Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:59

Tabular Output Report in Format: HTML

Building: High-Rise Apartment

Environment: El Paso International Ap Ut TX USA TMY3 WMO#=722700

Simulation Timestamp: 2015-09-09 19:00:30


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 4112.35 524.77 582.49
Net Site Energy 4112.35 524.77 582.49
Total Source Energy 10864.79 1386.44 1538.95
Net Source Energy 10864.79 1386.44 1538.95


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 7836.48
Net Conditioned Building Area 7059.89
Unconditioned Building Area 776.58


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 30.37 61.66 0.00 0.00 0.00 0.00
Cooling 636.60 0.00 0.00 0.00 0.00 0.00
Interior Lighting 296.56 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 162.97 0.00 0.00 0.00 0.00 0.00
Interior Equipment 1137.32 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 695.01 0.00 0.00 0.00 0.00 0.00
Pumps 56.84 0.00 0.00 0.00 0.00 0.00
Heat Rejection 24.02 0.00 0.00 0.00 0.00 2186.76
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 974.83 0.00 0.00 0.00 4778.51
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 3075.86 1036.49 0.00 0.00 0.00 6965.27
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating Boiler 0.00 61.66 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
  Other 30.37 0.00 0.00 0.00 0.00 0.00
Cooling General 636.60 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 242.55 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 54.01 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 162.97 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 1137.32 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 695.01 0.00 0.00 0.00 0.00 0.00
Pumps General 56.84 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 24.02 0.00 0.00 0.00 0.00 2186.76
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 974.83 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 4778.51
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 65.09 0.00 0.00 0.00 0.00 0.00
HVAC 204.37 146.81 0.00 0.00 0.00 0.99
Other 161.10 0.00 0.00 0.00 0.00 0.00
Total 435.68 146.81 0.00 0.00 0.00 0.99


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 58.64 0.00 0.00 0.00 0.00 0.00
HVAC 184.12 132.26 0.00 0.00 0.00 0.89
Other 145.13 0.00 0.00 0.00 0.00 0.00
Total 392.50 132.26 0.00 0.00 0.00 0.89


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 3075.86 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 3075.86 100.00
     
Total On-Site and Utility Electric Sources 3075.86 100.00
Total Electricity End Uses 3075.86 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 6965.27 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 6965.27 100.00
Total Water End Uses 6965.27 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 65.00
Time Setpoint Not Met During Occupied Cooling 245.00
Time Not Comfortable Based on Simple ASHRAE 55-2004 1242.25


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |

COMPONENTS OF PEAK ELECTRICAL DEMAND

| Meter |

COMPONENTS OF PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:59
RunPeriod El Paso International Ap Ut TX USA TMY3 WMO#=722700
Weather File El Paso International Ap Ut TX USA TMY3 WMO#=722700
Latitude [deg] 31.77
Longitude [deg] -106.5
Elevation [m] 1186.00
Time Zone -7.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3855.02 1411.96 515.55 1411.96 515.55
Window Opening Area [m2] 1150.39 423.59 152.73 423.59 150.48
Window-Wall Ratio [%] 29.84 30.00 29.62 30.00 29.19


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3752.84 1411.96 464.46 1411.96 464.46
Window Opening Area [m2] 1125.85 423.59 139.34 423.59 139.34
Window-Wall Ratio [%] 30.00 30.00 30.00 30.00 30.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
OFFICE 88.25 Yes Yes 268.96 1.00 58.52 17.56 29.5362 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 4.47 6.7128   0.0000
F2 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F3 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F4 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
M SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
M CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 13.4255   0.0000
F6 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F7 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F8 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F9 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
T SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   264.3872
Total 7836.48     23884.04   3855.02 1150.39 4.3335 39.48 8.6291
Conditioned Total 7059.89     21517.16   3752.84 1125.85 3.9979 35.57 6.6700
Unconditioned Total 776.58     2366.87   102.18 24.54 7.3840   26.4387
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 17-JUL-19:00 27-DEC-07:30 - - - 14-JUN-17:15
Heating 0.00 82687.13 0.00 0.00 0.00 0.00
Cooling 63390.96 0.00 0.00 0.00 0.00 0.00
Interior Lighting 14401.37 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 10364.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 49889.93 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 22038.65 0.00 0.00 0.00 0.00 0.00
Pumps 1833.52 0.00 0.00 0.00 0.00 0.00
Heat Rejection 2346.06 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 76170.72 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 165905.79 158857.86 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating Boiler 0.00 82687.13 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 63390.96 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 11484.27 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 2917.11 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 10364.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 49889.93 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 22038.65 0.00 0.00 0.00 0.00 0.00
Pumps General 1833.52 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 2346.06 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 76170.72 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 96.17 66.84 0.00 0.00 0.00
Cooling 2016.10 0.00 0.00 0.00 0.00
Interior Lighting 939.20 0.00 0.00 0.00 0.00
Exterior Lighting 516.13 0.00 0.00 0.00 0.00
Interior Equipment 3601.91 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 2201.10 0.00 0.00 0.00 0.00
Pumps 180.00 0.00 0.00 0.00 0.00
Heat Rejection 76.06 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 1056.72 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 9741.24 1123.55 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 13.62 9.47 0.00 0.00 0.00
Cooling 285.57 0.00 0.00 0.00 0.00
Interior Lighting 133.03 0.00 0.00 0.00 0.00
Exterior Lighting 73.11 0.00 0.00 0.00 0.00
Interior Equipment 510.19 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 311.78 0.00 0.00 0.00 0.00
Pumps 25.50 0.00 0.00 0.00 0.00
Heat Rejection 10.77 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 149.68 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1379.80 159.15 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 13.62 9.47 0.00 0.00 0.00
Cooling 285.57 0.00 0.00 0.00 0.00
Interior Lighting 133.03 0.00 0.00 0.00 0.00
Exterior Lighting 73.11 0.00 0.00 0.00 0.00
Interior Equipment 510.19 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 311.78 0.00 0.00 0.00 0.00
Pumps 25.50 0.00 0.00 0.00 0.00
Heat Rejection 10.77 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 149.68 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1379.80 159.15 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB -5.20 0.00 -5.20 Wetbulb [C] 2.20 20.00
EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 38.10 13.00 18.10 Wetbulb [C] 3.90 280.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 270.00 180.00  
F2 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F2 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F2 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F2 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F2 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F2 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F3 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F3 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F3 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F3 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F3 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F3 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F4 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F4 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F4 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F4 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F4 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F4 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
M WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F6 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F6 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F6 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F6 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F6 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F6 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F7 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F7 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F7 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F7 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F7 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F7 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F8 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F8 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F8 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F8 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F8 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F8 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F9 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F9 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F9 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F9 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F9 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F9 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.30 0.269 0.283 77.66 0.00 0.00  


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW3 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No G SWALL SWA 180.00 90.00 S
GWINDOW2 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No G WWALL SWA 270.00 90.00 W
GWINDOW4 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No G NWALL NWA 0.00 90.00 N
GWINDOW6 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No G WWALL NWA 270.00 90.00 W
GWINDOW1 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No G SWALL SEA 180.00 90.00 S
GWINDOW8 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No G EWALL SEA 90.00 90.00 E
GWINDOW5 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No G NWALL NEA 0.00 90.00 N
GWINDOW7 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No G EWALL NEA 90.00 90.00 E
GWINDOW9 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No G NWALL N1A 0.00 90.00 N
GWINDOW10 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No G NWALL N2A 0.00 90.00 N
GWINDOW11 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No G SWALL S1A 180.00 90.00 S
GWINDOW12 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No G SWALL S2A 180.00 90.00 S
GWINDOW13 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No G WWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.65_SHGC_0.25 3.36 0.00 0.00 3.36 3.36 2.848 0.287 0.200     No G EWALL C 90.00 90.00 E
F2WINDOW2 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F2 WWALL SWA 270.00 90.00 W
F2WINDOW3 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F2 SWALL SWA 180.00 90.00 S
F2WINDOW4 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F2 NWALL NWA 0.00 90.00 N
F2WINDOW6 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F2 WWALL NWA 270.00 90.00 W
F2WINDOW8 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F2 EWALL SEA 90.00 90.00 E
F2WINDOW1 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F2 SWALL SEA 180.00 90.00 S
F2WINDOW5 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F2 NWALL NEA 0.00 90.00 N
F2WINDOW7 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F2 EWALL NEA 90.00 90.00 E
F2WINDOW9 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F2 NWALL N1A 0.00 90.00 N
F2WINDOW10 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F2 NWALL N2A 0.00 90.00 N
F2WINDOW11 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F2 SWALL S1A 180.00 90.00 S
F2WINDOW12 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F2 SWALL S2A 180.00 90.00 S
F2WINDOW13 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F2 WWALL C 270.00 90.00 W
F2WINDOW14 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F2 EWALL C 90.00 90.00 E
F3WINDOW2 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F3 WWALL SWA 270.00 90.00 W
F3WINDOW3 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F3 SWALL SWA 180.00 90.00 S
F3WINDOW4 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F3 NWALL NWA 0.00 90.00 N
F3WINDOW6 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F3 WWALL NWA 270.00 90.00 W
F3WINDOW8 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F3 EWALL SEA 90.00 90.00 E
F3WINDOW1 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F3 SWALL SEA 180.00 90.00 S
F3WINDOW5 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F3 NWALL NEA 0.00 90.00 N
F3WINDOW7 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F3 EWALL NEA 90.00 90.00 E
F3WINDOW9 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F3 NWALL N1A 0.00 90.00 N
F3WINDOW10 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F3 NWALL N2A 0.00 90.00 N
F3WINDOW11 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F3 SWALL S1A 180.00 90.00 S
F3WINDOW12 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F3 SWALL S2A 180.00 90.00 S
F3WINDOW13 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F3 WWALL C 270.00 90.00 W
F3WINDOW14 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F3 EWALL C 90.00 90.00 E
F4WINDOW2 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F4 WWALL SWA 270.00 90.00 W
F4WINDOW3 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F4 SWALL SWA 180.00 90.00 S
F4WINDOW4 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F4 NWALL NWA 0.00 90.00 N
F4WINDOW6 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F4 WWALL NWA 270.00 90.00 W
F4WINDOW8 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F4 EWALL SEA 90.00 90.00 E
F4WINDOW1 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F4 SWALL SEA 180.00 90.00 S
F4WINDOW5 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F4 NWALL NEA 0.00 90.00 N
F4WINDOW7 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F4 EWALL NEA 90.00 90.00 E
F4WINDOW9 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F4 NWALL N1A 0.00 90.00 N
F4WINDOW10 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F4 NWALL N2A 0.00 90.00 N
F4WINDOW11 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F4 SWALL S1A 180.00 90.00 S
F4WINDOW12 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F4 SWALL S2A 180.00 90.00 S
F4WINDOW13 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F4 WWALL C 270.00 90.00 W
F4WINDOW14 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F4 EWALL C 90.00 90.00 E
MWINDOW2 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No M WWALL SWA 270.00 90.00 W
MWINDOW3 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No M SWALL SWA 180.00 90.00 S
MWINDOW4 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No M NWALL NWA 0.00 90.00 N
MWINDOW6 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No M WWALL NWA 270.00 90.00 W
MWINDOW8 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No M EWALL SEA 90.00 90.00 E
MWINDOW1 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No M SWALL SEA 180.00 90.00 S
MWINDOW5 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No M NWALL NEA 0.00 90.00 N
MWINDOW7 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No M EWALL NEA 90.00 90.00 E
MWINDOW9 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No M NWALL N1A 0.00 90.00 N
MWINDOW10 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No M NWALL N2A 0.00 90.00 N
MWINDOW11 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No M SWALL S1A 180.00 90.00 S
MWINDOW12 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No M SWALL S2A 180.00 90.00 S
MWINDOW13 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No M WWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No M EWALL C 90.00 90.00 E
F6WINDOW2 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F6 WWALL SWA 270.00 90.00 W
F6WINDOW3 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F6 SWALL SWA 180.00 90.00 S
F6WINDOW4 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F6 NWALL NWA 0.00 90.00 N
F6WINDOW6 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F6 WWALL NWA 270.00 90.00 W
F6WINDOW8 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F6 EWALL SEA 90.00 90.00 E
F6WINDOW1 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F6 SWALL SEA 180.00 90.00 S
F6WINDOW5 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F6 NWALL NEA 0.00 90.00 N
F6WINDOW7 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F6 EWALL NEA 90.00 90.00 E
F6WINDOW9 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F6 NWALL N1A 0.00 90.00 N
F6WINDOW10 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F6 NWALL N2A 0.00 90.00 N
F6WINDOW11 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F6 SWALL S1A 180.00 90.00 S
F6WINDOW12 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F6 SWALL S2A 180.00 90.00 S
F6WINDOW13 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F6 WWALL C 270.00 90.00 W
F6WINDOW14 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F6 EWALL C 90.00 90.00 E
F7WINDOW2 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F7 WWALL SWA 270.00 90.00 W
F7WINDOW3 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F7 SWALL SWA 180.00 90.00 S
F7WINDOW4 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F7 NWALL NWA 0.00 90.00 N
F7WINDOW6 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F7 WWALL NWA 270.00 90.00 W
F7WINDOW8 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F7 EWALL SEA 90.00 90.00 E
F7WINDOW1 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F7 SWALL SEA 180.00 90.00 S
F7WINDOW5 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F7 NWALL NEA 0.00 90.00 N
F7WINDOW7 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F7 EWALL NEA 90.00 90.00 E
F7WINDOW9 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F7 NWALL N1A 0.00 90.00 N
F7WINDOW10 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F7 NWALL N2A 0.00 90.00 N
F7WINDOW11 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F7 SWALL S1A 180.00 90.00 S
F7WINDOW12 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F7 SWALL S2A 180.00 90.00 S
F7WINDOW13 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F7 WWALL C 270.00 90.00 W
F7WINDOW14 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F7 EWALL C 90.00 90.00 E
F8WINDOW2 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F8 WWALL SWA 270.00 90.00 W
F8WINDOW3 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F8 SWALL SWA 180.00 90.00 S
F8WINDOW4 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F8 NWALL NWA 0.00 90.00 N
F8WINDOW6 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F8 WWALL NWA 270.00 90.00 W
F8WINDOW8 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F8 EWALL SEA 90.00 90.00 E
F8WINDOW1 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F8 SWALL SEA 180.00 90.00 S
F8WINDOW5 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F8 NWALL NEA 0.00 90.00 N
F8WINDOW7 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F8 EWALL NEA 90.00 90.00 E
F8WINDOW9 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F8 NWALL N1A 0.00 90.00 N
F8WINDOW10 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F8 NWALL N2A 0.00 90.00 N
F8WINDOW11 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F8 SWALL S1A 180.00 90.00 S
F8WINDOW12 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F8 SWALL S2A 180.00 90.00 S
F8WINDOW13 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F8 WWALL C 270.00 90.00 W
F8WINDOW14 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F8 EWALL C 90.00 90.00 E
F9WINDOW2 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F9 WWALL SWA 270.00 90.00 W
F9WINDOW3 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F9 SWALL SWA 180.00 90.00 S
F9WINDOW4 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F9 NWALL NWA 0.00 90.00 N
F9WINDOW6 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F9 WWALL NWA 270.00 90.00 W
F9WINDOW8 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F9 EWALL SEA 90.00 90.00 E
F9WINDOW1 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F9 SWALL SEA 180.00 90.00 S
F9WINDOW5 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F9 NWALL NEA 0.00 90.00 N
F9WINDOW7 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No F9 EWALL NEA 90.00 90.00 E
F9WINDOW9 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F9 NWALL N1A 0.00 90.00 N
F9WINDOW10 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F9 NWALL N2A 0.00 90.00 N
F9WINDOW11 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F9 SWALL S1A 180.00 90.00 S
F9WINDOW12 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No F9 SWALL S2A 180.00 90.00 S
F9WINDOW13 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F9 WWALL C 270.00 90.00 W
F9WINDOW14 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No F9 EWALL C 90.00 90.00 E
TWINDOW2 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No T WWALL SWA 270.00 90.00 W
TWINDOW3 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No T SWALL SWA 180.00 90.00 S
TWINDOW4 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No T NWALL NWA 0.00 90.00 N
TWINDOW6 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No T WWALL NWA 270.00 90.00 W
TWINDOW8 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No T EWALL SEA 90.00 90.00 E
TWINDOW1 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No T SWALL SEA 180.00 90.00 S
TWINDOW5 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No T NWALL NEA 0.00 90.00 N
TWINDOW7 WINDOW_U_0.65_SHGC_0.25 6.97 0.00 0.00 6.97 6.97 2.848 0.287 0.200     No T EWALL NEA 90.00 90.00 E
TWINDOW9 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No T NWALL N1A 0.00 90.00 N
TWINDOW10 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No T NWALL N2A 0.00 90.00 N
TWINDOW11 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No T SWALL S1A 180.00 90.00 S
TWINDOW12 WINDOW_U_0.65_SHGC_0.25 10.59 0.00 0.00 10.59 10.59 2.848 0.287 0.200     No T SWALL S2A 180.00 90.00 S
TWINDOW13 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No T WWALL C 270.00 90.00 W
TWINDOW14 WINDOW_U_0.65_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No T EWALL C 90.00 90.00 E
Total or Average           1150.39 2.848 0.287 0.200              
North Total or Average           423.59 2.848 0.287 0.200              
Non-North Total or Average           726.80 2.848 0.287 0.200              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
GWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
GWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
GWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
GWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F2WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F2WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F2WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F2WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F2WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F2WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F3WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F3WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F3WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F3WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F3WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F3WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F4WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F4WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F4WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F4WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F4WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F4WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
MWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
MWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
MWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
MWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
MWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F6WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F6WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F6WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F6WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F6WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F6WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F7WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F7WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F7WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F7WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F7WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F7WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F8WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F8WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F8WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F8WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F8WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F8WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F9WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F9WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F9WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F9WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
F9WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
F9WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
TWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
TWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
TWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
TWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00
TWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 0.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
G SW APARTMENT_LIGHTS_HARDWIRED G SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G NW APARTMENT_LIGHTS_HARDWIRED G NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
OFFICE_LIGHTS_HARDWIRED OFFICE 14.7681 88.25 1303.26 GeneralLights LTG_OFF_SCH 62.05 168.00 61.07 0.0000 Y 14.94
G NE APARTMENT_LIGHTS_HARDWIRED G NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G N1 APARTMENT_LIGHTS_HARDWIRED G N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G N2 APARTMENT_LIGHTS_HARDWIRED G N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G S1 APARTMENT_LIGHTS_HARDWIRED G S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G S2 APARTMENT_LIGHTS_HARDWIRED G S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G CORRIDOR_LIGHTS_HARDWIRED G CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F2 SW APARTMENT_LIGHTS_HARDWIRED F2 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 NW APARTMENT_LIGHTS_HARDWIRED F2 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 SE APARTMENT_LIGHTS_HARDWIRED F2 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 NE APARTMENT_LIGHTS_HARDWIRED F2 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 N1 APARTMENT_LIGHTS_HARDWIRED F2 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 N2 APARTMENT_LIGHTS_HARDWIRED F2 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 S1 APARTMENT_LIGHTS_HARDWIRED F2 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 S2 APARTMENT_LIGHTS_HARDWIRED F2 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 CORRIDOR_LIGHTS_HARDWIRED F2 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F3 SW APARTMENT_LIGHTS_HARDWIRED F3 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 NW APARTMENT_LIGHTS_HARDWIRED F3 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 SE APARTMENT_LIGHTS_HARDWIRED F3 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 NE APARTMENT_LIGHTS_HARDWIRED F3 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 N1 APARTMENT_LIGHTS_HARDWIRED F3 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 N2 APARTMENT_LIGHTS_HARDWIRED F3 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 S1 APARTMENT_LIGHTS_HARDWIRED F3 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 S2 APARTMENT_LIGHTS_HARDWIRED F3 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 CORRIDOR_LIGHTS_HARDWIRED F3 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F4 SW APARTMENT_LIGHTS_HARDWIRED F4 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 NW APARTMENT_LIGHTS_HARDWIRED F4 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 SE APARTMENT_LIGHTS_HARDWIRED F4 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 NE APARTMENT_LIGHTS_HARDWIRED F4 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 N1 APARTMENT_LIGHTS_HARDWIRED F4 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 N2 APARTMENT_LIGHTS_HARDWIRED F4 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 S1 APARTMENT_LIGHTS_HARDWIRED F4 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 S2 APARTMENT_LIGHTS_HARDWIRED F4 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 CORRIDOR_LIGHTS_HARDWIRED F4 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
M SW APARTMENT_LIGHTS_HARDWIRED M SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M NW APARTMENT_LIGHTS_HARDWIRED M NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M SE APARTMENT_LIGHTS_HARDWIRED M SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M NE APARTMENT_LIGHTS_HARDWIRED M NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M N1 APARTMENT_LIGHTS_HARDWIRED M N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M N2 APARTMENT_LIGHTS_HARDWIRED M N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M S1 APARTMENT_LIGHTS_HARDWIRED M S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M S2 APARTMENT_LIGHTS_HARDWIRED M S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M CORRIDOR_LIGHTS_HARDWIRED M CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F6 SW APARTMENT_LIGHTS_HARDWIRED F6 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 NW APARTMENT_LIGHTS_HARDWIRED F6 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 SE APARTMENT_LIGHTS_HARDWIRED F6 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 NE APARTMENT_LIGHTS_HARDWIRED F6 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 N1 APARTMENT_LIGHTS_HARDWIRED F6 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 N2 APARTMENT_LIGHTS_HARDWIRED F6 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 S1 APARTMENT_LIGHTS_HARDWIRED F6 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 S2 APARTMENT_LIGHTS_HARDWIRED F6 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 CORRIDOR_LIGHTS_HARDWIRED F6 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F7 SW APARTMENT_LIGHTS_HARDWIRED F7 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 NW APARTMENT_LIGHTS_HARDWIRED F7 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 SE APARTMENT_LIGHTS_HARDWIRED F7 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 NE APARTMENT_LIGHTS_HARDWIRED F7 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 N1 APARTMENT_LIGHTS_HARDWIRED F7 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 N2 APARTMENT_LIGHTS_HARDWIRED F7 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 S1 APARTMENT_LIGHTS_HARDWIRED F7 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 S2 APARTMENT_LIGHTS_HARDWIRED F7 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 CORRIDOR_LIGHTS_HARDWIRED F7 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F8 SW APARTMENT_LIGHTS_HARDWIRED F8 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 NW APARTMENT_LIGHTS_HARDWIRED F8 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 SE APARTMENT_LIGHTS_HARDWIRED F8 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 NE APARTMENT_LIGHTS_HARDWIRED F8 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 N1 APARTMENT_LIGHTS_HARDWIRED F8 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 N2 APARTMENT_LIGHTS_HARDWIRED F8 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 S1 APARTMENT_LIGHTS_HARDWIRED F8 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 S2 APARTMENT_LIGHTS_HARDWIRED F8 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 CORRIDOR_LIGHTS_HARDWIRED F8 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F9 SW APARTMENT_LIGHTS_HARDWIRED F9 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 NW APARTMENT_LIGHTS_HARDWIRED F9 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 SE APARTMENT_LIGHTS_HARDWIRED F9 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 NE APARTMENT_LIGHTS_HARDWIRED F9 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 N1 APARTMENT_LIGHTS_HARDWIRED F9 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 N2 APARTMENT_LIGHTS_HARDWIRED F9 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 S1 APARTMENT_LIGHTS_HARDWIRED F9 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 S2 APARTMENT_LIGHTS_HARDWIRED F9 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 CORRIDOR_LIGHTS_HARDWIRED F9 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
T SW APARTMENT_LIGHTS_HARDWIRED T SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T NW APARTMENT_LIGHTS_HARDWIRED T NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T SE APARTMENT_LIGHTS_HARDWIRED T SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T NE APARTMENT_LIGHTS_HARDWIRED T NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T N1 APARTMENT_LIGHTS_HARDWIRED T N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T N2 APARTMENT_LIGHTS_HARDWIRED T N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T S1 APARTMENT_LIGHTS_HARDWIRED T S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T S2 APARTMENT_LIGHTS_HARDWIRED T S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T CORRIDOR_LIGHTS_HARDWIRED T CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
G SW APARTMENT_LIGHTS_PLUGIN G SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G NW APARTMENT_LIGHTS_PLUGIN G NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
OFFICE_LIGHTS_PLUGIN OFFICE 14.7681 88.25 1303.26 GeneralLights-plugin LTG_OFF_SCH 62.05 168.00 61.07 0.0000 Y 14.94
G NE APARTMENT_LIGHTS_PLUGIN G NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G N1 APARTMENT_LIGHTS_PLUGIN G N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G N2 APARTMENT_LIGHTS_PLUGIN G N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G S1 APARTMENT_LIGHTS_PLUGIN G S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G S2 APARTMENT_LIGHTS_PLUGIN G S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 SW APARTMENT_LIGHTS_PLUGIN F2 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 NW APARTMENT_LIGHTS_PLUGIN F2 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 SE APARTMENT_LIGHTS_PLUGIN F2 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 NE APARTMENT_LIGHTS_PLUGIN F2 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 N1 APARTMENT_LIGHTS_PLUGIN F2 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 N2 APARTMENT_LIGHTS_PLUGIN F2 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 S1 APARTMENT_LIGHTS_PLUGIN F2 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 S2 APARTMENT_LIGHTS_PLUGIN F2 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 SW APARTMENT_LIGHTS_PLUGIN F3 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 NW APARTMENT_LIGHTS_PLUGIN F3 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 SE APARTMENT_LIGHTS_PLUGIN F3 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 NE APARTMENT_LIGHTS_PLUGIN F3 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 N1 APARTMENT_LIGHTS_PLUGIN F3 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 N2 APARTMENT_LIGHTS_PLUGIN F3 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 S1 APARTMENT_LIGHTS_PLUGIN F3 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 S2 APARTMENT_LIGHTS_PLUGIN F3 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 SW APARTMENT_LIGHTS_PLUGIN F4 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 NW APARTMENT_LIGHTS_PLUGIN F4 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 SE APARTMENT_LIGHTS_PLUGIN F4 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 NE APARTMENT_LIGHTS_PLUGIN F4 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 N1 APARTMENT_LIGHTS_PLUGIN F4 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 N2 APARTMENT_LIGHTS_PLUGIN F4 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 S1 APARTMENT_LIGHTS_PLUGIN F4 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 S2 APARTMENT_LIGHTS_PLUGIN F4 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M SW APARTMENT_LIGHTS_PLUGIN M SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M NW APARTMENT_LIGHTS_PLUGIN M NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M SE APARTMENT_LIGHTS_PLUGIN M SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M NE APARTMENT_LIGHTS_PLUGIN M NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M N1 APARTMENT_LIGHTS_PLUGIN M N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M N2 APARTMENT_LIGHTS_PLUGIN M N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M S1 APARTMENT_LIGHTS_PLUGIN M S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M S2 APARTMENT_LIGHTS_PLUGIN M S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M CORRIDOR_LIGHTS_PLUGIN M CORRIDOR 6.7128 77.66 521.30 GeneralLights-plugin LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F6 SW APARTMENT_LIGHTS_PLUGIN F6 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 NW APARTMENT_LIGHTS_PLUGIN F6 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 SE APARTMENT_LIGHTS_PLUGIN F6 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 NE APARTMENT_LIGHTS_PLUGIN F6 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 N1 APARTMENT_LIGHTS_PLUGIN F6 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 N2 APARTMENT_LIGHTS_PLUGIN F6 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 S1 APARTMENT_LIGHTS_PLUGIN F6 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 S2 APARTMENT_LIGHTS_PLUGIN F6 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 SW APARTMENT_LIGHTS_PLUGIN F7 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 NW APARTMENT_LIGHTS_PLUGIN F7 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 SE APARTMENT_LIGHTS_PLUGIN F7 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 NE APARTMENT_LIGHTS_PLUGIN F7 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 N1 APARTMENT_LIGHTS_PLUGIN F7 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 N2 APARTMENT_LIGHTS_PLUGIN F7 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 S1 APARTMENT_LIGHTS_PLUGIN F7 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 S2 APARTMENT_LIGHTS_PLUGIN F7 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 SW APARTMENT_LIGHTS_PLUGIN F8 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 NW APARTMENT_LIGHTS_PLUGIN F8 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 SE APARTMENT_LIGHTS_PLUGIN F8 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 NE APARTMENT_LIGHTS_PLUGIN F8 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 N1 APARTMENT_LIGHTS_PLUGIN F8 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 N2 APARTMENT_LIGHTS_PLUGIN F8 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 S1 APARTMENT_LIGHTS_PLUGIN F8 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 S2 APARTMENT_LIGHTS_PLUGIN F8 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 SW APARTMENT_LIGHTS_PLUGIN F9 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 NW APARTMENT_LIGHTS_PLUGIN F9 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 SE APARTMENT_LIGHTS_PLUGIN F9 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 NE APARTMENT_LIGHTS_PLUGIN F9 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 N1 APARTMENT_LIGHTS_PLUGIN F9 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 N2 APARTMENT_LIGHTS_PLUGIN F9 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 S1 APARTMENT_LIGHTS_PLUGIN F9 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 S2 APARTMENT_LIGHTS_PLUGIN F9 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T SW APARTMENT_LIGHTS_PLUGIN T SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T NW APARTMENT_LIGHTS_PLUGIN T NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T SE APARTMENT_LIGHTS_PLUGIN T SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T NE APARTMENT_LIGHTS_PLUGIN T NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T N1 APARTMENT_LIGHTS_PLUGIN T N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T N2 APARTMENT_LIGHTS_PLUGIN T N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T S1 APARTMENT_LIGHTS_PLUGIN T S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T S2 APARTMENT_LIGHTS_PLUGIN T S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
Interior Lighting Total   2.2679 14974.03 33959.19               296.56


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 10364.00 AstronomicalClock -   83.77 83.77 162.97
Exterior Lighting Total 10364.00           162.97



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
CENTRAL BOILER Boiler:HotWater 258651.50 0.75    
CENTRAL TOWER EvaporativeFluidCooler:SingleSpeed 206921.20      


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
HEAT PUMP COOLING MODE AIRLOOP G SW Coil:Cooling:WaterToAirHeatPump:EquationFit   3331.51 2202.53 1128.98 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3281.06 2172.23 1108.82 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP OFFICE Coil:Cooling:WaterToAirHeatPump:EquationFit   4816.47 3203.36 1613.10 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2543.24 1687.17 856.07 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1935.73 1265.39 670.34 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1920.33 1255.04 665.29 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2030.42 1308.69 721.73 0.64 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2108.76 1363.00 745.76 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4026.71 2679.14 1347.56 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3963.59 2638.95 1324.64 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   3771.45 2498.92 1272.53 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3146.76 2101.37 1045.39 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2382.04 1567.84 814.21 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2369.64 1559.50 810.15 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2492.55 1625.60 866.95 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2518.22 1642.95 875.28 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4042.36 2694.22 1348.13 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3983.93 2657.21 1326.72 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   3521.20 2334.69 1186.51 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3184.26 2131.03 1053.22 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2415.59 1593.04 822.55 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2403.42 1584.85 818.57 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2530.52 1653.83 876.69 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2539.45 1659.86 879.59 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4071.42 2716.14 1355.29 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4006.92 2676.09 1330.83 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   3531.51 2343.70 1187.80 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3206.49 2149.29 1057.21 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2441.03 1612.12 828.91 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2429.02 1604.03 824.99 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2556.23 1673.13 883.10 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2562.68 1677.48 885.20 0.65 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4121.80 2752.82 1368.98 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4057.32 2712.78 1344.54 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SE Coil:Cooling:WaterToAirHeatPump:EquationFit   3587.07 2383.83 1203.24 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3255.56 2185.02 1070.53 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2491.53 1647.71 843.83 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2479.65 1639.71 839.95 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2606.07 1708.39 897.68 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2612.18 1712.51 899.67 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4090.88 2734.34 1356.54 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4024.40 2692.98 1331.42 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   3564.39 2370.77 1193.62 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3237.61 2171.66 1065.95 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2461.61 1628.92 832.68 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2449.89 1621.03 828.86 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2577.23 1690.22 887.02 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2583.30 1694.31 888.99 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4088.29 2734.65 1353.64 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4021.23 2692.90 1328.32 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   3568.84 2375.74 1193.11 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3235.61 2172.26 1063.34 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2459.91 1628.97 830.94 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2448.33 1621.17 827.16 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2575.67 1690.27 885.40 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2581.61 1694.33 887.28 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4104.83 2747.63 1357.20 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4037.33 2705.59 1331.73 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   3590.71 2392.26 1198.45 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3332.70 2219.30 1113.40 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2477.23 1641.70 835.53 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2465.79 1633.99 831.80 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2592.36 1702.60 889.76 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2598.03 1706.48 891.54 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4250.32 2848.37 1401.95 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4190.91 2810.71 1380.20 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   3718.63 2480.18 1238.45 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3472.36 2315.25 1157.11 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2617.11 1736.89 880.22 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2605.68 1729.19 876.50 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2702.00 1777.75 924.25 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2707.60 1781.53 926.07 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5405.36 3622.37 1782.98 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5261.53 3528.82 1732.70 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4821.01 3225.05 1595.96 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4510.40 3015.73 1494.67 0.67 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3559.47 2357.55 1201.92 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3555.69 2354.99 1200.70 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3856.69 2557.89 1298.80 0.66 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3861.51 2561.13 1300.38 0.66 0.00    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
None            


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
HEAT PUMP HEATING MODE AIRLOOP G SW Coil:Heating:WaterToAirHeatPump:EquationFit   3331.51 0.00
HEAT PUMP HEATING MODE AIRLOOP G NW Coil:Heating:WaterToAirHeatPump:EquationFit   3281.06 0.00
HEAT PUMP HEATING MODE AIRLOOP OFFICE Coil:Heating:WaterToAirHeatPump:EquationFit   4816.47 0.00
HEAT PUMP HEATING MODE AIRLOOP G NE Coil:Heating:WaterToAirHeatPump:EquationFit   2543.24 0.00
HEAT PUMP HEATING MODE AIRLOOP G N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1935.73 0.00
HEAT PUMP HEATING MODE AIRLOOP G N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1920.33 0.00
HEAT PUMP HEATING MODE AIRLOOP G S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2030.42 0.00
HEAT PUMP HEATING MODE AIRLOOP G S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2108.76 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4026.71 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3963.59 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SE Coil:Heating:WaterToAirHeatPump:EquationFit   3771.45 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3146.76 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2382.04 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2369.64 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2492.55 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2518.22 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4042.36 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NW Coil:Heating:WaterToAirHeatPump:EquationFit   3983.93 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SE Coil:Heating:WaterToAirHeatPump:EquationFit   3521.20 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3184.26 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2415.59 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2403.42 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2530.52 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2539.45 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4071.42 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4006.92 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SE Coil:Heating:WaterToAirHeatPump:EquationFit   3531.51 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3206.49 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2441.03 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2429.02 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2556.23 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2562.68 0.00
HEAT PUMP HEATING MODE AIRLOOP M SW Coil:Heating:WaterToAirHeatPump:EquationFit   4121.80 0.00
HEAT PUMP HEATING MODE AIRLOOP M NW Coil:Heating:WaterToAirHeatPump:EquationFit   4057.32 0.00
HEAT PUMP HEATING MODE AIRLOOP M SE Coil:Heating:WaterToAirHeatPump:EquationFit   3587.07 0.00
HEAT PUMP HEATING MODE AIRLOOP M NE Coil:Heating:WaterToAirHeatPump:EquationFit   3255.56 0.00
HEAT PUMP HEATING MODE AIRLOOP M N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2491.53 0.00
HEAT PUMP HEATING MODE AIRLOOP M N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2479.65 0.00
HEAT PUMP HEATING MODE AIRLOOP M S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2606.07 0.00
HEAT PUMP HEATING MODE AIRLOOP M S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2612.18 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4090.88 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4024.40 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SE Coil:Heating:WaterToAirHeatPump:EquationFit   3564.39 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3237.61 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2461.61 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2449.89 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2577.23 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2583.30 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4088.29 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4021.23 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SE Coil:Heating:WaterToAirHeatPump:EquationFit   3568.84 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3235.61 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2459.91 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2448.33 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2575.67 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2581.61 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4104.83 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4037.33 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SE Coil:Heating:WaterToAirHeatPump:EquationFit   3590.71 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3332.70 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2477.23 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2465.79 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2592.36 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2598.03 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4250.32 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4190.91 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SE Coil:Heating:WaterToAirHeatPump:EquationFit   3718.63 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3472.36 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2617.11 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2605.68 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2702.00 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2707.60 0.00
HEAT PUMP HEATING MODE AIRLOOP T SW Coil:Heating:WaterToAirHeatPump:EquationFit   5405.36 0.00
HEAT PUMP HEATING MODE AIRLOOP T NW Coil:Heating:WaterToAirHeatPump:EquationFit   5261.53 0.00
HEAT PUMP HEATING MODE AIRLOOP T SE Coil:Heating:WaterToAirHeatPump:EquationFit   4821.01 0.00
HEAT PUMP HEATING MODE AIRLOOP T NE Coil:Heating:WaterToAirHeatPump:EquationFit   4510.40 0.00
HEAT PUMP HEATING MODE AIRLOOP T N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3559.47 0.00
HEAT PUMP HEATING MODE AIRLOOP T N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3555.69 0.00
HEAT PUMP HEATING MODE AIRLOOP T S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3856.69 0.00
HEAT PUMP HEATING MODE AIRLOOP T S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3861.51 0.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW Coil:Heating:Electric   2461.24 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW Coil:Heating:Electric   2460.11 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE Coil:Heating:Electric   3141.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE Coil:Heating:Electric   2456.67 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 Coil:Heating:Electric   1835.78 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 Coil:Heating:Electric   1835.69 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 Coil:Heating:Electric   1833.23 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 Coil:Heating:Electric   1839.42 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW Coil:Heating:Electric   2399.64 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW Coil:Heating:Electric   2394.45 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE Coil:Heating:Electric   2414.91 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE Coil:Heating:Electric   2390.93 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 Coil:Heating:Electric   1626.68 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 Coil:Heating:Electric   1626.59 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 Coil:Heating:Electric   1634.55 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 Coil:Heating:Electric   1635.71 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW Coil:Heating:Electric   2388.67 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW Coil:Heating:Electric   2385.15 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE Coil:Heating:Electric   2387.87 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE Coil:Heating:Electric   2382.24 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 Coil:Heating:Electric   1588.37 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 Coil:Heating:Electric   1588.29 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 Coil:Heating:Electric   1592.58 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 Coil:Heating:Electric   1592.70 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW Coil:Heating:Electric   2423.32 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW Coil:Heating:Electric   2421.20 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE Coil:Heating:Electric   2421.22 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE Coil:Heating:Electric   2418.88 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 Coil:Heating:Electric   1600.81 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 Coil:Heating:Electric   1600.75 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 Coil:Heating:Electric   1603.37 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 Coil:Heating:Electric   1603.34 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW Coil:Heating:Electric   2438.78 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW Coil:Heating:Electric   2436.67 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE Coil:Heating:Electric   2437.02 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE Coil:Heating:Electric   2434.88 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 Coil:Heating:Electric   1599.56 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 Coil:Heating:Electric   1599.52 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 Coil:Heating:Electric   1602.09 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 Coil:Heating:Electric   1602.04 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW Coil:Heating:Electric   2513.61 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW Coil:Heating:Electric   2513.07 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE Coil:Heating:Electric   2512.30 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE Coil:Heating:Electric   2511.76 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 Coil:Heating:Electric   1657.05 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 Coil:Heating:Electric   1657.02 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 Coil:Heating:Electric   1657.94 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 Coil:Heating:Electric   1657.91 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW Coil:Heating:Electric   2563.07 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW Coil:Heating:Electric   2562.98 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE Coil:Heating:Electric   2562.19 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE Coil:Heating:Electric   2562.10 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 Coil:Heating:Electric   1692.83 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 Coil:Heating:Electric   1692.80 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 Coil:Heating:Electric   1693.22 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 Coil:Heating:Electric   1693.20 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW Coil:Heating:Electric   2616.62 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW Coil:Heating:Electric   2616.75 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE Coil:Heating:Electric   2616.15 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE Coil:Heating:Electric   2616.27 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 Coil:Heating:Electric   1734.17 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 Coil:Heating:Electric   1734.16 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 Coil:Heating:Electric   1734.34 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 Coil:Heating:Electric   1734.33 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW Coil:Heating:Electric   2783.15 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW Coil:Heating:Electric   2781.30 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE Coil:Heating:Electric   2783.04 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE Coil:Heating:Electric   2781.20 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 Coil:Heating:Electric   1879.90 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 Coil:Heating:Electric   1879.90 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 Coil:Heating:Electric   1881.61 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 Coil:Heating:Electric   1881.60 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW Coil:Heating:Electric   3352.96 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW Coil:Heating:Electric   3357.81 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE Coil:Heating:Electric   3353.16 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE Coil:Heating:Electric   3358.01 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 Coil:Heating:Electric   2497.15 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 Coil:Heating:Electric   2497.15 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 Coil:Heating:Electric   2489.37 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 Coil:Heating:Electric   2489.38 1.00


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
AIRLOOP G SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 283.67 1160.84 1.00 General
AIRLOOP G NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 280.68 1160.84 1.00 General
AIRLOOP OFFICE SUPPLY FAN Fan:OnOff 0.54 622.50 0.36 415.65 1160.84 1.00 General
AIRLOOP G NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 216.84 1160.84 1.00 General
AIRLOOP G N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 159.09 1160.84 1.00 General
AIRLOOP G N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 157.69 1160.84 1.00 General
AIRLOOP G S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 160.43 1160.84 1.00 General
AIRLOOP G S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 167.96 1160.84 1.00 General
AIRLOOP F2 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 349.28 1160.84 1.00 General
AIRLOOP F2 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 344.60 1160.84 1.00 General
AIRLOOP F2 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 322.73 1160.84 1.00 General
AIRLOOP F2 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 273.59 1160.84 1.00 General
AIRLOOP F2 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 199.67 1160.84 1.00 General
AIRLOOP F2 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 198.54 1160.84 1.00 General
AIRLOOP F2 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 203.44 1160.84 1.00 General
AIRLOOP F2 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 205.79 1160.84 1.00 General
AIRLOOP F3 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 351.58 1160.84 1.00 General
AIRLOOP F3 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 347.34 1160.84 1.00 General
AIRLOOP F3 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 300.64 1160.84 1.00 General
AIRLOOP F3 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 277.87 1160.84 1.00 General
AIRLOOP F3 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 203.23 1160.84 1.00 General
AIRLOOP F3 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 202.12 1160.84 1.00 General
AIRLOOP F3 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 207.40 1160.84 1.00 General
AIRLOOP F3 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 208.22 1160.84 1.00 General
AIRLOOP F4 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 354.40 1160.84 1.00 General
AIRLOOP F4 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 350.09 1160.84 1.00 General
AIRLOOP F4 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 301.80 1160.84 1.00 General
AIRLOOP F4 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 280.53 1160.84 1.00 General
AIRLOOP F4 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 205.93 1160.84 1.00 General
AIRLOOP F4 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 204.83 1160.84 1.00 General
AIRLOOP F4 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 210.12 1160.84 1.00 General
AIRLOOP F4 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 210.71 1160.84 1.00 General
AIRLOOP M SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 359.54 1160.84 1.00 General
AIRLOOP M NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 355.24 1160.84 1.00 General
AIRLOOP M SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 307.40 1160.84 1.00 General
AIRLOOP M NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 285.54 1160.84 1.00 General
AIRLOOP M N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 210.84 1160.84 1.00 General
AIRLOOP M N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 209.76 1160.84 1.00 General
AIRLOOP M S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 214.98 1160.84 1.00 General
AIRLOOP M S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 215.54 1160.84 1.00 General
AIRLOOP F6 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 357.15 1160.84 1.00 General
AIRLOOP F6 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 352.67 1160.84 1.00 General
AIRLOOP F6 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 305.75 1160.84 1.00 General
AIRLOOP F6 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 283.10 1160.84 1.00 General
AIRLOOP F6 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 208.37 1160.84 1.00 General
AIRLOOP F6 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 207.30 1160.84 1.00 General
AIRLOOP F6 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 212.59 1160.84 1.00 General
AIRLOOP F6 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 213.14 1160.84 1.00 General
AIRLOOP F7 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 357.31 1160.84 1.00 General
AIRLOOP F7 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 352.77 1160.84 1.00 General
AIRLOOP F7 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 306.53 1160.84 1.00 General
AIRLOOP F7 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 283.29 1160.84 1.00 General
AIRLOOP F7 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 208.44 1160.84 1.00 General
AIRLOOP F7 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 207.38 1160.84 1.00 General
AIRLOOP F7 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 212.66 1160.84 1.00 General
AIRLOOP F7 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 213.21 1160.84 1.00 General
AIRLOOP F8 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 359.18 1160.84 1.00 General
AIRLOOP F8 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 354.60 1160.84 1.00 General
AIRLOOP F8 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.27 308.87 1160.84 1.00 General
AIRLOOP F8 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 285.63 1160.84 1.00 General
AIRLOOP F8 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 210.23 1160.84 1.00 General
AIRLOOP F8 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 209.18 1160.84 1.00 General
AIRLOOP F8 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 214.39 1160.84 1.00 General
AIRLOOP F8 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 214.91 1160.84 1.00 General
AIRLOOP F9 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 373.35 1160.84 1.00 General
AIRLOOP F9 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 369.02 1160.84 1.00 General
AIRLOOP F9 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 320.92 1160.84 1.00 General
AIRLOOP F9 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 298.76 1160.84 1.00 General
AIRLOOP F9 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 223.20 1160.84 1.00 General
AIRLOOP F9 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 222.16 1160.84 1.00 General
AIRLOOP F9 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 224.62 1160.84 1.00 General
AIRLOOP F9 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 225.14 1160.84 1.00 General
AIRLOOP T SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.41 477.50 1160.84 1.00 General
AIRLOOP T NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.40 465.46 1160.84 1.00 General
AIRLOOP T SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.36 422.45 1160.84 1.00 General
AIRLOOP T NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.34 393.93 1160.84 1.00 General
AIRLOOP T N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 303.41 1160.84 1.00 General
AIRLOOP T N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 303.06 1160.84 1.00 General
AIRLOOP T S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 330.66 1160.84 1.00 General
AIRLOOP T S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.29 331.10 1160.84 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
SHWSYS1 PUMP Pump:ConstantSpeed Intermittent 29891.00 0.0003 36.93 127739.32 0.30
PLANT CIRC PUMP Pump:ConstantSpeed Intermittent 224180.02 0.0056 1796.59 319344.75 0.90


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
SHWSYS1 WATER HEATER WaterHeater:Mixed 2.27 175842.64 0.80 0.00 0.00



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 2255.34 2706.41 0.204 0.244 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 36.80 0.00682
G NW APARTMENT 2231.55 2677.86 0.201 0.242 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 35.95 0.00682
OFFICE 3304.73 3965.68 0.298 0.358 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 11:15:00 35.44 0.00682
G NE APARTMENT 1723.97 2068.77 0.156 0.187 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 10:45:00 34.62 0.00682
G N1 APARTMENT 1264.83 1517.79 0.114 0.137 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 34.49 0.00682
G N2 APARTMENT 1253.71 1504.45 0.113 0.136 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 34.49 0.00682
G S1 APARTMENT 1275.49 1530.59 0.115 0.138 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
G S2 APARTMENT 1335.36 1602.44 0.121 0.145 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 37.94 0.00682
F2 SW APARTMENT 2777.00 3332.40 0.251 0.301 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 16:45:00 36.54 0.00682
F2 NW APARTMENT 2739.78 3287.74 0.247 0.297 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 35.95 0.00682
F2 SE APARTMENT 2565.93 3079.12 0.232 0.278 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 37.94 0.00682
F2 NE APARTMENT 2175.21 2610.25 0.196 0.236 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 10:45:00 34.62 0.00682
F2 N1 APARTMENT 1587.47 1904.97 0.143 0.172 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 34.98 0.00682
F2 N2 APARTMENT 1578.48 1894.18 0.143 0.171 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 34.98 0.00682
F2 S1 APARTMENT 1617.47 1940.97 0.146 0.175 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
F2 S2 APARTMENT 1636.13 1963.35 0.148 0.177 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
F3 SW APARTMENT 2795.31 3354.38 0.252 0.303 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 16:45:00 36.54 0.00682
F3 NW APARTMENT 2761.55 3313.86 0.249 0.299 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 35.95 0.00682
F3 SE APARTMENT 2390.29 2868.35 0.216 0.259 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 37.94 0.00682
F3 NE APARTMENT 2209.23 2651.07 0.199 0.239 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 10:45:00 34.62 0.00682
F3 N1 APARTMENT 1615.80 1938.96 0.146 0.175 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 34.98 0.00682
F3 N2 APARTMENT 1606.97 1928.36 0.145 0.174 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 34.98 0.00682
F3 S1 APARTMENT 1648.97 1978.76 0.149 0.179 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
F3 S2 APARTMENT 1655.45 1986.54 0.149 0.179 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
F4 SW APARTMENT 2817.71 3381.25 0.254 0.305 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 36.80 0.00682
F4 NW APARTMENT 2783.48 3340.18 0.251 0.302 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 35.95 0.00682
F4 SE APARTMENT 2399.54 2879.45 0.217 0.260 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
F4 NE APARTMENT 2230.41 2676.49 0.201 0.242 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 10:45:00 34.62 0.00682
F4 N1 APARTMENT 1637.24 1964.68 0.148 0.177 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 34.98 0.00682
F4 N2 APARTMENT 1628.51 1954.21 0.147 0.176 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 34.98 0.00682
F4 S1 APARTMENT 1670.57 2004.69 0.151 0.181 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
F4 S2 APARTMENT 1675.26 2010.31 0.151 0.182 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
M SW APARTMENT 2858.63 3430.36 0.258 0.310 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 36.80 0.00682
M NW APARTMENT 2824.41 3389.30 0.255 0.306 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 35.95 0.00682
M SE APARTMENT 2444.08 2932.90 0.221 0.265 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
M NE APARTMENT 2270.26 2724.31 0.205 0.246 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 10:45:00 34.62 0.00682
M N1 APARTMENT 1676.32 2011.59 0.151 0.182 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 34.98 0.00682
M N2 APARTMENT 1667.69 2001.23 0.151 0.181 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 34.98 0.00682
M S1 APARTMENT 1709.22 2051.07 0.154 0.185 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
M S2 APARTMENT 1713.66 2056.39 0.155 0.186 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
F6 SW APARTMENT 2839.65 3407.58 0.256 0.308 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 36.80 0.00682
F6 NW APARTMENT 2804.00 3364.80 0.253 0.304 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 35.95 0.00682
F6 SE APARTMENT 2430.93 2917.12 0.219 0.263 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
F6 NE APARTMENT 2250.89 2701.06 0.203 0.244 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 11:00:00 35.11 0.00682
F6 N1 APARTMENT 1656.65 1987.98 0.150 0.179 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 34.98 0.00682
F6 N2 APARTMENT 1648.14 1977.77 0.149 0.179 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 34.98 0.00682
F6 S1 APARTMENT 1690.23 2028.28 0.153 0.183 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
F6 S2 APARTMENT 1694.64 2033.57 0.153 0.184 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
F7 SW APARTMENT 2840.87 3409.05 0.257 0.308 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 36.80 0.00682
F7 NW APARTMENT 2804.82 3365.78 0.253 0.304 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 35.95 0.00682
F7 SE APARTMENT 2437.16 2924.59 0.220 0.264 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
F7 NE APARTMENT 2252.38 2702.86 0.203 0.244 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 11:00:00 35.11 0.00682
F7 N1 APARTMENT 1657.22 1988.67 0.150 0.180 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 34.98 0.00682
F7 N2 APARTMENT 1648.80 1978.56 0.149 0.179 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 34.98 0.00682
F7 S1 APARTMENT 1690.77 2028.93 0.153 0.183 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 38.10 0.00682
F7 S2 APARTMENT 1695.17 2034.20 0.153 0.184 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
F8 SW APARTMENT 2855.73 3426.88 0.258 0.309 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 36.80 0.00682
F8 NW APARTMENT 2819.36 3383.23 0.255 0.305 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 35.95 0.00682
F8 SE APARTMENT 2455.79 2946.95 0.222 0.266 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
F8 NE APARTMENT 2270.95 2725.14 0.205 0.246 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:15:00 37.91 0.00682
F8 N1 APARTMENT 1671.42 2005.71 0.151 0.181 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 34.98 0.00682
F8 N2 APARTMENT 1663.09 1995.71 0.150 0.180 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 34.98 0.00682
F8 S1 APARTMENT 1704.51 2045.41 0.154 0.185 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 38.10 0.00682
F8 S2 APARTMENT 1708.71 2050.45 0.154 0.185 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
F9 SW APARTMENT 2968.40 3562.07 0.268 0.322 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 16:45:00 36.54 0.00682
F9 NW APARTMENT 2933.97 3520.77 0.265 0.318 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 35.95 0.00682
F9 SE APARTMENT 2551.60 3061.92 0.230 0.276 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 38.10 0.00682
F9 NE APARTMENT 2375.42 2850.51 0.214 0.257 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:15:00 37.91 0.00682
F9 N1 APARTMENT 1774.61 2129.53 0.160 0.192 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 34.98 0.00682
F9 N2 APARTMENT 1766.29 2119.55 0.159 0.191 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 34.98 0.00682
F9 S1 APARTMENT 1785.91 2143.10 0.161 0.194 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 38.10 0.00682
F9 S2 APARTMENT 1789.98 2147.98 0.162 0.194 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 38.10 0.00682
T SW APARTMENT 3796.51 4555.81 0.343 0.411 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:45:00 37.52 0.00682
T NW APARTMENT 3700.78 4440.94 0.334 0.401 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 37.06 0.00682
T SE APARTMENT 3358.86 4030.64 0.303 0.364 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
T NE APARTMENT 3132.11 3758.53 0.283 0.339 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 38.10 0.00682
T N1 APARTMENT 2412.33 2894.79 0.218 0.261 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:45:00 38.10 0.00682
T N2 APARTMENT 2409.55 2891.46 0.218 0.261 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:45:00 38.10 0.00682
T S1 APARTMENT 2628.97 3154.76 0.237 0.285 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
T S2 APARTMENT 2632.47 3158.96 0.238 0.285 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1461.83 1754.20 0.075 0.090 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.20 0.00281
G NW APARTMENT 1460.87 1753.04 0.075 0.090 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.20 0.00281
OFFICE 1747.16 2096.60 0.090 0.108 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 18:45:00 -5.20 0.00281
G NE APARTMENT 1457.96 1749.56 0.075 0.090 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.20 0.00281
G N1 APARTMENT 932.90 1119.48 0.048 0.057 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.20 0.00281
G N2 APARTMENT 932.82 1119.39 0.048 0.057 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.20 0.00281
G S1 APARTMENT 930.75 1116.89 0.048 0.057 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.20 0.00281
G S2 APARTMENT 935.98 1123.17 0.048 0.058 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.20 0.00281
F2 SW APARTMENT 1409.75 1691.70 0.072 0.087 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F2 NW APARTMENT 1405.37 1686.44 0.072 0.087 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F2 SE APARTMENT 1422.66 1707.20 0.073 0.088 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F2 NE APARTMENT 1402.39 1682.86 0.072 0.086 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F2 N1 APARTMENT 756.09 907.30 0.039 0.047 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F2 N2 APARTMENT 756.01 907.21 0.039 0.047 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F2 S1 APARTMENT 762.74 915.29 0.039 0.047 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F2 S2 APARTMENT 763.72 916.47 0.039 0.047 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F3 SW APARTMENT 1400.48 1680.58 0.072 0.086 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F3 NW APARTMENT 1397.50 1677.01 0.072 0.086 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F3 SE APARTMENT 1399.81 1679.77 0.072 0.086 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F3 NE APARTMENT 1395.05 1674.06 0.072 0.086 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F3 N1 APARTMENT 723.69 868.43 0.037 0.045 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F3 N2 APARTMENT 723.63 868.35 0.037 0.045 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F3 S1 APARTMENT 727.25 872.70 0.037 0.045 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F3 S2 APARTMENT 727.36 872.83 0.037 0.045 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F4 SW APARTMENT 1429.79 1715.75 0.073 0.088 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F4 NW APARTMENT 1428.00 1713.60 0.073 0.088 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F4 SE APARTMENT 1428.01 1713.62 0.073 0.088 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F4 NE APARTMENT 1426.04 1711.24 0.073 0.088 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F4 N1 APARTMENT 734.22 881.06 0.038 0.045 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F4 N2 APARTMENT 734.16 881.00 0.038 0.045 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F4 S1 APARTMENT 736.38 883.66 0.038 0.045 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F4 S2 APARTMENT 736.35 883.62 0.038 0.045 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
M SW APARTMENT 1442.87 1731.44 0.074 0.089 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
M NW APARTMENT 1441.08 1729.30 0.074 0.089 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
M SE APARTMENT 1441.38 1729.65 0.074 0.089 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
M NE APARTMENT 1439.57 1727.48 0.074 0.089 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
M N1 APARTMENT 733.17 879.80 0.038 0.045 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
M N2 APARTMENT 733.13 879.75 0.038 0.045 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
M S1 APARTMENT 735.30 882.36 0.038 0.045 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
M S2 APARTMENT 735.26 882.31 0.038 0.045 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F6 SW APARTMENT 1506.15 1807.38 0.077 0.093 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F6 NW APARTMENT 1505.69 1806.83 0.077 0.093 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F6 SE APARTMENT 1505.04 1806.05 0.077 0.093 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F6 NE APARTMENT 1504.58 1805.50 0.077 0.093 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F6 N1 APARTMENT 781.78 938.14 0.040 0.048 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F6 N2 APARTMENT 781.75 938.11 0.040 0.048 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F6 S1 APARTMENT 782.53 939.04 0.040 0.048 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F6 S2 APARTMENT 782.50 939.01 0.040 0.048 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F7 SW APARTMENT 1547.97 1857.57 0.079 0.095 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F7 NW APARTMENT 1547.90 1857.48 0.079 0.095 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F7 SE APARTMENT 1547.23 1856.68 0.079 0.095 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F7 NE APARTMENT 1547.16 1856.59 0.079 0.095 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F7 N1 APARTMENT 812.04 974.45 0.042 0.050 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F7 N2 APARTMENT 812.02 974.42 0.042 0.050 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F7 S1 APARTMENT 812.37 974.85 0.042 0.050 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F7 S2 APARTMENT 812.35 974.82 0.042 0.050 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F8 SW APARTMENT 1593.27 1911.92 0.082 0.098 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F8 NW APARTMENT 1593.37 1912.05 0.082 0.098 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F8 SE APARTMENT 1592.87 1911.44 0.082 0.098 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F8 NE APARTMENT 1592.97 1911.57 0.082 0.098 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F8 N1 APARTMENT 847.00 1016.40 0.043 0.052 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F8 N2 APARTMENT 846.99 1016.39 0.043 0.052 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F8 S1 APARTMENT 847.14 1016.57 0.043 0.052 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F8 S2 APARTMENT 847.13 1016.56 0.043 0.052 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F9 SW APARTMENT 1734.09 2080.91 0.089 0.107 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F9 NW APARTMENT 1732.53 2079.04 0.089 0.107 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F9 SE APARTMENT 1734.00 2080.80 0.089 0.107 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F9 NE APARTMENT 1732.44 2078.93 0.089 0.107 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F9 N1 APARTMENT 970.24 1164.29 0.050 0.060 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F9 N2 APARTMENT 970.24 1164.28 0.050 0.060 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F9 S1 APARTMENT 971.68 1166.02 0.050 0.060 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
F9 S2 APARTMENT 971.68 1166.01 0.050 0.060 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
T SW APARTMENT 2215.96 2659.15 0.114 0.136 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
T NW APARTMENT 2220.06 2664.07 0.114 0.137 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
T SE APARTMENT 2216.13 2659.36 0.114 0.136 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
T NE APARTMENT 2220.23 2664.28 0.114 0.137 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
T N1 APARTMENT 1492.22 1790.66 0.077 0.092 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
T N2 APARTMENT 1492.22 1790.66 0.077 0.092 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
T S1 APARTMENT 1485.64 1782.77 0.076 0.091 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281
T S2 APARTMENT 1485.65 1782.78 0.076 0.091 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -5.20 0.00281


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
AIRLOOP G SW 0.24 0.24 0.09 0.09
AIRLOOP G NW 0.24 0.24 0.09 0.09
AIRLOOP OFFICE 0.36 0.36 0.11 0.11
AIRLOOP G NE 0.19 0.19 0.09 0.09
AIRLOOP G N1 0.14 0.14 0.06 0.06
AIRLOOP G N2 0.14 0.14 0.06 0.06
AIRLOOP G S1 0.14 0.14 0.06 0.06
AIRLOOP G S2 0.14 0.14 0.06 0.06
AIRLOOP F2 SW 0.30 0.30 0.09 0.09
AIRLOOP F2 NW 0.30 0.30 0.09 0.09
AIRLOOP F2 SE 0.28 0.28 0.09 0.09
AIRLOOP F2 NE 0.24 0.24 0.09 0.09
AIRLOOP F2 N1 0.17 0.17 0.05 0.05
AIRLOOP F2 N2 0.17 0.17 0.05 0.05
AIRLOOP F2 S1 0.18 0.18 0.05 0.05
AIRLOOP F2 S2 0.18 0.18 0.05 0.05
AIRLOOP F3 SW 0.30 0.30 0.09 0.09
AIRLOOP F3 NW 0.30 0.30 0.09 0.09
AIRLOOP F3 SE 0.26 0.26 0.09 0.09
AIRLOOP F3 NE 0.24 0.24 0.09 0.09
AIRLOOP F3 N1 0.18 0.18 0.04 0.04
AIRLOOP F3 N2 0.17 0.17 0.04 0.04
AIRLOOP F3 S1 0.18 0.18 0.04 0.04
AIRLOOP F3 S2 0.18 0.18 0.04 0.04
AIRLOOP F4 SW 0.31 0.31 0.09 0.09
AIRLOOP F4 NW 0.30 0.30 0.09 0.09
AIRLOOP F4 SE 0.26 0.26 0.09 0.09
AIRLOOP F4 NE 0.24 0.24 0.09 0.09
AIRLOOP F4 N1 0.18 0.18 0.05 0.05
AIRLOOP F4 N2 0.18 0.18 0.05 0.05
AIRLOOP F4 S1 0.18 0.18 0.05 0.05
AIRLOOP F4 S2 0.18 0.18 0.05 0.05
AIRLOOP M SW 0.31 0.31 0.09 0.09
AIRLOOP M NW 0.31 0.31 0.09 0.09
AIRLOOP M SE 0.26 0.26 0.09 0.09
AIRLOOP M NE 0.25 0.25 0.09 0.09
AIRLOOP M N1 0.18 0.18 0.05 0.05
AIRLOOP M N2 0.18 0.18 0.05 0.05
AIRLOOP M S1 0.19 0.19 0.05 0.05
AIRLOOP M S2 0.19 0.19 0.05 0.05
AIRLOOP F6 SW 0.31 0.31 0.09 0.09
AIRLOOP F6 NW 0.30 0.30 0.09 0.09
AIRLOOP F6 SE 0.26 0.26 0.09 0.09
AIRLOOP F6 NE 0.24 0.24 0.09 0.09
AIRLOOP F6 N1 0.18 0.18 0.05 0.05
AIRLOOP F6 N2 0.18 0.18 0.05 0.05
AIRLOOP F6 S1 0.18 0.18 0.05 0.05
AIRLOOP F6 S2 0.18 0.18 0.05 0.05
AIRLOOP F7 SW 0.31 0.31 0.10 0.10
AIRLOOP F7 NW 0.30 0.30 0.10 0.10
AIRLOOP F7 SE 0.26 0.26 0.10 0.10
AIRLOOP F7 NE 0.24 0.24 0.10 0.10
AIRLOOP F7 N1 0.18 0.18 0.05 0.05
AIRLOOP F7 N2 0.18 0.18 0.05 0.05
AIRLOOP F7 S1 0.18 0.18 0.05 0.05
AIRLOOP F7 S2 0.18 0.18 0.05 0.05
AIRLOOP F8 SW 0.31 0.31 0.10 0.10
AIRLOOP F8 NW 0.31 0.31 0.10 0.10
AIRLOOP F8 SE 0.27 0.27 0.10 0.10
AIRLOOP F8 NE 0.25 0.25 0.10 0.10
AIRLOOP F8 N1 0.18 0.18 0.05 0.05
AIRLOOP F8 N2 0.18 0.18 0.05 0.05
AIRLOOP F8 S1 0.18 0.18 0.05 0.05
AIRLOOP F8 S2 0.19 0.19 0.05 0.05
AIRLOOP F9 SW 0.32 0.32 0.11 0.11
AIRLOOP F9 NW 0.32 0.32 0.11 0.11
AIRLOOP F9 SE 0.28 0.28 0.11 0.11
AIRLOOP F9 NE 0.26 0.26 0.11 0.11
AIRLOOP F9 N1 0.19 0.19 0.06 0.06
AIRLOOP F9 N2 0.19 0.19 0.06 0.06
AIRLOOP F9 S1 0.19 0.19 0.06 0.06
AIRLOOP F9 S2 0.19 0.19 0.06 0.06
AIRLOOP T SW 0.41 0.41 0.14 0.14
AIRLOOP T NW 0.40 0.40 0.14 0.14
AIRLOOP T SE 0.36 0.36 0.14 0.14
AIRLOOP T NE 0.34 0.34 0.14 0.14
AIRLOOP T N1 0.26 0.26 0.09 0.09
AIRLOOP T N2 0.26 0.26 0.09 0.09
AIRLOOP T S1 0.28 0.28 0.09 0.09
AIRLOOP T S2 0.29 0.29 0.09 0.09



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 3364.75 4855.00 641.50
G NW APARTMENT 3200.25 5620.75 756.50
OFFICE 1151.50 333.50 2.50
G NE APARTMENT 3226.75 5625.25 761.75
G N1 APARTMENT 2986.00 6028.75 896.50
G N2 APARTMENT 2985.75 6028.25 895.50
G S1 APARTMENT 3168.50 5200.25 742.00
G S2 APARTMENT 3203.50 5101.75 726.50
F2 SW APARTMENT 3969.00 3211.25 417.50
F2 NW APARTMENT 3501.00 4639.25 486.25
F2 SE APARTMENT 4116.00 2815.50 348.50
F2 NE APARTMENT 3550.00 4651.50 493.00
F2 N1 APARTMENT 3325.75 4936.75 587.50
F2 N2 APARTMENT 3321.00 4942.25 586.50
F2 S1 APARTMENT 3892.75 3058.25 473.50
F2 S2 APARTMENT 3910.25 2999.75 469.25
F3 SW APARTMENT 4068.25 2920.25 412.75
F3 NW APARTMENT 3569.75 4485.00 477.00
F3 SE APARTMENT 4111.25 2829.75 388.75
F3 NE APARTMENT 3607.00 4507.50 481.75
F3 N1 APARTMENT 3434.00 4677.00 568.50
F3 N2 APARTMENT 3432.75 4680.25 569.25
F3 S1 APARTMENT 4086.50 2598.75 462.25
F3 S2 APARTMENT 4089.75 2585.25 461.75
F4 SW APARTMENT 4067.25 2913.50 427.00
F4 NW APARTMENT 3572.00 4466.00 482.75
F4 SE APARTMENT 4089.00 2866.00 407.00
F4 NE APARTMENT 3610.00 4500.00 492.75
F4 N1 APARTMENT 3448.25 4624.75 565.25
F4 N2 APARTMENT 3446.00 4628.50 568.50
F4 S1 APARTMENT 4112.00 2527.50 464.00
F4 S2 APARTMENT 4112.50 2528.00 465.50
M SW APARTMENT 4064.25 2948.50 428.75
M NW APARTMENT 3579.25 4458.25 476.25
M SE APARTMENT 4087.75 2895.50 405.50
M NE APARTMENT 3614.00 4501.25 489.75
M N1 APARTMENT 3459.25 4594.50 551.75
M N2 APARTMENT 3458.25 4600.50 552.25
M S1 APARTMENT 4119.50 2526.00 457.50
M S2 APARTMENT 4116.75 2526.00 458.50
F6 SW APARTMENT 3975.00 3174.75 457.75
F6 NW APARTMENT 3523.50 4572.75 502.50
F6 SE APARTMENT 3986.00 3115.25 439.00
F6 NE APARTMENT 3566.00 4603.25 517.25
F6 N1 APARTMENT 3397.00 4716.75 586.00
F6 N2 APARTMENT 3397.50 4724.25 587.00
F6 S1 APARTMENT 4008.25 2767.75 486.75
F6 S2 APARTMENT 4005.25 2759.75 486.25
F7 SW APARTMENT 3927.00 3321.00 471.75
F7 NW APARTMENT 3496.50 4642.00 516.75
F7 SE APARTMENT 3934.50 3268.00 452.25
F7 NE APARTMENT 3531.00 4669.00 538.00
F7 N1 APARTMENT 3361.00 4797.00 601.25
F7 N2 APARTMENT 3359.50 4803.00 600.25
F7 S1 APARTMENT 3940.00 2931.50 502.00
F7 S2 APARTMENT 3936.00 2933.25 502.75
F8 SW APARTMENT 3881.75 3446.25 480.25
F8 NW APARTMENT 3476.50 4693.00 532.25
F8 SE APARTMENT 3889.25 3393.75 461.00
F8 NE APARTMENT 3509.25 4708.25 534.00
F8 N1 APARTMENT 3336.75 4843.75 604.75
F8 N2 APARTMENT 3336.25 4851.75 605.75
F8 S1 APARTMENT 3884.50 3086.25 511.00
F8 S2 APARTMENT 3882.50 3085.50 510.50
F9 SW APARTMENT 3840.50 3580.75 475.00
F9 NW APARTMENT 3487.25 4724.25 538.25
F9 SE APARTMENT 3844.25 3533.75 455.50
F9 NE APARTMENT 3527.50 4736.00 538.75
F9 N1 APARTMENT 3337.50 4864.50 585.75
F9 N2 APARTMENT 3334.50 4869.50 586.00
F9 S1 APARTMENT 3821.25 3278.00 497.75
F9 S2 APARTMENT 3820.50 3273.00 496.50
T SW APARTMENT 4232.00 3880.50 631.75
T NW APARTMENT 3849.50 4821.75 848.75
T SE APARTMENT 4294.50 3808.75 631.00
T NE APARTMENT 3893.25 4822.00 836.25
T N1 APARTMENT 3567.00 4970.50 695.50
T N2 APARTMENT 3569.50 4976.25 698.75
T S1 APARTMENT 4062.75 3725.75 547.50
T S2 APARTMENT 4069.50 3723.00 547.00
G CORRIDOR 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00
Facility 5140.25 6080.50 1242.25
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 1.50 13.00 1.50 13.00
G NW APARTMENT 0.00 21.25 0.00 21.25
OFFICE 2.25 7.25 0.00 6.00
G NE APARTMENT 1.25 30.25 1.25 30.25
G N1 APARTMENT 9.25 32.50 9.25 32.50
G N2 APARTMENT 8.00 33.50 8.00 33.50
G S1 APARTMENT 1.25 87.25 1.25 87.25
G S2 APARTMENT 1.50 69.25 1.50 69.25
F2 SW APARTMENT 0.50 18.00 0.50 18.00
F2 NW APARTMENT 0.25 19.75 0.25 19.75
F2 SE APARTMENT 1.00 7.25 1.00 7.25
F2 NE APARTMENT 0.25 31.00 0.25 31.00
F2 N1 APARTMENT 4.50 26.75 4.50 26.75
F2 N2 APARTMENT 4.50 26.75 4.50 26.75
F2 S1 APARTMENT 0.00 116.50 0.00 116.50
F2 S2 APARTMENT 0.00 108.50 0.00 108.50
F3 SW APARTMENT 0.25 23.00 0.25 23.00
F3 NW APARTMENT 0.25 22.00 0.25 22.00
F3 SE APARTMENT 0.75 38.50 0.75 38.50
F3 NE APARTMENT 0.25 43.50 0.25 43.50
F3 N1 APARTMENT 2.25 34.75 2.25 34.75
F3 N2 APARTMENT 2.25 35.25 2.25 35.25
F3 S1 APARTMENT 0.00 129.25 0.00 129.25
F3 S2 APARTMENT 0.25 128.25 0.25 128.25
F4 SW APARTMENT 0.25 23.75 0.25 23.75
F4 NW APARTMENT 0.00 23.00 0.00 23.00
F4 SE APARTMENT 0.25 38.25 0.25 38.25
F4 NE APARTMENT 1.00 52.25 1.00 52.25
F4 N1 APARTMENT 2.75 37.50 2.75 37.50
F4 N2 APARTMENT 3.25 39.25 3.25 39.25
F4 S1 APARTMENT 0.00 125.00 0.00 125.00
F4 S2 APARTMENT 0.00 124.00 0.00 124.00
M SW APARTMENT 0.75 23.00 0.75 23.00
M NW APARTMENT 0.00 24.50 0.00 24.50
M SE APARTMENT 0.25 32.25 0.25 32.25
M NE APARTMENT 0.75 59.50 0.75 59.50
M N1 APARTMENT 1.75 39.50 1.75 39.50
M N2 APARTMENT 1.50 42.00 1.50 42.00
M S1 APARTMENT 0.25 120.25 0.25 120.25
M S2 APARTMENT 0.25 117.00 0.25 117.00
F6 SW APARTMENT 0.00 23.75 0.00 23.75
F6 NW APARTMENT 0.00 25.50 0.00 25.50
F6 SE APARTMENT 1.00 30.25 1.00 30.25
F6 NE APARTMENT 0.00 63.25 0.00 63.25
F6 N1 APARTMENT 2.25 42.00 2.25 42.00
F6 N2 APARTMENT 2.25 44.25 2.25 44.25
F6 S1 APARTMENT 0.00 114.00 0.00 114.00
F6 S2 APARTMENT 0.00 114.00 0.00 114.00
F7 SW APARTMENT 0.00 23.75 0.00 23.75
F7 NW APARTMENT 0.00 26.00 0.00 26.00
F7 SE APARTMENT 0.25 28.25 0.25 28.25
F7 NE APARTMENT 0.25 67.75 0.25 67.75
F7 N1 APARTMENT 2.75 43.00 2.75 43.00
F7 N2 APARTMENT 2.75 45.25 2.75 45.25
F7 S1 APARTMENT 0.00 109.75 0.00 109.75
F7 S2 APARTMENT 0.00 109.50 0.00 109.50
F8 SW APARTMENT 0.00 23.75 0.00 23.75
F8 NW APARTMENT 0.00 26.25 0.00 26.25
F8 SE APARTMENT 0.50 26.75 0.50 26.75
F8 NE APARTMENT 0.25 51.50 0.25 51.50
F8 N1 APARTMENT 3.00 44.50 3.00 44.50
F8 N2 APARTMENT 3.50 46.25 3.50 46.25
F8 S1 APARTMENT 0.50 104.75 0.50 104.75
F8 S2 APARTMENT 0.25 102.50 0.25 102.50
F9 SW APARTMENT 0.25 20.25 0.25 20.25
F9 NW APARTMENT 0.00 25.75 0.00 25.75
F9 SE APARTMENT 0.50 18.50 0.50 18.50
F9 NE APARTMENT 0.25 44.25 0.25 44.25
F9 N1 APARTMENT 2.25 42.00 2.25 42.00
F9 N2 APARTMENT 2.75 42.25 2.75 42.25
F9 S1 APARTMENT 0.25 82.50 0.25 82.50
F9 S2 APARTMENT 0.25 82.00 0.25 82.00
T SW APARTMENT 0.00 12.00 0.00 12.00
T NW APARTMENT 0.00 20.75 0.00 20.75
T SE APARTMENT 0.00 12.50 0.00 12.50
T NE APARTMENT 0.00 15.75 0.00 15.75
T N1 APARTMENT 0.00 11.50 0.00 11.50
T N2 APARTMENT 0.00 10.75 0.00 10.75
T S1 APARTMENT 0.00 46.25 0.00 46.25
T S2 APARTMENT 0.25 45.50 0.25 45.50
G CORRIDOR 0.00 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
Facility 66.75 246.25 65.00 245.00
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.354 0.163 0.000 0.346
G NW APARTMENT 1.71 2.50 268.96 0.354 0.163 0.000 0.329
OFFICE 0.94 1.00 268.96 0.519 0.178 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.354 0.163 0.000 0.329
G N1 APARTMENT 1.71 2.50 268.96 0.354 0.098 0.000 0.321
G N2 APARTMENT 1.71 2.50 268.97 0.354 0.098 0.000 0.321
G S1 APARTMENT 1.71 2.50 268.96 0.354 0.098 0.000 0.342
G S2 APARTMENT 1.71 2.50 268.97 0.354 0.098 0.000 0.343
F2 SW APARTMENT 1.71 2.50 268.96 0.355 0.235 0.000 0.406
F2 NW APARTMENT 1.71 2.50 268.96 0.354 0.235 0.000 0.389
F2 SE APARTMENT 1.71 2.50 268.96 0.355 0.235 0.000 0.407
F2 NE APARTMENT 1.71 2.50 268.96 0.354 0.234 0.000 0.388
F2 N1 APARTMENT 1.71 2.50 268.96 0.354 0.141 0.000 0.384
F2 N2 APARTMENT 1.71 2.50 268.97 0.354 0.141 0.000 0.384
F2 S1 APARTMENT 1.71 2.50 268.96 0.355 0.142 0.000 0.404
F2 S2 APARTMENT 1.71 2.50 268.97 0.355 0.142 0.000 0.405
F3 SW APARTMENT 1.71 2.50 268.96 0.355 0.278 0.000 0.448
F3 NW APARTMENT 1.71 2.50 268.96 0.354 0.278 0.000 0.431
F3 SE APARTMENT 1.71 2.50 268.96 0.355 0.278 0.000 0.448
F3 NE APARTMENT 1.71 2.50 268.96 0.354 0.278 0.000 0.430
F3 N1 APARTMENT 1.71 2.50 268.96 0.354 0.167 0.000 0.427
F3 N2 APARTMENT 1.71 2.50 268.97 0.354 0.167 0.000 0.426
F3 S1 APARTMENT 1.71 2.50 268.96 0.355 0.168 0.000 0.447
F3 S2 APARTMENT 1.71 2.50 268.97 0.355 0.168 0.000 0.447
F4 SW APARTMENT 1.71 2.50 268.96 0.355 0.311 0.000 0.466
F4 NW APARTMENT 1.71 2.50 268.96 0.354 0.310 0.000 0.448
F4 SE APARTMENT 1.71 2.50 268.96 0.355 0.311 0.000 0.466
F4 NE APARTMENT 1.71 2.50 268.96 0.354 0.310 0.000 0.447
F4 N1 APARTMENT 1.71 2.50 268.96 0.354 0.187 0.000 0.444
F4 N2 APARTMENT 1.71 2.50 268.97 0.354 0.187 0.000 0.444
F4 S1 APARTMENT 1.71 2.50 268.96 0.355 0.187 0.000 0.465
F4 S2 APARTMENT 1.71 2.50 268.97 0.355 0.187 0.000 0.465
M SW APARTMENT 1.71 2.50 268.96 0.355 0.338 0.000 0.489
M NW APARTMENT 1.71 2.50 268.96 0.354 0.337 0.000 0.470
M SE APARTMENT 1.71 2.50 268.96 0.355 0.338 0.000 0.489
M NE APARTMENT 1.71 2.50 268.96 0.354 0.337 0.000 0.470
M N1 APARTMENT 1.71 2.50 268.96 0.354 0.203 0.000 0.467
M N2 APARTMENT 1.71 2.50 268.97 0.354 0.203 0.000 0.467
M S1 APARTMENT 1.71 2.50 268.96 0.355 0.204 0.000 0.488
M S2 APARTMENT 1.71 2.50 268.97 0.355 0.204 0.000 0.488
F6 SW APARTMENT 1.71 2.50 268.96 0.354 0.361 0.000 0.508
F6 NW APARTMENT 1.71 2.50 268.96 0.354 0.360 0.000 0.489
F6 SE APARTMENT 1.71 2.50 268.96 0.354 0.361 0.000 0.508
F6 NE APARTMENT 1.71 2.50 268.96 0.354 0.360 0.000 0.488
F6 N1 APARTMENT 1.71 2.50 268.96 0.354 0.217 0.000 0.485
F6 N2 APARTMENT 1.71 2.50 268.97 0.354 0.217 0.000 0.485
F6 S1 APARTMENT 1.71 2.50 268.96 0.355 0.218 0.000 0.507
F6 S2 APARTMENT 1.71 2.50 268.97 0.355 0.218 0.000 0.508
F7 SW APARTMENT 1.71 2.50 268.96 0.354 0.381 0.000 0.525
F7 NW APARTMENT 1.71 2.50 268.96 0.354 0.381 0.000 0.505
F7 SE APARTMENT 1.71 2.50 268.96 0.354 0.381 0.000 0.525
F7 NE APARTMENT 1.71 2.50 268.96 0.354 0.380 0.000 0.504
F7 N1 APARTMENT 1.71 2.50 268.96 0.354 0.230 0.000 0.501
F7 N2 APARTMENT 1.71 2.50 268.97 0.354 0.230 0.000 0.501
F7 S1 APARTMENT 1.71 2.50 268.96 0.355 0.230 0.000 0.524
F7 S2 APARTMENT 1.71 2.50 268.97 0.355 0.230 0.000 0.524
F8 SW APARTMENT 1.71 2.50 268.96 0.354 0.399 0.000 0.543
F8 NW APARTMENT 1.71 2.50 268.96 0.354 0.399 0.000 0.522
F8 SE APARTMENT 1.71 2.50 268.96 0.354 0.399 0.000 0.543
F8 NE APARTMENT 1.71 2.50 268.96 0.354 0.399 0.000 0.521
F8 N1 APARTMENT 1.71 2.50 268.96 0.354 0.241 0.000 0.518
F8 N2 APARTMENT 1.71 2.50 268.97 0.354 0.241 0.000 0.518
F8 S1 APARTMENT 1.71 2.50 268.96 0.355 0.241 0.000 0.542
F8 S2 APARTMENT 1.71 2.50 268.97 0.355 0.241 0.000 0.542
F9 SW APARTMENT 1.71 2.50 268.96 0.354 0.416 0.000 0.559
F9 NW APARTMENT 1.71 2.50 268.96 0.354 0.416 0.000 0.537
F9 SE APARTMENT 1.71 2.50 268.96 0.354 0.416 0.000 0.559
F9 NE APARTMENT 1.71 2.50 268.96 0.354 0.416 0.000 0.536
F9 N1 APARTMENT 1.71 2.50 268.96 0.354 0.251 0.000 0.534
F9 N2 APARTMENT 1.71 2.50 268.97 0.354 0.251 0.000 0.534
F9 S1 APARTMENT 1.71 2.50 268.96 0.355 0.251 0.000 0.558
F9 S2 APARTMENT 1.71 2.50 268.97 0.355 0.251 0.000 0.558
T SW APARTMENT 1.71 2.50 268.96 0.354 0.432 0.000 0.571
T NW APARTMENT 1.71 2.50 268.96 0.354 0.431 0.000 0.551
T SE APARTMENT 1.71 2.50 268.96 0.354 0.432 0.000 0.571
T NE APARTMENT 1.71 2.50 268.96 0.354 0.431 0.000 0.551
T N1 APARTMENT 1.71 2.50 268.96 0.354 0.260 0.000 0.547
T N2 APARTMENT 1.71 2.50 268.97 0.354 0.260 0.000 0.548
T S1 APARTMENT 1.71 2.50 268.96 0.354 0.260 0.000 0.570
T S2 APARTMENT 1.71 2.50 268.97 0.354 0.260 0.000 0.570
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
OFFICE 0.94 1.00 268.96 0.506 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
F2 SW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F2 NW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F2 SE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F2 NE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F2 N1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F2 N2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
F2 S1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F2 S2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
F3 SW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F3 NW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F3 SE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F3 NE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F3 N1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F3 N2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
F3 S1 APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F3 S2 APARTMENT 1.71 2.50 268.97 0.345 0.000 0.000 0.000
F4 SW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F4 NW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F4 SE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F4 NE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F4 N1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F4 N2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
F4 S1 APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F4 S2 APARTMENT 1.71 2.50 268.97 0.345 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 0.345 0.000 0.000 0.000
F6 SW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F6 NW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F6 SE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F6 NE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F6 N1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F6 N2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
F6 S1 APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F6 S2 APARTMENT 1.71 2.50 268.97 0.345 0.000 0.000 0.000
F7 SW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F7 NW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F7 SE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F7 NE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F7 N1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F7 N2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
F7 S1 APARTMENT 1.71 2.50 268.96 0.345 0.000 0.000 0.000
F7 S2 APARTMENT 1.71 2.50 268.97 0.345 0.000 0.000 0.000
F8 SW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F8 NW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F8 SE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F8 NE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F8 N1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F8 N2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
F8 S1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F8 S2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
F9 SW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F9 NW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F9 SE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F9 NE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F9 N1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F9 N2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
F9 S1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
F9 S2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.96 0.344 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.344 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Surfaces by Class

Total Outdoors
Wall 420 140
Floor 90 9
Roof 90 9
Internal Mass 80 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 140 140
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 80
Conditioned Zones 80
Unconditioned Zones 10
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 4156
Defaulted Fields 814
Fields with Defaults 11184
Autosized Fields 1293
Autosizable Fields 1630
Autocalculated Fields 907
Autocalculatable Fields 1710



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 3075.86 58861.67 08-FEB-03:15 165905.79 17-JUL-20:00
Electricity:Building 1433.88 25760.85 01-JAN-03:15 70162.48 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity 296.56 6715.87 01-JAN-00:15 14401.37 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 242.55 5824.91 01-JAN-00:15 11484.27 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:OFFICE 39.38 663.42 01-JAN-00:15 2934.49 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 29.88 469.18 01-JAN-00:15 2345.88 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:G CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F2 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F2 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F3 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F3 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F4 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F4 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:M SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M CORRIDOR 32.88 1042.61 01-JAN-00:15 1042.61 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 32.88 1042.61 01-JAN-00:15 1042.61 01-JAN-00:15
Electricity:Zone:F6 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F6 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F7 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F7 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F8 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F8 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F9 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F9 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:T SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T CORRIDOR 179.47 1701.70 01-JAN-00:15 10868.20 01-JAN-07:15
InteriorLights:Electricity:Zone:T CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 54.01 890.97 01-JAN-00:15 2917.11 01-JAN-19:15
InteriorEquipment:Electricity 1137.32 19044.98 01-JAN-03:15 57142.09 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 1137.32 19044.98 01-JAN-03:15 57142.09 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 9.50 194.24 01-JAN-00:15 588.62 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T CORRIDOR 163.03 1180.40 01-JAN-00:15 10346.90 01-JAN-07:15
Fans:Electricity 695.01 22038.65 01-JAN-00:15 22038.65 01-JAN-00:15
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Electricity:HVAC 1398.15 22699.89 08-FEB-03:15 90201.29 05-JUN-17:00
ElectricityProduced:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityProduced:HVAC 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricityProduced 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 3075.86 58861.67 08-FEB-03:15 165905.79 17-JUL-20:00
ElectricityPurchased:Plant 3075.86 58861.67 08-FEB-03:15 165905.79 17-JUL-20:00
Cogeneration:ElectricityPurchased 3075.86 58861.67 08-FEB-03:15 165905.79 17-JUL-20:00
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 3075.86 58861.67 08-FEB-03:15 165905.79 17-JUL-20:00
ElectricityNet:Plant 3075.86 58861.67 08-FEB-03:15 165905.79 17-JUL-20:00
Cogeneration:ElectricityNet 3075.86 58861.67 08-FEB-03:15 165905.79 17-JUL-20:00
ExteriorLights:Electricity 162.97 0.00 01-JAN-07:15 10364.00 01-JAN-00:15
General:ExteriorLights:Electricity 162.97 0.00 01-JAN-07:15 10364.00 01-JAN-00:15
General:Fans:Electricity 695.01 22038.65 01-JAN-00:15 22038.65 01-JAN-00:15
Cooling:Electricity 636.60 0.00 01-JAN-00:15 66257.90 15-JUN-16:00
Heating:Electricity 30.37 0.00 01-JAN-10:45 33976.03 10-APR-17:00
Electricity:Plant 80.85 36.93 16-JAN-17:15 4389.62 20-JUL-16:15
HeatRejection:Electricity 24.02 0.00 01-JAN-00:15 2556.10 20-JUL-16:15
Boiler Parasitic:Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Pumps:Electricity 56.84 36.93 16-JAN-17:15 1833.52 01-JAN-06:15
WIRED_LTG_ELECTRICITY 0.44 0.00 01-JAN-00:15 21.60 01-JAN-19:30
WIRED_INT_EQUIP 979.40 1018.50 01-JAN-00:15 10185.00 01-JAN-07:15


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 1036.49 2357.00 01-JAN-00:15 158857.86 27-DEC-07:30
Gas:Plant 1036.49 2357.00 01-JAN-00:15 158857.86 27-DEC-07:30
WaterSystems:Gas 974.83 2357.00 01-JAN-00:15 77147.37 28-JAN-08:00
Water Heater:WaterSystems:Gas 974.83 2357.00 01-JAN-00:15 77147.37 28-JAN-08:00
Heating:Gas 61.66 0.00 01-JAN-00:15 109879.08 09-FEB-01:15
Boiler:Heating:Gas 61.66 0.00 01-JAN-00:15 109879.08 09-FEB-01:15


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
PlantLoopCoolingDemand:Facility 2608.76 0.00 01-JAN-00:15 311129.53 20-JUL-16:15
PlantLoopCoolingDemand:HVAC 2608.76 0.00 01-JAN-00:15 311129.53 20-JUL-16:15
CoolingCoils:PlantLoopCoolingDemand 2608.76 0.00 01-JAN-00:15 311129.53 20-JUL-16:15


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 6965.27 0.00 01-JAN-02:15 0.00 14-JUN-17:15
Water:Plant 6965.27 0.00 01-JAN-02:15 0.00 14-JUN-17:15
WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
MainsWater:Facility 6965.27 0.00 01-JAN-02:15 0.00 14-JUN-17:15
MainsWater:Plant 6965.27 0.00 01-JAN-02:15 0.00 14-JUN-17:15
WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
sub cat:WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
sub cat:WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
HeatRejection:Water 2186.76 0.00 01-JAN-00:15 0.00 02-JUN-16:15
HeatRejection:MainsWater 2186.76 0.00 01-JAN-00:15 0.00 02-JUN-16:15


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 838.04 368.60 06-AUG-01:15 136859.14 10-APR-17:00
PlantLoopHeatingDemand:Plant 755.89 368.60 06-AUG-01:15 53564.12 01-FEB-07:45
WaterSystems:PlantLoopHeatingDemand 755.89 368.60 06-AUG-01:15 53564.12 01-FEB-07:45
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 4579.04 5769.98 02-MAY-02:00 436158.98 06-JUL-17:15
EnergyTransfer:Building 1656.91 3561.05 06-MAR-22:15 180722.48 05-JUN-17:00
EnergyTransfer:Zone:G SW APARTMENT 16.04 0.00 13-FEB-10:45 2584.55 29-SEP-15:15
Heating:EnergyTransfer 107.26 0.00 21-JAN-11:00 144493.56 10-APR-17:00
Heating:EnergyTransfer:Zone:G SW APARTMENT 1.17 0.00 01-JAN-00:15 956.86 09-FEB-01:00
Cooling:EnergyTransfer 1549.65 0.00 03-JAN-18:30 180722.48 05-JUN-17:00
Cooling:EnergyTransfer:Zone:G SW APARTMENT 14.87 0.00 01-JAN-14:00 2584.55 29-SEP-15:15
EnergyTransfer:Zone:G NW APARTMENT 14.34 0.01 07-MAY-04:30 2426.27 09-JUN-17:30
Heating:EnergyTransfer:Zone:G NW APARTMENT 2.77 0.00 01-JAN-09:00 1179.20 09-FEB-01:00
Cooling:EnergyTransfer:Zone:G NW APARTMENT 11.57 0.00 01-JAN-00:15 2426.27 09-JUN-17:30
EnergyTransfer:Zone:OFFICE 26.74 0.01 06-OCT-05:00 3587.94 29-SEP-13:30
Heating:EnergyTransfer:Zone:OFFICE 0.63 0.00 01-JAN-00:15 798.28 09-FEB-01:00
Cooling:EnergyTransfer:Zone:OFFICE 26.11 0.00 01-JAN-06:30 3587.94 29-SEP-13:30
EnergyTransfer:Zone:G NE APARTMENT 14.14 0.03 10-FEB-23:15 1825.78 07-JUN-09:45
Heating:EnergyTransfer:Zone:G NE APARTMENT 2.42 0.00 01-JAN-08:45 1186.09 09-FEB-01:00
Cooling:EnergyTransfer:Zone:G NE APARTMENT 11.72 0.00 01-JAN-00:15 1825.78 07-JUN-09:45
EnergyTransfer:Zone:G N1 APARTMENT 9.79 0.04 10-DEC-07:00 1353.06 09-JUN-17:30
Heating:EnergyTransfer:Zone:G N1 APARTMENT 1.20 0.00 01-JAN-00:15 1080.23 31-JAN-17:00
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 8.59 0.00 01-JAN-00:30 1353.06 09-JUN-17:30
EnergyTransfer:Zone:G N2 APARTMENT 9.79 0.05 08-FEB-14:30 1341.19 09-JUN-17:30
Heating:EnergyTransfer:Zone:G N2 APARTMENT 1.19 0.00 01-JAN-00:15 1080.93 31-JAN-17:00
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 8.60 0.00 01-JAN-00:30 1341.19 09-JUN-17:30
EnergyTransfer:Zone:G S1 APARTMENT 12.64 0.00 09-APR-23:15 1567.40 30-SEP-11:15
Heating:EnergyTransfer:Zone:G S1 APARTMENT 0.18 0.00 01-JAN-00:15 821.41 06-APR-14:00
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 12.46 0.00 02-JAN-15:30 1567.40 30-SEP-11:15
EnergyTransfer:Zone:G S2 APARTMENT 12.97 0.01 25-MAY-00:30 1624.96 29-SEP-13:00
Heating:EnergyTransfer:Zone:G S2 APARTMENT 0.18 0.00 01-JAN-00:15 755.79 06-APR-14:00
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 12.80 0.00 02-JAN-15:15 1624.96 29-SEP-13:00
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F2 SW APARTMENT 24.28 0.04 13-APR-01:30 3149.17 29-SEP-15:15
Heating:EnergyTransfer:Zone:F2 SW APARTMENT 0.59 0.00 01-JAN-00:15 970.07 26-JAN-00:30
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT 23.69 0.00 01-JAN-14:00 3149.17 29-SEP-15:15
EnergyTransfer:Zone:F2 NW APARTMENT 19.64 0.01 30-OCT-03:45 2944.99 09-JUN-17:15
Heating:EnergyTransfer:Zone:F2 NW APARTMENT 2.06 0.00 01-JAN-00:15 1315.62 09-FEB-01:00
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT 17.57 0.00 01-JAN-02:45 2944.99 09-JUN-17:15
EnergyTransfer:Zone:F2 SE APARTMENT 26.34 0.06 22-MAR-01:45 2842.37 01-OCT-13:15
Heating:EnergyTransfer:Zone:F2 SE APARTMENT 0.39 0.00 01-JAN-00:15 808.90 26-JAN-00:30
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT 25.94 0.00 01-JAN-14:00 2842.37 01-OCT-13:15
EnergyTransfer:Zone:F2 NE APARTMENT 19.66 0.01 29-JAN-12:15 2345.81 07-JUN-09:30
Heating:EnergyTransfer:Zone:F2 NE APARTMENT 1.73 0.00 01-JAN-00:15 1328.10 09-FEB-01:00
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT 17.92 0.00 01-JAN-00:30 2345.81 07-JUN-09:30
EnergyTransfer:Zone:F2 N1 APARTMENT 14.36 0.03 11-JAN-14:30 1717.36 09-JUN-17:30
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT 0.60 0.00 01-JAN-00:15 1185.58 31-JAN-17:00
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT 13.75 0.00 01-JAN-14:00 1717.36 09-JUN-17:30
EnergyTransfer:Zone:F2 N2 APARTMENT 14.37 0.13 24-OCT-13:45 1708.79 09-JUN-17:30
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT 0.61 0.00 01-JAN-00:15 1186.67 31-JAN-17:00
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT 13.76 0.00 01-JAN-14:00 1708.79 09-JUN-17:30
EnergyTransfer:Zone:F2 S1 APARTMENT 20.27 0.04 14-MAR-10:45 2017.71 28-OCT-14:30
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT 0.10 0.00 01-JAN-00:15 702.80 06-APR-14:00
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT 20.17 0.00 02-JAN-16:00 2017.71 28-OCT-14:30
EnergyTransfer:Zone:F2 S2 APARTMENT 20.45 0.04 30-JAN-16:45 2026.96 28-OCT-14:30
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT 0.10 0.00 01-JAN-00:15 659.03 06-APR-14:00
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT 20.34 0.00 01-JAN-15:15 2026.96 28-OCT-14:30
EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F3 SW APARTMENT 25.58 0.05 08-FEB-15:30 3150.81 29-SEP-15:30
Heating:EnergyTransfer:Zone:F3 SW APARTMENT 0.54 0.00 01-JAN-00:15 1081.13 26-JAN-00:30
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT 25.04 0.00 01-JAN-14:00 3150.81 29-SEP-15:30
EnergyTransfer:Zone:F3 NW APARTMENT 20.53 0.01 14-NOV-08:45 2979.01 09-JUN-17:30
Heating:EnergyTransfer:Zone:F3 NW APARTMENT 1.96 0.00 01-JAN-00:15 1458.17 09-FEB-01:00
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT 18.58 0.00 01-JAN-03:00 2979.01 09-JUN-17:30
EnergyTransfer:Zone:F3 SE APARTMENT 26.08 0.05 03-JAN-23:30 2771.02 01-OCT-10:30
Heating:EnergyTransfer:Zone:F3 SE APARTMENT 0.38 0.00 01-JAN-00:15 1046.98 26-JAN-00:30
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT 25.69 0.00 01-JAN-14:00 2771.02 01-OCT-10:30
EnergyTransfer:Zone:F3 NE APARTMENT 20.60 0.00 15-FEB-15:45 2379.35 07-JUN-09:15
Heating:EnergyTransfer:Zone:F3 NE APARTMENT 1.65 0.00 01-JAN-00:15 1472.16 09-FEB-01:00
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT 18.95 0.00 01-JAN-03:30 2379.35 07-JUN-09:15
EnergyTransfer:Zone:F3 N1 APARTMENT 15.46 0.03 25-JAN-01:30 1754.87 09-JUN-17:45
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT 0.52 0.00 01-JAN-00:15 1297.04 31-JAN-17:00
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT 14.94 0.00 01-JAN-14:00 1754.87 09-JUN-17:45
EnergyTransfer:Zone:F3 N2 APARTMENT 15.47 0.12 03-FEB-13:30 1745.71 09-JUN-17:45
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT 0.52 0.00 01-JAN-00:15 1300.54 31-JAN-17:00
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT 14.95 0.00 01-JAN-14:00 1745.71 09-JUN-17:45
EnergyTransfer:Zone:F3 S1 APARTMENT 22.06 0.10 06-OCT-12:00 2059.72 28-OCT-14:15
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT 0.10 0.00 01-JAN-00:15 916.82 06-APR-14:00
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT 21.96 0.00 01-JAN-15:00 2059.72 28-OCT-14:15
EnergyTransfer:Zone:F3 S2 APARTMENT 22.11 0.05 10-DEC-12:15 2066.36 28-OCT-14:15
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT 0.10 0.00 01-JAN-00:15 894.82 06-APR-14:00
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT 22.01 0.00 01-JAN-15:00 2066.36 28-OCT-14:15
EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F4 SW APARTMENT 25.74 0.04 08-OCT-01:30 3161.87 22-OCT-15:00
Heating:EnergyTransfer:Zone:F4 SW APARTMENT 0.58 0.00 01-JAN-00:15 1221.16 26-JAN-00:30
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT 25.16 0.00 01-JAN-14:15 3161.87 22-OCT-15:00
EnergyTransfer:Zone:F4 NW APARTMENT 20.85 0.01 10-OCT-00:15 2988.95 09-JUN-17:30
Heating:EnergyTransfer:Zone:F4 NW APARTMENT 2.07 0.00 01-JAN-00:15 1637.52 09-FEB-01:00
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT 18.78 0.00 01-JAN-03:00 2988.95 09-JUN-17:30
EnergyTransfer:Zone:F4 SE APARTMENT 26.01 0.05 15-OCT-06:30 2777.03 01-OCT-10:30
Heating:EnergyTransfer:Zone:F4 SE APARTMENT 0.44 0.00 01-JAN-00:15 1270.42 10-APR-17:00
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT 25.57 0.00 01-JAN-14:15 2777.03 01-OCT-10:30
EnergyTransfer:Zone:F4 NE APARTMENT 20.89 0.02 05-JAN-15:15 2392.17 07-JUN-09:15
Heating:EnergyTransfer:Zone:F4 NE APARTMENT 1.74 0.00 01-JAN-00:15 1648.70 09-FEB-01:00
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT 19.16 0.00 01-JAN-03:45 2392.17 07-JUN-09:15
EnergyTransfer:Zone:F4 N1 APARTMENT 15.74 0.03 27-JAN-11:45 1773.47 09-JUN-17:45
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT 0.51 0.00 01-JAN-00:15 1358.21 10-APR-17:00
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT 15.23 0.00 01-JAN-14:15 1773.47 09-JUN-17:45
EnergyTransfer:Zone:F4 N2 APARTMENT 15.75 0.00 14-NOV-00:45 1770.08 08-JUN-20:30
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT 0.51 0.00 01-JAN-00:15 1356.71 10-APR-17:00
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT 15.24 0.00 01-JAN-14:15 1770.08 08-JUN-20:30
EnergyTransfer:Zone:F4 S1 APARTMENT 22.42 0.02 10-JAN-14:00 2082.40 03-NOV-14:30
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT 0.11 0.00 01-JAN-00:15 1110.83 10-APR-17:00
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT 22.31 0.00 01-JAN-15:00 2082.40 03-NOV-14:30
EnergyTransfer:Zone:F4 S2 APARTMENT 22.44 0.13 06-OCT-11:45 2086.59 03-NOV-14:30
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT 0.11 0.00 01-JAN-00:15 1109.65 10-APR-17:00
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT 22.33 0.00 01-JAN-15:00 2086.59 03-NOV-14:30
EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M SW APARTMENT 26.00 0.00 24-JAN-14:45 3184.75 22-OCT-15:00
Heating:EnergyTransfer:Zone:M SW APARTMENT 0.66 0.00 01-JAN-00:15 1561.02 10-APR-17:00
Cooling:EnergyTransfer:Zone:M SW APARTMENT 25.34 0.00 01-JAN-14:15 3184.75 22-OCT-15:00
EnergyTransfer:Zone:M NW APARTMENT 21.35 0.01 17-NOV-10:30 3022.28 09-JUN-17:30
Heating:EnergyTransfer:Zone:M NW APARTMENT 2.21 0.00 01-JAN-00:15 1794.59 09-FEB-01:00
Cooling:EnergyTransfer:Zone:M NW APARTMENT 19.13 0.00 01-JAN-02:45 3022.28 09-JUN-17:30
EnergyTransfer:Zone:M SE APARTMENT 26.23 0.03 07-APR-00:30 2813.68 29-SEP-12:00
Heating:EnergyTransfer:Zone:M SE APARTMENT 0.52 0.00 01-JAN-00:15 1625.97 10-APR-17:00
Cooling:EnergyTransfer:Zone:M SE APARTMENT 25.71 0.00 01-JAN-14:15 2813.68 29-SEP-12:00
EnergyTransfer:Zone:M NE APARTMENT 21.37 0.04 14-DEC-13:15 2426.95 07-JUN-09:15
Heating:EnergyTransfer:Zone:M NE APARTMENT 1.87 0.00 01-JAN-00:15 1832.30 10-APR-17:00
Cooling:EnergyTransfer:Zone:M NE APARTMENT 19.51 0.00 01-JAN-03:45 2426.95 07-JUN-09:15
EnergyTransfer:Zone:M N1 APARTMENT 16.17 0.02 30-JAN-16:15 1825.00 08-JUN-20:30
Heating:EnergyTransfer:Zone:M N1 APARTMENT 0.55 0.00 01-JAN-00:15 1657.01 10-APR-17:00
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 15.62 0.00 01-JAN-14:15 1825.00 08-JUN-20:30
EnergyTransfer:Zone:M N2 APARTMENT 16.18 0.05 30-JAN-16:15 1817.25 08-JUN-20:30
Heating:EnergyTransfer:Zone:M N2 APARTMENT 0.55 0.00 01-JAN-00:15 1655.30 10-APR-17:00
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 15.63 0.00 01-JAN-14:15 1817.25 08-JUN-20:30
EnergyTransfer:Zone:M S1 APARTMENT 22.75 0.17 13-MAR-18:30 2123.24 03-NOV-14:30
Heating:EnergyTransfer:Zone:M S1 APARTMENT 0.13 0.00 01-JAN-00:15 1427.62 10-APR-17:00
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 22.62 0.00 01-JAN-14:15 2123.24 03-NOV-14:30
EnergyTransfer:Zone:M S2 APARTMENT 22.76 0.15 06-OCT-11:30 2127.06 03-NOV-14:30
Heating:EnergyTransfer:Zone:M S2 APARTMENT 0.13 0.00 01-JAN-00:15 1426.31 10-APR-17:00
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 22.63 0.00 01-JAN-14:15 2127.06 03-NOV-14:30
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F6 SW APARTMENT 25.16 0.01 26-APR-06:00 3144.48 22-OCT-15:00
Heating:EnergyTransfer:Zone:F6 SW APARTMENT 0.82 0.00 01-JAN-00:15 1937.83 10-APR-17:00
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT 24.34 0.00 01-JAN-14:15 3144.48 22-OCT-15:00
EnergyTransfer:Zone:F6 NW APARTMENT 21.15 0.02 12-DEC-15:45 2990.88 09-JUN-17:30
Heating:EnergyTransfer:Zone:F6 NW APARTMENT 2.59 0.00 01-JAN-00:15 2144.14 10-APR-17:00
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT 18.55 0.00 01-JAN-02:45 2990.88 09-JUN-17:30
EnergyTransfer:Zone:F6 SE APARTMENT 25.35 0.00 28-FEB-16:45 2797.91 29-SEP-12:00
Heating:EnergyTransfer:Zone:F6 SE APARTMENT 0.66 0.00 01-JAN-00:15 1995.32 10-APR-17:00
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT 24.69 0.00 01-JAN-14:15 2797.91 29-SEP-12:00
EnergyTransfer:Zone:F6 NE APARTMENT 21.13 0.01 08-OCT-00:15 2409.07 07-JUN-09:15
Heating:EnergyTransfer:Zone:F6 NE APARTMENT 2.23 0.00 01-JAN-00:15 2192.66 10-APR-17:00
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT 18.90 0.00 01-JAN-01:00 2409.07 07-JUN-09:15
EnergyTransfer:Zone:F6 N1 APARTMENT 15.71 0.01 15-DEC-19:45 1988.89 10-APR-17:00
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT 0.70 0.00 01-JAN-00:15 1988.89 10-APR-17:00
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT 15.00 0.00 01-JAN-14:15 1811.58 09-MAY-20:00
EnergyTransfer:Zone:F6 N2 APARTMENT 15.72 0.01 17-AUG-09:30 1986.72 10-APR-17:00
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT 0.71 0.00 01-JAN-00:15 1986.72 10-APR-17:00
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT 15.01 0.00 01-JAN-14:15 1806.64 09-MAY-20:00
EnergyTransfer:Zone:F6 S1 APARTMENT 21.80 0.12 07-DEC-15:15 2097.94 03-NOV-14:30
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT 0.16 0.00 01-JAN-00:15 1768.84 10-APR-17:00
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT 21.65 0.00 01-JAN-14:15 2097.94 03-NOV-14:30
EnergyTransfer:Zone:F6 S2 APARTMENT 21.81 0.18 13-MAR-12:15 2101.48 03-NOV-14:30
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT 0.16 0.00 01-JAN-00:15 1767.28 10-APR-17:00
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT 21.66 0.00 01-JAN-14:15 2101.48 03-NOV-14:30
EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F7 SW APARTMENT 24.75 0.00 13-JAN-21:45 3124.55 22-OCT-15:00
Heating:EnergyTransfer:Zone:F7 SW APARTMENT 0.97 0.00 01-JAN-00:15 2250.65 10-APR-17:00
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT 23.78 0.00 01-JAN-14:15 3124.55 22-OCT-15:00
EnergyTransfer:Zone:F7 NW APARTMENT 21.23 0.01 01-NOV-04:45 2983.80 09-JUN-17:30
Heating:EnergyTransfer:Zone:F7 NW APARTMENT 2.93 0.00 01-JAN-00:15 2450.58 10-APR-17:00
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT 18.30 0.00 01-JAN-02:45 2983.80 09-JUN-17:30
EnergyTransfer:Zone:F7 SE APARTMENT 24.92 0.00 13-FEB-03:45 2802.95 29-SEP-12:00
Heating:EnergyTransfer:Zone:F7 SE APARTMENT 0.80 0.00 01-JAN-00:15 2302.13 10-APR-17:00
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT 24.12 0.00 01-JAN-14:15 2802.95 29-SEP-12:00
EnergyTransfer:Zone:F7 NE APARTMENT 21.17 0.00 02-JAN-19:45 2493.03 10-APR-17:00
Heating:EnergyTransfer:Zone:F7 NE APARTMENT 2.55 0.00 01-JAN-03:00 2493.03 10-APR-17:00
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT 18.62 0.00 01-JAN-00:15 2410.97 02-JUL-21:00
EnergyTransfer:Zone:F7 N1 APARTMENT 15.56 0.07 07-DEC-13:30 2264.49 10-APR-17:00
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT 0.84 0.00 01-JAN-00:15 2264.49 10-APR-17:00
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT 14.72 0.00 01-JAN-14:15 1820.86 09-MAY-20:00
EnergyTransfer:Zone:F7 N2 APARTMENT 15.57 0.05 21-DEC-02:00 2261.93 10-APR-17:00
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT 0.85 0.00 01-JAN-00:15 2261.93 10-APR-17:00
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT 14.73 0.00 01-JAN-14:15 1812.46 09-MAY-20:00
EnergyTransfer:Zone:F7 S1 APARTMENT 21.28 0.26 08-APR-00:30 2087.42 03-NOV-14:30
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT 0.18 0.00 01-JAN-00:15 2051.91 10-APR-17:00
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT 21.10 0.00 01-JAN-14:15 2087.42 03-NOV-14:30
EnergyTransfer:Zone:F7 S2 APARTMENT 21.29 0.11 04-MAY-04:45 2081.76 03-NOV-14:30
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT 0.18 0.00 01-JAN-00:15 2050.08 10-APR-17:00
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT 21.11 0.00 01-JAN-14:15 2081.76 03-NOV-14:30
EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F8 SW APARTMENT 24.56 0.03 07-OCT-09:30 3111.29 22-OCT-15:00
Heating:EnergyTransfer:Zone:F8 SW APARTMENT 1.14 0.00 01-JAN-00:15 2522.95 10-APR-17:00
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT 23.43 0.00 01-JAN-14:15 3111.29 22-OCT-15:00
EnergyTransfer:Zone:F8 NW APARTMENT 21.49 0.04 15-NOV-02:15 2995.92 06-JUL-16:30
Heating:EnergyTransfer:Zone:F8 NW APARTMENT 3.25 0.00 01-JAN-00:15 2717.46 10-APR-17:00
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT 18.24 0.00 01-JAN-01:00 2995.92 06-JUL-16:30
EnergyTransfer:Zone:F8 SE APARTMENT 24.72 0.02 15-FEB-16:15 2811.32 29-SEP-12:00
Heating:EnergyTransfer:Zone:F8 SE APARTMENT 0.95 0.00 01-JAN-00:15 2569.76 10-APR-17:00
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT 23.77 0.00 01-JAN-14:15 2811.32 29-SEP-12:00
EnergyTransfer:Zone:F8 NE APARTMENT 21.42 0.01 23-JAN-15:45 2755.09 10-APR-17:00
Heating:EnergyTransfer:Zone:F8 NE APARTMENT 2.86 0.00 01-JAN-08:15 2755.09 10-APR-17:00
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT 18.56 0.00 01-JAN-00:15 2474.77 02-JUL-21:00
EnergyTransfer:Zone:F8 N1 APARTMENT 15.60 0.01 14-DEC-00:45 2503.79 10-APR-17:00
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT 0.99 0.00 01-JAN-00:15 2503.79 10-APR-17:00
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT 14.61 0.00 01-JAN-14:00 1832.78 09-MAY-20:00
EnergyTransfer:Zone:F8 N2 APARTMENT 15.61 0.05 12-DEC-23:45 2500.94 10-APR-17:00
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT 0.99 0.00 01-JAN-00:15 2500.94 10-APR-17:00
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT 14.62 0.00 01-JAN-14:00 1824.82 08-JUN-20:30
EnergyTransfer:Zone:F8 S1 APARTMENT 20.95 0.19 08-OCT-09:45 2297.47 10-APR-17:00
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT 0.22 0.00 01-JAN-00:15 2297.47 10-APR-17:00
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT 20.74 0.00 01-JAN-14:15 2067.56 22-OCT-12:30
EnergyTransfer:Zone:F8 S2 APARTMENT 20.96 0.11 14-MAR-10:30 2295.43 10-APR-17:00
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT 0.22 0.00 01-JAN-00:15 2295.43 10-APR-17:00
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT 20.74 0.00 01-JAN-14:15 2072.43 22-OCT-12:30
EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F9 SW APARTMENT 24.99 0.00 12-DEC-21:45 3219.61 22-OCT-15:15
Heating:EnergyTransfer:Zone:F9 SW APARTMENT 1.48 0.00 01-JAN-00:15 2740.94 10-APR-17:00
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT 23.51 0.00 01-JAN-03:00 3219.61 22-OCT-15:15
EnergyTransfer:Zone:F9 NW APARTMENT 22.52 0.02 08-OCT-06:30 3120.85 06-JUL-16:30
Heating:EnergyTransfer:Zone:F9 NW APARTMENT 3.80 0.00 01-JAN-00:30 2933.80 10-APR-17:00
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT 18.72 0.00 01-JAN-00:15 3120.85 06-JUL-16:30
EnergyTransfer:Zone:F9 SE APARTMENT 25.07 0.01 30-NOV-19:30 2836.38 29-SEP-12:00
Heating:EnergyTransfer:Zone:F9 SE APARTMENT 1.25 0.00 01-JAN-00:15 2783.19 10-APR-17:00
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT 23.82 0.00 01-JAN-14:15 2836.38 29-SEP-12:00
EnergyTransfer:Zone:F9 NE APARTMENT 22.34 0.01 22-APR-03:15 2967.72 10-APR-17:00
Heating:EnergyTransfer:Zone:F9 NE APARTMENT 3.35 0.00 01-JAN-08:30 2967.72 10-APR-17:00
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT 18.99 0.00 01-JAN-00:15 2597.62 02-JUL-21:00
EnergyTransfer:Zone:F9 N1 APARTMENT 16.19 0.00 04-MAR-20:00 2698.04 10-APR-17:00
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT 1.26 0.00 01-JAN-00:15 2698.04 10-APR-17:00
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT 14.92 0.00 01-JAN-12:45 1941.29 08-JUN-20:30
EnergyTransfer:Zone:F9 N2 APARTMENT 16.20 0.03 21-MAR-15:15 2694.74 10-APR-17:00
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT 1.27 0.00 01-JAN-00:15 2694.74 10-APR-17:00
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT 14.93 0.00 01-JAN-12:45 1933.73 08-JUN-20:30
EnergyTransfer:Zone:F9 S1 APARTMENT 20.96 0.21 16-JAN-03:00 2493.29 10-APR-17:00
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT 0.29 0.00 01-JAN-00:15 2493.29 10-APR-17:00
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT 20.67 0.00 01-JAN-14:15 2147.04 22-OCT-13:00
EnergyTransfer:Zone:F9 S2 APARTMENT 20.97 0.12 07-DEC-15:00 2490.78 10-APR-17:00
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT 0.29 0.00 01-JAN-00:15 2490.78 10-APR-17:00
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT 20.69 0.00 01-JAN-14:15 2151.61 22-OCT-13:00
EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:T SW APARTMENT 30.67 0.05 14-AUG-02:30 4108.38 01-OCT-14:15
Heating:EnergyTransfer:Zone:T SW APARTMENT 4.62 0.00 01-JAN-08:45 3664.13 10-APR-17:00
Cooling:EnergyTransfer:Zone:T SW APARTMENT 26.05 0.00 01-JAN-00:15 4108.38 01-OCT-14:15
EnergyTransfer:Zone:T NW APARTMENT 28.09 0.09 05-OCT-05:15 3975.83 06-JUL-16:30
Heating:EnergyTransfer:Zone:T NW APARTMENT 7.16 0.00 06-JAN-15:00 3772.25 10-APR-17:00
Cooling:EnergyTransfer:Zone:T NW APARTMENT 20.93 0.00 01-JAN-00:15 3975.83 06-JUL-16:30
EnergyTransfer:Zone:T SE APARTMENT 30.15 0.01 22-OCT-02:30 3764.67 10-APR-17:00
Heating:EnergyTransfer:Zone:T SE APARTMENT 4.19 0.00 01-JAN-08:30 3764.67 10-APR-17:00
Cooling:EnergyTransfer:Zone:T SE APARTMENT 25.96 0.00 01-JAN-00:15 3710.56 01-OCT-12:15
EnergyTransfer:Zone:T NE APARTMENT 27.31 0.01 28-DEC-12:45 3869.10 10-APR-17:00
Heating:EnergyTransfer:Zone:T NE APARTMENT 6.47 0.00 01-JAN-08:45 3869.10 10-APR-17:00
Cooling:EnergyTransfer:Zone:T NE APARTMENT 20.83 0.00 01-JAN-00:15 3284.16 05-JUN-17:00
EnergyTransfer:Zone:T N1 APARTMENT 19.59 0.01 04-JAN-17:00 3487.75 10-APR-17:00
Heating:EnergyTransfer:Zone:T N1 APARTMENT 3.24 0.00 01-JAN-08:45 3487.75 10-APR-17:00
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 16.35 0.00 01-JAN-00:15 2560.58 17-JUN-18:00
EnergyTransfer:Zone:T N2 APARTMENT 19.61 0.00 11-MAR-08:45 3489.39 10-APR-17:00
Heating:EnergyTransfer:Zone:T N2 APARTMENT 3.25 0.00 01-JAN-08:45 3489.39 10-APR-17:00
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 16.36 0.00 01-JAN-00:15 2554.26 17-JUN-18:00
EnergyTransfer:Zone:T S1 APARTMENT 23.48 0.01 05-MAR-01:15 3369.23 10-APR-17:00
Heating:EnergyTransfer:Zone:T S1 APARTMENT 1.51 0.00 01-JAN-00:15 3369.23 10-APR-17:00
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 21.97 0.00 01-JAN-14:30 3059.85 22-OCT-13:15
EnergyTransfer:Zone:T S2 APARTMENT 23.51 0.01 12-NOV-00:15 3371.28 10-APR-17:00
Heating:EnergyTransfer:Zone:T S2 APARTMENT 1.52 0.00 01-JAN-00:15 3371.28 10-APR-17:00
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 22.00 0.00 01-JAN-14:30 3063.77 22-OCT-13:15
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Plant 801.81 368.60 06-AUG-01:15 116382.92 26-JAN-07:15
WaterSystems:EnergyTransfer 755.89 368.60 06-AUG-01:15 53558.64 01-FEB-07:45
sub cat:WaterSystems:EnergyTransfer 755.89 368.60 06-AUG-01:15 53558.64 01-FEB-07:45
EnergyTransfer:HVAC 2120.31 0.00 16-JAN-17:15 246828.89 20-JUL-16:15
CoolingCoils:EnergyTransfer 2013.09 0.00 01-JAN-00:15 246828.89 20-JUL-16:15
HeatingCoils:EnergyTransfer 107.22 0.00 01-JAN-10:45 133253.21 10-APR-17:00
PlantLoopHeatingDemand:HVAC 82.15 0.00 01-JAN-10:45 101490.61 10-APR-17:00
HeatingCoils:PlantLoopHeatingDemand 82.15 0.00 01-JAN-10:45 101490.61 10-APR-17:00
Boilers:EnergyTransfer 45.92 0.00 01-JAN-00:15 82409.31 09-FEB-01:15



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 1.167 -14.871 0.000 0.000 3.702 1.087 12.213 23.177 0.000 0.735 0.001 0.000 -7.451 0.000 -5.651 -14.108
G NW APARTMENT 2.769 -11.569 0.000 0.000 3.755 1.087 12.213 13.146 0.000 0.732 0.000 0.000 -7.441 0.000 -4.993 -9.698
OFFICE 0.631 -26.108 0.000 0.000 0.505 29.882 9.495 23.198 0.000 0.582 0.000 0.000 -7.426 0.000 -2.613 -28.148
G NE APARTMENT 2.419 -11.719 0.000 0.000 3.768 1.087 12.213 13.030 0.000 0.731 0.000 0.000 -7.041 0.000 -4.958 -9.530
G N1 APARTMENT 1.197 -8.591 0.000 0.000 3.772 1.087 12.213 4.706 0.000 0.502 0.000 0.000 -4.522 0.000 -3.771 -6.591
G N2 APARTMENT 1.193 -8.596 0.000 0.000 3.772 1.087 12.213 4.704 0.000 0.502 0.000 0.000 -4.518 0.000 -3.771 -6.585
G S1 APARTMENT 0.178 -12.459 0.000 0.000 3.700 1.087 12.213 14.886 0.000 0.503 0.000 0.000 -4.510 0.000 -4.496 -11.101
G S2 APARTMENT 0.175 -12.797 0.000 0.000 3.694 1.087 12.213 14.866 0.000 0.503 0.000 0.000 -4.525 0.000 -4.544 -10.672
F2 SW APARTMENT 0.591 -23.687 0.000 0.000 3.620 1.087 12.213 22.200 0.000 1.017 0.000 0.000 -8.134 0.000 -7.619 -1.288
F2 NW APARTMENT 2.064 -17.574 0.000 0.000 3.703 1.087 12.213 12.487 0.000 1.011 0.000 0.000 -8.028 0.000 -6.818 -0.145
F2 SE APARTMENT 0.394 -25.943 0.000 0.000 3.613 1.087 12.213 22.222 0.000 1.017 1.116 0.000 -7.998 0.000 -7.719 -0.000
F2 NE APARTMENT 1.734 -17.923 0.000 0.000 3.719 1.087 12.213 12.392 0.000 1.010 0.104 0.000 -7.574 0.000 -6.761 -0.000
F2 N1 APARTMENT 0.604 -13.751 0.000 0.000 3.713 1.087 12.213 4.378 0.000 0.680 1.165 0.000 -4.940 0.000 -5.150 -0.000
F2 N2 APARTMENT 0.606 -13.761 0.000 0.000 3.714 1.087 12.213 4.377 0.000 0.680 1.168 0.000 -4.935 0.000 -5.148 -0.000
F2 S1 APARTMENT 0.103 -20.169 0.000 0.000 3.602 1.087 12.213 14.268 0.000 0.683 0.000 0.000 -4.937 0.000 -6.051 -0.799
F2 S2 APARTMENT 0.103 -20.343 0.000 0.000 3.601 1.087 12.213 14.262 0.000 0.684 0.000 0.000 -4.943 0.000 -6.065 -0.598
F3 SW APARTMENT 0.539 -25.038 0.000 0.000 3.609 1.087 12.213 21.791 0.000 1.222 1.474 0.000 -8.281 0.000 -8.616 -0.000
F3 NW APARTMENT 1.956 -18.576 0.000 0.000 3.694 1.087 12.213 12.236 0.000 1.214 2.140 0.000 -8.191 0.000 -7.772 -0.000
F3 SE APARTMENT 0.384 -25.691 0.000 0.000 3.615 1.087 12.213 21.895 0.000 1.221 1.966 0.000 -8.062 0.000 -8.626 -0.000
F3 NE APARTMENT 1.649 -18.954 0.000 0.000 3.709 1.087 12.213 12.157 0.000 1.212 2.361 0.000 -7.724 0.000 -7.710 -0.000
F3 N1 APARTMENT 0.519 -14.936 0.000 0.000 3.697 1.087 12.213 4.278 0.000 0.823 3.256 0.000 -5.069 0.000 -5.869 0.000
F3 N2 APARTMENT 0.521 -14.945 0.000 0.000 3.698 1.087 12.213 4.277 0.000 0.823 3.257 0.000 -5.064 0.000 -5.867 0.000
F3 S1 APARTMENT 0.096 -21.960 0.000 0.000 3.585 1.087 12.213 14.007 0.000 0.826 1.993 0.000 -5.046 0.000 -6.799 -0.000
F3 S2 APARTMENT 0.096 -22.012 0.000 0.000 3.584 1.087 12.213 14.004 0.000 0.827 2.051 0.000 -5.046 0.000 -6.804 -0.000
F4 SW APARTMENT 0.584 -25.161 0.000 0.000 3.610 1.087 12.213 21.531 0.000 1.348 2.263 0.000 -8.332 0.000 -9.142 -0.000
F4 NW APARTMENT 2.066 -18.779 0.000 0.000 3.692 1.087 12.213 12.085 0.000 1.339 2.851 0.000 -8.261 0.000 -8.292 -0.000
F4 SE APARTMENT 0.441 -25.567 0.000 0.000 3.618 1.087 12.213 21.659 0.000 1.346 2.441 0.000 -8.096 0.000 -9.142 -0.000
F4 NE APARTMENT 1.737 -19.157 0.000 0.000 3.708 1.087 12.213 12.018 0.000 1.335 3.074 0.000 -7.787 0.000 -8.227 -0.000
F4 N1 APARTMENT 0.513 -15.230 0.000 0.000 3.692 1.087 12.213 4.225 0.000 0.904 3.934 0.000 -5.127 0.000 -6.210 0.000
F4 N2 APARTMENT 0.515 -15.238 0.000 0.000 3.693 1.087 12.213 4.223 0.000 0.903 3.934 0.000 -5.122 0.000 -6.208 0.000
F4 S1 APARTMENT 0.108 -22.311 0.000 0.000 3.582 1.087 12.213 13.841 0.000 0.907 2.792 0.000 -5.086 0.000 -7.134 -0.000
F4 S2 APARTMENT 0.108 -22.329 0.000 0.000 3.583 1.087 12.213 13.840 0.000 0.907 2.812 0.000 -5.084 0.000 -7.136 -0.000
M SW APARTMENT 0.661 -25.341 0.000 0.000 3.612 1.087 12.213 21.324 0.000 1.448 3.091 0.000 -8.371 0.000 -9.723 -0.000
M NW APARTMENT 2.213 -19.134 0.000 0.000 3.693 1.087 12.213 11.966 0.000 1.439 3.676 0.000 -8.314 0.000 -8.839 0.000
M SE APARTMENT 0.515 -25.711 0.000 0.000 3.620 1.087 12.213 21.464 0.000 1.447 3.218 0.000 -8.131 0.000 -9.722 -0.000
M NE APARTMENT 1.867 -19.507 0.000 0.000 3.708 1.087 12.213 11.905 0.000 1.434 3.900 0.000 -7.834 0.000 -8.772 0.000
M N1 APARTMENT 0.554 -15.619 0.000 0.000 3.691 1.087 12.213 4.182 0.000 0.968 4.700 0.000 -5.170 0.000 -6.606 0.000
M N2 APARTMENT 0.555 -15.627 0.000 0.000 3.692 1.087 12.213 4.181 0.000 0.967 4.700 0.000 -5.165 0.000 -6.603 0.000
M S1 APARTMENT 0.129 -22.622 0.000 0.000 3.583 1.087 12.213 13.710 0.000 0.972 3.598 0.000 -5.114 0.000 -7.555 -0.001
M S2 APARTMENT 0.129 -22.633 0.000 0.000 3.583 1.087 12.213 13.709 0.000 0.972 3.610 0.000 -5.112 0.000 -7.557 -0.000
F6 SW APARTMENT 0.817 -24.340 0.000 0.000 3.622 1.087 12.213 21.192 0.000 1.533 2.383 0.000 -8.345 0.000 -10.162 -0.000
F6 NW APARTMENT 2.593 -18.553 0.000 0.000 3.703 1.087 12.213 11.909 0.000 1.522 3.031 0.000 -8.288 0.000 -9.218 0.000
F6 SE APARTMENT 0.658 -24.691 0.000 0.000 3.630 1.087 12.213 21.341 0.000 1.532 2.497 0.000 -8.104 0.000 -10.163 -0.000
F6 NE APARTMENT 2.234 -18.896 0.000 0.000 3.717 1.087 12.213 11.854 0.000 1.518 3.236 0.000 -7.809 0.000 -9.154 0.000
F6 N1 APARTMENT 0.702 -15.003 0.000 0.000 3.701 1.087 12.213 4.171 0.000 1.021 4.115 0.000 -5.153 0.000 -6.853 0.000
F6 N2 APARTMENT 0.705 -15.014 0.000 0.000 3.703 1.087 12.213 4.170 0.000 1.021 4.115 0.000 -5.148 0.000 -6.851 0.000
F6 S1 APARTMENT 0.155 -21.648 0.000 0.000 3.592 1.087 12.213 13.627 0.000 1.027 2.907 0.000 -5.100 0.000 -7.860 -0.000
F6 S2 APARTMENT 0.156 -21.657 0.000 0.000 3.593 1.087 12.213 13.625 0.000 1.027 2.917 0.000 -5.098 0.000 -7.862 -0.000
F7 SW APARTMENT 0.968 -23.776 0.000 0.000 3.629 1.087 12.213 21.071 0.000 1.606 2.073 0.000 -8.333 0.000 -10.537 -0.001
F7 NW APARTMENT 2.926 -18.303 0.000 0.000 3.710 1.087 12.213 11.851 0.000 1.595 2.757 0.000 -8.279 0.000 -9.556 -0.000
F7 SE APARTMENT 0.797 -24.120 0.000 0.000 3.638 1.087 12.213 21.226 0.000 1.604 2.185 0.000 -8.091 0.000 -10.538 -0.000
F7 NE APARTMENT 2.550 -18.622 0.000 0.000 3.724 1.087 12.213 11.800 0.000 1.589 2.951 0.000 -7.800 0.000 -9.492 -0.000
F7 N1 APARTMENT 0.843 -14.715 0.000 0.000 3.709 1.087 12.213 4.156 0.000 1.067 3.860 0.000 -5.147 0.000 -7.072 0.000
F7 N2 APARTMENT 0.845 -14.725 0.000 0.000 3.710 1.087 12.213 4.155 0.000 1.067 3.862 0.000 -5.142 0.000 -7.069 0.000
F7 S1 APARTMENT 0.183 -21.097 0.000 0.000 3.600 1.087 12.213 13.550 0.000 1.073 2.600 0.000 -5.093 0.000 -8.115 -0.000
F7 S2 APARTMENT 0.184 -21.107 0.000 0.000 3.600 1.087 12.213 13.548 0.000 1.074 2.610 0.000 -5.091 0.000 -8.117 -0.000
F8 SW APARTMENT 1.135 -23.426 0.000 0.000 3.636 1.087 12.213 20.962 0.000 1.680 1.936 0.000 -8.325 0.000 -10.898 -0.001
F8 NW APARTMENT 3.249 -18.243 0.000 0.000 3.716 1.087 12.213 11.794 0.000 1.668 2.687 0.000 -8.279 0.000 -9.890 -0.000
F8 SE APARTMENT 0.953 -23.766 0.000 0.000 3.644 1.087 12.213 21.121 0.000 1.679 2.053 0.000 -8.083 0.000 -10.900 -0.000
F8 NE APARTMENT 2.857 -18.562 0.000 0.000 3.729 1.087 12.213 11.748 0.000 1.664 2.891 0.000 -7.799 0.000 -9.827 -0.000
F8 N1 APARTMENT 0.992 -14.611 0.000 0.000 3.714 1.087 12.213 4.140 0.000 1.117 3.794 0.000 -5.146 0.000 -7.299 0.000
F8 N2 APARTMENT 0.993 -14.621 0.000 0.000 3.715 1.087 12.213 4.138 0.000 1.116 3.796 0.000 -5.142 0.000 -7.297 0.000
F8 S1 APARTMENT 0.216 -20.735 0.000 0.000 3.607 1.087 12.213 13.481 0.000 1.125 2.461 0.000 -5.087 0.000 -8.367 -0.000
F8 S2 APARTMENT 0.216 -20.744 0.000 0.000 3.607 1.087 12.213 13.480 0.000 1.125 2.472 0.000 -5.085 0.000 -8.369 -0.000
F9 SW APARTMENT 1.482 -23.506 0.000 0.000 3.644 1.087 12.213 20.872 0.000 1.744 1.977 0.000 -8.310 0.000 -11.202 -0.001
F9 NW APARTMENT 3.799 -18.719 0.000 0.000 3.719 1.087 12.213 11.738 0.000 1.731 2.919 0.000 -8.287 0.000 -10.199 -0.000
F9 SE APARTMENT 1.248 -23.821 0.000 0.000 3.653 1.087 12.213 21.032 0.000 1.744 2.122 0.000 -8.068 0.000 -11.208 -0.000
F9 NE APARTMENT 3.347 -18.995 0.000 0.000 3.732 1.087 12.213 11.695 0.000 1.728 3.144 0.000 -7.808 0.000 -10.142 -0.000
F9 N1 APARTMENT 1.265 -14.922 0.000 0.000 3.718 1.087 12.213 4.121 0.000 1.159 4.019 0.000 -5.149 0.000 -7.510 0.000
F9 N2 APARTMENT 1.267 -14.933 0.000 0.000 3.719 1.087 12.213 4.119 0.000 1.159 4.023 0.000 -5.144 0.000 -7.509 0.000
F9 S1 APARTMENT 0.286 -20.674 0.000 0.000 3.617 1.087 12.213 13.426 0.000 1.169 2.519 0.000 -5.074 0.000 -8.568 -0.000
F9 S2 APARTMENT 0.286 -20.687 0.000 0.000 3.618 1.087 12.213 13.424 0.000 1.169 2.534 0.000 -5.072 0.000 -8.571 -0.000
T SW APARTMENT 4.623 -26.045 0.000 0.000 3.686 1.087 12.213 20.459 0.000 1.797 1.479 0.000 -7.868 0.000 -11.429 -0.000
T NW APARTMENT 7.156 -20.933 0.000 0.000 3.729 1.087 12.213 11.354 0.000 1.783 2.213 0.000 -7.963 0.000 -10.638 -0.000
T SE APARTMENT 4.191 -25.958 0.000 0.000 3.693 1.087 12.213 20.636 0.000 1.797 1.445 0.000 -7.653 0.000 -11.449 -0.000
T NE APARTMENT 6.472 -20.834 0.000 0.000 3.743 1.087 12.213 11.370 0.000 1.784 2.306 0.000 -7.546 0.000 -10.594 -0.001
T N1 APARTMENT 3.242 -16.347 0.000 0.000 3.730 1.087 12.213 3.973 0.000 1.195 3.679 0.000 -4.948 0.000 -7.825 -0.000
T N2 APARTMENT 3.254 -16.360 0.000 0.000 3.731 1.087 12.213 3.969 0.000 1.195 3.682 0.000 -4.942 0.000 -7.829 -0.000
T S1 APARTMENT 1.511 -21.973 0.000 0.000 3.666 1.087 12.213 13.208 0.000 1.207 2.626 0.000 -4.831 0.000 -8.713 -0.000
T S2 APARTMENT 1.516 -21.996 0.000 0.000 3.666 1.087 12.213 13.204 0.000 1.207 2.648 0.000 -4.828 0.000 -8.717 -0.000
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 5.528 0.000 5.420 2.622 0.000 -1.759 0.000 -28.252 -0.000
F2 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 2.536 0.000 0.085 0.000 0.000 -1.040 0.000 -0.721 -17.299
F3 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 2.473 0.000 0.097 0.000 0.000 -1.078 0.000 -0.887 -17.045
F4 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 2.434 0.000 0.105 0.000 0.000 -1.095 0.000 -1.005 -16.878
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 32.880 0.000 2.391 0.000 0.098 0.000 0.000 -1.122 0.000 -1.155 -33.092
F6 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 2.395 0.000 0.121 0.000 0.000 -1.099 0.000 -1.162 -16.695
F7 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 2.388 0.000 0.130 0.000 0.000 -1.091 0.000 -1.212 -16.655
F8 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 2.377 0.000 0.135 0.000 0.000 -1.089 0.000 -1.264 -16.598
F9 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 2.365 0.000 0.135 0.000 0.000 -1.091 0.000 -1.313 -16.535
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 8.151 2.273 0.000 0.081 0.000 0.000 -1.064 0.000 -1.428 -24.453
Total Facility 107.258 -1549.618 0.000 0.000 290.516 296.560 982.450 1058.681 0.000 100.403 192.794 0.000 -531.500 0.000 -673.028 -274.524


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 29-SEP-15:15 0.00 -2584.63 0.00 0.00 48.90 45.40 470.89 3487.59 0.00 30.06 0.00 0.00 0.00 0.00 0.00 -1498.22
G NW APARTMENT 09-JUN-17:20 0.00 -2427.13 0.00 0.00 141.81 87.56 588.62 2490.23 0.00 194.91 0.00 0.00 0.00 0.00 0.00 -1075.99
OFFICE 29-SEP-13:30 0.00 -3587.36 0.00 0.00 65.20 2345.88 588.62 2672.12 0.00 46.43 0.00 0.00 0.00 0.00 0.00 -2130.89
G NE APARTMENT 07-JUN-09:45 0.00 -1825.61 0.00 0.00 40.75 12.97 406.15 2039.78 0.00 193.89 0.00 0.00 0.00 0.00 0.00 -867.93
G N1 APARTMENT 09-JUN-17:20 0.00 -1356.06 0.00 0.00 141.81 87.56 588.62 818.89 0.00 117.57 0.00 0.00 0.00 0.00 0.00 -398.39
G N2 APARTMENT 09-JUN-17:20 0.00 -1343.89 0.00 0.00 141.81 87.56 588.62 819.18 0.00 117.57 0.00 0.00 0.00 0.00 0.00 -410.84
G S1 APARTMENT 30-SEP-11:15 0.00 -1567.45 0.00 0.00 40.58 12.97 406.15 2662.21 0.00 41.87 0.00 0.00 0.00 0.00 0.00 -1596.33
G S2 APARTMENT 29-SEP-13:00 0.00 -1624.92 0.00 0.00 39.78 12.97 388.49 2470.71 0.00 21.59 0.00 0.00 0.00 0.00 0.00 -1308.62
F2 SW APARTMENT 29-SEP-15:15 0.00 -3149.28 0.00 0.00 48.90 45.40 470.89 3432.71 0.00 43.22 0.00 0.00 0.00 0.00 0.00 -891.84
F2 NW APARTMENT 09-JUN-17:10 0.00 -2945.39 0.00 0.00 141.81 87.56 588.62 2415.32 0.00 319.67 0.00 0.00 0.00 0.00 0.00 -607.58
F2 SE APARTMENT 01-OCT-13:15 0.00 -2842.13 0.00 0.00 40.75 12.97 382.60 2907.40 0.00 58.29 0.00 0.00 0.00 0.00 0.00 -559.88
F2 NE APARTMENT 07-JUN-09:30 0.00 -2345.54 0.00 0.00 40.75 12.97 406.15 2058.94 0.00 254.29 0.00 0.00 0.00 0.00 0.00 -427.56
F2 N1 APARTMENT 09-JUN-17:20 0.00 -1718.32 0.00 0.00 141.81 87.56 588.62 794.56 0.00 168.57 0.00 0.00 0.00 0.00 0.00 -62.79
F2 N2 APARTMENT 09-JUN-17:20 0.00 -1710.16 0.00 0.00 141.81 87.56 588.62 794.71 0.00 168.57 0.00 0.00 0.00 0.00 0.00 -71.10
F2 S1 APARTMENT 28-OCT-14:30 0.00 -2017.64 0.00 0.00 40.75 22.70 400.26 2214.96 0.00 0.00 0.00 0.00 0.00 0.00 -100.72 -560.30
F2 S2 APARTMENT 28-OCT-14:30 0.00 -2026.89 0.00 0.00 40.75 22.70 400.26 2214.80 0.00 0.00 0.00 0.00 0.00 0.00 -100.62 -550.99
F3 SW APARTMENT 29-SEP-15:30 0.00 -3151.04 0.00 0.00 48.90 45.40 470.89 3270.80 0.00 52.76 0.00 0.00 0.00 0.00 0.00 -737.72
F3 NW APARTMENT 09-JUN-17:30 0.00 -2980.45 0.00 0.00 141.63 87.56 588.62 2366.28 0.00 330.04 0.00 0.00 0.00 0.00 0.00 -533.66
F3 SE APARTMENT 01-OCT-10:30 0.00 -2770.88 0.00 0.00 40.75 12.97 412.03 3433.26 0.00 106.71 0.00 0.00 0.00 0.00 0.00 -1234.85
F3 NE APARTMENT 07-JUN-09:15 0.00 -2379.07 0.00 0.00 40.75 12.97 406.15 2106.16 0.00 273.39 0.00 0.00 0.00 0.00 0.00 -460.36
F3 N1 APARTMENT 09-JUN-17:45 0.00 -1755.10 0.00 0.00 141.54 87.56 588.62 766.70 0.00 171.47 0.00 0.00 0.00 0.00 0.00 -0.79
F3 N2 APARTMENT 09-JUN-17:45 0.00 -1745.94 0.00 0.00 141.51 87.56 588.62 766.82 0.00 171.44 0.00 0.00 0.00 0.00 0.00 -10.01
F3 S1 APARTMENT 28-OCT-14:15 0.00 -2059.54 0.00 0.00 40.72 22.70 400.26 2294.99 0.00 0.00 0.00 0.00 0.00 0.00 -153.66 -545.47
F3 S2 APARTMENT 28-OCT-14:15 0.00 -2066.18 0.00 0.00 40.73 22.70 400.26 2294.98 0.00 0.00 0.00 0.00 0.00 0.00 -153.05 -539.43
F4 SW APARTMENT 22-OCT-15:00 0.00 -3161.66 0.00 0.00 40.75 22.70 400.26 3311.16 0.00 202.85 0.00 0.00 0.00 0.00 0.00 -816.05
F4 NW APARTMENT 09-JUN-17:30 0.00 -2990.05 0.00 0.00 141.44 87.56 588.62 2336.73 0.00 367.32 0.00 0.00 0.00 0.00 0.00 -531.61
F4 SE APARTMENT 01-OCT-10:30 0.00 -2776.90 0.00 0.00 40.75 12.97 412.03 3432.25 0.00 104.79 0.00 0.00 0.00 0.00 0.00 -1225.90
F4 NE APARTMENT 07-JUN-09:15 0.00 -2391.84 0.00 0.00 40.75 12.97 406.15 2086.60 0.00 304.19 0.00 0.00 0.00 0.00 0.00 -458.82
F4 N1 APARTMENT 09-JUN-17:45 0.00 -1773.69 0.00 0.00 141.38 87.56 588.62 760.76 0.00 190.87 4.52 0.00 0.00 0.00 0.00 0.00
F4 N2 APARTMENT 08-JUN-20:30 0.00 -1769.17 0.00 0.00 163.00 71.34 500.33 0.00 0.00 569.08 465.67 0.00 -0.25 0.00 0.00 0.00
F4 S1 APARTMENT 03-NOV-14:30 0.00 -2082.38 0.00 0.00 40.59 22.70 400.26 2338.40 0.00 0.00 0.00 0.00 0.00 0.00 -101.12 -618.45
F4 S2 APARTMENT 03-NOV-14:30 0.00 -2086.57 0.00 0.00 40.60 22.70 400.26 2338.54 0.00 0.00 0.00 0.00 0.00 0.00 -100.30 -615.23
M SW APARTMENT 22-OCT-15:00 0.00 -3184.55 0.00 0.00 40.75 22.70 400.26 3299.56 0.00 204.54 0.00 0.00 0.00 0.00 0.00 -783.26
M NW APARTMENT 09-JUN-17:30 0.00 -3023.18 0.00 0.00 141.33 87.56 588.62 2313.14 0.00 397.80 0.00 0.00 0.00 0.00 0.00 -505.26
M SE APARTMENT 29-SEP-12:00 0.00 -2812.81 0.00 0.00 40.75 12.97 406.15 2481.74 0.00 404.37 0.00 0.00 0.00 0.00 0.00 -533.16
M NE APARTMENT 07-JUN-09:15 0.00 -2426.59 0.00 0.00 40.75 12.97 406.15 2070.64 0.00 329.27 0.00 0.00 0.00 0.00 0.00 -433.18
M N1 APARTMENT 08-JUN-20:30 0.00 -1824.07 0.00 0.00 163.00 71.34 500.33 0.00 0.00 606.22 483.38 0.00 -0.21 0.00 0.00 0.00
M N2 APARTMENT 08-JUN-20:30 0.00 -1816.31 0.00 0.00 163.00 71.34 500.33 0.00 0.00 604.53 477.35 0.00 -0.24 0.00 0.00 0.00
M S1 APARTMENT 03-NOV-14:30 0.00 -2123.22 0.00 0.00 40.66 22.70 400.26 2333.26 0.00 0.00 0.00 0.00 0.00 0.00 -101.95 -571.70
M S2 APARTMENT 03-NOV-14:30 0.00 -2127.04 0.00 0.00 40.68 22.70 400.26 2333.42 0.00 0.00 0.00 0.00 0.00 0.00 -101.07 -568.94
F6 SW APARTMENT 22-OCT-15:00 0.00 -3144.28 0.00 0.00 40.75 22.70 400.26 3291.06 0.00 205.72 0.00 0.00 0.00 0.00 0.00 -816.22
F6 NW APARTMENT 09-JUN-17:20 0.00 -2991.93 0.00 0.00 141.17 87.56 588.62 2295.17 0.00 422.56 0.00 0.00 0.00 0.00 0.00 -543.15
F6 SE APARTMENT 29-SEP-12:00 0.00 -2797.02 0.00 0.00 40.75 12.97 406.15 2460.23 0.00 424.55 0.00 0.00 0.00 0.00 0.00 -547.62
F6 NE APARTMENT 07-JUN-09:15 0.00 -2408.69 0.00 0.00 40.75 12.97 406.15 2059.15 0.00 350.81 0.00 0.00 0.00 0.00 0.00 -461.14
F6 N1 APARTMENT 09-MAY-20:00 0.00 -1809.16 0.00 0.00 141.81 103.77 523.87 0.00 0.00 709.15 343.84 0.00 -13.29 0.00 0.00 0.00
F6 N2 APARTMENT 09-MAY-20:00 0.00 -1804.22 0.00 0.00 141.81 103.77 523.87 0.00 0.00 709.15 338.76 0.00 -13.15 0.00 0.00 0.00
F6 S1 APARTMENT 03-NOV-14:30 0.00 -2097.92 0.00 0.00 40.73 22.70 400.26 2330.06 0.00 0.00 0.00 0.00 0.00 0.00 -102.00 -593.83
F6 S2 APARTMENT 03-NOV-14:30 0.00 -2101.46 0.00 0.00 40.74 22.70 400.26 2330.18 0.00 0.00 0.00 0.00 0.00 0.00 -101.18 -591.24
F7 SW APARTMENT 22-OCT-15:00 0.00 -3124.35 0.00 0.00 40.75 22.70 400.26 3282.90 0.00 206.54 0.00 0.00 0.00 0.00 0.00 -828.80
F7 NW APARTMENT 09-JUN-17:20 0.00 -2984.97 0.00 0.00 141.06 87.56 588.62 2279.35 0.00 444.94 0.00 0.00 0.00 0.00 0.00 -556.56
F7 SE APARTMENT 29-SEP-12:00 0.00 -2802.05 0.00 0.00 40.75 12.97 406.15 2441.10 0.00 442.29 0.00 0.00 0.00 0.00 0.00 -541.21
F7 NE APARTMENT 02-JUL-21:00 0.00 -2411.22 0.00 0.00 163.00 71.34 500.33 314.83 0.00 782.72 579.01 0.00 0.00 0.00 0.00 0.00
F7 N1 APARTMENT 09-MAY-20:00 0.00 -1818.40 0.00 0.00 141.81 103.77 523.87 0.00 0.00 737.30 324.06 0.00 -12.41 0.00 0.00 0.00
F7 N2 APARTMENT 09-MAY-20:00 0.00 -1810.01 0.00 0.00 141.81 103.77 523.87 0.00 0.00 736.49 316.34 0.00 -12.27 0.00 0.00 0.00
F7 S1 APARTMENT 03-NOV-14:30 0.00 -2087.41 0.00 0.00 40.75 22.70 400.26 2326.80 0.00 0.00 0.00 0.00 0.00 0.00 -103.07 -600.03
F7 S2 APARTMENT 03-NOV-14:30 0.00 -2081.74 0.00 0.00 40.75 22.70 400.26 2326.87 0.00 0.00 0.00 0.00 0.00 0.00 -103.07 -605.77
F8 SW APARTMENT 22-OCT-15:00 0.00 -3111.10 0.00 0.00 40.75 22.70 400.26 3275.28 0.00 207.07 0.00 0.00 0.00 0.00 0.00 -834.97
F8 NW APARTMENT 06-JUL-16:30 0.00 -2996.54 0.00 0.00 84.76 64.86 588.62 2512.24 0.00 480.97 0.00 0.00 0.00 0.00 0.00 -734.90
F8 SE APARTMENT 29-SEP-12:00 0.00 -2810.40 0.00 0.00 40.75 12.97 406.15 2423.95 0.00 457.32 0.00 0.00 0.00 0.00 0.00 -530.74
F8 NE APARTMENT 02-JUL-21:00 0.00 -2475.07 0.00 0.00 163.00 71.34 500.33 316.46 0.00 820.62 603.32 0.00 0.00 0.00 0.00 0.00
F8 N1 APARTMENT 08-JUN-20:30 0.00 -1831.39 0.00 0.00 163.00 71.34 500.33 1.39 0.00 679.98 415.35 0.00 0.00 0.00 0.00 0.00
F8 N2 APARTMENT 08-JUN-20:30 0.00 -1823.86 0.00 0.00 163.00 71.34 500.33 1.35 0.00 678.06 409.78 0.00 0.00 0.00 0.00 0.00
F8 S1 APARTMENT 22-OCT-12:30 0.00 -2067.88 0.00 0.00 40.68 12.97 388.49 2533.25 0.00 5.45 0.00 0.00 0.00 0.00 0.00 -912.97
F8 S2 APARTMENT 22-OCT-12:30 0.00 -2072.74 0.00 0.00 40.67 12.97 388.49 2533.09 0.00 5.28 0.00 0.00 0.00 0.00 0.00 -907.75
F9 SW APARTMENT 22-OCT-15:15 0.00 -3219.39 0.00 0.00 48.90 45.40 470.89 3170.29 0.00 232.85 0.00 0.00 0.00 0.00 0.00 -748.93
F9 NW APARTMENT 06-JUL-16:30 0.00 -3121.51 0.00 0.00 84.76 64.86 588.62 2500.42 0.00 500.66 0.00 0.00 0.00 0.00 0.00 -617.81
F9 SE APARTMENT 29-SEP-12:00 0.00 -2835.45 0.00 0.00 40.75 12.97 406.15 2407.66 0.00 469.22 0.00 0.00 0.00 0.00 0.00 -501.29
F9 NE APARTMENT 02-JUL-21:00 0.00 -2597.96 0.00 0.00 163.00 71.34 500.33 313.50 0.00 852.93 696.87 0.00 0.00 0.00 0.00 0.00
F9 N1 APARTMENT 08-JUN-20:30 0.00 -1940.30 0.00 0.00 163.00 71.34 500.33 0.00 0.00 703.97 502.36 0.00 -0.70 0.00 0.00 0.00
F9 N2 APARTMENT 08-JUN-20:30 0.00 -1932.74 0.00 0.00 163.00 71.34 500.33 0.00 0.00 702.13 496.66 0.00 -0.72 0.00 0.00 0.00
F9 S1 APARTMENT 22-OCT-13:00 0.00 -2147.29 0.00 0.00 40.60 12.97 388.49 2531.40 0.00 44.86 0.00 0.00 0.00 0.00 0.00 -871.03
F9 S2 APARTMENT 22-OCT-13:00 0.00 -2151.86 0.00 0.00 40.59 12.97 388.49 2531.21 0.00 44.60 0.00 0.00 0.00 0.00 0.00 -866.00
T SW APARTMENT 01-OCT-14:15 0.00 -4108.09 0.00 0.00 40.62 22.70 400.26 3468.31 0.00 223.46 0.00 0.00 0.00 0.00 0.00 -47.26
T NW APARTMENT 06-JUL-16:30 0.00 -3976.62 0.00 0.00 84.76 64.86 588.62 2444.33 0.00 519.16 274.90 0.00 0.00 0.00 0.00 0.00
T SE APARTMENT 01-OCT-12:15 0.00 -3710.11 0.00 0.00 40.75 12.97 388.49 2894.22 0.00 115.71 257.98 0.00 0.00 0.00 0.00 0.00
T NE APARTMENT 05-JUN-17:00 0.00 -3283.69 0.00 0.00 83.17 64.86 588.62 1142.88 0.00 951.25 452.91 0.00 0.00 0.00 0.00 0.00
T N1 APARTMENT 17-JUN-18:00 0.00 -2560.76 0.00 0.00 141.36 87.56 588.62 782.89 0.00 308.70 651.64 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 17-JUN-18:00 0.00 -2554.45 0.00 0.00 141.66 87.56 588.62 784.06 0.00 309.68 642.87 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 22-OCT-13:15 0.00 -3060.08 0.00 0.00 40.63 12.97 382.60 2451.77 0.00 70.00 102.11 0.00 0.00 0.00 0.00 0.00
T S2 APARTMENT 22-OCT-13:15 0.00 -3064.00 0.00 0.00 40.63 12.97 382.60 2451.62 0.00 69.84 106.34 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 05-JUN-17:00 0.00 -180704.53 0.00 0.00 6570.07 11327.17 47312.53 99215.70 0.00 53858.61 0.00 0.00 0.00 0.00 0.00 -37579.55


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 06-APR-14:00 1693.54 0.00 0.00 0.00 42.50 12.97 382.60 1415.01 0.00 0.00 0.00 0.00 0.00 0.00 -2202.03 -1344.59
G NW APARTMENT 06-APR-14:00 1525.64 0.00 0.00 0.00 43.96 12.97 382.60 963.67 0.00 0.00 0.00 0.00 0.00 0.00 -2198.59 -730.26
OFFICE 09-FEB-01:00 798.27 0.00 0.00 0.00 0.00 469.18 194.24 0.00 0.00 0.00 452.24 0.00 -986.75 0.00 -927.18 0.00
G NE APARTMENT 11-MAR-15:55 1628.54 0.00 0.00 0.00 45.65 22.70 400.26 183.10 0.00 0.00 0.00 0.00 0.00 0.00 -1535.34 -744.91
G N1 APARTMENT 06-APR-13:55 1648.79 0.00 0.00 0.00 44.29 12.97 382.60 271.56 0.00 0.00 0.00 0.00 0.00 0.00 -2057.94 -302.27
G N2 APARTMENT 06-APR-13:55 1622.47 0.00 0.00 0.00 44.24 12.97 382.60 271.02 0.00 0.00 0.00 0.00 0.00 0.00 -2058.62 -274.69
G S1 APARTMENT 06-APR-14:00 1708.26 0.00 0.00 0.00 42.62 12.97 382.60 730.81 0.00 0.00 0.00 0.00 0.00 0.00 -2038.53 -838.73
G S2 APARTMENT 06-APR-14:00 1768.22 0.00 0.00 0.00 42.19 12.97 382.60 726.19 0.00 0.00 0.00 0.00 0.00 0.00 -2039.21 -892.97
F2 SW APARTMENT 06-APR-14:00 1253.87 0.00 0.00 0.00 40.83 12.97 382.60 1216.21 0.00 0.00 142.53 0.00 0.00 0.00 -3049.02 0.00
F2 NW APARTMENT 06-APR-14:00 1733.60 0.00 0.00 0.00 42.10 12.97 382.60 817.40 0.00 0.00 42.81 0.00 0.00 0.00 -3031.48 0.00
F2 SE APARTMENT 26-JAN-00:30 808.76 0.00 0.00 0.00 189.67 6.49 264.88 0.00 0.00 0.00 526.92 0.00 -769.41 0.00 -1027.31 0.00
F2 NE APARTMENT 06-APR-14:00 1690.67 0.00 0.00 0.00 41.90 12.97 382.60 332.11 0.00 0.00 568.87 0.00 0.00 0.00 -3029.12 0.00
F2 N1 APARTMENT 06-APR-14:00 1829.13 0.00 0.00 0.00 41.91 12.97 382.60 207.96 0.00 0.00 322.62 0.00 0.00 0.00 -2797.19 0.00
F2 N2 APARTMENT 06-APR-14:00 1830.85 0.00 0.00 0.00 41.86 12.97 382.60 207.28 0.00 0.00 321.66 0.00 0.00 0.00 -2797.22 0.00
F2 S1 APARTMENT 06-APR-14:00 1672.51 0.00 0.00 0.00 40.75 12.97 382.60 617.41 0.00 0.00 75.50 0.00 0.00 0.00 -2801.75 0.00
F2 S2 APARTMENT 06-APR-14:00 1538.79 0.00 0.00 0.00 40.75 12.97 382.60 616.54 0.00 0.00 212.22 0.00 0.00 0.00 -2803.87 0.00
F3 SW APARTMENT 06-APR-14:00 1830.31 0.00 0.00 0.00 41.00 12.97 382.60 1146.55 0.00 0.00 140.35 0.00 0.00 0.00 -3553.80 0.00
F3 NW APARTMENT 06-APR-14:00 1875.94 0.00 0.00 0.00 42.13 12.97 382.60 768.26 0.00 0.00 468.88 0.00 0.00 0.00 -3550.79 0.00
F3 SE APARTMENT 06-APR-14:00 1778.09 0.00 0.00 0.00 40.75 12.97 382.60 682.87 0.00 0.00 654.53 0.00 0.00 0.00 -3551.81 0.00
F3 NE APARTMENT 06-APR-14:00 1826.70 0.00 0.00 0.00 41.92 12.97 382.60 304.69 0.00 0.00 979.86 0.00 0.00 0.00 -3548.75 0.00
F3 N1 APARTMENT 06-APR-14:00 1962.07 0.00 0.00 0.00 41.63 12.97 382.60 188.78 0.00 0.00 686.21 0.00 0.00 0.00 -3274.27 0.00
F3 N2 APARTMENT 06-APR-14:00 1962.20 0.00 0.00 0.00 41.58 12.97 382.60 188.12 0.00 0.00 686.83 0.00 0.00 0.00 -3274.29 0.00
F3 S1 APARTMENT 06-APR-14:00 1884.03 0.00 0.00 0.00 40.75 12.97 382.60 577.60 0.00 0.00 377.48 0.00 0.00 0.00 -3275.44 0.00
F3 S2 APARTMENT 06-APR-14:00 1865.35 0.00 0.00 0.00 40.75 12.97 382.60 577.13 0.00 0.00 396.67 0.00 0.00 0.00 -3275.48 0.00
F4 SW APARTMENT 06-APR-14:15 1737.85 0.00 0.00 0.00 41.40 22.70 400.26 1176.48 0.00 0.00 221.17 0.00 0.00 0.00 -3599.86 0.00
F4 NW APARTMENT 06-APR-14:15 1794.58 0.00 0.00 0.00 42.43 22.70 400.26 826.40 0.00 0.00 510.72 0.00 0.00 0.00 -3597.08 0.00
F4 SE APARTMENT 06-APR-14:15 1702.72 0.00 0.00 0.00 41.27 22.70 400.26 621.59 0.00 0.00 809.16 0.00 0.00 0.00 -3597.69 0.00
F4 NE APARTMENT 06-APR-14:15 1741.09 0.00 0.00 0.00 42.38 22.70 400.26 271.57 0.00 0.00 1116.88 0.00 0.00 0.00 -3594.88 0.00
F4 N1 APARTMENT 06-APR-14:15 1892.82 0.00 0.00 0.00 41.87 22.70 400.26 167.01 0.00 0.00 791.84 0.00 0.00 0.00 -3316.49 0.00
F4 N2 APARTMENT 06-APR-14:15 1892.25 0.00 0.00 0.00 41.82 22.70 400.26 166.40 0.00 0.00 793.09 0.00 0.00 0.00 -3316.51 0.00
F4 S1 APARTMENT 06-APR-14:15 1905.24 0.00 0.00 0.00 40.75 22.70 400.26 525.49 0.00 0.00 423.42 0.00 0.00 0.00 -3317.85 0.00
F4 S2 APARTMENT 06-APR-14:15 1887.93 0.00 0.00 0.00 40.75 22.70 400.26 525.08 0.00 0.00 441.16 0.00 0.00 0.00 -3317.88 0.00
M SW APARTMENT 06-APR-14:15 1852.46 0.00 0.00 0.00 41.75 22.70 400.26 1148.37 0.00 0.00 438.45 0.00 0.00 0.00 -3904.00 0.00
M NW APARTMENT 06-APR-14:10 2014.86 0.00 0.00 0.00 42.72 22.70 400.26 807.26 0.00 0.00 667.35 0.00 0.00 0.00 -3955.15 0.00
M SE APARTMENT 06-APR-14:15 1813.81 0.00 0.00 0.00 41.62 22.70 400.26 604.56 0.00 0.00 1019.18 0.00 0.00 0.00 -3902.13 0.00
M NE APARTMENT 06-APR-14:10 1984.04 0.00 0.00 0.00 42.66 22.70 400.26 263.36 0.00 0.00 1232.31 0.00 0.00 0.00 -3945.34 0.00
M N1 APARTMENT 06-APR-14:15 1990.36 0.00 0.00 0.00 42.03 22.70 400.26 161.10 0.00 0.00 980.10 0.00 0.00 0.00 -3596.54 0.00
M N2 APARTMENT 06-APR-14:15 1989.21 0.00 0.00 0.00 41.98 22.70 400.26 160.50 0.00 0.00 981.91 0.00 0.00 0.00 -3596.56 0.00
M S1 APARTMENT 06-APR-14:15 1995.32 0.00 0.00 0.00 40.94 22.70 400.26 510.13 0.00 0.00 628.52 0.00 0.00 0.00 -3597.87 0.00
M S2 APARTMENT 06-APR-14:15 1995.97 0.00 0.00 0.00 40.88 22.70 400.26 509.45 0.00 0.00 628.68 0.00 0.00 0.00 -3597.95 0.00
F6 SW APARTMENT 06-APR-14:10 1986.08 0.00 0.00 0.00 42.27 22.70 400.26 1131.54 0.00 0.00 648.56 0.00 0.00 0.00 -4231.41 0.00
F6 NW APARTMENT 06-APR-14:10 2660.87 0.00 0.00 0.00 43.19 22.70 400.26 796.78 0.00 0.00 281.48 0.00 0.00 0.00 -4205.27 0.00
F6 SE APARTMENT 10-APR-17:00 1995.29 0.00 0.00 0.00 98.63 64.86 588.62 0.00 0.00 0.00 1966.99 0.00 -144.10 0.00 -4570.29 0.00
F6 NE APARTMENT 06-APR-14:10 2647.50 0.00 0.00 0.00 43.13 22.70 400.26 261.33 0.00 0.00 822.73 0.00 0.00 0.00 -4197.65 0.00
F6 N1 APARTMENT 06-APR-14:10 2563.80 0.00 0.00 0.00 42.42 22.70 400.26 159.27 0.00 0.00 686.16 0.00 0.00 0.00 -3874.61 0.00
F6 N2 APARTMENT 06-APR-14:10 2533.53 0.00 0.00 0.00 42.37 22.70 400.26 158.69 0.00 0.00 717.69 0.00 0.00 0.00 -3875.24 0.00
F6 S1 APARTMENT 06-APR-14:15 2072.67 0.00 0.00 0.00 41.38 22.70 400.26 501.57 0.00 0.00 803.90 0.00 0.00 0.00 -3842.48 0.00
F6 S2 APARTMENT 06-APR-14:15 2073.22 0.00 0.00 0.00 41.33 22.70 400.26 500.90 0.00 0.00 804.15 0.00 0.00 0.00 -3842.56 0.00
F7 SW APARTMENT 06-APR-14:10 2533.32 0.00 0.00 0.00 42.64 22.70 400.26 1116.72 0.00 0.00 342.08 0.00 0.00 0.00 -4457.71 0.00
F7 NW APARTMENT 06-APR-14:10 3188.09 0.00 0.00 0.00 43.52 22.70 400.26 787.17 0.00 0.00 0.00 0.00 0.00 0.00 -4432.17 -9.57
F7 SE APARTMENT 06-APR-14:10 2471.08 0.00 0.00 0.00 42.51 22.70 400.26 588.10 0.00 0.00 928.07 0.00 0.00 0.00 -4452.73 0.00
F7 NE APARTMENT 06-APR-14:10 3186.97 0.00 0.00 0.00 43.47 22.70 400.26 258.56 0.00 0.00 514.39 0.00 0.00 0.00 -4426.35 0.00
F7 N1 APARTMENT 06-APR-14:10 3056.41 0.00 0.00 0.00 42.69 22.70 400.26 157.06 0.00 0.00 408.21 0.00 0.00 0.00 -4087.32 0.00
F7 N2 APARTMENT 06-APR-14:10 3027.00 0.00 0.00 0.00 42.64 22.70 400.26 156.49 0.00 0.00 438.88 0.00 0.00 0.00 -4087.96 0.00
F7 S1 APARTMENT 06-APR-14:10 2369.79 0.00 0.00 0.00 41.69 22.70 400.26 493.86 0.00 0.00 777.90 0.00 0.00 0.00 -4106.21 0.00
F7 S2 APARTMENT 06-APR-14:10 2336.48 0.00 0.00 0.00 41.64 22.70 400.26 493.20 0.00 0.00 812.95 0.00 0.00 0.00 -4107.23 0.00
F8 SW APARTMENT 06-APR-14:10 3010.50 0.00 0.00 0.00 42.95 22.70 400.26 1103.98 0.00 0.00 85.32 0.00 0.00 0.00 -4665.71 0.00
F8 NW APARTMENT 06-APR-14:10 3648.38 0.00 0.00 0.00 43.80 22.70 400.26 778.79 0.00 0.00 0.00 0.00 0.00 0.00 -4640.53 -253.40
F8 SE APARTMENT 06-APR-14:10 2954.17 0.00 0.00 0.00 42.81 22.70 400.26 581.00 0.00 0.00 661.10 0.00 0.00 0.00 -4662.05 0.00
F8 NE APARTMENT 06-APR-14:10 3653.37 0.00 0.00 0.00 43.74 22.70 400.26 255.80 0.00 0.00 260.59 0.00 0.00 0.00 -4636.47 0.00
F8 N1 APARTMENT 06-APR-14:10 3483.56 0.00 0.00 0.00 42.90 22.70 400.26 154.91 0.00 0.00 178.46 0.00 0.00 0.00 -4282.79 0.00
F8 N2 APARTMENT 06-APR-14:10 3454.53 0.00 0.00 0.00 42.86 22.70 400.26 154.34 0.00 0.00 208.78 0.00 0.00 0.00 -4283.46 0.00
F8 S1 APARTMENT 06-APR-14:10 2815.53 0.00 0.00 0.00 41.93 22.70 400.26 487.13 0.00 0.00 533.68 0.00 0.00 0.00 -4301.24 0.00
F8 S2 APARTMENT 06-APR-14:10 2782.53 0.00 0.00 0.00 41.88 22.70 400.26 486.47 0.00 0.00 568.40 0.00 0.00 0.00 -4302.25 0.00
F9 SW APARTMENT 06-APR-14:10 3472.26 0.00 0.00 0.00 43.25 22.70 400.26 1094.35 0.00 0.00 0.00 0.00 0.00 0.00 -4859.03 -173.78
F9 NW APARTMENT 06-APR-14:10 3956.90 0.00 0.00 0.00 44.08 22.70 400.26 773.31 0.00 0.00 0.00 0.00 0.00 0.00 -4838.51 -358.74
F9 SE APARTMENT 06-APR-14:10 3403.37 0.00 0.00 0.00 43.09 22.70 400.26 575.50 0.00 0.00 412.11 0.00 0.00 0.00 -4857.03 0.00
F9 NE APARTMENT 06-APR-14:10 3971.54 0.00 0.00 0.00 44.00 22.70 400.26 254.44 0.00 0.00 142.18 0.00 0.00 0.00 -4835.12 0.00
F9 N1 APARTMENT 06-APR-14:10 3906.04 0.00 0.00 0.00 43.12 22.70 400.26 153.90 0.00 0.00 0.00 0.00 0.00 0.00 -4464.24 -61.78
F9 N2 APARTMENT 06-APR-14:10 3873.84 0.00 0.00 0.00 43.07 22.70 400.26 153.26 0.00 0.00 0.00 0.00 0.00 0.00 -4465.07 -28.06
F9 S1 APARTMENT 06-APR-14:10 3243.70 0.00 0.00 0.00 42.17 22.70 400.26 481.94 0.00 0.00 292.18 0.00 0.00 0.00 -4482.95 0.00
F9 S2 APARTMENT 06-APR-14:10 3207.26 0.00 0.00 0.00 42.11 22.70 400.26 481.20 0.00 0.00 330.53 0.00 0.00 0.00 -4484.07 0.00
T SW APARTMENT 10-APR-16:53 3664.08 0.00 0.00 0.00 98.63 64.86 588.62 141.99 0.00 0.00 967.31 0.00 0.00 0.00 -5525.49 0.00
T NW APARTMENT 06-APR-14:25 3902.34 0.00 0.00 0.00 44.12 22.70 400.26 846.89 0.00 0.00 0.00 0.00 0.00 0.00 -4546.99 -669.33
T SE APARTMENT 10-APR-16:53 3764.62 0.00 0.00 0.00 98.63 64.86 588.62 0.00 0.00 0.00 1142.32 0.00 -133.55 0.00 -5525.49 0.00
T NE APARTMENT 06-APR-14:25 3929.85 0.00 0.00 0.00 44.51 22.70 400.26 238.41 0.00 0.00 0.00 0.00 0.00 0.00 -4541.22 -94.52
T N1 APARTMENT 06-APR-14:25 3921.70 0.00 0.00 0.00 43.27 22.70 400.26 142.08 0.00 0.00 0.00 0.00 0.00 0.00 -4195.52 -334.49
T N2 APARTMENT 06-APR-14:25 3896.28 0.00 0.00 0.00 43.23 22.70 400.26 141.45 0.00 0.00 0.00 0.00 0.00 0.00 -4196.61 -307.31
T S1 APARTMENT 10-APR-16:53 3369.18 0.00 0.00 0.00 98.63 64.86 588.62 0.00 0.00 0.00 1043.50 0.00 -85.20 0.00 -5079.59 0.00
T S2 APARTMENT 10-APR-16:53 3371.23 0.00 0.00 0.00 98.63 64.86 588.62 0.00 0.00 0.00 1041.40 0.00 -85.14 0.00 -5079.59 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 10-APR-17:00 145375.50 0.00 0.00 0.00 7787.67 11327.17 47312.53 3507.54 0.00 0.00 119381.12 0.00 -6016.70 0.00 -328674.84 0.00



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Sec1.1A-General Information

Data
Weather File El Paso International Ap Ut TX USA TMY3 WMO#=722700
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 7836.48
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.50
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
F2 SW APARTMENT 88.25 88.25 0.00 168.00
F2 NW APARTMENT 88.25 88.25 0.00 168.00
F2 SE APARTMENT 88.25 88.25 0.00 168.00
F2 NE APARTMENT 88.25 88.25 0.00 168.00
F2 N1 APARTMENT 88.25 88.25 0.00 168.00
F2 N2 APARTMENT 88.25 88.25 0.00 168.00
F2 S1 APARTMENT 88.25 88.25 0.00 168.00
F2 S2 APARTMENT 88.25 88.25 0.00 168.00
F3 SW APARTMENT 88.25 88.25 0.00 168.00
F3 NW APARTMENT 88.25 88.25 0.00 168.00
F3 SE APARTMENT 88.25 88.25 0.00 168.00
F3 NE APARTMENT 88.25 88.25 0.00 168.00
F3 N1 APARTMENT 88.25 88.25 0.00 168.00
F3 N2 APARTMENT 88.25 88.25 0.00 168.00
F3 S1 APARTMENT 88.25 88.25 0.00 168.00
F3 S2 APARTMENT 88.25 88.25 0.00 168.00
F4 SW APARTMENT 88.25 88.25 0.00 168.00
F4 NW APARTMENT 88.25 88.25 0.00 168.00
F4 SE APARTMENT 88.25 88.25 0.00 168.00
F4 NE APARTMENT 88.25 88.25 0.00 168.00
F4 N1 APARTMENT 88.25 88.25 0.00 168.00
F4 N2 APARTMENT 88.25 88.25 0.00 168.00
F4 S1 APARTMENT 88.25 88.25 0.00 168.00
F4 S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
F6 SW APARTMENT 88.25 88.25 0.00 168.00
F6 NW APARTMENT 88.25 88.25 0.00 168.00
F6 SE APARTMENT 88.25 88.25 0.00 168.00
F6 NE APARTMENT 88.25 88.25 0.00 168.00
F6 N1 APARTMENT 88.25 88.25 0.00 168.00
F6 N2 APARTMENT 88.25 88.25 0.00 168.00
F6 S1 APARTMENT 88.25 88.25 0.00 168.00
F6 S2 APARTMENT 88.25 88.25 0.00 168.00
F7 SW APARTMENT 88.25 88.25 0.00 168.00
F7 NW APARTMENT 88.25 88.25 0.00 168.00
F7 SE APARTMENT 88.25 88.25 0.00 168.00
F7 NE APARTMENT 88.25 88.25 0.00 168.00
F7 N1 APARTMENT 88.25 88.25 0.00 168.00
F7 N2 APARTMENT 88.25 88.25 0.00 168.00
F7 S1 APARTMENT 88.25 88.25 0.00 168.00
F7 S2 APARTMENT 88.25 88.25 0.00 168.00
F8 SW APARTMENT 88.25 88.25 0.00 168.00
F8 NW APARTMENT 88.25 88.25 0.00 168.00
F8 SE APARTMENT 88.25 88.25 0.00 168.00
F8 NE APARTMENT 88.25 88.25 0.00 168.00
F8 N1 APARTMENT 88.25 88.25 0.00 168.00
F8 N2 APARTMENT 88.25 88.25 0.00 168.00
F8 S1 APARTMENT 88.25 88.25 0.00 168.00
F8 S2 APARTMENT 88.25 88.25 0.00 168.00
F9 SW APARTMENT 88.25 88.25 0.00 168.00
F9 NW APARTMENT 88.25 88.25 0.00 168.00
F9 SE APARTMENT 88.25 88.25 0.00 168.00
F9 NE APARTMENT 88.25 88.25 0.00 168.00
F9 N1 APARTMENT 88.25 88.25 0.00 168.00
F9 N2 APARTMENT 88.25 88.25 0.00 168.00
F9 S1 APARTMENT 88.25 88.25 0.00 168.00
F9 S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
G CORRIDOR 77.66 0.00 77.66 0.00
F2 CORRIDOR 77.66 0.00 77.66 0.00
F3 CORRIDOR 77.66 0.00 77.66 0.00
F4 CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
F6 CORRIDOR 77.66 0.00 77.66 0.00
F7 CORRIDOR 77.66 0.00 77.66 0.00
F8 CORRIDOR 77.66 0.00 77.66 0.00
F9 CORRIDOR 77.66 0.00 77.66 0.00
T CORRIDOR 77.66 0.00 77.66 0.00
Totals 7836.48 7059.89 776.58  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 65.00
Number of hours cooling loads not met 245.00
Number of hours not met 310.00


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 296.56 14401.37 0.00 0.00 0.00 0.00
Exterior Lighting 162.97 10364.00 0.00 0.00 0.00 0.00
Space Heating 30.37 0.00 61.66 82687.13 0.00 0.00
Space Cooling 636.60 63390.96 0.00 0.00 0.00 0.00
Pumps 56.84 1833.52 0.00 0.00 0.00 0.00
Heat Rejection 24.02 2346.06 0.00 0.00 0.00 0.00
Fans-Interior 695.01 22038.65 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 0.00 0.00 974.83 76170.72 0.00 0.00
Receptacle Equipment 1137.32 49889.93 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 3075.86   1036.49   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 1137.32 3075.86
Natural Gas 0.00 1036.49
Additional 0.00 0.00
Total 1137.32 4112.35


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 37.84
Space Heating 3.88
Space Cooling 81.24
Fans-Interior 88.69
Service Water Heating 0.00
Receptacle Equipment 145.13
Miscellaneous 35.73
Subtotal 392.50


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 7.87
Service Water Heating 124.40
Miscellaneous -0.00
Subtotal 132.26


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 7.21
Space Heating 2.24
Space Cooling 15.48
Fans-Interior 16.90
Service Water Heating 23.70
Receptacle Equipment 27.66
Miscellaneous 6.81



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.244365
G NW APARTMENT DIRECT AIR 0.241788
OFFICE DIRECT AIR 0.358063
G NE APARTMENT DIRECT AIR 0.186792
G N1 APARTMENT DIRECT AIR 0.137045
G N2 APARTMENT DIRECT AIR 0.135840
G S1 APARTMENT DIRECT AIR 0.138200
G S2 APARTMENT DIRECT AIR 0.144687
F2 SW APARTMENT DIRECT AIR 0.300885
F2 NW APARTMENT DIRECT AIR 0.296853
F2 SE APARTMENT DIRECT AIR 0.278016
F2 NE APARTMENT DIRECT AIR 0.235682
F2 N1 APARTMENT DIRECT AIR 0.172003
F2 N2 APARTMENT DIRECT AIR 0.171029
F2 S1 APARTMENT DIRECT AIR 0.175253
F2 S2 APARTMENT DIRECT AIR 0.177274
F3 SW APARTMENT DIRECT AIR 0.302868
F3 NW APARTMENT DIRECT AIR 0.299210
F3 SE APARTMENT DIRECT AIR 0.258984
F3 NE APARTMENT DIRECT AIR 0.239366
F3 N1 APARTMENT DIRECT AIR 0.175073
F3 N2 APARTMENT DIRECT AIR 0.174115
F3 S1 APARTMENT DIRECT AIR 0.178665
F3 S2 APARTMENT DIRECT AIR 0.179367
F4 SW APARTMENT DIRECT AIR 0.305293
F4 NW APARTMENT DIRECT AIR 0.301585
F4 SE APARTMENT DIRECT AIR 0.259986
F4 NE APARTMENT DIRECT AIR 0.241660
F4 N1 APARTMENT DIRECT AIR 0.177395
F4 N2 APARTMENT DIRECT AIR 0.176449
F4 S1 APARTMENT DIRECT AIR 0.181006
F4 S2 APARTMENT DIRECT AIR 0.181513
M SW APARTMENT DIRECT AIR 0.309726
M NW APARTMENT DIRECT AIR 0.306020
M SE APARTMENT DIRECT AIR 0.264811
M NE APARTMENT DIRECT AIR 0.245977
M N1 APARTMENT DIRECT AIR 0.181630
M N2 APARTMENT DIRECT AIR 0.180694
M S1 APARTMENT DIRECT AIR 0.185193
M S2 APARTMENT DIRECT AIR 0.185673
F6 SW APARTMENT DIRECT AIR 0.307669
F6 NW APARTMENT DIRECT AIR 0.303807
F6 SE APARTMENT DIRECT AIR 0.263385
F6 NE APARTMENT DIRECT AIR 0.243878
F6 N1 APARTMENT DIRECT AIR 0.179498
F6 N2 APARTMENT DIRECT AIR 0.178576
F6 S1 APARTMENT DIRECT AIR 0.183135
F6 S2 APARTMENT DIRECT AIR 0.183612
F7 SW APARTMENT DIRECT AIR 0.307801
F7 NW APARTMENT DIRECT AIR 0.303895
F7 SE APARTMENT DIRECT AIR 0.264060
F7 NE APARTMENT DIRECT AIR 0.244039
F7 N1 APARTMENT DIRECT AIR 0.179560
F7 N2 APARTMENT DIRECT AIR 0.178647
F7 S1 APARTMENT DIRECT AIR 0.183193
F7 S2 APARTMENT DIRECT AIR 0.183670
F8 SW APARTMENT DIRECT AIR 0.309410
F8 NW APARTMENT DIRECT AIR 0.305470
F8 SE APARTMENT DIRECT AIR 0.266078
F8 NE APARTMENT DIRECT AIR 0.246051
F8 N1 APARTMENT DIRECT AIR 0.181098
F8 N2 APARTMENT DIRECT AIR 0.180196
F8 S1 APARTMENT DIRECT AIR 0.184681
F8 S2 APARTMENT DIRECT AIR 0.185136
F9 SW APARTMENT DIRECT AIR 0.321616
F9 NW APARTMENT DIRECT AIR 0.317888
F9 SE APARTMENT DIRECT AIR 0.276457
F9 NE APARTMENT DIRECT AIR 0.257370
F9 N1 APARTMENT DIRECT AIR 0.192278
F9 N2 APARTMENT DIRECT AIR 0.191377
F9 S1 APARTMENT DIRECT AIR 0.193501
F9 S2 APARTMENT DIRECT AIR 0.193942
T SW APARTMENT DIRECT AIR 0.411338
T NW APARTMENT DIRECT AIR 0.400966
T SE APARTMENT DIRECT AIR 0.363921
T NE APARTMENT DIRECT AIR 0.339353
T N1 APARTMENT DIRECT AIR 0.261372
T N2 APARTMENT DIRECT AIR 0.261071
T S1 APARTMENT DIRECT AIR 0.284844
T S2 APARTMENT DIRECT AIR 0.285223


Branch

Maximum Flow Rate [m3/s]
AIRLOOP G SW MAIN BRANCH 0.244365
AIRLOOP G NW MAIN BRANCH 0.241788
AIRLOOP OFFICE MAIN BRANCH 0.358063
AIRLOOP G NE MAIN BRANCH 0.186792
AIRLOOP G N1 MAIN BRANCH 0.137045
AIRLOOP G N2 MAIN BRANCH 0.135840
AIRLOOP G S1 MAIN BRANCH 0.138200
AIRLOOP G S2 MAIN BRANCH 0.144687
AIRLOOP F2 SW MAIN BRANCH 0.300885
AIRLOOP F2 NW MAIN BRANCH 0.296853
AIRLOOP F2 SE MAIN BRANCH 0.278016
AIRLOOP F2 NE MAIN BRANCH 0.235682
AIRLOOP F2 N1 MAIN BRANCH 0.172003
AIRLOOP F2 N2 MAIN BRANCH 0.171029
AIRLOOP F2 S1 MAIN BRANCH 0.175253
AIRLOOP F2 S2 MAIN BRANCH 0.177274
AIRLOOP F3 SW MAIN BRANCH 0.302868
AIRLOOP F3 NW MAIN BRANCH 0.299210
AIRLOOP F3 SE MAIN BRANCH 0.258984
AIRLOOP F3 NE MAIN BRANCH 0.239366
AIRLOOP F3 N1 MAIN BRANCH 0.175073
AIRLOOP F3 N2 MAIN BRANCH 0.174115
AIRLOOP F3 S1 MAIN BRANCH 0.178665
AIRLOOP F3 S2 MAIN BRANCH 0.179367
AIRLOOP F4 SW MAIN BRANCH 0.305293
AIRLOOP F4 NW MAIN BRANCH 0.301585
AIRLOOP F4 SE MAIN BRANCH 0.259986
AIRLOOP F4 NE MAIN BRANCH 0.241660
AIRLOOP F4 N1 MAIN BRANCH 0.177395
AIRLOOP F4 N2 MAIN BRANCH 0.176449
AIRLOOP F4 S1 MAIN BRANCH 0.181006
AIRLOOP F4 S2 MAIN BRANCH 0.181513
AIRLOOP M SW MAIN BRANCH 0.309726
AIRLOOP M NW MAIN BRANCH 0.306020
AIRLOOP M SE MAIN BRANCH 0.264811
AIRLOOP M NE MAIN BRANCH 0.245977
AIRLOOP M N1 MAIN BRANCH 0.181630
AIRLOOP M N2 MAIN BRANCH 0.180694
AIRLOOP M S1 MAIN BRANCH 0.185193
AIRLOOP M S2 MAIN BRANCH 0.185673
AIRLOOP F6 SW MAIN BRANCH 0.307669
AIRLOOP F6 NW MAIN BRANCH 0.303807
AIRLOOP F6 SE MAIN BRANCH 0.263385
AIRLOOP F6 NE MAIN BRANCH 0.243878
AIRLOOP F6 N1 MAIN BRANCH 0.179498
AIRLOOP F6 N2 MAIN BRANCH 0.178576
AIRLOOP F6 S1 MAIN BRANCH 0.183135
AIRLOOP F6 S2 MAIN BRANCH 0.183612
AIRLOOP F7 SW MAIN BRANCH 0.307801
AIRLOOP F7 NW MAIN BRANCH 0.303895
AIRLOOP F7 SE MAIN BRANCH 0.264060
AIRLOOP F7 NE MAIN BRANCH 0.244039
AIRLOOP F7 N1 MAIN BRANCH 0.179560
AIRLOOP F7 N2 MAIN BRANCH 0.178647
AIRLOOP F7 S1 MAIN BRANCH 0.183193
AIRLOOP F7 S2 MAIN BRANCH 0.183670
AIRLOOP F8 SW MAIN BRANCH 0.309410
AIRLOOP F8 NW MAIN BRANCH 0.305470
AIRLOOP F8 SE MAIN BRANCH 0.266078
AIRLOOP F8 NE MAIN BRANCH 0.246051
AIRLOOP F8 N1 MAIN BRANCH 0.181098
AIRLOOP F8 N2 MAIN BRANCH 0.180196
AIRLOOP F8 S1 MAIN BRANCH 0.184681
AIRLOOP F8 S2 MAIN BRANCH 0.185136
AIRLOOP F9 SW MAIN BRANCH 0.321616
AIRLOOP F9 NW MAIN BRANCH 0.317888
AIRLOOP F9 SE MAIN BRANCH 0.276457
AIRLOOP F9 NE MAIN BRANCH 0.257370
AIRLOOP F9 N1 MAIN BRANCH 0.192278
AIRLOOP F9 N2 MAIN BRANCH 0.191377
AIRLOOP F9 S1 MAIN BRANCH 0.193501
AIRLOOP F9 S2 MAIN BRANCH 0.193942
AIRLOOP T SW MAIN BRANCH 0.411338
AIRLOOP T NW MAIN BRANCH 0.400966
AIRLOOP T SE MAIN BRANCH 0.363921
AIRLOOP T NE MAIN BRANCH 0.339353
AIRLOOP T N1 MAIN BRANCH 0.261372
AIRLOOP T N2 MAIN BRANCH 0.261071
AIRLOOP T S1 MAIN BRANCH 0.284844
AIRLOOP T S2 MAIN BRANCH 0.285223


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
AIRLOOP G SW 0.244365
AIRLOOP G NW 0.241788
AIRLOOP OFFICE 0.358063
AIRLOOP G NE 0.186792
AIRLOOP G N1 0.137045
AIRLOOP G N2 0.135840
AIRLOOP G S1 0.138200
AIRLOOP G S2 0.144687
AIRLOOP F2 SW 0.300885
AIRLOOP F2 NW 0.296853
AIRLOOP F2 SE 0.278016
AIRLOOP F2 NE 0.235682
AIRLOOP F2 N1 0.172003
AIRLOOP F2 N2 0.171029
AIRLOOP F2 S1 0.175253
AIRLOOP F2 S2 0.177274
AIRLOOP F3 SW 0.302868
AIRLOOP F3 NW 0.299210
AIRLOOP F3 SE 0.258984
AIRLOOP F3 NE 0.239366
AIRLOOP F3 N1 0.175073
AIRLOOP F3 N2 0.174115
AIRLOOP F3 S1 0.178665
AIRLOOP F3 S2 0.179367
AIRLOOP F4 SW 0.305293
AIRLOOP F4 NW 0.301585
AIRLOOP F4 SE 0.259986
AIRLOOP F4 NE 0.241660
AIRLOOP F4 N1 0.177395
AIRLOOP F4 N2 0.176449
AIRLOOP F4 S1 0.181006
AIRLOOP F4 S2 0.181513
AIRLOOP M SW 0.309726
AIRLOOP M NW 0.306020
AIRLOOP M SE 0.264811
AIRLOOP M NE 0.245977
AIRLOOP M N1 0.181630
AIRLOOP M N2 0.180694
AIRLOOP M S1 0.185193
AIRLOOP M S2 0.185673
AIRLOOP F6 SW 0.307669
AIRLOOP F6 NW 0.303807
AIRLOOP F6 SE 0.263385
AIRLOOP F6 NE 0.243878
AIRLOOP F6 N1 0.179498
AIRLOOP F6 N2 0.178576
AIRLOOP F6 S1 0.183135
AIRLOOP F6 S2 0.183612
AIRLOOP F7 SW 0.307801
AIRLOOP F7 NW 0.303895
AIRLOOP F7 SE 0.264060
AIRLOOP F7 NE 0.244039
AIRLOOP F7 N1 0.179560
AIRLOOP F7 N2 0.178647
AIRLOOP F7 S1 0.183193
AIRLOOP F7 S2 0.183670
AIRLOOP F8 SW 0.309410
AIRLOOP F8 NW 0.305470
AIRLOOP F8 SE 0.266078
AIRLOOP F8 NE 0.246051
AIRLOOP F8 N1 0.181098
AIRLOOP F8 N2 0.180196
AIRLOOP F8 S1 0.184681
AIRLOOP F8 S2 0.185136
AIRLOOP F9 SW 0.321616
AIRLOOP F9 NW 0.317888
AIRLOOP F9 SE 0.276457
AIRLOOP F9 NE 0.257370
AIRLOOP F9 N1 0.192278
AIRLOOP F9 N2 0.191377
AIRLOOP F9 S1 0.193501
AIRLOOP F9 S2 0.193942
AIRLOOP T SW 0.411338
AIRLOOP T NW 0.400966
AIRLOOP T SE 0.363921
AIRLOOP T NE 0.339353
AIRLOOP T N1 0.261372
AIRLOOP T N2 0.261071
AIRLOOP T S1 0.284844
AIRLOOP T S2 0.285223


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
AIRLOOP G SW OA CONTROLLER 0.244365 0.025952
AIRLOOP G NW OA CONTROLLER 0.241788 0.025952
AIRLOOP OFFICE OA CONTROLLER 0.358063 0.038103
AIRLOOP G NE OA CONTROLLER 0.186792 0.025952
AIRLOOP G N1 OA CONTROLLER 0.137045 0.025952
AIRLOOP G N2 OA CONTROLLER 0.135840 0.025952
AIRLOOP G S1 OA CONTROLLER 0.138200 0.025952
AIRLOOP G S2 OA CONTROLLER 0.144687 0.025952
AIRLOOP F2 SW OA CONTROLLER 0.300885 0.025952
AIRLOOP F2 NW OA CONTROLLER 0.296853 0.025952
AIRLOOP F2 SE OA CONTROLLER 0.278016 0.025952
AIRLOOP F2 NE OA CONTROLLER 0.235682 0.025952
AIRLOOP F2 N1 OA CONTROLLER 0.172003 0.025952
AIRLOOP F2 N2 OA CONTROLLER 0.171029 0.025952
AIRLOOP F2 S1 OA CONTROLLER 0.175253 0.025952
AIRLOOP F2 S2 OA CONTROLLER 0.177274 0.025952
AIRLOOP F3 SW OA CONTROLLER 0.302868 0.025952
AIRLOOP F3 NW OA CONTROLLER 0.299210 0.025952
AIRLOOP F3 SE OA CONTROLLER 0.258984 0.025952
AIRLOOP F3 NE OA CONTROLLER 0.239366 0.025952
AIRLOOP F3 N1 OA CONTROLLER 0.175073 0.025952
AIRLOOP F3 N2 OA CONTROLLER 0.174115 0.025952
AIRLOOP F3 S1 OA CONTROLLER 0.178665 0.025952
AIRLOOP F3 S2 OA CONTROLLER 0.179367 0.025952
AIRLOOP F4 SW OA CONTROLLER 0.305293 0.025952
AIRLOOP F4 NW OA CONTROLLER 0.301585 0.025952
AIRLOOP F4 SE OA CONTROLLER 0.259986 0.025952
AIRLOOP F4 NE OA CONTROLLER 0.241660 0.025952
AIRLOOP F4 N1 OA CONTROLLER 0.177395 0.025952
AIRLOOP F4 N2 OA CONTROLLER 0.176449 0.025952
AIRLOOP F4 S1 OA CONTROLLER 0.181006 0.025952
AIRLOOP F4 S2 OA CONTROLLER 0.181513 0.025952
AIRLOOP M SW OA CONTROLLER 0.309726 0.025952
AIRLOOP M NW OA CONTROLLER 0.306020 0.025952
AIRLOOP M SE OA CONTROLLER 0.264811 0.025952
AIRLOOP M NE OA CONTROLLER 0.245977 0.025952
AIRLOOP M N1 OA CONTROLLER 0.181630 0.025952
AIRLOOP M N2 OA CONTROLLER 0.180694 0.025952
AIRLOOP M S1 OA CONTROLLER 0.185193 0.025952
AIRLOOP M S2 OA CONTROLLER 0.185673 0.025952
AIRLOOP F6 SW OA CONTROLLER 0.307669 0.025952
AIRLOOP F6 NW OA CONTROLLER 0.303807 0.025952
AIRLOOP F6 SE OA CONTROLLER 0.263385 0.025952
AIRLOOP F6 NE OA CONTROLLER 0.243878 0.025952
AIRLOOP F6 N1 OA CONTROLLER 0.179498 0.025952
AIRLOOP F6 N2 OA CONTROLLER 0.178576 0.025952
AIRLOOP F6 S1 OA CONTROLLER 0.183135 0.025952
AIRLOOP F6 S2 OA CONTROLLER 0.183612 0.025952
AIRLOOP F7 SW OA CONTROLLER 0.307801 0.025952
AIRLOOP F7 NW OA CONTROLLER 0.303895 0.025952
AIRLOOP F7 SE OA CONTROLLER 0.264060 0.025952
AIRLOOP F7 NE OA CONTROLLER 0.244039 0.025952
AIRLOOP F7 N1 OA CONTROLLER 0.179560 0.025952
AIRLOOP F7 N2 OA CONTROLLER 0.178647 0.025952
AIRLOOP F7 S1 OA CONTROLLER 0.183193 0.025952
AIRLOOP F7 S2 OA CONTROLLER 0.183670 0.025952
AIRLOOP F8 SW OA CONTROLLER 0.309410 0.025952
AIRLOOP F8 NW OA CONTROLLER 0.305470 0.025952
AIRLOOP F8 SE OA CONTROLLER 0.266078 0.025952
AIRLOOP F8 NE OA CONTROLLER 0.246051 0.025952
AIRLOOP F8 N1 OA CONTROLLER 0.181098 0.025952
AIRLOOP F8 N2 OA CONTROLLER 0.180196 0.025952
AIRLOOP F8 S1 OA CONTROLLER 0.184681 0.025952
AIRLOOP F8 S2 OA CONTROLLER 0.185136 0.025952
AIRLOOP F9 SW OA CONTROLLER 0.321616 0.025952
AIRLOOP F9 NW OA CONTROLLER 0.317888 0.025952
AIRLOOP F9 SE OA CONTROLLER 0.276457 0.025952
AIRLOOP F9 NE OA CONTROLLER 0.257370 0.025952
AIRLOOP F9 N1 OA CONTROLLER 0.192278 0.025952
AIRLOOP F9 N2 OA CONTROLLER 0.191377 0.025952
AIRLOOP F9 S1 OA CONTROLLER 0.193501 0.025952
AIRLOOP F9 S2 OA CONTROLLER 0.193942 0.025952
AIRLOOP T SW OA CONTROLLER 0.411338 0.025952
AIRLOOP T NW OA CONTROLLER 0.400966 0.025952
AIRLOOP T SE OA CONTROLLER 0.363921 0.025952
AIRLOOP T NE OA CONTROLLER 0.339353 0.025952
AIRLOOP T N1 OA CONTROLLER 0.261372 0.025952
AIRLOOP T N2 OA CONTROLLER 0.261071 0.025952
AIRLOOP T S1 OA CONTROLLER 0.284844 0.025952
AIRLOOP T S2 OA CONTROLLER 0.285223 0.025952


COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity [W] Rated Sensible Cooling Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP COOLING MODE AIRLOOP G SW 0.244365 3331.51 2202.53 0.000073
HEAT PUMP COOLING MODE AIRLOOP G NW 0.241788 3281.06 2172.23 0.000072
HEAT PUMP COOLING MODE AIRLOOP OFFICE 0.358063 4816.47 3203.36 0.000105
HEAT PUMP COOLING MODE AIRLOOP G NE 0.186792 2543.24 1687.17 0.000056
HEAT PUMP COOLING MODE AIRLOOP G N1 0.137045 1935.73 1265.39 0.000042
HEAT PUMP COOLING MODE AIRLOOP G N2 0.135840 1920.33 1255.04 0.000042
HEAT PUMP COOLING MODE AIRLOOP G S1 0.138200 2030.42 1308.69 0.000044
HEAT PUMP COOLING MODE AIRLOOP G S2 0.144687 2108.76 1363.00 0.000046
HEAT PUMP COOLING MODE AIRLOOP F2 SW 0.300885 4026.71 2679.14 0.000088
HEAT PUMP COOLING MODE AIRLOOP F2 NW 0.296853 3963.59 2638.95 0.000087
HEAT PUMP COOLING MODE AIRLOOP F2 SE 0.278016 3771.45 2498.92 0.000082
HEAT PUMP COOLING MODE AIRLOOP F2 NE 0.235682 3146.76 2101.37 0.000069
HEAT PUMP COOLING MODE AIRLOOP F2 N1 0.172003 2382.04 1567.84 0.000052
HEAT PUMP COOLING MODE AIRLOOP F2 N2 0.171029 2369.64 1559.50 0.000052
HEAT PUMP COOLING MODE AIRLOOP F2 S1 0.175253 2492.55 1625.60 0.000054
HEAT PUMP COOLING MODE AIRLOOP F2 S2 0.177274 2518.22 1642.95 0.000055
HEAT PUMP COOLING MODE AIRLOOP F3 SW 0.302868 4042.36 2694.22 0.000088
HEAT PUMP COOLING MODE AIRLOOP F3 NW 0.299210 3983.93 2657.21 0.000087
HEAT PUMP COOLING MODE AIRLOOP F3 SE 0.258984 3521.20 2334.69 0.000077
HEAT PUMP COOLING MODE AIRLOOP F3 NE 0.239366 3184.26 2131.03 0.000070
HEAT PUMP COOLING MODE AIRLOOP F3 N1 0.175073 2415.59 1593.04 0.000053
HEAT PUMP COOLING MODE AIRLOOP F3 N2 0.174115 2403.42 1584.85 0.000053
HEAT PUMP COOLING MODE AIRLOOP F3 S1 0.178665 2530.52 1653.83 0.000055
HEAT PUMP COOLING MODE AIRLOOP F3 S2 0.179367 2539.45 1659.86 0.000055
HEAT PUMP COOLING MODE AIRLOOP F4 SW 0.305293 4071.42 2716.14 0.000089
HEAT PUMP COOLING MODE AIRLOOP F4 NW 0.301585 4006.92 2676.09 0.000088
HEAT PUMP COOLING MODE AIRLOOP F4 SE 0.259986 3531.51 2343.70 0.000077
HEAT PUMP COOLING MODE AIRLOOP F4 NE 0.241660 3206.49 2149.29 0.000070
HEAT PUMP COOLING MODE AIRLOOP F4 N1 0.177395 2441.03 1612.12 0.000053
HEAT PUMP COOLING MODE AIRLOOP F4 N2 0.176449 2429.02 1604.03 0.000053
HEAT PUMP COOLING MODE AIRLOOP F4 S1 0.181006 2556.23 1673.13 0.000056
HEAT PUMP COOLING MODE AIRLOOP F4 S2 0.181513 2562.68 1677.48 0.000056
HEAT PUMP COOLING MODE AIRLOOP M SW 0.309726 4121.80 2752.82 0.000090
HEAT PUMP COOLING MODE AIRLOOP M NW 0.306020 4057.32 2712.78 0.000089
HEAT PUMP COOLING MODE AIRLOOP M SE 0.264811 3587.07 2383.83 0.000078
HEAT PUMP COOLING MODE AIRLOOP M NE 0.245977 3255.56 2185.02 0.000071
HEAT PUMP COOLING MODE AIRLOOP M N1 0.181630 2491.53 1647.71 0.000054
HEAT PUMP COOLING MODE AIRLOOP M N2 0.180694 2479.65 1639.71 0.000054
HEAT PUMP COOLING MODE AIRLOOP M S1 0.185193 2606.07 1708.39 0.000057
HEAT PUMP COOLING MODE AIRLOOP M S2 0.185673 2612.18 1712.51 0.000057
HEAT PUMP COOLING MODE AIRLOOP F6 SW 0.307669 4090.88 2734.34 0.000089
HEAT PUMP COOLING MODE AIRLOOP F6 NW 0.303807 4024.40 2692.98 0.000088
HEAT PUMP COOLING MODE AIRLOOP F6 SE 0.263385 3564.39 2370.77 0.000078
HEAT PUMP COOLING MODE AIRLOOP F6 NE 0.243878 3237.61 2171.66 0.000071
HEAT PUMP COOLING MODE AIRLOOP F6 N1 0.179498 2461.61 1628.92 0.000054
HEAT PUMP COOLING MODE AIRLOOP F6 N2 0.178576 2449.89 1621.03 0.000054
HEAT PUMP COOLING MODE AIRLOOP F6 S1 0.183135 2577.23 1690.22 0.000056
HEAT PUMP COOLING MODE AIRLOOP F6 S2 0.183612 2583.30 1694.31 0.000056
HEAT PUMP COOLING MODE AIRLOOP F7 SW 0.307801 4088.29 2734.65 0.000089
HEAT PUMP COOLING MODE AIRLOOP F7 NW 0.303895 4021.23 2692.90 0.000088
HEAT PUMP COOLING MODE AIRLOOP F7 SE 0.264060 3568.84 2375.74 0.000078
HEAT PUMP COOLING MODE AIRLOOP F7 NE 0.244039 3235.61 2172.26 0.000071
HEAT PUMP COOLING MODE AIRLOOP F7 N1 0.179560 2459.91 1628.97 0.000054
HEAT PUMP COOLING MODE AIRLOOP F7 N2 0.178647 2448.33 1621.17 0.000053
HEAT PUMP COOLING MODE AIRLOOP F7 S1 0.183193 2575.67 1690.27 0.000056
HEAT PUMP COOLING MODE AIRLOOP F7 S2 0.183670 2581.61 1694.33 0.000056
HEAT PUMP COOLING MODE AIRLOOP F8 SW 0.309410 4104.83 2747.63 0.000090
HEAT PUMP COOLING MODE AIRLOOP F8 NW 0.305470 4037.33 2705.59 0.000088
HEAT PUMP COOLING MODE AIRLOOP F8 SE 0.266078 3590.71 2392.26 0.000078
HEAT PUMP COOLING MODE AIRLOOP F8 NE 0.246051 3332.70 2219.30 0.000073
HEAT PUMP COOLING MODE AIRLOOP F8 N1 0.181098 2477.23 1641.70 0.000054
HEAT PUMP COOLING MODE AIRLOOP F8 N2 0.180196 2465.79 1633.99 0.000054
HEAT PUMP COOLING MODE AIRLOOP F8 S1 0.184681 2592.36 1702.60 0.000057
HEAT PUMP COOLING MODE AIRLOOP F8 S2 0.185136 2598.03 1706.48 0.000057
HEAT PUMP COOLING MODE AIRLOOP F9 SW 0.321616 4250.32 2848.37 0.000093
HEAT PUMP COOLING MODE AIRLOOP F9 NW 0.317888 4190.91 2810.71 0.000092
HEAT PUMP COOLING MODE AIRLOOP F9 SE 0.276457 3718.63 2480.18 0.000081
HEAT PUMP COOLING MODE AIRLOOP F9 NE 0.257370 3472.36 2315.25 0.000076
HEAT PUMP COOLING MODE AIRLOOP F9 N1 0.192278 2617.11 1736.89 0.000057
HEAT PUMP COOLING MODE AIRLOOP F9 N2 0.191377 2605.68 1729.19 0.000057
HEAT PUMP COOLING MODE AIRLOOP F9 S1 0.193501 2702.00 1777.75 0.000059
HEAT PUMP COOLING MODE AIRLOOP F9 S2 0.193942 2707.60 1781.53 0.000059
HEAT PUMP COOLING MODE AIRLOOP T SW 0.411338 5405.36 3622.37 0.000118
HEAT PUMP COOLING MODE AIRLOOP T NW 0.400966 5261.53 3528.82 0.000115
HEAT PUMP COOLING MODE AIRLOOP T SE 0.363921 4821.01 3225.05 0.000105
HEAT PUMP COOLING MODE AIRLOOP T NE 0.339353 4510.40 3015.73 0.000099
HEAT PUMP COOLING MODE AIRLOOP T N1 0.261372 3559.47 2357.55 0.000078
HEAT PUMP COOLING MODE AIRLOOP T N2 0.261071 3555.69 2354.99 0.000078
HEAT PUMP COOLING MODE AIRLOOP T S1 0.284844 3856.69 2557.89 0.000084
HEAT PUMP COOLING MODE AIRLOOP T S2 0.285223 3861.51 2561.13 0.000084


AirLoopHVAC:UnitaryHeatPump:WaterToAir

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Supplemental Heating Coil Nominal Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
AIRLOOP G SW DXAC HEAT PUMP 0.244365 0.244365 0.244365 0.244365 3331.51 3331.51 2461.24 1.00
AIRLOOP G NW DXAC HEAT PUMP 0.241788 0.241788 0.241788 0.241788 3281.06 3281.06 2460.11 1.00
AIRLOOP OFFICE DXAC HEAT PUMP 0.358063 0.358063 0.358063 0.358063 4816.47 4816.47 3141.65 1.00
AIRLOOP G NE DXAC HEAT PUMP 0.186792 0.186792 0.186792 0.186792 2543.24 2543.24 2456.67 1.00
AIRLOOP G N1 DXAC HEAT PUMP 0.137045 0.137045 0.137045 0.137045 1935.73 1935.73 1835.78 1.00
AIRLOOP G N2 DXAC HEAT PUMP 0.135840 0.135840 0.135840 0.135840 1920.33 1920.33 1835.69 1.00
AIRLOOP G S1 DXAC HEAT PUMP 0.138200 0.138200 0.138200 0.138200 2030.42 2030.42 1833.23 1.00
AIRLOOP G S2 DXAC HEAT PUMP 0.144687 0.144687 0.144687 0.144687 2108.76 2108.76 1839.42 1.00
AIRLOOP F2 SW DXAC HEAT PUMP 0.300885 0.300885 0.300885 0.300885 4026.71 4026.71 2399.64 1.00
AIRLOOP F2 NW DXAC HEAT PUMP 0.296853 0.296853 0.296853 0.296853 3963.59 3963.59 2394.45 1.00
AIRLOOP F2 SE DXAC HEAT PUMP 0.278016 0.278016 0.278016 0.278016 3771.45 3771.45 2414.91 1.00
AIRLOOP F2 NE DXAC HEAT PUMP 0.235682 0.235682 0.235682 0.235682 3146.76 3146.76 2390.93 1.00
AIRLOOP F2 N1 DXAC HEAT PUMP 0.172003 0.172003 0.172003 0.172003 2382.04 2382.04 1626.68 1.00
AIRLOOP F2 N2 DXAC HEAT PUMP 0.171029 0.171029 0.171029 0.171029 2369.64 2369.64 1626.59 1.00
AIRLOOP F2 S1 DXAC HEAT PUMP 0.175253 0.175253 0.175253 0.175253 2492.55 2492.55 1634.55 1.00
AIRLOOP F2 S2 DXAC HEAT PUMP 0.177274 0.177274 0.177274 0.177274 2518.22 2518.22 1635.71 1.00
AIRLOOP F3 SW DXAC HEAT PUMP 0.302868 0.302868 0.302868 0.302868 4042.36 4042.36 2388.67 1.00
AIRLOOP F3 NW DXAC HEAT PUMP 0.299210 0.299210 0.299210 0.299210 3983.93 3983.93 2385.15 1.00
AIRLOOP F3 SE DXAC HEAT PUMP 0.258984 0.258984 0.258984 0.258984 3521.20 3521.20 2387.87 1.00
AIRLOOP F3 NE DXAC HEAT PUMP 0.239366 0.239366 0.239366 0.239366 3184.26 3184.26 2382.24 1.00
AIRLOOP F3 N1 DXAC HEAT PUMP 0.175073 0.175073 0.175073 0.175073 2415.59 2415.59 1588.37 1.00
AIRLOOP F3 N2 DXAC HEAT PUMP 0.174115 0.174115 0.174115 0.174115 2403.42 2403.42 1588.29 1.00
AIRLOOP F3 S1 DXAC HEAT PUMP 0.178665 0.178665 0.178665 0.178665 2530.52 2530.52 1592.58 1.00
AIRLOOP F3 S2 DXAC HEAT PUMP 0.179367 0.179367 0.179367 0.179367 2539.45 2539.45 1592.70 1.00
AIRLOOP F4 SW DXAC HEAT PUMP 0.305293 0.305293 0.305293 0.305293 4071.42 4071.42 2423.32 1.00
AIRLOOP F4 NW DXAC HEAT PUMP 0.301585 0.301585 0.301585 0.301585 4006.92 4006.92 2421.20 1.00
AIRLOOP F4 SE DXAC HEAT PUMP 0.259986 0.259986 0.259986 0.259986 3531.51 3531.51 2421.22 1.00
AIRLOOP F4 NE DXAC HEAT PUMP 0.241660 0.241660 0.241660 0.241660 3206.49 3206.49 2418.88 1.00
AIRLOOP F4 N1 DXAC HEAT PUMP 0.177395 0.177395 0.177395 0.177395 2441.03 2441.03 1600.81 1.00
AIRLOOP F4 N2 DXAC HEAT PUMP 0.176449 0.176449 0.176449 0.176449 2429.02 2429.02 1600.75 1.00
AIRLOOP F4 S1 DXAC HEAT PUMP 0.181006 0.181006 0.181006 0.181006 2556.23 2556.23 1603.37 1.00
AIRLOOP F4 S2 DXAC HEAT PUMP 0.181513 0.181513 0.181513 0.181513 2562.68 2562.68 1603.34 1.00
AIRLOOP M SW DXAC HEAT PUMP 0.309726 0.309726 0.309726 0.309726 4121.80 4121.80 2438.78 1.00
AIRLOOP M NW DXAC HEAT PUMP 0.306020 0.306020 0.306020 0.306020 4057.32 4057.32 2436.67 1.00
AIRLOOP M SE DXAC HEAT PUMP 0.264811 0.264811 0.264811 0.264811 3587.07 3587.07 2437.02 1.00
AIRLOOP M NE DXAC HEAT PUMP 0.245977 0.245977 0.245977 0.245977 3255.56 3255.56 2434.88 1.00
AIRLOOP M N1 DXAC HEAT PUMP 0.181630 0.181630 0.181630 0.181630 2491.53 2491.53 1599.56 1.00
AIRLOOP M N2 DXAC HEAT PUMP 0.180694 0.180694 0.180694 0.180694 2479.65 2479.65 1599.52 1.00
AIRLOOP M S1 DXAC HEAT PUMP 0.185193 0.185193 0.185193 0.185193 2606.07 2606.07 1602.09 1.00
AIRLOOP M S2 DXAC HEAT PUMP 0.185673 0.185673 0.185673 0.185673 2612.18 2612.18 1602.04 1.00
AIRLOOP F6 SW DXAC HEAT PUMP 0.307669 0.307669 0.307669 0.307669 4090.88 4090.88 2513.61 1.00
AIRLOOP F6 NW DXAC HEAT PUMP 0.303807 0.303807 0.303807 0.303807 4024.40 4024.40 2513.07 1.00
AIRLOOP F6 SE DXAC HEAT PUMP 0.263385 0.263385 0.263385 0.263385 3564.39 3564.39 2512.30 1.00
AIRLOOP F6 NE DXAC HEAT PUMP 0.243878 0.243878 0.243878 0.243878 3237.61 3237.61 2511.76 1.00
AIRLOOP F6 N1 DXAC HEAT PUMP 0.179498 0.179498 0.179498 0.179498 2461.61 2461.61 1657.05 1.00
AIRLOOP F6 N2 DXAC HEAT PUMP 0.178576 0.178576 0.178576 0.178576 2449.89 2449.89 1657.02 1.00
AIRLOOP F6 S1 DXAC HEAT PUMP 0.183135 0.183135 0.183135 0.183135 2577.23 2577.23 1657.94 1.00
AIRLOOP F6 S2 DXAC HEAT PUMP 0.183612 0.183612 0.183612 0.183612 2583.30 2583.30 1657.91 1.00
AIRLOOP F7 SW DXAC HEAT PUMP 0.307801 0.307801 0.307801 0.307801 4088.29 4088.29 2563.07 1.00
AIRLOOP F7 NW DXAC HEAT PUMP 0.303895 0.303895 0.303895 0.303895 4021.23 4021.23 2562.98 1.00
AIRLOOP F7 SE DXAC HEAT PUMP 0.264060 0.264060 0.264060 0.264060 3568.84 3568.84 2562.19 1.00
AIRLOOP F7 NE DXAC HEAT PUMP 0.244039 0.244039 0.244039 0.244039 3235.61 3235.61 2562.10 1.00
AIRLOOP F7 N1 DXAC HEAT PUMP 0.179560 0.179560 0.179560 0.179560 2459.91 2459.91 1692.83 1.00
AIRLOOP F7 N2 DXAC HEAT PUMP 0.178647 0.178647 0.178647 0.178647 2448.33 2448.33 1692.80 1.00
AIRLOOP F7 S1 DXAC HEAT PUMP 0.183193 0.183193 0.183193 0.183193 2575.67 2575.67 1693.22 1.00
AIRLOOP F7 S2 DXAC HEAT PUMP 0.183670 0.183670 0.183670 0.183670 2581.61 2581.61 1693.20 1.00
AIRLOOP F8 SW DXAC HEAT PUMP 0.309410 0.309410 0.309410 0.309410 4104.83 4104.83 2616.62 1.00
AIRLOOP F8 NW DXAC HEAT PUMP 0.305470 0.305470 0.305470 0.305470 4037.33 4037.33 2616.75 1.00
AIRLOOP F8 SE DXAC HEAT PUMP 0.266078 0.266078 0.266078 0.266078 3590.71 3590.71 2616.15 1.00
AIRLOOP F8 NE DXAC HEAT PUMP 0.246051 0.246051 0.246051 0.246051 3332.70 3332.70 2616.27 1.00
AIRLOOP F8 N1 DXAC HEAT PUMP 0.181098 0.181098 0.181098 0.181098 2477.23 2477.23 1734.17 1.00
AIRLOOP F8 N2 DXAC HEAT PUMP 0.180196 0.180196 0.180196 0.180196 2465.79 2465.79 1734.16 1.00
AIRLOOP F8 S1 DXAC HEAT PUMP 0.184681 0.184681 0.184681 0.184681 2592.36 2592.36 1734.34 1.00
AIRLOOP F8 S2 DXAC HEAT PUMP 0.185136 0.185136 0.185136 0.185136 2598.03 2598.03 1734.33 1.00
AIRLOOP F9 SW DXAC HEAT PUMP 0.321616 0.321616 0.321616 0.321616 4250.32 4250.32 2783.15 1.00
AIRLOOP F9 NW DXAC HEAT PUMP 0.317888 0.317888 0.317888 0.317888 4190.91 4190.91 2781.30 1.00
AIRLOOP F9 SE DXAC HEAT PUMP 0.276457 0.276457 0.276457 0.276457 3718.63 3718.63 2783.04 1.00
AIRLOOP F9 NE DXAC HEAT PUMP 0.257370 0.257370 0.257370 0.257370 3472.36 3472.36 2781.20 1.00
AIRLOOP F9 N1 DXAC HEAT PUMP 0.192278 0.192278 0.192278 0.192278 2617.11 2617.11 1879.90 1.00
AIRLOOP F9 N2 DXAC HEAT PUMP 0.191377 0.191377 0.191377 0.191377 2605.68 2605.68 1879.90 1.00
AIRLOOP F9 S1 DXAC HEAT PUMP 0.193501 0.193501 0.193501 0.193501 2702.00 2702.00 1881.61 1.00
AIRLOOP F9 S2 DXAC HEAT PUMP 0.193942 0.193942 0.193942 0.193942 2707.60 2707.60 1881.60 1.00
AIRLOOP T SW DXAC HEAT PUMP 0.411338 0.411338 0.411338 0.411338 5405.36 5405.36 3352.96 1.00
AIRLOOP T NW DXAC HEAT PUMP 0.400966 0.400966 0.400966 0.400966 5261.53 5261.53 3357.81 1.00
AIRLOOP T SE DXAC HEAT PUMP 0.363921 0.363921 0.363921 0.363921 4821.01 4821.01 3353.16 1.00
AIRLOOP T NE DXAC HEAT PUMP 0.339353 0.339353 0.339353 0.339353 4510.40 4510.40 3358.01 1.00
AIRLOOP T N1 DXAC HEAT PUMP 0.261372 0.261372 0.261372 0.261372 3559.47 3559.47 2497.15 1.00
AIRLOOP T N2 DXAC HEAT PUMP 0.261071 0.261071 0.261071 0.261071 3555.69 3555.69 2497.15 1.00
AIRLOOP T S1 DXAC HEAT PUMP 0.284844 0.284844 0.284844 0.284844 3856.69 3856.69 2489.37 1.00
AIRLOOP T S2 DXAC HEAT PUMP 0.285223 0.285223 0.285223 0.285223 3861.51 3861.51 2489.38 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
AIRLOOP G SW SUPPLY FAN 0.244365
AIRLOOP G NW SUPPLY FAN 0.241788
AIRLOOP OFFICE SUPPLY FAN 0.358063
AIRLOOP G NE SUPPLY FAN 0.186792
AIRLOOP G N1 SUPPLY FAN 0.137045
AIRLOOP G N2 SUPPLY FAN 0.135840
AIRLOOP G S1 SUPPLY FAN 0.138200
AIRLOOP G S2 SUPPLY FAN 0.144687
AIRLOOP F2 SW SUPPLY FAN 0.300885
AIRLOOP F2 NW SUPPLY FAN 0.296853
AIRLOOP F2 SE SUPPLY FAN 0.278016
AIRLOOP F2 NE SUPPLY FAN 0.235682
AIRLOOP F2 N1 SUPPLY FAN 0.172003
AIRLOOP F2 N2 SUPPLY FAN 0.171029
AIRLOOP F2 S1 SUPPLY FAN 0.175253
AIRLOOP F2 S2 SUPPLY FAN 0.177274
AIRLOOP F3 SW SUPPLY FAN 0.302868
AIRLOOP F3 NW SUPPLY FAN 0.299210
AIRLOOP F3 SE SUPPLY FAN 0.258984
AIRLOOP F3 NE SUPPLY FAN 0.239366
AIRLOOP F3 N1 SUPPLY FAN 0.175073
AIRLOOP F3 N2 SUPPLY FAN 0.174115
AIRLOOP F3 S1 SUPPLY FAN 0.178665
AIRLOOP F3 S2 SUPPLY FAN 0.179367
AIRLOOP F4 SW SUPPLY FAN 0.305293
AIRLOOP F4 NW SUPPLY FAN 0.301585
AIRLOOP F4 SE SUPPLY FAN 0.259986
AIRLOOP F4 NE SUPPLY FAN 0.241660
AIRLOOP F4 N1 SUPPLY FAN 0.177395
AIRLOOP F4 N2 SUPPLY FAN 0.176449
AIRLOOP F4 S1 SUPPLY FAN 0.181006
AIRLOOP F4 S2 SUPPLY FAN 0.181513
AIRLOOP M SW SUPPLY FAN 0.309726
AIRLOOP M NW SUPPLY FAN 0.306020
AIRLOOP M SE SUPPLY FAN 0.264811
AIRLOOP M NE SUPPLY FAN 0.245977
AIRLOOP M N1 SUPPLY FAN 0.181630
AIRLOOP M N2 SUPPLY FAN 0.180694
AIRLOOP M S1 SUPPLY FAN 0.185193
AIRLOOP M S2 SUPPLY FAN 0.185673
AIRLOOP F6 SW SUPPLY FAN 0.307669
AIRLOOP F6 NW SUPPLY FAN 0.303807
AIRLOOP F6 SE SUPPLY FAN 0.263385
AIRLOOP F6 NE SUPPLY FAN 0.243878
AIRLOOP F6 N1 SUPPLY FAN 0.179498
AIRLOOP F6 N2 SUPPLY FAN 0.178576
AIRLOOP F6 S1 SUPPLY FAN 0.183135
AIRLOOP F6 S2 SUPPLY FAN 0.183612
AIRLOOP F7 SW SUPPLY FAN 0.307801
AIRLOOP F7 NW SUPPLY FAN 0.303895
AIRLOOP F7 SE SUPPLY FAN 0.264060
AIRLOOP F7 NE SUPPLY FAN 0.244039
AIRLOOP F7 N1 SUPPLY FAN 0.179560
AIRLOOP F7 N2 SUPPLY FAN 0.178647
AIRLOOP F7 S1 SUPPLY FAN 0.183193
AIRLOOP F7 S2 SUPPLY FAN 0.183670
AIRLOOP F8 SW SUPPLY FAN 0.309410
AIRLOOP F8 NW SUPPLY FAN 0.305470
AIRLOOP F8 SE SUPPLY FAN 0.266078
AIRLOOP F8 NE SUPPLY FAN 0.246051
AIRLOOP F8 N1 SUPPLY FAN 0.181098
AIRLOOP F8 N2 SUPPLY FAN 0.180196
AIRLOOP F8 S1 SUPPLY FAN 0.184681
AIRLOOP F8 S2 SUPPLY FAN 0.185136
AIRLOOP F9 SW SUPPLY FAN 0.321616
AIRLOOP F9 NW SUPPLY FAN 0.317888
AIRLOOP F9 SE SUPPLY FAN 0.276457
AIRLOOP F9 NE SUPPLY FAN 0.257370
AIRLOOP F9 N1 SUPPLY FAN 0.192278
AIRLOOP F9 N2 SUPPLY FAN 0.191377
AIRLOOP F9 S1 SUPPLY FAN 0.193501
AIRLOOP F9 S2 SUPPLY FAN 0.193942
AIRLOOP T SW SUPPLY FAN 0.411338
AIRLOOP T NW SUPPLY FAN 0.400966
AIRLOOP T SE SUPPLY FAN 0.363921
AIRLOOP T NE SUPPLY FAN 0.339353
AIRLOOP T N1 SUPPLY FAN 0.261372
AIRLOOP T N2 SUPPLY FAN 0.261071
AIRLOOP T S1 SUPPLY FAN 0.284844
AIRLOOP T S2 SUPPLY FAN 0.285223


COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Heating Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP HEATING MODE AIRLOOP G SW 0.244365 3331.51 0.000073
HEAT PUMP HEATING MODE AIRLOOP G NW 0.241788 3281.06 0.000072
HEAT PUMP HEATING MODE AIRLOOP OFFICE 0.358063 4816.47 0.000105
HEAT PUMP HEATING MODE AIRLOOP G NE 0.186792 2543.24 0.000056
HEAT PUMP HEATING MODE AIRLOOP G N1 0.137045 1935.73 0.000042
HEAT PUMP HEATING MODE AIRLOOP G N2 0.135840 1920.33 0.000042
HEAT PUMP HEATING MODE AIRLOOP G S1 0.138200 2030.42 0.000044
HEAT PUMP HEATING MODE AIRLOOP G S2 0.144687 2108.76 0.000046
HEAT PUMP HEATING MODE AIRLOOP F2 SW 0.300885 4026.71 0.000088
HEAT PUMP HEATING MODE AIRLOOP F2 NW 0.296853 3963.59 0.000087
HEAT PUMP HEATING MODE AIRLOOP F2 SE 0.278016 3771.45 0.000082
HEAT PUMP HEATING MODE AIRLOOP F2 NE 0.235682 3146.76 0.000069
HEAT PUMP HEATING MODE AIRLOOP F2 N1 0.172003 2382.04 0.000052
HEAT PUMP HEATING MODE AIRLOOP F2 N2 0.171029 2369.64 0.000052
HEAT PUMP HEATING MODE AIRLOOP F2 S1 0.175253 2492.55 0.000054
HEAT PUMP HEATING MODE AIRLOOP F2 S2 0.177274 2518.22 0.000055
HEAT PUMP HEATING MODE AIRLOOP F3 SW 0.302868 4042.36 0.000088
HEAT PUMP HEATING MODE AIRLOOP F3 NW 0.299210 3983.93 0.000087
HEAT PUMP HEATING MODE AIRLOOP F3 SE 0.258984 3521.20 0.000077
HEAT PUMP HEATING MODE AIRLOOP F3 NE 0.239366 3184.26 0.000070
HEAT PUMP HEATING MODE AIRLOOP F3 N1 0.175073 2415.59 0.000053
HEAT PUMP HEATING MODE AIRLOOP F3 N2 0.174115 2403.42 0.000053
HEAT PUMP HEATING MODE AIRLOOP F3 S1 0.178665 2530.52 0.000055
HEAT PUMP HEATING MODE AIRLOOP F3 S2 0.179367 2539.45 0.000055
HEAT PUMP HEATING MODE AIRLOOP F4 SW 0.305293 4071.42 0.000089
HEAT PUMP HEATING MODE AIRLOOP F4 NW 0.301585 4006.92 0.000088
HEAT PUMP HEATING MODE AIRLOOP F4 SE 0.259986 3531.51 0.000077
HEAT PUMP HEATING MODE AIRLOOP F4 NE 0.241660 3206.49 0.000070
HEAT PUMP HEATING MODE AIRLOOP F4 N1 0.177395 2441.03 0.000053
HEAT PUMP HEATING MODE AIRLOOP F4 N2 0.176449 2429.02 0.000053
HEAT PUMP HEATING MODE AIRLOOP F4 S1 0.181006 2556.23 0.000056
HEAT PUMP HEATING MODE AIRLOOP F4 S2 0.181513 2562.68 0.000056
HEAT PUMP HEATING MODE AIRLOOP M SW 0.309726 4121.80 0.000090
HEAT PUMP HEATING MODE AIRLOOP M NW 0.306020 4057.32 0.000089
HEAT PUMP HEATING MODE AIRLOOP M SE 0.264811 3587.07 0.000078
HEAT PUMP HEATING MODE AIRLOOP M NE 0.245977 3255.56 0.000071
HEAT PUMP HEATING MODE AIRLOOP M N1 0.181630 2491.53 0.000054
HEAT PUMP HEATING MODE AIRLOOP M N2 0.180694 2479.65 0.000054
HEAT PUMP HEATING MODE AIRLOOP M S1 0.185193 2606.07 0.000057
HEAT PUMP HEATING MODE AIRLOOP M S2 0.185673 2612.18 0.000057
HEAT PUMP HEATING MODE AIRLOOP F6 SW 0.307669 4090.88 0.000089
HEAT PUMP HEATING MODE AIRLOOP F6 NW 0.303807 4024.40 0.000088
HEAT PUMP HEATING MODE AIRLOOP F6 SE 0.263385 3564.39 0.000078
HEAT PUMP HEATING MODE AIRLOOP F6 NE 0.243878 3237.61 0.000071
HEAT PUMP HEATING MODE AIRLOOP F6 N1 0.179498 2461.61 0.000054
HEAT PUMP HEATING MODE AIRLOOP F6 N2 0.178576 2449.89 0.000054
HEAT PUMP HEATING MODE AIRLOOP F6 S1 0.183135 2577.23 0.000056
HEAT PUMP HEATING MODE AIRLOOP F6 S2 0.183612 2583.30 0.000056
HEAT PUMP HEATING MODE AIRLOOP F7 SW 0.307801 4088.29 0.000089
HEAT PUMP HEATING MODE AIRLOOP F7 NW 0.303895 4021.23 0.000088
HEAT PUMP HEATING MODE AIRLOOP F7 SE 0.264060 3568.84 0.000078
HEAT PUMP HEATING MODE AIRLOOP F7 NE 0.244039 3235.61 0.000071
HEAT PUMP HEATING MODE AIRLOOP F7 N1 0.179560 2459.91 0.000054
HEAT PUMP HEATING MODE AIRLOOP F7 N2 0.178647 2448.33 0.000053
HEAT PUMP HEATING MODE AIRLOOP F7 S1 0.183193 2575.67 0.000056
HEAT PUMP HEATING MODE AIRLOOP F7 S2 0.183670 2581.61 0.000056
HEAT PUMP HEATING MODE AIRLOOP F8 SW 0.309410 4104.83 0.000090
HEAT PUMP HEATING MODE AIRLOOP F8 NW 0.305470 4037.33 0.000088
HEAT PUMP HEATING MODE AIRLOOP F8 SE 0.266078 3590.71 0.000078
HEAT PUMP HEATING MODE AIRLOOP F8 NE 0.246051 3332.70 0.000073
HEAT PUMP HEATING MODE AIRLOOP F8 N1 0.181098 2477.23 0.000054
HEAT PUMP HEATING MODE AIRLOOP F8 N2 0.180196 2465.79 0.000054
HEAT PUMP HEATING MODE AIRLOOP F8 S1 0.184681 2592.36 0.000057
HEAT PUMP HEATING MODE AIRLOOP F8 S2 0.185136 2598.03 0.000057
HEAT PUMP HEATING MODE AIRLOOP F9 SW 0.321616 4250.32 0.000093
HEAT PUMP HEATING MODE AIRLOOP F9 NW 0.317888 4190.91 0.000092
HEAT PUMP HEATING MODE AIRLOOP F9 SE 0.276457 3718.63 0.000081
HEAT PUMP HEATING MODE AIRLOOP F9 NE 0.257370 3472.36 0.000076
HEAT PUMP HEATING MODE AIRLOOP F9 N1 0.192278 2617.11 0.000057
HEAT PUMP HEATING MODE AIRLOOP F9 N2 0.191377 2605.68 0.000057
HEAT PUMP HEATING MODE AIRLOOP F9 S1 0.193501 2702.00 0.000059
HEAT PUMP HEATING MODE AIRLOOP F9 S2 0.193942 2707.60 0.000059
HEAT PUMP HEATING MODE AIRLOOP T SW 0.411338 5405.36 0.000118
HEAT PUMP HEATING MODE AIRLOOP T NW 0.400966 5261.53 0.000115
HEAT PUMP HEATING MODE AIRLOOP T SE 0.363921 4821.01 0.000105
HEAT PUMP HEATING MODE AIRLOOP T NE 0.339353 4510.40 0.000099
HEAT PUMP HEATING MODE AIRLOOP T N1 0.261372 3559.47 0.000078
HEAT PUMP HEATING MODE AIRLOOP T N2 0.261071 3555.69 0.000078
HEAT PUMP HEATING MODE AIRLOOP T S1 0.284844 3856.69 0.000084
HEAT PUMP HEATING MODE AIRLOOP T S2 0.285223 3861.51 0.000084


Coil:Heating:Electric

Nominal Capacity [W]
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW 2461.24
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW 2460.11
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE 3141.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE 2456.67
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 1835.78
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 1835.69
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 1833.23
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 1839.42
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW 2399.64
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW 2394.45
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE 2414.91
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE 2390.93
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 1626.68
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 1626.59
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 1634.55
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 1635.71
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW 2388.67
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW 2385.15
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE 2387.87
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE 2382.24
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 1588.37
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 1588.29
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 1592.58
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 1592.70
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW 2423.32
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW 2421.20
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE 2421.22
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE 2418.88
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 1600.81
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 1600.75
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 1603.37
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 1603.34
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW 2438.78
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW 2436.67
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE 2437.02
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE 2434.88
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 1599.56
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 1599.52
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 1602.09
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 1602.04
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW 2513.61
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW 2513.07
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE 2512.30
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE 2511.76
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 1657.05
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 1657.02
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 1657.94
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 1657.91
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW 2563.07
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW 2562.98
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE 2562.19
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE 2562.10
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 1692.83
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 1692.80
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 1693.22
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 1693.20
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW 2616.62
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW 2616.75
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE 2616.15
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE 2616.27
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 1734.17
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 1734.16
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 1734.34
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 1734.33
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW 2783.15
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW 2781.30
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE 2783.04
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE 2781.20
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 1879.90
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 1879.90
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 1881.61
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 1881.60
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW 3352.96
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW 3357.81
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE 3353.16
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE 3358.01
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 2497.15
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 2497.15
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 2489.37
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 2489.38


PlantLoop

Maximum Loop Flow Rate [m3/s] Plant Loop Volume [m3]
SHWSYS1 0.000289 0.325214
SINGLE WATER PLANT LOOP 0.005626 6.33


Boiler:HotWater

Design Water Flow Rate [m3/s]
CENTRAL BOILER 0.005626


WaterHeater:Mixed

Use Side Design Flow Rate [m3/s]
SHWSYS1 WATER HEATER 0.000289


EvaporativeFluidCooler:SingleSpeed

Design Water Flow Rate [m3/s] Fan Power at Design Air Flow Rate [W] Design Air Flow Rate [m3/s] U-Factor Times Area Value at Design Air Flow Rate [W/C]
CENTRAL TOWER 0.005626 2715.84 8.24 7301.46


Pump:ConstantSpeed

Rated Flow Rate [m3/s] Rated Power Consumption [W]
SHWSYS1 PUMP 0.000289 36.93
PLANT CIRC PUMP 0.005626 1796.59



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW3 |
G WWALL SWA GWINDOW2 |
G NWALL NWA GWINDOW4 |
G WWALL NWA GWINDOW6 |
G SWALL SEA GWINDOW1 |
G EWALL SEA GWINDOW8 |
G NWALL NEA GWINDOW5 |
G EWALL NEA GWINDOW7 |
G NWALL N1A GWINDOW9 |
G NWALL N2A GWINDOW10 |
G SWALL S1A GWINDOW11 |
G SWALL S2A GWINDOW12 |
G WWALL C GWINDOW13 |
G EWALL C ENTRANCE DOOR |
F2 WWALL SWA F2WINDOW2 |
F2 SWALL SWA F2WINDOW3 |
F2 NWALL NWA F2WINDOW4 |
F2 WWALL NWA F2WINDOW6 |
F2 EWALL SEA F2WINDOW8 |
F2 SWALL SEA F2WINDOW1 |
F2 NWALL NEA F2WINDOW5 |
F2 EWALL NEA F2WINDOW7 |
F2 NWALL N1A F2WINDOW9 |
F2 NWALL N2A F2WINDOW10 |
F2 SWALL S1A F2WINDOW11 |
F2 SWALL S2A F2WINDOW12 |
F2 WWALL C F2WINDOW13 |
F2 EWALL C F2WINDOW14 |
F3 WWALL SWA F3WINDOW2 |
F3 SWALL SWA F3WINDOW3 |
F3 NWALL NWA F3WINDOW4 |
F3 WWALL NWA F3WINDOW6 |
F3 EWALL SEA F3WINDOW8 |
F3 SWALL SEA F3WINDOW1 |
F3 NWALL NEA F3WINDOW5 |
F3 EWALL NEA F3WINDOW7 |
F3 NWALL N1A F3WINDOW9 |
F3 NWALL N2A F3WINDOW10 |
F3 SWALL S1A F3WINDOW11 |
F3 SWALL S2A F3WINDOW12 |
F3 WWALL C F3WINDOW13 |
F3 EWALL C F3WINDOW14 |
F4 WWALL SWA F4WINDOW2 |
F4 SWALL SWA F4WINDOW3 |
F4 NWALL NWA F4WINDOW4 |
F4 WWALL NWA F4WINDOW6 |
F4 EWALL SEA F4WINDOW8 |
F4 SWALL SEA F4WINDOW1 |
F4 NWALL NEA F4WINDOW5 |
F4 EWALL NEA F4WINDOW7 |
F4 NWALL N1A F4WINDOW9 |
F4 NWALL N2A F4WINDOW10 |
F4 SWALL S1A F4WINDOW11 |
F4 SWALL S2A F4WINDOW12 |
F4 WWALL C F4WINDOW13 |
F4 EWALL C F4WINDOW14 |
M WWALL SWA MWINDOW2 |
M SWALL SWA MWINDOW3 |
M NWALL NWA MWINDOW4 |
M WWALL NWA MWINDOW6 |
M EWALL SEA MWINDOW8 |
M SWALL SEA MWINDOW1 |
M NWALL NEA MWINDOW5 |
M EWALL NEA MWINDOW7 |
M NWALL N1A MWINDOW9 |
M NWALL N2A MWINDOW10 |
M SWALL S1A MWINDOW11 |
M SWALL S2A MWINDOW12 |
M WWALL C MWINDOW13 |
M EWALL C MWINDOW14 |
F6 WWALL SWA F6WINDOW2 |
F6 SWALL SWA F6WINDOW3 |
F6 NWALL NWA F6WINDOW4 |
F6 WWALL NWA F6WINDOW6 |
F6 EWALL SEA F6WINDOW8 |
F6 SWALL SEA F6WINDOW1 |
F6 NWALL NEA F6WINDOW5 |
F6 EWALL NEA F6WINDOW7 |
F6 NWALL N1A F6WINDOW9 |
F6 NWALL N2A F6WINDOW10 |
F6 SWALL S1A F6WINDOW11 |
F6 SWALL S2A F6WINDOW12 |
F6 WWALL C F6WINDOW13 |
F6 EWALL C F6WINDOW14 |
F7 WWALL SWA F7WINDOW2 |
F7 SWALL SWA F7WINDOW3 |
F7 NWALL NWA F7WINDOW4 |
F7 WWALL NWA F7WINDOW6 |
F7 EWALL SEA F7WINDOW8 |
F7 SWALL SEA F7WINDOW1 |
F7 NWALL NEA F7WINDOW5 |
F7 EWALL NEA F7WINDOW7 |
F7 NWALL N1A F7WINDOW9 |
F7 NWALL N2A F7WINDOW10 |
F7 SWALL S1A F7WINDOW11 |
F7 SWALL S2A F7WINDOW12 |
F7 WWALL C F7WINDOW13 |
F7 EWALL C F7WINDOW14 |
F8 WWALL SWA F8WINDOW2 |
F8 SWALL SWA F8WINDOW3 |
F8 NWALL NWA F8WINDOW4 |
F8 WWALL NWA F8WINDOW6 |
F8 EWALL SEA F8WINDOW8 |
F8 SWALL SEA F8WINDOW1 |
F8 NWALL NEA F8WINDOW5 |
F8 EWALL NEA F8WINDOW7 |
F8 NWALL N1A F8WINDOW9 |
F8 NWALL N2A F8WINDOW10 |
F8 SWALL S1A F8WINDOW11 |
F8 SWALL S2A F8WINDOW12 |
F8 WWALL C F8WINDOW13 |
F8 EWALL C F8WINDOW14 |
F9 WWALL SWA F9WINDOW2 |
F9 SWALL SWA F9WINDOW3 |
F9 NWALL NWA F9WINDOW4 |
F9 WWALL NWA F9WINDOW6 |
F9 EWALL SEA F9WINDOW8 |
F9 SWALL SEA F9WINDOW1 |
F9 NWALL NEA F9WINDOW5 |
F9 EWALL NEA F9WINDOW7 |
F9 NWALL N1A F9WINDOW9 |
F9 NWALL N2A F9WINDOW10 |
F9 SWALL S1A F9WINDOW11 |
F9 SWALL S2A F9WINDOW12 |
F9 WWALL C F9WINDOW13 |
F9 EWALL C F9WINDOW14 |
T WWALL SWA TWINDOW2 |
T SWALL SWA TWINDOW3 |
T NWALL NWA TWINDOW4 |
T WWALL NWA TWINDOW6 |
T EWALL SEA TWINDOW8 |
T SWALL SEA TWINDOW1 |
T NWALL NEA TWINDOW5 |
T EWALL NEA TWINDOW7 |
T NWALL N1A TWINDOW9 |
T NWALL N2A TWINDOW10 |
T SWALL S1A TWINDOW11 |
T SWALL S2A TWINDOW12 |
T WWALL C TWINDOW13 |
T EWALL C TWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:30

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.69 8.14
February 22.84 10.27
March 23.00 12.55
April 23.79 19.23
May 24.21 23.84
June 24.39 27.86
July 24.40 27.54
August 24.38 26.28
September 24.34 23.38
October 24.00 18.30
November 23.17 11.18
December 22.67 6.79
     
Annual Sum or Average 23.66 17.98
Minimum of Months 22.67 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.87 8.14
February 22.10 10.27
March 22.48 12.55
April 23.67 19.23
May 24.21 23.84
June 24.40 27.86
July 24.40 27.54
August 24.38 26.28
September 24.33 23.38
October 23.73 18.30
November 22.32 11.18
December 21.85 6.79
     
Annual Sum or Average 23.32 17.98
Minimum of Months 21.85 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.88 8.14
February 23.19 10.27
March 23.44 12.55
April 24.11 19.23
May 24.37 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.40 23.38
October 24.19 18.30
November 23.37 11.18
December 22.84 6.79
     
Annual Sum or Average 23.84 17.98
Minimum of Months 22.84 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.78 8.14
February 22.05 10.27
March 22.42 12.55
April 23.69 19.23
May 24.23 23.84
June 24.40 27.86
July 24.41 27.54
August 24.38 26.28
September 24.34 23.38
October 23.64 18.30
November 22.20 11.18
December 21.78 6.79
     
Annual Sum or Average 23.28 17.98
Minimum of Months 21.78 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.76 8.14
February 21.95 10.27
March 22.24 12.55
April 23.52 19.23
May 24.16 23.84
June 24.39 27.86
July 24.41 27.54
August 24.37 26.28
September 24.31 23.38
October 23.57 18.30
November 22.13 11.18
December 21.77 6.79
     
Annual Sum or Average 23.22 17.98
Minimum of Months 21.76 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.76 8.14
February 21.95 10.27
March 22.24 12.55
April 23.52 19.23
May 24.16 23.84
June 24.39 27.86
July 24.41 27.54
August 24.37 26.28
September 24.31 23.38
October 23.56 18.30
November 22.12 11.18
December 21.76 6.79
     
Annual Sum or Average 23.22 17.98
Minimum of Months 21.76 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.75 8.14
February 22.88 10.27
March 22.95 12.55
April 23.71 19.23
May 24.17 23.84
June 24.38 27.86
July 24.40 27.54
August 24.38 26.28
September 24.38 23.38
October 23.98 18.30
November 23.23 11.18
December 22.74 6.79
     
Annual Sum or Average 23.67 17.98
Minimum of Months 22.74 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.79 8.14
February 22.93 10.27
March 23.02 12.55
April 23.75 19.23
May 24.18 23.84
June 24.38 27.86
July 24.40 27.54
August 24.38 26.28
September 24.37 23.38
October 24.01 18.30
November 23.27 11.18
December 22.78 6.79
     
Annual Sum or Average 23.69 17.98
Minimum of Months 22.78 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 18.86 8.14
February 19.70 10.27
March 20.62 12.55
April 23.14 19.23
May 24.91 23.84
June 26.81 27.86
July 26.78 27.54
August 26.35 26.28
September 25.57 23.38
October 23.03 18.30
November 20.22 11.18
December 18.52 6.79
     
Annual Sum or Average 22.89 17.98
Minimum of Months 18.52 6.79
Maximum of Months 26.81 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.28 8.14
February 23.51 10.27
March 23.72 12.55
April 24.17 19.23
May 24.34 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.38 23.38
October 24.33 18.30
November 23.80 11.18
December 23.23 6.79
     
Annual Sum or Average 24.00 17.98
Minimum of Months 23.23 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.08 8.14
February 22.49 10.27
March 23.02 12.55
April 24.06 19.23
May 24.34 23.84
June 24.41 27.86
July 24.40 27.54
August 24.39 26.28
September 24.37 23.38
October 24.18 18.30
November 22.84 11.18
December 22.03 6.79
     
Annual Sum or Average 23.56 17.98
Minimum of Months 22.03 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.35 8.14
February 23.62 10.27
March 23.83 12.55
April 24.24 19.23
May 24.37 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.39 23.38
October 24.34 18.30
November 23.84 11.18
December 23.32 6.79
     
Annual Sum or Average 24.04 17.98
Minimum of Months 23.32 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.96 8.14
February 22.42 10.27
March 22.94 12.55
April 24.07 19.23
May 24.35 23.84
June 24.41 27.86
July 24.41 27.54
August 24.39 26.28
September 24.37 23.38
October 24.11 18.30
November 22.67 11.18
December 21.94 6.79
     
Annual Sum or Average 23.51 17.98
Minimum of Months 21.94 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.99 8.14
February 22.38 10.27
March 22.85 12.55
April 23.99 19.23
May 24.32 23.84
June 24.40 27.86
July 24.41 27.54
August 24.39 26.28
September 24.36 23.38
October 24.11 18.30
November 22.68 11.18
December 21.96 6.79
     
Annual Sum or Average 23.49 17.98
Minimum of Months 21.96 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.99 8.14
February 22.37 10.27
March 22.84 12.55
April 23.99 19.23
May 24.32 23.84
June 24.40 27.86
July 24.41 27.54
August 24.39 26.28
September 24.36 23.38
October 24.11 18.30
November 22.66 11.18
December 21.96 6.79
     
Annual Sum or Average 23.49 17.98
Minimum of Months 21.96 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.53 8.14
February 23.68 10.27
March 23.79 12.55
April 24.14 19.23
May 24.33 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.42 23.38
October 24.35 18.30
November 23.92 11.18
December 23.47 6.79
     
Annual Sum or Average 24.07 17.98
Minimum of Months 23.47 6.79
Maximum of Months 24.42 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.54 8.14
February 23.70 10.27
March 23.81 12.55
April 24.15 19.23
May 24.33 23.84
June 24.39 27.86
July 24.40 27.54
August 24.39 26.28
September 24.41 23.38
October 24.35 18.30
November 23.93 11.18
December 23.49 6.79
     
Annual Sum or Average 24.08 17.98
Minimum of Months 23.49 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.17 8.14
February 23.63 10.27
March 24.13 12.55
April 25.38 19.23
May 26.06 23.84
June 26.63 27.86
July 26.61 27.54
August 26.50 26.28
September 26.33 23.38
October 25.53 18.30
November 24.06 11.18
December 23.06 6.79
     
Annual Sum or Average 25.10 17.98
Minimum of Months 23.06 6.79
Maximum of Months 26.63 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.39 8.14
February 23.60 10.27
March 23.81 12.55
April 24.18 19.23
May 24.34 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.38 23.38
October 24.35 18.30
November 23.87 11.18
December 23.33 6.79
     
Annual Sum or Average 24.04 17.98
Minimum of Months 23.33 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.14 8.14
February 22.58 10.27
March 23.13 12.55
April 24.09 19.23
May 24.34 23.84
June 24.41 27.86
July 24.40 27.54
August 24.39 26.28
September 24.37 23.38
October 24.23 18.30
November 22.97 11.18
December 22.09 6.79
     
Annual Sum or Average 23.60 17.98
Minimum of Months 22.09 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.34 8.14
February 23.60 10.27
March 23.80 12.55
April 24.21 19.23
May 24.36 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.39 23.38
October 24.34 18.30
November 23.83 11.18
December 23.31 6.79
     
Annual Sum or Average 24.03 17.98
Minimum of Months 23.31 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.00 8.14
February 22.51 10.27
March 23.06 12.55
April 24.10 19.23
May 24.36 23.84
June 24.42 27.86
July 24.41 27.54
August 24.39 26.28
September 24.37 23.38
October 24.18 18.30
November 22.80 11.18
December 21.99 6.79
     
Annual Sum or Average 23.55 17.98
Minimum of Months 21.99 6.79
Maximum of Months 24.42 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.10 8.14
February 22.53 10.27
March 23.05 12.55
April 24.06 19.23
May 24.33 23.84
June 24.41 27.86
July 24.41 27.54
August 24.39 26.28
September 24.36 23.38
October 24.19 18.30
November 22.89 11.18
December 22.05 6.79
     
Annual Sum or Average 23.57 17.98
Minimum of Months 22.05 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.09 8.14
February 22.53 10.27
March 23.04 12.55
April 24.06 19.23
May 24.33 23.84
June 24.41 27.86
July 24.41 27.54
August 24.39 26.28
September 24.36 23.38
October 24.19 18.30
November 22.87 11.18
December 22.05 6.79
     
Annual Sum or Average 23.56 17.98
Minimum of Months 22.05 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.71 8.14
February 23.84 10.27
March 23.93 12.55
April 24.18 19.23
May 24.33 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.42 23.38
October 24.38 18.30
November 24.03 11.18
December 23.65 6.79
     
Annual Sum or Average 24.14 17.98
Minimum of Months 23.65 6.79
Maximum of Months 24.42 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.71 8.14
February 23.85 10.27
March 23.94 12.55
April 24.19 19.23
May 24.34 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.42 23.38
October 24.38 18.30
November 24.03 11.18
December 23.66 6.79
     
Annual Sum or Average 24.14 17.98
Minimum of Months 23.66 6.79
Maximum of Months 24.42 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.65 8.14
February 24.10 10.27
March 24.58 12.55
April 25.71 19.23
May 26.28 23.84
June 26.68 27.86
July 26.64 27.54
August 26.55 26.28
September 26.42 23.38
October 25.86 18.30
November 24.53 11.18
December 23.55 6.79
     
Annual Sum or Average 25.38 17.98
Minimum of Months 23.55 6.79
Maximum of Months 26.68 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.38 8.14
February 23.59 10.27
March 23.80 12.55
April 24.17 19.23
May 24.34 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.38 23.38
October 24.35 18.30
November 23.87 11.18
December 23.33 6.79
     
Annual Sum or Average 24.04 17.98
Minimum of Months 23.33 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.16 8.14
February 22.59 10.27
March 23.15 12.55
April 24.08 19.23
May 24.34 23.84
June 24.41 27.86
July 24.40 27.54
August 24.39 26.28
September 24.37 23.38
October 24.23 18.30
November 22.99 11.18
December 22.11 6.79
     
Annual Sum or Average 23.61 17.98
Minimum of Months 22.11 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.32 8.14
February 23.56 10.27
March 23.78 12.55
April 24.19 19.23
May 24.36 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.39 23.38
October 24.34 18.30
November 23.81 11.18
December 23.29 6.79
     
Annual Sum or Average 24.02 17.98
Minimum of Months 23.29 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.02 8.14
February 22.52 10.27
March 23.07 12.55
April 24.09 19.23
May 24.35 23.84
June 24.42 27.86
July 24.41 27.54
August 24.39 26.28
September 24.37 23.38
October 24.18 18.30
November 22.82 11.18
December 22.00 6.79
     
Annual Sum or Average 23.56 17.98
Minimum of Months 22.00 6.79
Maximum of Months 24.42 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.15 8.14
February 22.58 10.27
March 23.11 12.55
April 24.06 19.23
May 24.33 23.84
June 24.41 27.86
July 24.41 27.54
August 24.39 26.28
September 24.36 23.38
October 24.21 18.30
November 22.95 11.18
December 22.09 6.79
     
Annual Sum or Average 23.59 17.98
Minimum of Months 22.09 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.14 8.14
February 22.57 10.27
March 23.10 12.55
April 24.06 19.23
May 24.33 23.84
June 24.41 27.86
July 24.41 27.54
August 24.39 26.28
September 24.36 23.38
October 24.21 18.30
November 22.93 11.18
December 22.08 6.79
     
Annual Sum or Average 23.59 17.98
Minimum of Months 22.08 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.74 8.14
February 23.86 10.27
March 23.95 12.55
April 24.18 19.23
May 24.33 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.42 23.38
October 24.38 18.30
November 24.04 11.18
December 23.68 6.79
     
Annual Sum or Average 24.15 17.98
Minimum of Months 23.68 6.79
Maximum of Months 24.42 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.73 8.14
February 23.86 10.27
March 23.95 12.55
April 24.18 19.23
May 24.33 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.42 23.38
October 24.38 18.30
November 24.04 11.18
December 23.68 6.79
     
Annual Sum or Average 24.15 17.98
Minimum of Months 23.68 6.79
Maximum of Months 24.42 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.80 8.14
February 24.25 10.27
March 24.73 12.55
April 25.82 19.23
May 26.38 23.84
June 26.76 27.86
July 26.71 27.54
August 26.62 26.28
September 26.50 23.38
October 25.99 18.30
November 24.68 11.18
December 23.71 6.79
     
Annual Sum or Average 25.50 17.98
Minimum of Months 23.71 6.79
Maximum of Months 26.76 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.36 8.14
February 23.57 10.27
March 23.76 12.55
April 24.15 19.23
May 24.34 23.84
June 24.41 27.86
July 24.40 27.54
August 24.39 26.28
September 24.38 23.38
October 24.34 18.30
November 23.86 11.18
December 23.31 6.79
     
Annual Sum or Average 24.02 17.98
Minimum of Months 23.31 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.16 8.14
February 22.58 10.27
March 23.12 12.55
April 24.06 19.23
May 24.33 23.84
June 24.41 27.86
July 24.40 27.54
August 24.39 26.28
September 24.37 23.38
October 24.23 18.30
November 22.99 11.18
December 22.12 6.79
     
Annual Sum or Average 23.60 17.98
Minimum of Months 22.12 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.30 8.14
February 23.53 10.27
March 23.74 12.55
April 24.17 19.23
May 24.35 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.39 23.38
October 24.33 18.30
November 23.80 11.18
December 23.27 6.79
     
Annual Sum or Average 24.01 17.98
Minimum of Months 23.27 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.02 8.14
February 22.52 10.27
March 23.04 12.55
April 24.07 19.23
May 24.35 23.84
June 24.43 27.86
July 24.41 27.54
August 24.39 26.28
September 24.37 23.38
October 24.18 18.30
November 22.81 11.18
December 22.01 6.79
     
Annual Sum or Average 23.56 17.98
Minimum of Months 22.01 6.79
Maximum of Months 24.43 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.17 8.14
February 22.59 10.27
March 23.11 12.55
April 24.05 19.23
May 24.32 23.84
June 24.41 27.86
July 24.41 27.54
August 24.39 26.28
September 24.36 23.38
October 24.21 18.30
November 22.97 11.18
December 22.11 6.79
     
Annual Sum or Average 23.60 17.98
Minimum of Months 22.11 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.16 8.14
February 22.59 10.27
March 23.10 12.55
April 24.05 19.23
May 24.32 23.84
June 24.41 27.86
July 24.41 27.54
August 24.39 26.28
September 24.36 23.38
October 24.21 18.30
November 22.96 11.18
December 22.11 6.79
     
Annual Sum or Average 23.59 17.98
Minimum of Months 22.11 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.73 8.14
February 23.85 10.27
March 23.94 12.55
April 24.17 19.23
May 24.33 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.41 23.38
October 24.38 18.30
November 24.04 11.18
December 23.68 6.79
     
Annual Sum or Average 24.14 17.98
Minimum of Months 23.68 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.73 8.14
February 23.85 10.27
March 23.94 12.55
April 24.17 19.23
May 24.33 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.41 23.38
October 24.38 18.30
November 24.04 11.18
December 23.68 6.79
     
Annual Sum or Average 24.14 17.98
Minimum of Months 23.68 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.36 8.14
February 24.79 10.27
March 25.26 12.55
April 26.34 19.23
May 26.91 23.84
June 27.28 27.86
July 27.24 27.54
August 27.15 26.28
September 27.03 23.38
October 26.53 18.30
November 25.24 11.18
December 24.27 6.79
     
Annual Sum or Average 26.04 17.98
Minimum of Months 24.27 6.79
Maximum of Months 27.28 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.27 8.14
February 23.47 10.27
March 23.65 12.55
April 24.11 19.23
May 24.32 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.38 23.38
October 24.32 18.30
November 23.80 11.18
December 23.23 6.79
     
Annual Sum or Average 23.98 17.98
Minimum of Months 23.23 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.09 8.14
February 22.48 10.27
March 22.98 12.55
April 24.01 19.23
May 24.32 23.84
June 24.41 27.86
July 24.40 27.54
August 24.39 26.28
September 24.37 23.38
October 24.19 18.30
November 22.87 11.18
December 22.06 6.79
     
Annual Sum or Average 23.55 17.98
Minimum of Months 22.06 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.21 8.14
February 23.44 10.27
March 23.63 12.55
April 24.13 19.23
May 24.34 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.39 23.38
October 24.31 18.30
November 23.74 11.18
December 23.19 6.79
     
Annual Sum or Average 23.97 17.98
Minimum of Months 23.19 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.96 8.14
February 22.43 10.27
March 22.92 12.55
April 24.03 19.23
May 24.34 23.84
June 24.43 27.86
July 24.41 27.54
August 24.39 26.28
September 24.37 23.38
October 24.13 18.30
November 22.70 11.18
December 21.96 6.79
     
Annual Sum or Average 23.51 17.98
Minimum of Months 21.96 6.79
Maximum of Months 24.43 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.09 8.14
February 22.49 10.27
March 22.97 12.55
April 24.00 19.23
May 24.31 23.84
June 24.41 27.86
July 24.41 27.54
August 24.39 26.28
September 24.36 23.38
October 24.17 18.30
November 22.85 11.18
December 22.05 6.79
     
Annual Sum or Average 23.55 17.98
Minimum of Months 22.05 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.08 8.14
February 22.48 10.27
March 22.96 12.55
April 24.01 19.23
May 24.31 23.84
June 24.41 27.86
July 24.41 27.54
August 24.39 26.28
September 24.36 23.38
October 24.17 18.30
November 22.83 11.18
December 22.04 6.79
     
Annual Sum or Average 23.54 17.98
Minimum of Months 22.04 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.65 8.14
February 23.76 10.27
March 23.84 12.55
April 24.13 19.23
May 24.32 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.41 23.38
October 24.36 18.30
November 23.99 11.18
December 23.60 6.79
     
Annual Sum or Average 24.10 17.98
Minimum of Months 23.60 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.64 8.14
February 23.76 10.27
March 23.84 12.55
April 24.13 19.23
May 24.32 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.41 23.38
October 24.36 18.30
November 23.99 11.18
December 23.60 6.79
     
Annual Sum or Average 24.10 17.98
Minimum of Months 23.60 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.71 8.14
February 24.14 10.27
March 24.59 12.55
April 25.75 19.23
May 26.35 23.84
June 26.75 27.86
July 26.70 27.54
August 26.61 26.28
September 26.48 23.38
October 25.94 18.30
November 24.59 11.18
December 23.64 6.79
     
Annual Sum or Average 25.44 17.98
Minimum of Months 23.64 6.79
Maximum of Months 26.75 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.20 8.14
February 23.39 10.27
March 23.56 12.55
April 24.08 19.23
May 24.32 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.37 23.38
October 24.31 18.30
November 23.75 11.18
December 23.17 6.79
     
Annual Sum or Average 23.95 17.98
Minimum of Months 23.17 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.04 8.14
February 22.42 10.27
March 22.88 12.55
April 23.98 19.23
May 24.31 23.84
June 24.41 27.86
July 24.40 27.54
August 24.39 26.28
September 24.36 23.38
October 24.16 18.30
November 22.78 11.18
December 22.02 6.79
     
Annual Sum or Average 23.52 17.98
Minimum of Months 22.02 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.14 8.14
February 23.36 10.27
March 23.54 12.55
April 24.10 19.23
May 24.33 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.39 23.38
October 24.29 18.30
November 23.69 11.18
December 23.13 6.79
     
Annual Sum or Average 23.93 17.98
Minimum of Months 23.13 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.92 8.14
February 22.37 10.27
March 22.82 12.55
April 23.99 19.23
May 24.33 23.84
June 24.43 27.86
July 24.41 27.54
August 24.39 26.28
September 24.37 23.38
October 24.09 18.30
November 22.61 11.18
December 21.93 6.79
     
Annual Sum or Average 23.48 17.98
Minimum of Months 21.92 6.79
Maximum of Months 24.43 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.03 8.14
February 22.42 10.27
March 22.86 12.55
April 23.97 19.23
May 24.30 23.84
June 24.41 27.86
July 24.41 27.54
August 24.39 26.28
September 24.36 23.38
October 24.15 18.30
November 22.76 11.18
December 22.01 6.79
     
Annual Sum or Average 23.51 17.98
Minimum of Months 22.01 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.02 8.14
February 22.42 10.27
March 22.86 12.55
April 23.97 19.23
May 24.30 23.84
June 24.41 27.86
July 24.41 27.54
August 24.39 26.28
September 24.36 23.38
October 24.14 18.30
November 22.74 11.18
December 22.01 6.79
     
Annual Sum or Average 23.51 17.98
Minimum of Months 22.01 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.57 8.14
February 23.69 10.27
March 23.76 12.55
April 24.09 19.23
May 24.31 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.40 23.38
October 24.35 18.30
November 23.95 11.18
December 23.53 6.79
     
Annual Sum or Average 24.07 17.98
Minimum of Months 23.53 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.57 8.14
February 23.69 10.27
March 23.76 12.55
April 24.10 19.23
May 24.31 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.40 23.38
October 24.35 18.30
November 23.95 11.18
December 23.53 6.79
     
Annual Sum or Average 24.07 17.98
Minimum of Months 23.53 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.55 8.14
February 23.97 10.27
March 24.40 12.55
April 25.62 19.23
May 26.27 23.84
June 26.68 27.86
July 26.64 27.54
August 26.54 26.28
September 26.41 23.38
October 25.83 18.30
November 24.43 11.18
December 23.48 6.79
     
Annual Sum or Average 25.32 17.98
Minimum of Months 23.48 6.79
Maximum of Months 26.68 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.14 8.14
February 23.32 10.27
March 23.48 12.55
April 24.05 19.23
May 24.31 23.84
June 24.41 27.86
July 24.40 27.54
August 24.39 26.28
September 24.37 23.38
October 24.30 18.30
November 23.70 11.18
December 23.11 6.79
     
Annual Sum or Average 23.92 17.98
Minimum of Months 23.11 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.01 8.14
February 22.37 10.27
March 22.81 12.55
April 23.95 19.23
May 24.30 23.84
June 24.41 27.86
July 24.40 27.54
August 24.39 26.28
September 24.36 23.38
October 24.13 18.30
November 22.71 11.18
December 21.99 6.79
     
Annual Sum or Average 23.49 17.98
Minimum of Months 21.99 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.08 8.14
February 23.30 10.27
March 23.46 12.55
April 24.07 19.23
May 24.33 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.38 23.38
October 24.27 18.30
November 23.65 11.18
December 23.07 6.79
     
Annual Sum or Average 23.90 17.98
Minimum of Months 23.07 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.90 8.14
February 22.32 10.27
March 22.75 12.55
April 23.97 19.23
May 24.32 23.84
June 24.42 27.86
July 24.41 27.54
August 24.39 26.28
September 24.37 23.38
October 24.06 18.30
November 22.55 11.18
December 21.91 6.79
     
Annual Sum or Average 23.45 17.98
Minimum of Months 21.90 6.79
Maximum of Months 24.42 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.00 8.14
February 22.37 10.27
March 22.78 12.55
April 23.95 19.23
May 24.29 23.84
June 24.41 27.86
July 24.41 27.54
August 24.39 26.28
September 24.35 23.38
October 24.12 18.30
November 22.68 11.18
December 21.98 6.79
     
Annual Sum or Average 23.48 17.98
Minimum of Months 21.98 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.99 8.14
February 22.36 10.27
March 22.78 12.55
April 23.95 19.23
May 24.30 23.84
June 24.41 27.86
July 24.41 27.54
August 24.39 26.28
September 24.35 23.38
October 24.12 18.30
November 22.67 11.18
December 21.97 6.79
     
Annual Sum or Average 23.48 17.98
Minimum of Months 21.97 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.50 8.14
February 23.62 10.27
March 23.68 12.55
April 24.07 19.23
May 24.30 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.40 23.38
October 24.34 18.30
November 23.91 11.18
December 23.46 6.79
     
Annual Sum or Average 24.04 17.98
Minimum of Months 23.46 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.49 8.14
February 23.62 10.27
March 23.68 12.55
April 24.07 19.23
May 24.30 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.40 23.38
October 24.34 18.30
November 23.91 11.18
December 23.46 6.79
     
Annual Sum or Average 24.04 17.98
Minimum of Months 23.46 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.45 8.14
February 23.87 10.27
March 24.28 12.55
April 25.58 19.23
May 26.26 23.84
June 26.69 27.86
July 26.65 27.54
August 26.54 26.28
September 26.40 23.38
October 25.79 18.30
November 24.33 11.18
December 23.38 6.79
     
Annual Sum or Average 25.27 17.98
Minimum of Months 23.38 6.79
Maximum of Months 26.69 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.05 8.14
February 23.23 10.27
March 23.39 12.55
April 24.02 19.23
May 24.30 23.84
June 24.41 27.86
July 24.40 27.54
August 24.39 26.28
September 24.37 23.38
October 24.27 18.30
November 23.62 11.18
December 23.03 6.79
     
Annual Sum or Average 23.88 17.98
Minimum of Months 23.03 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.99 8.14
February 22.34 10.27
March 22.76 12.55
April 23.92 19.23
May 24.30 23.84
June 24.41 27.86
July 24.40 27.54
August 24.39 26.28
September 24.36 23.38
October 24.10 18.30
November 22.65 11.18
December 21.97 6.79
     
Annual Sum or Average 23.47 17.98
Minimum of Months 21.97 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.00 8.14
February 23.22 10.27
March 23.37 12.55
April 24.04 19.23
May 24.32 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.38 23.38
October 24.24 18.30
November 23.57 11.18
December 22.99 6.79
     
Annual Sum or Average 23.86 17.98
Minimum of Months 22.99 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.88 8.14
February 22.30 10.27
March 22.71 12.55
April 23.94 19.23
May 24.31 23.84
June 24.42 27.86
July 24.41 27.54
August 24.39 26.28
September 24.37 23.38
October 24.02 18.30
November 22.49 11.18
December 21.89 6.79
     
Annual Sum or Average 23.43 17.98
Minimum of Months 21.88 6.79
Maximum of Months 24.42 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.97 8.14
February 22.33 10.27
March 22.73 12.55
April 23.92 19.23
May 24.29 23.84
June 24.41 27.86
July 24.41 27.54
August 24.39 26.28
September 24.35 23.38
October 24.09 18.30
November 22.61 11.18
December 21.95 6.79
     
Annual Sum or Average 23.46 17.98
Minimum of Months 21.95 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.96 8.14
February 22.33 10.27
March 22.73 12.55
April 23.93 19.23
May 24.29 23.84
June 24.41 27.86
July 24.41 27.54
August 24.39 26.28
September 24.35 23.38
October 24.08 18.30
November 22.60 11.18
December 21.95 6.79
     
Annual Sum or Average 23.46 17.98
Minimum of Months 21.95 6.79
Maximum of Months 24.41 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.37 8.14
February 23.51 10.27
March 23.57 12.55
April 24.04 19.23
May 24.30 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.39 23.38
October 24.32 18.30
November 23.83 11.18
December 23.34 6.79
     
Annual Sum or Average 23.99 17.98
Minimum of Months 23.34 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.37 8.14
February 23.51 10.27
March 23.57 12.55
April 24.04 19.23
May 24.30 23.84
June 24.40 27.86
July 24.40 27.54
August 24.39 26.28
September 24.39 23.38
October 24.31 18.30
November 23.83 11.18
December 23.34 6.79
     
Annual Sum or Average 23.99 17.98
Minimum of Months 23.34 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.30 8.14
February 23.75 10.27
March 24.18 12.55
April 25.58 19.23
May 26.33 23.84
June 26.82 27.86
July 26.77 27.54
August 26.65 26.28
September 26.48 23.38
October 25.76 18.30
November 24.20 11.18
December 23.23 6.79
     
Annual Sum or Average 25.26 17.98
Minimum of Months 23.23 6.79
Maximum of Months 26.82 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.82 8.14
February 23.00 10.27
March 23.15 12.55
April 23.89 19.23
May 24.25 23.84
June 24.39 27.86
July 24.40 27.54
August 24.38 26.28
September 24.34 23.38
October 24.09 18.30
November 23.28 11.18
December 22.82 6.79
     
Annual Sum or Average 23.74 17.98
Minimum of Months 22.82 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.16 8.14
February 22.43 10.27
March 22.74 12.55
April 23.81 19.23
May 24.25 23.84
June 24.40 27.86
July 24.40 27.54
August 24.38 26.28
September 24.32 23.38
October 23.90 18.30
November 22.66 11.18
December 22.16 6.79
     
Annual Sum or Average 23.47 17.98
Minimum of Months 22.16 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.80 8.14
February 22.98 10.27
March 23.15 12.55
April 23.92 19.23
May 24.28 23.84
June 24.39 27.86
July 24.40 27.54
August 24.38 26.28
September 24.35 23.38
October 24.05 18.30
November 23.24 11.18
December 22.81 6.79
     
Annual Sum or Average 23.73 17.98
Minimum of Months 22.80 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.03 8.14
February 22.41 10.27
March 22.72 12.55
April 23.84 19.23
May 24.27 23.84
June 24.40 27.86
July 24.40 27.54
August 24.38 26.28
September 24.33 23.38
October 23.84 18.30
November 22.54 11.18
December 22.04 6.79
     
Annual Sum or Average 23.44 17.98
Minimum of Months 22.03 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.09 8.14
February 22.39 10.27
March 22.70 12.55
April 23.82 19.23
May 24.25 23.84
June 24.39 27.86
July 24.40 27.54
August 24.38 26.28
September 24.31 23.38
October 23.92 18.30
November 22.60 11.18
December 22.07 6.79
     
Annual Sum or Average 23.45 17.98
Minimum of Months 22.07 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.08 8.14
February 22.39 10.27
March 22.70 12.55
April 23.82 19.23
May 24.25 23.84
June 24.39 27.86
July 24.40 27.54
August 24.38 26.28
September 24.31 23.38
October 23.92 18.30
November 22.59 11.18
December 22.06 6.79
     
Annual Sum or Average 23.45 17.98
Minimum of Months 22.06 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.00 8.14
February 23.19 10.27
March 23.28 12.55
April 23.93 19.23
May 24.26 23.84
June 24.39 27.86
July 24.40 27.54
August 24.38 26.28
September 24.35 23.38
October 24.18 18.30
November 23.46 11.18
December 22.99 6.79
     
Annual Sum or Average 23.82 17.98
Minimum of Months 22.99 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.00 8.14
February 23.19 10.27
March 23.29 12.55
April 23.93 19.23
May 24.26 23.84
June 24.39 27.86
July 24.40 27.54
August 24.38 26.28
September 24.35 23.38
October 24.18 18.30
November 23.45 11.18
December 22.99 6.79
     
Annual Sum or Average 23.82 17.98
Minimum of Months 22.99 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2015-09-09 19:00:30

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.43 8.14
February 23.98 10.27
March 24.51 12.55
April 26.20 19.23
May 27.13 23.84
June 27.84 27.86
July 27.80 27.54
August 27.61 26.28
September 27.28 23.38
October 26.25 18.30
November 24.39 11.18
December 23.29 6.79
     
Annual Sum or Average 25.82 17.98
Minimum of Months 23.29 6.79
Maximum of Months 27.84 27.86



Table of Contents

Report: COMPONENTS OF PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2015-09-09 19:00:30

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY {AT MAX/MIN} [W] HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W]
January 0.219868E+12 115309.641 02-JAN-18:15 13120.457 57042.023 22038.649 0.000 8607.827 10364.000 1833.522 315.352 0.000 0.000 0.000 0.000 0.000 0.000 0.000
February 0.196895E+12 124882.929 23-FEB-18:45 13120.457 57042.023 22038.649 18496.270 0.000 10364.000 1833.522 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
March 0.213439E+12 134733.724 21-MAR-16:15 11327.174 57142.088 22038.649 0.000 39186.502 0.000 1833.522 1210.593 0.000 0.000 0.000 0.000 0.000 0.000 0.000
April 0.243107E+12 159018.747 21-APR-19:30 14401.373 49889.926 22038.649 0.000 57172.852 10364.000 1833.522 1677.122 0.000 0.000 0.000 0.000 0.000 0.000 0.000
May 0.282953E+12 161295.026 19-MAY-17:15 13120.457 57042.023 22038.649 0.000 63211.557 0.000 1833.522 2061.006 0.000 0.000 0.000 0.000 0.000 0.000 0.000
June 0.306755E+12 164932.931 14-JUN-19:15 14401.373 49889.926 22038.649 0.000 62805.975 10364.000 1833.522 1958.181 0.000 0.000 0.000 0.000 0.000 0.000 0.000
July 0.328232E+12 165905.791 17-JUL-19:00 14401.373 49889.926 22038.649 0.000 63390.957 10364.000 1833.522 2346.059 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 0.311634E+12 164054.064 07-AUG-18:00 14401.373 51749.961 22038.649 0.000 59786.260 10364.000 1833.522 2119.273 0.000 0.000 0.000 0.000 0.000 0.000 0.000
September 0.287734E+12 158929.557 15-SEP-18:30 14401.373 51749.961 22038.649 0.000 54809.465 10364.000 1833.522 1971.562 0.000 0.000 0.000 0.000 0.000 0.000 0.000
October 0.250078E+12 161398.300 05-OCT-17:45 13120.457 57042.023 22038.649 0.000 53044.857 10364.000 1833.522 1966.783 0.000 0.000 0.000 0.000 0.000 0.000 0.000
November 0.213757E+12 126050.204 03-NOV-16:15 11327.174 57142.088 22038.649 0.000 30453.495 0.000 1833.522 1260.080 0.000 0.000 0.000 0.000 0.000 0.000 0.000
December 0.221405E+12 115373.087 07-DEC-18:00 13120.457 57042.023 22038.649 0.000 8687.530 10364.000 1833.522 298.898 0.000 0.000 0.000 0.000 0.000 0.000 0.000
                                     
Annual Sum or Average 0.307586E+13                     0.000 0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.196895E+12 115309.641   11327.174 49889.926 22038.649 0.000 0.000 0.000 1833.522 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.328232E+12 165905.791   14401.373 57142.088 22038.649 18496.270 63390.957 10364.000 1833.522 2346.059 0.000 0.000 0.000 0.000 0.000 0.000 0.000



Table of Contents

Report: COMPONENTS OF PEAK GAS DEMAND

For: Meter

Timestamp: 2015-09-09 19:00:30

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC [Invalid/Undefined] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT {AT MAX/MIN} [W] WATERSYSTEMS:GAS {AT MAX/MIN} [W] WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] HEATING:GAS {AT MAX/MIN} [W]
January 0.113375E+12 156451.273 27-JAN-06:00 0.000 0.000 0.000 156451.273 75135.826 75135.826 81315.448
February 0.991224E+11 145933.386 02-FEB-06:30 0.000 0.000 0.000 145933.386 73167.262 73167.262 72766.124
March 0.960748E+11 127273.095 02-MAR-06:00 0.000 0.000 0.000 127273.095 74557.886 74557.886 52715.208
April 0.842838E+11 81115.041 11-APR-05:45 0.000 0.000 0.000 81115.041 72168.514 72168.514 8946.528
May 0.793840E+11 72650.350 01-MAY-06:45 0.000 0.000 0.000 72650.350 72650.350 72650.350 0.000
June 0.708862E+11 70531.161 02-JUN-06:00 0.000 0.000 0.000 70531.161 70531.161 70531.161 0.000
July 0.696886E+11 69151.443 02-JUL-06:00 0.000 0.000 0.000 69151.443 69151.443 69151.443 0.000
August 0.696887E+11 69162.369 30-AUG-06:00 0.000 0.000 0.000 69162.369 69162.369 69162.369 0.000
September 0.708857E+11 70509.808 29-SEP-06:45 0.000 0.000 0.000 70509.808 70509.808 70509.808 0.000
October 0.793892E+11 72664.754 31-OCT-06:00 0.000 0.000 0.000 72664.754 72664.754 72664.754 0.000
November 0.890291E+11 140875.871 28-NOV-06:45 0.000 0.000 0.000 140875.871 72656.310 72656.310 68219.561
December 0.114683E+12 158857.856 27-DEC-07:30 0.000 0.000 0.000 158857.856 76170.724 76170.724 82687.131
                     
Annual Sum or Average 0.103649E+13     0.000 0.000 0.000        
Minimum of Months 0.696886E+11 69151.443   0.000 0.000 0.000 69151.443 69151.443 69151.443 0.000
Maximum of Months 0.114683E+12 158857.856   0.000 0.000 0.000 158857.856 76170.724 76170.724 82687.131