 N2 APARTMENT_LIGHTS_PLUGIN F6 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 S1 APARTMENT_LIGHTS_PLUGIN F6 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 S2 APARTMENT_LIGHTS_PLUGIN F6 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 SW APARTMENT_LIGHTS_PLUGIN F7 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 NW APARTMENT_LIGHTS_PLUGIN F7 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 SE APARTMENT_LIGHTS_PLUGIN F7 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 NE APARTMENT_LIGHTS_PLUGIN F7 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 N1 APARTMENT_LIGHTS_PLUGIN F7 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 N2 APARTMENT_LIGHTS_PLUGIN F7 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 S1 APARTMENT_LIGHTS_PLUGIN F7 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 S2 APARTMENT_LIGHTS_PLUGIN F7 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 SW APARTMENT_LIGHTS_PLUGIN F8 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 NW APARTMENT_LIGHTS_PLUGIN F8 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 SE APARTMENT_LIGHTS_PLUGIN F8 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 NE APARTMENT_LIGHTS_PLUGIN F8 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 N1 APARTMENT_LIGHTS_PLUGIN F8 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 N2 APARTMENT_LIGHTS_PLUGIN F8 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 S1 APARTMENT_LIGHTS_PLUGIN F8 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 S2 APARTMENT_LIGHTS_PLUGIN F8 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 SW APARTMENT_LIGHTS_PLUGIN F9 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 NW APARTMENT_LIGHTS_PLUGIN F9 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 SE APARTMENT_LIGHTS_PLUGIN F9 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 NE APARTMENT_LIGHTS_PLUGIN F9 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 N1 APARTMENT_LIGHTS_PLUGIN F9 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 N2 APARTMENT_LIGHTS_PLUGIN F9 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 S1 APARTMENT_LIGHTS_PLUGIN F9 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 S2 APARTMENT_LIGHTS_PLUGIN F9 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T SW APARTMENT_LIGHTS_PLUGIN T SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T NW APARTMENT_LIGHTS_PLUGIN T NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T SE APARTMENT_LIGHTS_PLUGIN T SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T NE APARTMENT_LIGHTS_PLUGIN T NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T N1 APARTMENT_LIGHTS_PLUGIN T N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T N2 APARTMENT_LIGHTS_PLUGIN T N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T S1 APARTMENT_LIGHTS_PLUGIN T S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T S2 APARTMENT_LIGHTS_PLUGIN T S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
Interior Lighting Total   2.2679 14974.03 33959.19               296.56


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 10364.00 AstronomicalClock -   83.63 83.63 162.69
Exterior Lighting Total 10364.00           162.69



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
CENTRAL BOILER Boiler:HotWater 294118.77 0.75    
CENTRAL TOWER EvaporativeFluidCooler:SingleSpeed 235295.01      


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
HEAT PUMP COOLING MODE AIRLOOP G SW Coil:Cooling:WaterToAirHeatPump:EquationFit   3615.89 2481.30 1134.59 0.69 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3274.33 2230.09 1044.25 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP OFFICE Coil:Cooling:WaterToAirHeatPump:EquationFit   5487.24 3826.54 1660.70 0.70 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2865.06 1896.97 968.09 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2114.52 1356.97 757.55 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2123.52 1360.25 763.27 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2486.75 1648.50 838.25 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2576.07 1716.41 859.66 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4609.02 3210.05 1398.97 0.70 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4198.77 2900.91 1297.85 0.69 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4567.41 3173.61 1393.80 0.69 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3291.40 2228.56 1062.83 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2426.09 1602.37 823.72 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2406.11 1587.54 818.58 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3198.48 2171.12 1027.37 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3231.48 2196.27 1035.20 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4689.66 3251.77 1437.89 0.69 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4289.48 2951.12 1338.36 0.69 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4359.19 2995.77 1363.42 0.69 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3387.18 2282.92 1104.26 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2510.47 1656.44 854.03 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2490.59 1641.71 848.88 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3281.95 2223.57 1058.38 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3296.98 2235.04 1061.94 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4748.68 3280.84 1467.85 0.69 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4343.30 2978.20 1365.10 0.69 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4383.30 3000.22 1383.08 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3427.72 2301.36 1126.36 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2550.81 1679.95 870.86 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2530.89 1665.22 865.67 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3320.96 2245.02 1075.95 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3333.37 2254.48 1078.89 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4819.33 3322.83 1496.50 0.69 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4414.47 3021.03 1393.44 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4450.14 3039.74 1410.40 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3487.52 2336.60 1150.92 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2609.34 1718.17 891.17 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2589.43 1703.46 885.97 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3378.20 2281.80 1096.41 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3390.20 2290.93 1099.26 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4804.55 3301.81 1502.74 0.69 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4397.84 2999.26 1398.58 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4435.03 3019.02 1416.01 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3461.88 2309.49 1152.39 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2584.31 1695.28 889.03 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2564.43 1680.65 883.78 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3352.94 2257.15 1095.79 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3364.87 2266.22 1098.65 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4815.47 3301.59 1513.88 0.69 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4408.15 2999.08 1409.07 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4448.89 3020.82 1428.07 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3463.85 2304.16 1159.69 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2586.42 1693.12 893.30 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2566.57 1678.54 888.03 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3354.25 2253.34 1100.91 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3366.15 2262.39 1103.77 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4840.81 3313.23 1527.58 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4433.65 3011.23 1422.42 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4473.98 3032.63 1441.36 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3480.66 2310.70 1169.96 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2605.10 1703.60 901.50 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2585.31 1689.08 896.23 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3370.65 2261.47 1109.19 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3382.56 2270.50 1112.06 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4976.17 3409.99 1566.19 0.69 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4578.53 3113.66 1464.87 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4586.19 3110.55 1475.64 0.68 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3550.26 2355.27 1194.99 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2727.79 1790.96 936.83 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2707.68 1776.18 931.51 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3463.06 2326.54 1136.52 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3474.79 2335.45 1139.34 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5999.32 4173.57 1825.75 0.70 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5415.59 3736.12 1679.48 0.69 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SE Coil:Cooling:WaterToAirHeatPump:EquationFit   5496.21 3792.90 1703.31 0.69 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4353.25 2928.18 1425.07 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3402.57 2276.94 1125.64 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3399.99 2274.85 1125.14 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   4504.17 3112.60 1391.58 0.69 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   4515.29 3121.14 1394.15 0.69 0.00    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
None            


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
HEAT PUMP HEATING MODE AIRLOOP G SW Coil:Heating:WaterToAirHeatPump:EquationFit   3615.89 0.00
HEAT PUMP HEATING MODE AIRLOOP G NW Coil:Heating:WaterToAirHeatPump:EquationFit   3274.33 0.00
HEAT PUMP HEATING MODE AIRLOOP OFFICE Coil:Heating:WaterToAirHeatPump:EquationFit   5487.24 0.00
HEAT PUMP HEATING MODE AIRLOOP G NE Coil:Heating:WaterToAirHeatPump:EquationFit   2865.06 0.00
HEAT PUMP HEATING MODE AIRLOOP G N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2114.52 0.00
HEAT PUMP HEATING MODE AIRLOOP G N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2123.52 0.00
HEAT PUMP HEATING MODE AIRLOOP G S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2486.75 0.00
HEAT PUMP HEATING MODE AIRLOOP G S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2576.07 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4609.02 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4198.77 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4567.41 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3291.40 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2426.09 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2406.11 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3198.48 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3231.48 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4689.66 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4289.48 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4359.19 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3387.18 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2510.47 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2490.59 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3281.95 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3296.98 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4748.68 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4343.30 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4383.30 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3427.72 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2550.81 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2530.89 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3320.96 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3333.37 0.00
HEAT PUMP HEATING MODE AIRLOOP M SW Coil:Heating:WaterToAirHeatPump:EquationFit   4819.33 0.00
HEAT PUMP HEATING MODE AIRLOOP M NW Coil:Heating:WaterToAirHeatPump:EquationFit   4414.47 0.00
HEAT PUMP HEATING MODE AIRLOOP M SE Coil:Heating:WaterToAirHeatPump:EquationFit   4450.14 0.00
HEAT PUMP HEATING MODE AIRLOOP M NE Coil:Heating:WaterToAirHeatPump:EquationFit   3487.52 0.00
HEAT PUMP HEATING MODE AIRLOOP M N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2609.34 0.00
HEAT PUMP HEATING MODE AIRLOOP M N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2589.43 0.00
HEAT PUMP HEATING MODE AIRLOOP M S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3378.20 0.00
HEAT PUMP HEATING MODE AIRLOOP M S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3390.20 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4804.55 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4397.84 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4435.03 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3461.88 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2584.31 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2564.43 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3352.94 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3364.87 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4815.47 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4408.15 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4448.89 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3463.85 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2586.42 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2566.57 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3354.25 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3366.15 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4840.81 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4433.65 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4473.98 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3480.66 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2605.10 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2585.31 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3370.65 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3382.56 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4976.17 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4578.53 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4586.19 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3550.26 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2727.79 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2707.68 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3463.06 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3474.79 0.00
HEAT PUMP HEATING MODE AIRLOOP T SW Coil:Heating:WaterToAirHeatPump:EquationFit   5999.32 0.00
HEAT PUMP HEATING MODE AIRLOOP T NW Coil:Heating:WaterToAirHeatPump:EquationFit   5415.59 0.00
HEAT PUMP HEATING MODE AIRLOOP T SE Coil:Heating:WaterToAirHeatPump:EquationFit   5496.21 0.00
HEAT PUMP HEATING MODE AIRLOOP T NE Coil:Heating:WaterToAirHeatPump:EquationFit   4353.25 0.00
HEAT PUMP HEATING MODE AIRLOOP T N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3402.57 0.00
HEAT PUMP HEATING MODE AIRLOOP T N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3399.99 0.00
HEAT PUMP HEATING MODE AIRLOOP T S1 Coil:Heating:WaterToAirHeatPump:EquationFit   4504.17 0.00
HEAT PUMP HEATING MODE AIRLOOP T S2 Coil:Heating:WaterToAirHeatPump:EquationFit   4515.29 0.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW Coil:Heating:Electric   4791.42 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW Coil:Heating:Electric   4792.71 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE Coil:Heating:Electric   5842.94 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE Coil:Heating:Electric   4787.47 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 Coil:Heating:Electric   3709.69 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 Coil:Heating:Electric   3709.57 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 Coil:Heating:Electric   3705.85 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 Coil:Heating:Electric   3712.01 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW Coil:Heating:Electric   4635.62 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW Coil:Heating:Electric   4629.05 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE Coil:Heating:Electric   4650.10 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE Coil:Heating:Electric   4625.42 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 Coil:Heating:Electric   3290.66 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 Coil:Heating:Electric   3290.58 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 Coil:Heating:Electric   3300.33 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 Coil:Heating:Electric   3301.36 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW Coil:Heating:Electric   4687.04 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW Coil:Heating:Electric   4685.82 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE Coil:Heating:Electric   4687.32 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE Coil:Heating:Electric   4684.26 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 Coil:Heating:Electric   3270.88 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 Coil:Heating:Electric   3270.85 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 Coil:Heating:Electric   3273.27 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 Coil:Heating:Electric   3273.39 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW Coil:Heating:Electric   4808.92 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW Coil:Heating:Electric   4811.12 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE Coil:Heating:Electric   4809.21 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE Coil:Heating:Electric   4811.23 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 Coil:Heating:Electric   3334.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 Coil:Heating:Electric   3334.66 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 Coil:Heating:Electric   3333.33 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 Coil:Heating:Electric   3333.35 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW Coil:Heating:Electric   4901.86 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW Coil:Heating:Electric   4905.43 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE Coil:Heating:Electric   4903.41 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE Coil:Heating:Electric   4906.96 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 Coil:Heating:Electric   3379.84 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 Coil:Heating:Electric   3379.87 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 Coil:Heating:Electric   3377.05 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 Coil:Heating:Electric   3377.08 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW Coil:Heating:Electric   5046.01 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW Coil:Heating:Electric   5052.40 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE Coil:Heating:Electric   5048.77 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE Coil:Heating:Electric   5055.16 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 Coil:Heating:Electric   3482.67 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 Coil:Heating:Electric   3482.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 Coil:Heating:Electric   3477.05 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 Coil:Heating:Electric   3477.11 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW Coil:Heating:Electric   5156.64 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW Coil:Heating:Electric   5164.48 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE Coil:Heating:Electric   5160.47 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE Coil:Heating:Electric   5168.32 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 Coil:Heating:Electric   3557.01 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 Coil:Heating:Electric   3557.10 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 Coil:Heating:Electric   3549.93 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 Coil:Heating:Electric   3550.02 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW Coil:Heating:Electric   5270.43 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW Coil:Heating:Electric   5279.20 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE Coil:Heating:Electric   5275.22 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE Coil:Heating:Electric   5283.99 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 Coil:Heating:Electric   3638.12 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 Coil:Heating:Electric   3638.22 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 Coil:Heating:Electric   3630.10 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 Coil:Heating:Electric   3630.21 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW Coil:Heating:Electric   5546.58 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW Coil:Heating:Electric   5553.04 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE Coil:Heating:Electric   5552.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE Coil:Heating:Electric   5558.75 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 Coil:Heating:Electric   3870.79 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 Coil:Heating:Electric   3870.92 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 Coil:Heating:Electric   3864.63 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 Coil:Heating:Electric   3864.76 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW Coil:Heating:Electric   6473.79 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW Coil:Heating:Electric   6489.18 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE Coil:Heating:Electric   6479.78 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE Coil:Heating:Electric   6495.17 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 Coil:Heating:Electric   4848.84 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 Coil:Heating:Electric   4848.98 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 Coil:Heating:Electric   4830.67 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 Coil:Heating:Electric   4830.81 1.00


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
AIRLOOP G SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 242.07 1160.84 1.00 General
AIRLOOP G NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 217.30 1160.84 1.00 General
AIRLOOP OFFICE SUPPLY FAN Fan:OnOff 0.54 622.50 0.33 378.19 1160.84 1.00 General
AIRLOOP G NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 181.36 1160.84 1.00 General
AIRLOOP G N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.11 124.19 1160.84 1.00 General
AIRLOOP G N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.11 124.19 1160.84 1.00 General
AIRLOOP G S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 154.27 1160.84 1.00 General
AIRLOOP G S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 161.57 1160.84 1.00 General
AIRLOOP F2 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.27 318.99 1160.84 1.00 General
AIRLOOP F2 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 287.18 1160.84 1.00 General
AIRLOOP F2 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.27 314.13 1160.84 1.00 General
AIRLOOP F2 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 217.75 1160.84 1.00 General
AIRLOOP F2 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 152.11 1160.84 1.00 General
AIRLOOP F2 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 150.52 1160.84 1.00 General
AIRLOOP F2 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 209.09 1160.84 1.00 General
AIRLOOP F2 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 211.79 1160.84 1.00 General
AIRLOOP F3 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 322.15 1160.84 1.00 General
AIRLOOP F3 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 291.28 1160.84 1.00 General
AIRLOOP F3 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 293.72 1160.84 1.00 General
AIRLOOP F3 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 221.87 1160.84 1.00 General
AIRLOOP F3 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 157.18 1160.84 1.00 General
AIRLOOP F3 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 155.61 1160.84 1.00 General
AIRLOOP F3 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 213.94 1160.84 1.00 General
AIRLOOP F3 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 215.17 1160.84 1.00 General
AIRLOOP F4 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 324.00 1160.84 1.00 General
AIRLOOP F4 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 293.23 1160.84 1.00 General
AIRLOOP F4 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 293.24 1160.84 1.00 General
AIRLOOP F4 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 222.94 1160.84 1.00 General
AIRLOOP F4 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 159.17 1160.84 1.00 General
AIRLOOP F4 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 157.60 1160.84 1.00 General
AIRLOOP F4 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 215.66 1160.84 1.00 General
AIRLOOP F4 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 216.68 1160.84 1.00 General
AIRLOOP M SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 327.70 1160.84 1.00 General
AIRLOOP M NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 297.04 1160.84 1.00 General
AIRLOOP M SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 296.69 1160.84 1.00 General
AIRLOOP M NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 225.98 1160.84 1.00 General
AIRLOOP M N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 162.82 1160.84 1.00 General
AIRLOOP M N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 161.25 1160.84 1.00 General
AIRLOOP M S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 219.13 1160.84 1.00 General
AIRLOOP M S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 220.11 1160.84 1.00 General
AIRLOOP F6 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 324.77 1160.84 1.00 General
AIRLOOP F6 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 294.05 1160.84 1.00 General
AIRLOOP F6 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 293.81 1160.84 1.00 General
AIRLOOP F6 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 222.46 1160.84 1.00 General
AIRLOOP F6 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 160.01 1160.84 1.00 General
AIRLOOP F6 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 158.46 1160.84 1.00 General
AIRLOOP F6 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 216.08 1160.84 1.00 General
AIRLOOP F6 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 217.06 1160.84 1.00 General
AIRLOOP F7 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 324.15 1160.84 1.00 General
AIRLOOP F7 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 293.46 1160.84 1.00 General
AIRLOOP F7 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 293.26 1160.84 1.00 General
AIRLOOP F7 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 221.36 1160.84 1.00 General
AIRLOOP F7 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 159.47 1160.84 1.00 General
AIRLOOP F7 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 157.92 1160.84 1.00 General
AIRLOOP F7 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 215.32 1160.84 1.00 General
AIRLOOP F7 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 216.30 1160.84 1.00 General
AIRLOOP F8 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 324.87 1160.84 1.00 General
AIRLOOP F8 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 294.25 1160.84 1.00 General
AIRLOOP F8 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 294.01 1160.84 1.00 General
AIRLOOP F8 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 221.58 1160.84 1.00 General
AIRLOOP F8 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 160.30 1160.84 1.00 General
AIRLOOP F8 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 158.76 1160.84 1.00 General
AIRLOOP F8 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 215.88 1160.84 1.00 General
AIRLOOP F8 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 216.85 1160.84 1.00 General
AIRLOOP F9 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.29 335.05 1160.84 1.00 General
AIRLOOP F9 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 304.73 1160.84 1.00 General
AIRLOOP F9 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 301.87 1160.84 1.00 General
AIRLOOP F9 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 225.40 1160.84 1.00 General
AIRLOOP F9 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.15 169.35 1160.84 1.00 General
AIRLOOP F9 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 167.78 1160.84 1.00 General
AIRLOOP F9 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 222.39 1160.84 1.00 General
AIRLOOP F9 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 223.35 1160.84 1.00 General
AIRLOOP T SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.36 415.22 1160.84 1.00 General
AIRLOOP T NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 369.55 1160.84 1.00 General
AIRLOOP T SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 374.70 1160.84 1.00 General
AIRLOOP T NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 281.60 1160.84 1.00 General
AIRLOOP T N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 216.67 1160.84 1.00 General
AIRLOOP T N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 216.44 1160.84 1.00 General
AIRLOOP T S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 306.59 1160.84 1.00 General
AIRLOOP T S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 307.52 1160.84 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
SHWSYS1 PUMP Pump:ConstantSpeed Intermittent 29891.00 0.0003 36.93 127739.32 0.30
PLANT CIRC PUMP Pump:ConstantSpeed Intermittent 224180.02 0.0064 2042.95 319344.75 0.90


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
SHWSYS1 WATER HEATER WaterHeater:Mixed 2.27 175842.64 0.80 0.00 0.00



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 2192.67 2631.20 0.174 0.209 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 15:45:00 30.82 0.01255
G NW APARTMENT 1968.41 2362.09 0.156 0.187 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 29.00 0.01255
OFFICE 3425.75 4110.90 0.271 0.326 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:15:00 30.90 0.01255
G NE APARTMENT 1424.52 1709.42 0.113 0.135 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 09:45:00 26.78 0.01255
G N1 APARTMENT 974.12 1168.94 0.077 0.093 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
G N2 APARTMENT 957.28 1148.73 0.076 0.091 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
G S1 APARTMENT 1397.42 1676.90 0.111 0.133 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
G S2 APARTMENT 1463.58 1756.29 0.116 0.139 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
F2 SW APARTMENT 2889.45 3467.34 0.229 0.275 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 30.23 0.01255
F2 NW APARTMENT 2601.35 3121.62 0.206 0.247 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 29.00 0.01255
F2 SE APARTMENT 2845.42 3414.51 0.226 0.271 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:15:00 30.90 0.01255
F2 NE APARTMENT 1972.36 2366.84 0.156 0.188 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 10:00:00 27.23 0.01255
F2 N1 APARTMENT 1377.84 1653.41 0.109 0.131 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
F2 N2 APARTMENT 1363.51 1636.21 0.108 0.130 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
F2 S1 APARTMENT 1893.98 2272.77 0.150 0.180 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
F2 S2 APARTMENT 1918.49 2302.18 0.152 0.182 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
F3 SW APARTMENT 2918.01 3501.61 0.231 0.278 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 30.23 0.01255
F3 NW APARTMENT 2638.46 3166.15 0.209 0.251 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 29.00 0.01255
F3 SE APARTMENT 2660.48 3192.58 0.211 0.253 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:15:00 30.90 0.01255
F3 NE APARTMENT 2009.68 2411.61 0.159 0.191 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 27.64 0.01255
F3 N1 APARTMENT 1423.80 1708.56 0.113 0.135 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
F3 N2 APARTMENT 1409.56 1691.48 0.112 0.134 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
F3 S1 APARTMENT 1937.91 2325.50 0.154 0.184 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
F3 S2 APARTMENT 1949.09 2338.91 0.154 0.185 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
F4 SW APARTMENT 2934.65 3521.58 0.233 0.279 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 30.44 0.01255
F4 NW APARTMENT 2656.05 3187.26 0.211 0.253 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 29.00 0.01255
F4 SE APARTMENT 2656.04 3187.24 0.211 0.253 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:15:00 30.90 0.01255
F4 NE APARTMENT 2019.33 2423.20 0.160 0.192 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 27.64 0.01255
F4 N1 APARTMENT 1441.76 1730.11 0.114 0.137 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
F4 N2 APARTMENT 1427.54 1713.05 0.113 0.136 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
F4 S1 APARTMENT 1953.46 2344.15 0.155 0.186 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
F4 S2 APARTMENT 1962.68 2355.22 0.156 0.187 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
M SW APARTMENT 2968.19 3561.83 0.235 0.282 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 30.44 0.01255
M NW APARTMENT 2690.58 3228.70 0.213 0.256 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 29.00 0.01255
M SE APARTMENT 2687.31 3224.77 0.213 0.256 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:15:00 30.90 0.01255
M NE APARTMENT 2046.84 2456.21 0.162 0.195 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 27.64 0.01255
M N1 APARTMENT 1474.84 1769.81 0.117 0.140 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
M N2 APARTMENT 1460.65 1752.78 0.116 0.139 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
M S1 APARTMENT 1984.87 2381.84 0.157 0.189 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
M S2 APARTMENT 1993.78 2392.54 0.158 0.190 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
F6 SW APARTMENT 2941.58 3529.89 0.233 0.280 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 30.44 0.01255
F6 NW APARTMENT 2663.47 3196.16 0.211 0.253 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 29.00 0.01255
F6 SE APARTMENT 2661.18 3193.41 0.211 0.253 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:15:00 30.90 0.01255
F6 NE APARTMENT 2014.95 2417.94 0.160 0.192 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 27.64 0.01255
F6 N1 APARTMENT 1449.42 1739.31 0.115 0.138 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
F6 N2 APARTMENT 1435.33 1722.39 0.114 0.137 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
F6 S1 APARTMENT 1957.27 2348.72 0.155 0.186 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
F6 S2 APARTMENT 1966.12 2359.34 0.156 0.187 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
F7 SW APARTMENT 2935.97 3523.16 0.233 0.279 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 30.44 0.01255
F7 NW APARTMENT 2658.08 3189.69 0.211 0.253 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 29.00 0.01255
F7 SE APARTMENT 2656.17 3187.41 0.211 0.253 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
F7 NE APARTMENT 2004.92 2405.90 0.159 0.191 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 27.64 0.01255
F7 N1 APARTMENT 1444.48 1733.38 0.114 0.137 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
F7 N2 APARTMENT 1430.45 1716.54 0.113 0.136 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
F7 S1 APARTMENT 1950.38 2340.46 0.155 0.185 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
F7 S2 APARTMENT 1959.19 2351.03 0.155 0.186 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
F8 SW APARTMENT 2942.45 3530.94 0.233 0.280 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 30.44 0.01255
F8 NW APARTMENT 2665.20 3198.24 0.211 0.253 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 29.00 0.01255
F8 SE APARTMENT 2662.94 3195.53 0.211 0.253 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
F8 NE APARTMENT 2006.91 2408.29 0.159 0.191 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 27.64 0.01255
F8 N1 APARTMENT 1452.04 1742.45 0.115 0.138 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
F8 N2 APARTMENT 1438.08 1725.70 0.114 0.137 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
F8 S1 APARTMENT 1955.40 2346.48 0.155 0.186 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
F8 S2 APARTMENT 1964.20 2357.04 0.156 0.187 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
F9 SW APARTMENT 3034.59 3641.51 0.241 0.289 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 30.23 0.01255
F9 NW APARTMENT 2760.15 3312.18 0.219 0.263 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 29.00 0.01255
F9 SE APARTMENT 2734.11 3280.93 0.217 0.260 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
F9 NE APARTMENT 2041.45 2449.74 0.162 0.194 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 28.04 0.01255
F9 N1 APARTMENT 1533.94 1840.73 0.122 0.146 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
F9 N2 APARTMENT 1519.72 1823.67 0.120 0.145 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
F9 S1 APARTMENT 2014.42 2417.30 0.160 0.192 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 31.17 0.01255
F9 S2 APARTMENT 2023.10 2427.72 0.160 0.192 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 31.17 0.01255
T SW APARTMENT 3760.61 4512.73 0.298 0.358 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 15:15:00 31.14 0.01255
T NW APARTMENT 3347.06 4016.47 0.265 0.318 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 30.23 0.01255
T SE APARTMENT 3393.70 4072.44 0.269 0.323 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:15:00 30.90 0.01255
T NE APARTMENT 2550.43 3060.52 0.202 0.243 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 31.30 0.01255
T N1 APARTMENT 1962.57 2355.09 0.156 0.187 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 14:45:00 31.30 0.01255
T N2 APARTMENT 1960.45 2352.54 0.155 0.186 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 31.30 0.01255
T S1 APARTMENT 2777.04 3332.45 0.220 0.264 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
T S2 APARTMENT 2785.39 3342.47 0.221 0.265 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 2894.61 3473.53 0.130 0.156 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -22.40 0.00051
G NW APARTMENT 2895.70 3474.84 0.130 0.156 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -22.40 0.00051
OFFICE 3242.00 3890.40 0.146 0.175 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 18:45:00 -22.40 0.00051
G NE APARTMENT 2891.26 3469.52 0.130 0.156 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -22.40 0.00051
G N1 APARTMENT 1979.82 2375.79 0.089 0.107 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -22.40 0.00051
G N2 APARTMENT 1979.73 2375.67 0.089 0.107 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -22.40 0.00051
G S1 APARTMENT 1976.58 2371.89 0.089 0.107 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -22.40 0.00051
G S2 APARTMENT 1981.79 2378.15 0.089 0.107 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -22.40 0.00051
F2 SW APARTMENT 2762.90 3315.48 0.124 0.149 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F2 NW APARTMENT 2757.34 3308.81 0.124 0.149 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F2 SE APARTMENT 2775.14 3330.17 0.125 0.150 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F2 NE APARTMENT 2754.28 3305.13 0.124 0.149 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F2 N1 APARTMENT 1625.50 1950.60 0.073 0.088 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F2 N2 APARTMENT 1625.43 1950.52 0.073 0.088 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F2 S1 APARTMENT 1633.68 1960.42 0.074 0.088 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F2 S2 APARTMENT 1634.55 1961.46 0.074 0.088 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F3 SW APARTMENT 2806.40 3367.68 0.126 0.152 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F3 NW APARTMENT 2805.37 3366.44 0.126 0.152 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F3 SE APARTMENT 2806.63 3367.96 0.126 0.152 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F3 NE APARTMENT 2804.04 3364.85 0.126 0.152 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F3 N1 APARTMENT 1608.79 1930.54 0.072 0.087 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F3 N2 APARTMENT 1608.76 1930.51 0.072 0.087 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F3 S1 APARTMENT 1610.80 1932.96 0.073 0.087 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F3 S2 APARTMENT 1610.91 1933.09 0.073 0.087 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F4 SW APARTMENT 2909.47 3491.37 0.131 0.157 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F4 NW APARTMENT 2911.33 3493.60 0.131 0.157 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F4 SE APARTMENT 2909.72 3491.66 0.131 0.157 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F4 NE APARTMENT 2911.43 3493.72 0.131 0.157 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F4 N1 APARTMENT 1662.72 1995.27 0.075 0.090 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F4 N2 APARTMENT 1662.72 1995.27 0.075 0.090 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F4 S1 APARTMENT 1661.60 1993.92 0.075 0.090 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F4 S2 APARTMENT 1661.62 1993.94 0.075 0.090 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
M SW APARTMENT 2988.08 3585.70 0.135 0.161 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
M NW APARTMENT 2991.09 3589.31 0.135 0.162 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
M SE APARTMENT 2989.39 3587.27 0.135 0.162 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
M NE APARTMENT 2992.39 3590.87 0.135 0.162 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
M N1 APARTMENT 1700.94 2041.12 0.077 0.092 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
M N2 APARTMENT 1700.97 2041.16 0.077 0.092 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
M S1 APARTMENT 1698.58 2038.29 0.076 0.092 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
M S2 APARTMENT 1698.61 2038.33 0.076 0.092 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F6 SW APARTMENT 3109.99 3731.98 0.140 0.168 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F6 NW APARTMENT 3115.39 3738.47 0.140 0.168 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F6 SE APARTMENT 3112.32 3734.78 0.140 0.168 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F6 NE APARTMENT 3117.72 3741.27 0.140 0.168 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F6 N1 APARTMENT 1787.91 2145.49 0.081 0.097 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F6 N2 APARTMENT 1787.96 2145.55 0.081 0.097 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F6 S1 APARTMENT 1783.15 2139.78 0.080 0.096 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F6 S2 APARTMENT 1783.20 2139.85 0.080 0.096 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F7 SW APARTMENT 3203.55 3844.26 0.144 0.173 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F7 NW APARTMENT 3210.18 3852.21 0.145 0.173 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F7 SE APARTMENT 3206.79 3848.15 0.144 0.173 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F7 NE APARTMENT 3213.42 3856.10 0.145 0.174 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F7 N1 APARTMENT 1850.77 2220.93 0.083 0.100 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F7 N2 APARTMENT 1850.85 2221.02 0.083 0.100 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F7 S1 APARTMENT 1844.79 2213.75 0.083 0.100 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F7 S2 APARTMENT 1844.86 2213.83 0.083 0.100 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F8 SW APARTMENT 3299.78 3959.73 0.149 0.178 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F8 NW APARTMENT 3307.19 3968.63 0.149 0.179 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F8 SE APARTMENT 3303.83 3964.59 0.149 0.178 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F8 NE APARTMENT 3311.24 3973.49 0.149 0.179 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F8 N1 APARTMENT 1919.36 2303.24 0.086 0.104 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F8 N2 APARTMENT 1919.45 2303.35 0.086 0.104 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F8 S1 APARTMENT 1912.59 2295.10 0.086 0.103 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F8 S2 APARTMENT 1912.68 2295.21 0.086 0.103 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F9 SW APARTMENT 3533.31 4239.97 0.159 0.191 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F9 NW APARTMENT 3538.77 4246.53 0.159 0.191 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F9 SE APARTMENT 3538.13 4245.76 0.159 0.191 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F9 NE APARTMENT 3543.60 4252.32 0.160 0.191 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F9 N1 APARTMENT 2116.12 2539.35 0.095 0.114 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F9 N2 APARTMENT 2116.23 2539.48 0.095 0.114 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F9 S1 APARTMENT 2110.92 2533.10 0.095 0.114 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
F9 S2 APARTMENT 2111.02 2533.23 0.095 0.114 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
T SW APARTMENT 4317.41 5180.90 0.194 0.233 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
T NW APARTMENT 4330.43 5196.52 0.195 0.234 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
T SE APARTMENT 4322.48 5186.98 0.195 0.234 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
T NE APARTMENT 4335.50 5202.60 0.195 0.234 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
T N1 APARTMENT 2943.22 3531.87 0.133 0.159 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
T N2 APARTMENT 2943.35 3532.01 0.133 0.159 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
T S1 APARTMENT 2927.86 3513.43 0.132 0.158 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051
T S2 APARTMENT 2927.98 3513.57 0.132 0.158 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 -22.40 0.00051


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
AIRLOOP G SW 0.21 0.21 0.16 0.16
AIRLOOP G NW 0.19 0.19 0.16 0.16
AIRLOOP OFFICE 0.33 0.33 0.18 0.18
AIRLOOP G NE 0.14 0.14 0.16 0.16
AIRLOOP G N1 0.09 0.09 0.11 0.11
AIRLOOP G N2 0.09 0.09 0.11 0.11
AIRLOOP G S1 0.13 0.13 0.11 0.11
AIRLOOP G S2 0.14 0.14 0.11 0.11
AIRLOOP F2 SW 0.27 0.27 0.15 0.15
AIRLOOP F2 NW 0.25 0.25 0.15 0.15
AIRLOOP F2 SE 0.27 0.27 0.15 0.15
AIRLOOP F2 NE 0.19 0.19 0.15 0.15
AIRLOOP F2 N1 0.13 0.13 0.09 0.09
AIRLOOP F2 N2 0.13 0.13 0.09 0.09
AIRLOOP F2 S1 0.18 0.18 0.09 0.09
AIRLOOP F2 S2 0.18 0.18 0.09 0.09
AIRLOOP F3 SW 0.28 0.28 0.15 0.15
AIRLOOP F3 NW 0.25 0.25 0.15 0.15
AIRLOOP F3 SE 0.25 0.25 0.15 0.15
AIRLOOP F3 NE 0.19 0.19 0.15 0.15
AIRLOOP F3 N1 0.14 0.14 0.09 0.09
AIRLOOP F3 N2 0.13 0.13 0.09 0.09
AIRLOOP F3 S1 0.18 0.18 0.09 0.09
AIRLOOP F3 S2 0.19 0.19 0.09 0.09
AIRLOOP F4 SW 0.28 0.28 0.16 0.16
AIRLOOP F4 NW 0.25 0.25 0.16 0.16
AIRLOOP F4 SE 0.25 0.25 0.16 0.16
AIRLOOP F4 NE 0.19 0.19 0.16 0.16
AIRLOOP F4 N1 0.14 0.14 0.09 0.09
AIRLOOP F4 N2 0.14 0.14 0.09 0.09
AIRLOOP F4 S1 0.19 0.19 0.09 0.09
AIRLOOP F4 S2 0.19 0.19 0.09 0.09
AIRLOOP M SW 0.28 0.28 0.16 0.16
AIRLOOP M NW 0.26 0.26 0.16 0.16
AIRLOOP M SE 0.26 0.26 0.16 0.16
AIRLOOP M NE 0.19 0.19 0.16 0.16
AIRLOOP M N1 0.14 0.14 0.09 0.09
AIRLOOP M N2 0.14 0.14 0.09 0.09
AIRLOOP M S1 0.19 0.19 0.09 0.09
AIRLOOP M S2 0.19 0.19 0.09 0.09
AIRLOOP F6 SW 0.28 0.28 0.17 0.17
AIRLOOP F6 NW 0.25 0.25 0.17 0.17
AIRLOOP F6 SE 0.25 0.25 0.17 0.17
AIRLOOP F6 NE 0.19 0.19 0.17 0.17
AIRLOOP F6 N1 0.14 0.14 0.10 0.10
AIRLOOP F6 N2 0.14 0.14 0.10 0.10
AIRLOOP F6 S1 0.19 0.19 0.10 0.10
AIRLOOP F6 S2 0.19 0.19 0.10 0.10
AIRLOOP F7 SW 0.28 0.28 0.17 0.17
AIRLOOP F7 NW 0.25 0.25 0.17 0.17
AIRLOOP F7 SE 0.25 0.25 0.17 0.17
AIRLOOP F7 NE 0.19 0.19 0.17 0.17
AIRLOOP F7 N1 0.14 0.14 0.10 0.10
AIRLOOP F7 N2 0.14 0.14 0.10 0.10
AIRLOOP F7 S1 0.19 0.19 0.10 0.10
AIRLOOP F7 S2 0.19 0.19 0.10 0.10
AIRLOOP F8 SW 0.28 0.28 0.18 0.18
AIRLOOP F8 NW 0.25 0.25 0.18 0.18
AIRLOOP F8 SE 0.25 0.25 0.18 0.18
AIRLOOP F8 NE 0.19 0.19 0.18 0.18
AIRLOOP F8 N1 0.14 0.14 0.10 0.10
AIRLOOP F8 N2 0.14 0.14 0.10 0.10
AIRLOOP F8 S1 0.19 0.19 0.10 0.10
AIRLOOP F8 S2 0.19 0.19 0.10 0.10
AIRLOOP F9 SW 0.29 0.29 0.19 0.19
AIRLOOP F9 NW 0.26 0.26 0.19 0.19
AIRLOOP F9 SE 0.26 0.26 0.19 0.19
AIRLOOP F9 NE 0.19 0.19 0.19 0.19
AIRLOOP F9 N1 0.15 0.15 0.11 0.11
AIRLOOP F9 N2 0.14 0.14 0.11 0.11
AIRLOOP F9 S1 0.19 0.19 0.11 0.11
AIRLOOP F9 S2 0.19 0.19 0.11 0.11
AIRLOOP T SW 0.36 0.36 0.23 0.23
AIRLOOP T NW 0.32 0.32 0.23 0.23
AIRLOOP T SE 0.32 0.32 0.23 0.23
AIRLOOP T NE 0.24 0.24 0.23 0.23
AIRLOOP T N1 0.19 0.19 0.16 0.16
AIRLOOP T N2 0.19 0.19 0.16 0.16
AIRLOOP T S1 0.26 0.26 0.16 0.16
AIRLOOP T S2 0.26 0.26 0.16 0.16



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 3334.25 6705.25 1880.75
G NW APARTMENT 3739.00 7082.75 2542.75
OFFICE 926.75 1131.25 114.75
G NE APARTMENT 3773.00 7085.25 2538.75
G N1 APARTMENT 2724.50 7334.00 1798.00
G N2 APARTMENT 2730.25 7332.00 1798.50
G S1 APARTMENT 2471.25 6880.75 1201.50
G S2 APARTMENT 2486.25 6798.75 1162.25
F2 SW APARTMENT 3212.00 5713.75 1033.50
F2 NW APARTMENT 3439.75 6351.75 1551.75
F2 SE APARTMENT 3308.75 5406.00 901.00
F2 NE APARTMENT 3440.00 6412.50 1570.50
F2 N1 APARTMENT 2519.25 6608.25 900.75
F2 N2 APARTMENT 2518.25 6613.50 902.50
F2 S1 APARTMENT 2604.75 5786.75 574.50
F2 S2 APARTMENT 2628.25 5735.25 569.25
F3 SW APARTMENT 3226.25 5529.25 958.50
F3 NW APARTMENT 3425.50 6226.00 1460.25
F3 SE APARTMENT 3273.50 5477.00 937.25
F3 NE APARTMENT 3416.00 6279.75 1474.75
F3 N1 APARTMENT 2527.75 6441.25 790.50
F3 N2 APARTMENT 2523.50 6451.00 790.25
F3 S1 APARTMENT 2724.75 5475.25 522.50
F3 S2 APARTMENT 2733.00 5454.25 520.50
F4 SW APARTMENT 3256.00 5517.75 977.25
F4 NW APARTMENT 3461.75 6197.50 1487.25
F4 SE APARTMENT 3280.25 5519.50 970.75
F4 NE APARTMENT 3442.25 6262.00 1502.50
F4 N1 APARTMENT 2563.50 6374.50 793.00
F4 N2 APARTMENT 2558.00 6383.75 791.25
F4 S1 APARTMENT 2762.00 5401.25 517.75
F4 S2 APARTMENT 2766.25 5393.75 518.50
M SW APARTMENT 3239.00 5556.25 975.25
M NW APARTMENT 3452.75 6208.50 1480.00
M SE APARTMENT 3256.50 5560.00 968.00
M NE APARTMENT 3427.00 6281.25 1492.00
M N1 APARTMENT 2564.50 6361.50 777.75
M N2 APARTMENT 2557.25 6371.75 776.25
M S1 APARTMENT 2753.00 5416.00 511.00
M S2 APARTMENT 2755.00 5413.75 511.75
F6 SW APARTMENT 3204.75 5735.25 1056.75
F6 NW APARTMENT 3471.00 6349.75 1601.50
F6 SE APARTMENT 3226.25 5750.75 1050.00
F6 NE APARTMENT 3462.25 6419.00 1623.25
F6 N1 APARTMENT 2547.00 6498.25 870.25
F6 N2 APARTMENT 2545.50 6507.25 871.00
F6 S1 APARTMENT 2653.25 5615.25 554.25
F6 S2 APARTMENT 2655.00 5615.75 553.75
F7 SW APARTMENT 3178.50 5872.25 1112.00
F7 NW APARTMENT 3486.25 6432.00 1682.00
F7 SE APARTMENT 3204.75 5880.75 1107.00
F7 NE APARTMENT 3479.75 6515.75 1702.50
F7 N1 APARTMENT 2540.00 6586.75 923.75
F7 N2 APARTMENT 2538.00 6596.00 925.00
F7 S1 APARTMENT 2594.00 5762.00 579.00
F7 S2 APARTMENT 2594.50 5757.75 579.25
F8 SW APARTMENT 3168.25 5997.50 1166.00
F8 NW APARTMENT 3512.75 6504.00 1762.75
F8 SE APARTMENT 3200.25 5991.50 1170.25
F8 NE APARTMENT 3509.75 6592.50 1778.50
F8 N1 APARTMENT 2543.75 6652.75 975.50
F8 N2 APARTMENT 2539.25 6665.25 977.25
F8 S1 APARTMENT 2548.25 5888.00 604.00
F8 S2 APARTMENT 2548.00 5886.00 603.75
F9 SW APARTMENT 3301.50 6097.50 1360.00
F9 NW APARTMENT 3684.25 6551.25 1984.50
F9 SE APARTMENT 3327.75 6091.50 1359.00
F9 NE APARTMENT 3697.25 6648.25 2006.25
F9 N1 APARTMENT 2663.00 6720.50 1128.75
F9 N2 APARTMENT 2660.50 6737.50 1131.00
F9 S1 APARTMENT 2595.00 6045.50 727.25
F9 S2 APARTMENT 2598.00 6046.25 728.00
T SW APARTMENT 4297.50 6285.50 2485.25
T NW APARTMENT 4564.50 6759.50 3044.50
T SE APARTMENT 4357.50 6309.00 2504.25
T NE APARTMENT 4575.75 6842.75 3070.25
T N1 APARTMENT 3761.75 6902.00 2367.00
T N2 APARTMENT 3761.00 6909.75 2368.25
T S1 APARTMENT 3518.25 6215.00 1752.50
T S2 APARTMENT 3530.00 6213.25 1753.00
G CORRIDOR 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00
Facility 5789.75 7507.25 3353.75
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 3.50 7.00 3.50 7.00
G NW APARTMENT 1.00 8.75 1.00 8.75
OFFICE 3.00 0.00 0.50 0.00
G NE APARTMENT 4.00 6.00 4.00 6.00
G N1 APARTMENT 5.25 13.75 5.25 13.75
G N2 APARTMENT 5.50 12.75 5.50 12.75
G S1 APARTMENT 2.75 20.25 2.75 20.25
G S2 APARTMENT 2.75 18.75 2.75 18.75
F2 SW APARTMENT 1.50 7.50 1.50 7.50
F2 NW APARTMENT 1.75 7.75 1.75 7.75
F2 SE APARTMENT 1.50 6.00 1.50 6.00
F2 NE APARTMENT 1.75 50.50 1.75 50.50
F2 N1 APARTMENT 1.50 42.25 1.50 42.25
F2 N2 APARTMENT 3.00 43.75 3.00 43.75
F2 S1 APARTMENT 2.75 18.75 2.75 18.75
F2 S2 APARTMENT 2.75 17.75 2.75 17.75
F3 SW APARTMENT 0.25 10.25 0.25 10.25
F3 NW APARTMENT 0.50 10.00 0.50 10.00
F3 SE APARTMENT 1.00 20.75 1.00 20.75
F3 NE APARTMENT 0.75 61.75 0.75 61.75
F3 N1 APARTMENT 2.25 56.50 2.25 56.50
F3 N2 APARTMENT 4.50 63.25 4.50 63.25
F3 S1 APARTMENT 5.75 29.00 5.75 29.00
F3 S2 APARTMENT 5.00 28.00 5.00 28.00
F4 SW APARTMENT 1.00 11.25 1.00 11.25
F4 NW APARTMENT 0.25 11.50 0.25 11.50
F4 SE APARTMENT 0.00 23.50 0.00 23.50
F4 NE APARTMENT 1.50 66.00 1.50 66.00
F4 N1 APARTMENT 4.25 59.25 4.25 59.25
F4 N2 APARTMENT 4.25 67.75 4.25 67.75
F4 S1 APARTMENT 3.75 31.50 3.75 31.50
F4 S2 APARTMENT 2.50 30.25 2.50 30.25
M SW APARTMENT 1.25 12.25 1.25 12.25
M NW APARTMENT 1.25 12.25 1.25 12.25
M SE APARTMENT 1.00 24.75 1.00 24.75
M NE APARTMENT 1.50 68.50 1.50 68.50
M N1 APARTMENT 2.75 61.00 2.75 61.00
M N2 APARTMENT 3.50 70.00 3.50 70.00
M S1 APARTMENT 2.50 33.50 2.50 33.50
M S2 APARTMENT 2.00 33.50 2.00 33.50
F6 SW APARTMENT 1.25 12.25 1.25 12.25
F6 NW APARTMENT 1.25 13.75 1.25 13.75
F6 SE APARTMENT 0.50 25.00 0.50 25.00
F6 NE APARTMENT 1.25 69.50 1.25 69.50
F6 N1 APARTMENT 2.75 62.25 2.75 62.25
F6 N2 APARTMENT 3.25 71.75 3.25 71.75
F6 S1 APARTMENT 3.25 34.25 3.25 34.25
F6 S2 APARTMENT 3.50 33.50 3.50 33.50
F7 SW APARTMENT 1.00 13.25 1.00 13.25
F7 NW APARTMENT 0.75 14.25 0.75 14.25
F7 SE APARTMENT 1.00 25.00 1.00 25.00
F7 NE APARTMENT 1.75 70.50 1.75 70.50
F7 N1 APARTMENT 1.75 63.50 1.75 63.50
F7 N2 APARTMENT 2.75 73.25 2.75 73.25
F7 S1 APARTMENT 2.75 34.25 2.75 34.25
F7 S2 APARTMENT 3.00 34.50 3.00 34.50
F8 SW APARTMENT 0.75 13.25 0.75 13.25
F8 NW APARTMENT 0.50 15.00 0.50 15.00
F8 SE APARTMENT 1.75 25.50 1.75 25.50
F8 NE APARTMENT 1.50 72.00 1.50 72.00
F8 N1 APARTMENT 1.00 64.25 1.00 64.25
F8 N2 APARTMENT 2.00 72.50 2.00 72.50
F8 S1 APARTMENT 2.50 35.25 2.50 35.25
F8 S2 APARTMENT 3.00 35.00 3.00 35.00
F9 SW APARTMENT 0.50 13.50 0.50 13.50
F9 NW APARTMENT 0.50 13.75 0.50 13.75
F9 SE APARTMENT 0.25 24.25 0.25 24.25
F9 NE APARTMENT 1.00 73.75 1.00 73.75
F9 N1 APARTMENT 1.75 57.50 1.75 57.50
F9 N2 APARTMENT 3.25 63.25 3.25 63.25
F9 S1 APARTMENT 3.00 34.75 3.00 34.75
F9 S2 APARTMENT 2.75 34.50 2.75 34.50
T SW APARTMENT 0.00 8.50 0.00 8.50
T NW APARTMENT 0.00 12.25 0.00 12.25
T SE APARTMENT 0.50 19.50 0.50 19.50
T NE APARTMENT 0.00 49.00 0.00 49.00
T N1 APARTMENT 0.75 41.50 0.75 41.50
T N2 APARTMENT 1.00 44.50 1.00 44.50
T S1 APARTMENT 0.75 17.75 0.75 17.75
T S2 APARTMENT 0.75 17.50 0.75 17.50
G CORRIDOR 0.00 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
Facility 122.75 100.50 120.25 100.50
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.354 0.192 0.000 0.308
G NW APARTMENT 1.71 2.50 268.96 0.354 0.192 0.000 0.281
OFFICE 0.94 1.00 268.96 0.519 0.220 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.354 0.192 0.000 0.282
G N1 APARTMENT 1.71 2.50 268.96 0.354 0.116 0.000 0.275
G N2 APARTMENT 1.71 2.50 268.97 0.354 0.116 0.000 0.275
G S1 APARTMENT 1.71 2.50 268.96 0.354 0.116 0.000 0.304
G S2 APARTMENT 1.71 2.50 268.97 0.354 0.116 0.000 0.305
F2 SW APARTMENT 1.71 2.50 268.96 0.354 0.276 0.000 0.363
F2 NW APARTMENT 1.71 2.50 268.96 0.354 0.276 0.000 0.322
F2 SE APARTMENT 1.71 2.50 268.96 0.354 0.276 0.000 0.366
F2 NE APARTMENT 1.71 2.50 268.96 0.354 0.276 0.000 0.322
F2 N1 APARTMENT 1.71 2.50 268.96 0.354 0.166 0.000 0.317
F2 N2 APARTMENT 1.71 2.50 268.97 0.354 0.166 0.000 0.317
F2 S1 APARTMENT 1.71 2.50 268.96 0.354 0.167 0.000 0.361
F2 S2 APARTMENT 1.71 2.50 268.97 0.354 0.167 0.000 0.361
F3 SW APARTMENT 1.71 2.50 268.96 0.354 0.327 0.000 0.402
F3 NW APARTMENT 1.71 2.50 268.96 0.354 0.327 0.000 0.350
F3 SE APARTMENT 1.71 2.50 268.96 0.354 0.327 0.000 0.403
F3 NE APARTMENT 1.71 2.50 268.96 0.354 0.327 0.000 0.350
F3 N1 APARTMENT 1.71 2.50 268.96 0.354 0.197 0.000 0.346
F3 N2 APARTMENT 1.71 2.50 268.97 0.354 0.197 0.000 0.346
F3 S1 APARTMENT 1.71 2.50 268.96 0.354 0.197 0.000 0.400
F3 S2 APARTMENT 1.71 2.50 268.97 0.354 0.197 0.000 0.400
F4 SW APARTMENT 1.71 2.50 268.96 0.354 0.365 0.000 0.415
F4 NW APARTMENT 1.71 2.50 268.96 0.354 0.365 0.000 0.358
F4 SE APARTMENT 1.71 2.50 268.96 0.354 0.365 0.000 0.416
F4 NE APARTMENT 1.71 2.50 268.96 0.354 0.365 0.000 0.358
F4 N1 APARTMENT 1.71 2.50 268.96 0.354 0.220 0.000 0.354
F4 N2 APARTMENT 1.71 2.50 268.97 0.354 0.220 0.000 0.354
F4 S1 APARTMENT 1.71 2.50 268.96 0.354 0.220 0.000 0.414
F4 S2 APARTMENT 1.71 2.50 268.97 0.354 0.220 0.000 0.414
M SW APARTMENT 1.71 2.50 268.96 0.354 0.397 0.000 0.437
M NW APARTMENT 1.71 2.50 268.96 0.354 0.397 0.000 0.373
M SE APARTMENT 1.71 2.50 268.96 0.354 0.397 0.000 0.437
M NE APARTMENT 1.71 2.50 268.96 0.354 0.397 0.000 0.373
M N1 APARTMENT 1.71 2.50 268.96 0.354 0.239 0.000 0.370
M N2 APARTMENT 1.71 2.50 268.97 0.354 0.239 0.000 0.370
M S1 APARTMENT 1.71 2.50 268.96 0.354 0.239 0.000 0.435
M S2 APARTMENT 1.71 2.50 268.97 0.354 0.239 0.000 0.435
F6 SW APARTMENT 1.71 2.50 268.96 0.354 0.424 0.000 0.455
F6 NW APARTMENT 1.71 2.50 268.96 0.354 0.424 0.000 0.386
F6 SE APARTMENT 1.71 2.50 268.96 0.354 0.424 0.000 0.455
F6 NE APARTMENT 1.71 2.50 268.96 0.353 0.424 0.000 0.386
F6 N1 APARTMENT 1.71 2.50 268.96 0.354 0.256 0.000 0.382
F6 N2 APARTMENT 1.71 2.50 268.97 0.354 0.256 0.000 0.382
F6 S1 APARTMENT 1.71 2.50 268.96 0.354 0.256 0.000 0.453
F6 S2 APARTMENT 1.71 2.50 268.97 0.354 0.256 0.000 0.453
F7 SW APARTMENT 1.71 2.50 268.96 0.354 0.448 0.000 0.470
F7 NW APARTMENT 1.71 2.50 268.96 0.353 0.448 0.000 0.397
F7 SE APARTMENT 1.71 2.50 268.96 0.354 0.448 0.000 0.471
F7 NE APARTMENT 1.71 2.50 268.96 0.353 0.448 0.000 0.397
F7 N1 APARTMENT 1.71 2.50 268.96 0.354 0.270 0.000 0.393
F7 N2 APARTMENT 1.71 2.50 268.97 0.354 0.270 0.000 0.393
F7 S1 APARTMENT 1.71 2.50 268.96 0.354 0.270 0.000 0.468
F7 S2 APARTMENT 1.71 2.50 268.97 0.354 0.270 0.000 0.468
F8 SW APARTMENT 1.71 2.50 268.96 0.354 0.470 0.000 0.485
F8 NW APARTMENT 1.71 2.50 268.96 0.353 0.469 0.000 0.408
F8 SE APARTMENT 1.71 2.50 268.96 0.354 0.470 0.000 0.486
F8 NE APARTMENT 1.71 2.50 268.96 0.353 0.469 0.000 0.408
F8 N1 APARTMENT 1.71 2.50 268.96 0.354 0.283 0.000 0.404
F8 N2 APARTMENT 1.71 2.50 268.97 0.354 0.283 0.000 0.404
F8 S1 APARTMENT 1.71 2.50 268.96 0.354 0.283 0.000 0.483
F8 S2 APARTMENT 1.71 2.50 268.97 0.354 0.283 0.000 0.483
F9 SW APARTMENT 1.71 2.50 268.96 0.354 0.490 0.000 0.500
F9 NW APARTMENT 1.71 2.50 268.96 0.353 0.489 0.000 0.419
F9 SE APARTMENT 1.71 2.50 268.96 0.354 0.489 0.000 0.501
F9 NE APARTMENT 1.71 2.50 268.96 0.353 0.489 0.000 0.419
F9 N1 APARTMENT 1.71 2.50 268.96 0.354 0.295 0.000 0.415
F9 N2 APARTMENT 1.71 2.50 268.97 0.354 0.295 0.000 0.415
F9 S1 APARTMENT 1.71 2.50 268.96 0.354 0.295 0.000 0.498
F9 S2 APARTMENT 1.71 2.50 268.97 0.354 0.295 0.000 0.498
T SW APARTMENT 1.71 2.50 268.96 0.354 0.508 0.000 0.511
T NW APARTMENT 1.71 2.50 268.96 0.353 0.507 0.000 0.427
T SE APARTMENT 1.71 2.50 268.96 0.353 0.508 0.000 0.511
T NE APARTMENT 1.71 2.50 268.96 0.353 0.507 0.000 0.427
T N1 APARTMENT 1.71 2.50 268.96 0.353 0.306 0.000 0.424
T N2 APARTMENT 1.71 2.50 268.97 0.353 0.306 0.000 0.424
T S1 APARTMENT 1.71 2.50 268.96 0.354 0.306 0.000 0.509
T S2 APARTMENT 1.71 2.50 268.97 0.354 0.306 0.000 0.510
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
OFFICE 0.94 1.00 268.96 0.500 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F2 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F2 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F3 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F3 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F4 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F4 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F6 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F6 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F7 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F7 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F8 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F8 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F9 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F9 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Surfaces by Class

Total Outdoors
Wall 420 140
Floor 90 9
Roof 90 9
Internal Mass 80 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 140 140
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 80
Conditioned Zones 80
Unconditioned Zones 10
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 4156
Defaulted Fields 814
Fields with Defaults 11184
Autosized Fields 1293
Autosizable Fields 1630
Autocalculated Fields 907
Autocalculatable Fields 1710



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 2945.25 53915.77 24-JUN-04:15 189762.54 07-FEB-18:00
Electricity:Building 1433.88 25760.85 01-JAN-03:15 70162.48 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity 296.56 6715.87 01-JAN-00:15 14401.37 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 242.55 5824.91 01-JAN-00:15 11484.27 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:OFFICE 39.38 663.42 01-JAN-00:15 2934.49 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 29.88 469.18 01-JAN-00:15 2345.88 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:G CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F2 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F2 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F3 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F3 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F4 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F4 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:M SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M CORRIDOR 32.88 1042.61 01-JAN-00:15 1042.61 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 32.88 1042.61 01-JAN-00:15 1042.61 01-JAN-00:15
Electricity:Zone:F6 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F6 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F7 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F7 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F8 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F8 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F9 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F9 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:T SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T CORRIDOR 179.47 1701.70 01-JAN-00:15 10868.20 01-JAN-07:15
InteriorLights:Electricity:Zone:T CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 54.01 890.97 01-JAN-00:15 2917.11 01-JAN-19:15
InteriorEquipment:Electricity 1137.32 19044.98 01-JAN-03:15 57142.09 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 1137.32 19044.98 01-JAN-03:15 57142.09 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 9.50 194.24 01-JAN-00:15 588.62 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T CORRIDOR 163.03 1180.40 01-JAN-00:15 10346.90 01-JAN-07:15
Fans:Electricity 605.54 19201.55 01-JAN-00:15 19201.55 01-JAN-00:15
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Electricity:HVAC 1274.21 19862.80 06-MAY-02:15 119522.29 07-FEB-02:00
ElectricityProduced:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityProduced:HVAC 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricityProduced 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 2945.25 53915.77 24-JUN-04:15 189762.54 07-FEB-18:00
ElectricityPurchased:Plant 2945.25 53915.77 24-JUN-04:15 189762.54 07-FEB-18:00
Cogeneration:ElectricityPurchased 2945.25 53915.77 24-JUN-04:15 189762.54 07-FEB-18:00
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 2945.25 53915.77 24-JUN-04:15 189762.54 07-FEB-18:00
ElectricityNet:Plant 2945.25 53915.77 24-JUN-04:15 189762.54 07-FEB-18:00
Cogeneration:ElectricityNet 2945.25 53915.77 24-JUN-04:15 189762.54 07-FEB-18:00
ExteriorLights:Electricity 162.69 0.00 01-JAN-07:45 10364.00 01-JAN-00:15
General:ExteriorLights:Electricity 162.69 0.00 01-JAN-07:45 10364.00 01-JAN-00:15
General:Fans:Electricity 605.54 19201.55 01-JAN-00:15 19201.55 01-JAN-00:15
Cooling:Electricity 230.30 0.00 01-JAN-00:15 77321.23 16-JUN-14:15
Heating:Electricity 402.19 0.00 28-MAR-16:15 99626.45 07-FEB-02:00
Electricity:Plant 74.46 36.93 11-APR-18:30 5168.12 16-JUN-10:15
HeatRejection:Electricity 10.13 0.00 01-JAN-00:15 3088.25 16-JUN-10:15
Boiler Parasitic:Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Pumps:Electricity 64.33 36.93 11-APR-18:30 2079.88 01-JAN-00:15
WIRED_LTG_ELECTRICITY 0.44 0.00 01-JAN-00:15 21.60 01-JAN-19:30
WIRED_INT_EQUIP 979.40 1018.50 01-JAN-00:15 10185.00 01-JAN-07:15


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 2799.92 2357.00 17-MAR-23:30 372607.72 24-JAN-07:30
Gas:Plant 2799.92 2357.00 17-MAR-23:30 372607.72 24-JAN-07:30
WaterSystems:Gas 1241.86 2357.00 01-JAN-00:15 85459.07 18-FEB-08:00
Water Heater:WaterSystems:Gas 1241.86 2357.00 01-JAN-00:15 85459.07 18-FEB-08:00
Heating:Gas 1558.07 0.00 17-MAR-11:45 295852.49 27-JAN-07:15
Boiler:Heating:Gas 1558.07 0.00 17-MAR-11:45 295852.49 27-JAN-07:15


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
PlantLoopCoolingDemand:Facility 972.24 0.00 01-JAN-00:15 381335.90 04-AUG-15:30
PlantLoopCoolingDemand:HVAC 972.24 0.00 01-JAN-00:15 381335.90 04-AUG-15:30
CoolingCoils:PlantLoopCoolingDemand 972.24 0.00 01-JAN-00:15 381335.90 04-AUG-15:30


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 5471.28 0.00 01-JAN-02:15 0.00 20-JUL-17:15
Water:Plant 5471.28 0.00 01-JAN-02:15 0.00 20-JUL-17:15
WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
MainsWater:Facility 5471.28 0.00 01-JAN-02:15 0.00 20-JUL-17:15
MainsWater:Plant 5471.28 0.00 01-JAN-02:15 0.00 20-JUL-17:15
WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
sub cat:WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
sub cat:WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
HeatRejection:Water 692.77 0.00 01-JAN-00:15 0.00 20-JUL-16:00
HeatRejection:MainsWater 692.77 0.00 01-JAN-00:15 0.00 20-JUL-16:00


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 2178.07 503.62 11-AUG-01:15 288976.62 27-JAN-07:15
PlantLoopHeatingDemand:Plant 967.69 503.62 11-AUG-01:15 65723.37 19-FEB-07:30
WaterSystems:PlantLoopHeatingDemand 967.69 503.62 11-AUG-01:15 65723.37 19-FEB-07:30
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 6107.63 4973.91 27-SEP-03:00 815780.51 17-DEC-08:30
EnergyTransfer:Building 1634.86 3012.22 27-MAY-13:30 252506.43 07-MAR-14:00
EnergyTransfer:Zone:G SW APARTMENT 18.03 0.10 12-AUG-14:45 2638.98 17-DEC-08:30
Heating:EnergyTransfer 1037.82 0.00 17-MAR-15:15 252506.43 07-MAR-14:00
Heating:EnergyTransfer:Zone:G SW APARTMENT 12.23 0.00 01-JAN-11:30 2638.98 17-DEC-08:30
Cooling:EnergyTransfer 597.04 0.00 01-JAN-00:15 179906.83 29-JUL-16:15
Cooling:EnergyTransfer:Zone:G SW APARTMENT 5.80 0.00 01-JAN-00:15 2540.47 13-SEP-15:15
EnergyTransfer:Zone:G NW APARTMENT 19.70 0.18 31-AUG-08:30 3010.13 27-JAN-08:15
Heating:EnergyTransfer:Zone:G NW APARTMENT 15.59 0.00 18-FEB-15:00 3010.13 27-JAN-08:15
Cooling:EnergyTransfer:Zone:G NW APARTMENT 4.11 0.00 01-JAN-00:15 2162.61 05-JUL-17:30
EnergyTransfer:Zone:OFFICE 23.39 0.02 04-OCT-02:00 3517.62 20-JUL-13:00
Heating:EnergyTransfer:Zone:OFFICE 9.31 0.00 01-JAN-11:30 2656.40 17-DEC-08:30
Cooling:EnergyTransfer:Zone:OFFICE 14.08 0.00 01-JAN-00:15 3517.62 20-JUL-13:00
EnergyTransfer:Zone:G NE APARTMENT 19.37 0.00 25-OCT-13:00 2769.58 07-FEB-18:00
Heating:EnergyTransfer:Zone:G NE APARTMENT 15.36 0.00 17-MAR-08:00 2769.58 07-FEB-18:00
Cooling:EnergyTransfer:Zone:G NE APARTMENT 4.01 0.00 01-JAN-00:15 1632.63 15-JUL-09:15
EnergyTransfer:Zone:G N1 APARTMENT 12.64 0.03 28-APR-13:30 2033.85 27-JAN-08:15
Heating:EnergyTransfer:Zone:G N1 APARTMENT 9.13 0.00 01-FEB-19:45 2033.85 27-JAN-08:15
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 3.51 0.00 01-JAN-00:15 1284.84 01-JUL-18:30
EnergyTransfer:Zone:G N2 APARTMENT 12.63 0.03 21-AUG-06:00 2030.20 27-JAN-08:15
Heating:EnergyTransfer:Zone:G N2 APARTMENT 9.13 0.00 01-FEB-19:45 2030.20 27-JAN-08:15
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 3.50 0.00 01-JAN-00:15 1261.70 01-JUL-18:30
EnergyTransfer:Zone:G S1 APARTMENT 11.56 0.00 30-MAY-20:45 1673.07 01-AUG-13:45
Heating:EnergyTransfer:Zone:G S1 APARTMENT 5.92 0.00 01-JAN-11:00 1610.45 17-DEC-08:30
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 5.64 0.00 01-JAN-00:15 1673.07 01-AUG-13:45
EnergyTransfer:Zone:G S2 APARTMENT 11.54 0.00 03-JUN-09:30 1742.11 01-AUG-13:45
Heating:EnergyTransfer:Zone:G S2 APARTMENT 5.71 0.00 01-JAN-11:00 1602.77 17-DEC-08:30
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 5.82 0.00 01-JAN-00:15 1742.11 01-AUG-13:45
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F2 SW APARTMENT 20.93 0.01 12-MAY-09:15 3195.97 13-SEP-15:15
Heating:EnergyTransfer:Zone:F2 SW APARTMENT 11.34 0.00 01-JAN-11:15 2967.02 07-FEB-02:00
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT 9.59 0.00 01-JAN-00:15 3195.97 13-SEP-15:15
EnergyTransfer:Zone:F2 NW APARTMENT 21.99 0.01 27-APR-23:15 3258.06 07-FEB-02:00
Heating:EnergyTransfer:Zone:F2 NW APARTMENT 15.31 0.00 01-FEB-19:45 3258.06 07-FEB-02:00
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT 6.67 0.00 01-JAN-00:15 2791.95 01-JUL-18:30
EnergyTransfer:Zone:F2 SE APARTMENT 21.01 0.05 09-APR-22:00 2931.23 02-SEP-12:45
Heating:EnergyTransfer:Zone:F2 SE APARTMENT 10.42 0.00 01-JAN-11:00 2843.52 07-FEB-02:00
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT 10.59 0.00 01-JAN-00:15 2931.23 02-SEP-12:45
EnergyTransfer:Zone:F2 NE APARTMENT 21.78 0.01 23-OCT-23:00 3215.77 07-FEB-02:00
Heating:EnergyTransfer:Zone:F2 NE APARTMENT 15.06 0.00 01-FEB-19:45 3215.77 07-FEB-02:00
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT 6.72 0.00 01-JAN-00:15 2112.00 29-JUL-16:15
EnergyTransfer:Zone:F2 N1 APARTMENT 12.96 0.00 25-AUG-16:00 1877.68 07-FEB-02:00
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT 7.22 0.00 15-JAN-23:00 1877.68 07-FEB-02:00
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT 5.74 0.00 01-JAN-00:15 1731.29 01-JUL-18:30
EnergyTransfer:Zone:F2 N2 APARTMENT 12.96 0.00 04-JUN-15:15 1875.26 07-FEB-02:00
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT 7.22 0.00 15-JAN-23:00 1875.26 07-FEB-02:00
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT 5.74 0.00 01-JAN-00:15 1714.21 01-JUL-18:30
EnergyTransfer:Zone:F2 S1 APARTMENT 13.45 0.00 30-MAY-10:45 2238.03 01-AUG-13:45
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT 4.33 0.00 01-JAN-10:00 1613.66 25-JAN-05:00
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT 9.13 0.00 01-JAN-00:15 2238.03 01-AUG-13:45
EnergyTransfer:Zone:F2 S2 APARTMENT 13.51 0.04 01-JUN-11:00 2262.31 01-AUG-13:45
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT 4.29 0.00 01-JAN-10:15 1608.63 25-JAN-05:00
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT 9.22 0.00 01-JAN-00:15 2262.31 01-AUG-13:45
EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F3 SW APARTMENT 22.04 0.07 03-FEB-16:30 3254.22 13-SEP-15:15
Heating:EnergyTransfer:Zone:F3 SW APARTMENT 12.00 0.00 01-JAN-11:15 3234.12 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT 10.04 0.00 01-JAN-00:15 3254.22 13-SEP-15:15
EnergyTransfer:Zone:F3 NW APARTMENT 23.15 0.01 28-APR-01:30 3510.44 07-MAR-14:00
Heating:EnergyTransfer:Zone:F3 NW APARTMENT 16.05 0.00 01-FEB-19:45 3510.44 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT 7.10 0.00 01-JAN-00:15 2863.07 01-JUL-18:30
EnergyTransfer:Zone:F3 SE APARTMENT 21.92 0.01 11-DEC-20:15 3199.78 07-MAR-14:00
Heating:EnergyTransfer:Zone:F3 SE APARTMENT 11.75 0.00 01-JAN-11:00 3199.78 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT 10.17 0.00 01-JAN-00:15 2881.02 29-JUL-15:45
EnergyTransfer:Zone:F3 NE APARTMENT 22.93 0.05 26-JUN-12:45 3479.29 07-MAR-14:00
Heating:EnergyTransfer:Zone:F3 NE APARTMENT 15.80 0.00 01-FEB-19:45 3479.29 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT 7.12 0.00 01-JAN-00:15 2189.14 29-JUL-15:45
EnergyTransfer:Zone:F3 N1 APARTMENT 13.54 0.01 10-NOV-20:00 2007.15 07-MAR-14:00
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT 7.26 0.00 10-JAN-19:00 2007.15 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT 6.28 0.00 01-JAN-00:15 1801.63 01-JUL-18:30
EnergyTransfer:Zone:F3 N2 APARTMENT 13.54 0.01 27-NOV-17:30 2003.87 07-MAR-14:00
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT 7.26 0.00 10-JAN-19:00 2003.87 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT 6.28 0.00 01-JAN-00:15 1784.67 01-JUL-18:30
EnergyTransfer:Zone:F3 S1 APARTMENT 14.27 0.01 21-APR-06:00 2303.17 01-AUG-13:45
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT 4.41 0.00 01-JAN-09:45 1739.93 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT 9.86 0.00 01-JAN-00:15 2303.17 01-AUG-13:45
EnergyTransfer:Zone:F3 S2 APARTMENT 14.29 0.05 22-MAY-14:45 2313.89 01-AUG-13:45
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT 4.40 0.00 01-JAN-09:45 1736.43 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT 9.89 0.00 01-JAN-00:15 2313.89 01-AUG-13:45
EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F4 SW APARTMENT 22.96 0.01 25-MAR-21:30 3558.81 07-MAR-14:00
Heating:EnergyTransfer:Zone:F4 SW APARTMENT 13.03 0.00 01-JAN-11:15 3558.81 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT 9.93 0.00 01-JAN-00:15 3281.98 01-AUG-17:00
EnergyTransfer:Zone:F4 NW APARTMENT 24.27 0.03 25-SEP-19:00 3836.90 07-MAR-14:00
Heating:EnergyTransfer:Zone:F4 NW APARTMENT 17.19 0.00 01-FEB-19:45 3836.90 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT 7.08 0.00 01-JAN-00:15 2903.71 01-JUL-18:30
EnergyTransfer:Zone:F4 SE APARTMENT 22.83 0.01 04-OCT-02:30 3529.88 07-MAR-14:00
Heating:EnergyTransfer:Zone:F4 SE APARTMENT 12.89 0.00 01-JAN-11:15 3529.88 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT 9.94 0.00 01-JAN-00:15 2909.09 29-JUL-15:30
EnergyTransfer:Zone:F4 NE APARTMENT 24.05 0.01 29-OCT-15:30 3805.46 07-MAR-14:00
Heating:EnergyTransfer:Zone:F4 NE APARTMENT 16.93 0.00 01-FEB-19:45 3805.46 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT 7.12 0.00 01-JAN-00:15 2223.13 29-JUL-15:30
EnergyTransfer:Zone:F4 N1 APARTMENT 14.12 0.00 24-MAY-10:15 2194.74 07-MAR-14:00
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT 7.78 0.00 14-JAN-19:00 2194.74 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT 6.35 0.00 01-JAN-00:15 1838.46 01-JUL-18:45
EnergyTransfer:Zone:F4 N2 APARTMENT 14.12 0.00 22-AUG-20:00 2191.48 07-MAR-14:00
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT 7.78 0.00 14-JAN-19:00 2191.48 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT 6.34 0.00 01-JAN-00:15 1817.90 01-JUL-18:30
EnergyTransfer:Zone:F4 S1 APARTMENT 14.74 0.06 19-MAY-18:00 2349.63 19-AUG-13:00
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT 4.85 0.00 01-JAN-09:45 1926.27 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT 9.89 0.00 01-JAN-00:15 2349.63 19-AUG-13:00
EnergyTransfer:Zone:F4 S2 APARTMENT 14.75 0.06 14-MAR-17:15 2358.51 19-AUG-13:00
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT 4.85 0.00 01-JAN-09:45 1923.33 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT 9.90 0.00 01-JAN-00:15 2358.51 19-AUG-13:00
EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M SW APARTMENT 23.71 0.02 15-JUN-11:30 3821.03 07-MAR-14:00
Heating:EnergyTransfer:Zone:M SW APARTMENT 13.88 0.00 01-JAN-11:15 3821.03 07-MAR-14:00
Cooling:EnergyTransfer:Zone:M SW APARTMENT 9.84 0.00 01-JAN-00:15 3331.85 01-AUG-17:00
EnergyTransfer:Zone:M NW APARTMENT 25.18 0.01 28-APR-04:30 4097.68 07-MAR-14:00
Heating:EnergyTransfer:Zone:M NW APARTMENT 18.07 0.00 01-FEB-19:45 4097.68 07-MAR-14:00
Cooling:EnergyTransfer:Zone:M NW APARTMENT 7.11 0.00 01-JAN-00:15 2955.34 01-JUL-18:30
EnergyTransfer:Zone:M SE APARTMENT 23.57 0.05 14-DEC-13:45 3792.48 07-MAR-14:00
Heating:EnergyTransfer:Zone:M SE APARTMENT 13.75 0.00 01-JAN-11:15 3792.48 07-MAR-14:00
Cooling:EnergyTransfer:Zone:M SE APARTMENT 9.82 0.00 01-JAN-00:15 2952.55 29-JUL-15:30
EnergyTransfer:Zone:M NE APARTMENT 24.93 0.04 15-JUN-02:15 4066.05 07-MAR-14:00
Heating:EnergyTransfer:Zone:M NE APARTMENT 17.80 0.00 01-FEB-19:45 4066.05 07-MAR-14:00
Cooling:EnergyTransfer:Zone:M NE APARTMENT 7.13 0.00 01-JAN-00:15 2261.35 29-JUL-15:30
EnergyTransfer:Zone:M N1 APARTMENT 14.59 0.01 02-JUN-20:15 2343.18 07-MAR-14:00
Heating:EnergyTransfer:Zone:M N1 APARTMENT 8.17 0.00 14-JAN-19:00 2343.18 07-MAR-14:00
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 6.42 0.00 01-JAN-00:15 1891.15 01-JUL-18:45
EnergyTransfer:Zone:M N2 APARTMENT 14.59 0.01 13-JUN-09:45 2339.94 07-MAR-14:00
Heating:EnergyTransfer:Zone:M N2 APARTMENT 8.17 0.00 14-JAN-19:00 2339.94 07-MAR-14:00
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 6.42 0.00 01-JAN-00:15 1867.17 01-JUL-18:45
EnergyTransfer:Zone:M S1 APARTMENT 15.10 0.01 11-SEP-16:00 2400.51 19-AUG-13:00
Heating:EnergyTransfer:Zone:M S1 APARTMENT 5.22 0.00 01-JAN-09:45 2078.09 07-MAR-14:00
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 9.88 0.00 01-JAN-00:15 2400.51 19-AUG-13:00
EnergyTransfer:Zone:M S2 APARTMENT 15.10 0.01 01-JUL-05:45 2409.16 19-AUG-13:00
Heating:EnergyTransfer:Zone:M S2 APARTMENT 5.22 0.00 01-JAN-09:45 2075.30 07-MAR-14:00
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 9.88 0.00 01-JAN-00:15 2409.16 19-AUG-13:00
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F6 SW APARTMENT 24.40 0.01 13-OCT-03:45 4091.68 07-MAR-14:00
Heating:EnergyTransfer:Zone:F6 SW APARTMENT 15.23 0.00 01-JAN-11:30 4091.68 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT 9.17 0.00 01-JAN-00:15 3316.66 01-AUG-17:00
EnergyTransfer:Zone:F6 NW APARTMENT 26.24 0.00 16-OCT-12:30 4371.45 07-MAR-14:00
Heating:EnergyTransfer:Zone:F6 NW APARTMENT 19.60 0.00 01-FEB-19:45 4371.45 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT 6.64 0.00 01-JAN-00:15 2942.15 01-JUL-18:30
EnergyTransfer:Zone:F6 SE APARTMENT 24.24 0.02 12-DEC-13:15 4062.71 07-MAR-14:00
Heating:EnergyTransfer:Zone:F6 SE APARTMENT 15.09 0.00 01-JAN-11:15 4062.71 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT 9.15 0.00 01-JAN-00:15 2933.49 29-JUL-15:30
EnergyTransfer:Zone:F6 NE APARTMENT 25.94 0.01 02-NOV-15:00 4339.54 07-MAR-14:00
Heating:EnergyTransfer:Zone:F6 NE APARTMENT 19.30 0.00 01-FEB-19:45 4339.54 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT 6.64 0.00 01-JAN-00:15 2234.71 29-JUL-15:30
EnergyTransfer:Zone:F6 N1 APARTMENT 15.07 0.04 16-MAY-16:00 2518.32 07-MAR-14:00
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT 9.12 0.00 14-JAN-22:45 2518.32 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT 5.95 0.00 01-JAN-00:15 1884.97 01-JUL-18:45
EnergyTransfer:Zone:F6 N2 APARTMENT 15.07 0.02 10-JUL-09:30 2515.06 07-MAR-14:00
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT 9.12 0.00 14-JAN-22:45 2515.06 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT 5.95 0.00 01-JAN-00:15 1861.19 01-JUL-18:45
EnergyTransfer:Zone:F6 S1 APARTMENT 15.12 0.04 12-JUN-19:45 2383.39 19-AUG-13:00
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT 5.94 0.00 01-JAN-10:00 2247.71 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT 9.18 0.00 01-JAN-00:15 2383.39 19-AUG-13:00
EnergyTransfer:Zone:F6 S2 APARTMENT 15.12 0.01 25-DEC-17:15 2392.05 19-AUG-13:00
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT 5.94 0.00 01-JAN-10:00 2244.81 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT 9.18 0.00 01-JAN-00:15 2392.05 19-AUG-13:00
EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F7 SW APARTMENT 25.09 0.04 11-SEP-09:45 4320.36 07-MAR-14:00
Heating:EnergyTransfer:Zone:F7 SW APARTMENT 16.33 0.00 01-JAN-11:30 4320.36 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT 8.76 0.00 01-JAN-00:15 3321.52 01-AUG-17:00
EnergyTransfer:Zone:F7 NW APARTMENT 27.16 0.01 17-MAY-10:45 4600.54 07-MAR-14:00
Heating:EnergyTransfer:Zone:F7 NW APARTMENT 20.80 0.00 01-FEB-19:45 4600.54 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT 6.36 0.00 01-JAN-00:15 2948.04 01-JUL-18:30
EnergyTransfer:Zone:F7 SE APARTMENT 24.90 0.02 04-OCT-08:00 4291.18 07-MAR-14:00
Heating:EnergyTransfer:Zone:F7 SE APARTMENT 16.18 0.00 01-JAN-11:30 4291.18 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT 8.72 0.00 01-JAN-00:15 2936.21 29-JUL-15:30
EnergyTransfer:Zone:F7 NE APARTMENT 26.84 0.08 14-OCT-02:30 4568.50 07-MAR-14:00
Heating:EnergyTransfer:Zone:F7 NE APARTMENT 20.49 0.00 01-FEB-19:45 4568.50 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT 6.35 0.00 01-JAN-00:15 2241.19 18-JUN-18:00
EnergyTransfer:Zone:F7 N1 APARTMENT 15.51 0.00 13-SEP-08:30 2661.59 07-MAR-14:00
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT 9.85 0.00 14-JAN-23:00 2661.59 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT 5.67 0.00 01-JAN-00:15 1891.19 01-JUL-18:45
EnergyTransfer:Zone:F7 N2 APARTMENT 15.51 0.01 18-SEP-12:45 2658.33 07-MAR-14:00
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT 9.85 0.00 14-JAN-23:00 2658.33 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT 5.66 0.00 01-JAN-00:15 1870.86 01-JUL-18:45
EnergyTransfer:Zone:F7 S1 APARTMENT 15.26 0.03 05-MAY-11:30 2390.06 07-MAR-14:00
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT 6.53 0.00 01-JAN-10:00 2390.06 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT 8.74 0.00 01-JAN-00:15 2383.59 19-AUG-13:00
EnergyTransfer:Zone:F7 S2 APARTMENT 15.26 0.02 29-APR-00:45 2392.26 19-AUG-13:00
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT 6.53 0.00 01-JAN-10:00 2387.13 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT 8.73 0.00 01-JAN-00:15 2392.26 19-AUG-13:00
EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F8 SW APARTMENT 25.85 0.00 10-JUN-00:15 4535.11 07-MAR-14:00
Heating:EnergyTransfer:Zone:F8 SW APARTMENT 17.41 0.00 01-JAN-11:30 4535.11 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT 8.44 0.00 01-JAN-00:15 3332.97 01-AUG-17:00
EnergyTransfer:Zone:F8 NW APARTMENT 28.12 0.02 02-OCT-09:15 4814.71 07-MAR-14:00
Heating:EnergyTransfer:Zone:F8 NW APARTMENT 21.95 0.00 01-FEB-19:45 4814.71 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT 6.17 0.00 01-JAN-00:15 2963.30 01-JUL-18:30
EnergyTransfer:Zone:F8 SE APARTMENT 25.64 0.01 10-SEP-19:00 4505.50 07-MAR-14:00
Heating:EnergyTransfer:Zone:F8 SE APARTMENT 17.24 0.00 01-JAN-11:30 4505.50 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT 8.40 0.00 01-JAN-00:15 2947.79 29-JUL-15:30
EnergyTransfer:Zone:F8 NE APARTMENT 27.78 0.13 01-OCT-05:45 4782.33 07-MAR-14:00
Heating:EnergyTransfer:Zone:F8 NE APARTMENT 21.63 0.00 01-FEB-19:45 4782.33 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT 6.15 0.00 01-JAN-00:15 2255.25 18-JUN-18:00
EnergyTransfer:Zone:F8 N1 APARTMENT 16.04 0.04 14-SEP-08:00 2798.55 07-MAR-14:00
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT 10.58 0.00 14-JAN-23:00 2798.55 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT 5.47 0.00 01-JAN-00:15 1906.17 01-JUL-18:45
EnergyTransfer:Zone:F8 N2 APARTMENT 16.04 0.02 24-JUN-20:15 2795.27 07-MAR-14:00
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT 10.58 0.00 14-JAN-23:00 2795.27 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT 5.46 0.00 01-JAN-00:15 1888.03 01-JUL-18:45
EnergyTransfer:Zone:F8 S1 APARTMENT 15.51 0.04 21-SEP-13:45 2527.31 07-MAR-14:00
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT 7.13 0.00 01-JAN-10:15 2527.31 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT 8.38 0.00 01-JAN-00:15 2387.25 19-AUG-13:00
EnergyTransfer:Zone:F8 S2 APARTMENT 15.51 0.06 02-AUG-05:45 2524.32 07-MAR-14:00
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT 7.13 0.00 01-JAN-10:15 2524.32 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT 8.37 0.00 01-JAN-00:15 2395.95 19-AUG-13:00
EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F9 SW APARTMENT 27.55 0.02 20-SEP-09:15 4811.97 07-MAR-14:00
Heating:EnergyTransfer:Zone:F9 SW APARTMENT 19.31 0.00 01-JAN-12:00 4811.97 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT 8.24 0.00 01-JAN-00:15 3472.94 01-AUG-16:45
EnergyTransfer:Zone:F9 NW APARTMENT 30.11 0.01 11-OCT-14:30 5096.19 07-MAR-14:00
Heating:EnergyTransfer:Zone:F9 NW APARTMENT 24.00 0.00 01-FEB-20:00 5096.19 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT 6.12 0.00 01-JAN-00:15 3052.31 01-JUL-18:30
EnergyTransfer:Zone:F9 SE APARTMENT 27.26 0.01 29-MAY-02:45 4778.37 07-MAR-14:00
Heating:EnergyTransfer:Zone:F9 SE APARTMENT 19.09 0.00 01-JAN-11:45 4778.37 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT 8.17 0.00 01-JAN-00:15 3011.11 29-JUL-15:45
EnergyTransfer:Zone:F9 NE APARTMENT 29.70 0.01 23-JUL-09:00 5060.00 07-MAR-14:00
Heating:EnergyTransfer:Zone:F9 NE APARTMENT 23.63 0.00 01-FEB-20:00 5060.00 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT 6.07 0.00 01-JAN-00:15 2368.25 18-JUN-17:45
EnergyTransfer:Zone:F9 N1 APARTMENT 17.46 0.03 08-JUL-15:15 3006.53 07-MAR-14:00
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT 12.12 0.00 15-JAN-23:00 3006.53 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT 5.34 0.00 01-JAN-00:15 1974.23 01-JUL-18:30
EnergyTransfer:Zone:F9 N2 APARTMENT 17.45 0.00 24-JUN-21:00 3002.89 07-MAR-14:00
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT 12.12 0.00 15-JAN-23:00 3002.89 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT 5.33 0.00 01-JAN-00:15 1957.02 01-JUL-18:30
EnergyTransfer:Zone:F9 S1 APARTMENT 16.43 0.00 20-JUN-18:45 2728.29 07-MAR-14:00
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT 8.39 0.00 01-JAN-10:45 2728.29 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT 8.03 0.00 01-JAN-00:15 2420.97 01-AUG-13:45
EnergyTransfer:Zone:F9 S2 APARTMENT 16.43 0.03 25-MAY-10:00 2724.86 07-MAR-14:00
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT 8.40 0.00 01-JAN-10:45 2724.86 07-MAR-14:00
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT 8.03 0.00 01-JAN-00:15 2429.40 01-AUG-13:45
EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:T SW APARTMENT 35.08 0.01 06-NOV-19:30 5492.75 07-FEB-02:00
Heating:EnergyTransfer:Zone:T SW APARTMENT 26.67 0.00 01-JAN-11:45 5492.75 07-FEB-02:00
Cooling:EnergyTransfer:Zone:T SW APARTMENT 8.41 0.00 01-JAN-00:15 4092.16 01-AUG-13:45
EnergyTransfer:Zone:T NW APARTMENT 37.07 0.02 29-MAY-17:45 5618.29 07-FEB-02:00
Heating:EnergyTransfer:Zone:T NW APARTMENT 30.73 0.00 18-FEB-14:15 5618.29 07-FEB-02:00
Cooling:EnergyTransfer:Zone:T NW APARTMENT 6.35 0.00 01-JAN-00:15 3448.46 20-JUL-15:30
EnergyTransfer:Zone:T SE APARTMENT 34.42 0.00 23-AUG-04:45 5463.15 07-FEB-02:00
Heating:EnergyTransfer:Zone:T SE APARTMENT 26.30 0.00 01-JAN-11:30 5463.15 07-FEB-02:00
Cooling:EnergyTransfer:Zone:T SE APARTMENT 8.12 0.00 01-JAN-00:15 3710.46 01-AUG-13:45
EnergyTransfer:Zone:T NE APARTMENT 36.32 0.03 18-MAY-02:00 5615.57 07-MAR-14:00
Heating:EnergyTransfer:Zone:T NE APARTMENT 30.19 0.00 18-FEB-15:00 5615.57 07-MAR-14:00
Cooling:EnergyTransfer:Zone:T NE APARTMENT 6.14 0.00 01-JAN-00:15 2810.14 29-JUL-15:45
EnergyTransfer:Zone:T N1 APARTMENT 23.32 0.01 26-OCT-19:45 3588.46 07-FEB-02:00
Heating:EnergyTransfer:Zone:T N1 APARTMENT 18.09 0.00 01-FEB-19:45 3588.46 07-FEB-02:00
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 5.22 0.00 01-JAN-00:15 2275.04 01-JUL-18:30
EnergyTransfer:Zone:T N2 APARTMENT 23.31 0.08 27-OCT-12:30 3587.19 07-FEB-02:00
Heating:EnergyTransfer:Zone:T N2 APARTMENT 18.10 0.00 01-FEB-19:45 3587.19 07-FEB-02:00
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 5.21 0.00 01-JAN-00:15 2240.43 01-JUL-18:30
EnergyTransfer:Zone:T S1 APARTMENT 22.00 0.01 10-MAY-08:00 3445.62 07-FEB-02:00
Heating:EnergyTransfer:Zone:T S1 APARTMENT 14.54 0.00 01-JAN-11:00 3445.62 07-FEB-02:00
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 7.46 0.00 01-JAN-00:15 3277.35 01-AUG-13:45
EnergyTransfer:Zone:T S2 APARTMENT 22.00 0.01 28-JUL-20:45 3443.97 07-FEB-02:00
Heating:EnergyTransfer:Zone:T S2 APARTMENT 14.54 0.00 01-JAN-11:00 3443.97 07-FEB-02:00
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 7.46 0.00 01-JAN-00:15 3284.66 01-AUG-13:45
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Plant 2135.16 503.62 11-AUG-01:15 287055.89 27-JAN-07:15
WaterSystems:EnergyTransfer 967.68 503.62 11-AUG-01:15 65716.65 19-FEB-07:30
sub cat:WaterSystems:EnergyTransfer 967.68 503.62 11-AUG-01:15 65716.65 19-FEB-07:30
EnergyTransfer:HVAC 2337.61 0.00 11-APR-18:30 323048.65 07-FEB-02:00
CoolingCoils:EnergyTransfer 761.83 0.00 01-JAN-00:15 305286.57 04-AUG-15:45
HeatingCoils:EnergyTransfer 1575.79 0.00 28-MAR-16:15 323048.65 07-FEB-02:00
PlantLoopHeatingDemand:HVAC 1210.38 0.00 28-MAR-16:15 223906.46 27-JAN-07:00
HeatingCoils:PlantLoopHeatingDemand 1210.38 0.00 28-MAR-16:15 223906.46 27-JAN-07:00
Boilers:EnergyTransfer 1167.47 0.00 17-MAR-11:45 221889.37 27-JAN-07:15



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 12.230 -5.801 0.000 0.000 3.886 1.087 12.213 16.834 0.000 0.167 0.000 0.000 -12.815 0.000 -11.638 -16.163
G NW APARTMENT 15.592 -4.106 0.000 0.000 3.909 1.087 12.213 8.687 0.000 0.154 0.000 0.000 -13.443 0.000 -11.179 -12.914
OFFICE 9.308 -14.077 0.000 0.000 0.533 29.882 9.495 16.561 0.000 0.080 0.000 0.000 -12.800 0.000 -8.358 -30.624
G NE APARTMENT 15.363 -4.007 0.000 0.000 3.917 1.087 12.213 8.511 0.000 0.154 0.000 0.000 -13.208 0.000 -11.193 -12.837
G N1 APARTMENT 9.130 -3.511 0.000 0.000 3.921 1.087 12.213 3.159 0.000 0.123 0.000 0.000 -8.455 0.000 -7.696 -9.969
G N2 APARTMENT 9.130 -3.503 0.000 0.000 3.921 1.087 12.213 3.157 0.000 0.123 0.000 0.000 -8.453 0.000 -7.698 -9.975
G S1 APARTMENT 5.918 -5.641 0.000 0.000 3.888 1.087 12.213 11.376 0.000 0.134 0.000 0.000 -7.805 0.000 -8.189 -12.979
G S2 APARTMENT 5.713 -5.824 0.000 0.000 3.883 1.087 12.213 11.357 0.000 0.134 0.000 0.000 -7.821 0.000 -8.247 -12.495
F2 SW APARTMENT 11.337 -9.589 0.000 0.000 3.830 1.087 12.213 16.181 0.000 0.222 0.000 0.000 -13.610 0.000 -16.215 -5.455
F2 NW APARTMENT 15.313 -6.673 0.000 0.000 3.870 1.087 12.213 8.253 0.000 0.202 0.000 0.000 -14.216 0.000 -15.516 -4.532
F2 SE APARTMENT 10.417 -10.593 0.000 0.000 3.819 1.087 12.213 15.950 0.000 0.222 0.001 0.000 -13.485 0.000 -16.404 -3.225
F2 NE APARTMENT 15.061 -6.716 0.000 0.000 3.881 1.087 12.213 8.092 0.000 0.198 0.000 0.000 -13.949 0.000 -15.493 -4.375
F2 N1 APARTMENT 7.216 -5.741 0.000 0.000 3.881 1.087 12.213 2.933 0.000 0.153 0.000 0.000 -8.989 0.000 -10.555 -2.198
F2 N2 APARTMENT 7.219 -5.741 0.000 0.000 3.882 1.087 12.213 2.932 0.000 0.153 0.000 0.000 -8.986 0.000 -10.554 -2.203
F2 S1 APARTMENT 4.328 -9.125 0.000 0.000 3.821 1.087 12.213 10.967 0.000 0.174 0.000 0.000 -8.294 0.000 -11.335 -3.836
F2 S2 APARTMENT 4.286 -9.223 0.000 0.000 3.819 1.087 12.213 10.960 0.000 0.175 0.000 0.000 -8.301 0.000 -11.358 -3.657
F3 SW APARTMENT 12.002 -10.041 0.000 0.000 3.823 1.087 12.213 15.933 0.000 0.293 0.001 0.000 -13.861 0.000 -18.761 -2.687
F3 NW APARTMENT 16.048 -7.097 0.000 0.000 3.865 1.087 12.213 8.101 0.000 0.261 0.000 0.000 -14.489 0.000 -17.965 -2.022
F3 SE APARTMENT 11.752 -10.172 0.000 0.000 3.824 1.087 12.213 15.765 0.000 0.291 0.001 0.000 -13.642 0.000 -18.836 -2.282
F3 NE APARTMENT 15.803 -7.124 0.000 0.000 3.875 1.087 12.213 7.947 0.000 0.254 0.000 0.000 -14.214 0.000 -17.937 -1.903
F3 N1 APARTMENT 7.258 -6.277 0.000 0.000 3.871 1.087 12.213 2.862 0.000 0.200 0.117 0.000 -9.176 0.000 -12.155 -0.000
F3 N2 APARTMENT 7.261 -6.276 0.000 0.000 3.872 1.087 12.213 2.862 0.000 0.200 0.109 0.000 -9.173 0.000 -12.153 -0.000
F3 S1 APARTMENT 4.411 -9.860 0.000 0.000 3.807 1.087 12.213 10.802 0.000 0.234 0.000 0.000 -8.466 0.000 -13.038 -1.189
F3 S2 APARTMENT 4.403 -9.888 0.000 0.000 3.807 1.087 12.213 10.798 0.000 0.235 0.000 0.000 -8.467 0.000 -13.049 -1.139
F4 SW APARTMENT 13.030 -9.933 0.000 0.000 3.823 1.087 12.213 15.785 0.000 0.319 0.000 0.000 -13.990 0.000 -20.418 -1.915
F4 NW APARTMENT 17.185 -7.082 0.000 0.000 3.864 1.087 12.213 8.014 0.000 0.283 0.000 0.000 -14.643 0.000 -19.588 -1.332
F4 SE APARTMENT 12.889 -9.942 0.000 0.000 3.827 1.087 12.213 15.634 0.000 0.316 0.000 0.000 -13.750 0.000 -20.462 -1.812
F4 NE APARTMENT 16.932 -7.117 0.000 0.000 3.874 1.087 12.213 7.866 0.000 0.274 0.000 0.000 -14.363 0.000 -19.553 -1.212
F4 N1 APARTMENT 7.777 -6.347 0.000 0.000 3.868 1.087 12.213 2.825 0.000 0.215 0.777 0.000 -9.282 0.000 -13.133 -0.000
F4 N2 APARTMENT 7.777 -6.341 0.000 0.000 3.869 1.087 12.213 2.824 0.000 0.215 0.768 0.000 -9.279 0.000 -13.132 -0.000
F4 S1 APARTMENT 4.849 -9.894 0.000 0.000 3.805 1.087 12.213 10.704 0.000 0.253 0.000 0.000 -8.551 0.000 -14.047 -0.418
F4 S2 APARTMENT 4.848 -9.898 0.000 0.000 3.805 1.087 12.213 10.702 0.000 0.254 0.000 0.000 -8.551 0.000 -14.054 -0.406
M SW APARTMENT 13.878 -9.836 0.000 0.000 3.826 1.087 12.213 15.673 0.000 0.339 0.001 0.000 -14.091 0.000 -21.971 -1.117
M NW APARTMENT 18.073 -7.105 0.000 0.000 3.865 1.087 12.213 7.949 0.000 0.300 0.000 0.000 -14.766 0.000 -21.092 -0.524
M SE APARTMENT 13.749 -9.820 0.000 0.000 3.830 1.087 12.213 15.529 0.000 0.336 0.001 0.000 -13.844 0.000 -22.011 -1.069
M NE APARTMENT 17.799 -7.130 0.000 0.000 3.875 1.087 12.213 7.805 0.000 0.290 0.000 0.000 -14.484 0.000 -21.053 -0.402
M N1 APARTMENT 8.170 -6.420 0.000 0.000 3.868 1.087 12.213 2.798 0.000 0.227 1.523 0.000 -9.365 0.000 -14.100 -0.000
M N2 APARTMENT 8.172 -6.418 0.000 0.000 3.869 1.087 12.213 2.797 0.000 0.227 1.515 0.000 -9.362 0.000 -14.099 -0.000
M S1 APARTMENT 5.217 -9.880 0.000 0.000 3.806 1.087 12.213 10.632 0.000 0.268 0.336 0.000 -8.615 0.000 -15.063 -0.000
M S2 APARTMENT 5.218 -9.877 0.000 0.000 3.807 1.087 12.213 10.630 0.000 0.269 0.338 0.000 -8.614 0.000 -15.068 -0.000
F6 SW APARTMENT 15.228 -9.172 0.000 0.000 3.834 1.087 12.213 15.617 0.000 0.356 0.000 0.000 -14.113 0.000 -23.233 -1.818
F6 NW APARTMENT 19.600 -6.638 0.000 0.000 3.872 1.087 12.213 7.927 0.000 0.315 0.000 0.000 -14.807 0.000 -22.309 -1.260
F6 SE APARTMENT 15.087 -9.149 0.000 0.000 3.840 1.087 12.213 15.478 0.000 0.352 0.000 0.000 -13.863 0.000 -23.272 -1.772
F6 NE APARTMENT 19.304 -6.639 0.000 0.000 3.883 1.087 12.213 7.787 0.000 0.304 0.000 0.000 -14.524 0.000 -22.269 -1.144
F6 N1 APARTMENT 9.119 -5.951 0.000 0.000 3.876 1.087 12.213 2.796 0.000 0.237 0.864 0.000 -9.390 0.000 -14.850 -0.000
F6 N2 APARTMENT 9.119 -5.946 0.000 0.000 3.877 1.087 12.213 2.795 0.000 0.236 0.855 0.000 -9.387 0.000 -14.848 -0.000
F6 S1 APARTMENT 5.937 -9.183 0.000 0.000 3.816 1.087 12.213 10.596 0.000 0.280 0.000 0.000 -8.625 0.000 -15.854 -0.267
F6 S2 APARTMENT 5.939 -9.179 0.000 0.000 3.816 1.087 12.213 10.594 0.000 0.281 0.001 0.000 -8.623 0.000 -15.859 -0.268
F7 SW APARTMENT 16.334 -8.756 0.000 0.000 3.841 1.087 12.213 15.564 0.000 0.370 0.001 0.000 -14.142 0.000 -24.348 -2.162
F7 NW APARTMENT 20.796 -6.362 0.000 0.000 3.878 1.087 12.213 7.903 0.000 0.326 0.000 0.000 -14.854 0.000 -23.390 -1.597
F7 SE APARTMENT 16.177 -8.723 0.000 0.000 3.847 1.087 12.213 15.428 0.000 0.366 0.001 0.000 -13.891 0.000 -24.387 -2.116
F7 NE APARTMENT 20.488 -6.351 0.000 0.000 3.888 1.087 12.213 7.765 0.000 0.315 0.000 0.000 -14.570 0.000 -23.350 -1.484
F7 N1 APARTMENT 9.845 -5.667 0.000 0.000 3.881 1.087 12.213 2.790 0.000 0.245 0.543 0.000 -9.420 0.000 -15.517 -0.000
F7 N2 APARTMENT 9.846 -5.663 0.000 0.000 3.882 1.087 12.213 2.790 0.000 0.245 0.534 0.000 -9.417 0.000 -15.515 -0.001
F7 S1 APARTMENT 6.527 -8.735 0.000 0.000 3.824 1.087 12.213 10.563 0.000 0.291 0.001 0.000 -8.639 0.000 -16.550 -0.580
F7 S2 APARTMENT 6.529 -8.732 0.000 0.000 3.824 1.087 12.213 10.561 0.000 0.291 0.001 0.000 -8.637 0.000 -16.555 -0.581
F8 SW APARTMENT 17.411 -8.439 0.000 0.000 3.847 1.087 12.213 15.517 0.000 0.382 0.000 0.000 -14.169 0.000 -25.376 -2.473
F8 NW APARTMENT 21.947 -6.172 0.000 0.000 3.882 1.087 12.213 7.881 0.000 0.337 0.000 0.000 -14.898 0.000 -24.390 -1.886
F8 SE APARTMENT 17.237 -8.399 0.000 0.000 3.853 1.087 12.213 15.384 0.000 0.378 0.000 0.000 -13.916 0.000 -25.415 -2.422
F8 NE APARTMENT 21.628 -6.149 0.000 0.000 3.892 1.087 12.213 7.745 0.000 0.325 0.000 0.000 -14.613 0.000 -24.350 -1.778
F8 N1 APARTMENT 10.578 -5.467 0.000 0.000 3.886 1.087 12.213 2.784 0.000 0.253 0.256 0.000 -9.446 0.000 -16.143 -0.000
F8 N2 APARTMENT 10.575 -5.460 0.000 0.000 3.887 1.087 12.213 2.784 0.000 0.252 0.248 0.000 -9.443 0.000 -16.141 -0.000
F8 S1 APARTMENT 7.130 -8.376 0.000 0.000 3.831 1.087 12.213 10.533 0.000 0.299 0.000 0.000 -8.650 0.000 -17.199 -0.869
F8 S2 APARTMENT 7.135 -8.373 0.000 0.000 3.832 1.087 12.213 10.532 0.000 0.300 0.000 0.000 -8.649 0.000 -17.205 -0.870
F9 SW APARTMENT 19.310 -8.238 0.000 0.000 3.853 1.087 12.213 15.491 0.000 0.402 0.000 0.000 -14.161 0.000 -26.302 -3.654
F9 NW APARTMENT 23.995 -6.116 0.000 0.000 3.885 1.087 12.213 7.867 0.000 0.354 0.000 0.000 -14.909 0.000 -25.305 -3.071
F9 SE APARTMENT 19.094 -8.170 0.000 0.000 3.859 1.087 12.213 15.361 0.000 0.399 0.000 0.000 -13.909 0.000 -26.345 -3.588
F9 NE APARTMENT 23.633 -6.068 0.000 0.000 3.896 1.087 12.213 7.734 0.000 0.340 0.000 0.000 -14.623 0.000 -25.262 -2.950
F9 N1 APARTMENT 12.121 -5.336 0.000 0.000 3.889 1.087 12.213 2.782 0.000 0.268 0.000 0.000 -9.449 0.000 -16.720 -0.855
F9 N2 APARTMENT 12.119 -5.332 0.000 0.000 3.890 1.087 12.213 2.782 0.000 0.267 0.000 0.000 -9.446 0.000 -16.718 -0.862
F9 S1 APARTMENT 8.395 -8.034 0.000 0.000 3.839 1.087 12.213 10.519 0.000 0.317 0.000 0.000 -8.639 0.000 -17.782 -1.914
F9 S2 APARTMENT 8.398 -8.031 0.000 0.000 3.840 1.087 12.213 10.517 0.000 0.317 0.000 0.000 -8.637 0.000 -17.788 -1.915
T SW APARTMENT 26.669 -8.411 0.000 0.000 3.879 1.087 12.213 15.295 0.000 0.415 0.000 0.000 -13.673 0.000 -27.124 -10.349
T NW APARTMENT 30.728 -6.345 0.000 0.000 3.902 1.087 12.213 7.720 0.000 0.363 0.000 0.000 -14.474 0.000 -26.161 -9.031
T SE APARTMENT 26.299 -8.122 0.000 0.000 3.886 1.087 12.213 15.189 0.000 0.411 0.000 0.000 -13.446 0.000 -27.173 -10.344
T NE APARTMENT 30.185 -6.138 0.000 0.000 3.915 1.087 12.213 7.614 0.000 0.354 0.000 0.000 -14.212 0.000 -26.106 -8.912
T N1 APARTMENT 18.094 -5.220 0.000 0.000 3.907 1.087 12.213 2.738 0.000 0.277 0.000 0.000 -9.159 0.000 -17.252 -6.684
T N2 APARTMENT 18.096 -5.211 0.000 0.000 3.907 1.087 12.213 2.735 0.000 0.277 0.000 0.000 -9.155 0.000 -17.255 -6.695
T S1 APARTMENT 14.535 -7.464 0.000 0.000 3.866 1.087 12.213 10.416 0.000 0.332 0.000 0.000 -8.372 0.000 -18.329 -8.284
T S2 APARTMENT 14.540 -7.464 0.000 0.000 3.867 1.087 12.213 10.412 0.000 0.332 0.000 0.000 -8.369 0.000 -18.337 -8.281
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 3.789 0.000 0.475 55.346 0.000 -2.780 0.000 -73.270 -0.002
F2 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.670 0.000 0.007 0.000 0.000 -1.731 0.000 -2.107 -14.280
F3 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.627 0.000 0.008 0.000 0.000 -1.807 0.000 -2.560 -13.709
F4 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.604 0.000 0.008 0.000 0.000 -1.839 0.000 -2.883 -13.330
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 32.880 0.000 1.579 0.000 0.007 0.000 0.000 -1.883 0.000 -3.238 -29.345
F6 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.587 0.000 0.010 0.000 0.000 -1.857 0.000 -3.337 -12.843
F7 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.587 0.000 0.011 0.000 0.000 -1.851 0.000 -3.498 -12.689
F8 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.584 0.000 0.011 0.000 0.000 -1.850 0.000 -3.653 -12.531
F9 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.582 0.000 0.011 0.000 0.000 -1.845 0.000 -3.783 -12.405
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 8.151 1.542 0.000 0.005 0.000 0.000 -1.795 0.000 -3.981 -20.363
Total Facility 1037.789 -597.030 0.000 0.000 305.562 296.560 982.450 762.587 0.000 22.234 64.143 0.000 -936.226 0.000 -1514.958 -423.100


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 13-SEP-15:15 0.00 -2540.40 0.00 0.00 48.90 45.40 470.89 3596.36 0.00 288.89 0.00 0.00 0.00 0.00 0.00 -1910.05
G NW APARTMENT 05-JUL-17:30 0.00 -2162.10 0.00 0.00 141.82 87.56 588.62 2620.89 0.00 259.02 0.00 0.00 0.00 0.00 0.00 -1535.81
OFFICE 20-JUL-13:00 0.00 -3517.48 0.00 0.00 65.04 2345.88 588.62 2463.94 0.00 178.92 0.00 0.00 0.00 0.00 0.00 -2124.92
G NE APARTMENT 15-JUL-09:15 0.00 -1632.16 0.00 0.00 40.75 12.97 406.15 2466.44 0.00 280.72 0.00 0.00 0.00 0.00 0.00 -1574.87
G N1 APARTMENT 01-JUL-18:30 0.00 -1284.24 0.00 0.00 141.82 103.77 547.42 636.42 0.00 303.15 0.00 0.00 0.00 0.00 0.00 -448.34
G N2 APARTMENT 01-JUL-18:30 0.00 -1261.11 0.00 0.00 141.82 103.77 547.42 637.05 0.00 303.14 0.00 0.00 0.00 0.00 0.00 -472.09
G S1 APARTMENT 01-AUG-13:45 0.00 -1673.24 0.00 0.00 40.75 12.97 382.60 2084.46 0.00 328.56 0.00 0.00 0.00 0.00 0.00 -1176.10
G S2 APARTMENT 01-AUG-13:45 0.00 -1742.29 0.00 0.00 40.75 12.97 382.60 2083.43 0.00 330.97 0.00 0.00 0.00 0.00 0.00 -1108.43
F2 SW APARTMENT 13-SEP-15:15 0.00 -3195.87 0.00 0.00 48.90 45.40 470.89 3539.13 0.00 359.97 0.00 0.00 0.00 0.00 0.00 -1268.42
F2 NW APARTMENT 01-JUL-18:30 0.00 -2791.11 0.00 0.00 141.82 103.77 547.42 1782.52 0.00 405.86 0.00 0.00 0.00 0.00 0.00 -190.27
F2 SE APARTMENT 02-SEP-12:45 0.00 -2930.72 0.00 0.00 40.24 12.97 388.49 3014.77 0.00 438.01 0.00 0.00 0.00 0.00 0.00 -963.77
F2 NE APARTMENT 29-JUL-16:15 0.00 -2112.94 0.00 0.00 84.76 64.86 588.62 696.94 0.00 729.95 0.00 0.00 0.00 0.00 0.00 -52.19
F2 N1 APARTMENT 01-JUL-18:30 0.00 -1730.49 0.00 0.00 141.82 103.77 547.42 620.00 0.00 375.50 0.00 0.00 0.00 0.00 0.00 -58.01
F2 N2 APARTMENT 01-JUL-18:30 0.00 -1713.41 0.00 0.00 141.82 103.77 547.42 620.46 0.00 376.12 0.00 0.00 0.00 0.00 0.00 -76.18
F2 S1 APARTMENT 01-AUG-13:45 0.00 -2238.52 0.00 0.00 40.75 12.97 382.60 2042.96 0.00 422.69 0.00 0.00 0.00 0.00 0.00 -663.46
F2 S2 APARTMENT 01-AUG-13:45 0.00 -2262.79 0.00 0.00 40.75 12.97 382.60 2042.77 0.00 424.43 0.00 0.00 0.00 0.00 0.00 -640.73
F3 SW APARTMENT 13-SEP-15:15 0.00 -3254.12 0.00 0.00 48.90 45.40 470.89 3508.97 0.00 404.05 0.00 0.00 0.00 0.00 0.00 -1224.11
F3 NW APARTMENT 01-JUL-18:30 0.00 -2862.17 0.00 0.00 141.82 103.77 547.42 1769.49 0.00 457.65 0.00 0.00 0.00 0.00 0.00 -157.97
F3 SE APARTMENT 29-JUL-15:45 0.00 -2882.19 0.00 0.00 48.91 45.40 470.89 886.58 0.00 1439.71 0.00 0.00 0.00 0.00 0.00 -9.30
F3 NE APARTMENT 29-JUL-15:45 0.00 -2189.97 0.00 0.00 48.91 45.40 470.89 851.92 0.00 931.93 0.00 0.00 0.00 0.00 0.00 -159.08
F3 N1 APARTMENT 01-JUL-18:30 0.00 -1800.77 0.00 0.00 141.82 103.77 547.42 615.70 0.00 419.18 0.00 0.00 0.00 0.00 0.00 -27.11
F3 N2 APARTMENT 01-JUL-18:30 0.00 -1783.81 0.00 0.00 141.82 103.77 547.42 616.15 0.00 419.79 0.00 0.00 0.00 0.00 0.00 -45.12
F3 S1 APARTMENT 01-AUG-13:45 0.00 -2303.80 0.00 0.00 40.75 12.97 382.60 2022.12 0.00 474.99 0.00 0.00 0.00 0.00 0.00 -629.63
F3 S2 APARTMENT 01-AUG-13:45 0.00 -2314.52 0.00 0.00 40.75 12.97 382.60 2022.06 0.00 476.21 0.00 0.00 0.00 0.00 0.00 -620.08
F4 SW APARTMENT 01-AUG-17:00 0.00 -3281.46 0.00 0.00 84.77 64.86 588.62 2308.56 0.00 535.72 0.00 0.00 0.00 0.00 0.00 -301.06
F4 NW APARTMENT 01-JUL-18:30 0.00 -2902.77 0.00 0.00 141.82 103.77 547.42 1760.57 0.00 496.24 0.00 0.00 0.00 0.00 0.00 -147.05
F4 SE APARTMENT 29-JUL-15:30 0.00 -2910.52 0.00 0.00 48.90 45.40 470.89 984.36 0.00 1335.33 25.63 0.00 0.00 0.00 0.00 0.00
F4 NE APARTMENT 29-JUL-15:30 0.00 -2224.00 0.00 0.00 48.90 45.40 470.89 925.81 0.00 860.23 0.00 0.00 0.00 0.00 0.00 -127.24
F4 N1 APARTMENT 01-JUL-18:45 0.00 -1837.38 0.00 0.00 141.40 103.77 547.42 562.52 0.00 366.29 115.98 0.00 0.00 0.00 0.00 0.00
F4 N2 APARTMENT 01-JUL-18:30 0.00 -1817.00 0.00 0.00 141.82 103.77 547.42 613.46 0.00 452.36 0.00 0.00 0.00 0.00 0.00 -41.82
F4 S1 APARTMENT 19-AUG-13:00 0.00 -2349.30 0.00 0.00 40.75 12.97 388.49 2228.79 0.00 486.05 0.00 0.00 0.00 0.00 0.00 -807.76
F4 S2 APARTMENT 19-AUG-13:00 0.00 -2358.18 0.00 0.00 40.75 12.97 388.49 2228.62 0.00 486.05 0.00 0.00 0.00 0.00 0.00 -798.71
M SW APARTMENT 01-AUG-17:00 0.00 -3331.31 0.00 0.00 84.77 64.86 588.62 2298.87 0.00 569.84 0.00 0.00 0.00 0.00 0.00 -275.64
M NW APARTMENT 01-JUL-18:30 0.00 -2954.36 0.00 0.00 141.82 103.77 547.42 1753.03 0.00 527.11 0.00 0.00 0.00 0.00 0.00 -118.79
M SE APARTMENT 29-JUL-15:30 0.00 -2954.03 0.00 0.00 48.91 45.40 470.89 979.94 0.00 1415.22 0.00 0.00 0.00 0.00 0.00 -6.33
M NE APARTMENT 29-JUL-15:30 0.00 -2262.28 0.00 0.00 48.90 45.40 470.89 922.12 0.00 912.46 0.00 0.00 0.00 0.00 0.00 -137.50
M N1 APARTMENT 01-JUL-18:45 0.00 -1890.03 0.00 0.00 141.36 103.77 547.42 560.27 0.00 387.76 149.45 0.00 0.00 0.00 0.00 0.00
M N2 APARTMENT 01-JUL-18:45 0.00 -1866.05 0.00 0.00 141.39 103.77 547.42 560.74 0.00 387.88 124.87 0.00 0.00 0.00 0.00 0.00
M S1 APARTMENT 19-AUG-13:00 0.00 -2400.18 0.00 0.00 40.75 12.97 388.49 2217.23 0.00 516.00 0.00 0.00 0.00 0.00 0.00 -775.26
M S2 APARTMENT 19-AUG-13:00 0.00 -2408.83 0.00 0.00 40.75 12.97 388.49 2217.06 0.00 516.00 0.00 0.00 0.00 0.00 0.00 -766.44
F6 SW APARTMENT 01-AUG-17:00 0.00 -3316.10 0.00 0.00 84.77 64.86 588.62 2292.46 0.00 598.20 0.00 0.00 0.00 0.00 0.00 -312.80
F6 NW APARTMENT 01-JUL-18:30 0.00 -2941.15 0.00 0.00 141.82 103.77 547.42 1748.33 0.00 552.76 0.00 0.00 0.00 0.00 0.00 -152.94
F6 SE APARTMENT 29-JUL-15:30 0.00 -2934.94 0.00 0.00 48.91 45.40 470.89 978.36 0.00 1479.62 0.00 0.00 0.00 0.00 0.00 -88.24
F6 NE APARTMENT 29-JUL-15:30 0.00 -2235.63 0.00 0.00 48.91 45.40 470.89 921.14 0.00 954.90 0.00 0.00 0.00 0.00 0.00 -205.61
F6 N1 APARTMENT 01-JUL-18:45 0.00 -1883.84 0.00 0.00 141.28 103.77 547.42 559.41 0.00 405.35 126.61 0.00 0.00 0.00 0.00 0.00
F6 N2 APARTMENT 01-JUL-18:45 0.00 -1860.06 0.00 0.00 141.31 103.77 547.42 559.88 0.00 405.46 102.23 0.00 0.00 0.00 0.00 0.00
F6 S1 APARTMENT 19-AUG-13:00 0.00 -2383.05 0.00 0.00 40.75 12.97 388.49 2208.81 0.00 540.92 0.00 0.00 0.00 0.00 0.00 -808.89
F6 S2 APARTMENT 19-AUG-13:00 0.00 -2391.72 0.00 0.00 40.75 12.97 388.49 2208.64 0.00 540.92 0.00 0.00 0.00 0.00 0.00 -800.06
F7 SW APARTMENT 01-AUG-17:00 0.00 -3320.95 0.00 0.00 84.77 64.86 588.62 2286.33 0.00 622.35 0.00 0.00 0.00 0.00 0.00 -325.98
F7 NW APARTMENT 01-JUL-18:30 0.00 -2947.02 0.00 0.00 141.82 103.77 547.42 1743.77 0.00 574.57 0.00 0.00 0.00 0.00 0.00 -164.31
F7 SE APARTMENT 29-JUL-15:30 0.00 -2937.66 0.00 0.00 48.91 45.40 470.89 976.44 0.00 1534.90 0.00 0.00 0.00 0.00 0.00 -138.87
F7 NE APARTMENT 18-JUN-18:00 0.00 -2240.58 0.00 0.00 141.82 87.56 588.62 707.07 0.00 545.70 169.81 0.00 0.00 0.00 0.00 0.00
F7 N1 APARTMENT 01-JUL-18:45 0.00 -1890.03 0.00 0.00 141.23 103.77 547.42 558.29 0.00 419.73 119.59 0.00 0.00 0.00 0.00 0.00
F7 N2 APARTMENT 01-JUL-18:45 0.00 -1869.71 0.00 0.00 141.26 103.77 547.42 558.75 0.00 420.33 98.18 0.00 0.00 0.00 0.00 0.00
F7 S1 APARTMENT 19-AUG-13:00 0.00 -2383.25 0.00 0.00 40.75 12.97 388.49 2201.31 0.00 562.15 0.00 0.00 0.00 0.00 0.00 -822.41
F7 S2 APARTMENT 19-AUG-13:00 0.00 -2391.92 0.00 0.00 40.75 12.97 388.49 2201.14 0.00 562.15 0.00 0.00 0.00 0.00 0.00 -813.57
F8 SW APARTMENT 01-AUG-17:00 0.00 -3332.38 0.00 0.00 84.77 64.86 588.62 2280.69 0.00 643.22 0.00 0.00 0.00 0.00 0.00 -329.77
F8 NW APARTMENT 01-JUL-18:30 0.00 -2962.27 0.00 0.00 141.82 103.77 547.42 1739.39 0.00 593.39 0.00 0.00 0.00 0.00 0.00 -163.51
F8 SE APARTMENT 29-JUL-15:30 0.00 -2949.24 0.00 0.00 48.91 45.40 470.89 974.51 0.00 1583.38 0.00 0.00 0.00 0.00 0.00 -173.86
F8 NE APARTMENT 18-JUN-18:00 0.00 -2254.62 0.00 0.00 141.82 87.56 588.62 705.55 0.00 562.75 168.32 0.00 0.00 0.00 0.00 0.00
F8 N1 APARTMENT 01-JUL-18:45 0.00 -1905.00 0.00 0.00 141.21 103.77 547.42 557.02 0.00 432.17 123.41 0.00 0.00 0.00 0.00 0.00
F8 N2 APARTMENT 01-JUL-18:45 0.00 -1886.86 0.00 0.00 141.24 103.77 547.42 557.49 0.00 433.11 103.85 0.00 0.00 0.00 0.00 0.00
F8 S1 APARTMENT 19-AUG-13:00 0.00 -2386.92 0.00 0.00 40.75 12.97 388.49 2194.67 0.00 580.50 0.00 0.00 0.00 0.00 0.00 -830.47
F8 S2 APARTMENT 19-AUG-13:00 0.00 -2395.61 0.00 0.00 40.75 12.97 388.49 2194.50 0.00 580.50 0.00 0.00 0.00 0.00 0.00 -821.60
F9 SW APARTMENT 01-AUG-16:45 0.00 -3472.37 0.00 0.00 84.77 64.86 588.62 2451.55 0.00 665.02 0.00 0.00 0.00 0.00 0.00 -382.44
F9 NW APARTMENT 01-JUL-18:30 0.00 -3051.25 0.00 0.00 141.81 103.77 547.42 1732.76 0.00 609.80 0.00 0.00 0.00 0.00 0.00 -84.31
F9 SE APARTMENT 29-JUL-15:45 0.00 -3012.23 0.00 0.00 48.52 45.40 470.89 870.04 0.00 1818.46 0.00 0.00 0.00 0.00 0.00 -241.09
F9 NE APARTMENT 18-JUN-17:45 0.00 -2367.82 0.00 0.00 141.82 87.56 588.62 726.89 0.00 625.04 197.90 0.00 0.00 0.00 0.00 0.00
F9 N1 APARTMENT 01-JUL-18:30 0.00 -1973.18 0.00 0.00 141.82 103.77 547.42 604.02 0.00 551.08 25.08 0.00 0.00 0.00 0.00 0.00
F9 N2 APARTMENT 01-JUL-18:30 0.00 -1955.97 0.00 0.00 141.82 103.77 547.42 604.48 0.00 551.86 6.63 0.00 0.00 0.00 0.00 0.00
F9 S1 APARTMENT 01-AUG-13:45 0.00 -2421.94 0.00 0.00 40.75 12.97 382.60 1967.47 0.00 631.46 0.00 0.00 0.00 0.00 0.00 -613.32
F9 S2 APARTMENT 01-AUG-13:45 0.00 -2430.37 0.00 0.00 40.75 12.97 382.60 1967.41 0.00 632.76 0.00 0.00 0.00 0.00 0.00 -606.13
T SW APARTMENT 01-AUG-13:45 0.00 -4093.93 0.00 0.00 40.75 12.97 382.60 3245.01 0.00 714.87 0.00 0.00 0.00 0.00 0.00 -302.28
T NW APARTMENT 20-JUL-15:30 0.00 -3449.07 0.00 0.00 46.24 45.40 470.89 2782.97 0.00 656.49 0.00 0.00 0.00 0.00 0.00 -552.93
T SE APARTMENT 01-AUG-13:45 0.00 -3712.33 0.00 0.00 40.75 12.97 382.60 2259.89 0.00 714.82 301.30 0.00 0.00 0.00 0.00 0.00
T NE APARTMENT 29-JUL-15:45 0.00 -2811.15 0.00 0.00 48.91 45.40 470.89 814.46 0.00 1335.50 95.99 0.00 0.00 0.00 0.00 0.00
T N1 APARTMENT 01-JUL-18:30 0.00 -2273.93 0.00 0.00 141.82 103.77 547.42 595.02 0.00 578.06 307.85 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 01-JUL-18:30 0.00 -2239.33 0.00 0.00 141.82 103.77 547.42 595.89 0.00 578.05 272.39 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 01-AUG-13:45 0.00 -3278.91 0.00 0.00 40.75 12.97 382.60 1934.26 0.00 659.39 248.93 0.00 0.00 0.00 0.00 0.00
T S2 APARTMENT 01-AUG-13:45 0.00 -3286.22 0.00 0.00 40.75 12.97 382.60 1934.25 0.00 661.19 254.46 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 29-JUL-16:15 0.00 -179922.27 0.00 0.00 6545.00 11327.17 47212.47 57933.58 0.00 79430.75 0.00 0.00 0.00 0.00 -139.08 -22387.62


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 17-DEC-08:30 2639.17 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -1143.92 0.00 -1391.04 -586.13
G NW APARTMENT 27-JAN-08:15 3010.74 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -1554.73 0.00 -762.53 -1175.39
OFFICE 17-DEC-08:25 2656.55 0.00 0.00 0.00 0.00 469.18 194.24 0.00 0.00 0.00 0.00 0.00 -1109.74 0.00 -1391.04 -819.20
G NE APARTMENT 07-FEB-18:00 2769.64 0.00 0.00 0.00 98.63 64.86 588.62 0.00 0.00 0.00 0.00 0.00 -1292.94 0.00 -1557.89 -670.93
G N1 APARTMENT 27-JAN-08:15 2034.36 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -943.79 0.00 -459.94 -1112.54
G N2 APARTMENT 27-JAN-08:15 2030.71 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -943.84 0.00 -459.94 -1108.85
G S1 APARTMENT 17-DEC-08:30 1610.64 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -678.07 0.00 -839.04 -575.45
G S2 APARTMENT 17-DEC-08:30 1602.96 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -678.25 0.00 -839.04 -567.59
F2 SW APARTMENT 07-FEB-02:00 2966.47 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 49.71 0.00 -1577.63 0.00 -1876.04 0.00
F2 NW APARTMENT 07-FEB-02:00 3257.44 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -1565.46 0.00 -1876.04 -253.44
F2 SE APARTMENT 07-FEB-02:00 2842.99 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 166.72 0.00 -1571.16 0.00 -1876.04 0.00
F2 NE APARTMENT 07-FEB-02:00 3215.15 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -1555.81 0.00 -1876.05 -220.78
F2 N1 APARTMENT 07-FEB-02:00 1877.25 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -955.65 0.00 -1131.58 -227.51
F2 N2 APARTMENT 07-FEB-02:00 1874.83 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -955.70 0.00 -1131.58 -225.04
F2 S1 APARTMENT 25-JAN-05:00 1613.52 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 0.00 0.00 -922.37 0.00 -916.85 -207.11
F2 S2 APARTMENT 25-JAN-05:00 1608.49 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 0.00 0.00 -922.48 0.00 -916.85 -201.96
F3 SW APARTMENT 07-MAR-14:00 3233.72 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -163.78 0.00 -2773.24 -745.58
F3 NW APARTMENT 07-MAR-14:00 3510.00 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -584.81 0.00 -2773.24 -600.82
F3 SE APARTMENT 07-MAR-14:00 3199.38 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -347.18 0.00 -2773.24 -527.83
F3 NE APARTMENT 07-MAR-14:00 3478.84 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -767.91 0.00 -2773.26 -386.54
F3 N1 APARTMENT 07-MAR-14:00 2006.85 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -471.71 0.00 -1672.76 -311.25
F3 N2 APARTMENT 07-MAR-14:00 2003.57 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -471.81 0.00 -1672.76 -307.88
F3 S1 APARTMENT 07-MAR-14:00 1739.68 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -44.90 0.00 -1672.75 -470.91
F3 S2 APARTMENT 07-MAR-14:00 1736.18 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -45.03 0.00 -1672.75 -467.28
F4 SW APARTMENT 07-MAR-14:00 3558.38 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -182.99 0.00 -3101.02 -723.24
F4 NW APARTMENT 07-MAR-14:00 3836.43 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -604.64 0.00 -3101.02 -579.65
F4 SE APARTMENT 07-MAR-14:00 3529.45 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -364.69 0.00 -3101.02 -512.61
F4 NE APARTMENT 07-MAR-14:00 3804.98 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -786.32 0.00 -3101.04 -366.50
F4 N1 APARTMENT 07-MAR-14:00 2194.42 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -483.12 0.00 -1870.47 -289.71
F4 N2 APARTMENT 07-MAR-14:00 2191.16 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -483.22 0.00 -1870.47 -286.35
F4 S1 APARTMENT 07-MAR-14:00 1926.00 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -55.64 0.00 -1870.45 -448.78
F4 S2 APARTMENT 07-MAR-14:00 1923.06 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -55.75 0.00 -1870.45 -445.73
M SW APARTMENT 07-MAR-14:00 3820.58 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -197.76 0.00 -3371.46 -700.24
M NW APARTMENT 07-MAR-14:00 4097.19 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -619.71 0.00 -3371.46 -554.89
M SE APARTMENT 07-MAR-14:00 3792.02 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -378.40 0.00 -3371.46 -491.04
M NE APARTMENT 07-MAR-14:00 4065.55 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -800.35 0.00 -3371.48 -342.59
M N1 APARTMENT 07-MAR-14:00 2342.83 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -491.81 0.00 -2033.59 -266.31
M N2 APARTMENT 07-MAR-14:00 2339.60 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -491.91 0.00 -2033.59 -262.97
M S1 APARTMENT 07-MAR-14:00 2077.80 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -63.95 0.00 -2033.57 -429.15
M S2 APARTMENT 07-MAR-14:00 2075.01 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -64.07 0.00 -2033.57 -426.24
F6 SW APARTMENT 07-MAR-14:00 4091.21 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -207.48 0.00 -3604.72 -727.89
F6 NW APARTMENT 07-MAR-14:00 4370.94 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -629.72 0.00 -3604.73 -585.37
F6 SE APARTMENT 07-MAR-14:00 4062.23 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -387.26 0.00 -3604.73 -519.12
F6 NE APARTMENT 07-MAR-14:00 4339.01 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -809.52 0.00 -3604.75 -373.62
F6 N1 APARTMENT 07-MAR-14:00 2517.96 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -497.38 0.00 -2174.30 -295.16
F6 N2 APARTMENT 07-MAR-14:00 2514.70 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -497.48 0.00 -2174.30 -291.80
F6 S1 APARTMENT 07-MAR-14:00 2247.40 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -69.17 0.00 -2174.28 -452.82
F6 S2 APARTMENT 07-MAR-14:00 2244.50 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -69.28 0.00 -2174.28 -449.82
F7 SW APARTMENT 07-MAR-14:00 4319.87 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -216.08 0.00 -3811.60 -741.06
F7 NW APARTMENT 07-MAR-14:00 4600.02 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -638.48 0.00 -3811.61 -598.80
F7 SE APARTMENT 07-MAR-14:00 4290.69 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -395.17 0.00 -3811.61 -532.79
F7 NE APARTMENT 07-MAR-14:00 4567.96 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -817.60 0.00 -3811.64 -387.60
F7 N1 APARTMENT 07-MAR-14:00 2661.21 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -502.29 0.00 -2299.08 -308.71
F7 N2 APARTMENT 07-MAR-14:00 2657.95 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -502.39 0.00 -2299.08 -305.35
F7 S1 APARTMENT 07-MAR-14:00 2389.73 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -73.87 0.00 -2299.06 -465.68
F7 S2 APARTMENT 07-MAR-14:00 2386.80 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -73.97 0.00 -2299.06 -462.64
F8 SW APARTMENT 07-MAR-14:00 4534.61 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -223.16 0.00 -3998.63 -761.70
F8 NW APARTMENT 07-MAR-14:00 4814.16 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -645.69 0.00 -3998.64 -618.71
F8 SE APARTMENT 07-MAR-14:00 4505.00 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -401.66 0.00 -3998.63 -553.58
F8 NE APARTMENT 07-MAR-14:00 4781.78 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -824.23 0.00 -3998.66 -407.76
F8 N1 APARTMENT 07-MAR-14:00 2798.15 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -506.29 0.00 -2411.89 -328.84
F8 N2 APARTMENT 07-MAR-14:00 2794.88 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -506.39 0.00 -2411.89 -325.47
F8 S1 APARTMENT 07-MAR-14:00 2526.96 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -77.68 0.00 -2411.87 -486.30
F8 S2 APARTMENT 07-MAR-14:00 2523.98 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -77.78 0.00 -2411.87 -483.21
F9 SW APARTMENT 07-MAR-14:00 4811.44 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -226.22 0.00 -4170.07 -864.03
F9 NW APARTMENT 07-MAR-14:00 5095.63 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -648.81 0.00 -4170.08 -725.62
F9 SE APARTMENT 07-MAR-14:00 4777.84 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -404.25 0.00 -4170.07 -652.40
F9 NE APARTMENT 07-MAR-14:00 5059.42 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -826.92 0.00 -4170.10 -511.28
F9 N1 APARTMENT 07-MAR-14:00 3006.12 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -507.64 0.00 -2515.30 -432.06
F9 N2 APARTMENT 07-MAR-14:00 3002.47 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -507.74 0.00 -2515.30 -428.31
F9 S1 APARTMENT 07-MAR-14:00 2727.93 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -78.88 0.00 -2515.28 -582.65
F9 S2 APARTMENT 07-MAR-14:00 2724.50 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -78.98 0.00 -2515.28 -579.12
T SW APARTMENT 07-FEB-02:00 5491.95 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -1624.42 0.00 -3466.04 -838.98
T NW APARTMENT 07-FEB-02:00 5617.48 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -1615.63 0.00 -3466.05 -973.29
T SE APARTMENT 07-FEB-02:00 5462.36 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -1605.01 0.00 -3466.04 -828.80
T NE APARTMENT 07-MAR-14:00 5614.95 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -806.71 0.00 -4328.59 -928.53
T N1 APARTMENT 07-FEB-02:00 3587.80 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -985.19 0.00 -2090.72 -949.39
T N2 APARTMENT 07-FEB-02:00 3586.53 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -985.22 0.00 -2090.72 -948.08
T S1 APARTMENT 07-FEB-02:00 3444.99 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -993.25 0.00 -2090.70 -798.52
T S2 APARTMENT 07-FEB-02:00 3443.35 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -993.30 0.00 -2090.70 -796.84
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 07-MAR-14:00 252474.44 0.00 0.00 0.00 3821.85 9104.94 31440.07 29.62 0.00 0.00 0.00 0.00 -30731.14 0.00 -224157.35 -41982.43



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Sec1.1A-General Information

Data
Weather File Burlington International Ap VT USA TMY3 WMO#=726170
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 7836.48
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.50
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
F2 SW APARTMENT 88.25 88.25 0.00 168.00
F2 NW APARTMENT 88.25 88.25 0.00 168.00
F2 SE APARTMENT 88.25 88.25 0.00 168.00
F2 NE APARTMENT 88.25 88.25 0.00 168.00
F2 N1 APARTMENT 88.25 88.25 0.00 168.00
F2 N2 APARTMENT 88.25 88.25 0.00 168.00
F2 S1 APARTMENT 88.25 88.25 0.00 168.00
F2 S2 APARTMENT 88.25 88.25 0.00 168.00
F3 SW APARTMENT 88.25 88.25 0.00 168.00
F3 NW APARTMENT 88.25 88.25 0.00 168.00
F3 SE APARTMENT 88.25 88.25 0.00 168.00
F3 NE APARTMENT 88.25 88.25 0.00 168.00
F3 N1 APARTMENT 88.25 88.25 0.00 168.00
F3 N2 APARTMENT 88.25 88.25 0.00 168.00
F3 S1 APARTMENT 88.25 88.25 0.00 168.00
F3 S2 APARTMENT 88.25 88.25 0.00 168.00
F4 SW APARTMENT 88.25 88.25 0.00 168.00
F4 NW APARTMENT 88.25 88.25 0.00 168.00
F4 SE APARTMENT 88.25 88.25 0.00 168.00
F4 NE APARTMENT 88.25 88.25 0.00 168.00
F4 N1 APARTMENT 88.25 88.25 0.00 168.00
F4 N2 APARTMENT 88.25 88.25 0.00 168.00
F4 S1 APARTMENT 88.25 88.25 0.00 168.00
F4 S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
F6 SW APARTMENT 88.25 88.25 0.00 168.00
F6 NW APARTMENT 88.25 88.25 0.00 168.00
F6 SE APARTMENT 88.25 88.25 0.00 168.00
F6 NE APARTMENT 88.25 88.25 0.00 168.00
F6 N1 APARTMENT 88.25 88.25 0.00 168.00
F6 N2 APARTMENT 88.25 88.25 0.00 168.00
F6 S1 APARTMENT 88.25 88.25 0.00 168.00
F6 S2 APARTMENT 88.25 88.25 0.00 168.00
F7 SW APARTMENT 88.25 88.25 0.00 168.00
F7 NW APARTMENT 88.25 88.25 0.00 168.00
F7 SE APARTMENT 88.25 88.25 0.00 168.00
F7 NE APARTMENT 88.25 88.25 0.00 168.00
F7 N1 APARTMENT 88.25 88.25 0.00 168.00
F7 N2 APARTMENT 88.25 88.25 0.00 168.00
F7 S1 APARTMENT 88.25 88.25 0.00 168.00
F7 S2 APARTMENT 88.25 88.25 0.00 168.00
F8 SW APARTMENT 88.25 88.25 0.00 168.00
F8 NW APARTMENT 88.25 88.25 0.00 168.00
F8 SE APARTMENT 88.25 88.25 0.00 168.00
F8 NE APARTMENT 88.25 88.25 0.00 168.00
F8 N1 APARTMENT 88.25 88.25 0.00 168.00
F8 N2 APARTMENT 88.25 88.25 0.00 168.00
F8 S1 APARTMENT 88.25 88.25 0.00 168.00
F8 S2 APARTMENT 88.25 88.25 0.00 168.00
F9 SW APARTMENT 88.25 88.25 0.00 168.00
F9 NW APARTMENT 88.25 88.25 0.00 168.00
F9 SE APARTMENT 88.25 88.25 0.00 168.00
F9 NE APARTMENT 88.25 88.25 0.00 168.00
F9 N1 APARTMENT 88.25 88.25 0.00 168.00
F9 N2 APARTMENT 88.25 88.25 0.00 168.00
F9 S1 APARTMENT 88.25 88.25 0.00 168.00
F9 S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
G CORRIDOR 77.66 0.00 77.66 0.00
F2 CORRIDOR 77.66 0.00 77.66 0.00
F3 CORRIDOR 77.66 0.00 77.66 0.00
F4 CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
F6 CORRIDOR 77.66 0.00 77.66 0.00
F7 CORRIDOR 77.66 0.00 77.66 0.00
F8 CORRIDOR 77.66 0.00 77.66 0.00
F9 CORRIDOR 77.66 0.00 77.66 0.00
T CORRIDOR 77.66 0.00 77.66 0.00
Totals 7836.48 7059.89 776.58  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 120.25
Number of hours cooling loads not met 100.50
Number of hours not met 220.75


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 296.56 11327.17 0.00 0.00 0.00 0.00
Exterior Lighting 162.69 10364.00 0.00 0.00 0.00 0.00
Space Heating 402.19 87652.69 1558.07 287983.24 0.00 0.00
Space Cooling 230.30 0.00 0.00 0.00 0.00 0.00
Pumps 64.33 2079.88 0.00 0.00 0.00 0.00
Heat Rejection 10.13 0.00 0.00 0.00 0.00 0.00
Fans-Interior 605.54 19201.55 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 0.00 0.00 1241.86 84624.48 0.00 0.00
Receptacle Equipment 1137.32 57142.09 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 2945.25   2799.92   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 1137.32 2945.25
Natural Gas 0.00 2799.92
Additional 0.00 0.00
Total 1137.32 5745.17


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 37.84
Space Heating 51.32
Space Cooling 29.39
Fans-Interior 77.27
Service Water Heating 0.00
Receptacle Equipment 145.13
Miscellaneous 34.88
Subtotal 375.84


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 198.82
Service Water Heating 158.47
Miscellaneous 0.00
Subtotal 357.29


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 5.16
Space Heating 34.12
Space Cooling 4.01
Fans-Interior 10.54
Service Water Heating 21.62
Receptacle Equipment 19.80
Miscellaneous 4.76



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.208526
G NW APARTMENT DIRECT AIR 0.187195
OFFICE DIRECT AIR 0.325790
G NE APARTMENT DIRECT AIR 0.156235
G N1 APARTMENT DIRECT AIR 0.106987
G N2 APARTMENT DIRECT AIR 0.106982
G S1 APARTMENT DIRECT AIR 0.132893
G S2 APARTMENT DIRECT AIR 0.139184
F2 SW APARTMENT DIRECT AIR 0.274797
F2 NW APARTMENT DIRECT AIR 0.247392
F2 SE APARTMENT DIRECT AIR 0.270610
F2 NE APARTMENT DIRECT AIR 0.187579
F2 N1 APARTMENT DIRECT AIR 0.131032
F2 N2 APARTMENT DIRECT AIR 0.129668
F2 S1 APARTMENT DIRECT AIR 0.180117
F2 S2 APARTMENT DIRECT AIR 0.182448
F3 SW APARTMENT DIRECT AIR 0.277518
F3 NW APARTMENT DIRECT AIR 0.250925
F3 SE APARTMENT DIRECT AIR 0.253027
F3 NE APARTMENT DIRECT AIR 0.191133
F3 N1 APARTMENT DIRECT AIR 0.135403
F3 N2 APARTMENT DIRECT AIR 0.134050
F3 S1 APARTMENT DIRECT AIR 0.184298
F3 S2 APARTMENT DIRECT AIR 0.185361
F4 SW APARTMENT DIRECT AIR 0.279105
F4 NW APARTMENT DIRECT AIR 0.252601
F4 SE APARTMENT DIRECT AIR 0.252608
F4 NE APARTMENT DIRECT AIR 0.192054
F4 N1 APARTMENT DIRECT AIR 0.137112
F4 N2 APARTMENT DIRECT AIR 0.135761
F4 S1 APARTMENT DIRECT AIR 0.185778
F4 S2 APARTMENT DIRECT AIR 0.186655
M SW APARTMENT DIRECT AIR 0.282299
M NW APARTMENT DIRECT AIR 0.255888
M SE APARTMENT DIRECT AIR 0.255585
M NE APARTMENT DIRECT AIR 0.194673
M N1 APARTMENT DIRECT AIR 0.140259
M N2 APARTMENT DIRECT AIR 0.138910
M S1 APARTMENT DIRECT AIR 0.188767
M S2 APARTMENT DIRECT AIR 0.189614
F6 SW APARTMENT DIRECT AIR 0.279770
F6 NW APARTMENT DIRECT AIR 0.253311
F6 SE APARTMENT DIRECT AIR 0.253102
F6 NE APARTMENT DIRECT AIR 0.191641
F6 N1 APARTMENT DIRECT AIR 0.137843
F6 N2 APARTMENT DIRECT AIR 0.136502
F6 S1 APARTMENT DIRECT AIR 0.186143
F6 S2 APARTMENT DIRECT AIR 0.186985
F7 SW APARTMENT DIRECT AIR 0.279239
F7 NW APARTMENT DIRECT AIR 0.252800
F7 SE APARTMENT DIRECT AIR 0.252628
F7 NE APARTMENT DIRECT AIR 0.190689
F7 N1 APARTMENT DIRECT AIR 0.137373
F7 N2 APARTMENT DIRECT AIR 0.136039
F7 S1 APARTMENT DIRECT AIR 0.185489
F7 S2 APARTMENT DIRECT AIR 0.186327
F8 SW APARTMENT DIRECT AIR 0.279858
F8 NW APARTMENT DIRECT AIR 0.253479
F8 SE APARTMENT DIRECT AIR 0.253274
F8 NE APARTMENT DIRECT AIR 0.190880
F8 N1 APARTMENT DIRECT AIR 0.138093
F8 N2 APARTMENT DIRECT AIR 0.136766
F8 S1 APARTMENT DIRECT AIR 0.185967
F8 S2 APARTMENT DIRECT AIR 0.186805
F9 SW APARTMENT DIRECT AIR 0.288623
F9 NW APARTMENT DIRECT AIR 0.262511
F9 SE APARTMENT DIRECT AIR 0.260045
F9 NE APARTMENT DIRECT AIR 0.194166
F9 N1 APARTMENT DIRECT AIR 0.145883
F9 N2 APARTMENT DIRECT AIR 0.144530
F9 S1 APARTMENT DIRECT AIR 0.191581
F9 S2 APARTMENT DIRECT AIR 0.192406
T SW APARTMENT DIRECT AIR 0.357686
T NW APARTMENT DIRECT AIR 0.318351
T SE APARTMENT DIRECT AIR 0.322787
T NE APARTMENT DIRECT AIR 0.242581
T N1 APARTMENT DIRECT AIR 0.186653
T N2 APARTMENT DIRECT AIR 0.186451
T S1 APARTMENT DIRECT AIR 0.264114
T S2 APARTMENT DIRECT AIR 0.264908


Branch

Maximum Flow Rate [m3/s]
AIRLOOP G SW MAIN BRANCH 0.208526
AIRLOOP G NW MAIN BRANCH 0.187195
AIRLOOP OFFICE MAIN BRANCH 0.325790
AIRLOOP G NE MAIN BRANCH 0.156235
AIRLOOP G N1 MAIN BRANCH 0.106987
AIRLOOP G N2 MAIN BRANCH 0.106982
AIRLOOP G S1 MAIN BRANCH 0.132893
AIRLOOP G S2 MAIN BRANCH 0.139184
AIRLOOP F2 SW MAIN BRANCH 0.274797
AIRLOOP F2 NW MAIN BRANCH 0.247392
AIRLOOP F2 SE MAIN BRANCH 0.270610
AIRLOOP F2 NE MAIN BRANCH 0.187579
AIRLOOP F2 N1 MAIN BRANCH 0.131032
AIRLOOP F2 N2 MAIN BRANCH 0.129668
AIRLOOP F2 S1 MAIN BRANCH 0.180117
AIRLOOP F2 S2 MAIN BRANCH 0.182448
AIRLOOP F3 SW MAIN BRANCH 0.277518
AIRLOOP F3 NW MAIN BRANCH 0.250925
AIRLOOP F3 SE MAIN BRANCH 0.253027
AIRLOOP F3 NE MAIN BRANCH 0.191133
AIRLOOP F3 N1 MAIN BRANCH 0.135403
AIRLOOP F3 N2 MAIN BRANCH 0.134050
AIRLOOP F3 S1 MAIN BRANCH 0.184298
AIRLOOP F3 S2 MAIN BRANCH 0.185361
AIRLOOP F4 SW MAIN BRANCH 0.279105
AIRLOOP F4 NW MAIN BRANCH 0.252601
AIRLOOP F4 SE MAIN BRANCH 0.252608
AIRLOOP F4 NE MAIN BRANCH 0.192054
AIRLOOP F4 N1 MAIN BRANCH 0.137112
AIRLOOP F4 N2 MAIN BRANCH 0.135761
AIRLOOP F4 S1 MAIN BRANCH 0.185778
AIRLOOP F4 S2 MAIN BRANCH 0.186655
AIRLOOP M SW MAIN BRANCH 0.282299
AIRLOOP M NW MAIN BRANCH 0.255888
AIRLOOP M SE MAIN BRANCH 0.255585
AIRLOOP M NE MAIN BRANCH 0.194673
AIRLOOP M N1 MAIN BRANCH 0.140259
AIRLOOP M N2 MAIN BRANCH 0.138910
AIRLOOP M S1 MAIN BRANCH 0.188767
AIRLOOP M S2 MAIN BRANCH 0.189614
AIRLOOP F6 SW MAIN BRANCH 0.279770
AIRLOOP F6 NW MAIN BRANCH 0.253311
AIRLOOP F6 SE MAIN BRANCH 0.253102
AIRLOOP F6 NE MAIN BRANCH 0.191641
AIRLOOP F6 N1 MAIN BRANCH 0.137843
AIRLOOP F6 N2 MAIN BRANCH 0.136502
AIRLOOP F6 S1 MAIN BRANCH 0.186143
AIRLOOP F6 S2 MAIN BRANCH 0.186985
AIRLOOP F7 SW MAIN BRANCH 0.279239
AIRLOOP F7 NW MAIN BRANCH 0.252800
AIRLOOP F7 SE MAIN BRANCH 0.252628
AIRLOOP F7 NE MAIN BRANCH 0.190689
AIRLOOP F7 N1 MAIN BRANCH 0.137373
AIRLOOP F7 N2 MAIN BRANCH 0.136039
AIRLOOP F7 S1 MAIN BRANCH 0.185489
AIRLOOP F7 S2 MAIN BRANCH 0.186327
AIRLOOP F8 SW MAIN BRANCH 0.279858
AIRLOOP F8 NW MAIN BRANCH 0.253479
AIRLOOP F8 SE MAIN BRANCH 0.253274
AIRLOOP F8 NE MAIN BRANCH 0.190880
AIRLOOP F8 N1 MAIN BRANCH 0.138093
AIRLOOP F8 N2 MAIN BRANCH 0.136766
AIRLOOP F8 S1 MAIN BRANCH 0.185967
AIRLOOP F8 S2 MAIN BRANCH 0.186805
AIRLOOP F9 SW MAIN BRANCH 0.288623
AIRLOOP F9 NW MAIN BRANCH 0.262511
AIRLOOP F9 SE MAIN BRANCH 0.260045
AIRLOOP F9 NE MAIN BRANCH 0.194166
AIRLOOP F9 N1 MAIN BRANCH 0.145883
AIRLOOP F9 N2 MAIN BRANCH 0.144530
AIRLOOP F9 S1 MAIN BRANCH 0.191581
AIRLOOP F9 S2 MAIN BRANCH 0.192406
AIRLOOP T SW MAIN BRANCH 0.357686
AIRLOOP T NW MAIN BRANCH 0.318351
AIRLOOP T SE MAIN BRANCH 0.322787
AIRLOOP T NE MAIN BRANCH 0.242581
AIRLOOP T N1 MAIN BRANCH 0.186653
AIRLOOP T N2 MAIN BRANCH 0.186451
AIRLOOP T S1 MAIN BRANCH 0.264114
AIRLOOP T S2 MAIN BRANCH 0.264908


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
AIRLOOP G SW 0.208526
AIRLOOP G NW 0.187195
AIRLOOP OFFICE 0.325790
AIRLOOP G NE 0.156235
AIRLOOP G N1 0.106987
AIRLOOP G N2 0.106982
AIRLOOP G S1 0.132893
AIRLOOP G S2 0.139184
AIRLOOP F2 SW 0.274797
AIRLOOP F2 NW 0.247392
AIRLOOP F2 SE 0.270610
AIRLOOP F2 NE 0.187579
AIRLOOP F2 N1 0.131032
AIRLOOP F2 N2 0.129668
AIRLOOP F2 S1 0.180117
AIRLOOP F2 S2 0.182448
AIRLOOP F3 SW 0.277518
AIRLOOP F3 NW 0.250925
AIRLOOP F3 SE 0.253027
AIRLOOP F3 NE 0.191133
AIRLOOP F3 N1 0.135403
AIRLOOP F3 N2 0.134050
AIRLOOP F3 S1 0.184298
AIRLOOP F3 S2 0.185361
AIRLOOP F4 SW 0.279105
AIRLOOP F4 NW 0.252601
AIRLOOP F4 SE 0.252608
AIRLOOP F4 NE 0.192054
AIRLOOP F4 N1 0.137112
AIRLOOP F4 N2 0.135761
AIRLOOP F4 S1 0.185778
AIRLOOP F4 S2 0.186655
AIRLOOP M SW 0.282299
AIRLOOP M NW 0.255888
AIRLOOP M SE 0.255585
AIRLOOP M NE 0.194673
AIRLOOP M N1 0.140259
AIRLOOP M N2 0.138910
AIRLOOP M S1 0.188767
AIRLOOP M S2 0.189614
AIRLOOP F6 SW 0.279770
AIRLOOP F6 NW 0.253311
AIRLOOP F6 SE 0.253102
AIRLOOP F6 NE 0.191641
AIRLOOP F6 N1 0.137843
AIRLOOP F6 N2 0.136502
AIRLOOP F6 S1 0.186143
AIRLOOP F6 S2 0.186985
AIRLOOP F7 SW 0.279239
AIRLOOP F7 NW 0.252800
AIRLOOP F7 SE 0.252628
AIRLOOP F7 NE 0.190689
AIRLOOP F7 N1 0.137373
AIRLOOP F7 N2 0.136039
AIRLOOP F7 S1 0.185489
AIRLOOP F7 S2 0.186327
AIRLOOP F8 SW 0.279858
AIRLOOP F8 NW 0.253479
AIRLOOP F8 SE 0.253274
AIRLOOP F8 NE 0.190880
AIRLOOP F8 N1 0.138093
AIRLOOP F8 N2 0.136766
AIRLOOP F8 S1 0.185967
AIRLOOP F8 S2 0.186805
AIRLOOP F9 SW 0.288623
AIRLOOP F9 NW 0.262511
AIRLOOP F9 SE 0.260045
AIRLOOP F9 NE 0.194166
AIRLOOP F9 N1 0.145883
AIRLOOP F9 N2 0.144530
AIRLOOP F9 S1 0.191581
AIRLOOP F9 S2 0.192406
AIRLOOP T SW 0.357686
AIRLOOP T NW 0.318351
AIRLOOP T SE 0.322787
AIRLOOP T NE 0.242581
AIRLOOP T N1 0.186653
AIRLOOP T N2 0.186451
AIRLOOP T S1 0.264114
AIRLOOP T S2 0.264908


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
AIRLOOP G SW OA CONTROLLER 0.208526 0.025952
AIRLOOP G NW OA CONTROLLER 0.187195 0.025952
AIRLOOP OFFICE OA CONTROLLER 0.325790 0.038103
AIRLOOP G NE OA CONTROLLER 0.156235 0.025952
AIRLOOP G N1 OA CONTROLLER 0.106987 0.025952
AIRLOOP G N2 OA CONTROLLER 0.106982 0.025952
AIRLOOP G S1 OA CONTROLLER 0.132893 0.025952
AIRLOOP G S2 OA CONTROLLER 0.139184 0.025952
AIRLOOP F2 SW OA CONTROLLER 0.274797 0.025952
AIRLOOP F2 NW OA CONTROLLER 0.247392 0.025952
AIRLOOP F2 SE OA CONTROLLER 0.270610 0.025952
AIRLOOP F2 NE OA CONTROLLER 0.187579 0.025952
AIRLOOP F2 N1 OA CONTROLLER 0.131032 0.025952
AIRLOOP F2 N2 OA CONTROLLER 0.129668 0.025952
AIRLOOP F2 S1 OA CONTROLLER 0.180117 0.025952
AIRLOOP F2 S2 OA CONTROLLER 0.182448 0.025952
AIRLOOP F3 SW OA CONTROLLER 0.277518 0.025952
AIRLOOP F3 NW OA CONTROLLER 0.250925 0.025952
AIRLOOP F3 SE OA CONTROLLER 0.253027 0.025952
AIRLOOP F3 NE OA CONTROLLER 0.191133 0.025952
AIRLOOP F3 N1 OA CONTROLLER 0.135403 0.025952
AIRLOOP F3 N2 OA CONTROLLER 0.134050 0.025952
AIRLOOP F3 S1 OA CONTROLLER 0.184298 0.025952
AIRLOOP F3 S2 OA CONTROLLER 0.185361 0.025952
AIRLOOP F4 SW OA CONTROLLER 0.279105 0.025952
AIRLOOP F4 NW OA CONTROLLER 0.252601 0.025952
AIRLOOP F4 SE OA CONTROLLER 0.252608 0.025952
AIRLOOP F4 NE OA CONTROLLER 0.192054 0.025952
AIRLOOP F4 N1 OA CONTROLLER 0.137112 0.025952
AIRLOOP F4 N2 OA CONTROLLER 0.135761 0.025952
AIRLOOP F4 S1 OA CONTROLLER 0.185778 0.025952
AIRLOOP F4 S2 OA CONTROLLER 0.186655 0.025952
AIRLOOP M SW OA CONTROLLER 0.282299 0.025952
AIRLOOP M NW OA CONTROLLER 0.255888 0.025952
AIRLOOP M SE OA CONTROLLER 0.255585 0.025952
AIRLOOP M NE OA CONTROLLER 0.194673 0.025952
AIRLOOP M N1 OA CONTROLLER 0.140259 0.025952
AIRLOOP M N2 OA CONTROLLER 0.138910 0.025952
AIRLOOP M S1 OA CONTROLLER 0.188767 0.025952
AIRLOOP M S2 OA CONTROLLER 0.189614 0.025952
AIRLOOP F6 SW OA CONTROLLER 0.279770 0.025952
AIRLOOP F6 NW OA CONTROLLER 0.253311 0.025952
AIRLOOP F6 SE OA CONTROLLER 0.253102 0.025952
AIRLOOP F6 NE OA CONTROLLER 0.191641 0.025952
AIRLOOP F6 N1 OA CONTROLLER 0.137843 0.025952
AIRLOOP F6 N2 OA CONTROLLER 0.136502 0.025952
AIRLOOP F6 S1 OA CONTROLLER 0.186143 0.025952
AIRLOOP F6 S2 OA CONTROLLER 0.186985 0.025952
AIRLOOP F7 SW OA CONTROLLER 0.279239 0.025952
AIRLOOP F7 NW OA CONTROLLER 0.252800 0.025952
AIRLOOP F7 SE OA CONTROLLER 0.252628 0.025952
AIRLOOP F7 NE OA CONTROLLER 0.190689 0.025952
AIRLOOP F7 N1 OA CONTROLLER 0.137373 0.025952
AIRLOOP F7 N2 OA CONTROLLER 0.136039 0.025952
AIRLOOP F7 S1 OA CONTROLLER 0.185489 0.025952
AIRLOOP F7 S2 OA CONTROLLER 0.186327 0.025952
AIRLOOP F8 SW OA CONTROLLER 0.279858 0.025952
AIRLOOP F8 NW OA CONTROLLER 0.253479 0.025952
AIRLOOP F8 SE OA CONTROLLER 0.253274 0.025952
AIRLOOP F8 NE OA CONTROLLER 0.190880 0.025952
AIRLOOP F8 N1 OA CONTROLLER 0.138093 0.025952
AIRLOOP F8 N2 OA CONTROLLER 0.136766 0.025952
AIRLOOP F8 S1 OA CONTROLLER 0.185967 0.025952
AIRLOOP F8 S2 OA CONTROLLER 0.186805 0.025952
AIRLOOP F9 SW OA CONTROLLER 0.288623 0.025952
AIRLOOP F9 NW OA CONTROLLER 0.262511 0.025952
AIRLOOP F9 SE OA CONTROLLER 0.260045 0.025952
AIRLOOP F9 NE OA CONTROLLER 0.194166 0.025952
AIRLOOP F9 N1 OA CONTROLLER 0.145883 0.025952
AIRLOOP F9 N2 OA CONTROLLER 0.144530 0.025952
AIRLOOP F9 S1 OA CONTROLLER 0.191581 0.025952
AIRLOOP F9 S2 OA CONTROLLER 0.192406 0.025952
AIRLOOP T SW OA CONTROLLER 0.357686 0.025952
AIRLOOP T NW OA CONTROLLER 0.318351 0.025952
AIRLOOP T SE OA CONTROLLER 0.322787 0.025952
AIRLOOP T NE OA CONTROLLER 0.242581 0.025952
AIRLOOP T N1 OA CONTROLLER 0.186653 0.025952
AIRLOOP T N2 OA CONTROLLER 0.186451 0.025952
AIRLOOP T S1 OA CONTROLLER 0.264114 0.025952
AIRLOOP T S2 OA CONTROLLER 0.264908 0.025952


COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity [W] Rated Sensible Cooling Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP COOLING MODE AIRLOOP G SW 0.208526 3615.89 2481.30 0.000079
HEAT PUMP COOLING MODE AIRLOOP G NW 0.187195 3274.33 2230.09 0.000072
HEAT PUMP COOLING MODE AIRLOOP OFFICE 0.325790 5487.24 3826.54 0.000120
HEAT PUMP COOLING MODE AIRLOOP G NE 0.156235 2865.06 1896.97 0.000063
HEAT PUMP COOLING MODE AIRLOOP G N1 0.106987 2114.52 1356.97 0.000046
HEAT PUMP COOLING MODE AIRLOOP G N2 0.106982 2123.52 1360.25 0.000046
HEAT PUMP COOLING MODE AIRLOOP G S1 0.132893 2486.75 1648.50 0.000054
HEAT PUMP COOLING MODE AIRLOOP G S2 0.139184 2576.07 1716.41 0.000056
HEAT PUMP COOLING MODE AIRLOOP F2 SW 0.274797 4609.02 3210.05 0.000101
HEAT PUMP COOLING MODE AIRLOOP F2 NW 0.247392 4198.77 2900.91 0.000092
HEAT PUMP COOLING MODE AIRLOOP F2 SE 0.270610 4567.41 3173.61 0.000100
HEAT PUMP COOLING MODE AIRLOOP F2 NE 0.187579 3291.40 2228.56 0.000072
HEAT PUMP COOLING MODE AIRLOOP F2 N1 0.131032 2426.09 1602.37 0.000053
HEAT PUMP COOLING MODE AIRLOOP F2 N2 0.129668 2406.11 1587.54 0.000053
HEAT PUMP COOLING MODE AIRLOOP F2 S1 0.180117 3198.48 2171.12 0.000070
HEAT PUMP COOLING MODE AIRLOOP F2 S2 0.182448 3231.48 2196.27 0.000071
HEAT PUMP COOLING MODE AIRLOOP F3 SW 0.277518 4689.66 3251.77 0.000102
HEAT PUMP COOLING MODE AIRLOOP F3 NW 0.250925 4289.48 2951.12 0.000094
HEAT PUMP COOLING MODE AIRLOOP F3 SE 0.253027 4359.19 2995.77 0.000095
HEAT PUMP COOLING MODE AIRLOOP F3 NE 0.191133 3387.18 2282.92 0.000074
HEAT PUMP COOLING MODE AIRLOOP F3 N1 0.135403 2510.47 1656.44 0.000055
HEAT PUMP COOLING MODE AIRLOOP F3 N2 0.134050 2490.59 1641.71 0.000054
HEAT PUMP COOLING MODE AIRLOOP F3 S1 0.184298 3281.95 2223.57 0.000072
HEAT PUMP COOLING MODE AIRLOOP F3 S2 0.185361 3296.98 2235.04 0.000072
HEAT PUMP COOLING MODE AIRLOOP F4 SW 0.279105 4748.68 3280.84 0.000104
HEAT PUMP COOLING MODE AIRLOOP F4 NW 0.252601 4343.30 2978.20 0.000095
HEAT PUMP COOLING MODE AIRLOOP F4 SE 0.252608 4383.30 3000.22 0.000096
HEAT PUMP COOLING MODE AIRLOOP F4 NE 0.192054 3427.72 2301.36 0.000075
HEAT PUMP COOLING MODE AIRLOOP F4 N1 0.137112 2550.81 1679.95 0.000056
HEAT PUMP COOLING MODE AIRLOOP F4 N2 0.135761 2530.89 1665.22 0.000055
HEAT PUMP COOLING MODE AIRLOOP F4 S1 0.185778 3320.96 2245.02 0.000073
HEAT PUMP COOLING MODE AIRLOOP F4 S2 0.186655 3333.37 2254.48 0.000073
HEAT PUMP COOLING MODE AIRLOOP M SW 0.282299 4819.33 3322.83 0.000105
HEAT PUMP COOLING MODE AIRLOOP M NW 0.255888 4414.47 3021.03 0.000096
HEAT PUMP COOLING MODE AIRLOOP M SE 0.255585 4450.14 3039.74 0.000097
HEAT PUMP COOLING MODE AIRLOOP M NE 0.194673 3487.52 2336.60 0.000076
HEAT PUMP COOLING MODE AIRLOOP M N1 0.140259 2609.34 1718.17 0.000057
HEAT PUMP COOLING MODE AIRLOOP M N2 0.138910 2589.43 1703.46 0.000057
HEAT PUMP COOLING MODE AIRLOOP M S1 0.188767 3378.20 2281.80 0.000074
HEAT PUMP COOLING MODE AIRLOOP M S2 0.189614 3390.20 2290.93 0.000074
HEAT PUMP COOLING MODE AIRLOOP F6 SW 0.279770 4804.55 3301.81 0.000105
HEAT PUMP COOLING MODE AIRLOOP F6 NW 0.253311 4397.84 2999.26 0.000096
HEAT PUMP COOLING MODE AIRLOOP F6 SE 0.253102 4435.03 3019.02 0.000097
HEAT PUMP COOLING MODE AIRLOOP F6 NE 0.191641 3461.88 2309.49 0.000076
HEAT PUMP COOLING MODE AIRLOOP F6 N1 0.137843 2584.31 1695.28 0.000056
HEAT PUMP COOLING MODE AIRLOOP F6 N2 0.136502 2564.43 1680.65 0.000056
HEAT PUMP COOLING MODE AIRLOOP F6 S1 0.186143 3352.94 2257.15 0.000073
HEAT PUMP COOLING MODE AIRLOOP F6 S2 0.186985 3364.87 2266.22 0.000074
HEAT PUMP COOLING MODE AIRLOOP F7 SW 0.279239 4815.47 3301.59 0.000105
HEAT PUMP COOLING MODE AIRLOOP F7 NW 0.252800 4408.15 2999.08 0.000096
HEAT PUMP COOLING MODE AIRLOOP F7 SE 0.252628 4448.89 3020.82 0.000097
HEAT PUMP COOLING MODE AIRLOOP F7 NE 0.190689 3463.85 2304.16 0.000076
HEAT PUMP COOLING MODE AIRLOOP F7 N1 0.137373 2586.42 1693.12 0.000056
HEAT PUMP COOLING MODE AIRLOOP F7 N2 0.136039 2566.57 1678.54 0.000056
HEAT PUMP COOLING MODE AIRLOOP F7 S1 0.185489 3354.25 2253.34 0.000073
HEAT PUMP COOLING MODE AIRLOOP F7 S2 0.186327 3366.15 2262.39 0.000074
HEAT PUMP COOLING MODE AIRLOOP F8 SW 0.279858 4840.81 3313.23 0.000106
HEAT PUMP COOLING MODE AIRLOOP F8 NW 0.253479 4433.65 3011.23 0.000097
HEAT PUMP COOLING MODE AIRLOOP F8 SE 0.253274 4473.98 3032.63 0.000098
HEAT PUMP COOLING MODE AIRLOOP F8 NE 0.190880 3480.66 2310.70 0.000076
HEAT PUMP COOLING MODE AIRLOOP F8 N1 0.138093 2605.10 1703.60 0.000057
HEAT PUMP COOLING MODE AIRLOOP F8 N2 0.136766 2585.31 1689.08 0.000056
HEAT PUMP COOLING MODE AIRLOOP F8 S1 0.185967 3370.65 2261.47 0.000074
HEAT PUMP COOLING MODE AIRLOOP F8 S2 0.186805 3382.56 2270.50 0.000074
HEAT PUMP COOLING MODE AIRLOOP F9 SW 0.288623 4976.17 3409.99 0.000109
HEAT PUMP COOLING MODE AIRLOOP F9 NW 0.262511 4578.53 3113.66 0.000100
HEAT PUMP COOLING MODE AIRLOOP F9 SE 0.260045 4586.19 3110.55 0.000100
HEAT PUMP COOLING MODE AIRLOOP F9 NE 0.194166 3550.26 2355.27 0.000078
HEAT PUMP COOLING MODE AIRLOOP F9 N1 0.145883 2727.79 1790.96 0.000060
HEAT PUMP COOLING MODE AIRLOOP F9 N2 0.144530 2707.68 1776.18 0.000059
HEAT PUMP COOLING MODE AIRLOOP F9 S1 0.191581 3463.06 2326.54 0.000076
HEAT PUMP COOLING MODE AIRLOOP F9 S2 0.192406 3474.79 2335.45 0.000076
HEAT PUMP COOLING MODE AIRLOOP T SW 0.357686 5999.32 4173.57 0.000131
HEAT PUMP COOLING MODE AIRLOOP T NW 0.318351 5415.59 3736.12 0.000118
HEAT PUMP COOLING MODE AIRLOOP T SE 0.322787 5496.21 3792.90 0.000120
HEAT PUMP COOLING MODE AIRLOOP T NE 0.242581 4353.25 2928.18 0.000095
HEAT PUMP COOLING MODE AIRLOOP T N1 0.186653 3402.57 2276.94 0.000074
HEAT PUMP COOLING MODE AIRLOOP T N2 0.186451 3399.99 2274.85 0.000074
HEAT PUMP COOLING MODE AIRLOOP T S1 0.264114 4504.17 3112.60 0.000098
HEAT PUMP COOLING MODE AIRLOOP T S2 0.264908 4515.29 3121.14 0.000099


AirLoopHVAC:UnitaryHeatPump:WaterToAir

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Supplemental Heating Coil Nominal Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
AIRLOOP G SW DXAC HEAT PUMP 0.208526 0.208526 0.208526 0.208526 3615.89 3615.89 4791.42 1.00
AIRLOOP G NW DXAC HEAT PUMP 0.187195 0.187195 0.187195 0.187195 3274.33 3274.33 4792.71 1.00
AIRLOOP OFFICE DXAC HEAT PUMP 0.325790 0.325790 0.325790 0.325790 5487.24 5487.24 5842.94 1.00
AIRLOOP G NE DXAC HEAT PUMP 0.156235 0.156235 0.156235 0.156235 2865.06 2865.06 4787.47 1.00
AIRLOOP G N1 DXAC HEAT PUMP 0.106987 0.106987 0.106987 0.106987 2114.52 2114.52 3709.69 1.00
AIRLOOP G N2 DXAC HEAT PUMP 0.106982 0.106982 0.106982 0.106982 2123.52 2123.52 3709.57 1.00
AIRLOOP G S1 DXAC HEAT PUMP 0.132893 0.132893 0.132893 0.132893 2486.75 2486.75 3705.85 1.00
AIRLOOP G S2 DXAC HEAT PUMP 0.139184 0.139184 0.139184 0.139184 2576.07 2576.07 3712.01 1.00
AIRLOOP F2 SW DXAC HEAT PUMP 0.274797 0.274797 0.274797 0.274797 4609.02 4609.02 4635.62 1.00
AIRLOOP F2 NW DXAC HEAT PUMP 0.247392 0.247392 0.247392 0.247392 4198.77 4198.77 4629.05 1.00
AIRLOOP F2 SE DXAC HEAT PUMP 0.270610 0.270610 0.270610 0.270610 4567.41 4567.41 4650.10 1.00
AIRLOOP F2 NE DXAC HEAT PUMP 0.187579 0.187579 0.187579 0.187579 3291.40 3291.40 4625.42 1.00
AIRLOOP F2 N1 DXAC HEAT PUMP 0.131032 0.131032 0.131032 0.131032 2426.09 2426.09 3290.66 1.00
AIRLOOP F2 N2 DXAC HEAT PUMP 0.129668 0.129668 0.129668 0.129668 2406.11 2406.11 3290.58 1.00
AIRLOOP F2 S1 DXAC HEAT PUMP 0.180117 0.180117 0.180117 0.180117 3198.48 3198.48 3300.33 1.00
AIRLOOP F2 S2 DXAC HEAT PUMP 0.182448 0.182448 0.182448 0.182448 3231.48 3231.48 3301.36 1.00
AIRLOOP F3 SW DXAC HEAT PUMP 0.277518 0.277518 0.277518 0.277518 4689.66 4689.66 4687.04 1.00
AIRLOOP F3 NW DXAC HEAT PUMP 0.250925 0.250925 0.250925 0.250925 4289.48 4289.48 4685.82 1.00
AIRLOOP F3 SE DXAC HEAT PUMP 0.253027 0.253027 0.253027 0.253027 4359.19 4359.19 4687.32 1.00
AIRLOOP F3 NE DXAC HEAT PUMP 0.191133 0.191133 0.191133 0.191133 3387.18 3387.18 4684.26 1.00
AIRLOOP F3 N1 DXAC HEAT PUMP 0.135403 0.135403 0.135403 0.135403 2510.47 2510.47 3270.88 1.00
AIRLOOP F3 N2 DXAC HEAT PUMP 0.134050 0.134050 0.134050 0.134050 2490.59 2490.59 3270.85 1.00
AIRLOOP F3 S1 DXAC HEAT PUMP 0.184298 0.184298 0.184298 0.184298 3281.95 3281.95 3273.27 1.00
AIRLOOP F3 S2 DXAC HEAT PUMP 0.185361 0.185361 0.185361 0.185361 3296.98 3296.98 3273.39 1.00
AIRLOOP F4 SW DXAC HEAT PUMP 0.279105 0.279105 0.279105 0.279105 4748.68 4748.68 4808.92 1.00
AIRLOOP F4 NW DXAC HEAT PUMP 0.252601 0.252601 0.252601 0.252601 4343.30 4343.30 4811.12 1.00
AIRLOOP F4 SE DXAC HEAT PUMP 0.252608 0.252608 0.252608 0.252608 4383.30 4383.30 4809.21 1.00
AIRLOOP F4 NE DXAC HEAT PUMP 0.192054 0.192054 0.192054 0.192054 3427.72 3427.72 4811.23 1.00
AIRLOOP F4 N1 DXAC HEAT PUMP 0.137112 0.137112 0.137112 0.137112 2550.81 2550.81 3334.65 1.00
AIRLOOP F4 N2 DXAC HEAT PUMP 0.135761 0.135761 0.135761 0.135761 2530.89 2530.89 3334.66 1.00
AIRLOOP F4 S1 DXAC HEAT PUMP 0.185778 0.185778 0.185778 0.185778 3320.96 3320.96 3333.33 1.00
AIRLOOP F4 S2 DXAC HEAT PUMP 0.186655 0.186655 0.186655 0.186655 3333.37 3333.37 3333.35 1.00
AIRLOOP M SW DXAC HEAT PUMP 0.282299 0.282299 0.282299 0.282299 4819.33 4819.33 4901.86 1.00
AIRLOOP M NW DXAC HEAT PUMP 0.255888 0.255888 0.255888 0.255888 4414.47 4414.47 4905.43 1.00
AIRLOOP M SE DXAC HEAT PUMP 0.255585 0.255585 0.255585 0.255585 4450.14 4450.14 4903.41 1.00
AIRLOOP M NE DXAC HEAT PUMP 0.194673 0.194673 0.194673 0.194673 3487.52 3487.52 4906.96 1.00
AIRLOOP M N1 DXAC HEAT PUMP 0.140259 0.140259 0.140259 0.140259 2609.34 2609.34 3379.84 1.00
AIRLOOP M N2 DXAC HEAT PUMP 0.138910 0.138910 0.138910 0.138910 2589.43 2589.43 3379.87 1.00
AIRLOOP M S1 DXAC HEAT PUMP 0.188767 0.188767 0.188767 0.188767 3378.20 3378.20 3377.05 1.00
AIRLOOP M S2 DXAC HEAT PUMP 0.189614 0.189614 0.189614 0.189614 3390.20 3390.20 3377.08 1.00
AIRLOOP F6 SW DXAC HEAT PUMP 0.279770 0.279770 0.279770 0.279770 4804.55 4804.55 5046.01 1.00
AIRLOOP F6 NW DXAC HEAT PUMP 0.253311 0.253311 0.253311 0.253311 4397.84 4397.84 5052.40 1.00
AIRLOOP F6 SE DXAC HEAT PUMP 0.253102 0.253102 0.253102 0.253102 4435.03 4435.03 5048.77 1.00
AIRLOOP F6 NE DXAC HEAT PUMP 0.191641 0.191641 0.191641 0.191641 3461.88 3461.88 5055.16 1.00
AIRLOOP F6 N1 DXAC HEAT PUMP 0.137843 0.137843 0.137843 0.137843 2584.31 2584.31 3482.67 1.00
AIRLOOP F6 N2 DXAC HEAT PUMP 0.136502 0.136502 0.136502 0.136502 2564.43 2564.43 3482.74 1.00
AIRLOOP F6 S1 DXAC HEAT PUMP 0.186143 0.186143 0.186143 0.186143 3352.94 3352.94 3477.05 1.00
AIRLOOP F6 S2 DXAC HEAT PUMP 0.186985 0.186985 0.186985 0.186985 3364.87 3364.87 3477.11 1.00
AIRLOOP F7 SW DXAC HEAT PUMP 0.279239 0.279239 0.279239 0.279239 4815.47 4815.47 5156.64 1.00
AIRLOOP F7 NW DXAC HEAT PUMP 0.252800 0.252800 0.252800 0.252800 4408.15 4408.15 5164.48 1.00
AIRLOOP F7 SE DXAC HEAT PUMP 0.252628 0.252628 0.252628 0.252628 4448.89 4448.89 5160.47 1.00
AIRLOOP F7 NE DXAC HEAT PUMP 0.190689 0.190689 0.190689 0.190689 3463.85 3463.85 5168.32 1.00
AIRLOOP F7 N1 DXAC HEAT PUMP 0.137373 0.137373 0.137373 0.137373 2586.42 2586.42 3557.01 1.00
AIRLOOP F7 N2 DXAC HEAT PUMP 0.136039 0.136039 0.136039 0.136039 2566.57 2566.57 3557.10 1.00
AIRLOOP F7 S1 DXAC HEAT PUMP 0.185489 0.185489 0.185489 0.185489 3354.25 3354.25 3549.93 1.00
AIRLOOP F7 S2 DXAC HEAT PUMP 0.186327 0.186327 0.186327 0.186327 3366.15 3366.15 3550.02 1.00
AIRLOOP F8 SW DXAC HEAT PUMP 0.279858 0.279858 0.279858 0.279858 4840.81 4840.81 5270.43 1.00
AIRLOOP F8 NW DXAC HEAT PUMP 0.253479 0.253479 0.253479 0.253479 4433.65 4433.65 5279.20 1.00
AIRLOOP F8 SE DXAC HEAT PUMP 0.253274 0.253274 0.253274 0.253274 4473.98 4473.98 5275.22 1.00
AIRLOOP F8 NE DXAC HEAT PUMP 0.190880 0.190880 0.190880 0.190880 3480.66 3480.66 5283.99 1.00
AIRLOOP F8 N1 DXAC HEAT PUMP 0.138093 0.138093 0.138093 0.138093 2605.10 2605.10 3638.12 1.00
AIRLOOP F8 N2 DXAC HEAT PUMP 0.136766 0.136766 0.136766 0.136766 2585.31 2585.31 3638.22 1.00
AIRLOOP F8 S1 DXAC HEAT PUMP 0.185967 0.185967 0.185967 0.185967 3370.65 3370.65 3630.10 1.00
AIRLOOP F8 S2 DXAC HEAT PUMP 0.186805 0.186805 0.186805 0.186805 3382.56 3382.56 3630.21 1.00
AIRLOOP F9 SW DXAC HEAT PUMP 0.288623 0.288623 0.288623 0.288623 4976.17 4976.17 5546.58 1.00
AIRLOOP F9 NW DXAC HEAT PUMP 0.262511 0.262511 0.262511 0.262511 4578.53 4578.53 5553.04 1.00
AIRLOOP F9 SE DXAC HEAT PUMP 0.260045 0.260045 0.260045 0.260045 4586.19 4586.19 5552.28 1.00
AIRLOOP F9 NE DXAC HEAT PUMP 0.194166 0.194166 0.194166 0.194166 3550.26 3550.26 5558.75 1.00
AIRLOOP F9 N1 DXAC HEAT PUMP 0.145883 0.145883 0.145883 0.145883 2727.79 2727.79 3870.79 1.00
AIRLOOP F9 N2 DXAC HEAT PUMP 0.144530 0.144530 0.144530 0.144530 2707.68 2707.68 3870.92 1.00
AIRLOOP F9 S1 DXAC HEAT PUMP 0.191581 0.191581 0.191581 0.191581 3463.06 3463.06 3864.63 1.00
AIRLOOP F9 S2 DXAC HEAT PUMP 0.192406 0.192406 0.192406 0.192406 3474.79 3474.79 3864.76 1.00
AIRLOOP T SW DXAC HEAT PUMP 0.357686 0.357686 0.357686 0.357686 5999.32 5999.32 6473.79 1.00
AIRLOOP T NW DXAC HEAT PUMP 0.318351 0.318351 0.318351 0.318351 5415.59 5415.59 6489.18 1.00
AIRLOOP T SE DXAC HEAT PUMP 0.322787 0.322787 0.322787 0.322787 5496.21 5496.21 6479.78 1.00
AIRLOOP T NE DXAC HEAT PUMP 0.242581 0.242581 0.242581 0.242581 4353.25 4353.25 6495.17 1.00
AIRLOOP T N1 DXAC HEAT PUMP 0.186653 0.186653 0.186653 0.186653 3402.57 3402.57 4848.84 1.00
AIRLOOP T N2 DXAC HEAT PUMP 0.186451 0.186451 0.186451 0.186451 3399.99 3399.99 4848.98 1.00
AIRLOOP T S1 DXAC HEAT PUMP 0.264114 0.264114 0.264114 0.264114 4504.17 4504.17 4830.67 1.00
AIRLOOP T S2 DXAC HEAT PUMP 0.264908 0.264908 0.264908 0.264908 4515.29 4515.29 4830.81 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
AIRLOOP G SW SUPPLY FAN 0.208526
AIRLOOP G NW SUPPLY FAN 0.187195
AIRLOOP OFFICE SUPPLY FAN 0.325790
AIRLOOP G NE SUPPLY FAN 0.156235
AIRLOOP G N1 SUPPLY FAN 0.106987
AIRLOOP G N2 SUPPLY FAN 0.106982
AIRLOOP G S1 SUPPLY FAN 0.132893
AIRLOOP G S2 SUPPLY FAN 0.139184
AIRLOOP F2 SW SUPPLY FAN 0.274797
AIRLOOP F2 NW SUPPLY FAN 0.247392
AIRLOOP F2 SE SUPPLY FAN 0.270610
AIRLOOP F2 NE SUPPLY FAN 0.187579
AIRLOOP F2 N1 SUPPLY FAN 0.131032
AIRLOOP F2 N2 SUPPLY FAN 0.129668
AIRLOOP F2 S1 SUPPLY FAN 0.180117
AIRLOOP F2 S2 SUPPLY FAN 0.182448
AIRLOOP F3 SW SUPPLY FAN 0.277518
AIRLOOP F3 NW SUPPLY FAN 0.250925
AIRLOOP F3 SE SUPPLY FAN 0.253027
AIRLOOP F3 NE SUPPLY FAN 0.191133
AIRLOOP F3 N1 SUPPLY FAN 0.135403
AIRLOOP F3 N2 SUPPLY FAN 0.134050
AIRLOOP F3 S1 SUPPLY FAN 0.184298
AIRLOOP F3 S2 SUPPLY FAN 0.185361
AIRLOOP F4 SW SUPPLY FAN 0.279105
AIRLOOP F4 NW SUPPLY FAN 0.252601
AIRLOOP F4 SE SUPPLY FAN 0.252608
AIRLOOP F4 NE SUPPLY FAN 0.192054
AIRLOOP F4 N1 SUPPLY FAN 0.137112
AIRLOOP F4 N2 SUPPLY FAN 0.135761
AIRLOOP F4 S1 SUPPLY FAN 0.185778
AIRLOOP F4 S2 SUPPLY FAN 0.186655
AIRLOOP M SW SUPPLY FAN 0.282299
AIRLOOP M NW SUPPLY FAN 0.255888
AIRLOOP M SE SUPPLY FAN 0.255585
AIRLOOP M NE SUPPLY FAN 0.194673
AIRLOOP M N1 SUPPLY FAN 0.140259
AIRLOOP M N2 SUPPLY FAN 0.138910
AIRLOOP M S1 SUPPLY FAN 0.188767
AIRLOOP M S2 SUPPLY FAN 0.189614
AIRLOOP F6 SW SUPPLY FAN 0.279770
AIRLOOP F6 NW SUPPLY FAN 0.253311
AIRLOOP F6 SE SUPPLY FAN 0.253102
AIRLOOP F6 NE SUPPLY FAN 0.191641
AIRLOOP F6 N1 SUPPLY FAN 0.137843
AIRLOOP F6 N2 SUPPLY FAN 0.136502
AIRLOOP F6 S1 SUPPLY FAN 0.186143
AIRLOOP F6 S2 SUPPLY FAN 0.186985
AIRLOOP F7 SW SUPPLY FAN 0.279239
AIRLOOP F7 NW SUPPLY FAN 0.252800
AIRLOOP F7 SE SUPPLY FAN 0.252628
AIRLOOP F7 NE SUPPLY FAN 0.190689
AIRLOOP F7 N1 SUPPLY FAN 0.137373
AIRLOOP F7 N2 SUPPLY FAN 0.136039
AIRLOOP F7 S1 SUPPLY FAN 0.185489
AIRLOOP F7 S2 SUPPLY FAN 0.186327
AIRLOOP F8 SW SUPPLY FAN 0.279858
AIRLOOP F8 NW SUPPLY FAN 0.253479
AIRLOOP F8 SE SUPPLY FAN 0.253274
AIRLOOP F8 NE SUPPLY FAN 0.190880
AIRLOOP F8 N1 SUPPLY FAN 0.138093
AIRLOOP F8 N2 SUPPLY FAN 0.136766
AIRLOOP F8 S1 SUPPLY FAN 0.185967
AIRLOOP F8 S2 SUPPLY FAN 0.186805
AIRLOOP F9 SW SUPPLY FAN 0.288623
AIRLOOP F9 NW SUPPLY FAN 0.262511
AIRLOOP F9 SE SUPPLY FAN 0.260045
AIRLOOP F9 NE SUPPLY FAN 0.194166
AIRLOOP F9 N1 SUPPLY FAN 0.145883
AIRLOOP F9 N2 SUPPLY FAN 0.144530
AIRLOOP F9 S1 SUPPLY FAN 0.191581
AIRLOOP F9 S2 SUPPLY FAN 0.192406
AIRLOOP T SW SUPPLY FAN 0.357686
AIRLOOP T NW SUPPLY FAN 0.318351
AIRLOOP T SE SUPPLY FAN 0.322787
AIRLOOP T NE SUPPLY FAN 0.242581
AIRLOOP T N1 SUPPLY FAN 0.186653
AIRLOOP T N2 SUPPLY FAN 0.186451
AIRLOOP T S1 SUPPLY FAN 0.264114
AIRLOOP T S2 SUPPLY FAN 0.264908


COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Heating Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP HEATING MODE AIRLOOP G SW 0.208526 3615.89 0.000079
HEAT PUMP HEATING MODE AIRLOOP G NW 0.187195 3274.33 0.000072
HEAT PUMP HEATING MODE AIRLOOP OFFICE 0.325790 5487.24 0.000120
HEAT PUMP HEATING MODE AIRLOOP G NE 0.156235 2865.06 0.000063
HEAT PUMP HEATING MODE AIRLOOP G N1 0.106987 2114.52 0.000046
HEAT PUMP HEATING MODE AIRLOOP G N2 0.106982 2123.52 0.000046
HEAT PUMP HEATING MODE AIRLOOP G S1 0.132893 2486.75 0.000054
HEAT PUMP HEATING MODE AIRLOOP G S2 0.139184 2576.07 0.000056
HEAT PUMP HEATING MODE AIRLOOP F2 SW 0.274797 4609.02 0.000101
HEAT PUMP HEATING MODE AIRLOOP F2 NW 0.247392 4198.77 0.000092
HEAT PUMP HEATING MODE AIRLOOP F2 SE 0.270610 4567.41 0.000100
HEAT PUMP HEATING MODE AIRLOOP F2 NE 0.187579 3291.40 0.000072
HEAT PUMP HEATING MODE AIRLOOP F2 N1 0.131032 2426.09 0.000053
HEAT PUMP HEATING MODE AIRLOOP F2 N2 0.129668 2406.11 0.000053
HEAT PUMP HEATING MODE AIRLOOP F2 S1 0.180117 3198.48 0.000070
HEAT PUMP HEATING MODE AIRLOOP F2 S2 0.182448 3231.48 0.000071
HEAT PUMP HEATING MODE AIRLOOP F3 SW 0.277518 4689.66 0.000102
HEAT PUMP HEATING MODE AIRLOOP F3 NW 0.250925 4289.48 0.000094
HEAT PUMP HEATING MODE AIRLOOP F3 SE 0.253027 4359.19 0.000095
HEAT PUMP HEATING MODE AIRLOOP F3 NE 0.191133 3387.18 0.000074
HEAT PUMP HEATING MODE AIRLOOP F3 N1 0.135403 2510.47 0.000055
HEAT PUMP HEATING MODE AIRLOOP F3 N2 0.134050 2490.59 0.000054
HEAT PUMP HEATING MODE AIRLOOP F3 S1 0.184298 3281.95 0.000072
HEAT PUMP HEATING MODE AIRLOOP F3 S2 0.185361 3296.98 0.000072
HEAT PUMP HEATING MODE AIRLOOP F4 SW 0.279105 4748.68 0.000104
HEAT PUMP HEATING MODE AIRLOOP F4 NW 0.252601 4343.30 0.000095
HEAT PUMP HEATING MODE AIRLOOP F4 SE 0.252608 4383.30 0.000096
HEAT PUMP HEATING MODE AIRLOOP F4 NE 0.192054 3427.72 0.000075
HEAT PUMP HEATING MODE AIRLOOP F4 N1 0.137112 2550.81 0.000056
HEAT PUMP HEATING MODE AIRLOOP F4 N2 0.135761 2530.89 0.000055
HEAT PUMP HEATING MODE AIRLOOP F4 S1 0.185778 3320.96 0.000073
HEAT PUMP HEATING MODE AIRLOOP F4 S2 0.186655 3333.37 0.000073
HEAT PUMP HEATING MODE AIRLOOP M SW 0.282299 4819.33 0.000105
HEAT PUMP HEATING MODE AIRLOOP M NW 0.255888 4414.47 0.000096
HEAT PUMP HEATING MODE AIRLOOP M SE 0.255585 4450.14 0.000097
HEAT PUMP HEATING MODE AIRLOOP M NE 0.194673 3487.52 0.000076
HEAT PUMP HEATING MODE AIRLOOP M N1 0.140259 2609.34 0.000057
HEAT PUMP HEATING MODE AIRLOOP M N2 0.138910 2589.43 0.000057
HEAT PUMP HEATING MODE AIRLOOP M S1 0.188767 3378.20 0.000074
HEAT PUMP HEATING MODE AIRLOOP M S2 0.189614 3390.20 0.000074
HEAT PUMP HEATING MODE AIRLOOP F6 SW 0.279770 4804.55 0.000105
HEAT PUMP HEATING MODE AIRLOOP F6 NW 0.253311 4397.84 0.000096
HEAT PUMP HEATING MODE AIRLOOP F6 SE 0.253102 4435.03 0.000097
HEAT PUMP HEATING MODE AIRLOOP F6 NE 0.191641 3461.88 0.000076
HEAT PUMP HEATING MODE AIRLOOP F6 N1 0.137843 2584.31 0.000056
HEAT PUMP HEATING MODE AIRLOOP F6 N2 0.136502 2564.43 0.000056
HEAT PUMP HEATING MODE AIRLOOP F6 S1 0.186143 3352.94 0.000073
HEAT PUMP HEATING MODE AIRLOOP F6 S2 0.186985 3364.87 0.000074
HEAT PUMP HEATING MODE AIRLOOP F7 SW 0.279239 4815.47 0.000105
HEAT PUMP HEATING MODE AIRLOOP F7 NW 0.252800 4408.15 0.000096
HEAT PUMP HEATING MODE AIRLOOP F7 SE 0.252628 4448.89 0.000097
HEAT PUMP HEATING MODE AIRLOOP F7 NE 0.190689 3463.85 0.000076
HEAT PUMP HEATING MODE AIRLOOP F7 N1 0.137373 2586.42 0.000056
HEAT PUMP HEATING MODE AIRLOOP F7 N2 0.136039 2566.57 0.000056
HEAT PUMP HEATING MODE AIRLOOP F7 S1 0.185489 3354.25 0.000073
HEAT PUMP HEATING MODE AIRLOOP F7 S2 0.186327 3366.15 0.000074
HEAT PUMP HEATING MODE AIRLOOP F8 SW 0.279858 4840.81 0.000106
HEAT PUMP HEATING MODE AIRLOOP F8 NW 0.253479 4433.65 0.000097
HEAT PUMP HEATING MODE AIRLOOP F8 SE 0.253274 4473.98 0.000098
HEAT PUMP HEATING MODE AIRLOOP F8 NE 0.190880 3480.66 0.000076
HEAT PUMP HEATING MODE AIRLOOP F8 N1 0.138093 2605.10 0.000057
HEAT PUMP HEATING MODE AIRLOOP F8 N2 0.136766 2585.31 0.000056
HEAT PUMP HEATING MODE AIRLOOP F8 S1 0.185967 3370.65 0.000074
HEAT PUMP HEATING MODE AIRLOOP F8 S2 0.186805 3382.56 0.000074
HEAT PUMP HEATING MODE AIRLOOP F9 SW 0.288623 4976.17 0.000109
HEAT PUMP HEATING MODE AIRLOOP F9 NW 0.262511 4578.53 0.000100
HEAT PUMP HEATING MODE AIRLOOP F9 SE 0.260045 4586.19 0.000100
HEAT PUMP HEATING MODE AIRLOOP F9 NE 0.194166 3550.26 0.000078
HEAT PUMP HEATING MODE AIRLOOP F9 N1 0.145883 2727.79 0.000060
HEAT PUMP HEATING MODE AIRLOOP F9 N2 0.144530 2707.68 0.000059
HEAT PUMP HEATING MODE AIRLOOP F9 S1 0.191581 3463.06 0.000076
HEAT PUMP HEATING MODE AIRLOOP F9 S2 0.192406 3474.79 0.000076
HEAT PUMP HEATING MODE AIRLOOP T SW 0.357686 5999.32 0.000131
HEAT PUMP HEATING MODE AIRLOOP T NW 0.318351 5415.59 0.000118
HEAT PUMP HEATING MODE AIRLOOP T SE 0.322787 5496.21 0.000120
HEAT PUMP HEATING MODE AIRLOOP T NE 0.242581 4353.25 0.000095
HEAT PUMP HEATING MODE AIRLOOP T N1 0.186653 3402.57 0.000074
HEAT PUMP HEATING MODE AIRLOOP T N2 0.186451 3399.99 0.000074
HEAT PUMP HEATING MODE AIRLOOP T S1 0.264114 4504.17 0.000098
HEAT PUMP HEATING MODE AIRLOOP T S2 0.264908 4515.29 0.000099


Coil:Heating:Electric

Nominal Capacity [W]
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW 4791.42
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW 4792.71
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE 5842.94
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE 4787.47
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 3709.69
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 3709.57
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 3705.85
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 3712.01
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW 4635.62
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW 4629.05
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE 4650.10
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE 4625.42
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 3290.66
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 3290.58
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 3300.33
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 3301.36
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW 4687.04
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW 4685.82
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE 4687.32
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE 4684.26
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 3270.88
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 3270.85
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 3273.27
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 3273.39
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW 4808.92
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW 4811.12
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE 4809.21
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE 4811.23
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 3334.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 3334.66
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 3333.33
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 3333.35
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW 4901.86
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW 4905.43
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE 4903.41
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE 4906.96
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 3379.84
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 3379.87
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 3377.05
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 3377.08
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW 5046.01
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW 5052.40
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE 5048.77
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE 5055.16
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 3482.67
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 3482.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 3477.05
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 3477.11
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW 5156.64
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW 5164.48
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE 5160.47
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE 5168.32
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 3557.01
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 3557.10
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 3549.93
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 3550.02
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW 5270.43
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW 5279.20
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE 5275.22
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE 5283.99
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 3638.12
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 3638.22
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 3630.10
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 3630.21
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW 5546.58
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW 5553.04
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE 5552.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE 5558.75
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 3870.79
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 3870.92
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 3864.63
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 3864.76
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW 6473.79
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW 6489.18
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE 6479.78
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE 6495.17
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 4848.84
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 4848.98
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 4830.67
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 4830.81


PlantLoop

Maximum Loop Flow Rate [m3/s] Plant Loop Volume [m3]
SHWSYS1 0.000289 0.325214
SINGLE WATER PLANT LOOP 0.006397 7.20


Boiler:HotWater

Design Water Flow Rate [m3/s]
CENTRAL BOILER 0.006397


WaterHeater:Mixed

Use Side Design Flow Rate [m3/s]
SHWSYS1 WATER HEATER 0.000289


EvaporativeFluidCooler:SingleSpeed

Design Water Flow Rate [m3/s] Fan Power at Design Air Flow Rate [W] Design Air Flow Rate [m3/s] U-Factor Times Area Value at Design Air Flow Rate [W/C]
CENTRAL TOWER 0.006397 3088.25 8.22 9469.02


Pump:ConstantSpeed

Rated Flow Rate [m3/s] Rated Power Consumption [W]
SHWSYS1 PUMP 0.000289 36.93
PLANT CIRC PUMP 0.006397 2042.95



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW3 |
G WWALL SWA GWINDOW2 |
G NWALL NWA GWINDOW4 |
G WWALL NWA GWINDOW6 |
G SWALL SEA GWINDOW1 |
G EWALL SEA GWINDOW8 |
G NWALL NEA GWINDOW5 |
G EWALL NEA GWINDOW7 |
G NWALL N1A GWINDOW9 |
G NWALL N2A GWINDOW10 |
G SWALL S1A GWINDOW11 |
G SWALL S2A GWINDOW12 |
G WWALL C GWINDOW13 |
G EWALL C ENTRANCE DOOR |
F2 WWALL SWA F2WINDOW2 |
F2 SWALL SWA F2WINDOW3 |
F2 NWALL NWA F2WINDOW4 |
F2 WWALL NWA F2WINDOW6 |
F2 EWALL SEA F2WINDOW8 |
F2 SWALL SEA F2WINDOW1 |
F2 NWALL NEA F2WINDOW5 |
F2 EWALL NEA F2WINDOW7 |
F2 NWALL N1A F2WINDOW9 |
F2 NWALL N2A F2WINDOW10 |
F2 SWALL S1A F2WINDOW11 |
F2 SWALL S2A F2WINDOW12 |
F2 WWALL C F2WINDOW13 |
F2 EWALL C F2WINDOW14 |
F3 WWALL SWA F3WINDOW2 |
F3 SWALL SWA F3WINDOW3 |
F3 NWALL NWA F3WINDOW4 |
F3 WWALL NWA F3WINDOW6 |
F3 EWALL SEA F3WINDOW8 |
F3 SWALL SEA F3WINDOW1 |
F3 NWALL NEA F3WINDOW5 |
F3 EWALL NEA F3WINDOW7 |
F3 NWALL N1A F3WINDOW9 |
F3 NWALL N2A F3WINDOW10 |
F3 SWALL S1A F3WINDOW11 |
F3 SWALL S2A F3WINDOW12 |
F3 WWALL C F3WINDOW13 |
F3 EWALL C F3WINDOW14 |
F4 WWALL SWA F4WINDOW2 |
F4 SWALL SWA F4WINDOW3 |
F4 NWALL NWA F4WINDOW4 |
F4 WWALL NWA F4WINDOW6 |
F4 EWALL SEA F4WINDOW8 |
F4 SWALL SEA F4WINDOW1 |
F4 NWALL NEA F4WINDOW5 |
F4 EWALL NEA F4WINDOW7 |
F4 NWALL N1A F4WINDOW9 |
F4 NWALL N2A F4WINDOW10 |
F4 SWALL S1A F4WINDOW11 |
F4 SWALL S2A F4WINDOW12 |
F4 WWALL C F4WINDOW13 |
F4 EWALL C F4WINDOW14 |
M WWALL SWA MWINDOW2 |
M SWALL SWA MWINDOW3 |
M NWALL NWA MWINDOW4 |
M WWALL NWA MWINDOW6 |
M EWALL SEA MWINDOW8 |
M SWALL SEA MWINDOW1 |
M NWALL NEA MWINDOW5 |
M EWALL NEA MWINDOW7 |
M NWALL N1A MWINDOW9 |
M NWALL N2A MWINDOW10 |
M SWALL S1A MWINDOW11 |
M SWALL S2A MWINDOW12 |
M WWALL C MWINDOW13 |
M EWALL C MWINDOW14 |
F6 WWALL SWA F6WINDOW2 |
F6 SWALL SWA F6WINDOW3 |
F6 NWALL NWA F6WINDOW4 |
F6 WWALL NWA F6WINDOW6 |
F6 EWALL SEA F6WINDOW8 |
F6 SWALL SEA F6WINDOW1 |
F6 NWALL NEA F6WINDOW5 |
F6 EWALL NEA F6WINDOW7 |
F6 NWALL N1A F6WINDOW9 |
F6 NWALL N2A F6WINDOW10 |
F6 SWALL S1A F6WINDOW11 |
F6 SWALL S2A F6WINDOW12 |
F6 WWALL C F6WINDOW13 |
F6 EWALL C F6WINDOW14 |
F7 WWALL SWA F7WINDOW2 |
F7 SWALL SWA F7WINDOW3 |
F7 NWALL NWA F7WINDOW4 |
F7 WWALL NWA F7WINDOW6 |
F7 EWALL SEA F7WINDOW8 |
F7 SWALL SEA F7WINDOW1 |
F7 NWALL NEA F7WINDOW5 |
F7 EWALL NEA F7WINDOW7 |
F7 NWALL N1A F7WINDOW9 |
F7 NWALL N2A F7WINDOW10 |
F7 SWALL S1A F7WINDOW11 |
F7 SWALL S2A F7WINDOW12 |
F7 WWALL C F7WINDOW13 |
F7 EWALL C F7WINDOW14 |
F8 WWALL SWA F8WINDOW2 |
F8 SWALL SWA F8WINDOW3 |
F8 NWALL NWA F8WINDOW4 |
F8 WWALL NWA F8WINDOW6 |
F8 EWALL SEA F8WINDOW8 |
F8 SWALL SEA F8WINDOW1 |
F8 NWALL NEA F8WINDOW5 |
F8 EWALL NEA F8WINDOW7 |
F8 NWALL N1A F8WINDOW9 |
F8 NWALL N2A F8WINDOW10 |
F8 SWALL S1A F8WINDOW11 |
F8 SWALL S2A F8WINDOW12 |
F8 WWALL C F8WINDOW13 |
F8 EWALL C F8WINDOW14 |
F9 WWALL SWA F9WINDOW2 |
F9 SWALL SWA F9WINDOW3 |
F9 NWALL NWA F9WINDOW4 |
F9 WWALL NWA F9WINDOW6 |
F9 EWALL SEA F9WINDOW8 |
F9 SWALL SEA F9WINDOW1 |
F9 NWALL NEA F9WINDOW5 |
F9 EWALL NEA F9WINDOW7 |
F9 NWALL N1A F9WINDOW9 |
F9 NWALL N2A F9WINDOW10 |
F9 SWALL S1A F9WINDOW11 |
F9 SWALL S2A F9WINDOW12 |
F9 WWALL C F9WINDOW13 |
F9 EWALL C F9WINDOW14 |
T WWALL SWA TWINDOW2 |
T SWALL SWA TWINDOW3 |
T NWALL NWA TWINDOW4 |
T WWALL NWA TWINDOW6 |
T EWALL SEA TWINDOW8 |
T SWALL SEA TWINDOW1 |
T NWALL NEA TWINDOW5 |
T EWALL NEA TWINDOW7 |
T NWALL N1A TWINDOW9 |
T NWALL N2A TWINDOW10 |
T SWALL S1A TWINDOW11 |
T SWALL S2A TWINDOW12 |
T WWALL C TWINDOW13 |
T EWALL C TWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.72 -5.6
March 21.92 -0.5
April 22.27 7.83
May 22.83 13.82
June 24.09 19.28
July 24.19 21.06
August 24.18 19.79
September 23.68 15.09
October 22.29 8.66
November 21.87 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.71 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.19 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.73 -0.5
April 22.04 7.83
May 22.58 13.82
June 24.07 19.28
July 24.18 21.06
August 24.09 19.79
September 23.38 15.09
October 21.86 8.66
November 21.71 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.57 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.18 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -7.2
February 21.79 -5.6
March 22.09 -0.5
April 22.67 7.83
May 23.48 13.82
June 24.34 19.28
July 24.37 21.06
August 24.35 19.79
September 23.90 15.09
October 22.75 8.66
November 22.10 2.78
December 21.79 -1.5
     
Annual Sum or Average 22.95 7.87
Minimum of Months 21.71 -7.2
Maximum of Months 24.37 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.71 -0.5
April 22.01 7.83
May 22.52 13.82
June 24.07 19.28
July 24.19 21.06
August 24.08 19.79
September 23.34 15.09
October 21.80 8.66
November 21.70 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.55 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.19 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.70 -0.5
April 21.93 7.83
May 22.34 13.82
June 23.96 19.28
July 24.11 21.06
August 23.99 19.79
September 23.35 15.09
October 21.83 8.66
November 21.70 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.50 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.11 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.70 -0.5
April 21.93 7.83
May 22.33 13.82
June 23.96 19.28
July 24.11 21.06
August 23.99 19.79
September 23.35 15.09
October 21.82 8.66
November 21.70 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.50 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.11 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.72 -5.6
March 21.90 -0.5
April 22.19 7.83
May 22.68 13.82
June 24.02 19.28
July 24.16 21.06
August 24.15 19.79
September 23.77 15.09
October 22.38 8.66
November 21.91 2.78
December 21.71 -1.5
     
Annual Sum or Average 22.70 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.16 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.73 -5.6
March 21.92 -0.5
April 22.23 7.83
May 22.76 13.82
June 24.05 19.28
July 24.17 21.06
August 24.17 19.79
September 23.81 15.09
October 22.43 8.66
November 21.93 2.78
December 21.71 -1.5
     
Annual Sum or Average 22.72 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.17 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 13.16 -7.2
February 13.65 -5.6
March 15.46 -0.5
April 18.51 7.83
May 20.87 13.82
June 23.80 19.28
July 24.57 21.06
August 24.09 19.79
September 22.11 15.09
October 18.72 8.66
November 16.33 2.78
December 14.77 -1.5
     
Annual Sum or Average 18.86 7.87
Minimum of Months 13.16 -7.2
Maximum of Months 24.57 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.76 -5.6
March 22.14 -0.5
April 22.74 7.83
May 23.75 13.82
June 24.30 19.28
July 24.32 21.06
August 24.32 19.79
September 23.91 15.09
October 22.83 8.66
November 22.03 2.78
December 21.71 -1.5
     
Annual Sum or Average 22.97 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.32 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.79 -0.5
April 22.32 7.83
May 23.41 13.82
June 24.30 19.28
July 24.31 21.06
August 24.24 19.79
September 23.59 15.09
October 22.05 8.66
November 21.72 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.74 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.31 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.76 -5.6
March 22.21 -0.5
April 22.90 7.83
May 23.93 13.82
June 24.34 19.28
July 24.35 21.06
August 24.35 19.79
September 23.99 15.09
October 22.99 8.66
November 22.09 2.78
December 21.72 -1.5
     
Annual Sum or Average 23.03 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.35 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.74 -0.5
April 22.27 7.83
May 23.30 13.82
June 24.30 19.28
July 24.33 21.06
August 24.24 19.79
September 23.52 15.09
October 21.93 8.66
November 21.71 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.71 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.33 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.74 -0.5
April 22.19 7.83
May 23.15 13.82
June 24.24 19.28
July 24.27 21.06
August 24.16 19.79
September 23.57 15.09
October 22.02 8.66
November 21.72 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.69 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.27 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.73 -0.5
April 22.19 7.83
May 23.14 13.82
June 24.24 19.28
July 24.28 21.06
August 24.16 19.79
September 23.57 15.09
October 22.01 8.66
November 21.72 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.68 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.28 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -7.2
February 21.79 -5.6
March 22.20 -0.5
April 22.77 7.83
May 23.68 13.82
June 24.25 19.28
July 24.29 21.06
August 24.30 19.79
September 24.03 15.09
October 23.09 8.66
November 22.16 2.78
December 21.74 -1.5
     
Annual Sum or Average 23.01 7.87
Minimum of Months 21.71 -7.2
Maximum of Months 24.30 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -7.2
February 21.79 -5.6
March 22.21 -0.5
April 22.79 7.83
May 23.72 13.82
June 24.26 19.28
July 24.29 21.06
August 24.31 19.79
September 24.04 15.09
October 23.12 8.66
November 22.17 2.78
December 21.74 -1.5
     
Annual Sum or Average 23.02 7.87
Minimum of Months 21.71 -7.2
Maximum of Months 24.31 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.51 -7.2
February 20.75 -5.6
March 21.60 -0.5
April 23.09 7.83
May 24.49 13.82
June 25.94 19.28
July 26.14 21.06
August 25.98 19.79
September 25.01 15.09
October 23.03 8.66
November 21.68 2.78
December 20.87 -1.5
     
Annual Sum or Average 23.27 7.87
Minimum of Months 20.51 -7.2
Maximum of Months 26.14 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.76 -5.6
March 22.18 -0.5
April 22.82 7.83
May 23.90 13.82
June 24.29 19.28
July 24.31 21.06
August 24.32 19.79
September 23.90 15.09
October 22.91 8.66
November 22.06 2.78
December 21.71 -1.5
     
Annual Sum or Average 23.00 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.32 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.80 -0.5
April 22.38 7.83
May 23.58 13.82
June 24.30 19.28
July 24.31 21.06
August 24.25 19.79
September 23.59 15.09
October 22.09 8.66
November 21.73 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.77 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.31 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.75 -5.6
March 22.18 -0.5
April 22.86 7.83
May 23.93 13.82
June 24.31 19.28
July 24.33 21.06
August 24.34 19.79
September 23.91 15.09
October 22.92 8.66
November 22.06 2.78
December 21.71 -1.5
     
Annual Sum or Average 23.01 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.34 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.75 -0.5
April 22.33 7.83
May 23.48 13.82
June 24.31 19.28
July 24.34 21.06
August 24.24 19.79
September 23.52 15.09
October 21.96 8.66
November 21.71 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.74 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.34 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.75 -0.5
April 22.30 7.83
May 23.39 13.82
June 24.26 19.28
July 24.29 21.06
August 24.18 19.79
September 23.60 15.09
October 22.09 8.66
November 21.73 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.73 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.29 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.75 -0.5
April 22.29 7.83
May 23.38 13.82
June 24.26 19.28
July 24.29 21.06
August 24.18 19.79
September 23.59 15.09
October 22.08 8.66
November 21.73 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.73 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.29 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -7.2
February 21.80 -5.6
March 22.27 -0.5
April 22.93 7.83
May 23.91 13.82
June 24.26 19.28
July 24.29 21.06
August 24.31 19.79
September 24.04 15.09
October 23.27 8.66
November 22.21 2.78
December 21.74 -1.5
     
Annual Sum or Average 23.07 7.87
Minimum of Months 21.71 -7.2
Maximum of Months 24.31 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -7.2
February 21.80 -5.6
March 22.27 -0.5
April 22.94 7.83
May 23.92 13.82
June 24.26 19.28
July 24.29 21.06
August 24.31 19.79
September 24.04 15.09
October 23.28 8.66
November 22.22 2.78
December 21.74 -1.5
     
Annual Sum or Average 23.07 7.87
Minimum of Months 21.71 -7.2
Maximum of Months 24.31 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.10 -7.2
February 21.32 -5.6
March 22.15 -0.5
April 23.58 7.83
May 25.01 13.82
June 26.15 19.28
July 26.30 21.06
August 26.16 19.79
September 25.24 15.09
October 23.46 8.66
November 22.13 2.78
December 21.35 -1.5
     
Annual Sum or Average 23.67 7.87
Minimum of Months 21.10 -7.2
Maximum of Months 26.30 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.76 -5.6
March 22.17 -0.5
April 22.80 7.83
May 23.91 13.82
June 24.28 19.28
July 24.31 21.06
August 24.33 19.79
September 23.89 15.09
October 22.92 8.66
November 22.05 2.78
December 21.71 -1.5
     
Annual Sum or Average 22.99 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.33 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.80 -0.5
April 22.38 7.83
May 23.60 13.82
June 24.30 19.28
July 24.31 21.06
August 24.26 19.79
September 23.59 15.09
October 22.10 8.66
November 21.72 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.77 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.31 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.74 -5.6
March 22.16 -0.5
April 22.82 7.83
May 23.91 13.82
June 24.30 19.28
July 24.33 21.06
August 24.34 19.79
September 23.89 15.09
October 22.88 8.66
November 22.04 2.78
December 21.71 -1.5
     
Annual Sum or Average 22.99 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.34 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.75 -0.5
April 22.34 7.83
May 23.51 13.82
June 24.30 19.28
July 24.34 21.06
August 24.25 19.79
September 23.53 15.09
October 21.97 8.66
November 21.71 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.74 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.34 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.76 -0.5
April 22.32 7.83
May 23.46 13.82
June 24.26 19.28
July 24.29 21.06
August 24.20 19.79
September 23.62 15.09
October 22.12 8.66
November 21.73 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.74 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.29 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.75 -0.5
April 22.32 7.83
May 23.45 13.82
June 24.26 19.28
July 24.29 21.06
August 24.20 19.79
September 23.62 15.09
October 22.11 8.66
November 21.73 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.74 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.29 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -7.2
February 21.79 -5.6
March 22.27 -0.5
April 22.95 7.83
May 23.95 13.82
June 24.25 19.28
July 24.29 21.06
August 24.32 19.79
September 24.04 15.09
October 23.32 8.66
November 22.21 2.78
December 21.74 -1.5
     
Annual Sum or Average 23.08 7.87
Minimum of Months 21.71 -7.2
Maximum of Months 24.32 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -7.2
February 21.79 -5.6
March 22.27 -0.5
April 22.96 7.83
May 23.95 13.82
June 24.25 19.28
July 24.29 21.06
August 24.32 19.79
September 24.04 15.09
October 23.32 8.66
November 22.22 2.78
December 21.74 -1.5
     
Annual Sum or Average 23.08 7.87
Minimum of Months 21.71 -7.2
Maximum of Months 24.32 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.23 -7.2
February 21.45 -5.6
March 22.28 -0.5
April 23.71 7.83
May 25.18 13.82
June 26.24 19.28
July 26.38 21.06
August 26.25 19.79
September 25.33 15.09
October 23.59 8.66
November 22.26 2.78
December 21.47 -1.5
     
Annual Sum or Average 23.79 7.87
Minimum of Months 21.23 -7.2
Maximum of Months 26.38 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.75 -5.6
March 22.16 -0.5
April 22.77 7.83
May 23.89 13.82
June 24.27 19.28
July 24.30 21.06
August 24.32 19.79
September 23.87 15.09
October 22.88 8.66
November 22.03 2.78
December 21.71 -1.5
     
Annual Sum or Average 22.98 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.32 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.80 -0.5
April 22.37 7.83
May 23.58 13.82
June 24.29 19.28
July 24.30 21.06
August 24.25 19.79
September 23.57 15.09
October 22.09 8.66
November 21.72 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.76 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.30 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.74 -5.6
March 22.15 -0.5
April 22.78 7.83
May 23.88 13.82
June 24.29 19.28
July 24.32 21.06
August 24.33 19.79
September 23.86 15.09
October 22.83 8.66
November 22.03 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.97 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.33 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.75 -0.5
April 22.32 7.83
May 23.49 13.82
June 24.29 19.28
July 24.33 21.06
August 24.24 19.79
September 23.52 15.09
October 21.97 8.66
November 21.71 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.73 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.33 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.76 -0.5
April 22.33 7.83
May 23.47 13.82
June 24.25 19.28
July 24.29 21.06
August 24.20 19.79
September 23.62 15.09
October 22.13 8.66
November 21.73 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.74 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.29 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.76 -0.5
April 22.32 7.83
May 23.46 13.82
June 24.25 19.28
July 24.29 21.06
August 24.20 19.79
September 23.61 15.09
October 22.12 8.66
November 21.73 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.74 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.29 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -7.2
February 21.79 -5.6
March 22.27 -0.5
April 22.93 7.83
May 23.94 13.82
June 24.24 19.28
July 24.28 21.06
August 24.31 19.79
September 24.02 15.09
October 23.30 8.66
November 22.21 2.78
December 21.73 -1.5
     
Annual Sum or Average 23.07 7.87
Minimum of Months 21.71 -7.2
Maximum of Months 24.31 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -7.2
February 21.79 -5.6
March 22.27 -0.5
April 22.94 7.83
May 23.94 13.82
June 24.24 19.28
July 24.28 21.06
August 24.32 19.79
September 24.02 15.09
October 23.30 8.66
November 22.21 2.78
December 21.73 -1.5
     
Annual Sum or Average 23.07 7.87
Minimum of Months 21.71 -7.2
Maximum of Months 24.32 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.78 -7.2
February 21.99 -5.6
March 22.83 -0.5
April 24.25 7.83
May 25.72 13.82
June 26.77 19.28
July 26.91 21.06
August 26.78 19.79
September 25.86 15.09
October 24.14 8.66
November 22.83 2.78
December 22.04 -1.5
     
Annual Sum or Average 24.34 7.87
Minimum of Months 21.78 -7.2
Maximum of Months 26.91 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.75 -5.6
March 22.12 -0.5
April 22.68 7.83
May 23.78 13.82
June 24.25 19.28
July 24.29 21.06
August 24.31 19.79
September 23.80 15.09
October 22.76 8.66
November 22.00 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.93 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.31 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.78 -0.5
April 22.31 7.83
May 23.46 13.82
June 24.27 19.28
July 24.29 21.06
August 24.22 19.79
September 23.50 15.09
October 22.03 8.66
November 21.72 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.73 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.29 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.73 -5.6
March 22.11 -0.5
April 22.69 7.83
May 23.77 13.82
June 24.26 19.28
July 24.30 21.06
August 24.32 19.79
September 23.79 15.09
October 22.71 8.66
November 21.99 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.93 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.32 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.74 -0.5
April 22.26 7.83
May 23.36 13.82
June 24.27 19.28
July 24.32 21.06
August 24.21 19.79
September 23.44 15.09
October 21.91 8.66
November 21.71 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.70 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.32 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.75 -0.5
April 22.26 7.83
May 23.35 13.82
June 24.22 19.28
July 24.27 21.06
August 24.16 19.79
September 23.54 15.09
October 22.06 8.66
November 21.72 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.71 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.27 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.74 -0.5
April 22.26 7.83
May 23.34 13.82
June 24.22 19.28
July 24.27 21.06
August 24.16 19.79
September 23.54 15.09
October 22.05 8.66
November 21.72 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.71 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.27 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -7.2
February 21.78 -5.6
March 22.23 -0.5
April 22.83 7.83
May 23.84 13.82
June 24.21 19.28
July 24.26 21.06
August 24.29 19.79
September 23.95 15.09
October 23.17 8.66
November 22.16 2.78
December 21.72 -1.5
     
Annual Sum or Average 23.02 7.87
Minimum of Months 21.71 -7.2
Maximum of Months 24.29 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -7.2
February 21.78 -5.6
March 22.23 -0.5
April 22.84 7.83
May 23.84 13.82
June 24.21 19.28
July 24.26 21.06
August 24.29 19.79
September 23.95 15.09
October 23.17 8.66
November 22.16 2.78
December 21.72 -1.5
     
Annual Sum or Average 23.02 7.87
Minimum of Months 21.71 -7.2
Maximum of Months 24.29 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.16 -7.2
February 21.37 -5.6
March 22.20 -0.5
April 23.60 7.83
May 25.06 13.82
June 26.19 19.28
July 26.34 21.06
August 26.20 19.79
September 25.23 15.09
October 23.47 8.66
November 22.19 2.78
December 21.40 -1.5
     
Annual Sum or Average 23.71 7.87
Minimum of Months 21.16 -7.2
Maximum of Months 26.34 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.74 -5.6
March 22.09 -0.5
April 22.61 7.83
May 23.69 13.82
June 24.23 19.28
July 24.27 21.06
August 24.29 19.79
September 23.75 15.09
October 22.66 8.66
November 21.97 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.90 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.29 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.77 -0.5
April 22.27 7.83
May 23.37 13.82
June 24.25 19.28
July 24.27 21.06
August 24.20 19.79
September 23.44 15.09
October 21.98 8.66
November 21.71 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.70 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.27 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.73 -5.6
March 22.08 -0.5
April 22.62 7.83
May 23.68 13.82
June 24.24 19.28
July 24.29 21.06
August 24.30 19.79
September 23.74 15.09
October 22.61 8.66
November 21.97 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.89 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.30 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.74 -0.5
April 22.23 7.83
May 23.26 13.82
June 24.24 19.28
July 24.30 21.06
August 24.19 19.79
September 23.38 15.09
October 21.88 8.66
November 21.70 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.67 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.30 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.74 -0.5
April 22.22 7.83
May 23.25 13.82
June 24.20 19.28
July 24.25 21.06
August 24.13 19.79
September 23.48 15.09
October 22.01 8.66
November 21.72 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.68 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.25 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.74 -0.5
April 22.21 7.83
May 23.24 13.82
June 24.20 19.28
July 24.25 21.06
August 24.13 19.79
September 23.48 15.09
October 22.00 8.66
November 21.72 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.68 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.25 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.77 -5.6
March 22.20 -0.5
April 22.75 7.83
May 23.75 13.82
June 24.19 19.28
July 24.25 21.06
August 24.28 19.79
September 23.89 15.09
October 23.06 8.66
November 22.13 2.78
December 21.72 -1.5
     
Annual Sum or Average 22.98 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.28 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.77 -5.6
March 22.19 -0.5
April 22.76 7.83
May 23.75 13.82
June 24.19 19.28
July 24.25 21.06
August 24.28 19.79
September 23.90 15.09
October 23.05 8.66
November 22.13 2.78
December 21.72 -1.5
     
Annual Sum or Average 22.98 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.28 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.02 -7.2
February 21.22 -5.6
March 22.05 -0.5
April 23.43 7.83
May 24.88 13.82
June 26.08 19.28
July 26.25 21.06
August 26.10 19.79
September 25.08 15.09
October 23.29 8.66
November 22.04 2.78
December 21.26 -1.5
     
Annual Sum or Average 23.57 7.87
Minimum of Months 21.02 -7.2
Maximum of Months 26.25 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.74 -5.6
March 22.07 -0.5
April 22.56 7.83
May 23.62 13.82
June 24.21 19.28
July 24.26 21.06
August 24.28 19.79
September 23.70 15.09
October 22.58 8.66
November 21.95 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.87 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.28 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.77 -0.5
April 22.24 7.83
May 23.29 13.82
June 24.23 19.28
July 24.26 21.06
August 24.18 19.79
September 23.39 15.09
October 21.95 8.66
November 21.71 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.68 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.26 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.73 -5.6
March 22.05 -0.5
April 22.57 7.83
May 23.60 13.82
June 24.22 19.28
July 24.28 21.06
August 24.29 19.79
September 23.69 15.09
October 22.52 8.66
November 21.94 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.86 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.29 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.73 -0.5
April 22.20 7.83
May 23.17 13.82
June 24.23 19.28
July 24.29 21.06
August 24.16 19.79
September 23.33 15.09
October 21.85 8.66
November 21.70 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.65 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.29 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.73 -0.5
April 22.18 7.83
May 23.17 13.82
June 24.18 19.28
July 24.24 21.06
August 24.11 19.79
September 23.43 15.09
October 21.98 8.66
November 21.71 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.66 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.24 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.73 -0.5
April 22.18 7.83
May 23.16 13.82
June 24.18 19.28
July 24.24 21.06
August 24.11 19.79
September 23.43 15.09
October 21.97 8.66
November 21.71 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.66 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.24 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.76 -5.6
March 22.17 -0.5
April 22.68 7.83
May 23.67 13.82
June 24.17 19.28
July 24.24 21.06
August 24.26 19.79
September 23.84 15.09
October 22.95 8.66
November 22.10 2.78
December 21.72 -1.5
     
Annual Sum or Average 22.95 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.26 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.76 -5.6
March 22.17 -0.5
April 22.69 7.83
May 23.67 13.82
June 24.17 19.28
July 24.24 21.06
August 24.26 19.79
September 23.85 15.09
October 22.95 8.66
November 22.10 2.78
December 21.72 -1.5
     
Annual Sum or Average 22.95 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.26 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.93 -7.2
February 21.13 -5.6
March 21.96 -0.5
April 23.33 7.83
May 24.77 13.82
June 26.05 19.28
July 26.23 21.06
August 26.07 19.79
September 24.99 15.09
October 23.17 8.66
November 21.95 2.78
December 21.18 -1.5
     
Annual Sum or Average 23.49 7.87
Minimum of Months 20.93 -7.2
Maximum of Months 26.23 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.74 -5.6
March 22.04 -0.5
April 22.51 7.83
May 23.53 13.82
June 24.19 19.28
July 24.25 21.06
August 24.26 19.79
September 23.64 15.09
October 22.48 8.66
November 21.92 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.84 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.26 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.76 -0.5
April 22.22 7.83
May 23.22 13.82
June 24.21 19.28
July 24.25 21.06
August 24.15 19.79
September 23.34 15.09
October 21.92 8.66
November 21.71 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.66 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.25 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.73 -5.6
March 22.02 -0.5
April 22.52 7.83
May 23.51 13.82
June 24.20 19.28
July 24.26 21.06
August 24.27 19.79
September 23.63 15.09
October 22.42 8.66
November 21.91 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.83 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.27 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.73 -0.5
April 22.18 7.83
May 23.10 13.82
June 24.20 19.28
July 24.28 21.06
August 24.14 19.79
September 23.27 15.09
October 21.83 8.66
November 21.70 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.63 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.28 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.73 -0.5
April 22.16 7.83
May 23.11 13.82
June 24.17 19.28
July 24.22 21.06
August 24.09 19.79
September 23.37 15.09
October 21.95 8.66
November 21.71 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.64 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.22 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.73 -0.5
April 22.16 7.83
May 23.10 13.82
June 24.17 19.28
July 24.23 21.06
August 24.09 19.79
September 23.36 15.09
October 21.94 8.66
November 21.71 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.64 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.23 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.75 -5.6
March 22.13 -0.5
April 22.61 7.83
May 23.59 13.82
June 24.16 19.28
July 24.22 21.06
August 24.25 19.79
September 23.78 15.09
October 22.81 8.66
November 22.05 2.78
December 21.71 -1.5
     
Annual Sum or Average 22.90 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.25 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.75 -5.6
March 22.13 -0.5
April 22.61 7.83
May 23.59 13.82
June 24.16 19.28
July 24.22 21.06
August 24.25 19.79
September 23.78 15.09
October 22.81 8.66
November 22.05 2.78
December 21.71 -1.5
     
Annual Sum or Average 22.90 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.25 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.72 -7.2
February 20.93 -5.6
March 21.79 -0.5
April 23.22 7.83
May 24.69 13.82
June 26.06 19.28
July 26.26 21.06
August 26.08 19.79
September 24.91 15.09
October 23.02 8.66
November 21.78 2.78
December 21.00 -1.5
     
Annual Sum or Average 23.39 7.87
Minimum of Months 20.72 -7.2
Maximum of Months 26.26 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.75 -5.6
March 22.02 -0.5
April 22.46 7.83
May 23.29 13.82
June 24.06 19.28
July 24.15 21.06
August 24.14 19.79
September 23.48 15.09
October 22.38 8.66
November 21.91 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.76 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.15 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.80 -0.5
April 22.22 7.83
May 23.06 13.82
June 24.07 19.28
July 24.15 21.06
August 24.04 19.79
September 23.20 15.09
October 21.95 8.66
November 21.71 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.61 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.15 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.74 -5.6
March 22.01 -0.5
April 22.46 7.83
May 23.27 13.82
June 24.07 19.28
July 24.17 21.06
August 24.16 19.79
September 23.46 15.09
October 22.34 8.66
November 21.90 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.75 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.17 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.76 -0.5
April 22.18 7.83
May 22.97 13.82
June 24.05 19.28
July 24.16 21.06
August 24.02 19.79
September 23.12 15.09
October 21.85 8.66
November 21.70 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.58 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.16 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.75 -0.5
April 22.15 7.83
May 22.97 13.82
June 24.05 19.28
July 24.13 21.06
August 23.98 19.79
September 23.21 15.09
October 21.93 8.66
November 21.71 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.59 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.13 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.75 -0.5
April 22.15 7.83
May 22.97 13.82
June 24.05 19.28
July 24.13 21.06
August 23.98 19.79
September 23.20 15.09
October 21.92 8.66
November 21.71 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.58 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.13 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -7.2
February 21.77 -5.6
March 22.08 -0.5
April 22.53 7.83
May 23.40 13.82
June 24.06 19.28
July 24.14 21.06
August 24.16 19.79
September 23.61 15.09
October 22.59 8.66
November 22.00 2.78
December 21.72 -1.5
     
Annual Sum or Average 22.82 7.87
Minimum of Months 21.71 -7.2
Maximum of Months 24.16 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 -7.2
February 21.77 -5.6
March 22.08 -0.5
April 22.53 7.83
May 23.40 13.82
June 24.06 19.28
July 24.15 21.06
August 24.16 19.79
September 23.62 15.09
October 22.59 8.66
November 22.00 2.78
December 21.72 -1.5
     
Annual Sum or Average 22.82 7.87
Minimum of Months 21.71 -7.2
Maximum of Months 24.16 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.36 -7.2
February 20.68 -5.6
March 21.73 -0.5
April 23.46 7.83
May 25.10 13.82
June 26.71 19.28
July 26.96 21.06
August 26.71 19.79
September 25.27 15.09
October 23.16 8.66
November 21.72 2.78
December 20.81 -1.5
     
Annual Sum or Average 23.57 7.87
Minimum of Months 20.36 -7.2
Maximum of Months 26.96 21.06



Table of Contents

Report: COMPONENTS OF PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2015-09-09 19:00:30

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY {AT MAX/MIN} [W] HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W]
January 0.299647E+12 175367.334 23-JAN-21:00 11839.540 45992.891 19201.552 84361.088 0.000 10364.000 2079.877 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
February 0.262556E+12 189762.541 07-FEB-17:00 11327.174 57142.088 19201.552 87652.691 0.000 10364.000 2079.877 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
March 0.255630E+12 164244.593 07-MAR-13:00 9104.941 34496.599 19201.552 98262.384 0.000 0.000 2079.877 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
April 0.211668E+12 147413.915 21-APR-17:15 13120.457 57042.023 19201.552 0.000 52023.763 0.000 2079.877 1958.432 0.000 0.000 0.000 0.000 0.000 0.000 0.000
May 0.202342E+12 150261.171 31-MAY-17:30 13120.457 57042.023 19201.552 0.000 54780.580 0.000 2079.877 2048.673 0.000 0.000 0.000 0.000 0.000 0.000 0.000
June 0.236961E+12 171885.493 16-JUN-19:45 14401.373 49889.926 19201.552 0.000 71497.415 10364.000 2079.877 2810.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000
July 0.269929E+12 174798.235 20-JUL-19:30 14401.373 49889.926 19201.552 0.000 74131.956 10364.000 2079.877 3088.247 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 0.261242E+12 171984.683 04-AUG-17:15 13120.457 57042.023 19201.552 0.000 75519.016 0.000 2079.877 3033.946 0.000 0.000 0.000 0.000 0.000 0.000 0.000
September 0.218181E+12 153170.629 04-SEP-16:15 11327.174 57042.023 19201.552 0.000 59239.753 0.000 2079.877 2292.608 0.000 0.000 0.000 0.000 0.000 0.000 0.000
October 0.210785E+12 120473.186 06-OCT-17:30 13120.457 57042.023 19201.552 16677.268 0.000 10364.000 2079.877 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
November 0.238332E+12 141526.437 29-NOV-17:15 11327.174 57142.088 19201.552 39416.550 0.000 10364.000 2079.877 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
December 0.277974E+12 171502.437 17-DEC-17:00 11327.174 57042.023 19201.552 69499.999 0.000 10364.000 2079.877 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
                                     
Annual Sum or Average 0.294525E+13                     0.000 0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.202342E+12 120473.186   9104.941 34496.599 19201.552 0.000 0.000 0.000 2079.877 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.299647E+12 189762.541   14401.373 57142.088 19201.552 98262.384 75519.016 10364.000 2079.877 3088.247 0.000 0.000 0.000 0.000 0.000 0.000 0.000



Table of Contents

Report: COMPONENTS OF PEAK GAS DEMAND

For: Meter

Timestamp: 2015-09-09 19:00:30

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC [Invalid/Undefined] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT {AT MAX/MIN} [W] WATERSYSTEMS:GAS {AT MAX/MIN} [W] WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] HEATING:GAS {AT MAX/MIN} [W]
January 0.526105E+12 372607.720 24-JAN-07:30 0.000 0.000 0.000 372607.720 84624.482 84624.482 287983.237
February 0.443849E+12 360430.053 22-FEB-08:45 0.000 0.000 0.000 360430.053 83565.156 83565.156 276864.896
March 0.343465E+12 366275.098 07-MAR-07:30 0.000 0.000 0.000 366275.098 82672.134 82672.134 283602.964
April 0.174643E+12 269396.118 09-APR-05:15 0.000 0.000 0.000 269396.118 68807.741 68807.741 200588.377
May 0.108502E+12 105159.686 08-MAY-07:15 0.000 0.000 0.000 105159.686 80670.615 80670.615 24489.070
June 0.968108E+11 79442.548 01-JUN-06:00 0.000 0.000 0.000 79442.548 79442.548 79442.548 0.000
July 0.951746E+11 77329.825 01-JUL-06:45 0.000 0.000 0.000 77329.825 77329.825 77329.825 0.000
August 0.930332E+11 76071.875 03-AUG-06:00 0.000 0.000 0.000 76071.875 76071.875 76071.875 0.000
September 0.951095E+11 121028.134 30-SEP-07:30 0.000 0.000 0.000 121028.134 75775.498 75775.498 45252.636
October 0.134225E+12 165756.512 31-OCT-06:45 0.000 0.000 0.000 165756.512 78865.142 78865.142 86891.370
November 0.269234E+12 263622.334 29-NOV-08:15 0.000 0.000 0.000 263622.334 80415.379 80415.379 183206.955
December 0.419772E+12 368998.485 17-DEC-07:30 0.000 0.000 0.000 368998.485 82448.686 82448.686 286549.799
                     
Annual Sum or Average 0.279992E+13     0.000 0.000 0.000        
Minimum of Months 0.930332E+11 76071.875   0.000 0.000 0.000 76071.875 68807.741 68807.741 0.000
Maximum of Months 0.526105E+12 372607.720   0.000 0.000 0.000 372607.720 84624.482 84624.482 287983.237