Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:47
Tabular Output Report in Format: HTML
Building: Mid-Rise Apartment
Environment: Albuquerque Intl Arpt Isis NM USA TMY3 WMO#=723650
Simulation Timestamp: 2015-09-09 18:47:12
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:12
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1599.19 | 510.17 | 566.29 |
Net Site Energy | 1599.19 | 510.17 | 566.29 |
Total Source Energy | 4799.71 | 1531.20 | 1699.63 |
Net Source Energy | 4799.71 | 1531.20 | 1699.63 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 3134.61 |
Net Conditioned Building Area | 2823.98 |
Unconditioned Building Area | 310.64 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 127.18 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 147.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 118.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 40.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 517.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 264.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 383.84 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1472.01 | 127.18 | 0.00 | 0.00 | 0.00 | 1874.72 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 127.18 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 147.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 96.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 22.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 40.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 517.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 264.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 383.84 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 56.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 281.79 | 45.04 | 0.00 | 0.00 | 0.00 | 0.66 |
Other | 183.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 521.25 | 45.04 | 0.00 | 0.00 | 0.00 | 0.66 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 50.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 253.87 | 40.57 | 0.00 | 0.00 | 0.00 | 0.60 |
Other | 165.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 469.60 | 40.57 | 0.00 | 0.00 | 0.00 | 0.60 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 1472.01 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 1472.01 | 100.00 |
Total On-Site and Utility Electric Sources | 1472.01 | 100.00 |
Total Electricity End Uses | 1472.01 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 1874.72 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 1874.72 | 100.00 |
Total Water End Uses | 1874.72 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 35.75 |
Time Setpoint Not Met During Occupied Cooling | 2.25 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 1544.75 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PEAK ELECTRICAL DEMAND
| Meter |PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:12
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:47 |
RunPeriod | Albuquerque Intl Arpt Isis NM USA TMY3 WMO#=723650 |
Weather File | Albuquerque Intl Arpt Isis NM USA TMY3 WMO#=723650 |
Latitude [deg] | 35.04 |
Longitude [deg] | -106.6 |
Elevation [m] | 1619.00 |
Time Zone | -7.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
Window Opening Area [m2] | 306.92 | 112.97 | 37.16 | 112.97 | 43.82 |
Window-Wall Ratio [%] | 19.90 | 20.00 | 18.02 | 20.00 | 21.25 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 26.1977 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 1.11 | 5.9540 | 0.0000 | |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 3.32 | 5.9540 | 208.8202 | |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 1.11 | 5.9540 | 0.0000 | |
Total | 3134.61 | 9553.84 | 1542.04 | 306.92 | 4.5346 | 39.93 | 11.1825 | |||
Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 300.26 | 4.3785 | 35.97 | 6.6700 | |||
Unconditioned Total | 310.64 | 946.78 | 40.87 | 6.66 | 5.9540 | 52.2051 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:12
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 21-JUL-17:30 | 18-JAN-01:15 | - | - | - | 01-JAN-07:15 |
Heating | 0.00 | 60925.70 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 22755.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 4979.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 26630.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 8400.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 19573.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 82340.84 | 60925.70 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 60925.70 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 22755.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 4056.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 923.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 26630.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 8400.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 19573.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:12
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 137.86 | 0.00 | 0.00 | 0.00 |
Cooling | 465.58 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 375.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 127.04 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1639.40 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 839.04 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 1215.61 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 4661.85 | 137.86 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 48.82 | 0.00 | 0.00 | 0.00 |
Cooling | 164.87 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 132.85 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.99 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 580.53 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 297.11 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 430.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1650.81 | 48.82 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 48.82 | 0.00 | 0.00 | 0.00 |
Cooling | 164.87 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 132.85 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.99 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 580.53 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 297.11 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 430.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1650.81 | 48.82 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:12
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | -7.90 | 0.00 | -7.90 | Wetbulb [C] | 3.20 | 0.00 |
ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 35.10 | 13.50 | 15.70 | Wetbulb [C] | 4.40 | 220.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:12
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.30 | 0.269 | 0.283 | 77.66 | 180.00 | 0.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 90.00 | 180.00 | |
M WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.22 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.22 | 90.00 | 90.00 | E |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW1 S SWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW1 W SWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW1 N NWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW1 W NWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 S SEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW1 E SEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW1 N NEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW1 E NEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW1 N N1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW1 N N2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW1 S S1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW1 S S2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW1 W SWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.653 | 0.426 | 0.308 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW1 S SWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW1 N NWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW1 W NWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.653 | 0.426 | 0.308 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW1 E SEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.653 | 0.426 | 0.308 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 S SEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW1 N NEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW1 E NEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.653 | 0.426 | 0.308 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW1 N N1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW1 N N2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW1 S S1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW1 S S2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW1 W SWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW1 S SWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW1 N NWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW1 W NWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW1 E SEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 S SEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW1 N NEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW1 E NEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW1 N N1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW1 N N2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW1 S S1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW1 S S2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW14 | WINDOW_U_0.52_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | T EWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_0.52_SHGC_0.40 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 2.653 | 0.426 | 0.308 | No | G EWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_0.52_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 2.653 | 0.426 | 0.308 | No | M EWALL C | 270.00 | 90.00 | W | ||
Total or Average | 306.92 | 2.653 | 0.426 | 0.308 | ||||||||||||
North Total or Average | 112.97 | 2.653 | 0.426 | 0.308 | ||||||||||||
Non-North Total or Average | 193.95 | 2.653 | 0.426 | 0.308 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:12
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:12
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
LIGHTING_HARDWIRED_GSW | G SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GNW | G NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_OFFICE | OFFICE | 13.0989 | 88.25 | 1155.96 | GeneralLights | LTG_OFF_SCH | 62.17 | 168.00 | 60.95 | 0.0000 | Y | 13.23 |
LIGHTING_HARDWIRED_GNE | G NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MSW | M SW APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MNW | M NW APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MSE | M SE APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MNE | M NE APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TSW | T SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TNW | T NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TSE | T SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TNE | T NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GC | G CORRIDOR | 5.9540 | 77.66 | 462.39 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 14.58 |
LIGHTING_HARDWIRED_MC | M CORRIDOR | 5.9540 | 155.32 | 924.77 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 14.58 |
LIGHTING_HARDWIRED_TC | T CORRIDOR | 5.9540 | 77.66 | 462.39 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 14.58 |
LIGHTING_PLUGIN_GSW | G SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_GNW | G NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_OFFICE | OFFICE | 13.0989 | 88.25 | 1155.96 | GeneralLights-plugin | LTG_OFF_SCH | 62.17 | 168.00 | 60.95 | 0.0000 | Y | 13.23 |
LIGHTING_PLUGIN_GNE | G NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MSW | M SW APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MNW | M NW APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MSE | M SE APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MNE | M NE APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TSW | T SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TNW | T NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TSE | T SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TNE | T NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
Interior Lighting Total | 2.3855 | 5958.59 | 14214.30 | 95.19 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 2553.00 | AstronomicalClock | - | 83.70 | 83.70 | 40.11 | |
Exterior Lighting Total | 2553.00 | 40.11 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:12
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3368.49 | 2690.27 | 678.23 | 0.80 | 3.91 | |||
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3325.89 | 2656.24 | 669.65 | 0.80 | 3.91 | |||
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9057.32 | 7233.67 | 1823.64 | 0.80 | 3.91 | |||
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2450.59 | 1957.18 | 493.41 | 0.80 | 3.91 | |||
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1911.29 | 1526.46 | 384.83 | 0.80 | 3.91 | |||
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1890.11 | 1509.55 | 380.56 | 0.80 | 3.91 | |||
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1909.42 | 1524.97 | 384.45 | 0.80 | 3.91 | |||
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1967.40 | 1571.27 | 396.13 | 0.80 | 3.91 | |||
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9050.38 | 7228.13 | 1822.25 | 0.80 | 3.91 | |||
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8898.57 | 7106.89 | 1791.68 | 0.80 | 3.91 | |||
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7678.31 | 6132.32 | 1545.99 | 0.80 | 3.91 | |||
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6992.17 | 5584.34 | 1407.84 | 0.80 | 3.91 | |||
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5342.45 | 4266.78 | 1075.67 | 0.80 | 3.91 | |||
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5307.36 | 4238.75 | 1068.61 | 0.80 | 3.91 | |||
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5473.34 | 4371.31 | 1102.03 | 0.80 | 3.91 | |||
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5493.45 | 4387.38 | 1106.08 | 0.80 | 3.91 | |||
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6258.47 | 4998.36 | 1260.11 | 0.80 | 3.91 | |||
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6052.20 | 4833.62 | 1218.58 | 0.80 | 3.91 | |||
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5598.59 | 4471.34 | 1127.25 | 0.80 | 3.91 | |||
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5022.19 | 4011.00 | 1011.19 | 0.80 | 3.91 | |||
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3915.49 | 3127.12 | 788.36 | 0.80 | 3.91 | |||
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3917.43 | 3128.67 | 788.75 | 0.80 | 3.91 | |||
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4452.89 | 3556.32 | 896.57 | 0.80 | 3.91 | |||
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4464.02 | 3565.21 | 898.81 | 0.80 | 3.91 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3209.0 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3168.4 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8628.5 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2334.6 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1820.8 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1800.6 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1819.0 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1874.3 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8621.9 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8477.3 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7314.8 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6661.1 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5089.5 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5056.1 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5214.2 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5233.4 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5962.2 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5765.7 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5333.5 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4784.4 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3730.1 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3732.0 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4242.1 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4252.7 | 3.13 | 10.67 | 11.09 | 10.38 |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
SPLIT GSW HEATING COIL | Coil:Heating:Gas | 2219.07 | 0.80 | |
SPLIT GNW HEATING COIL | Coil:Heating:Gas | 2201.53 | 0.80 | |
SPLIT OFFICE HEATING COIL | Coil:Heating:Gas | 4091.08 | 0.80 | |
SPLIT GNE HEATING COIL | Coil:Heating:Gas | 2201.53 | 0.80 | |
SPLIT GN1 HEATING COIL | Coil:Heating:Gas | 1610.17 | 0.80 | |
SPLIT GN2 HEATING COIL | Coil:Heating:Gas | 1610.17 | 0.80 | |
SPLIT GS1 HEATING COIL | Coil:Heating:Gas | 1601.92 | 0.80 | |
SPLIT GS2 HEATING COIL | Coil:Heating:Gas | 1701.15 | 0.80 | |
SPLIT MSW HEATING COIL | Coil:Heating:Gas | 4382.89 | 0.80 | |
SPLIT MNW HEATING COIL | Coil:Heating:Gas | 4407.95 | 0.80 | |
SPLIT MSE HEATING COIL | Coil:Heating:Gas | 4382.89 | 0.80 | |
SPLIT MNE HEATING COIL | Coil:Heating:Gas | 4407.95 | 0.80 | |
SPLIT MN1 HEATING COIL | Coil:Heating:Gas | 2990.99 | 0.80 | |
SPLIT MN2 HEATING COIL | Coil:Heating:Gas | 2990.99 | 0.80 | |
SPLIT MS1 HEATING COIL | Coil:Heating:Gas | 2990.99 | 0.80 | |
SPLIT MS2 HEATING COIL | Coil:Heating:Gas | 2990.99 | 0.80 | |
SPLIT TSW HEATING COIL | Coil:Heating:Gas | 3428.01 | 0.80 | |
SPLIT TNW HEATING COIL | Coil:Heating:Gas | 3442.67 | 0.80 | |
SPLIT TSE HEATING COIL | Coil:Heating:Gas | 3428.01 | 0.80 | |
SPLIT TNE HEATING COIL | Coil:Heating:Gas | 3442.67 | 0.80 | |
SPLIT TN1 HEATING COIL | Coil:Heating:Gas | 2638.78 | 0.80 | |
SPLIT TN2 HEATING COIL | Coil:Heating:Gas | 2638.78 | 0.80 | |
SPLIT TS1 HEATING COIL | Coil:Heating:Gas | 2622.14 | 0.80 | |
SPLIT TS2 HEATING COIL | Coil:Heating:Gas | 2622.14 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.20 | 236.22 | 1160.84 | 1.00 | General |
SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.20 | 233.23 | 1160.84 | 1.00 | General |
SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.55 | 635.16 | 1160.84 | 1.00 | General |
SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 171.85 | 1160.84 | 1.00 | General |
SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.12 | 134.03 | 1160.84 | 1.00 | General |
SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.11 | 132.55 | 1160.84 | 1.00 | General |
SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.12 | 133.90 | 1160.84 | 1.00 | General |
SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.12 | 137.97 | 1160.84 | 1.00 | General |
SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.55 | 634.67 | 1160.84 | 1.00 | General |
SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.54 | 624.02 | 1160.84 | 1.00 | General |
SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.46 | 538.45 | 1160.84 | 1.00 | General |
SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.42 | 490.34 | 1160.84 | 1.00 | General |
SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 374.65 | 1160.84 | 1.00 | General |
SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 372.19 | 1160.84 | 1.00 | General |
SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 383.83 | 1160.84 | 1.00 | General |
SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 385.24 | 1160.84 | 1.00 | General |
SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.38 | 438.88 | 1160.84 | 1.00 | General |
SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.37 | 424.42 | 1160.84 | 1.00 | General |
SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.34 | 392.61 | 1160.84 | 1.00 | General |
SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 352.19 | 1160.84 | 1.00 | General |
SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 274.58 | 1160.84 | 1.00 | General |
SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 274.71 | 1160.84 | 1.00 | General |
SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 312.26 | 1160.84 | 1.00 | General |
SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 313.05 | 1160.84 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
G SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:12
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 1781.16 | 2137.39 | 0.170 | 0.203 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 32.87 | 0.00565 |
G NW APARTMENT | 1758.61 | 2110.33 | 0.167 | 0.201 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 31.86 | 0.00565 |
OFFICE | 4559.06 | 5470.87 | 0.456 | 0.547 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 09:30:00 | 28.82 | 0.00565 |
G NE APARTMENT | 1295.80 | 1554.96 | 0.123 | 0.148 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 30.98 | 0.00565 |
G N1 APARTMENT | 1010.61 | 1212.73 | 0.096 | 0.115 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 30.85 | 0.00565 |
G N2 APARTMENT | 999.41 | 1199.29 | 0.095 | 0.114 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 30.85 | 0.00565 |
G S1 APARTMENT | 1009.63 | 1211.56 | 0.096 | 0.115 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 35.10 | 0.00565 |
G S2 APARTMENT | 1040.29 | 1248.35 | 0.099 | 0.119 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.93 | 0.00565 |
M SW APARTMENT | 4785.61 | 5742.73 | 0.456 | 0.547 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 32.87 | 0.00565 |
M NW APARTMENT | 4705.28 | 5646.34 | 0.448 | 0.538 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 32.20 | 0.00565 |
M SE APARTMENT | 4060.13 | 4872.16 | 0.387 | 0.464 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 34.93 | 0.00565 |
M NE APARTMENT | 3697.32 | 4436.78 | 0.352 | 0.422 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 31.49 | 0.00565 |
M N1 APARTMENT | 2824.88 | 3389.85 | 0.269 | 0.323 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 30.85 | 0.00565 |
M N2 APARTMENT | 2806.33 | 3367.59 | 0.267 | 0.321 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 31.35 | 0.00565 |
M S1 APARTMENT | 2894.13 | 3472.95 | 0.276 | 0.331 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 35.10 | 0.00565 |
M S2 APARTMENT | 2904.76 | 3485.72 | 0.277 | 0.332 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 35.10 | 0.00565 |
T SW APARTMENT | 3309.42 | 3971.30 | 0.315 | 0.378 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 33.75 | 0.00565 |
T NW APARTMENT | 3200.35 | 3840.42 | 0.305 | 0.366 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 33.21 | 0.00565 |
T SE APARTMENT | 2960.48 | 3552.58 | 0.282 | 0.338 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 35.10 | 0.00565 |
T NE APARTMENT | 2655.69 | 3186.82 | 0.253 | 0.303 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 35.10 | 0.00565 |
T N1 APARTMENT | 2070.41 | 2484.49 | 0.197 | 0.237 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 15:15:00 | 34.90 | 0.00565 |
T N2 APARTMENT | 2071.44 | 2485.73 | 0.197 | 0.237 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 35.10 | 0.00565 |
T S1 APARTMENT | 2354.58 | 2825.49 | 0.224 | 0.269 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 35.10 | 0.00565 |
T S2 APARTMENT | 2360.46 | 2832.56 | 0.225 | 0.270 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 35.10 | 0.00565 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 1206.49 | 1447.79 | 0.042 | 0.051 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -7.90 | 0.00234 |
G NW APARTMENT | 1215.21 | 1458.25 | 0.043 | 0.051 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -7.90 | 0.00234 |
OFFICE | 2553.33 | 3064.00 | 0.086 | 0.103 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -7.90 | 0.00234 |
G NE APARTMENT | 1215.21 | 1458.25 | 0.043 | 0.051 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -7.90 | 0.00234 |
G N1 APARTMENT | 715.12 | 858.14 | 0.025 | 0.030 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -7.90 | 0.00234 |
G N2 APARTMENT | 715.12 | 858.14 | 0.025 | 0.030 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -7.90 | 0.00234 |
G S1 APARTMENT | 708.14 | 849.77 | 0.025 | 0.030 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -7.90 | 0.00234 |
G S2 APARTMENT | 792.06 | 950.47 | 0.028 | 0.033 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -7.90 | 0.00234 |
M SW APARTMENT | 2413.44 | 2896.13 | 0.084 | 0.101 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
M NW APARTMENT | 2434.63 | 2921.55 | 0.085 | 0.102 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
M SE APARTMENT | 2413.44 | 2896.13 | 0.084 | 0.101 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
M NE APARTMENT | 2434.63 | 2921.55 | 0.085 | 0.102 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
M N1 APARTMENT | 1170.98 | 1405.17 | 0.041 | 0.052 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
M N2 APARTMENT | 1170.98 | 1405.17 | 0.041 | 0.052 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
M S1 APARTMENT | 1151.24 | 1381.48 | 0.040 | 0.052 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
M S2 APARTMENT | 1151.24 | 1381.48 | 0.040 | 0.052 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
T SW APARTMENT | 2252.44 | 2702.93 | 0.079 | 0.095 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
T NW APARTMENT | 2264.84 | 2717.81 | 0.079 | 0.095 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
T SE APARTMENT | 2252.44 | 2702.93 | 0.079 | 0.095 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
T NE APARTMENT | 2264.84 | 2717.81 | 0.079 | 0.095 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
T N1 APARTMENT | 1585.00 | 1902.00 | 0.055 | 0.067 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
T N2 APARTMENT | 1585.00 | 1902.00 | 0.055 | 0.067 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
T S1 APARTMENT | 1570.93 | 1885.11 | 0.055 | 0.066 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
T S2 APARTMENT | 1570.93 | 1885.11 | 0.055 | 0.066 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -7.90 | 0.00234 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
SPLIT GSW | 0.20 | 0.20 | 0.05 | 0.05 |
SPLIT GNW | 0.20 | 0.20 | 0.05 | 0.05 |
SPLIT OFFICE | 0.55 | 0.55 | 0.10 | 0.10 |
SPLIT GNE | 0.15 | 0.15 | 0.05 | 0.05 |
SPLIT GN1 | 0.12 | 0.12 | 0.03 | 0.03 |
SPLIT GN2 | 0.11 | 0.11 | 0.03 | 0.03 |
SPLIT GS1 | 0.12 | 0.12 | 0.03 | 0.03 |
SPLIT GS2 | 0.12 | 0.12 | 0.03 | 0.03 |
SPLIT MSW | 0.55 | 0.55 | 0.10 | 0.10 |
SPLIT MNW | 0.54 | 0.54 | 0.10 | 0.10 |
SPLIT MSE | 0.46 | 0.46 | 0.10 | 0.10 |
SPLIT MNE | 0.42 | 0.42 | 0.10 | 0.10 |
SPLIT MN1 | 0.32 | 0.32 | 0.05 | 0.05 |
SPLIT MN2 | 0.32 | 0.32 | 0.05 | 0.05 |
SPLIT MS1 | 0.33 | 0.33 | 0.05 | 0.05 |
SPLIT MS2 | 0.33 | 0.33 | 0.05 | 0.05 |
SPLIT TSW | 0.38 | 0.38 | 0.09 | 0.09 |
SPLIT TNW | 0.37 | 0.37 | 0.10 | 0.10 |
SPLIT TSE | 0.34 | 0.34 | 0.09 | 0.09 |
SPLIT TNE | 0.30 | 0.30 | 0.10 | 0.10 |
SPLIT TN1 | 0.24 | 0.24 | 0.07 | 0.07 |
SPLIT TN2 | 0.24 | 0.24 | 0.07 | 0.07 |
SPLIT TS1 | 0.27 | 0.27 | 0.07 | 0.07 |
SPLIT TS2 | 0.27 | 0.27 | 0.07 | 0.07 |
Report: System Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:12
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 2275.75 | 5709.50 | 216.00 |
G NW APARTMENT | 2721.25 | 5898.25 | 846.00 |
OFFICE | 632.50 | 1382.25 | 2.75 |
G NE APARTMENT | 2710.00 | 5891.00 | 810.75 |
G N1 APARTMENT | 2007.50 | 6056.00 | 409.00 |
G N2 APARTMENT | 2007.00 | 6055.50 | 408.00 |
G S1 APARTMENT | 2002.00 | 5880.75 | 122.25 |
G S2 APARTMENT | 2092.50 | 5810.00 | 98.00 |
M SW APARTMENT | 2966.25 | 3395.25 | 5.50 |
M NW APARTMENT | 2794.00 | 4574.00 | 34.00 |
M SE APARTMENT | 2985.00 | 3373.50 | 4.50 |
M NE APARTMENT | 2809.50 | 4534.00 | 34.25 |
M N1 APARTMENT | 2571.00 | 4626.75 | 12.50 |
M N2 APARTMENT | 2573.00 | 4629.75 | 12.50 |
M S1 APARTMENT | 2810.75 | 3035.00 | 10.00 |
M S2 APARTMENT | 2813.75 | 3037.50 | 9.75 |
T SW APARTMENT | 3468.75 | 4152.50 | 551.25 |
T NW APARTMENT | 3887.50 | 4944.75 | 1261.50 |
T SE APARTMENT | 3476.00 | 4101.75 | 566.25 |
T NE APARTMENT | 3869.75 | 4963.50 | 1246.75 |
T N1 APARTMENT | 3428.75 | 5054.25 | 924.00 |
T N2 APARTMENT | 3435.50 | 5051.00 | 928.25 |
T S1 APARTMENT | 2992.00 | 4116.50 | 259.75 |
T S2 APARTMENT | 2995.75 | 4108.00 | 261.75 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 4926.00 | 6139.50 | 1544.75 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 5.25 | 0.25 | 5.25 | 0.25 |
G NW APARTMENT | 2.25 | 0.00 | 2.25 | 0.00 |
OFFICE | 1.25 | 14.50 | 0.00 | 0.00 |
G NE APARTMENT | 3.25 | 0.00 | 3.25 | 0.00 |
G N1 APARTMENT | 8.75 | 0.00 | 8.75 | 0.00 |
G N2 APARTMENT | 8.75 | 0.00 | 8.75 | 0.00 |
G S1 APARTMENT | 2.25 | 0.25 | 2.25 | 0.25 |
G S2 APARTMENT | 2.25 | 0.00 | 2.25 | 0.00 |
M SW APARTMENT | 0.25 | 0.00 | 0.25 | 0.00 |
M NW APARTMENT | 0.75 | 0.00 | 0.75 | 0.00 |
M SE APARTMENT | 2.00 | 0.00 | 2.00 | 0.00 |
M NE APARTMENT | 0.25 | 0.00 | 0.25 | 0.00 |
M N1 APARTMENT | 0.50 | 0.00 | 0.50 | 0.00 |
M N2 APARTMENT | 1.00 | 0.00 | 1.00 | 0.00 |
M S1 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
M S2 APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T SW APARTMENT | 0.00 | 0.25 | 0.00 | 0.25 |
T NW APARTMENT | 0.00 | 1.25 | 0.00 | 1.25 |
T SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 0.00 | 0.25 | 0.00 | 0.25 |
T N1 APARTMENT | 0.25 | 0.00 | 0.25 | 0.00 |
T N2 APARTMENT | 0.25 | 0.00 | 0.25 | 0.00 |
T S1 APARTMENT | 0.75 | 0.00 | 0.75 | 0.00 |
T S2 APARTMENT | 0.25 | 0.00 | 0.25 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 37.00 | 16.75 | 35.75 | 2.25 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:12
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.364 | 0.174 | 0.000 | 0.081 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.174 | 0.000 | 0.077 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.517 | 0.180 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.174 | 0.000 | 0.077 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.105 | 0.000 | 0.076 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.351 | 0.105 | 0.000 | 0.076 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.105 | 0.000 | 0.080 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.105 | 0.000 | 0.080 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.250 | 0.000 | 0.100 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.250 | 0.000 | 0.096 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.250 | 0.000 | 0.100 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.250 | 0.000 | 0.096 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.151 | 0.000 | 0.095 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.151 | 0.000 | 0.095 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.151 | 0.000 | 0.100 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.151 | 0.000 | 0.100 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.331 | 0.000 | 0.122 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.331 | 0.000 | 0.116 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.331 | 0.000 | 0.122 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.331 | 0.000 | 0.116 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.199 | 0.000 | 0.115 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.199 | 0.000 | 0.115 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.200 | 0.000 | 0.122 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.200 | 0.000 | 0.122 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.502 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 1.370 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 1.367 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 1.370 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 1.367 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.367 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.367 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.373 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.373 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:12
Surfaces by ClassTotal | Outdoors | |
Wall | 126 | 42 |
Floor | 27 | 9 |
Roof | 27 | 9 |
Internal Mass | 24 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 39 | 39 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 24 |
Conditioned Zones | 24 |
Unconditioned Zones | 3 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 1385 |
Defaulted Fields | 439 |
Fields with Defaults | 3704 |
Autosized Fields | 336 |
Autosizable Fields | 454 |
Autocalculated Fields | 247 |
Autocalculatable Fields | 424 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2015-09-09 18:47:12
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 1472.01 | 21513.59 | 01-JAN-03:15 | 82340.84 | 21-JUL-17:30 |
Electricity:Building | 636.11 | 10559.61 | 01-JAN-03:15 | 31610.87 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity | 118.46 | 2466.75 | 01-JAN-00:15 | 5482.59 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 96.36 | 2205.67 | 01-JAN-00:15 | 4426.44 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 35.93 | 610.39 | 01-JAN-00:15 | 2669.36 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 26.45 | 416.15 | 01-JAN-00:15 | 2080.74 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M SW APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:T SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 144.16 | 1427.03 | 01-JAN-00:15 | 8651.76 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 14.58 | 462.39 | 01-JAN-00:15 | 462.39 | 01-JAN-00:15 |
Electricity:Zone:M CORRIDOR | 29.16 | 924.77 | 01-JAN-00:15 | 924.77 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 29.16 | 924.77 | 01-JAN-00:15 | 924.77 | 01-JAN-00:15 |
Electricity:Zone:T CORRIDOR | 14.58 | 462.39 | 01-JAN-00:15 | 462.39 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 14.58 | 462.39 | 01-JAN-00:15 | 462.39 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 22.11 | 261.08 | 01-JAN-00:15 | 1411.40 | 02-JAN-16:15 |
InteriorEquipment:Electricity | 517.65 | 8092.87 | 01-JAN-03:15 | 26730.99 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 517.65 | 8092.87 | 01-JAN-03:15 | 26730.99 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 9.48 | 194.25 | 01-JAN-00:15 | 588.62 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G CORRIDOR | 129.57 | 964.65 | 01-JAN-00:15 | 8189.37 | 01-JAN-07:15 |
Electricity:Plant | 383.84 | 0.00 | 01-JAN-00:15 | 32341.56 | 01-JAN-08:30 |
WaterSystems:Electricity | 383.84 | 0.00 | 01-JAN-00:15 | 32341.56 | 01-JAN-08:30 |
Water Heater:WaterSystems:Electricity | 383.84 | 0.00 | 01-JAN-00:15 | 32341.56 | 01-JAN-08:30 |
Fans:Electricity | 264.93 | 8400.98 | 03-JAN-08:30 | 8400.98 | 01-JAN-00:15 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 1472.01 | 21513.59 | 01-JAN-03:15 | 82340.84 | 21-JUL-17:30 |
ElectricityPurchased:Plant | 1472.01 | 21513.59 | 01-JAN-03:15 | 82340.84 | 21-JUL-17:30 |
Cogeneration:ElectricityPurchased | 1472.01 | 21513.59 | 01-JAN-03:15 | 82340.84 | 21-JUL-17:30 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 1472.01 | 21513.59 | 01-JAN-03:15 | 82340.84 | 21-JUL-17:30 |
ElectricityNet:Plant | 1472.01 | 21513.59 | 01-JAN-03:15 | 82340.84 | 21-JUL-17:30 |
Cogeneration:ElectricityNet | 1472.01 | 21513.59 | 01-JAN-03:15 | 82340.84 | 21-JUL-17:30 |
ExteriorLights:Electricity | 40.11 | 0.00 | 01-JAN-07:30 | 2553.00 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 40.11 | 0.00 | 01-JAN-07:30 | 2553.00 | 01-JAN-00:15 |
Electricity:HVAC | 411.94 | 8400.98 | 14-JAN-08:30 | 32888.06 | 29-JUN-15:00 |
General:Fans:Electricity | 264.93 | 8400.98 | 03-JAN-08:30 | 8400.98 | 01-JAN-00:15 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:Electricity | 147.01 | 0.00 | 01-JAN-00:15 | 24487.08 | 29-JUN-15:00 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 127.18 | 0.00 | 01-JAN-13:30 | 60925.70 | 18-JAN-01:15 |
Gas:HVAC | 127.18 | 0.00 | 01-JAN-13:30 | 60925.70 | 18-JAN-01:15 |
Heating:Gas | 127.18 | 0.00 | 01-JAN-13:30 | 60925.70 | 18-JAN-01:15 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 1239.99 | 2071.80 | 21-MAY-06:00 | 151467.70 | 29-JUN-15:15 |
EnergyTransfer:Building | 567.32 | 2071.80 | 21-MAY-06:00 | 66091.79 | 29-JUN-15:15 |
EnergyTransfer:Zone:G SW APARTMENT | 11.46 | 0.00 | 18-MAY-02:45 | 2122.03 | 04-JUL-17:00 |
Heating:EnergyTransfer | 65.17 | 0.00 | 03-JAN-20:15 | 39688.69 | 14-DEC-04:00 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 1.90 | 0.00 | 01-JAN-08:30 | 1297.17 | 14-DEC-04:00 |
Cooling:EnergyTransfer | 502.15 | 0.00 | 17-JAN-07:15 | 66091.79 | 29-JUN-15:15 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 9.56 | 0.00 | 01-JAN-00:15 | 2122.03 | 04-JUL-17:00 |
EnergyTransfer:Zone:G NW APARTMENT | 10.89 | 0.00 | 30-APR-03:15 | 2150.78 | 04-JUL-17:15 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 3.97 | 0.00 | 01-JAN-16:30 | 1569.43 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 6.92 | 0.00 | 01-JAN-00:15 | 2150.78 | 04-JUL-17:15 |
EnergyTransfer:Zone:OFFICE | 27.40 | 0.02 | 16-NOV-19:30 | 4559.25 | 20-AUG-11:00 |
Heating:EnergyTransfer:Zone:OFFICE | 4.32 | 0.00 | 01-JAN-00:15 | 1674.69 | 17-JAN-07:15 |
Cooling:EnergyTransfer:Zone:OFFICE | 23.08 | 0.00 | 01-JAN-11:45 | 4559.25 | 20-AUG-11:00 |
EnergyTransfer:Zone:G NE APARTMENT | 11.09 | 0.01 | 14-JAN-16:30 | 1583.85 | 14-DEC-04:00 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 3.69 | 0.00 | 01-JAN-10:15 | 1583.85 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 7.40 | 0.00 | 01-JAN-00:15 | 1541.54 | 04-JUL-17:15 |
EnergyTransfer:Zone:G N1 APARTMENT | 7.43 | 0.01 | 22-MAY-02:30 | 1167.74 | 04-JUL-17:30 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 1.72 | 0.00 | 01-JAN-11:30 | 899.62 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 5.71 | 0.00 | 01-JAN-00:15 | 1167.74 | 04-JUL-17:30 |
EnergyTransfer:Zone:G N2 APARTMENT | 7.45 | 0.00 | 02-OCT-01:15 | 1155.28 | 04-JUL-17:30 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 1.72 | 0.00 | 01-JAN-11:15 | 900.94 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 5.73 | 0.00 | 01-JAN-00:15 | 1155.28 | 04-JUL-17:30 |
EnergyTransfer:Zone:G S1 APARTMENT | 9.35 | 0.01 | 20-APR-15:45 | 1400.66 | 21-SEP-13:30 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 0.49 | 0.00 | 01-JAN-00:15 | 691.07 | 18-JAN-01:15 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 8.86 | 0.00 | 01-JAN-02:00 | 1400.66 | 21-SEP-13:30 |
EnergyTransfer:Zone:G S2 APARTMENT | 9.84 | 0.01 | 10-MAY-09:30 | 1472.41 | 03-SEP-13:30 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 0.51 | 0.00 | 01-JAN-00:15 | 716.16 | 18-JAN-01:15 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 9.33 | 0.00 | 01-JAN-02:15 | 1472.41 | 03-SEP-13:30 |
EnergyTransfer:Zone:M SW APARTMENT | 44.53 | 0.17 | 24-OCT-09:00 | 5616.29 | 04-JUL-17:00 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 0.45 | 0.00 | 01-JAN-00:15 | 2415.69 | 18-JAN-01:15 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 44.08 | 0.00 | 11-JAN-05:15 | 5616.29 | 04-JUL-17:00 |
EnergyTransfer:Zone:M NW APARTMENT | 32.81 | 0.01 | 04-MAR-14:45 | 5629.01 | 04-JUL-17:15 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 3.07 | 0.00 | 01-JAN-08:30 | 3525.77 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 29.74 | 0.00 | 01-JAN-00:15 | 5629.01 | 04-JUL-17:15 |
EnergyTransfer:Zone:M SE APARTMENT | 46.43 | 0.00 | 02-JUN-03:30 | 4784.89 | 03-SEP-13:30 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 0.49 | 0.00 | 01-JAN-00:15 | 2443.15 | 18-JAN-01:15 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 45.94 | 0.00 | 11-JAN-05:00 | 4784.89 | 03-SEP-13:30 |
EnergyTransfer:Zone:M NE APARTMENT | 34.85 | 0.08 | 10-FEB-15:00 | 4339.00 | 04-JUL-17:00 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 3.06 | 0.00 | 01-JAN-07:45 | 3597.51 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 31.79 | 0.00 | 01-JAN-00:15 | 4339.00 | 04-JUL-17:00 |
EnergyTransfer:Zone:M N1 APARTMENT | 27.95 | 0.14 | 15-FEB-15:30 | 3210.06 | 04-JUL-17:15 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 0.55 | 0.00 | 01-JAN-00:15 | 1800.97 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 27.40 | 0.00 | 01-JAN-02:45 | 3210.06 | 04-JUL-17:15 |
EnergyTransfer:Zone:M N2 APARTMENT | 27.99 | 0.06 | 31-OCT-11:45 | 3192.03 | 04-JUL-17:15 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 0.56 | 0.00 | 01-JAN-00:15 | 1810.30 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 27.44 | 0.00 | 01-JAN-02:45 | 3192.03 | 04-JUL-17:15 |
EnergyTransfer:Zone:M S1 APARTMENT | 43.28 | 0.13 | 03-MAY-12:00 | 4137.77 | 11-OCT-12:45 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 0.03 | 0.00 | 01-JAN-00:15 | 974.68 | 18-JAN-01:15 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 43.25 | 0.00 | 17-JAN-02:00 | 4137.77 | 11-OCT-12:45 |
EnergyTransfer:Zone:M S2 APARTMENT | 43.31 | 0.38 | 03-MAY-17:15 | 4144.40 | 11-OCT-12:45 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 0.03 | 0.00 | 01-JAN-00:15 | 978.47 | 18-JAN-01:15 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 43.28 | 0.00 | 17-JAN-02:00 | 4144.40 | 11-OCT-12:45 |
EnergyTransfer:Zone:T SW APARTMENT | 25.45 | 0.02 | 22-FEB-18:45 | 3812.88 | 04-JUL-17:00 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 5.06 | 0.00 | 01-JAN-08:45 | 2645.50 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 20.38 | 0.00 | 01-JAN-00:15 | 3812.88 | 04-JUL-17:00 |
EnergyTransfer:Zone:T NW APARTMENT | 23.17 | 0.00 | 06-FEB-15:30 | 3820.00 | 04-JUL-17:00 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 8.19 | 0.00 | 03-JAN-20:15 | 3061.44 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 14.98 | 0.00 | 01-JAN-00:15 | 3820.00 | 04-JUL-17:00 |
EnergyTransfer:Zone:T SE APARTMENT | 25.67 | 0.00 | 14-NOV-23:15 | 3370.23 | 03-SEP-13:30 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 4.82 | 0.00 | 01-JAN-08:15 | 2669.02 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 20.84 | 0.00 | 01-JAN-00:15 | 3370.23 | 03-SEP-13:30 |
EnergyTransfer:Zone:T NE APARTMENT | 23.11 | 0.00 | 09-OCT-03:45 | 3124.33 | 29-JUN-15:00 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 7.72 | 0.00 | 01-JAN-10:15 | 3094.59 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 15.39 | 0.00 | 01-JAN-00:15 | 3124.33 | 29-JUN-15:00 |
EnergyTransfer:Zone:T N1 APARTMENT | 16.64 | 0.01 | 11-FEB-14:00 | 2411.14 | 29-JUN-15:15 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 4.35 | 0.00 | 01-JAN-10:45 | 1926.55 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 12.29 | 0.00 | 01-JAN-00:15 | 2411.14 | 29-JUN-15:15 |
EnergyTransfer:Zone:T N2 APARTMENT | 16.69 | 0.01 | 06-MAR-13:15 | 2406.82 | 29-JUN-15:15 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 4.37 | 0.00 | 01-JAN-10:45 | 1929.59 | 14-DEC-04:00 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 12.32 | 0.00 | 01-JAN-00:15 | 2406.82 | 29-JUN-15:15 |
EnergyTransfer:Zone:T S1 APARTMENT | 20.24 | 0.00 | 04-MAY-11:45 | 2821.24 | 03-SEP-13:30 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 2.04 | 0.00 | 01-JAN-00:15 | 1544.79 | 17-JAN-04:00 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 18.20 | 0.00 | 01-JAN-01:30 | 2821.24 | 03-SEP-13:30 |
EnergyTransfer:Zone:T S2 APARTMENT | 20.30 | 0.01 | 28-JAN-11:15 | 2829.37 | 03-SEP-13:30 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 2.05 | 0.00 | 01-JAN-00:15 | 1545.50 | 17-JAN-04:00 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 18.25 | 0.00 | 01-JAN-01:30 | 2829.37 | 03-SEP-13:30 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:HVAC | 672.67 | 0.00 | 15-APR-09:45 | 85428.94 | 29-JUN-15:00 |
HeatingCoils:EnergyTransfer | 101.74 | 0.00 | 01-JAN-13:30 | 48740.56 | 18-JAN-01:15 |
CoolingCoils:EnergyTransfer | 570.92 | 0.00 | 01-JAN-00:15 | 85428.94 | 29-JUN-15:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:12
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 1.902 | -9.558 | 0.000 | 0.000 | 3.782 | 1.087 | 12.213 | 18.728 | 0.000 | 0.330 | 0.000 | 0.000 | -6.359 | 0.000 | -4.605 | -17.519 |
G NW APARTMENT | 3.970 | -6.916 | 0.000 | 0.000 | 3.819 | 1.087 | 12.213 | 9.451 | 0.000 | 0.328 | 0.000 | 0.000 | -6.479 | 0.000 | -4.433 | -13.040 |
OFFICE | 4.316 | -23.082 | 0.000 | 0.000 | 0.518 | 26.452 | 9.482 | 18.946 | 0.000 | 0.190 | 0.001 | 0.000 | -6.622 | 0.000 | -4.295 | -25.905 |
G NE APARTMENT | 3.690 | -7.399 | 0.000 | 0.000 | 3.831 | 1.087 | 12.213 | 9.829 | 0.000 | 0.328 | 0.000 | 0.000 | -6.176 | 0.000 | -4.410 | -12.991 |
G N1 APARTMENT | 1.720 | -5.711 | 0.000 | 0.000 | 3.835 | 1.087 | 12.213 | 3.151 | 0.000 | 0.211 | 0.000 | 0.000 | -3.975 | 0.000 | -2.872 | -9.658 |
G N2 APARTMENT | 1.721 | -5.728 | 0.000 | 0.000 | 3.835 | 1.087 | 12.213 | 3.150 | 0.000 | 0.211 | 0.000 | 0.000 | -3.974 | 0.000 | -2.872 | -9.643 |
G S1 APARTMENT | 0.489 | -8.860 | 0.000 | 0.000 | 3.788 | 1.087 | 12.213 | 12.523 | 0.000 | 0.212 | 0.000 | 0.000 | -3.841 | 0.000 | -3.038 | -14.571 |
G S2 APARTMENT | 0.513 | -9.329 | 0.000 | 0.000 | 3.784 | 1.087 | 12.213 | 12.513 | 0.000 | 0.212 | 0.000 | 0.000 | -3.851 | 0.000 | -3.049 | -14.093 |
M SW APARTMENT | 0.450 | -44.080 | 0.000 | 0.000 | 3.628 | 1.087 | 12.213 | 18.187 | 0.000 | 0.468 | 22.021 | 0.000 | -7.091 | 0.000 | -6.884 | 0.000 |
M NW APARTMENT | 3.067 | -29.738 | 0.000 | 0.000 | 3.716 | 1.087 | 12.213 | 9.040 | 0.000 | 0.465 | 13.845 | 0.000 | -7.089 | 0.000 | -6.605 | -0.001 |
M SE APARTMENT | 0.491 | -45.935 | 0.000 | 0.000 | 3.638 | 1.087 | 12.213 | 18.689 | 0.000 | 0.468 | 23.126 | 0.000 | -6.906 | 0.000 | -6.871 | 0.000 |
M NE APARTMENT | 3.058 | -31.788 | 0.000 | 0.000 | 3.729 | 1.087 | 12.213 | 9.397 | 0.000 | 0.465 | 15.160 | 0.000 | -6.746 | 0.000 | -6.575 | -0.000 |
M N1 APARTMENT | 0.552 | -27.396 | 0.000 | 0.000 | 3.709 | 1.087 | 12.213 | 2.902 | 0.000 | 0.295 | 15.399 | 0.000 | -4.420 | 0.000 | -4.341 | 0.000 |
M N2 APARTMENT | 0.556 | -27.437 | 0.000 | 0.000 | 3.710 | 1.087 | 12.213 | 2.901 | 0.000 | 0.295 | 15.431 | 0.000 | -4.417 | 0.000 | -4.339 | 0.000 |
M S1 APARTMENT | 0.031 | -43.245 | 0.000 | 0.000 | 3.594 | 1.087 | 12.213 | 12.168 | 0.000 | 0.299 | 22.757 | 0.000 | -4.332 | 0.000 | -4.571 | 0.000 |
M S2 APARTMENT | 0.030 | -43.283 | 0.000 | 0.000 | 3.594 | 1.087 | 12.213 | 12.168 | 0.000 | 0.299 | 22.795 | 0.000 | -4.331 | 0.000 | -4.571 | 0.000 |
T SW APARTMENT | 5.064 | -20.381 | 0.000 | 0.000 | 3.722 | 1.087 | 12.213 | 18.058 | 0.000 | 0.625 | 0.000 | 0.000 | -6.624 | 0.000 | -8.663 | -5.101 |
T NW APARTMENT | 8.193 | -14.980 | 0.000 | 0.000 | 3.765 | 1.087 | 12.213 | 8.927 | 0.000 | 0.619 | 0.000 | 0.000 | -6.707 | 0.000 | -8.414 | -4.703 |
T SE APARTMENT | 4.824 | -20.843 | 0.000 | 0.000 | 3.729 | 1.087 | 12.213 | 18.566 | 0.000 | 0.625 | 0.000 | 0.000 | -6.464 | 0.000 | -8.663 | -5.073 |
T NE APARTMENT | 7.724 | -15.390 | 0.000 | 0.000 | 3.777 | 1.087 | 12.213 | 9.319 | 0.000 | 0.619 | 0.000 | 0.000 | -6.413 | 0.000 | -8.389 | -4.545 |
T N1 APARTMENT | 4.350 | -12.291 | 0.000 | 0.000 | 3.769 | 1.087 | 12.213 | 2.882 | 0.000 | 0.397 | 0.000 | 0.000 | -4.147 | 0.000 | -5.448 | -2.812 |
T N2 APARTMENT | 4.367 | -12.322 | 0.000 | 0.000 | 3.769 | 1.087 | 12.213 | 2.879 | 0.000 | 0.397 | 0.000 | 0.000 | -4.144 | 0.000 | -5.450 | -2.796 |
T S1 APARTMENT | 2.042 | -18.199 | 0.000 | 0.000 | 3.708 | 1.087 | 12.213 | 12.115 | 0.000 | 0.403 | 0.000 | 0.000 | -4.042 | 0.000 | -5.675 | -3.650 |
T S2 APARTMENT | 2.051 | -18.251 | 0.000 | 0.000 | 3.708 | 1.087 | 12.213 | 12.112 | 0.000 | 0.403 | 0.000 | 0.000 | -4.040 | 0.000 | -5.676 | -3.607 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 14.582 | 0.000 | 0.178 | 0.000 | 0.039 | 0.000 | 0.000 | -0.742 | 0.000 | -1.436 | -12.621 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 14.582 | 6.479 | 0.628 | 0.000 | 1.168 | 0.607 | 0.000 | -1.906 | 0.000 | -21.557 | -0.000 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 14.582 | 0.000 | 0.180 | 0.000 | 0.036 | 0.000 | 0.000 | -0.827 | 0.000 | -1.195 | -12.776 |
Total Facility | 65.172 | -502.143 | 0.000 | 0.000 | 86.457 | 95.189 | 296.854 | 259.585 | 0.000 | 10.409 | 151.143 | 0.000 | -132.662 | 0.000 | -154.897 | -175.107 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 04-JUL-17:00 | 0.00 | -2121.70 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2096.96 | 0.00 | 316.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1029.89 |
G NW APARTMENT | 04-JUL-17:05 | 0.00 | -2151.85 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 2256.54 | 0.00 | 284.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1206.70 |
OFFICE | 23-JUL-06:01 | 0.00 | -8021.00 | 0.00 | 0.00 | 0.00 | 416.15 | 294.31 | 962.59 | 0.00 | 0.00 | 6361.98 | 0.00 | 0.00 | 0.00 | -14.02 | 0.00 |
G NE APARTMENT | 04-JUL-17:15 | 0.00 | -1542.49 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 748.06 | 0.00 | 284.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -307.59 |
G N1 APARTMENT | 04-JUL-17:20 | 0.00 | -1168.03 | 0.00 | 0.00 | 141.80 | 87.56 | 588.62 | 583.80 | 0.00 | 152.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -386.56 |
G N2 APARTMENT | 04-JUL-17:20 | 0.00 | -1155.63 | 0.00 | 0.00 | 141.80 | 87.56 | 588.62 | 583.99 | 0.00 | 152.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -399.14 |
G S1 APARTMENT | 21-SEP-13:30 | 0.00 | -1400.66 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1936.97 | 0.00 | 22.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -995.50 |
G S2 APARTMENT | 03-SEP-13:30 | 0.00 | -1472.41 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1824.33 | 0.00 | 51.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -839.30 |
M SW APARTMENT | 04-JUL-17:00 | 0.00 | -5615.56 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2084.50 | 0.00 | 453.92 | 2338.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NW APARTMENT | 04-JUL-17:05 | 0.00 | -5630.84 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 2241.79 | 0.00 | 407.44 | 2163.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M SE APARTMENT | 03-SEP-13:30 | 0.00 | -4784.86 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 2177.91 | 0.00 | 121.32 | 2049.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NE APARTMENT | 04-JUL-17:00 | 0.00 | -4338.53 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 731.57 | 0.00 | 453.91 | 2414.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N1 APARTMENT | 04-JUL-17:08 | 0.00 | -3211.30 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 541.76 | 0.00 | 245.76 | 1605.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 04-JUL-17:05 | 0.00 | -3194.73 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 541.87 | 0.00 | 245.76 | 1589.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | 11-OCT-12:45 | 0.00 | -4135.31 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2063.53 | 0.00 | 297.48 | 1332.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S2 APARTMENT | 11-OCT-12:45 | 0.00 | -4141.94 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2063.49 | 0.00 | 297.48 | 1338.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SW APARTMENT | 04-JUL-17:00 | 0.00 | -3812.44 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2047.95 | 0.00 | 598.34 | 427.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 04-JUL-17:00 | 0.00 | -3819.57 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2214.06 | 0.00 | 598.34 | 268.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SE APARTMENT | 03-SEP-13:30 | 0.00 | -3370.21 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 2138.29 | 0.00 | 159.62 | 635.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 29-JUN-15:00 | 0.00 | -3123.10 | 0.00 | 0.00 | 40.75 | 22.70 | 400.26 | 1029.60 | 0.00 | 520.54 | 1109.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 29-JUN-15:15 | 0.00 | -2410.47 | 0.00 | 0.00 | 48.90 | 45.40 | 470.90 | 604.59 | 0.00 | 290.45 | 950.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 29-JUN-15:15 | 0.00 | -2406.16 | 0.00 | 0.00 | 48.90 | 45.40 | 470.90 | 604.63 | 0.00 | 290.45 | 945.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 03-SEP-13:30 | 0.00 | -2821.22 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1787.12 | 0.00 | 96.28 | 501.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S2 APARTMENT | 03-SEP-13:30 | 0.00 | -2829.35 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1786.99 | 0.00 | 96.28 | 509.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 29-JUN-15:15 | 0.00 | -66073.49 | 0.00 | 0.00 | 1192.02 | 4512.09 | 11708.34 | 23558.88 | 0.00 | 7858.21 | 17243.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 14-DEC-04:00 | 1296.93 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 100.85 | 0.00 | -641.64 | 0.00 | -1175.98 | 0.00 |
G NW APARTMENT | 14-DEC-04:00 | 1569.14 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -641.17 | 0.00 | -1175.98 | -171.83 |
OFFICE | 11-JAN-07:01 | 3784.87 | 0.00 | 0.00 | 0.00 | 0.00 | 416.15 | 294.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -543.78 | 0.00 | -475.41 | -3476.13 |
G NE APARTMENT | 14-DEC-04:00 | 1583.54 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -632.12 | 0.00 | -1175.98 | -195.28 |
G N1 APARTMENT | 16-FEB-07:01 | 987.44 | 0.00 | 0.00 | 0.00 | 163.19 | 42.16 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -290.09 | 0.00 | -89.19 | -1196.11 |
G N2 APARTMENT | 07-DEC-17:01 | 1317.20 | 0.00 | 0.00 | 0.00 | 99.80 | 64.86 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -260.75 | 0.00 | -87.70 | -1722.03 |
G S1 APARTMENT | 19-FEB-07:01 | 1147.77 | 0.00 | 0.00 | 0.00 | 161.41 | 42.16 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -44.70 | 0.00 | -132.44 | -1556.80 |
G S2 APARTMENT | 28-NOV-07:01 | 1210.14 | 0.00 | 0.00 | 0.00 | 161.42 | 42.16 | 382.60 | 501.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -168.98 | -2128.57 |
M SW APARTMENT | 18-JAN-01:15 | 2415.46 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 241.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -660.57 | 0.00 | -1115.07 | -1077.32 |
M NW APARTMENT | 14-DEC-04:00 | 3525.08 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -665.61 | 0.00 | -1691.45 | -1587.86 |
M SE APARTMENT | 18-JAN-01:15 | 2442.91 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 241.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -670.21 | 0.00 | -1115.07 | -1095.11 |
M NE APARTMENT | 14-DEC-04:00 | 3596.75 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -653.79 | 0.00 | -1691.45 | -1671.35 |
M N1 APARTMENT | 14-DEC-04:00 | 1800.65 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -404.96 | 0.00 | -1020.24 | -795.28 |
M N2 APARTMENT | 09-JAN-07:01 | 2079.42 | 0.00 | 0.00 | 0.00 | 161.41 | 42.16 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -406.04 | 0.00 | -243.05 | -2016.50 |
M S1 APARTMENT | 18-JAN-01:15 | 974.59 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 241.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -409.55 | 0.00 | -672.58 | -329.95 |
M S2 APARTMENT | 18-JAN-01:15 | 978.39 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 241.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -409.51 | 0.00 | -672.58 | -333.79 |
T SW APARTMENT | 14-DEC-04:00 | 2644.97 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -644.65 | 0.00 | -2241.15 | -179.01 |
T NW APARTMENT | 14-DEC-04:00 | 3060.83 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -642.59 | 0.00 | -2241.15 | -596.93 |
T SE APARTMENT | 14-DEC-04:00 | 2668.47 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -633.75 | 0.00 | -2241.15 | -213.41 |
T NE APARTMENT | 14-DEC-04:00 | 3093.94 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -632.01 | 0.00 | -2241.15 | -640.61 |
T N1 APARTMENT | 14-DEC-04:00 | 1926.19 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -389.49 | 0.00 | -1351.85 | -604.69 |
T N2 APARTMENT | 14-DEC-04:00 | 1929.24 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -389.43 | 0.00 | -1351.85 | -607.80 |
T S1 APARTMENT | 17-JAN-04:00 | 1544.77 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -405.38 | 0.00 | -898.58 | -660.65 |
T S2 APARTMENT | 17-JAN-04:00 | 1545.48 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 223.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -405.37 | 0.00 | -898.58 | -661.37 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 14-DEC-04:00 | 38087.63 | 0.00 | 0.00 | 0.00 | 4357.79 | 1952.47 | 5387.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -12790.80 | 0.00 | -33546.24 | -3447.90 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:12
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:12
Sec1.1A-General InformationData | |
Weather File | Albuquerque Intl Arpt Isis NM USA TMY3 WMO#=723650 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 3134.61 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.32 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 3134.61 | 2823.98 | 310.64 |
Data | |
Number of hours heating loads not met | 35.75 |
Number of hours cooling loads not met | 2.25 |
Number of hours not met | 38.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 118.46 | 4979.95 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 40.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 0.00 | 0.00 | 127.18 | 60925.70 | 0.00 | 0.00 |
Space Cooling | 147.01 | 22755.18 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 264.93 | 8400.98 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 383.84 | 19573.81 | 0.00 | 0.00 | 0.00 | 0.00 |
Receptacle Equipment | 517.65 | 26630.92 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 1472.01 | 127.18 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 517.65 | 1472.01 |
Natural Gas | 0.00 | 127.18 |
Additional | 0.00 | 0.00 |
Total | 517.65 | 1599.19 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 37.79 |
Space Heating | 0.00 |
Space Cooling | 46.90 |
Fans-Interior | 84.52 |
Service Water Heating | 122.45 |
Receptacle Equipment | 165.14 |
Miscellaneous | 12.80 |
Subtotal | 469.60 |
Natural Gas [MJ/m2] | |
Space Heating | 40.57 |
Service Water Heating | 0.00 |
Miscellaneous | 0.00 |
Subtotal | 40.57 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 7.41 |
Space Heating | 7.95 |
Space Cooling | 9.19 |
Fans-Interior | 16.57 |
Service Water Heating | 24.00 |
Receptacle Equipment | 32.37 |
Miscellaneous | 2.51 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:12
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.203491 |
G NW APARTMENT DIRECT AIR | 0.200917 |
OFFICE DIRECT AIR | 0.547152 |
G NE APARTMENT DIRECT AIR | 0.148040 |
G N1 APARTMENT DIRECT AIR | 0.115461 |
G N2 APARTMENT DIRECT AIR | 0.114182 |
G S1 APARTMENT DIRECT AIR | 0.115348 |
G S2 APARTMENT DIRECT AIR | 0.118851 |
M SW APARTMENT DIRECT AIR | 0.546733 |
M NW APARTMENT DIRECT AIR | 0.537562 |
M SE APARTMENT DIRECT AIR | 0.463847 |
M NE APARTMENT DIRECT AIR | 0.422397 |
M N1 APARTMENT DIRECT AIR | 0.322737 |
M N2 APARTMENT DIRECT AIR | 0.320618 |
M S1 APARTMENT DIRECT AIR | 0.330645 |
M S2 APARTMENT DIRECT AIR | 0.331859 |
T SW APARTMENT DIRECT AIR | 0.378074 |
T NW APARTMENT DIRECT AIR | 0.365614 |
T SE APARTMENT DIRECT AIR | 0.338211 |
T NE APARTMENT DIRECT AIR | 0.303390 |
T N1 APARTMENT DIRECT AIR | 0.236535 |
T N2 APARTMENT DIRECT AIR | 0.236652 |
T S1 APARTMENT DIRECT AIR | 0.268999 |
T S2 APARTMENT DIRECT AIR | 0.269671 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW MAIN BRANCH | 0.203491 |
SPLIT GNW MAIN BRANCH | 0.200917 |
SPLIT OFFICE MAIN BRANCH | 0.547152 |
SPLIT GNE MAIN BRANCH | 0.148040 |
SPLIT GN1 MAIN BRANCH | 0.115461 |
SPLIT GN2 MAIN BRANCH | 0.114182 |
SPLIT GS1 MAIN BRANCH | 0.115348 |
SPLIT GS2 MAIN BRANCH | 0.118851 |
SPLIT MSW MAIN BRANCH | 0.546733 |
SPLIT MNW MAIN BRANCH | 0.537562 |
SPLIT MSE MAIN BRANCH | 0.463847 |
SPLIT MNE MAIN BRANCH | 0.422397 |
SPLIT MN1 MAIN BRANCH | 0.322737 |
SPLIT MN2 MAIN BRANCH | 0.320618 |
SPLIT MS1 MAIN BRANCH | 0.330645 |
SPLIT MS2 MAIN BRANCH | 0.331859 |
SPLIT TSW MAIN BRANCH | 0.378074 |
SPLIT TNW MAIN BRANCH | 0.365614 |
SPLIT TSE MAIN BRANCH | 0.338211 |
SPLIT TNE MAIN BRANCH | 0.303390 |
SPLIT TN1 MAIN BRANCH | 0.236535 |
SPLIT TN2 MAIN BRANCH | 0.236652 |
SPLIT TS1 MAIN BRANCH | 0.268999 |
SPLIT TS2 MAIN BRANCH | 0.269671 |
Design Supply Air Flow Rate [m3/s] | |
SPLIT GSW | 0.203491 |
SPLIT GNW | 0.200917 |
SPLIT OFFICE | 0.547152 |
SPLIT GNE | 0.148040 |
SPLIT GN1 | 0.115461 |
SPLIT GN2 | 0.114182 |
SPLIT GS1 | 0.115348 |
SPLIT GS2 | 0.118851 |
SPLIT MSW | 0.546733 |
SPLIT MNW | 0.537562 |
SPLIT MSE | 0.463847 |
SPLIT MNE | 0.422397 |
SPLIT MN1 | 0.322737 |
SPLIT MN2 | 0.320618 |
SPLIT MS1 | 0.330645 |
SPLIT MS2 | 0.331859 |
SPLIT TSW | 0.378074 |
SPLIT TNW | 0.365614 |
SPLIT TSE | 0.338211 |
SPLIT TNE | 0.303390 |
SPLIT TN1 | 0.236535 |
SPLIT TN2 | 0.236652 |
SPLIT TS1 | 0.268999 |
SPLIT TS2 | 0.269671 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
SPLIT GSW OA CONTROLLER | 0.203491 | 0.026898 |
SPLIT GNW OA CONTROLLER | 0.200917 | 0.025953 |
SPLIT OFFICE OA CONTROLLER | 0.547152 | 0.038104 |
SPLIT GNE OA CONTROLLER | 0.148040 | 0.025953 |
SPLIT GN1 OA CONTROLLER | 0.115461 | 0.025953 |
SPLIT GN2 OA CONTROLLER | 0.114182 | 0.025953 |
SPLIT GS1 OA CONTROLLER | 0.115348 | 0.025953 |
SPLIT GS2 OA CONTROLLER | 0.118851 | 0.025953 |
SPLIT MSW OA CONTROLLER | 0.546733 | 0.051906 |
SPLIT MNW OA CONTROLLER | 0.537562 | 0.051906 |
SPLIT MSE OA CONTROLLER | 0.463847 | 0.051906 |
SPLIT MNE OA CONTROLLER | 0.422397 | 0.051906 |
SPLIT MN1 OA CONTROLLER | 0.322737 | 0.051906 |
SPLIT MN2 OA CONTROLLER | 0.320618 | 0.051906 |
SPLIT MS1 OA CONTROLLER | 0.330645 | 0.051906 |
SPLIT MS2 OA CONTROLLER | 0.331859 | 0.051906 |
SPLIT TSW OA CONTROLLER | 0.378074 | 0.025953 |
SPLIT TNW OA CONTROLLER | 0.365614 | 0.025953 |
SPLIT TSE OA CONTROLLER | 0.338211 | 0.025953 |
SPLIT TNE OA CONTROLLER | 0.303390 | 0.025953 |
SPLIT TN1 OA CONTROLLER | 0.236535 | 0.025953 |
SPLIT TN2 OA CONTROLLER | 0.236652 | 0.025953 |
SPLIT TS1 OA CONTROLLER | 0.268999 | 0.025953 |
SPLIT TS2 OA CONTROLLER | 0.269671 | 0.025953 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity (gross) [W] | Rated Sensible Heat Ratio | |
SPLIT GSW COOLING COIL | 0.203491 | 3368.49 | 0.798655 |
SPLIT GNW COOLING COIL | 0.200917 | 3325.89 | 0.798655 |
SPLIT OFFICE COOLING COIL | 0.547152 | 9057.32 | 0.798655 |
SPLIT GNE COOLING COIL | 0.148040 | 2450.59 | 0.798655 |
SPLIT GN1 COOLING COIL | 0.115461 | 1911.29 | 0.798655 |
SPLIT GN2 COOLING COIL | 0.114182 | 1890.11 | 0.798655 |
SPLIT GS1 COOLING COIL | 0.115348 | 1909.42 | 0.798655 |
SPLIT GS2 COOLING COIL | 0.118851 | 1967.40 | 0.798655 |
SPLIT MSW COOLING COIL | 0.546733 | 9050.38 | 0.798655 |
SPLIT MNW COOLING COIL | 0.537562 | 8898.57 | 0.798655 |
SPLIT MSE COOLING COIL | 0.463847 | 7678.31 | 0.798655 |
SPLIT MNE COOLING COIL | 0.422397 | 6992.17 | 0.798655 |
SPLIT MN1 COOLING COIL | 0.322737 | 5342.45 | 0.798655 |
SPLIT MN2 COOLING COIL | 0.320618 | 5307.36 | 0.798655 |
SPLIT MS1 COOLING COIL | 0.330645 | 5473.34 | 0.798655 |
SPLIT MS2 COOLING COIL | 0.331859 | 5493.45 | 0.798655 |
SPLIT TSW COOLING COIL | 0.378074 | 6258.47 | 0.798655 |
SPLIT TNW COOLING COIL | 0.365614 | 6052.20 | 0.798655 |
SPLIT TSE COOLING COIL | 0.338211 | 5598.59 | 0.798655 |
SPLIT TNE COOLING COIL | 0.303390 | 5022.19 | 0.798655 |
SPLIT TN1 COOLING COIL | 0.236535 | 3915.49 | 0.798655 |
SPLIT TN2 COOLING COIL | 0.236652 | 3917.43 | 0.798655 |
SPLIT TS1 COOLING COIL | 0.268999 | 4452.89 | 0.798655 |
SPLIT TS2 COOLING COIL | 0.269671 | 4464.02 | 0.798655 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
SPLIT GSW FURNACE WITH DX COOLING | 0.203491 | 0.203491 | 0.203491 | 0.203491 | 2219.07 | 3368.49 | 1.00 |
SPLIT GNW FURNACE WITH DX COOLING | 0.200917 | 0.200917 | 0.200917 | 0.200917 | 2201.53 | 3325.89 | 1.00 |
SPLIT OFFICE FURNACE WITH DX COOLING | 0.547152 | 0.547152 | 0.547152 | 0.547152 | 4091.08 | 9057.32 | 1.00 |
SPLIT GNE FURNACE WITH DX COOLING | 0.148040 | 0.148040 | 0.148040 | 0.148040 | 2201.53 | 2450.59 | 1.00 |
SPLIT GN1 FURNACE WITH DX COOLING | 0.115461 | 0.115461 | 0.115461 | 0.115461 | 1610.17 | 1911.29 | 1.00 |
SPLIT GN2 FURNACE WITH DX COOLING | 0.114182 | 0.114182 | 0.114182 | 0.114182 | 1610.17 | 1890.11 | 1.00 |
SPLIT GS1 FURNACE WITH DX COOLING | 0.115348 | 0.115348 | 0.115348 | 0.115348 | 1601.92 | 1909.42 | 1.00 |
SPLIT GS2 FURNACE WITH DX COOLING | 0.118851 | 0.118851 | 0.118851 | 0.118851 | 1701.15 | 1967.40 | 1.00 |
SPLIT MSW FURNACE WITH DX COOLING | 0.546733 | 0.546733 | 0.546733 | 0.546733 | 4382.89 | 9050.38 | 1.00 |
SPLIT MNW FURNACE WITH DX COOLING | 0.537562 | 0.537562 | 0.537562 | 0.537562 | 4407.95 | 8898.57 | 1.00 |
SPLIT MSE FURNACE WITH DX COOLING | 0.463847 | 0.463847 | 0.463847 | 0.463847 | 4382.89 | 7678.31 | 1.00 |
SPLIT MNE FURNACE WITH DX COOLING | 0.422397 | 0.422397 | 0.422397 | 0.422397 | 4407.95 | 6992.17 | 1.00 |
SPLIT MN1 FURNACE WITH DX COOLING | 0.322737 | 0.322737 | 0.322737 | 0.322737 | 2990.99 | 5342.45 | 1.00 |
SPLIT MN2 FURNACE WITH DX COOLING | 0.320618 | 0.320618 | 0.320618 | 0.320618 | 2990.99 | 5307.36 | 1.00 |
SPLIT MS1 FURNACE WITH DX COOLING | 0.330645 | 0.330645 | 0.330645 | 0.330645 | 2990.99 | 5473.34 | 1.00 |
SPLIT MS2 FURNACE WITH DX COOLING | 0.331859 | 0.331859 | 0.331859 | 0.331859 | 2990.99 | 5493.45 | 1.00 |
SPLIT TSW FURNACE WITH DX COOLING | 0.378074 | 0.378074 | 0.378074 | 0.378074 | 3428.01 | 6258.47 | 1.00 |
SPLIT TNW FURNACE WITH DX COOLING | 0.365614 | 0.365614 | 0.365614 | 0.365614 | 3442.67 | 6052.20 | 1.00 |
SPLIT TSE FURNACE WITH DX COOLING | 0.338211 | 0.338211 | 0.338211 | 0.338211 | 3428.01 | 5598.59 | 1.00 |
SPLIT TNE FURNACE WITH DX COOLING | 0.303390 | 0.303390 | 0.303390 | 0.303390 | 3442.67 | 5022.19 | 1.00 |
SPLIT TN1 FURNACE WITH DX COOLING | 0.236535 | 0.236535 | 0.236535 | 0.236535 | 2638.78 | 3915.49 | 1.00 |
SPLIT TN2 FURNACE WITH DX COOLING | 0.236652 | 0.236652 | 0.236652 | 0.236652 | 2638.78 | 3917.43 | 1.00 |
SPLIT TS1 FURNACE WITH DX COOLING | 0.268999 | 0.268999 | 0.268999 | 0.268999 | 2622.14 | 4452.89 | 1.00 |
SPLIT TS2 FURNACE WITH DX COOLING | 0.269671 | 0.269671 | 0.269671 | 0.269671 | 2622.14 | 4464.02 | 1.00 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW SUPPLY FAN | 0.203491 |
SPLIT GNW SUPPLY FAN | 0.200917 |
SPLIT OFFICE SUPPLY FAN | 0.547152 |
SPLIT GNE SUPPLY FAN | 0.148040 |
SPLIT GN1 SUPPLY FAN | 0.115461 |
SPLIT GN2 SUPPLY FAN | 0.114182 |
SPLIT GS1 SUPPLY FAN | 0.115348 |
SPLIT GS2 SUPPLY FAN | 0.118851 |
SPLIT MSW SUPPLY FAN | 0.546733 |
SPLIT MNW SUPPLY FAN | 0.537562 |
SPLIT MSE SUPPLY FAN | 0.463847 |
SPLIT MNE SUPPLY FAN | 0.422397 |
SPLIT MN1 SUPPLY FAN | 0.322737 |
SPLIT MN2 SUPPLY FAN | 0.320618 |
SPLIT MS1 SUPPLY FAN | 0.330645 |
SPLIT MS2 SUPPLY FAN | 0.331859 |
SPLIT TSW SUPPLY FAN | 0.378074 |
SPLIT TNW SUPPLY FAN | 0.365614 |
SPLIT TSE SUPPLY FAN | 0.338211 |
SPLIT TNE SUPPLY FAN | 0.303390 |
SPLIT TN1 SUPPLY FAN | 0.236535 |
SPLIT TN2 SUPPLY FAN | 0.236652 |
SPLIT TS1 SUPPLY FAN | 0.268999 |
SPLIT TS2 SUPPLY FAN | 0.269671 |
Nominal Capacity [W] | |
SPLIT GSW HEATING COIL | 2219.07 |
SPLIT GNW HEATING COIL | 2201.53 |
SPLIT OFFICE HEATING COIL | 4091.08 |
SPLIT GNE HEATING COIL | 2201.53 |
SPLIT GN1 HEATING COIL | 1610.17 |
SPLIT GN2 HEATING COIL | 1610.17 |
SPLIT GS1 HEATING COIL | 1601.92 |
SPLIT GS2 HEATING COIL | 1701.15 |
SPLIT MSW HEATING COIL | 4382.89 |
SPLIT MNW HEATING COIL | 4407.95 |
SPLIT MSE HEATING COIL | 4382.89 |
SPLIT MNE HEATING COIL | 4407.95 |
SPLIT MN1 HEATING COIL | 2990.99 |
SPLIT MN2 HEATING COIL | 2990.99 |
SPLIT MS1 HEATING COIL | 2990.99 |
SPLIT MS2 HEATING COIL | 2990.99 |
SPLIT TSW HEATING COIL | 3428.01 |
SPLIT TNW HEATING COIL | 3442.67 |
SPLIT TSE HEATING COIL | 3428.01 |
SPLIT TNE HEATING COIL | 3442.67 |
SPLIT TN1 HEATING COIL | 2638.78 |
SPLIT TN2 HEATING COIL | 2638.78 |
SPLIT TS1 HEATING COIL | 2622.14 |
SPLIT TS2 HEATING COIL | 2622.14 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:12
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW1 S SWA | |
G WWALL SWA | GWINDOW1 W SWA | |
G NWALL NWA | GWINDOW1 N NWA | |
G WWALL NWA | GWINDOW1 W NWA | |
G SWALL SEA | GWINDOW1 S SEA | |
G EWALL SEA | GWINDOW1 E SEA | |
G NWALL NEA | GWINDOW1 N NEA | |
G EWALL NEA | GWINDOW1 E NEA | |
G NWALL N1A | GWINDOW1 N N1A | |
G NWALL N2A | GWINDOW1 N N2A | |
G SWALL S1A | GWINDOW1 S S1A | |
G SWALL S2A | GWINDOW1 S S2A | |
M WWALL SWA | MWINDOW1 W SWA | |
M SWALL SWA | MWINDOW1 S SWA | |
M NWALL NWA | MWINDOW1 N NWA | |
M WWALL NWA | MWINDOW1 W NWA | |
M EWALL SEA | MWINDOW1 E SEA | |
M SWALL SEA | MWINDOW1 S SEA | |
M NWALL NEA | MWINDOW1 N NEA | |
M EWALL NEA | MWINDOW1 E NEA | |
M NWALL N1A | MWINDOW1 N N1A | |
M NWALL N2A | MWINDOW1 N N2A | |
M SWALL S1A | MWINDOW1 S S1A | |
M SWALL S2A | MWINDOW1 S S2A | |
T WWALL SWA | TWINDOW1 W SWA | |
T SWALL SWA | TWINDOW1 S SWA | |
T NWALL NWA | TWINDOW1 N NWA | |
T WWALL NWA | TWINDOW1 W NWA | |
T EWALL SEA | TWINDOW1 E SEA | |
T SWALL SEA | TWINDOW1 S SEA | |
T NWALL NEA | TWINDOW1 N NEA | |
T EWALL NEA | TWINDOW1 E NEA | |
T NWALL N1A | TWINDOW1 N N1A | |
T NWALL N2A | TWINDOW1 N N2A | |
T SWALL S1A | TWINDOW1 S S1A | |
T SWALL S2A | TWINDOW1 S S2A | |
T EWALL C | TWINDOW14 | |
G EWALL C | ENTRANCE DOOR | |
M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:12
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.16 | 2.60 |
February | 22.27 | 4.29 |
March | 22.43 | 8.77 |
April | 23.16 | 13.91 |
May | 23.61 | 17.82 |
June | 24.32 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.39 | 20.49 |
October | 23.54 | 13.71 |
November | 22.59 | 6.96 |
December | 22.14 | 2.07 |
Annual Sum or Average | 23.29 | 13.68 |
Minimum of Months | 22.14 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.74 | 2.60 |
February | 21.82 | 4.29 |
March | 22.03 | 8.77 |
April | 22.86 | 13.91 |
May | 23.57 | 17.82 |
June | 24.33 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.38 | 20.49 |
October | 23.05 | 13.71 |
November | 21.89 | 6.96 |
December | 21.72 | 2.07 |
Annual Sum or Average | 23.02 | 13.68 |
Minimum of Months | 21.72 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.12 | 2.60 |
February | 22.42 | 4.29 |
March | 23.19 | 8.77 |
April | 24.37 | 13.91 |
May | 24.99 | 17.82 |
June | 26.46 | 23.21 |
July | 27.10 | 25.63 |
August | 26.83 | 24.08 |
September | 26.67 | 20.49 |
October | 24.76 | 13.71 |
November | 23.18 | 6.96 |
December | 22.17 | 2.07 |
Annual Sum or Average | 24.53 | 13.68 |
Minimum of Months | 22.12 | 2.07 |
Maximum of Months | 27.10 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | 2.60 |
February | 21.76 | 4.29 |
March | 21.95 | 8.77 |
April | 22.85 | 13.91 |
May | 23.54 | 17.82 |
June | 24.32 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.36 | 20.49 |
October | 22.96 | 13.71 |
November | 21.80 | 6.96 |
December | 21.70 | 2.07 |
Annual Sum or Average | 22.98 | 13.68 |
Minimum of Months | 21.70 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | 2.60 |
February | 21.75 | 4.29 |
March | 21.87 | 8.77 |
April | 22.60 | 13.91 |
May | 23.38 | 17.82 |
June | 24.32 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.37 | 20.49 |
October | 22.88 | 13.71 |
November | 21.80 | 6.96 |
December | 21.70 | 2.07 |
Annual Sum or Average | 22.94 | 13.68 |
Minimum of Months | 21.70 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | 2.60 |
February | 21.74 | 4.29 |
March | 21.87 | 8.77 |
April | 22.60 | 13.91 |
May | 23.38 | 17.82 |
June | 24.32 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.37 | 20.49 |
October | 22.87 | 13.71 |
November | 21.79 | 6.96 |
December | 21.70 | 2.07 |
Annual Sum or Average | 22.94 | 13.68 |
Minimum of Months | 21.70 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.17 | 2.60 |
February | 22.25 | 4.29 |
March | 22.36 | 8.77 |
April | 23.00 | 13.91 |
May | 23.47 | 17.82 |
June | 24.32 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.39 | 20.49 |
October | 23.55 | 13.71 |
November | 22.62 | 6.96 |
December | 22.16 | 2.07 |
Annual Sum or Average | 23.26 | 13.68 |
Minimum of Months | 22.16 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.17 | 2.60 |
February | 22.26 | 4.29 |
March | 22.39 | 8.77 |
April | 23.05 | 13.91 |
May | 23.52 | 17.82 |
June | 24.33 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.39 | 20.49 |
October | 23.58 | 13.71 |
November | 22.64 | 6.96 |
December | 22.17 | 2.07 |
Annual Sum or Average | 23.28 | 13.68 |
Minimum of Months | 22.17 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.06 | 2.60 |
February | 23.23 | 4.29 |
March | 23.79 | 8.77 |
April | 24.28 | 13.91 |
May | 24.34 | 17.82 |
June | 24.39 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 24.23 | 13.71 |
November | 23.90 | 6.96 |
December | 23.10 | 2.07 |
Annual Sum or Average | 23.96 | 13.68 |
Minimum of Months | 23.06 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.94 | 2.60 |
February | 22.23 | 4.29 |
March | 23.11 | 8.77 |
April | 24.19 | 13.91 |
May | 24.33 | 17.82 |
June | 24.39 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 24.01 | 13.71 |
November | 22.82 | 6.96 |
December | 21.86 | 2.07 |
Annual Sum or Average | 23.51 | 13.68 |
Minimum of Months | 21.86 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.01 | 2.60 |
February | 23.14 | 4.29 |
March | 23.76 | 8.77 |
April | 24.28 | 13.91 |
May | 24.35 | 17.82 |
June | 24.39 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 24.21 | 13.71 |
November | 23.85 | 6.96 |
December | 23.05 | 2.07 |
Annual Sum or Average | 23.94 | 13.68 |
Minimum of Months | 23.01 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.87 | 2.60 |
February | 22.12 | 4.29 |
March | 23.05 | 8.77 |
April | 24.18 | 13.91 |
May | 24.34 | 17.82 |
June | 24.39 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 23.95 | 13.71 |
November | 22.63 | 6.96 |
December | 21.77 | 2.07 |
Annual Sum or Average | 23.46 | 13.68 |
Minimum of Months | 21.77 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.93 | 2.60 |
February | 22.21 | 4.29 |
March | 23.23 | 8.77 |
April | 24.23 | 13.91 |
May | 24.35 | 17.82 |
June | 24.40 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 24.07 | 13.71 |
November | 22.92 | 6.96 |
December | 21.84 | 2.07 |
Annual Sum or Average | 23.54 | 13.68 |
Minimum of Months | 21.84 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.92 | 2.60 |
February | 22.20 | 4.29 |
March | 23.23 | 8.77 |
April | 24.23 | 13.91 |
May | 24.36 | 17.82 |
June | 24.40 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 24.06 | 13.71 |
November | 22.90 | 6.96 |
December | 21.84 | 2.07 |
Annual Sum or Average | 23.53 | 13.68 |
Minimum of Months | 21.84 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.43 | 2.60 |
February | 23.57 | 4.29 |
March | 24.03 | 8.77 |
April | 24.33 | 13.91 |
May | 24.37 | 17.82 |
June | 24.40 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 24.30 | 13.71 |
November | 24.13 | 6.96 |
December | 23.53 | 2.07 |
Annual Sum or Average | 24.11 | 13.68 |
Minimum of Months | 23.43 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.42 | 2.60 |
February | 23.56 | 4.29 |
March | 24.03 | 8.77 |
April | 24.33 | 13.91 |
May | 24.37 | 17.82 |
June | 24.40 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.40 | 20.49 |
October | 24.30 | 13.71 |
November | 24.13 | 6.96 |
December | 23.53 | 2.07 |
Annual Sum or Average | 24.11 | 13.68 |
Minimum of Months | 23.42 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.50 | 2.60 |
February | 22.68 | 4.29 |
March | 22.96 | 8.77 |
April | 23.77 | 13.91 |
May | 24.12 | 17.82 |
June | 24.34 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.38 | 20.49 |
October | 23.78 | 13.71 |
November | 23.02 | 6.96 |
December | 22.54 | 2.07 |
Annual Sum or Average | 23.58 | 13.68 |
Minimum of Months | 22.50 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.94 | 2.60 |
February | 22.16 | 4.29 |
March | 22.62 | 8.77 |
April | 23.63 | 13.91 |
May | 24.10 | 17.82 |
June | 24.34 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.37 | 20.49 |
October | 23.52 | 13.71 |
November | 22.34 | 6.96 |
December | 21.83 | 2.07 |
Annual Sum or Average | 23.31 | 13.68 |
Minimum of Months | 21.83 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.49 | 2.60 |
February | 22.67 | 4.29 |
March | 22.97 | 8.77 |
April | 23.80 | 13.91 |
May | 24.13 | 17.82 |
June | 24.34 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.37 | 20.49 |
October | 23.77 | 13.71 |
November | 23.01 | 6.96 |
December | 22.55 | 2.07 |
Annual Sum or Average | 23.58 | 13.68 |
Minimum of Months | 22.49 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.85 | 2.60 |
February | 22.10 | 4.29 |
March | 22.63 | 8.77 |
April | 23.66 | 13.91 |
May | 24.08 | 17.82 |
June | 24.33 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.35 | 20.49 |
October | 23.50 | 13.71 |
November | 22.23 | 6.96 |
December | 21.75 | 2.07 |
Annual Sum or Average | 23.28 | 13.68 |
Minimum of Months | 21.75 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.84 | 2.60 |
February | 22.08 | 4.29 |
March | 22.58 | 8.77 |
April | 23.65 | 13.91 |
May | 24.12 | 17.82 |
June | 24.36 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.38 | 20.49 |
October | 23.51 | 13.71 |
November | 22.22 | 6.96 |
December | 21.75 | 2.07 |
Annual Sum or Average | 23.28 | 13.68 |
Minimum of Months | 21.75 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.84 | 2.60 |
February | 22.07 | 4.29 |
March | 22.58 | 8.77 |
April | 23.65 | 13.91 |
May | 24.12 | 17.82 |
June | 24.36 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.38 | 20.49 |
October | 23.52 | 13.71 |
November | 22.21 | 6.96 |
December | 21.75 | 2.07 |
Annual Sum or Average | 23.28 | 13.68 |
Minimum of Months | 21.75 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.59 | 2.60 |
February | 22.79 | 4.29 |
March | 23.08 | 8.77 |
April | 23.85 | 13.91 |
May | 24.17 | 17.82 |
June | 24.36 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.39 | 20.49 |
October | 23.87 | 13.71 |
November | 23.15 | 6.96 |
December | 22.65 | 2.07 |
Annual Sum or Average | 23.65 | 13.68 |
Minimum of Months | 22.59 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.59 | 2.60 |
February | 22.79 | 4.29 |
March | 23.08 | 8.77 |
April | 23.85 | 13.91 |
May | 24.17 | 17.82 |
June | 24.36 | 23.21 |
July | 24.40 | 25.63 |
August | 24.40 | 24.08 |
September | 24.39 | 20.49 |
October | 23.87 | 13.71 |
November | 23.15 | 6.96 |
December | 22.65 | 2.07 |
Annual Sum or Average | 23.65 | 13.68 |
Minimum of Months | 22.59 | 2.07 |
Maximum of Months | 24.40 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.08 | 2.60 |
February | 22.53 | 4.29 |
March | 23.45 | 8.77 |
April | 24.99 | 13.91 |
May | 25.78 | 17.82 |
June | 26.63 | 23.21 |
July | 27.03 | 25.63 |
August | 26.90 | 24.08 |
September | 26.38 | 20.49 |
October | 24.87 | 13.71 |
November | 23.09 | 6.96 |
December | 21.99 | 2.07 |
Annual Sum or Average | 24.65 | 13.68 |
Minimum of Months | 21.99 | 2.07 |
Maximum of Months | 27.03 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.90 | 2.60 |
February | 20.31 | 4.29 |
March | 21.30 | 8.77 |
April | 22.69 | 13.91 |
May | 23.76 | 17.82 |
June | 26.10 | 23.21 |
July | 26.76 | 25.63 |
August | 26.49 | 24.08 |
September | 25.82 | 20.49 |
October | 23.10 | 13.71 |
November | 21.03 | 6.96 |
December | 19.82 | 2.07 |
Annual Sum or Average | 23.10 | 13.68 |
Minimum of Months | 19.82 | 2.07 |
Maximum of Months | 26.76 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2015-09-09 18:47:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.12 | 2.60 |
February | 24.38 | 4.29 |
March | 25.26 | 8.77 |
April | 26.27 | 13.91 |
May | 26.51 | 17.82 |
June | 26.83 | 23.21 |
July | 26.96 | 25.63 |
August | 26.92 | 24.08 |
September | 26.76 | 20.49 |
October | 26.20 | 13.71 |
November | 25.17 | 6.96 |
December | 24.09 | 2.07 |
Annual Sum or Average | 25.79 | 13.68 |
Minimum of Months | 24.09 | 2.07 |
Maximum of Months | 26.96 | 25.63 |
Report: PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2015-09-09 18:47:12
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [Invalid/Undefined] | HEATREJECTION:ELECTRICITY [Invalid/Undefined] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined] | |
January | 0.118549E+12 | 72050.147 | 01-JAN-18:15 | 4979.953 | 26630.920 | 8400.977 | 0.000 | 968.957 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 28516.339 | 0.000 | 0.000 | 0.000 |
February | 0.107420E+12 | 73234.668 | 19-FEB-18:30 | 4979.953 | 26630.920 | 8400.977 | 0.000 | 1541.961 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 29127.856 | 0.000 | 0.000 | 0.000 |
March | 0.118639E+12 | 70758.034 | 08-MAR-18:00 | 4979.953 | 26630.920 | 8400.977 | 0.000 | 2160.618 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 26032.565 | 0.000 | 0.000 | 0.000 |
April | 0.118284E+12 | 74180.056 | 13-APR-16:45 | 4276.255 | 26730.986 | 8400.977 | 0.000 | 12886.341 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 21885.496 | 0.000 | 0.000 | 0.000 |
May | 0.124690E+12 | 78420.022 | 19-MAY-17:30 | 4979.953 | 26630.920 | 8400.977 | 0.000 | 16017.001 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 22391.170 | 0.000 | 0.000 | 0.000 |
June | 0.129868E+12 | 81623.131 | 28-JUN-17:15 | 4979.953 | 26630.920 | 8400.977 | 0.000 | 22303.896 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 19307.383 | 0.000 | 0.000 | 0.000 |
July | 0.140147E+12 | 82340.841 | 21-JUL-17:30 | 4979.953 | 26630.920 | 8400.977 | 0.000 | 22755.176 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 19573.814 | 0.000 | 0.000 | 0.000 |
August | 0.137216E+12 | 79569.826 | 20-AUG-17:30 | 4979.953 | 26630.920 | 8400.977 | 0.000 | 20674.710 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18883.265 | 0.000 | 0.000 | 0.000 |
September | 0.125847E+12 | 78618.743 | 02-SEP-17:45 | 4979.953 | 26630.920 | 8400.977 | 0.000 | 16330.136 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 22276.756 | 0.000 | 0.000 | 0.000 |
October | 0.121337E+12 | 74560.103 | 04-OCT-17:45 | 4979.953 | 26630.920 | 8400.977 | 0.000 | 10713.280 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 21281.971 | 0.000 | 0.000 | 0.000 |
November | 0.112964E+12 | 68361.792 | 22-NOV-18:15 | 4979.953 | 26630.920 | 8400.977 | 0.000 | 2724.797 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23072.144 | 0.000 | 0.000 | 0.000 |
December | 0.117047E+12 | 70903.165 | 31-DEC-18:30 | 4979.953 | 26630.920 | 8400.977 | 0.000 | 1540.430 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 26797.884 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.147201E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||
Minimum of Months | 0.107420E+12 | 68361.792 | 4276.255 | 26630.920 | 8400.977 | 0.000 | 968.957 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 18883.265 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.140147E+12 | 82340.841 | 4979.953 | 26730.986 | 8400.977 | 0.000 | 22755.176 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 29127.856 | 0.000 | 0.000 | 0.000 |
Report: PEAK GAS DEMAND
For: Meter
Timestamp: 2015-09-09 18:47:12
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC {AT MAX/MIN} [W] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT [Invalid/Undefined] | WATERSYSTEMS:GAS [Invalid/Undefined] | WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.373039E+11 | 60925.697 | 18-JAN-01:15 | 60925.697 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 60925.697 |
February | 0.264112E+11 | 59335.752 | 06-FEB-04:00 | 59335.752 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 59335.752 |
March | 0.104531E+11 | 35447.678 | 04-MAR-05:00 | 35447.678 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 35447.678 |
April | 0.183089E+10 | 14959.375 | 08-APR-01:00 | 14959.375 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 14959.375 |
May | 0.487201E+09 | 9546.112 | 05-MAY-04:00 | 9546.112 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 9546.112 |
June | 296808.060 | 166.462 | 09-JUN-04:45 | 166.462 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 166.462 |
July | 0.000 | 0.000 | 01-JUL-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.000 | 0.000 | 01-AUG-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.000 | 0.000 | 01-SEP-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
October | 0.278564E+10 | 25889.244 | 26-OCT-03:00 | 25889.244 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 25889.244 |
November | 0.119365E+11 | 40187.500 | 26-NOV-05:00 | 40187.500 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 40187.500 |
December | 0.359691E+11 | 60798.425 | 14-DEC-03:00 | 60798.425 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 60798.425 |
Annual Sum or Average | 0.127178E+12 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | ||||
Minimum of Months | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.373039E+11 | 60925.697 | 60925.697 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 60925.697 |