Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:48

Tabular Output Report in Format: HTML

Building: Mid-Rise Apartment

Environment: Salem Mcnary Field OR USA TMY3 WMO#=726940

Simulation Timestamp: 2015-09-09 18:48:09


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2015-09-09 18:48:09

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 1615.80 515.47 572.17
Net Site Energy 1615.80 515.47 572.17
Total Source Energy 4636.33 1479.07 1641.77
Net Source Energy 4636.33 1479.07 1641.77


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 3134.61
Net Conditioned Building Area 2823.98
Unconditioned Building Area 310.64


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 0.00 230.87 0.00 0.00 0.00 0.00
Cooling 76.72 0.00 0.00 0.00 0.00 0.00
Interior Lighting 118.46 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 40.10 0.00 0.00 0.00 0.00 0.00
Interior Equipment 517.65 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 229.15 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 402.84 0.00 0.00 0.00 0.00 1874.72
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 1384.93 230.87 0.00 0.00 0.00 1874.72
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating General 0.00 230.87 0.00 0.00 0.00 0.00
Cooling General 76.72 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 96.36 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 22.11 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 40.10 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 517.65 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 229.15 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 402.84 0.00 0.00 0.00 0.00 1874.72
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 56.15 0.00 0.00 0.00 0.00 0.00
HVAC 250.96 81.75 0.00 0.00 0.00 0.66
Other 183.31 0.00 0.00 0.00 0.00 0.00
Total 490.42 81.75 0.00 0.00 0.00 0.66


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 50.59 0.00 0.00 0.00 0.00 0.00
HVAC 226.09 73.65 0.00 0.00 0.00 0.60
Other 165.14 0.00 0.00 0.00 0.00 0.00
Total 441.82 73.65 0.00 0.00 0.00 0.60


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 1384.93 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 1384.93 100.00
     
Total On-Site and Utility Electric Sources 1384.93 100.00
Total Electricity End Uses 1384.93 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 1874.72 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 1874.72 100.00
Total Water End Uses 1874.72 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 79.75
Time Setpoint Not Met During Occupied Cooling 17.50
Time Not Comfortable Based on Simple ASHRAE 55-2004 580.75


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |

PEAK ELECTRICAL DEMAND

| Meter |

PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2015-09-09 18:48:09

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:48
RunPeriod Salem Mcnary Field OR USA TMY3 WMO#=726940
Weather File Salem Mcnary Field OR USA TMY3 WMO#=726940
Latitude [deg] 44.90
Longitude [deg] -123.0
Elevation [m] 60.00
Time Zone -8.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1542.04 564.80 206.22 564.80 206.22
Window Opening Area [m2] 306.92 112.97 37.16 112.97 43.82
Window-Wall Ratio [%] 19.90 20.00 18.02 20.00 21.25


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1501.17 564.80 185.79 564.80 185.79
Window Opening Area [m2] 300.26 112.97 37.16 112.97 37.16
Window-Wall Ratio [%] 20.00 20.00 20.00 20.00 20.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
OFFICE 88.25 Yes Yes 268.97 1.00 58.52 11.71 26.1977 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
M SW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 3.6746 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 3.6746 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 3.6746 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 3.6746 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 3.6746 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 3.6746 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 3.6746 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 3.6746 35.30 6.6700
T SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 1.11 5.9540   0.0000
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 3.32 5.9540   208.8202
M CORRIDOR 77.66 No Yes 236.69 2.00 10.22 1.11 5.9540   0.0000
Total 3134.61     9553.84   1542.04 306.92 4.5346 39.93 11.1825
Conditioned Total 2823.98     8607.06   1501.17 300.26 4.3785 35.97 6.6700
Unconditioned Total 310.64     946.78   40.87 6.66 5.9540   52.2051
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 18:48:09

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 18-JUL-16:15 20-DEC-04:00 - - - 01-JAN-07:15
Heating 0.00 78565.15 0.00 0.00 0.00 0.00
Cooling 23107.30 0.00 0.00 0.00 0.00 0.00
Interior Lighting 4276.26 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 26730.99 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 7266.23 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 22867.33 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 84248.10 78565.15 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating General 0.00 78565.15 0.00 0.00 0.00 0.00
Cooling General 23107.30 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 3538.13 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 738.12 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 26730.99 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 7266.23 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 22867.33 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 18:48:09

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 0.00 250.27 0.00 0.00 0.00
Cooling 242.98 0.00 0.00 0.00 0.00
Interior Lighting 375.17 0.00 0.00 0.00 0.00
Exterior Lighting 127.00 0.00 0.00 0.00 0.00
Interior Equipment 1639.40 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 725.71 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 1275.80 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 4386.06 250.27 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 88.62 0.00 0.00 0.00
Cooling 86.04 0.00 0.00 0.00 0.00
Interior Lighting 132.85 0.00 0.00 0.00 0.00
Exterior Lighting 44.97 0.00 0.00 0.00 0.00
Interior Equipment 580.53 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 256.98 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 451.77 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1553.15 88.62 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 88.62 0.00 0.00 0.00
Cooling 86.04 0.00 0.00 0.00 0.00
Interior Lighting 132.85 0.00 0.00 0.00 0.00
Exterior Lighting 44.97 0.00 0.00 0.00 0.00
Interior Equipment 580.53 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 256.98 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 451.77 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1553.15 88.62 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2015-09-09 18:48:09

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB -5.60 0.00 -5.60 Wetbulb [C] 2.10 0.00
SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 33.30 15.40 19.40 Wetbulb [C] 4.30 0.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2015-09-09 18:48:09

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
M WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 46.45 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 46.45 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 46.45 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 46.45 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
T WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.30 0.269 0.283 77.66 180.00 0.00  
G WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 90.00 180.00  
M WWALL C RES_EXT_WALL 0.30 0.363 0.384 10.22 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.363 0.384 10.22 90.00 90.00 E


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW1 S SWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL SWA 180.00 90.00 S
GWINDOW1 W SWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G WWALL SWA 270.00 90.00 W
GWINDOW1 N NWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL NWA 0.00 90.00 N
GWINDOW1 W NWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G WWALL NWA 270.00 90.00 W
GWINDOW1 S SEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL SEA 180.00 90.00 S
GWINDOW1 E SEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G EWALL SEA 90.00 90.00 E
GWINDOW1 N NEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL NEA 0.00 90.00 N
GWINDOW1 E NEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G EWALL NEA 90.00 90.00 E
GWINDOW1 N N1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL N1A 0.00 90.00 N
GWINDOW1 N N2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL N2A 0.00 90.00 N
GWINDOW1 S S1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL S1A 180.00 90.00 S
GWINDOW1 S S2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL S2A 180.00 90.00 S
MWINDOW1 W SWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M WWALL SWA 270.00 90.00 W
MWINDOW1 S SWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL SWA 180.00 90.00 S
MWINDOW1 N NWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL NWA 0.00 90.00 N
MWINDOW1 W NWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M WWALL NWA 270.00 90.00 W
MWINDOW1 E SEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M EWALL SEA 90.00 90.00 E
MWINDOW1 S SEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL SEA 180.00 90.00 S
MWINDOW1 N NEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL NEA 0.00 90.00 N
MWINDOW1 E NEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M EWALL NEA 90.00 90.00 E
MWINDOW1 N N1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL N1A 0.00 90.00 N
MWINDOW1 N N2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL N2A 0.00 90.00 N
MWINDOW1 S S1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL S1A 180.00 90.00 S
MWINDOW1 S S2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL S2A 180.00 90.00 S
TWINDOW1 W SWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T WWALL SWA 270.00 90.00 W
TWINDOW1 S SWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL SWA 180.00 90.00 S
TWINDOW1 N NWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL NWA 0.00 90.00 N
TWINDOW1 W NWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T WWALL NWA 270.00 90.00 W
TWINDOW1 E SEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T EWALL SEA 90.00 90.00 E
TWINDOW1 S SEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL SEA 180.00 90.00 S
TWINDOW1 N NEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL NEA 0.00 90.00 N
TWINDOW1 E NEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T EWALL NEA 90.00 90.00 E
TWINDOW1 N N1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL N1A 0.00 90.00 N
TWINDOW1 N N2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL N2A 0.00 90.00 N
TWINDOW1 S S1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL S1A 180.00 90.00 S
TWINDOW1 S S2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL S2A 180.00 90.00 S
TWINDOW14 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No T EWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.52_SHGC_0.40 3.32 0.00 0.00 3.32 3.32 2.653 0.426 0.308     No G EWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 2.23 2.653 0.426 0.308     No M EWALL C 270.00 90.00 W
Total or Average           306.92 2.653 0.426 0.308              
North Total or Average           112.97 2.653 0.426 0.308              
Non-North Total or Average           193.95 2.653 0.426 0.308              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2015-09-09 18:48:09

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2015-09-09 18:48:09

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
LIGHTING_HARDWIRED_GSW G SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GNW G NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_OFFICE OFFICE 13.0989 88.25 1155.96 GeneralLights LTG_OFF_SCH 62.17 168.00 60.95 0.0000 Y 13.23
LIGHTING_HARDWIRED_GNE G NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GN1 G N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GN2 G N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GS1 G S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GS2 G S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MSW M SW APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MNW M NW APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MSE M SE APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MNE M NE APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MN1 M N1 APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MN2 M N2 APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MS1 M S1 APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MS2 M S2 APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TSW T SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TNW T NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TSE T SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TNE T NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TN1 T N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TN2 T N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TS1 T S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TS2 T S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GC G CORRIDOR 5.9540 77.66 462.39 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 14.58
LIGHTING_HARDWIRED_MC M CORRIDOR 5.9540 155.32 924.77 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 14.58
LIGHTING_HARDWIRED_TC T CORRIDOR 5.9540 77.66 462.39 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 14.58
LIGHTING_PLUGIN_GSW G SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_GNW G NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_OFFICE OFFICE 13.0989 88.25 1155.96 GeneralLights-plugin LTG_OFF_SCH 62.17 168.00 60.95 0.0000 Y 13.23
LIGHTING_PLUGIN_GNE G NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_GN1 G N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_GN2 G N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_GS1 G S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_GS2 G S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MSW M SW APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MNW M NW APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MSE M SE APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MNE M NE APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MN1 M N1 APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MN2 M N2 APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MS1 M S1 APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MS2 M S2 APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TSW T SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TNW T NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TSE T SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TNE T NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TN1 T N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TN2 T N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TS1 T S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TS2 T S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
Interior Lighting Total   2.3855 5958.59 14214.30               95.19


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 2553.00 AstronomicalClock -   83.68 83.68 40.10
Exterior Lighting Total 2553.00           40.10



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2015-09-09 18:48:09

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
None          


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
SPLIT GSW COOLING COIL Coil:Cooling:DX:SingleSpeed   3245.56 2536.40 709.16 0.78 3.91    
SPLIT GNW COOLING COIL Coil:Cooling:DX:SingleSpeed   2507.69 1987.76 519.92 0.79 3.91    
SPLIT OFFICE COOLING COIL Coil:Cooling:DX:SingleSpeed   7684.46 6137.24 1547.23 0.80 3.91    
SPLIT GNE COOLING COIL Coil:Cooling:DX:SingleSpeed   1736.80 1360.14 376.66 0.78 3.91    
SPLIT GN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   1322.93 1035.81 287.12 0.78 3.91    
SPLIT GN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   1305.08 1021.18 283.91 0.78 3.91    
SPLIT GS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   2388.64 1833.85 554.79 0.77 3.91    
SPLIT GS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   2438.77 1874.71 564.06 0.77 3.91    
SPLIT MSW COOLING COIL Coil:Cooling:DX:SingleSpeed   8582.99 6808.54 1774.45 0.79 3.91    
SPLIT MNW COOLING COIL Coil:Cooling:DX:SingleSpeed   6775.78 5411.51 1364.27 0.80 3.91    
SPLIT MSE COOLING COIL Coil:Cooling:DX:SingleSpeed   8143.90 6399.50 1744.40 0.79 3.91    
SPLIT MNE COOLING COIL Coil:Cooling:DX:SingleSpeed   5072.00 4038.80 1033.20 0.80 3.91    
SPLIT MN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   3783.21 3006.79 776.42 0.79 3.91    
SPLIT MN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   3752.42 2981.42 771.00 0.79 3.91    
SPLIT MS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   6540.08 5091.66 1448.42 0.78 3.91    
SPLIT MS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   6557.94 5106.20 1451.74 0.78 3.91    
SPLIT TSW COOLING COIL Coil:Cooling:DX:SingleSpeed   5777.49 4594.72 1182.76 0.80 3.91    
SPLIT TNW COOLING COIL Coil:Cooling:DX:SingleSpeed   4559.44 3641.42 918.02 0.80 3.91    
SPLIT TSE COOLING COIL Coil:Cooling:DX:SingleSpeed   5438.17 4304.37 1133.80 0.79 3.91    
SPLIT TNE COOLING COIL Coil:Cooling:DX:SingleSpeed   3786.67 2960.48 826.19 0.78 3.91    
SPLIT TN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   2986.63 2318.59 668.04 0.78 3.91    
SPLIT TN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   2984.28 2316.70 667.58 0.78 3.91    
SPLIT TS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   4602.08 3628.31 973.76 0.79 3.91    
SPLIT TS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   4614.03 3638.00 976.03 0.79 3.91    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
SPLIT GSW COOLING COIL Coil:Cooling:DX:SingleSpeed 3099.0 3.16 10.77 11.20 10.52
SPLIT GNW COOLING COIL Coil:Cooling:DX:SingleSpeed 2390.9 3.14 10.71 11.13 10.43
SPLIT OFFICE COOLING COIL Coil:Cooling:DX:SingleSpeed 7320.7 3.13 10.67 11.09 10.38
SPLIT GNE COOLING COIL Coil:Cooling:DX:SingleSpeed 1658.0 3.15 10.76 11.19 10.51
SPLIT GN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 1262.9 3.15 10.76 11.19 10.51
SPLIT GN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 1246.0 3.16 10.77 11.19 10.52
SPLIT GS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 2284.9 3.18 10.85 11.29 10.64
SPLIT GS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 2332.6 3.18 10.85 11.28 10.63
SPLIT MSW COOLING COIL Coil:Cooling:DX:SingleSpeed 8182.5 3.14 10.70 11.12 10.42
SPLIT MNW COOLING COIL Coil:Cooling:DX:SingleSpeed 6455.0 3.13 10.67 11.09 10.38
SPLIT MSE COOLING COIL Coil:Cooling:DX:SingleSpeed 7771.6 3.15 10.75 11.17 10.49
SPLIT MNE COOLING COIL Coil:Cooling:DX:SingleSpeed 4833.4 3.13 10.68 11.10 10.40
SPLIT MN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 3606.0 3.13 10.69 11.11 10.41
SPLIT MN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 3576.7 3.13 10.70 11.11 10.41
SPLIT MS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 6247.2 3.16 10.79 11.22 10.55
SPLIT MS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 6264.2 3.16 10.79 11.22 10.55
SPLIT TSW COOLING COIL Coil:Cooling:DX:SingleSpeed 5506.4 3.13 10.69 11.11 10.41
SPLIT TNW COOLING COIL Coil:Cooling:DX:SingleSpeed 4343.6 3.13 10.67 11.09 10.38
SPLIT TSE COOLING COIL Coil:Cooling:DX:SingleSpeed 5185.7 3.14 10.71 11.13 10.44
SPLIT TNE COOLING COIL Coil:Cooling:DX:SingleSpeed 3615.5 3.16 10.77 11.20 10.52
SPLIT TN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 2853.7 3.17 10.80 11.23 10.57
SPLIT TN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 2851.5 3.17 10.80 11.23 10.57
SPLIT TS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 4390.2 3.15 10.73 11.15 10.46
SPLIT TS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 4401.6 3.14 10.73 11.15 10.46
ANSI/AHRI ratings include supply fan

DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
SPLIT GSW HEATING COIL Coil:Heating:Gas   2140.09 0.80
SPLIT GNW HEATING COIL Coil:Heating:Gas   2117.83 0.80
SPLIT OFFICE HEATING COIL Coil:Heating:Gas   3966.80 0.80
SPLIT GNE HEATING COIL Coil:Heating:Gas   2117.83 0.80
SPLIT GN1 HEATING COIL Coil:Heating:Gas   1733.86 0.80
SPLIT GN2 HEATING COIL Coil:Heating:Gas   1733.86 0.80
SPLIT GS1 HEATING COIL Coil:Heating:Gas   1733.86 0.80
SPLIT GS2 HEATING COIL Coil:Heating:Gas   1733.86 0.80
SPLIT MSW HEATING COIL Coil:Heating:Gas   4028.96 0.80
SPLIT MNW HEATING COIL Coil:Heating:Gas   4048.78 0.80
SPLIT MSE HEATING COIL Coil:Heating:Gas   4028.96 0.80
SPLIT MNE HEATING COIL Coil:Heating:Gas   4048.78 0.80
SPLIT MN1 HEATING COIL Coil:Heating:Gas   3467.71 0.80
SPLIT MN2 HEATING COIL Coil:Heating:Gas   3467.71 0.80
SPLIT MS1 HEATING COIL Coil:Heating:Gas   3467.71 0.80
SPLIT MS2 HEATING COIL Coil:Heating:Gas   3467.71 0.80
SPLIT TSW HEATING COIL Coil:Heating:Gas   3146.11 0.80
SPLIT TNW HEATING COIL Coil:Heating:Gas   3158.16 0.80
SPLIT TSE HEATING COIL Coil:Heating:Gas   3146.11 0.80
SPLIT TNE HEATING COIL Coil:Heating:Gas   3158.16 0.80
SPLIT TN1 HEATING COIL Coil:Heating:Gas   2472.26 0.80
SPLIT TN2 HEATING COIL Coil:Heating:Gas   2472.26 0.80
SPLIT TS1 HEATING COIL Coil:Heating:Gas   2458.18 0.80
SPLIT TS2 HEATING COIL Coil:Heating:Gas   2458.18 0.80


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
SPLIT GSW SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 216.98 1160.84 1.00 General
SPLIT GNW SUPPLY FAN Fan:OnOff 0.54 622.50 0.15 172.99 1160.84 1.00 General
SPLIT OFFICE SUPPLY FAN Fan:OnOff 0.54 622.50 0.46 538.88 1160.84 1.00 General
SPLIT GNE SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 116.65 1160.84 1.00 General
SPLIT GN1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.08 88.81 1160.84 1.00 General
SPLIT GN2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.08 87.49 1160.84 1.00 General
SPLIT GS1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.13 153.42 1160.84 1.00 General
SPLIT GS2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 157.09 1160.84 1.00 General
SPLIT MSW SUPPLY FAN Fan:OnOff 0.54 622.50 0.51 593.06 1160.84 1.00 General
SPLIT MNW SUPPLY FAN Fan:OnOff 0.54 622.50 0.41 475.16 1160.84 1.00 General
SPLIT MSE SUPPLY FAN Fan:OnOff 0.54 622.50 0.47 551.14 1160.84 1.00 General
SPLIT MNE SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 353.39 1160.84 1.00 General
SPLIT MN1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 262.50 1160.84 1.00 General
SPLIT MN2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 260.19 1160.84 1.00 General
SPLIT MS1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.37 433.53 1160.84 1.00 General
SPLIT MS2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.37 434.83 1160.84 1.00 General
SPLIT TSW SUPPLY FAN Fan:OnOff 0.54 622.50 0.35 401.44 1160.84 1.00 General
SPLIT TNW SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 319.74 1160.84 1.00 General
SPLIT TSE SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 373.95 1160.84 1.00 General
SPLIT TNE SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 253.38 1160.84 1.00 General
SPLIT TN1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 196.72 1160.84 1.00 General
SPLIT TN2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.17 196.55 1160.84 1.00 General
SPLIT TS1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.27 313.73 1160.84 1.00 General
SPLIT TS2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.27 314.60 1160.84 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
None              


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
G SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M SE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T SE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 18:48:09

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1975.19 2370.23 0.156 0.187 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 15:45:00 32.61 0.00850
G NW APARTMENT 1574.78 1889.74 0.124 0.149 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:00:00 29.60 0.00850
OFFICE 4803.48 5764.18 0.387 0.464 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 09:00:00 24.83 0.00850
G NE APARTMENT 1061.89 1274.27 0.084 0.100 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 10:45:00 29.18 0.00850
G N1 APARTMENT 808.50 970.20 0.064 0.077 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:45:00 27.87 0.00850
G N2 APARTMENT 796.44 955.73 0.063 0.075 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:45:00 27.87 0.00850
G S1 APARTMENT 1396.63 1675.95 0.110 0.132 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.11 0.00850
G S2 APARTMENT 1430.06 1716.07 0.113 0.135 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.11 0.00850
M SW APARTMENT 5398.75 6478.50 0.426 0.511 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 16:15:00 32.07 0.00850
M NW APARTMENT 4325.51 5190.61 0.341 0.409 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:00:00 29.60 0.00850
M SE APARTMENT 5017.11 6020.53 0.396 0.475 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 13:45:00 33.11 0.00850
M NE APARTMENT 3217.01 3860.41 0.254 0.304 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 10:45:00 29.18 0.00850
M N1 APARTMENT 2389.62 2867.54 0.188 0.226 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:45:00 27.87 0.00850
M N2 APARTMENT 2368.60 2842.32 0.187 0.224 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 18:45:00 27.87 0.00850
M S1 APARTMENT 3946.51 4735.81 0.311 0.373 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.30 0.00850
M S2 APARTMENT 3958.39 4750.07 0.312 0.375 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.30 0.00850
T SW APARTMENT 3654.33 4385.19 0.288 0.346 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 15:30:00 32.84 0.00850
T NW APARTMENT 2910.61 3492.73 0.230 0.275 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 17:00:00 31.14 0.00850
T SE APARTMENT 3404.11 4084.93 0.268 0.322 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.30 0.00850
T NE APARTMENT 2306.58 2767.89 0.182 0.218 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:30:00 33.30 0.00850
T N1 APARTMENT 1790.77 2148.93 0.141 0.169 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 15:15:00 33.07 0.00850
T N2 APARTMENT 1789.25 2147.10 0.141 0.169 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 15:15:00 33.07 0.00850
T S1 APARTMENT 2855.96 3427.15 0.225 0.270 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:15:00 33.30 0.00850
T S2 APARTMENT 2863.84 3436.61 0.226 0.271 SALEM MCNARY FIELD ANN CLG .4% CONDNS DB=>MWB 8/21 14:00:00 33.30 0.00850


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1063.62 1276.34 0.031 0.037 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.60 0.00237
G NW APARTMENT 1071.03 1285.23 0.031 0.037 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.60 0.00237
OFFICE 2352.50 2823.00 0.066 0.079 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.60 0.00237
G NE APARTMENT 1071.03 1285.23 0.031 0.037 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.60 0.00237
G N1 APARTMENT 632.08 758.50 0.018 0.026 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.60 0.00237
G N2 APARTMENT 632.08 758.50 0.018 0.026 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.60 0.00237
G S1 APARTMENT 626.15 751.38 0.018 0.026 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.60 0.00237
G S2 APARTMENT 704.83 845.80 0.020 0.026 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.60 0.00237
M SW APARTMENT 1967.32 2360.78 0.057 0.068 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.60 0.00237
M NW APARTMENT 1984.08 2380.89 0.057 0.069 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.60 0.00237
M SE APARTMENT 1967.32 2360.78 0.057 0.068 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.60 0.00237
M NE APARTMENT 1984.08 2380.89 0.057 0.069 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.60 0.00237
M N1 APARTMENT 889.03 1066.83 0.026 0.052 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.60 0.00237
M N2 APARTMENT 889.03 1066.83 0.026 0.052 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.60 0.00237
M S1 APARTMENT 873.70 1048.44 0.025 0.052 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.60 0.00237
M S2 APARTMENT 873.70 1048.44 0.025 0.052 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.60 0.00237
T SW APARTMENT 1940.64 2328.77 0.056 0.067 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.60 0.00237
T NW APARTMENT 1950.84 2341.00 0.057 0.068 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.60 0.00237
T SE APARTMENT 1940.64 2328.77 0.056 0.067 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.60 0.00237
T NE APARTMENT 1950.84 2341.00 0.057 0.068 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.60 0.00237
T N1 APARTMENT 1370.77 1644.93 0.040 0.048 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.60 0.00237
T N2 APARTMENT 1370.77 1644.93 0.040 0.048 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.60 0.00237
T S1 APARTMENT 1358.86 1630.64 0.039 0.047 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.60 0.00237
T S2 APARTMENT 1358.86 1630.64 0.039 0.047 SALEM MCNARY FIELD ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.60 0.00237


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
SPLIT GSW 0.19 0.19 0.04 0.04
SPLIT GNW 0.15 0.15 0.04 0.04
SPLIT OFFICE 0.46 0.46 0.08 0.08
SPLIT GNE 0.10 0.10 0.04 0.04
SPLIT GN1 0.08 0.08 0.03 0.03
SPLIT GN2 0.08 0.08 0.03 0.03
SPLIT GS1 0.13 0.13 0.03 0.03
SPLIT GS2 0.14 0.14 0.03 0.03
SPLIT MSW 0.51 0.51 0.07 0.07
SPLIT MNW 0.41 0.41 0.07 0.07
SPLIT MSE 0.47 0.47 0.07 0.07
SPLIT MNE 0.30 0.30 0.07 0.07
SPLIT MN1 0.23 0.23 0.05 0.05
SPLIT MN2 0.22 0.22 0.05 0.05
SPLIT MS1 0.37 0.37 0.05 0.05
SPLIT MS2 0.37 0.37 0.05 0.05
SPLIT TSW 0.35 0.35 0.07 0.07
SPLIT TNW 0.28 0.28 0.07 0.07
SPLIT TSE 0.32 0.32 0.07 0.07
SPLIT TNE 0.22 0.22 0.07 0.07
SPLIT TN1 0.17 0.17 0.05 0.05
SPLIT TN2 0.17 0.17 0.05 0.05
SPLIT TS1 0.27 0.27 0.05 0.05
SPLIT TS2 0.27 0.27 0.05 0.05



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2015-09-09 18:48:09

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 1583.00 6173.00 167.50
G NW APARTMENT 1229.00 6538.50 254.25
OFFICE 359.25 1512.50 24.00
G NE APARTMENT 1203.75 6657.25 245.00
G N1 APARTMENT 694.50 6741.75 147.75
G N2 APARTMENT 688.50 6758.25 147.50
G S1 APARTMENT 1212.25 6197.25 88.50
G S2 APARTMENT 1310.75 6131.75 96.75
M SW APARTMENT 2899.75 4041.50 27.25
M NW APARTMENT 2591.75 4833.00 106.00
M SE APARTMENT 2856.50 4120.50 24.50
M NE APARTMENT 2533.25 4965.25 106.25
M N1 APARTMENT 2327.00 4759.00 38.25
M N2 APARTMENT 2322.75 4778.25 38.75
M S1 APARTMENT 2781.25 3713.25 0.00
M S2 APARTMENT 2781.75 3722.00 0.00
T SW APARTMENT 2611.75 5200.25 375.25
T NW APARTMENT 2445.50 5837.50 552.25
T SE APARTMENT 2612.25 5262.25 377.00
T NE APARTMENT 2408.25 5919.50 547.50
T N1 APARTMENT 2078.00 5864.75 322.50
T N2 APARTMENT 2077.50 5872.00 322.50
T S1 APARTMENT 2379.00 5035.75 201.00
T S2 APARTMENT 2378.50 5041.50 201.00
T CORRIDOR 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
Facility 3773.50 6875.00 580.75
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 3.25 0.00 3.25 0.00
G NW APARTMENT 9.25 0.00 9.25 0.00
OFFICE 3.50 2.00 0.00 0.00
G NE APARTMENT 10.75 13.25 10.75 13.25
G N1 APARTMENT 11.00 15.00 11.00 15.00
G N2 APARTMENT 9.50 15.25 9.50 15.25
G S1 APARTMENT 8.75 0.00 8.75 0.00
G S2 APARTMENT 9.00 0.00 9.00 0.00
M SW APARTMENT 2.75 0.00 2.75 0.00
M NW APARTMENT 7.25 0.00 7.25 0.00
M SE APARTMENT 3.00 0.00 3.00 0.00
M NE APARTMENT 10.00 6.25 10.00 6.25
M N1 APARTMENT 2.00 9.50 2.00 9.50
M N2 APARTMENT 2.00 11.50 2.00 11.50
M S1 APARTMENT 1.00 0.00 1.00 0.00
M S2 APARTMENT 1.00 0.00 1.00 0.00
T SW APARTMENT 2.75 0.00 2.75 0.00
T NW APARTMENT 5.00 0.00 5.00 0.00
T SE APARTMENT 3.25 0.00 3.25 0.00
T NE APARTMENT 5.25 0.00 5.25 0.00
T N1 APARTMENT 3.25 0.25 3.25 0.25
T N2 APARTMENT 4.75 0.00 4.75 0.00
T S1 APARTMENT 1.25 0.00 1.25 0.00
T S2 APARTMENT 1.75 0.00 1.75 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
Facility 83.25 19.50 79.75 17.50
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2015-09-09 18:48:09

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.97 0.365 0.153 0.000 0.068
G NW APARTMENT 1.71 2.50 268.97 0.352 0.153 0.000 0.067
OFFICE 0.94 1.00 268.97 0.519 0.176 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.352 0.153 0.000 0.067
G N1 APARTMENT 1.71 2.50 268.97 0.352 0.092 0.000 0.066
G N2 APARTMENT 1.71 2.50 268.97 0.352 0.092 0.000 0.066
G S1 APARTMENT 1.71 2.50 268.97 0.352 0.092 0.000 0.068
G S2 APARTMENT 1.71 2.50 268.97 0.352 0.092 0.000 0.068
M SW APARTMENT 1.71 2.50 268.97 0.353 0.221 0.000 0.081
M NW APARTMENT 1.71 2.50 268.97 0.353 0.220 0.000 0.082
M SE APARTMENT 1.71 2.50 268.97 0.353 0.221 0.000 0.081
M NE APARTMENT 1.71 2.50 268.97 0.353 0.220 0.000 0.081
M N1 APARTMENT 1.71 2.50 268.97 0.353 0.133 0.000 0.081
M N2 APARTMENT 1.71 2.50 268.97 0.353 0.133 0.000 0.081
M S1 APARTMENT 1.71 2.50 268.97 0.353 0.133 0.000 0.081
M S2 APARTMENT 1.71 2.50 268.97 0.353 0.133 0.000 0.081
T SW APARTMENT 1.71 2.50 268.97 0.353 0.292 0.000 0.092
T NW APARTMENT 1.71 2.50 268.97 0.352 0.291 0.000 0.093
T SE APARTMENT 1.71 2.50 268.97 0.353 0.291 0.000 0.092
T NE APARTMENT 1.71 2.50 268.97 0.352 0.291 0.000 0.093
T N1 APARTMENT 1.71 2.50 268.97 0.352 0.176 0.000 0.093
T N2 APARTMENT 1.71 2.50 268.97 0.352 0.176 0.000 0.093
T S1 APARTMENT 1.71 2.50 268.97 0.353 0.176 0.000 0.092
T S2 APARTMENT 1.71 2.50 268.97 0.353 0.176 0.000 0.092
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.97 0.353 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
OFFICE 0.94 1.00 268.97 0.500 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.97 1.363 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.97 1.363 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.97 1.363 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.97 1.363 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.97 1.363 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 1.363 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.97 1.363 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 1.363 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.341 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2015-09-09 18:48:09

Surfaces by Class

Total Outdoors
Wall 126 42
Floor 27 9
Roof 27 9
Internal Mass 24 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 39 39
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 24
Conditioned Zones 24
Unconditioned Zones 3
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 1385
Defaulted Fields 439
Fields with Defaults 3704
Autosized Fields 336
Autosizable Fields 454
Autocalculated Fields 247
Autocalculatable Fields 424



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2015-09-09 18:48:09

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 1384.93 20378.84 01-JAN-03:15 84248.10 18-JUL-16:15
Electricity:Building 636.11 10559.61 01-JAN-03:15 31610.87 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity 118.46 2466.75 01-JAN-00:15 5482.59 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 96.36 2205.67 01-JAN-00:15 4426.44 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:OFFICE 35.93 610.39 01-JAN-00:15 2669.36 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 26.45 416.15 01-JAN-00:15 2080.74 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M SW APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:T SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G CORRIDOR 144.16 1427.03 01-JAN-00:15 8651.76 01-JAN-07:15
InteriorLights:Electricity:Zone:G CORRIDOR 14.58 462.39 01-JAN-00:15 462.39 01-JAN-00:15
Electricity:Zone:M CORRIDOR 29.16 924.77 01-JAN-00:15 924.77 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 29.16 924.77 01-JAN-00:15 924.77 01-JAN-00:15
Electricity:Zone:T CORRIDOR 14.58 462.39 01-JAN-00:15 462.39 01-JAN-00:15
InteriorLights:Electricity:Zone:T CORRIDOR 14.58 462.39 01-JAN-00:15 462.39 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 22.11 261.08 01-JAN-00:15 1411.40 02-JAN-16:15
InteriorEquipment:Electricity 517.65 8092.87 01-JAN-03:15 26730.99 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 517.65 8092.87 01-JAN-03:15 26730.99 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 9.48 194.25 01-JAN-00:15 588.62 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G CORRIDOR 129.57 964.65 01-JAN-00:15 8189.37 01-JAN-07:15
Electricity:Plant 402.84 0.00 01-JAN-00:15 32482.32 05-FEB-07:45
WaterSystems:Electricity 402.84 0.00 01-JAN-00:15 32482.32 05-FEB-07:45
Water Heater:WaterSystems:Electricity 402.84 0.00 01-JAN-00:15 32482.32 05-FEB-07:45
Fans:Electricity 229.15 7266.23 01-JAN-17:15 7266.23 03-JAN-08:15
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 1384.93 20378.84 01-JAN-03:15 84248.10 18-JUL-16:15
ElectricityPurchased:Plant 1384.93 20378.84 01-JAN-03:15 84248.10 18-JUL-16:15
Cogeneration:ElectricityPurchased 1384.93 20378.84 01-JAN-03:15 84248.10 18-JUL-16:15
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 1384.93 20378.84 01-JAN-03:15 84248.10 18-JUL-16:15
ElectricityNet:Plant 1384.93 20378.84 01-JAN-03:15 84248.10 18-JUL-16:15
Cogeneration:ElectricityNet 1384.93 20378.84 01-JAN-03:15 84248.10 18-JUL-16:15
ExteriorLights:Electricity 40.10 0.00 01-JAN-08:00 2553.00 01-JAN-00:15
General:ExteriorLights:Electricity 40.10 0.00 01-JAN-08:00 2553.00 01-JAN-00:15
Electricity:HVAC 305.87 7266.23 01-JAN-17:15 31871.43 17-JUL-16:00
General:Fans:Electricity 229.15 7266.23 01-JAN-17:15 7266.23 03-JAN-08:15
Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:Electricity 76.72 0.00 01-JAN-00:15 24605.20 17-JUL-16:00


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 230.87 0.00 21-FEB-13:45 78565.15 20-DEC-05:00
Gas:HVAC 230.87 0.00 21-FEB-13:45 78565.15 20-DEC-05:00
Heating:Gas 230.87 0.00 21-FEB-13:45 78565.15 20-DEC-05:00


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
None          


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water:Plant 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
WaterSystems:Water 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
MainsWater:Facility 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
MainsWater:Plant 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
WaterSystems:MainsWater 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
PlantLoopHeatingDemand:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 931.60 1534.97 10-NOV-12:15 157195.94 19-JUL-16:00
EnergyTransfer:Building 439.37 1534.97 10-NOV-12:15 66474.15 19-JUL-16:00
EnergyTransfer:Zone:G SW APARTMENT 10.26 0.00 30-JUN-15:30 2121.88 09-SEP-15:15
Heating:EnergyTransfer 99.03 0.00 15-JAN-18:45 49879.44 15-FEB-02:00
Heating:EnergyTransfer:Zone:G SW APARTMENT 3.79 0.00 01-JAN-09:45 1676.68 15-FEB-02:00
Cooling:EnergyTransfer 340.34 0.00 03-JAN-07:30 66474.15 19-JUL-16:00
Cooling:EnergyTransfer:Zone:G SW APARTMENT 6.47 0.00 01-JAN-00:15 2121.88 09-SEP-15:15
EnergyTransfer:Zone:G NW APARTMENT 9.46 0.01 04-OCT-08:45 1903.86 15-JUL-18:00
Heating:EnergyTransfer:Zone:G NW APARTMENT 4.91 0.00 15-JAN-16:15 1642.03 15-FEB-02:00
Cooling:EnergyTransfer:Zone:G NW APARTMENT 4.55 0.00 01-JAN-00:15 1903.86 15-JUL-18:00
EnergyTransfer:Zone:OFFICE 20.28 0.00 17-AUG-04:45 4500.45 10-SEP-13:00
Heating:EnergyTransfer:Zone:OFFICE 1.57 0.00 01-JAN-00:15 2495.56 24-DEC-07:15
Cooling:EnergyTransfer:Zone:OFFICE 18.70 0.00 02-JAN-07:45 4500.45 10-SEP-13:00
EnergyTransfer:Zone:G NE APARTMENT 9.53 0.04 06-OCT-15:45 1587.70 15-FEB-02:00
Heating:EnergyTransfer:Zone:G NE APARTMENT 4.91 0.00 15-JAN-16:15 1587.70 15-FEB-02:00
Cooling:EnergyTransfer:Zone:G NE APARTMENT 4.62 0.00 01-JAN-00:15 1303.07 16-JUL-18:45
EnergyTransfer:Zone:G N1 APARTMENT 6.55 0.03 15-OCT-04:15 1005.37 15-FEB-02:00
Heating:EnergyTransfer:Zone:G N1 APARTMENT 2.09 0.00 02-JAN-19:30 1005.37 15-FEB-02:00
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 4.46 0.00 01-JAN-00:15 980.35 15-JUL-19:15
EnergyTransfer:Zone:G N2 APARTMENT 6.54 0.01 15-OCT-04:15 1005.56 15-FEB-02:00
Heating:EnergyTransfer:Zone:G N2 APARTMENT 2.09 0.00 02-JAN-19:30 1005.56 15-FEB-02:00
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 4.45 0.00 01-JAN-00:15 965.58 16-JUL-19:30
EnergyTransfer:Zone:G S1 APARTMENT 7.69 0.01 10-NOV-13:15 1455.41 09-SEP-13:45
Heating:EnergyTransfer:Zone:G S1 APARTMENT 1.36 0.00 01-JAN-08:45 980.81 15-FEB-02:15
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 6.33 0.00 01-JAN-00:15 1455.41 09-SEP-13:45
EnergyTransfer:Zone:G S2 APARTMENT 7.96 0.01 28-DEC-17:45 1548.87 09-SEP-13:30
Heating:EnergyTransfer:Zone:G S2 APARTMENT 1.45 0.00 01-JAN-09:00 1029.17 15-FEB-02:15
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 6.51 0.00 01-JAN-00:15 1548.87 09-SEP-13:30
EnergyTransfer:Zone:M SW APARTMENT 33.69 0.14 26-OCT-11:30 5864.35 09-SEP-15:15
Heating:EnergyTransfer:Zone:M SW APARTMENT 3.93 0.00 01-JAN-00:15 3422.37 15-FEB-02:00
Cooling:EnergyTransfer:Zone:M SW APARTMENT 29.76 0.00 01-JAN-02:30 5864.35 09-SEP-15:15
EnergyTransfer:Zone:M NW APARTMENT 27.03 0.00 06-OCT-08:45 5363.03 24-JUN-18:15
Heating:EnergyTransfer:Zone:M NW APARTMENT 5.88 0.00 01-JAN-17:30 3332.97 15-FEB-02:00
Cooling:EnergyTransfer:Zone:M NW APARTMENT 21.15 0.00 01-JAN-00:15 5363.03 24-JUN-18:15
EnergyTransfer:Zone:M SE APARTMENT 33.14 0.01 09-NOV-21:00 5209.49 09-SEP-13:30
Heating:EnergyTransfer:Zone:M SE APARTMENT 3.95 0.00 01-JAN-00:15 3385.83 15-FEB-02:00
Cooling:EnergyTransfer:Zone:M SE APARTMENT 29.19 0.00 01-JAN-02:30 5209.49 09-SEP-13:30
EnergyTransfer:Zone:M NE APARTMENT 26.95 0.06 07-APR-06:45 3940.14 24-JUN-18:45
Heating:EnergyTransfer:Zone:M NE APARTMENT 5.92 0.00 01-JAN-09:30 3203.97 15-FEB-02:00
Cooling:EnergyTransfer:Zone:M NE APARTMENT 21.03 0.00 01-JAN-00:15 3940.14 24-JUN-18:45
EnergyTransfer:Zone:M N1 APARTMENT 23.02 0.23 19-NOV-22:00 2985.80 24-JUN-19:30
Heating:EnergyTransfer:Zone:M N1 APARTMENT 1.28 0.00 01-JAN-06:30 2065.80 15-FEB-02:00
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 21.74 0.00 01-JAN-00:15 2985.80 24-JUN-19:30
EnergyTransfer:Zone:M N2 APARTMENT 22.96 0.23 09-DEC-04:45 2959.47 24-JUN-19:30
Heating:EnergyTransfer:Zone:M N2 APARTMENT 1.28 0.00 01-JAN-06:30 2066.24 15-FEB-02:00
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 21.67 0.00 01-JAN-00:15 2959.47 24-JUN-19:30
EnergyTransfer:Zone:M S1 APARTMENT 31.57 0.06 13-JAN-01:30 4242.08 09-SEP-14:15
Heating:EnergyTransfer:Zone:M S1 APARTMENT 0.67 0.00 01-JAN-00:15 1939.88 15-FEB-02:00
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 30.90 0.00 03-JAN-05:45 4242.08 09-SEP-14:15
EnergyTransfer:Zone:M S2 APARTMENT 31.52 0.17 12-DEC-13:45 4245.36 09-SEP-14:15
Heating:EnergyTransfer:Zone:M S2 APARTMENT 0.67 0.00 01-JAN-00:15 1940.22 15-FEB-02:00
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 30.84 0.00 03-JAN-05:45 4245.36 09-SEP-14:15
EnergyTransfer:Zone:T SW APARTMENT 20.11 0.02 02-MAY-23:00 3964.04 17-JUL-16:15
Heating:EnergyTransfer:Zone:T SW APARTMENT 8.08 0.00 01-JAN-10:00 2960.65 15-FEB-02:00
Cooling:EnergyTransfer:Zone:T SW APARTMENT 12.03 0.00 01-JAN-00:15 3964.04 17-JUL-16:15
EnergyTransfer:Zone:T NW APARTMENT 18.15 0.00 28-JUN-02:15 3575.88 24-JUN-18:00
Heating:EnergyTransfer:Zone:T NW APARTMENT 9.63 0.00 15-JAN-17:45 2892.92 15-FEB-02:00
Cooling:EnergyTransfer:Zone:T NW APARTMENT 8.52 0.00 01-JAN-00:15 3575.88 24-JUN-18:00
EnergyTransfer:Zone:T SE APARTMENT 19.62 0.01 27-JUL-04:45 3448.38 09-SEP-13:45
Heating:EnergyTransfer:Zone:T SE APARTMENT 8.00 0.00 01-JAN-09:30 2935.59 15-FEB-02:00
Cooling:EnergyTransfer:Zone:T SE APARTMENT 11.61 0.00 01-JAN-00:15 3448.38 09-SEP-13:45
EnergyTransfer:Zone:T NE APARTMENT 17.94 0.01 15-OCT-15:00 2867.29 17-JUL-16:30
Heating:EnergyTransfer:Zone:T NE APARTMENT 9.59 0.00 15-JAN-17:15 2820.89 15-FEB-02:00
Cooling:EnergyTransfer:Zone:T NE APARTMENT 8.35 0.00 01-JAN-00:15 2867.29 17-JUL-16:30
EnergyTransfer:Zone:T N1 APARTMENT 12.80 0.03 08-AUG-09:45 2229.47 17-JUL-17:45
Heating:EnergyTransfer:Zone:T N1 APARTMENT 5.13 0.00 14-JAN-18:45 2005.20 15-FEB-02:00
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 7.66 0.00 01-JAN-00:15 2229.47 17-JUL-17:45
EnergyTransfer:Zone:T N2 APARTMENT 12.79 0.01 19-OCT-12:30 2221.14 17-JUL-17:30
Heating:EnergyTransfer:Zone:T N2 APARTMENT 5.15 0.00 14-JAN-18:45 2005.61 15-FEB-02:00
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 7.64 0.00 01-JAN-00:15 2221.14 17-JUL-17:30
EnergyTransfer:Zone:T S1 APARTMENT 14.91 0.00 12-NOV-15:30 2909.78 09-SEP-14:15
Heating:EnergyTransfer:Zone:T S1 APARTMENT 3.83 0.00 01-JAN-09:30 1988.02 15-FEB-02:00
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 11.09 0.00 01-JAN-00:15 2909.78 09-SEP-14:15
EnergyTransfer:Zone:T S2 APARTMENT 14.91 0.02 27-OCT-10:30 2910.96 09-SEP-13:45
Heating:EnergyTransfer:Zone:T S2 APARTMENT 3.83 0.00 01-JAN-09:30 1988.24 15-FEB-02:00
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 11.07 0.00 01-JAN-00:15 2910.96 09-SEP-13:45
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:HVAC 492.23 0.00 13-APR-19:45 90851.59 19-JUL-15:45
HeatingCoils:EnergyTransfer 184.70 0.00 21-FEB-13:45 62852.12 20-DEC-05:00
CoolingCoils:EnergyTransfer 307.54 0.00 01-JAN-00:15 90851.59 19-JUL-15:45



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2015-09-09 18:48:09

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 3.789 -6.473 0.000 0.000 3.870 1.087 12.213 12.588 0.000 0.138 0.000 0.000 -6.864 0.000 -5.527 -14.819
G NW APARTMENT 4.914 -4.551 0.000 0.000 3.897 1.087 12.213 6.884 0.000 0.139 0.000 0.000 -6.887 0.000 -5.398 -12.298
OFFICE 1.575 -18.702 0.000 0.000 0.521 26.452 9.482 11.778 0.000 0.075 0.001 0.000 -6.948 0.000 -4.882 -19.350
G NE APARTMENT 4.914 -4.621 0.000 0.000 3.912 1.087 12.213 6.255 0.000 0.139 0.000 0.000 -6.715 0.000 -5.368 -11.815
G N1 APARTMENT 2.091 -4.459 0.000 0.000 3.910 1.087 12.213 2.388 0.000 0.094 0.000 0.000 -4.199 0.000 -3.522 -9.602
G N2 APARTMENT 2.092 -4.450 0.000 0.000 3.911 1.087 12.213 2.388 0.000 0.094 0.000 0.000 -4.197 0.000 -3.521 -9.616
G S1 APARTMENT 1.357 -6.333 0.000 0.000 3.870 1.087 12.213 8.138 0.000 0.091 0.000 0.000 -4.183 0.000 -3.667 -12.574
G S2 APARTMENT 1.448 -6.514 0.000 0.000 3.867 1.087 12.213 8.132 0.000 0.091 0.000 0.000 -4.188 0.000 -3.675 -12.461
M SW APARTMENT 3.934 -29.756 0.000 0.000 3.729 1.087 12.213 12.138 0.000 0.194 12.128 0.000 -7.581 0.000 -8.084 -0.001
M NW APARTMENT 5.878 -21.148 0.000 0.000 3.781 1.087 12.213 6.498 0.000 0.196 6.920 0.000 -7.512 0.000 -7.912 -0.000
M SE APARTMENT 3.953 -29.189 0.000 0.000 3.737 1.087 12.213 11.526 0.000 0.194 11.974 0.000 -7.427 0.000 -8.068 -0.001
M NE APARTMENT 5.922 -21.025 0.000 0.000 3.798 1.087 12.213 5.867 0.000 0.195 7.121 0.000 -7.308 0.000 -7.869 -0.001
M N1 APARTMENT 1.280 -21.738 0.000 0.000 3.773 1.087 12.213 2.145 0.000 0.128 10.959 0.000 -4.648 0.000 -5.199 -0.000
M N2 APARTMENT 1.283 -21.675 0.000 0.000 3.775 1.087 12.213 2.146 0.000 0.128 10.883 0.000 -4.644 0.000 -5.196 -0.000
M S1 APARTMENT 0.672 -30.902 0.000 0.000 3.698 1.087 12.213 7.849 0.000 0.127 15.295 0.000 -4.672 0.000 -5.366 0.000
M S2 APARTMENT 0.672 -30.844 0.000 0.000 3.698 1.087 12.213 7.849 0.000 0.127 15.234 0.000 -4.670 0.000 -5.366 0.000
T SW APARTMENT 8.081 -12.026 0.000 0.000 3.810 1.087 12.213 12.085 0.000 0.255 0.000 0.000 -7.109 0.000 -10.228 -8.167
T NW APARTMENT 9.633 -8.520 0.000 0.000 3.850 1.087 12.213 6.478 0.000 0.257 0.000 0.000 -7.070 0.000 -10.045 -7.883
T SE APARTMENT 8.004 -11.611 0.000 0.000 3.818 1.087 12.213 11.495 0.000 0.255 0.000 0.000 -6.979 0.000 -10.220 -8.062
T NE APARTMENT 9.590 -8.347 0.000 0.000 3.868 1.087 12.213 5.873 0.000 0.257 0.000 0.000 -6.899 0.000 -10.009 -7.633
T N1 APARTMENT 5.135 -7.660 0.000 0.000 3.852 1.087 12.213 2.171 0.000 0.170 0.000 0.000 -4.334 0.000 -6.488 -6.145
T N2 APARTMENT 5.149 -7.637 0.000 0.000 3.853 1.087 12.213 2.170 0.000 0.170 0.000 0.000 -4.330 0.000 -6.488 -6.186
T S1 APARTMENT 3.827 -11.086 0.000 0.000 3.793 1.087 12.213 7.837 0.000 0.167 0.000 0.000 -4.375 0.000 -6.671 -6.792
T S2 APARTMENT 3.835 -11.073 0.000 0.000 3.793 1.087 12.213 7.836 0.000 0.167 0.000 0.000 -4.372 0.000 -6.672 -6.814
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 14.582 0.000 0.085 0.000 0.014 0.000 0.000 -0.854 0.000 -1.668 -12.159
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 14.582 6.479 0.321 0.000 0.430 7.350 0.000 -2.196 0.000 -26.966 -0.000
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 14.582 0.000 0.084 0.000 0.013 0.000 0.000 -0.946 0.000 -1.385 -12.348
Total Facility 99.027 -340.341 0.000 0.000 88.384 95.189 296.854 171.006 0.000 4.308 97.864 0.000 -142.107 0.000 -185.460 -184.727


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 09-SEP-15:15 0.00 -2121.91 0.00 0.00 48.90 45.40 470.90 2657.62 0.00 241.39 0.00 0.00 0.00 0.00 0.00 -1342.30
G NW APARTMENT 15-JUL-18:00 0.00 -1903.96 0.00 0.00 141.37 87.56 588.62 1977.22 0.00 208.66 0.00 0.00 0.00 0.00 0.00 -1099.47
OFFICE 17-SEP-06:01 0.00 -7390.76 0.00 0.00 0.00 416.15 294.31 298.71 0.00 0.00 6381.59 0.00 0.00 0.00 0.00 0.00
G NE APARTMENT 16-JUL-18:45 0.00 -1303.34 0.00 0.00 140.77 103.77 547.42 638.84 0.00 107.68 0.00 0.00 0.00 0.00 0.00 -235.13
G N1 APARTMENT 15-JUL-19:15 0.00 -980.48 0.00 0.00 140.16 103.77 523.87 510.87 0.00 80.52 0.00 0.00 0.00 0.00 0.00 -378.72
G N2 APARTMENT 16-JUL-19:30 0.00 -965.68 0.00 0.00 140.79 103.77 523.87 334.79 0.00 45.12 0.00 0.00 0.00 0.00 0.00 -182.67
G S1 APARTMENT 09-SEP-13:45 0.00 -1455.49 0.00 0.00 40.75 12.97 382.60 1921.21 0.00 134.17 0.00 0.00 0.00 0.00 0.00 -1036.21
G S2 APARTMENT 09-SEP-13:30 0.00 -1548.95 0.00 0.00 40.75 12.97 382.60 2002.79 0.00 131.70 0.00 0.00 0.00 0.00 0.00 -1021.87
M SW APARTMENT 09-SEP-15:15 0.00 -5864.41 0.00 0.00 48.90 45.40 470.90 2639.16 0.00 346.15 2313.90 0.00 0.00 0.00 0.00 0.00
M NW APARTMENT 24-JUN-18:15 0.00 -5362.76 0.00 0.00 141.56 103.77 547.42 1999.80 0.00 325.00 2245.22 0.00 0.00 0.00 0.00 0.00
M SE APARTMENT 09-SEP-13:30 0.00 -5209.73 0.00 0.00 40.75 12.97 382.60 2279.62 0.00 313.06 2180.73 0.00 0.00 0.00 0.00 0.00
M NE APARTMENT 24-JUN-18:45 0.00 -3940.01 0.00 0.00 141.29 103.77 547.42 766.32 0.00 250.85 2130.37 0.00 0.00 0.00 0.00 0.00
M N1 APARTMENT 24-JUN-19:30 0.00 -2985.97 0.00 0.00 140.90 103.77 523.87 514.58 0.00 97.42 1605.42 0.00 0.00 0.00 0.00 0.00
M N2 APARTMENT 24-JUN-19:30 0.00 -2959.64 0.00 0.00 140.86 103.77 523.87 514.67 0.00 97.34 1579.13 0.00 0.00 0.00 0.00 0.00
M S1 APARTMENT 09-SEP-14:15 0.00 -4242.27 0.00 0.00 40.75 22.70 400.26 1720.95 0.00 198.24 1859.37 0.00 0.00 0.00 0.00 0.00
M S2 APARTMENT 09-SEP-14:15 0.00 -4245.55 0.00 0.00 40.75 22.70 400.26 1720.92 0.00 198.24 1862.68 0.00 0.00 0.00 0.00 0.00
T SW APARTMENT 17-JUL-16:03 0.00 -3965.20 0.00 0.00 84.76 64.86 588.62 2168.84 0.00 475.71 582.41 0.00 0.00 0.00 0.00 0.00
T NW APARTMENT 15-JUL-17:03 0.00 -3595.39 0.00 0.00 141.73 87.56 588.62 2024.54 0.00 463.98 288.96 0.00 0.00 0.00 0.00 0.00
T SE APARTMENT 09-SEP-13:45 0.00 -3448.53 0.00 0.00 40.75 12.97 382.60 2161.30 0.00 419.92 431.00 0.00 0.00 0.00 0.00 0.00
T NE APARTMENT 17-JUL-16:20 0.00 -2868.18 0.00 0.00 84.05 64.86 588.62 706.79 0.00 446.04 977.82 0.00 0.00 0.00 0.00 0.00
T N1 APARTMENT 16-JUL-17:19 0.00 -2255.73 0.00 0.00 141.80 87.56 588.62 457.55 0.00 134.13 846.07 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 16-JUL-17:03 0.00 -2230.88 0.00 0.00 141.65 87.56 588.62 416.06 0.00 134.48 862.52 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 09-SEP-14:15 0.00 -2909.89 0.00 0.00 40.75 22.70 400.26 1700.45 0.00 261.04 484.69 0.00 0.00 0.00 0.00 0.00
T S2 APARTMENT 09-SEP-13:45 0.00 -2911.09 0.00 0.00 40.75 12.97 382.60 1888.95 0.00 253.29 332.52 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 19-JUL-16:00 0.00 -66478.73 0.00 0.00 1187.56 4512.09 11708.34 23866.13 0.00 10034.55 15170.07 0.00 0.00 0.00 0.00 0.00


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 15-FEB-02:00 1676.72 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -571.04 0.00 -1224.25 -318.92
G NW APARTMENT 15-FEB-02:00 1642.07 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -555.01 0.00 -1221.48 -303.08
OFFICE 09-FEB-07:01 3706.94 0.00 0.00 0.00 0.00 416.15 294.31 0.00 0.00 0.00 0.00 0.00 -337.42 0.00 -412.36 -3667.62
G NE APARTMENT 29-OCT-16:01 1795.72 0.00 0.00 0.00 99.87 64.86 588.62 0.00 0.00 0.00 0.00 0.00 -281.09 0.00 -71.91 -2196.07
G N1 APARTMENT 10-MAR-17:01 1458.01 0.00 0.00 0.00 99.73 64.86 588.62 0.00 0.00 0.00 0.00 0.00 -119.69 0.00 -124.81 -1966.73
G N2 APARTMENT 01-MAR-07:01 1415.48 0.00 0.00 0.00 163.49 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -152.44 0.00 -135.02 -1716.28
G S1 APARTMENT 15-NOV-07:01 1434.43 0.00 0.00 0.00 163.26 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -134.77 0.00 -152.04 -1735.64
G S2 APARTMENT 15-NOV-07:01 1437.28 0.00 0.00 0.00 163.22 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -134.83 0.00 -152.09 -1738.33
M SW APARTMENT 15-FEB-02:00 3422.47 0.00 0.00 0.00 190.44 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -593.01 0.00 -1739.90 -1527.82
M NW APARTMENT 15-FEB-02:00 3333.07 0.00 0.00 0.00 191.91 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -571.28 0.00 -1722.47 -1479.05
M SE APARTMENT 15-FEB-02:00 3385.93 0.00 0.00 0.00 190.61 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -592.70 0.00 -1736.47 -1495.20
M NE APARTMENT 25-NOV-07:01 3465.01 0.00 0.00 0.00 162.84 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -371.61 0.00 -199.85 -3481.15
M N1 APARTMENT 04-MAR-07:01 2463.36 0.00 0.00 0.00 161.37 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -271.86 0.00 -256.72 -2520.91
M N2 APARTMENT 19-DEC-07:03 2080.60 0.00 0.00 0.00 161.22 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -409.99 0.00 -105.57 -2151.03
M S1 APARTMENT 15-FEB-02:00 1939.93 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -363.35 0.00 -1063.44 -950.63
M S2 APARTMENT 15-FEB-02:00 1940.27 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -363.34 0.00 -1063.44 -950.97
T SW APARTMENT 15-FEB-02:00 2960.74 0.00 0.00 0.00 190.34 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -575.19 0.00 -2308.99 -514.72
T NW APARTMENT 15-FEB-02:00 2893.01 0.00 0.00 0.00 190.90 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -556.17 0.00 -2297.17 -478.39
T SE APARTMENT 15-FEB-02:00 2935.68 0.00 0.00 0.00 190.51 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -574.88 0.00 -2304.94 -494.19
T NE APARTMENT 15-FEB-02:00 2820.98 0.00 0.00 0.00 191.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -554.91 0.00 -2284.88 -420.67
T N1 APARTMENT 15-FEB-02:00 2005.25 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -332.28 0.00 -1409.29 -701.17
T N2 APARTMENT 15-FEB-02:00 2005.66 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -332.28 0.00 -1409.29 -701.58
T S1 APARTMENT 15-FEB-02:00 1988.08 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -351.58 0.00 -1409.29 -664.69
T S2 APARTMENT 15-FEB-02:00 1988.29 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -351.58 0.00 -1409.29 -664.91
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 15-FEB-02:00 49699.60 0.00 0.00 0.00 4374.74 1952.47 5793.19 0.00 0.00 0.00 0.00 0.00 -11188.91 0.00 -34507.66 -16123.44



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2015-09-09 18:48:09

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2015-09-09 18:48:09

Sec1.1A-General Information

Data
Weather File Salem Mcnary Field OR USA TMY3 WMO#=726940
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 3134.61
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.32
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
T CORRIDOR 77.66 0.00 77.66 0.00
G CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
Totals 3134.61 2823.98 310.64  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 79.75
Number of hours cooling loads not met 17.50
Number of hours not met 97.25


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 118.46 4276.26 0.00 0.00 0.00 0.00
Exterior Lighting 40.10 0.00 0.00 0.00 0.00 0.00
Space Heating 0.00 0.00 230.87 78565.15 0.00 0.00
Space Cooling 76.72 23107.30 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Fans-Interior 229.15 7266.23 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 402.84 22867.33 0.00 0.00 0.00 0.00
Receptacle Equipment 517.65 26730.99 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 1384.93   230.87   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 517.65 1384.93
Natural Gas 0.00 230.87
Additional 0.00 0.00
Total 517.65 1615.80


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 37.79
Space Heating 0.00
Space Cooling 24.48
Fans-Interior 73.10
Service Water Heating 128.51
Receptacle Equipment 165.14
Miscellaneous 12.79
Subtotal 441.82


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 73.65
Service Water Heating 0.00
Miscellaneous 0.00
Subtotal 73.65


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 7.33
Space Heating 14.29
Space Cooling 4.75
Fans-Interior 14.18
Service Water Heating 24.93
Receptacle Equipment 32.04
Miscellaneous 2.48



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 18:48:09

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.186914
G NW APARTMENT DIRECT AIR 0.149022
OFFICE DIRECT AIR 0.464218
G NE APARTMENT DIRECT AIR 0.100489
G N1 APARTMENT DIRECT AIR 0.076508
G N2 APARTMENT DIRECT AIR 0.075368
G S1 APARTMENT DIRECT AIR 0.132164
G S2 APARTMENT DIRECT AIR 0.135328
M SW APARTMENT DIRECT AIR 0.510889
M NW APARTMENT DIRECT AIR 0.409325
M SE APARTMENT DIRECT AIR 0.474774
M NE APARTMENT DIRECT AIR 0.304431
M N1 APARTMENT DIRECT AIR 0.226130
M N2 APARTMENT DIRECT AIR 0.224142
M S1 APARTMENT DIRECT AIR 0.373461
M S2 APARTMENT DIRECT AIR 0.374585
T SW APARTMENT DIRECT AIR 0.345815
T NW APARTMENT DIRECT AIR 0.275436
T SE APARTMENT DIRECT AIR 0.322136
T NE APARTMENT DIRECT AIR 0.218275
T N1 APARTMENT DIRECT AIR 0.169463
T N2 APARTMENT DIRECT AIR 0.169319
T S1 APARTMENT DIRECT AIR 0.270262
T S2 APARTMENT DIRECT AIR 0.271008


Branch

Maximum Flow Rate [m3/s]
SPLIT GSW MAIN BRANCH 0.186914
SPLIT GNW MAIN BRANCH 0.149022
SPLIT OFFICE MAIN BRANCH 0.464218
SPLIT GNE MAIN BRANCH 0.100489
SPLIT GN1 MAIN BRANCH 0.076508
SPLIT GN2 MAIN BRANCH 0.075368
SPLIT GS1 MAIN BRANCH 0.132164
SPLIT GS2 MAIN BRANCH 0.135328
SPLIT MSW MAIN BRANCH 0.510889
SPLIT MNW MAIN BRANCH 0.409325
SPLIT MSE MAIN BRANCH 0.474774
SPLIT MNE MAIN BRANCH 0.304431
SPLIT MN1 MAIN BRANCH 0.226130
SPLIT MN2 MAIN BRANCH 0.224142
SPLIT MS1 MAIN BRANCH 0.373461
SPLIT MS2 MAIN BRANCH 0.374585
SPLIT TSW MAIN BRANCH 0.345815
SPLIT TNW MAIN BRANCH 0.275436
SPLIT TSE MAIN BRANCH 0.322136
SPLIT TNE MAIN BRANCH 0.218275
SPLIT TN1 MAIN BRANCH 0.169463
SPLIT TN2 MAIN BRANCH 0.169319
SPLIT TS1 MAIN BRANCH 0.270262
SPLIT TS2 MAIN BRANCH 0.271008


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
SPLIT GSW 0.186914
SPLIT GNW 0.149022
SPLIT OFFICE 0.464218
SPLIT GNE 0.100489
SPLIT GN1 0.076508
SPLIT GN2 0.075368
SPLIT GS1 0.132164
SPLIT GS2 0.135328
SPLIT MSW 0.510889
SPLIT MNW 0.409325
SPLIT MSE 0.474774
SPLIT MNE 0.304431
SPLIT MN1 0.226130
SPLIT MN2 0.224142
SPLIT MS1 0.373461
SPLIT MS2 0.374585
SPLIT TSW 0.345815
SPLIT TNW 0.275436
SPLIT TSE 0.322136
SPLIT TNE 0.218275
SPLIT TN1 0.169463
SPLIT TN2 0.169319
SPLIT TS1 0.270262
SPLIT TS2 0.271008


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
SPLIT GSW OA CONTROLLER 0.186914 0.026898
SPLIT GNW OA CONTROLLER 0.149022 0.025953
SPLIT OFFICE OA CONTROLLER 0.464218 0.038104
SPLIT GNE OA CONTROLLER 0.100489 0.025953
SPLIT GN1 OA CONTROLLER 0.076508 0.025953
SPLIT GN2 OA CONTROLLER 0.075368 0.025953
SPLIT GS1 OA CONTROLLER 0.132164 0.025953
SPLIT GS2 OA CONTROLLER 0.135328 0.025953
SPLIT MSW OA CONTROLLER 0.510889 0.051906
SPLIT MNW OA CONTROLLER 0.409325 0.051906
SPLIT MSE OA CONTROLLER 0.474774 0.051906
SPLIT MNE OA CONTROLLER 0.304431 0.051906
SPLIT MN1 OA CONTROLLER 0.226130 0.051906
SPLIT MN2 OA CONTROLLER 0.224142 0.051906
SPLIT MS1 OA CONTROLLER 0.373461 0.051906
SPLIT MS2 OA CONTROLLER 0.374585 0.051906
SPLIT TSW OA CONTROLLER 0.345815 0.025953
SPLIT TNW OA CONTROLLER 0.275436 0.025953
SPLIT TSE OA CONTROLLER 0.322136 0.025953
SPLIT TNE OA CONTROLLER 0.218275 0.025953
SPLIT TN1 OA CONTROLLER 0.169463 0.025953
SPLIT TN2 OA CONTROLLER 0.169319 0.025953
SPLIT TS1 OA CONTROLLER 0.270262 0.025953
SPLIT TS2 OA CONTROLLER 0.271008 0.025953


Coil:Cooling:DX:SingleSpeed

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity (gross) [W] Rated Sensible Heat Ratio
SPLIT GSW COOLING COIL 0.186914 3245.56 0.781498
SPLIT GNW COOLING COIL 0.149022 2507.69 0.792668
SPLIT OFFICE COOLING COIL 0.464218 7684.46 0.798655
SPLIT GNE COOLING COIL 0.100489 1736.80 0.783129
SPLIT GN1 COOLING COIL 0.076508 1322.93 0.782970
SPLIT GN2 COOLING COIL 0.075368 1305.08 0.782462
SPLIT GS1 COOLING COIL 0.132164 2388.64 0.767740
SPLIT GS2 COOLING COIL 0.135328 2438.77 0.768713
SPLIT MSW COOLING COIL 0.510889 8582.99 0.793260
SPLIT MNW COOLING COIL 0.409325 6775.78 0.798655
SPLIT MSE COOLING COIL 0.474774 8143.90 0.785803
SPLIT MNE COOLING COIL 0.304431 5072.00 0.796293
SPLIT MN1 COOLING COIL 0.226130 3783.21 0.794772
SPLIT MN2 COOLING COIL 0.224142 3752.42 0.794532
SPLIT MS1 COOLING COIL 0.373461 6540.08 0.778531
SPLIT MS2 COOLING COIL 0.374585 6557.94 0.778629
SPLIT TSW COOLING COIL 0.345815 5777.49 0.795281
SPLIT TNW COOLING COIL 0.275436 4559.44 0.798655
SPLIT TSE COOLING COIL 0.322136 5438.17 0.791511
SPLIT TNE COOLING COIL 0.218275 3786.67 0.781816
SPLIT TN1 COOLING COIL 0.169463 2986.63 0.776323
SPLIT TN2 COOLING COIL 0.169319 2984.28 0.776301
SPLIT TS1 COOLING COIL 0.270262 4602.08 0.788407
SPLIT TS2 COOLING COIL 0.271008 4614.03 0.788465


AirLoopHVAC:Unitary:Furnace:HeatCool

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
SPLIT GSW FURNACE WITH DX COOLING 0.186914 0.186914 0.186914 0.186914 2140.09 3245.56 1.00
SPLIT GNW FURNACE WITH DX COOLING 0.149022 0.149022 0.149022 0.149022 2117.83 2507.69 1.00
SPLIT OFFICE FURNACE WITH DX COOLING 0.464218 0.464218 0.464218 0.464218 3966.80 7684.46 1.00
SPLIT GNE FURNACE WITH DX COOLING 0.100489 0.100489 0.100489 0.100489 2117.83 1736.80 1.00
SPLIT GN1 FURNACE WITH DX COOLING 0.076508 0.076508 0.076508 0.076508 1733.86 1322.93 1.00
SPLIT GN2 FURNACE WITH DX COOLING 0.075368 0.075368 0.075368 0.075368 1733.86 1305.08 1.00
SPLIT GS1 FURNACE WITH DX COOLING 0.132164 0.132164 0.132164 0.132164 1733.86 2388.64 1.00
SPLIT GS2 FURNACE WITH DX COOLING 0.135328 0.135328 0.135328 0.135328 1733.86 2438.77 1.00
SPLIT MSW FURNACE WITH DX COOLING 0.510889 0.510889 0.510889 0.510889 4028.96 8582.99 1.00
SPLIT MNW FURNACE WITH DX COOLING 0.409325 0.409325 0.409325 0.409325 4048.78 6775.78 1.00
SPLIT MSE FURNACE WITH DX COOLING 0.474774 0.474774 0.474774 0.474774 4028.96 8143.90 1.00
SPLIT MNE FURNACE WITH DX COOLING 0.304431 0.304431 0.304431 0.304431 4048.78 5072.00 1.00
SPLIT MN1 FURNACE WITH DX COOLING 0.226130 0.226130 0.226130 0.226130 3467.71 3783.21 1.00
SPLIT MN2 FURNACE WITH DX COOLING 0.224142 0.224142 0.224142 0.224142 3467.71 3752.42 1.00
SPLIT MS1 FURNACE WITH DX COOLING 0.373461 0.373461 0.373461 0.373461 3467.71 6540.08 1.00
SPLIT MS2 FURNACE WITH DX COOLING 0.374585 0.374585 0.374585 0.374585 3467.71 6557.94 1.00
SPLIT TSW FURNACE WITH DX COOLING 0.345815 0.345815 0.345815 0.345815 3146.11 5777.49 1.00
SPLIT TNW FURNACE WITH DX COOLING 0.275436 0.275436 0.275436 0.275436 3158.16 4559.44 1.00
SPLIT TSE FURNACE WITH DX COOLING 0.322136 0.322136 0.322136 0.322136 3146.11 5438.17 1.00
SPLIT TNE FURNACE WITH DX COOLING 0.218275 0.218275 0.218275 0.218275 3158.16 3786.67 1.00
SPLIT TN1 FURNACE WITH DX COOLING 0.169463 0.169463 0.169463 0.169463 2472.26 2986.63 1.00
SPLIT TN2 FURNACE WITH DX COOLING 0.169319 0.169319 0.169319 0.169319 2472.26 2984.28 1.00
SPLIT TS1 FURNACE WITH DX COOLING 0.270262 0.270262 0.270262 0.270262 2458.18 4602.08 1.00
SPLIT TS2 FURNACE WITH DX COOLING 0.271008 0.271008 0.271008 0.271008 2458.18 4614.03 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
SPLIT GSW SUPPLY FAN 0.186914
SPLIT GNW SUPPLY FAN 0.149022
SPLIT OFFICE SUPPLY FAN 0.464218
SPLIT GNE SUPPLY FAN 0.100489
SPLIT GN1 SUPPLY FAN 0.076508
SPLIT GN2 SUPPLY FAN 0.075368
SPLIT GS1 SUPPLY FAN 0.132164
SPLIT GS2 SUPPLY FAN 0.135328
SPLIT MSW SUPPLY FAN 0.510889
SPLIT MNW SUPPLY FAN 0.409325
SPLIT MSE SUPPLY FAN 0.474774
SPLIT MNE SUPPLY FAN 0.304431
SPLIT MN1 SUPPLY FAN 0.226130
SPLIT MN2 SUPPLY FAN 0.224142
SPLIT MS1 SUPPLY FAN 0.373461
SPLIT MS2 SUPPLY FAN 0.374585
SPLIT TSW SUPPLY FAN 0.345815
SPLIT TNW SUPPLY FAN 0.275436
SPLIT TSE SUPPLY FAN 0.322136
SPLIT TNE SUPPLY FAN 0.218275
SPLIT TN1 SUPPLY FAN 0.169463
SPLIT TN2 SUPPLY FAN 0.169319
SPLIT TS1 SUPPLY FAN 0.270262
SPLIT TS2 SUPPLY FAN 0.271008


Coil:Heating:Gas

Nominal Capacity [W]
SPLIT GSW HEATING COIL 2140.09
SPLIT GNW HEATING COIL 2117.83
SPLIT OFFICE HEATING COIL 3966.80
SPLIT GNE HEATING COIL 2117.83
SPLIT GN1 HEATING COIL 1733.86
SPLIT GN2 HEATING COIL 1733.86
SPLIT GS1 HEATING COIL 1733.86
SPLIT GS2 HEATING COIL 1733.86
SPLIT MSW HEATING COIL 4028.96
SPLIT MNW HEATING COIL 4048.78
SPLIT MSE HEATING COIL 4028.96
SPLIT MNE HEATING COIL 4048.78
SPLIT MN1 HEATING COIL 3467.71
SPLIT MN2 HEATING COIL 3467.71
SPLIT MS1 HEATING COIL 3467.71
SPLIT MS2 HEATING COIL 3467.71
SPLIT TSW HEATING COIL 3146.11
SPLIT TNW HEATING COIL 3158.16
SPLIT TSE HEATING COIL 3146.11
SPLIT TNE HEATING COIL 3158.16
SPLIT TN1 HEATING COIL 2472.26
SPLIT TN2 HEATING COIL 2472.26
SPLIT TS1 HEATING COIL 2458.18
SPLIT TS2 HEATING COIL 2458.18



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2015-09-09 18:48:09

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW1 S SWA |
G WWALL SWA GWINDOW1 W SWA |
G NWALL NWA GWINDOW1 N NWA |
G WWALL NWA GWINDOW1 W NWA |
G SWALL SEA GWINDOW1 S SEA |
G EWALL SEA GWINDOW1 E SEA |
G NWALL NEA GWINDOW1 N NEA |
G EWALL NEA GWINDOW1 E NEA |
G NWALL N1A GWINDOW1 N N1A |
G NWALL N2A GWINDOW1 N N2A |
G SWALL S1A GWINDOW1 S S1A |
G SWALL S2A GWINDOW1 S S2A |
M WWALL SWA MWINDOW1 W SWA |
M SWALL SWA MWINDOW1 S SWA |
M NWALL NWA MWINDOW1 N NWA |
M WWALL NWA MWINDOW1 W NWA |
M EWALL SEA MWINDOW1 E SEA |
M SWALL SEA MWINDOW1 S SEA |
M NWALL NEA MWINDOW1 N NEA |
M EWALL NEA MWINDOW1 E NEA |
M NWALL N1A MWINDOW1 N N1A |
M NWALL N2A MWINDOW1 N N2A |
M SWALL S1A MWINDOW1 S S1A |
M SWALL S2A MWINDOW1 S S2A |
T WWALL SWA TWINDOW1 W SWA |
T SWALL SWA TWINDOW1 S SWA |
T NWALL NWA TWINDOW1 N NWA |
T WWALL NWA TWINDOW1 W NWA |
T EWALL SEA TWINDOW1 E SEA |
T SWALL SEA TWINDOW1 S SEA |
T NWALL NEA TWINDOW1 N NEA |
T EWALL NEA TWINDOW1 E NEA |
T NWALL N1A TWINDOW1 N N1A |
T NWALL N2A TWINDOW1 N N2A |
T SWALL S1A TWINDOW1 S S1A |
T SWALL S2A TWINDOW1 S S2A |
T EWALL C TWINDOW14 |
G EWALL C ENTRANCE DOOR |
M EWALL C MWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2015-09-09 18:48:09

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.77 4.90
February 21.85 5.21
March 22.10 8.41
April 22.30 10.40
May 22.76 13.39
June 24.04 17.41
July 24.28 20.12
August 24.33 19.46
September 24.18 16.66
October 22.58 11.27
November 21.81 8.49
December 21.74 4.55
     
Annual Sum or Average 22.82 11.73
Minimum of Months 21.74 4.55
Maximum of Months 24.33 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.90
February 21.73 5.21
March 21.82 8.41
April 22.05 10.40
May 22.53 13.39
June 23.96 17.41
July 24.25 20.12
August 24.27 19.46
September 23.99 16.66
October 22.14 11.27
November 21.72 8.49
December 21.70 4.55
     
Annual Sum or Average 22.66 11.73
Minimum of Months 21.70 4.55
Maximum of Months 24.27 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.53 4.90
February 21.36 5.21
March 22.62 8.41
April 22.95 10.40
May 23.72 13.39
June 25.35 17.41
July 25.99 20.12
August 25.88 19.46
September 25.72 16.66
October 23.46 11.27
November 22.29 8.49
December 21.17 4.55
     
Annual Sum or Average 23.51 11.73
Minimum of Months 21.17 4.55
Maximum of Months 25.99 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.90
February 21.71 5.21
March 21.77 8.41
April 21.98 10.40
May 22.42 13.39
June 23.86 17.41
July 24.21 20.12
August 24.22 19.46
September 23.92 16.66
October 22.04 11.27
November 21.70 8.49
December 21.70 4.55
     
Annual Sum or Average 22.61 11.73
Minimum of Months 21.70 4.55
Maximum of Months 24.22 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.90
February 21.71 5.21
March 21.75 8.41
April 21.92 10.40
May 22.30 13.39
June 23.87 17.41
July 24.21 20.12
August 24.23 19.46
September 23.94 16.66
October 22.04 11.27
November 21.71 8.49
December 21.70 4.55
     
Annual Sum or Average 22.59 11.73
Minimum of Months 21.70 4.55
Maximum of Months 24.23 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 4.90
February 21.71 5.21
March 21.75 8.41
April 21.92 10.40
May 22.29 13.39
June 23.86 17.41
July 24.20 20.12
August 24.22 19.46
September 23.94 16.66
October 22.04 11.27
November 21.71 8.49
December 21.70 4.55
     
Annual Sum or Average 22.59 11.73
Minimum of Months 21.70 4.55
Maximum of Months 24.22 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.78 4.90
February 21.85 5.21
March 22.08 8.41
April 22.23 10.40
May 22.66 13.39
June 24.04 17.41
July 24.28 20.12
August 24.34 19.46
September 24.23 16.66
October 22.64 11.27
November 21.84 8.49
December 21.75 4.55
     
Annual Sum or Average 22.81 11.73
Minimum of Months 21.75 4.55
Maximum of Months 24.34 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.78 4.90
February 21.85 5.21
March 22.09 8.41
April 22.25 10.40
May 22.69 13.39
June 24.07 17.41
July 24.30 20.12
August 24.35 19.46
September 24.25 16.66
October 22.66 11.27
November 21.85 8.49
December 21.75 4.55
     
Annual Sum or Average 22.83 11.73
Minimum of Months 21.75 4.55
Maximum of Months 24.35 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.00 4.90
February 22.15 5.21
March 23.40 8.41
April 23.59 10.40
May 24.23 13.39
June 24.39 17.41
July 24.40 20.12
August 24.40 19.46
September 24.40 16.66
October 23.95 11.27
November 22.48 8.49
December 21.91 4.55
     
Annual Sum or Average 23.45 11.73
Minimum of Months 21.91 4.55
Maximum of Months 24.40 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 4.90
February 21.82 5.21
March 22.78 8.41
April 23.10 10.40
May 24.14 13.39
June 24.38 17.41
July 24.39 20.12
August 24.40 19.46
September 24.37 16.66
October 23.35 11.27
November 21.95 8.49
December 21.72 4.55
     
Annual Sum or Average 23.19 11.73
Minimum of Months 21.72 4.55
Maximum of Months 24.40 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.99 4.90
February 22.11 5.21
March 23.35 8.41
April 23.49 10.40
May 24.21 13.39
June 24.38 17.41
July 24.39 20.12
August 24.40 19.46
September 24.39 16.66
October 23.91 11.27
November 22.42 8.49
December 21.89 4.55
     
Annual Sum or Average 23.42 11.73
Minimum of Months 21.89 4.55
Maximum of Months 24.40 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.78 5.21
March 22.63 8.41
April 22.99 10.40
May 24.05 13.39
June 24.36 17.41
July 24.39 20.12
August 24.40 19.46
September 24.35 16.66
October 23.11 11.27
November 21.85 8.49
December 21.71 4.55
     
Annual Sum or Average 23.12 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.40 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 4.90
February 21.81 5.21
March 22.83 8.41
April 23.11 10.40
May 24.20 13.39
June 24.39 17.41
July 24.40 20.12
August 24.40 19.46
September 24.38 16.66
October 23.50 11.27
November 22.06 8.49
December 21.74 4.55
     
Annual Sum or Average 23.22 11.73
Minimum of Months 21.73 4.55
Maximum of Months 24.40 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.73 4.90
February 21.80 5.21
March 22.81 8.41
April 23.09 10.40
May 24.19 13.39
June 24.39 17.41
July 24.40 20.12
August 24.40 19.46
September 24.38 16.66
October 23.46 11.27
November 22.05 8.49
December 21.74 4.55
     
Annual Sum or Average 23.21 11.73
Minimum of Months 21.73 4.55
Maximum of Months 24.40 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.21 4.90
February 22.31 5.21
March 23.69 8.41
April 23.81 10.40
May 24.31 13.39
June 24.40 17.41
July 24.40 20.12
August 24.40 19.46
September 24.40 16.66
October 24.16 11.27
November 22.91 8.49
December 22.04 4.55
     
Annual Sum or Average 23.59 11.73
Minimum of Months 22.04 4.55
Maximum of Months 24.40 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.21 4.90
February 22.31 5.21
March 23.69 8.41
April 23.80 10.40
May 24.31 13.39
June 24.40 17.41
July 24.40 20.12
August 24.40 19.46
September 24.40 16.66
October 24.16 11.27
November 22.91 8.49
December 22.04 4.55
     
Annual Sum or Average 23.59 11.73
Minimum of Months 22.04 4.55
Maximum of Months 24.40 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.89 4.90
February 22.02 5.21
March 22.71 8.41
April 23.00 10.40
May 23.66 13.39
June 24.20 17.41
July 24.31 20.12
August 24.34 19.46
September 24.17 16.66
October 23.04 11.27
November 22.06 8.49
December 21.86 4.55
     
Annual Sum or Average 23.11 11.73
Minimum of Months 21.86 4.55
Maximum of Months 24.34 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.72 4.90
February 21.81 5.21
March 22.29 8.41
April 22.69 10.40
May 23.47 13.39
June 24.12 17.41
July 24.27 20.12
August 24.28 19.46
September 23.96 16.66
October 22.57 11.27
November 21.79 8.49
December 21.72 4.55
     
Annual Sum or Average 22.90 11.73
Minimum of Months 21.72 4.55
Maximum of Months 24.28 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.89 4.90
February 22.00 5.21
March 22.68 8.41
April 22.97 10.40
May 23.64 13.39
June 24.17 17.41
July 24.30 20.12
August 24.33 19.46
September 24.15 16.66
October 23.02 11.27
November 22.03 8.49
December 21.85 4.55
     
Annual Sum or Average 23.09 11.73
Minimum of Months 21.85 4.55
Maximum of Months 24.33 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.77 5.21
March 22.22 8.41
April 22.60 10.40
May 23.39 13.39
June 24.04 17.41
July 24.23 20.12
August 24.24 19.46
September 23.90 16.66
October 22.45 11.27
November 21.74 8.49
December 21.71 4.55
     
Annual Sum or Average 22.84 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.24 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.77 5.21
March 22.23 8.41
April 22.66 10.40
May 23.50 13.39
June 24.14 17.41
July 24.27 20.12
August 24.27 19.46
September 23.96 16.66
October 22.52 11.27
November 21.78 8.49
December 21.72 4.55
     
Annual Sum or Average 22.88 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.27 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.71 4.90
February 21.77 5.21
March 22.23 8.41
April 22.65 10.40
May 23.49 13.39
June 24.13 17.41
July 24.27 20.12
August 24.27 19.46
September 23.95 16.66
October 22.51 11.27
November 21.78 8.49
December 21.72 4.55
     
Annual Sum or Average 22.88 11.73
Minimum of Months 21.71 4.55
Maximum of Months 24.27 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.94 4.90
February 22.06 5.21
March 22.82 8.41
April 23.12 10.40
May 23.79 13.39
June 24.26 17.41
July 24.34 20.12
August 24.37 19.46
September 24.23 16.66
October 23.21 11.27
November 22.17 8.49
December 21.90 4.55
     
Annual Sum or Average 23.19 11.73
Minimum of Months 21.90 4.55
Maximum of Months 24.37 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.94 4.90
February 22.06 5.21
March 22.82 8.41
April 23.11 10.40
May 23.79 13.39
June 24.26 17.41
July 24.34 20.12
August 24.37 19.46
September 24.23 16.66
October 23.21 11.27
November 22.17 8.49
December 21.90 4.55
     
Annual Sum or Average 23.19 11.73
Minimum of Months 21.90 4.55
Maximum of Months 24.37 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.64 4.90
February 21.78 5.21
March 23.10 8.41
April 23.75 10.40
May 24.95 13.39
June 25.96 17.41
July 26.37 20.12
August 26.24 19.46
September 25.66 16.66
October 23.64 11.27
November 22.20 8.49
December 21.46 4.55
     
Annual Sum or Average 23.91 11.73
Minimum of Months 21.46 4.55
Maximum of Months 26.37 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 19.51 4.90
February 19.62 5.21
March 20.61 8.41
April 21.23 10.40
May 22.28 13.39
June 24.64 17.41
July 25.58 20.12
August 25.46 19.46
September 24.71 16.66
October 21.77 11.27
November 20.39 8.49
December 19.39 4.55
     
Annual Sum or Average 22.11 11.73
Minimum of Months 19.39 4.55
Maximum of Months 25.58 20.12



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2015-09-09 18:48:09

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.23 4.90
February 23.29 5.21
March 24.85 8.41
April 25.13 10.40
May 26.20 13.39
June 26.60 17.41
July 26.76 20.12
August 26.71 19.46
September 26.56 16.66
October 25.53 11.27
November 23.81 8.49
December 23.01 4.55
     
Annual Sum or Average 25.15 11.73
Minimum of Months 23.01 4.55
Maximum of Months 26.76 20.12



Table of Contents

Report: PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2015-09-09 18:48:09

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY [Invalid/Undefined] HEATREJECTION:ELECTRICITY [Invalid/Undefined] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined]
January 0.114135E+12 73511.662 13-JAN-18:00 4979.953 26630.920 7266.229 0.000 0.000 2553.000 0.000 0.000 0.000 0.000 0.000 32081.559 0.000 0.000 0.000
February 0.103215E+12 71901.326 13-FEB-18:15 4979.953 26630.920 7266.229 0.000 0.000 2553.000 0.000 0.000 0.000 0.000 0.000 30471.223 0.000 0.000 0.000
March 0.114695E+12 68933.484 20-MAR-17:30 4979.953 26630.920 7266.229 0.000 6047.468 0.000 0.000 0.000 0.000 0.000 0.000 24008.913 0.000 0.000 0.000
April 0.110873E+12 71755.860 22-APR-17:45 4979.953 26630.920 7266.229 0.000 6244.635 0.000 0.000 0.000 0.000 0.000 0.000 26634.123 0.000 0.000 0.000
May 0.116493E+12 75091.361 04-MAY-17:15 4979.953 26630.920 7266.229 0.000 12786.661 0.000 0.000 0.000 0.000 0.000 0.000 23427.597 0.000 0.000 0.000
June 0.118017E+12 80553.131 24-JUN-17:30 4979.953 26630.920 7266.229 0.000 20577.148 0.000 0.000 0.000 0.000 0.000 0.000 21098.880 0.000 0.000 0.000
July 0.127738E+12 84248.103 18-JUL-16:15 4276.255 26730.986 7266.229 0.000 23107.304 0.000 0.000 0.000 0.000 0.000 0.000 22867.328 0.000 0.000 0.000
August 0.126156E+12 80307.818 01-AUG-17:00 4979.953 26630.920 7266.229 0.000 16338.845 0.000 0.000 0.000 0.000 0.000 0.000 25091.871 0.000 0.000 0.000
September 0.117706E+12 78309.224 09-SEP-17:00 4979.953 26630.920 7266.229 0.000 15144.172 0.000 0.000 0.000 0.000 0.000 0.000 24287.949 0.000 0.000 0.000
October 0.113823E+12 69768.954 02-OCT-17:45 4979.953 26630.920 7266.229 0.000 4254.251 0.000 0.000 0.000 0.000 0.000 0.000 26637.600 0.000 0.000 0.000
November 0.108700E+12 68436.201 24-NOV-18:15 4979.953 26630.920 7266.229 0.000 0.000 2553.000 0.000 0.000 0.000 0.000 0.000 27006.098 0.000 0.000 0.000
December 0.113374E+12 68480.687 31-DEC-18:15 4979.953 26630.920 7266.229 0.000 0.000 2553.000 0.000 0.000 0.000 0.000 0.000 27050.585 0.000 0.000 0.000
                                     
Annual Sum or Average 0.138493E+13                 0.000 0.000 0.000 0.000 0.000   0.000 0.000 0.000
Minimum of Months 0.103215E+12 68436.201   4276.255 26630.920 7266.229 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 21098.880 0.000 0.000 0.000
Maximum of Months 0.127738E+12 84248.103   4979.953 26730.986 7266.229 0.000 23107.304 2553.000 0.000 0.000 0.000 0.000 0.000 32081.559 0.000 0.000 0.000



Table of Contents

Report: PEAK GAS DEMAND

For: Meter

Timestamp: 2015-09-09 18:48:09

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC {AT MAX/MIN} [W] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT [Invalid/Undefined] WATERSYSTEMS:GAS [Invalid/Undefined] WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] HEATING:GAS {AT MAX/MIN} [W]
January 0.502954E+11 45733.910 01-JAN-03:00 45733.910 0.000 0.000 0.000 0.000 0.000 45733.910
February 0.544977E+11 78560.181 15-FEB-01:00 78560.181 0.000 0.000 0.000 0.000 0.000 78560.181
March 0.161607E+11 36846.239 03-MAR-05:00 36846.239 0.000 0.000 0.000 0.000 0.000 36846.239
April 0.104138E+11 30903.388 11-APR-03:00 30903.388 0.000 0.000 0.000 0.000 0.000 30903.388
May 0.222133E+10 12593.766 24-MAY-03:00 12593.766 0.000 0.000 0.000 0.000 0.000 12593.766
June 230191.391 55.022 17-JUN-05:30 55.022 0.000 0.000 0.000 0.000 0.000 55.022
July 0.000 0.000 01-JUL-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 0.000 0.000 01-AUG-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
September 2163274.429 213.416 15-SEP-04:00 213.416 0.000 0.000 0.000 0.000 0.000 213.416
October 0.644920E+10 26209.658 30-OCT-02:15 26209.658 0.000 0.000 0.000 0.000 0.000 26209.658
November 0.249646E+11 34728.805 30-NOV-05:00 34728.805 0.000 0.000 0.000 0.000 0.000 34728.805
December 0.658677E+11 78565.154 20-DEC-04:00 78565.154 0.000 0.000 0.000 0.000 0.000 78565.154
                     
Annual Sum or Average 0.230873E+12       0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.000 0.000   0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.658677E+11 78565.154   78565.154 0.000 0.000 0.000 0.000 0.000 78565.154