Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 19:10
Tabular Output Report in Format: HTML
Building: High-Rise Apartment
Environment: Houston Bush Intercontinental TX USA TMY3 WMO#=722430
Simulation Timestamp: 2015-09-09 19:11:57
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:57
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 4446.16 | 567.37 | 629.78 |
Net Site Energy | 4446.16 | 567.37 | 629.78 |
Total Source Energy | 11874.30 | 1515.26 | 1681.94 |
Net Source Energy | 11874.30 | 1515.26 | 1681.94 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 7836.48 |
Net Conditioned Building Area | 7059.89 |
Unconditioned Building Area | 776.58 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 49.16 | 140.95 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 924.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 296.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 162.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1137.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 659.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 73.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 46.83 | 0.00 | 0.00 | 0.00 | 0.00 | 2392.76 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 918.44 | 0.00 | 0.00 | 0.00 | 4778.51 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 3386.78 | 1059.39 | 0.00 | 0.00 | 0.00 | 7171.27 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Boiler | 0.00 | 140.95 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Other | 49.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 924.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 242.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 54.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 162.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 1137.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 659.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 73.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 46.83 | 0.00 | 0.00 | 0.00 | 0.00 | 2392.76 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 918.44 | 0.00 | 0.00 | 0.00 | 0.00 |
sub cat | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4778.51 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 65.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 248.43 | 150.06 | 0.00 | 0.00 | 0.00 | 1.02 |
Other | 161.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 479.72 | 150.06 | 0.00 | 0.00 | 0.00 | 1.02 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 58.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 223.81 | 135.19 | 0.00 | 0.00 | 0.00 | 0.92 |
Other | 145.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 432.18 | 135.19 | 0.00 | 0.00 | 0.00 | 0.92 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 3386.78 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 3386.78 | 100.00 |
Total On-Site and Utility Electric Sources | 3386.78 | 100.00 |
Total Electricity End Uses | 3386.78 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 7171.27 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 7171.27 | 100.00 |
Total Water End Uses | 7171.27 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 47.25 |
Time Setpoint Not Met During Occupied Cooling | 313.50 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 3681.50 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |COMPONENTS OF PEAK ELECTRICAL DEMAND
| Meter |COMPONENTS OF PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:57
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 19:10 |
RunPeriod | Houston Bush Intercontinental TX USA TMY3 WMO#=722430 |
Weather File | Houston Bush Intercontinental TX USA TMY3 WMO#=722430 |
Latitude [deg] | 30.00 |
Longitude [deg] | -95.4 |
Elevation [m] | 29.00 |
Time Zone | -6.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 3855.02 | 1411.96 | 515.55 | 1411.96 | 515.55 |
Window Opening Area [m2] | 1150.39 | 423.59 | 152.73 | 423.59 | 150.48 |
Window-Wall Ratio [%] | 29.84 | 30.00 | 29.62 | 30.00 | 29.19 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 3752.84 | 1411.96 | 464.46 | 1411.96 | 464.46 |
Window Opening Area [m2] | 1125.85 | 423.59 | 139.34 | 423.59 | 139.34 |
Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 29.5362 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 4.47 | 6.7128 | 0.0000 | |
F2 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F3 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F4 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
M SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 13.4255 | 0.0000 | |
F6 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F7 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F8 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F9 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
T SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 264.3872 | |
Total | 7836.48 | 23884.04 | 3855.02 | 1150.39 | 4.3335 | 39.48 | 8.6291 | |||
Conditioned Total | 7059.89 | 21517.16 | 3752.84 | 1125.85 | 3.9979 | 35.57 | 6.6700 | |||
Unconditioned Total | 776.58 | 2366.87 | 102.18 | 24.54 | 7.3840 | 26.4387 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:57
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 04-AUG-17:15 | 11-FEB-06:45 | - | - | - | 02-AUG-17:15 |
Heating | 0.00 | 205316.53 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 90227.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 13120.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 57042.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 20924.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 2453.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 3653.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 72689.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 189408.37 | 278005.55 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | Boiler | 0.00 | 205316.53 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 90227.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 10541.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 2579.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 57042.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 20924.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 2453.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 3653.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 72689.02 | 0.00 | 0.00 | 0.00 | 0.00 |
sub cat | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:57
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 155.68 | 152.78 | 0.00 | 0.00 | 0.00 |
Cooling | 2929.16 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 939.20 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 515.78 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 3601.91 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 2089.78 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 231.56 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 148.30 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 995.59 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 10725.93 | 1148.37 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 22.05 | 21.64 | 0.00 | 0.00 | 0.00 |
Cooling | 414.90 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 133.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 73.06 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 510.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 296.01 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 32.80 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 21.01 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 141.02 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1519.28 | 162.66 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 22.05 | 21.64 | 0.00 | 0.00 | 0.00 |
Cooling | 414.90 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 133.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 73.06 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 510.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 296.01 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 32.80 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 21.01 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 141.02 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1519.28 | 162.66 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:57
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | -1.60 | 0.00 | -1.60 | Wetbulb [C] | 2.80 | 0.00 |
HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 36.00 | 10.10 | 24.80 | Wetbulb [C] | 3.50 | 170.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:57
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 270.00 | 180.00 | |
F2 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F2 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F2 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F2 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F2 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F2 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F2 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F2 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F3 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F3 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F3 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F3 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F3 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F3 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F3 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F3 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F4 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F4 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F4 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F4 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F4 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F4 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F4 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F4 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
M WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F6 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F6 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F6 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F6 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F6 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F6 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F6 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F6 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F7 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F7 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F7 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F7 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F7 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F7 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F7 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F7 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F8 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F8 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F8 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F8 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F8 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F8 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F8 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F8 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
F9 WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F9 SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
F9 EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F9 SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
F9 NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
F9 SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
F9 WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
F9 EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.30 | 0.269 | 0.283 | 77.66 | 0.00 | 0.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
GWINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | G WWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_0.72_SHGC_0.25 | 3.36 | 0.00 | 0.00 | 3.36 | 3.36 | 4.600 | 0.293 | 0.130 | No | G EWALL C | 90.00 | 90.00 | E | ||
F2WINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F2 WWALL SWA | 270.00 | 90.00 | W | ||
F2WINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 SWALL SWA | 180.00 | 90.00 | S | ||
F2WINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 NWALL NWA | 0.00 | 90.00 | N | ||
F2WINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F2 WWALL NWA | 270.00 | 90.00 | W | ||
F2WINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F2 EWALL SEA | 90.00 | 90.00 | E | ||
F2WINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 SWALL SEA | 180.00 | 90.00 | S | ||
F2WINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 NWALL NEA | 0.00 | 90.00 | N | ||
F2WINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F2 EWALL NEA | 90.00 | 90.00 | E | ||
F2WINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 NWALL N1A | 0.00 | 90.00 | N | ||
F2WINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 NWALL N2A | 0.00 | 90.00 | N | ||
F2WINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 SWALL S1A | 180.00 | 90.00 | S | ||
F2WINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F2 SWALL S2A | 180.00 | 90.00 | S | ||
F2WINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F2 WWALL C | 270.00 | 90.00 | W | ||
F2WINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F2 EWALL C | 90.00 | 90.00 | E | ||
F3WINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F3 WWALL SWA | 270.00 | 90.00 | W | ||
F3WINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 SWALL SWA | 180.00 | 90.00 | S | ||
F3WINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 NWALL NWA | 0.00 | 90.00 | N | ||
F3WINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F3 WWALL NWA | 270.00 | 90.00 | W | ||
F3WINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F3 EWALL SEA | 90.00 | 90.00 | E | ||
F3WINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 SWALL SEA | 180.00 | 90.00 | S | ||
F3WINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 NWALL NEA | 0.00 | 90.00 | N | ||
F3WINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F3 EWALL NEA | 90.00 | 90.00 | E | ||
F3WINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 NWALL N1A | 0.00 | 90.00 | N | ||
F3WINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 NWALL N2A | 0.00 | 90.00 | N | ||
F3WINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 SWALL S1A | 180.00 | 90.00 | S | ||
F3WINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F3 SWALL S2A | 180.00 | 90.00 | S | ||
F3WINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F3 WWALL C | 270.00 | 90.00 | W | ||
F3WINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F3 EWALL C | 90.00 | 90.00 | E | ||
F4WINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F4 WWALL SWA | 270.00 | 90.00 | W | ||
F4WINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 SWALL SWA | 180.00 | 90.00 | S | ||
F4WINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 NWALL NWA | 0.00 | 90.00 | N | ||
F4WINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F4 WWALL NWA | 270.00 | 90.00 | W | ||
F4WINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F4 EWALL SEA | 90.00 | 90.00 | E | ||
F4WINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 SWALL SEA | 180.00 | 90.00 | S | ||
F4WINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 NWALL NEA | 0.00 | 90.00 | N | ||
F4WINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F4 EWALL NEA | 90.00 | 90.00 | E | ||
F4WINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 NWALL N1A | 0.00 | 90.00 | N | ||
F4WINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 NWALL N2A | 0.00 | 90.00 | N | ||
F4WINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 SWALL S1A | 180.00 | 90.00 | S | ||
F4WINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F4 SWALL S2A | 180.00 | 90.00 | S | ||
F4WINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F4 WWALL C | 270.00 | 90.00 | W | ||
F4WINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F4 EWALL C | 90.00 | 90.00 | E | ||
MWINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | M WWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | M EWALL C | 90.00 | 90.00 | E | ||
F6WINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F6 WWALL SWA | 270.00 | 90.00 | W | ||
F6WINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 SWALL SWA | 180.00 | 90.00 | S | ||
F6WINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 NWALL NWA | 0.00 | 90.00 | N | ||
F6WINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F6 WWALL NWA | 270.00 | 90.00 | W | ||
F6WINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F6 EWALL SEA | 90.00 | 90.00 | E | ||
F6WINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 SWALL SEA | 180.00 | 90.00 | S | ||
F6WINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 NWALL NEA | 0.00 | 90.00 | N | ||
F6WINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F6 EWALL NEA | 90.00 | 90.00 | E | ||
F6WINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 NWALL N1A | 0.00 | 90.00 | N | ||
F6WINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 NWALL N2A | 0.00 | 90.00 | N | ||
F6WINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 SWALL S1A | 180.00 | 90.00 | S | ||
F6WINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F6 SWALL S2A | 180.00 | 90.00 | S | ||
F6WINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F6 WWALL C | 270.00 | 90.00 | W | ||
F6WINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F6 EWALL C | 90.00 | 90.00 | E | ||
F7WINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F7 WWALL SWA | 270.00 | 90.00 | W | ||
F7WINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 SWALL SWA | 180.00 | 90.00 | S | ||
F7WINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 NWALL NWA | 0.00 | 90.00 | N | ||
F7WINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F7 WWALL NWA | 270.00 | 90.00 | W | ||
F7WINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F7 EWALL SEA | 90.00 | 90.00 | E | ||
F7WINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 SWALL SEA | 180.00 | 90.00 | S | ||
F7WINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 NWALL NEA | 0.00 | 90.00 | N | ||
F7WINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F7 EWALL NEA | 90.00 | 90.00 | E | ||
F7WINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 NWALL N1A | 0.00 | 90.00 | N | ||
F7WINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 NWALL N2A | 0.00 | 90.00 | N | ||
F7WINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 SWALL S1A | 180.00 | 90.00 | S | ||
F7WINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F7 SWALL S2A | 180.00 | 90.00 | S | ||
F7WINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F7 WWALL C | 270.00 | 90.00 | W | ||
F7WINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F7 EWALL C | 90.00 | 90.00 | E | ||
F8WINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F8 WWALL SWA | 270.00 | 90.00 | W | ||
F8WINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 SWALL SWA | 180.00 | 90.00 | S | ||
F8WINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 NWALL NWA | 0.00 | 90.00 | N | ||
F8WINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F8 WWALL NWA | 270.00 | 90.00 | W | ||
F8WINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F8 EWALL SEA | 90.00 | 90.00 | E | ||
F8WINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 SWALL SEA | 180.00 | 90.00 | S | ||
F8WINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 NWALL NEA | 0.00 | 90.00 | N | ||
F8WINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F8 EWALL NEA | 90.00 | 90.00 | E | ||
F8WINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 NWALL N1A | 0.00 | 90.00 | N | ||
F8WINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 NWALL N2A | 0.00 | 90.00 | N | ||
F8WINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 SWALL S1A | 180.00 | 90.00 | S | ||
F8WINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F8 SWALL S2A | 180.00 | 90.00 | S | ||
F8WINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F8 WWALL C | 270.00 | 90.00 | W | ||
F8WINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F8 EWALL C | 90.00 | 90.00 | E | ||
F9WINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F9 WWALL SWA | 270.00 | 90.00 | W | ||
F9WINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 SWALL SWA | 180.00 | 90.00 | S | ||
F9WINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 NWALL NWA | 0.00 | 90.00 | N | ||
F9WINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F9 WWALL NWA | 270.00 | 90.00 | W | ||
F9WINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F9 EWALL SEA | 90.00 | 90.00 | E | ||
F9WINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 SWALL SEA | 180.00 | 90.00 | S | ||
F9WINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 NWALL NEA | 0.00 | 90.00 | N | ||
F9WINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | F9 EWALL NEA | 90.00 | 90.00 | E | ||
F9WINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 NWALL N1A | 0.00 | 90.00 | N | ||
F9WINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 NWALL N2A | 0.00 | 90.00 | N | ||
F9WINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 SWALL S1A | 180.00 | 90.00 | S | ||
F9WINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | F9 SWALL S2A | 180.00 | 90.00 | S | ||
F9WINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F9 WWALL C | 270.00 | 90.00 | W | ||
F9WINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | F9 EWALL C | 90.00 | 90.00 | E | ||
TWINDOW2 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW3 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW4 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW6 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW8 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW5 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW7 | WINDOW_U_0.72_SHGC_0.25 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 4.600 | 0.293 | 0.130 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW9 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW10 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW11 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW12 | WINDOW_U_0.72_SHGC_0.25 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 4.600 | 0.293 | 0.130 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW13 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | T WWALL C | 270.00 | 90.00 | W | ||
TWINDOW14 | WINDOW_U_0.72_SHGC_0.25 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 4.600 | 0.293 | 0.130 | No | T EWALL C | 90.00 | 90.00 | E | ||
Total or Average | 1150.39 | 4.600 | 0.293 | 0.130 | ||||||||||||
North Total or Average | 423.59 | 4.600 | 0.293 | 0.130 | ||||||||||||
Non-North Total or Average | 726.80 | 4.600 | 0.293 | 0.130 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:57
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW4 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW5 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW9 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW10 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW11 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW12 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:57
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
G SW APARTMENT_LIGHTS_HARDWIRED | G SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G NW APARTMENT_LIGHTS_HARDWIRED | G NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
OFFICE_LIGHTS_HARDWIRED | OFFICE | 14.7681 | 88.25 | 1303.26 | GeneralLights | LTG_OFF_SCH | 62.05 | 168.00 | 61.07 | 0.0000 | Y | 14.94 |
G NE APARTMENT_LIGHTS_HARDWIRED | G NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G N1 APARTMENT_LIGHTS_HARDWIRED | G N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G N2 APARTMENT_LIGHTS_HARDWIRED | G N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G S1 APARTMENT_LIGHTS_HARDWIRED | G S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G S2 APARTMENT_LIGHTS_HARDWIRED | G S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G CORRIDOR_LIGHTS_HARDWIRED | G CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F2 SW APARTMENT_LIGHTS_HARDWIRED | F2 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 NW APARTMENT_LIGHTS_HARDWIRED | F2 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 SE APARTMENT_LIGHTS_HARDWIRED | F2 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 NE APARTMENT_LIGHTS_HARDWIRED | F2 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 N1 APARTMENT_LIGHTS_HARDWIRED | F2 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 N2 APARTMENT_LIGHTS_HARDWIRED | F2 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 S1 APARTMENT_LIGHTS_HARDWIRED | F2 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 S2 APARTMENT_LIGHTS_HARDWIRED | F2 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 CORRIDOR_LIGHTS_HARDWIRED | F2 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F3 SW APARTMENT_LIGHTS_HARDWIRED | F3 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 NW APARTMENT_LIGHTS_HARDWIRED | F3 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 SE APARTMENT_LIGHTS_HARDWIRED | F3 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 NE APARTMENT_LIGHTS_HARDWIRED | F3 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 N1 APARTMENT_LIGHTS_HARDWIRED | F3 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 N2 APARTMENT_LIGHTS_HARDWIRED | F3 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 S1 APARTMENT_LIGHTS_HARDWIRED | F3 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 S2 APARTMENT_LIGHTS_HARDWIRED | F3 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 CORRIDOR_LIGHTS_HARDWIRED | F3 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F4 SW APARTMENT_LIGHTS_HARDWIRED | F4 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 NW APARTMENT_LIGHTS_HARDWIRED | F4 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 SE APARTMENT_LIGHTS_HARDWIRED | F4 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 NE APARTMENT_LIGHTS_HARDWIRED | F4 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 N1 APARTMENT_LIGHTS_HARDWIRED | F4 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 N2 APARTMENT_LIGHTS_HARDWIRED | F4 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 S1 APARTMENT_LIGHTS_HARDWIRED | F4 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 S2 APARTMENT_LIGHTS_HARDWIRED | F4 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 CORRIDOR_LIGHTS_HARDWIRED | F4 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
M SW APARTMENT_LIGHTS_HARDWIRED | M SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M NW APARTMENT_LIGHTS_HARDWIRED | M NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M SE APARTMENT_LIGHTS_HARDWIRED | M SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M NE APARTMENT_LIGHTS_HARDWIRED | M NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M N1 APARTMENT_LIGHTS_HARDWIRED | M N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M N2 APARTMENT_LIGHTS_HARDWIRED | M N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M S1 APARTMENT_LIGHTS_HARDWIRED | M S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M S2 APARTMENT_LIGHTS_HARDWIRED | M S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M CORRIDOR_LIGHTS_HARDWIRED | M CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F6 SW APARTMENT_LIGHTS_HARDWIRED | F6 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 NW APARTMENT_LIGHTS_HARDWIRED | F6 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 SE APARTMENT_LIGHTS_HARDWIRED | F6 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 NE APARTMENT_LIGHTS_HARDWIRED | F6 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 N1 APARTMENT_LIGHTS_HARDWIRED | F6 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 N2 APARTMENT_LIGHTS_HARDWIRED | F6 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 S1 APARTMENT_LIGHTS_HARDWIRED | F6 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 S2 APARTMENT_LIGHTS_HARDWIRED | F6 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 CORRIDOR_LIGHTS_HARDWIRED | F6 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F7 SW APARTMENT_LIGHTS_HARDWIRED | F7 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 NW APARTMENT_LIGHTS_HARDWIRED | F7 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 SE APARTMENT_LIGHTS_HARDWIRED | F7 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 NE APARTMENT_LIGHTS_HARDWIRED | F7 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 N1 APARTMENT_LIGHTS_HARDWIRED | F7 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 N2 APARTMENT_LIGHTS_HARDWIRED | F7 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 S1 APARTMENT_LIGHTS_HARDWIRED | F7 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 S2 APARTMENT_LIGHTS_HARDWIRED | F7 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 CORRIDOR_LIGHTS_HARDWIRED | F7 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F8 SW APARTMENT_LIGHTS_HARDWIRED | F8 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 NW APARTMENT_LIGHTS_HARDWIRED | F8 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 SE APARTMENT_LIGHTS_HARDWIRED | F8 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 NE APARTMENT_LIGHTS_HARDWIRED | F8 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 N1 APARTMENT_LIGHTS_HARDWIRED | F8 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 N2 APARTMENT_LIGHTS_HARDWIRED | F8 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 S1 APARTMENT_LIGHTS_HARDWIRED | F8 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 S2 APARTMENT_LIGHTS_HARDWIRED | F8 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 CORRIDOR_LIGHTS_HARDWIRED | F8 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F9 SW APARTMENT_LIGHTS_HARDWIRED | F9 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 NW APARTMENT_LIGHTS_HARDWIRED | F9 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 SE APARTMENT_LIGHTS_HARDWIRED | F9 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 NE APARTMENT_LIGHTS_HARDWIRED | F9 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 N1 APARTMENT_LIGHTS_HARDWIRED | F9 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 N2 APARTMENT_LIGHTS_HARDWIRED | F9 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 S1 APARTMENT_LIGHTS_HARDWIRED | F9 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 S2 APARTMENT_LIGHTS_HARDWIRED | F9 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 CORRIDOR_LIGHTS_HARDWIRED | F9 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
T SW APARTMENT_LIGHTS_HARDWIRED | T SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T NW APARTMENT_LIGHTS_HARDWIRED | T NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T SE APARTMENT_LIGHTS_HARDWIRED | T SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T NE APARTMENT_LIGHTS_HARDWIRED | T NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T N1 APARTMENT_LIGHTS_HARDWIRED | T N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T N2 APARTMENT_LIGHTS_HARDWIRED | T N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T S1 APARTMENT_LIGHTS_HARDWIRED | T S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T S2 APARTMENT_LIGHTS_HARDWIRED | T S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T CORRIDOR_LIGHTS_HARDWIRED | T CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
G SW APARTMENT_LIGHTS_PLUGIN | G SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G NW APARTMENT_LIGHTS_PLUGIN | G NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
OFFICE_LIGHTS_PLUGIN | OFFICE | 14.7681 | 88.25 | 1303.26 | GeneralLights-plugin | LTG_OFF_SCH | 62.05 | 168.00 | 61.07 | 0.0000 | Y | 14.94 |
G NE APARTMENT_LIGHTS_PLUGIN | G NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G N1 APARTMENT_LIGHTS_PLUGIN | G N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G N2 APARTMENT_LIGHTS_PLUGIN | G N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G S1 APARTMENT_LIGHTS_PLUGIN | G S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G S2 APARTMENT_LIGHTS_PLUGIN | G S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 SW APARTMENT_LIGHTS_PLUGIN | F2 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 NW APARTMENT_LIGHTS_PLUGIN | F2 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 SE APARTMENT_LIGHTS_PLUGIN | F2 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 NE APARTMENT_LIGHTS_PLUGIN | F2 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 N1 APARTMENT_LIGHTS_PLUGIN | F2 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 N2 APARTMENT_LIGHTS_PLUGIN | F2 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 S1 APARTMENT_LIGHTS_PLUGIN | F2 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 S2 APARTMENT_LIGHTS_PLUGIN | F2 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 SW APARTMENT_LIGHTS_PLUGIN | F3 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 NW APARTMENT_LIGHTS_PLUGIN | F3 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 SE APARTMENT_LIGHTS_PLUGIN | F3 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 NE APARTMENT_LIGHTS_PLUGIN | F3 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 N1 APARTMENT_LIGHTS_PLUGIN | F3 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 N2 APARTMENT_LIGHTS_PLUGIN | F3 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 S1 APARTMENT_LIGHTS_PLUGIN | F3 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 S2 APARTMENT_LIGHTS_PLUGIN | F3 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 SW APARTMENT_LIGHTS_PLUGIN | F4 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 NW APARTMENT_LIGHTS_PLUGIN | F4 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 SE APARTMENT_LIGHTS_PLUGIN | F4 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 NE APARTMENT_LIGHTS_PLUGIN | F4 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 N1 APARTMENT_LIGHTS_PLUGIN | F4 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 N2 APARTMENT_LIGHTS_PLUGIN | F4 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 S1 APARTMENT_LIGHTS_PLUGIN | F4 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 S2 APARTMENT_LIGHTS_PLUGIN | F4 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M SW APARTMENT_LIGHTS_PLUGIN | M SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M NW APARTMENT_LIGHTS_PLUGIN | M NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M SE APARTMENT_LIGHTS_PLUGIN | M SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M NE APARTMENT_LIGHTS_PLUGIN | M NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M N1 APARTMENT_LIGHTS_PLUGIN | M N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M N2 APARTMENT_LIGHTS_PLUGIN | M N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M S1 APARTMENT_LIGHTS_PLUGIN | M S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M S2 APARTMENT_LIGHTS_PLUGIN | M S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M CORRIDOR_LIGHTS_PLUGIN | M CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights-plugin | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F6 SW APARTMENT_LIGHTS_PLUGIN | F6 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 NW APARTMENT_LIGHTS_PLUGIN | F6 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 SE APARTMENT_LIGHTS_PLUGIN | F6 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 NE APARTMENT_LIGHTS_PLUGIN | F6 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 N1 APARTMENT_LIGHTS_PLUGIN | F6 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 N2 APARTMENT_LIGHTS_PLUGIN | F6 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 S1 APARTMENT_LIGHTS_PLUGIN | F6 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 S2 APARTMENT_LIGHTS_PLUGIN | F6 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 SW APARTMENT_LIGHTS_PLUGIN | F7 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 NW APARTMENT_LIGHTS_PLUGIN | F7 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 SE APARTMENT_LIGHTS_PLUGIN | F7 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 NE APARTMENT_LIGHTS_PLUGIN | F7 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 N1 APARTMENT_LIGHTS_PLUGIN | F7 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 N2 APARTMENT_LIGHTS_PLUGIN | F7 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 S1 APARTMENT_LIGHTS_PLUGIN | F7 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 S2 APARTMENT_LIGHTS_PLUGIN | F7 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 SW APARTMENT_LIGHTS_PLUGIN | F8 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 NW APARTMENT_LIGHTS_PLUGIN | F8 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 SE APARTMENT_LIGHTS_PLUGIN | F8 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 NE APARTMENT_LIGHTS_PLUGIN | F8 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 N1 APARTMENT_LIGHTS_PLUGIN | F8 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 N2 APARTMENT_LIGHTS_PLUGIN | F8 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 S1 APARTMENT_LIGHTS_PLUGIN | F8 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 S2 APARTMENT_LIGHTS_PLUGIN | F8 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 SW APARTMENT_LIGHTS_PLUGIN | F9 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 NW APARTMENT_LIGHTS_PLUGIN | F9 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 SE APARTMENT_LIGHTS_PLUGIN | F9 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 NE APARTMENT_LIGHTS_PLUGIN | F9 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 N1 APARTMENT_LIGHTS_PLUGIN | F9 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 N2 APARTMENT_LIGHTS_PLUGIN | F9 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 S1 APARTMENT_LIGHTS_PLUGIN | F9 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 S2 APARTMENT_LIGHTS_PLUGIN | F9 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T SW APARTMENT_LIGHTS_PLUGIN | T SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T NW APARTMENT_LIGHTS_PLUGIN | T NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T SE APARTMENT_LIGHTS_PLUGIN | T SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T NE APARTMENT_LIGHTS_PLUGIN | T NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T N1 APARTMENT_LIGHTS_PLUGIN | T N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T N2 APARTMENT_LIGHTS_PLUGIN | T N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T S1 APARTMENT_LIGHTS_PLUGIN | T S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T S2 APARTMENT_LIGHTS_PLUGIN | T S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
Interior Lighting Total | 2.2679 | 14974.03 | 33959.19 | 296.56 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 10364.00 | AstronomicalClock | - | 83.71 | 83.71 | 162.86 | |
Exterior Lighting Total | 10364.00 | 162.86 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:57
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
CENTRAL BOILER | Boiler:HotWater | 347922.84 | 0.75 | ||
CENTRAL TOWER | EvaporativeFluidCooler:SingleSpeed | 278338.27 |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
HEAT PUMP COOLING MODE AIRLOOP G SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4608.67 | 3128.39 | 1480.28 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4679.76 | 3185.09 | 1494.67 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP OFFICE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6206.62 | 4237.38 | 1969.23 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3858.00 | 2571.04 | 1286.96 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2735.61 | 1742.48 | 993.13 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2719.38 | 1730.42 | 988.96 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2760.70 | 1745.35 | 1015.35 | 0.63 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2844.61 | 1808.67 | 1035.94 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5325.85 | 3639.85 | 1686.00 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5397.15 | 3694.82 | 1702.33 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4908.14 | 3327.10 | 1581.04 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4499.55 | 3022.68 | 1476.86 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3205.84 | 2075.61 | 1130.23 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3193.10 | 2066.10 | 1127.01 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3237.26 | 2085.92 | 1151.34 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3265.91 | 2107.62 | 1158.29 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5394.79 | 3668.54 | 1726.25 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5468.75 | 3725.42 | 1743.33 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4696.98 | 3143.00 | 1553.98 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4576.48 | 3058.90 | 1517.58 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3272.61 | 2114.19 | 1158.43 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3259.96 | 2104.76 | 1155.20 | 0.65 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3308.04 | 2127.80 | 1180.24 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3319.52 | 2136.49 | 1183.02 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5451.62 | 3694.22 | 1757.40 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5524.82 | 3750.42 | 1774.40 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4718.56 | 3142.93 | 1575.63 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4633.39 | 3083.82 | 1549.57 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3320.05 | 2141.18 | 1178.87 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3307.46 | 2131.82 | 1175.64 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3354.28 | 2154.07 | 1200.22 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3363.09 | 2160.73 | 1202.35 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5526.84 | 3737.31 | 1789.53 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5600.46 | 3793.75 | 1806.71 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4785.39 | 3180.37 | 1605.01 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4703.28 | 3123.64 | 1579.65 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3387.85 | 2185.00 | 1202.85 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3375.33 | 2175.71 | 1199.62 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3419.96 | 2196.49 | 1223.47 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3428.32 | 2202.82 | 1225.51 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5523.95 | 3721.49 | 1802.46 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5590.33 | 3773.87 | 1816.45 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4772.72 | 3159.74 | 1612.98 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4688.82 | 3101.74 | 1587.08 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3372.72 | 2167.85 | 1204.86 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3360.28 | 2158.65 | 1201.63 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3405.06 | 2179.51 | 1225.55 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3413.32 | 2185.74 | 1227.58 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5540.59 | 3723.67 | 1816.92 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5606.28 | 3775.47 | 1830.81 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4785.33 | 3159.70 | 1625.63 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4700.78 | 3101.28 | 1599.49 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3383.77 | 2171.06 | 1212.70 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3371.40 | 2161.93 | 1209.47 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3415.24 | 2182.10 | 1233.14 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3423.44 | 2188.28 | 1235.16 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5574.45 | 3740.09 | 1834.36 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5639.71 | 3791.51 | 1848.20 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4815.18 | 3173.73 | 1641.45 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4729.75 | 3114.70 | 1615.05 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3413.26 | 2188.54 | 1224.72 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3400.99 | 2179.49 | 1221.50 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3442.85 | 2198.25 | 1244.59 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3451.01 | 2204.39 | 1246.61 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5733.40 | 3853.76 | 1879.65 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5807.39 | 3910.27 | 1897.13 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4908.53 | 3236.15 | 1672.38 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4818.08 | 3173.35 | 1644.73 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3567.04 | 2298.80 | 1268.24 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3554.79 | 2289.74 | 1265.05 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3560.38 | 2281.19 | 1279.19 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3568.40 | 2287.23 | 1281.17 | 0.64 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6798.46 | 4655.54 | 2142.92 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 6785.88 | 4646.86 | 2139.02 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5913.18 | 3973.93 | 1939.25 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5693.60 | 3821.80 | 1871.80 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4423.93 | 2927.63 | 1496.30 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4423.44 | 2927.36 | 1496.08 | 0.66 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4699.16 | 3136.60 | 1562.55 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4706.44 | 3142.23 | 1564.22 | 0.67 | 0.00 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
None |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
HEAT PUMP HEATING MODE AIRLOOP G SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4608.67 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4679.76 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP OFFICE | Coil:Heating:WaterToAirHeatPump:EquationFit | 6206.62 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3858.00 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2735.61 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2719.38 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2760.70 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2844.61 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5325.85 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5397.15 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4908.14 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4499.55 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3205.84 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3193.10 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3237.26 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3265.91 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5394.79 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5468.75 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4696.98 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4576.48 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3272.61 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3259.96 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3308.04 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3319.52 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5451.62 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5524.82 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4718.56 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4633.39 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3320.05 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3307.46 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3354.28 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3363.09 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5526.84 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5600.46 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4785.39 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4703.28 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3387.85 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3375.33 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3419.96 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3428.32 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5523.95 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5590.33 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4772.72 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4688.82 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3372.72 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3360.28 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3405.06 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3413.32 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5540.59 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5606.28 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4785.33 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4700.78 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3383.77 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3371.40 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3415.24 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3423.44 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5574.45 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5639.71 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4815.18 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4729.75 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3413.26 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3400.99 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3442.85 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3451.01 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5733.40 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5807.39 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4908.53 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4818.08 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3567.04 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3554.79 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3560.38 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3568.40 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 6798.46 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 6785.88 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5913.18 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5693.60 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4423.93 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4423.44 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4699.16 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4706.44 | 0.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW | Coil:Heating:Electric | 2729.40 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW | Coil:Heating:Electric | 2722.15 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE | Coil:Heating:Electric | 3402.45 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE | Coil:Heating:Electric | 2722.15 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 | Coil:Heating:Electric | 1969.25 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 | Coil:Heating:Electric | 1969.25 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 | Coil:Heating:Electric | 1974.32 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 | Coil:Heating:Electric | 1980.66 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW | Coil:Heating:Electric | 2721.67 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW | Coil:Heating:Electric | 2714.59 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE | Coil:Heating:Electric | 2740.79 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE | Coil:Heating:Electric | 2714.59 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 | Coil:Heating:Electric | 1811.93 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 | Coil:Heating:Electric | 1811.93 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 | Coil:Heating:Electric | 1821.83 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 | Coil:Heating:Electric | 1823.15 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW | Coil:Heating:Electric | 2745.26 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW | Coil:Heating:Electric | 2741.58 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE | Coil:Heating:Electric | 2747.49 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE | Coil:Heating:Electric | 2741.58 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 | Coil:Heating:Electric | 1797.72 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 | Coil:Heating:Electric | 1797.72 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 | Coil:Heating:Electric | 1802.04 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 | Coil:Heating:Electric | 1802.26 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW | Coil:Heating:Electric | 2802.27 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW | Coil:Heating:Electric | 2801.60 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE | Coil:Heating:Electric | 2802.52 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE | Coil:Heating:Electric | 2801.60 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 | Coil:Heating:Electric | 1824.72 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 | Coil:Heating:Electric | 1824.72 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 | Coil:Heating:Electric | 1825.72 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 | Coil:Heating:Electric | 1825.75 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW | Coil:Heating:Electric | 2837.60 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW | Coil:Heating:Electric | 2838.34 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE | Coil:Heating:Electric | 2837.63 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE | Coil:Heating:Electric | 2838.34 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 | Coil:Heating:Electric | 1835.93 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 | Coil:Heating:Electric | 1835.93 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 | Coil:Heating:Electric | 1835.43 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 | Coil:Heating:Electric | 1835.43 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW | Coil:Heating:Electric | 2926.03 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW | Coil:Heating:Electric | 2929.62 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE | Coil:Heating:Electric | 2926.04 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE | Coil:Heating:Electric | 2929.62 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 | Coil:Heating:Electric | 1902.67 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 | Coil:Heating:Electric | 1902.67 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 | Coil:Heating:Electric | 1899.30 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 | Coil:Heating:Electric | 1899.30 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW | Coil:Heating:Electric | 2989.08 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW | Coil:Heating:Electric | 2994.24 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE | Coil:Heating:Electric | 2989.08 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE | Coil:Heating:Electric | 2994.24 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 | Coil:Heating:Electric | 1947.11 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 | Coil:Heating:Electric | 1947.11 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 | Coil:Heating:Electric | 1942.14 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 | Coil:Heating:Electric | 1942.14 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW | Coil:Heating:Electric | 3053.65 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW | Coil:Heating:Electric | 3060.05 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE | Coil:Heating:Electric | 3053.65 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE | Coil:Heating:Electric | 3060.05 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 | Coil:Heating:Electric | 1994.93 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 | Coil:Heating:Electric | 1994.93 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 | Coil:Heating:Electric | 1988.72 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 | Coil:Heating:Electric | 1988.72 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW | Coil:Heating:Electric | 3215.62 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW | Coil:Heating:Electric | 3221.28 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE | Coil:Heating:Electric | 3215.62 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE | Coil:Heating:Electric | 3221.28 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 | Coil:Heating:Electric | 2132.63 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 | Coil:Heating:Electric | 2132.63 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 | Coil:Heating:Electric | 2126.92 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 | Coil:Heating:Electric | 2126.92 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW | Coil:Heating:Electric | 3713.56 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW | Coil:Heating:Electric | 3724.56 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE | Coil:Heating:Electric | 3713.56 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE | Coil:Heating:Electric | 3724.56 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 | Coil:Heating:Electric | 2666.51 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 | Coil:Heating:Electric | 2666.51 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 | Coil:Heating:Electric | 2654.60 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 | Coil:Heating:Electric | 2654.60 | 1.00 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
AIRLOOP G SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 293.09 | 1160.84 | 1.00 | General |
AIRLOOP G NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.26 | 299.80 | 1160.84 | 1.00 | General |
AIRLOOP OFFICE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.34 | 399.77 | 1160.84 | 1.00 | General |
AIRLOOP G NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.20 | 237.10 | 1160.84 | 1.00 | General |
AIRLOOP G N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.13 | 150.99 | 1160.84 | 1.00 | General |
AIRLOOP G N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.13 | 149.73 | 1160.84 | 1.00 | General |
AIRLOOP G S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.13 | 148.47 | 1160.84 | 1.00 | General |
AIRLOOP G S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.13 | 155.12 | 1160.84 | 1.00 | General |
AIRLOOP F2 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 344.55 | 1160.84 | 1.00 | General |
AIRLOOP F2 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 350.81 | 1160.84 | 1.00 | General |
AIRLOOP F2 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 312.74 | 1160.84 | 1.00 | General |
AIRLOOP F2 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 282.02 | 1160.84 | 1.00 | General |
AIRLOOP F2 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 184.15 | 1160.84 | 1.00 | General |
AIRLOOP F2 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 183.15 | 1160.84 | 1.00 | General |
AIRLOOP F2 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 182.57 | 1160.84 | 1.00 | General |
AIRLOOP F2 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 184.86 | 1160.84 | 1.00 | General |
AIRLOOP F3 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 345.84 | 1160.84 | 1.00 | General |
AIRLOOP F3 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 352.29 | 1160.84 | 1.00 | General |
AIRLOOP F3 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 291.52 | 1160.84 | 1.00 | General |
AIRLOOP F3 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 284.12 | 1160.84 | 1.00 | General |
AIRLOOP F3 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 187.19 | 1160.84 | 1.00 | General |
AIRLOOP F3 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 186.20 | 1160.84 | 1.00 | General |
AIRLOOP F3 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 185.98 | 1160.84 | 1.00 | General |
AIRLOOP F3 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 186.90 | 1160.84 | 1.00 | General |
AIRLOOP F4 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 347.24 | 1160.84 | 1.00 | General |
AIRLOOP F4 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 353.62 | 1160.84 | 1.00 | General |
AIRLOOP F4 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 290.22 | 1160.84 | 1.00 | General |
AIRLOOP F4 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 285.00 | 1160.84 | 1.00 | General |
AIRLOOP F4 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 189.27 | 1160.84 | 1.00 | General |
AIRLOOP F4 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 188.29 | 1160.84 | 1.00 | General |
AIRLOOP F4 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 187.99 | 1160.84 | 1.00 | General |
AIRLOOP F4 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 188.70 | 1160.84 | 1.00 | General |
AIRLOOP M SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 350.73 | 1160.84 | 1.00 | General |
AIRLOOP M NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 357.12 | 1160.84 | 1.00 | General |
AIRLOOP M SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 293.12 | 1160.84 | 1.00 | General |
AIRLOOP M NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 288.15 | 1160.84 | 1.00 | General |
AIRLOOP M N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 193.26 | 1160.84 | 1.00 | General |
AIRLOOP M N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 192.29 | 1160.84 | 1.00 | General |
AIRLOOP M S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 191.84 | 1160.84 | 1.00 | General |
AIRLOOP M S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 192.51 | 1160.84 | 1.00 | General |
AIRLOOP F6 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 347.86 | 1160.84 | 1.00 | General |
AIRLOOP F6 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 354.11 | 1160.84 | 1.00 | General |
AIRLOOP F6 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 290.04 | 1160.84 | 1.00 | General |
AIRLOOP F6 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 284.94 | 1160.84 | 1.00 | General |
AIRLOOP F6 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 190.92 | 1160.84 | 1.00 | General |
AIRLOOP F6 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 189.96 | 1160.84 | 1.00 | General |
AIRLOOP F6 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 189.54 | 1160.84 | 1.00 | General |
AIRLOOP F6 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 190.20 | 1160.84 | 1.00 | General |
AIRLOOP F7 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 347.29 | 1160.84 | 1.00 | General |
AIRLOOP F7 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 353.47 | 1160.84 | 1.00 | General |
AIRLOOP F7 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 289.25 | 1160.84 | 1.00 | General |
AIRLOOP F7 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 284.10 | 1160.84 | 1.00 | General |
AIRLOOP F7 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 190.79 | 1160.84 | 1.00 | General |
AIRLOOP F7 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 189.84 | 1160.84 | 1.00 | General |
AIRLOOP F7 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 189.35 | 1160.84 | 1.00 | General |
AIRLOOP F7 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 190.01 | 1160.84 | 1.00 | General |
AIRLOOP F8 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 348.30 | 1160.84 | 1.00 | General |
AIRLOOP F8 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 354.44 | 1160.84 | 1.00 | General |
AIRLOOP F8 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 290.03 | 1160.84 | 1.00 | General |
AIRLOOP F8 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 284.82 | 1160.84 | 1.00 | General |
AIRLOOP F8 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 192.21 | 1160.84 | 1.00 | General |
AIRLOOP F8 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 191.27 | 1160.84 | 1.00 | General |
AIRLOOP F8 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 190.64 | 1160.84 | 1.00 | General |
AIRLOOP F8 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 191.29 | 1160.84 | 1.00 | General |
AIRLOOP F9 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 359.92 | 1160.84 | 1.00 | General |
AIRLOOP F9 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 366.32 | 1160.84 | 1.00 | General |
AIRLOOP F9 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 295.96 | 1160.84 | 1.00 | General |
AIRLOOP F9 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 290.35 | 1160.84 | 1.00 | General |
AIRLOOP F9 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 203.42 | 1160.84 | 1.00 | General |
AIRLOOP F9 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 202.48 | 1160.84 | 1.00 | General |
AIRLOOP F9 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 198.83 | 1160.84 | 1.00 | General |
AIRLOOP F9 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 199.47 | 1160.84 | 1.00 | General |
AIRLOOP T SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.38 | 443.53 | 1160.84 | 1.00 | General |
AIRLOOP T NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.38 | 442.86 | 1160.84 | 1.00 | General |
AIRLOOP T SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 370.31 | 1160.84 | 1.00 | General |
AIRLOOP T NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 357.16 | 1160.84 | 1.00 | General |
AIRLOOP T N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 266.45 | 1160.84 | 1.00 | General |
AIRLOOP T N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 266.43 | 1160.84 | 1.00 | General |
AIRLOOP T S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 288.47 | 1160.84 | 1.00 | General |
AIRLOOP T S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 289.07 | 1160.84 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
SHWSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.0003 | 36.93 | 127739.32 | 0.30 |
PLANT CIRC PUMP | Pump:ConstantSpeed | Intermittent | 224180.02 | 0.0076 | 2416.67 | 319344.75 | 0.90 |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SHWSYS1 WATER HEATER | WaterHeater:Mixed | 2.27 | 175842.64 | 0.80 | 0.00 | 0.00 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:57
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 2677.56 | 3213.07 | 0.210 | 0.252 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 34.79 | 0.01519 |
G NW APARTMENT | 2738.97 | 3286.76 | 0.215 | 0.258 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 34.08 | 0.01519 |
OFFICE | 3652.23 | 4382.67 | 0.287 | 0.344 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 33.30 | 0.01519 |
G NE APARTMENT | 2166.08 | 2599.30 | 0.170 | 0.204 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 32.54 | 0.01519 |
G N1 APARTMENT | 1379.53 | 1655.43 | 0.108 | 0.130 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 32.82 | 0.01519 |
G N2 APARTMENT | 1367.96 | 1641.56 | 0.107 | 0.129 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 32.82 | 0.01519 |
G S1 APARTMENT | 1356.45 | 1627.74 | 0.107 | 0.128 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 35.87 | 0.01519 |
G S2 APARTMENT | 1417.20 | 1700.64 | 0.111 | 0.134 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 35.87 | 0.01519 |
F2 SW APARTMENT | 3147.64 | 3777.17 | 0.247 | 0.297 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 34.59 | 0.01519 |
F2 NW APARTMENT | 3204.88 | 3845.85 | 0.252 | 0.302 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 34.08 | 0.01519 |
F2 SE APARTMENT | 2857.01 | 3428.42 | 0.225 | 0.269 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 33.68 | 0.01519 |
F2 NE APARTMENT | 2576.37 | 3091.64 | 0.202 | 0.243 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 32.54 | 0.01519 |
F2 N1 APARTMENT | 1682.40 | 2018.88 | 0.132 | 0.159 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 33.20 | 0.01519 |
F2 N2 APARTMENT | 1673.28 | 2007.94 | 0.131 | 0.158 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 33.20 | 0.01519 |
F2 S1 APARTMENT | 1667.96 | 2001.55 | 0.131 | 0.157 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 35.87 | 0.01519 |
F2 S2 APARTMENT | 1688.84 | 2026.60 | 0.133 | 0.159 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 35.87 | 0.01519 |
F3 SW APARTMENT | 3159.27 | 3791.13 | 0.248 | 0.298 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 34.59 | 0.01519 |
F3 NW APARTMENT | 3218.33 | 3862.00 | 0.253 | 0.303 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 34.08 | 0.01519 |
F3 SE APARTMENT | 2663.10 | 3195.72 | 0.209 | 0.251 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 33.68 | 0.01519 |
F3 NE APARTMENT | 2595.42 | 3114.50 | 0.204 | 0.245 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 32.54 | 0.01519 |
F3 N1 APARTMENT | 1710.19 | 2052.23 | 0.134 | 0.161 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 33.20 | 0.01519 |
F3 N2 APARTMENT | 1701.17 | 2041.40 | 0.134 | 0.160 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 33.20 | 0.01519 |
F3 S1 APARTMENT | 1699.06 | 2038.87 | 0.134 | 0.160 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 35.87 | 0.01519 |
F3 S2 APARTMENT | 1707.44 | 2048.93 | 0.134 | 0.161 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 35.87 | 0.01519 |
F4 SW APARTMENT | 3172.03 | 3806.44 | 0.249 | 0.299 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 34.59 | 0.01519 |
F4 NW APARTMENT | 3230.40 | 3876.48 | 0.254 | 0.305 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 34.08 | 0.01519 |
F4 SE APARTMENT | 2651.14 | 3181.37 | 0.208 | 0.250 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 33.68 | 0.01519 |
F4 NE APARTMENT | 2603.45 | 3124.14 | 0.205 | 0.246 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 32.92 | 0.01519 |
F4 N1 APARTMENT | 1729.17 | 2075.00 | 0.136 | 0.163 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 33.20 | 0.01519 |
F4 N2 APARTMENT | 1720.21 | 2064.26 | 0.135 | 0.162 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 33.20 | 0.01519 |
F4 S1 APARTMENT | 1717.43 | 2060.91 | 0.135 | 0.162 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 35.87 | 0.01519 |
F4 S2 APARTMENT | 1723.86 | 2068.63 | 0.135 | 0.163 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 35.87 | 0.01519 |
M SW APARTMENT | 3203.82 | 3844.58 | 0.252 | 0.302 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 34.59 | 0.01519 |
M NW APARTMENT | 3262.41 | 3914.89 | 0.256 | 0.308 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 34.08 | 0.01519 |
M SE APARTMENT | 2677.59 | 3213.11 | 0.210 | 0.253 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 33.68 | 0.01519 |
M NE APARTMENT | 2632.19 | 3158.63 | 0.207 | 0.248 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 32.92 | 0.01519 |
M N1 APARTMENT | 1765.64 | 2118.77 | 0.139 | 0.166 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 33.20 | 0.01519 |
M N2 APARTMENT | 1756.75 | 2108.10 | 0.138 | 0.166 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 33.20 | 0.01519 |
M S1 APARTMENT | 1752.53 | 2103.04 | 0.138 | 0.165 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 35.87 | 0.01519 |
M S2 APARTMENT | 1758.64 | 2110.37 | 0.138 | 0.166 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 35.87 | 0.01519 |
F6 SW APARTMENT | 3177.59 | 3813.11 | 0.250 | 0.300 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 34.79 | 0.01519 |
F6 NW APARTMENT | 3234.81 | 3881.77 | 0.254 | 0.305 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 34.08 | 0.01519 |
F6 SE APARTMENT | 2649.45 | 3179.34 | 0.208 | 0.250 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 33.68 | 0.01519 |
F6 NE APARTMENT | 2602.82 | 3123.39 | 0.205 | 0.245 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 32.92 | 0.01519 |
F6 N1 APARTMENT | 1744.24 | 2093.09 | 0.137 | 0.164 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 33.20 | 0.01519 |
F6 N2 APARTMENT | 1735.45 | 2082.55 | 0.136 | 0.164 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 33.20 | 0.01519 |
F6 S1 APARTMENT | 1731.50 | 2077.79 | 0.136 | 0.163 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 35.87 | 0.01519 |
F6 S2 APARTMENT | 1737.51 | 2085.01 | 0.137 | 0.164 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 35.87 | 0.01519 |
F7 SW APARTMENT | 3172.33 | 3806.80 | 0.249 | 0.299 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 34.79 | 0.01519 |
F7 NW APARTMENT | 3228.97 | 3874.77 | 0.254 | 0.304 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 34.08 | 0.01519 |
F7 SE APARTMENT | 2642.19 | 3170.63 | 0.208 | 0.249 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 33.68 | 0.01519 |
F7 NE APARTMENT | 2595.16 | 3114.19 | 0.204 | 0.245 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 32.92 | 0.01519 |
F7 N1 APARTMENT | 1743.05 | 2091.66 | 0.137 | 0.164 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 33.20 | 0.01519 |
F7 N2 APARTMENT | 1734.34 | 2081.21 | 0.136 | 0.164 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 33.20 | 0.01519 |
F7 S1 APARTMENT | 1729.81 | 2075.77 | 0.136 | 0.163 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 35.87 | 0.01519 |
F7 S2 APARTMENT | 1735.77 | 2082.92 | 0.136 | 0.164 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 35.87 | 0.01519 |
F8 SW APARTMENT | 3181.57 | 3817.88 | 0.250 | 0.300 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 34.79 | 0.01519 |
F8 NW APARTMENT | 3237.83 | 3885.40 | 0.254 | 0.305 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 34.08 | 0.01519 |
F8 SE APARTMENT | 2649.24 | 3179.09 | 0.208 | 0.250 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 33.68 | 0.01519 |
F8 NE APARTMENT | 2601.62 | 3121.94 | 0.204 | 0.245 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 32.92 | 0.01519 |
F8 N1 APARTMENT | 1756.02 | 2107.23 | 0.138 | 0.166 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 33.20 | 0.01519 |
F8 N2 APARTMENT | 1747.39 | 2096.87 | 0.137 | 0.165 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 33.20 | 0.01519 |
F8 S1 APARTMENT | 1741.54 | 2089.85 | 0.137 | 0.164 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 35.87 | 0.01519 |
F8 S2 APARTMENT | 1747.46 | 2096.96 | 0.137 | 0.165 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 35.87 | 0.01519 |
F9 SW APARTMENT | 3287.68 | 3945.22 | 0.258 | 0.310 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 34.59 | 0.01519 |
F9 NW APARTMENT | 3346.31 | 4015.57 | 0.263 | 0.316 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 34.08 | 0.01519 |
F9 SE APARTMENT | 2703.37 | 3244.04 | 0.212 | 0.255 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 33.68 | 0.01519 |
F9 NE APARTMENT | 2652.14 | 3182.56 | 0.208 | 0.250 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 32.92 | 0.01519 |
F9 N1 APARTMENT | 1858.44 | 2230.12 | 0.146 | 0.175 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 33.20 | 0.01519 |
F9 N2 APARTMENT | 1849.79 | 2219.75 | 0.145 | 0.174 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 33.20 | 0.01519 |
F9 S1 APARTMENT | 1816.33 | 2179.60 | 0.143 | 0.171 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 36.00 | 0.01519 |
F9 S2 APARTMENT | 1822.17 | 2186.60 | 0.143 | 0.172 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 36.00 | 0.01519 |
T SW APARTMENT | 4051.32 | 4861.58 | 0.318 | 0.382 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 34.99 | 0.01519 |
T NW APARTMENT | 4045.16 | 4854.19 | 0.318 | 0.381 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 34.79 | 0.01519 |
T SE APARTMENT | 3382.49 | 4058.99 | 0.266 | 0.319 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 35.87 | 0.01519 |
T NE APARTMENT | 3262.33 | 3914.79 | 0.256 | 0.308 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 33.68 | 0.01519 |
T N1 APARTMENT | 2434.04 | 2920.85 | 0.191 | 0.230 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 36.00 | 0.01519 |
T N2 APARTMENT | 2433.85 | 2920.62 | 0.191 | 0.230 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 36.00 | 0.01519 |
T S1 APARTMENT | 2635.23 | 3162.27 | 0.207 | 0.249 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 36.00 | 0.01519 |
T S2 APARTMENT | 2640.70 | 3168.84 | 0.208 | 0.249 | HOUSTON BUSH INTERCONTINENTAL ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 36.00 | 0.01519 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 1691.44 | 2029.73 | 0.076 | 0.091 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -1.60 | 0.00331 |
G NW APARTMENT | 1685.31 | 2022.37 | 0.075 | 0.090 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -1.60 | 0.00331 |
OFFICE | 1971.87 | 2366.25 | 0.088 | 0.106 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 18:45:00 | -1.60 | 0.00331 |
G NE APARTMENT | 1685.31 | 2022.37 | 0.075 | 0.090 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -1.60 | 0.00331 |
G N1 APARTMENT | 1048.61 | 1258.33 | 0.047 | 0.056 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -1.60 | 0.00331 |
G N2 APARTMENT | 1048.61 | 1258.33 | 0.047 | 0.056 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -1.60 | 0.00331 |
G S1 APARTMENT | 1052.89 | 1263.47 | 0.047 | 0.056 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -1.60 | 0.00331 |
G S2 APARTMENT | 1058.26 | 1269.91 | 0.047 | 0.057 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -1.60 | 0.00331 |
F2 SW APARTMENT | 1684.93 | 2021.91 | 0.075 | 0.090 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F2 NW APARTMENT | 1678.94 | 2014.73 | 0.075 | 0.090 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F2 SE APARTMENT | 1701.09 | 2041.31 | 0.076 | 0.091 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F2 NE APARTMENT | 1678.94 | 2014.73 | 0.075 | 0.090 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F2 N1 APARTMENT | 915.59 | 1098.71 | 0.041 | 0.049 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F2 N2 APARTMENT | 915.59 | 1098.71 | 0.041 | 0.049 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F2 S1 APARTMENT | 923.96 | 1108.75 | 0.041 | 0.050 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F2 S2 APARTMENT | 925.08 | 1110.09 | 0.041 | 0.050 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F3 SW APARTMENT | 1704.88 | 2045.85 | 0.076 | 0.091 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F3 NW APARTMENT | 1701.77 | 2042.12 | 0.076 | 0.091 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F3 SE APARTMENT | 1706.77 | 2048.12 | 0.076 | 0.091 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F3 NE APARTMENT | 1701.77 | 2042.12 | 0.076 | 0.091 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F3 N1 APARTMENT | 903.57 | 1084.29 | 0.040 | 0.048 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F3 N2 APARTMENT | 903.57 | 1084.29 | 0.040 | 0.048 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F3 S1 APARTMENT | 907.23 | 1088.67 | 0.041 | 0.049 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F3 S2 APARTMENT | 907.41 | 1088.89 | 0.041 | 0.049 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F4 SW APARTMENT | 1753.10 | 2103.72 | 0.078 | 0.094 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F4 NW APARTMENT | 1752.53 | 2103.03 | 0.078 | 0.094 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F4 SE APARTMENT | 1753.31 | 2103.97 | 0.078 | 0.094 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F4 NE APARTMENT | 1752.53 | 2103.03 | 0.078 | 0.094 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F4 N1 APARTMENT | 926.41 | 1111.69 | 0.041 | 0.050 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F4 N2 APARTMENT | 926.41 | 1111.69 | 0.041 | 0.050 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F4 S1 APARTMENT | 927.26 | 1112.71 | 0.041 | 0.050 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F4 S2 APARTMENT | 927.28 | 1112.74 | 0.041 | 0.050 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
M SW APARTMENT | 1782.98 | 2139.57 | 0.080 | 0.096 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
M NW APARTMENT | 1783.60 | 2140.32 | 0.080 | 0.096 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
M SE APARTMENT | 1783.00 | 2139.60 | 0.080 | 0.096 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
M NE APARTMENT | 1783.60 | 2140.32 | 0.080 | 0.096 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
M N1 APARTMENT | 935.89 | 1123.07 | 0.042 | 0.050 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
M N2 APARTMENT | 935.89 | 1123.07 | 0.042 | 0.050 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
M S1 APARTMENT | 935.47 | 1122.56 | 0.042 | 0.050 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
M S2 APARTMENT | 935.47 | 1122.57 | 0.042 | 0.050 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F6 SW APARTMENT | 1857.77 | 2229.32 | 0.083 | 0.100 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F6 NW APARTMENT | 1860.79 | 2232.95 | 0.083 | 0.100 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F6 SE APARTMENT | 1857.77 | 2229.32 | 0.083 | 0.100 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F6 NE APARTMENT | 1860.79 | 2232.95 | 0.083 | 0.100 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F6 N1 APARTMENT | 992.34 | 1190.80 | 0.044 | 0.053 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F6 N2 APARTMENT | 992.34 | 1190.80 | 0.044 | 0.053 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F6 S1 APARTMENT | 989.49 | 1187.38 | 0.044 | 0.053 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F6 S2 APARTMENT | 989.49 | 1187.38 | 0.044 | 0.053 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F7 SW APARTMENT | 1911.08 | 2293.30 | 0.085 | 0.102 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F7 NW APARTMENT | 1915.45 | 2298.54 | 0.086 | 0.103 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F7 SE APARTMENT | 1911.08 | 2293.30 | 0.085 | 0.102 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F7 NE APARTMENT | 1915.45 | 2298.54 | 0.086 | 0.103 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F7 N1 APARTMENT | 1029.92 | 1235.90 | 0.046 | 0.055 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F7 N2 APARTMENT | 1029.92 | 1235.90 | 0.046 | 0.055 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F7 S1 APARTMENT | 1025.71 | 1230.86 | 0.046 | 0.055 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F7 S2 APARTMENT | 1025.72 | 1230.86 | 0.046 | 0.055 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F8 SW APARTMENT | 1965.69 | 2358.83 | 0.088 | 0.105 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F8 NW APARTMENT | 1971.10 | 2365.32 | 0.088 | 0.106 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F8 SE APARTMENT | 1965.69 | 2358.83 | 0.088 | 0.105 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F8 NE APARTMENT | 1971.10 | 2365.32 | 0.088 | 0.106 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F8 N1 APARTMENT | 1070.36 | 1284.43 | 0.048 | 0.057 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F8 N2 APARTMENT | 1070.36 | 1284.43 | 0.048 | 0.057 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F8 S1 APARTMENT | 1065.10 | 1278.13 | 0.048 | 0.057 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F8 S2 APARTMENT | 1065.10 | 1278.13 | 0.048 | 0.057 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F9 SW APARTMENT | 2102.66 | 2523.19 | 0.094 | 0.113 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F9 NW APARTMENT | 2107.45 | 2528.94 | 0.094 | 0.113 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F9 SE APARTMENT | 2102.66 | 2523.19 | 0.094 | 0.113 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F9 NE APARTMENT | 2107.45 | 2528.94 | 0.094 | 0.113 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F9 N1 APARTMENT | 1186.81 | 1424.17 | 0.053 | 0.064 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F9 N2 APARTMENT | 1186.81 | 1424.17 | 0.053 | 0.064 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F9 S1 APARTMENT | 1181.98 | 1418.37 | 0.053 | 0.063 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
F9 S2 APARTMENT | 1181.98 | 1418.37 | 0.053 | 0.063 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
T SW APARTMENT | 2523.75 | 3028.50 | 0.113 | 0.135 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
T NW APARTMENT | 2533.06 | 3039.67 | 0.113 | 0.136 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
T SE APARTMENT | 2523.75 | 3028.50 | 0.113 | 0.135 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
T NE APARTMENT | 2533.06 | 3039.67 | 0.113 | 0.136 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
T N1 APARTMENT | 1638.29 | 1965.94 | 0.073 | 0.088 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
T N2 APARTMENT | 1638.29 | 1965.94 | 0.073 | 0.088 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
T S1 APARTMENT | 1628.22 | 1953.86 | 0.073 | 0.087 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
T S2 APARTMENT | 1628.22 | 1953.86 | 0.073 | 0.087 | HOUSTON BUSH INTERCONTINENTAL ANN HTG 99.6% CONDNS DB | 1/21 15:00:00 | -1.60 | 0.00331 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
AIRLOOP G SW | 0.25 | 0.25 | 0.09 | 0.09 |
AIRLOOP G NW | 0.26 | 0.26 | 0.09 | 0.09 |
AIRLOOP OFFICE | 0.34 | 0.34 | 0.11 | 0.11 |
AIRLOOP G NE | 0.20 | 0.20 | 0.09 | 0.09 |
AIRLOOP G N1 | 0.13 | 0.13 | 0.06 | 0.06 |
AIRLOOP G N2 | 0.13 | 0.13 | 0.06 | 0.06 |
AIRLOOP G S1 | 0.13 | 0.13 | 0.06 | 0.06 |
AIRLOOP G S2 | 0.13 | 0.13 | 0.06 | 0.06 |
AIRLOOP F2 SW | 0.30 | 0.30 | 0.09 | 0.09 |
AIRLOOP F2 NW | 0.30 | 0.30 | 0.09 | 0.09 |
AIRLOOP F2 SE | 0.27 | 0.27 | 0.09 | 0.09 |
AIRLOOP F2 NE | 0.24 | 0.24 | 0.09 | 0.09 |
AIRLOOP F2 N1 | 0.16 | 0.16 | 0.05 | 0.05 |
AIRLOOP F2 N2 | 0.16 | 0.16 | 0.05 | 0.05 |
AIRLOOP F2 S1 | 0.16 | 0.16 | 0.05 | 0.05 |
AIRLOOP F2 S2 | 0.16 | 0.16 | 0.05 | 0.05 |
AIRLOOP F3 SW | 0.30 | 0.30 | 0.09 | 0.09 |
AIRLOOP F3 NW | 0.30 | 0.30 | 0.09 | 0.09 |
AIRLOOP F3 SE | 0.25 | 0.25 | 0.09 | 0.09 |
AIRLOOP F3 NE | 0.24 | 0.24 | 0.09 | 0.09 |
AIRLOOP F3 N1 | 0.16 | 0.16 | 0.05 | 0.05 |
AIRLOOP F3 N2 | 0.16 | 0.16 | 0.05 | 0.05 |
AIRLOOP F3 S1 | 0.16 | 0.16 | 0.05 | 0.05 |
AIRLOOP F3 S2 | 0.16 | 0.16 | 0.05 | 0.05 |
AIRLOOP F4 SW | 0.30 | 0.30 | 0.09 | 0.09 |
AIRLOOP F4 NW | 0.30 | 0.30 | 0.09 | 0.09 |
AIRLOOP F4 SE | 0.25 | 0.25 | 0.09 | 0.09 |
AIRLOOP F4 NE | 0.25 | 0.25 | 0.09 | 0.09 |
AIRLOOP F4 N1 | 0.16 | 0.16 | 0.05 | 0.05 |
AIRLOOP F4 N2 | 0.16 | 0.16 | 0.05 | 0.05 |
AIRLOOP F4 S1 | 0.16 | 0.16 | 0.05 | 0.05 |
AIRLOOP F4 S2 | 0.16 | 0.16 | 0.05 | 0.05 |
AIRLOOP M SW | 0.30 | 0.30 | 0.10 | 0.10 |
AIRLOOP M NW | 0.31 | 0.31 | 0.10 | 0.10 |
AIRLOOP M SE | 0.25 | 0.25 | 0.10 | 0.10 |
AIRLOOP M NE | 0.25 | 0.25 | 0.10 | 0.10 |
AIRLOOP M N1 | 0.17 | 0.17 | 0.05 | 0.05 |
AIRLOOP M N2 | 0.17 | 0.17 | 0.05 | 0.05 |
AIRLOOP M S1 | 0.17 | 0.17 | 0.05 | 0.05 |
AIRLOOP M S2 | 0.17 | 0.17 | 0.05 | 0.05 |
AIRLOOP F6 SW | 0.30 | 0.30 | 0.10 | 0.10 |
AIRLOOP F6 NW | 0.31 | 0.31 | 0.10 | 0.10 |
AIRLOOP F6 SE | 0.25 | 0.25 | 0.10 | 0.10 |
AIRLOOP F6 NE | 0.25 | 0.25 | 0.10 | 0.10 |
AIRLOOP F6 N1 | 0.16 | 0.16 | 0.05 | 0.05 |
AIRLOOP F6 N2 | 0.16 | 0.16 | 0.05 | 0.05 |
AIRLOOP F6 S1 | 0.16 | 0.16 | 0.05 | 0.05 |
AIRLOOP F6 S2 | 0.16 | 0.16 | 0.05 | 0.05 |
AIRLOOP F7 SW | 0.30 | 0.30 | 0.10 | 0.10 |
AIRLOOP F7 NW | 0.30 | 0.30 | 0.10 | 0.10 |
AIRLOOP F7 SE | 0.25 | 0.25 | 0.10 | 0.10 |
AIRLOOP F7 NE | 0.24 | 0.24 | 0.10 | 0.10 |
AIRLOOP F7 N1 | 0.16 | 0.16 | 0.06 | 0.06 |
AIRLOOP F7 N2 | 0.16 | 0.16 | 0.06 | 0.06 |
AIRLOOP F7 S1 | 0.16 | 0.16 | 0.05 | 0.05 |
AIRLOOP F7 S2 | 0.16 | 0.16 | 0.05 | 0.05 |
AIRLOOP F8 SW | 0.30 | 0.30 | 0.11 | 0.11 |
AIRLOOP F8 NW | 0.31 | 0.31 | 0.11 | 0.11 |
AIRLOOP F8 SE | 0.25 | 0.25 | 0.11 | 0.11 |
AIRLOOP F8 NE | 0.25 | 0.25 | 0.11 | 0.11 |
AIRLOOP F8 N1 | 0.17 | 0.17 | 0.06 | 0.06 |
AIRLOOP F8 N2 | 0.16 | 0.16 | 0.06 | 0.06 |
AIRLOOP F8 S1 | 0.16 | 0.16 | 0.06 | 0.06 |
AIRLOOP F8 S2 | 0.16 | 0.16 | 0.06 | 0.06 |
AIRLOOP F9 SW | 0.31 | 0.31 | 0.11 | 0.11 |
AIRLOOP F9 NW | 0.32 | 0.32 | 0.11 | 0.11 |
AIRLOOP F9 SE | 0.25 | 0.25 | 0.11 | 0.11 |
AIRLOOP F9 NE | 0.25 | 0.25 | 0.11 | 0.11 |
AIRLOOP F9 N1 | 0.18 | 0.18 | 0.06 | 0.06 |
AIRLOOP F9 N2 | 0.17 | 0.17 | 0.06 | 0.06 |
AIRLOOP F9 S1 | 0.17 | 0.17 | 0.06 | 0.06 |
AIRLOOP F9 S2 | 0.17 | 0.17 | 0.06 | 0.06 |
AIRLOOP T SW | 0.38 | 0.38 | 0.14 | 0.14 |
AIRLOOP T NW | 0.38 | 0.38 | 0.14 | 0.14 |
AIRLOOP T SE | 0.32 | 0.32 | 0.14 | 0.14 |
AIRLOOP T NE | 0.31 | 0.31 | 0.14 | 0.14 |
AIRLOOP T N1 | 0.23 | 0.23 | 0.09 | 0.09 |
AIRLOOP T N2 | 0.23 | 0.23 | 0.09 | 0.09 |
AIRLOOP T S1 | 0.25 | 0.25 | 0.09 | 0.09 |
AIRLOOP T S2 | 0.25 | 0.25 | 0.09 | 0.09 |
Report: System Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:57
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 5474.75 | 5980.00 | 3083.25 |
G NW APARTMENT | 5324.00 | 6400.75 | 3183.75 |
OFFICE | 1617.75 | 320.50 | 15.25 |
G NE APARTMENT | 5306.75 | 6321.00 | 3066.00 |
G N1 APARTMENT | 5257.00 | 6583.25 | 3261.75 |
G N2 APARTMENT | 5254.50 | 6576.75 | 3252.50 |
G S1 APARTMENT | 5400.50 | 5993.25 | 3004.00 |
G S2 APARTMENT | 5425.00 | 5934.25 | 2991.25 |
F2 SW APARTMENT | 5910.25 | 4202.50 | 1923.25 |
F2 NW APARTMENT | 5581.25 | 4945.50 | 2093.00 |
F2 SE APARTMENT | 6014.00 | 3817.75 | 1683.50 |
F2 NE APARTMENT | 5563.25 | 4948.50 | 2064.00 |
F2 N1 APARTMENT | 5539.75 | 5070.75 | 2127.25 |
F2 N2 APARTMENT | 5537.00 | 5078.00 | 2130.50 |
F2 S1 APARTMENT | 5902.75 | 4076.75 | 1866.00 |
F2 S2 APARTMENT | 5917.25 | 4039.50 | 1850.50 |
F3 SW APARTMENT | 5993.75 | 4063.75 | 1893.25 |
F3 NW APARTMENT | 5653.00 | 4786.50 | 2030.00 |
F3 SE APARTMENT | 5990.50 | 3975.00 | 1795.75 |
F3 NE APARTMENT | 5620.50 | 4781.25 | 1978.00 |
F3 N1 APARTMENT | 5622.75 | 4800.50 | 1981.00 |
F3 N2 APARTMENT | 5618.75 | 4804.25 | 1978.25 |
F3 S1 APARTMENT | 6031.25 | 3756.25 | 1745.75 |
F3 S2 APARTMENT | 6033.25 | 3754.50 | 1746.25 |
F4 SW APARTMENT | 6018.50 | 4076.00 | 1931.00 |
F4 NW APARTMENT | 5672.00 | 4792.50 | 2059.25 |
F4 SE APARTMENT | 5985.00 | 4035.25 | 1846.50 |
F4 NE APARTMENT | 5631.25 | 4778.75 | 2000.25 |
F4 N1 APARTMENT | 5663.00 | 4740.50 | 1977.00 |
F4 N2 APARTMENT | 5657.00 | 4743.75 | 1976.50 |
F4 S1 APARTMENT | 6077.25 | 3702.00 | 1755.50 |
F4 S2 APARTMENT | 6075.00 | 3709.75 | 1756.25 |
M SW APARTMENT | 6007.00 | 4097.25 | 1933.00 |
M NW APARTMENT | 5666.75 | 4781.75 | 2049.75 |
M SE APARTMENT | 5969.75 | 4068.75 | 1851.50 |
M NE APARTMENT | 5630.00 | 4762.50 | 1985.00 |
M N1 APARTMENT | 5668.75 | 4701.75 | 1946.75 |
M N2 APARTMENT | 5664.50 | 4705.50 | 1946.25 |
M S1 APARTMENT | 6079.50 | 3696.50 | 1744.50 |
M S2 APARTMENT | 6074.50 | 3705.75 | 1745.25 |
F6 SW APARTMENT | 5932.25 | 4321.50 | 2053.75 |
F6 NW APARTMENT | 5602.75 | 4993.75 | 2191.25 |
F6 SE APARTMENT | 5884.00 | 4296.50 | 1970.25 |
F6 NE APARTMENT | 5570.75 | 4977.25 | 2128.75 |
F6 N1 APARTMENT | 5594.25 | 4880.50 | 2045.25 |
F6 N2 APARTMENT | 5590.00 | 4886.50 | 2046.75 |
F6 S1 APARTMENT | 5989.75 | 3943.75 | 1844.00 |
F6 S2 APARTMENT | 5983.00 | 3955.75 | 1846.25 |
F7 SW APARTMENT | 5877.25 | 4481.50 | 2136.00 |
F7 NW APARTMENT | 5561.50 | 5134.25 | 2279.25 |
F7 SE APARTMENT | 5825.00 | 4460.25 | 2057.75 |
F7 NE APARTMENT | 5539.00 | 5120.50 | 2211.00 |
F7 N1 APARTMENT | 5556.00 | 4987.50 | 2097.75 |
F7 N2 APARTMENT | 5553.50 | 4991.50 | 2096.25 |
F7 S1 APARTMENT | 5930.00 | 4104.00 | 1903.25 |
F7 S2 APARTMENT | 5927.00 | 4111.50 | 1905.75 |
F8 SW APARTMENT | 5830.75 | 4583.75 | 2179.75 |
F8 NW APARTMENT | 5537.25 | 5219.25 | 2330.75 |
F8 SE APARTMENT | 5773.25 | 4578.25 | 2113.25 |
F8 NE APARTMENT | 5509.00 | 5207.25 | 2252.00 |
F8 N1 APARTMENT | 5523.50 | 5058.75 | 2123.00 |
F8 N2 APARTMENT | 5520.50 | 5060.50 | 2119.75 |
F8 S1 APARTMENT | 5880.50 | 4204.50 | 1934.00 |
F8 S2 APARTMENT | 5877.50 | 4218.50 | 1938.25 |
F9 SW APARTMENT | 5783.25 | 4619.25 | 2158.50 |
F9 NW APARTMENT | 5522.50 | 5203.25 | 2292.25 |
F9 SE APARTMENT | 5733.50 | 4615.25 | 2081.75 |
F9 NE APARTMENT | 5494.25 | 5208.75 | 2223.25 |
F9 N1 APARTMENT | 5508.75 | 5069.50 | 2111.00 |
F9 N2 APARTMENT | 5506.25 | 5073.75 | 2109.25 |
F9 S1 APARTMENT | 5830.00 | 4294.00 | 1933.50 |
F9 S2 APARTMENT | 5827.00 | 4299.00 | 1934.00 |
T SW APARTMENT | 5870.50 | 5091.75 | 2603.75 |
T NW APARTMENT | 5672.50 | 5540.00 | 2734.50 |
T SE APARTMENT | 5857.75 | 5125.50 | 2591.75 |
T NE APARTMENT | 5639.50 | 5565.50 | 2712.00 |
T N1 APARTMENT | 5534.25 | 5454.25 | 2524.50 |
T N2 APARTMENT | 5533.50 | 5459.25 | 2527.00 |
T S1 APARTMENT | 5841.00 | 4858.75 | 2420.50 |
T S2 APARTMENT | 5842.00 | 4867.75 | 2425.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 6563.75 | 6795.25 | 3681.50 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 0.25 | 8.25 | 0.25 | 8.25 |
G NW APARTMENT | 0.00 | 3.00 | 0.00 | 3.00 |
OFFICE | 0.75 | 5.25 | 0.00 | 3.25 |
G NE APARTMENT | 0.00 | 8.50 | 0.00 | 8.50 |
G N1 APARTMENT | 3.00 | 11.50 | 3.00 | 11.50 |
G N2 APARTMENT | 3.00 | 11.50 | 3.00 | 11.50 |
G S1 APARTMENT | 2.25 | 214.75 | 2.25 | 214.75 |
G S2 APARTMENT | 1.00 | 179.25 | 1.00 | 179.25 |
F2 SW APARTMENT | 0.00 | 6.50 | 0.00 | 6.50 |
F2 NW APARTMENT | 0.00 | 2.00 | 0.00 | 2.00 |
F2 SE APARTMENT | 0.25 | 11.50 | 0.25 | 11.50 |
F2 NE APARTMENT | 0.00 | 2.00 | 0.00 | 2.00 |
F2 N1 APARTMENT | 2.00 | 9.00 | 2.00 | 9.00 |
F2 N2 APARTMENT | 1.75 | 9.25 | 1.75 | 9.25 |
F2 S1 APARTMENT | 2.00 | 207.50 | 2.00 | 207.50 |
F2 S2 APARTMENT | 1.50 | 190.25 | 1.50 | 190.25 |
F3 SW APARTMENT | 0.25 | 6.50 | 0.25 | 6.50 |
F3 NW APARTMENT | 0.00 | 2.25 | 0.00 | 2.25 |
F3 SE APARTMENT | 0.25 | 44.50 | 0.25 | 44.50 |
F3 NE APARTMENT | 0.00 | 4.00 | 0.00 | 4.00 |
F3 N1 APARTMENT | 3.00 | 14.75 | 3.00 | 14.75 |
F3 N2 APARTMENT | 2.75 | 15.50 | 2.75 | 15.50 |
F3 S1 APARTMENT | 1.75 | 213.75 | 1.75 | 213.75 |
F3 S2 APARTMENT | 2.25 | 209.00 | 2.25 | 209.00 |
F4 SW APARTMENT | 0.50 | 6.50 | 0.50 | 6.50 |
F4 NW APARTMENT | 0.00 | 2.00 | 0.00 | 2.00 |
F4 SE APARTMENT | 0.50 | 50.00 | 0.50 | 50.00 |
F4 NE APARTMENT | 0.00 | 3.75 | 0.00 | 3.75 |
F4 N1 APARTMENT | 2.00 | 16.25 | 2.00 | 16.25 |
F4 N2 APARTMENT | 1.00 | 16.50 | 1.00 | 16.50 |
F4 S1 APARTMENT | 0.25 | 206.75 | 0.25 | 206.75 |
F4 S2 APARTMENT | 1.50 | 203.25 | 1.50 | 203.25 |
M SW APARTMENT | 0.00 | 6.50 | 0.00 | 6.50 |
M NW APARTMENT | 0.00 | 2.50 | 0.00 | 2.50 |
M SE APARTMENT | 0.00 | 47.00 | 0.00 | 47.00 |
M NE APARTMENT | 0.00 | 4.25 | 0.00 | 4.25 |
M N1 APARTMENT | 2.00 | 16.75 | 2.00 | 16.75 |
M N2 APARTMENT | 1.00 | 17.75 | 1.00 | 17.75 |
M S1 APARTMENT | 1.00 | 199.25 | 1.00 | 199.25 |
M S2 APARTMENT | 1.25 | 197.50 | 1.25 | 197.50 |
F6 SW APARTMENT | 0.00 | 6.50 | 0.00 | 6.50 |
F6 NW APARTMENT | 0.00 | 3.00 | 0.00 | 3.00 |
F6 SE APARTMENT | 0.00 | 47.50 | 0.00 | 47.50 |
F6 NE APARTMENT | 0.00 | 4.25 | 0.00 | 4.25 |
F6 N1 APARTMENT | 1.25 | 18.50 | 1.25 | 18.50 |
F6 N2 APARTMENT | 1.50 | 19.50 | 1.50 | 19.50 |
F6 S1 APARTMENT | 1.25 | 193.50 | 1.25 | 193.50 |
F6 S2 APARTMENT | 1.00 | 189.75 | 1.00 | 189.75 |
F7 SW APARTMENT | 0.00 | 6.50 | 0.00 | 6.50 |
F7 NW APARTMENT | 0.00 | 3.25 | 0.00 | 3.25 |
F7 SE APARTMENT | 0.00 | 46.25 | 0.00 | 46.25 |
F7 NE APARTMENT | 0.00 | 4.75 | 0.00 | 4.75 |
F7 N1 APARTMENT | 0.75 | 19.75 | 0.75 | 19.75 |
F7 N2 APARTMENT | 0.25 | 21.00 | 0.25 | 21.00 |
F7 S1 APARTMENT | 1.50 | 186.75 | 1.50 | 186.75 |
F7 S2 APARTMENT | 2.00 | 182.25 | 2.00 | 182.25 |
F8 SW APARTMENT | 0.50 | 6.75 | 0.50 | 6.75 |
F8 NW APARTMENT | 0.00 | 3.50 | 0.00 | 3.50 |
F8 SE APARTMENT | 0.50 | 44.00 | 0.50 | 44.00 |
F8 NE APARTMENT | 0.00 | 6.25 | 0.00 | 6.25 |
F8 N1 APARTMENT | 2.00 | 21.50 | 2.00 | 21.50 |
F8 N2 APARTMENT | 2.00 | 22.00 | 2.00 | 22.00 |
F8 S1 APARTMENT | 0.50 | 176.00 | 0.50 | 176.00 |
F8 S2 APARTMENT | 0.75 | 173.25 | 0.75 | 173.25 |
F9 SW APARTMENT | 0.00 | 6.25 | 0.00 | 6.25 |
F9 NW APARTMENT | 0.00 | 3.75 | 0.00 | 3.75 |
F9 SE APARTMENT | 0.25 | 39.00 | 0.25 | 39.00 |
F9 NE APARTMENT | 0.00 | 7.50 | 0.00 | 7.50 |
F9 N1 APARTMENT | 1.50 | 18.75 | 1.50 | 18.75 |
F9 N2 APARTMENT | 1.50 | 20.25 | 1.50 | 20.25 |
F9 S1 APARTMENT | 0.00 | 147.00 | 0.00 | 147.00 |
F9 S2 APARTMENT | 1.25 | 143.00 | 1.25 | 143.00 |
T SW APARTMENT | 0.00 | 7.50 | 0.00 | 7.50 |
T NW APARTMENT | 0.00 | 3.75 | 0.00 | 3.75 |
T SE APARTMENT | 0.00 | 19.25 | 0.00 | 19.25 |
T NE APARTMENT | 0.00 | 2.75 | 0.00 | 2.75 |
T N1 APARTMENT | 0.00 | 3.00 | 0.00 | 3.00 |
T N2 APARTMENT | 0.00 | 3.00 | 0.00 | 3.00 |
T S1 APARTMENT | 0.00 | 34.00 | 0.00 | 34.00 |
T S2 APARTMENT | 0.25 | 34.75 | 0.25 | 34.75 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 48.00 | 315.00 | 47.25 | 313.50 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:57
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.151 | 0.000 | 0.386 |
G NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.151 | 0.000 | 0.359 |
OFFICE | 0.94 | 1.00 | 268.96 | 0.522 | 0.186 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.151 | 0.000 | 0.358 |
G N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.091 | 0.000 | 0.351 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.091 | 0.000 | 0.350 |
G S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.091 | 0.000 | 0.382 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.091 | 0.000 | 0.383 |
F2 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.217 | 0.000 | 0.458 |
F2 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.217 | 0.000 | 0.422 |
F2 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.217 | 0.000 | 0.460 |
F2 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.217 | 0.000 | 0.421 |
F2 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.131 | 0.000 | 0.417 |
F2 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.131 | 0.000 | 0.417 |
F2 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.131 | 0.000 | 0.456 |
F2 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.131 | 0.000 | 0.457 |
F3 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.257 | 0.000 | 0.514 |
F3 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.256 | 0.000 | 0.470 |
F3 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.257 | 0.000 | 0.513 |
F3 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.256 | 0.000 | 0.469 |
F3 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.155 | 0.000 | 0.466 |
F3 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.155 | 0.000 | 0.466 |
F3 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.155 | 0.000 | 0.512 |
F3 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.155 | 0.000 | 0.512 |
F4 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.287 | 0.000 | 0.538 |
F4 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.286 | 0.000 | 0.490 |
F4 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.287 | 0.000 | 0.537 |
F4 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.286 | 0.000 | 0.489 |
F4 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.173 | 0.000 | 0.486 |
F4 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.173 | 0.000 | 0.486 |
F4 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.173 | 0.000 | 0.537 |
F4 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.173 | 0.000 | 0.537 |
M SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.311 | 0.000 | 0.566 |
M NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.311 | 0.000 | 0.514 |
M SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.311 | 0.000 | 0.565 |
M NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.311 | 0.000 | 0.513 |
M N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.188 | 0.000 | 0.511 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.188 | 0.000 | 0.511 |
M S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.188 | 0.000 | 0.565 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.188 | 0.000 | 0.565 |
F6 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.333 | 0.000 | 0.590 |
F6 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.333 | 0.000 | 0.534 |
F6 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.333 | 0.000 | 0.589 |
F6 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.333 | 0.000 | 0.533 |
F6 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.201 | 0.000 | 0.531 |
F6 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.201 | 0.000 | 0.531 |
F6 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.201 | 0.000 | 0.589 |
F6 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.201 | 0.000 | 0.589 |
F7 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.352 | 0.000 | 0.611 |
F7 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.351 | 0.000 | 0.552 |
F7 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.352 | 0.000 | 0.610 |
F7 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.351 | 0.000 | 0.551 |
F7 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.212 | 0.000 | 0.549 |
F7 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.212 | 0.000 | 0.549 |
F7 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.212 | 0.000 | 0.610 |
F7 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.212 | 0.000 | 0.610 |
F8 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.369 | 0.000 | 0.632 |
F8 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.368 | 0.000 | 0.571 |
F8 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.369 | 0.000 | 0.632 |
F8 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.368 | 0.000 | 0.570 |
F8 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.222 | 0.000 | 0.568 |
F8 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.222 | 0.000 | 0.568 |
F8 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.222 | 0.000 | 0.631 |
F8 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.222 | 0.000 | 0.631 |
F9 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.384 | 0.000 | 0.654 |
F9 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.384 | 0.000 | 0.589 |
F9 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.384 | 0.000 | 0.653 |
F9 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.384 | 0.000 | 0.588 |
F9 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.232 | 0.000 | 0.586 |
F9 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.232 | 0.000 | 0.586 |
F9 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.232 | 0.000 | 0.652 |
F9 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.232 | 0.000 | 0.652 |
T SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.398 | 0.000 | 0.669 |
T NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.398 | 0.000 | 0.603 |
T SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.398 | 0.000 | 0.669 |
T NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.398 | 0.000 | 0.603 |
T N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.240 | 0.000 | 0.601 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.240 | 0.000 | 0.601 |
T S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.356 | 0.240 | 0.000 | 0.668 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.356 | 0.240 | 0.000 | 0.668 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.96 | 0.501 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F2 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F3 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F4 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F6 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F7 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F8 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
F9 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.341 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:57
Surfaces by ClassTotal | Outdoors | |
Wall | 420 | 140 |
Floor | 90 | 9 |
Roof | 90 | 9 |
Internal Mass | 80 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 140 | 140 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 80 |
Conditioned Zones | 80 |
Unconditioned Zones | 10 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 4156 |
Defaulted Fields | 814 |
Fields with Defaults | 11184 |
Autosized Fields | 1293 |
Autosizable Fields | 1630 |
Autocalculated Fields | 907 |
Autocalculatable Fields | 1710 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2015-09-09 19:11:57
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 3386.78 | 57747.05 | 08-JAN-04:00 | 189408.37 | 04-AUG-17:15 |
Electricity:Building | 1433.88 | 25760.85 | 01-JAN-03:15 | 70162.48 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity | 296.56 | 6715.87 | 01-JAN-00:15 | 14401.37 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 242.55 | 5824.91 | 01-JAN-00:15 | 11484.27 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 39.38 | 663.42 | 01-JAN-00:15 | 2934.49 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 29.88 | 469.18 | 01-JAN-00:15 | 2345.88 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F2 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F2 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F3 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F3 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F4 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F4 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:M SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M CORRIDOR | 32.88 | 1042.61 | 01-JAN-00:15 | 1042.61 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 32.88 | 1042.61 | 01-JAN-00:15 | 1042.61 | 01-JAN-00:15 |
Electricity:Zone:F6 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F6 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F7 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F7 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F8 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F8 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F9 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F9 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:T SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T CORRIDOR | 179.47 | 1701.70 | 01-JAN-00:15 | 10868.20 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 54.01 | 890.97 | 01-JAN-00:15 | 2917.11 | 01-JAN-19:15 |
InteriorEquipment:Electricity | 1137.32 | 19044.98 | 01-JAN-03:15 | 57142.09 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 1137.32 | 19044.98 | 01-JAN-03:15 | 57142.09 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 9.50 | 194.24 | 01-JAN-00:15 | 588.62 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T CORRIDOR | 163.03 | 1180.40 | 01-JAN-00:15 | 10346.90 | 01-JAN-07:15 |
Fans:Electricity | 659.86 | 20924.02 | 15-FEB-06:30 | 20924.02 | 01-JAN-00:15 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Electricity:HVAC | 1670.09 | 21585.27 | 08-JAN-04:00 | 113217.69 | 04-AUG-17:00 |
ElectricityProduced:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityProduced:HVAC | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricityProduced | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 3386.78 | 57747.05 | 08-JAN-04:00 | 189408.37 | 04-AUG-17:15 |
ElectricityPurchased:Plant | 3386.78 | 57747.05 | 08-JAN-04:00 | 189408.37 | 04-AUG-17:15 |
Cogeneration:ElectricityPurchased | 3386.78 | 57747.05 | 08-JAN-04:00 | 189408.37 | 04-AUG-17:15 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 3386.78 | 57747.05 | 08-JAN-04:00 | 189408.37 | 04-AUG-17:15 |
ElectricityNet:Plant | 3386.78 | 57747.05 | 08-JAN-04:00 | 189408.37 | 04-AUG-17:15 |
Cogeneration:ElectricityNet | 3386.78 | 57747.05 | 08-JAN-04:00 | 189408.37 | 04-AUG-17:15 |
ExteriorLights:Electricity | 162.86 | 0.00 | 01-JAN-07:30 | 10364.00 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 162.86 | 0.00 | 01-JAN-07:30 | 10364.00 | 01-JAN-00:15 |
General:Fans:Electricity | 659.86 | 20924.02 | 15-FEB-06:30 | 20924.02 | 01-JAN-00:15 |
Cooling:Electricity | 924.90 | 0.00 | 01-JAN-00:15 | 90298.51 | 04-AUG-17:00 |
Heating:Electricity | 49.16 | 0.00 | 01-JAN-12:15 | 55626.00 | 11-FEB-05:00 |
Electricity:Plant | 119.94 | 36.93 | 01-JAN-17:45 | 6106.79 | 03-JUN-17:00 |
HeatRejection:Electricity | 46.83 | 0.00 | 01-JAN-00:15 | 3653.19 | 03-JUN-17:00 |
Boiler Parasitic:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Pumps:Electricity | 73.12 | 36.93 | 01-JAN-17:45 | 2453.60 | 01-JAN-00:15 |
WIRED_LTG_ELECTRICITY | 0.44 | 0.00 | 01-JAN-00:15 | 21.60 | 01-JAN-19:30 |
WIRED_INT_EQUIP | 979.40 | 1018.50 | 01-JAN-00:15 | 10185.00 | 01-JAN-07:15 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 1059.39 | 2357.00 | 01-JAN-00:15 | 278005.55 | 11-FEB-06:45 |
Gas:Plant | 1059.39 | 2357.00 | 01-JAN-00:15 | 278005.55 | 11-FEB-06:45 |
WaterSystems:Gas | 918.44 | 2357.00 | 01-JAN-00:15 | 74846.98 | 28-JAN-08:00 |
Water Heater:WaterSystems:Gas | 918.44 | 2357.00 | 01-JAN-00:15 | 74846.98 | 28-JAN-08:00 |
Heating:Gas | 140.95 | 0.00 | 01-JAN-00:15 | 230535.48 | 11-FEB-05:00 |
Boiler:Heating:Gas | 140.95 | 0.00 | 01-JAN-00:15 | 230535.48 | 11-FEB-05:00 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
PlantLoopCoolingDemand:Facility | 4155.40 | 0.00 | 01-JAN-00:15 | 425267.42 | 04-AUG-17:45 |
PlantLoopCoolingDemand:HVAC | 4155.40 | 0.00 | 01-JAN-00:15 | 425267.42 | 04-AUG-17:45 |
CoolingCoils:PlantLoopCoolingDemand | 4155.40 | 0.00 | 01-JAN-00:15 | 425267.42 | 04-AUG-17:45 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 7171.27 | 0.00 | 01-JAN-02:15 | 0.00 | 02-AUG-17:15 |
Water:Plant | 7171.27 | 0.00 | 01-JAN-02:15 | 0.00 | 02-AUG-17:15 |
WaterSystems:Water | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:Water | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
MainsWater:Facility | 7171.27 | 0.00 | 01-JAN-02:15 | 0.00 | 02-AUG-17:15 |
MainsWater:Plant | 7171.27 | 0.00 | 01-JAN-02:15 | 0.00 | 02-AUG-17:15 |
WaterSystems:MainsWater | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:MainsWater | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
sub cat:WaterSystems:Water | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
sub cat:WaterSystems:MainsWater | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
HeatRejection:Water | 2392.76 | 0.00 | 01-JAN-00:15 | 0.00 | 01-AUG-16:00 |
HeatRejection:MainsWater | 2392.76 | 0.00 | 01-JAN-00:15 | 0.00 | 01-AUG-16:00 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 843.07 | 353.19 | 29-JUL-01:15 | 208871.39 | 11-FEB-07:00 |
PlantLoopHeatingDemand:Plant | 711.15 | 353.19 | 29-JUL-01:15 | 49706.72 | 25-JAN-08:00 |
WaterSystems:PlantLoopHeatingDemand | 711.15 | 353.19 | 29-JUL-01:15 | 49706.72 | 25-JAN-08:00 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 6135.92 | 5815.02 | 13-APR-03:00 | 582762.37 | 11-FEB-05:00 |
EnergyTransfer:Building | 1859.12 | 3734.30 | 01-MAR-22:15 | 211090.82 | 01-AUG-15:30 |
EnergyTransfer:Zone:G SW APARTMENT | 19.65 | 0.03 | 20-APR-23:30 | 3273.81 | 28-SEP-15:15 |
Heating:EnergyTransfer | 162.09 | 0.00 | 30-JAN-24:00 | 180765.22 | 11-FEB-04:00 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 2.36 | 0.00 | 01-JAN-08:15 | 1923.27 | 11-FEB-05:00 |
Cooling:EnergyTransfer | 1697.03 | 0.00 | 04-JAN-00:30 | 211090.82 | 01-AUG-15:30 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 17.29 | 0.00 | 01-JAN-00:15 | 3273.81 | 28-SEP-15:15 |
EnergyTransfer:Zone:G NW APARTMENT | 17.75 | 0.02 | 16-NOV-11:45 | 3054.30 | 01-AUG-17:30 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 3.52 | 0.00 | 01-JAN-18:00 | 2020.25 | 11-FEB-05:00 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 14.23 | 0.00 | 01-JAN-00:15 | 3054.30 | 01-AUG-17:30 |
EnergyTransfer:Zone:OFFICE | 28.85 | 0.02 | 25-OCT-23:30 | 4334.26 | 28-SEP-13:30 |
Heating:EnergyTransfer:Zone:OFFICE | 1.50 | 0.00 | 01-JAN-07:45 | 1842.47 | 11-FEB-07:00 |
Cooling:EnergyTransfer:Zone:OFFICE | 27.34 | 0.00 | 01-JAN-00:15 | 4334.26 | 28-SEP-13:30 |
EnergyTransfer:Zone:G NE APARTMENT | 17.39 | 0.01 | 20-MAY-23:15 | 2194.25 | 03-AUG-10:00 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 3.20 | 0.00 | 01-JAN-08:30 | 2037.41 | 11-FEB-05:00 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 14.19 | 0.00 | 01-JAN-00:15 | 2194.25 | 03-AUG-10:00 |
EnergyTransfer:Zone:G N1 APARTMENT | 11.87 | 0.01 | 06-APR-08:30 | 1536.24 | 01-AUG-17:15 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 1.58 | 0.00 | 01-JAN-10:15 | 1254.73 | 23-JAN-14:00 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 10.28 | 0.00 | 01-JAN-00:15 | 1536.24 | 01-AUG-17:15 |
EnergyTransfer:Zone:G N2 APARTMENT | 11.88 | 0.00 | 17-APR-00:45 | 1524.55 | 01-AUG-17:15 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 1.59 | 0.00 | 01-JAN-10:15 | 1250.80 | 23-JAN-14:00 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 10.29 | 0.00 | 01-JAN-00:15 | 1524.55 | 01-AUG-17:15 |
EnergyTransfer:Zone:G S1 APARTMENT | 14.25 | 0.01 | 17-APR-03:30 | 1954.22 | 28-OCT-13:30 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.64 | 0.00 | 01-JAN-00:15 | 970.25 | 11-FEB-05:00 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 13.61 | 0.00 | 01-JAN-02:45 | 1954.22 | 28-OCT-13:30 |
EnergyTransfer:Zone:G S2 APARTMENT | 14.58 | 0.00 | 06-DEC-23:00 | 2014.80 | 28-OCT-13:30 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.60 | 0.00 | 01-JAN-00:15 | 958.08 | 11-FEB-05:00 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 13.98 | 0.00 | 01-JAN-03:00 | 2014.80 | 28-OCT-13:30 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F2 SW APARTMENT | 26.71 | 0.02 | 26-JAN-00:15 | 3818.44 | 28-SEP-14:45 |
Heating:EnergyTransfer:Zone:F2 SW APARTMENT | 1.62 | 0.00 | 01-JAN-00:15 | 2093.67 | 11-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT | 25.09 | 0.00 | 01-JAN-04:15 | 3818.44 | 28-SEP-14:45 |
EnergyTransfer:Zone:F2 NW APARTMENT | 23.55 | 0.01 | 09-FEB-07:45 | 3497.55 | 01-AUG-16:15 |
Heating:EnergyTransfer:Zone:F2 NW APARTMENT | 2.87 | 0.00 | 01-JAN-10:00 | 2326.03 | 11-FEB-04:15 |
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT | 20.68 | 0.00 | 01-JAN-00:15 | 3497.55 | 01-AUG-16:15 |
EnergyTransfer:Zone:F2 SE APARTMENT | 28.22 | 0.00 | 22-FEB-03:45 | 3452.24 | 28-SEP-13:45 |
Heating:EnergyTransfer:Zone:F2 SE APARTMENT | 1.25 | 0.00 | 01-JAN-00:15 | 2012.98 | 11-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT | 26.97 | 0.00 | 01-JAN-04:30 | 3452.24 | 28-SEP-13:45 |
EnergyTransfer:Zone:F2 NE APARTMENT | 23.30 | 0.01 | 23-JAN-11:30 | 2630.82 | 03-AUG-10:00 |
Heating:EnergyTransfer:Zone:F2 NE APARTMENT | 2.58 | 0.00 | 01-JAN-08:00 | 2351.84 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT | 20.73 | 0.00 | 01-JAN-00:15 | 2630.82 | 03-AUG-10:00 |
EnergyTransfer:Zone:F2 N1 APARTMENT | 16.92 | 0.00 | 20-JAN-19:15 | 1844.35 | 01-AUG-17:45 |
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT | 0.94 | 0.00 | 01-JAN-07:30 | 1423.61 | 23-JAN-14:00 |
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT | 15.98 | 0.00 | 01-JAN-00:15 | 1844.35 | 01-AUG-17:45 |
EnergyTransfer:Zone:F2 N2 APARTMENT | 16.93 | 0.04 | 20-DEC-17:30 | 1834.78 | 01-AUG-17:45 |
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT | 0.94 | 0.00 | 01-JAN-07:30 | 1418.81 | 23-JAN-14:00 |
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT | 15.99 | 0.00 | 01-JAN-00:15 | 1834.78 | 01-AUG-17:45 |
EnergyTransfer:Zone:F2 S1 APARTMENT | 20.89 | 0.00 | 09-APR-04:30 | 2388.14 | 28-OCT-13:30 |
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT | 0.30 | 0.00 | 01-JAN-00:15 | 888.70 | 11-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT | 20.59 | 0.00 | 03-JAN-08:00 | 2388.14 | 28-OCT-13:30 |
EnergyTransfer:Zone:F2 S2 APARTMENT | 21.04 | 0.09 | 25-FEB-19:30 | 2410.23 | 28-OCT-13:30 |
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT | 0.29 | 0.00 | 01-JAN-00:15 | 878.30 | 11-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT | 20.75 | 0.00 | 03-JAN-08:00 | 2410.23 | 28-OCT-13:30 |
EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F3 SW APARTMENT | 27.84 | 0.03 | 17-JAN-11:00 | 3820.56 | 28-SEP-14:45 |
Heating:EnergyTransfer:Zone:F3 SW APARTMENT | 1.59 | 0.00 | 01-JAN-00:15 | 2322.04 | 11-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT | 26.25 | 0.00 | 01-JAN-12:45 | 3820.56 | 28-SEP-14:45 |
EnergyTransfer:Zone:F3 NW APARTMENT | 24.70 | 0.01 | 15-NOV-01:45 | 3549.37 | 01-AUG-16:15 |
Heating:EnergyTransfer:Zone:F3 NW APARTMENT | 2.85 | 0.00 | 01-JAN-09:45 | 2586.56 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT | 21.85 | 0.00 | 01-JAN-00:15 | 3549.37 | 01-AUG-16:15 |
EnergyTransfer:Zone:F3 SE APARTMENT | 27.95 | 0.03 | 03-JAN-13:15 | 3301.79 | 29-OCT-13:45 |
Heating:EnergyTransfer:Zone:F3 SE APARTMENT | 1.38 | 0.00 | 01-JAN-00:15 | 2319.35 | 11-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT | 26.57 | 0.00 | 01-JAN-12:45 | 3301.79 | 29-OCT-13:45 |
EnergyTransfer:Zone:F3 NE APARTMENT | 24.47 | 0.00 | 28-FEB-04:15 | 2656.38 | 01-JUL-10:00 |
Heating:EnergyTransfer:Zone:F3 NE APARTMENT | 2.58 | 0.00 | 01-JAN-07:45 | 2614.63 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT | 21.90 | 0.00 | 01-JAN-00:15 | 2656.38 | 01-JUL-10:00 |
EnergyTransfer:Zone:F3 N1 APARTMENT | 18.18 | 0.00 | 29-JAN-03:00 | 1887.15 | 01-AUG-17:45 |
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT | 0.87 | 0.00 | 01-JAN-00:15 | 1580.91 | 23-JAN-14:00 |
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT | 17.31 | 0.00 | 01-JAN-00:45 | 1887.15 | 01-AUG-17:45 |
EnergyTransfer:Zone:F3 N2 APARTMENT | 18.18 | 0.06 | 29-JAN-02:45 | 1877.64 | 01-AUG-17:45 |
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT | 0.88 | 0.00 | 01-JAN-00:15 | 1575.79 | 23-JAN-14:00 |
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT | 17.31 | 0.00 | 01-JAN-01:00 | 1877.64 | 01-AUG-17:45 |
EnergyTransfer:Zone:F3 S1 APARTMENT | 22.32 | 0.03 | 26-FEB-08:00 | 2476.44 | 13-NOV-13:30 |
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT | 0.27 | 0.00 | 01-JAN-00:15 | 974.19 | 11-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT | 22.05 | 0.00 | 03-JAN-08:00 | 2476.44 | 13-NOV-13:30 |
EnergyTransfer:Zone:F3 S2 APARTMENT | 22.35 | 0.01 | 10-APR-19:45 | 2482.26 | 13-NOV-13:00 |
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT | 0.27 | 0.00 | 01-JAN-00:15 | 974.10 | 11-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT | 22.09 | 0.00 | 03-JAN-08:00 | 2482.26 | 13-NOV-13:00 |
EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F4 SW APARTMENT | 28.08 | 0.00 | 01-DEC-01:15 | 3816.26 | 31-OCT-15:15 |
Heating:EnergyTransfer:Zone:F4 SW APARTMENT | 1.72 | 0.00 | 01-JAN-00:15 | 2552.59 | 11-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT | 26.36 | 0.00 | 01-JAN-12:45 | 3816.26 | 31-OCT-15:15 |
EnergyTransfer:Zone:F4 NW APARTMENT | 25.09 | 0.02 | 11-DEC-11:15 | 3588.66 | 01-AUG-16:15 |
Heating:EnergyTransfer:Zone:F4 NW APARTMENT | 3.00 | 0.00 | 01-JAN-09:45 | 2827.57 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT | 22.09 | 0.00 | 01-JAN-00:15 | 3588.66 | 01-AUG-16:15 |
EnergyTransfer:Zone:F4 SE APARTMENT | 28.01 | 0.01 | 16-FEB-01:45 | 3306.73 | 29-OCT-13:45 |
Heating:EnergyTransfer:Zone:F4 SE APARTMENT | 1.54 | 0.00 | 01-JAN-00:15 | 2568.35 | 11-FEB-04:45 |
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT | 26.47 | 0.00 | 01-JAN-12:45 | 3306.73 | 29-OCT-13:45 |
EnergyTransfer:Zone:F4 NE APARTMENT | 24.85 | 0.00 | 16-OCT-01:30 | 2850.89 | 11-FEB-04:00 |
Heating:EnergyTransfer:Zone:F4 NE APARTMENT | 2.71 | 0.00 | 01-JAN-07:45 | 2850.89 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT | 22.14 | 0.00 | 01-JAN-00:15 | 2707.86 | 04-AUG-14:00 |
EnergyTransfer:Zone:F4 N1 APARTMENT | 18.53 | 0.01 | 03-OCT-19:30 | 1917.18 | 01-AUG-17:45 |
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT | 0.90 | 0.00 | 01-JAN-00:15 | 1684.87 | 23-JAN-14:15 |
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT | 17.64 | 0.00 | 01-JAN-01:15 | 1917.18 | 01-AUG-17:45 |
EnergyTransfer:Zone:F4 N2 APARTMENT | 18.54 | 0.02 | 20-FEB-09:00 | 1907.72 | 01-AUG-17:45 |
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT | 0.90 | 0.00 | 01-JAN-00:15 | 1680.43 | 23-JAN-14:15 |
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT | 17.64 | 0.00 | 01-JAN-01:30 | 1907.72 | 01-AUG-17:45 |
EnergyTransfer:Zone:F4 S1 APARTMENT | 22.59 | 0.02 | 19-MAY-07:45 | 2510.75 | 13-NOV-13:30 |
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT | 0.29 | 0.00 | 01-JAN-00:15 | 1105.99 | 11-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT | 22.30 | 0.00 | 04-JAN-00:30 | 2510.75 | 13-NOV-13:30 |
EnergyTransfer:Zone:F4 S2 APARTMENT | 22.61 | 0.01 | 19-MAY-07:45 | 2513.63 | 13-NOV-13:30 |
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT | 0.30 | 0.00 | 01-JAN-00:15 | 1110.02 | 11-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT | 22.31 | 0.00 | 04-JAN-00:30 | 2513.63 | 13-NOV-13:30 |
EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M SW APARTMENT | 28.51 | 0.02 | 14-JAN-09:00 | 3832.00 | 28-SEP-14:45 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 1.87 | 0.00 | 01-JAN-00:15 | 2741.77 | 11-FEB-04:15 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 26.64 | 0.00 | 01-JAN-12:45 | 3832.00 | 28-SEP-14:45 |
EnergyTransfer:Zone:M NW APARTMENT | 25.68 | 0.01 | 27-MAR-18:45 | 3642.29 | 01-AUG-16:15 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 3.17 | 0.00 | 01-JAN-09:45 | 3020.01 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 22.51 | 0.00 | 01-JAN-00:15 | 3642.29 | 01-AUG-16:15 |
EnergyTransfer:Zone:M SE APARTMENT | 28.40 | 0.09 | 03-JAN-04:15 | 3343.61 | 29-OCT-13:30 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 1.68 | 0.00 | 01-JAN-00:15 | 2761.93 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 26.72 | 0.00 | 01-JAN-12:45 | 3343.61 | 29-OCT-13:30 |
EnergyTransfer:Zone:M NE APARTMENT | 25.42 | 0.01 | 17-JAN-03:30 | 3038.98 | 11-FEB-04:00 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 2.87 | 0.00 | 01-JAN-07:45 | 3038.98 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 22.55 | 0.00 | 01-JAN-00:15 | 2751.62 | 04-AUG-14:00 |
EnergyTransfer:Zone:M N1 APARTMENT | 19.05 | 0.01 | 26-FEB-07:30 | 1964.03 | 01-AUG-17:45 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.96 | 0.00 | 01-JAN-00:15 | 1805.50 | 23-JAN-14:15 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 18.09 | 0.00 | 01-JAN-02:15 | 1964.03 | 01-AUG-17:45 |
EnergyTransfer:Zone:M N2 APARTMENT | 19.05 | 0.00 | 22-NOV-19:00 | 1954.61 | 01-AUG-17:45 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.96 | 0.00 | 01-JAN-00:15 | 1801.70 | 23-JAN-14:15 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 18.09 | 0.00 | 01-JAN-02:15 | 1954.61 | 01-AUG-17:45 |
EnergyTransfer:Zone:M S1 APARTMENT | 22.98 | 0.08 | 23-NOV-08:45 | 2530.18 | 28-OCT-13:30 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.34 | 0.00 | 01-JAN-00:15 | 1213.11 | 11-FEB-05:00 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 22.64 | 0.00 | 01-JAN-13:30 | 2530.18 | 28-OCT-13:30 |
EnergyTransfer:Zone:M S2 APARTMENT | 22.98 | 0.00 | 16-JAN-15:00 | 2536.35 | 28-OCT-13:30 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.34 | 0.00 | 01-JAN-00:15 | 1218.09 | 11-FEB-05:00 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 22.64 | 0.00 | 01-JAN-13:30 | 2536.35 | 28-OCT-13:30 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F6 SW APARTMENT | 27.96 | 0.03 | 12-DEC-20:15 | 3789.91 | 28-SEP-14:45 |
Heating:EnergyTransfer:Zone:F6 SW APARTMENT | 2.15 | 0.00 | 01-JAN-00:15 | 2962.19 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT | 25.82 | 0.00 | 01-JAN-12:45 | 3789.91 | 28-SEP-14:45 |
EnergyTransfer:Zone:F6 NW APARTMENT | 25.44 | 0.03 | 03-DEC-21:45 | 3632.67 | 01-AUG-16:15 |
Heating:EnergyTransfer:Zone:F6 NW APARTMENT | 3.55 | 0.00 | 01-JAN-09:45 | 3232.77 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT | 21.89 | 0.00 | 01-JAN-00:15 | 3632.67 | 01-AUG-16:15 |
EnergyTransfer:Zone:F6 SE APARTMENT | 27.84 | 0.03 | 03-MAR-13:30 | 3319.30 | 29-OCT-13:30 |
Heating:EnergyTransfer:Zone:F6 SE APARTMENT | 1.95 | 0.00 | 01-JAN-00:15 | 2979.35 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT | 25.89 | 0.00 | 01-JAN-06:00 | 3319.30 | 29-OCT-13:30 |
EnergyTransfer:Zone:F6 NE APARTMENT | 25.17 | 0.02 | 26-DEC-11:30 | 3245.35 | 11-FEB-04:00 |
Heating:EnergyTransfer:Zone:F6 NE APARTMENT | 3.25 | 0.00 | 01-JAN-07:45 | 3245.35 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT | 21.92 | 0.00 | 01-JAN-00:15 | 2740.03 | 02-AUG-16:15 |
EnergyTransfer:Zone:F6 N1 APARTMENT | 18.61 | 0.05 | 28-JAN-24:00 | 1972.62 | 23-JAN-14:15 |
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT | 1.16 | 0.00 | 01-JAN-00:15 | 1972.62 | 23-JAN-14:15 |
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT | 17.45 | 0.00 | 01-JAN-01:15 | 1947.36 | 01-AUG-17:45 |
EnergyTransfer:Zone:F6 N2 APARTMENT | 18.62 | 0.00 | 27-JAN-02:30 | 1969.19 | 23-JAN-14:15 |
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT | 1.17 | 0.00 | 01-JAN-00:15 | 1969.19 | 23-JAN-14:15 |
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT | 17.45 | 0.00 | 01-JAN-01:15 | 1938.03 | 01-AUG-17:45 |
EnergyTransfer:Zone:F6 S1 APARTMENT | 22.23 | 0.04 | 09-MAR-10:45 | 2510.22 | 28-OCT-13:30 |
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT | 0.43 | 0.00 | 01-JAN-00:15 | 1362.98 | 11-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT | 21.80 | 0.00 | 01-JAN-13:30 | 2510.22 | 28-OCT-13:30 |
EnergyTransfer:Zone:F6 S2 APARTMENT | 22.23 | 0.00 | 01-JAN-15:00 | 2516.29 | 28-OCT-13:30 |
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT | 0.44 | 0.00 | 01-JAN-00:15 | 1367.84 | 11-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT | 21.80 | 0.00 | 01-JAN-13:30 | 2516.29 | 28-OCT-13:30 |
EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F7 SW APARTMENT | 27.79 | 0.00 | 13-JAN-14:30 | 3769.99 | 28-SEP-14:45 |
Heating:EnergyTransfer:Zone:F7 SW APARTMENT | 2.39 | 0.00 | 01-JAN-00:15 | 3145.12 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT | 25.40 | 0.00 | 01-JAN-05:45 | 3769.99 | 28-SEP-14:45 |
EnergyTransfer:Zone:F7 NW APARTMENT | 25.50 | 0.01 | 04-MAR-21:15 | 3642.39 | 01-AUG-16:15 |
Heating:EnergyTransfer:Zone:F7 NW APARTMENT | 3.87 | 0.00 | 01-JAN-10:00 | 3407.82 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT | 21.63 | 0.00 | 01-JAN-00:15 | 3642.39 | 01-AUG-16:15 |
EnergyTransfer:Zone:F7 SE APARTMENT | 27.65 | 0.01 | 03-APR-01:45 | 3309.50 | 29-OCT-13:15 |
Heating:EnergyTransfer:Zone:F7 SE APARTMENT | 2.18 | 0.00 | 01-JAN-00:15 | 3158.53 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT | 25.47 | 0.00 | 01-JAN-04:45 | 3309.50 | 29-OCT-13:15 |
EnergyTransfer:Zone:F7 NE APARTMENT | 25.21 | 0.07 | 14-APR-14:15 | 3415.81 | 11-FEB-04:00 |
Heating:EnergyTransfer:Zone:F7 NE APARTMENT | 3.56 | 0.00 | 01-JAN-07:45 | 3415.81 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT | 21.65 | 0.00 | 01-JAN-00:15 | 2756.43 | 02-AUG-16:15 |
EnergyTransfer:Zone:F7 N1 APARTMENT | 18.51 | 0.08 | 25-NOV-02:30 | 2094.58 | 23-JAN-14:15 |
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT | 1.33 | 0.00 | 01-JAN-00:15 | 2094.58 | 23-JAN-14:15 |
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT | 17.18 | 0.00 | 01-JAN-01:15 | 1951.50 | 01-AUG-17:45 |
EnergyTransfer:Zone:F7 N2 APARTMENT | 18.52 | 0.02 | 13-DEC-03:45 | 2091.72 | 23-JAN-14:15 |
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT | 1.34 | 0.00 | 01-JAN-00:15 | 2091.72 | 23-JAN-14:15 |
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT | 17.18 | 0.00 | 01-JAN-00:45 | 1942.24 | 01-AUG-17:45 |
EnergyTransfer:Zone:F7 S1 APARTMENT | 21.89 | 0.05 | 03-DEC-15:00 | 2511.93 | 28-OCT-13:30 |
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT | 0.53 | 0.00 | 01-JAN-00:15 | 1481.91 | 11-FEB-05:00 |
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT | 21.37 | 0.00 | 01-JAN-12:45 | 2511.93 | 28-OCT-13:30 |
EnergyTransfer:Zone:F7 S2 APARTMENT | 21.90 | 0.02 | 06-APR-08:00 | 2517.95 | 28-OCT-13:30 |
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT | 0.53 | 0.00 | 01-JAN-00:15 | 1494.90 | 16-MAR-13:15 |
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT | 21.37 | 0.00 | 01-JAN-12:45 | 2517.95 | 28-OCT-13:30 |
EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F8 SW APARTMENT | 27.83 | 0.00 | 18-OCT-00:15 | 3761.23 | 28-SEP-14:45 |
Heating:EnergyTransfer:Zone:F8 SW APARTMENT | 2.62 | 0.00 | 01-JAN-00:15 | 3298.20 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT | 25.21 | 0.00 | 01-JAN-04:45 | 3761.23 | 28-SEP-14:45 |
EnergyTransfer:Zone:F8 NW APARTMENT | 25.75 | 0.08 | 28-JAN-00:45 | 3663.15 | 01-AUG-16:15 |
Heating:EnergyTransfer:Zone:F8 NW APARTMENT | 4.17 | 0.00 | 01-JAN-10:00 | 3555.25 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT | 21.58 | 0.00 | 01-JAN-00:15 | 3663.15 | 01-AUG-16:15 |
EnergyTransfer:Zone:F8 SE APARTMENT | 27.68 | 0.03 | 18-FEB-06:00 | 3308.83 | 11-FEB-04:00 |
Heating:EnergyTransfer:Zone:F8 SE APARTMENT | 2.41 | 0.00 | 01-JAN-00:15 | 3308.83 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT | 25.27 | 0.00 | 01-JAN-04:00 | 3304.30 | 29-OCT-12:45 |
EnergyTransfer:Zone:F8 NE APARTMENT | 25.44 | 0.01 | 07-JAN-02:45 | 3560.24 | 11-FEB-04:00 |
Heating:EnergyTransfer:Zone:F8 NE APARTMENT | 3.86 | 0.00 | 01-JAN-07:45 | 3560.24 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT | 21.59 | 0.00 | 01-JAN-00:15 | 2783.46 | 02-AUG-16:15 |
EnergyTransfer:Zone:F8 N1 APARTMENT | 18.63 | 0.13 | 10-APR-20:45 | 2209.67 | 23-JAN-14:15 |
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT | 1.51 | 0.00 | 01-JAN-00:15 | 2209.67 | 23-JAN-14:15 |
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT | 17.12 | 0.00 | 01-JAN-00:30 | 1969.89 | 01-AUG-17:45 |
EnergyTransfer:Zone:F8 N2 APARTMENT | 18.63 | 0.01 | 23-MAR-23:30 | 2206.50 | 23-JAN-14:15 |
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT | 1.51 | 0.00 | 01-JAN-00:15 | 2206.50 | 23-JAN-14:15 |
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT | 17.12 | 0.00 | 01-JAN-00:30 | 1960.68 | 01-AUG-17:45 |
EnergyTransfer:Zone:F8 S1 APARTMENT | 21.78 | 0.07 | 17-NOV-21:30 | 2527.83 | 28-OCT-13:30 |
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT | 0.62 | 0.00 | 01-JAN-00:15 | 1674.39 | 16-MAR-13:15 |
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT | 21.16 | 0.00 | 01-JAN-12:45 | 2527.83 | 28-OCT-13:30 |
EnergyTransfer:Zone:F8 S2 APARTMENT | 21.79 | 0.00 | 22-NOV-19:00 | 2533.81 | 28-OCT-13:30 |
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT | 0.63 | 0.00 | 01-JAN-00:15 | 1689.03 | 16-MAR-13:15 |
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT | 21.16 | 0.00 | 01-JAN-12:45 | 2533.81 | 28-OCT-13:30 |
EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F9 SW APARTMENT | 28.60 | 0.03 | 13-MAR-01:45 | 3865.03 | 01-AUG-15:30 |
Heating:EnergyTransfer:Zone:F9 SW APARTMENT | 3.02 | 0.00 | 01-JAN-00:15 | 3468.73 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT | 25.59 | 0.00 | 01-JAN-03:30 | 3865.03 | 01-AUG-15:30 |
EnergyTransfer:Zone:F9 NW APARTMENT | 26.77 | 0.00 | 15-NOV-02:15 | 3769.66 | 01-AUG-16:15 |
Heating:EnergyTransfer:Zone:F9 NW APARTMENT | 4.67 | 0.00 | 04-JAN-16:30 | 3711.77 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT | 22.11 | 0.00 | 01-JAN-00:15 | 3769.66 | 01-AUG-16:15 |
EnergyTransfer:Zone:F9 SE APARTMENT | 28.40 | 0.01 | 11-APR-22:45 | 3477.34 | 11-FEB-04:00 |
Heating:EnergyTransfer:Zone:F9 SE APARTMENT | 2.76 | 0.00 | 01-JAN-00:15 | 3477.34 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT | 25.64 | 0.00 | 01-JAN-03:00 | 3353.20 | 28-SEP-13:30 |
EnergyTransfer:Zone:F9 NE APARTMENT | 26.40 | 0.07 | 17-OCT-17:15 | 3713.04 | 11-FEB-04:00 |
Heating:EnergyTransfer:Zone:F9 NE APARTMENT | 4.30 | 0.00 | 01-JAN-08:00 | 3713.04 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT | 22.10 | 0.00 | 01-JAN-00:15 | 2899.34 | 02-AUG-16:15 |
EnergyTransfer:Zone:F9 N1 APARTMENT | 19.39 | 0.07 | 01-APR-03:30 | 2344.77 | 23-JAN-14:15 |
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT | 1.82 | 0.00 | 01-JAN-07:30 | 2344.77 | 23-JAN-14:15 |
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT | 17.56 | 0.00 | 01-JAN-00:15 | 2082.77 | 01-AUG-17:45 |
EnergyTransfer:Zone:F9 N2 APARTMENT | 19.39 | 0.04 | 17-MAR-05:15 | 2340.56 | 23-JAN-14:15 |
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT | 1.83 | 0.00 | 01-JAN-07:30 | 2340.56 | 23-JAN-14:15 |
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT | 17.56 | 0.00 | 01-JAN-00:15 | 2073.51 | 01-AUG-17:45 |
EnergyTransfer:Zone:F9 S1 APARTMENT | 22.25 | 0.11 | 03-OCT-20:00 | 2612.19 | 28-OCT-13:30 |
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT | 0.80 | 0.00 | 01-JAN-00:15 | 1905.14 | 16-MAR-13:15 |
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT | 21.45 | 0.00 | 01-JAN-12:45 | 2612.19 | 28-OCT-13:30 |
EnergyTransfer:Zone:F9 S2 APARTMENT | 22.26 | 0.02 | 05-SEP-06:00 | 2618.04 | 28-OCT-13:30 |
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT | 0.81 | 0.00 | 01-JAN-00:15 | 1918.71 | 16-MAR-13:15 |
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT | 21.45 | 0.00 | 01-JAN-12:45 | 2618.04 | 28-OCT-13:30 |
EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:T SW APARTMENT | 33.21 | 0.01 | 23-NOV-19:15 | 4759.39 | 01-AUG-15:15 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 5.48 | 0.00 | 01-JAN-08:45 | 4418.48 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 27.74 | 0.00 | 01-JAN-00:15 | 4759.39 | 01-AUG-15:15 |
EnergyTransfer:Zone:T NW APARTMENT | 31.28 | 0.08 | 28-FEB-10:15 | 4604.74 | 01-AUG-16:15 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 7.04 | 0.00 | 27-JAN-15:30 | 4591.66 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 24.24 | 0.00 | 01-JAN-00:15 | 4604.74 | 01-AUG-16:15 |
EnergyTransfer:Zone:T SE APARTMENT | 32.59 | 0.02 | 01-FEB-09:00 | 4405.91 | 11-FEB-04:00 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 5.04 | 0.00 | 01-JAN-08:00 | 4405.91 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 27.55 | 0.00 | 01-JAN-00:15 | 4082.63 | 28-SEP-13:30 |
EnergyTransfer:Zone:T NE APARTMENT | 30.46 | 0.04 | 26-DEC-18:45 | 4581.75 | 11-FEB-04:00 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 6.46 | 0.00 | 01-JAN-09:15 | 4581.75 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 24.00 | 0.00 | 01-JAN-00:15 | 3594.84 | 02-AUG-16:15 |
EnergyTransfer:Zone:T N1 APARTMENT | 22.51 | 0.00 | 16-FEB-01:45 | 2755.26 | 02-AUG-15:15 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 3.27 | 0.00 | 01-JAN-10:00 | 2737.05 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 19.24 | 0.00 | 01-JAN-00:15 | 2755.26 | 02-AUG-15:15 |
EnergyTransfer:Zone:T N2 APARTMENT | 22.53 | 0.05 | 09-SEP-05:00 | 2751.96 | 02-AUG-15:30 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 3.28 | 0.00 | 01-JAN-09:45 | 2739.75 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 19.24 | 0.00 | 01-JAN-00:15 | 2751.96 | 02-AUG-15:30 |
EnergyTransfer:Zone:T S1 APARTMENT | 25.16 | 0.04 | 29-OCT-03:30 | 3417.56 | 28-OCT-13:30 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 2.17 | 0.00 | 01-JAN-00:15 | 2556.51 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 22.98 | 0.00 | 01-JAN-00:30 | 3417.56 | 28-OCT-13:30 |
EnergyTransfer:Zone:T S2 APARTMENT | 25.17 | 0.00 | 16-OCT-01:45 | 3416.46 | 28-OCT-13:30 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 2.19 | 0.00 | 01-JAN-00:15 | 2558.66 | 11-FEB-04:00 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 22.99 | 0.00 | 01-JAN-00:30 | 3416.46 | 28-OCT-13:30 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Plant | 815.95 | 353.19 | 29-JUL-01:15 | 204219.05 | 11-FEB-07:00 |
WaterSystems:EnergyTransfer | 711.15 | 353.19 | 29-JUL-01:15 | 49701.63 | 25-JAN-08:00 |
sub cat:WaterSystems:EnergyTransfer | 711.15 | 353.19 | 29-JUL-01:15 | 49701.63 | 25-JAN-08:00 |
EnergyTransfer:HVAC | 3460.85 | 0.00 | 01-JAN-17:45 | 338241.33 | 07-JUL-09:45 |
CoolingCoils:EnergyTransfer | 3288.21 | 0.00 | 01-JAN-00:15 | 338241.33 | 07-JUL-09:45 |
HeatingCoils:EnergyTransfer | 172.65 | 0.00 | 01-JAN-12:15 | 227771.13 | 11-FEB-05:00 |
PlantLoopHeatingDemand:HVAC | 131.92 | 0.00 | 01-JAN-12:15 | 175212.49 | 11-FEB-05:00 |
HeatingCoils:PlantLoopHeatingDemand | 131.92 | 0.00 | 01-JAN-12:15 | 175212.49 | 11-FEB-05:00 |
Boilers:EnergyTransfer | 104.80 | 0.00 | 01-JAN-00:15 | 172901.61 | 11-FEB-05:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:57
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 2.358 | -17.294 | 0.000 | 0.000 | 3.697 | 1.087 | 12.213 | 20.441 | 0.000 | 0.926 | 0.000 | 0.000 | -6.804 | 0.000 | -5.195 | -11.428 |
G NW APARTMENT | 3.519 | -14.229 | 0.000 | 0.000 | 3.717 | 1.087 | 12.213 | 13.538 | 0.000 | 0.907 | 0.000 | 0.000 | -6.912 | 0.000 | -4.677 | -9.163 |
OFFICE | 1.503 | -27.341 | 0.000 | 0.000 | 0.506 | 29.882 | 9.495 | 19.946 | 0.000 | 0.654 | 0.000 | 0.000 | -6.929 | 0.000 | -2.075 | -25.642 |
G NE APARTMENT | 3.198 | -14.193 | 0.000 | 0.000 | 3.728 | 1.087 | 12.213 | 13.232 | 0.000 | 0.907 | 0.000 | 0.000 | -6.588 | 0.000 | -4.621 | -8.962 |
G N1 APARTMENT | 1.582 | -10.284 | 0.000 | 0.000 | 3.731 | 1.087 | 12.213 | 5.885 | 0.000 | 0.653 | 0.000 | 0.000 | -4.192 | 0.000 | -3.645 | -7.029 |
G N2 APARTMENT | 1.585 | -10.290 | 0.000 | 0.000 | 3.731 | 1.087 | 12.213 | 5.885 | 0.000 | 0.652 | 0.000 | 0.000 | -4.189 | 0.000 | -3.642 | -7.032 |
G S1 APARTMENT | 0.637 | -13.608 | 0.000 | 0.000 | 3.698 | 1.087 | 12.213 | 12.863 | 0.000 | 0.662 | 0.000 | 0.000 | -4.095 | 0.000 | -4.239 | -9.217 |
G S2 APARTMENT | 0.604 | -13.976 | 0.000 | 0.000 | 3.694 | 1.087 | 12.213 | 12.844 | 0.000 | 0.663 | 0.000 | 0.000 | -4.113 | 0.000 | -4.290 | -8.724 |
F2 SW APARTMENT | 1.618 | -25.091 | 0.000 | 0.000 | 3.640 | 1.087 | 12.213 | 19.400 | 0.000 | 1.261 | 0.329 | 0.000 | -7.504 | 0.000 | -6.952 | -0.000 |
F2 NW APARTMENT | 2.870 | -20.681 | 0.000 | 0.000 | 3.675 | 1.087 | 12.213 | 12.812 | 0.000 | 1.229 | 0.663 | 0.000 | -7.583 | 0.000 | -6.285 | -0.000 |
F2 SE APARTMENT | 1.253 | -26.967 | 0.000 | 0.000 | 3.635 | 1.087 | 12.213 | 19.157 | 0.000 | 1.261 | 2.841 | 0.000 | -7.423 | 0.000 | -7.055 | -0.000 |
F2 NE APARTMENT | 2.577 | -20.725 | 0.000 | 0.000 | 3.687 | 1.087 | 12.213 | 12.505 | 0.000 | 1.229 | 0.853 | 0.000 | -7.218 | 0.000 | -6.208 | -0.000 |
F2 N1 APARTMENT | 0.939 | -15.985 | 0.000 | 0.000 | 3.680 | 1.087 | 12.213 | 5.501 | 0.000 | 0.858 | 1.309 | 0.000 | -4.668 | 0.000 | -4.934 | -0.000 |
F2 N2 APARTMENT | 0.944 | -15.987 | 0.000 | 0.000 | 3.681 | 1.087 | 12.213 | 5.501 | 0.000 | 0.858 | 1.297 | 0.000 | -4.664 | 0.000 | -4.930 | -0.000 |
F2 S1 APARTMENT | 0.296 | -20.593 | 0.000 | 0.000 | 3.631 | 1.087 | 12.213 | 12.183 | 0.000 | 0.881 | 0.520 | 0.000 | -4.535 | 0.000 | -5.683 | -0.000 |
F2 S2 APARTMENT | 0.291 | -20.747 | 0.000 | 0.000 | 3.630 | 1.087 | 12.213 | 12.178 | 0.000 | 0.882 | 0.709 | 0.000 | -4.542 | 0.000 | -5.700 | -0.000 |
F3 SW APARTMENT | 1.594 | -26.249 | 0.000 | 0.000 | 3.633 | 1.087 | 12.213 | 18.933 | 0.000 | 1.537 | 2.752 | 0.000 | -7.681 | 0.000 | -7.820 | -0.000 |
F3 NW APARTMENT | 2.851 | -21.847 | 0.000 | 0.000 | 3.669 | 1.087 | 12.213 | 12.520 | 0.000 | 1.492 | 2.903 | 0.000 | -7.786 | 0.000 | -7.103 | -0.000 |
F3 SE APARTMENT | 1.378 | -26.570 | 0.000 | 0.000 | 3.640 | 1.087 | 12.213 | 18.759 | 0.000 | 1.535 | 3.247 | 0.000 | -7.495 | 0.000 | -7.792 | -0.000 |
F3 NE APARTMENT | 2.576 | -21.897 | 0.000 | 0.000 | 3.681 | 1.087 | 12.213 | 12.215 | 0.000 | 1.492 | 3.062 | 0.000 | -7.411 | 0.000 | -7.018 | -0.000 |
F3 N1 APARTMENT | 0.869 | -17.309 | 0.000 | 0.000 | 3.670 | 1.087 | 12.213 | 5.371 | 0.000 | 1.053 | 3.441 | 0.000 | -4.819 | 0.000 | -5.577 | -0.000 |
F3 N2 APARTMENT | 0.875 | -17.308 | 0.000 | 0.000 | 3.671 | 1.087 | 12.213 | 5.371 | 0.000 | 1.053 | 3.424 | 0.000 | -4.814 | 0.000 | -5.571 | -0.000 |
F3 S1 APARTMENT | 0.267 | -22.048 | 0.000 | 0.000 | 3.619 | 1.087 | 12.213 | 11.875 | 0.000 | 1.085 | 2.938 | 0.000 | -4.661 | 0.000 | -6.374 | -0.000 |
F3 S2 APARTMENT | 0.269 | -22.085 | 0.000 | 0.000 | 3.619 | 1.087 | 12.213 | 11.873 | 0.000 | 1.085 | 2.977 | 0.000 | -4.661 | 0.000 | -6.377 | -0.000 |
F4 SW APARTMENT | 1.719 | -26.362 | 0.000 | 0.000 | 3.633 | 1.087 | 12.213 | 18.622 | 0.000 | 1.687 | 3.403 | 0.000 | -7.762 | 0.000 | -8.240 | -0.000 |
F4 NW APARTMENT | 3.001 | -22.088 | 0.000 | 0.000 | 3.669 | 1.087 | 12.213 | 12.335 | 0.000 | 1.637 | 3.540 | 0.000 | -7.888 | 0.000 | -7.504 | -0.000 |
F4 SE APARTMENT | 1.538 | -26.471 | 0.000 | 0.000 | 3.642 | 1.087 | 12.213 | 18.463 | 0.000 | 1.685 | 3.581 | 0.000 | -7.554 | 0.000 | -8.184 | -0.000 |
F4 NE APARTMENT | 2.710 | -22.139 | 0.000 | 0.000 | 3.680 | 1.087 | 12.213 | 12.032 | 0.000 | 1.637 | 3.701 | 0.000 | -7.508 | 0.000 | -7.412 | -0.000 |
F4 N1 APARTMENT | 0.895 | -17.637 | 0.000 | 0.000 | 3.667 | 1.087 | 12.213 | 5.295 | 0.000 | 1.148 | 4.067 | 0.000 | -4.896 | 0.000 | -5.837 | 0.000 |
F4 N2 APARTMENT | 0.900 | -17.635 | 0.000 | 0.000 | 3.668 | 1.087 | 12.213 | 5.294 | 0.000 | 1.147 | 4.050 | 0.000 | -4.892 | 0.000 | -5.831 | -0.000 |
F4 S1 APARTMENT | 0.295 | -22.298 | 0.000 | 0.000 | 3.617 | 1.087 | 12.213 | 11.672 | 0.000 | 1.183 | 3.600 | 0.000 | -4.719 | 0.000 | -6.649 | -0.000 |
F4 S2 APARTMENT | 0.300 | -22.305 | 0.000 | 0.000 | 3.618 | 1.087 | 12.213 | 11.671 | 0.000 | 1.184 | 3.598 | 0.000 | -4.716 | 0.000 | -6.648 | -0.000 |
M SW APARTMENT | 1.866 | -26.641 | 0.000 | 0.000 | 3.635 | 1.087 | 12.213 | 18.375 | 0.000 | 1.808 | 4.223 | 0.000 | -7.824 | 0.000 | -8.741 | -0.000 |
M NW APARTMENT | 3.169 | -22.508 | 0.000 | 0.000 | 3.669 | 1.087 | 12.213 | 12.187 | 0.000 | 1.752 | 4.375 | 0.000 | -7.969 | 0.000 | -7.976 | -0.000 |
M SE APARTMENT | 1.684 | -26.719 | 0.000 | 0.000 | 3.644 | 1.087 | 12.213 | 18.221 | 0.000 | 1.805 | 4.350 | 0.000 | -7.610 | 0.000 | -8.674 | -0.000 |
M NE APARTMENT | 2.867 | -22.553 | 0.000 | 0.000 | 3.681 | 1.087 | 12.213 | 11.885 | 0.000 | 1.752 | 4.534 | 0.000 | -7.586 | 0.000 | -7.879 | -0.000 |
M N1 APARTMENT | 0.955 | -18.094 | 0.000 | 0.000 | 3.666 | 1.087 | 12.213 | 5.233 | 0.000 | 1.223 | 4.864 | 0.000 | -4.956 | 0.000 | -6.191 | 0.000 |
M N2 APARTMENT | 0.959 | -18.092 | 0.000 | 0.000 | 3.667 | 1.087 | 12.213 | 5.233 | 0.000 | 1.222 | 4.847 | 0.000 | -4.951 | 0.000 | -6.185 | 0.000 |
M S1 APARTMENT | 0.336 | -22.641 | 0.000 | 0.000 | 3.618 | 1.087 | 12.213 | 11.511 | 0.000 | 1.262 | 4.402 | 0.000 | -4.760 | 0.000 | -7.028 | -0.000 |
M S2 APARTMENT | 0.341 | -22.639 | 0.000 | 0.000 | 3.618 | 1.087 | 12.213 | 11.511 | 0.000 | 1.263 | 4.391 | 0.000 | -4.757 | 0.000 | -7.026 | -0.000 |
F6 SW APARTMENT | 2.146 | -25.816 | 0.000 | 0.000 | 3.643 | 1.087 | 12.213 | 18.210 | 0.000 | 1.908 | 3.513 | 0.000 | -7.811 | 0.000 | -9.093 | -0.000 |
F6 NW APARTMENT | 3.553 | -21.886 | 0.000 | 0.000 | 3.677 | 1.087 | 12.213 | 12.102 | 0.000 | 1.849 | 3.667 | 0.000 | -7.967 | 0.000 | -8.294 | -0.000 |
F6 SE APARTMENT | 1.951 | -25.888 | 0.000 | 0.000 | 3.653 | 1.087 | 12.213 | 18.060 | 0.000 | 1.904 | 3.633 | 0.000 | -7.595 | 0.000 | -9.017 | -0.000 |
F6 NE APARTMENT | 3.247 | -21.917 | 0.000 | 0.000 | 3.688 | 1.087 | 12.213 | 11.802 | 0.000 | 1.848 | 3.814 | 0.000 | -7.586 | 0.000 | -8.195 | -0.000 |
F6 N1 APARTMENT | 1.159 | -17.450 | 0.000 | 0.000 | 3.674 | 1.087 | 12.213 | 5.205 | 0.000 | 1.286 | 4.189 | 0.000 | -4.957 | 0.000 | -6.405 | 0.000 |
F6 N2 APARTMENT | 1.165 | -17.450 | 0.000 | 0.000 | 3.674 | 1.087 | 12.213 | 5.205 | 0.000 | 1.285 | 4.172 | 0.000 | -4.953 | 0.000 | -6.398 | 0.000 |
F6 S1 APARTMENT | 0.432 | -21.798 | 0.000 | 0.000 | 3.626 | 1.087 | 12.213 | 11.405 | 0.000 | 1.328 | 3.730 | 0.000 | -4.751 | 0.000 | -7.272 | -0.000 |
F6 S2 APARTMENT | 0.438 | -21.796 | 0.000 | 0.000 | 3.627 | 1.087 | 12.213 | 11.405 | 0.000 | 1.328 | 3.715 | 0.000 | -4.748 | 0.000 | -7.269 | -0.000 |
F7 SW APARTMENT | 2.389 | -25.397 | 0.000 | 0.000 | 3.649 | 1.087 | 12.213 | 18.059 | 0.000 | 1.994 | 3.227 | 0.000 | -7.813 | 0.000 | -9.406 | -0.000 |
F7 NW APARTMENT | 3.871 | -21.630 | 0.000 | 0.000 | 3.682 | 1.087 | 12.213 | 12.018 | 0.000 | 1.932 | 3.396 | 0.000 | -7.981 | 0.000 | -8.587 | -0.000 |
F7 SE APARTMENT | 2.181 | -25.465 | 0.000 | 0.000 | 3.659 | 1.087 | 12.213 | 17.911 | 0.000 | 1.991 | 3.345 | 0.000 | -7.595 | 0.000 | -9.325 | -0.000 |
F7 NE APARTMENT | 3.559 | -21.650 | 0.000 | 0.000 | 3.692 | 1.087 | 12.213 | 11.720 | 0.000 | 1.932 | 3.535 | 0.000 | -7.601 | 0.000 | -8.486 | -0.000 |
F7 N1 APARTMENT | 1.334 | -17.181 | 0.000 | 0.000 | 3.679 | 1.087 | 12.213 | 5.175 | 0.000 | 1.340 | 3.924 | 0.000 | -4.967 | 0.000 | -6.603 | -0.000 |
F7 N2 APARTMENT | 1.338 | -17.179 | 0.000 | 0.000 | 3.680 | 1.087 | 12.213 | 5.175 | 0.000 | 1.339 | 3.908 | 0.000 | -4.963 | 0.000 | -6.597 | -0.000 |
F7 S1 APARTMENT | 0.527 | -21.367 | 0.000 | 0.000 | 3.633 | 1.087 | 12.213 | 11.307 | 0.000 | 1.385 | 3.456 | 0.000 | -4.751 | 0.000 | -7.489 | -0.000 |
F7 S2 APARTMENT | 0.533 | -21.365 | 0.000 | 0.000 | 3.633 | 1.087 | 12.213 | 11.307 | 0.000 | 1.385 | 3.440 | 0.000 | -4.748 | 0.000 | -7.486 | -0.000 |
F8 SW APARTMENT | 2.623 | -25.209 | 0.000 | 0.000 | 3.654 | 1.087 | 12.213 | 17.920 | 0.000 | 2.077 | 3.168 | 0.000 | -7.822 | 0.000 | -9.711 | -0.000 |
F8 NW APARTMENT | 4.171 | -21.577 | 0.000 | 0.000 | 3.686 | 1.087 | 12.213 | 11.939 | 0.000 | 2.013 | 3.352 | 0.000 | -8.004 | 0.000 | -8.878 | -0.000 |
F8 SE APARTMENT | 2.409 | -25.272 | 0.000 | 0.000 | 3.664 | 1.087 | 12.213 | 17.774 | 0.000 | 2.074 | 3.282 | 0.000 | -7.604 | 0.000 | -9.626 | -0.000 |
F8 NE APARTMENT | 3.856 | -21.588 | 0.000 | 0.000 | 3.696 | 1.087 | 12.213 | 11.641 | 0.000 | 2.012 | 3.482 | 0.000 | -7.624 | 0.000 | -8.775 | -0.000 |
F8 N1 APARTMENT | 1.508 | -17.117 | 0.000 | 0.000 | 3.683 | 1.087 | 12.213 | 5.145 | 0.000 | 1.394 | 3.879 | 0.000 | -4.982 | 0.000 | -6.809 | -0.000 |
F8 N2 APARTMENT | 1.514 | -17.118 | 0.000 | 0.000 | 3.683 | 1.087 | 12.213 | 5.145 | 0.000 | 1.394 | 3.862 | 0.000 | -4.978 | 0.000 | -6.802 | -0.000 |
F8 S1 APARTMENT | 0.624 | -21.160 | 0.000 | 0.000 | 3.638 | 1.087 | 12.213 | 11.219 | 0.000 | 1.442 | 3.398 | 0.000 | -4.754 | 0.000 | -7.706 | -0.001 |
F8 S2 APARTMENT | 0.631 | -21.157 | 0.000 | 0.000 | 3.639 | 1.087 | 12.213 | 11.218 | 0.000 | 1.442 | 3.381 | 0.000 | -4.751 | 0.000 | -7.702 | -0.000 |
F9 SW APARTMENT | 3.016 | -25.586 | 0.000 | 0.000 | 3.658 | 1.087 | 12.213 | 17.793 | 0.000 | 2.162 | 3.483 | 0.000 | -7.837 | 0.000 | -9.989 | -0.000 |
F9 NW APARTMENT | 4.667 | -22.107 | 0.000 | 0.000 | 3.688 | 1.087 | 12.213 | 11.858 | 0.000 | 2.093 | 3.695 | 0.000 | -8.035 | 0.000 | -9.157 | -0.000 |
F9 SE APARTMENT | 2.757 | -25.638 | 0.000 | 0.000 | 3.668 | 1.087 | 12.213 | 17.648 | 0.000 | 2.159 | 3.621 | 0.000 | -7.617 | 0.000 | -9.898 | -0.000 |
F9 NE APARTMENT | 4.304 | -22.100 | 0.000 | 0.000 | 3.698 | 1.087 | 12.213 | 11.561 | 0.000 | 2.092 | 3.846 | 0.000 | -7.653 | 0.000 | -9.047 | -0.001 |
F9 N1 APARTMENT | 1.823 | -17.562 | 0.000 | 0.000 | 3.685 | 1.087 | 12.213 | 5.112 | 0.000 | 1.452 | 4.201 | 0.000 | -5.000 | 0.000 | -7.009 | -0.000 |
F9 N2 APARTMENT | 1.829 | -17.562 | 0.000 | 0.000 | 3.686 | 1.087 | 12.213 | 5.111 | 0.000 | 1.452 | 4.185 | 0.000 | -4.996 | 0.000 | -7.003 | -0.000 |
F9 S1 APARTMENT | 0.800 | -21.450 | 0.000 | 0.000 | 3.644 | 1.087 | 12.213 | 11.140 | 0.000 | 1.506 | 3.718 | 0.000 | -4.759 | 0.000 | -7.898 | -0.000 |
F9 S2 APARTMENT | 0.809 | -21.451 | 0.000 | 0.000 | 3.644 | 1.087 | 12.213 | 11.140 | 0.000 | 1.506 | 3.703 | 0.000 | -4.756 | 0.000 | -7.894 | -0.000 |
T SW APARTMENT | 5.477 | -27.735 | 0.000 | 0.000 | 3.679 | 1.087 | 12.213 | 17.361 | 0.000 | 2.221 | 3.469 | 0.000 | -7.558 | 0.000 | -10.213 | -0.000 |
T NW APARTMENT | 7.041 | -24.236 | 0.000 | 0.000 | 3.699 | 1.087 | 12.213 | 11.492 | 0.000 | 2.149 | 3.809 | 0.000 | -7.808 | 0.000 | -9.446 | -0.000 |
T SE APARTMENT | 5.043 | -27.546 | 0.000 | 0.000 | 3.689 | 1.087 | 12.213 | 17.230 | 0.000 | 2.220 | 3.563 | 0.000 | -7.358 | 0.000 | -10.141 | -0.000 |
T NE APARTMENT | 6.457 | -23.999 | 0.000 | 0.000 | 3.711 | 1.087 | 12.213 | 11.228 | 0.000 | 2.150 | 3.945 | 0.000 | -7.456 | 0.000 | -9.334 | -0.000 |
T N1 APARTMENT | 3.271 | -19.238 | 0.000 | 0.000 | 3.698 | 1.087 | 12.213 | 4.963 | 0.000 | 1.492 | 4.555 | 0.000 | -4.840 | 0.000 | -7.201 | -0.000 |
T N2 APARTMENT | 3.284 | -19.240 | 0.000 | 0.000 | 3.699 | 1.087 | 12.213 | 4.962 | 0.000 | 1.492 | 4.538 | 0.000 | -4.835 | 0.000 | -7.198 | -0.000 |
T S1 APARTMENT | 2.174 | -22.981 | 0.000 | 0.000 | 3.667 | 1.087 | 12.213 | 10.906 | 0.000 | 1.561 | 4.047 | 0.000 | -4.611 | 0.000 | -8.062 | -0.000 |
T S2 APARTMENT | 2.186 | -22.985 | 0.000 | 0.000 | 3.668 | 1.087 | 12.213 | 10.904 | 0.000 | 1.561 | 4.034 | 0.000 | -4.607 | 0.000 | -8.060 | -0.000 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 4.733 | 0.000 | 5.998 | 0.000 | 0.000 | -1.564 | 0.000 | -20.333 | -5.275 |
F2 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.193 | 0.000 | 0.090 | 0.000 | 0.000 | -1.018 | 0.000 | -0.572 | -17.133 |
F3 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.121 | 0.000 | 0.103 | 0.000 | 0.000 | -1.065 | 0.000 | -0.707 | -16.891 |
F4 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.074 | 0.000 | 0.111 | 0.000 | 0.000 | -1.091 | 0.000 | -0.803 | -16.730 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32.880 | 0.000 | 2.004 | 0.000 | 0.101 | 0.000 | 0.000 | -1.152 | 0.000 | -0.937 | -32.896 |
F6 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.028 | 0.000 | 0.128 | 0.000 | 0.000 | -1.101 | 0.000 | -0.927 | -16.566 |
F7 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.019 | 0.000 | 0.137 | 0.000 | 0.000 | -1.092 | 0.000 | -0.965 | -16.538 |
F8 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.004 | 0.000 | 0.143 | 0.000 | 0.000 | -1.093 | 0.000 | -1.006 | -16.487 |
F9 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 1.986 | 0.000 | 0.143 | 0.000 | 0.000 | -1.100 | 0.000 | -1.047 | -16.422 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 8.151 | 1.859 | 0.000 | 0.082 | 0.000 | 0.000 | -1.099 | 0.000 | -1.175 | -24.259 |
Total Facility | 162.086 | -1696.974 | 0.000 | 0.000 | 290.148 | 296.560 | 982.450 | 971.825 | 0.000 | 124.396 | 247.677 | 0.000 | -504.049 | 0.000 | -607.721 | -266.408 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 28-SEP-15:15 | 0.00 | -3273.71 | 0.00 | 0.00 | 48.55 | 45.40 | 470.89 | 3655.74 | 0.00 | 111.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1058.46 |
G NW APARTMENT | 01-AUG-17:20 | 0.00 | -3060.74 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 2720.82 | 0.00 | 165.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -643.50 |
OFFICE | 28-SEP-13:30 | 0.00 | -4334.05 | 0.00 | 0.00 | 65.20 | 2345.88 | 588.62 | 3235.66 | 0.00 | 92.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1993.63 |
G NE APARTMENT | 03-AUG-10:00 | 0.00 | -2194.21 | 0.00 | 0.00 | 40.69 | 12.97 | 406.15 | 2498.40 | 0.00 | 66.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -830.08 |
G N1 APARTMENT | 01-AUG-17:10 | 0.00 | -1537.76 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 752.35 | 0.00 | 82.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -115.34 |
G N2 APARTMENT | 01-AUG-17:10 | 0.00 | -1525.83 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 752.59 | 0.00 | 82.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -127.51 |
G S1 APARTMENT | 28-OCT-13:30 | 0.00 | -1953.84 | 0.00 | 0.00 | 40.22 | 12.97 | 382.60 | 3215.57 | 0.00 | 44.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1742.48 |
G S2 APARTMENT | 28-OCT-13:30 | 0.00 | -2014.41 | 0.00 | 0.00 | 40.47 | 12.97 | 382.60 | 3217.89 | 0.00 | 45.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1685.31 |
F2 SW APARTMENT | 28-SEP-14:45 | 0.00 | -3818.25 | 0.00 | 0.00 | 40.72 | 22.70 | 400.26 | 3858.36 | 0.00 | 155.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -658.83 |
F2 NW APARTMENT | 01-AUG-16:10 | 0.00 | -3498.52 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 3027.10 | 0.00 | 309.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -576.33 |
F2 SE APARTMENT | 28-SEP-13:45 | 0.00 | -3452.03 | 0.00 | 0.00 | 40.53 | 12.97 | 382.60 | 3067.99 | 0.00 | 139.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -191.16 |
F2 NE APARTMENT | 03-AUG-10:00 | 0.00 | -2630.90 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 2465.85 | 0.00 | 95.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -390.02 |
F2 N1 APARTMENT | 01-AUG-17:45 | 0.00 | -1844.65 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 750.73 | 0.00 | 166.46 | 109.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 N2 APARTMENT | 01-AUG-17:45 | 0.00 | -1835.07 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 750.90 | 0.00 | 166.46 | 99.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 S1 APARTMENT | 28-OCT-13:30 | 0.00 | -2387.83 | 0.00 | 0.00 | 39.64 | 12.97 | 382.60 | 3109.35 | 0.00 | 61.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1218.19 |
F2 S2 APARTMENT | 28-OCT-13:30 | 0.00 | -2409.92 | 0.00 | 0.00 | 39.70 | 12.97 | 382.60 | 3109.87 | 0.00 | 61.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1196.96 |
F3 SW APARTMENT | 28-SEP-14:45 | 0.00 | -3820.35 | 0.00 | 0.00 | 40.75 | 22.70 | 400.26 | 3808.74 | 0.00 | 183.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -635.46 |
F3 NW APARTMENT | 01-AUG-16:10 | 0.00 | -3550.42 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 3006.85 | 0.00 | 365.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -560.54 |
F3 SE APARTMENT | 29-OCT-13:45 | 0.00 | -3301.52 | 0.00 | 0.00 | 40.56 | 12.97 | 382.60 | 3142.75 | 0.00 | 104.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -382.25 |
F3 NE APARTMENT | 01-JUL-10:00 | 0.00 | -2655.89 | 0.00 | 0.00 | 40.61 | 12.97 | 406.15 | 2415.20 | 0.00 | 89.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -308.73 |
F3 N1 APARTMENT | 01-AUG-17:45 | 0.00 | -1887.47 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 751.09 | 0.00 | 196.73 | 121.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 N2 APARTMENT | 01-AUG-17:45 | 0.00 | -1877.96 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 751.26 | 0.00 | 196.72 | 111.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 S1 APARTMENT | 13-NOV-13:30 | 0.00 | -2476.07 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2935.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -21.68 | -879.69 |
F3 S2 APARTMENT | 13-NOV-13:00 | 0.00 | -2481.99 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 3065.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -46.14 | -997.67 |
F4 SW APARTMENT | 31-OCT-15:15 | 0.00 | -3816.20 | 0.00 | 0.00 | 48.91 | 45.40 | 470.89 | 3679.51 | 0.00 | 214.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -642.70 |
F4 NW APARTMENT | 01-AUG-16:10 | 0.00 | -3589.78 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 2991.75 | 0.00 | 408.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -548.52 |
F4 SE APARTMENT | 29-OCT-13:45 | 0.00 | -3306.44 | 0.00 | 0.00 | 40.55 | 12.97 | 382.60 | 3114.02 | 0.00 | 116.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -360.42 |
F4 NE APARTMENT | 04-AUG-14:00 | 0.00 | -2707.92 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 1618.19 | 0.00 | 554.07 | 99.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 N1 APARTMENT | 01-AUG-17:45 | 0.00 | -1917.51 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 751.12 | 0.00 | 219.49 | 128.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 N2 APARTMENT | 01-AUG-17:45 | 0.00 | -1908.05 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 751.29 | 0.00 | 219.48 | 119.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 S1 APARTMENT | 13-NOV-13:30 | 0.00 | -2510.36 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2912.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -25.53 | -818.77 |
F4 S2 APARTMENT | 13-NOV-13:30 | 0.00 | -2513.24 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2912.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -25.53 | -815.83 |
M SW APARTMENT | 28-SEP-14:45 | 0.00 | -3831.77 | 0.00 | 0.00 | 40.75 | 22.70 | 400.26 | 3737.35 | 0.00 | 221.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -590.98 |
M NW APARTMENT | 01-AUG-16:10 | 0.00 | -3643.45 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 2978.84 | 0.00 | 443.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -516.67 |
M SE APARTMENT | 29-OCT-13:30 | 0.00 | -3343.35 | 0.00 | 0.00 | 40.60 | 12.97 | 382.60 | 3196.15 | 0.00 | 128.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -417.88 |
M NE APARTMENT | 04-AUG-14:00 | 0.00 | -2751.71 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 1613.06 | 0.00 | 600.37 | 101.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N1 APARTMENT | 01-AUG-17:45 | 0.00 | -1964.37 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 750.58 | 0.00 | 238.13 | 157.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 01-AUG-17:45 | 0.00 | -1954.95 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 750.75 | 0.00 | 238.12 | 148.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | 28-OCT-13:30 | 0.00 | -2529.88 | 0.00 | 0.00 | 39.76 | 12.97 | 382.60 | 2976.41 | 0.00 | 88.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -970.01 |
M S2 APARTMENT | 28-OCT-13:30 | 0.00 | -2536.05 | 0.00 | 0.00 | 39.78 | 12.97 | 382.60 | 2976.65 | 0.00 | 88.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -964.26 |
F6 SW APARTMENT | 28-SEP-14:45 | 0.00 | -3789.67 | 0.00 | 0.00 | 40.75 | 22.70 | 400.26 | 3711.08 | 0.00 | 236.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -621.49 |
F6 NW APARTMENT | 01-AUG-16:10 | 0.00 | -3633.90 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 2969.42 | 0.00 | 472.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -546.53 |
F6 SE APARTMENT | 29-OCT-13:30 | 0.00 | -3319.04 | 0.00 | 0.00 | 40.67 | 12.97 | 382.60 | 3175.80 | 0.00 | 137.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -430.98 |
F6 NE APARTMENT | 02-AUG-16:10 | 0.00 | -2741.36 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 1378.88 | 0.00 | 461.27 | 162.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 N1 APARTMENT | 01-AUG-17:45 | 0.00 | -1947.70 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 751.05 | 0.00 | 254.01 | 124.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 N2 APARTMENT | 01-AUG-17:45 | 0.00 | -1938.37 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 751.21 | 0.00 | 254.00 | 115.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 S1 APARTMENT | 28-OCT-13:30 | 0.00 | -2509.91 | 0.00 | 0.00 | 39.86 | 12.97 | 382.60 | 2949.45 | 0.00 | 94.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -969.51 |
F6 S2 APARTMENT | 28-OCT-13:30 | 0.00 | -2515.99 | 0.00 | 0.00 | 39.88 | 12.97 | 382.60 | 2949.68 | 0.00 | 94.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -963.85 |
F7 SW APARTMENT | 28-SEP-14:45 | 0.00 | -3769.75 | 0.00 | 0.00 | 40.75 | 22.70 | 400.26 | 3687.34 | 0.00 | 249.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -630.55 |
F7 NW APARTMENT | 01-AUG-16:10 | 0.00 | -3643.66 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 2960.57 | 0.00 | 498.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -554.08 |
F7 SE APARTMENT | 29-OCT-13:15 | 0.00 | -3309.31 | 0.00 | 0.00 | 40.70 | 12.97 | 382.60 | 3205.42 | 0.00 | 148.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -480.41 |
F7 NE APARTMENT | 02-AUG-16:10 | 0.00 | -2757.81 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 1379.40 | 0.00 | 486.79 | 153.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 N1 APARTMENT | 01-AUG-17:45 | 0.00 | -1951.86 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 750.99 | 0.00 | 267.99 | 114.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 N2 APARTMENT | 01-AUG-17:45 | 0.00 | -1942.59 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 751.16 | 0.00 | 267.99 | 105.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 S1 APARTMENT | 28-OCT-13:30 | 0.00 | -2511.62 | 0.00 | 0.00 | 39.97 | 12.97 | 382.60 | 2925.21 | 0.00 | 100.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -949.45 |
F7 S2 APARTMENT | 28-OCT-13:30 | 0.00 | -2517.64 | 0.00 | 0.00 | 39.99 | 12.97 | 382.60 | 2925.45 | 0.00 | 100.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -943.85 |
F8 SW APARTMENT | 28-SEP-14:45 | 0.00 | -3760.98 | 0.00 | 0.00 | 40.75 | 22.70 | 400.26 | 3665.73 | 0.00 | 260.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -629.22 |
F8 NW APARTMENT | 01-AUG-16:10 | 0.00 | -3664.46 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 2952.22 | 0.00 | 522.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -548.37 |
F8 SE APARTMENT | 29-OCT-12:45 | 0.00 | -3303.95 | 0.00 | 0.00 | 40.69 | 12.97 | 388.49 | 3312.81 | 0.00 | 140.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -591.42 |
F8 NE APARTMENT | 02-AUG-16:10 | 0.00 | -2784.89 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 1379.26 | 0.00 | 509.67 | 157.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 N1 APARTMENT | 01-AUG-17:45 | 0.00 | -1970.24 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 750.57 | 0.00 | 280.57 | 121.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 N2 APARTMENT | 01-AUG-17:45 | 0.00 | -1961.04 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 750.74 | 0.00 | 280.56 | 111.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 S1 APARTMENT | 28-OCT-13:30 | 0.00 | -2527.52 | 0.00 | 0.00 | 40.09 | 12.97 | 382.60 | 2903.85 | 0.00 | 105.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -917.78 |
F8 S2 APARTMENT | 28-OCT-13:30 | 0.00 | -2533.50 | 0.00 | 0.00 | 40.11 | 12.97 | 382.60 | 2904.08 | 0.00 | 105.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -912.23 |
F9 SW APARTMENT | 01-AUG-15:30 | 0.00 | -3865.47 | 0.00 | 0.00 | 48.90 | 45.40 | 470.89 | 3061.04 | 0.00 | 605.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -366.47 |
F9 NW APARTMENT | 01-AUG-16:10 | 0.00 | -3770.97 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 2941.44 | 0.00 | 543.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -452.41 |
F9 SE APARTMENT | 28-SEP-13:30 | 0.00 | -3352.79 | 0.00 | 0.00 | 40.72 | 12.97 | 382.60 | 3031.81 | 0.00 | 230.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -346.00 |
F9 NE APARTMENT | 02-AUG-16:10 | 0.00 | -2900.82 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 1375.58 | 0.00 | 530.49 | 256.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 N1 APARTMENT | 01-AUG-17:45 | 0.00 | -2083.13 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 747.98 | 0.00 | 292.18 | 224.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 N2 APARTMENT | 01-AUG-17:45 | 0.00 | -2073.88 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 748.15 | 0.00 | 292.18 | 215.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 S1 APARTMENT | 28-OCT-13:30 | 0.00 | -2611.86 | 0.00 | 0.00 | 40.39 | 12.97 | 382.60 | 2886.30 | 0.00 | 112.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -822.72 |
F9 S2 APARTMENT | 28-OCT-13:30 | 0.00 | -2617.71 | 0.00 | 0.00 | 40.41 | 12.97 | 382.60 | 2886.51 | 0.00 | 112.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -817.27 |
T SW APARTMENT | 01-AUG-15:15 | 0.00 | -4760.03 | 0.00 | 0.00 | 48.90 | 45.40 | 470.89 | 3008.26 | 0.00 | 609.64 | 576.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 01-AUG-16:10 | 0.00 | -4606.09 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 2886.59 | 0.00 | 563.25 | 418.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SE APARTMENT | 28-SEP-13:30 | 0.00 | -4082.16 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 2974.78 | 0.00 | 239.10 | 431.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 02-AUG-16:10 | 0.00 | -3596.44 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 1334.05 | 0.00 | 549.58 | 974.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 02-AUG-15:15 | 0.00 | -2755.42 | 0.00 | 0.00 | 48.90 | 45.40 | 470.89 | 892.66 | 0.00 | 252.06 | 1045.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 02-AUG-15:30 | 0.00 | -2752.26 | 0.00 | 0.00 | 48.90 | 45.40 | 470.89 | 871.81 | 0.00 | 286.10 | 1029.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 28-OCT-13:30 | 0.00 | -3417.16 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 2846.84 | 0.00 | 119.41 | 14.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S2 APARTMENT | 28-OCT-13:30 | 0.00 | -3416.07 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 2846.84 | 0.00 | 119.41 | 13.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 01-AUG-15:30 | 0.00 | -211116.55 | 0.00 | 0.00 | 3926.90 | 11666.77 | 38153.89 | 135020.29 | 0.00 | 33901.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -11552.80 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 11-FEB-05:00 | 1923.01 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 440.11 | 0.00 | -1749.84 | 0.00 | -1046.08 | 0.00 |
G NW APARTMENT | 11-FEB-05:00 | 2019.99 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 350.06 | 0.00 | -1756.77 | 0.00 | -1046.08 | 0.00 |
OFFICE | 11-FEB-07:00 | 1842.36 | 0.00 | 0.00 | 0.00 | 0.00 | 469.18 | 194.24 | 0.00 | 0.00 | 0.00 | 190.02 | 0.00 | -1759.27 | 0.00 | -936.54 | 0.00 |
G NE APARTMENT | 11-FEB-05:00 | 2037.16 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 318.81 | 0.00 | -1742.69 | 0.00 | -1046.09 | 0.00 |
G N1 APARTMENT | 16-MAR-15:55 | 1349.01 | 0.00 | 0.00 | 0.00 | 55.44 | 45.40 | 470.89 | 48.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1256.83 | -712.27 |
G N2 APARTMENT | 16-MAR-15:55 | 1371.53 | 0.00 | 0.00 | 0.00 | 55.47 | 45.40 | 470.89 | 48.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1255.89 | -736.15 |
G S1 APARTMENT | 17-MAR-08:25 | 1342.08 | 0.00 | 0.00 | 0.00 | 46.33 | 12.97 | 394.37 | 33.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1188.86 | -640.02 |
G S2 APARTMENT | 17-MAR-08:25 | 1163.18 | 0.00 | 0.00 | 0.00 | 46.11 | 12.97 | 394.37 | 30.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1195.50 | -451.19 |
F2 SW APARTMENT | 11-FEB-05:00 | 2093.43 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 820.10 | 0.00 | -1841.92 | 0.00 | -1504.40 | 0.00 |
F2 NW APARTMENT | 11-FEB-04:15 | 2325.67 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 641.73 | 0.00 | -1827.74 | 0.00 | -1572.46 | 0.00 |
F2 SE APARTMENT | 11-FEB-05:00 | 2012.75 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 878.97 | 0.00 | -1820.12 | 0.00 | -1504.40 | 0.00 |
F2 NE APARTMENT | 11-FEB-04:00 | 2351.48 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 606.46 | 0.00 | -1784.62 | 0.00 | -1593.15 | 0.00 |
F2 N1 APARTMENT | 03-JAN-07:55 | 1513.25 | 0.00 | 0.00 | 0.00 | 157.37 | 42.16 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -180.64 | 0.00 | -1412.83 | -501.91 |
F2 N2 APARTMENT | 16-MAR-12:40 | 1525.70 | 0.00 | 0.00 | 0.00 | 45.88 | 12.97 | 388.49 | 157.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1512.75 | -617.76 |
F2 S1 APARTMENT | 16-MAR-16:00 | 1583.22 | 0.00 | 0.00 | 0.00 | 52.61 | 45.40 | 470.89 | 38.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1630.82 | -560.25 |
F2 S2 APARTMENT | 16-MAR-16:00 | 1600.78 | 0.00 | 0.00 | 0.00 | 52.51 | 45.40 | 470.89 | 37.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1631.04 | -576.33 |
F3 SW APARTMENT | 11-FEB-05:00 | 2321.78 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 908.47 | 0.00 | -1880.99 | 0.00 | -1782.06 | 0.00 |
F3 NW APARTMENT | 11-FEB-04:00 | 2586.17 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 742.69 | 0.00 | -1861.43 | 0.00 | -1887.25 | 0.00 |
F3 SE APARTMENT | 11-FEB-05:00 | 2319.10 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 879.40 | 0.00 | -1849.24 | 0.00 | -1782.06 | 0.00 |
F3 NE APARTMENT | 11-FEB-04:00 | 2614.24 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 679.06 | 0.00 | -1825.88 | 0.00 | -1887.25 | 0.00 |
F3 N1 APARTMENT | 03-JAN-07:55 | 1697.58 | 0.00 | 0.00 | 0.00 | 156.64 | 42.16 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -190.15 | 0.00 | -1555.25 | -533.59 |
F3 N2 APARTMENT | 03-JAN-07:55 | 1694.92 | 0.00 | 0.00 | 0.00 | 156.67 | 42.16 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -190.04 | 0.00 | -1555.21 | -531.11 |
F3 S1 APARTMENT | 16-MAR-16:00 | 1596.88 | 0.00 | 0.00 | 0.00 | 52.23 | 45.40 | 470.89 | 12.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1828.39 | -349.69 |
F3 S2 APARTMENT | 16-MAR-16:00 | 1599.94 | 0.00 | 0.00 | 0.00 | 52.23 | 45.40 | 470.89 | 12.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1828.41 | -352.79 |
F4 SW APARTMENT | 11-FEB-05:00 | 2552.32 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 913.28 | 0.00 | -1905.47 | 0.00 | -1992.93 | 0.00 |
F4 NW APARTMENT | 11-FEB-04:00 | 2827.16 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 754.12 | 0.00 | -1890.48 | 0.00 | -2110.64 | 0.00 |
F4 SE APARTMENT | 11-FEB-04:45 | 2568.07 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 878.10 | 0.00 | -1854.63 | 0.00 | -2024.34 | 0.00 |
F4 NE APARTMENT | 11-FEB-04:00 | 2850.50 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 691.67 | 0.00 | -1851.36 | 0.00 | -2110.64 | 0.00 |
F4 N1 APARTMENT | 16-MAR-12:40 | 1875.32 | 0.00 | 0.00 | 0.00 | 45.81 | 12.97 | 388.49 | 130.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1810.58 | -642.02 |
F4 N2 APARTMENT | 16-MAR-12:40 | 1911.68 | 0.00 | 0.00 | 0.00 | 45.86 | 12.97 | 388.49 | 130.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1809.29 | -680.35 |
F4 S1 APARTMENT | 16-MAR-12:45 | 1575.97 | 0.00 | 0.00 | 0.00 | 43.63 | 12.97 | 388.49 | 105.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2079.44 | -47.14 |
F4 S2 APARTMENT | 16-MAR-12:45 | 1573.56 | 0.00 | 0.00 | 0.00 | 43.67 | 12.97 | 388.49 | 106.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2079.41 | -45.30 |
M SW APARTMENT | 11-FEB-04:15 | 2741.40 | 0.00 | 0.00 | 0.00 | 189.67 | 19.46 | 223.68 | 0.00 | 0.00 | 0.00 | 973.06 | 0.00 | -1882.08 | 0.00 | -2265.18 | 0.00 |
M NW APARTMENT | 11-FEB-04:00 | 3019.59 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 768.38 | 0.00 | -1912.76 | 0.00 | -2295.05 | 0.00 |
M SE APARTMENT | 11-FEB-04:00 | 2761.55 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 939.66 | 0.00 | -1825.99 | 0.00 | -2295.05 | 0.00 |
M NE APARTMENT | 11-FEB-04:00 | 3038.57 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 707.75 | 0.00 | -1871.09 | 0.00 | -2295.05 | 0.00 |
M N1 APARTMENT | 16-MAR-12:40 | 2014.60 | 0.00 | 0.00 | 0.00 | 45.87 | 12.97 | 388.49 | 123.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1924.31 | -660.89 |
M N2 APARTMENT | 16-MAR-12:40 | 2003.28 | 0.00 | 0.00 | 0.00 | 45.91 | 12.97 | 388.49 | 123.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1924.20 | -650.32 |
M S1 APARTMENT | 16-MAR-12:45 | 1588.58 | 0.00 | 0.00 | 0.00 | 43.80 | 12.97 | 388.49 | 95.28 | 0.00 | 0.00 | 96.91 | 0.00 | 0.00 | 0.00 | -2226.03 | 0.00 |
M S2 APARTMENT | 16-MAR-12:45 | 1585.01 | 0.00 | 0.00 | 0.00 | 43.84 | 12.97 | 388.49 | 95.94 | 0.00 | 0.00 | 99.73 | 0.00 | 0.00 | 0.00 | -2225.98 | 0.00 |
F6 SW APARTMENT | 11-FEB-04:00 | 2961.79 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 952.35 | 0.00 | -1879.75 | 0.00 | -2454.22 | 0.00 |
F6 NW APARTMENT | 11-FEB-04:00 | 3232.33 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 730.15 | 0.00 | -1928.10 | 0.00 | -2454.22 | 0.00 |
F6 SE APARTMENT | 11-FEB-04:00 | 2978.96 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 891.62 | 0.00 | -1836.19 | 0.00 | -2454.22 | 0.00 |
F6 NE APARTMENT | 11-FEB-04:00 | 3244.92 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 674.01 | 0.00 | -1884.54 | 0.00 | -2454.22 | 0.00 |
F6 N1 APARTMENT | 16-MAR-12:40 | 1985.21 | 0.00 | 0.00 | 0.00 | 46.24 | 12.97 | 388.49 | 122.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2026.29 | -528.65 |
F6 N2 APARTMENT | 16-MAR-12:40 | 1975.11 | 0.00 | 0.00 | 0.00 | 46.28 | 12.97 | 388.49 | 122.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2026.20 | -519.21 |
F6 S1 APARTMENT | 16-MAR-12:40 | 1568.74 | 0.00 | 0.00 | 0.00 | 44.30 | 12.97 | 388.49 | 92.48 | 0.00 | 0.00 | 277.08 | 0.00 | 0.00 | 0.00 | -2384.06 | 0.00 |
F6 S2 APARTMENT | 16-MAR-12:40 | 1607.27 | 0.00 | 0.00 | 0.00 | 44.34 | 12.97 | 388.49 | 93.20 | 0.00 | 0.00 | 236.79 | 0.00 | 0.00 | 0.00 | -2383.05 | 0.00 |
F7 SW APARTMENT | 11-FEB-04:00 | 3144.70 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 921.54 | 0.00 | -1890.62 | 0.00 | -2595.46 | 0.00 |
F7 NW APARTMENT | 11-FEB-04:00 | 3407.37 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 709.82 | 0.00 | -1941.56 | 0.00 | -2595.46 | 0.00 |
F7 SE APARTMENT | 11-FEB-04:00 | 3158.13 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 862.95 | 0.00 | -1845.45 | 0.00 | -2595.46 | 0.00 |
F7 NE APARTMENT | 11-FEB-04:00 | 3415.37 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 656.68 | 0.00 | -1896.42 | 0.00 | -2595.46 | 0.00 |
F7 N1 APARTMENT | 23-JAN-14:10 | 2095.08 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -4.64 | 0.00 | -2320.09 | -213.34 |
F7 N2 APARTMENT | 23-JAN-14:10 | 2092.22 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -4.84 | 0.00 | -2320.09 | -210.28 |
F7 S1 APARTMENT | 17-MAR-08:25 | 1865.22 | 0.00 | 0.00 | 0.00 | 45.21 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -61.87 | 0.00 | -2017.83 | -238.07 |
F7 S2 APARTMENT | 17-MAR-08:25 | 1901.34 | 0.00 | 0.00 | 0.00 | 45.25 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -61.15 | 0.00 | -2016.85 | -275.94 |
F8 SW APARTMENT | 11-FEB-04:00 | 3297.77 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 906.24 | 0.00 | -1900.62 | 0.00 | -2723.22 | 0.00 |
F8 NW APARTMENT | 11-FEB-04:00 | 3554.79 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 702.41 | 0.00 | -1953.81 | 0.00 | -2723.22 | 0.00 |
F8 SE APARTMENT | 11-FEB-04:00 | 3308.41 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 849.08 | 0.00 | -1854.10 | 0.00 | -2723.22 | 0.00 |
F8 NE APARTMENT | 11-FEB-04:00 | 3559.79 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 650.92 | 0.00 | -1907.32 | 0.00 | -2723.23 | 0.00 |
F8 N1 APARTMENT | 23-JAN-14:10 | 2210.17 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -6.99 | 0.00 | -2420.75 | -225.42 |
F8 N2 APARTMENT | 23-JAN-14:10 | 2207.00 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -7.18 | 0.00 | -2420.75 | -222.06 |
F8 S1 APARTMENT | 17-MAR-08:25 | 2242.93 | 0.00 | 0.00 | 0.00 | 45.53 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -61.59 | 0.00 | -2090.91 | -543.31 |
F8 S2 APARTMENT | 17-MAR-08:25 | 2276.97 | 0.00 | 0.00 | 0.00 | 45.57 | 12.97 | 394.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -60.92 | 0.00 | -2089.99 | -578.98 |
F9 SW APARTMENT | 11-FEB-04:00 | 3468.29 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 860.29 | 0.00 | -1908.00 | 0.00 | -2840.41 | 0.00 |
F9 NW APARTMENT | 11-FEB-04:00 | 3711.29 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 672.29 | 0.00 | -1963.00 | 0.00 | -2840.41 | 0.00 |
F9 SE APARTMENT | 11-FEB-04:00 | 3476.90 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 803.96 | 0.00 | -1860.28 | 0.00 | -2840.41 | 0.00 |
F9 NE APARTMENT | 11-FEB-04:00 | 3712.58 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 623.28 | 0.00 | -1915.28 | 0.00 | -2840.41 | 0.00 |
F9 N1 APARTMENT | 23-JAN-14:10 | 2345.25 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -7.89 | 0.00 | -2514.66 | -265.69 |
F9 N2 APARTMENT | 23-JAN-14:10 | 2341.04 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -8.09 | 0.00 | -2514.66 | -261.28 |
F9 S1 APARTMENT | 16-MAR-12:55 | 2597.33 | 0.00 | 0.00 | 0.00 | 45.24 | 12.97 | 388.49 | 97.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2512.83 | -628.53 |
F9 S2 APARTMENT | 16-MAR-12:55 | 2632.17 | 0.00 | 0.00 | 0.00 | 45.28 | 12.97 | 388.49 | 98.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2511.92 | -665.00 |
T SW APARTMENT | 11-FEB-04:00 | 4417.90 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1863.00 | 0.00 | -2948.82 | -25.91 |
T NW APARTMENT | 11-FEB-04:00 | 4591.06 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1920.40 | 0.00 | -2948.82 | -141.67 |
T SE APARTMENT | 11-FEB-04:00 | 4405.35 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1816.78 | 0.00 | -2948.82 | -59.58 |
T NE APARTMENT | 11-FEB-04:00 | 4581.17 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1874.38 | 0.00 | -2948.82 | -177.80 |
T N1 APARTMENT | 11-FEB-04:00 | 2736.65 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1167.58 | 0.00 | -1778.72 | -210.18 |
T N2 APARTMENT | 11-FEB-04:00 | 2739.35 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1167.48 | 0.00 | -1778.72 | -212.98 |
T S1 APARTMENT | 16-MAR-12:55 | 2784.04 | 0.00 | 0.00 | 0.00 | 45.69 | 12.97 | 388.49 | 101.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2602.48 | -729.78 |
T S2 APARTMENT | 16-MAR-12:55 | 2778.99 | 0.00 | 0.00 | 0.00 | 45.72 | 12.97 | 388.49 | 101.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2602.41 | -725.36 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 11-FEB-04:00 | 180739.20 | 0.00 | 0.00 | 0.00 | 14984.00 | 6715.87 | 17923.60 | 0.00 | 0.00 | 0.00 | 49716.03 | 0.00 | -121500.52 | 0.00 | -148578.19 | 0.00 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:57
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:57
Sec1.1A-General InformationData | |
Weather File | Houston Bush Intercontinental TX USA TMY3 WMO#=722430 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 7836.48 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.50 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F2 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F3 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F4 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F6 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F7 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F8 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F9 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 7836.48 | 7059.89 | 776.58 |
Data | |
Number of hours heating loads not met | 47.25 |
Number of hours cooling loads not met | 313.50 |
Number of hours not met | 360.75 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 296.56 | 13120.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 162.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 49.16 | 0.00 | 140.95 | 205316.53 | 0.00 | 0.00 |
Space Cooling | 924.90 | 90227.27 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 73.12 | 2453.60 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 46.83 | 3653.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 659.86 | 20924.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 0.00 | 0.00 | 918.44 | 72689.02 | 0.00 | 0.00 |
Receptacle Equipment | 1137.32 | 57042.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 3386.78 | 1059.39 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 1137.32 | 3386.78 |
Natural Gas | 0.00 | 1059.39 |
Additional | 0.00 | 0.00 |
Total | 1137.32 | 4446.16 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 37.84 |
Space Heating | 6.27 |
Space Cooling | 118.02 |
Fans-Interior | 84.20 |
Service Water Heating | 0.00 |
Receptacle Equipment | 145.13 |
Miscellaneous | 40.70 |
Subtotal | 432.18 |
Natural Gas [MJ/m2] | |
Space Heating | 17.99 |
Service Water Heating | 117.20 |
Miscellaneous | -0.00 |
Subtotal | 135.19 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 6.67 |
Space Heating | 4.28 |
Space Cooling | 20.80 |
Fans-Interior | 14.84 |
Service Water Heating | 20.66 |
Receptacle Equipment | 25.58 |
Miscellaneous | 7.17 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:57
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.252480 |
G NW APARTMENT DIRECT AIR | 0.258263 |
OFFICE DIRECT AIR | 0.344380 |
G NE APARTMENT DIRECT AIR | 0.204253 |
G N1 APARTMENT DIRECT AIR | 0.130073 |
G N2 APARTMENT DIRECT AIR | 0.128983 |
G S1 APARTMENT DIRECT AIR | 0.127901 |
G S2 APARTMENT DIRECT AIR | 0.133629 |
F2 SW APARTMENT DIRECT AIR | 0.296815 |
F2 NW APARTMENT DIRECT AIR | 0.302203 |
F2 SE APARTMENT DIRECT AIR | 0.269410 |
F2 NE APARTMENT DIRECT AIR | 0.242948 |
F2 N1 APARTMENT DIRECT AIR | 0.158633 |
F2 N2 APARTMENT DIRECT AIR | 0.157773 |
F2 S1 APARTMENT DIRECT AIR | 0.157276 |
F2 S2 APARTMENT DIRECT AIR | 0.159245 |
F3 SW APARTMENT DIRECT AIR | 0.297920 |
F3 NW APARTMENT DIRECT AIR | 0.303478 |
F3 SE APARTMENT DIRECT AIR | 0.251132 |
F3 NE APARTMENT DIRECT AIR | 0.244751 |
F3 N1 APARTMENT DIRECT AIR | 0.161255 |
F3 N2 APARTMENT DIRECT AIR | 0.160404 |
F3 S1 APARTMENT DIRECT AIR | 0.160212 |
F3 S2 APARTMENT DIRECT AIR | 0.161002 |
F4 SW APARTMENT DIRECT AIR | 0.299129 |
F4 NW APARTMENT DIRECT AIR | 0.304622 |
F4 SE APARTMENT DIRECT AIR | 0.250010 |
F4 NE APARTMENT DIRECT AIR | 0.245512 |
F4 N1 APARTMENT DIRECT AIR | 0.163045 |
F4 N2 APARTMENT DIRECT AIR | 0.162201 |
F4 S1 APARTMENT DIRECT AIR | 0.161945 |
F4 S2 APARTMENT DIRECT AIR | 0.162552 |
M SW APARTMENT DIRECT AIR | 0.302131 |
M NW APARTMENT DIRECT AIR | 0.307643 |
M SE APARTMENT DIRECT AIR | 0.252508 |
M NE APARTMENT DIRECT AIR | 0.248227 |
M N1 APARTMENT DIRECT AIR | 0.166486 |
M N2 APARTMENT DIRECT AIR | 0.165647 |
M S1 APARTMENT DIRECT AIR | 0.165257 |
M S2 APARTMENT DIRECT AIR | 0.165833 |
F6 SW APARTMENT DIRECT AIR | 0.299663 |
F6 NW APARTMENT DIRECT AIR | 0.305044 |
F6 SE APARTMENT DIRECT AIR | 0.249858 |
F6 NE APARTMENT DIRECT AIR | 0.245461 |
F6 N1 APARTMENT DIRECT AIR | 0.164469 |
F6 N2 APARTMENT DIRECT AIR | 0.163640 |
F6 S1 APARTMENT DIRECT AIR | 0.163275 |
F6 S2 APARTMENT DIRECT AIR | 0.163843 |
F7 SW APARTMENT DIRECT AIR | 0.299171 |
F7 NW APARTMENT DIRECT AIR | 0.304497 |
F7 SE APARTMENT DIRECT AIR | 0.249176 |
F7 NE APARTMENT DIRECT AIR | 0.244741 |
F7 N1 APARTMENT DIRECT AIR | 0.164358 |
F7 N2 APARTMENT DIRECT AIR | 0.163536 |
F7 S1 APARTMENT DIRECT AIR | 0.163118 |
F7 S2 APARTMENT DIRECT AIR | 0.163680 |
F8 SW APARTMENT DIRECT AIR | 0.300045 |
F8 NW APARTMENT DIRECT AIR | 0.305335 |
F8 SE APARTMENT DIRECT AIR | 0.249844 |
F8 NE APARTMENT DIRECT AIR | 0.245353 |
F8 N1 APARTMENT DIRECT AIR | 0.165582 |
F8 N2 APARTMENT DIRECT AIR | 0.164767 |
F8 S1 APARTMENT DIRECT AIR | 0.164225 |
F8 S2 APARTMENT DIRECT AIR | 0.164784 |
F9 SW APARTMENT DIRECT AIR | 0.310054 |
F9 NW APARTMENT DIRECT AIR | 0.315567 |
F9 SE APARTMENT DIRECT AIR | 0.254950 |
F9 NE APARTMENT DIRECT AIR | 0.250119 |
F9 N1 APARTMENT DIRECT AIR | 0.175239 |
F9 N2 APARTMENT DIRECT AIR | 0.174424 |
F9 S1 APARTMENT DIRECT AIR | 0.171279 |
F9 S2 APARTMENT DIRECT AIR | 0.171829 |
T SW APARTMENT DIRECT AIR | 0.382080 |
T NW APARTMENT DIRECT AIR | 0.381499 |
T SE APARTMENT DIRECT AIR | 0.319003 |
T NE APARTMENT DIRECT AIR | 0.307674 |
T N1 APARTMENT DIRECT AIR | 0.229530 |
T N2 APARTMENT DIRECT AIR | 0.229513 |
T S1 APARTMENT DIRECT AIR | 0.248503 |
T S2 APARTMENT DIRECT AIR | 0.249019 |
Maximum Flow Rate [m3/s] | |
AIRLOOP G SW MAIN BRANCH | 0.252480 |
AIRLOOP G NW MAIN BRANCH | 0.258263 |
AIRLOOP OFFICE MAIN BRANCH | 0.344380 |
AIRLOOP G NE MAIN BRANCH | 0.204253 |
AIRLOOP G N1 MAIN BRANCH | 0.130073 |
AIRLOOP G N2 MAIN BRANCH | 0.128983 |
AIRLOOP G S1 MAIN BRANCH | 0.127901 |
AIRLOOP G S2 MAIN BRANCH | 0.133629 |
AIRLOOP F2 SW MAIN BRANCH | 0.296815 |
AIRLOOP F2 NW MAIN BRANCH | 0.302203 |
AIRLOOP F2 SE MAIN BRANCH | 0.269410 |
AIRLOOP F2 NE MAIN BRANCH | 0.242948 |
AIRLOOP F2 N1 MAIN BRANCH | 0.158633 |
AIRLOOP F2 N2 MAIN BRANCH | 0.157773 |
AIRLOOP F2 S1 MAIN BRANCH | 0.157276 |
AIRLOOP F2 S2 MAIN BRANCH | 0.159245 |
AIRLOOP F3 SW MAIN BRANCH | 0.297920 |
AIRLOOP F3 NW MAIN BRANCH | 0.303478 |
AIRLOOP F3 SE MAIN BRANCH | 0.251132 |
AIRLOOP F3 NE MAIN BRANCH | 0.244751 |
AIRLOOP F3 N1 MAIN BRANCH | 0.161255 |
AIRLOOP F3 N2 MAIN BRANCH | 0.160404 |
AIRLOOP F3 S1 MAIN BRANCH | 0.160212 |
AIRLOOP F3 S2 MAIN BRANCH | 0.161002 |
AIRLOOP F4 SW MAIN BRANCH | 0.299129 |
AIRLOOP F4 NW MAIN BRANCH | 0.304622 |
AIRLOOP F4 SE MAIN BRANCH | 0.250010 |
AIRLOOP F4 NE MAIN BRANCH | 0.245512 |
AIRLOOP F4 N1 MAIN BRANCH | 0.163045 |
AIRLOOP F4 N2 MAIN BRANCH | 0.162201 |
AIRLOOP F4 S1 MAIN BRANCH | 0.161945 |
AIRLOOP F4 S2 MAIN BRANCH | 0.162552 |
AIRLOOP M SW MAIN BRANCH | 0.302131 |
AIRLOOP M NW MAIN BRANCH | 0.307643 |
AIRLOOP M SE MAIN BRANCH | 0.252508 |
AIRLOOP M NE MAIN BRANCH | 0.248227 |
AIRLOOP M N1 MAIN BRANCH | 0.166486 |
AIRLOOP M N2 MAIN BRANCH | 0.165647 |
AIRLOOP M S1 MAIN BRANCH | 0.165257 |
AIRLOOP M S2 MAIN BRANCH | 0.165833 |
AIRLOOP F6 SW MAIN BRANCH | 0.299663 |
AIRLOOP F6 NW MAIN BRANCH | 0.305044 |
AIRLOOP F6 SE MAIN BRANCH | 0.249858 |
AIRLOOP F6 NE MAIN BRANCH | 0.245461 |
AIRLOOP F6 N1 MAIN BRANCH | 0.164469 |
AIRLOOP F6 N2 MAIN BRANCH | 0.163640 |
AIRLOOP F6 S1 MAIN BRANCH | 0.163275 |
AIRLOOP F6 S2 MAIN BRANCH | 0.163843 |
AIRLOOP F7 SW MAIN BRANCH | 0.299171 |
AIRLOOP F7 NW MAIN BRANCH | 0.304497 |
AIRLOOP F7 SE MAIN BRANCH | 0.249176 |
AIRLOOP F7 NE MAIN BRANCH | 0.244741 |
AIRLOOP F7 N1 MAIN BRANCH | 0.164358 |
AIRLOOP F7 N2 MAIN BRANCH | 0.163536 |
AIRLOOP F7 S1 MAIN BRANCH | 0.163118 |
AIRLOOP F7 S2 MAIN BRANCH | 0.163680 |
AIRLOOP F8 SW MAIN BRANCH | 0.300045 |
AIRLOOP F8 NW MAIN BRANCH | 0.305335 |
AIRLOOP F8 SE MAIN BRANCH | 0.249844 |
AIRLOOP F8 NE MAIN BRANCH | 0.245353 |
AIRLOOP F8 N1 MAIN BRANCH | 0.165582 |
AIRLOOP F8 N2 MAIN BRANCH | 0.164767 |
AIRLOOP F8 S1 MAIN BRANCH | 0.164225 |
AIRLOOP F8 S2 MAIN BRANCH | 0.164784 |
AIRLOOP F9 SW MAIN BRANCH | 0.310054 |
AIRLOOP F9 NW MAIN BRANCH | 0.315567 |
AIRLOOP F9 SE MAIN BRANCH | 0.254950 |
AIRLOOP F9 NE MAIN BRANCH | 0.250119 |
AIRLOOP F9 N1 MAIN BRANCH | 0.175239 |
AIRLOOP F9 N2 MAIN BRANCH | 0.174424 |
AIRLOOP F9 S1 MAIN BRANCH | 0.171279 |
AIRLOOP F9 S2 MAIN BRANCH | 0.171829 |
AIRLOOP T SW MAIN BRANCH | 0.382080 |
AIRLOOP T NW MAIN BRANCH | 0.381499 |
AIRLOOP T SE MAIN BRANCH | 0.319003 |
AIRLOOP T NE MAIN BRANCH | 0.307674 |
AIRLOOP T N1 MAIN BRANCH | 0.229530 |
AIRLOOP T N2 MAIN BRANCH | 0.229513 |
AIRLOOP T S1 MAIN BRANCH | 0.248503 |
AIRLOOP T S2 MAIN BRANCH | 0.249019 |
Design Supply Air Flow Rate [m3/s] | |
AIRLOOP G SW | 0.252480 |
AIRLOOP G NW | 0.258263 |
AIRLOOP OFFICE | 0.344380 |
AIRLOOP G NE | 0.204253 |
AIRLOOP G N1 | 0.130073 |
AIRLOOP G N2 | 0.128983 |
AIRLOOP G S1 | 0.127901 |
AIRLOOP G S2 | 0.133629 |
AIRLOOP F2 SW | 0.296815 |
AIRLOOP F2 NW | 0.302203 |
AIRLOOP F2 SE | 0.269410 |
AIRLOOP F2 NE | 0.242948 |
AIRLOOP F2 N1 | 0.158633 |
AIRLOOP F2 N2 | 0.157773 |
AIRLOOP F2 S1 | 0.157276 |
AIRLOOP F2 S2 | 0.159245 |
AIRLOOP F3 SW | 0.297920 |
AIRLOOP F3 NW | 0.303478 |
AIRLOOP F3 SE | 0.251132 |
AIRLOOP F3 NE | 0.244751 |
AIRLOOP F3 N1 | 0.161255 |
AIRLOOP F3 N2 | 0.160404 |
AIRLOOP F3 S1 | 0.160212 |
AIRLOOP F3 S2 | 0.161002 |
AIRLOOP F4 SW | 0.299129 |
AIRLOOP F4 NW | 0.304622 |
AIRLOOP F4 SE | 0.250010 |
AIRLOOP F4 NE | 0.245512 |
AIRLOOP F4 N1 | 0.163045 |
AIRLOOP F4 N2 | 0.162201 |
AIRLOOP F4 S1 | 0.161945 |
AIRLOOP F4 S2 | 0.162552 |
AIRLOOP M SW | 0.302131 |
AIRLOOP M NW | 0.307643 |
AIRLOOP M SE | 0.252508 |
AIRLOOP M NE | 0.248227 |
AIRLOOP M N1 | 0.166486 |
AIRLOOP M N2 | 0.165647 |
AIRLOOP M S1 | 0.165257 |
AIRLOOP M S2 | 0.165833 |
AIRLOOP F6 SW | 0.299663 |
AIRLOOP F6 NW | 0.305044 |
AIRLOOP F6 SE | 0.249858 |
AIRLOOP F6 NE | 0.245461 |
AIRLOOP F6 N1 | 0.164469 |
AIRLOOP F6 N2 | 0.163640 |
AIRLOOP F6 S1 | 0.163275 |
AIRLOOP F6 S2 | 0.163843 |
AIRLOOP F7 SW | 0.299171 |
AIRLOOP F7 NW | 0.304497 |
AIRLOOP F7 SE | 0.249176 |
AIRLOOP F7 NE | 0.244741 |
AIRLOOP F7 N1 | 0.164358 |
AIRLOOP F7 N2 | 0.163536 |
AIRLOOP F7 S1 | 0.163118 |
AIRLOOP F7 S2 | 0.163680 |
AIRLOOP F8 SW | 0.300045 |
AIRLOOP F8 NW | 0.305335 |
AIRLOOP F8 SE | 0.249844 |
AIRLOOP F8 NE | 0.245353 |
AIRLOOP F8 N1 | 0.165582 |
AIRLOOP F8 N2 | 0.164767 |
AIRLOOP F8 S1 | 0.164225 |
AIRLOOP F8 S2 | 0.164784 |
AIRLOOP F9 SW | 0.310054 |
AIRLOOP F9 NW | 0.315567 |
AIRLOOP F9 SE | 0.254950 |
AIRLOOP F9 NE | 0.250119 |
AIRLOOP F9 N1 | 0.175239 |
AIRLOOP F9 N2 | 0.174424 |
AIRLOOP F9 S1 | 0.171279 |
AIRLOOP F9 S2 | 0.171829 |
AIRLOOP T SW | 0.382080 |
AIRLOOP T NW | 0.381499 |
AIRLOOP T SE | 0.319003 |
AIRLOOP T NE | 0.307674 |
AIRLOOP T N1 | 0.229530 |
AIRLOOP T N2 | 0.229513 |
AIRLOOP T S1 | 0.248503 |
AIRLOOP T S2 | 0.249019 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
AIRLOOP G SW OA CONTROLLER | 0.252480 | 0.025952 |
AIRLOOP G NW OA CONTROLLER | 0.258263 | 0.025952 |
AIRLOOP OFFICE OA CONTROLLER | 0.344380 | 0.038103 |
AIRLOOP G NE OA CONTROLLER | 0.204253 | 0.025952 |
AIRLOOP G N1 OA CONTROLLER | 0.130073 | 0.025952 |
AIRLOOP G N2 OA CONTROLLER | 0.128983 | 0.025952 |
AIRLOOP G S1 OA CONTROLLER | 0.127901 | 0.025952 |
AIRLOOP G S2 OA CONTROLLER | 0.133629 | 0.025952 |
AIRLOOP F2 SW OA CONTROLLER | 0.296815 | 0.025952 |
AIRLOOP F2 NW OA CONTROLLER | 0.302203 | 0.025952 |
AIRLOOP F2 SE OA CONTROLLER | 0.269410 | 0.025952 |
AIRLOOP F2 NE OA CONTROLLER | 0.242948 | 0.025952 |
AIRLOOP F2 N1 OA CONTROLLER | 0.158633 | 0.025952 |
AIRLOOP F2 N2 OA CONTROLLER | 0.157773 | 0.025952 |
AIRLOOP F2 S1 OA CONTROLLER | 0.157276 | 0.025952 |
AIRLOOP F2 S2 OA CONTROLLER | 0.159245 | 0.025952 |
AIRLOOP F3 SW OA CONTROLLER | 0.297920 | 0.025952 |
AIRLOOP F3 NW OA CONTROLLER | 0.303478 | 0.025952 |
AIRLOOP F3 SE OA CONTROLLER | 0.251132 | 0.025952 |
AIRLOOP F3 NE OA CONTROLLER | 0.244751 | 0.025952 |
AIRLOOP F3 N1 OA CONTROLLER | 0.161255 | 0.025952 |
AIRLOOP F3 N2 OA CONTROLLER | 0.160404 | 0.025952 |
AIRLOOP F3 S1 OA CONTROLLER | 0.160212 | 0.025952 |
AIRLOOP F3 S2 OA CONTROLLER | 0.161002 | 0.025952 |
AIRLOOP F4 SW OA CONTROLLER | 0.299129 | 0.025952 |
AIRLOOP F4 NW OA CONTROLLER | 0.304622 | 0.025952 |
AIRLOOP F4 SE OA CONTROLLER | 0.250010 | 0.025952 |
AIRLOOP F4 NE OA CONTROLLER | 0.245512 | 0.025952 |
AIRLOOP F4 N1 OA CONTROLLER | 0.163045 | 0.025952 |
AIRLOOP F4 N2 OA CONTROLLER | 0.162201 | 0.025952 |
AIRLOOP F4 S1 OA CONTROLLER | 0.161945 | 0.025952 |
AIRLOOP F4 S2 OA CONTROLLER | 0.162552 | 0.025952 |
AIRLOOP M SW OA CONTROLLER | 0.302131 | 0.025952 |
AIRLOOP M NW OA CONTROLLER | 0.307643 | 0.025952 |
AIRLOOP M SE OA CONTROLLER | 0.252508 | 0.025952 |
AIRLOOP M NE OA CONTROLLER | 0.248227 | 0.025952 |
AIRLOOP M N1 OA CONTROLLER | 0.166486 | 0.025952 |
AIRLOOP M N2 OA CONTROLLER | 0.165647 | 0.025952 |
AIRLOOP M S1 OA CONTROLLER | 0.165257 | 0.025952 |
AIRLOOP M S2 OA CONTROLLER | 0.165833 | 0.025952 |
AIRLOOP F6 SW OA CONTROLLER | 0.299663 | 0.025952 |
AIRLOOP F6 NW OA CONTROLLER | 0.305044 | 0.025952 |
AIRLOOP F6 SE OA CONTROLLER | 0.249858 | 0.025952 |
AIRLOOP F6 NE OA CONTROLLER | 0.245461 | 0.025952 |
AIRLOOP F6 N1 OA CONTROLLER | 0.164469 | 0.025952 |
AIRLOOP F6 N2 OA CONTROLLER | 0.163640 | 0.025952 |
AIRLOOP F6 S1 OA CONTROLLER | 0.163275 | 0.025952 |
AIRLOOP F6 S2 OA CONTROLLER | 0.163843 | 0.025952 |
AIRLOOP F7 SW OA CONTROLLER | 0.299171 | 0.025952 |
AIRLOOP F7 NW OA CONTROLLER | 0.304497 | 0.025952 |
AIRLOOP F7 SE OA CONTROLLER | 0.249176 | 0.025952 |
AIRLOOP F7 NE OA CONTROLLER | 0.244741 | 0.025952 |
AIRLOOP F7 N1 OA CONTROLLER | 0.164358 | 0.025952 |
AIRLOOP F7 N2 OA CONTROLLER | 0.163536 | 0.025952 |
AIRLOOP F7 S1 OA CONTROLLER | 0.163118 | 0.025952 |
AIRLOOP F7 S2 OA CONTROLLER | 0.163680 | 0.025952 |
AIRLOOP F8 SW OA CONTROLLER | 0.300045 | 0.025952 |
AIRLOOP F8 NW OA CONTROLLER | 0.305335 | 0.025952 |
AIRLOOP F8 SE OA CONTROLLER | 0.249844 | 0.025952 |
AIRLOOP F8 NE OA CONTROLLER | 0.245353 | 0.025952 |
AIRLOOP F8 N1 OA CONTROLLER | 0.165582 | 0.025952 |
AIRLOOP F8 N2 OA CONTROLLER | 0.164767 | 0.025952 |
AIRLOOP F8 S1 OA CONTROLLER | 0.164225 | 0.025952 |
AIRLOOP F8 S2 OA CONTROLLER | 0.164784 | 0.025952 |
AIRLOOP F9 SW OA CONTROLLER | 0.310054 | 0.025952 |
AIRLOOP F9 NW OA CONTROLLER | 0.315567 | 0.025952 |
AIRLOOP F9 SE OA CONTROLLER | 0.254950 | 0.025952 |
AIRLOOP F9 NE OA CONTROLLER | 0.250119 | 0.025952 |
AIRLOOP F9 N1 OA CONTROLLER | 0.175239 | 0.025952 |
AIRLOOP F9 N2 OA CONTROLLER | 0.174424 | 0.025952 |
AIRLOOP F9 S1 OA CONTROLLER | 0.171279 | 0.025952 |
AIRLOOP F9 S2 OA CONTROLLER | 0.171829 | 0.025952 |
AIRLOOP T SW OA CONTROLLER | 0.382080 | 0.025952 |
AIRLOOP T NW OA CONTROLLER | 0.381499 | 0.025952 |
AIRLOOP T SE OA CONTROLLER | 0.319003 | 0.025952 |
AIRLOOP T NE OA CONTROLLER | 0.307674 | 0.025952 |
AIRLOOP T N1 OA CONTROLLER | 0.229530 | 0.025952 |
AIRLOOP T N2 OA CONTROLLER | 0.229513 | 0.025952 |
AIRLOOP T S1 OA CONTROLLER | 0.248503 | 0.025952 |
AIRLOOP T S2 OA CONTROLLER | 0.249019 | 0.025952 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity [W] | Rated Sensible Cooling Capacity [W] | Rated Water Flow Rate [m3/s] | |
HEAT PUMP COOLING MODE AIRLOOP G SW | 0.252480 | 4608.67 | 3128.39 | 0.000101 |
HEAT PUMP COOLING MODE AIRLOOP G NW | 0.258263 | 4679.76 | 3185.09 | 0.000102 |
HEAT PUMP COOLING MODE AIRLOOP OFFICE | 0.344380 | 6206.62 | 4237.38 | 0.000136 |
HEAT PUMP COOLING MODE AIRLOOP G NE | 0.204253 | 3858.00 | 2571.04 | 0.000084 |
HEAT PUMP COOLING MODE AIRLOOP G N1 | 0.130073 | 2735.61 | 1742.48 | 0.000060 |
HEAT PUMP COOLING MODE AIRLOOP G N2 | 0.128983 | 2719.38 | 1730.42 | 0.000059 |
HEAT PUMP COOLING MODE AIRLOOP G S1 | 0.127901 | 2760.70 | 1745.35 | 0.000060 |
HEAT PUMP COOLING MODE AIRLOOP G S2 | 0.133629 | 2844.61 | 1808.67 | 0.000062 |
HEAT PUMP COOLING MODE AIRLOOP F2 SW | 0.296815 | 5325.85 | 3639.85 | 0.000116 |
HEAT PUMP COOLING MODE AIRLOOP F2 NW | 0.302203 | 5397.15 | 3694.82 | 0.000118 |
HEAT PUMP COOLING MODE AIRLOOP F2 SE | 0.269410 | 4908.14 | 3327.10 | 0.000107 |
HEAT PUMP COOLING MODE AIRLOOP F2 NE | 0.242948 | 4499.55 | 3022.68 | 0.000098 |
HEAT PUMP COOLING MODE AIRLOOP F2 N1 | 0.158633 | 3205.84 | 2075.61 | 0.000070 |
HEAT PUMP COOLING MODE AIRLOOP F2 N2 | 0.157773 | 3193.10 | 2066.10 | 0.000070 |
HEAT PUMP COOLING MODE AIRLOOP F2 S1 | 0.157276 | 3237.26 | 2085.92 | 0.000071 |
HEAT PUMP COOLING MODE AIRLOOP F2 S2 | 0.159245 | 3265.91 | 2107.62 | 0.000071 |
HEAT PUMP COOLING MODE AIRLOOP F3 SW | 0.297920 | 5394.79 | 3668.54 | 0.000118 |
HEAT PUMP COOLING MODE AIRLOOP F3 NW | 0.303478 | 5468.75 | 3725.42 | 0.000119 |
HEAT PUMP COOLING MODE AIRLOOP F3 SE | 0.251132 | 4696.98 | 3143.00 | 0.000103 |
HEAT PUMP COOLING MODE AIRLOOP F3 NE | 0.244751 | 4576.48 | 3058.90 | 0.000100 |
HEAT PUMP COOLING MODE AIRLOOP F3 N1 | 0.161255 | 3272.61 | 2114.19 | 0.000071 |
HEAT PUMP COOLING MODE AIRLOOP F3 N2 | 0.160404 | 3259.96 | 2104.76 | 0.000071 |
HEAT PUMP COOLING MODE AIRLOOP F3 S1 | 0.160212 | 3308.04 | 2127.80 | 0.000072 |
HEAT PUMP COOLING MODE AIRLOOP F3 S2 | 0.161002 | 3319.52 | 2136.49 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F4 SW | 0.299129 | 5451.62 | 3694.22 | 0.000119 |
HEAT PUMP COOLING MODE AIRLOOP F4 NW | 0.304622 | 5524.82 | 3750.42 | 0.000121 |
HEAT PUMP COOLING MODE AIRLOOP F4 SE | 0.250010 | 4718.56 | 3142.93 | 0.000103 |
HEAT PUMP COOLING MODE AIRLOOP F4 NE | 0.245512 | 4633.39 | 3083.82 | 0.000101 |
HEAT PUMP COOLING MODE AIRLOOP F4 N1 | 0.163045 | 3320.05 | 2141.18 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F4 N2 | 0.162201 | 3307.46 | 2131.82 | 0.000072 |
HEAT PUMP COOLING MODE AIRLOOP F4 S1 | 0.161945 | 3354.28 | 2154.07 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F4 S2 | 0.162552 | 3363.09 | 2160.73 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP M SW | 0.302131 | 5526.84 | 3737.31 | 0.000121 |
HEAT PUMP COOLING MODE AIRLOOP M NW | 0.307643 | 5600.46 | 3793.75 | 0.000122 |
HEAT PUMP COOLING MODE AIRLOOP M SE | 0.252508 | 4785.39 | 3180.37 | 0.000105 |
HEAT PUMP COOLING MODE AIRLOOP M NE | 0.248227 | 4703.28 | 3123.64 | 0.000103 |
HEAT PUMP COOLING MODE AIRLOOP M N1 | 0.166486 | 3387.85 | 2185.00 | 0.000074 |
HEAT PUMP COOLING MODE AIRLOOP M N2 | 0.165647 | 3375.33 | 2175.71 | 0.000074 |
HEAT PUMP COOLING MODE AIRLOOP M S1 | 0.165257 | 3419.96 | 2196.49 | 0.000075 |
HEAT PUMP COOLING MODE AIRLOOP M S2 | 0.165833 | 3428.32 | 2202.82 | 0.000075 |
HEAT PUMP COOLING MODE AIRLOOP F6 SW | 0.299663 | 5523.95 | 3721.49 | 0.000121 |
HEAT PUMP COOLING MODE AIRLOOP F6 NW | 0.305044 | 5590.33 | 3773.87 | 0.000122 |
HEAT PUMP COOLING MODE AIRLOOP F6 SE | 0.249858 | 4772.72 | 3159.74 | 0.000104 |
HEAT PUMP COOLING MODE AIRLOOP F6 NE | 0.245461 | 4688.82 | 3101.74 | 0.000102 |
HEAT PUMP COOLING MODE AIRLOOP F6 N1 | 0.164469 | 3372.72 | 2167.85 | 0.000074 |
HEAT PUMP COOLING MODE AIRLOOP F6 N2 | 0.163640 | 3360.28 | 2158.65 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP F6 S1 | 0.163275 | 3405.06 | 2179.51 | 0.000074 |
HEAT PUMP COOLING MODE AIRLOOP F6 S2 | 0.163843 | 3413.32 | 2185.74 | 0.000075 |
HEAT PUMP COOLING MODE AIRLOOP F7 SW | 0.299171 | 5540.59 | 3723.67 | 0.000121 |
HEAT PUMP COOLING MODE AIRLOOP F7 NW | 0.304497 | 5606.28 | 3775.47 | 0.000122 |
HEAT PUMP COOLING MODE AIRLOOP F7 SE | 0.249176 | 4785.33 | 3159.70 | 0.000105 |
HEAT PUMP COOLING MODE AIRLOOP F7 NE | 0.244741 | 4700.78 | 3101.28 | 0.000103 |
HEAT PUMP COOLING MODE AIRLOOP F7 N1 | 0.164358 | 3383.77 | 2171.06 | 0.000074 |
HEAT PUMP COOLING MODE AIRLOOP F7 N2 | 0.163536 | 3371.40 | 2161.93 | 0.000074 |
HEAT PUMP COOLING MODE AIRLOOP F7 S1 | 0.163118 | 3415.24 | 2182.10 | 0.000075 |
HEAT PUMP COOLING MODE AIRLOOP F7 S2 | 0.163680 | 3423.44 | 2188.28 | 0.000075 |
HEAT PUMP COOLING MODE AIRLOOP F8 SW | 0.300045 | 5574.45 | 3740.09 | 0.000122 |
HEAT PUMP COOLING MODE AIRLOOP F8 NW | 0.305335 | 5639.71 | 3791.51 | 0.000123 |
HEAT PUMP COOLING MODE AIRLOOP F8 SE | 0.249844 | 4815.18 | 3173.73 | 0.000105 |
HEAT PUMP COOLING MODE AIRLOOP F8 NE | 0.245353 | 4729.75 | 3114.70 | 0.000103 |
HEAT PUMP COOLING MODE AIRLOOP F8 N1 | 0.165582 | 3413.26 | 2188.54 | 0.000075 |
HEAT PUMP COOLING MODE AIRLOOP F8 N2 | 0.164767 | 3400.99 | 2179.49 | 0.000074 |
HEAT PUMP COOLING MODE AIRLOOP F8 S1 | 0.164225 | 3442.85 | 2198.25 | 0.000075 |
HEAT PUMP COOLING MODE AIRLOOP F8 S2 | 0.164784 | 3451.01 | 2204.39 | 0.000075 |
HEAT PUMP COOLING MODE AIRLOOP F9 SW | 0.310054 | 5733.40 | 3853.76 | 0.000125 |
HEAT PUMP COOLING MODE AIRLOOP F9 NW | 0.315567 | 5807.39 | 3910.27 | 0.000127 |
HEAT PUMP COOLING MODE AIRLOOP F9 SE | 0.254950 | 4908.53 | 3236.15 | 0.000107 |
HEAT PUMP COOLING MODE AIRLOOP F9 NE | 0.250119 | 4818.08 | 3173.35 | 0.000105 |
HEAT PUMP COOLING MODE AIRLOOP F9 N1 | 0.175239 | 3567.04 | 2298.80 | 0.000078 |
HEAT PUMP COOLING MODE AIRLOOP F9 N2 | 0.174424 | 3554.79 | 2289.74 | 0.000078 |
HEAT PUMP COOLING MODE AIRLOOP F9 S1 | 0.171279 | 3560.38 | 2281.19 | 0.000078 |
HEAT PUMP COOLING MODE AIRLOOP F9 S2 | 0.171829 | 3568.40 | 2287.23 | 0.000078 |
HEAT PUMP COOLING MODE AIRLOOP T SW | 0.382080 | 6798.46 | 4655.54 | 0.000149 |
HEAT PUMP COOLING MODE AIRLOOP T NW | 0.381499 | 6785.88 | 4646.86 | 0.000148 |
HEAT PUMP COOLING MODE AIRLOOP T SE | 0.319003 | 5913.18 | 3973.93 | 0.000129 |
HEAT PUMP COOLING MODE AIRLOOP T NE | 0.307674 | 5693.60 | 3821.80 | 0.000124 |
HEAT PUMP COOLING MODE AIRLOOP T N1 | 0.229530 | 4423.93 | 2927.63 | 0.000097 |
HEAT PUMP COOLING MODE AIRLOOP T N2 | 0.229513 | 4423.44 | 2927.36 | 0.000097 |
HEAT PUMP COOLING MODE AIRLOOP T S1 | 0.248503 | 4699.16 | 3136.60 | 0.000103 |
HEAT PUMP COOLING MODE AIRLOOP T S2 | 0.249019 | 4706.44 | 3142.23 | 0.000103 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Supplemental Heating Coil Nominal Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
AIRLOOP G SW DXAC HEAT PUMP | 0.252480 | 0.252480 | 0.252480 | 0.252480 | 4608.67 | 4608.67 | 2729.40 | 1.00 |
AIRLOOP G NW DXAC HEAT PUMP | 0.258263 | 0.258263 | 0.258263 | 0.258263 | 4679.76 | 4679.76 | 2722.15 | 1.00 |
AIRLOOP OFFICE DXAC HEAT PUMP | 0.344380 | 0.344380 | 0.344380 | 0.344380 | 6206.62 | 6206.62 | 3402.45 | 1.00 |
AIRLOOP G NE DXAC HEAT PUMP | 0.204253 | 0.204253 | 0.204253 | 0.204253 | 3858.00 | 3858.00 | 2722.15 | 1.00 |
AIRLOOP G N1 DXAC HEAT PUMP | 0.130073 | 0.130073 | 0.130073 | 0.130073 | 2735.61 | 2735.61 | 1969.25 | 1.00 |
AIRLOOP G N2 DXAC HEAT PUMP | 0.128983 | 0.128983 | 0.128983 | 0.128983 | 2719.38 | 2719.38 | 1969.25 | 1.00 |
AIRLOOP G S1 DXAC HEAT PUMP | 0.127901 | 0.127901 | 0.127901 | 0.127901 | 2760.70 | 2760.70 | 1974.32 | 1.00 |
AIRLOOP G S2 DXAC HEAT PUMP | 0.133629 | 0.133629 | 0.133629 | 0.133629 | 2844.61 | 2844.61 | 1980.66 | 1.00 |
AIRLOOP F2 SW DXAC HEAT PUMP | 0.296815 | 0.296815 | 0.296815 | 0.296815 | 5325.85 | 5325.85 | 2721.67 | 1.00 |
AIRLOOP F2 NW DXAC HEAT PUMP | 0.302203 | 0.302203 | 0.302203 | 0.302203 | 5397.15 | 5397.15 | 2714.59 | 1.00 |
AIRLOOP F2 SE DXAC HEAT PUMP | 0.269410 | 0.269410 | 0.269410 | 0.269410 | 4908.14 | 4908.14 | 2740.79 | 1.00 |
AIRLOOP F2 NE DXAC HEAT PUMP | 0.242948 | 0.242948 | 0.242948 | 0.242948 | 4499.55 | 4499.55 | 2714.59 | 1.00 |
AIRLOOP F2 N1 DXAC HEAT PUMP | 0.158633 | 0.158633 | 0.158633 | 0.158633 | 3205.84 | 3205.84 | 1811.93 | 1.00 |
AIRLOOP F2 N2 DXAC HEAT PUMP | 0.157773 | 0.157773 | 0.157773 | 0.157773 | 3193.10 | 3193.10 | 1811.93 | 1.00 |
AIRLOOP F2 S1 DXAC HEAT PUMP | 0.157276 | 0.157276 | 0.157276 | 0.157276 | 3237.26 | 3237.26 | 1821.83 | 1.00 |
AIRLOOP F2 S2 DXAC HEAT PUMP | 0.159245 | 0.159245 | 0.159245 | 0.159245 | 3265.91 | 3265.91 | 1823.15 | 1.00 |
AIRLOOP F3 SW DXAC HEAT PUMP | 0.297920 | 0.297920 | 0.297920 | 0.297920 | 5394.79 | 5394.79 | 2745.26 | 1.00 |
AIRLOOP F3 NW DXAC HEAT PUMP | 0.303478 | 0.303478 | 0.303478 | 0.303478 | 5468.75 | 5468.75 | 2741.58 | 1.00 |
AIRLOOP F3 SE DXAC HEAT PUMP | 0.251132 | 0.251132 | 0.251132 | 0.251132 | 4696.98 | 4696.98 | 2747.49 | 1.00 |
AIRLOOP F3 NE DXAC HEAT PUMP | 0.244751 | 0.244751 | 0.244751 | 0.244751 | 4576.48 | 4576.48 | 2741.58 | 1.00 |
AIRLOOP F3 N1 DXAC HEAT PUMP | 0.161255 | 0.161255 | 0.161255 | 0.161255 | 3272.61 | 3272.61 | 1797.72 | 1.00 |
AIRLOOP F3 N2 DXAC HEAT PUMP | 0.160404 | 0.160404 | 0.160404 | 0.160404 | 3259.96 | 3259.96 | 1797.72 | 1.00 |
AIRLOOP F3 S1 DXAC HEAT PUMP | 0.160212 | 0.160212 | 0.160212 | 0.160212 | 3308.04 | 3308.04 | 1802.04 | 1.00 |
AIRLOOP F3 S2 DXAC HEAT PUMP | 0.161002 | 0.161002 | 0.161002 | 0.161002 | 3319.52 | 3319.52 | 1802.26 | 1.00 |
AIRLOOP F4 SW DXAC HEAT PUMP | 0.299129 | 0.299129 | 0.299129 | 0.299129 | 5451.62 | 5451.62 | 2802.27 | 1.00 |
AIRLOOP F4 NW DXAC HEAT PUMP | 0.304622 | 0.304622 | 0.304622 | 0.304622 | 5524.82 | 5524.82 | 2801.60 | 1.00 |
AIRLOOP F4 SE DXAC HEAT PUMP | 0.250010 | 0.250010 | 0.250010 | 0.250010 | 4718.56 | 4718.56 | 2802.52 | 1.00 |
AIRLOOP F4 NE DXAC HEAT PUMP | 0.245512 | 0.245512 | 0.245512 | 0.245512 | 4633.39 | 4633.39 | 2801.60 | 1.00 |
AIRLOOP F4 N1 DXAC HEAT PUMP | 0.163045 | 0.163045 | 0.163045 | 0.163045 | 3320.05 | 3320.05 | 1824.72 | 1.00 |
AIRLOOP F4 N2 DXAC HEAT PUMP | 0.162201 | 0.162201 | 0.162201 | 0.162201 | 3307.46 | 3307.46 | 1824.72 | 1.00 |
AIRLOOP F4 S1 DXAC HEAT PUMP | 0.161945 | 0.161945 | 0.161945 | 0.161945 | 3354.28 | 3354.28 | 1825.72 | 1.00 |
AIRLOOP F4 S2 DXAC HEAT PUMP | 0.162552 | 0.162552 | 0.162552 | 0.162552 | 3363.09 | 3363.09 | 1825.75 | 1.00 |
AIRLOOP M SW DXAC HEAT PUMP | 0.302131 | 0.302131 | 0.302131 | 0.302131 | 5526.84 | 5526.84 | 2837.60 | 1.00 |
AIRLOOP M NW DXAC HEAT PUMP | 0.307643 | 0.307643 | 0.307643 | 0.307643 | 5600.46 | 5600.46 | 2838.34 | 1.00 |
AIRLOOP M SE DXAC HEAT PUMP | 0.252508 | 0.252508 | 0.252508 | 0.252508 | 4785.39 | 4785.39 | 2837.63 | 1.00 |
AIRLOOP M NE DXAC HEAT PUMP | 0.248227 | 0.248227 | 0.248227 | 0.248227 | 4703.28 | 4703.28 | 2838.34 | 1.00 |
AIRLOOP M N1 DXAC HEAT PUMP | 0.166486 | 0.166486 | 0.166486 | 0.166486 | 3387.85 | 3387.85 | 1835.93 | 1.00 |
AIRLOOP M N2 DXAC HEAT PUMP | 0.165647 | 0.165647 | 0.165647 | 0.165647 | 3375.33 | 3375.33 | 1835.93 | 1.00 |
AIRLOOP M S1 DXAC HEAT PUMP | 0.165257 | 0.165257 | 0.165257 | 0.165257 | 3419.96 | 3419.96 | 1835.43 | 1.00 |
AIRLOOP M S2 DXAC HEAT PUMP | 0.165833 | 0.165833 | 0.165833 | 0.165833 | 3428.32 | 3428.32 | 1835.43 | 1.00 |
AIRLOOP F6 SW DXAC HEAT PUMP | 0.299663 | 0.299663 | 0.299663 | 0.299663 | 5523.95 | 5523.95 | 2926.03 | 1.00 |
AIRLOOP F6 NW DXAC HEAT PUMP | 0.305044 | 0.305044 | 0.305044 | 0.305044 | 5590.33 | 5590.33 | 2929.62 | 1.00 |
AIRLOOP F6 SE DXAC HEAT PUMP | 0.249858 | 0.249858 | 0.249858 | 0.249858 | 4772.72 | 4772.72 | 2926.04 | 1.00 |
AIRLOOP F6 NE DXAC HEAT PUMP | 0.245461 | 0.245461 | 0.245461 | 0.245461 | 4688.82 | 4688.82 | 2929.62 | 1.00 |
AIRLOOP F6 N1 DXAC HEAT PUMP | 0.164469 | 0.164469 | 0.164469 | 0.164469 | 3372.72 | 3372.72 | 1902.67 | 1.00 |
AIRLOOP F6 N2 DXAC HEAT PUMP | 0.163640 | 0.163640 | 0.163640 | 0.163640 | 3360.28 | 3360.28 | 1902.67 | 1.00 |
AIRLOOP F6 S1 DXAC HEAT PUMP | 0.163275 | 0.163275 | 0.163275 | 0.163275 | 3405.06 | 3405.06 | 1899.30 | 1.00 |
AIRLOOP F6 S2 DXAC HEAT PUMP | 0.163843 | 0.163843 | 0.163843 | 0.163843 | 3413.32 | 3413.32 | 1899.30 | 1.00 |
AIRLOOP F7 SW DXAC HEAT PUMP | 0.299171 | 0.299171 | 0.299171 | 0.299171 | 5540.59 | 5540.59 | 2989.08 | 1.00 |
AIRLOOP F7 NW DXAC HEAT PUMP | 0.304497 | 0.304497 | 0.304497 | 0.304497 | 5606.28 | 5606.28 | 2994.24 | 1.00 |
AIRLOOP F7 SE DXAC HEAT PUMP | 0.249176 | 0.249176 | 0.249176 | 0.249176 | 4785.33 | 4785.33 | 2989.08 | 1.00 |
AIRLOOP F7 NE DXAC HEAT PUMP | 0.244741 | 0.244741 | 0.244741 | 0.244741 | 4700.78 | 4700.78 | 2994.24 | 1.00 |
AIRLOOP F7 N1 DXAC HEAT PUMP | 0.164358 | 0.164358 | 0.164358 | 0.164358 | 3383.77 | 3383.77 | 1947.11 | 1.00 |
AIRLOOP F7 N2 DXAC HEAT PUMP | 0.163536 | 0.163536 | 0.163536 | 0.163536 | 3371.40 | 3371.40 | 1947.11 | 1.00 |
AIRLOOP F7 S1 DXAC HEAT PUMP | 0.163118 | 0.163118 | 0.163118 | 0.163118 | 3415.24 | 3415.24 | 1942.14 | 1.00 |
AIRLOOP F7 S2 DXAC HEAT PUMP | 0.163680 | 0.163680 | 0.163680 | 0.163680 | 3423.44 | 3423.44 | 1942.14 | 1.00 |
AIRLOOP F8 SW DXAC HEAT PUMP | 0.300045 | 0.300045 | 0.300045 | 0.300045 | 5574.45 | 5574.45 | 3053.65 | 1.00 |
AIRLOOP F8 NW DXAC HEAT PUMP | 0.305335 | 0.305335 | 0.305335 | 0.305335 | 5639.71 | 5639.71 | 3060.05 | 1.00 |
AIRLOOP F8 SE DXAC HEAT PUMP | 0.249844 | 0.249844 | 0.249844 | 0.249844 | 4815.18 | 4815.18 | 3053.65 | 1.00 |
AIRLOOP F8 NE DXAC HEAT PUMP | 0.245353 | 0.245353 | 0.245353 | 0.245353 | 4729.75 | 4729.75 | 3060.05 | 1.00 |
AIRLOOP F8 N1 DXAC HEAT PUMP | 0.165582 | 0.165582 | 0.165582 | 0.165582 | 3413.26 | 3413.26 | 1994.93 | 1.00 |
AIRLOOP F8 N2 DXAC HEAT PUMP | 0.164767 | 0.164767 | 0.164767 | 0.164767 | 3400.99 | 3400.99 | 1994.93 | 1.00 |
AIRLOOP F8 S1 DXAC HEAT PUMP | 0.164225 | 0.164225 | 0.164225 | 0.164225 | 3442.85 | 3442.85 | 1988.72 | 1.00 |
AIRLOOP F8 S2 DXAC HEAT PUMP | 0.164784 | 0.164784 | 0.164784 | 0.164784 | 3451.01 | 3451.01 | 1988.72 | 1.00 |
AIRLOOP F9 SW DXAC HEAT PUMP | 0.310054 | 0.310054 | 0.310054 | 0.310054 | 5733.40 | 5733.40 | 3215.62 | 1.00 |
AIRLOOP F9 NW DXAC HEAT PUMP | 0.315567 | 0.315567 | 0.315567 | 0.315567 | 5807.39 | 5807.39 | 3221.28 | 1.00 |
AIRLOOP F9 SE DXAC HEAT PUMP | 0.254950 | 0.254950 | 0.254950 | 0.254950 | 4908.53 | 4908.53 | 3215.62 | 1.00 |
AIRLOOP F9 NE DXAC HEAT PUMP | 0.250119 | 0.250119 | 0.250119 | 0.250119 | 4818.08 | 4818.08 | 3221.28 | 1.00 |
AIRLOOP F9 N1 DXAC HEAT PUMP | 0.175239 | 0.175239 | 0.175239 | 0.175239 | 3567.04 | 3567.04 | 2132.63 | 1.00 |
AIRLOOP F9 N2 DXAC HEAT PUMP | 0.174424 | 0.174424 | 0.174424 | 0.174424 | 3554.79 | 3554.79 | 2132.63 | 1.00 |
AIRLOOP F9 S1 DXAC HEAT PUMP | 0.171279 | 0.171279 | 0.171279 | 0.171279 | 3560.38 | 3560.38 | 2126.92 | 1.00 |
AIRLOOP F9 S2 DXAC HEAT PUMP | 0.171829 | 0.171829 | 0.171829 | 0.171829 | 3568.40 | 3568.40 | 2126.92 | 1.00 |
AIRLOOP T SW DXAC HEAT PUMP | 0.382080 | 0.382080 | 0.382080 | 0.382080 | 6798.46 | 6798.46 | 3713.56 | 1.00 |
AIRLOOP T NW DXAC HEAT PUMP | 0.381499 | 0.381499 | 0.381499 | 0.381499 | 6785.88 | 6785.88 | 3724.56 | 1.00 |
AIRLOOP T SE DXAC HEAT PUMP | 0.319003 | 0.319003 | 0.319003 | 0.319003 | 5913.18 | 5913.18 | 3713.56 | 1.00 |
AIRLOOP T NE DXAC HEAT PUMP | 0.307674 | 0.307674 | 0.307674 | 0.307674 | 5693.60 | 5693.60 | 3724.56 | 1.00 |
AIRLOOP T N1 DXAC HEAT PUMP | 0.229530 | 0.229530 | 0.229530 | 0.229530 | 4423.93 | 4423.93 | 2666.51 | 1.00 |
AIRLOOP T N2 DXAC HEAT PUMP | 0.229513 | 0.229513 | 0.229513 | 0.229513 | 4423.44 | 4423.44 | 2666.51 | 1.00 |
AIRLOOP T S1 DXAC HEAT PUMP | 0.248503 | 0.248503 | 0.248503 | 0.248503 | 4699.16 | 4699.16 | 2654.60 | 1.00 |
AIRLOOP T S2 DXAC HEAT PUMP | 0.249019 | 0.249019 | 0.249019 | 0.249019 | 4706.44 | 4706.44 | 2654.60 | 1.00 |
Maximum Flow Rate [m3/s] | |
AIRLOOP G SW SUPPLY FAN | 0.252480 |
AIRLOOP G NW SUPPLY FAN | 0.258263 |
AIRLOOP OFFICE SUPPLY FAN | 0.344380 |
AIRLOOP G NE SUPPLY FAN | 0.204253 |
AIRLOOP G N1 SUPPLY FAN | 0.130073 |
AIRLOOP G N2 SUPPLY FAN | 0.128983 |
AIRLOOP G S1 SUPPLY FAN | 0.127901 |
AIRLOOP G S2 SUPPLY FAN | 0.133629 |
AIRLOOP F2 SW SUPPLY FAN | 0.296815 |
AIRLOOP F2 NW SUPPLY FAN | 0.302203 |
AIRLOOP F2 SE SUPPLY FAN | 0.269410 |
AIRLOOP F2 NE SUPPLY FAN | 0.242948 |
AIRLOOP F2 N1 SUPPLY FAN | 0.158633 |
AIRLOOP F2 N2 SUPPLY FAN | 0.157773 |
AIRLOOP F2 S1 SUPPLY FAN | 0.157276 |
AIRLOOP F2 S2 SUPPLY FAN | 0.159245 |
AIRLOOP F3 SW SUPPLY FAN | 0.297920 |
AIRLOOP F3 NW SUPPLY FAN | 0.303478 |
AIRLOOP F3 SE SUPPLY FAN | 0.251132 |
AIRLOOP F3 NE SUPPLY FAN | 0.244751 |
AIRLOOP F3 N1 SUPPLY FAN | 0.161255 |
AIRLOOP F3 N2 SUPPLY FAN | 0.160404 |
AIRLOOP F3 S1 SUPPLY FAN | 0.160212 |
AIRLOOP F3 S2 SUPPLY FAN | 0.161002 |
AIRLOOP F4 SW SUPPLY FAN | 0.299129 |
AIRLOOP F4 NW SUPPLY FAN | 0.304622 |
AIRLOOP F4 SE SUPPLY FAN | 0.250010 |
AIRLOOP F4 NE SUPPLY FAN | 0.245512 |
AIRLOOP F4 N1 SUPPLY FAN | 0.163045 |
AIRLOOP F4 N2 SUPPLY FAN | 0.162201 |
AIRLOOP F4 S1 SUPPLY FAN | 0.161945 |
AIRLOOP F4 S2 SUPPLY FAN | 0.162552 |
AIRLOOP M SW SUPPLY FAN | 0.302131 |
AIRLOOP M NW SUPPLY FAN | 0.307643 |
AIRLOOP M SE SUPPLY FAN | 0.252508 |
AIRLOOP M NE SUPPLY FAN | 0.248227 |
AIRLOOP M N1 SUPPLY FAN | 0.166486 |
AIRLOOP M N2 SUPPLY FAN | 0.165647 |
AIRLOOP M S1 SUPPLY FAN | 0.165257 |
AIRLOOP M S2 SUPPLY FAN | 0.165833 |
AIRLOOP F6 SW SUPPLY FAN | 0.299663 |
AIRLOOP F6 NW SUPPLY FAN | 0.305044 |
AIRLOOP F6 SE SUPPLY FAN | 0.249858 |
AIRLOOP F6 NE SUPPLY FAN | 0.245461 |
AIRLOOP F6 N1 SUPPLY FAN | 0.164469 |
AIRLOOP F6 N2 SUPPLY FAN | 0.163640 |
AIRLOOP F6 S1 SUPPLY FAN | 0.163275 |
AIRLOOP F6 S2 SUPPLY FAN | 0.163843 |
AIRLOOP F7 SW SUPPLY FAN | 0.299171 |
AIRLOOP F7 NW SUPPLY FAN | 0.304497 |
AIRLOOP F7 SE SUPPLY FAN | 0.249176 |
AIRLOOP F7 NE SUPPLY FAN | 0.244741 |
AIRLOOP F7 N1 SUPPLY FAN | 0.164358 |
AIRLOOP F7 N2 SUPPLY FAN | 0.163536 |
AIRLOOP F7 S1 SUPPLY FAN | 0.163118 |
AIRLOOP F7 S2 SUPPLY FAN | 0.163680 |
AIRLOOP F8 SW SUPPLY FAN | 0.300045 |
AIRLOOP F8 NW SUPPLY FAN | 0.305335 |
AIRLOOP F8 SE SUPPLY FAN | 0.249844 |
AIRLOOP F8 NE SUPPLY FAN | 0.245353 |
AIRLOOP F8 N1 SUPPLY FAN | 0.165582 |
AIRLOOP F8 N2 SUPPLY FAN | 0.164767 |
AIRLOOP F8 S1 SUPPLY FAN | 0.164225 |
AIRLOOP F8 S2 SUPPLY FAN | 0.164784 |
AIRLOOP F9 SW SUPPLY FAN | 0.310054 |
AIRLOOP F9 NW SUPPLY FAN | 0.315567 |
AIRLOOP F9 SE SUPPLY FAN | 0.254950 |
AIRLOOP F9 NE SUPPLY FAN | 0.250119 |
AIRLOOP F9 N1 SUPPLY FAN | 0.175239 |
AIRLOOP F9 N2 SUPPLY FAN | 0.174424 |
AIRLOOP F9 S1 SUPPLY FAN | 0.171279 |
AIRLOOP F9 S2 SUPPLY FAN | 0.171829 |
AIRLOOP T SW SUPPLY FAN | 0.382080 |
AIRLOOP T NW SUPPLY FAN | 0.381499 |
AIRLOOP T SE SUPPLY FAN | 0.319003 |
AIRLOOP T NE SUPPLY FAN | 0.307674 |
AIRLOOP T N1 SUPPLY FAN | 0.229530 |
AIRLOOP T N2 SUPPLY FAN | 0.229513 |
AIRLOOP T S1 SUPPLY FAN | 0.248503 |
AIRLOOP T S2 SUPPLY FAN | 0.249019 |
Rated Air Flow Rate [m3/s] | Rated Heating Capacity [W] | Rated Water Flow Rate [m3/s] | |
HEAT PUMP HEATING MODE AIRLOOP G SW | 0.252480 | 4608.67 | 0.000101 |
HEAT PUMP HEATING MODE AIRLOOP G NW | 0.258263 | 4679.76 | 0.000102 |
HEAT PUMP HEATING MODE AIRLOOP OFFICE | 0.344380 | 6206.62 | 0.000136 |
HEAT PUMP HEATING MODE AIRLOOP G NE | 0.204253 | 3858.00 | 0.000084 |
HEAT PUMP HEATING MODE AIRLOOP G N1 | 0.130073 | 2735.61 | 0.000060 |
HEAT PUMP HEATING MODE AIRLOOP G N2 | 0.128983 | 2719.38 | 0.000059 |
HEAT PUMP HEATING MODE AIRLOOP G S1 | 0.127901 | 2760.70 | 0.000060 |
HEAT PUMP HEATING MODE AIRLOOP G S2 | 0.133629 | 2844.61 | 0.000062 |
HEAT PUMP HEATING MODE AIRLOOP F2 SW | 0.296815 | 5325.85 | 0.000116 |
HEAT PUMP HEATING MODE AIRLOOP F2 NW | 0.302203 | 5397.15 | 0.000118 |
HEAT PUMP HEATING MODE AIRLOOP F2 SE | 0.269410 | 4908.14 | 0.000107 |
HEAT PUMP HEATING MODE AIRLOOP F2 NE | 0.242948 | 4499.55 | 0.000098 |
HEAT PUMP HEATING MODE AIRLOOP F2 N1 | 0.158633 | 3205.84 | 0.000070 |
HEAT PUMP HEATING MODE AIRLOOP F2 N2 | 0.157773 | 3193.10 | 0.000070 |
HEAT PUMP HEATING MODE AIRLOOP F2 S1 | 0.157276 | 3237.26 | 0.000071 |
HEAT PUMP HEATING MODE AIRLOOP F2 S2 | 0.159245 | 3265.91 | 0.000071 |
HEAT PUMP HEATING MODE AIRLOOP F3 SW | 0.297920 | 5394.79 | 0.000118 |
HEAT PUMP HEATING MODE AIRLOOP F3 NW | 0.303478 | 5468.75 | 0.000119 |
HEAT PUMP HEATING MODE AIRLOOP F3 SE | 0.251132 | 4696.98 | 0.000103 |
HEAT PUMP HEATING MODE AIRLOOP F3 NE | 0.244751 | 4576.48 | 0.000100 |
HEAT PUMP HEATING MODE AIRLOOP F3 N1 | 0.161255 | 3272.61 | 0.000071 |
HEAT PUMP HEATING MODE AIRLOOP F3 N2 | 0.160404 | 3259.96 | 0.000071 |
HEAT PUMP HEATING MODE AIRLOOP F3 S1 | 0.160212 | 3308.04 | 0.000072 |
HEAT PUMP HEATING MODE AIRLOOP F3 S2 | 0.161002 | 3319.52 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F4 SW | 0.299129 | 5451.62 | 0.000119 |
HEAT PUMP HEATING MODE AIRLOOP F4 NW | 0.304622 | 5524.82 | 0.000121 |
HEAT PUMP HEATING MODE AIRLOOP F4 SE | 0.250010 | 4718.56 | 0.000103 |
HEAT PUMP HEATING MODE AIRLOOP F4 NE | 0.245512 | 4633.39 | 0.000101 |
HEAT PUMP HEATING MODE AIRLOOP F4 N1 | 0.163045 | 3320.05 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F4 N2 | 0.162201 | 3307.46 | 0.000072 |
HEAT PUMP HEATING MODE AIRLOOP F4 S1 | 0.161945 | 3354.28 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F4 S2 | 0.162552 | 3363.09 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP M SW | 0.302131 | 5526.84 | 0.000121 |
HEAT PUMP HEATING MODE AIRLOOP M NW | 0.307643 | 5600.46 | 0.000122 |
HEAT PUMP HEATING MODE AIRLOOP M SE | 0.252508 | 4785.39 | 0.000105 |
HEAT PUMP HEATING MODE AIRLOOP M NE | 0.248227 | 4703.28 | 0.000103 |
HEAT PUMP HEATING MODE AIRLOOP M N1 | 0.166486 | 3387.85 | 0.000074 |
HEAT PUMP HEATING MODE AIRLOOP M N2 | 0.165647 | 3375.33 | 0.000074 |
HEAT PUMP HEATING MODE AIRLOOP M S1 | 0.165257 | 3419.96 | 0.000075 |
HEAT PUMP HEATING MODE AIRLOOP M S2 | 0.165833 | 3428.32 | 0.000075 |
HEAT PUMP HEATING MODE AIRLOOP F6 SW | 0.299663 | 5523.95 | 0.000121 |
HEAT PUMP HEATING MODE AIRLOOP F6 NW | 0.305044 | 5590.33 | 0.000122 |
HEAT PUMP HEATING MODE AIRLOOP F6 SE | 0.249858 | 4772.72 | 0.000104 |
HEAT PUMP HEATING MODE AIRLOOP F6 NE | 0.245461 | 4688.82 | 0.000102 |
HEAT PUMP HEATING MODE AIRLOOP F6 N1 | 0.164469 | 3372.72 | 0.000074 |
HEAT PUMP HEATING MODE AIRLOOP F6 N2 | 0.163640 | 3360.28 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP F6 S1 | 0.163275 | 3405.06 | 0.000074 |
HEAT PUMP HEATING MODE AIRLOOP F6 S2 | 0.163843 | 3413.32 | 0.000075 |
HEAT PUMP HEATING MODE AIRLOOP F7 SW | 0.299171 | 5540.59 | 0.000121 |
HEAT PUMP HEATING MODE AIRLOOP F7 NW | 0.304497 | 5606.28 | 0.000122 |
HEAT PUMP HEATING MODE AIRLOOP F7 SE | 0.249176 | 4785.33 | 0.000105 |
HEAT PUMP HEATING MODE AIRLOOP F7 NE | 0.244741 | 4700.78 | 0.000103 |
HEAT PUMP HEATING MODE AIRLOOP F7 N1 | 0.164358 | 3383.77 | 0.000074 |
HEAT PUMP HEATING MODE AIRLOOP F7 N2 | 0.163536 | 3371.40 | 0.000074 |
HEAT PUMP HEATING MODE AIRLOOP F7 S1 | 0.163118 | 3415.24 | 0.000075 |
HEAT PUMP HEATING MODE AIRLOOP F7 S2 | 0.163680 | 3423.44 | 0.000075 |
HEAT PUMP HEATING MODE AIRLOOP F8 SW | 0.300045 | 5574.45 | 0.000122 |
HEAT PUMP HEATING MODE AIRLOOP F8 NW | 0.305335 | 5639.71 | 0.000123 |
HEAT PUMP HEATING MODE AIRLOOP F8 SE | 0.249844 | 4815.18 | 0.000105 |
HEAT PUMP HEATING MODE AIRLOOP F8 NE | 0.245353 | 4729.75 | 0.000103 |
HEAT PUMP HEATING MODE AIRLOOP F8 N1 | 0.165582 | 3413.26 | 0.000075 |
HEAT PUMP HEATING MODE AIRLOOP F8 N2 | 0.164767 | 3400.99 | 0.000074 |
HEAT PUMP HEATING MODE AIRLOOP F8 S1 | 0.164225 | 3442.85 | 0.000075 |
HEAT PUMP HEATING MODE AIRLOOP F8 S2 | 0.164784 | 3451.01 | 0.000075 |
HEAT PUMP HEATING MODE AIRLOOP F9 SW | 0.310054 | 5733.40 | 0.000125 |
HEAT PUMP HEATING MODE AIRLOOP F9 NW | 0.315567 | 5807.39 | 0.000127 |
HEAT PUMP HEATING MODE AIRLOOP F9 SE | 0.254950 | 4908.53 | 0.000107 |
HEAT PUMP HEATING MODE AIRLOOP F9 NE | 0.250119 | 4818.08 | 0.000105 |
HEAT PUMP HEATING MODE AIRLOOP F9 N1 | 0.175239 | 3567.04 | 0.000078 |
HEAT PUMP HEATING MODE AIRLOOP F9 N2 | 0.174424 | 3554.79 | 0.000078 |
HEAT PUMP HEATING MODE AIRLOOP F9 S1 | 0.171279 | 3560.38 | 0.000078 |
HEAT PUMP HEATING MODE AIRLOOP F9 S2 | 0.171829 | 3568.40 | 0.000078 |
HEAT PUMP HEATING MODE AIRLOOP T SW | 0.382080 | 6798.46 | 0.000149 |
HEAT PUMP HEATING MODE AIRLOOP T NW | 0.381499 | 6785.88 | 0.000148 |
HEAT PUMP HEATING MODE AIRLOOP T SE | 0.319003 | 5913.18 | 0.000129 |
HEAT PUMP HEATING MODE AIRLOOP T NE | 0.307674 | 5693.60 | 0.000124 |
HEAT PUMP HEATING MODE AIRLOOP T N1 | 0.229530 | 4423.93 | 0.000097 |
HEAT PUMP HEATING MODE AIRLOOP T N2 | 0.229513 | 4423.44 | 0.000097 |
HEAT PUMP HEATING MODE AIRLOOP T S1 | 0.248503 | 4699.16 | 0.000103 |
HEAT PUMP HEATING MODE AIRLOOP T S2 | 0.249019 | 4706.44 | 0.000103 |
Nominal Capacity [W] | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW | 2729.40 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW | 2722.15 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE | 3402.45 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE | 2722.15 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 | 1969.25 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 | 1969.25 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 | 1974.32 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 | 1980.66 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW | 2721.67 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW | 2714.59 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE | 2740.79 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE | 2714.59 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 | 1811.93 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 | 1811.93 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 | 1821.83 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 | 1823.15 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW | 2745.26 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW | 2741.58 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE | 2747.49 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE | 2741.58 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 | 1797.72 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 | 1797.72 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 | 1802.04 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 | 1802.26 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW | 2802.27 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW | 2801.60 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE | 2802.52 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE | 2801.60 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 | 1824.72 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 | 1824.72 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 | 1825.72 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 | 1825.75 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW | 2837.60 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW | 2838.34 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE | 2837.63 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE | 2838.34 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 | 1835.93 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 | 1835.93 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 | 1835.43 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 | 1835.43 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW | 2926.03 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW | 2929.62 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE | 2926.04 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE | 2929.62 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 | 1902.67 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 | 1902.67 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 | 1899.30 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 | 1899.30 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW | 2989.08 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW | 2994.24 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE | 2989.08 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE | 2994.24 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 | 1947.11 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 | 1947.11 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 | 1942.14 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 | 1942.14 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW | 3053.65 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW | 3060.05 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE | 3053.65 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE | 3060.05 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 | 1994.93 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 | 1994.93 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 | 1988.72 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 | 1988.72 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW | 3215.62 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW | 3221.28 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE | 3215.62 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE | 3221.28 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 | 2132.63 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 | 2132.63 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 | 2126.92 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 | 2126.92 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW | 3713.56 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW | 3724.56 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE | 3713.56 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE | 3724.56 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 | 2666.51 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 | 2666.51 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 | 2654.60 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 | 2654.60 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
SHWSYS1 | 0.000289 | 0.325214 |
SINGLE WATER PLANT LOOP | 0.007568 | 8.51 |
Design Water Flow Rate [m3/s] | |
CENTRAL BOILER | 0.007568 |
Use Side Design Flow Rate [m3/s] | |
SHWSYS1 WATER HEATER | 0.000289 |
Design Water Flow Rate [m3/s] | Fan Power at Design Air Flow Rate [W] | Design Air Flow Rate [m3/s] | U-Factor Times Area Value at Design Air Flow Rate [W/C] | |
CENTRAL TOWER | 0.007568 | 3653.19 | 9.65 | 11298.37 |
Rated Flow Rate [m3/s] | Rated Power Consumption [W] | |
SHWSYS1 PUMP | 0.000289 | 36.93 |
PLANT CIRC PUMP | 0.007568 | 2416.67 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:57
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW3 | |
G WWALL SWA | GWINDOW2 | |
G NWALL NWA | GWINDOW4 | |
G WWALL NWA | GWINDOW6 | |
G SWALL SEA | GWINDOW1 | |
G EWALL SEA | GWINDOW8 | |
G NWALL NEA | GWINDOW5 | |
G EWALL NEA | GWINDOW7 | |
G NWALL N1A | GWINDOW9 | |
G NWALL N2A | GWINDOW10 | |
G SWALL S1A | GWINDOW11 | |
G SWALL S2A | GWINDOW12 | |
G WWALL C | GWINDOW13 | |
G EWALL C | ENTRANCE DOOR | |
F2 WWALL SWA | F2WINDOW2 | |
F2 SWALL SWA | F2WINDOW3 | |
F2 NWALL NWA | F2WINDOW4 | |
F2 WWALL NWA | F2WINDOW6 | |
F2 EWALL SEA | F2WINDOW8 | |
F2 SWALL SEA | F2WINDOW1 | |
F2 NWALL NEA | F2WINDOW5 | |
F2 EWALL NEA | F2WINDOW7 | |
F2 NWALL N1A | F2WINDOW9 | |
F2 NWALL N2A | F2WINDOW10 | |
F2 SWALL S1A | F2WINDOW11 | |
F2 SWALL S2A | F2WINDOW12 | |
F2 WWALL C | F2WINDOW13 | |
F2 EWALL C | F2WINDOW14 | |
F3 WWALL SWA | F3WINDOW2 | |
F3 SWALL SWA | F3WINDOW3 | |
F3 NWALL NWA | F3WINDOW4 | |
F3 WWALL NWA | F3WINDOW6 | |
F3 EWALL SEA | F3WINDOW8 | |
F3 SWALL SEA | F3WINDOW1 | |
F3 NWALL NEA | F3WINDOW5 | |
F3 EWALL NEA | F3WINDOW7 | |
F3 NWALL N1A | F3WINDOW9 | |
F3 NWALL N2A | F3WINDOW10 | |
F3 SWALL S1A | F3WINDOW11 | |
F3 SWALL S2A | F3WINDOW12 | |
F3 WWALL C | F3WINDOW13 | |
F3 EWALL C | F3WINDOW14 | |
F4 WWALL SWA | F4WINDOW2 | |
F4 SWALL SWA | F4WINDOW3 | |
F4 NWALL NWA | F4WINDOW4 | |
F4 WWALL NWA | F4WINDOW6 | |
F4 EWALL SEA | F4WINDOW8 | |
F4 SWALL SEA | F4WINDOW1 | |
F4 NWALL NEA | F4WINDOW5 | |
F4 EWALL NEA | F4WINDOW7 | |
F4 NWALL N1A | F4WINDOW9 | |
F4 NWALL N2A | F4WINDOW10 | |
F4 SWALL S1A | F4WINDOW11 | |
F4 SWALL S2A | F4WINDOW12 | |
F4 WWALL C | F4WINDOW13 | |
F4 EWALL C | F4WINDOW14 | |
M WWALL SWA | MWINDOW2 | |
M SWALL SWA | MWINDOW3 | |
M NWALL NWA | MWINDOW4 | |
M WWALL NWA | MWINDOW6 | |
M EWALL SEA | MWINDOW8 | |
M SWALL SEA | MWINDOW1 | |
M NWALL NEA | MWINDOW5 | |
M EWALL NEA | MWINDOW7 | |
M NWALL N1A | MWINDOW9 | |
M NWALL N2A | MWINDOW10 | |
M SWALL S1A | MWINDOW11 | |
M SWALL S2A | MWINDOW12 | |
M WWALL C | MWINDOW13 | |
M EWALL C | MWINDOW14 | |
F6 WWALL SWA | F6WINDOW2 | |
F6 SWALL SWA | F6WINDOW3 | |
F6 NWALL NWA | F6WINDOW4 | |
F6 WWALL NWA | F6WINDOW6 | |
F6 EWALL SEA | F6WINDOW8 | |
F6 SWALL SEA | F6WINDOW1 | |
F6 NWALL NEA | F6WINDOW5 | |
F6 EWALL NEA | F6WINDOW7 | |
F6 NWALL N1A | F6WINDOW9 | |
F6 NWALL N2A | F6WINDOW10 | |
F6 SWALL S1A | F6WINDOW11 | |
F6 SWALL S2A | F6WINDOW12 | |
F6 WWALL C | F6WINDOW13 | |
F6 EWALL C | F6WINDOW14 | |
F7 WWALL SWA | F7WINDOW2 | |
F7 SWALL SWA | F7WINDOW3 | |
F7 NWALL NWA | F7WINDOW4 | |
F7 WWALL NWA | F7WINDOW6 | |
F7 EWALL SEA | F7WINDOW8 | |
F7 SWALL SEA | F7WINDOW1 | |
F7 NWALL NEA | F7WINDOW5 | |
F7 EWALL NEA | F7WINDOW7 | |
F7 NWALL N1A | F7WINDOW9 | |
F7 NWALL N2A | F7WINDOW10 | |
F7 SWALL S1A | F7WINDOW11 | |
F7 SWALL S2A | F7WINDOW12 | |
F7 WWALL C | F7WINDOW13 | |
F7 EWALL C | F7WINDOW14 | |
F8 WWALL SWA | F8WINDOW2 | |
F8 SWALL SWA | F8WINDOW3 | |
F8 NWALL NWA | F8WINDOW4 | |
F8 WWALL NWA | F8WINDOW6 | |
F8 EWALL SEA | F8WINDOW8 | |
F8 SWALL SEA | F8WINDOW1 | |
F8 NWALL NEA | F8WINDOW5 | |
F8 EWALL NEA | F8WINDOW7 | |
F8 NWALL N1A | F8WINDOW9 | |
F8 NWALL N2A | F8WINDOW10 | |
F8 SWALL S1A | F8WINDOW11 | |
F8 SWALL S2A | F8WINDOW12 | |
F8 WWALL C | F8WINDOW13 | |
F8 EWALL C | F8WINDOW14 | |
F9 WWALL SWA | F9WINDOW2 | |
F9 SWALL SWA | F9WINDOW3 | |
F9 NWALL NWA | F9WINDOW4 | |
F9 WWALL NWA | F9WINDOW6 | |
F9 EWALL SEA | F9WINDOW8 | |
F9 SWALL SEA | F9WINDOW1 | |
F9 NWALL NEA | F9WINDOW5 | |
F9 EWALL NEA | F9WINDOW7 | |
F9 NWALL N1A | F9WINDOW9 | |
F9 NWALL N2A | F9WINDOW10 | |
F9 SWALL S1A | F9WINDOW11 | |
F9 SWALL S2A | F9WINDOW12 | |
F9 WWALL C | F9WINDOW13 | |
F9 EWALL C | F9WINDOW14 | |
T WWALL SWA | TWINDOW2 | |
T SWALL SWA | TWINDOW3 | |
T NWALL NWA | TWINDOW4 | |
T WWALL NWA | TWINDOW6 | |
T EWALL SEA | TWINDOW8 | |
T SWALL SEA | TWINDOW1 | |
T NWALL NEA | TWINDOW5 | |
T EWALL NEA | TWINDOW7 | |
T NWALL N1A | TWINDOW9 | |
T NWALL N2A | TWINDOW10 | |
T SWALL S1A | TWINDOW11 | |
T SWALL S2A | TWINDOW12 | |
T WWALL C | TWINDOW13 | |
T EWALL C | TWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:57
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.37 | 10.50 |
February | 22.71 | 12.77 |
March | 23.10 | 16.20 |
April | 23.77 | 20.49 |
May | 24.25 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.37 | 26.44 |
October | 23.92 | 20.33 |
November | 23.51 | 17.10 |
December | 22.71 | 12.54 |
Annual Sum or Average | 23.66 | 20.36 |
Minimum of Months | 22.37 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.98 | 10.50 |
February | 22.44 | 12.77 |
March | 22.91 | 16.20 |
April | 23.74 | 20.49 |
May | 24.27 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.36 | 26.44 |
October | 23.78 | 20.33 |
November | 23.16 | 17.10 |
December | 22.30 | 12.54 |
Annual Sum or Average | 23.52 | 20.36 |
Minimum of Months | 21.98 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.74 | 10.50 |
February | 23.12 | 12.77 |
March | 23.57 | 16.20 |
April | 24.12 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.40 | 26.44 |
October | 24.13 | 20.33 |
November | 23.77 | 17.10 |
December | 23.03 | 12.54 |
Annual Sum or Average | 23.87 | 20.36 |
Minimum of Months | 22.74 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.91 | 10.50 |
February | 22.36 | 12.77 |
March | 22.84 | 16.20 |
April | 23.71 | 20.49 |
May | 24.26 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.37 | 26.44 |
October | 23.76 | 20.33 |
November | 23.11 | 17.10 |
December | 22.22 | 12.54 |
Annual Sum or Average | 23.48 | 20.36 |
Minimum of Months | 21.91 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.90 | 10.50 |
February | 22.30 | 12.77 |
March | 22.74 | 16.20 |
April | 23.62 | 20.49 |
May | 24.22 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.36 | 26.44 |
October | 23.69 | 20.33 |
November | 23.03 | 17.10 |
December | 22.19 | 12.54 |
Annual Sum or Average | 23.44 | 20.36 |
Minimum of Months | 21.90 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.89 | 10.50 |
February | 22.30 | 12.77 |
March | 22.73 | 16.20 |
April | 23.61 | 20.49 |
May | 24.22 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.36 | 26.44 |
October | 23.68 | 20.33 |
November | 23.03 | 17.10 |
December | 22.19 | 12.54 |
Annual Sum or Average | 23.44 | 20.36 |
Minimum of Months | 21.89 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.37 | 10.50 |
February | 22.66 | 12.77 |
March | 23.03 | 16.20 |
April | 23.70 | 20.49 |
May | 24.22 | 24.03 |
June | 24.39 | 27.02 |
July | 24.41 | 28.27 |
August | 24.46 | 28.21 |
September | 24.44 | 26.44 |
October | 23.92 | 20.33 |
November | 23.51 | 17.10 |
December | 22.71 | 12.54 |
Annual Sum or Average | 23.66 | 20.36 |
Minimum of Months | 22.37 | 10.50 |
Maximum of Months | 24.46 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.41 | 10.50 |
February | 22.69 | 12.77 |
March | 23.08 | 16.20 |
April | 23.74 | 20.49 |
May | 24.23 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.45 | 28.21 |
September | 24.43 | 26.44 |
October | 23.94 | 20.33 |
November | 23.55 | 17.10 |
December | 22.74 | 12.54 |
Annual Sum or Average | 23.68 | 20.36 |
Minimum of Months | 22.41 | 10.50 |
Maximum of Months | 24.45 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.10 | 10.50 |
February | 20.06 | 12.77 |
March | 21.50 | 16.20 |
April | 23.31 | 20.49 |
May | 24.83 | 24.03 |
June | 26.52 | 27.02 |
July | 27.04 | 28.27 |
August | 27.03 | 28.21 |
September | 26.48 | 26.44 |
October | 23.68 | 20.33 |
November | 22.08 | 17.10 |
December | 19.99 | 12.54 |
Annual Sum or Average | 23.48 | 20.36 |
Minimum of Months | 19.10 | 10.50 |
Maximum of Months | 27.04 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F2 SW APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.70 | 10.50 |
February | 23.07 | 12.77 |
March | 23.53 | 16.20 |
April | 24.10 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.22 | 20.33 |
November | 23.92 | 17.10 |
December | 23.14 | 12.54 |
Annual Sum or Average | 23.89 | 20.36 |
Minimum of Months | 22.70 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F2 NW APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.15 | 10.50 |
February | 22.71 | 12.77 |
March | 23.26 | 16.20 |
April | 24.06 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.08 | 20.33 |
November | 23.52 | 17.10 |
December | 22.54 | 12.54 |
Annual Sum or Average | 23.69 | 20.36 |
Minimum of Months | 22.15 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F2 SE APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.76 | 10.50 |
February | 23.12 | 12.77 |
March | 23.62 | 16.20 |
April | 24.16 | 20.49 |
May | 24.37 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.39 | 26.44 |
October | 24.26 | 20.33 |
November | 23.96 | 17.10 |
December | 23.19 | 12.54 |
Annual Sum or Average | 23.92 | 20.36 |
Minimum of Months | 22.76 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F2 NE APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.05 | 10.50 |
February | 22.62 | 12.77 |
March | 23.19 | 16.20 |
April | 24.03 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.07 | 20.33 |
November | 23.46 | 17.10 |
December | 22.42 | 12.54 |
Annual Sum or Average | 23.65 | 20.36 |
Minimum of Months | 22.05 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F2 N1 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.10 | 10.50 |
February | 22.62 | 12.77 |
March | 23.17 | 16.20 |
April | 24.01 | 20.49 |
May | 24.35 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.04 | 20.33 |
November | 23.47 | 17.10 |
December | 22.48 | 12.54 |
Annual Sum or Average | 23.66 | 20.36 |
Minimum of Months | 22.10 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F2 N2 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.10 | 10.50 |
February | 22.61 | 12.77 |
March | 23.17 | 16.20 |
April | 24.01 | 20.49 |
May | 24.35 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.04 | 20.33 |
November | 23.47 | 17.10 |
December | 22.47 | 12.54 |
Annual Sum or Average | 23.65 | 20.36 |
Minimum of Months | 22.10 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F2 S1 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.82 | 10.50 |
February | 23.10 | 12.77 |
March | 23.55 | 16.20 |
April | 24.08 | 20.49 |
May | 24.35 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.44 | 28.21 |
September | 24.44 | 26.44 |
October | 24.26 | 20.33 |
November | 24.01 | 17.10 |
December | 23.24 | 12.54 |
Annual Sum or Average | 23.93 | 20.36 |
Minimum of Months | 22.82 | 10.50 |
Maximum of Months | 24.44 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F2 S2 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.83 | 10.50 |
February | 23.11 | 12.77 |
March | 23.57 | 16.20 |
April | 24.09 | 20.49 |
May | 24.35 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.44 | 28.21 |
September | 24.43 | 26.44 |
October | 24.26 | 20.33 |
November | 24.01 | 17.10 |
December | 23.26 | 12.54 |
Annual Sum or Average | 23.93 | 20.36 |
Minimum of Months | 22.83 | 10.50 |
Maximum of Months | 24.44 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F2 CORRIDOR
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.80 | 10.50 |
February | 23.41 | 12.77 |
March | 24.30 | 16.20 |
April | 25.31 | 20.49 |
May | 26.00 | 24.03 |
June | 26.49 | 27.02 |
July | 26.65 | 28.27 |
August | 26.63 | 28.21 |
September | 26.47 | 26.44 |
October | 25.54 | 20.33 |
November | 24.76 | 17.10 |
December | 23.39 | 12.54 |
Annual Sum or Average | 25.15 | 20.36 |
Minimum of Months | 22.80 | 10.50 |
Maximum of Months | 26.65 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F3 SW APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.73 | 10.50 |
February | 23.11 | 12.77 |
March | 23.57 | 16.20 |
April | 24.14 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.25 | 20.33 |
November | 23.97 | 17.10 |
December | 23.21 | 12.54 |
Annual Sum or Average | 23.91 | 20.36 |
Minimum of Months | 22.73 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F3 NW APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.18 | 10.50 |
February | 22.76 | 12.77 |
March | 23.31 | 16.20 |
April | 24.09 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.12 | 20.33 |
November | 23.57 | 17.10 |
December | 22.58 | 12.54 |
Annual Sum or Average | 23.72 | 20.36 |
Minimum of Months | 22.18 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F3 SE APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.67 | 10.50 |
February | 23.06 | 12.77 |
March | 23.55 | 16.20 |
April | 24.14 | 20.49 |
May | 24.37 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.41 | 28.21 |
September | 24.39 | 26.44 |
October | 24.26 | 20.33 |
November | 23.94 | 17.10 |
December | 23.15 | 12.54 |
Annual Sum or Average | 23.90 | 20.36 |
Minimum of Months | 22.67 | 10.50 |
Maximum of Months | 24.41 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F3 NE APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.08 | 10.50 |
February | 22.67 | 12.77 |
March | 23.24 | 16.20 |
April | 24.08 | 20.49 |
May | 24.37 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.11 | 20.33 |
November | 23.52 | 17.10 |
December | 22.46 | 12.54 |
Annual Sum or Average | 23.68 | 20.36 |
Minimum of Months | 22.08 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F3 N1 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.16 | 10.50 |
February | 22.70 | 12.77 |
March | 23.27 | 16.20 |
April | 24.08 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.10 | 20.33 |
November | 23.57 | 17.10 |
December | 22.57 | 12.54 |
Annual Sum or Average | 23.70 | 20.36 |
Minimum of Months | 22.16 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F3 N2 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.16 | 10.50 |
February | 22.70 | 12.77 |
March | 23.26 | 16.20 |
April | 24.08 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.10 | 20.33 |
November | 23.56 | 17.10 |
December | 22.56 | 12.54 |
Annual Sum or Average | 23.70 | 20.36 |
Minimum of Months | 22.16 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F3 S1 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.92 | 10.50 |
February | 23.18 | 12.77 |
March | 23.64 | 16.20 |
April | 24.14 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.44 | 28.21 |
September | 24.44 | 26.44 |
October | 24.30 | 20.33 |
November | 24.08 | 17.10 |
December | 23.37 | 12.54 |
Annual Sum or Average | 23.98 | 20.36 |
Minimum of Months | 22.92 | 10.50 |
Maximum of Months | 24.44 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F3 S2 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.92 | 10.50 |
February | 23.18 | 12.77 |
March | 23.65 | 16.20 |
April | 24.14 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.44 | 28.21 |
September | 24.44 | 26.44 |
October | 24.30 | 20.33 |
November | 24.08 | 17.10 |
December | 23.37 | 12.54 |
Annual Sum or Average | 23.98 | 20.36 |
Minimum of Months | 22.92 | 10.50 |
Maximum of Months | 24.44 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F3 CORRIDOR
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.17 | 10.50 |
February | 23.79 | 12.77 |
March | 24.64 | 16.20 |
April | 25.61 | 20.49 |
May | 26.23 | 24.03 |
June | 26.55 | 27.02 |
July | 26.67 | 28.27 |
August | 26.65 | 28.21 |
September | 26.51 | 26.44 |
October | 25.82 | 20.33 |
November | 25.11 | 17.10 |
December | 23.78 | 12.54 |
Annual Sum or Average | 25.38 | 20.36 |
Minimum of Months | 23.17 | 10.50 |
Maximum of Months | 26.67 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F4 SW APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.74 | 10.50 |
February | 23.13 | 12.77 |
March | 23.54 | 16.20 |
April | 24.13 | 20.49 |
May | 24.37 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.25 | 20.33 |
November | 23.96 | 17.10 |
December | 23.20 | 12.54 |
Annual Sum or Average | 23.91 | 20.36 |
Minimum of Months | 22.74 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F4 NW APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.20 | 10.50 |
February | 22.79 | 12.77 |
March | 23.29 | 16.20 |
April | 24.09 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.13 | 20.33 |
November | 23.57 | 17.10 |
December | 22.58 | 12.54 |
Annual Sum or Average | 23.72 | 20.36 |
Minimum of Months | 22.20 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F4 SE APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.65 | 10.50 |
February | 23.05 | 12.77 |
March | 23.51 | 16.20 |
April | 24.12 | 20.49 |
May | 24.37 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.41 | 28.21 |
September | 24.40 | 26.44 |
October | 24.25 | 20.33 |
November | 23.92 | 17.10 |
December | 23.12 | 12.54 |
Annual Sum or Average | 23.89 | 20.36 |
Minimum of Months | 22.65 | 10.50 |
Maximum of Months | 24.41 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F4 NE APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.09 | 10.50 |
February | 22.70 | 12.77 |
March | 23.22 | 16.20 |
April | 24.07 | 20.49 |
May | 24.37 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.12 | 20.33 |
November | 23.52 | 17.10 |
December | 22.45 | 12.54 |
Annual Sum or Average | 23.68 | 20.36 |
Minimum of Months | 22.09 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F4 N1 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.20 | 10.50 |
February | 22.75 | 12.77 |
March | 23.28 | 16.20 |
April | 24.08 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.12 | 20.33 |
November | 23.59 | 17.10 |
December | 22.59 | 12.54 |
Annual Sum or Average | 23.72 | 20.36 |
Minimum of Months | 22.20 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F4 N2 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.19 | 10.50 |
February | 22.75 | 12.77 |
March | 23.28 | 16.20 |
April | 24.08 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.12 | 20.33 |
November | 23.58 | 17.10 |
December | 22.58 | 12.54 |
Annual Sum or Average | 23.71 | 20.36 |
Minimum of Months | 22.19 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F4 S1 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.96 | 10.50 |
February | 23.21 | 12.77 |
March | 23.64 | 16.20 |
April | 24.14 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.44 | 28.21 |
September | 24.44 | 26.44 |
October | 24.31 | 20.33 |
November | 24.09 | 17.10 |
December | 23.38 | 12.54 |
Annual Sum or Average | 23.98 | 20.36 |
Minimum of Months | 22.96 | 10.50 |
Maximum of Months | 24.44 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F4 S2 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.96 | 10.50 |
February | 23.21 | 12.77 |
March | 23.64 | 16.20 |
April | 24.14 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.44 | 28.21 |
September | 24.44 | 26.44 |
October | 24.31 | 20.33 |
November | 24.09 | 17.10 |
December | 23.38 | 12.54 |
Annual Sum or Average | 23.98 | 20.36 |
Minimum of Months | 22.96 | 10.50 |
Maximum of Months | 24.44 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F4 CORRIDOR
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.30 | 10.50 |
February | 23.92 | 12.77 |
March | 24.75 | 16.20 |
April | 25.73 | 20.49 |
May | 26.33 | 24.03 |
June | 26.63 | 27.02 |
July | 26.74 | 28.27 |
August | 26.72 | 28.21 |
September | 26.59 | 26.44 |
October | 25.94 | 20.33 |
November | 25.23 | 17.10 |
December | 23.91 | 12.54 |
Annual Sum or Average | 25.49 | 20.36 |
Minimum of Months | 23.30 | 10.50 |
Maximum of Months | 26.74 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.71 | 10.50 |
February | 23.11 | 12.77 |
March | 23.51 | 16.20 |
April | 24.11 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.25 | 20.33 |
November | 23.95 | 17.10 |
December | 23.18 | 12.54 |
Annual Sum or Average | 23.90 | 20.36 |
Minimum of Months | 22.71 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.19 | 10.50 |
February | 22.78 | 12.77 |
March | 23.27 | 16.20 |
April | 24.07 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.13 | 20.33 |
November | 23.57 | 17.10 |
December | 22.57 | 12.54 |
Annual Sum or Average | 23.71 | 20.36 |
Minimum of Months | 22.19 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.62 | 10.50 |
February | 23.03 | 12.77 |
March | 23.47 | 16.20 |
April | 24.10 | 20.49 |
May | 24.37 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.41 | 28.21 |
September | 24.40 | 26.44 |
October | 24.25 | 20.33 |
November | 23.91 | 17.10 |
December | 23.09 | 12.54 |
Annual Sum or Average | 23.87 | 20.36 |
Minimum of Months | 22.62 | 10.50 |
Maximum of Months | 24.41 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.08 | 10.50 |
February | 22.69 | 12.77 |
March | 23.20 | 16.20 |
April | 24.05 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.12 | 20.33 |
November | 23.51 | 17.10 |
December | 22.45 | 12.54 |
Annual Sum or Average | 23.67 | 20.36 |
Minimum of Months | 22.08 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.20 | 10.50 |
February | 22.76 | 12.77 |
March | 23.27 | 16.20 |
April | 24.08 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.12 | 20.33 |
November | 23.59 | 17.10 |
December | 22.59 | 12.54 |
Annual Sum or Average | 23.72 | 20.36 |
Minimum of Months | 22.20 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.20 | 10.50 |
February | 22.75 | 12.77 |
March | 23.27 | 16.20 |
April | 24.08 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.12 | 20.33 |
November | 23.59 | 17.10 |
December | 22.58 | 12.54 |
Annual Sum or Average | 23.71 | 20.36 |
Minimum of Months | 22.20 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.95 | 10.50 |
February | 23.20 | 12.77 |
March | 23.62 | 16.20 |
April | 24.13 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.44 | 28.21 |
September | 24.43 | 26.44 |
October | 24.31 | 20.33 |
November | 24.09 | 17.10 |
December | 23.38 | 12.54 |
Annual Sum or Average | 23.98 | 20.36 |
Minimum of Months | 22.95 | 10.50 |
Maximum of Months | 24.44 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.95 | 10.50 |
February | 23.20 | 12.77 |
March | 23.62 | 16.20 |
April | 24.13 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.43 | 28.21 |
September | 24.43 | 26.44 |
October | 24.31 | 20.33 |
November | 24.08 | 17.10 |
December | 23.37 | 12.54 |
Annual Sum or Average | 23.98 | 20.36 |
Minimum of Months | 22.95 | 10.50 |
Maximum of Months | 24.43 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.85 | 10.50 |
February | 24.47 | 12.77 |
March | 25.27 | 16.20 |
April | 26.25 | 20.49 |
May | 26.86 | 24.03 |
June | 27.15 | 27.02 |
July | 27.26 | 28.27 |
August | 27.24 | 28.21 |
September | 27.11 | 26.44 |
October | 26.48 | 20.33 |
November | 25.77 | 17.10 |
December | 24.45 | 12.54 |
Annual Sum or Average | 26.02 | 20.36 |
Minimum of Months | 23.85 | 10.50 |
Maximum of Months | 27.26 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F6 SW APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.61 | 10.50 |
February | 23.04 | 12.77 |
March | 23.42 | 16.20 |
April | 24.07 | 20.49 |
May | 24.36 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.23 | 20.33 |
November | 23.90 | 17.10 |
December | 23.10 | 12.54 |
Annual Sum or Average | 23.86 | 20.36 |
Minimum of Months | 22.61 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F6 NW APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.13 | 10.50 |
February | 22.72 | 12.77 |
March | 23.19 | 16.20 |
April | 24.03 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.09 | 20.33 |
November | 23.51 | 17.10 |
December | 22.49 | 12.54 |
Annual Sum or Average | 23.68 | 20.36 |
Minimum of Months | 22.13 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F6 SE APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.52 | 10.50 |
February | 22.96 | 12.77 |
March | 23.38 | 16.20 |
April | 24.05 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.41 | 28.21 |
September | 24.40 | 26.44 |
October | 24.23 | 20.33 |
November | 23.86 | 17.10 |
December | 23.00 | 12.54 |
Annual Sum or Average | 23.83 | 20.36 |
Minimum of Months | 22.52 | 10.50 |
Maximum of Months | 24.41 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F6 NE APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.03 | 10.50 |
February | 22.64 | 12.77 |
March | 23.11 | 16.20 |
April | 24.00 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.08 | 20.33 |
November | 23.46 | 17.10 |
December | 22.38 | 12.54 |
Annual Sum or Average | 23.64 | 20.36 |
Minimum of Months | 22.03 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F6 N1 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.15 | 10.50 |
February | 22.70 | 12.77 |
March | 23.19 | 16.20 |
April | 24.03 | 20.49 |
May | 24.35 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.09 | 20.33 |
November | 23.53 | 17.10 |
December | 22.52 | 12.54 |
Annual Sum or Average | 23.68 | 20.36 |
Minimum of Months | 22.15 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F6 N2 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.14 | 10.50 |
February | 22.70 | 12.77 |
March | 23.18 | 16.20 |
April | 24.03 | 20.49 |
May | 24.35 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.08 | 20.33 |
November | 23.53 | 17.10 |
December | 22.51 | 12.54 |
Annual Sum or Average | 23.68 | 20.36 |
Minimum of Months | 22.14 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F6 S1 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.85 | 10.50 |
February | 23.13 | 12.77 |
March | 23.53 | 16.20 |
April | 24.09 | 20.49 |
May | 24.35 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.43 | 28.21 |
September | 24.43 | 26.44 |
October | 24.29 | 20.33 |
November | 24.04 | 17.10 |
December | 23.29 | 12.54 |
Annual Sum or Average | 23.94 | 20.36 |
Minimum of Months | 22.85 | 10.50 |
Maximum of Months | 24.43 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F6 S2 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.84 | 10.50 |
February | 23.13 | 12.77 |
March | 23.53 | 16.20 |
April | 24.09 | 20.49 |
May | 24.35 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.43 | 28.21 |
September | 24.43 | 26.44 |
October | 24.28 | 20.33 |
November | 24.04 | 17.10 |
December | 23.29 | 12.54 |
Annual Sum or Average | 23.94 | 20.36 |
Minimum of Months | 22.84 | 10.50 |
Maximum of Months | 24.43 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F6 CORRIDOR
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.20 | 10.50 |
February | 23.84 | 12.77 |
March | 24.63 | 16.20 |
April | 25.66 | 20.49 |
May | 26.31 | 24.03 |
June | 26.61 | 27.02 |
July | 26.73 | 28.27 |
August | 26.71 | 28.21 |
September | 26.57 | 26.44 |
October | 25.90 | 20.33 |
November | 25.17 | 17.10 |
December | 23.81 | 12.54 |
Annual Sum or Average | 25.44 | 20.36 |
Minimum of Months | 23.20 | 10.50 |
Maximum of Months | 26.73 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F7 SW APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.54 | 10.50 |
February | 22.99 | 12.77 |
March | 23.36 | 16.20 |
April | 24.04 | 20.49 |
May | 24.35 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.22 | 20.33 |
November | 23.87 | 17.10 |
December | 23.04 | 12.54 |
Annual Sum or Average | 23.83 | 20.36 |
Minimum of Months | 22.54 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F7 NW APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.09 | 10.50 |
February | 22.68 | 12.77 |
March | 23.13 | 16.20 |
April | 24.00 | 20.49 |
May | 24.35 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.07 | 20.33 |
November | 23.47 | 17.10 |
December | 22.45 | 12.54 |
Annual Sum or Average | 23.65 | 20.36 |
Minimum of Months | 22.09 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F7 SE APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.45 | 10.50 |
February | 22.91 | 12.77 |
March | 23.31 | 16.20 |
April | 24.02 | 20.49 |
May | 24.36 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.41 | 28.21 |
September | 24.39 | 26.44 |
October | 24.21 | 20.33 |
November | 23.82 | 17.10 |
December | 22.94 | 12.54 |
Annual Sum or Average | 23.80 | 20.36 |
Minimum of Months | 22.45 | 10.50 |
Maximum of Months | 24.41 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F7 NE APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.00 | 10.50 |
February | 22.60 | 12.77 |
March | 23.05 | 16.20 |
April | 23.97 | 20.49 |
May | 24.35 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.06 | 20.33 |
November | 23.42 | 17.10 |
December | 22.35 | 12.54 |
Annual Sum or Average | 23.62 | 20.36 |
Minimum of Months | 22.00 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F7 N1 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.10 | 10.50 |
February | 22.66 | 12.77 |
March | 23.13 | 16.20 |
April | 24.00 | 20.49 |
May | 24.34 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.06 | 20.33 |
November | 23.49 | 17.10 |
December | 22.48 | 12.54 |
Annual Sum or Average | 23.66 | 20.36 |
Minimum of Months | 22.10 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F7 N2 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.10 | 10.50 |
February | 22.66 | 12.77 |
March | 23.12 | 16.20 |
April | 24.00 | 20.49 |
May | 24.34 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.06 | 20.33 |
November | 23.49 | 17.10 |
December | 22.47 | 12.54 |
Annual Sum or Average | 23.65 | 20.36 |
Minimum of Months | 22.10 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F7 S1 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.76 | 10.50 |
February | 23.08 | 12.77 |
March | 23.46 | 16.20 |
April | 24.06 | 20.49 |
May | 24.35 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.43 | 28.21 |
September | 24.43 | 26.44 |
October | 24.27 | 20.33 |
November | 24.00 | 17.10 |
December | 23.23 | 12.54 |
Annual Sum or Average | 23.91 | 20.36 |
Minimum of Months | 22.76 | 10.50 |
Maximum of Months | 24.43 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F7 S2 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.76 | 10.50 |
February | 23.07 | 12.77 |
March | 23.46 | 16.20 |
April | 24.06 | 20.49 |
May | 24.35 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.43 | 28.21 |
September | 24.43 | 26.44 |
October | 24.27 | 20.33 |
November | 24.00 | 17.10 |
December | 23.22 | 12.54 |
Annual Sum or Average | 23.91 | 20.36 |
Minimum of Months | 22.76 | 10.50 |
Maximum of Months | 24.43 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F7 CORRIDOR
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.03 | 10.50 |
February | 23.68 | 12.77 |
March | 24.47 | 16.20 |
April | 25.53 | 20.49 |
May | 26.23 | 24.03 |
June | 26.54 | 27.02 |
July | 26.66 | 28.27 |
August | 26.64 | 28.21 |
September | 26.50 | 26.44 |
October | 25.80 | 20.33 |
November | 25.04 | 17.10 |
December | 23.65 | 12.54 |
Annual Sum or Average | 25.32 | 20.36 |
Minimum of Months | 23.03 | 10.50 |
Maximum of Months | 26.66 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F8 SW APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.48 | 10.50 |
February | 22.95 | 12.77 |
March | 23.30 | 16.20 |
April | 24.01 | 20.49 |
May | 24.35 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.20 | 20.33 |
November | 23.83 | 17.10 |
December | 22.98 | 12.54 |
Annual Sum or Average | 23.81 | 20.36 |
Minimum of Months | 22.48 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F8 NW APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.06 | 10.50 |
February | 22.65 | 12.77 |
March | 23.08 | 16.20 |
April | 23.97 | 20.49 |
May | 24.35 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.05 | 20.33 |
November | 23.44 | 17.10 |
December | 22.41 | 12.54 |
Annual Sum or Average | 23.63 | 20.36 |
Minimum of Months | 22.06 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F8 SE APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.40 | 10.50 |
February | 22.86 | 12.77 |
March | 23.25 | 16.20 |
April | 23.99 | 20.49 |
May | 24.35 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.41 | 28.21 |
September | 24.39 | 26.44 |
October | 24.19 | 20.33 |
November | 23.79 | 17.10 |
December | 22.88 | 12.54 |
Annual Sum or Average | 23.78 | 20.36 |
Minimum of Months | 22.40 | 10.50 |
Maximum of Months | 24.41 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F8 NE APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.98 | 10.50 |
February | 22.57 | 12.77 |
March | 23.01 | 16.20 |
April | 23.94 | 20.49 |
May | 24.35 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.04 | 20.33 |
November | 23.39 | 17.10 |
December | 22.32 | 12.54 |
Annual Sum or Average | 23.60 | 20.36 |
Minimum of Months | 21.98 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F8 N1 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.08 | 10.50 |
February | 22.63 | 12.77 |
March | 23.08 | 16.20 |
April | 23.97 | 20.49 |
May | 24.34 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.04 | 20.33 |
November | 23.46 | 17.10 |
December | 22.44 | 12.54 |
Annual Sum or Average | 23.64 | 20.36 |
Minimum of Months | 22.08 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F8 N2 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.07 | 10.50 |
February | 22.63 | 12.77 |
March | 23.08 | 16.20 |
April | 23.97 | 20.49 |
May | 24.34 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.04 | 20.33 |
November | 23.45 | 17.10 |
December | 22.43 | 12.54 |
Annual Sum or Average | 23.64 | 20.36 |
Minimum of Months | 22.07 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F8 S1 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.69 | 10.50 |
February | 23.03 | 12.77 |
March | 23.40 | 16.20 |
April | 24.03 | 20.49 |
May | 24.35 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.43 | 28.21 |
September | 24.43 | 26.44 |
October | 24.26 | 20.33 |
November | 23.97 | 17.10 |
December | 23.17 | 12.54 |
Annual Sum or Average | 23.88 | 20.36 |
Minimum of Months | 22.69 | 10.50 |
Maximum of Months | 24.43 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F8 S2 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.69 | 10.50 |
February | 23.03 | 12.77 |
March | 23.40 | 16.20 |
April | 24.03 | 20.49 |
May | 24.35 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.43 | 28.21 |
September | 24.43 | 26.44 |
October | 24.25 | 20.33 |
November | 23.97 | 17.10 |
December | 23.16 | 12.54 |
Annual Sum or Average | 23.88 | 20.36 |
Minimum of Months | 22.69 | 10.50 |
Maximum of Months | 24.43 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F8 CORRIDOR
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.94 | 10.50 |
February | 23.60 | 12.77 |
March | 24.40 | 16.20 |
April | 25.49 | 20.49 |
May | 26.23 | 24.03 |
June | 26.55 | 27.02 |
July | 26.67 | 28.27 |
August | 26.65 | 28.21 |
September | 26.50 | 26.44 |
October | 25.76 | 20.33 |
November | 24.98 | 17.10 |
December | 23.57 | 12.54 |
Annual Sum or Average | 25.29 | 20.36 |
Minimum of Months | 22.94 | 10.50 |
Maximum of Months | 26.67 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F9 SW APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.43 | 10.50 |
February | 22.91 | 12.77 |
March | 23.25 | 16.20 |
April | 23.99 | 20.49 |
May | 24.35 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.18 | 20.33 |
November | 23.80 | 17.10 |
December | 22.93 | 12.54 |
Annual Sum or Average | 23.79 | 20.36 |
Minimum of Months | 22.43 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F9 NW APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.04 | 10.50 |
February | 22.63 | 12.77 |
March | 23.05 | 16.20 |
April | 23.95 | 20.49 |
May | 24.34 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.03 | 20.33 |
November | 23.42 | 17.10 |
December | 22.39 | 12.54 |
Annual Sum or Average | 23.62 | 20.36 |
Minimum of Months | 22.04 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F9 SE APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.35 | 10.50 |
February | 22.82 | 12.77 |
March | 23.20 | 16.20 |
April | 23.96 | 20.49 |
May | 24.35 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.41 | 28.21 |
September | 24.39 | 26.44 |
October | 24.17 | 20.33 |
November | 23.75 | 17.10 |
December | 22.82 | 12.54 |
Annual Sum or Average | 23.76 | 20.36 |
Minimum of Months | 22.35 | 10.50 |
Maximum of Months | 24.41 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F9 NE APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.96 | 10.50 |
February | 22.55 | 12.77 |
March | 22.97 | 16.20 |
April | 23.91 | 20.49 |
May | 24.34 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.02 | 20.33 |
November | 23.36 | 17.10 |
December | 22.30 | 12.54 |
Annual Sum or Average | 23.59 | 20.36 |
Minimum of Months | 21.96 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F9 N1 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.06 | 10.50 |
February | 22.62 | 12.77 |
March | 23.05 | 16.20 |
April | 23.95 | 20.49 |
May | 24.34 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.02 | 20.33 |
November | 23.43 | 17.10 |
December | 22.41 | 12.54 |
Annual Sum or Average | 23.63 | 20.36 |
Minimum of Months | 22.06 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F9 N2 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.05 | 10.50 |
February | 22.61 | 12.77 |
March | 23.04 | 16.20 |
April | 23.95 | 20.49 |
May | 24.34 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.38 | 26.44 |
October | 24.02 | 20.33 |
November | 23.42 | 17.10 |
December | 22.40 | 12.54 |
Annual Sum or Average | 23.62 | 20.36 |
Minimum of Months | 22.05 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F9 S1 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.62 | 10.50 |
February | 22.99 | 12.77 |
March | 23.34 | 16.20 |
April | 24.01 | 20.49 |
May | 24.34 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.43 | 28.21 |
September | 24.42 | 26.44 |
October | 24.23 | 20.33 |
November | 23.92 | 17.10 |
December | 23.10 | 12.54 |
Annual Sum or Average | 23.85 | 20.36 |
Minimum of Months | 22.62 | 10.50 |
Maximum of Months | 24.43 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F9 S2 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.62 | 10.50 |
February | 22.98 | 12.77 |
March | 23.34 | 16.20 |
April | 24.00 | 20.49 |
May | 24.34 | 24.03 |
June | 24.40 | 27.02 |
July | 24.40 | 28.27 |
August | 24.43 | 28.21 |
September | 24.42 | 26.44 |
October | 24.23 | 20.33 |
November | 23.92 | 17.10 |
December | 23.09 | 12.54 |
Annual Sum or Average | 23.85 | 20.36 |
Minimum of Months | 22.62 | 10.50 |
Maximum of Months | 24.43 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: F9 CORRIDOR
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.84 | 10.50 |
February | 23.53 | 12.77 |
March | 24.35 | 16.20 |
April | 25.51 | 20.49 |
May | 26.30 | 24.03 |
June | 26.66 | 27.02 |
July | 26.80 | 28.27 |
August | 26.77 | 28.21 |
September | 26.58 | 26.44 |
October | 25.76 | 20.33 |
November | 24.92 | 17.10 |
December | 23.47 | 12.54 |
Annual Sum or Average | 25.30 | 20.36 |
Minimum of Months | 22.84 | 10.50 |
Maximum of Months | 26.80 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.43 | 10.50 |
February | 22.85 | 12.77 |
March | 23.14 | 16.20 |
April | 23.88 | 20.49 |
May | 24.31 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.36 | 26.44 |
October | 24.01 | 20.33 |
November | 23.61 | 17.10 |
December | 22.81 | 12.54 |
Annual Sum or Average | 23.72 | 20.36 |
Minimum of Months | 22.43 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.09 | 10.50 |
February | 22.62 | 12.77 |
March | 23.00 | 16.20 |
April | 23.85 | 20.49 |
May | 24.31 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.36 | 26.44 |
October | 23.88 | 20.33 |
November | 23.32 | 17.10 |
December | 22.42 | 12.54 |
Annual Sum or Average | 23.59 | 20.36 |
Minimum of Months | 22.09 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.36 | 10.50 |
February | 22.77 | 12.77 |
March | 23.10 | 16.20 |
April | 23.85 | 20.49 |
May | 24.31 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.41 | 28.21 |
September | 24.37 | 26.44 |
October | 23.99 | 20.33 |
November | 23.56 | 17.10 |
December | 22.73 | 12.54 |
Annual Sum or Average | 23.69 | 20.36 |
Minimum of Months | 22.36 | 10.50 |
Maximum of Months | 24.41 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.99 | 10.50 |
February | 22.53 | 12.77 |
March | 22.94 | 16.20 |
April | 23.81 | 20.49 |
May | 24.30 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.36 | 26.44 |
October | 23.86 | 20.33 |
November | 23.27 | 17.10 |
December | 22.32 | 12.54 |
Annual Sum or Average | 23.55 | 20.36 |
Minimum of Months | 21.99 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.08 | 10.50 |
February | 22.60 | 12.77 |
March | 22.99 | 16.20 |
April | 23.85 | 20.49 |
May | 24.30 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.36 | 26.44 |
October | 23.87 | 20.33 |
November | 23.31 | 17.10 |
December | 22.39 | 12.54 |
Annual Sum or Average | 23.58 | 20.36 |
Minimum of Months | 22.08 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.07 | 10.50 |
February | 22.59 | 12.77 |
March | 22.99 | 16.20 |
April | 23.85 | 20.49 |
May | 24.30 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.40 | 28.21 |
September | 24.36 | 26.44 |
October | 23.87 | 20.33 |
November | 23.31 | 17.10 |
December | 22.38 | 12.54 |
Annual Sum or Average | 23.58 | 20.36 |
Minimum of Months | 22.07 | 10.50 |
Maximum of Months | 24.40 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.57 | 10.50 |
February | 22.93 | 12.77 |
March | 23.21 | 16.20 |
April | 23.91 | 20.49 |
May | 24.31 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.41 | 28.21 |
September | 24.37 | 26.44 |
October | 24.05 | 20.33 |
November | 23.71 | 17.10 |
December | 22.93 | 12.54 |
Annual Sum or Average | 23.77 | 20.36 |
Minimum of Months | 22.57 | 10.50 |
Maximum of Months | 24.41 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.57 | 10.50 |
February | 22.93 | 12.77 |
March | 23.21 | 16.20 |
April | 23.91 | 20.49 |
May | 24.31 | 24.03 |
June | 24.39 | 27.02 |
July | 24.40 | 28.27 |
August | 24.41 | 28.21 |
September | 24.37 | 26.44 |
October | 24.05 | 20.33 |
November | 23.70 | 17.10 |
December | 22.93 | 12.54 |
Annual Sum or Average | 23.77 | 20.36 |
Minimum of Months | 22.57 | 10.50 |
Maximum of Months | 24.41 | 28.27 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2015-09-09 19:11:57
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.11 | 10.50 |
February | 23.89 | 12.77 |
March | 24.81 | 16.20 |
April | 26.16 | 20.49 |
May | 27.10 | 24.03 |
June | 27.60 | 27.02 |
July | 27.78 | 28.27 |
August | 27.74 | 28.21 |
September | 27.41 | 26.44 |
October | 26.29 | 20.33 |
November | 25.30 | 17.10 |
December | 23.75 | 12.54 |
Annual Sum or Average | 25.92 | 20.36 |
Minimum of Months | 23.11 | 10.50 |
Maximum of Months | 27.78 | 28.27 |
Report: COMPONENTS OF PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2015-09-09 19:11:57
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W] | |
January | 0.223190E+12 | 130650.694 | 18-JAN-20:00 | 14401.373 | 49889.926 | 20924.025 | 30976.465 | 0.000 | 10364.000 | 2453.601 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
February | 0.205752E+12 | 140372.331 | 28-FEB-17:15 | 11327.174 | 57142.088 | 20924.025 | 0.000 | 44388.762 | 0.000 | 2453.601 | 2141.485 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
March | 0.228462E+12 | 165742.896 | 26-MAR-16:15 | 11327.174 | 57042.023 | 20924.025 | 0.000 | 69041.782 | 0.000 | 2453.601 | 2966.649 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
April | 0.253760E+12 | 179535.504 | 30-APR-18:00 | 14401.373 | 51749.961 | 20924.025 | 0.000 | 74427.154 | 10364.000 | 2453.601 | 3454.365 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
May | 0.312297E+12 | 177655.633 | 23-MAY-17:30 | 13120.457 | 57042.023 | 20924.025 | 0.000 | 78637.183 | 0.000 | 2453.601 | 3490.335 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
June | 0.347134E+12 | 184680.531 | 25-JUN-17:15 | 13120.457 | 57042.023 | 20924.025 | 0.000 | 85499.424 | 0.000 | 2453.601 | 3653.190 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
July | 0.371650E+12 | 187111.801 | 12-JUL-17:15 | 13120.457 | 57042.023 | 20924.025 | 0.000 | 87930.694 | 0.000 | 2453.601 | 3653.190 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.370077E+12 | 189408.373 | 04-AUG-17:15 | 13120.457 | 57042.023 | 20924.025 | 0.000 | 90227.266 | 0.000 | 2453.601 | 3653.190 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.338641E+12 | 182155.607 | 20-SEP-16:15 | 11327.174 | 57142.088 | 20924.025 | 0.000 | 84660.333 | 0.000 | 2453.601 | 3653.190 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
October | 0.273095E+12 | 179614.886 | 01-OCT-16:15 | 11327.174 | 57042.023 | 20924.025 | 0.000 | 82227.231 | 0.000 | 2453.601 | 3653.190 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
November | 0.239189E+12 | 175635.483 | 27-NOV-17:30 | 11327.174 | 57142.088 | 20924.025 | 0.000 | 68168.264 | 10364.000 | 2453.601 | 3261.173 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
December | 0.223531E+12 | 144008.962 | 08-DEC-17:30 | 11327.174 | 57142.088 | 20924.025 | 0.000 | 37753.934 | 10364.000 | 2453.601 | 2048.982 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.338678E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||||
Minimum of Months | 0.205752E+12 | 130650.694 | 11327.174 | 49889.926 | 20924.025 | 0.000 | 0.000 | 0.000 | 2453.601 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.371650E+12 | 189408.373 | 14401.373 | 57142.088 | 20924.025 | 30976.465 | 90227.266 | 10364.000 | 2453.601 | 3653.190 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: COMPONENTS OF PEAK GAS DEMAND
For: Meter
Timestamp: 2015-09-09 19:11:57
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC [Invalid/Undefined] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT {AT MAX/MIN} [W] | WATERSYSTEMS:GAS {AT MAX/MIN} [W] | WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.143249E+12 | 208344.740 | 22-JAN-07:15 | 0.000 | 0.000 | 0.000 | 208344.740 | 73953.590 | 73953.590 | 134391.150 |
February | 0.124621E+12 | 278005.552 | 11-FEB-06:45 | 0.000 | 0.000 | 0.000 | 278005.552 | 72689.019 | 72689.019 | 205316.533 |
March | 0.974440E+11 | 158569.136 | 19-MAR-05:30 | 0.000 | 0.000 | 0.000 | 158569.136 | 70205.474 | 70205.474 | 88363.662 |
April | 0.777382E+11 | 72747.416 | 01-APR-06:00 | 0.000 | 0.000 | 0.000 | 72747.416 | 72747.416 | 72747.416 | 0.000 |
May | 0.743155E+11 | 70981.441 | 01-MAY-06:45 | 0.000 | 0.000 | 0.000 | 70981.441 | 70981.441 | 70981.441 | 0.000 |
June | 0.670852E+11 | 69265.839 | 02-JUN-06:45 | 0.000 | 0.000 | 0.000 | 69265.839 | 69265.839 | 69265.839 | 0.000 |
July | 0.666606E+11 | 68132.615 | 06-JUL-06:45 | 0.000 | 0.000 | 0.000 | 68132.615 | 68132.615 | 68132.615 | 0.000 |
August | 0.670914E+11 | 68343.992 | 30-AUG-06:30 | 0.000 | 0.000 | 0.000 | 68343.992 | 68343.992 | 68343.992 | 0.000 |
September | 0.681951E+11 | 69593.401 | 28-SEP-06:45 | 0.000 | 0.000 | 0.000 | 69593.401 | 69593.401 | 69593.401 | 0.000 |
October | 0.758837E+11 | 71329.204 | 29-OCT-06:45 | 0.000 | 0.000 | 0.000 | 71329.204 | 71329.204 | 71329.204 | 0.000 |
November | 0.820737E+11 | 126452.359 | 10-NOV-06:30 | 0.000 | 0.000 | 0.000 | 126452.359 | 69115.940 | 69115.940 | 57336.419 |
December | 0.115028E+12 | 178471.250 | 21-DEC-06:45 | 0.000 | 0.000 | 0.000 | 178471.250 | 72180.690 | 72180.690 | 106290.560 |
Annual Sum or Average | 0.105939E+13 | 0.000 | 0.000 | 0.000 | ||||||
Minimum of Months | 0.666606E+11 | 68132.615 | 0.000 | 0.000 | 0.000 | 68132.615 | 68132.615 | 68132.615 | 0.000 | |
Maximum of Months | 0.143249E+12 | 278005.552 | 0.000 | 0.000 | 0.000 | 278005.552 | 73953.590 | 73953.590 | 205316.533 |