Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:47

Tabular Output Report in Format: HTML

Building: Mid-Rise Apartment

Environment: Burlington International Ap VT USA TMY3 WMO#=726170

Simulation Timestamp: 2015-09-09 18:47:29


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:29

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 2060.40 657.31 729.61
Net Site Energy 2060.40 657.31 729.61
Total Source Energy 5145.14 1641.39 1821.95
Net Source Energy 5145.14 1641.39 1821.95


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 3134.61
Net Conditioned Building Area 2823.98
Unconditioned Building Area 310.64


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 0.00 662.58 0.00 0.00 0.00 0.00
Cooling 76.53 0.00 0.00 0.00 0.00 0.00
Interior Lighting 118.46 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 40.08 0.00 0.00 0.00 0.00 0.00
Interior Equipment 517.65 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 213.20 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 431.90 0.00 0.00 0.00 0.00 1874.72
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 1397.82 662.58 0.00 0.00 0.00 1874.72
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating General 0.00 662.58 0.00 0.00 0.00 0.00
Cooling General 76.53 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 96.36 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 22.11 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 40.08 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 517.65 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 213.20 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 431.90 0.00 0.00 0.00 0.00 1874.72
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 56.14 0.00 0.00 0.00 0.00 0.00
HVAC 255.54 234.63 0.00 0.00 0.00 0.66
Other 183.31 0.00 0.00 0.00 0.00 0.00
Total 494.98 234.63 0.00 0.00 0.00 0.66


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 50.58 0.00 0.00 0.00 0.00 0.00
HVAC 230.21 211.37 0.00 0.00 0.00 0.60
Other 165.14 0.00 0.00 0.00 0.00 0.00
Total 445.93 211.37 0.00 0.00 0.00 0.60


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 1397.82 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 1397.82 100.00
     
Total On-Site and Utility Electric Sources 1397.82 100.00
Total Electricity End Uses 1397.82 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 1874.72 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 1874.72 100.00
Total Water End Uses 1874.72 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 41.50
Time Setpoint Not Met During Occupied Cooling 4.75
Time Not Comfortable Based on Simple ASHRAE 55-2004 3528.00


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |

PEAK ELECTRICAL DEMAND

| Meter |

PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:29

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:47
RunPeriod Burlington International Ap VT USA TMY3 WMO#=726170
Weather File Burlington International Ap VT USA TMY3 WMO#=726170
Latitude [deg] 44.47
Longitude [deg] -73.2
Elevation [m] 101.00
Time Zone -5.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1542.04 564.80 206.22 564.80 206.22
Window Opening Area [m2] 306.92 112.97 37.16 112.97 43.82
Window-Wall Ratio [%] 19.90 20.00 18.02 20.00 21.25


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1501.17 564.80 185.79 564.80 185.79
Window Opening Area [m2] 300.26 112.97 37.16 112.97 37.16
Window-Wall Ratio [%] 20.00 20.00 20.00 20.00 20.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
OFFICE 88.25 Yes Yes 268.97 1.00 58.52 11.71 26.1977 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
M SW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 3.6746 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 3.6746 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 3.6746 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 3.6746 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 3.6746 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 3.6746 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 3.6746 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 3.6746 35.30 6.6700
T SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 1.11 5.9540   0.0000
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 3.32 5.9540   208.8202
M CORRIDOR 77.66 No Yes 236.69 2.00 10.22 1.11 5.9540   0.0000
Total 3134.61     9553.84   1542.04 306.92 4.5346 39.93 11.1825
Conditioned Total 2823.98     8607.06   1501.17 300.26 4.3785 35.97 6.6700
Unconditioned Total 310.64     946.78   40.87 6.66 5.9540   52.2051
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:29

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 20-JUL-17:00 27-JAN-06:00 - - - 01-JAN-07:15
Heating 0.00 133750.90 0.00 0.00 0.00 0.00
Cooling 25971.63 0.00 0.00 0.00 0.00 0.00
Interior Lighting 4979.95 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 26630.92 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 6760.37 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 23590.14 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 87933.02 133750.90 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating General 0.00 133750.90 0.00 0.00 0.00 0.00
Cooling General 25971.63 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 4056.31 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 923.64 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 26630.92 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 6760.37 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 23590.14 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:29

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 0.00 718.24 0.00 0.00 0.00
Cooling 242.38 0.00 0.00 0.00 0.00
Interior Lighting 375.17 0.00 0.00 0.00 0.00
Exterior Lighting 126.92 0.00 0.00 0.00 0.00
Interior Equipment 1639.40 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 675.19 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 1367.83 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 4426.90 718.24 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 254.33 0.00 0.00 0.00
Cooling 85.83 0.00 0.00 0.00 0.00
Interior Lighting 132.85 0.00 0.00 0.00 0.00
Exterior Lighting 44.94 0.00 0.00 0.00 0.00
Interior Equipment 580.53 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 239.09 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 484.36 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1567.61 254.33 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 254.33 0.00 0.00 0.00
Cooling 85.83 0.00 0.00 0.00 0.00
Interior Lighting 132.85 0.00 0.00 0.00 0.00
Exterior Lighting 44.94 0.00 0.00 0.00 0.00
Interior Equipment 580.53 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 239.09 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 484.36 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1567.61 254.33 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:29

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB -22.40 0.00 -22.40 Wetbulb [C] 3.00 60.00
BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 31.30 10.70 21.70 Wetbulb [C] 4.50 170.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:29

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
M WWALL SWA RES_EXT_WALL 0.30 0.324 0.340 46.45 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.324 0.340 70.60 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.324 0.340 70.60 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.324 0.340 46.45 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.324 0.340 46.45 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.324 0.340 70.60 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.324 0.340 70.60 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.324 0.340 46.45 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.324 0.340 70.60 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.324 0.340 70.60 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.324 0.340 70.60 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.324 0.340 70.60 180.00 90.00 S
T WWALL SWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.324 0.340 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.324 0.340 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.324 0.340 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.324 0.340 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.30 0.269 0.283 77.66 180.00 0.00  
G WWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.324 0.340 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 90.00 180.00  
M WWALL C RES_EXT_WALL 0.30 0.324 0.340 10.22 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.324 0.340 10.22 90.00 90.00 E


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW1 S SWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL SWA 180.00 90.00 S
GWINDOW1 W SWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G WWALL SWA 270.00 90.00 W
GWINDOW1 N NWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL NWA 0.00 90.00 N
GWINDOW1 W NWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G WWALL NWA 270.00 90.00 W
GWINDOW1 S SEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL SEA 180.00 90.00 S
GWINDOW1 E SEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G EWALL SEA 90.00 90.00 E
GWINDOW1 N NEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL NEA 0.00 90.00 N
GWINDOW1 E NEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G EWALL NEA 90.00 90.00 E
GWINDOW1 N N1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL N1A 0.00 90.00 N
GWINDOW1 N N2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL N2A 0.00 90.00 N
GWINDOW1 S S1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL S1A 180.00 90.00 S
GWINDOW1 S S2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL S2A 180.00 90.00 S
MWINDOW1 W SWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M WWALL SWA 270.00 90.00 W
MWINDOW1 S SWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL SWA 180.00 90.00 S
MWINDOW1 N NWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL NWA 0.00 90.00 N
MWINDOW1 W NWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M WWALL NWA 270.00 90.00 W
MWINDOW1 E SEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M EWALL SEA 90.00 90.00 E
MWINDOW1 S SEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL SEA 180.00 90.00 S
MWINDOW1 N NEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL NEA 0.00 90.00 N
MWINDOW1 E NEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M EWALL NEA 90.00 90.00 E
MWINDOW1 N N1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL N1A 0.00 90.00 N
MWINDOW1 N N2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL N2A 0.00 90.00 N
MWINDOW1 S S1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL S1A 180.00 90.00 S
MWINDOW1 S S2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL S2A 180.00 90.00 S
TWINDOW1 W SWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T WWALL SWA 270.00 90.00 W
TWINDOW1 S SWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL SWA 180.00 90.00 S
TWINDOW1 N NWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL NWA 0.00 90.00 N
TWINDOW1 W NWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T WWALL NWA 270.00 90.00 W
TWINDOW1 E SEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T EWALL SEA 90.00 90.00 E
TWINDOW1 S SEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL SEA 180.00 90.00 S
TWINDOW1 N NEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL NEA 0.00 90.00 N
TWINDOW1 E NEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T EWALL NEA 90.00 90.00 E
TWINDOW1 N N1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL N1A 0.00 90.00 N
TWINDOW1 N N2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL N2A 0.00 90.00 N
TWINDOW1 S S1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL S1A 180.00 90.00 S
TWINDOW1 S S2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL S2A 180.00 90.00 S
TWINDOW14 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No T EWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.52_SHGC_0.40 3.32 0.00 0.00 3.32 3.32 2.653 0.426 0.308     No G EWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 2.23 2.653 0.426 0.308     No M EWALL C 270.00 90.00 W
Total or Average           306.92 2.653 0.426 0.308              
North Total or Average           112.97 2.653 0.426 0.308              
Non-North Total or Average           193.95 2.653 0.426 0.308              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:29

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 W SWA 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
GWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 W NWA 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
GWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 E SEA 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
GWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 E NEA 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
GWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 W SWA 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
MWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 W NWA 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
MWINDOW1 E SEA 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
MWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 E NEA 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
MWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 W SWA 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
TWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 W NWA 0.00 0.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00
TWINDOW1 E SEA 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
TWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 E NEA 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
TWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
MWINDOW14 1.00 1.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:29

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
LIGHTING_HARDWIRED_GSW G SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GNW G NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_OFFICE OFFICE 13.0989 88.25 1155.96 GeneralLights LTG_OFF_SCH 62.17 168.00 60.95 0.0000 Y 13.23
LIGHTING_HARDWIRED_GNE G NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GN1 G N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GN2 G N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GS1 G S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GS2 G S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MSW M SW APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MNW M NW APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MSE M SE APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MNE M NE APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MN1 M N1 APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MN2 M N2 APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MS1 M S1 APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MS2 M S2 APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TSW T SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TNW T NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TSE T SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TNE T NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TN1 T N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TN2 T N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TS1 T S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TS2 T S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GC G CORRIDOR 5.9540 77.66 462.39 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 14.58
LIGHTING_HARDWIRED_MC M CORRIDOR 5.9540 155.32 924.77 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 14.58
LIGHTING_HARDWIRED_TC T CORRIDOR 5.9540 77.66 462.39 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 14.58
LIGHTING_PLUGIN_GSW G SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_GNW G NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_OFFICE OFFICE 13.0989 88.25 1155.96 GeneralLights-plugin LTG_OFF_SCH 62.17 168.00 60.95 0.0000 Y 13.23
LIGHTING_PLUGIN_GNE G NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_GN1 G N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_GN2 G N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_GS1 G S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_GS2 G S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MSW M SW APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MNW M NW APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MSE M SE APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MNE M NE APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MN1 M N1 APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MN2 M N2 APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MS1 M S1 APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MS2 M S2 APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TSW T SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TNW T NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TSE T SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TNE T NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TN1 T N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TN2 T N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TS1 T S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TS2 T S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
Interior Lighting Total   2.3855 5958.59 14214.30               95.19


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 2553.00 AstronomicalClock -   83.63 83.63 40.08
Exterior Lighting Total 2553.00           40.08



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:29

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
None          


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
SPLIT GSW COOLING COIL Coil:Cooling:DX:SingleSpeed   3028.38 2249.93 778.45 0.74 3.91    
SPLIT GNW COOLING COIL Coil:Cooling:DX:SingleSpeed   2802.54 2088.19 714.35 0.75 3.91    
SPLIT OFFICE COOLING COIL Coil:Cooling:DX:SingleSpeed   7733.97 6176.78 1557.19 0.80 3.91    
SPLIT GNE COOLING COIL Coil:Cooling:DX:SingleSpeed   2101.91 1531.19 570.72 0.73 3.91    
SPLIT GN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   1720.68 1236.84 483.84 0.72 3.91    
SPLIT GN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   1704.02 1223.42 480.60 0.72 3.91    
SPLIT GS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   2170.39 1559.46 610.93 0.72 3.91    
SPLIT GS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   2216.37 1598.54 617.83 0.72 3.91    
SPLIT MSW COOLING COIL Coil:Cooling:DX:SingleSpeed   8180.55 6218.11 1962.44 0.76 3.91    
SPLIT MNW COOLING COIL Coil:Cooling:DX:SingleSpeed   7602.89 5769.12 1833.77 0.76 3.91    
SPLIT MSE COOLING COIL Coil:Cooling:DX:SingleSpeed   7707.98 5780.76 1927.22 0.75 3.91    
SPLIT MNE COOLING COIL Coil:Cooling:DX:SingleSpeed   6045.70 4534.82 1510.89 0.75 3.91    
SPLIT MN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   4842.64 3593.24 1249.40 0.74 3.91    
SPLIT MN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   4814.15 3570.00 1244.14 0.74 3.91    
SPLIT MS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   6024.82 4462.93 1561.89 0.74 3.91    
SPLIT MS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   6042.44 4477.36 1565.08 0.74 3.91    
SPLIT TSW COOLING COIL Coil:Cooling:DX:SingleSpeed   5554.63 4252.11 1302.52 0.77 3.91    
SPLIT TNW COOLING COIL Coil:Cooling:DX:SingleSpeed   4986.66 3809.79 1176.87 0.76 3.91    
SPLIT TSE COOLING COIL Coil:Cooling:DX:SingleSpeed   5210.40 3969.18 1241.22 0.76 3.91    
SPLIT TNE COOLING COIL Coil:Cooling:DX:SingleSpeed   4260.45 3189.23 1071.22 0.75 3.91    
SPLIT TN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   3417.11 2541.99 875.12 0.74 3.91    
SPLIT TN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   3418.88 2543.31 875.56 0.74 3.91    
SPLIT TS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   4330.78 3289.83 1040.95 0.76 3.91    
SPLIT TS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   4342.08 3299.12 1042.96 0.76 3.91    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
SPLIT GSW COOLING COIL Coil:Cooling:DX:SingleSpeed 2906.4 3.23 11.01 11.45 10.87
SPLIT GNW COOLING COIL Coil:Cooling:DX:SingleSpeed 2688.9 3.22 10.99 11.44 10.85
SPLIT OFFICE COOLING COIL Coil:Cooling:DX:SingleSpeed 7367.8 3.13 10.67 11.09 10.38
SPLIT GNE COOLING COIL Coil:Cooling:DX:SingleSpeed 2021.1 3.25 11.10 11.55 11.00
SPLIT GN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 1656.7 3.27 11.16 11.62 11.09
SPLIT GN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 1640.8 3.27 11.16 11.62 11.10
SPLIT GS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 2089.7 3.27 11.16 11.62 11.09
SPLIT GS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 2133.2 3.27 11.14 11.60 11.07
SPLIT MSW COOLING COIL Coil:Cooling:DX:SingleSpeed 7833.3 3.19 10.90 11.34 10.71
SPLIT MNW COOLING COIL Coil:Cooling:DX:SingleSpeed 7281.4 3.20 10.91 11.35 10.72
SPLIT MSE COOLING COIL Coil:Cooling:DX:SingleSpeed 7390.7 3.21 10.96 11.41 10.80
SPLIT MNE COOLING COIL Coil:Cooling:DX:SingleSpeed 5796.8 3.21 10.96 11.40 10.80
SPLIT MN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 4648.2 3.23 11.01 11.46 10.87
SPLIT MN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 4621.2 3.23 11.01 11.46 10.88
SPLIT MS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 5783.9 3.23 11.02 11.47 10.89
SPLIT MS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 5800.7 3.23 11.02 11.47 10.88
SPLIT TSW COOLING COIL Coil:Cooling:DX:SingleSpeed 5315.1 3.19 10.87 11.30 10.66
SPLIT TNW COOLING COIL Coil:Cooling:DX:SingleSpeed 4772.5 3.19 10.88 11.31 10.68
SPLIT TSE COOLING COIL Coil:Cooling:DX:SingleSpeed 4988.1 3.19 10.89 11.33 10.70
SPLIT TNE COOLING COIL Coil:Cooling:DX:SingleSpeed 4085.9 3.22 10.97 11.41 10.81
SPLIT TN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 3279.1 3.22 11.00 11.45 10.86
SPLIT TN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 3280.8 3.22 11.00 11.45 10.86
SPLIT TS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 4147.2 3.20 10.90 11.34 10.72
SPLIT TS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 4158.0 3.20 10.90 11.34 10.71
ANSI/AHRI ratings include supply fan

DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
SPLIT GSW HEATING COIL Coil:Heating:Gas   3969.55 0.80
SPLIT GNW HEATING COIL Coil:Heating:Gas   3939.34 0.80
SPLIT OFFICE HEATING COIL Coil:Heating:Gas   6758.44 0.80
SPLIT GNE HEATING COIL Coil:Heating:Gas   3949.77 0.80
SPLIT GN1 HEATING COIL Coil:Heating:Gas   3038.82 0.80
SPLIT GN2 HEATING COIL Coil:Heating:Gas   3039.06 0.80
SPLIT GS1 HEATING COIL Coil:Heating:Gas   3022.61 0.80
SPLIT GS2 HEATING COIL Coil:Heating:Gas   3157.36 0.80
SPLIT MSW HEATING COIL Coil:Heating:Gas   7653.02 0.80
SPLIT MNW HEATING COIL Coil:Heating:Gas   7697.97 0.80
SPLIT MSE HEATING COIL Coil:Heating:Gas   7680.34 0.80
SPLIT MNE HEATING COIL Coil:Heating:Gas   7725.31 0.80
SPLIT MN1 HEATING COIL Coil:Heating:Gas   5436.16 0.80
SPLIT MN2 HEATING COIL Coil:Heating:Gas   5436.81 0.80
SPLIT MS1 HEATING COIL Coil:Heating:Gas   5393.69 0.80
SPLIT MS2 HEATING COIL Coil:Heating:Gas   5394.34 0.80
SPLIT TSW HEATING COIL Coil:Heating:Gas   5631.73 0.80
SPLIT TNW HEATING COIL Coil:Heating:Gas   5657.45 0.80
SPLIT TSE HEATING COIL Coil:Heating:Gas   5646.20 0.80
SPLIT TNE HEATING COIL Coil:Heating:Gas   5671.92 0.80
SPLIT TN1 HEATING COIL Coil:Heating:Gas   4418.61 0.80
SPLIT TN2 HEATING COIL Coil:Heating:Gas   4418.97 0.80
SPLIT TS1 HEATING COIL Coil:Heating:Gas   4391.11 0.80
SPLIT TS2 HEATING COIL Coil:Heating:Gas   4391.48 0.80


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
SPLIT GSW SUPPLY FAN Fan:OnOff 0.54 622.50 0.16 180.19 1160.84 1.00 General
SPLIT GNW SUPPLY FAN Fan:OnOff 0.54 622.50 0.14 167.91 1160.84 1.00 General
SPLIT OFFICE SUPPLY FAN Fan:OnOff 0.54 622.50 0.47 542.35 1160.84 1.00 General
SPLIT GNE SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 119.26 1160.84 1.00 General
SPLIT GN1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.08 94.46 1160.84 1.00 General
SPLIT GN2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.08 93.27 1160.84 1.00 General
SPLIT GS1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.10 119.03 1160.84 1.00 General
SPLIT GS2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.11 122.70 1160.84 1.00 General
SPLIT MSW SUPPLY FAN Fan:OnOff 0.54 622.50 0.44 513.53 1160.84 1.00 General
SPLIT MNW SUPPLY FAN Fan:OnOff 0.54 622.50 0.41 475.38 1160.84 1.00 General
SPLIT MSE SUPPLY FAN Fan:OnOff 0.54 622.50 0.40 468.95 1160.84 1.00 General
SPLIT MNE SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 367.96 1160.84 1.00 General
SPLIT MN1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 287.27 1160.84 1.00 General
SPLIT MN2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.25 285.18 1160.84 1.00 General
SPLIT MS1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 355.96 1160.84 1.00 General
SPLIT MS2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 357.27 1160.84 1.00 General
SPLIT TSW SUPPLY FAN Fan:OnOff 0.54 622.50 0.31 354.41 1160.84 1.00 General
SPLIT TNW SUPPLY FAN Fan:OnOff 0.54 622.50 0.27 316.73 1160.84 1.00 General
SPLIT TSE SUPPLY FAN Fan:OnOff 0.54 622.50 0.28 328.74 1160.84 1.00 General
SPLIT TNE SUPPLY FAN Fan:OnOff 0.54 622.50 0.22 258.07 1160.84 1.00 General
SPLIT TN1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 203.94 1160.84 1.00 General
SPLIT TN2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.18 204.05 1160.84 1.00 General
SPLIT TS1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 271.47 1160.84 1.00 General
SPLIT TS2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.23 272.32 1160.84 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
None              


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
G SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M SE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T SE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:29

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1632.20 1958.64 0.129 0.155 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 16:45:00 30.02 0.01255
G NW APARTMENT 1520.99 1825.19 0.121 0.145 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 28.73 0.01255
OFFICE 4810.79 5772.95 0.389 0.467 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 09:00:00 25.41 0.01255
G NE APARTMENT 1080.26 1296.32 0.086 0.103 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 27.64 0.01255
G N1 APARTMENT 855.68 1026.82 0.068 0.081 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
G N2 APARTMENT 844.89 1013.87 0.067 0.080 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
G S1 APARTMENT 1078.18 1293.81 0.085 0.103 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
G S2 APARTMENT 1111.47 1333.76 0.088 0.106 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:15:00 30.90 0.01255
M SW APARTMENT 4651.61 5581.93 0.369 0.442 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 29.53 0.01255
M NW APARTMENT 4306.15 5167.38 0.341 0.410 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 28.73 0.01255
M SE APARTMENT 4247.76 5097.32 0.337 0.404 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:15:00 30.90 0.01255
M NE APARTMENT 3332.90 3999.49 0.264 0.317 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 10:15:00 27.64 0.01255
M N1 APARTMENT 2602.23 3122.68 0.206 0.247 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
M N2 APARTMENT 2583.31 3099.97 0.205 0.246 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 18:45:00 27.53 0.01255
M S1 APARTMENT 3224.44 3869.33 0.256 0.307 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
M S2 APARTMENT 3236.25 3883.50 0.256 0.308 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
T SW APARTMENT 3210.04 3852.05 0.254 0.305 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 15:30:00 30.98 0.01255
T NW APARTMENT 2868.79 3442.55 0.227 0.273 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 16:45:00 30.02 0.01255
T SE APARTMENT 2977.56 3573.07 0.236 0.283 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:30:00 31.03 0.01255
T NE APARTMENT 2337.44 2804.92 0.185 0.222 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 31.30 0.01255
T N1 APARTMENT 1847.31 2216.78 0.146 0.176 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 14:45:00 31.30 0.01255
T N2 APARTMENT 1848.28 2217.94 0.146 0.176 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 31.30 0.01255
T S1 APARTMENT 2459.01 2950.81 0.195 0.234 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 31.17 0.01255
T S2 APARTMENT 2466.65 2959.98 0.195 0.235 BURLINGTON INTERNATIONAL AP ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 31.17 0.01255


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 2157.40 2588.88 0.063 0.075 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -22.40 0.00051
G NW APARTMENT 2174.01 2608.82 0.063 0.076 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -22.40 0.00051
OFFICE 4066.11 4879.33 0.115 0.138 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -22.40 0.00051
G NE APARTMENT 2182.83 2619.39 0.064 0.076 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -22.40 0.00051
G N1 APARTMENT 1412.48 1694.97 0.041 0.049 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -22.40 0.00051
G N2 APARTMENT 1412.68 1695.21 0.041 0.049 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -22.40 0.00051
G S1 APARTMENT 1398.76 1678.52 0.041 0.049 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -22.40 0.00051
G S2 APARTMENT 1512.72 1815.26 0.044 0.053 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 09:00:00 -22.40 0.00051
M SW APARTMENT 4157.35 4988.82 0.121 0.145 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -22.40 0.00051
M NW APARTMENT 4195.37 5034.44 0.122 0.147 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -22.40 0.00051
M SE APARTMENT 4180.46 5016.55 0.122 0.146 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -22.40 0.00051
M NE APARTMENT 4218.49 5062.18 0.123 0.147 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -22.40 0.00051
M N1 APARTMENT 2282.57 2739.09 0.066 0.080 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -22.40 0.00051
M N2 APARTMENT 2283.13 2739.76 0.066 0.080 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -22.40 0.00051
M S1 APARTMENT 2246.66 2696.00 0.065 0.079 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -22.40 0.00051
M S2 APARTMENT 2247.22 2696.66 0.065 0.079 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -22.40 0.00051
T SW APARTMENT 3605.30 4326.36 0.105 0.126 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -22.40 0.00051
T NW APARTMENT 3627.05 4352.46 0.106 0.127 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -22.40 0.00051
T SE APARTMENT 3617.54 4341.05 0.105 0.126 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -22.40 0.00051
T NE APARTMENT 3639.29 4367.15 0.106 0.127 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -22.40 0.00051
T N1 APARTMENT 2579.37 3095.24 0.075 0.090 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -22.40 0.00051
T N2 APARTMENT 2579.68 3095.61 0.075 0.090 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -22.40 0.00051
T S1 APARTMENT 2556.12 3067.34 0.074 0.089 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -22.40 0.00051
T S2 APARTMENT 2556.43 3067.71 0.074 0.089 BURLINGTON INTERNATIONAL AP ANN HTG 99.6% CONDNS DB 1/21 04:00:00 -22.40 0.00051


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
SPLIT GSW 0.16 0.16 0.08 0.08
SPLIT GNW 0.14 0.14 0.08 0.08
SPLIT OFFICE 0.47 0.47 0.14 0.14
SPLIT GNE 0.10 0.10 0.08 0.08
SPLIT GN1 0.08 0.08 0.05 0.05
SPLIT GN2 0.08 0.08 0.05 0.05
SPLIT GS1 0.10 0.10 0.05 0.05
SPLIT GS2 0.11 0.11 0.05 0.05
SPLIT MSW 0.44 0.44 0.15 0.15
SPLIT MNW 0.41 0.41 0.15 0.15
SPLIT MSE 0.40 0.40 0.15 0.15
SPLIT MNE 0.32 0.32 0.15 0.15
SPLIT MN1 0.25 0.25 0.08 0.08
SPLIT MN2 0.25 0.25 0.08 0.08
SPLIT MS1 0.31 0.31 0.08 0.08
SPLIT MS2 0.31 0.31 0.08 0.08
SPLIT TSW 0.31 0.31 0.13 0.13
SPLIT TNW 0.27 0.27 0.13 0.13
SPLIT TSE 0.28 0.28 0.13 0.13
SPLIT TNE 0.22 0.22 0.13 0.13
SPLIT TN1 0.18 0.18 0.09 0.09
SPLIT TN2 0.18 0.18 0.09 0.09
SPLIT TS1 0.23 0.23 0.09 0.09
SPLIT TS2 0.23 0.23 0.09 0.09



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:29

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 3848.00 6682.25 2445.75
G NW APARTMENT 4222.50 6870.50 2988.75
OFFICE 792.75 1551.75 418.00
G NE APARTMENT 4208.50 6900.75 2991.00
G N1 APARTMENT 3588.00 7024.25 2587.75
G N2 APARTMENT 3589.00 7021.00 2588.00
G S1 APARTMENT 3062.75 6697.50 1818.00
G S2 APARTMENT 3323.75 6620.00 2002.25
M SW APARTMENT 3215.00 5118.25 750.75
M NW APARTMENT 3686.75 5546.50 1401.25
M SE APARTMENT 3221.00 5128.75 725.50
M NE APARTMENT 3668.00 5577.75 1396.00
M N1 APARTMENT 2863.00 5478.25 686.00
M N2 APARTMENT 2862.50 5480.50 685.00
M S1 APARTMENT 2639.25 4896.00 212.75
M S2 APARTMENT 2637.25 4897.50 214.00
T SW APARTMENT 4778.25 5814.00 2585.25
T NW APARTMENT 5118.75 6104.25 3097.50
T SE APARTMENT 4800.50 5809.50 2574.00
T NE APARTMENT 5118.00 6098.25 3091.75
T N1 APARTMENT 4730.25 6098.00 2758.75
T N2 APARTMENT 4727.50 6095.00 2758.25
T S1 APARTMENT 4344.50 5718.25 2168.50
T S2 APARTMENT 4348.50 5716.50 2170.50
T CORRIDOR 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
Facility 5968.00 7094.00 3528.00
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 3.00 3.00 3.00 3.00
G NW APARTMENT 3.25 2.50 3.25 2.50
OFFICE 17.50 6.75 0.50 0.00
G NE APARTMENT 6.50 4.75 6.50 4.75
G N1 APARTMENT 3.50 3.50 3.50 3.50
G N2 APARTMENT 3.50 3.75 3.50 3.75
G S1 APARTMENT 1.50 0.00 1.50 0.00
G S2 APARTMENT 1.25 0.00 1.25 0.00
M SW APARTMENT 2.50 2.25 2.50 2.25
M NW APARTMENT 1.25 2.00 1.25 2.00
M SE APARTMENT 2.50 0.00 2.50 0.00
M NE APARTMENT 1.50 3.75 1.50 3.75
M N1 APARTMENT 0.50 2.75 0.50 2.75
M N2 APARTMENT 1.00 2.75 1.00 2.75
M S1 APARTMENT 2.00 0.00 2.00 0.00
M S2 APARTMENT 1.25 0.00 1.25 0.00
T SW APARTMENT 0.25 0.75 0.25 0.75
T NW APARTMENT 0.00 2.50 0.00 2.50
T SE APARTMENT 1.00 0.00 1.00 0.00
T NE APARTMENT 0.75 3.25 0.75 3.25
T N1 APARTMENT 2.25 3.25 2.25 3.25
T N2 APARTMENT 2.50 3.00 2.50 3.00
T S1 APARTMENT 2.00 0.00 2.00 0.00
T S2 APARTMENT 3.00 0.00 3.00 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
Facility 58.50 11.50 41.50 4.75
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:29

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.97 0.366 0.192 0.000 0.076
G NW APARTMENT 1.71 2.50 268.97 0.353 0.192 0.000 0.067
OFFICE 0.94 1.00 268.97 0.519 0.219 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.353 0.192 0.000 0.067
G N1 APARTMENT 1.71 2.50 268.97 0.353 0.116 0.000 0.066
G N2 APARTMENT 1.71 2.50 268.97 0.353 0.116 0.000 0.066
G S1 APARTMENT 1.71 2.50 268.97 0.353 0.116 0.000 0.076
G S2 APARTMENT 1.71 2.50 268.97 0.353 0.116 0.000 0.076
M SW APARTMENT 1.71 2.50 268.97 0.353 0.276 0.000 0.095
M NW APARTMENT 1.71 2.50 268.97 0.353 0.276 0.000 0.081
M SE APARTMENT 1.71 2.50 268.97 0.353 0.276 0.000 0.095
M NE APARTMENT 1.71 2.50 268.97 0.353 0.276 0.000 0.081
M N1 APARTMENT 1.71 2.50 268.97 0.353 0.167 0.000 0.081
M N2 APARTMENT 1.71 2.50 268.97 0.353 0.167 0.000 0.081
M S1 APARTMENT 1.71 2.50 268.97 0.353 0.167 0.000 0.095
M S2 APARTMENT 1.71 2.50 268.97 0.353 0.167 0.000 0.095
T SW APARTMENT 1.71 2.50 268.97 0.353 0.365 0.000 0.114
T NW APARTMENT 1.71 2.50 268.97 0.353 0.365 0.000 0.095
T SE APARTMENT 1.71 2.50 268.97 0.353 0.365 0.000 0.114
T NE APARTMENT 1.71 2.50 268.97 0.353 0.365 0.000 0.095
T N1 APARTMENT 1.71 2.50 268.97 0.353 0.220 0.000 0.095
T N2 APARTMENT 1.71 2.50 268.97 0.353 0.220 0.000 0.095
T S1 APARTMENT 1.71 2.50 268.97 0.353 0.220 0.000 0.114
T S2 APARTMENT 1.71 2.50 268.97 0.353 0.220 0.000 0.114
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.97 0.353 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.97 0.340 0.000 0.000 0.000
OFFICE 0.94 1.00 268.97 0.499 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.340 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.97 0.340 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.340 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.97 0.340 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.340 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.97 1.361 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.97 1.361 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.97 1.361 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.97 1.361 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.97 1.361 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 1.361 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.97 1.361 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 1.361 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.97 0.340 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.97 0.340 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.97 0.340 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.97 0.340 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.97 0.340 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.340 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.97 0.340 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.340 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:29

Surfaces by Class

Total Outdoors
Wall 126 42
Floor 27 9
Roof 27 9
Internal Mass 24 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 39 39
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 24
Conditioned Zones 24
Unconditioned Zones 3
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 1385
Defaulted Fields 439
Fields with Defaults 3704
Autosized Fields 336
Autosizable Fields 454
Autocalculated Fields 247
Autocalculatable Fields 424



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2015-09-09 18:47:29

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 1397.82 19872.99 01-JAN-03:15 87933.02 20-JUL-18:00
Electricity:Building 636.11 10559.61 01-JAN-03:15 31610.87 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity 118.46 2466.75 01-JAN-00:15 5482.59 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 96.36 2205.67 01-JAN-00:15 4426.44 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:OFFICE 35.93 610.39 01-JAN-00:15 2669.36 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 26.45 416.15 01-JAN-00:15 2080.74 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M SW APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:T SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G CORRIDOR 144.16 1427.03 01-JAN-00:15 8651.76 01-JAN-07:15
InteriorLights:Electricity:Zone:G CORRIDOR 14.58 462.39 01-JAN-00:15 462.39 01-JAN-00:15
Electricity:Zone:M CORRIDOR 29.16 924.77 01-JAN-00:15 924.77 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 29.16 924.77 01-JAN-00:15 924.77 01-JAN-00:15
Electricity:Zone:T CORRIDOR 14.58 462.39 01-JAN-00:15 462.39 01-JAN-00:15
InteriorLights:Electricity:Zone:T CORRIDOR 14.58 462.39 01-JAN-00:15 462.39 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 22.11 261.08 01-JAN-00:15 1411.40 02-JAN-16:15
InteriorEquipment:Electricity 517.65 8092.87 01-JAN-03:15 26730.99 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 517.65 8092.87 01-JAN-03:15 26730.99 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 9.48 194.25 01-JAN-00:15 588.62 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G CORRIDOR 129.57 964.65 01-JAN-00:15 8189.37 01-JAN-07:15
Electricity:Plant 431.90 0.00 01-JAN-00:15 32852.25 21-FEB-08:00
WaterSystems:Electricity 431.90 0.00 01-JAN-00:15 32852.25 21-FEB-08:00
Water Heater:WaterSystems:Electricity 431.90 0.00 01-JAN-00:15 32852.25 21-FEB-08:00
Fans:Electricity 213.20 6760.37 02-JAN-18:15 6760.37 01-JAN-18:30
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 1397.82 19872.99 01-JAN-03:15 87933.02 20-JUL-18:00
ElectricityPurchased:Plant 1397.82 19872.99 01-JAN-03:15 87933.02 20-JUL-18:00
Cogeneration:ElectricityPurchased 1397.82 19872.99 01-JAN-03:15 87933.02 20-JUL-18:00
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 1397.82 19872.99 01-JAN-03:15 87933.02 20-JUL-18:00
ElectricityNet:Plant 1397.82 19872.99 01-JAN-03:15 87933.02 20-JUL-18:00
Cogeneration:ElectricityNet 1397.82 19872.99 01-JAN-03:15 87933.02 20-JUL-18:00
ExteriorLights:Electricity 40.08 0.00 01-JAN-07:45 2553.00 01-JAN-00:15
General:ExteriorLights:Electricity 40.08 0.00 01-JAN-07:45 2553.00 01-JAN-00:15
Electricity:HVAC 289.73 6760.37 02-JAN-18:15 35363.23 20-JUL-16:00
General:Fans:Electricity 213.20 6760.37 02-JAN-18:15 6760.37 01-JAN-18:30
Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:Electricity 76.53 0.00 01-JAN-00:15 28602.86 20-JUL-16:00


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 662.58 0.00 28-MAR-16:15 133750.90 27-JAN-07:00
Gas:HVAC 662.58 0.00 28-MAR-16:15 133750.90 27-JAN-07:00
Heating:Gas 662.58 0.00 28-MAR-16:15 133750.90 27-JAN-07:00


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
None          


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water:Plant 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
WaterSystems:Water 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
MainsWater:Facility 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
MainsWater:Plant 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
WaterSystems:MainsWater 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
PlantLoopHeatingDemand:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 1431.22 1561.80 14-OCT-14:00 175701.46 07-FEB-02:00
EnergyTransfer:Building 586.32 1438.33 08-OCT-13:30 72440.38 07-FEB-02:00
EnergyTransfer:Zone:G SW APARTMENT 15.52 0.00 20-APR-09:00 2277.07 07-FEB-02:00
Heating:EnergyTransfer 299.47 0.00 17-MAR-15:15 72293.54 07-FEB-02:00
Heating:EnergyTransfer:Zone:G SW APARTMENT 10.28 0.00 04-JAN-11:30 2277.07 07-FEB-02:00
Cooling:EnergyTransfer 286.85 0.00 02-JAN-07:15 66375.26 20-JUL-15:15
Cooling:EnergyTransfer:Zone:G SW APARTMENT 5.24 0.00 01-JAN-00:15 1813.02 20-JUL-14:30
EnergyTransfer:Zone:G NW APARTMENT 16.56 0.00 27-SEP-21:00 2389.13 07-FEB-02:00
Heating:EnergyTransfer:Zone:G NW APARTMENT 12.63 0.00 18-FEB-15:00 2389.13 07-FEB-02:00
Cooling:EnergyTransfer:Zone:G NW APARTMENT 3.93 0.00 01-JAN-00:15 1634.09 20-JUL-17:00
EnergyTransfer:Zone:OFFICE 21.41 0.02 30-OCT-04:00 4355.43 17-DEC-07:15
Heating:EnergyTransfer:Zone:OFFICE 2.33 0.00 01-JAN-00:15 4355.43 17-DEC-07:15
Cooling:EnergyTransfer:Zone:OFFICE 19.08 0.00 02-JAN-07:15 4350.06 06-AUG-11:00
EnergyTransfer:Zone:G NE APARTMENT 16.54 0.00 21-MAY-11:30 2369.73 07-FEB-02:00
Heating:EnergyTransfer:Zone:G NE APARTMENT 12.51 0.00 17-MAR-09:30 2369.73 07-FEB-02:00
Cooling:EnergyTransfer:Zone:G NE APARTMENT 4.02 0.00 01-JAN-00:15 1201.05 19-JUL-18:00
EnergyTransfer:Zone:G N1 APARTMENT 10.73 0.02 27-APR-13:00 1528.47 27-JAN-08:15
Heating:EnergyTransfer:Zone:G N1 APARTMENT 7.02 0.00 01-FEB-19:15 1528.47 27-JAN-08:15
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 3.71 0.00 01-JAN-00:15 927.33 19-JUL-18:45
EnergyTransfer:Zone:G N2 APARTMENT 10.73 0.00 31-OCT-18:30 1525.94 27-JAN-08:15
Heating:EnergyTransfer:Zone:G N2 APARTMENT 7.02 0.00 01-FEB-19:15 1525.94 27-JAN-08:15
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 3.71 0.00 01-JAN-00:15 916.84 19-JUL-18:45
EnergyTransfer:Zone:G S1 APARTMENT 10.19 0.04 22-APR-14:30 1349.06 07-FEB-02:00
Heating:EnergyTransfer:Zone:G S1 APARTMENT 5.04 0.00 01-JAN-11:15 1349.06 07-FEB-02:00
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 5.15 0.00 01-JAN-00:15 1263.00 02-SEP-12:30
EnergyTransfer:Zone:G S2 APARTMENT 10.98 0.06 13-MAY-15:00 1464.50 07-FEB-02:00
Heating:EnergyTransfer:Zone:G S2 APARTMENT 5.66 0.00 01-JAN-11:30 1464.50 07-FEB-02:00
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 5.32 0.00 01-JAN-00:15 1350.32 02-SEP-12:30
EnergyTransfer:Zone:M SW APARTMENT 39.20 0.06 31-MAY-05:45 5249.08 20-JUL-15:15
Heating:EnergyTransfer:Zone:M SW APARTMENT 15.78 0.00 01-JAN-11:15 4946.88 07-MAR-14:00
Cooling:EnergyTransfer:Zone:M SW APARTMENT 23.42 0.00 01-JAN-00:15 5249.08 20-JUL-15:15
EnergyTransfer:Zone:M NW APARTMENT 39.14 0.02 25-AUG-13:00 5402.39 07-MAR-14:00
Heating:EnergyTransfer:Zone:M NW APARTMENT 21.21 0.00 01-FEB-17:45 5402.39 07-MAR-14:00
Cooling:EnergyTransfer:Zone:M NW APARTMENT 17.93 0.00 01-JAN-00:15 4718.69 20-JUL-17:00
EnergyTransfer:Zone:M SE APARTMENT 39.31 0.08 08-OCT-20:30 4899.51 07-MAR-14:00
Heating:EnergyTransfer:Zone:M SE APARTMENT 15.72 0.00 01-JAN-11:00 4899.51 07-MAR-14:00
Cooling:EnergyTransfer:Zone:M SE APARTMENT 23.59 0.00 01-JAN-00:15 4813.06 20-JUL-14:15
EnergyTransfer:Zone:M NE APARTMENT 39.41 0.03 14-OCT-14:15 5348.63 07-MAR-14:00
Heating:EnergyTransfer:Zone:M NE APARTMENT 21.11 0.00 01-FEB-17:45 5348.63 07-MAR-14:00
Cooling:EnergyTransfer:Zone:M NE APARTMENT 18.30 0.00 01-JAN-00:15 3667.44 19-JUL-16:30
EnergyTransfer:Zone:M N1 APARTMENT 26.05 0.05 11-OCT-08:30 2935.15 07-MAR-14:00
Heating:EnergyTransfer:Zone:M N1 APARTMENT 8.31 0.00 09-JAN-16:45 2935.15 07-MAR-14:00
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 17.74 0.00 01-JAN-00:15 2850.82 19-JUL-17:30
EnergyTransfer:Zone:M N2 APARTMENT 26.04 0.16 01-OCT-16:00 2930.95 07-MAR-14:00
Heating:EnergyTransfer:Zone:M N2 APARTMENT 8.31 0.00 09-JAN-16:45 2930.95 07-MAR-14:00
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 17.73 0.00 01-JAN-00:15 2838.51 19-JUL-17:30
EnergyTransfer:Zone:M S1 APARTMENT 29.67 0.20 10-DEC-09:30 3701.24 02-SEP-12:30
Heating:EnergyTransfer:Zone:M S1 APARTMENT 4.94 0.00 01-JAN-09:15 2528.32 07-MAR-14:00
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 24.74 0.00 01-JAN-00:15 3701.24 02-SEP-12:30
EnergyTransfer:Zone:M S2 APARTMENT 29.67 0.07 10-NOV-04:00 3713.52 02-SEP-12:30
Heating:EnergyTransfer:Zone:M S2 APARTMENT 4.94 0.00 01-JAN-09:15 2525.08 07-MAR-14:00
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 24.73 0.00 01-JAN-00:15 3713.52 02-SEP-12:30
EnergyTransfer:Zone:T SW APARTMENT 29.72 0.00 20-MAY-01:00 4212.71 07-FEB-02:00
Heating:EnergyTransfer:Zone:T SW APARTMENT 19.77 0.00 04-JAN-11:00 4212.71 07-FEB-02:00
Cooling:EnergyTransfer:Zone:T SW APARTMENT 9.95 0.00 01-JAN-00:15 3749.09 20-JUL-15:15
EnergyTransfer:Zone:T NW APARTMENT 30.92 0.01 18-SEP-03:15 4344.48 07-FEB-02:00
Heating:EnergyTransfer:Zone:T NW APARTMENT 23.06 0.00 18-FEB-14:15 4344.48 07-FEB-02:00
Cooling:EnergyTransfer:Zone:T NW APARTMENT 7.87 0.00 01-JAN-00:15 3285.80 20-JUL-15:30
EnergyTransfer:Zone:T SE APARTMENT 29.47 0.02 15-MAY-15:45 4185.81 07-FEB-02:00
Heating:EnergyTransfer:Zone:T SE APARTMENT 19.61 0.00 04-JAN-10:45 4185.81 07-FEB-02:00
Cooling:EnergyTransfer:Zone:T SE APARTMENT 9.86 0.00 01-JAN-00:15 3407.82 20-JUL-14:15
EnergyTransfer:Zone:T NE APARTMENT 30.71 0.00 21-SEP-03:45 4320.14 07-FEB-02:00
Heating:EnergyTransfer:Zone:T NE APARTMENT 22.86 0.00 18-FEB-15:00 4320.14 07-FEB-02:00
Cooling:EnergyTransfer:Zone:T NE APARTMENT 7.85 0.00 01-JAN-00:15 2743.01 20-JUL-14:00
EnergyTransfer:Zone:T N1 APARTMENT 21.43 0.00 24-AUG-09:15 2868.98 07-FEB-02:00
Heating:EnergyTransfer:Zone:T N1 APARTMENT 14.31 0.00 01-FEB-19:45 2868.98 07-FEB-02:00
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 7.12 0.00 01-JAN-00:15 2130.53 20-JUL-14:00
EnergyTransfer:Zone:T N2 APARTMENT 21.43 0.01 12-MAY-11:15 2867.81 07-FEB-02:00
Heating:EnergyTransfer:Zone:T N2 APARTMENT 14.32 0.00 01-FEB-19:45 2867.81 07-FEB-02:00
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 7.11 0.00 01-JAN-00:15 2133.49 20-JUL-14:00
EnergyTransfer:Zone:T S1 APARTMENT 20.74 0.02 10-SEP-21:45 2790.02 20-JUL-14:15
Heating:EnergyTransfer:Zone:T S1 APARTMENT 11.37 0.00 01-JAN-11:30 2728.81 07-FEB-02:00
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 9.38 0.00 01-JAN-00:15 2790.02 20-JUL-14:15
EnergyTransfer:Zone:T S2 APARTMENT 20.75 0.02 04-OCT-00:15 2790.30 20-JUL-14:15
Heating:EnergyTransfer:Zone:T S2 APARTMENT 11.37 0.00 01-JAN-11:30 2727.25 07-FEB-02:00
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 9.38 0.00 01-JAN-00:15 2790.30 20-JUL-14:15
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:HVAC 844.90 0.00 28-MAR-16:15 107420.24 20-JUL-15:15
HeatingCoils:EnergyTransfer 530.06 0.00 28-MAR-16:15 107000.72 27-JAN-07:00
CoolingCoils:EnergyTransfer 314.83 0.00 01-JAN-00:15 107420.24 20-JUL-15:15



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:29

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 10.282 -5.242 0.000 0.000 3.895 1.087 12.213 11.249 0.000 0.104 0.000 0.000 -8.474 0.000 -9.085 -16.027
G NW APARTMENT 12.631 -3.927 0.000 0.000 3.907 1.087 12.213 5.822 0.000 0.099 0.000 0.000 -8.986 0.000 -8.938 -13.908
OFFICE 2.330 -19.080 0.000 0.000 0.535 26.452 9.482 11.055 0.000 0.052 0.002 0.000 -8.097 0.000 -7.979 -14.749
G NE APARTMENT 12.515 -4.022 0.000 0.000 3.915 1.087 12.213 5.716 0.000 0.099 0.000 0.000 -8.839 0.000 -8.922 -13.761
G N1 APARTMENT 7.018 -3.711 0.000 0.000 3.913 1.087 12.213 2.135 0.000 0.068 0.000 0.000 -5.651 0.000 -5.656 -11.415
G N2 APARTMENT 7.019 -3.715 0.000 0.000 3.914 1.087 12.213 2.134 0.000 0.068 0.000 0.000 -5.650 0.000 -5.656 -11.414
G S1 APARTMENT 5.040 -5.149 0.000 0.000 3.895 1.087 12.213 7.594 0.000 0.072 0.000 0.000 -5.139 0.000 -5.809 -13.804
G S2 APARTMENT 5.662 -5.320 0.000 0.000 3.892 1.087 12.213 7.591 0.000 0.072 0.000 0.000 -5.136 0.000 -5.819 -14.241
M SW APARTMENT 15.780 -23.422 0.000 0.000 3.803 1.087 12.213 10.833 0.000 0.145 1.873 0.000 -9.083 0.000 -13.229 -0.000
M NW APARTMENT 21.213 -17.930 0.000 0.000 3.837 1.087 12.213 5.504 0.000 0.138 0.000 0.000 -9.550 0.000 -12.953 -3.559
M SE APARTMENT 15.724 -23.585 0.000 0.000 3.807 1.087 12.213 10.734 0.000 0.145 2.047 0.000 -8.945 0.000 -13.225 -0.001
M NE APARTMENT 21.113 -18.296 0.000 0.000 3.846 1.087 12.213 5.395 0.000 0.138 0.000 0.000 -9.386 0.000 -12.929 -3.180
M N1 APARTMENT 8.308 -17.741 0.000 0.000 3.831 1.087 12.213 1.941 0.000 0.093 4.547 0.000 -6.063 0.000 -8.216 -0.000
M N2 APARTMENT 8.306 -17.729 0.000 0.000 3.832 1.087 12.213 1.941 0.000 0.093 4.533 0.000 -6.061 0.000 -8.215 -0.000
M S1 APARTMENT 4.937 -24.736 0.000 0.000 3.783 1.087 12.213 7.327 0.000 0.100 9.313 0.000 -5.546 0.000 -8.478 -0.000
M S2 APARTMENT 4.936 -24.729 0.000 0.000 3.783 1.087 12.213 7.327 0.000 0.100 9.306 0.000 -5.545 0.000 -8.478 -0.000
T SW APARTMENT 19.766 -9.949 0.000 0.000 3.855 1.087 12.213 10.768 0.000 0.200 0.000 0.000 -8.671 0.000 -17.093 -12.176
T NW APARTMENT 23.057 -7.865 0.000 0.000 3.875 1.087 12.213 5.457 0.000 0.187 0.000 0.000 -9.167 0.000 -16.794 -12.050
T SE APARTMENT 19.605 -9.861 0.000 0.000 3.860 1.087 12.213 10.687 0.000 0.200 0.000 0.000 -8.551 0.000 -17.096 -12.143
T NE APARTMENT 22.860 -7.850 0.000 0.000 3.884 1.087 12.213 5.367 0.000 0.187 0.000 0.000 -9.025 0.000 -16.777 -11.945
T N1 APARTMENT 14.313 -7.117 0.000 0.000 3.874 1.087 12.213 1.942 0.000 0.129 0.000 0.000 -5.784 0.000 -10.556 -10.100
T N2 APARTMENT 14.318 -7.114 0.000 0.000 3.874 1.087 12.213 1.941 0.000 0.129 0.000 0.000 -5.783 0.000 -10.557 -10.107
T S1 APARTMENT 11.366 -9.376 0.000 0.000 3.843 1.087 12.213 7.303 0.000 0.141 0.000 0.000 -5.290 0.000 -10.851 -10.437
T S2 APARTMENT 11.372 -9.383 0.000 0.000 3.843 1.087 12.213 7.302 0.000 0.141 0.000 0.000 -5.289 0.000 -10.852 -10.434
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 14.582 0.000 0.060 0.000 0.006 0.000 0.000 -1.091 0.000 -2.787 -10.770
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 14.582 6.479 0.242 0.000 0.206 18.956 0.000 -2.822 0.000 -37.642 -0.001
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 14.582 0.000 0.061 0.000 0.006 0.000 0.000 -1.190 0.000 -2.290 -11.169
Total Facility 299.470 -286.850 0.000 0.000 89.294 95.189 296.854 155.428 0.000 3.122 50.579 0.000 -178.813 0.000 -296.882 -227.392


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 20-JUL-14:30 0.00 -1813.07 0.00 0.00 40.66 22.70 400.26 2376.61 0.00 237.88 0.00 0.00 0.00 0.00 0.00 -1265.04
G NW APARTMENT 20-JUL-17:00 0.00 -1634.35 0.00 0.00 82.51 64.86 588.62 1642.63 0.00 304.54 0.00 0.00 0.00 0.00 0.00 -1048.81
OFFICE 23-JUL-06:01 0.00 -7353.38 0.00 0.00 0.00 416.15 294.31 918.02 0.00 0.00 5811.23 0.00 0.00 0.00 -86.33 0.00
G NE APARTMENT 19-JUL-18:00 0.00 -1200.97 0.00 0.00 140.72 87.56 588.62 562.31 0.00 111.11 0.00 0.00 0.00 0.00 0.00 -289.36
G N1 APARTMENT 19-JUL-18:45 0.00 -927.25 0.00 0.00 141.48 103.77 547.42 347.83 0.00 48.47 0.00 0.00 0.00 0.00 0.00 -261.72
G N2 APARTMENT 19-JUL-18:45 0.00 -916.76 0.00 0.00 141.36 103.77 547.42 347.82 0.00 48.38 0.00 0.00 0.00 0.00 0.00 -271.99
G S1 APARTMENT 02-SEP-12:30 0.00 -1262.82 0.00 0.00 40.75 12.97 388.49 1952.77 0.00 113.88 0.00 0.00 0.00 0.00 0.00 -1246.05
G S2 APARTMENT 02-SEP-12:30 0.00 -1350.14 0.00 0.00 40.75 12.97 388.49 1951.46 0.00 113.89 0.00 0.00 0.00 0.00 0.00 -1157.42
M SW APARTMENT 20-JUL-15:15 0.00 -5249.47 0.00 0.00 48.72 45.40 470.90 2216.12 0.00 375.94 2092.39 0.00 0.00 0.00 0.00 0.00
M NW APARTMENT 20-JUL-16:25 0.00 -4720.10 0.00 0.00 83.23 64.86 588.62 1824.77 0.00 428.25 1730.37 0.00 0.00 0.00 0.00 0.00
M SE APARTMENT 20-JUL-14:15 0.00 -4813.50 0.00 0.00 40.75 22.70 400.26 1488.85 0.00 331.98 2528.95 0.00 0.00 0.00 0.00 0.00
M NE APARTMENT 19-JUL-16:30 0.00 -3668.18 0.00 0.00 84.62 64.86 588.62 734.77 0.00 198.92 1996.40 0.00 0.00 0.00 0.00 0.00
M N1 APARTMENT 19-JUL-17:20 0.00 -2857.93 0.00 0.00 141.75 87.56 588.62 421.06 0.00 103.27 1515.67 0.00 0.00 0.00 0.00 0.00
M N2 APARTMENT 19-JUL-17:38 0.00 -2846.73 0.00 0.00 141.80 87.56 588.62 415.27 0.00 100.19 1513.29 0.00 0.00 0.00 0.00 0.00
M S1 APARTMENT 02-SEP-12:30 0.00 -3700.80 0.00 0.00 40.75 12.97 388.49 1935.42 0.00 157.28 1165.89 0.00 0.00 0.00 0.00 0.00
M S2 APARTMENT 02-SEP-12:30 0.00 -3713.09 0.00 0.00 40.75 12.97 388.49 1935.35 0.00 157.28 1178.24 0.00 0.00 0.00 0.00 0.00
T SW APARTMENT 20-JUL-15:15 0.00 -3749.38 0.00 0.00 48.77 45.40 470.90 2175.98 0.00 496.44 511.90 0.00 0.00 0.00 0.00 0.00
T NW APARTMENT 20-JUL-15:30 0.00 -3286.06 0.00 0.00 48.59 45.40 470.90 1926.51 0.00 508.58 286.08 0.00 0.00 0.00 0.00 0.00
T SE APARTMENT 20-JUL-14:15 0.00 -3408.14 0.00 0.00 40.75 22.70 400.26 1454.51 0.00 437.65 1052.26 0.00 0.00 0.00 0.00 0.00
T NE APARTMENT 20-JUL-14:00 0.00 -2743.25 0.00 0.00 40.75 12.97 382.60 858.96 0.00 422.02 1025.94 0.00 0.00 0.00 0.00 0.00
T N1 APARTMENT 20-JUL-14:00 0.00 -2130.63 0.00 0.00 40.75 12.97 382.60 523.44 0.00 254.69 916.18 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 20-JUL-14:00 0.00 -2133.60 0.00 0.00 40.75 12.97 382.60 523.38 0.00 254.68 919.21 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 20-JUL-14:15 0.00 -2790.22 0.00 0.00 40.75 22.70 400.26 1121.26 0.00 263.97 941.27 0.00 0.00 0.00 0.00 0.00
T S2 APARTMENT 20-JUL-14:15 0.00 -2790.51 0.00 0.00 40.75 22.70 400.26 1121.24 0.00 263.97 941.59 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 20-JUL-15:15 0.00 -66380.24 0.00 0.00 1188.30 4512.09 11708.34 25939.92 0.00 8170.94 14860.65 0.00 0.00 0.00 0.00 0.00


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 05-OCT-06:01 2676.75 0.00 0.00 0.00 163.44 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -328.68 0.00 -151.30 -2784.97
G NW APARTMENT 07-FEB-02:00 2389.04 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -1000.11 0.00 -1304.79 -521.62
OFFICE 01-FEB-07:01 6375.22 0.00 0.00 0.00 0.00 416.15 294.31 0.00 0.00 0.00 0.00 0.00 -289.63 0.00 -253.05 -6543.00
G NE APARTMENT 07-FEB-02:00 2369.63 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -986.93 0.00 -1304.79 -515.40
G N1 APARTMENT 27-JAN-08:15 1529.25 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -656.71 0.00 -459.95 -894.50
G N2 APARTMENT 27-JAN-08:15 1526.72 0.00 0.00 0.00 73.97 19.46 388.49 0.00 0.00 0.00 0.00 0.00 -656.74 0.00 -459.95 -891.95
G S1 APARTMENT 07-FEB-02:00 1349.01 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -612.15 0.00 -787.02 -387.33
G S2 APARTMENT 14-FEB-18:01 2045.02 0.00 0.00 0.00 168.21 87.56 588.62 0.00 0.00 0.00 0.00 0.00 -435.06 0.00 -162.39 -2291.96
M SW APARTMENT 07-MAR-14:00 4946.82 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -8.94 0.00 -2341.49 -3045.27
M NW APARTMENT 07-MAR-14:00 5402.32 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -315.59 0.00 -2341.49 -3194.12
M SE APARTMENT 07-MAR-14:00 4899.45 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -135.10 0.00 -2341.49 -2871.74
M NE APARTMENT 07-MAR-14:00 5348.57 0.00 0.00 0.00 47.42 12.97 388.49 0.00 0.00 0.00 0.00 0.00 -441.68 0.00 -2341.49 -3014.28
M N1 APARTMENT 31-OCT-06:01 3485.19 0.00 0.00 0.00 161.43 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -430.23 0.00 -202.89 -3438.26
M N2 APARTMENT 31-OCT-06:01 3494.13 0.00 0.00 0.00 161.43 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -430.23 0.00 -202.89 -3447.20
M S1 APARTMENT 22-JAN-18:01 3624.52 0.00 0.00 0.00 165.30 87.56 588.62 0.00 0.00 0.00 0.00 0.00 -408.54 0.00 -329.00 -3728.46
M S2 APARTMENT 22-JAN-18:01 3626.17 0.00 0.00 0.00 165.30 87.56 588.62 0.00 0.00 0.00 0.00 0.00 -408.52 0.00 -329.00 -3730.13
T SW APARTMENT 07-FEB-02:00 4212.53 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -1011.10 0.00 -2484.10 -1154.82
T NW APARTMENT 07-FEB-02:00 4344.30 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -1004.35 0.00 -2484.10 -1293.33
T SE APARTMENT 07-FEB-02:00 4185.63 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -995.59 0.00 -2484.10 -1143.43
T NE APARTMENT 07-FEB-02:00 4319.95 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -988.83 0.00 -2484.10 -1284.51
T N1 APARTMENT 07-FEB-02:00 2868.87 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -609.67 0.00 -1498.40 -1198.29
T N2 APARTMENT 07-FEB-02:00 2867.69 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -609.69 0.00 -1498.40 -1197.09
T S1 APARTMENT 07-FEB-02:00 2728.71 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -615.98 0.00 -1498.40 -1051.81
T S2 APARTMENT 07-FEB-02:00 2727.14 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -616.01 0.00 -1498.40 -1050.23
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 07-FEB-02:00 72143.80 0.00 0.00 0.00 4362.43 1952.47 5793.19 0.00 0.00 0.00 0.00 0.00 -19803.73 0.00 -37055.58 -27392.58



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:29

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:29

Sec1.1A-General Information

Data
Weather File Burlington International Ap VT USA TMY3 WMO#=726170
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 3134.61
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.32
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
T CORRIDOR 77.66 0.00 77.66 0.00
G CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
Totals 3134.61 2823.98 310.64  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 41.50
Number of hours cooling loads not met 4.75
Number of hours not met 46.25


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 118.46 4979.95 0.00 0.00 0.00 0.00
Exterior Lighting 40.08 0.00 0.00 0.00 0.00 0.00
Space Heating 0.00 0.00 662.58 133750.90 0.00 0.00
Space Cooling 76.53 25971.63 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Fans-Interior 213.20 6760.37 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 431.90 23590.14 0.00 0.00 0.00 0.00
Receptacle Equipment 517.65 26630.92 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 1397.82   662.58   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 517.65 1397.82
Natural Gas 0.00 662.58
Additional 0.00 0.00
Total 517.65 2060.40


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 37.79
Space Heating 0.00
Space Cooling 24.42
Fans-Interior 68.01
Service Water Heating 137.78
Receptacle Equipment 165.14
Miscellaneous 12.79
Subtotal 445.93


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 211.37
Service Water Heating 0.00
Miscellaneous 0.00
Subtotal 211.37


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 5.75
Space Heating 32.16
Space Cooling 3.71
Fans-Interior 10.35
Service Water Heating 20.96
Receptacle Equipment 25.12
Miscellaneous 1.95



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:29

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.155225
G NW APARTMENT DIRECT AIR 0.144642
OFFICE DIRECT AIR 0.467209
G NE APARTMENT DIRECT AIR 0.102738
G N1 APARTMENT DIRECT AIR 0.081372
G N2 APARTMENT DIRECT AIR 0.080346
G S1 APARTMENT DIRECT AIR 0.102534
G S2 APARTMENT DIRECT AIR 0.105700
M SW APARTMENT DIRECT AIR 0.442375
M NW APARTMENT DIRECT AIR 0.409510
M SE APARTMENT DIRECT AIR 0.403979
M NE APARTMENT DIRECT AIR 0.316977
M N1 APARTMENT DIRECT AIR 0.247463
M N2 APARTMENT DIRECT AIR 0.245663
M S1 APARTMENT DIRECT AIR 0.306644
M S2 APARTMENT DIRECT AIR 0.307767
T SW APARTMENT DIRECT AIR 0.305301
T NW APARTMENT DIRECT AIR 0.272846
T SE APARTMENT DIRECT AIR 0.283191
T NE APARTMENT DIRECT AIR 0.222310
T N1 APARTMENT DIRECT AIR 0.175684
T N2 APARTMENT DIRECT AIR 0.175777
T S1 APARTMENT DIRECT AIR 0.233858
T S2 APARTMENT DIRECT AIR 0.234585


Branch

Maximum Flow Rate [m3/s]
SPLIT GSW MAIN BRANCH 0.155225
SPLIT GNW MAIN BRANCH 0.144642
SPLIT OFFICE MAIN BRANCH 0.467209
SPLIT GNE MAIN BRANCH 0.102738
SPLIT GN1 MAIN BRANCH 0.081372
SPLIT GN2 MAIN BRANCH 0.080346
SPLIT GS1 MAIN BRANCH 0.102534
SPLIT GS2 MAIN BRANCH 0.105700
SPLIT MSW MAIN BRANCH 0.442375
SPLIT MNW MAIN BRANCH 0.409510
SPLIT MSE MAIN BRANCH 0.403979
SPLIT MNE MAIN BRANCH 0.316977
SPLIT MN1 MAIN BRANCH 0.247463
SPLIT MN2 MAIN BRANCH 0.245663
SPLIT MS1 MAIN BRANCH 0.306644
SPLIT MS2 MAIN BRANCH 0.307767
SPLIT TSW MAIN BRANCH 0.305301
SPLIT TNW MAIN BRANCH 0.272846
SPLIT TSE MAIN BRANCH 0.283191
SPLIT TNE MAIN BRANCH 0.222310
SPLIT TN1 MAIN BRANCH 0.175684
SPLIT TN2 MAIN BRANCH 0.175777
SPLIT TS1 MAIN BRANCH 0.233858
SPLIT TS2 MAIN BRANCH 0.234585


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
SPLIT GSW 0.155225
SPLIT GNW 0.144642
SPLIT OFFICE 0.467209
SPLIT GNE 0.102738
SPLIT GN1 0.081372
SPLIT GN2 0.080346
SPLIT GS1 0.102534
SPLIT GS2 0.105700
SPLIT MSW 0.442375
SPLIT MNW 0.409510
SPLIT MSE 0.403979
SPLIT MNE 0.316977
SPLIT MN1 0.247463
SPLIT MN2 0.245663
SPLIT MS1 0.306644
SPLIT MS2 0.307767
SPLIT TSW 0.305301
SPLIT TNW 0.272846
SPLIT TSE 0.283191
SPLIT TNE 0.222310
SPLIT TN1 0.175684
SPLIT TN2 0.175777
SPLIT TS1 0.233858
SPLIT TS2 0.234585


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
SPLIT GSW OA CONTROLLER 0.155225 0.026898
SPLIT GNW OA CONTROLLER 0.144642 0.025953
SPLIT OFFICE OA CONTROLLER 0.467209 0.038104
SPLIT GNE OA CONTROLLER 0.102738 0.025953
SPLIT GN1 OA CONTROLLER 0.081372 0.025953
SPLIT GN2 OA CONTROLLER 0.080346 0.025953
SPLIT GS1 OA CONTROLLER 0.102534 0.025953
SPLIT GS2 OA CONTROLLER 0.105700 0.025953
SPLIT MSW OA CONTROLLER 0.442375 0.051906
SPLIT MNW OA CONTROLLER 0.409510 0.051906
SPLIT MSE OA CONTROLLER 0.403979 0.051906
SPLIT MNE OA CONTROLLER 0.316977 0.051906
SPLIT MN1 OA CONTROLLER 0.247463 0.051906
SPLIT MN2 OA CONTROLLER 0.245663 0.051906
SPLIT MS1 OA CONTROLLER 0.306644 0.051906
SPLIT MS2 OA CONTROLLER 0.307767 0.051906
SPLIT TSW OA CONTROLLER 0.305301 0.025953
SPLIT TNW OA CONTROLLER 0.272846 0.025953
SPLIT TSE OA CONTROLLER 0.283191 0.025953
SPLIT TNE OA CONTROLLER 0.222310 0.025953
SPLIT TN1 OA CONTROLLER 0.175684 0.025953
SPLIT TN2 OA CONTROLLER 0.175777 0.025953
SPLIT TS1 OA CONTROLLER 0.233858 0.025953
SPLIT TS2 OA CONTROLLER 0.234585 0.025953


Coil:Cooling:DX:SingleSpeed

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity (gross) [W] Rated Sensible Heat Ratio
SPLIT GSW COOLING COIL 0.155225 3028.38 0.742948
SPLIT GNW COOLING COIL 0.144642 2802.54 0.745105
SPLIT OFFICE COOLING COIL 0.467209 7733.97 0.798655
SPLIT GNE COOLING COIL 0.102738 2101.91 0.728474
SPLIT GN1 COOLING COIL 0.081372 1720.68 0.718810
SPLIT GN2 COOLING COIL 0.080346 1704.02 0.717959
SPLIT GS1 COOLING COIL 0.102534 2170.39 0.718515
SPLIT GS2 COOLING COIL 0.105700 2216.37 0.721244
SPLIT MSW COOLING COIL 0.442375 8180.55 0.760109
SPLIT MNW COOLING COIL 0.409510 7602.89 0.758807
SPLIT MSE COOLING COIL 0.403979 7707.98 0.749970
SPLIT MNE COOLING COIL 0.316977 6045.70 0.750089
SPLIT MN1 COOLING COIL 0.247463 4842.64 0.742000
SPLIT MN2 COOLING COIL 0.245663 4814.15 0.741565
SPLIT MS1 COOLING COIL 0.306644 6024.82 0.740758
SPLIT MS2 COOLING COIL 0.307767 6042.44 0.740986
SPLIT TSW COOLING COIL 0.305301 5554.63 0.765507
SPLIT TNW COOLING COIL 0.272846 4986.66 0.763997
SPLIT TSE COOLING COIL 0.283191 5210.40 0.761780
SPLIT TNE COOLING COIL 0.222310 4260.45 0.748567
SPLIT TN1 COOLING COIL 0.175684 3417.11 0.743900
SPLIT TN2 COOLING COIL 0.175777 3418.88 0.743903
SPLIT TS1 COOLING COIL 0.233858 4330.78 0.759639
SPLIT TS2 COOLING COIL 0.234585 4342.08 0.759801


AirLoopHVAC:Unitary:Furnace:HeatCool

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
SPLIT GSW FURNACE WITH DX COOLING 0.155225 0.155225 0.155225 0.155225 3969.55 3028.38 1.00
SPLIT GNW FURNACE WITH DX COOLING 0.144642 0.144642 0.144642 0.144642 3939.34 2802.54 1.00
SPLIT OFFICE FURNACE WITH DX COOLING 0.467209 0.467209 0.467209 0.467209 6758.44 7733.97 1.00
SPLIT GNE FURNACE WITH DX COOLING 0.102738 0.102738 0.102738 0.102738 3949.77 2101.91 1.00
SPLIT GN1 FURNACE WITH DX COOLING 0.081372 0.081372 0.081372 0.081372 3038.82 1720.68 1.00
SPLIT GN2 FURNACE WITH DX COOLING 0.080346 0.080346 0.080346 0.080346 3039.06 1704.02 1.00
SPLIT GS1 FURNACE WITH DX COOLING 0.102534 0.102534 0.102534 0.102534 3022.61 2170.39 1.00
SPLIT GS2 FURNACE WITH DX COOLING 0.105700 0.105700 0.105700 0.105700 3157.36 2216.37 1.00
SPLIT MSW FURNACE WITH DX COOLING 0.442375 0.442375 0.442375 0.442375 7653.02 8180.55 1.00
SPLIT MNW FURNACE WITH DX COOLING 0.409510 0.409510 0.409510 0.409510 7697.97 7602.89 1.00
SPLIT MSE FURNACE WITH DX COOLING 0.403979 0.403979 0.403979 0.403979 7680.34 7707.98 1.00
SPLIT MNE FURNACE WITH DX COOLING 0.316977 0.316977 0.316977 0.316977 7725.31 6045.70 1.00
SPLIT MN1 FURNACE WITH DX COOLING 0.247463 0.247463 0.247463 0.247463 5436.16 4842.64 1.00
SPLIT MN2 FURNACE WITH DX COOLING 0.245663 0.245663 0.245663 0.245663 5436.81 4814.15 1.00
SPLIT MS1 FURNACE WITH DX COOLING 0.306644 0.306644 0.306644 0.306644 5393.69 6024.82 1.00
SPLIT MS2 FURNACE WITH DX COOLING 0.307767 0.307767 0.307767 0.307767 5394.34 6042.44 1.00
SPLIT TSW FURNACE WITH DX COOLING 0.305301 0.305301 0.305301 0.305301 5631.73 5554.63 1.00
SPLIT TNW FURNACE WITH DX COOLING 0.272846 0.272846 0.272846 0.272846 5657.45 4986.66 1.00
SPLIT TSE FURNACE WITH DX COOLING 0.283191 0.283191 0.283191 0.283191 5646.20 5210.40 1.00
SPLIT TNE FURNACE WITH DX COOLING 0.222310 0.222310 0.222310 0.222310 5671.92 4260.45 1.00
SPLIT TN1 FURNACE WITH DX COOLING 0.175684 0.175684 0.175684 0.175684 4418.61 3417.11 1.00
SPLIT TN2 FURNACE WITH DX COOLING 0.175777 0.175777 0.175777 0.175777 4418.97 3418.88 1.00
SPLIT TS1 FURNACE WITH DX COOLING 0.233858 0.233858 0.233858 0.233858 4391.11 4330.78 1.00
SPLIT TS2 FURNACE WITH DX COOLING 0.234585 0.234585 0.234585 0.234585 4391.48 4342.08 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
SPLIT GSW SUPPLY FAN 0.155225
SPLIT GNW SUPPLY FAN 0.144642
SPLIT OFFICE SUPPLY FAN 0.467209
SPLIT GNE SUPPLY FAN 0.102738
SPLIT GN1 SUPPLY FAN 0.081372
SPLIT GN2 SUPPLY FAN 0.080346
SPLIT GS1 SUPPLY FAN 0.102534
SPLIT GS2 SUPPLY FAN 0.105700
SPLIT MSW SUPPLY FAN 0.442375
SPLIT MNW SUPPLY FAN 0.409510
SPLIT MSE SUPPLY FAN 0.403979
SPLIT MNE SUPPLY FAN 0.316977
SPLIT MN1 SUPPLY FAN 0.247463
SPLIT MN2 SUPPLY FAN 0.245663
SPLIT MS1 SUPPLY FAN 0.306644
SPLIT MS2 SUPPLY FAN 0.307767
SPLIT TSW SUPPLY FAN 0.305301
SPLIT TNW SUPPLY FAN 0.272846
SPLIT TSE SUPPLY FAN 0.283191
SPLIT TNE SUPPLY FAN 0.222310
SPLIT TN1 SUPPLY FAN 0.175684
SPLIT TN2 SUPPLY FAN 0.175777
SPLIT TS1 SUPPLY FAN 0.233858
SPLIT TS2 SUPPLY FAN 0.234585


Coil:Heating:Gas

Nominal Capacity [W]
SPLIT GSW HEATING COIL 3969.55
SPLIT GNW HEATING COIL 3939.34
SPLIT OFFICE HEATING COIL 6758.44
SPLIT GNE HEATING COIL 3949.77
SPLIT GN1 HEATING COIL 3038.82
SPLIT GN2 HEATING COIL 3039.06
SPLIT GS1 HEATING COIL 3022.61
SPLIT GS2 HEATING COIL 3157.36
SPLIT MSW HEATING COIL 7653.02
SPLIT MNW HEATING COIL 7697.97
SPLIT MSE HEATING COIL 7680.34
SPLIT MNE HEATING COIL 7725.31
SPLIT MN1 HEATING COIL 5436.16
SPLIT MN2 HEATING COIL 5436.81
SPLIT MS1 HEATING COIL 5393.69
SPLIT MS2 HEATING COIL 5394.34
SPLIT TSW HEATING COIL 5631.73
SPLIT TNW HEATING COIL 5657.45
SPLIT TSE HEATING COIL 5646.20
SPLIT TNE HEATING COIL 5671.92
SPLIT TN1 HEATING COIL 4418.61
SPLIT TN2 HEATING COIL 4418.97
SPLIT TS1 HEATING COIL 4391.11
SPLIT TS2 HEATING COIL 4391.48



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:29

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW1 S SWA |
G WWALL SWA GWINDOW1 W SWA |
G NWALL NWA GWINDOW1 N NWA |
G WWALL NWA GWINDOW1 W NWA |
G SWALL SEA GWINDOW1 S SEA |
G EWALL SEA GWINDOW1 E SEA |
G NWALL NEA GWINDOW1 N NEA |
G EWALL NEA GWINDOW1 E NEA |
G NWALL N1A GWINDOW1 N N1A |
G NWALL N2A GWINDOW1 N N2A |
G SWALL S1A GWINDOW1 S S1A |
G SWALL S2A GWINDOW1 S S2A |
M WWALL SWA MWINDOW1 W SWA |
M SWALL SWA MWINDOW1 S SWA |
M NWALL NWA MWINDOW1 N NWA |
M WWALL NWA MWINDOW1 W NWA |
M EWALL SEA MWINDOW1 E SEA |
M SWALL SEA MWINDOW1 S SEA |
M NWALL NEA MWINDOW1 N NEA |
M EWALL NEA MWINDOW1 E NEA |
M NWALL N1A MWINDOW1 N N1A |
M NWALL N2A MWINDOW1 N N2A |
M SWALL S1A MWINDOW1 S S1A |
M SWALL S2A MWINDOW1 S S2A |
T WWALL SWA TWINDOW1 W SWA |
T SWALL SWA TWINDOW1 S SWA |
T NWALL NWA TWINDOW1 N NWA |
T WWALL NWA TWINDOW1 W NWA |
T EWALL SEA TWINDOW1 E SEA |
T SWALL SEA TWINDOW1 S SEA |
T NWALL NEA TWINDOW1 N NEA |
T EWALL NEA TWINDOW1 E NEA |
T NWALL N1A TWINDOW1 N N1A |
T NWALL N2A TWINDOW1 N N2A |
T SWALL S1A TWINDOW1 S S1A |
T SWALL S2A TWINDOW1 S S2A |
T EWALL C TWINDOW14 |
G EWALL C ENTRANCE DOOR |
M EWALL C MWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:29

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.77 -0.5
April 22.14 7.83
May 22.62 13.82
June 24.19 19.28
July 24.32 21.06
August 24.29 19.79
September 23.75 15.09
October 22.07 8.66
November 21.77 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.67 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.32 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.71 -0.5
April 21.99 7.83
May 22.44 13.82
June 24.18 19.28
July 24.31 21.06
August 24.24 19.79
September 23.55 15.09
October 21.83 8.66
November 21.70 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.59 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.31 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 18.41 -7.2
February 18.88 -5.6
March 20.36 -0.5
April 22.30 7.83
May 23.69 13.82
June 25.69 19.28
July 26.22 21.06
August 25.88 19.79
September 25.07 15.09
October 22.72 8.66
November 20.99 2.78
December 19.62 -1.5
     
Annual Sum or Average 22.50 7.87
Minimum of Months 18.41 -7.2
Maximum of Months 26.22 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.70 -0.5
April 21.95 7.83
May 22.36 13.82
June 24.16 19.28
July 24.31 21.06
August 24.23 19.79
September 23.47 15.09
October 21.78 8.66
November 21.70 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.57 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.31 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.70 -0.5
April 21.90 7.83
May 22.23 13.82
June 24.13 19.28
July 24.30 21.06
August 24.21 19.79
September 23.57 15.09
October 21.81 8.66
November 21.70 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.56 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.30 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.70 -0.5
April 21.89 7.83
May 22.23 13.82
June 24.13 19.28
July 24.30 21.06
August 24.21 19.79
September 23.57 15.09
October 21.81 8.66
November 21.70 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.56 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.30 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.75 -0.5
April 22.08 7.83
May 22.48 13.82
June 24.18 19.28
July 24.32 21.06
August 24.30 19.79
September 23.87 15.09
October 22.11 8.66
November 21.78 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.67 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.32 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.76 -0.5
April 22.09 7.83
May 22.52 13.82
June 24.21 19.28
July 24.33 21.06
August 24.31 19.79
September 23.89 15.09
October 22.13 8.66
November 21.78 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.68 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.33 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.73 -5.6
March 22.09 -0.5
April 23.01 7.83
May 24.21 13.82
June 24.40 19.28
July 24.40 21.06
August 24.39 19.79
September 24.14 15.09
October 23.21 8.66
November 22.03 2.78
December 21.71 -1.5
     
Annual Sum or Average 23.09 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.40 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.80 -0.5
April 22.64 7.83
May 24.06 13.82
June 24.40 19.28
July 24.40 21.06
August 24.38 19.79
September 23.96 15.09
October 22.37 8.66
November 21.74 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.91 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.40 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.72 -5.6
March 22.07 -0.5
April 23.03 7.83
May 24.21 13.82
June 24.40 19.28
July 24.40 21.06
August 24.39 19.79
September 24.13 15.09
October 23.17 8.66
November 22.02 2.78
December 21.71 -1.5
     
Annual Sum or Average 23.09 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.40 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.76 -0.5
April 22.59 7.83
May 24.02 13.82
June 24.39 19.28
July 24.40 21.06
August 24.38 19.79
September 23.91 15.09
October 22.22 8.66
November 21.73 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.88 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.40 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.78 -0.5
April 22.67 7.83
May 24.09 13.82
June 24.40 19.28
July 24.40 21.06
August 24.38 19.79
September 24.09 15.09
October 22.51 8.66
November 21.76 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.94 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.40 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.77 -0.5
April 22.67 7.83
May 24.09 13.82
June 24.40 19.28
July 24.40 21.06
August 24.38 19.79
September 24.08 15.09
October 22.49 8.66
November 21.76 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.94 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.40 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.75 -5.6
March 22.16 -0.5
April 23.23 7.83
May 24.29 13.82
June 24.40 19.28
July 24.40 21.06
August 24.40 19.79
September 24.27 15.09
October 23.64 8.66
November 22.20 2.78
December 21.73 -1.5
     
Annual Sum or Average 23.19 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.40 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.75 -5.6
March 22.16 -0.5
April 23.23 7.83
May 24.29 13.82
June 24.40 19.28
July 24.40 21.06
August 24.40 19.79
September 24.27 15.09
October 23.63 8.66
November 22.20 2.78
December 21.73 -1.5
     
Annual Sum or Average 23.19 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.40 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.73 -5.6
March 21.99 -0.5
April 22.58 7.83
May 23.62 13.82
June 24.31 19.28
July 24.34 21.06
August 24.30 19.79
September 23.68 15.09
October 22.50 8.66
November 21.88 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.87 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.34 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.80 -0.5
April 22.38 7.83
May 23.47 13.82
June 24.31 19.28
July 24.34 21.06
August 24.25 19.79
September 23.49 15.09
October 22.08 8.66
November 21.72 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.75 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.34 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.72 -5.6
March 21.99 -0.5
April 22.59 7.83
May 23.62 13.82
June 24.31 19.28
July 24.34 21.06
August 24.30 19.79
September 23.67 15.09
October 22.47 8.66
November 21.87 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.86 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.34 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.76 -0.5
April 22.36 7.83
May 23.43 13.82
June 24.29 19.28
July 24.33 21.06
August 24.26 19.79
September 23.44 15.09
October 21.98 8.66
November 21.71 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.73 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.33 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.76 -0.5
April 22.36 7.83
May 23.53 13.82
June 24.32 19.28
July 24.34 21.06
August 24.26 19.79
September 23.53 15.09
October 22.07 8.66
November 21.71 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.76 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.34 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.70 -5.6
March 21.76 -0.5
April 22.36 7.83
May 23.53 13.82
June 24.32 19.28
July 24.34 21.06
August 24.27 19.79
September 23.53 15.09
October 22.07 8.66
November 21.71 2.78
December 21.70 -1.5
     
Annual Sum or Average 22.75 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.34 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.74 -5.6
March 22.03 -0.5
April 22.67 7.83
May 23.76 13.82
June 24.34 19.28
July 24.36 21.06
August 24.32 19.79
September 23.81 15.09
October 22.68 8.66
November 21.94 2.78
December 21.71 -1.5
     
Annual Sum or Average 22.93 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.36 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 -7.2
February 21.74 -5.6
March 22.03 -0.5
April 22.67 7.83
May 23.76 13.82
June 24.34 19.28
July 24.36 21.06
August 24.32 19.79
September 23.81 15.09
October 22.68 8.66
November 21.94 2.78
December 21.71 -1.5
     
Annual Sum or Average 22.93 7.87
Minimum of Months 21.70 -7.2
Maximum of Months 24.36 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 20.10 -7.2
February 20.35 -5.6
March 21.30 -0.5
April 23.08 7.83
May 24.92 13.82
June 26.33 19.28
July 26.53 21.06
August 26.33 19.79
September 25.03 15.09
October 22.85 8.66
November 21.40 2.78
December 20.60 -1.5
     
Annual Sum or Average 23.25 7.87
Minimum of Months 20.10 -7.2
Maximum of Months 26.53 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 16.95 -7.2
February 17.27 -5.6
March 18.45 -0.5
April 20.55 7.83
May 22.18 13.82
June 24.99 19.28
July 25.64 21.06
August 25.35 19.79
September 23.95 15.09
October 20.87 8.66
November 19.17 2.78
December 18.07 -1.5
     
Annual Sum or Average 21.14 7.87
Minimum of Months 16.95 -7.2
Maximum of Months 25.64 21.06



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2015-09-09 18:47:29

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.31 -7.2
February 22.46 -5.6
March 23.08 -0.5
April 24.59 7.83
May 26.09 13.82
June 26.69 19.28
July 26.77 21.06
August 26.69 19.79
September 26.14 15.09
October 24.58 8.66
November 23.16 2.78
December 22.52 -1.5
     
Annual Sum or Average 24.60 7.87
Minimum of Months 22.31 -7.2
Maximum of Months 26.77 21.06



Table of Contents

Report: PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2015-09-09 18:47:29

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY [Invalid/Undefined] HEATREJECTION:ELECTRICITY [Invalid/Undefined] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined]
January 0.116445E+12 73318.504 31-JAN-18:45 4979.953 26630.920 6760.374 0.000 0.000 2553.000 0.000 0.000 0.000 0.000 0.000 32394.257 0.000 0.000 0.000
February 0.105425E+12 73333.480 19-FEB-18:30 4979.953 26630.920 6760.374 0.000 0.000 2553.000 0.000 0.000 0.000 0.000 0.000 32409.232 0.000 0.000 0.000
March 0.116145E+12 73327.477 01-MAR-18:15 4979.953 26630.920 6760.374 0.000 0.000 2553.000 0.000 0.000 0.000 0.000 0.000 32403.229 0.000 0.000 0.000
April 0.112443E+12 75864.723 21-APR-17:00 4979.953 26630.920 6760.374 0.000 10835.828 0.000 0.000 0.000 0.000 0.000 0.000 26657.647 0.000 0.000 0.000
May 0.116916E+12 76694.903 31-MAY-17:15 4979.953 26630.920 6760.374 0.000 14732.560 0.000 0.000 0.000 0.000 0.000 0.000 23591.095 0.000 0.000 0.000
June 0.122710E+12 82223.706 16-JUN-16:45 4276.255 26630.920 6760.374 0.000 23410.657 0.000 0.000 0.000 0.000 0.000 0.000 21145.500 0.000 0.000 0.000
July 0.130628E+12 87933.019 20-JUL-17:00 4979.953 26630.920 6760.374 0.000 25971.630 0.000 0.000 0.000 0.000 0.000 0.000 23590.141 0.000 0.000 0.000
August 0.127762E+12 84690.413 04-AUG-17:00 4979.953 26630.920 6760.374 0.000 18621.816 0.000 0.000 0.000 0.000 0.000 0.000 27697.350 0.000 0.000 0.000
September 0.113792E+12 77057.641 01-SEP-17:45 4979.953 26630.920 6760.374 0.000 10484.264 0.000 0.000 0.000 0.000 0.000 0.000 28202.129 0.000 0.000 0.000
October 0.111249E+12 67552.248 30-OCT-17:15 4979.953 26630.920 6760.374 0.000 0.000 2553.000 0.000 0.000 0.000 0.000 0.000 26628.000 0.000 0.000 0.000
November 0.109321E+12 70278.311 20-NOV-18:00 4979.953 26630.920 6760.374 0.000 0.000 2553.000 0.000 0.000 0.000 0.000 0.000 29354.064 0.000 0.000 0.000
December 0.114985E+12 71356.306 01-DEC-18:45 4979.953 26630.920 6760.374 0.000 0.000 2553.000 0.000 0.000 0.000 0.000 0.000 30432.058 0.000 0.000 0.000
                                     
Annual Sum or Average 0.139782E+13                 0.000 0.000 0.000 0.000 0.000   0.000 0.000 0.000
Minimum of Months 0.105425E+12 67552.248   4276.255 26630.920 6760.374 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 21145.500 0.000 0.000 0.000
Maximum of Months 0.130628E+12 87933.019   4979.953 26630.920 6760.374 0.000 25971.630 2553.000 0.000 0.000 0.000 0.000 0.000 32409.232 0.000 0.000 0.000



Table of Contents

Report: PEAK GAS DEMAND

For: Meter

Timestamp: 2015-09-09 18:47:29

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC {AT MAX/MIN} [W] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT [Invalid/Undefined] WATERSYSTEMS:GAS [Invalid/Undefined] WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] HEATING:GAS {AT MAX/MIN} [W]
January 0.170884E+12 133750.900 27-JAN-06:00 133750.900 0.000 0.000 0.000 0.000 0.000 133750.900
February 0.140609E+12 129076.352 07-FEB-01:00 129076.352 0.000 0.000 0.000 0.000 0.000 129076.352
March 0.983651E+11 122542.070 07-MAR-07:15 122542.070 0.000 0.000 0.000 0.000 0.000 122542.070
April 0.305308E+11 88389.047 09-APR-02:00 88389.047 0.000 0.000 0.000 0.000 0.000 88389.047
May 0.270640E+10 22885.253 08-MAY-02:00 22885.253 0.000 0.000 0.000 0.000 0.000 22885.253
June 0.000 0.000 01-JUN-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
July 0.000 0.000 01-JUL-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 0.191548E+08 1828.621 27-AUG-04:00 1828.621 0.000 0.000 0.000 0.000 0.000 1828.621
September 0.178062E+10 16678.947 30-SEP-04:00 16678.947 0.000 0.000 0.000 0.000 0.000 16678.947
October 0.178715E+11 41080.295 31-OCT-06:15 41080.295 0.000 0.000 0.000 0.000 0.000 41080.295
November 0.721677E+11 72596.514 29-NOV-07:00 72596.514 0.000 0.000 0.000 0.000 0.000 72596.514
December 0.127645E+12 122893.980 17-DEC-07:15 122893.980 0.000 0.000 0.000 0.000 0.000 122893.980
                     
Annual Sum or Average 0.662579E+12       0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.000 0.000   0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.170884E+12 133750.900   133750.900 0.000 0.000 0.000 0.000 0.000 133750.900