Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 19:10
Tabular Output Report in Format: HTML
Building: High-Rise Apartment
Environment: Helena Regional Airport MT USA TMY3 WMO#=727720
Simulation Timestamp: 2015-09-09 19:11:13
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:13
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 5009.02 | 639.19 | 709.50 |
Net Site Energy | 5009.02 | 639.19 | 709.50 |
Total Source Energy | 11480.83 | 1465.05 | 1626.20 |
Net Source Energy | 11480.83 | 1465.05 | 1626.20 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 7836.48 |
Net Conditioned Building Area | 7059.89 |
Unconditioned Building Area | 776.58 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 235.82 | 852.88 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 234.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 296.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 162.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1137.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 737.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 56.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 8.43 | 0.00 | 0.00 | 0.00 | 0.00 | 846.14 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 1251.16 | 0.00 | 0.00 | 0.00 | 4778.51 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 2904.97 | 2104.04 | 0.00 | 0.00 | 0.00 | 5624.66 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Boiler | 0.00 | 852.88 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Other | 235.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 234.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 242.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 54.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 162.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 1137.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 737.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 56.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 8.43 | 0.00 | 0.00 | 0.00 | 0.00 | 846.14 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 1251.16 | 0.00 | 0.00 | 0.00 | 0.00 |
sub cat | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4778.51 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 65.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 180.22 | 298.03 | 0.00 | 0.00 | 0.00 | 0.80 |
Other | 161.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 411.48 | 298.03 | 0.00 | 0.00 | 0.00 | 0.80 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 58.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 162.36 | 268.49 | 0.00 | 0.00 | 0.00 | 0.72 |
Other | 145.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 370.70 | 268.49 | 0.00 | 0.00 | 0.00 | 0.72 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 2904.97 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 2904.97 | 100.00 |
Total On-Site and Utility Electric Sources | 2904.97 | 100.00 |
Total Electricity End Uses | 2904.97 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 5624.66 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 5624.66 | 100.00 |
Total Water End Uses | 5624.66 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 148.75 |
Time Setpoint Not Met During Occupied Cooling | 74.25 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 2179.50 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |COMPONENTS OF PEAK ELECTRICAL DEMAND
| Meter |COMPONENTS OF PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:13
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 19:10 |
RunPeriod | Helena Regional Airport MT USA TMY3 WMO#=727720 |
Weather File | Helena Regional Airport MT USA TMY3 WMO#=727720 |
Latitude [deg] | 46.60 |
Longitude [deg] | -112.0 |
Elevation [m] | 1167.00 |
Time Zone | -7.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 3855.02 | 1411.96 | 515.55 | 1411.96 | 515.55 |
Window Opening Area [m2] | 1150.39 | 423.59 | 152.73 | 423.59 | 150.48 |
Window-Wall Ratio [%] | 29.84 | 30.00 | 29.62 | 30.00 | 29.19 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 3752.84 | 1411.96 | 464.46 | 1411.96 | 464.46 |
Window Opening Area [m2] | 1125.85 | 423.59 | 139.34 | 423.59 | 139.34 |
Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 29.5362 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 4.47 | 6.7128 | 0.0000 | |
F2 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F2 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F2 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F3 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F3 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F3 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F4 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F4 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F4 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
M SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 13.4255 | 0.0000 | |
F6 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F6 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F6 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F7 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F7 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F7 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F8 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F8 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F8 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
F9 SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
F9 N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
F9 CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 0.0000 | |
T SW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 58.52 | 17.56 | 3.6746 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.96 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 10.59 | 3.6746 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 2.23 | 6.7128 | 264.3872 | |
Total | 7836.48 | 23884.04 | 3855.02 | 1150.39 | 4.3335 | 39.48 | 8.6291 | |||
Conditioned Total | 7059.89 | 21517.16 | 3752.84 | 1125.85 | 3.9979 | 35.57 | 6.6700 | |||
Unconditioned Total | 776.58 | 2366.87 | 102.18 | 24.54 | 7.3840 | 26.4387 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:13
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 25-DEC-17:15 | 25-DEC-08:00 | - | - | - | 21-JUL-17:15 |
Heating | 64693.70 | 232623.68 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 11327.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 10364.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 57042.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 23378.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 1814.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 81610.68 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 170607.63 | 314234.36 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | Boiler | 0.00 | 232623.68 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 9220.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 2106.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 10364.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 57042.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 23378.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 1814.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 81610.68 | 0.00 | 0.00 | 0.00 | 0.00 |
sub cat | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:13
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 746.85 | 924.53 | 0.00 | 0.00 | 0.00 |
Cooling | 741.61 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 939.20 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 514.86 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 3601.91 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 2334.93 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 179.43 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 26.71 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 1356.26 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 9200.05 | 2280.78 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 105.79 | 130.95 | 0.00 | 0.00 | 0.00 |
Cooling | 105.04 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 133.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 72.93 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 510.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 330.73 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 25.42 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 3.78 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 192.11 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1303.14 | 323.06 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 105.79 | 130.95 | 0.00 | 0.00 | 0.00 |
Cooling | 105.04 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 133.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 72.93 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 510.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 330.73 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 25.42 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 3.78 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 192.11 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1303.14 | 323.06 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:13
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | -26.30 | 0.00 | -26.30 | Wetbulb [C] | 1.60 | 300.00 |
HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 33.70 | 16.10 | 16.40 | Wetbulb [C] | 4.90 | 290.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:13
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 270.00 | 180.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 270.00 | 180.00 | |
F2 WWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
F2 SWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F2 NWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F2 WWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
F2 EWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
F2 SWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F2 NWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F2 EWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
F2 NWALL N1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F2 NWALL N2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F2 SWALL S1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F2 SWALL S2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F2 WWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 270.00 | 90.00 | W |
F2 EWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 90.00 | 90.00 | E |
F3 WWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
F3 SWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F3 NWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F3 WWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
F3 EWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
F3 SWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F3 NWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F3 EWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
F3 NWALL N1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F3 NWALL N2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F3 SWALL S1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F3 SWALL S2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F3 WWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 270.00 | 90.00 | W |
F3 EWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 90.00 | 90.00 | E |
F4 WWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
F4 SWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F4 NWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F4 WWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
F4 EWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
F4 SWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F4 NWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F4 EWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
F4 NWALL N1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F4 NWALL N2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F4 SWALL S1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F4 SWALL S2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F4 WWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 270.00 | 90.00 | W |
F4 EWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 90.00 | 90.00 | E |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
M WWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 90.00 | 90.00 | E |
F6 WWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
F6 SWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F6 NWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F6 WWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
F6 EWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
F6 SWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F6 NWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F6 EWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
F6 NWALL N1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F6 NWALL N2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F6 SWALL S1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F6 SWALL S2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F6 WWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 270.00 | 90.00 | W |
F6 EWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 90.00 | 90.00 | E |
F7 WWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
F7 SWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F7 NWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F7 WWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
F7 EWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
F7 SWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F7 NWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F7 EWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
F7 NWALL N1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F7 NWALL N2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F7 SWALL S1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F7 SWALL S2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F7 WWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 270.00 | 90.00 | W |
F7 EWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 90.00 | 90.00 | E |
F8 WWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
F8 SWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F8 NWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F8 WWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
F8 EWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
F8 SWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F8 NWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F8 EWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
F8 NWALL N1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F8 NWALL N2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F8 SWALL S1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F8 SWALL S2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F8 WWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 270.00 | 90.00 | W |
F8 EWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 90.00 | 90.00 | E |
F9 WWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
F9 SWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F9 NWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F9 WWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
F9 EWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
F9 SWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F9 NWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F9 EWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
F9 NWALL N1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F9 NWALL N2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
F9 SWALL S1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F9 SWALL S2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
F9 WWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 270.00 | 90.00 | W |
F9 EWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 90.00 | 90.00 | E |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 0.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.30 | 0.269 | 0.283 | 77.66 | 0.00 | 0.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
GWINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | G WWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_0.48_SHGC_0.40 | 3.36 | 0.00 | 0.00 | 3.36 | 3.36 | 2.653 | 0.426 | 0.308 | No | G EWALL C | 90.00 | 90.00 | E | ||
F2WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F2 WWALL SWA | 270.00 | 90.00 | W | ||
F2WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 SWALL SWA | 180.00 | 90.00 | S | ||
F2WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 NWALL NWA | 0.00 | 90.00 | N | ||
F2WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F2 WWALL NWA | 270.00 | 90.00 | W | ||
F2WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F2 EWALL SEA | 90.00 | 90.00 | E | ||
F2WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 SWALL SEA | 180.00 | 90.00 | S | ||
F2WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 NWALL NEA | 0.00 | 90.00 | N | ||
F2WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F2 EWALL NEA | 90.00 | 90.00 | E | ||
F2WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 NWALL N1A | 0.00 | 90.00 | N | ||
F2WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 NWALL N2A | 0.00 | 90.00 | N | ||
F2WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 SWALL S1A | 180.00 | 90.00 | S | ||
F2WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F2 SWALL S2A | 180.00 | 90.00 | S | ||
F2WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F2 WWALL C | 270.00 | 90.00 | W | ||
F2WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F2 EWALL C | 90.00 | 90.00 | E | ||
F3WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F3 WWALL SWA | 270.00 | 90.00 | W | ||
F3WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 SWALL SWA | 180.00 | 90.00 | S | ||
F3WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 NWALL NWA | 0.00 | 90.00 | N | ||
F3WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F3 WWALL NWA | 270.00 | 90.00 | W | ||
F3WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F3 EWALL SEA | 90.00 | 90.00 | E | ||
F3WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 SWALL SEA | 180.00 | 90.00 | S | ||
F3WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 NWALL NEA | 0.00 | 90.00 | N | ||
F3WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F3 EWALL NEA | 90.00 | 90.00 | E | ||
F3WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 NWALL N1A | 0.00 | 90.00 | N | ||
F3WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 NWALL N2A | 0.00 | 90.00 | N | ||
F3WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 SWALL S1A | 180.00 | 90.00 | S | ||
F3WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F3 SWALL S2A | 180.00 | 90.00 | S | ||
F3WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F3 WWALL C | 270.00 | 90.00 | W | ||
F3WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F3 EWALL C | 90.00 | 90.00 | E | ||
F4WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F4 WWALL SWA | 270.00 | 90.00 | W | ||
F4WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 SWALL SWA | 180.00 | 90.00 | S | ||
F4WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 NWALL NWA | 0.00 | 90.00 | N | ||
F4WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F4 WWALL NWA | 270.00 | 90.00 | W | ||
F4WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F4 EWALL SEA | 90.00 | 90.00 | E | ||
F4WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 SWALL SEA | 180.00 | 90.00 | S | ||
F4WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 NWALL NEA | 0.00 | 90.00 | N | ||
F4WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F4 EWALL NEA | 90.00 | 90.00 | E | ||
F4WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 NWALL N1A | 0.00 | 90.00 | N | ||
F4WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 NWALL N2A | 0.00 | 90.00 | N | ||
F4WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 SWALL S1A | 180.00 | 90.00 | S | ||
F4WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F4 SWALL S2A | 180.00 | 90.00 | S | ||
F4WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F4 WWALL C | 270.00 | 90.00 | W | ||
F4WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F4 EWALL C | 90.00 | 90.00 | E | ||
MWINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | M WWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | M EWALL C | 90.00 | 90.00 | E | ||
F6WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F6 WWALL SWA | 270.00 | 90.00 | W | ||
F6WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 SWALL SWA | 180.00 | 90.00 | S | ||
F6WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 NWALL NWA | 0.00 | 90.00 | N | ||
F6WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F6 WWALL NWA | 270.00 | 90.00 | W | ||
F6WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F6 EWALL SEA | 90.00 | 90.00 | E | ||
F6WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 SWALL SEA | 180.00 | 90.00 | S | ||
F6WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 NWALL NEA | 0.00 | 90.00 | N | ||
F6WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F6 EWALL NEA | 90.00 | 90.00 | E | ||
F6WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 NWALL N1A | 0.00 | 90.00 | N | ||
F6WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 NWALL N2A | 0.00 | 90.00 | N | ||
F6WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 SWALL S1A | 180.00 | 90.00 | S | ||
F6WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F6 SWALL S2A | 180.00 | 90.00 | S | ||
F6WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F6 WWALL C | 270.00 | 90.00 | W | ||
F6WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F6 EWALL C | 90.00 | 90.00 | E | ||
F7WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F7 WWALL SWA | 270.00 | 90.00 | W | ||
F7WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 SWALL SWA | 180.00 | 90.00 | S | ||
F7WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 NWALL NWA | 0.00 | 90.00 | N | ||
F7WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F7 WWALL NWA | 270.00 | 90.00 | W | ||
F7WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F7 EWALL SEA | 90.00 | 90.00 | E | ||
F7WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 SWALL SEA | 180.00 | 90.00 | S | ||
F7WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 NWALL NEA | 0.00 | 90.00 | N | ||
F7WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F7 EWALL NEA | 90.00 | 90.00 | E | ||
F7WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 NWALL N1A | 0.00 | 90.00 | N | ||
F7WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 NWALL N2A | 0.00 | 90.00 | N | ||
F7WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 SWALL S1A | 180.00 | 90.00 | S | ||
F7WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F7 SWALL S2A | 180.00 | 90.00 | S | ||
F7WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F7 WWALL C | 270.00 | 90.00 | W | ||
F7WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F7 EWALL C | 90.00 | 90.00 | E | ||
F8WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F8 WWALL SWA | 270.00 | 90.00 | W | ||
F8WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 SWALL SWA | 180.00 | 90.00 | S | ||
F8WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 NWALL NWA | 0.00 | 90.00 | N | ||
F8WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F8 WWALL NWA | 270.00 | 90.00 | W | ||
F8WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F8 EWALL SEA | 90.00 | 90.00 | E | ||
F8WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 SWALL SEA | 180.00 | 90.00 | S | ||
F8WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 NWALL NEA | 0.00 | 90.00 | N | ||
F8WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F8 EWALL NEA | 90.00 | 90.00 | E | ||
F8WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 NWALL N1A | 0.00 | 90.00 | N | ||
F8WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 NWALL N2A | 0.00 | 90.00 | N | ||
F8WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 SWALL S1A | 180.00 | 90.00 | S | ||
F8WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F8 SWALL S2A | 180.00 | 90.00 | S | ||
F8WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F8 WWALL C | 270.00 | 90.00 | W | ||
F8WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F8 EWALL C | 90.00 | 90.00 | E | ||
F9WINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F9 WWALL SWA | 270.00 | 90.00 | W | ||
F9WINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 SWALL SWA | 180.00 | 90.00 | S | ||
F9WINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 NWALL NWA | 0.00 | 90.00 | N | ||
F9WINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F9 WWALL NWA | 270.00 | 90.00 | W | ||
F9WINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F9 EWALL SEA | 90.00 | 90.00 | E | ||
F9WINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 SWALL SEA | 180.00 | 90.00 | S | ||
F9WINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 NWALL NEA | 0.00 | 90.00 | N | ||
F9WINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | F9 EWALL NEA | 90.00 | 90.00 | E | ||
F9WINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 NWALL N1A | 0.00 | 90.00 | N | ||
F9WINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 NWALL N2A | 0.00 | 90.00 | N | ||
F9WINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 SWALL S1A | 180.00 | 90.00 | S | ||
F9WINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | F9 SWALL S2A | 180.00 | 90.00 | S | ||
F9WINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F9 WWALL C | 270.00 | 90.00 | W | ||
F9WINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | F9 EWALL C | 90.00 | 90.00 | E | ||
TWINDOW2 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW3 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW4 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW6 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW8 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW5 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW7 | WINDOW_U_0.48_SHGC_0.40 | 6.97 | 0.00 | 0.00 | 6.97 | 6.97 | 2.653 | 0.426 | 0.308 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW9 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW10 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW11 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW12 | WINDOW_U_0.48_SHGC_0.40 | 10.59 | 0.00 | 0.00 | 10.59 | 10.59 | 2.653 | 0.426 | 0.308 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW13 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | T WWALL C | 270.00 | 90.00 | W | ||
TWINDOW14 | WINDOW_U_0.48_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | T EWALL C | 90.00 | 90.00 | E | ||
Total or Average | 1150.39 | 2.653 | 0.426 | 0.308 | ||||||||||||
North Total or Average | 423.59 | 2.653 | 0.426 | 0.308 | ||||||||||||
Non-North Total or Average | 726.80 | 2.653 | 0.426 | 0.308 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:13
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F2WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F2WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F2WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F3WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F3WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F3WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F4WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F4WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F4WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F6WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F6WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F6WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F7WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F7WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F7WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F8WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F8WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F8WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
F9WINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9WINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
F9WINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
F9WINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW4 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW8 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW5 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW7 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW9 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW11 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW12 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW13 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:13
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
G SW APARTMENT_LIGHTS_HARDWIRED | G SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G NW APARTMENT_LIGHTS_HARDWIRED | G NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
OFFICE_LIGHTS_HARDWIRED | OFFICE | 14.7681 | 88.25 | 1303.26 | GeneralLights | LTG_OFF_SCH | 62.05 | 168.00 | 61.07 | 0.0000 | Y | 14.94 |
G NE APARTMENT_LIGHTS_HARDWIRED | G NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G N1 APARTMENT_LIGHTS_HARDWIRED | G N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G N2 APARTMENT_LIGHTS_HARDWIRED | G N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G S1 APARTMENT_LIGHTS_HARDWIRED | G S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G S2 APARTMENT_LIGHTS_HARDWIRED | G S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
G CORRIDOR_LIGHTS_HARDWIRED | G CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F2 SW APARTMENT_LIGHTS_HARDWIRED | F2 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 NW APARTMENT_LIGHTS_HARDWIRED | F2 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 SE APARTMENT_LIGHTS_HARDWIRED | F2 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 NE APARTMENT_LIGHTS_HARDWIRED | F2 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 N1 APARTMENT_LIGHTS_HARDWIRED | F2 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 N2 APARTMENT_LIGHTS_HARDWIRED | F2 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 S1 APARTMENT_LIGHTS_HARDWIRED | F2 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 S2 APARTMENT_LIGHTS_HARDWIRED | F2 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F2 CORRIDOR_LIGHTS_HARDWIRED | F2 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F3 SW APARTMENT_LIGHTS_HARDWIRED | F3 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 NW APARTMENT_LIGHTS_HARDWIRED | F3 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 SE APARTMENT_LIGHTS_HARDWIRED | F3 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 NE APARTMENT_LIGHTS_HARDWIRED | F3 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 N1 APARTMENT_LIGHTS_HARDWIRED | F3 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 N2 APARTMENT_LIGHTS_HARDWIRED | F3 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 S1 APARTMENT_LIGHTS_HARDWIRED | F3 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 S2 APARTMENT_LIGHTS_HARDWIRED | F3 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F3 CORRIDOR_LIGHTS_HARDWIRED | F3 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F4 SW APARTMENT_LIGHTS_HARDWIRED | F4 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 NW APARTMENT_LIGHTS_HARDWIRED | F4 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 SE APARTMENT_LIGHTS_HARDWIRED | F4 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 NE APARTMENT_LIGHTS_HARDWIRED | F4 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 N1 APARTMENT_LIGHTS_HARDWIRED | F4 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 N2 APARTMENT_LIGHTS_HARDWIRED | F4 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 S1 APARTMENT_LIGHTS_HARDWIRED | F4 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 S2 APARTMENT_LIGHTS_HARDWIRED | F4 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F4 CORRIDOR_LIGHTS_HARDWIRED | F4 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
M SW APARTMENT_LIGHTS_HARDWIRED | M SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M NW APARTMENT_LIGHTS_HARDWIRED | M NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M SE APARTMENT_LIGHTS_HARDWIRED | M SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M NE APARTMENT_LIGHTS_HARDWIRED | M NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M N1 APARTMENT_LIGHTS_HARDWIRED | M N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M N2 APARTMENT_LIGHTS_HARDWIRED | M N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M S1 APARTMENT_LIGHTS_HARDWIRED | M S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M S2 APARTMENT_LIGHTS_HARDWIRED | M S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
M CORRIDOR_LIGHTS_HARDWIRED | M CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F6 SW APARTMENT_LIGHTS_HARDWIRED | F6 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 NW APARTMENT_LIGHTS_HARDWIRED | F6 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 SE APARTMENT_LIGHTS_HARDWIRED | F6 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 NE APARTMENT_LIGHTS_HARDWIRED | F6 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 N1 APARTMENT_LIGHTS_HARDWIRED | F6 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 N2 APARTMENT_LIGHTS_HARDWIRED | F6 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 S1 APARTMENT_LIGHTS_HARDWIRED | F6 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 S2 APARTMENT_LIGHTS_HARDWIRED | F6 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F6 CORRIDOR_LIGHTS_HARDWIRED | F6 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F7 SW APARTMENT_LIGHTS_HARDWIRED | F7 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 NW APARTMENT_LIGHTS_HARDWIRED | F7 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 SE APARTMENT_LIGHTS_HARDWIRED | F7 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 NE APARTMENT_LIGHTS_HARDWIRED | F7 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 N1 APARTMENT_LIGHTS_HARDWIRED | F7 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 N2 APARTMENT_LIGHTS_HARDWIRED | F7 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 S1 APARTMENT_LIGHTS_HARDWIRED | F7 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 S2 APARTMENT_LIGHTS_HARDWIRED | F7 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F7 CORRIDOR_LIGHTS_HARDWIRED | F7 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F8 SW APARTMENT_LIGHTS_HARDWIRED | F8 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 NW APARTMENT_LIGHTS_HARDWIRED | F8 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 SE APARTMENT_LIGHTS_HARDWIRED | F8 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 NE APARTMENT_LIGHTS_HARDWIRED | F8 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 N1 APARTMENT_LIGHTS_HARDWIRED | F8 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 N2 APARTMENT_LIGHTS_HARDWIRED | F8 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 S1 APARTMENT_LIGHTS_HARDWIRED | F8 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 S2 APARTMENT_LIGHTS_HARDWIRED | F8 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F8 CORRIDOR_LIGHTS_HARDWIRED | F8 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F9 SW APARTMENT_LIGHTS_HARDWIRED | F9 SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 NW APARTMENT_LIGHTS_HARDWIRED | F9 NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 SE APARTMENT_LIGHTS_HARDWIRED | F9 SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 NE APARTMENT_LIGHTS_HARDWIRED | F9 NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 N1 APARTMENT_LIGHTS_HARDWIRED | F9 N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 N2 APARTMENT_LIGHTS_HARDWIRED | F9 N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 S1 APARTMENT_LIGHTS_HARDWIRED | F9 S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 S2 APARTMENT_LIGHTS_HARDWIRED | F9 S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
F9 CORRIDOR_LIGHTS_HARDWIRED | F9 CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
T SW APARTMENT_LIGHTS_HARDWIRED | T SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T NW APARTMENT_LIGHTS_HARDWIRED | T NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T SE APARTMENT_LIGHTS_HARDWIRED | T SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T NE APARTMENT_LIGHTS_HARDWIRED | T NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T N1 APARTMENT_LIGHTS_HARDWIRED | T N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T N2 APARTMENT_LIGHTS_HARDWIRED | T N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T S1 APARTMENT_LIGHTS_HARDWIRED | T S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T S2 APARTMENT_LIGHTS_HARDWIRED | T S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
T CORRIDOR_LIGHTS_HARDWIRED | T CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
G SW APARTMENT_LIGHTS_PLUGIN | G SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G NW APARTMENT_LIGHTS_PLUGIN | G NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
OFFICE_LIGHTS_PLUGIN | OFFICE | 14.7681 | 88.25 | 1303.26 | GeneralLights-plugin | LTG_OFF_SCH | 62.05 | 168.00 | 61.07 | 0.0000 | Y | 14.94 |
G NE APARTMENT_LIGHTS_PLUGIN | G NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G N1 APARTMENT_LIGHTS_PLUGIN | G N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G N2 APARTMENT_LIGHTS_PLUGIN | G N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G S1 APARTMENT_LIGHTS_PLUGIN | G S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
G S2 APARTMENT_LIGHTS_PLUGIN | G S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 SW APARTMENT_LIGHTS_PLUGIN | F2 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 NW APARTMENT_LIGHTS_PLUGIN | F2 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 SE APARTMENT_LIGHTS_PLUGIN | F2 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 NE APARTMENT_LIGHTS_PLUGIN | F2 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 N1 APARTMENT_LIGHTS_PLUGIN | F2 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 N2 APARTMENT_LIGHTS_PLUGIN | F2 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 S1 APARTMENT_LIGHTS_PLUGIN | F2 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F2 S2 APARTMENT_LIGHTS_PLUGIN | F2 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 SW APARTMENT_LIGHTS_PLUGIN | F3 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 NW APARTMENT_LIGHTS_PLUGIN | F3 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 SE APARTMENT_LIGHTS_PLUGIN | F3 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 NE APARTMENT_LIGHTS_PLUGIN | F3 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 N1 APARTMENT_LIGHTS_PLUGIN | F3 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 N2 APARTMENT_LIGHTS_PLUGIN | F3 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 S1 APARTMENT_LIGHTS_PLUGIN | F3 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F3 S2 APARTMENT_LIGHTS_PLUGIN | F3 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 SW APARTMENT_LIGHTS_PLUGIN | F4 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 NW APARTMENT_LIGHTS_PLUGIN | F4 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 SE APARTMENT_LIGHTS_PLUGIN | F4 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 NE APARTMENT_LIGHTS_PLUGIN | F4 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 N1 APARTMENT_LIGHTS_PLUGIN | F4 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 N2 APARTMENT_LIGHTS_PLUGIN | F4 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 S1 APARTMENT_LIGHTS_PLUGIN | F4 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F4 S2 APARTMENT_LIGHTS_PLUGIN | F4 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M SW APARTMENT_LIGHTS_PLUGIN | M SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M NW APARTMENT_LIGHTS_PLUGIN | M NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M SE APARTMENT_LIGHTS_PLUGIN | M SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M NE APARTMENT_LIGHTS_PLUGIN | M NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M N1 APARTMENT_LIGHTS_PLUGIN | M N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M N2 APARTMENT_LIGHTS_PLUGIN | M N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M S1 APARTMENT_LIGHTS_PLUGIN | M S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M S2 APARTMENT_LIGHTS_PLUGIN | M S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
M CORRIDOR_LIGHTS_PLUGIN | M CORRIDOR | 6.7128 | 77.66 | 521.30 | GeneralLights-plugin | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 16.44 |
F6 SW APARTMENT_LIGHTS_PLUGIN | F6 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 NW APARTMENT_LIGHTS_PLUGIN | F6 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 SE APARTMENT_LIGHTS_PLUGIN | F6 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 NE APARTMENT_LIGHTS_PLUGIN | F6 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 N1 APARTMENT_LIGHTS_PLUGIN | F6 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 N2 APARTMENT_LIGHTS_PLUGIN | F6 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 S1 APARTMENT_LIGHTS_PLUGIN | F6 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F6 S2 APARTMENT_LIGHTS_PLUGIN | F6 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 SW APARTMENT_LIGHTS_PLUGIN | F7 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 NW APARTMENT_LIGHTS_PLUGIN | F7 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 SE APARTMENT_LIGHTS_PLUGIN | F7 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 NE APARTMENT_LIGHTS_PLUGIN | F7 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 N1 APARTMENT_LIGHTS_PLUGIN | F7 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 N2 APARTMENT_LIGHTS_PLUGIN | F7 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 S1 APARTMENT_LIGHTS_PLUGIN | F7 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F7 S2 APARTMENT_LIGHTS_PLUGIN | F7 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 SW APARTMENT_LIGHTS_PLUGIN | F8 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 NW APARTMENT_LIGHTS_PLUGIN | F8 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 SE APARTMENT_LIGHTS_PLUGIN | F8 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 NE APARTMENT_LIGHTS_PLUGIN | F8 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 N1 APARTMENT_LIGHTS_PLUGIN | F8 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 N2 APARTMENT_LIGHTS_PLUGIN | F8 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 S1 APARTMENT_LIGHTS_PLUGIN | F8 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F8 S2 APARTMENT_LIGHTS_PLUGIN | F8 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 SW APARTMENT_LIGHTS_PLUGIN | F9 SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 NW APARTMENT_LIGHTS_PLUGIN | F9 NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 SE APARTMENT_LIGHTS_PLUGIN | F9 SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 NE APARTMENT_LIGHTS_PLUGIN | F9 NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 N1 APARTMENT_LIGHTS_PLUGIN | F9 N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 N2 APARTMENT_LIGHTS_PLUGIN | F9 N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 S1 APARTMENT_LIGHTS_PLUGIN | F9 S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
F9 S2 APARTMENT_LIGHTS_PLUGIN | F9 S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T SW APARTMENT_LIGHTS_PLUGIN | T SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T NW APARTMENT_LIGHTS_PLUGIN | T NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T SE APARTMENT_LIGHTS_PLUGIN | T SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T NE APARTMENT_LIGHTS_PLUGIN | T NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T N1 APARTMENT_LIGHTS_PLUGIN | T N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T N2 APARTMENT_LIGHTS_PLUGIN | T N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T S1 APARTMENT_LIGHTS_PLUGIN | T S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
T S2 APARTMENT_LIGHTS_PLUGIN | T S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
Interior Lighting Total | 2.2679 | 14974.03 | 33959.19 | 296.56 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 10364.00 | AstronomicalClock | - | 83.56 | 83.56 | 162.57 | |
Exterior Lighting Total | 10364.00 | 162.57 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:13
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
CENTRAL BOILER | Boiler:HotWater | 255907.94 | 0.75 | ||
CENTRAL TOWER | EvaporativeFluidCooler:SingleSpeed | 204726.35 |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
HEAT PUMP COOLING MODE AIRLOOP G SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3320.88 | 2262.96 | 1057.93 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2936.09 | 2014.22 | 921.87 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP OFFICE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5108.72 | 3463.07 | 1645.65 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2103.58 | 1461.41 | 642.16 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 1439.44 | 1005.49 | 433.95 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 1438.70 | 1005.78 | 432.92 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2215.71 | 1493.70 | 722.01 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP G S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2309.38 | 1557.11 | 752.27 | 0.67 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4269.83 | 2921.78 | 1348.05 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3781.51 | 2596.83 | 1184.68 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4282.48 | 2914.93 | 1367.55 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2777.62 | 1928.66 | 848.97 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 1899.41 | 1318.87 | 580.53 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 1877.81 | 1304.36 | 573.45 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2914.54 | 1973.91 | 940.63 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F2 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2949.27 | 1997.36 | 951.91 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4299.74 | 2948.82 | 1350.92 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3815.75 | 2628.07 | 1187.67 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4033.67 | 2755.04 | 1278.63 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2828.81 | 1970.89 | 857.92 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 1952.00 | 1358.72 | 593.28 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 1930.53 | 1344.28 | 586.25 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2979.77 | 2022.77 | 957.00 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F3 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2996.02 | 2033.74 | 962.28 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4314.11 | 2964.63 | 1349.48 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3828.44 | 2642.70 | 1185.73 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4033.64 | 2760.98 | 1272.66 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2858.20 | 1992.04 | 866.16 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 1969.49 | 1373.86 | 595.64 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 1948.14 | 1359.48 | 588.66 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3005.23 | 2043.56 | 961.67 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F4 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3018.83 | 2052.75 | 966.08 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4383.03 | 3012.36 | 1370.68 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3866.61 | 2673.36 | 1193.24 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4081.51 | 2798.17 | 1283.34 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2896.83 | 2022.74 | 874.09 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2009.16 | 1403.25 | 605.91 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 1987.90 | 1388.93 | 598.98 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3051.65 | 2077.87 | 973.78 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP M S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3064.86 | 2086.79 | 978.08 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4344.62 | 2990.62 | 1354.00 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3821.36 | 2647.03 | 1174.33 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4049.74 | 2780.79 | 1268.95 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2854.67 | 1997.99 | 856.69 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 1969.05 | 1378.61 | 590.44 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 1948.00 | 1364.41 | 583.59 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3016.26 | 2056.42 | 959.84 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F6 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3029.43 | 2065.32 | 964.11 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4335.21 | 2987.94 | 1347.27 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3818.90 | 2647.25 | 1171.65 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4046.06 | 2781.89 | 1264.17 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2842.05 | 1992.75 | 849.30 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 1957.70 | 1372.98 | 584.72 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 1936.80 | 1358.87 | 577.93 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3008.89 | 2053.62 | 955.28 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F7 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3022.05 | 2062.50 | 959.55 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4341.23 | 2995.30 | 1345.93 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3822.55 | 2652.96 | 1169.60 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4056.66 | 2792.27 | 1264.39 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2844.57 | 1997.42 | 847.15 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 1963.02 | 1378.36 | 584.66 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 1942.29 | 1364.36 | 577.94 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3016.46 | 2060.68 | 955.78 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F8 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3029.64 | 2069.59 | 960.05 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4455.68 | 3075.68 | 1380.00 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3929.50 | 2729.94 | 1199.56 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4148.48 | 2857.18 | 1291.29 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2881.51 | 2025.24 | 856.27 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2068.13 | 1450.83 | 617.31 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2047.26 | 1436.72 | 610.53 | 0.70 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3091.81 | 2113.49 | 978.32 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP F9 S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3106.64 | 2123.51 | 983.13 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T SW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5539.38 | 3805.10 | 1734.29 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T NW | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4796.19 | 3313.16 | 1483.03 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T SE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 5089.00 | 3496.10 | 1592.90 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T NE | Coil:Cooling:WaterToAirHeatPump:EquationFit | 3731.28 | 2577.25 | 1154.03 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T N1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2867.91 | 1965.11 | 902.80 | 0.69 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T N2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 2871.19 | 1965.59 | 905.60 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T S1 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4186.84 | 2855.17 | 1331.67 | 0.68 | 0.00 | |||
HEAT PUMP COOLING MODE AIRLOOP T S2 | Coil:Cooling:WaterToAirHeatPump:EquationFit | 4201.01 | 2864.86 | 1336.15 | 0.68 | 0.00 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
None |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
HEAT PUMP HEATING MODE AIRLOOP G SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 3320.88 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 2936.09 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP OFFICE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5108.72 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 2103.58 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 1439.44 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 1438.70 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2215.71 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP G S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2309.38 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4269.83 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 3781.51 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4282.48 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 2777.62 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 1899.41 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 1877.81 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2914.54 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F2 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2949.27 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4299.74 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 3815.75 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4033.67 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 2828.81 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 1952.00 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 1930.53 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2979.77 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F3 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2996.02 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4314.11 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 3828.44 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4033.64 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 2858.20 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 1969.49 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 1948.14 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3005.23 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F4 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3018.83 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4383.03 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 3866.61 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4081.51 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 2896.83 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2009.16 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 1987.90 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3051.65 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP M S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3064.86 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4344.62 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 3821.36 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4049.74 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 2854.67 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 1969.05 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 1948.00 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3016.26 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F6 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3029.43 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4335.21 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 3818.90 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4046.06 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 2842.05 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 1957.70 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 1936.80 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3008.89 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F7 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3022.05 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4341.23 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 3822.55 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4056.66 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 2844.57 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 1963.02 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 1942.29 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3016.46 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F8 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3029.64 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4455.68 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 3929.50 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 4148.48 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 2881.51 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2068.13 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2047.26 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3091.81 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP F9 S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 3106.64 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T SW | Coil:Heating:WaterToAirHeatPump:EquationFit | 5539.38 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T NW | Coil:Heating:WaterToAirHeatPump:EquationFit | 4796.19 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T SE | Coil:Heating:WaterToAirHeatPump:EquationFit | 5089.00 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T NE | Coil:Heating:WaterToAirHeatPump:EquationFit | 3731.28 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T N1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2867.91 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T N2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 2871.19 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T S1 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4186.84 | 0.00 | |
HEAT PUMP HEATING MODE AIRLOOP T S2 | Coil:Heating:WaterToAirHeatPump:EquationFit | 4201.01 | 0.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW | Coil:Heating:Electric | 4530.04 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW | Coil:Heating:Electric | 4530.57 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE | Coil:Heating:Electric | 5570.62 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE | Coil:Heating:Electric | 4536.36 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 | Coil:Heating:Electric | 3542.17 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 | Coil:Heating:Electric | 3542.30 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 | Coil:Heating:Electric | 3539.28 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 | Coil:Heating:Electric | 3545.68 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW | Coil:Heating:Electric | 4219.43 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW | Coil:Heating:Electric | 4207.11 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE | Coil:Heating:Electric | 4244.62 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE | Coil:Heating:Electric | 4214.24 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 | Coil:Heating:Electric | 3017.74 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 | Coil:Heating:Electric | 3017.90 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 | Coil:Heating:Electric | 3033.24 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 | Coil:Heating:Electric | 3034.50 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW | Coil:Heating:Electric | 4172.14 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW | Coil:Heating:Electric | 4162.51 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE | Coil:Heating:Electric | 4180.94 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE | Coil:Heating:Electric | 4169.50 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 | Coil:Heating:Electric | 2934.43 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 | Coil:Heating:Electric | 2934.59 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 | Coil:Heating:Electric | 2945.29 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 | Coil:Heating:Electric | 2945.60 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW | Coil:Heating:Electric | 4220.93 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW | Coil:Heating:Electric | 4212.63 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE | Coil:Heating:Electric | 4227.77 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE | Coil:Heating:Electric | 4219.30 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 | Coil:Heating:Electric | 2950.96 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 | Coil:Heating:Electric | 2951.11 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 | Coil:Heating:Electric | 2960.20 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 | Coil:Heating:Electric | 2960.38 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW | Coil:Heating:Electric | 4254.28 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW | Coil:Heating:Electric | 4245.79 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE | Coil:Heating:Electric | 4260.57 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE | Coil:Heating:Electric | 4252.06 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 | Coil:Heating:Electric | 2957.31 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 | Coil:Heating:Electric | 2957.46 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 | Coil:Heating:Electric | 2966.72 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 | Coil:Heating:Electric | 2966.87 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW | Coil:Heating:Electric | 4347.20 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW | Coil:Heating:Electric | 4340.24 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE | Coil:Heating:Electric | 4353.07 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE | Coil:Heating:Electric | 4346.11 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 | Coil:Heating:Electric | 3027.75 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 | Coil:Heating:Electric | 3027.88 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 | Coil:Heating:Electric | 3035.61 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 | Coil:Heating:Electric | 3035.74 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW | Coil:Heating:Electric | 4412.86 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW | Coil:Heating:Electric | 4406.32 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE | Coil:Heating:Electric | 4418.31 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE | Coil:Heating:Electric | 4411.77 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 | Coil:Heating:Electric | 3073.46 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 | Coil:Heating:Electric | 3073.59 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 | Coil:Heating:Electric | 3080.91 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 | Coil:Heating:Electric | 3081.04 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW | Coil:Heating:Electric | 4487.91 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW | Coil:Heating:Electric | 4481.41 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE | Coil:Heating:Electric | 4492.95 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE | Coil:Heating:Electric | 4486.45 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 | Coil:Heating:Electric | 3130.61 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 | Coil:Heating:Electric | 3130.72 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 | Coil:Heating:Electric | 3138.02 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 | Coil:Heating:Electric | 3138.13 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW | Coil:Heating:Electric | 4745.45 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW | Coil:Heating:Electric | 4735.53 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE | Coil:Heating:Electric | 4750.14 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE | Coil:Heating:Electric | 4740.22 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 | Coil:Heating:Electric | 3357.19 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 | Coil:Heating:Electric | 3357.30 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 | Coil:Heating:Electric | 3367.58 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 | Coil:Heating:Electric | 3367.69 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW | Coil:Heating:Electric | 5755.41 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW | Coil:Heating:Electric | 5755.65 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE | Coil:Heating:Electric | 5759.44 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE | Coil:Heating:Electric | 5759.68 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 | Coil:Heating:Electric | 4435.53 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 | Coil:Heating:Electric | 4435.63 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 | Coil:Heating:Electric | 4432.80 | 1.00 | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 | Coil:Heating:Electric | 4432.90 | 1.00 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
AIRLOOP G SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.26 | 299.40 | 1160.84 | 1.00 | General |
AIRLOOP G NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 269.63 | 1160.84 | 1.00 | General |
AIRLOOP OFFICE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.39 | 455.00 | 1160.84 | 1.00 | General |
AIRLOOP G NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 194.55 | 1160.84 | 1.00 | General |
AIRLOOP G N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.12 | 134.60 | 1160.84 | 1.00 | General |
AIRLOOP G N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.12 | 134.61 | 1160.84 | 1.00 | General |
AIRLOOP G S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 192.02 | 1160.84 | 1.00 | General |
AIRLOOP G S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 200.61 | 1160.84 | 1.00 | General |
AIRLOOP F2 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.34 | 392.18 | 1160.84 | 1.00 | General |
AIRLOOP F2 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 349.50 | 1160.84 | 1.00 | General |
AIRLOOP F2 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 386.20 | 1160.84 | 1.00 | General |
AIRLOOP F2 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 258.93 | 1160.84 | 1.00 | General |
AIRLOOP F2 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 177.55 | 1160.84 | 1.00 | General |
AIRLOOP F2 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 175.58 | 1160.84 | 1.00 | General |
AIRLOOP F2 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 257.51 | 1160.84 | 1.00 | General |
AIRLOOP F2 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 260.69 | 1160.84 | 1.00 | General |
AIRLOOP F3 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.34 | 395.73 | 1160.84 | 1.00 | General |
AIRLOOP F3 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 354.18 | 1160.84 | 1.00 | General |
AIRLOOP F3 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 364.91 | 1160.84 | 1.00 | General |
AIRLOOP F3 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 265.08 | 1160.84 | 1.00 | General |
AIRLOOP F3 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 183.20 | 1160.84 | 1.00 | General |
AIRLOOP F3 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 181.24 | 1160.84 | 1.00 | General |
AIRLOOP F3 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 264.40 | 1160.84 | 1.00 | General |
AIRLOOP F3 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 265.89 | 1160.84 | 1.00 | General |
AIRLOOP F4 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.34 | 398.20 | 1160.84 | 1.00 | General |
AIRLOOP F4 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 356.49 | 1160.84 | 1.00 | General |
AIRLOOP F4 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 366.04 | 1160.84 | 1.00 | General |
AIRLOOP F4 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 267.28 | 1160.84 | 1.00 | General |
AIRLOOP F4 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 185.43 | 1160.84 | 1.00 | General |
AIRLOOP F4 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 183.48 | 1160.84 | 1.00 | General |
AIRLOOP F4 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 267.41 | 1160.84 | 1.00 | General |
AIRLOOP F4 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 268.66 | 1160.84 | 1.00 | General |
AIRLOOP M SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.35 | 402.96 | 1160.84 | 1.00 | General |
AIRLOOP M NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 360.92 | 1160.84 | 1.00 | General |
AIRLOOP M SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 371.35 | 1160.84 | 1.00 | General |
AIRLOOP M NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 271.70 | 1160.84 | 1.00 | General |
AIRLOOP M N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 189.57 | 1160.84 | 1.00 | General |
AIRLOOP M N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 187.62 | 1160.84 | 1.00 | General |
AIRLOOP M S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 272.22 | 1160.84 | 1.00 | General |
AIRLOOP M S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 273.43 | 1160.84 | 1.00 | General |
AIRLOOP F6 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.34 | 400.23 | 1160.84 | 1.00 | General |
AIRLOOP F6 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 357.56 | 1160.84 | 1.00 | General |
AIRLOOP F6 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 369.20 | 1160.84 | 1.00 | General |
AIRLOOP F6 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 268.52 | 1160.84 | 1.00 | General |
AIRLOOP F6 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 186.34 | 1160.84 | 1.00 | General |
AIRLOOP F6 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 184.41 | 1160.84 | 1.00 | General |
AIRLOOP F6 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 269.44 | 1160.84 | 1.00 | General |
AIRLOOP F6 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 270.65 | 1160.84 | 1.00 | General |
AIRLOOP F7 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.34 | 400.06 | 1160.84 | 1.00 | General |
AIRLOOP F7 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 356.93 | 1160.84 | 1.00 | General |
AIRLOOP F7 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 369.54 | 1160.84 | 1.00 | General |
AIRLOOP F7 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 267.98 | 1160.84 | 1.00 | General |
AIRLOOP F7 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 185.68 | 1160.84 | 1.00 | General |
AIRLOOP F7 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 183.76 | 1160.84 | 1.00 | General |
AIRLOOP F7 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 269.18 | 1160.84 | 1.00 | General |
AIRLOOP F7 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 270.38 | 1160.84 | 1.00 | General |
AIRLOOP F8 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.35 | 401.23 | 1160.84 | 1.00 | General |
AIRLOOP F8 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 357.88 | 1160.84 | 1.00 | General |
AIRLOOP F8 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 371.12 | 1160.84 | 1.00 | General |
AIRLOOP F8 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 268.77 | 1160.84 | 1.00 | General |
AIRLOOP F8 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 186.50 | 1160.84 | 1.00 | General |
AIRLOOP F8 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 184.60 | 1160.84 | 1.00 | General |
AIRLOOP F8 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 270.24 | 1160.84 | 1.00 | General |
AIRLOOP F8 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 271.45 | 1160.84 | 1.00 | General |
AIRLOOP F9 SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.36 | 412.33 | 1160.84 | 1.00 | General |
AIRLOOP F9 NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 369.35 | 1160.84 | 1.00 | General |
AIRLOOP F9 SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 380.10 | 1160.84 | 1.00 | General |
AIRLOOP F9 NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.23 | 272.70 | 1160.84 | 1.00 | General |
AIRLOOP F9 N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 196.44 | 1160.84 | 1.00 | General |
AIRLOOP F9 N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 194.52 | 1160.84 | 1.00 | General |
AIRLOOP F9 S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 277.51 | 1160.84 | 1.00 | General |
AIRLOOP F9 S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 278.87 | 1160.84 | 1.00 | General |
AIRLOOP T SW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.44 | 510.30 | 1160.84 | 1.00 | General |
AIRLOOP T NW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.38 | 446.32 | 1160.84 | 1.00 | General |
AIRLOOP T SE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.40 | 467.14 | 1160.84 | 1.00 | General |
AIRLOOP T NE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.29 | 342.16 | 1160.84 | 1.00 | General |
AIRLOOP T N1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 257.80 | 1160.84 | 1.00 | General |
AIRLOOP T N2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 257.50 | 1160.84 | 1.00 | General |
AIRLOOP T S1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 378.34 | 1160.84 | 1.00 | General |
AIRLOOP T S2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 379.66 | 1160.84 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
SHWSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.0003 | 36.93 | 127739.32 | 0.30 |
PLANT CIRC PUMP | Pump:ConstantSpeed | Intermittent | 224180.02 | 0.0056 | 1777.54 | 319344.75 | 0.90 |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SHWSYS1 WATER HEATER | WaterHeater:Mixed | 2.27 | 175842.64 | 0.80 | 0.00 | 0.00 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:13
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 2385.97 | 2863.17 | 0.215 | 0.258 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 32.09 | 0.00635 |
G NW APARTMENT | 2148.73 | 2578.48 | 0.194 | 0.232 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 29.23 | 0.00635 |
OFFICE | 3626.00 | 4351.20 | 0.327 | 0.392 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 33.70 | 0.00635 |
G NE APARTMENT | 1491.46 | 1789.76 | 0.134 | 0.161 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 29.39 | 0.00635 |
G N1 APARTMENT | 1018.33 | 1222.00 | 0.092 | 0.110 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
G N2 APARTMENT | 999.11 | 1198.93 | 0.090 | 0.108 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
G S1 APARTMENT | 1530.20 | 1836.24 | 0.138 | 0.165 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
G S2 APARTMENT | 1598.63 | 1918.36 | 0.144 | 0.173 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 33.70 | 0.00635 |
F2 SW APARTMENT | 3125.38 | 3750.45 | 0.282 | 0.338 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 30.24 | 0.00635 |
F2 NW APARTMENT | 2785.19 | 3342.22 | 0.251 | 0.301 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 29.23 | 0.00635 |
F2 SE APARTMENT | 3077.76 | 3693.31 | 0.277 | 0.333 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 33.70 | 0.00635 |
F2 NE APARTMENT | 2063.49 | 2476.19 | 0.186 | 0.223 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 29.39 | 0.00635 |
F2 N1 APARTMENT | 1414.91 | 1697.89 | 0.127 | 0.153 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
F2 N2 APARTMENT | 1399.21 | 1679.05 | 0.126 | 0.151 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
F2 S1 APARTMENT | 2052.16 | 2462.59 | 0.185 | 0.222 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
F2 S2 APARTMENT | 2077.50 | 2493.00 | 0.187 | 0.225 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
F3 SW APARTMENT | 3153.62 | 3784.35 | 0.284 | 0.341 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 30.64 | 0.00635 |
F3 NW APARTMENT | 2822.50 | 3387.00 | 0.254 | 0.305 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 29.23 | 0.00635 |
F3 SE APARTMENT | 2908.11 | 3489.73 | 0.262 | 0.314 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 33.70 | 0.00635 |
F3 NE APARTMENT | 2112.47 | 2534.97 | 0.190 | 0.228 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 29.39 | 0.00635 |
F3 N1 APARTMENT | 1459.92 | 1751.90 | 0.132 | 0.158 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
F3 N2 APARTMENT | 1444.28 | 1733.14 | 0.130 | 0.156 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
F3 S1 APARTMENT | 2107.03 | 2528.44 | 0.190 | 0.228 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
F3 S2 APARTMENT | 2118.89 | 2542.66 | 0.191 | 0.229 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
F4 SW APARTMENT | 3173.35 | 3808.02 | 0.286 | 0.343 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 30.64 | 0.00635 |
F4 NW APARTMENT | 2840.93 | 3409.11 | 0.256 | 0.307 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 29.23 | 0.00635 |
F4 SE APARTMENT | 2917.08 | 3500.49 | 0.263 | 0.315 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 33.70 | 0.00635 |
F4 NE APARTMENT | 2130.07 | 2556.08 | 0.192 | 0.230 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 30.00 | 0.00635 |
F4 N1 APARTMENT | 1477.71 | 1773.25 | 0.133 | 0.160 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
F4 N2 APARTMENT | 1462.13 | 1754.56 | 0.132 | 0.158 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
F4 S1 APARTMENT | 2131.05 | 2557.26 | 0.192 | 0.230 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
F4 S2 APARTMENT | 2140.98 | 2569.17 | 0.193 | 0.231 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
M SW APARTMENT | 3211.37 | 3853.65 | 0.289 | 0.347 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 32.09 | 0.00635 |
M NW APARTMENT | 2876.22 | 3451.47 | 0.259 | 0.311 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 29.23 | 0.00635 |
M SE APARTMENT | 2959.42 | 3551.30 | 0.267 | 0.320 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 33.70 | 0.00635 |
M NE APARTMENT | 2165.26 | 2598.31 | 0.195 | 0.234 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 30.00 | 0.00635 |
M N1 APARTMENT | 1510.66 | 1812.79 | 0.136 | 0.163 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
M N2 APARTMENT | 1495.14 | 1794.17 | 0.135 | 0.162 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
M S1 APARTMENT | 2169.40 | 2603.28 | 0.195 | 0.235 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
M S2 APARTMENT | 2179.04 | 2614.85 | 0.196 | 0.236 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
F6 SW APARTMENT | 3189.61 | 3827.53 | 0.287 | 0.345 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 32.09 | 0.00635 |
F6 NW APARTMENT | 2849.45 | 3419.34 | 0.257 | 0.308 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 29.23 | 0.00635 |
F6 SE APARTMENT | 2942.33 | 3530.80 | 0.265 | 0.318 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 33.70 | 0.00635 |
F6 NE APARTMENT | 2139.98 | 2567.97 | 0.193 | 0.231 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 30.00 | 0.00635 |
F6 N1 APARTMENT | 1484.95 | 1781.94 | 0.134 | 0.161 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
F6 N2 APARTMENT | 1469.57 | 1763.48 | 0.132 | 0.159 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
F6 S1 APARTMENT | 2147.26 | 2576.71 | 0.193 | 0.232 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
F6 S2 APARTMENT | 2156.88 | 2588.25 | 0.194 | 0.233 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
F7 SW APARTMENT | 3188.26 | 3825.91 | 0.287 | 0.345 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 32.09 | 0.00635 |
F7 NW APARTMENT | 2844.46 | 3413.36 | 0.256 | 0.307 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 29.84 | 0.00635 |
F7 SE APARTMENT | 2945.04 | 3534.04 | 0.265 | 0.318 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 33.70 | 0.00635 |
F7 NE APARTMENT | 2135.66 | 2562.80 | 0.192 | 0.231 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 30.00 | 0.00635 |
F7 N1 APARTMENT | 1479.70 | 1775.64 | 0.133 | 0.160 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
F7 N2 APARTMENT | 1464.41 | 1757.29 | 0.132 | 0.158 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
F7 S1 APARTMENT | 2145.15 | 2574.18 | 0.193 | 0.232 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
F7 S2 APARTMENT | 2154.76 | 2585.71 | 0.194 | 0.233 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
F8 SW APARTMENT | 3197.62 | 3837.14 | 0.288 | 0.346 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 32.09 | 0.00635 |
F8 NW APARTMENT | 2852.01 | 3422.42 | 0.257 | 0.308 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 29.84 | 0.00635 |
F8 SE APARTMENT | 2957.64 | 3549.16 | 0.266 | 0.320 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 33.70 | 0.00635 |
F8 NE APARTMENT | 2141.96 | 2570.35 | 0.193 | 0.232 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 30.00 | 0.00635 |
F8 N1 APARTMENT | 1486.27 | 1783.52 | 0.134 | 0.161 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
F8 N2 APARTMENT | 1471.08 | 1765.30 | 0.133 | 0.159 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
F8 S1 APARTMENT | 2153.62 | 2584.34 | 0.194 | 0.233 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
F8 S2 APARTMENT | 2163.25 | 2595.90 | 0.195 | 0.234 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
F9 SW APARTMENT | 3286.03 | 3943.24 | 0.296 | 0.355 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 32.09 | 0.00635 |
F9 NW APARTMENT | 2943.49 | 3532.18 | 0.265 | 0.318 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 29.23 | 0.00635 |
F9 SE APARTMENT | 3029.16 | 3635.00 | 0.273 | 0.327 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
F9 NE APARTMENT | 2173.29 | 2607.95 | 0.196 | 0.235 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 30.00 | 0.00635 |
F9 N1 APARTMENT | 1565.46 | 1878.55 | 0.141 | 0.169 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
F9 N2 APARTMENT | 1550.16 | 1860.19 | 0.140 | 0.168 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
F9 S1 APARTMENT | 2211.54 | 2653.85 | 0.199 | 0.239 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
F9 S2 APARTMENT | 2222.38 | 2666.85 | 0.200 | 0.240 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
T SW APARTMENT | 4066.86 | 4880.23 | 0.366 | 0.440 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:45:00 | 32.98 | 0.00635 |
T NW APARTMENT | 3556.93 | 4268.31 | 0.320 | 0.384 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 31.04 | 0.00635 |
T SE APARTMENT | 3722.87 | 4467.45 | 0.335 | 0.402 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 33.70 | 0.00635 |
T NE APARTMENT | 2726.83 | 3272.20 | 0.246 | 0.295 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 33.70 | 0.00635 |
T N1 APARTMENT | 2054.50 | 2465.40 | 0.185 | 0.222 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:15:00 | 33.46 | 0.00635 |
T N2 APARTMENT | 2052.11 | 2462.53 | 0.185 | 0.222 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 33.70 | 0.00635 |
T S1 APARTMENT | 3015.12 | 3618.14 | 0.272 | 0.326 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
T S2 APARTMENT | 3025.67 | 3630.80 | 0.273 | 0.327 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 33.70 | 0.00635 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 2722.80 | 3267.36 | 0.139 | 0.167 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -26.30 | 0.00039 |
G NW APARTMENT | 2723.25 | 3267.90 | 0.139 | 0.167 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -26.30 | 0.00039 |
OFFICE | 3083.99 | 3700.79 | 0.158 | 0.189 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 18:45:00 | -26.30 | 0.00039 |
G NE APARTMENT | 2728.14 | 3273.77 | 0.140 | 0.168 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -26.30 | 0.00039 |
G N1 APARTMENT | 1887.40 | 2264.87 | 0.097 | 0.116 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -26.30 | 0.00039 |
G N2 APARTMENT | 1887.51 | 2265.01 | 0.097 | 0.116 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -26.30 | 0.00039 |
G S1 APARTMENT | 1884.95 | 2261.94 | 0.096 | 0.116 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -26.30 | 0.00039 |
G S2 APARTMENT | 1890.36 | 2268.44 | 0.097 | 0.116 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -26.30 | 0.00039 |
F2 SW APARTMENT | 2460.15 | 2952.19 | 0.126 | 0.151 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F2 NW APARTMENT | 2449.73 | 2939.68 | 0.125 | 0.150 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F2 SE APARTMENT | 2481.45 | 2977.74 | 0.127 | 0.152 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F2 NE APARTMENT | 2455.76 | 2946.91 | 0.126 | 0.151 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F2 N1 APARTMENT | 1443.93 | 1732.71 | 0.074 | 0.089 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F2 N2 APARTMENT | 1444.07 | 1732.88 | 0.074 | 0.089 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F2 S1 APARTMENT | 1457.04 | 1748.44 | 0.075 | 0.090 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F2 S2 APARTMENT | 1458.10 | 1749.72 | 0.075 | 0.090 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F3 SW APARTMENT | 2420.17 | 2904.20 | 0.124 | 0.149 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F3 NW APARTMENT | 2412.03 | 2894.43 | 0.123 | 0.148 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F3 SE APARTMENT | 2427.61 | 2913.13 | 0.124 | 0.149 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F3 NE APARTMENT | 2417.94 | 2901.52 | 0.124 | 0.149 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F3 N1 APARTMENT | 1373.48 | 1648.17 | 0.070 | 0.084 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F3 N2 APARTMENT | 1373.61 | 1648.34 | 0.070 | 0.084 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F3 S1 APARTMENT | 1382.66 | 1659.20 | 0.071 | 0.085 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F3 S2 APARTMENT | 1382.93 | 1659.52 | 0.071 | 0.085 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F4 SW APARTMENT | 2461.43 | 2953.72 | 0.126 | 0.151 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F4 NW APARTMENT | 2454.42 | 2945.30 | 0.126 | 0.151 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F4 SE APARTMENT | 2467.21 | 2960.66 | 0.126 | 0.152 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F4 NE APARTMENT | 2460.06 | 2952.07 | 0.126 | 0.151 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F4 N1 APARTMENT | 1387.46 | 1664.95 | 0.071 | 0.085 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F4 N2 APARTMENT | 1387.59 | 1665.11 | 0.071 | 0.085 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F4 S1 APARTMENT | 1395.28 | 1674.34 | 0.071 | 0.086 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F4 S2 APARTMENT | 1395.43 | 1674.51 | 0.071 | 0.086 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
M SW APARTMENT | 2489.64 | 2987.57 | 0.127 | 0.153 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
M NW APARTMENT | 2482.46 | 2978.95 | 0.127 | 0.152 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
M SE APARTMENT | 2494.96 | 2993.95 | 0.128 | 0.153 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
M NE APARTMENT | 2487.77 | 2985.32 | 0.127 | 0.153 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
M N1 APARTMENT | 1392.84 | 1671.41 | 0.071 | 0.086 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
M N2 APARTMENT | 1392.96 | 1671.55 | 0.071 | 0.086 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
M S1 APARTMENT | 1400.79 | 1680.95 | 0.072 | 0.086 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
M S2 APARTMENT | 1400.92 | 1681.10 | 0.072 | 0.086 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F6 SW APARTMENT | 2568.22 | 3081.87 | 0.131 | 0.158 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F6 NW APARTMENT | 2562.33 | 3074.80 | 0.131 | 0.157 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F6 SE APARTMENT | 2573.18 | 3087.82 | 0.132 | 0.158 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F6 NE APARTMENT | 2567.30 | 3080.76 | 0.131 | 0.158 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F6 N1 APARTMENT | 1452.40 | 1742.88 | 0.074 | 0.089 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F6 N2 APARTMENT | 1452.52 | 1743.02 | 0.074 | 0.089 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F6 S1 APARTMENT | 1459.05 | 1750.86 | 0.075 | 0.090 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F6 S2 APARTMENT | 1459.16 | 1751.00 | 0.075 | 0.090 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F7 SW APARTMENT | 2623.75 | 3148.50 | 0.134 | 0.161 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F7 NW APARTMENT | 2618.22 | 3141.86 | 0.134 | 0.161 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F7 SE APARTMENT | 2628.36 | 3154.03 | 0.135 | 0.161 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F7 NE APARTMENT | 2622.83 | 3147.39 | 0.134 | 0.161 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F7 N1 APARTMENT | 1491.06 | 1789.27 | 0.076 | 0.092 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F7 N2 APARTMENT | 1491.17 | 1789.40 | 0.076 | 0.092 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F7 S1 APARTMENT | 1497.37 | 1796.84 | 0.077 | 0.092 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F7 S2 APARTMENT | 1497.47 | 1796.97 | 0.077 | 0.092 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F8 SW APARTMENT | 2687.22 | 3224.66 | 0.138 | 0.165 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F8 NW APARTMENT | 2681.72 | 3218.07 | 0.137 | 0.165 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F8 SE APARTMENT | 2691.48 | 3229.78 | 0.138 | 0.165 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F8 NE APARTMENT | 2685.99 | 3223.18 | 0.137 | 0.165 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F8 N1 APARTMENT | 1539.39 | 1847.27 | 0.079 | 0.095 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F8 N2 APARTMENT | 1539.49 | 1847.38 | 0.079 | 0.095 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F8 S1 APARTMENT | 1545.66 | 1854.79 | 0.079 | 0.095 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F8 S2 APARTMENT | 1545.75 | 1854.90 | 0.079 | 0.095 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F9 SW APARTMENT | 2905.01 | 3486.01 | 0.149 | 0.178 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F9 NW APARTMENT | 2896.62 | 3475.94 | 0.148 | 0.178 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F9 SE APARTMENT | 2908.97 | 3490.77 | 0.149 | 0.179 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F9 NE APARTMENT | 2900.58 | 3480.70 | 0.148 | 0.178 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F9 N1 APARTMENT | 1731.00 | 2077.20 | 0.089 | 0.106 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F9 N2 APARTMENT | 1731.09 | 2077.31 | 0.089 | 0.106 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F9 S1 APARTMENT | 1739.79 | 2087.75 | 0.089 | 0.107 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
F9 S2 APARTMENT | 1739.88 | 2087.85 | 0.089 | 0.107 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
T SW APARTMENT | 3759.09 | 4510.91 | 0.192 | 0.231 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
T NW APARTMENT | 3759.29 | 4511.15 | 0.192 | 0.231 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
T SE APARTMENT | 3762.50 | 4515.00 | 0.193 | 0.231 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
T NE APARTMENT | 3762.70 | 4515.24 | 0.193 | 0.231 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
T N1 APARTMENT | 2642.90 | 3171.48 | 0.135 | 0.162 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
T N2 APARTMENT | 2642.99 | 3171.58 | 0.135 | 0.162 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
T S1 APARTMENT | 2640.60 | 3168.72 | 0.135 | 0.162 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
T S2 APARTMENT | 2640.68 | 3168.82 | 0.135 | 0.162 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 15:00:00 | -26.30 | 0.00039 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
AIRLOOP G SW | 0.26 | 0.26 | 0.17 | 0.17 |
AIRLOOP G NW | 0.23 | 0.23 | 0.17 | 0.17 |
AIRLOOP OFFICE | 0.39 | 0.39 | 0.19 | 0.19 |
AIRLOOP G NE | 0.16 | 0.16 | 0.17 | 0.17 |
AIRLOOP G N1 | 0.11 | 0.11 | 0.12 | 0.12 |
AIRLOOP G N2 | 0.11 | 0.11 | 0.12 | 0.12 |
AIRLOOP G S1 | 0.17 | 0.17 | 0.12 | 0.12 |
AIRLOOP G S2 | 0.17 | 0.17 | 0.12 | 0.12 |
AIRLOOP F2 SW | 0.34 | 0.34 | 0.15 | 0.15 |
AIRLOOP F2 NW | 0.30 | 0.30 | 0.15 | 0.15 |
AIRLOOP F2 SE | 0.33 | 0.33 | 0.15 | 0.15 |
AIRLOOP F2 NE | 0.22 | 0.22 | 0.15 | 0.15 |
AIRLOOP F2 N1 | 0.15 | 0.15 | 0.09 | 0.09 |
AIRLOOP F2 N2 | 0.15 | 0.15 | 0.09 | 0.09 |
AIRLOOP F2 S1 | 0.22 | 0.22 | 0.09 | 0.09 |
AIRLOOP F2 S2 | 0.22 | 0.22 | 0.09 | 0.09 |
AIRLOOP F3 SW | 0.34 | 0.34 | 0.15 | 0.15 |
AIRLOOP F3 NW | 0.31 | 0.31 | 0.15 | 0.15 |
AIRLOOP F3 SE | 0.31 | 0.31 | 0.15 | 0.15 |
AIRLOOP F3 NE | 0.23 | 0.23 | 0.15 | 0.15 |
AIRLOOP F3 N1 | 0.16 | 0.16 | 0.08 | 0.08 |
AIRLOOP F3 N2 | 0.16 | 0.16 | 0.08 | 0.08 |
AIRLOOP F3 S1 | 0.23 | 0.23 | 0.08 | 0.08 |
AIRLOOP F3 S2 | 0.23 | 0.23 | 0.08 | 0.08 |
AIRLOOP F4 SW | 0.34 | 0.34 | 0.15 | 0.15 |
AIRLOOP F4 NW | 0.31 | 0.31 | 0.15 | 0.15 |
AIRLOOP F4 SE | 0.32 | 0.32 | 0.15 | 0.15 |
AIRLOOP F4 NE | 0.23 | 0.23 | 0.15 | 0.15 |
AIRLOOP F4 N1 | 0.16 | 0.16 | 0.09 | 0.09 |
AIRLOOP F4 N2 | 0.16 | 0.16 | 0.09 | 0.09 |
AIRLOOP F4 S1 | 0.23 | 0.23 | 0.09 | 0.09 |
AIRLOOP F4 S2 | 0.23 | 0.23 | 0.09 | 0.09 |
AIRLOOP M SW | 0.35 | 0.35 | 0.15 | 0.15 |
AIRLOOP M NW | 0.31 | 0.31 | 0.15 | 0.15 |
AIRLOOP M SE | 0.32 | 0.32 | 0.15 | 0.15 |
AIRLOOP M NE | 0.23 | 0.23 | 0.15 | 0.15 |
AIRLOOP M N1 | 0.16 | 0.16 | 0.09 | 0.09 |
AIRLOOP M N2 | 0.16 | 0.16 | 0.09 | 0.09 |
AIRLOOP M S1 | 0.23 | 0.23 | 0.09 | 0.09 |
AIRLOOP M S2 | 0.24 | 0.24 | 0.09 | 0.09 |
AIRLOOP F6 SW | 0.34 | 0.34 | 0.16 | 0.16 |
AIRLOOP F6 NW | 0.31 | 0.31 | 0.16 | 0.16 |
AIRLOOP F6 SE | 0.32 | 0.32 | 0.16 | 0.16 |
AIRLOOP F6 NE | 0.23 | 0.23 | 0.16 | 0.16 |
AIRLOOP F6 N1 | 0.16 | 0.16 | 0.09 | 0.09 |
AIRLOOP F6 N2 | 0.16 | 0.16 | 0.09 | 0.09 |
AIRLOOP F6 S1 | 0.23 | 0.23 | 0.09 | 0.09 |
AIRLOOP F6 S2 | 0.23 | 0.23 | 0.09 | 0.09 |
AIRLOOP F7 SW | 0.34 | 0.34 | 0.16 | 0.16 |
AIRLOOP F7 NW | 0.31 | 0.31 | 0.16 | 0.16 |
AIRLOOP F7 SE | 0.32 | 0.32 | 0.16 | 0.16 |
AIRLOOP F7 NE | 0.23 | 0.23 | 0.16 | 0.16 |
AIRLOOP F7 N1 | 0.16 | 0.16 | 0.09 | 0.09 |
AIRLOOP F7 N2 | 0.16 | 0.16 | 0.09 | 0.09 |
AIRLOOP F7 S1 | 0.23 | 0.23 | 0.09 | 0.09 |
AIRLOOP F7 S2 | 0.23 | 0.23 | 0.09 | 0.09 |
AIRLOOP F8 SW | 0.35 | 0.35 | 0.17 | 0.17 |
AIRLOOP F8 NW | 0.31 | 0.31 | 0.16 | 0.16 |
AIRLOOP F8 SE | 0.32 | 0.32 | 0.17 | 0.17 |
AIRLOOP F8 NE | 0.23 | 0.23 | 0.16 | 0.16 |
AIRLOOP F8 N1 | 0.16 | 0.16 | 0.09 | 0.09 |
AIRLOOP F8 N2 | 0.16 | 0.16 | 0.09 | 0.09 |
AIRLOOP F8 S1 | 0.23 | 0.23 | 0.09 | 0.09 |
AIRLOOP F8 S2 | 0.23 | 0.23 | 0.09 | 0.09 |
AIRLOOP F9 SW | 0.36 | 0.36 | 0.18 | 0.18 |
AIRLOOP F9 NW | 0.32 | 0.32 | 0.18 | 0.18 |
AIRLOOP F9 SE | 0.33 | 0.33 | 0.18 | 0.18 |
AIRLOOP F9 NE | 0.23 | 0.23 | 0.18 | 0.18 |
AIRLOOP F9 N1 | 0.17 | 0.17 | 0.11 | 0.11 |
AIRLOOP F9 N2 | 0.17 | 0.17 | 0.11 | 0.11 |
AIRLOOP F9 S1 | 0.24 | 0.24 | 0.11 | 0.11 |
AIRLOOP F9 S2 | 0.24 | 0.24 | 0.11 | 0.11 |
AIRLOOP T SW | 0.44 | 0.44 | 0.23 | 0.23 |
AIRLOOP T NW | 0.38 | 0.38 | 0.23 | 0.23 |
AIRLOOP T SE | 0.40 | 0.40 | 0.23 | 0.23 |
AIRLOOP T NE | 0.29 | 0.29 | 0.23 | 0.23 |
AIRLOOP T N1 | 0.22 | 0.22 | 0.16 | 0.16 |
AIRLOOP T N2 | 0.22 | 0.22 | 0.16 | 0.16 |
AIRLOOP T S1 | 0.33 | 0.33 | 0.16 | 0.16 |
AIRLOOP T S2 | 0.33 | 0.33 | 0.16 | 0.16 |
Report: System Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:13
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 2054.25 | 6175.50 | 638.50 |
G NW APARTMENT | 2152.25 | 6734.00 | 1169.75 |
OFFICE | 813.50 | 1124.00 | 68.25 |
G NE APARTMENT | 2347.00 | 6724.50 | 1229.75 |
G N1 APARTMENT | 1275.50 | 7049.25 | 574.50 |
G N2 APARTMENT | 1283.75 | 7047.00 | 574.75 |
G S1 APARTMENT | 1456.00 | 6346.50 | 253.75 |
G S2 APARTMENT | 1495.50 | 6266.25 | 237.00 |
F2 SW APARTMENT | 2416.00 | 5098.25 | 235.75 |
F2 NW APARTMENT | 2172.00 | 5990.00 | 536.75 |
F2 SE APARTMENT | 2646.25 | 4844.25 | 202.75 |
F2 NE APARTMENT | 2291.25 | 6065.25 | 587.50 |
F2 N1 APARTMENT | 1482.25 | 6267.25 | 143.25 |
F2 N2 APARTMENT | 1490.75 | 6267.50 | 144.25 |
F2 S1 APARTMENT | 2095.50 | 5040.50 | 43.75 |
F2 S2 APARTMENT | 2119.75 | 4991.75 | 43.25 |
F3 SW APARTMENT | 2497.75 | 4904.50 | 191.75 |
F3 NW APARTMENT | 2191.25 | 5876.00 | 470.00 |
F3 SE APARTMENT | 2606.75 | 4864.00 | 196.75 |
F3 NE APARTMENT | 2299.75 | 5949.50 | 504.25 |
F3 N1 APARTMENT | 1558.00 | 6075.50 | 102.50 |
F3 N2 APARTMENT | 1565.25 | 6078.75 | 103.25 |
F3 S1 APARTMENT | 2262.50 | 4672.50 | 29.75 |
F3 S2 APARTMENT | 2276.75 | 4654.50 | 29.75 |
F4 SW APARTMENT | 2518.75 | 4888.75 | 191.00 |
F4 NW APARTMENT | 2205.25 | 5867.00 | 470.50 |
F4 SE APARTMENT | 2600.25 | 4883.00 | 201.75 |
F4 NE APARTMENT | 2307.75 | 5941.50 | 502.25 |
F4 N1 APARTMENT | 1583.25 | 6030.75 | 99.00 |
F4 N2 APARTMENT | 1589.50 | 6034.25 | 99.25 |
F4 S1 APARTMENT | 2316.50 | 4598.00 | 26.75 |
F4 S2 APARTMENT | 2326.50 | 4589.25 | 26.75 |
M SW APARTMENT | 2516.75 | 4904.75 | 188.00 |
M NW APARTMENT | 2200.75 | 5883.00 | 458.75 |
M SE APARTMENT | 2598.75 | 4897.00 | 198.25 |
M NE APARTMENT | 2301.00 | 5953.50 | 489.50 |
M N1 APARTMENT | 1599.25 | 6024.75 | 90.50 |
M N2 APARTMENT | 1603.50 | 6026.50 | 91.75 |
M S1 APARTMENT | 2333.50 | 4595.50 | 25.50 |
M S2 APARTMENT | 2337.50 | 4588.25 | 25.50 |
F6 SW APARTMENT | 2434.00 | 5053.00 | 217.00 |
F6 NW APARTMENT | 2174.25 | 5983.00 | 511.50 |
F6 SE APARTMENT | 2533.50 | 5040.75 | 230.25 |
F6 NE APARTMENT | 2264.25 | 6056.75 | 545.25 |
F6 N1 APARTMENT | 1533.50 | 6151.25 | 113.50 |
F6 N2 APARTMENT | 1541.75 | 6159.25 | 114.50 |
F6 S1 APARTMENT | 2236.25 | 4767.50 | 32.75 |
F6 S2 APARTMENT | 2242.75 | 4764.25 | 32.75 |
F7 SW APARTMENT | 2381.00 | 5153.50 | 235.75 |
F7 NW APARTMENT | 2152.50 | 6056.25 | 541.75 |
F7 SE APARTMENT | 2483.75 | 5142.25 | 251.75 |
F7 NE APARTMENT | 2251.50 | 6134.50 | 581.75 |
F7 N1 APARTMENT | 1499.25 | 6241.50 | 127.25 |
F7 N2 APARTMENT | 1505.50 | 6247.75 | 128.50 |
F7 S1 APARTMENT | 2165.50 | 4911.25 | 37.50 |
F7 S2 APARTMENT | 2169.25 | 4907.00 | 37.75 |
F8 SW APARTMENT | 2348.50 | 5247.75 | 259.75 |
F8 NW APARTMENT | 2147.50 | 6134.25 | 578.50 |
F8 SE APARTMENT | 2446.75 | 5248.50 | 271.50 |
F8 NE APARTMENT | 2256.00 | 6197.00 | 619.00 |
F8 N1 APARTMENT | 1480.50 | 6313.50 | 143.75 |
F8 N2 APARTMENT | 1489.50 | 6317.75 | 144.50 |
F8 S1 APARTMENT | 2105.25 | 5044.25 | 42.50 |
F8 S2 APARTMENT | 2107.00 | 5041.75 | 42.50 |
F9 SW APARTMENT | 2373.50 | 5390.75 | 354.00 |
F9 NW APARTMENT | 2273.50 | 6219.50 | 733.50 |
F9 SE APARTMENT | 2464.25 | 5405.75 | 365.00 |
F9 NE APARTMENT | 2390.00 | 6264.50 | 780.75 |
F9 N1 APARTMENT | 1541.75 | 6383.50 | 214.25 |
F9 N2 APARTMENT | 1547.25 | 6384.50 | 216.75 |
F9 S1 APARTMENT | 2033.25 | 5249.50 | 73.50 |
F9 S2 APARTMENT | 2033.75 | 5242.25 | 73.00 |
T SW APARTMENT | 3293.50 | 5701.50 | 1410.00 |
T NW APARTMENT | 3403.00 | 6454.50 | 2009.25 |
T SE APARTMENT | 3390.25 | 5661.50 | 1423.25 |
T NE APARTMENT | 3497.75 | 6503.75 | 2017.25 |
T N1 APARTMENT | 2413.00 | 6604.50 | 1182.75 |
T N2 APARTMENT | 2417.50 | 6600.00 | 1184.25 |
T S1 APARTMENT | 2553.25 | 5545.50 | 695.50 |
T S2 APARTMENT | 2562.00 | 5540.00 | 696.50 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 5067.75 | 7244.50 | 2179.50 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 2.50 | 21.75 | 2.50 | 21.75 |
G NW APARTMENT | 1.50 | 4.00 | 1.50 | 4.00 |
OFFICE | 1.00 | 4.75 | 0.00 | 4.75 |
G NE APARTMENT | 3.75 | 0.00 | 3.75 | 0.00 |
G N1 APARTMENT | 2.75 | 4.50 | 2.75 | 4.50 |
G N2 APARTMENT | 3.75 | 3.00 | 3.75 | 3.00 |
G S1 APARTMENT | 3.75 | 22.75 | 3.75 | 22.75 |
G S2 APARTMENT | 5.25 | 20.50 | 5.25 | 20.50 |
F2 SW APARTMENT | 0.75 | 17.25 | 0.75 | 17.25 |
F2 NW APARTMENT | 1.75 | 1.50 | 1.75 | 1.50 |
F2 SE APARTMENT | 2.50 | 0.00 | 2.50 | 0.00 |
F2 NE APARTMENT | 2.00 | 0.00 | 2.00 | 0.00 |
F2 N1 APARTMENT | 3.75 | 4.75 | 3.75 | 4.75 |
F2 N2 APARTMENT | 2.00 | 7.75 | 2.00 | 7.75 |
F2 S1 APARTMENT | 4.00 | 23.75 | 4.00 | 23.75 |
F2 S2 APARTMENT | 2.50 | 23.00 | 2.50 | 23.00 |
F3 SW APARTMENT | 1.25 | 23.25 | 1.25 | 23.25 |
F3 NW APARTMENT | 0.50 | 2.50 | 0.50 | 2.50 |
F3 SE APARTMENT | 0.75 | 5.00 | 0.75 | 5.00 |
F3 NE APARTMENT | 2.25 | 7.50 | 2.25 | 7.50 |
F3 N1 APARTMENT | 3.75 | 14.25 | 3.75 | 14.25 |
F3 N2 APARTMENT | 4.50 | 16.00 | 4.50 | 16.00 |
F3 S1 APARTMENT | 4.75 | 26.50 | 4.75 | 26.50 |
F3 S2 APARTMENT | 3.00 | 26.25 | 3.00 | 26.25 |
F4 SW APARTMENT | 1.75 | 25.25 | 1.75 | 25.25 |
F4 NW APARTMENT | 1.25 | 4.50 | 1.25 | 4.50 |
F4 SE APARTMENT | 1.00 | 6.25 | 1.00 | 6.25 |
F4 NE APARTMENT | 2.00 | 9.75 | 2.00 | 9.75 |
F4 N1 APARTMENT | 3.50 | 18.25 | 3.50 | 18.25 |
F4 N2 APARTMENT | 4.75 | 19.50 | 4.75 | 19.50 |
F4 S1 APARTMENT | 4.00 | 26.75 | 4.00 | 26.75 |
F4 S2 APARTMENT | 2.00 | 26.50 | 2.00 | 26.50 |
M SW APARTMENT | 0.50 | 23.50 | 0.50 | 23.50 |
M NW APARTMENT | 0.50 | 6.50 | 0.50 | 6.50 |
M SE APARTMENT | 2.25 | 7.75 | 2.25 | 7.75 |
M NE APARTMENT | 2.50 | 12.75 | 2.50 | 12.75 |
M N1 APARTMENT | 3.75 | 20.00 | 3.75 | 20.00 |
M N2 APARTMENT | 4.25 | 24.00 | 4.25 | 24.00 |
M S1 APARTMENT | 3.50 | 27.25 | 3.50 | 27.25 |
M S2 APARTMENT | 3.25 | 26.50 | 3.25 | 26.50 |
F6 SW APARTMENT | 1.75 | 24.75 | 1.75 | 24.75 |
F6 NW APARTMENT | 0.50 | 6.75 | 0.50 | 6.75 |
F6 SE APARTMENT | 1.50 | 8.75 | 1.50 | 8.75 |
F6 NE APARTMENT | 2.25 | 14.50 | 2.25 | 14.50 |
F6 N1 APARTMENT | 2.75 | 24.00 | 2.75 | 24.00 |
F6 N2 APARTMENT | 2.75 | 25.50 | 2.75 | 25.50 |
F6 S1 APARTMENT | 1.00 | 27.50 | 1.00 | 27.50 |
F6 S2 APARTMENT | 1.00 | 26.75 | 1.00 | 26.75 |
F7 SW APARTMENT | 1.25 | 25.50 | 1.25 | 25.50 |
F7 NW APARTMENT | 0.25 | 7.25 | 0.25 | 7.25 |
F7 SE APARTMENT | 1.75 | 9.50 | 1.75 | 9.50 |
F7 NE APARTMENT | 1.50 | 17.00 | 1.50 | 17.00 |
F7 N1 APARTMENT | 3.75 | 26.25 | 3.75 | 26.25 |
F7 N2 APARTMENT | 4.00 | 27.50 | 4.00 | 27.50 |
F7 S1 APARTMENT | 3.50 | 28.00 | 3.50 | 28.00 |
F7 S2 APARTMENT | 4.00 | 28.25 | 4.00 | 28.25 |
F8 SW APARTMENT | 1.50 | 25.25 | 1.50 | 25.25 |
F8 NW APARTMENT | 0.50 | 7.25 | 0.50 | 7.25 |
F8 SE APARTMENT | 2.25 | 9.50 | 2.25 | 9.50 |
F8 NE APARTMENT | 2.25 | 18.50 | 2.25 | 18.50 |
F8 N1 APARTMENT | 4.00 | 26.00 | 4.00 | 26.00 |
F8 N2 APARTMENT | 5.50 | 27.75 | 5.50 | 27.75 |
F8 S1 APARTMENT | 3.50 | 28.25 | 3.50 | 28.25 |
F8 S2 APARTMENT | 4.00 | 27.75 | 4.00 | 27.75 |
F9 SW APARTMENT | 2.25 | 22.50 | 2.25 | 22.50 |
F9 NW APARTMENT | 0.50 | 7.50 | 0.50 | 7.50 |
F9 SE APARTMENT | 1.25 | 9.50 | 1.25 | 9.50 |
F9 NE APARTMENT | 1.00 | 23.75 | 1.00 | 23.75 |
F9 N1 APARTMENT | 3.50 | 23.50 | 3.50 | 23.50 |
F9 N2 APARTMENT | 3.75 | 25.25 | 3.75 | 25.25 |
F9 S1 APARTMENT | 0.75 | 25.75 | 0.75 | 25.75 |
F9 S2 APARTMENT | 1.75 | 25.00 | 1.75 | 25.00 |
T SW APARTMENT | 0.00 | 7.75 | 0.00 | 7.75 |
T NW APARTMENT | 0.00 | 11.00 | 0.00 | 11.00 |
T SE APARTMENT | 0.00 | 3.00 | 0.00 | 3.00 |
T NE APARTMENT | 0.00 | 2.50 | 0.00 | 2.50 |
T N1 APARTMENT | 1.25 | 3.50 | 1.25 | 3.50 |
T N2 APARTMENT | 0.25 | 2.25 | 0.25 | 2.25 |
T S1 APARTMENT | 1.25 | 10.75 | 1.25 | 10.75 |
T S2 APARTMENT | 0.00 | 10.25 | 0.00 | 10.25 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 149.50 | 74.25 | 148.75 | 74.25 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:13
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.148 | 0.000 | 0.238 |
G NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.148 | 0.000 | 0.233 |
OFFICE | 0.94 | 1.00 | 268.96 | 0.519 | 0.168 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.148 | 0.000 | 0.234 |
G N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.089 | 0.000 | 0.227 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.089 | 0.000 | 0.227 |
G S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.089 | 0.000 | 0.235 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.089 | 0.000 | 0.236 |
F2 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.213 | 0.000 | 0.272 |
F2 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.212 | 0.000 | 0.269 |
F2 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.213 | 0.000 | 0.274 |
F2 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.212 | 0.000 | 0.269 |
F2 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.128 | 0.000 | 0.264 |
F2 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.128 | 0.000 | 0.264 |
F2 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.128 | 0.000 | 0.271 |
F2 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.128 | 0.000 | 0.271 |
F3 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.252 | 0.000 | 0.294 |
F3 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.251 | 0.000 | 0.291 |
F3 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.252 | 0.000 | 0.295 |
F3 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.251 | 0.000 | 0.291 |
F3 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.152 | 0.000 | 0.287 |
F3 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.152 | 0.000 | 0.287 |
F3 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.152 | 0.000 | 0.293 |
F3 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.152 | 0.000 | 0.293 |
F4 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.281 | 0.000 | 0.302 |
F4 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.281 | 0.000 | 0.299 |
F4 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.281 | 0.000 | 0.302 |
F4 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.281 | 0.000 | 0.300 |
F4 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.169 | 0.000 | 0.296 |
F4 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.169 | 0.000 | 0.296 |
F4 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.170 | 0.000 | 0.301 |
F4 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.170 | 0.000 | 0.301 |
M SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.306 | 0.000 | 0.315 |
M NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.305 | 0.000 | 0.313 |
M SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.305 | 0.000 | 0.315 |
M NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.305 | 0.000 | 0.313 |
M N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.184 | 0.000 | 0.309 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.184 | 0.000 | 0.309 |
M S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.184 | 0.000 | 0.314 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.184 | 0.000 | 0.314 |
F6 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.326 | 0.000 | 0.325 |
F6 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.326 | 0.000 | 0.323 |
F6 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.326 | 0.000 | 0.326 |
F6 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.326 | 0.000 | 0.323 |
F6 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.197 | 0.000 | 0.320 |
F6 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.197 | 0.000 | 0.320 |
F6 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.197 | 0.000 | 0.324 |
F6 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.197 | 0.000 | 0.324 |
F7 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.345 | 0.000 | 0.335 |
F7 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.344 | 0.000 | 0.332 |
F7 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.345 | 0.000 | 0.335 |
F7 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.344 | 0.000 | 0.333 |
F7 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.208 | 0.000 | 0.329 |
F7 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.208 | 0.000 | 0.329 |
F7 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.208 | 0.000 | 0.333 |
F7 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.208 | 0.000 | 0.333 |
F8 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.362 | 0.000 | 0.344 |
F8 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.361 | 0.000 | 0.342 |
F8 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.362 | 0.000 | 0.345 |
F8 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.361 | 0.000 | 0.342 |
F8 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.218 | 0.000 | 0.339 |
F8 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.218 | 0.000 | 0.339 |
F8 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.218 | 0.000 | 0.343 |
F8 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.218 | 0.000 | 0.343 |
F9 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.377 | 0.000 | 0.351 |
F9 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.376 | 0.000 | 0.349 |
F9 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.377 | 0.000 | 0.352 |
F9 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.376 | 0.000 | 0.349 |
F9 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.227 | 0.000 | 0.346 |
F9 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.227 | 0.000 | 0.346 |
F9 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.354 | 0.227 | 0.000 | 0.350 |
F9 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.227 | 0.000 | 0.350 |
T SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.391 | 0.000 | 0.357 |
T NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.390 | 0.000 | 0.357 |
T SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.391 | 0.000 | 0.358 |
T NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.390 | 0.000 | 0.357 |
T N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.235 | 0.000 | 0.354 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.235 | 0.000 | 0.354 |
T S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.353 | 0.236 | 0.000 | 0.356 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.236 | 0.000 | 0.356 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.96 | 0.504 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
F2 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F2 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F2 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F2 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F2 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F2 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
F2 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F2 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
F3 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F3 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F3 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F3 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F3 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F3 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
F3 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F3 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
F4 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F4 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F4 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F4 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F4 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F4 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
F4 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F4 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
F6 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F6 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F6 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F6 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F6 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F6 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
F6 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F6 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
F7 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F7 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F7 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F7 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F7 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F7 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
F7 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F7 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
F8 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F8 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F8 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F8 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F8 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F8 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
F8 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F8 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
F9 SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F9 NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F9 SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F9 NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F9 N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F9 N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
F9 S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
F9 S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.96 | 0.343 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.343 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:13
Surfaces by ClassTotal | Outdoors | |
Wall | 420 | 140 |
Floor | 90 | 9 |
Roof | 90 | 9 |
Internal Mass | 80 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 140 | 140 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 80 |
Conditioned Zones | 80 |
Unconditioned Zones | 10 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 4156 |
Defaulted Fields | 814 |
Fields with Defaults | 11184 |
Autosized Fields | 1293 |
Autosizable Fields | 1630 |
Autocalculated Fields | 907 |
Autocalculatable Fields | 1710 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2015-09-09 19:11:13
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 2904.97 | 58092.92 | 16-MAY-05:00 | 170607.63 | 25-DEC-17:15 |
Electricity:Building | 1433.88 | 25760.85 | 01-JAN-03:15 | 70162.48 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity | 296.56 | 6715.87 | 01-JAN-00:15 | 14401.37 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 242.55 | 5824.91 | 01-JAN-00:15 | 11484.27 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 39.38 | 663.42 | 01-JAN-00:15 | 2934.49 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 29.88 | 469.18 | 01-JAN-00:15 | 2345.88 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F2 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F2 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F2 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F2 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F3 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F3 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F3 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F3 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F4 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F4 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F4 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F4 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:M SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M CORRIDOR | 32.88 | 1042.61 | 01-JAN-00:15 | 1042.61 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 32.88 | 1042.61 | 01-JAN-00:15 | 1042.61 | 01-JAN-00:15 |
Electricity:Zone:F6 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F6 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F6 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F6 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F7 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F7 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F7 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F7 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F8 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F8 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F8 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F8 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:F9 SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:F9 S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:F9 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:F9 CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
Electricity:Zone:T SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T CORRIDOR | 179.47 | 1701.70 | 01-JAN-00:15 | 10868.20 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 16.44 | 521.30 | 01-JAN-00:15 | 521.30 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 54.01 | 890.97 | 01-JAN-00:15 | 2917.11 | 01-JAN-19:15 |
InteriorEquipment:Electricity | 1137.32 | 19044.98 | 01-JAN-03:15 | 57142.09 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 1137.32 | 19044.98 | 01-JAN-03:15 | 57142.09 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 9.50 | 194.24 | 01-JAN-00:15 | 588.62 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T CORRIDOR | 163.03 | 1180.40 | 01-JAN-00:15 | 10346.90 | 01-JAN-07:15 |
Fans:Electricity | 737.27 | 23378.63 | 01-JAN-01:45 | 23378.63 | 01-JAN-00:15 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F2 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F3 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F4 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F6 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F7 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F8 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:F9 S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Electricity:HVAC | 1243.43 | 24039.88 | 19-MAY-02:30 | 105383.80 | 25-DEC-09:00 |
ElectricityProduced:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityProduced:HVAC | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricityProduced | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 2904.97 | 58092.92 | 16-MAY-05:00 | 170607.63 | 25-DEC-17:15 |
ElectricityPurchased:Plant | 2904.97 | 58092.92 | 16-MAY-05:00 | 170607.63 | 25-DEC-17:15 |
Cogeneration:ElectricityPurchased | 2904.97 | 58092.92 | 16-MAY-05:00 | 170607.63 | 25-DEC-17:15 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 2904.97 | 58092.92 | 16-MAY-05:00 | 170607.63 | 25-DEC-17:15 |
ElectricityNet:Plant | 2904.97 | 58092.92 | 16-MAY-05:00 | 170607.63 | 25-DEC-17:15 |
Cogeneration:ElectricityNet | 2904.97 | 58092.92 | 16-MAY-05:00 | 170607.63 | 25-DEC-17:15 |
ExteriorLights:Electricity | 162.57 | 0.00 | 01-JAN-08:30 | 10364.00 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 162.57 | 0.00 | 01-JAN-08:30 | 10364.00 | 01-JAN-00:15 |
General:Fans:Electricity | 737.27 | 23378.63 | 01-JAN-01:45 | 23378.63 | 01-JAN-00:15 |
Cooling:Electricity | 234.17 | 0.00 | 01-JAN-00:15 | 65255.86 | 10-AUG-15:45 |
Heating:Electricity | 235.82 | 0.00 | 18-MAR-15:15 | 80922.95 | 25-DEC-09:00 |
Electricity:Plant | 65.09 | 36.93 | 26-MAR-20:45 | 3895.07 | 30-JUN-15:30 |
HeatRejection:Electricity | 8.43 | 0.00 | 01-JAN-00:15 | 2080.60 | 30-JUN-15:30 |
Boiler Parasitic:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Pumps:Electricity | 56.66 | 36.93 | 26-MAR-20:45 | 1814.46 | 01-JAN-00:15 |
WIRED_LTG_ELECTRICITY | 0.44 | 0.00 | 01-JAN-00:15 | 21.60 | 01-JAN-19:30 |
WIRED_INT_EQUIP | 979.40 | 1018.50 | 01-JAN-00:15 | 10185.00 | 01-JAN-07:15 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 2104.04 | 2357.00 | 03-MAR-00:30 | 314234.36 | 25-DEC-09:00 |
Gas:Plant | 2104.04 | 2357.00 | 03-MAR-00:30 | 314234.36 | 25-DEC-09:00 |
WaterSystems:Gas | 1251.16 | 2357.00 | 01-JAN-00:15 | 85503.73 | 25-FEB-08:00 |
Water Heater:WaterSystems:Gas | 1251.16 | 2357.00 | 01-JAN-00:15 | 85503.73 | 25-FEB-08:00 |
Heating:Gas | 852.88 | 0.00 | 06-JAN-15:15 | 236095.98 | 25-DEC-09:15 |
Boiler:Heating:Gas | 852.88 | 0.00 | 06-JAN-15:15 | 236095.98 | 25-DEC-09:15 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
PlantLoopCoolingDemand:Facility | 917.66 | 0.00 | 01-JAN-00:15 | 278280.00 | 30-JUN-15:15 |
PlantLoopCoolingDemand:HVAC | 917.66 | 0.00 | 01-JAN-00:15 | 278280.00 | 30-JUN-15:15 |
CoolingCoils:PlantLoopCoolingDemand | 917.66 | 0.00 | 01-JAN-00:15 | 278280.00 | 30-JUN-15:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 5624.66 | 0.00 | 01-JAN-02:15 | 0.00 | 21-JUL-17:15 |
Water:Plant | 5624.66 | 0.00 | 01-JAN-02:15 | 0.00 | 21-JUL-17:15 |
WaterSystems:Water | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:Water | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
MainsWater:Facility | 5624.66 | 0.00 | 01-JAN-02:15 | 0.00 | 21-JUL-17:15 |
MainsWater:Plant | 5624.66 | 0.00 | 01-JAN-02:15 | 0.00 | 21-JUL-17:15 |
WaterSystems:MainsWater | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:MainsWater | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
sub cat:WaterSystems:Water | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
sub cat:WaterSystems:MainsWater | 4778.51 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
HeatRejection:Water | 846.14 | 0.00 | 01-JAN-00:15 | 0.00 | 21-JUL-17:00 |
HeatRejection:MainsWater | 846.14 | 0.00 | 01-JAN-00:15 | 0.00 | 21-JUL-17:00 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 1658.91 | 510.95 | 19-AUG-01:15 | 240341.45 | 25-DEC-09:00 |
PlantLoopHeatingDemand:Plant | 975.08 | 510.95 | 19-AUG-01:15 | 65790.15 | 22-FEB-08:00 |
WaterSystems:PlantLoopHeatingDemand | 975.08 | 510.95 | 19-AUG-01:15 | 65790.15 | 22-FEB-08:00 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 4514.65 | 5903.79 | 21-APR-02:00 | 696660.78 | 25-DEC-09:00 |
EnergyTransfer:Building | 1304.21 | 3668.00 | 04-MAY-18:00 | 201718.16 | 25-DEC-09:00 |
EnergyTransfer:Zone:G SW APARTMENT | 14.56 | 0.01 | 09-JUN-01:45 | 2591.79 | 02-SEP-17:30 |
Heating:EnergyTransfer | 564.55 | 0.00 | 04-MAR-16:15 | 201718.16 | 25-DEC-09:00 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 7.43 | 0.00 | 02-JAN-12:15 | 2398.99 | 25-DEC-09:00 |
Cooling:EnergyTransfer | 739.65 | 0.00 | 01-JAN-00:15 | 179244.09 | 30-JUN-15:15 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 7.13 | 0.00 | 01-JAN-00:15 | 2591.79 | 02-SEP-17:30 |
EnergyTransfer:Zone:G NW APARTMENT | 15.94 | 0.01 | 20-MAY-23:45 | 2526.78 | 25-DEC-09:00 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 11.71 | 0.00 | 11-FEB-16:15 | 2526.78 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 4.22 | 0.00 | 01-JAN-00:15 | 2255.70 | 28-JUN-18:30 |
EnergyTransfer:Zone:OFFICE | 21.30 | 0.01 | 29-MAY-19:15 | 3774.18 | 12-SEP-13:45 |
Heating:EnergyTransfer:Zone:OFFICE | 5.51 | 0.00 | 02-JAN-09:15 | 2411.26 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:OFFICE | 15.79 | 0.00 | 01-JAN-00:15 | 3774.18 | 12-SEP-13:45 |
EnergyTransfer:Zone:G NE APARTMENT | 16.07 | 0.12 | 01-JUN-23:30 | 2500.38 | 25-DEC-09:00 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 11.58 | 0.00 | 21-FEB-09:30 | 2500.38 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 4.49 | 0.00 | 01-JAN-00:15 | 1659.20 | 07-AUG-09:30 |
EnergyTransfer:Zone:G N1 APARTMENT | 10.23 | 0.00 | 05-MAR-21:00 | 1611.54 | 23-FEB-08:30 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 6.69 | 0.00 | 18-FEB-19:00 | 1611.54 | 23-FEB-08:30 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 3.54 | 0.00 | 01-JAN-00:15 | 1123.69 | 27-JUN-19:30 |
EnergyTransfer:Zone:G N2 APARTMENT | 10.23 | 0.04 | 14-JUL-08:00 | 1597.85 | 23-FEB-08:30 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 6.70 | 0.00 | 02-MAR-17:15 | 1597.85 | 23-FEB-08:30 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 3.53 | 0.00 | 01-JAN-00:15 | 1120.82 | 27-JUN-19:30 |
EnergyTransfer:Zone:G S1 APARTMENT | 9.97 | 0.02 | 03-AUG-10:15 | 1786.38 | 14-SEP-13:15 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 2.93 | 0.00 | 01-JAN-11:15 | 1443.59 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 7.04 | 0.00 | 01-JAN-00:15 | 1786.38 | 14-SEP-13:15 |
EnergyTransfer:Zone:G S2 APARTMENT | 10.06 | 0.01 | 26-APR-11:30 | 1857.92 | 14-SEP-13:30 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 2.78 | 0.00 | 01-JAN-11:30 | 1436.41 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 7.27 | 0.00 | 01-JAN-00:15 | 1857.92 | 14-SEP-13:30 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F2 SW APARTMENT | 17.34 | 0.03 | 28-APR-12:30 | 3328.30 | 02-SEP-17:30 |
Heating:EnergyTransfer:Zone:F2 SW APARTMENT | 5.27 | 0.00 | 01-JAN-11:30 | 2464.97 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT | 12.07 | 0.00 | 01-JAN-00:15 | 3328.30 | 02-SEP-17:30 |
EnergyTransfer:Zone:F2 NW APARTMENT | 16.93 | 0.10 | 25-MAY-04:00 | 2952.12 | 28-JUN-18:30 |
Heating:EnergyTransfer:Zone:F2 NW APARTMENT | 9.99 | 0.00 | 06-JAN-16:15 | 2668.54 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT | 6.94 | 0.00 | 01-JAN-00:15 | 2952.12 | 28-JUN-18:30 |
EnergyTransfer:Zone:F2 SE APARTMENT | 18.33 | 0.01 | 27-SEP-01:00 | 3266.02 | 13-SEP-12:45 |
Heating:EnergyTransfer:Zone:F2 SE APARTMENT | 4.57 | 0.00 | 01-JAN-10:00 | 2405.33 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT | 13.77 | 0.00 | 01-JAN-00:15 | 3266.02 | 13-SEP-12:45 |
EnergyTransfer:Zone:F2 NE APARTMENT | 17.37 | 0.01 | 02-MAY-14:45 | 2634.10 | 25-DEC-09:00 |
Heating:EnergyTransfer:Zone:F2 NE APARTMENT | 9.87 | 0.00 | 27-JAN-12:00 | 2634.10 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT | 7.49 | 0.00 | 01-JAN-00:15 | 2203.69 | 18-JUL-10:15 |
EnergyTransfer:Zone:F2 N1 APARTMENT | 10.01 | 0.01 | 02-AUG-19:30 | 1497.58 | 27-JUN-19:15 |
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT | 4.12 | 0.00 | 04-JAN-21:45 | 1483.29 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT | 5.90 | 0.00 | 01-JAN-00:15 | 1497.58 | 27-JUN-19:15 |
EnergyTransfer:Zone:F2 N2 APARTMENT | 10.03 | 0.00 | 12-DEC-13:00 | 1482.14 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT | 4.12 | 0.00 | 04-JAN-21:45 | 1482.14 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT | 5.91 | 0.00 | 01-JAN-00:15 | 1479.96 | 27-JUN-19:15 |
EnergyTransfer:Zone:F2 S1 APARTMENT | 13.53 | 0.05 | 10-FEB-09:00 | 2356.40 | 14-SEP-13:15 |
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT | 1.42 | 0.00 | 01-JAN-09:30 | 1236.39 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT | 12.11 | 0.00 | 01-JAN-00:15 | 2356.40 | 14-SEP-13:15 |
EnergyTransfer:Zone:F2 S2 APARTMENT | 13.64 | 0.09 | 21-APR-00:45 | 2382.93 | 14-SEP-13:15 |
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT | 1.39 | 0.00 | 01-JAN-09:30 | 1233.14 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT | 12.25 | 0.00 | 01-JAN-00:15 | 2382.93 | 14-SEP-13:15 |
EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F2 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F3 SW APARTMENT | 17.98 | 0.00 | 30-OCT-16:00 | 3343.93 | 02-SEP-17:30 |
Heating:EnergyTransfer:Zone:F3 SW APARTMENT | 5.12 | 0.00 | 01-JAN-11:30 | 2653.40 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT | 12.87 | 0.00 | 01-JAN-00:15 | 3343.93 | 02-SEP-17:30 |
EnergyTransfer:Zone:F3 NW APARTMENT | 17.26 | 0.01 | 16-SEP-09:45 | 2975.61 | 27-JUN-19:00 |
Heating:EnergyTransfer:Zone:F3 NW APARTMENT | 9.82 | 0.00 | 06-JAN-15:30 | 2879.60 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT | 7.44 | 0.00 | 01-JAN-00:15 | 2975.61 | 27-JUN-19:00 |
EnergyTransfer:Zone:F3 SE APARTMENT | 18.56 | 0.02 | 07-SEP-04:45 | 3172.76 | 12-SEP-13:30 |
Heating:EnergyTransfer:Zone:F3 SE APARTMENT | 4.97 | 0.00 | 01-JAN-10:00 | 2609.36 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT | 13.59 | 0.00 | 01-JAN-00:15 | 3172.76 | 12-SEP-13:30 |
EnergyTransfer:Zone:F3 NE APARTMENT | 17.75 | 0.01 | 21-APR-11:00 | 2845.16 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F3 NE APARTMENT | 9.72 | 0.00 | 27-JAN-11:45 | 2845.16 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT | 8.03 | 0.00 | 01-JAN-00:15 | 2244.49 | 21-JUL-10:00 |
EnergyTransfer:Zone:F3 N1 APARTMENT | 10.33 | 0.03 | 24-JUN-17:00 | 1580.91 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT | 3.72 | 0.00 | 02-JAN-22:00 | 1580.91 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT | 6.61 | 0.00 | 01-JAN-00:15 | 1534.62 | 16-JUL-19:00 |
EnergyTransfer:Zone:F3 N2 APARTMENT | 10.34 | 0.05 | 05-JUN-20:45 | 1579.71 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT | 3.72 | 0.00 | 02-JAN-22:00 | 1579.71 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT | 6.62 | 0.00 | 01-JAN-00:15 | 1517.68 | 16-JUL-19:00 |
EnergyTransfer:Zone:F3 S1 APARTMENT | 14.67 | 0.01 | 28-JAN-20:15 | 2412.94 | 14-SEP-13:15 |
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT | 1.26 | 0.00 | 01-JAN-09:30 | 1312.68 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT | 13.41 | 0.00 | 01-JAN-00:15 | 2412.94 | 14-SEP-13:15 |
EnergyTransfer:Zone:F3 S2 APARTMENT | 14.71 | 0.01 | 01-FEB-11:00 | 2425.91 | 14-SEP-13:15 |
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT | 1.26 | 0.00 | 01-JAN-09:30 | 1310.53 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT | 13.46 | 0.00 | 01-JAN-00:15 | 2425.91 | 14-SEP-13:15 |
EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F3 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F4 SW APARTMENT | 18.30 | 0.04 | 05-MAY-08:45 | 3349.87 | 02-SEP-17:30 |
Heating:EnergyTransfer:Zone:F4 SW APARTMENT | 5.45 | 0.00 | 01-JAN-11:30 | 2846.98 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT | 12.84 | 0.00 | 01-JAN-00:15 | 3349.87 | 02-SEP-17:30 |
EnergyTransfer:Zone:F4 NW APARTMENT | 17.73 | 0.04 | 22-APR-01:15 | 3094.21 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F4 NW APARTMENT | 10.27 | 0.00 | 06-JAN-15:15 | 3094.21 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT | 7.46 | 0.00 | 01-JAN-00:15 | 2980.12 | 27-JUN-19:00 |
EnergyTransfer:Zone:F4 SE APARTMENT | 18.82 | 0.00 | 12-DEC-11:30 | 3171.39 | 12-SEP-13:30 |
Heating:EnergyTransfer:Zone:F4 SE APARTMENT | 5.41 | 0.00 | 01-JAN-10:00 | 2805.64 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT | 13.41 | 0.00 | 01-JAN-00:15 | 3171.39 | 12-SEP-13:30 |
EnergyTransfer:Zone:F4 NE APARTMENT | 18.23 | 0.02 | 19-MAR-14:00 | 3057.86 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F4 NE APARTMENT | 10.16 | 0.00 | 27-JAN-12:00 | 3057.86 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT | 8.07 | 0.00 | 01-JAN-00:15 | 2271.60 | 21-JUL-10:00 |
EnergyTransfer:Zone:F4 N1 APARTMENT | 10.61 | 0.01 | 13-JUN-20:30 | 1700.98 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT | 3.86 | 0.00 | 02-JAN-22:00 | 1700.98 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT | 6.75 | 0.00 | 01-JAN-00:15 | 1546.92 | 16-JUL-19:00 |
EnergyTransfer:Zone:F4 N2 APARTMENT | 10.62 | 0.03 | 09-AUG-07:45 | 1699.73 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT | 3.86 | 0.00 | 02-JAN-22:00 | 1699.73 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT | 6.76 | 0.00 | 01-JAN-00:15 | 1530.06 | 16-JUL-19:00 |
EnergyTransfer:Zone:F4 S1 APARTMENT | 14.95 | 0.16 | 04-JAN-00:45 | 2430.48 | 14-SEP-13:15 |
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT | 1.34 | 0.00 | 01-JAN-09:30 | 1424.89 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT | 13.61 | 0.00 | 01-JAN-00:15 | 2430.48 | 14-SEP-13:15 |
EnergyTransfer:Zone:F4 S2 APARTMENT | 14.97 | 0.05 | 03-JAN-23:15 | 2441.52 | 14-SEP-13:15 |
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT | 1.34 | 0.00 | 01-JAN-09:30 | 1423.01 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT | 13.63 | 0.00 | 01-JAN-00:15 | 2441.52 | 14-SEP-13:15 |
EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F4 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M SW APARTMENT | 18.58 | 0.00 | 02-OCT-20:00 | 3399.82 | 02-SEP-17:30 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 5.77 | 0.00 | 01-JAN-11:30 | 3011.30 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 12.82 | 0.00 | 01-JAN-00:15 | 3399.82 | 02-SEP-17:30 |
EnergyTransfer:Zone:M NW APARTMENT | 18.13 | 0.00 | 19-MAY-11:30 | 3261.45 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 10.61 | 0.00 | 06-JAN-15:15 | 3261.45 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 7.52 | 0.00 | 01-JAN-00:15 | 3006.83 | 28-JUN-18:00 |
EnergyTransfer:Zone:M SE APARTMENT | 19.10 | 0.02 | 02-NOV-12:00 | 3206.10 | 12-SEP-13:30 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 5.73 | 0.00 | 01-JAN-10:00 | 2971.49 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 13.36 | 0.00 | 01-JAN-00:15 | 3206.10 | 12-SEP-13:30 |
EnergyTransfer:Zone:M NE APARTMENT | 18.61 | 0.03 | 21-APR-10:45 | 3223.78 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 10.48 | 0.00 | 05-JAN-10:30 | 3223.78 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 8.13 | 0.00 | 01-JAN-00:15 | 2300.76 | 21-JUL-10:00 |
EnergyTransfer:Zone:M N1 APARTMENT | 10.86 | 0.01 | 15-JUL-07:45 | 1792.28 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 3.96 | 0.00 | 04-JAN-10:45 | 1792.28 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 6.90 | 0.00 | 01-JAN-00:15 | 1585.17 | 05-JUL-18:15 |
EnergyTransfer:Zone:M N2 APARTMENT | 10.86 | 0.02 | 24-MAY-14:30 | 1791.01 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 3.96 | 0.00 | 04-JAN-10:45 | 1791.01 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 6.90 | 0.00 | 01-JAN-00:15 | 1570.66 | 05-JUL-18:15 |
EnergyTransfer:Zone:M S1 APARTMENT | 15.13 | 0.08 | 12-APR-17:15 | 2464.50 | 14-SEP-13:15 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 1.43 | 0.00 | 01-JAN-09:30 | 1516.28 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 13.70 | 0.00 | 01-JAN-00:15 | 2464.50 | 14-SEP-13:15 |
EnergyTransfer:Zone:M S2 APARTMENT | 15.14 | 0.06 | 20-SEP-16:45 | 2475.26 | 14-SEP-13:15 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 1.43 | 0.00 | 01-JAN-09:30 | 1514.55 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 13.71 | 0.00 | 01-JAN-00:15 | 2475.26 | 14-SEP-13:15 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F6 SW APARTMENT | 18.59 | 0.02 | 26-JAN-13:45 | 3365.94 | 02-SEP-17:30 |
Heating:EnergyTransfer:Zone:F6 SW APARTMENT | 6.51 | 0.00 | 01-JAN-11:30 | 3206.46 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT | 12.08 | 0.00 | 01-JAN-00:15 | 3365.94 | 02-SEP-17:30 |
EnergyTransfer:Zone:F6 NW APARTMENT | 18.69 | 0.01 | 19-OCT-04:15 | 3457.80 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F6 NW APARTMENT | 11.62 | 0.00 | 06-JAN-15:15 | 3457.80 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT | 7.07 | 0.00 | 01-JAN-00:15 | 2968.21 | 28-JUN-18:00 |
EnergyTransfer:Zone:F6 SE APARTMENT | 19.07 | 0.06 | 06-DEC-03:15 | 3178.01 | 12-SEP-13:30 |
Heating:EnergyTransfer:Zone:F6 SE APARTMENT | 6.46 | 0.00 | 01-JAN-10:00 | 3165.91 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT | 12.60 | 0.00 | 01-JAN-00:15 | 3178.01 | 12-SEP-13:30 |
EnergyTransfer:Zone:F6 NE APARTMENT | 19.12 | 0.09 | 21-APR-02:00 | 3418.95 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F6 NE APARTMENT | 11.47 | 0.00 | 27-JAN-12:15 | 3418.95 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT | 7.65 | 0.00 | 01-JAN-00:15 | 2265.15 | 21-JUL-10:00 |
EnergyTransfer:Zone:F6 N1 APARTMENT | 10.97 | 0.01 | 20-OCT-22:15 | 1921.19 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT | 4.56 | 0.00 | 02-JAN-22:00 | 1921.19 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT | 6.41 | 0.00 | 01-JAN-00:15 | 1556.92 | 05-JUL-18:15 |
EnergyTransfer:Zone:F6 N2 APARTMENT | 10.99 | 0.01 | 03-FEB-17:30 | 1919.89 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT | 4.56 | 0.00 | 02-JAN-22:00 | 1919.89 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT | 6.42 | 0.00 | 01-JAN-00:15 | 1541.97 | 16-JUN-19:00 |
EnergyTransfer:Zone:F6 S1 APARTMENT | 14.60 | 0.09 | 22-DEC-10:00 | 2433.55 | 14-SEP-13:15 |
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT | 1.70 | 0.00 | 01-JAN-09:30 | 1642.19 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT | 12.91 | 0.00 | 01-JAN-00:15 | 2433.55 | 14-SEP-13:15 |
EnergyTransfer:Zone:F6 S2 APARTMENT | 14.62 | 0.01 | 21-APR-01:00 | 2444.28 | 14-SEP-13:15 |
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT | 1.70 | 0.00 | 01-JAN-09:30 | 1640.50 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT | 12.92 | 0.00 | 01-JAN-00:15 | 2444.28 | 14-SEP-13:15 |
EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F6 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F7 SW APARTMENT | 18.73 | 0.01 | 02-OCT-04:00 | 3367.50 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F7 SW APARTMENT | 7.12 | 0.00 | 01-JAN-11:30 | 3367.50 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT | 11.61 | 0.00 | 01-JAN-00:15 | 3361.83 | 08-AUG-16:30 |
EnergyTransfer:Zone:F7 NW APARTMENT | 19.20 | 0.02 | 10-SEP-00:45 | 3617.38 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F7 NW APARTMENT | 12.39 | 0.00 | 06-JAN-15:30 | 3617.38 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT | 6.81 | 0.00 | 01-JAN-00:15 | 2963.97 | 28-JUN-18:00 |
EnergyTransfer:Zone:F7 SE APARTMENT | 19.20 | 0.00 | 03-NOV-19:30 | 3326.41 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F7 SE APARTMENT | 7.07 | 0.00 | 01-JAN-10:00 | 3326.41 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT | 12.12 | 0.00 | 01-JAN-00:15 | 3172.01 | 12-SEP-13:30 |
EnergyTransfer:Zone:F7 NE APARTMENT | 19.59 | 0.00 | 02-OCT-00:30 | 3577.64 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F7 NE APARTMENT | 12.21 | 0.00 | 27-JAN-12:15 | 3577.64 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT | 7.37 | 0.00 | 01-JAN-00:15 | 2256.11 | 19-JUN-10:30 |
EnergyTransfer:Zone:F7 N1 APARTMENT | 11.12 | 0.02 | 28-AUG-10:45 | 2022.62 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT | 5.00 | 0.00 | 02-JAN-22:00 | 2022.62 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT | 6.12 | 0.00 | 01-JAN-00:15 | 1554.84 | 16-JUN-19:00 |
EnergyTransfer:Zone:F7 N2 APARTMENT | 11.14 | 0.01 | 13-AUG-18:00 | 2021.31 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT | 5.01 | 0.00 | 02-JAN-22:00 | 2021.31 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT | 6.14 | 0.00 | 01-JAN-00:15 | 1540.82 | 16-JUN-19:00 |
EnergyTransfer:Zone:F7 S1 APARTMENT | 14.32 | 0.02 | 11-MAY-13:00 | 2416.86 | 14-SEP-13:30 |
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT | 1.94 | 0.00 | 01-JAN-09:30 | 1745.20 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT | 12.38 | 0.00 | 01-JAN-00:15 | 2416.86 | 14-SEP-13:30 |
EnergyTransfer:Zone:F7 S2 APARTMENT | 14.34 | 0.07 | 17-JUL-08:15 | 2427.46 | 14-SEP-13:30 |
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT | 1.94 | 0.00 | 01-JAN-09:30 | 1743.56 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT | 12.40 | 0.00 | 01-JAN-00:15 | 2427.46 | 14-SEP-13:30 |
EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F7 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F8 SW APARTMENT | 18.98 | 0.00 | 28-AUG-19:15 | 3522.36 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F8 SW APARTMENT | 7.76 | 0.00 | 01-JAN-11:30 | 3522.36 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT | 11.21 | 0.00 | 01-JAN-00:15 | 3369.01 | 08-AUG-16:30 |
EnergyTransfer:Zone:F8 NW APARTMENT | 19.79 | 0.02 | 11-JUN-05:00 | 3768.78 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F8 NW APARTMENT | 13.16 | 0.00 | 06-JAN-15:30 | 3768.78 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT | 6.63 | 0.00 | 01-JAN-00:15 | 2964.36 | 28-JUN-18:00 |
EnergyTransfer:Zone:F8 SE APARTMENT | 19.44 | 0.01 | 09-APR-23:15 | 3480.52 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F8 SE APARTMENT | 7.71 | 0.00 | 01-JAN-10:00 | 3480.52 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT | 11.73 | 0.00 | 01-JAN-00:15 | 3176.24 | 12-SEP-13:30 |
EnergyTransfer:Zone:F8 NE APARTMENT | 20.14 | 0.00 | 24-OCT-16:00 | 3728.32 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F8 NE APARTMENT | 12.97 | 0.00 | 27-JAN-12:30 | 3728.32 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT | 7.17 | 0.00 | 01-JAN-00:15 | 2262.62 | 19-JUN-10:30 |
EnergyTransfer:Zone:F8 N1 APARTMENT | 11.40 | 0.02 | 28-JUL-17:30 | 2121.79 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT | 5.49 | 0.00 | 02-JAN-22:00 | 2121.79 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT | 5.92 | 0.00 | 01-JAN-00:15 | 1563.04 | 16-JUN-19:00 |
EnergyTransfer:Zone:F8 N2 APARTMENT | 11.42 | 0.02 | 13-OCT-15:45 | 2120.46 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT | 5.49 | 0.00 | 02-JAN-22:00 | 2120.46 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT | 5.93 | 0.00 | 01-JAN-00:15 | 1547.86 | 16-JUN-19:00 |
EnergyTransfer:Zone:F8 S1 APARTMENT | 14.12 | 0.07 | 18-DEC-23:30 | 2419.24 | 14-SEP-13:30 |
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT | 2.21 | 0.00 | 01-JAN-09:30 | 1848.85 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT | 11.90 | 0.00 | 01-JAN-00:15 | 2419.24 | 14-SEP-13:30 |
EnergyTransfer:Zone:F8 S2 APARTMENT | 14.13 | 0.01 | 12-NOV-04:30 | 2429.88 | 14-SEP-13:30 |
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT | 2.22 | 0.00 | 01-JAN-09:30 | 1847.20 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT | 11.92 | 0.00 | 01-JAN-00:15 | 2429.88 | 14-SEP-13:30 |
EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F8 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:F9 SW APARTMENT | 19.92 | 0.01 | 27-SEP-09:00 | 3783.62 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F9 SW APARTMENT | 9.13 | 0.00 | 01-JAN-11:45 | 3783.62 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT | 10.79 | 0.00 | 01-JAN-00:15 | 3459.13 | 08-AUG-16:30 |
EnergyTransfer:Zone:F9 NW APARTMENT | 21.38 | 0.01 | 11-JUN-15:15 | 4017.12 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F9 NW APARTMENT | 14.83 | 0.00 | 06-JAN-16:15 | 4017.12 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT | 6.55 | 0.00 | 01-JAN-00:15 | 3045.61 | 28-JUN-18:00 |
EnergyTransfer:Zone:F9 SE APARTMENT | 20.31 | 0.00 | 31-MAR-16:00 | 3740.42 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F9 SE APARTMENT | 9.04 | 0.00 | 01-JAN-11:30 | 3740.42 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT | 11.27 | 0.00 | 01-JAN-00:15 | 3236.31 | 12-SEP-13:30 |
EnergyTransfer:Zone:F9 NE APARTMENT | 21.60 | 0.00 | 11-MAY-20:30 | 3975.49 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F9 NE APARTMENT | 14.56 | 0.00 | 27-JAN-12:45 | 3975.49 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT | 7.04 | 0.00 | 01-JAN-00:15 | 2295.44 | 19-JUN-10:30 |
EnergyTransfer:Zone:F9 N1 APARTMENT | 12.43 | 0.02 | 01-OCT-14:30 | 2314.29 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT | 6.72 | 0.00 | 04-JAN-22:00 | 2314.29 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT | 5.71 | 0.00 | 01-JAN-00:15 | 1646.83 | 16-JUN-19:00 |
EnergyTransfer:Zone:F9 N2 APARTMENT | 12.45 | 0.01 | 15-OCT-01:30 | 2312.94 | 25-DEC-12:00 |
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT | 6.73 | 0.00 | 04-JAN-22:00 | 2312.94 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT | 5.72 | 0.00 | 01-JAN-00:15 | 1631.57 | 16-JUN-19:00 |
EnergyTransfer:Zone:F9 S1 APARTMENT | 14.08 | 0.03 | 15-SEP-09:45 | 2468.88 | 14-SEP-13:30 |
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT | 2.90 | 0.00 | 01-JAN-09:45 | 2055.85 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT | 11.17 | 0.00 | 01-JAN-00:15 | 2468.88 | 14-SEP-13:30 |
EnergyTransfer:Zone:F9 S2 APARTMENT | 14.10 | 0.07 | 07-NOV-10:45 | 2480.84 | 14-SEP-13:30 |
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT | 2.91 | 0.00 | 01-JAN-09:45 | 2054.06 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT | 11.19 | 0.00 | 01-JAN-00:15 | 2480.84 | 14-SEP-13:30 |
EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:F9 CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:T SW APARTMENT | 28.10 | 0.00 | 09-NOV-19:45 | 4538.45 | 25-DEC-09:00 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 16.86 | 0.00 | 01-JAN-11:45 | 4538.45 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 11.23 | 0.00 | 01-JAN-00:15 | 4257.90 | 11-SEP-15:15 |
EnergyTransfer:Zone:T NW APARTMENT | 28.95 | 0.04 | 02-MAR-14:15 | 4667.56 | 25-DEC-09:00 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 21.93 | 0.00 | 06-JAN-15:15 | 4667.56 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 7.02 | 0.00 | 01-JAN-00:15 | 3740.27 | 18-JUL-18:30 |
EnergyTransfer:Zone:T SE APARTMENT | 27.96 | 0.01 | 16-APR-08:00 | 4491.54 | 25-DEC-09:00 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 16.54 | 0.00 | 01-JAN-11:30 | 4491.54 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 11.41 | 0.00 | 01-JAN-00:15 | 3982.83 | 12-SEP-13:30 |
EnergyTransfer:Zone:T NE APARTMENT | 28.50 | 0.01 | 10-APR-22:15 | 4622.01 | 25-DEC-09:00 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 21.33 | 0.00 | 27-JAN-12:30 | 4622.01 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 7.17 | 0.00 | 01-JAN-00:15 | 2938.76 | 18-JUL-10:30 |
EnergyTransfer:Zone:T N1 APARTMENT | 18.15 | 0.05 | 19-SEP-00:30 | 2953.30 | 25-DEC-09:00 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 12.70 | 0.00 | 27-JAN-12:15 | 2953.30 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 5.45 | 0.00 | 01-JAN-00:15 | 2227.26 | 27-JUN-19:00 |
EnergyTransfer:Zone:T N2 APARTMENT | 18.17 | 0.00 | 14-JUL-01:00 | 2952.52 | 25-DEC-09:00 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 12.71 | 0.00 | 27-JAN-12:15 | 2952.52 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 5.46 | 0.00 | 01-JAN-00:15 | 2224.87 | 27-JUN-19:00 |
EnergyTransfer:Zone:T S1 APARTMENT | 18.30 | 0.01 | 16-OCT-02:15 | 3330.97 | 12-SEP-13:15 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 8.33 | 0.00 | 01-JAN-11:15 | 2804.37 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 9.96 | 0.00 | 01-JAN-00:15 | 3330.97 | 12-SEP-13:15 |
EnergyTransfer:Zone:T S2 APARTMENT | 18.34 | 0.02 | 03-NOV-08:45 | 3342.11 | 12-SEP-13:15 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 8.34 | 0.00 | 01-JAN-11:00 | 2803.26 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 9.99 | 0.00 | 01-JAN-00:15 | 3342.11 | 12-SEP-13:15 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Plant | 1612.94 | 510.95 | 19-AUG-01:15 | 234824.38 | 25-DEC-09:00 |
WaterSystems:EnergyTransfer | 975.07 | 510.95 | 19-AUG-01:15 | 65783.42 | 22-FEB-08:00 |
sub cat:WaterSystems:EnergyTransfer | 975.07 | 510.95 | 19-AUG-01:15 | 65783.42 | 22-FEB-08:00 |
EnergyTransfer:HVAC | 1597.50 | 0.00 | 26-MAR-20:45 | 260118.25 | 25-DEC-09:00 |
CoolingCoils:EnergyTransfer | 704.01 | 0.00 | 01-JAN-00:15 | 214260.53 | 30-JUN-15:15 |
HeatingCoils:EnergyTransfer | 893.49 | 0.00 | 18-MAR-15:15 | 260118.25 | 25-DEC-09:00 |
PlantLoopHeatingDemand:HVAC | 683.83 | 0.00 | 18-MAR-15:15 | 179984.83 | 25-DEC-09:00 |
HeatingCoils:PlantLoopHeatingDemand | 683.83 | 0.00 | 18-MAR-15:15 | 179984.83 | 25-DEC-09:00 |
Boilers:EnergyTransfer | 637.87 | 0.00 | 06-JAN-15:15 | 177071.99 | 25-DEC-09:15 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:13
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 7.432 | -7.131 | 0.000 | 0.000 | 3.863 | 1.087 | 12.213 | 21.093 | 0.000 | 0.150 | 0.000 | 0.000 | -13.486 | 0.000 | -7.779 | -17.442 |
G NW APARTMENT | 11.712 | -4.223 | 0.000 | 0.000 | 3.900 | 1.087 | 12.213 | 9.591 | 0.000 | 0.151 | 0.000 | 0.000 | -14.093 | 0.000 | -7.440 | -12.896 |
OFFICE | 5.510 | -15.794 | 0.000 | 0.000 | 0.525 | 29.882 | 9.495 | 20.983 | 0.000 | 0.098 | 0.000 | 0.000 | -13.379 | 0.000 | -5.195 | -32.126 |
G NE APARTMENT | 11.579 | -4.494 | 0.000 | 0.000 | 3.914 | 1.087 | 12.213 | 9.576 | 0.000 | 0.151 | 0.000 | 0.000 | -13.743 | 0.000 | -7.457 | -12.826 |
G N1 APARTMENT | 6.694 | -3.536 | 0.000 | 0.000 | 3.919 | 1.087 | 12.213 | 3.010 | 0.000 | 0.112 | 0.000 | 0.000 | -8.881 | 0.000 | -5.211 | -9.406 |
G N2 APARTMENT | 6.700 | -3.534 | 0.000 | 0.000 | 3.919 | 1.087 | 12.213 | 3.007 | 0.000 | 0.112 | 0.000 | 0.000 | -8.878 | 0.000 | -5.216 | -9.411 |
G S1 APARTMENT | 2.931 | -7.042 | 0.000 | 0.000 | 3.866 | 1.087 | 12.213 | 14.623 | 0.000 | 0.111 | 0.000 | 0.000 | -8.227 | 0.000 | -5.621 | -13.941 |
G S2 APARTMENT | 2.784 | -7.274 | 0.000 | 0.000 | 3.861 | 1.087 | 12.213 | 14.602 | 0.000 | 0.111 | 0.000 | 0.000 | -8.243 | 0.000 | -5.665 | -13.475 |
F2 SW APARTMENT | 5.266 | -12.071 | 0.000 | 0.000 | 3.796 | 1.087 | 12.213 | 20.445 | 0.000 | 0.202 | 0.000 | 0.000 | -14.260 | 0.000 | -10.698 | -5.979 |
F2 NW APARTMENT | 9.989 | -6.942 | 0.000 | 0.000 | 3.860 | 1.087 | 12.213 | 9.150 | 0.000 | 0.203 | 0.000 | 0.000 | -14.771 | 0.000 | -10.261 | -4.527 |
F2 SE APARTMENT | 4.568 | -13.766 | 0.000 | 0.000 | 3.788 | 1.087 | 12.213 | 20.408 | 0.000 | 0.202 | 0.000 | 0.000 | -14.027 | 0.000 | -10.816 | -3.656 |
F2 NE APARTMENT | 9.873 | -7.493 | 0.000 | 0.000 | 3.875 | 1.087 | 12.213 | 9.174 | 0.000 | 0.203 | 0.000 | 0.000 | -14.383 | 0.000 | -10.240 | -4.308 |
F2 N1 APARTMENT | 4.115 | -5.898 | 0.000 | 0.000 | 3.877 | 1.087 | 12.213 | 2.785 | 0.000 | 0.147 | 0.000 | 0.000 | -9.357 | 0.000 | -7.116 | -1.852 |
F2 N2 APARTMENT | 4.118 | -5.907 | 0.000 | 0.000 | 3.878 | 1.087 | 12.213 | 2.783 | 0.000 | 0.147 | 0.000 | 0.000 | -9.353 | 0.000 | -7.117 | -1.847 |
F2 S1 APARTMENT | 1.416 | -12.111 | 0.000 | 0.000 | 3.783 | 1.087 | 12.213 | 14.218 | 0.000 | 0.146 | 0.000 | 0.000 | -8.718 | 0.000 | -7.662 | -4.372 |
F2 S2 APARTMENT | 1.392 | -12.247 | 0.000 | 0.000 | 3.780 | 1.087 | 12.213 | 14.211 | 0.000 | 0.146 | 0.000 | 0.000 | -8.725 | 0.000 | -7.678 | -4.178 |
F3 SW APARTMENT | 5.117 | -12.867 | 0.000 | 0.000 | 3.786 | 1.087 | 12.213 | 20.203 | 0.000 | 0.243 | 0.000 | 0.000 | -14.489 | 0.000 | -12.302 | -2.989 |
F3 NW APARTMENT | 9.819 | -7.439 | 0.000 | 0.000 | 3.853 | 1.087 | 12.213 | 8.995 | 0.000 | 0.246 | 0.000 | 0.000 | -14.999 | 0.000 | -11.831 | -1.944 |
F3 SE APARTMENT | 4.968 | -13.593 | 0.000 | 0.000 | 3.790 | 1.087 | 12.213 | 20.245 | 0.000 | 0.244 | 0.000 | 0.000 | -14.150 | 0.000 | -12.339 | -2.464 |
F3 NE APARTMENT | 9.715 | -8.033 | 0.000 | 0.000 | 3.868 | 1.087 | 12.213 | 9.042 | 0.000 | 0.246 | 0.000 | 0.000 | -14.596 | 0.000 | -11.799 | -1.740 |
F3 N1 APARTMENT | 3.720 | -6.612 | 0.000 | 0.000 | 3.867 | 1.087 | 12.213 | 2.715 | 0.000 | 0.179 | 0.511 | 0.000 | -9.516 | 0.000 | -8.162 | -0.000 |
F3 N2 APARTMENT | 3.722 | -6.621 | 0.000 | 0.000 | 3.867 | 1.087 | 12.213 | 2.713 | 0.000 | 0.179 | 0.515 | 0.000 | -9.512 | 0.000 | -8.163 | -0.000 |
F3 S1 APARTMENT | 1.258 | -13.409 | 0.000 | 0.000 | 3.762 | 1.087 | 12.213 | 14.059 | 0.000 | 0.178 | 0.000 | 0.000 | -8.884 | 0.000 | -8.749 | -1.515 |
F3 S2 APARTMENT | 1.256 | -13.457 | 0.000 | 0.000 | 3.762 | 1.087 | 12.213 | 14.056 | 0.000 | 0.178 | 0.001 | 0.000 | -8.885 | 0.000 | -8.757 | -1.452 |
F4 SW APARTMENT | 5.451 | -12.845 | 0.000 | 0.000 | 3.787 | 1.087 | 12.213 | 20.065 | 0.000 | 0.266 | 0.000 | 0.000 | -14.595 | 0.000 | -13.339 | -2.089 |
F4 NW APARTMENT | 10.273 | -7.461 | 0.000 | 0.000 | 3.853 | 1.087 | 12.213 | 8.912 | 0.000 | 0.269 | 0.000 | 0.000 | -15.119 | 0.000 | -12.854 | -1.174 |
F4 SE APARTMENT | 5.409 | -13.413 | 0.000 | 0.000 | 3.793 | 1.087 | 12.213 | 20.131 | 0.000 | 0.267 | 0.000 | 0.000 | -14.230 | 0.000 | -13.359 | -1.898 |
F4 NE APARTMENT | 10.159 | -8.069 | 0.000 | 0.000 | 3.868 | 1.087 | 12.213 | 8.972 | 0.000 | 0.268 | 0.000 | 0.000 | -14.707 | 0.000 | -12.817 | -0.973 |
F4 N1 APARTMENT | 3.860 | -6.751 | 0.000 | 0.000 | 3.864 | 1.087 | 12.213 | 2.680 | 0.000 | 0.195 | 1.244 | 0.000 | -9.601 | 0.000 | -8.790 | -0.000 |
F4 N2 APARTMENT | 3.864 | -6.759 | 0.000 | 0.000 | 3.865 | 1.087 | 12.213 | 2.679 | 0.000 | 0.194 | 1.246 | 0.000 | -9.597 | 0.000 | -8.790 | -0.000 |
F4 S1 APARTMENT | 1.343 | -13.607 | 0.000 | 0.000 | 3.759 | 1.087 | 12.213 | 13.970 | 0.000 | 0.193 | 0.000 | 0.000 | -8.958 | 0.000 | -9.389 | -0.610 |
F4 S2 APARTMENT | 1.343 | -13.626 | 0.000 | 0.000 | 3.759 | 1.087 | 12.213 | 13.968 | 0.000 | 0.193 | 0.001 | 0.000 | -8.957 | 0.000 | -9.394 | -0.586 |
M SW APARTMENT | 5.765 | -12.818 | 0.000 | 0.000 | 3.788 | 1.087 | 12.213 | 19.959 | 0.000 | 0.284 | 0.000 | 0.000 | -14.678 | 0.000 | -14.314 | -1.286 |
M NW APARTMENT | 10.610 | -7.518 | 0.000 | 0.000 | 3.854 | 1.087 | 12.213 | 8.848 | 0.000 | 0.287 | 0.000 | 0.000 | -15.216 | 0.000 | -13.805 | -0.359 |
M SE APARTMENT | 5.735 | -13.364 | 0.000 | 0.000 | 3.795 | 1.087 | 12.213 | 20.036 | 0.000 | 0.285 | 0.001 | 0.000 | -14.303 | 0.000 | -14.331 | -1.153 |
M NE APARTMENT | 10.478 | -8.131 | 0.000 | 0.000 | 3.869 | 1.087 | 12.213 | 8.918 | 0.000 | 0.287 | 0.001 | 0.000 | -14.799 | 0.000 | -13.766 | -0.155 |
M N1 APARTMENT | 3.957 | -6.899 | 0.000 | 0.000 | 3.863 | 1.087 | 12.213 | 2.655 | 0.000 | 0.207 | 1.999 | 0.000 | -9.669 | 0.000 | -9.413 | -0.000 |
M N2 APARTMENT | 3.955 | -6.904 | 0.000 | 0.000 | 3.864 | 1.087 | 12.213 | 2.653 | 0.000 | 0.206 | 2.003 | 0.000 | -9.665 | 0.000 | -9.413 | -0.000 |
M S1 APARTMENT | 1.427 | -13.699 | 0.000 | 0.000 | 3.759 | 1.087 | 12.213 | 13.903 | 0.000 | 0.205 | 0.150 | 0.000 | -9.012 | 0.000 | -10.032 | -0.000 |
M S2 APARTMENT | 1.430 | -13.713 | 0.000 | 0.000 | 3.759 | 1.087 | 12.213 | 13.900 | 0.000 | 0.205 | 0.166 | 0.000 | -9.010 | 0.000 | -10.037 | -0.000 |
F6 SW APARTMENT | 6.506 | -12.082 | 0.000 | 0.000 | 3.797 | 1.087 | 12.213 | 19.909 | 0.000 | 0.300 | 0.000 | 0.000 | -14.684 | 0.000 | -15.088 | -1.959 |
F6 NW APARTMENT | 11.620 | -7.066 | 0.000 | 0.000 | 3.862 | 1.087 | 12.213 | 8.829 | 0.000 | 0.304 | 0.000 | 0.000 | -15.234 | 0.000 | -14.547 | -1.066 |
F6 SE APARTMENT | 6.463 | -12.603 | 0.000 | 0.000 | 3.804 | 1.087 | 12.213 | 19.994 | 0.000 | 0.301 | 0.000 | 0.000 | -14.304 | 0.000 | -15.108 | -1.847 |
F6 NE APARTMENT | 11.467 | -7.651 | 0.000 | 0.000 | 3.876 | 1.087 | 12.213 | 8.906 | 0.000 | 0.303 | 0.000 | 0.000 | -14.814 | 0.000 | -14.510 | -0.875 |
F6 N1 APARTMENT | 4.555 | -6.412 | 0.000 | 0.000 | 3.871 | 1.087 | 12.213 | 2.654 | 0.000 | 0.218 | 1.362 | 0.000 | -9.679 | 0.000 | -9.868 | -0.000 |
F6 N2 APARTMENT | 4.562 | -6.425 | 0.000 | 0.000 | 3.872 | 1.087 | 12.213 | 2.652 | 0.000 | 0.218 | 1.365 | 0.000 | -9.676 | 0.000 | -9.868 | -0.000 |
F6 S1 APARTMENT | 1.696 | -12.907 | 0.000 | 0.000 | 3.770 | 1.087 | 12.213 | 13.872 | 0.000 | 0.217 | 0.000 | 0.000 | -9.011 | 0.000 | -10.517 | -0.419 |
F6 S2 APARTMENT | 1.700 | -12.921 | 0.000 | 0.000 | 3.770 | 1.087 | 12.213 | 13.870 | 0.000 | 0.217 | 0.000 | 0.000 | -9.009 | 0.000 | -10.522 | -0.404 |
F7 SW APARTMENT | 7.122 | -11.608 | 0.000 | 0.000 | 3.804 | 1.087 | 12.213 | 19.861 | 0.000 | 0.314 | 0.000 | 0.000 | -14.700 | 0.000 | -15.776 | -2.315 |
F7 NW APARTMENT | 12.390 | -6.807 | 0.000 | 0.000 | 3.867 | 1.087 | 12.213 | 8.806 | 0.000 | 0.318 | 0.000 | 0.000 | -15.262 | 0.000 | -15.214 | -1.397 |
F7 SE APARTMENT | 7.074 | -12.124 | 0.000 | 0.000 | 3.811 | 1.087 | 12.213 | 19.951 | 0.000 | 0.315 | 0.001 | 0.000 | -14.317 | 0.000 | -15.798 | -2.211 |
F7 NE APARTMENT | 12.213 | -7.372 | 0.000 | 0.000 | 3.882 | 1.087 | 12.213 | 8.889 | 0.000 | 0.316 | 0.000 | 0.000 | -14.839 | 0.000 | -15.177 | -1.211 |
F7 N1 APARTMENT | 5.000 | -6.123 | 0.000 | 0.000 | 3.877 | 1.087 | 12.213 | 2.649 | 0.000 | 0.227 | 1.045 | 0.000 | -9.696 | 0.000 | -10.279 | -0.000 |
F7 N2 APARTMENT | 5.006 | -6.138 | 0.000 | 0.000 | 3.878 | 1.087 | 12.213 | 2.648 | 0.000 | 0.227 | 1.051 | 0.000 | -9.692 | 0.000 | -10.280 | -0.000 |
F7 S1 APARTMENT | 1.938 | -12.382 | 0.000 | 0.000 | 3.778 | 1.087 | 12.213 | 13.843 | 0.000 | 0.226 | 0.001 | 0.000 | -9.015 | 0.000 | -10.949 | -0.739 |
F7 S2 APARTMENT | 1.940 | -12.395 | 0.000 | 0.000 | 3.779 | 1.087 | 12.213 | 13.840 | 0.000 | 0.226 | 0.000 | 0.000 | -9.014 | 0.000 | -10.954 | -0.722 |
F8 SW APARTMENT | 7.764 | -11.213 | 0.000 | 0.000 | 3.810 | 1.087 | 12.213 | 19.820 | 0.000 | 0.327 | 0.000 | 0.000 | -14.712 | 0.000 | -16.417 | -2.678 |
F8 NW APARTMENT | 13.161 | -6.628 | 0.000 | 0.000 | 3.872 | 1.087 | 12.213 | 8.786 | 0.000 | 0.331 | 0.000 | 0.000 | -15.288 | 0.000 | -15.836 | -1.698 |
F8 SE APARTMENT | 7.710 | -11.730 | 0.000 | 0.000 | 3.817 | 1.087 | 12.213 | 19.915 | 0.000 | 0.328 | 0.001 | 0.000 | -14.326 | 0.000 | -16.442 | -2.570 |
F8 NE APARTMENT | 12.965 | -7.174 | 0.000 | 0.000 | 3.886 | 1.087 | 12.213 | 8.874 | 0.000 | 0.330 | 0.000 | 0.000 | -14.862 | 0.000 | -15.801 | -1.517 |
F8 N1 APARTMENT | 5.485 | -5.916 | 0.000 | 0.000 | 3.882 | 1.087 | 12.213 | 2.645 | 0.000 | 0.237 | 0.752 | 0.000 | -9.711 | 0.000 | -10.672 | -0.000 |
F8 N2 APARTMENT | 5.488 | -5.928 | 0.000 | 0.000 | 3.883 | 1.087 | 12.213 | 2.643 | 0.000 | 0.236 | 0.759 | 0.000 | -9.707 | 0.000 | -10.673 | -0.000 |
F8 S1 APARTMENT | 2.213 | -11.903 | 0.000 | 0.000 | 3.786 | 1.087 | 12.213 | 13.819 | 0.000 | 0.236 | 0.000 | 0.000 | -9.017 | 0.000 | -11.357 | -1.077 |
F8 S2 APARTMENT | 2.215 | -11.916 | 0.000 | 0.000 | 3.787 | 1.087 | 12.213 | 13.816 | 0.000 | 0.236 | 0.000 | 0.000 | -9.015 | 0.000 | -11.362 | -1.060 |
F9 SW APARTMENT | 9.127 | -10.790 | 0.000 | 0.000 | 3.818 | 1.087 | 12.213 | 19.810 | 0.000 | 0.338 | 0.000 | 0.000 | -14.684 | 0.000 | -16.957 | -3.961 |
F9 NW APARTMENT | 14.829 | -6.553 | 0.000 | 0.000 | 3.876 | 1.087 | 12.213 | 8.779 | 0.000 | 0.342 | 0.000 | 0.000 | -15.281 | 0.000 | -16.374 | -2.918 |
F9 SE APARTMENT | 9.040 | -11.273 | 0.000 | 0.000 | 3.825 | 1.087 | 12.213 | 19.909 | 0.000 | 0.339 | 0.000 | 0.000 | -14.297 | 0.000 | -16.988 | -3.853 |
F9 NE APARTMENT | 14.555 | -7.040 | 0.000 | 0.000 | 3.890 | 1.087 | 12.213 | 8.872 | 0.000 | 0.340 | 0.000 | 0.000 | -14.854 | 0.000 | -16.339 | -2.723 |
F9 N1 APARTMENT | 6.723 | -5.707 | 0.000 | 0.000 | 3.886 | 1.087 | 12.213 | 2.646 | 0.000 | 0.245 | 0.000 | 0.000 | -9.702 | 0.000 | -11.004 | -0.385 |
F9 N2 APARTMENT | 6.727 | -5.720 | 0.000 | 0.000 | 3.887 | 1.087 | 12.213 | 2.644 | 0.000 | 0.244 | 0.000 | 0.000 | -9.699 | 0.000 | -11.005 | -0.378 |
F9 S1 APARTMENT | 2.902 | -11.175 | 0.000 | 0.000 | 3.798 | 1.087 | 12.213 | 13.816 | 0.000 | 0.243 | 0.000 | 0.000 | -8.990 | 0.000 | -11.684 | -2.210 |
F9 S2 APARTMENT | 2.908 | -11.192 | 0.000 | 0.000 | 3.798 | 1.087 | 12.213 | 13.814 | 0.000 | 0.243 | 0.000 | 0.000 | -8.988 | 0.000 | -11.691 | -2.191 |
T SW APARTMENT | 16.862 | -11.233 | 0.000 | 0.000 | 3.854 | 1.087 | 12.213 | 19.572 | 0.000 | 0.348 | 0.000 | 0.000 | -14.088 | 0.000 | -17.460 | -11.154 |
T NW APARTMENT | 21.926 | -7.024 | 0.000 | 0.000 | 3.893 | 1.087 | 12.213 | 8.593 | 0.000 | 0.351 | 0.000 | 0.000 | -14.791 | 0.000 | -16.965 | -9.282 |
T SE APARTMENT | 16.544 | -11.411 | 0.000 | 0.000 | 3.861 | 1.087 | 12.213 | 19.714 | 0.000 | 0.348 | 0.000 | 0.000 | -13.739 | 0.000 | -17.468 | -11.148 |
T NE APARTMENT | 21.331 | -7.171 | 0.000 | 0.000 | 3.910 | 1.087 | 12.213 | 8.735 | 0.000 | 0.351 | 0.000 | 0.000 | -14.404 | 0.000 | -16.904 | -9.147 |
T N1 APARTMENT | 12.701 | -5.453 | 0.000 | 0.000 | 3.902 | 1.087 | 12.213 | 2.587 | 0.000 | 0.253 | 0.000 | 0.000 | -9.388 | 0.000 | -11.392 | -6.508 |
T N2 APARTMENT | 12.713 | -5.458 | 0.000 | 0.000 | 3.903 | 1.087 | 12.213 | 2.583 | 0.000 | 0.253 | 0.000 | 0.000 | -9.383 | 0.000 | -11.398 | -6.511 |
T S1 APARTMENT | 8.333 | -9.964 | 0.000 | 0.000 | 3.838 | 1.087 | 12.213 | 13.699 | 0.000 | 0.249 | 0.000 | 0.000 | -8.655 | 0.000 | -12.003 | -8.798 |
T S2 APARTMENT | 8.345 | -9.991 | 0.000 | 0.000 | 3.838 | 1.087 | 12.213 | 13.694 | 0.000 | 0.249 | 0.000 | 0.000 | -8.651 | 0.000 | -12.010 | -8.774 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 4.590 | 0.000 | 0.878 | 51.759 | 0.000 | -2.995 | 0.000 | -70.672 | -0.002 |
F2 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 2.040 | 0.000 | 0.012 | 0.000 | 0.000 | -1.803 | 0.000 | -1.334 | -15.355 |
F3 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 1.995 | 0.000 | 0.013 | 0.000 | 0.000 | -1.871 | 0.000 | -1.625 | -14.952 |
F4 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 1.973 | 0.000 | 0.014 | 0.000 | 0.000 | -1.899 | 0.000 | -1.833 | -14.694 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32.880 | 0.000 | 1.947 | 0.000 | 0.012 | 0.000 | 0.000 | -1.938 | 0.000 | -2.063 | -30.839 |
F6 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 1.957 | 0.000 | 0.016 | 0.000 | 0.000 | -1.912 | 0.000 | -2.122 | -14.379 |
F7 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 1.958 | 0.000 | 0.017 | 0.000 | 0.000 | -1.905 | 0.000 | -2.224 | -14.286 |
F8 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 1.956 | 0.000 | 0.018 | 0.000 | 0.000 | -1.903 | 0.000 | -2.322 | -14.189 |
F9 CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 0.000 | 1.957 | 0.000 | 0.018 | 0.000 | 0.000 | -1.895 | 0.000 | -2.404 | -14.115 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.440 | 8.151 | 1.914 | 0.000 | 0.008 | 0.000 | 0.000 | -1.833 | 0.000 | -2.544 | -22.136 |
Total Facility | 564.531 | -739.650 | 0.000 | 0.000 | 303.858 | 296.560 | 982.450 | 937.182 | 0.000 | 20.142 | 65.940 | 0.000 | -968.805 | 0.000 | -1016.918 | -445.282 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 02-SEP-17:30 | 0.00 | -2598.98 | 0.00 | 0.00 | 138.30 | 87.56 | 588.62 | 3107.88 | 0.00 | 48.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1372.19 |
G NW APARTMENT | 28-JUN-18:30 | 0.00 | -2254.62 | 0.00 | 0.00 | 141.66 | 103.77 | 547.42 | 3176.83 | 0.00 | 159.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1874.85 |
OFFICE | 12-SEP-13:45 | 0.00 | -3774.03 | 0.00 | 0.00 | 65.20 | 2345.88 | 588.62 | 3557.14 | 0.00 | 23.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2806.50 |
G NE APARTMENT | 07-AUG-09:30 | 0.00 | -1658.87 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 2582.98 | 0.00 | 173.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1557.45 |
G N1 APARTMENT | 27-JUN-19:30 | 0.00 | -1123.07 | 0.00 | 0.00 | 141.27 | 103.77 | 523.87 | 1041.76 | 0.00 | 103.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -791.11 |
G N2 APARTMENT | 27-JUN-19:30 | 0.00 | -1120.21 | 0.00 | 0.00 | 141.42 | 103.77 | 523.87 | 1042.43 | 0.00 | 106.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -797.74 |
G S1 APARTMENT | 14-SEP-13:15 | 0.00 | -1786.37 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3234.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -21.77 | -1863.12 |
G S2 APARTMENT | 14-SEP-13:30 | 0.00 | -1857.72 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3172.29 | 0.00 | 14.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1764.92 |
F2 SW APARTMENT | 02-SEP-17:30 | 0.00 | -3336.11 | 0.00 | 0.00 | 138.55 | 87.56 | 588.62 | 3070.38 | 0.00 | 69.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -618.95 |
F2 NW APARTMENT | 28-JUN-18:30 | 0.00 | -2950.95 | 0.00 | 0.00 | 141.34 | 103.77 | 547.42 | 3151.19 | 0.00 | 164.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1156.87 |
F2 SE APARTMENT | 13-SEP-12:45 | 0.00 | -3264.70 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 3762.72 | 0.00 | 190.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1130.64 |
F2 NE APARTMENT | 18-JUL-10:15 | 0.00 | -2203.65 | 0.00 | 0.00 | 40.75 | 12.97 | 412.03 | 2170.05 | 0.00 | 137.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -569.33 |
F2 N1 APARTMENT | 27-JUN-19:15 | 0.00 | -1497.00 | 0.00 | 0.00 | 141.40 | 103.77 | 523.87 | 1014.07 | 0.00 | 205.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -491.47 |
F2 N2 APARTMENT | 27-JUN-19:15 | 0.00 | -1479.38 | 0.00 | 0.00 | 141.41 | 103.77 | 523.87 | 1014.43 | 0.00 | 205.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -509.50 |
F2 S1 APARTMENT | 14-SEP-13:15 | 0.00 | -2356.32 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3204.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -30.73 | -1253.89 |
F2 S2 APARTMENT | 14-SEP-13:15 | 0.00 | -2382.85 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3204.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -30.40 | -1227.39 |
F3 SW APARTMENT | 02-SEP-17:30 | 0.00 | -3351.77 | 0.00 | 0.00 | 138.53 | 87.56 | 588.62 | 3051.24 | 0.00 | 82.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -596.49 |
F3 NW APARTMENT | 27-JUN-19:00 | 0.00 | -2974.92 | 0.00 | 0.00 | 141.72 | 103.77 | 547.42 | 2740.96 | 0.00 | 379.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -938.33 |
F3 SE APARTMENT | 12-SEP-13:30 | 0.00 | -3172.21 | 0.00 | 0.00 | 40.73 | 12.97 | 382.60 | 3595.79 | 0.00 | 233.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1093.30 |
F3 NE APARTMENT | 21-JUL-09:53 | 0.00 | -2244.61 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 2282.17 | 0.00 | 244.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -741.75 |
F3 N1 APARTMENT | 16-JUL-19:00 | 0.00 | -1533.85 | 0.00 | 0.00 | 141.81 | 103.77 | 547.42 | 770.58 | 0.00 | 219.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -248.89 |
F3 N2 APARTMENT | 16-JUL-19:00 | 0.00 | -1516.91 | 0.00 | 0.00 | 141.81 | 103.77 | 547.42 | 770.79 | 0.00 | 218.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -265.60 |
F3 S1 APARTMENT | 14-SEP-13:15 | 0.00 | -2412.81 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3187.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -36.55 | -1174.34 |
F3 S2 APARTMENT | 14-SEP-13:15 | 0.00 | -2425.77 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3187.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -36.52 | -1161.20 |
F4 SW APARTMENT | 02-SEP-17:30 | 0.00 | -3357.63 | 0.00 | 0.00 | 138.49 | 87.56 | 588.62 | 3037.25 | 0.00 | 91.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -585.59 |
F4 NW APARTMENT | 28-JUN-18:00 | 0.00 | -2979.81 | 0.00 | 0.00 | 141.04 | 87.56 | 588.62 | 3051.05 | 0.00 | 275.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1163.91 |
F4 SE APARTMENT | 12-SEP-13:30 | 0.00 | -3170.82 | 0.00 | 0.00 | 40.72 | 12.97 | 382.60 | 3584.48 | 0.00 | 241.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1091.11 |
F4 NE APARTMENT | 21-JUL-10:00 | 0.00 | -2273.07 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 2273.08 | 0.00 | 253.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -713.62 |
F4 N1 APARTMENT | 16-JUL-19:00 | 0.00 | -1546.12 | 0.00 | 0.00 | 141.81 | 103.77 | 547.42 | 767.28 | 0.00 | 228.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -242.40 |
F4 N2 APARTMENT | 16-JUL-19:00 | 0.00 | -1529.27 | 0.00 | 0.00 | 141.81 | 103.77 | 547.42 | 767.50 | 0.00 | 227.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -259.02 |
F4 S1 APARTMENT | 14-SEP-13:15 | 0.00 | -2430.30 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3174.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -41.12 | -1139.61 |
F4 S2 APARTMENT | 14-SEP-13:15 | 0.00 | -2441.35 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3174.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -41.17 | -1128.33 |
M SW APARTMENT | 02-SEP-17:30 | 0.00 | -3407.62 | 0.00 | 0.00 | 138.83 | 87.56 | 588.62 | 3026.69 | 0.00 | 99.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -533.78 |
M NW APARTMENT | 28-JUN-18:00 | 0.00 | -3006.76 | 0.00 | 0.00 | 140.97 | 87.56 | 588.62 | 3042.33 | 0.00 | 285.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1138.68 |
M SE APARTMENT | 12-SEP-13:30 | 0.00 | -3205.51 | 0.00 | 0.00 | 40.73 | 12.97 | 382.60 | 3574.56 | 0.00 | 249.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1054.52 |
M NE APARTMENT | 21-JUL-10:00 | 0.00 | -2302.27 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 2265.08 | 0.00 | 264.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -686.90 |
M N1 APARTMENT | 05-JUL-18:15 | 0.00 | -1584.80 | 0.00 | 0.00 | 141.81 | 103.77 | 547.42 | 355.34 | 0.00 | 377.16 | 59.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 05-JUL-18:15 | 0.00 | -1570.29 | 0.00 | 0.00 | 141.81 | 103.77 | 547.42 | 355.32 | 0.00 | 375.03 | 46.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | 14-SEP-13:15 | 0.00 | -2464.29 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3164.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -45.12 | -1090.92 |
M S2 APARTMENT | 14-SEP-13:15 | 0.00 | -2475.05 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3163.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -45.19 | -1079.90 |
F6 SW APARTMENT | 02-SEP-17:30 | 0.00 | -3373.58 | 0.00 | 0.00 | 138.88 | 87.56 | 588.62 | 3018.79 | 0.00 | 106.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -566.31 |
F6 NW APARTMENT | 28-JUN-18:00 | 0.00 | -2968.12 | 0.00 | 0.00 | 140.89 | 87.56 | 588.62 | 3036.49 | 0.00 | 294.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1179.67 |
F6 SE APARTMENT | 12-SEP-13:30 | 0.00 | -3177.41 | 0.00 | 0.00 | 40.74 | 12.97 | 382.60 | 3567.47 | 0.00 | 255.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1082.07 |
F6 NE APARTMENT | 21-JUL-10:00 | 0.00 | -2266.70 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 2259.86 | 0.00 | 272.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -725.35 |
F6 N1 APARTMENT | 05-JUL-18:15 | 0.00 | -1556.55 | 0.00 | 0.00 | 141.81 | 103.77 | 547.42 | 355.20 | 0.00 | 392.96 | 15.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 N2 APARTMENT | 05-JUL-18:15 | 0.00 | -1541.17 | 0.00 | 0.00 | 141.81 | 103.77 | 547.42 | 355.18 | 0.00 | 390.56 | 2.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 S1 APARTMENT | 14-SEP-13:15 | 0.00 | -2433.31 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3155.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -49.10 | -1109.76 |
F6 S2 APARTMENT | 14-SEP-13:15 | 0.00 | -2444.04 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3155.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -49.17 | -1098.76 |
F7 SW APARTMENT | 02-SEP-17:30 | 0.00 | -3362.72 | 0.00 | 0.00 | 138.95 | 87.56 | 588.62 | 3011.56 | 0.00 | 111.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -575.64 |
F7 NW APARTMENT | 28-JUN-18:00 | 0.00 | -2963.87 | 0.00 | 0.00 | 140.95 | 87.56 | 588.62 | 3031.20 | 0.00 | 303.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1187.92 |
F7 SE APARTMENT | 12-SEP-13:30 | 0.00 | -3171.40 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3560.66 | 0.00 | 261.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1087.01 |
F7 NE APARTMENT | 19-JUN-10:30 | 0.00 | -2255.93 | 0.00 | 0.00 | 40.75 | 12.97 | 412.03 | 2195.30 | 0.00 | 238.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -644.05 |
F7 N1 APARTMENT | 16-JUN-19:00 | 0.00 | -1553.04 | 0.00 | 0.00 | 140.53 | 103.77 | 547.42 | 61.50 | 0.00 | 470.64 | 229.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 N2 APARTMENT | 16-JUN-19:00 | 0.00 | -1539.03 | 0.00 | 0.00 | 140.42 | 103.77 | 547.42 | 61.32 | 0.00 | 464.46 | 221.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 S1 APARTMENT | 14-SEP-13:30 | 0.00 | -2416.23 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3082.43 | 0.00 | 13.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1115.97 |
F7 S2 APARTMENT | 14-SEP-13:30 | 0.00 | -2426.82 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3082.25 | 0.00 | 13.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1105.18 |
F8 SW APARTMENT | 08-AUG-17:20 | 0.00 | -3370.22 | 0.00 | 0.00 | 140.52 | 87.56 | 588.62 | 2959.03 | 0.00 | 133.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -539.46 |
F8 NW APARTMENT | 28-JUN-18:00 | 0.00 | -2964.25 | 0.00 | 0.00 | 140.95 | 87.56 | 588.62 | 3026.09 | 0.00 | 310.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1189.54 |
F8 SE APARTMENT | 12-SEP-13:30 | 0.00 | -3175.62 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3554.35 | 0.00 | 266.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1081.68 |
F8 NE APARTMENT | 19-JUN-10:30 | 0.00 | -2262.44 | 0.00 | 0.00 | 40.75 | 12.97 | 412.03 | 2189.18 | 0.00 | 244.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -637.37 |
F8 N1 APARTMENT | 16-JUN-19:00 | 0.00 | -1561.22 | 0.00 | 0.00 | 140.47 | 103.77 | 547.42 | 61.17 | 0.00 | 482.24 | 226.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 N2 APARTMENT | 16-JUN-19:00 | 0.00 | -1546.05 | 0.00 | 0.00 | 140.36 | 103.77 | 547.42 | 60.99 | 0.00 | 475.60 | 217.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 S1 APARTMENT | 14-SEP-13:30 | 0.00 | -2418.58 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3075.48 | 0.00 | 12.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1106.21 |
F8 S2 APARTMENT | 14-SEP-13:30 | 0.00 | -2429.22 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3075.29 | 0.00 | 12.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1095.36 |
F9 SW APARTMENT | 08-AUG-17:20 | 0.00 | -3462.63 | 0.00 | 0.00 | 140.70 | 87.56 | 588.62 | 2954.27 | 0.00 | 139.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -448.10 |
F9 NW APARTMENT | 28-JUN-18:00 | 0.00 | -3045.49 | 0.00 | 0.00 | 141.03 | 87.56 | 588.62 | 3019.09 | 0.00 | 318.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1108.85 |
F9 SE APARTMENT | 12-SEP-13:30 | 0.00 | -3235.67 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3548.18 | 0.00 | 274.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1023.43 |
F9 NE APARTMENT | 19-JUN-10:30 | 0.00 | -2295.26 | 0.00 | 0.00 | 40.75 | 12.97 | 412.03 | 2182.73 | 0.00 | 250.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -603.31 |
F9 N1 APARTMENT | 16-JUN-19:00 | 0.00 | -1644.95 | 0.00 | 0.00 | 140.48 | 103.77 | 547.42 | 58.81 | 0.00 | 495.66 | 298.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 N2 APARTMENT | 16-JUN-19:00 | 0.00 | -1629.69 | 0.00 | 0.00 | 140.37 | 103.77 | 547.42 | 58.64 | 0.00 | 488.93 | 290.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 S1 APARTMENT | 14-SEP-13:30 | 0.00 | -2468.19 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3069.17 | 0.00 | 15.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1053.05 |
F9 S2 APARTMENT | 14-SEP-13:30 | 0.00 | -2480.15 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3068.95 | 0.00 | 15.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1040.82 |
T SW APARTMENT | 11-SEP-15:15 | 0.00 | -4257.89 | 0.00 | 0.00 | 48.74 | 45.40 | 470.89 | 4236.79 | 0.00 | 58.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -602.40 |
T NW APARTMENT | 18-JUL-18:30 | 0.00 | -3741.39 | 0.00 | 0.00 | 138.63 | 103.77 | 547.42 | 3088.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -137.17 |
T SE APARTMENT | 12-SEP-13:30 | 0.00 | -3982.11 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 3497.40 | 0.00 | 277.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -228.97 |
T NE APARTMENT | 18-JUL-10:30 | 0.00 | -2938.50 | 0.00 | 0.00 | 40.75 | 12.97 | 412.03 | 1956.79 | 0.00 | 223.60 | 292.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 27-JUN-19:00 | 0.00 | -2226.26 | 0.00 | 0.00 | 141.81 | 103.77 | 547.42 | 928.65 | 0.00 | 476.10 | 28.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 27-JUN-19:00 | 0.00 | -2223.88 | 0.00 | 0.00 | 141.81 | 103.77 | 547.42 | 929.56 | 0.00 | 481.58 | 19.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 12-SEP-13:15 | 0.00 | -3330.98 | 0.00 | 0.00 | 40.55 | 12.97 | 382.60 | 3273.22 | 0.00 | 153.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -531.83 |
T S2 APARTMENT | 12-SEP-13:15 | 0.00 | -3342.13 | 0.00 | 0.00 | 40.54 | 12.97 | 382.60 | 3272.91 | 0.00 | 153.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -520.02 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 30-JUN-15:15 | 0.00 | -179226.67 | 0.00 | 0.00 | 3916.72 | 11666.77 | 38153.89 | 133163.13 | 0.00 | 35875.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -43548.94 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 25-DEC-08:53 | 2399.21 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1154.16 | 0.00 | -1038.60 | -688.37 |
G NW APARTMENT | 25-DEC-08:53 | 2527.03 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1270.43 | 0.00 | -1038.60 | -699.91 |
OFFICE | 25-DEC-09:00 | 2411.27 | 0.00 | 0.00 | 0.00 | 0.00 | 469.18 | 194.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1074.18 | 0.00 | -1038.60 | -961.91 |
G NE APARTMENT | 25-DEC-08:53 | 2500.67 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1186.54 | 0.00 | -1038.61 | -757.42 |
G N1 APARTMENT | 23-FEB-08:30 | 1611.94 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -764.51 | 0.00 | -435.20 | -894.15 |
G N2 APARTMENT | 23-FEB-08:30 | 1598.25 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -764.78 | 0.00 | -435.20 | -880.18 |
G S1 APARTMENT | 25-DEC-08:53 | 1443.80 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -660.27 | 0.00 | -626.46 | -638.99 |
G S2 APARTMENT | 25-DEC-08:53 | 1436.62 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -660.43 | 0.00 | -626.46 | -631.65 |
F2 SW APARTMENT | 25-DEC-08:53 | 2465.10 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1220.67 | 0.00 | -1493.35 | -233.00 |
F2 NW APARTMENT | 25-DEC-08:53 | 2668.69 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1343.14 | 0.00 | -1493.35 | -314.12 |
F2 SE APARTMENT | 25-DEC-08:53 | 2405.46 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1135.00 | 0.00 | -1493.35 | -259.03 |
F2 NE APARTMENT | 25-DEC-08:53 | 2634.29 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1253.75 | 0.00 | -1493.36 | -369.10 |
F2 N1 APARTMENT | 25-DEC-12:00 | 1483.05 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -599.67 | 0.00 | -946.69 | -409.11 |
F2 N2 APARTMENT | 25-DEC-12:00 | 1481.91 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -599.70 | 0.00 | -946.69 | -407.94 |
F2 S1 APARTMENT | 25-DEC-12:00 | 1236.22 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -398.82 | 0.00 | -946.68 | -363.14 |
F2 S2 APARTMENT | 25-DEC-12:00 | 1232.97 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -398.90 | 0.00 | -946.68 | -359.81 |
F3 SW APARTMENT | 25-DEC-08:53 | 2653.51 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1245.85 | 0.00 | -1768.63 | -120.94 |
F3 NW APARTMENT | 25-DEC-12:00 | 2879.21 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1007.64 | 0.00 | -1858.83 | -485.16 |
F3 SE APARTMENT | 25-DEC-08:53 | 2609.47 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1156.75 | 0.00 | -1768.63 | -166.01 |
F3 NE APARTMENT | 25-DEC-12:00 | 2844.72 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -978.34 | 0.00 | -1858.85 | -479.96 |
F3 N1 APARTMENT | 20-APR-11:25 | 1626.64 | 0.00 | 0.00 | 0.00 | 45.41 | 12.97 | 406.15 | 329.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1661.05 | -759.17 |
F3 N2 APARTMENT | 20-APR-11:25 | 1644.32 | 0.00 | 0.00 | 0.00 | 45.43 | 12.97 | 406.15 | 329.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1660.51 | -777.54 |
F3 S1 APARTMENT | 25-DEC-12:00 | 1312.49 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -415.26 | 0.00 | -1121.20 | -248.46 |
F3 S2 APARTMENT | 25-DEC-12:00 | 1310.35 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -415.32 | 0.00 | -1121.20 | -246.25 |
F4 SW APARTMENT | 25-DEC-08:53 | 2847.06 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1261.64 | 0.00 | -1977.53 | -89.81 |
F4 NW APARTMENT | 25-DEC-12:00 | 3093.79 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1027.99 | 0.00 | -2078.40 | -459.81 |
F4 SE APARTMENT | 25-DEC-12:00 | 2805.26 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -793.41 | 0.00 | -2078.40 | -405.87 |
F4 NE APARTMENT | 25-DEC-12:00 | 3057.39 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -996.35 | 0.00 | -2078.42 | -455.04 |
F4 N1 APARTMENT | 20-APR-11:25 | 1927.34 | 0.00 | 0.00 | 0.00 | 45.53 | 12.97 | 406.15 | 323.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1809.45 | -906.40 |
F4 N2 APARTMENT | 20-APR-11:25 | 1931.04 | 0.00 | 0.00 | 0.00 | 45.55 | 12.97 | 406.15 | 323.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1809.13 | -910.56 |
F4 S1 APARTMENT | 25-DEC-12:00 | 1424.68 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -425.25 | 0.00 | -1253.64 | -218.22 |
F4 S2 APARTMENT | 25-DEC-12:00 | 1422.81 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -425.31 | 0.00 | -1253.64 | -216.29 |
M SW APARTMENT | 25-DEC-12:00 | 3010.90 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -838.88 | 0.00 | -2259.52 | -384.93 |
M NW APARTMENT | 25-DEC-12:00 | 3261.00 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1043.72 | 0.00 | -2259.52 | -430.18 |
M SE APARTMENT | 25-DEC-12:00 | 2971.09 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -805.53 | 0.00 | -2259.52 | -378.46 |
M NE APARTMENT | 25-DEC-12:00 | 3223.29 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1010.39 | 0.00 | -2259.54 | -425.79 |
M N1 APARTMENT | 20-APR-11:25 | 2057.82 | 0.00 | 0.00 | 0.00 | 45.60 | 12.97 | 406.15 | 319.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1938.80 | -903.63 |
M N2 APARTMENT | 20-APR-11:25 | 2052.02 | 0.00 | 0.00 | 0.00 | 45.61 | 12.97 | 406.15 | 319.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1938.74 | -897.99 |
M S1 APARTMENT | 25-DEC-12:00 | 1516.06 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -433.03 | 0.00 | -1362.88 | -192.57 |
M S2 APARTMENT | 25-DEC-12:00 | 1514.33 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -433.09 | 0.00 | -1362.88 | -190.79 |
F6 SW APARTMENT | 25-DEC-12:00 | 3206.03 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -848.04 | 0.00 | -2415.70 | -414.71 |
F6 NW APARTMENT | 25-DEC-12:00 | 3457.32 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1054.53 | 0.00 | -2415.70 | -459.52 |
F6 SE APARTMENT | 25-DEC-12:00 | 3165.47 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -813.36 | 0.00 | -2415.70 | -408.84 |
F6 NE APARTMENT | 25-DEC-12:00 | 3418.43 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1019.89 | 0.00 | -2415.72 | -455.24 |
F6 N1 APARTMENT | 20-APR-11:25 | 2066.76 | 0.00 | 0.00 | 0.00 | 45.94 | 12.97 | 406.15 | 320.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2053.82 | -798.00 |
F6 N2 APARTMENT | 20-APR-11:25 | 2062.17 | 0.00 | 0.00 | 0.00 | 45.95 | 12.97 | 406.15 | 320.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2053.77 | -793.51 |
F6 S1 APARTMENT | 25-DEC-12:00 | 1641.94 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -437.89 | 0.00 | -1457.09 | -219.39 |
F6 S2 APARTMENT | 25-DEC-12:00 | 1640.26 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -437.94 | 0.00 | -1457.09 | -217.66 |
F7 SW APARTMENT | 25-DEC-12:00 | 3367.05 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -856.20 | 0.00 | -2554.18 | -429.10 |
F7 NW APARTMENT | 25-DEC-12:00 | 3616.88 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1064.01 | 0.00 | -2554.18 | -471.11 |
F7 SE APARTMENT | 25-DEC-12:00 | 3325.96 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -820.43 | 0.00 | -2554.18 | -423.77 |
F7 NE APARTMENT | 25-DEC-12:00 | 3577.10 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1028.32 | 0.00 | -2554.21 | -467.00 |
F7 N1 APARTMENT | 20-APR-11:25 | 2104.63 | 0.00 | 0.00 | 0.00 | 46.16 | 12.97 | 406.15 | 319.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2158.21 | -731.01 |
F7 N2 APARTMENT | 20-APR-11:25 | 2101.07 | 0.00 | 0.00 | 0.00 | 46.17 | 12.97 | 406.15 | 319.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2158.17 | -727.48 |
F7 S1 APARTMENT | 25-DEC-12:00 | 1744.94 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -442.26 | 0.00 | -1540.61 | -234.49 |
F7 S2 APARTMENT | 25-DEC-12:00 | 1743.30 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -442.31 | 0.00 | -1540.61 | -232.80 |
F8 SW APARTMENT | 25-DEC-12:00 | 3521.89 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -862.94 | 0.00 | -2679.33 | -452.04 |
F8 NW APARTMENT | 25-DEC-12:00 | 3768.26 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1071.92 | 0.00 | -2679.34 | -489.43 |
F8 SE APARTMENT | 25-DEC-12:00 | 3480.04 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -826.29 | 0.00 | -2679.33 | -446.84 |
F8 NE APARTMENT | 25-DEC-12:00 | 3727.76 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1035.35 | 0.00 | -2679.36 | -485.46 |
F8 N1 APARTMENT | 20-APR-11:25 | 2148.09 | 0.00 | 0.00 | 0.00 | 46.33 | 12.97 | 406.15 | 318.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2254.41 | -677.67 |
F8 N2 APARTMENT | 20-APR-11:25 | 2145.09 | 0.00 | 0.00 | 0.00 | 46.34 | 12.97 | 406.15 | 318.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2254.39 | -674.67 |
F8 S1 APARTMENT | 25-DEC-12:00 | 1848.57 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -445.79 | 0.00 | -1616.10 | -259.10 |
F8 S2 APARTMENT | 25-DEC-12:00 | 1846.92 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -445.83 | 0.00 | -1616.10 | -257.40 |
F9 SW APARTMENT | 25-DEC-12:00 | 3783.13 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -864.87 | 0.00 | -2794.04 | -596.64 |
F9 NW APARTMENT | 25-DEC-12:00 | 4016.58 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1075.20 | 0.00 | -2794.05 | -619.75 |
F9 SE APARTMENT | 25-DEC-12:00 | 3739.92 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -827.51 | 0.00 | -2794.04 | -590.79 |
F9 NE APARTMENT | 25-DEC-12:00 | 3974.89 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1037.93 | 0.00 | -2794.07 | -615.31 |
F9 N1 APARTMENT | 25-DEC-12:00 | 2313.90 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -661.12 | 0.00 | -1685.32 | -439.89 |
F9 N2 APARTMENT | 25-DEC-12:00 | 2312.55 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -661.16 | 0.00 | -1685.32 | -438.50 |
F9 S1 APARTMENT | 25-DEC-12:00 | 2055.54 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -446.11 | 0.00 | -1685.29 | -396.56 |
F9 S2 APARTMENT | 25-DEC-12:00 | 2053.76 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -446.15 | 0.00 | -1685.29 | -394.73 |
T SW APARTMENT | 25-DEC-08:53 | 4538.48 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1265.88 | 0.00 | -2759.16 | -995.35 |
T NW APARTMENT | 25-DEC-08:53 | 4667.59 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1403.65 | 0.00 | -2759.16 | -986.70 |
T SE APARTMENT | 25-DEC-08:53 | 4491.55 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1170.18 | 0.00 | -2759.16 | -1044.14 |
T NE APARTMENT | 25-DEC-08:53 | 4622.02 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1305.39 | 0.00 | -2759.17 | -1039.38 |
T N1 APARTMENT | 25-DEC-08:53 | 2953.48 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -857.67 | 0.00 | -1664.33 | -913.40 |
T N2 APARTMENT | 25-DEC-08:53 | 2952.70 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -857.68 | 0.00 | -1664.33 | -912.61 |
T S1 APARTMENT | 25-DEC-08:53 | 2804.50 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -720.49 | 0.00 | -1664.32 | -901.61 |
T S2 APARTMENT | 25-DEC-08:53 | 2803.39 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -720.51 | 0.00 | -1664.32 | -900.48 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F2 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F3 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F4 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F6 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F7 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F8 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
F9 CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 25-DEC-08:53 | 201727.94 | 0.00 | 0.00 | 0.00 | 5843.73 | 7740.61 | 31402.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -84096.17 | 0.00 | -145451.48 | -17166.79 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:13
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:13
Sec1.1A-General InformationData | |
Weather File | Helena Regional Airport MT USA TMY3 WMO#=727720 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 7836.48 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.50 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F2 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F3 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F4 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F6 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F7 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F8 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
F9 S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F2 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F3 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F4 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F6 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F7 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F8 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
F9 CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 7836.48 | 7059.89 | 776.58 |
Data | |
Number of hours heating loads not met | 148.75 |
Number of hours cooling loads not met | 74.25 |
Number of hours not met | 225.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 296.56 | 11327.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 162.57 | 10364.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 235.82 | 64693.70 | 852.88 | 232623.68 | 0.00 | 0.00 |
Space Cooling | 234.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 56.66 | 1814.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 8.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 737.27 | 23378.63 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 0.00 | 0.00 | 1251.16 | 81610.68 | 0.00 | 0.00 |
Receptacle Equipment | 1137.32 | 57042.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 2904.97 | 2104.04 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 1137.32 | 2904.97 |
Natural Gas | 0.00 | 2104.04 |
Additional | 0.00 | 0.00 |
Total | 1137.32 | 5009.02 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 37.84 |
Space Heating | 30.09 |
Space Cooling | 29.88 |
Fans-Interior | 94.08 |
Service Water Heating | 0.00 |
Receptacle Equipment | 145.13 |
Miscellaneous | 33.67 |
Subtotal | 370.70 |
Natural Gas [MJ/m2] | |
Space Heating | 108.84 |
Service Water Heating | 159.66 |
Miscellaneous | -0.00 |
Subtotal | 268.49 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 5.92 |
Space Heating | 21.73 |
Space Cooling | 4.67 |
Fans-Interior | 14.72 |
Service Water Heating | 24.98 |
Receptacle Equipment | 22.71 |
Miscellaneous | 5.27 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:13
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.257918 |
G NW APARTMENT DIRECT AIR | 0.232276 |
OFFICE DIRECT AIR | 0.391958 |
G NE APARTMENT DIRECT AIR | 0.167596 |
G N1 APARTMENT DIRECT AIR | 0.115949 |
G N2 APARTMENT DIRECT AIR | 0.115956 |
G S1 APARTMENT DIRECT AIR | 0.165413 |
G S2 APARTMENT DIRECT AIR | 0.172810 |
F2 SW APARTMENT DIRECT AIR | 0.337846 |
F2 NW APARTMENT DIRECT AIR | 0.301073 |
F2 SE APARTMENT DIRECT AIR | 0.332695 |
F2 NE APARTMENT DIRECT AIR | 0.223056 |
F2 N1 APARTMENT DIRECT AIR | 0.152951 |
F2 N2 APARTMENT DIRECT AIR | 0.151254 |
F2 S1 APARTMENT DIRECT AIR | 0.221835 |
F2 S2 APARTMENT DIRECT AIR | 0.224574 |
F3 SW APARTMENT DIRECT AIR | 0.340896 |
F3 NW APARTMENT DIRECT AIR | 0.305105 |
F3 SE APARTMENT DIRECT AIR | 0.314353 |
F3 NE APARTMENT DIRECT AIR | 0.228348 |
F3 N1 APARTMENT DIRECT AIR | 0.157816 |
F3 N2 APARTMENT DIRECT AIR | 0.156126 |
F3 S1 APARTMENT DIRECT AIR | 0.227765 |
F3 S2 APARTMENT DIRECT AIR | 0.229046 |
F4 SW APARTMENT DIRECT AIR | 0.343027 |
F4 NW APARTMENT DIRECT AIR | 0.307095 |
F4 SE APARTMENT DIRECT AIR | 0.315321 |
F4 NE APARTMENT DIRECT AIR | 0.230249 |
F4 N1 APARTMENT DIRECT AIR | 0.159738 |
F4 N2 APARTMENT DIRECT AIR | 0.158055 |
F4 S1 APARTMENT DIRECT AIR | 0.230361 |
F4 S2 APARTMENT DIRECT AIR | 0.231433 |
M SW APARTMENT DIRECT AIR | 0.347132 |
M NW APARTMENT DIRECT AIR | 0.310910 |
M SE APARTMENT DIRECT AIR | 0.319896 |
M NE APARTMENT DIRECT AIR | 0.234052 |
M N1 APARTMENT DIRECT AIR | 0.163300 |
M N2 APARTMENT DIRECT AIR | 0.161623 |
M S1 APARTMENT DIRECT AIR | 0.234505 |
M S2 APARTMENT DIRECT AIR | 0.235548 |
F6 SW APARTMENT DIRECT AIR | 0.344778 |
F6 NW APARTMENT DIRECT AIR | 0.308015 |
F6 SE APARTMENT DIRECT AIR | 0.318048 |
F6 NE APARTMENT DIRECT AIR | 0.231318 |
F6 N1 APARTMENT DIRECT AIR | 0.160521 |
F6 N2 APARTMENT DIRECT AIR | 0.158858 |
F6 S1 APARTMENT DIRECT AIR | 0.232111 |
F6 S2 APARTMENT DIRECT AIR | 0.233151 |
F7 SW APARTMENT DIRECT AIR | 0.344630 |
F7 NW APARTMENT DIRECT AIR | 0.307475 |
F7 SE APARTMENT DIRECT AIR | 0.318340 |
F7 NE APARTMENT DIRECT AIR | 0.230851 |
F7 N1 APARTMENT DIRECT AIR | 0.159953 |
F7 N2 APARTMENT DIRECT AIR | 0.158300 |
F7 S1 APARTMENT DIRECT AIR | 0.231882 |
F7 S2 APARTMENT DIRECT AIR | 0.232921 |
F8 SW APARTMENT DIRECT AIR | 0.345641 |
F8 NW APARTMENT DIRECT AIR | 0.308290 |
F8 SE APARTMENT DIRECT AIR | 0.319701 |
F8 NE APARTMENT DIRECT AIR | 0.231531 |
F8 N1 APARTMENT DIRECT AIR | 0.160663 |
F8 N2 APARTMENT DIRECT AIR | 0.159021 |
F8 S1 APARTMENT DIRECT AIR | 0.232797 |
F8 S2 APARTMENT DIRECT AIR | 0.233839 |
F9 SW APARTMENT DIRECT AIR | 0.355198 |
F9 NW APARTMENT DIRECT AIR | 0.318178 |
F9 SE APARTMENT DIRECT AIR | 0.327431 |
F9 NE APARTMENT DIRECT AIR | 0.234918 |
F9 N1 APARTMENT DIRECT AIR | 0.169223 |
F9 N2 APARTMENT DIRECT AIR | 0.167569 |
F9 S1 APARTMENT DIRECT AIR | 0.239058 |
F9 S2 APARTMENT DIRECT AIR | 0.240230 |
T SW APARTMENT DIRECT AIR | 0.439596 |
T NW APARTMENT DIRECT AIR | 0.384478 |
T SE APARTMENT DIRECT AIR | 0.402413 |
T NE APARTMENT DIRECT AIR | 0.294749 |
T N1 APARTMENT DIRECT AIR | 0.222082 |
T N2 APARTMENT DIRECT AIR | 0.221823 |
T S1 APARTMENT DIRECT AIR | 0.325921 |
T S2 APARTMENT DIRECT AIR | 0.327061 |
Maximum Flow Rate [m3/s] | |
AIRLOOP G SW MAIN BRANCH | 0.257918 |
AIRLOOP G NW MAIN BRANCH | 0.232276 |
AIRLOOP OFFICE MAIN BRANCH | 0.391958 |
AIRLOOP G NE MAIN BRANCH | 0.167596 |
AIRLOOP G N1 MAIN BRANCH | 0.115949 |
AIRLOOP G N2 MAIN BRANCH | 0.115956 |
AIRLOOP G S1 MAIN BRANCH | 0.165413 |
AIRLOOP G S2 MAIN BRANCH | 0.172810 |
AIRLOOP F2 SW MAIN BRANCH | 0.337846 |
AIRLOOP F2 NW MAIN BRANCH | 0.301073 |
AIRLOOP F2 SE MAIN BRANCH | 0.332695 |
AIRLOOP F2 NE MAIN BRANCH | 0.223056 |
AIRLOOP F2 N1 MAIN BRANCH | 0.152951 |
AIRLOOP F2 N2 MAIN BRANCH | 0.151254 |
AIRLOOP F2 S1 MAIN BRANCH | 0.221835 |
AIRLOOP F2 S2 MAIN BRANCH | 0.224574 |
AIRLOOP F3 SW MAIN BRANCH | 0.340896 |
AIRLOOP F3 NW MAIN BRANCH | 0.305105 |
AIRLOOP F3 SE MAIN BRANCH | 0.314353 |
AIRLOOP F3 NE MAIN BRANCH | 0.228348 |
AIRLOOP F3 N1 MAIN BRANCH | 0.157816 |
AIRLOOP F3 N2 MAIN BRANCH | 0.156126 |
AIRLOOP F3 S1 MAIN BRANCH | 0.227765 |
AIRLOOP F3 S2 MAIN BRANCH | 0.229046 |
AIRLOOP F4 SW MAIN BRANCH | 0.343027 |
AIRLOOP F4 NW MAIN BRANCH | 0.307095 |
AIRLOOP F4 SE MAIN BRANCH | 0.315321 |
AIRLOOP F4 NE MAIN BRANCH | 0.230249 |
AIRLOOP F4 N1 MAIN BRANCH | 0.159738 |
AIRLOOP F4 N2 MAIN BRANCH | 0.158055 |
AIRLOOP F4 S1 MAIN BRANCH | 0.230361 |
AIRLOOP F4 S2 MAIN BRANCH | 0.231433 |
AIRLOOP M SW MAIN BRANCH | 0.347132 |
AIRLOOP M NW MAIN BRANCH | 0.310910 |
AIRLOOP M SE MAIN BRANCH | 0.319896 |
AIRLOOP M NE MAIN BRANCH | 0.234052 |
AIRLOOP M N1 MAIN BRANCH | 0.163300 |
AIRLOOP M N2 MAIN BRANCH | 0.161623 |
AIRLOOP M S1 MAIN BRANCH | 0.234505 |
AIRLOOP M S2 MAIN BRANCH | 0.235548 |
AIRLOOP F6 SW MAIN BRANCH | 0.344778 |
AIRLOOP F6 NW MAIN BRANCH | 0.308015 |
AIRLOOP F6 SE MAIN BRANCH | 0.318048 |
AIRLOOP F6 NE MAIN BRANCH | 0.231318 |
AIRLOOP F6 N1 MAIN BRANCH | 0.160521 |
AIRLOOP F6 N2 MAIN BRANCH | 0.158858 |
AIRLOOP F6 S1 MAIN BRANCH | 0.232111 |
AIRLOOP F6 S2 MAIN BRANCH | 0.233151 |
AIRLOOP F7 SW MAIN BRANCH | 0.344630 |
AIRLOOP F7 NW MAIN BRANCH | 0.307475 |
AIRLOOP F7 SE MAIN BRANCH | 0.318340 |
AIRLOOP F7 NE MAIN BRANCH | 0.230851 |
AIRLOOP F7 N1 MAIN BRANCH | 0.159953 |
AIRLOOP F7 N2 MAIN BRANCH | 0.158300 |
AIRLOOP F7 S1 MAIN BRANCH | 0.231882 |
AIRLOOP F7 S2 MAIN BRANCH | 0.232921 |
AIRLOOP F8 SW MAIN BRANCH | 0.345641 |
AIRLOOP F8 NW MAIN BRANCH | 0.308290 |
AIRLOOP F8 SE MAIN BRANCH | 0.319701 |
AIRLOOP F8 NE MAIN BRANCH | 0.231531 |
AIRLOOP F8 N1 MAIN BRANCH | 0.160663 |
AIRLOOP F8 N2 MAIN BRANCH | 0.159021 |
AIRLOOP F8 S1 MAIN BRANCH | 0.232797 |
AIRLOOP F8 S2 MAIN BRANCH | 0.233839 |
AIRLOOP F9 SW MAIN BRANCH | 0.355198 |
AIRLOOP F9 NW MAIN BRANCH | 0.318178 |
AIRLOOP F9 SE MAIN BRANCH | 0.327431 |
AIRLOOP F9 NE MAIN BRANCH | 0.234918 |
AIRLOOP F9 N1 MAIN BRANCH | 0.169223 |
AIRLOOP F9 N2 MAIN BRANCH | 0.167569 |
AIRLOOP F9 S1 MAIN BRANCH | 0.239058 |
AIRLOOP F9 S2 MAIN BRANCH | 0.240230 |
AIRLOOP T SW MAIN BRANCH | 0.439596 |
AIRLOOP T NW MAIN BRANCH | 0.384478 |
AIRLOOP T SE MAIN BRANCH | 0.402413 |
AIRLOOP T NE MAIN BRANCH | 0.294749 |
AIRLOOP T N1 MAIN BRANCH | 0.222082 |
AIRLOOP T N2 MAIN BRANCH | 0.221823 |
AIRLOOP T S1 MAIN BRANCH | 0.325921 |
AIRLOOP T S2 MAIN BRANCH | 0.327061 |
Design Supply Air Flow Rate [m3/s] | |
AIRLOOP G SW | 0.257918 |
AIRLOOP G NW | 0.232276 |
AIRLOOP OFFICE | 0.391958 |
AIRLOOP G NE | 0.167596 |
AIRLOOP G N1 | 0.115949 |
AIRLOOP G N2 | 0.115956 |
AIRLOOP G S1 | 0.165413 |
AIRLOOP G S2 | 0.172810 |
AIRLOOP F2 SW | 0.337846 |
AIRLOOP F2 NW | 0.301073 |
AIRLOOP F2 SE | 0.332695 |
AIRLOOP F2 NE | 0.223056 |
AIRLOOP F2 N1 | 0.152951 |
AIRLOOP F2 N2 | 0.151254 |
AIRLOOP F2 S1 | 0.221835 |
AIRLOOP F2 S2 | 0.224574 |
AIRLOOP F3 SW | 0.340896 |
AIRLOOP F3 NW | 0.305105 |
AIRLOOP F3 SE | 0.314353 |
AIRLOOP F3 NE | 0.228348 |
AIRLOOP F3 N1 | 0.157816 |
AIRLOOP F3 N2 | 0.156126 |
AIRLOOP F3 S1 | 0.227765 |
AIRLOOP F3 S2 | 0.229046 |
AIRLOOP F4 SW | 0.343027 |
AIRLOOP F4 NW | 0.307095 |
AIRLOOP F4 SE | 0.315321 |
AIRLOOP F4 NE | 0.230249 |
AIRLOOP F4 N1 | 0.159738 |
AIRLOOP F4 N2 | 0.158055 |
AIRLOOP F4 S1 | 0.230361 |
AIRLOOP F4 S2 | 0.231433 |
AIRLOOP M SW | 0.347132 |
AIRLOOP M NW | 0.310910 |
AIRLOOP M SE | 0.319896 |
AIRLOOP M NE | 0.234052 |
AIRLOOP M N1 | 0.163300 |
AIRLOOP M N2 | 0.161623 |
AIRLOOP M S1 | 0.234505 |
AIRLOOP M S2 | 0.235548 |
AIRLOOP F6 SW | 0.344778 |
AIRLOOP F6 NW | 0.308015 |
AIRLOOP F6 SE | 0.318048 |
AIRLOOP F6 NE | 0.231318 |
AIRLOOP F6 N1 | 0.160521 |
AIRLOOP F6 N2 | 0.158858 |
AIRLOOP F6 S1 | 0.232111 |
AIRLOOP F6 S2 | 0.233151 |
AIRLOOP F7 SW | 0.344630 |
AIRLOOP F7 NW | 0.307475 |
AIRLOOP F7 SE | 0.318340 |
AIRLOOP F7 NE | 0.230851 |
AIRLOOP F7 N1 | 0.159953 |
AIRLOOP F7 N2 | 0.158300 |
AIRLOOP F7 S1 | 0.231882 |
AIRLOOP F7 S2 | 0.232921 |
AIRLOOP F8 SW | 0.345641 |
AIRLOOP F8 NW | 0.308290 |
AIRLOOP F8 SE | 0.319701 |
AIRLOOP F8 NE | 0.231531 |
AIRLOOP F8 N1 | 0.160663 |
AIRLOOP F8 N2 | 0.159021 |
AIRLOOP F8 S1 | 0.232797 |
AIRLOOP F8 S2 | 0.233839 |
AIRLOOP F9 SW | 0.355198 |
AIRLOOP F9 NW | 0.318178 |
AIRLOOP F9 SE | 0.327431 |
AIRLOOP F9 NE | 0.234918 |
AIRLOOP F9 N1 | 0.169223 |
AIRLOOP F9 N2 | 0.167569 |
AIRLOOP F9 S1 | 0.239058 |
AIRLOOP F9 S2 | 0.240230 |
AIRLOOP T SW | 0.439596 |
AIRLOOP T NW | 0.384478 |
AIRLOOP T SE | 0.402413 |
AIRLOOP T NE | 0.294749 |
AIRLOOP T N1 | 0.222082 |
AIRLOOP T N2 | 0.221823 |
AIRLOOP T S1 | 0.325921 |
AIRLOOP T S2 | 0.327061 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
AIRLOOP G SW OA CONTROLLER | 0.257918 | 0.025952 |
AIRLOOP G NW OA CONTROLLER | 0.232276 | 0.025952 |
AIRLOOP OFFICE OA CONTROLLER | 0.391958 | 0.038103 |
AIRLOOP G NE OA CONTROLLER | 0.167596 | 0.025952 |
AIRLOOP G N1 OA CONTROLLER | 0.115949 | 0.025952 |
AIRLOOP G N2 OA CONTROLLER | 0.115956 | 0.025952 |
AIRLOOP G S1 OA CONTROLLER | 0.165413 | 0.025952 |
AIRLOOP G S2 OA CONTROLLER | 0.172810 | 0.025952 |
AIRLOOP F2 SW OA CONTROLLER | 0.337846 | 0.025952 |
AIRLOOP F2 NW OA CONTROLLER | 0.301073 | 0.025952 |
AIRLOOP F2 SE OA CONTROLLER | 0.332695 | 0.025952 |
AIRLOOP F2 NE OA CONTROLLER | 0.223056 | 0.025952 |
AIRLOOP F2 N1 OA CONTROLLER | 0.152951 | 0.025952 |
AIRLOOP F2 N2 OA CONTROLLER | 0.151254 | 0.025952 |
AIRLOOP F2 S1 OA CONTROLLER | 0.221835 | 0.025952 |
AIRLOOP F2 S2 OA CONTROLLER | 0.224574 | 0.025952 |
AIRLOOP F3 SW OA CONTROLLER | 0.340896 | 0.025952 |
AIRLOOP F3 NW OA CONTROLLER | 0.305105 | 0.025952 |
AIRLOOP F3 SE OA CONTROLLER | 0.314353 | 0.025952 |
AIRLOOP F3 NE OA CONTROLLER | 0.228348 | 0.025952 |
AIRLOOP F3 N1 OA CONTROLLER | 0.157816 | 0.025952 |
AIRLOOP F3 N2 OA CONTROLLER | 0.156126 | 0.025952 |
AIRLOOP F3 S1 OA CONTROLLER | 0.227765 | 0.025952 |
AIRLOOP F3 S2 OA CONTROLLER | 0.229046 | 0.025952 |
AIRLOOP F4 SW OA CONTROLLER | 0.343027 | 0.025952 |
AIRLOOP F4 NW OA CONTROLLER | 0.307095 | 0.025952 |
AIRLOOP F4 SE OA CONTROLLER | 0.315321 | 0.025952 |
AIRLOOP F4 NE OA CONTROLLER | 0.230249 | 0.025952 |
AIRLOOP F4 N1 OA CONTROLLER | 0.159738 | 0.025952 |
AIRLOOP F4 N2 OA CONTROLLER | 0.158055 | 0.025952 |
AIRLOOP F4 S1 OA CONTROLLER | 0.230361 | 0.025952 |
AIRLOOP F4 S2 OA CONTROLLER | 0.231433 | 0.025952 |
AIRLOOP M SW OA CONTROLLER | 0.347132 | 0.025952 |
AIRLOOP M NW OA CONTROLLER | 0.310910 | 0.025952 |
AIRLOOP M SE OA CONTROLLER | 0.319896 | 0.025952 |
AIRLOOP M NE OA CONTROLLER | 0.234052 | 0.025952 |
AIRLOOP M N1 OA CONTROLLER | 0.163300 | 0.025952 |
AIRLOOP M N2 OA CONTROLLER | 0.161623 | 0.025952 |
AIRLOOP M S1 OA CONTROLLER | 0.234505 | 0.025952 |
AIRLOOP M S2 OA CONTROLLER | 0.235548 | 0.025952 |
AIRLOOP F6 SW OA CONTROLLER | 0.344778 | 0.025952 |
AIRLOOP F6 NW OA CONTROLLER | 0.308015 | 0.025952 |
AIRLOOP F6 SE OA CONTROLLER | 0.318048 | 0.025952 |
AIRLOOP F6 NE OA CONTROLLER | 0.231318 | 0.025952 |
AIRLOOP F6 N1 OA CONTROLLER | 0.160521 | 0.025952 |
AIRLOOP F6 N2 OA CONTROLLER | 0.158858 | 0.025952 |
AIRLOOP F6 S1 OA CONTROLLER | 0.232111 | 0.025952 |
AIRLOOP F6 S2 OA CONTROLLER | 0.233151 | 0.025952 |
AIRLOOP F7 SW OA CONTROLLER | 0.344630 | 0.025952 |
AIRLOOP F7 NW OA CONTROLLER | 0.307475 | 0.025952 |
AIRLOOP F7 SE OA CONTROLLER | 0.318340 | 0.025952 |
AIRLOOP F7 NE OA CONTROLLER | 0.230851 | 0.025952 |
AIRLOOP F7 N1 OA CONTROLLER | 0.159953 | 0.025952 |
AIRLOOP F7 N2 OA CONTROLLER | 0.158300 | 0.025952 |
AIRLOOP F7 S1 OA CONTROLLER | 0.231882 | 0.025952 |
AIRLOOP F7 S2 OA CONTROLLER | 0.232921 | 0.025952 |
AIRLOOP F8 SW OA CONTROLLER | 0.345641 | 0.025952 |
AIRLOOP F8 NW OA CONTROLLER | 0.308290 | 0.025952 |
AIRLOOP F8 SE OA CONTROLLER | 0.319701 | 0.025952 |
AIRLOOP F8 NE OA CONTROLLER | 0.231531 | 0.025952 |
AIRLOOP F8 N1 OA CONTROLLER | 0.160663 | 0.025952 |
AIRLOOP F8 N2 OA CONTROLLER | 0.159021 | 0.025952 |
AIRLOOP F8 S1 OA CONTROLLER | 0.232797 | 0.025952 |
AIRLOOP F8 S2 OA CONTROLLER | 0.233839 | 0.025952 |
AIRLOOP F9 SW OA CONTROLLER | 0.355198 | 0.025952 |
AIRLOOP F9 NW OA CONTROLLER | 0.318178 | 0.025952 |
AIRLOOP F9 SE OA CONTROLLER | 0.327431 | 0.025952 |
AIRLOOP F9 NE OA CONTROLLER | 0.234918 | 0.025952 |
AIRLOOP F9 N1 OA CONTROLLER | 0.169223 | 0.025952 |
AIRLOOP F9 N2 OA CONTROLLER | 0.167569 | 0.025952 |
AIRLOOP F9 S1 OA CONTROLLER | 0.239058 | 0.025952 |
AIRLOOP F9 S2 OA CONTROLLER | 0.240230 | 0.025952 |
AIRLOOP T SW OA CONTROLLER | 0.439596 | 0.025952 |
AIRLOOP T NW OA CONTROLLER | 0.384478 | 0.025952 |
AIRLOOP T SE OA CONTROLLER | 0.402413 | 0.025952 |
AIRLOOP T NE OA CONTROLLER | 0.294749 | 0.025952 |
AIRLOOP T N1 OA CONTROLLER | 0.222082 | 0.025952 |
AIRLOOP T N2 OA CONTROLLER | 0.221823 | 0.025952 |
AIRLOOP T S1 OA CONTROLLER | 0.325921 | 0.025952 |
AIRLOOP T S2 OA CONTROLLER | 0.327061 | 0.025952 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity [W] | Rated Sensible Cooling Capacity [W] | Rated Water Flow Rate [m3/s] | |
HEAT PUMP COOLING MODE AIRLOOP G SW | 0.257918 | 3320.88 | 2262.96 | 0.000073 |
HEAT PUMP COOLING MODE AIRLOOP G NW | 0.232276 | 2936.09 | 2014.22 | 0.000064 |
HEAT PUMP COOLING MODE AIRLOOP OFFICE | 0.391958 | 5108.72 | 3463.07 | 0.000112 |
HEAT PUMP COOLING MODE AIRLOOP G NE | 0.167596 | 2103.58 | 1461.41 | 0.000046 |
HEAT PUMP COOLING MODE AIRLOOP G N1 | 0.115949 | 1439.44 | 1005.49 | 0.000031 |
HEAT PUMP COOLING MODE AIRLOOP G N2 | 0.115956 | 1438.70 | 1005.78 | 0.000031 |
HEAT PUMP COOLING MODE AIRLOOP G S1 | 0.165413 | 2215.71 | 1493.70 | 0.000048 |
HEAT PUMP COOLING MODE AIRLOOP G S2 | 0.172810 | 2309.38 | 1557.11 | 0.000050 |
HEAT PUMP COOLING MODE AIRLOOP F2 SW | 0.337846 | 4269.83 | 2921.78 | 0.000093 |
HEAT PUMP COOLING MODE AIRLOOP F2 NW | 0.301073 | 3781.51 | 2596.83 | 0.000083 |
HEAT PUMP COOLING MODE AIRLOOP F2 SE | 0.332695 | 4282.48 | 2914.93 | 0.000094 |
HEAT PUMP COOLING MODE AIRLOOP F2 NE | 0.223056 | 2777.62 | 1928.66 | 0.000061 |
HEAT PUMP COOLING MODE AIRLOOP F2 N1 | 0.152951 | 1899.41 | 1318.87 | 0.000041 |
HEAT PUMP COOLING MODE AIRLOOP F2 N2 | 0.151254 | 1877.81 | 1304.36 | 0.000041 |
HEAT PUMP COOLING MODE AIRLOOP F2 S1 | 0.221835 | 2914.54 | 1973.91 | 0.000064 |
HEAT PUMP COOLING MODE AIRLOOP F2 S2 | 0.224574 | 2949.27 | 1997.36 | 0.000064 |
HEAT PUMP COOLING MODE AIRLOOP F3 SW | 0.340896 | 4299.74 | 2948.82 | 0.000094 |
HEAT PUMP COOLING MODE AIRLOOP F3 NW | 0.305105 | 3815.75 | 2628.07 | 0.000083 |
HEAT PUMP COOLING MODE AIRLOOP F3 SE | 0.314353 | 4033.67 | 2755.04 | 0.000088 |
HEAT PUMP COOLING MODE AIRLOOP F3 NE | 0.228348 | 2828.81 | 1970.89 | 0.000062 |
HEAT PUMP COOLING MODE AIRLOOP F3 N1 | 0.157816 | 1952.00 | 1358.72 | 0.000043 |
HEAT PUMP COOLING MODE AIRLOOP F3 N2 | 0.156126 | 1930.53 | 1344.28 | 0.000042 |
HEAT PUMP COOLING MODE AIRLOOP F3 S1 | 0.227765 | 2979.77 | 2022.77 | 0.000065 |
HEAT PUMP COOLING MODE AIRLOOP F3 S2 | 0.229046 | 2996.02 | 2033.74 | 0.000065 |
HEAT PUMP COOLING MODE AIRLOOP F4 SW | 0.343027 | 4314.11 | 2964.63 | 0.000094 |
HEAT PUMP COOLING MODE AIRLOOP F4 NW | 0.307095 | 3828.44 | 2642.70 | 0.000084 |
HEAT PUMP COOLING MODE AIRLOOP F4 SE | 0.315321 | 4033.64 | 2760.98 | 0.000088 |
HEAT PUMP COOLING MODE AIRLOOP F4 NE | 0.230249 | 2858.20 | 1992.04 | 0.000062 |
HEAT PUMP COOLING MODE AIRLOOP F4 N1 | 0.159738 | 1969.49 | 1373.86 | 0.000043 |
HEAT PUMP COOLING MODE AIRLOOP F4 N2 | 0.158055 | 1948.14 | 1359.48 | 0.000043 |
HEAT PUMP COOLING MODE AIRLOOP F4 S1 | 0.230361 | 3005.23 | 2043.56 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP F4 S2 | 0.231433 | 3018.83 | 2052.75 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP M SW | 0.347132 | 4383.03 | 3012.36 | 0.000096 |
HEAT PUMP COOLING MODE AIRLOOP M NW | 0.310910 | 3866.61 | 2673.36 | 0.000084 |
HEAT PUMP COOLING MODE AIRLOOP M SE | 0.319896 | 4081.51 | 2798.17 | 0.000089 |
HEAT PUMP COOLING MODE AIRLOOP M NE | 0.234052 | 2896.83 | 2022.74 | 0.000063 |
HEAT PUMP COOLING MODE AIRLOOP M N1 | 0.163300 | 2009.16 | 1403.25 | 0.000044 |
HEAT PUMP COOLING MODE AIRLOOP M N2 | 0.161623 | 1987.90 | 1388.93 | 0.000043 |
HEAT PUMP COOLING MODE AIRLOOP M S1 | 0.234505 | 3051.65 | 2077.87 | 0.000067 |
HEAT PUMP COOLING MODE AIRLOOP M S2 | 0.235548 | 3064.86 | 2086.79 | 0.000067 |
HEAT PUMP COOLING MODE AIRLOOP F6 SW | 0.344778 | 4344.62 | 2990.62 | 0.000095 |
HEAT PUMP COOLING MODE AIRLOOP F6 NW | 0.308015 | 3821.36 | 2647.03 | 0.000083 |
HEAT PUMP COOLING MODE AIRLOOP F6 SE | 0.318048 | 4049.74 | 2780.79 | 0.000088 |
HEAT PUMP COOLING MODE AIRLOOP F6 NE | 0.231318 | 2854.67 | 1997.99 | 0.000062 |
HEAT PUMP COOLING MODE AIRLOOP F6 N1 | 0.160521 | 1969.05 | 1378.61 | 0.000043 |
HEAT PUMP COOLING MODE AIRLOOP F6 N2 | 0.158858 | 1948.00 | 1364.41 | 0.000043 |
HEAT PUMP COOLING MODE AIRLOOP F6 S1 | 0.232111 | 3016.26 | 2056.42 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP F6 S2 | 0.233151 | 3029.43 | 2065.32 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP F7 SW | 0.344630 | 4335.21 | 2987.94 | 0.000095 |
HEAT PUMP COOLING MODE AIRLOOP F7 NW | 0.307475 | 3818.90 | 2647.25 | 0.000083 |
HEAT PUMP COOLING MODE AIRLOOP F7 SE | 0.318340 | 4046.06 | 2781.89 | 0.000088 |
HEAT PUMP COOLING MODE AIRLOOP F7 NE | 0.230851 | 2842.05 | 1992.75 | 0.000062 |
HEAT PUMP COOLING MODE AIRLOOP F7 N1 | 0.159953 | 1957.70 | 1372.98 | 0.000043 |
HEAT PUMP COOLING MODE AIRLOOP F7 N2 | 0.158300 | 1936.80 | 1358.87 | 0.000042 |
HEAT PUMP COOLING MODE AIRLOOP F7 S1 | 0.231882 | 3008.89 | 2053.62 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP F7 S2 | 0.232921 | 3022.05 | 2062.50 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP F8 SW | 0.345641 | 4341.23 | 2995.30 | 0.000095 |
HEAT PUMP COOLING MODE AIRLOOP F8 NW | 0.308290 | 3822.55 | 2652.96 | 0.000084 |
HEAT PUMP COOLING MODE AIRLOOP F8 SE | 0.319701 | 4056.66 | 2792.27 | 0.000089 |
HEAT PUMP COOLING MODE AIRLOOP F8 NE | 0.231531 | 2844.57 | 1997.42 | 0.000062 |
HEAT PUMP COOLING MODE AIRLOOP F8 N1 | 0.160663 | 1963.02 | 1378.36 | 0.000043 |
HEAT PUMP COOLING MODE AIRLOOP F8 N2 | 0.159021 | 1942.29 | 1364.36 | 0.000042 |
HEAT PUMP COOLING MODE AIRLOOP F8 S1 | 0.232797 | 3016.46 | 2060.68 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP F8 S2 | 0.233839 | 3029.64 | 2069.59 | 0.000066 |
HEAT PUMP COOLING MODE AIRLOOP F9 SW | 0.355198 | 4455.68 | 3075.68 | 0.000097 |
HEAT PUMP COOLING MODE AIRLOOP F9 NW | 0.318178 | 3929.50 | 2729.94 | 0.000086 |
HEAT PUMP COOLING MODE AIRLOOP F9 SE | 0.327431 | 4148.48 | 2857.18 | 0.000091 |
HEAT PUMP COOLING MODE AIRLOOP F9 NE | 0.234918 | 2881.51 | 2025.24 | 0.000063 |
HEAT PUMP COOLING MODE AIRLOOP F9 N1 | 0.169223 | 2068.13 | 1450.83 | 0.000045 |
HEAT PUMP COOLING MODE AIRLOOP F9 N2 | 0.167569 | 2047.26 | 1436.72 | 0.000045 |
HEAT PUMP COOLING MODE AIRLOOP F9 S1 | 0.239058 | 3091.81 | 2113.49 | 0.000068 |
HEAT PUMP COOLING MODE AIRLOOP F9 S2 | 0.240230 | 3106.64 | 2123.51 | 0.000068 |
HEAT PUMP COOLING MODE AIRLOOP T SW | 0.439596 | 5539.38 | 3805.10 | 0.000121 |
HEAT PUMP COOLING MODE AIRLOOP T NW | 0.384478 | 4796.19 | 3313.16 | 0.000105 |
HEAT PUMP COOLING MODE AIRLOOP T SE | 0.402413 | 5089.00 | 3496.10 | 0.000111 |
HEAT PUMP COOLING MODE AIRLOOP T NE | 0.294749 | 3731.28 | 2577.25 | 0.000082 |
HEAT PUMP COOLING MODE AIRLOOP T N1 | 0.222082 | 2867.91 | 1965.11 | 0.000063 |
HEAT PUMP COOLING MODE AIRLOOP T N2 | 0.221823 | 2871.19 | 1965.59 | 0.000063 |
HEAT PUMP COOLING MODE AIRLOOP T S1 | 0.325921 | 4186.84 | 2855.17 | 0.000091 |
HEAT PUMP COOLING MODE AIRLOOP T S2 | 0.327061 | 4201.01 | 2864.86 | 0.000092 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Supplemental Heating Coil Nominal Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
AIRLOOP G SW DXAC HEAT PUMP | 0.257918 | 0.257918 | 0.257918 | 0.257918 | 3320.88 | 3320.88 | 4530.04 | 1.00 |
AIRLOOP G NW DXAC HEAT PUMP | 0.232276 | 0.232276 | 0.232276 | 0.232276 | 2936.09 | 2936.09 | 4530.57 | 1.00 |
AIRLOOP OFFICE DXAC HEAT PUMP | 0.391958 | 0.391958 | 0.391958 | 0.391958 | 5108.72 | 5108.72 | 5570.62 | 1.00 |
AIRLOOP G NE DXAC HEAT PUMP | 0.167596 | 0.167596 | 0.167596 | 0.167596 | 2103.58 | 2103.58 | 4536.36 | 1.00 |
AIRLOOP G N1 DXAC HEAT PUMP | 0.115949 | 0.115949 | 0.115949 | 0.115949 | 1439.44 | 1439.44 | 3542.17 | 1.00 |
AIRLOOP G N2 DXAC HEAT PUMP | 0.115956 | 0.115956 | 0.115956 | 0.115956 | 1438.70 | 1438.70 | 3542.30 | 1.00 |
AIRLOOP G S1 DXAC HEAT PUMP | 0.165413 | 0.165413 | 0.165413 | 0.165413 | 2215.71 | 2215.71 | 3539.28 | 1.00 |
AIRLOOP G S2 DXAC HEAT PUMP | 0.172810 | 0.172810 | 0.172810 | 0.172810 | 2309.38 | 2309.38 | 3545.68 | 1.00 |
AIRLOOP F2 SW DXAC HEAT PUMP | 0.337846 | 0.337846 | 0.337846 | 0.337846 | 4269.83 | 4269.83 | 4219.43 | 1.00 |
AIRLOOP F2 NW DXAC HEAT PUMP | 0.301073 | 0.301073 | 0.301073 | 0.301073 | 3781.51 | 3781.51 | 4207.11 | 1.00 |
AIRLOOP F2 SE DXAC HEAT PUMP | 0.332695 | 0.332695 | 0.332695 | 0.332695 | 4282.48 | 4282.48 | 4244.62 | 1.00 |
AIRLOOP F2 NE DXAC HEAT PUMP | 0.223056 | 0.223056 | 0.223056 | 0.223056 | 2777.62 | 2777.62 | 4214.24 | 1.00 |
AIRLOOP F2 N1 DXAC HEAT PUMP | 0.152951 | 0.152951 | 0.152951 | 0.152951 | 1899.41 | 1899.41 | 3017.74 | 1.00 |
AIRLOOP F2 N2 DXAC HEAT PUMP | 0.151254 | 0.151254 | 0.151254 | 0.151254 | 1877.81 | 1877.81 | 3017.90 | 1.00 |
AIRLOOP F2 S1 DXAC HEAT PUMP | 0.221835 | 0.221835 | 0.221835 | 0.221835 | 2914.54 | 2914.54 | 3033.24 | 1.00 |
AIRLOOP F2 S2 DXAC HEAT PUMP | 0.224574 | 0.224574 | 0.224574 | 0.224574 | 2949.27 | 2949.27 | 3034.50 | 1.00 |
AIRLOOP F3 SW DXAC HEAT PUMP | 0.340896 | 0.340896 | 0.340896 | 0.340896 | 4299.74 | 4299.74 | 4172.14 | 1.00 |
AIRLOOP F3 NW DXAC HEAT PUMP | 0.305105 | 0.305105 | 0.305105 | 0.305105 | 3815.75 | 3815.75 | 4162.51 | 1.00 |
AIRLOOP F3 SE DXAC HEAT PUMP | 0.314353 | 0.314353 | 0.314353 | 0.314353 | 4033.67 | 4033.67 | 4180.94 | 1.00 |
AIRLOOP F3 NE DXAC HEAT PUMP | 0.228348 | 0.228348 | 0.228348 | 0.228348 | 2828.81 | 2828.81 | 4169.50 | 1.00 |
AIRLOOP F3 N1 DXAC HEAT PUMP | 0.157816 | 0.157816 | 0.157816 | 0.157816 | 1952.00 | 1952.00 | 2934.43 | 1.00 |
AIRLOOP F3 N2 DXAC HEAT PUMP | 0.156126 | 0.156126 | 0.156126 | 0.156126 | 1930.53 | 1930.53 | 2934.59 | 1.00 |
AIRLOOP F3 S1 DXAC HEAT PUMP | 0.227765 | 0.227765 | 0.227765 | 0.227765 | 2979.77 | 2979.77 | 2945.29 | 1.00 |
AIRLOOP F3 S2 DXAC HEAT PUMP | 0.229046 | 0.229046 | 0.229046 | 0.229046 | 2996.02 | 2996.02 | 2945.60 | 1.00 |
AIRLOOP F4 SW DXAC HEAT PUMP | 0.343027 | 0.343027 | 0.343027 | 0.343027 | 4314.11 | 4314.11 | 4220.93 | 1.00 |
AIRLOOP F4 NW DXAC HEAT PUMP | 0.307095 | 0.307095 | 0.307095 | 0.307095 | 3828.44 | 3828.44 | 4212.63 | 1.00 |
AIRLOOP F4 SE DXAC HEAT PUMP | 0.315321 | 0.315321 | 0.315321 | 0.315321 | 4033.64 | 4033.64 | 4227.77 | 1.00 |
AIRLOOP F4 NE DXAC HEAT PUMP | 0.230249 | 0.230249 | 0.230249 | 0.230249 | 2858.20 | 2858.20 | 4219.30 | 1.00 |
AIRLOOP F4 N1 DXAC HEAT PUMP | 0.159738 | 0.159738 | 0.159738 | 0.159738 | 1969.49 | 1969.49 | 2950.96 | 1.00 |
AIRLOOP F4 N2 DXAC HEAT PUMP | 0.158055 | 0.158055 | 0.158055 | 0.158055 | 1948.14 | 1948.14 | 2951.11 | 1.00 |
AIRLOOP F4 S1 DXAC HEAT PUMP | 0.230361 | 0.230361 | 0.230361 | 0.230361 | 3005.23 | 3005.23 | 2960.20 | 1.00 |
AIRLOOP F4 S2 DXAC HEAT PUMP | 0.231433 | 0.231433 | 0.231433 | 0.231433 | 3018.83 | 3018.83 | 2960.38 | 1.00 |
AIRLOOP M SW DXAC HEAT PUMP | 0.347132 | 0.347132 | 0.347132 | 0.347132 | 4383.03 | 4383.03 | 4254.28 | 1.00 |
AIRLOOP M NW DXAC HEAT PUMP | 0.310910 | 0.310910 | 0.310910 | 0.310910 | 3866.61 | 3866.61 | 4245.79 | 1.00 |
AIRLOOP M SE DXAC HEAT PUMP | 0.319896 | 0.319896 | 0.319896 | 0.319896 | 4081.51 | 4081.51 | 4260.57 | 1.00 |
AIRLOOP M NE DXAC HEAT PUMP | 0.234052 | 0.234052 | 0.234052 | 0.234052 | 2896.83 | 2896.83 | 4252.06 | 1.00 |
AIRLOOP M N1 DXAC HEAT PUMP | 0.163300 | 0.163300 | 0.163300 | 0.163300 | 2009.16 | 2009.16 | 2957.31 | 1.00 |
AIRLOOP M N2 DXAC HEAT PUMP | 0.161623 | 0.161623 | 0.161623 | 0.161623 | 1987.90 | 1987.90 | 2957.46 | 1.00 |
AIRLOOP M S1 DXAC HEAT PUMP | 0.234505 | 0.234505 | 0.234505 | 0.234505 | 3051.65 | 3051.65 | 2966.72 | 1.00 |
AIRLOOP M S2 DXAC HEAT PUMP | 0.235548 | 0.235548 | 0.235548 | 0.235548 | 3064.86 | 3064.86 | 2966.87 | 1.00 |
AIRLOOP F6 SW DXAC HEAT PUMP | 0.344778 | 0.344778 | 0.344778 | 0.344778 | 4344.62 | 4344.62 | 4347.20 | 1.00 |
AIRLOOP F6 NW DXAC HEAT PUMP | 0.308015 | 0.308015 | 0.308015 | 0.308015 | 3821.36 | 3821.36 | 4340.24 | 1.00 |
AIRLOOP F6 SE DXAC HEAT PUMP | 0.318048 | 0.318048 | 0.318048 | 0.318048 | 4049.74 | 4049.74 | 4353.07 | 1.00 |
AIRLOOP F6 NE DXAC HEAT PUMP | 0.231318 | 0.231318 | 0.231318 | 0.231318 | 2854.67 | 2854.67 | 4346.11 | 1.00 |
AIRLOOP F6 N1 DXAC HEAT PUMP | 0.160521 | 0.160521 | 0.160521 | 0.160521 | 1969.05 | 1969.05 | 3027.75 | 1.00 |
AIRLOOP F6 N2 DXAC HEAT PUMP | 0.158858 | 0.158858 | 0.158858 | 0.158858 | 1948.00 | 1948.00 | 3027.88 | 1.00 |
AIRLOOP F6 S1 DXAC HEAT PUMP | 0.232111 | 0.232111 | 0.232111 | 0.232111 | 3016.26 | 3016.26 | 3035.61 | 1.00 |
AIRLOOP F6 S2 DXAC HEAT PUMP | 0.233151 | 0.233151 | 0.233151 | 0.233151 | 3029.43 | 3029.43 | 3035.74 | 1.00 |
AIRLOOP F7 SW DXAC HEAT PUMP | 0.344630 | 0.344630 | 0.344630 | 0.344630 | 4335.21 | 4335.21 | 4412.86 | 1.00 |
AIRLOOP F7 NW DXAC HEAT PUMP | 0.307475 | 0.307475 | 0.307475 | 0.307475 | 3818.90 | 3818.90 | 4406.32 | 1.00 |
AIRLOOP F7 SE DXAC HEAT PUMP | 0.318340 | 0.318340 | 0.318340 | 0.318340 | 4046.06 | 4046.06 | 4418.31 | 1.00 |
AIRLOOP F7 NE DXAC HEAT PUMP | 0.230851 | 0.230851 | 0.230851 | 0.230851 | 2842.05 | 2842.05 | 4411.77 | 1.00 |
AIRLOOP F7 N1 DXAC HEAT PUMP | 0.159953 | 0.159953 | 0.159953 | 0.159953 | 1957.70 | 1957.70 | 3073.46 | 1.00 |
AIRLOOP F7 N2 DXAC HEAT PUMP | 0.158300 | 0.158300 | 0.158300 | 0.158300 | 1936.80 | 1936.80 | 3073.59 | 1.00 |
AIRLOOP F7 S1 DXAC HEAT PUMP | 0.231882 | 0.231882 | 0.231882 | 0.231882 | 3008.89 | 3008.89 | 3080.91 | 1.00 |
AIRLOOP F7 S2 DXAC HEAT PUMP | 0.232921 | 0.232921 | 0.232921 | 0.232921 | 3022.05 | 3022.05 | 3081.04 | 1.00 |
AIRLOOP F8 SW DXAC HEAT PUMP | 0.345641 | 0.345641 | 0.345641 | 0.345641 | 4341.23 | 4341.23 | 4487.91 | 1.00 |
AIRLOOP F8 NW DXAC HEAT PUMP | 0.308290 | 0.308290 | 0.308290 | 0.308290 | 3822.55 | 3822.55 | 4481.41 | 1.00 |
AIRLOOP F8 SE DXAC HEAT PUMP | 0.319701 | 0.319701 | 0.319701 | 0.319701 | 4056.66 | 4056.66 | 4492.95 | 1.00 |
AIRLOOP F8 NE DXAC HEAT PUMP | 0.231531 | 0.231531 | 0.231531 | 0.231531 | 2844.57 | 2844.57 | 4486.45 | 1.00 |
AIRLOOP F8 N1 DXAC HEAT PUMP | 0.160663 | 0.160663 | 0.160663 | 0.160663 | 1963.02 | 1963.02 | 3130.61 | 1.00 |
AIRLOOP F8 N2 DXAC HEAT PUMP | 0.159021 | 0.159021 | 0.159021 | 0.159021 | 1942.29 | 1942.29 | 3130.72 | 1.00 |
AIRLOOP F8 S1 DXAC HEAT PUMP | 0.232797 | 0.232797 | 0.232797 | 0.232797 | 3016.46 | 3016.46 | 3138.02 | 1.00 |
AIRLOOP F8 S2 DXAC HEAT PUMP | 0.233839 | 0.233839 | 0.233839 | 0.233839 | 3029.64 | 3029.64 | 3138.13 | 1.00 |
AIRLOOP F9 SW DXAC HEAT PUMP | 0.355198 | 0.355198 | 0.355198 | 0.355198 | 4455.68 | 4455.68 | 4745.45 | 1.00 |
AIRLOOP F9 NW DXAC HEAT PUMP | 0.318178 | 0.318178 | 0.318178 | 0.318178 | 3929.50 | 3929.50 | 4735.53 | 1.00 |
AIRLOOP F9 SE DXAC HEAT PUMP | 0.327431 | 0.327431 | 0.327431 | 0.327431 | 4148.48 | 4148.48 | 4750.14 | 1.00 |
AIRLOOP F9 NE DXAC HEAT PUMP | 0.234918 | 0.234918 | 0.234918 | 0.234918 | 2881.51 | 2881.51 | 4740.22 | 1.00 |
AIRLOOP F9 N1 DXAC HEAT PUMP | 0.169223 | 0.169223 | 0.169223 | 0.169223 | 2068.13 | 2068.13 | 3357.19 | 1.00 |
AIRLOOP F9 N2 DXAC HEAT PUMP | 0.167569 | 0.167569 | 0.167569 | 0.167569 | 2047.26 | 2047.26 | 3357.30 | 1.00 |
AIRLOOP F9 S1 DXAC HEAT PUMP | 0.239058 | 0.239058 | 0.239058 | 0.239058 | 3091.81 | 3091.81 | 3367.58 | 1.00 |
AIRLOOP F9 S2 DXAC HEAT PUMP | 0.240230 | 0.240230 | 0.240230 | 0.240230 | 3106.64 | 3106.64 | 3367.69 | 1.00 |
AIRLOOP T SW DXAC HEAT PUMP | 0.439596 | 0.439596 | 0.439596 | 0.439596 | 5539.38 | 5539.38 | 5755.41 | 1.00 |
AIRLOOP T NW DXAC HEAT PUMP | 0.384478 | 0.384478 | 0.384478 | 0.384478 | 4796.19 | 4796.19 | 5755.65 | 1.00 |
AIRLOOP T SE DXAC HEAT PUMP | 0.402413 | 0.402413 | 0.402413 | 0.402413 | 5089.00 | 5089.00 | 5759.44 | 1.00 |
AIRLOOP T NE DXAC HEAT PUMP | 0.294749 | 0.294749 | 0.294749 | 0.294749 | 3731.28 | 3731.28 | 5759.68 | 1.00 |
AIRLOOP T N1 DXAC HEAT PUMP | 0.222082 | 0.222082 | 0.222082 | 0.222082 | 2867.91 | 2867.91 | 4435.53 | 1.00 |
AIRLOOP T N2 DXAC HEAT PUMP | 0.221823 | 0.221823 | 0.221823 | 0.221823 | 2871.19 | 2871.19 | 4435.63 | 1.00 |
AIRLOOP T S1 DXAC HEAT PUMP | 0.325921 | 0.325921 | 0.325921 | 0.325921 | 4186.84 | 4186.84 | 4432.80 | 1.00 |
AIRLOOP T S2 DXAC HEAT PUMP | 0.327061 | 0.327061 | 0.327061 | 0.327061 | 4201.01 | 4201.01 | 4432.90 | 1.00 |
Maximum Flow Rate [m3/s] | |
AIRLOOP G SW SUPPLY FAN | 0.257918 |
AIRLOOP G NW SUPPLY FAN | 0.232276 |
AIRLOOP OFFICE SUPPLY FAN | 0.391958 |
AIRLOOP G NE SUPPLY FAN | 0.167596 |
AIRLOOP G N1 SUPPLY FAN | 0.115949 |
AIRLOOP G N2 SUPPLY FAN | 0.115956 |
AIRLOOP G S1 SUPPLY FAN | 0.165413 |
AIRLOOP G S2 SUPPLY FAN | 0.172810 |
AIRLOOP F2 SW SUPPLY FAN | 0.337846 |
AIRLOOP F2 NW SUPPLY FAN | 0.301073 |
AIRLOOP F2 SE SUPPLY FAN | 0.332695 |
AIRLOOP F2 NE SUPPLY FAN | 0.223056 |
AIRLOOP F2 N1 SUPPLY FAN | 0.152951 |
AIRLOOP F2 N2 SUPPLY FAN | 0.151254 |
AIRLOOP F2 S1 SUPPLY FAN | 0.221835 |
AIRLOOP F2 S2 SUPPLY FAN | 0.224574 |
AIRLOOP F3 SW SUPPLY FAN | 0.340896 |
AIRLOOP F3 NW SUPPLY FAN | 0.305105 |
AIRLOOP F3 SE SUPPLY FAN | 0.314353 |
AIRLOOP F3 NE SUPPLY FAN | 0.228348 |
AIRLOOP F3 N1 SUPPLY FAN | 0.157816 |
AIRLOOP F3 N2 SUPPLY FAN | 0.156126 |
AIRLOOP F3 S1 SUPPLY FAN | 0.227765 |
AIRLOOP F3 S2 SUPPLY FAN | 0.229046 |
AIRLOOP F4 SW SUPPLY FAN | 0.343027 |
AIRLOOP F4 NW SUPPLY FAN | 0.307095 |
AIRLOOP F4 SE SUPPLY FAN | 0.315321 |
AIRLOOP F4 NE SUPPLY FAN | 0.230249 |
AIRLOOP F4 N1 SUPPLY FAN | 0.159738 |
AIRLOOP F4 N2 SUPPLY FAN | 0.158055 |
AIRLOOP F4 S1 SUPPLY FAN | 0.230361 |
AIRLOOP F4 S2 SUPPLY FAN | 0.231433 |
AIRLOOP M SW SUPPLY FAN | 0.347132 |
AIRLOOP M NW SUPPLY FAN | 0.310910 |
AIRLOOP M SE SUPPLY FAN | 0.319896 |
AIRLOOP M NE SUPPLY FAN | 0.234052 |
AIRLOOP M N1 SUPPLY FAN | 0.163300 |
AIRLOOP M N2 SUPPLY FAN | 0.161623 |
AIRLOOP M S1 SUPPLY FAN | 0.234505 |
AIRLOOP M S2 SUPPLY FAN | 0.235548 |
AIRLOOP F6 SW SUPPLY FAN | 0.344778 |
AIRLOOP F6 NW SUPPLY FAN | 0.308015 |
AIRLOOP F6 SE SUPPLY FAN | 0.318048 |
AIRLOOP F6 NE SUPPLY FAN | 0.231318 |
AIRLOOP F6 N1 SUPPLY FAN | 0.160521 |
AIRLOOP F6 N2 SUPPLY FAN | 0.158858 |
AIRLOOP F6 S1 SUPPLY FAN | 0.232111 |
AIRLOOP F6 S2 SUPPLY FAN | 0.233151 |
AIRLOOP F7 SW SUPPLY FAN | 0.344630 |
AIRLOOP F7 NW SUPPLY FAN | 0.307475 |
AIRLOOP F7 SE SUPPLY FAN | 0.318340 |
AIRLOOP F7 NE SUPPLY FAN | 0.230851 |
AIRLOOP F7 N1 SUPPLY FAN | 0.159953 |
AIRLOOP F7 N2 SUPPLY FAN | 0.158300 |
AIRLOOP F7 S1 SUPPLY FAN | 0.231882 |
AIRLOOP F7 S2 SUPPLY FAN | 0.232921 |
AIRLOOP F8 SW SUPPLY FAN | 0.345641 |
AIRLOOP F8 NW SUPPLY FAN | 0.308290 |
AIRLOOP F8 SE SUPPLY FAN | 0.319701 |
AIRLOOP F8 NE SUPPLY FAN | 0.231531 |
AIRLOOP F8 N1 SUPPLY FAN | 0.160663 |
AIRLOOP F8 N2 SUPPLY FAN | 0.159021 |
AIRLOOP F8 S1 SUPPLY FAN | 0.232797 |
AIRLOOP F8 S2 SUPPLY FAN | 0.233839 |
AIRLOOP F9 SW SUPPLY FAN | 0.355198 |
AIRLOOP F9 NW SUPPLY FAN | 0.318178 |
AIRLOOP F9 SE SUPPLY FAN | 0.327431 |
AIRLOOP F9 NE SUPPLY FAN | 0.234918 |
AIRLOOP F9 N1 SUPPLY FAN | 0.169223 |
AIRLOOP F9 N2 SUPPLY FAN | 0.167569 |
AIRLOOP F9 S1 SUPPLY FAN | 0.239058 |
AIRLOOP F9 S2 SUPPLY FAN | 0.240230 |
AIRLOOP T SW SUPPLY FAN | 0.439596 |
AIRLOOP T NW SUPPLY FAN | 0.384478 |
AIRLOOP T SE SUPPLY FAN | 0.402413 |
AIRLOOP T NE SUPPLY FAN | 0.294749 |
AIRLOOP T N1 SUPPLY FAN | 0.222082 |
AIRLOOP T N2 SUPPLY FAN | 0.221823 |
AIRLOOP T S1 SUPPLY FAN | 0.325921 |
AIRLOOP T S2 SUPPLY FAN | 0.327061 |
Rated Air Flow Rate [m3/s] | Rated Heating Capacity [W] | Rated Water Flow Rate [m3/s] | |
HEAT PUMP HEATING MODE AIRLOOP G SW | 0.257918 | 3320.88 | 0.000073 |
HEAT PUMP HEATING MODE AIRLOOP G NW | 0.232276 | 2936.09 | 0.000064 |
HEAT PUMP HEATING MODE AIRLOOP OFFICE | 0.391958 | 5108.72 | 0.000112 |
HEAT PUMP HEATING MODE AIRLOOP G NE | 0.167596 | 2103.58 | 0.000046 |
HEAT PUMP HEATING MODE AIRLOOP G N1 | 0.115949 | 1439.44 | 0.000031 |
HEAT PUMP HEATING MODE AIRLOOP G N2 | 0.115956 | 1438.70 | 0.000031 |
HEAT PUMP HEATING MODE AIRLOOP G S1 | 0.165413 | 2215.71 | 0.000048 |
HEAT PUMP HEATING MODE AIRLOOP G S2 | 0.172810 | 2309.38 | 0.000050 |
HEAT PUMP HEATING MODE AIRLOOP F2 SW | 0.337846 | 4269.83 | 0.000093 |
HEAT PUMP HEATING MODE AIRLOOP F2 NW | 0.301073 | 3781.51 | 0.000083 |
HEAT PUMP HEATING MODE AIRLOOP F2 SE | 0.332695 | 4282.48 | 0.000094 |
HEAT PUMP HEATING MODE AIRLOOP F2 NE | 0.223056 | 2777.62 | 0.000061 |
HEAT PUMP HEATING MODE AIRLOOP F2 N1 | 0.152951 | 1899.41 | 0.000041 |
HEAT PUMP HEATING MODE AIRLOOP F2 N2 | 0.151254 | 1877.81 | 0.000041 |
HEAT PUMP HEATING MODE AIRLOOP F2 S1 | 0.221835 | 2914.54 | 0.000064 |
HEAT PUMP HEATING MODE AIRLOOP F2 S2 | 0.224574 | 2949.27 | 0.000064 |
HEAT PUMP HEATING MODE AIRLOOP F3 SW | 0.340896 | 4299.74 | 0.000094 |
HEAT PUMP HEATING MODE AIRLOOP F3 NW | 0.305105 | 3815.75 | 0.000083 |
HEAT PUMP HEATING MODE AIRLOOP F3 SE | 0.314353 | 4033.67 | 0.000088 |
HEAT PUMP HEATING MODE AIRLOOP F3 NE | 0.228348 | 2828.81 | 0.000062 |
HEAT PUMP HEATING MODE AIRLOOP F3 N1 | 0.157816 | 1952.00 | 0.000043 |
HEAT PUMP HEATING MODE AIRLOOP F3 N2 | 0.156126 | 1930.53 | 0.000042 |
HEAT PUMP HEATING MODE AIRLOOP F3 S1 | 0.227765 | 2979.77 | 0.000065 |
HEAT PUMP HEATING MODE AIRLOOP F3 S2 | 0.229046 | 2996.02 | 0.000065 |
HEAT PUMP HEATING MODE AIRLOOP F4 SW | 0.343027 | 4314.11 | 0.000094 |
HEAT PUMP HEATING MODE AIRLOOP F4 NW | 0.307095 | 3828.44 | 0.000084 |
HEAT PUMP HEATING MODE AIRLOOP F4 SE | 0.315321 | 4033.64 | 0.000088 |
HEAT PUMP HEATING MODE AIRLOOP F4 NE | 0.230249 | 2858.20 | 0.000062 |
HEAT PUMP HEATING MODE AIRLOOP F4 N1 | 0.159738 | 1969.49 | 0.000043 |
HEAT PUMP HEATING MODE AIRLOOP F4 N2 | 0.158055 | 1948.14 | 0.000043 |
HEAT PUMP HEATING MODE AIRLOOP F4 S1 | 0.230361 | 3005.23 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP F4 S2 | 0.231433 | 3018.83 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP M SW | 0.347132 | 4383.03 | 0.000096 |
HEAT PUMP HEATING MODE AIRLOOP M NW | 0.310910 | 3866.61 | 0.000084 |
HEAT PUMP HEATING MODE AIRLOOP M SE | 0.319896 | 4081.51 | 0.000089 |
HEAT PUMP HEATING MODE AIRLOOP M NE | 0.234052 | 2896.83 | 0.000063 |
HEAT PUMP HEATING MODE AIRLOOP M N1 | 0.163300 | 2009.16 | 0.000044 |
HEAT PUMP HEATING MODE AIRLOOP M N2 | 0.161623 | 1987.90 | 0.000043 |
HEAT PUMP HEATING MODE AIRLOOP M S1 | 0.234505 | 3051.65 | 0.000067 |
HEAT PUMP HEATING MODE AIRLOOP M S2 | 0.235548 | 3064.86 | 0.000067 |
HEAT PUMP HEATING MODE AIRLOOP F6 SW | 0.344778 | 4344.62 | 0.000095 |
HEAT PUMP HEATING MODE AIRLOOP F6 NW | 0.308015 | 3821.36 | 0.000083 |
HEAT PUMP HEATING MODE AIRLOOP F6 SE | 0.318048 | 4049.74 | 0.000088 |
HEAT PUMP HEATING MODE AIRLOOP F6 NE | 0.231318 | 2854.67 | 0.000062 |
HEAT PUMP HEATING MODE AIRLOOP F6 N1 | 0.160521 | 1969.05 | 0.000043 |
HEAT PUMP HEATING MODE AIRLOOP F6 N2 | 0.158858 | 1948.00 | 0.000043 |
HEAT PUMP HEATING MODE AIRLOOP F6 S1 | 0.232111 | 3016.26 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP F6 S2 | 0.233151 | 3029.43 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP F7 SW | 0.344630 | 4335.21 | 0.000095 |
HEAT PUMP HEATING MODE AIRLOOP F7 NW | 0.307475 | 3818.90 | 0.000083 |
HEAT PUMP HEATING MODE AIRLOOP F7 SE | 0.318340 | 4046.06 | 0.000088 |
HEAT PUMP HEATING MODE AIRLOOP F7 NE | 0.230851 | 2842.05 | 0.000062 |
HEAT PUMP HEATING MODE AIRLOOP F7 N1 | 0.159953 | 1957.70 | 0.000043 |
HEAT PUMP HEATING MODE AIRLOOP F7 N2 | 0.158300 | 1936.80 | 0.000042 |
HEAT PUMP HEATING MODE AIRLOOP F7 S1 | 0.231882 | 3008.89 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP F7 S2 | 0.232921 | 3022.05 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP F8 SW | 0.345641 | 4341.23 | 0.000095 |
HEAT PUMP HEATING MODE AIRLOOP F8 NW | 0.308290 | 3822.55 | 0.000084 |
HEAT PUMP HEATING MODE AIRLOOP F8 SE | 0.319701 | 4056.66 | 0.000089 |
HEAT PUMP HEATING MODE AIRLOOP F8 NE | 0.231531 | 2844.57 | 0.000062 |
HEAT PUMP HEATING MODE AIRLOOP F8 N1 | 0.160663 | 1963.02 | 0.000043 |
HEAT PUMP HEATING MODE AIRLOOP F8 N2 | 0.159021 | 1942.29 | 0.000042 |
HEAT PUMP HEATING MODE AIRLOOP F8 S1 | 0.232797 | 3016.46 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP F8 S2 | 0.233839 | 3029.64 | 0.000066 |
HEAT PUMP HEATING MODE AIRLOOP F9 SW | 0.355198 | 4455.68 | 0.000097 |
HEAT PUMP HEATING MODE AIRLOOP F9 NW | 0.318178 | 3929.50 | 0.000086 |
HEAT PUMP HEATING MODE AIRLOOP F9 SE | 0.327431 | 4148.48 | 0.000091 |
HEAT PUMP HEATING MODE AIRLOOP F9 NE | 0.234918 | 2881.51 | 0.000063 |
HEAT PUMP HEATING MODE AIRLOOP F9 N1 | 0.169223 | 2068.13 | 0.000045 |
HEAT PUMP HEATING MODE AIRLOOP F9 N2 | 0.167569 | 2047.26 | 0.000045 |
HEAT PUMP HEATING MODE AIRLOOP F9 S1 | 0.239058 | 3091.81 | 0.000068 |
HEAT PUMP HEATING MODE AIRLOOP F9 S2 | 0.240230 | 3106.64 | 0.000068 |
HEAT PUMP HEATING MODE AIRLOOP T SW | 0.439596 | 5539.38 | 0.000121 |
HEAT PUMP HEATING MODE AIRLOOP T NW | 0.384478 | 4796.19 | 0.000105 |
HEAT PUMP HEATING MODE AIRLOOP T SE | 0.402413 | 5089.00 | 0.000111 |
HEAT PUMP HEATING MODE AIRLOOP T NE | 0.294749 | 3731.28 | 0.000082 |
HEAT PUMP HEATING MODE AIRLOOP T N1 | 0.222082 | 2867.91 | 0.000063 |
HEAT PUMP HEATING MODE AIRLOOP T N2 | 0.221823 | 2871.19 | 0.000063 |
HEAT PUMP HEATING MODE AIRLOOP T S1 | 0.325921 | 4186.84 | 0.000091 |
HEAT PUMP HEATING MODE AIRLOOP T S2 | 0.327061 | 4201.01 | 0.000092 |
Nominal Capacity [W] | |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW | 4530.04 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW | 4530.57 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE | 5570.62 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE | 4536.36 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 | 3542.17 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 | 3542.30 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 | 3539.28 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 | 3545.68 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW | 4219.43 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW | 4207.11 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE | 4244.62 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE | 4214.24 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 | 3017.74 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 | 3017.90 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 | 3033.24 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 | 3034.50 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW | 4172.14 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW | 4162.51 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE | 4180.94 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE | 4169.50 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 | 2934.43 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 | 2934.59 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 | 2945.29 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 | 2945.60 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW | 4220.93 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW | 4212.63 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE | 4227.77 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE | 4219.30 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 | 2950.96 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 | 2951.11 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 | 2960.20 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 | 2960.38 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW | 4254.28 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW | 4245.79 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE | 4260.57 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE | 4252.06 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 | 2957.31 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 | 2957.46 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 | 2966.72 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 | 2966.87 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW | 4347.20 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW | 4340.24 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE | 4353.07 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE | 4346.11 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 | 3027.75 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 | 3027.88 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 | 3035.61 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 | 3035.74 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW | 4412.86 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW | 4406.32 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE | 4418.31 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE | 4411.77 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 | 3073.46 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 | 3073.59 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 | 3080.91 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 | 3081.04 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW | 4487.91 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW | 4481.41 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE | 4492.95 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE | 4486.45 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 | 3130.61 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 | 3130.72 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 | 3138.02 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 | 3138.13 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW | 4745.45 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW | 4735.53 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE | 4750.14 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE | 4740.22 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 | 3357.19 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 | 3357.30 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 | 3367.58 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 | 3367.69 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW | 5755.41 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW | 5755.65 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE | 5759.44 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE | 5759.68 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 | 4435.53 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 | 4435.63 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 | 4432.80 |
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 | 4432.90 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
SHWSYS1 | 0.000289 | 0.325214 |
SINGLE WATER PLANT LOOP | 0.005566 | 6.26 |
Design Water Flow Rate [m3/s] | |
CENTRAL BOILER | 0.005566 |
Use Side Design Flow Rate [m3/s] | |
SHWSYS1 WATER HEATER | 0.000289 |
Design Water Flow Rate [m3/s] | Fan Power at Design Air Flow Rate [W] | Design Air Flow Rate [m3/s] | U-Factor Times Area Value at Design Air Flow Rate [W/C] | |
CENTRAL TOWER | 0.005566 | 2687.03 | 8.14 | 7240.83 |
Rated Flow Rate [m3/s] | Rated Power Consumption [W] | |
SHWSYS1 PUMP | 0.000289 | 36.93 |
PLANT CIRC PUMP | 0.005566 | 1777.54 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:13
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW3 | |
G WWALL SWA | GWINDOW2 | |
G NWALL NWA | GWINDOW4 | |
G WWALL NWA | GWINDOW6 | |
G SWALL SEA | GWINDOW1 | |
G EWALL SEA | GWINDOW8 | |
G NWALL NEA | GWINDOW5 | |
G EWALL NEA | GWINDOW7 | |
G NWALL N1A | GWINDOW9 | |
G NWALL N2A | GWINDOW10 | |
G SWALL S1A | GWINDOW11 | |
G SWALL S2A | GWINDOW12 | |
G WWALL C | GWINDOW13 | |
G EWALL C | ENTRANCE DOOR | |
F2 WWALL SWA | F2WINDOW2 | |
F2 SWALL SWA | F2WINDOW3 | |
F2 NWALL NWA | F2WINDOW4 | |
F2 WWALL NWA | F2WINDOW6 | |
F2 EWALL SEA | F2WINDOW8 | |
F2 SWALL SEA | F2WINDOW1 | |
F2 NWALL NEA | F2WINDOW5 | |
F2 EWALL NEA | F2WINDOW7 | |
F2 NWALL N1A | F2WINDOW9 | |
F2 NWALL N2A | F2WINDOW10 | |
F2 SWALL S1A | F2WINDOW11 | |
F2 SWALL S2A | F2WINDOW12 | |
F2 WWALL C | F2WINDOW13 | |
F2 EWALL C | F2WINDOW14 | |
F3 WWALL SWA | F3WINDOW2 | |
F3 SWALL SWA | F3WINDOW3 | |
F3 NWALL NWA | F3WINDOW4 | |
F3 WWALL NWA | F3WINDOW6 | |
F3 EWALL SEA | F3WINDOW8 | |
F3 SWALL SEA | F3WINDOW1 | |
F3 NWALL NEA | F3WINDOW5 | |
F3 EWALL NEA | F3WINDOW7 | |
F3 NWALL N1A | F3WINDOW9 | |
F3 NWALL N2A | F3WINDOW10 | |
F3 SWALL S1A | F3WINDOW11 | |
F3 SWALL S2A | F3WINDOW12 | |
F3 WWALL C | F3WINDOW13 | |
F3 EWALL C | F3WINDOW14 | |
F4 WWALL SWA | F4WINDOW2 | |
F4 SWALL SWA | F4WINDOW3 | |
F4 NWALL NWA | F4WINDOW4 | |
F4 WWALL NWA | F4WINDOW6 | |
F4 EWALL SEA | F4WINDOW8 | |
F4 SWALL SEA | F4WINDOW1 | |
F4 NWALL NEA | F4WINDOW5 | |
F4 EWALL NEA | F4WINDOW7 | |
F4 NWALL N1A | F4WINDOW9 | |
F4 NWALL N2A | F4WINDOW10 | |
F4 SWALL S1A | F4WINDOW11 | |
F4 SWALL S2A | F4WINDOW12 | |
F4 WWALL C | F4WINDOW13 | |
F4 EWALL C | F4WINDOW14 | |
M WWALL SWA | MWINDOW2 | |
M SWALL SWA | MWINDOW3 | |
M NWALL NWA | MWINDOW4 | |
M WWALL NWA | MWINDOW6 | |
M EWALL SEA | MWINDOW8 | |
M SWALL SEA | MWINDOW1 | |
M NWALL NEA | MWINDOW5 | |
M EWALL NEA | MWINDOW7 | |
M NWALL N1A | MWINDOW9 | |
M NWALL N2A | MWINDOW10 | |
M SWALL S1A | MWINDOW11 | |
M SWALL S2A | MWINDOW12 | |
M WWALL C | MWINDOW13 | |
M EWALL C | MWINDOW14 | |
F6 WWALL SWA | F6WINDOW2 | |
F6 SWALL SWA | F6WINDOW3 | |
F6 NWALL NWA | F6WINDOW4 | |
F6 WWALL NWA | F6WINDOW6 | |
F6 EWALL SEA | F6WINDOW8 | |
F6 SWALL SEA | F6WINDOW1 | |
F6 NWALL NEA | F6WINDOW5 | |
F6 EWALL NEA | F6WINDOW7 | |
F6 NWALL N1A | F6WINDOW9 | |
F6 NWALL N2A | F6WINDOW10 | |
F6 SWALL S1A | F6WINDOW11 | |
F6 SWALL S2A | F6WINDOW12 | |
F6 WWALL C | F6WINDOW13 | |
F6 EWALL C | F6WINDOW14 | |
F7 WWALL SWA | F7WINDOW2 | |
F7 SWALL SWA | F7WINDOW3 | |
F7 NWALL NWA | F7WINDOW4 | |
F7 WWALL NWA | F7WINDOW6 | |
F7 EWALL SEA | F7WINDOW8 | |
F7 SWALL SEA | F7WINDOW1 | |
F7 NWALL NEA | F7WINDOW5 | |
F7 EWALL NEA | F7WINDOW7 | |
F7 NWALL N1A | F7WINDOW9 | |
F7 NWALL N2A | F7WINDOW10 | |
F7 SWALL S1A | F7WINDOW11 | |
F7 SWALL S2A | F7WINDOW12 | |
F7 WWALL C | F7WINDOW13 | |
F7 EWALL C | F7WINDOW14 | |
F8 WWALL SWA | F8WINDOW2 | |
F8 SWALL SWA | F8WINDOW3 | |
F8 NWALL NWA | F8WINDOW4 | |
F8 WWALL NWA | F8WINDOW6 | |
F8 EWALL SEA | F8WINDOW8 | |
F8 SWALL SEA | F8WINDOW1 | |
F8 NWALL NEA | F8WINDOW5 | |
F8 EWALL NEA | F8WINDOW7 | |
F8 NWALL N1A | F8WINDOW9 | |
F8 NWALL N2A | F8WINDOW10 | |
F8 SWALL S1A | F8WINDOW11 | |
F8 SWALL S2A | F8WINDOW12 | |
F8 WWALL C | F8WINDOW13 | |
F8 EWALL C | F8WINDOW14 | |
F9 WWALL SWA | F9WINDOW2 | |
F9 SWALL SWA | F9WINDOW3 | |
F9 NWALL NWA | F9WINDOW4 | |
F9 WWALL NWA | F9WINDOW6 | |
F9 EWALL SEA | F9WINDOW8 | |
F9 SWALL SEA | F9WINDOW1 | |
F9 NWALL NEA | F9WINDOW5 | |
F9 EWALL NEA | F9WINDOW7 | |
F9 NWALL N1A | F9WINDOW9 | |
F9 NWALL N2A | F9WINDOW10 | |
F9 SWALL S1A | F9WINDOW11 | |
F9 SWALL S2A | F9WINDOW12 | |
F9 WWALL C | F9WINDOW13 | |
F9 EWALL C | F9WINDOW14 | |
T WWALL SWA | TWINDOW2 | |
T SWALL SWA | TWINDOW3 | |
T NWALL NWA | TWINDOW4 | |
T WWALL NWA | TWINDOW6 | |
T EWALL SEA | TWINDOW8 | |
T SWALL SEA | TWINDOW1 | |
T NWALL NEA | TWINDOW5 | |
T EWALL NEA | TWINDOW7 | |
T NWALL N1A | TWINDOW9 | |
T NWALL N2A | TWINDOW10 | |
T SWALL S1A | TWINDOW11 | |
T SWALL S2A | TWINDOW12 | |
T WWALL C | TWINDOW13 | |
T EWALL C | TWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2015-09-09 19:11:13
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.76 | -4.7 |
February | 21.84 | -3.7 |
March | 22.07 | 2.15 |
April | 22.45 | 6.19 |
May | 22.93 | 11.83 |
June | 24.05 | 17.35 |
July | 24.27 | 20.52 |
August | 24.22 | 18.54 |
September | 24.04 | 14.70 |
October | 22.62 | 6.26 |
November | 21.97 | 1.12 |
December | 21.78 | -5.0 |
Annual Sum or Average | 22.84 | 7.16 |
Minimum of Months | 21.76 | -5.0 |
Maximum of Months | 24.27 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.75 | 2.15 |
April | 21.99 | 6.19 |
May | 22.65 | 11.83 |
June | 23.99 | 17.35 |
July | 24.26 | 20.52 |
August | 24.12 | 18.54 |
September | 23.72 | 14.70 |
October | 21.94 | 6.26 |
November | 21.72 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.61 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.26 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.00 | -4.7 |
February | 22.05 | -3.7 |
March | 22.44 | 2.15 |
April | 22.83 | 6.19 |
May | 23.44 | 11.83 |
June | 24.26 | 17.35 |
July | 24.38 | 20.52 |
August | 24.36 | 18.54 |
September | 24.16 | 14.70 |
October | 22.87 | 6.26 |
November | 22.29 | 1.12 |
December | 21.93 | -5.0 |
Annual Sum or Average | 23.09 | 7.16 |
Minimum of Months | 21.93 | -5.0 |
Maximum of Months | 24.38 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.72 | 2.15 |
April | 21.90 | 6.19 |
May | 22.62 | 11.83 |
June | 23.93 | 17.35 |
July | 24.27 | 20.52 |
August | 24.10 | 18.54 |
September | 23.62 | 14.70 |
October | 21.85 | 6.26 |
November | 21.71 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.57 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.27 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.71 | 2.15 |
April | 21.81 | 6.19 |
May | 22.34 | 11.83 |
June | 23.80 | 17.35 |
July | 24.20 | 20.52 |
August | 24.02 | 18.54 |
September | 23.59 | 14.70 |
October | 21.82 | 6.26 |
November | 21.71 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.51 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.20 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.71 | 2.15 |
April | 21.81 | 6.19 |
May | 22.35 | 11.83 |
June | 23.80 | 17.35 |
July | 24.20 | 20.52 |
August | 24.03 | 18.54 |
September | 23.59 | 14.70 |
October | 21.82 | 6.26 |
November | 21.71 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.51 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.20 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.78 | -4.7 |
February | 21.84 | -3.7 |
March | 22.06 | 2.15 |
April | 22.36 | 6.19 |
May | 22.77 | 11.83 |
June | 23.98 | 17.35 |
July | 24.25 | 20.52 |
August | 24.20 | 18.54 |
September | 24.10 | 14.70 |
October | 22.70 | 6.26 |
November | 22.02 | 1.12 |
December | 21.80 | -5.0 |
Annual Sum or Average | 22.83 | 7.16 |
Minimum of Months | 21.78 | -5.0 |
Maximum of Months | 24.25 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.79 | -4.7 |
February | 21.85 | -3.7 |
March | 22.09 | 2.15 |
April | 22.42 | 6.19 |
May | 22.84 | 11.83 |
June | 24.02 | 17.35 |
July | 24.26 | 20.52 |
August | 24.22 | 18.54 |
September | 24.13 | 14.70 |
October | 22.74 | 6.26 |
November | 22.05 | 1.12 |
December | 21.81 | -5.0 |
Annual Sum or Average | 22.86 | 7.16 |
Minimum of Months | 21.79 | -5.0 |
Maximum of Months | 24.26 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 14.55 | -4.7 |
February | 14.90 | -3.7 |
March | 16.89 | 2.15 |
April | 18.40 | 6.19 |
May | 20.54 | 11.83 |
June | 23.35 | 17.35 |
July | 24.74 | 20.52 |
August | 24.00 | 18.54 |
September | 22.51 | 14.70 |
October | 18.50 | 6.26 |
November | 16.46 | 1.12 |
December | 14.40 | -5.0 |
Annual Sum or Average | 19.13 | 7.16 |
Minimum of Months | 14.40 | -5.0 |
Maximum of Months | 24.74 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F2 SW APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.84 | -4.7 |
February | 22.04 | -3.7 |
March | 22.47 | 2.15 |
April | 23.08 | 6.19 |
May | 23.71 | 11.83 |
June | 24.31 | 17.35 |
July | 24.36 | 20.52 |
August | 24.34 | 18.54 |
September | 24.26 | 14.70 |
October | 23.24 | 6.26 |
November | 22.24 | 1.12 |
December | 21.87 | -5.0 |
Annual Sum or Average | 23.15 | 7.16 |
Minimum of Months | 21.84 | -5.0 |
Maximum of Months | 24.36 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F2 NW APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.71 | -3.7 |
March | 21.82 | 2.15 |
April | 22.35 | 6.19 |
May | 23.36 | 11.83 |
June | 24.26 | 17.35 |
July | 24.35 | 20.52 |
August | 24.29 | 18.54 |
September | 23.98 | 14.70 |
October | 22.20 | 6.26 |
November | 21.76 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.80 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.35 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F2 SE APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.88 | -4.7 |
February | 22.08 | -3.7 |
March | 22.56 | 2.15 |
April | 23.26 | 6.19 |
May | 23.85 | 11.83 |
June | 24.35 | 17.35 |
July | 24.38 | 20.52 |
August | 24.37 | 18.54 |
September | 24.29 | 14.70 |
October | 23.33 | 6.26 |
November | 22.32 | 1.12 |
December | 21.90 | -5.0 |
Annual Sum or Average | 23.22 | 7.16 |
Minimum of Months | 21.88 | -5.0 |
Maximum of Months | 24.38 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F2 NE APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.77 | 2.15 |
April | 22.25 | 6.19 |
May | 23.28 | 11.83 |
June | 24.23 | 17.35 |
July | 24.36 | 20.52 |
August | 24.28 | 18.54 |
September | 23.88 | 14.70 |
October | 22.07 | 6.26 |
November | 21.73 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.75 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.36 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F2 N1 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.75 | 2.15 |
April | 22.09 | 6.19 |
May | 23.09 | 11.83 |
June | 24.16 | 17.35 |
July | 24.32 | 20.52 |
August | 24.24 | 18.54 |
September | 23.90 | 14.70 |
October | 22.05 | 6.26 |
November | 21.75 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.71 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.32 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F2 N2 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.75 | 2.15 |
April | 22.09 | 6.19 |
May | 23.09 | 11.83 |
June | 24.16 | 17.35 |
July | 24.32 | 20.52 |
August | 24.24 | 18.54 |
September | 23.89 | 14.70 |
October | 22.04 | 6.26 |
November | 21.75 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.71 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.32 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F2 S1 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.93 | -4.7 |
February | 22.15 | -3.7 |
March | 22.58 | 2.15 |
April | 23.15 | 6.19 |
May | 23.69 | 11.83 |
June | 24.27 | 17.35 |
July | 24.35 | 20.52 |
August | 24.33 | 18.54 |
September | 24.31 | 14.70 |
October | 23.42 | 6.26 |
November | 22.45 | 1.12 |
December | 21.97 | -5.0 |
Annual Sum or Average | 23.22 | 7.16 |
Minimum of Months | 21.93 | -5.0 |
Maximum of Months | 24.35 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F2 S2 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.94 | -4.7 |
February | 22.16 | -3.7 |
March | 22.60 | 2.15 |
April | 23.18 | 6.19 |
May | 23.72 | 11.83 |
June | 24.28 | 17.35 |
July | 24.35 | 20.52 |
August | 24.34 | 18.54 |
September | 24.32 | 14.70 |
October | 23.44 | 6.26 |
November | 22.47 | 1.12 |
December | 21.98 | -5.0 |
Annual Sum or Average | 23.24 | 7.16 |
Minimum of Months | 21.94 | -5.0 |
Maximum of Months | 24.35 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F2 CORRIDOR
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.16 | -4.7 |
February | 21.54 | -3.7 |
March | 22.29 | 2.15 |
April | 23.19 | 6.19 |
May | 24.42 | 11.83 |
June | 25.82 | 17.35 |
July | 26.28 | 20.52 |
August | 26.01 | 18.54 |
September | 25.44 | 14.70 |
October | 23.23 | 6.26 |
November | 21.96 | 1.12 |
December | 21.11 | -5.0 |
Annual Sum or Average | 23.55 | 7.16 |
Minimum of Months | 21.11 | -5.0 |
Maximum of Months | 26.28 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F3 SW APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.86 | -4.7 |
February | 22.09 | -3.7 |
March | 22.54 | 2.15 |
April | 23.19 | 6.19 |
May | 23.80 | 11.83 |
June | 24.32 | 17.35 |
July | 24.36 | 20.52 |
August | 24.35 | 18.54 |
September | 24.28 | 14.70 |
October | 23.36 | 6.26 |
November | 22.30 | 1.12 |
December | 21.89 | -5.0 |
Annual Sum or Average | 23.20 | 7.16 |
Minimum of Months | 21.86 | -5.0 |
Maximum of Months | 24.36 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F3 NW APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.71 | -3.7 |
March | 21.84 | 2.15 |
April | 22.43 | 6.19 |
May | 23.47 | 11.83 |
June | 24.28 | 17.35 |
July | 24.35 | 20.52 |
August | 24.30 | 18.54 |
September | 24.00 | 14.70 |
October | 22.29 | 6.26 |
November | 21.78 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.83 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.35 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F3 SE APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.85 | -4.7 |
February | 22.07 | -3.7 |
March | 22.52 | 2.15 |
April | 23.23 | 6.19 |
May | 23.84 | 11.83 |
June | 24.33 | 17.35 |
July | 24.38 | 20.52 |
August | 24.36 | 18.54 |
September | 24.26 | 14.70 |
October | 23.34 | 6.26 |
November | 22.27 | 1.12 |
December | 21.88 | -5.0 |
Annual Sum or Average | 23.20 | 7.16 |
Minimum of Months | 21.85 | -5.0 |
Maximum of Months | 24.38 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F3 NE APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.78 | 2.15 |
April | 22.34 | 6.19 |
May | 23.39 | 11.83 |
June | 24.25 | 17.35 |
July | 24.36 | 20.52 |
August | 24.29 | 18.54 |
September | 23.91 | 14.70 |
October | 22.15 | 6.26 |
November | 21.75 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.78 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.36 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F3 N1 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.77 | 2.15 |
April | 22.21 | 6.19 |
May | 23.28 | 11.83 |
June | 24.21 | 17.35 |
July | 24.33 | 20.52 |
August | 24.26 | 18.54 |
September | 23.95 | 14.70 |
October | 22.17 | 6.26 |
November | 21.77 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.76 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.33 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F3 N2 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.77 | 2.15 |
April | 22.21 | 6.19 |
May | 23.28 | 11.83 |
June | 24.21 | 17.35 |
July | 24.33 | 20.52 |
August | 24.26 | 18.54 |
September | 23.94 | 14.70 |
October | 22.16 | 6.26 |
November | 21.77 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.76 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.33 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F3 S1 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.98 | -4.7 |
February | 22.28 | -3.7 |
March | 22.74 | 2.15 |
April | 23.35 | 6.19 |
May | 23.86 | 11.83 |
June | 24.29 | 17.35 |
July | 24.35 | 20.52 |
August | 24.34 | 18.54 |
September | 24.34 | 14.70 |
October | 23.59 | 6.26 |
November | 22.58 | 1.12 |
December | 22.03 | -5.0 |
Annual Sum or Average | 23.32 | 7.16 |
Minimum of Months | 21.98 | -5.0 |
Maximum of Months | 24.35 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F3 S2 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.99 | -4.7 |
February | 22.28 | -3.7 |
March | 22.74 | 2.15 |
April | 23.36 | 6.19 |
May | 23.87 | 11.83 |
June | 24.29 | 17.35 |
July | 24.35 | 20.52 |
August | 24.34 | 18.54 |
September | 24.34 | 14.70 |
October | 23.60 | 6.26 |
November | 22.58 | 1.12 |
December | 22.03 | -5.0 |
Annual Sum or Average | 23.32 | 7.16 |
Minimum of Months | 21.99 | -5.0 |
Maximum of Months | 24.35 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F3 CORRIDOR
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.78 | -4.7 |
February | 22.17 | -3.7 |
March | 22.83 | 2.15 |
April | 23.73 | 6.19 |
May | 24.92 | 11.83 |
June | 26.08 | 17.35 |
July | 26.44 | 20.52 |
August | 26.21 | 18.54 |
September | 25.71 | 14.70 |
October | 23.76 | 6.26 |
November | 22.48 | 1.12 |
December | 21.71 | -5.0 |
Annual Sum or Average | 23.99 | 7.16 |
Minimum of Months | 21.71 | -5.0 |
Maximum of Months | 26.44 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F4 SW APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.86 | -4.7 |
February | 22.09 | -3.7 |
March | 22.52 | 2.15 |
April | 23.18 | 6.19 |
May | 23.79 | 11.83 |
June | 24.32 | 17.35 |
July | 24.36 | 20.52 |
August | 24.35 | 18.54 |
September | 24.27 | 14.70 |
October | 23.37 | 6.26 |
November | 22.29 | 1.12 |
December | 21.88 | -5.0 |
Annual Sum or Average | 23.20 | 7.16 |
Minimum of Months | 21.86 | -5.0 |
Maximum of Months | 24.36 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F4 NW APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.71 | -3.7 |
March | 21.84 | 2.15 |
April | 22.44 | 6.19 |
May | 23.45 | 11.83 |
June | 24.29 | 17.35 |
July | 24.35 | 20.52 |
August | 24.30 | 18.54 |
September | 23.99 | 14.70 |
October | 22.32 | 6.26 |
November | 21.78 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.83 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.35 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F4 SE APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.85 | -4.7 |
February | 22.06 | -3.7 |
March | 22.48 | 2.15 |
April | 23.20 | 6.19 |
May | 23.80 | 11.83 |
June | 24.33 | 17.35 |
July | 24.37 | 20.52 |
August | 24.36 | 18.54 |
September | 24.25 | 14.70 |
October | 23.35 | 6.26 |
November | 22.25 | 1.12 |
December | 21.87 | -5.0 |
Annual Sum or Average | 23.19 | 7.16 |
Minimum of Months | 21.85 | -5.0 |
Maximum of Months | 24.37 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F4 NE APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.78 | 2.15 |
April | 22.34 | 6.19 |
May | 23.38 | 11.83 |
June | 24.26 | 17.35 |
July | 24.36 | 20.52 |
August | 24.30 | 18.54 |
September | 23.90 | 14.70 |
October | 22.18 | 6.26 |
November | 21.75 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.78 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.36 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F4 N1 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.77 | 2.15 |
April | 22.24 | 6.19 |
May | 23.30 | 11.83 |
June | 24.23 | 17.35 |
July | 24.33 | 20.52 |
August | 24.27 | 18.54 |
September | 23.96 | 14.70 |
October | 22.22 | 6.26 |
November | 21.78 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.77 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.33 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F4 N2 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.77 | 2.15 |
April | 22.23 | 6.19 |
May | 23.30 | 11.83 |
June | 24.23 | 17.35 |
July | 24.33 | 20.52 |
August | 24.27 | 18.54 |
September | 23.95 | 14.70 |
October | 22.21 | 6.26 |
November | 21.78 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.77 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.33 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F4 S1 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.99 | -4.7 |
February | 22.31 | -3.7 |
March | 22.74 | 2.15 |
April | 23.38 | 6.19 |
May | 23.88 | 11.83 |
June | 24.30 | 17.35 |
July | 24.35 | 20.52 |
August | 24.35 | 18.54 |
September | 24.34 | 14.70 |
October | 23.64 | 6.26 |
November | 22.60 | 1.12 |
December | 22.04 | -5.0 |
Annual Sum or Average | 23.33 | 7.16 |
Minimum of Months | 21.99 | -5.0 |
Maximum of Months | 24.35 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F4 S2 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.00 | -4.7 |
February | 22.31 | -3.7 |
March | 22.74 | 2.15 |
April | 23.38 | 6.19 |
May | 23.88 | 11.83 |
June | 24.30 | 17.35 |
July | 24.35 | 20.52 |
August | 24.35 | 18.54 |
September | 24.34 | 14.70 |
October | 23.63 | 6.26 |
November | 22.60 | 1.12 |
December | 22.04 | -5.0 |
Annual Sum or Average | 23.33 | 7.16 |
Minimum of Months | 22.00 | -5.0 |
Maximum of Months | 24.35 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F4 CORRIDOR
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.94 | -4.7 |
February | 22.34 | -3.7 |
March | 22.97 | 2.15 |
April | 23.88 | 6.19 |
May | 25.06 | 11.83 |
June | 26.20 | 17.35 |
July | 26.52 | 20.52 |
August | 26.30 | 18.54 |
September | 25.81 | 14.70 |
October | 23.94 | 6.26 |
November | 22.63 | 1.12 |
December | 21.87 | -5.0 |
Annual Sum or Average | 24.13 | 7.16 |
Minimum of Months | 21.87 | -5.0 |
Maximum of Months | 26.52 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.86 | -4.7 |
February | 22.09 | -3.7 |
March | 22.51 | 2.15 |
April | 23.15 | 6.19 |
May | 23.76 | 11.83 |
June | 24.32 | 17.35 |
July | 24.35 | 20.52 |
August | 24.35 | 18.54 |
September | 24.27 | 14.70 |
October | 23.37 | 6.26 |
November | 22.28 | 1.12 |
December | 21.88 | -5.0 |
Annual Sum or Average | 23.19 | 7.16 |
Minimum of Months | 21.86 | -5.0 |
Maximum of Months | 24.35 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.71 | -3.7 |
March | 21.83 | 2.15 |
April | 22.42 | 6.19 |
May | 23.42 | 11.83 |
June | 24.28 | 17.35 |
July | 24.34 | 20.52 |
August | 24.30 | 18.54 |
September | 23.98 | 14.70 |
October | 22.33 | 6.26 |
November | 21.78 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.82 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.34 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.85 | -4.7 |
February | 22.06 | -3.7 |
March | 22.46 | 2.15 |
April | 23.17 | 6.19 |
May | 23.76 | 11.83 |
June | 24.32 | 17.35 |
July | 24.37 | 20.52 |
August | 24.36 | 18.54 |
September | 24.25 | 14.70 |
October | 23.34 | 6.26 |
November | 22.24 | 1.12 |
December | 21.87 | -5.0 |
Annual Sum or Average | 23.18 | 7.16 |
Minimum of Months | 21.85 | -5.0 |
Maximum of Months | 24.37 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.78 | 2.15 |
April | 22.33 | 6.19 |
May | 23.35 | 11.83 |
June | 24.25 | 17.35 |
July | 24.36 | 20.52 |
August | 24.29 | 18.54 |
September | 23.89 | 14.70 |
October | 22.19 | 6.26 |
November | 21.75 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.78 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.36 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.78 | 2.15 |
April | 22.25 | 6.19 |
May | 23.29 | 11.83 |
June | 24.23 | 17.35 |
July | 24.32 | 20.52 |
August | 24.27 | 18.54 |
September | 23.96 | 14.70 |
October | 22.25 | 6.26 |
November | 21.78 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.78 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.32 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.78 | 2.15 |
April | 22.24 | 6.19 |
May | 23.29 | 11.83 |
June | 24.23 | 17.35 |
July | 24.33 | 20.52 |
August | 24.27 | 18.54 |
September | 23.95 | 14.70 |
October | 22.24 | 6.26 |
November | 21.78 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.77 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.33 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.00 | -4.7 |
February | 22.32 | -3.7 |
March | 22.74 | 2.15 |
April | 23.37 | 6.19 |
May | 23.86 | 11.83 |
June | 24.30 | 17.35 |
July | 24.34 | 20.52 |
August | 24.35 | 18.54 |
September | 24.34 | 14.70 |
October | 23.65 | 6.26 |
November | 22.60 | 1.12 |
December | 22.04 | -5.0 |
Annual Sum or Average | 23.33 | 7.16 |
Minimum of Months | 22.00 | -5.0 |
Maximum of Months | 24.35 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.00 | -4.7 |
February | 22.32 | -3.7 |
March | 22.73 | 2.15 |
April | 23.37 | 6.19 |
May | 23.86 | 11.83 |
June | 24.30 | 17.35 |
July | 24.35 | 20.52 |
August | 24.35 | 18.54 |
September | 24.34 | 14.70 |
October | 23.65 | 6.26 |
November | 22.60 | 1.12 |
December | 22.04 | -5.0 |
Annual Sum or Average | 23.33 | 7.16 |
Minimum of Months | 22.00 | -5.0 |
Maximum of Months | 24.35 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.54 | -4.7 |
February | 22.93 | -3.7 |
March | 23.53 | 2.15 |
April | 24.42 | 6.19 |
May | 25.59 | 11.83 |
June | 26.74 | 17.35 |
July | 27.06 | 20.52 |
August | 26.84 | 18.54 |
September | 26.36 | 14.70 |
October | 24.51 | 6.26 |
November | 23.21 | 1.12 |
December | 22.46 | -5.0 |
Annual Sum or Average | 24.69 | 7.16 |
Minimum of Months | 22.46 | -5.0 |
Maximum of Months | 27.06 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F6 SW APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.84 | -4.7 |
February | 22.05 | -3.7 |
March | 22.44 | 2.15 |
April | 23.06 | 6.19 |
May | 23.66 | 11.83 |
June | 24.30 | 17.35 |
July | 24.35 | 20.52 |
August | 24.34 | 18.54 |
September | 24.24 | 14.70 |
October | 23.31 | 6.26 |
November | 22.22 | 1.12 |
December | 21.87 | -5.0 |
Annual Sum or Average | 23.14 | 7.16 |
Minimum of Months | 21.84 | -5.0 |
Maximum of Months | 24.35 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F6 NW APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.71 | -3.7 |
March | 21.81 | 2.15 |
April | 22.34 | 6.19 |
May | 23.31 | 11.83 |
June | 24.25 | 17.35 |
July | 24.33 | 20.52 |
August | 24.27 | 18.54 |
September | 23.92 | 14.70 |
October | 22.25 | 6.26 |
November | 21.77 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.79 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.33 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F6 SE APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.83 | -4.7 |
February | 22.02 | -3.7 |
March | 22.40 | 2.15 |
April | 23.07 | 6.19 |
May | 23.67 | 11.83 |
June | 24.30 | 17.35 |
July | 24.37 | 20.52 |
August | 24.34 | 18.54 |
September | 24.21 | 14.70 |
October | 23.29 | 6.26 |
November | 22.18 | 1.12 |
December | 21.86 | -5.0 |
Annual Sum or Average | 23.13 | 7.16 |
Minimum of Months | 21.83 | -5.0 |
Maximum of Months | 24.37 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F6 NE APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.77 | 2.15 |
April | 22.25 | 6.19 |
May | 23.25 | 11.83 |
June | 24.21 | 17.35 |
July | 24.35 | 20.52 |
August | 24.27 | 18.54 |
September | 23.82 | 14.70 |
October | 22.12 | 6.26 |
November | 21.74 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.75 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.35 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F6 N1 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.76 | 2.15 |
April | 22.17 | 6.19 |
May | 23.18 | 11.83 |
June | 24.19 | 17.35 |
July | 24.31 | 20.52 |
August | 24.24 | 18.54 |
September | 23.89 | 14.70 |
October | 22.17 | 6.26 |
November | 21.77 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.74 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.31 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F6 N2 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.76 | 2.15 |
April | 22.16 | 6.19 |
May | 23.17 | 11.83 |
June | 24.19 | 17.35 |
July | 24.31 | 20.52 |
August | 24.25 | 18.54 |
September | 23.88 | 14.70 |
October | 22.16 | 6.26 |
November | 21.77 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.73 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.31 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F6 S1 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.97 | -4.7 |
February | 22.26 | -3.7 |
March | 22.65 | 2.15 |
April | 23.26 | 6.19 |
May | 23.76 | 11.83 |
June | 24.28 | 17.35 |
July | 24.34 | 20.52 |
August | 24.34 | 18.54 |
September | 24.32 | 14.70 |
October | 23.58 | 6.26 |
November | 22.53 | 1.12 |
December | 22.01 | -5.0 |
Annual Sum or Average | 23.28 | 7.16 |
Minimum of Months | 21.97 | -5.0 |
Maximum of Months | 24.34 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F6 S2 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.97 | -4.7 |
February | 22.26 | -3.7 |
March | 22.65 | 2.15 |
April | 23.27 | 6.19 |
May | 23.76 | 11.83 |
June | 24.28 | 17.35 |
July | 24.34 | 20.52 |
August | 24.34 | 18.54 |
September | 24.32 | 14.70 |
October | 23.58 | 6.26 |
November | 22.53 | 1.12 |
December | 22.01 | -5.0 |
Annual Sum or Average | 23.28 | 7.16 |
Minimum of Months | 21.97 | -5.0 |
Maximum of Months | 24.34 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F6 CORRIDOR
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.91 | -4.7 |
February | 22.30 | -3.7 |
March | 22.89 | 2.15 |
April | 23.77 | 6.19 |
May | 24.93 | 11.83 |
June | 26.15 | 17.35 |
July | 26.50 | 20.52 |
August | 26.27 | 18.54 |
September | 25.75 | 14.70 |
October | 23.88 | 6.26 |
November | 22.57 | 1.12 |
December | 21.83 | -5.0 |
Annual Sum or Average | 24.07 | 7.16 |
Minimum of Months | 21.83 | -5.0 |
Maximum of Months | 26.50 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F7 SW APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.83 | -4.7 |
February | 22.03 | -3.7 |
March | 22.39 | 2.15 |
April | 22.98 | 6.19 |
May | 23.58 | 11.83 |
June | 24.28 | 17.35 |
July | 24.34 | 20.52 |
August | 24.33 | 18.54 |
September | 24.21 | 14.70 |
October | 23.26 | 6.26 |
November | 22.18 | 1.12 |
December | 21.85 | -5.0 |
Annual Sum or Average | 23.11 | 7.16 |
Minimum of Months | 21.83 | -5.0 |
Maximum of Months | 24.34 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F7 NW APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.71 | -3.7 |
March | 21.80 | 2.15 |
April | 22.28 | 6.19 |
May | 23.22 | 11.83 |
June | 24.23 | 17.35 |
July | 24.33 | 20.52 |
August | 24.26 | 18.54 |
September | 23.86 | 14.70 |
October | 22.19 | 6.26 |
November | 21.76 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.76 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.33 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F7 SE APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.82 | -4.7 |
February | 22.00 | -3.7 |
March | 22.35 | 2.15 |
April | 23.00 | 6.19 |
May | 23.60 | 11.83 |
June | 24.28 | 17.35 |
July | 24.36 | 20.52 |
August | 24.33 | 18.54 |
September | 24.19 | 14.70 |
October | 23.24 | 6.26 |
November | 22.14 | 1.12 |
December | 21.85 | -5.0 |
Annual Sum or Average | 23.10 | 7.16 |
Minimum of Months | 21.82 | -5.0 |
Maximum of Months | 24.36 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F7 NE APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.76 | 2.15 |
April | 22.20 | 6.19 |
May | 23.17 | 11.83 |
June | 24.18 | 17.35 |
July | 24.34 | 20.52 |
August | 24.25 | 18.54 |
September | 23.76 | 14.70 |
October | 22.07 | 6.26 |
November | 21.73 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.72 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.34 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F7 N1 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.75 | 2.15 |
April | 22.12 | 6.19 |
May | 23.09 | 11.83 |
June | 24.16 | 17.35 |
July | 24.30 | 20.52 |
August | 24.23 | 18.54 |
September | 23.83 | 14.70 |
October | 22.11 | 6.26 |
November | 21.76 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.71 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.30 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F7 N2 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.75 | 2.15 |
April | 22.11 | 6.19 |
May | 23.09 | 11.83 |
June | 24.16 | 17.35 |
July | 24.31 | 20.52 |
August | 24.23 | 18.54 |
September | 23.82 | 14.70 |
October | 22.10 | 6.26 |
November | 21.76 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.71 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.31 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F7 S1 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.95 | -4.7 |
February | 22.21 | -3.7 |
March | 22.59 | 2.15 |
April | 23.18 | 6.19 |
May | 23.67 | 11.83 |
June | 24.26 | 17.35 |
July | 24.33 | 20.52 |
August | 24.33 | 18.54 |
September | 24.30 | 14.70 |
October | 23.53 | 6.26 |
November | 22.47 | 1.12 |
December | 21.98 | -5.0 |
Annual Sum or Average | 23.24 | 7.16 |
Minimum of Months | 21.95 | -5.0 |
Maximum of Months | 24.33 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F7 S2 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.95 | -4.7 |
February | 22.21 | -3.7 |
March | 22.58 | 2.15 |
April | 23.18 | 6.19 |
May | 23.68 | 11.83 |
June | 24.26 | 17.35 |
July | 24.33 | 20.52 |
August | 24.33 | 18.54 |
September | 24.30 | 14.70 |
October | 23.53 | 6.26 |
November | 22.47 | 1.12 |
December | 21.98 | -5.0 |
Annual Sum or Average | 23.24 | 7.16 |
Minimum of Months | 21.95 | -5.0 |
Maximum of Months | 24.33 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F7 CORRIDOR
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.78 | -4.7 |
February | 22.16 | -3.7 |
March | 22.74 | 2.15 |
April | 23.60 | 6.19 |
May | 24.75 | 11.83 |
June | 26.04 | 17.35 |
July | 26.41 | 20.52 |
August | 26.17 | 18.54 |
September | 25.62 | 14.70 |
October | 23.72 | 6.26 |
November | 22.42 | 1.12 |
December | 21.69 | -5.0 |
Annual Sum or Average | 23.93 | 7.16 |
Minimum of Months | 21.69 | -5.0 |
Maximum of Months | 26.41 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F8 SW APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.82 | -4.7 |
February | 22.01 | -3.7 |
March | 22.34 | 2.15 |
April | 22.92 | 6.19 |
May | 23.51 | 11.83 |
June | 24.26 | 17.35 |
July | 24.34 | 20.52 |
August | 24.32 | 18.54 |
September | 24.18 | 14.70 |
October | 23.21 | 6.26 |
November | 22.14 | 1.12 |
December | 21.84 | -5.0 |
Annual Sum or Average | 23.08 | 7.16 |
Minimum of Months | 21.82 | -5.0 |
Maximum of Months | 24.34 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F8 NW APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.71 | -3.7 |
March | 21.79 | 2.15 |
April | 22.24 | 6.19 |
May | 23.15 | 11.83 |
June | 24.20 | 17.35 |
July | 24.32 | 20.52 |
August | 24.24 | 18.54 |
September | 23.81 | 14.70 |
October | 22.15 | 6.26 |
November | 21.75 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.73 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.32 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F8 SE APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.81 | -4.7 |
February | 21.98 | -3.7 |
March | 22.31 | 2.15 |
April | 22.94 | 6.19 |
May | 23.53 | 11.83 |
June | 24.26 | 17.35 |
July | 24.36 | 20.52 |
August | 24.33 | 18.54 |
September | 24.16 | 14.70 |
October | 23.19 | 6.26 |
November | 22.10 | 1.12 |
December | 21.84 | -5.0 |
Annual Sum or Average | 23.07 | 7.16 |
Minimum of Months | 21.81 | -5.0 |
Maximum of Months | 24.36 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F8 NE APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.75 | 2.15 |
April | 22.16 | 6.19 |
May | 23.11 | 11.83 |
June | 24.15 | 17.35 |
July | 24.34 | 20.52 |
August | 24.23 | 18.54 |
September | 23.71 | 14.70 |
October | 22.04 | 6.26 |
November | 21.73 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.70 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.34 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F8 N1 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.75 | 2.15 |
April | 22.08 | 6.19 |
May | 23.02 | 11.83 |
June | 24.13 | 17.35 |
July | 24.30 | 20.52 |
August | 24.21 | 18.54 |
September | 23.77 | 14.70 |
October | 22.06 | 6.26 |
November | 21.75 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.69 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.30 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F8 N2 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.75 | 2.15 |
April | 22.08 | 6.19 |
May | 23.02 | 11.83 |
June | 24.13 | 17.35 |
July | 24.30 | 20.52 |
August | 24.21 | 18.54 |
September | 23.76 | 14.70 |
October | 22.05 | 6.26 |
November | 21.75 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.68 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.30 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F8 S1 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.92 | -4.7 |
February | 22.17 | -3.7 |
March | 22.53 | 2.15 |
April | 23.10 | 6.19 |
May | 23.59 | 11.83 |
June | 24.24 | 17.35 |
July | 24.32 | 20.52 |
August | 24.32 | 18.54 |
September | 24.28 | 14.70 |
October | 23.47 | 6.26 |
November | 22.41 | 1.12 |
December | 21.96 | -5.0 |
Annual Sum or Average | 23.20 | 7.16 |
Minimum of Months | 21.92 | -5.0 |
Maximum of Months | 24.32 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F8 S2 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.92 | -4.7 |
February | 22.17 | -3.7 |
March | 22.52 | 2.15 |
April | 23.10 | 6.19 |
May | 23.60 | 11.83 |
June | 24.24 | 17.35 |
July | 24.33 | 20.52 |
August | 24.32 | 18.54 |
September | 24.28 | 14.70 |
October | 23.47 | 6.26 |
November | 22.41 | 1.12 |
December | 21.96 | -5.0 |
Annual Sum or Average | 23.20 | 7.16 |
Minimum of Months | 21.92 | -5.0 |
Maximum of Months | 24.33 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F8 CORRIDOR
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 22.07 | -3.7 |
March | 22.64 | 2.15 |
April | 23.49 | 6.19 |
May | 24.64 | 11.83 |
June | 25.99 | 17.35 |
July | 26.39 | 20.52 |
August | 26.14 | 18.54 |
September | 25.55 | 14.70 |
October | 23.62 | 6.26 |
November | 22.32 | 1.12 |
December | 21.60 | -5.0 |
Annual Sum or Average | 23.86 | 7.16 |
Minimum of Months | 21.60 | -5.0 |
Maximum of Months | 26.39 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F9 SW APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.80 | -4.7 |
February | 21.97 | -3.7 |
March | 22.28 | 2.15 |
April | 22.85 | 6.19 |
May | 23.44 | 11.83 |
June | 24.24 | 17.35 |
July | 24.33 | 20.52 |
August | 24.30 | 18.54 |
September | 24.13 | 14.70 |
October | 23.10 | 6.26 |
November | 22.09 | 1.12 |
December | 21.82 | -5.0 |
Annual Sum or Average | 23.04 | 7.16 |
Minimum of Months | 21.80 | -5.0 |
Maximum of Months | 24.33 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F9 NW APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.71 | -3.7 |
March | 21.78 | 2.15 |
April | 22.21 | 6.19 |
May | 23.09 | 11.83 |
June | 24.17 | 17.35 |
July | 24.31 | 20.52 |
August | 24.22 | 18.54 |
September | 23.73 | 14.70 |
October | 22.11 | 6.26 |
November | 21.74 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.71 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.31 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F9 SE APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.80 | -4.7 |
February | 21.94 | -3.7 |
March | 22.25 | 2.15 |
April | 22.86 | 6.19 |
May | 23.47 | 11.83 |
June | 24.24 | 17.35 |
July | 24.35 | 20.52 |
August | 24.31 | 18.54 |
September | 24.11 | 14.70 |
October | 23.09 | 6.26 |
November | 22.05 | 1.12 |
December | 21.82 | -5.0 |
Annual Sum or Average | 23.03 | 7.16 |
Minimum of Months | 21.80 | -5.0 |
Maximum of Months | 24.35 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F9 NE APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.74 | 2.15 |
April | 22.13 | 6.19 |
May | 23.05 | 11.83 |
June | 24.11 | 17.35 |
July | 24.33 | 20.52 |
August | 24.21 | 18.54 |
September | 23.63 | 14.70 |
October | 21.99 | 6.26 |
November | 21.72 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.67 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.33 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F9 N1 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.74 | 2.15 |
April | 22.06 | 6.19 |
May | 22.97 | 11.83 |
June | 24.10 | 17.35 |
July | 24.29 | 20.52 |
August | 24.19 | 18.54 |
September | 23.68 | 14.70 |
October | 22.01 | 6.26 |
November | 21.74 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.66 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.29 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F9 N2 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.74 | 2.15 |
April | 22.06 | 6.19 |
May | 22.97 | 11.83 |
June | 24.09 | 17.35 |
July | 24.29 | 20.52 |
August | 24.19 | 18.54 |
September | 23.67 | 14.70 |
October | 22.01 | 6.26 |
November | 21.74 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.66 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.29 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F9 S1 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.89 | -4.7 |
February | 22.09 | -3.7 |
March | 22.43 | 2.15 |
April | 23.00 | 6.19 |
May | 23.51 | 11.83 |
June | 24.22 | 17.35 |
July | 24.32 | 20.52 |
August | 24.31 | 18.54 |
September | 24.23 | 14.70 |
October | 23.35 | 6.26 |
November | 22.31 | 1.12 |
December | 21.92 | -5.0 |
Annual Sum or Average | 23.14 | 7.16 |
Minimum of Months | 21.89 | -5.0 |
Maximum of Months | 24.32 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F9 S2 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.89 | -4.7 |
February | 22.09 | -3.7 |
March | 22.43 | 2.15 |
April | 23.01 | 6.19 |
May | 23.52 | 11.83 |
June | 24.22 | 17.35 |
July | 24.32 | 20.52 |
August | 24.31 | 18.54 |
September | 24.23 | 14.70 |
October | 23.35 | 6.26 |
November | 22.31 | 1.12 |
December | 21.92 | -5.0 |
Annual Sum or Average | 23.14 | 7.16 |
Minimum of Months | 21.89 | -5.0 |
Maximum of Months | 24.32 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: F9 CORRIDOR
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.49 | -4.7 |
February | 21.87 | -3.7 |
March | 22.47 | 2.15 |
April | 23.37 | 6.19 |
May | 24.56 | 11.83 |
June | 25.98 | 17.35 |
July | 26.44 | 20.52 |
August | 26.14 | 18.54 |
September | 25.46 | 14.70 |
October | 23.43 | 6.26 |
November | 22.13 | 1.12 |
December | 21.39 | -5.0 |
Annual Sum or Average | 23.74 | 7.16 |
Minimum of Months | 21.39 | -5.0 |
Maximum of Months | 26.44 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.86 | -4.7 |
February | 22.00 | -3.7 |
March | 22.23 | 2.15 |
April | 22.71 | 6.19 |
May | 23.23 | 11.83 |
June | 24.07 | 17.35 |
July | 24.25 | 20.52 |
August | 24.18 | 18.54 |
September | 23.85 | 14.70 |
October | 22.73 | 6.26 |
November | 22.10 | 1.12 |
December | 21.85 | -5.0 |
Annual Sum or Average | 22.93 | 7.16 |
Minimum of Months | 21.85 | -5.0 |
Maximum of Months | 24.25 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.73 | -3.7 |
March | 21.84 | 2.15 |
April | 22.30 | 6.19 |
May | 22.99 | 11.83 |
June | 23.99 | 17.35 |
July | 24.23 | 20.52 |
August | 24.06 | 18.54 |
September | 23.52 | 14.70 |
October | 22.18 | 6.26 |
November | 21.77 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.67 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.23 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.85 | -4.7 |
February | 21.98 | -3.7 |
March | 22.19 | 2.15 |
April | 22.74 | 6.19 |
May | 23.24 | 11.83 |
June | 24.05 | 17.35 |
July | 24.28 | 20.52 |
August | 24.18 | 18.54 |
September | 23.84 | 14.70 |
October | 22.73 | 6.26 |
November | 22.07 | 1.12 |
December | 21.84 | -5.0 |
Annual Sum or Average | 22.92 | 7.16 |
Minimum of Months | 21.84 | -5.0 |
Maximum of Months | 24.28 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.78 | 2.15 |
April | 22.22 | 6.19 |
May | 22.98 | 11.83 |
June | 23.90 | 17.35 |
July | 24.22 | 20.52 |
August | 24.01 | 18.54 |
September | 23.45 | 14.70 |
October | 22.08 | 6.26 |
November | 21.74 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.63 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.22 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.78 | 2.15 |
April | 22.16 | 6.19 |
May | 22.89 | 11.83 |
June | 23.93 | 17.35 |
July | 24.21 | 20.52 |
August | 24.03 | 18.54 |
September | 23.47 | 14.70 |
October | 22.05 | 6.26 |
November | 21.75 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.62 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.21 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.77 | 2.15 |
April | 22.16 | 6.19 |
May | 22.90 | 11.83 |
June | 23.93 | 17.35 |
July | 24.21 | 20.52 |
August | 24.03 | 18.54 |
September | 23.46 | 14.70 |
October | 22.05 | 6.26 |
November | 21.75 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.62 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.21 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.91 | -4.7 |
February | 22.06 | -3.7 |
March | 22.31 | 2.15 |
April | 22.82 | 6.19 |
May | 23.30 | 11.83 |
June | 24.09 | 17.35 |
July | 24.27 | 20.52 |
August | 24.22 | 18.54 |
September | 23.98 | 14.70 |
October | 22.90 | 6.26 |
November | 22.21 | 1.12 |
December | 21.92 | -5.0 |
Annual Sum or Average | 23.00 | 7.16 |
Minimum of Months | 21.91 | -5.0 |
Maximum of Months | 24.27 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.91 | -4.7 |
February | 22.06 | -3.7 |
March | 22.31 | 2.15 |
April | 22.82 | 6.19 |
May | 23.30 | 11.83 |
June | 24.10 | 17.35 |
July | 24.27 | 20.52 |
August | 24.22 | 18.54 |
September | 23.98 | 14.70 |
October | 22.90 | 6.26 |
November | 22.21 | 1.12 |
December | 21.92 | -5.0 |
Annual Sum or Average | 23.00 | 7.16 |
Minimum of Months | 21.91 | -5.0 |
Maximum of Months | 24.27 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2015-09-09 19:11:13
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.12 | -4.7 |
February | 21.62 | -3.7 |
March | 22.44 | 2.15 |
April | 23.57 | 6.19 |
May | 24.94 | 11.83 |
June | 26.55 | 17.35 |
July | 27.16 | 20.52 |
August | 26.70 | 18.54 |
September | 25.75 | 14.70 |
October | 23.38 | 6.26 |
November | 21.95 | 1.12 |
December | 21.03 | -5.0 |
Annual Sum or Average | 23.86 | 7.16 |
Minimum of Months | 21.03 | -5.0 |
Maximum of Months | 27.16 | 20.52 |
Report: COMPONENTS OF PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2015-09-09 19:11:13
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W] | |
January | 0.264326E+12 | 162283.531 | 14-JAN-17:15 | 11327.174 | 57042.023 | 23378.631 | 56369.595 | 0.000 | 10364.000 | 1814.465 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
February | 0.228919E+12 | 159556.501 | 22-FEB-20:00 | 14401.373 | 49889.926 | 23378.631 | 58066.802 | 0.000 | 10364.000 | 1814.465 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
March | 0.235233E+12 | 128082.235 | 10-MAR-18:00 | 13120.457 | 57042.023 | 23378.631 | 20374.650 | 0.000 | 10364.000 | 1814.465 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
April | 0.214884E+12 | 131922.843 | 12-APR-19:00 | 14401.373 | 49889.926 | 23378.631 | 30433.144 | 0.000 | 10364.000 | 1814.465 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
May | 0.219145E+12 | 157317.523 | 23-MAY-17:00 | 13120.457 | 57042.023 | 23378.631 | 0.000 | 58229.291 | 0.000 | 1814.465 | 1744.647 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
June | 0.240451E+12 | 161397.825 | 30-JUN-16:15 | 11327.174 | 57142.088 | 23378.631 | 0.000 | 63679.565 | 0.000 | 1814.465 | 2060.705 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
July | 0.274492E+12 | 162363.160 | 21-JUL-17:15 | 13120.457 | 57042.023 | 23378.631 | 0.000 | 63002.330 | 0.000 | 1814.465 | 2017.442 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.261697E+12 | 163289.670 | 10-AUG-17:15 | 13120.457 | 57042.023 | 23378.631 | 0.000 | 63985.568 | 0.000 | 1814.465 | 1960.714 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.237232E+12 | 161167.899 | 15-SEP-17:15 | 13120.457 | 57042.023 | 23378.631 | 0.000 | 61919.343 | 0.000 | 1814.465 | 1905.169 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
October | 0.224506E+12 | 125190.875 | 08-OCT-17:00 | 13120.457 | 57042.023 | 23378.631 | 0.000 | 16884.838 | 10364.000 | 1814.465 | 598.453 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
November | 0.233615E+12 | 141580.248 | 30-NOV-20:00 | 14401.373 | 49889.926 | 23378.631 | 40090.549 | 0.000 | 10364.000 | 1814.465 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
December | 0.270473E+12 | 170607.635 | 25-DEC-17:15 | 11327.174 | 57042.023 | 23378.631 | 64693.699 | 0.000 | 10364.000 | 1814.465 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.290497E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||||
Minimum of Months | 0.214884E+12 | 125190.875 | 11327.174 | 49889.926 | 23378.631 | 0.000 | 0.000 | 0.000 | 1814.465 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.274492E+12 | 170607.635 | 14401.373 | 57142.088 | 23378.631 | 64693.699 | 63985.568 | 10364.000 | 1814.465 | 2060.705 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: COMPONENTS OF PEAK GAS DEMAND
For: Meter
Timestamp: 2015-09-09 19:11:13
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC [Invalid/Undefined] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT {AT MAX/MIN} [W] | WATERSYSTEMS:GAS {AT MAX/MIN} [W] | WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.324096E+12 | 308227.489 | 15-JAN-06:00 | 0.000 | 0.000 | 0.000 | 308227.489 | 81748.096 | 81748.096 | 226479.393 |
February | 0.257280E+12 | 288647.226 | 23-FEB-08:00 | 0.000 | 0.000 | 0.000 | 288647.226 | 83585.827 | 83585.827 | 205061.398 |
March | 0.209302E+12 | 232107.215 | 11-MAR-08:00 | 0.000 | 0.000 | 0.000 | 232107.215 | 83285.520 | 83285.520 | 148821.695 |
April | 0.150262E+12 | 271079.550 | 13-APR-06:30 | 0.000 | 0.000 | 0.000 | 271079.550 | 83236.973 | 83236.973 | 187842.577 |
May | 0.111198E+12 | 118857.882 | 06-MAY-07:30 | 0.000 | 0.000 | 0.000 | 118857.882 | 80399.552 | 80399.552 | 38458.329 |
June | 0.979482E+11 | 79810.438 | 01-JUN-06:00 | 0.000 | 0.000 | 0.000 | 79810.438 | 79810.438 | 79810.438 | 0.000 |
July | 0.965580E+11 | 77834.827 | 01-JUL-06:00 | 0.000 | 0.000 | 0.000 | 77834.827 | 77834.827 | 77834.827 | 0.000 |
August | 0.944865E+11 | 76585.181 | 02-AUG-06:00 | 0.000 | 0.000 | 0.000 | 76585.181 | 76585.181 | 76585.181 | 0.000 |
September | 0.925258E+11 | 77344.039 | 30-SEP-06:00 | 0.000 | 0.000 | 0.000 | 77344.039 | 77344.039 | 77344.039 | 0.000 |
October | 0.120494E+12 | 155786.331 | 05-OCT-06:15 | 0.000 | 0.000 | 0.000 | 155786.331 | 76493.973 | 76493.973 | 79292.358 |
November | 0.209186E+12 | 230822.592 | 30-NOV-20:30 | 0.000 | 0.000 | 0.000 | 230822.592 | 72585.101 | 72585.101 | 158237.492 |
December | 0.340708E+12 | 314234.364 | 25-DEC-08:00 | 0.000 | 0.000 | 0.000 | 314234.364 | 81610.683 | 81610.683 | 232623.681 |
Annual Sum or Average | 0.210404E+13 | 0.000 | 0.000 | 0.000 | ||||||
Minimum of Months | 0.925258E+11 | 76585.181 | 0.000 | 0.000 | 0.000 | 76585.181 | 72585.101 | 72585.101 | 0.000 | |
Maximum of Months | 0.340708E+12 | 314234.364 | 0.000 | 0.000 | 0.000 | 314234.364 | 83585.827 | 83585.827 | 232623.681 |