Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 19:11

Tabular Output Report in Format: HTML

Building: High-Rise Apartment

Environment: San Francisco Intl Ap CA USA TMY3 WMO#=724940

Simulation Timestamp: 2015-09-09 19:12:07


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:07

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 3475.58 443.51 492.30
Net Site Energy 3475.58 443.51 492.30
Total Source Energy 8448.61 1078.11 1196.70
Net Source Energy 8448.61 1078.11 1196.70


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 7836.48
Net Conditioned Building Area 7059.89
Unconditioned Building Area 776.58


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 55.40 134.51 0.00 0.00 0.00 0.00
Cooling 45.38 0.00 0.00 0.00 0.00 0.00
Interior Lighting 296.56 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 162.73 0.00 0.00 0.00 0.00 0.00
Interior Equipment 1137.32 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 473.52 0.00 0.00 0.00 0.00 0.00
Pumps 38.45 0.00 0.00 0.00 0.00 0.00
Heat Rejection 1.75 0.00 0.00 0.00 0.00 179.99
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 1093.79 0.00 0.00 0.00 4778.51
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 2247.28 1228.31 0.00 0.00 0.00 4958.51
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating Boiler 0.00 134.51 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
  Other 55.40 0.00 0.00 0.00 0.00 0.00
Cooling General 45.38 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 242.55 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 54.01 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 162.73 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 1137.32 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 473.52 0.00 0.00 0.00 0.00 0.00
Pumps General 38.45 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 1.75 0.00 0.00 0.00 0.00 179.99
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 1093.79 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 4778.51
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 65.06 0.00 0.00 0.00 0.00 0.00
HVAC 87.04 173.98 0.00 0.00 0.00 0.70
Other 161.10 0.00 0.00 0.00 0.00 0.00
Total 318.32 173.98 0.00 0.00 0.00 0.70


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 58.61 0.00 0.00 0.00 0.00 0.00
HVAC 78.41 156.74 0.00 0.00 0.00 0.63
Other 145.13 0.00 0.00 0.00 0.00 0.00
Total 286.77 156.74 0.00 0.00 0.00 0.63


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 2247.28 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 2247.28 100.00
     
Total On-Site and Utility Electric Sources 2247.28 100.00
Total Electricity End Uses 2247.28 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 4958.51 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 4958.51 100.00
Total Water End Uses 4958.51 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 119.00
Time Setpoint Not Met During Occupied Cooling 12.75
Time Not Comfortable Based on Simple ASHRAE 55-2004 72.75


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |

COMPONENTS OF PEAK ELECTRICAL DEMAND

| Meter |

COMPONENTS OF PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:07

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 19:11
RunPeriod San Francisco Intl Ap CA USA TMY3 WMO#=724940
Weather File San Francisco Intl Ap CA USA TMY3 WMO#=724940
Latitude [deg] 37.62
Longitude [deg] -122.4
Elevation [m] 2.00
Time Zone -8.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3855.02 1411.96 515.55 1411.96 515.55
Window Opening Area [m2] 1150.39 423.59 152.73 423.59 150.48
Window-Wall Ratio [%] 29.84 30.00 29.62 30.00 29.19


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3752.84 1411.96 464.46 1411.96 464.46
Window Opening Area [m2] 1125.85 423.59 139.34 423.59 139.34
Window-Wall Ratio [%] 30.00 30.00 30.00 30.00 30.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
OFFICE 88.25 Yes Yes 268.96 1.00 58.52 17.56 29.5362 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 4.47 6.7128   0.0000
F2 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F3 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F4 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
M SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
M CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 13.4255   0.0000
F6 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F7 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F8 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F9 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
T SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   264.3872
Total 7836.48     23884.04   3855.02 1150.39 4.3335 39.48 8.6291
Conditioned Total 7059.89     21517.16   3752.84 1125.85 3.9979 35.57 6.6700
Unconditioned Total 776.58     2366.87   102.18 24.54 7.3840   26.4387
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:07

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 30-JUN-16:45 17-MAY-19:00 - - - 30-JUN-17:15
Heating 0.00 118213.39 0.00 0.00 0.00 0.00
Cooling 47332.16 0.00 0.00 0.00 0.00 0.00
Interior Lighting 11327.17 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 57142.09 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 15015.24 0.00 0.00 0.00 0.00 0.00
Pumps 1332.31 0.00 0.00 0.00 0.00 0.00
Heat Rejection 1520.03 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 68877.58 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 135664.16 187090.97 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating Boiler 0.00 118213.39 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 47332.16 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 9220.52 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 2106.65 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 57142.09 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 15015.24 0.00 0.00 0.00 0.00 0.00
Pumps General 1332.31 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 1520.03 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 68877.58 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:07

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 175.45 145.81 0.00 0.00 0.00
Cooling 143.70 0.00 0.00 0.00 0.00
Interior Lighting 939.20 0.00 0.00 0.00 0.00
Exterior Lighting 515.36 0.00 0.00 0.00 0.00
Interior Equipment 3601.91 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 1499.64 0.00 0.00 0.00 0.00
Pumps 121.76 0.00 0.00 0.00 0.00
Heat Rejection 5.53 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 1185.67 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 7117.12 1331.49 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 24.85 20.65 0.00 0.00 0.00
Cooling 20.35 0.00 0.00 0.00 0.00
Interior Lighting 133.03 0.00 0.00 0.00 0.00
Exterior Lighting 73.00 0.00 0.00 0.00 0.00
Interior Equipment 510.19 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 212.42 0.00 0.00 0.00 0.00
Pumps 17.25 0.00 0.00 0.00 0.00
Heat Rejection 0.78 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 167.94 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1008.11 188.60 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 24.85 20.65 0.00 0.00 0.00
Cooling 20.35 0.00 0.00 0.00 0.00
Interior Lighting 133.03 0.00 0.00 0.00 0.00
Exterior Lighting 73.00 0.00 0.00 0.00 0.00
Interior Equipment 510.19 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 212.42 0.00 0.00 0.00 0.00
Pumps 17.25 0.00 0.00 0.00 0.00
Heat Rejection 0.78 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 167.94 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1008.11 188.60 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:07

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 3.80 0.00 3.80 Wetbulb [C] 2.20 150.00
SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 28.30 8.50 17.20 Wetbulb [C] 5.90 310.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:07

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 270.00 180.00  
F2 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F2 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F2 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F2 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F2 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F2 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F3 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F3 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F3 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F3 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F3 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F3 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F4 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F4 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F4 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F4 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F4 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F4 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
M WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F6 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F6 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F6 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F6 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F6 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F6 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F7 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F7 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F7 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F7 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F7 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F7 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F8 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F8 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F8 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F8 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F8 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F8 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F9 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F9 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F9 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F9 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F9 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F9 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.30 0.269 0.283 77.66 0.00 0.00  


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW3 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No G SWALL SWA 180.00 90.00 S
GWINDOW2 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No G WWALL SWA 270.00 90.00 W
GWINDOW4 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No G NWALL NWA 0.00 90.00 N
GWINDOW6 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No G WWALL NWA 270.00 90.00 W
GWINDOW1 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No G SWALL SEA 180.00 90.00 S
GWINDOW8 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No G EWALL SEA 90.00 90.00 E
GWINDOW5 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No G NWALL NEA 0.00 90.00 N
GWINDOW7 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No G EWALL NEA 90.00 90.00 E
GWINDOW9 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No G NWALL N1A 0.00 90.00 N
GWINDOW10 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No G NWALL N2A 0.00 90.00 N
GWINDOW11 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No G SWALL S1A 180.00 90.00 S
GWINDOW12 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No G SWALL S2A 180.00 90.00 S
GWINDOW13 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No G WWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.65_SHGC_0.25 3.36 0.00 0.00 3.36 3.36 2.848 0.287 0.200     No G EWALL C 90.00 90.00 E
F2WINDOW2 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F2 WWALL SWA 270.00 90.00 W
F2WINDOW3 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F2 SWALL SWA 180.00 90.00 S
F2WINDOW4 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F2 NWALL NWA 0.00 90.00 N
F2WINDOW6 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F2 WWALL NWA 270.00 90.00 W
F2WINDOW8 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F2 EWALL SEA 90.00 90.00 E
F2WINDOW1 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F2 SWALL SEA 180.00 90.00 S
F2WINDOW5 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F2 NWALL NEA 0.00 90.00 N
F2WINDOW7 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F2 EWALL NEA 90.00 90.00 E
F2WINDOW9 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F2 NWALL N1A 0.00 90.00 N
F2WINDOW10 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F2 NWALL N2A 0.00 90.00 N
F2WINDOW11 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F2 SWALL S1A 180.00 90.00 S
F2WINDOW12 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F2 SWALL S2A 180.00 90.00 S
F2WINDOW13 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F2 WWALL C 270.00 90.00 W
F2WINDOW14 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F2 EWALL C 90.00 90.00 E
F3WINDOW2 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F3 WWALL SWA 270.00 90.00 W
F3WINDOW3 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F3 SWALL SWA 180.00 90.00 S
F3WINDOW4 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F3 NWALL NWA 0.00 90.00 N
F3WINDOW6 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F3 WWALL NWA 270.00 90.00 W
F3WINDOW8 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F3 EWALL SEA 90.00 90.00 E
F3WINDOW1 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F3 SWALL SEA 180.00 90.00 S
F3WINDOW5 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F3 NWALL NEA 0.00 90.00 N
F3WINDOW7 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F3 EWALL NEA 90.00 90.00 E
F3WINDOW9 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F3 NWALL N1A 0.00 90.00 N
F3WINDOW10 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F3 NWALL N2A 0.00 90.00 N
F3WINDOW11 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F3 SWALL S1A 180.00 90.00 S
F3WINDOW12 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F3 SWALL S2A 180.00 90.00 S
F3WINDOW13 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F3 WWALL C 270.00 90.00 W
F3WINDOW14 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F3 EWALL C 90.00 90.00 E
F4WINDOW2 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F4 WWALL SWA 270.00 90.00 W
F4WINDOW3 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F4 SWALL SWA 180.00 90.00 S
F4WINDOW4 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F4 NWALL NWA 0.00 90.00 N
F4WINDOW6 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F4 WWALL NWA 270.00 90.00 W
F4WINDOW8 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F4 EWALL SEA 90.00 90.00 E
F4WINDOW1 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F4 SWALL SEA 180.00 90.00 S
F4WINDOW5 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F4 NWALL NEA 0.00 90.00 N
F4WINDOW7 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F4 EWALL NEA 90.00 90.00 E
F4WINDOW9 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F4 NWALL N1A 0.00 90.00 N
F4WINDOW10 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F4 NWALL N2A 0.00 90.00 N
F4WINDOW11 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F4 SWALL S1A 180.00 90.00 S
F4WINDOW12 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F4 SWALL S2A 180.00 90.00 S
F4WINDOW13 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F4 WWALL C 270.00 90.00 W
F4WINDOW14 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F4 EWALL C 90.00 90.00 E
MWINDOW2 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No M WWALL SWA 270.00 90.00 W
MWINDOW3 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No M SWALL SWA 180.00 90.00 S
MWINDOW4 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No M NWALL NWA 0.00 90.00 N
MWINDOW6 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No M WWALL NWA 270.00 90.00 W
MWINDOW8 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No M EWALL SEA 90.00 90.00 E
MWINDOW1 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No M SWALL SEA 180.00 90.00 S
MWINDOW5 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No M NWALL NEA 0.00 90.00 N
MWINDOW7 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No M EWALL NEA 90.00 90.00 E
MWINDOW9 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No M NWALL N1A 0.00 90.00 N
MWINDOW10 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No M NWALL N2A 0.00 90.00 N
MWINDOW11 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No M SWALL S1A 180.00 90.00 S
MWINDOW12 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No M SWALL S2A 180.00 90.00 S
MWINDOW13 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No M WWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No M EWALL C 90.00 90.00 E
F6WINDOW2 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F6 WWALL SWA 270.00 90.00 W
F6WINDOW3 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F6 SWALL SWA 180.00 90.00 S
F6WINDOW4 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F6 NWALL NWA 0.00 90.00 N
F6WINDOW6 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F6 WWALL NWA 270.00 90.00 W
F6WINDOW8 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F6 EWALL SEA 90.00 90.00 E
F6WINDOW1 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F6 SWALL SEA 180.00 90.00 S
F6WINDOW5 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F6 NWALL NEA 0.00 90.00 N
F6WINDOW7 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F6 EWALL NEA 90.00 90.00 E
F6WINDOW9 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F6 NWALL N1A 0.00 90.00 N
F6WINDOW10 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F6 NWALL N2A 0.00 90.00 N
F6WINDOW11 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F6 SWALL S1A 180.00 90.00 S
F6WINDOW12 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F6 SWALL S2A 180.00 90.00 S
F6WINDOW13 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F6 WWALL C 270.00 90.00 W
F6WINDOW14 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F6 EWALL C 90.00 90.00 E
F7WINDOW2 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F7 WWALL SWA 270.00 90.00 W
F7WINDOW3 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F7 SWALL SWA 180.00 90.00 S
F7WINDOW4 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F7 NWALL NWA 0.00 90.00 N
F7WINDOW6 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F7 WWALL NWA 270.00 90.00 W
F7WINDOW8 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F7 EWALL SEA 90.00 90.00 E
F7WINDOW1 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F7 SWALL SEA 180.00 90.00 S
F7WINDOW5 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F7 NWALL NEA 0.00 90.00 N
F7WINDOW7 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F7 EWALL NEA 90.00 90.00 E
F7WINDOW9 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F7 NWALL N1A 0.00 90.00 N
F7WINDOW10 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F7 NWALL N2A 0.00 90.00 N
F7WINDOW11 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F7 SWALL S1A 180.00 90.00 S
F7WINDOW12 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F7 SWALL S2A 180.00 90.00 S
F7WINDOW13 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F7 WWALL C 270.00 90.00 W
F7WINDOW14 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F7 EWALL C 90.00 90.00 E
F8WINDOW2 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F8 WWALL SWA 270.00 90.00 W
F8WINDOW3 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F8 SWALL SWA 180.00 90.00 S
F8WINDOW4 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F8 NWALL NWA 0.00 90.00 N
F8WINDOW6 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F8 WWALL NWA 270.00 90.00 W
F8WINDOW8 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F8 EWALL SEA 90.00 90.00 E
F8WINDOW1 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F8 SWALL SEA 180.00 90.00 S
F8WINDOW5 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F8 NWALL NEA 0.00 90.00 N
F8WINDOW7 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F8 EWALL NEA 90.00 90.00 E
F8WINDOW9 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F8 NWALL N1A 0.00 90.00 N
F8WINDOW10 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F8 NWALL N2A 0.00 90.00 N
F8WINDOW11 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F8 SWALL S1A 180.00 90.00 S
F8WINDOW12 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F8 SWALL S2A 180.00 90.00 S
F8WINDOW13 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F8 WWALL C 270.00 90.00 W
F8WINDOW14 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F8 EWALL C 90.00 90.00 E
F9WINDOW2 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F9 WWALL SWA 270.00 90.00 W
F9WINDOW3 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F9 SWALL SWA 180.00 90.00 S
F9WINDOW4 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F9 NWALL NWA 0.00 90.00 N
F9WINDOW6 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F9 WWALL NWA 270.00 90.00 W
F9WINDOW8 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F9 EWALL SEA 90.00 90.00 E
F9WINDOW1 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F9 SWALL SEA 180.00 90.00 S
F9WINDOW5 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F9 NWALL NEA 0.00 90.00 N
F9WINDOW7 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F9 EWALL NEA 90.00 90.00 E
F9WINDOW9 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F9 NWALL N1A 0.00 90.00 N
F9WINDOW10 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F9 NWALL N2A 0.00 90.00 N
F9WINDOW11 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F9 SWALL S1A 180.00 90.00 S
F9WINDOW12 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F9 SWALL S2A 180.00 90.00 S
F9WINDOW13 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F9 WWALL C 270.00 90.00 W
F9WINDOW14 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F9 EWALL C 90.00 90.00 E
TWINDOW2 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No T WWALL SWA 270.00 90.00 W
TWINDOW3 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No T SWALL SWA 180.00 90.00 S
TWINDOW4 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No T NWALL NWA 0.00 90.00 N
TWINDOW6 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No T WWALL NWA 270.00 90.00 W
TWINDOW8 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No T EWALL SEA 90.00 90.00 E
TWINDOW1 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No T SWALL SEA 180.00 90.00 S
TWINDOW5 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No T NWALL NEA 0.00 90.00 N
TWINDOW7 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No T EWALL NEA 90.00 90.00 E
TWINDOW9 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No T NWALL N1A 0.00 90.00 N
TWINDOW10 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No T NWALL N2A 0.00 90.00 N
TWINDOW11 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No T SWALL S1A 180.00 90.00 S
TWINDOW12 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No T SWALL S2A 180.00 90.00 S
TWINDOW13 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No T WWALL C 270.00 90.00 W
TWINDOW14 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No T EWALL C 90.00 90.00 E
Total or Average           1150.39 2.848 0.287 0.200              
North Total or Average           423.59 2.848 0.287 0.200              
Non-North Total or Average           726.80 2.848 0.287 0.200              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:07

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:07

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
G SW APARTMENT_LIGHTS_HARDWIRED G SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G NW APARTMENT_LIGHTS_HARDWIRED G NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
OFFICE_LIGHTS_HARDWIRED OFFICE 14.7681 88.25 1303.26 GeneralLights LTG_OFF_SCH 62.05 168.00 61.07 0.0000 Y 14.94
G NE APARTMENT_LIGHTS_HARDWIRED G NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G N1 APARTMENT_LIGHTS_HARDWIRED G N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G N2 APARTMENT_LIGHTS_HARDWIRED G N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G S1 APARTMENT_LIGHTS_HARDWIRED G S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G S2 APARTMENT_LIGHTS_HARDWIRED G S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G CORRIDOR_LIGHTS_HARDWIRED G CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F2 SW APARTMENT_LIGHTS_HARDWIRED F2 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 NW APARTMENT_LIGHTS_HARDWIRED F2 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 SE APARTMENT_LIGHTS_HARDWIRED F2 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 NE APARTMENT_LIGHTS_HARDWIRED F2 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 N1 APARTMENT_LIGHTS_HARDWIRED F2 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 N2 APARTMENT_LIGHTS_HARDWIRED F2 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 S1 APARTMENT_LIGHTS_HARDWIRED F2 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 S2 APARTMENT_LIGHTS_HARDWIRED F2 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 CORRIDOR_LIGHTS_HARDWIRED F2 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F3 SW APARTMENT_LIGHTS_HARDWIRED F3 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 NW APARTMENT_LIGHTS_HARDWIRED F3 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 SE APARTMENT_LIGHTS_HARDWIRED F3 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 NE APARTMENT_LIGHTS_HARDWIRED F3 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 N1 APARTMENT_LIGHTS_HARDWIRED F3 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 N2 APARTMENT_LIGHTS_HARDWIRED F3 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 S1 APARTMENT_LIGHTS_HARDWIRED F3 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 S2 APARTMENT_LIGHTS_HARDWIRED F3 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 CORRIDOR_LIGHTS_HARDWIRED F3 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F4 SW APARTMENT_LIGHTS_HARDWIRED F4 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 NW APARTMENT_LIGHTS_HARDWIRED F4 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 SE APARTMENT_LIGHTS_HARDWIRED F4 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 NE APARTMENT_LIGHTS_HARDWIRED F4 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 N1 APARTMENT_LIGHTS_HARDWIRED F4 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 N2 APARTMENT_LIGHTS_HARDWIRED F4 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 S1 APARTMENT_LIGHTS_HARDWIRED F4 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 S2 APARTMENT_LIGHTS_HARDWIRED F4 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 CORRIDOR_LIGHTS_HARDWIRED F4 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
M SW APARTMENT_LIGHTS_HARDWIRED M SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M NW APARTMENT_LIGHTS_HARDWIRED M NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M SE APARTMENT_LIGHTS_HARDWIRED M SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M NE APARTMENT_LIGHTS_HARDWIRED M NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M N1 APARTMENT_LIGHTS_HARDWIRED M N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M N2 APARTMENT_LIGHTS_HARDWIRED M N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M S1 APARTMENT_LIGHTS_HARDWIRED M S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M S2 APARTMENT_LIGHTS_HARDWIRED M S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M CORRIDOR_LIGHTS_HARDWIRED M CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F6 SW APARTMENT_LIGHTS_HARDWIRED F6 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 NW APARTMENT_LIGHTS_HARDWIRED F6 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 SE APARTMENT_LIGHTS_HARDWIRED F6 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 NE APARTMENT_LIGHTS_HARDWIRED F6 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 N1 APARTMENT_LIGHTS_HARDWIRED F6 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 N2 APARTMENT_LIGHTS_HARDWIRED F6 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 S1 APARTMENT_LIGHTS_HARDWIRED F6 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 S2 APARTMENT_LIGHTS_HARDWIRED F6 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 CORRIDOR_LIGHTS_HARDWIRED F6 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F7 SW APARTMENT_LIGHTS_HARDWIRED F7 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 NW APARTMENT_LIGHTS_HARDWIRED F7 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 SE APARTMENT_LIGHTS_HARDWIRED F7 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 NE APARTMENT_LIGHTS_HARDWIRED F7 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 N1 APARTMENT_LIGHTS_HARDWIRED F7 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 N2 APARTMENT_LIGHTS_HARDWIRED F7 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 S1 APARTMENT_LIGHTS_HARDWIRED F7 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 S2 APARTMENT_LIGHTS_HARDWIRED F7 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 CORRIDOR_LIGHTS_HARDWIRED F7 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F8 SW APARTMENT_LIGHTS_HARDWIRED F8 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 NW APARTMENT_LIGHTS_HARDWIRED F8 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 SE APARTMENT_LIGHTS_HARDWIRED F8 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 NE APARTMENT_LIGHTS_HARDWIRED F8 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 N1 APARTMENT_LIGHTS_HARDWIRED F8 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 N2 APARTMENT_LIGHTS_HARDWIRED F8 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 S1 APARTMENT_LIGHTS_HARDWIRED F8 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 S2 APARTMENT_LIGHTS_HARDWIRED F8 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 CORRIDOR_LIGHTS_HARDWIRED F8 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F9 SW APARTMENT_LIGHTS_HARDWIRED F9 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 NW APARTMENT_LIGHTS_HARDWIRED F9 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 SE APARTMENT_LIGHTS_HARDWIRED F9 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 NE APARTMENT_LIGHTS_HARDWIRED F9 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 N1 APARTMENT_LIGHTS_HARDWIRED F9 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 N2 APARTMENT_LIGHTS_HARDWIRED F9 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 S1 APARTMENT_LIGHTS_HARDWIRED F9 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 S2 APARTMENT_LIGHTS_HARDWIRED F9 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 CORRIDOR_LIGHTS_HARDWIRED F9 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
T SW APARTMENT_LIGHTS_HARDWIRED T SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T NW APARTMENT_LIGHTS_HARDWIRED T NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T SE APARTMENT_LIGHTS_HARDWIRED T SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T NE APARTMENT_LIGHTS_HARDWIRED T NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T N1 APARTMENT_LIGHTS_HARDWIRED T N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T N2 APARTMENT_LIGHTS_HARDWIRED T N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T S1 APARTMENT_LIGHTS_HARDWIRED T S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T S2 APARTMENT_LIGHTS_HARDWIRED T S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T CORRIDOR_LIGHTS_HARDWIRED T CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
G SW APARTMENT_LIGHTS_PLUGIN G SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G NW APARTMENT_LIGHTS_PLUGIN G NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
OFFICE_LIGHTS_PLUGIN OFFICE 14.7681 88.25 1303.26 GeneralLights-plugin LTG_OFF_SCH 62.05 168.00 61.07 0.0000 Y 14.94
G NE APARTMENT_LIGHTS_PLUGIN G NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G N1 APARTMENT_LIGHTS_PLUGIN G N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G N2 APARTMENT_LIGHTS_PLUGIN G N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G S1 APARTMENT_LIGHTS_PLUGIN G S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G S2 APARTMENT_LIGHTS_PLUGIN G S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 SW APARTMENT_LIGHTS_PLUGIN F2 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 NW APARTMENT_LIGHTS_PLUGIN F2 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 SE APARTMENT_LIGHTS_PLUGIN F2 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 NE APARTMENT_LIGHTS_PLUGIN F2 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 N1 APARTMENT_LIGHTS_PLUGIN F2 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 N2 APARTMENT_LIGHTS_PLUGIN F2 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 S1 APARTMENT_LIGHTS_PLUGIN F2 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 S2 APARTMENT_LIGHTS_PLUGIN F2 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 SW APARTMENT_LIGHTS_PLUGIN F3 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 NW APARTMENT_LIGHTS_PLUGIN F3 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 SE APARTMENT_LIGHTS_PLUGIN F3 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 NE APARTMENT_LIGHTS_PLUGIN F3 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 N1 APARTMENT_LIGHTS_PLUGIN F3 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 N2 APARTMENT_LIGHTS_PLUGIN F3 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 S1 APARTMENT_LIGHTS_PLUGIN F3 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 S2 APARTMENT_LIGHTS_PLUGIN F3 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 SW APARTMENT_LIGHTS_PLUGIN F4 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 NW APARTMENT_LIGHTS_PLUGIN F4 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 SE APARTMENT_LIGHTS_PLUGIN F4 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 NE APARTMENT_LIGHTS_PLUGIN F4 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 N1 APARTMENT_LIGHTS_PLUGIN F4 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 N2 APARTMENT_LIGHTS_PLUGIN F4 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 S1 APARTMENT_LIGHTS_PLUGIN F4 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 S2 APARTMENT_LIGHTS_PLUGIN F4 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M SW APARTMENT_LIGHTS_PLUGIN M SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M NW APARTMENT_LIGHTS_PLUGIN M NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M SE APARTMENT_LIGHTS_PLUGIN M SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M NE APARTMENT_LIGHTS_PLUGIN M NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M N1 APARTMENT_LIGHTS_PLUGIN M N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M N2 APARTMENT_LIGHTS_PLUGIN M N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M S1 APARTMENT_LIGHTS_PLUGIN M S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M S2 APARTMENT_LIGHTS_PLUGIN M S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M CORRIDOR_LIGHTS_PLUGIN M CORRIDOR 6.7128 77.66 521.30 GeneralLights-plugin LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F6 SW APARTMENT_LIGHTS_PLUGIN F6 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 NW APARTMENT_LIGHTS_PLUGIN F6 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 SE APARTMENT_LIGHTS_PLUGIN F6 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 NE APARTMENT_LIGHTS_PLUGIN F6 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 N1 APARTMENT_LIGHTS_PLUGIN F6 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 N2 APARTMENT_LIGHTS_PLUGIN F6 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 S1 APARTMENT_LIGHTS_PLUGIN F6 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 S2 APARTMENT_LIGHTS_PLUGIN F6 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 SW APARTMENT_LIGHTS_PLUGIN F7 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 NW APARTMENT_LIGHTS_PLUGIN F7 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 SE APARTMENT_LIGHTS_PLUGIN F7 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 NE APARTMENT_LIGHTS_PLUGIN F7 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 N1 APARTMENT_LIGHTS_PLUGIN F7 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 N2 APARTMENT_LIGHTS_PLUGIN F7 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 S1 APARTMENT_LIGHTS_PLUGIN F7 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 S2 APARTMENT_LIGHTS_PLUGIN F7 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 SW APARTMENT_LIGHTS_PLUGIN F8 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 NW APARTMENT_LIGHTS_PLUGIN F8 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 SE APARTMENT_LIGHTS_PLUGIN F8 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 NE APARTMENT_LIGHTS_PLUGIN F8 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 N1 APARTMENT_LIGHTS_PLUGIN F8 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 N2 APARTMENT_LIGHTS_PLUGIN F8 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 S1 APARTMENT_LIGHTS_PLUGIN F8 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 S2 APARTMENT_LIGHTS_PLUGIN F8 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 SW APARTMENT_LIGHTS_PLUGIN F9 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 NW APARTMENT_LIGHTS_PLUGIN F9 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 SE APARTMENT_LIGHTS_PLUGIN F9 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 NE APARTMENT_LIGHTS_PLUGIN F9 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 N1 APARTMENT_LIGHTS_PLUGIN F9 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 N2 APARTMENT_LIGHTS_PLUGIN F9 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 S1 APARTMENT_LIGHTS_PLUGIN F9 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 S2 APARTMENT_LIGHTS_PLUGIN F9 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T SW APARTMENT_LIGHTS_PLUGIN T SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T NW APARTMENT_LIGHTS_PLUGIN T NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T SE APARTMENT_LIGHTS_PLUGIN T SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T NE APARTMENT_LIGHTS_PLUGIN T NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T N1 APARTMENT_LIGHTS_PLUGIN T N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T N2 APARTMENT_LIGHTS_PLUGIN T N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T S1 APARTMENT_LIGHTS_PLUGIN T S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T S2 APARTMENT_LIGHTS_PLUGIN T S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
Interior Lighting Total   2.2679 14974.03 33959.19               296.56


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 10364.00 AstronomicalClock -   83.65 83.65 162.73
Exterior Lighting Total 10364.00           162.73



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:07

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
CENTRAL BOILER Boiler:HotWater 186493.07 0.75    
CENTRAL TOWER EvaporativeFluidCooler:SingleSpeed 149194.46      


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
HEAT PUMP COOLING MODE AIRLOOP G SW Coil:Cooling:WaterToAirHeatPump:EquationFit   2563.84 1990.97 572.87 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NW Coil:Cooling:WaterToAirHeatPump:EquationFit   2112.46 1645.03 467.43 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP OFFICE Coil:Cooling:WaterToAirHeatPump:EquationFit   4156.08 3239.54 916.53 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NE Coil:Cooling:WaterToAirHeatPump:EquationFit   1477.02 1157.70 319.32 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   931.68 723.93 207.74 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   912.56 709.13 203.43 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1700.88 1308.59 392.28 0.77 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1787.39 1376.63 410.76 0.77 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   3237.00 2525.49 711.51 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   2695.86 2105.63 590.23 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   3200.43 2492.51 707.92 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   1984.64 1561.08 423.56 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1344.49 1046.79 297.71 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1328.10 1034.03 294.08 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2236.36 1730.31 506.05 0.77 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2267.91 1755.08 512.82 0.77 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   3246.91 2535.19 711.72 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   2718.42 2125.19 593.23 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   2943.71 2292.76 650.94 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2017.99 1589.16 428.83 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1400.14 1091.27 308.87 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1383.98 1078.68 305.30 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2284.07 1768.96 515.11 0.77 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2297.37 1779.40 517.97 0.77 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   3240.61 2531.64 708.96 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   2715.17 2124.00 591.17 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   2921.19 2276.42 644.77 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2024.77 1593.31 431.47 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1416.45 1104.80 311.65 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1400.53 1092.39 308.15 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2294.27 1777.83 516.44 0.77 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2304.78 1786.09 518.70 0.77 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SW Coil:Cooling:WaterToAirHeatPump:EquationFit   3260.58 2548.45 712.13 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NW Coil:Cooling:WaterToAirHeatPump:EquationFit   2737.36 2142.49 594.87 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SE Coil:Cooling:WaterToAirHeatPump:EquationFit   2948.26 2298.77 649.49 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2047.31 1612.02 435.28 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1451.87 1133.08 318.79 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1436.15 1120.82 315.33 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2325.72 1803.23 522.49 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2335.83 1811.16 524.66 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   3216.33 2511.89 704.43 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   2684.22 2101.68 582.54 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   2903.81 2264.73 639.08 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   1995.95 1572.43 423.52 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1413.58 1103.74 309.84 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1398.17 1091.71 306.46 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2282.63 1769.97 512.67 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2292.69 1777.86 514.82 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   3192.94 2494.32 698.62 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   2660.65 2083.95 576.70 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   2887.09 2252.36 634.73 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   1973.20 1555.22 417.98 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1401.45 1094.73 306.72 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1386.26 1082.87 303.39 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2266.59 1757.86 508.72 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2276.63 1765.76 510.88 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   3185.00 2488.79 696.21 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   2652.90 2078.54 574.36 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   2884.61 2251.09 633.51 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   1965.16 1549.50 415.67 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1403.70 1096.89 306.81 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1388.72 1085.19 303.53 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2264.91 1756.99 507.91 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2274.97 1764.90 510.07 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   3246.27 2540.34 705.94 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   2726.00 2136.57 589.43 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   2944.46 2297.78 646.68 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   1988.83 1565.90 422.93 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1476.09 1153.79 322.30 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1461.16 1142.13 319.03 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2311.99 1794.40 517.59 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2323.24 1803.24 520.00 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4035.11 3156.96 878.15 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3358.57 2631.20 727.37 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SE Coil:Cooling:WaterToAirHeatPump:EquationFit   3661.84 2863.28 798.56 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2508.57 1972.57 536.00 0.79 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2034.57 1575.70 458.87 0.77 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2035.77 1576.65 459.12 0.77 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3113.02 2424.04 688.98 0.78 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3123.67 2432.40 691.27 0.78 0.00    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
None            


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
HEAT PUMP HEATING MODE AIRLOOP G SW Coil:Heating:WaterToAirHeatPump:EquationFit   2563.84 0.00
HEAT PUMP HEATING MODE AIRLOOP G NW Coil:Heating:WaterToAirHeatPump:EquationFit   2112.46 0.00
HEAT PUMP HEATING MODE AIRLOOP OFFICE Coil:Heating:WaterToAirHeatPump:EquationFit   4156.08 0.00
HEAT PUMP HEATING MODE AIRLOOP G NE Coil:Heating:WaterToAirHeatPump:EquationFit   1477.02 0.00
HEAT PUMP HEATING MODE AIRLOOP G N1 Coil:Heating:WaterToAirHeatPump:EquationFit   931.68 0.00
HEAT PUMP HEATING MODE AIRLOOP G N2 Coil:Heating:WaterToAirHeatPump:EquationFit   912.56 0.00
HEAT PUMP HEATING MODE AIRLOOP G S1 Coil:Heating:WaterToAirHeatPump:EquationFit   1700.88 0.00
HEAT PUMP HEATING MODE AIRLOOP G S2 Coil:Heating:WaterToAirHeatPump:EquationFit   1787.39 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SW Coil:Heating:WaterToAirHeatPump:EquationFit   3237.00 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NW Coil:Heating:WaterToAirHeatPump:EquationFit   2695.86 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SE Coil:Heating:WaterToAirHeatPump:EquationFit   3200.43 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NE Coil:Heating:WaterToAirHeatPump:EquationFit   1984.64 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1344.49 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1328.10 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2236.36 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2267.91 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SW Coil:Heating:WaterToAirHeatPump:EquationFit   3246.91 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NW Coil:Heating:WaterToAirHeatPump:EquationFit   2718.42 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SE Coil:Heating:WaterToAirHeatPump:EquationFit   2943.71 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2017.99 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1400.14 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1383.98 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2284.07 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2297.37 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SW Coil:Heating:WaterToAirHeatPump:EquationFit   3240.61 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NW Coil:Heating:WaterToAirHeatPump:EquationFit   2715.17 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SE Coil:Heating:WaterToAirHeatPump:EquationFit   2921.19 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2024.77 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1416.45 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1400.53 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2294.27 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2304.78 0.00
HEAT PUMP HEATING MODE AIRLOOP M SW Coil:Heating:WaterToAirHeatPump:EquationFit   3260.58 0.00
HEAT PUMP HEATING MODE AIRLOOP M NW Coil:Heating:WaterToAirHeatPump:EquationFit   2737.36 0.00
HEAT PUMP HEATING MODE AIRLOOP M SE Coil:Heating:WaterToAirHeatPump:EquationFit   2948.26 0.00
HEAT PUMP HEATING MODE AIRLOOP M NE Coil:Heating:WaterToAirHeatPump:EquationFit   2047.31 0.00
HEAT PUMP HEATING MODE AIRLOOP M N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1451.87 0.00
HEAT PUMP HEATING MODE AIRLOOP M N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1436.15 0.00
HEAT PUMP HEATING MODE AIRLOOP M S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2325.72 0.00
HEAT PUMP HEATING MODE AIRLOOP M S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2335.83 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SW Coil:Heating:WaterToAirHeatPump:EquationFit   3216.33 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NW Coil:Heating:WaterToAirHeatPump:EquationFit   2684.22 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SE Coil:Heating:WaterToAirHeatPump:EquationFit   2903.81 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NE Coil:Heating:WaterToAirHeatPump:EquationFit   1995.95 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1413.58 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1398.17 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2282.63 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2292.69 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SW Coil:Heating:WaterToAirHeatPump:EquationFit   3192.94 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NW Coil:Heating:WaterToAirHeatPump:EquationFit   2660.65 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SE Coil:Heating:WaterToAirHeatPump:EquationFit   2887.09 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NE Coil:Heating:WaterToAirHeatPump:EquationFit   1973.20 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1401.45 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1386.26 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2266.59 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2276.63 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SW Coil:Heating:WaterToAirHeatPump:EquationFit   3185.00 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NW Coil:Heating:WaterToAirHeatPump:EquationFit   2652.90 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SE Coil:Heating:WaterToAirHeatPump:EquationFit   2884.61 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NE Coil:Heating:WaterToAirHeatPump:EquationFit   1965.16 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1403.70 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1388.72 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2264.91 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2274.97 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SW Coil:Heating:WaterToAirHeatPump:EquationFit   3246.27 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NW Coil:Heating:WaterToAirHeatPump:EquationFit   2726.00 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SE Coil:Heating:WaterToAirHeatPump:EquationFit   2944.46 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NE Coil:Heating:WaterToAirHeatPump:EquationFit   1988.83 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1476.09 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1461.16 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2311.99 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2323.24 0.00
HEAT PUMP HEATING MODE AIRLOOP T SW Coil:Heating:WaterToAirHeatPump:EquationFit   4035.11 0.00
HEAT PUMP HEATING MODE AIRLOOP T NW Coil:Heating:WaterToAirHeatPump:EquationFit   3358.57 0.00
HEAT PUMP HEATING MODE AIRLOOP T SE Coil:Heating:WaterToAirHeatPump:EquationFit   3661.84 0.00
HEAT PUMP HEATING MODE AIRLOOP T NE Coil:Heating:WaterToAirHeatPump:EquationFit   2508.57 0.00
HEAT PUMP HEATING MODE AIRLOOP T N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2034.57 0.00
HEAT PUMP HEATING MODE AIRLOOP T N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2035.77 0.00
HEAT PUMP HEATING MODE AIRLOOP T S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3113.02 0.00
HEAT PUMP HEATING MODE AIRLOOP T S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3123.67 0.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW Coil:Heating:Electric   1666.56 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW Coil:Heating:Electric   1672.45 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE Coil:Heating:Electric   2242.41 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE Coil:Heating:Electric   1670.56 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 Coil:Heating:Electric   1238.05 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 Coil:Heating:Electric   1238.00 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 Coil:Heating:Electric   1227.96 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 Coil:Heating:Electric   1234.08 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW Coil:Heating:Electric   1572.32 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW Coil:Heating:Electric   1576.60 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE Coil:Heating:Electric   1589.50 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE Coil:Heating:Electric   1574.69 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW Coil:Heating:Electric   1553.36 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW Coil:Heating:Electric   1556.84 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE Coil:Heating:Electric   1554.12 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE Coil:Heating:Electric   1555.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW Coil:Heating:Electric   1574.01 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW Coil:Heating:Electric   1577.31 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE Coil:Heating:Electric   1573.04 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE Coil:Heating:Electric   1576.07 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW Coil:Heating:Electric   1578.67 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW Coil:Heating:Electric   1580.66 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE Coil:Heating:Electric   1577.75 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE Coil:Heating:Electric   1579.71 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW Coil:Heating:Electric   1640.86 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW Coil:Heating:Electric   1643.30 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE Coil:Heating:Electric   1640.17 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE Coil:Heating:Electric   1642.60 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW Coil:Heating:Electric   1680.96 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW Coil:Heating:Electric   1682.82 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE Coil:Heating:Electric   1680.49 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE Coil:Heating:Electric   1682.35 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW Coil:Heating:Electric   1722.82 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW Coil:Heating:Electric   1724.00 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE Coil:Heating:Electric   1722.57 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE Coil:Heating:Electric   1723.75 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 Coil:Heating:Electric   1136.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW Coil:Heating:Electric   1845.30 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW Coil:Heating:Electric   1844.46 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE Coil:Heating:Electric   1845.25 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE Coil:Heating:Electric   1844.41 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 Coil:Heating:Electric   1208.35 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 Coil:Heating:Electric   1208.35 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 Coil:Heating:Electric   1208.90 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 Coil:Heating:Electric   1208.90 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW Coil:Heating:Electric   2251.22 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW Coil:Heating:Electric   2254.87 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE Coil:Heating:Electric   2251.32 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE Coil:Heating:Electric   2254.97 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 Coil:Heating:Electric   1646.47 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 Coil:Heating:Electric   1646.47 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 Coil:Heating:Electric   1639.75 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 Coil:Heating:Electric   1639.75 1.00


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
AIRLOOP G SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 205.34 1160.84 1.00 General
AIRLOOP G NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.15 170.53 1160.84 1.00 General
AIRLOOP OFFICE SUPPLY FAN Fan:OnOff 0.54 622.50 0.29 335.23 1160.84 1.00 General
AIRLOOP G NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 121.06 1160.84 1.00 General
AIRLOOP G N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.06 74.74 1160.84 1.00 General
AIRLOOP G N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.06 73.19 1160.84 1.00 General
AIRLOOP G S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.11 132.98 1160.84 1.00 General
AIRLOOP G S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 140.15 1160.84 1.00 General
AIRLOOP F2 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 262.36 1160.84 1.00 General
AIRLOOP F2 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 219.28 1160.84 1.00 General
AIRLOOP F2 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 258.17 1160.84 1.00 General
AIRLOOP F2 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 163.89 1160.84 1.00 General
AIRLOOP F2 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.09 108.74 1160.84 1.00 General
AIRLOOP F2 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.09 107.40 1160.84 1.00 General
AIRLOOP F2 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.15 177.39 1160.84 1.00 General
AIRLOOP F2 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 180.00 1160.84 1.00 General
AIRLOOP F3 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 263.48 1160.84 1.00 General
AIRLOOP F3 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 221.44 1160.84 1.00 General
AIRLOOP F3 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 237.20 1160.84 1.00 General
AIRLOOP F3 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 166.96 1160.84 1.00 General
AIRLOOP F3 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 113.48 1160.84 1.00 General
AIRLOOP F3 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 112.16 1160.84 1.00 General
AIRLOOP F3 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 181.53 1160.84 1.00 General
AIRLOOP F3 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 182.63 1160.84 1.00 General
AIRLOOP F4 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 263.18 1160.84 1.00 General
AIRLOOP F4 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 221.39 1160.84 1.00 General
AIRLOOP F4 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 235.54 1160.84 1.00 General
AIRLOOP F4 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 167.00 1160.84 1.00 General
AIRLOOP F4 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 114.95 1160.84 1.00 General
AIRLOOP F4 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 113.64 1160.84 1.00 General
AIRLOOP F4 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 182.51 1160.84 1.00 General
AIRLOOP F4 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 183.38 1160.84 1.00 General
AIRLOOP M SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 265.02 1160.84 1.00 General
AIRLOOP M NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 223.39 1160.84 1.00 General
AIRLOOP M SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 237.96 1160.84 1.00 General
AIRLOOP M NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.15 169.03 1160.84 1.00 General
AIRLOOP M N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 117.96 1160.84 1.00 General
AIRLOOP M N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 116.67 1160.84 1.00 General
AIRLOOP M S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 185.23 1160.84 1.00 General
AIRLOOP M S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 186.06 1160.84 1.00 General
AIRLOOP F6 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 260.76 1160.84 1.00 General
AIRLOOP F6 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 219.14 1160.84 1.00 General
AIRLOOP F6 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 234.41 1160.84 1.00 General
AIRLOOP F6 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 164.88 1160.84 1.00 General
AIRLOOP F6 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 114.90 1160.84 1.00 General
AIRLOOP F6 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 113.63 1160.84 1.00 General
AIRLOOP F6 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 181.75 1160.84 1.00 General
AIRLOOP F6 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 182.58 1160.84 1.00 General
AIRLOOP F7 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 258.95 1160.84 1.00 General
AIRLOOP F7 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 217.31 1160.84 1.00 General
AIRLOOP F7 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 233.15 1160.84 1.00 General
AIRLOOP F7 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 163.10 1160.84 1.00 General
AIRLOOP F7 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 113.97 1160.84 1.00 General
AIRLOOP F7 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 112.73 1160.84 1.00 General
AIRLOOP F7 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 180.50 1160.84 1.00 General
AIRLOOP F7 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 181.33 1160.84 1.00 General
AIRLOOP F8 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 258.40 1160.84 1.00 General
AIRLOOP F8 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 216.77 1160.84 1.00 General
AIRLOOP F8 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 233.05 1160.84 1.00 General
AIRLOOP F8 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 162.53 1160.84 1.00 General
AIRLOOP F8 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 114.22 1160.84 1.00 General
AIRLOOP F8 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 112.99 1160.84 1.00 General
AIRLOOP F8 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 180.43 1160.84 1.00 General
AIRLOOP F8 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 181.27 1160.84 1.00 General
AIRLOOP F9 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 264.33 1160.84 1.00 General
AIRLOOP F9 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 222.93 1160.84 1.00 General
AIRLOOP F9 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 237.85 1160.84 1.00 General
AIRLOOP F9 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 163.81 1160.84 1.00 General
AIRLOOP F9 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 120.23 1160.84 1.00 General
AIRLOOP F9 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 119.00 1160.84 1.00 General
AIRLOOP F9 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 184.40 1160.84 1.00 General
AIRLOOP F9 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 185.33 1160.84 1.00 General
AIRLOOP T SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 328.82 1160.84 1.00 General
AIRLOOP T NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 274.41 1160.84 1.00 General
AIRLOOP T SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 297.75 1160.84 1.00 General
AIRLOOP T NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 206.33 1160.84 1.00 General
AIRLOOP T N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 161.19 1160.84 1.00 General
AIRLOOP T N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 161.29 1160.84 1.00 General
AIRLOOP T S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 250.85 1160.84 1.00 General
AIRLOOP T S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 251.73 1160.84 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
SHWSYS1 PUMP Pump:ConstantSpeed Intermittent 29891.00 0.0003 36.93 127739.32 0.30
PLANT CIRC PUMP Pump:ConstantSpeed Intermittent 224180.02 0.0041 1295.38 319344.75 0.90


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
SHWSYS1 WATER HEATER WaterHeater:Mixed 2.27 175842.64 0.80 0.00 0.00



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:07

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1882.20 2258.64 0.147 0.177 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 27.92 0.00771
G NW APARTMENT 1563.16 1875.79 0.122 0.147 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 17:30:00 26.69 0.00771
OFFICE 3072.83 3687.40 0.241 0.289 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:15:00 27.98 0.00771
G NE APARTMENT 1109.63 1331.56 0.087 0.104 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 10:15:00 25.39 0.00771
G N1 APARTMENT 685.11 822.13 0.054 0.064 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 25.62 0.00771
G N2 APARTMENT 670.89 805.07 0.053 0.063 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 25.62 0.00771
G S1 APARTMENT 1218.89 1462.67 0.095 0.115 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 28.09 0.00771
G S2 APARTMENT 1284.65 1541.58 0.101 0.121 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 28.09 0.00771
F2 SW APARTMENT 2404.84 2885.81 0.188 0.226 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 16:15:00 27.62 0.00771
F2 NW APARTMENT 2009.96 2411.95 0.157 0.189 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 17:30:00 26.69 0.00771
F2 SE APARTMENT 2366.49 2839.79 0.185 0.222 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 28.09 0.00771
F2 NE APARTMENT 1502.29 1802.75 0.118 0.141 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 10:15:00 25.39 0.00771
F2 N1 APARTMENT 996.76 1196.11 0.078 0.094 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 25.62 0.00771
F2 N2 APARTMENT 984.46 1181.36 0.077 0.093 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 25.62 0.00771
F2 S1 APARTMENT 1626.01 1951.21 0.127 0.153 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 28.19 0.00771
F2 S2 APARTMENT 1649.95 1979.94 0.129 0.155 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 28.19 0.00771
F3 SW APARTMENT 2415.17 2898.20 0.189 0.227 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 16:15:00 27.62 0.00771
F3 NW APARTMENT 2029.79 2435.74 0.159 0.191 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 17:30:00 26.69 0.00771
F3 SE APARTMENT 2174.21 2609.05 0.170 0.204 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 28.09 0.00771
F3 NE APARTMENT 1530.39 1836.46 0.120 0.144 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 10:15:00 25.39 0.00771
F3 N1 APARTMENT 1040.18 1248.21 0.081 0.098 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 25.62 0.00771
F3 N2 APARTMENT 1028.04 1233.65 0.081 0.097 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 25.62 0.00771
F3 S1 APARTMENT 1663.94 1996.73 0.130 0.156 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 28.19 0.00771
F3 S2 APARTMENT 1674.04 2008.84 0.131 0.157 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 28.19 0.00771
F4 SW APARTMENT 2412.41 2894.90 0.189 0.227 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 16:15:00 27.62 0.00771
F4 NW APARTMENT 2029.29 2435.15 0.159 0.191 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 17:30:00 26.69 0.00771
F4 SE APARTMENT 2159.06 2590.87 0.169 0.203 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 28.09 0.00771
F4 NE APARTMENT 1530.73 1836.87 0.120 0.144 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 10:30:00 25.71 0.00771
F4 N1 APARTMENT 1053.62 1264.34 0.083 0.099 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 25.62 0.00771
F4 N2 APARTMENT 1041.66 1249.99 0.082 0.098 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 25.62 0.00771
F4 S1 APARTMENT 1672.94 2007.53 0.131 0.157 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 28.19 0.00771
F4 S2 APARTMENT 1680.92 2017.11 0.132 0.158 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 28.19 0.00771
M SW APARTMENT 2429.22 2915.07 0.190 0.228 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 16:15:00 27.62 0.00771
M NW APARTMENT 2047.71 2457.25 0.160 0.192 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 17:30:00 26.69 0.00771
M SE APARTMENT 2181.20 2617.44 0.171 0.205 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 28.09 0.00771
M NE APARTMENT 1549.34 1859.20 0.121 0.146 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 10:30:00 25.71 0.00771
M N1 APARTMENT 1081.21 1297.45 0.085 0.102 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 25.62 0.00771
M N2 APARTMENT 1069.39 1283.26 0.084 0.101 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 25.62 0.00771
M S1 APARTMENT 1697.83 2037.40 0.133 0.160 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 28.19 0.00771
M S2 APARTMENT 1705.51 2046.61 0.134 0.160 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 28.19 0.00771
F6 SW APARTMENT 2390.19 2868.23 0.187 0.225 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 27.92 0.00771
F6 NW APARTMENT 2008.67 2410.40 0.157 0.189 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 17:30:00 26.69 0.00771
F6 SE APARTMENT 2148.71 2578.45 0.168 0.202 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 28.09 0.00771
F6 NE APARTMENT 1511.38 1813.65 0.118 0.142 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 10:30:00 25.71 0.00771
F6 N1 APARTMENT 1053.18 1263.81 0.082 0.099 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 25.62 0.00771
F6 N2 APARTMENT 1041.57 1249.89 0.082 0.098 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 25.62 0.00771
F6 S1 APARTMENT 1665.96 1999.16 0.130 0.157 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 28.19 0.00771
F6 S2 APARTMENT 1673.60 2008.32 0.131 0.157 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 28.19 0.00771
F7 SW APARTMENT 2373.58 2848.30 0.186 0.223 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 27.92 0.00771
F7 NW APARTMENT 1991.90 2390.27 0.156 0.187 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 17:30:00 26.69 0.00771
F7 SE APARTMENT 2137.12 2564.54 0.167 0.201 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 28.09 0.00771
F7 NE APARTMENT 1495.04 1794.05 0.117 0.141 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 10:30:00 25.71 0.00771
F7 N1 APARTMENT 1044.71 1253.65 0.082 0.098 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 25.62 0.00771
F7 N2 APARTMENT 1033.27 1239.93 0.081 0.097 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 25.62 0.00771
F7 S1 APARTMENT 1654.51 1985.42 0.130 0.155 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 28.19 0.00771
F7 S2 APARTMENT 1662.14 1994.57 0.130 0.156 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 28.19 0.00771
F8 SW APARTMENT 2368.58 2842.30 0.185 0.223 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 27.92 0.00771
F8 NW APARTMENT 1987.00 2384.40 0.156 0.187 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 17:30:00 26.69 0.00771
F8 SE APARTMENT 2136.22 2563.47 0.167 0.201 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 28.09 0.00771
F8 NE APARTMENT 1489.79 1787.75 0.117 0.140 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 10:30:00 25.71 0.00771
F8 N1 APARTMENT 1046.99 1256.39 0.082 0.098 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 25.62 0.00771
F8 N2 APARTMENT 1035.71 1242.85 0.081 0.097 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 25.62 0.00771
F8 S1 APARTMENT 1653.89 1984.67 0.130 0.155 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 28.19 0.00771
F8 S2 APARTMENT 1661.53 1993.84 0.130 0.156 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 28.19 0.00771
F9 SW APARTMENT 2422.90 2907.48 0.190 0.228 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 16:15:00 27.62 0.00771
F9 NW APARTMENT 2043.44 2452.12 0.160 0.192 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 17:30:00 26.69 0.00771
F9 SE APARTMENT 2180.24 2616.28 0.171 0.205 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 28.19 0.00771
F9 NE APARTMENT 1501.54 1801.85 0.118 0.141 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 10:45:00 26.03 0.00771
F9 N1 APARTMENT 1102.07 1322.48 0.086 0.104 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 25.62 0.00771
F9 N2 APARTMENT 1090.82 1308.98 0.085 0.103 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 25.62 0.00771
F9 S1 APARTMENT 1690.26 2028.31 0.132 0.159 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 28.19 0.00771
F9 S2 APARTMENT 1698.80 2038.56 0.133 0.160 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 28.19 0.00771
T SW APARTMENT 3014.05 3616.86 0.236 0.283 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 15:30:00 28.05 0.00771
T NW APARTMENT 2515.31 3018.38 0.197 0.236 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 16:45:00 27.28 0.00771
T SE APARTMENT 2729.26 3275.12 0.214 0.256 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:30:00 28.09 0.00771
T NE APARTMENT 1891.27 2269.53 0.148 0.178 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 11:00:00 26.34 0.00771
T N1 APARTMENT 1477.56 1773.07 0.116 0.139 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 14:45:00 28.30 0.00771
T N2 APARTMENT 1478.48 1774.17 0.116 0.139 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 14:30:00 28.30 0.00771
T S1 APARTMENT 2299.37 2759.24 0.180 0.216 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 28.19 0.00771
T S2 APARTMENT 2307.45 2768.94 0.181 0.217 SAN FRANCISCO INTL AP ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 28.19 0.00771


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 934.04 1120.85 0.042 0.050 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 3.80 0.00496
G NW APARTMENT 939.02 1126.83 0.042 0.050 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 09:15:00 3.80 0.00496
OFFICE 1198.48 1438.18 0.053 0.064 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 19:00:00 3.80 0.00496
G NE APARTMENT 937.43 1124.91 0.042 0.050 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 09:15:00 3.80 0.00496
G N1 APARTMENT 571.67 686.00 0.025 0.031 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 09:15:00 3.80 0.00496
G N2 APARTMENT 571.62 685.95 0.025 0.031 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 09:15:00 3.80 0.00496
G S1 APARTMENT 563.13 675.76 0.025 0.030 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 09:15:00 3.80 0.00496
G S2 APARTMENT 568.31 681.97 0.025 0.030 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 09:15:00 3.80 0.00496
F2 SW APARTMENT 854.36 1025.23 0.038 0.046 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F2 NW APARTMENT 857.98 1029.58 0.038 0.046 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F2 SE APARTMENT 868.89 1042.66 0.039 0.046 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F2 NE APARTMENT 856.37 1027.64 0.038 0.046 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F2 N1 APARTMENT 403.67 484.41 0.018 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F2 N2 APARTMENT 403.63 484.36 0.018 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F2 S1 APARTMENT 402.14 482.57 0.018 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F2 S2 APARTMENT 403.24 483.89 0.018 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F3 SW APARTMENT 838.33 1005.99 0.037 0.045 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F3 NW APARTMENT 841.27 1009.53 0.037 0.045 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F3 SE APARTMENT 838.97 1006.77 0.037 0.045 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F3 NE APARTMENT 839.96 1007.95 0.037 0.045 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F3 N1 APARTMENT 369.12 442.94 0.016 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F3 N2 APARTMENT 369.08 442.90 0.016 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F3 S1 APARTMENT 366.61 439.93 0.016 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F3 S2 APARTMENT 366.77 440.13 0.016 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F4 SW APARTMENT 855.79 1026.95 0.038 0.046 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F4 NW APARTMENT 858.58 1030.30 0.038 0.046 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F4 SE APARTMENT 854.97 1025.97 0.038 0.046 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F4 NE APARTMENT 857.53 1029.04 0.038 0.046 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F4 N1 APARTMENT 371.77 446.13 0.017 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F4 N2 APARTMENT 371.74 446.09 0.017 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F4 S1 APARTMENT 369.22 443.06 0.016 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F4 S2 APARTMENT 369.22 443.06 0.016 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
M SW APARTMENT 859.74 1031.68 0.038 0.046 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
M NW APARTMENT 861.42 1033.70 0.038 0.046 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
M SE APARTMENT 858.96 1030.75 0.038 0.046 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
M NE APARTMENT 860.61 1032.74 0.038 0.046 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
M N1 APARTMENT 365.25 438.30 0.016 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
M N2 APARTMENT 365.23 438.28 0.016 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
M S1 APARTMENT 363.77 436.53 0.016 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
M S2 APARTMENT 363.76 436.51 0.016 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F6 SW APARTMENT 912.33 1094.80 0.041 0.049 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F6 NW APARTMENT 914.39 1097.27 0.041 0.049 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F6 SE APARTMENT 911.74 1094.09 0.041 0.049 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F6 NE APARTMENT 913.80 1096.56 0.041 0.049 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F6 N1 APARTMENT 405.26 486.31 0.018 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F6 N2 APARTMENT 405.24 486.29 0.018 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F6 S1 APARTMENT 403.38 484.06 0.018 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F6 S2 APARTMENT 403.37 484.04 0.018 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F7 SW APARTMENT 946.24 1135.49 0.042 0.051 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F7 NW APARTMENT 947.81 1137.37 0.042 0.051 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F7 SE APARTMENT 945.85 1135.02 0.042 0.051 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F7 NE APARTMENT 947.42 1136.90 0.042 0.051 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F7 N1 APARTMENT 429.46 515.36 0.019 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F7 N2 APARTMENT 429.45 515.34 0.019 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F7 S1 APARTMENT 428.06 513.67 0.019 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F7 S2 APARTMENT 428.05 513.66 0.019 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F8 SW APARTMENT 981.64 1177.97 0.044 0.052 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F8 NW APARTMENT 982.64 1179.17 0.044 0.052 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F8 SE APARTMENT 981.43 1177.72 0.044 0.052 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F8 NE APARTMENT 982.43 1178.92 0.044 0.052 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F8 N1 APARTMENT 456.48 547.78 0.020 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F8 N2 APARTMENT 456.48 547.77 0.020 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F8 S1 APARTMENT 455.62 546.74 0.020 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F8 S2 APARTMENT 455.61 546.74 0.020 0.026 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F9 SW APARTMENT 1085.22 1302.26 0.048 0.058 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F9 NW APARTMENT 1084.51 1301.41 0.048 0.058 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F9 SE APARTMENT 1085.17 1302.21 0.048 0.058 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F9 NE APARTMENT 1084.47 1301.36 0.048 0.058 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F9 N1 APARTMENT 546.57 655.88 0.024 0.029 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F9 N2 APARTMENT 546.57 655.88 0.024 0.029 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F9 S1 APARTMENT 547.03 656.44 0.024 0.029 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
F9 S2 APARTMENT 547.03 656.44 0.024 0.029 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
T SW APARTMENT 1428.49 1714.19 0.064 0.076 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
T NW APARTMENT 1431.57 1717.89 0.064 0.076 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
T SE APARTMENT 1428.58 1714.29 0.064 0.076 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
T NE APARTMENT 1431.66 1717.99 0.064 0.076 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
T N1 APARTMENT 917.07 1100.48 0.041 0.049 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
T N2 APARTMENT 917.07 1100.48 0.041 0.049 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
T S1 APARTMENT 911.38 1093.66 0.041 0.049 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496
T S2 APARTMENT 911.39 1093.66 0.041 0.049 SAN FRANCISCO INTL AP ANN HTG 99.6% CONDNS DB 1/21 15:00:00 3.80 0.00496


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
AIRLOOP G SW 0.18 0.18 0.05 0.05
AIRLOOP G NW 0.15 0.15 0.05 0.05
AIRLOOP OFFICE 0.29 0.29 0.06 0.06
AIRLOOP G NE 0.10 0.10 0.05 0.05
AIRLOOP G N1 0.06 0.06 0.03 0.03
AIRLOOP G N2 0.06 0.06 0.03 0.03
AIRLOOP G S1 0.11 0.11 0.03 0.03
AIRLOOP G S2 0.12 0.12 0.03 0.03
AIRLOOP F2 SW 0.23 0.23 0.05 0.05
AIRLOOP F2 NW 0.19 0.19 0.05 0.05
AIRLOOP F2 SE 0.22 0.22 0.05 0.05
AIRLOOP F2 NE 0.14 0.14 0.05 0.05
AIRLOOP F2 N1 0.09 0.09 0.03 0.03
AIRLOOP F2 N2 0.09 0.09 0.03 0.03
AIRLOOP F2 S1 0.15 0.15 0.03 0.03
AIRLOOP F2 S2 0.16 0.16 0.03 0.03
AIRLOOP F3 SW 0.23 0.23 0.04 0.04
AIRLOOP F3 NW 0.19 0.19 0.04 0.04
AIRLOOP F3 SE 0.20 0.20 0.04 0.04
AIRLOOP F3 NE 0.14 0.14 0.04 0.04
AIRLOOP F3 N1 0.10 0.10 0.03 0.03
AIRLOOP F3 N2 0.10 0.10 0.03 0.03
AIRLOOP F3 S1 0.16 0.16 0.03 0.03
AIRLOOP F3 S2 0.16 0.16 0.03 0.03
AIRLOOP F4 SW 0.23 0.23 0.05 0.05
AIRLOOP F4 NW 0.19 0.19 0.05 0.05
AIRLOOP F4 SE 0.20 0.20 0.05 0.05
AIRLOOP F4 NE 0.14 0.14 0.05 0.05
AIRLOOP F4 N1 0.10 0.10 0.03 0.03
AIRLOOP F4 N2 0.10 0.10 0.03 0.03
AIRLOOP F4 S1 0.16 0.16 0.03 0.03
AIRLOOP F4 S2 0.16 0.16 0.03 0.03
AIRLOOP M SW 0.23 0.23 0.05 0.05
AIRLOOP M NW 0.19 0.19 0.05 0.05
AIRLOOP M SE 0.20 0.20 0.05 0.05
AIRLOOP M NE 0.15 0.15 0.05 0.05
AIRLOOP M N1 0.10 0.10 0.03 0.03
AIRLOOP M N2 0.10 0.10 0.03 0.03
AIRLOOP M S1 0.16 0.16 0.03 0.03
AIRLOOP M S2 0.16 0.16 0.03 0.03
AIRLOOP F6 SW 0.22 0.22 0.05 0.05
AIRLOOP F6 NW 0.19 0.19 0.05 0.05
AIRLOOP F6 SE 0.20 0.20 0.05 0.05
AIRLOOP F6 NE 0.14 0.14 0.05 0.05
AIRLOOP F6 N1 0.10 0.10 0.03 0.03
AIRLOOP F6 N2 0.10 0.10 0.03 0.03
AIRLOOP F6 S1 0.16 0.16 0.03 0.03
AIRLOOP F6 S2 0.16 0.16 0.03 0.03
AIRLOOP F7 SW 0.22 0.22 0.05 0.05
AIRLOOP F7 NW 0.19 0.19 0.05 0.05
AIRLOOP F7 SE 0.20 0.20 0.05 0.05
AIRLOOP F7 NE 0.14 0.14 0.05 0.05
AIRLOOP F7 N1 0.10 0.10 0.03 0.03
AIRLOOP F7 N2 0.10 0.10 0.03 0.03
AIRLOOP F7 S1 0.16 0.16 0.03 0.03
AIRLOOP F7 S2 0.16 0.16 0.03 0.03
AIRLOOP F8 SW 0.22 0.22 0.05 0.05
AIRLOOP F8 NW 0.19 0.19 0.05 0.05
AIRLOOP F8 SE 0.20 0.20 0.05 0.05
AIRLOOP F8 NE 0.14 0.14 0.05 0.05
AIRLOOP F8 N1 0.10 0.10 0.03 0.03
AIRLOOP F8 N2 0.10 0.10 0.03 0.03
AIRLOOP F8 S1 0.16 0.16 0.03 0.03
AIRLOOP F8 S2 0.16 0.16 0.03 0.03
AIRLOOP F9 SW 0.23 0.23 0.06 0.06
AIRLOOP F9 NW 0.19 0.19 0.06 0.06
AIRLOOP F9 SE 0.20 0.20 0.06 0.06
AIRLOOP F9 NE 0.14 0.14 0.06 0.06
AIRLOOP F9 N1 0.10 0.10 0.03 0.03
AIRLOOP F9 N2 0.10 0.10 0.03 0.03
AIRLOOP F9 S1 0.16 0.16 0.03 0.03
AIRLOOP F9 S2 0.16 0.16 0.03 0.03
AIRLOOP T SW 0.28 0.28 0.08 0.08
AIRLOOP T NW 0.24 0.24 0.08 0.08
AIRLOOP T SE 0.26 0.26 0.08 0.08
AIRLOOP T NE 0.18 0.18 0.08 0.08
AIRLOOP T N1 0.14 0.14 0.05 0.05
AIRLOOP T N2 0.14 0.14 0.05 0.05
AIRLOOP T S1 0.22 0.22 0.05 0.05
AIRLOOP T S2 0.22 0.22 0.05 0.05



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:07

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 709.50 7290.75 22.50
G NW APARTMENT 272.75 8211.50 19.50
OFFICE 1098.25 391.75 0.00
G NE APARTMENT 224.75 8285.75 19.25
G N1 APARTMENT 109.25 8527.25 31.00
G N2 APARTMENT 108.25 8529.25 30.75
G S1 APARTMENT 535.50 7530.00 40.75
G S2 APARTMENT 605.00 7382.50 43.50
F2 SW APARTMENT 1496.00 5655.25 17.25
F2 NW APARTMENT 369.25 7870.50 20.25
F2 SE APARTMENT 1912.50 5018.25 17.00
F2 NE APARTMENT 322.25 8013.50 20.50
F2 N1 APARTMENT 190.50 8306.75 36.00
F2 N2 APARTMENT 187.50 8316.25 35.25
F2 S1 APARTMENT 1532.75 5447.00 33.50
F2 S2 APARTMENT 1601.75 5331.00 32.00
F3 SW APARTMENT 1663.25 5419.75 15.25
F3 NW APARTMENT 344.50 7895.50 19.25
F3 SE APARTMENT 1676.75 5474.50 16.25
F3 NE APARTMENT 331.50 7984.00 19.50
F3 N1 APARTMENT 199.75 8228.75 37.00
F3 N2 APARTMENT 196.25 8239.50 36.75
F3 S1 APARTMENT 2004.50 4764.25 28.50
F3 S2 APARTMENT 2019.50 4741.25 28.50
F4 SW APARTMENT 1650.25 5465.25 14.25
F4 NW APARTMENT 330.25 7943.75 22.75
F4 SE APARTMENT 1590.50 5640.00 14.75
F4 NE APARTMENT 329.25 8007.50 23.50
F4 N1 APARTMENT 217.25 8197.50 46.50
F4 N2 APARTMENT 213.00 8208.75 46.00
F4 S1 APARTMENT 2160.00 4642.50 31.50
F4 S2 APARTMENT 2148.50 4656.75 31.50
M SW APARTMENT 1532.75 5658.00 13.50
M NW APARTMENT 305.75 7994.00 19.75
M SE APARTMENT 1484.50 5830.00 14.00
M NE APARTMENT 316.00 8048.50 21.75
M N1 APARTMENT 215.75 8201.75 43.25
M N2 APARTMENT 213.25 8211.00 42.75
M S1 APARTMENT 2105.50 4719.50 26.25
M S2 APARTMENT 2090.25 4730.25 26.00
F6 SW APARTMENT 1236.50 6150.00 12.75
F6 NW APARTMENT 235.50 8175.75 18.75
F6 SE APARTMENT 1208.75 6303.00 13.00
F6 NE APARTMENT 250.50 8189.75 19.75
F6 N1 APARTMENT 166.50 8339.00 38.75
F6 N2 APARTMENT 168.25 8343.75 39.00
F6 S1 APARTMENT 1724.50 5240.50 24.00
F6 S2 APARTMENT 1716.00 5258.75 24.00
F7 SW APARTMENT 1029.75 6514.50 12.50
F7 NW APARTMENT 200.00 8277.00 18.25
F7 SE APARTMENT 1033.00 6604.50 12.50
F7 NE APARTMENT 216.25 8272.75 17.50
F7 N1 APARTMENT 137.50 8414.25 37.00
F7 N2 APARTMENT 135.75 8419.50 36.75
F7 S1 APARTMENT 1436.00 5653.75 21.50
F7 S2 APARTMENT 1430.75 5670.75 21.00
F8 SW APARTMENT 884.50 6789.00 11.75
F8 NW APARTMENT 180.75 8327.50 17.25
F8 SE APARTMENT 915.00 6846.00 11.75
F8 NE APARTMENT 196.25 8329.00 17.00
F8 N1 APARTMENT 114.00 8461.75 34.00
F8 N2 APARTMENT 112.75 8469.00 33.50
F8 S1 APARTMENT 1219.00 6013.50 19.25
F8 S2 APARTMENT 1217.25 6024.75 19.50
F9 SW APARTMENT 761.25 7050.00 10.50
F9 NW APARTMENT 173.50 8359.25 17.00
F9 SE APARTMENT 785.50 7087.75 10.75
F9 NE APARTMENT 182.00 8361.75 17.00
F9 N1 APARTMENT 106.25 8479.25 31.25
F9 N2 APARTMENT 106.00 8482.25 31.25
F9 S1 APARTMENT 998.25 6388.00 18.50
F9 S2 APARTMENT 993.25 6395.75 18.50
T SW APARTMENT 1170.25 7023.00 10.25
T NW APARTMENT 422.25 8114.00 17.50
T SE APARTMENT 1235.25 6991.75 11.75
T NE APARTMENT 446.75 8027.00 21.75
T N1 APARTMENT 271.25 8290.50 25.00
T N2 APARTMENT 275.50 8287.00 25.25
T S1 APARTMENT 1206.50 6807.00 16.50
T S2 APARTMENT 1214.50 6808.00 16.50
G CORRIDOR 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00
Facility 3248.50 8606.50 72.75
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 1.50 0.00 1.50 0.00
G NW APARTMENT 1.00 0.25 1.00 0.25
OFFICE 3.00 0.00 0.00 0.00
G NE APARTMENT 9.25 0.00 9.25 0.00
G N1 APARTMENT 13.00 2.50 13.00 2.50
G N2 APARTMENT 16.50 2.50 16.50 2.50
G S1 APARTMENT 3.50 1.50 3.50 1.50
G S2 APARTMENT 1.25 1.00 1.25 1.00
F2 SW APARTMENT 0.00 0.00 0.00 0.00
F2 NW APARTMENT 0.75 0.00 0.75 0.00
F2 SE APARTMENT 0.25 0.00 0.25 0.00
F2 NE APARTMENT 6.50 0.25 6.50 0.25
F2 N1 APARTMENT 3.25 1.75 3.25 1.75
F2 N2 APARTMENT 3.25 1.75 3.25 1.75
F2 S1 APARTMENT 0.00 0.75 0.00 0.75
F2 S2 APARTMENT 0.00 0.75 0.00 0.75
F3 SW APARTMENT 0.00 0.00 0.00 0.00
F3 NW APARTMENT 2.00 0.50 2.00 0.50
F3 SE APARTMENT 0.25 0.25 0.25 0.25
F3 NE APARTMENT 3.75 0.50 3.75 0.50
F3 N1 APARTMENT 2.50 1.75 2.50 1.75
F3 N2 APARTMENT 1.75 1.75 1.75 1.75
F3 S1 APARTMENT 0.00 2.50 0.00 2.50
F3 S2 APARTMENT 0.00 2.50 0.00 2.50
F4 SW APARTMENT 0.25 0.00 0.25 0.00
F4 NW APARTMENT 1.75 0.50 1.75 0.50
F4 SE APARTMENT 0.00 0.75 0.00 0.75
F4 NE APARTMENT 1.75 0.75 1.75 0.75
F4 N1 APARTMENT 1.50 1.75 1.50 1.75
F4 N2 APARTMENT 1.25 1.75 1.25 1.75
F4 S1 APARTMENT 0.00 2.75 0.00 2.75
F4 S2 APARTMENT 0.00 2.75 0.00 2.75
M SW APARTMENT 0.25 0.00 0.25 0.00
M NW APARTMENT 0.50 0.50 0.50 0.50
M SE APARTMENT 0.00 0.75 0.00 0.75
M NE APARTMENT 1.50 1.00 1.50 1.00
M N1 APARTMENT 2.50 1.75 2.50 1.75
M N2 APARTMENT 1.00 1.75 1.00 1.75
M S1 APARTMENT 0.00 2.75 0.00 2.75
M S2 APARTMENT 0.00 2.75 0.00 2.75
F6 SW APARTMENT 0.00 0.00 0.00 0.00
F6 NW APARTMENT 0.00 0.50 0.00 0.50
F6 SE APARTMENT 0.00 0.75 0.00 0.75
F6 NE APARTMENT 2.50 1.50 2.50 1.50
F6 N1 APARTMENT 3.50 1.75 3.50 1.75
F6 N2 APARTMENT 4.50 1.75 4.50 1.75
F6 S1 APARTMENT 0.00 2.75 0.00 2.75
F6 S2 APARTMENT 0.00 2.75 0.00 2.75
F7 SW APARTMENT 0.00 0.00 0.00 0.00
F7 NW APARTMENT 1.25 0.50 1.25 0.50
F7 SE APARTMENT 0.25 0.50 0.25 0.50
F7 NE APARTMENT 1.75 1.50 1.75 1.50
F7 N1 APARTMENT 4.25 1.50 4.25 1.50
F7 N2 APARTMENT 4.25 1.50 4.25 1.50
F7 S1 APARTMENT 0.25 2.00 0.25 2.00
F7 S2 APARTMENT 0.25 2.00 0.25 2.00
F8 SW APARTMENT 0.00 0.00 0.00 0.00
F8 NW APARTMENT 1.75 0.50 1.75 0.50
F8 SE APARTMENT 0.00 0.25 0.00 0.25
F8 NE APARTMENT 3.25 1.50 3.25 1.50
F8 N1 APARTMENT 5.50 1.50 5.50 1.50
F8 N2 APARTMENT 4.50 1.50 4.50 1.50
F8 S1 APARTMENT 0.00 1.75 0.00 1.75
F8 S2 APARTMENT 0.25 1.75 0.25 1.75
F9 SW APARTMENT 0.25 0.00 0.25 0.00
F9 NW APARTMENT 0.50 0.50 0.50 0.50
F9 SE APARTMENT 0.00 0.00 0.00 0.00
F9 NE APARTMENT 2.25 2.00 2.25 2.00
F9 N1 APARTMENT 7.25 1.50 7.25 1.50
F9 N2 APARTMENT 6.75 1.50 6.75 1.50
F9 S1 APARTMENT 0.00 0.25 0.00 0.25
F9 S2 APARTMENT 0.25 0.25 0.25 0.25
T SW APARTMENT 0.00 0.00 0.00 0.00
T NW APARTMENT 0.00 1.00 0.00 1.00
T SE APARTMENT 0.00 0.25 0.00 0.25
T NE APARTMENT 0.00 7.25 0.00 7.25
T N1 APARTMENT 2.75 6.25 2.75 6.25
T N2 APARTMENT 2.75 6.00 2.75 6.00
T S1 APARTMENT 0.50 1.75 0.50 1.75
T S2 APARTMENT 0.50 1.75 0.50 1.75
G CORRIDOR 0.00 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
Facility 121.25 12.75 119.00 12.75
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:07

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.354 0.208 0.000 0.474
G NW APARTMENT 1.71 2.50 268.96 0.353 0.208 0.000 0.455
OFFICE 0.94 1.00 268.96 0.521 0.222 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.353 0.207 0.000 0.454
G N1 APARTMENT 1.71 2.50 268.96 0.353 0.125 0.000 0.444
G N2 APARTMENT 1.71 2.50 268.97 0.353 0.125 0.000 0.444
G S1 APARTMENT 1.71 2.50 268.96 0.354 0.125 0.000 0.466
G S2 APARTMENT 1.71 2.50 268.97 0.354 0.125 0.000 0.469
F2 SW APARTMENT 1.71 2.50 268.96 0.354 0.299 0.000 0.560
F2 NW APARTMENT 1.71 2.50 268.96 0.353 0.298 0.000 0.539
F2 SE APARTMENT 1.71 2.50 268.96 0.355 0.299 0.000 0.566
F2 NE APARTMENT 1.71 2.50 268.96 0.353 0.298 0.000 0.539
F2 N1 APARTMENT 1.71 2.50 268.96 0.353 0.180 0.000 0.530
F2 N2 APARTMENT 1.71 2.50 268.97 0.353 0.180 0.000 0.529
F2 S1 APARTMENT 1.71 2.50 268.96 0.355 0.180 0.000 0.555
F2 S2 APARTMENT 1.71 2.50 268.97 0.355 0.180 0.000 0.556
F3 SW APARTMENT 1.71 2.50 268.96 0.354 0.354 0.000 0.611
F3 NW APARTMENT 1.71 2.50 268.96 0.353 0.353 0.000 0.591
F3 SE APARTMENT 1.71 2.50 268.96 0.354 0.354 0.000 0.613
F3 NE APARTMENT 1.71 2.50 268.96 0.353 0.353 0.000 0.591
F3 N1 APARTMENT 1.71 2.50 268.96 0.354 0.213 0.000 0.583
F3 N2 APARTMENT 1.71 2.50 268.97 0.354 0.213 0.000 0.583
F3 S1 APARTMENT 1.71 2.50 268.96 0.355 0.214 0.000 0.607
F3 S2 APARTMENT 1.71 2.50 268.97 0.355 0.214 0.000 0.608
F4 SW APARTMENT 1.71 2.50 268.96 0.354 0.396 0.000 0.614
F4 NW APARTMENT 1.71 2.50 268.96 0.353 0.395 0.000 0.596
F4 SE APARTMENT 1.71 2.50 268.96 0.354 0.395 0.000 0.615
F4 NE APARTMENT 1.71 2.50 268.96 0.353 0.395 0.000 0.597
F4 N1 APARTMENT 1.71 2.50 268.96 0.354 0.238 0.000 0.590
F4 N2 APARTMENT 1.71 2.50 268.97 0.354 0.238 0.000 0.590
F4 S1 APARTMENT 1.71 2.50 268.96 0.355 0.239 0.000 0.611
F4 S2 APARTMENT 1.71 2.50 268.97 0.355 0.239 0.000 0.611
M SW APARTMENT 1.71 2.50 268.96 0.354 0.430 0.000 0.646
M NW APARTMENT 1.71 2.50 268.96 0.353 0.429 0.000 0.629
M SE APARTMENT 1.71 2.50 268.96 0.354 0.430 0.000 0.647
M NE APARTMENT 1.71 2.50 268.96 0.353 0.429 0.000 0.629
M N1 APARTMENT 1.71 2.50 268.96 0.354 0.259 0.000 0.624
M N2 APARTMENT 1.71 2.50 268.97 0.354 0.259 0.000 0.624
M S1 APARTMENT 1.71 2.50 268.96 0.355 0.259 0.000 0.643
M S2 APARTMENT 1.71 2.50 268.97 0.355 0.259 0.000 0.644
F6 SW APARTMENT 1.71 2.50 268.96 0.354 0.459 0.000 0.671
F6 NW APARTMENT 1.71 2.50 268.96 0.353 0.458 0.000 0.655
F6 SE APARTMENT 1.71 2.50 268.96 0.354 0.459 0.000 0.672
F6 NE APARTMENT 1.71 2.50 268.96 0.353 0.458 0.000 0.656
F6 N1 APARTMENT 1.71 2.50 268.96 0.353 0.276 0.000 0.650
F6 N2 APARTMENT 1.71 2.50 268.97 0.353 0.276 0.000 0.650
F6 S1 APARTMENT 1.71 2.50 268.96 0.354 0.277 0.000 0.669
F6 S2 APARTMENT 1.71 2.50 268.97 0.354 0.277 0.000 0.669
F7 SW APARTMENT 1.71 2.50 268.96 0.354 0.485 0.000 0.692
F7 NW APARTMENT 1.71 2.50 268.96 0.353 0.484 0.000 0.677
F7 SE APARTMENT 1.71 2.50 268.96 0.354 0.485 0.000 0.694
F7 NE APARTMENT 1.71 2.50 268.96 0.353 0.484 0.000 0.678
F7 N1 APARTMENT 1.71 2.50 268.96 0.353 0.292 0.000 0.673
F7 N2 APARTMENT 1.71 2.50 268.97 0.353 0.292 0.000 0.673
F7 S1 APARTMENT 1.71 2.50 268.96 0.354 0.293 0.000 0.691
F7 S2 APARTMENT 1.71 2.50 268.97 0.354 0.293 0.000 0.691
F8 SW APARTMENT 1.71 2.50 268.96 0.354 0.508 0.000 0.715
F8 NW APARTMENT 1.71 2.50 268.96 0.353 0.507 0.000 0.700
F8 SE APARTMENT 1.71 2.50 268.96 0.354 0.508 0.000 0.716
F8 NE APARTMENT 1.71 2.50 268.96 0.353 0.507 0.000 0.701
F8 N1 APARTMENT 1.71 2.50 268.96 0.353 0.306 0.000 0.696
F8 N2 APARTMENT 1.71 2.50 268.97 0.353 0.306 0.000 0.696
F8 S1 APARTMENT 1.71 2.50 268.96 0.354 0.307 0.000 0.713
F8 S2 APARTMENT 1.71 2.50 268.97 0.354 0.307 0.000 0.713
F9 SW APARTMENT 1.71 2.50 268.96 0.354 0.529 0.000 0.734
F9 NW APARTMENT 1.71 2.50 268.96 0.353 0.529 0.000 0.721
F9 SE APARTMENT 1.71 2.50 268.96 0.354 0.529 0.000 0.736
F9 NE APARTMENT 1.71 2.50 268.96 0.353 0.528 0.000 0.722
F9 N1 APARTMENT 1.71 2.50 268.96 0.353 0.319 0.000 0.717
F9 N2 APARTMENT 1.71 2.50 268.97 0.353 0.319 0.000 0.717
F9 S1 APARTMENT 1.71 2.50 268.96 0.354 0.320 0.000 0.733
F9 S2 APARTMENT 1.71 2.50 268.97 0.354 0.320 0.000 0.733
T SW APARTMENT 1.71 2.50 268.96 0.353 0.549 0.000 0.750
T NW APARTMENT 1.71 2.50 268.96 0.353 0.548 0.000 0.738
T SE APARTMENT 1.71 2.50 268.96 0.353 0.549 0.000 0.752
T NE APARTMENT 1.71 2.50 268.96 0.353 0.548 0.000 0.740
T N1 APARTMENT 1.71 2.50 268.96 0.353 0.331 0.000 0.734
T N2 APARTMENT 1.71 2.50 268.97 0.353 0.331 0.000 0.734
T S1 APARTMENT 1.71 2.50 268.96 0.354 0.331 0.000 0.748
T S2 APARTMENT 1.71 2.50 268.97 0.354 0.331 0.000 0.748
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
OFFICE 0.94 1.00 268.96 0.504 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
F2 SW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F2 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F2 SE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F2 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F2 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F2 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F2 S1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F2 S2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
F3 SW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F3 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F3 SE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F3 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F3 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F3 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F3 S1 APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F3 S2 APARTMENT 1.71 2.50 268.97 0.345 0.000 0.000 0.000
F4 SW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F4 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F4 SE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F4 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F4 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F4 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F4 S1 APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F4 S2 APARTMENT 1.71 2.50 268.97 0.345 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 0.345 0.000 0.000 0.000
F6 SW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F6 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F6 SE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F6 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F6 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F6 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F6 S1 APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F6 S2 APARTMENT 1.71 2.50 268.97 0.345 0.000 0.000 0.000
F7 SW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F7 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F7 SE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F7 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F7 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F7 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F7 S1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F7 S2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
F8 SW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F8 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F8 SE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F8 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F8 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F8 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F8 S1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F8 S2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
F9 SW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F9 NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F9 SE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F9 NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F9 N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
F9 N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
F9 S1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F9 S2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.96 0.343 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:07

Surfaces by Class

Total Outdoors
Wall 420 140
Floor 90 9
Roof 90 9
Internal Mass 80 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 140 140
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 80
Conditioned Zones 80
Unconditioned Zones 10
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 4156
Defaulted Fields 814
Fields with Defaults 11184
Autosized Fields 1293
Autosizable Fields 1630
Autocalculated Fields 907
Autocalculatable Fields 1710



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2015-09-09 19:12:07

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 2247.28 49729.53 02-JUN-05:00 135664.16 30-JUN-16:45
Electricity:Building 1433.88 25760.85 01-JAN-03:15 70162.48 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity 296.56 6715.87 01-JAN-00:15 14401.37 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 242.55 5824.91 01-JAN-00:15 11484.27 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:OFFICE 39.38 663.42 01-JAN-00:15 2934.49 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 29.88 469.18 01-JAN-00:15 2345.88 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:G CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F2 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F2 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F3 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F3 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F4 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F4 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:M SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M CORRIDOR 32.88 1042.61 01-JAN-00:15 1042.61 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 32.88 1042.61 01-JAN-00:15 1042.61 01-JAN-00:15
Electricity:Zone:F6 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F6 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F7 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F7 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F8 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F8 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F9 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F9 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:T SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T CORRIDOR 179.47 1701.70 01-JAN-00:15 10868.20 01-JAN-07:15
InteriorLights:Electricity:Zone:T CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 54.01 890.97 01-JAN-00:15 2917.11 01-JAN-19:15
InteriorEquipment:Electricity 1137.32 19044.98 01-JAN-03:15 57142.09 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 1137.32 19044.98 01-JAN-03:15 57142.09 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 9.50 194.24 01-JAN-00:15 588.62 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T CORRIDOR 163.03 1180.40 01-JAN-00:15 10346.90 01-JAN-07:15
Fans:Electricity 473.52 15015.24 06-JAN-13:15 15015.24 01-JAN-06:15
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Electricity:HVAC 610.47 15676.48 13-APR-02:45 64342.56 30-JUN-16:45
ElectricityProduced:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityProduced:HVAC 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricityProduced 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 2247.28 49729.53 02-JUN-05:00 135664.16 30-JUN-16:45
ElectricityPurchased:Plant 2247.28 49729.53 02-JUN-05:00 135664.16 30-JUN-16:45
Cogeneration:ElectricityPurchased 2247.28 49729.53 02-JUN-05:00 135664.16 30-JUN-16:45
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 2247.28 49729.53 02-JUN-05:00 135664.16 30-JUN-16:45
ElectricityNet:Plant 2247.28 49729.53 02-JUN-05:00 135664.16 30-JUN-16:45
Cogeneration:ElectricityNet 2247.28 49729.53 02-JUN-05:00 135664.16 30-JUN-16:45
ExteriorLights:Electricity 162.73 0.00 01-JAN-07:30 10364.00 01-JAN-00:15
General:ExteriorLights:Electricity 162.73 0.00 01-JAN-07:30 10364.00 01-JAN-00:15
General:Fans:Electricity 473.52 15015.24 06-JAN-13:15 15015.24 01-JAN-06:15
Cooling:Electricity 45.38 0.00 01-JAN-00:15 47398.40 03-AUG-14:30
Heating:Electricity 55.40 0.00 02-JAN-13:00 46994.03 30-APR-15:30
Electricity:Plant 40.19 36.93 16-JAN-11:00 2960.95 30-JUN-14:00
HeatRejection:Electricity 1.75 0.00 01-JAN-00:15 1628.64 30-JUN-14:00
Boiler Parasitic:Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Pumps:Electricity 38.45 36.93 16-JAN-11:00 1332.31 01-JAN-00:15
WIRED_LTG_ELECTRICITY 0.44 0.00 01-JAN-00:15 21.60 01-JAN-19:30
WIRED_INT_EQUIP 979.40 1018.50 01-JAN-00:15 10185.00 01-JAN-07:15


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 1228.31 2357.00 01-JAN-00:15 187090.97 17-MAY-20:00
Gas:Plant 1228.31 2357.00 01-JAN-00:15 187090.97 17-MAY-20:00
WaterSystems:Gas 1093.79 2357.00 01-JAN-00:15 77425.82 09-FEB-08:00
Water Heater:WaterSystems:Gas 1093.79 2357.00 01-JAN-00:15 77425.82 09-FEB-08:00
Heating:Gas 134.51 0.00 01-JAN-00:15 120179.38 17-MAY-20:15
Boiler:Heating:Gas 134.51 0.00 01-JAN-00:15 120179.38 17-MAY-20:15


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
PlantLoopCoolingDemand:Facility 182.41 0.00 01-JAN-00:15 216413.43 03-AUG-14:30
PlantLoopCoolingDemand:HVAC 182.41 0.00 01-JAN-00:15 216413.43 03-AUG-14:30
CoolingCoils:PlantLoopCoolingDemand 182.41 0.00 01-JAN-00:15 216413.43 03-AUG-14:30


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 4958.51 0.00 01-JAN-02:15 0.00 30-JUN-17:15
Water:Plant 4958.51 0.00 01-JAN-02:15 0.00 30-JUN-17:15
WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
MainsWater:Facility 4958.51 0.00 01-JAN-02:15 0.00 30-JUN-17:15
MainsWater:Plant 4958.51 0.00 01-JAN-02:15 0.00 30-JUN-17:15
WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
sub cat:WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
sub cat:WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
HeatRejection:Water 179.99 0.00 01-JAN-00:15 0.00 30-JUN-14:00
HeatRejection:MainsWater 179.99 0.00 01-JAN-00:15 0.00 30-JUN-14:00


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 1000.39 478.53 10-AUG-01:15 131688.36 17-MAY-20:00
PlantLoopHeatingDemand:Plant 850.24 478.53 10-AUG-01:15 54003.88 03-FEB-08:00
WaterSystems:PlantLoopHeatingDemand 850.24 478.53 10-AUG-01:15 54003.88 03-FEB-08:00
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 1810.42 4158.40 24-MAY-01:15 397462.46 11-SEP-18:15
EnergyTransfer:Building 523.76 2744.46 16-OCT-19:45 141651.97 30-JUN-16:45
EnergyTransfer:Zone:G SW APARTMENT 4.56 0.00 14-NOV-14:00 1965.53 15-SEP-16:15
Heating:EnergyTransfer 169.70 0.00 01-JAN-12:45 137929.28 11-SEP-18:15
Heating:EnergyTransfer:Zone:G SW APARTMENT 1.07 0.00 01-JAN-00:15 1141.93 16-APR-13:00
Cooling:EnergyTransfer 354.06 0.00 04-MAR-15:30 141651.97 30-JUN-16:45
Cooling:EnergyTransfer:Zone:G SW APARTMENT 3.49 0.00 01-JAN-02:00 1965.53 15-SEP-16:15
EnergyTransfer:Zone:G NW APARTMENT 4.68 0.01 05-JUL-15:00 1662.36 30-JUN-17:30
Heating:EnergyTransfer:Zone:G NW APARTMENT 2.61 0.00 01-JAN-12:45 1447.63 12-MAR-08:00
Cooling:EnergyTransfer:Zone:G NW APARTMENT 2.07 0.00 01-JAN-00:15 1662.36 30-JUN-17:30
EnergyTransfer:Zone:OFFICE 13.92 0.01 24-JUN-17:00 3087.16 15-SEP-14:00
Heating:EnergyTransfer:Zone:OFFICE 0.32 0.00 01-JAN-00:15 806.70 22-DEC-05:00
Cooling:EnergyTransfer:Zone:OFFICE 13.60 0.00 01-JAN-02:30 3087.16 15-SEP-14:00
EnergyTransfer:Zone:G NE APARTMENT 5.13 0.01 19-FEB-15:00 1479.52 22-APR-15:00
Heating:EnergyTransfer:Zone:G NE APARTMENT 2.60 0.00 01-JAN-08:30 1479.52 22-APR-15:00
Cooling:EnergyTransfer:Zone:G NE APARTMENT 2.53 0.00 01-JAN-00:15 1153.88 30-JUN-17:45
EnergyTransfer:Zone:G N1 APARTMENT 5.23 0.01 19-JAN-01:15 1392.18 22-APR-15:00
Heating:EnergyTransfer:Zone:G N1 APARTMENT 1.58 0.00 01-JAN-06:30 1392.18 22-APR-15:00
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 3.66 0.00 01-JAN-00:15 738.81 30-JUN-19:00
EnergyTransfer:Zone:G N2 APARTMENT 5.25 0.03 04-NOV-24:00 1397.37 22-APR-15:00
Heating:EnergyTransfer:Zone:G N2 APARTMENT 1.59 0.00 01-JAN-06:30 1397.37 22-APR-15:00
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 3.66 0.00 01-JAN-00:15 724.49 30-JUN-19:00
EnergyTransfer:Zone:G S1 APARTMENT 5.62 0.01 04-MAR-15:15 1295.77 31-AUG-13:30
Heating:EnergyTransfer:Zone:G S1 APARTMENT 0.40 0.00 01-JAN-00:15 1012.60 16-APR-13:00
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 5.23 0.00 07-JAN-11:30 1295.77 31-AUG-13:30
EnergyTransfer:Zone:G S2 APARTMENT 5.60 0.02 09-OCT-13:30 1359.00 31-AUG-13:30
Heating:EnergyTransfer:Zone:G S2 APARTMENT 0.33 0.00 01-JAN-00:15 992.76 16-APR-13:00
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 5.27 0.00 08-JAN-01:45 1359.00 31-AUG-13:30
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F2 SW APARTMENT 5.46 0.01 24-MAY-00:15 2522.94 30-JUN-16:45
Heating:EnergyTransfer:Zone:F2 SW APARTMENT 0.78 0.00 01-JAN-00:15 1149.09 17-MAY-20:00
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT 4.68 0.00 03-JAN-04:00 2522.94 30-JUN-16:45
EnergyTransfer:Zone:F2 NW APARTMENT 4.09 0.03 29-DEC-05:45 2148.43 30-JUN-17:30
Heating:EnergyTransfer:Zone:F2 NW APARTMENT 1.77 0.00 01-JAN-01:00 1679.03 12-MAR-08:00
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT 2.32 0.00 01-JAN-00:15 2148.43 30-JUN-17:30
EnergyTransfer:Zone:F2 SE APARTMENT 6.37 0.01 29-SEP-01:00 2430.79 16-SEP-13:15
Heating:EnergyTransfer:Zone:F2 SE APARTMENT 0.61 0.00 01-JAN-00:15 908.40 22-DEC-05:00
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT 5.76 0.00 03-JAN-04:00 2430.79 16-SEP-13:15
EnergyTransfer:Zone:F2 NE APARTMENT 4.71 0.01 28-SEP-08:00 1754.45 22-APR-15:00
Heating:EnergyTransfer:Zone:F2 NE APARTMENT 1.67 0.00 01-JAN-01:00 1754.45 22-APR-15:00
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT 3.04 0.00 01-JAN-00:15 1580.23 30-JUN-17:30
EnergyTransfer:Zone:F2 N1 APARTMENT 5.53 0.01 25-FEB-04:30 1594.35 22-APR-15:00
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT 0.86 0.00 01-JAN-00:15 1594.35 22-APR-15:00
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT 4.67 0.00 01-JAN-04:30 1069.29 30-JUN-19:00
EnergyTransfer:Zone:F2 N2 APARTMENT 5.54 0.00 21-OCT-14:00 1600.43 22-APR-15:00
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT 0.87 0.00 01-JAN-00:15 1600.43 22-APR-15:00
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT 4.67 0.00 01-JAN-04:30 1056.57 30-JUN-19:00
EnergyTransfer:Zone:F2 S1 APARTMENT 6.79 0.01 27-MAY-10:15 1758.17 16-SEP-15:45
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT 0.28 0.00 01-JAN-00:15 1035.00 21-APR-12:00
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT 6.51 0.00 19-JAN-12:45 1758.17 16-SEP-15:45
EnergyTransfer:Zone:F2 S2 APARTMENT 6.85 0.00 15-APR-12:45 1762.85 16-SEP-15:45
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT 0.27 0.00 01-JAN-00:15 1004.50 21-APR-12:00
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT 6.58 0.00 19-JAN-12:45 1762.85 16-SEP-15:45
EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F3 SW APARTMENT 5.92 0.00 08-OCT-02:00 2551.10 30-JUN-16:45
Heating:EnergyTransfer:Zone:F3 SW APARTMENT 0.87 0.00 01-JAN-00:15 1366.54 17-MAY-20:00
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT 5.05 0.00 03-JAN-04:00 2551.10 30-JUN-16:45
EnergyTransfer:Zone:F3 NW APARTMENT 4.30 0.01 03-JAN-23:45 2178.02 30-JUN-17:30
Heating:EnergyTransfer:Zone:F3 NW APARTMENT 1.89 0.00 01-JAN-00:30 1889.12 21-APR-12:00
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT 2.41 0.00 01-JAN-00:15 2178.02 30-JUN-17:30
EnergyTransfer:Zone:F3 SE APARTMENT 6.47 0.03 08-OCT-00:15 2302.91 16-SEP-14:00
Heating:EnergyTransfer:Zone:F3 SE APARTMENT 0.73 0.00 01-JAN-00:15 1403.58 21-JUN-15:00
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT 5.74 0.00 03-JAN-13:00 2302.91 16-SEP-14:00
EnergyTransfer:Zone:F3 NE APARTMENT 5.00 0.00 08-AUG-09:45 2059.20 22-APR-15:00
Heating:EnergyTransfer:Zone:F3 NE APARTMENT 1.84 0.00 01-JAN-00:30 2059.20 22-APR-15:00
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT 3.16 0.00 01-JAN-00:15 1619.12 30-JUN-17:30
EnergyTransfer:Zone:F3 N1 APARTMENT 5.87 0.00 04-SEP-09:15 1823.63 22-APR-15:00
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT 0.97 0.00 01-JAN-00:15 1823.63 22-APR-15:00
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT 4.90 0.00 01-JAN-05:00 1120.95 30-JUN-17:45
EnergyTransfer:Zone:F3 N2 APARTMENT 5.88 0.00 09-AUG-09:45 1830.12 22-APR-15:00
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT 0.98 0.00 01-JAN-00:15 1830.12 22-APR-15:00
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT 4.90 0.00 01-JAN-05:00 1108.23 30-JUN-17:45
EnergyTransfer:Zone:F3 S1 APARTMENT 7.61 0.02 04-MAY-11:30 1830.09 16-SEP-15:45
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT 0.37 0.00 01-JAN-00:15 1252.58 21-JUN-15:00
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT 7.24 0.00 19-JAN-12:45 1830.09 16-SEP-15:45
EnergyTransfer:Zone:F3 S2 APARTMENT 7.63 0.00 06-AUG-09:45 1837.32 16-SEP-15:45
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT 0.36 0.00 01-JAN-00:15 1252.43 21-JUN-15:00
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT 7.26 0.00 19-JAN-12:45 1837.32 16-SEP-15:45
EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F4 SW APARTMENT 5.98 0.00 15-FEB-11:30 2571.18 15-SEP-16:15
Heating:EnergyTransfer:Zone:F4 SW APARTMENT 0.96 0.00 01-JAN-00:15 1513.05 17-MAY-20:00
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT 5.02 0.00 03-JAN-04:00 2571.18 15-SEP-16:15
EnergyTransfer:Zone:F4 NW APARTMENT 4.42 0.05 17-OCT-01:00 2181.95 30-JUN-17:15
Heating:EnergyTransfer:Zone:F4 NW APARTMENT 2.06 0.00 01-JAN-00:30 2010.73 03-OCT-10:00
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT 2.36 0.00 01-JAN-00:15 2181.95 30-JUN-17:15
EnergyTransfer:Zone:F4 SE APARTMENT 6.46 0.02 14-MAY-06:30 2293.79 16-SEP-14:00
Heating:EnergyTransfer:Zone:F4 SE APARTMENT 0.88 0.00 01-JAN-00:15 1571.03 21-JUN-14:45
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT 5.57 0.00 03-JAN-13:15 2293.79 16-SEP-14:00
EnergyTransfer:Zone:F4 NE APARTMENT 5.14 0.00 20-AUG-09:30 2123.05 22-APR-14:45
Heating:EnergyTransfer:Zone:F4 NE APARTMENT 2.03 0.00 01-JAN-00:15 2123.05 22-APR-14:45
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT 3.12 0.00 01-JAN-01:45 1629.90 30-JUN-17:30
EnergyTransfer:Zone:F4 N1 APARTMENT 5.95 0.02 22-AUG-11:15 1929.14 30-APR-15:45
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT 1.02 0.00 01-JAN-00:15 1929.14 30-APR-15:45
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT 4.93 0.00 01-JAN-05:00 1138.22 30-JUN-17:45
EnergyTransfer:Zone:F4 N2 APARTMENT 5.97 0.01 27-MAY-13:00 1919.94 30-APR-15:45
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT 1.03 0.00 01-JAN-00:15 1919.94 30-APR-15:45
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT 4.94 0.00 01-JAN-05:00 1125.70 30-JUN-17:45
EnergyTransfer:Zone:F4 S1 APARTMENT 7.90 0.00 15-MAY-07:45 1874.84 19-NOV-14:00
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT 0.44 0.00 01-JAN-00:15 1369.43 21-JUN-14:45
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT 7.46 0.00 19-JAN-12:45 1874.84 19-NOV-14:00
EnergyTransfer:Zone:F4 S2 APARTMENT 7.89 0.00 27-SEP-11:30 1877.11 19-NOV-14:00
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT 0.44 0.00 01-JAN-00:15 1374.03 21-JUN-14:45
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT 7.45 0.00 19-JAN-12:45 1877.11 19-NOV-14:00
EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M SW APARTMENT 5.97 0.00 04-NOV-14:45 2589.37 15-SEP-16:15
Heating:EnergyTransfer:Zone:M SW APARTMENT 1.17 0.00 01-JAN-00:15 1693.11 17-MAY-20:00
Cooling:EnergyTransfer:Zone:M SW APARTMENT 4.80 0.00 03-JAN-03:45 2589.37 15-SEP-16:15
EnergyTransfer:Zone:M NW APARTMENT 4.67 0.02 28-FEB-15:15 2235.88 03-OCT-10:00
Heating:EnergyTransfer:Zone:M NW APARTMENT 2.41 0.00 01-JAN-00:15 2235.88 03-OCT-10:00
Cooling:EnergyTransfer:Zone:M NW APARTMENT 2.26 0.00 01-JAN-01:45 2203.50 30-JUN-17:15
EnergyTransfer:Zone:M SE APARTMENT 6.43 0.02 21-APR-11:45 2320.78 16-SEP-14:00
Heating:EnergyTransfer:Zone:M SE APARTMENT 1.11 0.00 01-JAN-00:15 1793.70 21-JUN-14:45
Cooling:EnergyTransfer:Zone:M SE APARTMENT 5.32 0.00 03-JAN-13:15 2320.78 16-SEP-14:00
EnergyTransfer:Zone:M NE APARTMENT 5.41 0.01 13-MAR-19:45 2357.83 22-APR-14:45
Heating:EnergyTransfer:Zone:M NE APARTMENT 2.39 0.00 01-JAN-00:30 2357.83 22-APR-14:45
Cooling:EnergyTransfer:Zone:M NE APARTMENT 3.02 0.00 01-JAN-00:15 1654.62 09-AUG-15:30
EnergyTransfer:Zone:M N1 APARTMENT 6.12 0.01 27-JUN-11:30 2136.64 30-APR-15:45
Heating:EnergyTransfer:Zone:M N1 APARTMENT 1.26 0.00 01-JAN-00:15 2136.64 30-APR-15:45
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 4.87 0.00 03-JAN-05:00 1168.69 30-JUN-17:45
EnergyTransfer:Zone:M N2 APARTMENT 6.14 0.00 07-AUG-10:15 2127.37 30-APR-15:45
Heating:EnergyTransfer:Zone:M N2 APARTMENT 1.27 0.00 01-JAN-00:15 2127.37 30-APR-15:45
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 4.88 0.00 03-JAN-05:00 1156.36 30-JUN-17:45
EnergyTransfer:Zone:M S1 APARTMENT 7.94 0.05 09-SEP-08:45 1917.38 19-NOV-14:00
Heating:EnergyTransfer:Zone:M S1 APARTMENT 0.59 0.00 01-JAN-00:15 1578.64 21-JUN-14:45
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 7.35 0.00 19-JAN-12:45 1917.38 19-NOV-14:00
EnergyTransfer:Zone:M S2 APARTMENT 7.92 0.03 13-SEP-11:15 1918.86 19-NOV-14:00
Heating:EnergyTransfer:Zone:M S2 APARTMENT 0.59 0.00 01-JAN-00:15 1583.81 21-JUN-14:45
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 7.33 0.00 19-JAN-12:45 1918.86 19-NOV-14:00
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F6 SW APARTMENT 5.80 0.01 21-APR-10:45 2544.98 30-JUN-16:45
Heating:EnergyTransfer:Zone:F6 SW APARTMENT 1.52 0.00 01-JAN-00:15 1922.76 17-MAY-20:00
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT 4.28 0.00 03-JAN-03:45 2544.98 30-JUN-16:45
EnergyTransfer:Zone:F6 NW APARTMENT 5.22 0.01 08-OCT-02:30 2501.03 03-OCT-10:00
Heating:EnergyTransfer:Zone:F6 NW APARTMENT 3.19 0.00 01-JAN-00:30 2501.03 03-OCT-10:00
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT 2.03 0.00 01-JAN-00:15 2161.71 30-JUN-17:15
EnergyTransfer:Zone:F6 SE APARTMENT 6.27 0.00 24-MAY-13:15 2287.29 16-SEP-14:00
Heating:EnergyTransfer:Zone:F6 SE APARTMENT 1.49 0.00 01-JAN-00:15 2035.56 21-JUN-14:45
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT 4.78 0.00 03-JAN-13:15 2287.29 16-SEP-14:00
EnergyTransfer:Zone:F6 NE APARTMENT 5.94 0.01 08-AUG-09:15 2634.89 22-APR-14:45
Heating:EnergyTransfer:Zone:F6 NE APARTMENT 3.22 0.00 01-JAN-00:45 2634.89 22-APR-14:45
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT 2.72 0.00 01-JAN-00:15 1621.66 09-AUG-15:30
EnergyTransfer:Zone:F6 N1 APARTMENT 6.34 0.01 08-JUL-18:15 2384.18 30-APR-15:45
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT 1.75 0.00 01-JAN-00:15 2384.18 30-APR-15:45
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT 4.58 0.00 01-JAN-04:45 1138.66 30-JUN-17:30
EnergyTransfer:Zone:F6 N2 APARTMENT 6.36 0.02 11-DEC-03:45 2375.28 30-APR-15:45
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT 1.76 0.00 01-JAN-00:15 2375.28 30-APR-15:45
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT 4.59 0.00 01-JAN-04:45 1126.64 30-JUN-17:30
EnergyTransfer:Zone:F6 S1 APARTMENT 7.62 0.02 08-OCT-09:00 1877.81 19-NOV-14:00
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT 0.82 0.00 01-JAN-00:15 1827.67 21-JUN-14:45
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT 6.80 0.00 19-JAN-12:45 1877.81 19-NOV-14:00
EnergyTransfer:Zone:F6 S2 APARTMENT 7.61 0.02 11-MAR-12:30 1879.14 19-NOV-14:00
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT 0.82 0.00 01-JAN-00:15 1831.61 21-JUN-14:45
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT 6.78 0.00 19-JAN-12:45 1879.14 19-NOV-14:00
EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F7 SW APARTMENT 5.79 0.00 27-AUG-09:00 2528.33 30-JUN-16:45
Heating:EnergyTransfer:Zone:F7 SW APARTMENT 1.89 0.00 01-JAN-00:15 2111.19 17-MAY-20:00
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT 3.90 0.00 03-JAN-03:45 2528.33 30-JUN-16:45
EnergyTransfer:Zone:F7 NW APARTMENT 5.76 0.00 27-MAY-04:15 2719.20 03-OCT-10:00
Heating:EnergyTransfer:Zone:F7 NW APARTMENT 3.92 0.00 01-JAN-00:45 2719.20 03-OCT-10:00
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT 1.84 0.00 01-JAN-00:15 2143.42 30-JUN-17:15
EnergyTransfer:Zone:F7 SE APARTMENT 6.28 0.05 31-JUL-03:45 2275.61 16-SEP-14:00
Heating:EnergyTransfer:Zone:F7 SE APARTMENT 1.89 0.00 01-JAN-00:15 2234.35 22-APR-14:45
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT 4.39 0.00 03-JAN-13:15 2275.61 16-SEP-14:00
EnergyTransfer:Zone:F7 NE APARTMENT 6.45 0.03 06-OCT-10:00 2865.45 22-APR-14:45
Heating:EnergyTransfer:Zone:F7 NE APARTMENT 3.96 0.00 01-JAN-00:45 2865.45 22-APR-14:45
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT 2.49 0.00 01-JAN-00:15 1602.34 09-AUG-15:30
EnergyTransfer:Zone:F7 N1 APARTMENT 6.53 0.02 27-JUN-09:30 2491.09 30-APR-15:00
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT 2.20 0.00 01-JAN-00:15 2491.09 30-APR-15:00
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT 4.33 0.00 01-JAN-04:45 1129.60 30-JUN-17:15
EnergyTransfer:Zone:F7 N2 APARTMENT 6.55 0.00 21-OCT-13:45 2474.95 30-APR-15:00
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT 2.21 0.00 01-JAN-00:15 2474.95 30-APR-15:00
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT 4.34 0.00 01-JAN-04:45 1117.92 30-JUN-17:15
EnergyTransfer:Zone:F7 S1 APARTMENT 7.45 0.02 02-OCT-09:30 2027.94 21-JUN-14:45
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT 1.05 0.00 01-JAN-00:15 2027.94 21-JUN-14:45
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT 6.39 0.00 19-JAN-12:45 1849.58 19-NOV-14:00
EnergyTransfer:Zone:F7 S2 APARTMENT 7.44 0.01 11-MAY-08:00 2030.85 21-JUN-14:45
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT 1.06 0.00 01-JAN-00:15 2030.85 21-JUN-14:45
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT 6.38 0.00 19-JAN-12:45 1850.88 19-NOV-14:00
EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F8 SW APARTMENT 5.87 0.01 02-JUN-23:15 2524.44 30-JUN-16:45
Heating:EnergyTransfer:Zone:F8 SW APARTMENT 2.30 0.00 01-JAN-00:15 2275.50 16-APR-13:00
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT 3.57 0.00 03-JAN-03:45 2524.44 30-JUN-16:45
EnergyTransfer:Zone:F8 NW APARTMENT 6.32 0.02 31-OCT-15:00 2913.35 03-OCT-10:00
Heating:EnergyTransfer:Zone:F8 NW APARTMENT 4.62 0.00 01-JAN-00:45 2913.35 03-OCT-10:00
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT 1.70 0.00 01-JAN-00:15 2138.20 30-JUN-17:15
EnergyTransfer:Zone:F8 SE APARTMENT 6.35 0.00 17-FEB-12:15 2476.25 22-APR-14:45
Heating:EnergyTransfer:Zone:F8 SE APARTMENT 2.31 0.00 01-JAN-00:15 2476.25 22-APR-14:45
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT 4.04 0.00 03-JAN-06:45 2274.78 16-SEP-14:00
EnergyTransfer:Zone:F8 NE APARTMENT 6.99 0.00 19-JUL-03:15 3068.18 22-APR-14:45
Heating:EnergyTransfer:Zone:F8 NE APARTMENT 4.67 0.00 01-JAN-00:45 3068.18 22-APR-14:45
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT 2.31 0.00 01-JAN-00:15 1594.33 30-JUN-17:15
EnergyTransfer:Zone:F8 N1 APARTMENT 6.74 0.01 18-JUN-09:00 2508.99 20-NOV-19:00
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT 2.64 0.00 01-JAN-00:15 2508.99 20-NOV-19:00
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT 4.10 0.00 01-JAN-04:30 1132.55 30-JUN-17:15
EnergyTransfer:Zone:F8 N2 APARTMENT 6.76 0.01 13-NOV-15:15 2494.06 20-NOV-19:00
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT 2.65 0.00 01-JAN-00:15 2494.06 20-NOV-19:00
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT 4.11 0.00 01-JAN-04:30 1121.06 30-JUN-17:15
EnergyTransfer:Zone:F8 S1 APARTMENT 7.32 0.01 24-MAY-04:45 2198.14 30-APR-15:45
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT 1.30 0.00 01-JAN-00:15 2198.14 30-APR-15:45
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT 6.02 0.00 19-JAN-12:45 1836.47 16-SEP-15:45
EnergyTransfer:Zone:F8 S2 APARTMENT 7.31 0.03 22-JUL-09:00 2196.86 21-JUN-14:45
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT 1.31 0.00 01-JAN-00:15 2196.86 21-JUN-14:45
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT 6.00 0.00 19-JAN-12:45 1844.04 16-SEP-15:45
EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F9 SW APARTMENT 5.96 0.01 21-DEC-15:00 2579.61 30-JUN-16:45
Heating:EnergyTransfer:Zone:F9 SW APARTMENT 2.85 0.00 01-JAN-00:15 2536.10 16-APR-13:00
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT 3.11 0.00 02-JAN-07:45 2579.61 30-JUN-16:45
EnergyTransfer:Zone:F9 NW APARTMENT 6.93 0.00 24-SEP-23:45 3121.41 03-OCT-10:00
Heating:EnergyTransfer:Zone:F9 NW APARTMENT 5.46 0.00 01-JAN-01:00 3121.41 03-OCT-10:00
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT 1.48 0.00 01-JAN-00:15 2199.21 30-JUN-17:15
EnergyTransfer:Zone:F9 SE APARTMENT 6.40 0.02 22-APR-16:00 2682.76 22-APR-14:45
Heating:EnergyTransfer:Zone:F9 SE APARTMENT 2.83 0.00 01-JAN-00:15 2682.76 22-APR-14:45
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT 3.57 0.00 03-JAN-04:00 2311.47 16-SEP-13:45
EnergyTransfer:Zone:F9 NE APARTMENT 7.58 0.01 17-NOV-15:30 3250.86 22-APR-14:45
Heating:EnergyTransfer:Zone:F9 NE APARTMENT 5.47 0.00 01-JAN-01:00 3250.86 22-APR-14:45
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT 2.11 0.00 01-JAN-00:15 1621.82 09-AUG-15:30
EnergyTransfer:Zone:F9 N1 APARTMENT 6.85 0.00 07-AUG-09:15 2664.80 20-NOV-19:00
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT 3.12 0.00 01-JAN-00:15 2664.80 20-NOV-19:00
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT 3.73 0.00 01-JAN-03:00 1192.03 30-JUN-17:15
EnergyTransfer:Zone:F9 N2 APARTMENT 6.86 0.01 06-AUG-10:15 2649.87 20-NOV-19:00
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT 3.13 0.00 01-JAN-00:15 2649.87 20-NOV-19:00
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT 3.73 0.00 01-JAN-03:00 1180.68 30-JUN-17:15
EnergyTransfer:Zone:F9 S1 APARTMENT 7.04 0.03 27-OCT-14:00 2344.64 30-APR-15:45
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT 1.57 0.00 01-JAN-00:15 2344.64 30-APR-15:45
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT 5.47 0.00 19-JAN-12:45 1877.46 16-SEP-15:45
EnergyTransfer:Zone:F9 S2 APARTMENT 7.03 0.00 04-AUG-19:30 2337.89 21-JUN-14:45
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT 1.57 0.00 01-JAN-00:15 2337.89 21-JUN-14:45
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT 5.45 0.00 19-JAN-12:45 1886.02 16-SEP-15:45
EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:T SW APARTMENT 9.58 0.01 12-FEB-19:30 3222.31 30-JUN-16:45
Heating:EnergyTransfer:Zone:T SW APARTMENT 6.11 0.00 01-JAN-00:30 2993.85 16-APR-13:00
Cooling:EnergyTransfer:Zone:T SW APARTMENT 3.47 0.00 01-JAN-00:15 3222.31 30-JUN-16:45
EnergyTransfer:Zone:T NW APARTMENT 9.90 0.00 17-APR-22:15 3526.93 20-NOV-19:00
Heating:EnergyTransfer:Zone:T NW APARTMENT 8.71 0.00 01-JAN-09:45 3526.93 20-NOV-19:00
Cooling:EnergyTransfer:Zone:T NW APARTMENT 1.19 0.00 01-JAN-00:15 2730.19 30-JUN-16:45
EnergyTransfer:Zone:T SE APARTMENT 9.78 0.00 11-JAN-19:45 3092.94 11-SEP-18:15
Heating:EnergyTransfer:Zone:T SE APARTMENT 6.00 0.00 01-JAN-00:30 3092.94 11-SEP-18:15
Cooling:EnergyTransfer:Zone:T SE APARTMENT 3.78 0.00 01-JAN-00:15 2907.62 16-SEP-13:45
EnergyTransfer:Zone:T NE APARTMENT 10.30 0.03 02-APR-23:30 3605.59 20-NOV-19:00
Heating:EnergyTransfer:Zone:T NE APARTMENT 8.66 0.00 01-JAN-08:30 3605.59 20-NOV-19:00
Cooling:EnergyTransfer:Zone:T NE APARTMENT 1.64 0.00 01-JAN-00:15 2071.00 09-AUG-15:30
EnergyTransfer:Zone:T N1 APARTMENT 6.96 0.02 06-MAR-12:45 3198.90 20-NOV-19:00
Heating:EnergyTransfer:Zone:T N1 APARTMENT 4.59 0.00 01-JAN-09:00 3198.90 20-NOV-19:00
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 2.37 0.00 01-JAN-00:15 1645.71 09-AUG-15:30
EnergyTransfer:Zone:T N2 APARTMENT 6.97 0.00 03-APR-12:15 3205.79 20-NOV-19:00
Heating:EnergyTransfer:Zone:T N2 APARTMENT 4.61 0.00 01-JAN-09:00 3205.79 20-NOV-19:00
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 2.36 0.00 01-JAN-00:15 1646.21 09-AUG-15:30
EnergyTransfer:Zone:T S1 APARTMENT 7.10 0.00 08-OCT-23:30 2664.49 11-SEP-18:15
Heating:EnergyTransfer:Zone:T S1 APARTMENT 2.59 0.00 01-JAN-00:15 2664.49 11-SEP-18:15
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 4.51 0.00 01-JAN-04:15 2468.24 06-OCT-13:15
EnergyTransfer:Zone:T S2 APARTMENT 7.12 0.01 08-FEB-12:30 2688.31 11-SEP-18:15
Heating:EnergyTransfer:Zone:T S2 APARTMENT 2.61 0.00 01-JAN-00:15 2688.31 11-SEP-18:15
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 4.51 0.00 01-JAN-04:15 2472.31 06-OCT-13:15
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Plant 946.96 478.53 10-AUG-01:15 126967.28 17-MAY-20:00
WaterSystems:EnergyTransfer 850.23 478.53 10-AUG-01:15 53998.36 03-FEB-08:00
sub cat:WaterSystems:EnergyTransfer 850.23 478.53 10-AUG-01:15 53998.36 03-FEB-08:00
EnergyTransfer:HVAC 339.70 0.00 16-JAN-11:00 169155.80 03-AUG-14:30
CoolingCoils:EnergyTransfer 141.98 0.00 01-JAN-00:15 169155.80 03-AUG-14:30
HeatingCoils:EnergyTransfer 197.72 0.00 02-JAN-13:00 135468.38 11-SEP-18:15
PlantLoopHeatingDemand:HVAC 150.15 0.00 02-JAN-13:00 93381.13 17-MAY-20:00
HeatingCoils:PlantLoopHeatingDemand 150.15 0.00 02-JAN-13:00 93381.13 17-MAY-20:00
Boilers:EnergyTransfer 96.73 0.00 01-JAN-00:15 90134.54 17-MAY-20:15



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:07

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 1.071 -3.493 0.000 0.000 3.898 1.087 12.213 16.904 0.000 0.046 0.000 0.000 -8.678 0.000 -11.488 -11.559
G NW APARTMENT 2.611 -2.069 0.000 0.000 3.970 1.087 12.213 8.339 0.000 0.047 0.000 0.000 -8.442 0.000 -10.426 -7.328
OFFICE 0.319 -13.605 0.000 0.000 0.508 29.882 9.495 16.184 0.000 0.020 0.000 0.000 -8.936 0.000 -5.195 -28.673
G NE APARTMENT 2.598 -2.533 0.000 0.000 3.997 1.087 12.213 7.759 0.000 0.046 0.000 0.000 -8.186 0.000 -10.231 -6.749
G N1 APARTMENT 1.575 -3.656 0.000 0.000 3.992 1.087 12.213 2.541 0.000 0.040 0.000 0.000 -5.158 0.000 -8.041 -4.592
G N2 APARTMENT 1.586 -3.664 0.000 0.000 3.994 1.087 12.213 2.541 0.000 0.040 0.000 0.000 -5.151 0.000 -8.032 -4.613
G S1 APARTMENT 0.397 -5.227 0.000 0.000 3.886 1.087 12.213 11.278 0.000 0.038 0.000 0.000 -5.399 0.000 -9.159 -9.114
G S2 APARTMENT 0.331 -5.270 0.000 0.000 3.873 1.087 12.213 11.248 0.000 0.038 0.000 0.000 -5.430 0.000 -9.295 -8.795
F2 SW APARTMENT 0.781 -4.683 0.000 0.000 3.768 1.087 12.213 15.784 0.000 0.061 0.001 0.000 -9.572 0.000 -15.540 -3.898
F2 NW APARTMENT 1.771 -2.319 0.000 0.000 3.914 1.087 12.213 7.562 0.000 0.061 0.000 0.000 -9.063 0.000 -13.813 -1.414
F2 SE APARTMENT 0.609 -5.764 0.000 0.000 3.744 1.087 12.213 15.338 0.000 0.061 0.001 0.000 -9.649 0.000 -15.942 -1.696
F2 NE APARTMENT 1.671 -3.041 0.000 0.000 3.951 1.087 12.213 7.146 0.000 0.061 0.000 0.000 -8.746 0.000 -13.556 -0.786
F2 N1 APARTMENT 0.864 -4.666 0.000 0.000 3.931 1.087 12.213 2.191 0.000 0.050 0.412 0.000 -5.605 0.000 -10.477 -0.000
F2 N2 APARTMENT 0.873 -4.671 0.000 0.000 3.934 1.087 12.213 2.192 0.000 0.050 0.378 0.000 -5.595 0.000 -10.460 -0.001
F2 S1 APARTMENT 0.276 -6.515 0.000 0.000 3.735 1.087 12.213 10.633 0.000 0.050 0.000 0.000 -5.977 0.000 -12.295 -3.208
F2 S2 APARTMENT 0.268 -6.583 0.000 0.000 3.730 1.087 12.213 10.622 0.000 0.050 0.000 0.000 -5.993 0.000 -12.355 -3.038
F3 SW APARTMENT 0.870 -5.051 0.000 0.000 3.757 1.087 12.213 15.325 0.000 0.074 0.000 0.000 -9.791 0.000 -17.490 -0.992
F3 NW APARTMENT 1.891 -2.410 0.000 0.000 3.913 1.087 12.213 7.249 0.000 0.074 0.808 0.000 -9.240 0.000 -15.583 -0.000
F3 SE APARTMENT 0.731 -5.742 0.000 0.000 3.772 1.087 12.213 15.059 0.000 0.073 0.000 0.000 -9.676 0.000 -17.451 -0.067
F3 NE APARTMENT 1.842 -3.160 0.000 0.000 3.948 1.087 12.213 6.910 0.000 0.073 1.325 0.000 -8.913 0.000 -15.325 -0.000
F3 N1 APARTMENT 0.969 -4.898 0.000 0.000 3.915 1.087 12.213 2.064 0.000 0.060 2.184 0.000 -5.754 0.000 -11.840 0.000
F3 N2 APARTMENT 0.979 -4.902 0.000 0.000 3.918 1.087 12.213 2.066 0.000 0.060 2.145 0.000 -5.744 0.000 -11.822 0.000
F3 S1 APARTMENT 0.366 -7.242 0.000 0.000 3.708 1.087 12.213 10.362 0.000 0.060 0.001 0.000 -6.150 0.000 -13.826 -0.578
F3 S2 APARTMENT 0.364 -7.263 0.000 0.000 3.707 1.087 12.213 10.358 0.000 0.060 0.000 0.000 -6.151 0.000 -13.842 -0.534
F4 SW APARTMENT 0.961 -5.020 0.000 0.000 3.764 1.087 12.213 15.049 0.000 0.080 0.000 0.000 -9.861 0.000 -18.158 -0.114
F4 NW APARTMENT 2.060 -2.356 0.000 0.000 3.918 1.087 12.213 7.060 0.000 0.080 1.496 0.000 -9.315 0.000 -16.242 -0.000
F4 SE APARTMENT 0.882 -5.574 0.000 0.000 3.787 1.087 12.213 14.858 0.000 0.080 0.397 0.000 -9.698 0.000 -18.031 -0.000
F4 NE APARTMENT 2.028 -3.115 0.000 0.000 3.951 1.087 12.213 6.769 0.000 0.080 1.979 0.000 -8.988 0.000 -16.003 -0.000
F4 N1 APARTMENT 1.022 -4.931 0.000 0.000 3.911 1.087 12.213 1.991 0.000 0.065 2.693 0.000 -5.828 0.000 -12.222 0.000
F4 N2 APARTMENT 1.032 -4.938 0.000 0.000 3.914 1.087 12.213 1.992 0.000 0.065 2.658 0.000 -5.818 0.000 -12.205 0.000
F4 S1 APARTMENT 0.440 -7.456 0.000 0.000 3.706 1.087 12.213 10.198 0.000 0.065 0.154 0.000 -6.216 0.000 -14.191 -0.000
F4 S2 APARTMENT 0.443 -7.446 0.000 0.000 3.706 1.087 12.213 10.197 0.000 0.065 0.139 0.000 -6.212 0.000 -14.193 -0.000
M SW APARTMENT 1.166 -4.800 0.000 0.000 3.777 1.087 12.213 14.854 0.000 0.085 0.704 0.000 -9.887 0.000 -19.199 -0.001
M NW APARTMENT 2.408 -2.262 0.000 0.000 3.926 1.087 12.213 6.925 0.000 0.085 2.245 0.000 -9.361 0.000 -17.264 -0.000
M SE APARTMENT 1.111 -5.322 0.000 0.000 3.800 1.087 12.213 14.705 0.000 0.085 1.095 0.000 -9.713 0.000 -19.060 -0.000
M NE APARTMENT 2.393 -3.020 0.000 0.000 3.956 1.087 12.213 6.667 0.000 0.085 2.703 0.000 -9.038 0.000 -17.046 -0.000
M N1 APARTMENT 1.255 -4.867 0.000 0.000 3.913 1.087 12.213 1.941 0.000 0.069 3.282 0.000 -5.875 0.000 -13.017 0.000
M N2 APARTMENT 1.266 -4.875 0.000 0.000 3.916 1.087 12.213 1.942 0.000 0.069 3.252 0.000 -5.866 0.000 -13.002 0.000
M S1 APARTMENT 0.585 -7.350 0.000 0.000 3.712 1.087 12.213 10.083 0.000 0.069 0.844 0.000 -6.247 0.000 -14.995 -0.000
M S2 APARTMENT 0.590 -7.331 0.000 0.000 3.714 1.087 12.213 10.082 0.000 0.069 0.813 0.000 -6.242 0.000 -14.993 -0.000
F6 SW APARTMENT 1.518 -4.282 0.000 0.000 3.810 1.087 12.213 14.759 0.000 0.089 0.432 0.000 -9.793 0.000 -19.832 -0.000
F6 NW APARTMENT 3.194 -2.027 0.000 0.000 3.951 1.087 12.213 6.872 0.000 0.089 1.841 0.000 -9.295 0.000 -17.925 -0.000
F6 SE APARTMENT 1.490 -4.785 0.000 0.000 3.832 1.087 12.213 14.636 0.000 0.089 0.766 0.000 -9.619 0.000 -19.708 -0.000
F6 NE APARTMENT 3.219 -2.720 0.000 0.000 3.978 1.087 12.213 6.640 0.000 0.089 2.219 0.000 -8.982 0.000 -17.741 -0.000
F6 N1 APARTMENT 1.752 -4.584 0.000 0.000 3.938 1.087 12.213 1.933 0.000 0.072 2.928 0.000 -5.835 0.000 -13.505 0.000
F6 N2 APARTMENT 1.763 -4.592 0.000 0.000 3.941 1.087 12.213 1.934 0.000 0.072 2.903 0.000 -5.827 0.000 -13.493 0.000
F6 S1 APARTMENT 0.818 -6.804 0.000 0.000 3.742 1.087 12.213 10.025 0.000 0.072 0.503 0.000 -6.198 0.000 -15.457 -0.000
F6 S2 APARTMENT 0.823 -6.785 0.000 0.000 3.743 1.087 12.213 10.025 0.000 0.072 0.471 0.000 -6.193 0.000 -15.456 -0.000
F7 SW APARTMENT 1.893 -3.895 0.000 0.000 3.835 1.087 12.213 14.670 0.000 0.093 0.221 0.000 -9.727 0.000 -20.390 -0.000
F7 NW APARTMENT 3.919 -1.845 0.000 0.000 3.969 1.087 12.213 6.816 0.000 0.093 1.545 0.000 -9.258 0.000 -18.538 -0.000
F7 SE APARTMENT 1.890 -4.386 0.000 0.000 3.856 1.087 12.213 14.568 0.000 0.093 0.519 0.000 -9.556 0.000 -20.283 -0.000
F7 NE APARTMENT 3.962 -2.493 0.000 0.000 3.992 1.087 12.213 6.604 0.000 0.092 1.878 0.000 -8.954 0.000 -18.380 -0.000
F7 N1 APARTMENT 2.200 -4.333 0.000 0.000 3.956 1.087 12.213 1.922 0.000 0.075 2.642 0.000 -5.812 0.000 -13.949 0.000
F7 N2 APARTMENT 2.210 -4.340 0.000 0.000 3.958 1.087 12.213 1.922 0.000 0.075 2.621 0.000 -5.805 0.000 -13.940 0.000
F7 S1 APARTMENT 1.053 -6.395 0.000 0.000 3.766 1.087 12.213 9.973 0.000 0.075 0.245 0.000 -6.161 0.000 -15.855 -0.000
F7 S2 APARTMENT 1.058 -6.377 0.000 0.000 3.767 1.087 12.213 9.972 0.000 0.075 0.217 0.000 -6.156 0.000 -15.854 -0.001
F8 SW APARTMENT 2.302 -3.567 0.000 0.000 3.856 1.087 12.213 14.591 0.000 0.097 0.074 0.000 -9.675 0.000 -20.978 -0.000
F8 NW APARTMENT 4.619 -1.696 0.000 0.000 3.981 1.087 12.213 6.761 0.000 0.097 1.365 0.000 -9.239 0.000 -19.187 -0.000
F8 SE APARTMENT 2.315 -4.040 0.000 0.000 3.875 1.087 12.213 14.506 0.000 0.097 0.345 0.000 -9.508 0.000 -20.889 -0.000
F8 NE APARTMENT 4.674 -2.314 0.000 0.000 4.001 1.087 12.213 6.567 0.000 0.097 1.666 0.000 -8.942 0.000 -19.049 -0.000
F8 N1 APARTMENT 2.641 -4.103 0.000 0.000 3.968 1.087 12.213 1.907 0.000 0.079 2.447 0.000 -5.800 0.000 -14.439 0.000
F8 N2 APARTMENT 2.648 -4.108 0.000 0.000 3.970 1.087 12.213 1.907 0.000 0.079 2.430 0.000 -5.793 0.000 -14.432 0.000
F8 S1 APARTMENT 1.300 -6.017 0.000 0.000 3.786 1.087 12.213 9.927 0.000 0.079 0.046 0.000 -6.130 0.000 -16.290 -0.000
F8 S2 APARTMENT 1.305 -6.002 0.000 0.000 3.787 1.087 12.213 9.926 0.000 0.079 0.022 0.000 -6.126 0.000 -16.291 -0.000
F9 SW APARTMENT 2.848 -3.110 0.000 0.000 3.875 1.087 12.213 14.538 0.000 0.100 0.000 0.000 -9.619 0.000 -21.521 -0.411
F9 NW APARTMENT 5.455 -1.479 0.000 0.000 3.988 1.087 12.213 6.716 0.000 0.101 0.967 0.000 -9.229 0.000 -19.818 -0.001
F9 SE APARTMENT 2.832 -3.569 0.000 0.000 3.893 1.087 12.213 14.469 0.000 0.100 0.001 0.000 -9.455 0.000 -21.446 -0.122
F9 NE APARTMENT 5.465 -2.115 0.000 0.000 4.008 1.087 12.213 6.538 0.000 0.100 1.325 0.000 -8.934 0.000 -19.687 -0.000
F9 N1 APARTMENT 3.124 -3.725 0.000 0.000 3.976 1.087 12.213 1.898 0.000 0.082 2.045 0.000 -5.789 0.000 -14.909 -0.000
F9 N2 APARTMENT 3.127 -3.731 0.000 0.000 3.978 1.087 12.213 1.897 0.000 0.082 2.036 0.000 -5.783 0.000 -14.903 -0.000
F9 S1 APARTMENT 1.570 -5.466 0.000 0.000 3.808 1.087 12.213 9.902 0.000 0.082 0.000 0.000 -6.089 0.000 -16.671 -0.435
F9 S2 APARTMENT 1.574 -5.451 0.000 0.000 3.809 1.087 12.213 9.901 0.000 0.082 0.000 0.000 -6.084 0.000 -16.673 -0.456
T SW APARTMENT 6.108 -3.468 0.000 0.000 3.937 1.087 12.213 14.197 0.000 0.102 0.000 0.000 -9.056 0.000 -22.342 -2.778
T NW APARTMENT 8.709 -1.194 0.000 0.000 4.009 1.087 12.213 6.413 0.000 0.102 0.000 0.000 -8.830 0.000 -20.807 -1.702
T SE APARTMENT 6.001 -3.782 0.000 0.000 3.954 1.087 12.213 14.169 0.000 0.102 0.000 0.000 -8.929 0.000 -22.239 -2.576
T NE APARTMENT 8.657 -1.641 0.000 0.000 4.027 1.087 12.213 6.288 0.000 0.100 0.000 0.000 -8.586 0.000 -20.665 -1.479
T N1 APARTMENT 4.593 -2.366 0.000 0.000 4.003 1.087 12.213 1.797 0.000 0.081 0.000 0.000 -5.528 0.000 -15.605 -0.275
T N2 APARTMENT 4.610 -2.359 0.000 0.000 4.004 1.087 12.213 1.793 0.000 0.081 0.000 0.000 -5.520 0.000 -15.610 -0.298
T S1 APARTMENT 2.593 -4.507 0.000 0.000 3.885 1.087 12.213 9.748 0.000 0.083 0.000 0.000 -5.768 0.000 -17.246 -2.087
T S2 APARTMENT 2.606 -4.513 0.000 0.000 3.886 1.087 12.213 9.744 0.000 0.083 0.000 0.000 -5.761 0.000 -17.253 -2.091
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 3.685 0.000 0.140 22.672 0.000 -1.991 0.000 -40.946 -0.000
F2 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.607 0.000 0.003 0.000 0.000 -1.201 0.000 -1.372 -15.477
F3 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.538 0.000 0.003 0.000 0.000 -1.250 0.000 -1.673 -15.058
F4 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.499 0.000 0.003 0.000 0.000 -1.272 0.000 -1.887 -14.783
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 32.880 0.000 1.459 0.000 0.003 0.000 0.000 -1.303 0.000 -2.159 -30.879
F6 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.465 0.000 0.004 0.000 0.000 -1.270 0.000 -2.158 -14.480
F7 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.461 0.000 0.004 0.000 0.000 -1.256 0.000 -2.240 -14.410
F8 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.454 0.000 0.005 0.000 0.000 -1.250 0.000 -2.326 -14.322
F9 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.448 0.000 0.005 0.000 0.000 -1.247 0.000 -2.410 -14.236
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 8.151 1.382 0.000 0.001 0.000 0.000 -1.213 0.000 -2.666 -22.096
Total Facility 169.694 -354.054 0.000 0.000 307.130 296.560 982.450 699.339 0.000 6.144 91.107 0.000 -617.765 0.000 -1312.395 -268.207


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 15-SEP-16:15 0.00 -1964.22 0.00 0.00 84.76 64.86 588.62 1873.74 0.00 290.14 0.00 0.00 0.00 0.00 0.00 -937.90
G NW APARTMENT 30-JUN-17:30 0.00 -1662.35 0.00 0.00 140.26 87.56 588.62 1850.08 0.00 257.62 0.00 0.00 0.00 0.00 0.00 -1261.79
OFFICE 15-SEP-14:00 0.00 -3086.93 0.00 0.00 65.20 2345.88 588.62 2321.68 0.00 55.23 0.00 0.00 0.00 0.00 0.00 -2289.67
G NE APARTMENT 30-JUN-17:45 0.00 -1153.93 0.00 0.00 141.34 87.56 588.62 531.76 0.00 246.50 0.00 0.00 0.00 0.00 0.00 -441.85
G N1 APARTMENT 30-JUN-19:00 0.00 -738.79 0.00 0.00 140.03 103.77 547.42 330.74 0.00 56.55 0.00 0.00 0.00 0.00 0.00 -439.72
G N2 APARTMENT 30-JUN-19:00 0.00 -724.47 0.00 0.00 139.93 103.77 547.42 330.97 0.00 55.32 0.00 0.00 0.00 0.00 0.00 -452.94
G S1 APARTMENT 31-AUG-13:30 0.00 -1295.16 0.00 0.00 40.75 12.97 382.60 1828.64 0.00 249.26 0.00 0.00 0.00 0.00 0.00 -1219.07
G S2 APARTMENT 31-AUG-13:30 0.00 -1358.37 0.00 0.00 40.75 12.97 382.60 1826.88 0.00 249.26 0.00 0.00 0.00 0.00 0.00 -1154.10
F2 SW APARTMENT 30-JUN-16:45 0.00 -2529.07 0.00 0.00 84.76 64.86 588.62 1805.09 0.00 639.95 0.00 0.00 0.00 0.00 0.00 -654.21
F2 NW APARTMENT 30-JUN-17:30 0.00 -2148.46 0.00 0.00 140.64 87.56 588.62 1734.87 0.00 360.08 0.00 0.00 0.00 0.00 0.00 -763.31
F2 SE APARTMENT 16-SEP-13:15 0.00 -2430.12 0.00 0.00 40.71 12.97 382.60 2298.16 0.00 214.85 0.00 0.00 0.00 0.00 0.00 -519.17
F2 NE APARTMENT 30-JUN-17:30 0.00 -1580.24 0.00 0.00 140.62 87.56 588.62 481.64 0.00 361.74 0.00 0.00 0.00 0.00 0.00 -79.93
F2 N1 APARTMENT 30-JUN-19:00 0.00 -1069.23 0.00 0.00 140.98 103.77 547.42 303.84 0.00 89.67 0.00 0.00 0.00 0.00 0.00 -116.45
F2 N2 APARTMENT 30-JUN-19:00 0.00 -1056.51 0.00 0.00 140.94 103.77 547.42 304.02 0.00 88.93 0.00 0.00 0.00 0.00 0.00 -128.56
F2 S1 APARTMENT 16-SEP-15:45 0.00 -1758.07 0.00 0.00 48.90 45.40 470.89 725.91 0.00 323.87 143.10 0.00 0.00 0.00 0.00 0.00
F2 S2 APARTMENT 16-SEP-15:45 0.00 -1762.76 0.00 0.00 48.90 45.40 470.89 725.77 0.00 323.87 147.92 0.00 0.00 0.00 0.00 0.00
F3 SW APARTMENT 30-JUN-16:45 0.00 -2559.48 0.00 0.00 84.76 64.86 588.62 1754.87 0.00 715.84 0.00 0.00 0.00 0.00 0.00 -649.47
F3 NW APARTMENT 30-JUN-17:30 0.00 -2178.07 0.00 0.00 140.26 87.56 588.62 1680.78 0.00 404.14 0.00 0.00 0.00 0.00 0.00 -723.28
F3 SE APARTMENT 16-SEP-14:00 0.00 -2302.52 0.00 0.00 40.42 12.97 382.60 1775.82 0.00 234.76 0.00 0.00 0.00 0.00 0.00 -144.05
F3 NE APARTMENT 30-JUN-17:30 0.00 -1619.15 0.00 0.00 140.05 87.56 588.62 465.37 0.00 400.03 0.00 0.00 0.00 0.00 0.00 -62.48
F3 N1 APARTMENT 30-JUN-17:45 0.00 -1121.02 0.00 0.00 138.68 87.56 588.62 384.90 0.00 270.36 0.00 0.00 0.00 0.00 0.00 -349.10
F3 N2 APARTMENT 30-JUN-17:45 0.00 -1108.30 0.00 0.00 138.62 87.56 588.62 385.06 0.00 268.89 0.00 0.00 0.00 0.00 0.00 -360.45
F3 S1 APARTMENT 16-SEP-15:45 0.00 -1836.03 0.00 0.00 48.90 45.40 470.89 711.02 0.00 367.82 191.99 0.00 0.00 0.00 0.00 0.00
F3 S2 APARTMENT 16-SEP-15:45 0.00 -1840.26 0.00 0.00 48.90 45.40 470.89 710.95 0.00 368.97 195.14 0.00 0.00 0.00 0.00 0.00
F4 SW APARTMENT 15-SEP-16:15 0.00 -2569.28 0.00 0.00 84.76 64.86 588.62 1698.83 0.00 482.33 0.00 0.00 0.00 0.00 0.00 -350.12
F4 NW APARTMENT 30-JUN-17:15 0.00 -2181.81 0.00 0.00 139.91 87.56 588.62 1675.76 0.00 485.92 0.00 0.00 0.00 0.00 0.00 -795.97
F4 SE APARTMENT 16-SEP-14:00 0.00 -2293.39 0.00 0.00 40.34 12.97 382.60 1755.54 0.00 259.46 0.00 0.00 0.00 0.00 0.00 -157.53
F4 NE APARTMENT 30-JUN-17:30 0.00 -1629.94 0.00 0.00 139.75 87.56 588.62 455.46 0.00 427.86 0.00 0.00 0.00 0.00 0.00 -69.30
F4 N1 APARTMENT 30-JUN-17:45 0.00 -1138.30 0.00 0.00 138.52 87.56 588.62 375.94 0.00 290.25 0.00 0.00 0.00 0.00 0.00 -342.59
F4 N2 APARTMENT 30-JUN-17:45 0.00 -1125.78 0.00 0.00 138.46 87.56 588.62 376.08 0.00 288.50 0.00 0.00 0.00 0.00 0.00 -353.43
F4 S1 APARTMENT 19-NOV-14:00 0.00 -1874.74 0.00 0.00 40.75 12.97 388.49 2175.76 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -743.24
F4 S2 APARTMENT 19-NOV-14:00 0.00 -1877.01 0.00 0.00 40.75 12.97 388.49 2175.70 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -740.90
M SW APARTMENT 30-JUN-16:45 0.00 -2590.21 0.00 0.00 84.76 64.86 588.62 1697.20 0.00 821.27 0.00 0.00 0.00 0.00 0.00 -666.50
M NW APARTMENT 30-JUN-17:15 0.00 -2203.37 0.00 0.00 139.91 87.56 588.62 1649.25 0.00 519.24 0.00 0.00 0.00 0.00 0.00 -781.21
M SE APARTMENT 16-SEP-14:00 0.00 -2320.37 0.00 0.00 40.35 12.97 382.60 1739.99 0.00 280.78 0.00 0.00 0.00 0.00 0.00 -136.32
M NE APARTMENT 09-AUG-15:30 0.00 -1654.52 0.00 0.00 48.90 45.40 470.89 513.84 0.00 719.70 0.00 0.00 0.00 0.00 0.00 -144.21
M N1 APARTMENT 30-JUN-17:45 0.00 -1168.77 0.00 0.00 138.56 87.56 588.62 369.38 0.00 310.05 0.00 0.00 0.00 0.00 0.00 -325.39
M N2 APARTMENT 30-JUN-17:45 0.00 -1156.44 0.00 0.00 138.50 87.56 588.62 369.48 0.00 307.97 0.00 0.00 0.00 0.00 0.00 -335.68
M S1 APARTMENT 19-NOV-14:00 0.00 -1917.29 0.00 0.00 40.75 12.97 388.49 2174.66 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -699.58
M S2 APARTMENT 19-NOV-14:00 0.00 -1918.78 0.00 0.00 40.75 12.97 388.49 2174.61 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -698.04
F6 SW APARTMENT 30-JUN-16:45 0.00 -2555.40 0.00 0.00 84.76 64.86 588.62 1679.82 0.00 864.85 0.00 0.00 0.00 0.00 0.00 -727.50
F6 NW APARTMENT 30-JUN-17:15 0.00 -2161.58 0.00 0.00 139.96 87.56 588.62 1630.77 0.00 548.81 0.00 0.00 0.00 0.00 0.00 -834.13
F6 SE APARTMENT 16-SEP-14:00 0.00 -2286.88 0.00 0.00 40.36 12.97 382.60 1729.36 0.00 299.14 0.00 0.00 0.00 0.00 0.00 -177.56
F6 NE APARTMENT 09-AUG-15:30 0.00 -1621.60 0.00 0.00 48.90 45.40 470.89 512.42 0.00 758.11 0.00 0.00 0.00 0.00 0.00 -214.12
F6 N1 APARTMENT 09-AUG-15:30 0.00 -1138.91 0.00 0.00 48.90 45.40 470.89 312.28 0.00 648.82 0.00 0.00 0.00 0.00 0.00 -387.38
F6 N2 APARTMENT 09-AUG-15:30 0.00 -1127.40 0.00 0.00 48.90 45.40 470.89 312.21 0.00 644.58 0.00 0.00 0.00 0.00 0.00 -394.58
F6 S1 APARTMENT 19-NOV-14:00 0.00 -1877.72 0.00 0.00 40.75 12.97 388.49 2175.10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -739.59
F6 S2 APARTMENT 19-NOV-14:00 0.00 -1879.05 0.00 0.00 40.75 12.97 388.49 2175.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -738.21
F7 SW APARTMENT 30-JUN-16:45 0.00 -2538.96 0.00 0.00 84.76 64.86 588.62 1664.78 0.00 901.46 0.00 0.00 0.00 0.00 0.00 -765.51
F7 NW APARTMENT 30-JUN-16:45 0.00 -2143.92 0.00 0.00 84.76 64.86 588.62 1712.99 0.00 807.40 0.00 0.00 0.00 0.00 0.00 -1114.71
F7 SE APARTMENT 16-SEP-14:00 0.00 -2275.20 0.00 0.00 40.39 12.97 382.60 1719.96 0.00 315.48 0.00 0.00 0.00 0.00 0.00 -196.21
F7 NE APARTMENT 09-AUG-15:30 0.00 -1602.32 0.00 0.00 48.90 45.40 470.89 510.87 0.00 790.46 0.00 0.00 0.00 0.00 0.00 -264.21
F7 N1 APARTMENT 09-AUG-15:30 0.00 -1130.23 0.00 0.00 48.90 45.40 470.89 311.53 0.00 679.47 0.00 0.00 0.00 0.00 0.00 -425.97
F7 N2 APARTMENT 09-AUG-15:30 0.00 -1118.94 0.00 0.00 48.90 45.40 470.89 311.45 0.00 674.81 0.00 0.00 0.00 0.00 0.00 -432.51
F7 S1 APARTMENT 19-NOV-14:00 0.00 -1849.49 0.00 0.00 40.75 12.97 388.49 2175.28 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -768.00
F7 S2 APARTMENT 19-NOV-14:00 0.00 -1850.79 0.00 0.00 40.75 12.97 388.49 2175.24 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -766.65
F8 SW APARTMENT 30-JUN-16:45 0.00 -2535.27 0.00 0.00 84.76 64.86 588.62 1651.37 0.00 932.13 0.00 0.00 0.00 0.00 0.00 -786.46
F8 NW APARTMENT 30-JUN-16:45 0.00 -2139.99 0.00 0.00 84.76 64.86 588.62 1698.44 0.00 834.46 0.00 0.00 0.00 0.00 0.00 -1131.15
F8 SE APARTMENT 16-SEP-14:00 0.00 -2274.36 0.00 0.00 40.43 12.97 382.60 1711.61 0.00 330.41 0.00 0.00 0.00 0.00 0.00 -203.66
F8 NE APARTMENT 30-JUN-17:15 0.00 -1594.21 0.00 0.00 139.11 87.56 588.62 425.88 0.00 549.76 0.00 0.00 0.00 0.00 0.00 -196.72
F8 N1 APARTMENT 09-AUG-15:30 0.00 -1132.96 0.00 0.00 48.90 45.40 470.89 310.53 0.00 706.96 0.00 0.00 0.00 0.00 0.00 -449.72
F8 N2 APARTMENT 09-AUG-15:30 0.00 -1121.83 0.00 0.00 48.90 45.40 470.89 310.43 0.00 702.06 0.00 0.00 0.00 0.00 0.00 -455.85
F8 S1 APARTMENT 16-SEP-15:45 0.00 -1843.96 0.00 0.00 48.90 45.40 470.89 678.80 0.00 469.33 130.64 0.00 0.00 0.00 0.00 0.00
F8 S2 APARTMENT 16-SEP-15:45 0.00 -1851.40 0.00 0.00 48.90 45.40 470.89 678.76 0.00 471.37 136.07 0.00 0.00 0.00 0.00 0.00
F9 SW APARTMENT 30-JUN-16:45 0.00 -2590.84 0.00 0.00 84.76 64.86 588.62 1636.87 0.00 956.60 0.00 0.00 0.00 0.00 0.00 -740.87
F9 NW APARTMENT 30-JUN-16:45 0.00 -2202.48 0.00 0.00 84.76 64.86 588.62 1682.71 0.00 859.15 0.00 0.00 0.00 0.00 0.00 -1077.61
F9 SE APARTMENT 30-JUN-16:45 0.00 -2313.53 0.00 0.00 84.76 64.86 588.62 399.64 0.00 1019.90 155.76 0.00 0.00 0.00 0.00 0.00
F9 NE APARTMENT 09-AUG-15:30 0.00 -1621.82 0.00 0.00 48.90 45.40 470.89 505.32 0.00 842.07 0.00 0.00 0.00 0.00 0.00 -290.76
F9 N1 APARTMENT 30-JUN-17:15 0.00 -1191.87 0.00 0.00 137.93 87.56 588.62 309.61 0.00 455.78 0.00 0.00 0.00 0.00 0.00 -387.62
F9 N2 APARTMENT 30-JUN-17:15 0.00 -1180.53 0.00 0.00 137.82 87.56 588.62 309.51 0.00 450.93 0.00 0.00 0.00 0.00 0.00 -393.91
F9 S1 APARTMENT 16-SEP-15:45 0.00 -1884.98 0.00 0.00 48.90 45.40 470.89 674.06 0.00 483.28 162.44 0.00 0.00 0.00 0.00 0.00
F9 S2 APARTMENT 16-SEP-15:45 0.00 -1893.42 0.00 0.00 48.90 45.40 470.89 674.00 0.00 485.36 168.86 0.00 0.00 0.00 0.00 0.00
T SW APARTMENT 30-JUN-16:45 0.00 -3232.35 0.00 0.00 84.76 64.86 588.62 1588.05 0.00 1007.65 0.00 0.00 0.00 0.00 0.00 -101.58
T NW APARTMENT 30-JUN-16:45 0.00 -2748.16 0.00 0.00 84.76 64.86 588.62 1630.36 0.00 848.47 0.00 0.00 0.00 0.00 0.00 -468.91
T SE APARTMENT 16-SEP-13:45 0.00 -2907.07 0.00 0.00 40.24 12.97 382.60 1862.76 0.00 359.07 249.43 0.00 0.00 0.00 0.00 0.00
T NE APARTMENT 09-AUG-15:30 0.00 -2071.57 0.00 0.00 48.90 45.40 470.89 469.52 0.00 850.92 185.93 0.00 0.00 0.00 0.00 0.00
T N1 APARTMENT 09-AUG-15:30 0.00 -1651.71 0.00 0.00 48.90 45.40 470.89 285.62 0.00 740.84 60.05 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 09-AUG-15:30 0.00 -1652.10 0.00 0.00 48.90 45.40 470.89 285.74 0.00 742.90 58.27 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 06-OCT-13:15 0.00 -2467.57 0.00 0.00 40.75 12.97 382.60 2481.46 0.00 0.00 0.00 0.00 0.00 0.00 -237.36 -212.85
T S2 APARTMENT 06-OCT-13:15 0.00 -2471.64 0.00 0.00 40.75 12.97 382.60 2481.35 0.00 0.00 0.00 0.00 0.00 0.00 -237.36 -208.68
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 30-JUN-16:45 0.00 -142412.62 0.00 0.00 6693.84 11327.17 47312.53 57277.74 0.00 57934.32 0.00 0.00 0.00 0.00 -48.70 -38084.27


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 21-APR-11:55 1942.33 0.00 0.00 0.00 45.65 12.97 406.15 850.23 0.00 0.00 0.00 0.00 0.00 0.00 -1919.76 -1337.57
G NW APARTMENT 21-APR-11:55 1687.63 0.00 0.00 0.00 46.97 12.97 406.15 630.13 0.00 0.00 0.00 0.00 0.00 0.00 -1912.54 -871.31
OFFICE 22-DEC-05:00 806.65 0.00 0.00 0.00 0.00 469.18 194.24 0.00 0.00 0.00 47.88 0.00 -655.36 0.00 -862.59 0.00
G NE APARTMENT 21-APR-11:55 1615.99 0.00 0.00 0.00 47.09 12.97 406.15 660.00 0.00 0.00 0.00 0.00 0.00 0.00 -1912.06 -830.13
G N1 APARTMENT 21-APR-11:55 1579.10 0.00 0.00 0.00 47.08 12.97 406.15 396.05 0.00 0.00 0.00 0.00 0.00 0.00 -1787.43 -653.93
G N2 APARTMENT 21-APR-11:55 1574.47 0.00 0.00 0.00 47.09 12.97 406.15 396.09 0.00 0.00 0.00 0.00 0.00 0.00 -1787.42 -649.36
G S1 APARTMENT 21-APR-11:55 1822.55 0.00 0.00 0.00 45.36 12.97 406.15 621.40 0.00 0.00 0.00 0.00 0.00 0.00 -1798.75 -1109.68
G S2 APARTMENT 21-APR-11:55 1531.54 0.00 0.00 0.00 44.91 12.97 406.15 616.50 0.00 0.00 0.00 0.00 0.00 0.00 -1809.77 -802.30
F2 SW APARTMENT 21-APR-12:00 1615.85 0.00 0.00 0.00 44.10 12.97 406.15 713.81 0.00 0.00 0.00 0.00 0.00 0.00 -2542.84 -250.04
F2 NW APARTMENT 21-APR-11:55 2373.46 0.00 0.00 0.00 46.07 12.97 406.15 543.11 0.00 0.00 0.00 0.00 0.00 0.00 -2542.16 -839.60
F2 SE APARTMENT 21-APR-12:00 1687.37 0.00 0.00 0.00 43.15 12.97 406.15 733.22 0.00 0.00 0.00 0.00 0.00 0.00 -2544.90 -337.96
F2 NE APARTMENT 21-APR-11:55 2322.71 0.00 0.00 0.00 46.18 12.97 406.15 582.06 0.00 0.00 0.00 0.00 0.00 0.00 -2540.99 -829.08
F2 N1 APARTMENT 21-APR-11:55 2423.50 0.00 0.00 0.00 45.91 12.97 406.15 344.73 0.00 0.00 0.00 0.00 0.00 0.00 -2361.00 -872.25
F2 N2 APARTMENT 21-APR-11:55 2412.48 0.00 0.00 0.00 45.92 12.97 406.15 344.86 0.00 0.00 0.00 0.00 0.00 0.00 -2360.09 -862.29
F2 S1 APARTMENT 21-APR-12:00 1760.35 0.00 0.00 0.00 43.49 12.97 406.15 528.56 0.00 0.00 0.00 0.00 0.00 0.00 -2362.38 -389.13
F2 S2 APARTMENT 21-APR-12:00 1779.76 0.00 0.00 0.00 43.34 12.97 406.15 526.81 0.00 0.00 0.00 0.00 0.00 0.00 -2362.65 -406.38
F3 SW APARTMENT 21-APR-11:55 1848.08 0.00 0.00 0.00 43.98 12.97 406.15 663.21 0.00 0.00 6.20 0.00 0.00 0.00 -2980.60 0.00
F3 NW APARTMENT 21-APR-11:55 2659.78 0.00 0.00 0.00 46.10 12.97 406.15 511.76 0.00 0.00 0.00 0.00 0.00 0.00 -2944.31 -692.45
F3 SE APARTMENT 21-APR-12:00 1722.46 0.00 0.00 0.00 43.81 12.97 406.15 701.58 0.00 0.00 57.59 0.00 0.00 0.00 -2944.55 0.00
F3 NE APARTMENT 21-APR-11:55 2618.07 0.00 0.00 0.00 46.19 12.97 406.15 553.80 0.00 0.00 0.00 0.00 0.00 0.00 -2943.26 -693.92
F3 N1 APARTMENT 21-APR-11:55 2502.14 0.00 0.00 0.00 45.68 12.97 406.15 325.57 0.00 0.00 0.00 0.00 0.00 0.00 -2688.35 -604.15
F3 N2 APARTMENT 21-APR-11:55 2484.87 0.00 0.00 0.00 45.69 12.97 406.15 325.67 0.00 0.00 0.00 0.00 0.00 0.00 -2686.21 -589.14
F3 S1 APARTMENT 21-APR-12:00 1877.84 0.00 0.00 0.00 43.06 12.97 406.15 491.16 0.00 0.00 0.00 0.00 0.00 0.00 -2731.12 -100.05
F3 S2 APARTMENT 21-APR-12:00 1884.52 0.00 0.00 0.00 43.01 12.97 406.15 490.60 0.00 0.00 0.00 0.00 0.00 0.00 -2731.21 -106.04
F4 SW APARTMENT 24-JUN-09:40 1720.92 0.00 0.00 0.00 44.93 12.97 406.15 604.35 0.00 0.00 0.00 0.00 0.00 0.00 -2370.44 -418.88
F4 NW APARTMENT 03-OCT-09:10 2339.47 0.00 0.00 0.00 46.75 12.97 406.15 94.92 0.00 0.00 0.00 0.00 0.00 0.00 -2702.03 -198.23
F4 SE APARTMENT 17-MAY-19:10 1764.37 0.00 0.00 0.00 155.54 103.77 523.87 0.00 0.00 0.00 12.44 0.00 -423.79 0.00 -2136.20 0.00
F4 NE APARTMENT 03-OCT-09:10 2303.86 0.00 0.00 0.00 45.08 12.97 406.15 1158.24 0.00 0.00 0.00 0.00 0.00 0.00 -2711.23 -1215.06
F4 N1 APARTMENT 03-OCT-09:10 2503.77 0.00 0.00 0.00 45.76 12.97 406.15 46.58 0.00 0.00 0.00 0.00 0.00 0.00 -2491.95 -523.29
F4 N2 APARTMENT 03-OCT-09:10 2487.13 0.00 0.00 0.00 45.75 12.97 406.15 46.43 0.00 0.00 0.00 0.00 0.00 0.00 -2489.63 -508.81
F4 S1 APARTMENT 21-MAY-10:15 1686.09 0.00 0.00 0.00 43.57 12.97 412.03 517.97 0.00 0.00 0.00 0.00 0.00 0.00 -1813.15 -859.48
F4 S2 APARTMENT 21-MAY-10:15 1682.48 0.00 0.00 0.00 43.56 12.97 412.03 517.92 0.00 0.00 0.00 0.00 0.00 0.00 -1813.18 -855.78
M SW APARTMENT 24-JUN-09:40 2274.36 0.00 0.00 0.00 45.33 12.97 406.15 591.68 0.00 0.00 0.00 0.00 0.00 0.00 -2528.87 -801.62
M NW APARTMENT 30-MAY-14:10 2479.73 0.00 0.00 0.00 45.95 22.70 400.26 1055.01 0.00 0.00 0.00 0.00 0.00 0.00 -2841.35 -1162.30
M SE APARTMENT 30-MAY-14:10 2204.52 0.00 0.00 0.00 45.26 22.70 400.26 606.97 0.00 0.00 0.00 0.00 0.00 0.00 -2853.03 -426.68
M NE APARTMENT 03-OCT-09:10 2782.93 0.00 0.00 0.00 45.30 12.97 406.15 1140.59 0.00 0.00 0.00 0.00 0.00 0.00 -2914.75 -1473.18
M N1 APARTMENT 03-OCT-09:10 2545.64 0.00 0.00 0.00 45.87 12.97 406.15 41.66 0.00 0.00 0.00 0.00 0.00 0.00 -2670.75 -381.54
M N2 APARTMENT 03-OCT-09:10 2529.21 0.00 0.00 0.00 45.86 12.97 406.15 41.47 0.00 0.00 0.00 0.00 0.00 0.00 -2668.22 -367.44
M S1 APARTMENT 03-OCT-09:15 2000.49 0.00 0.00 0.00 42.04 12.97 406.15 1230.71 0.00 0.00 0.00 0.00 0.00 0.00 -2694.33 -998.03
M S2 APARTMENT 30-MAY-14:10 2012.13 0.00 0.00 0.00 44.93 22.70 400.26 495.64 0.00 0.00 0.00 0.00 0.00 0.00 -2646.15 -329.51
F6 SW APARTMENT 17-MAY-19:10 2524.21 0.00 0.00 0.00 156.80 103.77 523.87 0.00 0.00 0.00 0.00 0.00 -419.92 0.00 -2404.50 -484.23
F6 NW APARTMENT 30-MAY-14:10 2556.06 0.00 0.00 0.00 46.29 22.70 400.26 1041.64 0.00 0.00 0.00 0.00 0.00 0.00 -3020.63 -1046.32
F6 SE APARTMENT 30-MAY-14:10 2718.34 0.00 0.00 0.00 45.63 22.70 400.26 598.64 0.00 0.00 0.00 0.00 0.00 0.00 -3021.82 -763.75
F6 NE APARTMENT 03-OCT-09:10 2816.51 0.00 0.00 0.00 45.73 12.97 406.15 1131.78 0.00 0.00 0.00 0.00 0.00 0.00 -3099.55 -1313.58
F6 N1 APARTMENT 03-OCT-09:10 2506.04 0.00 0.00 0.00 46.29 12.97 406.15 41.94 0.00 0.00 0.00 0.00 0.00 0.00 -2827.55 -185.83
F6 N2 APARTMENT 03-OCT-09:10 2489.93 0.00 0.00 0.00 46.28 12.97 406.15 41.69 0.00 0.00 0.00 0.00 0.00 0.00 -2824.81 -172.22
F6 S1 APARTMENT 30-MAY-14:10 2585.85 0.00 0.00 0.00 45.25 22.70 400.26 487.32 0.00 0.00 0.00 0.00 0.00 0.00 -2799.81 -741.57
F6 S2 APARTMENT 30-MAY-14:10 2597.73 0.00 0.00 0.00 45.26 22.70 400.26 487.50 0.00 0.00 0.00 0.00 0.00 0.00 -2799.57 -753.88
F7 SW APARTMENT 03-OCT-09:10 3000.33 0.00 0.00 0.00 45.15 12.97 406.15 1236.86 0.00 0.00 0.00 0.00 0.00 0.00 -3270.32 -1431.13
F7 NW APARTMENT 03-OCT-10:00 2718.67 0.00 0.00 0.00 47.42 12.97 406.15 184.61 0.00 0.00 0.00 0.00 0.00 0.00 -3347.19 -22.63
F7 SE APARTMENT 30-MAY-14:10 2799.22 0.00 0.00 0.00 45.90 22.70 400.26 590.69 0.00 0.00 0.00 0.00 0.00 0.00 -3183.69 -675.08
F7 NE APARTMENT 03-OCT-09:10 2872.62 0.00 0.00 0.00 46.04 12.97 406.15 1123.48 0.00 0.00 0.00 0.00 0.00 0.00 -3266.48 -1194.77
F7 N1 APARTMENT 24-JUN-09:55 2497.99 0.00 0.00 0.00 46.15 12.97 406.15 302.73 0.00 0.00 0.00 0.00 0.00 0.00 -2602.34 -663.65
F7 N2 APARTMENT 24-JUN-09:55 2482.33 0.00 0.00 0.00 46.13 12.97 406.15 302.35 0.00 0.00 0.00 0.00 0.00 0.00 -2599.16 -650.78
F7 S1 APARTMENT 30-MAY-14:10 2919.18 0.00 0.00 0.00 45.52 22.70 400.26 480.42 0.00 0.00 0.00 0.00 0.00 0.00 -2942.85 -925.24
F7 S2 APARTMENT 30-MAY-14:10 2918.99 0.00 0.00 0.00 45.53 22.70 400.26 480.55 0.00 0.00 0.00 0.00 0.00 0.00 -2942.85 -925.17
F8 SW APARTMENT 03-OCT-09:10 3050.95 0.00 0.00 0.00 45.56 12.97 406.15 1226.84 0.00 0.00 0.00 0.00 0.00 0.00 -3422.95 -1319.52
F8 NW APARTMENT 03-OCT-10:00 2912.82 0.00 0.00 0.00 47.42 12.97 406.15 180.52 0.00 0.00 0.00 0.00 0.00 0.00 -3509.05 -50.82
F8 SE APARTMENT 30-MAY-14:10 2882.57 0.00 0.00 0.00 46.09 22.70 400.26 582.91 0.00 0.00 0.00 0.00 0.00 0.00 -3332.43 -602.09
F8 NE APARTMENT 22-APR-14:35 3067.77 0.00 0.00 0.00 47.42 22.70 400.26 195.04 0.00 0.00 0.00 0.00 0.00 0.00 -3704.44 -28.75
F8 N1 APARTMENT 20-NOV-19:00 2507.96 0.00 0.00 0.00 165.01 87.56 588.62 0.00 0.00 0.00 659.01 0.00 -202.96 0.00 -3805.21 0.00
F8 N2 APARTMENT 20-NOV-19:00 2493.04 0.00 0.00 0.00 165.01 87.56 588.62 0.00 0.00 0.00 666.01 0.00 -202.78 0.00 -3797.46 0.00
F8 S1 APARTMENT 30-MAY-14:10 2991.71 0.00 0.00 0.00 45.72 22.70 400.26 474.22 0.00 0.00 0.00 0.00 0.00 0.00 -3079.19 -855.43
F8 S2 APARTMENT 30-MAY-14:10 2992.14 0.00 0.00 0.00 45.73 22.70 400.26 474.30 0.00 0.00 0.00 0.00 0.00 0.00 -3079.20 -855.94
F9 SW APARTMENT 03-OCT-09:10 3096.50 0.00 0.00 0.00 46.00 12.97 406.15 1221.13 0.00 0.00 0.00 0.00 0.00 0.00 -3564.81 -1217.95
F9 NW APARTMENT 03-OCT-10:00 3120.86 0.00 0.00 0.00 47.42 12.97 406.15 178.98 0.00 0.00 0.00 0.00 0.00 0.00 -3659.51 -106.86
F9 SE APARTMENT 30-MAY-14:10 2977.14 0.00 0.00 0.00 46.16 22.70 400.26 573.76 0.00 0.00 0.00 0.00 0.00 0.00 -3470.97 -549.04
F9 NE APARTMENT 22-APR-14:35 3250.42 0.00 0.00 0.00 47.42 22.70 400.26 191.46 0.00 0.00 0.00 0.00 0.00 0.00 -3861.27 -50.98
F9 N1 APARTMENT 04-MAR-12:40 2748.11 0.00 0.00 0.00 45.12 12.97 406.15 246.33 0.00 0.00 0.00 0.00 0.00 0.00 -2499.39 -959.28
F9 N2 APARTMENT 04-MAR-12:40 2771.23 0.00 0.00 0.00 45.15 12.97 406.15 246.71 0.00 0.00 0.00 0.00 0.00 0.00 -2498.78 -983.43
F9 S1 APARTMENT 30-MAY-14:10 3071.16 0.00 0.00 0.00 45.86 22.70 400.26 468.17 0.00 0.00 0.00 0.00 0.00 0.00 -3206.15 -802.00
F9 S2 APARTMENT 30-MAY-14:10 3072.73 0.00 0.00 0.00 45.86 22.70 400.26 468.16 0.00 0.00 0.00 0.00 0.00 0.00 -3206.17 -803.54
T SW APARTMENT 03-OCT-09:25 3294.01 0.00 0.00 0.00 45.86 12.97 406.15 1313.90 0.00 0.00 0.00 0.00 0.00 0.00 -3740.43 -1332.44
T NW APARTMENT 20-NOV-19:00 3525.56 0.00 0.00 0.00 165.01 87.56 588.62 0.00 0.00 0.00 407.93 0.00 -321.42 0.00 -4453.26 0.00
T SE APARTMENT 11-SEP-18:15 3092.72 0.00 0.00 0.00 165.01 103.77 547.42 0.00 0.00 0.00 593.11 0.00 -339.05 0.00 -4162.98 0.00
T NE APARTMENT 20-NOV-19:00 3604.16 0.00 0.00 0.00 165.01 87.56 588.62 0.00 0.00 0.00 324.48 0.00 -316.51 0.00 -4453.32 0.00
T N1 APARTMENT 17-MAY-19:25 3326.26 0.00 0.00 0.00 156.27 103.77 523.87 0.00 0.00 0.00 0.00 0.00 -250.69 0.00 -2824.20 -1035.27
T N2 APARTMENT 17-MAY-19:25 3322.62 0.00 0.00 0.00 156.30 103.77 523.87 0.00 0.00 0.00 0.00 0.00 -250.52 0.00 -2824.19 -1031.85
T S1 APARTMENT 03-OCT-09:25 3264.07 0.00 0.00 0.00 44.06 12.97 406.15 1272.58 0.00 0.00 0.00 0.00 0.00 0.00 -3462.99 -1536.84
T S2 APARTMENT 03-OCT-09:25 3174.65 0.00 0.00 0.00 43.94 12.97 406.15 1270.75 0.00 0.00 0.00 0.00 0.00 0.00 -3466.24 -1442.22
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 30-MAY-14:10 141050.79 0.00 0.00 0.00 3730.31 9873.49 32370.09 49856.35 0.00 0.00 0.00 0.00 0.00 0.00 -195602.30 -41278.73



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:07

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:07

Sec1.1A-General Information

Data
Weather File San Francisco Intl Ap CA USA TMY3 WMO#=724940
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 7836.48
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.50
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
F2 SW APARTMENT 88.25 88.25 0.00 168.00
F2 NW APARTMENT 88.25 88.25 0.00 168.00
F2 SE APARTMENT 88.25 88.25 0.00 168.00
F2 NE APARTMENT 88.25 88.25 0.00 168.00
F2 N1 APARTMENT 88.25 88.25 0.00 168.00
F2 N2 APARTMENT 88.25 88.25 0.00 168.00
F2 S1 APARTMENT 88.25 88.25 0.00 168.00
F2 S2 APARTMENT 88.25 88.25 0.00 168.00
F3 SW APARTMENT 88.25 88.25 0.00 168.00
F3 NW APARTMENT 88.25 88.25 0.00 168.00
F3 SE APARTMENT 88.25 88.25 0.00 168.00
F3 NE APARTMENT 88.25 88.25 0.00 168.00
F3 N1 APARTMENT 88.25 88.25 0.00 168.00
F3 N2 APARTMENT 88.25 88.25 0.00 168.00
F3 S1 APARTMENT 88.25 88.25 0.00 168.00
F3 S2 APARTMENT 88.25 88.25 0.00 168.00
F4 SW APARTMENT 88.25 88.25 0.00 168.00
F4 NW APARTMENT 88.25 88.25 0.00 168.00
F4 SE APARTMENT 88.25 88.25 0.00 168.00
F4 NE APARTMENT 88.25 88.25 0.00 168.00
F4 N1 APARTMENT 88.25 88.25 0.00 168.00
F4 N2 APARTMENT 88.25 88.25 0.00 168.00
F4 S1 APARTMENT 88.25 88.25 0.00 168.00
F4 S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
F6 SW APARTMENT 88.25 88.25 0.00 168.00
F6 NW APARTMENT 88.25 88.25 0.00 168.00
F6 SE APARTMENT 88.25 88.25 0.00 168.00
F6 NE APARTMENT 88.25 88.25 0.00 168.00
F6 N1 APARTMENT 88.25 88.25 0.00 168.00
F6 N2 APARTMENT 88.25 88.25 0.00 168.00
F6 S1 APARTMENT 88.25 88.25 0.00 168.00
F6 S2 APARTMENT 88.25 88.25 0.00 168.00
F7 SW APARTMENT 88.25 88.25 0.00 168.00
F7 NW APARTMENT 88.25 88.25 0.00 168.00
F7 SE APARTMENT 88.25 88.25 0.00 168.00
F7 NE APARTMENT 88.25 88.25 0.00 168.00
F7 N1 APARTMENT 88.25 88.25 0.00 168.00
F7 N2 APARTMENT 88.25 88.25 0.00 168.00
F7 S1 APARTMENT 88.25 88.25 0.00 168.00
F7 S2 APARTMENT 88.25 88.25 0.00 168.00
F8 SW APARTMENT 88.25 88.25 0.00 168.00
F8 NW APARTMENT 88.25 88.25 0.00 168.00
F8 SE APARTMENT 88.25 88.25 0.00 168.00
F8 NE APARTMENT 88.25 88.25 0.00 168.00
F8 N1 APARTMENT 88.25 88.25 0.00 168.00
F8 N2 APARTMENT 88.25 88.25 0.00 168.00
F8 S1 APARTMENT 88.25 88.25 0.00 168.00
F8 S2 APARTMENT 88.25 88.25 0.00 168.00
F9 SW APARTMENT 88.25 88.25 0.00 168.00
F9 NW APARTMENT 88.25 88.25 0.00 168.00
F9 SE APARTMENT 88.25 88.25 0.00 168.00
F9 NE APARTMENT 88.25 88.25 0.00 168.00
F9 N1 APARTMENT 88.25 88.25 0.00 168.00
F9 N2 APARTMENT 88.25 88.25 0.00 168.00
F9 S1 APARTMENT 88.25 88.25 0.00 168.00
F9 S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
G CORRIDOR 77.66 0.00 77.66 0.00
F2 CORRIDOR 77.66 0.00 77.66 0.00
F3 CORRIDOR 77.66 0.00 77.66 0.00
F4 CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
F6 CORRIDOR 77.66 0.00 77.66 0.00
F7 CORRIDOR 77.66 0.00 77.66 0.00
F8 CORRIDOR 77.66 0.00 77.66 0.00
F9 CORRIDOR 77.66 0.00 77.66 0.00
T CORRIDOR 77.66 0.00 77.66 0.00
Totals 7836.48 7059.89 776.58  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 119.00
Number of hours cooling loads not met 12.75
Number of hours not met 131.75


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 296.56 11327.17 0.00 0.00 0.00 0.00
Exterior Lighting 162.73 0.00 0.00 0.00 0.00 0.00
Space Heating 55.40 0.00 134.51 118213.39 0.00 0.00
Space Cooling 45.38 47332.16 0.00 0.00 0.00 0.00
Pumps 38.45 1332.31 0.00 0.00 0.00 0.00
Heat Rejection 1.75 1520.03 0.00 0.00 0.00 0.00
Fans-Interior 473.52 15015.24 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 0.00 0.00 1093.79 68877.58 0.00 0.00
Receptacle Equipment 1137.32 57142.09 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 2247.28   1228.31   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 1137.32 2247.28
Natural Gas 0.00 1228.31
Additional 0.00 0.00
Total 1137.32 3475.58


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 37.84
Space Heating 7.07
Space Cooling 5.79
Fans-Interior 60.43
Service Water Heating 0.00
Receptacle Equipment 145.13
Miscellaneous 30.51
Subtotal 286.77


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 17.17
Service Water Heating 139.58
Miscellaneous -0.00
Subtotal 156.74


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 8.53
Space Heating 5.46
Space Cooling 1.31
Fans-Interior 13.62
Service Water Heating 31.47
Receptacle Equipment 32.72
Miscellaneous 6.88



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:07

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.176890
G NW APARTMENT DIRECT AIR 0.146906
OFFICE DIRECT AIR 0.288783
G NE APARTMENT DIRECT AIR 0.104285
G N1 APARTMENT DIRECT AIR 0.064387
G N2 APARTMENT DIRECT AIR 0.063051
G S1 APARTMENT DIRECT AIR 0.114553
G S2 APARTMENT DIRECT AIR 0.120732
F2 SW APARTMENT DIRECT AIR 0.226007
F2 NW APARTMENT DIRECT AIR 0.188896
F2 SE APARTMENT DIRECT AIR 0.222403
F2 NE APARTMENT DIRECT AIR 0.141186
F2 N1 APARTMENT DIRECT AIR 0.093676
F2 N2 APARTMENT DIRECT AIR 0.092521
F2 S1 APARTMENT DIRECT AIR 0.152813
F2 S2 APARTMENT DIRECT AIR 0.155063
F3 SW APARTMENT DIRECT AIR 0.226977
F3 NW APARTMENT DIRECT AIR 0.190759
F3 SE APARTMENT DIRECT AIR 0.204332
F3 NE APARTMENT DIRECT AIR 0.143826
F3 N1 APARTMENT DIRECT AIR 0.097757
F3 N2 APARTMENT DIRECT AIR 0.096616
F3 S1 APARTMENT DIRECT AIR 0.156377
F3 S2 APARTMENT DIRECT AIR 0.157326
F4 SW APARTMENT DIRECT AIR 0.226718
F4 NW APARTMENT DIRECT AIR 0.190712
F4 SE APARTMENT DIRECT AIR 0.202908
F4 NE APARTMENT DIRECT AIR 0.143858
F4 N1 APARTMENT DIRECT AIR 0.099020
F4 N2 APARTMENT DIRECT AIR 0.097895
F4 S1 APARTMENT DIRECT AIR 0.157223
F4 S2 APARTMENT DIRECT AIR 0.157973
M SW APARTMENT DIRECT AIR 0.228297
M NW APARTMENT DIRECT AIR 0.192443
M SE APARTMENT DIRECT AIR 0.204988
M NE APARTMENT DIRECT AIR 0.145606
M N1 APARTMENT DIRECT AIR 0.101613
M N2 APARTMENT DIRECT AIR 0.100501
M S1 APARTMENT DIRECT AIR 0.159562
M S2 APARTMENT DIRECT AIR 0.160283
F6 SW APARTMENT DIRECT AIR 0.224629
F6 NW APARTMENT DIRECT AIR 0.188774
F6 SE APARTMENT DIRECT AIR 0.201934
F6 NE APARTMENT DIRECT AIR 0.142039
F6 N1 APARTMENT DIRECT AIR 0.098978
F6 N2 APARTMENT DIRECT AIR 0.097887
F6 S1 APARTMENT DIRECT AIR 0.156567
F6 S2 APARTMENT DIRECT AIR 0.157285
F7 SW APARTMENT DIRECT AIR 0.223068
F7 NW APARTMENT DIRECT AIR 0.187197
F7 SE APARTMENT DIRECT AIR 0.200845
F7 NE APARTMENT DIRECT AIR 0.140503
F7 N1 APARTMENT DIRECT AIR 0.098182
F7 N2 APARTMENT DIRECT AIR 0.097107
F7 S1 APARTMENT DIRECT AIR 0.155491
F7 S2 APARTMENT DIRECT AIR 0.156208
F8 SW APARTMENT DIRECT AIR 0.222598
F8 NW APARTMENT DIRECT AIR 0.186737
F8 SE APARTMENT DIRECT AIR 0.200761
F8 NE APARTMENT DIRECT AIR 0.140010
F8 N1 APARTMENT DIRECT AIR 0.098397
F8 N2 APARTMENT DIRECT AIR 0.097336
F8 S1 APARTMENT DIRECT AIR 0.155432
F8 S2 APARTMENT DIRECT AIR 0.156151
F9 SW APARTMENT DIRECT AIR 0.227702
F9 NW APARTMENT DIRECT AIR 0.192041
F9 SE APARTMENT DIRECT AIR 0.204897
F9 NE APARTMENT DIRECT AIR 0.141114
F9 N1 APARTMENT DIRECT AIR 0.103573
F9 N2 APARTMENT DIRECT AIR 0.102515
F9 S1 APARTMENT DIRECT AIR 0.158850
F9 S2 APARTMENT DIRECT AIR 0.159653
T SW APARTMENT DIRECT AIR 0.283258
T NW APARTMENT DIRECT AIR 0.236387
T SE APARTMENT DIRECT AIR 0.256494
T NE APARTMENT DIRECT AIR 0.177740
T N1 APARTMENT DIRECT AIR 0.138861
T N2 APARTMENT DIRECT AIR 0.138947
T S1 APARTMENT DIRECT AIR 0.216094
T S2 APARTMENT DIRECT AIR 0.216854


Branch

Maximum Flow Rate [m3/s]
AIRLOOP G SW MAIN BRANCH 0.176890
AIRLOOP G NW MAIN BRANCH 0.146906
AIRLOOP OFFICE MAIN BRANCH 0.288783
AIRLOOP G NE MAIN BRANCH 0.104285
AIRLOOP G N1 MAIN BRANCH 0.064387
AIRLOOP G N2 MAIN BRANCH 0.063051
AIRLOOP G S1 MAIN BRANCH 0.114553
AIRLOOP G S2 MAIN BRANCH 0.120732
AIRLOOP F2 SW MAIN BRANCH 0.226007
AIRLOOP F2 NW MAIN BRANCH 0.188896
AIRLOOP F2 SE MAIN BRANCH 0.222403
AIRLOOP F2 NE MAIN BRANCH 0.141186
AIRLOOP F2 N1 MAIN BRANCH 0.093676
AIRLOOP F2 N2 MAIN BRANCH 0.092521
AIRLOOP F2 S1 MAIN BRANCH 0.152813
AIRLOOP F2 S2 MAIN BRANCH 0.155063
AIRLOOP F3 SW MAIN BRANCH 0.226977
AIRLOOP F3 NW MAIN BRANCH 0.190759
AIRLOOP F3 SE MAIN BRANCH 0.204332
AIRLOOP F3 NE MAIN BRANCH 0.143826
AIRLOOP F3 N1 MAIN BRANCH 0.097757
AIRLOOP F3 N2 MAIN BRANCH 0.096616
AIRLOOP F3 S1 MAIN BRANCH 0.156377
AIRLOOP F3 S2 MAIN BRANCH 0.157326
AIRLOOP F4 SW MAIN BRANCH 0.226718
AIRLOOP F4 NW MAIN BRANCH 0.190712
AIRLOOP F4 SE MAIN BRANCH 0.202908
AIRLOOP F4 NE MAIN BRANCH 0.143858
AIRLOOP F4 N1 MAIN BRANCH 0.099020
AIRLOOP F4 N2 MAIN BRANCH 0.097895
AIRLOOP F4 S1 MAIN BRANCH 0.157223
AIRLOOP F4 S2 MAIN BRANCH 0.157973
AIRLOOP M SW MAIN BRANCH 0.228297
AIRLOOP M NW MAIN BRANCH 0.192443
AIRLOOP M SE MAIN BRANCH 0.204988
AIRLOOP M NE MAIN BRANCH 0.145606
AIRLOOP M N1 MAIN BRANCH 0.101613
AIRLOOP M N2 MAIN BRANCH 0.100501
AIRLOOP M S1 MAIN BRANCH 0.159562
AIRLOOP M S2 MAIN BRANCH 0.160283
AIRLOOP F6 SW MAIN BRANCH 0.224629
AIRLOOP F6 NW MAIN BRANCH 0.188774
AIRLOOP F6 SE MAIN BRANCH 0.201934
AIRLOOP F6 NE MAIN BRANCH 0.142039
AIRLOOP F6 N1 MAIN BRANCH 0.098978
AIRLOOP F6 N2 MAIN BRANCH 0.097887
AIRLOOP F6 S1 MAIN BRANCH 0.156567
AIRLOOP F6 S2 MAIN BRANCH 0.157285
AIRLOOP F7 SW MAIN BRANCH 0.223068
AIRLOOP F7 NW MAIN BRANCH 0.187197
AIRLOOP F7 SE MAIN BRANCH 0.200845
AIRLOOP F7 NE MAIN BRANCH 0.140503
AIRLOOP F7 N1 MAIN BRANCH 0.098182
AIRLOOP F7 N2 MAIN BRANCH 0.097107
AIRLOOP F7 S1 MAIN BRANCH 0.155491
AIRLOOP F7 S2 MAIN BRANCH 0.156208
AIRLOOP F8 SW MAIN BRANCH 0.222598
AIRLOOP F8 NW MAIN BRANCH 0.186737
AIRLOOP F8 SE MAIN BRANCH 0.200761
AIRLOOP F8 NE MAIN BRANCH 0.140010
AIRLOOP F8 N1 MAIN BRANCH 0.098397
AIRLOOP F8 N2 MAIN BRANCH 0.097336
AIRLOOP F8 S1 MAIN BRANCH 0.155432
AIRLOOP F8 S2 MAIN BRANCH 0.156151
AIRLOOP F9 SW MAIN BRANCH 0.227702
AIRLOOP F9 NW MAIN BRANCH 0.192041
AIRLOOP F9 SE MAIN BRANCH 0.204897
AIRLOOP F9 NE MAIN BRANCH 0.141114
AIRLOOP F9 N1 MAIN BRANCH 0.103573
AIRLOOP F9 N2 MAIN BRANCH 0.102515
AIRLOOP F9 S1 MAIN BRANCH 0.158850
AIRLOOP F9 S2 MAIN BRANCH 0.159653
AIRLOOP T SW MAIN BRANCH 0.283258
AIRLOOP T NW MAIN BRANCH 0.236387
AIRLOOP T SE MAIN BRANCH 0.256494
AIRLOOP T NE MAIN BRANCH 0.177740
AIRLOOP T N1 MAIN BRANCH 0.138861
AIRLOOP T N2 MAIN BRANCH 0.138947
AIRLOOP T S1 MAIN BRANCH 0.216094
AIRLOOP T S2 MAIN BRANCH 0.216854


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
AIRLOOP G SW 0.176890
AIRLOOP G NW 0.146906
AIRLOOP OFFICE 0.288783
AIRLOOP G NE 0.104285
AIRLOOP G N1 0.064387
AIRLOOP G N2 0.063051
AIRLOOP G S1 0.114553
AIRLOOP G S2 0.120732
AIRLOOP F2 SW 0.226007
AIRLOOP F2 NW 0.188896
AIRLOOP F2 SE 0.222403
AIRLOOP F2 NE 0.141186
AIRLOOP F2 N1 0.093676
AIRLOOP F2 N2 0.092521
AIRLOOP F2 S1 0.152813
AIRLOOP F2 S2 0.155063
AIRLOOP F3 SW 0.226977
AIRLOOP F3 NW 0.190759
AIRLOOP F3 SE 0.204332
AIRLOOP F3 NE 0.143826
AIRLOOP F3 N1 0.097757
AIRLOOP F3 N2 0.096616
AIRLOOP F3 S1 0.156377
AIRLOOP F3 S2 0.157326
AIRLOOP F4 SW 0.226718
AIRLOOP F4 NW 0.190712
AIRLOOP F4 SE 0.202908
AIRLOOP F4 NE 0.143858
AIRLOOP F4 N1 0.099020
AIRLOOP F4 N2 0.097895
AIRLOOP F4 S1 0.157223
AIRLOOP F4 S2 0.157973
AIRLOOP M SW 0.228297
AIRLOOP M NW 0.192443
AIRLOOP M SE 0.204988
AIRLOOP M NE 0.145606
AIRLOOP M N1 0.101613
AIRLOOP M N2 0.100501
AIRLOOP M S1 0.159562
AIRLOOP M S2 0.160283
AIRLOOP F6 SW 0.224629
AIRLOOP F6 NW 0.188774
AIRLOOP F6 SE 0.201934
AIRLOOP F6 NE 0.142039
AIRLOOP F6 N1 0.098978
AIRLOOP F6 N2 0.097887
AIRLOOP F6 S1 0.156567
AIRLOOP F6 S2 0.157285
AIRLOOP F7 SW 0.223068
AIRLOOP F7 NW 0.187197
AIRLOOP F7 SE 0.200845
AIRLOOP F7 NE 0.140503
AIRLOOP F7 N1 0.098182
AIRLOOP F7 N2 0.097107
AIRLOOP F7 S1 0.155491
AIRLOOP F7 S2 0.156208
AIRLOOP F8 SW 0.222598
AIRLOOP F8 NW 0.186737
AIRLOOP F8 SE 0.200761
AIRLOOP F8 NE 0.140010
AIRLOOP F8 N1 0.098397
AIRLOOP F8 N2 0.097336
AIRLOOP F8 S1 0.155432
AIRLOOP F8 S2 0.156151
AIRLOOP F9 SW 0.227702
AIRLOOP F9 NW 0.192041
AIRLOOP F9 SE 0.204897
AIRLOOP F9 NE 0.141114
AIRLOOP F9 N1 0.103573
AIRLOOP F9 N2 0.102515
AIRLOOP F9 S1 0.158850
AIRLOOP F9 S2 0.159653
AIRLOOP T SW 0.283258
AIRLOOP T NW 0.236387
AIRLOOP T SE 0.256494
AIRLOOP T NE 0.177740
AIRLOOP T N1 0.138861
AIRLOOP T N2 0.138947
AIRLOOP T S1 0.216094
AIRLOOP T S2 0.216854


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
AIRLOOP G SW OA CONTROLLER 0.176890 0.025952
AIRLOOP G NW OA CONTROLLER 0.146906 0.025952
AIRLOOP OFFICE OA CONTROLLER 0.288783 0.038103
AIRLOOP G NE OA CONTROLLER 0.104285 0.025952
AIRLOOP G N1 OA CONTROLLER 0.064387 0.025952
AIRLOOP G N2 OA CONTROLLER 0.063051 0.025952
AIRLOOP G S1 OA CONTROLLER 0.114553 0.025952
AIRLOOP G S2 OA CONTROLLER 0.120732 0.025952
AIRLOOP F2 SW OA CONTROLLER 0.226007 0.025952
AIRLOOP F2 NW OA CONTROLLER 0.188896 0.025952
AIRLOOP F2 SE OA CONTROLLER 0.222403 0.025952
AIRLOOP F2 NE OA CONTROLLER 0.141186 0.025952
AIRLOOP F2 N1 OA CONTROLLER 0.093676 0.025952
AIRLOOP F2 N2 OA CONTROLLER 0.092521 0.025952
AIRLOOP F2 S1 OA CONTROLLER 0.152813 0.025952
AIRLOOP F2 S2 OA CONTROLLER 0.155063 0.025952
AIRLOOP F3 SW OA CONTROLLER 0.226977 0.025952
AIRLOOP F3 NW OA CONTROLLER 0.190759 0.025952
AIRLOOP F3 SE OA CONTROLLER 0.204332 0.025952
AIRLOOP F3 NE OA CONTROLLER 0.143826 0.025952
AIRLOOP F3 N1 OA CONTROLLER 0.097757 0.025952
AIRLOOP F3 N2 OA CONTROLLER 0.096616 0.025952
AIRLOOP F3 S1 OA CONTROLLER 0.156377 0.025952
AIRLOOP F3 S2 OA CONTROLLER 0.157326 0.025952
AIRLOOP F4 SW OA CONTROLLER 0.226718 0.025952
AIRLOOP F4 NW OA CONTROLLER 0.190712 0.025952
AIRLOOP F4 SE OA CONTROLLER 0.202908 0.025952
AIRLOOP F4 NE OA CONTROLLER 0.143858 0.025952
AIRLOOP F4 N1 OA CONTROLLER 0.099020 0.025952
AIRLOOP F4 N2 OA CONTROLLER 0.097895 0.025952
AIRLOOP F4 S1 OA CONTROLLER 0.157223 0.025952
AIRLOOP F4 S2 OA CONTROLLER 0.157973 0.025952
AIRLOOP M SW OA CONTROLLER 0.228297 0.025952
AIRLOOP M NW OA CONTROLLER 0.192443 0.025952
AIRLOOP M SE OA CONTROLLER 0.204988 0.025952
AIRLOOP M NE OA CONTROLLER 0.145606 0.025952
AIRLOOP M N1 OA CONTROLLER 0.101613 0.025952
AIRLOOP M N2 OA CONTROLLER 0.100501 0.025952
AIRLOOP M S1 OA CONTROLLER 0.159562 0.025952
AIRLOOP M S2 OA CONTROLLER 0.160283 0.025952
AIRLOOP F6 SW OA CONTROLLER 0.224629 0.025952
AIRLOOP F6 NW OA CONTROLLER 0.188774 0.025952
AIRLOOP F6 SE OA CONTROLLER 0.201934 0.025952
AIRLOOP F6 NE OA CONTROLLER 0.142039 0.025952
AIRLOOP F6 N1 OA CONTROLLER 0.098978 0.025952
AIRLOOP F6 N2 OA CONTROLLER 0.097887 0.025952
AIRLOOP F6 S1 OA CONTROLLER 0.156567 0.025952
AIRLOOP F6 S2 OA CONTROLLER 0.157285 0.025952
AIRLOOP F7 SW OA CONTROLLER 0.223068 0.025952
AIRLOOP F7 NW OA CONTROLLER 0.187197 0.025952
AIRLOOP F7 SE OA CONTROLLER 0.200845 0.025952
AIRLOOP F7 NE OA CONTROLLER 0.140503 0.025952
AIRLOOP F7 N1 OA CONTROLLER 0.098182 0.025952
AIRLOOP F7 N2 OA CONTROLLER 0.097107 0.025952
AIRLOOP F7 S1 OA CONTROLLER 0.155491 0.025952
AIRLOOP F7 S2 OA CONTROLLER 0.156208 0.025952
AIRLOOP F8 SW OA CONTROLLER 0.222598 0.025952
AIRLOOP F8 NW OA CONTROLLER 0.186737 0.025952
AIRLOOP F8 SE OA CONTROLLER 0.200761 0.025952
AIRLOOP F8 NE OA CONTROLLER 0.140010 0.025952
AIRLOOP F8 N1 OA CONTROLLER 0.098397 0.025952
AIRLOOP F8 N2 OA CONTROLLER 0.097336 0.025952
AIRLOOP F8 S1 OA CONTROLLER 0.155432 0.025952
AIRLOOP F8 S2 OA CONTROLLER 0.156151 0.025952
AIRLOOP F9 SW OA CONTROLLER 0.227702 0.025952
AIRLOOP F9 NW OA CONTROLLER 0.192041 0.025952
AIRLOOP F9 SE OA CONTROLLER 0.204897 0.025952
AIRLOOP F9 NE OA CONTROLLER 0.141114 0.025952
AIRLOOP F9 N1 OA CONTROLLER 0.103573 0.025952
AIRLOOP F9 N2 OA CONTROLLER 0.102515 0.025952
AIRLOOP F9 S1 OA CONTROLLER 0.158850 0.025952
AIRLOOP F9 S2 OA CONTROLLER 0.159653 0.025952
AIRLOOP T SW OA CONTROLLER 0.283258 0.025952
AIRLOOP T NW OA CONTROLLER 0.236387 0.025952
AIRLOOP T SE OA CONTROLLER 0.256494 0.025952
AIRLOOP T NE OA CONTROLLER 0.177740 0.025952
AIRLOOP T N1 OA CONTROLLER 0.138861 0.025952
AIRLOOP T N2 OA CONTROLLER 0.138947 0.025952
AIRLOOP T S1 OA CONTROLLER 0.216094 0.025952
AIRLOOP T S2 OA CONTROLLER 0.216854 0.025952


COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity [W] Rated Sensible Cooling Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP COOLING MODE AIRLOOP G SW 0.176890 2563.84 1990.97 0.000056
HEAT PUMP COOLING MODE AIRLOOP G NW 0.146906 2112.46 1645.03 0.000046
HEAT PUMP COOLING MODE AIRLOOP OFFICE 0.288783 4156.08 3239.54 0.000091
HEAT PUMP COOLING MODE AIRLOOP G NE 0.104285 1477.02 1157.70 0.000032
HEAT PUMP COOLING MODE AIRLOOP G N1 0.064387 931.68 723.93 0.000020
HEAT PUMP COOLING MODE AIRLOOP G N2 0.063051 912.56 709.13 0.000020
HEAT PUMP COOLING MODE AIRLOOP G S1 0.114553 1700.88 1308.59 0.000037
HEAT PUMP COOLING MODE AIRLOOP G S2 0.120732 1787.39 1376.63 0.000039
HEAT PUMP COOLING MODE AIRLOOP F2 SW 0.226007 3237.00 2525.49 0.000071
HEAT PUMP COOLING MODE AIRLOOP F2 NW 0.188896 2695.86 2105.63 0.000059
HEAT PUMP COOLING MODE AIRLOOP F2 SE 0.222403 3200.43 2492.51 0.000070
HEAT PUMP COOLING MODE AIRLOOP F2 NE 0.141186 1984.64 1561.08 0.000043
HEAT PUMP COOLING MODE AIRLOOP F2 N1 0.093676 1344.49 1046.79 0.000029
HEAT PUMP COOLING MODE AIRLOOP F2 N2 0.092521 1328.10 1034.03 0.000029
HEAT PUMP COOLING MODE AIRLOOP F2 S1 0.152813 2236.36 1730.31 0.000049
HEAT PUMP COOLING MODE AIRLOOP F2 S2 0.155063 2267.91 1755.08 0.000050
HEAT PUMP COOLING MODE AIRLOOP F3 SW 0.226977 3246.91 2535.19 0.000071
HEAT PUMP COOLING MODE AIRLOOP F3 NW 0.190759 2718.42 2125.19 0.000059
HEAT PUMP COOLING MODE AIRLOOP F3 SE 0.204332 2943.71 2292.76 0.000064
HEAT PUMP COOLING MODE AIRLOOP F3 NE 0.143826 2017.99 1589.16 0.000044
HEAT PUMP COOLING MODE AIRLOOP F3 N1 0.097757 1400.14 1091.27 0.000031
HEAT PUMP COOLING MODE AIRLOOP F3 N2 0.096616 1383.98 1078.68 0.000030
HEAT PUMP COOLING MODE AIRLOOP F3 S1 0.156377 2284.07 1768.96 0.000050
HEAT PUMP COOLING MODE AIRLOOP F3 S2 0.157326 2297.37 1779.40 0.000050
HEAT PUMP COOLING MODE AIRLOOP F4 SW 0.226718 3240.61 2531.64 0.000071
HEAT PUMP COOLING MODE AIRLOOP F4 NW 0.190712 2715.17 2124.00 0.000059
HEAT PUMP COOLING MODE AIRLOOP F4 SE 0.202908 2921.19 2276.42 0.000064
HEAT PUMP COOLING MODE AIRLOOP F4 NE 0.143858 2024.77 1593.31 0.000044
HEAT PUMP COOLING MODE AIRLOOP F4 N1 0.099020 1416.45 1104.80 0.000031
HEAT PUMP COOLING MODE AIRLOOP F4 N2 0.097895 1400.53 1092.39 0.000031
HEAT PUMP COOLING MODE AIRLOOP F4 S1 0.157223 2294.27 1777.83 0.000050
HEAT PUMP COOLING MODE AIRLOOP F4 S2 0.157973 2304.78 1786.09 0.000050
HEAT PUMP COOLING MODE AIRLOOP M SW 0.228297 3260.58 2548.45 0.000071
HEAT PUMP COOLING MODE AIRLOOP M NW 0.192443 2737.36 2142.49 0.000060
HEAT PUMP COOLING MODE AIRLOOP M SE 0.204988 2948.26 2298.77 0.000064
HEAT PUMP COOLING MODE AIRLOOP M NE 0.145606 2047.31 1612.02 0.000045
HEAT PUMP COOLING MODE AIRLOOP M N1 0.101613 1451.87 1133.08 0.000032
HEAT PUMP COOLING MODE AIRLOOP M N2 0.100501 1436.15 1120.82 0.000031
HEAT PUMP COOLING MODE AIRLOOP M S1 0.159562 2325.72 1803.23 0.000051
HEAT PUMP COOLING MODE AIRLOOP M S2 0.160283 2335.83 1811.16 0.000051
HEAT PUMP COOLING MODE AIRLOOP F6 SW 0.224629 3216.33 2511.89 0.000070
HEAT PUMP COOLING MODE AIRLOOP F6 NW 0.188774 2684.22 2101.68 0.000059
HEAT PUMP COOLING MODE AIRLOOP F6 SE 0.201934 2903.81 2264.73 0.000063
HEAT PUMP COOLING MODE AIRLOOP F6 NE 0.142039 1995.95 1572.43 0.000044
HEAT PUMP COOLING MODE AIRLOOP F6 N1 0.098978 1413.58 1103.74 0.000031
HEAT PUMP COOLING MODE AIRLOOP F6 N2 0.097887 1398.17 1091.71 0.000031
HEAT PUMP COOLING MODE AIRLOOP F6 S1 0.156567 2282.63 1769.97 0.000050
HEAT PUMP COOLING MODE AIRLOOP F6 S2 0.157285 2292.69 1777.86 0.000050
HEAT PUMP COOLING MODE AIRLOOP F7 SW 0.223068 3192.94 2494.32 0.000070
HEAT PUMP COOLING MODE AIRLOOP F7 NW 0.187197 2660.65 2083.95 0.000058
HEAT PUMP COOLING MODE AIRLOOP F7 SE 0.200845 2887.09 2252.36 0.000063
HEAT PUMP COOLING MODE AIRLOOP F7 NE 0.140503 1973.20 1555.22 0.000043
HEAT PUMP COOLING MODE AIRLOOP F7 N1 0.098182 1401.45 1094.73 0.000031
HEAT PUMP COOLING MODE AIRLOOP F7 N2 0.097107 1386.26 1082.87 0.000030
HEAT PUMP COOLING MODE AIRLOOP F7 S1 0.155491 2266.59 1757.86 0.000050
HEAT PUMP COOLING MODE AIRLOOP F7 S2 0.156208 2276.63 1765.76 0.000050
HEAT PUMP COOLING MODE AIRLOOP F8 SW 0.222598 3185.00 2488.79 0.000070
HEAT PUMP COOLING MODE AIRLOOP F8 NW 0.186737 2652.90 2078.54 0.000058
HEAT PUMP COOLING MODE AIRLOOP F8 SE 0.200761 2884.61 2251.09 0.000063
HEAT PUMP COOLING MODE AIRLOOP F8 NE 0.140010 1965.16 1549.50 0.000043
HEAT PUMP COOLING MODE AIRLOOP F8 N1 0.098397 1403.70 1096.89 0.000031
HEAT PUMP COOLING MODE AIRLOOP F8 N2 0.097336 1388.72 1085.19 0.000030
HEAT PUMP COOLING MODE AIRLOOP F8 S1 0.155432 2264.91 1756.99 0.000049
HEAT PUMP COOLING MODE AIRLOOP F8 S2 0.156151 2274.97 1764.90 0.000050
HEAT PUMP COOLING MODE AIRLOOP F9 SW 0.227702 3246.27 2540.34 0.000071
HEAT PUMP COOLING MODE AIRLOOP F9 NW 0.192041 2726.00 2136.57 0.000060
HEAT PUMP COOLING MODE AIRLOOP F9 SE 0.204897 2944.46 2297.78 0.000064
HEAT PUMP COOLING MODE AIRLOOP F9 NE 0.141114 1988.83 1565.90 0.000043
HEAT PUMP COOLING MODE AIRLOOP F9 N1 0.103573 1476.09 1153.79 0.000032
HEAT PUMP COOLING MODE AIRLOOP F9 N2 0.102515 1461.16 1142.13 0.000032
HEAT PUMP COOLING MODE AIRLOOP F9 S1 0.158850 2311.99 1794.40 0.000051
HEAT PUMP COOLING MODE AIRLOOP F9 S2 0.159653 2323.24 1803.24 0.000051
HEAT PUMP COOLING MODE AIRLOOP T SW 0.283258 4035.11 3156.96 0.000088
HEAT PUMP COOLING MODE AIRLOOP T NW 0.236387 3358.57 2631.20 0.000073
HEAT PUMP COOLING MODE AIRLOOP T SE 0.256494 3661.84 2863.28 0.000080
HEAT PUMP COOLING MODE AIRLOOP T NE 0.177740 2508.57 1972.57 0.000055
HEAT PUMP COOLING MODE AIRLOOP T N1 0.138861 2034.57 1575.70 0.000044
HEAT PUMP COOLING MODE AIRLOOP T N2 0.138947 2035.77 1576.65 0.000044
HEAT PUMP COOLING MODE AIRLOOP T S1 0.216094 3113.02 2424.04 0.000068
HEAT PUMP COOLING MODE AIRLOOP T S2 0.216854 3123.67 2432.40 0.000068


AirLoopHVAC:UnitaryHeatPump:WaterToAir

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Supplemental Heating Coil Nominal Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
AIRLOOP G SW DXAC HEAT PUMP 0.176890 0.176890 0.176890 0.176890 2563.84 2563.84 1666.56 1.00
AIRLOOP G NW DXAC HEAT PUMP 0.146906 0.146906 0.146906 0.146906 2112.46 2112.46 1672.45 1.00
AIRLOOP OFFICE DXAC HEAT PUMP 0.288783 0.288783 0.288783 0.288783 4156.08 4156.08 2242.41 1.00
AIRLOOP G NE DXAC HEAT PUMP 0.104285 0.104285 0.104285 0.104285 1477.02 1477.02 1670.56 1.00
AIRLOOP G N1 DXAC HEAT PUMP 0.064387 0.064387 0.064387 0.064387 931.68 931.68 1238.05 1.00
AIRLOOP G N2 DXAC HEAT PUMP 0.063051 0.063051 0.063051 0.063051 912.56 912.56 1238.00 1.00
AIRLOOP G S1 DXAC HEAT PUMP 0.114553 0.114553 0.114553 0.114553 1700.88 1700.88 1227.96 1.00
AIRLOOP G S2 DXAC HEAT PUMP 0.120732 0.120732 0.120732 0.120732 1787.39 1787.39 1234.08 1.00
AIRLOOP F2 SW DXAC HEAT PUMP 0.226007 0.226007 0.226007 0.226007 3237.00 3237.00 1572.32 1.00
AIRLOOP F2 NW DXAC HEAT PUMP 0.188896 0.188896 0.188896 0.188896 2695.86 2695.86 1576.60 1.00
AIRLOOP F2 SE DXAC HEAT PUMP 0.222403 0.222403 0.222403 0.222403 3200.43 3200.43 1589.50 1.00
AIRLOOP F2 NE DXAC HEAT PUMP 0.141186 0.141186 0.141186 0.141186 1984.64 1984.64 1574.69 1.00
AIRLOOP F2 N1 DXAC HEAT PUMP 0.093676 0.093676 0.093676 0.093676 1344.49 1344.49 1136.65 1.00
AIRLOOP F2 N2 DXAC HEAT PUMP 0.092521 0.092521 0.092521 0.092521 1328.10 1328.10 1136.65 1.00
AIRLOOP F2 S1 DXAC HEAT PUMP 0.152813 0.152813 0.152813 0.152813 2236.36 2236.36 1136.65 1.00
AIRLOOP F2 S2 DXAC HEAT PUMP 0.155063 0.155063 0.155063 0.155063 2267.91 2267.91 1136.65 1.00
AIRLOOP F3 SW DXAC HEAT PUMP 0.226977 0.226977 0.226977 0.226977 3246.91 3246.91 1553.36 1.00
AIRLOOP F3 NW DXAC HEAT PUMP 0.190759 0.190759 0.190759 0.190759 2718.42 2718.42 1556.84 1.00
AIRLOOP F3 SE DXAC HEAT PUMP 0.204332 0.204332 0.204332 0.204332 2943.71 2943.71 1554.12 1.00
AIRLOOP F3 NE DXAC HEAT PUMP 0.143826 0.143826 0.143826 0.143826 2017.99 2017.99 1555.28 1.00
AIRLOOP F3 N1 DXAC HEAT PUMP 0.097757 0.097757 0.097757 0.097757 1400.14 1400.14 1136.65 1.00
AIRLOOP F3 N2 DXAC HEAT PUMP 0.096616 0.096616 0.096616 0.096616 1383.98 1383.98 1136.65 1.00
AIRLOOP F3 S1 DXAC HEAT PUMP 0.156377 0.156377 0.156377 0.156377 2284.07 2284.07 1136.65 1.00
AIRLOOP F3 S2 DXAC HEAT PUMP 0.157326 0.157326 0.157326 0.157326 2297.37 2297.37 1136.65 1.00
AIRLOOP F4 SW DXAC HEAT PUMP 0.226718 0.226718 0.226718 0.226718 3240.61 3240.61 1574.01 1.00
AIRLOOP F4 NW DXAC HEAT PUMP 0.190712 0.190712 0.190712 0.190712 2715.17 2715.17 1577.31 1.00
AIRLOOP F4 SE DXAC HEAT PUMP 0.202908 0.202908 0.202908 0.202908 2921.19 2921.19 1573.04 1.00
AIRLOOP F4 NE DXAC HEAT PUMP 0.143858 0.143858 0.143858 0.143858 2024.77 2024.77 1576.07 1.00
AIRLOOP F4 N1 DXAC HEAT PUMP 0.099020 0.099020 0.099020 0.099020 1416.45 1416.45 1136.65 1.00
AIRLOOP F4 N2 DXAC HEAT PUMP 0.097895 0.097895 0.097895 0.097895 1400.53 1400.53 1136.65 1.00
AIRLOOP F4 S1 DXAC HEAT PUMP 0.157223 0.157223 0.157223 0.157223 2294.27 2294.27 1136.65 1.00
AIRLOOP F4 S2 DXAC HEAT PUMP 0.157973 0.157973 0.157973 0.157973 2304.78 2304.78 1136.65 1.00
AIRLOOP M SW DXAC HEAT PUMP 0.228297 0.228297 0.228297 0.228297 3260.58 3260.58 1578.67 1.00
AIRLOOP M NW DXAC HEAT PUMP 0.192443 0.192443 0.192443 0.192443 2737.36 2737.36 1580.66 1.00
AIRLOOP M SE DXAC HEAT PUMP 0.204988 0.204988 0.204988 0.204988 2948.26 2948.26 1577.75 1.00
AIRLOOP M NE DXAC HEAT PUMP 0.145606 0.145606 0.145606 0.145606 2047.31 2047.31 1579.71 1.00
AIRLOOP M N1 DXAC HEAT PUMP 0.101613 0.101613 0.101613 0.101613 1451.87 1451.87 1136.65 1.00
AIRLOOP M N2 DXAC HEAT PUMP 0.100501 0.100501 0.100501 0.100501 1436.15 1436.15 1136.65 1.00
AIRLOOP M S1 DXAC HEAT PUMP 0.159562 0.159562 0.159562 0.159562 2325.72 2325.72 1136.65 1.00
AIRLOOP M S2 DXAC HEAT PUMP 0.160283 0.160283 0.160283 0.160283 2335.83 2335.83 1136.65 1.00
AIRLOOP F6 SW DXAC HEAT PUMP 0.224629 0.224629 0.224629 0.224629 3216.33 3216.33 1640.86 1.00
AIRLOOP F6 NW DXAC HEAT PUMP 0.188774 0.188774 0.188774 0.188774 2684.22 2684.22 1643.30 1.00
AIRLOOP F6 SE DXAC HEAT PUMP 0.201934 0.201934 0.201934 0.201934 2903.81 2903.81 1640.17 1.00
AIRLOOP F6 NE DXAC HEAT PUMP 0.142039 0.142039 0.142039 0.142039 1995.95 1995.95 1642.60 1.00
AIRLOOP F6 N1 DXAC HEAT PUMP 0.098978 0.098978 0.098978 0.098978 1413.58 1413.58 1136.65 1.00
AIRLOOP F6 N2 DXAC HEAT PUMP 0.097887 0.097887 0.097887 0.097887 1398.17 1398.17 1136.65 1.00
AIRLOOP F6 S1 DXAC HEAT PUMP 0.156567 0.156567 0.156567 0.156567 2282.63 2282.63 1136.65 1.00
AIRLOOP F6 S2 DXAC HEAT PUMP 0.157285 0.157285 0.157285 0.157285 2292.69 2292.69 1136.65 1.00
AIRLOOP F7 SW DXAC HEAT PUMP 0.223068 0.223068 0.223068 0.223068 3192.94 3192.94 1680.96 1.00
AIRLOOP F7 NW DXAC HEAT PUMP 0.187197 0.187197 0.187197 0.187197 2660.65 2660.65 1682.82 1.00
AIRLOOP F7 SE DXAC HEAT PUMP 0.200845 0.200845 0.200845 0.200845 2887.09 2887.09 1680.49 1.00
AIRLOOP F7 NE DXAC HEAT PUMP 0.140503 0.140503 0.140503 0.140503 1973.20 1973.20 1682.35 1.00
AIRLOOP F7 N1 DXAC HEAT PUMP 0.098182 0.098182 0.098182 0.098182 1401.45 1401.45 1136.65 1.00
AIRLOOP F7 N2 DXAC HEAT PUMP 0.097107 0.097107 0.097107 0.097107 1386.26 1386.26 1136.65 1.00
AIRLOOP F7 S1 DXAC HEAT PUMP 0.155491 0.155491 0.155491 0.155491 2266.59 2266.59 1136.65 1.00
AIRLOOP F7 S2 DXAC HEAT PUMP 0.156208 0.156208 0.156208 0.156208 2276.63 2276.63 1136.65 1.00
AIRLOOP F8 SW DXAC HEAT PUMP 0.222598 0.222598 0.222598 0.222598 3185.00 3185.00 1722.82 1.00
AIRLOOP F8 NW DXAC HEAT PUMP 0.186737 0.186737 0.186737 0.186737 2652.90 2652.90 1724.00 1.00
AIRLOOP F8 SE DXAC HEAT PUMP 0.200761 0.200761 0.200761 0.200761 2884.61 2884.61 1722.57 1.00
AIRLOOP F8 NE DXAC HEAT PUMP 0.140010 0.140010 0.140010 0.140010 1965.16 1965.16 1723.75 1.00
AIRLOOP F8 N1 DXAC HEAT PUMP 0.098397 0.098397 0.098397 0.098397 1403.70 1403.70 1136.65 1.00
AIRLOOP F8 N2 DXAC HEAT PUMP 0.097336 0.097336 0.097336 0.097336 1388.72 1388.72 1136.65 1.00
AIRLOOP F8 S1 DXAC HEAT PUMP 0.155432 0.155432 0.155432 0.155432 2264.91 2264.91 1136.65 1.00
AIRLOOP F8 S2 DXAC HEAT PUMP 0.156151 0.156151 0.156151 0.156151 2274.97 2274.97 1136.65 1.00
AIRLOOP F9 SW DXAC HEAT PUMP 0.227702 0.227702 0.227702 0.227702 3246.27 3246.27 1845.30 1.00
AIRLOOP F9 NW DXAC HEAT PUMP 0.192041 0.192041 0.192041 0.192041 2726.00 2726.00 1844.46 1.00
AIRLOOP F9 SE DXAC HEAT PUMP 0.204897 0.204897 0.204897 0.204897 2944.46 2944.46 1845.25 1.00
AIRLOOP F9 NE DXAC HEAT PUMP 0.141114 0.141114 0.141114 0.141114 1988.83 1988.83 1844.41 1.00
AIRLOOP F9 N1 DXAC HEAT PUMP 0.103573 0.103573 0.103573 0.103573 1476.09 1476.09 1208.35 1.00
AIRLOOP F9 N2 DXAC HEAT PUMP 0.102515 0.102515 0.102515 0.102515 1461.16 1461.16 1208.35 1.00
AIRLOOP F9 S1 DXAC HEAT PUMP 0.158850 0.158850 0.158850 0.158850 2311.99 2311.99 1208.90 1.00
AIRLOOP F9 S2 DXAC HEAT PUMP 0.159653 0.159653 0.159653 0.159653 2323.24 2323.24 1208.90 1.00
AIRLOOP T SW DXAC HEAT PUMP 0.283258 0.283258 0.283258 0.283258 4035.11 4035.11 2251.22 1.00
AIRLOOP T NW DXAC HEAT PUMP 0.236387 0.236387 0.236387 0.236387 3358.57 3358.57 2254.87 1.00
AIRLOOP T SE DXAC HEAT PUMP 0.256494 0.256494 0.256494 0.256494 3661.84 3661.84 2251.32 1.00
AIRLOOP T NE DXAC HEAT PUMP 0.177740 0.177740 0.177740 0.177740 2508.57 2508.57 2254.97 1.00
AIRLOOP T N1 DXAC HEAT PUMP 0.138861 0.138861 0.138861 0.138861 2034.57 2034.57 1646.47 1.00
AIRLOOP T N2 DXAC HEAT PUMP 0.138947 0.138947 0.138947 0.138947 2035.77 2035.77 1646.47 1.00
AIRLOOP T S1 DXAC HEAT PUMP 0.216094 0.216094 0.216094 0.216094 3113.02 3113.02 1639.75 1.00
AIRLOOP T S2 DXAC HEAT PUMP 0.216854 0.216854 0.216854 0.216854 3123.67 3123.67 1639.75 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
AIRLOOP G SW SUPPLY FAN 0.176890
AIRLOOP G NW SUPPLY FAN 0.146906
AIRLOOP OFFICE SUPPLY FAN 0.288783
AIRLOOP G NE SUPPLY FAN 0.104285
AIRLOOP G N1 SUPPLY FAN 0.064387
AIRLOOP G N2 SUPPLY FAN 0.063051
AIRLOOP G S1 SUPPLY FAN 0.114553
AIRLOOP G S2 SUPPLY FAN 0.120732
AIRLOOP F2 SW SUPPLY FAN 0.226007
AIRLOOP F2 NW SUPPLY FAN 0.188896
AIRLOOP F2 SE SUPPLY FAN 0.222403
AIRLOOP F2 NE SUPPLY FAN 0.141186
AIRLOOP F2 N1 SUPPLY FAN 0.093676
AIRLOOP F2 N2 SUPPLY FAN 0.092521
AIRLOOP F2 S1 SUPPLY FAN 0.152813
AIRLOOP F2 S2 SUPPLY FAN 0.155063
AIRLOOP F3 SW SUPPLY FAN 0.226977
AIRLOOP F3 NW SUPPLY FAN 0.190759
AIRLOOP F3 SE SUPPLY FAN 0.204332
AIRLOOP F3 NE SUPPLY FAN 0.143826
AIRLOOP F3 N1 SUPPLY FAN 0.097757
AIRLOOP F3 N2 SUPPLY FAN 0.096616
AIRLOOP F3 S1 SUPPLY FAN 0.156377
AIRLOOP F3 S2 SUPPLY FAN 0.157326
AIRLOOP F4 SW SUPPLY FAN 0.226718
AIRLOOP F4 NW SUPPLY FAN 0.190712
AIRLOOP F4 SE SUPPLY FAN 0.202908
AIRLOOP F4 NE SUPPLY FAN 0.143858
AIRLOOP F4 N1 SUPPLY FAN 0.099020
AIRLOOP F4 N2 SUPPLY FAN 0.097895
AIRLOOP F4 S1 SUPPLY FAN 0.157223
AIRLOOP F4 S2 SUPPLY FAN 0.157973
AIRLOOP M SW SUPPLY FAN 0.228297
AIRLOOP M NW SUPPLY FAN 0.192443
AIRLOOP M SE SUPPLY FAN 0.204988
AIRLOOP M NE SUPPLY FAN 0.145606
AIRLOOP M N1 SUPPLY FAN 0.101613
AIRLOOP M N2 SUPPLY FAN 0.100501
AIRLOOP M S1 SUPPLY FAN 0.159562
AIRLOOP M S2 SUPPLY FAN 0.160283
AIRLOOP F6 SW SUPPLY FAN 0.224629
AIRLOOP F6 NW SUPPLY FAN 0.188774
AIRLOOP F6 SE SUPPLY FAN 0.201934
AIRLOOP F6 NE SUPPLY FAN 0.142039
AIRLOOP F6 N1 SUPPLY FAN 0.098978
AIRLOOP F6 N2 SUPPLY FAN 0.097887
AIRLOOP F6 S1 SUPPLY FAN 0.156567
AIRLOOP F6 S2 SUPPLY FAN 0.157285
AIRLOOP F7 SW SUPPLY FAN 0.223068
AIRLOOP F7 NW SUPPLY FAN 0.187197
AIRLOOP F7 SE SUPPLY FAN 0.200845
AIRLOOP F7 NE SUPPLY FAN 0.140503
AIRLOOP F7 N1 SUPPLY FAN 0.098182
AIRLOOP F7 N2 SUPPLY FAN 0.097107
AIRLOOP F7 S1 SUPPLY FAN 0.155491
AIRLOOP F7 S2 SUPPLY FAN 0.156208
AIRLOOP F8 SW SUPPLY FAN 0.222598
AIRLOOP F8 NW SUPPLY FAN 0.186737
AIRLOOP F8 SE SUPPLY FAN 0.200761
AIRLOOP F8 NE SUPPLY FAN 0.140010
AIRLOOP F8 N1 SUPPLY FAN 0.098397
AIRLOOP F8 N2 SUPPLY FAN 0.097336
AIRLOOP F8 S1 SUPPLY FAN 0.155432
AIRLOOP F8 S2 SUPPLY FAN 0.156151
AIRLOOP F9 SW SUPPLY FAN 0.227702
AIRLOOP F9 NW SUPPLY FAN 0.192041
AIRLOOP F9 SE SUPPLY FAN 0.204897
AIRLOOP F9 NE SUPPLY FAN 0.141114
AIRLOOP F9 N1 SUPPLY FAN 0.103573
AIRLOOP F9 N2 SUPPLY FAN 0.102515
AIRLOOP F9 S1 SUPPLY FAN 0.158850
AIRLOOP F9 S2 SUPPLY FAN 0.159653
AIRLOOP T SW SUPPLY FAN 0.283258
AIRLOOP T NW SUPPLY FAN 0.236387
AIRLOOP T SE SUPPLY FAN 0.256494
AIRLOOP T NE SUPPLY FAN 0.177740
AIRLOOP T N1 SUPPLY FAN 0.138861
AIRLOOP T N2 SUPPLY FAN 0.138947
AIRLOOP T S1 SUPPLY FAN 0.216094
AIRLOOP T S2 SUPPLY FAN 0.216854


COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Heating Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP HEATING MODE AIRLOOP G SW 0.176890 2563.84 0.000056
HEAT PUMP HEATING MODE AIRLOOP G NW 0.146906 2112.46 0.000046
HEAT PUMP HEATING MODE AIRLOOP OFFICE 0.288783 4156.08 0.000091
HEAT PUMP HEATING MODE AIRLOOP G NE 0.104285 1477.02 0.000032
HEAT PUMP HEATING MODE AIRLOOP G N1 0.064387 931.68 0.000020
HEAT PUMP HEATING MODE AIRLOOP G N2 0.063051 912.56 0.000020
HEAT PUMP HEATING MODE AIRLOOP G S1 0.114553 1700.88 0.000037
HEAT PUMP HEATING MODE AIRLOOP G S2 0.120732 1787.39 0.000039
HEAT PUMP HEATING MODE AIRLOOP F2 SW 0.226007 3237.00 0.000071
HEAT PUMP HEATING MODE AIRLOOP F2 NW 0.188896 2695.86 0.000059
HEAT PUMP HEATING MODE AIRLOOP F2 SE 0.222403 3200.43 0.000070
HEAT PUMP HEATING MODE AIRLOOP F2 NE 0.141186 1984.64 0.000043
HEAT PUMP HEATING MODE AIRLOOP F2 N1 0.093676 1344.49 0.000029
HEAT PUMP HEATING MODE AIRLOOP F2 N2 0.092521 1328.10 0.000029
HEAT PUMP HEATING MODE AIRLOOP F2 S1 0.152813 2236.36 0.000049
HEAT PUMP HEATING MODE AIRLOOP F2 S2 0.155063 2267.91 0.000050
HEAT PUMP HEATING MODE AIRLOOP F3 SW 0.226977 3246.91 0.000071
HEAT PUMP HEATING MODE AIRLOOP F3 NW 0.190759 2718.42 0.000059
HEAT PUMP HEATING MODE AIRLOOP F3 SE 0.204332 2943.71 0.000064
HEAT PUMP HEATING MODE AIRLOOP F3 NE 0.143826 2017.99 0.000044
HEAT PUMP HEATING MODE AIRLOOP F3 N1 0.097757 1400.14 0.000031
HEAT PUMP HEATING MODE AIRLOOP F3 N2 0.096616 1383.98 0.000030
HEAT PUMP HEATING MODE AIRLOOP F3 S1 0.156377 2284.07 0.000050
HEAT PUMP HEATING MODE AIRLOOP F3 S2 0.157326 2297.37 0.000050
HEAT PUMP HEATING MODE AIRLOOP F4 SW 0.226718 3240.61 0.000071
HEAT PUMP HEATING MODE AIRLOOP F4 NW 0.190712 2715.17 0.000059
HEAT PUMP HEATING MODE AIRLOOP F4 SE 0.202908 2921.19 0.000064
HEAT PUMP HEATING MODE AIRLOOP F4 NE 0.143858 2024.77 0.000044
HEAT PUMP HEATING MODE AIRLOOP F4 N1 0.099020 1416.45 0.000031
HEAT PUMP HEATING MODE AIRLOOP F4 N2 0.097895 1400.53 0.000031
HEAT PUMP HEATING MODE AIRLOOP F4 S1 0.157223 2294.27 0.000050
HEAT PUMP HEATING MODE AIRLOOP F4 S2 0.157973 2304.78 0.000050
HEAT PUMP HEATING MODE AIRLOOP M SW 0.228297 3260.58 0.000071
HEAT PUMP HEATING MODE AIRLOOP M NW 0.192443 2737.36 0.000060
HEAT PUMP HEATING MODE AIRLOOP M SE 0.204988 2948.26 0.000064
HEAT PUMP HEATING MODE AIRLOOP M NE 0.145606 2047.31 0.000045
HEAT PUMP HEATING MODE AIRLOOP M N1 0.101613 1451.87 0.000032
HEAT PUMP HEATING MODE AIRLOOP M N2 0.100501 1436.15 0.000031
HEAT PUMP HEATING MODE AIRLOOP M S1 0.159562 2325.72 0.000051
HEAT PUMP HEATING MODE AIRLOOP M S2 0.160283 2335.83 0.000051
HEAT PUMP HEATING MODE AIRLOOP F6 SW 0.224629 3216.33 0.000070
HEAT PUMP HEATING MODE AIRLOOP F6 NW 0.188774 2684.22 0.000059
HEAT PUMP HEATING MODE AIRLOOP F6 SE 0.201934 2903.81 0.000063
HEAT PUMP HEATING MODE AIRLOOP F6 NE 0.142039 1995.95 0.000044
HEAT PUMP HEATING MODE AIRLOOP F6 N1 0.098978 1413.58 0.000031
HEAT PUMP HEATING MODE AIRLOOP F6 N2 0.097887 1398.17 0.000031
HEAT PUMP HEATING MODE AIRLOOP F6 S1 0.156567 2282.63 0.000050
HEAT PUMP HEATING MODE AIRLOOP F6 S2 0.157285 2292.69 0.000050
HEAT PUMP HEATING MODE AIRLOOP F7 SW 0.223068 3192.94 0.000070
HEAT PUMP HEATING MODE AIRLOOP F7 NW 0.187197 2660.65 0.000058
HEAT PUMP HEATING MODE AIRLOOP F7 SE 0.200845 2887.09 0.000063
HEAT PUMP HEATING MODE AIRLOOP F7 NE 0.140503 1973.20 0.000043
HEAT PUMP HEATING MODE AIRLOOP F7 N1 0.098182 1401.45 0.000031
HEAT PUMP HEATING MODE AIRLOOP F7 N2 0.097107 1386.26 0.000030
HEAT PUMP HEATING MODE AIRLOOP F7 S1 0.155491 2266.59 0.000050
HEAT PUMP HEATING MODE AIRLOOP F7 S2 0.156208 2276.63 0.000050
HEAT PUMP HEATING MODE AIRLOOP F8 SW 0.222598 3185.00 0.000070
HEAT PUMP HEATING MODE AIRLOOP F8 NW 0.186737 2652.90 0.000058
HEAT PUMP HEATING MODE AIRLOOP F8 SE 0.200761 2884.61 0.000063
HEAT PUMP HEATING MODE AIRLOOP F8 NE 0.140010 1965.16 0.000043
HEAT PUMP HEATING MODE AIRLOOP F8 N1 0.098397 1403.70 0.000031
HEAT PUMP HEATING MODE AIRLOOP F8 N2 0.097336 1388.72 0.000030
HEAT PUMP HEATING MODE AIRLOOP F8 S1 0.155432 2264.91 0.000049
HEAT PUMP HEATING MODE AIRLOOP F8 S2 0.156151 2274.97 0.000050
HEAT PUMP HEATING MODE AIRLOOP F9 SW 0.227702 3246.27 0.000071
HEAT PUMP HEATING MODE AIRLOOP F9 NW 0.192041 2726.00 0.000060
HEAT PUMP HEATING MODE AIRLOOP F9 SE 0.204897 2944.46 0.000064
HEAT PUMP HEATING MODE AIRLOOP F9 NE 0.141114 1988.83 0.000043
HEAT PUMP HEATING MODE AIRLOOP F9 N1 0.103573 1476.09 0.000032
HEAT PUMP HEATING MODE AIRLOOP F9 N2 0.102515 1461.16 0.000032
HEAT PUMP HEATING MODE AIRLOOP F9 S1 0.158850 2311.99 0.000051
HEAT PUMP HEATING MODE AIRLOOP F9 S2 0.159653 2323.24 0.000051
HEAT PUMP HEATING MODE AIRLOOP T SW 0.283258 4035.11 0.000088
HEAT PUMP HEATING MODE AIRLOOP T NW 0.236387 3358.57 0.000073
HEAT PUMP HEATING MODE AIRLOOP T SE 0.256494 3661.84 0.000080
HEAT PUMP HEATING MODE AIRLOOP T NE 0.177740 2508.57 0.000055
HEAT PUMP HEATING MODE AIRLOOP T N1 0.138861 2034.57 0.000044
HEAT PUMP HEATING MODE AIRLOOP T N2 0.138947 2035.77 0.000044
HEAT PUMP HEATING MODE AIRLOOP T S1 0.216094 3113.02 0.000068
HEAT PUMP HEATING MODE AIRLOOP T S2 0.216854 3123.67 0.000068


Coil:Heating:Electric

Nominal Capacity [W]
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW 1666.56
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW 1672.45
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE 2242.41
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE 1670.56
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 1238.05
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 1238.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 1227.96
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 1234.08
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW 1572.32
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW 1576.60
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE 1589.50
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE 1574.69
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW 1553.36
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW 1556.84
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE 1554.12
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE 1555.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW 1574.01
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW 1577.31
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE 1573.04
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE 1576.07
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW 1578.67
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW 1580.66
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE 1577.75
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE 1579.71
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW 1640.86
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW 1643.30
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE 1640.17
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE 1642.60
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW 1680.96
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW 1682.82
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE 1680.49
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE 1682.35
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW 1722.82
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW 1724.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE 1722.57
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE 1723.75
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 1136.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW 1845.30
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW 1844.46
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE 1845.25
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE 1844.41
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 1208.35
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 1208.35
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 1208.90
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 1208.90
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW 2251.22
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW 2254.87
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE 2251.32
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE 2254.97
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 1646.47
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 1646.47
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 1639.75
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 1639.75


PlantLoop

Maximum Loop Flow Rate [m3/s] Plant Loop Volume [m3]
SHWSYS1 0.000289 0.325214
SINGLE WATER PLANT LOOP 0.004056 4.56


Boiler:HotWater

Design Water Flow Rate [m3/s]
CENTRAL BOILER 0.004056


WaterHeater:Mixed

Use Side Design Flow Rate [m3/s]
SHWSYS1 WATER HEATER 0.000289


EvaporativeFluidCooler:SingleSpeed

Design Water Flow Rate [m3/s] Fan Power at Design Air Flow Rate [W] Design Air Flow Rate [m3/s] U-Factor Times Area Value at Design Air Flow Rate [W/C]
CENTRAL TOWER 0.004056 1958.18 5.15 6075.76


Pump:ConstantSpeed

Rated Flow Rate [m3/s] Rated Power Consumption [W]
SHWSYS1 PUMP 0.000289 36.93
PLANT CIRC PUMP 0.004056 1295.38



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:07

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW3 |
G WWALL SWA GWINDOW2 |
G NWALL NWA GWINDOW4 |
G WWALL NWA GWINDOW6 |
G SWALL SEA GWINDOW1 |
G EWALL SEA GWINDOW8 |
G NWALL NEA GWINDOW5 |
G EWALL NEA GWINDOW7 |
G NWALL N1A GWINDOW9 |
G NWALL N2A GWINDOW10 |
G SWALL S1A GWINDOW11 |
G SWALL S2A GWINDOW12 |
G WWALL C GWINDOW13 |
G EWALL C ENTRANCE DOOR |
F2 WWALL SWA F2WINDOW2 |
F2 SWALL SWA F2WINDOW3 |
F2 NWALL NWA F2WINDOW4 |
F2 WWALL NWA F2WINDOW6 |
F2 EWALL SEA F2WINDOW8 |
F2 SWALL SEA F2WINDOW1 |
F2 NWALL NEA F2WINDOW5 |
F2 EWALL NEA F2WINDOW7 |
F2 NWALL N1A F2WINDOW9 |
F2 NWALL N2A F2WINDOW10 |
F2 SWALL S1A F2WINDOW11 |
F2 SWALL S2A F2WINDOW12 |
F2 WWALL C F2WINDOW13 |
F2 EWALL C F2WINDOW14 |
F3 WWALL SWA F3WINDOW2 |
F3 SWALL SWA F3WINDOW3 |
F3 NWALL NWA F3WINDOW4 |
F3 WWALL NWA F3WINDOW6 |
F3 EWALL SEA F3WINDOW8 |
F3 SWALL SEA F3WINDOW1 |
F3 NWALL NEA F3WINDOW5 |
F3 EWALL NEA F3WINDOW7 |
F3 NWALL N1A F3WINDOW9 |
F3 NWALL N2A F3WINDOW10 |
F3 SWALL S1A F3WINDOW11 |
F3 SWALL S2A F3WINDOW12 |
F3 WWALL C F3WINDOW13 |
F3 EWALL C F3WINDOW14 |
F4 WWALL SWA F4WINDOW2 |
F4 SWALL SWA F4WINDOW3 |
F4 NWALL NWA F4WINDOW4 |
F4 WWALL NWA F4WINDOW6 |
F4 EWALL SEA F4WINDOW8 |
F4 SWALL SEA F4WINDOW1 |
F4 NWALL NEA F4WINDOW5 |
F4 EWALL NEA F4WINDOW7 |
F4 NWALL N1A F4WINDOW9 |
F4 NWALL N2A F4WINDOW10 |
F4 SWALL S1A F4WINDOW11 |
F4 SWALL S2A F4WINDOW12 |
F4 WWALL C F4WINDOW13 |
F4 EWALL C F4WINDOW14 |
M WWALL SWA MWINDOW2 |
M SWALL SWA MWINDOW3 |
M NWALL NWA MWINDOW4 |
M WWALL NWA MWINDOW6 |
M EWALL SEA MWINDOW8 |
M SWALL SEA MWINDOW1 |
M NWALL NEA MWINDOW5 |
M EWALL NEA MWINDOW7 |
M NWALL N1A MWINDOW9 |
M NWALL N2A MWINDOW10 |
M SWALL S1A MWINDOW11 |
M SWALL S2A MWINDOW12 |
M WWALL C MWINDOW13 |
M EWALL C MWINDOW14 |
F6 WWALL SWA F6WINDOW2 |
F6 SWALL SWA F6WINDOW3 |
F6 NWALL NWA F6WINDOW4 |
F6 WWALL NWA F6WINDOW6 |
F6 EWALL SEA F6WINDOW8 |
F6 SWALL SEA F6WINDOW1 |
F6 NWALL NEA F6WINDOW5 |
F6 EWALL NEA F6WINDOW7 |
F6 NWALL N1A F6WINDOW9 |
F6 NWALL N2A F6WINDOW10 |
F6 SWALL S1A F6WINDOW11 |
F6 SWALL S2A F6WINDOW12 |
F6 WWALL C F6WINDOW13 |
F6 EWALL C F6WINDOW14 |
F7 WWALL SWA F7WINDOW2 |
F7 SWALL SWA F7WINDOW3 |
F7 NWALL NWA F7WINDOW4 |
F7 WWALL NWA F7WINDOW6 |
F7 EWALL SEA F7WINDOW8 |
F7 SWALL SEA F7WINDOW1 |
F7 NWALL NEA F7WINDOW5 |
F7 EWALL NEA F7WINDOW7 |
F7 NWALL N1A F7WINDOW9 |
F7 NWALL N2A F7WINDOW10 |
F7 SWALL S1A F7WINDOW11 |
F7 SWALL S2A F7WINDOW12 |
F7 WWALL C F7WINDOW13 |
F7 EWALL C F7WINDOW14 |
F8 WWALL SWA F8WINDOW2 |
F8 SWALL SWA F8WINDOW3 |
F8 NWALL NWA F8WINDOW4 |
F8 WWALL NWA F8WINDOW6 |
F8 EWALL SEA F8WINDOW8 |
F8 SWALL SEA F8WINDOW1 |
F8 NWALL NEA F8WINDOW5 |
F8 EWALL NEA F8WINDOW7 |
F8 NWALL N1A F8WINDOW9 |
F8 NWALL N2A F8WINDOW10 |
F8 SWALL S1A F8WINDOW11 |
F8 SWALL S2A F8WINDOW12 |
F8 WWALL C F8WINDOW13 |
F8 EWALL C F8WINDOW14 |
F9 WWALL SWA F9WINDOW2 |
F9 SWALL SWA F9WINDOW3 |
F9 NWALL NWA F9WINDOW4 |
F9 WWALL NWA F9WINDOW6 |
F9 EWALL SEA F9WINDOW8 |
F9 SWALL SEA F9WINDOW1 |
F9 NWALL NEA F9WINDOW5 |
F9 EWALL NEA F9WINDOW7 |
F9 NWALL N1A F9WINDOW9 |
F9 NWALL N2A F9WINDOW10 |
F9 SWALL S1A F9WINDOW11 |
F9 SWALL S2A F9WINDOW12 |
F9 WWALL C F9WINDOW13 |
F9 EWALL C F9WINDOW14 |
T WWALL SWA TWINDOW2 |
T SWALL SWA TWINDOW3 |
T NWALL NWA TWINDOW4 |
T WWALL NWA TWINDOW6 |
T EWALL SEA TWINDOW8 |
T SWALL SEA TWINDOW1 |
T NWALL NEA TWINDOW5 |
T EWALL NEA TWINDOW7 |
T NWALL N1A TWINDOW9 |
T NWALL N2A TWINDOW10 |
T SWALL S1A TWINDOW11 |
T SWALL S2A TWINDOW12 |
T WWALL C TWINDOW13 |
T EWALL C TWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:07

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.10 9.60
February 22.45 11.29
March 22.49 12.66
April 22.40 13.68
May 22.37 15.00
June 22.91 15.34
July 23.22 15.94
August 23.51 16.62
September 23.68 16.72
October 22.92 15.11
November 22.68 12.79
December 22.45 10.66
     
Annual Sum or Average 22.77 13.79
Minimum of Months 22.10 9.60
Maximum of Months 23.68 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 9.60
February 21.80 11.29
March 21.92 12.66
April 22.07 13.68
May 22.22 15.00
June 22.81 15.34
July 23.04 15.94
August 23.20 16.62
September 23.14 16.72
October 22.25 15.11
November 21.92 12.79
December 21.75 10.66
     
Annual Sum or Average 22.32 13.79
Minimum of Months 21.71 9.60
Maximum of Months 23.20 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.48 9.60
February 22.81 11.29
March 22.99 12.66
April 23.04 13.68
May 23.17 15.00
June 23.58 15.34
July 23.91 15.94
August 24.06 16.62
September 24.14 16.72
October 23.52 15.11
November 23.10 12.79
December 22.72 10.66
     
Annual Sum or Average 23.29 13.79
Minimum of Months 22.48 9.60
Maximum of Months 24.14 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 9.60
February 21.76 11.29
March 21.89 12.66
April 22.04 13.68
May 22.17 15.00
June 22.68 15.34
July 22.83 15.94
August 23.05 16.62
September 22.97 16.72
October 22.19 15.11
November 21.88 12.79
December 21.71 10.66
     
Annual Sum or Average 22.24 13.79
Minimum of Months 21.70 9.60
Maximum of Months 23.05 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 9.60
February 21.74 11.29
March 21.82 12.66
April 21.93 13.68
May 22.06 15.00
June 22.63 15.34
July 22.75 15.94
August 22.98 16.62
September 22.93 16.72
October 22.16 15.11
November 21.87 12.79
December 21.72 10.66
     
Annual Sum or Average 22.19 13.79
Minimum of Months 21.70 9.60
Maximum of Months 22.98 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 9.60
February 21.73 11.29
March 21.82 12.66
April 21.93 13.68
May 22.06 15.00
June 22.62 15.34
July 22.74 15.94
August 22.97 16.62
September 22.91 16.72
October 22.16 15.11
November 21.87 12.79
December 21.72 10.66
     
Annual Sum or Average 22.19 13.79
Minimum of Months 21.70 9.60
Maximum of Months 22.97 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.22 9.60
February 22.57 11.29
March 22.54 12.66
April 22.35 13.68
May 22.28 15.00
June 22.86 15.34
July 23.08 15.94
August 23.47 16.62
September 23.70 16.72
October 23.01 15.11
November 22.87 12.79
December 22.63 10.66
     
Annual Sum or Average 22.80 13.79
Minimum of Months 22.22 9.60
Maximum of Months 23.70 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.27 9.60
February 22.64 11.29
March 22.61 12.66
April 22.42 13.68
May 22.34 15.00
June 22.93 15.34
July 23.15 15.94
August 23.53 16.62
September 23.75 16.72
October 23.08 15.11
November 22.95 12.79
December 22.69 10.66
     
Annual Sum or Average 22.86 13.79
Minimum of Months 22.27 9.60
Maximum of Months 23.75 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 18.51 9.60
February 19.35 11.29
March 19.90 12.66
April 20.30 13.68
May 20.82 15.00
June 21.73 15.34
July 22.04 15.94
August 22.42 16.62
September 22.45 16.72
October 21.04 15.11
November 19.95 12.79
December 19.02 10.66
     
Annual Sum or Average 20.63 13.79
Minimum of Months 18.51 9.60
Maximum of Months 22.45 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SW APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.60 9.60
February 23.24 11.29
March 23.29 12.66
April 23.03 13.68
May 22.90 15.00
June 23.12 15.34
July 23.46 15.94
August 23.80 16.62
September 23.99 16.72
October 23.67 15.11
November 23.56 12.79
December 23.19 10.66
     
Annual Sum or Average 23.32 13.79
Minimum of Months 22.60 9.60
Maximum of Months 23.99 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NW APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.79 9.60
February 21.99 11.29
March 22.24 12.66
April 22.45 13.68
May 22.61 15.00
June 22.94 15.34
July 23.19 15.94
August 23.37 16.62
September 23.30 16.72
October 22.68 15.11
November 22.37 12.79
December 21.93 10.66
     
Annual Sum or Average 22.58 13.79
Minimum of Months 21.79 9.60
Maximum of Months 23.37 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SE APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.78 9.60
February 23.39 11.29
March 23.44 12.66
April 23.23 13.68
May 23.09 15.00
June 23.31 15.34
July 23.55 15.94
August 23.88 16.62
September 24.04 16.72
October 23.78 15.11
November 23.71 12.79
December 23.35 10.66
     
Annual Sum or Average 23.46 13.79
Minimum of Months 22.78 9.60
Maximum of Months 24.04 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NE APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.75 9.60
February 21.91 11.29
March 22.15 12.66
April 22.37 13.68
May 22.52 15.00
June 22.81 15.34
July 22.95 15.94
August 23.20 16.62
September 23.10 16.72
October 22.58 15.11
November 22.27 12.79
December 21.84 10.66
     
Annual Sum or Average 22.46 13.79
Minimum of Months 21.75 9.60
Maximum of Months 23.20 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N1 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.81 9.60
February 21.97 11.29
March 22.18 12.66
April 22.36 13.68
May 22.47 15.00
June 22.79 15.34
July 22.89 15.94
August 23.15 16.62
September 23.09 16.72
October 22.64 15.11
November 22.42 12.79
December 21.94 10.66
     
Annual Sum or Average 22.48 13.79
Minimum of Months 21.81 9.60
Maximum of Months 23.15 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N2 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.81 9.60
February 21.96 11.29
March 22.17 12.66
April 22.35 13.68
May 22.46 15.00
June 22.78 15.34
July 22.87 15.94
August 23.13 16.62
September 23.07 16.72
October 22.63 15.11
November 22.41 12.79
December 21.94 10.66
     
Annual Sum or Average 22.47 13.79
Minimum of Months 21.81 9.60
Maximum of Months 23.13 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S1 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.03 9.60
February 23.59 11.29
March 23.50 12.66
April 23.11 13.68
May 22.85 15.00
June 23.06 15.34
July 23.28 15.94
August 23.73 16.62
September 23.98 16.72
October 23.79 15.11
November 23.83 12.79
December 23.58 10.66
     
Annual Sum or Average 23.44 13.79
Minimum of Months 22.85 9.60
Maximum of Months 23.98 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S2 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.06 9.60
February 23.62 11.29
March 23.52 12.66
April 23.15 13.68
May 22.88 15.00
June 23.09 15.34
July 23.31 15.94
August 23.75 16.62
September 23.99 16.72
October 23.81 15.11
November 23.85 12.79
December 23.61 10.66
     
Annual Sum or Average 23.47 13.79
Minimum of Months 22.88 9.60
Maximum of Months 23.99 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 CORRIDOR

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.71 9.60
February 23.28 11.29
March 23.53 12.66
April 23.61 13.68
May 23.70 15.00
June 24.08 15.34
July 24.40 15.94
August 24.71 16.62
September 24.79 16.72
October 24.13 15.11
November 23.70 12.79
December 23.12 10.66
     
Annual Sum or Average 23.82 13.79
Minimum of Months 22.71 9.60
Maximum of Months 24.79 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SW APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.75 9.60
February 23.41 11.29
March 23.42 12.66
April 23.10 13.68
May 22.92 15.00
June 22.99 15.34
July 23.33 15.94
August 23.72 16.62
September 23.93 16.72
October 23.73 15.11
November 23.72 12.79
December 23.37 10.66
     
Annual Sum or Average 23.36 13.79
Minimum of Months 22.75 9.60
Maximum of Months 23.93 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NW APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.82 9.60
February 22.05 11.29
March 22.32 12.66
April 22.50 13.68
May 22.63 15.00
June 22.82 15.34
July 23.04 15.94
August 23.28 16.62
September 23.20 16.72
October 22.75 15.11
November 22.56 12.79
December 22.01 10.66
     
Annual Sum or Average 22.59 13.79
Minimum of Months 21.82 9.60
Maximum of Months 23.28 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SE APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.75 9.60
February 23.39 11.29
March 23.39 12.66
April 23.10 13.68
May 22.93 15.00
June 22.99 15.34
July 23.23 15.94
August 23.65 16.62
September 23.87 16.72
October 23.69 15.11
November 23.72 12.79
December 23.37 10.66
     
Annual Sum or Average 23.34 13.79
Minimum of Months 22.75 9.60
Maximum of Months 23.87 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NE APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.78 9.60
February 21.96 11.29
March 22.23 12.66
April 22.43 13.68
May 22.55 15.00
June 22.72 15.34
July 22.83 15.94
August 23.12 16.62
September 23.02 16.72
October 22.66 15.11
November 22.44 12.79
December 21.90 10.66
     
Annual Sum or Average 22.47 13.79
Minimum of Months 21.78 9.60
Maximum of Months 23.12 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N1 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.88 9.60
February 22.09 11.29
March 22.33 12.66
April 22.49 13.68
May 22.56 15.00
June 22.73 15.34
July 22.81 15.94
August 23.10 16.62
September 23.04 16.72
October 22.78 15.11
November 22.69 12.79
December 22.08 10.66
     
Annual Sum or Average 22.55 13.79
Minimum of Months 21.88 9.60
Maximum of Months 23.10 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N2 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.88 9.60
February 22.08 11.29
March 22.32 12.66
April 22.48 13.68
May 22.55 15.00
June 22.72 15.34
July 22.79 15.94
August 23.08 16.62
September 23.02 16.72
October 22.77 15.11
November 22.68 12.79
December 22.07 10.66
     
Annual Sum or Average 22.54 13.79
Minimum of Months 21.88 9.60
Maximum of Months 23.08 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S1 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.29 9.60
February 23.84 11.29
March 23.71 12.66
April 23.28 13.68
May 22.95 15.00
June 22.99 15.34
July 23.20 15.94
August 23.69 16.62
September 23.95 16.72
October 23.89 15.11
November 24.02 12.79
December 23.82 10.66
     
Annual Sum or Average 23.55 13.79
Minimum of Months 22.95 9.60
Maximum of Months 24.02 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S2 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.30 9.60
February 23.85 11.29
March 23.71 12.66
April 23.29 13.68
May 22.96 15.00
June 23.00 15.34
July 23.20 15.94
August 23.69 16.62
September 23.95 16.72
October 23.89 15.11
November 24.03 12.79
December 23.82 10.66
     
Annual Sum or Average 23.55 13.79
Minimum of Months 22.96 9.60
Maximum of Months 24.03 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 CORRIDOR

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.18 9.60
February 23.75 11.29
March 23.97 12.66
April 23.98 13.68
May 23.99 15.00
June 24.15 15.34
July 24.44 15.94
August 24.81 16.62
September 24.90 16.72
October 24.49 15.11
November 24.22 12.79
December 23.61 10.66
     
Annual Sum or Average 24.12 13.79
Minimum of Months 23.18 9.60
Maximum of Months 24.90 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SW APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.75 9.60
February 23.41 11.29
March 23.42 12.66
April 23.11 13.68
May 22.86 15.00
June 22.88 15.34
July 23.20 15.94
August 23.66 16.62
September 23.89 16.72
October 23.71 15.11
November 23.78 12.79
December 23.38 10.66
     
Annual Sum or Average 23.34 13.79
Minimum of Months 22.75 9.60
Maximum of Months 23.89 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NW APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.83 9.60
February 22.05 11.29
March 22.33 12.66
April 22.51 13.68
May 22.59 15.00
June 22.72 15.34
July 22.92 15.94
August 23.22 16.62
September 23.14 16.72
October 22.76 15.11
November 22.68 12.79
December 22.03 10.66
     
Annual Sum or Average 22.57 13.79
Minimum of Months 21.83 9.60
Maximum of Months 23.22 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SE APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.71 9.60
February 23.34 11.29
March 23.35 12.66
April 23.06 13.68
May 22.84 15.00
June 22.85 15.34
July 23.07 15.94
August 23.56 16.62
September 23.81 16.72
October 23.64 15.11
November 23.74 12.79
December 23.35 10.66
     
Annual Sum or Average 23.28 13.79
Minimum of Months 22.71 9.60
Maximum of Months 23.81 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NE APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.78 9.60
February 21.96 11.29
March 22.24 12.66
April 22.44 13.68
May 22.53 15.00
June 22.65 15.34
July 22.73 15.94
August 23.07 16.62
September 22.97 16.72
October 22.67 15.11
November 22.56 12.79
December 21.92 10.66
     
Annual Sum or Average 22.46 13.79
Minimum of Months 21.78 9.60
Maximum of Months 23.07 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N1 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.90 9.60
February 22.12 11.29
March 22.38 12.66
April 22.54 13.68
May 22.57 15.00
June 22.68 15.34
July 22.74 15.94
August 23.08 16.62
September 23.03 16.72
October 22.83 15.11
November 22.86 12.79
December 22.13 10.66
     
Annual Sum or Average 22.57 13.79
Minimum of Months 21.90 9.60
Maximum of Months 23.08 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N2 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.90 9.60
February 22.11 11.29
March 22.37 12.66
April 22.53 13.68
May 22.56 15.00
June 22.67 15.34
July 22.72 15.94
August 23.06 16.62
September 23.01 16.72
October 22.82 15.11
November 22.85 12.79
December 22.12 10.66
     
Annual Sum or Average 22.56 13.79
Minimum of Months 21.90 9.60
Maximum of Months 23.06 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S1 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.33 9.60
February 23.89 11.29
March 23.75 12.66
April 23.35 13.68
May 22.95 15.00
June 22.92 15.34
July 23.12 15.94
August 23.67 16.62
September 23.94 16.72
October 23.91 15.11
November 24.10 12.79
December 23.86 10.66
     
Annual Sum or Average 23.56 13.79
Minimum of Months 22.92 9.60
Maximum of Months 24.10 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S2 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.33 9.60
February 23.88 11.29
March 23.75 12.66
April 23.35 13.68
May 22.95 15.00
June 22.93 15.34
July 23.11 15.94
August 23.66 16.62
September 23.93 16.72
October 23.90 15.11
November 24.10 12.79
December 23.86 10.66
     
Annual Sum or Average 23.56 13.79
Minimum of Months 22.93 9.60
Maximum of Months 24.10 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 CORRIDOR

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.33 9.60
February 23.90 11.29
March 24.10 12.66
April 24.10 13.68
May 24.06 15.00
June 24.14 15.34
July 24.42 15.94
August 24.83 16.62
September 24.94 16.72
October 24.60 15.11
November 24.43 12.79
December 23.78 10.66
     
Annual Sum or Average 24.22 13.79
Minimum of Months 23.33 9.60
Maximum of Months 24.94 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.72 9.60
February 23.37 11.29
March 23.37 12.66
April 23.03 13.68
May 22.78 15.00
June 22.78 15.34
July 23.08 15.94
August 23.57 16.62
September 23.82 16.72
October 23.65 15.11
November 23.77 12.79
December 23.37 10.66
     
Annual Sum or Average 23.27 13.79
Minimum of Months 22.72 9.60
Maximum of Months 23.82 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.83 9.60
February 22.04 11.29
March 22.30 12.66
April 22.47 13.68
May 22.54 15.00
June 22.65 15.34
July 22.81 15.94
August 23.14 16.62
September 23.07 16.72
October 22.73 15.11
November 22.70 12.79
December 22.04 10.66
     
Annual Sum or Average 22.53 13.79
Minimum of Months 21.83 9.60
Maximum of Months 23.14 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.69 9.60
February 23.29 11.29
March 23.29 12.66
April 22.99 13.68
May 22.76 15.00
June 22.76 15.34
July 22.96 15.94
August 23.48 16.62
September 23.73 16.72
October 23.58 15.11
November 23.72 12.79
December 23.32 10.66
     
Annual Sum or Average 23.21 13.79
Minimum of Months 22.69 9.60
Maximum of Months 23.73 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.79 9.60
February 21.96 11.29
March 22.22 12.66
April 22.41 13.68
May 22.48 15.00
June 22.59 15.34
July 22.64 15.94
August 23.01 16.62
September 22.90 16.72
October 22.65 15.11
November 22.59 12.79
December 21.93 10.66
     
Annual Sum or Average 22.43 13.79
Minimum of Months 21.79 9.60
Maximum of Months 23.01 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.92 9.60
February 22.14 11.29
March 22.38 12.66
April 22.53 13.68
May 22.54 15.00
June 22.63 15.34
July 22.68 15.94
August 23.04 16.62
September 22.99 16.72
October 22.83 15.11
November 22.92 12.79
December 22.16 10.66
     
Annual Sum or Average 22.56 13.79
Minimum of Months 21.92 9.60
Maximum of Months 23.04 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.92 9.60
February 22.13 11.29
March 22.37 12.66
April 22.52 13.68
May 22.53 15.00
June 22.63 15.34
July 22.66 15.94
August 23.02 16.62
September 22.97 16.72
October 22.82 15.11
November 22.91 12.79
December 22.15 10.66
     
Annual Sum or Average 22.55 13.79
Minimum of Months 21.92 9.60
Maximum of Months 23.02 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.33 9.60
February 23.88 11.29
March 23.73 12.66
April 23.31 13.68
May 22.90 15.00
June 22.86 15.34
July 23.04 15.94
August 23.60 16.62
September 23.89 16.72
October 23.87 15.11
November 24.11 12.79
December 23.87 10.66
     
Annual Sum or Average 23.53 13.79
Minimum of Months 22.86 9.60
Maximum of Months 24.11 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.33 9.60
February 23.88 11.29
March 23.72 12.66
April 23.31 13.68
May 22.90 15.00
June 22.86 15.34
July 23.03 15.94
August 23.59 16.62
September 23.88 16.72
October 23.87 15.11
November 24.11 12.79
December 23.87 10.66
     
Annual Sum or Average 23.53 13.79
Minimum of Months 22.86 9.60
Maximum of Months 24.11 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.90 9.60
February 24.45 11.29
March 24.64 12.66
April 24.61 13.68
May 24.56 15.00
June 24.61 15.34
July 24.86 15.94
August 25.30 16.62
September 25.41 16.72
October 25.13 15.11
November 25.02 12.79
December 24.35 10.66
     
Annual Sum or Average 24.74 13.79
Minimum of Months 23.90 9.60
Maximum of Months 25.41 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SW APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.60 9.60
February 23.21 11.29
March 23.22 12.66
April 22.86 13.68
May 22.63 15.00
June 22.63 15.34
July 22.89 15.94
August 23.41 16.62
September 23.67 16.72
October 23.50 15.11
November 23.66 12.79
December 23.26 10.66
     
Annual Sum or Average 23.13 13.79
Minimum of Months 22.60 9.60
Maximum of Months 23.67 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NW APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.80 9.60
February 21.96 11.29
March 22.18 12.66
April 22.34 13.68
May 22.41 15.00
June 22.51 15.34
July 22.64 15.94
August 22.99 16.62
September 22.90 16.72
October 22.60 15.11
November 22.59 12.79
December 21.97 10.66
     
Annual Sum or Average 22.41 13.79
Minimum of Months 21.80 9.60
Maximum of Months 22.99 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SE APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.57 9.60
February 23.14 11.29
March 23.14 12.66
April 22.83 13.68
May 22.62 15.00
June 22.63 15.34
July 22.79 15.94
August 23.32 16.62
September 23.58 16.72
October 23.43 15.11
November 23.61 12.79
December 23.21 10.66
     
Annual Sum or Average 23.07 13.79
Minimum of Months 22.57 9.60
Maximum of Months 23.61 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NE APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.77 9.60
February 21.90 11.29
March 22.12 12.66
April 22.31 13.68
May 22.37 15.00
June 22.48 15.34
July 22.49 15.94
August 22.86 16.62
September 22.75 16.72
October 22.53 15.11
November 22.48 12.79
December 21.88 10.66
     
Annual Sum or Average 22.33 13.79
Minimum of Months 21.77 9.60
Maximum of Months 22.86 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N1 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.87 9.60
February 22.04 11.29
March 22.26 12.66
April 22.41 13.68
May 22.43 15.00
June 22.51 15.34
July 22.53 15.94
August 22.89 16.62
September 22.84 16.72
October 22.70 15.11
November 22.80 12.79
December 22.07 10.66
     
Annual Sum or Average 22.45 13.79
Minimum of Months 21.87 9.60
Maximum of Months 22.89 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N2 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.86 9.60
February 22.03 11.29
March 22.25 12.66
April 22.40 13.68
May 22.42 15.00
June 22.50 15.34
July 22.52 15.94
August 22.88 16.62
September 22.83 16.72
October 22.70 15.11
November 22.78 12.79
December 22.06 10.66
     
Annual Sum or Average 22.44 13.79
Minimum of Months 21.86 9.60
Maximum of Months 22.88 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S1 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.20 9.60
February 23.77 11.29
March 23.60 12.66
April 23.14 13.68
May 22.75 15.00
June 22.71 15.34
July 22.87 15.94
August 23.45 16.62
September 23.77 16.72
October 23.75 15.11
November 24.04 12.79
December 23.78 10.66
     
Annual Sum or Average 23.40 13.79
Minimum of Months 22.71 9.60
Maximum of Months 24.04 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S2 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.20 9.60
February 23.76 11.29
March 23.59 12.66
April 23.14 13.68
May 22.75 15.00
June 22.71 15.34
July 22.86 15.94
August 23.44 16.62
September 23.76 16.72
October 23.75 15.11
November 24.04 12.79
December 23.78 10.66
     
Annual Sum or Average 23.40 13.79
Minimum of Months 22.71 9.60
Maximum of Months 24.04 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 CORRIDOR

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.25 9.60
February 23.79 11.29
March 23.96 12.66
April 23.92 13.68
May 23.88 15.00
June 23.93 15.34
July 24.16 15.94
August 24.61 16.62
September 24.73 16.72
October 24.45 15.11
November 24.36 12.79
December 23.70 10.66
     
Annual Sum or Average 24.06 13.79
Minimum of Months 23.25 9.60
Maximum of Months 24.73 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SW APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.51 9.60
February 23.08 11.29
March 23.10 12.66
April 22.73 13.68
May 22.53 15.00
June 22.55 15.34
July 22.75 15.94
August 23.28 16.62
September 23.55 16.72
October 23.37 15.11
November 23.56 12.79
December 23.16 10.66
     
Annual Sum or Average 23.01 13.79
Minimum of Months 22.51 9.60
Maximum of Months 23.56 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NW APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.78 9.60
February 21.92 11.29
March 22.11 12.66
April 22.26 13.68
May 22.33 15.00
June 22.44 15.34
July 22.51 15.94
August 22.87 16.62
September 22.79 16.72
October 22.50 15.11
November 22.50 12.79
December 21.93 10.66
     
Annual Sum or Average 22.33 13.79
Minimum of Months 21.78 9.60
Maximum of Months 22.87 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SE APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.49 9.60
February 23.01 11.29
March 23.02 12.66
April 22.71 13.68
May 22.53 15.00
June 22.55 15.34
July 22.66 15.94
August 23.21 16.62
September 23.47 16.72
October 23.31 15.11
November 23.52 12.79
December 23.11 10.66
     
Annual Sum or Average 22.96 13.79
Minimum of Months 22.49 9.60
Maximum of Months 23.52 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NE APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.75 9.60
February 21.87 11.29
March 22.06 12.66
April 22.24 13.68
May 22.30 15.00
June 22.42 15.34
July 22.38 15.94
August 22.76 16.62
September 22.65 16.72
October 22.45 15.11
November 22.39 12.79
December 21.84 10.66
     
Annual Sum or Average 22.26 13.79
Minimum of Months 21.75 9.60
Maximum of Months 22.76 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N1 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.83 9.60
February 21.97 11.29
March 22.18 12.66
April 22.32 13.68
May 22.35 15.00
June 22.44 15.34
July 22.43 15.94
August 22.79 16.62
September 22.75 16.72
October 22.61 15.11
November 22.69 12.79
December 22.02 10.66
     
Annual Sum or Average 22.37 13.79
Minimum of Months 21.83 9.60
Maximum of Months 22.79 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N2 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.83 9.60
February 21.97 11.29
March 22.18 12.66
April 22.32 13.68
May 22.35 15.00
June 22.44 15.34
July 22.42 15.94
August 22.78 16.62
September 22.73 16.72
October 22.61 15.11
November 22.68 12.79
December 22.01 10.66
     
Annual Sum or Average 22.36 13.79
Minimum of Months 21.83 9.60
Maximum of Months 22.78 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S1 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.09 9.60
February 23.66 11.29
March 23.49 12.66
April 23.00 13.68
May 22.65 15.00
June 22.63 15.34
July 22.75 15.94
August 23.33 16.62
September 23.66 16.72
October 23.65 15.11
November 23.97 12.79
December 23.70 10.66
     
Annual Sum or Average 23.30 13.79
Minimum of Months 22.63 9.60
Maximum of Months 23.97 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S2 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.09 9.60
February 23.66 11.29
March 23.48 12.66
April 23.00 13.68
May 22.65 15.00
June 22.63 15.34
July 22.74 15.94
August 23.33 16.62
September 23.66 16.72
October 23.65 15.11
November 23.97 12.79
December 23.70 10.66
     
Annual Sum or Average 23.29 13.79
Minimum of Months 22.63 9.60
Maximum of Months 23.97 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 CORRIDOR

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.08 9.60
February 23.60 11.29
March 23.77 12.66
April 23.72 13.68
May 23.70 15.00
June 23.75 15.34
July 23.96 15.94
August 24.41 16.62
September 24.53 16.72
October 24.26 15.11
November 24.18 12.79
December 23.54 10.66
     
Annual Sum or Average 23.87 13.79
Minimum of Months 23.08 9.60
Maximum of Months 24.53 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SW APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.44 9.60
February 22.96 11.29
March 22.98 12.66
April 22.63 13.68
May 22.46 15.00
June 22.48 15.34
July 22.65 15.94
August 23.18 16.62
September 23.45 16.72
October 23.26 15.11
November 23.47 12.79
December 23.07 10.66
     
Annual Sum or Average 22.92 13.79
Minimum of Months 22.44 9.60
Maximum of Months 23.47 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NW APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.77 9.60
February 21.88 11.29
March 22.06 12.66
April 22.21 13.68
May 22.28 15.00
June 22.39 15.34
July 22.42 15.94
August 22.79 16.62
September 22.70 16.72
October 22.44 15.11
November 22.42 12.79
December 21.90 10.66
     
Annual Sum or Average 22.27 13.79
Minimum of Months 21.77 9.60
Maximum of Months 22.79 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SE APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.42 9.60
February 22.89 11.29
March 22.92 12.66
April 22.62 13.68
May 22.46 15.00
June 22.50 15.34
July 22.57 15.94
August 23.11 16.62
September 23.37 16.72
October 23.21 15.11
November 23.42 12.79
December 23.02 10.66
     
Annual Sum or Average 22.87 13.79
Minimum of Months 22.42 9.60
Maximum of Months 23.42 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NE APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.74 9.60
February 21.85 11.29
March 22.02 12.66
April 22.19 13.68
May 22.25 15.00
June 22.38 15.34
July 22.31 15.94
August 22.69 16.62
September 22.58 16.72
October 22.39 15.11
November 22.32 12.79
December 21.82 10.66
     
Annual Sum or Average 22.21 13.79
Minimum of Months 21.74 9.60
Maximum of Months 22.69 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N1 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.81 9.60
February 21.92 11.29
March 22.13 12.66
April 22.26 13.68
May 22.30 15.00
June 22.39 15.34
July 22.37 15.94
August 22.72 16.62
September 22.68 16.72
October 22.54 15.11
November 22.60 12.79
December 21.97 10.66
     
Annual Sum or Average 22.31 13.79
Minimum of Months 21.81 9.60
Maximum of Months 22.72 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N2 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.80 9.60
February 21.92 11.29
March 22.12 12.66
April 22.26 13.68
May 22.30 15.00
June 22.39 15.34
July 22.36 15.94
August 22.71 16.62
September 22.66 16.72
October 22.54 15.11
November 22.59 12.79
December 21.96 10.66
     
Annual Sum or Average 22.30 13.79
Minimum of Months 21.80 9.60
Maximum of Months 22.71 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S1 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.98 9.60
February 23.55 11.29
March 23.38 12.66
April 22.89 13.68
May 22.58 15.00
June 22.56 15.34
July 22.67 15.94
August 23.24 16.62
September 23.57 16.72
October 23.56 15.11
November 23.90 12.79
December 23.61 10.66
     
Annual Sum or Average 23.21 13.79
Minimum of Months 22.56 9.60
Maximum of Months 23.90 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S2 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.98 9.60
February 23.54 11.29
March 23.38 12.66
April 22.89 13.68
May 22.58 15.00
June 22.56 15.34
July 22.66 15.94
August 23.24 16.62
September 23.57 16.72
October 23.55 15.11
November 23.90 12.79
December 23.61 10.66
     
Annual Sum or Average 23.20 13.79
Minimum of Months 22.56 9.60
Maximum of Months 23.90 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 CORRIDOR

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.98 9.60
February 23.49 11.29
March 23.65 12.66
April 23.61 13.68
May 23.61 15.00
June 23.67 15.34
July 23.86 15.94
August 24.30 16.62
September 24.42 16.72
October 24.14 15.11
November 24.06 12.79
December 23.42 10.66
     
Annual Sum or Average 23.77 13.79
Minimum of Months 22.98 9.60
Maximum of Months 24.42 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SW APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.35 9.60
February 22.82 11.29
March 22.87 12.66
April 22.55 13.68
May 22.41 15.00
June 22.45 15.34
July 22.59 15.94
August 23.10 16.62
September 23.36 16.72
October 23.14 15.11
November 23.34 12.79
December 22.93 10.66
     
Annual Sum or Average 22.83 13.79
Minimum of Months 22.35 9.60
Maximum of Months 23.36 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NW APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.76 9.60
February 21.86 11.29
March 22.02 12.66
April 22.17 13.68
May 22.25 15.00
June 22.37 15.34
July 22.38 15.94
August 22.73 16.62
September 22.64 16.72
October 22.38 15.11
November 22.34 12.79
December 21.87 10.66
     
Annual Sum or Average 22.23 13.79
Minimum of Months 21.76 9.60
Maximum of Months 22.73 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SE APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.33 9.60
February 22.76 11.29
March 22.81 12.66
April 22.55 13.68
May 22.42 15.00
June 22.47 15.34
July 22.52 15.94
August 23.04 16.62
September 23.27 16.72
October 23.09 15.11
November 23.30 12.79
December 22.89 10.66
     
Annual Sum or Average 22.79 13.79
Minimum of Months 22.33 9.60
Maximum of Months 23.30 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NE APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 9.60
February 21.83 11.29
March 21.99 12.66
April 22.16 13.68
May 22.22 15.00
June 22.35 15.34
July 22.28 15.94
August 22.63 16.62
September 22.52 16.72
October 22.33 15.11
November 22.24 12.79
December 21.79 10.66
     
Annual Sum or Average 22.17 13.79
Minimum of Months 21.73 9.60
Maximum of Months 22.63 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N1 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.78 9.60
February 21.88 11.29
March 22.08 12.66
April 22.22 13.68
May 22.28 15.00
June 22.38 15.34
July 22.34 15.94
August 22.68 16.62
September 22.63 16.72
October 22.48 15.11
November 22.49 12.79
December 21.91 10.66
     
Annual Sum or Average 22.26 13.79
Minimum of Months 21.78 9.60
Maximum of Months 22.68 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N2 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.78 9.60
February 21.88 11.29
March 22.07 12.66
April 22.22 13.68
May 22.27 15.00
June 22.37 15.34
July 22.33 15.94
August 22.67 16.62
September 22.62 16.72
October 22.47 15.11
November 22.48 12.79
December 21.91 10.66
     
Annual Sum or Average 22.26 13.79
Minimum of Months 21.78 9.60
Maximum of Months 22.67 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S1 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.82 9.60
February 23.37 11.29
March 23.25 12.66
April 22.80 13.68
May 22.53 15.00
June 22.53 15.34
July 22.63 15.94
August 23.17 16.62
September 23.49 16.72
October 23.44 15.11
November 23.77 12.79
December 23.45 10.66
     
Annual Sum or Average 23.10 13.79
Minimum of Months 22.53 9.60
Maximum of Months 23.77 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S2 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.82 9.60
February 23.36 11.29
March 23.24 12.66
April 22.80 13.68
May 22.53 15.00
June 22.53 15.34
July 22.62 15.94
August 23.17 16.62
September 23.48 16.72
October 23.44 15.11
November 23.77 12.79
December 23.44 10.66
     
Annual Sum or Average 23.10 13.79
Minimum of Months 22.53 9.60
Maximum of Months 23.77 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 CORRIDOR

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.83 9.60
February 23.35 11.29
March 23.54 12.66
April 23.54 13.68
May 23.58 15.00
June 23.66 15.34
July 23.83 15.94
August 24.25 16.62
September 24.36 16.72
October 24.03 15.11
November 23.91 12.79
December 23.26 10.66
     
Annual Sum or Average 23.68 13.79
Minimum of Months 22.83 9.60
Maximum of Months 24.36 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.26 9.60
February 22.59 11.29
March 22.65 12.66
April 22.50 13.68
May 22.37 15.00
June 22.42 15.34
July 22.48 15.94
August 22.86 16.62
September 23.04 16.72
October 22.84 15.11
November 22.98 12.79
December 22.64 10.66
     
Annual Sum or Average 22.64 13.79
Minimum of Months 22.26 9.60
Maximum of Months 23.04 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.79 9.60
February 21.95 11.29
March 22.07 12.66
April 22.18 13.68
May 22.23 15.00
June 22.34 15.34
July 22.31 15.94
August 22.56 16.62
September 22.50 16.72
October 22.27 15.11
November 22.30 12.79
December 21.93 10.66
     
Annual Sum or Average 22.20 13.79
Minimum of Months 21.79 9.60
Maximum of Months 22.56 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.25 9.60
February 22.56 11.29
March 22.61 12.66
April 22.49 13.68
May 22.38 15.00
June 22.43 15.34
July 22.44 15.94
August 22.81 16.62
September 22.97 16.72
October 22.80 15.11
November 22.94 12.79
December 22.62 10.66
     
Annual Sum or Average 22.61 13.79
Minimum of Months 22.25 9.60
Maximum of Months 22.97 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.75 9.60
February 21.91 11.29
March 22.06 12.66
April 22.18 13.68
May 22.22 15.00
June 22.34 15.34
July 22.25 15.94
August 22.50 16.62
September 22.42 16.72
October 22.26 15.11
November 22.23 12.79
December 21.83 10.66
     
Annual Sum or Average 22.16 13.79
Minimum of Months 21.75 9.60
Maximum of Months 22.50 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.78 9.60
February 21.93 11.29
March 22.07 12.66
April 22.20 13.68
May 22.24 15.00
June 22.34 15.34
July 22.27 15.94
August 22.55 16.62
September 22.50 16.72
October 22.33 15.11
November 22.36 12.79
December 21.91 10.66
     
Annual Sum or Average 22.21 13.79
Minimum of Months 21.78 9.60
Maximum of Months 22.55 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.78 9.60
February 21.93 11.29
March 22.07 12.66
April 22.20 13.68
May 22.23 15.00
June 22.34 15.34
July 22.26 15.94
August 22.54 16.62
September 22.49 16.72
October 22.33 15.11
November 22.35 12.79
December 21.90 10.66
     
Annual Sum or Average 22.20 13.79
Minimum of Months 21.78 9.60
Maximum of Months 22.54 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.50 9.60
February 22.91 11.29
March 22.93 12.66
April 22.67 13.68
May 22.47 15.00
June 22.48 15.34
July 22.54 15.94
August 23.00 16.62
September 23.25 16.72
October 23.11 15.11
November 23.36 12.79
December 22.97 10.66
     
Annual Sum or Average 22.85 13.79
Minimum of Months 22.47 9.60
Maximum of Months 23.36 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.50 9.60
February 22.91 11.29
March 22.93 12.66
April 22.67 13.68
May 22.47 15.00
June 22.48 15.34
July 22.54 15.94
August 22.99 16.62
September 23.24 16.72
October 23.11 15.11
November 23.35 12.79
December 22.97 10.66
     
Annual Sum or Average 22.85 13.79
Minimum of Months 22.47 9.60
Maximum of Months 23.35 16.72



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2015-09-09 19:12:07

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.96 9.60
February 23.59 11.29
March 23.91 12.66
April 24.03 13.68
May 24.14 15.00
June 24.27 15.34
July 24.42 15.94
August 24.79 16.62
September 24.85 16.72
October 24.37 15.11
November 24.12 12.79
December 23.36 10.66
     
Annual Sum or Average 24.07 13.79
Minimum of Months 22.96 9.60
Maximum of Months 24.85 16.72



Table of Contents

Report: COMPONENTS OF PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2015-09-09 19:12:07

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY {AT MAX/MIN} [W] HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W]
January 0.196668E+12 112332.369 31-JAN-18:15 13120.457 57042.023 15015.237 13470.532 0.000 10364.000 1332.309 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
February 0.173052E+12 106111.159 13-FEB-18:45 13120.457 57042.023 15015.237 7249.125 0.000 10364.000 1332.309 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
March 0.190329E+12 112436.715 13-MAR-16:15 11327.174 57142.088 15015.237 0.000 24733.254 0.000 1332.309 891.457 0.000 0.000 0.000 0.000 0.000 0.000 0.000
April 0.183387E+12 130720.933 02-APR-17:15 13120.457 57042.023 15015.237 0.000 40920.865 0.000 1332.309 1302.231 0.000 0.000 0.000 0.000 0.000 0.000 0.000
May 0.188168E+12 129216.718 17-MAY-19:00 14401.373 49889.926 15015.237 36572.570 0.000 10364.000 1332.309 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
June 0.183256E+12 135664.155 30-JUN-16:45 11327.174 57142.088 15015.237 0.000 47332.163 0.000 1332.309 1520.026 0.000 0.000 0.000 0.000 0.000 0.000 0.000
July 0.183675E+12 130110.870 09-JUL-19:30 14401.373 49889.926 15015.237 37466.721 0.000 10364.000 1332.309 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 0.188618E+12 123149.851 03-AUG-16:15 11327.174 57142.088 15015.237 0.000 34925.401 0.000 1332.309 1412.446 0.000 0.000 0.000 0.000 0.000 0.000 0.000
September 0.185118E+12 131223.180 11-SEP-18:15 14401.373 51749.961 15015.237 46963.402 0.000 0.000 1332.309 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
October 0.192143E+12 130309.391 09-OCT-17:15 13120.457 57042.023 15015.237 41811.553 0.000 0.000 1332.309 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
November 0.187267E+12 134468.198 20-NOV-18:00 13120.457 57042.023 15015.237 35606.163 0.000 10364.000 1332.309 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
December 0.195594E+12 104449.334 29-DEC-18:00 13120.457 57042.023 15015.237 0.000 5373.330 10364.000 1332.309 213.970 0.000 0.000 0.000 0.000 0.000 0.000 0.000
                                     
Annual Sum or Average 0.224728E+13                     0.000 0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.173052E+12 104449.334   11327.174 49889.926 15015.237 0.000 0.000 0.000 1332.309 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.196668E+12 135664.155   14401.373 57142.088 15015.237 46963.402 47332.163 10364.000 1332.309 1520.026 0.000 0.000 0.000 0.000 0.000 0.000 0.000



Table of Contents

Report: COMPONENTS OF PEAK GAS DEMAND

For: Meter

Timestamp: 2015-09-09 19:12:07

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC [Invalid/Undefined] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT {AT MAX/MIN} [W] WATERSYSTEMS:GAS {AT MAX/MIN} [W] WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] HEATING:GAS {AT MAX/MIN} [W]
January 0.126285E+12 145527.951 26-JAN-08:00 0.000 0.000 0.000 145527.951 76075.582 76075.582 69452.369
February 0.952011E+11 102727.333 02-FEB-08:30 0.000 0.000 0.000 102727.333 76213.731 76213.731 26513.603
March 0.106794E+12 141065.923 12-MAR-08:30 0.000 0.000 0.000 141065.923 72614.208 72614.208 68451.715
April 0.107240E+12 167510.962 25-APR-15:00 0.000 0.000 0.000 167510.962 48233.645 48233.645 119277.317
May 0.111409E+12 187090.971 17-MAY-19:00 0.000 0.000 0.000 187090.971 68877.576 68877.576 118213.395
June 0.100885E+12 160664.881 09-JUN-17:00 0.000 0.000 0.000 160664.881 71293.915 71293.915 89370.966
July 0.980031E+11 167559.444 09-JUL-19:30 0.000 0.000 0.000 167559.444 57779.494 57779.494 109779.949
August 0.916017E+11 134522.286 16-AUG-17:15 0.000 0.000 0.000 134522.286 69092.417 69092.417 65429.869
September 0.891593E+11 169766.774 11-SEP-17:00 0.000 0.000 0.000 169766.774 70898.170 70898.170 98868.604
October 0.975194E+11 157117.463 03-OCT-09:00 0.000 0.000 0.000 157117.463 53194.808 53194.808 103922.655
November 0.934100E+11 142561.233 20-NOV-19:30 0.000 0.000 0.000 142561.233 71106.771 71106.771 71454.462
December 0.110800E+12 157345.229 22-DEC-06:30 0.000 0.000 0.000 157345.229 65485.906 65485.906 91859.323
                     
Annual Sum or Average 0.122831E+13     0.000 0.000 0.000        
Minimum of Months 0.891593E+11 102727.333   0.000 0.000 0.000 102727.333 48233.645 48233.645 26513.603
Maximum of Months 0.126285E+12 187090.971   0.000 0.000 0.000 187090.971 76213.731 76213.731 119277.317