Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:47
Tabular Output Report in Format: HTML
Building: Mid-Rise Apartment
Environment: Duluth International Arpt MN USA TMY3 WMO#=727450
Simulation Timestamp: 2015-09-09 18:47:40
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:40
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 2320.61 | 740.32 | 821.75 |
Net Site Energy | 2320.61 | 740.32 | 821.75 |
Total Source Energy | 5430.22 | 1732.34 | 1922.90 |
Net Source Energy | 5430.22 | 1732.34 | 1922.90 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 3134.61 |
Net Conditioned Building Area | 2823.98 |
Unconditioned Building Area | 310.64 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 921.33 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 51.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 118.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 40.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 517.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 208.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 463.66 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1399.27 | 921.33 | 0.00 | 0.00 | 0.00 | 1874.72 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 921.33 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 51.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 96.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 22.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 40.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 517.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 208.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 463.66 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 56.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 256.06 | 326.25 | 0.00 | 0.00 | 0.00 | 0.66 |
Other | 183.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 495.50 | 326.25 | 0.00 | 0.00 | 0.00 | 0.66 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 50.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 230.69 | 293.92 | 0.00 | 0.00 | 0.00 | 0.60 |
Other | 165.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 446.39 | 293.92 | 0.00 | 0.00 | 0.00 | 0.60 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 1399.27 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 1399.27 | 100.00 |
Total On-Site and Utility Electric Sources | 1399.27 | 100.00 |
Total Electricity End Uses | 1399.27 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 1874.72 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 1874.72 | 100.00 |
Total Water End Uses | 1874.72 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 38.00 |
Time Setpoint Not Met During Occupied Cooling | 1.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 3971.25 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PEAK ELECTRICAL DEMAND
| Meter |PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:40
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:47 |
RunPeriod | Duluth International Arpt MN USA TMY3 WMO#=727450 |
Weather File | Duluth International Arpt MN USA TMY3 WMO#=727450 |
Latitude [deg] | 46.83 |
Longitude [deg] | -92.2 |
Elevation [m] | 433.00 |
Time Zone | -6.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
Window Opening Area [m2] | 306.92 | 112.97 | 37.16 | 112.97 | 43.82 |
Window-Wall Ratio [%] | 19.90 | 20.00 | 18.02 | 20.00 | 21.25 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 26.1977 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 1.11 | 5.9540 | 0.0000 | |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 3.32 | 5.9540 | 208.8202 | |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 1.11 | 5.9540 | 0.0000 | |
Total | 3134.61 | 9553.84 | 1542.04 | 306.92 | 4.5346 | 39.93 | 11.1825 | |||
Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 300.26 | 4.3785 | 35.97 | 6.6700 | |||
Unconditioned Total | 310.64 | 946.78 | 40.87 | 6.66 | 5.9540 | 52.2051 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:40
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 28-JUN-17:00 | 19-DEC-02:00 | - | - | - | 01-JAN-07:15 |
Heating | 0.00 | 177327.73 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 17033.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 4979.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 26630.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 6602.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 30600.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 85847.16 | 177327.73 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 177327.73 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 17033.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 4056.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 923.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 26630.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 6602.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 30600.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:40
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 998.73 | 0.00 | 0.00 | 0.00 |
Cooling | 162.26 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 375.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 126.83 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1639.40 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 659.40 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 1468.42 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 4431.50 | 998.73 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 353.66 | 0.00 | 0.00 | 0.00 |
Cooling | 57.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 132.85 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.91 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 580.53 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 233.50 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 519.98 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1569.24 | 353.66 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 353.66 | 0.00 | 0.00 | 0.00 |
Cooling | 57.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 132.85 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.91 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 580.53 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 233.50 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 519.98 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1569.24 | 353.66 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:40
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | -28.60 | 0.00 | -28.60 | Wetbulb [C] | 4.60 | 310.00 |
DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 29.20 | 10.90 | 21.00 | Wetbulb [C] | 5.20 | 220.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:40
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 46.45 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 70.60 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 70.60 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 46.45 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 46.45 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 70.60 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 70.60 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 46.45 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 70.60 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 70.60 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 70.60 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 70.60 | 180.00 | 90.00 | S |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.30 | 0.219 | 0.228 | 88.25 | 180.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.30 | 0.219 | 0.228 | 88.25 | 180.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.30 | 0.219 | 0.228 | 88.25 | 180.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.30 | 0.219 | 0.228 | 88.25 | 180.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.30 | 0.219 | 0.228 | 88.25 | 180.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.30 | 0.219 | 0.228 | 88.25 | 180.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.30 | 0.219 | 0.228 | 88.25 | 180.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.30 | 0.219 | 0.228 | 88.25 | 180.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.30 | 0.219 | 0.228 | 77.66 | 180.00 | 0.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 90.00 | 180.00 | |
M WWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 10.22 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.295 | 0.309 | 10.22 | 90.00 | 90.00 | E |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW1 S SWA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW1 W SWA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW1 N NWA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW1 W NWA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 S SEA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW1 E SEA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW1 N NEA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW1 E NEA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW1 N N1A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW1 N N2A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW1 S S1A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW1 S S2A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW1 W SWA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.493 | 0.426 | 0.308 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW1 S SWA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW1 N NWA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW1 W NWA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.493 | 0.426 | 0.308 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW1 E SEA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.493 | 0.426 | 0.308 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 S SEA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW1 N NEA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW1 E NEA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.493 | 0.426 | 0.308 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW1 N N1A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW1 N N2A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW1 S S1A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW1 S S2A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.493 | 0.426 | 0.308 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW1 W SWA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW1 S SWA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW1 N NWA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW1 W NWA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW1 E SEA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 S SEA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW1 N NEA | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW1 E NEA | WINDOW_U_0.42_SHGC_0.45 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.493 | 0.426 | 0.308 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW1 N N1A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW1 N N2A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW1 S S1A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW1 S S2A | WINDOW_U_0.42_SHGC_0.45 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.493 | 0.426 | 0.308 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.493 | 0.426 | 0.308 | No | T EWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_0.42_SHGC_0.45 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 2.493 | 0.426 | 0.308 | No | G EWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_0.42_SHGC_0.45 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 2.493 | 0.426 | 0.308 | No | M EWALL C | 270.00 | 90.00 | W | ||
Total or Average | 306.92 | 2.493 | 0.426 | 0.308 | ||||||||||||
North Total or Average | 112.97 | 2.493 | 0.426 | 0.308 | ||||||||||||
Non-North Total or Average | 193.95 | 2.493 | 0.426 | 0.308 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:40
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:40
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
LIGHTING_HARDWIRED_GSW | G SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GNW | G NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_OFFICE | OFFICE | 13.0989 | 88.25 | 1155.96 | GeneralLights | LTG_OFF_SCH | 62.17 | 168.00 | 60.95 | 0.0000 | Y | 13.23 |
LIGHTING_HARDWIRED_GNE | G NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MSW | M SW APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MNW | M NW APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MSE | M SE APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MNE | M NE APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TSW | T SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TNW | T NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TSE | T SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TNE | T NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GC | G CORRIDOR | 5.9540 | 77.66 | 462.39 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 14.58 |
LIGHTING_HARDWIRED_MC | M CORRIDOR | 5.9540 | 155.32 | 924.77 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 14.58 |
LIGHTING_HARDWIRED_TC | T CORRIDOR | 5.9540 | 77.66 | 462.39 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 14.58 |
LIGHTING_PLUGIN_GSW | G SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_GNW | G NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_OFFICE | OFFICE | 13.0989 | 88.25 | 1155.96 | GeneralLights-plugin | LTG_OFF_SCH | 62.17 | 168.00 | 60.95 | 0.0000 | Y | 13.23 |
LIGHTING_PLUGIN_GNE | G NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MSW | M SW APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MNW | M NW APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MSE | M SE APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MNE | M NE APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TSW | T SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TNW | T NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TSE | T SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TNE | T NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
Interior Lighting Total | 2.3855 | 5958.59 | 14214.30 | 95.19 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 2553.00 | AstronomicalClock | - | 83.57 | 83.57 | 40.05 | |
Exterior Lighting Total | 2553.00 | 40.05 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:40
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2836.41 | 2147.06 | 689.35 | 0.76 | 3.91 | |||
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2623.54 | 1980.36 | 643.18 | 0.75 | 3.91 | |||
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7699.75 | 6149.45 | 1550.30 | 0.80 | 3.91 | |||
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2057.81 | 1509.15 | 548.66 | 0.73 | 3.91 | |||
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1556.86 | 1131.32 | 425.54 | 0.73 | 3.91 | |||
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1538.85 | 1116.71 | 422.14 | 0.73 | 3.91 | |||
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2050.66 | 1492.52 | 558.14 | 0.73 | 3.91 | |||
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2099.60 | 1534.63 | 564.97 | 0.73 | 3.91 | |||
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7946.89 | 6144.41 | 1802.48 | 0.77 | 3.91 | |||
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7324.81 | 5638.56 | 1686.25 | 0.77 | 3.91 | |||
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7560.72 | 5752.86 | 1807.86 | 0.76 | 3.91 | |||
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5870.72 | 4447.39 | 1423.33 | 0.76 | 3.91 | |||
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4591.43 | 3458.10 | 1133.33 | 0.75 | 3.91 | |||
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4561.02 | 3432.96 | 1128.06 | 0.75 | 3.91 | |||
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5898.60 | 4442.33 | 1456.27 | 0.75 | 3.91 | |||
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5919.29 | 4459.61 | 1459.68 | 0.75 | 3.91 | |||
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5169.68 | 4005.51 | 1164.17 | 0.77 | 3.91 | |||
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4588.20 | 3554.17 | 1034.04 | 0.77 | 3.91 | |||
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4894.68 | 3768.22 | 1126.46 | 0.77 | 3.91 | |||
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3819.29 | 2874.83 | 944.46 | 0.75 | 3.91 | |||
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2993.03 | 2240.81 | 752.22 | 0.75 | 3.91 | |||
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3000.58 | 2244.17 | 756.41 | 0.75 | 3.91 | |||
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4024.69 | 3094.15 | 930.54 | 0.77 | 3.91 | |||
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4038.78 | 3105.96 | 932.82 | 0.77 | 3.91 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2717.2 | 3.20 | 10.92 | 11.36 | 10.74 |
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2513.9 | 3.20 | 10.93 | 11.37 | 10.76 |
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7335.2 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1977.5 | 3.24 | 11.07 | 11.52 | 10.95 |
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1497.4 | 3.26 | 11.11 | 11.56 | 11.02 |
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1480.3 | 3.26 | 11.11 | 11.57 | 11.03 |
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1972.0 | 3.25 | 11.10 | 11.55 | 11.01 |
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2018.3 | 3.25 | 11.08 | 11.53 | 10.98 |
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7596.4 | 3.17 | 10.82 | 11.25 | 10.60 |
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7004.9 | 3.18 | 10.84 | 11.27 | 10.63 |
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7239.1 | 3.19 | 10.90 | 11.33 | 10.70 |
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5623.4 | 3.20 | 10.92 | 11.36 | 10.73 |
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4400.6 | 3.21 | 10.94 | 11.38 | 10.77 |
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4371.7 | 3.21 | 10.95 | 11.39 | 10.78 |
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5653.5 | 3.21 | 10.94 | 11.38 | 10.77 |
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5673.1 | 3.21 | 10.94 | 11.38 | 10.77 |
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4940.6 | 3.17 | 10.81 | 11.24 | 10.58 |
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4385.0 | 3.17 | 10.81 | 11.24 | 10.58 |
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4680.9 | 3.18 | 10.84 | 11.27 | 10.62 |
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3660.8 | 3.21 | 10.95 | 11.39 | 10.78 |
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2870.3 | 3.22 | 10.97 | 11.41 | 10.81 |
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2877.9 | 3.22 | 10.98 | 11.42 | 10.82 |
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3849.4 | 3.18 | 10.85 | 11.28 | 10.63 |
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3862.8 | 3.18 | 10.85 | 11.28 | 10.63 |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
SPLIT GSW HEATING COIL | Coil:Heating:Gas | 4869.23 | 0.80 | |
SPLIT GNW HEATING COIL | Coil:Heating:Gas | 4839.39 | 0.80 | |
SPLIT OFFICE HEATING COIL | Coil:Heating:Gas | 7734.25 | 0.80 | |
SPLIT GNE HEATING COIL | Coil:Heating:Gas | 4825.90 | 0.80 | |
SPLIT GN1 HEATING COIL | Coil:Heating:Gas | 3678.62 | 0.80 | |
SPLIT GN2 HEATING COIL | Coil:Heating:Gas | 3678.32 | 0.80 | |
SPLIT GS1 HEATING COIL | Coil:Heating:Gas | 3657.29 | 0.80 | |
SPLIT GS2 HEATING COIL | Coil:Heating:Gas | 3794.38 | 0.80 | |
SPLIT MSW HEATING COIL | Coil:Heating:Gas | 9724.61 | 0.80 | |
SPLIT MNW HEATING COIL | Coil:Heating:Gas | 9781.53 | 0.80 | |
SPLIT MSE HEATING COIL | Coil:Heating:Gas | 9689.57 | 0.80 | |
SPLIT MNE HEATING COIL | Coil:Heating:Gas | 9746.46 | 0.80 | |
SPLIT MN1 HEATING COIL | Coil:Heating:Gas | 6801.41 | 0.80 | |
SPLIT MN2 HEATING COIL | Coil:Heating:Gas | 6800.57 | 0.80 | |
SPLIT MS1 HEATING COIL | Coil:Heating:Gas | 6747.17 | 0.80 | |
SPLIT MS2 HEATING COIL | Coil:Heating:Gas | 6746.34 | 0.80 | |
SPLIT TSW HEATING COIL | Coil:Heating:Gas | 6783.04 | 0.80 | |
SPLIT TNW HEATING COIL | Coil:Heating:Gas | 6814.92 | 0.80 | |
SPLIT TSE HEATING COIL | Coil:Heating:Gas | 6764.56 | 0.80 | |
SPLIT TNE HEATING COIL | Coil:Heating:Gas | 6796.43 | 0.80 | |
SPLIT TN1 HEATING COIL | Coil:Heating:Gas | 5121.17 | 0.80 | |
SPLIT TN2 HEATING COIL | Coil:Heating:Gas | 5120.70 | 0.80 | |
SPLIT TS1 HEATING COIL | Coil:Heating:Gas | 5087.63 | 0.80 | |
SPLIT TS2 HEATING COIL | Coil:Heating:Gas | 5087.16 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.15 | 176.35 | 1160.84 | 1.00 | General |
SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.14 | 162.05 | 1160.84 | 1.00 | General |
SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.47 | 539.95 | 1160.84 | 1.00 | General |
SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.10 | 118.68 | 1160.84 | 1.00 | General |
SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.08 | 87.80 | 1160.84 | 1.00 | General |
SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.07 | 86.49 | 1160.84 | 1.00 | General |
SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.10 | 116.10 | 1160.84 | 1.00 | General |
SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.10 | 120.11 | 1160.84 | 1.00 | General |
SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.45 | 518.68 | 1160.84 | 1.00 | General |
SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.41 | 473.33 | 1160.84 | 1.00 | General |
SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.41 | 475.74 | 1160.84 | 1.00 | General |
SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 365.67 | 1160.84 | 1.00 | General |
SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 282.14 | 1160.84 | 1.00 | General |
SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.24 | 279.85 | 1160.84 | 1.00 | General |
SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 362.41 | 1160.84 | 1.00 | General |
SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.31 | 364.01 | 1160.84 | 1.00 | General |
SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.29 | 339.02 | 1160.84 | 1.00 | General |
SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.26 | 300.73 | 1160.84 | 1.00 | General |
SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 316.36 | 1160.84 | 1.00 | General |
SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.20 | 234.36 | 1160.84 | 1.00 | General |
SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 181.36 | 1160.84 | 1.00 | General |
SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 181.38 | 1160.84 | 1.00 | General |
SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 259.31 | 1160.84 | 1.00 | General |
SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.22 | 260.41 | 1160.84 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
G SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:40
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 1535.44 | 1842.53 | 0.127 | 0.152 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 26.86 | 0.01308 |
G NW APARTMENT | 1410.95 | 1693.15 | 0.116 | 0.140 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 26.18 | 0.01308 |
OFFICE | 4602.66 | 5523.20 | 0.388 | 0.465 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 | 23.20 | 0.01308 |
G NE APARTMENT | 979.77 | 1175.72 | 0.081 | 0.097 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 25.47 | 0.01308 |
G N1 APARTMENT | 764.46 | 917.36 | 0.063 | 0.076 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
G N2 APARTMENT | 753.10 | 903.71 | 0.062 | 0.075 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
G S1 APARTMENT | 1010.82 | 1212.99 | 0.083 | 0.100 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
G S2 APARTMENT | 1045.73 | 1254.87 | 0.086 | 0.103 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 28.93 | 0.01308 |
M SW APARTMENT | 4515.89 | 5419.07 | 0.372 | 0.447 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 26.86 | 0.01308 |
M NW APARTMENT | 4121.06 | 4945.27 | 0.340 | 0.408 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 26.18 | 0.01308 |
M SE APARTMENT | 4141.78 | 4970.14 | 0.342 | 0.410 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 28.93 | 0.01308 |
M NE APARTMENT | 3183.46 | 3820.15 | 0.263 | 0.315 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 25.88 | 0.01308 |
M N1 APARTMENT | 2456.55 | 2947.86 | 0.203 | 0.243 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
M N2 APARTMENT | 2436.56 | 2923.87 | 0.201 | 0.241 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 24.95 | 0.01308 |
M S1 APARTMENT | 3155.30 | 3786.36 | 0.260 | 0.312 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
M S2 APARTMENT | 3169.18 | 3803.02 | 0.261 | 0.314 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
T SW APARTMENT | 2951.29 | 3541.54 | 0.243 | 0.292 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:45:00 | 28.71 | 0.01308 |
T NW APARTMENT | 2618.22 | 3141.87 | 0.216 | 0.259 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 26.86 | 0.01308 |
T SE APARTMENT | 2754.08 | 3304.90 | 0.227 | 0.273 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 29.06 | 0.01308 |
T NE APARTMENT | 2040.25 | 2448.30 | 0.168 | 0.202 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 29.20 | 0.01308 |
T N1 APARTMENT | 1578.92 | 1894.70 | 0.130 | 0.156 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:15:00 | 29.04 | 0.01308 |
T N2 APARTMENT | 1579.10 | 1894.91 | 0.130 | 0.156 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 29.20 | 0.01308 |
T S1 APARTMENT | 2257.59 | 2709.11 | 0.186 | 0.223 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 29.20 | 0.01308 |
T S2 APARTMENT | 2267.12 | 2720.54 | 0.187 | 0.224 | DULUTH INTERNATIONAL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 29.20 | 0.01308 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 2802.71 | 3363.25 | 0.085 | 0.102 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -28.60 | 0.00028 |
G NW APARTMENT | 2823.70 | 3388.44 | 0.086 | 0.103 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -28.60 | 0.00028 |
OFFICE | 4728.61 | 5674.34 | 0.139 | 0.167 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -28.60 | 0.00028 |
G NE APARTMENT | 2812.30 | 3374.75 | 0.085 | 0.102 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -28.60 | 0.00028 |
G N1 APARTMENT | 1842.08 | 2210.49 | 0.056 | 0.067 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -28.60 | 0.00028 |
G N2 APARTMENT | 1841.82 | 2210.19 | 0.056 | 0.067 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -28.60 | 0.00028 |
G S1 APARTMENT | 1824.04 | 2188.85 | 0.055 | 0.066 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -28.60 | 0.00028 |
G S2 APARTMENT | 1939.97 | 2327.96 | 0.059 | 0.071 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -28.60 | 0.00028 |
M SW APARTMENT | 5686.40 | 6823.68 | 0.172 | 0.207 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -28.60 | 0.00028 |
M NW APARTMENT | 5734.53 | 6881.43 | 0.174 | 0.208 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -28.60 | 0.00028 |
M SE APARTMENT | 5656.77 | 6788.12 | 0.171 | 0.206 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -28.60 | 0.00028 |
M NE APARTMENT | 5704.88 | 6845.85 | 0.173 | 0.207 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -28.60 | 0.00028 |
M N1 APARTMENT | 3214.26 | 3857.12 | 0.097 | 0.117 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -28.60 | 0.00028 |
M N2 APARTMENT | 3213.56 | 3856.27 | 0.097 | 0.117 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -28.60 | 0.00028 |
M S1 APARTMENT | 3168.40 | 3802.07 | 0.096 | 0.115 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -28.60 | 0.00028 |
M S2 APARTMENT | 3167.70 | 3801.23 | 0.096 | 0.115 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -28.60 | 0.00028 |
T SW APARTMENT | 4467.53 | 5361.04 | 0.135 | 0.162 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -28.60 | 0.00028 |
T NW APARTMENT | 4494.49 | 5393.39 | 0.136 | 0.163 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -28.60 | 0.00028 |
T SE APARTMENT | 4451.90 | 5342.28 | 0.135 | 0.162 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -28.60 | 0.00028 |
T NE APARTMENT | 4478.85 | 5374.62 | 0.136 | 0.163 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -28.60 | 0.00028 |
T N1 APARTMENT | 3062.08 | 3674.50 | 0.093 | 0.111 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -28.60 | 0.00028 |
T N2 APARTMENT | 3061.69 | 3674.02 | 0.093 | 0.111 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -28.60 | 0.00028 |
T S1 APARTMENT | 3033.72 | 3640.46 | 0.092 | 0.110 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -28.60 | 0.00028 |
T S2 APARTMENT | 3033.32 | 3639.99 | 0.092 | 0.110 | DULUTH INTERNATIONAL ARPT ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -28.60 | 0.00028 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
SPLIT GSW | 0.15 | 0.15 | 0.10 | 0.10 |
SPLIT GNW | 0.14 | 0.14 | 0.10 | 0.10 |
SPLIT OFFICE | 0.47 | 0.47 | 0.17 | 0.17 |
SPLIT GNE | 0.10 | 0.10 | 0.10 | 0.10 |
SPLIT GN1 | 0.08 | 0.08 | 0.07 | 0.07 |
SPLIT GN2 | 0.07 | 0.07 | 0.07 | 0.07 |
SPLIT GS1 | 0.10 | 0.10 | 0.07 | 0.07 |
SPLIT GS2 | 0.10 | 0.10 | 0.07 | 0.07 |
SPLIT MSW | 0.45 | 0.45 | 0.21 | 0.21 |
SPLIT MNW | 0.41 | 0.41 | 0.21 | 0.21 |
SPLIT MSE | 0.41 | 0.41 | 0.21 | 0.21 |
SPLIT MNE | 0.32 | 0.32 | 0.21 | 0.21 |
SPLIT MN1 | 0.24 | 0.24 | 0.12 | 0.12 |
SPLIT MN2 | 0.24 | 0.24 | 0.12 | 0.12 |
SPLIT MS1 | 0.31 | 0.31 | 0.12 | 0.12 |
SPLIT MS2 | 0.31 | 0.31 | 0.12 | 0.12 |
SPLIT TSW | 0.29 | 0.29 | 0.16 | 0.16 |
SPLIT TNW | 0.26 | 0.26 | 0.16 | 0.16 |
SPLIT TSE | 0.27 | 0.27 | 0.16 | 0.16 |
SPLIT TNE | 0.20 | 0.20 | 0.16 | 0.16 |
SPLIT TN1 | 0.16 | 0.16 | 0.11 | 0.11 |
SPLIT TN2 | 0.16 | 0.16 | 0.11 | 0.11 |
SPLIT TS1 | 0.22 | 0.22 | 0.11 | 0.11 |
SPLIT TS2 | 0.22 | 0.22 | 0.11 | 0.11 |
Report: System Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:40
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 3971.75 | 7016.75 | 2913.00 |
G NW APARTMENT | 4270.50 | 7318.25 | 3466.75 |
OFFICE | 796.25 | 1656.00 | 558.50 |
G NE APARTMENT | 4210.50 | 7455.25 | 3493.75 |
G N1 APARTMENT | 3709.50 | 7574.50 | 3156.75 |
G N2 APARTMENT | 3706.50 | 7587.50 | 3162.50 |
G S1 APARTMENT | 3322.00 | 7063.50 | 2425.25 |
G S2 APARTMENT | 3548.75 | 6991.00 | 2585.75 |
M SW APARTMENT | 3604.50 | 5595.00 | 1230.75 |
M NW APARTMENT | 4260.25 | 5949.25 | 2111.00 |
M SE APARTMENT | 3545.50 | 5630.50 | 1187.25 |
M NE APARTMENT | 4194.25 | 5992.25 | 2092.00 |
M N1 APARTMENT | 3320.75 | 5872.50 | 1275.25 |
M N2 APARTMENT | 3313.75 | 5879.00 | 1273.75 |
M S1 APARTMENT | 2668.75 | 5438.50 | 333.25 |
M S2 APARTMENT | 2666.00 | 5440.50 | 333.25 |
T SW APARTMENT | 4802.50 | 6161.50 | 2890.00 |
T NW APARTMENT | 5160.75 | 6537.25 | 3485.50 |
T SE APARTMENT | 4783.75 | 6191.75 | 2887.50 |
T NE APARTMENT | 5128.75 | 6638.25 | 3520.00 |
T N1 APARTMENT | 4758.50 | 6549.75 | 3126.75 |
T N2 APARTMENT | 4757.25 | 6557.50 | 3130.00 |
T S1 APARTMENT | 4346.25 | 6052.25 | 2398.25 |
T S2 APARTMENT | 4343.75 | 6051.50 | 2399.50 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 6166.50 | 7666.75 | 3971.25 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 4.25 | 0.00 | 4.25 | 0.00 |
G NW APARTMENT | 2.50 | 0.00 | 2.50 | 0.00 |
OFFICE | 21.25 | 2.25 | 0.25 | 0.00 |
G NE APARTMENT | 3.25 | 0.00 | 3.25 | 0.00 |
G N1 APARTMENT | 1.75 | 0.75 | 1.75 | 0.75 |
G N2 APARTMENT | 2.75 | 1.00 | 2.75 | 1.00 |
G S1 APARTMENT | 0.75 | 0.00 | 0.75 | 0.00 |
G S2 APARTMENT | 3.25 | 0.00 | 3.25 | 0.00 |
M SW APARTMENT | 2.00 | 0.00 | 2.00 | 0.00 |
M NW APARTMENT | 2.00 | 0.00 | 2.00 | 0.00 |
M SE APARTMENT | 1.75 | 0.00 | 1.75 | 0.00 |
M NE APARTMENT | 3.00 | 0.00 | 3.00 | 0.00 |
M N1 APARTMENT | 0.50 | 0.00 | 0.50 | 0.00 |
M N2 APARTMENT | 1.00 | 0.00 | 1.00 | 0.00 |
M S1 APARTMENT | 1.75 | 0.00 | 1.75 | 0.00 |
M S2 APARTMENT | 1.00 | 0.00 | 1.00 | 0.00 |
T SW APARTMENT | 1.75 | 0.00 | 1.75 | 0.00 |
T NW APARTMENT | 2.00 | 0.00 | 2.00 | 0.00 |
T SE APARTMENT | 1.75 | 0.00 | 1.75 | 0.00 |
T NE APARTMENT | 2.75 | 0.00 | 2.75 | 0.00 |
T N1 APARTMENT | 1.50 | 0.00 | 1.50 | 0.00 |
T N2 APARTMENT | 1.75 | 0.00 | 1.75 | 0.00 |
T S1 APARTMENT | 1.25 | 0.00 | 1.25 | 0.00 |
T S2 APARTMENT | 2.00 | 0.00 | 2.00 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 59.00 | 3.25 | 38.00 | 1.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:40
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.365 | 0.215 | 0.000 | 0.064 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.215 | 0.000 | 0.062 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.518 | 0.246 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.215 | 0.000 | 0.061 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.130 | 0.000 | 0.061 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.130 | 0.000 | 0.061 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.130 | 0.000 | 0.064 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.130 | 0.000 | 0.064 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.309 | 0.000 | 0.079 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.309 | 0.000 | 0.076 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.309 | 0.000 | 0.079 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.309 | 0.000 | 0.076 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.186 | 0.000 | 0.076 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.186 | 0.000 | 0.076 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.187 | 0.000 | 0.079 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.187 | 0.000 | 0.079 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.409 | 0.000 | 0.092 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.409 | 0.000 | 0.088 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.409 | 0.000 | 0.092 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.408 | 0.000 | 0.088 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.246 | 0.000 | 0.088 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.246 | 0.000 | 0.088 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.247 | 0.000 | 0.092 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.247 | 0.000 | 0.092 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.499 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 1.363 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 1.363 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 1.363 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 1.363 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.363 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.363 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.363 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.363 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.341 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:40
Surfaces by ClassTotal | Outdoors | |
Wall | 126 | 42 |
Floor | 27 | 9 |
Roof | 27 | 9 |
Internal Mass | 24 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 39 | 39 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 24 |
Conditioned Zones | 24 |
Unconditioned Zones | 3 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 1385 |
Defaulted Fields | 439 |
Fields with Defaults | 3704 |
Autosized Fields | 336 |
Autosizable Fields | 454 |
Autocalculated Fields | 247 |
Autocalculatable Fields | 424 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2015-09-09 18:47:40
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 1399.27 | 19714.91 | 01-JAN-03:15 | 85847.16 | 28-JUN-18:00 |
Electricity:Building | 636.11 | 10559.61 | 01-JAN-03:15 | 31610.87 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity | 118.46 | 2466.75 | 01-JAN-00:15 | 5482.59 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 96.36 | 2205.67 | 01-JAN-00:15 | 4426.44 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 35.93 | 610.39 | 01-JAN-00:15 | 2669.36 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 26.45 | 416.15 | 01-JAN-00:15 | 2080.74 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M SW APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:T SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 144.16 | 1427.03 | 01-JAN-00:15 | 8651.76 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 14.58 | 462.39 | 01-JAN-00:15 | 462.39 | 01-JAN-00:15 |
Electricity:Zone:M CORRIDOR | 29.16 | 924.77 | 01-JAN-00:15 | 924.77 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 29.16 | 924.77 | 01-JAN-00:15 | 924.77 | 01-JAN-00:15 |
Electricity:Zone:T CORRIDOR | 14.58 | 462.39 | 01-JAN-00:15 | 462.39 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 14.58 | 462.39 | 01-JAN-00:15 | 462.39 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 22.11 | 261.08 | 01-JAN-00:15 | 1411.40 | 02-JAN-16:15 |
InteriorEquipment:Electricity | 517.65 | 8092.87 | 01-JAN-03:15 | 26730.99 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 517.65 | 8092.87 | 01-JAN-03:15 | 26730.99 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 9.48 | 194.25 | 01-JAN-00:15 | 588.62 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G CORRIDOR | 129.57 | 964.65 | 01-JAN-00:15 | 8189.37 | 01-JAN-07:15 |
Electricity:Plant | 463.66 | 0.00 | 01-JAN-00:15 | 33056.56 | 26-FEB-07:30 |
WaterSystems:Electricity | 463.66 | 0.00 | 01-JAN-00:15 | 33056.56 | 26-FEB-07:30 |
Water Heater:WaterSystems:Electricity | 463.66 | 0.00 | 01-JAN-00:15 | 33056.56 | 26-FEB-07:30 |
Fans:Electricity | 208.21 | 6602.29 | 01-JAN-08:30 | 6602.29 | 03-JAN-08:30 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 1399.27 | 19714.91 | 01-JAN-03:15 | 85847.16 | 28-JUN-18:00 |
ElectricityPurchased:Plant | 1399.27 | 19714.91 | 01-JAN-03:15 | 85847.16 | 28-JUN-18:00 |
Cogeneration:ElectricityPurchased | 1399.27 | 19714.91 | 01-JAN-03:15 | 85847.16 | 28-JUN-18:00 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 1399.27 | 19714.91 | 01-JAN-03:15 | 85847.16 | 28-JUN-18:00 |
ElectricityNet:Plant | 1399.27 | 19714.91 | 01-JAN-03:15 | 85847.16 | 28-JUN-18:00 |
Cogeneration:ElectricityNet | 1399.27 | 19714.91 | 01-JAN-03:15 | 85847.16 | 28-JUN-18:00 |
ExteriorLights:Electricity | 40.05 | 0.00 | 01-JAN-08:15 | 2553.00 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 40.05 | 0.00 | 01-JAN-08:15 | 2553.00 | 01-JAN-00:15 |
Electricity:HVAC | 259.45 | 6602.29 | 01-JAN-08:30 | 31124.09 | 16-JUL-16:00 |
General:Fans:Electricity | 208.21 | 6602.29 | 01-JAN-08:30 | 6602.29 | 03-JAN-08:30 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:Electricity | 51.24 | 0.00 | 01-JAN-00:15 | 24521.80 | 16-JUL-16:00 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 921.33 | 0.00 | 31-MAR-17:15 | 177327.73 | 19-DEC-03:00 |
Gas:HVAC | 921.33 | 0.00 | 31-MAR-17:15 | 177327.73 | 19-DEC-03:00 |
Heating:Gas | 921.33 | 0.00 | 31-MAR-17:15 | 177327.73 | 19-DEC-03:00 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 1595.45 | 1568.25 | 09-OCT-16:15 | 246893.68 | 11-JAN-12:00 |
EnergyTransfer:Building | 648.52 | 1301.13 | 11-MAY-07:00 | 106106.05 | 11-JAN-12:00 |
EnergyTransfer:Zone:G SW APARTMENT | 18.75 | 0.08 | 16-OCT-19:45 | 3292.22 | 11-JAN-12:00 |
Heating:EnergyTransfer | 425.28 | 0.00 | 10-MAR-13:45 | 106106.05 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 14.73 | 0.00 | 01-FEB-13:00 | 3292.22 | 11-JAN-12:00 |
Cooling:EnergyTransfer | 223.24 | 0.00 | 02-JAN-07:15 | 57757.41 | 16-JUL-15:15 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 4.02 | 0.00 | 01-JAN-00:15 | 1618.16 | 16-JUL-16:15 |
EnergyTransfer:Zone:G NW APARTMENT | 20.84 | 0.00 | 23-OCT-14:15 | 3372.12 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 18.00 | 0.00 | 10-MAR-13:45 | 3372.12 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 2.85 | 0.00 | 01-JAN-00:15 | 1561.15 | 25-JUN-18:00 |
EnergyTransfer:Zone:OFFICE | 20.31 | 0.00 | 09-JUN-23:00 | 5128.99 | 08-JAN-07:30 |
Heating:EnergyTransfer:Zone:OFFICE | 2.31 | 0.00 | 01-JAN-00:15 | 5128.99 | 08-JAN-07:30 |
Cooling:EnergyTransfer:Zone:OFFICE | 18.00 | 0.00 | 02-JAN-07:15 | 4122.43 | 16-JUL-10:30 |
EnergyTransfer:Zone:G NE APARTMENT | 20.75 | 0.11 | 15-JUN-14:00 | 3351.28 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 17.84 | 0.00 | 10-MAR-13:45 | 3351.28 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 2.91 | 0.00 | 01-JAN-00:15 | 1121.84 | 17-JUL-09:30 |
EnergyTransfer:Zone:G N1 APARTMENT | 13.46 | 0.01 | 06-APR-12:30 | 2060.98 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 10.57 | 0.00 | 10-MAR-13:45 | 2060.98 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 2.89 | 0.00 | 01-JAN-00:15 | 834.49 | 25-JUN-18:00 |
EnergyTransfer:Zone:G N2 APARTMENT | 13.45 | 0.07 | 07-APR-12:15 | 2059.99 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 10.57 | 0.00 | 10-MAR-13:45 | 2059.99 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 2.89 | 0.00 | 01-JAN-00:15 | 824.02 | 25-JUN-18:00 |
EnergyTransfer:Zone:G S1 APARTMENT | 11.60 | 0.06 | 22-MAY-14:30 | 1982.88 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 7.60 | 0.00 | 02-JAN-12:00 | 1982.88 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 4.00 | 0.00 | 01-JAN-00:15 | 1101.30 | 11-AUG-12:45 |
EnergyTransfer:Zone:G S2 APARTMENT | 12.61 | 0.10 | 11-MAY-10:45 | 2089.86 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 8.54 | 0.00 | 02-JAN-12:15 | 2089.86 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 4.07 | 0.00 | 01-JAN-00:15 | 1169.53 | 11-AUG-12:45 |
EnergyTransfer:Zone:M SW APARTMENT | 42.49 | 0.10 | 16-MAY-09:45 | 7721.85 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 23.80 | 0.00 | 02-JAN-13:30 | 7721.85 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 18.68 | 0.00 | 01-JAN-00:15 | 4923.56 | 25-JUN-17:30 |
EnergyTransfer:Zone:M NW APARTMENT | 45.52 | 0.03 | 01-APR-12:15 | 7750.27 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 32.10 | 0.00 | 09-FEB-15:00 | 7750.27 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 13.42 | 0.00 | 01-JAN-00:15 | 4804.66 | 25-JUN-18:00 |
EnergyTransfer:Zone:M SE APARTMENT | 41.88 | 0.00 | 23-OCT-14:15 | 7642.12 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 23.57 | 0.00 | 02-JAN-13:30 | 7642.12 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 18.32 | 0.00 | 01-JAN-00:15 | 4434.72 | 17-JUL-12:00 |
EnergyTransfer:Zone:M NE APARTMENT | 45.13 | 0.30 | 03-MAY-11:30 | 7603.23 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 31.86 | 0.00 | 09-FEB-17:00 | 7603.23 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 13.27 | 0.00 | 01-JAN-00:15 | 3677.11 | 25-JUN-18:00 |
EnergyTransfer:Zone:M N1 APARTMENT | 27.77 | 0.28 | 11-MAY-10:30 | 4530.05 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 14.15 | 0.00 | 15-JAN-18:15 | 4530.05 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 13.63 | 0.00 | 01-JAN-00:15 | 2879.24 | 25-JUN-18:30 |
EnergyTransfer:Zone:M N2 APARTMENT | 27.74 | 0.01 | 11-MAY-10:45 | 4527.05 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 14.15 | 0.00 | 15-JAN-18:15 | 4527.05 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 13.59 | 0.00 | 01-JAN-00:15 | 2861.02 | 25-JUN-18:30 |
EnergyTransfer:Zone:M S1 APARTMENT | 28.85 | 0.07 | 15-OCT-09:30 | 4310.53 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 8.17 | 0.00 | 02-JAN-10:45 | 4310.53 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 20.68 | 0.00 | 01-JAN-00:15 | 3432.12 | 11-AUG-12:45 |
EnergyTransfer:Zone:M S2 APARTMENT | 28.81 | 0.07 | 20-NOV-11:00 | 4308.35 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 8.16 | 0.00 | 02-JAN-10:45 | 4308.35 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 20.64 | 0.00 | 01-JAN-00:15 | 3445.50 | 11-AUG-12:45 |
EnergyTransfer:Zone:T SW APARTMENT | 33.40 | 0.00 | 15-JUN-01:30 | 5846.19 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 25.96 | 0.00 | 01-FEB-12:45 | 5846.19 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 7.44 | 0.00 | 01-JAN-00:15 | 3225.61 | 25-JUN-16:15 |
EnergyTransfer:Zone:T NW APARTMENT | 35.79 | 0.01 | 31-AUG-01:30 | 5859.09 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 30.42 | 0.00 | 09-FEB-16:15 | 5859.09 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 5.37 | 0.00 | 01-JAN-00:15 | 3086.84 | 25-JUN-18:00 |
EnergyTransfer:Zone:T SE APARTMENT | 32.85 | 0.01 | 30-MAR-23:00 | 5803.90 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 25.73 | 0.00 | 01-FEB-12:30 | 5803.90 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 7.12 | 0.00 | 01-JAN-00:15 | 3025.20 | 17-JUL-12:00 |
EnergyTransfer:Zone:T NE APARTMENT | 35.39 | 0.05 | 17-AUG-01:45 | 5775.44 | 11-JAN-12:00 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 30.18 | 0.00 | 10-MAR-11:00 | 5775.44 | 11-JAN-12:00 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 5.21 | 0.00 | 01-JAN-00:15 | 2412.43 | 25-JUN-16:30 |
EnergyTransfer:Zone:T N1 APARTMENT | 23.76 | 0.10 | 11-OCT-13:00 | 3947.28 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 18.78 | 0.00 | 11-FEB-13:00 | 3947.28 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 4.98 | 0.00 | 01-JAN-00:15 | 1940.84 | 25-JUN-18:15 |
EnergyTransfer:Zone:T N2 APARTMENT | 23.75 | 0.01 | 15-AUG-12:00 | 3946.95 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 18.79 | 0.00 | 11-FEB-13:00 | 3946.95 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 4.96 | 0.00 | 01-JAN-00:15 | 1932.91 | 25-JUN-18:00 |
EnergyTransfer:Zone:T S1 APARTMENT | 21.81 | 0.01 | 08-MAY-22:30 | 3879.78 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 14.65 | 0.00 | 02-JAN-12:15 | 3879.78 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 7.16 | 0.00 | 01-JAN-00:15 | 2432.62 | 17-JUL-14:00 |
EnergyTransfer:Zone:T S2 APARTMENT | 21.81 | 0.04 | 13-JUL-08:00 | 3879.83 | 19-DEC-03:00 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 14.65 | 0.00 | 02-JAN-12:15 | 3879.83 | 19-DEC-03:00 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 7.16 | 0.00 | 01-JAN-00:15 | 2441.57 | 17-JUL-13:45 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:HVAC | 946.93 | 0.00 | 16-APR-20:15 | 141862.19 | 19-DEC-03:00 |
HeatingCoils:EnergyTransfer | 737.07 | 0.00 | 31-MAR-17:15 | 141862.19 | 19-DEC-03:00 |
CoolingCoils:EnergyTransfer | 209.86 | 0.00 | 01-JAN-00:15 | 100471.93 | 16-JUL-16:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:40
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 14.731 | -4.019 | 0.000 | 0.000 | 3.926 | 1.087 | 12.213 | 11.669 | 0.000 | 0.044 | 0.000 | 0.000 | -9.885 | 0.000 | -12.097 | -17.667 |
G NW APARTMENT | 17.996 | -2.846 | 0.000 | 0.000 | 3.939 | 1.087 | 12.213 | 5.492 | 0.000 | 0.043 | 0.000 | 0.000 | -10.735 | 0.000 | -12.001 | -15.189 |
OFFICE | 2.312 | -17.999 | 0.000 | 0.000 | 0.541 | 26.452 | 9.482 | 11.365 | 0.000 | 0.026 | 0.000 | 0.000 | -9.237 | 0.000 | -10.705 | -12.237 |
G NE APARTMENT | 17.844 | -2.907 | 0.000 | 0.000 | 3.951 | 1.087 | 12.213 | 5.137 | 0.000 | 0.043 | 0.000 | 0.000 | -10.514 | 0.000 | -11.980 | -14.873 |
G N1 APARTMENT | 10.569 | -2.888 | 0.000 | 0.000 | 3.946 | 1.087 | 12.213 | 1.779 | 0.000 | 0.031 | 0.000 | 0.000 | -6.788 | 0.000 | -7.500 | -12.449 |
G N2 APARTMENT | 10.566 | -2.888 | 0.000 | 0.000 | 3.947 | 1.087 | 12.213 | 1.779 | 0.000 | 0.031 | 0.000 | 0.000 | -6.787 | 0.000 | -7.498 | -12.450 |
G S1 APARTMENT | 7.599 | -4.003 | 0.000 | 0.000 | 3.924 | 1.087 | 12.213 | 8.052 | 0.000 | 0.030 | 0.000 | 0.000 | -5.997 | 0.000 | -7.610 | -15.295 |
G S2 APARTMENT | 8.535 | -4.073 | 0.000 | 0.000 | 3.921 | 1.087 | 12.213 | 8.051 | 0.000 | 0.030 | 0.000 | 0.000 | -5.989 | 0.000 | -7.619 | -16.157 |
M SW APARTMENT | 23.804 | -18.682 | 0.000 | 0.000 | 3.845 | 1.087 | 12.213 | 11.274 | 0.000 | 0.061 | 0.000 | 0.000 | -10.481 | 0.000 | -17.525 | -5.595 |
M NW APARTMENT | 32.105 | -13.419 | 0.000 | 0.000 | 3.871 | 1.087 | 12.213 | 5.191 | 0.000 | 0.061 | 0.000 | 0.000 | -11.310 | 0.000 | -17.366 | -12.431 |
M SE APARTMENT | 23.569 | -18.315 | 0.000 | 0.000 | 3.850 | 1.087 | 12.213 | 10.986 | 0.000 | 0.061 | 0.001 | 0.000 | -10.328 | 0.000 | -17.520 | -5.601 |
M NE APARTMENT | 31.859 | -13.271 | 0.000 | 0.000 | 3.880 | 1.087 | 12.213 | 4.834 | 0.000 | 0.061 | 0.000 | 0.000 | -11.074 | 0.000 | -17.343 | -12.244 |
M N1 APARTMENT | 14.149 | -13.625 | 0.000 | 0.000 | 3.867 | 1.087 | 12.213 | 1.598 | 0.000 | 0.042 | 0.000 | 0.000 | -7.203 | 0.000 | -10.870 | -1.257 |
M N2 APARTMENT | 14.148 | -13.589 | 0.000 | 0.000 | 3.867 | 1.087 | 12.213 | 1.599 | 0.000 | 0.042 | 0.001 | 0.000 | -7.201 | 0.000 | -10.868 | -1.296 |
M S1 APARTMENT | 8.174 | -20.678 | 0.000 | 0.000 | 3.829 | 1.087 | 12.213 | 7.801 | 0.000 | 0.042 | 4.939 | 0.000 | -6.388 | 0.000 | -11.019 | -0.000 |
M S2 APARTMENT | 8.165 | -20.642 | 0.000 | 0.000 | 3.830 | 1.087 | 12.213 | 7.801 | 0.000 | 0.042 | 4.912 | 0.000 | -6.387 | 0.000 | -11.020 | -0.000 |
T SW APARTMENT | 25.958 | -7.441 | 0.000 | 0.000 | 3.890 | 1.087 | 12.213 | 11.209 | 0.000 | 0.081 | 0.000 | 0.000 | -10.102 | 0.000 | -22.800 | -14.094 |
T NW APARTMENT | 30.422 | -5.369 | 0.000 | 0.000 | 3.910 | 1.087 | 12.213 | 5.170 | 0.000 | 0.080 | 0.000 | 0.000 | -10.947 | 0.000 | -22.602 | -13.964 |
T SE APARTMENT | 25.728 | -7.121 | 0.000 | 0.000 | 3.896 | 1.087 | 12.213 | 10.939 | 0.000 | 0.081 | 0.000 | 0.000 | -9.964 | 0.000 | -22.806 | -14.052 |
T NE APARTMENT | 30.183 | -5.206 | 0.000 | 0.000 | 3.923 | 1.087 | 12.213 | 4.829 | 0.000 | 0.080 | 0.000 | 0.000 | -10.718 | 0.000 | -22.581 | -13.809 |
T N1 APARTMENT | 18.783 | -4.979 | 0.000 | 0.000 | 3.911 | 1.087 | 12.213 | 1.615 | 0.000 | 0.056 | 0.000 | 0.000 | -6.941 | 0.000 | -14.043 | -11.700 |
T N2 APARTMENT | 18.787 | -4.959 | 0.000 | 0.000 | 3.911 | 1.087 | 12.213 | 1.614 | 0.000 | 0.056 | 0.000 | 0.000 | -6.939 | 0.000 | -14.044 | -11.726 |
T S1 APARTMENT | 14.647 | -7.160 | 0.000 | 0.000 | 3.878 | 1.087 | 12.213 | 7.773 | 0.000 | 0.056 | 0.000 | 0.000 | -6.160 | 0.000 | -14.241 | -12.094 |
T S2 APARTMENT | 14.650 | -7.155 | 0.000 | 0.000 | 3.879 | 1.087 | 12.213 | 7.772 | 0.000 | 0.056 | 0.000 | 0.000 | -6.158 | 0.000 | -14.242 | -12.101 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 14.582 | 0.000 | 0.049 | 0.000 | 0.002 | 0.000 | 0.000 | -1.291 | 0.000 | -3.772 | -9.569 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 14.582 | 6.479 | 0.199 | 0.000 | 0.081 | 27.854 | 0.000 | -3.331 | 0.000 | -45.863 | -0.000 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 14.582 | 0.000 | 0.048 | 0.000 | 0.002 | 0.000 | 0.000 | -1.385 | 0.000 | -3.056 | -10.191 |
Total Facility | 425.282 | -223.235 | 0.000 | 0.000 | 90.131 | 95.189 | 296.854 | 155.626 | 0.000 | 1.322 | 37.706 | 0.000 | -210.240 | 0.000 | -390.591 | -278.043 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 16-JUL-16:05 | 0.00 | -1621.89 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 1627.40 | 0.00 | 178.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -921.87 |
G NW APARTMENT | 25-JUN-18:00 | 0.00 | -1560.82 | 0.00 | 0.00 | 141.83 | 87.56 | 588.62 | 1874.63 | 0.00 | 218.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1350.65 |
OFFICE | 23-JUL-06:01 | 0.00 | -7124.37 | 0.00 | 0.00 | 0.00 | 416.15 | 294.31 | 1101.14 | 0.00 | 0.00 | 5589.20 | 0.00 | 0.00 | 0.00 | -276.44 | 0.00 |
G NE APARTMENT | 17-JUL-09:30 | 0.00 | -1121.48 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 1724.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1062.62 |
G N1 APARTMENT | 25-JUN-18:00 | 0.00 | -834.30 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 528.24 | 0.00 | 131.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -643.93 |
G N2 APARTMENT | 25-JUN-18:00 | 0.00 | -823.83 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 528.45 | 0.00 | 131.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -654.60 |
G S1 APARTMENT | 11-AUG-12:45 | 0.00 | -1101.20 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 1788.20 | 0.00 | 70.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1199.70 |
G S2 APARTMENT | 11-AUG-12:45 | 0.00 | -1169.43 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 1787.22 | 0.00 | 70.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1130.50 |
M SW APARTMENT | 25-JUN-17:23 | 0.00 | -4923.39 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 1703.62 | 0.00 | 309.72 | 2092.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NW APARTMENT | 25-JUN-18:00 | 0.00 | -4803.86 | 0.00 | 0.00 | 141.83 | 87.56 | 588.62 | 1851.99 | 0.00 | 313.48 | 1820.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M SE APARTMENT | 17-JUL-12:00 | 0.00 | -4436.34 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 1720.53 | 0.00 | 195.54 | 2060.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NE APARTMENT | 25-JUN-18:00 | 0.00 | -3676.56 | 0.00 | 0.00 | 141.83 | 87.56 | 588.62 | 653.29 | 0.00 | 313.47 | 1891.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N1 APARTMENT | 25-JUN-18:30 | 0.00 | -2878.71 | 0.00 | 0.00 | 141.56 | 103.77 | 547.42 | 612.38 | 0.00 | 129.38 | 1344.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 25-JUN-18:30 | 0.00 | -2860.49 | 0.00 | 0.00 | 141.53 | 103.77 | 547.42 | 612.49 | 0.00 | 129.37 | 1325.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | 11-AUG-12:45 | 0.00 | -3431.88 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 1776.78 | 0.00 | 90.95 | 1121.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S2 APARTMENT | 11-AUG-12:45 | 0.00 | -3445.26 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 1776.71 | 0.00 | 90.95 | 1135.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SW APARTMENT | 25-JUN-16:06 | 0.00 | -3230.61 | 0.00 | 0.00 | 84.78 | 64.86 | 588.62 | 1745.15 | 0.00 | 463.53 | 283.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 25-JUN-18:00 | 0.00 | -3086.43 | 0.00 | 0.00 | 141.84 | 87.56 | 588.62 | 1822.53 | 0.00 | 412.04 | 33.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SE APARTMENT | 17-JUL-12:00 | 0.00 | -3026.38 | 0.00 | 0.00 | 40.75 | 12.97 | 406.15 | 1687.38 | 0.00 | 257.24 | 621.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 25-JUN-16:15 | 0.00 | -2415.94 | 0.00 | 0.00 | 84.55 | 64.86 | 588.62 | 653.16 | 0.00 | 459.98 | 564.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 25-JUN-18:15 | 0.00 | -1940.54 | 0.00 | 0.00 | 141.33 | 103.77 | 547.42 | 553.28 | 0.00 | 207.07 | 387.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 25-JUN-18:00 | 0.00 | -1932.65 | 0.00 | 0.00 | 141.65 | 87.56 | 588.62 | 505.73 | 0.00 | 248.01 | 361.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 17-JUL-13:45 | 0.00 | -2432.12 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1184.42 | 0.00 | 103.28 | 708.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S2 APARTMENT | 17-JUL-13:45 | 0.00 | -2441.11 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1184.30 | 0.00 | 103.28 | 717.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 16-JUL-15:15 | 0.00 | -57763.14 | 0.00 | 0.00 | 1192.08 | 4512.09 | 11708.34 | 23043.79 | 0.00 | 5503.98 | 11802.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 11-JAN-12:00 | 3292.08 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -652.03 | 0.00 | -2345.43 | -767.05 |
G NW APARTMENT | 11-JAN-12:00 | 3371.98 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -757.22 | 0.00 | -2345.43 | -741.77 |
OFFICE | 18-APR-06:01 | 7152.67 | 0.00 | 0.00 | 0.00 | 0.00 | 416.15 | 294.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -492.96 | 0.00 | -574.82 | -6795.34 |
G NE APARTMENT | 19-DEC-03:00 | 3351.26 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1116.08 | 0.00 | -2083.75 | -577.14 |
G N1 APARTMENT | 11-JAN-12:00 | 2060.86 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -459.85 | 0.00 | -1414.70 | -658.73 |
G N2 APARTMENT | 11-JAN-12:00 | 2059.87 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -459.87 | 0.00 | -1414.70 | -657.72 |
G S1 APARTMENT | 11-JAN-12:00 | 1982.76 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -354.74 | 0.00 | -1414.70 | -685.74 |
G S2 APARTMENT | 19-DEC-03:00 | 2089.85 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -663.72 | 0.00 | -1256.87 | -594.99 |
M SW APARTMENT | 11-JAN-12:00 | 7721.59 | 0.00 | 0.00 | 0.00 | 47.48 | 12.97 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -684.53 | 0.00 | -3365.28 | -4144.27 |
M NW APARTMENT | 11-JAN-12:00 | 7750.03 | 0.00 | 0.00 | 0.00 | 47.69 | 12.97 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -786.89 | 0.00 | -3355.30 | -4080.53 |
M SE APARTMENT | 11-JAN-12:00 | 7641.88 | 0.00 | 0.00 | 0.00 | 47.48 | 12.97 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -658.95 | 0.00 | -3365.10 | -4090.32 |
M NE APARTMENT | 11-JAN-12:00 | 7603.03 | 0.00 | 0.00 | 0.00 | 47.80 | 12.97 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -760.77 | 0.00 | -3351.13 | -3963.93 |
M N1 APARTMENT | 11-JAN-12:00 | 4529.83 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -480.95 | 0.00 | -2033.82 | -2487.48 |
M N2 APARTMENT | 11-JAN-12:00 | 4526.84 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -480.97 | 0.00 | -2033.80 | -2484.50 |
M S1 APARTMENT | 11-JAN-12:00 | 4310.31 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -375.55 | 0.00 | -2034.00 | -2373.19 |
M S2 APARTMENT | 11-JAN-12:00 | 4308.13 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -375.57 | 0.00 | -2034.00 | -2370.99 |
T SW APARTMENT | 11-JAN-12:00 | 5846.05 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -674.51 | 0.00 | -4464.03 | -1179.93 |
T NW APARTMENT | 11-JAN-12:00 | 5858.95 | 0.00 | 0.00 | 0.00 | 47.46 | 12.97 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -777.01 | 0.00 | -4455.63 | -1098.78 |
T SE APARTMENT | 11-JAN-12:00 | 5803.76 | 0.00 | 0.00 | 0.00 | 47.42 | 12.97 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -648.02 | 0.00 | -4464.39 | -1163.78 |
T NE APARTMENT | 11-JAN-12:00 | 5775.34 | 0.00 | 0.00 | 0.00 | 47.51 | 12.97 | 412.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -750.30 | 0.00 | -4450.93 | -1046.63 |
T N1 APARTMENT | 19-DEC-03:00 | 3947.26 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -691.92 | 0.00 | -2390.82 | -1290.24 |
T N2 APARTMENT | 19-DEC-03:00 | 3946.93 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -691.92 | 0.00 | -2390.78 | -1289.95 |
T S1 APARTMENT | 19-DEC-03:00 | 3879.76 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -666.22 | 0.00 | -2392.32 | -1246.94 |
T S2 APARTMENT | 19-DEC-03:00 | 3879.81 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 229.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -666.22 | 0.00 | -2392.32 | -1246.99 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 11-JAN-12:00 | 106102.19 | 0.00 | 0.00 | 0.00 | 1169.51 | 3766.23 | 10193.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -13949.83 | 0.00 | -70266.35 | -37015.71 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:40
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:40
Sec1.1A-General InformationData | |
Weather File | Duluth International Arpt MN USA TMY3 WMO#=727450 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 3134.61 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.32 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 3134.61 | 2823.98 | 310.64 |
Data | |
Number of hours heating loads not met | 38.00 |
Number of hours cooling loads not met | 1.00 |
Number of hours not met | 39.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 118.46 | 4979.95 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 40.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 0.00 | 0.00 | 921.33 | 177327.73 | 0.00 | 0.00 |
Space Cooling | 51.24 | 17033.20 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 208.21 | 6602.29 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 463.66 | 30600.80 | 0.00 | 0.00 | 0.00 | 0.00 |
Receptacle Equipment | 517.65 | 26630.92 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 1399.27 | 921.33 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 517.65 | 1399.27 |
Natural Gas | 0.00 | 921.33 |
Additional | 0.00 | 0.00 |
Total | 517.65 | 2320.61 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 37.79 |
Space Heating | 0.00 |
Space Cooling | 16.35 |
Fans-Interior | 66.42 |
Service Water Heating | 147.92 |
Receptacle Equipment | 165.14 |
Miscellaneous | 12.78 |
Subtotal | 446.39 |
Natural Gas [MJ/m2] | |
Space Heating | 293.92 |
Service Water Heating | 0.00 |
Miscellaneous | 0.00 |
Subtotal | 293.92 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 5.10 |
Space Heating | 39.70 |
Space Cooling | 2.21 |
Fans-Interior | 8.97 |
Service Water Heating | 19.98 |
Receptacle Equipment | 22.31 |
Miscellaneous | 1.73 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:40
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.151917 |
G NW APARTMENT DIRECT AIR | 0.139601 |
OFFICE DIRECT AIR | 0.465142 |
G NE APARTMENT DIRECT AIR | 0.102240 |
G N1 APARTMENT DIRECT AIR | 0.075635 |
G N2 APARTMENT DIRECT AIR | 0.074510 |
G S1 APARTMENT DIRECT AIR | 0.100014 |
G S2 APARTMENT DIRECT AIR | 0.103467 |
M SW APARTMENT DIRECT AIR | 0.446812 |
M NW APARTMENT DIRECT AIR | 0.407749 |
M SE APARTMENT DIRECT AIR | 0.409824 |
M NE APARTMENT DIRECT AIR | 0.315004 |
M N1 APARTMENT DIRECT AIR | 0.243049 |
M N2 APARTMENT DIRECT AIR | 0.241072 |
M S1 APARTMENT DIRECT AIR | 0.312197 |
M S2 APARTMENT DIRECT AIR | 0.313571 |
T SW APARTMENT DIRECT AIR | 0.292044 |
T NW APARTMENT DIRECT AIR | 0.259062 |
T SE APARTMENT DIRECT AIR | 0.272529 |
T NE APARTMENT DIRECT AIR | 0.201892 |
T N1 APARTMENT DIRECT AIR | 0.156230 |
T N2 APARTMENT DIRECT AIR | 0.156247 |
T S1 APARTMENT DIRECT AIR | 0.223382 |
T S2 APARTMENT DIRECT AIR | 0.224325 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW MAIN BRANCH | 0.151917 |
SPLIT GNW MAIN BRANCH | 0.139601 |
SPLIT OFFICE MAIN BRANCH | 0.465142 |
SPLIT GNE MAIN BRANCH | 0.102240 |
SPLIT GN1 MAIN BRANCH | 0.075635 |
SPLIT GN2 MAIN BRANCH | 0.074510 |
SPLIT GS1 MAIN BRANCH | 0.100014 |
SPLIT GS2 MAIN BRANCH | 0.103467 |
SPLIT MSW MAIN BRANCH | 0.446812 |
SPLIT MNW MAIN BRANCH | 0.407749 |
SPLIT MSE MAIN BRANCH | 0.409824 |
SPLIT MNE MAIN BRANCH | 0.315004 |
SPLIT MN1 MAIN BRANCH | 0.243049 |
SPLIT MN2 MAIN BRANCH | 0.241072 |
SPLIT MS1 MAIN BRANCH | 0.312197 |
SPLIT MS2 MAIN BRANCH | 0.313571 |
SPLIT TSW MAIN BRANCH | 0.292044 |
SPLIT TNW MAIN BRANCH | 0.259062 |
SPLIT TSE MAIN BRANCH | 0.272529 |
SPLIT TNE MAIN BRANCH | 0.201892 |
SPLIT TN1 MAIN BRANCH | 0.156230 |
SPLIT TN2 MAIN BRANCH | 0.156247 |
SPLIT TS1 MAIN BRANCH | 0.223382 |
SPLIT TS2 MAIN BRANCH | 0.224325 |
Design Supply Air Flow Rate [m3/s] | |
SPLIT GSW | 0.151917 |
SPLIT GNW | 0.139601 |
SPLIT OFFICE | 0.465142 |
SPLIT GNE | 0.102240 |
SPLIT GN1 | 0.075635 |
SPLIT GN2 | 0.074510 |
SPLIT GS1 | 0.100014 |
SPLIT GS2 | 0.103467 |
SPLIT MSW | 0.446812 |
SPLIT MNW | 0.407749 |
SPLIT MSE | 0.409824 |
SPLIT MNE | 0.315004 |
SPLIT MN1 | 0.243049 |
SPLIT MN2 | 0.241072 |
SPLIT MS1 | 0.312197 |
SPLIT MS2 | 0.313571 |
SPLIT TSW | 0.292044 |
SPLIT TNW | 0.259062 |
SPLIT TSE | 0.272529 |
SPLIT TNE | 0.201892 |
SPLIT TN1 | 0.156230 |
SPLIT TN2 | 0.156247 |
SPLIT TS1 | 0.223382 |
SPLIT TS2 | 0.224325 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
SPLIT GSW OA CONTROLLER | 0.151917 | 0.026898 |
SPLIT GNW OA CONTROLLER | 0.139601 | 0.025953 |
SPLIT OFFICE OA CONTROLLER | 0.465142 | 0.038104 |
SPLIT GNE OA CONTROLLER | 0.102240 | 0.025953 |
SPLIT GN1 OA CONTROLLER | 0.075635 | 0.025953 |
SPLIT GN2 OA CONTROLLER | 0.074510 | 0.025953 |
SPLIT GS1 OA CONTROLLER | 0.100014 | 0.025953 |
SPLIT GS2 OA CONTROLLER | 0.103467 | 0.025953 |
SPLIT MSW OA CONTROLLER | 0.446812 | 0.051906 |
SPLIT MNW OA CONTROLLER | 0.407749 | 0.051906 |
SPLIT MSE OA CONTROLLER | 0.409824 | 0.051906 |
SPLIT MNE OA CONTROLLER | 0.315004 | 0.051906 |
SPLIT MN1 OA CONTROLLER | 0.243049 | 0.051906 |
SPLIT MN2 OA CONTROLLER | 0.241072 | 0.051906 |
SPLIT MS1 OA CONTROLLER | 0.312197 | 0.051906 |
SPLIT MS2 OA CONTROLLER | 0.313571 | 0.051906 |
SPLIT TSW OA CONTROLLER | 0.292044 | 0.025953 |
SPLIT TNW OA CONTROLLER | 0.259062 | 0.025953 |
SPLIT TSE OA CONTROLLER | 0.272529 | 0.025953 |
SPLIT TNE OA CONTROLLER | 0.201892 | 0.025953 |
SPLIT TN1 OA CONTROLLER | 0.156230 | 0.025953 |
SPLIT TN2 OA CONTROLLER | 0.156247 | 0.025953 |
SPLIT TS1 OA CONTROLLER | 0.223382 | 0.025953 |
SPLIT TS2 OA CONTROLLER | 0.224325 | 0.025953 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity (gross) [W] | Rated Sensible Heat Ratio | |
SPLIT GSW COOLING COIL | 0.151917 | 2836.41 | 0.756964 |
SPLIT GNW COOLING COIL | 0.139601 | 2623.54 | 0.754843 |
SPLIT OFFICE COOLING COIL | 0.465142 | 7699.75 | 0.798655 |
SPLIT GNE COOLING COIL | 0.102240 | 2057.81 | 0.733377 |
SPLIT GN1 COOLING COIL | 0.075635 | 1556.86 | 0.726668 |
SPLIT GN2 COOLING COIL | 0.074510 | 1538.85 | 0.725680 |
SPLIT GS1 COOLING COIL | 0.100014 | 2050.66 | 0.727823 |
SPLIT GS2 COOLING COIL | 0.103467 | 2099.60 | 0.730915 |
SPLIT MSW COOLING COIL | 0.446812 | 7946.89 | 0.773184 |
SPLIT MNW COOLING COIL | 0.407749 | 7324.81 | 0.769789 |
SPLIT MSE COOLING COIL | 0.409824 | 7560.72 | 0.760888 |
SPLIT MNE COOLING COIL | 0.315004 | 5870.72 | 0.757555 |
SPLIT MN1 COOLING COIL | 0.243049 | 4591.43 | 0.753165 |
SPLIT MN2 COOLING COIL | 0.241072 | 4561.02 | 0.752674 |
SPLIT MS1 COOLING COIL | 0.312197 | 5898.60 | 0.753116 |
SPLIT MS2 COOLING COIL | 0.313571 | 5919.29 | 0.753402 |
SPLIT TSW COOLING COIL | 0.292044 | 5169.68 | 0.774808 |
SPLIT TNW COOLING COIL | 0.259062 | 4588.20 | 0.774631 |
SPLIT TSE COOLING COIL | 0.272529 | 4894.68 | 0.769860 |
SPLIT TNE COOLING COIL | 0.201892 | 3819.29 | 0.752713 |
SPLIT TN1 COOLING COIL | 0.156230 | 2993.03 | 0.748676 |
SPLIT TN2 COOLING COIL | 0.156247 | 3000.58 | 0.747913 |
SPLIT TS1 COOLING COIL | 0.223382 | 4024.69 | 0.768791 |
SPLIT TS2 COOLING COIL | 0.224325 | 4038.78 | 0.769033 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
SPLIT GSW FURNACE WITH DX COOLING | 0.151917 | 0.151917 | 0.151917 | 0.151917 | 4869.23 | 2836.41 | 1.00 |
SPLIT GNW FURNACE WITH DX COOLING | 0.139601 | 0.139601 | 0.139601 | 0.139601 | 4839.39 | 2623.54 | 1.00 |
SPLIT OFFICE FURNACE WITH DX COOLING | 0.465142 | 0.465142 | 0.465142 | 0.465142 | 7734.25 | 7699.75 | 1.00 |
SPLIT GNE FURNACE WITH DX COOLING | 0.102240 | 0.102240 | 0.102240 | 0.102240 | 4825.90 | 2057.81 | 1.00 |
SPLIT GN1 FURNACE WITH DX COOLING | 0.075635 | 0.075635 | 0.075635 | 0.075635 | 3678.62 | 1556.86 | 1.00 |
SPLIT GN2 FURNACE WITH DX COOLING | 0.074510 | 0.074510 | 0.074510 | 0.074510 | 3678.32 | 1538.85 | 1.00 |
SPLIT GS1 FURNACE WITH DX COOLING | 0.100014 | 0.100014 | 0.100014 | 0.100014 | 3657.29 | 2050.66 | 1.00 |
SPLIT GS2 FURNACE WITH DX COOLING | 0.103467 | 0.103467 | 0.103467 | 0.103467 | 3794.38 | 2099.60 | 1.00 |
SPLIT MSW FURNACE WITH DX COOLING | 0.446812 | 0.446812 | 0.446812 | 0.446812 | 9724.61 | 7946.89 | 1.00 |
SPLIT MNW FURNACE WITH DX COOLING | 0.407749 | 0.407749 | 0.407749 | 0.407749 | 9781.53 | 7324.81 | 1.00 |
SPLIT MSE FURNACE WITH DX COOLING | 0.409824 | 0.409824 | 0.409824 | 0.409824 | 9689.57 | 7560.72 | 1.00 |
SPLIT MNE FURNACE WITH DX COOLING | 0.315004 | 0.315004 | 0.315004 | 0.315004 | 9746.46 | 5870.72 | 1.00 |
SPLIT MN1 FURNACE WITH DX COOLING | 0.243049 | 0.243049 | 0.243049 | 0.243049 | 6801.41 | 4591.43 | 1.00 |
SPLIT MN2 FURNACE WITH DX COOLING | 0.241072 | 0.241072 | 0.241072 | 0.241072 | 6800.57 | 4561.02 | 1.00 |
SPLIT MS1 FURNACE WITH DX COOLING | 0.312197 | 0.312197 | 0.312197 | 0.312197 | 6747.17 | 5898.60 | 1.00 |
SPLIT MS2 FURNACE WITH DX COOLING | 0.313571 | 0.313571 | 0.313571 | 0.313571 | 6746.34 | 5919.29 | 1.00 |
SPLIT TSW FURNACE WITH DX COOLING | 0.292044 | 0.292044 | 0.292044 | 0.292044 | 6783.04 | 5169.68 | 1.00 |
SPLIT TNW FURNACE WITH DX COOLING | 0.259062 | 0.259062 | 0.259062 | 0.259062 | 6814.92 | 4588.20 | 1.00 |
SPLIT TSE FURNACE WITH DX COOLING | 0.272529 | 0.272529 | 0.272529 | 0.272529 | 6764.56 | 4894.68 | 1.00 |
SPLIT TNE FURNACE WITH DX COOLING | 0.201892 | 0.201892 | 0.201892 | 0.201892 | 6796.43 | 3819.29 | 1.00 |
SPLIT TN1 FURNACE WITH DX COOLING | 0.156230 | 0.156230 | 0.156230 | 0.156230 | 5121.17 | 2993.03 | 1.00 |
SPLIT TN2 FURNACE WITH DX COOLING | 0.156247 | 0.156247 | 0.156247 | 0.156247 | 5120.70 | 3000.58 | 1.00 |
SPLIT TS1 FURNACE WITH DX COOLING | 0.223382 | 0.223382 | 0.223382 | 0.223382 | 5087.63 | 4024.69 | 1.00 |
SPLIT TS2 FURNACE WITH DX COOLING | 0.224325 | 0.224325 | 0.224325 | 0.224325 | 5087.16 | 4038.78 | 1.00 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW SUPPLY FAN | 0.151917 |
SPLIT GNW SUPPLY FAN | 0.139601 |
SPLIT OFFICE SUPPLY FAN | 0.465142 |
SPLIT GNE SUPPLY FAN | 0.102240 |
SPLIT GN1 SUPPLY FAN | 0.075635 |
SPLIT GN2 SUPPLY FAN | 0.074510 |
SPLIT GS1 SUPPLY FAN | 0.100014 |
SPLIT GS2 SUPPLY FAN | 0.103467 |
SPLIT MSW SUPPLY FAN | 0.446812 |
SPLIT MNW SUPPLY FAN | 0.407749 |
SPLIT MSE SUPPLY FAN | 0.409824 |
SPLIT MNE SUPPLY FAN | 0.315004 |
SPLIT MN1 SUPPLY FAN | 0.243049 |
SPLIT MN2 SUPPLY FAN | 0.241072 |
SPLIT MS1 SUPPLY FAN | 0.312197 |
SPLIT MS2 SUPPLY FAN | 0.313571 |
SPLIT TSW SUPPLY FAN | 0.292044 |
SPLIT TNW SUPPLY FAN | 0.259062 |
SPLIT TSE SUPPLY FAN | 0.272529 |
SPLIT TNE SUPPLY FAN | 0.201892 |
SPLIT TN1 SUPPLY FAN | 0.156230 |
SPLIT TN2 SUPPLY FAN | 0.156247 |
SPLIT TS1 SUPPLY FAN | 0.223382 |
SPLIT TS2 SUPPLY FAN | 0.224325 |
Nominal Capacity [W] | |
SPLIT GSW HEATING COIL | 4869.23 |
SPLIT GNW HEATING COIL | 4839.39 |
SPLIT OFFICE HEATING COIL | 7734.25 |
SPLIT GNE HEATING COIL | 4825.90 |
SPLIT GN1 HEATING COIL | 3678.62 |
SPLIT GN2 HEATING COIL | 3678.32 |
SPLIT GS1 HEATING COIL | 3657.29 |
SPLIT GS2 HEATING COIL | 3794.38 |
SPLIT MSW HEATING COIL | 9724.61 |
SPLIT MNW HEATING COIL | 9781.53 |
SPLIT MSE HEATING COIL | 9689.57 |
SPLIT MNE HEATING COIL | 9746.46 |
SPLIT MN1 HEATING COIL | 6801.41 |
SPLIT MN2 HEATING COIL | 6800.57 |
SPLIT MS1 HEATING COIL | 6747.17 |
SPLIT MS2 HEATING COIL | 6746.34 |
SPLIT TSW HEATING COIL | 6783.04 |
SPLIT TNW HEATING COIL | 6814.92 |
SPLIT TSE HEATING COIL | 6764.56 |
SPLIT TNE HEATING COIL | 6796.43 |
SPLIT TN1 HEATING COIL | 5121.17 |
SPLIT TN2 HEATING COIL | 5120.70 |
SPLIT TS1 HEATING COIL | 5087.63 |
SPLIT TS2 HEATING COIL | 5087.16 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:40
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW1 S SWA | |
G WWALL SWA | GWINDOW1 W SWA | |
G NWALL NWA | GWINDOW1 N NWA | |
G WWALL NWA | GWINDOW1 W NWA | |
G SWALL SEA | GWINDOW1 S SEA | |
G EWALL SEA | GWINDOW1 E SEA | |
G NWALL NEA | GWINDOW1 N NEA | |
G EWALL NEA | GWINDOW1 E NEA | |
G NWALL N1A | GWINDOW1 N N1A | |
G NWALL N2A | GWINDOW1 N N2A | |
G SWALL S1A | GWINDOW1 S S1A | |
G SWALL S2A | GWINDOW1 S S2A | |
M WWALL SWA | MWINDOW1 W SWA | |
M SWALL SWA | MWINDOW1 S SWA | |
M NWALL NWA | MWINDOW1 N NWA | |
M WWALL NWA | MWINDOW1 W NWA | |
M EWALL SEA | MWINDOW1 E SEA | |
M SWALL SEA | MWINDOW1 S SEA | |
M NWALL NEA | MWINDOW1 N NEA | |
M EWALL NEA | MWINDOW1 E NEA | |
M NWALL N1A | MWINDOW1 N N1A | |
M NWALL N2A | MWINDOW1 N N2A | |
M SWALL S1A | MWINDOW1 S S1A | |
M SWALL S2A | MWINDOW1 S S2A | |
T WWALL SWA | TWINDOW1 W SWA | |
T SWALL SWA | TWINDOW1 S SWA | |
T NWALL NWA | TWINDOW1 N NWA | |
T WWALL NWA | TWINDOW1 W NWA | |
T EWALL SEA | TWINDOW1 E SEA | |
T SWALL SEA | TWINDOW1 S SEA | |
T NWALL NEA | TWINDOW1 N NEA | |
T EWALL NEA | TWINDOW1 E NEA | |
T NWALL N1A | TWINDOW1 N N1A | |
T NWALL N2A | TWINDOW1 N N2A | |
T SWALL S1A | TWINDOW1 S S1A | |
T SWALL S2A | TWINDOW1 S S2A | |
T EWALL C | TWINDOW14 | |
G EWALL C | ENTRANCE DOOR | |
M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:40
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.74 | -2.6 |
April | 21.88 | 4.03 |
May | 22.61 | 12.37 |
June | 23.69 | 16.19 |
July | 24.07 | 17.83 |
August | 24.14 | 17.50 |
September | 23.43 | 12.89 |
October | 21.93 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.53 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.14 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.71 | -2.6 |
April | 21.75 | 4.03 |
May | 22.43 | 12.37 |
June | 23.63 | 16.19 |
July | 24.04 | 17.83 |
August | 24.06 | 17.50 |
September | 23.12 | 12.89 |
October | 21.78 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.45 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.06 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 17.82 | -13.0 |
February | 18.52 | -8.2 |
March | 19.82 | -2.6 |
April | 21.69 | 4.03 |
May | 23.43 | 12.37 |
June | 24.97 | 16.19 |
July | 25.53 | 17.83 |
August | 25.52 | 17.50 |
September | 24.56 | 12.89 |
October | 21.93 | 6.03 |
November | 19.35 | -4.5 |
December | 17.91 | -11.1 |
Annual Sum or Average | 21.77 | 4.02 |
Minimum of Months | 17.82 | -13.0 |
Maximum of Months | 25.53 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.70 | -2.6 |
April | 21.72 | 4.03 |
May | 22.33 | 12.37 |
June | 23.59 | 16.19 |
July | 23.98 | 17.83 |
August | 23.98 | 17.50 |
September | 23.02 | 12.89 |
October | 21.76 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.41 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 23.98 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.70 | -2.6 |
April | 21.71 | 4.03 |
May | 22.21 | 12.37 |
June | 23.56 | 16.19 |
July | 24.01 | 17.83 |
August | 24.01 | 17.50 |
September | 23.13 | 12.89 |
October | 21.76 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.41 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.01 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.70 | -2.6 |
April | 21.71 | 4.03 |
May | 22.20 | 12.37 |
June | 23.56 | 16.19 |
July | 24.01 | 17.83 |
August | 24.00 | 17.50 |
September | 23.12 | 12.89 |
October | 21.76 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.41 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.01 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.73 | -2.6 |
April | 21.83 | 4.03 |
May | 22.46 | 12.37 |
June | 23.70 | 16.19 |
July | 24.10 | 17.83 |
August | 24.17 | 17.50 |
September | 23.60 | 12.89 |
October | 21.96 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.53 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.17 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.73 | -2.6 |
April | 21.83 | 4.03 |
May | 22.49 | 12.37 |
June | 23.73 | 16.19 |
July | 24.13 | 17.83 |
August | 24.20 | 17.50 |
September | 23.63 | 12.89 |
October | 21.96 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.55 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.20 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.74 | -8.2 |
March | 21.85 | -2.6 |
April | 22.45 | 4.03 |
May | 23.98 | 12.37 |
June | 24.29 | 16.19 |
July | 24.37 | 17.83 |
August | 24.39 | 17.50 |
September | 24.05 | 12.89 |
October | 22.42 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.89 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.39 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.73 | -2.6 |
April | 21.97 | 4.03 |
May | 23.68 | 12.37 |
June | 24.26 | 16.19 |
July | 24.36 | 17.83 |
August | 24.37 | 17.50 |
September | 23.80 | 12.89 |
October | 22.01 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.76 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.37 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.73 | -8.2 |
March | 21.83 | -2.6 |
April | 22.44 | 4.03 |
May | 23.95 | 12.37 |
June | 24.29 | 16.19 |
July | 24.36 | 17.83 |
August | 24.38 | 17.50 |
September | 24.02 | 12.89 |
October | 22.40 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.88 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.38 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.72 | -2.6 |
April | 21.91 | 4.03 |
May | 23.58 | 12.37 |
June | 24.25 | 16.19 |
July | 24.33 | 17.83 |
August | 24.35 | 17.50 |
September | 23.71 | 12.89 |
October | 21.97 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.73 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.35 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.72 | -2.6 |
April | 21.90 | 4.03 |
May | 23.66 | 12.37 |
June | 24.31 | 16.19 |
July | 24.38 | 17.83 |
August | 24.38 | 17.50 |
September | 23.96 | 12.89 |
October | 22.08 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.77 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.38 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.72 | -2.6 |
April | 21.90 | 4.03 |
May | 23.65 | 12.37 |
June | 24.31 | 16.19 |
July | 24.38 | 17.83 |
August | 24.38 | 17.50 |
September | 23.95 | 12.89 |
October | 22.07 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.77 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.38 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.77 | -8.2 |
March | 21.88 | -2.6 |
April | 22.60 | 4.03 |
May | 24.10 | 12.37 |
June | 24.34 | 16.19 |
July | 24.39 | 17.83 |
August | 24.39 | 17.50 |
September | 24.22 | 12.89 |
October | 22.70 | 6.03 |
November | 21.72 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.97 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.39 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.77 | -8.2 |
March | 21.88 | -2.6 |
April | 22.61 | 4.03 |
May | 24.10 | 12.37 |
June | 24.34 | 16.19 |
July | 24.39 | 17.83 |
August | 24.39 | 17.50 |
September | 24.22 | 12.89 |
October | 22.70 | 6.03 |
November | 21.72 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.97 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.39 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.74 | -8.2 |
March | 21.86 | -2.6 |
April | 22.33 | 4.03 |
May | 23.49 | 12.37 |
June | 23.92 | 16.19 |
July | 24.13 | 17.83 |
August | 24.24 | 17.50 |
September | 23.36 | 12.89 |
October | 22.18 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.70 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.24 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.75 | -2.6 |
April | 22.01 | 4.03 |
May | 23.32 | 12.37 |
June | 23.87 | 16.19 |
July | 24.10 | 17.83 |
August | 24.16 | 17.50 |
September | 23.05 | 12.89 |
October | 21.90 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.59 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.16 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.73 | -8.2 |
March | 21.85 | -2.6 |
April | 22.32 | 4.03 |
May | 23.48 | 12.37 |
June | 23.93 | 16.19 |
July | 24.11 | 17.83 |
August | 24.22 | 17.50 |
September | 23.34 | 12.89 |
October | 22.17 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.70 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.22 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.73 | -2.6 |
April | 21.94 | 4.03 |
May | 23.24 | 12.37 |
June | 23.84 | 16.19 |
July | 24.03 | 17.83 |
August | 24.10 | 17.50 |
September | 22.98 | 12.89 |
October | 21.86 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.55 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.10 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.74 | -2.6 |
April | 21.93 | 4.03 |
May | 23.29 | 12.37 |
June | 23.91 | 16.19 |
July | 24.12 | 17.83 |
August | 24.19 | 17.50 |
September | 23.07 | 12.89 |
October | 21.88 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.58 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.19 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.70 | -8.2 |
March | 21.73 | -2.6 |
April | 21.92 | 4.03 |
May | 23.29 | 12.37 |
June | 23.91 | 16.19 |
July | 24.11 | 17.83 |
August | 24.18 | 17.50 |
September | 23.07 | 12.89 |
October | 21.88 | 6.03 |
November | 21.70 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.58 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.18 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.75 | -8.2 |
March | 21.88 | -2.6 |
April | 22.37 | 4.03 |
May | 23.58 | 12.37 |
June | 24.02 | 16.19 |
July | 24.20 | 17.83 |
August | 24.30 | 17.50 |
September | 23.53 | 12.89 |
October | 22.29 | 6.03 |
November | 21.71 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.76 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.30 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -13.0 |
February | 21.75 | -8.2 |
March | 21.88 | -2.6 |
April | 22.37 | 4.03 |
May | 23.58 | 12.37 |
June | 24.02 | 16.19 |
July | 24.20 | 17.83 |
August | 24.30 | 17.50 |
September | 23.53 | 12.89 |
October | 22.29 | 6.03 |
November | 21.71 | -4.5 |
December | 21.70 | -11.1 |
Annual Sum or Average | 22.76 | 4.02 |
Minimum of Months | 21.70 | -13.0 |
Maximum of Months | 24.30 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.81 | -13.0 |
February | 20.49 | -8.2 |
March | 21.26 | -2.6 |
April | 22.64 | 4.03 |
May | 24.82 | 12.37 |
June | 25.69 | 16.19 |
July | 26.02 | 17.83 |
August | 26.02 | 17.50 |
September | 24.54 | 12.89 |
October | 22.33 | 6.03 |
November | 20.74 | -4.5 |
December | 19.92 | -11.1 |
Annual Sum or Average | 22.87 | 4.02 |
Minimum of Months | 19.81 | -13.0 |
Maximum of Months | 26.02 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 15.86 | -13.0 |
February | 16.91 | -8.2 |
March | 18.08 | -2.6 |
April | 19.70 | 4.03 |
May | 21.88 | 12.37 |
June | 24.02 | 16.19 |
July | 24.81 | 17.83 |
August | 24.70 | 17.50 |
September | 23.32 | 12.89 |
October | 20.24 | 6.03 |
November | 17.74 | -4.5 |
December | 16.23 | -11.1 |
Annual Sum or Average | 20.31 | 4.02 |
Minimum of Months | 15.86 | -13.0 |
Maximum of Months | 24.81 | 17.83 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2015-09-09 18:47:40
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.00 | -13.0 |
February | 22.47 | -8.2 |
March | 22.88 | -2.6 |
April | 23.85 | 4.03 |
May | 25.80 | 12.37 |
June | 26.43 | 16.19 |
July | 26.58 | 17.83 |
August | 26.54 | 17.50 |
September | 25.92 | 12.89 |
October | 23.81 | 6.03 |
November | 22.54 | -4.5 |
December | 22.05 | -11.1 |
Annual Sum or Average | 24.25 | 4.02 |
Minimum of Months | 22.00 | -13.0 |
Maximum of Months | 26.58 | 17.83 |
Report: PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2015-09-09 18:47:40
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [Invalid/Undefined] | HEATREJECTION:ELECTRICITY [Invalid/Undefined] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined] | |
January | 0.118209E+12 | 73320.591 | 31-JAN-18:45 | 4979.953 | 26630.920 | 6602.291 | 0.000 | 0.000 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32554.426 | 0.000 | 0.000 | 0.000 |
February | 0.107138E+12 | 73332.079 | 07-FEB-18:45 | 4979.953 | 26630.920 | 6602.291 | 0.000 | 0.000 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32565.913 | 0.000 | 0.000 | 0.000 |
March | 0.118149E+12 | 71181.751 | 05-MAR-18:00 | 4979.953 | 26630.920 | 6602.291 | 0.000 | 0.000 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 30415.585 | 0.000 | 0.000 | 0.000 |
April | 0.113163E+12 | 70533.799 | 09-APR-17:00 | 4979.953 | 26630.920 | 6602.291 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32320.634 | 0.000 | 0.000 | 0.000 |
May | 0.119939E+12 | 77218.044 | 18-MAY-17:30 | 4979.953 | 26630.920 | 6602.291 | 0.000 | 12536.229 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 26468.649 | 0.000 | 0.000 | 0.000 |
June | 0.120773E+12 | 85847.164 | 28-JUN-17:00 | 4979.953 | 26630.920 | 6602.291 | 0.000 | 17033.201 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 30600.798 | 0.000 | 0.000 | 0.000 |
July | 0.126006E+12 | 84777.612 | 16-JUL-17:45 | 4979.953 | 26630.920 | 6602.291 | 0.000 | 21929.750 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 24634.697 | 0.000 | 0.000 | 0.000 |
August | 0.123113E+12 | 77140.190 | 25-AUG-17:45 | 4979.953 | 26630.920 | 6602.291 | 0.000 | 13514.885 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 25412.139 | 0.000 | 0.000 | 0.000 |
September | 0.111804E+12 | 73233.951 | 17-SEP-17:15 | 4979.953 | 26630.920 | 6602.291 | 0.000 | 11521.377 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23499.409 | 0.000 | 0.000 | 0.000 |
October | 0.113229E+12 | 68287.453 | 24-OCT-17:15 | 4979.953 | 26630.920 | 6602.291 | 0.000 | 0.000 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 27521.288 | 0.000 | 0.000 | 0.000 |
November | 0.111023E+12 | 73011.081 | 30-NOV-18:45 | 4979.953 | 26630.920 | 6602.291 | 0.000 | 0.000 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32244.916 | 0.000 | 0.000 | 0.000 |
December | 0.116726E+12 | 73200.118 | 23-DEC-18:00 | 4979.953 | 26630.920 | 6602.291 | 0.000 | 0.000 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32433.953 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.139927E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||
Minimum of Months | 0.107138E+12 | 68287.453 | 4979.953 | 26630.920 | 6602.291 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23499.409 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.126006E+12 | 85847.164 | 4979.953 | 26630.920 | 6602.291 | 0.000 | 21929.750 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32565.913 | 0.000 | 0.000 | 0.000 |
Report: PEAK GAS DEMAND
For: Meter
Timestamp: 2015-09-09 18:47:40
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC {AT MAX/MIN} [W] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT [Invalid/Undefined] | WATERSYSTEMS:GAS [Invalid/Undefined] | WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.225122E+12 | 175984.542 | 11-JAN-11:00 | 175984.542 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 175984.542 |
February | 0.150097E+12 | 138890.337 | 05-FEB-05:00 | 138890.337 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 138890.337 |
March | 0.114995E+12 | 111928.737 | 23-MAR-04:00 | 111928.737 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 111928.737 |
April | 0.392948E+11 | 49655.696 | 10-APR-02:00 | 49655.696 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 49655.696 |
May | 0.616818E+10 | 24604.551 | 01-MAY-03:00 | 24604.551 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 24604.551 |
June | 0.505827E+09 | 9135.960 | 02-JUN-00:00 | 9135.960 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 9135.960 |
July | 0.100413E+09 | 3453.565 | 02-JUL-03:45 | 3453.565 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 3453.565 |
August | 0.116662E+08 | 1149.865 | 18-AUG-04:00 | 1149.865 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 1149.865 |
September | 0.184266E+10 | 13288.189 | 29-SEP-02:00 | 13288.189 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 13288.189 |
October | 0.428795E+11 | 68972.530 | 26-OCT-00:00 | 68972.530 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 68972.530 |
November | 0.130752E+12 | 133382.610 | 28-NOV-07:15 | 133382.610 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 133382.610 |
December | 0.209565E+12 | 177327.734 | 19-DEC-02:00 | 177327.734 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 177327.734 |
Annual Sum or Average | 0.921333E+12 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | ||||
Minimum of Months | 0.116662E+08 | 1149.865 | 1149.865 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 1149.865 | |
Maximum of Months | 0.225122E+12 | 177327.734 | 177327.734 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 177327.734 |