Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:59

Tabular Output Report in Format: HTML

Building: High-Rise Apartment

Environment: Boise Air Terminal Uo ID USA TMY3 WMO#=726810

Simulation Timestamp: 2015-09-09 19:00:31


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 4679.50 597.14 662.83
Net Site Energy 4679.50 597.14 662.83
Total Source Energy 11258.96 1436.74 1594.78
Net Source Energy 11258.96 1436.74 1594.78


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 7836.48
Net Conditioned Building Area 7059.89
Unconditioned Building Area 776.58


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 159.58 544.55 0.00 0.00 0.00 0.00
Cooling 353.52 0.00 0.00 0.00 0.00 0.00
Interior Lighting 296.56 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 162.61 0.00 0.00 0.00 0.00 0.00
Interior Equipment 1137.32 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 750.51 0.00 0.00 0.00 0.00 0.00
Pumps 61.16 0.00 0.00 0.00 0.00 0.00
Heat Rejection 12.51 0.00 0.00 0.00 0.00 1290.70
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 1165.01 0.00 0.00 0.00 4778.51
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 2969.94 1709.56 0.00 0.00 0.00 6069.22
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating Boiler 0.00 544.55 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
  Other 159.58 0.00 0.00 0.00 0.00 0.00
Cooling General 353.52 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 242.55 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 54.01 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 162.61 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 1137.32 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 750.51 0.00 0.00 0.00 0.00 0.00
Pumps General 61.16 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 12.51 0.00 0.00 0.00 0.00 1290.70
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 1165.01 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 4778.51
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 65.04 0.00 0.00 0.00 0.00 0.00
HVAC 189.42 242.15 0.00 0.00 0.00 0.86
Other 161.10 0.00 0.00 0.00 0.00 0.00
Total 420.68 242.15 0.00 0.00 0.00 0.86


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 58.59 0.00 0.00 0.00 0.00 0.00
HVAC 170.65 218.15 0.00 0.00 0.00 0.77
Other 145.13 0.00 0.00 0.00 0.00 0.00
Total 378.99 218.15 0.00 0.00 0.00 0.77


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 2969.94 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 2969.94 100.00
     
Total On-Site and Utility Electric Sources 2969.94 100.00
Total Electricity End Uses 2969.94 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 6069.22 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 6069.22 100.00
Total Water End Uses 6069.22 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 133.00
Time Setpoint Not Met During Occupied Cooling 179.25
Time Not Comfortable Based on Simple ASHRAE 55-2004 1144.50


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | G CORRIDOR | F2 SW APARTMENT | F2 NW APARTMENT | F2 SE APARTMENT | F2 NE APARTMENT | F2 N1 APARTMENT | F2 N2 APARTMENT | F2 S1 APARTMENT | F2 S2 APARTMENT | F2 CORRIDOR | F3 SW APARTMENT | F3 NW APARTMENT | F3 SE APARTMENT | F3 NE APARTMENT | F3 N1 APARTMENT | F3 N2 APARTMENT | F3 S1 APARTMENT | F3 S2 APARTMENT | F3 CORRIDOR | F4 SW APARTMENT | F4 NW APARTMENT | F4 SE APARTMENT | F4 NE APARTMENT | F4 N1 APARTMENT | F4 N2 APARTMENT | F4 S1 APARTMENT | F4 S2 APARTMENT | F4 CORRIDOR | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | M CORRIDOR | F6 SW APARTMENT | F6 NW APARTMENT | F6 SE APARTMENT | F6 NE APARTMENT | F6 N1 APARTMENT | F6 N2 APARTMENT | F6 S1 APARTMENT | F6 S2 APARTMENT | F6 CORRIDOR | F7 SW APARTMENT | F7 NW APARTMENT | F7 SE APARTMENT | F7 NE APARTMENT | F7 N1 APARTMENT | F7 N2 APARTMENT | F7 S1 APARTMENT | F7 S2 APARTMENT | F7 CORRIDOR | F8 SW APARTMENT | F8 NW APARTMENT | F8 SE APARTMENT | F8 NE APARTMENT | F8 N1 APARTMENT | F8 N2 APARTMENT | F8 S1 APARTMENT | F8 S2 APARTMENT | F8 CORRIDOR | F9 SW APARTMENT | F9 NW APARTMENT | F9 SE APARTMENT | F9 NE APARTMENT | F9 N1 APARTMENT | F9 N2 APARTMENT | F9 S1 APARTMENT | F9 S2 APARTMENT | F9 CORRIDOR | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR |

COMPONENTS OF PEAK ELECTRICAL DEMAND

| Meter |

COMPONENTS OF PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:59
RunPeriod Boise Air Terminal Uo ID USA TMY3 WMO#=726810
Weather File Boise Air Terminal Uo ID USA TMY3 WMO#=726810
Latitude [deg] 43.62
Longitude [deg] -116.2
Elevation [m] 701.00
Time Zone -7.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3855.02 1411.96 515.55 1411.96 515.55
Window Opening Area [m2] 1150.39 423.59 152.73 423.59 150.48
Window-Wall Ratio [%] 29.84 30.00 29.62 30.00 29.19


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 3752.84 1411.96 464.46 1411.96 464.46
Window Opening Area [m2] 1125.85 423.59 139.34 423.59 139.34
Window-Wall Ratio [%] 30.00 30.00 30.00 30.00 30.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
OFFICE 88.25 Yes Yes 268.96 1.00 58.52 17.56 29.5362 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 4.47 6.7128   0.0000
F2 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F2 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F2 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F3 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F3 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F3 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F4 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F4 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F4 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
M SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
M CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 13.4255   0.0000
F6 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F6 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F6 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F7 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F7 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F7 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F8 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F8 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F8 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
F9 SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
F9 N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
F9 CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   0.0000
T SW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.96 1.00 58.52 17.56 3.6746 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.96 1.00 35.30 10.59 3.6746 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 10.59 3.6746 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 2.23 6.7128   264.3872
Total 7836.48     23884.04   3855.02 1150.39 4.3335 39.48 8.6291
Conditioned Total 7059.89     21517.16   3752.84 1125.85 3.9979 35.57 6.6700
Unconditioned Total 776.58     2366.87   102.18 24.54 7.3840   26.4387
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 31-JUL-17:00 28-DEC-08:15 - - - 21-JUL-17:30
Heating 0.00 187866.75 0.00 0.00 0.00 0.00
Cooling 70644.80 0.00 0.00 0.00 0.00 0.00
Interior Lighting 13120.46 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 57042.02 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 23798.64 0.00 0.00 0.00 0.00 0.00
Pumps 1965.77 0.00 0.00 0.00 0.00 0.00
Heat Rejection 2475.14 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 80520.40 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 171034.84 268387.14 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating Boiler 0.00 187866.75 0.00 0.00 0.00 0.00
  Boiler Parasitic 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 70644.80 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 10541.04 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 2579.42 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 57042.02 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 23798.64 0.00 0.00 0.00 0.00 0.00
Pumps General 1965.77 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 2475.14 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 0.00 80520.40 0.00 0.00 0.00 0.00
  sub cat 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 505.38 590.29 0.00 0.00 0.00
Cooling 1119.59 0.00 0.00 0.00 0.00
Interior Lighting 939.20 0.00 0.00 0.00 0.00
Exterior Lighting 514.98 0.00 0.00 0.00 0.00
Interior Equipment 3601.91 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 2376.88 0.00 0.00 0.00 0.00
Pumps 193.71 0.00 0.00 0.00 0.00
Heat Rejection 39.60 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 1262.87 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 9405.80 1853.16 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 71.58 83.61 0.00 0.00 0.00
Cooling 158.58 0.00 0.00 0.00 0.00
Interior Lighting 133.03 0.00 0.00 0.00 0.00
Exterior Lighting 72.94 0.00 0.00 0.00 0.00
Interior Equipment 510.19 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 336.67 0.00 0.00 0.00 0.00
Pumps 27.44 0.00 0.00 0.00 0.00
Heat Rejection 5.61 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 178.88 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1332.29 262.49 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 71.58 83.61 0.00 0.00 0.00
Cooling 158.58 0.00 0.00 0.00 0.00
Interior Lighting 133.03 0.00 0.00 0.00 0.00
Exterior Lighting 72.94 0.00 0.00 0.00 0.00
Interior Equipment 510.19 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 336.67 0.00 0.00 0.00 0.00
Pumps 27.44 0.00 0.00 0.00 0.00
Heat Rejection 5.61 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 178.88 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1332.29 262.49 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB -16.30 0.00 -16.30 Wetbulb [C] 2.30 120.00
BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 36.70 16.70 17.90 Wetbulb [C] 4.20 330.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 270.00 180.00  
G WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 270.00 180.00  
F2 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F2 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F2 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F2 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F2 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F2 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F2 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F2 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F3 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F3 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F3 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F3 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F3 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F3 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F3 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F3 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F4 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F4 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F4 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F4 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F4 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F4 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F4 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F4 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
M WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
M WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F6 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F6 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F6 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F6 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F6 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F6 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F6 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F6 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F7 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F7 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F7 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F7 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F7 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F7 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F7 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F7 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F8 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F8 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F8 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F8 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F8 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F8 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F8 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F8 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
F9 WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F9 SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
F9 EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F9 SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
F9 NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
F9 SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
F9 WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
F9 EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.30 0.269 0.283 88.25 0.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.30 0.269 0.283 77.66 0.00 0.00  


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL SWA 180.00 90.00 S
GWINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G WWALL SWA 270.00 90.00 W
GWINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL NWA 0.00 90.00 N
GWINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G WWALL NWA 270.00 90.00 W
GWINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL SEA 180.00 90.00 S
GWINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G EWALL SEA 90.00 90.00 E
GWINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL NEA 0.00 90.00 N
GWINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No G EWALL NEA 90.00 90.00 E
GWINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL N1A 0.00 90.00 N
GWINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G NWALL N2A 0.00 90.00 N
GWINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL S1A 180.00 90.00 S
GWINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No G SWALL S2A 180.00 90.00 S
GWINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No G WWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.48_SHGC_0.40 3.36 0.00 0.00 3.36 3.36 2.653 0.426 0.308     No G EWALL C 90.00 90.00 E
F2WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 WWALL SWA 270.00 90.00 W
F2WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL SWA 180.00 90.00 S
F2WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL NWA 0.00 90.00 N
F2WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 WWALL NWA 270.00 90.00 W
F2WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 EWALL SEA 90.00 90.00 E
F2WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL SEA 180.00 90.00 S
F2WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL NEA 0.00 90.00 N
F2WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F2 EWALL NEA 90.00 90.00 E
F2WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL N1A 0.00 90.00 N
F2WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 NWALL N2A 0.00 90.00 N
F2WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL S1A 180.00 90.00 S
F2WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F2 SWALL S2A 180.00 90.00 S
F2WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F2 WWALL C 270.00 90.00 W
F2WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F2 EWALL C 90.00 90.00 E
F3WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 WWALL SWA 270.00 90.00 W
F3WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL SWA 180.00 90.00 S
F3WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL NWA 0.00 90.00 N
F3WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 WWALL NWA 270.00 90.00 W
F3WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 EWALL SEA 90.00 90.00 E
F3WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL SEA 180.00 90.00 S
F3WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL NEA 0.00 90.00 N
F3WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F3 EWALL NEA 90.00 90.00 E
F3WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL N1A 0.00 90.00 N
F3WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 NWALL N2A 0.00 90.00 N
F3WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL S1A 180.00 90.00 S
F3WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F3 SWALL S2A 180.00 90.00 S
F3WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F3 WWALL C 270.00 90.00 W
F3WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F3 EWALL C 90.00 90.00 E
F4WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 WWALL SWA 270.00 90.00 W
F4WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL SWA 180.00 90.00 S
F4WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL NWA 0.00 90.00 N
F4WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 WWALL NWA 270.00 90.00 W
F4WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 EWALL SEA 90.00 90.00 E
F4WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL SEA 180.00 90.00 S
F4WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL NEA 0.00 90.00 N
F4WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F4 EWALL NEA 90.00 90.00 E
F4WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL N1A 0.00 90.00 N
F4WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 NWALL N2A 0.00 90.00 N
F4WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL S1A 180.00 90.00 S
F4WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F4 SWALL S2A 180.00 90.00 S
F4WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F4 WWALL C 270.00 90.00 W
F4WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F4 EWALL C 90.00 90.00 E
MWINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M WWALL SWA 270.00 90.00 W
MWINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL SWA 180.00 90.00 S
MWINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL NWA 0.00 90.00 N
MWINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M WWALL NWA 270.00 90.00 W
MWINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M EWALL SEA 90.00 90.00 E
MWINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL SEA 180.00 90.00 S
MWINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL NEA 0.00 90.00 N
MWINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No M EWALL NEA 90.00 90.00 E
MWINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL N1A 0.00 90.00 N
MWINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M NWALL N2A 0.00 90.00 N
MWINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL S1A 180.00 90.00 S
MWINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No M SWALL S2A 180.00 90.00 S
MWINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No M WWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No M EWALL C 90.00 90.00 E
F6WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 WWALL SWA 270.00 90.00 W
F6WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL SWA 180.00 90.00 S
F6WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL NWA 0.00 90.00 N
F6WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 WWALL NWA 270.00 90.00 W
F6WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 EWALL SEA 90.00 90.00 E
F6WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL SEA 180.00 90.00 S
F6WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL NEA 0.00 90.00 N
F6WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F6 EWALL NEA 90.00 90.00 E
F6WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL N1A 0.00 90.00 N
F6WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 NWALL N2A 0.00 90.00 N
F6WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL S1A 180.00 90.00 S
F6WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F6 SWALL S2A 180.00 90.00 S
F6WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F6 WWALL C 270.00 90.00 W
F6WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F6 EWALL C 90.00 90.00 E
F7WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 WWALL SWA 270.00 90.00 W
F7WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL SWA 180.00 90.00 S
F7WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL NWA 0.00 90.00 N
F7WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 WWALL NWA 270.00 90.00 W
F7WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 EWALL SEA 90.00 90.00 E
F7WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL SEA 180.00 90.00 S
F7WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL NEA 0.00 90.00 N
F7WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F7 EWALL NEA 90.00 90.00 E
F7WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL N1A 0.00 90.00 N
F7WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 NWALL N2A 0.00 90.00 N
F7WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL S1A 180.00 90.00 S
F7WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F7 SWALL S2A 180.00 90.00 S
F7WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F7 WWALL C 270.00 90.00 W
F7WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F7 EWALL C 90.00 90.00 E
F8WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 WWALL SWA 270.00 90.00 W
F8WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL SWA 180.00 90.00 S
F8WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL NWA 0.00 90.00 N
F8WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 WWALL NWA 270.00 90.00 W
F8WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 EWALL SEA 90.00 90.00 E
F8WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL SEA 180.00 90.00 S
F8WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL NEA 0.00 90.00 N
F8WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F8 EWALL NEA 90.00 90.00 E
F8WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL N1A 0.00 90.00 N
F8WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 NWALL N2A 0.00 90.00 N
F8WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL S1A 180.00 90.00 S
F8WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F8 SWALL S2A 180.00 90.00 S
F8WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F8 WWALL C 270.00 90.00 W
F8WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F8 EWALL C 90.00 90.00 E
F9WINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 WWALL SWA 270.00 90.00 W
F9WINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL SWA 180.00 90.00 S
F9WINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL NWA 0.00 90.00 N
F9WINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 WWALL NWA 270.00 90.00 W
F9WINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 EWALL SEA 90.00 90.00 E
F9WINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL SEA 180.00 90.00 S
F9WINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL NEA 0.00 90.00 N
F9WINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No F9 EWALL NEA 90.00 90.00 E
F9WINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL N1A 0.00 90.00 N
F9WINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 NWALL N2A 0.00 90.00 N
F9WINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL S1A 180.00 90.00 S
F9WINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No F9 SWALL S2A 180.00 90.00 S
F9WINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F9 WWALL C 270.00 90.00 W
F9WINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No F9 EWALL C 90.00 90.00 E
TWINDOW2 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T WWALL SWA 270.00 90.00 W
TWINDOW3 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL SWA 180.00 90.00 S
TWINDOW4 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL NWA 0.00 90.00 N
TWINDOW6 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T WWALL NWA 270.00 90.00 W
TWINDOW8 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T EWALL SEA 90.00 90.00 E
TWINDOW1 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL SEA 180.00 90.00 S
TWINDOW5 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL NEA 0.00 90.00 N
TWINDOW7 WINDOW_U_0.48_SHGC_0.40 6.97 0.00 0.00 6.97 6.97 2.653 0.426 0.308     No T EWALL NEA 90.00 90.00 E
TWINDOW9 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL N1A 0.00 90.00 N
TWINDOW10 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T NWALL N2A 0.00 90.00 N
TWINDOW11 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL S1A 180.00 90.00 S
TWINDOW12 WINDOW_U_0.48_SHGC_0.40 10.59 0.00 0.00 10.59 10.59 2.653 0.426 0.308     No T SWALL S2A 180.00 90.00 S
TWINDOW13 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No T WWALL C 270.00 90.00 W
TWINDOW14 WINDOW_U_0.48_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No T EWALL C 90.00 90.00 E
Total or Average           1150.39 2.653 0.426 0.308              
North Total or Average           423.59 2.653 0.426 0.308              
Non-North Total or Average           726.80 2.653 0.426 0.308              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F2WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F2WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F2WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F3WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F3WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F3WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F4WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F4WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F4WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F6WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F6WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F6WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F7WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F7WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F7WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F8WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F8WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F8WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
F9WINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9WINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
F9WINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
F9WINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW2 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW3 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW6 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW8 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW7 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW11 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW12 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW13 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
G SW APARTMENT_LIGHTS_HARDWIRED G SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G NW APARTMENT_LIGHTS_HARDWIRED G NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
OFFICE_LIGHTS_HARDWIRED OFFICE 14.7681 88.25 1303.26 GeneralLights LTG_OFF_SCH 62.05 168.00 61.07 0.0000 Y 14.94
G NE APARTMENT_LIGHTS_HARDWIRED G NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G N1 APARTMENT_LIGHTS_HARDWIRED G N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G N2 APARTMENT_LIGHTS_HARDWIRED G N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G S1 APARTMENT_LIGHTS_HARDWIRED G S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G S2 APARTMENT_LIGHTS_HARDWIRED G S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
G CORRIDOR_LIGHTS_HARDWIRED G CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F2 SW APARTMENT_LIGHTS_HARDWIRED F2 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 NW APARTMENT_LIGHTS_HARDWIRED F2 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 SE APARTMENT_LIGHTS_HARDWIRED F2 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 NE APARTMENT_LIGHTS_HARDWIRED F2 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 N1 APARTMENT_LIGHTS_HARDWIRED F2 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 N2 APARTMENT_LIGHTS_HARDWIRED F2 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 S1 APARTMENT_LIGHTS_HARDWIRED F2 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 S2 APARTMENT_LIGHTS_HARDWIRED F2 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F2 CORRIDOR_LIGHTS_HARDWIRED F2 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F3 SW APARTMENT_LIGHTS_HARDWIRED F3 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 NW APARTMENT_LIGHTS_HARDWIRED F3 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 SE APARTMENT_LIGHTS_HARDWIRED F3 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 NE APARTMENT_LIGHTS_HARDWIRED F3 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 N1 APARTMENT_LIGHTS_HARDWIRED F3 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 N2 APARTMENT_LIGHTS_HARDWIRED F3 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 S1 APARTMENT_LIGHTS_HARDWIRED F3 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 S2 APARTMENT_LIGHTS_HARDWIRED F3 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F3 CORRIDOR_LIGHTS_HARDWIRED F3 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F4 SW APARTMENT_LIGHTS_HARDWIRED F4 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 NW APARTMENT_LIGHTS_HARDWIRED F4 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 SE APARTMENT_LIGHTS_HARDWIRED F4 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 NE APARTMENT_LIGHTS_HARDWIRED F4 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 N1 APARTMENT_LIGHTS_HARDWIRED F4 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 N2 APARTMENT_LIGHTS_HARDWIRED F4 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 S1 APARTMENT_LIGHTS_HARDWIRED F4 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 S2 APARTMENT_LIGHTS_HARDWIRED F4 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F4 CORRIDOR_LIGHTS_HARDWIRED F4 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
M SW APARTMENT_LIGHTS_HARDWIRED M SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M NW APARTMENT_LIGHTS_HARDWIRED M NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M SE APARTMENT_LIGHTS_HARDWIRED M SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M NE APARTMENT_LIGHTS_HARDWIRED M NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M N1 APARTMENT_LIGHTS_HARDWIRED M N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M N2 APARTMENT_LIGHTS_HARDWIRED M N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M S1 APARTMENT_LIGHTS_HARDWIRED M S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M S2 APARTMENT_LIGHTS_HARDWIRED M S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
M CORRIDOR_LIGHTS_HARDWIRED M CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F6 SW APARTMENT_LIGHTS_HARDWIRED F6 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 NW APARTMENT_LIGHTS_HARDWIRED F6 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 SE APARTMENT_LIGHTS_HARDWIRED F6 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 NE APARTMENT_LIGHTS_HARDWIRED F6 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 N1 APARTMENT_LIGHTS_HARDWIRED F6 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 N2 APARTMENT_LIGHTS_HARDWIRED F6 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 S1 APARTMENT_LIGHTS_HARDWIRED F6 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 S2 APARTMENT_LIGHTS_HARDWIRED F6 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F6 CORRIDOR_LIGHTS_HARDWIRED F6 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F7 SW APARTMENT_LIGHTS_HARDWIRED F7 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 NW APARTMENT_LIGHTS_HARDWIRED F7 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 SE APARTMENT_LIGHTS_HARDWIRED F7 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 NE APARTMENT_LIGHTS_HARDWIRED F7 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 N1 APARTMENT_LIGHTS_HARDWIRED F7 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 N2 APARTMENT_LIGHTS_HARDWIRED F7 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 S1 APARTMENT_LIGHTS_HARDWIRED F7 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 S2 APARTMENT_LIGHTS_HARDWIRED F7 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F7 CORRIDOR_LIGHTS_HARDWIRED F7 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F8 SW APARTMENT_LIGHTS_HARDWIRED F8 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 NW APARTMENT_LIGHTS_HARDWIRED F8 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 SE APARTMENT_LIGHTS_HARDWIRED F8 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 NE APARTMENT_LIGHTS_HARDWIRED F8 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 N1 APARTMENT_LIGHTS_HARDWIRED F8 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 N2 APARTMENT_LIGHTS_HARDWIRED F8 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 S1 APARTMENT_LIGHTS_HARDWIRED F8 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 S2 APARTMENT_LIGHTS_HARDWIRED F8 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F8 CORRIDOR_LIGHTS_HARDWIRED F8 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F9 SW APARTMENT_LIGHTS_HARDWIRED F9 SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 NW APARTMENT_LIGHTS_HARDWIRED F9 NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 SE APARTMENT_LIGHTS_HARDWIRED F9 SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 NE APARTMENT_LIGHTS_HARDWIRED F9 NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 N1 APARTMENT_LIGHTS_HARDWIRED F9 N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 N2 APARTMENT_LIGHTS_HARDWIRED F9 N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 S1 APARTMENT_LIGHTS_HARDWIRED F9 S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 S2 APARTMENT_LIGHTS_HARDWIRED F9 S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
F9 CORRIDOR_LIGHTS_HARDWIRED F9 CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
T SW APARTMENT_LIGHTS_HARDWIRED T SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T NW APARTMENT_LIGHTS_HARDWIRED T NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T SE APARTMENT_LIGHTS_HARDWIRED T SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T NE APARTMENT_LIGHTS_HARDWIRED T NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T N1 APARTMENT_LIGHTS_HARDWIRED T N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T N2 APARTMENT_LIGHTS_HARDWIRED T N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T S1 APARTMENT_LIGHTS_HARDWIRED T S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T S2 APARTMENT_LIGHTS_HARDWIRED T S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
T CORRIDOR_LIGHTS_HARDWIRED T CORRIDOR 6.7128 77.66 521.30 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
G SW APARTMENT_LIGHTS_PLUGIN G SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G NW APARTMENT_LIGHTS_PLUGIN G NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
OFFICE_LIGHTS_PLUGIN OFFICE 14.7681 88.25 1303.26 GeneralLights-plugin LTG_OFF_SCH 62.05 168.00 61.07 0.0000 Y 14.94
G NE APARTMENT_LIGHTS_PLUGIN G NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G N1 APARTMENT_LIGHTS_PLUGIN G N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G N2 APARTMENT_LIGHTS_PLUGIN G N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G S1 APARTMENT_LIGHTS_PLUGIN G S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
G S2 APARTMENT_LIGHTS_PLUGIN G S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 SW APARTMENT_LIGHTS_PLUGIN F2 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 NW APARTMENT_LIGHTS_PLUGIN F2 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 SE APARTMENT_LIGHTS_PLUGIN F2 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 NE APARTMENT_LIGHTS_PLUGIN F2 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 N1 APARTMENT_LIGHTS_PLUGIN F2 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 N2 APARTMENT_LIGHTS_PLUGIN F2 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 S1 APARTMENT_LIGHTS_PLUGIN F2 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F2 S2 APARTMENT_LIGHTS_PLUGIN F2 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 SW APARTMENT_LIGHTS_PLUGIN F3 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 NW APARTMENT_LIGHTS_PLUGIN F3 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 SE APARTMENT_LIGHTS_PLUGIN F3 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 NE APARTMENT_LIGHTS_PLUGIN F3 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 N1 APARTMENT_LIGHTS_PLUGIN F3 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 N2 APARTMENT_LIGHTS_PLUGIN F3 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 S1 APARTMENT_LIGHTS_PLUGIN F3 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F3 S2 APARTMENT_LIGHTS_PLUGIN F3 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 SW APARTMENT_LIGHTS_PLUGIN F4 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 NW APARTMENT_LIGHTS_PLUGIN F4 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 SE APARTMENT_LIGHTS_PLUGIN F4 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 NE APARTMENT_LIGHTS_PLUGIN F4 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 N1 APARTMENT_LIGHTS_PLUGIN F4 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 N2 APARTMENT_LIGHTS_PLUGIN F4 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 S1 APARTMENT_LIGHTS_PLUGIN F4 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F4 S2 APARTMENT_LIGHTS_PLUGIN F4 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M SW APARTMENT_LIGHTS_PLUGIN M SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M NW APARTMENT_LIGHTS_PLUGIN M NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M SE APARTMENT_LIGHTS_PLUGIN M SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M NE APARTMENT_LIGHTS_PLUGIN M NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M N1 APARTMENT_LIGHTS_PLUGIN M N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M N2 APARTMENT_LIGHTS_PLUGIN M N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M S1 APARTMENT_LIGHTS_PLUGIN M S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M S2 APARTMENT_LIGHTS_PLUGIN M S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
M CORRIDOR_LIGHTS_PLUGIN M CORRIDOR 6.7128 77.66 521.30 GeneralLights-plugin LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 16.44
F6 SW APARTMENT_LIGHTS_PLUGIN F6 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 NW APARTMENT_LIGHTS_PLUGIN F6 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 SE APARTMENT_LIGHTS_PLUGIN F6 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 NE APARTMENT_LIGHTS_PLUGIN F6 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 N1 APARTMENT_LIGHTS_PLUGIN F6 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 N2 APARTMENT_LIGHTS_PLUGIN F6 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 S1 APARTMENT_LIGHTS_PLUGIN F6 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F6 S2 APARTMENT_LIGHTS_PLUGIN F6 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 SW APARTMENT_LIGHTS_PLUGIN F7 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 NW APARTMENT_LIGHTS_PLUGIN F7 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 SE APARTMENT_LIGHTS_PLUGIN F7 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 NE APARTMENT_LIGHTS_PLUGIN F7 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 N1 APARTMENT_LIGHTS_PLUGIN F7 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 N2 APARTMENT_LIGHTS_PLUGIN F7 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 S1 APARTMENT_LIGHTS_PLUGIN F7 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F7 S2 APARTMENT_LIGHTS_PLUGIN F7 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 SW APARTMENT_LIGHTS_PLUGIN F8 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 NW APARTMENT_LIGHTS_PLUGIN F8 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 SE APARTMENT_LIGHTS_PLUGIN F8 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 NE APARTMENT_LIGHTS_PLUGIN F8 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 N1 APARTMENT_LIGHTS_PLUGIN F8 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 N2 APARTMENT_LIGHTS_PLUGIN F8 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 S1 APARTMENT_LIGHTS_PLUGIN F8 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F8 S2 APARTMENT_LIGHTS_PLUGIN F8 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 SW APARTMENT_LIGHTS_PLUGIN F9 SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 NW APARTMENT_LIGHTS_PLUGIN F9 NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 SE APARTMENT_LIGHTS_PLUGIN F9 SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 NE APARTMENT_LIGHTS_PLUGIN F9 NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 N1 APARTMENT_LIGHTS_PLUGIN F9 N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 N2 APARTMENT_LIGHTS_PLUGIN F9 N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 S1 APARTMENT_LIGHTS_PLUGIN F9 S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
F9 S2 APARTMENT_LIGHTS_PLUGIN F9 S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T SW APARTMENT_LIGHTS_PLUGIN T SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T NW APARTMENT_LIGHTS_PLUGIN T NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T SE APARTMENT_LIGHTS_PLUGIN T SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T NE APARTMENT_LIGHTS_PLUGIN T NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T N1 APARTMENT_LIGHTS_PLUGIN T N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T N2 APARTMENT_LIGHTS_PLUGIN T N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T S1 APARTMENT_LIGHTS_PLUGIN T S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
T S2 APARTMENT_LIGHTS_PLUGIN T S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
Interior Lighting Total   2.2679 14974.03 33959.19               296.56


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 10364.00 AstronomicalClock -   83.58 83.58 162.61
Exterior Lighting Total 10364.00           162.61



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
CENTRAL BOILER Boiler:HotWater 277690.72 0.75    
CENTRAL TOWER EvaporativeFluidCooler:SingleSpeed 222152.57      


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
HEAT PUMP COOLING MODE AIRLOOP G SW Coil:Cooling:WaterToAirHeatPump:EquationFit   3596.54 2587.54 1009.00 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NW Coil:Cooling:WaterToAirHeatPump:EquationFit   3307.90 2383.07 924.83 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP OFFICE Coil:Cooling:WaterToAirHeatPump:EquationFit   5345.85 3810.25 1535.60 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP G NE Coil:Cooling:WaterToAirHeatPump:EquationFit   2432.32 1758.73 673.59 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   1637.65 1184.05 453.59 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP G N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   1611.58 1165.49 446.09 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2368.79 1669.08 699.71 0.70 0.00    
HEAT PUMP COOLING MODE AIRLOOP G S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2458.09 1733.38 724.71 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4552.52 3285.58 1266.94 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4131.93 2985.45 1146.48 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4472.48 3205.42 1267.06 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3191.48 2317.14 874.34 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2144.05 1552.22 591.83 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2123.24 1537.37 585.88 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3019.75 2145.15 874.60 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP F2 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3052.86 2168.94 883.92 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4581.89 3312.29 1269.60 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4168.90 3021.74 1147.16 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4232.16 3040.79 1191.37 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3247.74 2365.18 882.56 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2189.90 1589.45 600.45 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2169.19 1574.65 594.54 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3078.57 2192.08 886.49 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP F3 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3094.11 2203.24 890.86 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4603.95 3334.15 1269.80 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4191.21 3043.74 1147.47 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4241.97 3053.68 1188.30 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3285.06 2394.05 891.01 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2212.07 1608.64 603.43 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2191.45 1593.89 597.55 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3108.37 2216.99 891.38 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP F4 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3121.41 2226.36 895.05 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4650.74 3372.60 1278.14 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4238.51 3082.52 1155.99 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP M SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4298.30 3098.90 1199.40 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP M NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3334.45 2434.15 900.30 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2257.05 1643.51 613.54 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP M N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2236.50 1628.81 607.69 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3159.62 2256.70 902.92 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP M S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3172.29 2265.80 906.49 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4615.94 3351.85 1264.09 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4202.20 3060.66 1141.53 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4274.97 3086.17 1188.80 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3302.10 2414.75 887.35 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2222.52 1621.16 601.36 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2202.14 1606.57 595.58 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3130.01 2237.82 892.20 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP F6 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3142.63 2246.88 895.75 0.71 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4609.57 3350.95 1258.62 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4195.59 3059.57 1136.02 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4278.69 3092.38 1186.31 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3298.33 2415.42 882.91 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2216.20 1618.67 597.54 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2195.95 1604.16 591.80 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3127.68 2238.26 889.42 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F7 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3140.28 2247.31 892.97 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4620.51 3362.08 1258.42 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4206.46 3070.62 1135.84 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4297.40 3109.01 1188.39 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3310.28 2427.05 883.23 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2227.45 1628.52 598.93 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2207.34 1614.11 593.23 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3141.27 2249.94 891.33 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F8 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3153.89 2259.01 894.88 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SW Coil:Cooling:WaterToAirHeatPump:EquationFit   4769.64 3472.09 1297.55 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NW Coil:Cooling:WaterToAirHeatPump:EquationFit   4350.19 3176.71 1173.49 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 SE Coil:Cooling:WaterToAirHeatPump:EquationFit   4412.41 3194.52 1217.90 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 NE Coil:Cooling:WaterToAirHeatPump:EquationFit   3369.06 2472.21 896.86 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   2353.31 1720.28 633.03 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   2333.10 1705.79 627.31 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3236.76 2320.35 916.41 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP F9 S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3250.41 2330.28 920.13 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SW Coil:Cooling:WaterToAirHeatPump:EquationFit   5933.42 4300.71 1632.71 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NW Coil:Cooling:WaterToAirHeatPump:EquationFit   5349.33 3888.52 1460.81 0.73 0.00    
HEAT PUMP COOLING MODE AIRLOOP T SE Coil:Cooling:WaterToAirHeatPump:EquationFit   5483.46 3966.99 1516.47 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP T NE Coil:Cooling:WaterToAirHeatPump:EquationFit   4300.51 3116.70 1183.81 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N1 Coil:Cooling:WaterToAirHeatPump:EquationFit   3301.70 2372.87 928.83 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP T N2 Coil:Cooling:WaterToAirHeatPump:EquationFit   3306.27 2374.11 932.16 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S1 Coil:Cooling:WaterToAirHeatPump:EquationFit   4452.28 3195.64 1256.65 0.72 0.00    
HEAT PUMP COOLING MODE AIRLOOP T S2 Coil:Cooling:WaterToAirHeatPump:EquationFit   4463.37 3203.58 1259.79 0.72 0.00    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
None            


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
HEAT PUMP HEATING MODE AIRLOOP G SW Coil:Heating:WaterToAirHeatPump:EquationFit   3596.54 0.00
HEAT PUMP HEATING MODE AIRLOOP G NW Coil:Heating:WaterToAirHeatPump:EquationFit   3307.90 0.00
HEAT PUMP HEATING MODE AIRLOOP OFFICE Coil:Heating:WaterToAirHeatPump:EquationFit   5345.85 0.00
HEAT PUMP HEATING MODE AIRLOOP G NE Coil:Heating:WaterToAirHeatPump:EquationFit   2432.32 0.00
HEAT PUMP HEATING MODE AIRLOOP G N1 Coil:Heating:WaterToAirHeatPump:EquationFit   1637.65 0.00
HEAT PUMP HEATING MODE AIRLOOP G N2 Coil:Heating:WaterToAirHeatPump:EquationFit   1611.58 0.00
HEAT PUMP HEATING MODE AIRLOOP G S1 Coil:Heating:WaterToAirHeatPump:EquationFit   2368.79 0.00
HEAT PUMP HEATING MODE AIRLOOP G S2 Coil:Heating:WaterToAirHeatPump:EquationFit   2458.09 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4552.52 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4131.93 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4472.48 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3191.48 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2144.05 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2123.24 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3019.75 0.00
HEAT PUMP HEATING MODE AIRLOOP F2 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3052.86 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4581.89 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4168.90 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4232.16 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3247.74 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2189.90 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2169.19 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3078.57 0.00
HEAT PUMP HEATING MODE AIRLOOP F3 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3094.11 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4603.95 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4191.21 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4241.97 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3285.06 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2212.07 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2191.45 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3108.37 0.00
HEAT PUMP HEATING MODE AIRLOOP F4 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3121.41 0.00
HEAT PUMP HEATING MODE AIRLOOP M SW Coil:Heating:WaterToAirHeatPump:EquationFit   4650.74 0.00
HEAT PUMP HEATING MODE AIRLOOP M NW Coil:Heating:WaterToAirHeatPump:EquationFit   4238.51 0.00
HEAT PUMP HEATING MODE AIRLOOP M SE Coil:Heating:WaterToAirHeatPump:EquationFit   4298.30 0.00
HEAT PUMP HEATING MODE AIRLOOP M NE Coil:Heating:WaterToAirHeatPump:EquationFit   3334.45 0.00
HEAT PUMP HEATING MODE AIRLOOP M N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2257.05 0.00
HEAT PUMP HEATING MODE AIRLOOP M N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2236.50 0.00
HEAT PUMP HEATING MODE AIRLOOP M S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3159.62 0.00
HEAT PUMP HEATING MODE AIRLOOP M S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3172.29 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4615.94 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4202.20 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4274.97 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3302.10 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2222.52 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2202.14 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3130.01 0.00
HEAT PUMP HEATING MODE AIRLOOP F6 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3142.63 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4609.57 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4195.59 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4278.69 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3298.33 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2216.20 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2195.95 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3127.68 0.00
HEAT PUMP HEATING MODE AIRLOOP F7 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3140.28 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4620.51 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4206.46 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4297.40 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3310.28 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2227.45 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2207.34 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3141.27 0.00
HEAT PUMP HEATING MODE AIRLOOP F8 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3153.89 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SW Coil:Heating:WaterToAirHeatPump:EquationFit   4769.64 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NW Coil:Heating:WaterToAirHeatPump:EquationFit   4350.19 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 SE Coil:Heating:WaterToAirHeatPump:EquationFit   4412.41 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 NE Coil:Heating:WaterToAirHeatPump:EquationFit   3369.06 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N1 Coil:Heating:WaterToAirHeatPump:EquationFit   2353.31 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 N2 Coil:Heating:WaterToAirHeatPump:EquationFit   2333.10 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S1 Coil:Heating:WaterToAirHeatPump:EquationFit   3236.76 0.00
HEAT PUMP HEATING MODE AIRLOOP F9 S2 Coil:Heating:WaterToAirHeatPump:EquationFit   3250.41 0.00
HEAT PUMP HEATING MODE AIRLOOP T SW Coil:Heating:WaterToAirHeatPump:EquationFit   5933.42 0.00
HEAT PUMP HEATING MODE AIRLOOP T NW Coil:Heating:WaterToAirHeatPump:EquationFit   5349.33 0.00
HEAT PUMP HEATING MODE AIRLOOP T SE Coil:Heating:WaterToAirHeatPump:EquationFit   5483.46 0.00
HEAT PUMP HEATING MODE AIRLOOP T NE Coil:Heating:WaterToAirHeatPump:EquationFit   4300.51 0.00
HEAT PUMP HEATING MODE AIRLOOP T N1 Coil:Heating:WaterToAirHeatPump:EquationFit   3301.70 0.00
HEAT PUMP HEATING MODE AIRLOOP T N2 Coil:Heating:WaterToAirHeatPump:EquationFit   3306.27 0.00
HEAT PUMP HEATING MODE AIRLOOP T S1 Coil:Heating:WaterToAirHeatPump:EquationFit   4452.28 0.00
HEAT PUMP HEATING MODE AIRLOOP T S2 Coil:Heating:WaterToAirHeatPump:EquationFit   4463.37 0.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW Coil:Heating:Electric   3760.47 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW Coil:Heating:Electric   3775.08 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE Coil:Heating:Electric   4652.81 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE Coil:Heating:Electric   3770.34 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 Coil:Heating:Electric   2902.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 Coil:Heating:Electric   2902.17 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 Coil:Heating:Electric   2884.58 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 Coil:Heating:Electric   2890.75 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW Coil:Heating:Electric   3613.42 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW Coil:Heating:Electric   3620.19 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE Coil:Heating:Electric   3627.05 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE Coil:Heating:Electric   3615.49 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 Coil:Heating:Electric   2552.26 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 Coil:Heating:Electric   2552.15 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 Coil:Heating:Electric   2548.35 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 Coil:Heating:Electric   2549.39 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW Coil:Heating:Electric   3612.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW Coil:Heating:Electric   3619.74 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE Coil:Heating:Electric   3610.92 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE Coil:Heating:Electric   3615.99 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 Coil:Heating:Electric   2505.97 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 Coil:Heating:Electric   2505.88 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 Coil:Heating:Electric   2499.87 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 Coil:Heating:Electric   2499.96 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW Coil:Heating:Electric   3678.92 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW Coil:Heating:Electric   3685.23 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE Coil:Heating:Electric   3676.25 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE Coil:Heating:Electric   3682.36 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 Coil:Heating:Electric   2533.67 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 Coil:Heating:Electric   2533.60 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 Coil:Heating:Electric   2527.99 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 Coil:Heating:Electric   2527.95 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW Coil:Heating:Electric   3724.22 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW Coil:Heating:Electric   3728.46 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE Coil:Heating:Electric   3722.17 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE Coil:Heating:Electric   3726.39 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 Coil:Heating:Electric   2546.94 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 Coil:Heating:Electric   2546.89 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 Coil:Heating:Electric   2543.31 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 Coil:Heating:Electric   2543.26 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW Coil:Heating:Electric   3825.60 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW Coil:Heating:Electric   3829.61 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE Coil:Heating:Electric   3824.25 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE Coil:Heating:Electric   3828.26 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 Coil:Heating:Electric   2621.07 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 Coil:Heating:Electric   2621.04 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 Coil:Heating:Electric   2617.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 Coil:Heating:Electric   2617.62 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW Coil:Heating:Electric   3898.88 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW Coil:Heating:Electric   3901.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE Coil:Heating:Electric   3898.18 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE Coil:Heating:Electric   3900.95 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 Coil:Heating:Electric   2670.23 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 Coil:Heating:Electric   2670.21 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 Coil:Heating:Electric   2668.08 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 Coil:Heating:Electric   2668.06 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW Coil:Heating:Electric   3977.43 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW Coil:Heating:Electric   3978.75 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE Coil:Heating:Electric   3977.33 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE Coil:Heating:Electric   3978.65 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 Coil:Heating:Electric   2727.07 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 Coil:Heating:Electric   2727.06 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 Coil:Heating:Electric   2726.37 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 Coil:Heating:Electric   2726.37 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW Coil:Heating:Electric   4203.83 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW Coil:Heating:Electric   4200.93 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE Coil:Heating:Electric   4204.28 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE Coil:Heating:Electric   4201.39 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 Coil:Heating:Electric   2921.24 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 Coil:Heating:Electric   2921.25 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 Coil:Heating:Electric   2924.33 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 Coil:Heating:Electric   2924.34 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW Coil:Heating:Electric   4999.34 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW Coil:Heating:Electric   5003.61 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE Coil:Heating:Electric   5000.21 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE Coil:Heating:Electric   5004.47 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 Coil:Heating:Electric   3771.06 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 Coil:Heating:Electric   3771.08 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 Coil:Heating:Electric   3764.02 1.00
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 Coil:Heating:Electric   3764.04 1.00


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
AIRLOOP G SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.27 309.14 1160.84 1.00 General
AIRLOOP G NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 285.54 1160.84 1.00 General
AIRLOOP OFFICE SUPPLY FAN Fan:OnOff 0.54 622.50 0.39 447.15 1160.84 1.00 General
AIRLOOP G NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 207.59 1160.84 1.00 General
AIRLOOP G N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 139.67 1160.84 1.00 General
AIRLOOP G N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 137.40 1160.84 1.00 General
AIRLOOP G S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 190.65 1160.84 1.00 General
AIRLOOP G S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 198.50 1160.84 1.00 General
AIRLOOP F2 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.34 395.56 1160.84 1.00 General
AIRLOOP F2 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 360.16 1160.84 1.00 General
AIRLOOP F2 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.33 380.12 1160.84 1.00 General
AIRLOOP F2 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 276.81 1160.84 1.00 General
AIRLOOP F2 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 185.07 1160.84 1.00 General
AIRLOOP F2 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 183.26 1160.84 1.00 General
AIRLOOP F2 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.21 249.24 1160.84 1.00 General
AIRLOOP F2 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 252.15 1160.84 1.00 General
AIRLOOP F3 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.34 398.67 1160.84 1.00 General
AIRLOOP F3 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 364.43 1160.84 1.00 General
AIRLOOP F3 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 360.33 1160.84 1.00 General
AIRLOOP F3 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 283.11 1160.84 1.00 General
AIRLOOP F3 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 189.87 1160.84 1.00 General
AIRLOOP F3 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 188.06 1160.84 1.00 General
AIRLOOP F3 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 255.23 1160.84 1.00 General
AIRLOOP F3 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 256.59 1160.84 1.00 General
AIRLOOP F4 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.35 401.67 1160.84 1.00 General
AIRLOOP F4 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 367.45 1160.84 1.00 General
AIRLOOP F4 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 362.22 1160.84 1.00 General
AIRLOOP F4 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 286.31 1160.84 1.00 General
AIRLOOP F4 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 192.40 1160.84 1.00 General
AIRLOOP F4 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 190.59 1160.84 1.00 General
AIRLOOP F4 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 258.46 1160.84 1.00 General
AIRLOOP F4 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 259.61 1160.84 1.00 General
AIRLOOP M SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.35 406.65 1160.84 1.00 General
AIRLOOP M NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 372.47 1160.84 1.00 General
AIRLOOP M SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 368.02 1160.84 1.00 General
AIRLOOP M NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 291.47 1160.84 1.00 General
AIRLOOP M N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 196.81 1160.84 1.00 General
AIRLOOP M N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 195.01 1160.84 1.00 General
AIRLOOP M S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 263.47 1160.84 1.00 General
AIRLOOP M S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 264.59 1160.84 1.00 General
AIRLOOP F6 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.35 404.32 1160.84 1.00 General
AIRLOOP F6 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 370.00 1160.84 1.00 General
AIRLOOP F6 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 366.67 1160.84 1.00 General
AIRLOOP F6 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 289.29 1160.84 1.00 General
AIRLOOP F6 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 194.19 1160.84 1.00 General
AIRLOOP F6 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 192.40 1160.84 1.00 General
AIRLOOP F6 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 261.29 1160.84 1.00 General
AIRLOOP F6 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 262.40 1160.84 1.00 General
AIRLOOP F7 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.35 404.40 1160.84 1.00 General
AIRLOOP F7 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 370.05 1160.84 1.00 General
AIRLOOP F7 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 367.61 1160.84 1.00 General
AIRLOOP F7 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 289.54 1160.84 1.00 General
AIRLOOP F7 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 193.99 1160.84 1.00 General
AIRLOOP F7 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 192.21 1160.84 1.00 General
AIRLOOP F7 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 261.45 1160.84 1.00 General
AIRLOOP F7 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 262.56 1160.84 1.00 General
AIRLOOP F8 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.35 405.94 1160.84 1.00 General
AIRLOOP F8 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 371.58 1160.84 1.00 General
AIRLOOP F8 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 369.82 1160.84 1.00 General
AIRLOOP F8 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 291.13 1160.84 1.00 General
AIRLOOP F8 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 195.30 1160.84 1.00 General
AIRLOOP F8 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 193.53 1160.84 1.00 General
AIRLOOP F8 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 262.98 1160.84 1.00 General
AIRLOOP F8 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 264.09 1160.84 1.00 General
AIRLOOP F9 SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.36 419.62 1160.84 1.00 General
AIRLOOP F9 NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.33 384.78 1160.84 1.00 General
AIRLOOP F9 SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.33 380.47 1160.84 1.00 General
AIRLOOP F9 NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 296.83 1160.84 1.00 General
AIRLOOP F9 N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 206.64 1160.84 1.00 General
AIRLOOP F9 N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 204.86 1160.84 1.00 General
AIRLOOP F9 S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 271.70 1160.84 1.00 General
AIRLOOP F9 S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 272.92 1160.84 1.00 General
AIRLOOP T SW SUPPLY FAN Fan:OnOff 0.54 622.50 0.45 518.61 1160.84 1.00 General
AIRLOOP T NW SUPPLY FAN Fan:OnOff 0.54 622.50 0.41 470.37 1160.84 1.00 General
AIRLOOP T SE SUPPLY FAN Fan:OnOff 0.54 622.50 0.41 475.54 1160.84 1.00 General
AIRLOOP T NE SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 371.05 1160.84 1.00 General
AIRLOOP T N1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 278.94 1160.84 1.00 General
AIRLOOP T N2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 278.74 1160.84 1.00 General
AIRLOOP T S1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.33 379.17 1160.84 1.00 General
AIRLOOP T S2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.33 380.14 1160.84 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
SHWSYS1 PUMP Pump:ConstantSpeed Intermittent 29891.00 0.0003 36.93 127739.32 0.30
PLANT CIRC PUMP Pump:ConstantSpeed Intermittent 224180.02 0.0060 1928.84 319344.75 0.90


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
SHWSYS1 WATER HEATER WaterHeater:Mixed 2.27 175842.64 0.80 0.00 0.00



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 2606.58 3127.90 0.222 0.266 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 32.69 0.00627
G NW APARTMENT 2407.56 2889.07 0.205 0.246 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 31.44 0.00627
OFFICE 3770.33 4524.39 0.321 0.385 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 36.70 0.00627
G NE APARTMENT 1750.40 2100.49 0.149 0.179 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 11:00:00 32.86 0.00627
G N1 APARTMENT 1177.60 1413.13 0.100 0.120 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 30.19 0.00627
G N2 APARTMENT 1158.49 1390.18 0.099 0.118 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 30.19 0.00627
G S1 APARTMENT 1607.53 1929.04 0.137 0.164 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 36.70 0.00627
G S2 APARTMENT 1673.68 2008.42 0.142 0.171 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 36.70 0.00627
F2 SW APARTMENT 3335.27 4002.33 0.284 0.341 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 32.69 0.00627
F2 NW APARTMENT 3036.83 3644.20 0.259 0.310 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 31.44 0.00627
F2 SE APARTMENT 3205.16 3846.19 0.273 0.327 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 36.70 0.00627
F2 NE APARTMENT 2334.05 2800.86 0.199 0.238 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 11:00:00 32.86 0.00627
F2 N1 APARTMENT 1560.49 1872.59 0.133 0.159 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 30.19 0.00627
F2 N2 APARTMENT 1545.15 1854.18 0.132 0.158 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 30.19 0.00627
F2 S1 APARTMENT 2101.54 2521.85 0.179 0.215 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 36.70 0.00627
F2 S2 APARTMENT 2126.08 2551.30 0.181 0.217 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 36.70 0.00627
F3 SW APARTMENT 3361.53 4033.83 0.286 0.343 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 33.11 0.00627
F3 NW APARTMENT 3072.82 3687.38 0.262 0.314 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 32.07 0.00627
F3 SE APARTMENT 3038.30 3645.96 0.259 0.310 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 36.70 0.00627
F3 NE APARTMENT 2387.16 2864.59 0.203 0.244 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 11:00:00 32.86 0.00627
F3 N1 APARTMENT 1600.93 1921.12 0.136 0.164 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 30.19 0.00627
F3 N2 APARTMENT 1585.64 1902.76 0.135 0.162 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 30.19 0.00627
F3 S1 APARTMENT 2152.04 2582.45 0.183 0.220 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 36.70 0.00627
F3 S2 APARTMENT 2163.56 2596.28 0.184 0.221 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 36.70 0.00627
F4 SW APARTMENT 3386.86 4064.23 0.288 0.346 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 33.11 0.00627
F4 NW APARTMENT 3098.27 3717.93 0.264 0.317 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 32.07 0.00627
F4 SE APARTMENT 3054.23 3665.08 0.260 0.312 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 36.70 0.00627
F4 NE APARTMENT 2414.17 2897.00 0.206 0.247 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 11:15:00 33.28 0.00627
F4 N1 APARTMENT 1622.25 1946.70 0.138 0.166 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 30.19 0.00627
F4 N2 APARTMENT 1607.00 1928.40 0.137 0.164 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 30.19 0.00627
F4 S1 APARTMENT 2179.31 2615.18 0.186 0.223 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 36.70 0.00627
F4 S2 APARTMENT 2188.98 2626.78 0.186 0.224 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 36.70 0.00627
M SW APARTMENT 3428.88 4114.65 0.292 0.350 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 33.11 0.00627
M NW APARTMENT 3140.62 3768.74 0.267 0.321 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 32.07 0.00627
M SE APARTMENT 3103.16 3723.79 0.264 0.317 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 36.70 0.00627
M NE APARTMENT 2457.73 2949.28 0.209 0.251 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 11:15:00 33.28 0.00627
M N1 APARTMENT 1659.49 1991.39 0.141 0.170 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 30.19 0.00627
M N2 APARTMENT 1644.28 1973.14 0.140 0.168 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 30.19 0.00627
M S1 APARTMENT 2221.59 2665.90 0.189 0.227 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 36.70 0.00627
M S2 APARTMENT 2230.98 2677.18 0.190 0.228 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 36.70 0.00627
F6 SW APARTMENT 3409.24 4091.08 0.290 0.348 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 33.11 0.00627
F6 NW APARTMENT 3119.81 3743.77 0.266 0.319 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 32.07 0.00627
F6 SE APARTMENT 3091.77 3710.12 0.263 0.316 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 36.70 0.00627
F6 NE APARTMENT 2439.30 2927.16 0.208 0.249 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 11:15:00 33.28 0.00627
F6 N1 APARTMENT 1637.40 1964.88 0.139 0.167 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 30.19 0.00627
F6 N2 APARTMENT 1622.31 1946.77 0.138 0.166 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 30.19 0.00627
F6 S1 APARTMENT 2203.15 2643.78 0.188 0.225 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 36.70 0.00627
F6 S2 APARTMENT 2212.51 2655.01 0.188 0.226 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 36.70 0.00627
F7 SW APARTMENT 3409.93 4091.92 0.290 0.348 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 33.11 0.00627
F7 NW APARTMENT 3120.28 3744.33 0.266 0.319 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 32.07 0.00627
F7 SE APARTMENT 3099.76 3719.71 0.264 0.317 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 36.70 0.00627
F7 NE APARTMENT 2441.47 2929.76 0.208 0.249 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 11:15:00 33.28 0.00627
F7 N1 APARTMENT 1635.71 1962.86 0.139 0.167 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 30.19 0.00627
F7 N2 APARTMENT 1620.70 1944.84 0.138 0.166 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 30.19 0.00627
F7 S1 APARTMENT 2204.55 2645.46 0.188 0.225 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 36.70 0.00627
F7 S2 APARTMENT 2213.89 2656.67 0.188 0.226 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 36.70 0.00627
F8 SW APARTMENT 3422.92 4107.50 0.291 0.350 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 33.11 0.00627
F8 NW APARTMENT 3133.16 3759.80 0.267 0.320 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 32.07 0.00627
F8 SE APARTMENT 3118.38 3742.05 0.265 0.319 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 36.70 0.00627
F8 NE APARTMENT 2454.84 2945.80 0.209 0.251 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 11:15:00 33.28 0.00627
F8 N1 APARTMENT 1646.70 1976.04 0.140 0.168 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 30.19 0.00627
F8 N2 APARTMENT 1631.78 1958.14 0.139 0.167 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 30.19 0.00627
F8 S1 APARTMENT 2217.46 2660.95 0.189 0.227 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 36.70 0.00627
F8 S2 APARTMENT 2226.82 2672.18 0.190 0.228 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 36.70 0.00627
F9 SW APARTMENT 3538.27 4245.93 0.301 0.361 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 33.11 0.00627
F9 NW APARTMENT 3244.45 3893.34 0.276 0.331 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 32.07 0.00627
F9 SE APARTMENT 3208.19 3849.82 0.273 0.328 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 36.70 0.00627
F9 NE APARTMENT 2502.89 3003.47 0.213 0.256 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 11:15:00 33.28 0.00627
F9 N1 APARTMENT 1742.35 2090.83 0.148 0.178 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 30.19 0.00627
F9 N2 APARTMENT 1727.36 2072.83 0.147 0.176 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 19:00:00 30.19 0.00627
F9 S1 APARTMENT 2290.96 2749.15 0.195 0.234 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:45:00 36.70 0.00627
F9 S2 APARTMENT 2301.26 2761.51 0.196 0.235 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 36.70 0.00627
T SW APARTMENT 4373.02 5247.62 0.372 0.447 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 16:15:00 35.36 0.00627
T NW APARTMENT 3966.25 4759.50 0.338 0.405 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 33.53 0.00627
T SE APARTMENT 4009.85 4811.82 0.341 0.410 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 36.70 0.00627
T NE APARTMENT 3128.76 3754.52 0.266 0.320 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:45:00 36.70 0.00627
T N1 APARTMENT 2352.04 2822.45 0.200 0.240 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 15:30:00 36.20 0.00627
T N2 APARTMENT 2350.30 2820.35 0.200 0.240 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 15:15:00 36.45 0.00627
T S1 APARTMENT 3197.14 3836.57 0.272 0.327 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 36.70 0.00627
T S2 APARTMENT 3205.35 3846.43 0.273 0.327 BOISE AIR TERMINAL UO ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 36.70 0.00627


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 2251.93 2702.31 0.109 0.131 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -16.30 0.00098
G NW APARTMENT 2264.28 2717.14 0.110 0.131 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -16.30 0.00098
OFFICE 2572.00 3086.40 0.124 0.149 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 18:45:00 -16.30 0.00098
G NE APARTMENT 2260.27 2712.33 0.109 0.131 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -16.30 0.00098
G N1 APARTMENT 1526.19 1831.43 0.074 0.089 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -16.30 0.00098
G N2 APARTMENT 1526.10 1831.32 0.074 0.089 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -16.30 0.00098
G S1 APARTMENT 1511.22 1813.47 0.073 0.088 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -16.30 0.00098
G S2 APARTMENT 1516.44 1819.72 0.073 0.088 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -16.30 0.00098
F2 SW APARTMENT 2127.60 2553.12 0.103 0.124 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F2 NW APARTMENT 2133.33 2559.99 0.103 0.124 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F2 SE APARTMENT 2139.13 2566.96 0.103 0.124 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F2 NE APARTMENT 2129.36 2555.23 0.103 0.124 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F2 N1 APARTMENT 1230.22 1476.26 0.060 0.071 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F2 N2 APARTMENT 1230.12 1476.15 0.060 0.071 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F2 S1 APARTMENT 1226.90 1472.29 0.059 0.071 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F2 S2 APARTMENT 1227.79 1473.34 0.059 0.071 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F3 SW APARTMENT 2127.04 2552.45 0.103 0.123 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F3 NW APARTMENT 2132.95 2559.55 0.103 0.124 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F3 SE APARTMENT 2125.50 2550.60 0.103 0.123 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F3 NE APARTMENT 2129.79 2555.75 0.103 0.124 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F3 N1 APARTMENT 1191.07 1429.29 0.058 0.069 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F3 N2 APARTMENT 1190.99 1429.19 0.058 0.069 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F3 S1 APARTMENT 1185.92 1423.10 0.057 0.069 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F3 S2 APARTMENT 1185.99 1423.19 0.057 0.069 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F4 SW APARTMENT 2183.01 2619.61 0.106 0.127 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F4 NW APARTMENT 2188.34 2626.01 0.106 0.127 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F4 SE APARTMENT 2180.75 2616.90 0.106 0.127 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F4 NE APARTMENT 2185.92 2623.10 0.106 0.127 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F4 N1 APARTMENT 1214.50 1457.41 0.059 0.071 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F4 N2 APARTMENT 1214.45 1457.34 0.059 0.071 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F4 S1 APARTMENT 1209.70 1451.65 0.059 0.070 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F4 S2 APARTMENT 1209.67 1451.60 0.059 0.070 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
M SW APARTMENT 2221.32 2665.59 0.107 0.129 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
M NW APARTMENT 2224.91 2669.89 0.108 0.129 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
M SE APARTMENT 2219.59 2663.51 0.107 0.129 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
M NE APARTMENT 2223.16 2667.79 0.108 0.129 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
M N1 APARTMENT 1225.73 1470.88 0.059 0.071 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
M N2 APARTMENT 1225.69 1470.83 0.059 0.071 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
M S1 APARTMENT 1222.66 1467.19 0.059 0.071 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
M S2 APARTMENT 1222.62 1467.14 0.059 0.071 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F6 SW APARTMENT 2307.06 2768.48 0.112 0.134 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F6 NW APARTMENT 2310.45 2772.54 0.112 0.134 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F6 SE APARTMENT 2305.92 2767.10 0.112 0.134 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F6 NE APARTMENT 2309.31 2771.17 0.112 0.134 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F6 N1 APARTMENT 1288.42 1546.10 0.062 0.075 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F6 N2 APARTMENT 1288.39 1546.07 0.062 0.075 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F6 S1 APARTMENT 1285.53 1542.64 0.062 0.075 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F6 S2 APARTMENT 1285.50 1542.60 0.062 0.075 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F7 SW APARTMENT 2369.03 2842.84 0.115 0.138 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F7 NW APARTMENT 2371.37 2845.65 0.115 0.138 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F7 SE APARTMENT 2368.44 2842.13 0.115 0.137 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F7 NE APARTMENT 2370.78 2844.94 0.115 0.138 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F7 N1 APARTMENT 1330.00 1595.99 0.064 0.077 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F7 N2 APARTMENT 1329.98 1595.98 0.064 0.077 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F7 S1 APARTMENT 1328.17 1593.81 0.064 0.077 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F7 S2 APARTMENT 1328.16 1593.79 0.064 0.077 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F8 SW APARTMENT 2435.47 2922.56 0.118 0.141 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F8 NW APARTMENT 2436.58 2923.90 0.118 0.141 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F8 SE APARTMENT 2435.38 2922.46 0.118 0.141 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F8 NE APARTMENT 2436.50 2923.79 0.118 0.141 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F8 N1 APARTMENT 1378.06 1653.67 0.067 0.080 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F8 N2 APARTMENT 1378.06 1653.67 0.067 0.080 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F8 S1 APARTMENT 1377.47 1652.97 0.067 0.080 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F8 S2 APARTMENT 1377.47 1652.97 0.067 0.080 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F9 SW APARTMENT 2626.92 3152.30 0.127 0.152 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F9 NW APARTMENT 2624.47 3149.36 0.127 0.152 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F9 SE APARTMENT 2627.30 3152.77 0.127 0.153 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F9 NE APARTMENT 2624.85 3149.82 0.127 0.152 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F9 N1 APARTMENT 1542.26 1850.72 0.075 0.090 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F9 N2 APARTMENT 1542.27 1850.73 0.075 0.090 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F9 S1 APARTMENT 1544.88 1853.85 0.075 0.090 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
F9 S2 APARTMENT 1544.88 1853.86 0.075 0.090 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
T SW APARTMENT 3299.66 3959.59 0.160 0.192 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
T NW APARTMENT 3303.26 3963.91 0.160 0.192 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
T SE APARTMENT 3300.39 3960.46 0.160 0.192 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
T NE APARTMENT 3303.99 3964.79 0.160 0.192 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
T N1 APARTMENT 2260.92 2713.10 0.109 0.131 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
T N2 APARTMENT 2260.94 2713.12 0.109 0.131 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
T S1 APARTMENT 2254.97 2705.96 0.109 0.131 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098
T S2 APARTMENT 2254.99 2705.98 0.109 0.131 BOISE AIR TERMINAL UO ANN HTG 99.6% CONDNS DB 12/21 15:00:00 -16.30 0.00098


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
AIRLOOP G SW 0.27 0.27 0.13 0.13
AIRLOOP G NW 0.25 0.25 0.13 0.13
AIRLOOP OFFICE 0.39 0.39 0.15 0.15
AIRLOOP G NE 0.18 0.18 0.13 0.13
AIRLOOP G N1 0.12 0.12 0.09 0.09
AIRLOOP G N2 0.12 0.12 0.09 0.09
AIRLOOP G S1 0.16 0.16 0.09 0.09
AIRLOOP G S2 0.17 0.17 0.09 0.09
AIRLOOP F2 SW 0.34 0.34 0.12 0.12
AIRLOOP F2 NW 0.31 0.31 0.12 0.12
AIRLOOP F2 SE 0.33 0.33 0.12 0.12
AIRLOOP F2 NE 0.24 0.24 0.12 0.12
AIRLOOP F2 N1 0.16 0.16 0.07 0.07
AIRLOOP F2 N2 0.16 0.16 0.07 0.07
AIRLOOP F2 S1 0.21 0.21 0.07 0.07
AIRLOOP F2 S2 0.22 0.22 0.07 0.07
AIRLOOP F3 SW 0.34 0.34 0.12 0.12
AIRLOOP F3 NW 0.31 0.31 0.12 0.12
AIRLOOP F3 SE 0.31 0.31 0.12 0.12
AIRLOOP F3 NE 0.24 0.24 0.12 0.12
AIRLOOP F3 N1 0.16 0.16 0.07 0.07
AIRLOOP F3 N2 0.16 0.16 0.07 0.07
AIRLOOP F3 S1 0.22 0.22 0.07 0.07
AIRLOOP F3 S2 0.22 0.22 0.07 0.07
AIRLOOP F4 SW 0.35 0.35 0.13 0.13
AIRLOOP F4 NW 0.32 0.32 0.13 0.13
AIRLOOP F4 SE 0.31 0.31 0.13 0.13
AIRLOOP F4 NE 0.25 0.25 0.13 0.13
AIRLOOP F4 N1 0.17 0.17 0.07 0.07
AIRLOOP F4 N2 0.16 0.16 0.07 0.07
AIRLOOP F4 S1 0.22 0.22 0.07 0.07
AIRLOOP F4 S2 0.22 0.22 0.07 0.07
AIRLOOP M SW 0.35 0.35 0.13 0.13
AIRLOOP M NW 0.32 0.32 0.13 0.13
AIRLOOP M SE 0.32 0.32 0.13 0.13
AIRLOOP M NE 0.25 0.25 0.13 0.13
AIRLOOP M N1 0.17 0.17 0.07 0.07
AIRLOOP M N2 0.17 0.17 0.07 0.07
AIRLOOP M S1 0.23 0.23 0.07 0.07
AIRLOOP M S2 0.23 0.23 0.07 0.07
AIRLOOP F6 SW 0.35 0.35 0.13 0.13
AIRLOOP F6 NW 0.32 0.32 0.13 0.13
AIRLOOP F6 SE 0.32 0.32 0.13 0.13
AIRLOOP F6 NE 0.25 0.25 0.13 0.13
AIRLOOP F6 N1 0.17 0.17 0.07 0.07
AIRLOOP F6 N2 0.17 0.17 0.07 0.07
AIRLOOP F6 S1 0.23 0.23 0.07 0.07
AIRLOOP F6 S2 0.23 0.23 0.07 0.07
AIRLOOP F7 SW 0.35 0.35 0.14 0.14
AIRLOOP F7 NW 0.32 0.32 0.14 0.14
AIRLOOP F7 SE 0.32 0.32 0.14 0.14
AIRLOOP F7 NE 0.25 0.25 0.14 0.14
AIRLOOP F7 N1 0.17 0.17 0.08 0.08
AIRLOOP F7 N2 0.17 0.17 0.08 0.08
AIRLOOP F7 S1 0.23 0.23 0.08 0.08
AIRLOOP F7 S2 0.23 0.23 0.08 0.08
AIRLOOP F8 SW 0.35 0.35 0.14 0.14
AIRLOOP F8 NW 0.32 0.32 0.14 0.14
AIRLOOP F8 SE 0.32 0.32 0.14 0.14
AIRLOOP F8 NE 0.25 0.25 0.14 0.14
AIRLOOP F8 N1 0.17 0.17 0.08 0.08
AIRLOOP F8 N2 0.17 0.17 0.08 0.08
AIRLOOP F8 S1 0.23 0.23 0.08 0.08
AIRLOOP F8 S2 0.23 0.23 0.08 0.08
AIRLOOP F9 SW 0.36 0.36 0.15 0.15
AIRLOOP F9 NW 0.33 0.33 0.15 0.15
AIRLOOP F9 SE 0.33 0.33 0.15 0.15
AIRLOOP F9 NE 0.26 0.26 0.15 0.15
AIRLOOP F9 N1 0.18 0.18 0.09 0.09
AIRLOOP F9 N2 0.18 0.18 0.09 0.09
AIRLOOP F9 S1 0.23 0.23 0.09 0.09
AIRLOOP F9 S2 0.24 0.24 0.09 0.09
AIRLOOP T SW 0.45 0.45 0.19 0.19
AIRLOOP T NW 0.41 0.41 0.19 0.19
AIRLOOP T SE 0.41 0.41 0.19 0.19
AIRLOOP T NE 0.32 0.32 0.19 0.19
AIRLOOP T N1 0.24 0.24 0.13 0.13
AIRLOOP T N2 0.24 0.24 0.13 0.13
AIRLOOP T S1 0.33 0.33 0.13 0.13
AIRLOOP T S2 0.33 0.33 0.13 0.13



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 1766.00 5679.50 170.25
G NW APARTMENT 1557.25 6419.00 413.50
OFFICE 879.25 858.00 15.50
G NE APARTMENT 1632.00 6364.25 434.75
G N1 APARTMENT 977.25 6746.25 106.75
G N2 APARTMENT 981.75 6747.00 108.75
G S1 APARTMENT 1340.75 5917.25 44.75
G S2 APARTMENT 1390.50 5821.75 41.50
F2 SW APARTMENT 2469.50 4280.25 38.75
F2 NW APARTMENT 1799.00 5409.00 131.25
F2 SE APARTMENT 2794.75 4002.75 28.50
F2 NE APARTMENT 1926.00 5450.25 148.50
F2 N1 APARTMENT 1321.00 5812.00 22.50
F2 N2 APARTMENT 1324.75 5816.50 22.50
F2 S1 APARTMENT 2167.75 4143.50 7.75
F2 S2 APARTMENT 2205.50 4092.50 7.75
F3 SW APARTMENT 2649.50 4052.00 30.50
F3 NW APARTMENT 1907.00 5182.75 105.00
F3 SE APARTMENT 2782.00 3994.25 29.25
F3 NE APARTMENT 2020.00 5249.50 122.25
F3 N1 APARTMENT 1455.50 5487.25 17.75
F3 N2 APARTMENT 1456.00 5485.75 17.75
F3 S1 APARTMENT 2451.00 3703.50 7.00
F3 S2 APARTMENT 2469.25 3686.50 7.00
F4 SW APARTMENT 2665.25 4046.50 30.25
F4 NW APARTMENT 1926.50 5146.75 105.75
F4 SE APARTMENT 2771.50 4020.75 31.50
F4 NE APARTMENT 2039.00 5218.00 122.75
F4 N1 APARTMENT 1489.50 5384.50 16.00
F4 N2 APARTMENT 1491.50 5388.50 16.50
F4 S1 APARTMENT 2520.50 3646.25 7.00
F4 S2 APARTMENT 2532.00 3637.25 7.00
M SW APARTMENT 2668.75 4062.75 28.75
M NW APARTMENT 1940.75 5149.50 103.75
M SE APARTMENT 2768.25 4043.75 30.75
M NE APARTMENT 2049.50 5221.50 117.50
M N1 APARTMENT 1514.75 5358.25 14.25
M N2 APARTMENT 1519.00 5363.50 14.25
M S1 APARTMENT 2549.75 3639.00 6.75
M S2 APARTMENT 2559.50 3634.25 6.75
F6 SW APARTMENT 2549.25 4213.00 36.25
F6 NW APARTMENT 1868.75 5277.00 130.50
F6 SE APARTMENT 2656.25 4181.25 39.75
F6 NE APARTMENT 1961.00 5355.25 143.50
F6 N1 APARTMENT 1430.00 5527.25 18.00
F6 N2 APARTMENT 1431.00 5533.75 18.00
F6 S1 APARTMENT 2388.00 3818.25 7.25
F6 S2 APARTMENT 2396.25 3812.75 7.25
F7 SW APARTMENT 2463.50 4312.75 39.75
F7 NW APARTMENT 1819.00 5386.25 144.50
F7 SE APARTMENT 2586.75 4294.25 44.00
F7 NE APARTMENT 1909.25 5451.25 155.00
F7 N1 APARTMENT 1385.00 5647.75 19.00
F7 N2 APARTMENT 1382.50 5653.25 19.00
F7 S1 APARTMENT 2298.25 3961.00 7.50
F7 S2 APARTMENT 2304.50 3957.50 7.50
F8 SW APARTMENT 2397.50 4404.50 45.50
F8 NW APARTMENT 1795.00 5473.50 160.00
F8 SE APARTMENT 2533.00 4395.75 50.75
F8 NE APARTMENT 1869.00 5532.25 170.50
F8 N1 APARTMENT 1357.25 5738.00 21.50
F8 N2 APARTMENT 1357.25 5746.75 22.25
F8 S1 APARTMENT 2224.25 4103.00 7.50
F8 S2 APARTMENT 2237.50 4101.25 7.50
F9 SW APARTMENT 2345.00 4540.25 77.00
F9 NW APARTMENT 1838.50 5582.50 228.50
F9 SE APARTMENT 2481.25 4525.25 84.00
F9 NE APARTMENT 1912.50 5631.25 245.25
F9 N1 APARTMENT 1365.25 5832.00 36.25
F9 N2 APARTMENT 1366.75 5833.50 36.50
F9 S1 APARTMENT 2114.75 4316.00 7.25
F9 S2 APARTMENT 2124.75 4308.00 7.25
T SW APARTMENT 2950.50 5136.00 676.50
T NW APARTMENT 2753.25 5917.75 1060.25
T SE APARTMENT 3072.50 5060.50 680.75
T NE APARTMENT 2886.25 5911.75 1060.50
T N1 APARTMENT 1914.25 6075.00 462.75
T N2 APARTMENT 1923.75 6067.25 464.25
T S1 APARTMENT 2410.25 4892.50 212.50
T S2 APARTMENT 2427.00 4892.00 213.00
G CORRIDOR 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00
Facility 4534.50 6916.25 1144.50
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 1.75 49.25 1.75 49.25
G NW APARTMENT 0.00 30.00 0.00 30.00
OFFICE 1.50 2.75 0.00 2.75
G NE APARTMENT 1.75 13.75 1.75 13.75
G N1 APARTMENT 4.75 62.25 4.75 62.25
G N2 APARTMENT 7.25 65.50 7.25 65.50
G S1 APARTMENT 2.50 43.00 2.50 43.00
G S2 APARTMENT 3.00 30.50 3.00 30.50
F2 SW APARTMENT 0.25 47.75 0.25 47.75
F2 NW APARTMENT 0.25 25.75 0.25 25.75
F2 SE APARTMENT 2.50 0.00 2.50 0.00
F2 NE APARTMENT 1.50 12.25 1.50 12.25
F2 N1 APARTMENT 6.00 46.50 6.00 46.50
F2 N2 APARTMENT 7.50 49.50 7.50 49.50
F2 S1 APARTMENT 2.25 60.00 2.25 60.00
F2 S2 APARTMENT 2.00 54.25 2.00 54.25
F3 SW APARTMENT 0.50 53.75 0.50 53.75
F3 NW APARTMENT 0.25 30.25 0.25 30.25
F3 SE APARTMENT 1.25 10.75 1.25 10.75
F3 NE APARTMENT 1.00 17.50 1.00 17.50
F3 N1 APARTMENT 5.25 60.00 5.25 60.00
F3 N2 APARTMENT 6.25 63.00 6.25 63.00
F3 S1 APARTMENT 4.25 68.00 4.25 68.00
F3 S2 APARTMENT 4.75 63.50 4.75 63.50
F4 SW APARTMENT 0.50 57.00 0.50 57.00
F4 NW APARTMENT 1.00 33.00 1.00 33.00
F4 SE APARTMENT 1.75 13.25 1.75 13.25
F4 NE APARTMENT 1.25 20.50 1.25 20.50
F4 N1 APARTMENT 4.25 69.25 4.25 69.25
F4 N2 APARTMENT 5.50 71.50 5.50 71.50
F4 S1 APARTMENT 2.50 66.75 2.50 66.75
F4 S2 APARTMENT 3.00 62.75 3.00 62.75
M SW APARTMENT 0.75 60.50 0.75 60.50
M NW APARTMENT 0.00 36.00 0.00 36.00
M SE APARTMENT 1.00 13.00 1.00 13.00
M NE APARTMENT 1.25 24.00 1.25 24.00
M N1 APARTMENT 5.25 72.50 5.25 72.50
M N2 APARTMENT 5.00 74.75 5.00 74.75
M S1 APARTMENT 2.50 63.25 2.50 63.25
M S2 APARTMENT 3.25 61.00 3.25 61.00
F6 SW APARTMENT 0.25 62.50 0.25 62.50
F6 NW APARTMENT 0.25 38.50 0.25 38.50
F6 SE APARTMENT 1.00 13.25 1.00 13.25
F6 NE APARTMENT 1.25 27.25 1.25 27.25
F6 N1 APARTMENT 5.75 77.25 5.75 77.25
F6 N2 APARTMENT 6.50 79.75 6.50 79.75
F6 S1 APARTMENT 3.25 62.00 3.25 62.00
F6 S2 APARTMENT 2.75 58.50 2.75 58.50
F7 SW APARTMENT 0.50 65.00 0.50 65.00
F7 NW APARTMENT 0.25 40.00 0.25 40.00
F7 SE APARTMENT 1.25 14.25 1.25 14.25
F7 NE APARTMENT 0.50 30.75 0.50 30.75
F7 N1 APARTMENT 5.00 81.25 5.00 81.25
F7 N2 APARTMENT 5.50 85.00 5.50 85.00
F7 S1 APARTMENT 2.50 58.25 2.50 58.25
F7 S2 APARTMENT 2.75 56.50 2.75 56.50
F8 SW APARTMENT 0.25 67.25 0.25 67.25
F8 NW APARTMENT 0.25 40.50 0.25 40.50
F8 SE APARTMENT 0.25 13.50 0.25 13.50
F8 NE APARTMENT 1.25 33.50 1.25 33.50
F8 N1 APARTMENT 6.00 82.50 6.00 82.50
F8 N2 APARTMENT 6.00 87.25 6.00 87.25
F8 S1 APARTMENT 4.25 55.50 4.25 55.50
F8 S2 APARTMENT 4.25 53.25 4.25 53.25
F9 SW APARTMENT 0.50 58.25 0.50 58.25
F9 NW APARTMENT 0.00 39.75 0.00 39.75
F9 SE APARTMENT 0.25 9.25 0.25 9.25
F9 NE APARTMENT 1.00 43.75 1.00 43.75
F9 N1 APARTMENT 3.00 72.75 3.00 72.75
F9 N2 APARTMENT 4.25 75.50 4.25 75.50
F9 S1 APARTMENT 2.75 48.00 2.75 48.00
F9 S2 APARTMENT 4.25 45.75 4.25 45.75
T SW APARTMENT 0.00 27.50 0.00 27.50
T NW APARTMENT 0.00 34.25 0.00 34.25
T SE APARTMENT 0.00 2.25 0.00 2.25
T NE APARTMENT 0.00 13.00 0.00 13.00
T N1 APARTMENT 0.25 27.75 0.25 27.75
T N2 APARTMENT 0.00 22.25 0.00 22.25
T S1 APARTMENT 1.00 12.50 1.00 12.50
T S2 APARTMENT 0.50 12.25 0.50 12.25
G CORRIDOR 0.00 0.00 0.00 0.00
F2 CORRIDOR 0.00 0.00 0.00 0.00
F3 CORRIDOR 0.00 0.00 0.00 0.00
F4 CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
F6 CORRIDOR 0.00 0.00 0.00 0.00
F7 CORRIDOR 0.00 0.00 0.00 0.00
F8 CORRIDOR 0.00 0.00 0.00 0.00
F9 CORRIDOR 0.00 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
Facility 134.50 179.25 133.00 179.25
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.360 0.152 0.000 0.245
G NW APARTMENT 1.71 2.50 268.96 0.360 0.152 0.000 0.234
OFFICE 0.94 1.00 268.96 0.529 0.164 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.360 0.152 0.000 0.235
G N1 APARTMENT 1.71 2.50 268.96 0.360 0.092 0.000 0.227
G N2 APARTMENT 1.71 2.50 268.97 0.360 0.092 0.000 0.227
G S1 APARTMENT 1.71 2.50 268.96 0.360 0.092 0.000 0.242
G S2 APARTMENT 1.71 2.50 268.97 0.360 0.092 0.000 0.243
F2 SW APARTMENT 1.71 2.50 268.96 0.361 0.219 0.000 0.278
F2 NW APARTMENT 1.71 2.50 268.96 0.360 0.218 0.000 0.267
F2 SE APARTMENT 1.71 2.50 268.96 0.361 0.219 0.000 0.279
F2 NE APARTMENT 1.71 2.50 268.96 0.360 0.218 0.000 0.267
F2 N1 APARTMENT 1.71 2.50 268.96 0.360 0.132 0.000 0.262
F2 N2 APARTMENT 1.71 2.50 268.97 0.360 0.132 0.000 0.262
F2 S1 APARTMENT 1.71 2.50 268.96 0.361 0.132 0.000 0.276
F2 S2 APARTMENT 1.71 2.50 268.97 0.361 0.132 0.000 0.276
F3 SW APARTMENT 1.71 2.50 268.96 0.361 0.259 0.000 0.300
F3 NW APARTMENT 1.71 2.50 268.96 0.360 0.259 0.000 0.289
F3 SE APARTMENT 1.71 2.50 268.96 0.361 0.259 0.000 0.301
F3 NE APARTMENT 1.71 2.50 268.96 0.360 0.258 0.000 0.289
F3 N1 APARTMENT 1.71 2.50 268.96 0.360 0.156 0.000 0.285
F3 N2 APARTMENT 1.71 2.50 268.97 0.360 0.156 0.000 0.285
F3 S1 APARTMENT 1.71 2.50 268.96 0.361 0.156 0.000 0.299
F3 S2 APARTMENT 1.71 2.50 268.97 0.361 0.156 0.000 0.299
F4 SW APARTMENT 1.71 2.50 268.96 0.361 0.289 0.000 0.308
F4 NW APARTMENT 1.71 2.50 268.96 0.360 0.289 0.000 0.296
F4 SE APARTMENT 1.71 2.50 268.96 0.361 0.289 0.000 0.309
F4 NE APARTMENT 1.71 2.50 268.96 0.360 0.289 0.000 0.297
F4 N1 APARTMENT 1.71 2.50 268.96 0.360 0.174 0.000 0.293
F4 N2 APARTMENT 1.71 2.50 268.97 0.360 0.174 0.000 0.293
F4 S1 APARTMENT 1.71 2.50 268.96 0.361 0.175 0.000 0.307
F4 S2 APARTMENT 1.71 2.50 268.97 0.361 0.175 0.000 0.307
M SW APARTMENT 1.71 2.50 268.96 0.361 0.314 0.000 0.321
M NW APARTMENT 1.71 2.50 268.96 0.360 0.314 0.000 0.308
M SE APARTMENT 1.71 2.50 268.96 0.361 0.314 0.000 0.321
M NE APARTMENT 1.71 2.50 268.96 0.360 0.314 0.000 0.308
M N1 APARTMENT 1.71 2.50 268.96 0.360 0.189 0.000 0.304
M N2 APARTMENT 1.71 2.50 268.97 0.360 0.189 0.000 0.305
M S1 APARTMENT 1.71 2.50 268.96 0.361 0.190 0.000 0.320
M S2 APARTMENT 1.71 2.50 268.97 0.361 0.190 0.000 0.320
F6 SW APARTMENT 1.71 2.50 268.96 0.360 0.336 0.000 0.331
F6 NW APARTMENT 1.71 2.50 268.96 0.360 0.335 0.000 0.318
F6 SE APARTMENT 1.71 2.50 268.96 0.360 0.336 0.000 0.332
F6 NE APARTMENT 1.71 2.50 268.96 0.360 0.335 0.000 0.318
F6 N1 APARTMENT 1.71 2.50 268.96 0.360 0.202 0.000 0.314
F6 N2 APARTMENT 1.71 2.50 268.97 0.360 0.202 0.000 0.314
F6 S1 APARTMENT 1.71 2.50 268.96 0.361 0.203 0.000 0.330
F6 S2 APARTMENT 1.71 2.50 268.97 0.361 0.203 0.000 0.330
F7 SW APARTMENT 1.71 2.50 268.96 0.360 0.355 0.000 0.340
F7 NW APARTMENT 1.71 2.50 268.96 0.360 0.354 0.000 0.326
F7 SE APARTMENT 1.71 2.50 268.96 0.360 0.355 0.000 0.341
F7 NE APARTMENT 1.71 2.50 268.96 0.360 0.354 0.000 0.326
F7 N1 APARTMENT 1.71 2.50 268.96 0.360 0.214 0.000 0.322
F7 N2 APARTMENT 1.71 2.50 268.97 0.360 0.214 0.000 0.322
F7 S1 APARTMENT 1.71 2.50 268.96 0.361 0.214 0.000 0.339
F7 S2 APARTMENT 1.71 2.50 268.97 0.361 0.214 0.000 0.339
F8 SW APARTMENT 1.71 2.50 268.96 0.360 0.372 0.000 0.350
F8 NW APARTMENT 1.71 2.50 268.96 0.360 0.371 0.000 0.335
F8 SE APARTMENT 1.71 2.50 268.96 0.360 0.372 0.000 0.350
F8 NE APARTMENT 1.71 2.50 268.96 0.360 0.371 0.000 0.335
F8 N1 APARTMENT 1.71 2.50 268.96 0.360 0.224 0.000 0.331
F8 N2 APARTMENT 1.71 2.50 268.97 0.360 0.224 0.000 0.331
F8 S1 APARTMENT 1.71 2.50 268.96 0.361 0.224 0.000 0.349
F8 S2 APARTMENT 1.71 2.50 268.97 0.361 0.224 0.000 0.349
F9 SW APARTMENT 1.71 2.50 268.96 0.360 0.388 0.000 0.358
F9 NW APARTMENT 1.71 2.50 268.96 0.360 0.387 0.000 0.342
F9 SE APARTMENT 1.71 2.50 268.96 0.360 0.388 0.000 0.359
F9 NE APARTMENT 1.71 2.50 268.96 0.360 0.387 0.000 0.343
F9 N1 APARTMENT 1.71 2.50 268.96 0.360 0.233 0.000 0.338
F9 N2 APARTMENT 1.71 2.50 268.97 0.360 0.233 0.000 0.338
F9 S1 APARTMENT 1.71 2.50 268.96 0.361 0.234 0.000 0.357
F9 S2 APARTMENT 1.71 2.50 268.97 0.361 0.234 0.000 0.357
T SW APARTMENT 1.71 2.50 268.96 0.360 0.402 0.000 0.363
T NW APARTMENT 1.71 2.50 268.96 0.360 0.402 0.000 0.349
T SE APARTMENT 1.71 2.50 268.96 0.360 0.402 0.000 0.365
T NE APARTMENT 1.71 2.50 268.96 0.360 0.402 0.000 0.349
T N1 APARTMENT 1.71 2.50 268.96 0.360 0.242 0.000 0.345
T N2 APARTMENT 1.71 2.50 268.97 0.360 0.242 0.000 0.346
T S1 APARTMENT 1.71 2.50 268.96 0.360 0.242 0.000 0.363
T S2 APARTMENT 1.71 2.50 268.97 0.360 0.242 0.000 0.363
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
OFFICE 0.94 1.00 268.96 0.512 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.348 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.348 0.000 0.000 0.000
F2 SW APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F2 NW APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F2 SE APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F2 NE APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F2 N1 APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F2 N2 APARTMENT 1.71 2.50 268.97 0.348 0.000 0.000 0.000
F2 S1 APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F2 S2 APARTMENT 1.71 2.50 268.97 0.348 0.000 0.000 0.000
F3 SW APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F3 NW APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F3 SE APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F3 NE APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F3 N1 APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F3 N2 APARTMENT 1.71 2.50 268.97 0.348 0.000 0.000 0.000
F3 S1 APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F3 S2 APARTMENT 1.71 2.50 268.97 0.348 0.000 0.000 0.000
F4 SW APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F4 NW APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F4 SE APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F4 NE APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F4 N1 APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F4 N2 APARTMENT 1.71 2.50 268.97 0.348 0.000 0.000 0.000
F4 S1 APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F4 S2 APARTMENT 1.71 2.50 268.97 0.348 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 0.348 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 0.348 0.000 0.000 0.000
F6 SW APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F6 NW APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F6 SE APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F6 NE APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F6 N1 APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F6 N2 APARTMENT 1.71 2.50 268.97 0.348 0.000 0.000 0.000
F6 S1 APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F6 S2 APARTMENT 1.71 2.50 268.97 0.348 0.000 0.000 0.000
F7 SW APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F7 NW APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F7 SE APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F7 NE APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F7 N1 APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F7 N2 APARTMENT 1.71 2.50 268.97 0.348 0.000 0.000 0.000
F7 S1 APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F7 S2 APARTMENT 1.71 2.50 268.97 0.348 0.000 0.000 0.000
F8 SW APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F8 NW APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F8 SE APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F8 NE APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F8 N1 APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F8 N2 APARTMENT 1.71 2.50 268.97 0.348 0.000 0.000 0.000
F8 S1 APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F8 S2 APARTMENT 1.71 2.50 268.97 0.348 0.000 0.000 0.000
F9 SW APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F9 NW APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F9 SE APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F9 NE APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F9 N1 APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F9 N2 APARTMENT 1.71 2.50 268.97 0.348 0.000 0.000 0.000
F9 S1 APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
F9 S2 APARTMENT 1.71 2.50 268.97 0.348 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.348 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.96 0.348 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.348 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Surfaces by Class

Total Outdoors
Wall 420 140
Floor 90 9
Roof 90 9
Internal Mass 80 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 140 140
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 80
Conditioned Zones 80
Unconditioned Zones 10
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 4156
Defaulted Fields 814
Fields with Defaults 11184
Autosized Fields 1293
Autosizable Fields 1630
Autocalculated Fields 907
Autocalculatable Fields 1710



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 2969.94 60621.67 15-MAY-02:45 171034.84 31-JUL-18:00
Electricity:Building 1433.88 25760.85 01-JAN-03:15 70162.48 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity 296.56 6715.87 01-JAN-00:15 14401.37 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 242.55 5824.91 01-JAN-00:15 11484.27 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:OFFICE 39.38 663.42 01-JAN-00:15 2934.49 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 29.88 469.18 01-JAN-00:15 2345.88 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:G CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F2 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F2 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F2 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F2 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F3 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F3 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F3 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F3 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F4 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F4 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F4 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F4 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:M SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M CORRIDOR 32.88 1042.61 01-JAN-00:15 1042.61 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 32.88 1042.61 01-JAN-00:15 1042.61 01-JAN-00:15
Electricity:Zone:F6 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F6 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F6 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F6 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F7 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F7 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F7 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F7 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F8 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F8 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F8 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F8 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:F9 SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:F9 S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:F9 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
InteriorLights:Electricity:Zone:F9 CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
Electricity:Zone:T SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T CORRIDOR 179.47 1701.70 01-JAN-00:15 10868.20 01-JAN-07:15
InteriorLights:Electricity:Zone:T CORRIDOR 16.44 521.30 01-JAN-00:15 521.30 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 54.01 890.97 01-JAN-00:15 2917.11 01-JAN-19:15
InteriorEquipment:Electricity 1137.32 19044.98 01-JAN-03:15 57142.09 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 1137.32 19044.98 01-JAN-03:15 57142.09 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 9.50 194.24 01-JAN-00:15 588.62 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F2 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F3 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F4 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F6 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F7 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F8 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:F9 S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T CORRIDOR 163.03 1180.40 01-JAN-00:15 10346.90 01-JAN-07:15
Fans:Electricity 750.51 23798.64 01-JAN-01:00 23798.64 01-JAN-00:15
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F2 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F3 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F4 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F6 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F7 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F8 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:F9 S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Electricity:HVAC 1299.78 24459.89 15-MAY-02:45 96703.75 04-AUG-16:15
ElectricityProduced:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityProduced:HVAC 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricityProduced 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 2969.94 60621.67 15-MAY-02:45 171034.84 31-JUL-18:00
ElectricityPurchased:Plant 2969.94 60621.67 15-MAY-02:45 171034.84 31-JUL-18:00
Cogeneration:ElectricityPurchased 2969.94 60621.67 15-MAY-02:45 171034.84 31-JUL-18:00
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 2969.94 60621.67 15-MAY-02:45 171034.84 31-JUL-18:00
ElectricityNet:Plant 2969.94 60621.67 15-MAY-02:45 171034.84 31-JUL-18:00
Cogeneration:ElectricityNet 2969.94 60621.67 15-MAY-02:45 171034.84 31-JUL-18:00
ExteriorLights:Electricity 162.61 0.00 01-JAN-08:30 10364.00 01-JAN-00:15
General:ExteriorLights:Electricity 162.61 0.00 01-JAN-08:30 10364.00 01-JAN-00:15
General:Fans:Electricity 750.51 23798.64 01-JAN-01:00 23798.64 01-JAN-00:15
Cooling:Electricity 353.52 0.00 01-JAN-00:15 70909.91 04-AUG-16:15
Heating:Electricity 159.58 0.00 10-FEB-15:00 47114.35 04-JAN-05:00
Electricity:Plant 73.67 36.93 03-MAR-18:45 4489.15 31-JUL-17:00
HeatRejection:Electricity 12.51 0.00 01-JAN-00:15 2523.38 31-JUL-17:00
Boiler Parasitic:Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Pumps:Electricity 61.16 36.93 03-MAR-18:45 1965.77 01-JAN-06:15
WIRED_LTG_ELECTRICITY 0.44 0.00 01-JAN-00:15 21.60 01-JAN-19:30
WIRED_INT_EQUIP 979.40 1018.50 01-JAN-00:15 10185.00 01-JAN-07:15


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 1709.56 2357.00 08-FEB-00:15 268387.14 28-DEC-08:15
Gas:Plant 1709.56 2357.00 08-FEB-00:15 268387.14 28-DEC-08:15
WaterSystems:Gas 1165.01 2357.00 01-JAN-00:15 83068.13 15-FEB-08:00
Water Heater:WaterSystems:Gas 1165.01 2357.00 01-JAN-00:15 83068.13 15-FEB-08:00
Heating:Gas 544.55 0.00 26-JAN-13:45 193240.80 04-JAN-05:15
Boiler:Heating:Gas 544.55 0.00 26-JAN-13:45 193240.80 04-JAN-05:15


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
PlantLoopCoolingDemand:Facility 1395.21 0.00 01-JAN-00:15 322183.83 31-JUL-18:00
PlantLoopCoolingDemand:HVAC 1395.21 0.00 01-JAN-00:15 322183.83 31-JUL-18:00
CoolingCoils:PlantLoopCoolingDemand 1395.21 0.00 01-JAN-00:15 322183.83 31-JUL-18:00


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 6069.22 0.00 01-JAN-02:15 0.00 21-JUL-17:30
Water:Plant 6069.22 0.00 01-JAN-02:15 0.00 21-JUL-17:30
WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
MainsWater:Facility 6069.22 0.00 01-JAN-02:15 0.00 21-JUL-17:30
MainsWater:Plant 6069.22 0.00 01-JAN-02:15 0.00 21-JUL-17:30
WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
sub cat:WaterSystems:Water 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
sub cat:WaterSystems:MainsWater 4778.51 0.00 01-JAN-02:15 0.00 01-JAN-07:15
HeatRejection:Water 1290.70 0.00 01-JAN-00:15 0.00 21-JUL-17:30
HeatRejection:MainsWater 1290.70 0.00 01-JAN-00:15 0.00 21-JUL-17:30


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 1355.76 461.65 19-AUG-01:15 204301.12 04-JAN-08:00
PlantLoopHeatingDemand:Plant 906.75 461.65 19-AUG-01:15 62523.17 14-FEB-07:30
WaterSystems:PlantLoopHeatingDemand 906.75 461.65 19-AUG-01:15 62523.17 14-FEB-07:30
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 4386.69 6293.58 29-OCT-01:15 535247.24 28-DEC-08:15
EnergyTransfer:Building 1416.65 4509.90 27-OCT-18:00 201289.76 06-AUG-16:15
EnergyTransfer:Zone:G SW APARTMENT 15.37 0.04 07-SEP-04:00 2833.04 30-SEP-16:15
Heating:EnergyTransfer 391.14 0.00 05-FEB-17:00 152529.46 04-JAN-05:00
Heating:EnergyTransfer:Zone:G SW APARTMENT 5.10 0.00 01-JAN-13:15 1828.68 04-JAN-08:15
Cooling:EnergyTransfer 1025.51 0.00 01-JAN-00:15 201289.76 06-AUG-16:15
Cooling:EnergyTransfer:Zone:G SW APARTMENT 10.28 0.00 01-JAN-00:15 2833.04 30-SEP-16:15
EnergyTransfer:Zone:G NW APARTMENT 14.76 0.02 08-MAY-01:30 2517.62 08-JUL-19:15
Heating:EnergyTransfer:Zone:G NW APARTMENT 8.08 0.00 23-JAN-16:30 1906.80 13-JAN-08:30
Cooling:EnergyTransfer:Zone:G NW APARTMENT 6.69 0.00 01-JAN-00:15 2517.62 08-JUL-19:15
EnergyTransfer:Zone:OFFICE 23.51 0.00 17-OCT-03:00 3980.29 28-SEP-14:15
Heating:EnergyTransfer:Zone:OFFICE 3.73 0.00 01-JAN-13:15 1724.49 28-DEC-08:00
Cooling:EnergyTransfer:Zone:OFFICE 19.78 0.00 01-JAN-00:15 3980.29 28-SEP-14:15
EnergyTransfer:Zone:G NE APARTMENT 14.57 0.02 13-OCT-04:15 1900.04 04-JAN-08:15
Heating:EnergyTransfer:Zone:G NE APARTMENT 7.76 0.00 05-FEB-16:45 1900.04 04-JAN-08:15
Cooling:EnergyTransfer:Zone:G NE APARTMENT 6.81 0.00 01-JAN-00:15 1819.82 22-JUL-08:30
EnergyTransfer:Zone:G N1 APARTMENT 9.35 0.02 03-MAY-09:15 1290.07 03-MAR-13:45
Heating:EnergyTransfer:Zone:G N1 APARTMENT 4.18 0.00 30-JAN-17:15 1290.07 03-MAR-13:45
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 5.17 0.00 01-JAN-00:15 1275.22 08-JUL-19:30
EnergyTransfer:Zone:G N2 APARTMENT 9.35 0.01 26-MAY-13:15 1289.18 03-MAR-13:45
Heating:EnergyTransfer:Zone:G N2 APARTMENT 4.18 0.00 30-JAN-17:15 1289.18 03-MAR-13:45
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 5.18 0.00 01-JAN-00:15 1254.90 08-JUL-19:30
EnergyTransfer:Zone:G S1 APARTMENT 11.02 0.00 09-DEC-05:30 1918.13 31-AUG-13:45
Heating:EnergyTransfer:Zone:G S1 APARTMENT 1.80 0.00 01-JAN-12:45 1091.19 28-DEC-08:15
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 9.21 0.00 01-JAN-00:15 1918.13 31-AUG-13:45
EnergyTransfer:Zone:G S2 APARTMENT 11.18 0.01 14-JUL-06:00 1989.72 31-AUG-13:45
Heating:EnergyTransfer:Zone:G S2 APARTMENT 1.70 0.00 01-JAN-12:45 1077.52 28-DEC-08:15
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 9.47 0.00 01-JAN-00:15 1989.72 31-AUG-13:45
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F2 SW APARTMENT 20.49 0.04 19-APR-22:15 3563.28 30-SEP-16:15
Heating:EnergyTransfer:Zone:F2 SW APARTMENT 3.60 0.00 01-JAN-13:15 1902.90 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F2 SW APARTMENT 16.89 0.00 01-JAN-00:15 3563.28 30-SEP-16:15
EnergyTransfer:Zone:F2 NW APARTMENT 17.42 0.00 16-SEP-00:45 3207.17 14-JUL-18:30
Heating:EnergyTransfer:Zone:F2 NW APARTMENT 6.89 0.00 23-JAN-16:15 2120.36 28-DEC-10:00
Cooling:EnergyTransfer:Zone:F2 NW APARTMENT 10.53 0.00 01-JAN-00:15 3207.17 14-JUL-18:30
EnergyTransfer:Zone:F2 SE APARTMENT 21.75 0.02 29-DEC-21:15 3439.50 28-SEP-14:15
Heating:EnergyTransfer:Zone:F2 SE APARTMENT 3.04 0.00 01-JAN-13:15 1846.07 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F2 SE APARTMENT 18.71 0.00 01-JAN-00:15 3439.50 28-SEP-14:15
EnergyTransfer:Zone:F2 NE APARTMENT 17.46 0.01 09-MAY-17:45 2412.48 13-JUL-10:15
Heating:EnergyTransfer:Zone:F2 NE APARTMENT 6.62 0.00 20-JAN-19:00 2042.40 04-JAN-05:00
Cooling:EnergyTransfer:Zone:F2 NE APARTMENT 10.84 0.00 01-JAN-00:15 2412.48 13-JUL-10:15
EnergyTransfer:Zone:F2 N1 APARTMENT 10.75 0.01 09-JAN-18:30 1695.73 08-JUL-19:30
Heating:EnergyTransfer:Zone:F2 N1 APARTMENT 2.48 0.00 03-JAN-17:15 1536.03 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F2 N1 APARTMENT 8.27 0.00 01-JAN-00:15 1695.73 08-JUL-19:30
EnergyTransfer:Zone:F2 N2 APARTMENT 10.77 0.04 13-FEB-12:30 1679.02 08-JUL-19:30
Heating:EnergyTransfer:Zone:F2 N2 APARTMENT 2.48 0.00 03-JAN-17:15 1533.57 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F2 N2 APARTMENT 8.29 0.00 01-JAN-00:15 1679.02 08-JUL-19:30
EnergyTransfer:Zone:F2 S1 APARTMENT 16.22 0.06 05-MAY-10:30 2452.95 31-AUG-13:30
Heating:EnergyTransfer:Zone:F2 S1 APARTMENT 0.87 0.00 01-JAN-09:45 966.29 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F2 S1 APARTMENT 15.35 0.00 01-JAN-00:15 2452.95 31-AUG-13:30
EnergyTransfer:Zone:F2 S2 APARTMENT 16.36 0.07 21-DEC-02:30 2479.44 31-AUG-13:30
Heating:EnergyTransfer:Zone:F2 S2 APARTMENT 0.85 0.00 01-JAN-09:45 961.12 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F2 S2 APARTMENT 15.51 0.00 01-JAN-00:15 2479.44 31-AUG-13:30
EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F2 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F3 SW APARTMENT 21.41 0.01 16-SEP-03:30 3573.58 30-SEP-16:15
Heating:EnergyTransfer:Zone:F3 SW APARTMENT 3.53 0.00 01-JAN-13:15 2054.99 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F3 SW APARTMENT 17.89 0.00 01-JAN-00:15 3573.58 30-SEP-16:15
EnergyTransfer:Zone:F3 NW APARTMENT 18.06 0.05 27-OCT-01:45 3254.70 08-JUL-19:15
Heating:EnergyTransfer:Zone:F3 NW APARTMENT 6.84 0.00 20-JAN-19:00 2311.71 28-DEC-10:00
Cooling:EnergyTransfer:Zone:F3 NW APARTMENT 11.22 0.00 01-JAN-00:15 3254.70 08-JUL-19:15
EnergyTransfer:Zone:F3 SE APARTMENT 21.88 0.02 23-MAR-17:45 3254.40 28-SEP-14:15
Heating:EnergyTransfer:Zone:F3 SE APARTMENT 3.37 0.00 01-JAN-13:15 2049.05 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F3 SE APARTMENT 18.51 0.00 01-JAN-00:15 3254.40 28-SEP-14:15
EnergyTransfer:Zone:F3 NE APARTMENT 18.18 0.01 07-APR-02:45 2479.85 22-JUN-10:15
Heating:EnergyTransfer:Zone:F3 NE APARTMENT 6.61 0.00 20-JAN-10:00 2178.13 04-JAN-05:00
Cooling:EnergyTransfer:Zone:F3 NE APARTMENT 11.57 0.00 01-JAN-00:15 2479.85 22-JUN-10:15
EnergyTransfer:Zone:F3 N1 APARTMENT 11.38 0.02 16-MAY-15:00 1761.85 01-JUL-19:45
Heating:EnergyTransfer:Zone:F3 N1 APARTMENT 2.27 0.00 01-JAN-18:15 1742.10 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F3 N1 APARTMENT 9.10 0.00 01-JAN-00:15 1761.85 01-JUL-19:45
EnergyTransfer:Zone:F3 N2 APARTMENT 11.39 0.00 05-JUN-20:00 1745.05 01-JUL-19:45
Heating:EnergyTransfer:Zone:F3 N2 APARTMENT 2.28 0.00 01-JAN-18:15 1739.67 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F3 N2 APARTMENT 9.12 0.00 01-JAN-00:15 1745.05 01-JUL-19:45
EnergyTransfer:Zone:F3 S1 APARTMENT 17.61 0.01 26-AUG-11:15 2524.00 05-OCT-13:00
Heating:EnergyTransfer:Zone:F3 S1 APARTMENT 0.78 0.00 01-JAN-02:45 1026.09 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F3 S1 APARTMENT 16.83 0.00 01-JAN-00:15 2524.00 05-OCT-13:00
EnergyTransfer:Zone:F3 S2 APARTMENT 17.67 0.10 06-MAR-08:15 2536.02 05-OCT-13:00
Heating:EnergyTransfer:Zone:F3 S2 APARTMENT 0.78 0.00 01-JAN-09:30 1024.83 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F3 S2 APARTMENT 16.89 0.00 01-JAN-00:15 2536.02 05-OCT-13:00
EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F3 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F4 SW APARTMENT 21.68 0.00 03-SEP-03:15 3573.61 30-SEP-16:30
Heating:EnergyTransfer:Zone:F4 SW APARTMENT 3.79 0.00 01-JAN-13:15 2201.17 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F4 SW APARTMENT 17.89 0.00 01-JAN-00:15 3573.61 30-SEP-16:30
EnergyTransfer:Zone:F4 NW APARTMENT 18.54 0.01 26-MAR-13:15 3292.67 08-JUL-19:15
Heating:EnergyTransfer:Zone:F4 NW APARTMENT 7.23 0.00 20-JAN-19:00 2490.98 28-DEC-10:00
Cooling:EnergyTransfer:Zone:F4 NW APARTMENT 11.31 0.00 01-JAN-00:15 3292.67 08-JUL-19:15
EnergyTransfer:Zone:F4 SE APARTMENT 22.05 0.05 16-OCT-00:30 3257.90 28-SEP-14:15
Heating:EnergyTransfer:Zone:F4 SE APARTMENT 3.72 0.00 01-JAN-13:15 2205.01 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F4 SE APARTMENT 18.33 0.00 01-JAN-00:15 3257.90 28-SEP-14:15
EnergyTransfer:Zone:F4 NE APARTMENT 18.66 0.04 30-OCT-19:00 2509.87 01-JUL-19:45
Heating:EnergyTransfer:Zone:F4 NE APARTMENT 6.99 0.00 20-JAN-10:00 2321.00 04-JAN-05:00
Cooling:EnergyTransfer:Zone:F4 NE APARTMENT 11.67 0.00 01-JAN-00:15 2509.87 01-JUL-19:45
EnergyTransfer:Zone:F4 N1 APARTMENT 11.69 0.02 23-APR-15:30 1964.95 03-MAR-13:45
Heating:EnergyTransfer:Zone:F4 N1 APARTMENT 2.41 0.00 01-JAN-18:15 1964.95 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F4 N1 APARTMENT 9.29 0.00 01-JAN-00:15 1781.00 08-JUL-19:30
EnergyTransfer:Zone:F4 N2 APARTMENT 11.71 0.02 30-SEP-09:45 1961.19 03-MAR-13:45
Heating:EnergyTransfer:Zone:F4 N2 APARTMENT 2.41 0.00 01-JAN-18:15 1961.19 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F4 N2 APARTMENT 9.30 0.00 01-JAN-00:15 1764.28 08-JUL-19:30
EnergyTransfer:Zone:F4 S1 APARTMENT 17.90 0.06 18-JAN-13:30 2541.79 05-OCT-13:00
Heating:EnergyTransfer:Zone:F4 S1 APARTMENT 0.85 0.00 01-JAN-02:45 1103.13 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F4 S1 APARTMENT 17.06 0.00 01-JAN-00:15 2541.79 05-OCT-13:00
EnergyTransfer:Zone:F4 S2 APARTMENT 17.94 0.20 18-JAN-12:00 2551.93 05-OCT-13:00
Heating:EnergyTransfer:Zone:F4 S2 APARTMENT 0.85 0.00 01-JAN-02:45 1102.83 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F4 S2 APARTMENT 17.09 0.00 01-JAN-00:15 2551.93 05-OCT-13:00
EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F4 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M SW APARTMENT 21.94 0.01 04-APR-16:00 3613.43 05-AUG-16:45
Heating:EnergyTransfer:Zone:M SW APARTMENT 4.04 0.00 01-JAN-13:15 2313.72 28-DEC-08:15
Cooling:EnergyTransfer:Zone:M SW APARTMENT 17.90 0.00 01-JAN-00:15 3613.43 05-AUG-16:45
EnergyTransfer:Zone:M NW APARTMENT 18.96 0.01 29-OCT-04:45 3342.57 08-JUL-19:15
Heating:EnergyTransfer:Zone:M NW APARTMENT 7.52 0.00 18-JAN-15:00 2628.97 28-DEC-10:00
Cooling:EnergyTransfer:Zone:M NW APARTMENT 11.44 0.00 01-JAN-00:15 3342.57 08-JUL-19:15
EnergyTransfer:Zone:M SE APARTMENT 22.27 0.02 03-APR-19:15 3297.21 28-SEP-14:15
Heating:EnergyTransfer:Zone:M SE APARTMENT 3.97 0.00 01-JAN-13:15 2319.55 28-DEC-08:15
Cooling:EnergyTransfer:Zone:M SE APARTMENT 18.30 0.00 01-JAN-00:15 3297.21 28-SEP-14:15
EnergyTransfer:Zone:M NE APARTMENT 19.06 0.03 12-MAY-14:15 2578.50 01-JUL-19:45
Heating:EnergyTransfer:Zone:M NE APARTMENT 7.27 0.00 18-JAN-15:00 2467.06 03-MAR-13:45
Cooling:EnergyTransfer:Zone:M NE APARTMENT 11.79 0.00 01-JAN-00:15 2578.50 01-JUL-19:45
EnergyTransfer:Zone:M N1 APARTMENT 11.98 0.01 13-MAY-14:45 2149.60 03-MAR-13:45
Heating:EnergyTransfer:Zone:M N1 APARTMENT 2.49 0.00 01-JAN-18:15 2149.60 03-MAR-13:45
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 9.49 0.00 01-JAN-00:15 1826.31 08-JUL-19:30
EnergyTransfer:Zone:M N2 APARTMENT 12.00 0.07 24-JUL-08:15 2145.69 03-MAR-13:45
Heating:EnergyTransfer:Zone:M N2 APARTMENT 2.49 0.00 01-JAN-18:15 2145.69 03-MAR-13:45
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 9.51 0.00 01-JAN-00:15 1809.63 08-JUL-19:30
EnergyTransfer:Zone:M S1 APARTMENT 18.11 0.11 15-OCT-13:15 2573.22 05-OCT-13:00
Heating:EnergyTransfer:Zone:M S1 APARTMENT 0.91 0.00 01-JAN-02:45 1161.70 28-DEC-08:15
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 17.20 0.00 01-JAN-00:15 2573.22 05-OCT-13:00
EnergyTransfer:Zone:M S2 APARTMENT 18.13 0.03 02-JAN-12:00 2583.08 05-OCT-13:00
Heating:EnergyTransfer:Zone:M S2 APARTMENT 0.91 0.00 01-JAN-02:45 1161.59 28-DEC-08:15
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 17.22 0.00 01-JAN-00:15 2583.08 05-OCT-13:00
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F6 SW APARTMENT 21.65 0.01 08-NOV-03:15 3589.57 05-AUG-17:00
Heating:EnergyTransfer:Zone:F6 SW APARTMENT 4.61 0.00 01-JAN-13:15 2462.14 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F6 SW APARTMENT 17.04 0.00 01-JAN-00:15 3589.57 05-AUG-17:00
EnergyTransfer:Zone:F6 NW APARTMENT 19.26 0.01 18-MAY-23:00 3325.47 08-JUL-19:15
Heating:EnergyTransfer:Zone:F6 NW APARTMENT 8.35 0.00 20-JAN-19:00 2799.03 28-DEC-10:00
Cooling:EnergyTransfer:Zone:F6 NW APARTMENT 10.91 0.00 01-JAN-00:15 3325.47 08-JUL-19:15
EnergyTransfer:Zone:F6 SE APARTMENT 21.95 0.03 22-OCT-20:45 3276.68 06-AUG-14:00
Heating:EnergyTransfer:Zone:F6 SE APARTMENT 4.54 0.00 01-JAN-13:15 2468.67 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F6 SE APARTMENT 17.41 0.00 01-JAN-00:15 3276.68 06-AUG-14:00
EnergyTransfer:Zone:F6 NE APARTMENT 19.30 0.01 28-OCT-22:45 2713.21 03-MAR-13:45
Heating:EnergyTransfer:Zone:F6 NE APARTMENT 8.06 0.00 20-JAN-10:00 2713.21 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F6 NE APARTMENT 11.24 0.00 01-JAN-00:15 2581.26 01-JUL-19:45
EnergyTransfer:Zone:F6 N1 APARTMENT 11.89 0.01 05-JUN-20:45 2399.37 03-MAR-13:45
Heating:EnergyTransfer:Zone:F6 N1 APARTMENT 2.94 0.00 03-JAN-17:15 2399.37 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F6 N1 APARTMENT 8.95 0.00 01-JAN-00:15 1799.29 08-JUL-19:30
EnergyTransfer:Zone:F6 N2 APARTMENT 11.90 0.03 16-NOV-15:00 2395.66 03-MAR-13:45
Heating:EnergyTransfer:Zone:F6 N2 APARTMENT 2.94 0.00 03-JAN-17:15 2395.66 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F6 N2 APARTMENT 8.96 0.00 01-JAN-00:15 1782.29 08-JUL-19:30
EnergyTransfer:Zone:F6 S1 APARTMENT 17.44 0.02 28-JAN-21:30 2542.51 05-OCT-13:15
Heating:EnergyTransfer:Zone:F6 S1 APARTMENT 1.12 0.00 01-JAN-09:45 1261.38 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F6 S1 APARTMENT 16.32 0.00 01-JAN-00:15 2542.51 05-OCT-13:15
EnergyTransfer:Zone:F6 S2 APARTMENT 17.45 0.01 09-MAR-15:15 2553.65 05-OCT-13:00
Heating:EnergyTransfer:Zone:F6 S2 APARTMENT 1.12 0.00 01-JAN-03:00 1261.32 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F6 S2 APARTMENT 16.33 0.00 01-JAN-00:15 2553.65 05-OCT-13:00
EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F6 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F7 SW APARTMENT 21.59 0.01 20-APR-11:15 3588.88 05-AUG-17:00
Heating:EnergyTransfer:Zone:F7 SW APARTMENT 5.09 0.00 01-JAN-13:15 2581.11 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F7 SW APARTMENT 16.50 0.00 01-JAN-00:15 3588.88 05-AUG-17:00
EnergyTransfer:Zone:F7 NW APARTMENT 19.61 0.00 15-OCT-04:45 3328.24 08-JUL-19:15
Heating:EnergyTransfer:Zone:F7 NW APARTMENT 8.99 0.00 20-JAN-19:00 2936.35 28-DEC-10:00
Cooling:EnergyTransfer:Zone:F7 NW APARTMENT 10.62 0.00 01-JAN-00:15 3328.24 08-JUL-19:15
EnergyTransfer:Zone:F7 SE APARTMENT 21.87 0.01 11-MAY-20:30 3281.23 06-AUG-14:00
Heating:EnergyTransfer:Zone:F7 SE APARTMENT 5.01 0.00 01-JAN-13:30 2588.11 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F7 SE APARTMENT 16.86 0.00 01-JAN-00:15 3281.23 06-AUG-14:00
EnergyTransfer:Zone:F7 NE APARTMENT 19.60 0.02 13-JUN-11:00 2917.53 03-MAR-13:45
Heating:EnergyTransfer:Zone:F7 NE APARTMENT 8.67 0.00 20-JAN-10:00 2917.53 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F7 NE APARTMENT 10.93 0.00 01-JAN-00:15 2593.76 01-JUL-19:45
EnergyTransfer:Zone:F7 N1 APARTMENT 11.93 0.00 12-SEP-15:15 2610.88 03-MAR-13:45
Heating:EnergyTransfer:Zone:F7 N1 APARTMENT 3.28 0.00 03-JAN-17:15 2610.88 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F7 N1 APARTMENT 8.65 0.00 01-JAN-00:15 1792.49 08-JUL-19:30
EnergyTransfer:Zone:F7 N2 APARTMENT 11.94 0.01 01-MAR-11:45 2606.94 03-MAR-13:45
Heating:EnergyTransfer:Zone:F7 N2 APARTMENT 3.28 0.00 03-JAN-17:15 2606.94 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F7 N2 APARTMENT 8.66 0.00 01-JAN-00:15 1775.60 08-JUL-19:30
EnergyTransfer:Zone:F7 S1 APARTMENT 17.04 0.02 22-NOV-21:30 2533.83 05-OCT-13:15
Heating:EnergyTransfer:Zone:F7 S1 APARTMENT 1.30 0.00 01-JAN-03:00 1370.84 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F7 S1 APARTMENT 15.75 0.00 01-JAN-00:15 2533.83 05-OCT-13:15
EnergyTransfer:Zone:F7 S2 APARTMENT 17.07 0.05 20-FEB-04:30 2543.59 05-OCT-13:15
Heating:EnergyTransfer:Zone:F7 S2 APARTMENT 1.30 0.00 01-JAN-03:00 1361.68 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F7 S2 APARTMENT 15.77 0.00 01-JAN-00:15 2543.59 05-OCT-13:15
EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F7 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F8 SW APARTMENT 21.66 0.00 12-JUN-06:45 3599.18 05-AUG-17:15
Heating:EnergyTransfer:Zone:F8 SW APARTMENT 5.59 0.00 01-JAN-13:30 2694.08 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F8 SW APARTMENT 16.08 0.00 01-JAN-00:15 3599.18 05-AUG-17:15
EnergyTransfer:Zone:F8 NW APARTMENT 20.05 0.01 10-MAY-03:30 3340.15 08-JUL-19:15
Heating:EnergyTransfer:Zone:F8 NW APARTMENT 9.62 0.00 20-JAN-19:00 3074.16 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F8 NW APARTMENT 10.44 0.00 01-JAN-00:15 3340.15 08-JUL-19:15
EnergyTransfer:Zone:F8 SE APARTMENT 21.92 0.01 06-NOV-16:45 3296.21 06-AUG-14:00
Heating:EnergyTransfer:Zone:F8 SE APARTMENT 5.49 0.00 01-JAN-13:30 2701.48 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F8 SE APARTMENT 16.43 0.00 01-JAN-00:15 3296.21 06-AUG-14:00
EnergyTransfer:Zone:F8 NE APARTMENT 20.00 0.01 25-OCT-18:00 3101.99 03-MAR-13:45
Heating:EnergyTransfer:Zone:F8 NE APARTMENT 9.27 0.00 20-JAN-10:00 3101.99 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F8 NE APARTMENT 10.73 0.00 01-JAN-00:15 2601.81 01-JUL-19:45
EnergyTransfer:Zone:F8 N1 APARTMENT 12.10 0.17 10-FEB-00:30 2800.54 03-MAR-13:45
Heating:EnergyTransfer:Zone:F8 N1 APARTMENT 3.64 0.00 03-JAN-17:15 2800.54 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F8 N1 APARTMENT 8.46 0.00 01-JAN-00:15 1799.88 08-JUL-19:30
EnergyTransfer:Zone:F8 N2 APARTMENT 12.11 0.01 04-MAR-12:15 2797.15 03-MAR-13:45
Heating:EnergyTransfer:Zone:F8 N2 APARTMENT 3.64 0.00 03-JAN-17:15 2797.15 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F8 N2 APARTMENT 8.47 0.00 01-JAN-00:15 1783.13 08-JUL-19:30
EnergyTransfer:Zone:F8 S1 APARTMENT 16.78 0.03 13-MAR-05:15 2522.82 31-AUG-13:45
Heating:EnergyTransfer:Zone:F8 S1 APARTMENT 1.50 0.00 01-JAN-03:00 1533.37 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F8 S1 APARTMENT 15.28 0.00 01-JAN-00:15 2522.82 31-AUG-13:45
EnergyTransfer:Zone:F8 S2 APARTMENT 16.81 0.03 09-MAR-13:30 2533.45 31-AUG-13:45
Heating:EnergyTransfer:Zone:F8 S2 APARTMENT 1.51 0.00 01-JAN-03:00 1529.13 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F8 S2 APARTMENT 15.30 0.00 01-JAN-00:15 2533.45 31-AUG-13:45
EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F8 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:F9 SW APARTMENT 22.34 0.01 23-MAR-19:45 3721.00 05-AUG-17:15
Heating:EnergyTransfer:Zone:F9 SW APARTMENT 6.61 0.00 01-JAN-13:30 2880.86 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F9 SW APARTMENT 15.73 0.00 01-JAN-00:15 3721.00 05-AUG-17:15
EnergyTransfer:Zone:F9 NW APARTMENT 21.36 0.01 16-SEP-04:00 3436.72 08-JUL-19:15
Heating:EnergyTransfer:Zone:F9 NW APARTMENT 10.90 0.00 26-JAN-16:30 3274.66 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F9 NW APARTMENT 10.47 0.00 01-JAN-00:15 3436.72 08-JUL-19:15
EnergyTransfer:Zone:F9 SE APARTMENT 22.49 0.01 08-APR-18:15 3381.12 06-AUG-14:00
Heating:EnergyTransfer:Zone:F9 SE APARTMENT 6.45 0.00 01-JAN-13:30 2888.93 28-DEC-08:15
Cooling:EnergyTransfer:Zone:F9 SE APARTMENT 16.04 0.00 01-JAN-00:15 3381.12 06-AUG-14:00
EnergyTransfer:Zone:F9 NE APARTMENT 21.15 0.03 30-MAY-17:00 3301.20 03-MAR-13:45
Heating:EnergyTransfer:Zone:F9 NE APARTMENT 10.45 0.00 20-JAN-19:00 3301.20 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F9 NE APARTMENT 10.70 0.00 01-JAN-00:15 2651.39 01-JUL-19:45
EnergyTransfer:Zone:F9 N1 APARTMENT 12.86 0.05 21-DEC-20:45 3010.43 03-MAR-13:45
Heating:EnergyTransfer:Zone:F9 N1 APARTMENT 4.50 0.00 03-JAN-17:30 3010.43 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F9 N1 APARTMENT 8.36 0.00 01-JAN-00:15 1899.28 08-JUL-19:30
EnergyTransfer:Zone:F9 N2 APARTMENT 12.88 0.02 26-AUG-14:45 3007.59 03-MAR-13:45
Heating:EnergyTransfer:Zone:F9 N2 APARTMENT 4.51 0.00 03-JAN-17:30 3007.59 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F9 N2 APARTMENT 8.38 0.00 01-JAN-00:15 1882.59 08-JUL-19:15
EnergyTransfer:Zone:F9 S1 APARTMENT 16.71 0.04 05-FEB-06:00 2583.42 31-AUG-14:00
Heating:EnergyTransfer:Zone:F9 S1 APARTMENT 1.99 0.00 01-JAN-10:00 1735.14 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F9 S1 APARTMENT 14.72 0.00 01-JAN-00:15 2583.42 31-AUG-14:00
EnergyTransfer:Zone:F9 S2 APARTMENT 16.74 0.12 16-NOV-03:30 2594.80 31-AUG-14:00
Heating:EnergyTransfer:Zone:F9 S2 APARTMENT 2.00 0.00 01-JAN-10:00 1731.09 03-MAR-13:45
Cooling:EnergyTransfer:Zone:F9 S2 APARTMENT 14.74 0.00 01-JAN-00:15 2594.80 31-AUG-14:00
EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:F9 CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:T SW APARTMENT 29.21 0.01 14-MAR-14:00 4637.45 05-AUG-16:45
Heating:EnergyTransfer:Zone:T SW APARTMENT 12.52 0.00 01-JAN-13:30 3591.53 04-JAN-05:00
Cooling:EnergyTransfer:Zone:T SW APARTMENT 16.69 0.00 01-JAN-00:15 4637.45 05-AUG-16:45
EnergyTransfer:Zone:T NW APARTMENT 27.91 0.13 06-FEB-18:45 4213.87 12-JUL-17:45
Heating:EnergyTransfer:Zone:T NW APARTMENT 16.36 0.00 26-JAN-16:15 3743.19 28-DEC-10:00
Cooling:EnergyTransfer:Zone:T NW APARTMENT 11.55 0.00 01-JAN-00:15 4213.87 12-JUL-17:45
EnergyTransfer:Zone:T SE APARTMENT 28.62 0.01 14-OCT-20:00 4129.23 01-OCT-12:45
Heating:EnergyTransfer:Zone:T SE APARTMENT 12.09 0.00 01-JAN-13:30 3598.70 04-JAN-05:00
Cooling:EnergyTransfer:Zone:T SE APARTMENT 16.52 0.00 01-JAN-00:15 4129.23 01-OCT-12:45
EnergyTransfer:Zone:T NE APARTMENT 26.80 0.03 24-SEP-05:00 3659.05 04-JAN-05:00
Heating:EnergyTransfer:Zone:T NE APARTMENT 15.53 0.00 24-JAN-10:45 3659.05 04-JAN-05:00
Cooling:EnergyTransfer:Zone:T NE APARTMENT 11.27 0.00 01-JAN-00:15 3272.15 12-JUL-17:15
EnergyTransfer:Zone:T N1 APARTMENT 17.25 0.00 10-MAR-21:30 3074.49 03-MAR-13:45
Heating:EnergyTransfer:Zone:T N1 APARTMENT 8.67 0.00 09-JAN-13:45 3074.49 03-MAR-13:45
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 8.59 0.00 01-JAN-00:15 2530.51 01-JUL-19:45
EnergyTransfer:Zone:T N2 APARTMENT 17.26 0.01 03-SEP-23:45 3072.48 03-MAR-13:45
Heating:EnergyTransfer:Zone:T N2 APARTMENT 8.67 0.00 09-JAN-13:45 3072.48 03-MAR-13:45
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 8.59 0.00 01-JAN-00:15 2506.32 01-JUL-19:45
EnergyTransfer:Zone:T S1 APARTMENT 19.79 0.02 01-NOV-18:00 3425.70 28-SEP-14:15
Heating:EnergyTransfer:Zone:T S1 APARTMENT 5.69 0.00 01-JAN-13:00 2249.42 04-JAN-05:00
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 14.10 0.00 01-JAN-00:15 3425.70 28-SEP-14:15
EnergyTransfer:Zone:T S2 APARTMENT 19.82 0.01 03-DEC-14:30 3433.42 28-SEP-14:15
Heating:EnergyTransfer:Zone:T S2 APARTMENT 5.69 0.00 01-JAN-13:00 2249.18 04-JAN-05:00
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 14.13 0.00 01-JAN-00:15 3433.42 28-SEP-14:15
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Plant 1313.59 461.65 19-AUG-01:15 198631.23 28-DEC-08:15
WaterSystems:EnergyTransfer 906.74 461.65 19-AUG-01:15 62516.78 14-FEB-07:30
sub cat:WaterSystems:EnergyTransfer 906.74 461.65 19-AUG-01:15 62516.78 14-FEB-07:30
EnergyTransfer:HVAC 1656.46 0.00 03-MAR-18:45 251657.34 31-JUL-18:00
CoolingCoils:EnergyTransfer 1069.56 0.00 01-JAN-00:15 251657.34 31-JUL-18:00
HeatingCoils:EnergyTransfer 586.90 0.00 10-FEB-15:00 192816.02 04-JAN-05:00
PlantLoopHeatingDemand:HVAC 449.02 0.00 10-FEB-15:00 147871.06 04-JAN-05:00
HeatingCoils:PlantLoopHeatingDemand 449.02 0.00 10-FEB-15:00 147871.06 04-JAN-05:00
Boilers:EnergyTransfer 406.85 0.00 26-JAN-13:45 144930.60 04-JAN-05:15



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 5.096 -10.277 0.000 0.000 3.815 1.087 12.213 23.280 0.000 0.304 0.000 0.000 -11.272 0.000 -7.374 -16.871
G NW APARTMENT 8.076 -6.689 0.000 0.000 3.857 1.087 12.213 11.723 0.000 0.305 0.000 0.000 -11.430 0.000 -6.925 -12.215
OFFICE 3.729 -19.780 0.000 0.000 0.518 29.882 9.495 23.198 0.000 0.233 0.000 0.000 -11.141 0.000 -4.732 -31.403
G NE APARTMENT 7.762 -6.811 0.000 0.000 3.873 1.087 12.213 11.691 0.000 0.305 0.000 0.000 -11.035 0.000 -6.938 -12.147
G N1 APARTMENT 4.182 -5.166 0.000 0.000 3.880 1.087 12.213 3.809 0.000 0.213 0.000 0.000 -7.062 0.000 -4.848 -8.308
G N2 APARTMENT 4.179 -5.176 0.000 0.000 3.881 1.087 12.213 3.806 0.000 0.213 0.000 0.000 -7.058 0.000 -4.850 -8.294
G S1 APARTMENT 1.801 -9.214 0.000 0.000 3.817 1.087 12.213 15.470 0.000 0.211 0.000 0.000 -6.855 0.000 -5.389 -13.140
G S2 APARTMENT 1.705 -9.473 0.000 0.000 3.812 1.087 12.213 15.449 0.000 0.211 0.000 0.000 -6.871 0.000 -5.434 -12.697
F2 SW APARTMENT 3.596 -16.890 0.000 0.000 3.741 1.087 12.213 22.642 0.000 0.415 0.000 0.000 -12.039 0.000 -10.098 -4.666
F2 NW APARTMENT 6.889 -10.527 0.000 0.000 3.805 1.087 12.213 11.263 0.000 0.415 0.000 0.000 -12.092 0.000 -9.563 -3.490
F2 SE APARTMENT 3.043 -18.706 0.000 0.000 3.733 1.087 12.213 22.598 0.000 0.417 0.000 0.000 -11.795 0.000 -10.206 -2.383
F2 NE APARTMENT 6.621 -10.838 0.000 0.000 3.820 1.087 12.213 11.245 0.000 0.416 0.000 0.000 -11.671 0.000 -9.558 -3.333
F2 N1 APARTMENT 2.480 -8.269 0.000 0.000 3.822 1.087 12.213 3.567 0.000 0.282 0.000 0.000 -7.527 0.000 -6.662 -0.993
F2 N2 APARTMENT 2.482 -8.287 0.000 0.000 3.823 1.087 12.213 3.565 0.000 0.282 0.000 0.000 -7.523 0.000 -6.663 -0.978
F2 S1 APARTMENT 0.870 -15.351 0.000 0.000 3.727 1.087 12.213 15.070 0.000 0.280 0.001 0.000 -7.344 0.000 -7.327 -3.223
F2 S2 APARTMENT 0.854 -15.506 0.000 0.000 3.724 1.087 12.213 15.063 0.000 0.280 0.000 0.000 -7.351 0.000 -7.341 -3.022
F3 SW APARTMENT 3.526 -17.889 0.000 0.000 3.732 1.087 12.213 22.403 0.000 0.503 0.001 0.000 -12.249 0.000 -11.574 -1.751
F3 NW APARTMENT 6.841 -11.222 0.000 0.000 3.795 1.087 12.213 11.103 0.000 0.504 0.000 0.000 -12.301 0.000 -11.008 -1.011
F3 SE APARTMENT 3.370 -18.510 0.000 0.000 3.736 1.087 12.213 22.425 0.000 0.506 0.000 0.000 -11.912 0.000 -11.613 -1.300
F3 NE APARTMENT 6.608 -11.568 0.000 0.000 3.810 1.087 12.213 11.097 0.000 0.505 0.000 0.000 -11.876 0.000 -11.000 -0.874
F3 N1 APARTMENT 2.275 -9.104 0.000 0.000 3.806 1.087 12.213 3.494 0.000 0.347 1.208 0.000 -7.680 0.000 -7.645 -0.000
F3 N2 APARTMENT 2.276 -9.116 0.000 0.000 3.807 1.087 12.213 3.492 0.000 0.347 1.218 0.000 -7.677 0.000 -7.645 -0.000
F3 S1 APARTMENT 0.780 -16.828 0.000 0.000 3.708 1.087 12.213 14.915 0.000 0.344 0.000 0.000 -7.499 0.000 -8.334 -0.385
F3 S2 APARTMENT 0.780 -16.886 0.000 0.000 3.707 1.087 12.213 14.911 0.000 0.345 0.001 0.000 -7.500 0.000 -8.340 -0.316
F4 SW APARTMENT 3.792 -17.891 0.000 0.000 3.732 1.087 12.213 22.265 0.000 0.553 0.001 0.000 -12.341 0.000 -12.528 -0.882
F4 NW APARTMENT 7.230 -11.307 0.000 0.000 3.794 1.087 12.213 11.017 0.000 0.554 0.000 0.000 -12.404 0.000 -11.945 -0.239
F4 SE APARTMENT 3.719 -18.327 0.000 0.000 3.739 1.087 12.213 22.305 0.000 0.556 0.000 0.000 -11.986 0.000 -12.553 -0.752
F4 NE APARTMENT 6.993 -11.667 0.000 0.000 3.809 1.087 12.213 11.020 0.000 0.554 0.000 0.000 -11.977 0.000 -11.933 -0.098
F4 N1 APARTMENT 2.406 -9.288 0.000 0.000 3.802 1.087 12.213 3.459 0.000 0.379 1.932 0.000 -7.757 0.000 -8.231 -0.000
F4 N2 APARTMENT 2.409 -9.303 0.000 0.000 3.802 1.087 12.213 3.457 0.000 0.379 1.941 0.000 -7.753 0.000 -8.231 -0.000
F4 S1 APARTMENT 0.846 -17.058 0.000 0.000 3.705 1.087 12.213 14.826 0.000 0.377 0.499 0.000 -7.567 0.000 -8.927 -0.000
F4 S2 APARTMENT 0.850 -17.086 0.000 0.000 3.705 1.087 12.213 14.824 0.000 0.377 0.528 0.000 -7.566 0.000 -8.931 -0.000
M SW APARTMENT 4.037 -17.901 0.000 0.000 3.734 1.087 12.213 22.156 0.000 0.593 0.001 0.000 -12.414 0.000 -13.428 -0.075
M NW APARTMENT 7.523 -11.436 0.000 0.000 3.795 1.087 12.213 10.951 0.000 0.594 0.573 0.000 -12.485 0.000 -12.814 -0.001
M SE APARTMENT 3.971 -18.301 0.000 0.000 3.741 1.087 12.213 22.203 0.000 0.596 0.001 0.000 -12.055 0.000 -13.452 -0.002
M NE APARTMENT 7.270 -11.794 0.000 0.000 3.809 1.087 12.213 10.960 0.000 0.594 0.718 0.000 -12.057 0.000 -12.799 -0.000
M N1 APARTMENT 2.488 -9.492 0.000 0.000 3.800 1.087 12.213 3.433 0.000 0.404 2.684 0.000 -7.816 0.000 -8.801 -0.000
M N2 APARTMENT 2.492 -9.506 0.000 0.000 3.801 1.087 12.213 3.432 0.000 0.404 2.692 0.000 -7.812 0.000 -8.802 -0.000
M S1 APARTMENT 0.909 -17.201 0.000 0.000 3.706 1.087 12.213 14.758 0.000 0.402 1.270 0.000 -7.618 0.000 -9.525 -0.000
M S2 APARTMENT 0.913 -17.221 0.000 0.000 3.706 1.087 12.213 14.756 0.000 0.402 1.289 0.000 -7.616 0.000 -9.529 -0.000
F6 SW APARTMENT 4.611 -17.037 0.000 0.000 3.743 1.087 12.213 22.101 0.000 0.626 0.000 0.000 -12.413 0.000 -14.155 -0.776
F6 NW APARTMENT 8.351 -10.907 0.000 0.000 3.803 1.087 12.213 10.931 0.000 0.627 0.000 0.000 -12.489 0.000 -13.493 -0.123
F6 SE APARTMENT 4.537 -17.411 0.000 0.000 3.750 1.087 12.213 22.154 0.000 0.630 0.001 0.000 -12.055 0.000 -14.184 -0.720
F6 NE APARTMENT 8.060 -11.243 0.000 0.000 3.818 1.087 12.213 10.946 0.000 0.627 0.028 0.000 -12.061 0.000 -13.475 -0.000
F6 N1 APARTMENT 2.936 -8.951 0.000 0.000 3.809 1.087 12.213 3.434 0.000 0.425 2.077 0.000 -7.817 0.000 -9.213 -0.000
F6 N2 APARTMENT 2.935 -8.963 0.000 0.000 3.810 1.087 12.213 3.432 0.000 0.425 2.087 0.000 -7.813 0.000 -9.214 -0.000
F6 S1 APARTMENT 1.117 -16.319 0.000 0.000 3.715 1.087 12.213 14.725 0.000 0.424 0.646 0.000 -7.617 0.000 -9.991 -0.000
F6 S2 APARTMENT 1.120 -16.334 0.000 0.000 3.715 1.087 12.213 14.722 0.000 0.424 0.663 0.000 -7.615 0.000 -9.994 -0.000
F7 SW APARTMENT 5.093 -16.497 0.000 0.000 3.749 1.087 12.213 22.048 0.000 0.655 0.001 0.000 -12.424 0.000 -14.798 -1.125
F7 NW APARTMENT 8.988 -10.619 0.000 0.000 3.810 1.087 12.213 10.908 0.000 0.656 0.000 0.000 -12.503 0.000 -14.098 -0.441
F7 SE APARTMENT 5.009 -16.861 0.000 0.000 3.756 1.087 12.213 22.104 0.000 0.659 0.000 0.000 -12.065 0.000 -14.831 -1.070
F7 NE APARTMENT 8.667 -10.932 0.000 0.000 3.824 1.087 12.213 10.928 0.000 0.656 0.000 0.000 -12.075 0.000 -14.078 -0.289
F7 N1 APARTMENT 3.276 -8.651 0.000 0.000 3.816 1.087 12.213 3.432 0.000 0.444 1.791 0.000 -7.824 0.000 -9.583 -0.000
F7 N2 APARTMENT 3.276 -8.663 0.000 0.000 3.817 1.087 12.213 3.430 0.000 0.443 1.802 0.000 -7.821 0.000 -9.583 -0.001
F7 S1 APARTMENT 1.298 -15.747 0.000 0.000 3.723 1.087 12.213 14.692 0.000 0.442 0.317 0.000 -7.622 0.000 -10.402 -0.001
F7 S2 APARTMENT 1.304 -15.766 0.000 0.000 3.723 1.087 12.213 14.690 0.000 0.443 0.335 0.000 -7.620 0.000 -10.406 -0.000
F8 SW APARTMENT 5.587 -16.076 0.000 0.000 3.756 1.087 12.213 22.002 0.000 0.684 0.000 0.000 -12.432 0.000 -15.391 -1.429
F8 NW APARTMENT 9.617 -10.436 0.000 0.000 3.815 1.087 12.213 10.886 0.000 0.685 0.000 0.000 -12.518 0.000 -14.659 -0.690
F8 SE APARTMENT 5.487 -16.428 0.000 0.000 3.762 1.087 12.213 22.061 0.000 0.688 0.000 0.000 -12.074 0.000 -15.426 -1.370
F8 NE APARTMENT 9.269 -10.732 0.000 0.000 3.829 1.087 12.213 10.911 0.000 0.685 0.000 0.000 -12.090 0.000 -14.636 -0.535
F8 N1 APARTMENT 3.639 -8.458 0.000 0.000 3.822 1.087 12.213 3.429 0.000 0.464 1.568 0.000 -7.832 0.000 -9.931 -0.000
F8 N2 APARTMENT 3.639 -8.472 0.000 0.000 3.823 1.087 12.213 3.427 0.000 0.463 1.580 0.000 -7.828 0.000 -9.931 -0.000
F8 S1 APARTMENT 1.503 -15.277 0.000 0.000 3.730 1.087 12.213 14.665 0.000 0.463 0.027 0.000 -7.625 0.000 -10.785 -0.000
F8 S2 APARTMENT 1.509 -15.297 0.000 0.000 3.730 1.087 12.213 14.662 0.000 0.463 0.046 0.000 -7.623 0.000 -10.789 -0.001
F9 SW APARTMENT 6.606 -15.733 0.000 0.000 3.764 1.087 12.213 21.982 0.000 0.711 0.000 0.000 -12.410 0.000 -15.903 -2.317
F9 NW APARTMENT 10.895 -10.467 0.000 0.000 3.820 1.087 12.213 10.878 0.000 0.711 0.000 0.000 -12.510 0.000 -15.156 -1.470
F9 SE APARTMENT 6.451 -16.041 0.000 0.000 3.770 1.087 12.213 22.044 0.000 0.715 0.000 0.000 -12.053 0.000 -15.945 -2.240
F9 NE APARTMENT 10.453 -10.695 0.000 0.000 3.835 1.087 12.213 10.906 0.000 0.710 0.000 0.000 -12.084 0.000 -15.133 -1.291
F9 N1 APARTMENT 4.503 -8.359 0.000 0.000 3.828 1.087 12.213 3.431 0.000 0.482 0.880 0.000 -7.823 0.000 -10.240 -0.000
F9 N2 APARTMENT 4.506 -8.378 0.000 0.000 3.829 1.087 12.213 3.429 0.000 0.481 0.894 0.000 -7.819 0.000 -10.241 -0.000
F9 S1 APARTMENT 1.990 -14.721 0.000 0.000 3.741 1.087 12.213 14.655 0.000 0.482 0.001 0.000 -7.604 0.000 -11.104 -0.737
F9 S2 APARTMENT 1.996 -14.743 0.000 0.000 3.741 1.087 12.213 14.652 0.000 0.482 0.000 0.000 -7.603 0.000 -11.110 -0.714
T SW APARTMENT 12.524 -16.687 0.000 0.000 3.802 1.087 12.213 21.704 0.000 0.734 0.000 0.000 -11.855 0.000 -16.281 -7.240
T NW APARTMENT 16.361 -11.552 0.000 0.000 3.841 1.087 12.213 10.654 0.000 0.732 0.000 0.000 -12.055 0.000 -15.651 -5.629
T SE APARTMENT 12.094 -16.522 0.000 0.000 3.809 1.087 12.213 21.801 0.000 0.736 0.000 0.000 -11.540 0.000 -16.341 -7.336
T NE APARTMENT 15.529 -11.272 0.000 0.000 3.858 1.087 12.213 10.728 0.000 0.733 0.000 0.000 -11.674 0.000 -15.641 -5.561
T N1 APARTMENT 8.668 -8.586 0.000 0.000 3.849 1.087 12.213 3.355 0.000 0.497 0.000 0.000 -7.536 0.000 -10.589 -2.956
T N2 APARTMENT 8.671 -8.589 0.000 0.000 3.850 1.087 12.213 3.350 0.000 0.497 0.000 0.000 -7.531 0.000 -10.597 -2.951
T S1 APARTMENT 5.688 -14.102 0.000 0.000 3.783 1.087 12.213 14.515 0.000 0.499 0.000 0.000 -7.299 0.000 -11.351 -5.033
T S2 APARTMENT 5.695 -14.129 0.000 0.000 3.783 1.087 12.213 14.510 0.000 0.499 0.000 0.000 -7.295 0.000 -11.358 -5.004
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 5.361 0.000 2.435 33.323 0.000 -2.519 0.000 -55.040 -0.000
F2 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 2.445 0.000 0.033 0.000 0.000 -1.515 0.000 -1.235 -16.167
F3 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 2.398 0.000 0.038 0.000 0.000 -1.573 0.000 -1.507 -15.795
F4 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 2.374 0.000 0.041 0.000 0.000 -1.599 0.000 -1.702 -15.554
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 32.880 0.000 2.346 0.000 0.039 0.000 0.000 -1.635 0.000 -1.923 -31.708
F6 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 2.356 0.000 0.047 0.000 0.000 -1.610 0.000 -1.971 -15.263
F7 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 2.356 0.000 0.051 0.000 0.000 -1.602 0.000 -2.064 -15.180
F8 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 2.353 0.000 0.053 0.000 0.000 -1.601 0.000 -2.155 -15.090
F9 CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 0.000 2.352 0.000 0.053 0.000 0.000 -1.597 0.000 -2.231 -15.017
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 16.440 8.151 2.298 0.000 0.031 0.000 0.000 -1.548 0.000 -2.361 -23.011
Total Facility 391.123 -1025.518 0.000 0.000 299.478 296.560 982.450 1059.056 0.000 41.625 64.625 0.000 -801.334 0.000 -941.374 -366.687


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 30-SEP-16:10 0.00 -2834.06 0.00 0.00 84.76 64.86 588.62 4302.90 0.00 0.00 0.00 0.00 0.00 0.00 -50.97 -2156.11
G NW APARTMENT 14-JUL-18:00 0.00 -2518.15 0.00 0.00 139.98 87.56 588.62 3355.88 0.00 119.47 0.00 0.00 0.00 0.00 0.00 -1773.36
OFFICE 28-SEP-14:15 0.00 -3980.64 0.00 0.00 65.20 2345.88 588.62 3629.88 0.00 20.87 0.00 0.00 0.00 0.00 0.00 -2669.81
G NE APARTMENT 22-JUL-08:30 0.00 -1819.84 0.00 0.00 40.75 12.97 394.37 2849.58 0.00 190.09 0.00 0.00 0.00 0.00 0.00 -1667.92
G N1 APARTMENT 08-JUL-19:30 0.00 -1274.35 0.00 0.00 140.79 103.77 523.87 1037.68 0.00 186.85 0.00 0.00 0.00 0.00 0.00 -718.62
G N2 APARTMENT 08-JUL-19:30 0.00 -1254.04 0.00 0.00 140.80 103.77 523.87 1038.21 0.00 187.04 0.00 0.00 0.00 0.00 0.00 -739.65
G S1 APARTMENT 31-AUG-13:45 0.00 -1917.68 0.00 0.00 40.72 12.97 382.60 3046.93 0.00 115.44 0.00 0.00 0.00 0.00 0.00 -1680.98
G S2 APARTMENT 31-AUG-13:45 0.00 -1989.26 0.00 0.00 40.74 12.97 382.60 3045.83 0.00 116.99 0.00 0.00 0.00 0.00 0.00 -1609.88
F2 SW APARTMENT 30-SEP-16:10 0.00 -3564.61 0.00 0.00 84.76 64.86 588.62 4237.86 0.00 0.00 0.00 0.00 0.00 0.00 -72.18 -1339.31
F2 NW APARTMENT 14-JUL-18:30 0.00 -3207.49 0.00 0.00 140.09 103.77 547.42 3351.57 0.00 173.47 0.00 0.00 0.00 0.00 0.00 -1108.83
F2 SE APARTMENT 28-SEP-14:15 0.00 -3439.78 0.00 0.00 40.69 22.70 400.26 3586.64 0.00 208.29 0.00 0.00 0.00 0.00 0.00 -818.81
F2 NE APARTMENT 13-JUL-10:15 0.00 -2412.00 0.00 0.00 40.75 12.97 412.03 2431.95 0.00 118.45 0.00 0.00 0.00 0.00 0.00 -604.15
F2 N1 APARTMENT 08-JUL-19:30 0.00 -1694.63 0.00 0.00 140.74 103.77 523.87 1009.15 0.00 240.30 0.00 0.00 0.00 0.00 0.00 -323.21
F2 N2 APARTMENT 08-JUL-19:30 0.00 -1677.92 0.00 0.00 140.75 103.77 523.87 1009.51 0.00 240.57 0.00 0.00 0.00 0.00 0.00 -340.55
F2 S1 APARTMENT 31-AUG-13:30 0.00 -2452.59 0.00 0.00 40.75 12.97 382.60 3099.37 0.00 103.02 0.00 0.00 0.00 0.00 0.00 -1186.12
F2 S2 APARTMENT 31-AUG-13:30 0.00 -2479.08 0.00 0.00 40.75 12.97 382.60 3099.00 0.00 103.25 0.00 0.00 0.00 0.00 0.00 -1159.50
F3 SW APARTMENT 30-SEP-16:05 0.00 -3574.92 0.00 0.00 84.76 64.86 588.62 4204.49 0.00 0.00 0.00 0.00 0.00 0.00 -83.94 -1283.86
F3 NW APARTMENT 08-JUL-19:15 0.00 -3253.57 0.00 0.00 141.81 103.77 523.87 2829.76 0.00 451.93 0.00 0.00 0.00 0.00 0.00 -797.57
F3 SE APARTMENT 28-SEP-14:15 0.00 -3254.69 0.00 0.00 40.50 22.70 400.26 3574.77 0.00 210.70 0.00 0.00 0.00 0.00 0.00 -994.25
F3 NE APARTMENT 22-JUN-10:15 0.00 -2479.29 0.00 0.00 40.75 12.97 412.03 2292.83 0.00 291.69 0.00 0.00 0.00 0.00 0.00 -570.99
F3 N1 APARTMENT 01-JUL-19:38 0.00 -1763.39 0.00 0.00 141.81 103.77 523.87 800.12 0.00 502.29 0.00 0.00 0.00 0.00 0.00 -308.47
F3 N2 APARTMENT 01-JUL-19:38 0.00 -1746.53 0.00 0.00 141.81 103.77 523.87 800.34 0.00 501.80 0.00 0.00 0.00 0.00 0.00 -325.06
F3 S1 APARTMENT 05-OCT-13:00 0.00 -2524.09 0.00 0.00 40.75 12.97 388.49 3612.17 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -1530.29
F3 S2 APARTMENT 05-OCT-13:00 0.00 -2536.10 0.00 0.00 40.75 12.97 388.49 3611.95 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -1518.05
F4 SW APARTMENT 30-SEP-16:30 0.00 -3573.78 0.00 0.00 84.76 64.86 588.62 4035.05 0.00 0.00 0.00 0.00 0.00 0.00 -98.11 -1101.40
F4 NW APARTMENT 08-JUL-19:15 0.00 -3291.57 0.00 0.00 141.81 103.77 523.87 2811.57 0.00 490.99 0.00 0.00 0.00 0.00 0.00 -780.44
F4 SE APARTMENT 28-SEP-14:15 0.00 -3258.20 0.00 0.00 40.53 22.70 400.26 3565.80 0.00 221.24 0.00 0.00 0.00 0.00 0.00 -992.33
F4 NE APARTMENT 01-JUL-19:45 0.00 -2509.78 0.00 0.00 141.81 103.77 523.87 897.35 0.00 639.64 203.34 0.00 0.00 0.00 0.00 0.00
F4 N1 APARTMENT 01-JUL-19:38 0.00 -1780.85 0.00 0.00 141.81 103.77 523.87 795.12 0.00 543.68 0.00 0.00 0.00 0.00 0.00 -327.40
F4 N2 APARTMENT 01-JUL-19:38 0.00 -1764.06 0.00 0.00 141.81 103.77 523.87 795.34 0.00 543.15 0.00 0.00 0.00 0.00 0.00 -343.88
F4 S1 APARTMENT 05-OCT-13:00 0.00 -2541.89 0.00 0.00 40.75 12.97 388.49 3611.58 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -1511.90
F4 S2 APARTMENT 05-OCT-13:00 0.00 -2552.03 0.00 0.00 40.75 12.97 388.49 3611.38 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -1501.56
M SW APARTMENT 05-AUG-16:45 0.00 -3618.39 0.00 0.00 83.34 64.86 588.62 3300.72 0.00 383.74 0.00 0.00 0.00 0.00 0.00 -802.88
M NW APARTMENT 08-JUL-19:15 0.00 -3341.52 0.00 0.00 141.81 103.77 523.87 2797.08 0.00 522.20 0.00 0.00 0.00 0.00 0.00 -747.21
M SE APARTMENT 28-SEP-14:15 0.00 -3297.52 0.00 0.00 40.59 22.70 400.26 3558.24 0.00 231.71 0.00 0.00 0.00 0.00 0.00 -955.98
M NE APARTMENT 01-JUL-19:45 0.00 -2578.41 0.00 0.00 141.81 103.77 523.87 893.05 0.00 683.54 232.37 0.00 0.00 0.00 0.00 0.00
M N1 APARTMENT 08-JUL-19:30 0.00 -1825.10 0.00 0.00 140.40 103.77 523.87 984.72 0.00 305.64 0.00 0.00 0.00 0.00 0.00 -233.30
M N2 APARTMENT 08-JUL-19:30 0.00 -1808.43 0.00 0.00 140.41 103.77 523.87 985.08 0.00 305.94 0.00 0.00 0.00 0.00 0.00 -250.64
M S1 APARTMENT 05-OCT-13:00 0.00 -2573.34 0.00 0.00 40.75 12.97 388.49 3611.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -1479.88
M S2 APARTMENT 05-OCT-13:00 0.00 -2583.20 0.00 0.00 40.75 12.97 388.49 3610.82 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -1469.83
F6 SW APARTMENT 05-AUG-17:00 0.00 -3590.00 0.00 0.00 83.08 64.86 588.62 3209.46 0.00 432.56 0.00 0.00 0.00 0.00 0.00 -788.58
F6 NW APARTMENT 08-JUL-19:15 0.00 -3324.43 0.00 0.00 141.81 103.77 523.87 2786.75 0.00 548.13 0.00 0.00 0.00 0.00 0.00 -779.90
F6 SE APARTMENT 06-AUG-14:00 0.00 -3276.58 0.00 0.00 40.75 12.97 382.60 2788.96 0.00 366.90 0.00 0.00 0.00 0.00 0.00 -315.60
F6 NE APARTMENT 01-JUL-19:45 0.00 -2581.18 0.00 0.00 141.81 103.77 523.87 891.22 0.00 719.95 200.56 0.00 0.00 0.00 0.00 0.00
F6 N1 APARTMENT 08-JUL-19:30 0.00 -1798.08 0.00 0.00 140.35 103.77 523.87 980.96 0.00 317.76 0.00 0.00 0.00 0.00 0.00 -268.63
F6 N2 APARTMENT 08-JUL-19:30 0.00 -1781.09 0.00 0.00 140.36 103.77 523.87 981.32 0.00 317.98 0.00 0.00 0.00 0.00 0.00 -286.21
F6 S1 APARTMENT 05-OCT-13:15 0.00 -2542.67 0.00 0.00 40.75 12.97 382.60 3574.12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -1467.78
F6 S2 APARTMENT 05-OCT-13:00 0.00 -2553.78 0.00 0.00 40.75 12.97 388.49 3611.32 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -1499.74
F7 SW APARTMENT 05-AUG-17:00 0.00 -3589.32 0.00 0.00 83.00 64.86 588.62 3202.51 0.00 455.71 0.00 0.00 0.00 0.00 0.00 -805.37
F7 NW APARTMENT 08-JUL-19:15 0.00 -3327.20 0.00 0.00 141.81 103.77 523.87 2777.63 0.00 570.16 0.00 0.00 0.00 0.00 0.00 -790.04
F7 SE APARTMENT 06-AUG-14:00 0.00 -3281.12 0.00 0.00 40.75 12.97 382.60 2782.97 0.00 386.91 0.00 0.00 0.00 0.00 0.00 -325.08
F7 NE APARTMENT 01-JUL-19:38 0.00 -2597.28 0.00 0.00 141.81 103.77 523.87 889.03 0.00 750.40 188.40 0.00 0.00 0.00 0.00 0.00
F7 N1 APARTMENT 08-JUL-19:30 0.00 -1791.28 0.00 0.00 140.33 103.77 523.87 977.42 0.00 327.95 0.00 0.00 0.00 0.00 0.00 -282.06
F7 N2 APARTMENT 08-JUL-19:30 0.00 -1774.40 0.00 0.00 140.33 103.77 523.87 977.79 0.00 328.17 0.00 0.00 0.00 0.00 0.00 -299.53
F7 S1 APARTMENT 05-OCT-13:15 0.00 -2533.99 0.00 0.00 40.75 12.97 382.60 3574.15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -1476.48
F7 S2 APARTMENT 05-OCT-13:15 0.00 -2543.75 0.00 0.00 40.75 12.97 382.60 3573.96 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -1466.53
F8 SW APARTMENT 05-AUG-17:10 0.00 -3601.91 0.00 0.00 138.68 87.56 588.62 3148.81 0.00 421.48 0.00 0.00 0.00 0.00 0.00 -783.23
F8 NW APARTMENT 08-JUL-19:15 0.00 -3339.11 0.00 0.00 141.81 103.77 523.87 2769.38 0.00 589.18 0.00 0.00 0.00 0.00 0.00 -788.90
F8 SE APARTMENT 06-AUG-14:00 0.00 -3296.09 0.00 0.00 40.75 12.97 382.60 2776.66 0.00 404.78 0.00 0.00 0.00 0.00 0.00 -321.68
F8 NE APARTMENT 01-JUL-19:38 0.00 -2605.18 0.00 0.00 141.80 103.77 523.87 886.66 0.00 774.13 174.94 0.00 0.00 0.00 0.00 0.00
F8 N1 APARTMENT 08-JUL-19:30 0.00 -1798.66 0.00 0.00 140.33 103.77 523.87 974.12 0.00 337.39 0.00 0.00 0.00 0.00 0.00 -280.81
F8 N2 APARTMENT 08-JUL-19:30 0.00 -1781.92 0.00 0.00 140.33 103.77 523.87 974.48 0.00 337.60 0.00 0.00 0.00 0.00 0.00 -298.14
F8 S1 APARTMENT 31-AUG-13:45 0.00 -2522.13 0.00 0.00 40.75 12.97 382.60 2964.59 0.00 181.78 0.00 0.00 0.00 0.00 0.00 -1060.56
F8 S2 APARTMENT 31-AUG-13:45 0.00 -2532.75 0.00 0.00 40.75 12.97 382.60 2964.36 0.00 181.58 0.00 0.00 0.00 0.00 0.00 -1049.51
F9 SW APARTMENT 05-AUG-17:10 0.00 -3722.48 0.00 0.00 138.84 87.56 588.62 3141.37 0.00 439.10 0.00 0.00 0.00 0.00 0.00 -673.01
F9 NW APARTMENT 08-JUL-19:15 0.00 -3435.67 0.00 0.00 141.81 103.77 523.87 2758.99 0.00 605.77 0.00 0.00 0.00 0.00 0.00 -698.54
F9 SE APARTMENT 06-AUG-14:00 0.00 -3381.00 0.00 0.00 40.75 12.97 382.60 2769.16 0.00 420.99 0.00 0.00 0.00 0.00 0.00 -245.47
F9 NE APARTMENT 01-JUL-19:38 0.00 -2654.60 0.00 0.00 141.80 103.77 523.87 881.67 0.00 790.29 213.19 0.00 0.00 0.00 0.00 0.00
F9 N1 APARTMENT 08-JUL-19:30 0.00 -1898.02 0.00 0.00 140.47 103.77 523.87 969.44 0.00 351.77 0.00 0.00 0.00 0.00 0.00 -191.30
F9 N2 APARTMENT 08-JUL-19:15 0.00 -1881.42 0.00 0.00 141.81 103.77 523.87 907.49 0.00 514.55 0.00 0.00 0.00 0.00 0.00 -310.07
F9 S1 APARTMENT 31-AUG-14:00 0.00 -2582.52 0.00 0.00 40.75 12.97 382.60 2861.17 0.00 239.73 0.00 0.00 0.00 0.00 0.00 -954.70
F9 S2 APARTMENT 31-AUG-14:00 0.00 -2593.90 0.00 0.00 40.75 12.97 382.60 2860.93 0.00 239.55 0.00 0.00 0.00 0.00 0.00 -942.90
T SW APARTMENT 05-AUG-16:45 0.00 -4640.89 0.00 0.00 84.39 64.86 588.62 3226.20 0.00 497.02 179.80 0.00 0.00 0.00 0.00 0.00
T NW APARTMENT 12-JUL-17:45 0.00 -4214.26 0.00 0.00 135.53 87.56 588.62 3327.59 0.00 550.23 0.00 0.00 0.00 0.00 0.00 -475.26
T SE APARTMENT 01-OCT-12:45 0.00 -4129.38 0.00 0.00 40.60 12.97 388.49 4324.01 0.00 183.86 0.00 0.00 0.00 0.00 0.00 -820.55
T NE APARTMENT 12-JUL-17:20 0.00 -3284.09 0.00 0.00 139.56 87.56 588.62 1042.11 0.00 599.33 826.92 0.00 0.00 0.00 0.00 0.00
T N1 APARTMENT 01-JUL-19:45 0.00 -2530.41 0.00 0.00 141.81 103.77 523.87 769.19 0.00 745.69 246.09 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 01-JUL-19:45 0.00 -2506.23 0.00 0.00 141.81 103.77 523.87 769.76 0.00 745.68 221.33 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 28-SEP-14:15 0.00 -3426.04 0.00 0.00 40.45 22.70 400.26 3230.55 0.00 224.75 0.00 0.00 0.00 0.00 0.00 -492.67
T S2 APARTMENT 28-SEP-14:15 0.00 -3433.76 0.00 0.00 40.45 22.70 400.26 3230.34 0.00 224.76 0.00 0.00 0.00 0.00 0.00 -484.74
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 06-AUG-16:10 0.00 -201404.54 0.00 0.00 6669.08 11327.17 47212.47 132461.68 0.00 31767.24 0.00 0.00 0.00 0.00 0.00 -28033.11


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 04-JAN-08:15 1828.82 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -1121.51 0.00 -750.31 -438.91
G NW APARTMENT 13-JAN-08:30 1907.17 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -1264.46 0.00 -319.48 -805.15
OFFICE 28-DEC-07:50 1724.46 0.00 0.00 0.00 0.00 469.18 294.31 0.00 0.00 0.00 0.00 0.00 -1116.45 0.00 -827.31 -544.18
G NE APARTMENT 04-JAN-08:15 1900.20 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -1116.08 0.00 -750.31 -515.73
G N1 APARTMENT 03-MAR-13:35 1289.45 0.00 0.00 0.00 47.42 12.97 388.49 347.69 0.00 0.00 0.00 0.00 0.00 0.00 -1480.49 -605.53
G N2 APARTMENT 03-MAR-13:35 1288.56 0.00 0.00 0.00 47.42 12.97 388.49 347.63 0.00 0.00 0.00 0.00 0.00 0.00 -1480.49 -604.59
G S1 APARTMENT 07-NOV-09:55 1168.98 0.00 0.00 0.00 45.61 12.97 394.37 0.00 0.00 0.00 0.00 0.00 -94.24 0.00 -1301.91 -225.78
G S2 APARTMENT 28-DEC-08:05 1077.69 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -678.07 0.00 -482.94 -398.59
F2 SW APARTMENT 28-DEC-08:05 1903.01 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -1150.66 0.00 -1151.46 -82.81
F2 NW APARTMENT 28-DEC-10:00 2120.15 0.00 0.00 0.00 47.42 12.97 394.37 0.00 0.00 0.00 0.00 0.00 -882.52 0.00 -1370.67 -321.72
F2 SE APARTMENT 28-DEC-08:05 1846.19 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -1160.01 0.00 -1151.46 -16.63
F2 NE APARTMENT 04-JAN-05:00 2042.14 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 0.00 0.00 -1154.29 0.00 -1132.54 -188.11
F2 N1 APARTMENT 03-MAR-13:40 1881.74 0.00 0.00 0.00 46.69 12.97 388.49 321.47 0.00 0.00 0.00 0.00 0.00 0.00 -1979.49 -671.88
F2 N2 APARTMENT 03-MAR-13:40 1880.69 0.00 0.00 0.00 46.69 12.97 388.49 321.36 0.00 0.00 0.00 0.00 0.00 0.00 -1979.47 -670.73
F2 S1 APARTMENT 07-NOV-10:00 1170.67 0.00 0.00 0.00 42.64 12.97 394.37 0.00 0.00 0.00 146.32 0.00 -137.89 0.00 -1629.08 0.00
F2 S2 APARTMENT 07-NOV-10:00 1110.00 0.00 0.00 0.00 42.52 12.97 394.37 0.00 0.00 0.00 210.94 0.00 -139.14 0.00 -1631.66 0.00
F3 SW APARTMENT 28-DEC-08:05 2055.10 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -1166.92 0.00 -1363.98 -6.11
F3 NW APARTMENT 28-DEC-10:00 2311.46 0.00 0.00 0.00 47.42 12.97 394.37 0.00 0.00 0.00 0.00 0.00 -899.15 0.00 -1623.70 -243.36
F3 SE APARTMENT 28-DEC-08:05 2049.16 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 8.86 0.00 -1175.95 0.00 -1363.98 0.00
F3 NE APARTMENT 04-JAN-05:00 2177.87 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 0.00 0.00 -1170.29 0.00 -1341.55 -98.83
F3 N1 APARTMENT 03-MAR-13:40 2198.03 0.00 0.00 0.00 46.50 12.97 388.49 312.43 0.00 0.00 0.00 0.00 0.00 0.00 -2298.63 -659.79
F3 N2 APARTMENT 03-MAR-13:40 2199.03 0.00 0.00 0.00 46.50 12.97 388.49 312.29 0.00 0.00 0.00 0.00 0.00 0.00 -2298.62 -660.65
F3 S1 APARTMENT 07-NOV-10:00 1755.40 0.00 0.00 0.00 41.70 12.97 394.37 0.00 0.00 0.00 0.00 0.00 -155.14 0.00 -1842.22 -207.08
F3 S2 APARTMENT 07-NOV-10:00 1772.85 0.00 0.00 0.00 41.67 12.97 394.37 0.00 0.00 0.00 0.00 0.00 -155.43 0.00 -1842.38 -224.06
F4 SW APARTMENT 28-DEC-08:05 2201.27 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 18.80 0.00 -1176.60 0.00 -1525.38 0.00
F4 NW APARTMENT 28-DEC-10:00 2490.69 0.00 0.00 0.00 47.42 12.97 394.37 0.00 0.00 0.00 0.00 0.00 -909.29 0.00 -1815.89 -220.28
F4 SE APARTMENT 28-DEC-08:05 2205.11 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 24.67 0.00 -1186.32 0.00 -1525.38 0.00
F4 NE APARTMENT 04-JAN-05:00 2320.73 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 0.00 0.00 -1179.99 0.00 -1500.27 -73.27
F4 N1 APARTMENT 03-MAR-13:40 2407.32 0.00 0.00 0.00 46.53 12.97 388.49 308.37 0.00 0.00 0.00 0.00 0.00 0.00 -2547.62 -616.07
F4 N2 APARTMENT 03-MAR-13:40 2407.01 0.00 0.00 0.00 46.53 12.97 388.49 308.24 0.00 0.00 0.00 0.00 0.00 0.00 -2547.60 -615.64
F4 S1 APARTMENT 03-MAR-13:45 1595.42 0.00 0.00 0.00 41.57 12.97 388.49 2844.71 0.00 0.00 0.00 0.00 0.00 0.00 -2555.87 -2327.29
F4 S2 APARTMENT 03-MAR-13:45 1569.22 0.00 0.00 0.00 41.52 12.97 388.49 2844.10 0.00 0.00 0.00 0.00 0.00 0.00 -2556.76 -2299.53
M SW APARTMENT 28-DEC-08:05 2313.81 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 47.85 0.00 -1184.97 0.00 -1658.60 0.00
M NW APARTMENT 28-DEC-10:00 2628.65 0.00 0.00 0.00 47.42 12.97 394.37 0.00 0.00 0.00 0.00 0.00 -917.47 0.00 -1974.55 -191.39
M SE APARTMENT 28-DEC-08:05 2319.64 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 52.77 0.00 -1195.73 0.00 -1658.60 0.00
M NE APARTMENT 03-MAR-13:40 2499.01 0.00 0.00 0.00 47.31 12.97 388.49 517.06 0.00 0.00 0.00 0.00 0.00 0.00 -2956.51 -508.33
M N1 APARTMENT 03-MAR-13:40 2587.87 0.00 0.00 0.00 46.55 12.97 388.49 305.26 0.00 0.00 0.00 0.00 0.00 0.00 -2757.45 -583.68
M N2 APARTMENT 03-MAR-13:40 2587.80 0.00 0.00 0.00 46.54 12.97 388.49 305.12 0.00 0.00 0.00 0.00 0.00 0.00 -2757.44 -583.47
M S1 APARTMENT 03-MAR-13:45 1784.90 0.00 0.00 0.00 41.74 12.97 388.49 2828.29 0.00 0.00 0.00 0.00 0.00 0.00 -2762.19 -2294.20
M S2 APARTMENT 03-MAR-13:45 1790.06 0.00 0.00 0.00 41.71 12.97 388.49 2827.86 0.00 0.00 0.00 0.00 0.00 0.00 -2762.30 -2298.79
F6 SW APARTMENT 28-DEC-08:05 2462.22 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 18.96 0.00 -1189.53 0.00 -1773.57 0.00
F6 NW APARTMENT 28-DEC-10:00 2798.69 0.00 0.00 0.00 47.42 12.97 394.37 0.00 0.00 0.00 0.00 0.00 -922.19 0.00 -2111.49 -219.77
F6 SE APARTMENT 28-DEC-08:05 2468.76 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 23.84 0.00 -1200.95 0.00 -1773.57 0.00
F6 NE APARTMENT 03-MAR-13:45 2712.23 0.00 0.00 0.00 47.42 12.97 388.49 516.63 0.00 0.00 0.00 0.00 0.00 0.00 -3154.91 -522.83
F6 N1 APARTMENT 03-MAR-13:40 2676.84 0.00 0.00 0.00 46.85 12.97 388.49 306.07 0.00 0.00 0.00 0.00 0.00 0.00 -2941.11 -490.11
F6 N2 APARTMENT 03-MAR-13:40 2676.84 0.00 0.00 0.00 46.85 12.97 388.49 305.92 0.00 0.00 0.00 0.00 0.00 0.00 -2941.10 -489.96
F6 S1 APARTMENT 03-MAR-13:45 1847.35 0.00 0.00 0.00 42.27 12.97 388.49 2820.39 0.00 0.00 0.00 0.00 0.00 0.00 -2945.05 -2166.42
F6 S2 APARTMENT 03-MAR-13:45 1852.22 0.00 0.00 0.00 42.24 12.97 388.49 2820.01 0.00 0.00 0.00 0.00 0.00 0.00 -2945.15 -2170.79
F7 SW APARTMENT 28-DEC-08:05 2581.19 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 6.34 0.00 -1193.87 0.00 -1875.58 0.00
F7 NW APARTMENT 28-DEC-10:00 2935.98 0.00 0.00 0.00 47.42 12.97 394.37 0.00 0.00 0.00 0.00 0.00 -926.66 0.00 -2233.01 -231.07
F7 SE APARTMENT 28-DEC-08:05 2588.19 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 11.30 0.00 -1205.83 0.00 -1875.58 0.00
F7 NE APARTMENT 03-MAR-13:45 2916.51 0.00 0.00 0.00 47.42 12.97 388.49 515.24 0.00 0.00 0.00 0.00 0.00 0.00 -3333.78 -546.86
F7 N1 APARTMENT 03-MAR-13:40 2778.45 0.00 0.00 0.00 47.06 12.97 388.49 306.19 0.00 0.00 0.00 0.00 0.00 0.00 -3106.68 -426.48
F7 N2 APARTMENT 03-MAR-13:40 2778.77 0.00 0.00 0.00 47.05 12.97 388.49 306.03 0.00 0.00 0.00 0.00 0.00 0.00 -3106.69 -426.63
F7 S1 APARTMENT 03-MAR-13:45 1901.61 0.00 0.00 0.00 42.71 12.97 388.49 2813.75 0.00 0.00 0.00 0.00 0.00 0.00 -3109.92 -2049.60
F7 S2 APARTMENT 03-MAR-13:45 1900.33 0.00 0.00 0.00 42.68 12.97 388.49 2813.38 0.00 0.00 0.00 0.00 0.00 0.00 -3110.01 -2047.83
F8 SW APARTMENT 03-MAR-13:40 2889.88 0.00 0.00 0.00 44.42 12.97 388.49 3269.88 0.00 0.00 0.00 0.00 0.00 0.00 -3515.38 -3090.25
F8 NW APARTMENT 03-MAR-13:45 3073.13 0.00 0.00 0.00 47.42 12.97 388.49 787.83 0.00 0.00 0.00 0.00 0.00 0.00 -3497.76 -812.09
F8 SE APARTMENT 03-MAR-13:40 2983.32 0.00 0.00 0.00 44.49 12.97 388.49 2997.40 0.00 0.00 0.00 0.00 0.00 0.00 -3510.83 -2915.85
F8 NE APARTMENT 03-MAR-13:45 3100.95 0.00 0.00 0.00 47.42 12.97 388.49 514.00 0.00 0.00 0.00 0.00 0.00 0.00 -3497.76 -566.07
F8 N1 APARTMENT 03-MAR-13:40 2881.57 0.00 0.00 0.00 47.22 12.97 388.49 306.16 0.00 0.00 0.00 0.00 0.00 0.00 -3258.56 -377.86
F8 N2 APARTMENT 03-MAR-13:40 2881.39 0.00 0.00 0.00 47.22 12.97 388.49 306.02 0.00 0.00 0.00 0.00 0.00 0.00 -3258.57 -377.52
F8 S1 APARTMENT 03-MAR-13:40 2299.93 0.00 0.00 0.00 43.07 12.97 388.49 2808.03 0.00 0.00 0.00 0.00 0.00 0.00 -3294.20 -2258.28
F8 S2 APARTMENT 03-MAR-13:40 2281.40 0.00 0.00 0.00 43.04 12.97 388.49 2807.65 0.00 0.00 0.00 0.00 0.00 0.00 -3295.02 -2238.52
F9 SW APARTMENT 03-MAR-13:40 3104.92 0.00 0.00 0.00 44.84 12.97 388.49 3267.59 0.00 0.00 0.00 0.00 0.00 0.00 -3662.13 -3156.69
F9 NW APARTMENT 03-MAR-13:45 3273.60 0.00 0.00 0.00 47.42 12.97 388.49 787.50 0.00 0.00 0.00 0.00 0.00 0.00 -3650.07 -859.92
F9 SE APARTMENT 03-MAR-13:40 3124.77 0.00 0.00 0.00 44.92 12.97 388.49 2996.64 0.00 0.00 0.00 0.00 0.00 0.00 -3660.10 -2907.69
F9 NE APARTMENT 03-MAR-13:45 3300.13 0.00 0.00 0.00 47.42 12.97 388.49 515.17 0.00 0.00 0.00 0.00 0.00 0.00 -3650.07 -614.10
F9 N1 APARTMENT 03-MAR-13:35 3009.64 0.00 0.00 0.00 47.42 12.97 388.49 307.82 0.00 0.00 0.00 0.00 0.00 0.00 -3399.59 -366.75
F9 N2 APARTMENT 03-MAR-13:35 3007.05 0.00 0.00 0.00 47.42 12.97 388.49 307.70 0.00 0.00 0.00 0.00 0.00 0.00 -3399.56 -364.08
F9 S1 APARTMENT 03-MAR-13:40 2835.13 0.00 0.00 0.00 43.59 12.97 388.49 2805.91 0.00 0.00 0.00 0.00 0.00 0.00 -3422.74 -2663.36
F9 S2 APARTMENT 03-MAR-13:40 2816.95 0.00 0.00 0.00 43.56 12.97 388.49 2805.54 0.00 0.00 0.00 0.00 0.00 0.00 -3423.53 -2643.98
T SW APARTMENT 04-JAN-05:00 3591.10 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 0.00 0.00 -1184.63 0.00 -2095.49 -743.78
T NW APARTMENT 28-DEC-10:00 3742.75 0.00 0.00 0.00 47.42 12.97 394.37 0.00 0.00 0.00 0.00 0.00 -908.91 0.00 -2537.03 -751.58
T SE APARTMENT 04-JAN-05:00 3598.29 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 0.00 0.00 -1197.33 0.00 -2095.49 -738.27
T NE APARTMENT 04-JAN-05:00 3658.67 0.00 0.00 0.00 189.67 19.46 223.68 0.00 0.00 0.00 0.00 0.00 -1172.16 0.00 -2095.49 -823.82
T N1 APARTMENT 03-MAR-13:40 3163.48 0.00 0.00 0.00 47.15 12.97 388.49 304.31 0.00 0.00 0.00 0.00 0.00 0.00 -3532.83 -383.57
T N2 APARTMENT 03-MAR-13:40 3165.44 0.00 0.00 0.00 47.14 12.97 388.49 304.20 0.00 0.00 0.00 0.00 0.00 0.00 -3532.85 -385.39
T S1 APARTMENT 03-MAR-13:40 2434.55 0.00 0.00 0.00 42.19 12.97 388.49 2774.87 0.00 0.00 0.00 0.00 0.00 0.00 -3597.93 -2055.14
T S2 APARTMENT 03-MAR-13:40 2423.98 0.00 0.00 0.00 42.17 12.97 388.49 2774.62 0.00 0.00 0.00 0.00 0.00 0.00 -3598.73 -2043.50
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F2 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F3 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F4 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F6 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F7 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F8 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
F9 CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 03-MAR-13:40 158926.20 0.00 0.00 0.00 3627.78 9104.94 31440.07 141187.32 0.00 0.00 0.00 0.00 0.00 0.00 -229763.77 -114522.53



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Sec1.1A-General Information

Data
Weather File Boise Air Terminal Uo ID USA TMY3 WMO#=726810
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 7836.48
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.50
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
F2 SW APARTMENT 88.25 88.25 0.00 168.00
F2 NW APARTMENT 88.25 88.25 0.00 168.00
F2 SE APARTMENT 88.25 88.25 0.00 168.00
F2 NE APARTMENT 88.25 88.25 0.00 168.00
F2 N1 APARTMENT 88.25 88.25 0.00 168.00
F2 N2 APARTMENT 88.25 88.25 0.00 168.00
F2 S1 APARTMENT 88.25 88.25 0.00 168.00
F2 S2 APARTMENT 88.25 88.25 0.00 168.00
F3 SW APARTMENT 88.25 88.25 0.00 168.00
F3 NW APARTMENT 88.25 88.25 0.00 168.00
F3 SE APARTMENT 88.25 88.25 0.00 168.00
F3 NE APARTMENT 88.25 88.25 0.00 168.00
F3 N1 APARTMENT 88.25 88.25 0.00 168.00
F3 N2 APARTMENT 88.25 88.25 0.00 168.00
F3 S1 APARTMENT 88.25 88.25 0.00 168.00
F3 S2 APARTMENT 88.25 88.25 0.00 168.00
F4 SW APARTMENT 88.25 88.25 0.00 168.00
F4 NW APARTMENT 88.25 88.25 0.00 168.00
F4 SE APARTMENT 88.25 88.25 0.00 168.00
F4 NE APARTMENT 88.25 88.25 0.00 168.00
F4 N1 APARTMENT 88.25 88.25 0.00 168.00
F4 N2 APARTMENT 88.25 88.25 0.00 168.00
F4 S1 APARTMENT 88.25 88.25 0.00 168.00
F4 S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
F6 SW APARTMENT 88.25 88.25 0.00 168.00
F6 NW APARTMENT 88.25 88.25 0.00 168.00
F6 SE APARTMENT 88.25 88.25 0.00 168.00
F6 NE APARTMENT 88.25 88.25 0.00 168.00
F6 N1 APARTMENT 88.25 88.25 0.00 168.00
F6 N2 APARTMENT 88.25 88.25 0.00 168.00
F6 S1 APARTMENT 88.25 88.25 0.00 168.00
F6 S2 APARTMENT 88.25 88.25 0.00 168.00
F7 SW APARTMENT 88.25 88.25 0.00 168.00
F7 NW APARTMENT 88.25 88.25 0.00 168.00
F7 SE APARTMENT 88.25 88.25 0.00 168.00
F7 NE APARTMENT 88.25 88.25 0.00 168.00
F7 N1 APARTMENT 88.25 88.25 0.00 168.00
F7 N2 APARTMENT 88.25 88.25 0.00 168.00
F7 S1 APARTMENT 88.25 88.25 0.00 168.00
F7 S2 APARTMENT 88.25 88.25 0.00 168.00
F8 SW APARTMENT 88.25 88.25 0.00 168.00
F8 NW APARTMENT 88.25 88.25 0.00 168.00
F8 SE APARTMENT 88.25 88.25 0.00 168.00
F8 NE APARTMENT 88.25 88.25 0.00 168.00
F8 N1 APARTMENT 88.25 88.25 0.00 168.00
F8 N2 APARTMENT 88.25 88.25 0.00 168.00
F8 S1 APARTMENT 88.25 88.25 0.00 168.00
F8 S2 APARTMENT 88.25 88.25 0.00 168.00
F9 SW APARTMENT 88.25 88.25 0.00 168.00
F9 NW APARTMENT 88.25 88.25 0.00 168.00
F9 SE APARTMENT 88.25 88.25 0.00 168.00
F9 NE APARTMENT 88.25 88.25 0.00 168.00
F9 N1 APARTMENT 88.25 88.25 0.00 168.00
F9 N2 APARTMENT 88.25 88.25 0.00 168.00
F9 S1 APARTMENT 88.25 88.25 0.00 168.00
F9 S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
G CORRIDOR 77.66 0.00 77.66 0.00
F2 CORRIDOR 77.66 0.00 77.66 0.00
F3 CORRIDOR 77.66 0.00 77.66 0.00
F4 CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
F6 CORRIDOR 77.66 0.00 77.66 0.00
F7 CORRIDOR 77.66 0.00 77.66 0.00
F8 CORRIDOR 77.66 0.00 77.66 0.00
F9 CORRIDOR 77.66 0.00 77.66 0.00
T CORRIDOR 77.66 0.00 77.66 0.00
Totals 7836.48 7059.89 776.58  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 133.00
Number of hours cooling loads not met 179.25
Number of hours not met 312.25


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 296.56 13120.46 0.00 0.00 0.00 0.00
Exterior Lighting 162.61 0.00 0.00 0.00 0.00 0.00
Space Heating 159.58 0.00 544.55 187866.75 0.00 0.00
Space Cooling 353.52 70644.80 0.00 0.00 0.00 0.00
Pumps 61.16 1965.77 0.00 0.00 0.00 0.00
Heat Rejection 12.51 2475.14 0.00 0.00 0.00 0.00
Fans-Interior 750.51 23798.64 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 0.00 0.00 1165.01 80520.40 0.00 0.00
Receptacle Equipment 1137.32 57042.02 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 2969.94   1709.56   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 1137.32 2969.94
Natural Gas 0.00 1709.56
Additional 0.00 0.00
Total 1137.32 4679.50


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 37.84
Space Heating 20.36
Space Cooling 45.11
Fans-Interior 95.77
Service Water Heating 0.00
Receptacle Equipment 145.13
Miscellaneous 34.77
Subtotal 378.99


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 69.49
Service Water Heating 148.66
Miscellaneous 0.00
Subtotal 218.15


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 6.34
Space Heating 15.05
Space Cooling 7.55
Fans-Interior 16.04
Service Water Heating 24.90
Receptacle Equipment 24.30
Miscellaneous 5.82



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.266307
G NW APARTMENT DIRECT AIR 0.245974
OFFICE DIRECT AIR 0.385195
G NE APARTMENT DIRECT AIR 0.178831
G N1 APARTMENT DIRECT AIR 0.120314
G N2 APARTMENT DIRECT AIR 0.118360
G S1 APARTMENT DIRECT AIR 0.164237
G S2 APARTMENT DIRECT AIR 0.170995
F2 SW APARTMENT DIRECT AIR 0.340752
F2 NW APARTMENT DIRECT AIR 0.310262
F2 SE APARTMENT DIRECT AIR 0.327454
F2 NE APARTMENT DIRECT AIR 0.238457
F2 N1 APARTMENT DIRECT AIR 0.159432
F2 N2 APARTMENT DIRECT AIR 0.157864
F2 S1 APARTMENT DIRECT AIR 0.214707
F2 S2 APARTMENT DIRECT AIR 0.217214
F3 SW APARTMENT DIRECT AIR 0.343432
F3 NW APARTMENT DIRECT AIR 0.313937
F3 SE APARTMENT DIRECT AIR 0.310405
F3 NE APARTMENT DIRECT AIR 0.243881
F3 N1 APARTMENT DIRECT AIR 0.163563
F3 N2 APARTMENT DIRECT AIR 0.162001
F3 S1 APARTMENT DIRECT AIR 0.219865
F3 S2 APARTMENT DIRECT AIR 0.221042
F4 SW APARTMENT DIRECT AIR 0.346018
F4 NW APARTMENT DIRECT AIR 0.316536
F4 SE APARTMENT DIRECT AIR 0.312031
F4 NE APARTMENT DIRECT AIR 0.246639
F4 N1 APARTMENT DIRECT AIR 0.165741
F4 N2 APARTMENT DIRECT AIR 0.164183
F4 S1 APARTMENT DIRECT AIR 0.222651
F4 S2 APARTMENT DIRECT AIR 0.223639
M SW APARTMENT DIRECT AIR 0.350310
M NW APARTMENT DIRECT AIR 0.320861
M SE APARTMENT DIRECT AIR 0.317028
M NE APARTMENT DIRECT AIR 0.251089
M N1 APARTMENT DIRECT AIR 0.169545
M N2 APARTMENT DIRECT AIR 0.167992
M S1 APARTMENT DIRECT AIR 0.226969
M S2 APARTMENT DIRECT AIR 0.227929
F6 SW APARTMENT DIRECT AIR 0.348302
F6 NW APARTMENT DIRECT AIR 0.318735
F6 SE APARTMENT DIRECT AIR 0.315863
F6 NE APARTMENT DIRECT AIR 0.249205
F6 N1 APARTMENT DIRECT AIR 0.167288
F6 N2 APARTMENT DIRECT AIR 0.165746
F6 S1 APARTMENT DIRECT AIR 0.225085
F6 S2 APARTMENT DIRECT AIR 0.226041
F7 SW APARTMENT DIRECT AIR 0.348372
F7 NW APARTMENT DIRECT AIR 0.318782
F7 SE APARTMENT DIRECT AIR 0.316679
F7 NE APARTMENT DIRECT AIR 0.249425
F7 N1 APARTMENT DIRECT AIR 0.167115
F7 N2 APARTMENT DIRECT AIR 0.165581
F7 S1 APARTMENT DIRECT AIR 0.225227
F7 S2 APARTMENT DIRECT AIR 0.226182
F8 SW APARTMENT DIRECT AIR 0.349698
F8 NW APARTMENT DIRECT AIR 0.320098
F8 SE APARTMENT DIRECT AIR 0.318580
F8 NE APARTMENT DIRECT AIR 0.250791
F8 N1 APARTMENT DIRECT AIR 0.168238
F8 N2 APARTMENT DIRECT AIR 0.166714
F8 S1 APARTMENT DIRECT AIR 0.226545
F8 S2 APARTMENT DIRECT AIR 0.227502
F9 SW APARTMENT DIRECT AIR 0.361483
F9 NW APARTMENT DIRECT AIR 0.331466
F9 SE APARTMENT DIRECT AIR 0.327754
F9 NE APARTMENT DIRECT AIR 0.255699
F9 N1 APARTMENT DIRECT AIR 0.178010
F9 N2 APARTMENT DIRECT AIR 0.176478
F9 S1 APARTMENT DIRECT AIR 0.234054
F9 S2 APARTMENT DIRECT AIR 0.235107
T SW APARTMENT DIRECT AIR 0.446752
T NW APARTMENT DIRECT AIR 0.405202
T SE APARTMENT DIRECT AIR 0.409650
T NE APARTMENT DIRECT AIR 0.319637
T N1 APARTMENT DIRECT AIR 0.240293
T N2 APARTMENT DIRECT AIR 0.240115
T S1 APARTMENT DIRECT AIR 0.326633
T S2 APARTMENT DIRECT AIR 0.327472


Branch

Maximum Flow Rate [m3/s]
AIRLOOP G SW MAIN BRANCH 0.266307
AIRLOOP G NW MAIN BRANCH 0.245974
AIRLOOP OFFICE MAIN BRANCH 0.385195
AIRLOOP G NE MAIN BRANCH 0.178831
AIRLOOP G N1 MAIN BRANCH 0.120314
AIRLOOP G N2 MAIN BRANCH 0.118360
AIRLOOP G S1 MAIN BRANCH 0.164237
AIRLOOP G S2 MAIN BRANCH 0.170995
AIRLOOP F2 SW MAIN BRANCH 0.340752
AIRLOOP F2 NW MAIN BRANCH 0.310262
AIRLOOP F2 SE MAIN BRANCH 0.327454
AIRLOOP F2 NE MAIN BRANCH 0.238457
AIRLOOP F2 N1 MAIN BRANCH 0.159432
AIRLOOP F2 N2 MAIN BRANCH 0.157864
AIRLOOP F2 S1 MAIN BRANCH 0.214707
AIRLOOP F2 S2 MAIN BRANCH 0.217214
AIRLOOP F3 SW MAIN BRANCH 0.343432
AIRLOOP F3 NW MAIN BRANCH 0.313937
AIRLOOP F3 SE MAIN BRANCH 0.310405
AIRLOOP F3 NE MAIN BRANCH 0.243881
AIRLOOP F3 N1 MAIN BRANCH 0.163563
AIRLOOP F3 N2 MAIN BRANCH 0.162001
AIRLOOP F3 S1 MAIN BRANCH 0.219865
AIRLOOP F3 S2 MAIN BRANCH 0.221042
AIRLOOP F4 SW MAIN BRANCH 0.346018
AIRLOOP F4 NW MAIN BRANCH 0.316536
AIRLOOP F4 SE MAIN BRANCH 0.312031
AIRLOOP F4 NE MAIN BRANCH 0.246639
AIRLOOP F4 N1 MAIN BRANCH 0.165741
AIRLOOP F4 N2 MAIN BRANCH 0.164183
AIRLOOP F4 S1 MAIN BRANCH 0.222651
AIRLOOP F4 S2 MAIN BRANCH 0.223639
AIRLOOP M SW MAIN BRANCH 0.350310
AIRLOOP M NW MAIN BRANCH 0.320861
AIRLOOP M SE MAIN BRANCH 0.317028
AIRLOOP M NE MAIN BRANCH 0.251089
AIRLOOP M N1 MAIN BRANCH 0.169545
AIRLOOP M N2 MAIN BRANCH 0.167992
AIRLOOP M S1 MAIN BRANCH 0.226969
AIRLOOP M S2 MAIN BRANCH 0.227929
AIRLOOP F6 SW MAIN BRANCH 0.348302
AIRLOOP F6 NW MAIN BRANCH 0.318735
AIRLOOP F6 SE MAIN BRANCH 0.315863
AIRLOOP F6 NE MAIN BRANCH 0.249205
AIRLOOP F6 N1 MAIN BRANCH 0.167288
AIRLOOP F6 N2 MAIN BRANCH 0.165746
AIRLOOP F6 S1 MAIN BRANCH 0.225085
AIRLOOP F6 S2 MAIN BRANCH 0.226041
AIRLOOP F7 SW MAIN BRANCH 0.348372
AIRLOOP F7 NW MAIN BRANCH 0.318782
AIRLOOP F7 SE MAIN BRANCH 0.316679
AIRLOOP F7 NE MAIN BRANCH 0.249425
AIRLOOP F7 N1 MAIN BRANCH 0.167115
AIRLOOP F7 N2 MAIN BRANCH 0.165581
AIRLOOP F7 S1 MAIN BRANCH 0.225227
AIRLOOP F7 S2 MAIN BRANCH 0.226182
AIRLOOP F8 SW MAIN BRANCH 0.349698
AIRLOOP F8 NW MAIN BRANCH 0.320098
AIRLOOP F8 SE MAIN BRANCH 0.318580
AIRLOOP F8 NE MAIN BRANCH 0.250791
AIRLOOP F8 N1 MAIN BRANCH 0.168238
AIRLOOP F8 N2 MAIN BRANCH 0.166714
AIRLOOP F8 S1 MAIN BRANCH 0.226545
AIRLOOP F8 S2 MAIN BRANCH 0.227502
AIRLOOP F9 SW MAIN BRANCH 0.361483
AIRLOOP F9 NW MAIN BRANCH 0.331466
AIRLOOP F9 SE MAIN BRANCH 0.327754
AIRLOOP F9 NE MAIN BRANCH 0.255699
AIRLOOP F9 N1 MAIN BRANCH 0.178010
AIRLOOP F9 N2 MAIN BRANCH 0.176478
AIRLOOP F9 S1 MAIN BRANCH 0.234054
AIRLOOP F9 S2 MAIN BRANCH 0.235107
AIRLOOP T SW MAIN BRANCH 0.446752
AIRLOOP T NW MAIN BRANCH 0.405202
AIRLOOP T SE MAIN BRANCH 0.409650
AIRLOOP T NE MAIN BRANCH 0.319637
AIRLOOP T N1 MAIN BRANCH 0.240293
AIRLOOP T N2 MAIN BRANCH 0.240115
AIRLOOP T S1 MAIN BRANCH 0.326633
AIRLOOP T S2 MAIN BRANCH 0.327472


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
AIRLOOP G SW 0.266307
AIRLOOP G NW 0.245974
AIRLOOP OFFICE 0.385195
AIRLOOP G NE 0.178831
AIRLOOP G N1 0.120314
AIRLOOP G N2 0.118360
AIRLOOP G S1 0.164237
AIRLOOP G S2 0.170995
AIRLOOP F2 SW 0.340752
AIRLOOP F2 NW 0.310262
AIRLOOP F2 SE 0.327454
AIRLOOP F2 NE 0.238457
AIRLOOP F2 N1 0.159432
AIRLOOP F2 N2 0.157864
AIRLOOP F2 S1 0.214707
AIRLOOP F2 S2 0.217214
AIRLOOP F3 SW 0.343432
AIRLOOP F3 NW 0.313937
AIRLOOP F3 SE 0.310405
AIRLOOP F3 NE 0.243881
AIRLOOP F3 N1 0.163563
AIRLOOP F3 N2 0.162001
AIRLOOP F3 S1 0.219865
AIRLOOP F3 S2 0.221042
AIRLOOP F4 SW 0.346018
AIRLOOP F4 NW 0.316536
AIRLOOP F4 SE 0.312031
AIRLOOP F4 NE 0.246639
AIRLOOP F4 N1 0.165741
AIRLOOP F4 N2 0.164183
AIRLOOP F4 S1 0.222651
AIRLOOP F4 S2 0.223639
AIRLOOP M SW 0.350310
AIRLOOP M NW 0.320861
AIRLOOP M SE 0.317028
AIRLOOP M NE 0.251089
AIRLOOP M N1 0.169545
AIRLOOP M N2 0.167992
AIRLOOP M S1 0.226969
AIRLOOP M S2 0.227929
AIRLOOP F6 SW 0.348302
AIRLOOP F6 NW 0.318735
AIRLOOP F6 SE 0.315863
AIRLOOP F6 NE 0.249205
AIRLOOP F6 N1 0.167288
AIRLOOP F6 N2 0.165746
AIRLOOP F6 S1 0.225085
AIRLOOP F6 S2 0.226041
AIRLOOP F7 SW 0.348372
AIRLOOP F7 NW 0.318782
AIRLOOP F7 SE 0.316679
AIRLOOP F7 NE 0.249425
AIRLOOP F7 N1 0.167115
AIRLOOP F7 N2 0.165581
AIRLOOP F7 S1 0.225227
AIRLOOP F7 S2 0.226182
AIRLOOP F8 SW 0.349698
AIRLOOP F8 NW 0.320098
AIRLOOP F8 SE 0.318580
AIRLOOP F8 NE 0.250791
AIRLOOP F8 N1 0.168238
AIRLOOP F8 N2 0.166714
AIRLOOP F8 S1 0.226545
AIRLOOP F8 S2 0.227502
AIRLOOP F9 SW 0.361483
AIRLOOP F9 NW 0.331466
AIRLOOP F9 SE 0.327754
AIRLOOP F9 NE 0.255699
AIRLOOP F9 N1 0.178010
AIRLOOP F9 N2 0.176478
AIRLOOP F9 S1 0.234054
AIRLOOP F9 S2 0.235107
AIRLOOP T SW 0.446752
AIRLOOP T NW 0.405202
AIRLOOP T SE 0.409650
AIRLOOP T NE 0.319637
AIRLOOP T N1 0.240293
AIRLOOP T N2 0.240115
AIRLOOP T S1 0.326633
AIRLOOP T S2 0.327472


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
AIRLOOP G SW OA CONTROLLER 0.266307 0.025952
AIRLOOP G NW OA CONTROLLER 0.245974 0.025952
AIRLOOP OFFICE OA CONTROLLER 0.385195 0.038103
AIRLOOP G NE OA CONTROLLER 0.178831 0.025952
AIRLOOP G N1 OA CONTROLLER 0.120314 0.025952
AIRLOOP G N2 OA CONTROLLER 0.118360 0.025952
AIRLOOP G S1 OA CONTROLLER 0.164237 0.025952
AIRLOOP G S2 OA CONTROLLER 0.170995 0.025952
AIRLOOP F2 SW OA CONTROLLER 0.340752 0.025952
AIRLOOP F2 NW OA CONTROLLER 0.310262 0.025952
AIRLOOP F2 SE OA CONTROLLER 0.327454 0.025952
AIRLOOP F2 NE OA CONTROLLER 0.238457 0.025952
AIRLOOP F2 N1 OA CONTROLLER 0.159432 0.025952
AIRLOOP F2 N2 OA CONTROLLER 0.157864 0.025952
AIRLOOP F2 S1 OA CONTROLLER 0.214707 0.025952
AIRLOOP F2 S2 OA CONTROLLER 0.217214 0.025952
AIRLOOP F3 SW OA CONTROLLER 0.343432 0.025952
AIRLOOP F3 NW OA CONTROLLER 0.313937 0.025952
AIRLOOP F3 SE OA CONTROLLER 0.310405 0.025952
AIRLOOP F3 NE OA CONTROLLER 0.243881 0.025952
AIRLOOP F3 N1 OA CONTROLLER 0.163563 0.025952
AIRLOOP F3 N2 OA CONTROLLER 0.162001 0.025952
AIRLOOP F3 S1 OA CONTROLLER 0.219865 0.025952
AIRLOOP F3 S2 OA CONTROLLER 0.221042 0.025952
AIRLOOP F4 SW OA CONTROLLER 0.346018 0.025952
AIRLOOP F4 NW OA CONTROLLER 0.316536 0.025952
AIRLOOP F4 SE OA CONTROLLER 0.312031 0.025952
AIRLOOP F4 NE OA CONTROLLER 0.246639 0.025952
AIRLOOP F4 N1 OA CONTROLLER 0.165741 0.025952
AIRLOOP F4 N2 OA CONTROLLER 0.164183 0.025952
AIRLOOP F4 S1 OA CONTROLLER 0.222651 0.025952
AIRLOOP F4 S2 OA CONTROLLER 0.223639 0.025952
AIRLOOP M SW OA CONTROLLER 0.350310 0.025952
AIRLOOP M NW OA CONTROLLER 0.320861 0.025952
AIRLOOP M SE OA CONTROLLER 0.317028 0.025952
AIRLOOP M NE OA CONTROLLER 0.251089 0.025952
AIRLOOP M N1 OA CONTROLLER 0.169545 0.025952
AIRLOOP M N2 OA CONTROLLER 0.167992 0.025952
AIRLOOP M S1 OA CONTROLLER 0.226969 0.025952
AIRLOOP M S2 OA CONTROLLER 0.227929 0.025952
AIRLOOP F6 SW OA CONTROLLER 0.348302 0.025952
AIRLOOP F6 NW OA CONTROLLER 0.318735 0.025952
AIRLOOP F6 SE OA CONTROLLER 0.315863 0.025952
AIRLOOP F6 NE OA CONTROLLER 0.249205 0.025952
AIRLOOP F6 N1 OA CONTROLLER 0.167288 0.025952
AIRLOOP F6 N2 OA CONTROLLER 0.165746 0.025952
AIRLOOP F6 S1 OA CONTROLLER 0.225085 0.025952
AIRLOOP F6 S2 OA CONTROLLER 0.226041 0.025952
AIRLOOP F7 SW OA CONTROLLER 0.348372 0.025952
AIRLOOP F7 NW OA CONTROLLER 0.318782 0.025952
AIRLOOP F7 SE OA CONTROLLER 0.316679 0.025952
AIRLOOP F7 NE OA CONTROLLER 0.249425 0.025952
AIRLOOP F7 N1 OA CONTROLLER 0.167115 0.025952
AIRLOOP F7 N2 OA CONTROLLER 0.165581 0.025952
AIRLOOP F7 S1 OA CONTROLLER 0.225227 0.025952
AIRLOOP F7 S2 OA CONTROLLER 0.226182 0.025952
AIRLOOP F8 SW OA CONTROLLER 0.349698 0.025952
AIRLOOP F8 NW OA CONTROLLER 0.320098 0.025952
AIRLOOP F8 SE OA CONTROLLER 0.318580 0.025952
AIRLOOP F8 NE OA CONTROLLER 0.250791 0.025952
AIRLOOP F8 N1 OA CONTROLLER 0.168238 0.025952
AIRLOOP F8 N2 OA CONTROLLER 0.166714 0.025952
AIRLOOP F8 S1 OA CONTROLLER 0.226545 0.025952
AIRLOOP F8 S2 OA CONTROLLER 0.227502 0.025952
AIRLOOP F9 SW OA CONTROLLER 0.361483 0.025952
AIRLOOP F9 NW OA CONTROLLER 0.331466 0.025952
AIRLOOP F9 SE OA CONTROLLER 0.327754 0.025952
AIRLOOP F9 NE OA CONTROLLER 0.255699 0.025952
AIRLOOP F9 N1 OA CONTROLLER 0.178010 0.025952
AIRLOOP F9 N2 OA CONTROLLER 0.176478 0.025952
AIRLOOP F9 S1 OA CONTROLLER 0.234054 0.025952
AIRLOOP F9 S2 OA CONTROLLER 0.235107 0.025952
AIRLOOP T SW OA CONTROLLER 0.446752 0.025952
AIRLOOP T NW OA CONTROLLER 0.405202 0.025952
AIRLOOP T SE OA CONTROLLER 0.409650 0.025952
AIRLOOP T NE OA CONTROLLER 0.319637 0.025952
AIRLOOP T N1 OA CONTROLLER 0.240293 0.025952
AIRLOOP T N2 OA CONTROLLER 0.240115 0.025952
AIRLOOP T S1 OA CONTROLLER 0.326633 0.025952
AIRLOOP T S2 OA CONTROLLER 0.327472 0.025952


COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity [W] Rated Sensible Cooling Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP COOLING MODE AIRLOOP G SW 0.266307 3596.54 2587.54 0.000079
HEAT PUMP COOLING MODE AIRLOOP G NW 0.245974 3307.90 2383.07 0.000072
HEAT PUMP COOLING MODE AIRLOOP OFFICE 0.385195 5345.85 3810.25 0.000117
HEAT PUMP COOLING MODE AIRLOOP G NE 0.178831 2432.32 1758.73 0.000053
HEAT PUMP COOLING MODE AIRLOOP G N1 0.120314 1637.65 1184.05 0.000036
HEAT PUMP COOLING MODE AIRLOOP G N2 0.118360 1611.58 1165.49 0.000035
HEAT PUMP COOLING MODE AIRLOOP G S1 0.164237 2368.79 1669.08 0.000052
HEAT PUMP COOLING MODE AIRLOOP G S2 0.170995 2458.09 1733.38 0.000054
HEAT PUMP COOLING MODE AIRLOOP F2 SW 0.340752 4552.52 3285.58 0.000099
HEAT PUMP COOLING MODE AIRLOOP F2 NW 0.310262 4131.93 2985.45 0.000090
HEAT PUMP COOLING MODE AIRLOOP F2 SE 0.327454 4472.48 3205.42 0.000098
HEAT PUMP COOLING MODE AIRLOOP F2 NE 0.238457 3191.48 2317.14 0.000070
HEAT PUMP COOLING MODE AIRLOOP F2 N1 0.159432 2144.05 1552.22 0.000047
HEAT PUMP COOLING MODE AIRLOOP F2 N2 0.157864 2123.24 1537.37 0.000046
HEAT PUMP COOLING MODE AIRLOOP F2 S1 0.214707 3019.75 2145.15 0.000066
HEAT PUMP COOLING MODE AIRLOOP F2 S2 0.217214 3052.86 2168.94 0.000067
HEAT PUMP COOLING MODE AIRLOOP F3 SW 0.343432 4581.89 3312.29 0.000100
HEAT PUMP COOLING MODE AIRLOOP F3 NW 0.313937 4168.90 3021.74 0.000091
HEAT PUMP COOLING MODE AIRLOOP F3 SE 0.310405 4232.16 3040.79 0.000092
HEAT PUMP COOLING MODE AIRLOOP F3 NE 0.243881 3247.74 2365.18 0.000071
HEAT PUMP COOLING MODE AIRLOOP F3 N1 0.163563 2189.90 1589.45 0.000048
HEAT PUMP COOLING MODE AIRLOOP F3 N2 0.162001 2169.19 1574.65 0.000047
HEAT PUMP COOLING MODE AIRLOOP F3 S1 0.219865 3078.57 2192.08 0.000067
HEAT PUMP COOLING MODE AIRLOOP F3 S2 0.221042 3094.11 2203.24 0.000068
HEAT PUMP COOLING MODE AIRLOOP F4 SW 0.346018 4603.95 3334.15 0.000101
HEAT PUMP COOLING MODE AIRLOOP F4 NW 0.316536 4191.21 3043.74 0.000092
HEAT PUMP COOLING MODE AIRLOOP F4 SE 0.312031 4241.97 3053.68 0.000093
HEAT PUMP COOLING MODE AIRLOOP F4 NE 0.246639 3285.06 2394.05 0.000072
HEAT PUMP COOLING MODE AIRLOOP F4 N1 0.165741 2212.07 1608.64 0.000048
HEAT PUMP COOLING MODE AIRLOOP F4 N2 0.164183 2191.45 1593.89 0.000048
HEAT PUMP COOLING MODE AIRLOOP F4 S1 0.222651 3108.37 2216.99 0.000068
HEAT PUMP COOLING MODE AIRLOOP F4 S2 0.223639 3121.41 2226.36 0.000068
HEAT PUMP COOLING MODE AIRLOOP M SW 0.350310 4650.74 3372.60 0.000102
HEAT PUMP COOLING MODE AIRLOOP M NW 0.320861 4238.51 3082.52 0.000093
HEAT PUMP COOLING MODE AIRLOOP M SE 0.317028 4298.30 3098.90 0.000094
HEAT PUMP COOLING MODE AIRLOOP M NE 0.251089 3334.45 2434.15 0.000073
HEAT PUMP COOLING MODE AIRLOOP M N1 0.169545 2257.05 1643.51 0.000049
HEAT PUMP COOLING MODE AIRLOOP M N2 0.167992 2236.50 1628.81 0.000049
HEAT PUMP COOLING MODE AIRLOOP M S1 0.226969 3159.62 2256.70 0.000069
HEAT PUMP COOLING MODE AIRLOOP M S2 0.227929 3172.29 2265.80 0.000069
HEAT PUMP COOLING MODE AIRLOOP F6 SW 0.348302 4615.94 3351.85 0.000101
HEAT PUMP COOLING MODE AIRLOOP F6 NW 0.318735 4202.20 3060.66 0.000092
HEAT PUMP COOLING MODE AIRLOOP F6 SE 0.315863 4274.97 3086.17 0.000093
HEAT PUMP COOLING MODE AIRLOOP F6 NE 0.249205 3302.10 2414.75 0.000072
HEAT PUMP COOLING MODE AIRLOOP F6 N1 0.167288 2222.52 1621.16 0.000049
HEAT PUMP COOLING MODE AIRLOOP F6 N2 0.165746 2202.14 1606.57 0.000048
HEAT PUMP COOLING MODE AIRLOOP F6 S1 0.225085 3130.01 2237.82 0.000068
HEAT PUMP COOLING MODE AIRLOOP F6 S2 0.226041 3142.63 2246.88 0.000069
HEAT PUMP COOLING MODE AIRLOOP F7 SW 0.348372 4609.57 3350.95 0.000101
HEAT PUMP COOLING MODE AIRLOOP F7 NW 0.318782 4195.59 3059.57 0.000092
HEAT PUMP COOLING MODE AIRLOOP F7 SE 0.316679 4278.69 3092.38 0.000093
HEAT PUMP COOLING MODE AIRLOOP F7 NE 0.249425 3298.33 2415.42 0.000072
HEAT PUMP COOLING MODE AIRLOOP F7 N1 0.167115 2216.20 1618.67 0.000048
HEAT PUMP COOLING MODE AIRLOOP F7 N2 0.165581 2195.95 1604.16 0.000048
HEAT PUMP COOLING MODE AIRLOOP F7 S1 0.225227 3127.68 2238.26 0.000068
HEAT PUMP COOLING MODE AIRLOOP F7 S2 0.226182 3140.28 2247.31 0.000069
HEAT PUMP COOLING MODE AIRLOOP F8 SW 0.349698 4620.51 3362.08 0.000101
HEAT PUMP COOLING MODE AIRLOOP F8 NW 0.320098 4206.46 3070.62 0.000092
HEAT PUMP COOLING MODE AIRLOOP F8 SE 0.318580 4297.40 3109.01 0.000094
HEAT PUMP COOLING MODE AIRLOOP F8 NE 0.250791 3310.28 2427.05 0.000072
HEAT PUMP COOLING MODE AIRLOOP F8 N1 0.168238 2227.45 1628.52 0.000049
HEAT PUMP COOLING MODE AIRLOOP F8 N2 0.166714 2207.34 1614.11 0.000048
HEAT PUMP COOLING MODE AIRLOOP F8 S1 0.226545 3141.27 2249.94 0.000069
HEAT PUMP COOLING MODE AIRLOOP F8 S2 0.227502 3153.89 2259.01 0.000069
HEAT PUMP COOLING MODE AIRLOOP F9 SW 0.361483 4769.64 3472.09 0.000104
HEAT PUMP COOLING MODE AIRLOOP F9 NW 0.331466 4350.19 3176.71 0.000095
HEAT PUMP COOLING MODE AIRLOOP F9 SE 0.327754 4412.41 3194.52 0.000096
HEAT PUMP COOLING MODE AIRLOOP F9 NE 0.255699 3369.06 2472.21 0.000074
HEAT PUMP COOLING MODE AIRLOOP F9 N1 0.178010 2353.31 1720.28 0.000051
HEAT PUMP COOLING MODE AIRLOOP F9 N2 0.176478 2333.10 1705.79 0.000051
HEAT PUMP COOLING MODE AIRLOOP F9 S1 0.234054 3236.76 2320.35 0.000071
HEAT PUMP COOLING MODE AIRLOOP F9 S2 0.235107 3250.41 2330.28 0.000071
HEAT PUMP COOLING MODE AIRLOOP T SW 0.446752 5933.42 4300.71 0.000130
HEAT PUMP COOLING MODE AIRLOOP T NW 0.405202 5349.33 3888.52 0.000117
HEAT PUMP COOLING MODE AIRLOOP T SE 0.409650 5483.46 3966.99 0.000120
HEAT PUMP COOLING MODE AIRLOOP T NE 0.319637 4300.51 3116.70 0.000094
HEAT PUMP COOLING MODE AIRLOOP T N1 0.240293 3301.70 2372.87 0.000072
HEAT PUMP COOLING MODE AIRLOOP T N2 0.240115 3306.27 2374.11 0.000072
HEAT PUMP COOLING MODE AIRLOOP T S1 0.326633 4452.28 3195.64 0.000097
HEAT PUMP COOLING MODE AIRLOOP T S2 0.327472 4463.37 3203.58 0.000098


AirLoopHVAC:UnitaryHeatPump:WaterToAir

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Supplemental Heating Coil Nominal Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
AIRLOOP G SW DXAC HEAT PUMP 0.266307 0.266307 0.266307 0.266307 3596.54 3596.54 3760.47 1.00
AIRLOOP G NW DXAC HEAT PUMP 0.245974 0.245974 0.245974 0.245974 3307.90 3307.90 3775.08 1.00
AIRLOOP OFFICE DXAC HEAT PUMP 0.385195 0.385195 0.385195 0.385195 5345.85 5345.85 4652.81 1.00
AIRLOOP G NE DXAC HEAT PUMP 0.178831 0.178831 0.178831 0.178831 2432.32 2432.32 3770.34 1.00
AIRLOOP G N1 DXAC HEAT PUMP 0.120314 0.120314 0.120314 0.120314 1637.65 1637.65 2902.28 1.00
AIRLOOP G N2 DXAC HEAT PUMP 0.118360 0.118360 0.118360 0.118360 1611.58 1611.58 2902.17 1.00
AIRLOOP G S1 DXAC HEAT PUMP 0.164237 0.164237 0.164237 0.164237 2368.79 2368.79 2884.58 1.00
AIRLOOP G S2 DXAC HEAT PUMP 0.170995 0.170995 0.170995 0.170995 2458.09 2458.09 2890.75 1.00
AIRLOOP F2 SW DXAC HEAT PUMP 0.340752 0.340752 0.340752 0.340752 4552.52 4552.52 3613.42 1.00
AIRLOOP F2 NW DXAC HEAT PUMP 0.310262 0.310262 0.310262 0.310262 4131.93 4131.93 3620.19 1.00
AIRLOOP F2 SE DXAC HEAT PUMP 0.327454 0.327454 0.327454 0.327454 4472.48 4472.48 3627.05 1.00
AIRLOOP F2 NE DXAC HEAT PUMP 0.238457 0.238457 0.238457 0.238457 3191.48 3191.48 3615.49 1.00
AIRLOOP F2 N1 DXAC HEAT PUMP 0.159432 0.159432 0.159432 0.159432 2144.05 2144.05 2552.26 1.00
AIRLOOP F2 N2 DXAC HEAT PUMP 0.157864 0.157864 0.157864 0.157864 2123.24 2123.24 2552.15 1.00
AIRLOOP F2 S1 DXAC HEAT PUMP 0.214707 0.214707 0.214707 0.214707 3019.75 3019.75 2548.35 1.00
AIRLOOP F2 S2 DXAC HEAT PUMP 0.217214 0.217214 0.217214 0.217214 3052.86 3052.86 2549.39 1.00
AIRLOOP F3 SW DXAC HEAT PUMP 0.343432 0.343432 0.343432 0.343432 4581.89 4581.89 3612.74 1.00
AIRLOOP F3 NW DXAC HEAT PUMP 0.313937 0.313937 0.313937 0.313937 4168.90 4168.90 3619.74 1.00
AIRLOOP F3 SE DXAC HEAT PUMP 0.310405 0.310405 0.310405 0.310405 4232.16 4232.16 3610.92 1.00
AIRLOOP F3 NE DXAC HEAT PUMP 0.243881 0.243881 0.243881 0.243881 3247.74 3247.74 3615.99 1.00
AIRLOOP F3 N1 DXAC HEAT PUMP 0.163563 0.163563 0.163563 0.163563 2189.90 2189.90 2505.97 1.00
AIRLOOP F3 N2 DXAC HEAT PUMP 0.162001 0.162001 0.162001 0.162001 2169.19 2169.19 2505.88 1.00
AIRLOOP F3 S1 DXAC HEAT PUMP 0.219865 0.219865 0.219865 0.219865 3078.57 3078.57 2499.87 1.00
AIRLOOP F3 S2 DXAC HEAT PUMP 0.221042 0.221042 0.221042 0.221042 3094.11 3094.11 2499.96 1.00
AIRLOOP F4 SW DXAC HEAT PUMP 0.346018 0.346018 0.346018 0.346018 4603.95 4603.95 3678.92 1.00
AIRLOOP F4 NW DXAC HEAT PUMP 0.316536 0.316536 0.316536 0.316536 4191.21 4191.21 3685.23 1.00
AIRLOOP F4 SE DXAC HEAT PUMP 0.312031 0.312031 0.312031 0.312031 4241.97 4241.97 3676.25 1.00
AIRLOOP F4 NE DXAC HEAT PUMP 0.246639 0.246639 0.246639 0.246639 3285.06 3285.06 3682.36 1.00
AIRLOOP F4 N1 DXAC HEAT PUMP 0.165741 0.165741 0.165741 0.165741 2212.07 2212.07 2533.67 1.00
AIRLOOP F4 N2 DXAC HEAT PUMP 0.164183 0.164183 0.164183 0.164183 2191.45 2191.45 2533.60 1.00
AIRLOOP F4 S1 DXAC HEAT PUMP 0.222651 0.222651 0.222651 0.222651 3108.37 3108.37 2527.99 1.00
AIRLOOP F4 S2 DXAC HEAT PUMP 0.223639 0.223639 0.223639 0.223639 3121.41 3121.41 2527.95 1.00
AIRLOOP M SW DXAC HEAT PUMP 0.350310 0.350310 0.350310 0.350310 4650.74 4650.74 3724.22 1.00
AIRLOOP M NW DXAC HEAT PUMP 0.320861 0.320861 0.320861 0.320861 4238.51 4238.51 3728.46 1.00
AIRLOOP M SE DXAC HEAT PUMP 0.317028 0.317028 0.317028 0.317028 4298.30 4298.30 3722.17 1.00
AIRLOOP M NE DXAC HEAT PUMP 0.251089 0.251089 0.251089 0.251089 3334.45 3334.45 3726.39 1.00
AIRLOOP M N1 DXAC HEAT PUMP 0.169545 0.169545 0.169545 0.169545 2257.05 2257.05 2546.94 1.00
AIRLOOP M N2 DXAC HEAT PUMP 0.167992 0.167992 0.167992 0.167992 2236.50 2236.50 2546.89 1.00
AIRLOOP M S1 DXAC HEAT PUMP 0.226969 0.226969 0.226969 0.226969 3159.62 3159.62 2543.31 1.00
AIRLOOP M S2 DXAC HEAT PUMP 0.227929 0.227929 0.227929 0.227929 3172.29 3172.29 2543.26 1.00
AIRLOOP F6 SW DXAC HEAT PUMP 0.348302 0.348302 0.348302 0.348302 4615.94 4615.94 3825.60 1.00
AIRLOOP F6 NW DXAC HEAT PUMP 0.318735 0.318735 0.318735 0.318735 4202.20 4202.20 3829.61 1.00
AIRLOOP F6 SE DXAC HEAT PUMP 0.315863 0.315863 0.315863 0.315863 4274.97 4274.97 3824.25 1.00
AIRLOOP F6 NE DXAC HEAT PUMP 0.249205 0.249205 0.249205 0.249205 3302.10 3302.10 3828.26 1.00
AIRLOOP F6 N1 DXAC HEAT PUMP 0.167288 0.167288 0.167288 0.167288 2222.52 2222.52 2621.07 1.00
AIRLOOP F6 N2 DXAC HEAT PUMP 0.165746 0.165746 0.165746 0.165746 2202.14 2202.14 2621.04 1.00
AIRLOOP F6 S1 DXAC HEAT PUMP 0.225085 0.225085 0.225085 0.225085 3130.01 3130.01 2617.65 1.00
AIRLOOP F6 S2 DXAC HEAT PUMP 0.226041 0.226041 0.226041 0.226041 3142.63 3142.63 2617.62 1.00
AIRLOOP F7 SW DXAC HEAT PUMP 0.348372 0.348372 0.348372 0.348372 4609.57 4609.57 3898.88 1.00
AIRLOOP F7 NW DXAC HEAT PUMP 0.318782 0.318782 0.318782 0.318782 4195.59 4195.59 3901.65 1.00
AIRLOOP F7 SE DXAC HEAT PUMP 0.316679 0.316679 0.316679 0.316679 4278.69 4278.69 3898.18 1.00
AIRLOOP F7 NE DXAC HEAT PUMP 0.249425 0.249425 0.249425 0.249425 3298.33 3298.33 3900.95 1.00
AIRLOOP F7 N1 DXAC HEAT PUMP 0.167115 0.167115 0.167115 0.167115 2216.20 2216.20 2670.23 1.00
AIRLOOP F7 N2 DXAC HEAT PUMP 0.165581 0.165581 0.165581 0.165581 2195.95 2195.95 2670.21 1.00
AIRLOOP F7 S1 DXAC HEAT PUMP 0.225227 0.225227 0.225227 0.225227 3127.68 3127.68 2668.08 1.00
AIRLOOP F7 S2 DXAC HEAT PUMP 0.226182 0.226182 0.226182 0.226182 3140.28 3140.28 2668.06 1.00
AIRLOOP F8 SW DXAC HEAT PUMP 0.349698 0.349698 0.349698 0.349698 4620.51 4620.51 3977.43 1.00
AIRLOOP F8 NW DXAC HEAT PUMP 0.320098 0.320098 0.320098 0.320098 4206.46 4206.46 3978.75 1.00
AIRLOOP F8 SE DXAC HEAT PUMP 0.318580 0.318580 0.318580 0.318580 4297.40 4297.40 3977.33 1.00
AIRLOOP F8 NE DXAC HEAT PUMP 0.250791 0.250791 0.250791 0.250791 3310.28 3310.28 3978.65 1.00
AIRLOOP F8 N1 DXAC HEAT PUMP 0.168238 0.168238 0.168238 0.168238 2227.45 2227.45 2727.07 1.00
AIRLOOP F8 N2 DXAC HEAT PUMP 0.166714 0.166714 0.166714 0.166714 2207.34 2207.34 2727.06 1.00
AIRLOOP F8 S1 DXAC HEAT PUMP 0.226545 0.226545 0.226545 0.226545 3141.27 3141.27 2726.37 1.00
AIRLOOP F8 S2 DXAC HEAT PUMP 0.227502 0.227502 0.227502 0.227502 3153.89 3153.89 2726.37 1.00
AIRLOOP F9 SW DXAC HEAT PUMP 0.361483 0.361483 0.361483 0.361483 4769.64 4769.64 4203.83 1.00
AIRLOOP F9 NW DXAC HEAT PUMP 0.331466 0.331466 0.331466 0.331466 4350.19 4350.19 4200.93 1.00
AIRLOOP F9 SE DXAC HEAT PUMP 0.327754 0.327754 0.327754 0.327754 4412.41 4412.41 4204.28 1.00
AIRLOOP F9 NE DXAC HEAT PUMP 0.255699 0.255699 0.255699 0.255699 3369.06 3369.06 4201.39 1.00
AIRLOOP F9 N1 DXAC HEAT PUMP 0.178010 0.178010 0.178010 0.178010 2353.31 2353.31 2921.24 1.00
AIRLOOP F9 N2 DXAC HEAT PUMP 0.176478 0.176478 0.176478 0.176478 2333.10 2333.10 2921.25 1.00
AIRLOOP F9 S1 DXAC HEAT PUMP 0.234054 0.234054 0.234054 0.234054 3236.76 3236.76 2924.33 1.00
AIRLOOP F9 S2 DXAC HEAT PUMP 0.235107 0.235107 0.235107 0.235107 3250.41 3250.41 2924.34 1.00
AIRLOOP T SW DXAC HEAT PUMP 0.446752 0.446752 0.446752 0.446752 5933.42 5933.42 4999.34 1.00
AIRLOOP T NW DXAC HEAT PUMP 0.405202 0.405202 0.405202 0.405202 5349.33 5349.33 5003.61 1.00
AIRLOOP T SE DXAC HEAT PUMP 0.409650 0.409650 0.409650 0.409650 5483.46 5483.46 5000.21 1.00
AIRLOOP T NE DXAC HEAT PUMP 0.319637 0.319637 0.319637 0.319637 4300.51 4300.51 5004.47 1.00
AIRLOOP T N1 DXAC HEAT PUMP 0.240293 0.240293 0.240293 0.240293 3301.70 3301.70 3771.06 1.00
AIRLOOP T N2 DXAC HEAT PUMP 0.240115 0.240115 0.240115 0.240115 3306.27 3306.27 3771.08 1.00
AIRLOOP T S1 DXAC HEAT PUMP 0.326633 0.326633 0.326633 0.326633 4452.28 4452.28 3764.02 1.00
AIRLOOP T S2 DXAC HEAT PUMP 0.327472 0.327472 0.327472 0.327472 4463.37 4463.37 3764.04 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
AIRLOOP G SW SUPPLY FAN 0.266307
AIRLOOP G NW SUPPLY FAN 0.245974
AIRLOOP OFFICE SUPPLY FAN 0.385195
AIRLOOP G NE SUPPLY FAN 0.178831
AIRLOOP G N1 SUPPLY FAN 0.120314
AIRLOOP G N2 SUPPLY FAN 0.118360
AIRLOOP G S1 SUPPLY FAN 0.164237
AIRLOOP G S2 SUPPLY FAN 0.170995
AIRLOOP F2 SW SUPPLY FAN 0.340752
AIRLOOP F2 NW SUPPLY FAN 0.310262
AIRLOOP F2 SE SUPPLY FAN 0.327454
AIRLOOP F2 NE SUPPLY FAN 0.238457
AIRLOOP F2 N1 SUPPLY FAN 0.159432
AIRLOOP F2 N2 SUPPLY FAN 0.157864
AIRLOOP F2 S1 SUPPLY FAN 0.214707
AIRLOOP F2 S2 SUPPLY FAN 0.217214
AIRLOOP F3 SW SUPPLY FAN 0.343432
AIRLOOP F3 NW SUPPLY FAN 0.313937
AIRLOOP F3 SE SUPPLY FAN 0.310405
AIRLOOP F3 NE SUPPLY FAN 0.243881
AIRLOOP F3 N1 SUPPLY FAN 0.163563
AIRLOOP F3 N2 SUPPLY FAN 0.162001
AIRLOOP F3 S1 SUPPLY FAN 0.219865
AIRLOOP F3 S2 SUPPLY FAN 0.221042
AIRLOOP F4 SW SUPPLY FAN 0.346018
AIRLOOP F4 NW SUPPLY FAN 0.316536
AIRLOOP F4 SE SUPPLY FAN 0.312031
AIRLOOP F4 NE SUPPLY FAN 0.246639
AIRLOOP F4 N1 SUPPLY FAN 0.165741
AIRLOOP F4 N2 SUPPLY FAN 0.164183
AIRLOOP F4 S1 SUPPLY FAN 0.222651
AIRLOOP F4 S2 SUPPLY FAN 0.223639
AIRLOOP M SW SUPPLY FAN 0.350310
AIRLOOP M NW SUPPLY FAN 0.320861
AIRLOOP M SE SUPPLY FAN 0.317028
AIRLOOP M NE SUPPLY FAN 0.251089
AIRLOOP M N1 SUPPLY FAN 0.169545
AIRLOOP M N2 SUPPLY FAN 0.167992
AIRLOOP M S1 SUPPLY FAN 0.226969
AIRLOOP M S2 SUPPLY FAN 0.227929
AIRLOOP F6 SW SUPPLY FAN 0.348302
AIRLOOP F6 NW SUPPLY FAN 0.318735
AIRLOOP F6 SE SUPPLY FAN 0.315863
AIRLOOP F6 NE SUPPLY FAN 0.249205
AIRLOOP F6 N1 SUPPLY FAN 0.167288
AIRLOOP F6 N2 SUPPLY FAN 0.165746
AIRLOOP F6 S1 SUPPLY FAN 0.225085
AIRLOOP F6 S2 SUPPLY FAN 0.226041
AIRLOOP F7 SW SUPPLY FAN 0.348372
AIRLOOP F7 NW SUPPLY FAN 0.318782
AIRLOOP F7 SE SUPPLY FAN 0.316679
AIRLOOP F7 NE SUPPLY FAN 0.249425
AIRLOOP F7 N1 SUPPLY FAN 0.167115
AIRLOOP F7 N2 SUPPLY FAN 0.165581
AIRLOOP F7 S1 SUPPLY FAN 0.225227
AIRLOOP F7 S2 SUPPLY FAN 0.226182
AIRLOOP F8 SW SUPPLY FAN 0.349698
AIRLOOP F8 NW SUPPLY FAN 0.320098
AIRLOOP F8 SE SUPPLY FAN 0.318580
AIRLOOP F8 NE SUPPLY FAN 0.250791
AIRLOOP F8 N1 SUPPLY FAN 0.168238
AIRLOOP F8 N2 SUPPLY FAN 0.166714
AIRLOOP F8 S1 SUPPLY FAN 0.226545
AIRLOOP F8 S2 SUPPLY FAN 0.227502
AIRLOOP F9 SW SUPPLY FAN 0.361483
AIRLOOP F9 NW SUPPLY FAN 0.331466
AIRLOOP F9 SE SUPPLY FAN 0.327754
AIRLOOP F9 NE SUPPLY FAN 0.255699
AIRLOOP F9 N1 SUPPLY FAN 0.178010
AIRLOOP F9 N2 SUPPLY FAN 0.176478
AIRLOOP F9 S1 SUPPLY FAN 0.234054
AIRLOOP F9 S2 SUPPLY FAN 0.235107
AIRLOOP T SW SUPPLY FAN 0.446752
AIRLOOP T NW SUPPLY FAN 0.405202
AIRLOOP T SE SUPPLY FAN 0.409650
AIRLOOP T NE SUPPLY FAN 0.319637
AIRLOOP T N1 SUPPLY FAN 0.240293
AIRLOOP T N2 SUPPLY FAN 0.240115
AIRLOOP T S1 SUPPLY FAN 0.326633
AIRLOOP T S2 SUPPLY FAN 0.327472


COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT

Rated Air Flow Rate [m3/s] Rated Heating Capacity [W] Rated Water Flow Rate [m3/s]
HEAT PUMP HEATING MODE AIRLOOP G SW 0.266307 3596.54 0.000079
HEAT PUMP HEATING MODE AIRLOOP G NW 0.245974 3307.90 0.000072
HEAT PUMP HEATING MODE AIRLOOP OFFICE 0.385195 5345.85 0.000117
HEAT PUMP HEATING MODE AIRLOOP G NE 0.178831 2432.32 0.000053
HEAT PUMP HEATING MODE AIRLOOP G N1 0.120314 1637.65 0.000036
HEAT PUMP HEATING MODE AIRLOOP G N2 0.118360 1611.58 0.000035
HEAT PUMP HEATING MODE AIRLOOP G S1 0.164237 2368.79 0.000052
HEAT PUMP HEATING MODE AIRLOOP G S2 0.170995 2458.09 0.000054
HEAT PUMP HEATING MODE AIRLOOP F2 SW 0.340752 4552.52 0.000099
HEAT PUMP HEATING MODE AIRLOOP F2 NW 0.310262 4131.93 0.000090
HEAT PUMP HEATING MODE AIRLOOP F2 SE 0.327454 4472.48 0.000098
HEAT PUMP HEATING MODE AIRLOOP F2 NE 0.238457 3191.48 0.000070
HEAT PUMP HEATING MODE AIRLOOP F2 N1 0.159432 2144.05 0.000047
HEAT PUMP HEATING MODE AIRLOOP F2 N2 0.157864 2123.24 0.000046
HEAT PUMP HEATING MODE AIRLOOP F2 S1 0.214707 3019.75 0.000066
HEAT PUMP HEATING MODE AIRLOOP F2 S2 0.217214 3052.86 0.000067
HEAT PUMP HEATING MODE AIRLOOP F3 SW 0.343432 4581.89 0.000100
HEAT PUMP HEATING MODE AIRLOOP F3 NW 0.313937 4168.90 0.000091
HEAT PUMP HEATING MODE AIRLOOP F3 SE 0.310405 4232.16 0.000092
HEAT PUMP HEATING MODE AIRLOOP F3 NE 0.243881 3247.74 0.000071
HEAT PUMP HEATING MODE AIRLOOP F3 N1 0.163563 2189.90 0.000048
HEAT PUMP HEATING MODE AIRLOOP F3 N2 0.162001 2169.19 0.000047
HEAT PUMP HEATING MODE AIRLOOP F3 S1 0.219865 3078.57 0.000067
HEAT PUMP HEATING MODE AIRLOOP F3 S2 0.221042 3094.11 0.000068
HEAT PUMP HEATING MODE AIRLOOP F4 SW 0.346018 4603.95 0.000101
HEAT PUMP HEATING MODE AIRLOOP F4 NW 0.316536 4191.21 0.000092
HEAT PUMP HEATING MODE AIRLOOP F4 SE 0.312031 4241.97 0.000093
HEAT PUMP HEATING MODE AIRLOOP F4 NE 0.246639 3285.06 0.000072
HEAT PUMP HEATING MODE AIRLOOP F4 N1 0.165741 2212.07 0.000048
HEAT PUMP HEATING MODE AIRLOOP F4 N2 0.164183 2191.45 0.000048
HEAT PUMP HEATING MODE AIRLOOP F4 S1 0.222651 3108.37 0.000068
HEAT PUMP HEATING MODE AIRLOOP F4 S2 0.223639 3121.41 0.000068
HEAT PUMP HEATING MODE AIRLOOP M SW 0.350310 4650.74 0.000102
HEAT PUMP HEATING MODE AIRLOOP M NW 0.320861 4238.51 0.000093
HEAT PUMP HEATING MODE AIRLOOP M SE 0.317028 4298.30 0.000094
HEAT PUMP HEATING MODE AIRLOOP M NE 0.251089 3334.45 0.000073
HEAT PUMP HEATING MODE AIRLOOP M N1 0.169545 2257.05 0.000049
HEAT PUMP HEATING MODE AIRLOOP M N2 0.167992 2236.50 0.000049
HEAT PUMP HEATING MODE AIRLOOP M S1 0.226969 3159.62 0.000069
HEAT PUMP HEATING MODE AIRLOOP M S2 0.227929 3172.29 0.000069
HEAT PUMP HEATING MODE AIRLOOP F6 SW 0.348302 4615.94 0.000101
HEAT PUMP HEATING MODE AIRLOOP F6 NW 0.318735 4202.20 0.000092
HEAT PUMP HEATING MODE AIRLOOP F6 SE 0.315863 4274.97 0.000093
HEAT PUMP HEATING MODE AIRLOOP F6 NE 0.249205 3302.10 0.000072
HEAT PUMP HEATING MODE AIRLOOP F6 N1 0.167288 2222.52 0.000049
HEAT PUMP HEATING MODE AIRLOOP F6 N2 0.165746 2202.14 0.000048
HEAT PUMP HEATING MODE AIRLOOP F6 S1 0.225085 3130.01 0.000068
HEAT PUMP HEATING MODE AIRLOOP F6 S2 0.226041 3142.63 0.000069
HEAT PUMP HEATING MODE AIRLOOP F7 SW 0.348372 4609.57 0.000101
HEAT PUMP HEATING MODE AIRLOOP F7 NW 0.318782 4195.59 0.000092
HEAT PUMP HEATING MODE AIRLOOP F7 SE 0.316679 4278.69 0.000093
HEAT PUMP HEATING MODE AIRLOOP F7 NE 0.249425 3298.33 0.000072
HEAT PUMP HEATING MODE AIRLOOP F7 N1 0.167115 2216.20 0.000048
HEAT PUMP HEATING MODE AIRLOOP F7 N2 0.165581 2195.95 0.000048
HEAT PUMP HEATING MODE AIRLOOP F7 S1 0.225227 3127.68 0.000068
HEAT PUMP HEATING MODE AIRLOOP F7 S2 0.226182 3140.28 0.000069
HEAT PUMP HEATING MODE AIRLOOP F8 SW 0.349698 4620.51 0.000101
HEAT PUMP HEATING MODE AIRLOOP F8 NW 0.320098 4206.46 0.000092
HEAT PUMP HEATING MODE AIRLOOP F8 SE 0.318580 4297.40 0.000094
HEAT PUMP HEATING MODE AIRLOOP F8 NE 0.250791 3310.28 0.000072
HEAT PUMP HEATING MODE AIRLOOP F8 N1 0.168238 2227.45 0.000049
HEAT PUMP HEATING MODE AIRLOOP F8 N2 0.166714 2207.34 0.000048
HEAT PUMP HEATING MODE AIRLOOP F8 S1 0.226545 3141.27 0.000069
HEAT PUMP HEATING MODE AIRLOOP F8 S2 0.227502 3153.89 0.000069
HEAT PUMP HEATING MODE AIRLOOP F9 SW 0.361483 4769.64 0.000104
HEAT PUMP HEATING MODE AIRLOOP F9 NW 0.331466 4350.19 0.000095
HEAT PUMP HEATING MODE AIRLOOP F9 SE 0.327754 4412.41 0.000096
HEAT PUMP HEATING MODE AIRLOOP F9 NE 0.255699 3369.06 0.000074
HEAT PUMP HEATING MODE AIRLOOP F9 N1 0.178010 2353.31 0.000051
HEAT PUMP HEATING MODE AIRLOOP F9 N2 0.176478 2333.10 0.000051
HEAT PUMP HEATING MODE AIRLOOP F9 S1 0.234054 3236.76 0.000071
HEAT PUMP HEATING MODE AIRLOOP F9 S2 0.235107 3250.41 0.000071
HEAT PUMP HEATING MODE AIRLOOP T SW 0.446752 5933.42 0.000130
HEAT PUMP HEATING MODE AIRLOOP T NW 0.405202 5349.33 0.000117
HEAT PUMP HEATING MODE AIRLOOP T SE 0.409650 5483.46 0.000120
HEAT PUMP HEATING MODE AIRLOOP T NE 0.319637 4300.51 0.000094
HEAT PUMP HEATING MODE AIRLOOP T N1 0.240293 3301.70 0.000072
HEAT PUMP HEATING MODE AIRLOOP T N2 0.240115 3306.27 0.000072
HEAT PUMP HEATING MODE AIRLOOP T S1 0.326633 4452.28 0.000097
HEAT PUMP HEATING MODE AIRLOOP T S2 0.327472 4463.37 0.000098


Coil:Heating:Electric

Nominal Capacity [W]
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G SW 3760.47
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NW 3775.08
HEAT PUMP DX SUPP HEATING COIL AIRLOOP OFFICE 4652.81
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G NE 3770.34
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N1 2902.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G N2 2902.17
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S1 2884.58
HEAT PUMP DX SUPP HEATING COIL AIRLOOP G S2 2890.75
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SW 3613.42
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NW 3620.19
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 SE 3627.05
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 NE 3615.49
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N1 2552.26
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 N2 2552.15
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S1 2548.35
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F2 S2 2549.39
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SW 3612.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NW 3619.74
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 SE 3610.92
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 NE 3615.99
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N1 2505.97
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 N2 2505.88
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S1 2499.87
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F3 S2 2499.96
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SW 3678.92
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NW 3685.23
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 SE 3676.25
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 NE 3682.36
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N1 2533.67
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 N2 2533.60
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S1 2527.99
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F4 S2 2527.95
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SW 3724.22
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NW 3728.46
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M SE 3722.17
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M NE 3726.39
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N1 2546.94
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M N2 2546.89
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S1 2543.31
HEAT PUMP DX SUPP HEATING COIL AIRLOOP M S2 2543.26
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SW 3825.60
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NW 3829.61
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 SE 3824.25
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 NE 3828.26
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N1 2621.07
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 N2 2621.04
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S1 2617.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F6 S2 2617.62
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SW 3898.88
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NW 3901.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 SE 3898.18
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 NE 3900.95
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N1 2670.23
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 N2 2670.21
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S1 2668.08
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F7 S2 2668.06
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SW 3977.43
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NW 3978.75
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 SE 3977.33
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 NE 3978.65
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N1 2727.07
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 N2 2727.06
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S1 2726.37
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F8 S2 2726.37
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SW 4203.83
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NW 4200.93
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 SE 4204.28
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 NE 4201.39
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N1 2921.24
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 N2 2921.25
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S1 2924.33
HEAT PUMP DX SUPP HEATING COIL AIRLOOP F9 S2 2924.34
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SW 4999.34
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NW 5003.61
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T SE 5000.21
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T NE 5004.47
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N1 3771.06
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T N2 3771.08
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S1 3764.02
HEAT PUMP DX SUPP HEATING COIL AIRLOOP T S2 3764.04


PlantLoop

Maximum Loop Flow Rate [m3/s] Plant Loop Volume [m3]
SHWSYS1 0.000289 0.325214
SINGLE WATER PLANT LOOP 0.006040 6.79


Boiler:HotWater

Design Water Flow Rate [m3/s]
CENTRAL BOILER 0.006040


WaterHeater:Mixed

Use Side Design Flow Rate [m3/s]
SHWSYS1 WATER HEATER 0.000289


EvaporativeFluidCooler:SingleSpeed

Design Water Flow Rate [m3/s] Fan Power at Design Air Flow Rate [W] Design Air Flow Rate [m3/s] U-Factor Times Area Value at Design Air Flow Rate [W/C]
CENTRAL TOWER 0.006040 2915.75 8.34 8315.99


Pump:ConstantSpeed

Rated Flow Rate [m3/s] Rated Power Consumption [W]
SHWSYS1 PUMP 0.000289 36.93
PLANT CIRC PUMP 0.006040 1928.84



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW3 |
G WWALL SWA GWINDOW2 |
G NWALL NWA GWINDOW4 |
G WWALL NWA GWINDOW6 |
G SWALL SEA GWINDOW1 |
G EWALL SEA GWINDOW8 |
G NWALL NEA GWINDOW5 |
G EWALL NEA GWINDOW7 |
G NWALL N1A GWINDOW9 |
G NWALL N2A GWINDOW10 |
G SWALL S1A GWINDOW11 |
G SWALL S2A GWINDOW12 |
G WWALL C GWINDOW13 |
G EWALL C ENTRANCE DOOR |
F2 WWALL SWA F2WINDOW2 |
F2 SWALL SWA F2WINDOW3 |
F2 NWALL NWA F2WINDOW4 |
F2 WWALL NWA F2WINDOW6 |
F2 EWALL SEA F2WINDOW8 |
F2 SWALL SEA F2WINDOW1 |
F2 NWALL NEA F2WINDOW5 |
F2 EWALL NEA F2WINDOW7 |
F2 NWALL N1A F2WINDOW9 |
F2 NWALL N2A F2WINDOW10 |
F2 SWALL S1A F2WINDOW11 |
F2 SWALL S2A F2WINDOW12 |
F2 WWALL C F2WINDOW13 |
F2 EWALL C F2WINDOW14 |
F3 WWALL SWA F3WINDOW2 |
F3 SWALL SWA F3WINDOW3 |
F3 NWALL NWA F3WINDOW4 |
F3 WWALL NWA F3WINDOW6 |
F3 EWALL SEA F3WINDOW8 |
F3 SWALL SEA F3WINDOW1 |
F3 NWALL NEA F3WINDOW5 |
F3 EWALL NEA F3WINDOW7 |
F3 NWALL N1A F3WINDOW9 |
F3 NWALL N2A F3WINDOW10 |
F3 SWALL S1A F3WINDOW11 |
F3 SWALL S2A F3WINDOW12 |
F3 WWALL C F3WINDOW13 |
F3 EWALL C F3WINDOW14 |
F4 WWALL SWA F4WINDOW2 |
F4 SWALL SWA F4WINDOW3 |
F4 NWALL NWA F4WINDOW4 |
F4 WWALL NWA F4WINDOW6 |
F4 EWALL SEA F4WINDOW8 |
F4 SWALL SEA F4WINDOW1 |
F4 NWALL NEA F4WINDOW5 |
F4 EWALL NEA F4WINDOW7 |
F4 NWALL N1A F4WINDOW9 |
F4 NWALL N2A F4WINDOW10 |
F4 SWALL S1A F4WINDOW11 |
F4 SWALL S2A F4WINDOW12 |
F4 WWALL C F4WINDOW13 |
F4 EWALL C F4WINDOW14 |
M WWALL SWA MWINDOW2 |
M SWALL SWA MWINDOW3 |
M NWALL NWA MWINDOW4 |
M WWALL NWA MWINDOW6 |
M EWALL SEA MWINDOW8 |
M SWALL SEA MWINDOW1 |
M NWALL NEA MWINDOW5 |
M EWALL NEA MWINDOW7 |
M NWALL N1A MWINDOW9 |
M NWALL N2A MWINDOW10 |
M SWALL S1A MWINDOW11 |
M SWALL S2A MWINDOW12 |
M WWALL C MWINDOW13 |
M EWALL C MWINDOW14 |
F6 WWALL SWA F6WINDOW2 |
F6 SWALL SWA F6WINDOW3 |
F6 NWALL NWA F6WINDOW4 |
F6 WWALL NWA F6WINDOW6 |
F6 EWALL SEA F6WINDOW8 |
F6 SWALL SEA F6WINDOW1 |
F6 NWALL NEA F6WINDOW5 |
F6 EWALL NEA F6WINDOW7 |
F6 NWALL N1A F6WINDOW9 |
F6 NWALL N2A F6WINDOW10 |
F6 SWALL S1A F6WINDOW11 |
F6 SWALL S2A F6WINDOW12 |
F6 WWALL C F6WINDOW13 |
F6 EWALL C F6WINDOW14 |
F7 WWALL SWA F7WINDOW2 |
F7 SWALL SWA F7WINDOW3 |
F7 NWALL NWA F7WINDOW4 |
F7 WWALL NWA F7WINDOW6 |
F7 EWALL SEA F7WINDOW8 |
F7 SWALL SEA F7WINDOW1 |
F7 NWALL NEA F7WINDOW5 |
F7 EWALL NEA F7WINDOW7 |
F7 NWALL N1A F7WINDOW9 |
F7 NWALL N2A F7WINDOW10 |
F7 SWALL S1A F7WINDOW11 |
F7 SWALL S2A F7WINDOW12 |
F7 WWALL C F7WINDOW13 |
F7 EWALL C F7WINDOW14 |
F8 WWALL SWA F8WINDOW2 |
F8 SWALL SWA F8WINDOW3 |
F8 NWALL NWA F8WINDOW4 |
F8 WWALL NWA F8WINDOW6 |
F8 EWALL SEA F8WINDOW8 |
F8 SWALL SEA F8WINDOW1 |
F8 NWALL NEA F8WINDOW5 |
F8 EWALL NEA F8WINDOW7 |
F8 NWALL N1A F8WINDOW9 |
F8 NWALL N2A F8WINDOW10 |
F8 SWALL S1A F8WINDOW11 |
F8 SWALL S2A F8WINDOW12 |
F8 WWALL C F8WINDOW13 |
F8 EWALL C F8WINDOW14 |
F9 WWALL SWA F9WINDOW2 |
F9 SWALL SWA F9WINDOW3 |
F9 NWALL NWA F9WINDOW4 |
F9 WWALL NWA F9WINDOW6 |
F9 EWALL SEA F9WINDOW8 |
F9 SWALL SEA F9WINDOW1 |
F9 NWALL NEA F9WINDOW5 |
F9 EWALL NEA F9WINDOW7 |
F9 NWALL N1A F9WINDOW9 |
F9 NWALL N2A F9WINDOW10 |
F9 SWALL S1A F9WINDOW11 |
F9 SWALL S2A F9WINDOW12 |
F9 WWALL C F9WINDOW13 |
F9 EWALL C F9WINDOW14 |
T WWALL SWA TWINDOW2 |
T SWALL SWA TWINDOW3 |
T NWALL NWA TWINDOW4 |
T WWALL NWA TWINDOW6 |
T EWALL SEA TWINDOW8 |
T SWALL SEA TWINDOW1 |
T NWALL NEA TWINDOW5 |
T EWALL NEA TWINDOW7 |
T NWALL N1A TWINDOW9 |
T NWALL N2A TWINDOW10 |
T SWALL S1A TWINDOW11 |
T SWALL S2A TWINDOW12 |
T WWALL C TWINDOW13 |
T EWALL C TWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2015-09-09 19:00:31

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.77 -1.7
February 22.03 2.70
March 22.28 6.07
April 23.06 11.58
May 23.40 14.61
June 24.16 19.78
July 24.35 24.54
August 24.30 21.22
September 24.17 17.37
October 23.25 11.70
November 22.14 4.05
December 21.88 1.86
     
Annual Sum or Average 23.07 11.20
Minimum of Months 21.77 -1.7
Maximum of Months 24.35 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.72 2.70
March 21.84 6.07
April 22.60 11.58
May 23.15 14.61
June 24.14 19.78
July 24.35 24.54
August 24.23 21.22
September 23.96 17.37
October 22.47 11.70
November 21.76 4.05
December 21.70 1.86
     
Annual Sum or Average 22.81 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.35 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.01 -1.7
February 22.25 2.70
March 22.63 6.07
April 23.43 11.58
May 23.80 14.61
June 24.29 19.78
July 24.40 24.54
August 24.35 21.22
September 24.29 17.37
October 23.54 11.70
November 22.47 4.05
December 22.12 1.86
     
Annual Sum or Average 23.30 11.20
Minimum of Months 22.01 -1.7
Maximum of Months 24.40 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.70 2.70
March 21.78 6.07
April 22.54 11.58
May 23.06 14.61
June 24.13 19.78
July 24.36 24.54
August 24.20 21.22
September 23.88 17.37
October 22.39 11.70
November 21.74 4.05
December 21.70 1.86
     
Annual Sum or Average 22.77 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.36 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.70 2.70
March 21.74 6.07
April 22.31 11.58
May 22.78 14.61
June 24.04 19.78
July 24.34 24.54
August 24.14 21.22
September 23.80 17.37
October 22.27 11.70
November 21.74 4.05
December 21.70 1.86
     
Annual Sum or Average 22.69 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.34 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.70 2.70
March 21.74 6.07
April 22.31 11.58
May 22.77 14.61
June 24.04 19.78
July 24.34 24.54
August 24.14 21.22
September 23.80 17.37
October 22.27 11.70
November 21.74 4.05
December 21.70 1.86
     
Annual Sum or Average 22.69 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.34 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.79 -1.7
February 22.05 2.70
March 22.28 6.07
April 22.99 11.58
May 23.22 14.61
June 24.13 19.78
July 24.32 24.54
August 24.27 21.22
September 24.18 17.37
October 23.35 11.70
November 22.20 4.05
December 21.92 1.86
     
Annual Sum or Average 23.06 11.20
Minimum of Months 21.79 -1.7
Maximum of Months 24.32 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.80 -1.7
February 22.07 2.70
March 22.32 6.07
April 23.06 11.58
May 23.29 14.61
June 24.15 19.78
July 24.32 24.54
August 24.28 21.22
September 24.20 17.37
October 23.40 11.70
November 22.23 4.05
December 21.94 1.86
     
Annual Sum or Average 23.09 11.20
Minimum of Months 21.80 -1.7
Maximum of Months 24.32 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 15.22 -1.7
February 16.84 2.70
March 18.07 6.07
April 20.38 11.58
May 21.52 14.61
June 24.27 19.78
July 26.04 24.54
August 25.01 21.22
September 23.43 17.37
October 20.51 11.70
November 17.28 4.05
December 16.31 1.86
     
Annual Sum or Average 20.43 11.20
Minimum of Months 15.22 -1.7
Maximum of Months 26.04 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.85 -1.7
February 22.29 2.70
March 22.74 6.07
April 23.83 11.58
May 24.15 14.61
June 24.32 19.78
July 24.39 24.54
August 24.38 21.22
September 24.32 17.37
October 23.93 11.70
November 22.53 4.05
December 22.05 1.86
     
Annual Sum or Average 23.40 11.20
Minimum of Months 21.85 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.75 2.70
March 21.99 6.07
April 23.32 11.58
May 23.97 14.61
June 24.30 19.78
July 24.39 24.54
August 24.33 21.22
September 24.16 17.37
October 23.03 11.70
November 21.90 4.05
December 21.71 1.86
     
Annual Sum or Average 23.05 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 SE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.88 -1.7
February 22.35 2.70
March 22.91 6.07
April 23.96 11.58
May 24.21 14.61
June 24.35 19.78
July 24.39 24.54
August 24.38 21.22
September 24.33 17.37
October 24.02 11.70
November 22.62 4.05
December 22.11 1.86
     
Annual Sum or Average 23.46 11.20
Minimum of Months 21.88 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 NE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.72 2.70
March 21.94 6.07
April 23.27 11.58
May 23.88 14.61
June 24.30 19.78
July 24.39 24.54
August 24.32 21.22
September 24.09 17.37
October 22.93 11.70
November 21.84 4.05
December 21.70 1.86
     
Annual Sum or Average 23.01 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.72 2.70
March 21.86 6.07
April 23.08 11.58
May 23.75 14.61
June 24.26 19.78
July 24.38 24.54
August 24.29 21.22
September 24.04 17.37
October 22.87 11.70
November 21.89 4.05
December 21.70 1.86
     
Annual Sum or Average 22.97 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.38 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 N2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.72 2.70
March 21.86 6.07
April 23.08 11.58
May 23.74 14.61
June 24.26 19.78
July 24.39 24.54
August 24.29 21.22
September 24.03 17.37
October 22.86 11.70
November 21.88 4.05
December 21.70 1.86
     
Annual Sum or Average 22.97 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.92 -1.7
February 22.45 2.70
March 22.91 6.07
April 23.90 11.58
May 24.11 14.61
June 24.30 19.78
July 24.37 24.54
August 24.36 21.22
September 24.33 17.37
October 24.09 11.70
November 22.71 4.05
December 22.22 1.86
     
Annual Sum or Average 23.48 11.20
Minimum of Months 21.92 -1.7
Maximum of Months 24.37 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 S2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.92 -1.7
February 22.46 2.70
March 22.94 6.07
April 23.92 11.58
May 24.12 14.61
June 24.31 19.78
July 24.37 24.54
August 24.36 21.22
September 24.33 17.37
October 24.10 11.70
November 22.73 4.05
December 22.23 1.86
     
Annual Sum or Average 23.49 11.20
Minimum of Months 21.92 -1.7
Maximum of Months 24.37 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F2 CORRIDOR

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.28 -1.7
February 22.09 2.70
March 22.76 6.07
April 24.44 11.58
May 25.10 14.61
June 26.11 19.78
July 26.62 24.54
August 26.29 21.22
September 25.76 17.37
October 24.39 11.70
November 22.36 4.05
December 21.69 1.86
     
Annual Sum or Average 24.08 11.20
Minimum of Months 21.28 -1.7
Maximum of Months 26.62 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.86 -1.7
February 22.33 2.70
March 22.83 6.07
April 23.93 11.58
May 24.23 14.61
June 24.32 19.78
July 24.39 24.54
August 24.38 21.22
September 24.32 17.37
October 24.02 11.70
November 22.61 4.05
December 22.09 1.86
     
Annual Sum or Average 23.45 11.20
Minimum of Months 21.86 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.77 2.70
March 22.02 6.07
April 23.46 11.58
May 24.10 14.61
June 24.30 19.78
July 24.39 24.54
August 24.34 21.22
September 24.17 17.37
October 23.17 11.70
November 21.96 4.05
December 21.71 1.86
     
Annual Sum or Average 23.10 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 SE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.84 -1.7
February 22.31 2.70
March 22.86 6.07
April 23.97 11.58
May 24.23 14.61
June 24.34 19.78
July 24.39 24.54
August 24.37 21.22
September 24.31 17.37
October 24.03 11.70
November 22.59 4.05
December 22.07 1.86
     
Annual Sum or Average 23.45 11.20
Minimum of Months 21.84 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 NE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.72 2.70
March 21.97 6.07
April 23.42 11.58
May 24.02 14.61
June 24.31 19.78
July 24.39 24.54
August 24.33 21.22
September 24.10 17.37
October 23.08 11.70
November 21.88 4.05
December 21.70 1.86
     
Annual Sum or Average 23.06 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.73 2.70
March 21.91 6.07
April 23.31 11.58
May 23.98 14.61
June 24.28 19.78
July 24.39 24.54
August 24.30 21.22
September 24.07 17.37
October 23.08 11.70
November 21.98 4.05
December 21.70 1.86
     
Annual Sum or Average 23.04 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 N2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.73 2.70
March 21.91 6.07
April 23.31 11.58
May 23.97 14.61
June 24.28 19.78
July 24.39 24.54
August 24.30 21.22
September 24.06 17.37
October 23.07 11.70
November 21.97 4.05
December 21.70 1.86
     
Annual Sum or Average 23.04 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.95 -1.7
February 22.57 2.70
March 23.10 6.07
April 24.04 11.58
May 24.23 14.61
June 24.32 19.78
July 24.37 24.54
August 24.36 21.22
September 24.34 17.37
October 24.21 11.70
November 22.86 4.05
December 22.32 1.86
     
Annual Sum or Average 23.56 11.20
Minimum of Months 21.95 -1.7
Maximum of Months 24.37 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 S2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.95 -1.7
February 22.57 2.70
March 23.11 6.07
April 24.05 11.58
May 24.24 14.61
June 24.32 19.78
July 24.37 24.54
August 24.36 21.22
September 24.34 17.37
October 24.21 11.70
November 22.86 4.05
December 22.32 1.86
     
Annual Sum or Average 23.56 11.20
Minimum of Months 21.95 -1.7
Maximum of Months 24.37 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F3 CORRIDOR

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.82 -1.7
February 22.59 2.70
March 23.25 6.07
April 24.97 11.58
May 25.63 14.61
June 26.31 19.78
July 26.72 24.54
August 26.42 21.22
September 25.97 17.37
October 24.87 11.70
November 22.88 4.05
December 22.18 1.86
     
Annual Sum or Average 24.47 11.20
Minimum of Months 21.82 -1.7
Maximum of Months 26.72 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.85 -1.7
February 22.31 2.70
March 22.81 6.07
April 23.91 11.58
May 24.24 14.61
June 24.31 19.78
July 24.39 24.54
August 24.38 21.22
September 24.32 17.37
October 24.02 11.70
November 22.61 4.05
December 22.08 1.86
     
Annual Sum or Average 23.44 11.20
Minimum of Months 21.85 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.77 2.70
March 22.01 6.07
April 23.46 11.58
May 24.12 14.61
June 24.29 19.78
July 24.40 24.54
August 24.33 21.22
September 24.16 17.37
October 23.19 11.70
November 21.98 4.05
December 21.71 1.86
     
Annual Sum or Average 23.10 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.40 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 SE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.83 -1.7
February 22.29 2.70
March 22.82 6.07
April 23.94 11.58
May 24.22 14.61
June 24.33 19.78
July 24.39 24.54
August 24.37 21.22
September 24.30 17.37
October 24.02 11.70
November 22.58 4.05
December 22.05 1.86
     
Annual Sum or Average 23.43 11.20
Minimum of Months 21.83 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 NE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.73 2.70
March 21.97 6.07
April 23.43 11.58
May 24.04 14.61
June 24.30 19.78
July 24.40 24.54
August 24.32 21.22
September 24.10 17.37
October 23.10 11.70
November 21.90 4.05
December 21.70 1.86
     
Annual Sum or Average 23.06 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.40 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.73 2.70
March 21.92 6.07
April 23.36 11.58
May 24.04 14.61
June 24.28 19.78
July 24.40 24.54
August 24.30 21.22
September 24.08 17.37
October 23.14 11.70
November 22.02 4.05
December 21.70 1.86
     
Annual Sum or Average 23.06 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.40 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 N2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.73 2.70
March 21.92 6.07
April 23.36 11.58
May 24.03 14.61
June 24.29 19.78
July 24.40 24.54
August 24.30 21.22
September 24.07 17.37
October 23.14 11.70
November 22.01 4.05
December 21.70 1.86
     
Annual Sum or Average 23.06 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.40 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.95 -1.7
February 22.58 2.70
March 23.11 6.07
April 24.06 11.58
May 24.26 14.61
June 24.31 19.78
July 24.37 24.54
August 24.36 21.22
September 24.35 17.37
October 24.22 11.70
November 22.88 4.05
December 22.33 1.86
     
Annual Sum or Average 23.57 11.20
Minimum of Months 21.95 -1.7
Maximum of Months 24.37 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 S2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.95 -1.7
February 22.58 2.70
March 23.12 6.07
April 24.06 11.58
May 24.26 14.61
June 24.32 19.78
July 24.37 24.54
August 24.36 21.22
September 24.35 17.37
October 24.22 11.70
November 22.88 4.05
December 22.33 1.86
     
Annual Sum or Average 23.57 11.20
Minimum of Months 21.95 -1.7
Maximum of Months 24.37 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F4 CORRIDOR

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.96 -1.7
February 22.73 2.70
March 23.38 6.07
April 25.13 11.58
May 25.80 14.61
June 26.40 19.78
July 26.80 24.54
August 26.50 21.22
September 26.07 17.37
October 25.02 11.70
November 23.04 4.05
December 22.31 1.86
     
Annual Sum or Average 24.61 11.20
Minimum of Months 21.96 -1.7
Maximum of Months 26.80 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.84 -1.7
February 22.30 2.70
March 22.78 6.07
April 23.89 11.58
May 24.23 14.61
June 24.30 19.78
July 24.39 24.54
August 24.38 21.22
September 24.32 17.37
October 24.01 11.70
November 22.60 4.05
December 22.07 1.86
     
Annual Sum or Average 23.43 11.20
Minimum of Months 21.84 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.77 2.70
March 22.01 6.07
April 23.44 11.58
May 24.11 14.61
June 24.28 19.78
July 24.40 24.54
August 24.33 21.22
September 24.15 17.37
October 23.18 11.70
November 21.98 4.05
December 21.71 1.86
     
Annual Sum or Average 23.10 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.40 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.83 -1.7
February 22.27 2.70
March 22.79 6.07
April 23.91 11.58
May 24.21 14.61
June 24.32 19.78
July 24.39 24.54
August 24.37 21.22
September 24.30 17.37
October 24.01 11.70
November 22.56 4.05
December 22.04 1.86
     
Annual Sum or Average 23.42 11.20
Minimum of Months 21.83 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.73 2.70
March 21.96 6.07
April 23.41 11.58
May 24.04 14.61
June 24.29 19.78
July 24.40 24.54
August 24.32 21.22
September 24.09 17.37
October 23.10 11.70
November 21.90 4.05
December 21.70 1.86
     
Annual Sum or Average 23.06 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.40 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.74 2.70
March 21.93 6.07
April 23.37 11.58
May 24.05 14.61
June 24.28 19.78
July 24.40 24.54
August 24.30 21.22
September 24.08 17.37
October 23.16 11.70
November 22.03 4.05
December 21.70 1.86
     
Annual Sum or Average 23.07 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.40 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.74 2.70
March 21.93 6.07
April 23.37 11.58
May 24.04 14.61
June 24.28 19.78
July 24.40 24.54
August 24.30 21.22
September 24.07 17.37
October 23.16 11.70
November 22.02 4.05
December 21.70 1.86
     
Annual Sum or Average 23.07 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.40 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.95 -1.7
February 22.57 2.70
March 23.10 6.07
April 24.05 11.58
May 24.26 14.61
June 24.31 19.78
July 24.37 24.54
August 24.36 21.22
September 24.34 17.37
October 24.22 11.70
November 22.89 4.05
December 22.34 1.86
     
Annual Sum or Average 23.57 11.20
Minimum of Months 21.95 -1.7
Maximum of Months 24.37 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.95 -1.7
February 22.57 2.70
March 23.11 6.07
April 24.05 11.58
May 24.26 14.61
June 24.31 19.78
July 24.37 24.54
August 24.36 21.22
September 24.34 17.37
October 24.22 11.70
November 22.89 4.05
December 22.34 1.86
     
Annual Sum or Average 23.57 11.20
Minimum of Months 21.95 -1.7
Maximum of Months 24.37 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.55 -1.7
February 23.30 2.70
March 23.94 6.07
April 25.67 11.58
May 26.35 14.61
June 26.93 19.78
July 27.33 24.54
August 27.03 21.22
September 26.60 17.37
October 25.58 11.70
November 23.62 4.05
December 22.89 1.86
     
Annual Sum or Average 25.16 11.20
Minimum of Months 22.55 -1.7
Maximum of Months 27.33 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.82 -1.7
February 22.25 2.70
March 22.68 6.07
April 23.82 11.58
May 24.19 14.61
June 24.28 19.78
July 24.39 24.54
August 24.37 21.22
September 24.30 17.37
October 23.94 11.70
November 22.54 4.05
December 22.04 1.86
     
Annual Sum or Average 23.39 11.20
Minimum of Months 21.82 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.76 2.70
March 21.96 6.07
April 23.34 11.58
May 24.04 14.61
June 24.26 19.78
July 24.39 24.54
August 24.31 21.22
September 24.10 17.37
October 23.07 11.70
November 21.93 4.05
December 21.71 1.86
     
Annual Sum or Average 23.06 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 SE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.81 -1.7
February 22.22 2.70
March 22.70 6.07
April 23.84 11.58
May 24.17 14.61
June 24.31 19.78
July 24.39 24.54
August 24.36 21.22
September 24.27 17.37
October 23.94 11.70
November 22.50 4.05
December 22.01 1.86
     
Annual Sum or Average 23.38 11.20
Minimum of Months 21.81 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 NE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.72 2.70
March 21.92 6.07
April 23.31 11.58
May 23.97 14.61
June 24.26 19.78
July 24.40 24.54
August 24.30 21.22
September 24.03 17.37
October 22.98 11.70
November 21.87 4.05
December 21.70 1.86
     
Annual Sum or Average 23.02 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.40 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.73 2.70
March 21.89 6.07
April 23.26 11.58
May 23.98 14.61
June 24.25 19.78
July 24.40 24.54
August 24.28 21.22
September 24.02 17.37
October 23.04 11.70
November 21.98 4.05
December 21.70 1.86
     
Annual Sum or Average 23.03 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.40 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 N2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.73 2.70
March 21.89 6.07
April 23.26 11.58
May 23.97 14.61
June 24.25 19.78
July 24.40 24.54
August 24.28 21.22
September 24.01 17.37
October 23.04 11.70
November 21.98 4.05
December 21.70 1.86
     
Annual Sum or Average 23.02 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.40 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.92 -1.7
February 22.49 2.70
March 23.00 6.07
April 23.98 11.58
May 24.22 14.61
June 24.29 19.78
July 24.37 24.54
August 24.35 21.22
September 24.32 17.37
October 24.17 11.70
November 22.82 4.05
December 22.28 1.86
     
Annual Sum or Average 23.52 11.20
Minimum of Months 21.92 -1.7
Maximum of Months 24.37 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 S2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.92 -1.7
February 22.49 2.70
March 23.00 6.07
April 23.99 11.58
May 24.22 14.61
June 24.29 19.78
July 24.37 24.54
August 24.35 21.22
September 24.32 17.37
October 24.18 11.70
November 22.82 4.05
December 22.28 1.86
     
Annual Sum or Average 23.52 11.20
Minimum of Months 21.92 -1.7
Maximum of Months 24.37 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F6 CORRIDOR

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.92 -1.7
February 22.66 2.70
March 23.29 6.07
April 25.03 11.58
May 25.74 14.61
June 26.36 19.78
July 26.79 24.54
August 26.47 21.22
September 26.01 17.37
October 24.94 11.70
November 22.98 4.05
December 22.26 1.86
     
Annual Sum or Average 24.55 11.20
Minimum of Months 21.92 -1.7
Maximum of Months 26.79 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.81 -1.7
February 22.21 2.70
March 22.61 6.07
April 23.75 11.58
May 24.16 14.61
June 24.27 19.78
July 24.39 24.54
August 24.36 21.22
September 24.28 17.37
October 23.89 11.70
November 22.49 4.05
December 22.01 1.86
     
Annual Sum or Average 23.36 11.20
Minimum of Months 21.81 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.75 2.70
March 21.93 6.07
April 23.27 11.58
May 23.99 14.61
June 24.24 19.78
July 24.39 24.54
August 24.30 21.22
September 24.06 17.37
October 22.99 11.70
November 21.90 4.05
December 21.71 1.86
     
Annual Sum or Average 23.03 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 SE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.80 -1.7
February 22.18 2.70
March 22.63 6.07
April 23.78 11.58
May 24.13 14.61
June 24.29 19.78
July 24.39 24.54
August 24.35 21.22
September 24.25 17.37
October 23.89 11.70
November 22.46 4.05
December 21.98 1.86
     
Annual Sum or Average 23.35 11.20
Minimum of Months 21.80 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 NE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.72 2.70
March 21.89 6.07
April 23.23 11.58
May 23.92 14.61
June 24.24 19.78
July 24.40 24.54
August 24.28 21.22
September 23.98 17.37
October 22.89 11.70
November 21.84 4.05
December 21.70 1.86
     
Annual Sum or Average 22.99 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.40 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.73 2.70
March 21.86 6.07
April 23.18 11.58
May 23.92 14.61
June 24.23 19.78
July 24.40 24.54
August 24.26 21.22
September 23.98 17.37
October 22.95 11.70
November 21.94 4.05
December 21.70 1.86
     
Annual Sum or Average 22.99 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.40 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 N2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.72 2.70
March 21.86 6.07
April 23.18 11.58
May 23.91 14.61
June 24.23 19.78
July 24.40 24.54
August 24.26 21.22
September 23.97 17.37
October 22.94 11.70
November 21.94 4.05
December 21.70 1.86
     
Annual Sum or Average 22.99 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.40 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.90 -1.7
February 22.44 2.70
March 22.91 6.07
April 23.93 11.58
May 24.19 14.61
June 24.28 19.78
July 24.37 24.54
August 24.34 21.22
September 24.31 17.37
October 24.13 11.70
November 22.77 4.05
December 22.23 1.86
     
Annual Sum or Average 23.49 11.20
Minimum of Months 21.90 -1.7
Maximum of Months 24.37 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 S2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.90 -1.7
February 22.44 2.70
March 22.92 6.07
April 23.93 11.58
May 24.19 14.61
June 24.28 19.78
July 24.37 24.54
August 24.34 21.22
September 24.31 17.37
October 24.14 11.70
November 22.76 4.05
December 22.23 1.86
     
Annual Sum or Average 23.49 11.20
Minimum of Months 21.90 -1.7
Maximum of Months 24.37 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F7 CORRIDOR

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.78 -1.7
February 22.51 2.70
March 23.12 6.07
April 24.86 11.58
May 25.60 14.61
June 26.26 19.78
July 26.72 24.54
August 26.38 21.22
September 25.89 17.37
October 24.78 11.70
November 22.82 4.05
December 22.12 1.86
     
Annual Sum or Average 24.41 11.20
Minimum of Months 21.78 -1.7
Maximum of Months 26.72 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.80 -1.7
February 22.18 2.70
March 22.56 6.07
April 23.70 11.58
May 24.12 14.61
June 24.26 19.78
July 24.39 24.54
August 24.35 21.22
September 24.26 17.37
October 23.83 11.70
November 22.44 4.05
December 21.99 1.86
     
Annual Sum or Average 23.33 11.20
Minimum of Months 21.80 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.75 2.70
March 21.91 6.07
April 23.20 11.58
May 23.94 14.61
June 24.23 19.78
July 24.39 24.54
August 24.29 21.22
September 24.03 17.37
October 22.92 11.70
November 21.87 4.05
December 21.71 1.86
     
Annual Sum or Average 23.00 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 SE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.79 -1.7
February 22.15 2.70
March 22.58 6.07
April 23.73 11.58
May 24.10 14.61
June 24.28 19.78
July 24.39 24.54
August 24.35 21.22
September 24.23 17.37
October 23.84 11.70
November 22.41 4.05
December 21.96 1.86
     
Annual Sum or Average 23.32 11.20
Minimum of Months 21.79 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 NE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.72 2.70
March 21.87 6.07
April 23.16 11.58
May 23.87 14.61
June 24.22 19.78
July 24.40 24.54
August 24.27 21.22
September 23.94 17.37
October 22.82 11.70
November 21.82 4.05
December 21.70 1.86
     
Annual Sum or Average 22.96 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.40 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.72 2.70
March 21.84 6.07
April 23.11 11.58
May 23.86 14.61
June 24.21 19.78
July 24.39 24.54
August 24.25 21.22
September 23.94 17.37
October 22.87 11.70
November 21.90 4.05
December 21.70 1.86
     
Annual Sum or Average 22.96 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 N2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.72 2.70
March 21.84 6.07
April 23.11 11.58
May 23.85 14.61
June 24.21 19.78
July 24.40 24.54
August 24.25 21.22
September 23.93 17.37
October 22.86 11.70
November 21.90 4.05
December 21.70 1.86
     
Annual Sum or Average 22.96 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.40 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.88 -1.7
February 22.39 2.70
March 22.84 6.07
April 23.88 11.58
May 24.16 14.61
June 24.27 19.78
July 24.37 24.54
August 24.34 21.22
September 24.29 17.37
October 24.09 11.70
November 22.70 4.05
December 22.19 1.86
     
Annual Sum or Average 23.45 11.20
Minimum of Months 21.88 -1.7
Maximum of Months 24.37 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 S2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.88 -1.7
February 22.39 2.70
March 22.84 6.07
April 23.88 11.58
May 24.16 14.61
June 24.27 19.78
July 24.37 24.54
August 24.34 21.22
September 24.29 17.37
October 24.09 11.70
November 22.70 4.05
December 22.19 1.86
     
Annual Sum or Average 23.45 11.20
Minimum of Months 21.88 -1.7
Maximum of Months 24.37 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F8 CORRIDOR

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.69 -1.7
February 22.42 2.70
March 23.03 6.07
April 24.77 11.58
May 25.52 14.61
June 26.23 19.78
July 26.72 24.54
August 26.36 21.22
September 25.83 17.37
October 24.67 11.70
November 22.71 4.05
December 22.03 1.86
     
Annual Sum or Average 24.34 11.20
Minimum of Months 21.69 -1.7
Maximum of Months 26.72 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.79 -1.7
February 22.14 2.70
March 22.49 6.07
April 23.62 11.58
May 24.07 14.61
June 24.24 19.78
July 24.39 24.54
August 24.34 21.22
September 24.23 17.37
October 23.73 11.70
November 22.37 4.05
December 21.95 1.86
     
Annual Sum or Average 23.29 11.20
Minimum of Months 21.79 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.74 2.70
March 21.90 6.07
April 23.14 11.58
May 23.88 14.61
June 24.21 19.78
July 24.39 24.54
August 24.27 21.22
September 23.97 17.37
October 22.84 11.70
November 21.84 4.05
December 21.70 1.86
     
Annual Sum or Average 22.97 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 SE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.77 -1.7
February 22.11 2.70
March 22.52 6.07
April 23.65 11.58
May 24.05 14.61
June 24.26 19.78
July 24.39 24.54
August 24.34 21.22
September 24.20 17.37
October 23.74 11.70
November 22.34 4.05
December 21.93 1.86
     
Annual Sum or Average 23.28 11.20
Minimum of Months 21.77 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 NE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.71 2.70
March 21.85 6.07
April 23.09 11.58
May 23.81 14.61
June 24.20 19.78
July 24.40 24.54
August 24.25 21.22
September 23.88 17.37
October 22.74 11.70
November 21.80 4.05
December 21.70 1.86
     
Annual Sum or Average 22.94 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.40 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.72 2.70
March 21.83 6.07
April 23.05 11.58
May 23.79 14.61
June 24.19 19.78
July 24.39 24.54
August 24.23 21.22
September 23.89 17.37
October 22.78 11.70
November 21.86 4.05
December 21.70 1.86
     
Annual Sum or Average 22.93 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 N2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.72 2.70
March 21.83 6.07
April 23.05 11.58
May 23.78 14.61
June 24.19 19.78
July 24.39 24.54
August 24.23 21.22
September 23.88 17.37
October 22.77 11.70
November 21.85 4.05
December 21.70 1.86
     
Annual Sum or Average 22.93 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.39 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.86 -1.7
February 22.32 2.70
March 22.73 6.07
April 23.79 11.58
May 24.11 14.61
June 24.25 19.78
July 24.37 24.54
August 24.33 21.22
September 24.26 17.37
October 23.99 11.70
November 22.60 4.05
December 22.12 1.86
     
Annual Sum or Average 23.40 11.20
Minimum of Months 21.86 -1.7
Maximum of Months 24.37 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 S2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.86 -1.7
February 22.31 2.70
March 22.74 6.07
April 23.79 11.58
May 24.11 14.61
June 24.25 19.78
July 24.37 24.54
August 24.33 21.22
September 24.26 17.37
October 23.99 11.70
November 22.60 4.05
December 22.12 1.86
     
Annual Sum or Average 23.40 11.20
Minimum of Months 21.86 -1.7
Maximum of Months 24.37 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: F9 CORRIDOR

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.51 -1.7
February 22.26 2.70
March 22.89 6.07
April 24.66 11.58
May 25.46 14.61
June 26.26 19.78
July 26.80 24.54
August 26.39 21.22
September 25.79 17.37
October 24.52 11.70
November 22.52 4.05
December 21.85 1.86
     
Annual Sum or Average 24.25 11.20
Minimum of Months 21.51 -1.7
Maximum of Months 26.80 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.83 -1.7
February 22.16 2.70
March 22.43 6.07
April 23.31 11.58
May 23.82 14.61
June 24.12 19.78
July 24.35 24.54
August 24.20 21.22
September 24.02 17.37
October 23.34 11.70
November 22.26 4.05
December 21.96 1.86
     
Annual Sum or Average 23.16 11.20
Minimum of Months 21.83 -1.7
Maximum of Months 24.35 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.80 2.70
March 22.02 6.07
April 22.99 11.58
May 23.67 14.61
June 24.09 19.78
July 24.36 24.54
August 24.11 21.22
September 23.76 17.37
October 22.73 11.70
November 21.85 4.05
December 21.72 1.86
     
Annual Sum or Average 22.91 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.36 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.81 -1.7
February 22.13 2.70
March 22.45 6.07
April 23.34 11.58
May 23.82 14.61
June 24.15 19.78
July 24.37 24.54
August 24.21 21.22
September 23.99 17.37
October 23.35 11.70
November 22.24 4.05
December 21.94 1.86
     
Annual Sum or Average 23.16 11.20
Minimum of Months 21.81 -1.7
Maximum of Months 24.37 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.75 2.70
March 21.96 6.07
April 22.97 11.58
May 23.60 14.61
June 24.07 19.78
July 24.36 24.54
August 24.09 21.22
September 23.69 17.37
October 22.65 11.70
November 21.81 4.05
December 21.70 1.86
     
Annual Sum or Average 22.87 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.36 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.75 2.70
March 21.94 6.07
April 22.94 11.58
May 23.61 14.61
June 24.08 19.78
July 24.35 24.54
August 24.09 21.22
September 23.70 17.37
October 22.65 11.70
November 21.83 4.05
December 21.70 1.86
     
Annual Sum or Average 22.87 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.35 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -1.7
February 21.75 2.70
March 21.94 6.07
April 22.94 11.58
May 23.61 14.61
June 24.08 19.78
July 24.34 24.54
August 24.09 21.22
September 23.69 17.37
October 22.65 11.70
November 21.83 4.05
December 21.70 1.86
     
Annual Sum or Average 22.87 11.20
Minimum of Months 21.70 -1.7
Maximum of Months 24.34 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.89 -1.7
February 22.26 2.70
March 22.57 6.07
April 23.47 11.58
May 23.90 14.61
June 24.15 19.78
July 24.34 24.54
August 24.23 21.22
September 24.09 17.37
October 23.57 11.70
November 22.41 4.05
December 22.04 1.86
     
Annual Sum or Average 23.25 11.20
Minimum of Months 21.89 -1.7
Maximum of Months 24.34 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.89 -1.7
February 22.26 2.70
March 22.57 6.07
April 23.48 11.58
May 23.91 14.61
June 24.16 19.78
July 24.34 24.54
August 24.24 21.22
September 24.09 17.37
October 23.57 11.70
November 22.41 4.05
December 22.04 1.86
     
Annual Sum or Average 23.25 11.20
Minimum of Months 21.89 -1.7
Maximum of Months 24.34 24.54



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2015-09-09 19:00:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.34 -1.7
February 22.25 2.70
March 23.04 6.07
April 24.97 11.58
May 25.92 14.61
June 26.94 19.78
July 27.66 24.54
August 27.05 21.22
September 26.22 17.37
October 24.63 11.70
November 22.43 4.05
December 21.72 1.86
     
Annual Sum or Average 24.52 11.20
Minimum of Months 21.34 -1.7
Maximum of Months 27.66 24.54



Table of Contents

Report: COMPONENTS OF PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2015-09-09 19:00:31

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY {AT MAX/MIN} [W] HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY {AT MAX/MIN} [W]
January 0.262606E+12 139736.770 10-JAN-19:00 14401.373 51749.961 23798.643 35696.000 0.000 10364.000 1965.768 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
February 0.216350E+12 121093.789 13-FEB-19:00 14401.373 51749.961 23798.643 17053.019 0.000 10364.000 1965.768 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
March 0.227100E+12 126806.700 31-MAR-16:15 11327.174 57142.088 23798.643 0.000 29554.040 0.000 1965.768 1023.790 0.000 0.000 0.000 0.000 0.000 0.000 0.000
April 0.217706E+12 154844.220 13-APR-16:30 11327.174 57142.088 23798.643 0.000 56870.102 0.000 1965.768 1745.287 0.000 0.000 0.000 0.000 0.000 0.000 0.000
May 0.232961E+12 161472.681 04-MAY-17:30 13120.457 57042.023 23798.643 0.000 61612.694 0.000 1965.768 1945.088 0.000 0.000 0.000 0.000 0.000 0.000 0.000
June 0.263262E+12 168178.770 22-JUN-17:15 13120.457 57042.023 23798.643 0.000 68047.407 0.000 1965.768 2216.660 0.000 0.000 0.000 0.000 0.000 0.000 0.000
July 0.305147E+12 171034.841 31-JUL-17:00 13120.457 57042.023 23798.643 0.000 70644.804 0.000 1965.768 2475.137 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 0.283288E+12 170622.957 08-AUG-17:15 13120.457 57042.023 23798.643 0.000 70518.397 0.000 1965.768 2189.857 0.000 0.000 0.000 0.000 0.000 0.000 0.000
September 0.249863E+12 164581.833 08-SEP-17:15 13120.457 57042.023 23798.643 0.000 64658.879 0.000 1965.768 2008.251 0.000 0.000 0.000 0.000 0.000 0.000 0.000
October 0.231091E+12 162147.018 01-OCT-17:15 13120.457 57042.023 23798.643 0.000 62241.618 0.000 1965.768 1990.698 0.000 0.000 0.000 0.000 0.000 0.000 0.000
November 0.229905E+12 133920.814 23-NOV-18:15 13120.457 57042.023 23798.643 25642.111 0.000 10364.000 1965.768 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
December 0.250662E+12 147715.648 23-DEC-18:00 13120.457 57042.023 23798.643 39436.748 0.000 10364.000 1965.768 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
                                     
Annual Sum or Average 0.296994E+13                     0.000 0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.216350E+12 121093.789   11327.174 51749.961 23798.643 0.000 0.000 0.000 1965.768 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.305147E+12 171034.841   14401.373 57142.088 23798.643 39436.748 70644.804 10364.000 1965.768 2475.137 0.000 0.000 0.000 0.000 0.000 0.000 0.000



Table of Contents

Report: COMPONENTS OF PEAK GAS DEMAND

For: Meter

Timestamp: 2015-09-09 19:00:31

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC [Invalid/Undefined] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT {AT MAX/MIN} [W] WATERSYSTEMS:GAS {AT MAX/MIN} [W] WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] HEATING:GAS {AT MAX/MIN} [W]
January 0.303153E+12 267957.603 04-JAN-08:15 0.000 0.000 0.000 267957.603 81201.356 81201.356 186756.247
February 0.186941E+12 194383.791 15-FEB-10:00 0.000 0.000 0.000 194383.791 73643.478 73643.478 120740.313
March 0.154841E+12 166511.067 11-MAR-06:15 0.000 0.000 0.000 166511.067 68345.559 68345.559 98165.507
April 0.107252E+12 141063.680 08-APR-05:30 0.000 0.000 0.000 141063.680 76139.244 76139.244 64924.436
May 0.986851E+11 79038.074 02-MAY-06:00 0.000 0.000 0.000 79038.074 79038.074 79038.074 0.000
June 0.890697E+11 76557.588 02-JUN-06:00 0.000 0.000 0.000 76557.588 76557.588 76557.588 0.000
July 0.872850E+11 74642.089 01-JUL-06:45 0.000 0.000 0.000 74642.089 74642.089 74642.089 0.000
August 0.856397E+11 73643.506 31-AUG-06:45 0.000 0.000 0.000 73643.506 73643.506 73643.506 0.000
September 0.848155E+11 74748.612 29-SEP-06:45 0.000 0.000 0.000 74748.612 74748.612 74748.612 0.000
October 0.943345E+11 121879.495 26-OCT-07:15 0.000 0.000 0.000 121879.495 75941.551 75941.551 45937.944
November 0.174059E+12 201952.020 24-NOV-06:30 0.000 0.000 0.000 201952.020 68342.665 68342.665 133609.356
December 0.243482E+12 268387.144 28-DEC-08:15 0.000 0.000 0.000 268387.144 80520.398 80520.398 187866.747
                     
Annual Sum or Average 0.170956E+13     0.000 0.000 0.000        
Minimum of Months 0.848155E+11 73643.506   0.000 0.000 0.000 73643.506 68342.665 68342.665 0.000
Maximum of Months 0.303153E+12 268387.144   0.000 0.000 0.000 268387.144 81201.356 81201.356 187866.747