Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:47

Tabular Output Report in Format: HTML

Building: Mid-Rise Apartment

Environment: El Paso International Ap Ut TX USA TMY3 WMO#=722700

Simulation Timestamp: 2015-09-09 18:47:31


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:31

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 1521.56 485.41 538.80
Net Site Energy 1521.56 485.41 538.80
Total Source Energy 4716.25 1504.57 1670.07
Net Source Energy 4716.25 1504.57 1670.07


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 3134.61
Net Conditioned Building Area 2823.98
Unconditioned Building Area 310.64


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 0.00 49.22 0.00 0.00 0.00 0.00
Cooling 193.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 118.46 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 40.15 0.00 0.00 0.00 0.00 0.00
Interior Equipment 517.65 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 255.54 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 347.53 0.00 0.00 0.00 0.00 1874.72
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 1472.34 49.22 0.00 0.00 0.00 1874.72
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating General 0.00 49.22 0.00 0.00 0.00 0.00
Cooling General 193.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 96.36 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 22.11 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 40.15 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 517.65 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 255.54 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 347.53 0.00 0.00 0.00 0.00 1874.72
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 56.16 0.00 0.00 0.00 0.00 0.00
HVAC 281.90 17.43 0.00 0.00 0.00 0.66
Other 183.31 0.00 0.00 0.00 0.00 0.00
Total 521.37 17.43 0.00 0.00 0.00 0.66


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 50.60 0.00 0.00 0.00 0.00 0.00
HVAC 253.96 15.70 0.00 0.00 0.00 0.60
Other 165.14 0.00 0.00 0.00 0.00 0.00
Total 469.70 15.70 0.00 0.00 0.00 0.60


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 1472.34 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 1472.34 100.00
     
Total On-Site and Utility Electric Sources 1472.34 100.00
Total Electricity End Uses 1472.34 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 1874.72 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 1874.72 100.00
Total Water End Uses 1874.72 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 34.25
Time Setpoint Not Met During Occupied Cooling 3.50
Time Not Comfortable Based on Simple ASHRAE 55-2004 878.75


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |

PEAK ELECTRICAL DEMAND

| Meter |

PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:31

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:47
RunPeriod El Paso International Ap Ut TX USA TMY3 WMO#=722700
Weather File El Paso International Ap Ut TX USA TMY3 WMO#=722700
Latitude [deg] 31.77
Longitude [deg] -106.5
Elevation [m] 1186.00
Time Zone -7.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1542.04 564.80 206.22 564.80 206.22
Window Opening Area [m2] 306.92 112.97 37.16 112.97 43.82
Window-Wall Ratio [%] 19.90 20.00 18.02 20.00 21.25


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1501.17 564.80 185.79 564.80 185.79
Window Opening Area [m2] 300.26 112.97 37.16 112.97 37.16
Window-Wall Ratio [%] 20.00 20.00 20.00 20.00 20.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
OFFICE 88.25 Yes Yes 268.97 1.00 58.52 11.71 26.1977 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
M SW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 3.6746 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 3.6746 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 3.6746 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 3.6746 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 3.6746 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 3.6746 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 3.6746 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 3.6746 35.30 6.6700
T SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 1.11 5.9540   0.0000
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 3.32 5.9540   208.8202
M CORRIDOR 77.66 No Yes 236.69 2.00 10.22 1.11 5.9540   0.0000
Total 3134.61     9553.84   1542.04 306.92 4.5346 39.93 11.1825
Conditioned Total 2823.98     8607.06   1501.17 300.26 4.3785 35.97 6.6700
Unconditioned Total 310.64     946.78   40.87 6.66 5.9540   52.2051
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:31

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 26-JUL-17:45 28-JAN-05:00 - - - 01-JAN-07:15
Heating 0.00 38020.19 0.00 0.00 0.00 0.00
Cooling 22630.76 0.00 0.00 0.00 0.00 0.00
Interior Lighting 4979.95 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 26630.92 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 8103.11 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 21556.18 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 83900.92 38020.19 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating General 0.00 38020.19 0.00 0.00 0.00 0.00
Cooling General 22630.76 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 4056.31 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 923.64 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 26630.92 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 8103.11 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 21556.18 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:31

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 0.00 53.36 0.00 0.00 0.00
Cooling 611.24 0.00 0.00 0.00 0.00
Interior Lighting 375.17 0.00 0.00 0.00 0.00
Exterior Lighting 127.14 0.00 0.00 0.00 0.00
Interior Equipment 1639.40 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 809.29 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 1100.64 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 4662.89 53.36 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 18.89 0.00 0.00 0.00
Cooling 216.45 0.00 0.00 0.00 0.00
Interior Lighting 132.85 0.00 0.00 0.00 0.00
Exterior Lighting 45.02 0.00 0.00 0.00 0.00
Interior Equipment 580.53 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 286.58 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 389.75 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1651.18 18.89 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 18.89 0.00 0.00 0.00
Cooling 216.45 0.00 0.00 0.00 0.00
Interior Lighting 132.85 0.00 0.00 0.00 0.00
Exterior Lighting 45.02 0.00 0.00 0.00 0.00
Interior Equipment 580.53 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 286.58 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 389.75 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1651.18 18.89 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:31

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB -5.20 0.00 -5.20 Wetbulb [C] 2.20 20.00
EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 38.10 13.00 18.10 Wetbulb [C] 3.90 280.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:31

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
M WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 46.45 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 46.45 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 46.45 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 46.45 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
T WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.30 0.269 0.283 77.66 180.00 0.00  
G WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 90.00 180.00  
M WWALL C RES_EXT_WALL 0.30 0.363 0.384 10.22 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.363 0.384 10.22 90.00 90.00 E


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW1 S SWA WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 2.848 0.287 0.200     No G SWALL SWA 180.00 90.00 S
GWINDOW1 W SWA WINDOW_U_0.62_SHGC_0.25 4.65 0.00 0.00 4.65 4.65 2.848 0.287 0.200     No G WWALL SWA 270.00 90.00 W
GWINDOW1 N NWA WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 2.848 0.287 0.200     No G NWALL NWA 0.00 90.00 N
GWINDOW1 W NWA WINDOW_U_0.62_SHGC_0.25 4.65 0.00 0.00 4.65 4.65 2.848 0.287 0.200     No G WWALL NWA 270.00 90.00 W
GWINDOW1 S SEA WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 2.848 0.287 0.200     No G SWALL SEA 180.00 90.00 S
GWINDOW1 E SEA WINDOW_U_0.62_SHGC_0.25 4.65 0.00 0.00 4.65 4.65 2.848 0.287 0.200     No G EWALL SEA 90.00 90.00 E
GWINDOW1 N NEA WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 2.848 0.287 0.200     No G NWALL NEA 0.00 90.00 N
GWINDOW1 E NEA WINDOW_U_0.62_SHGC_0.25 4.65 0.00 0.00 4.65 4.65 2.848 0.287 0.200     No G EWALL NEA 90.00 90.00 E
GWINDOW1 N N1A WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 2.848 0.287 0.200     No G NWALL N1A 0.00 90.00 N
GWINDOW1 N N2A WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 2.848 0.287 0.200     No G NWALL N2A 0.00 90.00 N
GWINDOW1 S S1A WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 2.848 0.287 0.200     No G SWALL S1A 180.00 90.00 S
GWINDOW1 S S2A WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 2.848 0.287 0.200     No G SWALL S2A 180.00 90.00 S
MWINDOW1 W SWA WINDOW_U_0.62_SHGC_0.25 4.65 0.00 0.00 4.65 9.29 2.848 0.287 0.200     No M WWALL SWA 270.00 90.00 W
MWINDOW1 S SWA WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 14.12 2.848 0.287 0.200     No M SWALL SWA 180.00 90.00 S
MWINDOW1 N NWA WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 14.12 2.848 0.287 0.200     No M NWALL NWA 0.00 90.00 N
MWINDOW1 W NWA WINDOW_U_0.62_SHGC_0.25 4.65 0.00 0.00 4.65 9.29 2.848 0.287 0.200     No M WWALL NWA 270.00 90.00 W
MWINDOW1 E SEA WINDOW_U_0.62_SHGC_0.25 4.65 0.00 0.00 4.65 9.29 2.848 0.287 0.200     No M EWALL SEA 90.00 90.00 E
MWINDOW1 S SEA WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 14.12 2.848 0.287 0.200     No M SWALL SEA 180.00 90.00 S
MWINDOW1 N NEA WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 14.12 2.848 0.287 0.200     No M NWALL NEA 0.00 90.00 N
MWINDOW1 E NEA WINDOW_U_0.62_SHGC_0.25 4.65 0.00 0.00 4.65 9.29 2.848 0.287 0.200     No M EWALL NEA 90.00 90.00 E
MWINDOW1 N N1A WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 14.12 2.848 0.287 0.200     No M NWALL N1A 0.00 90.00 N
MWINDOW1 N N2A WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 14.12 2.848 0.287 0.200     No M NWALL N2A 0.00 90.00 N
MWINDOW1 S S1A WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 14.12 2.848 0.287 0.200     No M SWALL S1A 180.00 90.00 S
MWINDOW1 S S2A WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 14.12 2.848 0.287 0.200     No M SWALL S2A 180.00 90.00 S
TWINDOW1 W SWA WINDOW_U_0.62_SHGC_0.25 4.65 0.00 0.00 4.65 4.65 2.848 0.287 0.200     No T WWALL SWA 270.00 90.00 W
TWINDOW1 S SWA WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 2.848 0.287 0.200     No T SWALL SWA 180.00 90.00 S
TWINDOW1 N NWA WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 2.848 0.287 0.200     No T NWALL NWA 0.00 90.00 N
TWINDOW1 W NWA WINDOW_U_0.62_SHGC_0.25 4.65 0.00 0.00 4.65 4.65 2.848 0.287 0.200     No T WWALL NWA 270.00 90.00 W
TWINDOW1 E SEA WINDOW_U_0.62_SHGC_0.25 4.65 0.00 0.00 4.65 4.65 2.848 0.287 0.200     No T EWALL SEA 90.00 90.00 E
TWINDOW1 S SEA WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 2.848 0.287 0.200     No T SWALL SEA 180.00 90.00 S
TWINDOW1 N NEA WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 2.848 0.287 0.200     No T NWALL NEA 0.00 90.00 N
TWINDOW1 E NEA WINDOW_U_0.62_SHGC_0.25 4.65 0.00 0.00 4.65 4.65 2.848 0.287 0.200     No T EWALL NEA 90.00 90.00 E
TWINDOW1 N N1A WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 2.848 0.287 0.200     No T NWALL N1A 0.00 90.00 N
TWINDOW1 N N2A WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 2.848 0.287 0.200     No T NWALL N2A 0.00 90.00 N
TWINDOW1 S S1A WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 2.848 0.287 0.200     No T SWALL S1A 180.00 90.00 S
TWINDOW1 S S2A WINDOW_U_0.62_SHGC_0.25 7.06 0.00 0.00 7.06 7.06 2.848 0.287 0.200     No T SWALL S2A 180.00 90.00 S
TWINDOW14 WINDOW_U_0.62_SHGC_0.25 1.11 0.00 0.00 1.11 1.11 2.848 0.287 0.200     No T EWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.62_SHGC_0.25 3.32 0.00 0.00 3.32 3.32 2.848 0.287 0.200     No G EWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.62_SHGC_0.25 1.11 0.00 0.00 1.11 2.23 2.848 0.287 0.200     No M EWALL C 270.00 90.00 W
Total or Average           306.92 2.848 0.287 0.200              
North Total or Average           112.97 2.848 0.287 0.200              
Non-North Total or Average           193.95 2.848 0.287 0.200              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:31

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW1 S SWA 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 N NWA 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 S SEA 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW1 N NEA 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW1 N N1A 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 N N2A 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 S S1A 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 S S2A 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW1 S SWA 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 N NWA 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 S SEA 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 N NEA 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 N N1A 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 N N2A 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 S S1A 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 S S2A 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW1 S SWA 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 N NWA 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 S SEA 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 N NEA 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 N N1A 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 N N2A 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 S S1A 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 S S2A 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:31

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
LIGHTING_HARDWIRED_GSW G SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GNW G NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_OFFICE OFFICE 13.0989 88.25 1155.96 GeneralLights LTG_OFF_SCH 62.17 168.00 60.95 0.0000 Y 13.23
LIGHTING_HARDWIRED_GNE G NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GN1 G N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GN2 G N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GS1 G S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GS2 G S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MSW M SW APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MNW M NW APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MSE M SE APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MNE M NE APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MN1 M N1 APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MN2 M N2 APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MS1 M S1 APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MS2 M S2 APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TSW T SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TNW T NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TSE T SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TNE T NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TN1 T N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TN2 T N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TS1 T S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TS2 T S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GC G CORRIDOR 5.9540 77.66 462.39 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 14.58
LIGHTING_HARDWIRED_MC M CORRIDOR 5.9540 155.32 924.77 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 14.58
LIGHTING_HARDWIRED_TC T CORRIDOR 5.9540 77.66 462.39 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 14.58
LIGHTING_PLUGIN_GSW G SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_GNW G NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_OFFICE OFFICE 13.0989 88.25 1155.96 GeneralLights-plugin LTG_OFF_SCH 62.17 168.00 60.95 0.0000 Y 13.23
LIGHTING_PLUGIN_GNE G NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_GN1 G N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_GN2 G N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_GS1 G S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_GS2 G S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MSW M SW APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MNW M NW APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MSE M SE APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MNE M NE APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MN1 M N1 APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MN2 M N2 APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MS1 M S1 APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MS2 M S2 APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TSW T SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TNW T NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TSE T SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TNE T NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TN1 T N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TN2 T N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TS1 T S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TS2 T S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
Interior Lighting Total   2.3855 5958.59 14214.30               95.19


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 2553.00 AstronomicalClock -   83.77 83.77 40.15
Exterior Lighting Total 2553.00           40.15



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:31

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
None          


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
SPLIT GSW COOLING COIL Coil:Cooling:DX:SingleSpeed   3238.79 2586.68 652.11 0.80 3.91    
SPLIT GNW COOLING COIL Coil:Cooling:DX:SingleSpeed   3214.51 2567.28 647.22 0.80 3.91    
SPLIT OFFICE COOLING COIL Coil:Cooling:DX:SingleSpeed   8722.60 6966.35 1756.25 0.80 3.91    
SPLIT GNE COOLING COIL Coil:Cooling:DX:SingleSpeed   2574.86 2056.43 518.44 0.80 3.91    
SPLIT GN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   2018.24 1611.88 406.36 0.80 3.91    
SPLIT GN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   2005.65 1601.83 403.83 0.80 3.91    
SPLIT GS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   1973.91 1576.47 397.44 0.80 3.91    
SPLIT GS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   2099.96 1640.94 459.02 0.78 3.91    
SPLIT MSW COOLING COIL Coil:Cooling:DX:SingleSpeed   8227.20 6570.69 1656.50 0.80 3.91    
SPLIT MNW COOLING COIL Coil:Cooling:DX:SingleSpeed   8160.59 6517.50 1643.09 0.80 3.91    
SPLIT MSE COOLING COIL Coil:Cooling:DX:SingleSpeed   7185.49 5738.73 1446.76 0.80 3.91    
SPLIT MNE COOLING COIL Coil:Cooling:DX:SingleSpeed   6774.24 5410.28 1363.96 0.80 3.91    
SPLIT MN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   5264.22 4204.30 1059.92 0.80 3.91    
SPLIT MN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   5243.97 4188.13 1055.85 0.80 3.91    
SPLIT MS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   5294.44 4189.51 1104.93 0.79 3.91    
SPLIT MS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   5305.85 4198.98 1106.88 0.79 3.91    
SPLIT TSW COOLING COIL Coil:Cooling:DX:SingleSpeed   5871.35 4689.18 1182.17 0.80 3.91    
SPLIT TNW COOLING COIL Coil:Cooling:DX:SingleSpeed   5726.07 4573.16 1152.91 0.80 3.91    
SPLIT TSE COOLING COIL Coil:Cooling:DX:SingleSpeed   5356.85 4278.28 1078.57 0.80 3.91    
SPLIT TNE COOLING COIL Coil:Cooling:DX:SingleSpeed   5031.75 4018.63 1013.12 0.80 3.91    
SPLIT TN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   3987.09 3184.31 802.78 0.80 3.91    
SPLIT TN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   3986.98 3184.22 802.76 0.80 3.91    
SPLIT TS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   4294.29 3429.66 864.63 0.80 3.91    
SPLIT TS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   4300.53 3434.64 865.89 0.80 3.91    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
SPLIT GSW COOLING COIL Coil:Cooling:DX:SingleSpeed 3085.5 3.13 10.67 11.09 10.38
SPLIT GNW COOLING COIL Coil:Cooling:DX:SingleSpeed 3062.3 3.13 10.67 11.09 10.38
SPLIT OFFICE COOLING COIL Coil:Cooling:DX:SingleSpeed 8309.7 3.13 10.67 11.09 10.38
SPLIT GNE COOLING COIL Coil:Cooling:DX:SingleSpeed 2453.0 3.13 10.67 11.09 10.38
SPLIT GN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 1922.7 3.13 10.67 11.09 10.38
SPLIT GN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 1910.7 3.13 10.67 11.09 10.38
SPLIT GS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 1880.5 3.13 10.67 11.09 10.38
SPLIT GS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 2005.1 3.16 10.77 11.20 10.52
SPLIT MSW COOLING COIL Coil:Cooling:DX:SingleSpeed 7837.7 3.13 10.67 11.09 10.38
SPLIT MNW COOLING COIL Coil:Cooling:DX:SingleSpeed 7774.2 3.13 10.67 11.09 10.38
SPLIT MSE COOLING COIL Coil:Cooling:DX:SingleSpeed 6845.3 3.13 10.67 11.09 10.38
SPLIT MNE COOLING COIL Coil:Cooling:DX:SingleSpeed 6453.5 3.13 10.67 11.09 10.38
SPLIT MN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 5015.0 3.13 10.67 11.09 10.38
SPLIT MN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 4995.7 3.13 10.67 11.09 10.38
SPLIT MS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 5048.7 3.14 10.71 11.14 10.44
SPLIT MS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 5059.6 3.14 10.71 11.13 10.44
SPLIT TSW COOLING COIL Coil:Cooling:DX:SingleSpeed 5593.4 3.13 10.67 11.09 10.38
SPLIT TNW COOLING COIL Coil:Cooling:DX:SingleSpeed 5455.0 3.13 10.67 11.09 10.38
SPLIT TSE COOLING COIL Coil:Cooling:DX:SingleSpeed 5103.2 3.13 10.67 11.09 10.38
SPLIT TNE COOLING COIL Coil:Cooling:DX:SingleSpeed 4793.5 3.13 10.67 11.09 10.38
SPLIT TN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 3798.3 3.13 10.67 11.09 10.38
SPLIT TN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 3798.2 3.13 10.67 11.09 10.38
SPLIT TS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 4091.0 3.13 10.67 11.09 10.38
SPLIT TS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 4096.9 3.13 10.67 11.09 10.38
ANSI/AHRI ratings include supply fan

DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
SPLIT GSW HEATING COIL Coil:Heating:Gas   1946.11 0.80
SPLIT GNW HEATING COIL Coil:Heating:Gas   1928.35 0.80
SPLIT OFFICE HEATING COIL Coil:Heating:Gas   3616.86 0.80
SPLIT GNE HEATING COIL Coil:Heating:Gas   1933.09 0.80
SPLIT GN1 HEATING COIL Coil:Heating:Gas   1503.38 0.80
SPLIT GN2 HEATING COIL Coil:Heating:Gas   1503.38 0.80
SPLIT GS1 HEATING COIL Coil:Heating:Gas   1503.38 0.80
SPLIT GS2 HEATING COIL Coil:Heating:Gas   1504.62 0.80
SPLIT MSW HEATING COIL Coil:Heating:Gas   3739.52 0.80
SPLIT MNW HEATING COIL Coil:Heating:Gas   3761.73 0.80
SPLIT MSE HEATING COIL Coil:Heating:Gas   3752.38 0.80
SPLIT MNE HEATING COIL Coil:Heating:Gas   3774.58 0.80
SPLIT MN1 HEATING COIL Coil:Heating:Gas   3006.76 0.80
SPLIT MN2 HEATING COIL Coil:Heating:Gas   3006.76 0.80
SPLIT MS1 HEATING COIL Coil:Heating:Gas   3006.76 0.80
SPLIT MS2 HEATING COIL Coil:Heating:Gas   3006.76 0.80
SPLIT TSW HEATING COIL Coil:Heating:Gas   2971.95 0.80
SPLIT TNW HEATING COIL Coil:Heating:Gas   2985.12 0.80
SPLIT TSE HEATING COIL Coil:Heating:Gas   2978.70 0.80
SPLIT TNE HEATING COIL Coil:Heating:Gas   2991.88 0.80
SPLIT TN1 HEATING COIL Coil:Heating:Gas   2320.77 0.80
SPLIT TN2 HEATING COIL Coil:Heating:Gas   2320.96 0.80
SPLIT TS1 HEATING COIL Coil:Heating:Gas   2305.62 0.80
SPLIT TS2 HEATING COIL Coil:Heating:Gas   2305.82 0.80


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
SPLIT GSW SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 227.12 1160.84 1.00 General
SPLIT GNW SUPPLY FAN Fan:OnOff 0.54 622.50 0.19 225.42 1160.84 1.00 General
SPLIT OFFICE SUPPLY FAN Fan:OnOff 0.54 622.50 0.53 611.68 1160.84 1.00 General
SPLIT GNE SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 180.57 1160.84 1.00 General
SPLIT GN1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 141.53 1160.84 1.00 General
SPLIT GN2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 140.65 1160.84 1.00 General
SPLIT GS1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 138.42 1160.84 1.00 General
SPLIT GS2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 140.36 1160.84 1.00 General
SPLIT MSW SUPPLY FAN Fan:OnOff 0.54 622.50 0.50 576.94 1160.84 1.00 General
SPLIT MNW SUPPLY FAN Fan:OnOff 0.54 622.50 0.49 572.27 1160.84 1.00 General
SPLIT MSE SUPPLY FAN Fan:OnOff 0.54 622.50 0.43 503.89 1160.84 1.00 General
SPLIT MNE SUPPLY FAN Fan:OnOff 0.54 622.50 0.41 475.05 1160.84 1.00 General
SPLIT MN1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 369.16 1160.84 1.00 General
SPLIT MN2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 367.74 1160.84 1.00 General
SPLIT MS1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 363.86 1160.84 1.00 General
SPLIT MS2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 364.72 1160.84 1.00 General
SPLIT TSW SUPPLY FAN Fan:OnOff 0.54 622.50 0.35 411.74 1160.84 1.00 General
SPLIT TNW SUPPLY FAN Fan:OnOff 0.54 622.50 0.35 401.55 1160.84 1.00 General
SPLIT TSE SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 375.66 1160.84 1.00 General
SPLIT TNE SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 352.86 1160.84 1.00 General
SPLIT TN1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 279.60 1160.84 1.00 General
SPLIT TN2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 279.59 1160.84 1.00 General
SPLIT TS1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 301.14 1160.84 1.00 General
SPLIT TS2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.26 301.58 1160.84 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
None              


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
G SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M SE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T SE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:31

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1805.78 2166.94 0.163 0.196 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 16:45:00 36.54 0.00682
G NW APARTMENT 1792.23 2150.68 0.162 0.194 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 35.63 0.00682
OFFICE 4629.50 5555.40 0.439 0.527 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 09:30:00 32.05 0.00682
G NE APARTMENT 1435.60 1722.72 0.130 0.156 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 34.98 0.00682
G N1 APARTMENT 1125.25 1350.30 0.102 0.122 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 34.49 0.00682
G N2 APARTMENT 1118.23 1341.88 0.101 0.121 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 34.49 0.00682
G S1 APARTMENT 1100.53 1320.64 0.099 0.119 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 34.98 0.00682
G S2 APARTMENT 1115.92 1339.10 0.101 0.121 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 37.94 0.00682
M SW APARTMENT 4587.08 5504.50 0.414 0.497 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 16:45:00 36.54 0.00682
M NW APARTMENT 4549.91 5459.90 0.411 0.493 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 17:30:00 35.63 0.00682
M SE APARTMENT 4006.28 4807.53 0.362 0.434 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 37.94 0.00682
M NE APARTMENT 3776.94 4532.33 0.341 0.409 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 34.98 0.00682
M N1 APARTMENT 2935.02 3522.03 0.265 0.318 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 34.98 0.00682
M N2 APARTMENT 2923.73 3508.48 0.264 0.317 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 34.98 0.00682
M S1 APARTMENT 2892.86 3471.44 0.261 0.313 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
M S2 APARTMENT 2899.76 3479.71 0.262 0.314 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
T SW APARTMENT 3273.61 3928.33 0.296 0.355 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:45:00 37.52 0.00682
T NW APARTMENT 3192.61 3831.13 0.288 0.346 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 36.80 0.00682
T SE APARTMENT 2986.74 3584.09 0.270 0.324 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 38.10 0.00682
T NE APARTMENT 2805.48 3366.58 0.253 0.304 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 38.10 0.00682
T N1 APARTMENT 2222.99 2667.59 0.201 0.241 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:15:00 37.91 0.00682
T N2 APARTMENT 2222.93 2667.52 0.201 0.241 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:45:00 38.10 0.00682
T S1 APARTMENT 2394.27 2873.13 0.216 0.259 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 38.10 0.00682
T S2 APARTMENT 2397.75 2877.30 0.216 0.260 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 38.10 0.00682


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1003.63 1204.35 0.033 0.040 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.20 0.00281
G NW APARTMENT 1011.18 1213.41 0.034 0.040 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.20 0.00281
OFFICE 2195.55 2634.66 0.070 0.084 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.20 0.00281
G NE APARTMENT 1015.18 1218.22 0.034 0.040 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.20 0.00281
G N1 APARTMENT 582.26 698.72 0.019 0.026 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.20 0.00281
G N2 APARTMENT 582.36 698.84 0.019 0.026 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.20 0.00281
G S1 APARTMENT 576.16 691.40 0.019 0.026 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.20 0.00281
G S2 APARTMENT 652.84 783.41 0.022 0.026 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -5.20 0.00281
M SW APARTMENT 1923.30 2307.97 0.064 0.077 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.20 0.00281
M NW APARTMENT 1942.08 2330.50 0.064 0.077 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.20 0.00281
M SE APARTMENT 1934.18 2321.02 0.064 0.077 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.20 0.00281
M NE APARTMENT 1952.95 2343.54 0.065 0.078 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.20 0.00281
M N1 APARTMENT 872.05 1046.46 0.029 0.052 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.20 0.00281
M N2 APARTMENT 872.35 1046.82 0.029 0.052 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.20 0.00281
M S1 APARTMENT 854.63 1025.56 0.028 0.052 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.20 0.00281
M S2 APARTMENT 854.93 1025.91 0.028 0.052 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.20 0.00281
T SW APARTMENT 1893.73 2272.48 0.063 0.075 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.20 0.00281
T NW APARTMENT 1904.87 2285.84 0.063 0.076 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.20 0.00281
T SE APARTMENT 1899.45 2279.34 0.063 0.076 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.20 0.00281
T NE APARTMENT 1910.59 2292.70 0.063 0.076 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.20 0.00281
T N1 APARTMENT 1343.04 1611.65 0.045 0.053 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.20 0.00281
T N2 APARTMENT 1343.21 1611.85 0.045 0.053 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.20 0.00281
T S1 APARTMENT 1330.23 1596.28 0.044 0.053 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.20 0.00281
T S2 APARTMENT 1330.40 1596.48 0.044 0.053 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -5.20 0.00281


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
SPLIT GSW 0.20 0.20 0.04 0.04
SPLIT GNW 0.19 0.19 0.04 0.04
SPLIT OFFICE 0.53 0.53 0.08 0.08
SPLIT GNE 0.16 0.16 0.04 0.04
SPLIT GN1 0.12 0.12 0.03 0.03
SPLIT GN2 0.12 0.12 0.03 0.03
SPLIT GS1 0.12 0.12 0.03 0.03
SPLIT GS2 0.12 0.12 0.03 0.03
SPLIT MSW 0.50 0.50 0.08 0.08
SPLIT MNW 0.49 0.49 0.08 0.08
SPLIT MSE 0.43 0.43 0.08 0.08
SPLIT MNE 0.41 0.41 0.08 0.08
SPLIT MN1 0.32 0.32 0.05 0.05
SPLIT MN2 0.32 0.32 0.05 0.05
SPLIT MS1 0.31 0.31 0.05 0.05
SPLIT MS2 0.31 0.31 0.05 0.05
SPLIT TSW 0.35 0.35 0.08 0.08
SPLIT TNW 0.35 0.35 0.08 0.08
SPLIT TSE 0.32 0.32 0.08 0.08
SPLIT TNE 0.30 0.30 0.08 0.08
SPLIT TN1 0.24 0.24 0.05 0.05
SPLIT TN2 0.24 0.24 0.05 0.05
SPLIT TS1 0.26 0.26 0.05 0.05
SPLIT TS2 0.26 0.26 0.05 0.05



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:31

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 2723.00 5348.75 325.25
G NW APARTMENT 2811.25 5618.75 548.75
OFFICE 703.00 1237.00 0.25
G NE APARTMENT 2803.50 5645.00 566.75
G N1 APARTMENT 2473.25 5872.25 500.75
G N2 APARTMENT 2475.75 5873.00 504.75
G S1 APARTMENT 2455.50 5635.00 326.25
G S2 APARTMENT 2515.00 5496.00 251.75
M SW APARTMENT 3479.25 2699.25 107.75
M NW APARTMENT 3215.75 3843.00 120.50
M SE APARTMENT 3436.75 2705.75 111.50
M NE APARTMENT 3202.75 3865.00 135.00
M N1 APARTMENT 2998.25 3868.25 133.50
M N2 APARTMENT 2996.50 3869.75 134.00
M S1 APARTMENT 3265.00 2227.50 112.50
M S2 APARTMENT 3264.25 2231.00 112.50
T SW APARTMENT 3867.00 3580.25 355.50
T NW APARTMENT 3840.00 4284.00 610.25
T SE APARTMENT 3865.25 3549.50 369.00
T NE APARTMENT 3846.25 4304.50 616.00
T N1 APARTMENT 3527.25 4372.00 447.00
T N2 APARTMENT 3528.25 4365.25 450.50
T S1 APARTMENT 3594.75 3476.75 225.00
T S2 APARTMENT 3594.25 3473.75 224.75
T CORRIDOR 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
Facility 4547.25 5914.25 878.75
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 6.00 0.00 6.00 0.00
G NW APARTMENT 0.75 0.75 0.75 0.75
OFFICE 0.00 21.25 0.00 0.00
G NE APARTMENT 3.75 0.00 3.75 0.00
G N1 APARTMENT 10.25 0.50 10.25 0.50
G N2 APARTMENT 10.00 0.25 10.00 0.25
G S1 APARTMENT 2.50 0.00 2.50 0.00
G S2 APARTMENT 3.00 0.00 3.00 0.00
M SW APARTMENT 0.25 0.00 0.25 0.00
M NW APARTMENT 0.75 0.00 0.75 0.00
M SE APARTMENT 0.25 0.00 0.25 0.00
M NE APARTMENT 1.00 0.00 1.00 0.00
M N1 APARTMENT 0.00 0.00 0.00 0.00
M N2 APARTMENT 0.00 0.00 0.00 0.00
M S1 APARTMENT 0.00 0.00 0.00 0.00
M S2 APARTMENT 0.00 0.00 0.00 0.00
T SW APARTMENT 0.00 0.50 0.00 0.50
T NW APARTMENT 0.00 1.25 0.00 1.25
T SE APARTMENT 0.00 0.00 0.00 0.00
T NE APARTMENT 0.00 0.25 0.00 0.25
T N1 APARTMENT 0.50 0.00 0.50 0.00
T N2 APARTMENT 0.25 0.00 0.25 0.00
T S1 APARTMENT 0.25 0.00 0.25 0.00
T S2 APARTMENT 0.00 0.00 0.00 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
Facility 34.25 24.75 34.25 3.50
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:31

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.97 0.366 0.163 0.000 0.085
G NW APARTMENT 1.71 2.50 268.97 0.353 0.163 0.000 0.081
OFFICE 0.94 1.00 268.97 0.518 0.176 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.353 0.163 0.000 0.081
G N1 APARTMENT 1.71 2.50 268.97 0.353 0.098 0.000 0.080
G N2 APARTMENT 1.71 2.50 268.97 0.353 0.098 0.000 0.080
G S1 APARTMENT 1.71 2.50 268.97 0.353 0.098 0.000 0.084
G S2 APARTMENT 1.71 2.50 268.97 0.353 0.098 0.000 0.084
M SW APARTMENT 1.71 2.50 268.97 0.354 0.235 0.000 0.105
M NW APARTMENT 1.71 2.50 268.97 0.354 0.235 0.000 0.102
M SE APARTMENT 1.71 2.50 268.97 0.354 0.235 0.000 0.105
M NE APARTMENT 1.71 2.50 268.97 0.354 0.235 0.000 0.102
M N1 APARTMENT 1.71 2.50 268.97 0.354 0.142 0.000 0.102
M N2 APARTMENT 1.71 2.50 268.97 0.354 0.142 0.000 0.102
M S1 APARTMENT 1.71 2.50 268.97 0.354 0.142 0.000 0.105
M S2 APARTMENT 1.71 2.50 268.97 0.354 0.142 0.000 0.105
T SW APARTMENT 1.71 2.50 268.97 0.354 0.311 0.000 0.126
T NW APARTMENT 1.71 2.50 268.97 0.353 0.310 0.000 0.122
T SE APARTMENT 1.71 2.50 268.97 0.354 0.311 0.000 0.126
T NE APARTMENT 1.71 2.50 268.97 0.353 0.310 0.000 0.123
T N1 APARTMENT 1.71 2.50 268.97 0.353 0.187 0.000 0.122
T N2 APARTMENT 1.71 2.50 268.97 0.353 0.187 0.000 0.122
T S1 APARTMENT 1.71 2.50 268.97 0.354 0.187 0.000 0.126
T S2 APARTMENT 1.71 2.50 268.97 0.354 0.187 0.000 0.126
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.97 0.356 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
OFFICE 0.94 1.00 268.97 0.505 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.97 1.378 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.97 1.373 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.97 1.377 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.97 1.373 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.97 1.374 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 1.374 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.97 1.381 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 1.381 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.343 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:31

Surfaces by Class

Total Outdoors
Wall 126 42
Floor 27 9
Roof 27 9
Internal Mass 24 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 39 39
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 24
Conditioned Zones 24
Unconditioned Zones 3
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 1385
Defaulted Fields 439
Fields with Defaults 3704
Autosized Fields 336
Autosizable Fields 454
Autocalculated Fields 247
Autocalculatable Fields 424



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2015-09-09 18:47:31

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 1472.34 21215.72 01-JAN-03:15 83900.92 26-JUL-17:45
Electricity:Building 636.11 10559.61 01-JAN-03:15 31610.87 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity 118.46 2466.75 01-JAN-00:15 5482.59 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 96.36 2205.67 01-JAN-00:15 4426.44 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:OFFICE 35.93 610.39 01-JAN-00:15 2669.36 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 26.45 416.15 01-JAN-00:15 2080.74 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M SW APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:T SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G CORRIDOR 144.16 1427.03 01-JAN-00:15 8651.76 01-JAN-07:15
InteriorLights:Electricity:Zone:G CORRIDOR 14.58 462.39 01-JAN-00:15 462.39 01-JAN-00:15
Electricity:Zone:M CORRIDOR 29.16 924.77 01-JAN-00:15 924.77 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 29.16 924.77 01-JAN-00:15 924.77 01-JAN-00:15
Electricity:Zone:T CORRIDOR 14.58 462.39 01-JAN-00:15 462.39 01-JAN-00:15
InteriorLights:Electricity:Zone:T CORRIDOR 14.58 462.39 01-JAN-00:15 462.39 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 22.11 261.08 01-JAN-00:15 1411.40 02-JAN-16:15
InteriorEquipment:Electricity 517.65 8092.87 01-JAN-03:15 26730.99 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 517.65 8092.87 01-JAN-03:15 26730.99 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 9.48 194.25 01-JAN-00:15 588.62 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G CORRIDOR 129.57 964.65 01-JAN-00:15 8189.37 01-JAN-07:15
Electricity:Plant 347.53 0.00 01-JAN-00:15 30806.68 01-MAR-07:30
WaterSystems:Electricity 347.53 0.00 01-JAN-00:15 30806.68 01-MAR-07:30
Water Heater:WaterSystems:Electricity 347.53 0.00 01-JAN-00:15 30806.68 01-MAR-07:30
Fans:Electricity 255.54 8103.11 01-JAN-07:15 8103.11 01-JAN-18:30
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 1472.34 21215.72 01-JAN-03:15 83900.92 26-JUL-17:45
ElectricityPurchased:Plant 1472.34 21215.72 01-JAN-03:15 83900.92 26-JUL-17:45
Cogeneration:ElectricityPurchased 1472.34 21215.72 01-JAN-03:15 83900.92 26-JUL-17:45
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 1472.34 21215.72 01-JAN-03:15 83900.92 26-JUL-17:45
ElectricityNet:Plant 1472.34 21215.72 01-JAN-03:15 83900.92 26-JUL-17:45
Cogeneration:ElectricityNet 1472.34 21215.72 01-JAN-03:15 83900.92 26-JUL-17:45
ExteriorLights:Electricity 40.15 0.00 01-JAN-07:15 2553.00 01-JAN-00:15
General:ExteriorLights:Electricity 40.15 0.00 01-JAN-07:15 2553.00 01-JAN-00:15
Electricity:HVAC 448.54 8103.11 01-JAN-07:15 32991.26 15-JUN-15:30
General:Fans:Electricity 255.54 8103.11 01-JAN-07:15 8103.11 01-JAN-18:30
Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:Electricity 193.00 0.00 01-JAN-00:15 24888.16 15-JUN-15:30


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 49.22 0.00 01-JAN-11:00 38020.19 28-JAN-06:00
Gas:HVAC 49.22 0.00 01-JAN-11:00 38020.19 28-JAN-06:00
Heating:Gas 49.22 0.00 01-JAN-11:00 38020.19 28-JAN-06:00


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
None          


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water:Plant 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
WaterSystems:Water 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
MainsWater:Facility 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
MainsWater:Plant 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
WaterSystems:MainsWater 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
PlantLoopHeatingDemand:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 1410.22 1461.72 04-MAY-06:00 155655.67 15-JUN-17:00
EnergyTransfer:Building 622.44 1461.72 04-MAY-06:00 68126.79 15-JUN-17:00
EnergyTransfer:Zone:G SW APARTMENT 12.71 0.01 26-APR-21:45 2069.71 15-JUN-17:00
Heating:EnergyTransfer 31.86 0.00 04-JAN-21:00 20788.76 26-JAN-00:15
Heating:EnergyTransfer:Zone:G SW APARTMENT 0.89 0.00 01-JAN-00:15 917.01 09-FEB-01:00
Cooling:EnergyTransfer 590.58 0.00 03-MAR-19:15 68126.79 15-JUN-17:00
Cooling:EnergyTransfer:Zone:G SW APARTMENT 11.82 0.00 01-JAN-03:45 2069.71 15-JUN-17:00
EnergyTransfer:Zone:G NW APARTMENT 11.55 0.01 25-MAY-04:15 2159.96 15-JUN-17:15
Heating:EnergyTransfer:Zone:G NW APARTMENT 2.07 0.00 01-JAN-09:00 1084.49 09-FEB-01:00
Cooling:EnergyTransfer:Zone:G NW APARTMENT 9.47 0.00 01-JAN-00:15 2159.96 15-JUN-17:15
EnergyTransfer:Zone:OFFICE 30.39 0.01 18-APR-02:15 4528.15 27-AUG-10:30
Heating:EnergyTransfer:Zone:OFFICE 5.71 0.00 01-JAN-00:30 909.01 05-JUN-17:45
Cooling:EnergyTransfer:Zone:OFFICE 24.69 0.00 01-JAN-00:15 4528.15 27-AUG-10:30
EnergyTransfer:Zone:G NE APARTMENT 11.46 0.01 14-APR-20:30 1647.77 15-JUN-17:15
Heating:EnergyTransfer:Zone:G NE APARTMENT 1.83 0.00 01-JAN-09:00 1087.57 09-FEB-01:00
Cooling:EnergyTransfer:Zone:G NE APARTMENT 9.63 0.00 01-JAN-00:15 1647.77 15-JUN-17:15
EnergyTransfer:Zone:G N1 APARTMENT 8.24 0.01 09-APR-09:00 1260.71 15-JUN-17:30
Heating:EnergyTransfer:Zone:G N1 APARTMENT 0.79 0.00 01-JAN-07:15 566.33 09-FEB-01:00
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 7.45 0.00 01-JAN-00:15 1260.71 15-JUN-17:30
EnergyTransfer:Zone:G N2 APARTMENT 8.24 0.01 03-APR-04:30 1251.69 15-JUN-17:30
Heating:EnergyTransfer:Zone:G N2 APARTMENT 0.79 0.00 01-JAN-07:15 566.03 09-FEB-01:00
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 7.45 0.00 01-JAN-00:15 1251.69 15-JUN-17:30
EnergyTransfer:Zone:G S1 APARTMENT 10.26 0.01 14-NOV-17:45 1399.27 19-SEP-13:30
Heating:EnergyTransfer:Zone:G S1 APARTMENT 0.19 0.00 01-JAN-00:15 413.92 26-JAN-00:15
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 10.07 0.00 03-JAN-13:30 1399.27 19-SEP-13:30
EnergyTransfer:Zone:G S2 APARTMENT 10.90 0.02 16-JAN-06:45 1417.33 19-SEP-13:30
Heating:EnergyTransfer:Zone:G S2 APARTMENT 0.18 0.00 01-JAN-00:15 409.40 26-JAN-00:15
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 10.72 0.00 03-JAN-13:30 1417.33 19-SEP-13:30
EnergyTransfer:Zone:M SW APARTMENT 49.64 0.20 11-DEC-10:30 5428.33 15-JUN-17:00
Heating:EnergyTransfer:Zone:M SW APARTMENT 0.06 0.00 01-JAN-00:15 811.46 26-JAN-00:15
Cooling:EnergyTransfer:Zone:M SW APARTMENT 49.58 0.00 03-JAN-19:00 5428.33 15-JUN-17:00
EnergyTransfer:Zone:M NW APARTMENT 38.30 0.06 25-MAR-23:15 5623.05 15-JUN-17:15
Heating:EnergyTransfer:Zone:M NW APARTMENT 0.75 0.00 01-JAN-00:15 1717.02 26-JAN-00:15
Cooling:EnergyTransfer:Zone:M NW APARTMENT 37.56 0.00 01-JAN-12:00 5623.05 15-JUN-17:15
EnergyTransfer:Zone:M SE APARTMENT 50.11 0.54 24-MAR-15:30 4536.84 19-SEP-13:00
Heating:EnergyTransfer:Zone:M SE APARTMENT 0.05 0.00 01-JAN-00:15 829.19 26-JAN-00:15
Cooling:EnergyTransfer:Zone:M SE APARTMENT 50.05 0.00 03-JAN-19:00 4536.84 19-SEP-13:00
EnergyTransfer:Zone:M NE APARTMENT 38.96 0.11 17-NOV-13:45 4525.67 15-JUN-17:00
Heating:EnergyTransfer:Zone:M NE APARTMENT 0.70 0.00 01-JAN-00:15 1722.56 26-JAN-00:15
Cooling:EnergyTransfer:Zone:M NE APARTMENT 38.27 0.00 01-JAN-13:00 4525.67 15-JUN-17:00
EnergyTransfer:Zone:M N1 APARTMENT 33.18 0.00 13-JAN-13:45 3436.48 15-JUN-17:15
Heating:EnergyTransfer:Zone:M N1 APARTMENT 0.06 0.00 01-JAN-00:15 503.16 30-DEC-06:45
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 33.12 0.00 02-JAN-12:30 3436.48 15-JUN-17:15
EnergyTransfer:Zone:M N2 APARTMENT 33.18 0.04 18-FEB-13:00 3421.18 15-JUN-17:15
Heating:EnergyTransfer:Zone:M N2 APARTMENT 0.06 0.00 01-JAN-00:15 445.84 28-JAN-06:00
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 33.12 0.00 02-JAN-12:30 3421.18 15-JUN-17:15
EnergyTransfer:Zone:M S1 APARTMENT 46.01 1.14 14-FEB-17:00 3721.33 18-OCT-13:30
Heating:EnergyTransfer:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 54.74 10-NOV-06:15
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 46.01 0.00 14-FEB-17:00 3721.33 18-OCT-13:30
EnergyTransfer:Zone:M S2 APARTMENT 46.01 2.89 10-NOV-07:15 3726.27 18-OCT-13:30
Heating:EnergyTransfer:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 55.74 10-NOV-06:15
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 46.01 0.00 14-FEB-17:00 3726.27 18-OCT-13:30
EnergyTransfer:Zone:T SW APARTMENT 27.09 0.01 09-OCT-02:15 3758.07 15-JUN-16:30
Heating:EnergyTransfer:Zone:T SW APARTMENT 2.47 0.00 01-JAN-08:30 1918.51 09-FEB-01:00
Cooling:EnergyTransfer:Zone:T SW APARTMENT 24.61 0.00 01-JAN-00:15 3758.07 15-JUN-16:30
EnergyTransfer:Zone:T NW APARTMENT 24.13 0.01 04-JAN-21:00 3839.29 15-JUN-17:00
Heating:EnergyTransfer:Zone:T NW APARTMENT 4.14 0.00 01-JAN-21:45 2114.51 09-FEB-01:00
Cooling:EnergyTransfer:Zone:T NW APARTMENT 19.99 0.00 01-JAN-00:15 3839.29 15-JUN-17:00
EnergyTransfer:Zone:T SE APARTMENT 26.84 0.03 23-OCT-19:45 3158.41 21-JUN-13:00
Heating:EnergyTransfer:Zone:T SE APARTMENT 2.29 0.00 01-JAN-00:45 1942.37 09-FEB-01:00
Cooling:EnergyTransfer:Zone:T SE APARTMENT 24.55 0.00 01-JAN-00:15 3158.41 21-JUN-13:00
EnergyTransfer:Zone:T NE APARTMENT 23.70 0.01 16-NOV-21:30 3129.56 15-JUN-16:30
Heating:EnergyTransfer:Zone:T NE APARTMENT 3.79 0.00 01-JAN-09:00 2122.11 09-FEB-01:00
Cooling:EnergyTransfer:Zone:T NE APARTMENT 19.91 0.00 01-JAN-00:15 3129.56 15-JUN-16:30
EnergyTransfer:Zone:T N1 APARTMENT 18.34 0.00 01-NOV-12:45 2546.55 15-JUN-17:00
Heating:EnergyTransfer:Zone:T N1 APARTMENT 1.78 0.00 01-JAN-00:15 1175.95 09-FEB-01:00
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 16.56 0.00 01-JAN-01:00 2546.55 15-JUN-17:00
EnergyTransfer:Zone:T N2 APARTMENT 18.36 0.02 03-JAN-22:00 2530.28 15-JUN-17:00
Heating:EnergyTransfer:Zone:T N2 APARTMENT 1.79 0.00 01-JAN-00:15 1175.69 09-FEB-01:00
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 16.57 0.00 01-JAN-01:00 2530.28 15-JUN-17:00
EnergyTransfer:Zone:T S1 APARTMENT 22.40 0.03 07-MAR-06:45 2704.19 19-SEP-13:30
Heating:EnergyTransfer:Zone:T S1 APARTMENT 0.74 0.00 01-JAN-00:15 1020.70 27-DEC-06:00
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 21.67 0.00 02-JAN-05:30 2704.19 19-SEP-13:30
EnergyTransfer:Zone:T S2 APARTMENT 22.43 0.02 16-JAN-16:00 2709.40 19-SEP-13:30
Heating:EnergyTransfer:Zone:T S2 APARTMENT 0.74 0.00 01-JAN-00:15 1021.02 27-DEC-06:00
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 21.69 0.00 02-JAN-05:30 2709.40 19-SEP-13:30
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:HVAC 787.78 0.00 14-FEB-17:45 87686.84 05-JUN-17:00
HeatingCoils:EnergyTransfer 39.38 0.00 01-JAN-11:00 30416.15 28-JAN-06:00
CoolingCoils:EnergyTransfer 748.40 0.00 01-JAN-00:15 87686.84 05-JUN-17:00



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:31

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 0.892 -11.819 0.000 0.000 3.722 1.087 12.213 15.377 0.000 0.622 0.001 0.000 -4.857 0.000 -3.268 -13.968
G NW APARTMENT 2.071 -9.475 0.000 0.000 3.761 1.087 12.213 8.788 0.000 0.621 0.000 0.000 -4.931 0.000 -3.054 -11.080
OFFICE 5.707 -24.687 0.000 0.000 0.518 26.452 9.482 14.951 0.000 0.357 0.000 0.000 -5.282 0.000 -2.896 -24.602
G NE APARTMENT 1.832 -9.625 0.000 0.000 3.772 1.087 12.213 8.669 0.000 0.621 0.000 0.000 -4.691 0.000 -3.031 -10.846
G N1 APARTMENT 0.789 -7.451 0.000 0.000 3.773 1.087 12.213 3.183 0.000 0.392 0.000 0.000 -3.007 0.000 -2.037 -8.942
G N2 APARTMENT 0.789 -7.454 0.000 0.000 3.774 1.087 12.213 3.182 0.000 0.392 0.000 0.000 -3.005 0.000 -2.036 -8.940
G S1 APARTMENT 0.186 -10.070 0.000 0.000 3.724 1.087 12.213 9.846 0.000 0.391 0.000 0.000 -2.930 0.000 -2.255 -12.193
G S2 APARTMENT 0.179 -10.722 0.000 0.000 3.721 1.087 12.213 9.833 0.000 0.391 0.000 0.000 -2.941 0.000 -2.265 -11.496
M SW APARTMENT 0.058 -49.584 0.000 0.000 3.580 1.087 12.213 14.762 0.000 0.885 27.454 0.000 -5.546 0.000 -4.908 0.000
M NW APARTMENT 0.748 -37.556 0.000 0.000 3.644 1.087 12.213 8.308 0.000 0.883 20.966 0.000 -5.592 0.000 -4.700 0.000
M SE APARTMENT 0.052 -50.054 0.000 0.000 3.586 1.087 12.213 14.747 0.000 0.885 27.802 0.000 -5.416 0.000 -4.902 0.000
M NE APARTMENT 0.699 -38.266 0.000 0.000 3.656 1.087 12.213 8.167 0.000 0.883 21.547 0.000 -5.314 0.000 -4.671 0.000
M N1 APARTMENT 0.059 -33.124 0.000 0.000 3.626 1.087 12.213 2.903 0.000 0.552 19.427 0.000 -3.507 0.000 -3.235 0.000
M N2 APARTMENT 0.059 -33.122 0.000 0.000 3.627 1.087 12.213 2.902 0.000 0.552 19.420 0.000 -3.504 0.000 -3.234 0.000
M S1 APARTMENT 0.000 -46.008 0.000 0.000 3.555 1.087 12.213 9.445 0.000 0.554 25.923 0.000 -3.379 0.000 -3.390 0.000
M S2 APARTMENT 0.000 -46.011 0.000 0.000 3.555 1.087 12.213 9.445 0.000 0.554 25.925 0.000 -3.379 0.000 -3.390 0.000
T SW APARTMENT 2.472 -24.613 0.000 0.000 3.662 1.087 12.213 14.524 0.000 1.167 0.716 0.000 -5.158 0.000 -6.070 -0.000
T NW APARTMENT 4.140 -19.990 0.000 0.000 3.699 1.087 12.213 8.112 0.000 1.164 0.667 0.000 -5.233 0.000 -5.858 -0.000
T SE APARTMENT 2.290 -24.552 0.000 0.000 3.668 1.087 12.213 14.515 0.000 1.167 0.732 0.000 -5.043 0.000 -6.075 -0.001
T NE APARTMENT 3.792 -19.908 0.000 0.000 3.709 1.087 12.213 8.011 0.000 1.164 0.787 0.000 -5.007 0.000 -5.847 -0.000
T N1 APARTMENT 1.778 -16.560 0.000 0.000 3.696 1.087 12.213 2.840 0.000 0.730 1.402 0.000 -3.240 0.000 -3.945 -0.000
T N2 APARTMENT 1.789 -16.570 0.000 0.000 3.697 1.087 12.213 2.837 0.000 0.730 1.401 0.000 -3.238 0.000 -3.946 -0.000
T S1 APARTMENT 0.738 -21.665 0.000 0.000 3.647 1.087 12.213 9.317 0.000 0.733 1.217 0.000 -3.149 0.000 -4.136 -0.000
T S2 APARTMENT 0.742 -21.687 0.000 0.000 3.647 1.087 12.213 9.315 0.000 0.733 1.235 0.000 -3.148 0.000 -4.137 -0.000
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 14.582 0.000 0.205 0.000 0.087 0.000 0.000 -0.557 0.000 -0.973 -13.344
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 14.582 6.479 0.727 0.000 2.390 0.001 0.000 -1.389 0.000 -14.995 -7.794
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 14.582 0.000 0.213 0.000 0.078 0.000 0.000 -0.627 0.000 -0.820 -13.425
Total Facility 31.861 -590.571 0.000 0.000 85.019 95.189 296.854 215.124 0.000 19.676 196.623 0.000 -103.070 0.000 -110.074 -136.632


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 15-JUN-17:00 0.00 -2069.75 0.00 0.00 84.76 64.86 588.62 1664.83 0.00 335.55 0.00 0.00 0.00 0.00 0.00 -668.87
G NW APARTMENT 15-JUN-17:19 0.00 -2173.09 0.00 0.00 141.62 87.56 588.62 1841.44 0.00 273.30 0.00 0.00 0.00 0.00 0.00 -759.44
OFFICE 16-JUL-06:01 0.00 -7869.90 0.00 0.00 0.00 416.15 294.31 729.32 0.00 0.00 6463.49 0.00 0.00 0.00 -33.38 0.00
G NE APARTMENT 15-JUN-17:05 0.00 -1648.23 0.00 0.00 141.80 87.56 588.62 815.96 0.00 304.01 0.00 0.00 0.00 0.00 0.00 -289.72
G N1 APARTMENT 15-JUN-17:19 0.00 -1265.02 0.00 0.00 141.71 87.56 588.62 628.01 0.00 164.88 0.00 0.00 0.00 0.00 0.00 -345.76
G N2 APARTMENT 15-JUN-17:19 0.00 -1255.46 0.00 0.00 141.71 87.56 588.62 628.17 0.00 164.88 0.00 0.00 0.00 0.00 0.00 -355.49
G S1 APARTMENT 19-SEP-13:30 0.00 -1399.11 0.00 0.00 40.75 12.97 382.60 1513.68 0.00 58.99 0.00 0.00 0.00 0.00 0.00 -609.89
G S2 APARTMENT 19-SEP-13:30 0.00 -1417.20 0.00 0.00 40.75 12.97 382.60 1513.35 0.00 58.99 0.00 0.00 0.00 0.00 0.00 -591.47
M SW APARTMENT 15-JUN-17:00 0.00 -5428.43 0.00 0.00 84.76 64.86 588.62 1642.13 0.00 481.47 2566.59 0.00 0.00 0.00 0.00 0.00
M NW APARTMENT 15-JUN-17:03 0.00 -5625.49 0.00 0.00 141.68 87.56 588.62 1846.19 0.00 435.87 2525.57 0.00 0.00 0.00 0.00 0.00
M SE APARTMENT 19-SEP-13:00 0.00 -4536.43 0.00 0.00 40.75 12.97 388.49 1813.19 0.00 141.68 2139.35 0.00 0.00 0.00 0.00 0.00
M NE APARTMENT 15-JUN-17:00 0.00 -4525.75 0.00 0.00 84.76 64.86 588.62 803.27 0.00 481.47 2502.78 0.00 0.00 0.00 0.00 0.00
M N1 APARTMENT 15-JUN-17:15 0.00 -3436.85 0.00 0.00 141.80 87.56 588.62 602.87 0.00 263.02 1752.98 0.00 0.00 0.00 0.00 0.00
M N2 APARTMENT 15-JUN-17:15 0.00 -3421.55 0.00 0.00 141.80 87.56 588.62 602.96 0.00 263.01 1737.60 0.00 0.00 0.00 0.00 0.00
M S1 APARTMENT 18-OCT-13:30 0.00 -3720.97 0.00 0.00 40.75 12.97 382.60 1651.77 0.00 35.07 1597.80 0.00 0.00 0.00 0.00 0.00
M S2 APARTMENT 18-OCT-13:30 0.00 -3725.91 0.00 0.00 40.75 12.97 382.60 1651.74 0.00 35.07 1602.78 0.00 0.00 0.00 0.00 0.00
T SW APARTMENT 15-JUN-16:30 0.00 -3758.25 0.00 0.00 84.76 64.86 588.62 1710.41 0.00 611.33 698.27 0.00 0.00 0.00 0.00 0.00
T NW APARTMENT 15-JUN-17:00 0.00 -3839.35 0.00 0.00 84.76 64.86 588.62 1824.49 0.00 634.85 641.77 0.00 0.00 0.00 0.00 0.00
T SE APARTMENT 21-JUN-13:00 0.00 -3158.48 0.00 0.00 40.75 12.97 388.49 894.75 0.00 774.69 1046.82 0.00 0.00 0.00 0.00 0.00
T NE APARTMENT 15-JUN-16:23 0.00 -3129.67 0.00 0.00 84.76 64.86 588.62 756.15 0.00 611.33 1023.96 0.00 0.00 0.00 0.00 0.00
T N1 APARTMENT 15-JUN-17:00 0.00 -2546.60 0.00 0.00 84.76 64.86 588.62 566.47 0.00 382.94 858.96 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 15-JUN-17:00 0.00 -2530.33 0.00 0.00 84.76 64.86 588.62 566.70 0.00 382.94 842.46 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 19-SEP-13:30 0.00 -2703.96 0.00 0.00 40.75 12.97 382.60 1463.12 0.00 111.39 693.12 0.00 0.00 0.00 0.00 0.00
T S2 APARTMENT 19-SEP-13:30 0.00 -2709.17 0.00 0.00 40.75 12.97 382.60 1463.03 0.00 111.39 698.42 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 15-JUN-16:30 0.00 -68405.14 0.00 0.00 1949.38 3295.01 14242.10 20898.80 0.00 12349.17 15670.68 0.00 0.00 0.00 0.00 0.00


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 13-APR-06:01 1663.01 0.00 0.00 0.00 163.16 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -355.60 0.00 -139.00 -1756.33
G NW APARTMENT 21-FEB-07:01 1655.76 0.00 0.00 0.00 163.04 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -385.91 0.00 -68.21 -1789.44
OFFICE 20-DEC-07:01 3417.72 0.00 0.00 0.00 0.00 416.15 294.31 0.00 0.00 0.00 0.00 0.00 -490.23 0.00 -465.61 -3172.34
G NE APARTMENT 25-FEB-08:01 1468.14 0.00 0.00 0.00 74.87 19.46 388.49 596.08 0.00 0.00 0.00 0.00 0.00 0.00 -172.35 -2374.69
G N1 APARTMENT 05-MAR-07:01 966.96 0.00 0.00 0.00 161.37 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -211.41 0.00 -121.48 -1220.20
G N2 APARTMENT 05-MAR-07:01 981.88 0.00 0.00 0.00 161.37 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -211.30 0.00 -121.48 -1235.24
G S1 APARTMENT 24-DEC-07:01 1070.01 0.00 0.00 0.00 161.39 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -358.43 0.00 -167.14 -1130.59
G S2 APARTMENT 15-JAN-07:01 1246.19 0.00 0.00 0.00 163.04 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -225.42 0.00 -114.18 -1494.39
M SW APARTMENT 26-JAN-00:15 811.51 0.00 0.00 0.00 189.67 6.49 264.88 0.00 0.00 0.00 275.52 0.00 -501.09 0.00 -1046.98 0.00
M NW APARTMENT 29-DEC-07:01 3034.24 0.00 0.00 0.00 163.41 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -642.76 0.00 -61.79 -2917.87
M SE APARTMENT 26-JAN-00:15 829.24 0.00 0.00 0.00 189.67 6.49 264.88 0.00 0.00 0.00 249.00 0.00 -492.30 0.00 -1046.98 0.00
M NE APARTMENT 26-JAN-00:15 1722.66 0.00 0.00 0.00 189.67 6.49 264.88 0.00 0.00 0.00 0.00 0.00 -477.24 0.00 -1046.98 -659.47
M N1 APARTMENT 30-DEC-06:45 1006.30 0.00 0.00 0.00 189.67 45.40 317.86 0.00 0.00 0.00 0.00 0.00 -438.99 0.00 -187.38 -932.86
M N2 APARTMENT 28-JAN-06:00 445.83 0.00 0.00 0.00 189.67 42.16 253.11 0.00 0.00 0.00 0.00 0.00 -455.55 0.00 -368.29 -106.92
M S1 APARTMENT 10-NOV-06:10 62.77 0.00 0.00 0.00 162.99 45.40 317.86 0.00 0.00 0.00 506.07 0.00 -159.99 0.00 -935.09 0.00
M S2 APARTMENT 10-NOV-06:10 63.79 0.00 0.00 0.00 162.99 45.40 317.86 0.00 0.00 0.00 505.02 0.00 -159.98 0.00 -935.08 0.00
T SW APARTMENT 09-FEB-01:00 1918.42 0.00 0.00 0.00 189.67 6.49 264.88 0.00 0.00 0.00 26.98 0.00 -638.91 0.00 -1767.52 0.00
T NW APARTMENT 09-FEB-01:00 2114.41 0.00 0.00 0.00 189.67 6.49 264.88 0.00 0.00 0.00 0.00 0.00 -612.49 0.00 -1767.52 -195.43
T SE APARTMENT 09-FEB-01:00 1942.27 0.00 0.00 0.00 189.67 6.49 264.88 0.00 0.00 0.00 0.00 0.00 -627.29 0.00 -1767.52 -8.49
T NE APARTMENT 09-FEB-01:00 2121.99 0.00 0.00 0.00 189.67 6.49 264.88 0.00 0.00 0.00 0.00 0.00 -601.70 0.00 -1767.52 -213.80
T N1 APARTMENT 09-FEB-01:00 1175.92 0.00 0.00 0.00 189.67 6.49 264.88 0.00 0.00 0.00 0.00 0.00 -366.23 0.00 -1066.16 -204.57
T N2 APARTMENT 09-FEB-01:00 1175.66 0.00 0.00 0.00 189.67 6.49 264.88 0.00 0.00 0.00 0.00 0.00 -366.23 0.00 -1066.16 -204.30
T S1 APARTMENT 17-JAN-07:01 1071.70 0.00 0.00 0.00 162.27 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -269.17 0.00 0.00 -1389.56
T S2 APARTMENT 17-JAN-07:01 1078.81 0.00 0.00 0.00 162.28 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -269.12 0.00 0.00 -1396.73
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 26-JAN-00:15 19782.50 0.00 0.00 0.00 4352.66 1952.47 6334.72 0.00 0.00 0.00 0.00 0.00 -9336.63 0.00 -20838.23 -2247.49



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:31

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:31

Sec1.1A-General Information

Data
Weather File El Paso International Ap Ut TX USA TMY3 WMO#=722700
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 3134.61
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.32
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
T CORRIDOR 77.66 0.00 77.66 0.00
G CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
Totals 3134.61 2823.98 310.64  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 34.25
Number of hours cooling loads not met 3.50
Number of hours not met 37.75


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 118.46 4979.95 0.00 0.00 0.00 0.00
Exterior Lighting 40.15 0.00 0.00 0.00 0.00 0.00
Space Heating 0.00 0.00 49.22 38020.19 0.00 0.00
Space Cooling 193.00 22630.76 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Fans-Interior 255.54 8103.11 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 347.53 21556.18 0.00 0.00 0.00 0.00
Receptacle Equipment 517.65 26630.92 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 1472.34   49.22   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 517.65 1472.34
Natural Gas 0.00 49.22
Additional 0.00 0.00
Total 517.65 1521.56


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 37.79
Space Heating 0.00
Space Cooling 61.57
Fans-Interior 81.52
Service Water Heating 110.87
Receptacle Equipment 165.14
Miscellaneous 12.81
Subtotal 469.70


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 15.70
Service Water Heating 0.00
Miscellaneous 0.00
Subtotal 15.70


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 7.79
Space Heating 3.23
Space Cooling 12.68
Fans-Interior 16.79
Service Water Heating 22.84
Receptacle Equipment 34.02
Miscellaneous 2.64



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:31

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.195656
G NW APARTMENT DIRECT AIR 0.194188
OFFICE DIRECT AIR 0.526933
G NE APARTMENT DIRECT AIR 0.155548
G N1 APARTMENT DIRECT AIR 0.121922
G N2 APARTMENT DIRECT AIR 0.121161
G S1 APARTMENT DIRECT AIR 0.119244
G S2 APARTMENT DIRECT AIR 0.120910
M SW APARTMENT DIRECT AIR 0.497005
M NW APARTMENT DIRECT AIR 0.492981
M SE APARTMENT DIRECT AIR 0.434075
M NE APARTMENT DIRECT AIR 0.409232
M N1 APARTMENT DIRECT AIR 0.318011
M N2 APARTMENT DIRECT AIR 0.316788
M S1 APARTMENT DIRECT AIR 0.313442
M S2 APARTMENT DIRECT AIR 0.314189
T SW APARTMENT DIRECT AIR 0.354688
T NW APARTMENT DIRECT AIR 0.345912
T SE APARTMENT DIRECT AIR 0.323607
T NE APARTMENT DIRECT AIR 0.303968
T N1 APARTMENT DIRECT AIR 0.240860
T N2 APARTMENT DIRECT AIR 0.240853
T S1 APARTMENT DIRECT AIR 0.259418
T S2 APARTMENT DIRECT AIR 0.259795


Branch

Maximum Flow Rate [m3/s]
SPLIT GSW MAIN BRANCH 0.195656
SPLIT GNW MAIN BRANCH 0.194188
SPLIT OFFICE MAIN BRANCH 0.526933
SPLIT GNE MAIN BRANCH 0.155548
SPLIT GN1 MAIN BRANCH 0.121922
SPLIT GN2 MAIN BRANCH 0.121161
SPLIT GS1 MAIN BRANCH 0.119244
SPLIT GS2 MAIN BRANCH 0.120910
SPLIT MSW MAIN BRANCH 0.497005
SPLIT MNW MAIN BRANCH 0.492981
SPLIT MSE MAIN BRANCH 0.434075
SPLIT MNE MAIN BRANCH 0.409232
SPLIT MN1 MAIN BRANCH 0.318011
SPLIT MN2 MAIN BRANCH 0.316788
SPLIT MS1 MAIN BRANCH 0.313442
SPLIT MS2 MAIN BRANCH 0.314189
SPLIT TSW MAIN BRANCH 0.354688
SPLIT TNW MAIN BRANCH 0.345912
SPLIT TSE MAIN BRANCH 0.323607
SPLIT TNE MAIN BRANCH 0.303968
SPLIT TN1 MAIN BRANCH 0.240860
SPLIT TN2 MAIN BRANCH 0.240853
SPLIT TS1 MAIN BRANCH 0.259418
SPLIT TS2 MAIN BRANCH 0.259795


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
SPLIT GSW 0.195656
SPLIT GNW 0.194188
SPLIT OFFICE 0.526933
SPLIT GNE 0.155548
SPLIT GN1 0.121922
SPLIT GN2 0.121161
SPLIT GS1 0.119244
SPLIT GS2 0.120910
SPLIT MSW 0.497005
SPLIT MNW 0.492981
SPLIT MSE 0.434075
SPLIT MNE 0.409232
SPLIT MN1 0.318011
SPLIT MN2 0.316788
SPLIT MS1 0.313442
SPLIT MS2 0.314189
SPLIT TSW 0.354688
SPLIT TNW 0.345912
SPLIT TSE 0.323607
SPLIT TNE 0.303968
SPLIT TN1 0.240860
SPLIT TN2 0.240853
SPLIT TS1 0.259418
SPLIT TS2 0.259795


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
SPLIT GSW OA CONTROLLER 0.195656 0.026898
SPLIT GNW OA CONTROLLER 0.194188 0.025953
SPLIT OFFICE OA CONTROLLER 0.526933 0.038104
SPLIT GNE OA CONTROLLER 0.155548 0.025953
SPLIT GN1 OA CONTROLLER 0.121922 0.025953
SPLIT GN2 OA CONTROLLER 0.121161 0.025953
SPLIT GS1 OA CONTROLLER 0.119244 0.025953
SPLIT GS2 OA CONTROLLER 0.120910 0.025953
SPLIT MSW OA CONTROLLER 0.497005 0.051906
SPLIT MNW OA CONTROLLER 0.492981 0.051906
SPLIT MSE OA CONTROLLER 0.434075 0.051906
SPLIT MNE OA CONTROLLER 0.409232 0.051906
SPLIT MN1 OA CONTROLLER 0.318011 0.051906
SPLIT MN2 OA CONTROLLER 0.316788 0.051906
SPLIT MS1 OA CONTROLLER 0.313442 0.051906
SPLIT MS2 OA CONTROLLER 0.314189 0.051906
SPLIT TSW OA CONTROLLER 0.354688 0.025953
SPLIT TNW OA CONTROLLER 0.345912 0.025953
SPLIT TSE OA CONTROLLER 0.323607 0.025953
SPLIT TNE OA CONTROLLER 0.303968 0.025953
SPLIT TN1 OA CONTROLLER 0.240860 0.025953
SPLIT TN2 OA CONTROLLER 0.240853 0.025953
SPLIT TS1 OA CONTROLLER 0.259418 0.025953
SPLIT TS2 OA CONTROLLER 0.259795 0.025953


Coil:Cooling:DX:SingleSpeed

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity (gross) [W] Rated Sensible Heat Ratio
SPLIT GSW COOLING COIL 0.195656 3238.79 0.798655
SPLIT GNW COOLING COIL 0.194188 3214.51 0.798655
SPLIT OFFICE COOLING COIL 0.526933 8722.60 0.798655
SPLIT GNE COOLING COIL 0.155548 2574.86 0.798655
SPLIT GN1 COOLING COIL 0.121922 2018.24 0.798655
SPLIT GN2 COOLING COIL 0.121161 2005.65 0.798655
SPLIT GS1 COOLING COIL 0.119244 1973.91 0.798655
SPLIT GS2 COOLING COIL 0.120910 2099.96 0.781416
SPLIT MSW COOLING COIL 0.497005 8227.20 0.798655
SPLIT MNW COOLING COIL 0.492981 8160.59 0.798655
SPLIT MSE COOLING COIL 0.434075 7185.49 0.798655
SPLIT MNE COOLING COIL 0.409232 6774.24 0.798655
SPLIT MN1 COOLING COIL 0.318011 5264.22 0.798655
SPLIT MN2 COOLING COIL 0.316788 5243.97 0.798655
SPLIT MS1 COOLING COIL 0.313442 5294.44 0.791304
SPLIT MS2 COOLING COIL 0.314189 5305.85 0.791386
SPLIT TSW COOLING COIL 0.354688 5871.35 0.798655
SPLIT TNW COOLING COIL 0.345912 5726.07 0.798655
SPLIT TSE COOLING COIL 0.323607 5356.85 0.798655
SPLIT TNE COOLING COIL 0.303968 5031.75 0.798655
SPLIT TN1 COOLING COIL 0.240860 3987.09 0.798655
SPLIT TN2 COOLING COIL 0.240853 3986.98 0.798655
SPLIT TS1 COOLING COIL 0.259418 4294.29 0.798655
SPLIT TS2 COOLING COIL 0.259795 4300.53 0.798655


AirLoopHVAC:Unitary:Furnace:HeatCool

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
SPLIT GSW FURNACE WITH DX COOLING 0.195656 0.195656 0.195656 0.195656 1946.11 3238.79 1.00
SPLIT GNW FURNACE WITH DX COOLING 0.194188 0.194188 0.194188 0.194188 1928.35 3214.51 1.00
SPLIT OFFICE FURNACE WITH DX COOLING 0.526933 0.526933 0.526933 0.526933 3616.86 8722.60 1.00
SPLIT GNE FURNACE WITH DX COOLING 0.155548 0.155548 0.155548 0.155548 1933.09 2574.86 1.00
SPLIT GN1 FURNACE WITH DX COOLING 0.121922 0.121922 0.121922 0.121922 1503.38 2018.24 1.00
SPLIT GN2 FURNACE WITH DX COOLING 0.121161 0.121161 0.121161 0.121161 1503.38 2005.65 1.00
SPLIT GS1 FURNACE WITH DX COOLING 0.119244 0.119244 0.119244 0.119244 1503.38 1973.91 1.00
SPLIT GS2 FURNACE WITH DX COOLING 0.120910 0.120910 0.120910 0.120910 1504.62 2099.96 1.00
SPLIT MSW FURNACE WITH DX COOLING 0.497005 0.497005 0.497005 0.497005 3739.52 8227.20 1.00
SPLIT MNW FURNACE WITH DX COOLING 0.492981 0.492981 0.492981 0.492981 3761.73 8160.59 1.00
SPLIT MSE FURNACE WITH DX COOLING 0.434075 0.434075 0.434075 0.434075 3752.38 7185.49 1.00
SPLIT MNE FURNACE WITH DX COOLING 0.409232 0.409232 0.409232 0.409232 3774.58 6774.24 1.00
SPLIT MN1 FURNACE WITH DX COOLING 0.318011 0.318011 0.318011 0.318011 3006.76 5264.22 1.00
SPLIT MN2 FURNACE WITH DX COOLING 0.316788 0.316788 0.316788 0.316788 3006.76 5243.97 1.00
SPLIT MS1 FURNACE WITH DX COOLING 0.313442 0.313442 0.313442 0.313442 3006.76 5294.44 1.00
SPLIT MS2 FURNACE WITH DX COOLING 0.314189 0.314189 0.314189 0.314189 3006.76 5305.85 1.00
SPLIT TSW FURNACE WITH DX COOLING 0.354688 0.354688 0.354688 0.354688 2971.95 5871.35 1.00
SPLIT TNW FURNACE WITH DX COOLING 0.345912 0.345912 0.345912 0.345912 2985.12 5726.07 1.00
SPLIT TSE FURNACE WITH DX COOLING 0.323607 0.323607 0.323607 0.323607 2978.70 5356.85 1.00
SPLIT TNE FURNACE WITH DX COOLING 0.303968 0.303968 0.303968 0.303968 2991.88 5031.75 1.00
SPLIT TN1 FURNACE WITH DX COOLING 0.240860 0.240860 0.240860 0.240860 2320.77 3987.09 1.00
SPLIT TN2 FURNACE WITH DX COOLING 0.240853 0.240853 0.240853 0.240853 2320.96 3986.98 1.00
SPLIT TS1 FURNACE WITH DX COOLING 0.259418 0.259418 0.259418 0.259418 2305.62 4294.29 1.00
SPLIT TS2 FURNACE WITH DX COOLING 0.259795 0.259795 0.259795 0.259795 2305.82 4300.53 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
SPLIT GSW SUPPLY FAN 0.195656
SPLIT GNW SUPPLY FAN 0.194188
SPLIT OFFICE SUPPLY FAN 0.526933
SPLIT GNE SUPPLY FAN 0.155548
SPLIT GN1 SUPPLY FAN 0.121922
SPLIT GN2 SUPPLY FAN 0.121161
SPLIT GS1 SUPPLY FAN 0.119244
SPLIT GS2 SUPPLY FAN 0.120910
SPLIT MSW SUPPLY FAN 0.497005
SPLIT MNW SUPPLY FAN 0.492981
SPLIT MSE SUPPLY FAN 0.434075
SPLIT MNE SUPPLY FAN 0.409232
SPLIT MN1 SUPPLY FAN 0.318011
SPLIT MN2 SUPPLY FAN 0.316788
SPLIT MS1 SUPPLY FAN 0.313442
SPLIT MS2 SUPPLY FAN 0.314189
SPLIT TSW SUPPLY FAN 0.354688
SPLIT TNW SUPPLY FAN 0.345912
SPLIT TSE SUPPLY FAN 0.323607
SPLIT TNE SUPPLY FAN 0.303968
SPLIT TN1 SUPPLY FAN 0.240860
SPLIT TN2 SUPPLY FAN 0.240853
SPLIT TS1 SUPPLY FAN 0.259418
SPLIT TS2 SUPPLY FAN 0.259795


Coil:Heating:Gas

Nominal Capacity [W]
SPLIT GSW HEATING COIL 1946.11
SPLIT GNW HEATING COIL 1928.35
SPLIT OFFICE HEATING COIL 3616.86
SPLIT GNE HEATING COIL 1933.09
SPLIT GN1 HEATING COIL 1503.38
SPLIT GN2 HEATING COIL 1503.38
SPLIT GS1 HEATING COIL 1503.38
SPLIT GS2 HEATING COIL 1504.62
SPLIT MSW HEATING COIL 3739.52
SPLIT MNW HEATING COIL 3761.73
SPLIT MSE HEATING COIL 3752.38
SPLIT MNE HEATING COIL 3774.58
SPLIT MN1 HEATING COIL 3006.76
SPLIT MN2 HEATING COIL 3006.76
SPLIT MS1 HEATING COIL 3006.76
SPLIT MS2 HEATING COIL 3006.76
SPLIT TSW HEATING COIL 2971.95
SPLIT TNW HEATING COIL 2985.12
SPLIT TSE HEATING COIL 2978.70
SPLIT TNE HEATING COIL 2991.88
SPLIT TN1 HEATING COIL 2320.77
SPLIT TN2 HEATING COIL 2320.96
SPLIT TS1 HEATING COIL 2305.62
SPLIT TS2 HEATING COIL 2305.82



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:31

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW1 S SWA |
G WWALL SWA GWINDOW1 W SWA |
G NWALL NWA GWINDOW1 N NWA |
G WWALL NWA GWINDOW1 W NWA |
G SWALL SEA GWINDOW1 S SEA |
G EWALL SEA GWINDOW1 E SEA |
G NWALL NEA GWINDOW1 N NEA |
G EWALL NEA GWINDOW1 E NEA |
G NWALL N1A GWINDOW1 N N1A |
G NWALL N2A GWINDOW1 N N2A |
G SWALL S1A GWINDOW1 S S1A |
G SWALL S2A GWINDOW1 S S2A |
M WWALL SWA MWINDOW1 W SWA |
M SWALL SWA MWINDOW1 S SWA |
M NWALL NWA MWINDOW1 N NWA |
M WWALL NWA MWINDOW1 W NWA |
M EWALL SEA MWINDOW1 E SEA |
M SWALL SEA MWINDOW1 S SEA |
M NWALL NEA MWINDOW1 N NEA |
M EWALL NEA MWINDOW1 E NEA |
M NWALL N1A MWINDOW1 N N1A |
M NWALL N2A MWINDOW1 N N2A |
M SWALL S1A MWINDOW1 S S1A |
M SWALL S2A MWINDOW1 S S2A |
T WWALL SWA TWINDOW1 W SWA |
T SWALL SWA TWINDOW1 S SWA |
T NWALL NWA TWINDOW1 N NWA |
T WWALL NWA TWINDOW1 W NWA |
T EWALL SEA TWINDOW1 E SEA |
T SWALL SEA TWINDOW1 S SEA |
T NWALL NEA TWINDOW1 N NEA |
T EWALL NEA TWINDOW1 E NEA |
T NWALL N1A TWINDOW1 N N1A |
T NWALL N2A TWINDOW1 N N2A |
T SWALL S1A TWINDOW1 S S1A |
T SWALL S2A TWINDOW1 S S2A |
T EWALL C TWINDOW14 |
G EWALL C ENTRANCE DOOR |
M EWALL C MWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:31

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.39 8.14
February 22.60 10.27
March 22.83 12.55
April 23.74 19.23
May 24.23 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.39 23.38
October 23.98 18.30
November 22.96 11.18
December 22.37 6.79
     
Annual Sum or Average 23.56 17.98
Minimum of Months 22.37 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.83 8.14
February 22.07 10.27
March 22.43 12.55
April 23.62 19.23
May 24.23 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.39 23.38
October 23.74 18.30
November 22.29 11.18
December 21.81 6.79
     
Annual Sum or Average 23.31 17.98
Minimum of Months 21.81 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.92 8.14
February 23.34 10.27
March 23.74 12.55
April 25.16 19.23
May 25.96 23.84
June 27.14 27.86
July 27.31 27.54
August 27.01 26.28
September 27.02 23.38
October 25.29 18.30
November 23.90 11.18
December 22.86 6.79
     
Annual Sum or Average 25.14 17.98
Minimum of Months 22.86 6.79
Maximum of Months 27.31 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.75 8.14
February 22.01 10.27
March 22.37 12.55
April 23.62 19.23
May 24.23 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.39 23.38
October 23.67 18.30
November 22.18 11.18
December 21.75 6.79
     
Annual Sum or Average 23.27 17.98
Minimum of Months 21.75 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.76 8.14
February 21.95 10.27
March 22.23 12.55
April 23.47 19.23
May 24.17 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.39 23.38
October 23.64 18.30
November 22.15 11.18
December 21.76 6.79
     
Annual Sum or Average 23.23 17.98
Minimum of Months 21.76 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.75 8.14
February 21.95 10.27
March 22.23 12.55
April 23.47 19.23
May 24.17 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.39 23.38
October 23.63 18.30
November 22.14 11.18
December 21.75 6.79
     
Annual Sum or Average 23.23 17.98
Minimum of Months 21.75 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.39 8.14
February 22.61 10.27
March 22.76 12.55
April 23.66 19.23
May 24.18 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.40 23.38
October 23.97 18.30
November 23.00 11.18
December 22.39 6.79
     
Annual Sum or Average 23.55 17.98
Minimum of Months 22.39 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.41 8.14
February 22.63 10.27
March 22.79 12.55
April 23.70 19.23
May 24.21 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.40 23.38
October 24.00 18.30
November 23.03 11.18
December 22.40 6.79
     
Annual Sum or Average 23.57 17.98
Minimum of Months 22.40 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.64 8.14
February 23.89 10.27
March 24.10 12.55
April 24.34 19.23
May 24.40 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.40 23.38
October 24.40 18.30
November 24.05 11.18
December 23.52 6.79
     
Annual Sum or Average 24.16 17.98
Minimum of Months 23.52 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.55 8.14
February 23.16 10.27
March 23.81 12.55
April 24.31 19.23
May 24.40 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.40 23.38
October 24.38 18.30
November 23.62 11.18
December 22.35 6.79
     
Annual Sum or Average 23.85 17.98
Minimum of Months 22.35 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.58 8.14
February 23.88 10.27
March 24.09 12.55
April 24.34 19.23
May 24.40 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.40 23.38
October 24.39 18.30
November 24.00 11.18
December 23.47 6.79
     
Annual Sum or Average 24.15 17.98
Minimum of Months 23.47 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.35 8.14
February 23.10 10.27
March 23.77 12.55
April 24.31 19.23
May 24.40 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.40 23.38
October 24.37 18.30
November 23.54 11.18
December 22.23 6.79
     
Annual Sum or Average 23.81 17.98
Minimum of Months 22.23 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.74 8.14
February 23.34 10.27
March 23.94 12.55
April 24.34 19.23
May 24.40 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.40 23.38
October 24.39 18.30
November 23.81 11.18
December 22.49 6.79
     
Annual Sum or Average 23.92 17.98
Minimum of Months 22.49 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.72 8.14
February 23.34 10.27
March 23.94 12.55
April 24.34 19.23
May 24.40 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.40 23.38
October 24.39 18.30
November 23.80 11.18
December 22.48 6.79
     
Annual Sum or Average 23.92 17.98
Minimum of Months 22.48 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.96 8.14
February 24.12 10.27
March 24.24 12.55
April 24.37 19.23
May 24.40 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.40 23.38
October 24.40 18.30
November 24.20 11.18
December 23.86 6.79
     
Annual Sum or Average 24.26 17.98
Minimum of Months 23.86 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.96 8.14
February 24.12 10.27
March 24.24 12.55
April 24.37 19.23
May 24.40 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.40 23.38
October 24.40 18.30
November 24.20 11.18
December 23.85 6.79
     
Annual Sum or Average 24.26 17.98
Minimum of Months 23.85 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.85 8.14
February 23.15 10.27
March 23.43 12.55
April 24.13 19.23
May 24.37 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.39 23.38
October 24.23 18.30
November 23.33 11.18
December 22.83 6.79
     
Annual Sum or Average 23.83 17.98
Minimum of Months 22.83 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.27 8.14
February 22.69 10.27
March 23.18 12.55
April 24.08 19.23
May 24.37 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.39 23.38
October 24.14 18.30
November 22.91 11.18
December 22.17 6.79
     
Annual Sum or Average 23.62 17.98
Minimum of Months 22.17 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.85 8.14
February 23.16 10.27
March 23.46 12.55
April 24.14 19.23
May 24.37 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.39 23.38
October 24.21 18.30
November 23.31 11.18
December 22.83 6.79
     
Annual Sum or Average 23.83 17.98
Minimum of Months 22.83 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.15 8.14
February 22.67 10.27
March 23.19 12.55
April 24.09 19.23
May 24.37 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.38 23.38
October 24.11 18.30
November 22.87 11.18
December 22.07 6.79
     
Annual Sum or Average 23.59 17.98
Minimum of Months 22.07 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.20 8.14
February 22.70 10.27
March 23.22 12.55
April 24.12 19.23
May 24.38 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.39 23.38
October 24.19 18.30
November 22.94 11.18
December 22.08 6.79
     
Annual Sum or Average 23.62 17.98
Minimum of Months 22.08 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.19 8.14
February 22.70 10.27
March 23.23 12.55
April 24.12 19.23
May 24.38 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.39 23.38
October 24.19 18.30
November 22.93 11.18
December 22.08 6.79
     
Annual Sum or Average 23.62 17.98
Minimum of Months 22.08 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.99 8.14
February 23.31 10.27
March 23.57 12.55
April 24.19 19.23
May 24.38 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.39 23.38
October 24.29 18.30
November 23.47 11.18
December 22.95 6.79
     
Annual Sum or Average 23.90 17.98
Minimum of Months 22.95 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.99 8.14
February 23.31 10.27
March 23.57 12.55
April 24.19 19.23
May 24.38 23.84
June 24.40 27.86
July 24.40 27.54
August 24.40 26.28
September 24.39 23.38
October 24.29 18.30
November 23.46 11.18
December 22.95 6.79
     
Annual Sum or Average 23.90 17.98
Minimum of Months 22.95 6.79
Maximum of Months 24.40 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.93 8.14
February 23.55 10.27
March 24.26 12.55
April 25.78 19.23
May 26.56 23.84
June 27.12 27.86
July 27.16 27.54
August 26.98 26.28
September 26.64 23.38
October 25.80 18.30
November 23.89 11.18
December 22.66 6.79
     
Annual Sum or Average 25.28 17.98
Minimum of Months 22.66 6.79
Maximum of Months 27.16 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.87 8.14
February 21.48 10.27
March 22.15 12.55
April 23.95 19.23
May 25.24 23.84
June 26.98 27.86
July 27.08 27.54
August 26.84 26.28
September 26.37 23.38
October 24.17 18.30
November 21.97 11.18
December 20.69 6.79
     
Annual Sum or Average 23.99 17.98
Minimum of Months 20.69 6.79
Maximum of Months 27.08 27.86



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2015-09-09 18:47:31

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.81 8.14
February 25.30 10.27
March 25.81 12.55
April 26.46 19.23
May 26.75 23.84
June 26.97 27.86
July 26.94 27.54
August 26.88 26.28
September 26.80 23.38
October 26.52 18.30
November 25.72 11.18
December 24.62 6.79
     
Annual Sum or Average 26.14 17.98
Minimum of Months 24.62 6.79
Maximum of Months 26.97 27.86



Table of Contents

Report: PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2015-09-09 18:47:31

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY [Invalid/Undefined] HEATREJECTION:ELECTRICITY [Invalid/Undefined] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined]
January 0.115269E+12 70245.240 13-JAN-18:30 4979.953 26630.920 8103.106 0.000 1723.749 2553.000 0.000 0.000 0.000 0.000 0.000 26254.512 0.000 0.000 0.000
February 0.104987E+12 71409.749 19-FEB-18:15 4979.953 26630.920 8103.106 0.000 4891.179 2553.000 0.000 0.000 0.000 0.000 0.000 24251.591 0.000 0.000 0.000
March 0.116295E+12 71853.771 21-MAR-17:30 4979.953 26630.920 8103.106 0.000 8272.898 0.000 0.000 0.000 0.000 0.000 0.000 23866.894 0.000 0.000 0.000
April 0.119643E+12 75686.510 30-APR-17:30 4979.953 26630.920 8103.106 0.000 14853.274 0.000 0.000 0.000 0.000 0.000 0.000 21119.257 0.000 0.000 0.000
May 0.129929E+12 76096.268 19-MAY-17:15 4979.953 26630.920 8103.106 0.000 19871.962 0.000 0.000 0.000 0.000 0.000 0.000 16510.327 0.000 0.000 0.000
June 0.134238E+12 81748.525 15-JUN-16:00 4276.255 26730.986 8103.106 0.000 24571.469 0.000 0.000 0.000 0.000 0.000 0.000 18066.708 0.000 0.000 0.000
July 0.140488E+12 83900.917 26-JUL-17:45 4979.953 26630.920 8103.106 0.000 22630.760 0.000 0.000 0.000 0.000 0.000 0.000 21556.178 0.000 0.000 0.000
August 0.136185E+12 82861.937 07-AUG-17:30 4979.953 26630.920 8103.106 0.000 21021.139 0.000 0.000 0.000 0.000 0.000 0.000 22126.818 0.000 0.000 0.000
September 0.128055E+12 76950.937 20-SEP-16:15 4276.255 26730.986 8103.106 0.000 18773.099 0.000 0.000 0.000 0.000 0.000 0.000 19067.490 0.000 0.000 0.000
October 0.122119E+12 75558.365 05-OCT-17:45 4979.953 26630.920 8103.106 0.000 14057.457 2553.000 0.000 0.000 0.000 0.000 0.000 19233.928 0.000 0.000 0.000
November 0.111198E+12 69095.113 11-NOV-18:15 4979.953 26630.920 8103.106 0.000 3963.011 2553.000 0.000 0.000 0.000 0.000 0.000 22865.122 0.000 0.000 0.000
December 0.113931E+12 69262.187 31-DEC-18:45 4979.953 26630.920 8103.106 0.000 241.812 2553.000 0.000 0.000 0.000 0.000 0.000 26753.396 0.000 0.000 0.000
                                     
Annual Sum or Average 0.147234E+13                 0.000 0.000 0.000 0.000 0.000   0.000 0.000 0.000
Minimum of Months 0.104987E+12 69095.113   4276.255 26630.920 8103.106 0.000 241.812 0.000 0.000 0.000 0.000 0.000 0.000 16510.327 0.000 0.000 0.000
Maximum of Months 0.140488E+12 83900.917   4979.953 26730.986 8103.106 0.000 24571.469 2553.000 0.000 0.000 0.000 0.000 0.000 26753.396 0.000 0.000 0.000



Table of Contents

Report: PEAK GAS DEMAND

For: Meter

Timestamp: 2015-09-09 18:47:31

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC {AT MAX/MIN} [W] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT [Invalid/Undefined] WATERSYSTEMS:GAS [Invalid/Undefined] WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] HEATING:GAS {AT MAX/MIN} [W]
January 0.135777E+11 38020.190 28-JAN-05:00 38020.190 0.000 0.000 0.000 0.000 0.000 38020.190
February 0.859951E+10 33059.710 09-FEB-01:15 33059.710 0.000 0.000 0.000 0.000 0.000 33059.710
March 0.403183E+10 26569.010 02-MAR-05:00 26569.010 0.000 0.000 0.000 0.000 0.000 26569.010
April 0.404539E+09 13896.510 11-APR-01:00 13896.510 0.000 0.000 0.000 0.000 0.000 13896.510
May 0.000 0.000 01-MAY-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
June 0.000 0.000 01-JUN-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
July 0.000 0.000 01-JUL-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 0.000 0.000 01-AUG-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
September 0.000 0.000 01-SEP-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
October 5255214.127 1040.382 25-OCT-05:00 1040.382 0.000 0.000 0.000 0.000 0.000 1040.382
November 0.523019E+10 33316.154 28-NOV-04:00 33316.154 0.000 0.000 0.000 0.000 0.000 33316.154
December 0.173720E+11 37891.297 27-DEC-07:30 37891.297 0.000 0.000 0.000 0.000 0.000 37891.297
                     
Annual Sum or Average 0.492210E+11       0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.000 0.000   0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.173720E+11 38020.190   38020.190 0.000 0.000 0.000 0.000 0.000 38020.190