Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:47
Tabular Output Report in Format: HTML
Building: Mid-Rise Apartment
Environment: Helena Regional Airport MT USA TMY3 WMO#=727720
Simulation Timestamp: 2015-09-09 18:47:55
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:55
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1859.47 | 593.20 | 658.46 |
Net Site Energy | 1859.47 | 593.20 | 658.46 |
Total Source Energy | 5017.04 | 1600.53 | 1776.59 |
Net Source Energy | 5017.04 | 1600.53 | 1776.59 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 3134.61 |
Net Conditioned Building Area | 2823.98 |
Unconditioned Building Area | 310.64 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 418.58 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 73.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 118.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 40.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 517.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 256.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 434.73 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1440.89 | 418.58 | 0.00 | 0.00 | 0.00 | 1874.72 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 418.58 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 73.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 96.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 22.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 40.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 517.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 256.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 434.73 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 56.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 270.80 | 148.22 | 0.00 | 0.00 | 0.00 | 0.66 |
Other | 183.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 510.23 | 148.22 | 0.00 | 0.00 | 0.00 | 0.66 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 50.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 243.96 | 133.53 | 0.00 | 0.00 | 0.00 | 0.60 |
Other | 165.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 459.67 | 133.53 | 0.00 | 0.00 | 0.00 | 0.60 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 1440.89 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 1440.89 | 100.00 |
Total On-Site and Utility Electric Sources | 1440.89 | 100.00 |
Total Electricity End Uses | 1440.89 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 1874.72 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 1874.72 | 100.00 |
Total Water End Uses | 1874.72 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 40.75 |
Time Setpoint Not Met During Occupied Cooling | 0.50 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 3032.50 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PEAK ELECTRICAL DEMAND
| Meter |PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:55
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:47 |
RunPeriod | Helena Regional Airport MT USA TMY3 WMO#=727720 |
Weather File | Helena Regional Airport MT USA TMY3 WMO#=727720 |
Latitude [deg] | 46.60 |
Longitude [deg] | -112.0 |
Elevation [m] | 1167.00 |
Time Zone | -7.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
Window Opening Area [m2] | 306.92 | 112.97 | 37.16 | 112.97 | 43.82 |
Window-Wall Ratio [%] | 19.90 | 20.00 | 18.02 | 20.00 | 21.25 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 26.1977 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 1.11 | 5.9540 | 0.0000 | |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 3.32 | 5.9540 | 208.8202 | |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 1.11 | 5.9540 | 0.0000 | |
Total | 3134.61 | 9553.84 | 1542.04 | 306.92 | 4.5346 | 39.93 | 11.1825 | |||
Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 300.26 | 4.3785 | 35.97 | 6.6700 | |||
Unconditioned Total | 310.64 | 946.78 | 40.87 | 6.66 | 5.9540 | 52.2051 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:55
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 19-JUL-17:15 | 25-DEC-08:00 | - | - | - | 01-JAN-07:15 |
Heating | 0.00 | 104817.13 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 18090.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 4979.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 26630.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 8148.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 24991.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 82841.81 | 104817.13 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 104817.13 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 18090.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 4056.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 923.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 26630.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 8148.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 24991.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:55
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 453.74 | 0.00 | 0.00 | 0.00 |
Cooling | 231.28 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 375.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 126.83 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1639.40 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 813.83 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 1376.80 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 4563.30 | 453.74 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 160.67 | 0.00 | 0.00 | 0.00 |
Cooling | 81.90 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 132.85 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.91 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 580.53 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 288.18 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 487.54 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1615.91 | 160.67 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 160.67 | 0.00 | 0.00 | 0.00 |
Cooling | 81.90 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 132.85 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.91 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 580.53 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 288.18 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 487.54 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1615.91 | 160.67 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:55
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | -26.30 | 0.00 | -26.30 | Wetbulb [C] | 1.60 | 300.00 |
HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 33.70 | 16.10 | 16.40 | Wetbulb [C] | 4.90 | 290.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:55
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 46.45 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 70.60 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 70.60 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 46.45 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 46.45 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 70.60 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 70.60 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 46.45 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 70.60 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 70.60 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 70.60 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 70.60 | 180.00 | 90.00 | S |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.30 | 0.269 | 0.283 | 77.66 | 180.00 | 0.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 90.00 | 180.00 | |
M WWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 10.22 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.324 | 0.340 | 10.22 | 90.00 | 90.00 | E |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW1 S SWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW1 W SWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW1 N NWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW1 W NWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 S SEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW1 E SEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW1 N NEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW1 E NEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW1 N N1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW1 N N2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW1 S S1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW1 S S2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW1 W SWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.653 | 0.426 | 0.308 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW1 S SWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW1 N NWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW1 W NWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.653 | 0.426 | 0.308 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW1 E SEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.653 | 0.426 | 0.308 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 S SEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW1 N NEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW1 E NEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.653 | 0.426 | 0.308 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW1 N N1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW1 N N2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW1 S S1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW1 S S2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW1 W SWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW1 S SWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW1 N NWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW1 W NWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW1 E SEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 S SEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW1 N NEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW1 E NEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW1 N N1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW1 N N2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW1 S S1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW1 S S2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW14 | WINDOW_U_0.52_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | T EWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_0.52_SHGC_0.40 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 2.653 | 0.426 | 0.308 | No | G EWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_0.52_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 2.653 | 0.426 | 0.308 | No | M EWALL C | 270.00 | 90.00 | W | ||
Total or Average | 306.92 | 2.653 | 0.426 | 0.308 | ||||||||||||
North Total or Average | 112.97 | 2.653 | 0.426 | 0.308 | ||||||||||||
Non-North Total or Average | 193.95 | 2.653 | 0.426 | 0.308 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:55
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:55
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
LIGHTING_HARDWIRED_GSW | G SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GNW | G NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_OFFICE | OFFICE | 13.0989 | 88.25 | 1155.96 | GeneralLights | LTG_OFF_SCH | 62.17 | 168.00 | 60.95 | 0.0000 | Y | 13.23 |
LIGHTING_HARDWIRED_GNE | G NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MSW | M SW APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MNW | M NW APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MSE | M SE APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MNE | M NE APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TSW | T SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TNW | T NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TSE | T SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TNE | T NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GC | G CORRIDOR | 5.9540 | 77.66 | 462.39 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 14.58 |
LIGHTING_HARDWIRED_MC | M CORRIDOR | 5.9540 | 155.32 | 924.77 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 14.58 |
LIGHTING_HARDWIRED_TC | T CORRIDOR | 5.9540 | 77.66 | 462.39 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 14.58 |
LIGHTING_PLUGIN_GSW | G SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_GNW | G NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_OFFICE | OFFICE | 13.0989 | 88.25 | 1155.96 | GeneralLights-plugin | LTG_OFF_SCH | 62.17 | 168.00 | 60.95 | 0.0000 | Y | 13.23 |
LIGHTING_PLUGIN_GNE | G NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MSW | M SW APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MNW | M NW APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MSE | M SE APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MNE | M NE APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TSW | T SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TNW | T NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TSE | T SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TNE | T NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
Interior Lighting Total | 2.3855 | 5958.59 | 14214.30 | 95.19 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 2553.00 | AstronomicalClock | - | 83.56 | 83.56 | 40.05 | |
Exterior Lighting Total | 2553.00 | 40.05 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:55
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3223.35 | 2574.34 | 649.00 | 0.80 | 3.91 | |||
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2919.64 | 2331.79 | 587.85 | 0.80 | 3.91 | |||
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8470.75 | 6765.21 | 1705.54 | 0.80 | 3.91 | |||
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2040.74 | 1629.85 | 410.89 | 0.80 | 3.91 | |||
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1571.78 | 1255.31 | 316.47 | 0.80 | 3.91 | |||
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1549.85 | 1237.80 | 312.05 | 0.80 | 3.91 | |||
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2123.47 | 1695.92 | 427.55 | 0.80 | 3.91 | |||
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2182.55 | 1743.11 | 439.45 | 0.80 | 3.91 | |||
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9060.84 | 7236.49 | 1824.35 | 0.80 | 3.91 | |||
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8139.50 | 6500.66 | 1638.85 | 0.80 | 3.91 | |||
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8358.03 | 6675.18 | 1682.84 | 0.80 | 3.91 | |||
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6298.75 | 5030.53 | 1268.22 | 0.80 | 3.91 | |||
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4729.52 | 3777.25 | 952.26 | 0.80 | 3.91 | |||
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4692.38 | 3747.60 | 944.79 | 0.80 | 3.91 | |||
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6277.49 | 5013.55 | 1263.94 | 0.80 | 3.91 | |||
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6301.33 | 5032.59 | 1268.74 | 0.80 | 3.91 | |||
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6197.92 | 4950.00 | 1247.92 | 0.80 | 3.91 | |||
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5450.59 | 4353.14 | 1097.45 | 0.80 | 3.91 | |||
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5817.90 | 4646.50 | 1171.40 | 0.80 | 3.91 | |||
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4427.21 | 3535.82 | 891.40 | 0.80 | 3.91 | |||
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3425.15 | 2735.52 | 689.64 | 0.80 | 3.91 | |||
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3425.20 | 2735.56 | 689.65 | 0.80 | 3.91 | |||
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4748.65 | 3792.53 | 956.12 | 0.80 | 3.91 | |||
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4764.57 | 3805.25 | 959.32 | 0.80 | 3.91 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3070.7 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2781.4 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8069.7 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1944.1 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1497.4 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 1476.5 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2022.9 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2079.2 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8631.9 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7754.2 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7962.3 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6000.5 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4505.6 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4470.2 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5980.3 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6003.0 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5904.5 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5192.5 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5542.5 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4217.6 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3263.0 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3263.0 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4523.8 | 3.13 | 10.67 | 11.09 | 10.38 |
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4539.0 | 3.13 | 10.67 | 11.09 | 10.38 |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
SPLIT GSW HEATING COIL | Coil:Heating:Gas | 3677.46 | 0.80 | |
SPLIT GNW HEATING COIL | Coil:Heating:Gas | 3646.64 | 0.80 | |
SPLIT OFFICE HEATING COIL | Coil:Heating:Gas | 6389.14 | 0.80 | |
SPLIT GNE HEATING COIL | Coil:Heating:Gas | 3637.61 | 0.80 | |
SPLIT GN1 HEATING COIL | Coil:Heating:Gas | 2830.30 | 0.80 | |
SPLIT GN2 HEATING COIL | Coil:Heating:Gas | 2830.09 | 0.80 | |
SPLIT GS1 HEATING COIL | Coil:Heating:Gas | 2816.84 | 0.80 | |
SPLIT GS2 HEATING COIL | Coil:Heating:Gas | 2950.70 | 0.80 | |
SPLIT MSW HEATING COIL | Coil:Heating:Gas | 6845.21 | 0.80 | |
SPLIT MNW HEATING COIL | Coil:Heating:Gas | 6885.27 | 0.80 | |
SPLIT MSE HEATING COIL | Coil:Heating:Gas | 6821.26 | 0.80 | |
SPLIT MNE HEATING COIL | Coil:Heating:Gas | 6861.30 | 0.80 | |
SPLIT MN1 HEATING COIL | Coil:Heating:Gas | 4888.65 | 0.80 | |
SPLIT MN2 HEATING COIL | Coil:Heating:Gas | 4888.07 | 0.80 | |
SPLIT MS1 HEATING COIL | Coil:Heating:Gas | 4851.33 | 0.80 | |
SPLIT MS2 HEATING COIL | Coil:Heating:Gas | 4850.75 | 0.80 | |
SPLIT TSW HEATING COIL | Coil:Heating:Gas | 5194.76 | 0.80 | |
SPLIT TNW HEATING COIL | Coil:Heating:Gas | 5218.05 | 0.80 | |
SPLIT TSE HEATING COIL | Coil:Heating:Gas | 5181.93 | 0.80 | |
SPLIT TNE HEATING COIL | Coil:Heating:Gas | 5205.22 | 0.80 | |
SPLIT TN1 HEATING COIL | Coil:Heating:Gas | 4176.00 | 0.80 | |
SPLIT TN2 HEATING COIL | Coil:Heating:Gas | 4175.67 | 0.80 | |
SPLIT TS1 HEATING COIL | Coil:Heating:Gas | 4151.02 | 0.80 | |
SPLIT TS2 HEATING COIL | Coil:Heating:Gas | 4150.69 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 226.04 | 1160.84 | 1.00 | General |
SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.18 | 204.74 | 1160.84 | 1.00 | General |
SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.51 | 594.02 | 1160.84 | 1.00 | General |
SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.12 | 143.11 | 1160.84 | 1.00 | General |
SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.09 | 110.22 | 1160.84 | 1.00 | General |
SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.09 | 108.69 | 1160.84 | 1.00 | General |
SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.13 | 148.91 | 1160.84 | 1.00 | General |
SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.13 | 153.05 | 1160.84 | 1.00 | General |
SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.55 | 635.40 | 1160.84 | 1.00 | General |
SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.49 | 570.79 | 1160.84 | 1.00 | General |
SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.50 | 586.12 | 1160.84 | 1.00 | General |
SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.38 | 441.71 | 1160.84 | 1.00 | General |
SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.29 | 331.66 | 1160.84 | 1.00 | General |
SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.28 | 329.06 | 1160.84 | 1.00 | General |
SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.38 | 440.22 | 1160.84 | 1.00 | General |
SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.38 | 441.89 | 1160.84 | 1.00 | General |
SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.37 | 434.64 | 1160.84 | 1.00 | General |
SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 382.23 | 1160.84 | 1.00 | General |
SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.35 | 407.99 | 1160.84 | 1.00 | General |
SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 310.46 | 1160.84 | 1.00 | General |
SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 240.19 | 1160.84 | 1.00 | General |
SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.21 | 240.20 | 1160.84 | 1.00 | General |
SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.29 | 333.01 | 1160.84 | 1.00 | General |
SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.29 | 334.12 | 1160.84 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
G SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:55
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 1801.33 | 2161.60 | 0.162 | 0.195 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 29.84 | 0.00635 |
G NW APARTMENT | 1631.61 | 1957.94 | 0.147 | 0.176 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 29.23 | 0.00635 |
OFFICE | 4628.63 | 5554.36 | 0.426 | 0.512 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 | 24.84 | 0.00635 |
G NE APARTMENT | 1140.46 | 1368.55 | 0.103 | 0.123 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 29.39 | 0.00635 |
G N1 APARTMENT | 878.37 | 1054.04 | 0.079 | 0.095 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
G N2 APARTMENT | 866.11 | 1039.33 | 0.078 | 0.094 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
G S1 APARTMENT | 1186.68 | 1424.01 | 0.107 | 0.128 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
G S2 APARTMENT | 1219.70 | 1463.64 | 0.110 | 0.132 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 33.70 | 0.00635 |
M SW APARTMENT | 5063.60 | 6076.32 | 0.456 | 0.547 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 30.24 | 0.00635 |
M NW APARTMENT | 4548.71 | 5458.45 | 0.410 | 0.492 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 18:15:00 | 29.23 | 0.00635 |
M SE APARTMENT | 4670.91 | 5605.10 | 0.421 | 0.505 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 33.70 | 0.00635 |
M NE APARTMENT | 3520.08 | 4224.10 | 0.317 | 0.381 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 30.00 | 0.00635 |
M N1 APARTMENT | 2643.02 | 3171.63 | 0.238 | 0.286 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
M N2 APARTMENT | 2622.27 | 3146.73 | 0.236 | 0.283 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 19:00:00 | 27.42 | 0.00635 |
M S1 APARTMENT | 3508.14 | 4209.77 | 0.316 | 0.379 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
M S2 APARTMENT | 3521.46 | 4225.76 | 0.317 | 0.381 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
T SW APARTMENT | 3463.79 | 4156.55 | 0.312 | 0.374 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:45:00 | 32.98 | 0.00635 |
T NW APARTMENT | 3046.06 | 3655.27 | 0.274 | 0.329 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 30.24 | 0.00635 |
T SE APARTMENT | 3251.41 | 3901.69 | 0.293 | 0.351 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
T NE APARTMENT | 2474.21 | 2969.05 | 0.223 | 0.267 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 33.70 | 0.00635 |
T N1 APARTMENT | 1914.15 | 2296.98 | 0.172 | 0.207 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 | 33.22 | 0.00635 |
T N2 APARTMENT | 1914.18 | 2297.01 | 0.172 | 0.207 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 15:15:00 | 33.46 | 0.00635 |
T S1 APARTMENT | 2653.78 | 3184.54 | 0.239 | 0.287 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 33.70 | 0.00635 |
T S2 APARTMENT | 2662.68 | 3195.22 | 0.240 | 0.288 | HELENA REGIONAL AIRPORT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:15:00 | 33.70 | 0.00635 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 1961.42 | 2353.70 | 0.065 | 0.078 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -26.30 | 0.00039 |
G NW APARTMENT | 1975.72 | 2370.87 | 0.065 | 0.078 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -26.30 | 0.00039 |
OFFICE | 3818.92 | 4582.71 | 0.122 | 0.147 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -26.30 | 0.00039 |
G NE APARTMENT | 1968.09 | 2361.71 | 0.065 | 0.078 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -26.30 | 0.00039 |
G N1 APARTMENT | 1285.38 | 1542.46 | 0.043 | 0.051 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -26.30 | 0.00039 |
G N2 APARTMENT | 1285.20 | 1542.25 | 0.043 | 0.051 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -26.30 | 0.00039 |
G S1 APARTMENT | 1274.00 | 1528.80 | 0.042 | 0.051 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -26.30 | 0.00039 |
G S2 APARTMENT | 1387.19 | 1664.63 | 0.046 | 0.055 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -26.30 | 0.00039 |
M SW APARTMENT | 3572.61 | 4287.13 | 0.118 | 0.142 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -26.30 | 0.00039 |
M NW APARTMENT | 3606.48 | 4327.77 | 0.119 | 0.143 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -26.30 | 0.00039 |
M SE APARTMENT | 3552.35 | 4262.82 | 0.118 | 0.141 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -26.30 | 0.00039 |
M NE APARTMENT | 3586.21 | 4303.45 | 0.119 | 0.142 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -26.30 | 0.00039 |
M N1 APARTMENT | 1917.99 | 2301.59 | 0.063 | 0.076 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -26.30 | 0.00039 |
M N2 APARTMENT | 1917.50 | 2301.00 | 0.063 | 0.076 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -26.30 | 0.00039 |
M S1 APARTMENT | 1886.43 | 2263.72 | 0.062 | 0.075 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -26.30 | 0.00039 |
M S2 APARTMENT | 1885.94 | 2263.13 | 0.062 | 0.075 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -26.30 | 0.00039 |
T SW APARTMENT | 3284.95 | 3941.94 | 0.109 | 0.130 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -26.30 | 0.00039 |
T NW APARTMENT | 3304.64 | 3965.57 | 0.109 | 0.131 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -26.30 | 0.00039 |
T SE APARTMENT | 3274.10 | 3928.92 | 0.108 | 0.130 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -26.30 | 0.00039 |
T NE APARTMENT | 3293.79 | 3952.54 | 0.109 | 0.131 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -26.30 | 0.00039 |
T N1 APARTMENT | 2423.40 | 2908.08 | 0.080 | 0.096 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -26.30 | 0.00039 |
T N2 APARTMENT | 2423.12 | 2907.74 | 0.080 | 0.096 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -26.30 | 0.00039 |
T S1 APARTMENT | 2402.28 | 2882.73 | 0.080 | 0.095 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -26.30 | 0.00039 |
T S2 APARTMENT | 2402.00 | 2882.40 | 0.080 | 0.095 | HELENA REGIONAL AIRPORT ANN HTG 99.6% CONDNS DB | 12/21 04:00:00 | -26.30 | 0.00039 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
SPLIT GSW | 0.19 | 0.19 | 0.08 | 0.08 |
SPLIT GNW | 0.18 | 0.18 | 0.08 | 0.08 |
SPLIT OFFICE | 0.51 | 0.51 | 0.15 | 0.15 |
SPLIT GNE | 0.12 | 0.12 | 0.08 | 0.08 |
SPLIT GN1 | 0.09 | 0.09 | 0.05 | 0.05 |
SPLIT GN2 | 0.09 | 0.09 | 0.05 | 0.05 |
SPLIT GS1 | 0.13 | 0.13 | 0.05 | 0.05 |
SPLIT GS2 | 0.13 | 0.13 | 0.06 | 0.06 |
SPLIT MSW | 0.55 | 0.55 | 0.14 | 0.14 |
SPLIT MNW | 0.49 | 0.49 | 0.14 | 0.14 |
SPLIT MSE | 0.50 | 0.50 | 0.14 | 0.14 |
SPLIT MNE | 0.38 | 0.38 | 0.14 | 0.14 |
SPLIT MN1 | 0.29 | 0.29 | 0.08 | 0.08 |
SPLIT MN2 | 0.28 | 0.28 | 0.08 | 0.08 |
SPLIT MS1 | 0.38 | 0.38 | 0.07 | 0.07 |
SPLIT MS2 | 0.38 | 0.38 | 0.07 | 0.07 |
SPLIT TSW | 0.37 | 0.37 | 0.13 | 0.13 |
SPLIT TNW | 0.33 | 0.33 | 0.13 | 0.13 |
SPLIT TSE | 0.35 | 0.35 | 0.13 | 0.13 |
SPLIT TNE | 0.27 | 0.27 | 0.13 | 0.13 |
SPLIT TN1 | 0.21 | 0.21 | 0.10 | 0.10 |
SPLIT TN2 | 0.21 | 0.21 | 0.10 | 0.10 |
SPLIT TS1 | 0.29 | 0.29 | 0.10 | 0.10 |
SPLIT TS2 | 0.29 | 0.29 | 0.10 | 0.10 |
Report: System Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:55
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 2260.00 | 6520.50 | 1526.25 |
G NW APARTMENT | 2780.25 | 6832.25 | 2368.00 |
OFFICE | 393.50 | 1617.75 | 146.75 |
G NE APARTMENT | 2871.50 | 6879.00 | 2378.00 |
G N1 APARTMENT | 1830.25 | 7029.25 | 1699.25 |
G N2 APARTMENT | 1833.00 | 7027.00 | 1701.50 |
G S1 APARTMENT | 1310.00 | 6582.00 | 847.25 |
G S2 APARTMENT | 1497.00 | 6512.00 | 971.00 |
M SW APARTMENT | 1949.75 | 5008.75 | 282.25 |
M NW APARTMENT | 2168.25 | 5641.50 | 863.00 |
M SE APARTMENT | 2023.75 | 5007.25 | 287.25 |
M NE APARTMENT | 2228.00 | 5671.25 | 869.00 |
M N1 APARTMENT | 1297.75 | 5614.75 | 296.50 |
M N2 APARTMENT | 1300.75 | 5621.00 | 296.25 |
M S1 APARTMENT | 1502.75 | 4733.50 | 48.75 |
M S2 APARTMENT | 1504.75 | 4731.75 | 48.75 |
T SW APARTMENT | 3580.50 | 5767.00 | 2052.25 |
T NW APARTMENT | 4072.25 | 6264.75 | 2820.25 |
T SE APARTMENT | 3630.75 | 5739.25 | 2053.75 |
T NE APARTMENT | 4169.50 | 6293.25 | 2840.25 |
T N1 APARTMENT | 3508.50 | 6319.50 | 2439.25 |
T N2 APARTMENT | 3512.25 | 6317.25 | 2439.75 |
T S1 APARTMENT | 2902.00 | 5708.50 | 1528.75 |
T S2 APARTMENT | 2912.25 | 5695.75 | 1533.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 5180.75 | 7115.25 | 3032.50 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 3.50 | 0.00 | 3.50 | 0.00 |
G NW APARTMENT | 4.50 | 0.50 | 4.50 | 0.50 |
OFFICE | 7.25 | 3.00 | 0.00 | 0.00 |
G NE APARTMENT | 4.25 | 0.00 | 4.25 | 0.00 |
G N1 APARTMENT | 2.50 | 0.00 | 2.50 | 0.00 |
G N2 APARTMENT | 4.00 | 0.00 | 4.00 | 0.00 |
G S1 APARTMENT | 3.50 | 0.00 | 3.50 | 0.00 |
G S2 APARTMENT | 4.00 | 0.00 | 4.00 | 0.00 |
M SW APARTMENT | 0.75 | 0.00 | 0.75 | 0.00 |
M NW APARTMENT | 1.75 | 0.00 | 1.75 | 0.00 |
M SE APARTMENT | 1.00 | 0.00 | 1.00 | 0.00 |
M NE APARTMENT | 1.75 | 0.00 | 1.75 | 0.00 |
M N1 APARTMENT | 1.50 | 0.00 | 1.50 | 0.00 |
M N2 APARTMENT | 1.25 | 0.00 | 1.25 | 0.00 |
M S1 APARTMENT | 0.25 | 0.00 | 0.25 | 0.00 |
M S2 APARTMENT | 0.50 | 0.00 | 0.50 | 0.00 |
T SW APARTMENT | 0.50 | 0.00 | 0.50 | 0.00 |
T NW APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T SE APARTMENT | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 0.50 | 0.00 | 0.50 | 0.00 |
T N1 APARTMENT | 1.25 | 0.00 | 1.25 | 0.00 |
T N2 APARTMENT | 3.75 | 0.00 | 3.75 | 0.00 |
T S1 APARTMENT | 1.00 | 0.00 | 1.00 | 0.00 |
T S2 APARTMENT | 1.25 | 0.00 | 1.25 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 48.00 | 3.50 | 40.75 | 0.50 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:55
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.365 | 0.148 | 0.000 | 0.057 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.148 | 0.000 | 0.056 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.519 | 0.166 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.148 | 0.000 | 0.056 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.089 | 0.000 | 0.055 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.089 | 0.000 | 0.055 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.089 | 0.000 | 0.056 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.089 | 0.000 | 0.056 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.213 | 0.000 | 0.068 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.212 | 0.000 | 0.068 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.213 | 0.000 | 0.068 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.212 | 0.000 | 0.068 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.128 | 0.000 | 0.068 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.128 | 0.000 | 0.068 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.128 | 0.000 | 0.068 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.128 | 0.000 | 0.068 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.281 | 0.000 | 0.079 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.281 | 0.000 | 0.080 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.281 | 0.000 | 0.079 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.281 | 0.000 | 0.080 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.169 | 0.000 | 0.080 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.169 | 0.000 | 0.080 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.170 | 0.000 | 0.079 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.170 | 0.000 | 0.079 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.355 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.503 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 1.370 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 1.370 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 1.370 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 1.370 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.370 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.370 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.370 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.370 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.342 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:55
Surfaces by ClassTotal | Outdoors | |
Wall | 126 | 42 |
Floor | 27 | 9 |
Roof | 27 | 9 |
Internal Mass | 24 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 39 | 39 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 24 |
Conditioned Zones | 24 |
Unconditioned Zones | 3 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 1385 |
Defaulted Fields | 439 |
Fields with Defaults | 3704 |
Autosized Fields | 336 |
Autosizable Fields | 454 |
Autocalculated Fields | 247 |
Autocalculatable Fields | 424 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2015-09-09 18:47:55
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 1440.89 | 21261.09 | 01-JAN-03:15 | 82841.81 | 19-JUL-17:15 |
Electricity:Building | 636.11 | 10559.61 | 01-JAN-03:15 | 31610.87 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity | 118.46 | 2466.75 | 01-JAN-00:15 | 5482.59 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 96.36 | 2205.67 | 01-JAN-00:15 | 4426.44 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 35.93 | 610.39 | 01-JAN-00:15 | 2669.36 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 26.45 | 416.15 | 01-JAN-00:15 | 2080.74 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M SW APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:T SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 144.16 | 1427.03 | 01-JAN-00:15 | 8651.76 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 14.58 | 462.39 | 01-JAN-00:15 | 462.39 | 01-JAN-00:15 |
Electricity:Zone:M CORRIDOR | 29.16 | 924.77 | 01-JAN-00:15 | 924.77 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 29.16 | 924.77 | 01-JAN-00:15 | 924.77 | 01-JAN-00:15 |
Electricity:Zone:T CORRIDOR | 14.58 | 462.39 | 01-JAN-00:15 | 462.39 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 14.58 | 462.39 | 01-JAN-00:15 | 462.39 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 22.11 | 261.08 | 01-JAN-00:15 | 1411.40 | 02-JAN-16:15 |
InteriorEquipment:Electricity | 517.65 | 8092.87 | 01-JAN-03:15 | 26730.99 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 517.65 | 8092.87 | 01-JAN-03:15 | 26730.99 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 9.48 | 194.25 | 01-JAN-00:15 | 588.62 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G CORRIDOR | 129.57 | 964.65 | 01-JAN-00:15 | 8189.37 | 01-JAN-07:15 |
Electricity:Plant | 434.73 | 0.00 | 01-JAN-00:15 | 32854.10 | 23-FEB-07:15 |
WaterSystems:Electricity | 434.73 | 0.00 | 01-JAN-00:15 | 32854.10 | 23-FEB-07:15 |
Water Heater:WaterSystems:Electricity | 434.73 | 0.00 | 01-JAN-00:15 | 32854.10 | 23-FEB-07:15 |
Fans:Electricity | 256.97 | 8148.48 | 04-JAN-18:15 | 8148.48 | 01-JAN-00:15 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 1440.89 | 21261.09 | 01-JAN-03:15 | 82841.81 | 19-JUL-17:15 |
ElectricityPurchased:Plant | 1440.89 | 21261.09 | 01-JAN-03:15 | 82841.81 | 19-JUL-17:15 |
Cogeneration:ElectricityPurchased | 1440.89 | 21261.09 | 01-JAN-03:15 | 82841.81 | 19-JUL-17:15 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 1440.89 | 21261.09 | 01-JAN-03:15 | 82841.81 | 19-JUL-17:15 |
ElectricityNet:Plant | 1440.89 | 21261.09 | 01-JAN-03:15 | 82841.81 | 19-JUL-17:15 |
Cogeneration:ElectricityNet | 1440.89 | 21261.09 | 01-JAN-03:15 | 82841.81 | 19-JUL-17:15 |
ExteriorLights:Electricity | 40.05 | 0.00 | 01-JAN-08:30 | 2553.00 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 40.05 | 0.00 | 01-JAN-08:30 | 2553.00 | 01-JAN-00:15 |
Electricity:HVAC | 330.00 | 8148.48 | 04-JAN-18:15 | 29748.41 | 10-AUG-15:30 |
General:Fans:Electricity | 256.97 | 8148.48 | 04-JAN-18:15 | 8148.48 | 01-JAN-00:15 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:Electricity | 73.03 | 0.00 | 01-JAN-00:15 | 21599.93 | 10-AUG-15:30 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 418.58 | 0.00 | 18-MAR-15:45 | 104817.13 | 25-DEC-09:00 |
Gas:HVAC | 418.58 | 0.00 | 18-MAR-15:45 | 104817.13 | 25-DEC-09:00 |
Heating:Gas | 418.58 | 0.00 | 18-MAR-15:45 | 104817.13 | 25-DEC-09:00 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 1113.50 | 1851.25 | 26-MAR-20:45 | 144564.99 | 10-AUG-15:30 |
EnergyTransfer:Building | 493.87 | 1581.68 | 11-MAY-16:15 | 64330.33 | 10-AUG-15:30 |
EnergyTransfer:Zone:G SW APARTMENT | 12.29 | 0.03 | 30-JUN-05:45 | 2029.72 | 10-AUG-16:15 |
Heating:EnergyTransfer | 180.79 | 0.00 | 19-MAR-11:30 | 59559.97 | 25-DEC-09:00 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 6.35 | 0.00 | 02-JAN-14:00 | 1977.40 | 25-DEC-09:00 |
Cooling:EnergyTransfer | 313.08 | 0.00 | 02-JAN-07:30 | 64330.33 | 10-AUG-15:30 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 5.94 | 0.00 | 01-JAN-00:15 | 2029.72 | 10-AUG-16:15 |
EnergyTransfer:Zone:G NW APARTMENT | 13.00 | 0.00 | 27-MAY-02:15 | 2070.83 | 25-DEC-09:00 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 9.18 | 0.00 | 11-FEB-16:30 | 2070.83 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 3.82 | 0.00 | 01-JAN-00:15 | 1720.95 | 21-JUL-17:30 |
EnergyTransfer:Zone:OFFICE | 21.43 | 0.01 | 08-NOV-00:45 | 4410.42 | 10-AUG-13:30 |
Heating:EnergyTransfer:Zone:OFFICE | 2.26 | 0.00 | 01-JAN-00:15 | 3462.16 | 27-DEC-07:15 |
Cooling:EnergyTransfer:Zone:OFFICE | 19.18 | 0.00 | 02-JAN-07:30 | 4410.42 | 10-AUG-13:30 |
EnergyTransfer:Zone:G NE APARTMENT | 13.25 | 0.02 | 01-NOV-19:15 | 2042.69 | 25-DEC-09:00 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 9.09 | 0.00 | 04-MAR-16:15 | 2042.69 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 4.16 | 0.00 | 01-JAN-00:15 | 1204.47 | 06-AUG-16:15 |
EnergyTransfer:Zone:G N1 APARTMENT | 8.42 | 0.04 | 10-MAY-09:15 | 1257.67 | 25-DEC-09:00 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 4.88 | 0.00 | 26-JAN-21:00 | 1257.67 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 3.54 | 0.00 | 01-JAN-00:15 | 894.07 | 21-JUL-18:00 |
EnergyTransfer:Zone:G N2 APARTMENT | 8.44 | 0.07 | 25-OCT-04:15 | 1257.08 | 25-DEC-09:00 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 4.88 | 0.00 | 26-JAN-21:00 | 1257.08 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 3.55 | 0.00 | 01-JAN-00:15 | 883.68 | 21-JUL-18:00 |
EnergyTransfer:Zone:G S1 APARTMENT | 8.61 | 0.00 | 02-JUN-15:45 | 1345.11 | 02-SEP-13:15 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 2.68 | 0.00 | 01-JAN-11:30 | 1164.19 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 5.93 | 0.00 | 01-JAN-00:15 | 1345.11 | 02-SEP-13:15 |
EnergyTransfer:Zone:G S2 APARTMENT | 9.13 | 0.03 | 01-DEC-10:30 | 1443.04 | 02-SEP-13:15 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 2.99 | 0.00 | 01-JAN-11:45 | 1271.60 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 6.14 | 0.00 | 01-JAN-00:15 | 1443.04 | 02-SEP-13:15 |
EnergyTransfer:Zone:M SW APARTMENT | 33.19 | 0.03 | 07-NOV-13:30 | 5597.48 | 10-AUG-16:15 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 5.70 | 0.00 | 01-JAN-11:30 | 3957.65 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 27.49 | 0.00 | 01-JAN-00:15 | 5597.48 | 10-AUG-16:15 |
EnergyTransfer:Zone:M NW APARTMENT | 29.20 | 0.11 | 14-APR-09:45 | 5012.73 | 30-JUN-18:00 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 11.38 | 0.00 | 04-JAN-22:00 | 4335.46 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 17.81 | 0.00 | 01-JAN-00:15 | 5012.73 | 30-JUN-18:00 |
EnergyTransfer:Zone:M SE APARTMENT | 34.22 | 0.40 | 08-DEC-11:00 | 5195.52 | 10-AUG-13:45 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 5.77 | 0.00 | 01-JAN-10:00 | 3885.77 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 28.46 | 0.00 | 01-JAN-00:15 | 5195.52 | 10-AUG-13:45 |
EnergyTransfer:Zone:M NE APARTMENT | 30.37 | 0.05 | 04-NOV-03:30 | 4266.10 | 25-DEC-09:00 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 11.42 | 0.00 | 04-JAN-22:00 | 4266.10 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 18.95 | 0.00 | 01-JAN-00:15 | 3702.11 | 18-JUN-17:00 |
EnergyTransfer:Zone:M N1 APARTMENT | 21.36 | 0.06 | 05-APR-13:45 | 2844.56 | 30-JUN-18:30 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 3.24 | 0.00 | 01-JAN-16:00 | 2220.04 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 18.12 | 0.00 | 01-JAN-00:15 | 2844.56 | 30-JUN-18:30 |
EnergyTransfer:Zone:M N2 APARTMENT | 21.38 | 0.06 | 02-APR-09:15 | 2814.66 | 30-JUN-18:30 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 3.25 | 0.00 | 01-JAN-16:00 | 2217.76 | 25-DEC-12:00 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 18.13 | 0.00 | 01-JAN-00:15 | 2814.66 | 30-JUN-18:30 |
EnergyTransfer:Zone:M S1 APARTMENT | 31.32 | 0.04 | 23-FEB-12:45 | 3949.37 | 13-SEP-15:15 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 1.00 | 0.00 | 01-JAN-09:15 | 1826.06 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 30.32 | 0.00 | 01-JAN-00:15 | 3949.37 | 13-SEP-15:15 |
EnergyTransfer:Zone:M S2 APARTMENT | 31.33 | 0.04 | 19-DEC-10:00 | 3956.44 | 02-SEP-13:15 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 1.01 | 0.00 | 01-JAN-09:15 | 1824.27 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 30.32 | 0.00 | 01-JAN-00:15 | 3956.44 | 02-SEP-13:15 |
EnergyTransfer:Zone:T SW APARTMENT | 24.11 | 0.02 | 23-MAY-04:30 | 3665.63 | 30-JUN-16:15 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 13.04 | 0.00 | 02-JAN-14:15 | 3589.62 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 11.08 | 0.00 | 01-JAN-00:15 | 3665.63 | 30-JUN-16:15 |
EnergyTransfer:Zone:T NW APARTMENT | 24.67 | 0.00 | 07-APR-22:15 | 3691.10 | 25-DEC-09:00 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 17.12 | 0.00 | 27-JAN-14:30 | 3691.10 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 7.55 | 0.00 | 01-JAN-00:15 | 3336.95 | 30-JUN-17:45 |
EnergyTransfer:Zone:T SE APARTMENT | 24.14 | 0.01 | 31-MAY-01:15 | 3551.88 | 25-DEC-09:00 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 12.88 | 0.00 | 02-JAN-14:30 | 3551.88 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 11.26 | 0.00 | 01-JAN-00:15 | 3467.77 | 10-AUG-13:45 |
EnergyTransfer:Zone:T NE APARTMENT | 24.67 | 0.00 | 18-SEP-02:00 | 3653.93 | 25-DEC-09:00 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 16.88 | 0.00 | 27-JAN-12:30 | 3653.93 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 7.79 | 0.00 | 01-JAN-00:15 | 2601.64 | 30-JUN-15:15 |
EnergyTransfer:Zone:T N1 APARTMENT | 17.24 | 0.04 | 18-MAY-13:30 | 2434.29 | 25-DEC-09:00 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 10.73 | 0.00 | 27-JAN-12:30 | 2434.29 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 6.51 | 0.00 | 01-JAN-00:15 | 2120.86 | 30-JUN-16:15 |
EnergyTransfer:Zone:T N2 APARTMENT | 17.26 | 0.00 | 11-OCT-02:15 | 2433.49 | 25-DEC-09:00 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 10.74 | 0.00 | 27-JAN-12:30 | 2433.49 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 6.52 | 0.00 | 01-JAN-00:15 | 2105.05 | 30-JUN-16:15 |
EnergyTransfer:Zone:T S1 APARTMENT | 17.40 | 0.01 | 25-MAY-02:00 | 2791.78 | 10-AUG-13:30 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 7.15 | 0.00 | 01-JAN-11:45 | 2326.49 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 10.25 | 0.00 | 01-JAN-00:15 | 2791.78 | 10-AUG-13:30 |
EnergyTransfer:Zone:T S2 APARTMENT | 17.43 | 0.03 | 01-OCT-04:30 | 2804.78 | 10-AUG-13:30 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 7.16 | 0.00 | 01-JAN-11:45 | 2325.55 | 25-DEC-09:00 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 10.27 | 0.00 | 01-JAN-00:15 | 2804.78 | 10-AUG-13:30 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:HVAC | 619.62 | 0.00 | 26-MAR-19:00 | 83853.71 | 25-DEC-09:00 |
HeatingCoils:EnergyTransfer | 334.86 | 0.00 | 18-MAR-15:45 | 83853.71 | 25-DEC-09:00 |
CoolingCoils:EnergyTransfer | 284.76 | 0.00 | 01-JAN-00:15 | 80234.65 | 10-AUG-15:30 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:55
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 6.354 | -5.939 | 0.000 | 0.000 | 3.884 | 1.087 | 12.213 | 14.133 | 0.000 | 0.112 | 0.000 | 0.000 | -8.988 | 0.000 | -5.712 | -17.143 |
G NW APARTMENT | 9.178 | -3.824 | 0.000 | 0.000 | 3.905 | 1.087 | 12.213 | 6.414 | 0.000 | 0.112 | 0.000 | 0.000 | -9.483 | 0.000 | -5.618 | -13.985 |
OFFICE | 2.255 | -19.179 | 0.000 | 0.000 | 0.525 | 26.452 | 9.482 | 13.969 | 0.000 | 0.062 | 0.001 | 0.000 | -8.745 | 0.000 | -5.192 | -19.628 |
G NE APARTMENT | 9.094 | -4.157 | 0.000 | 0.000 | 3.916 | 1.087 | 12.213 | 6.416 | 0.000 | 0.112 | 0.000 | 0.000 | -9.209 | 0.000 | -5.599 | -13.872 |
G N1 APARTMENT | 4.882 | -3.542 | 0.000 | 0.000 | 3.916 | 1.087 | 12.213 | 2.019 | 0.000 | 0.073 | 0.000 | 0.000 | -5.963 | 0.000 | -3.591 | -11.093 |
G N2 APARTMENT | 4.884 | -3.553 | 0.000 | 0.000 | 3.916 | 1.087 | 12.213 | 2.018 | 0.000 | 0.073 | 0.000 | 0.000 | -5.962 | 0.000 | -3.591 | -11.086 |
G S1 APARTMENT | 2.683 | -5.929 | 0.000 | 0.000 | 3.885 | 1.087 | 12.213 | 9.787 | 0.000 | 0.073 | 0.000 | 0.000 | -5.454 | 0.000 | -3.692 | -14.652 |
G S2 APARTMENT | 2.989 | -6.140 | 0.000 | 0.000 | 3.882 | 1.087 | 12.213 | 9.782 | 0.000 | 0.073 | 0.000 | 0.000 | -5.456 | 0.000 | -3.700 | -14.729 |
M SW APARTMENT | 5.701 | -27.489 | 0.000 | 0.000 | 3.776 | 1.087 | 12.213 | 13.687 | 0.000 | 0.157 | 8.854 | 0.000 | -9.651 | 0.000 | -8.334 | -0.000 |
M NW APARTMENT | 11.383 | -17.814 | 0.000 | 0.000 | 3.831 | 1.087 | 12.213 | 6.083 | 0.000 | 0.158 | 1.281 | 0.000 | -10.047 | 0.000 | -8.173 | -0.001 |
M SE APARTMENT | 5.769 | -28.456 | 0.000 | 0.000 | 3.782 | 1.087 | 12.213 | 13.699 | 0.000 | 0.157 | 9.445 | 0.000 | -9.371 | 0.000 | -8.326 | -0.000 |
M NE APARTMENT | 11.418 | -18.947 | 0.000 | 0.000 | 3.842 | 1.087 | 12.213 | 6.080 | 0.000 | 0.158 | 2.041 | 0.000 | -9.740 | 0.000 | -8.151 | -0.001 |
M N1 APARTMENT | 3.243 | -18.115 | 0.000 | 0.000 | 3.829 | 1.087 | 12.213 | 1.820 | 0.000 | 0.102 | 7.442 | 0.000 | -6.374 | 0.000 | -5.246 | -0.000 |
M N2 APARTMENT | 3.251 | -18.130 | 0.000 | 0.000 | 3.830 | 1.087 | 12.213 | 1.820 | 0.000 | 0.102 | 7.444 | 0.000 | -6.372 | 0.000 | -5.245 | -0.000 |
M S1 APARTMENT | 1.004 | -30.316 | 0.000 | 0.000 | 3.749 | 1.087 | 12.213 | 9.498 | 0.000 | 0.102 | 13.968 | 0.000 | -5.903 | 0.000 | -5.400 | -0.000 |
M S2 APARTMENT | 1.006 | -30.322 | 0.000 | 0.000 | 3.749 | 1.087 | 12.213 | 9.497 | 0.000 | 0.102 | 13.971 | 0.000 | -5.902 | 0.000 | -5.400 | -0.000 |
T SW APARTMENT | 13.037 | -11.077 | 0.000 | 0.000 | 3.841 | 1.087 | 12.213 | 13.634 | 0.000 | 0.208 | 0.000 | 0.000 | -9.151 | 0.000 | -10.702 | -13.088 |
T NW APARTMENT | 17.118 | -7.555 | 0.000 | 0.000 | 3.874 | 1.087 | 12.213 | 6.040 | 0.000 | 0.208 | 0.000 | 0.000 | -9.596 | 0.000 | -10.550 | -12.837 |
T SE APARTMENT | 12.880 | -11.260 | 0.000 | 0.000 | 3.846 | 1.087 | 12.213 | 13.671 | 0.000 | 0.208 | 0.000 | 0.000 | -8.902 | 0.000 | -10.699 | -13.044 |
T NE APARTMENT | 16.880 | -7.792 | 0.000 | 0.000 | 3.885 | 1.087 | 12.213 | 6.066 | 0.000 | 0.208 | 0.000 | 0.000 | -9.322 | 0.000 | -10.531 | -12.694 |
T N1 APARTMENT | 10.732 | -6.505 | 0.000 | 0.000 | 3.878 | 1.087 | 12.213 | 1.827 | 0.000 | 0.135 | 0.000 | 0.000 | -6.052 | 0.000 | -6.698 | -10.616 |
T N2 APARTMENT | 10.745 | -6.516 | 0.000 | 0.000 | 3.878 | 1.087 | 12.213 | 1.825 | 0.000 | 0.135 | 0.000 | 0.000 | -6.050 | 0.000 | -6.700 | -10.616 |
T S1 APARTMENT | 7.148 | -10.250 | 0.000 | 0.000 | 3.829 | 1.087 | 12.213 | 9.491 | 0.000 | 0.135 | 0.000 | 0.000 | -5.587 | 0.000 | -6.845 | -11.220 |
T S2 APARTMENT | 7.158 | -10.275 | 0.000 | 0.000 | 3.829 | 1.087 | 12.213 | 9.489 | 0.000 | 0.135 | 0.000 | 0.000 | -5.586 | 0.000 | -6.846 | -11.204 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 14.582 | 0.000 | 0.076 | 0.000 | 0.011 | 0.000 | 0.000 | -1.122 | 0.000 | -1.756 | -11.791 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 14.582 | 6.479 | 0.286 | 0.000 | 0.395 | 16.347 | 0.000 | -2.957 | 0.000 | -35.132 | -0.000 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 14.582 | 0.000 | 0.076 | 0.000 | 0.011 | 0.000 | 0.000 | -1.233 | 0.000 | -1.447 | -11.989 |
Total Facility | 180.793 | -313.080 | 0.000 | 0.000 | 89.077 | 95.189 | 296.854 | 189.202 | 0.000 | 3.514 | 80.793 | 0.000 | -188.179 | 0.000 | -198.875 | -235.289 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 10-AUG-16:13 | 0.00 | -2030.67 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2361.73 | 0.00 | 179.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1248.78 |
G NW APARTMENT | 21-JUL-17:25 | 0.00 | -1721.11 | 0.00 | 0.00 | 141.80 | 87.56 | 588.62 | 1983.07 | 0.00 | 127.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1207.35 |
OFFICE | 14-SEP-06:01 | 0.00 | -7725.94 | 0.00 | 0.00 | 0.00 | 416.15 | 294.31 | 73.47 | 0.00 | 0.00 | 6942.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G NE APARTMENT | 06-AUG-16:05 | 0.00 | -1205.18 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 575.85 | 0.00 | 247.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -356.20 |
G N1 APARTMENT | 21-JUL-18:00 | 0.00 | -894.08 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 378.72 | 0.00 | 69.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -371.67 |
G N2 APARTMENT | 21-JUL-18:00 | 0.00 | -883.69 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 378.89 | 0.00 | 69.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -382.22 |
G S1 APARTMENT | 02-SEP-13:15 | 0.00 | -1344.87 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 2190.16 | 0.00 | 80.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1361.83 |
G S2 APARTMENT | 02-SEP-13:15 | 0.00 | -1442.79 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 2188.73 | 0.00 | 80.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1262.48 |
M SW APARTMENT | 10-AUG-16:08 | 0.00 | -5598.60 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2342.19 | 0.00 | 257.34 | 2260.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NW APARTMENT | 30-JUN-18:00 | 0.00 | -5012.60 | 0.00 | 0.00 | 141.80 | 87.56 | 588.62 | 2129.37 | 0.00 | 228.37 | 1836.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M SE APARTMENT | 10-AUG-13:45 | 0.00 | -5195.28 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1860.63 | 0.00 | 399.47 | 2498.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NE APARTMENT | 18-JUN-17:00 | 0.00 | -3702.12 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 767.40 | 0.00 | 222.25 | 1974.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N1 APARTMENT | 30-JUN-18:30 | 0.00 | -2844.46 | 0.00 | 0.00 | 141.81 | 103.77 | 547.42 | 590.17 | 0.00 | 112.12 | 1349.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 30-JUN-18:30 | 0.00 | -2814.56 | 0.00 | 0.00 | 141.81 | 103.77 | 547.42 | 590.36 | 0.00 | 112.12 | 1319.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | 13-SEP-15:15 | 0.00 | -3948.46 | 0.00 | 0.00 | 48.90 | 45.40 | 470.90 | 1451.54 | 0.00 | 70.64 | 1861.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S2 APARTMENT | 02-SEP-13:15 | 0.00 | -3955.77 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 2177.50 | 0.00 | 107.34 | 1234.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SW APARTMENT | 30-JUN-16:08 | 0.00 | -3666.10 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 2103.25 | 0.00 | 434.93 | 389.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 30-JUN-17:45 | 0.00 | -3336.90 | 0.00 | 0.00 | 141.80 | 87.56 | 588.62 | 2098.85 | 0.00 | 301.49 | 118.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SE APARTMENT | 10-AUG-13:45 | 0.00 | -3467.61 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1828.29 | 0.00 | 525.94 | 677.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 30-JUN-15:15 | 0.00 | -2601.49 | 0.00 | 0.00 | 48.90 | 45.40 | 470.90 | 730.69 | 0.00 | 505.78 | 799.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 30-JUN-16:15 | 0.00 | -2121.80 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 420.61 | 0.00 | 262.35 | 700.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 30-JUN-16:15 | 0.00 | -2105.99 | 0.00 | 0.00 | 84.76 | 64.86 | 588.62 | 420.83 | 0.00 | 262.35 | 684.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 10-AUG-13:45 | 0.00 | -2791.61 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1555.47 | 0.00 | 317.24 | 482.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S2 APARTMENT | 10-AUG-13:30 | 0.00 | -2804.55 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1674.85 | 0.00 | 296.61 | 396.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 10-AUG-15:30 | 0.00 | -64324.69 | 0.00 | 0.00 | 1191.97 | 4512.09 | 11708.34 | 28983.35 | 0.00 | 6551.42 | 11377.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 25-DEC-08:53 | 1977.49 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -755.47 | 0.00 | -1038.62 | -665.31 |
G NW APARTMENT | 25-DEC-09:00 | 2071.07 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -851.84 | 0.00 | -1038.62 | -662.52 |
OFFICE | 28-NOV-07:01 | 5961.89 | 0.00 | 0.00 | 0.00 | 0.00 | 416.15 | 294.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -473.34 | 0.00 | -367.32 | -5831.70 |
G NE APARTMENT | 25-DEC-08:53 | 2042.78 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -784.04 | 0.00 | -1038.62 | -702.04 |
G N1 APARTMENT | 25-DEC-09:00 | 1257.70 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -517.53 | 0.00 | -626.47 | -595.62 |
G N2 APARTMENT | 25-DEC-09:00 | 1257.12 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -517.54 | 0.00 | -626.47 | -595.03 |
G S1 APARTMENT | 04-APR-06:01 | 1621.31 | 0.00 | 0.00 | 0.00 | 161.47 | 42.16 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -381.67 | 0.00 | 0.00 | -1825.87 |
G S2 APARTMENT | 23-OCT-06:01 | 1475.43 | 0.00 | 0.00 | 0.00 | 161.45 | 42.16 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -402.16 | 0.00 | -117.35 | -1542.13 |
M SW APARTMENT | 25-DEC-09:00 | 3957.78 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -783.32 | 0.00 | -1493.39 | -2162.99 |
M NW APARTMENT | 25-DEC-09:00 | 4335.41 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -879.80 | 0.00 | -1493.39 | -2444.14 |
M SE APARTMENT | 25-DEC-09:00 | 3886.01 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -714.09 | 0.00 | -1493.39 | -2160.45 |
M NE APARTMENT | 25-DEC-09:00 | 4266.06 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -810.57 | 0.00 | -1493.39 | -2444.03 |
M N1 APARTMENT | 11-FEB-08:01 | 2696.31 | 0.00 | 0.00 | 0.00 | 74.08 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -338.55 | 0.00 | -116.18 | -2723.60 |
M N2 APARTMENT | 13-NOV-17:01 | 2705.46 | 0.00 | 0.00 | 0.00 | 98.77 | 64.86 | 588.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -395.61 | 0.00 | -206.67 | -2855.43 |
M S1 APARTMENT | 16-JAN-01:55 | 2233.98 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 241.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -654.90 | 0.00 | 0.00 | -2016.57 |
M S2 APARTMENT | 10-MAR-07:01 | 1910.03 | 0.00 | 0.00 | 0.00 | 161.40 | 42.16 | 382.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -272.18 | 0.00 | -472.39 | -1751.62 |
T SW APARTMENT | 25-DEC-08:53 | 3589.58 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -760.11 | 0.00 | -1977.40 | -1333.99 |
T NW APARTMENT | 25-DEC-08:53 | 3691.05 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -859.43 | 0.00 | -1977.40 | -1336.14 |
T SE APARTMENT | 25-DEC-09:00 | 3552.00 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -690.07 | 0.00 | -1977.40 | -1366.44 |
T NE APARTMENT | 25-DEC-08:53 | 3653.96 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -789.42 | 0.00 | -1977.40 | -1369.07 |
T N1 APARTMENT | 25-DEC-09:00 | 2434.61 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -522.44 | 0.00 | -1192.76 | -1201.33 |
T N2 APARTMENT | 25-DEC-09:00 | 2433.81 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -522.45 | 0.00 | -1192.76 | -1200.52 |
T S1 APARTMENT | 25-DEC-08:53 | 2326.60 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -422.95 | 0.00 | -1192.76 | -1192.80 |
T S2 APARTMENT | 25-DEC-08:53 | 2325.66 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -422.97 | 0.00 | -1192.76 | -1191.85 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 25-DEC-09:00 | 59107.32 | 0.00 | 0.00 | 0.00 | 1701.35 | 2250.82 | 9539.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -15385.43 | 0.00 | -32236.74 | -24976.31 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:55
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:55
Sec1.1A-General InformationData | |
Weather File | Helena Regional Airport MT USA TMY3 WMO#=727720 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 3134.61 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.32 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 3134.61 | 2823.98 | 310.64 |
Data | |
Number of hours heating loads not met | 40.75 |
Number of hours cooling loads not met | 0.50 |
Number of hours not met | 41.25 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 118.46 | 4979.95 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 40.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 0.00 | 0.00 | 418.58 | 104817.13 | 0.00 | 0.00 |
Space Cooling | 73.03 | 18090.85 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 256.97 | 8148.48 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 434.73 | 24991.60 | 0.00 | 0.00 | 0.00 | 0.00 |
Receptacle Equipment | 517.65 | 26630.92 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 1440.89 | 418.58 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 517.65 | 1440.89 |
Natural Gas | 0.00 | 418.58 |
Additional | 0.00 | 0.00 |
Total | 517.65 | 1859.47 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 37.79 |
Space Heating | 0.00 |
Space Cooling | 23.30 |
Fans-Interior | 81.98 |
Service Water Heating | 138.69 |
Receptacle Equipment | 165.14 |
Miscellaneous | 12.78 |
Subtotal | 459.67 |
Natural Gas [MJ/m2] | |
Space Heating | 133.53 |
Service Water Heating | 0.00 |
Miscellaneous | 0.00 |
Subtotal | 133.53 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 6.37 |
Space Heating | 22.51 |
Space Cooling | 3.93 |
Fans-Interior | 13.82 |
Service Water Heating | 23.38 |
Receptacle Equipment | 27.84 |
Miscellaneous | 2.15 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:55
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.194722 |
G NW APARTMENT DIRECT AIR | 0.176376 |
OFFICE DIRECT AIR | 0.511718 |
G NE APARTMENT DIRECT AIR | 0.123281 |
G N1 APARTMENT DIRECT AIR | 0.094951 |
G N2 APARTMENT DIRECT AIR | 0.093626 |
G S1 APARTMENT DIRECT AIR | 0.128279 |
G S2 APARTMENT DIRECT AIR | 0.131848 |
M SW APARTMENT DIRECT AIR | 0.547365 |
M NW APARTMENT DIRECT AIR | 0.491707 |
M SE APARTMENT DIRECT AIR | 0.504908 |
M NE APARTMENT DIRECT AIR | 0.380507 |
M N1 APARTMENT DIRECT AIR | 0.285710 |
M N2 APARTMENT DIRECT AIR | 0.283467 |
M S1 APARTMENT DIRECT AIR | 0.379223 |
M S2 APARTMENT DIRECT AIR | 0.380663 |
T SW APARTMENT DIRECT AIR | 0.374417 |
T NW APARTMENT DIRECT AIR | 0.329270 |
T SE APARTMENT DIRECT AIR | 0.351459 |
T NE APARTMENT DIRECT AIR | 0.267448 |
T N1 APARTMENT DIRECT AIR | 0.206914 |
T N2 APARTMENT DIRECT AIR | 0.206917 |
T S1 APARTMENT DIRECT AIR | 0.286866 |
T S2 APARTMENT DIRECT AIR | 0.287828 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW MAIN BRANCH | 0.194722 |
SPLIT GNW MAIN BRANCH | 0.176376 |
SPLIT OFFICE MAIN BRANCH | 0.511718 |
SPLIT GNE MAIN BRANCH | 0.123281 |
SPLIT GN1 MAIN BRANCH | 0.094951 |
SPLIT GN2 MAIN BRANCH | 0.093626 |
SPLIT GS1 MAIN BRANCH | 0.128279 |
SPLIT GS2 MAIN BRANCH | 0.131848 |
SPLIT MSW MAIN BRANCH | 0.547365 |
SPLIT MNW MAIN BRANCH | 0.491707 |
SPLIT MSE MAIN BRANCH | 0.504908 |
SPLIT MNE MAIN BRANCH | 0.380507 |
SPLIT MN1 MAIN BRANCH | 0.285710 |
SPLIT MN2 MAIN BRANCH | 0.283467 |
SPLIT MS1 MAIN BRANCH | 0.379223 |
SPLIT MS2 MAIN BRANCH | 0.380663 |
SPLIT TSW MAIN BRANCH | 0.374417 |
SPLIT TNW MAIN BRANCH | 0.329270 |
SPLIT TSE MAIN BRANCH | 0.351459 |
SPLIT TNE MAIN BRANCH | 0.267448 |
SPLIT TN1 MAIN BRANCH | 0.206914 |
SPLIT TN2 MAIN BRANCH | 0.206917 |
SPLIT TS1 MAIN BRANCH | 0.286866 |
SPLIT TS2 MAIN BRANCH | 0.287828 |
Design Supply Air Flow Rate [m3/s] | |
SPLIT GSW | 0.194722 |
SPLIT GNW | 0.176376 |
SPLIT OFFICE | 0.511718 |
SPLIT GNE | 0.123281 |
SPLIT GN1 | 0.094951 |
SPLIT GN2 | 0.093626 |
SPLIT GS1 | 0.128279 |
SPLIT GS2 | 0.131848 |
SPLIT MSW | 0.547365 |
SPLIT MNW | 0.491707 |
SPLIT MSE | 0.504908 |
SPLIT MNE | 0.380507 |
SPLIT MN1 | 0.285710 |
SPLIT MN2 | 0.283467 |
SPLIT MS1 | 0.379223 |
SPLIT MS2 | 0.380663 |
SPLIT TSW | 0.374417 |
SPLIT TNW | 0.329270 |
SPLIT TSE | 0.351459 |
SPLIT TNE | 0.267448 |
SPLIT TN1 | 0.206914 |
SPLIT TN2 | 0.206917 |
SPLIT TS1 | 0.286866 |
SPLIT TS2 | 0.287828 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
SPLIT GSW OA CONTROLLER | 0.194722 | 0.026898 |
SPLIT GNW OA CONTROLLER | 0.176376 | 0.025953 |
SPLIT OFFICE OA CONTROLLER | 0.511718 | 0.038104 |
SPLIT GNE OA CONTROLLER | 0.123281 | 0.025953 |
SPLIT GN1 OA CONTROLLER | 0.094951 | 0.025953 |
SPLIT GN2 OA CONTROLLER | 0.093626 | 0.025953 |
SPLIT GS1 OA CONTROLLER | 0.128279 | 0.025953 |
SPLIT GS2 OA CONTROLLER | 0.131848 | 0.025953 |
SPLIT MSW OA CONTROLLER | 0.547365 | 0.051906 |
SPLIT MNW OA CONTROLLER | 0.491707 | 0.051906 |
SPLIT MSE OA CONTROLLER | 0.504908 | 0.051906 |
SPLIT MNE OA CONTROLLER | 0.380507 | 0.051906 |
SPLIT MN1 OA CONTROLLER | 0.285710 | 0.051906 |
SPLIT MN2 OA CONTROLLER | 0.283467 | 0.051906 |
SPLIT MS1 OA CONTROLLER | 0.379223 | 0.051906 |
SPLIT MS2 OA CONTROLLER | 0.380663 | 0.051906 |
SPLIT TSW OA CONTROLLER | 0.374417 | 0.025953 |
SPLIT TNW OA CONTROLLER | 0.329270 | 0.025953 |
SPLIT TSE OA CONTROLLER | 0.351459 | 0.025953 |
SPLIT TNE OA CONTROLLER | 0.267448 | 0.025953 |
SPLIT TN1 OA CONTROLLER | 0.206914 | 0.025953 |
SPLIT TN2 OA CONTROLLER | 0.206917 | 0.025953 |
SPLIT TS1 OA CONTROLLER | 0.286866 | 0.025953 |
SPLIT TS2 OA CONTROLLER | 0.287828 | 0.025953 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity (gross) [W] | Rated Sensible Heat Ratio | |
SPLIT GSW COOLING COIL | 0.194722 | 3223.35 | 0.798655 |
SPLIT GNW COOLING COIL | 0.176376 | 2919.64 | 0.798655 |
SPLIT OFFICE COOLING COIL | 0.511718 | 8470.75 | 0.798655 |
SPLIT GNE COOLING COIL | 0.123281 | 2040.74 | 0.798655 |
SPLIT GN1 COOLING COIL | 0.094951 | 1571.78 | 0.798655 |
SPLIT GN2 COOLING COIL | 0.093626 | 1549.85 | 0.798655 |
SPLIT GS1 COOLING COIL | 0.128279 | 2123.47 | 0.798655 |
SPLIT GS2 COOLING COIL | 0.131848 | 2182.55 | 0.798655 |
SPLIT MSW COOLING COIL | 0.547365 | 9060.84 | 0.798655 |
SPLIT MNW COOLING COIL | 0.491707 | 8139.50 | 0.798655 |
SPLIT MSE COOLING COIL | 0.504908 | 8358.03 | 0.798655 |
SPLIT MNE COOLING COIL | 0.380507 | 6298.75 | 0.798655 |
SPLIT MN1 COOLING COIL | 0.285710 | 4729.52 | 0.798655 |
SPLIT MN2 COOLING COIL | 0.283467 | 4692.38 | 0.798655 |
SPLIT MS1 COOLING COIL | 0.379223 | 6277.49 | 0.798655 |
SPLIT MS2 COOLING COIL | 0.380663 | 6301.33 | 0.798655 |
SPLIT TSW COOLING COIL | 0.374417 | 6197.92 | 0.798655 |
SPLIT TNW COOLING COIL | 0.329270 | 5450.59 | 0.798655 |
SPLIT TSE COOLING COIL | 0.351459 | 5817.90 | 0.798655 |
SPLIT TNE COOLING COIL | 0.267448 | 4427.21 | 0.798655 |
SPLIT TN1 COOLING COIL | 0.206914 | 3425.15 | 0.798655 |
SPLIT TN2 COOLING COIL | 0.206917 | 3425.20 | 0.798655 |
SPLIT TS1 COOLING COIL | 0.286866 | 4748.65 | 0.798655 |
SPLIT TS2 COOLING COIL | 0.287828 | 4764.57 | 0.798655 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
SPLIT GSW FURNACE WITH DX COOLING | 0.194722 | 0.194722 | 0.194722 | 0.194722 | 3677.46 | 3223.35 | 1.00 |
SPLIT GNW FURNACE WITH DX COOLING | 0.176376 | 0.176376 | 0.176376 | 0.176376 | 3646.64 | 2919.64 | 1.00 |
SPLIT OFFICE FURNACE WITH DX COOLING | 0.511718 | 0.511718 | 0.511718 | 0.511718 | 6389.14 | 8470.75 | 1.00 |
SPLIT GNE FURNACE WITH DX COOLING | 0.123281 | 0.123281 | 0.123281 | 0.123281 | 3637.61 | 2040.74 | 1.00 |
SPLIT GN1 FURNACE WITH DX COOLING | 0.094951 | 0.094951 | 0.094951 | 0.094951 | 2830.30 | 1571.78 | 1.00 |
SPLIT GN2 FURNACE WITH DX COOLING | 0.093626 | 0.093626 | 0.093626 | 0.093626 | 2830.09 | 1549.85 | 1.00 |
SPLIT GS1 FURNACE WITH DX COOLING | 0.128279 | 0.128279 | 0.128279 | 0.128279 | 2816.84 | 2123.47 | 1.00 |
SPLIT GS2 FURNACE WITH DX COOLING | 0.131848 | 0.131848 | 0.131848 | 0.131848 | 2950.70 | 2182.55 | 1.00 |
SPLIT MSW FURNACE WITH DX COOLING | 0.547365 | 0.547365 | 0.547365 | 0.547365 | 6845.21 | 9060.84 | 1.00 |
SPLIT MNW FURNACE WITH DX COOLING | 0.491707 | 0.491707 | 0.491707 | 0.491707 | 6885.27 | 8139.50 | 1.00 |
SPLIT MSE FURNACE WITH DX COOLING | 0.504908 | 0.504908 | 0.504908 | 0.504908 | 6821.26 | 8358.03 | 1.00 |
SPLIT MNE FURNACE WITH DX COOLING | 0.380507 | 0.380507 | 0.380507 | 0.380507 | 6861.30 | 6298.75 | 1.00 |
SPLIT MN1 FURNACE WITH DX COOLING | 0.285710 | 0.285710 | 0.285710 | 0.285710 | 4888.65 | 4729.52 | 1.00 |
SPLIT MN2 FURNACE WITH DX COOLING | 0.283467 | 0.283467 | 0.283467 | 0.283467 | 4888.07 | 4692.38 | 1.00 |
SPLIT MS1 FURNACE WITH DX COOLING | 0.379223 | 0.379223 | 0.379223 | 0.379223 | 4851.33 | 6277.49 | 1.00 |
SPLIT MS2 FURNACE WITH DX COOLING | 0.380663 | 0.380663 | 0.380663 | 0.380663 | 4850.75 | 6301.33 | 1.00 |
SPLIT TSW FURNACE WITH DX COOLING | 0.374417 | 0.374417 | 0.374417 | 0.374417 | 5194.76 | 6197.92 | 1.00 |
SPLIT TNW FURNACE WITH DX COOLING | 0.329270 | 0.329270 | 0.329270 | 0.329270 | 5218.05 | 5450.59 | 1.00 |
SPLIT TSE FURNACE WITH DX COOLING | 0.351459 | 0.351459 | 0.351459 | 0.351459 | 5181.93 | 5817.90 | 1.00 |
SPLIT TNE FURNACE WITH DX COOLING | 0.267448 | 0.267448 | 0.267448 | 0.267448 | 5205.22 | 4427.21 | 1.00 |
SPLIT TN1 FURNACE WITH DX COOLING | 0.206914 | 0.206914 | 0.206914 | 0.206914 | 4176.00 | 3425.15 | 1.00 |
SPLIT TN2 FURNACE WITH DX COOLING | 0.206917 | 0.206917 | 0.206917 | 0.206917 | 4175.67 | 3425.20 | 1.00 |
SPLIT TS1 FURNACE WITH DX COOLING | 0.286866 | 0.286866 | 0.286866 | 0.286866 | 4151.02 | 4748.65 | 1.00 |
SPLIT TS2 FURNACE WITH DX COOLING | 0.287828 | 0.287828 | 0.287828 | 0.287828 | 4150.69 | 4764.57 | 1.00 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW SUPPLY FAN | 0.194722 |
SPLIT GNW SUPPLY FAN | 0.176376 |
SPLIT OFFICE SUPPLY FAN | 0.511718 |
SPLIT GNE SUPPLY FAN | 0.123281 |
SPLIT GN1 SUPPLY FAN | 0.094951 |
SPLIT GN2 SUPPLY FAN | 0.093626 |
SPLIT GS1 SUPPLY FAN | 0.128279 |
SPLIT GS2 SUPPLY FAN | 0.131848 |
SPLIT MSW SUPPLY FAN | 0.547365 |
SPLIT MNW SUPPLY FAN | 0.491707 |
SPLIT MSE SUPPLY FAN | 0.504908 |
SPLIT MNE SUPPLY FAN | 0.380507 |
SPLIT MN1 SUPPLY FAN | 0.285710 |
SPLIT MN2 SUPPLY FAN | 0.283467 |
SPLIT MS1 SUPPLY FAN | 0.379223 |
SPLIT MS2 SUPPLY FAN | 0.380663 |
SPLIT TSW SUPPLY FAN | 0.374417 |
SPLIT TNW SUPPLY FAN | 0.329270 |
SPLIT TSE SUPPLY FAN | 0.351459 |
SPLIT TNE SUPPLY FAN | 0.267448 |
SPLIT TN1 SUPPLY FAN | 0.206914 |
SPLIT TN2 SUPPLY FAN | 0.206917 |
SPLIT TS1 SUPPLY FAN | 0.286866 |
SPLIT TS2 SUPPLY FAN | 0.287828 |
Nominal Capacity [W] | |
SPLIT GSW HEATING COIL | 3677.46 |
SPLIT GNW HEATING COIL | 3646.64 |
SPLIT OFFICE HEATING COIL | 6389.14 |
SPLIT GNE HEATING COIL | 3637.61 |
SPLIT GN1 HEATING COIL | 2830.30 |
SPLIT GN2 HEATING COIL | 2830.09 |
SPLIT GS1 HEATING COIL | 2816.84 |
SPLIT GS2 HEATING COIL | 2950.70 |
SPLIT MSW HEATING COIL | 6845.21 |
SPLIT MNW HEATING COIL | 6885.27 |
SPLIT MSE HEATING COIL | 6821.26 |
SPLIT MNE HEATING COIL | 6861.30 |
SPLIT MN1 HEATING COIL | 4888.65 |
SPLIT MN2 HEATING COIL | 4888.07 |
SPLIT MS1 HEATING COIL | 4851.33 |
SPLIT MS2 HEATING COIL | 4850.75 |
SPLIT TSW HEATING COIL | 5194.76 |
SPLIT TNW HEATING COIL | 5218.05 |
SPLIT TSE HEATING COIL | 5181.93 |
SPLIT TNE HEATING COIL | 5205.22 |
SPLIT TN1 HEATING COIL | 4176.00 |
SPLIT TN2 HEATING COIL | 4175.67 |
SPLIT TS1 HEATING COIL | 4151.02 |
SPLIT TS2 HEATING COIL | 4150.69 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:55
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW1 S SWA | |
G WWALL SWA | GWINDOW1 W SWA | |
G NWALL NWA | GWINDOW1 N NWA | |
G WWALL NWA | GWINDOW1 W NWA | |
G SWALL SEA | GWINDOW1 S SEA | |
G EWALL SEA | GWINDOW1 E SEA | |
G NWALL NEA | GWINDOW1 N NEA | |
G EWALL NEA | GWINDOW1 E NEA | |
G NWALL N1A | GWINDOW1 N N1A | |
G NWALL N2A | GWINDOW1 N N2A | |
G SWALL S1A | GWINDOW1 S S1A | |
G SWALL S2A | GWINDOW1 S S2A | |
M WWALL SWA | MWINDOW1 W SWA | |
M SWALL SWA | MWINDOW1 S SWA | |
M NWALL NWA | MWINDOW1 N NWA | |
M WWALL NWA | MWINDOW1 W NWA | |
M EWALL SEA | MWINDOW1 E SEA | |
M SWALL SEA | MWINDOW1 S SEA | |
M NWALL NEA | MWINDOW1 N NEA | |
M EWALL NEA | MWINDOW1 E NEA | |
M NWALL N1A | MWINDOW1 N N1A | |
M NWALL N2A | MWINDOW1 N N2A | |
M SWALL S1A | MWINDOW1 S S1A | |
M SWALL S2A | MWINDOW1 S S2A | |
T WWALL SWA | TWINDOW1 W SWA | |
T SWALL SWA | TWINDOW1 S SWA | |
T NWALL NWA | TWINDOW1 N NWA | |
T WWALL NWA | TWINDOW1 W NWA | |
T EWALL SEA | TWINDOW1 E SEA | |
T SWALL SEA | TWINDOW1 S SEA | |
T NWALL NEA | TWINDOW1 N NEA | |
T EWALL NEA | TWINDOW1 E NEA | |
T NWALL N1A | TWINDOW1 N N1A | |
T NWALL N2A | TWINDOW1 N N2A | |
T SWALL S1A | TWINDOW1 S S1A | |
T SWALL S2A | TWINDOW1 S S2A | |
T EWALL C | TWINDOW14 | |
G EWALL C | ENTRANCE DOOR | |
M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:55
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -4.7 |
February | 21.74 | -3.7 |
March | 21.88 | 2.15 |
April | 22.18 | 6.19 |
May | 22.67 | 11.83 |
June | 24.07 | 17.35 |
July | 24.35 | 20.52 |
August | 24.28 | 18.54 |
September | 24.01 | 14.70 |
October | 22.33 | 6.26 |
November | 21.81 | 1.12 |
December | 21.72 | -5.0 |
Annual Sum or Average | 22.73 | 7.16 |
Minimum of Months | 21.71 | -5.0 |
Maximum of Months | 24.35 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.73 | 2.15 |
April | 21.90 | 6.19 |
May | 22.46 | 11.83 |
June | 24.02 | 17.35 |
July | 24.34 | 20.52 |
August | 24.22 | 18.54 |
September | 23.78 | 14.70 |
October | 21.89 | 6.26 |
November | 21.71 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.60 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.34 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.14 | -4.7 |
February | 20.59 | -3.7 |
March | 21.69 | 2.15 |
April | 22.63 | 6.19 |
May | 23.73 | 11.83 |
June | 25.58 | 17.35 |
July | 26.40 | 20.52 |
August | 26.01 | 18.54 |
September | 25.66 | 14.70 |
October | 22.97 | 6.26 |
November | 21.41 | 1.12 |
December | 19.96 | -5.0 |
Annual Sum or Average | 23.08 | 7.16 |
Minimum of Months | 19.96 | -5.0 |
Maximum of Months | 26.40 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.71 | 2.15 |
April | 21.84 | 6.19 |
May | 22.42 | 11.83 |
June | 23.97 | 17.35 |
July | 24.32 | 20.52 |
August | 24.19 | 18.54 |
September | 23.69 | 14.70 |
October | 21.82 | 6.26 |
November | 21.70 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.57 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.32 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.71 | 2.15 |
April | 21.79 | 6.19 |
May | 22.23 | 11.83 |
June | 23.92 | 17.35 |
July | 24.31 | 20.52 |
August | 24.19 | 18.54 |
September | 23.75 | 14.70 |
October | 21.82 | 6.26 |
November | 21.70 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.55 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.31 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.71 | 2.15 |
April | 21.79 | 6.19 |
May | 22.22 | 11.83 |
June | 23.91 | 17.35 |
July | 24.31 | 20.52 |
August | 24.19 | 18.54 |
September | 23.74 | 14.70 |
October | 21.82 | 6.26 |
November | 21.70 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.55 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.31 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -4.7 |
February | 21.73 | -3.7 |
March | 21.86 | 2.15 |
April | 22.11 | 6.19 |
May | 22.53 | 11.83 |
June | 24.06 | 17.35 |
July | 24.35 | 20.52 |
August | 24.30 | 18.54 |
September | 24.10 | 14.70 |
October | 22.37 | 6.26 |
November | 21.83 | 1.12 |
December | 21.73 | -5.0 |
Annual Sum or Average | 22.73 | 7.16 |
Minimum of Months | 21.71 | -5.0 |
Maximum of Months | 24.35 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -4.7 |
February | 21.73 | -3.7 |
March | 21.86 | 2.15 |
April | 22.13 | 6.19 |
May | 22.58 | 11.83 |
June | 24.09 | 17.35 |
July | 24.36 | 20.52 |
August | 24.31 | 18.54 |
September | 24.12 | 14.70 |
October | 22.39 | 6.26 |
November | 21.83 | 1.12 |
December | 21.73 | -5.0 |
Annual Sum or Average | 22.74 | 7.16 |
Minimum of Months | 21.71 | -5.0 |
Maximum of Months | 24.36 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.80 | -4.7 |
February | 21.99 | -3.7 |
March | 22.51 | 2.15 |
April | 23.29 | 6.19 |
May | 24.03 | 11.83 |
June | 24.39 | 17.35 |
July | 24.40 | 20.52 |
August | 24.40 | 18.54 |
September | 24.34 | 14.70 |
October | 23.50 | 6.26 |
November | 22.30 | 1.12 |
December | 21.83 | -5.0 |
Annual Sum or Average | 23.24 | 7.16 |
Minimum of Months | 21.80 | -5.0 |
Maximum of Months | 24.40 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.71 | -3.7 |
March | 21.88 | 2.15 |
April | 22.68 | 6.19 |
May | 23.79 | 11.83 |
June | 24.39 | 17.35 |
July | 24.40 | 20.52 |
August | 24.39 | 18.54 |
September | 24.23 | 14.70 |
October | 22.56 | 6.26 |
November | 21.81 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.94 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.40 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.79 | -4.7 |
February | 21.94 | -3.7 |
March | 22.46 | 2.15 |
April | 23.29 | 6.19 |
May | 24.03 | 11.83 |
June | 24.39 | 17.35 |
July | 24.40 | 20.52 |
August | 24.40 | 18.54 |
September | 24.33 | 14.70 |
October | 23.47 | 6.26 |
November | 22.25 | 1.12 |
December | 21.82 | -5.0 |
Annual Sum or Average | 23.22 | 7.16 |
Minimum of Months | 21.79 | -5.0 |
Maximum of Months | 24.40 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.83 | 2.15 |
April | 22.59 | 6.19 |
May | 23.72 | 11.83 |
June | 24.37 | 17.35 |
July | 24.40 | 20.52 |
August | 24.39 | 18.54 |
September | 24.18 | 14.70 |
October | 22.44 | 6.26 |
November | 21.77 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.91 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.40 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.86 | 2.15 |
April | 22.64 | 6.19 |
May | 23.83 | 11.83 |
June | 24.39 | 17.35 |
July | 24.40 | 20.52 |
August | 24.40 | 18.54 |
September | 24.28 | 14.70 |
October | 22.63 | 6.26 |
November | 21.84 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.95 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.40 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.85 | 2.15 |
April | 22.63 | 6.19 |
May | 23.82 | 11.83 |
June | 24.39 | 17.35 |
July | 24.40 | 20.52 |
August | 24.40 | 18.54 |
September | 24.27 | 14.70 |
October | 22.62 | 6.26 |
November | 21.83 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.95 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.40 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.90 | -4.7 |
February | 22.15 | -3.7 |
March | 22.74 | 2.15 |
April | 23.51 | 6.19 |
May | 24.16 | 11.83 |
June | 24.40 | 17.35 |
July | 24.40 | 20.52 |
August | 24.40 | 18.54 |
September | 24.38 | 14.70 |
October | 23.80 | 6.26 |
November | 22.59 | 1.12 |
December | 21.96 | -5.0 |
Annual Sum or Average | 23.37 | 7.16 |
Minimum of Months | 21.90 | -5.0 |
Maximum of Months | 24.40 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.90 | -4.7 |
February | 22.15 | -3.7 |
March | 22.74 | 2.15 |
April | 23.52 | 6.19 |
May | 24.16 | 11.83 |
June | 24.40 | 17.35 |
July | 24.40 | 20.52 |
August | 24.40 | 18.54 |
September | 24.38 | 14.70 |
October | 23.80 | 6.26 |
November | 22.58 | 1.12 |
December | 21.96 | -5.0 |
Annual Sum or Average | 23.37 | 7.16 |
Minimum of Months | 21.90 | -5.0 |
Maximum of Months | 24.40 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.79 | -4.7 |
February | 21.91 | -3.7 |
March | 22.22 | 2.15 |
April | 22.79 | 6.19 |
May | 23.47 | 11.83 |
June | 24.22 | 17.35 |
July | 24.36 | 20.52 |
August | 24.28 | 18.54 |
September | 23.91 | 14.70 |
October | 22.69 | 6.26 |
November | 22.02 | 1.12 |
December | 21.79 | -5.0 |
Annual Sum or Average | 22.96 | 7.16 |
Minimum of Months | 21.79 | -5.0 |
Maximum of Months | 24.36 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.71 | -3.7 |
March | 21.87 | 2.15 |
April | 22.43 | 6.19 |
May | 23.31 | 11.83 |
June | 24.18 | 17.35 |
July | 24.35 | 20.52 |
August | 24.22 | 18.54 |
September | 23.67 | 14.70 |
October | 22.19 | 6.26 |
November | 21.75 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.76 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.35 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.77 | -4.7 |
February | 21.88 | -3.7 |
March | 22.19 | 2.15 |
April | 22.82 | 6.19 |
May | 23.50 | 11.83 |
June | 24.21 | 17.35 |
July | 24.36 | 20.52 |
August | 24.28 | 18.54 |
September | 23.90 | 14.70 |
October | 22.71 | 6.26 |
November | 22.00 | 1.12 |
December | 21.78 | -5.0 |
Annual Sum or Average | 22.96 | 7.16 |
Minimum of Months | 21.77 | -5.0 |
Maximum of Months | 24.36 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.82 | 2.15 |
April | 22.38 | 6.19 |
May | 23.31 | 11.83 |
June | 24.13 | 17.35 |
July | 24.33 | 20.52 |
August | 24.19 | 18.54 |
September | 23.63 | 14.70 |
October | 22.11 | 6.26 |
November | 21.73 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.73 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.33 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.81 | 2.15 |
April | 22.34 | 6.19 |
May | 23.30 | 11.83 |
June | 24.19 | 17.35 |
July | 24.35 | 20.52 |
August | 24.23 | 18.54 |
September | 23.66 | 14.70 |
October | 22.09 | 6.26 |
November | 21.74 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.74 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.35 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.7 |
February | 21.70 | -3.7 |
March | 21.81 | 2.15 |
April | 22.34 | 6.19 |
May | 23.31 | 11.83 |
June | 24.19 | 17.35 |
July | 24.35 | 20.52 |
August | 24.23 | 18.54 |
September | 23.66 | 14.70 |
October | 22.09 | 6.26 |
November | 21.74 | 1.12 |
December | 21.70 | -5.0 |
Annual Sum or Average | 22.74 | 7.16 |
Minimum of Months | 21.70 | -5.0 |
Maximum of Months | 24.35 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.81 | -4.7 |
February | 21.92 | -3.7 |
March | 22.27 | 2.15 |
April | 22.88 | 6.19 |
May | 23.57 | 11.83 |
June | 24.26 | 17.35 |
July | 24.38 | 20.52 |
August | 24.32 | 18.54 |
September | 24.01 | 14.70 |
October | 22.80 | 6.26 |
November | 22.09 | 1.12 |
December | 21.82 | -5.0 |
Annual Sum or Average | 23.02 | 7.16 |
Minimum of Months | 21.81 | -5.0 |
Maximum of Months | 24.38 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.81 | -4.7 |
February | 21.92 | -3.7 |
March | 22.27 | 2.15 |
April | 22.88 | 6.19 |
May | 23.57 | 11.83 |
June | 24.26 | 17.35 |
July | 24.38 | 20.52 |
August | 24.32 | 18.54 |
September | 24.01 | 14.70 |
October | 22.80 | 6.26 |
November | 22.09 | 1.12 |
December | 21.82 | -5.0 |
Annual Sum or Average | 23.02 | 7.16 |
Minimum of Months | 21.81 | -5.0 |
Maximum of Months | 24.38 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.64 | -4.7 |
February | 21.03 | -3.7 |
March | 21.91 | 2.15 |
April | 23.06 | 6.19 |
May | 24.55 | 11.83 |
June | 25.99 | 17.35 |
July | 26.48 | 20.52 |
August | 26.10 | 18.54 |
September | 25.17 | 14.70 |
October | 22.73 | 6.26 |
November | 21.43 | 1.12 |
December | 20.58 | -5.0 |
Annual Sum or Average | 23.32 | 7.16 |
Minimum of Months | 20.58 | -5.0 |
Maximum of Months | 26.48 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 17.97 | -4.7 |
February | 18.22 | -3.7 |
March | 19.49 | 2.15 |
April | 20.51 | 6.19 |
May | 21.99 | 11.83 |
June | 24.59 | 17.35 |
July | 25.73 | 20.52 |
August | 25.25 | 18.54 |
September | 24.23 | 14.70 |
October | 20.78 | 6.26 |
November | 19.30 | 1.12 |
December | 17.92 | -5.0 |
Annual Sum or Average | 21.35 | 7.16 |
Minimum of Months | 17.92 | -5.0 |
Maximum of Months | 25.73 | 20.52 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2015-09-09 18:47:55
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.76 | -4.7 |
February | 23.07 | -3.7 |
March | 23.71 | 2.15 |
April | 24.69 | 6.19 |
May | 25.85 | 11.83 |
June | 26.62 | 17.35 |
July | 26.81 | 20.52 |
August | 26.68 | 18.54 |
September | 26.39 | 14.70 |
October | 24.80 | 6.26 |
November | 23.44 | 1.12 |
December | 22.73 | -5.0 |
Annual Sum or Average | 24.81 | 7.16 |
Minimum of Months | 22.73 | -5.0 |
Maximum of Months | 26.81 | 20.52 |
Report: PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2015-09-09 18:47:55
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [Invalid/Undefined] | HEATREJECTION:ELECTRICITY [Invalid/Undefined] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined] | |
January | 0.120325E+12 | 74694.157 | 22-JAN-18:15 | 4979.953 | 26630.920 | 8148.477 | 0.000 | 0.000 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32381.806 | 0.000 | 0.000 | 0.000 |
February | 0.108938E+12 | 73704.475 | 28-FEB-18:30 | 4979.953 | 26630.920 | 8148.477 | 0.000 | 0.000 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 31392.124 | 0.000 | 0.000 | 0.000 |
March | 0.120289E+12 | 72524.561 | 01-MAR-18:45 | 4979.953 | 26630.920 | 8148.477 | 0.000 | 0.000 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 30212.210 | 0.000 | 0.000 | 0.000 |
April | 0.115867E+12 | 72944.610 | 08-APR-17:00 | 4979.953 | 26630.920 | 8148.477 | 0.000 | 5040.029 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 28145.230 | 0.000 | 0.000 | 0.000 |
May | 0.121210E+12 | 77201.995 | 26-MAY-17:45 | 4979.953 | 26630.920 | 8148.477 | 0.000 | 13492.489 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23950.155 | 0.000 | 0.000 | 0.000 |
June | 0.123936E+12 | 80369.945 | 30-JUN-17:15 | 4979.953 | 26630.920 | 8148.477 | 0.000 | 19409.899 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 21200.695 | 0.000 | 0.000 | 0.000 |
July | 0.133089E+12 | 82841.806 | 19-JUL-17:15 | 4979.953 | 26630.920 | 8148.477 | 0.000 | 18090.855 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 24991.600 | 0.000 | 0.000 | 0.000 |
August | 0.128928E+12 | 82774.096 | 10-AUG-17:15 | 4979.953 | 26630.920 | 8148.477 | 0.000 | 19100.997 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23913.748 | 0.000 | 0.000 | 0.000 |
September | 0.119615E+12 | 79435.571 | 15-SEP-17:00 | 4979.953 | 26630.920 | 8148.477 | 0.000 | 15937.966 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23738.254 | 0.000 | 0.000 | 0.000 |
October | 0.116493E+12 | 70938.125 | 09-OCT-17:30 | 4979.953 | 26630.920 | 8148.477 | 0.000 | 3981.151 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 27197.623 | 0.000 | 0.000 | 0.000 |
November | 0.113273E+12 | 70781.435 | 10-NOV-18:45 | 4979.953 | 26630.920 | 8148.477 | 0.000 | 0.000 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 28469.084 | 0.000 | 0.000 | 0.000 |
December | 0.118930E+12 | 70374.171 | 03-DEC-18:45 | 4979.953 | 26630.920 | 8148.477 | 0.000 | 0.000 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 28061.820 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.144089E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||
Minimum of Months | 0.108938E+12 | 70374.171 | 4979.953 | 26630.920 | 8148.477 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 21200.695 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.133089E+12 | 82841.806 | 4979.953 | 26630.920 | 8148.477 | 0.000 | 19409.899 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32381.806 | 0.000 | 0.000 | 0.000 |
Report: PEAK GAS DEMAND
For: Meter
Timestamp: 2015-09-09 18:47:55
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC {AT MAX/MIN} [W] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT [Invalid/Undefined] | WATERSYSTEMS:GAS [Invalid/Undefined] | WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.980085E+11 | 99540.547 | 15-JAN-05:00 | 99540.547 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 99540.547 |
February | 0.733409E+11 | 93128.989 | 23-FEB-07:30 | 93128.989 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 93128.989 |
March | 0.459315E+11 | 59388.776 | 11-MAR-08:00 | 59388.776 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 59388.776 |
April | 0.224466E+11 | 79985.126 | 13-APR-06:15 | 79985.126 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 79985.126 |
May | 0.451256E+10 | 17472.001 | 10-MAY-02:15 | 17472.001 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17472.001 |
June | 5062108.382 | 1226.960 | 23-JUN-04:30 | 1226.960 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 1226.960 |
July | 0.000 | 0.000 | 01-JUL-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 891980.501 | 112.204 | 18-AUG-03:00 | 112.204 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 112.204 |
September | 0.445743E+09 | 4443.430 | 28-SEP-05:00 | 4443.430 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4443.430 |
October | 0.156876E+11 | 34643.666 | 05-OCT-02:00 | 34643.666 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 34643.666 |
November | 0.530489E+11 | 65406.307 | 30-NOV-21:15 | 65406.307 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 65406.307 |
December | 0.105149E+12 | 104817.133 | 25-DEC-08:00 | 104817.133 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 104817.133 |
Annual Sum or Average | 0.418577E+12 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | ||||
Minimum of Months | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.105149E+12 | 104817.133 | 104817.133 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 104817.133 |