Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 19:11

Tabular Output Report in Format: HTML

Building: High-Rise Apartment

Environment: Salem Mcnary Field OR USA TMY3 WMO#=726940

Simulation Timestamp: 2015-09-09 19:12:13


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:13

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 4377.59 558.62 620.06
Net Site Energy 4377.59 558.62 620.06
Total Source Energy 10463.19 1335.19 1482.06
Net Source Energy 10463.19 1335.19 1482.06


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 7836.48
Net Conditioned Building Area 7059.89
Unconditioned Building Area 776.58


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 143.57 483.12 0.00 0.00 0.00 0.00
Cooling 235.55 0.00 0.00 0.00 0.00 0.00
Interior Lighting 296.56 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 162.79 0.00 0.00 0.00 0.00 0.00
Interior Equipment 1137.32 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 662.42 0.00 0.00 0.00 0.00 0.00
Pumps 61.04 0.00 0.00 0.00 0.00 0.00
Heat Rejection 9.60 0.00 0.00 0.00 0.00 746.40
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 1149.45 0.00 0.00 0.00 4778.51
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 2745.02 1632.57 0.00 0.00 0.00 5524.92
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating Boiler 0.00 483.12 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
  Other 143.57 0.00 0.00 0.00 0.00 0.00
Cooling General 235.55 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 242.55 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 54.01 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 162.79 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 1137.32 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 662.42 0.00 0.00 0.00 0.00 0.00
Pumps General 61.04 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 9.60 0.00 0.00 0.00 0.00 746.40
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 1149.45 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 4778.51
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 65.07 0.00 0.00 0.00 0.00 0.00
HVAC 157.53 231.25 0.00 0.00 0.00 0.78
Other 161.10 0.00 0.00 0.00 0.00 0.00
Total 388.82 231.25 0.00 0.00 0.00 0.78


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 58.62 0.00 0.00 0.00 0.00 0.00
HVAC 141.92 208.33 0.00 0.00 0.00 0.71
Other 145.13 0.00 0.00 0.00 0.00 0.00
Total 350.29 208.33 0.00 0.00 0.00 0.71


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 2745.02 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 2745.02 100.00
     
Total On-Site and Utility Electric Sources 2745.02 100.00
Total Electricity End Uses 2745.02 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 5524.92 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 5524.92 100.00
Total Water End Uses 5524.92 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 155.00
Time Setpoint Not Met During Occupied Cooling 86.75
Time Not Comfortable Based on Simple ASHRAE 55-2004 449.25


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |

COMPONENTS OF PEAK ELECTRICAL DEMAND

| Meter |

COMPONENTS OF PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:13

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 19:11
RunPeriod Salem Mcnary Field OR USA TMY3 WMO#=726940
Weather File Salem Mcnary Field OR USA TMY3 WMO#=726940
Latitude [deg] 44.90
Longitude [deg] -123.0
Elevation [m] 60.00
Time Zone -8.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3855.02 1411.96 515.55 1411.96 515.55
Window Opening Area [m2] 1150.39 423.59 152.73 423.59 150.48
Window-Wall Ratio [%] 29.84 30.00 29.62 30.00 29.19


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3752.84 1411.96 464.46 1411.96 464.46
Window Opening Area [m2] 1125.85 423.59 139.34 423.59 139.34
Window-Wall Ratio [%] 30.00 30.00 30.00 30.00 30.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
OFFICE 88.25 Yes Yes 268.96 1.00 58.52 17.56 29.5362 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 4.47 6.7128   0.0000
F2 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F3 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F4 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
M SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
M CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 13.4255   0.0000
F6 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F7 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F8 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F9 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
T SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   264.3872
Total 7836.48     23884.04   3855.02 1150.39 4.3335 39.48 8.6291
Conditioned Total 7059.89     21517.16   3752.84 1125.85 3.9979 35.57 6.6700
Unconditioned Total 776.58     2366.87   102.18 24.54 7.3840   26.4387
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:13

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 19-JUL-17:15 20-DEC-07:00 - - - 17-JUL-17:15
Heating 0.00 179384.52 0.00 0.00 0.00 0.00
Cooling 67773.43 0.00 0.00 0.00 0.00 0.00
Interior Lighting 13120.46 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 57042.02 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 21005.32 0.00 0.00 0.00 0.00 0.00
Pumps 1959.84 0.00 0.00 0.00 0.00 0.00
Heat Rejection 2573.63 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 78981.47 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 165462.52 258366.00 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating Boiler 0.00 179384.52 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 67773.43 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 10541.04 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 2579.42 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 57042.02 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 21005.32 0.00 0.00 0.00 0.00 0.00
Pumps General 1959.84 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 2573.63 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 78981.47 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:13

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 454.67 523.70 0.00 0.00 0.00
Cooling 745.98 0.00 0.00 0.00 0.00
Interior Lighting 939.20 0.00 0.00 0.00 0.00
Exterior Lighting 515.57 0.00 0.00 0.00 0.00
Interior Equipment 3601.91 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 2097.90 0.00 0.00 0.00 0.00
Pumps 193.30 0.00 0.00 0.00 0.00
Heat Rejection 30.40 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 1246.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 8693.48 1769.70 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 64.40 74.18 0.00 0.00 0.00
Cooling 105.66 0.00 0.00 0.00 0.00
Interior Lighting 133.03 0.00 0.00 0.00 0.00
Exterior Lighting 73.03 0.00 0.00 0.00 0.00
Interior Equipment 510.19 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 297.16 0.00 0.00 0.00 0.00
Pumps 27.38 0.00 0.00 0.00 0.00
Heat Rejection 4.31 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 176.49 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1231.39 250.67 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 64.40 74.18 0.00 0.00 0.00
Cooling 105.66 0.00 0.00 0.00 0.00
Interior Lighting 133.03 0.00 0.00 0.00 0.00
Exterior Lighting 73.03 0.00 0.00 0.00 0.00
Interior Equipment 510.19 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 297.16 0.00 0.00 0.00 0.00
Pumps 27.38 0.00 0.00 0.00 0.00
Heat Rejection 4.31 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 176.49 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1231.39 250.67 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:13

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB -5.60 0.00 -5.60 Wetbulb [C] 2.10 0.00
SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 33.30 15.40 19.40 Wetbulb [C] 4.30 0.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:13

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 270.00 180.00  
F2 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F2 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F2 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F2 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F2 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F2 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F3 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F3 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F3 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F3 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F3 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F3 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F4 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F4 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F4 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F4 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F4 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F4 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
M WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F6 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F6 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F6 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F6 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F6 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F6 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F7 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F7 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F7 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F7 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F7 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F7 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F8 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F8 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F8 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F8 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F8 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F8 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F9 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F9 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F9 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F9 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F9 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F9 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.30 0.269 0.283 77.66 0.00 0.00  


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL SWA 180.00 90.00 S
GWINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G WWALL SWA 270.00 90.00 W
GWINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL NWA 0.00 90.00 N
GWINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G WWALL NWA 270.00 90.00 W
GWINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL SEA 180.00 90.00 S
GWINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G EWALL SEA 90.00 90.00 E
GWINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL NEA 0.00 90.00 N
GWINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G EWALL NEA 90.00 90.00 E
GWINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL N1A 0.00 90.00 N
GWINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL N2A 0.00 90.00 N
GWINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL S1A 180.00 90.00 S
GWINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL S2A 180.00 90.00 S
GWINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No G WWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.48_SHGC_0.40 3.36 0.00 0.00 3.36 3.36 2.653 0.426 0.308     No G EWALL C 90.00 90.00 E
F2WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 WWALL SWA 270.00 90.00 W
F2WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL SWA 180.00 90.00 S
F2WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL NWA 0.00 90.00 N
F2WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 WWALL NWA 270.00 90.00 W
F2WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 EWALL SEA 90.00 90.00 E
F2WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL SEA 180.00 90.00 S
F2WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL NEA 0.00 90.00 N
F2WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 EWALL NEA 90.00 90.00 E
F2WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL N1A 0.00 90.00 N
F2WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL N2A 0.00 90.00 N
F2WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL S1A 180.00 90.00 S
F2WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL S2A 180.00 90.00 S
F2WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F2 WWALL C 270.00 90.00 W
F2WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F2 EWALL C 90.00 90.00 E
F3WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 WWALL SWA 270.00 90.00 W
F3WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL SWA 180.00 90.00 S
F3WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL NWA 0.00 90.00 N
F3WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 WWALL NWA 270.00 90.00 W
F3WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 EWALL SEA 90.00 90.00 E
F3WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL SEA 180.00 90.00 S
F3WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL NEA 0.00 90.00 N
F3WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 EWALL NEA 90.00 90.00 E
F3WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL N1A 0.00 90.00 N
F3WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL N2A 0.00 90.00 N
F3WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL S1A 180.00 90.00 S
F3WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL S2A 180.00 90.00 S
F3WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F3 WWALL C 270.00 90.00 W
F3WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F3 EWALL C 90.00 90.00 E
F4WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 WWALL SWA 270.00 90.00 W
F4WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL SWA 180.00 90.00 S
F4WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL NWA 0.00 90.00 N
F4WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 WWALL NWA 270.00 90.00 W
F4WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 EWALL SEA 90.00 90.00 E
F4WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL SEA 180.00 90.00 S
F4WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL NEA 0.00 90.00 N
F4WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 EWALL NEA 90.00 90.00 E
F4WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL N1A 0.00 90.00 N
F4WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL N2A 0.00 90.00 N
F4WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL S1A 180.00 90.00 S
F4WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL S2A 180.00 90.00 S
F4WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F4 WWALL C 270.00 90.00 W
F4WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F4 EWALL C 90.00 90.00 E
MWINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M WWALL SWA 270.00 90.00 W
MWINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL SWA 180.00 90.00 S
MWINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL NWA 0.00 90.00 N
MWINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M WWALL NWA 270.00 90.00 W
MWINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M EWALL SEA 90.00 90.00 E
MWINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL SEA 180.00 90.00 S
MWINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL NEA 0.00 90.00 N
MWINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M EWALL NEA 90.00 90.00 E
MWINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL N1A 0.00 90.00 N
MWINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL N2A 0.00 90.00 N
MWINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL S1A 180.00 90.00 S
MWINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL S2A 180.00 90.00 S
MWINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No M WWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No M EWALL C 90.00 90.00 E
F6WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 WWALL SWA 270.00 90.00 W
F6WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL SWA 180.00 90.00 S
F6WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL NWA 0.00 90.00 N
F6WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 WWALL NWA 270.00 90.00 W
F6WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 EWALL SEA 90.00 90.00 E
F6WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL SEA 180.00 90.00 S
F6WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL NEA 0.00 90.00 N
F6WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 EWALL NEA 90.00 90.00 E
F6WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL N1A 0.00 90.00 N
F6WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL N2A 0.00 90.00 N
F6WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL S1A 180.00 90.00 S
F6WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL S2A 180.00 90.00 S
F6WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F6 WWALL C 270.00 90.00 W
F6WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F6 EWALL C 90.00 90.00 E
F7WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 WWALL SWA 270.00 90.00 W
F7WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL SWA 180.00 90.00 S
F7WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL NWA 0.00 90.00 N
F7WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 WWALL NWA 270.00 90.00 W
F7WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 EWALL SEA 90.00 90.00 E
F7WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL SEA 180.00 90.00 S
F7WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL NEA 0.00 90.00 N
F7WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 EWALL NEA 90.00 90.00 E
F7WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL N1A 0.00 90.00 N
F7WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL N2A 0.00 90.00 N
F7WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL S1A 180.00 90.00 S
F7WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL S2A 180.00 90.00 S
F7WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F7 WWALL C 270.00 90.00 W
F7WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F7 EWALL C 90.00 90.00 E
F8WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 WWALL SWA 270.00 90.00 W
F8WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL SWA 180.00 90.00 S
F8WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL NWA 0.00 90.00 N
F8WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 WWALL NWA 270.00 90.00 W
F8WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 EWALL SEA 90.00 90.00 E
F8WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL SEA 180.00 90.00 S
F8WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL NEA 0.00 90.00 N
F8WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 EWALL NEA 90.00 90.00 E
F8WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL N1A 0.00 90.00 N
F8WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL N2A 0.00 90.00 N
F8WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL S1A 180.00 90.00 S
F8WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL S2A 180.00 90.00 S
F8WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F8 WWALL C 270.00 90.00 W
F8WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F8 EWALL C 90.00 90.00 E
F9WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 WWALL SWA 270.00 90.00 W
F9WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL SWA 180.00 90.00 S
F9WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL NWA 0.00 90.00 N
F9WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 WWALL NWA 270.00 90.00 W
F9WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 EWALL SEA 90.00 90.00 E
F9WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL SEA 180.00 90.00 S
F9WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL NEA 0.00 90.00 N
F9WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 EWALL NEA 90.00 90.00 E
F9WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL N1A 0.00 90.00 N
F9WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL N2A 0.00 90.00 N
F9WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL S1A 180.00 90.00 S
F9WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL S2A 180.00 90.00 S
F9WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F9 WWALL C 270.00 90.00 W
F9WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F9 EWALL C 90.00 90.00 E
TWINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T WWALL SWA 270.00 90.00 W
TWINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL SWA 180.00 90.00 S
TWINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL NWA 0.00 90.00 N
TWINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T WWALL NWA 270.00 90.00 W
TWINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T EWALL SEA 90.00 90.00 E
TWINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL SEA 180.00 90.00 S
TWINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL NEA 0.00 90.00 N
TWINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T EWALL NEA 90.00 90.00 E
TWINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL N1A 0.00 90.00 N
TWINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL N2A 0.00 90.00 N
TWINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL S1A 180.00 90.00 S
TWINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL S2A 180.00 90.00 S
TWINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No T WWALL C 270.00 90.00 W
TWINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No T EWALL C 90.00 90.00 E
Total or Average           1150.39 2.653 0.426 0.308              
North Total or Average           423.59 2.653 0.426 0.308              
Non-North Total or Average           726.80 2.653 0.426 0.308              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:13

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:13

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
G SW APARTMENT_LIGHTS_HARDWIRED G SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G NW APARTMENT_LIGHTS_HARDWIRED G NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
OFFICE_LIGHTS_HARDWIRED OFFICE 14.7681 88.25 1303.26 GeneralLights LTG_OFF_SCH 62.05 168.00 61.07 0.0000 Y 14.94
G NE APARTMENT_LIGHTS_HARDWIRED G NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G N1 APARTMENT_LIGHTS_HARDWIRED G N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G N2 APARTMENT_LIGHTS_HARDWIRED G N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G S1 APARTMENT_LIGHTS_HARDWIRED G S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G S2 APARTMENT_LIGHTS_HARDWIRED G S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G CORRIDOR_LIGHTS_HARDWIRED G CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F2 SW APARTMENT_LIGHTS_HARDWIRED F2 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 NW APARTMENT_LIGHTS_HARDWIRED F2 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 SE APARTMENT_LIGHTS_HARDWIRED F2 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 NE APARTMENT_LIGHTS_HARDWIRED F2 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 N1 APARTMENT_LIGHTS_HARDWIRED F2 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 N2 APARTMENT_LIGHTS_HARDWIRED F2 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 S1 APARTMENT_LIGHTS_HARDWIRED F2 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 S2 APARTMENT_LIGHTS_HARDWIRED F2 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 CORRIDOR_LIGHTS_HARDWIRED F2 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F3 SW APARTMENT_LIGHTS_HARDWIRED F3 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 NW APARTMENT_LIGHTS_HARDWIRED F3 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 SE APARTMENT_LIGHTS_HARDWIRED F3 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 NE APARTMENT_LIGHTS_HARDWIRED F3 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 N1 APARTMENT_LIGHTS_HARDWIRED F3 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 N2 APARTMENT_LIGHTS_HARDWIRED F3 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 S1 APARTMENT_LIGHTS_HARDWIRED F3 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 S2 APARTMENT_LIGHTS_HARDWIRED F3 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 CORRIDOR_LIGHTS_HARDWIRED F3 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F4 SW APARTMENT_LIGHTS_HARDWIRED F4 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 NW APARTMENT_LIGHTS_HARDWIRED F4 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 SE APARTMENT_LIGHTS_HARDWIRED F4 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 NE APARTMENT_LIGHTS_HARDWIRED F4 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 N1 APARTMENT_LIGHTS_HARDWIRED F4 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 N2 APARTMENT_LIGHTS_HARDWIRED F4 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 S1 APARTMENT_LIGHTS_HARDWIRED F4 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 S2 APARTMENT_LIGHTS_HARDWIRED F4 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 CORRIDOR_LIGHTS_HARDWIRED F4 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
M SW APARTMENT_LIGHTS_HARDWIRED M SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M NW APARTMENT_LIGHTS_HARDWIRED M NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M SE APARTMENT_LIGHTS_HARDWIRED M SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M NE APARTMENT_LIGHTS_HARDWIRED M NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M N1 APARTMENT_LIGHTS_HARDWIRED M N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M N2 APARTMENT_LIGHTS_HARDWIRED M N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M S1 APARTMENT_LIGHTS_HARDWIRED M S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M S2 APARTMENT_LIGHTS_HARDWIRED M S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M CORRIDOR_LIGHTS_HARDWIRED M CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F6 SW APARTMENT_LIGHTS_HARDWIRED F6 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 NW APARTMENT_LIGHTS_HARDWIRED F6 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 SE APARTMENT_LIGHTS_HARDWIRED F6 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 NE APARTMENT_LIGHTS_HARDWIRED F6 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 N1 APARTMENT_LIGHTS_HARDWIRED F6 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 N2 APARTMENT_LIGHTS_HARDWIRED F6 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 S1 APARTMENT_LIGHTS_HARDWIRED F6 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 S2 APARTMENT_LIGHTS_HARDWIRED F6 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 CORRIDOR_LIGHTS_HARDWIRED F6 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F7 SW APARTMENT_LIGHTS_HARDWIRED F7 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 NW APARTMENT_LIGHTS_HARDWIRED F7 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 SE APARTMENT_LIGHTS_HARDWIRED F7 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 NE APARTMENT_LIGHTS_HARDWIRED F7 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 N1 APARTMENT_LIGHTS_HARDWIRED F7 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 N2 APARTMENT_LIGHTS_HARDWIRED F7 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 S1 APARTMENT_LIGHTS_HARDWIRED F7 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 S2 APARTMENT_LIGHTS_HARDWIRED F7 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 CORRIDOR_LIGHTS_HARDWIRED F7 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F8 SW APARTMENT_LIGHTS_HARDWIRED F8 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 NW APARTMENT_LIGHTS_HARDWIRED F8 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 SE APARTMENT_LIGHTS_HARDWIRED F8 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 NE APARTMENT_LIGHTS_HARDWIRED F8 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 N1 APARTMENT_LIGHTS_HARDWIRED F8 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 N2 APARTMENT_LIGHTS_HARDWIRED F8 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 S1 APARTMENT_LIGHTS_HARDWIRED F8 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 S2 APARTMENT_LIGHTS_HARDWIRED F8 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 CORRIDOR_LIGHTS_HARDWIRED F8 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F9 SW APARTMENT_LIGHTS_HARDWIRED F9 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 NW APARTMENT_LIGHTS_HARDWIRED F9 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 SE APARTMENT_LIGHTS_HARDWIRED F9 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 NE APARTMENT_LIGHTS_HARDWIRED F9 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 N1 APARTMENT_LIGHTS_HARDWIRED F9 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 N2 APARTMENT_LIGHTS_HARDWIRED F9 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 S1 APARTMENT_LIGHTS_HARDWIRED F9 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 S2 APARTMENT_LIGHTS_HARDWIRED F9 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 CORRIDOR_LIGHTS_HARDWIRED F9 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
T SW APARTMENT_LIGHTS_HARDWIRED T SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T NW APARTMENT_LIGHTS_HARDWIRED T NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T SE APARTMENT_LIGHTS_HARDWIRED T SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T NE APARTMENT_LIGHTS_HARDWIRED T NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T N1 APARTMENT_LIGHTS_HARDWIRED T N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T N2 APARTMENT_LIGHTS_HARDWIRED T N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T S1 APARTMENT_LIGHTS_HARDWIRED T S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T S2 APARTMENT_LIGHTS_HARDWIRED T S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T CORRIDOR_LIGHTS_HARDWIRED T CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
G SW APARTMENT_LIGHTS_PLUGIN G SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G NW APARTMENT_LIGHTS_PLUGIN G NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
OFFICE_LIGHTS_PLUGIN OFFICE 14.7681 88.25 1303.26 GeneralLights-plugin LTG_OFF_SCH 62.05 168.00 61.07 0.0000 Y 14.94
G NE APARTMENT_LIGHTS_PLUGIN G NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G N1 APARTMENT_LIGHTS_PLUGIN G N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G N2 APARTMENT_LIGHTS_PLUGIN G N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G S1 APARTMENT_LIGHTS_PLUGIN G S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G S2 APARTMENT_LIGHTS_PLUGIN G S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 SW APARTMENT_LIGHTS_PLUGIN F2 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 NW APARTMENT_LIGHTS_PLUGIN F2 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 SE APARTMENT_LIGHTS_PLUGIN F2 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 NE APARTMENT_LIGHTS_PLUGIN F2 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 N1 APARTMENT_LIGHTS_PLUGIN F2 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 N2 APARTMENT_LIGHTS_PLUGIN F2 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 S1 APARTMENT_LIGHTS_PLUGIN F2 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 S2 APARTMENT_LIGHTS_PLUGIN F2 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 SW APARTMENT_LIGHTS_PLUGIN F3 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 NW APARTMENT_LIGHTS_PLUGIN F3 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 SE APARTMENT_LIGHTS_PLUGIN F3 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 NE APARTMENT_LIGHTS_PLUGIN F3 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 N1 APARTMENT_LIGHTS_PLUGIN F3 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 N2 APARTMENT_LIGHTS_PLUGIN F3 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 S1 APARTMENT_LIGHTS_PLUGIN F3 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 S2 APARTMENT_LIGHTS_PLUGIN F3 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 SW APARTMENT_LIGHTS_PLUGIN F4 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 NW APARTMENT_LIGHTS_PLUGIN F4 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 SE APARTMENT_LIGHTS_PLUGIN F4 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 NE APARTMENT_LIGHTS_PLUGIN F4 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 N1 APARTMENT_LIGHTS_PLUGIN F4 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 N2 APARTMENT_LIGHTS_PLUGIN F4 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 S1 APARTMENT_LIGHTS_PLUGIN F4 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 S2 APARTMENT_LIGHTS_PLUGIN F4 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M SW APARTMENT_LIGHTS_PLUGIN M SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M NW APARTMENT_LIGHTS_PLUGIN M NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M SE APARTMENT_LIGHTS_PLUGIN M SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M NE APARTMENT_LIGHTS_PLUGIN M NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M N1 APARTMENT_LIGHTS_PLUGIN M N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M N2 APARTMENT_LIGHTS_PLUGIN M N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M S1 APARTMENT_LIGHTS_PLUGIN M S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M S2 APARTMENT_LIGHTS_PLUGIN M S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M CORRIDOR_LIGHTS_PLUGIN M CORRIDOR 6.7128 77.66 521.30 GeneralLights-plugin LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F6 SW APARTMENT_LIGHTS_PLUGIN F6 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 NW APARTMENT_LIGHTS_PLUGIN F6 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 SE APARTMENT_LIGHTS_PLUGIN F6 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 NE APARTMENT_LIGHTS_PLUGIN F6 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 N1 APARTMENT_LIGHTS_PLUGIN F6 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 N2 APARTMENT_LIGHTS_PLUGIN F6 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 S1 APARTMENT_LIGHTS_PLUGIN F6 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 S2 APARTMENT_LIGHTS_PLUGIN F6 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 SW APARTMENT_LIGHTS_PLUGIN F7 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 NW APARTMENT_LIGHTS_PLUGIN F7 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 SE APARTMENT_LIGHTS_PLUGIN F7 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 NE APARTMENT_LIGHTS_PLUGIN F7 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 N1 APARTMENT_LIGHTS_PLUGIN F7 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 N2 APARTMENT_LIGHTS_PLUGIN F7 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 S1 APARTMENT_LIGHTS_PLUGIN F7 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 S2 APARTMENT_LIGHTS_PLUGIN F7 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 SW APARTMENT_LIGHTS_PLUGIN F8 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 NW APARTMENT_LIGHTS_PLUGIN F8 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 SE APARTMENT_LIGHTS_PLUGIN F8 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 NE APARTMENT_LIGHTS_PLUGIN F8 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 N1 APARTMENT_LIGHTS_PLUGIN F8 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 N2 APARTMENT_LIGHTS_PLUGIN F8 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 S1 APARTMENT_LIGHTS_PLUGIN F8 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 S2 APARTMENT_LIGHTS_PLUGIN F8 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 SW APARTMENT_LIGHTS_PLUGIN F9 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 NW APARTMENT_LIGHTS_PLUGIN F9 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 SE APARTMENT_LIGHTS_PLUGIN F9 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 NE APARTMENT_LIGHTS_PLUGIN F9 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 N1 APARTMENT_LIGHTS_PLUGIN F9 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 N2 APARTMENT_LIGHTS_PLUGIN F9 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 S1 APARTMENT_LIGHTS_PLUGIN F9 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 S2 APARTMENT_LIGHTS_PLUGIN F9 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T SW APARTMENT_LIGHTS_PLUGIN T SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T NW APARTMENT_LIGHTS_PLUGIN T NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T SE APARTMENT_LIGHTS_PLUGIN T SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T NE APARTMENT_LIGHTS_PLUGIN T NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T N1 APARTMENT_LIGHTS_PLUGIN T N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T N2 APARTMENT_LIGHTS_PLUGIN T N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T S1 APARTMENT_LIGHTS_PLUGIN T S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T S2 APARTMENT_LIGHTS_PLUGIN T S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
Interior Lighting Total   2.2679 14974.03 33959.19               296.56


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 10364.00 AstronomicalClock -   83.68 83.68 162.79
Exterior Lighting Total 10364.00           162.79



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:13

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
CENTRAL BOILER Boiler:HotWater 276837.95 0.75    
CENTRAL TOWER EvaporativeFluidCooler:SingleSpeed 221470.36      


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
HEAT PUMP COOLING MODE AIRLOOP G SW Coil:Cooling:WaterToAirHeatPump:EquationFit   3842.70 2880.51 962.19 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NW Coil:Cooling:WaterToAirHeatPump:EquationFit   2958.00 2210.06 747.94 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP OFFICE Coil:Cooling:WaterToAirHeatPump:EquationFit   5610.84 4216.33 1394.51 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2057.38 1525.06 532.32 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1364.06 992.65 371.41 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1330.50 967.03 363.47 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2739.68 2020.41 719.27 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2831.51 2091.98 739.53 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4798.55 3620.45 1178.10 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3737.58 2811.66 925.92 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4756.20 3582.98 1173.22 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2718.42 2037.52 680.90 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1827.42 1347.69 479.73 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1797.53 1324.77 472.77 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3462.18 2579.09 883.08 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3495.78 2605.27 890.52 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4850.94 3658.87 1192.07 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3796.43 2855.25 941.18 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4518.65 3395.82 1122.83 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2776.34 2080.71 695.63 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1889.62 1394.74 494.88 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1859.66 1371.75 487.90 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3524.66 2626.38 898.28 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3540.44 2638.67 901.77 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4885.85 3684.28 1201.57 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3829.31 2879.22 950.10 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4527.09 3400.67 1126.41 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2812.66 2102.94 709.73 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1918.03 1415.97 502.06 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1888.04 1392.97 495.07 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3554.33 2648.46 905.87 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3567.55 2658.75 908.79 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4941.44 3726.11 1215.33 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3892.61 2925.00 967.61 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4581.05 3441.26 1139.78 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2856.48 2135.83 720.65 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1965.64 1452.11 513.54 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1935.64 1429.09 506.55 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3604.33 2686.55 917.79 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3617.14 2696.52 920.62 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4914.69 3704.10 1210.59 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3863.98 2901.70 962.27 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4556.18 3420.75 1135.43 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2821.07 2107.38 713.69 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1935.01 1428.09 506.92 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1905.17 1405.21 499.96 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3573.54 2661.88 911.66 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3586.28 2671.80 914.48 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4914.77 3703.11 1211.66 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3862.75 2899.82 962.93 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4557.80 3420.99 1136.81 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2813.19 2100.44 712.75 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1930.76 1424.44 506.32 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1913.34 1408.52 504.82 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3569.66 2658.25 911.41 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3582.35 2668.13 914.22 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4927.92 3712.40 1215.52 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3875.52 2908.90 966.63 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4572.10 3431.20 1140.91 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2819.01 2104.23 714.78 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1941.26 1432.18 509.08 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1924.71 1416.93 507.78 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3579.31 2665.20 914.10 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3592.01 2675.10 916.91 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5035.56 3795.22 1240.34 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3989.25 2996.34 992.91 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4666.71 3502.23 1164.48 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2992.31 2201.53 790.79 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2041.36 1508.85 532.51 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2024.47 1493.44 531.03 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3652.14 2721.33 930.81 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3666.45 2732.47 933.97 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SW Coil:Cooling:WaterToAirHeatPump:EquationFit   6102.07 4619.74 1482.33 0.76 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4880.66 3682.92 1197.74 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SE Coil:Cooling:WaterToAirHeatPump:EquationFit   5597.95 4227.27 1370.68 0.76 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3742.16 2783.06 959.10 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2896.99 2135.96 761.03 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2900.88 2136.76 764.12 0.74 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   4725.45 3557.61 1167.83 0.75 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   4738.94 3568.13 1170.82 0.75 0.00    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
None            


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
HEAT PUMP HEATING MODE AIRLOOP G SW Coil:Heating:WaterToAirHeatPump:EquationFit   3842.70 0.00
HEAT PUMP HEATING MODE AIRLOOP G NW Coil:Heating:WaterToAirHeatPump:EquationFit   2958.00 0.00
HEAT PUMP HEATING MODE AIRLOOP OFFICE Coil:Heating:WaterToAirHeatPump:EquationFit   5610.84 0.00
HEAT PUMP HEATING MODE AIRLOOP G NE Coil:Heating:WaterToAirHeatPump:EquationFit   2057.38 0.00
HEAT PUMP HEATING MODE AIRLOOP G N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1364.06 0.00
HEAT PUMP HEATING MODE AIRLOOP G N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1330.50 0.00
HEAT PUMP HEATING MODE AIRLOOP G S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2739.68 0.00
HEAT PUMP HEATING MODE AIRLOOP G S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2831.51 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4798.55 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3737.58 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4756.20 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2718.42 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1827.42 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1797.53 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3462.18 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3495.78 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4850.94 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3796.43 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4518.65 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2776.34 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1889.62 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1859.66 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3524.66 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3540.44 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4885.85 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3829.31 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4527.09 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2812.66 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1918.03 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1888.04 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3554.33 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3567.55 0.00
HEAT PUMP HEATING MODE AIRLOOP M SW Coil:Heating:WaterToAirHeatPump:EquationFit   4941.44 0.00
HEAT PUMP HEATING MODE AIRLOOP M NW Coil:Heating:WaterToAirHeatPump:EquationFit   3892.61 0.00
HEAT PUMP HEATING MODE AIRLOOP M SE Coil:Heating:WaterToAirHeatPump:EquationFit   4581.05 0.00
HEAT PUMP HEATING MODE AIRLOOP M NE Coil:Heating:WaterToAirHeatPump:EquationFit   2856.48 0.00
HEAT PUMP HEATING MODE AIRLOOP M N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1965.64 0.00
HEAT PUMP HEATING MODE AIRLOOP M N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1935.64 0.00
HEAT PUMP HEATING MODE AIRLOOP M S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3604.33 0.00
HEAT PUMP HEATING MODE AIRLOOP M S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3617.14 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4914.69 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3863.98 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4556.18 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2821.07 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1935.01 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1905.17 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3573.54 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3586.28 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4914.77 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3862.75 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4557.80 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2813.19 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1930.76 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1913.34 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3569.66 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3582.35 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4927.92 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3875.52 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4572.10 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2819.01 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1941.26 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1924.71 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3579.31 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3592.01 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SW Coil:Heating:WaterToAirHeatPump:EquationFit   5035.56 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3989.25 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4666.71 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NE Coil:Heating:WaterToAirHeatPump:EquationFit   2992.31 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2041.36 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2024.47 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3652.14 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3666.45 0.00
HEAT PUMP HEATING MODE AIRLOOP T SW Coil:Heating:WaterToAirHeatPump:EquationFit   6102.07 0.00
HEAT PUMP HEATING MODE AIRLOOP T NW Coil:Heating:WaterToAirHeatPump:EquationFit   4880.66 0.00
HEAT PUMP HEATING MODE AIRLOOP T SE Coil:Heating:WaterToAirHeatPump:EquationFit   5597.95 0.00
HEAT PUMP HEATING MODE AIRLOOP T NE Coil:Heating:WaterToAirHeatPump:EquationFit   3742.16 0.00
HEAT PUMP HEATING MODE AIRLOOP T N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2896.99 0.00
HEAT PUMP HEATING MODE AIRLOOP T N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2900.88 0.00
HEAT PUMP HEATING MODE AIRLOOP T S1 Coil:Heating:WaterToAirHeatPump:EquationFit   4725.45 0.00
HEAT PUMP HEATING MODE AIRLOOP T S2 Coil:Heating:WaterToAirHeatPump:EquationFit   4738.94 0.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW Coil:Heating:Electric   2633.20 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW Coil:Heating:Electric   2633.31 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE Coil:Heating:Electric   3380.53 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE Coil:Heating:Electric   2633.31 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 Coil:Heating:Electric   2008.22 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 Coil:Heating:Electric   2008.22 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 Coil:Heating:Electric   2004.40 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 Coil:Heating:Electric   2010.69 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW Coil:Heating:Electric   2528.11 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW Coil:Heating:Electric   2523.45 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE Coil:Heating:Electric   2546.88 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE Coil:Heating:Electric   2523.45 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 Coil:Heating:Electric   1755.15 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 Coil:Heating:Electric   1755.15 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 Coil:Heating:Electric   1762.58 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 Coil:Heating:Electric   1763.83 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW Coil:Heating:Electric   2515.86 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW Coil:Heating:Electric   2512.54 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE Coil:Heating:Electric   2517.97 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE Coil:Heating:Electric   2512.54 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 Coil:Heating:Electric   1712.12 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 Coil:Heating:Electric   1712.12 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 Coil:Heating:Electric   1716.20 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 Coil:Heating:Electric   1716.40 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW Coil:Heating:Electric   2554.64 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW Coil:Heating:Electric   2552.57 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE Coil:Heating:Electric   2554.87 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE Coil:Heating:Electric   2552.57 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 Coil:Heating:Electric   1725.84 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 Coil:Heating:Electric   1725.84 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 Coil:Heating:Electric   1728.44 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 Coil:Heating:Electric   1728.47 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW Coil:Heating:Electric   2574.82 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW Coil:Heating:Electric   2572.63 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE Coil:Heating:Electric   2574.84 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE Coil:Heating:Electric   2572.63 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 Coil:Heating:Electric   1726.94 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 Coil:Heating:Electric   1726.94 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 Coil:Heating:Electric   1729.62 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 Coil:Heating:Electric   1729.63 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW Coil:Heating:Electric   2653.56 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW Coil:Heating:Electric   2652.81 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE Coil:Heating:Electric   2653.56 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE Coil:Heating:Electric   2652.81 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 Coil:Heating:Electric   1786.44 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 Coil:Heating:Electric   1786.44 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 Coil:Heating:Electric   1787.61 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 Coil:Heating:Electric   1787.61 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW Coil:Heating:Electric   2706.80 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW Coil:Heating:Electric   2706.44 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE Coil:Heating:Electric   2706.80 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE Coil:Heating:Electric   2706.44 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 Coil:Heating:Electric   1824.23 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 Coil:Heating:Electric   1824.23 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 Coil:Heating:Electric   1825.03 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 Coil:Heating:Electric   1825.03 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW Coil:Heating:Electric   2764.07 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW Coil:Heating:Electric   2763.83 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE Coil:Heating:Electric   2764.07 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE Coil:Heating:Electric   2763.83 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 Coil:Heating:Electric   1867.67 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 Coil:Heating:Electric   1867.67 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 Coil:Heating:Electric   1868.32 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 Coil:Heating:Electric   1868.32 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW Coil:Heating:Electric   2934.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW Coil:Heating:Electric   2932.49 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE Coil:Heating:Electric   2934.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE Coil:Heating:Electric   2932.49 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 Coil:Heating:Electric   2016.33 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 Coil:Heating:Electric   2016.33 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 Coil:Heating:Electric   2018.46 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 Coil:Heating:Electric   2018.46 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW Coil:Heating:Electric   3525.16 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW Coil:Heating:Electric   3529.64 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE Coil:Heating:Electric   3525.16 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE Coil:Heating:Electric   3529.64 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 Coil:Heating:Electric   2650.04 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 Coil:Heating:Electric   2650.04 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 Coil:Heating:Electric   2642.57 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 Coil:Heating:Electric   2642.57 1.00


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
AIRLOOP G SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 293.43 1160.84 1.00 General
AIRLOOP G NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 225.38 1160.84 1.00 General
AIRLOOP OFFICE SUPPLY FAN Fan:OnOff 0.54 622.50 0.37 429.40 1160.84 1.00 General
AIRLOOP G NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 154.49 1160.84 1.00 General
AIRLOOP G N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.09 98.77 1160.84 1.00 General
AIRLOOP G N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.08 96.07 1160.84 1.00 General
AIRLOOP G S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 201.27 1160.84 1.00 General
AIRLOOP G S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 208.89 1160.84 1.00 General
AIRLOOP F2 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 372.17 1160.84 1.00 General
AIRLOOP F2 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 289.32 1160.84 1.00 General
AIRLOOP F2 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 367.43 1160.84 1.00 General
AIRLOOP F2 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 209.08 1160.84 1.00 General
AIRLOOP F2 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 136.33 1160.84 1.00 General
AIRLOOP F2 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 133.90 1160.84 1.00 General
AIRLOOP F2 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 260.38 1160.84 1.00 General
AIRLOOP F2 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 263.17 1160.84 1.00 General
AIRLOOP F3 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 376.14 1160.84 1.00 General
AIRLOOP F3 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 293.85 1160.84 1.00 General
AIRLOOP F3 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 347.34 1160.84 1.00 General
AIRLOOP F3 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 213.58 1160.84 1.00 General
AIRLOOP F3 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 141.27 1160.84 1.00 General
AIRLOOP F3 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 138.84 1160.84 1.00 General
AIRLOOP F3 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 265.34 1160.84 1.00 General
AIRLOOP F3 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 266.65 1160.84 1.00 General
AIRLOOP F4 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.33 378.75 1160.84 1.00 General
AIRLOOP F4 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 296.32 1160.84 1.00 General
AIRLOOP F4 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 347.76 1160.84 1.00 General
AIRLOOP F4 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 215.05 1160.84 1.00 General
AIRLOOP F4 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 143.49 1160.84 1.00 General
AIRLOOP F4 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 141.05 1160.84 1.00 General
AIRLOOP F4 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 267.64 1160.84 1.00 General
AIRLOOP F4 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 268.73 1160.84 1.00 General
AIRLOOP M SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.33 383.14 1160.84 1.00 General
AIRLOOP M NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 300.63 1160.84 1.00 General
AIRLOOP M SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 352.01 1160.84 1.00 General
AIRLOOP M NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 218.50 1160.84 1.00 General
AIRLOOP M N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 147.30 1160.84 1.00 General
AIRLOOP M N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 144.86 1160.84 1.00 General
AIRLOOP M S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 271.65 1160.84 1.00 General
AIRLOOP M S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 272.71 1160.84 1.00 General
AIRLOOP F6 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.33 380.72 1160.84 1.00 General
AIRLOOP F6 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 298.09 1160.84 1.00 General
AIRLOOP F6 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 349.76 1160.84 1.00 General
AIRLOOP F6 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 215.41 1160.84 1.00 General
AIRLOOP F6 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 144.72 1160.84 1.00 General
AIRLOOP F6 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 142.30 1160.84 1.00 General
AIRLOOP F6 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 268.98 1160.84 1.00 General
AIRLOOP F6 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 270.04 1160.84 1.00 General
AIRLOOP F7 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.33 380.56 1160.84 1.00 General
AIRLOOP F7 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 297.83 1160.84 1.00 General
AIRLOOP F7 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 349.73 1160.84 1.00 General
AIRLOOP F7 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 214.62 1160.84 1.00 General
AIRLOOP F7 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 144.31 1160.84 1.00 General
AIRLOOP F7 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 141.94 1160.84 1.00 General
AIRLOOP F7 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 268.56 1160.84 1.00 General
AIRLOOP F7 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 269.61 1160.84 1.00 General
AIRLOOP F8 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.33 381.50 1160.84 1.00 General
AIRLOOP F8 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 298.76 1160.84 1.00 General
AIRLOOP F8 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 350.77 1160.84 1.00 General
AIRLOOP F8 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 214.99 1160.84 1.00 General
AIRLOOP F8 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 145.11 1160.84 1.00 General
AIRLOOP F8 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 142.81 1160.84 1.00 General
AIRLOOP F8 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 269.27 1160.84 1.00 General
AIRLOOP F8 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 270.32 1160.84 1.00 General
AIRLOOP F9 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.34 390.29 1160.84 1.00 General
AIRLOOP F9 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.27 308.03 1160.84 1.00 General
AIRLOOP F9 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 358.02 1160.84 1.00 General
AIRLOOP F9 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 219.50 1160.84 1.00 General
AIRLOOP F9 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 153.23 1160.84 1.00 General
AIRLOOP F9 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 150.91 1160.84 1.00 General
AIRLOOP F9 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 275.22 1160.84 1.00 General
AIRLOOP F9 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 276.41 1160.84 1.00 General
AIRLOOP T SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.41 477.56 1160.84 1.00 General
AIRLOOP T NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.33 379.89 1160.84 1.00 General
AIRLOOP T SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.38 435.61 1160.84 1.00 General
AIRLOOP T NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 281.33 1160.84 1.00 General
AIRLOOP T N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 213.21 1160.84 1.00 General
AIRLOOP T N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 212.97 1160.84 1.00 General
AIRLOOP T S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 364.65 1160.84 1.00 General
AIRLOOP T S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 365.77 1160.84 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
SHWSYS1 PUMP Pump:ConstantSpeed Intermittent 29891.00 0.0003 36.93 127739.32 0.30
PLANT CIRC PUMP Pump:ConstantSpeed Intermittent 224180.02 0.0060 1922.92 319344.75 0.90


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
SHWSYS1 WATER HEATER WaterHeater:Mixed 2.27 175842.64 0.80 0.00 0.00



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:13

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 2671.19 3205.43 0.211 0.253 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 32.61 0.00850
G NW APARTMENT 2051.68 2462.01 0.162 0.194 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 17:45:00 29.99 0.00850
OFFICE 3908.92 4690.70 0.308 0.370 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.11 0.00850
G NE APARTMENT 1406.29 1687.55 0.111 0.133 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 10:30:00 28.60 0.00850
G N1 APARTMENT 899.12 1078.95 0.071 0.085 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:45:00 27.87 0.00850
G N2 APARTMENT 874.52 1049.43 0.069 0.083 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:45:00 27.87 0.00850
G S1 APARTMENT 1832.21 2198.65 0.144 0.173 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.11 0.00850
G S2 APARTMENT 1901.56 2281.87 0.150 0.180 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.11 0.00850
F2 SW APARTMENT 3387.90 4065.48 0.267 0.321 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 32.61 0.00850
F2 NW APARTMENT 2633.70 3160.45 0.208 0.249 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 17:45:00 29.99 0.00850
F2 SE APARTMENT 3344.83 4013.79 0.264 0.317 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.11 0.00850
F2 NE APARTMENT 1903.26 2283.91 0.150 0.180 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 10:30:00 28.60 0.00850
F2 N1 APARTMENT 1241.03 1489.24 0.098 0.117 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:45:00 27.87 0.00850
F2 N2 APARTMENT 1218.93 1462.71 0.096 0.115 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:45:00 27.87 0.00850
F2 S1 APARTMENT 2370.26 2844.31 0.187 0.224 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.30 0.00850
F2 S2 APARTMENT 2395.65 2874.79 0.189 0.227 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.30 0.00850
F3 SW APARTMENT 3424.04 4108.85 0.270 0.324 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 32.61 0.00850
F3 NW APARTMENT 2674.96 3209.95 0.211 0.253 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 17:45:00 29.99 0.00850
F3 SE APARTMENT 3161.87 3794.24 0.249 0.299 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.11 0.00850
F3 NE APARTMENT 1944.26 2333.12 0.153 0.184 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 10:30:00 28.60 0.00850
F3 N1 APARTMENT 1286.05 1543.25 0.101 0.122 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:45:00 27.87 0.00850
F3 N2 APARTMENT 1263.88 1516.65 0.100 0.120 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:45:00 27.87 0.00850
F3 S1 APARTMENT 2415.44 2898.53 0.190 0.229 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.30 0.00850
F3 S2 APARTMENT 2427.37 2912.85 0.191 0.230 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.30 0.00850
F4 SW APARTMENT 3447.84 4137.41 0.272 0.326 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 32.61 0.00850
F4 NW APARTMENT 2697.42 3236.91 0.213 0.255 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 17:45:00 29.99 0.00850
F4 SE APARTMENT 3165.72 3798.86 0.250 0.300 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.11 0.00850
F4 NE APARTMENT 1957.67 2349.21 0.154 0.185 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 10:45:00 29.18 0.00850
F4 N1 APARTMENT 1306.22 1567.46 0.103 0.124 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:45:00 27.87 0.00850
F4 N2 APARTMENT 1284.04 1540.85 0.101 0.122 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:45:00 27.87 0.00850
F4 S1 APARTMENT 2436.34 2923.61 0.192 0.231 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.30 0.00850
F4 S2 APARTMENT 2446.33 2935.60 0.193 0.231 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.30 0.00850
M SW APARTMENT 3487.76 4185.31 0.275 0.330 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 32.61 0.00850
M NW APARTMENT 2736.71 3284.05 0.216 0.259 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 17:30:00 30.37 0.00850
M SE APARTMENT 3204.43 3845.31 0.253 0.303 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.11 0.00850
M NE APARTMENT 1989.02 2386.82 0.157 0.188 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 10:45:00 29.18 0.00850
M N1 APARTMENT 1340.86 1609.03 0.106 0.127 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:45:00 27.87 0.00850
M N2 APARTMENT 1318.66 1582.40 0.104 0.125 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:45:00 27.87 0.00850
M S1 APARTMENT 2472.87 2967.44 0.195 0.234 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.30 0.00850
M S2 APARTMENT 2482.54 2979.05 0.196 0.235 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.30 0.00850
F6 SW APARTMENT 3465.76 4158.92 0.273 0.328 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 32.61 0.00850
F6 NW APARTMENT 2713.55 3256.26 0.214 0.257 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 17:30:00 30.37 0.00850
F6 SE APARTMENT 3183.91 3820.69 0.251 0.301 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.11 0.00850
F6 NE APARTMENT 1960.91 2353.10 0.155 0.186 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 10:45:00 29.18 0.00850
F6 N1 APARTMENT 1317.42 1580.90 0.104 0.125 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:45:00 27.87 0.00850
F6 N2 APARTMENT 1295.36 1554.43 0.102 0.123 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:45:00 27.87 0.00850
F6 S1 APARTMENT 2448.58 2938.30 0.193 0.232 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.30 0.00850
F6 S2 APARTMENT 2458.21 2949.85 0.194 0.233 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.30 0.00850
F7 SW APARTMENT 3464.27 4157.12 0.273 0.328 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 32.61 0.00850
F7 NW APARTMENT 2711.24 3253.49 0.214 0.257 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 17:30:00 30.37 0.00850
F7 SE APARTMENT 3183.62 3820.35 0.251 0.301 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.11 0.00850
F7 NE APARTMENT 1953.75 2344.50 0.154 0.185 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 10:45:00 29.18 0.00850
F7 N1 APARTMENT 1313.69 1576.43 0.104 0.124 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:45:00 27.87 0.00850
F7 N2 APARTMENT 1292.09 1550.51 0.102 0.122 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 28.45 0.00850
F7 S1 APARTMENT 2444.74 2933.69 0.193 0.231 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.30 0.00850
F7 S2 APARTMENT 2454.33 2945.20 0.194 0.232 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.30 0.00850
F8 SW APARTMENT 3472.81 4167.38 0.274 0.329 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 32.61 0.00850
F8 NW APARTMENT 2719.62 3263.54 0.214 0.257 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 17:30:00 30.37 0.00850
F8 SE APARTMENT 3193.06 3831.68 0.252 0.302 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.11 0.00850
F8 NE APARTMENT 1957.05 2348.46 0.154 0.185 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 10:45:00 29.18 0.00850
F8 N1 APARTMENT 1320.99 1585.18 0.104 0.125 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:45:00 27.87 0.00850
F8 N2 APARTMENT 1300.03 1560.04 0.103 0.123 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 28.45 0.00850
F8 S1 APARTMENT 2451.21 2941.45 0.193 0.232 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.30 0.00850
F8 S2 APARTMENT 2460.81 2952.97 0.194 0.233 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.30 0.00850
F9 SW APARTMENT 3552.83 4263.39 0.280 0.336 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 32.61 0.00850
F9 NW APARTMENT 2804.08 3364.89 0.221 0.265 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 17:30:00 30.37 0.00850
F9 SE APARTMENT 3259.08 3910.89 0.257 0.308 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.30 0.00850
F9 NE APARTMENT 1998.13 2397.76 0.158 0.189 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:45:00 33.30 0.00850
F9 N1 APARTMENT 1394.88 1673.85 0.110 0.132 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:45:00 27.87 0.00850
F9 N2 APARTMENT 1373.76 1648.52 0.108 0.130 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:30:00 28.45 0.00850
F9 S1 APARTMENT 2505.38 3006.46 0.198 0.237 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.30 0.00850
F9 S2 APARTMENT 2516.19 3019.43 0.198 0.238 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.30 0.00850
T SW APARTMENT 4347.28 5216.74 0.343 0.411 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 15:15:00 33.07 0.00850
T NW APARTMENT 3458.16 4149.79 0.273 0.327 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 16:45:00 31.45 0.00850
T SE APARTMENT 3965.40 4758.48 0.313 0.375 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.11 0.00850
T NE APARTMENT 2560.99 3073.19 0.202 0.242 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:30:00 33.30 0.00850
T N1 APARTMENT 1940.86 2329.03 0.153 0.184 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 15:15:00 33.07 0.00850
T N2 APARTMENT 1938.70 2326.44 0.153 0.183 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:45:00 33.30 0.00850
T S1 APARTMENT 3319.45 3983.35 0.262 0.314 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.11 0.00850
T S2 APARTMENT 3329.67 3995.60 0.263 0.315 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.11 0.00850


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1506.87 1808.24 0.068 0.081 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.60 0.00237
G NW APARTMENT 1506.96 1808.35 0.068 0.081 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.60 0.00237
OFFICE 1801.79 2162.15 0.081 0.097 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 18:45:00 -5.60 0.00237
G NE APARTMENT 1506.96 1808.35 0.068 0.081 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.60 0.00237
G N1 APARTMENT 978.34 1174.01 0.044 0.053 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.60 0.00237
G N2 APARTMENT 978.34 1174.01 0.044 0.053 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.60 0.00237
G S1 APARTMENT 975.11 1170.13 0.044 0.052 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.60 0.00237
G S2 APARTMENT 980.43 1176.52 0.044 0.053 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.60 0.00237
F2 SW APARTMENT 1418.02 1701.62 0.064 0.076 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F2 NW APARTMENT 1414.08 1696.90 0.063 0.076 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F2 SE APARTMENT 1433.89 1720.67 0.064 0.077 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F2 NE APARTMENT 1414.08 1696.90 0.063 0.076 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F2 N1 APARTMENT 764.35 917.22 0.034 0.041 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F2 N2 APARTMENT 764.35 917.22 0.034 0.041 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F2 S1 APARTMENT 770.63 924.75 0.035 0.041 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F2 S2 APARTMENT 771.69 926.02 0.035 0.041 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F3 SW APARTMENT 1407.66 1689.20 0.063 0.076 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F3 NW APARTMENT 1404.86 1685.83 0.063 0.076 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F3 SE APARTMENT 1409.45 1691.34 0.063 0.076 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F3 NE APARTMENT 1404.86 1685.83 0.063 0.076 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F3 N1 APARTMENT 727.96 873.56 0.033 0.039 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F3 N2 APARTMENT 727.96 873.56 0.033 0.039 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F3 S1 APARTMENT 731.41 877.70 0.033 0.039 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F3 S2 APARTMENT 731.58 877.90 0.033 0.039 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F4 SW APARTMENT 1440.47 1728.56 0.065 0.077 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F4 NW APARTMENT 1438.72 1726.46 0.064 0.077 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F4 SE APARTMENT 1440.66 1728.79 0.065 0.077 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F4 NE APARTMENT 1438.72 1726.46 0.064 0.077 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F4 N1 APARTMENT 739.58 887.49 0.033 0.040 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F4 N2 APARTMENT 739.58 887.49 0.033 0.040 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F4 S1 APARTMENT 741.77 890.12 0.033 0.040 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F4 S2 APARTMENT 741.79 890.15 0.033 0.040 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
M SW APARTMENT 1457.53 1749.04 0.065 0.078 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
M NW APARTMENT 1455.69 1746.82 0.065 0.078 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
M SE APARTMENT 1457.55 1749.07 0.065 0.078 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
M NE APARTMENT 1455.69 1746.82 0.065 0.078 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
M N1 APARTMENT 740.50 888.60 0.033 0.040 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
M N2 APARTMENT 740.50 888.60 0.033 0.040 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
M S1 APARTMENT 742.77 891.33 0.033 0.040 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
M S2 APARTMENT 742.78 891.33 0.033 0.040 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F6 SW APARTMENT 1524.12 1828.95 0.068 0.082 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F6 NW APARTMENT 1523.49 1828.19 0.068 0.082 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F6 SE APARTMENT 1524.13 1828.95 0.068 0.082 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F6 NE APARTMENT 1523.49 1828.19 0.068 0.082 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F6 N1 APARTMENT 790.82 948.98 0.035 0.043 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F6 N2 APARTMENT 790.82 948.98 0.035 0.043 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F6 S1 APARTMENT 791.82 950.18 0.035 0.043 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F6 S2 APARTMENT 791.82 950.18 0.035 0.043 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F7 SW APARTMENT 1569.15 1882.98 0.070 0.084 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F7 NW APARTMENT 1568.84 1882.61 0.070 0.084 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F7 SE APARTMENT 1569.15 1882.98 0.070 0.084 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F7 NE APARTMENT 1568.84 1882.61 0.070 0.084 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F7 N1 APARTMENT 822.78 987.34 0.037 0.044 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F7 N2 APARTMENT 822.78 987.34 0.037 0.044 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F7 S1 APARTMENT 823.46 988.15 0.037 0.044 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F7 S2 APARTMENT 823.46 988.15 0.037 0.044 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F8 SW APARTMENT 1617.58 1941.10 0.072 0.087 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F8 NW APARTMENT 1617.38 1940.86 0.072 0.087 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F8 SE APARTMENT 1617.58 1941.10 0.072 0.087 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F8 NE APARTMENT 1617.38 1940.86 0.072 0.087 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F8 N1 APARTMENT 859.52 1031.42 0.039 0.046 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F8 N2 APARTMENT 859.52 1031.42 0.039 0.046 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F8 S1 APARTMENT 860.07 1032.08 0.039 0.046 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F8 S2 APARTMENT 860.07 1032.08 0.039 0.046 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F9 SW APARTMENT 1761.83 2114.20 0.079 0.095 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F9 NW APARTMENT 1760.01 2112.01 0.079 0.095 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F9 SE APARTMENT 1761.83 2114.20 0.079 0.095 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F9 NE APARTMENT 1760.01 2112.01 0.079 0.095 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F9 N1 APARTMENT 985.23 1182.28 0.044 0.053 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F9 N2 APARTMENT 985.23 1182.28 0.044 0.053 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F9 S1 APARTMENT 987.03 1184.44 0.044 0.053 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
F9 S2 APARTMENT 987.03 1184.44 0.044 0.053 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
T SW APARTMENT 2261.21 2713.45 0.101 0.122 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
T NW APARTMENT 2264.99 2717.99 0.101 0.122 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
T SE APARTMENT 2261.21 2713.45 0.101 0.122 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
T NE APARTMENT 2264.99 2717.99 0.101 0.122 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
T N1 APARTMENT 1521.14 1825.36 0.068 0.082 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
T N2 APARTMENT 1521.14 1825.36 0.068 0.082 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
T S1 APARTMENT 1514.82 1817.78 0.068 0.081 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237
T S2 APARTMENT 1514.82 1817.78 0.068 0.081 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.60 0.00237


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
AIRLOOP G SW 0.25 0.25 0.08 0.08
AIRLOOP G NW 0.19 0.19 0.08 0.08
AIRLOOP OFFICE 0.37 0.37 0.10 0.10
AIRLOOP G NE 0.13 0.13 0.08 0.08
AIRLOOP G N1 0.09 0.09 0.05 0.05
AIRLOOP G N2 0.08 0.08 0.05 0.05
AIRLOOP G S1 0.17 0.17 0.05 0.05
AIRLOOP G S2 0.18 0.18 0.05 0.05
AIRLOOP F2 SW 0.32 0.32 0.08 0.08
AIRLOOP F2 NW 0.25 0.25 0.08 0.08
AIRLOOP F2 SE 0.32 0.32 0.08 0.08
AIRLOOP F2 NE 0.18 0.18 0.08 0.08
AIRLOOP F2 N1 0.12 0.12 0.04 0.04
AIRLOOP F2 N2 0.12 0.12 0.04 0.04
AIRLOOP F2 S1 0.22 0.22 0.04 0.04
AIRLOOP F2 S2 0.23 0.23 0.04 0.04
AIRLOOP F3 SW 0.32 0.32 0.08 0.08
AIRLOOP F3 NW 0.25 0.25 0.08 0.08
AIRLOOP F3 SE 0.30 0.30 0.08 0.08
AIRLOOP F3 NE 0.18 0.18 0.08 0.08
AIRLOOP F3 N1 0.12 0.12 0.04 0.04
AIRLOOP F3 N2 0.12 0.12 0.04 0.04
AIRLOOP F3 S1 0.23 0.23 0.04 0.04
AIRLOOP F3 S2 0.23 0.23 0.04 0.04
AIRLOOP F4 SW 0.33 0.33 0.08 0.08
AIRLOOP F4 NW 0.26 0.26 0.08 0.08
AIRLOOP F4 SE 0.30 0.30 0.08 0.08
AIRLOOP F4 NE 0.19 0.19 0.08 0.08
AIRLOOP F4 N1 0.12 0.12 0.04 0.04
AIRLOOP F4 N2 0.12 0.12 0.04 0.04
AIRLOOP F4 S1 0.23 0.23 0.04 0.04
AIRLOOP F4 S2 0.23 0.23 0.04 0.04
AIRLOOP M SW 0.33 0.33 0.08 0.08
AIRLOOP M NW 0.26 0.26 0.08 0.08
AIRLOOP M SE 0.30 0.30 0.08 0.08
AIRLOOP M NE 0.19 0.19 0.08 0.08
AIRLOOP M N1 0.13 0.13 0.04 0.04
AIRLOOP M N2 0.12 0.12 0.04 0.04
AIRLOOP M S1 0.23 0.23 0.04 0.04
AIRLOOP M S2 0.23 0.23 0.04 0.04
AIRLOOP F6 SW 0.33 0.33 0.08 0.08
AIRLOOP F6 NW 0.26 0.26 0.08 0.08
AIRLOOP F6 SE 0.30 0.30 0.08 0.08
AIRLOOP F6 NE 0.19 0.19 0.08 0.08
AIRLOOP F6 N1 0.12 0.12 0.04 0.04
AIRLOOP F6 N2 0.12 0.12 0.04 0.04
AIRLOOP F6 S1 0.23 0.23 0.04 0.04
AIRLOOP F6 S2 0.23 0.23 0.04 0.04
AIRLOOP F7 SW 0.33 0.33 0.08 0.08
AIRLOOP F7 NW 0.26 0.26 0.08 0.08
AIRLOOP F7 SE 0.30 0.30 0.08 0.08
AIRLOOP F7 NE 0.18 0.18 0.08 0.08
AIRLOOP F7 N1 0.12 0.12 0.04 0.04
AIRLOOP F7 N2 0.12 0.12 0.04 0.04
AIRLOOP F7 S1 0.23 0.23 0.04 0.04
AIRLOOP F7 S2 0.23 0.23 0.04 0.04
AIRLOOP F8 SW 0.33 0.33 0.09 0.09
AIRLOOP F8 NW 0.26 0.26 0.09 0.09
AIRLOOP F8 SE 0.30 0.30 0.09 0.09
AIRLOOP F8 NE 0.19 0.19 0.09 0.09
AIRLOOP F8 N1 0.13 0.13 0.05 0.05
AIRLOOP F8 N2 0.12 0.12 0.05 0.05
AIRLOOP F8 S1 0.23 0.23 0.05 0.05
AIRLOOP F8 S2 0.23 0.23 0.05 0.05
AIRLOOP F9 SW 0.34 0.34 0.09 0.09
AIRLOOP F9 NW 0.27 0.27 0.09 0.09
AIRLOOP F9 SE 0.31 0.31 0.09 0.09
AIRLOOP F9 NE 0.19 0.19 0.09 0.09
AIRLOOP F9 N1 0.13 0.13 0.05 0.05
AIRLOOP F9 N2 0.13 0.13 0.05 0.05
AIRLOOP F9 S1 0.24 0.24 0.05 0.05
AIRLOOP F9 S2 0.24 0.24 0.05 0.05
AIRLOOP T SW 0.41 0.41 0.12 0.12
AIRLOOP T NW 0.33 0.33 0.12 0.12
AIRLOOP T SE 0.38 0.38 0.12 0.12
AIRLOOP T NE 0.24 0.24 0.12 0.12
AIRLOOP T N1 0.18 0.18 0.08 0.08
AIRLOOP T N2 0.18 0.18 0.08 0.08
AIRLOOP T S1 0.31 0.31 0.08 0.08
AIRLOOP T S2 0.32 0.32 0.08 0.08



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:13

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 2023.50 5856.00 82.50
G NW APARTMENT 1655.50 6542.25 178.25
OFFICE 919.75 919.25 3.75
G NE APARTMENT 1637.75 6662.25 190.25
G N1 APARTMENT 1162.25 6889.00 118.75
G N2 APARTMENT 1159.25 6910.50 121.75
G S1 APARTMENT 1809.00 6027.00 55.00
G S2 APARTMENT 1874.50 5939.00 52.50
F2 SW APARTMENT 3063.50 4435.50 31.75
F2 NW APARTMENT 2367.00 5552.00 76.25
F2 SE APARTMENT 3335.50 4245.75 24.50
F2 NE APARTMENT 2271.00 5755.50 83.75
F2 N1 APARTMENT 1971.50 5958.00 44.75
F2 N2 APARTMENT 1961.75 5980.00 45.50
F2 S1 APARTMENT 2963.25 4346.75 12.00
F2 S2 APARTMENT 3001.00 4303.25 11.00
F3 SW APARTMENT 3341.75 4167.50 24.75
F3 NW APARTMENT 2523.25 5316.00 68.75
F3 SE APARTMENT 3346.50 4231.75 23.75
F3 NE APARTMENT 2415.00 5527.75 71.25
F3 N1 APARTMENT 2185.50 5623.50 31.25
F3 N2 APARTMENT 2170.25 5659.00 31.25
F3 S1 APARTMENT 3389.25 3875.25 6.50
F3 S2 APARTMENT 3394.00 3873.25 6.50
F4 SW APARTMENT 3410.75 4130.00 24.25
F4 NW APARTMENT 2570.25 5248.00 69.25
F4 SE APARTMENT 3361.25 4258.25 24.25
F4 NE APARTMENT 2452.00 5467.25 71.25
F4 N1 APARTMENT 2252.75 5504.75 29.00
F4 N2 APARTMENT 2234.50 5537.75 29.75
F4 S1 APARTMENT 3533.50 3767.00 6.50
F4 S2 APARTMENT 3530.75 3776.50 6.50
M SW APARTMENT 3421.75 4137.50 23.75
M NW APARTMENT 2583.50 5247.50 67.00
M SE APARTMENT 3359.00 4279.50 23.75
M NE APARTMENT 2463.00 5464.25 68.75
M N1 APARTMENT 2292.50 5468.50 27.50
M N2 APARTMENT 2272.25 5498.50 27.00
M S1 APARTMENT 3572.50 3749.75 6.50
M S2 APARTMENT 3566.75 3760.25 6.50
F6 SW APARTMENT 3255.75 4308.75 25.75
F6 NW APARTMENT 2449.75 5405.00 71.25
F6 SE APARTMENT 3184.50 4439.25 25.50
F6 NE APARTMENT 2332.25 5608.75 75.75
F6 N1 APARTMENT 2134.50 5639.50 33.00
F6 N2 APARTMENT 2119.75 5670.50 33.00
F6 S1 APARTMENT 3374.25 3935.75 6.00
F6 S2 APARTMENT 3363.25 3948.75 5.75
F7 SW APARTMENT 3154.50 4430.50 27.25
F7 NW APARTMENT 2368.75 5520.75 74.25
F7 SE APARTMENT 3081.00 4565.00 27.25
F7 NE APARTMENT 2251.00 5712.50 81.00
F7 N1 APARTMENT 2036.50 5767.50 36.50
F7 N2 APARTMENT 2020.25 5795.50 36.50
F7 S1 APARTMENT 3233.00 4082.00 5.00
F7 S2 APARTMENT 3224.00 4093.25 5.00
F8 SW APARTMENT 3060.75 4544.75 28.00
F8 NW APARTMENT 2301.75 5622.25 78.75
F8 SE APARTMENT 2988.00 4670.00 28.25
F8 NE APARTMENT 2177.75 5810.50 86.75
F8 N1 APARTMENT 1968.75 5870.25 40.00
F8 N2 APARTMENT 1956.75 5895.00 39.75
F8 S1 APARTMENT 3112.25 4231.50 5.75
F8 S2 APARTMENT 3108.00 4244.25 5.50
F9 SW APARTMENT 2916.00 4718.25 38.50
F9 NW APARTMENT 2241.00 5746.50 100.50
F9 SE APARTMENT 2853.25 4827.50 40.75
F9 NE APARTMENT 2109.75 5929.50 110.25
F9 N1 APARTMENT 1909.50 5990.00 48.25
F9 N2 APARTMENT 1888.00 6021.25 47.50
F9 S1 APARTMENT 2940.00 4482.00 9.75
F9 S2 APARTMENT 2934.00 4491.75 9.75
T SW APARTMENT 2665.50 5279.75 233.75
T NW APARTMENT 2164.75 6186.75 361.75
T SE APARTMENT 2718.50 5353.00 234.50
T NE APARTMENT 2196.75 6309.25 371.25
T N1 APARTMENT 1790.75 6387.75 166.75
T N2 APARTMENT 1781.50 6396.25 165.75
T S1 APARTMENT 2595.75 5067.50 81.25
T S2 APARTMENT 2593.25 5075.00 81.50
G CORRIDOR 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00
Facility 4423.00 7137.25 449.25
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 1.50 0.00 1.50 0.00
G NW APARTMENT 3.00 23.00 3.00 23.00
OFFICE 2.75 0.00 0.00 0.00
G NE APARTMENT 6.50 40.50 6.50 40.50
G N1 APARTMENT 7.00 48.00 7.00 48.00
G N2 APARTMENT 7.50 53.00 7.50 53.00
G S1 APARTMENT 6.00 0.00 6.00 0.00
G S2 APARTMENT 5.25 0.00 5.25 0.00
F2 SW APARTMENT 0.25 0.00 0.25 0.00
F2 NW APARTMENT 1.50 21.75 1.50 21.75
F2 SE APARTMENT 0.50 0.00 0.50 0.00
F2 NE APARTMENT 4.75 48.75 4.75 48.75
F2 N1 APARTMENT 4.50 49.75 4.50 49.75
F2 N2 APARTMENT 5.00 53.00 5.00 53.00
F2 S1 APARTMENT 3.25 0.00 3.25 0.00
F2 S2 APARTMENT 4.00 0.00 4.00 0.00
F3 SW APARTMENT 0.25 0.00 0.25 0.00
F3 NW APARTMENT 1.50 23.00 1.50 23.00
F3 SE APARTMENT 1.50 0.00 1.50 0.00
F3 NE APARTMENT 4.00 54.75 4.00 54.75
F3 N1 APARTMENT 6.50 56.75 6.50 56.75
F3 N2 APARTMENT 6.25 60.75 6.25 60.75
F3 S1 APARTMENT 1.25 0.00 1.25 0.00
F3 S2 APARTMENT 2.50 0.00 2.50 0.00
F4 SW APARTMENT 0.50 0.00 0.50 0.00
F4 NW APARTMENT 0.75 23.75 0.75 23.75
F4 SE APARTMENT 0.25 0.00 0.25 0.00
F4 NE APARTMENT 3.50 56.50 3.50 56.50
F4 N1 APARTMENT 5.00 59.00 5.00 59.00
F4 N2 APARTMENT 4.25 64.00 4.25 64.00
F4 S1 APARTMENT 2.25 0.00 2.25 0.00
F4 S2 APARTMENT 2.25 0.00 2.25 0.00
M SW APARTMENT 0.50 0.25 0.50 0.25
M NW APARTMENT 1.50 23.25 1.50 23.25
M SE APARTMENT 0.50 0.00 0.50 0.00
M NE APARTMENT 4.25 58.50 4.25 58.50
M N1 APARTMENT 4.50 59.25 4.50 59.25
M N2 APARTMENT 5.25 64.50 5.25 64.50
M S1 APARTMENT 1.00 0.00 1.00 0.00
M S2 APARTMENT 1.25 0.00 1.25 0.00
F6 SW APARTMENT 0.25 0.75 0.25 0.75
F6 NW APARTMENT 1.00 24.25 1.00 24.25
F6 SE APARTMENT 0.50 0.00 0.50 0.00
F6 NE APARTMENT 3.75 62.00 3.75 62.00
F6 N1 APARTMENT 6.00 59.25 6.00 59.25
F6 N2 APARTMENT 4.50 65.00 4.50 65.00
F6 S1 APARTMENT 1.00 0.00 1.00 0.00
F6 S2 APARTMENT 0.75 0.00 0.75 0.00
F7 SW APARTMENT 0.50 1.25 0.50 1.25
F7 NW APARTMENT 0.75 25.00 0.75 25.00
F7 SE APARTMENT 0.00 0.00 0.00 0.00
F7 NE APARTMENT 2.75 63.25 2.75 63.25
F7 N1 APARTMENT 7.50 59.75 7.50 59.75
F7 N2 APARTMENT 6.50 62.25 6.50 62.25
F7 S1 APARTMENT 2.00 0.00 2.00 0.00
F7 S2 APARTMENT 2.25 0.00 2.25 0.00
F8 SW APARTMENT 0.00 1.25 0.00 1.25
F8 NW APARTMENT 1.25 25.50 1.25 25.50
F8 SE APARTMENT 0.00 0.00 0.00 0.00
F8 NE APARTMENT 2.25 64.75 2.25 64.75
F8 N1 APARTMENT 4.25 59.25 4.25 59.25
F8 N2 APARTMENT 4.00 62.25 4.00 62.25
F8 S1 APARTMENT 2.00 0.00 2.00 0.00
F8 S2 APARTMENT 1.75 0.00 1.75 0.00
F9 SW APARTMENT 0.25 2.25 0.25 2.25
F9 NW APARTMENT 1.00 24.25 1.00 24.25
F9 SE APARTMENT 0.00 0.00 0.00 0.00
F9 NE APARTMENT 2.25 48.00 2.25 48.00
F9 N1 APARTMENT 5.50 53.00 5.50 53.00
F9 N2 APARTMENT 5.25 54.75 5.25 54.75
F9 S1 APARTMENT 0.75 0.00 0.75 0.00
F9 S2 APARTMENT 0.75 0.00 0.75 0.00
T SW APARTMENT 0.00 0.00 0.00 0.00
T NW APARTMENT 0.00 22.75 0.00 22.75
T SE APARTMENT 0.00 0.00 0.00 0.00
T NE APARTMENT 0.75 35.75 0.75 35.75
T N1 APARTMENT 3.75 35.75 3.75 35.75
T N2 APARTMENT 3.25 34.50 3.25 34.50
T S1 APARTMENT 0.75 0.00 0.75 0.00
T S2 APARTMENT 0.00 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
Facility 157.75 86.75 155.00 86.75
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:13

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.353 0.153 0.000 0.290
G NW APARTMENT 1.71 2.50 268.96 0.353 0.153 0.000 0.282
OFFICE 0.94 1.00 268.96 0.519 0.181 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.353 0.153 0.000 0.282
G N1 APARTMENT 1.71 2.50 268.96 0.353 0.092 0.000 0.275
G N2 APARTMENT 1.71 2.50 268.97 0.353 0.092 0.000 0.274
G S1 APARTMENT 1.71 2.50 268.96 0.353 0.092 0.000 0.287
G S2 APARTMENT 1.71 2.50 268.97 0.353 0.092 0.000 0.288
F2 SW APARTMENT 1.71 2.50 268.96 0.353 0.220 0.000 0.329
F2 NW APARTMENT 1.71 2.50 268.96 0.353 0.220 0.000 0.323
F2 SE APARTMENT 1.71 2.50 268.96 0.354 0.220 0.000 0.331
F2 NE APARTMENT 1.71 2.50 268.96 0.353 0.220 0.000 0.323
F2 N1 APARTMENT 1.71 2.50 268.96 0.353 0.133 0.000 0.317
F2 N2 APARTMENT 1.71 2.50 268.97 0.353 0.133 0.000 0.317
F2 S1 APARTMENT 1.71 2.50 268.96 0.354 0.133 0.000 0.327
F2 S2 APARTMENT 1.71 2.50 268.97 0.354 0.133 0.000 0.327
F3 SW APARTMENT 1.71 2.50 268.96 0.354 0.261 0.000 0.353
F3 NW APARTMENT 1.71 2.50 268.96 0.353 0.261 0.000 0.349
F3 SE APARTMENT 1.71 2.50 268.96 0.353 0.261 0.000 0.353
F3 NE APARTMENT 1.71 2.50 268.96 0.353 0.261 0.000 0.348
F3 N1 APARTMENT 1.71 2.50 268.96 0.353 0.157 0.000 0.344
F3 N2 APARTMENT 1.71 2.50 268.97 0.353 0.157 0.000 0.344
F3 S1 APARTMENT 1.71 2.50 268.96 0.354 0.157 0.000 0.351
F3 S2 APARTMENT 1.71 2.50 268.97 0.354 0.157 0.000 0.351
F4 SW APARTMENT 1.71 2.50 268.96 0.353 0.292 0.000 0.356
F4 NW APARTMENT 1.71 2.50 268.96 0.353 0.291 0.000 0.354
F4 SE APARTMENT 1.71 2.50 268.96 0.353 0.292 0.000 0.357
F4 NE APARTMENT 1.71 2.50 268.96 0.353 0.291 0.000 0.354
F4 N1 APARTMENT 1.71 2.50 268.96 0.353 0.176 0.000 0.350
F4 N2 APARTMENT 1.71 2.50 268.97 0.353 0.176 0.000 0.350
F4 S1 APARTMENT 1.71 2.50 268.96 0.354 0.176 0.000 0.355
F4 S2 APARTMENT 1.71 2.50 268.97 0.354 0.176 0.000 0.355
M SW APARTMENT 1.71 2.50 268.96 0.353 0.317 0.000 0.370
M NW APARTMENT 1.71 2.50 268.96 0.353 0.317 0.000 0.369
M SE APARTMENT 1.71 2.50 268.96 0.353 0.317 0.000 0.371
M NE APARTMENT 1.71 2.50 268.96 0.353 0.316 0.000 0.368
M N1 APARTMENT 1.71 2.50 268.96 0.353 0.191 0.000 0.365
M N2 APARTMENT 1.71 2.50 268.97 0.353 0.191 0.000 0.365
M S1 APARTMENT 1.71 2.50 268.96 0.354 0.191 0.000 0.369
M S2 APARTMENT 1.71 2.50 268.97 0.354 0.191 0.000 0.369
F6 SW APARTMENT 1.71 2.50 268.96 0.353 0.339 0.000 0.382
F6 NW APARTMENT 1.71 2.50 268.96 0.353 0.338 0.000 0.381
F6 SE APARTMENT 1.71 2.50 268.96 0.353 0.338 0.000 0.382
F6 NE APARTMENT 1.71 2.50 268.96 0.353 0.338 0.000 0.380
F6 N1 APARTMENT 1.71 2.50 268.96 0.353 0.204 0.000 0.376
F6 N2 APARTMENT 1.71 2.50 268.97 0.353 0.204 0.000 0.376
F6 S1 APARTMENT 1.71 2.50 268.96 0.354 0.204 0.000 0.381
F6 S2 APARTMENT 1.71 2.50 268.97 0.354 0.204 0.000 0.381
F7 SW APARTMENT 1.71 2.50 268.96 0.353 0.358 0.000 0.392
F7 NW APARTMENT 1.71 2.50 268.96 0.353 0.357 0.000 0.391
F7 SE APARTMENT 1.71 2.50 268.96 0.353 0.358 0.000 0.392
F7 NE APARTMENT 1.71 2.50 268.96 0.353 0.357 0.000 0.390
F7 N1 APARTMENT 1.71 2.50 268.96 0.353 0.216 0.000 0.386
F7 N2 APARTMENT 1.71 2.50 268.97 0.353 0.216 0.000 0.386
F7 S1 APARTMENT 1.71 2.50 268.96 0.354 0.216 0.000 0.390
F7 S2 APARTMENT 1.71 2.50 268.97 0.354 0.216 0.000 0.390
F8 SW APARTMENT 1.71 2.50 268.96 0.353 0.375 0.000 0.403
F8 NW APARTMENT 1.71 2.50 268.96 0.353 0.375 0.000 0.402
F8 SE APARTMENT 1.71 2.50 268.96 0.353 0.375 0.000 0.403
F8 NE APARTMENT 1.71 2.50 268.96 0.353 0.375 0.000 0.401
F8 N1 APARTMENT 1.71 2.50 268.96 0.353 0.226 0.000 0.397
F8 N2 APARTMENT 1.71 2.50 268.97 0.353 0.226 0.000 0.397
F8 S1 APARTMENT 1.71 2.50 268.96 0.354 0.226 0.000 0.401
F8 S2 APARTMENT 1.71 2.50 268.97 0.354 0.226 0.000 0.401
F9 SW APARTMENT 1.71 2.50 268.96 0.353 0.391 0.000 0.412
F9 NW APARTMENT 1.71 2.50 268.96 0.353 0.390 0.000 0.411
F9 SE APARTMENT 1.71 2.50 268.96 0.353 0.391 0.000 0.412
F9 NE APARTMENT 1.71 2.50 268.96 0.353 0.390 0.000 0.410
F9 N1 APARTMENT 1.71 2.50 268.96 0.353 0.235 0.000 0.406
F9 N2 APARTMENT 1.71 2.50 268.97 0.353 0.235 0.000 0.406
F9 S1 APARTMENT 1.71 2.50 268.96 0.353 0.236 0.000 0.410
F9 S2 APARTMENT 1.71 2.50 268.97 0.353 0.236 0.000 0.410
T SW APARTMENT 1.71 2.50 268.96 0.353 0.405 0.000 0.419
T NW APARTMENT 1.71 2.50 268.96 0.353 0.405 0.000 0.419
T SE APARTMENT 1.71 2.50 268.96 0.353 0.405 0.000 0.420
T NE APARTMENT 1.71 2.50 268.96 0.353 0.405 0.000 0.419
T N1 APARTMENT 1.71 2.50 268.96 0.353 0.244 0.000 0.415
T N2 APARTMENT 1.71 2.50 268.97 0.353 0.244 0.000 0.415
T S1 APARTMENT 1.71 2.50 268.96 0.353 0.244 0.000 0.418
T S2 APARTMENT 1.71 2.50 268.97 0.353 0.244 0.000 0.418
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
OFFICE 0.94 1.00 268.96 0.501 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F2 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F2 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F2 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F3 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F3 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F3 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F4 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F4 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F4 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F6 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F6 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F6 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F7 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F7 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F7 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F8 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F8 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F8 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F9 SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
F9 S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
F9 S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.96 0.341 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:13

Surfaces by Class

Total Outdoors
Wall 420 140
Floor 90 9
Roof 90 9
Internal Mass 80 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 140 140
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 80
Conditioned Zones 80
Unconditioned Zones 10
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 4156
Defaulted Fields 814
Fields with Defaults 11184
Autosized Fields 1293
Autosizable Fields 1630
Autocalculated Fields 907
Autocalculatable Fields 1710



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2015-09-09 19:12:13

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 2745.02 55719.61 30-MAY-05:00 165462.52 19-JUL-17:15
Electricity:Building 1433.88 25760.85 01-JAN-03:15 70162.48 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity 296.56 6715.87 01-JAN-00:15 14401.37 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 242.55 5824.91 01-JAN-00:15 11484.27 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:OFFICE 39.38 663.42 01-JAN-00:15 2934.49 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 29.88 469.18 01-JAN-00:15 2345.88 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:G CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F2 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F2 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F3 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F3 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F4 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F4 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:M SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M CORRIDOR 32.88 1042.61 01-JAN-00:15 1042.61 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 32.88 1042.61 01-JAN-00:15 1042.61 01-JAN-00:15
Electricity:Zone:F6 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F6 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F7 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F7 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F8 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F8 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F9 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F9 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:T SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T CORRIDOR 179.47 1701.70 01-JAN-00:15 10868.20 01-JAN-07:15
InteriorLights:Electricity:Zone:T CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 54.01 890.97 01-JAN-00:15 2917.11 01-JAN-19:15
InteriorEquipment:Electricity 1137.32 19044.98 01-JAN-03:15 57142.09 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 1137.32 19044.98 01-JAN-03:15 57142.09 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 9.50 194.24 01-JAN-00:15 588.62 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T CORRIDOR 163.03 1180.40 01-JAN-00:15 10346.90 01-JAN-07:15
Fans:Electricity 662.42 21005.32 11-FEB-17:15 21005.32 01-JAN-00:15
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Electricity:HVAC 1077.71 21666.56 04-MAY-03:00 92023.82 19-JUL-16:15
ElectricityProduced:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityProduced:HVAC 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricityProduced 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 2745.02 55719.61 30-MAY-05:00 165462.52 19-JUL-17:15
ElectricityPurchased:Plant 2745.02 55719.61 30-MAY-05:00 165462.52 19-JUL-17:15
Cogeneration:ElectricityPurchased 2745.02 55719.61 30-MAY-05:00 165462.52 19-JUL-17:15
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 2745.02 55719.61 30-MAY-05:00 165462.52 19-JUL-17:15
ElectricityNet:Plant 2745.02 55719.61 30-MAY-05:00 165462.52 19-JUL-17:15
Cogeneration:ElectricityNet 2745.02 55719.61 30-MAY-05:00 165462.52 19-JUL-17:15
ExteriorLights:Electricity 162.79 0.00 01-JAN-08:00 10364.00 01-JAN-00:15
General:ExteriorLights:Electricity 162.79 0.00 01-JAN-08:00 10364.00 01-JAN-00:15
General:Fans:Electricity 662.42 21005.32 11-FEB-17:15 21005.32 01-JAN-00:15
Cooling:Electricity 235.55 0.00 01-JAN-00:15 69138.10 31-JUL-15:15
Heating:Electricity 143.57 0.00 21-FEB-13:45 63192.47 15-FEB-02:00
Electricity:Plant 70.63 36.93 04-APR-19:45 4605.14 18-JUL-16:00
HeatRejection:Electricity 9.60 0.00 01-JAN-00:15 2645.30 18-JUL-16:00
Boiler Parasitic:Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Pumps:Electricity 61.04 36.93 04-APR-19:45 1959.84 01-JAN-00:15
WIRED_LTG_ELECTRICITY 0.44 0.00 01-JAN-00:15 21.60 01-JAN-19:30
WIRED_INT_EQUIP 979.40 1018.50 01-JAN-00:15 10185.00 01-JAN-07:15


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 1632.57 2357.00 19-JAN-24:00 258366.00 20-DEC-08:00
Gas:Plant 1632.57 2357.00 19-JAN-24:00 258366.00 20-DEC-08:00
WaterSystems:Gas 1149.45 2357.00 01-JAN-00:15 80018.31 11-FEB-08:00
Water Heater:WaterSystems:Gas 1149.45 2357.00 01-JAN-00:15 80018.31 11-FEB-08:00
Heating:Gas 483.12 0.00 15-JAN-16:00 211963.52 15-FEB-02:30
Boiler:Heating:Gas 483.12 0.00 15-JAN-16:00 211963.52 15-FEB-02:30


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
PlantLoopCoolingDemand:Facility 960.08 0.00 01-JAN-00:15 318244.52 19-JUL-16:15
PlantLoopCoolingDemand:HVAC 960.08 0.00 01-JAN-00:15 318244.52 19-JUL-16:15
CoolingCoils:PlantLoopCoolingDemand 960.08 0.00 01-JAN-00:15 318244.52 19-JUL-16:15


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 5524.92 0.00 01-JAN-02:15 0.00 17-JUL-17:15
Water:Plant 5524.92 0.00 01-JAN-02:15 0.00 17-JUL-17:15
WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
MainsWater:Facility 5524.92 0.00 01-JAN-02:15 0.00 17-JUL-17:15
MainsWater:Plant 5524.92 0.00 01-JAN-02:15 0.00 17-JUL-17:15
WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
sub cat:WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
sub cat:WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
HeatRejection:Water 746.40 0.00 01-JAN-00:15 0.00 17-JUL-16:00
HeatRejection:MainsWater 746.40 0.00 01-JAN-00:15 0.00 17-JUL-16:00


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 1295.88 491.11 05-AUG-01:15 193777.68 15-FEB-06:15
PlantLoopHeatingDemand:Plant 894.38 491.11 05-AUG-01:15 58046.59 09-FEB-07:30
WaterSystems:PlantLoopHeatingDemand 894.38 491.11 05-AUG-01:15 58046.59 09-FEB-07:30
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 3650.46 7088.15 26-OCT-01:15 572209.03 15-FEB-02:15
EnergyTransfer:Building 1122.14 4319.10 10-NOV-17:30 193304.42 09-SEP-15:15
EnergyTransfer:Zone:G SW APARTMENT 12.10 0.01 21-APR-19:30 2928.99 10-SEP-15:30
Heating:EnergyTransfer 356.64 0.00 31-JAN-13:15 191675.41 15-FEB-02:00
Heating:EnergyTransfer:Zone:G SW APARTMENT 4.67 0.00 01-JAN-09:15 1912.16 15-FEB-02:00
Cooling:EnergyTransfer 765.50 0.00 03-JAN-01:00 193304.42 09-SEP-15:15
Cooling:EnergyTransfer:Zone:G SW APARTMENT 7.43 0.00 01-JAN-00:15 2928.99 10-SEP-15:30
EnergyTransfer:Zone:G NW APARTMENT 11.27 0.02 24-APR-01:45 2305.46 24-JUN-18:00
Heating:EnergyTransfer:Zone:G NW APARTMENT 6.33 0.00 15-JAN-16:15 1937.26 15-FEB-02:00
Cooling:EnergyTransfer:Zone:G NW APARTMENT 4.94 0.00 01-JAN-00:15 2305.46 24-JUN-18:00
EnergyTransfer:Zone:OFFICE 19.08 0.01 21-OCT-01:45 3791.43 31-AUG-13:30
Heating:EnergyTransfer:Zone:OFFICE 3.03 0.00 01-JAN-08:45 1699.43 15-FEB-02:00
Cooling:EnergyTransfer:Zone:OFFICE 16.06 0.00 01-JAN-00:15 3791.43 31-AUG-13:30
EnergyTransfer:Zone:G NE APARTMENT 11.07 0.00 22-SEP-19:30 1940.50 15-FEB-02:00
Heating:EnergyTransfer:Zone:G NE APARTMENT 6.24 0.00 15-JAN-17:15 1940.50 15-FEB-02:00
Cooling:EnergyTransfer:Zone:G NE APARTMENT 4.83 0.00 01-JAN-00:15 1616.99 04-JUN-09:30
EnergyTransfer:Zone:G N1 APARTMENT 7.49 0.02 17-AUG-09:45 1221.10 12-DEC-13:15
Heating:EnergyTransfer:Zone:G N1 APARTMENT 3.00 0.00 07-JAN-18:45 1221.10 12-DEC-13:15
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 4.49 0.00 01-JAN-00:15 1018.76 14-JUL-19:00
EnergyTransfer:Zone:G N2 APARTMENT 7.48 0.05 31-OCT-22:15 1221.48 12-DEC-13:15
Heating:EnergyTransfer:Zone:G N2 APARTMENT 3.00 0.00 07-JAN-18:45 1221.48 12-DEC-13:15
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 4.48 0.00 01-JAN-00:15 993.92 14-JUL-19:00
EnergyTransfer:Zone:G S1 APARTMENT 8.71 0.02 30-SEP-20:30 2045.42 31-AUG-12:45
Heating:EnergyTransfer:Zone:G S1 APARTMENT 1.61 0.00 01-JAN-00:15 1275.09 09-NOV-11:15
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 7.09 0.00 01-JAN-00:30 2045.42 31-AUG-12:45
EnergyTransfer:Zone:G S2 APARTMENT 8.78 0.04 03-MAR-22:30 2104.98 31-AUG-12:45
Heating:EnergyTransfer:Zone:G S2 APARTMENT 1.49 0.00 01-JAN-00:15 1196.99 09-NOV-11:15
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 7.29 0.00 01-JAN-00:30 2104.98 31-AUG-12:45
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F2 SW APARTMENT 16.27 0.02 06-NOV-01:15 3705.43 09-SEP-15:15
Heating:EnergyTransfer:Zone:F2 SW APARTMENT 3.80 0.00 01-JAN-00:15 2288.84 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT 12.46 0.00 01-JAN-01:15 3705.43 09-SEP-15:15
EnergyTransfer:Zone:F2 NW APARTMENT 13.25 0.00 30-MAR-19:15 2953.24 24-JUN-18:00
Heating:EnergyTransfer:Zone:F2 NW APARTMENT 5.50 0.00 15-JAN-17:15 2379.64 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT 7.75 0.00 01-JAN-00:15 2953.24 24-JUN-18:00
EnergyTransfer:Zone:F2 SE APARTMENT 16.47 0.02 19-SEP-02:30 3368.03 09-SEP-13:30
Heating:EnergyTransfer:Zone:F2 SE APARTMENT 3.21 0.00 01-JAN-00:15 2199.20 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT 13.26 0.00 01-JAN-01:15 3368.03 09-SEP-13:30
EnergyTransfer:Zone:F2 NE APARTMENT 12.95 0.01 09-NOV-10:45 2384.81 15-FEB-02:00
Heating:EnergyTransfer:Zone:F2 NE APARTMENT 5.38 0.00 15-JAN-16:15 2384.81 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT 7.57 0.00 01-JAN-00:15 2200.91 04-JUN-09:30
EnergyTransfer:Zone:F2 N1 APARTMENT 8.79 0.01 20-JUN-15:30 1438.81 12-DEC-13:15
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT 1.77 0.00 01-JAN-17:15 1438.81 12-DEC-13:15
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT 7.01 0.00 01-JAN-00:15 1395.20 14-JUL-19:00
EnergyTransfer:Zone:F2 N2 APARTMENT 8.77 0.01 04-MAY-09:45 1437.99 12-DEC-13:15
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT 1.78 0.00 01-JAN-17:15 1437.99 12-DEC-13:15
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT 6.99 0.00 01-JAN-00:15 1372.58 14-JUL-19:00
EnergyTransfer:Zone:F2 S1 APARTMENT 12.65 0.07 01-NOV-03:00 2619.35 31-AUG-12:45
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT 1.02 0.00 01-JAN-00:15 1225.54 09-NOV-11:15
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT 11.63 0.00 02-JAN-23:30 2619.35 31-AUG-12:45
EnergyTransfer:Zone:F2 S2 APARTMENT 12.73 0.04 26-OCT-23:00 2643.72 31-AUG-12:45
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT 1.00 0.00 01-JAN-00:15 1183.56 15-FEB-02:15
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT 11.73 0.00 02-JAN-23:30 2643.72 31-AUG-12:45
EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F3 SW APARTMENT 17.30 0.00 23-FEB-14:00 3757.93 09-SEP-15:15
Heating:EnergyTransfer:Zone:F3 SW APARTMENT 3.93 0.00 01-JAN-00:15 2531.86 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT 13.37 0.00 01-JAN-02:15 3757.93 09-SEP-15:15
EnergyTransfer:Zone:F3 NW APARTMENT 13.99 0.02 25-MAY-10:00 3008.65 23-JUN-18:00
Heating:EnergyTransfer:Zone:F3 NW APARTMENT 5.63 0.00 01-JAN-18:45 2632.76 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT 8.36 0.00 01-JAN-00:15 3008.65 23-JUN-18:00
EnergyTransfer:Zone:F3 SE APARTMENT 16.90 0.00 23-OCT-15:00 3395.78 09-SEP-13:30
Heating:EnergyTransfer:Zone:F3 SE APARTMENT 3.76 0.00 01-JAN-00:15 2521.30 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT 13.15 0.00 01-JAN-02:15 3395.78 09-SEP-13:30
EnergyTransfer:Zone:F3 NE APARTMENT 13.68 0.03 10-JUL-08:30 2638.07 15-FEB-02:00
Heating:EnergyTransfer:Zone:F3 NE APARTMENT 5.52 0.00 01-JAN-09:30 2638.07 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT 8.16 0.00 01-JAN-00:15 2266.13 04-JUN-09:30
EnergyTransfer:Zone:F3 N1 APARTMENT 9.48 0.01 21-SEP-12:00 1621.64 12-DEC-13:15
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT 1.72 0.00 01-JAN-08:00 1621.64 12-DEC-13:15
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT 7.76 0.00 01-JAN-00:15 1458.77 22-JUN-16:15
EnergyTransfer:Zone:F3 N2 APARTMENT 9.46 0.01 04-OCT-09:30 1621.07 12-DEC-13:15
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT 1.72 0.00 01-JAN-08:00 1621.07 12-DEC-13:15
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT 7.74 0.00 01-JAN-00:15 1448.55 22-JUN-16:15
EnergyTransfer:Zone:F3 S1 APARTMENT 13.92 0.01 12-DEC-00:45 2709.16 30-AUG-14:00
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT 1.02 0.00 01-JAN-00:15 1346.46 12-DEC-13:15
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT 12.90 0.00 03-JAN-00:30 2709.16 30-AUG-14:00
EnergyTransfer:Zone:F3 S2 APARTMENT 13.92 0.04 09-FEB-19:45 2721.03 30-AUG-14:00
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT 1.02 0.00 01-JAN-00:15 1343.94 12-DEC-13:15
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT 12.91 0.00 03-JAN-00:30 2721.03 30-AUG-14:00
EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F4 SW APARTMENT 17.69 0.02 01-MAR-14:00 3792.32 09-SEP-15:30
Heating:EnergyTransfer:Zone:F4 SW APARTMENT 4.25 0.00 01-JAN-00:15 2764.33 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT 13.45 0.00 01-JAN-02:15 3792.32 09-SEP-15:30
EnergyTransfer:Zone:F4 NW APARTMENT 14.43 0.03 21-FEB-13:00 3046.96 23-JUN-17:45
Heating:EnergyTransfer:Zone:F4 NW APARTMENT 6.00 0.00 01-JAN-18:30 2865.76 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT 8.43 0.00 01-JAN-00:15 3046.96 23-JUN-17:45
EnergyTransfer:Zone:F4 SE APARTMENT 17.21 0.04 30-DEC-11:45 3432.39 09-SEP-13:30
Heating:EnergyTransfer:Zone:F4 SE APARTMENT 4.16 0.00 01-JAN-00:15 2768.18 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT 13.05 0.00 01-JAN-02:15 3432.39 09-SEP-13:30
EnergyTransfer:Zone:F4 NE APARTMENT 14.13 0.00 27-JUN-18:15 2871.08 15-FEB-02:00
Heating:EnergyTransfer:Zone:F4 NE APARTMENT 5.89 0.00 01-JAN-09:30 2871.08 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT 8.25 0.00 01-JAN-00:15 2300.00 04-JUN-09:30
EnergyTransfer:Zone:F4 N1 APARTMENT 9.76 0.01 07-SEP-12:45 1554.71 15-FEB-02:00
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT 1.83 0.00 01-JAN-07:15 1554.71 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT 7.93 0.00 01-JAN-00:15 1511.68 22-JUN-16:15
EnergyTransfer:Zone:F4 N2 APARTMENT 9.74 0.01 18-JUN-18:15 1555.07 15-FEB-02:00
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT 1.83 0.00 01-JAN-07:15 1555.07 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT 7.90 0.00 01-JAN-00:15 1488.15 22-JUN-16:15
EnergyTransfer:Zone:F4 S1 APARTMENT 14.29 0.04 11-JUL-14:15 2729.88 31-AUG-13:00
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT 1.11 0.00 01-JAN-00:15 1434.66 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT 13.18 0.00 03-JAN-01:00 2729.88 31-AUG-13:00
EnergyTransfer:Zone:F4 S2 APARTMENT 14.27 0.07 27-OCT-01:45 2741.59 31-AUG-13:00
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT 1.11 0.00 01-JAN-00:15 1434.63 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT 13.16 0.00 03-JAN-01:00 2741.59 31-AUG-13:00
EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M SW APARTMENT 18.01 0.01 17-NOV-20:00 3841.83 09-SEP-15:30
Heating:EnergyTransfer:Zone:M SW APARTMENT 4.55 0.00 01-JAN-00:15 2953.29 15-FEB-02:00
Cooling:EnergyTransfer:Zone:M SW APARTMENT 13.46 0.00 01-JAN-02:15 3841.83 09-SEP-15:30
EnergyTransfer:Zone:M NW APARTMENT 14.81 0.03 20-SEP-08:45 3105.73 23-JUN-17:45
Heating:EnergyTransfer:Zone:M NW APARTMENT 6.31 0.00 01-JAN-18:30 3050.70 15-FEB-02:00
Cooling:EnergyTransfer:Zone:M NW APARTMENT 8.49 0.00 01-JAN-00:15 3105.73 23-JUN-17:45
EnergyTransfer:Zone:M SE APARTMENT 17.52 0.03 01-NOV-15:00 3484.75 09-SEP-13:30
Heating:EnergyTransfer:Zone:M SE APARTMENT 4.48 0.00 01-JAN-00:15 2959.38 15-FEB-02:00
Cooling:EnergyTransfer:Zone:M SE APARTMENT 13.04 0.00 01-JAN-02:15 3484.75 09-SEP-13:30
EnergyTransfer:Zone:M NE APARTMENT 14.52 0.02 10-JUL-21:00 3056.03 15-FEB-02:00
Heating:EnergyTransfer:Zone:M NE APARTMENT 6.20 0.00 01-JAN-09:15 3056.03 15-FEB-02:00
Cooling:EnergyTransfer:Zone:M NE APARTMENT 8.32 0.00 01-JAN-00:15 2341.86 04-JUN-09:30
EnergyTransfer:Zone:M N1 APARTMENT 10.01 0.02 26-JUN-10:45 1657.82 15-FEB-02:00
Heating:EnergyTransfer:Zone:M N1 APARTMENT 1.93 0.00 01-JAN-07:00 1657.82 15-FEB-02:00
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 8.08 0.00 01-JAN-00:15 1552.44 22-JUN-16:15
EnergyTransfer:Zone:M N2 APARTMENT 9.99 0.01 08-AUG-10:15 1658.17 15-FEB-02:00
Heating:EnergyTransfer:Zone:M N2 APARTMENT 1.94 0.00 01-JAN-07:00 1658.17 15-FEB-02:00
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 8.05 0.00 01-JAN-00:15 1539.97 22-JUN-15:30
EnergyTransfer:Zone:M S1 APARTMENT 14.52 0.02 04-DEC-08:00 2768.75 31-AUG-13:00
Heating:EnergyTransfer:Zone:M S1 APARTMENT 1.21 0.00 01-JAN-00:15 1545.60 15-FEB-02:00
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 13.31 0.00 03-JAN-00:45 2768.75 31-AUG-13:00
EnergyTransfer:Zone:M S2 APARTMENT 14.49 0.03 28-JUN-15:15 2780.13 31-AUG-13:00
Heating:EnergyTransfer:Zone:M S2 APARTMENT 1.21 0.00 01-JAN-00:15 1545.84 15-FEB-02:00
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 13.28 0.00 03-JAN-01:00 2780.13 31-AUG-13:00
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F6 SW APARTMENT 17.87 0.08 22-MAR-01:45 3822.68 09-SEP-15:15
Heating:EnergyTransfer:Zone:F6 SW APARTMENT 5.18 0.00 01-JAN-00:15 3167.00 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT 12.70 0.00 01-JAN-02:00 3822.68 09-SEP-15:15
EnergyTransfer:Zone:F6 NW APARTMENT 15.06 0.03 13-OCT-11:45 3261.22 15-FEB-02:00
Heating:EnergyTransfer:Zone:F6 NW APARTMENT 7.10 0.00 01-JAN-18:45 3261.22 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT 7.96 0.00 01-JAN-00:15 3088.04 23-JUN-17:45
EnergyTransfer:Zone:F6 SE APARTMENT 17.40 0.02 28-JUN-02:30 3472.69 09-SEP-13:30
Heating:EnergyTransfer:Zone:F6 SE APARTMENT 5.11 0.00 01-JAN-00:15 3173.41 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT 12.29 0.00 01-JAN-01:45 3472.69 09-SEP-13:30
EnergyTransfer:Zone:F6 NE APARTMENT 14.80 0.00 09-NOV-16:15 3266.62 15-FEB-02:00
Heating:EnergyTransfer:Zone:F6 NE APARTMENT 6.99 0.00 01-JAN-09:30 3266.62 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT 7.81 0.00 01-JAN-00:15 2315.66 04-JUN-09:30
EnergyTransfer:Zone:F6 N1 APARTMENT 9.85 0.01 17-SEP-19:45 1793.76 15-FEB-02:00
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT 2.33 0.00 01-JAN-07:15 1793.76 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT 7.53 0.00 01-JAN-00:15 1528.74 26-AUG-18:15
EnergyTransfer:Zone:F6 N2 APARTMENT 9.83 0.00 04-AUG-20:00 1794.13 15-FEB-02:00
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT 2.33 0.00 01-JAN-07:15 1794.13 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT 7.50 0.00 01-JAN-00:15 1520.74 22-JUN-15:30
EnergyTransfer:Zone:F6 S1 APARTMENT 14.01 0.02 12-DEC-20:45 2741.62 31-AUG-13:00
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT 1.46 0.00 01-JAN-00:15 1676.74 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT 12.54 0.00 03-JAN-00:15 2741.62 31-AUG-13:00
EnergyTransfer:Zone:F6 S2 APARTMENT 13.98 0.01 14-JAN-23:45 2752.96 31-AUG-13:00
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT 1.47 0.00 01-JAN-00:15 1677.03 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT 12.51 0.00 03-JAN-00:15 2752.96 31-AUG-13:00
EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F7 SW APARTMENT 17.90 0.02 01-MAR-20:45 3824.73 09-SEP-15:15
Heating:EnergyTransfer:Zone:F7 SW APARTMENT 5.70 0.00 01-JAN-00:15 3345.78 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT 12.20 0.00 01-JAN-01:45 3824.73 09-SEP-15:15
EnergyTransfer:Zone:F7 NW APARTMENT 15.35 0.02 27-OCT-07:00 3435.28 15-FEB-02:00
Heating:EnergyTransfer:Zone:F7 NW APARTMENT 7.72 0.00 01-JAN-18:45 3435.28 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT 7.63 0.00 01-JAN-00:15 3091.99 23-JUN-17:45
EnergyTransfer:Zone:F7 SE APARTMENT 17.45 0.01 31-DEC-02:00 3478.10 09-SEP-13:30
Heating:EnergyTransfer:Zone:F7 SE APARTMENT 5.64 0.00 01-JAN-00:15 3352.05 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT 11.81 0.00 01-JAN-01:30 3478.10 09-SEP-13:30
EnergyTransfer:Zone:F7 NE APARTMENT 15.10 0.02 14-APR-01:15 3440.74 15-FEB-02:00
Heating:EnergyTransfer:Zone:F7 NE APARTMENT 7.60 0.00 01-JAN-09:30 3440.74 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT 7.49 0.00 01-JAN-00:15 2311.69 04-JUN-09:30
EnergyTransfer:Zone:F7 N1 APARTMENT 9.83 0.01 22-MAY-13:15 1903.97 15-FEB-02:00
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT 2.64 0.00 01-JAN-07:30 1903.97 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT 7.19 0.00 01-JAN-00:15 1532.11 26-AUG-18:15
EnergyTransfer:Zone:F7 N2 APARTMENT 9.81 0.02 11-SEP-10:45 1904.34 15-FEB-02:00
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT 2.64 0.00 01-JAN-07:30 1904.34 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT 7.17 0.00 01-JAN-00:15 1521.16 26-AUG-18:15
EnergyTransfer:Zone:F7 S1 APARTMENT 13.73 0.03 26-OCT-22:45 2736.40 31-AUG-13:00
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT 1.69 0.00 01-JAN-00:15 1788.98 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT 12.04 0.00 02-JAN-23:30 2736.40 31-AUG-13:00
EnergyTransfer:Zone:F7 S2 APARTMENT 13.70 0.02 09-NOV-19:45 2747.71 31-AUG-13:00
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT 1.69 0.00 01-JAN-00:15 1789.31 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT 12.01 0.00 02-JAN-23:30 2747.71 31-AUG-13:00
EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F8 SW APARTMENT 18.02 0.03 16-MAR-00:15 3835.88 09-SEP-15:15
Heating:EnergyTransfer:Zone:F8 SW APARTMENT 6.22 0.00 01-JAN-00:15 3514.18 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT 11.80 0.00 01-JAN-01:15 3835.88 09-SEP-15:15
EnergyTransfer:Zone:F8 NW APARTMENT 15.70 0.01 18-JUN-13:30 3597.64 15-FEB-02:00
Heating:EnergyTransfer:Zone:F8 NW APARTMENT 8.31 0.00 01-JAN-19:00 3597.64 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT 7.38 0.00 01-JAN-00:15 3100.42 23-JUN-18:00
EnergyTransfer:Zone:F8 SE APARTMENT 17.59 0.02 06-JUN-04:15 3520.26 15-FEB-02:00
Heating:EnergyTransfer:Zone:F8 SE APARTMENT 6.17 0.00 01-JAN-00:15 3520.26 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT 11.42 0.00 01-JAN-01:15 3485.81 09-SEP-13:30
EnergyTransfer:Zone:F8 NE APARTMENT 15.46 0.09 06-JUL-08:15 3603.17 15-FEB-02:00
Heating:EnergyTransfer:Zone:F8 NE APARTMENT 8.20 0.00 01-JAN-10:00 3603.17 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT 7.26 0.00 01-JAN-00:15 2340.04 04-JUN-09:45
EnergyTransfer:Zone:F8 N1 APARTMENT 9.89 0.01 02-DEC-20:30 2008.84 15-FEB-02:00
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT 2.96 0.00 01-JAN-17:30 2008.84 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT 6.92 0.00 01-JAN-00:15 1560.97 04-JUN-09:45
EnergyTransfer:Zone:F8 N2 APARTMENT 9.87 0.00 28-JUN-15:30 2009.22 15-FEB-02:00
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT 2.97 0.00 01-JAN-17:30 2009.22 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT 6.90 0.00 01-JAN-00:15 1548.72 04-JUN-09:45
EnergyTransfer:Zone:F8 S1 APARTMENT 13.53 0.01 17-SEP-20:45 2741.31 31-AUG-13:00
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT 1.92 0.00 01-JAN-00:15 1899.19 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT 11.60 0.00 02-JAN-23:00 2741.31 31-AUG-13:00
EnergyTransfer:Zone:F8 S2 APARTMENT 13.50 0.01 15-JAN-15:15 2752.65 31-AUG-13:00
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT 1.93 0.00 01-JAN-00:15 1899.50 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT 11.57 0.00 02-JAN-23:00 2752.65 31-AUG-13:00
EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F9 SW APARTMENT 18.52 0.00 29-OCT-18:30 3916.68 09-SEP-15:30
Heating:EnergyTransfer:Zone:F9 SW APARTMENT 7.17 0.00 01-JAN-00:15 3748.44 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT 11.35 0.00 01-JAN-00:30 3916.68 09-SEP-15:30
EnergyTransfer:Zone:F9 NW APARTMENT 16.56 0.02 29-APR-04:15 3815.60 15-FEB-02:00
Heating:EnergyTransfer:Zone:F9 NW APARTMENT 9.40 0.00 15-JAN-17:30 3815.60 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT 7.16 0.00 01-JAN-00:15 3191.59 23-JUN-18:00
EnergyTransfer:Zone:F9 SE APARTMENT 18.07 0.02 30-OCT-11:45 3754.35 15-FEB-02:00
Heating:EnergyTransfer:Zone:F9 SE APARTMENT 7.11 0.00 01-JAN-00:15 3754.35 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT 10.96 0.00 01-JAN-00:30 3512.99 09-SEP-13:45
EnergyTransfer:Zone:F9 NE APARTMENT 16.30 0.01 18-OCT-12:30 3821.17 15-FEB-02:00
Heating:EnergyTransfer:Zone:F9 NE APARTMENT 9.26 0.00 15-JAN-17:30 3821.17 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT 7.04 0.00 01-JAN-00:15 2451.65 04-JUN-09:45
EnergyTransfer:Zone:F9 N1 APARTMENT 10.23 0.05 10-JUN-10:30 2167.72 15-FEB-02:00
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT 3.65 0.00 01-JAN-18:00 2167.72 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT 6.58 0.00 01-JAN-00:15 1598.07 24-JUN-21:00
EnergyTransfer:Zone:F9 N2 APARTMENT 10.22 0.04 07-JUN-13:00 2168.11 15-FEB-02:00
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT 3.66 0.00 01-JAN-18:00 2168.11 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT 6.56 0.00 01-JAN-00:15 1597.94 04-JUN-09:45
EnergyTransfer:Zone:F9 S1 APARTMENT 13.41 0.05 20-FEB-21:45 2800.09 31-AUG-13:15
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT 2.41 0.00 01-JAN-00:15 2077.59 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT 11.00 0.00 01-JAN-04:00 2800.09 31-AUG-13:15
EnergyTransfer:Zone:F9 S2 APARTMENT 13.39 0.15 08-NOV-12:00 2812.63 31-AUG-13:15
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT 2.42 0.00 01-JAN-00:15 2077.88 15-FEB-02:00
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT 10.97 0.00 01-JAN-04:00 2812.63 31-AUG-13:15
EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:T SW APARTMENT 23.39 0.02 04-MAY-05:45 4663.18 17-JUL-16:15
Heating:EnergyTransfer:Zone:T SW APARTMENT 11.75 0.00 01-JAN-09:15 4291.46 15-FEB-02:00
Cooling:EnergyTransfer:Zone:T SW APARTMENT 11.64 0.00 01-JAN-00:15 4663.18 17-JUL-16:15
EnergyTransfer:Zone:T NW APARTMENT 21.19 0.03 19-JUN-18:45 4310.17 15-FEB-02:00
Heating:EnergyTransfer:Zone:T NW APARTMENT 13.65 0.00 15-JAN-18:45 4310.17 15-FEB-02:00
Cooling:EnergyTransfer:Zone:T NW APARTMENT 7.53 0.00 01-JAN-00:15 3888.91 15-JUL-17:15
EnergyTransfer:Zone:T SE APARTMENT 22.52 0.01 10-OCT-00:30 4294.19 15-FEB-02:00
Heating:EnergyTransfer:Zone:T SE APARTMENT 11.50 0.00 01-JAN-08:45 4294.19 15-FEB-02:00
Cooling:EnergyTransfer:Zone:T SE APARTMENT 11.03 0.00 01-JAN-00:15 4179.51 09-SEP-13:15
EnergyTransfer:Zone:T NE APARTMENT 20.41 0.00 28-SEP-03:15 4312.75 15-FEB-02:00
Heating:EnergyTransfer:Zone:T NE APARTMENT 13.27 0.00 15-JAN-18:15 4312.75 15-FEB-02:00
Cooling:EnergyTransfer:Zone:T NE APARTMENT 7.14 0.00 01-JAN-00:15 3061.83 04-JUN-09:45
EnergyTransfer:Zone:T N1 APARTMENT 13.10 0.04 12-DEC-16:45 2627.86 15-FEB-02:00
Heating:EnergyTransfer:Zone:T N1 APARTMENT 6.86 0.00 15-JAN-16:15 2627.86 15-FEB-02:00
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 6.24 0.00 01-JAN-00:15 2258.43 24-JUN-19:15
EnergyTransfer:Zone:T N2 APARTMENT 13.08 0.03 08-NOV-14:45 2628.09 15-FEB-02:00
Heating:EnergyTransfer:Zone:T N2 APARTMENT 6.88 0.00 15-JAN-16:15 2628.09 15-FEB-02:00
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 6.21 0.00 01-JAN-00:15 2251.47 24-JUN-19:15
EnergyTransfer:Zone:T S1 APARTMENT 15.33 0.01 06-APR-23:45 3621.78 10-SEP-13:15
Heating:EnergyTransfer:Zone:T S1 APARTMENT 5.26 0.00 01-JAN-08:45 2596.64 15-FEB-02:00
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 10.07 0.00 01-JAN-00:15 3621.78 10-SEP-13:15
EnergyTransfer:Zone:T S2 APARTMENT 15.33 0.01 14-NOV-13:45 3634.20 10-SEP-13:15
Heating:EnergyTransfer:Zone:T S2 APARTMENT 5.28 0.00 01-JAN-08:45 2596.82 15-FEB-02:00
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 10.05 0.00 01-JAN-00:15 3634.20 10-SEP-13:15
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Plant 1256.27 491.11 05-AUG-01:15 194701.58 15-FEB-06:15
WaterSystems:EnergyTransfer 894.38 491.11 05-AUG-01:15 58040.65 09-FEB-07:30
sub cat:WaterSystems:EnergyTransfer 894.38 491.11 05-AUG-01:15 58040.65 09-FEB-07:30
EnergyTransfer:HVAC 1272.05 0.00 04-APR-19:45 249587.41 19-JUL-16:15
CoolingCoils:EnergyTransfer 747.18 0.00 01-JAN-00:15 249587.41 19-JUL-16:15
HeatingCoils:EnergyTransfer 524.88 0.00 21-FEB-13:45 222620.38 15-FEB-02:00
PlantLoopHeatingDemand:HVAC 401.49 0.00 21-FEB-13:45 161111.39 15-FEB-02:00
HeatingCoils:PlantLoopHeatingDemand 401.49 0.00 21-FEB-13:45 161111.39 15-FEB-02:00
Boilers:EnergyTransfer 361.89 0.00 15-JAN-16:00 158972.64 15-FEB-02:30



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:13

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 4.667 -7.431 0.000 0.000 3.846 1.087 12.213 18.824 0.000 0.198 0.000 0.000 -10.392 0.000 -8.269 -14.742
G NW APARTMENT 6.329 -4.938 0.000 0.000 3.892 1.087 12.213 10.285 0.000 0.200 0.000 0.000 -10.408 0.000 -7.765 -10.893
OFFICE 3.028 -16.056 0.000 0.000 0.521 29.882 9.495 17.792 0.000 0.118 0.000 0.000 -10.415 0.000 -4.819 -29.546
G NE APARTMENT 6.243 -4.829 0.000 0.000 3.913 1.087 12.213 9.342 0.000 0.199 0.000 0.000 -10.112 0.000 -7.725 -10.330
G N1 APARTMENT 2.998 -4.488 0.000 0.000 3.915 1.087 12.213 3.551 0.000 0.152 0.000 0.000 -6.365 0.000 -5.639 -7.424
G N2 APARTMENT 3.001 -4.477 0.000 0.000 3.917 1.087 12.213 3.551 0.000 0.152 0.000 0.000 -6.360 0.000 -5.634 -7.448
G S1 APARTMENT 1.611 -7.094 0.000 0.000 3.845 1.087 12.213 12.190 0.000 0.151 0.000 0.000 -6.347 0.000 -6.242 -11.414
G S2 APARTMENT 1.495 -7.287 0.000 0.000 3.839 1.087 12.213 12.171 0.000 0.151 0.000 0.000 -6.366 0.000 -6.298 -11.004
F2 SW APARTMENT 3.803 -12.462 0.000 0.000 3.761 1.087 12.213 18.214 0.000 0.262 0.001 0.000 -11.171 0.000 -11.202 -4.505
F2 NW APARTMENT 5.501 -7.753 0.000 0.000 3.830 1.087 12.213 9.829 0.000 0.266 0.000 0.000 -11.062 0.000 -10.596 -3.315
F2 SE APARTMENT 3.206 -13.264 0.000 0.000 3.752 1.087 12.213 17.251 0.000 0.262 0.001 0.000 -11.060 0.000 -11.333 -2.113
F2 NE APARTMENT 5.381 -7.568 0.000 0.000 3.854 1.087 12.213 8.912 0.000 0.264 0.000 0.000 -10.730 0.000 -10.518 -2.893
F2 N1 APARTMENT 1.774 -7.013 0.000 0.000 3.850 1.087 12.213 3.301 0.000 0.197 0.000 0.000 -6.812 0.000 -7.613 -0.983
F2 N2 APARTMENT 1.779 -6.994 0.000 0.000 3.852 1.087 12.213 3.302 0.000 0.196 0.000 0.000 -6.805 0.000 -7.604 -1.026
F2 S1 APARTMENT 1.019 -11.633 0.000 0.000 3.745 1.087 12.213 11.813 0.000 0.195 0.002 0.000 -6.845 0.000 -8.370 -3.222
F2 S2 APARTMENT 0.998 -11.734 0.000 0.000 3.742 1.087 12.213 11.807 0.000 0.195 0.002 0.000 -6.853 0.000 -8.387 -3.068
F3 SW APARTMENT 3.931 -13.366 0.000 0.000 3.748 1.087 12.213 17.987 0.000 0.313 0.000 0.000 -11.398 0.000 -12.765 -1.750
F3 NW APARTMENT 5.629 -8.364 0.000 0.000 3.818 1.087 12.213 9.665 0.000 0.318 0.000 0.000 -11.273 0.000 -12.136 -0.957
F3 SE APARTMENT 3.757 -13.146 0.000 0.000 3.755 1.087 12.213 17.098 0.000 0.314 0.000 0.000 -11.174 0.000 -12.779 -1.123
F3 NE APARTMENT 5.519 -8.161 0.000 0.000 3.841 1.087 12.213 8.764 0.000 0.316 0.000 0.000 -10.935 0.000 -12.047 -0.595
F3 N1 APARTMENT 1.720 -7.764 0.000 0.000 3.830 1.087 12.213 3.219 0.000 0.236 1.098 0.000 -6.959 0.000 -8.679 -0.000
F3 N2 APARTMENT 1.724 -7.739 0.000 0.000 3.833 1.087 12.213 3.220 0.000 0.236 1.048 0.000 -6.952 0.000 -8.669 -0.000
F3 S1 APARTMENT 1.018 -12.901 0.000 0.000 3.722 1.087 12.213 11.665 0.000 0.235 0.001 0.000 -7.011 0.000 -9.457 -0.570
F3 S2 APARTMENT 1.015 -12.909 0.000 0.000 3.722 1.087 12.213 11.663 0.000 0.235 0.000 0.000 -7.011 0.000 -9.461 -0.553
F4 SW APARTMENT 4.246 -13.447 0.000 0.000 3.747 1.087 12.213 17.856 0.000 0.342 0.001 0.000 -11.501 0.000 -13.636 -0.905
F4 NW APARTMENT 6.000 -8.431 0.000 0.000 3.815 1.087 12.213 9.576 0.000 0.348 0.000 0.000 -11.377 0.000 -13.025 -0.205
F4 SE APARTMENT 4.160 -13.054 0.000 0.000 3.757 1.087 12.213 16.988 0.000 0.342 0.000 0.000 -11.253 0.000 -13.625 -0.614
F4 NE APARTMENT 5.887 -8.248 0.000 0.000 3.838 1.087 12.213 8.685 0.000 0.345 0.160 0.000 -11.037 0.000 -12.929 -0.000
F4 N1 APARTMENT 1.826 -7.932 0.000 0.000 3.824 1.087 12.213 3.177 0.000 0.256 1.794 0.000 -7.034 0.000 -9.210 -0.000
F4 N2 APARTMENT 1.831 -7.905 0.000 0.000 3.826 1.087 12.213 3.179 0.000 0.256 1.741 0.000 -7.026 0.000 -9.200 -0.000
F4 S1 APARTMENT 1.108 -13.182 0.000 0.000 3.717 1.087 12.213 11.581 0.000 0.254 0.269 0.000 -7.086 0.000 -9.962 -0.000
F4 S2 APARTMENT 1.110 -13.157 0.000 0.000 3.718 1.087 12.213 11.580 0.000 0.254 0.243 0.000 -7.084 0.000 -9.963 -0.000
M SW APARTMENT 4.550 -13.459 0.000 0.000 3.748 1.087 12.213 17.756 0.000 0.364 0.000 0.000 -11.580 0.000 -14.573 -0.106
M NW APARTMENT 6.314 -8.494 0.000 0.000 3.815 1.087 12.213 9.511 0.000 0.370 0.588 0.000 -11.459 0.000 -13.943 -0.001
M SE APARTMENT 4.481 -13.038 0.000 0.000 3.759 1.087 12.213 16.898 0.000 0.365 0.119 0.000 -11.326 0.000 -14.555 -0.000
M NE APARTMENT 6.195 -8.322 0.000 0.000 3.838 1.087 12.213 8.627 0.000 0.367 0.952 0.000 -11.118 0.000 -13.840 -0.000
M N1 APARTMENT 1.935 -8.077 0.000 0.000 3.822 1.087 12.213 3.149 0.000 0.272 2.517 0.000 -7.091 0.000 -9.825 -0.000
M N2 APARTMENT 1.938 -8.050 0.000 0.000 3.824 1.087 12.213 3.150 0.000 0.271 2.465 0.000 -7.083 0.000 -9.815 -0.000
M S1 APARTMENT 1.208 -13.310 0.000 0.000 3.717 1.087 12.213 11.518 0.000 0.270 1.031 0.000 -7.140 0.000 -10.593 -0.000
M S2 APARTMENT 1.211 -13.277 0.000 0.000 3.717 1.087 12.213 11.518 0.000 0.270 0.992 0.000 -7.137 0.000 -10.593 -0.000
F6 SW APARTMENT 5.175 -12.695 0.000 0.000 3.758 1.087 12.213 17.711 0.000 0.384 0.000 0.000 -11.574 0.000 -15.306 -0.752
F6 NW APARTMENT 7.102 -7.958 0.000 0.000 3.825 1.087 12.213 9.494 0.000 0.391 0.000 0.000 -11.456 0.000 -14.640 -0.056
F6 SE APARTMENT 5.115 -12.289 0.000 0.000 3.769 1.087 12.213 16.859 0.000 0.385 0.001 0.000 -11.318 0.000 -15.286 -0.534
F6 NE APARTMENT 6.988 -7.811 0.000 0.000 3.848 1.087 12.213 8.618 0.000 0.386 0.315 0.000 -11.114 0.000 -14.530 -0.000
F6 N1 APARTMENT 2.327 -7.525 0.000 0.000 3.832 1.087 12.213 3.149 0.000 0.286 1.968 0.000 -7.085 0.000 -10.251 -0.000
F6 N2 APARTMENT 2.328 -7.497 0.000 0.000 3.834 1.087 12.213 3.151 0.000 0.285 1.917 0.000 -7.078 0.000 -10.239 -0.000
F6 S1 APARTMENT 1.465 -12.542 0.000 0.000 3.728 1.087 12.213 11.490 0.000 0.284 0.470 0.000 -7.134 0.000 -11.060 -0.000
F6 S2 APARTMENT 1.468 -12.509 0.000 0.000 3.729 1.087 12.213 11.490 0.000 0.284 0.429 0.000 -7.131 0.000 -11.060 -0.000
F7 SW APARTMENT 5.699 -12.205 0.000 0.000 3.766 1.087 12.213 17.666 0.000 0.400 0.001 0.000 -11.580 0.000 -15.950 -1.095
F7 NW APARTMENT 7.718 -7.632 0.000 0.000 3.832 1.087 12.213 9.475 0.000 0.407 0.000 0.000 -11.465 0.000 -15.260 -0.374
F7 SE APARTMENT 5.643 -11.807 0.000 0.000 3.777 1.087 12.213 16.820 0.000 0.401 0.000 0.000 -11.323 0.000 -15.930 -0.878
F7 NE APARTMENT 7.601 -7.495 0.000 0.000 3.855 1.087 12.213 8.605 0.000 0.402 0.000 0.000 -11.123 0.000 -15.143 -0.001
F7 N1 APARTMENT 2.638 -7.188 0.000 0.000 3.840 1.087 12.213 3.147 0.000 0.297 1.683 0.000 -7.087 0.000 -10.630 -0.000
F7 N2 APARTMENT 2.643 -7.165 0.000 0.000 3.843 1.087 12.213 3.149 0.000 0.296 1.633 0.000 -7.080 0.000 -10.618 -0.000
F7 S1 APARTMENT 1.689 -12.040 0.000 0.000 3.737 1.087 12.213 11.464 0.000 0.295 0.161 0.000 -7.135 0.000 -11.469 -0.000
F7 S2 APARTMENT 1.692 -12.007 0.000 0.000 3.738 1.087 12.213 11.463 0.000 0.295 0.120 0.000 -7.132 0.000 -11.468 -0.000
F8 SW APARTMENT 6.222 -11.796 0.000 0.000 3.773 1.087 12.213 17.628 0.000 0.419 0.000 0.000 -11.585 0.000 -16.557 -1.403
F8 NW APARTMENT 8.312 -7.384 0.000 0.000 3.838 1.087 12.213 9.458 0.000 0.426 0.000 0.000 -11.474 0.000 -15.844 -0.633
F8 SE APARTMENT 6.171 -11.416 0.000 0.000 3.784 1.087 12.213 16.786 0.000 0.419 0.000 0.000 -11.327 0.000 -16.537 -1.179
F8 NE APARTMENT 8.200 -7.256 0.000 0.000 3.861 1.087 12.213 8.593 0.000 0.421 0.000 0.000 -11.133 0.000 -15.724 -0.262
F8 N1 APARTMENT 2.964 -6.922 0.000 0.000 3.847 1.087 12.213 3.145 0.000 0.311 1.443 0.000 -7.090 0.000 -10.998 -0.001
F8 N2 APARTMENT 2.968 -6.899 0.000 0.000 3.849 1.087 12.213 3.146 0.000 0.311 1.393 0.000 -7.083 0.000 -10.986 -0.000
F8 S1 APARTMENT 1.925 -11.603 0.000 0.000 3.746 1.087 12.213 11.441 0.000 0.309 0.000 0.000 -7.134 0.000 -11.862 -0.121
F8 S2 APARTMENT 1.930 -11.572 0.000 0.000 3.746 1.087 12.213 11.441 0.000 0.309 0.001 0.000 -7.130 0.000 -11.861 -0.162
F9 SW APARTMENT 7.174 -11.350 0.000 0.000 3.782 1.087 12.213 17.615 0.000 0.436 0.001 0.000 -11.556 0.000 -17.073 -2.328
F9 NW APARTMENT 9.395 -7.162 0.000 0.000 3.844 1.087 12.213 9.459 0.000 0.443 0.000 0.000 -11.460 0.000 -16.348 -1.471
F9 SE APARTMENT 7.105 -10.965 0.000 0.000 3.793 1.087 12.213 16.777 0.000 0.436 0.000 0.000 -11.300 0.000 -17.057 -2.087
F9 NE APARTMENT 9.259 -7.042 0.000 0.000 3.867 1.087 12.213 8.598 0.000 0.440 0.000 0.000 -11.121 0.000 -16.230 -1.071
F9 N1 APARTMENT 3.651 -6.577 0.000 0.000 3.854 1.087 12.213 3.151 0.000 0.325 0.685 0.000 -7.076 0.000 -11.311 -0.000
F9 N2 APARTMENT 3.658 -6.558 0.000 0.000 3.856 1.087 12.213 3.152 0.000 0.325 0.637 0.000 -7.069 0.000 -11.300 -0.001
F9 S1 APARTMENT 2.410 -11.002 0.000 0.000 3.757 1.087 12.213 11.436 0.000 0.322 0.000 0.000 -7.109 0.000 -12.183 -0.931
F9 S2 APARTMENT 2.415 -10.971 0.000 0.000 3.758 1.087 12.213 11.435 0.000 0.322 0.001 0.000 -7.106 0.000 -12.183 -0.969
T SW APARTMENT 11.746 -11.642 0.000 0.000 3.828 1.087 12.213 17.394 0.000 0.447 0.000 0.000 -11.027 0.000 -17.524 -6.519
T NW APARTMENT 13.654 -7.534 0.000 0.000 3.878 1.087 12.213 9.275 0.000 0.455 0.000 0.000 -11.002 0.000 -16.861 -5.163
T SE APARTMENT 11.496 -11.025 0.000 0.000 3.840 1.087 12.213 16.586 0.000 0.447 0.000 0.000 -10.807 0.000 -17.521 -6.314
T NE APARTMENT 13.270 -7.141 0.000 0.000 3.903 1.087 12.213 8.449 0.000 0.454 0.000 0.000 -10.702 0.000 -16.765 -4.767
T N1 APARTMENT 6.857 -6.240 0.000 0.000 3.887 1.087 12.213 3.093 0.000 0.336 0.000 0.000 -6.783 0.000 -11.662 -2.788
T N2 APARTMENT 6.875 -6.208 0.000 0.000 3.888 1.087 12.213 3.091 0.000 0.337 0.000 0.000 -6.775 0.000 -11.661 -2.847
T S1 APARTMENT 5.263 -10.067 0.000 0.000 3.805 1.087 12.213 11.325 0.000 0.329 0.000 0.000 -6.818 0.000 -12.475 -4.661
T S2 APARTMENT 5.277 -10.049 0.000 0.000 3.806 1.087 12.213 11.323 0.000 0.329 0.000 0.000 -6.814 0.000 -12.477 -4.694
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 4.099 0.000 0.942 32.115 0.000 -2.332 0.000 -51.263 -0.001
F2 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.915 0.000 0.014 0.000 0.000 -1.421 0.000 -1.249 -15.699
F3 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.872 0.000 0.016 0.000 0.000 -1.481 0.000 -1.527 -15.320
F4 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.850 0.000 0.017 0.000 0.000 -1.508 0.000 -1.726 -15.072
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 32.880 0.000 1.824 0.000 0.015 0.000 0.000 -1.546 0.000 -1.963 -31.210
F6 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.834 0.000 0.020 0.000 0.000 -1.519 0.000 -1.999 -14.776
F7 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.835 0.000 0.021 0.000 0.000 -1.510 0.000 -2.091 -14.695
F8 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.833 0.000 0.022 0.000 0.000 -1.508 0.000 -2.181 -14.606
F9 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 1.833 0.000 0.022 0.000 0.000 -1.503 0.000 -2.256 -14.536
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 8.151 1.786 0.000 0.011 0.000 0.000 -1.460 0.000 -2.419 -22.509
Total Facility 356.631 -765.500 0.000 0.000 301.323 296.560 982.450 848.392 0.000 25.992 60.001 0.000 -740.234 0.000 -1021.809 -343.797


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 10-SEP-15:30 0.00 -2929.03 0.00 0.00 48.87 45.40 470.89 4041.59 0.00 124.00 0.00 0.00 0.00 0.00 0.00 -1801.72
G NW APARTMENT 24-JUN-18:00 0.00 -2305.68 0.00 0.00 137.68 87.56 588.62 3045.72 0.00 241.53 0.00 0.00 0.00 0.00 0.00 -1795.42
OFFICE 31-AUG-13:30 0.00 -3791.47 0.00 0.00 65.20 2345.88 588.62 3343.04 0.00 34.95 0.00 0.00 0.00 0.00 0.00 -2586.21
G NE APARTMENT 04-JUN-09:30 0.00 -1616.72 0.00 0.00 40.75 12.97 406.15 2375.07 0.00 313.58 0.00 0.00 0.00 0.00 0.00 -1531.80
G N1 APARTMENT 14-JUL-19:00 0.00 -1018.31 0.00 0.00 139.88 103.77 547.42 548.75 0.00 156.89 0.00 0.00 0.00 0.00 0.00 -478.40
G N2 APARTMENT 14-JUL-19:00 0.00 -993.48 0.00 0.00 139.73 103.77 547.42 549.03 0.00 154.65 0.00 0.00 0.00 0.00 0.00 -501.12
G S1 APARTMENT 31-AUG-12:45 0.00 -2045.33 0.00 0.00 40.75 12.97 388.49 3254.24 0.00 172.80 0.00 0.00 0.00 0.00 0.00 -1823.93
G S2 APARTMENT 31-AUG-12:45 0.00 -2104.89 0.00 0.00 40.75 12.97 388.49 3253.08 0.00 172.80 0.00 0.00 0.00 0.00 0.00 -1763.20
F2 SW APARTMENT 09-SEP-15:30 0.00 -3705.48 0.00 0.00 48.87 45.40 470.89 3840.11 0.00 351.45 0.00 0.00 0.00 0.00 0.00 -1051.25
F2 NW APARTMENT 24-JUN-18:00 0.00 -2953.41 0.00 0.00 137.72 87.56 588.62 3000.72 0.00 345.93 0.00 0.00 0.00 0.00 0.00 -1207.14
F2 SE APARTMENT 09-SEP-13:30 0.00 -3367.96 0.00 0.00 40.75 12.97 382.60 3454.93 0.00 313.08 0.00 0.00 0.00 0.00 0.00 -836.38
F2 NE APARTMENT 04-JUN-09:30 0.00 -2200.60 0.00 0.00 40.75 12.97 406.15 2327.12 0.00 397.77 0.00 0.00 0.00 0.00 0.00 -984.16
F2 N1 APARTMENT 14-JUL-19:00 0.00 -1394.67 0.00 0.00 140.13 103.77 547.42 533.76 0.00 194.35 0.00 0.00 0.00 0.00 0.00 -124.75
F2 N2 APARTMENT 14-JUL-19:00 0.00 -1372.05 0.00 0.00 140.01 103.77 547.42 533.89 0.00 192.39 0.00 0.00 0.00 0.00 0.00 -145.43
F2 S1 APARTMENT 31-AUG-12:45 0.00 -2619.28 0.00 0.00 40.75 12.97 388.49 3230.50 0.00 189.24 0.00 0.00 0.00 0.00 0.00 -1242.66
F2 S2 APARTMENT 31-AUG-12:45 0.00 -2643.66 0.00 0.00 40.75 12.97 388.49 3230.12 0.00 189.24 0.00 0.00 0.00 0.00 0.00 -1217.91
F3 SW APARTMENT 09-SEP-15:15 0.00 -3757.95 0.00 0.00 48.90 45.40 470.89 3959.68 0.00 407.83 0.00 0.00 0.00 0.00 0.00 -1174.75
F3 NW APARTMENT 23-JUN-18:00 0.00 -3008.71 0.00 0.00 140.39 87.56 588.62 2872.94 0.00 385.50 0.00 0.00 0.00 0.00 0.00 -1066.29
F3 SE APARTMENT 09-SEP-13:30 0.00 -3395.70 0.00 0.00 40.75 12.97 382.60 3440.98 0.00 369.74 0.00 0.00 0.00 0.00 0.00 -851.35
F3 NE APARTMENT 04-JUN-09:30 0.00 -2265.82 0.00 0.00 40.68 12.97 406.15 2305.76 0.00 440.73 0.00 0.00 0.00 0.00 0.00 -940.47
F3 N1 APARTMENT 22-JUN-16:15 0.00 -1458.93 0.00 0.00 84.76 64.86 588.62 473.68 0.00 443.85 0.00 0.00 0.00 0.00 0.00 -196.83
F3 N2 APARTMENT 22-JUN-16:15 0.00 -1448.70 0.00 0.00 84.76 64.86 588.62 473.90 0.00 443.85 0.00 0.00 0.00 0.00 0.00 -207.28
F3 S1 APARTMENT 30-AUG-14:00 0.00 -2708.94 0.00 0.00 40.75 12.97 382.60 2750.76 0.00 287.33 0.00 0.00 0.00 0.00 0.00 -765.47
F3 S2 APARTMENT 31-AUG-13:00 0.00 -2720.85 0.00 0.00 40.75 12.97 388.49 3173.30 0.00 254.09 0.00 0.00 0.00 0.00 0.00 -1148.75
F4 SW APARTMENT 09-SEP-15:30 0.00 -3792.47 0.00 0.00 48.80 45.40 470.89 3791.51 0.00 461.31 0.00 0.00 0.00 0.00 0.00 -1025.45
F4 NW APARTMENT 23-JUN-17:45 0.00 -3047.02 0.00 0.00 140.49 87.56 588.62 2941.22 0.00 440.60 0.00 0.00 0.00 0.00 0.00 -1151.47
F4 SE APARTMENT 09-SEP-13:30 0.00 -3432.31 0.00 0.00 40.75 12.97 382.60 3430.77 0.00 412.23 0.00 0.00 0.00 0.00 0.00 -847.01
F4 NE APARTMENT 04-JUN-09:30 0.00 -2299.67 0.00 0.00 40.67 12.97 406.15 2292.15 0.00 477.92 0.00 0.00 0.00 0.00 0.00 -930.18
F4 N1 APARTMENT 22-JUN-16:15 0.00 -1511.84 0.00 0.00 84.76 64.86 588.62 471.57 0.00 484.84 0.00 0.00 0.00 0.00 0.00 -182.79
F4 N2 APARTMENT 22-JUN-16:15 0.00 -1488.30 0.00 0.00 84.76 64.86 588.62 471.79 0.00 482.08 0.00 0.00 0.00 0.00 0.00 -203.79
F4 S1 APARTMENT 31-AUG-13:00 0.00 -2729.86 0.00 0.00 40.75 12.97 388.49 3165.26 0.00 263.18 0.00 0.00 0.00 0.00 0.00 -1140.78
F4 S2 APARTMENT 31-AUG-13:00 0.00 -2741.57 0.00 0.00 40.75 12.97 388.49 3165.02 0.00 262.95 0.00 0.00 0.00 0.00 0.00 -1128.61
M SW APARTMENT 09-SEP-15:30 0.00 -3841.99 0.00 0.00 48.79 45.40 470.89 3775.74 0.00 499.86 0.00 0.00 0.00 0.00 0.00 -998.70
M NW APARTMENT 23-JUN-17:45 0.00 -3105.78 0.00 0.00 140.53 87.56 588.62 2932.76 0.00 477.70 0.00 0.00 0.00 0.00 0.00 -1121.39
M SE APARTMENT 09-SEP-13:30 0.00 -3484.67 0.00 0.00 40.75 12.97 382.60 3422.09 0.00 446.86 0.00 0.00 0.00 0.00 0.00 -820.60
M NE APARTMENT 04-JUN-09:30 0.00 -2341.52 0.00 0.00 40.66 12.97 406.15 2281.03 0.00 506.91 0.00 0.00 0.00 0.00 0.00 -906.20
M N1 APARTMENT 22-JUN-16:15 0.00 -1552.59 0.00 0.00 84.76 64.86 588.62 469.79 0.00 515.40 0.00 0.00 0.00 0.00 0.00 -170.83
M N2 APARTMENT 22-JUN-15:30 0.00 -1540.25 0.00 0.00 48.90 45.40 470.89 549.27 0.00 602.92 0.00 0.00 0.00 0.00 0.00 -177.14
M S1 APARTMENT 31-AUG-13:00 0.00 -2768.73 0.00 0.00 40.75 12.97 388.49 3158.26 0.00 270.67 0.00 0.00 0.00 0.00 0.00 -1102.41
M S2 APARTMENT 31-AUG-13:00 0.00 -2780.12 0.00 0.00 40.75 12.97 388.49 3158.02 0.00 270.43 0.00 0.00 0.00 0.00 0.00 -1090.54
F6 SW APARTMENT 09-SEP-15:15 0.00 -3822.70 0.00 0.00 48.88 45.40 470.89 3919.87 0.00 524.54 0.00 0.00 0.00 0.00 0.00 -1186.89
F6 NW APARTMENT 23-JUN-17:45 0.00 -3088.09 0.00 0.00 140.49 87.56 588.62 2927.25 0.00 508.60 0.00 0.00 0.00 0.00 0.00 -1164.43
F6 SE APARTMENT 09-SEP-13:30 0.00 -3472.61 0.00 0.00 40.75 12.97 382.60 3416.45 0.00 476.38 0.00 0.00 0.00 0.00 0.00 -856.53
F6 NE APARTMENT 04-JUN-09:30 0.00 -2315.32 0.00 0.00 40.65 12.97 406.15 2273.63 0.00 529.62 0.00 0.00 0.00 0.00 0.00 -947.70
F6 N1 APARTMENT 22-JUN-15:30 0.00 -1528.13 0.00 0.00 48.90 45.40 470.89 549.33 0.00 634.54 0.00 0.00 0.00 0.00 0.00 -220.93
F6 N2 APARTMENT 22-JUN-15:30 0.00 -1521.02 0.00 0.00 48.90 45.40 470.89 549.47 0.00 634.54 0.00 0.00 0.00 0.00 0.00 -228.19
F6 S1 APARTMENT 31-AUG-13:00 0.00 -2741.60 0.00 0.00 40.75 12.97 388.49 3153.30 0.00 276.74 0.00 0.00 0.00 0.00 0.00 -1130.65
F6 S2 APARTMENT 31-AUG-13:00 0.00 -2752.94 0.00 0.00 40.75 12.97 388.49 3153.06 0.00 276.48 0.00 0.00 0.00 0.00 0.00 -1118.82
F7 SW APARTMENT 09-SEP-15:15 0.00 -3824.75 0.00 0.00 48.86 45.40 470.89 3911.27 0.00 552.82 0.00 0.00 0.00 0.00 0.00 -1204.50
F7 NW APARTMENT 23-JUN-17:45 0.00 -3092.02 0.00 0.00 140.45 87.56 588.62 2922.08 0.00 535.74 0.00 0.00 0.00 0.00 0.00 -1182.42
F7 SE APARTMENT 09-SEP-13:30 0.00 -3478.02 0.00 0.00 40.75 12.97 382.60 3411.09 0.00 502.23 0.00 0.00 0.00 0.00 0.00 -871.63
F7 NE APARTMENT 04-JUN-09:30 0.00 -2311.34 0.00 0.00 40.65 12.97 406.15 2266.81 0.00 549.32 0.00 0.00 0.00 0.00 0.00 -964.55
F7 N1 APARTMENT 26-AUG-18:15 0.00 -1530.72 0.00 0.00 141.81 103.77 547.42 200.11 0.00 478.11 59.50 0.00 0.00 0.00 0.00 0.00
F7 N2 APARTMENT 26-AUG-18:15 0.00 -1519.78 0.00 0.00 141.81 103.77 547.42 200.36 0.00 478.12 48.31 0.00 0.00 0.00 0.00 0.00
F7 S1 APARTMENT 31-AUG-13:00 0.00 -2736.38 0.00 0.00 40.75 12.97 388.49 3148.67 0.00 282.08 0.00 0.00 0.00 0.00 0.00 -1136.58
F7 S2 APARTMENT 31-AUG-13:00 0.00 -2747.70 0.00 0.00 40.75 12.97 388.49 3148.42 0.00 281.80 0.00 0.00 0.00 0.00 0.00 -1124.73
F8 SW APARTMENT 09-SEP-15:15 0.00 -3835.90 0.00 0.00 48.87 45.40 470.89 3903.83 0.00 578.51 0.00 0.00 0.00 0.00 0.00 -1211.61
F8 NW APARTMENT 23-JUN-18:00 0.00 -3100.44 0.00 0.00 140.26 87.56 588.62 2824.31 0.00 545.33 0.00 0.00 0.00 0.00 0.00 -1085.63
F8 SE APARTMENT 09-SEP-13:30 0.00 -3485.73 0.00 0.00 40.75 12.97 382.60 3406.28 0.00 525.32 0.00 0.00 0.00 0.00 0.00 -882.20
F8 NE APARTMENT 04-JUN-09:45 0.00 -2339.52 0.00 0.00 40.40 12.97 406.15 2147.32 0.00 685.95 0.00 0.00 0.00 0.00 0.00 -953.27
F8 N1 APARTMENT 04-JUN-09:45 0.00 -1560.58 0.00 0.00 40.75 12.97 406.15 505.17 0.00 714.62 0.00 0.00 0.00 0.00 0.00 -119.08
F8 N2 APARTMENT 04-JUN-09:45 0.00 -1548.34 0.00 0.00 40.75 12.97 406.15 504.66 0.00 707.82 0.00 0.00 0.00 0.00 0.00 -124.01
F8 S1 APARTMENT 31-AUG-13:00 0.00 -2741.29 0.00 0.00 40.75 12.97 388.49 3144.46 0.00 287.13 0.00 0.00 0.00 0.00 0.00 -1132.51
F8 S2 APARTMENT 31-AUG-13:00 0.00 -2752.64 0.00 0.00 40.75 12.97 388.49 3144.21 0.00 286.83 0.00 0.00 0.00 0.00 0.00 -1120.62
F9 SW APARTMENT 09-SEP-15:30 0.00 -3916.83 0.00 0.00 48.84 45.40 470.89 3737.62 0.00 613.16 0.00 0.00 0.00 0.00 0.00 -999.09
F9 NW APARTMENT 23-JUN-18:00 0.00 -3191.59 0.00 0.00 140.54 87.56 588.62 2817.25 0.00 569.16 0.00 0.00 0.00 0.00 0.00 -1011.53
F9 SE APARTMENT 09-SEP-13:45 0.00 -3512.95 0.00 0.00 40.75 12.97 382.60 3274.85 0.00 556.58 0.00 0.00 0.00 0.00 0.00 -754.81
F9 NE APARTMENT 04-JUN-09:45 0.00 -2451.10 0.00 0.00 40.65 12.97 406.15 2144.84 0.00 747.88 0.00 0.00 0.00 0.00 0.00 -901.39
F9 N1 APARTMENT 24-JUN-21:00 0.00 -1599.31 0.00 0.00 161.10 71.34 500.33 0.00 0.00 240.22 665.16 0.00 -38.84 0.00 0.00 0.00
F9 N2 APARTMENT 04-JUN-09:45 0.00 -1597.55 0.00 0.00 40.75 12.97 406.15 504.77 0.00 741.19 0.00 0.00 0.00 0.00 0.00 -108.28
F9 S1 APARTMENT 31-AUG-13:15 0.00 -2800.01 0.00 0.00 40.75 12.97 382.60 3052.71 0.00 337.37 0.00 0.00 0.00 0.00 0.00 -1026.40
F9 S2 APARTMENT 31-AUG-13:15 0.00 -2812.54 0.00 0.00 40.75 12.97 382.60 3052.44 0.00 337.09 0.00 0.00 0.00 0.00 0.00 -1013.31
T SW APARTMENT 17-JUL-16:15 0.00 -4665.95 0.00 0.00 84.57 64.86 588.62 3212.03 0.00 652.51 63.36 0.00 0.00 0.00 0.00 0.00
T NW APARTMENT 15-JUL-17:20 0.00 -3900.13 0.00 0.00 136.97 87.56 588.62 2937.02 0.00 576.25 0.00 0.00 0.00 0.00 0.00 -426.28
T SE APARTMENT 09-SEP-13:15 0.00 -4179.44 0.00 0.00 40.75 12.97 382.60 3441.35 0.00 554.67 0.00 0.00 0.00 0.00 0.00 -252.91
T NE APARTMENT 04-JUN-09:45 0.00 -3061.16 0.00 0.00 40.75 12.97 406.15 2109.57 0.00 817.14 0.00 0.00 0.00 0.00 0.00 -325.42
T N1 APARTMENT 24-JUN-19:15 0.00 -2258.68 0.00 0.00 139.48 103.77 523.87 861.81 0.00 200.20 429.55 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 24-JUN-19:15 0.00 -2251.70 0.00 0.00 140.19 103.77 523.87 864.11 0.00 202.36 417.40 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 10-SEP-13:15 0.00 -3621.65 0.00 0.00 40.74 12.97 382.60 3146.64 0.00 128.60 0.00 0.00 0.00 0.00 0.00 -89.90
T S2 APARTMENT 10-SEP-13:15 0.00 -3634.08 0.00 0.00 40.73 12.97 382.60 3146.33 0.00 128.55 0.00 0.00 0.00 0.00 0.00 -77.12
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 09-SEP-15:15 0.00 -193305.33 0.00 0.00 3862.72 9790.07 37759.52 151166.26 0.00 32891.19 0.00 0.00 0.00 0.00 0.00 -42164.44


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 15-FEB-02:00 1911.89 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -891.99 0.00 -1225.66 -231.72
G NW APARTMENT 15-FEB-02:00 1936.99 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -875.46 0.00 -1225.66 -273.36
OFFICE 15-FEB-02:00 1699.49 0.00 0.00 0.00 0.00 469.18 194.24 0.00 0.00 0.00 0.00 0.00 -900.09 0.00 -1225.66 -237.16
G NE APARTMENT 15-FEB-02:00 1940.23 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -875.33 0.00 -1225.66 -276.72
G N1 APARTMENT 23-MAR-14:55 1386.83 0.00 0.00 0.00 46.91 22.70 400.26 379.71 0.00 0.00 0.00 0.00 0.00 0.00 -1515.62 -720.78
G N2 APARTMENT 23-MAR-14:55 1369.18 0.00 0.00 0.00 46.96 22.70 400.26 380.33 0.00 0.00 0.00 0.00 0.00 0.00 -1515.54 -703.89
G S1 APARTMENT 09-NOV-10:55 1429.21 0.00 0.00 0.00 45.67 12.97 406.15 682.10 0.00 0.00 0.00 0.00 0.00 0.00 -1550.36 -1025.74
G S2 APARTMENT 26-OCT-13:00 1444.76 0.00 0.00 0.00 44.23 12.97 388.49 155.75 0.00 0.00 0.00 0.00 0.00 0.00 -1548.08 -498.13
F2 SW APARTMENT 15-FEB-02:00 2288.59 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -933.96 0.00 -1763.03 -29.09
F2 NW APARTMENT 15-FEB-02:00 2379.38 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -910.67 0.00 -1763.03 -143.17
F2 SE APARTMENT 15-FEB-02:00 2198.95 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 64.80 0.00 -938.22 0.00 -1763.03 0.00
F2 NE APARTMENT 15-FEB-02:00 2384.56 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -910.47 0.00 -1763.03 -148.56
F2 N1 APARTMENT 23-MAR-14:55 1696.71 0.00 0.00 0.00 44.98 22.70 400.26 340.49 0.00 0.00 0.00 0.00 0.00 0.00 -1954.24 -550.90
F2 N2 APARTMENT 23-MAR-14:55 1788.70 0.00 0.00 0.00 45.09 22.70 400.26 341.72 0.00 0.00 0.00 0.00 0.00 0.00 -1951.58 -646.89
F2 S1 APARTMENT 26-OCT-08:00 2132.79 0.00 0.00 0.00 65.59 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -130.60 0.00 -2109.62 -366.10
F2 S2 APARTMENT 26-OCT-08:00 2114.63 0.00 0.00 0.00 65.40 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -131.89 0.00 -2111.12 -344.96
F3 SW APARTMENT 15-FEB-02:00 2531.63 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 70.74 0.00 -951.00 0.00 -2088.86 0.00
F3 NW APARTMENT 15-FEB-02:00 2632.53 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -924.97 0.00 -2088.86 -56.19
F3 SE APARTMENT 15-FEB-02:00 2521.06 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 81.85 0.00 -951.54 0.00 -2088.86 0.00
F3 NE APARTMENT 15-FEB-02:00 2637.86 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -924.74 0.00 -2088.86 -61.74
F3 N1 APARTMENT 26-FEB-11:55 1760.27 0.00 0.00 0.00 46.19 12.97 412.03 198.73 0.00 0.00 0.00 0.00 0.00 0.00 -1617.13 -813.06
F3 N2 APARTMENT 26-FEB-11:55 1756.88 0.00 0.00 0.00 46.17 12.97 412.03 198.41 0.00 0.00 0.00 0.00 0.00 0.00 -1617.10 -809.36
F3 S1 APARTMENT 26-OCT-08:00 2325.01 0.00 0.00 0.00 64.69 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -145.13 0.00 -2424.26 -228.25
F3 S2 APARTMENT 26-OCT-08:00 2323.29 0.00 0.00 0.00 64.65 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -145.32 0.00 -2424.37 -226.20
F4 SW APARTMENT 15-FEB-02:00 2764.11 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 95.38 0.00 -960.46 0.00 -2336.52 0.00
F4 NW APARTMENT 15-FEB-02:00 2865.54 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -933.13 0.00 -2336.52 -33.38
F4 SE APARTMENT 15-FEB-02:00 2767.96 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 91.35 0.00 -960.28 0.00 -2336.52 0.00
F4 NE APARTMENT 15-FEB-02:00 2870.89 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -932.90 0.00 -2336.52 -38.95
F4 N1 APARTMENT 25-FEB-13:25 1787.66 0.00 0.00 0.00 45.99 12.97 388.49 302.98 0.00 0.00 0.00 0.00 0.00 0.00 -1574.08 -964.02
F4 N2 APARTMENT 25-FEB-13:25 1769.42 0.00 0.00 0.00 46.04 12.97 388.49 303.63 0.00 0.00 0.00 0.00 0.00 0.00 -1573.94 -946.62
F4 S1 APARTMENT 15-FEB-02:00 1434.47 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 127.51 0.00 -590.14 0.00 -1409.33 0.00
F4 S2 APARTMENT 15-FEB-02:00 1434.44 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 127.54 0.00 -590.14 0.00 -1409.33 0.00
M SW APARTMENT 15-FEB-02:00 2953.08 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 118.40 0.00 -967.84 0.00 -2541.12 0.00
M NW APARTMENT 15-FEB-02:00 3050.50 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -939.74 0.00 -2541.12 -7.12
M SE APARTMENT 15-FEB-02:00 2959.17 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 112.01 0.00 -967.55 0.00 -2541.12 0.00
M NE APARTMENT 15-FEB-02:00 3055.85 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -939.51 0.00 -2541.13 -12.70
M N1 APARTMENT 27-FEB-11:25 1861.22 0.00 0.00 0.00 45.91 12.97 412.03 189.64 0.00 0.00 0.00 0.00 0.00 0.00 -1646.79 -874.99
M N2 APARTMENT 25-FEB-13:25 1836.90 0.00 0.00 0.00 46.00 12.97 388.49 299.24 0.00 0.00 0.00 0.00 0.00 0.00 -1668.84 -914.76
M S1 APARTMENT 15-FEB-02:00 1545.41 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 144.68 0.00 -594.85 0.00 -1532.74 0.00
M S2 APARTMENT 15-FEB-02:00 1545.65 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 144.44 0.00 -594.83 0.00 -1532.74 0.00
F6 SW APARTMENT 15-FEB-02:00 3166.79 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 84.89 0.00 -971.33 0.00 -2717.84 0.00
F6 NW APARTMENT 15-FEB-02:00 3261.02 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -942.99 0.00 -2717.84 -37.69
F6 SE APARTMENT 15-FEB-02:00 3173.21 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 78.15 0.00 -971.02 0.00 -2717.84 0.00
F6 NE APARTMENT 15-FEB-02:00 3266.45 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -942.75 0.00 -2717.84 -43.34
F6 N1 APARTMENT 25-FEB-13:25 1831.43 0.00 0.00 0.00 46.19 12.97 388.49 298.11 0.00 0.00 0.00 0.00 0.00 0.00 -1753.23 -823.97
F6 N2 APARTMENT 25-OCT-11:10 1870.57 0.00 0.00 0.00 45.60 12.97 406.15 317.48 0.00 0.00 0.00 0.00 0.00 0.00 -1847.90 -804.88
F6 S1 APARTMENT 15-FEB-02:00 1676.55 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 122.10 0.00 -596.81 0.00 -1639.33 0.00
F6 S2 APARTMENT 15-FEB-02:00 1676.84 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 121.80 0.00 -596.80 0.00 -1639.33 0.00
F7 SW APARTMENT 15-FEB-02:00 3345.58 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 66.44 0.00 -974.75 0.00 -2874.76 0.00
F7 NW APARTMENT 15-FEB-02:00 3435.10 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -946.25 0.00 -2874.76 -51.58
F7 SE APARTMENT 15-FEB-02:00 3351.86 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 59.87 0.00 -974.46 0.00 -2874.76 0.00
F7 NE APARTMENT 15-FEB-02:00 3440.59 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -946.01 0.00 -2874.77 -57.30
F7 N1 APARTMENT 25-OCT-11:10 2107.47 0.00 0.00 0.00 45.73 12.97 406.15 316.57 0.00 0.00 0.00 0.00 0.00 0.00 -1926.16 -962.73
F7 N2 APARTMENT 25-OCT-11:10 2127.07 0.00 0.00 0.00 45.79 12.97 406.15 317.25 0.00 0.00 0.00 0.00 0.00 0.00 -1925.21 -984.02
F7 S1 APARTMENT 15-FEB-02:00 1788.79 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 106.47 0.00 -598.76 0.00 -1733.98 0.00
F7 S2 APARTMENT 15-FEB-02:00 1789.11 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 106.13 0.00 -598.75 0.00 -1733.98 0.00
F8 SW APARTMENT 15-FEB-02:00 3513.99 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 42.78 0.00 -977.46 0.00 -3016.80 0.00
F8 NW APARTMENT 15-FEB-02:00 3597.47 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -948.92 0.00 -3016.80 -69.23
F8 SE APARTMENT 15-FEB-02:00 3520.08 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 36.41 0.00 -977.17 0.00 -3016.80 0.00
F8 NE APARTMENT 15-FEB-02:00 3603.03 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -948.68 0.00 -3016.81 -75.03
F8 N1 APARTMENT 25-OCT-11:10 2161.95 0.00 0.00 0.00 45.89 12.97 406.15 316.49 0.00 0.00 0.00 0.00 0.00 0.00 -2001.66 -941.79
F8 N2 APARTMENT 25-OCT-11:10 2144.59 0.00 0.00 0.00 45.95 12.97 406.15 317.07 0.00 0.00 0.00 0.00 0.00 0.00 -2001.54 -925.19
F8 S1 APARTMENT 15-FEB-02:00 1898.99 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 83.33 0.00 -600.15 0.00 -1819.66 0.00
F8 S2 APARTMENT 15-FEB-02:00 1899.30 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 83.01 0.00 -600.14 0.00 -1819.66 0.00
F9 SW APARTMENT 15-FEB-02:00 3748.25 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -976.60 0.00 -3147.18 -61.96
F9 NW APARTMENT 15-FEB-02:00 3815.43 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -948.63 0.00 -3147.18 -157.11
F9 SE APARTMENT 15-FEB-02:00 3754.17 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -976.34 0.00 -3147.18 -68.14
F9 NE APARTMENT 15-FEB-02:00 3821.04 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -948.40 0.00 -3147.19 -162.94
F9 N1 APARTMENT 15-FEB-02:00 2167.53 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -572.09 0.00 -1898.31 -134.63
F9 N2 APARTMENT 15-FEB-02:00 2167.93 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -572.08 0.00 -1898.31 -135.03
F9 S1 APARTMENT 12-DEC-14:10 2083.51 0.00 0.00 0.00 45.06 12.97 382.60 1483.71 0.00 0.00 0.00 0.00 0.00 0.00 -2242.52 -1765.34
F9 S2 APARTMENT 12-DEC-14:10 2098.33 0.00 0.00 0.00 45.06 12.97 382.60 1483.76 0.00 0.00 0.00 0.00 0.00 0.00 -2242.44 -1780.29
T SW APARTMENT 15-FEB-02:00 4291.24 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -953.91 0.00 -3267.87 -506.94
T NW APARTMENT 15-FEB-02:00 4309.97 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -927.38 0.00 -3267.87 -552.21
T SE APARTMENT 15-FEB-02:00 4293.98 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -953.77 0.00 -3267.87 -509.82
T NE APARTMENT 15-FEB-02:00 4312.59 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -927.26 0.00 -3267.88 -554.95
T N1 APARTMENT 15-FEB-02:00 2627.63 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -557.26 0.00 -1971.17 -536.68
T N2 APARTMENT 15-FEB-02:00 2627.85 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -557.25 0.00 -1971.17 -536.92
T S1 APARTMENT 15-FEB-02:00 2596.38 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -585.41 0.00 -1971.17 -477.29
T S2 APARTMENT 15-FEB-02:00 2596.57 0.00 0.00 0.00 189.67 6.49 241.33 0.00 0.00 0.00 0.00 0.00 -585.40 0.00 -1971.17 -477.48
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 15-FEB-02:00 191659.60 0.00 0.00 0.00 14983.97 6715.87 19318.62 0.00 0.00 0.00 0.00 0.00 -61989.75 0.00 -164296.27 -6392.05



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:13

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:13

Sec1.1A-General Information

Data
Weather File Salem Mcnary Field OR USA TMY3 WMO#=726940
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 7836.48
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.50
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
F2 SW APARTMENT 88.25 88.25 0.00 168.00
F2 NW APARTMENT 88.25 88.25 0.00 168.00
F2 SE APARTMENT 88.25 88.25 0.00 168.00
F2 NE APARTMENT 88.25 88.25 0.00 168.00
F2 N1 APARTMENT 88.25 88.25 0.00 168.00
F2 N2 APARTMENT 88.25 88.25 0.00 168.00
F2 S1 APARTMENT 88.25 88.25 0.00 168.00
F2 S2 APARTMENT 88.25 88.25 0.00 168.00
F3 SW APARTMENT 88.25 88.25 0.00 168.00
F3 NW APARTMENT 88.25 88.25 0.00 168.00
F3 SE APARTMENT 88.25 88.25 0.00 168.00
F3 NE APARTMENT 88.25 88.25 0.00 168.00
F3 N1 APARTMENT 88.25 88.25 0.00 168.00
F3 N2 APARTMENT 88.25 88.25 0.00 168.00
F3 S1 APARTMENT 88.25 88.25 0.00 168.00
F3 S2 APARTMENT 88.25 88.25 0.00 168.00
F4 SW APARTMENT 88.25 88.25 0.00 168.00
F4 NW APARTMENT 88.25 88.25 0.00 168.00
F4 SE APARTMENT 88.25 88.25 0.00 168.00
F4 NE APARTMENT 88.25 88.25 0.00 168.00
F4 N1 APARTMENT 88.25 88.25 0.00 168.00
F4 N2 APARTMENT 88.25 88.25 0.00 168.00
F4 S1 APARTMENT 88.25 88.25 0.00 168.00
F4 S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
F6 SW APARTMENT 88.25 88.25 0.00 168.00
F6 NW APARTMENT 88.25 88.25 0.00 168.00
F6 SE APARTMENT 88.25 88.25 0.00 168.00
F6 NE APARTMENT 88.25 88.25 0.00 168.00
F6 N1 APARTMENT 88.25 88.25 0.00 168.00
F6 N2 APARTMENT 88.25 88.25 0.00 168.00
F6 S1 APARTMENT 88.25 88.25 0.00 168.00
F6 S2 APARTMENT 88.25 88.25 0.00 168.00
F7 SW APARTMENT 88.25 88.25 0.00 168.00
F7 NW APARTMENT 88.25 88.25 0.00 168.00
F7 SE APARTMENT 88.25 88.25 0.00 168.00
F7 NE APARTMENT 88.25 88.25 0.00 168.00
F7 N1 APARTMENT 88.25 88.25 0.00 168.00
F7 N2 APARTMENT 88.25 88.25 0.00 168.00
F7 S1 APARTMENT 88.25 88.25 0.00 168.00
F7 S2 APARTMENT 88.25 88.25 0.00 168.00
F8 SW APARTMENT 88.25 88.25 0.00 168.00
F8 NW APARTMENT 88.25 88.25 0.00 168.00
F8 SE APARTMENT 88.25 88.25 0.00 168.00
F8 NE APARTMENT 88.25 88.25 0.00 168.00
F8 N1 APARTMENT 88.25 88.25 0.00 168.00
F8 N2 APARTMENT 88.25 88.25 0.00 168.00
F8 S1 APARTMENT 88.25 88.25 0.00 168.00
F8 S2 APARTMENT 88.25 88.25 0.00 168.00
F9 SW APARTMENT 88.25 88.25 0.00 168.00
F9 NW APARTMENT 88.25 88.25 0.00 168.00
F9 SE APARTMENT 88.25 88.25 0.00 168.00
F9 NE APARTMENT 88.25 88.25 0.00 168.00
F9 N1 APARTMENT 88.25 88.25 0.00 168.00
F9 N2 APARTMENT 88.25 88.25 0.00 168.00
F9 S1 APARTMENT 88.25 88.25 0.00 168.00
F9 S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
G CORRIDOR 77.66 0.00 77.66 0.00
F2 CORRIDOR 77.66 0.00 77.66 0.00
F3 CORRIDOR 77.66 0.00 77.66 0.00
F4 CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
F6 CORRIDOR 77.66 0.00 77.66 0.00
F7 CORRIDOR 77.66 0.00 77.66 0.00
F8 CORRIDOR 77.66 0.00 77.66 0.00
F9 CORRIDOR 77.66 0.00 77.66 0.00
T CORRIDOR 77.66 0.00 77.66 0.00
Totals 7836.48 7059.89 776.58  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 155.00
Number of hours cooling loads not met 86.75
Number of hours not met 241.75


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 296.56 13120.46 0.00 0.00 0.00 0.00
Exterior Lighting 162.79 0.00 0.00 0.00 0.00 0.00
Space Heating 143.57 0.00 483.12 179384.52 0.00 0.00
Space Cooling 235.55 67773.43 0.00 0.00 0.00 0.00
Pumps 61.04 1959.84 0.00 0.00 0.00 0.00
Heat Rejection 9.60 2573.63 0.00 0.00 0.00 0.00
Fans-Interior 662.42 21005.32 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 0.00 0.00 1149.45 78981.47 0.00 0.00
Receptacle Equipment 1137.32 57042.02 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 2745.02   1632.57   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 1137.32 2745.02
Natural Gas 0.00 1632.57
Additional 0.00 0.00
Total 1137.32 4377.59


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 37.84
Space Heating 18.32
Space Cooling 30.06
Fans-Interior 84.53
Service Water Heating 0.00
Receptacle Equipment 145.13
Miscellaneous 34.40
Subtotal 350.29


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 61.65
Service Water Heating 146.68
Miscellaneous -0.00
Subtotal 208.33


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 6.77
Space Heating 14.32
Space Cooling 5.38
Fans-Interior 15.13
Service Water Heating 26.26
Receptacle Equipment 25.98
Miscellaneous 6.16



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:13

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.252777
G NW APARTMENT DIRECT AIR 0.194152
OFFICE DIRECT AIR 0.369901
G NE APARTMENT DIRECT AIR 0.133081
G N1 APARTMENT DIRECT AIR 0.085085
G N2 APARTMENT DIRECT AIR 0.082757
G S1 APARTMENT DIRECT AIR 0.173383
G S2 APARTMENT DIRECT AIR 0.179946
F2 SW APARTMENT DIRECT AIR 0.320601
F2 NW APARTMENT DIRECT AIR 0.249230
F2 SE APARTMENT DIRECT AIR 0.316525
F2 NE APARTMENT DIRECT AIR 0.180108
F2 N1 APARTMENT DIRECT AIR 0.117439
F2 N2 APARTMENT DIRECT AIR 0.115348
F2 S1 APARTMENT DIRECT AIR 0.224299
F2 S2 APARTMENT DIRECT AIR 0.226702
F3 SW APARTMENT DIRECT AIR 0.324021
F3 NW APARTMENT DIRECT AIR 0.253134
F3 SE APARTMENT DIRECT AIR 0.299212
F3 NE APARTMENT DIRECT AIR 0.183989
F3 N1 APARTMENT DIRECT AIR 0.121699
F3 N2 APARTMENT DIRECT AIR 0.119602
F3 S1 APARTMENT DIRECT AIR 0.228575
F3 S2 APARTMENT DIRECT AIR 0.229704
F4 SW APARTMENT DIRECT AIR 0.326274
F4 NW APARTMENT DIRECT AIR 0.255260
F4 SE APARTMENT DIRECT AIR 0.299576
F4 NE APARTMENT DIRECT AIR 0.185258
F4 N1 APARTMENT DIRECT AIR 0.123609
F4 N2 APARTMENT DIRECT AIR 0.121510
F4 S1 APARTMENT DIRECT AIR 0.230553
F4 S2 APARTMENT DIRECT AIR 0.231499
M SW APARTMENT DIRECT AIR 0.330052
M NW APARTMENT DIRECT AIR 0.258978
M SE APARTMENT DIRECT AIR 0.303240
M NE APARTMENT DIRECT AIR 0.188225
M N1 APARTMENT DIRECT AIR 0.126887
M N2 APARTMENT DIRECT AIR 0.124786
M S1 APARTMENT DIRECT AIR 0.234010
M S2 APARTMENT DIRECT AIR 0.234925
F6 SW APARTMENT DIRECT AIR 0.327971
F6 NW APARTMENT DIRECT AIR 0.256787
F6 SE APARTMENT DIRECT AIR 0.301298
F6 NE APARTMENT DIRECT AIR 0.185565
F6 N1 APARTMENT DIRECT AIR 0.124669
F6 N2 APARTMENT DIRECT AIR 0.122581
F6 S1 APARTMENT DIRECT AIR 0.231712
F6 S2 APARTMENT DIRECT AIR 0.232623
F7 SW APARTMENT DIRECT AIR 0.327830
F7 NW APARTMENT DIRECT AIR 0.256568
F7 SE APARTMENT DIRECT AIR 0.301272
F7 NE APARTMENT DIRECT AIR 0.184887
F7 N1 APARTMENT DIRECT AIR 0.124316
F7 N2 APARTMENT DIRECT AIR 0.122271
F7 S1 APARTMENT DIRECT AIR 0.231349
F7 S2 APARTMENT DIRECT AIR 0.232256
F8 SW APARTMENT DIRECT AIR 0.328639
F8 NW APARTMENT DIRECT AIR 0.257361
F8 SE APARTMENT DIRECT AIR 0.302165
F8 NE APARTMENT DIRECT AIR 0.185199
F8 N1 APARTMENT DIRECT AIR 0.125006
F8 N2 APARTMENT DIRECT AIR 0.123023
F8 S1 APARTMENT DIRECT AIR 0.231961
F8 S2 APARTMENT DIRECT AIR 0.232869
F9 SW APARTMENT DIRECT AIR 0.336210
F9 NW APARTMENT DIRECT AIR 0.265354
F9 SE APARTMENT DIRECT AIR 0.308412
F9 NE APARTMENT DIRECT AIR 0.189087
F9 N1 APARTMENT DIRECT AIR 0.131998
F9 N2 APARTMENT DIRECT AIR 0.130000
F9 S1 APARTMENT DIRECT AIR 0.237087
F9 S2 APARTMENT DIRECT AIR 0.238110
T SW APARTMENT DIRECT AIR 0.411393
T NW APARTMENT DIRECT AIR 0.327253
T SE APARTMENT DIRECT AIR 0.375254
T NE APARTMENT DIRECT AIR 0.242352
T N1 APARTMENT DIRECT AIR 0.183666
T N2 APARTMENT DIRECT AIR 0.183462
T S1 APARTMENT DIRECT AIR 0.314125
T S2 APARTMENT DIRECT AIR 0.315091


Branch

Maximum Flow Rate [m3/s]
AIRLOOP G SW MAIN BRANCH 0.252777
AIRLOOP G NW MAIN BRANCH 0.194152
AIRLOOP OFFICE MAIN BRANCH 0.369901
AIRLOOP G NE MAIN BRANCH 0.133081
AIRLOOP G N1 MAIN BRANCH 0.085085
AIRLOOP G N2 MAIN BRANCH 0.082757
AIRLOOP G S1 MAIN BRANCH 0.173383
AIRLOOP G S2 MAIN BRANCH 0.179946
AIRLOOP F2 SW MAIN BRANCH 0.320601
AIRLOOP F2 NW MAIN BRANCH 0.249230
AIRLOOP F2 SE MAIN BRANCH 0.316525
AIRLOOP F2 NE MAIN BRANCH 0.180108
AIRLOOP F2 N1 MAIN BRANCH 0.117439
AIRLOOP F2 N2 MAIN BRANCH 0.115348
AIRLOOP F2 S1 MAIN BRANCH 0.224299
AIRLOOP F2 S2 MAIN BRANCH 0.226702
AIRLOOP F3 SW MAIN BRANCH 0.324021
AIRLOOP F3 NW MAIN BRANCH 0.253134
AIRLOOP F3 SE MAIN BRANCH 0.299212
AIRLOOP F3 NE MAIN BRANCH 0.183989
AIRLOOP F3 N1 MAIN BRANCH 0.121699
AIRLOOP F3 N2 MAIN BRANCH 0.119602
AIRLOOP F3 S1 MAIN BRANCH 0.228575
AIRLOOP F3 S2 MAIN BRANCH 0.229704
AIRLOOP F4 SW MAIN BRANCH 0.326274
AIRLOOP F4 NW MAIN BRANCH 0.255260
AIRLOOP F4 SE MAIN BRANCH 0.299576
AIRLOOP F4 NE MAIN BRANCH 0.185258
AIRLOOP F4 N1 MAIN BRANCH 0.123609
AIRLOOP F4 N2 MAIN BRANCH 0.121510
AIRLOOP F4 S1 MAIN BRANCH 0.230553
AIRLOOP F4 S2 MAIN BRANCH 0.231499
AIRLOOP M SW MAIN BRANCH 0.330052
AIRLOOP M NW MAIN BRANCH 0.258978
AIRLOOP M SE MAIN BRANCH 0.303240
AIRLOOP M NE MAIN BRANCH 0.188225
AIRLOOP M N1 MAIN BRANCH 0.126887
AIRLOOP M N2 MAIN BRANCH 0.124786
AIRLOOP M S1 MAIN BRANCH 0.234010
AIRLOOP M S2 MAIN BRANCH 0.234925
AIRLOOP F6 SW MAIN BRANCH 0.327971
AIRLOOP F6 NW MAIN BRANCH 0.256787
AIRLOOP F6 SE MAIN BRANCH 0.301298
AIRLOOP F6 NE MAIN BRANCH 0.185565
AIRLOOP F6 N1 MAIN BRANCH 0.124669
AIRLOOP F6 N2 MAIN BRANCH 0.122581
AIRLOOP F6 S1 MAIN BRANCH 0.231712
AIRLOOP F6 S2 MAIN BRANCH 0.232623
AIRLOOP F7 SW MAIN BRANCH 0.327830
AIRLOOP F7 NW MAIN BRANCH 0.256568
AIRLOOP F7 SE MAIN BRANCH 0.301272
AIRLOOP F7 NE MAIN BRANCH 0.184887
AIRLOOP F7 N1 MAIN BRANCH 0.124316
AIRLOOP F7 N2 MAIN BRANCH 0.122271
AIRLOOP F7 S1 MAIN BRANCH 0.231349
AIRLOOP F7 S2 MAIN BRANCH 0.232256
AIRLOOP F8 SW MAIN BRANCH 0.328639
AIRLOOP F8 NW MAIN BRANCH 0.257361
AIRLOOP F8 SE MAIN BRANCH 0.302165
AIRLOOP F8 NE MAIN BRANCH 0.185199
AIRLOOP F8 N1 MAIN BRANCH 0.125006
AIRLOOP F8 N2 MAIN BRANCH 0.123023
AIRLOOP F8 S1 MAIN BRANCH 0.231961
AIRLOOP F8 S2 MAIN BRANCH 0.232869
AIRLOOP F9 SW MAIN BRANCH 0.336210
AIRLOOP F9 NW MAIN BRANCH 0.265354
AIRLOOP F9 SE MAIN BRANCH 0.308412
AIRLOOP F9 NE MAIN BRANCH 0.189087
AIRLOOP F9 N1 MAIN BRANCH 0.131998
AIRLOOP F9 N2 MAIN BRANCH 0.130000
AIRLOOP F9 S1 MAIN BRANCH 0.237087
AIRLOOP F9 S2 MAIN BRANCH 0.238110
AIRLOOP T SW MAIN BRANCH 0.411393
AIRLOOP T NW MAIN BRANCH 0.327253
AIRLOOP T SE MAIN BRANCH 0.375254
AIRLOOP T NE MAIN BRANCH 0.242352
AIRLOOP T N1 MAIN BRANCH 0.183666
AIRLOOP T N2 MAIN BRANCH 0.183462
AIRLOOP T S1 MAIN BRANCH 0.314125
AIRLOOP T S2 MAIN BRANCH 0.315091


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
AIRLOOP G SW 0.252777
AIRLOOP G NW 0.194152
AIRLOOP OFFICE 0.369901
AIRLOOP G NE 0.133081
AIRLOOP G N1 0.085085
AIRLOOP G N2 0.082757
AIRLOOP G S1 0.173383
AIRLOOP G S2 0.179946
AIRLOOP F2 SW 0.320601
AIRLOOP F2 NW 0.249230
AIRLOOP F2 SE 0.316525
AIRLOOP F2 NE 0.180108
AIRLOOP F2 N1 0.117439
AIRLOOP F2 N2 0.115348
AIRLOOP F2 S1 0.224299
AIRLOOP F2 S2 0.226702
AIRLOOP F3 SW 0.324021
AIRLOOP F3 NW 0.253134
AIRLOOP F3 SE 0.299212
AIRLOOP F3 NE 0.183989
AIRLOOP F3 N1 0.121699
AIRLOOP F3 N2 0.119602
AIRLOOP F3 S1 0.228575
AIRLOOP F3 S2 0.229704
AIRLOOP F4 SW 0.326274
AIRLOOP F4 NW 0.255260
AIRLOOP F4 SE 0.299576
AIRLOOP F4 NE 0.185258
AIRLOOP F4 N1 0.123609
AIRLOOP F4 N2 0.121510
AIRLOOP F4 S1 0.230553
AIRLOOP F4 S2 0.231499
AIRLOOP M SW 0.330052
AIRLOOP M NW 0.258978
AIRLOOP M SE 0.303240
AIRLOOP M NE 0.188225
AIRLOOP M N1 0.126887
AIRLOOP M N2 0.124786
AIRLOOP M S1 0.234010
AIRLOOP M S2 0.234925
AIRLOOP F6 SW 0.327971
AIRLOOP F6 NW 0.256787
AIRLOOP F6 SE 0.301298
AIRLOOP F6 NE 0.185565
AIRLOOP F6 N1 0.124669
AIRLOOP F6 N2 0.122581
AIRLOOP F6 S1 0.231712
AIRLOOP F6 S2 0.232623
AIRLOOP F7 SW 0.327830
AIRLOOP F7 NW 0.256568
AIRLOOP F7 SE 0.301272
AIRLOOP F7 NE 0.184887
AIRLOOP F7 N1 0.124316
AIRLOOP F7 N2 0.122271
AIRLOOP F7 S1 0.231349
AIRLOOP F7 S2 0.232256
AIRLOOP F8 SW 0.328639
AIRLOOP F8 NW 0.257361
AIRLOOP F8 SE 0.302165
AIRLOOP F8 NE 0.185199
AIRLOOP F8 N1 0.125006
AIRLOOP F8 N2 0.123023
AIRLOOP F8 S1 0.231961
AIRLOOP F8 S2 0.232869
AIRLOOP F9 SW 0.336210
AIRLOOP F9 NW 0.265354
AIRLOOP F9 SE 0.308412
AIRLOOP F9 NE 0.189087
AIRLOOP F9 N1 0.131998
AIRLOOP F9 N2 0.130000
AIRLOOP F9 S1 0.237087
AIRLOOP F9 S2 0.238110
AIRLOOP T SW 0.411393
AIRLOOP T NW 0.327253
AIRLOOP T SE 0.375254
AIRLOOP T NE 0.242352
AIRLOOP T N1 0.183666
AIRLOOP T N2 0.183462
AIRLOOP T S1 0.314125
AIRLOOP T S2 0.315091


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
AIRLOOP G SW OA CONTROLLER 0.252777 0.025952
AIRLOOP G NW OA CONTROLLER 0.194152 0.025952
AIRLOOP OFFICE OA CONTROLLER 0.369901 0.038103
AIRLOOP G NE OA CONTROLLER 0.133081 0.025952
AIRLOOP G N1 OA CONTROLLER 0.085085 0.025952
AIRLOOP G N2 OA CONTROLLER 0.082757 0.025952
AIRLOOP G S1 OA CONTROLLER 0.173383 0.025952
AIRLOOP G S2 OA CONTROLLER 0.179946 0.025952
AIRLOOP F2 SW OA CONTROLLER 0.320601 0.025952
AIRLOOP F2 NW OA CONTROLLER 0.249230 0.025952
AIRLOOP F2 SE OA CONTROLLER 0.316525 0.025952
AIRLOOP F2 NE OA CONTROLLER 0.180108 0.025952
AIRLOOP F2 N1 OA CONTROLLER 0.117439 0.025952
AIRLOOP F2 N2 OA CONTROLLER 0.115348 0.025952
AIRLOOP F2 S1 OA CONTROLLER 0.224299 0.025952
AIRLOOP F2 S2 OA CONTROLLER 0.226702 0.025952
AIRLOOP F3 SW OA CONTROLLER 0.324021 0.025952
AIRLOOP F3 NW OA CONTROLLER 0.253134 0.025952
AIRLOOP F3 SE OA CONTROLLER 0.299212 0.025952
AIRLOOP F3 NE OA CONTROLLER 0.183989 0.025952
AIRLOOP F3 N1 OA CONTROLLER 0.121699 0.025952
AIRLOOP F3 N2 OA CONTROLLER 0.119602 0.025952
AIRLOOP F3 S1 OA CONTROLLER 0.228575 0.025952
AIRLOOP F3 S2 OA CONTROLLER 0.229704 0.025952
AIRLOOP F4 SW OA CONTROLLER 0.326274 0.025952
AIRLOOP F4 NW OA CONTROLLER 0.255260 0.025952
AIRLOOP F4 SE OA CONTROLLER 0.299576 0.025952
AIRLOOP F4 NE OA CONTROLLER 0.185258 0.025952
AIRLOOP F4 N1 OA CONTROLLER 0.123609 0.025952
AIRLOOP F4 N2 OA CONTROLLER 0.121510 0.025952
AIRLOOP F4 S1 OA CONTROLLER 0.230553 0.025952
AIRLOOP F4 S2 OA CONTROLLER 0.231499 0.025952
AIRLOOP M SW OA CONTROLLER 0.330052 0.025952
AIRLOOP M NW OA CONTROLLER 0.258978 0.025952
AIRLOOP M SE OA CONTROLLER 0.303240 0.025952
AIRLOOP M NE OA CONTROLLER 0.188225 0.025952
AIRLOOP M N1 OA CONTROLLER 0.126887 0.025952
AIRLOOP M N2 OA CONTROLLER 0.124786 0.025952
AIRLOOP M S1 OA CONTROLLER 0.234010 0.025952
AIRLOOP M S2 OA CONTROLLER 0.234925 0.025952
AIRLOOP F6 SW OA CONTROLLER 0.327971 0.025952
AIRLOOP F6 NW OA CONTROLLER 0.256787 0.025952
AIRLOOP F6 SE OA CONTROLLER 0.301298 0.025952
AIRLOOP F6 NE OA CONTROLLER 0.185565 0.025952
AIRLOOP F6 N1 OA CONTROLLER 0.124669 0.025952
AIRLOOP F6 N2 OA CONTROLLER 0.122581 0.025952
AIRLOOP F6 S1 OA CONTROLLER 0.231712 0.025952
AIRLOOP F6 S2 OA CONTROLLER 0.232623 0.025952
AIRLOOP F7 SW OA CONTROLLER 0.327830 0.025952
AIRLOOP F7 NW OA CONTROLLER 0.256568 0.025952
AIRLOOP F7 SE OA CONTROLLER 0.301272 0.025952
AIRLOOP F7 NE OA CONTROLLER 0.184887 0.025952
AIRLOOP F7 N1 OA CONTROLLER 0.124316 0.025952
AIRLOOP F7 N2 OA CONTROLLER 0.122271 0.025952
AIRLOOP F7 S1 OA CONTROLLER 0.231349 0.025952
AIRLOOP F7 S2 OA CONTROLLER 0.232256 0.025952
AIRLOOP F8 SW OA CONTROLLER 0.328639 0.025952
AIRLOOP F8 NW OA CONTROLLER 0.257361 0.025952
AIRLOOP F8 SE OA CONTROLLER 0.302165 0.025952
AIRLOOP F8 NE OA CONTROLLER 0.185199 0.025952
AIRLOOP F8 N1 OA CONTROLLER 0.125006 0.025952
AIRLOOP F8 N2 OA CONTROLLER 0.123023 0.025952
AIRLOOP F8 S1 OA CONTROLLER 0.231961 0.025952
AIRLOOP F8 S2 OA CONTROLLER 0.232869 0.025952
AIRLOOP F9 SW OA CONTROLLER 0.336210 0.025952
AIRLOOP F9 NW OA CONTROLLER 0.265354 0.025952
AIRLOOP F9 SE OA CONTROLLER 0.308412 0.025952
AIRLOOP F9 NE OA CONTROLLER 0.189087 0.025952
AIRLOOP F9 N1 OA CONTROLLER 0.131998 0.025952
AIRLOOP F9 N2 OA CONTROLLER 0.130000 0.025952
AIRLOOP F9 S1 OA CONTROLLER 0.237087 0.025952
AIRLOOP F9 S2 OA CONTROLLER 0.238110 0.025952
AIRLOOP T SW OA CONTROLLER 0.411393 0.025952
AIRLOOP T NW OA CONTROLLER 0.327253 0.025952
AIRLOOP T SE OA CONTROLLER 0.375254 0.025952
AIRLOOP T NE OA CONTROLLER 0.242352 0.025952
AIRLOOP T N1 OA CONTROLLER 0.183666 0.025952
AIRLOOP T N2 OA CONTROLLER 0.183462 0.025952
AIRLOOP T S1 OA CONTROLLER 0.314125 0.025952
AIRLOOP T S2 OA CONTROLLER 0.315091 0.025952


COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity [W] Rated Sensible Cooling Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP COOLING MODE AIRLOOP G SW 0.252777 3842.70 2880.51 0.000084
HEAT PUMP COOLING MODE AIRLOOP G NW 0.194152 2958.00 2210.06 0.000065
HEAT PUMP COOLING MODE AIRLOOP OFFICE 0.369901 5610.84 4216.33 0.000123
HEAT PUMP COOLING MODE AIRLOOP G NE 0.133081 2057.38 1525.06 0.000045
HEAT PUMP COOLING MODE AIRLOOP G N1 0.085085 1364.06 992.65 0.000030
HEAT PUMP COOLING MODE AIRLOOP G N2 0.082757 1330.50 967.03 0.000029
HEAT PUMP COOLING MODE AIRLOOP G S1 0.173383 2739.68 2020.41 0.000060
HEAT PUMP COOLING MODE AIRLOOP G S2 0.179946 2831.51 2091.98 0.000062
HEAT PUMP COOLING MODE AIRLOOP F2 SW 0.320601 4798.55 3620.45 0.000105
HEAT PUMP COOLING MODE AIRLOOP F2 NW 0.249230 3737.58 2811.66 0.000082
HEAT PUMP COOLING MODE AIRLOOP F2 SE 0.316525 4756.20 3582.98 0.000104
HEAT PUMP COOLING MODE AIRLOOP F2 NE 0.180108 2718.42 2037.52 0.000059
HEAT PUMP COOLING MODE AIRLOOP F2 N1 0.117439 1827.42 1347.69 0.000040
HEAT PUMP COOLING MODE AIRLOOP F2 N2 0.115348 1797.53 1324.77 0.000039
HEAT PUMP COOLING MODE AIRLOOP F2 S1 0.224299 3462.18 2579.09 0.000076
HEAT PUMP COOLING MODE AIRLOOP F2 S2 0.226702 3495.78 2605.27 0.000076
HEAT PUMP COOLING MODE AIRLOOP F3 SW 0.324021 4850.94 3658.87 0.000106
HEAT PUMP COOLING MODE AIRLOOP F3 NW 0.253134 3796.43 2855.25 0.000083
HEAT PUMP COOLING MODE AIRLOOP F3 SE 0.299212 4518.65 3395.82 0.000099
HEAT PUMP COOLING MODE AIRLOOP F3 NE 0.183989 2776.34 2080.71 0.000061
HEAT PUMP COOLING MODE AIRLOOP F3 N1 0.121699 1889.62 1394.74 0.000041
HEAT PUMP COOLING MODE AIRLOOP F3 N2 0.119602 1859.66 1371.75 0.000041
HEAT PUMP COOLING MODE AIRLOOP F3 S1 0.228575 3524.66 2626.38 0.000077
HEAT PUMP COOLING MODE AIRLOOP F3 S2 0.229704 3540.44 2638.67 0.000077
HEAT PUMP COOLING MODE AIRLOOP F4 SW 0.326274 4885.85 3684.28 0.000107
HEAT PUMP COOLING MODE AIRLOOP F4 NW 0.255260 3829.31 2879.22 0.000084
HEAT PUMP COOLING MODE AIRLOOP F4 SE 0.299576 4527.09 3400.67 0.000099
HEAT PUMP COOLING MODE AIRLOOP F4 NE 0.185258 2812.66 2102.94 0.000061
HEAT PUMP COOLING MODE AIRLOOP F4 N1 0.123609 1918.03 1415.97 0.000042
HEAT PUMP COOLING MODE AIRLOOP F4 N2 0.121510 1888.04 1392.97 0.000041
HEAT PUMP COOLING MODE AIRLOOP F4 S1 0.230553 3554.33 2648.46 0.000078
HEAT PUMP COOLING MODE AIRLOOP F4 S2 0.231499 3567.55 2658.75 0.000078
HEAT PUMP COOLING MODE AIRLOOP M SW 0.330052 4941.44 3726.11 0.000108
HEAT PUMP COOLING MODE AIRLOOP M NW 0.258978 3892.61 2925.00 0.000085
HEAT PUMP COOLING MODE AIRLOOP M SE 0.303240 4581.05 3441.26 0.000100
HEAT PUMP COOLING MODE AIRLOOP M NE 0.188225 2856.48 2135.83 0.000062
HEAT PUMP COOLING MODE AIRLOOP M N1 0.126887 1965.64 1452.11 0.000043
HEAT PUMP COOLING MODE AIRLOOP M N2 0.124786 1935.64 1429.09 0.000042
HEAT PUMP COOLING MODE AIRLOOP M S1 0.234010 3604.33 2686.55 0.000079
HEAT PUMP COOLING MODE AIRLOOP M S2 0.234925 3617.14 2696.52 0.000079
HEAT PUMP COOLING MODE AIRLOOP F6 SW 0.327971 4914.69 3704.10 0.000107
HEAT PUMP COOLING MODE AIRLOOP F6 NW 0.256787 3863.98 2901.70 0.000084
HEAT PUMP COOLING MODE AIRLOOP F6 SE 0.301298 4556.18 3420.75 0.000100
HEAT PUMP COOLING MODE AIRLOOP F6 NE 0.185565 2821.07 2107.38 0.000062
HEAT PUMP COOLING MODE AIRLOOP F6 N1 0.124669 1935.01 1428.09 0.000042
HEAT PUMP COOLING MODE AIRLOOP F6 N2 0.122581 1905.17 1405.21 0.000042
HEAT PUMP COOLING MODE AIRLOOP F6 S1 0.231712 3573.54 2661.88 0.000078
HEAT PUMP COOLING MODE AIRLOOP F6 S2 0.232623 3586.28 2671.80 0.000078
HEAT PUMP COOLING MODE AIRLOOP F7 SW 0.327830 4914.77 3703.11 0.000107
HEAT PUMP COOLING MODE AIRLOOP F7 NW 0.256568 3862.75 2899.82 0.000084
HEAT PUMP COOLING MODE AIRLOOP F7 SE 0.301272 4557.80 3420.99 0.000100
HEAT PUMP COOLING MODE AIRLOOP F7 NE 0.184887 2813.19 2100.44 0.000061
HEAT PUMP COOLING MODE AIRLOOP F7 N1 0.124316 1930.76 1424.44 0.000042
HEAT PUMP COOLING MODE AIRLOOP F7 N2 0.122271 1913.34 1408.52 0.000042
HEAT PUMP COOLING MODE AIRLOOP F7 S1 0.231349 3569.66 2658.25 0.000078
HEAT PUMP COOLING MODE AIRLOOP F7 S2 0.232256 3582.35 2668.13 0.000078
HEAT PUMP COOLING MODE AIRLOOP F8 SW 0.328639 4927.92 3712.40 0.000108
HEAT PUMP COOLING MODE AIRLOOP F8 NW 0.257361 3875.52 2908.90 0.000085
HEAT PUMP COOLING MODE AIRLOOP F8 SE 0.302165 4572.10 3431.20 0.000100
HEAT PUMP COOLING MODE AIRLOOP F8 NE 0.185199 2819.01 2104.23 0.000062
HEAT PUMP COOLING MODE AIRLOOP F8 N1 0.125006 1941.26 1432.18 0.000042
HEAT PUMP COOLING MODE AIRLOOP F8 N2 0.123023 1924.71 1416.93 0.000042
HEAT PUMP COOLING MODE AIRLOOP F8 S1 0.231961 3579.31 2665.20 0.000078
HEAT PUMP COOLING MODE AIRLOOP F8 S2 0.232869 3592.01 2675.10 0.000078
HEAT PUMP COOLING MODE AIRLOOP F9 SW 0.336210 5035.56 3795.22 0.000110
HEAT PUMP COOLING MODE AIRLOOP F9 NW 0.265354 3989.25 2996.34 0.000087
HEAT PUMP COOLING MODE AIRLOOP F9 SE 0.308412 4666.71 3502.23 0.000102
HEAT PUMP COOLING MODE AIRLOOP F9 NE 0.189087 2992.31 2201.53 0.000065
HEAT PUMP COOLING MODE AIRLOOP F9 N1 0.131998 2041.36 1508.85 0.000045
HEAT PUMP COOLING MODE AIRLOOP F9 N2 0.130000 2024.47 1493.44 0.000044
HEAT PUMP COOLING MODE AIRLOOP F9 S1 0.237087 3652.14 2721.33 0.000080
HEAT PUMP COOLING MODE AIRLOOP F9 S2 0.238110 3666.45 2732.47 0.000080
HEAT PUMP COOLING MODE AIRLOOP T SW 0.411393 6102.07 4619.74 0.000133
HEAT PUMP COOLING MODE AIRLOOP T NW 0.327253 4880.66 3682.92 0.000107
HEAT PUMP COOLING MODE AIRLOOP T SE 0.375254 5597.95 4227.27 0.000122
HEAT PUMP COOLING MODE AIRLOOP T NE 0.242352 3742.16 2783.06 0.000082
HEAT PUMP COOLING MODE AIRLOOP T N1 0.183666 2896.99 2135.96 0.000063
HEAT PUMP COOLING MODE AIRLOOP T N2 0.183462 2900.88 2136.76 0.000063
HEAT PUMP COOLING MODE AIRLOOP T S1 0.314125 4725.45 3557.61 0.000103
HEAT PUMP COOLING MODE AIRLOOP T S2 0.315091 4738.94 3568.13 0.000104


AirLoopHVAC:UnitaryHeatPump:WaterToAir

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Supplemental Heating Coil Nominal Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
AIRLOOP G SW DXAC HEAT PUMP 0.252777 0.252777 0.252777 0.252777 3842.70 3842.70 2633.20 1.00
AIRLOOP G NW DXAC HEAT PUMP 0.194152 0.194152 0.194152 0.194152 2958.00 2958.00 2633.31 1.00
AIRLOOP OFFICE DXAC HEAT PUMP 0.369901 0.369901 0.369901 0.369901 5610.84 5610.84 3380.53 1.00
AIRLOOP G NE DXAC HEAT PUMP 0.133081 0.133081 0.133081 0.133081 2057.38 2057.38 2633.31 1.00
AIRLOOP G N1 DXAC HEAT PUMP 0.085085 0.085085 0.085085 0.085085 1364.06 1364.06 2008.22 1.00
AIRLOOP G N2 DXAC HEAT PUMP 0.082757 0.082757 0.082757 0.082757 1330.50 1330.50 2008.22 1.00
AIRLOOP G S1 DXAC HEAT PUMP 0.173383 0.173383 0.173383 0.173383 2739.68 2739.68 2004.40 1.00
AIRLOOP G S2 DXAC HEAT PUMP 0.179946 0.179946 0.179946 0.179946 2831.51 2831.51 2010.69 1.00
AIRLOOP F2 SW DXAC HEAT PUMP 0.320601 0.320601 0.320601 0.320601 4798.55 4798.55 2528.11 1.00
AIRLOOP F2 NW DXAC HEAT PUMP 0.249230 0.249230 0.249230 0.249230 3737.58 3737.58 2523.45 1.00
AIRLOOP F2 SE DXAC HEAT PUMP 0.316525 0.316525 0.316525 0.316525 4756.20 4756.20 2546.88 1.00
AIRLOOP F2 NE DXAC HEAT PUMP 0.180108 0.180108 0.180108 0.180108 2718.42 2718.42 2523.45 1.00
AIRLOOP F2 N1 DXAC HEAT PUMP 0.117439 0.117439 0.117439 0.117439 1827.42 1827.42 1755.15 1.00
AIRLOOP F2 N2 DXAC HEAT PUMP 0.115348 0.115348 0.115348 0.115348 1797.53 1797.53 1755.15 1.00
AIRLOOP F2 S1 DXAC HEAT PUMP 0.224299 0.224299 0.224299 0.224299 3462.18 3462.18 1762.58 1.00
AIRLOOP F2 S2 DXAC HEAT PUMP 0.226702 0.226702 0.226702 0.226702 3495.78 3495.78 1763.83 1.00
AIRLOOP F3 SW DXAC HEAT PUMP 0.324021 0.324021 0.324021 0.324021 4850.94 4850.94 2515.86 1.00
AIRLOOP F3 NW DXAC HEAT PUMP 0.253134 0.253134 0.253134 0.253134 3796.43 3796.43 2512.54 1.00
AIRLOOP F3 SE DXAC HEAT PUMP 0.299212 0.299212 0.299212 0.299212 4518.65 4518.65 2517.97 1.00
AIRLOOP F3 NE DXAC HEAT PUMP 0.183989 0.183989 0.183989 0.183989 2776.34 2776.34 2512.54 1.00
AIRLOOP F3 N1 DXAC HEAT PUMP 0.121699 0.121699 0.121699 0.121699 1889.62 1889.62 1712.12 1.00
AIRLOOP F3 N2 DXAC HEAT PUMP 0.119602 0.119602 0.119602 0.119602 1859.66 1859.66 1712.12 1.00
AIRLOOP F3 S1 DXAC HEAT PUMP 0.228575 0.228575 0.228575 0.228575 3524.66 3524.66 1716.20 1.00
AIRLOOP F3 S2 DXAC HEAT PUMP 0.229704 0.229704 0.229704 0.229704 3540.44 3540.44 1716.40 1.00
AIRLOOP F4 SW DXAC HEAT PUMP 0.326274 0.326274 0.326274 0.326274 4885.85 4885.85 2554.64 1.00
AIRLOOP F4 NW DXAC HEAT PUMP 0.255260 0.255260 0.255260 0.255260 3829.31 3829.31 2552.57 1.00
AIRLOOP F4 SE DXAC HEAT PUMP 0.299576 0.299576 0.299576 0.299576 4527.09 4527.09 2554.87 1.00
AIRLOOP F4 NE DXAC HEAT PUMP 0.185258 0.185258 0.185258 0.185258 2812.66 2812.66 2552.57 1.00
AIRLOOP F4 N1 DXAC HEAT PUMP 0.123609 0.123609 0.123609 0.123609 1918.03 1918.03 1725.84 1.00
AIRLOOP F4 N2 DXAC HEAT PUMP 0.121510 0.121510 0.121510 0.121510 1888.04 1888.04 1725.84 1.00
AIRLOOP F4 S1 DXAC HEAT PUMP 0.230553 0.230553 0.230553 0.230553 3554.33 3554.33 1728.44 1.00
AIRLOOP F4 S2 DXAC HEAT PUMP 0.231499 0.231499 0.231499 0.231499 3567.55 3567.55 1728.47 1.00
AIRLOOP M SW DXAC HEAT PUMP 0.330052 0.330052 0.330052 0.330052 4941.44 4941.44 2574.82 1.00
AIRLOOP M NW DXAC HEAT PUMP 0.258978 0.258978 0.258978 0.258978 3892.61 3892.61 2572.63 1.00
AIRLOOP M SE DXAC HEAT PUMP 0.303240 0.303240 0.303240 0.303240 4581.05 4581.05 2574.84 1.00
AIRLOOP M NE DXAC HEAT PUMP 0.188225 0.188225 0.188225 0.188225 2856.48 2856.48 2572.63 1.00
AIRLOOP M N1 DXAC HEAT PUMP 0.126887 0.126887 0.126887 0.126887 1965.64 1965.64 1726.94 1.00
AIRLOOP M N2 DXAC HEAT PUMP 0.124786 0.124786 0.124786 0.124786 1935.64 1935.64 1726.94 1.00
AIRLOOP M S1 DXAC HEAT PUMP 0.234010 0.234010 0.234010 0.234010 3604.33 3604.33 1729.62 1.00
AIRLOOP M S2 DXAC HEAT PUMP 0.234925 0.234925 0.234925 0.234925 3617.14 3617.14 1729.63 1.00
AIRLOOP F6 SW DXAC HEAT PUMP 0.327971 0.327971 0.327971 0.327971 4914.69 4914.69 2653.56 1.00
AIRLOOP F6 NW DXAC HEAT PUMP 0.256787 0.256787 0.256787 0.256787 3863.98 3863.98 2652.81 1.00
AIRLOOP F6 SE DXAC HEAT PUMP 0.301298 0.301298 0.301298 0.301298 4556.18 4556.18 2653.56 1.00
AIRLOOP F6 NE DXAC HEAT PUMP 0.185565 0.185565 0.185565 0.185565 2821.07 2821.07 2652.81 1.00
AIRLOOP F6 N1 DXAC HEAT PUMP 0.124669 0.124669 0.124669 0.124669 1935.01 1935.01 1786.44 1.00
AIRLOOP F6 N2 DXAC HEAT PUMP 0.122581 0.122581 0.122581 0.122581 1905.17 1905.17 1786.44 1.00
AIRLOOP F6 S1 DXAC HEAT PUMP 0.231712 0.231712 0.231712 0.231712 3573.54 3573.54 1787.61 1.00
AIRLOOP F6 S2 DXAC HEAT PUMP 0.232623 0.232623 0.232623 0.232623 3586.28 3586.28 1787.61 1.00
AIRLOOP F7 SW DXAC HEAT PUMP 0.327830 0.327830 0.327830 0.327830 4914.77 4914.77 2706.80 1.00
AIRLOOP F7 NW DXAC HEAT PUMP 0.256568 0.256568 0.256568 0.256568 3862.75 3862.75 2706.44 1.00
AIRLOOP F7 SE DXAC HEAT PUMP 0.301272 0.301272 0.301272 0.301272 4557.80 4557.80 2706.80 1.00
AIRLOOP F7 NE DXAC HEAT PUMP 0.184887 0.184887 0.184887 0.184887 2813.19 2813.19 2706.44 1.00
AIRLOOP F7 N1 DXAC HEAT PUMP 0.124316 0.124316 0.124316 0.124316 1930.76 1930.76 1824.23 1.00
AIRLOOP F7 N2 DXAC HEAT PUMP 0.122271 0.122271 0.122271 0.122271 1913.34 1913.34 1824.23 1.00
AIRLOOP F7 S1 DXAC HEAT PUMP 0.231349 0.231349 0.231349 0.231349 3569.66 3569.66 1825.03 1.00
AIRLOOP F7 S2 DXAC HEAT PUMP 0.232256 0.232256 0.232256 0.232256 3582.35 3582.35 1825.03 1.00
AIRLOOP F8 SW DXAC HEAT PUMP 0.328639 0.328639 0.328639 0.328639 4927.92 4927.92 2764.07 1.00
AIRLOOP F8 NW DXAC HEAT PUMP 0.257361 0.257361 0.257361 0.257361 3875.52 3875.52 2763.83 1.00
AIRLOOP F8 SE DXAC HEAT PUMP 0.302165 0.302165 0.302165 0.302165 4572.10 4572.10 2764.07 1.00
AIRLOOP F8 NE DXAC HEAT PUMP 0.185199 0.185199 0.185199 0.185199 2819.01 2819.01 2763.83 1.00
AIRLOOP F8 N1 DXAC HEAT PUMP 0.125006 0.125006 0.125006 0.125006 1941.26 1941.26 1867.67 1.00
AIRLOOP F8 N2 DXAC HEAT PUMP 0.123023 0.123023 0.123023 0.123023 1924.71 1924.71 1867.67 1.00
AIRLOOP F8 S1 DXAC HEAT PUMP 0.231961 0.231961 0.231961 0.231961 3579.31 3579.31 1868.32 1.00
AIRLOOP F8 S2 DXAC HEAT PUMP 0.232869 0.232869 0.232869 0.232869 3592.01 3592.01 1868.32 1.00
AIRLOOP F9 SW DXAC HEAT PUMP 0.336210 0.336210 0.336210 0.336210 5035.56 5035.56 2934.65 1.00
AIRLOOP F9 NW DXAC HEAT PUMP 0.265354 0.265354 0.265354 0.265354 3989.25 3989.25 2932.49 1.00
AIRLOOP F9 SE DXAC HEAT PUMP 0.308412 0.308412 0.308412 0.308412 4666.71 4666.71 2934.65 1.00
AIRLOOP F9 NE DXAC HEAT PUMP 0.189087 0.189087 0.189087 0.189087 2992.31 2992.31 2932.49 1.00
AIRLOOP F9 N1 DXAC HEAT PUMP 0.131998 0.131998 0.131998 0.131998 2041.36 2041.36 2016.33 1.00
AIRLOOP F9 N2 DXAC HEAT PUMP 0.130000 0.130000 0.130000 0.130000 2024.47 2024.47 2016.33 1.00
AIRLOOP F9 S1 DXAC HEAT PUMP 0.237087 0.237087 0.237087 0.237087 3652.14 3652.14 2018.46 1.00
AIRLOOP F9 S2 DXAC HEAT PUMP 0.238110 0.238110 0.238110 0.238110 3666.45 3666.45 2018.46 1.00
AIRLOOP T SW DXAC HEAT PUMP 0.411393 0.411393 0.411393 0.411393 6102.07 6102.07 3525.16 1.00
AIRLOOP T NW DXAC HEAT PUMP 0.327253 0.327253 0.327253 0.327253 4880.66 4880.66 3529.64 1.00
AIRLOOP T SE DXAC HEAT PUMP 0.375254 0.375254 0.375254 0.375254 5597.95 5597.95 3525.16 1.00
AIRLOOP T NE DXAC HEAT PUMP 0.242352 0.242352 0.242352 0.242352 3742.16 3742.16 3529.64 1.00
AIRLOOP T N1 DXAC HEAT PUMP 0.183666 0.183666 0.183666 0.183666 2896.99 2896.99 2650.04 1.00
AIRLOOP T N2 DXAC HEAT PUMP 0.183462 0.183462 0.183462 0.183462 2900.88 2900.88 2650.04 1.00
AIRLOOP T S1 DXAC HEAT PUMP 0.314125 0.314125 0.314125 0.314125 4725.45 4725.45 2642.57 1.00
AIRLOOP T S2 DXAC HEAT PUMP 0.315091 0.315091 0.315091 0.315091 4738.94 4738.94 2642.57 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
AIRLOOP G SW SUPPLY FAN 0.252777
AIRLOOP G NW SUPPLY FAN 0.194152
AIRLOOP OFFICE SUPPLY FAN 0.369901
AIRLOOP G NE SUPPLY FAN 0.133081
AIRLOOP G N1 SUPPLY FAN 0.085085
AIRLOOP G N2 SUPPLY FAN 0.082757
AIRLOOP G S1 SUPPLY FAN 0.173383
AIRLOOP G S2 SUPPLY FAN 0.179946
AIRLOOP F2 SW SUPPLY FAN 0.320601
AIRLOOP F2 NW SUPPLY FAN 0.249230
AIRLOOP F2 SE SUPPLY FAN 0.316525
AIRLOOP F2 NE SUPPLY FAN 0.180108
AIRLOOP F2 N1 SUPPLY FAN 0.117439
AIRLOOP F2 N2 SUPPLY FAN 0.115348
AIRLOOP F2 S1 SUPPLY FAN 0.224299
AIRLOOP F2 S2 SUPPLY FAN 0.226702
AIRLOOP F3 SW SUPPLY FAN 0.324021
AIRLOOP F3 NW SUPPLY FAN 0.253134
AIRLOOP F3 SE SUPPLY FAN 0.299212
AIRLOOP F3 NE SUPPLY FAN 0.183989
AIRLOOP F3 N1 SUPPLY FAN 0.121699
AIRLOOP F3 N2 SUPPLY FAN 0.119602
AIRLOOP F3 S1 SUPPLY FAN 0.228575
AIRLOOP F3 S2 SUPPLY FAN 0.229704
AIRLOOP F4 SW SUPPLY FAN 0.326274
AIRLOOP F4 NW SUPPLY FAN 0.255260
AIRLOOP F4 SE SUPPLY FAN 0.299576
AIRLOOP F4 NE SUPPLY FAN 0.185258
AIRLOOP F4 N1 SUPPLY FAN 0.123609
AIRLOOP F4 N2 SUPPLY FAN 0.121510
AIRLOOP F4 S1 SUPPLY FAN 0.230553
AIRLOOP F4 S2 SUPPLY FAN 0.231499
AIRLOOP M SW SUPPLY FAN 0.330052
AIRLOOP M NW SUPPLY FAN 0.258978
AIRLOOP M SE SUPPLY FAN 0.303240
AIRLOOP M NE SUPPLY FAN 0.188225
AIRLOOP M N1 SUPPLY FAN 0.126887
AIRLOOP M N2 SUPPLY FAN 0.124786
AIRLOOP M S1 SUPPLY FAN 0.234010
AIRLOOP M S2 SUPPLY FAN 0.234925
AIRLOOP F6 SW SUPPLY FAN 0.327971
AIRLOOP F6 NW SUPPLY FAN 0.256787
AIRLOOP F6 SE SUPPLY FAN 0.301298
AIRLOOP F6 NE SUPPLY FAN 0.185565
AIRLOOP F6 N1 SUPPLY FAN 0.124669
AIRLOOP F6 N2 SUPPLY FAN 0.122581
AIRLOOP F6 S1 SUPPLY FAN 0.231712
AIRLOOP F6 S2 SUPPLY FAN 0.232623
AIRLOOP F7 SW SUPPLY FAN 0.327830
AIRLOOP F7 NW SUPPLY FAN 0.256568
AIRLOOP F7 SE SUPPLY FAN 0.301272
AIRLOOP F7 NE SUPPLY FAN 0.184887
AIRLOOP F7 N1 SUPPLY FAN 0.124316
AIRLOOP F7 N2 SUPPLY FAN 0.122271
AIRLOOP F7 S1 SUPPLY FAN 0.231349
AIRLOOP F7 S2 SUPPLY FAN 0.232256
AIRLOOP F8 SW SUPPLY FAN 0.328639
AIRLOOP F8 NW SUPPLY FAN 0.257361
AIRLOOP F8 SE SUPPLY FAN 0.302165
AIRLOOP F8 NE SUPPLY FAN 0.185199
AIRLOOP F8 N1 SUPPLY FAN 0.125006
AIRLOOP F8 N2 SUPPLY FAN 0.123023
AIRLOOP F8 S1 SUPPLY FAN 0.231961
AIRLOOP F8 S2 SUPPLY FAN 0.232869
AIRLOOP F9 SW SUPPLY FAN 0.336210
AIRLOOP F9 NW SUPPLY FAN 0.265354
AIRLOOP F9 SE SUPPLY FAN 0.308412
AIRLOOP F9 NE SUPPLY FAN 0.189087
AIRLOOP F9 N1 SUPPLY FAN 0.131998
AIRLOOP F9 N2 SUPPLY FAN 0.130000
AIRLOOP F9 S1 SUPPLY FAN 0.237087
AIRLOOP F9 S2 SUPPLY FAN 0.238110
AIRLOOP T SW SUPPLY FAN 0.411393
AIRLOOP T NW SUPPLY FAN 0.327253
AIRLOOP T SE SUPPLY FAN 0.375254
AIRLOOP T NE SUPPLY FAN 0.242352
AIRLOOP T N1 SUPPLY FAN 0.183666
AIRLOOP T N2 SUPPLY FAN 0.183462
AIRLOOP T S1 SUPPLY FAN 0.314125
AIRLOOP T S2 SUPPLY FAN 0.315091


COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Heating Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP HEATING MODE AIRLOOP G SW 0.252777 3842.70 0.000084
HEAT PUMP HEATING MODE AIRLOOP G NW 0.194152 2958.00 0.000065
HEAT PUMP HEATING MODE AIRLOOP OFFICE 0.369901 5610.84 0.000123
HEAT PUMP HEATING MODE AIRLOOP G NE 0.133081 2057.38 0.000045
HEAT PUMP HEATING MODE AIRLOOP G N1 0.085085 1364.06 0.000030
HEAT PUMP HEATING MODE AIRLOOP G N2 0.082757 1330.50 0.000029
HEAT PUMP HEATING MODE AIRLOOP G S1 0.173383 2739.68 0.000060
HEAT PUMP HEATING MODE AIRLOOP G S2 0.179946 2831.51 0.000062
HEAT PUMP HEATING MODE AIRLOOP F2 SW 0.320601 4798.55 0.000105
HEAT PUMP HEATING MODE AIRLOOP F2 NW 0.249230 3737.58 0.000082
HEAT PUMP HEATING MODE AIRLOOP F2 SE 0.316525 4756.20 0.000104
HEAT PUMP HEATING MODE AIRLOOP F2 NE 0.180108 2718.42 0.000059
HEAT PUMP HEATING MODE AIRLOOP F2 N1 0.117439 1827.42 0.000040
HEAT PUMP HEATING MODE AIRLOOP F2 N2 0.115348 1797.53 0.000039
HEAT PUMP HEATING MODE AIRLOOP F2 S1 0.224299 3462.18 0.000076
HEAT PUMP HEATING MODE AIRLOOP F2 S2 0.226702 3495.78 0.000076
HEAT PUMP HEATING MODE AIRLOOP F3 SW 0.324021 4850.94 0.000106
HEAT PUMP HEATING MODE AIRLOOP F3 NW 0.253134 3796.43 0.000083
HEAT PUMP HEATING MODE AIRLOOP F3 SE 0.299212 4518.65 0.000099
HEAT PUMP HEATING MODE AIRLOOP F3 NE 0.183989 2776.34 0.000061
HEAT PUMP HEATING MODE AIRLOOP F3 N1 0.121699 1889.62 0.000041
HEAT PUMP HEATING MODE AIRLOOP F3 N2 0.119602 1859.66 0.000041
HEAT PUMP HEATING MODE AIRLOOP F3 S1 0.228575 3524.66 0.000077
HEAT PUMP HEATING MODE AIRLOOP F3 S2 0.229704 3540.44 0.000077
HEAT PUMP HEATING MODE AIRLOOP F4 SW 0.326274 4885.85 0.000107
HEAT PUMP HEATING MODE AIRLOOP F4 NW 0.255260 3829.31 0.000084
HEAT PUMP HEATING MODE AIRLOOP F4 SE 0.299576 4527.09 0.000099
HEAT PUMP HEATING MODE AIRLOOP F4 NE 0.185258 2812.66 0.000061
HEAT PUMP HEATING MODE AIRLOOP F4 N1 0.123609 1918.03 0.000042
HEAT PUMP HEATING MODE AIRLOOP F4 N2 0.121510 1888.04 0.000041
HEAT PUMP HEATING MODE AIRLOOP F4 S1 0.230553 3554.33 0.000078
HEAT PUMP HEATING MODE AIRLOOP F4 S2 0.231499 3567.55 0.000078
HEAT PUMP HEATING MODE AIRLOOP M SW 0.330052 4941.44 0.000108
HEAT PUMP HEATING MODE AIRLOOP M NW 0.258978 3892.61 0.000085
HEAT PUMP HEATING MODE AIRLOOP M SE 0.303240 4581.05 0.000100
HEAT PUMP HEATING MODE AIRLOOP M NE 0.188225 2856.48 0.000062
HEAT PUMP HEATING MODE AIRLOOP M N1 0.126887 1965.64 0.000043
HEAT PUMP HEATING MODE AIRLOOP M N2 0.124786 1935.64 0.000042
HEAT PUMP HEATING MODE AIRLOOP M S1 0.234010 3604.33 0.000079
HEAT PUMP HEATING MODE AIRLOOP M S2 0.234925 3617.14 0.000079
HEAT PUMP HEATING MODE AIRLOOP F6 SW 0.327971 4914.69 0.000107
HEAT PUMP HEATING MODE AIRLOOP F6 NW 0.256787 3863.98 0.000084
HEAT PUMP HEATING MODE AIRLOOP F6 SE 0.301298 4556.18 0.000100
HEAT PUMP HEATING MODE AIRLOOP F6 NE 0.185565 2821.07 0.000062
HEAT PUMP HEATING MODE AIRLOOP F6 N1 0.124669 1935.01 0.000042
HEAT PUMP HEATING MODE AIRLOOP F6 N2 0.122581 1905.17 0.000042
HEAT PUMP HEATING MODE AIRLOOP F6 S1 0.231712 3573.54 0.000078
HEAT PUMP HEATING MODE AIRLOOP F6 S2 0.232623 3586.28 0.000078
HEAT PUMP HEATING MODE AIRLOOP F7 SW 0.327830 4914.77 0.000107
HEAT PUMP HEATING MODE AIRLOOP F7 NW 0.256568 3862.75 0.000084
HEAT PUMP HEATING MODE AIRLOOP F7 SE 0.301272 4557.80 0.000100
HEAT PUMP HEATING MODE AIRLOOP F7 NE 0.184887 2813.19 0.000061
HEAT PUMP HEATING MODE AIRLOOP F7 N1 0.124316 1930.76 0.000042
HEAT PUMP HEATING MODE AIRLOOP F7 N2 0.122271 1913.34 0.000042
HEAT PUMP HEATING MODE AIRLOOP F7 S1 0.231349 3569.66 0.000078
HEAT PUMP HEATING MODE AIRLOOP F7 S2 0.232256 3582.35 0.000078
HEAT PUMP HEATING MODE AIRLOOP F8 SW 0.328639 4927.92 0.000108
HEAT PUMP HEATING MODE AIRLOOP F8 NW 0.257361 3875.52 0.000085
HEAT PUMP HEATING MODE AIRLOOP F8 SE 0.302165 4572.10 0.000100
HEAT PUMP HEATING MODE AIRLOOP F8 NE 0.185199 2819.01 0.000062
HEAT PUMP HEATING MODE AIRLOOP F8 N1 0.125006 1941.26 0.000042
HEAT PUMP HEATING MODE AIRLOOP F8 N2 0.123023 1924.71 0.000042
HEAT PUMP HEATING MODE AIRLOOP F8 S1 0.231961 3579.31 0.000078
HEAT PUMP HEATING MODE AIRLOOP F8 S2 0.232869 3592.01 0.000078
HEAT PUMP HEATING MODE AIRLOOP F9 SW 0.336210 5035.56 0.000110
HEAT PUMP HEATING MODE AIRLOOP F9 NW 0.265354 3989.25 0.000087
HEAT PUMP HEATING MODE AIRLOOP F9 SE 0.308412 4666.71 0.000102
HEAT PUMP HEATING MODE AIRLOOP F9 NE 0.189087 2992.31 0.000065
HEAT PUMP HEATING MODE AIRLOOP F9 N1 0.131998 2041.36 0.000045
HEAT PUMP HEATING MODE AIRLOOP F9 N2 0.130000 2024.47 0.000044
HEAT PUMP HEATING MODE AIRLOOP F9 S1 0.237087 3652.14 0.000080
HEAT PUMP HEATING MODE AIRLOOP F9 S2 0.238110 3666.45 0.000080
HEAT PUMP HEATING MODE AIRLOOP T SW 0.411393 6102.07 0.000133
HEAT PUMP HEATING MODE AIRLOOP T NW 0.327253 4880.66 0.000107
HEAT PUMP HEATING MODE AIRLOOP T SE 0.375254 5597.95 0.000122
HEAT PUMP HEATING MODE AIRLOOP T NE 0.242352 3742.16 0.000082
HEAT PUMP HEATING MODE AIRLOOP T N1 0.183666 2896.99 0.000063
HEAT PUMP HEATING MODE AIRLOOP T N2 0.183462 2900.88 0.000063
HEAT PUMP HEATING MODE AIRLOOP T S1 0.314125 4725.45 0.000103
HEAT PUMP HEATING MODE AIRLOOP T S2 0.315091 4738.94 0.000104


Coil:Heating:Electric

Nominal Capacity [W]
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW 2633.20
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW 2633.31
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE 3380.53
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE 2633.31
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 2008.22
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 2008.22
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 2004.40
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 2010.69
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW 2528.11
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW 2523.45
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE 2546.88
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE 2523.45
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 1755.15
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 1755.15
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 1762.58
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 1763.83
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW 2515.86
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW 2512.54
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE 2517.97
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE 2512.54
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 1712.12
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 1712.12
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 1716.20
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 1716.40
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW 2554.64
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW 2552.57
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE 2554.87
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE 2552.57
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 1725.84
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 1725.84
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 1728.44
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 1728.47
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW 2574.82
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW 2572.63
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE 2574.84
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE 2572.63
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 1726.94
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 1726.94
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 1729.62
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 1729.63
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW 2653.56
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW 2652.81
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE 2653.56
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE 2652.81
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 1786.44
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 1786.44
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 1787.61
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 1787.61
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW 2706.80
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW 2706.44
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE 2706.80
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE 2706.44
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 1824.23
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 1824.23
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 1825.03
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 1825.03
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW 2764.07
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW 2763.83
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE 2764.07
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE 2763.83
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 1867.67
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 1867.67
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 1868.32
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 1868.32
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW 2934.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW 2932.49
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE 2934.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE 2932.49
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 2016.33
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 2016.33
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 2018.46
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 2018.46
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW 3525.16
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW 3529.64
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE 3525.16
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE 3529.64
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 2650.04
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 2650.04
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 2642.57
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 2642.57


PlantLoop

Maximum Loop Flow Rate [m3/s] Plant Loop Volume [m3]
SHWSYS1 0.000289 0.325214
SINGLE WATER PLANT LOOP 0.006021 6.77


Boiler:HotWater

Design Water Flow Rate [m3/s]
CENTRAL BOILER 0.006021


WaterHeater:Mixed

Use Side Design Flow Rate [m3/s]
SHWSYS1 WATER HEATER 0.000289


EvaporativeFluidCooler:SingleSpeed

Design Water Flow Rate [m3/s] Fan Power at Design Air Flow Rate [W] Design Air Flow Rate [m3/s] U-Factor Times Area Value at Design Air Flow Rate [W/C]
CENTRAL TOWER 0.006021 2906.80 7.70 8956.62


Pump:ConstantSpeed

Rated Flow Rate [m3/s] Rated Power Consumption [W]
SHWSYS1 PUMP 0.000289 36.93
PLANT CIRC PUMP 0.006021 1922.92



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:13

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW3 |
G WWALL SWA GWINDOW2 |
G NWALL NWA GWINDOW4 |
G WWALL NWA GWINDOW6 |
G SWALL SEA GWINDOW1 |
G EWALL SEA GWINDOW8 |
G NWALL NEA GWINDOW5 |
G EWALL NEA GWINDOW7 |
G NWALL N1A GWINDOW9 |
G NWALL N2A GWINDOW10 |
G SWALL S1A GWINDOW11 |
G SWALL S2A GWINDOW12 |
G WWALL C GWINDOW13 |
G EWALL C ENTRANCE DOOR |
F2 WWALL SWA F2WINDOW2 |
F2 SWALL SWA F2WINDOW3 |
F2 NWALL NWA F2WINDOW4 |
F2 WWALL NWA F2WINDOW6 |
F2 EWALL SEA F2WINDOW8 |
F2 SWALL SEA F2WINDOW1 |
F2 NWALL NEA F2WINDOW5 |
F2 EWALL NEA F2WINDOW7 |
F2 NWALL N1A F2WINDOW9 |
F2 NWALL N2A F2WINDOW10 |
F2 SWALL S1A F2WINDOW11 |
F2 SWALL S2A F2WINDOW12 |
F2 WWALL C F2WINDOW13 |
F2 EWALL C F2WINDOW14 |
F3 WWALL SWA F3WINDOW2 |
F3 SWALL SWA F3WINDOW3 |
F3 NWALL NWA F3WINDOW4 |
F3 WWALL NWA F3WINDOW6 |
F3 EWALL SEA F3WINDOW8 |
F3 SWALL SEA F3WINDOW1 |
F3 NWALL NEA F3WINDOW5 |
F3 EWALL NEA F3WINDOW7 |
F3 NWALL N1A F3WINDOW9 |
F3 NWALL N2A F3WINDOW10 |
F3 SWALL S1A F3WINDOW11 |
F3 SWALL S2A F3WINDOW12 |
F3 WWALL C F3WINDOW13 |
F3 EWALL C F3WINDOW14 |
F4 WWALL SWA F4WINDOW2 |
F4 SWALL SWA F4WINDOW3 |
F4 NWALL NWA F4WINDOW4 |
F4 WWALL NWA F4WINDOW6 |
F4 EWALL SEA F4WINDOW8 |
F4 SWALL SEA F4WINDOW1 |
F4 NWALL NEA F4WINDOW5 |
F4 EWALL NEA F4WINDOW7 |
F4 NWALL N1A F4WINDOW9 |
F4 NWALL N2A F4WINDOW10 |
F4 SWALL S1A F4WINDOW11 |
F4 SWALL S2A F4WINDOW12 |
F4 WWALL C F4WINDOW13 |
F4 EWALL C F4WINDOW14 |
M WWALL SWA MWINDOW2 |
M SWALL SWA MWINDOW3 |
M NWALL NWA MWINDOW4 |
M WWALL NWA MWINDOW6 |
M EWALL SEA MWINDOW8 |
M SWALL SEA MWINDOW1 |
M NWALL NEA MWINDOW5 |
M EWALL NEA MWINDOW7 |
M NWALL N1A MWINDOW9 |
M NWALL N2A MWINDOW10 |
M SWALL S1A MWINDOW11 |
M SWALL S2A MWINDOW12 |
M WWALL C MWINDOW13 |
M EWALL C MWINDOW14 |
F6 WWALL SWA F6WINDOW2 |
F6 SWALL SWA F6WINDOW3 |
F6 NWALL NWA F6WINDOW4 |
F6 WWALL NWA F6WINDOW6 |
F6 EWALL SEA F6WINDOW8 |
F6 SWALL SEA F6WINDOW1 |
F6 NWALL NEA F6WINDOW5 |
F6 EWALL NEA F6WINDOW7 |
F6 NWALL N1A F6WINDOW9 |
F6 NWALL N2A F6WINDOW10 |
F6 SWALL S1A F6WINDOW11 |
F6 SWALL S2A F6WINDOW12 |
F6 WWALL C F6WINDOW13 |
F6 EWALL C F6WINDOW14 |
F7 WWALL SWA F7WINDOW2 |
F7 SWALL SWA F7WINDOW3 |
F7 NWALL NWA F7WINDOW4 |
F7 WWALL NWA F7WINDOW6 |
F7 EWALL SEA F7WINDOW8 |
F7 SWALL SEA F7WINDOW1 |
F7 NWALL NEA F7WINDOW5 |
F7 EWALL NEA F7WINDOW7 |
F7 NWALL N1A F7WINDOW9 |
F7 NWALL N2A F7WINDOW10 |
F7 SWALL S1A F7WINDOW11 |
F7 SWALL S2A F7WINDOW12 |
F7 WWALL C F7WINDOW13 |
F7 EWALL C F7WINDOW14 |
F8 WWALL SWA F8WINDOW2 |
F8 SWALL SWA F8WINDOW3 |
F8 NWALL NWA F8WINDOW4 |
F8 WWALL NWA F8WINDOW6 |
F8 EWALL SEA F8WINDOW8 |
F8 SWALL SEA F8WINDOW1 |
F8 NWALL NEA F8WINDOW5 |
F8 EWALL NEA F8WINDOW7 |
F8 NWALL N1A F8WINDOW9 |
F8 NWALL N2A F8WINDOW10 |
F8 SWALL S1A F8WINDOW11 |
F8 SWALL S2A F8WINDOW12 |
F8 WWALL C F8WINDOW13 |
F8 EWALL C F8WINDOW14 |
F9 WWALL SWA F9WINDOW2 |
F9 SWALL SWA F9WINDOW3 |
F9 NWALL NWA F9WINDOW4 |
F9 WWALL NWA F9WINDOW6 |
F9 EWALL SEA F9WINDOW8 |
F9 SWALL SEA F9WINDOW1 |
F9 NWALL NEA F9WINDOW5 |
F9 EWALL NEA F9WINDOW7 |
F9 NWALL N1A F9WINDOW9 |
F9 NWALL N2A F9WINDOW10 |
F9 SWALL S1A F9WINDOW11 |
F9 SWALL S2A F9WINDOW12 |
F9 WWALL C F9WINDOW13 |
F9 EWALL C F9WINDOW14 |
T WWALL SWA TWINDOW2 |
T SWALL SWA TWINDOW3 |
T NWALL NWA TWINDOW4 |
T WWALL NWA TWINDOW6 |
T EWALL SEA TWINDOW8 |
T SWALL SEA TWINDOW1 |
T NWALL NEA TWINDOW5 |
T EWALL NEA TWINDOW7 |
T NWALL N1A TWINDOW9 |
T NWALL N2A TWINDOW10 |
T SWALL S1A TWINDOW11 |
T SWALL S2A TWINDOW12 |
T WWALL C TWINDOW13 |
T EWALL C TWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2015-09-09 19:12:13

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.86 4.90
February 21.95 5.21
March 22.41 8.41
April 22.61 10.40
May 23.08 13.39
June 23.98 17.41
July 24.18 20.12
August 24.26 19.46
September 24.14 16.66
October 22.82 11.27
November 21.93 8.49
December 21.80 4.55
     
Annual Sum or Average 22.92 11.73
Minimum of Months 21.80 4.55
Maximum of Months 24.26 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.90
February 21.73 5.21
March 21.89 8.41
April 22.20 10.40
May 22.73 13.39
June 23.86 17.41
July 24.14 20.12
August 24.18 19.46
September 23.86 16.66
October 22.16 11.27
November 21.73 8.49
December 21.71 4.55
     
Annual Sum or Average 22.66 11.73
Minimum of Months 21.70 4.55
Maximum of Months 24.18 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.06 4.90
February 22.19 5.21
March 22.82 8.41
April 22.99 10.40
May 23.48 13.39
June 24.24 17.41
July 24.34 20.12
August 24.38 19.46
September 24.28 16.66
October 23.19 11.27
November 22.39 8.49
December 22.01 4.55
     
Annual Sum or Average 23.20 11.73
Minimum of Months 22.01 4.55
Maximum of Months 24.38 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.90
February 21.71 5.21
March 21.83 8.41
April 22.09 10.40
May 22.57 13.39
June 23.72 17.41
July 24.12 20.12
August 24.14 19.46
September 23.76 16.66
October 22.05 11.27
November 21.71 8.49
December 21.70 4.55
     
Annual Sum or Average 22.60 11.73
Minimum of Months 21.70 4.55
Maximum of Months 24.14 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.90
February 21.71 5.21
March 21.78 8.41
April 22.00 10.40
May 22.42 13.39
June 23.65 17.41
July 24.05 20.12
August 24.08 19.46
September 23.69 16.66
October 22.02 11.27
November 21.71 8.49
December 21.70 4.55
     
Annual Sum or Average 22.55 11.73
Minimum of Months 21.70 4.55
Maximum of Months 24.08 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.90
February 21.70 5.21
March 21.78 8.41
April 22.00 10.40
May 22.41 13.39
June 23.64 17.41
July 24.05 20.12
August 24.07 19.46
September 23.67 16.66
October 22.02 11.27
November 21.71 8.49
December 21.70 4.55
     
Annual Sum or Average 22.54 11.73
Minimum of Months 21.70 4.55
Maximum of Months 24.07 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.88 4.90
February 21.95 5.21
March 22.43 8.41
April 22.56 10.40
May 22.95 13.39
June 23.92 17.41
July 24.14 20.12
August 24.24 19.46
September 24.15 16.66
October 22.92 11.27
November 22.01 8.49
December 21.82 4.55
     
Annual Sum or Average 22.92 11.73
Minimum of Months 21.82 4.55
Maximum of Months 24.24 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.90 4.90
February 21.97 5.21
March 22.49 8.41
April 22.61 10.40
May 23.02 13.39
June 23.96 17.41
July 24.16 20.12
August 24.26 19.46
September 24.17 16.66
October 22.97 11.27
November 22.05 8.49
December 21.84 4.55
     
Annual Sum or Average 22.95 11.73
Minimum of Months 21.84 4.55
Maximum of Months 24.26 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 16.91 4.90
February 17.11 5.21
March 18.62 8.41
April 19.52 10.40
May 20.96 13.39
June 23.38 17.41
July 24.57 20.12
August 24.30 19.46
September 23.20 16.66
October 19.96 11.27
November 18.16 8.49
December 16.71 4.55
     
Annual Sum or Average 20.30 11.73
Minimum of Months 16.71 4.55
Maximum of Months 24.57 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SW APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.00 4.90
February 22.14 5.21
March 23.16 8.41
April 23.32 10.40
May 23.94 13.39
June 24.26 17.41
July 24.31 20.12
August 24.35 19.46
September 24.32 16.66
October 23.55 11.27
November 22.26 8.49
December 21.92 4.55
     
Annual Sum or Average 23.30 11.73
Minimum of Months 21.92 4.55
Maximum of Months 24.35 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NW APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.72 4.90
February 21.77 5.21
March 22.30 8.41
April 22.73 10.40
May 23.60 13.39
June 24.19 17.41
July 24.29 20.12
August 24.32 19.46
September 24.15 16.66
October 22.61 11.27
November 21.80 8.49
December 21.72 4.55
     
Annual Sum or Average 22.94 11.73
Minimum of Months 21.72 4.55
Maximum of Months 24.32 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SE APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.04 4.90
February 22.18 5.21
March 23.27 8.41
April 23.39 10.40
May 24.01 13.39
June 24.29 17.41
July 24.34 20.12
August 24.37 19.46
September 24.34 16.66
October 23.65 11.27
November 22.39 8.49
December 21.96 4.55
     
Annual Sum or Average 23.36 11.73
Minimum of Months 21.96 4.55
Maximum of Months 24.37 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NE APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.90
February 21.73 5.21
March 22.15 8.41
April 22.55 10.40
May 23.39 13.39
June 24.11 17.41
July 24.29 20.12
August 24.32 19.46
September 24.09 16.66
October 22.42 11.27
November 21.74 8.49
December 21.71 4.55
     
Annual Sum or Average 22.86 11.73
Minimum of Months 21.70 4.55
Maximum of Months 24.32 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N1 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.73 5.21
March 22.13 8.41
April 22.51 10.40
May 23.33 13.39
June 24.07 17.41
July 24.24 20.12
August 24.28 19.46
September 24.04 16.66
October 22.48 11.27
November 21.80 8.49
December 21.71 4.55
     
Annual Sum or Average 22.84 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.28 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N2 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.73 5.21
March 22.11 8.41
April 22.49 10.40
May 23.31 13.39
June 24.06 17.41
July 24.24 20.12
August 24.28 19.46
September 24.03 16.66
October 22.46 11.27
November 21.79 8.49
December 21.71 4.55
     
Annual Sum or Average 22.83 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.28 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S1 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.13 4.90
February 22.23 5.21
March 23.32 8.41
April 23.39 10.40
May 23.93 13.39
June 24.22 17.41
July 24.28 20.12
August 24.34 19.46
September 24.31 16.66
October 23.74 11.27
November 22.51 8.49
December 22.01 4.55
     
Annual Sum or Average 23.37 11.73
Minimum of Months 22.01 4.55
Maximum of Months 24.34 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S2 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.14 4.90
February 22.24 5.21
March 23.34 8.41
April 23.41 10.40
May 23.94 13.39
June 24.22 17.41
July 24.28 20.12
August 24.34 19.46
September 24.32 16.66
October 23.76 11.27
November 22.54 8.49
December 22.02 4.55
     
Annual Sum or Average 23.39 11.73
Minimum of Months 22.02 4.55
Maximum of Months 24.34 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 CORRIDOR

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.82 4.90
February 21.89 5.21
March 23.25 8.41
April 23.66 10.40
May 24.70 13.39
June 25.74 17.41
July 26.13 20.12
August 26.08 19.46
September 25.69 16.66
October 23.86 11.27
November 22.32 8.49
December 21.58 4.55
     
Annual Sum or Average 23.90 11.73
Minimum of Months 21.58 4.55
Maximum of Months 26.13 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SW APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.04 4.90
February 22.18 5.21
March 23.30 8.41
April 23.43 10.40
May 24.05 13.39
June 24.26 17.41
July 24.30 20.12
August 24.35 19.46
September 24.32 16.66
October 23.69 11.27
November 22.33 8.49
December 21.94 4.55
     
Annual Sum or Average 23.36 11.73
Minimum of Months 21.94 4.55
Maximum of Months 24.35 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NW APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.72 4.90
February 21.77 5.21
March 22.46 8.41
April 22.86 10.40
May 23.77 13.39
June 24.20 17.41
July 24.29 20.12
August 24.33 19.46
September 24.18 16.66
October 22.74 11.27
November 21.82 8.49
December 21.72 4.55
     
Annual Sum or Average 23.00 11.73
Minimum of Months 21.72 4.55
Maximum of Months 24.33 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SE APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.04 4.90
February 22.14 5.21
March 23.28 8.41
April 23.36 10.40
May 24.02 13.39
June 24.26 17.41
July 24.32 20.12
August 24.37 19.46
September 24.32 16.66
October 23.66 11.27
November 22.32 8.49
December 21.94 4.55
     
Annual Sum or Average 23.34 11.73
Minimum of Months 21.94 4.55
Maximum of Months 24.37 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NE APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.90
February 21.74 5.21
March 22.30 8.41
April 22.69 10.40
May 23.58 13.39
June 24.13 17.41
July 24.30 20.12
August 24.33 19.46
September 24.12 16.66
October 22.54 11.27
November 21.76 8.49
December 21.71 4.55
     
Annual Sum or Average 22.91 11.73
Minimum of Months 21.70 4.55
Maximum of Months 24.33 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N1 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.74 5.21
March 22.33 8.41
April 22.71 10.40
May 23.61 13.39
June 24.12 17.41
July 24.25 20.12
August 24.29 19.46
September 24.09 16.66
October 22.66 11.27
November 21.84 8.49
December 21.72 4.55
     
Annual Sum or Average 22.93 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.29 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N2 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.74 5.21
March 22.31 8.41
April 22.69 10.40
May 23.59 13.39
June 24.12 17.41
July 24.26 20.12
August 24.29 19.46
September 24.08 16.66
October 22.64 11.27
November 21.83 8.49
December 21.72 4.55
     
Annual Sum or Average 22.92 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.29 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S1 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.22 4.90
February 22.31 5.21
March 23.54 8.41
April 23.58 10.40
May 24.09 13.39
June 24.24 17.41
July 24.28 20.12
August 24.34 19.46
September 24.32 16.66
October 23.92 11.27
November 22.68 8.49
December 22.07 4.55
     
Annual Sum or Average 23.47 11.73
Minimum of Months 22.07 4.55
Maximum of Months 24.34 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S2 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.23 4.90
February 22.31 5.21
March 23.55 8.41
April 23.58 10.40
May 24.09 13.39
June 24.24 17.41
July 24.28 20.12
August 24.34 19.46
September 24.32 16.66
October 23.92 11.27
November 22.69 8.49
December 22.07 4.55
     
Annual Sum or Average 23.47 11.73
Minimum of Months 22.07 4.55
Maximum of Months 24.34 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 CORRIDOR

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.28 4.90
February 22.31 5.21
March 23.82 8.41
April 24.18 10.40
May 25.24 13.39
June 25.98 17.41
July 26.28 20.12
August 26.25 19.46
September 25.93 16.66
October 24.35 11.27
November 22.73 8.49
December 22.00 4.55
     
Annual Sum or Average 24.29 11.73
Minimum of Months 22.00 4.55
Maximum of Months 26.28 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SW APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.05 4.90
February 22.17 5.21
March 23.32 8.41
April 23.43 10.40
May 24.06 13.39
June 24.26 17.41
July 24.30 20.12
August 24.35 19.46
September 24.32 16.66
October 23.74 11.27
November 22.34 8.49
December 21.95 4.55
     
Annual Sum or Average 23.36 11.73
Minimum of Months 21.95 4.55
Maximum of Months 24.35 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NW APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.72 4.90
February 21.77 5.21
March 22.53 8.41
April 22.87 10.40
May 23.81 13.39
June 24.20 17.41
July 24.28 20.12
August 24.33 19.46
September 24.18 16.66
October 22.79 11.27
November 21.83 8.49
December 21.72 4.55
     
Annual Sum or Average 23.01 11.73
Minimum of Months 21.72 4.55
Maximum of Months 24.33 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SE APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.04 4.90
February 22.12 5.21
March 23.27 8.41
April 23.33 10.40
May 24.01 13.39
June 24.25 17.41
July 24.31 20.12
August 24.36 19.46
September 24.31 16.66
October 23.68 11.27
November 22.29 8.49
December 21.93 4.55
     
Annual Sum or Average 23.33 11.73
Minimum of Months 21.93 4.55
Maximum of Months 24.36 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NE APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.74 5.21
March 22.36 8.41
April 22.71 10.40
May 23.62 13.39
June 24.13 17.41
July 24.29 20.12
August 24.33 19.46
September 24.12 16.66
October 22.58 11.27
November 21.76 8.49
December 21.71 4.55
     
Annual Sum or Average 22.93 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.33 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N1 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.75 5.21
March 22.43 8.41
April 22.76 10.40
May 23.71 13.39
June 24.14 17.41
July 24.25 20.12
August 24.29 19.46
September 24.10 16.66
October 22.75 11.27
November 21.86 8.49
December 21.72 4.55
     
Annual Sum or Average 22.96 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.29 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N2 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.74 5.21
March 22.41 8.41
April 22.74 10.40
May 23.68 13.39
June 24.13 17.41
July 24.25 20.12
August 24.29 19.46
September 24.09 16.66
October 22.72 11.27
November 21.85 8.49
December 21.72 4.55
     
Annual Sum or Average 22.95 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.29 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S1 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.25 4.90
February 22.32 5.21
March 23.59 8.41
April 23.61 10.40
May 24.13 13.39
June 24.24 17.41
July 24.27 20.12
August 24.34 19.46
September 24.32 16.66
October 23.99 11.27
November 22.72 8.49
December 22.08 4.55
     
Annual Sum or Average 23.50 11.73
Minimum of Months 22.08 4.55
Maximum of Months 24.34 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S2 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.25 4.90
February 22.32 5.21
March 23.59 8.41
April 23.60 10.40
May 24.13 13.39
June 24.24 17.41
July 24.27 20.12
August 24.34 19.46
September 24.32 16.66
October 23.99 11.27
November 22.72 8.49
December 22.08 4.55
     
Annual Sum or Average 23.49 11.73
Minimum of Months 22.08 4.55
Maximum of Months 24.34 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 CORRIDOR

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.42 4.90
February 22.44 5.21
March 24.02 8.41
April 24.34 10.40
May 25.42 13.39
June 26.08 17.41
July 26.36 20.12
August 26.34 19.46
September 26.03 16.66
October 24.53 11.27
November 22.87 8.49
December 22.12 4.55
     
Annual Sum or Average 24.43 11.73
Minimum of Months 22.12 4.55
Maximum of Months 26.36 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.05 4.90
February 22.16 5.21
March 23.31 8.41
April 23.40 10.40
May 24.04 13.39
June 24.25 17.41
July 24.29 20.12
August 24.35 19.46
September 24.32 16.66
October 23.74 11.27
November 22.33 8.49
December 21.95 4.55
     
Annual Sum or Average 23.36 11.73
Minimum of Months 21.95 4.55
Maximum of Months 24.35 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.72 4.90
February 21.77 5.21
March 22.56 8.41
April 22.86 10.40
May 23.79 13.39
June 24.19 17.41
July 24.27 20.12
August 24.32 19.46
September 24.18 16.66
October 22.81 11.27
November 21.83 8.49
December 21.72 4.55
     
Annual Sum or Average 23.01 11.73
Minimum of Months 21.72 4.55
Maximum of Months 24.32 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.04 4.90
February 22.11 5.21
March 23.26 8.41
April 23.30 10.40
May 23.99 13.39
June 24.23 17.41
July 24.30 20.12
August 24.36 19.46
September 24.31 16.66
October 23.68 11.27
November 22.28 8.49
December 21.93 4.55
     
Annual Sum or Average 23.32 11.73
Minimum of Months 21.93 4.55
Maximum of Months 24.36 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.74 5.21
March 22.39 8.41
April 22.70 10.40
May 23.61 13.39
June 24.12 17.41
July 24.28 20.12
August 24.32 19.46
September 24.12 16.66
October 22.60 11.27
November 21.76 8.49
December 21.71 4.55
     
Annual Sum or Average 22.93 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.32 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.72 4.90
February 21.75 5.21
March 22.48 8.41
April 22.78 10.40
May 23.72 13.39
June 24.13 17.41
July 24.24 20.12
August 24.29 19.46
September 24.11 16.66
October 22.79 11.27
November 21.87 8.49
December 21.72 4.55
     
Annual Sum or Average 22.97 11.73
Minimum of Months 21.72 4.55
Maximum of Months 24.29 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.75 5.21
March 22.46 8.41
April 22.76 10.40
May 23.69 13.39
June 24.12 17.41
July 24.24 20.12
August 24.29 19.46
September 24.10 16.66
October 22.76 11.27
November 21.86 8.49
December 21.72 4.55
     
Annual Sum or Average 22.96 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.29 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.26 4.90
February 22.32 5.21
March 23.59 8.41
April 23.60 10.40
May 24.13 13.39
June 24.23 17.41
July 24.27 20.12
August 24.34 19.46
September 24.32 16.66
October 24.00 11.27
November 22.72 8.49
December 22.09 4.55
     
Annual Sum or Average 23.50 11.73
Minimum of Months 22.09 4.55
Maximum of Months 24.34 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.26 4.90
February 22.31 5.21
March 23.59 8.41
April 23.59 10.40
May 24.12 13.39
June 24.23 17.41
July 24.27 20.12
August 24.34 19.46
September 24.32 16.66
October 24.00 11.27
November 22.72 8.49
December 22.09 4.55
     
Annual Sum or Average 23.49 11.73
Minimum of Months 22.09 4.55
Maximum of Months 24.34 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.02 4.90
February 23.00 5.21
March 24.60 8.41
April 24.89 10.40
May 25.97 13.39
June 26.61 17.41
July 26.89 20.12
August 26.88 19.46
September 26.58 16.66
October 25.11 11.27
November 23.45 8.49
December 22.71 4.55
     
Annual Sum or Average 24.99 11.73
Minimum of Months 22.71 4.55
Maximum of Months 26.89 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SW APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.02 4.90
February 22.13 5.21
March 23.24 8.41
April 23.30 10.40
May 23.97 13.39
June 24.22 17.41
July 24.27 20.12
August 24.34 19.46
September 24.30 16.66
October 23.66 11.27
November 22.25 8.49
December 21.93 4.55
     
Annual Sum or Average 23.31 11.73
Minimum of Months 21.93 4.55
Maximum of Months 24.34 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NW APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.72 4.90
February 21.76 5.21
March 22.48 8.41
April 22.77 10.40
May 23.69 13.39
June 24.14 17.41
July 24.24 20.12
August 24.31 19.46
September 24.14 16.66
October 22.72 11.27
November 21.80 8.49
December 21.72 4.55
     
Annual Sum or Average 22.96 11.73
Minimum of Months 21.72 4.55
Maximum of Months 24.31 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SE APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.01 4.90
February 22.08 5.21
March 23.19 8.41
April 23.21 10.40
May 23.90 13.39
June 24.20 17.41
July 24.28 20.12
August 24.35 19.46
September 24.29 16.66
October 23.60 11.27
November 22.20 8.49
December 21.91 4.55
     
Annual Sum or Average 23.27 11.73
Minimum of Months 21.91 4.55
Maximum of Months 24.35 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NE APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.90
February 21.73 5.21
March 22.32 8.41
April 22.61 10.40
May 23.50 13.39
June 24.06 17.41
July 24.26 20.12
August 24.31 19.46
September 24.07 16.66
October 22.51 11.27
November 21.74 8.49
December 21.71 4.55
     
Annual Sum or Average 22.88 11.73
Minimum of Months 21.70 4.55
Maximum of Months 24.31 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N1 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.74 5.21
March 22.40 8.41
April 22.69 10.40
May 23.61 13.39
June 24.07 17.41
July 24.21 20.12
August 24.28 19.46
September 24.06 16.66
October 22.69 11.27
November 21.83 8.49
December 21.72 4.55
     
Annual Sum or Average 22.92 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.28 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N2 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.74 5.21
March 22.38 8.41
April 22.67 10.40
May 23.58 13.39
June 24.07 17.41
July 24.22 20.12
August 24.28 19.46
September 24.05 16.66
October 22.66 11.27
November 21.82 8.49
December 21.72 4.55
     
Annual Sum or Average 22.91 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.28 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S1 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.21 4.90
February 22.26 5.21
March 23.52 8.41
April 23.50 10.40
May 24.06 13.39
June 24.20 17.41
July 24.25 20.12
August 24.33 19.46
September 24.31 16.66
October 23.94 11.27
November 22.62 8.49
December 22.05 4.55
     
Annual Sum or Average 23.44 11.73
Minimum of Months 22.05 4.55
Maximum of Months 24.33 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S2 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.21 4.90
February 22.26 5.21
March 23.51 8.41
April 23.49 10.40
May 24.06 13.39
June 24.20 17.41
July 24.25 20.12
August 24.33 19.46
September 24.31 16.66
October 23.94 11.27
November 22.61 8.49
December 22.05 4.55
     
Annual Sum or Average 23.44 11.73
Minimum of Months 22.05 4.55
Maximum of Months 24.33 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 CORRIDOR

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.39 4.90
February 22.36 5.21
March 23.97 8.41
April 24.23 10.40
May 25.33 13.39
June 26.01 17.41
July 26.31 20.12
August 26.31 19.46
September 25.99 16.66
October 24.48 11.27
November 22.79 8.49
December 22.08 4.55
     
Annual Sum or Average 24.37 11.73
Minimum of Months 22.08 4.55
Maximum of Months 26.31 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SW APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.00 4.90
February 22.10 5.21
March 23.18 8.41
April 23.23 10.40
May 23.91 13.39
June 24.19 17.41
July 24.25 20.12
August 24.33 19.46
September 24.29 16.66
October 23.60 11.27
November 22.19 8.49
December 21.91 4.55
     
Annual Sum or Average 23.27 11.73
Minimum of Months 21.91 4.55
Maximum of Months 24.33 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NW APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.75 5.21
March 22.43 8.41
April 22.70 10.40
May 23.61 13.39
June 24.11 17.41
July 24.23 20.12
August 24.30 19.46
September 24.11 16.66
October 22.65 11.27
November 21.78 8.49
December 21.71 4.55
     
Annual Sum or Average 22.93 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.30 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SE APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.99 4.90
February 22.05 5.21
March 23.13 8.41
April 23.14 10.40
May 23.84 13.39
June 24.17 17.41
July 24.26 20.12
August 24.35 19.46
September 24.28 16.66
October 23.53 11.27
November 22.14 8.49
December 21.89 4.55
     
Annual Sum or Average 23.24 11.73
Minimum of Months 21.89 4.55
Maximum of Months 24.35 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NE APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.90
February 21.72 5.21
March 22.27 8.41
April 22.54 10.40
May 23.42 13.39
June 24.01 17.41
July 24.24 20.12
August 24.29 19.46
September 24.03 16.66
October 22.45 11.27
November 21.73 8.49
December 21.71 4.55
     
Annual Sum or Average 22.85 11.73
Minimum of Months 21.70 4.55
Maximum of Months 24.29 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N1 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.73 5.21
March 22.34 8.41
April 22.61 10.40
May 23.52 13.39
June 24.03 17.41
July 24.19 20.12
August 24.26 19.46
September 24.02 16.66
October 22.61 11.27
November 21.80 8.49
December 21.71 4.55
     
Annual Sum or Average 22.89 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.26 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N2 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.73 5.21
March 22.32 8.41
April 22.59 10.40
May 23.49 13.39
June 24.02 17.41
July 24.19 20.12
August 24.26 19.46
September 24.02 16.66
October 22.59 11.27
November 21.80 8.49
December 21.71 4.55
     
Annual Sum or Average 22.88 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.26 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S1 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.18 4.90
February 22.22 5.21
March 23.45 8.41
April 23.41 10.40
May 24.01 13.39
June 24.18 17.41
July 24.23 20.12
August 24.32 19.46
September 24.29 16.66
October 23.88 11.27
November 22.53 8.49
December 22.03 4.55
     
Annual Sum or Average 23.40 11.73
Minimum of Months 22.03 4.55
Maximum of Months 24.32 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S2 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.18 4.90
February 22.22 5.21
March 23.45 8.41
April 23.40 10.40
May 24.00 13.39
June 24.18 17.41
July 24.23 20.12
August 24.32 19.46
September 24.29 16.66
October 23.88 11.27
November 22.53 8.49
December 22.03 4.55
     
Annual Sum or Average 23.40 11.73
Minimum of Months 22.03 4.55
Maximum of Months 24.32 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 CORRIDOR

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.25 4.90
February 22.21 5.21
March 23.81 8.41
April 24.05 10.40
May 25.17 13.39
June 25.89 17.41
July 26.21 20.12
August 26.22 19.46
September 25.88 16.66
October 24.31 11.27
November 22.63 8.49
December 21.94 4.55
     
Annual Sum or Average 24.23 11.73
Minimum of Months 21.94 4.55
Maximum of Months 26.22 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SW APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.98 4.90
February 22.08 5.21
March 23.13 8.41
April 23.16 10.40
May 23.86 13.39
June 24.17 17.41
July 24.24 20.12
August 24.33 19.46
September 24.27 16.66
October 23.53 11.27
November 22.14 8.49
December 21.90 4.55
     
Annual Sum or Average 23.24 11.73
Minimum of Months 21.90 4.55
Maximum of Months 24.33 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NW APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.74 5.21
March 22.37 8.41
April 22.64 10.40
May 23.54 13.39
June 24.07 17.41
July 24.21 20.12
August 24.29 19.46
September 24.08 16.66
October 22.58 11.27
November 21.77 8.49
December 21.71 4.55
     
Annual Sum or Average 22.90 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.29 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SE APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.97 4.90
February 22.03 5.21
March 23.08 8.41
April 23.08 10.40
May 23.78 13.39
June 24.14 17.41
July 24.25 20.12
August 24.34 19.46
September 24.26 16.66
October 23.46 11.27
November 22.09 8.49
December 21.88 4.55
     
Annual Sum or Average 23.20 11.73
Minimum of Months 21.88 4.55
Maximum of Months 24.34 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NE APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.90
February 21.72 5.21
March 22.23 8.41
April 22.48 10.40
May 23.34 13.39
June 23.97 17.41
July 24.22 20.12
August 24.28 19.46
September 24.00 16.66
October 22.39 11.27
November 21.72 8.49
December 21.71 4.55
     
Annual Sum or Average 22.82 11.73
Minimum of Months 21.70 4.55
Maximum of Months 24.28 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N1 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.73 5.21
March 22.29 8.41
April 22.55 10.40
May 23.44 13.39
June 24.00 17.41
July 24.17 20.12
August 24.25 19.46
September 23.99 16.66
October 22.54 11.27
November 21.78 8.49
December 21.71 4.55
     
Annual Sum or Average 22.85 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.25 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N2 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.73 5.21
March 22.27 8.41
April 22.53 10.40
May 23.42 13.39
June 23.98 17.41
July 24.17 20.12
August 24.25 19.46
September 23.98 16.66
October 22.52 11.27
November 21.78 8.49
December 21.71 4.55
     
Annual Sum or Average 22.84 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.25 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S1 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.15 4.90
February 22.19 5.21
March 23.39 8.41
April 23.33 10.40
May 23.95 13.39
June 24.16 17.41
July 24.22 20.12
August 24.32 19.46
September 24.28 16.66
October 23.82 11.27
November 22.45 8.49
December 22.00 4.55
     
Annual Sum or Average 23.36 11.73
Minimum of Months 22.00 4.55
Maximum of Months 24.32 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S2 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.15 4.90
February 22.18 5.21
March 23.38 8.41
April 23.32 10.40
May 23.94 13.39
June 24.16 17.41
July 24.22 20.12
August 24.32 19.46
September 24.28 16.66
October 23.81 11.27
November 22.45 8.49
December 22.00 4.55
     
Annual Sum or Average 23.36 11.73
Minimum of Months 22.00 4.55
Maximum of Months 24.32 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 CORRIDOR

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.17 4.90
February 22.13 5.21
March 23.70 8.41
April 23.94 10.40
May 25.07 13.39
June 25.84 17.41
July 26.18 20.12
August 26.20 19.46
September 25.82 16.66
October 24.20 11.27
November 22.54 8.49
December 21.86 4.55
     
Annual Sum or Average 24.15 11.73
Minimum of Months 21.86 4.55
Maximum of Months 26.20 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SW APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.95 4.90
February 22.05 5.21
March 23.04 8.41
April 23.09 10.40
May 23.79 13.39
June 24.14 17.41
July 24.23 20.12
August 24.32 19.46
September 24.25 16.66
October 23.40 11.27
November 22.08 8.49
December 21.88 4.55
     
Annual Sum or Average 23.19 11.73
Minimum of Months 21.88 4.55
Maximum of Months 24.32 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NW APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.74 5.21
March 22.31 8.41
April 22.58 10.40
May 23.47 13.39
June 24.03 17.41
July 24.19 20.12
August 24.28 19.46
September 24.03 16.66
October 22.50 11.27
November 21.76 8.49
December 21.71 4.55
     
Annual Sum or Average 22.87 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.28 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SE APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.95 4.90
February 22.01 5.21
March 22.99 8.41
April 23.01 10.40
May 23.71 13.39
June 24.11 17.41
July 24.23 20.12
August 24.33 19.46
September 24.24 16.66
October 23.33 11.27
November 22.04 8.49
December 21.87 4.55
     
Annual Sum or Average 23.16 11.73
Minimum of Months 21.87 4.55
Maximum of Months 24.33 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NE APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.90
February 21.71 5.21
March 22.18 8.41
April 22.43 10.40
May 23.27 13.39
June 23.92 17.41
July 24.19 20.12
August 24.26 19.46
September 23.94 16.66
October 22.32 11.27
November 21.72 8.49
December 21.70 4.55
     
Annual Sum or Average 22.79 11.73
Minimum of Months 21.70 4.55
Maximum of Months 24.26 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N1 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.72 5.21
March 22.23 8.41
April 22.49 10.40
May 23.37 13.39
June 23.96 17.41
July 24.16 20.12
August 24.24 19.46
September 23.95 16.66
October 22.45 11.27
November 21.76 8.49
December 21.71 4.55
     
Annual Sum or Average 22.82 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.24 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N2 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.72 5.21
March 22.21 8.41
April 22.48 10.40
May 23.34 13.39
June 23.95 17.41
July 24.16 20.12
August 24.24 19.46
September 23.94 16.66
October 22.43 11.27
November 21.76 8.49
December 21.71 4.55
     
Annual Sum or Average 22.81 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.24 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S1 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.09 4.90
February 22.14 5.21
March 23.27 8.41
April 23.24 10.40
May 23.88 13.39
June 24.13 17.41
July 24.20 20.12
August 24.31 19.46
September 24.27 16.66
October 23.68 11.27
November 22.34 8.49
December 21.97 4.55
     
Annual Sum or Average 23.30 11.73
Minimum of Months 21.97 4.55
Maximum of Months 24.31 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S2 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.09 4.90
February 22.14 5.21
March 23.27 8.41
April 23.23 10.40
May 23.87 13.39
June 24.13 17.41
July 24.20 20.12
August 24.31 19.46
September 24.27 16.66
October 23.68 11.27
November 22.34 8.49
December 21.97 4.55
     
Annual Sum or Average 23.30 11.73
Minimum of Months 21.97 4.55
Maximum of Months 24.31 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 CORRIDOR

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.01 4.90
February 21.99 5.21
March 23.55 8.41
April 23.83 10.40
May 24.98 13.39
June 25.83 17.41
July 26.21 20.12
August 26.21 19.46
September 25.77 16.66
October 24.03 11.27
November 22.39 8.49
December 21.72 4.55
     
Annual Sum or Average 24.05 11.73
Minimum of Months 21.72 4.55
Maximum of Months 26.21 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.93 4.90
February 22.03 5.21
March 22.77 8.41
April 22.91 10.40
May 23.49 13.39
June 23.94 17.41
July 24.12 20.12
August 24.22 19.46
September 24.03 16.66
October 23.01 11.27
November 22.06 8.49
December 21.88 4.55
     
Annual Sum or Average 23.04 11.73
Minimum of Months 21.88 4.55
Maximum of Months 24.22 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 4.90
February 21.77 5.21
March 22.28 8.41
April 22.53 10.40
May 23.22 13.39
June 23.79 17.41
July 24.05 20.12
August 24.10 19.46
September 23.70 16.66
October 22.40 11.27
November 21.78 8.49
December 21.72 4.55
     
Annual Sum or Average 22.76 11.73
Minimum of Months 21.72 4.55
Maximum of Months 24.10 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.93 4.90
February 22.01 5.21
March 22.74 8.41
April 22.86 10.40
May 23.43 13.39
June 23.90 17.41
July 24.12 20.12
August 24.22 19.46
September 24.00 16.66
October 22.96 11.27
November 22.03 8.49
December 21.87 4.55
     
Annual Sum or Average 23.01 11.73
Minimum of Months 21.87 4.55
Maximum of Months 24.22 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.73 5.21
March 22.18 8.41
April 22.41 10.40
May 23.08 13.39
June 23.67 17.41
July 24.03 20.12
August 24.06 19.46
September 23.60 16.66
October 22.25 11.27
November 21.73 8.49
December 21.71 4.55
     
Annual Sum or Average 22.68 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.06 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.74 5.21
March 22.19 8.41
April 22.45 10.40
May 23.15 13.39
June 23.75 17.41
July 24.01 20.12
August 24.06 19.46
September 23.64 16.66
October 22.32 11.27
November 21.76 8.49
December 21.72 4.55
     
Annual Sum or Average 22.71 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.06 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.73 5.21
March 22.18 8.41
April 22.44 10.40
May 23.14 13.39
June 23.74 17.41
July 24.01 20.12
August 24.06 19.46
September 23.63 16.66
October 22.30 11.27
November 21.76 8.49
December 21.72 4.55
     
Annual Sum or Average 22.71 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.06 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.00 4.90
February 22.09 5.21
March 22.95 8.41
April 23.05 10.40
May 23.61 13.39
June 24.00 17.41
July 24.12 20.12
August 24.24 19.46
September 24.10 16.66
October 23.23 11.27
November 22.22 8.49
December 21.94 4.55
     
Annual Sum or Average 23.14 11.73
Minimum of Months 21.94 4.55
Maximum of Months 24.24 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.00 4.90
February 22.09 5.21
March 22.94 8.41
April 23.05 10.40
May 23.60 13.39
June 23.99 17.41
July 24.12 20.12
August 24.24 19.46
September 24.10 16.66
October 23.23 11.27
November 22.22 8.49
December 21.94 4.55
     
Annual Sum or Average 23.13 11.73
Minimum of Months 21.94 4.55
Maximum of Months 24.24 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2015-09-09 19:12:13

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.00 4.90
February 22.06 5.21
March 23.65 8.41
April 24.15 10.40
May 25.37 13.39
June 26.36 17.41
July 26.89 20.12
August 26.80 19.46
September 26.13 16.66
October 24.09 11.27
November 22.50 8.49
December 21.72 4.55
     
Annual Sum or Average 24.32 11.73
Minimum of Months 21.72 4.55
Maximum of Months 26.89 20.12



Table of Contents

Report: COMPONENTS OF PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2015-09-09 19:12:13

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY {AT MAX/MIN} [W] HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W]
January 0.235133E+12 126492.141 10-JAN-17:15 11327.174 57142.088 21005.320 22698.518 0.000 10364.000 1959.845 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
February 0.218811E+12 135718.324 07-FEB-18:00 13120.457 57042.023 21005.320 30238.671 0.000 10364.000 1959.845 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
March 0.215029E+12 120298.190 20-MAR-18:30 14401.373 51749.961 21005.320 0.000 18552.749 10364.000 1959.845 503.918 0.000 0.000 0.000 0.000 0.000 0.000 0.000
April 0.205757E+12 148909.650 29-APR-16:15 11327.174 57042.023 21005.320 0.000 53415.972 0.000 1959.845 2171.674 0.000 0.000 0.000 0.000 0.000 0.000 0.000
May 0.214828E+12 155432.416 05-MAY-16:15 11327.174 57142.088 21005.320 0.000 59710.048 0.000 1959.845 2292.744 0.000 0.000 0.000 0.000 0.000 0.000 0.000
June 0.227634E+12 161304.406 25-JUN-17:15 13120.457 57042.023 21005.320 0.000 63995.978 0.000 1959.845 2192.973 0.000 0.000 0.000 0.000 0.000 0.000 0.000
July 0.260351E+12 165462.525 19-JUL-17:15 13120.457 57042.023 21005.320 0.000 67773.435 0.000 1959.845 2573.634 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 0.259016E+12 161152.537 31-AUG-16:30 11327.174 57142.088 21005.320 0.000 65477.740 0.000 1959.845 2245.212 0.000 0.000 0.000 0.000 0.000 0.000 0.000
September 0.233789E+12 162989.237 09-SEP-16:15 11327.174 57042.023 21005.320 0.000 67273.385 0.000 1959.845 2393.848 0.000 0.000 0.000 0.000 0.000 0.000 0.000
October 0.215019E+12 132763.638 01-OCT-16:15 11327.174 57042.023 21005.320 0.000 37905.591 0.000 1959.845 1536.043 0.000 0.000 0.000 0.000 0.000 0.000 0.000
November 0.213916E+12 121656.378 26-NOV-18:00 13120.457 57042.023 21005.320 16176.725 0.000 10364.000 1959.845 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
December 0.245739E+12 139683.963 20-DEC-17:00 11327.174 57142.088 21005.320 35890.377 0.000 10364.000 1959.845 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
                                     
Annual Sum or Average 0.274502E+13                     0.000 0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.205757E+12 120298.190   11327.174 51749.961 21005.320 0.000 0.000 0.000 1959.845 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.260351E+12 165462.525   14401.373 57142.088 21005.320 35890.377 67773.435 10364.000 1959.845 2573.634 0.000 0.000 0.000 0.000 0.000 0.000 0.000



Table of Contents

Report: COMPONENTS OF PEAK GAS DEMAND

For: Meter

Timestamp: 2015-09-09 19:12:13

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC [Invalid/Undefined] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT {AT MAX/MIN} [W] WATERSYSTEMS:GAS {AT MAX/MIN} [W] WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] HEATING:GAS {AT MAX/MIN} [W]
January 0.208621E+12 183360.365 03-JAN-07:30 0.000 0.000 0.000 183360.365 79193.909 79193.909 104166.457
February 0.220870E+12 254268.154 15-FEB-06:15 0.000 0.000 0.000 254268.154 67283.937 67283.937 186984.218
March 0.128199E+12 159478.822 03-MAR-06:15 0.000 0.000 0.000 159478.822 66369.610 66369.610 93109.212
April 0.114535E+12 140653.624 11-APR-05:30 0.000 0.000 0.000 140653.624 74423.600 74423.600 66230.024
May 0.978567E+11 96124.937 24-MAY-05:45 0.000 0.000 0.000 96124.937 74770.273 74770.273 21354.664
June 0.909604E+11 76787.293 01-JUN-06:00 0.000 0.000 0.000 76787.293 76787.293 76787.293 0.000
July 0.916330E+11 75785.195 01-JUL-06:00 0.000 0.000 0.000 75785.195 75785.195 75785.195 0.000
August 0.908674E+11 75272.210 29-AUG-06:00 0.000 0.000 0.000 75272.210 75272.210 75272.210 0.000
September 0.889742E+11 75910.364 29-SEP-06:00 0.000 0.000 0.000 75910.364 75910.364 75910.364 0.000
October 0.998397E+11 129290.659 31-OCT-09:15 0.000 0.000 0.000 129290.659 71031.342 71031.342 58259.317
November 0.147386E+12 155355.528 20-NOV-09:15 0.000 0.000 0.000 155355.528 74575.194 74575.194 80780.334
December 0.252825E+12 258365.998 20-DEC-07:00 0.000 0.000 0.000 258365.998 78981.475 78981.475 179384.523
                     
Annual Sum or Average 0.163257E+13     0.000 0.000 0.000        
Minimum of Months 0.889742E+11 75272.210   0.000 0.000 0.000 75272.210 66369.610 66369.610 0.000
Maximum of Months 0.252825E+12 258365.998   0.000 0.000 0.000 258365.998 79193.909 79193.909 186984.218