Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:59
Tabular Output Report in Format: HTML
Building: High-Rise Apartment
Environment: Baltimore Blt Washngtn IntL MD USA TMY3 WMO#=724060
Simulation Timestamp: 2015-09-09 19:00:30
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 4872.86 | 621.82 | 690.22 |
Net Site Energy | 4872.86 | 621.82 | 690.22 |
Total Source Energy | 11655.92 | 1487.39 | 1651.01 |
Net Source Energy | 11655.92 | 1487.39 | 1651.01 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 7836.48 |
Net Conditioned Building Area | 7059.89 |
Unconditioned Building Area | 776.58 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 199.37 | 707.16 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 491.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 296.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 162.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1137.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 640.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 72.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 23.01 | 0.00 | 0.00 | 0.00 | 0.00 | 1369.16 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 1105.82 | 0.00 | 0.00 | 0.00 | 4778.51 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 3059.89 | 1812.97 | 0.00 | 0.00 | 0.00 | 6147.67 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Boiler | 0.00 | 707.16 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Other | 199.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 491.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 242.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 54.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 162.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 1137.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 640.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 72.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 23.01 | 0.00 | 0.00 | 0.00 | 0.00 | 1369.16 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 1105.82 | 0.00 | 0.00 | 0.00 | 0.00 |
sub cat | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4778.51 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 65.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 202.12 | 256.80 | 0.00 | 0.00 | 0.00 | 0.87 |
Other | 161.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 433.42 | 256.80 | 0.00 | 0.00 | 0.00 | 0.87 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 58.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 182.09 | 231.35 | 0.00 | 0.00 | 0.00 | 0.78 |
Other | 145.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 390.47 | 231.35 | 0.00 | 0.00 | 0.00 | 0.78 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 3059.89 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 3059.89 | 100.00 |
Total On-Site and Utility Electric Sources | 3059.89 | 100.00 |
Total Electricity End Uses | 3059.89 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 6147.67 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 6147.67 | 100.00 |
Total Water End Uses | 6147.67 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 114.00 |
Time Setpoint Not Met During Occupied Cooling | 71.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 2612.75 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |COMPONENTS OF PEAK ELECTRICAL DEMAND
| Meter |COMPONENTS OF PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:59 |
RunPeriod | Baltimore Blt Washngtn IntL MD USA TMY3 WMO#=724060 |
Weather File | Baltimore Blt Washngtn IntL MD USA TMY3 WMO#=724060 |
Latitude [deg] | 39.17 |
Longitude [deg] | -76.7 |
Elevation [m] | 45.00 |
Time Zone | -5.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 3855.02 | 1411.96 | 515.55 | 1411.96 | 515.55 |
Window Opening Area [m2] | 1150.39 | 423.59 | 152.73 | 423.59 | 150.48 |
Window-Wall Ratio [%] | 29.84 | 30.00 | 29.62 | 30.00 | 29.19 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 3752.84 | 1411.96 | 464.46 | 1411.96 | 464.46 |
Window Opening Area [m2] | 1125.85 | 423.59 | 139.34 | 423.59 | 139.34 |
Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 29.5362 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 4.47 | 6.7128 | 0.0000 | |
F2 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F3 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F4 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
M SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 13.4255 | 0.0000 | |
F6 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F7 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F8 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F9 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
T SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 264.3872 | |
Total | 7836.48 | 23884.04 | 3855.02 | 1150.39 | 4.3335 | 39.48 | 8.6291 | |||
Conditioned Total | 7059.89 | 21517.16 | 3752.84 | 1125.85 | 3.9979 | 35.57 | 6.6700 | |||
Unconditioned Total | 776.58 | 2366.87 | 102.18 | 24.54 | 7.3840 | 26.4387 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 03-SEP-18:45 | 25-DEC-07:15 | - | - | - | 09-JUL-17:15 |
Heating | 0.00 | 287479.30 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 81177.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 14401.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 10364.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 51749.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 20311.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 2374.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 3478.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 78213.16 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 185618.30 | 365692.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | Boiler | 0.00 | 287479.30 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 81177.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 11484.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 2917.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 10364.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 51749.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 20311.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 2374.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 3478.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 78213.16 | 0.00 | 0.00 | 0.00 | 0.00 |
sub cat | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 631.41 | 766.56 | 0.00 | 0.00 | 0.00 |
Cooling | 1555.62 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 939.20 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 515.84 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 3601.91 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 2028.61 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 230.65 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 72.87 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 1198.70 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 9690.66 | 1965.26 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 89.44 | 108.58 | 0.00 | 0.00 | 0.00 |
Cooling | 220.35 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 133.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 73.07 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 510.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 287.34 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 32.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 10.32 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 169.79 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1372.64 | 278.37 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 89.44 | 108.58 | 0.00 | 0.00 | 0.00 |
Cooling | 220.35 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 133.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 73.07 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 510.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 287.34 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 32.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 10.32 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 169.79 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1372.64 | 278.37 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | -10.60 | 0.00 | -10.60 | Wetbulb [C] | 3.90 | 290.00 |
BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 34.40 | 10.40 | 23.90 | Wetbulb [C] | 4.60 | 280.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 270.00 | 180.00 | |
F2 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F2 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F2 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F2 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F2 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F2 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F3 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F3 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F3 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F3 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F3 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F3 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F4 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F4 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F4 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F4 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F4 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F4 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F6 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F6 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F6 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F6 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F6 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F6 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F7 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F7 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F7 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F7 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F7 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F7 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F8 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F8 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F8 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F8 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F8 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F8 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F9 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F9 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F9 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F9 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F9 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F9 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.30 | 0.269 | 0.283 | 77.66 | 0.00 | 0.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
GWINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | G WWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_0.48_SHGC_0.40 | 3.36 | 0.00 | 0.00 | 3.36 | 3.36 | 2.653 | 0.426 | 0.308 | No | G EWALL C | 90.00 | 90.00 | E | ||
F2WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F2 WWALL SWA | 270.00 | 90.00 | W | ||
F2WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 SWALL SWA | 180.00 | 90.00 | S | ||
F2WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 NWALL NWA | 0.00 | 90.00 | N | ||
F2WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F2 WWALL NWA | 270.00 | 90.00 | W | ||
F2WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F2 EWALL SEA | 90.00 | 90.00 | E | ||
F2WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 SWALL SEA | 180.00 | 90.00 | S | ||
F2WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 NWALL NEA | 0.00 | 90.00 | N | ||
F2WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F2 EWALL NEA | 90.00 | 90.00 | E | ||
F2WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 NWALL N1A | 0.00 | 90.00 | N | ||
F2WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 NWALL N2A | 0.00 | 90.00 | N | ||
F2WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 SWALL S1A | 180.00 | 90.00 | S | ||
F2WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 SWALL S2A | 180.00 | 90.00 | S | ||
F2WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F2 WWALL C | 270.00 | 90.00 | W | ||
F2WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F2 EWALL C | 90.00 | 90.00 | E | ||
F3WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F3 WWALL SWA | 270.00 | 90.00 | W | ||
F3WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 SWALL SWA | 180.00 | 90.00 | S | ||
F3WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 NWALL NWA | 0.00 | 90.00 | N | ||
F3WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F3 WWALL NWA | 270.00 | 90.00 | W | ||
F3WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F3 EWALL SEA | 90.00 | 90.00 | E | ||
F3WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 SWALL SEA | 180.00 | 90.00 | S | ||
F3WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 NWALL NEA | 0.00 | 90.00 | N | ||
F3WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F3 EWALL NEA | 90.00 | 90.00 | E | ||
F3WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 NWALL N1A | 0.00 | 90.00 | N | ||
F3WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 NWALL N2A | 0.00 | 90.00 | N | ||
F3WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 SWALL S1A | 180.00 | 90.00 | S | ||
F3WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 SWALL S2A | 180.00 | 90.00 | S | ||
F3WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F3 WWALL C | 270.00 | 90.00 | W | ||
F3WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F3 EWALL C | 90.00 | 90.00 | E | ||
F4WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F4 WWALL SWA | 270.00 | 90.00 | W | ||
F4WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 SWALL SWA | 180.00 | 90.00 | S | ||
F4WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 NWALL NWA | 0.00 | 90.00 | N | ||
F4WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F4 WWALL NWA | 270.00 | 90.00 | W | ||
F4WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F4 EWALL SEA | 90.00 | 90.00 | E | ||
F4WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 SWALL SEA | 180.00 | 90.00 | S | ||
F4WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 NWALL NEA | 0.00 | 90.00 | N | ||
F4WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F4 EWALL NEA | 90.00 | 90.00 | E | ||
F4WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 NWALL N1A | 0.00 | 90.00 | N | ||
F4WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 NWALL N2A | 0.00 | 90.00 | N | ||
F4WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 SWALL S1A | 180.00 | 90.00 | S | ||
F4WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 SWALL S2A | 180.00 | 90.00 | S | ||
F4WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F4 WWALL C | 270.00 | 90.00 | W | ||
F4WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F4 EWALL C | 90.00 | 90.00 | E | ||
MWINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | M WWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | M EWALL C | 90.00 | 90.00 | E | ||
F6WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F6 WWALL SWA | 270.00 | 90.00 | W | ||
F6WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 SWALL SWA | 180.00 | 90.00 | S | ||
F6WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 NWALL NWA | 0.00 | 90.00 | N | ||
F6WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F6 WWALL NWA | 270.00 | 90.00 | W | ||
F6WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F6 EWALL SEA | 90.00 | 90.00 | E | ||
F6WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 SWALL SEA | 180.00 | 90.00 | S | ||
F6WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 NWALL NEA | 0.00 | 90.00 | N | ||
F6WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F6 EWALL NEA | 90.00 | 90.00 | E | ||
F6WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 NWALL N1A | 0.00 | 90.00 | N | ||
F6WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 NWALL N2A | 0.00 | 90.00 | N | ||
F6WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 SWALL S1A | 180.00 | 90.00 | S | ||
F6WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 SWALL S2A | 180.00 | 90.00 | S | ||
F6WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F6 WWALL C | 270.00 | 90.00 | W | ||
F6WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F6 EWALL C | 90.00 | 90.00 | E | ||
F7WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F7 WWALL SWA | 270.00 | 90.00 | W | ||
F7WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 SWALL SWA | 180.00 | 90.00 | S | ||
F7WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 NWALL NWA | 0.00 | 90.00 | N | ||
F7WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F7 WWALL NWA | 270.00 | 90.00 | W | ||
F7WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F7 EWALL SEA | 90.00 | 90.00 | E | ||
F7WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 SWALL SEA | 180.00 | 90.00 | S | ||
F7WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 NWALL NEA | 0.00 | 90.00 | N | ||
F7WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F7 EWALL NEA | 90.00 | 90.00 | E | ||
F7WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 NWALL N1A | 0.00 | 90.00 | N | ||
F7WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 NWALL N2A | 0.00 | 90.00 | N | ||
F7WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 SWALL S1A | 180.00 | 90.00 | S | ||
F7WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 SWALL S2A | 180.00 | 90.00 | S | ||
F7WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F7 WWALL C | 270.00 | 90.00 | W | ||
F7WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F7 EWALL C | 90.00 | 90.00 | E | ||
F8WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F8 WWALL SWA | 270.00 | 90.00 | W | ||
F8WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 SWALL SWA | 180.00 | 90.00 | S | ||
F8WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 NWALL NWA | 0.00 | 90.00 | N | ||
F8WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F8 WWALL NWA | 270.00 | 90.00 | W | ||
F8WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F8 EWALL SEA | 90.00 | 90.00 | E | ||
F8WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 SWALL SEA | 180.00 | 90.00 | S | ||
F8WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 NWALL NEA | 0.00 | 90.00 | N | ||
F8WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F8 EWALL NEA | 90.00 | 90.00 | E | ||
F8WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 NWALL N1A | 0.00 | 90.00 | N | ||
F8WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 NWALL N2A | 0.00 | 90.00 | N | ||
F8WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 SWALL S1A | 180.00 | 90.00 | S | ||
F8WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 SWALL S2A | 180.00 | 90.00 | S | ||
F8WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F8 WWALL C | 270.00 | 90.00 | W | ||
F8WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F8 EWALL C | 90.00 | 90.00 | E | ||
F9WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F9 WWALL SWA | 270.00 | 90.00 | W | ||
F9WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 SWALL SWA | 180.00 | 90.00 | S | ||
F9WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 NWALL NWA | 0.00 | 90.00 | N | ||
F9WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F9 WWALL NWA | 270.00 | 90.00 | W | ||
F9WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F9 EWALL SEA | 90.00 | 90.00 | E | ||
F9WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 SWALL SEA | 180.00 | 90.00 | S | ||
F9WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 NWALL NEA | 0.00 | 90.00 | N | ||
F9WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F9 EWALL NEA | 90.00 | 90.00 | E | ||
F9WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 NWALL N1A | 0.00 | 90.00 | N | ||
F9WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 NWALL N2A | 0.00 | 90.00 | N | ||
F9WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 SWALL S1A | 180.00 | 90.00 | S | ||
F9WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 SWALL S2A | 180.00 | 90.00 | S | ||
F9WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F9 WWALL C | 270.00 | 90.00 | W | ||
F9WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F9 EWALL C | 90.00 | 90.00 | E | ||
TWINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | T WWALL C | 270.00 | 90.00 | W | ||
TWINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | T EWALL C | 90.00 | 90.00 | E | ||
Total or Average | 1150.39 | 2.653 | 0.426 | 0.308 | ||||||||||||
North Total or Average | 423.59 | 2.653 | 0.426 | 0.308 | ||||||||||||
Non-North Total or Average | 726.80 | 2.653 | 0.426 | 0.308 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
G SW APARTMENT_LIGHTS_HARDWIRED | G SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G NW APARTMENT_LIGHTS_HARDWIRED | G NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
OFFICE_LIGHTS_HARDWIRED | OFFICE | 14.7681 | 88.25 | 1303.26 | GeneralLights | LTG_OFF_SCH | 62.05 | 168.00 | 61.07 | 0.0000 | Y | 14.94 |
G NE APARTMENT_LIGHTS_HARDWIRED | G NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G N1 APARTMENT_LIGHTS_HARDWIRED | G N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G N2 APARTMENT_LIGHTS_HARDWIRED | G N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G S1 APARTMENT_LIGHTS_HARDWIRED | G S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G S2 APARTMENT_LIGHTS_HARDWIRED | G S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G CORRIDOR_LIGHTS_HARDWIRED | G CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F2 SW APARTMENT_LIGHTS_HARDWIRED | F2 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 NW APARTMENT_LIGHTS_HARDWIRED | F2 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 SE APARTMENT_LIGHTS_HARDWIRED | F2 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 NE APARTMENT_LIGHTS_HARDWIRED | F2 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 N1 APARTMENT_LIGHTS_HARDWIRED | F2 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 N2 APARTMENT_LIGHTS_HARDWIRED | F2 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 S1 APARTMENT_LIGHTS_HARDWIRED | F2 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 S2 APARTMENT_LIGHTS_HARDWIRED | F2 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 CORRIDOR_LIGHTS_HARDWIRED | F2 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F3 SW APARTMENT_LIGHTS_HARDWIRED | F3 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 NW APARTMENT_LIGHTS_HARDWIRED | F3 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 SE APARTMENT_LIGHTS_HARDWIRED | F3 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 NE APARTMENT_LIGHTS_HARDWIRED | F3 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 N1 APARTMENT_LIGHTS_HARDWIRED | F3 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 N2 APARTMENT_LIGHTS_HARDWIRED | F3 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 S1 APARTMENT_LIGHTS_HARDWIRED | F3 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 S2 APARTMENT_LIGHTS_HARDWIRED | F3 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 CORRIDOR_LIGHTS_HARDWIRED | F3 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F4 SW APARTMENT_LIGHTS_HARDWIRED | F4 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 NW APARTMENT_LIGHTS_HARDWIRED | F4 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 SE APARTMENT_LIGHTS_HARDWIRED | F4 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 NE APARTMENT_LIGHTS_HARDWIRED | F4 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 N1 APARTMENT_LIGHTS_HARDWIRED | F4 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 N2 APARTMENT_LIGHTS_HARDWIRED | F4 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 S1 APARTMENT_LIGHTS_HARDWIRED | F4 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 S2 APARTMENT_LIGHTS_HARDWIRED | F4 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 CORRIDOR_LIGHTS_HARDWIRED | F4 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
M SW APARTMENT_LIGHTS_HARDWIRED | M SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M NW APARTMENT_LIGHTS_HARDWIRED | M NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M SE APARTMENT_LIGHTS_HARDWIRED | M SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M NE APARTMENT_LIGHTS_HARDWIRED | M NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M N1 APARTMENT_LIGHTS_HARDWIRED | M N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M N2 APARTMENT_LIGHTS_HARDWIRED | M N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M S1 APARTMENT_LIGHTS_HARDWIRED | M S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M S2 APARTMENT_LIGHTS_HARDWIRED | M S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M CORRIDOR_LIGHTS_HARDWIRED | M CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F6 SW APARTMENT_LIGHTS_HARDWIRED | F6 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 NW APARTMENT_LIGHTS_HARDWIRED | F6 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 SE APARTMENT_LIGHTS_HARDWIRED | F6 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 NE APARTMENT_LIGHTS_HARDWIRED | F6 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 N1 APARTMENT_LIGHTS_HARDWIRED | F6 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 N2 APARTMENT_LIGHTS_HARDWIRED | F6 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 S1 APARTMENT_LIGHTS_HARDWIRED | F6 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 S2 APARTMENT_LIGHTS_HARDWIRED | F6 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 CORRIDOR_LIGHTS_HARDWIRED | F6 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F7 SW APARTMENT_LIGHTS_HARDWIRED | F7 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 NW APARTMENT_LIGHTS_HARDWIRED | F7 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 SE APARTMENT_LIGHTS_HARDWIRED | F7 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 NE APARTMENT_LIGHTS_HARDWIRED | F7 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 N1 APARTMENT_LIGHTS_HARDWIRED | F7 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 N2 APARTMENT_LIGHTS_HARDWIRED | F7 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 S1 APARTMENT_LIGHTS_HARDWIRED | F7 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 S2 APARTMENT_LIGHTS_HARDWIRED | F7 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 CORRIDOR_LIGHTS_HARDWIRED | F7 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F8 SW APARTMENT_LIGHTS_HARDWIRED | F8 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 NW APARTMENT_LIGHTS_HARDWIRED | F8 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 SE APARTMENT_LIGHTS_HARDWIRED | F8 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 NE APARTMENT_LIGHTS_HARDWIRED | F8 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 N1 APARTMENT_LIGHTS_HARDWIRED | F8 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 N2 APARTMENT_LIGHTS_HARDWIRED | F8 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 S1 APARTMENT_LIGHTS_HARDWIRED | F8 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 S2 APARTMENT_LIGHTS_HARDWIRED | F8 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 CORRIDOR_LIGHTS_HARDWIRED | F8 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F9 SW APARTMENT_LIGHTS_HARDWIRED | F9 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 NW APARTMENT_LIGHTS_HARDWIRED | F9 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 SE APARTMENT_LIGHTS_HARDWIRED | F9 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 NE APARTMENT_LIGHTS_HARDWIRED | F9 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 N1 APARTMENT_LIGHTS_HARDWIRED | F9 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 N2 APARTMENT_LIGHTS_HARDWIRED | F9 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 S1 APARTMENT_LIGHTS_HARDWIRED | F9 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 S2 APARTMENT_LIGHTS_HARDWIRED | F9 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 CORRIDOR_LIGHTS_HARDWIRED | F9 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
T SW APARTMENT_LIGHTS_HARDWIRED | T SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T NW APARTMENT_LIGHTS_HARDWIRED | T NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T SE APARTMENT_LIGHTS_HARDWIRED | T SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T NE APARTMENT_LIGHTS_HARDWIRED | T NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T N1 APARTMENT_LIGHTS_HARDWIRED | T N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T N2 APARTMENT_LIGHTS_HARDWIRED | T N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T S1 APARTMENT_LIGHTS_HARDWIRED | T S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T S2 APARTMENT_LIGHTS_HARDWIRED | T S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T CORRIDOR_LIGHTS_HARDWIRED | T CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
G SW APARTMENT_LIGHTS_PLUGIN | G SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G NW APARTMENT_LIGHTS_PLUGIN | G NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
OFFICE_LIGHTS_PLUGIN | OFFICE | 14.7681 | 88.25 | 1303.26 | GeneralLights-plugin | LTG_OFF_SCH | 62.05 | 168.00 | 61.07 | 0.0000 | Y | 14.94 |
G NE APARTMENT_LIGHTS_PLUGIN | G NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G N1 APARTMENT_LIGHTS_PLUGIN | G N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G N2 APARTMENT_LIGHTS_PLUGIN | G N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G S1 APARTMENT_LIGHTS_PLUGIN | G S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G S2 APARTMENT_LIGHTS_PLUGIN | G S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 SW APARTMENT_LIGHTS_PLUGIN | F2 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 NW APARTMENT_LIGHTS_PLUGIN | F2 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 SE APARTMENT_LIGHTS_PLUGIN | F2 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 NE APARTMENT_LIGHTS_PLUGIN | F2 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 N1 APARTMENT_LIGHTS_PLUGIN | F2 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 N2 APARTMENT_LIGHTS_PLUGIN | F2 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 S1 APARTMENT_LIGHTS_PLUGIN | F2 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 S2 APARTMENT_LIGHTS_PLUGIN | F2 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 SW APARTMENT_LIGHTS_PLUGIN | F3 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 NW APARTMENT_LIGHTS_PLUGIN | F3 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 SE APARTMENT_LIGHTS_PLUGIN | F3 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 NE APARTMENT_LIGHTS_PLUGIN | F3 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 N1 APARTMENT_LIGHTS_PLUGIN | F3 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 N2 APARTMENT_LIGHTS_PLUGIN | F3 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 S1 APARTMENT_LIGHTS_PLUGIN | F3 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 S2 APARTMENT_LIGHTS_PLUGIN | F3 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 SW APARTMENT_LIGHTS_PLUGIN | F4 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 NW APARTMENT_LIGHTS_PLUGIN | F4 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 SE APARTMENT_LIGHTS_PLUGIN | F4 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 NE APARTMENT_LIGHTS_PLUGIN | F4 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 N1 APARTMENT_LIGHTS_PLUGIN | F4 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 N2 APARTMENT_LIGHTS_PLUGIN | F4 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 S1 APARTMENT_LIGHTS_PLUGIN | F4 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 S2 APARTMENT_LIGHTS_PLUGIN | F4 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M SW APARTMENT_LIGHTS_PLUGIN | M SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M NW APARTMENT_LIGHTS_PLUGIN | M NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M SE APARTMENT_LIGHTS_PLUGIN | M SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M NE APARTMENT_LIGHTS_PLUGIN | M NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M N1 APARTMENT_LIGHTS_PLUGIN | M N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M N2 APARTMENT_LIGHTS_PLUGIN | M N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M S1 APARTMENT_LIGHTS_PLUGIN | M S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M S2 APARTMENT_LIGHTS_PLUGIN | M S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M CORRIDOR_LIGHTS_PLUGIN | M CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights-plugin | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F6 SW APARTMENT_LIGHTS_PLUGIN | F6 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 NW APARTMENT_LIGHTS_PLUGIN | F6 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 SE APARTMENT_LIGHTS_PLUGIN | F6 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 NE APARTMENT_LIGHTS_PLUGIN | F6 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 N1 APARTMENT_LIGHTS_PLUGIN | F6 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 N2 APARTMENT_LIGHTS_PLUGIN | F6 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 S1 APARTMENT_LIGHTS_PLUGIN | F6 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 S2 APARTMENT_LIGHTS_PLUGIN | F6 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 SW APARTMENT_LIGHTS_PLUGIN | F7 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 NW APARTMENT_LIGHTS_PLUGIN | F7 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 SE APARTMENT_LIGHTS_PLUGIN | F7 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 NE APARTMENT_LIGHTS_PLUGIN | F7 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 N1 APARTMENT_LIGHTS_PLUGIN | F7 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 N2 APARTMENT_LIGHTS_PLUGIN | F7 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 S1 APARTMENT_LIGHTS_PLUGIN | F7 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 S2 APARTMENT_LIGHTS_PLUGIN | F7 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 SW APARTMENT_LIGHTS_PLUGIN | F8 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 NW APARTMENT_LIGHTS_PLUGIN | F8 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 SE APARTMENT_LIGHTS_PLUGIN | F8 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 NE APARTMENT_LIGHTS_PLUGIN | F8 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 N1 APARTMENT_LIGHTS_PLUGIN | F8 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 N2 APARTMENT_LIGHTS_PLUGIN | F8 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 S1 APARTMENT_LIGHTS_PLUGIN | F8 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 S2 APARTMENT_LIGHTS_PLUGIN | F8 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 SW APARTMENT_LIGHTS_PLUGIN | F9 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 NW APARTMENT_LIGHTS_PLUGIN | F9 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 SE APARTMENT_LIGHTS_PLUGIN | F9 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 NE APARTMENT_LIGHTS_PLUGIN | F9 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 N1 APARTMENT_LIGHTS_PLUGIN | F9 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 N2 APARTMENT_LIGHTS_PLUGIN | F9 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 S1 APARTMENT_LIGHTS_PLUGIN | F9 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 S2 APARTMENT_LIGHTS_PLUGIN | F9 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T SW APARTMENT_LIGHTS_PLUGIN | T SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T NW APARTMENT_LIGHTS_PLUGIN | T NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T SE APARTMENT_LIGHTS_PLUGIN | T SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T NE APARTMENT_LIGHTS_PLUGIN | T NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T N1 APARTMENT_LIGHTS_PLUGIN | T N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T N2 APARTMENT_LIGHTS_PLUGIN | T N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T S1 APARTMENT_LIGHTS_PLUGIN | T S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T S2 APARTMENT_LIGHTS_PLUGIN | T S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
Interior Lighting Total | 2.2679 | 14974.03 | 33959.19 | 296.56 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 10364.00 | AstronomicalClock | - | 83.72 | 83.72 | 162.88 | |
Exterior Lighting Total | 10364.00 | 162.88 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
CENTRAL BOILER | Boiler:HotWater | 336585.92 | 0.75 | ||
CENTRAL TOWER | EvaporativeFluidCooler:SingleSpeed | 269268.74 |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
HEAT PUMP COOLING MODE AIRLOOP G SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4068.34 | 2728.95 | 1339.39 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3852.75 | 2569.40 | 1283.36 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP OFFICE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5969.90 | 4056.24 | 1913.66 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3125.32 | 2030.66 | 1094.65 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2341.16 | 1471.97 | 869.19 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2319.26 | 1455.98 | 863.28 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2748.20 | 1758.43 | 989.77 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2835.58 | 1824.39 | 1011.19 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5089.12 | 3463.86 | 1625.26 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4813.92 | 3256.22 | 1557.71 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4949.47 | 3350.54 | 1598.93 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3988.74 | 2642.01 | 1346.74 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2943.25 | 1898.46 | 1044.79 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2925.58 | 1885.38 | 1040.20 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3436.13 | 2254.66 | 1181.46 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3466.69 | 2277.87 | 1188.82 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5194.08 | 3516.94 | 1677.14 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4925.64 | 3315.14 | 1610.50 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4775.27 | 3192.31 | 1582.96 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4110.79 | 2710.71 | 1400.08 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3034.20 | 1953.78 | 1080.42 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3016.63 | 1940.81 | 1075.82 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3529.69 | 2311.17 | 1218.52 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3543.01 | 2321.29 | 1221.72 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5282.11 | 3562.61 | 1719.51 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5006.65 | 3357.52 | 1649.13 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4832.38 | 3217.03 | 1615.35 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4184.98 | 2749.49 | 1435.49 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3090.28 | 1986.31 | 1103.96 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3072.72 | 1973.39 | 1099.33 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3586.35 | 2343.37 | 1242.98 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3597.21 | 2351.61 | 1245.59 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5378.50 | 3619.86 | 1758.64 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5102.44 | 3414.67 | 1687.78 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4927.95 | 3274.32 | 1653.63 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4283.46 | 2807.83 | 1475.63 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3164.21 | 2033.72 | 1130.49 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3146.69 | 2020.84 | 1125.85 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3660.25 | 2390.49 | 1269.77 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3670.77 | 2398.47 | 1272.30 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5385.45 | 3611.82 | 1773.64 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5111.59 | 3408.15 | 1703.44 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4936.97 | 3268.72 | 1668.24 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4283.98 | 2797.08 | 1486.89 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3151.76 | 2018.46 | 1133.30 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3134.29 | 2005.67 | 1128.62 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3649.20 | 2375.05 | 1274.15 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3659.69 | 2382.99 | 1276.70 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5415.98 | 3623.38 | 1792.60 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5141.65 | 3419.76 | 1721.89 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4969.42 | 3282.41 | 1687.01 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4309.83 | 2806.73 | 1503.10 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3165.69 | 2023.50 | 1142.19 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3148.25 | 2010.77 | 1137.49 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3663.51 | 2379.61 | 1283.90 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3674.01 | 2387.55 | 1286.46 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5461.03 | 3647.16 | 1813.87 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5186.55 | 3443.73 | 1742.82 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5018.59 | 3309.14 | 1709.44 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4349.83 | 2827.95 | 1521.89 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3196.64 | 2041.61 | 1155.03 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3179.28 | 2028.95 | 1150.33 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3693.53 | 2396.61 | 1296.92 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3704.06 | 2404.55 | 1299.51 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5635.34 | 3769.15 | 1866.19 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5362.55 | 3566.82 | 1795.73 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5166.14 | 3410.89 | 1755.25 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4448.79 | 2893.36 | 1555.43 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3344.92 | 2146.15 | 1198.77 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3327.41 | 2133.34 | 1194.07 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3813.81 | 2480.89 | 1332.91 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3823.95 | 2488.56 | 1335.39 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6706.89 | 4567.38 | 2139.51 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6326.19 | 4282.86 | 2043.33 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6166.78 | 4156.87 | 2009.91 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5304.64 | 3520.49 | 1784.15 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4146.95 | 2726.04 | 1420.91 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4142.53 | 2722.90 | 1419.64 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4916.02 | 3308.15 | 1607.87 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4925.75 | 3315.64 | 1610.11 | 0.67 | 0.00 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
None |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
HEAT PUMP HEATING MODE AIRLOOP G SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4068.34 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 3852.75 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP OFFICE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5969.90 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3125.32 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2341.16 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2319.26 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2748.20 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2835.58 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5089.12 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4813.92 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4949.47 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3988.74 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2943.25 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2925.58 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3436.13 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3466.69 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5194.08 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4925.64 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4775.27 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4110.79 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3034.20 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3016.63 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3529.69 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3543.01 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5282.11 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5006.65 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4832.38 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4184.98 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3090.28 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3072.72 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3586.35 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3597.21 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5378.50 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5102.44 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4927.95 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4283.46 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3164.21 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3146.69 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3660.25 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3670.77 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5385.45 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5111.59 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4936.97 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4283.98 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3151.76 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3134.29 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3649.20 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3659.69 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5415.98 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5141.65 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4969.42 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4309.83 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3165.69 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3148.25 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3663.51 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3674.01 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5461.03 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5186.55 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5018.59 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4349.83 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3196.64 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3179.28 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3693.53 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3704.06 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5635.34 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5362.55 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5166.14 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4448.79 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3344.92 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3327.41 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3813.81 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3823.95 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 6706.89 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 6326.19 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 6166.78 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5304.64 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4146.95 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4142.53 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4916.02 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4925.75 | 0.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW | Coil:Heating:Electric | 3554.23 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW | Coil:Heating:Electric | 3556.67 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE | Coil:Heating:Electric | 4397.18 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE | Coil:Heating:Electric | 3559.11 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 | Coil:Heating:Electric | 2688.13 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 | Coil:Heating:Electric | 2688.18 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 | Coil:Heating:Electric | 2682.34 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 | Coil:Heating:Electric | 2688.67 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW | Coil:Heating:Electric | 3559.06 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW | Coil:Heating:Electric | 3558.84 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE | Coil:Heating:Electric | 3577.66 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE | Coil:Heating:Electric | 3558.96 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 | Coil:Heating:Electric | 2466.31 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 | Coil:Heating:Electric | 2466.32 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 | Coil:Heating:Electric | 2469.33 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 | Coil:Heating:Electric | 2470.53 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW | Coil:Heating:Electric | 3633.94 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW | Coil:Heating:Electric | 3637.88 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE | Coil:Heating:Electric | 3634.13 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE | Coil:Heating:Electric | 3636.07 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 | Coil:Heating:Electric | 2473.05 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 | Coil:Heating:Electric | 2473.00 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 | Coil:Heating:Electric | 2469.93 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 | Coil:Heating:Electric | 2470.07 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW | Coil:Heating:Electric | 3748.75 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW | Coil:Heating:Electric | 3755.50 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE | Coil:Heating:Electric | 3745.71 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE | Coil:Heating:Electric | 3752.25 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 | Coil:Heating:Electric | 2533.53 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 | Coil:Heating:Electric | 2533.45 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 | Coil:Heating:Electric | 2527.29 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 | Coil:Heating:Electric | 2527.23 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW | Coil:Heating:Electric | 3832.84 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW | Coil:Heating:Electric | 3840.48 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE | Coil:Heating:Electric | 3828.49 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE | Coil:Heating:Electric | 3836.10 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 | Coil:Heating:Electric | 2573.04 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 | Coil:Heating:Electric | 2572.93 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 | Coil:Heating:Electric | 2565.80 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 | Coil:Heating:Electric | 2565.70 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW | Coil:Heating:Electric | 3966.63 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW | Coil:Heating:Electric | 3976.66 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE | Coil:Heating:Electric | 3961.31 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE | Coil:Heating:Electric | 3971.34 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 | Coil:Heating:Electric | 2668.07 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 | Coil:Heating:Electric | 2667.94 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 | Coil:Heating:Electric | 2658.44 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 | Coil:Heating:Electric | 2658.31 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW | Coil:Heating:Electric | 4068.57 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW | Coil:Heating:Electric | 4079.63 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE | Coil:Heating:Electric | 4062.45 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE | Coil:Heating:Electric | 4073.52 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 | Coil:Heating:Electric | 2735.99 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 | Coil:Heating:Electric | 2735.84 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 | Coil:Heating:Electric | 2725.31 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 | Coil:Heating:Electric | 2725.16 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW | Coil:Heating:Electric | 4170.66 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW | Coil:Heating:Electric | 4182.34 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE | Coil:Heating:Electric | 4163.85 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE | Coil:Heating:Electric | 4175.53 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 | Coil:Heating:Electric | 2807.41 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 | Coil:Heating:Electric | 2807.24 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 | Coil:Heating:Electric | 2796.09 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 | Coil:Heating:Electric | 2795.93 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW | Coil:Heating:Electric | 4395.73 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW | Coil:Heating:Electric | 4405.55 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE | Coil:Heating:Electric | 4388.24 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE | Coil:Heating:Electric | 4398.07 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 | Coil:Heating:Electric | 2993.63 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 | Coil:Heating:Electric | 2993.45 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 | Coil:Heating:Electric | 2983.73 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 | Coil:Heating:Electric | 2983.55 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW | Coil:Heating:Electric | 5073.45 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW | Coil:Heating:Electric | 5089.95 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE | Coil:Heating:Electric | 5066.06 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE | Coil:Heating:Electric | 5082.56 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 | Coil:Heating:Electric | 3709.98 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 | Coil:Heating:Electric | 3709.78 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 | Coil:Heating:Electric | 3690.38 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 | Coil:Heating:Electric | 3690.19 | 1.00 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
AIRLOOP G SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 254.48 | 1160.84 | 1.00 | General |
AIRLOOP G NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 238.82 | 1160.84 | 1.00 | General |
AIRLOOP OFFICE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 381.84 | 1160.84 | 1.00 | General |
AIRLOOP G NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 183.23 | 1160.84 | 1.00 | General |
AIRLOOP G N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.11 | 126.43 | 1160.84 | 1.00 | General |
AIRLOOP G N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.11 | 124.75 | 1160.84 | 1.00 | General |
AIRLOOP G S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.13 | 153.55 | 1160.84 | 1.00 | General |
AIRLOOP G S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.14 | 160.52 | 1160.84 | 1.00 | General |
AIRLOOP F2 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 329.39 | 1160.84 | 1.00 | General |
AIRLOOP F2 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 308.35 | 1160.84 | 1.00 | General |
AIRLOOP F2 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 316.05 | 1160.84 | 1.00 | General |
AIRLOOP F2 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 244.85 | 1160.84 | 1.00 | General |
AIRLOOP F2 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 169.64 | 1160.84 | 1.00 | General |
AIRLOOP F2 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.14 | 168.26 | 1160.84 | 1.00 | General |
AIRLOOP F2 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 204.04 | 1160.84 | 1.00 | General |
AIRLOOP F2 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 206.50 | 1160.84 | 1.00 | General |
AIRLOOP F3 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.29 | 333.04 | 1160.84 | 1.00 | General |
AIRLOOP F3 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 312.64 | 1160.84 | 1.00 | General |
AIRLOOP F3 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.26 | 297.34 | 1160.84 | 1.00 | General |
AIRLOOP F3 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 250.22 | 1160.84 | 1.00 | General |
AIRLOOP F3 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 174.36 | 1160.84 | 1.00 | General |
AIRLOOP F3 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 172.99 | 1160.84 | 1.00 | General |
AIRLOOP F3 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 208.86 | 1160.84 | 1.00 | General |
AIRLOOP F3 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 209.94 | 1160.84 | 1.00 | General |
AIRLOOP F4 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.29 | 336.11 | 1160.84 | 1.00 | General |
AIRLOOP F4 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 315.66 | 1160.84 | 1.00 | General |
AIRLOOP F4 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.26 | 298.51 | 1160.84 | 1.00 | General |
AIRLOOP F4 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 252.91 | 1160.84 | 1.00 | General |
AIRLOOP F4 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 176.95 | 1160.84 | 1.00 | General |
AIRLOOP F4 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 175.60 | 1160.84 | 1.00 | General |
AIRLOOP F4 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 211.40 | 1160.84 | 1.00 | General |
AIRLOOP F4 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 212.27 | 1160.84 | 1.00 | General |
AIRLOOP M SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.29 | 340.97 | 1160.84 | 1.00 | General |
AIRLOOP M NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 320.52 | 1160.84 | 1.00 | General |
AIRLOOP M SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.26 | 303.39 | 1160.84 | 1.00 | General |
AIRLOOP M NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 257.46 | 1160.84 | 1.00 | General |
AIRLOOP M N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 181.27 | 1160.84 | 1.00 | General |
AIRLOOP M N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 179.92 | 1160.84 | 1.00 | General |
AIRLOOP M S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 215.67 | 1160.84 | 1.00 | General |
AIRLOOP M S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 216.51 | 1160.84 | 1.00 | General |
AIRLOOP F6 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.29 | 339.10 | 1160.84 | 1.00 | General |
AIRLOOP F6 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 318.55 | 1160.84 | 1.00 | General |
AIRLOOP F6 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.26 | 301.80 | 1160.84 | 1.00 | General |
AIRLOOP F6 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 255.36 | 1160.84 | 1.00 | General |
AIRLOOP F6 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 179.08 | 1160.84 | 1.00 | General |
AIRLOOP F6 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 177.74 | 1160.84 | 1.00 | General |
AIRLOOP F6 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 213.44 | 1160.84 | 1.00 | General |
AIRLOOP F6 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 214.28 | 1160.84 | 1.00 | General |
AIRLOOP F7 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.29 | 339.42 | 1160.84 | 1.00 | General |
AIRLOOP F7 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 318.90 | 1160.84 | 1.00 | General |
AIRLOOP F7 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.26 | 302.37 | 1160.84 | 1.00 | General |
AIRLOOP F7 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 255.53 | 1160.84 | 1.00 | General |
AIRLOOP F7 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 179.11 | 1160.84 | 1.00 | General |
AIRLOOP F7 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 177.78 | 1160.84 | 1.00 | General |
AIRLOOP F7 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 213.39 | 1160.84 | 1.00 | General |
AIRLOOP F7 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 214.23 | 1160.84 | 1.00 | General |
AIRLOOP F8 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.29 | 341.13 | 1160.84 | 1.00 | General |
AIRLOOP F8 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 320.64 | 1160.84 | 1.00 | General |
AIRLOOP F8 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.26 | 304.26 | 1160.84 | 1.00 | General |
AIRLOOP F8 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 257.01 | 1160.84 | 1.00 | General |
AIRLOOP F8 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 180.56 | 1160.84 | 1.00 | General |
AIRLOOP F8 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 179.24 | 1160.84 | 1.00 | General |
AIRLOOP F8 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 214.71 | 1160.84 | 1.00 | General |
AIRLOOP F8 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 215.56 | 1160.84 | 1.00 | General |
AIRLOOP F9 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 353.29 | 1160.84 | 1.00 | General |
AIRLOOP F9 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.29 | 332.91 | 1160.84 | 1.00 | General |
AIRLOOP F9 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 314.27 | 1160.84 | 1.00 | General |
AIRLOOP F9 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 263.19 | 1160.84 | 1.00 | General |
AIRLOOP F9 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 191.13 | 1160.84 | 1.00 | General |
AIRLOOP F9 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 189.79 | 1160.84 | 1.00 | General |
AIRLOOP F9 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 223.02 | 1160.84 | 1.00 | General |
AIRLOOP F9 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 223.84 | 1160.84 | 1.00 | General |
AIRLOOP T SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.38 | 436.15 | 1160.84 | 1.00 | General |
AIRLOOP T NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.35 | 406.99 | 1160.84 | 1.00 | General |
AIRLOOP T SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.34 | 392.58 | 1160.84 | 1.00 | General |
AIRLOOP T NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 328.14 | 1160.84 | 1.00 | General |
AIRLOOP T N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 248.49 | 1160.84 | 1.00 | General |
AIRLOOP T N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 248.17 | 1160.84 | 1.00 | General |
AIRLOOP T S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 310.19 | 1160.84 | 1.00 | General |
AIRLOOP T S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 310.99 | 1160.84 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
SHWSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.0003 | 36.93 | 127739.32 | 0.30 |
PLANT CIRC PUMP | Pump:ConstantSpeed | Intermittent | 224180.02 | 0.0073 | 2337.93 | 319344.75 | 0.90 |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SHWSYS1 WATER HEATER | WaterHeater:Mixed | 2.27 | 175842.64 | 0.80 | 0.00 | 0.00 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 2320.44 | 2784.53 | 0.183 | 0.219 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 33.36 | 0.01446 |
G NW APARTMENT | 2177.72 | 2613.26 | 0.171 | 0.206 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 32.16 | 0.01446 |
OFFICE | 3481.74 | 4178.08 | 0.274 | 0.329 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 34.14 | 0.01446 |
G NE APARTMENT | 1670.68 | 2004.81 | 0.132 | 0.158 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 31.23 | 0.01446 |
G N1 APARTMENT | 1152.91 | 1383.49 | 0.091 | 0.109 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 31.12 | 0.01446 |
G N2 APARTMENT | 1137.62 | 1365.14 | 0.090 | 0.107 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 31.12 | 0.01446 |
G S1 APARTMENT | 1400.13 | 1680.16 | 0.110 | 0.132 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.27 | 0.01446 |
G S2 APARTMENT | 1463.73 | 1756.48 | 0.115 | 0.138 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.27 | 0.01446 |
F2 SW APARTMENT | 3003.36 | 3604.04 | 0.236 | 0.284 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 33.15 | 0.01446 |
F2 NW APARTMENT | 2811.66 | 3373.99 | 0.221 | 0.266 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 32.16 | 0.01446 |
F2 SE APARTMENT | 2881.73 | 3458.08 | 0.227 | 0.272 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 34.14 | 0.01446 |
F2 NE APARTMENT | 2232.52 | 2679.02 | 0.176 | 0.211 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 31.23 | 0.01446 |
F2 N1 APARTMENT | 1546.87 | 1856.25 | 0.122 | 0.146 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 31.12 | 0.01446 |
F2 N2 APARTMENT | 1534.32 | 1841.19 | 0.121 | 0.145 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 31.12 | 0.01446 |
F2 S1 APARTMENT | 1860.56 | 2232.67 | 0.146 | 0.176 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.27 | 0.01446 |
F2 S2 APARTMENT | 1883.00 | 2259.60 | 0.148 | 0.178 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.27 | 0.01446 |
F3 SW APARTMENT | 3036.55 | 3643.86 | 0.239 | 0.287 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 33.15 | 0.01446 |
F3 NW APARTMENT | 2850.66 | 3420.79 | 0.224 | 0.269 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 32.16 | 0.01446 |
F3 SE APARTMENT | 2711.01 | 3253.21 | 0.213 | 0.256 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 34.14 | 0.01446 |
F3 NE APARTMENT | 2281.44 | 2737.72 | 0.180 | 0.216 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 31.23 | 0.01446 |
F3 N1 APARTMENT | 1589.89 | 1907.87 | 0.125 | 0.150 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 31.12 | 0.01446 |
F3 N2 APARTMENT | 1577.47 | 1892.96 | 0.124 | 0.149 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 31.12 | 0.01446 |
F3 S1 APARTMENT | 1904.46 | 2285.35 | 0.150 | 0.180 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.27 | 0.01446 |
F3 S2 APARTMENT | 1914.27 | 2297.12 | 0.151 | 0.181 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.27 | 0.01446 |
F4 SW APARTMENT | 3064.48 | 3677.38 | 0.241 | 0.290 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 33.36 | 0.01446 |
F4 NW APARTMENT | 2878.20 | 3453.85 | 0.227 | 0.272 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 32.16 | 0.01446 |
F4 SE APARTMENT | 2721.62 | 3265.95 | 0.214 | 0.257 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 34.14 | 0.01446 |
F4 NE APARTMENT | 2305.86 | 2767.04 | 0.182 | 0.218 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 31.23 | 0.01446 |
F4 N1 APARTMENT | 1613.54 | 1936.25 | 0.127 | 0.152 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 31.12 | 0.01446 |
F4 N2 APARTMENT | 1601.18 | 1921.41 | 0.126 | 0.151 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 31.12 | 0.01446 |
F4 S1 APARTMENT | 1927.54 | 2313.05 | 0.152 | 0.182 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.27 | 0.01446 |
F4 S2 APARTMENT | 1935.54 | 2322.65 | 0.152 | 0.183 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.27 | 0.01446 |
M SW APARTMENT | 3108.74 | 3730.49 | 0.245 | 0.294 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 33.36 | 0.01446 |
M NW APARTMENT | 2922.48 | 3506.97 | 0.230 | 0.276 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 32.16 | 0.01446 |
M SE APARTMENT | 2766.09 | 3319.31 | 0.218 | 0.261 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 34.14 | 0.01446 |
M NE APARTMENT | 2347.36 | 2816.83 | 0.185 | 0.222 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 31.62 | 0.01446 |
M N1 APARTMENT | 1652.90 | 1983.48 | 0.130 | 0.156 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 31.12 | 0.01446 |
M N2 APARTMENT | 1640.58 | 1968.69 | 0.129 | 0.155 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 31.12 | 0.01446 |
M S1 APARTMENT | 1966.45 | 2359.74 | 0.155 | 0.186 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.27 | 0.01446 |
M S2 APARTMENT | 1974.18 | 2369.02 | 0.155 | 0.187 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.27 | 0.01446 |
F6 SW APARTMENT | 3091.59 | 3709.91 | 0.243 | 0.292 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 33.36 | 0.01446 |
F6 NW APARTMENT | 2904.45 | 3485.35 | 0.229 | 0.274 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 32.42 | 0.01446 |
F6 SE APARTMENT | 2751.57 | 3301.89 | 0.217 | 0.260 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 34.14 | 0.01446 |
F6 NE APARTMENT | 2328.14 | 2793.77 | 0.183 | 0.220 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 31.62 | 0.01446 |
F6 N1 APARTMENT | 1632.97 | 1959.56 | 0.129 | 0.154 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 31.12 | 0.01446 |
F6 N2 APARTMENT | 1620.74 | 1944.89 | 0.128 | 0.153 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 31.12 | 0.01446 |
F6 S1 APARTMENT | 1946.09 | 2335.31 | 0.153 | 0.184 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.27 | 0.01446 |
F6 S2 APARTMENT | 1953.79 | 2344.55 | 0.154 | 0.185 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.27 | 0.01446 |
F7 SW APARTMENT | 3094.53 | 3713.43 | 0.244 | 0.292 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 33.36 | 0.01446 |
F7 NW APARTMENT | 2907.56 | 3489.07 | 0.229 | 0.275 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 32.42 | 0.01446 |
F7 SE APARTMENT | 2756.76 | 3308.11 | 0.217 | 0.260 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 34.14 | 0.01446 |
F7 NE APARTMENT | 2329.66 | 2795.59 | 0.183 | 0.220 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 31.62 | 0.01446 |
F7 N1 APARTMENT | 1633.20 | 1959.84 | 0.129 | 0.154 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 31.12 | 0.01446 |
F7 N2 APARTMENT | 1621.04 | 1945.25 | 0.128 | 0.153 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 31.12 | 0.01446 |
F7 S1 APARTMENT | 1945.67 | 2334.81 | 0.153 | 0.184 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.27 | 0.01446 |
F7 S2 APARTMENT | 1953.36 | 2344.03 | 0.154 | 0.185 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.27 | 0.01446 |
F8 SW APARTMENT | 3110.10 | 3732.12 | 0.245 | 0.294 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 33.36 | 0.01446 |
F8 NW APARTMENT | 2923.42 | 3508.10 | 0.230 | 0.276 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 32.42 | 0.01446 |
F8 SE APARTMENT | 2773.93 | 3328.71 | 0.218 | 0.262 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.27 | 0.01446 |
F8 NE APARTMENT | 2343.11 | 2811.74 | 0.184 | 0.221 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 31.62 | 0.01446 |
F8 N1 APARTMENT | 1646.45 | 1975.74 | 0.130 | 0.156 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 31.12 | 0.01446 |
F8 N2 APARTMENT | 1634.37 | 1961.24 | 0.129 | 0.154 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 31.12 | 0.01446 |
F8 S1 APARTMENT | 1957.70 | 2349.24 | 0.154 | 0.185 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.27 | 0.01446 |
F8 S2 APARTMENT | 1965.39 | 2358.47 | 0.155 | 0.186 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.27 | 0.01446 |
F9 SW APARTMENT | 3220.91 | 3865.09 | 0.254 | 0.304 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 33.36 | 0.01446 |
F9 NW APARTMENT | 3035.28 | 3642.34 | 0.239 | 0.287 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 32.42 | 0.01446 |
F9 SE APARTMENT | 2865.13 | 3438.16 | 0.226 | 0.271 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.27 | 0.01446 |
F9 NE APARTMENT | 2399.47 | 2879.37 | 0.189 | 0.227 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 31.62 | 0.01446 |
F9 N1 APARTMENT | 1742.82 | 2091.39 | 0.137 | 0.165 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 31.12 | 0.01446 |
F9 N2 APARTMENT | 1730.59 | 2076.71 | 0.136 | 0.163 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 31.12 | 0.01446 |
F9 S1 APARTMENT | 2033.47 | 2440.16 | 0.160 | 0.192 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 34.40 | 0.01446 |
F9 S2 APARTMENT | 2040.90 | 2449.08 | 0.161 | 0.193 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 34.40 | 0.01446 |
T SW APARTMENT | 3976.15 | 4771.38 | 0.313 | 0.376 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 | 34.09 | 0.01446 |
T NW APARTMENT | 3710.32 | 4452.38 | 0.292 | 0.351 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 33.36 | 0.01446 |
T SE APARTMENT | 3579.00 | 4294.80 | 0.282 | 0.338 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 34.14 | 0.01446 |
T NE APARTMENT | 2991.44 | 3589.73 | 0.236 | 0.283 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 32.01 | 0.01446 |
T N1 APARTMENT | 2265.59 | 2718.71 | 0.178 | 0.214 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 34.40 | 0.01446 |
T N2 APARTMENT | 2262.69 | 2715.23 | 0.178 | 0.214 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 34.40 | 0.01446 |
T S1 APARTMENT | 2828.20 | 3393.84 | 0.223 | 0.267 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.27 | 0.01446 |
T S2 APARTMENT | 2835.50 | 3402.60 | 0.223 | 0.268 | BALTIMORE BLT WASHNGTN INTL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.27 | 0.01446 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 2152.38 | 2582.86 | 0.096 | 0.116 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -10.60 | 0.00152 |
G NW APARTMENT | 2154.45 | 2585.34 | 0.096 | 0.116 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -10.60 | 0.00152 |
OFFICE | 2465.74 | 2958.89 | 0.110 | 0.132 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 18:45:00 | -10.60 | 0.00152 |
G NE APARTMENT | 2156.51 | 2587.81 | 0.096 | 0.116 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -10.60 | 0.00152 |
G N1 APARTMENT | 1419.95 | 1703.94 | 0.064 | 0.076 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -10.60 | 0.00152 |
G N2 APARTMENT | 1419.99 | 1703.99 | 0.064 | 0.076 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -10.60 | 0.00152 |
G S1 APARTMENT | 1415.06 | 1698.07 | 0.063 | 0.076 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -10.60 | 0.00152 |
G S2 APARTMENT | 1420.41 | 1704.49 | 0.064 | 0.076 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -10.60 | 0.00152 |
F2 SW APARTMENT | 2156.52 | 2587.82 | 0.096 | 0.116 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F2 NW APARTMENT | 2156.33 | 2587.60 | 0.096 | 0.116 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F2 SE APARTMENT | 2172.25 | 2606.70 | 0.097 | 0.117 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F2 NE APARTMENT | 2156.43 | 2587.72 | 0.096 | 0.116 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F2 N1 APARTMENT | 1232.40 | 1478.88 | 0.055 | 0.066 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F2 N2 APARTMENT | 1232.41 | 1478.89 | 0.055 | 0.066 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F2 S1 APARTMENT | 1234.95 | 1481.94 | 0.055 | 0.066 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F2 S2 APARTMENT | 1235.96 | 1483.16 | 0.055 | 0.066 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F3 SW APARTMENT | 2219.86 | 2663.83 | 0.099 | 0.119 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F3 NW APARTMENT | 2223.18 | 2667.82 | 0.099 | 0.119 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F3 SE APARTMENT | 2220.01 | 2664.01 | 0.099 | 0.119 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F3 NE APARTMENT | 2221.65 | 2665.98 | 0.099 | 0.119 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F3 N1 APARTMENT | 1238.11 | 1485.73 | 0.055 | 0.066 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F3 N2 APARTMENT | 1238.07 | 1485.68 | 0.055 | 0.066 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F3 S1 APARTMENT | 1235.47 | 1482.56 | 0.055 | 0.066 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F3 S2 APARTMENT | 1235.59 | 1482.70 | 0.055 | 0.066 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F4 SW APARTMENT | 2316.95 | 2780.34 | 0.104 | 0.124 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F4 NW APARTMENT | 2322.66 | 2787.19 | 0.104 | 0.125 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F4 SE APARTMENT | 2314.38 | 2777.25 | 0.104 | 0.124 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F4 NE APARTMENT | 2319.91 | 2783.90 | 0.104 | 0.125 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F4 N1 APARTMENT | 1289.26 | 1547.11 | 0.058 | 0.069 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F4 N2 APARTMENT | 1289.19 | 1547.03 | 0.058 | 0.069 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F4 S1 APARTMENT | 1283.98 | 1540.78 | 0.057 | 0.069 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F4 S2 APARTMENT | 1283.94 | 1540.72 | 0.057 | 0.069 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
M SW APARTMENT | 2388.07 | 2865.69 | 0.107 | 0.128 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
M NW APARTMENT | 2394.53 | 2873.44 | 0.107 | 0.129 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
M SE APARTMENT | 2384.39 | 2861.26 | 0.107 | 0.128 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
M NE APARTMENT | 2390.83 | 2869.00 | 0.107 | 0.128 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
M N1 APARTMENT | 1322.68 | 1587.21 | 0.059 | 0.071 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
M N2 APARTMENT | 1322.59 | 1587.10 | 0.059 | 0.071 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
M S1 APARTMENT | 1316.56 | 1579.87 | 0.059 | 0.071 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
M S2 APARTMENT | 1316.47 | 1579.76 | 0.059 | 0.071 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F6 SW APARTMENT | 2501.21 | 3001.46 | 0.112 | 0.134 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F6 NW APARTMENT | 2509.69 | 3011.63 | 0.112 | 0.135 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F6 SE APARTMENT | 2496.72 | 2996.06 | 0.112 | 0.134 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F6 NE APARTMENT | 2505.20 | 3006.24 | 0.112 | 0.134 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F6 N1 APARTMENT | 1403.05 | 1683.66 | 0.063 | 0.075 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F6 N2 APARTMENT | 1402.94 | 1683.52 | 0.063 | 0.075 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F6 S1 APARTMENT | 1394.90 | 1673.88 | 0.062 | 0.075 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F6 S2 APARTMENT | 1394.79 | 1673.75 | 0.062 | 0.075 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F7 SW APARTMENT | 2587.43 | 3104.91 | 0.116 | 0.139 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F7 NW APARTMENT | 2596.78 | 3116.14 | 0.116 | 0.139 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F7 SE APARTMENT | 2582.25 | 3098.70 | 0.115 | 0.139 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F7 NE APARTMENT | 2591.61 | 3109.93 | 0.116 | 0.139 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F7 N1 APARTMENT | 1460.48 | 1752.58 | 0.065 | 0.078 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F7 N2 APARTMENT | 1460.35 | 1752.42 | 0.065 | 0.078 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F7 S1 APARTMENT | 1451.45 | 1741.74 | 0.065 | 0.078 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F7 S2 APARTMENT | 1451.32 | 1741.59 | 0.065 | 0.078 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F8 SW APARTMENT | 2673.76 | 3208.52 | 0.120 | 0.143 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F8 NW APARTMENT | 2683.64 | 3220.37 | 0.120 | 0.144 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F8 SE APARTMENT | 2668.00 | 3201.60 | 0.119 | 0.143 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F8 NE APARTMENT | 2677.88 | 3213.46 | 0.120 | 0.144 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F8 N1 APARTMENT | 1520.88 | 1825.06 | 0.068 | 0.082 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F8 N2 APARTMENT | 1520.74 | 1824.89 | 0.068 | 0.082 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F8 S1 APARTMENT | 1511.31 | 1813.58 | 0.068 | 0.081 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F8 S2 APARTMENT | 1511.17 | 1813.41 | 0.068 | 0.081 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F9 SW APARTMENT | 2864.10 | 3436.92 | 0.128 | 0.154 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F9 NW APARTMENT | 2872.41 | 3446.89 | 0.128 | 0.154 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F9 SE APARTMENT | 2857.77 | 3429.32 | 0.128 | 0.153 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F9 NE APARTMENT | 2866.08 | 3439.29 | 0.128 | 0.154 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F9 N1 APARTMENT | 1678.36 | 2014.03 | 0.075 | 0.090 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F9 N2 APARTMENT | 1678.21 | 2013.85 | 0.075 | 0.090 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F9 S1 APARTMENT | 1669.99 | 2003.99 | 0.075 | 0.090 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
F9 S2 APARTMENT | 1669.84 | 2003.81 | 0.075 | 0.090 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
T SW APARTMENT | 3437.23 | 4124.67 | 0.154 | 0.184 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
T NW APARTMENT | 3451.18 | 4141.42 | 0.154 | 0.185 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
T SE APARTMENT | 3430.98 | 4117.18 | 0.153 | 0.184 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
T NE APARTMENT | 3444.94 | 4133.92 | 0.154 | 0.185 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
T N1 APARTMENT | 2284.15 | 2740.98 | 0.102 | 0.123 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
T N2 APARTMENT | 2283.99 | 2740.79 | 0.102 | 0.123 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
T S1 APARTMENT | 2267.58 | 2721.10 | 0.101 | 0.122 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
T S2 APARTMENT | 2267.42 | 2720.90 | 0.101 | 0.122 | BALTIMORE BLT WASHNGTN INTL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -10.60 | 0.00152 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
AIRLOOP G SW | 0.22 | 0.22 | 0.12 | 0.12 |
AIRLOOP G NW | 0.21 | 0.21 | 0.12 | 0.12 |
AIRLOOP OFFICE | 0.33 | 0.33 | 0.13 | 0.13 |
AIRLOOP G NE | 0.16 | 0.16 | 0.12 | 0.12 |
AIRLOOP G N1 | 0.11 | 0.11 | 0.08 | 0.08 |
AIRLOOP G N2 | 0.11 | 0.11 | 0.08 | 0.08 |
AIRLOOP G S1 | 0.13 | 0.13 | 0.08 | 0.08 |
AIRLOOP G S2 | 0.14 | 0.14 | 0.08 | 0.08 |
AIRLOOP F2 SW | 0.28 | 0.28 | 0.12 | 0.12 |
AIRLOOP F2 NW | 0.27 | 0.27 | 0.12 | 0.12 |
AIRLOOP F2 SE | 0.27 | 0.27 | 0.12 | 0.12 |
AIRLOOP F2 NE | 0.21 | 0.21 | 0.12 | 0.12 |
AIRLOOP F2 N1 | 0.15 | 0.15 | 0.07 | 0.07 |
AIRLOOP F2 N2 | 0.14 | 0.14 | 0.07 | 0.07 |
AIRLOOP F2 S1 | 0.18 | 0.18 | 0.07 | 0.07 |
AIRLOOP F2 S2 | 0.18 | 0.18 | 0.07 | 0.07 |
AIRLOOP F3 SW | 0.29 | 0.29 | 0.12 | 0.12 |
AIRLOOP F3 NW | 0.27 | 0.27 | 0.12 | 0.12 |
AIRLOOP F3 SE | 0.26 | 0.26 | 0.12 | 0.12 |
AIRLOOP F3 NE | 0.22 | 0.22 | 0.12 | 0.12 |
AIRLOOP F3 N1 | 0.15 | 0.15 | 0.07 | 0.07 |
AIRLOOP F3 N2 | 0.15 | 0.15 | 0.07 | 0.07 |
AIRLOOP F3 S1 | 0.18 | 0.18 | 0.07 | 0.07 |
AIRLOOP F3 S2 | 0.18 | 0.18 | 0.07 | 0.07 |
AIRLOOP F4 SW | 0.29 | 0.29 | 0.12 | 0.12 |
AIRLOOP F4 NW | 0.27 | 0.27 | 0.12 | 0.12 |
AIRLOOP F4 SE | 0.26 | 0.26 | 0.12 | 0.12 |
AIRLOOP F4 NE | 0.22 | 0.22 | 0.12 | 0.12 |
AIRLOOP F4 N1 | 0.15 | 0.15 | 0.07 | 0.07 |
AIRLOOP F4 N2 | 0.15 | 0.15 | 0.07 | 0.07 |
AIRLOOP F4 S1 | 0.18 | 0.18 | 0.07 | 0.07 |
AIRLOOP F4 S2 | 0.18 | 0.18 | 0.07 | 0.07 |
AIRLOOP M SW | 0.29 | 0.29 | 0.13 | 0.13 |
AIRLOOP M NW | 0.28 | 0.28 | 0.13 | 0.13 |
AIRLOOP M SE | 0.26 | 0.26 | 0.13 | 0.13 |
AIRLOOP M NE | 0.22 | 0.22 | 0.13 | 0.13 |
AIRLOOP M N1 | 0.16 | 0.16 | 0.07 | 0.07 |
AIRLOOP M N2 | 0.15 | 0.15 | 0.07 | 0.07 |
AIRLOOP M S1 | 0.19 | 0.19 | 0.07 | 0.07 |
AIRLOOP M S2 | 0.19 | 0.19 | 0.07 | 0.07 |
AIRLOOP F6 SW | 0.29 | 0.29 | 0.13 | 0.13 |
AIRLOOP F6 NW | 0.27 | 0.27 | 0.13 | 0.13 |
AIRLOOP F6 SE | 0.26 | 0.26 | 0.13 | 0.13 |
AIRLOOP F6 NE | 0.22 | 0.22 | 0.13 | 0.13 |
AIRLOOP F6 N1 | 0.15 | 0.15 | 0.08 | 0.08 |
AIRLOOP F6 N2 | 0.15 | 0.15 | 0.08 | 0.08 |
AIRLOOP F6 S1 | 0.18 | 0.18 | 0.07 | 0.07 |
AIRLOOP F6 S2 | 0.18 | 0.18 | 0.07 | 0.07 |
AIRLOOP F7 SW | 0.29 | 0.29 | 0.14 | 0.14 |
AIRLOOP F7 NW | 0.27 | 0.27 | 0.14 | 0.14 |
AIRLOOP F7 SE | 0.26 | 0.26 | 0.14 | 0.14 |
AIRLOOP F7 NE | 0.22 | 0.22 | 0.14 | 0.14 |
AIRLOOP F7 N1 | 0.15 | 0.15 | 0.08 | 0.08 |
AIRLOOP F7 N2 | 0.15 | 0.15 | 0.08 | 0.08 |
AIRLOOP F7 S1 | 0.18 | 0.18 | 0.08 | 0.08 |
AIRLOOP F7 S2 | 0.18 | 0.18 | 0.08 | 0.08 |
AIRLOOP F8 SW | 0.29 | 0.29 | 0.14 | 0.14 |
AIRLOOP F8 NW | 0.28 | 0.28 | 0.14 | 0.14 |
AIRLOOP F8 SE | 0.26 | 0.26 | 0.14 | 0.14 |
AIRLOOP F8 NE | 0.22 | 0.22 | 0.14 | 0.14 |
AIRLOOP F8 N1 | 0.16 | 0.16 | 0.08 | 0.08 |
AIRLOOP F8 N2 | 0.15 | 0.15 | 0.08 | 0.08 |
AIRLOOP F8 S1 | 0.18 | 0.18 | 0.08 | 0.08 |
AIRLOOP F8 S2 | 0.19 | 0.19 | 0.08 | 0.08 |
AIRLOOP F9 SW | 0.30 | 0.30 | 0.15 | 0.15 |
AIRLOOP F9 NW | 0.29 | 0.29 | 0.15 | 0.15 |
AIRLOOP F9 SE | 0.27 | 0.27 | 0.15 | 0.15 |
AIRLOOP F9 NE | 0.23 | 0.23 | 0.15 | 0.15 |
AIRLOOP F9 N1 | 0.16 | 0.16 | 0.09 | 0.09 |
AIRLOOP F9 N2 | 0.16 | 0.16 | 0.09 | 0.09 |
AIRLOOP F9 S1 | 0.19 | 0.19 | 0.09 | 0.09 |
AIRLOOP F9 S2 | 0.19 | 0.19 | 0.09 | 0.09 |
AIRLOOP T SW | 0.38 | 0.38 | 0.18 | 0.18 |
AIRLOOP T NW | 0.35 | 0.35 | 0.19 | 0.19 |
AIRLOOP T SE | 0.34 | 0.34 | 0.18 | 0.18 |
AIRLOOP T NE | 0.28 | 0.28 | 0.18 | 0.18 |
AIRLOOP T N1 | 0.21 | 0.21 | 0.12 | 0.12 |
AIRLOOP T N2 | 0.21 | 0.21 | 0.12 | 0.12 |
AIRLOOP T S1 | 0.27 | 0.27 | 0.12 | 0.12 |
AIRLOOP T S2 | 0.27 | 0.27 | 0.12 | 0.12 |
Report: System Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 3446.75 | 6190.75 | 1356.75 |
G NW APARTMENT | 3715.75 | 6605.25 | 1853.25 |
OFFICE | 1066.75 | 797.75 | 14.25 |
G NE APARTMENT | 3717.25 | 6585.50 | 1798.75 |
G N1 APARTMENT | 3274.00 | 6800.50 | 1578.75 |
G N2 APARTMENT | 3275.00 | 6802.75 | 1577.50 |
G S1 APARTMENT | 3122.00 | 6334.00 | 1171.50 |
G S2 APARTMENT | 3142.00 | 6268.25 | 1150.00 |
F2 SW APARTMENT | 3806.25 | 4816.50 | 770.00 |
F2 NW APARTMENT | 3723.50 | 5618.25 | 1116.75 |
F2 SE APARTMENT | 3943.75 | 4511.25 | 676.00 |
F2 NE APARTMENT | 3685.50 | 5674.25 | 1095.75 |
F2 N1 APARTMENT | 3294.00 | 5912.00 | 863.25 |
F2 N2 APARTMENT | 3293.50 | 5923.25 | 868.00 |
F2 S1 APARTMENT | 3616.00 | 4858.25 | 691.75 |
F2 S2 APARTMENT | 3638.50 | 4802.75 | 687.25 |
F3 SW APARTMENT | 3939.50 | 4624.50 | 764.00 |
F3 NW APARTMENT | 3786.50 | 5451.50 | 1076.75 |
F3 SE APARTMENT | 3968.75 | 4562.25 | 721.25 |
F3 NE APARTMENT | 3725.75 | 5480.50 | 1046.00 |
F3 N1 APARTMENT | 3388.50 | 5632.75 | 815.50 |
F3 N2 APARTMENT | 3383.50 | 5644.00 | 815.00 |
F3 S1 APARTMENT | 3818.75 | 4472.25 | 673.00 |
F3 S2 APARTMENT | 3826.50 | 4454.50 | 672.25 |
F4 SW APARTMENT | 3967.00 | 4622.25 | 778.00 |
F4 NW APARTMENT | 3819.75 | 5429.00 | 1102.25 |
F4 SE APARTMENT | 3974.25 | 4602.00 | 743.75 |
F4 NE APARTMENT | 3750.25 | 5461.50 | 1065.75 |
F4 N1 APARTMENT | 3432.25 | 5567.00 | 823.25 |
F4 N2 APARTMENT | 3422.00 | 5579.00 | 823.75 |
F4 S1 APARTMENT | 3864.25 | 4404.50 | 678.50 |
F4 S2 APARTMENT | 3866.00 | 4401.25 | 679.50 |
M SW APARTMENT | 3960.50 | 4653.50 | 782.25 |
M NW APARTMENT | 3813.25 | 5439.00 | 1100.75 |
M SE APARTMENT | 3961.50 | 4639.50 | 749.50 |
M NE APARTMENT | 3743.75 | 5476.25 | 1064.00 |
M N1 APARTMENT | 3441.50 | 5551.75 | 813.25 |
M N2 APARTMENT | 3431.00 | 5557.50 | 812.75 |
M S1 APARTMENT | 3870.50 | 4420.50 | 679.00 |
M S2 APARTMENT | 3870.00 | 4420.25 | 680.25 |
F6 SW APARTMENT | 3889.00 | 4812.50 | 825.50 |
F6 NW APARTMENT | 3779.75 | 5583.25 | 1176.25 |
F6 SE APARTMENT | 3883.75 | 4821.25 | 802.50 |
F6 NE APARTMENT | 3724.50 | 5625.25 | 1142.00 |
F6 N1 APARTMENT | 3381.25 | 5690.00 | 856.50 |
F6 N2 APARTMENT | 3377.75 | 5698.75 | 856.75 |
F6 S1 APARTMENT | 3775.50 | 4621.25 | 707.00 |
F6 S2 APARTMENT | 3778.00 | 4622.25 | 707.25 |
F7 SW APARTMENT | 3825.50 | 4927.00 | 852.50 |
F7 NW APARTMENT | 3755.75 | 5685.25 | 1221.25 |
F7 SE APARTMENT | 3824.50 | 4951.00 | 831.00 |
F7 NE APARTMENT | 3715.00 | 5733.25 | 1191.25 |
F7 N1 APARTMENT | 3345.00 | 5796.25 | 889.75 |
F7 N2 APARTMENT | 3339.25 | 5808.50 | 888.25 |
F7 S1 APARTMENT | 3717.75 | 4759.25 | 728.50 |
F7 S2 APARTMENT | 3714.75 | 4759.75 | 728.75 |
F8 SW APARTMENT | 3781.75 | 5028.50 | 879.50 |
F8 NW APARTMENT | 3750.00 | 5762.50 | 1262.25 |
F8 SE APARTMENT | 3773.75 | 5071.00 | 852.00 |
F8 NE APARTMENT | 3712.75 | 5818.00 | 1231.25 |
F8 N1 APARTMENT | 3317.75 | 5877.50 | 912.25 |
F8 N2 APARTMENT | 3316.00 | 5887.75 | 912.75 |
F8 S1 APARTMENT | 3659.00 | 4882.50 | 742.00 |
F8 S2 APARTMENT | 3658.25 | 4884.00 | 742.25 |
F9 SW APARTMENT | 3760.25 | 5146.50 | 920.75 |
F9 NW APARTMENT | 3831.50 | 5822.75 | 1368.75 |
F9 SE APARTMENT | 3750.50 | 5185.25 | 900.50 |
F9 NE APARTMENT | 3785.50 | 5868.00 | 1333.25 |
F9 N1 APARTMENT | 3366.50 | 5946.00 | 991.75 |
F9 N2 APARTMENT | 3361.50 | 5955.50 | 989.00 |
F9 S1 APARTMENT | 3607.75 | 5026.75 | 775.75 |
F9 S2 APARTMENT | 3604.25 | 5028.00 | 775.75 |
T SW APARTMENT | 4336.25 | 5460.25 | 1668.25 |
T NW APARTMENT | 4491.00 | 6037.50 | 2182.25 |
T SE APARTMENT | 4350.00 | 5446.50 | 1653.00 |
T NE APARTMENT | 4445.50 | 6075.25 | 2152.25 |
T N1 APARTMENT | 3886.75 | 6144.75 | 1689.00 |
T N2 APARTMENT | 3884.25 | 6151.25 | 1686.25 |
T S1 APARTMENT | 3919.75 | 5322.75 | 1246.25 |
T S2 APARTMENT | 3924.00 | 5325.50 | 1252.25 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 5647.00 | 6924.25 | 2612.75 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 3.25 | 4.75 | 3.25 | 4.75 |
G NW APARTMENT | 1.00 | 5.75 | 1.00 | 5.75 |
OFFICE | 3.00 | 0.00 | 0.25 | 0.00 |
G NE APARTMENT | 2.25 | 20.25 | 2.25 | 20.25 |
G N1 APARTMENT | 5.00 | 14.75 | 5.00 | 14.75 |
G N2 APARTMENT | 4.50 | 16.75 | 4.50 | 16.75 |
G S1 APARTMENT | 4.00 | 20.50 | 4.00 | 20.50 |
G S2 APARTMENT | 2.25 | 14.50 | 2.25 | 14.50 |
F2 SW APARTMENT | 0.75 | 2.50 | 0.75 | 2.50 |
F2 NW APARTMENT | 0.50 | 4.50 | 0.50 | 4.50 |
F2 SE APARTMENT | 1.25 | 0.00 | 1.25 | 0.00 |
F2 NE APARTMENT | 2.25 | 18.00 | 2.25 | 18.00 |
F2 N1 APARTMENT | 4.00 | 18.00 | 4.00 | 18.00 |
F2 N2 APARTMENT | 3.75 | 20.50 | 3.75 | 20.50 |
F2 S1 APARTMENT | 2.25 | 12.00 | 2.25 | 12.00 |
F2 S2 APARTMENT | 2.75 | 9.25 | 2.75 | 9.25 |
F3 SW APARTMENT | 1.75 | 2.75 | 1.75 | 2.75 |
F3 NW APARTMENT | 0.75 | 4.00 | 0.75 | 4.00 |
F3 SE APARTMENT | 1.00 | 7.50 | 1.00 | 7.50 |
F3 NE APARTMENT | 1.00 | 20.75 | 1.00 | 20.75 |
F3 N1 APARTMENT | 3.50 | 25.50 | 3.50 | 25.50 |
F3 N2 APARTMENT | 3.50 | 28.75 | 3.50 | 28.75 |
F3 S1 APARTMENT | 3.75 | 19.50 | 3.75 | 19.50 |
F3 S2 APARTMENT | 2.00 | 18.25 | 2.00 | 18.25 |
F4 SW APARTMENT | 2.25 | 2.75 | 2.25 | 2.75 |
F4 NW APARTMENT | 0.25 | 4.25 | 0.25 | 4.25 |
F4 SE APARTMENT | 3.00 | 8.25 | 3.00 | 8.25 |
F4 NE APARTMENT | 1.50 | 21.25 | 1.50 | 21.25 |
F4 N1 APARTMENT | 3.75 | 28.00 | 3.75 | 28.00 |
F4 N2 APARTMENT | 2.25 | 30.00 | 2.25 | 30.00 |
F4 S1 APARTMENT | 2.25 | 20.75 | 2.25 | 20.75 |
F4 S2 APARTMENT | 1.25 | 19.25 | 1.25 | 19.25 |
M SW APARTMENT | 1.25 | 2.50 | 1.25 | 2.50 |
M NW APARTMENT | 1.00 | 4.25 | 1.00 | 4.25 |
M SE APARTMENT | 1.50 | 7.75 | 1.50 | 7.75 |
M NE APARTMENT | 1.00 | 21.50 | 1.00 | 21.50 |
M N1 APARTMENT | 3.75 | 29.50 | 3.75 | 29.50 |
M N2 APARTMENT | 3.75 | 31.25 | 3.75 | 31.25 |
M S1 APARTMENT | 2.00 | 21.25 | 2.00 | 21.25 |
M S2 APARTMENT | 3.25 | 19.00 | 3.25 | 19.00 |
F6 SW APARTMENT | 0.25 | 3.00 | 0.25 | 3.00 |
F6 NW APARTMENT | 0.25 | 4.25 | 0.25 | 4.25 |
F6 SE APARTMENT | 1.25 | 8.50 | 1.25 | 8.50 |
F6 NE APARTMENT | 0.75 | 22.25 | 0.75 | 22.25 |
F6 N1 APARTMENT | 4.75 | 30.00 | 4.75 | 30.00 |
F6 N2 APARTMENT | 3.50 | 32.00 | 3.50 | 32.00 |
F6 S1 APARTMENT | 2.50 | 21.25 | 2.50 | 21.25 |
F6 S2 APARTMENT | 3.50 | 19.75 | 3.50 | 19.75 |
F7 SW APARTMENT | 1.00 | 3.00 | 1.00 | 3.00 |
F7 NW APARTMENT | 0.00 | 4.25 | 0.00 | 4.25 |
F7 SE APARTMENT | 0.75 | 9.00 | 0.75 | 9.00 |
F7 NE APARTMENT | 0.25 | 21.50 | 0.25 | 21.50 |
F7 N1 APARTMENT | 2.75 | 30.50 | 2.75 | 30.50 |
F7 N2 APARTMENT | 2.75 | 32.00 | 2.75 | 32.00 |
F7 S1 APARTMENT | 1.00 | 21.50 | 1.00 | 21.50 |
F7 S2 APARTMENT | 1.50 | 19.75 | 1.50 | 19.75 |
F8 SW APARTMENT | 0.25 | 3.00 | 0.25 | 3.00 |
F8 NW APARTMENT | 0.25 | 4.25 | 0.25 | 4.25 |
F8 SE APARTMENT | 1.00 | 8.25 | 1.00 | 8.25 |
F8 NE APARTMENT | 0.50 | 21.75 | 0.50 | 21.75 |
F8 N1 APARTMENT | 4.00 | 30.50 | 4.00 | 30.50 |
F8 N2 APARTMENT | 3.25 | 32.25 | 3.25 | 32.25 |
F8 S1 APARTMENT | 1.25 | 21.25 | 1.25 | 21.25 |
F8 S2 APARTMENT | 2.25 | 18.75 | 2.25 | 18.75 |
F9 SW APARTMENT | 0.75 | 2.75 | 0.75 | 2.75 |
F9 NW APARTMENT | 0.00 | 4.00 | 0.00 | 4.00 |
F9 SE APARTMENT | 1.50 | 7.25 | 1.50 | 7.25 |
F9 NE APARTMENT | 0.50 | 20.75 | 0.50 | 20.75 |
F9 N1 APARTMENT | 3.25 | 27.25 | 3.25 | 27.25 |
F9 N2 APARTMENT | 3.25 | 29.25 | 3.25 | 29.25 |
F9 S1 APARTMENT | 2.75 | 19.00 | 2.75 | 19.00 |
F9 S2 APARTMENT | 2.75 | 16.75 | 2.75 | 16.75 |
T SW APARTMENT | 0.00 | 1.25 | 0.00 | 1.25 |
T NW APARTMENT | 0.00 | 3.00 | 0.00 | 3.00 |
T SE APARTMENT | 0.00 | 4.50 | 0.00 | 4.50 |
T NE APARTMENT | 0.00 | 14.00 | 0.00 | 14.00 |
T N1 APARTMENT | 0.75 | 11.00 | 0.75 | 11.00 |
T N2 APARTMENT | 0.25 | 11.50 | 0.25 | 11.50 |
T S1 APARTMENT | 0.75 | 3.25 | 0.75 | 3.25 |
T S2 APARTMENT | 1.00 | 3.25 | 1.00 | 3.25 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 116.25 | 71.00 | 114.00 | 71.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.176 | 0.000 | 0.311 |
G NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.176 | 0.000 | 0.301 |
OFFICE | 0.94 | 1.00 | 268.96 | 0.519 | 0.208 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.176 | 0.000 | 0.301 |
G N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.106 | 0.000 | 0.295 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.106 | 0.000 | 0.295 |
G S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.106 | 0.000 | 0.308 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.106 | 0.000 | 0.309 |
F2 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.253 | 0.000 | 0.363 |
F2 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.253 | 0.000 | 0.352 |
F2 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.253 | 0.000 | 0.365 |
F2 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.253 | 0.000 | 0.352 |
F2 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.152 | 0.000 | 0.348 |
F2 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.152 | 0.000 | 0.348 |
F2 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.153 | 0.000 | 0.362 |
F2 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.153 | 0.000 | 0.362 |
F3 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.300 | 0.000 | 0.398 |
F3 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.299 | 0.000 | 0.386 |
F3 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.300 | 0.000 | 0.399 |
F3 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.299 | 0.000 | 0.386 |
F3 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.180 | 0.000 | 0.383 |
F3 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.180 | 0.000 | 0.383 |
F3 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.181 | 0.000 | 0.397 |
F3 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.181 | 0.000 | 0.397 |
F4 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.335 | 0.000 | 0.414 |
F4 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.334 | 0.000 | 0.402 |
F4 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.335 | 0.000 | 0.414 |
F4 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.334 | 0.000 | 0.402 |
F4 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.202 | 0.000 | 0.399 |
F4 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.202 | 0.000 | 0.399 |
F4 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.202 | 0.000 | 0.413 |
F4 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.202 | 0.000 | 0.413 |
M SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.364 | 0.000 | 0.434 |
M NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.363 | 0.000 | 0.421 |
M SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.364 | 0.000 | 0.434 |
M NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.363 | 0.000 | 0.421 |
M N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.219 | 0.000 | 0.418 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.219 | 0.000 | 0.418 |
M S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.219 | 0.000 | 0.433 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.219 | 0.000 | 0.433 |
F6 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.389 | 0.000 | 0.450 |
F6 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.388 | 0.000 | 0.437 |
F6 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.389 | 0.000 | 0.451 |
F6 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.388 | 0.000 | 0.437 |
F6 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.234 | 0.000 | 0.435 |
F6 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.234 | 0.000 | 0.435 |
F6 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.234 | 0.000 | 0.449 |
F6 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.234 | 0.000 | 0.449 |
F7 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.411 | 0.000 | 0.465 |
F7 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.410 | 0.000 | 0.452 |
F7 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.411 | 0.000 | 0.465 |
F7 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.410 | 0.000 | 0.452 |
F7 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.247 | 0.000 | 0.449 |
F7 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.247 | 0.000 | 0.449 |
F7 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.248 | 0.000 | 0.464 |
F7 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.248 | 0.000 | 0.464 |
F8 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.430 | 0.000 | 0.480 |
F8 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.430 | 0.000 | 0.467 |
F8 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.430 | 0.000 | 0.481 |
F8 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.430 | 0.000 | 0.466 |
F8 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.259 | 0.000 | 0.464 |
F8 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.259 | 0.000 | 0.464 |
F8 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.260 | 0.000 | 0.479 |
F8 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.260 | 0.000 | 0.479 |
F9 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.449 | 0.000 | 0.494 |
F9 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.448 | 0.000 | 0.480 |
F9 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.449 | 0.000 | 0.494 |
F9 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.448 | 0.000 | 0.479 |
F9 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.270 | 0.000 | 0.477 |
F9 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.270 | 0.000 | 0.477 |
F9 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.271 | 0.000 | 0.493 |
F9 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.271 | 0.000 | 0.493 |
T SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.465 | 0.000 | 0.504 |
T NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.465 | 0.000 | 0.490 |
T SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.465 | 0.000 | 0.505 |
T NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.465 | 0.000 | 0.490 |
T N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.280 | 0.000 | 0.488 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.280 | 0.000 | 0.488 |
T S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.281 | 0.000 | 0.503 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.281 | 0.000 | 0.503 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.96 | 0.499 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Surfaces by ClassTotal | Outdoors | |
Wall | 420 | 140 |
Floor | 90 | 9 |
Roof | 90 | 9 |
Internal Mass | 80 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 140 | 140 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 80 |
Conditioned Zones | 80 |
Unconditioned Zones | 10 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 4156 |
Defaulted Fields | 814 |
Fields with Defaults | 11184 |
Autosized Fields | 1293 |
Autosizable Fields | 1630 |
Autocalculated Fields | 907 |
Autocalculatable Fields | 1710 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 3059.89 | 55025.88 | 14-MAY-05:00 | 185618.30 | 03-SEP-18:45 |
Electricity:Building | 1433.88 | 25760.85 | 01-JAN-03:15 | 70162.48 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity | 296.56 | 6715.87 | 01-JAN-00:15 | 14401.37 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 242.55 | 5824.91 | 01-JAN-00:15 | 11484.27 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 39.38 | 663.42 | 01-JAN-00:15 | 2934.49 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 29.88 | 469.18 | 01-JAN-00:15 | 2345.88 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F2 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F2 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F3 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F3 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F4 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F4 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:M SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M CORRIDOR | 32.88 | 1042.61 | 01-JAN-00:15 | 1042.61 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 32.88 | 1042.61 | 01-JAN-00:15 | 1042.61 | 01-JAN-00:15 |
Electricity:Zone:F6 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F6 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F7 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F7 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F8 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F8 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F9 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F9 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:T SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T CORRIDOR | 179.47 | 1701.70 | 01-JAN-00:15 | 10868.20 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 54.01 | 890.97 | 01-JAN-00:15 | 2917.11 | 01-JAN-19:15 |
InteriorEquipment:Electricity | 1137.32 | 19044.98 | 01-JAN-03:15 | 57142.09 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 1137.32 | 19044.98 | 01-JAN-03:15 | 57142.09 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 9.50 | 194.24 | 01-JAN-00:15 | 588.62 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T CORRIDOR | 163.03 | 1180.40 | 01-JAN-00:15 | 10346.90 | 01-JAN-07:15 |
Fans:Electricity | 640.55 | 20311.59 | 12-JAN-05:15 | 20311.59 | 01-JAN-00:15 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Electricity:HVAC | 1367.29 | 20972.83 | 28-MAR-02:15 | 108729.40 | 20-JUL-13:30 |
ElectricityProduced:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityProduced:HVAC | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricityProduced | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 3059.89 | 55025.88 | 14-MAY-05:00 | 185618.30 | 03-SEP-18:45 |
ElectricityPurchased:Plant | 3059.89 | 55025.88 | 14-MAY-05:00 | 185618.30 | 03-SEP-18:45 |
Cogeneration:ElectricityPurchased | 3059.89 | 55025.88 | 14-MAY-05:00 | 185618.30 | 03-SEP-18:45 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 3059.89 | 55025.88 | 14-MAY-05:00 | 185618.30 | 03-SEP-18:45 |
ElectricityNet:Plant | 3059.89 | 55025.88 | 14-MAY-05:00 | 185618.30 | 03-SEP-18:45 |
Cogeneration:ElectricityNet | 3059.89 | 55025.88 | 14-MAY-05:00 | 185618.30 | 03-SEP-18:45 |
ExteriorLights:Electricity | 162.88 | 0.00 | 01-JAN-07:45 | 10364.00 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 162.88 | 0.00 | 01-JAN-07:45 | 10364.00 | 01-JAN-00:15 |
General:Fans:Electricity | 640.55 | 20311.59 | 12-JAN-05:15 | 20311.59 | 01-JAN-00:15 |
Cooling:Electricity | 491.20 | 0.00 | 01-JAN-00:15 | 87338.51 | 20-JUL-13:30 |
Heating:Electricity | 199.37 | 0.00 | 01-FEB-14:45 | 68931.86 | 25-DEC-06:00 |
Electricity:Plant | 95.84 | 36.93 | 01-FEB-22:15 | 5909.01 | 08-JUL-17:45 |
HeatRejection:Electricity | 23.01 | 0.00 | 01-JAN-00:15 | 3534.15 | 08-JUL-17:45 |
Boiler Parasitic:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Pumps:Electricity | 72.83 | 36.93 | 01-FEB-22:15 | 2374.85 | 01-JAN-00:15 |
WIRED_LTG_ELECTRICITY | 0.44 | 0.00 | 01-JAN-00:15 | 21.60 | 01-JAN-19:30 |
WIRED_INT_EQUIP | 979.40 | 1018.50 | 01-JAN-00:15 | 10185.00 | 01-JAN-07:15 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 1812.97 | 2357.00 | 26-JAN-23:30 | 365692.46 | 25-DEC-07:15 |
Gas:Plant | 1812.97 | 2357.00 | 26-JAN-23:30 | 365692.46 | 25-DEC-07:15 |
WaterSystems:Gas | 1105.82 | 2357.00 | 01-JAN-00:15 | 81197.72 | 11-FEB-08:00 |
Water Heater:WaterSystems:Gas | 1105.82 | 2357.00 | 01-JAN-00:15 | 81197.72 | 11-FEB-08:00 |
Heating:Gas | 707.16 | 0.00 | 26-JAN-17:00 | 294606.75 | 25-DEC-06:00 |
Boiler:Heating:Gas | 707.16 | 0.00 | 26-JAN-17:00 | 294606.75 | 25-DEC-06:00 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
PlantLoopCoolingDemand:Facility | 2144.69 | 0.00 | 01-JAN-00:15 | 418269.79 | 14-SEP-10:30 |
PlantLoopCoolingDemand:HVAC | 2144.69 | 0.00 | 01-JAN-00:15 | 418269.79 | 14-SEP-10:30 |
CoolingCoils:PlantLoopCoolingDemand | 2144.69 | 0.00 | 01-JAN-00:15 | 418269.79 | 14-SEP-10:30 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 6147.67 | 0.00 | 01-JAN-02:15 | 0.00 | 09-JUL-17:15 |
Water:Plant | 6147.67 | 0.00 | 01-JAN-02:15 | 0.00 | 09-JUL-17:15 |
WaterSystems:Water | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:Water | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
MainsWater:Facility | 6147.67 | 0.00 | 01-JAN-02:15 | 0.00 | 09-JUL-17:15 |
MainsWater:Plant | 6147.67 | 0.00 | 01-JAN-02:15 | 0.00 | 09-JUL-17:15 |
WaterSystems:MainsWater | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:MainsWater | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
sub cat:WaterSystems:Water | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
sub cat:WaterSystems:MainsWater | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
HeatRejection:Water | 1369.16 | 0.00 | 01-JAN-00:15 | 0.00 | 20-JUL-14:45 |
HeatRejection:MainsWater | 1369.16 | 0.00 | 01-JAN-00:15 | 0.00 | 20-JUL-14:45 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 1430.11 | 432.62 | 20-AUG-01:15 | 275408.69 | 25-DEC-06:15 |
PlantLoopHeatingDemand:Plant | 859.80 | 432.62 | 20-AUG-01:15 | 59803.77 | 07-FEB-07:45 |
WaterSystems:PlantLoopHeatingDemand | 859.80 | 432.62 | 20-AUG-01:15 | 59803.77 | 07-FEB-07:45 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 5385.58 | 5550.08 | 28-NOV-02:15 | 785949.72 | 25-DEC-06:15 |
EnergyTransfer:Building | 1563.99 | 3524.65 | 05-AUG-05:45 | 227775.41 | 25-DEC-05:00 |
EnergyTransfer:Zone:G SW APARTMENT | 15.47 | 0.04 | 30-SEP-06:45 | 2559.42 | 17-AUG-16:30 |
Heating:EnergyTransfer | 493.60 | 0.00 | 17-FEB-14:00 | 227775.41 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 5.34 | 0.00 | 01-JAN-10:30 | 2309.10 | 25-DEC-05:00 |
Cooling:EnergyTransfer | 1070.39 | 0.00 | 01-JAN-03:00 | 191175.64 | 29-JUN-16:30 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 10.14 | 0.00 | 01-JAN-00:15 | 2559.42 | 17-AUG-16:30 |
EnergyTransfer:Zone:G NW APARTMENT | 16.35 | 0.08 | 11-MAR-15:30 | 2547.33 | 25-DEC-08:30 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 8.54 | 0.00 | 26-JAN-18:15 | 2547.33 | 25-DEC-08:30 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 7.81 | 0.00 | 01-JAN-00:15 | 2391.83 | 10-JUL-17:15 |
EnergyTransfer:Zone:OFFICE | 23.49 | 0.05 | 22-MAY-01:45 | 3800.41 | 29-AUG-13:15 |
Heating:EnergyTransfer:Zone:OFFICE | 3.96 | 0.00 | 01-JAN-10:00 | 2351.68 | 25-DEC-07:15 |
Cooling:EnergyTransfer:Zone:OFFICE | 19.53 | 0.00 | 01-JAN-00:15 | 3800.41 | 29-AUG-13:15 |
EnergyTransfer:Zone:G NE APARTMENT | 16.24 | 0.04 | 08-OCT-04:15 | 2329.95 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 8.26 | 0.00 | 26-JAN-19:00 | 2329.95 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 7.98 | 0.00 | 01-JAN-00:15 | 1824.74 | 11-JUL-07:45 |
EnergyTransfer:Zone:G N1 APARTMENT | 10.90 | 0.00 | 22-AUG-09:00 | 1586.39 | 25-DEC-08:30 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 4.68 | 0.00 | 26-JAN-16:30 | 1586.39 | 25-DEC-08:30 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 6.22 | 0.00 | 01-JAN-00:15 | 1262.76 | 10-JUL-17:45 |
EnergyTransfer:Zone:G N2 APARTMENT | 10.90 | 0.01 | 29-MAY-05:45 | 1582.25 | 25-DEC-08:30 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 4.67 | 0.00 | 26-JAN-16:30 | 1582.25 | 25-DEC-08:30 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 6.23 | 0.00 | 01-JAN-00:15 | 1247.69 | 10-JUL-17:45 |
EnergyTransfer:Zone:G S1 APARTMENT | 11.12 | 0.03 | 27-MAY-09:30 | 1730.48 | 07-SEP-14:00 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 1.93 | 0.00 | 01-JAN-09:15 | 1312.78 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 9.20 | 0.00 | 01-JAN-00:15 | 1730.48 | 07-SEP-14:00 |
EnergyTransfer:Zone:G S2 APARTMENT | 11.28 | 0.01 | 13-JAN-23:00 | 1798.71 | 07-SEP-14:00 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 1.82 | 0.00 | 01-JAN-09:00 | 1306.79 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 9.46 | 0.00 | 01-JAN-00:15 | 1798.71 | 07-SEP-14:00 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F2 SW APARTMENT | 20.60 | 0.07 | 14-MAR-12:15 | 3214.71 | 17-AUG-16:30 |
Heating:EnergyTransfer:Zone:F2 SW APARTMENT | 4.30 | 0.00 | 01-JAN-10:15 | 2791.47 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT | 16.30 | 0.00 | 01-JAN-00:15 | 3214.71 | 17-AUG-16:30 |
EnergyTransfer:Zone:F2 NW APARTMENT | 20.26 | 0.03 | 06-NOV-00:15 | 3030.15 | 29-JUN-16:30 |
Heating:EnergyTransfer:Zone:F2 NW APARTMENT | 8.03 | 0.00 | 16-JAN-15:15 | 2872.27 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT | 12.23 | 0.00 | 01-JAN-00:15 | 3030.15 | 29-JUN-16:30 |
EnergyTransfer:Zone:F2 SE APARTMENT | 21.63 | 0.03 | 13-JAN-17:00 | 3075.15 | 29-AUG-13:45 |
Heating:EnergyTransfer:Zone:F2 SE APARTMENT | 3.67 | 0.00 | 01-JAN-09:15 | 2775.96 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT | 17.97 | 0.00 | 01-JAN-00:15 | 3075.15 | 29-AUG-13:45 |
EnergyTransfer:Zone:F2 NE APARTMENT | 20.31 | 0.00 | 19-APR-15:00 | 2872.95 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:F2 NE APARTMENT | 7.79 | 0.00 | 16-JAN-18:15 | 2872.95 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT | 12.52 | 0.00 | 01-JAN-00:15 | 2391.48 | 11-JUL-07:45 |
EnergyTransfer:Zone:F2 N1 APARTMENT | 13.42 | 0.01 | 09-DEC-02:45 | 1714.01 | 23-JUN-18:15 |
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT | 3.41 | 0.00 | 02-JAN-20:45 | 1606.64 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT | 10.01 | 0.00 | 01-JAN-00:15 | 1714.01 | 23-JUN-18:15 |
EnergyTransfer:Zone:F2 N2 APARTMENT | 13.42 | 0.04 | 27-MAY-20:30 | 1700.02 | 02-JUN-17:30 |
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT | 3.41 | 0.00 | 02-JAN-20:45 | 1607.44 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT | 10.01 | 0.00 | 01-JAN-00:15 | 1700.02 | 02-JUN-17:30 |
EnergyTransfer:Zone:F2 S1 APARTMENT | 15.99 | 0.01 | 16-OCT-19:00 | 2268.64 | 07-SEP-14:00 |
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT | 1.10 | 0.00 | 01-JAN-00:15 | 1511.05 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT | 14.89 | 0.00 | 01-JAN-02:30 | 2268.64 | 07-SEP-14:00 |
EnergyTransfer:Zone:F2 S2 APARTMENT | 16.10 | 0.03 | 25-APR-19:15 | 2290.05 | 07-SEP-14:00 |
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT | 1.07 | 0.00 | 01-JAN-00:15 | 1510.87 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT | 15.03 | 0.00 | 01-JAN-02:30 | 2290.05 | 07-SEP-14:00 |
EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F3 SW APARTMENT | 21.63 | 0.00 | 10-DEC-01:30 | 3245.60 | 29-JUN-16:30 |
Heating:EnergyTransfer:Zone:F3 SW APARTMENT | 4.53 | 0.00 | 01-JAN-10:30 | 3052.15 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT | 17.11 | 0.00 | 01-JAN-00:15 | 3245.60 | 29-JUN-16:30 |
EnergyTransfer:Zone:F3 NW APARTMENT | 21.31 | 0.03 | 31-OCT-24:00 | 3147.36 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:F3 NW APARTMENT | 8.40 | 0.00 | 15-JAN-18:00 | 3147.36 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT | 12.91 | 0.00 | 01-JAN-00:15 | 3112.15 | 29-JUN-16:30 |
EnergyTransfer:Zone:F3 SE APARTMENT | 21.86 | 0.00 | 09-APR-09:30 | 3055.49 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:F3 SE APARTMENT | 4.28 | 0.00 | 01-JAN-09:45 | 3055.49 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT | 17.59 | 0.00 | 01-JAN-00:15 | 2938.06 | 07-SEP-11:00 |
EnergyTransfer:Zone:F3 NE APARTMENT | 21.34 | 0.01 | 31-AUG-04:45 | 3147.17 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:F3 NE APARTMENT | 8.16 | 0.00 | 15-JAN-18:00 | 3147.17 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT | 13.18 | 0.00 | 01-JAN-00:15 | 2480.64 | 02-AUG-09:00 |
EnergyTransfer:Zone:F3 N1 APARTMENT | 14.22 | 0.01 | 02-MAY-14:15 | 1807.13 | 23-JUN-18:15 |
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT | 3.42 | 0.00 | 01-JAN-19:00 | 1775.60 | 23-FEB-11:45 |
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT | 10.80 | 0.00 | 01-JAN-00:15 | 1807.13 | 23-JUN-18:15 |
EnergyTransfer:Zone:F3 N2 APARTMENT | 14.22 | 0.03 | 24-SEP-18:45 | 1790.73 | 23-JUN-18:15 |
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT | 3.41 | 0.00 | 01-JAN-19:00 | 1754.20 | 23-FEB-11:45 |
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT | 10.80 | 0.00 | 01-JAN-00:15 | 1790.73 | 23-JUN-18:15 |
EnergyTransfer:Zone:F3 S1 APARTMENT | 17.16 | 0.03 | 22-APR-21:00 | 2350.92 | 17-OCT-13:00 |
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT | 1.09 | 0.00 | 01-JAN-00:15 | 1624.52 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT | 16.07 | 0.00 | 01-JAN-03:00 | 2350.92 | 17-OCT-13:00 |
EnergyTransfer:Zone:F3 S2 APARTMENT | 17.20 | 0.01 | 08-SEP-07:00 | 2358.04 | 17-OCT-13:00 |
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT | 1.09 | 0.00 | 01-JAN-00:15 | 1625.96 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT | 16.11 | 0.00 | 01-JAN-02:45 | 2358.04 | 17-OCT-13:00 |
EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F4 SW APARTMENT | 22.14 | 0.02 | 24-DEC-13:15 | 3291.41 | 29-JUN-16:30 |
Heating:EnergyTransfer:Zone:F4 SW APARTMENT | 5.04 | 0.00 | 01-JAN-10:30 | 3289.99 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT | 17.10 | 0.00 | 01-JAN-00:15 | 3291.41 | 29-JUN-16:30 |
EnergyTransfer:Zone:F4 NW APARTMENT | 22.06 | 0.01 | 14-NOV-17:00 | 3391.09 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:F4 NW APARTMENT | 9.06 | 0.00 | 15-JAN-18:00 | 3391.09 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT | 13.00 | 0.00 | 01-JAN-00:15 | 3161.19 | 29-JUN-16:30 |
EnergyTransfer:Zone:F4 SE APARTMENT | 22.25 | 0.03 | 20-MAR-03:00 | 3296.07 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:F4 SE APARTMENT | 4.86 | 0.00 | 01-JAN-10:00 | 3296.07 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT | 17.39 | 0.00 | 01-JAN-00:15 | 2952.74 | 07-SEP-11:00 |
EnergyTransfer:Zone:F4 NE APARTMENT | 22.07 | 0.04 | 27-NOV-23:00 | 3390.16 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:F4 NE APARTMENT | 8.81 | 0.00 | 15-JAN-18:00 | 3390.16 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT | 13.26 | 0.00 | 01-JAN-00:15 | 2529.71 | 02-AUG-09:00 |
EnergyTransfer:Zone:F4 N1 APARTMENT | 14.64 | 0.01 | 24-SEP-19:00 | 1972.84 | 23-FEB-11:45 |
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT | 3.69 | 0.00 | 02-JAN-08:00 | 1972.84 | 23-FEB-11:45 |
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT | 10.95 | 0.00 | 01-JAN-00:15 | 1852.32 | 23-JUN-18:15 |
EnergyTransfer:Zone:F4 N2 APARTMENT | 14.64 | 0.01 | 13-APR-16:00 | 1951.33 | 23-FEB-11:45 |
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT | 3.68 | 0.00 | 02-JAN-08:00 | 1951.33 | 23-FEB-11:45 |
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT | 10.95 | 0.00 | 01-JAN-00:15 | 1835.99 | 23-JUN-18:15 |
EnergyTransfer:Zone:F4 S1 APARTMENT | 17.44 | 0.02 | 25-MAY-19:45 | 2402.55 | 17-OCT-13:00 |
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT | 1.24 | 0.00 | 01-JAN-00:15 | 1753.78 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT | 16.20 | 0.00 | 01-JAN-02:30 | 2402.55 | 17-OCT-13:00 |
EnergyTransfer:Zone:F4 S2 APARTMENT | 17.45 | 0.01 | 02-JUN-06:30 | 2408.17 | 17-OCT-13:00 |
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT | 1.24 | 0.00 | 01-JAN-00:15 | 1755.60 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT | 16.21 | 0.00 | 01-JAN-02:30 | 2408.17 | 17-OCT-13:00 |
EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M SW APARTMENT | 22.65 | 0.02 | 14-APR-00:15 | 3480.65 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 5.49 | 0.00 | 01-JAN-10:45 | 3480.65 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 17.16 | 0.00 | 01-JAN-00:15 | 3348.60 | 29-JUN-16:30 |
EnergyTransfer:Zone:M NW APARTMENT | 22.77 | 0.02 | 27-SEP-04:00 | 3582.33 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 9.59 | 0.00 | 15-JAN-18:00 | 3582.33 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 13.19 | 0.00 | 01-JAN-00:15 | 3221.32 | 29-JUN-16:30 |
EnergyTransfer:Zone:M SE APARTMENT | 22.72 | 0.03 | 28-MAR-03:00 | 3486.52 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 5.31 | 0.00 | 01-JAN-10:15 | 3486.52 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 17.41 | 0.00 | 01-JAN-00:15 | 2999.61 | 07-SEP-11:00 |
EnergyTransfer:Zone:M NE APARTMENT | 22.76 | 0.09 | 16-NOV-20:30 | 3581.16 | 25-DEC-04:00 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 9.32 | 0.00 | 15-JAN-18:00 | 3581.16 | 25-DEC-04:00 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 13.45 | 0.00 | 01-JAN-00:15 | 2589.81 | 02-AUG-09:00 |
EnergyTransfer:Zone:M N1 APARTMENT | 15.09 | 0.08 | 05-JUN-10:30 | 2134.83 | 23-FEB-11:45 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 3.91 | 0.00 | 02-JAN-08:00 | 2134.83 | 23-FEB-11:45 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 11.18 | 0.00 | 01-JAN-00:15 | 1905.46 | 23-JUN-18:15 |
EnergyTransfer:Zone:M N2 APARTMENT | 15.09 | 0.04 | 19-NOV-23:15 | 2113.01 | 23-FEB-11:45 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 3.90 | 0.00 | 02-JAN-08:00 | 2113.01 | 23-FEB-11:45 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 11.18 | 0.00 | 01-JAN-00:15 | 1889.17 | 23-JUN-18:15 |
EnergyTransfer:Zone:M S1 APARTMENT | 17.70 | 0.07 | 20-SEP-17:45 | 2443.73 | 17-OCT-13:00 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 1.38 | 0.00 | 01-JAN-00:15 | 1859.29 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 16.32 | 0.00 | 01-JAN-02:15 | 2443.73 | 17-OCT-13:00 |
EnergyTransfer:Zone:M S2 APARTMENT | 17.71 | 0.01 | 08-OCT-18:45 | 2449.16 | 17-OCT-13:00 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 1.38 | 0.00 | 01-JAN-00:15 | 1861.16 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 16.33 | 0.00 | 01-JAN-02:15 | 2449.16 | 17-OCT-13:00 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F6 SW APARTMENT | 22.66 | 0.05 | 21-MAY-02:15 | 3700.45 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:F6 SW APARTMENT | 6.27 | 0.00 | 01-JAN-11:00 | 3700.45 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT | 16.40 | 0.00 | 01-JAN-00:15 | 3342.23 | 29-JUN-16:30 |
EnergyTransfer:Zone:F6 NW APARTMENT | 23.28 | 0.02 | 08-MAR-19:30 | 3814.91 | 13-FEB-11:00 |
Heating:EnergyTransfer:Zone:F6 NW APARTMENT | 10.60 | 0.00 | 15-JAN-18:00 | 3814.91 | 13-FEB-11:00 |
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT | 12.68 | 0.00 | 01-JAN-00:15 | 3215.86 | 29-JUN-16:30 |
EnergyTransfer:Zone:F6 SE APARTMENT | 22.70 | 0.02 | 13-DEC-13:00 | 3705.30 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:F6 SE APARTMENT | 6.07 | 0.00 | 01-JAN-10:30 | 3705.30 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT | 16.62 | 0.00 | 01-JAN-00:15 | 2985.09 | 07-SEP-11:00 |
EnergyTransfer:Zone:F6 NE APARTMENT | 23.24 | 0.12 | 07-DEC-04:15 | 3802.97 | 25-DEC-04:00 |
Heating:EnergyTransfer:Zone:F6 NE APARTMENT | 10.31 | 0.00 | 15-JAN-18:00 | 3802.97 | 25-DEC-04:00 |
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT | 12.92 | 0.00 | 01-JAN-00:15 | 2584.55 | 02-AUG-09:00 |
EnergyTransfer:Zone:F6 N1 APARTMENT | 15.13 | 0.01 | 09-DEC-05:30 | 2352.84 | 23-FEB-11:45 |
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT | 4.50 | 0.00 | 02-JAN-08:00 | 2352.84 | 23-FEB-11:45 |
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT | 10.63 | 0.00 | 01-JAN-00:15 | 1896.51 | 23-JUN-18:15 |
EnergyTransfer:Zone:F6 N2 APARTMENT | 15.13 | 0.04 | 10-FEB-18:15 | 2332.04 | 23-FEB-11:45 |
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT | 4.50 | 0.00 | 02-JAN-08:00 | 2332.04 | 23-FEB-11:45 |
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT | 10.63 | 0.00 | 01-JAN-00:15 | 1880.33 | 23-JUN-18:15 |
EnergyTransfer:Zone:F6 S1 APARTMENT | 17.16 | 0.01 | 13-SEP-05:45 | 2414.61 | 17-OCT-13:00 |
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT | 1.69 | 0.00 | 01-JAN-00:15 | 2000.97 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT | 15.47 | 0.00 | 01-JAN-01:15 | 2414.61 | 17-OCT-13:00 |
EnergyTransfer:Zone:F6 S2 APARTMENT | 17.16 | 0.10 | 04-OCT-16:45 | 2420.14 | 17-OCT-13:00 |
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT | 1.69 | 0.00 | 01-JAN-00:15 | 2002.92 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT | 15.47 | 0.00 | 01-JAN-01:15 | 2420.14 | 17-OCT-13:00 |
EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F7 SW APARTMENT | 22.88 | 0.11 | 13-MAR-09:15 | 3883.47 | 25-DEC-04:00 |
Heating:EnergyTransfer:Zone:F7 SW APARTMENT | 6.93 | 0.00 | 01-JAN-11:15 | 3883.47 | 25-DEC-04:00 |
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT | 15.95 | 0.00 | 01-JAN-00:15 | 3354.43 | 29-JUN-16:30 |
EnergyTransfer:Zone:F7 NW APARTMENT | 23.83 | 0.00 | 29-APR-22:30 | 4023.17 | 13-FEB-11:00 |
Heating:EnergyTransfer:Zone:F7 NW APARTMENT | 11.41 | 0.00 | 15-JAN-18:00 | 4023.17 | 13-FEB-11:00 |
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT | 12.42 | 0.00 | 01-JAN-00:15 | 3229.69 | 29-JUN-16:30 |
EnergyTransfer:Zone:F7 SE APARTMENT | 22.87 | 0.00 | 10-APR-22:30 | 3888.55 | 25-DEC-04:00 |
Heating:EnergyTransfer:Zone:F7 SE APARTMENT | 6.71 | 0.00 | 01-JAN-10:30 | 3888.55 | 25-DEC-04:00 |
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT | 16.16 | 0.00 | 01-JAN-00:15 | 2990.60 | 07-SEP-11:00 |
EnergyTransfer:Zone:F7 NE APARTMENT | 23.76 | 0.02 | 27-MAY-00:30 | 3985.49 | 25-DEC-04:00 |
Heating:EnergyTransfer:Zone:F7 NE APARTMENT | 11.10 | 0.00 | 15-JAN-18:00 | 3985.49 | 25-DEC-04:00 |
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT | 12.66 | 0.00 | 01-JAN-00:15 | 2597.19 | 02-AUG-09:00 |
EnergyTransfer:Zone:F7 N1 APARTMENT | 15.31 | 0.01 | 16-JAN-12:00 | 2527.07 | 23-FEB-11:45 |
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT | 4.97 | 0.00 | 02-JAN-20:45 | 2527.07 | 23-FEB-11:45 |
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT | 10.35 | 0.00 | 01-JAN-00:15 | 1905.02 | 23-JUN-18:15 |
EnergyTransfer:Zone:F7 N2 APARTMENT | 15.32 | 0.00 | 11-APR-10:45 | 2510.69 | 23-FEB-11:45 |
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT | 4.97 | 0.00 | 02-JAN-20:45 | 2510.69 | 23-FEB-11:45 |
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT | 10.35 | 0.00 | 01-JAN-00:15 | 1888.92 | 23-JUN-18:15 |
EnergyTransfer:Zone:F7 S1 APARTMENT | 16.90 | 0.07 | 24-SEP-11:00 | 2400.58 | 17-OCT-13:00 |
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT | 1.96 | 0.00 | 01-JAN-00:15 | 2118.18 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT | 14.94 | 0.00 | 01-JAN-00:30 | 2400.58 | 17-OCT-13:00 |
EnergyTransfer:Zone:F7 S2 APARTMENT | 16.91 | 0.02 | 09-OCT-19:00 | 2406.18 | 17-OCT-13:00 |
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT | 1.96 | 0.00 | 01-JAN-00:15 | 2120.11 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT | 14.95 | 0.00 | 01-JAN-00:30 | 2406.18 | 17-OCT-13:00 |
EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F8 SW APARTMENT | 23.23 | 0.02 | 28-OCT-09:45 | 4057.47 | 25-DEC-04:00 |
Heating:EnergyTransfer:Zone:F8 SW APARTMENT | 7.57 | 0.00 | 01-JAN-11:30 | 4057.47 | 25-DEC-04:00 |
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT | 15.66 | 0.00 | 01-JAN-00:15 | 3378.24 | 29-JUN-16:30 |
EnergyTransfer:Zone:F8 NW APARTMENT | 24.48 | 0.00 | 27-APR-19:30 | 4216.77 | 13-FEB-11:00 |
Heating:EnergyTransfer:Zone:F8 NW APARTMENT | 12.18 | 0.00 | 16-JAN-15:15 | 4216.77 | 13-FEB-11:00 |
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT | 12.30 | 0.00 | 01-JAN-00:15 | 3254.83 | 29-JUN-16:30 |
EnergyTransfer:Zone:F8 SE APARTMENT | 23.22 | 0.04 | 15-APR-03:45 | 4061.17 | 25-DEC-04:00 |
Heating:EnergyTransfer:Zone:F8 SE APARTMENT | 7.35 | 0.00 | 01-JAN-10:45 | 4061.17 | 25-DEC-04:00 |
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT | 15.87 | 0.00 | 01-JAN-00:15 | 3009.22 | 07-SEP-11:00 |
EnergyTransfer:Zone:F8 NE APARTMENT | 24.38 | 0.16 | 18-OCT-02:30 | 4153.99 | 25-DEC-04:00 |
Heating:EnergyTransfer:Zone:F8 NE APARTMENT | 11.85 | 0.00 | 15-JAN-18:00 | 4153.99 | 25-DEC-04:00 |
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT | 12.53 | 0.00 | 01-JAN-00:15 | 2618.78 | 02-AUG-09:00 |
EnergyTransfer:Zone:F8 N1 APARTMENT | 15.63 | 0.03 | 17-NOV-01:15 | 2677.44 | 23-FEB-11:45 |
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT | 5.43 | 0.00 | 02-JAN-20:45 | 2677.44 | 23-FEB-11:45 |
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT | 10.19 | 0.00 | 01-JAN-00:15 | 1944.29 | 29-JUL-15:45 |
EnergyTransfer:Zone:F8 N2 APARTMENT | 15.62 | 0.02 | 16-OCT-19:30 | 2664.37 | 23-FEB-11:45 |
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT | 5.43 | 0.00 | 02-JAN-20:45 | 2664.37 | 23-FEB-11:45 |
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT | 10.19 | 0.00 | 01-JAN-00:15 | 1939.63 | 29-JUL-15:45 |
EnergyTransfer:Zone:F8 S1 APARTMENT | 16.83 | 0.06 | 24-SEP-10:45 | 2386.63 | 17-OCT-13:00 |
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT | 2.25 | 0.00 | 01-JAN-09:30 | 2233.51 | 25-DEC-04:00 |
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT | 14.58 | 0.00 | 01-JAN-00:15 | 2386.63 | 17-OCT-13:00 |
EnergyTransfer:Zone:F8 S2 APARTMENT | 16.84 | 0.01 | 18-OCT-20:45 | 2392.22 | 17-OCT-13:00 |
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT | 2.25 | 0.00 | 01-JAN-09:30 | 2235.51 | 25-DEC-04:00 |
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT | 14.58 | 0.00 | 01-JAN-00:15 | 2392.22 | 17-OCT-13:00 |
EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F9 SW APARTMENT | 24.33 | 0.00 | 28-APR-22:15 | 4304.43 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:F9 SW APARTMENT | 8.69 | 0.00 | 01-JAN-12:00 | 4304.43 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT | 15.64 | 0.00 | 01-JAN-00:15 | 3494.59 | 29-JUN-16:30 |
EnergyTransfer:Zone:F9 NW APARTMENT | 25.99 | 0.02 | 11-APR-02:30 | 4479.61 | 13-FEB-11:00 |
Heating:EnergyTransfer:Zone:F9 NW APARTMENT | 13.50 | 0.00 | 16-JAN-15:30 | 4479.61 | 13-FEB-11:00 |
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT | 12.49 | 0.00 | 01-JAN-00:15 | 3367.61 | 29-JUN-16:30 |
EnergyTransfer:Zone:F9 SE APARTMENT | 24.26 | 0.00 | 09-MAR-18:45 | 4304.83 | 25-DEC-04:00 |
Heating:EnergyTransfer:Zone:F9 SE APARTMENT | 8.44 | 0.00 | 01-JAN-11:00 | 4304.83 | 25-DEC-04:00 |
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT | 15.82 | 0.00 | 01-JAN-00:15 | 3072.27 | 07-SEP-11:00 |
EnergyTransfer:Zone:F9 NE APARTMENT | 25.81 | 0.05 | 23-NOV-14:00 | 4385.94 | 25-DEC-04:00 |
Heating:EnergyTransfer:Zone:F9 NE APARTMENT | 13.11 | 0.00 | 16-JAN-18:15 | 4385.94 | 25-DEC-04:00 |
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT | 12.70 | 0.00 | 01-JAN-00:15 | 2709.29 | 29-JUN-16:30 |
EnergyTransfer:Zone:F9 N1 APARTMENT | 16.64 | 0.00 | 20-APR-21:00 | 2843.28 | 23-FEB-11:45 |
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT | 6.37 | 0.00 | 02-JAN-21:00 | 2843.28 | 23-FEB-11:45 |
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT | 10.27 | 0.00 | 01-JAN-00:15 | 2017.38 | 29-JUL-15:45 |
EnergyTransfer:Zone:F9 N2 APARTMENT | 16.64 | 0.02 | 14-MAY-12:30 | 2829.40 | 23-FEB-11:45 |
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT | 6.37 | 0.00 | 02-JAN-21:00 | 2829.40 | 23-FEB-11:45 |
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT | 10.27 | 0.00 | 01-JAN-00:15 | 2013.11 | 29-JUL-15:45 |
EnergyTransfer:Zone:F9 S1 APARTMENT | 17.23 | 0.02 | 23-APR-11:00 | 2441.06 | 02-OCT-13:45 |
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT | 2.86 | 0.00 | 01-JAN-10:00 | 2425.59 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT | 14.36 | 0.00 | 01-JAN-00:15 | 2441.06 | 02-OCT-13:45 |
EnergyTransfer:Zone:F9 S2 APARTMENT | 17.23 | 0.02 | 04-NOV-11:45 | 2447.72 | 02-OCT-13:45 |
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT | 2.86 | 0.00 | 01-JAN-10:00 | 2427.19 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT | 14.37 | 0.00 | 01-JAN-00:15 | 2447.72 | 02-OCT-13:45 |
EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:T SW APARTMENT | 30.28 | 0.08 | 08-OCT-23:30 | 5123.42 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 14.01 | 0.00 | 01-JAN-11:45 | 5123.42 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 16.28 | 0.00 | 01-JAN-00:15 | 4205.61 | 17-AUG-14:30 |
EnergyTransfer:Zone:T NW APARTMENT | 31.56 | 0.01 | 23-OCT-19:30 | 5176.05 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 18.27 | 0.00 | 16-JAN-15:15 | 5176.05 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 13.29 | 0.00 | 01-JAN-00:15 | 4032.69 | 29-JUN-16:15 |
EnergyTransfer:Zone:T SE APARTMENT | 29.80 | 0.01 | 07-OCT-23:00 | 5113.13 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 13.59 | 0.00 | 01-JAN-11:00 | 5113.13 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 16.21 | 0.00 | 01-JAN-00:15 | 3842.73 | 17-AUG-13:30 |
EnergyTransfer:Zone:T NE APARTMENT | 30.87 | 0.00 | 24-OCT-10:45 | 5164.01 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 17.66 | 0.00 | 26-JAN-12:00 | 5164.01 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 13.21 | 0.00 | 01-JAN-00:15 | 3220.94 | 08-JUL-10:00 |
EnergyTransfer:Zone:T N1 APARTMENT | 20.92 | 0.01 | 07-OCT-01:15 | 3263.19 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 10.22 | 0.00 | 16-JAN-15:15 | 3263.19 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 10.70 | 0.00 | 01-JAN-00:15 | 2452.81 | 29-JUN-16:30 |
EnergyTransfer:Zone:T N2 APARTMENT | 20.92 | 0.01 | 27-MAY-23:30 | 3263.22 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 10.22 | 0.00 | 16-JAN-15:30 | 3263.22 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 10.70 | 0.00 | 01-JAN-00:15 | 2429.50 | 29-JUN-16:30 |
EnergyTransfer:Zone:T S1 APARTMENT | 20.72 | 0.01 | 06-MAY-08:45 | 3200.62 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 6.63 | 0.00 | 01-JAN-10:15 | 3200.62 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 14.09 | 0.00 | 01-JAN-00:15 | 3181.26 | 02-OCT-13:45 |
EnergyTransfer:Zone:T S2 APARTMENT | 20.73 | 0.02 | 01-MAR-14:15 | 3201.02 | 25-DEC-05:00 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 6.64 | 0.00 | 01-JAN-10:15 | 3201.02 | 25-DEC-05:00 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 14.10 | 0.00 | 01-JAN-00:15 | 3178.39 | 02-OCT-13:45 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Plant | 1387.93 | 432.62 | 20-AUG-01:15 | 274457.48 | 25-DEC-06:15 |
WaterSystems:EnergyTransfer | 859.79 | 432.62 | 20-AUG-01:15 | 59797.65 | 07-FEB-07:45 |
sub cat:WaterSystems:EnergyTransfer | 859.79 | 432.62 | 20-AUG-01:15 | 59797.65 | 07-FEB-07:45 |
EnergyTransfer:HVAC | 2433.66 | 0.00 | 01-FEB-22:15 | 335697.71 | 14-SEP-10:30 |
CoolingCoils:EnergyTransfer | 1690.39 | 0.00 | 01-JAN-00:15 | 335697.71 | 14-SEP-10:30 |
HeatingCoils:EnergyTransfer | 743.27 | 0.00 | 01-FEB-14:45 | 290560.15 | 25-DEC-06:00 |
PlantLoopHeatingDemand:HVAC | 570.31 | 0.00 | 01-FEB-14:45 | 223202.96 | 25-DEC-06:00 |
HeatingCoils:PlantLoopHeatingDemand | 570.31 | 0.00 | 01-FEB-14:45 | 223202.96 | 25-DEC-06:00 |
Boilers:EnergyTransfer | 528.14 | 0.00 | 26-JAN-17:00 | 220955.06 | 25-DEC-06:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 5.338 | -10.136 | 0.000 | 0.000 | 3.815 | 1.087 | 12.213 | 20.713 | 0.000 | 0.421 | 0.000 | 0.000 | -9.317 | 0.000 | -8.557 | -15.576 |
G NW APARTMENT | 8.537 | -7.813 | 0.000 | 0.000 | 3.846 | 1.087 | 12.213 | 11.163 | 0.000 | 0.418 | 0.000 | 0.000 | -9.648 | 0.000 | -8.118 | -11.684 |
OFFICE | 3.959 | -19.528 | 0.000 | 0.000 | 0.519 | 29.882 | 9.495 | 20.720 | 0.000 | 0.261 | 0.000 | 0.000 | -9.375 | 0.000 | -5.619 | -30.314 |
G NE APARTMENT | 8.257 | -7.985 | 0.000 | 0.000 | 3.857 | 1.087 | 12.213 | 11.161 | 0.000 | 0.417 | 0.000 | 0.000 | -9.355 | 0.000 | -8.085 | -11.567 |
G N1 APARTMENT | 4.678 | -6.223 | 0.000 | 0.000 | 3.860 | 1.087 | 12.213 | 4.324 | 0.000 | 0.314 | 0.000 | 0.000 | -6.028 | 0.000 | -5.771 | -8.453 |
G N2 APARTMENT | 4.673 | -6.228 | 0.000 | 0.000 | 3.860 | 1.087 | 12.213 | 4.322 | 0.000 | 0.314 | 0.000 | 0.000 | -6.026 | 0.000 | -5.770 | -8.445 |
G S1 APARTMENT | 1.925 | -9.199 | 0.000 | 0.000 | 3.815 | 1.087 | 12.213 | 13.964 | 0.000 | 0.317 | 0.000 | 0.000 | -5.662 | 0.000 | -6.245 | -12.215 |
G S2 APARTMENT | 1.818 | -9.464 | 0.000 | 0.000 | 3.810 | 1.087 | 12.213 | 13.944 | 0.000 | 0.317 | 0.000 | 0.000 | -5.678 | 0.000 | -6.299 | -11.747 |
F2 SW APARTMENT | 4.299 | -16.301 | 0.000 | 0.000 | 3.747 | 1.087 | 12.213 | 20.041 | 0.000 | 0.563 | 0.000 | 0.000 | -10.025 | 0.000 | -11.897 | -3.726 |
F2 NW APARTMENT | 8.029 | -12.234 | 0.000 | 0.000 | 3.800 | 1.087 | 12.213 | 10.702 | 0.000 | 0.558 | 0.000 | 0.000 | -10.300 | 0.000 | -11.269 | -2.585 |
F2 SE APARTMENT | 3.666 | -17.967 | 0.000 | 0.000 | 3.738 | 1.087 | 12.213 | 20.088 | 0.000 | 0.563 | 0.000 | 0.000 | -9.951 | 0.000 | -12.049 | -1.387 |
F2 NE APARTMENT | 7.790 | -12.519 | 0.000 | 0.000 | 3.812 | 1.087 | 12.213 | 10.704 | 0.000 | 0.557 | 0.000 | 0.000 | -9.972 | 0.000 | -11.233 | -2.438 |
F2 N1 APARTMENT | 3.412 | -10.006 | 0.000 | 0.000 | 3.810 | 1.087 | 12.213 | 4.074 | 0.000 | 0.408 | 0.000 | 0.000 | -6.489 | 0.000 | -7.934 | -0.574 |
F2 N2 APARTMENT | 3.407 | -10.010 | 0.000 | 0.000 | 3.811 | 1.087 | 12.213 | 4.073 | 0.000 | 0.407 | 0.000 | 0.000 | -6.486 | 0.000 | -7.931 | -0.571 |
F2 S1 APARTMENT | 1.095 | -14.890 | 0.000 | 0.000 | 3.735 | 1.087 | 12.213 | 13.537 | 0.000 | 0.414 | 0.000 | 0.000 | -6.103 | 0.000 | -8.626 | -2.461 |
F2 S2 APARTMENT | 1.075 | -15.025 | 0.000 | 0.000 | 3.733 | 1.087 | 12.213 | 13.530 | 0.000 | 0.414 | 0.000 | 0.000 | -6.111 | 0.000 | -8.646 | -2.269 |
F3 SW APARTMENT | 4.525 | -17.109 | 0.000 | 0.000 | 3.739 | 1.087 | 12.213 | 19.793 | 0.000 | 0.675 | 0.000 | 0.000 | -10.214 | 0.000 | -13.696 | -1.012 |
F3 NW APARTMENT | 8.395 | -12.913 | 0.000 | 0.000 | 3.793 | 1.087 | 12.213 | 10.544 | 0.000 | 0.667 | 0.000 | 0.000 | -10.508 | 0.000 | -13.024 | -0.252 |
F3 SE APARTMENT | 4.276 | -17.585 | 0.000 | 0.000 | 3.742 | 1.087 | 12.213 | 19.908 | 0.000 | 0.674 | 0.000 | 0.000 | -10.043 | 0.000 | -13.722 | -0.549 |
F3 NE APARTMENT | 8.161 | -13.179 | 0.000 | 0.000 | 3.803 | 1.087 | 12.213 | 10.550 | 0.000 | 0.665 | 0.000 | 0.000 | -10.170 | 0.000 | -12.987 | -0.142 |
F3 N1 APARTMENT | 3.416 | -10.800 | 0.000 | 0.000 | 3.797 | 1.087 | 12.213 | 3.999 | 0.000 | 0.489 | 1.570 | 0.000 | -6.639 | 0.000 | -9.132 | -0.000 |
F3 N2 APARTMENT | 3.414 | -10.803 | 0.000 | 0.000 | 3.798 | 1.087 | 12.213 | 3.998 | 0.000 | 0.488 | 1.570 | 0.000 | -6.636 | 0.000 | -9.129 | -0.000 |
F3 S1 APARTMENT | 1.092 | -16.071 | 0.000 | 0.000 | 3.719 | 1.087 | 12.213 | 13.370 | 0.000 | 0.497 | 0.204 | 0.000 | -6.238 | 0.000 | -9.873 | -0.000 |
F3 S2 APARTMENT | 1.087 | -16.109 | 0.000 | 0.000 | 3.719 | 1.087 | 12.213 | 13.367 | 0.000 | 0.497 | 0.259 | 0.000 | -6.239 | 0.000 | -9.881 | -0.000 |
F4 SW APARTMENT | 5.037 | -17.103 | 0.000 | 0.000 | 3.740 | 1.087 | 12.213 | 19.648 | 0.000 | 0.739 | 0.000 | 0.000 | -10.296 | 0.000 | -14.842 | -0.222 |
F4 NW APARTMENT | 9.056 | -12.999 | 0.000 | 0.000 | 3.792 | 1.087 | 12.213 | 10.457 | 0.000 | 0.730 | 0.443 | 0.000 | -10.613 | 0.000 | -14.165 | -0.001 |
F4 SE APARTMENT | 4.861 | -17.387 | 0.000 | 0.000 | 3.746 | 1.087 | 12.213 | 19.780 | 0.000 | 0.738 | 0.000 | 0.000 | -10.104 | 0.000 | -14.844 | -0.090 |
F4 NE APARTMENT | 8.805 | -13.262 | 0.000 | 0.000 | 3.803 | 1.087 | 12.213 | 10.467 | 0.000 | 0.728 | 0.554 | 0.000 | -10.268 | 0.000 | -14.126 | -0.000 |
F4 N1 APARTMENT | 3.686 | -10.954 | 0.000 | 0.000 | 3.794 | 1.087 | 12.213 | 3.961 | 0.000 | 0.532 | 2.247 | 0.000 | -6.716 | 0.000 | -9.849 | -0.000 |
F4 N2 APARTMENT | 3.682 | -10.954 | 0.000 | 0.000 | 3.795 | 1.087 | 12.213 | 3.961 | 0.000 | 0.531 | 2.246 | 0.000 | -6.713 | 0.000 | -9.847 | -0.000 |
F4 S1 APARTMENT | 1.244 | -16.200 | 0.000 | 0.000 | 3.718 | 1.087 | 12.213 | 13.274 | 0.000 | 0.541 | 1.014 | 0.000 | -6.294 | 0.000 | -10.596 | -0.000 |
F4 S2 APARTMENT | 1.242 | -16.209 | 0.000 | 0.000 | 3.718 | 1.087 | 12.213 | 13.272 | 0.000 | 0.542 | 1.029 | 0.000 | -6.294 | 0.000 | -10.600 | -0.000 |
M SW APARTMENT | 5.487 | -17.163 | 0.000 | 0.000 | 3.743 | 1.087 | 12.213 | 19.536 | 0.000 | 0.789 | 0.582 | 0.000 | -10.361 | 0.000 | -15.912 | -0.001 |
M NW APARTMENT | 9.585 | -13.188 | 0.000 | 0.000 | 3.793 | 1.087 | 12.213 | 10.390 | 0.000 | 0.779 | 1.255 | 0.000 | -10.697 | 0.000 | -15.216 | -0.000 |
M SE APARTMENT | 5.312 | -17.408 | 0.000 | 0.000 | 3.749 | 1.087 | 12.213 | 19.674 | 0.000 | 0.788 | 0.656 | 0.000 | -10.162 | 0.000 | -15.908 | -0.000 |
M NE APARTMENT | 9.318 | -13.446 | 0.000 | 0.000 | 3.803 | 1.087 | 12.213 | 10.402 | 0.000 | 0.777 | 1.369 | 0.000 | -10.347 | 0.000 | -15.175 | -0.000 |
M N1 APARTMENT | 3.907 | -11.183 | 0.000 | 0.000 | 3.794 | 1.087 | 12.213 | 3.933 | 0.000 | 0.564 | 3.010 | 0.000 | -6.776 | 0.000 | -10.548 | -0.000 |
M N2 APARTMENT | 3.902 | -11.184 | 0.000 | 0.000 | 3.794 | 1.087 | 12.213 | 3.932 | 0.000 | 0.564 | 3.010 | 0.000 | -6.773 | 0.000 | -10.545 | -0.000 |
M S1 APARTMENT | 1.380 | -16.321 | 0.000 | 0.000 | 3.719 | 1.087 | 12.213 | 13.201 | 0.000 | 0.575 | 1.795 | 0.000 | -6.336 | 0.000 | -11.312 | -0.000 |
M S2 APARTMENT | 1.383 | -16.325 | 0.000 | 0.000 | 3.719 | 1.087 | 12.213 | 13.199 | 0.000 | 0.575 | 1.799 | 0.000 | -6.335 | 0.000 | -11.315 | -0.000 |
F6 SW APARTMENT | 6.265 | -16.398 | 0.000 | 0.000 | 3.752 | 1.087 | 12.213 | 19.481 | 0.000 | 0.831 | 0.002 | 0.000 | -10.356 | 0.000 | -16.756 | -0.119 |
F6 NW APARTMENT | 10.604 | -12.675 | 0.000 | 0.000 | 3.801 | 1.087 | 12.213 | 10.369 | 0.000 | 0.821 | 0.530 | 0.000 | -10.707 | 0.000 | -16.042 | -0.000 |
F6 SE APARTMENT | 6.072 | -16.623 | 0.000 | 0.000 | 3.758 | 1.087 | 12.213 | 19.624 | 0.000 | 0.831 | 0.000 | 0.000 | -10.154 | 0.000 | -16.751 | -0.056 |
F6 NE APARTMENT | 10.315 | -12.924 | 0.000 | 0.000 | 3.811 | 1.087 | 12.213 | 10.384 | 0.000 | 0.818 | 0.647 | 0.000 | -10.354 | 0.000 | -15.997 | -0.000 |
F6 N1 APARTMENT | 4.500 | -10.633 | 0.000 | 0.000 | 3.802 | 1.087 | 12.213 | 3.931 | 0.000 | 0.592 | 2.355 | 0.000 | -6.782 | 0.000 | -11.064 | -0.000 |
F6 N2 APARTMENT | 4.496 | -10.633 | 0.000 | 0.000 | 3.802 | 1.087 | 12.213 | 3.930 | 0.000 | 0.592 | 2.354 | 0.000 | -6.779 | 0.000 | -11.061 | -0.000 |
F6 S1 APARTMENT | 1.687 | -15.468 | 0.000 | 0.000 | 3.729 | 1.087 | 12.213 | 13.165 | 0.000 | 0.604 | 1.163 | 0.000 | -6.330 | 0.000 | -11.849 | -0.000 |
F6 S2 APARTMENT | 1.687 | -15.469 | 0.000 | 0.000 | 3.729 | 1.087 | 12.213 | 13.164 | 0.000 | 0.604 | 1.166 | 0.000 | -6.329 | 0.000 | -11.852 | -0.000 |
F7 SW APARTMENT | 6.925 | -15.950 | 0.000 | 0.000 | 3.759 | 1.087 | 12.213 | 19.427 | 0.000 | 0.867 | 0.002 | 0.000 | -10.362 | 0.000 | -17.513 | -0.451 |
F7 NW APARTMENT | 11.410 | -12.419 | 0.000 | 0.000 | 3.806 | 1.087 | 12.213 | 10.344 | 0.000 | 0.856 | 0.216 | 0.000 | -10.727 | 0.000 | -16.786 | -0.000 |
F7 SE APARTMENT | 6.713 | -16.161 | 0.000 | 0.000 | 3.765 | 1.087 | 12.213 | 19.574 | 0.000 | 0.866 | 0.001 | 0.000 | -10.158 | 0.000 | -17.508 | -0.390 |
F7 NE APARTMENT | 11.100 | -12.659 | 0.000 | 0.000 | 3.817 | 1.087 | 12.213 | 10.362 | 0.000 | 0.853 | 0.336 | 0.000 | -10.371 | 0.000 | -16.737 | -0.000 |
F7 N1 APARTMENT | 4.967 | -10.345 | 0.000 | 0.000 | 3.807 | 1.087 | 12.213 | 3.925 | 0.000 | 0.616 | 2.060 | 0.000 | -6.794 | 0.000 | -11.535 | -0.000 |
F7 N2 APARTMENT | 4.965 | -10.350 | 0.000 | 0.000 | 3.808 | 1.087 | 12.213 | 3.924 | 0.000 | 0.615 | 2.060 | 0.000 | -6.791 | 0.000 | -11.531 | -0.000 |
F7 S1 APARTMENT | 1.959 | -14.944 | 0.000 | 0.000 | 3.737 | 1.087 | 12.213 | 13.131 | 0.000 | 0.628 | 0.855 | 0.000 | -6.331 | 0.000 | -12.333 | -0.000 |
F7 S2 APARTMENT | 1.962 | -14.946 | 0.000 | 0.000 | 3.737 | 1.087 | 12.213 | 13.129 | 0.000 | 0.628 | 0.857 | 0.000 | -6.330 | 0.000 | -12.336 | -0.000 |
F8 SW APARTMENT | 7.569 | -15.657 | 0.000 | 0.000 | 3.765 | 1.087 | 12.213 | 19.379 | 0.000 | 0.904 | 0.002 | 0.000 | -10.370 | 0.000 | -18.211 | -0.679 |
F8 NW APARTMENT | 12.181 | -12.298 | 0.000 | 0.000 | 3.811 | 1.087 | 12.213 | 10.319 | 0.000 | 0.892 | 0.020 | 0.000 | -10.748 | 0.000 | -17.476 | -0.000 |
F8 SE APARTMENT | 7.349 | -15.866 | 0.000 | 0.000 | 3.771 | 1.087 | 12.213 | 19.528 | 0.000 | 0.903 | 0.001 | 0.000 | -10.164 | 0.000 | -18.206 | -0.613 |
F8 NE APARTMENT | 11.850 | -12.527 | 0.000 | 0.000 | 3.821 | 1.087 | 12.213 | 10.340 | 0.000 | 0.889 | 0.140 | 0.000 | -10.389 | 0.000 | -17.424 | -0.000 |
F8 N1 APARTMENT | 5.434 | -10.191 | 0.000 | 0.000 | 3.812 | 1.087 | 12.213 | 3.918 | 0.000 | 0.642 | 1.871 | 0.000 | -6.807 | 0.000 | -11.978 | -0.000 |
F8 N2 APARTMENT | 5.430 | -10.193 | 0.000 | 0.000 | 3.813 | 1.087 | 12.213 | 3.917 | 0.000 | 0.642 | 1.872 | 0.000 | -6.804 | 0.000 | -11.975 | -0.000 |
F8 S1 APARTMENT | 2.253 | -14.581 | 0.000 | 0.000 | 3.744 | 1.087 | 12.213 | 13.100 | 0.000 | 0.655 | 0.646 | 0.000 | -6.333 | 0.000 | -12.783 | -0.000 |
F8 S2 APARTMENT | 2.253 | -14.582 | 0.000 | 0.000 | 3.744 | 1.087 | 12.213 | 13.098 | 0.000 | 0.655 | 0.649 | 0.000 | -6.331 | 0.000 | -12.786 | -0.000 |
F9 SW APARTMENT | 8.693 | -15.636 | 0.000 | 0.000 | 3.771 | 1.087 | 12.213 | 19.349 | 0.000 | 0.939 | 0.001 | 0.000 | -10.359 | 0.000 | -18.820 | -1.235 |
F9 NW APARTMENT | 13.500 | -12.485 | 0.000 | 0.000 | 3.814 | 1.087 | 12.213 | 10.301 | 0.000 | 0.926 | 0.000 | 0.000 | -10.754 | 0.000 | -18.099 | -0.502 |
F9 SE APARTMENT | 8.439 | -15.824 | 0.000 | 0.000 | 3.777 | 1.087 | 12.213 | 19.499 | 0.000 | 0.938 | 0.001 | 0.000 | -10.153 | 0.000 | -18.819 | -1.157 |
F9 NE APARTMENT | 13.112 | -12.696 | 0.000 | 0.000 | 3.825 | 1.087 | 12.213 | 10.323 | 0.000 | 0.923 | 0.000 | 0.000 | -10.393 | 0.000 | -18.041 | -0.353 |
F9 N1 APARTMENT | 6.371 | -10.270 | 0.000 | 0.000 | 3.816 | 1.087 | 12.213 | 3.912 | 0.000 | 0.667 | 1.389 | 0.000 | -6.807 | 0.000 | -12.376 | -0.000 |
F9 N2 APARTMENT | 6.365 | -10.273 | 0.000 | 0.000 | 3.817 | 1.087 | 12.213 | 3.911 | 0.000 | 0.667 | 1.391 | 0.000 | -6.804 | 0.000 | -12.373 | -0.000 |
F9 S1 APARTMENT | 2.863 | -14.364 | 0.000 | 0.000 | 3.752 | 1.087 | 12.213 | 13.082 | 0.000 | 0.681 | 0.170 | 0.000 | -6.321 | 0.000 | -13.163 | -0.000 |
F9 S2 APARTMENT | 2.863 | -14.366 | 0.000 | 0.000 | 3.753 | 1.087 | 12.213 | 13.080 | 0.000 | 0.681 | 0.175 | 0.000 | -6.319 | 0.000 | -13.166 | -0.000 |
T SW APARTMENT | 14.005 | -16.278 | 0.000 | 0.000 | 3.798 | 1.087 | 12.213 | 19.084 | 0.000 | 0.963 | 0.000 | 0.000 | -9.923 | 0.000 | -19.397 | -5.551 |
T NW APARTMENT | 18.266 | -13.293 | 0.000 | 0.000 | 3.830 | 1.087 | 12.213 | 10.089 | 0.000 | 0.949 | 0.000 | 0.000 | -10.388 | 0.000 | -18.715 | -4.037 |
T SE APARTMENT | 13.588 | -16.211 | 0.000 | 0.000 | 3.805 | 1.087 | 12.213 | 19.253 | 0.000 | 0.962 | 0.000 | 0.000 | -9.737 | 0.000 | -19.401 | -5.559 |
T NE APARTMENT | 17.659 | -13.210 | 0.000 | 0.000 | 3.841 | 1.087 | 12.213 | 10.141 | 0.000 | 0.948 | 0.000 | 0.000 | -10.055 | 0.000 | -18.664 | -3.958 |
T N1 APARTMENT | 10.221 | -10.698 | 0.000 | 0.000 | 3.831 | 1.087 | 12.213 | 3.836 | 0.000 | 0.687 | 0.000 | 0.000 | -6.565 | 0.000 | -12.774 | -1.837 |
T N2 APARTMENT | 10.219 | -10.697 | 0.000 | 0.000 | 3.832 | 1.087 | 12.213 | 3.834 | 0.000 | 0.687 | 0.000 | 0.000 | -6.561 | 0.000 | -12.775 | -1.838 |
T S1 APARTMENT | 6.631 | -14.085 | 0.000 | 0.000 | 3.782 | 1.087 | 12.213 | 12.941 | 0.000 | 0.701 | 0.000 | 0.000 | -6.083 | 0.000 | -13.539 | -3.647 |
T S2 APARTMENT | 6.637 | -14.095 | 0.000 | 0.000 | 3.783 | 1.087 | 12.213 | 12.937 | 0.000 | 0.701 | 0.000 | 0.000 | -6.080 | 0.000 | -13.544 | -3.638 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 4.643 | 0.000 | 1.968 | 28.309 | 0.000 | -2.102 | 0.000 | -49.258 | -0.001 |
F2 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.102 | 0.000 | 0.031 | 0.000 | 0.000 | -1.288 | 0.000 | -1.456 | -15.829 |
F3 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.058 | 0.000 | 0.035 | 0.000 | 0.000 | -1.342 | 0.000 | -1.776 | -15.415 |
F4 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.035 | 0.000 | 0.037 | 0.000 | 0.000 | -1.365 | 0.000 | -2.004 | -15.142 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32.880 | 0.000 | 2.007 | 0.000 | 0.033 | 0.000 | 0.000 | -1.400 | 0.000 | -2.269 | -31.250 |
F6 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.017 | 0.000 | 0.043 | 0.000 | 0.000 | -1.375 | 0.000 | -2.318 | -14.807 |
F7 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.018 | 0.000 | 0.046 | 0.000 | 0.000 | -1.367 | 0.000 | -2.426 | -14.710 |
F8 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.014 | 0.000 | 0.048 | 0.000 | 0.000 | -1.366 | 0.000 | -2.532 | -14.604 |
F9 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.011 | 0.000 | 0.047 | 0.000 | 0.000 | -1.364 | 0.000 | -2.623 | -14.512 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 8.151 | 1.955 | 0.000 | 0.023 | 0.000 | 0.000 | -1.328 | 0.000 | -2.797 | -22.444 |
Total Facility | 493.587 | -1070.360 | 0.000 | 0.000 | 299.427 | 296.560 | 982.450 | 971.570 | 0.000 | 54.944 | 75.855 | 0.000 | -679.493 | 0.000 | -1101.910 | -322.627 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 17-AUG-16:30 | 0.00 | -2559.67 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2774.47 | 0.00 | 97.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1050.54 |
G NW APARTMENT | 10-JUL-17:10 | 0.00 | -2392.88 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 2686.91 | 0.00 | 117.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1229.73 |
OFFICE | 29-AUG-13:15 | 0.00 | -3800.20 | 0.00 | 0.00 | 65.10 | 2345.88 | 588.62 | 2994.78 | 0.00 | 114.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2309.12 |
G NE APARTMENT | 11-JUL-07:45 | 0.00 | -1824.56 | 0.00 | 0.00 | 63.58 | 19.46 | 388.49 | 2820.85 | 0.00 | 220.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1688.71 |
G N1 APARTMENT | 10-JUL-17:45 | 0.00 | -1262.86 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 678.44 | 0.00 | 60.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -294.47 |
G N2 APARTMENT | 10-JUL-17:45 | 0.00 | -1247.79 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 678.77 | 0.00 | 60.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -309.86 |
G S1 APARTMENT | 07-SEP-14:00 | 0.00 | -1730.27 | 0.00 | 0.00 | 40.48 | 12.97 | 382.60 | 2223.51 | 0.00 | 31.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -960.63 |
G S2 APARTMENT | 07-SEP-14:00 | 0.00 | -1798.50 | 0.00 | 0.00 | 40.56 | 12.97 | 382.60 | 2223.01 | 0.00 | 31.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -892.23 |
F2 SW APARTMENT | 17-AUG-16:30 | 0.00 | -3215.02 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2759.82 | 0.00 | 139.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -422.89 |
F2 NW APARTMENT | 29-JUN-16:30 | 0.00 | -3030.34 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2758.47 | 0.00 | 332.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -798.52 |
F2 SE APARTMENT | 29-AUG-13:45 | 0.00 | -3074.65 | 0.00 | 0.00 | 40.49 | 12.97 | 382.60 | 2689.93 | 0.00 | 145.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -196.67 |
F2 NE APARTMENT | 11-JUL-07:45 | 0.00 | -2391.27 | 0.00 | 0.00 | 63.58 | 19.46 | 388.49 | 2791.44 | 0.00 | 244.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1115.96 |
F2 N1 APARTMENT | 23-JUN-18:15 | 0.00 | -1714.04 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 556.62 | 0.00 | 363.93 | 0.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 N2 APARTMENT | 02-JUN-17:30 | 0.00 | -1701.21 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 265.33 | 0.00 | 493.35 | 124.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 S1 APARTMENT | 07-SEP-14:00 | 0.00 | -2268.40 | 0.00 | 0.00 | 40.62 | 12.97 | 382.60 | 2204.40 | 0.00 | 45.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -417.50 |
F2 S2 APARTMENT | 07-SEP-14:00 | 0.00 | -2289.80 | 0.00 | 0.00 | 40.66 | 12.97 | 382.60 | 2204.39 | 0.00 | 45.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -396.26 |
F3 SW APARTMENT | 29-JUN-16:30 | 0.00 | -3245.83 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2686.03 | 0.00 | 392.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -570.82 |
F3 NW APARTMENT | 29-JUN-16:30 | 0.00 | -3112.34 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2744.39 | 0.00 | 392.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -762.68 |
F3 SE APARTMENT | 07-SEP-11:00 | 0.00 | -2936.83 | 0.00 | 0.00 | 40.27 | 12.97 | 412.03 | 3419.70 | 0.00 | 266.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1214.96 |
F3 NE APARTMENT | 02-AUG-09:00 | 0.00 | -2480.30 | 0.00 | 0.00 | 40.76 | 12.97 | 394.37 | 2485.37 | 0.00 | 525.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -979.15 |
F3 N1 APARTMENT | 23-JUN-18:15 | 0.00 | -1807.08 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 552.72 | 0.00 | 407.65 | 53.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 N2 APARTMENT | 23-JUN-18:15 | 0.00 | -1790.67 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 553.06 | 0.00 | 407.65 | 36.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 S1 APARTMENT | 17-OCT-13:00 | 0.00 | -2350.45 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2591.87 | 0.00 | 318.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1002.43 |
F3 S2 APARTMENT | 17-OCT-13:00 | 0.00 | -2357.56 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2591.74 | 0.00 | 318.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -995.18 |
F4 SW APARTMENT | 29-JUN-16:30 | 0.00 | -3291.65 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2677.40 | 0.00 | 437.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -561.63 |
F4 NW APARTMENT | 29-JUN-16:30 | 0.00 | -3161.40 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2734.65 | 0.00 | 437.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -749.14 |
F4 SE APARTMENT | 07-SEP-11:00 | 0.00 | -2951.44 | 0.00 | 0.00 | 40.29 | 12.97 | 412.03 | 3405.90 | 0.00 | 280.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1200.29 |
F4 NE APARTMENT | 02-AUG-09:00 | 0.00 | -2529.38 | 0.00 | 0.00 | 40.76 | 12.97 | 394.37 | 2471.01 | 0.00 | 572.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -962.38 |
F4 N1 APARTMENT | 23-JUN-18:15 | 0.00 | -1852.28 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 550.35 | 0.00 | 440.34 | 68.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 N2 APARTMENT | 23-JUN-18:15 | 0.00 | -1835.94 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 550.69 | 0.00 | 440.34 | 51.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 S1 APARTMENT | 17-OCT-13:00 | 0.00 | -2402.05 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2573.90 | 0.00 | 348.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -962.12 |
F4 S2 APARTMENT | 17-OCT-13:00 | 0.00 | -2407.67 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2573.79 | 0.00 | 348.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -956.39 |
M SW APARTMENT | 29-JUN-16:30 | 0.00 | -3348.84 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2669.96 | 0.00 | 474.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -533.93 |
M NW APARTMENT | 29-JUN-16:30 | 0.00 | -3221.53 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2726.42 | 0.00 | 474.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -717.72 |
M SE APARTMENT | 07-SEP-11:00 | 0.00 | -2998.24 | 0.00 | 0.00 | 40.33 | 12.97 | 412.03 | 3394.29 | 0.00 | 293.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1154.69 |
M NE APARTMENT | 02-AUG-09:00 | 0.00 | -2589.49 | 0.00 | 0.00 | 40.76 | 12.97 | 394.37 | 2459.12 | 0.00 | 609.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -927.69 |
M N1 APARTMENT | 23-JUN-18:15 | 0.00 | -1905.44 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 548.09 | 0.00 | 466.55 | 97.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 23-JUN-18:15 | 0.00 | -1889.14 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 548.43 | 0.00 | 466.55 | 81.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | 17-OCT-13:00 | 0.00 | -2443.21 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2560.15 | 0.00 | 370.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -929.35 |
M S2 APARTMENT | 17-OCT-13:00 | 0.00 | -2448.64 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2560.04 | 0.00 | 370.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -923.81 |
F6 SW APARTMENT | 29-JUN-16:30 | 0.00 | -3342.47 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2665.32 | 0.00 | 506.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -567.18 |
F6 NW APARTMENT | 29-JUN-16:30 | 0.00 | -3216.07 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2721.11 | 0.00 | 506.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -749.38 |
F6 SE APARTMENT | 07-SEP-11:00 | 0.00 | -2983.69 | 0.00 | 0.00 | 40.37 | 12.97 | 412.03 | 3386.20 | 0.00 | 304.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1172.21 |
F6 NE APARTMENT | 02-AUG-09:00 | 0.00 | -2584.24 | 0.00 | 0.00 | 40.76 | 12.97 | 394.37 | 2450.96 | 0.00 | 640.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -955.79 |
F6 N1 APARTMENT | 23-JUN-18:15 | 0.00 | -1896.47 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 547.26 | 0.00 | 488.37 | 67.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 N2 APARTMENT | 23-JUN-18:15 | 0.00 | -1880.28 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 547.60 | 0.00 | 488.37 | 51.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 S1 APARTMENT | 17-OCT-13:00 | 0.00 | -2414.09 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2550.69 | 0.00 | 387.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -966.38 |
F6 S2 APARTMENT | 17-OCT-13:00 | 0.00 | -2419.62 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2550.58 | 0.00 | 387.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -960.73 |
F7 SW APARTMENT | 29-JUN-16:30 | 0.00 | -3354.68 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2660.75 | 0.00 | 533.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -578.07 |
F7 NW APARTMENT | 29-JUN-16:30 | 0.00 | -3229.91 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2716.00 | 0.00 | 533.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -758.09 |
F7 SE APARTMENT | 07-SEP-11:00 | 0.00 | -2989.16 | 0.00 | 0.00 | 40.40 | 12.97 | 412.03 | 3378.71 | 0.00 | 314.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1169.05 |
F7 NE APARTMENT | 02-AUG-09:00 | 0.00 | -2596.88 | 0.00 | 0.00 | 40.76 | 12.97 | 394.37 | 2443.41 | 0.00 | 667.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -961.99 |
F7 N1 APARTMENT | 23-JUN-18:15 | 0.00 | -1904.97 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 546.15 | 0.00 | 506.92 | 58.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 N2 APARTMENT | 23-JUN-18:15 | 0.00 | -1888.86 | 0.00 | 0.00 | 141.83 | 103.77 | 547.42 | 546.49 | 0.00 | 506.92 | 42.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 S1 APARTMENT | 17-OCT-13:00 | 0.00 | -2400.05 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2542.13 | 0.00 | 401.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -985.68 |
F7 S2 APARTMENT | 17-OCT-13:00 | 0.00 | -2405.65 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2542.02 | 0.00 | 401.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -979.96 |
F8 SW APARTMENT | 29-JUN-16:30 | 0.00 | -3378.49 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2656.29 | 0.00 | 558.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -574.53 |
F8 NW APARTMENT | 29-JUN-16:30 | 0.00 | -3255.04 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 2711.08 | 0.00 | 558.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -752.77 |
F8 SE APARTMENT | 07-SEP-11:00 | 0.00 | -3007.74 | 0.00 | 0.00 | 40.45 | 12.97 | 412.03 | 3371.94 | 0.00 | 323.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1153.26 |
F8 NE APARTMENT | 02-AUG-09:00 | 0.00 | -2618.47 | 0.00 | 0.00 | 40.76 | 12.97 | 394.37 | 2436.40 | 0.00 | 690.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -956.18 |
F8 N1 APARTMENT | 29-JUL-15:45 | 0.00 | -1945.27 | 0.00 | 0.00 | 48.90 | 45.40 | 470.89 | 449.00 | 0.00 | 835.79 | 95.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 N2 APARTMENT | 29-JUL-15:45 | 0.00 | -1940.62 | 0.00 | 0.00 | 48.90 | 45.40 | 470.89 | 449.08 | 0.00 | 835.80 | 90.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 S1 APARTMENT | 17-OCT-13:00 | 0.00 | -2386.10 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2534.77 | 0.00 | 412.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1003.36 |
F8 S2 APARTMENT | 17-OCT-13:00 | 0.00 | -2391.68 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2534.66 | 0.00 | 412.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -997.65 |
F9 SW APARTMENT | 29-JUN-16:30 | 0.00 | -3494.84 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 2649.22 | 0.00 | 580.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -473.54 |
F9 NW APARTMENT | 29-JUN-16:30 | 0.00 | -3367.83 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 2703.60 | 0.00 | 580.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -654.94 |
F9 SE APARTMENT | 07-SEP-11:00 | 0.00 | -3070.76 | 0.00 | 0.00 | 40.62 | 12.97 | 412.03 | 3366.39 | 0.00 | 339.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1100.28 |
F9 NE APARTMENT | 29-JUN-16:30 | 0.00 | -2709.52 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 1045.79 | 0.00 | 580.93 | 344.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 N1 APARTMENT | 29-JUL-15:45 | 0.00 | -2018.43 | 0.00 | 0.00 | 48.90 | 45.40 | 470.89 | 446.69 | 0.00 | 861.03 | 145.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 N2 APARTMENT | 29-JUL-15:45 | 0.00 | -2014.17 | 0.00 | 0.00 | 48.90 | 45.40 | 470.89 | 446.75 | 0.00 | 861.03 | 141.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 S1 APARTMENT | 02-OCT-13:45 | 0.00 | -2443.13 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 2349.83 | 0.00 | 661.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1004.73 |
F9 S2 APARTMENT | 02-OCT-13:45 | 0.00 | -2449.79 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 2349.81 | 0.00 | 662.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -999.26 |
T SW APARTMENT | 17-AUG-14:30 | 0.00 | -4205.92 | 0.00 | 0.00 | 40.75 | 22.70 | 400.26 | 3232.64 | 0.00 | 473.51 | 36.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 29-JUN-16:10 | 0.00 | -4034.37 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 2693.24 | 0.00 | 617.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -14.66 |
T SE APARTMENT | 17-AUG-13:30 | 0.00 | -3842.47 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 2420.22 | 0.00 | 414.84 | 571.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 08-JUL-10:00 | 0.00 | -3220.85 | 0.00 | 0.00 | 40.76 | 12.97 | 406.15 | 2288.61 | 0.00 | 300.22 | 172.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 29-JUN-16:30 | 0.00 | -2453.02 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 646.92 | 0.00 | 362.76 | 705.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 29-JUN-16:10 | 0.00 | -2430.32 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 646.94 | 0.00 | 372.48 | 672.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 02-OCT-13:45 | 0.00 | -3183.92 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 2322.20 | 0.00 | 710.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -285.45 |
T S2 APARTMENT | 02-OCT-13:45 | 0.00 | -3181.05 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 2322.22 | 0.00 | 710.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -288.34 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 29-JUN-16:30 | 0.00 | -191190.62 | 0.00 | 0.00 | 6696.25 | 11327.17 | 47312.53 | 103685.66 | 0.00 | 34116.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -11947.60 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 25-DEC-05:00 | 2308.92 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1327.65 | 0.00 | -1267.35 | -146.72 |
G NW APARTMENT | 25-DEC-08:30 | 2547.62 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1108.16 | 0.00 | -1201.36 | -720.02 |
OFFICE | 25-DEC-07:05 | 2351.68 | 0.00 | 0.00 | 0.00 | 0.00 | 469.18 | 194.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1366.19 | 0.00 | -1227.52 | -421.39 |
G NE APARTMENT | 25-DEC-05:00 | 2329.81 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1327.43 | 0.00 | -1267.35 | -167.84 |
G N1 APARTMENT | 25-DEC-08:30 | 1586.65 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -676.46 | 0.00 | -724.63 | -667.47 |
G N2 APARTMENT | 25-DEC-08:30 | 1582.50 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -676.53 | 0.00 | -724.63 | -663.25 |
G S1 APARTMENT | 12-MAR-09:55 | 1645.85 | 0.00 | 0.00 | 0.00 | 46.09 | 12.97 | 406.15 | 1504.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1617.44 | -1997.87 |
G S2 APARTMENT | 12-MAR-09:55 | 1678.92 | 0.00 | 0.00 | 0.00 | 45.98 | 12.97 | 406.15 | 1503.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1617.80 | -2029.30 |
F2 SW APARTMENT | 25-DEC-05:00 | 2791.30 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1370.75 | 0.00 | -1822.40 | -30.95 |
F2 NW APARTMENT | 25-DEC-05:00 | 2872.10 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1382.52 | 0.00 | -1822.40 | -99.98 |
F2 SE APARTMENT | 25-DEC-05:00 | 2775.80 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1360.49 | 0.00 | -1822.40 | -25.71 |
F2 NE APARTMENT | 25-DEC-05:00 | 2872.81 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1371.70 | 0.00 | -1822.40 | -111.51 |
F2 N1 APARTMENT | 12-MAR-09:55 | 2018.93 | 0.00 | 0.00 | 0.00 | 46.57 | 12.97 | 406.15 | 267.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2097.49 | -655.05 |
F2 N2 APARTMENT | 12-MAR-09:55 | 2015.64 | 0.00 | 0.00 | 0.00 | 46.57 | 12.97 | 406.15 | 267.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2097.48 | -651.67 |
F2 S1 APARTMENT | 25-DEC-05:00 | 1510.94 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -830.29 | 0.00 | -1099.23 | -14.22 |
F2 S2 APARTMENT | 25-DEC-05:00 | 1510.75 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -830.30 | 0.00 | -1099.23 | -14.03 |
F3 SW APARTMENT | 25-DEC-05:00 | 3052.00 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 63.21 | 0.00 | -1389.50 | 0.00 | -2158.51 | 0.00 |
F3 NW APARTMENT | 25-DEC-05:00 | 3147.21 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1404.71 | 0.00 | -2158.51 | -16.79 |
F3 SE APARTMENT | 25-DEC-05:00 | 3055.35 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 46.14 | 0.00 | -1375.78 | 0.00 | -2158.51 | 0.00 |
F3 NE APARTMENT | 25-DEC-05:00 | 3147.04 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1391.21 | 0.00 | -2158.51 | -30.12 |
F3 N1 APARTMENT | 12-MAR-09:55 | 2340.99 | 0.00 | 0.00 | 0.00 | 46.26 | 12.97 | 406.15 | 255.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2410.83 | -650.61 |
F3 N2 APARTMENT | 12-MAR-09:55 | 2336.71 | 0.00 | 0.00 | 0.00 | 46.26 | 12.97 | 406.15 | 255.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2410.81 | -646.33 |
F3 S1 APARTMENT | 12-MAR-10:00 | 1677.96 | 0.00 | 0.00 | 0.00 | 43.00 | 12.97 | 406.15 | 1394.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2413.34 | -1121.38 |
F3 S2 APARTMENT | 12-MAR-10:00 | 1682.48 | 0.00 | 0.00 | 0.00 | 42.95 | 12.97 | 406.15 | 1394.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2413.46 | -1125.12 |
F4 SW APARTMENT | 25-DEC-05:00 | 3289.85 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 92.24 | 0.00 | -1401.24 | 0.00 | -2413.65 | 0.00 |
F4 NW APARTMENT | 25-DEC-05:00 | 3390.94 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 8.00 | 0.00 | -1418.10 | 0.00 | -2413.65 | 0.00 |
F4 SE APARTMENT | 25-DEC-05:00 | 3295.94 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 71.01 | 0.00 | -1386.10 | 0.00 | -2413.65 | 0.00 |
F4 NE APARTMENT | 25-DEC-05:00 | 3390.04 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1403.34 | 0.00 | -2413.65 | -5.85 |
F4 N1 APARTMENT | 23-FEB-11:40 | 2165.71 | 0.00 | 0.00 | 0.00 | 47.05 | 12.97 | 412.03 | 251.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2404.12 | -484.93 |
F4 N2 APARTMENT | 23-FEB-11:40 | 2178.45 | 0.00 | 0.00 | 0.00 | 46.99 | 12.97 | 412.03 | 250.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2404.21 | -496.69 |
F4 S1 APARTMENT | 25-DEC-05:00 | 1753.68 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 116.95 | 0.00 | -847.58 | 0.00 | -1455.85 | 0.00 |
F4 S2 APARTMENT | 25-DEC-05:00 | 1755.50 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 115.07 | 0.00 | -847.53 | 0.00 | -1455.85 | 0.00 |
M SW APARTMENT | 25-DEC-05:00 | 3480.51 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 121.14 | 0.00 | -1410.29 | 0.00 | -2624.16 | 0.00 |
M NW APARTMENT | 25-DEC-05:00 | 3582.19 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 37.75 | 0.00 | -1428.59 | 0.00 | -2624.16 | 0.00 |
M SE APARTMENT | 25-DEC-05:00 | 3486.39 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 99.07 | 0.00 | -1394.10 | 0.00 | -2624.16 | 0.00 |
M NE APARTMENT | 25-DEC-04:00 | 3580.86 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 59.55 | 0.00 | -1387.00 | 0.00 | -2673.25 | 0.00 |
M N1 APARTMENT | 23-FEB-11:40 | 2325.63 | 0.00 | 0.00 | 0.00 | 47.05 | 12.97 | 412.03 | 248.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2590.25 | -456.19 |
M N2 APARTMENT | 23-FEB-11:40 | 2337.98 | 0.00 | 0.00 | 0.00 | 47.00 | 12.97 | 412.03 | 247.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2590.34 | -467.57 |
M S1 APARTMENT | 25-DEC-05:00 | 1859.19 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 143.49 | 0.00 | -852.66 | 0.00 | -1582.83 | 0.00 |
M S2 APARTMENT | 25-DEC-05:00 | 1861.06 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 141.56 | 0.00 | -852.60 | 0.00 | -1582.83 | 0.00 |
F6 SW APARTMENT | 25-DEC-05:00 | 3700.32 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 88.12 | 0.00 | -1415.49 | 0.00 | -2805.74 | 0.00 |
F6 NW APARTMENT | 13-FEB-10:53 | 3814.81 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -478.80 | 0.00 | -3277.00 | -525.55 |
F6 SE APARTMENT | 25-DEC-05:00 | 3705.17 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 66.34 | 0.00 | -1398.58 | 0.00 | -2805.74 | 0.00 |
F6 NE APARTMENT | 25-DEC-04:00 | 3802.67 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 28.31 | 0.00 | -1392.55 | 0.00 | -2858.27 | 0.00 |
F6 N1 APARTMENT | 10-NOV-14:10 | 2429.27 | 0.00 | 0.00 | 0.00 | 45.55 | 12.97 | 382.60 | 163.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2155.68 | -877.93 |
F6 N2 APARTMENT | 23-FEB-11:40 | 2421.39 | 0.00 | 0.00 | 0.00 | 47.23 | 12.97 | 412.03 | 248.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2753.86 | -388.12 |
F6 S1 APARTMENT | 25-DEC-05:00 | 2000.87 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 113.97 | 0.00 | -855.30 | 0.00 | -1692.35 | 0.00 |
F6 S2 APARTMENT | 25-DEC-05:00 | 2002.83 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 111.96 | 0.00 | -855.24 | 0.00 | -1692.35 | 0.00 |
F7 SW APARTMENT | 25-DEC-05:00 | 3883.25 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 71.05 | 0.00 | -1420.31 | 0.00 | -2966.79 | 0.00 |
F7 NW APARTMENT | 13-FEB-10:53 | 4023.07 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -485.23 | 0.00 | -3465.60 | -538.77 |
F7 SE APARTMENT | 25-DEC-04:00 | 3888.24 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 91.01 | 0.00 | -1376.71 | 0.00 | -3022.37 | 0.00 |
F7 NE APARTMENT | 25-DEC-04:00 | 3985.19 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 15.02 | 0.00 | -1397.68 | 0.00 | -3022.37 | 0.00 |
F7 N1 APARTMENT | 23-FEB-11:40 | 2526.08 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 248.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2901.59 | -345.71 |
F7 N2 APARTMENT | 23-FEB-11:40 | 2524.99 | 0.00 | 0.00 | 0.00 | 47.38 | 12.97 | 412.03 | 248.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2901.64 | -343.84 |
F7 S1 APARTMENT | 25-DEC-05:00 | 2118.08 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 96.38 | 0.00 | -857.78 | 0.00 | -1789.49 | 0.00 |
F7 S2 APARTMENT | 25-DEC-05:00 | 2120.02 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 94.39 | 0.00 | -857.72 | 0.00 | -1789.49 | 0.00 |
F8 SW APARTMENT | 25-DEC-04:00 | 4057.15 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 92.02 | 0.00 | -1398.27 | 0.00 | -3170.73 | 0.00 |
F8 NW APARTMENT | 13-FEB-10:53 | 4216.67 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -490.54 | 0.00 | -3636.19 | -556.47 |
F8 SE APARTMENT | 25-DEC-04:00 | 4060.86 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 70.20 | 0.00 | -1380.16 | 0.00 | -3170.73 | 0.00 |
F8 NE APARTMENT | 25-DEC-04:00 | 4153.69 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1402.01 | 0.00 | -3170.73 | -0.78 |
F8 N1 APARTMENT | 23-FEB-11:35 | 2676.01 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 248.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3037.54 | -359.06 |
F8 N2 APARTMENT | 23-FEB-11:35 | 2665.79 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 247.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3037.52 | -348.31 |
F8 S1 APARTMENT | 25-DEC-04:00 | 2233.29 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 103.15 | 0.00 | -843.77 | 0.00 | -1912.50 | 0.00 |
F8 S2 APARTMENT | 25-DEC-04:00 | 2235.29 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 101.09 | 0.00 | -843.71 | 0.00 | -1912.50 | 0.00 |
F9 SW APARTMENT | 25-DEC-05:00 | 4304.30 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1424.73 | 0.00 | -3245.85 | -66.52 |
F9 NW APARTMENT | 13-FEB-10:53 | 4479.50 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 406.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -491.82 | 0.00 | -3792.67 | -661.54 |
F9 SE APARTMENT | 25-DEC-04:00 | 4304.51 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1380.36 | 0.00 | -3306.74 | -37.23 |
F9 NE APARTMENT | 25-DEC-04:00 | 4385.63 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1403.15 | 0.00 | -3306.74 | -95.57 |
F9 N1 APARTMENT | 23-FEB-11:35 | 2841.76 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 248.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3164.00 | -398.90 |
F9 N2 APARTMENT | 23-FEB-11:35 | 2827.89 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 248.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3164.00 | -384.43 |
F9 S1 APARTMENT | 25-DEC-05:00 | 2425.49 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -859.28 | 0.00 | -1957.81 | -41.20 |
F9 S2 APARTMENT | 25-DEC-05:00 | 2427.09 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -859.24 | 0.00 | -1957.81 | -42.84 |
T SW APARTMENT | 25-DEC-05:00 | 5123.23 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1394.47 | 0.00 | -3369.24 | -792.32 |
T NW APARTMENT | 25-DEC-05:00 | 5175.87 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1416.62 | 0.00 | -3369.24 | -822.81 |
T SE APARTMENT | 25-DEC-05:00 | 5112.95 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1376.81 | 0.00 | -3369.24 | -799.70 |
T NE APARTMENT | 25-DEC-05:00 | 5163.86 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1399.10 | 0.00 | -3369.24 | -828.31 |
T N1 APARTMENT | 25-DEC-05:00 | 3263.05 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -864.27 | 0.00 | -2032.32 | -799.27 |
T N2 APARTMENT | 25-DEC-05:00 | 3263.08 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -864.27 | 0.00 | -2032.32 | -799.30 |
T S1 APARTMENT | 25-DEC-05:00 | 3200.46 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -842.07 | 0.00 | -2032.32 | -758.87 |
T S2 APARTMENT | 25-DEC-05:00 | 3200.85 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -842.06 | 0.00 | -2032.32 | -759.28 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 25-DEC-05:00 | 227765.61 | 0.00 | 0.00 | 0.00 | 14983.98 | 7740.61 | 17974.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -92080.73 | 0.00 | -169631.28 | -6752.72 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Sec1.1A-General InformationData | |
Weather File | Baltimore Blt Washngtn IntL MD USA TMY3 WMO#=724060 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 7836.48 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.50 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F2 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F3 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F4 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F6 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F7 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F8 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F9 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 7836.48 | 7059.89 | 776.58 |
Data | |
Number of hours heating loads not met | 114.00 |
Number of hours cooling loads not met | 71.00 |
Number of hours not met | 185.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 296.56 | 14401.37 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 162.88 | 10364.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 199.37 | 0.00 | 707.16 | 287479.30 | 0.00 | 0.00 |
Space Cooling | 491.20 | 81177.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 72.83 | 2374.85 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 23.01 | 3478.45 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 640.55 | 20311.59 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 0.00 | 0.00 | 1105.82 | 78213.16 | 0.00 | 0.00 |
Receptacle Equipment | 1137.32 | 51749.96 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 3059.89 | 1812.97 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 1137.32 | 3059.89 |
Natural Gas | 0.00 | 1812.97 |
Additional | 0.00 | 0.00 |
Total | 1137.32 | 4872.86 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 37.84 |
Space Heating | 25.44 |
Space Cooling | 62.68 |
Fans-Interior | 81.74 |
Service Water Heating | 0.00 |
Receptacle Equipment | 145.13 |
Miscellaneous | 37.63 |
Subtotal | 390.47 |
Natural Gas [MJ/m2] | |
Space Heating | 90.24 |
Service Water Heating | 141.11 |
Miscellaneous | 0.00 |
Subtotal | 231.35 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 6.09 |
Space Heating | 18.60 |
Space Cooling | 10.08 |
Fans-Interior | 13.15 |
Service Water Heating | 22.69 |
Receptacle Equipment | 23.34 |
Miscellaneous | 6.05 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.219224 |
G NW APARTMENT DIRECT AIR | 0.205733 |
OFFICE DIRECT AIR | 0.328933 |
G NE APARTMENT DIRECT AIR | 0.157840 |
G N1 APARTMENT DIRECT AIR | 0.108913 |
G N2 APARTMENT DIRECT AIR | 0.107468 |
G S1 APARTMENT DIRECT AIR | 0.132272 |
G S2 APARTMENT DIRECT AIR | 0.138280 |
F2 SW APARTMENT DIRECT AIR | 0.283753 |
F2 NW APARTMENT DIRECT AIR | 0.265630 |
F2 SE APARTMENT DIRECT AIR | 0.272261 |
F2 NE APARTMENT DIRECT AIR | 0.210927 |
F2 N1 APARTMENT DIRECT AIR | 0.146132 |
F2 N2 APARTMENT DIRECT AIR | 0.144947 |
F2 S1 APARTMENT DIRECT AIR | 0.175773 |
F2 S2 APARTMENT DIRECT AIR | 0.177892 |
F3 SW APARTMENT DIRECT AIR | 0.286896 |
F3 NW APARTMENT DIRECT AIR | 0.269321 |
F3 SE APARTMENT DIRECT AIR | 0.256140 |
F3 NE APARTMENT DIRECT AIR | 0.215555 |
F3 N1 APARTMENT DIRECT AIR | 0.150198 |
F3 N2 APARTMENT DIRECT AIR | 0.149024 |
F3 S1 APARTMENT DIRECT AIR | 0.179923 |
F3 S2 APARTMENT DIRECT AIR | 0.180850 |
F4 SW APARTMENT DIRECT AIR | 0.289542 |
F4 NW APARTMENT DIRECT AIR | 0.271927 |
F4 SE APARTMENT DIRECT AIR | 0.257148 |
F4 NE APARTMENT DIRECT AIR | 0.217868 |
F4 N1 APARTMENT DIRECT AIR | 0.152434 |
F4 N2 APARTMENT DIRECT AIR | 0.151266 |
F4 S1 APARTMENT DIRECT AIR | 0.182107 |
F4 S2 APARTMENT DIRECT AIR | 0.182862 |
M SW APARTMENT DIRECT AIR | 0.293728 |
M NW APARTMENT DIRECT AIR | 0.276114 |
M SE APARTMENT DIRECT AIR | 0.261354 |
M NE APARTMENT DIRECT AIR | 0.221792 |
M N1 APARTMENT DIRECT AIR | 0.156153 |
M N2 APARTMENT DIRECT AIR | 0.154989 |
M S1 APARTMENT DIRECT AIR | 0.185785 |
M S2 APARTMENT DIRECT AIR | 0.186515 |
F6 SW APARTMENT DIRECT AIR | 0.292112 |
F6 NW APARTMENT DIRECT AIR | 0.274417 |
F6 SE APARTMENT DIRECT AIR | 0.259986 |
F6 NE APARTMENT DIRECT AIR | 0.219979 |
F6 N1 APARTMENT DIRECT AIR | 0.154271 |
F6 N2 APARTMENT DIRECT AIR | 0.153116 |
F6 S1 APARTMENT DIRECT AIR | 0.183863 |
F6 S2 APARTMENT DIRECT AIR | 0.184590 |
F7 SW APARTMENT DIRECT AIR | 0.292394 |
F7 NW APARTMENT DIRECT AIR | 0.274713 |
F7 SE APARTMENT DIRECT AIR | 0.260479 |
F7 NE APARTMENT DIRECT AIR | 0.220125 |
F7 N1 APARTMENT DIRECT AIR | 0.154294 |
F7 N2 APARTMENT DIRECT AIR | 0.153146 |
F7 S1 APARTMENT DIRECT AIR | 0.183825 |
F7 S2 APARTMENT DIRECT AIR | 0.184551 |
F8 SW APARTMENT DIRECT AIR | 0.293868 |
F8 NW APARTMENT DIRECT AIR | 0.276214 |
F8 SE APARTMENT DIRECT AIR | 0.262104 |
F8 NE APARTMENT DIRECT AIR | 0.221399 |
F8 N1 APARTMENT DIRECT AIR | 0.155546 |
F8 N2 APARTMENT DIRECT AIR | 0.154405 |
F8 S1 APARTMENT DIRECT AIR | 0.184963 |
F8 S2 APARTMENT DIRECT AIR | 0.185689 |
F9 SW APARTMENT DIRECT AIR | 0.304341 |
F9 NW APARTMENT DIRECT AIR | 0.286786 |
F9 SE APARTMENT DIRECT AIR | 0.270725 |
F9 NE APARTMENT DIRECT AIR | 0.226726 |
F9 N1 APARTMENT DIRECT AIR | 0.164652 |
F9 N2 APARTMENT DIRECT AIR | 0.163497 |
F9 S1 APARTMENT DIRECT AIR | 0.192123 |
F9 S2 APARTMENT DIRECT AIR | 0.192824 |
T SW APARTMENT DIRECT AIR | 0.375718 |
T NW APARTMENT DIRECT AIR | 0.350598 |
T SE APARTMENT DIRECT AIR | 0.338189 |
T NE APARTMENT DIRECT AIR | 0.282672 |
T N1 APARTMENT DIRECT AIR | 0.214058 |
T N2 APARTMENT DIRECT AIR | 0.213784 |
T S1 APARTMENT DIRECT AIR | 0.267214 |
T S2 APARTMENT DIRECT AIR | 0.267903 |
Maximum Flow Rate [m3/s] | |
AIRLOOP G SW MAIN BRANCH | 0.219224 |
AIRLOOP G NW MAIN BRANCH | 0.205733 |
AIRLOOP OFFICE MAIN BRANCH | 0.328933 |
AIRLOOP G NE MAIN BRANCH | 0.157840 |
AIRLOOP G N1 MAIN BRANCH | 0.108913 |
AIRLOOP G N2 MAIN BRANCH | 0.107468 |
AIRLOOP G S1 MAIN BRANCH | 0.132272 |
AIRLOOP G S2 MAIN BRANCH | 0.138280 |
AIRLOOP F2 SW MAIN BRANCH | 0.283753 |
AIRLOOP F2 NW MAIN BRANCH | 0.265630 |
AIRLOOP F2 SE MAIN BRANCH | 0.272261 |
AIRLOOP F2 NE MAIN BRANCH | 0.210927 |
AIRLOOP F2 N1 MAIN BRANCH | 0.146132 |
AIRLOOP F2 N2 MAIN BRANCH | 0.144947 |
AIRLOOP F2 S1 MAIN BRANCH | 0.175773 |
AIRLOOP F2 S2 MAIN BRANCH | 0.177892 |
AIRLOOP F3 SW MAIN BRANCH | 0.286896 |
AIRLOOP F3 NW MAIN BRANCH | 0.269321 |
AIRLOOP F3 SE MAIN BRANCH | 0.256140 |
AIRLOOP F3 NE MAIN BRANCH | 0.215555 |
AIRLOOP F3 N1 MAIN BRANCH | 0.150198 |
AIRLOOP F3 N2 MAIN BRANCH | 0.149024 |
AIRLOOP F3 S1 MAIN BRANCH | 0.179923 |
AIRLOOP F3 S2 MAIN BRANCH | 0.180850 |
AIRLOOP F4 SW MAIN BRANCH | 0.289542 |
AIRLOOP F4 NW MAIN BRANCH | 0.271927 |
AIRLOOP F4 SE MAIN BRANCH | 0.257148 |
AIRLOOP F4 NE MAIN BRANCH | 0.217868 |
AIRLOOP F4 N1 MAIN BRANCH | 0.152434 |
AIRLOOP F4 N2 MAIN BRANCH | 0.151266 |
AIRLOOP F4 S1 MAIN BRANCH | 0.182107 |
AIRLOOP F4 S2 MAIN BRANCH | 0.182862 |
AIRLOOP M SW MAIN BRANCH | 0.293728 |
AIRLOOP M NW MAIN BRANCH | 0.276114 |
AIRLOOP M SE MAIN BRANCH | 0.261354 |
AIRLOOP M NE MAIN BRANCH | 0.221792 |
AIRLOOP M N1 MAIN BRANCH | 0.156153 |
AIRLOOP M N2 MAIN BRANCH | 0.154989 |
AIRLOOP M S1 MAIN BRANCH | 0.185785 |
AIRLOOP M S2 MAIN BRANCH | 0.186515 |
AIRLOOP F6 SW MAIN BRANCH | 0.292112 |
AIRLOOP F6 NW MAIN BRANCH | 0.274417 |
AIRLOOP F6 SE MAIN BRANCH | 0.259986 |
AIRLOOP F6 NE MAIN BRANCH | 0.219979 |
AIRLOOP F6 N1 MAIN BRANCH | 0.154271 |
AIRLOOP F6 N2 MAIN BRANCH | 0.153116 |
AIRLOOP F6 S1 MAIN BRANCH | 0.183863 |
AIRLOOP F6 S2 MAIN BRANCH | 0.184590 |
AIRLOOP F7 SW MAIN BRANCH | 0.292394 |
AIRLOOP F7 NW MAIN BRANCH | 0.274713 |
AIRLOOP F7 SE MAIN BRANCH | 0.260479 |
AIRLOOP F7 NE MAIN BRANCH | 0.220125 |
AIRLOOP F7 N1 MAIN BRANCH | 0.154294 |
AIRLOOP F7 N2 MAIN BRANCH | 0.153146 |
AIRLOOP F7 S1 MAIN BRANCH | 0.183825 |
AIRLOOP F7 S2 MAIN BRANCH | 0.184551 |
AIRLOOP F8 SW MAIN BRANCH | 0.293868 |
AIRLOOP F8 NW MAIN BRANCH | 0.276214 |
AIRLOOP F8 SE MAIN BRANCH | 0.262104 |
AIRLOOP F8 NE MAIN BRANCH | 0.221399 |
AIRLOOP F8 N1 MAIN BRANCH | 0.155546 |
AIRLOOP F8 N2 MAIN BRANCH | 0.154405 |
AIRLOOP F8 S1 MAIN BRANCH | 0.184963 |
AIRLOOP F8 S2 MAIN BRANCH | 0.185689 |
AIRLOOP F9 SW MAIN BRANCH | 0.304341 |
AIRLOOP F9 NW MAIN BRANCH | 0.286786 |
AIRLOOP F9 SE MAIN BRANCH | 0.270725 |
AIRLOOP F9 NE MAIN BRANCH | 0.226726 |
AIRLOOP F9 N1 MAIN BRANCH | 0.164652 |
AIRLOOP F9 N2 MAIN BRANCH | 0.163497 |
AIRLOOP F9 S1 MAIN BRANCH | 0.192123 |
AIRLOOP F9 S2 MAIN BRANCH | 0.192824 |
AIRLOOP T SW MAIN BRANCH | 0.375718 |
AIRLOOP T NW MAIN BRANCH | 0.350598 |
AIRLOOP T SE MAIN BRANCH | 0.338189 |
AIRLOOP T NE MAIN BRANCH | 0.282672 |
AIRLOOP T N1 MAIN BRANCH | 0.214058 |
AIRLOOP T N2 MAIN BRANCH | 0.213784 |
AIRLOOP T S1 MAIN BRANCH | 0.267214 |
AIRLOOP T S2 MAIN BRANCH | 0.267903 |
Design Supply Air Flow Rate [m3/s] | |
AIRLOOP G SW | 0.219224 |
AIRLOOP G NW | 0.205733 |
AIRLOOP OFFICE | 0.328933 |
AIRLOOP G NE | 0.157840 |
AIRLOOP G N1 | 0.108913 |
AIRLOOP G N2 | 0.107468 |
AIRLOOP G S1 | 0.132272 |
AIRLOOP G S2 | 0.138280 |
AIRLOOP F2 SW | 0.283753 |
AIRLOOP F2 NW | 0.265630 |
AIRLOOP F2 SE | 0.272261 |
AIRLOOP F2 NE | 0.210927 |
AIRLOOP F2 N1 | 0.146132 |
AIRLOOP F2 N2 | 0.144947 |
AIRLOOP F2 S1 | 0.175773 |
AIRLOOP F2 S2 | 0.177892 |
AIRLOOP F3 SW | 0.286896 |
AIRLOOP F3 NW | 0.269321 |
AIRLOOP F3 SE | 0.256140 |
AIRLOOP F3 NE | 0.215555 |
AIRLOOP F3 N1 | 0.150198 |
AIRLOOP F3 N2 | 0.149024 |
AIRLOOP F3 S1 | 0.179923 |
AIRLOOP F3 S2 | 0.180850 |
AIRLOOP F4 SW | 0.289542 |
AIRLOOP F4 NW | 0.271927 |
AIRLOOP F4 SE | 0.257148 |
AIRLOOP F4 NE | 0.217868 |
AIRLOOP F4 N1 | 0.152434 |
AIRLOOP F4 N2 | 0.151266 |
AIRLOOP F4 S1 | 0.182107 |
AIRLOOP F4 S2 | 0.182862 |
AIRLOOP M SW | 0.293728 |
AIRLOOP M NW | 0.276114 |
AIRLOOP M SE | 0.261354 |
AIRLOOP M NE | 0.221792 |
AIRLOOP M N1 | 0.156153 |
AIRLOOP M N2 | 0.154989 |
AIRLOOP M S1 | 0.185785 |
AIRLOOP M S2 | 0.186515 |
AIRLOOP F6 SW | 0.292112 |
AIRLOOP F6 NW | 0.274417 |
AIRLOOP F6 SE | 0.259986 |
AIRLOOP F6 NE | 0.219979 |
AIRLOOP F6 N1 | 0.154271 |
AIRLOOP F6 N2 | 0.153116 |
AIRLOOP F6 S1 | 0.183863 |
AIRLOOP F6 S2 | 0.184590 |
AIRLOOP F7 SW | 0.292394 |
AIRLOOP F7 NW | 0.274713 |
AIRLOOP F7 SE | 0.260479 |
AIRLOOP F7 NE | 0.220125 |
AIRLOOP F7 N1 | 0.154294 |
AIRLOOP F7 N2 | 0.153146 |
AIRLOOP F7 S1 | 0.183825 |
AIRLOOP F7 S2 | 0.184551 |
AIRLOOP F8 SW | 0.293868 |
AIRLOOP F8 NW | 0.276214 |
AIRLOOP F8 SE | 0.262104 |
AIRLOOP F8 NE | 0.221399 |
AIRLOOP F8 N1 | 0.155546 |
AIRLOOP F8 N2 | 0.154405 |
AIRLOOP F8 S1 | 0.184963 |
AIRLOOP F8 S2 | 0.185689 |
AIRLOOP F9 SW | 0.304341 |
AIRLOOP F9 NW | 0.286786 |
AIRLOOP F9 SE | 0.270725 |
AIRLOOP F9 NE | 0.226726 |
AIRLOOP F9 N1 | 0.164652 |
AIRLOOP F9 N2 | 0.163497 |
AIRLOOP F9 S1 | 0.192123 |
AIRLOOP F9 S2 | 0.192824 |
AIRLOOP T SW | 0.375718 |
AIRLOOP T NW | 0.350598 |
AIRLOOP T SE | 0.338189 |
AIRLOOP T NE | 0.282672 |
AIRLOOP T N1 | 0.214058 |
AIRLOOP T N2 | 0.213784 |
AIRLOOP T S1 | 0.267214 |
AIRLOOP T S2 | 0.267903 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
AIRLOOP G SW OA CONTROLLER | 0.219224 | 0.025952 |
AIRLOOP G NW OA CONTROLLER | 0.205733 | 0.025952 |
AIRLOOP OFFICE OA CONTROLLER | 0.328933 | 0.038103 |
AIRLOOP G NE OA CONTROLLER | 0.157840 | 0.025952 |
AIRLOOP G N1 OA CONTROLLER | 0.108913 | 0.025952 |
AIRLOOP G N2 OA CONTROLLER | 0.107468 | 0.025952 |
AIRLOOP G S1 OA CONTROLLER | 0.132272 | 0.025952 |
AIRLOOP G S2 OA CONTROLLER | 0.138280 | 0.025952 |
AIRLOOP F2 SW OA CONTROLLER | 0.283753 | 0.025952 |
AIRLOOP F2 NW OA CONTROLLER | 0.265630 | 0.025952 |
AIRLOOP F2 SE OA CONTROLLER | 0.272261 | 0.025952 |
AIRLOOP F2 NE OA CONTROLLER | 0.210927 | 0.025952 |
AIRLOOP F2 N1 OA CONTROLLER | 0.146132 | 0.025952 |
AIRLOOP F2 N2 OA CONTROLLER | 0.144947 | 0.025952 |
AIRLOOP F2 S1 OA CONTROLLER | 0.175773 | 0.025952 |
AIRLOOP F2 S2 OA CONTROLLER | 0.177892 | 0.025952 |
AIRLOOP F3 SW OA CONTROLLER | 0.286896 | 0.025952 |
AIRLOOP F3 NW OA CONTROLLER | 0.269321 | 0.025952 |
AIRLOOP F3 SE OA CONTROLLER | 0.256140 | 0.025952 |
AIRLOOP F3 NE OA CONTROLLER | 0.215555 | 0.025952 |
AIRLOOP F3 N1 OA CONTROLLER | 0.150198 | 0.025952 |
AIRLOOP F3 N2 OA CONTROLLER | 0.149024 | 0.025952 |
AIRLOOP F3 S1 OA CONTROLLER | 0.179923 | 0.025952 |
AIRLOOP F3 S2 OA CONTROLLER | 0.180850 | 0.025952 |
AIRLOOP F4 SW OA CONTROLLER | 0.289542 | 0.025952 |
AIRLOOP F4 NW OA CONTROLLER | 0.271927 | 0.025952 |
AIRLOOP F4 SE OA CONTROLLER | 0.257148 | 0.025952 |
AIRLOOP F4 NE OA CONTROLLER | 0.217868 | 0.025952 |
AIRLOOP F4 N1 OA CONTROLLER | 0.152434 | 0.025952 |
AIRLOOP F4 N2 OA CONTROLLER | 0.151266 | 0.025952 |
AIRLOOP F4 S1 OA CONTROLLER | 0.182107 | 0.025952 |
AIRLOOP F4 S2 OA CONTROLLER | 0.182862 | 0.025952 |
AIRLOOP M SW OA CONTROLLER | 0.293728 | 0.025952 |
AIRLOOP M NW OA CONTROLLER | 0.276114 | 0.025952 |
AIRLOOP M SE OA CONTROLLER | 0.261354 | 0.025952 |
AIRLOOP M NE OA CONTROLLER | 0.221792 | 0.025952 |
AIRLOOP M N1 OA CONTROLLER | 0.156153 | 0.025952 |
AIRLOOP M N2 OA CONTROLLER | 0.154989 | 0.025952 |
AIRLOOP M S1 OA CONTROLLER | 0.185785 | 0.025952 |
AIRLOOP M S2 OA CONTROLLER | 0.186515 | 0.025952 |
AIRLOOP F6 SW OA CONTROLLER | 0.292112 | 0.025952 |
AIRLOOP F6 NW OA CONTROLLER | 0.274417 | 0.025952 |
AIRLOOP F6 SE OA CONTROLLER | 0.259986 | 0.025952 |
AIRLOOP F6 NE OA CONTROLLER | 0.219979 | 0.025952 |
AIRLOOP F6 N1 OA CONTROLLER | 0.154271 | 0.025952 |
AIRLOOP F6 N2 OA CONTROLLER | 0.153116 | 0.025952 |
AIRLOOP F6 S1 OA CONTROLLER | 0.183863 | 0.025952 |
AIRLOOP F6 S2 OA CONTROLLER | 0.184590 | 0.025952 |
AIRLOOP F7 SW OA CONTROLLER | 0.292394 | 0.025952 |
AIRLOOP F7 NW OA CONTROLLER | 0.274713 | 0.025952 |
AIRLOOP F7 SE OA CONTROLLER | 0.260479 | 0.025952 |
AIRLOOP F7 NE OA CONTROLLER | 0.220125 | 0.025952 |
AIRLOOP F7 N1 OA CONTROLLER | 0.154294 | 0.025952 |
AIRLOOP F7 N2 OA CONTROLLER | 0.153146 | 0.025952 |
AIRLOOP F7 S1 OA CONTROLLER | 0.183825 | 0.025952 |
AIRLOOP F7 S2 OA CONTROLLER | 0.184551 | 0.025952 |
AIRLOOP F8 SW OA CONTROLLER | 0.293868 | 0.025952 |
AIRLOOP F8 NW OA CONTROLLER | 0.276214 | 0.025952 |
AIRLOOP F8 SE OA CONTROLLER | 0.262104 | 0.025952 |
AIRLOOP F8 NE OA CONTROLLER | 0.221399 | 0.025952 |
AIRLOOP F8 N1 OA CONTROLLER | 0.155546 | 0.025952 |
AIRLOOP F8 N2 OA CONTROLLER | 0.154405 | 0.025952 |
AIRLOOP F8 S1 OA CONTROLLER | 0.184963 | 0.025952 |
AIRLOOP F8 S2 OA CONTROLLER | 0.185689 | 0.025952 |
AIRLOOP F9 SW OA CONTROLLER | 0.304341 | 0.025952 |
AIRLOOP F9 NW OA CONTROLLER | 0.286786 | 0.025952 |
AIRLOOP F9 SE OA CONTROLLER | 0.270725 | 0.025952 |
AIRLOOP F9 NE OA CONTROLLER | 0.226726 | 0.025952 |
AIRLOOP F9 N1 OA CONTROLLER | 0.164652 | 0.025952 |
AIRLOOP F9 N2 OA CONTROLLER | 0.163497 | 0.025952 |
AIRLOOP F9 S1 OA CONTROLLER | 0.192123 | 0.025952 |
AIRLOOP F9 S2 OA CONTROLLER | 0.192824 | 0.025952 |
AIRLOOP T SW OA CONTROLLER | 0.375718 | 0.025952 |
AIRLOOP T NW OA CONTROLLER | 0.350598 | 0.025952 |
AIRLOOP T SE OA CONTROLLER | 0.338189 | 0.025952 |
AIRLOOP T NE OA CONTROLLER | 0.282672 | 0.025952 |
AIRLOOP T N1 OA CONTROLLER | 0.214058 | 0.025952 |
AIRLOOP T N2 OA CONTROLLER | 0.213784 | 0.025952 |
AIRLOOP T S1 OA CONTROLLER | 0.267214 | 0.025952 |
AIRLOOP T S2 OA CONTROLLER | 0.267903 | 0.025952 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity [W] | Rated Sensible Cooling Capacity [W] | Rated Water Flow Rate [m3/s] | |
HEAT PUMP COOLING MODE AIRLOOP G SW | 0.219224 | 4068.34 | 2728.95 | 0.000089 |
HEAT PUMP COOLING MODE AIRLOOP G NW | 0.205733 | 3852.75 | 2569.40 | 0.000084 |
HEAT PUMP COOLING MODE AIRLOOP OFFICE | 0.328933 | 5969.90 | 4056.24 | 0.000130 |
HEAT PUMP COOLING MODE AIRLOOP G NE | 0.157840 | 3125.32 | 2030.66 | 0.000068 |
HEAT PUMP COOLING MODE AIRLOOP G N1 | 0.108913 | 2341.16 | 1471.97 | 0.000051 |
HEAT PUMP COOLING MODE AIRLOOP G N2 | 0.107468 | 2319.26 | 1455.98 | 0.000051 |
HEAT PUMP COOLING MODE AIRLOOP G S1 | 0.132272 | 2748.20 | 1758.43 | 0.000060 |
HEAT PUMP COOLING MODE AIRLOOP G S2 | 0.138280 | 2835.58 | 1824.39 | 0.000062 |
HEAT PUMP COOLING MODE AIRLOOP F2 SW | 0.283753 | 5089.12 | 3463.86 | 0.000111 |
HEAT PUMP COOLING MODE AIRLOOP F2 NW | 0.265630 | 4813.92 | 3256.22 | 0.000105 |
HEAT PUMP COOLING MODE AIRLOOP F2 SE | 0.272261 | 4949.47 | 3350.54 | 0.000108 |
HEAT PUMP COOLING MODE AIRLOOP F2 NE | 0.210927 | 3988.74 | 2642.01 | 0.000087 |
HEAT PUMP COOLING MODE AIRLOOP F2 N1 | 0.146132 | 2943.25 | 1898.46 | 0.000064 |
HEAT PUMP COOLING MODE AIRLOOP F2 N2 | 0.144947 | 2925.58 | 1885.38 | 0.000064 |
HEAT PUMP COOLING MODE AIRLOOP F2 S1 | 0.175773 | 3436.13 | 2254.66 | 0.000075 |
HEAT PUMP COOLING MODE AIRLOOP F2 S2 | 0.177892 | 3466.69 | 2277.87 | 0.000076 |
HEAT PUMP COOLING MODE AIRLOOP F3 SW | 0.286896 | 5194.08 | 3516.94 | 0.000113 |
HEAT PUMP COOLING MODE AIRLOOP F3 NW | 0.269321 | 4925.64 | 3315.14 | 0.000108 |
HEAT PUMP COOLING MODE AIRLOOP F3 SE | 0.256140 | 4775.27 | 3192.31 | 0.000104 |
HEAT PUMP COOLING MODE AIRLOOP F3 NE | 0.215555 | 4110.79 | 2710.71 | 0.000090 |
HEAT PUMP COOLING MODE AIRLOOP F3 N1 | 0.150198 | 3034.20 | 1953.78 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP F3 N2 | 0.149024 | 3016.63 | 1940.81 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP F3 S1 | 0.179923 | 3529.69 | 2311.17 | 0.000077 |
HEAT PUMP COOLING MODE AIRLOOP F3 S2 | 0.180850 | 3543.01 | 2321.29 | 0.000077 |
HEAT PUMP COOLING MODE AIRLOOP F4 SW | 0.289542 | 5282.11 | 3562.61 | 0.000115 |
HEAT PUMP COOLING MODE AIRLOOP F4 NW | 0.271927 | 5006.65 | 3357.52 | 0.000109 |
HEAT PUMP COOLING MODE AIRLOOP F4 SE | 0.257148 | 4832.38 | 3217.03 | 0.000106 |
HEAT PUMP COOLING MODE AIRLOOP F4 NE | 0.217868 | 4184.98 | 2749.49 | 0.000091 |
HEAT PUMP COOLING MODE AIRLOOP F4 N1 | 0.152434 | 3090.28 | 1986.31 | 0.000068 |
HEAT PUMP COOLING MODE AIRLOOP F4 N2 | 0.151266 | 3072.72 | 1973.39 | 0.000067 |
HEAT PUMP COOLING MODE AIRLOOP F4 S1 | 0.182107 | 3586.35 | 2343.37 | 0.000078 |
HEAT PUMP COOLING MODE AIRLOOP F4 S2 | 0.182862 | 3597.21 | 2351.61 | 0.000079 |
HEAT PUMP COOLING MODE AIRLOOP M SW | 0.293728 | 5378.50 | 3619.86 | 0.000117 |
HEAT PUMP COOLING MODE AIRLOOP M NW | 0.276114 | 5102.44 | 3414.67 | 0.000111 |
HEAT PUMP COOLING MODE AIRLOOP M SE | 0.261354 | 4927.95 | 3274.32 | 0.000108 |
HEAT PUMP COOLING MODE AIRLOOP M NE | 0.221792 | 4283.46 | 2807.83 | 0.000094 |
HEAT PUMP COOLING MODE AIRLOOP M N1 | 0.156153 | 3164.21 | 2033.72 | 0.000069 |
HEAT PUMP COOLING MODE AIRLOOP M N2 | 0.154989 | 3146.69 | 2020.84 | 0.000069 |
HEAT PUMP COOLING MODE AIRLOOP M S1 | 0.185785 | 3660.25 | 2390.49 | 0.000080 |
HEAT PUMP COOLING MODE AIRLOOP M S2 | 0.186515 | 3670.77 | 2398.47 | 0.000080 |
HEAT PUMP COOLING MODE AIRLOOP F6 SW | 0.292112 | 5385.45 | 3611.82 | 0.000118 |
HEAT PUMP COOLING MODE AIRLOOP F6 NW | 0.274417 | 5111.59 | 3408.15 | 0.000112 |
HEAT PUMP COOLING MODE AIRLOOP F6 SE | 0.259986 | 4936.97 | 3268.72 | 0.000108 |
HEAT PUMP COOLING MODE AIRLOOP F6 NE | 0.219979 | 4283.98 | 2797.08 | 0.000094 |
HEAT PUMP COOLING MODE AIRLOOP F6 N1 | 0.154271 | 3151.76 | 2018.46 | 0.000069 |
HEAT PUMP COOLING MODE AIRLOOP F6 N2 | 0.153116 | 3134.29 | 2005.67 | 0.000068 |
HEAT PUMP COOLING MODE AIRLOOP F6 S1 | 0.183863 | 3649.20 | 2375.05 | 0.000080 |
HEAT PUMP COOLING MODE AIRLOOP F6 S2 | 0.184590 | 3659.69 | 2382.99 | 0.000080 |
HEAT PUMP COOLING MODE AIRLOOP F7 SW | 0.292394 | 5415.98 | 3623.38 | 0.000118 |
HEAT PUMP COOLING MODE AIRLOOP F7 NW | 0.274713 | 5141.65 | 3419.76 | 0.000112 |
HEAT PUMP COOLING MODE AIRLOOP F7 SE | 0.260479 | 4969.42 | 3282.41 | 0.000109 |
HEAT PUMP COOLING MODE AIRLOOP F7 NE | 0.220125 | 4309.83 | 2806.73 | 0.000094 |
HEAT PUMP COOLING MODE AIRLOOP F7 N1 | 0.154294 | 3165.69 | 2023.50 | 0.000069 |
HEAT PUMP COOLING MODE AIRLOOP F7 N2 | 0.153146 | 3148.25 | 2010.77 | 0.000069 |
HEAT PUMP COOLING MODE AIRLOOP F7 S1 | 0.183825 | 3663.51 | 2379.61 | 0.000080 |
HEAT PUMP COOLING MODE AIRLOOP F7 S2 | 0.184551 | 3674.01 | 2387.55 | 0.000080 |
HEAT PUMP COOLING MODE AIRLOOP F8 SW | 0.293868 | 5461.03 | 3647.16 | 0.000119 |
HEAT PUMP COOLING MODE AIRLOOP F8 NW | 0.276214 | 5186.55 | 3443.73 | 0.000113 |
HEAT PUMP COOLING MODE AIRLOOP F8 SE | 0.262104 | 5018.59 | 3309.14 | 0.000110 |
HEAT PUMP COOLING MODE AIRLOOP F8 NE | 0.221399 | 4349.83 | 2827.95 | 0.000095 |
HEAT PUMP COOLING MODE AIRLOOP F8 N1 | 0.155546 | 3196.64 | 2041.61 | 0.000070 |
HEAT PUMP COOLING MODE AIRLOOP F8 N2 | 0.154405 | 3179.28 | 2028.95 | 0.000069 |
HEAT PUMP COOLING MODE AIRLOOP F8 S1 | 0.184963 | 3693.53 | 2396.61 | 0.000081 |
HEAT PUMP COOLING MODE AIRLOOP F8 S2 | 0.185689 | 3704.06 | 2404.55 | 0.000081 |
HEAT PUMP COOLING MODE AIRLOOP F9 SW | 0.304341 | 5635.34 | 3769.15 | 0.000123 |
HEAT PUMP COOLING MODE AIRLOOP F9 NW | 0.286786 | 5362.55 | 3566.82 | 0.000117 |
HEAT PUMP COOLING MODE AIRLOOP F9 SE | 0.270725 | 5166.14 | 3410.89 | 0.000113 |
HEAT PUMP COOLING MODE AIRLOOP F9 NE | 0.226726 | 4448.79 | 2893.36 | 0.000097 |
HEAT PUMP COOLING MODE AIRLOOP F9 N1 | 0.164652 | 3344.92 | 2146.15 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F9 N2 | 0.163497 | 3327.41 | 2133.34 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F9 S1 | 0.192123 | 3813.81 | 2480.89 | 0.000083 |
HEAT PUMP COOLING MODE AIRLOOP F9 S2 | 0.192824 | 3823.95 | 2488.56 | 0.000084 |
HEAT PUMP COOLING MODE AIRLOOP T SW | 0.375718 | 6706.89 | 4567.38 | 0.000147 |
HEAT PUMP COOLING MODE AIRLOOP T NW | 0.350598 | 6326.19 | 4282.86 | 0.000138 |
HEAT PUMP COOLING MODE AIRLOOP T SE | 0.338189 | 6166.78 | 4156.87 | 0.000135 |
HEAT PUMP COOLING MODE AIRLOOP T NE | 0.282672 | 5304.64 | 3520.49 | 0.000116 |
HEAT PUMP COOLING MODE AIRLOOP T N1 | 0.214058 | 4146.95 | 2726.04 | 0.000091 |
HEAT PUMP COOLING MODE AIRLOOP T N2 | 0.213784 | 4142.53 | 2722.90 | 0.000090 |
HEAT PUMP COOLING MODE AIRLOOP T S1 | 0.267214 | 4916.02 | 3308.15 | 0.000107 |
HEAT PUMP COOLING MODE AIRLOOP T S2 | 0.267903 | 4925.75 | 3315.64 | 0.000108 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Supplemental Heating Coil Nominal Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
AIRLOOP G SW DXAC HEAT PUMP | 0.219224 | 0.219224 | 0.219224 | 0.219224 | 4068.34 | 4068.34 | 3554.23 | 1.00 |
AIRLOOP G NW DXAC HEAT PUMP | 0.205733 | 0.205733 | 0.205733 | 0.205733 | 3852.75 | 3852.75 | 3556.67 | 1.00 |
AIRLOOP OFFICE DXAC HEAT PUMP | 0.328933 | 0.328933 | 0.328933 | 0.328933 | 5969.90 | 5969.90 | 4397.18 | 1.00 |
AIRLOOP G NE DXAC HEAT PUMP | 0.157840 | 0.157840 | 0.157840 | 0.157840 | 3125.32 | 3125.32 | 3559.11 | 1.00 |
AIRLOOP G N1 DXAC HEAT PUMP | 0.108913 | 0.108913 | 0.108913 | 0.108913 | 2341.16 | 2341.16 | 2688.13 | 1.00 |
AIRLOOP G N2 DXAC HEAT PUMP | 0.107468 | 0.107468 | 0.107468 | 0.107468 | 2319.26 | 2319.26 | 2688.18 | 1.00 |
AIRLOOP G S1 DXAC HEAT PUMP | 0.132272 | 0.132272 | 0.132272 | 0.132272 | 2748.20 | 2748.20 | 2682.34 | 1.00 |
AIRLOOP G S2 DXAC HEAT PUMP | 0.138280 | 0.138280 | 0.138280 | 0.138280 | 2835.58 | 2835.58 | 2688.67 | 1.00 |
AIRLOOP F2 SW DXAC HEAT PUMP | 0.283753 | 0.283753 | 0.283753 | 0.283753 | 5089.12 | 5089.12 | 3559.06 | 1.00 |
AIRLOOP F2 NW DXAC HEAT PUMP | 0.265630 | 0.265630 | 0.265630 | 0.265630 | 4813.92 | 4813.92 | 3558.84 | 1.00 |
AIRLOOP F2 SE DXAC HEAT PUMP | 0.272261 | 0.272261 | 0.272261 | 0.272261 | 4949.47 | 4949.47 | 3577.66 | 1.00 |
AIRLOOP F2 NE DXAC HEAT PUMP | 0.210927 | 0.210927 | 0.210927 | 0.210927 | 3988.74 | 3988.74 | 3558.96 | 1.00 |
AIRLOOP F2 N1 DXAC HEAT PUMP | 0.146132 | 0.146132 | 0.146132 | 0.146132 | 2943.25 | 2943.25 | 2466.31 | 1.00 |
AIRLOOP F2 N2 DXAC HEAT PUMP | 0.144947 | 0.144947 | 0.144947 | 0.144947 | 2925.58 | 2925.58 | 2466.32 | 1.00 |
AIRLOOP F2 S1 DXAC HEAT PUMP | 0.175773 | 0.175773 | 0.175773 | 0.175773 | 3436.13 | 3436.13 | 2469.33 | 1.00 |
AIRLOOP F2 S2 DXAC HEAT PUMP | 0.177892 | 0.177892 | 0.177892 | 0.177892 | 3466.69 | 3466.69 | 2470.53 | 1.00 |
AIRLOOP F3 SW DXAC HEAT PUMP | 0.286896 | 0.286896 | 0.286896 | 0.286896 | 5194.08 | 5194.08 | 3633.94 | 1.00 |
AIRLOOP F3 NW DXAC HEAT PUMP | 0.269321 | 0.269321 | 0.269321 | 0.269321 | 4925.64 | 4925.64 | 3637.88 | 1.00 |
AIRLOOP F3 SE DXAC HEAT PUMP | 0.256140 | 0.256140 | 0.256140 | 0.256140 | 4775.27 | 4775.27 | 3634.13 | 1.00 |
AIRLOOP F3 NE DXAC HEAT PUMP | 0.215555 | 0.215555 | 0.215555 | 0.215555 | 4110.79 | 4110.79 | 3636.07 | 1.00 |
AIRLOOP F3 N1 DXAC HEAT PUMP | 0.150198 | 0.150198 | 0.150198 | 0.150198 | 3034.20 | 3034.20 | 2473.05 | 1.00 |
AIRLOOP F3 N2 DXAC HEAT PUMP | 0.149024 | 0.149024 | 0.149024 | 0.149024 | 3016.63 | 3016.63 | 2473.00 | 1.00 |
AIRLOOP F3 S1 DXAC HEAT PUMP | 0.179923 | 0.179923 | 0.179923 | 0.179923 | 3529.69 | 3529.69 | 2469.93 | 1.00 |
AIRLOOP F3 S2 DXAC HEAT PUMP | 0.180850 | 0.180850 | 0.180850 | 0.180850 | 3543.01 | 3543.01 | 2470.07 | 1.00 |
AIRLOOP F4 SW DXAC HEAT PUMP | 0.289542 | 0.289542 | 0.289542 | 0.289542 | 5282.11 | 5282.11 | 3748.75 | 1.00 |
AIRLOOP F4 NW DXAC HEAT PUMP | 0.271927 | 0.271927 | 0.271927 | 0.271927 | 5006.65 | 5006.65 | 3755.50 | 1.00 |
AIRLOOP F4 SE DXAC HEAT PUMP | 0.257148 | 0.257148 | 0.257148 | 0.257148 | 4832.38 | 4832.38 | 3745.71 | 1.00 |
AIRLOOP F4 NE DXAC HEAT PUMP | 0.217868 | 0.217868 | 0.217868 | 0.217868 | 4184.98 | 4184.98 | 3752.25 | 1.00 |
AIRLOOP F4 N1 DXAC HEAT PUMP | 0.152434 | 0.152434 | 0.152434 | 0.152434 | 3090.28 | 3090.28 | 2533.53 | 1.00 |
AIRLOOP F4 N2 DXAC HEAT PUMP | 0.151266 | 0.151266 | 0.151266 | 0.151266 | 3072.72 | 3072.72 | 2533.45 | 1.00 |
AIRLOOP F4 S1 DXAC HEAT PUMP | 0.182107 | 0.182107 | 0.182107 | 0.182107 | 3586.35 | 3586.35 | 2527.29 | 1.00 |
AIRLOOP F4 S2 DXAC HEAT PUMP | 0.182862 | 0.182862 | 0.182862 | 0.182862 | 3597.21 | 3597.21 | 2527.23 | 1.00 |
AIRLOOP M SW DXAC HEAT PUMP | 0.293728 | 0.293728 | 0.293728 | 0.293728 | 5378.50 | 5378.50 | 3832.84 | 1.00 |
AIRLOOP M NW DXAC HEAT PUMP | 0.276114 | 0.276114 | 0.276114 | 0.276114 | 5102.44 | 5102.44 | 3840.48 | 1.00 |
AIRLOOP M SE DXAC HEAT PUMP | 0.261354 | 0.261354 | 0.261354 | 0.261354 | 4927.95 | 4927.95 | 3828.49 | 1.00 |
AIRLOOP M NE DXAC HEAT PUMP | 0.221792 | 0.221792 | 0.221792 | 0.221792 | 4283.46 | 4283.46 | 3836.10 | 1.00 |
AIRLOOP M N1 DXAC HEAT PUMP | 0.156153 | 0.156153 | 0.156153 | 0.156153 | 3164.21 | 3164.21 | 2573.04 | 1.00 |
AIRLOOP M N2 DXAC HEAT PUMP | 0.154989 | 0.154989 | 0.154989 | 0.154989 | 3146.69 | 3146.69 | 2572.93 | 1.00 |
AIRLOOP M S1 DXAC HEAT PUMP | 0.185785 | 0.185785 | 0.185785 | 0.185785 | 3660.25 | 3660.25 | 2565.80 | 1.00 |
AIRLOOP M S2 DXAC HEAT PUMP | 0.186515 | 0.186515 | 0.186515 | 0.186515 | 3670.77 | 3670.77 | 2565.70 | 1.00 |
AIRLOOP F6 SW DXAC HEAT PUMP | 0.292112 | 0.292112 | 0.292112 | 0.292112 | 5385.45 | 5385.45 | 3966.63 | 1.00 |
AIRLOOP F6 NW DXAC HEAT PUMP | 0.274417 | 0.274417 | 0.274417 | 0.274417 | 5111.59 | 5111.59 | 3976.66 | 1.00 |
AIRLOOP F6 SE DXAC HEAT PUMP | 0.259986 | 0.259986 | 0.259986 | 0.259986 | 4936.97 | 4936.97 | 3961.31 | 1.00 |
AIRLOOP F6 NE DXAC HEAT PUMP | 0.219979 | 0.219979 | 0.219979 | 0.219979 | 4283.98 | 4283.98 | 3971.34 | 1.00 |
AIRLOOP F6 N1 DXAC HEAT PUMP | 0.154271 | 0.154271 | 0.154271 | 0.154271 | 3151.76 | 3151.76 | 2668.07 | 1.00 |
AIRLOOP F6 N2 DXAC HEAT PUMP | 0.153116 | 0.153116 | 0.153116 | 0.153116 | 3134.29 | 3134.29 | 2667.94 | 1.00 |
AIRLOOP F6 S1 DXAC HEAT PUMP | 0.183863 | 0.183863 | 0.183863 | 0.183863 | 3649.20 | 3649.20 | 2658.44 | 1.00 |
AIRLOOP F6 S2 DXAC HEAT PUMP | 0.184590 | 0.184590 | 0.184590 | 0.184590 | 3659.69 | 3659.69 | 2658.31 | 1.00 |
AIRLOOP F7 SW DXAC HEAT PUMP | 0.292394 | 0.292394 | 0.292394 | 0.292394 | 5415.98 | 5415.98 | 4068.57 | 1.00 |
AIRLOOP F7 NW DXAC HEAT PUMP | 0.274713 | 0.274713 | 0.274713 | 0.274713 | 5141.65 | 5141.65 | 4079.63 | 1.00 |
AIRLOOP F7 SE DXAC HEAT PUMP | 0.260479 | 0.260479 | 0.260479 | 0.260479 | 4969.42 | 4969.42 | 4062.45 | 1.00 |
AIRLOOP F7 NE DXAC HEAT PUMP | 0.220125 | 0.220125 | 0.220125 | 0.220125 | 4309.83 | 4309.83 | 4073.52 | 1.00 |
AIRLOOP F7 N1 DXAC HEAT PUMP | 0.154294 | 0.154294 | 0.154294 | 0.154294 | 3165.69 | 3165.69 | 2735.99 | 1.00 |
AIRLOOP F7 N2 DXAC HEAT PUMP | 0.153146 | 0.153146 | 0.153146 | 0.153146 | 3148.25 | 3148.25 | 2735.84 | 1.00 |
AIRLOOP F7 S1 DXAC HEAT PUMP | 0.183825 | 0.183825 | 0.183825 | 0.183825 | 3663.51 | 3663.51 | 2725.31 | 1.00 |
AIRLOOP F7 S2 DXAC HEAT PUMP | 0.184551 | 0.184551 | 0.184551 | 0.184551 | 3674.01 | 3674.01 | 2725.16 | 1.00 |
AIRLOOP F8 SW DXAC HEAT PUMP | 0.293868 | 0.293868 | 0.293868 | 0.293868 | 5461.03 | 5461.03 | 4170.66 | 1.00 |
AIRLOOP F8 NW DXAC HEAT PUMP | 0.276214 | 0.276214 | 0.276214 | 0.276214 | 5186.55 | 5186.55 | 4182.34 | 1.00 |
AIRLOOP F8 SE DXAC HEAT PUMP | 0.262104 | 0.262104 | 0.262104 | 0.262104 | 5018.59 | 5018.59 | 4163.85 | 1.00 |
AIRLOOP F8 NE DXAC HEAT PUMP | 0.221399 | 0.221399 | 0.221399 | 0.221399 | 4349.83 | 4349.83 | 4175.53 | 1.00 |
AIRLOOP F8 N1 DXAC HEAT PUMP | 0.155546 | 0.155546 | 0.155546 | 0.155546 | 3196.64 | 3196.64 | 2807.41 | 1.00 |
AIRLOOP F8 N2 DXAC HEAT PUMP | 0.154405 | 0.154405 | 0.154405 | 0.154405 | 3179.28 | 3179.28 | 2807.24 | 1.00 |
AIRLOOP F8 S1 DXAC HEAT PUMP | 0.184963 | 0.184963 | 0.184963 | 0.184963 | 3693.53 | 3693.53 | 2796.09 | 1.00 |
AIRLOOP F8 S2 DXAC HEAT PUMP | 0.185689 | 0.185689 | 0.185689 | 0.185689 | 3704.06 | 3704.06 | 2795.93 | 1.00 |
AIRLOOP F9 SW DXAC HEAT PUMP | 0.304341 | 0.304341 | 0.304341 | 0.304341 | 5635.34 | 5635.34 | 4395.73 | 1.00 |
AIRLOOP F9 NW DXAC HEAT PUMP | 0.286786 | 0.286786 | 0.286786 | 0.286786 | 5362.55 | 5362.55 | 4405.55 | 1.00 |
AIRLOOP F9 SE DXAC HEAT PUMP | 0.270725 | 0.270725 | 0.270725 | 0.270725 | 5166.14 | 5166.14 | 4388.24 | 1.00 |
AIRLOOP F9 NE DXAC HEAT PUMP | 0.226726 | 0.226726 | 0.226726 | 0.226726 | 4448.79 | 4448.79 | 4398.07 | 1.00 |
AIRLOOP F9 N1 DXAC HEAT PUMP | 0.164652 | 0.164652 | 0.164652 | 0.164652 | 3344.92 | 3344.92 | 2993.63 | 1.00 |
AIRLOOP F9 N2 DXAC HEAT PUMP | 0.163497 | 0.163497 | 0.163497 | 0.163497 | 3327.41 | 3327.41 | 2993.45 | 1.00 |
AIRLOOP F9 S1 DXAC HEAT PUMP | 0.192123 | 0.192123 | 0.192123 | 0.192123 | 3813.81 | 3813.81 | 2983.73 | 1.00 |
AIRLOOP F9 S2 DXAC HEAT PUMP | 0.192824 | 0.192824 | 0.192824 | 0.192824 | 3823.95 | 3823.95 | 2983.55 | 1.00 |
AIRLOOP T SW DXAC HEAT PUMP | 0.375718 | 0.375718 | 0.375718 | 0.375718 | 6706.89 | 6706.89 | 5073.45 | 1.00 |
AIRLOOP T NW DXAC HEAT PUMP | 0.350598 | 0.350598 | 0.350598 | 0.350598 | 6326.19 | 6326.19 | 5089.95 | 1.00 |
AIRLOOP T SE DXAC HEAT PUMP | 0.338189 | 0.338189 | 0.338189 | 0.338189 | 6166.78 | 6166.78 | 5066.06 | 1.00 |
AIRLOOP T NE DXAC HEAT PUMP | 0.282672 | 0.282672 | 0.282672 | 0.282672 | 5304.64 | 5304.64 | 5082.56 | 1.00 |
AIRLOOP T N1 DXAC HEAT PUMP | 0.214058 | 0.214058 | 0.214058 | 0.214058 | 4146.95 | 4146.95 | 3709.98 | 1.00 |
AIRLOOP T N2 DXAC HEAT PUMP | 0.213784 | 0.213784 | 0.213784 | 0.213784 | 4142.53 | 4142.53 | 3709.78 | 1.00 |
AIRLOOP T S1 DXAC HEAT PUMP | 0.267214 | 0.267214 | 0.267214 | 0.267214 | 4916.02 | 4916.02 | 3690.38 | 1.00 |
AIRLOOP T S2 DXAC HEAT PUMP | 0.267903 | 0.267903 | 0.267903 | 0.267903 | 4925.75 | 4925.75 | 3690.19 | 1.00 |
Maximum Flow Rate [m3/s] | |
AIRLOOP G SW SUPPLY FAN | 0.219224 |
AIRLOOP G NW SUPPLY FAN | 0.205733 |
AIRLOOP OFFICE SUPPLY FAN | 0.328933 |
AIRLOOP G NE SUPPLY FAN | 0.157840 |
AIRLOOP G N1 SUPPLY FAN | 0.108913 |
AIRLOOP G N2 SUPPLY FAN | 0.107468 |
AIRLOOP G S1 SUPPLY FAN | 0.132272 |
AIRLOOP G S2 SUPPLY FAN | 0.138280 |
AIRLOOP F2 SW SUPPLY FAN | 0.283753 |
AIRLOOP F2 NW SUPPLY FAN | 0.265630 |
AIRLOOP F2 SE SUPPLY FAN | 0.272261 |
AIRLOOP F2 NE SUPPLY FAN | 0.210927 |
AIRLOOP F2 N1 SUPPLY FAN | 0.146132 |
AIRLOOP F2 N2 SUPPLY FAN | 0.144947 |
AIRLOOP F2 S1 SUPPLY FAN | 0.175773 |
AIRLOOP F2 S2 SUPPLY FAN | 0.177892 |
AIRLOOP F3 SW SUPPLY FAN | 0.286896 |
AIRLOOP F3 NW SUPPLY FAN | 0.269321 |
AIRLOOP F3 SE SUPPLY FAN | 0.256140 |
AIRLOOP F3 NE SUPPLY FAN | 0.215555 |
AIRLOOP F3 N1 SUPPLY FAN | 0.150198 |
AIRLOOP F3 N2 SUPPLY FAN | 0.149024 |
AIRLOOP F3 S1 SUPPLY FAN | 0.179923 |
AIRLOOP F3 S2 SUPPLY FAN | 0.180850 |
AIRLOOP F4 SW SUPPLY FAN | 0.289542 |
AIRLOOP F4 NW SUPPLY FAN | 0.271927 |
AIRLOOP F4 SE SUPPLY FAN | 0.257148 |
AIRLOOP F4 NE SUPPLY FAN | 0.217868 |
AIRLOOP F4 N1 SUPPLY FAN | 0.152434 |
AIRLOOP F4 N2 SUPPLY FAN | 0.151266 |
AIRLOOP F4 S1 SUPPLY FAN | 0.182107 |
AIRLOOP F4 S2 SUPPLY FAN | 0.182862 |
AIRLOOP M SW SUPPLY FAN | 0.293728 |
AIRLOOP M NW SUPPLY FAN | 0.276114 |
AIRLOOP M SE SUPPLY FAN | 0.261354 |
AIRLOOP M NE SUPPLY FAN | 0.221792 |
AIRLOOP M N1 SUPPLY FAN | 0.156153 |
AIRLOOP M N2 SUPPLY FAN | 0.154989 |
AIRLOOP M S1 SUPPLY FAN | 0.185785 |
AIRLOOP M S2 SUPPLY FAN | 0.186515 |
AIRLOOP F6 SW SUPPLY FAN | 0.292112 |
AIRLOOP F6 NW SUPPLY FAN | 0.274417 |
AIRLOOP F6 SE SUPPLY FAN | 0.259986 |
AIRLOOP F6 NE SUPPLY FAN | 0.219979 |
AIRLOOP F6 N1 SUPPLY FAN | 0.154271 |
AIRLOOP F6 N2 SUPPLY FAN | 0.153116 |
AIRLOOP F6 S1 SUPPLY FAN | 0.183863 |
AIRLOOP F6 S2 SUPPLY FAN | 0.184590 |
AIRLOOP F7 SW SUPPLY FAN | 0.292394 |
AIRLOOP F7 NW SUPPLY FAN | 0.274713 |
AIRLOOP F7 SE SUPPLY FAN | 0.260479 |
AIRLOOP F7 NE SUPPLY FAN | 0.220125 |
AIRLOOP F7 N1 SUPPLY FAN | 0.154294 |
AIRLOOP F7 N2 SUPPLY FAN | 0.153146 |
AIRLOOP F7 S1 SUPPLY FAN | 0.183825 |
AIRLOOP F7 S2 SUPPLY FAN | 0.184551 |
AIRLOOP F8 SW SUPPLY FAN | 0.293868 |
AIRLOOP F8 NW SUPPLY FAN | 0.276214 |
AIRLOOP F8 SE SUPPLY FAN | 0.262104 |
AIRLOOP F8 NE SUPPLY FAN | 0.221399 |
AIRLOOP F8 N1 SUPPLY FAN | 0.155546 |
AIRLOOP F8 N2 SUPPLY FAN | 0.154405 |
AIRLOOP F8 S1 SUPPLY FAN | 0.184963 |
AIRLOOP F8 S2 SUPPLY FAN | 0.185689 |
AIRLOOP F9 SW SUPPLY FAN | 0.304341 |
AIRLOOP F9 NW SUPPLY FAN | 0.286786 |
AIRLOOP F9 SE SUPPLY FAN | 0.270725 |
AIRLOOP F9 NE SUPPLY FAN | 0.226726 |
AIRLOOP F9 N1 SUPPLY FAN | 0.164652 |
AIRLOOP F9 N2 SUPPLY FAN | 0.163497 |
AIRLOOP F9 S1 SUPPLY FAN | 0.192123 |
AIRLOOP F9 S2 SUPPLY FAN | 0.192824 |
AIRLOOP T SW SUPPLY FAN | 0.375718 |
AIRLOOP T NW SUPPLY FAN | 0.350598 |
AIRLOOP T SE SUPPLY FAN | 0.338189 |
AIRLOOP T NE SUPPLY FAN | 0.282672 |
AIRLOOP T N1 SUPPLY FAN | 0.214058 |
AIRLOOP T N2 SUPPLY FAN | 0.213784 |
AIRLOOP T S1 SUPPLY FAN | 0.267214 |
AIRLOOP T S2 SUPPLY FAN | 0.267903 |
Rated Air Flow Rate [m3/s] | Rated Heating Capacity [W] | Rated Water Flow Rate [m3/s] | |
HEAT PUMP HEATING MODE AIRLOOP G SW | 0.219224 | 4068.34 | 0.000089 |
HEAT PUMP HEATING MODE AIRLOOP G NW | 0.205733 | 3852.75 | 0.000084 |
HEAT PUMP HEATING MODE AIRLOOP OFFICE | 0.328933 | 5969.90 | 0.000130 |
HEAT PUMP HEATING MODE AIRLOOP G NE | 0.157840 | 3125.32 | 0.000068 |
HEAT PUMP HEATING MODE AIRLOOP G N1 | 0.108913 | 2341.16 | 0.000051 |
HEAT PUMP HEATING MODE AIRLOOP G N2 | 0.107468 | 2319.26 | 0.000051 |
HEAT PUMP HEATING MODE AIRLOOP G S1 | 0.132272 | 2748.20 | 0.000060 |
HEAT PUMP HEATING MODE AIRLOOP G S2 | 0.138280 | 2835.58 | 0.000062 |
HEAT PUMP HEATING MODE AIRLOOP F2 SW | 0.283753 | 5089.12 | 0.000111 |
HEAT PUMP HEATING MODE AIRLOOP F2 NW | 0.265630 | 4813.92 | 0.000105 |
HEAT PUMP HEATING MODE AIRLOOP F2 SE | 0.272261 | 4949.47 | 0.000108 |
HEAT PUMP HEATING MODE AIRLOOP F2 NE | 0.210927 | 3988.74 | 0.000087 |
HEAT PUMP HEATING MODE AIRLOOP F2 N1 | 0.146132 | 2943.25 | 0.000064 |
HEAT PUMP HEATING MODE AIRLOOP F2 N2 | 0.144947 | 2925.58 | 0.000064 |
HEAT PUMP HEATING MODE AIRLOOP F2 S1 | 0.175773 | 3436.13 | 0.000075 |
HEAT PUMP HEATING MODE AIRLOOP F2 S2 | 0.177892 | 3466.69 | 0.000076 |
HEAT PUMP HEATING MODE AIRLOOP F3 SW | 0.286896 | 5194.08 | 0.000113 |
HEAT PUMP HEATING MODE AIRLOOP F3 NW | 0.269321 | 4925.64 | 0.000108 |
HEAT PUMP HEATING MODE AIRLOOP F3 SE | 0.256140 | 4775.27 | 0.000104 |
HEAT PUMP HEATING MODE AIRLOOP F3 NE | 0.215555 | 4110.79 | 0.000090 |
HEAT PUMP HEATING MODE AIRLOOP F3 N1 | 0.150198 | 3034.20 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP F3 N2 | 0.149024 | 3016.63 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP F3 S1 | 0.179923 | 3529.69 | 0.000077 |
HEAT PUMP HEATING MODE AIRLOOP F3 S2 | 0.180850 | 3543.01 | 0.000077 |
HEAT PUMP HEATING MODE AIRLOOP F4 SW | 0.289542 | 5282.11 | 0.000115 |
HEAT PUMP HEATING MODE AIRLOOP F4 NW | 0.271927 | 5006.65 | 0.000109 |
HEAT PUMP HEATING MODE AIRLOOP F4 SE | 0.257148 | 4832.38 | 0.000106 |
HEAT PUMP HEATING MODE AIRLOOP F4 NE | 0.217868 | 4184.98 | 0.000091 |
HEAT PUMP HEATING MODE AIRLOOP F4 N1 | 0.152434 | 3090.28 | 0.000068 |
HEAT PUMP HEATING MODE AIRLOOP F4 N2 | 0.151266 | 3072.72 | 0.000067 |
HEAT PUMP HEATING MODE AIRLOOP F4 S1 | 0.182107 | 3586.35 | 0.000078 |
HEAT PUMP HEATING MODE AIRLOOP F4 S2 | 0.182862 | 3597.21 | 0.000079 |
HEAT PUMP HEATING MODE AIRLOOP M SW | 0.293728 | 5378.50 | 0.000117 |
HEAT PUMP HEATING MODE AIRLOOP M NW | 0.276114 | 5102.44 | 0.000111 |
HEAT PUMP HEATING MODE AIRLOOP M SE | 0.261354 | 4927.95 | 0.000108 |
HEAT PUMP HEATING MODE AIRLOOP M NE | 0.221792 | 4283.46 | 0.000094 |
HEAT PUMP HEATING MODE AIRLOOP M N1 | 0.156153 | 3164.21 | 0.000069 |
HEAT PUMP HEATING MODE AIRLOOP M N2 | 0.154989 | 3146.69 | 0.000069 |
HEAT PUMP HEATING MODE AIRLOOP M S1 | 0.185785 | 3660.25 | 0.000080 |
HEAT PUMP HEATING MODE AIRLOOP M S2 | 0.186515 | 3670.77 | 0.000080 |
HEAT PUMP HEATING MODE AIRLOOP F6 SW | 0.292112 | 5385.45 | 0.000118 |
HEAT PUMP HEATING MODE AIRLOOP F6 NW | 0.274417 | 5111.59 | 0.000112 |
HEAT PUMP HEATING MODE AIRLOOP F6 SE | 0.259986 | 4936.97 | 0.000108 |
HEAT PUMP HEATING MODE AIRLOOP F6 NE | 0.219979 | 4283.98 | 0.000094 |
HEAT PUMP HEATING MODE AIRLOOP F6 N1 | 0.154271 | 3151.76 | 0.000069 |
HEAT PUMP HEATING MODE AIRLOOP F6 N2 | 0.153116 | 3134.29 | 0.000068 |
HEAT PUMP HEATING MODE AIRLOOP F6 S1 | 0.183863 | 3649.20 | 0.000080 |
HEAT PUMP HEATING MODE AIRLOOP F6 S2 | 0.184590 | 3659.69 | 0.000080 |
HEAT PUMP HEATING MODE AIRLOOP F7 SW | 0.292394 | 5415.98 | 0.000118 |
HEAT PUMP HEATING MODE AIRLOOP F7 NW | 0.274713 | 5141.65 | 0.000112 |
HEAT PUMP HEATING MODE AIRLOOP F7 SE | 0.260479 | 4969.42 | 0.000109 |
HEAT PUMP HEATING MODE AIRLOOP F7 NE | 0.220125 | 4309.83 | 0.000094 |
HEAT PUMP HEATING MODE AIRLOOP F7 N1 | 0.154294 | 3165.69 | 0.000069 |
HEAT PUMP HEATING MODE AIRLOOP F7 N2 | 0.153146 | 3148.25 | 0.000069 |
HEAT PUMP HEATING MODE AIRLOOP F7 S1 | 0.183825 | 3663.51 | 0.000080 |
HEAT PUMP HEATING MODE AIRLOOP F7 S2 | 0.184551 | 3674.01 | 0.000080 |
HEAT PUMP HEATING MODE AIRLOOP F8 SW | 0.293868 | 5461.03 | 0.000119 |
HEAT PUMP HEATING MODE AIRLOOP F8 NW | 0.276214 | 5186.55 | 0.000113 |
HEAT PUMP HEATING MODE AIRLOOP F8 SE | 0.262104 | 5018.59 | 0.000110 |
HEAT PUMP HEATING MODE AIRLOOP F8 NE | 0.221399 | 4349.83 | 0.000095 |
HEAT PUMP HEATING MODE AIRLOOP F8 N1 | 0.155546 | 3196.64 | 0.000070 |
HEAT PUMP HEATING MODE AIRLOOP F8 N2 | 0.154405 | 3179.28 | 0.000069 |
HEAT PUMP HEATING MODE AIRLOOP F8 S1 | 0.184963 | 3693.53 | 0.000081 |
HEAT PUMP HEATING MODE AIRLOOP F8 S2 | 0.185689 | 3704.06 | 0.000081 |
HEAT PUMP HEATING MODE AIRLOOP F9 SW | 0.304341 | 5635.34 | 0.000123 |
HEAT PUMP HEATING MODE AIRLOOP F9 NW | 0.286786 | 5362.55 | 0.000117 |
HEAT PUMP HEATING MODE AIRLOOP F9 SE | 0.270725 | 5166.14 | 0.000113 |
HEAT PUMP HEATING MODE AIRLOOP F9 NE | 0.226726 | 4448.79 | 0.000097 |
HEAT PUMP HEATING MODE AIRLOOP F9 N1 | 0.164652 | 3344.92 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F9 N2 | 0.163497 | 3327.41 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F9 S1 | 0.192123 | 3813.81 | 0.000083 |
HEAT PUMP HEATING MODE AIRLOOP F9 S2 | 0.192824 | 3823.95 | 0.000084 |
HEAT PUMP HEATING MODE AIRLOOP T SW | 0.375718 | 6706.89 | 0.000147 |
HEAT PUMP HEATING MODE AIRLOOP T NW | 0.350598 | 6326.19 | 0.000138 |
HEAT PUMP HEATING MODE AIRLOOP T SE | 0.338189 | 6166.78 | 0.000135 |
HEAT PUMP HEATING MODE AIRLOOP T NE | 0.282672 | 5304.64 | 0.000116 |
HEAT PUMP HEATING MODE AIRLOOP T N1 | 0.214058 | 4146.95 | 0.000091 |
HEAT PUMP HEATING MODE AIRLOOP T N2 | 0.213784 | 4142.53 | 0.000090 |
HEAT PUMP HEATING MODE AIRLOOP T S1 | 0.267214 | 4916.02 | 0.000107 |
HEAT PUMP HEATING MODE AIRLOOP T S2 | 0.267903 | 4925.75 | 0.000108 |
Nominal Capacity [W] | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW | 3554.23 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW | 3556.67 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE | 4397.18 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE | 3559.11 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 | 2688.13 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 | 2688.18 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 | 2682.34 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 | 2688.67 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW | 3559.06 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW | 3558.84 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE | 3577.66 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE | 3558.96 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 | 2466.31 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 | 2466.32 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 | 2469.33 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 | 2470.53 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW | 3633.94 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW | 3637.88 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE | 3634.13 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE | 3636.07 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 | 2473.05 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 | 2473.00 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 | 2469.93 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 | 2470.07 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW | 3748.75 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW | 3755.50 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE | 3745.71 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE | 3752.25 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 | 2533.53 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 | 2533.45 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 | 2527.29 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 | 2527.23 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW | 3832.84 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW | 3840.48 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE | 3828.49 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE | 3836.10 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 | 2573.04 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 | 2572.93 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 | 2565.80 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 | 2565.70 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW | 3966.63 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW | 3976.66 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE | 3961.31 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE | 3971.34 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 | 2668.07 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 | 2667.94 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 | 2658.44 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 | 2658.31 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW | 4068.57 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW | 4079.63 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE | 4062.45 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE | 4073.52 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 | 2735.99 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 | 2735.84 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 | 2725.31 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 | 2725.16 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW | 4170.66 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW | 4182.34 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE | 4163.85 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE | 4175.53 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 | 2807.41 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 | 2807.24 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 | 2796.09 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 | 2795.93 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW | 4395.73 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW | 4405.55 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE | 4388.24 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE | 4398.07 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 | 2993.63 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 | 2993.45 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 | 2983.73 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 | 2983.55 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW | 5073.45 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW | 5089.95 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE | 5066.06 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE | 5082.56 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 | 3709.98 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 | 3709.78 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 | 3690.38 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 | 3690.19 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
SHWSYS1 | 0.000289 | 0.325214 |
SINGLE WATER PLANT LOOP | 0.007321 | 8.24 |
Design Water Flow Rate [m3/s] | |
CENTRAL BOILER | 0.007321 |
Use Side Design Flow Rate [m3/s] | |
SHWSYS1 WATER HEATER | 0.000289 |
Design Water Flow Rate [m3/s] | Fan Power at Design Air Flow Rate [W] | Design Air Flow Rate [m3/s] | U-Factor Times Area Value at Design Air Flow Rate [W/C] | |
CENTRAL TOWER | 0.007321 | 3534.15 | 9.35 | 10909.27 |
Rated Flow Rate [m3/s] | Rated Power Consumption [W] | |
SHWSYS1 PUMP | 0.000289 | 36.93 |
PLANT CIRC PUMP | 0.007321 | 2337.93 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW3 | |
G WWALL SWA | GWINDOW2 | |
G NWALL NWA | GWINDOW4 | |
G WWALL NWA | GWINDOW6 | |
G SWALL SEA | GWINDOW1 | |
G EWALL SEA | GWINDOW8 | |
G NWALL NEA | GWINDOW5 | |
G EWALL NEA | GWINDOW7 | |
G NWALL N1A | GWINDOW9 | |
G NWALL N2A | GWINDOW10 | |
G SWALL S1A | GWINDOW11 | |
G SWALL S2A | GWINDOW12 | |
G WWALL C | GWINDOW13 | |
G EWALL C | ENTRANCE DOOR | |
F2 WWALL SWA | F2WINDOW2 | |
F2 SWALL SWA | F2WINDOW3 | |
F2 NWALL NWA | F2WINDOW4 | |
F2 WWALL NWA | F2WINDOW6 | |
F2 EWALL SEA | F2WINDOW8 | |
F2 SWALL SEA | F2WINDOW1 | |
F2 NWALL NEA | F2WINDOW5 | |
F2 EWALL NEA | F2WINDOW7 | |
F2 NWALL N1A | F2WINDOW9 | |
F2 NWALL N2A | F2WINDOW10 | |
F2 SWALL S1A | F2WINDOW11 | |
F2 SWALL S2A | F2WINDOW12 | |
F2 WWALL C | F2WINDOW13 | |
F2 EWALL C | F2WINDOW14 | |
F3 WWALL SWA | F3WINDOW2 | |
F3 SWALL SWA | F3WINDOW3 | |
F3 NWALL NWA | F3WINDOW4 | |
F3 WWALL NWA | F3WINDOW6 | |
F3 EWALL SEA | F3WINDOW8 | |
F3 SWALL SEA | F3WINDOW1 | |
F3 NWALL NEA | F3WINDOW5 | |
F3 EWALL NEA | F3WINDOW7 | |
F3 NWALL N1A | F3WINDOW9 | |
F3 NWALL N2A | F3WINDOW10 | |
F3 SWALL S1A | F3WINDOW11 | |
F3 SWALL S2A | F3WINDOW12 | |
F3 WWALL C | F3WINDOW13 | |
F3 EWALL C | F3WINDOW14 | |
F4 WWALL SWA | F4WINDOW2 | |
F4 SWALL SWA | F4WINDOW3 | |
F4 NWALL NWA | F4WINDOW4 | |
F4 WWALL NWA | F4WINDOW6 | |
F4 EWALL SEA | F4WINDOW8 | |
F4 SWALL SEA | F4WINDOW1 | |
F4 NWALL NEA | F4WINDOW5 | |
F4 EWALL NEA | F4WINDOW7 | |
F4 NWALL N1A | F4WINDOW9 | |
F4 NWALL N2A | F4WINDOW10 | |
F4 SWALL S1A | F4WINDOW11 | |
F4 SWALL S2A | F4WINDOW12 | |
F4 WWALL C | F4WINDOW13 | |
F4 EWALL C | F4WINDOW14 | |
M WWALL SWA | MWINDOW2 | |
M SWALL SWA | MWINDOW3 | |
M NWALL NWA | MWINDOW4 | |
M WWALL NWA | MWINDOW6 | |
M EWALL SEA | MWINDOW8 | |
M SWALL SEA | MWINDOW1 | |
M NWALL NEA | MWINDOW5 | |
M EWALL NEA | MWINDOW7 | |
M NWALL N1A | MWINDOW9 | |
M NWALL N2A | MWINDOW10 | |
M SWALL S1A | MWINDOW11 | |
M SWALL S2A | MWINDOW12 | |
M WWALL C | MWINDOW13 | |
M EWALL C | MWINDOW14 | |
F6 WWALL SWA | F6WINDOW2 | |
F6 SWALL SWA | F6WINDOW3 | |
F6 NWALL NWA | F6WINDOW4 | |
F6 WWALL NWA | F6WINDOW6 | |
F6 EWALL SEA | F6WINDOW8 | |
F6 SWALL SEA | F6WINDOW1 | |
F6 NWALL NEA | F6WINDOW5 | |
F6 EWALL NEA | F6WINDOW7 | |
F6 NWALL N1A | F6WINDOW9 | |
F6 NWALL N2A | F6WINDOW10 | |
F6 SWALL S1A | F6WINDOW11 | |
F6 SWALL S2A | F6WINDOW12 | |
F6 WWALL C | F6WINDOW13 | |
F6 EWALL C | F6WINDOW14 | |
F7 WWALL SWA | F7WINDOW2 | |
F7 SWALL SWA | F7WINDOW3 | |
F7 NWALL NWA | F7WINDOW4 | |
F7 WWALL NWA | F7WINDOW6 | |
F7 EWALL SEA | F7WINDOW8 | |
F7 SWALL SEA | F7WINDOW1 | |
F7 NWALL NEA | F7WINDOW5 | |
F7 EWALL NEA | F7WINDOW7 | |
F7 NWALL N1A | F7WINDOW9 | |
F7 NWALL N2A | F7WINDOW10 | |
F7 SWALL S1A | F7WINDOW11 | |
F7 SWALL S2A | F7WINDOW12 | |
F7 WWALL C | F7WINDOW13 | |
F7 EWALL C | F7WINDOW14 | |
F8 WWALL SWA | F8WINDOW2 | |
F8 SWALL SWA | F8WINDOW3 | |
F8 NWALL NWA | F8WINDOW4 | |
F8 WWALL NWA | F8WINDOW6 | |
F8 EWALL SEA | F8WINDOW8 | |
F8 SWALL SEA | F8WINDOW1 | |
F8 NWALL NEA | F8WINDOW5 | |
F8 EWALL NEA | F8WINDOW7 | |
F8 NWALL N1A | F8WINDOW9 | |
F8 NWALL N2A | F8WINDOW10 | |
F8 SWALL S1A | F8WINDOW11 | |
F8 SWALL S2A | F8WINDOW12 | |
F8 WWALL C | F8WINDOW13 | |
F8 EWALL C | F8WINDOW14 | |
F9 WWALL SWA | F9WINDOW2 | |
F9 SWALL SWA | F9WINDOW3 | |
F9 NWALL NWA | F9WINDOW4 | |
F9 WWALL NWA | F9WINDOW6 | |
F9 EWALL SEA | F9WINDOW8 | |
F9 SWALL SEA | F9WINDOW1 | |
F9 NWALL NEA | F9WINDOW5 | |
F9 EWALL NEA | F9WINDOW7 | |
F9 NWALL N1A | F9WINDOW9 | |
F9 NWALL N2A | F9WINDOW10 | |
F9 SWALL S1A | F9WINDOW11 | |
F9 SWALL S2A | F9WINDOW12 | |
F9 WWALL C | F9WINDOW13 | |
F9 EWALL C | F9WINDOW14 | |
T WWALL SWA | TWINDOW2 | |
T SWALL SWA | TWINDOW3 | |
T NWALL NWA | TWINDOW4 | |
T WWALL NWA | TWINDOW6 | |
T EWALL SEA | TWINDOW8 | |
T SWALL SEA | TWINDOW1 | |
T NWALL NEA | TWINDOW5 | |
T EWALL NEA | TWINDOW7 | |
T NWALL N1A | TWINDOW9 | |
T NWALL N2A | TWINDOW10 | |
T SWALL S1A | TWINDOW11 | |
T SWALL S2A | TWINDOW12 | |
T WWALL C | TWINDOW13 | |
T EWALL C | TWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2015-09-09 19:00:30
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.76 | -0.5 |
February | 21.83 | 2.24 |
March | 22.28 | 8.00 |
April | 22.77 | 13.18 |
May | 23.46 | 18.32 |
June | 24.30 | 22.93 |
July | 24.39 | 25.34 |
August | 24.35 | 24.28 |
September | 24.22 | 20.44 |
October | 23.18 | 12.66 |
November | 22.33 | 8.91 |
December | 21.88 | 2.07 |
Annual Sum or Average | 23.07 | 13.21 |
Minimum of Months | 21.76 | -0.5 |
Maximum of Months | 24.39 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 21.93 | 8.00 |
April | 22.40 | 13.18 |
May | 23.38 | 18.32 |
June | 24.30 | 22.93 |
July | 24.40 | 25.34 |
August | 24.34 | 24.28 |
September | 24.13 | 20.44 |
October | 22.54 | 12.66 |
November | 21.80 | 8.91 |
December | 21.73 | 2.07 |
Annual Sum or Average | 22.87 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.92 | -0.5 |
February | 22.15 | 2.24 |
March | 22.67 | 8.00 |
April | 23.33 | 13.18 |
May | 23.92 | 18.32 |
June | 24.38 | 22.93 |
July | 24.40 | 25.34 |
August | 24.40 | 24.28 |
September | 24.36 | 20.44 |
October | 23.47 | 12.66 |
November | 22.80 | 8.91 |
December | 22.13 | 2.07 |
Annual Sum or Average | 23.33 | 13.21 |
Minimum of Months | 21.92 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.70 | 2.24 |
March | 21.89 | 8.00 |
April | 22.30 | 13.18 |
May | 23.31 | 18.32 |
June | 24.30 | 22.93 |
July | 24.40 | 25.34 |
August | 24.34 | 24.28 |
September | 24.11 | 20.44 |
October | 22.44 | 12.66 |
November | 21.76 | 8.91 |
December | 21.72 | 2.07 |
Annual Sum or Average | 22.84 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.70 | 2.24 |
March | 21.87 | 8.00 |
April | 22.16 | 13.18 |
May | 23.19 | 18.32 |
June | 24.27 | 22.93 |
July | 24.40 | 25.34 |
August | 24.33 | 24.28 |
September | 24.06 | 20.44 |
October | 22.40 | 12.66 |
November | 21.76 | 8.91 |
December | 21.72 | 2.07 |
Annual Sum or Average | 22.80 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.70 | 2.24 |
March | 21.87 | 8.00 |
April | 22.15 | 13.18 |
May | 23.18 | 18.32 |
June | 24.27 | 22.93 |
July | 24.40 | 25.34 |
August | 24.33 | 24.28 |
September | 24.06 | 20.44 |
October | 22.39 | 12.66 |
November | 21.76 | 8.91 |
December | 21.72 | 2.07 |
Annual Sum or Average | 22.80 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.78 | -0.5 |
February | 21.84 | 2.24 |
March | 22.27 | 8.00 |
April | 22.67 | 13.18 |
May | 23.36 | 18.32 |
June | 24.28 | 22.93 |
July | 24.39 | 25.34 |
August | 24.35 | 24.28 |
September | 24.22 | 20.44 |
October | 23.24 | 12.66 |
November | 22.42 | 8.91 |
December | 21.91 | 2.07 |
Annual Sum or Average | 23.07 | 13.21 |
Minimum of Months | 21.78 | -0.5 |
Maximum of Months | 24.39 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.79 | -0.5 |
February | 21.86 | 2.24 |
March | 22.31 | 8.00 |
April | 22.74 | 13.18 |
May | 23.41 | 18.32 |
June | 24.29 | 22.93 |
July | 24.39 | 25.34 |
August | 24.35 | 24.28 |
September | 24.23 | 20.44 |
October | 23.29 | 12.66 |
November | 22.47 | 8.91 |
December | 21.93 | 2.07 |
Annual Sum or Average | 23.10 | 13.21 |
Minimum of Months | 21.79 | -0.5 |
Maximum of Months | 24.39 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 15.27 | -0.5 |
February | 16.24 | 2.24 |
March | 18.40 | 8.00 |
April | 20.48 | 13.18 |
May | 22.67 | 18.32 |
June | 25.24 | 22.93 |
July | 26.09 | 25.34 |
August | 25.73 | 24.28 |
September | 24.19 | 20.44 |
October | 20.59 | 12.66 |
November | 18.73 | 8.91 |
December | 16.23 | 2.07 |
Annual Sum or Average | 20.84 | 13.21 |
Minimum of Months | 15.27 | -0.5 |
Maximum of Months | 26.09 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F2 SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.82 | -0.5 |
February | 21.96 | 2.24 |
March | 22.68 | 8.00 |
April | 23.66 | 13.18 |
May | 24.05 | 18.32 |
June | 24.36 | 22.93 |
July | 24.40 | 25.34 |
August | 24.38 | 24.28 |
September | 24.33 | 20.44 |
October | 23.77 | 12.66 |
November | 22.91 | 8.91 |
December | 22.07 | 2.07 |
Annual Sum or Average | 23.37 | 13.21 |
Minimum of Months | 21.82 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F2 NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.72 | 2.24 |
March | 22.09 | 8.00 |
April | 23.16 | 13.18 |
May | 23.96 | 18.32 |
June | 24.36 | 22.93 |
July | 24.40 | 25.34 |
August | 24.37 | 24.28 |
September | 24.26 | 20.44 |
October | 23.09 | 12.66 |
November | 21.94 | 8.91 |
December | 21.77 | 2.07 |
Annual Sum or Average | 23.08 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F2 SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.84 | -0.5 |
February | 22.03 | 2.24 |
March | 22.82 | 8.00 |
April | 23.81 | 13.18 |
May | 24.14 | 18.32 |
June | 24.38 | 22.93 |
July | 24.40 | 25.34 |
August | 24.38 | 24.28 |
September | 24.35 | 20.44 |
October | 23.85 | 12.66 |
November | 23.03 | 8.91 |
December | 22.10 | 2.07 |
Annual Sum or Average | 23.43 | 13.21 |
Minimum of Months | 21.84 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F2 NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 22.04 | 8.00 |
April | 23.04 | 13.18 |
May | 23.91 | 18.32 |
June | 24.37 | 22.93 |
July | 24.41 | 25.34 |
August | 24.36 | 24.28 |
September | 24.25 | 20.44 |
October | 22.98 | 12.66 |
November | 21.87 | 8.91 |
December | 21.76 | 2.07 |
Annual Sum or Average | 23.04 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.41 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F2 N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 22.03 | 8.00 |
April | 22.93 | 13.18 |
May | 23.86 | 18.32 |
June | 24.35 | 22.93 |
July | 24.40 | 25.34 |
August | 24.36 | 24.28 |
September | 24.21 | 20.44 |
October | 22.99 | 12.66 |
November | 21.91 | 8.91 |
December | 21.77 | 2.07 |
Annual Sum or Average | 23.03 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F2 N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 22.03 | 8.00 |
April | 22.92 | 13.18 |
May | 23.85 | 18.32 |
June | 24.35 | 22.93 |
July | 24.40 | 25.34 |
August | 24.36 | 24.28 |
September | 24.21 | 20.44 |
October | 22.98 | 12.66 |
November | 21.91 | 8.91 |
December | 21.77 | 2.07 |
Annual Sum or Average | 23.02 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F2 S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.91 | -0.5 |
February | 22.05 | 2.24 |
March | 22.82 | 8.00 |
April | 23.65 | 13.18 |
May | 24.02 | 18.32 |
June | 24.36 | 22.93 |
July | 24.40 | 25.34 |
August | 24.38 | 24.28 |
September | 24.33 | 20.44 |
October | 23.88 | 12.66 |
November | 23.15 | 8.91 |
December | 22.18 | 2.07 |
Annual Sum or Average | 23.43 | 13.21 |
Minimum of Months | 21.91 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F2 S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.92 | -0.5 |
February | 22.07 | 2.24 |
March | 22.84 | 8.00 |
April | 23.68 | 13.18 |
May | 24.03 | 18.32 |
June | 24.36 | 22.93 |
July | 24.40 | 25.34 |
August | 24.38 | 24.28 |
September | 24.33 | 20.44 |
October | 23.89 | 12.66 |
November | 23.18 | 8.91 |
December | 22.19 | 2.07 |
Annual Sum or Average | 23.44 | 13.21 |
Minimum of Months | 21.92 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F2 CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.32 | -0.5 |
February | 21.69 | 2.24 |
March | 22.86 | 8.00 |
April | 24.25 | 13.18 |
May | 25.29 | 18.32 |
June | 26.32 | 22.93 |
July | 26.56 | 25.34 |
August | 26.45 | 24.28 |
September | 25.95 | 20.44 |
October | 24.34 | 12.66 |
November | 22.99 | 8.91 |
December | 21.71 | 2.07 |
Annual Sum or Average | 24.16 | 13.21 |
Minimum of Months | 21.32 | -0.5 |
Maximum of Months | 26.56 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F3 SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.81 | -0.5 |
February | 21.95 | 2.24 |
March | 22.72 | 8.00 |
April | 23.78 | 13.18 |
May | 24.13 | 18.32 |
June | 24.36 | 22.93 |
July | 24.40 | 25.34 |
August | 24.38 | 24.28 |
September | 24.33 | 20.44 |
October | 23.83 | 12.66 |
November | 23.00 | 8.91 |
December | 22.09 | 2.07 |
Annual Sum or Average | 23.41 | 13.21 |
Minimum of Months | 21.81 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F3 NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.72 | 2.24 |
March | 22.11 | 8.00 |
April | 23.31 | 13.18 |
May | 24.05 | 18.32 |
June | 24.36 | 22.93 |
July | 24.40 | 25.34 |
August | 24.36 | 24.28 |
September | 24.26 | 20.44 |
October | 23.20 | 12.66 |
November | 21.97 | 8.91 |
December | 21.78 | 2.07 |
Annual Sum or Average | 23.11 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F3 SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.80 | -0.5 |
February | 21.96 | 2.24 |
March | 22.75 | 8.00 |
April | 23.80 | 13.18 |
May | 24.15 | 18.32 |
June | 24.37 | 22.93 |
July | 24.40 | 25.34 |
August | 24.38 | 24.28 |
September | 24.34 | 20.44 |
October | 23.83 | 12.66 |
November | 22.98 | 8.91 |
December | 22.05 | 2.07 |
Annual Sum or Average | 23.41 | 13.21 |
Minimum of Months | 21.80 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F3 NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 22.07 | 8.00 |
April | 23.20 | 13.18 |
May | 24.01 | 18.32 |
June | 24.37 | 22.93 |
July | 24.41 | 25.34 |
August | 24.36 | 24.28 |
September | 24.25 | 20.44 |
October | 23.11 | 12.66 |
November | 21.89 | 8.91 |
December | 21.76 | 2.07 |
Annual Sum or Average | 23.08 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.41 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F3 N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.72 | 2.24 |
March | 22.08 | 8.00 |
April | 23.16 | 13.18 |
May | 24.00 | 18.32 |
June | 24.35 | 22.93 |
July | 24.40 | 25.34 |
August | 24.36 | 24.28 |
September | 24.22 | 20.44 |
October | 23.17 | 12.66 |
November | 21.97 | 8.91 |
December | 21.79 | 2.07 |
Annual Sum or Average | 23.08 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F3 N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.72 | 2.24 |
March | 22.08 | 8.00 |
April | 23.15 | 13.18 |
May | 23.99 | 18.32 |
June | 24.35 | 22.93 |
July | 24.40 | 25.34 |
August | 24.36 | 24.28 |
September | 24.22 | 20.44 |
October | 23.16 | 12.66 |
November | 21.97 | 8.91 |
December | 21.79 | 2.07 |
Annual Sum or Average | 23.08 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F3 S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.93 | -0.5 |
February | 22.10 | 2.24 |
March | 22.94 | 8.00 |
April | 23.84 | 13.18 |
May | 24.13 | 18.32 |
June | 24.36 | 22.93 |
July | 24.40 | 25.34 |
August | 24.38 | 24.28 |
September | 24.33 | 20.44 |
October | 23.97 | 12.66 |
November | 23.34 | 8.91 |
December | 22.24 | 2.07 |
Annual Sum or Average | 23.50 | 13.21 |
Minimum of Months | 21.93 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F3 S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.93 | -0.5 |
February | 22.10 | 2.24 |
March | 22.95 | 8.00 |
April | 23.85 | 13.18 |
May | 24.14 | 18.32 |
June | 24.36 | 22.93 |
July | 24.40 | 25.34 |
August | 24.38 | 24.28 |
September | 24.33 | 20.44 |
October | 23.97 | 12.66 |
November | 23.34 | 8.91 |
December | 22.24 | 2.07 |
Annual Sum or Average | 23.51 | 13.21 |
Minimum of Months | 21.93 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F3 CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.83 | -0.5 |
February | 22.14 | 2.24 |
March | 23.29 | 8.00 |
April | 24.75 | 13.18 |
May | 25.70 | 18.32 |
June | 26.45 | 22.93 |
July | 26.65 | 25.34 |
August | 26.54 | 24.28 |
September | 26.11 | 20.44 |
October | 24.78 | 12.66 |
November | 23.43 | 8.91 |
December | 22.18 | 2.07 |
Annual Sum or Average | 24.50 | 13.21 |
Minimum of Months | 21.83 | -0.5 |
Maximum of Months | 26.65 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F4 SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.80 | -0.5 |
February | 21.93 | 2.24 |
March | 22.70 | 8.00 |
April | 23.77 | 13.18 |
May | 24.14 | 18.32 |
June | 24.36 | 22.93 |
July | 24.40 | 25.34 |
August | 24.38 | 24.28 |
September | 24.33 | 20.44 |
October | 23.82 | 12.66 |
November | 23.00 | 8.91 |
December | 22.08 | 2.07 |
Annual Sum or Average | 23.40 | 13.21 |
Minimum of Months | 21.80 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F4 NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.72 | 2.24 |
March | 22.12 | 8.00 |
April | 23.30 | 13.18 |
May | 24.06 | 18.32 |
June | 24.36 | 22.93 |
July | 24.40 | 25.34 |
August | 24.37 | 24.28 |
September | 24.26 | 20.44 |
October | 23.21 | 12.66 |
November | 21.98 | 8.91 |
December | 21.78 | 2.07 |
Annual Sum or Average | 23.11 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F4 SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.78 | -0.5 |
February | 21.93 | 2.24 |
March | 22.71 | 8.00 |
April | 23.75 | 13.18 |
May | 24.15 | 18.32 |
June | 24.37 | 22.93 |
July | 24.40 | 25.34 |
August | 24.38 | 24.28 |
September | 24.34 | 20.44 |
October | 23.80 | 12.66 |
November | 22.94 | 8.91 |
December | 22.03 | 2.07 |
Annual Sum or Average | 23.39 | 13.21 |
Minimum of Months | 21.78 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F4 NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 22.07 | 8.00 |
April | 23.20 | 13.18 |
May | 24.03 | 18.32 |
June | 24.37 | 22.93 |
July | 24.41 | 25.34 |
August | 24.37 | 24.28 |
September | 24.25 | 20.44 |
October | 23.12 | 12.66 |
November | 21.90 | 8.91 |
December | 21.76 | 2.07 |
Annual Sum or Average | 23.08 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.41 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F4 N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -0.5 |
February | 21.72 | 2.24 |
March | 22.10 | 8.00 |
April | 23.20 | 13.18 |
May | 24.04 | 18.32 |
June | 24.35 | 22.93 |
July | 24.40 | 25.34 |
August | 24.36 | 24.28 |
September | 24.22 | 20.44 |
October | 23.21 | 12.66 |
November | 22.00 | 8.91 |
December | 21.79 | 2.07 |
Annual Sum or Average | 23.10 | 13.21 |
Minimum of Months | 21.71 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F4 N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -0.5 |
February | 21.72 | 2.24 |
March | 22.10 | 8.00 |
April | 23.19 | 13.18 |
May | 24.03 | 18.32 |
June | 24.35 | 22.93 |
July | 24.41 | 25.34 |
August | 24.36 | 24.28 |
September | 24.22 | 20.44 |
October | 23.20 | 12.66 |
November | 22.00 | 8.91 |
December | 21.79 | 2.07 |
Annual Sum or Average | 23.10 | 13.21 |
Minimum of Months | 21.71 | -0.5 |
Maximum of Months | 24.41 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F4 S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.92 | -0.5 |
February | 22.09 | 2.24 |
March | 22.95 | 8.00 |
April | 23.85 | 13.18 |
May | 24.16 | 18.32 |
June | 24.36 | 22.93 |
July | 24.40 | 25.34 |
August | 24.38 | 24.28 |
September | 24.33 | 20.44 |
October | 23.97 | 12.66 |
November | 23.36 | 8.91 |
December | 22.24 | 2.07 |
Annual Sum or Average | 23.51 | 13.21 |
Minimum of Months | 21.92 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F4 S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.92 | -0.5 |
February | 22.09 | 2.24 |
March | 22.96 | 8.00 |
April | 23.86 | 13.18 |
May | 24.16 | 18.32 |
June | 24.36 | 22.93 |
July | 24.40 | 25.34 |
August | 24.38 | 24.28 |
September | 24.33 | 20.44 |
October | 23.97 | 12.66 |
November | 23.36 | 8.91 |
December | 22.23 | 2.07 |
Annual Sum or Average | 23.51 | 13.21 |
Minimum of Months | 21.92 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F4 CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.95 | -0.5 |
February | 22.26 | 2.24 |
March | 23.41 | 8.00 |
April | 24.90 | 13.18 |
May | 25.85 | 18.32 |
June | 26.54 | 22.93 |
July | 26.73 | 25.34 |
August | 26.63 | 24.28 |
September | 26.19 | 20.44 |
October | 24.92 | 12.66 |
November | 23.56 | 8.91 |
December | 22.30 | 2.07 |
Annual Sum or Average | 24.61 | 13.21 |
Minimum of Months | 21.95 | -0.5 |
Maximum of Months | 26.73 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.79 | -0.5 |
February | 21.92 | 2.24 |
March | 22.66 | 8.00 |
April | 23.73 | 13.18 |
May | 24.13 | 18.32 |
June | 24.36 | 22.93 |
July | 24.40 | 25.34 |
August | 24.38 | 24.28 |
September | 24.33 | 20.44 |
October | 23.81 | 12.66 |
November | 22.97 | 8.91 |
December | 22.06 | 2.07 |
Annual Sum or Average | 23.39 | 13.21 |
Minimum of Months | 21.79 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.72 | 2.24 |
March | 22.11 | 8.00 |
April | 23.27 | 13.18 |
May | 24.05 | 18.32 |
June | 24.36 | 22.93 |
July | 24.40 | 25.34 |
August | 24.37 | 24.28 |
September | 24.25 | 20.44 |
October | 23.20 | 12.66 |
November | 21.98 | 8.91 |
December | 21.78 | 2.07 |
Annual Sum or Average | 23.11 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.78 | -0.5 |
February | 21.91 | 2.24 |
March | 22.67 | 8.00 |
April | 23.71 | 13.18 |
May | 24.13 | 18.32 |
June | 24.37 | 22.93 |
July | 24.40 | 25.34 |
August | 24.38 | 24.28 |
September | 24.33 | 20.44 |
October | 23.79 | 12.66 |
November | 22.91 | 8.91 |
December | 22.01 | 2.07 |
Annual Sum or Average | 23.37 | 13.21 |
Minimum of Months | 21.78 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 22.06 | 8.00 |
April | 23.17 | 13.18 |
May | 24.02 | 18.32 |
June | 24.36 | 22.93 |
July | 24.41 | 25.34 |
August | 24.36 | 24.28 |
September | 24.24 | 20.44 |
October | 23.11 | 12.66 |
November | 21.90 | 8.91 |
December | 21.76 | 2.07 |
Annual Sum or Average | 23.08 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.41 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -0.5 |
February | 21.72 | 2.24 |
March | 22.10 | 8.00 |
April | 23.19 | 13.18 |
May | 24.03 | 18.32 |
June | 24.35 | 22.93 |
July | 24.40 | 25.34 |
August | 24.36 | 24.28 |
September | 24.22 | 20.44 |
October | 23.22 | 12.66 |
November | 22.01 | 8.91 |
December | 21.79 | 2.07 |
Annual Sum or Average | 23.10 | 13.21 |
Minimum of Months | 21.71 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -0.5 |
February | 21.72 | 2.24 |
March | 22.10 | 8.00 |
April | 23.18 | 13.18 |
May | 24.03 | 18.32 |
June | 24.35 | 22.93 |
July | 24.41 | 25.34 |
August | 24.36 | 24.28 |
September | 24.22 | 20.44 |
October | 23.21 | 12.66 |
November | 22.01 | 8.91 |
December | 21.79 | 2.07 |
Annual Sum or Average | 23.10 | 13.21 |
Minimum of Months | 21.71 | -0.5 |
Maximum of Months | 24.41 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.91 | -0.5 |
February | 22.07 | 2.24 |
March | 22.93 | 8.00 |
April | 23.83 | 13.18 |
May | 24.16 | 18.32 |
June | 24.35 | 22.93 |
July | 24.40 | 25.34 |
August | 24.38 | 24.28 |
September | 24.33 | 20.44 |
October | 23.97 | 12.66 |
November | 23.35 | 8.91 |
December | 22.23 | 2.07 |
Annual Sum or Average | 23.50 | 13.21 |
Minimum of Months | 21.91 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.91 | -0.5 |
February | 22.07 | 2.24 |
March | 22.93 | 8.00 |
April | 23.84 | 13.18 |
May | 24.16 | 18.32 |
June | 24.35 | 22.93 |
July | 24.40 | 25.34 |
August | 24.38 | 24.28 |
September | 24.33 | 20.44 |
October | 23.97 | 12.66 |
November | 23.35 | 8.91 |
December | 22.22 | 2.07 |
Annual Sum or Average | 23.50 | 13.21 |
Minimum of Months | 21.91 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.51 | -0.5 |
February | 22.80 | 2.24 |
March | 23.95 | 8.00 |
April | 25.42 | 13.18 |
May | 26.39 | 18.32 |
June | 27.07 | 22.93 |
July | 27.26 | 25.34 |
August | 27.16 | 24.28 |
September | 26.73 | 20.44 |
October | 25.47 | 12.66 |
November | 24.11 | 8.91 |
December | 22.87 | 2.07 |
Annual Sum or Average | 25.16 | 13.21 |
Minimum of Months | 22.51 | -0.5 |
Maximum of Months | 27.26 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F6 SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.77 | -0.5 |
February | 21.88 | 2.24 |
March | 22.57 | 8.00 |
April | 23.62 | 13.18 |
May | 24.08 | 18.32 |
June | 24.35 | 22.93 |
July | 24.40 | 25.34 |
August | 24.38 | 24.28 |
September | 24.32 | 20.44 |
October | 23.76 | 12.66 |
November | 22.86 | 8.91 |
December | 22.02 | 2.07 |
Annual Sum or Average | 23.34 | 13.21 |
Minimum of Months | 21.77 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F6 NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.72 | 2.24 |
March | 22.07 | 8.00 |
April | 23.14 | 13.18 |
May | 23.99 | 18.32 |
June | 24.35 | 22.93 |
July | 24.40 | 25.34 |
August | 24.36 | 24.28 |
September | 24.22 | 20.44 |
October | 23.11 | 12.66 |
November | 21.94 | 8.91 |
December | 21.77 | 2.07 |
Annual Sum or Average | 23.07 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F6 SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.76 | -0.5 |
February | 21.88 | 2.24 |
March | 22.57 | 8.00 |
April | 23.59 | 13.18 |
May | 24.08 | 18.32 |
June | 24.36 | 22.93 |
July | 24.40 | 25.34 |
August | 24.38 | 24.28 |
September | 24.32 | 20.44 |
October | 23.74 | 12.66 |
November | 22.80 | 8.91 |
December | 21.97 | 2.07 |
Annual Sum or Average | 23.33 | 13.21 |
Minimum of Months | 21.76 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F6 NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 22.03 | 8.00 |
April | 23.03 | 13.18 |
May | 23.95 | 18.32 |
June | 24.36 | 22.93 |
July | 24.41 | 25.34 |
August | 24.36 | 24.28 |
September | 24.20 | 20.44 |
October | 23.02 | 12.66 |
November | 21.87 | 8.91 |
December | 21.75 | 2.07 |
Annual Sum or Average | 23.04 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.41 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F6 N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 22.06 | 8.00 |
April | 23.06 | 13.18 |
May | 23.97 | 18.32 |
June | 24.34 | 22.93 |
July | 24.40 | 25.34 |
August | 24.35 | 24.28 |
September | 24.19 | 20.44 |
October | 23.13 | 12.66 |
November | 21.96 | 8.91 |
December | 21.78 | 2.07 |
Annual Sum or Average | 23.06 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F6 N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 22.06 | 8.00 |
April | 23.05 | 13.18 |
May | 23.96 | 18.32 |
June | 24.34 | 22.93 |
July | 24.40 | 25.34 |
August | 24.35 | 24.28 |
September | 24.19 | 20.44 |
October | 23.12 | 12.66 |
November | 21.95 | 8.91 |
December | 21.78 | 2.07 |
Annual Sum or Average | 23.06 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F6 S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.88 | -0.5 |
February | 22.02 | 2.24 |
March | 22.83 | 8.00 |
April | 23.73 | 13.18 |
May | 24.11 | 18.32 |
June | 24.35 | 22.93 |
July | 24.40 | 25.34 |
August | 24.38 | 24.28 |
September | 24.32 | 20.44 |
October | 23.92 | 12.66 |
November | 23.23 | 8.91 |
December | 22.17 | 2.07 |
Annual Sum or Average | 23.45 | 13.21 |
Minimum of Months | 21.88 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F6 S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.88 | -0.5 |
February | 22.02 | 2.24 |
March | 22.83 | 8.00 |
April | 23.73 | 13.18 |
May | 24.11 | 18.32 |
June | 24.35 | 22.93 |
July | 24.40 | 25.34 |
August | 24.38 | 24.28 |
September | 24.32 | 20.44 |
October | 23.92 | 12.66 |
November | 23.23 | 8.91 |
December | 22.17 | 2.07 |
Annual Sum or Average | 23.45 | 13.21 |
Minimum of Months | 21.88 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F6 CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.87 | -0.5 |
February | 22.17 | 2.24 |
March | 23.30 | 8.00 |
April | 24.75 | 13.18 |
May | 25.78 | 18.32 |
June | 26.52 | 22.93 |
July | 26.72 | 25.34 |
August | 26.61 | 24.28 |
September | 26.15 | 20.44 |
October | 24.84 | 12.66 |
November | 23.46 | 8.91 |
December | 22.22 | 2.07 |
Annual Sum or Average | 24.54 | 13.21 |
Minimum of Months | 21.87 | -0.5 |
Maximum of Months | 26.72 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F7 SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.76 | -0.5 |
February | 21.86 | 2.24 |
March | 22.50 | 8.00 |
April | 23.53 | 13.18 |
May | 24.04 | 18.32 |
June | 24.35 | 22.93 |
July | 24.40 | 25.34 |
August | 24.37 | 24.28 |
September | 24.30 | 20.44 |
October | 23.71 | 12.66 |
November | 22.78 | 8.91 |
December | 21.99 | 2.07 |
Annual Sum or Average | 23.31 | 13.21 |
Minimum of Months | 21.76 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F7 NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 22.05 | 8.00 |
April | 23.04 | 13.18 |
May | 23.94 | 18.32 |
June | 24.34 | 22.93 |
July | 24.40 | 25.34 |
August | 24.36 | 24.28 |
September | 24.20 | 20.44 |
October | 23.04 | 12.66 |
November | 21.91 | 8.91 |
December | 21.76 | 2.07 |
Annual Sum or Average | 23.04 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F7 SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.75 | -0.5 |
February | 21.85 | 2.24 |
March | 22.51 | 8.00 |
April | 23.49 | 13.18 |
May | 24.03 | 18.32 |
June | 24.36 | 22.93 |
July | 24.40 | 25.34 |
August | 24.38 | 24.28 |
September | 24.31 | 20.44 |
October | 23.70 | 12.66 |
November | 22.71 | 8.91 |
December | 21.95 | 2.07 |
Annual Sum or Average | 23.29 | 13.21 |
Minimum of Months | 21.75 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F7 NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 22.00 | 8.00 |
April | 22.93 | 13.18 |
May | 23.89 | 18.32 |
June | 24.35 | 22.93 |
July | 24.41 | 25.34 |
August | 24.35 | 24.28 |
September | 24.18 | 20.44 |
October | 22.94 | 12.66 |
November | 21.84 | 8.91 |
December | 21.75 | 2.07 |
Annual Sum or Average | 23.01 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.41 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F7 N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 22.04 | 8.00 |
April | 22.96 | 13.18 |
May | 23.92 | 18.32 |
June | 24.33 | 22.93 |
July | 24.40 | 25.34 |
August | 24.35 | 24.28 |
September | 24.16 | 20.44 |
October | 23.06 | 12.66 |
November | 21.92 | 8.91 |
December | 21.77 | 2.07 |
Annual Sum or Average | 23.03 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F7 N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 22.04 | 8.00 |
April | 22.95 | 13.18 |
May | 23.91 | 18.32 |
June | 24.33 | 22.93 |
July | 24.40 | 25.34 |
August | 24.35 | 24.28 |
September | 24.16 | 20.44 |
October | 23.05 | 12.66 |
November | 21.92 | 8.91 |
December | 21.77 | 2.07 |
Annual Sum or Average | 23.03 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F7 S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.85 | -0.5 |
February | 21.98 | 2.24 |
March | 22.75 | 8.00 |
April | 23.64 | 13.18 |
May | 24.07 | 18.32 |
June | 24.34 | 22.93 |
July | 24.40 | 25.34 |
August | 24.37 | 24.28 |
September | 24.31 | 20.44 |
October | 23.88 | 12.66 |
November | 23.14 | 8.91 |
December | 22.13 | 2.07 |
Annual Sum or Average | 23.41 | 13.21 |
Minimum of Months | 21.85 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F7 S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.85 | -0.5 |
February | 21.98 | 2.24 |
March | 22.75 | 8.00 |
April | 23.64 | 13.18 |
May | 24.07 | 18.32 |
June | 24.34 | 22.93 |
July | 24.40 | 25.34 |
August | 24.37 | 24.28 |
September | 24.31 | 20.44 |
October | 23.88 | 12.66 |
November | 23.14 | 8.91 |
December | 22.13 | 2.07 |
Annual Sum or Average | 23.41 | 13.21 |
Minimum of Months | 21.85 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F7 CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.73 | -0.5 |
February | 22.01 | 2.24 |
March | 23.14 | 8.00 |
April | 24.56 | 13.18 |
May | 25.64 | 18.32 |
June | 26.43 | 22.93 |
July | 26.65 | 25.34 |
August | 26.54 | 24.28 |
September | 26.05 | 20.44 |
October | 24.69 | 12.66 |
November | 23.29 | 8.91 |
December | 22.07 | 2.07 |
Annual Sum or Average | 24.41 | 13.21 |
Minimum of Months | 21.73 | -0.5 |
Maximum of Months | 26.65 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F8 SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.75 | -0.5 |
February | 21.85 | 2.24 |
March | 22.45 | 8.00 |
April | 23.44 | 13.18 |
May | 24.00 | 18.32 |
June | 24.34 | 22.93 |
July | 24.40 | 25.34 |
August | 24.37 | 24.28 |
September | 24.29 | 20.44 |
October | 23.67 | 12.66 |
November | 22.70 | 8.91 |
December | 21.96 | 2.07 |
Annual Sum or Average | 23.28 | 13.21 |
Minimum of Months | 21.75 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F8 NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 22.03 | 8.00 |
April | 22.95 | 13.18 |
May | 23.90 | 18.32 |
June | 24.34 | 22.93 |
July | 24.40 | 25.34 |
August | 24.35 | 24.28 |
September | 24.17 | 20.44 |
October | 22.98 | 12.66 |
November | 21.89 | 8.91 |
December | 21.76 | 2.07 |
Annual Sum or Average | 23.02 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F8 SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.74 | -0.5 |
February | 21.84 | 2.24 |
March | 22.45 | 8.00 |
April | 23.40 | 13.18 |
May | 23.99 | 18.32 |
June | 24.35 | 22.93 |
July | 24.40 | 25.34 |
August | 24.37 | 24.28 |
September | 24.29 | 20.44 |
October | 23.66 | 12.66 |
November | 22.64 | 8.91 |
December | 21.92 | 2.07 |
Annual Sum or Average | 23.26 | 13.21 |
Minimum of Months | 21.74 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F8 NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.70 | 2.24 |
March | 21.99 | 8.00 |
April | 22.84 | 13.18 |
May | 23.84 | 18.32 |
June | 24.35 | 22.93 |
July | 24.41 | 25.34 |
August | 24.35 | 24.28 |
September | 24.15 | 20.44 |
October | 22.88 | 12.66 |
November | 21.83 | 8.91 |
December | 21.74 | 2.07 |
Annual Sum or Average | 22.99 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.41 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F8 N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 22.02 | 8.00 |
April | 22.88 | 13.18 |
May | 23.87 | 18.32 |
June | 24.33 | 22.93 |
July | 24.40 | 25.34 |
August | 24.35 | 24.28 |
September | 24.14 | 20.44 |
October | 22.99 | 12.66 |
November | 21.89 | 8.91 |
December | 21.76 | 2.07 |
Annual Sum or Average | 23.01 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F8 N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 22.02 | 8.00 |
April | 22.87 | 13.18 |
May | 23.86 | 18.32 |
June | 24.33 | 22.93 |
July | 24.40 | 25.34 |
August | 24.35 | 24.28 |
September | 24.14 | 20.44 |
October | 22.98 | 12.66 |
November | 21.89 | 8.91 |
December | 21.76 | 2.07 |
Annual Sum or Average | 23.01 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F8 S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.83 | -0.5 |
February | 21.95 | 2.24 |
March | 22.68 | 8.00 |
April | 23.55 | 13.18 |
May | 24.03 | 18.32 |
June | 24.34 | 22.93 |
July | 24.40 | 25.34 |
August | 24.37 | 24.28 |
September | 24.30 | 20.44 |
October | 23.84 | 12.66 |
November | 23.05 | 8.91 |
December | 22.09 | 2.07 |
Annual Sum or Average | 23.38 | 13.21 |
Minimum of Months | 21.83 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F8 S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.83 | -0.5 |
February | 21.95 | 2.24 |
March | 22.68 | 8.00 |
April | 23.55 | 13.18 |
May | 24.03 | 18.32 |
June | 24.34 | 22.93 |
July | 24.40 | 25.34 |
August | 24.37 | 24.28 |
September | 24.30 | 20.44 |
October | 23.84 | 12.66 |
November | 23.05 | 8.91 |
December | 22.09 | 2.07 |
Annual Sum or Average | 23.38 | 13.21 |
Minimum of Months | 21.83 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F8 CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.64 | -0.5 |
February | 21.92 | 2.24 |
March | 23.05 | 8.00 |
April | 24.45 | 13.18 |
May | 25.58 | 18.32 |
June | 26.42 | 22.93 |
July | 26.65 | 25.34 |
August | 26.54 | 24.28 |
September | 26.02 | 20.44 |
October | 24.59 | 12.66 |
November | 23.19 | 8.91 |
December | 21.98 | 2.07 |
Annual Sum or Average | 24.35 | 13.21 |
Minimum of Months | 21.64 | -0.5 |
Maximum of Months | 26.65 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F9 SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.74 | -0.5 |
February | 21.83 | 2.24 |
March | 22.40 | 8.00 |
April | 23.35 | 13.18 |
May | 23.96 | 18.32 |
June | 24.34 | 22.93 |
July | 24.40 | 25.34 |
August | 24.37 | 24.28 |
September | 24.28 | 20.44 |
October | 23.61 | 12.66 |
November | 22.60 | 8.91 |
December | 21.94 | 2.07 |
Annual Sum or Average | 23.24 | 13.21 |
Minimum of Months | 21.74 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F9 NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 22.02 | 8.00 |
April | 22.88 | 13.18 |
May | 23.85 | 18.32 |
June | 24.33 | 22.93 |
July | 24.40 | 25.34 |
August | 24.35 | 24.28 |
September | 24.15 | 20.44 |
October | 22.93 | 12.66 |
November | 21.87 | 8.91 |
December | 21.75 | 2.07 |
Annual Sum or Average | 23.00 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F9 SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.73 | -0.5 |
February | 21.82 | 2.24 |
March | 22.40 | 8.00 |
April | 23.32 | 13.18 |
May | 23.95 | 18.32 |
June | 24.35 | 22.93 |
July | 24.40 | 25.34 |
August | 24.37 | 24.28 |
September | 24.28 | 20.44 |
October | 23.59 | 12.66 |
November | 22.54 | 8.91 |
December | 21.90 | 2.07 |
Annual Sum or Average | 23.23 | 13.21 |
Minimum of Months | 21.73 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F9 NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.70 | 2.24 |
March | 21.98 | 8.00 |
April | 22.77 | 13.18 |
May | 23.79 | 18.32 |
June | 24.34 | 22.93 |
July | 24.41 | 25.34 |
August | 24.35 | 24.28 |
September | 24.13 | 20.44 |
October | 22.81 | 12.66 |
November | 21.81 | 8.91 |
December | 21.74 | 2.07 |
Annual Sum or Average | 22.97 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.41 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F9 N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 22.01 | 8.00 |
April | 22.82 | 13.18 |
May | 23.82 | 18.32 |
June | 24.32 | 22.93 |
July | 24.40 | 25.34 |
August | 24.34 | 24.28 |
September | 24.12 | 20.44 |
October | 22.92 | 12.66 |
November | 21.87 | 8.91 |
December | 21.76 | 2.07 |
Annual Sum or Average | 22.99 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F9 N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 22.01 | 8.00 |
April | 22.81 | 13.18 |
May | 23.82 | 18.32 |
June | 24.32 | 22.93 |
July | 24.40 | 25.34 |
August | 24.34 | 24.28 |
September | 24.12 | 20.44 |
October | 22.91 | 12.66 |
November | 21.87 | 8.91 |
December | 21.76 | 2.07 |
Annual Sum or Average | 22.99 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F9 S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.81 | -0.5 |
February | 21.92 | 2.24 |
March | 22.60 | 8.00 |
April | 23.46 | 13.18 |
May | 23.99 | 18.32 |
June | 24.33 | 22.93 |
July | 24.40 | 25.34 |
August | 24.37 | 24.28 |
September | 24.28 | 20.44 |
October | 23.78 | 12.66 |
November | 22.91 | 8.91 |
December | 22.04 | 2.07 |
Annual Sum or Average | 23.33 | 13.21 |
Minimum of Months | 21.81 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F9 S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.81 | -0.5 |
February | 21.92 | 2.24 |
March | 22.60 | 8.00 |
April | 23.46 | 13.18 |
May | 23.99 | 18.32 |
June | 24.33 | 22.93 |
July | 24.40 | 25.34 |
August | 24.37 | 24.28 |
September | 24.28 | 20.44 |
October | 23.78 | 12.66 |
November | 22.91 | 8.91 |
December | 22.04 | 2.07 |
Annual Sum or Average | 23.33 | 13.21 |
Minimum of Months | 21.81 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: F9 CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.46 | -0.5 |
February | 21.77 | 2.24 |
March | 22.93 | 8.00 |
April | 24.35 | 13.18 |
May | 25.56 | 18.32 |
June | 26.49 | 22.93 |
July | 26.74 | 25.34 |
August | 26.62 | 24.28 |
September | 26.03 | 20.44 |
October | 24.47 | 12.66 |
November | 23.03 | 8.91 |
December | 21.81 | 2.07 |
Annual Sum or Average | 24.28 | 13.21 |
Minimum of Months | 21.46 | -0.5 |
Maximum of Months | 26.74 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.78 | -0.5 |
February | 21.86 | 2.24 |
March | 22.39 | 8.00 |
April | 23.11 | 13.18 |
May | 23.80 | 18.32 |
June | 24.29 | 22.93 |
July | 24.39 | 25.34 |
August | 24.35 | 24.28 |
September | 24.16 | 20.44 |
October | 23.31 | 12.66 |
November | 22.44 | 8.91 |
December | 21.94 | 2.07 |
Annual Sum or Average | 23.16 | 13.21 |
Minimum of Months | 21.78 | -0.5 |
Maximum of Months | 24.39 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.73 | 2.24 |
March | 22.06 | 8.00 |
April | 22.77 | 13.18 |
May | 23.71 | 18.32 |
June | 24.28 | 22.93 |
July | 24.39 | 25.34 |
August | 24.33 | 24.28 |
September | 24.03 | 20.44 |
October | 22.79 | 12.66 |
November | 21.90 | 8.91 |
December | 21.76 | 2.07 |
Annual Sum or Average | 22.96 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.39 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.76 | -0.5 |
February | 21.85 | 2.24 |
March | 22.39 | 8.00 |
April | 23.09 | 13.18 |
May | 23.80 | 18.32 |
June | 24.30 | 22.93 |
July | 24.39 | 25.34 |
August | 24.36 | 24.28 |
September | 24.16 | 20.44 |
October | 23.29 | 12.66 |
November | 22.39 | 8.91 |
December | 21.90 | 2.07 |
Annual Sum or Average | 23.15 | 13.21 |
Minimum of Months | 21.76 | -0.5 |
Maximum of Months | 24.39 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 22.01 | 8.00 |
April | 22.69 | 13.18 |
May | 23.65 | 18.32 |
June | 24.29 | 22.93 |
July | 24.40 | 25.34 |
August | 24.33 | 24.28 |
September | 24.00 | 20.44 |
October | 22.69 | 12.66 |
November | 21.83 | 8.91 |
December | 21.75 | 2.07 |
Annual Sum or Average | 22.93 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.40 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.72 | 2.24 |
March | 22.03 | 8.00 |
April | 22.72 | 13.18 |
May | 23.68 | 18.32 |
June | 24.28 | 22.93 |
July | 24.39 | 25.34 |
August | 24.32 | 24.28 |
September | 24.00 | 20.44 |
October | 22.76 | 12.66 |
November | 21.88 | 8.91 |
December | 21.76 | 2.07 |
Annual Sum or Average | 22.94 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.39 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -0.5 |
February | 21.71 | 2.24 |
March | 22.02 | 8.00 |
April | 22.71 | 13.18 |
May | 23.68 | 18.32 |
June | 24.28 | 22.93 |
July | 24.39 | 25.34 |
August | 24.32 | 24.28 |
September | 24.00 | 20.44 |
October | 22.76 | 12.66 |
November | 21.88 | 8.91 |
December | 21.76 | 2.07 |
Annual Sum or Average | 22.94 | 13.21 |
Minimum of Months | 21.70 | -0.5 |
Maximum of Months | 24.39 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.84 | -0.5 |
February | 21.94 | 2.24 |
March | 22.52 | 8.00 |
April | 23.26 | 13.18 |
May | 23.86 | 18.32 |
June | 24.29 | 22.93 |
July | 24.39 | 25.34 |
August | 24.35 | 24.28 |
September | 24.19 | 20.44 |
October | 23.49 | 12.66 |
November | 22.63 | 8.91 |
December | 22.02 | 2.07 |
Annual Sum or Average | 23.24 | 13.21 |
Minimum of Months | 21.84 | -0.5 |
Maximum of Months | 24.39 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.84 | -0.5 |
February | 21.94 | 2.24 |
March | 22.52 | 8.00 |
April | 23.26 | 13.18 |
May | 23.86 | 18.32 |
June | 24.29 | 22.93 |
July | 24.39 | 25.34 |
August | 24.35 | 24.28 |
September | 24.19 | 20.44 |
October | 23.49 | 12.66 |
November | 22.63 | 8.91 |
December | 22.02 | 2.07 |
Annual Sum or Average | 23.24 | 13.21 |
Minimum of Months | 21.84 | -0.5 |
Maximum of Months | 24.39 | 25.34 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2015-09-09 19:00:30
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.30 | -0.5 |
February | 21.76 | 2.24 |
March | 23.14 | 8.00 |
April | 24.75 | 13.18 |
May | 26.16 | 18.32 |
June | 27.29 | 22.93 |
July | 27.64 | 25.34 |
August | 27.44 | 24.28 |
September | 26.63 | 20.44 |
October | 24.69 | 12.66 |
November | 23.10 | 8.91 |
December | 21.72 | 2.07 |
Annual Sum or Average | 24.65 | 13.21 |
Minimum of Months | 21.30 | -0.5 |
Maximum of Months | 27.64 | 25.34 |
Report: COMPONENTS OF PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2015-09-09 19:00:30
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W] | |
January | 0.264514E+12 | 147188.560 | 08-JAN-18:00 | 13120.457 | 57042.023 | 20311.586 | 41987.630 | 0.000 | 10364.000 | 2374.854 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
February | 0.229198E+12 | 148491.633 | 13-FEB-18:15 | 13120.457 | 57042.023 | 20311.586 | 43290.901 | 0.000 | 10364.000 | 2374.854 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
March | 0.223347E+12 | 147631.448 | 28-MAR-18:30 | 14401.373 | 51749.961 | 20311.586 | 0.000 | 44767.518 | 10364.000 | 2374.854 | 1901.130 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
April | 0.199577E+12 | 138224.246 | 20-APR-16:15 | 11327.174 | 57142.088 | 20311.586 | 0.000 | 43434.836 | 0.000 | 2374.854 | 1638.511 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
May | 0.243415E+12 | 170189.078 | 31-MAY-17:15 | 13120.457 | 57042.023 | 20311.586 | 0.000 | 72241.595 | 0.000 | 2374.854 | 3110.751 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
June | 0.291479E+12 | 177460.713 | 29-JUN-17:15 | 13120.457 | 57042.023 | 20311.586 | 0.000 | 79427.675 | 0.000 | 2374.854 | 3196.306 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
July | 0.334872E+12 | 184413.147 | 09-JUL-17:15 | 13120.457 | 57042.023 | 20311.586 | 0.000 | 86042.262 | 0.000 | 2374.854 | 3534.152 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.320642E+12 | 182085.361 | 13-AUG-17:15 | 13120.457 | 57042.023 | 20311.586 | 0.000 | 83714.477 | 0.000 | 2374.854 | 3534.152 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.267507E+12 | 185618.298 | 03-SEP-18:45 | 14401.373 | 51749.961 | 20311.586 | 0.000 | 81177.050 | 10364.000 | 2374.854 | 3478.448 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
October | 0.222408E+12 | 157451.944 | 02-OCT-16:15 | 11327.174 | 57142.088 | 20311.586 | 0.000 | 61625.780 | 0.000 | 2374.854 | 2675.265 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
November | 0.210185E+12 | 117233.915 | 28-NOV-18:00 | 13120.457 | 57042.023 | 20311.586 | 12032.986 | 0.000 | 10364.000 | 2374.854 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
December | 0.252744E+12 | 150837.716 | 25-DEC-07:15 | 9533.891 | 40766.715 | 20311.586 | 66423.952 | 0.000 | 10364.000 | 2374.854 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.305989E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||||
Minimum of Months | 0.199577E+12 | 117233.915 | 9533.891 | 40766.715 | 20311.586 | 0.000 | 0.000 | 0.000 | 2374.854 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.334872E+12 | 185618.298 | 14401.373 | 57142.088 | 20311.586 | 66423.952 | 86042.262 | 10364.000 | 2374.854 | 3534.152 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: COMPONENTS OF PEAK GAS DEMAND
For: Meter
Timestamp: 2015-09-09 19:00:30
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC [Invalid/Undefined] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT {AT MAX/MIN} [W] | WATERSYSTEMS:GAS {AT MAX/MIN} [W] | WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.342124E+12 | 315433.752 | 18-JAN-06:30 | 0.000 | 0.000 | 0.000 | 315433.752 | 75830.898 | 75830.898 | 239602.854 |
February | 0.273207E+12 | 321611.666 | 13-FEB-08:45 | 0.000 | 0.000 | 0.000 | 321611.666 | 79597.547 | 79597.547 | 242014.118 |
March | 0.165887E+12 | 205258.191 | 06-MAR-06:30 | 0.000 | 0.000 | 0.000 | 205258.191 | 76142.720 | 76142.720 | 129115.471 |
April | 0.997442E+11 | 134035.743 | 17-APR-05:00 | 0.000 | 0.000 | 0.000 | 134035.743 | 76018.996 | 76018.996 | 58016.747 |
May | 0.926758E+11 | 76976.739 | 01-MAY-06:45 | 0.000 | 0.000 | 0.000 | 76976.739 | 76976.739 | 76976.739 | 0.000 |
June | 0.832971E+11 | 74447.474 | 01-JUN-06:30 | 0.000 | 0.000 | 0.000 | 74447.474 | 74447.474 | 74447.474 | 0.000 |
July | 0.816148E+11 | 72823.818 | 01-JUL-06:00 | 0.000 | 0.000 | 0.000 | 72823.818 | 72823.818 | 72823.818 | 0.000 |
August | 0.804831E+11 | 72130.467 | 31-AUG-06:45 | 0.000 | 0.000 | 0.000 | 72130.467 | 72130.467 | 72130.467 | 0.000 |
September | 0.803219E+11 | 73374.566 | 30-SEP-06:45 | 0.000 | 0.000 | 0.000 | 73374.566 | 73374.566 | 73374.566 | 0.000 |
October | 0.996434E+11 | 144611.220 | 27-OCT-06:30 | 0.000 | 0.000 | 0.000 | 144611.220 | 75048.804 | 75048.804 | 69562.416 |
November | 0.125267E+12 | 154329.351 | 29-NOV-06:00 | 0.000 | 0.000 | 0.000 | 154329.351 | 75740.574 | 75740.574 | 78588.777 |
December | 0.288706E+12 | 365692.463 | 25-DEC-07:15 | 0.000 | 0.000 | 0.000 | 365692.463 | 78213.158 | 78213.158 | 287479.305 |
Annual Sum or Average | 0.181297E+13 | 0.000 | 0.000 | 0.000 | ||||||
Minimum of Months | 0.803219E+11 | 72130.467 | 0.000 | 0.000 | 0.000 | 72130.467 | 72130.467 | 72130.467 | 0.000 | |
Maximum of Months | 0.342124E+12 | 365692.463 | 0.000 | 0.000 | 0.000 | 365692.463 | 79597.547 | 79597.547 | 287479.305 |