Table of Contents

Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:47

Tabular Output Report in Format: HTML

Building: Mid-Rise Apartment

Environment: Albuquerque Intl Arpt Isis NM USA TMY3 WMO#=723650

Simulation Timestamp: 2015-09-09 18:47:12


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:12

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 1599.19 510.17 566.29
Net Site Energy 1599.19 510.17 566.29
Total Source Energy 4799.71 1531.20 1699.63
Net Source Energy 4799.71 1531.20 1699.63


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 0.300
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil #1 1.050
Fuel Oil #2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 3134.61
Net Conditioned Building Area 2823.98
Unconditioned Building Area 310.64


End Uses

Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 0.00 127.18 0.00 0.00 0.00 0.00
Cooling 147.01 0.00 0.00 0.00 0.00 0.00
Interior Lighting 118.46 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 40.11 0.00 0.00 0.00 0.00 0.00
Interior Equipment 517.65 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 264.93 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 383.84 0.00 0.00 0.00 0.00 1874.72
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 1472.01 127.18 0.00 0.00 0.00 1874.72
Note: Natural gas appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Additional Fuel [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating General 0.00 127.18 0.00 0.00 0.00 0.00
Cooling General 147.01 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 96.36 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 22.11 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 40.11 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 517.65 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 264.93 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 383.84 0.00 0.00 0.00 0.00 1874.72
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 56.15 0.00 0.00 0.00 0.00 0.00
HVAC 281.79 45.04 0.00 0.00 0.00 0.66
Other 183.31 0.00 0.00 0.00 0.00 0.00
Total 521.25 45.04 0.00 0.00 0.00 0.66


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Additional Fuel Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 50.59 0.00 0.00 0.00 0.00 0.00
HVAC 253.87 40.57 0.00 0.00 0.00 0.60
Other 165.14 0.00 0.00 0.00 0.00 0.00
Total 469.60 40.57 0.00 0.00 0.00 0.60


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.00 0.00
High Temperature Geothermal* 0.00 0.00
Photovoltaic Power 0.00 0.00
Wind Power 0.00 0.00
Net Decrease in On-Site Storage 0.00 0.00
Total On-Site Electric Sources 0.00 0.00
     
Electricity Coming From Utility 1472.01 100.00
Surplus Electricity Going To Utility 0.00 0.00
Net Electricity From Utility 1472.01 100.00
     
Total On-Site and Utility Electric Sources 1472.01 100.00
Total Electricity End Uses 1472.01 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 1874.72 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 1874.72 100.00
Total Water End Uses 1874.72 100.00


Comfort and Setpoint Not Met Summary

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Facility [Hours]
Time Setpoint Not Met During Occupied Heating 35.75
Time Setpoint Not Met During Occupied Cooling 2.25
Time Not Comfortable Based on Simple ASHRAE 55-2004 1544.75


Note 1: An asterisk (*) indicates that the feature is not yet implemented.


Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary

MONTHLY INDOOR TEMP

| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |

PEAK ELECTRICAL DEMAND

| Meter |

PEAK GAS DEMAND

| Meter |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:12

General

Value
Program Version and Build EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:47
RunPeriod Albuquerque Intl Arpt Isis NM USA TMY3 WMO#=723650
Weather File Albuquerque Intl Arpt Isis NM USA TMY3 WMO#=723650
Latitude [deg] 35.04
Longitude [deg] -106.6
Elevation [m] 1619.00
Time Zone -7.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1542.04 564.80 206.22 564.80 206.22
Window Opening Area [m2] 306.92 112.97 37.16 112.97 43.82
Window-Wall Ratio [%] 19.90 20.00 18.02 20.00 21.25


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 1501.17 564.80 185.79 564.80 185.79
Window Opening Area [m2] 300.26 112.97 37.16 112.97 37.16
Window-Wall Ratio [%] 20.00 20.00 20.00 20.00 20.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 783.65
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Gross Wall Area [m2] Window Glass Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
G SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
G NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
OFFICE 88.25 Yes Yes 268.97 1.00 58.52 11.71 26.1977 88.25 6.6700
G NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
G N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
G N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
G S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
G S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
M SW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 3.6746 35.30 6.6700
M NW APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 3.6746 35.30 6.6700
M SE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 3.6746 35.30 6.6700
M NE APARTMENT 88.25 Yes Yes 268.97 2.00 58.52 11.71 3.6746 35.30 6.6700
M N1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 3.6746 35.30 6.6700
M N2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 3.6746 35.30 6.6700
M S1 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 3.6746 35.30 6.6700
M S2 APARTMENT 88.25 Yes Yes 268.97 2.00 35.30 7.06 3.6746 35.30 6.6700
T SW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
T NW APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
T SE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
T NE APARTMENT 88.25 Yes Yes 268.97 1.00 58.52 11.71 3.6746 35.30 6.6700
T N1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
T N2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
T S1 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
T S2 APARTMENT 88.25 Yes Yes 268.97 1.00 35.30 7.06 3.6746 35.30 6.6700
T CORRIDOR 77.66 No Yes 236.69 1.00 10.22 1.11 5.9540   0.0000
G CORRIDOR 77.66 No Yes 236.69 1.00 10.22 3.32 5.9540   208.8202
M CORRIDOR 77.66 No Yes 236.69 2.00 10.22 1.11 5.9540   0.0000
Total 3134.61     9553.84   1542.04 306.92 4.5346 39.93 11.1825
Conditioned Total 2823.98     8607.06   1501.17 300.26 4.3785 35.97 6.6700
Unconditioned Total 310.64     946.78   40.87 6.66 5.9540   52.2051
Not Part of Total 0.00     0.00   0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:12

End Uses

Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 21-JUL-17:30 18-JAN-01:15 - - - 01-JAN-07:15
Heating 0.00 60925.70 0.00 0.00 0.00 0.00
Cooling 22755.18 0.00 0.00 0.00 0.00 0.00
Interior Lighting 4979.95 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 26630.92 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Fans 8400.98 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 19573.81 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00
             
Total End Uses 82340.84 60925.70 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Propane [W] District Cooling [W] Steam [W] Water [m3/s]
Heating General 0.00 60925.70 0.00 0.00 0.00 0.00
Cooling General 22755.18 0.00 0.00 0.00 0.00 0.00
Interior Lighting GeneralLights 4056.31 0.00 0.00 0.00 0.00 0.00
  GeneralLights-plugin 923.64 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 26630.92 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00
  General 8400.98 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Water Heater 19573.81 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:12

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Additional Fuel [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 0.00 137.86 0.00 0.00 0.00
Cooling 465.58 0.00 0.00 0.00 0.00
Interior Lighting 375.17 0.00 0.00 0.00 0.00
Exterior Lighting 127.04 0.00 0.00 0.00 0.00
Interior Equipment 1639.40 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 839.04 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 1215.61 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 4661.85 137.86 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 48.82 0.00 0.00 0.00
Cooling 164.87 0.00 0.00 0.00 0.00
Interior Lighting 132.85 0.00 0.00 0.00 0.00
Exterior Lighting 44.99 0.00 0.00 0.00 0.00
Interior Equipment 580.53 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 297.11 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 430.46 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1650.81 48.82 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Additional Fuel [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 0.00 48.82 0.00 0.00 0.00
Cooling 164.87 0.00 0.00 0.00 0.00
Interior Lighting 132.85 0.00 0.00 0.00 0.00
Exterior Lighting 44.99 0.00 0.00 0.00 0.00
Interior Equipment 580.53 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00
Fans 297.11 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00
Water Systems 430.46 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00
           
Total Source Energy End Use Components 1650.81 48.82 0.00 0.00 0.00



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:12

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB -7.90 0.00 -7.90 Wetbulb [C] 3.20 0.00
ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 35.10 13.50 15.70 Wetbulb [C] 4.40 220.00


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:12

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
G SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR SWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
G GFLOOR NWA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR SEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
G GFLOOR NEA EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
G GFLOOR N2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S1A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
G SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
G GFLOOR S2A EXT_SLAB_8IN_WITH_CARPET 0.30 1.827 3.285 88.25 90.00 180.00  
M WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 46.45 270.00 90.00 W
M SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
M NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 46.45 270.00 90.00 W
M EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 46.45 90.00 90.00 E
M SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
M NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 46.45 90.00 90.00 E
M NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 70.60 0.00 90.00 N
M SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
M SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 70.60 180.00 90.00 S
T WWALL SWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T SWALL SWA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SWA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL NWA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T WWALL NWA RES_EXT_WALL 0.30 0.363 0.384 23.22 270.00 90.00 W
T ROOF NWA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T EWALL SEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T SWALL SEA RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF SEA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL NEA RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T EWALL NEA RES_EXT_WALL 0.30 0.363 0.384 23.22 90.00 90.00 E
T ROOF NEA RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL N1A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N1A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T NWALL N2A RES_EXT_WALL 0.30 0.363 0.384 35.30 0.00 90.00 N
T ROOF N2A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T SWALL S1A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S1A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T SWALL S2A RES_EXT_WALL 0.30 0.363 0.384 35.30 180.00 90.00 S
T ROOF S2A RES_ROOF 0.30 0.269 0.283 88.25 180.00 0.00  
T WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
T EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
T ROOF C RES_ROOF 0.30 0.269 0.283 77.66 180.00 0.00  
G WWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 270.00 90.00 W
G EWALL C RES_EXT_WALL 0.30 0.363 0.384 5.11 90.00 90.00 E
G FLOOR C INT_SLAB_CEILING 0.30 1.986 3.839 77.66 90.00 180.00  
M WWALL C RES_EXT_WALL 0.30 0.363 0.384 10.22 270.00 90.00 W
M EWALL C RES_EXT_WALL 0.30 0.363 0.384 10.22 90.00 90.00 E


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
GWINDOW1 S SWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL SWA 180.00 90.00 S
GWINDOW1 W SWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G WWALL SWA 270.00 90.00 W
GWINDOW1 N NWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL NWA 0.00 90.00 N
GWINDOW1 W NWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G WWALL NWA 270.00 90.00 W
GWINDOW1 S SEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL SEA 180.00 90.00 S
GWINDOW1 E SEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G EWALL SEA 90.00 90.00 E
GWINDOW1 N NEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL NEA 0.00 90.00 N
GWINDOW1 E NEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No G EWALL NEA 90.00 90.00 E
GWINDOW1 N N1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL N1A 0.00 90.00 N
GWINDOW1 N N2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G NWALL N2A 0.00 90.00 N
GWINDOW1 S S1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL S1A 180.00 90.00 S
GWINDOW1 S S2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No G SWALL S2A 180.00 90.00 S
MWINDOW1 W SWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M WWALL SWA 270.00 90.00 W
MWINDOW1 S SWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL SWA 180.00 90.00 S
MWINDOW1 N NWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL NWA 0.00 90.00 N
MWINDOW1 W NWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M WWALL NWA 270.00 90.00 W
MWINDOW1 E SEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M EWALL SEA 90.00 90.00 E
MWINDOW1 S SEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL SEA 180.00 90.00 S
MWINDOW1 N NEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL NEA 0.00 90.00 N
MWINDOW1 E NEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 9.29 2.653 0.426 0.308     No M EWALL NEA 90.00 90.00 E
MWINDOW1 N N1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL N1A 0.00 90.00 N
MWINDOW1 N N2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M NWALL N2A 0.00 90.00 N
MWINDOW1 S S1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL S1A 180.00 90.00 S
MWINDOW1 S S2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 14.12 2.653 0.426 0.308     No M SWALL S2A 180.00 90.00 S
TWINDOW1 W SWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T WWALL SWA 270.00 90.00 W
TWINDOW1 S SWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL SWA 180.00 90.00 S
TWINDOW1 N NWA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL NWA 0.00 90.00 N
TWINDOW1 W NWA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T WWALL NWA 270.00 90.00 W
TWINDOW1 E SEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T EWALL SEA 90.00 90.00 E
TWINDOW1 S SEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL SEA 180.00 90.00 S
TWINDOW1 N NEA WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL NEA 0.00 90.00 N
TWINDOW1 E NEA WINDOW_U_0.52_SHGC_0.40 4.65 0.00 0.00 4.65 4.65 2.653 0.426 0.308     No T EWALL NEA 90.00 90.00 E
TWINDOW1 N N1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL N1A 0.00 90.00 N
TWINDOW1 N N2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T NWALL N2A 0.00 90.00 N
TWINDOW1 S S1A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL S1A 180.00 90.00 S
TWINDOW1 S S2A WINDOW_U_0.52_SHGC_0.40 7.06 0.00 0.00 7.06 7.06 2.653 0.426 0.308     No T SWALL S2A 180.00 90.00 S
TWINDOW14 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 1.11 2.653 0.426 0.308     No T EWALL C 270.00 90.00 W
ENTRANCE DOOR WINDOW_U_0.52_SHGC_0.40 3.32 0.00 0.00 3.32 3.32 2.653 0.426 0.308     No G EWALL C 270.00 90.00 W
MWINDOW14 WINDOW_U_0.52_SHGC_0.40 1.11 0.00 0.00 1.11 2.23 2.653 0.426 0.308     No M EWALL C 270.00 90.00 W
Total or Average           306.92 2.653 0.426 0.308              
North Total or Average           112.97 2.653 0.426 0.308              
Non-North Total or Average           193.95 2.653 0.426 0.308              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:12

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
GWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
GWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
GWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
GWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
GWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
MWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
MWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
MWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 W SWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW1 S SWA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 N NWA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 W NWA 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00 1.00
TWINDOW1 E SEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 S SEA 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 N NEA 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 E NEA 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
TWINDOW1 N N1A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 N N2A 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TWINDOW1 S S1A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW1 S S2A 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
TWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
ENTRANCE DOOR 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00
MWINDOW14 1.00 1.00 0.00 1.00 1.00 0.00 1.00 1.00 0.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:12

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
LIGHTING_HARDWIRED_GSW G SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GNW G NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_OFFICE OFFICE 13.0989 88.25 1155.96 GeneralLights LTG_OFF_SCH 62.17 168.00 60.95 0.0000 Y 13.23
LIGHTING_HARDWIRED_GNE G NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GN1 G N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GN2 G N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GS1 G S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GS2 G S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MSW M SW APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MNW M NW APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MSE M SE APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MNE M NE APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MN1 M N1 APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MN2 M N2 APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MS1 M S1 APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_MS2 M S2 APARTMENT 2.7059 176.50 477.59 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TSW T SW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TNW T NW APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TSE T SE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TNE T NE APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TN1 T N1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TN2 T N2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TS1 T S1 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_TS2 T S2 APARTMENT 2.7059 88.25 238.79 GeneralLights LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.80
LIGHTING_HARDWIRED_GC G CORRIDOR 5.9540 77.66 462.39 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 14.58
LIGHTING_HARDWIRED_MC M CORRIDOR 5.9540 155.32 924.77 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 14.58
LIGHTING_HARDWIRED_TC T CORRIDOR 5.9540 77.66 462.39 GeneralLights LTG_COR_SCH 168.00 168.00 168.00 0.0000 N 14.58
LIGHTING_PLUGIN_GSW G SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_GNW G NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_OFFICE OFFICE 13.0989 88.25 1155.96 GeneralLights-plugin LTG_OFF_SCH 62.17 168.00 60.95 0.0000 Y 13.23
LIGHTING_PLUGIN_GNE G NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_GN1 G N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_GN2 G N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_GS1 G S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_GS2 G S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MSW M SW APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MNW M NW APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MSE M SE APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MNE M NE APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MN1 M N1 APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MN2 M N2 APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MS1 M S1 APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_MS2 M S2 APARTMENT 0.9688 176.50 170.98 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TSW T SW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TNW T NW APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TSE T SE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TNE T NE APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TN1 T N1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TN2 T N2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TS1 T S1 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
LIGHTING_PLUGIN_TS2 T S2 APARTMENT 0.9688 88.25 85.49 GeneralLights-plugin LTG_APT_SCH 17.85 168.00 17.85 0.0000 Y 0.29
Interior Lighting Total   2.3855 5958.59 14214.30               95.19


Daylighting

Zone Daylighting Type Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None            


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
FACADE LIGHTING 2553.00 AstronomicalClock -   83.70 83.70 40.11
Exterior Lighting Total 2553.00           40.11



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:12

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
None          


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
SPLIT GSW COOLING COIL Coil:Cooling:DX:SingleSpeed   3368.49 2690.27 678.23 0.80 3.91    
SPLIT GNW COOLING COIL Coil:Cooling:DX:SingleSpeed   3325.89 2656.24 669.65 0.80 3.91    
SPLIT OFFICE COOLING COIL Coil:Cooling:DX:SingleSpeed   9057.32 7233.67 1823.64 0.80 3.91    
SPLIT GNE COOLING COIL Coil:Cooling:DX:SingleSpeed   2450.59 1957.18 493.41 0.80 3.91    
SPLIT GN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   1911.29 1526.46 384.83 0.80 3.91    
SPLIT GN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   1890.11 1509.55 380.56 0.80 3.91    
SPLIT GS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   1909.42 1524.97 384.45 0.80 3.91    
SPLIT GS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   1967.40 1571.27 396.13 0.80 3.91    
SPLIT MSW COOLING COIL Coil:Cooling:DX:SingleSpeed   9050.38 7228.13 1822.25 0.80 3.91    
SPLIT MNW COOLING COIL Coil:Cooling:DX:SingleSpeed   8898.57 7106.89 1791.68 0.80 3.91    
SPLIT MSE COOLING COIL Coil:Cooling:DX:SingleSpeed   7678.31 6132.32 1545.99 0.80 3.91    
SPLIT MNE COOLING COIL Coil:Cooling:DX:SingleSpeed   6992.17 5584.34 1407.84 0.80 3.91    
SPLIT MN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   5342.45 4266.78 1075.67 0.80 3.91    
SPLIT MN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   5307.36 4238.75 1068.61 0.80 3.91    
SPLIT MS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   5473.34 4371.31 1102.03 0.80 3.91    
SPLIT MS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   5493.45 4387.38 1106.08 0.80 3.91    
SPLIT TSW COOLING COIL Coil:Cooling:DX:SingleSpeed   6258.47 4998.36 1260.11 0.80 3.91    
SPLIT TNW COOLING COIL Coil:Cooling:DX:SingleSpeed   6052.20 4833.62 1218.58 0.80 3.91    
SPLIT TSE COOLING COIL Coil:Cooling:DX:SingleSpeed   5598.59 4471.34 1127.25 0.80 3.91    
SPLIT TNE COOLING COIL Coil:Cooling:DX:SingleSpeed   5022.19 4011.00 1011.19 0.80 3.91    
SPLIT TN1 COOLING COIL Coil:Cooling:DX:SingleSpeed   3915.49 3127.12 788.36 0.80 3.91    
SPLIT TN2 COOLING COIL Coil:Cooling:DX:SingleSpeed   3917.43 3128.67 788.75 0.80 3.91    
SPLIT TS1 COOLING COIL Coil:Cooling:DX:SingleSpeed   4452.89 3556.32 896.57 0.80 3.91    
SPLIT TS2 COOLING COIL Coil:Cooling:DX:SingleSpeed   4464.02 3565.21 898.81 0.80 3.91    


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER [Btu/W-h] IEER [Btu/W-h]
SPLIT GSW COOLING COIL Coil:Cooling:DX:SingleSpeed 3209.0 3.13 10.67 11.09 10.38
SPLIT GNW COOLING COIL Coil:Cooling:DX:SingleSpeed 3168.4 3.13 10.67 11.09 10.38
SPLIT OFFICE COOLING COIL Coil:Cooling:DX:SingleSpeed 8628.5 3.13 10.67 11.09 10.38
SPLIT GNE COOLING COIL Coil:Cooling:DX:SingleSpeed 2334.6 3.13 10.67 11.09 10.38
SPLIT GN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 1820.8 3.13 10.67 11.09 10.38
SPLIT GN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 1800.6 3.13 10.67 11.09 10.38
SPLIT GS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 1819.0 3.13 10.67 11.09 10.38
SPLIT GS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 1874.3 3.13 10.67 11.09 10.38
SPLIT MSW COOLING COIL Coil:Cooling:DX:SingleSpeed 8621.9 3.13 10.67 11.09 10.38
SPLIT MNW COOLING COIL Coil:Cooling:DX:SingleSpeed 8477.3 3.13 10.67 11.09 10.38
SPLIT MSE COOLING COIL Coil:Cooling:DX:SingleSpeed 7314.8 3.13 10.67 11.09 10.38
SPLIT MNE COOLING COIL Coil:Cooling:DX:SingleSpeed 6661.1 3.13 10.67 11.09 10.38
SPLIT MN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 5089.5 3.13 10.67 11.09 10.38
SPLIT MN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 5056.1 3.13 10.67 11.09 10.38
SPLIT MS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 5214.2 3.13 10.67 11.09 10.38
SPLIT MS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 5233.4 3.13 10.67 11.09 10.38
SPLIT TSW COOLING COIL Coil:Cooling:DX:SingleSpeed 5962.2 3.13 10.67 11.09 10.38
SPLIT TNW COOLING COIL Coil:Cooling:DX:SingleSpeed 5765.7 3.13 10.67 11.09 10.38
SPLIT TSE COOLING COIL Coil:Cooling:DX:SingleSpeed 5333.5 3.13 10.67 11.09 10.38
SPLIT TNE COOLING COIL Coil:Cooling:DX:SingleSpeed 4784.4 3.13 10.67 11.09 10.38
SPLIT TN1 COOLING COIL Coil:Cooling:DX:SingleSpeed 3730.1 3.13 10.67 11.09 10.38
SPLIT TN2 COOLING COIL Coil:Cooling:DX:SingleSpeed 3732.0 3.13 10.67 11.09 10.38
SPLIT TS1 COOLING COIL Coil:Cooling:DX:SingleSpeed 4242.1 3.13 10.67 11.09 10.38
SPLIT TS2 COOLING COIL Coil:Cooling:DX:SingleSpeed 4252.7 3.13 10.67 11.09 10.38
ANSI/AHRI ratings include supply fan

DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
SPLIT GSW HEATING COIL Coil:Heating:Gas   2219.07 0.80
SPLIT GNW HEATING COIL Coil:Heating:Gas   2201.53 0.80
SPLIT OFFICE HEATING COIL Coil:Heating:Gas   4091.08 0.80
SPLIT GNE HEATING COIL Coil:Heating:Gas   2201.53 0.80
SPLIT GN1 HEATING COIL Coil:Heating:Gas   1610.17 0.80
SPLIT GN2 HEATING COIL Coil:Heating:Gas   1610.17 0.80
SPLIT GS1 HEATING COIL Coil:Heating:Gas   1601.92 0.80
SPLIT GS2 HEATING COIL Coil:Heating:Gas   1701.15 0.80
SPLIT MSW HEATING COIL Coil:Heating:Gas   4382.89 0.80
SPLIT MNW HEATING COIL Coil:Heating:Gas   4407.95 0.80
SPLIT MSE HEATING COIL Coil:Heating:Gas   4382.89 0.80
SPLIT MNE HEATING COIL Coil:Heating:Gas   4407.95 0.80
SPLIT MN1 HEATING COIL Coil:Heating:Gas   2990.99 0.80
SPLIT MN2 HEATING COIL Coil:Heating:Gas   2990.99 0.80
SPLIT MS1 HEATING COIL Coil:Heating:Gas   2990.99 0.80
SPLIT MS2 HEATING COIL Coil:Heating:Gas   2990.99 0.80
SPLIT TSW HEATING COIL Coil:Heating:Gas   3428.01 0.80
SPLIT TNW HEATING COIL Coil:Heating:Gas   3442.67 0.80
SPLIT TSE HEATING COIL Coil:Heating:Gas   3428.01 0.80
SPLIT TNE HEATING COIL Coil:Heating:Gas   3442.67 0.80
SPLIT TN1 HEATING COIL Coil:Heating:Gas   2638.78 0.80
SPLIT TN2 HEATING COIL Coil:Heating:Gas   2638.78 0.80
SPLIT TS1 HEATING COIL Coil:Heating:Gas   2622.14 0.80
SPLIT TS2 HEATING COIL Coil:Heating:Gas   2622.14 0.80


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electric Power [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction End Use
SPLIT GSW SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 236.22 1160.84 1.00 General
SPLIT GNW SUPPLY FAN Fan:OnOff 0.54 622.50 0.20 233.23 1160.84 1.00 General
SPLIT OFFICE SUPPLY FAN Fan:OnOff 0.54 622.50 0.55 635.16 1160.84 1.00 General
SPLIT GNE SUPPLY FAN Fan:OnOff 0.54 622.50 0.15 171.85 1160.84 1.00 General
SPLIT GN1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 134.03 1160.84 1.00 General
SPLIT GN2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.11 132.55 1160.84 1.00 General
SPLIT GS1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 133.90 1160.84 1.00 General
SPLIT GS2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.12 137.97 1160.84 1.00 General
SPLIT MSW SUPPLY FAN Fan:OnOff 0.54 622.50 0.55 634.67 1160.84 1.00 General
SPLIT MNW SUPPLY FAN Fan:OnOff 0.54 622.50 0.54 624.02 1160.84 1.00 General
SPLIT MSE SUPPLY FAN Fan:OnOff 0.54 622.50 0.46 538.45 1160.84 1.00 General
SPLIT MNE SUPPLY FAN Fan:OnOff 0.54 622.50 0.42 490.34 1160.84 1.00 General
SPLIT MN1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 374.65 1160.84 1.00 General
SPLIT MN2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.32 372.19 1160.84 1.00 General
SPLIT MS1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.33 383.83 1160.84 1.00 General
SPLIT MS2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.33 385.24 1160.84 1.00 General
SPLIT TSW SUPPLY FAN Fan:OnOff 0.54 622.50 0.38 438.88 1160.84 1.00 General
SPLIT TNW SUPPLY FAN Fan:OnOff 0.54 622.50 0.37 424.42 1160.84 1.00 General
SPLIT TSE SUPPLY FAN Fan:OnOff 0.54 622.50 0.34 392.61 1160.84 1.00 General
SPLIT TNE SUPPLY FAN Fan:OnOff 0.54 622.50 0.30 352.19 1160.84 1.00 General
SPLIT TN1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 274.58 1160.84 1.00 General
SPLIT TN2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.24 274.71 1160.84 1.00 General
SPLIT TS1 SUPPLY FAN Fan:OnOff 0.54 622.50 0.27 312.26 1160.84 1.00 General
SPLIT TS2 SUPPLY FAN Fan:OnOff 0.54 622.50 0.27 313.05 1160.84 1.00 General


Pumps

Type Control Head [pa] Water Flow [m3/s] Electric Power [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W]
None              


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
G SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
G S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M SE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
M S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T SW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T NW APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T SE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T NE APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T N1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T N2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T S1 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90
T S2 APARTMENT WATER HEATER WaterHeater:Mixed 0.19 14653.55 1.00 3.78 0.90



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:12

Zone Cooling

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1781.16 2137.39 0.170 0.203 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 32.87 0.00565
G NW APARTMENT 1758.61 2110.33 0.167 0.201 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 18:00:00 31.86 0.00565
OFFICE 4559.06 5470.87 0.456 0.547 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 09:30:00 28.82 0.00565
G NE APARTMENT 1295.80 1554.96 0.123 0.148 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 30.98 0.00565
G N1 APARTMENT 1010.61 1212.73 0.096 0.115 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 30.85 0.00565
G N2 APARTMENT 999.41 1199.29 0.095 0.114 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 30.85 0.00565
G S1 APARTMENT 1009.63 1211.56 0.096 0.115 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 35.10 0.00565
G S2 APARTMENT 1040.29 1248.35 0.099 0.119 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 34.93 0.00565
M SW APARTMENT 4785.61 5742.73 0.456 0.547 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 17:15:00 32.87 0.00565
M NW APARTMENT 4705.28 5646.34 0.448 0.538 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 17:45:00 32.20 0.00565
M SE APARTMENT 4060.13 4872.16 0.387 0.464 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 13:45:00 34.93 0.00565
M NE APARTMENT 3697.32 4436.78 0.352 0.422 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 10:45:00 31.49 0.00565
M N1 APARTMENT 2824.88 3389.85 0.269 0.323 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 18:30:00 30.85 0.00565
M N2 APARTMENT 2806.33 3367.59 0.267 0.321 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 18:15:00 31.35 0.00565
M S1 APARTMENT 2894.13 3472.95 0.276 0.331 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 35.10 0.00565
M S2 APARTMENT 2904.76 3485.72 0.277 0.332 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 35.10 0.00565
T SW APARTMENT 3309.42 3971.30 0.315 0.378 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 16:30:00 33.75 0.00565
T NW APARTMENT 3200.35 3840.42 0.305 0.366 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 17:00:00 33.21 0.00565
T SE APARTMENT 2960.48 3552.58 0.282 0.338 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 14:00:00 35.10 0.00565
T NE APARTMENT 2655.69 3186.82 0.253 0.303 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 14:30:00 35.10 0.00565
T N1 APARTMENT 2070.41 2484.49 0.197 0.237 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 15:15:00 34.90 0.00565
T N2 APARTMENT 2071.44 2485.73 0.197 0.237 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 14:45:00 35.10 0.00565
T S1 APARTMENT 2354.58 2825.49 0.224 0.269 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 35.10 0.00565
T S2 APARTMENT 2360.46 2832.56 0.225 0.270 ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB 7/21 14:15:00 35.10 0.00565


Zone Heating

Calculated Design Load [W] User Design Load [W] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak Temperature at Peak [C] Humidity Ratio at Peak [kgWater/kgAir]
G SW APARTMENT 1206.49 1447.79 0.042 0.051 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.90 0.00234
G NW APARTMENT 1215.21 1458.25 0.043 0.051 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.90 0.00234
OFFICE 2553.33 3064.00 0.086 0.103 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.90 0.00234
G NE APARTMENT 1215.21 1458.25 0.043 0.051 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.90 0.00234
G N1 APARTMENT 715.12 858.14 0.025 0.030 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.90 0.00234
G N2 APARTMENT 715.12 858.14 0.025 0.030 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.90 0.00234
G S1 APARTMENT 708.14 849.77 0.025 0.030 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.90 0.00234
G S2 APARTMENT 792.06 950.47 0.028 0.033 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 09:00:00 -7.90 0.00234
M SW APARTMENT 2413.44 2896.13 0.084 0.101 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -7.90 0.00234
M NW APARTMENT 2434.63 2921.55 0.085 0.102 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -7.90 0.00234
M SE APARTMENT 2413.44 2896.13 0.084 0.101 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -7.90 0.00234
M NE APARTMENT 2434.63 2921.55 0.085 0.102 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -7.90 0.00234
M N1 APARTMENT 1170.98 1405.17 0.041 0.052 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -7.90 0.00234
M N2 APARTMENT 1170.98 1405.17 0.041 0.052 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -7.90 0.00234
M S1 APARTMENT 1151.24 1381.48 0.040 0.052 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -7.90 0.00234
M S2 APARTMENT 1151.24 1381.48 0.040 0.052 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -7.90 0.00234
T SW APARTMENT 2252.44 2702.93 0.079 0.095 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -7.90 0.00234
T NW APARTMENT 2264.84 2717.81 0.079 0.095 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -7.90 0.00234
T SE APARTMENT 2252.44 2702.93 0.079 0.095 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -7.90 0.00234
T NE APARTMENT 2264.84 2717.81 0.079 0.095 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -7.90 0.00234
T N1 APARTMENT 1585.00 1902.00 0.055 0.067 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -7.90 0.00234
T N2 APARTMENT 1585.00 1902.00 0.055 0.067 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -7.90 0.00234
T S1 APARTMENT 1570.93 1885.11 0.055 0.066 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -7.90 0.00234
T S2 APARTMENT 1570.93 1885.11 0.055 0.066 ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB 12/21 04:00:00 -7.90 0.00234


System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s]
SPLIT GSW 0.20 0.20 0.05 0.05
SPLIT GNW 0.20 0.20 0.05 0.05
SPLIT OFFICE 0.55 0.55 0.10 0.10
SPLIT GNE 0.15 0.15 0.05 0.05
SPLIT GN1 0.12 0.12 0.03 0.03
SPLIT GN2 0.11 0.11 0.03 0.03
SPLIT GS1 0.12 0.12 0.03 0.03
SPLIT GS2 0.12 0.12 0.03 0.03
SPLIT MSW 0.55 0.55 0.10 0.10
SPLIT MNW 0.54 0.54 0.10 0.10
SPLIT MSE 0.46 0.46 0.10 0.10
SPLIT MNE 0.42 0.42 0.10 0.10
SPLIT MN1 0.32 0.32 0.05 0.05
SPLIT MN2 0.32 0.32 0.05 0.05
SPLIT MS1 0.33 0.33 0.05 0.05
SPLIT MS2 0.33 0.33 0.05 0.05
SPLIT TSW 0.38 0.38 0.09 0.09
SPLIT TNW 0.37 0.37 0.10 0.10
SPLIT TSE 0.34 0.34 0.09 0.09
SPLIT TNE 0.30 0.30 0.10 0.10
SPLIT TN1 0.24 0.24 0.07 0.07
SPLIT TN2 0.24 0.24 0.07 0.07
SPLIT TS1 0.27 0.27 0.07 0.07
SPLIT TS2 0.27 0.27 0.07 0.07



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:12

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule
None            


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
G SW APARTMENT 2275.75 5709.50 216.00
G NW APARTMENT 2721.25 5898.25 846.00
OFFICE 632.50 1382.25 2.75
G NE APARTMENT 2710.00 5891.00 810.75
G N1 APARTMENT 2007.50 6056.00 409.00
G N2 APARTMENT 2007.00 6055.50 408.00
G S1 APARTMENT 2002.00 5880.75 122.25
G S2 APARTMENT 2092.50 5810.00 98.00
M SW APARTMENT 2966.25 3395.25 5.50
M NW APARTMENT 2794.00 4574.00 34.00
M SE APARTMENT 2985.00 3373.50 4.50
M NE APARTMENT 2809.50 4534.00 34.25
M N1 APARTMENT 2571.00 4626.75 12.50
M N2 APARTMENT 2573.00 4629.75 12.50
M S1 APARTMENT 2810.75 3035.00 10.00
M S2 APARTMENT 2813.75 3037.50 9.75
T SW APARTMENT 3468.75 4152.50 551.25
T NW APARTMENT 3887.50 4944.75 1261.50
T SE APARTMENT 3476.00 4101.75 566.25
T NE APARTMENT 3869.75 4963.50 1246.75
T N1 APARTMENT 3428.75 5054.25 924.00
T N2 APARTMENT 3435.50 5051.00 928.25
T S1 APARTMENT 2992.00 4116.50 259.75
T S2 APARTMENT 2995.75 4108.00 261.75
T CORRIDOR 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00
Facility 4926.00 6139.50 1544.75
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
G SW APARTMENT 5.25 0.25 5.25 0.25
G NW APARTMENT 2.25 0.00 2.25 0.00
OFFICE 1.25 14.50 0.00 0.00
G NE APARTMENT 3.25 0.00 3.25 0.00
G N1 APARTMENT 8.75 0.00 8.75 0.00
G N2 APARTMENT 8.75 0.00 8.75 0.00
G S1 APARTMENT 2.25 0.25 2.25 0.25
G S2 APARTMENT 2.25 0.00 2.25 0.00
M SW APARTMENT 0.25 0.00 0.25 0.00
M NW APARTMENT 0.75 0.00 0.75 0.00
M SE APARTMENT 2.00 0.00 2.00 0.00
M NE APARTMENT 0.25 0.00 0.25 0.00
M N1 APARTMENT 0.50 0.00 0.50 0.00
M N2 APARTMENT 1.00 0.00 1.00 0.00
M S1 APARTMENT 0.00 0.00 0.00 0.00
M S2 APARTMENT 0.00 0.00 0.00 0.00
T SW APARTMENT 0.00 0.25 0.00 0.25
T NW APARTMENT 0.00 1.25 0.00 1.25
T SE APARTMENT 0.00 0.00 0.00 0.00
T NE APARTMENT 0.00 0.25 0.00 0.25
T N1 APARTMENT 0.25 0.00 0.25 0.00
T N2 APARTMENT 0.25 0.00 0.25 0.00
T S1 APARTMENT 0.75 0.00 0.75 0.00
T S2 APARTMENT 0.25 0.00 0.25 0.00
T CORRIDOR 0.00 0.00 0.00 0.00
G CORRIDOR 0.00 0.00 0.00 0.00
M CORRIDOR 0.00 0.00 0.00 0.00
Facility 37.00 16.75 35.75 2.25
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:12

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.97 0.364 0.174 0.000 0.081
G NW APARTMENT 1.71 2.50 268.97 0.351 0.174 0.000 0.077
OFFICE 0.94 1.00 268.97 0.517 0.180 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.351 0.174 0.000 0.077
G N1 APARTMENT 1.71 2.50 268.97 0.351 0.105 0.000 0.076
G N2 APARTMENT 1.71 2.50 268.97 0.351 0.105 0.000 0.076
G S1 APARTMENT 1.71 2.50 268.97 0.352 0.105 0.000 0.080
G S2 APARTMENT 1.71 2.50 268.97 0.352 0.105 0.000 0.080
M SW APARTMENT 1.71 2.50 268.97 0.352 0.250 0.000 0.100
M NW APARTMENT 1.71 2.50 268.97 0.352 0.250 0.000 0.096
M SE APARTMENT 1.71 2.50 268.97 0.352 0.250 0.000 0.100
M NE APARTMENT 1.71 2.50 268.97 0.352 0.250 0.000 0.096
M N1 APARTMENT 1.71 2.50 268.97 0.352 0.151 0.000 0.095
M N2 APARTMENT 1.71 2.50 268.97 0.352 0.151 0.000 0.095
M S1 APARTMENT 1.71 2.50 268.97 0.353 0.151 0.000 0.100
M S2 APARTMENT 1.71 2.50 268.97 0.353 0.151 0.000 0.100
T SW APARTMENT 1.71 2.50 268.97 0.352 0.331 0.000 0.122
T NW APARTMENT 1.71 2.50 268.97 0.352 0.331 0.000 0.116
T SE APARTMENT 1.71 2.50 268.97 0.352 0.331 0.000 0.122
T NE APARTMENT 1.71 2.50 268.97 0.352 0.331 0.000 0.116
T N1 APARTMENT 1.71 2.50 268.97 0.352 0.199 0.000 0.115
T N2 APARTMENT 1.71 2.50 268.97 0.352 0.199 0.000 0.115
T S1 APARTMENT 1.71 2.50 268.97 0.352 0.200 0.000 0.122
T S2 APARTMENT 1.71 2.50 268.97 0.352 0.200 0.000 0.122
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
G SW APARTMENT 1.71 2.50 268.97 0.355 0.000 0.000 0.000
G NW APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
OFFICE 0.94 1.00 268.97 0.502 0.000 0.000 0.000
G NE APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
G N1 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
G N2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
G S1 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
G S2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
M SW APARTMENT 1.71 2.50 268.97 1.370 0.000 0.000 0.000
M NW APARTMENT 1.71 2.50 268.97 1.367 0.000 0.000 0.000
M SE APARTMENT 1.71 2.50 268.97 1.370 0.000 0.000 0.000
M NE APARTMENT 1.71 2.50 268.97 1.367 0.000 0.000 0.000
M N1 APARTMENT 1.71 2.50 268.97 1.367 0.000 0.000 0.000
M N2 APARTMENT 1.71 2.50 268.97 1.367 0.000 0.000 0.000
M S1 APARTMENT 1.71 2.50 268.97 1.373 0.000 0.000 0.000
M S2 APARTMENT 1.71 2.50 268.97 1.373 0.000 0.000 0.000
T SW APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
T NW APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
T SE APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
T NE APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
T N1 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
T N2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
T S1 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
T S2 APARTMENT 1.71 2.50 268.97 0.342 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:12

Surfaces by Class

Total Outdoors
Wall 126 42
Floor 27 9
Roof 27 9
Internal Mass 24 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 39 39
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 24
Conditioned Zones 24
Unconditioned Zones 3
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 1385
Defaulted Fields 439
Fields with Defaults 3704
Autosized Fields 336
Autosizable Fields 454
Autocalculated Fields 247
Autocalculatable Fields 424



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2015-09-09 18:47:12

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum Electricity Maximum Value [W] Timestamp of Maximum
Electricity:Facility 1472.01 21513.59 01-JAN-03:15 82340.84 21-JUL-17:30
Electricity:Building 636.11 10559.61 01-JAN-03:15 31610.87 01-JAN-18:15
Electricity:Zone:G SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity 118.46 2466.75 01-JAN-00:15 5482.59 01-JAN-19:15
InteriorLights:Electricity:Zone:G SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
GeneralLights:InteriorLights:Electricity 96.36 2205.67 01-JAN-00:15 4426.44 01-JAN-19:15
Electricity:Zone:G NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:OFFICE 35.93 610.39 01-JAN-00:15 2669.36 02-JAN-08:15
InteriorLights:Electricity:Zone:OFFICE 26.45 416.15 01-JAN-00:15 2080.74 02-JAN-08:15
Electricity:Zone:G NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:G S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:M SW APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M SW APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M NW APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M NW APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M SE APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M SE APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M NE APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M NE APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M N1 APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M N1 APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M N2 APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M N2 APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M S1 APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M S1 APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:M S2 APARTMENT 26.60 460.32 01-JAN-03:15 1352.36 01-JAN-18:15
InteriorLights:Electricity:Zone:M S2 APARTMENT 2.17 12.97 01-JAN-00:15 207.54 01-JAN-19:15
Electricity:Zone:T SW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NW APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NW APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T SE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T SE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T NE APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T NE APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T N2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T N2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S1 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S1 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:T S2 APARTMENT 13.30 230.16 01-JAN-03:15 676.18 01-JAN-18:15
InteriorLights:Electricity:Zone:T S2 APARTMENT 1.09 6.49 01-JAN-00:15 103.77 01-JAN-19:15
Electricity:Zone:G CORRIDOR 144.16 1427.03 01-JAN-00:15 8651.76 01-JAN-07:15
InteriorLights:Electricity:Zone:G CORRIDOR 14.58 462.39 01-JAN-00:15 462.39 01-JAN-00:15
Electricity:Zone:M CORRIDOR 29.16 924.77 01-JAN-00:15 924.77 01-JAN-00:15
InteriorLights:Electricity:Zone:M CORRIDOR 29.16 924.77 01-JAN-00:15 924.77 01-JAN-00:15
Electricity:Zone:T CORRIDOR 14.58 462.39 01-JAN-00:15 462.39 01-JAN-00:15
InteriorLights:Electricity:Zone:T CORRIDOR 14.58 462.39 01-JAN-00:15 462.39 01-JAN-00:15
GeneralLights-plugin:InteriorLights:Electricity 22.11 261.08 01-JAN-00:15 1411.40 02-JAN-16:15
InteriorEquipment:Electricity 517.65 8092.87 01-JAN-03:15 26730.99 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
MiscPlug:InteriorEquipment:Electricity 517.65 8092.87 01-JAN-03:15 26730.99 02-JAN-17:15
InteriorEquipment:Electricity:Zone:G NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:OFFICE 9.48 194.25 01-JAN-00:15 588.62 02-JAN-08:15
InteriorEquipment:Electricity:Zone:G NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SW APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NW APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M SE APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M NE APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N1 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M N2 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S1 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:M S2 APARTMENT 24.43 447.35 01-JAN-03:15 1177.25 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NW APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T SE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T NE APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T N2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S1 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:T S2 APARTMENT 12.21 223.68 01-JAN-03:15 588.62 01-JAN-17:15
InteriorEquipment:Electricity:Zone:G CORRIDOR 129.57 964.65 01-JAN-00:15 8189.37 01-JAN-07:15
Electricity:Plant 383.84 0.00 01-JAN-00:15 32341.56 01-JAN-08:30
WaterSystems:Electricity 383.84 0.00 01-JAN-00:15 32341.56 01-JAN-08:30
Water Heater:WaterSystems:Electricity 383.84 0.00 01-JAN-00:15 32341.56 01-JAN-08:30
Fans:Electricity 264.93 8400.98 03-JAN-08:30 8400.98 01-JAN-00:15
Fans:Electricity:Zone:G SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Ventilation (simple):Fans:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:G S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:M S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NW APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T SE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T NE APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T N2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S1 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Fans:Electricity:Zone:T S2 APARTMENT 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityPurchased:Facility 1472.01 21513.59 01-JAN-03:15 82340.84 21-JUL-17:30
ElectricityPurchased:Plant 1472.01 21513.59 01-JAN-03:15 82340.84 21-JUL-17:30
Cogeneration:ElectricityPurchased 1472.01 21513.59 01-JAN-03:15 82340.84 21-JUL-17:30
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
ElectricityNet:Facility 1472.01 21513.59 01-JAN-03:15 82340.84 21-JUL-17:30
ElectricityNet:Plant 1472.01 21513.59 01-JAN-03:15 82340.84 21-JUL-17:30
Cogeneration:ElectricityNet 1472.01 21513.59 01-JAN-03:15 82340.84 21-JUL-17:30
ExteriorLights:Electricity 40.11 0.00 01-JAN-07:30 2553.00 01-JAN-00:15
General:ExteriorLights:Electricity 40.11 0.00 01-JAN-07:30 2553.00 01-JAN-00:15
Electricity:HVAC 411.94 8400.98 14-JAN-08:30 32888.06 29-JUN-15:00
General:Fans:Electricity 264.93 8400.98 03-JAN-08:30 8400.98 01-JAN-00:15
Heating:Electricity 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:Electricity 147.01 0.00 01-JAN-00:15 24487.08 29-JUN-15:00


Annual and Peak Values - Gas

Gas Annual Value [GJ] Gas Minimum Value [W] Timestamp of Minimum Gas Maximum Value [W] Timestamp of Maximum
Gas:Facility 127.18 0.00 01-JAN-13:30 60925.70 18-JAN-01:15
Gas:HVAC 127.18 0.00 01-JAN-13:30 60925.70 18-JAN-01:15
Heating:Gas 127.18 0.00 01-JAN-13:30 60925.70 18-JAN-01:15


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum Cooling Maximum Value [W] Timestamp of Maximum
None          


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
Water:Facility 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water:Plant 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
WaterSystems:Water 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:Water 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
MainsWater:Facility 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
MainsWater:Plant 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
WaterSystems:MainsWater 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15
Water Heater:WaterSystems:MainsWater 1874.72 0.00 01-JAN-02:15 0.00 01-JAN-07:15


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum Maximum Value [kg/s] Timestamp of Maximum
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:15 0.000 01-JAN-00:15


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum Maximum Value [m3/s] Timestamp of Maximum
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum Maximum Value [L] Timestamp of Maximum
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum Maximum Value [W] Timestamp of Maximum
PlantLoopHeatingDemand:Facility 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
PlantLoopHeatingDemand:Plant 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Facility 1239.99 2071.80 21-MAY-06:00 151467.70 29-JUN-15:15
EnergyTransfer:Building 567.32 2071.80 21-MAY-06:00 66091.79 29-JUN-15:15
EnergyTransfer:Zone:G SW APARTMENT 11.46 0.00 18-MAY-02:45 2122.03 04-JUL-17:00
Heating:EnergyTransfer 65.17 0.00 03-JAN-20:15 39688.69 14-DEC-04:00
Heating:EnergyTransfer:Zone:G SW APARTMENT 1.90 0.00 01-JAN-08:30 1297.17 14-DEC-04:00
Cooling:EnergyTransfer 502.15 0.00 17-JAN-07:15 66091.79 29-JUN-15:15
Cooling:EnergyTransfer:Zone:G SW APARTMENT 9.56 0.00 01-JAN-00:15 2122.03 04-JUL-17:00
EnergyTransfer:Zone:G NW APARTMENT 10.89 0.00 30-APR-03:15 2150.78 04-JUL-17:15
Heating:EnergyTransfer:Zone:G NW APARTMENT 3.97 0.00 01-JAN-16:30 1569.43 14-DEC-04:00
Cooling:EnergyTransfer:Zone:G NW APARTMENT 6.92 0.00 01-JAN-00:15 2150.78 04-JUL-17:15
EnergyTransfer:Zone:OFFICE 27.40 0.02 16-NOV-19:30 4559.25 20-AUG-11:00
Heating:EnergyTransfer:Zone:OFFICE 4.32 0.00 01-JAN-00:15 1674.69 17-JAN-07:15
Cooling:EnergyTransfer:Zone:OFFICE 23.08 0.00 01-JAN-11:45 4559.25 20-AUG-11:00
EnergyTransfer:Zone:G NE APARTMENT 11.09 0.01 14-JAN-16:30 1583.85 14-DEC-04:00
Heating:EnergyTransfer:Zone:G NE APARTMENT 3.69 0.00 01-JAN-10:15 1583.85 14-DEC-04:00
Cooling:EnergyTransfer:Zone:G NE APARTMENT 7.40 0.00 01-JAN-00:15 1541.54 04-JUL-17:15
EnergyTransfer:Zone:G N1 APARTMENT 7.43 0.01 22-MAY-02:30 1167.74 04-JUL-17:30
Heating:EnergyTransfer:Zone:G N1 APARTMENT 1.72 0.00 01-JAN-11:30 899.62 14-DEC-04:00
Cooling:EnergyTransfer:Zone:G N1 APARTMENT 5.71 0.00 01-JAN-00:15 1167.74 04-JUL-17:30
EnergyTransfer:Zone:G N2 APARTMENT 7.45 0.00 02-OCT-01:15 1155.28 04-JUL-17:30
Heating:EnergyTransfer:Zone:G N2 APARTMENT 1.72 0.00 01-JAN-11:15 900.94 14-DEC-04:00
Cooling:EnergyTransfer:Zone:G N2 APARTMENT 5.73 0.00 01-JAN-00:15 1155.28 04-JUL-17:30
EnergyTransfer:Zone:G S1 APARTMENT 9.35 0.01 20-APR-15:45 1400.66 21-SEP-13:30
Heating:EnergyTransfer:Zone:G S1 APARTMENT 0.49 0.00 01-JAN-00:15 691.07 18-JAN-01:15
Cooling:EnergyTransfer:Zone:G S1 APARTMENT 8.86 0.00 01-JAN-02:00 1400.66 21-SEP-13:30
EnergyTransfer:Zone:G S2 APARTMENT 9.84 0.01 10-MAY-09:30 1472.41 03-SEP-13:30
Heating:EnergyTransfer:Zone:G S2 APARTMENT 0.51 0.00 01-JAN-00:15 716.16 18-JAN-01:15
Cooling:EnergyTransfer:Zone:G S2 APARTMENT 9.33 0.00 01-JAN-02:15 1472.41 03-SEP-13:30
EnergyTransfer:Zone:M SW APARTMENT 44.53 0.17 24-OCT-09:00 5616.29 04-JUL-17:00
Heating:EnergyTransfer:Zone:M SW APARTMENT 0.45 0.00 01-JAN-00:15 2415.69 18-JAN-01:15
Cooling:EnergyTransfer:Zone:M SW APARTMENT 44.08 0.00 11-JAN-05:15 5616.29 04-JUL-17:00
EnergyTransfer:Zone:M NW APARTMENT 32.81 0.01 04-MAR-14:45 5629.01 04-JUL-17:15
Heating:EnergyTransfer:Zone:M NW APARTMENT 3.07 0.00 01-JAN-08:30 3525.77 14-DEC-04:00
Cooling:EnergyTransfer:Zone:M NW APARTMENT 29.74 0.00 01-JAN-00:15 5629.01 04-JUL-17:15
EnergyTransfer:Zone:M SE APARTMENT 46.43 0.00 02-JUN-03:30 4784.89 03-SEP-13:30
Heating:EnergyTransfer:Zone:M SE APARTMENT 0.49 0.00 01-JAN-00:15 2443.15 18-JAN-01:15
Cooling:EnergyTransfer:Zone:M SE APARTMENT 45.94 0.00 11-JAN-05:00 4784.89 03-SEP-13:30
EnergyTransfer:Zone:M NE APARTMENT 34.85 0.08 10-FEB-15:00 4339.00 04-JUL-17:00
Heating:EnergyTransfer:Zone:M NE APARTMENT 3.06 0.00 01-JAN-07:45 3597.51 14-DEC-04:00
Cooling:EnergyTransfer:Zone:M NE APARTMENT 31.79 0.00 01-JAN-00:15 4339.00 04-JUL-17:00
EnergyTransfer:Zone:M N1 APARTMENT 27.95 0.14 15-FEB-15:30 3210.06 04-JUL-17:15
Heating:EnergyTransfer:Zone:M N1 APARTMENT 0.55 0.00 01-JAN-00:15 1800.97 14-DEC-04:00
Cooling:EnergyTransfer:Zone:M N1 APARTMENT 27.40 0.00 01-JAN-02:45 3210.06 04-JUL-17:15
EnergyTransfer:Zone:M N2 APARTMENT 27.99 0.06 31-OCT-11:45 3192.03 04-JUL-17:15
Heating:EnergyTransfer:Zone:M N2 APARTMENT 0.56 0.00 01-JAN-00:15 1810.30 14-DEC-04:00
Cooling:EnergyTransfer:Zone:M N2 APARTMENT 27.44 0.00 01-JAN-02:45 3192.03 04-JUL-17:15
EnergyTransfer:Zone:M S1 APARTMENT 43.28 0.13 03-MAY-12:00 4137.77 11-OCT-12:45
Heating:EnergyTransfer:Zone:M S1 APARTMENT 0.03 0.00 01-JAN-00:15 974.68 18-JAN-01:15
Cooling:EnergyTransfer:Zone:M S1 APARTMENT 43.25 0.00 17-JAN-02:00 4137.77 11-OCT-12:45
EnergyTransfer:Zone:M S2 APARTMENT 43.31 0.38 03-MAY-17:15 4144.40 11-OCT-12:45
Heating:EnergyTransfer:Zone:M S2 APARTMENT 0.03 0.00 01-JAN-00:15 978.47 18-JAN-01:15
Cooling:EnergyTransfer:Zone:M S2 APARTMENT 43.28 0.00 17-JAN-02:00 4144.40 11-OCT-12:45
EnergyTransfer:Zone:T SW APARTMENT 25.45 0.02 22-FEB-18:45 3812.88 04-JUL-17:00
Heating:EnergyTransfer:Zone:T SW APARTMENT 5.06 0.00 01-JAN-08:45 2645.50 14-DEC-04:00
Cooling:EnergyTransfer:Zone:T SW APARTMENT 20.38 0.00 01-JAN-00:15 3812.88 04-JUL-17:00
EnergyTransfer:Zone:T NW APARTMENT 23.17 0.00 06-FEB-15:30 3820.00 04-JUL-17:00
Heating:EnergyTransfer:Zone:T NW APARTMENT 8.19 0.00 03-JAN-20:15 3061.44 14-DEC-04:00
Cooling:EnergyTransfer:Zone:T NW APARTMENT 14.98 0.00 01-JAN-00:15 3820.00 04-JUL-17:00
EnergyTransfer:Zone:T SE APARTMENT 25.67 0.00 14-NOV-23:15 3370.23 03-SEP-13:30
Heating:EnergyTransfer:Zone:T SE APARTMENT 4.82 0.00 01-JAN-08:15 2669.02 14-DEC-04:00
Cooling:EnergyTransfer:Zone:T SE APARTMENT 20.84 0.00 01-JAN-00:15 3370.23 03-SEP-13:30
EnergyTransfer:Zone:T NE APARTMENT 23.11 0.00 09-OCT-03:45 3124.33 29-JUN-15:00
Heating:EnergyTransfer:Zone:T NE APARTMENT 7.72 0.00 01-JAN-10:15 3094.59 14-DEC-04:00
Cooling:EnergyTransfer:Zone:T NE APARTMENT 15.39 0.00 01-JAN-00:15 3124.33 29-JUN-15:00
EnergyTransfer:Zone:T N1 APARTMENT 16.64 0.01 11-FEB-14:00 2411.14 29-JUN-15:15
Heating:EnergyTransfer:Zone:T N1 APARTMENT 4.35 0.00 01-JAN-10:45 1926.55 14-DEC-04:00
Cooling:EnergyTransfer:Zone:T N1 APARTMENT 12.29 0.00 01-JAN-00:15 2411.14 29-JUN-15:15
EnergyTransfer:Zone:T N2 APARTMENT 16.69 0.01 06-MAR-13:15 2406.82 29-JUN-15:15
Heating:EnergyTransfer:Zone:T N2 APARTMENT 4.37 0.00 01-JAN-10:45 1929.59 14-DEC-04:00
Cooling:EnergyTransfer:Zone:T N2 APARTMENT 12.32 0.00 01-JAN-00:15 2406.82 29-JUN-15:15
EnergyTransfer:Zone:T S1 APARTMENT 20.24 0.00 04-MAY-11:45 2821.24 03-SEP-13:30
Heating:EnergyTransfer:Zone:T S1 APARTMENT 2.04 0.00 01-JAN-00:15 1544.79 17-JAN-04:00
Cooling:EnergyTransfer:Zone:T S1 APARTMENT 18.20 0.00 01-JAN-01:30 2821.24 03-SEP-13:30
EnergyTransfer:Zone:T S2 APARTMENT 20.30 0.01 28-JAN-11:15 2829.37 03-SEP-13:30
Heating:EnergyTransfer:Zone:T S2 APARTMENT 2.05 0.00 01-JAN-00:15 1545.50 17-JAN-04:00
Cooling:EnergyTransfer:Zone:T S2 APARTMENT 18.25 0.00 01-JAN-01:30 2829.37 03-SEP-13:30
EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:T CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:G CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Heating:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
Cooling:EnergyTransfer:Zone:M CORRIDOR 0.00 0.00 01-JAN-00:15 0.00 01-JAN-00:15
EnergyTransfer:HVAC 672.67 0.00 15-APR-09:45 85428.94 29-JUN-15:00
HeatingCoils:EnergyTransfer 101.74 0.00 01-JAN-13:30 48740.56 18-JAN-01:15
CoolingCoils:EnergyTransfer 570.92 0.00 01-JAN-00:15 85428.94 29-JUN-15:00



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:12

Annual Building Sensible Heat Gain Components

HVAC Input Sensible Air Heating [GJ] HVAC Input Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
G SW APARTMENT 1.902 -9.558 0.000 0.000 3.782 1.087 12.213 18.728 0.000 0.330 0.000 0.000 -6.359 0.000 -4.605 -17.519
G NW APARTMENT 3.970 -6.916 0.000 0.000 3.819 1.087 12.213 9.451 0.000 0.328 0.000 0.000 -6.479 0.000 -4.433 -13.040
OFFICE 4.316 -23.082 0.000 0.000 0.518 26.452 9.482 18.946 0.000 0.190 0.001 0.000 -6.622 0.000 -4.295 -25.905
G NE APARTMENT 3.690 -7.399 0.000 0.000 3.831 1.087 12.213 9.829 0.000 0.328 0.000 0.000 -6.176 0.000 -4.410 -12.991
G N1 APARTMENT 1.720 -5.711 0.000 0.000 3.835 1.087 12.213 3.151 0.000 0.211 0.000 0.000 -3.975 0.000 -2.872 -9.658
G N2 APARTMENT 1.721 -5.728 0.000 0.000 3.835 1.087 12.213 3.150 0.000 0.211 0.000 0.000 -3.974 0.000 -2.872 -9.643
G S1 APARTMENT 0.489 -8.860 0.000 0.000 3.788 1.087 12.213 12.523 0.000 0.212 0.000 0.000 -3.841 0.000 -3.038 -14.571
G S2 APARTMENT 0.513 -9.329 0.000 0.000 3.784 1.087 12.213 12.513 0.000 0.212 0.000 0.000 -3.851 0.000 -3.049 -14.093
M SW APARTMENT 0.450 -44.080 0.000 0.000 3.628 1.087 12.213 18.187 0.000 0.468 22.021 0.000 -7.091 0.000 -6.884 0.000
M NW APARTMENT 3.067 -29.738 0.000 0.000 3.716 1.087 12.213 9.040 0.000 0.465 13.845 0.000 -7.089 0.000 -6.605 -0.001
M SE APARTMENT 0.491 -45.935 0.000 0.000 3.638 1.087 12.213 18.689 0.000 0.468 23.126 0.000 -6.906 0.000 -6.871 0.000
M NE APARTMENT 3.058 -31.788 0.000 0.000 3.729 1.087 12.213 9.397 0.000 0.465 15.160 0.000 -6.746 0.000 -6.575 -0.000
M N1 APARTMENT 0.552 -27.396 0.000 0.000 3.709 1.087 12.213 2.902 0.000 0.295 15.399 0.000 -4.420 0.000 -4.341 0.000
M N2 APARTMENT 0.556 -27.437 0.000 0.000 3.710 1.087 12.213 2.901 0.000 0.295 15.431 0.000 -4.417 0.000 -4.339 0.000
M S1 APARTMENT 0.031 -43.245 0.000 0.000 3.594 1.087 12.213 12.168 0.000 0.299 22.757 0.000 -4.332 0.000 -4.571 0.000
M S2 APARTMENT 0.030 -43.283 0.000 0.000 3.594 1.087 12.213 12.168 0.000 0.299 22.795 0.000 -4.331 0.000 -4.571 0.000
T SW APARTMENT 5.064 -20.381 0.000 0.000 3.722 1.087 12.213 18.058 0.000 0.625 0.000 0.000 -6.624 0.000 -8.663 -5.101
T NW APARTMENT 8.193 -14.980 0.000 0.000 3.765 1.087 12.213 8.927 0.000 0.619 0.000 0.000 -6.707 0.000 -8.414 -4.703
T SE APARTMENT 4.824 -20.843 0.000 0.000 3.729 1.087 12.213 18.566 0.000 0.625 0.000 0.000 -6.464 0.000 -8.663 -5.073
T NE APARTMENT 7.724 -15.390 0.000 0.000 3.777 1.087 12.213 9.319 0.000 0.619 0.000 0.000 -6.413 0.000 -8.389 -4.545
T N1 APARTMENT 4.350 -12.291 0.000 0.000 3.769 1.087 12.213 2.882 0.000 0.397 0.000 0.000 -4.147 0.000 -5.448 -2.812
T N2 APARTMENT 4.367 -12.322 0.000 0.000 3.769 1.087 12.213 2.879 0.000 0.397 0.000 0.000 -4.144 0.000 -5.450 -2.796
T S1 APARTMENT 2.042 -18.199 0.000 0.000 3.708 1.087 12.213 12.115 0.000 0.403 0.000 0.000 -4.042 0.000 -5.675 -3.650
T S2 APARTMENT 2.051 -18.251 0.000 0.000 3.708 1.087 12.213 12.112 0.000 0.403 0.000 0.000 -4.040 0.000 -5.676 -3.607
T CORRIDOR 0.000 0.000 0.000 0.000 0.000 14.582 0.000 0.178 0.000 0.039 0.000 0.000 -0.742 0.000 -1.436 -12.621
G CORRIDOR 0.000 0.000 0.000 0.000 0.000 14.582 6.479 0.628 0.000 1.168 0.607 0.000 -1.906 0.000 -21.557 -0.000
M CORRIDOR 0.000 0.000 0.000 0.000 0.000 14.582 0.000 0.180 0.000 0.036 0.000 0.000 -0.827 0.000 -1.195 -12.776
Total Facility 65.172 -502.143 0.000 0.000 86.457 95.189 296.854 259.585 0.000 10.409 151.143 0.000 -132.662 0.000 -154.897 -175.107


Peak Cooling Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 04-JUL-17:00 0.00 -2121.70 0.00 0.00 84.76 64.86 588.62 2096.96 0.00 316.40 0.00 0.00 0.00 0.00 0.00 -1029.89
G NW APARTMENT 04-JUL-17:05 0.00 -2151.85 0.00 0.00 141.81 87.56 588.62 2256.54 0.00 284.03 0.00 0.00 0.00 0.00 0.00 -1206.70
OFFICE 23-JUL-06:01 0.00 -8021.00 0.00 0.00 0.00 416.15 294.31 962.59 0.00 0.00 6361.98 0.00 0.00 0.00 -14.02 0.00
G NE APARTMENT 04-JUL-17:15 0.00 -1542.49 0.00 0.00 141.81 87.56 588.62 748.06 0.00 284.03 0.00 0.00 0.00 0.00 0.00 -307.59
G N1 APARTMENT 04-JUL-17:20 0.00 -1168.03 0.00 0.00 141.80 87.56 588.62 583.80 0.00 152.81 0.00 0.00 0.00 0.00 0.00 -386.56
G N2 APARTMENT 04-JUL-17:20 0.00 -1155.63 0.00 0.00 141.80 87.56 588.62 583.99 0.00 152.81 0.00 0.00 0.00 0.00 0.00 -399.14
G S1 APARTMENT 21-SEP-13:30 0.00 -1400.66 0.00 0.00 40.75 12.97 382.60 1936.97 0.00 22.87 0.00 0.00 0.00 0.00 0.00 -995.50
G S2 APARTMENT 03-SEP-13:30 0.00 -1472.41 0.00 0.00 40.75 12.97 382.60 1824.33 0.00 51.05 0.00 0.00 0.00 0.00 0.00 -839.30
M SW APARTMENT 04-JUL-17:00 0.00 -5615.56 0.00 0.00 84.76 64.86 588.62 2084.50 0.00 453.92 2338.91 0.00 0.00 0.00 0.00 0.00
M NW APARTMENT 04-JUL-17:05 0.00 -5630.84 0.00 0.00 141.81 87.56 588.62 2241.79 0.00 407.44 2163.62 0.00 0.00 0.00 0.00 0.00
M SE APARTMENT 03-SEP-13:30 0.00 -4784.86 0.00 0.00 40.75 12.97 382.60 2177.91 0.00 121.32 2049.32 0.00 0.00 0.00 0.00 0.00
M NE APARTMENT 04-JUL-17:00 0.00 -4338.53 0.00 0.00 84.76 64.86 588.62 731.57 0.00 453.91 2414.81 0.00 0.00 0.00 0.00 0.00
M N1 APARTMENT 04-JUL-17:08 0.00 -3211.30 0.00 0.00 141.81 87.56 588.62 541.76 0.00 245.76 1605.79 0.00 0.00 0.00 0.00 0.00
M N2 APARTMENT 04-JUL-17:05 0.00 -3194.73 0.00 0.00 141.81 87.56 588.62 541.87 0.00 245.76 1589.12 0.00 0.00 0.00 0.00 0.00
M S1 APARTMENT 11-OCT-12:45 0.00 -4135.31 0.00 0.00 40.75 12.97 388.49 2063.53 0.00 297.48 1332.09 0.00 0.00 0.00 0.00 0.00
M S2 APARTMENT 11-OCT-12:45 0.00 -4141.94 0.00 0.00 40.75 12.97 388.49 2063.49 0.00 297.48 1338.76 0.00 0.00 0.00 0.00 0.00
T SW APARTMENT 04-JUL-17:00 0.00 -3812.44 0.00 0.00 84.76 64.86 588.62 2047.95 0.00 598.34 427.91 0.00 0.00 0.00 0.00 0.00
T NW APARTMENT 04-JUL-17:00 0.00 -3819.57 0.00 0.00 84.76 64.86 588.62 2214.06 0.00 598.34 268.93 0.00 0.00 0.00 0.00 0.00
T SE APARTMENT 03-SEP-13:30 0.00 -3370.21 0.00 0.00 40.75 12.97 382.60 2138.29 0.00 159.62 635.97 0.00 0.00 0.00 0.00 0.00
T NE APARTMENT 29-JUN-15:00 0.00 -3123.10 0.00 0.00 40.75 22.70 400.26 1029.60 0.00 520.54 1109.25 0.00 0.00 0.00 0.00 0.00
T N1 APARTMENT 29-JUN-15:15 0.00 -2410.47 0.00 0.00 48.90 45.40 470.90 604.59 0.00 290.45 950.24 0.00 0.00 0.00 0.00 0.00
T N2 APARTMENT 29-JUN-15:15 0.00 -2406.16 0.00 0.00 48.90 45.40 470.90 604.63 0.00 290.45 945.88 0.00 0.00 0.00 0.00 0.00
T S1 APARTMENT 03-SEP-13:30 0.00 -2821.22 0.00 0.00 40.75 12.97 382.60 1787.12 0.00 96.28 501.49 0.00 0.00 0.00 0.00 0.00
T S2 APARTMENT 03-SEP-13:30 0.00 -2829.35 0.00 0.00 40.75 12.97 382.60 1786.99 0.00 96.28 509.75 0.00 0.00 0.00 0.00 0.00
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 29-JUN-15:15 0.00 -66073.49 0.00 0.00 1192.02 4512.09 11708.34 23558.88 0.00 7858.21 17243.96 0.00 0.00 0.00 0.00 0.00


Peak Heating Sensible Heat Gain Components

Time of Peak HVAC Input Sensible Air Heating [W] HVAC Input Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
G SW APARTMENT 14-DEC-04:00 1296.93 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 100.85 0.00 -641.64 0.00 -1175.98 0.00
G NW APARTMENT 14-DEC-04:00 1569.14 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 0.00 0.00 -641.17 0.00 -1175.98 -171.83
OFFICE 11-JAN-07:01 3784.87 0.00 0.00 0.00 0.00 416.15 294.31 0.00 0.00 0.00 0.00 0.00 -543.78 0.00 -475.41 -3476.13
G NE APARTMENT 14-DEC-04:00 1583.54 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 0.00 0.00 -632.12 0.00 -1175.98 -195.28
G N1 APARTMENT 16-FEB-07:01 987.44 0.00 0.00 0.00 163.19 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -290.09 0.00 -89.19 -1196.11
G N2 APARTMENT 07-DEC-17:01 1317.20 0.00 0.00 0.00 99.80 64.86 588.62 0.00 0.00 0.00 0.00 0.00 -260.75 0.00 -87.70 -1722.03
G S1 APARTMENT 19-FEB-07:01 1147.77 0.00 0.00 0.00 161.41 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -44.70 0.00 -132.44 -1556.80
G S2 APARTMENT 28-NOV-07:01 1210.14 0.00 0.00 0.00 161.42 42.16 382.60 501.23 0.00 0.00 0.00 0.00 0.00 0.00 -168.98 -2128.57
M SW APARTMENT 18-JAN-01:15 2415.46 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -660.57 0.00 -1115.07 -1077.32
M NW APARTMENT 14-DEC-04:00 3525.08 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 0.00 0.00 -665.61 0.00 -1691.45 -1587.86
M SE APARTMENT 18-JAN-01:15 2442.91 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -670.21 0.00 -1115.07 -1095.11
M NE APARTMENT 14-DEC-04:00 3596.75 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 0.00 0.00 -653.79 0.00 -1691.45 -1671.35
M N1 APARTMENT 14-DEC-04:00 1800.65 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 0.00 0.00 -404.96 0.00 -1020.24 -795.28
M N2 APARTMENT 09-JAN-07:01 2079.42 0.00 0.00 0.00 161.41 42.16 382.60 0.00 0.00 0.00 0.00 0.00 -406.04 0.00 -243.05 -2016.50
M S1 APARTMENT 18-JAN-01:15 974.59 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -409.55 0.00 -672.58 -329.95
M S2 APARTMENT 18-JAN-01:15 978.39 0.00 0.00 0.00 189.67 6.49 241.34 0.00 0.00 0.00 0.00 0.00 -409.51 0.00 -672.58 -333.79
T SW APARTMENT 14-DEC-04:00 2644.97 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 0.00 0.00 -644.65 0.00 -2241.15 -179.01
T NW APARTMENT 14-DEC-04:00 3060.83 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 0.00 0.00 -642.59 0.00 -2241.15 -596.93
T SE APARTMENT 14-DEC-04:00 2668.47 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 0.00 0.00 -633.75 0.00 -2241.15 -213.41
T NE APARTMENT 14-DEC-04:00 3093.94 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 0.00 0.00 -632.01 0.00 -2241.15 -640.61
T N1 APARTMENT 14-DEC-04:00 1926.19 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 0.00 0.00 -389.49 0.00 -1351.85 -604.69
T N2 APARTMENT 14-DEC-04:00 1929.24 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 0.00 0.00 -389.43 0.00 -1351.85 -607.80
T S1 APARTMENT 17-JAN-04:00 1544.77 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 0.00 0.00 -405.38 0.00 -898.58 -660.65
T S2 APARTMENT 17-JAN-04:00 1545.48 0.00 0.00 0.00 189.67 6.49 223.68 0.00 0.00 0.00 0.00 0.00 -405.37 0.00 -898.58 -661.37
T CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
G CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
M CORRIDOR - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 14-DEC-04:00 38087.63 0.00 0.00 0.00 4357.79 1952.47 5387.04 0.00 0.00 0.00 0.00 0.00 -12790.80 0.00 -33546.24 -3447.90



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:12

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA
None                    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA
None                    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None                    


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
None              


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
None            


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
None                          


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
None            



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:12

Sec1.1A-General Information

Data
Weather File Albuquerque Intl Arpt Isis NM USA TMY3 WMO#=723650
HDD and CDD data source Weather File Stat
Total gross floor area [m2] 3134.61
Principal Heating Source Natural Gas


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
G SW APARTMENT 88.25 88.25 0.00 168.00
G NW APARTMENT 88.25 88.25 0.00 168.00
OFFICE 88.25 88.25 0.00 43.32
G NE APARTMENT 88.25 88.25 0.00 168.00
G N1 APARTMENT 88.25 88.25 0.00 168.00
G N2 APARTMENT 88.25 88.25 0.00 168.00
G S1 APARTMENT 88.25 88.25 0.00 168.00
G S2 APARTMENT 88.25 88.25 0.00 168.00
M SW APARTMENT 88.25 88.25 0.00 168.00
M NW APARTMENT 88.25 88.25 0.00 168.00
M SE APARTMENT 88.25 88.25 0.00 168.00
M NE APARTMENT 88.25 88.25 0.00 168.00
M N1 APARTMENT 88.25 88.25 0.00 168.00
M N2 APARTMENT 88.25 88.25 0.00 168.00
M S1 APARTMENT 88.25 88.25 0.00 168.00
M S2 APARTMENT 88.25 88.25 0.00 168.00
T SW APARTMENT 88.25 88.25 0.00 168.00
T NW APARTMENT 88.25 88.25 0.00 168.00
T SE APARTMENT 88.25 88.25 0.00 168.00
T NE APARTMENT 88.25 88.25 0.00 168.00
T N1 APARTMENT 88.25 88.25 0.00 168.00
T N2 APARTMENT 88.25 88.25 0.00 168.00
T S1 APARTMENT 88.25 88.25 0.00 168.00
T S2 APARTMENT 88.25 88.25 0.00 168.00
T CORRIDOR 77.66 0.00 77.66 0.00
G CORRIDOR 77.66 0.00 77.66 0.00
M CORRIDOR 77.66 0.00 77.66 0.00
Totals 3134.61 2823.98 310.64  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 35.75
Number of hours cooling loads not met 2.25
Number of hours not met 38.00


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electric Energy Use [GJ] Electric Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Additional Energy Use [GJ] Additional Demand [W]
Interior Lighting 118.46 4979.95 0.00 0.00 0.00 0.00
Exterior Lighting 40.11 0.00 0.00 0.00 0.00 0.00
Space Heating 0.00 0.00 127.18 60925.70 0.00 0.00
Space Cooling 147.01 22755.18 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00
Fans-Interior 264.93 8400.98 0.00 0.00 0.00 0.00
Fans-Parking Garage 0.00 0.00 0.00 0.00 0.00 0.00
Service Water Heating 383.84 19573.81 0.00 0.00 0.00 0.00
Receptacle Equipment 517.65 26630.92 0.00 0.00 0.00 0.00
Interior Lighting (process) 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration Equipment 0.00 0.00 0.00 0.00 0.00 0.00
Cooking 0.00 0.00 0.00 0.00 0.00 0.00
Industrial Process 0.00 0.00 0.00 0.00 0.00 0.00
Elevators and Escalators 0.00 0.00 0.00 0.00 0.00 0.00
Total Line 1472.01   127.18   0.00  


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 517.65 1472.01
Natural Gas 0.00 127.18
Additional 0.00 0.00
Total 517.65 1599.19


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting 37.79
Space Heating 0.00
Space Cooling 46.90
Fans-Interior 84.52
Service Water Heating 122.45
Receptacle Equipment 165.14
Miscellaneous 12.80
Subtotal 469.60


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 40.57
Service Water Heating 0.00
Miscellaneous 0.00
Subtotal 40.57


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Miscellaneous 0.00
Subtotal 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting 7.41
Space Heating 7.95
Space Cooling 9.19
Fans-Interior 16.57
Service Water Heating 24.00
Receptacle Equipment 32.37
Miscellaneous 2.51



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:12

AirTerminal:SingleDuct:Uncontrolled

Maximum Air Flow Rate [m3/s]
G SW APARTMENT DIRECT AIR 0.203491
G NW APARTMENT DIRECT AIR 0.200917
OFFICE DIRECT AIR 0.547152
G NE APARTMENT DIRECT AIR 0.148040
G N1 APARTMENT DIRECT AIR 0.115461
G N2 APARTMENT DIRECT AIR 0.114182
G S1 APARTMENT DIRECT AIR 0.115348
G S2 APARTMENT DIRECT AIR 0.118851
M SW APARTMENT DIRECT AIR 0.546733
M NW APARTMENT DIRECT AIR 0.537562
M SE APARTMENT DIRECT AIR 0.463847
M NE APARTMENT DIRECT AIR 0.422397
M N1 APARTMENT DIRECT AIR 0.322737
M N2 APARTMENT DIRECT AIR 0.320618
M S1 APARTMENT DIRECT AIR 0.330645
M S2 APARTMENT DIRECT AIR 0.331859
T SW APARTMENT DIRECT AIR 0.378074
T NW APARTMENT DIRECT AIR 0.365614
T SE APARTMENT DIRECT AIR 0.338211
T NE APARTMENT DIRECT AIR 0.303390
T N1 APARTMENT DIRECT AIR 0.236535
T N2 APARTMENT DIRECT AIR 0.236652
T S1 APARTMENT DIRECT AIR 0.268999
T S2 APARTMENT DIRECT AIR 0.269671


Branch

Maximum Flow Rate [m3/s]
SPLIT GSW MAIN BRANCH 0.203491
SPLIT GNW MAIN BRANCH 0.200917
SPLIT OFFICE MAIN BRANCH 0.547152
SPLIT GNE MAIN BRANCH 0.148040
SPLIT GN1 MAIN BRANCH 0.115461
SPLIT GN2 MAIN BRANCH 0.114182
SPLIT GS1 MAIN BRANCH 0.115348
SPLIT GS2 MAIN BRANCH 0.118851
SPLIT MSW MAIN BRANCH 0.546733
SPLIT MNW MAIN BRANCH 0.537562
SPLIT MSE MAIN BRANCH 0.463847
SPLIT MNE MAIN BRANCH 0.422397
SPLIT MN1 MAIN BRANCH 0.322737
SPLIT MN2 MAIN BRANCH 0.320618
SPLIT MS1 MAIN BRANCH 0.330645
SPLIT MS2 MAIN BRANCH 0.331859
SPLIT TSW MAIN BRANCH 0.378074
SPLIT TNW MAIN BRANCH 0.365614
SPLIT TSE MAIN BRANCH 0.338211
SPLIT TNE MAIN BRANCH 0.303390
SPLIT TN1 MAIN BRANCH 0.236535
SPLIT TN2 MAIN BRANCH 0.236652
SPLIT TS1 MAIN BRANCH 0.268999
SPLIT TS2 MAIN BRANCH 0.269671


AirLoopHVAC

Design Supply Air Flow Rate [m3/s]
SPLIT GSW 0.203491
SPLIT GNW 0.200917
SPLIT OFFICE 0.547152
SPLIT GNE 0.148040
SPLIT GN1 0.115461
SPLIT GN2 0.114182
SPLIT GS1 0.115348
SPLIT GS2 0.118851
SPLIT MSW 0.546733
SPLIT MNW 0.537562
SPLIT MSE 0.463847
SPLIT MNE 0.422397
SPLIT MN1 0.322737
SPLIT MN2 0.320618
SPLIT MS1 0.330645
SPLIT MS2 0.331859
SPLIT TSW 0.378074
SPLIT TNW 0.365614
SPLIT TSE 0.338211
SPLIT TNE 0.303390
SPLIT TN1 0.236535
SPLIT TN2 0.236652
SPLIT TS1 0.268999
SPLIT TS2 0.269671


Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
SPLIT GSW OA CONTROLLER 0.203491 0.026898
SPLIT GNW OA CONTROLLER 0.200917 0.025953
SPLIT OFFICE OA CONTROLLER 0.547152 0.038104
SPLIT GNE OA CONTROLLER 0.148040 0.025953
SPLIT GN1 OA CONTROLLER 0.115461 0.025953
SPLIT GN2 OA CONTROLLER 0.114182 0.025953
SPLIT GS1 OA CONTROLLER 0.115348 0.025953
SPLIT GS2 OA CONTROLLER 0.118851 0.025953
SPLIT MSW OA CONTROLLER 0.546733 0.051906
SPLIT MNW OA CONTROLLER 0.537562 0.051906
SPLIT MSE OA CONTROLLER 0.463847 0.051906
SPLIT MNE OA CONTROLLER 0.422397 0.051906
SPLIT MN1 OA CONTROLLER 0.322737 0.051906
SPLIT MN2 OA CONTROLLER 0.320618 0.051906
SPLIT MS1 OA CONTROLLER 0.330645 0.051906
SPLIT MS2 OA CONTROLLER 0.331859 0.051906
SPLIT TSW OA CONTROLLER 0.378074 0.025953
SPLIT TNW OA CONTROLLER 0.365614 0.025953
SPLIT TSE OA CONTROLLER 0.338211 0.025953
SPLIT TNE OA CONTROLLER 0.303390 0.025953
SPLIT TN1 OA CONTROLLER 0.236535 0.025953
SPLIT TN2 OA CONTROLLER 0.236652 0.025953
SPLIT TS1 OA CONTROLLER 0.268999 0.025953
SPLIT TS2 OA CONTROLLER 0.269671 0.025953


Coil:Cooling:DX:SingleSpeed

Rated Air Flow Rate [m3/s] Rated Total Cooling Capacity (gross) [W] Rated Sensible Heat Ratio
SPLIT GSW COOLING COIL 0.203491 3368.49 0.798655
SPLIT GNW COOLING COIL 0.200917 3325.89 0.798655
SPLIT OFFICE COOLING COIL 0.547152 9057.32 0.798655
SPLIT GNE COOLING COIL 0.148040 2450.59 0.798655
SPLIT GN1 COOLING COIL 0.115461 1911.29 0.798655
SPLIT GN2 COOLING COIL 0.114182 1890.11 0.798655
SPLIT GS1 COOLING COIL 0.115348 1909.42 0.798655
SPLIT GS2 COOLING COIL 0.118851 1967.40 0.798655
SPLIT MSW COOLING COIL 0.546733 9050.38 0.798655
SPLIT MNW COOLING COIL 0.537562 8898.57 0.798655
SPLIT MSE COOLING COIL 0.463847 7678.31 0.798655
SPLIT MNE COOLING COIL 0.422397 6992.17 0.798655
SPLIT MN1 COOLING COIL 0.322737 5342.45 0.798655
SPLIT MN2 COOLING COIL 0.320618 5307.36 0.798655
SPLIT MS1 COOLING COIL 0.330645 5473.34 0.798655
SPLIT MS2 COOLING COIL 0.331859 5493.45 0.798655
SPLIT TSW COOLING COIL 0.378074 6258.47 0.798655
SPLIT TNW COOLING COIL 0.365614 6052.20 0.798655
SPLIT TSE COOLING COIL 0.338211 5598.59 0.798655
SPLIT TNE COOLING COIL 0.303390 5022.19 0.798655
SPLIT TN1 COOLING COIL 0.236535 3915.49 0.798655
SPLIT TN2 COOLING COIL 0.236652 3917.43 0.798655
SPLIT TS1 COOLING COIL 0.268999 4452.89 0.798655
SPLIT TS2 COOLING COIL 0.269671 4464.02 0.798655


AirLoopHVAC:Unitary:Furnace:HeatCool

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
SPLIT GSW FURNACE WITH DX COOLING 0.203491 0.203491 0.203491 0.203491 2219.07 3368.49 1.00
SPLIT GNW FURNACE WITH DX COOLING 0.200917 0.200917 0.200917 0.200917 2201.53 3325.89 1.00
SPLIT OFFICE FURNACE WITH DX COOLING 0.547152 0.547152 0.547152 0.547152 4091.08 9057.32 1.00
SPLIT GNE FURNACE WITH DX COOLING 0.148040 0.148040 0.148040 0.148040 2201.53 2450.59 1.00
SPLIT GN1 FURNACE WITH DX COOLING 0.115461 0.115461 0.115461 0.115461 1610.17 1911.29 1.00
SPLIT GN2 FURNACE WITH DX COOLING 0.114182 0.114182 0.114182 0.114182 1610.17 1890.11 1.00
SPLIT GS1 FURNACE WITH DX COOLING 0.115348 0.115348 0.115348 0.115348 1601.92 1909.42 1.00
SPLIT GS2 FURNACE WITH DX COOLING 0.118851 0.118851 0.118851 0.118851 1701.15 1967.40 1.00
SPLIT MSW FURNACE WITH DX COOLING 0.546733 0.546733 0.546733 0.546733 4382.89 9050.38 1.00
SPLIT MNW FURNACE WITH DX COOLING 0.537562 0.537562 0.537562 0.537562 4407.95 8898.57 1.00
SPLIT MSE FURNACE WITH DX COOLING 0.463847 0.463847 0.463847 0.463847 4382.89 7678.31 1.00
SPLIT MNE FURNACE WITH DX COOLING 0.422397 0.422397 0.422397 0.422397 4407.95 6992.17 1.00
SPLIT MN1 FURNACE WITH DX COOLING 0.322737 0.322737 0.322737 0.322737 2990.99 5342.45 1.00
SPLIT MN2 FURNACE WITH DX COOLING 0.320618 0.320618 0.320618 0.320618 2990.99 5307.36 1.00
SPLIT MS1 FURNACE WITH DX COOLING 0.330645 0.330645 0.330645 0.330645 2990.99 5473.34 1.00
SPLIT MS2 FURNACE WITH DX COOLING 0.331859 0.331859 0.331859 0.331859 2990.99 5493.45 1.00
SPLIT TSW FURNACE WITH DX COOLING 0.378074 0.378074 0.378074 0.378074 3428.01 6258.47 1.00
SPLIT TNW FURNACE WITH DX COOLING 0.365614 0.365614 0.365614 0.365614 3442.67 6052.20 1.00
SPLIT TSE FURNACE WITH DX COOLING 0.338211 0.338211 0.338211 0.338211 3428.01 5598.59 1.00
SPLIT TNE FURNACE WITH DX COOLING 0.303390 0.303390 0.303390 0.303390 3442.67 5022.19 1.00
SPLIT TN1 FURNACE WITH DX COOLING 0.236535 0.236535 0.236535 0.236535 2638.78 3915.49 1.00
SPLIT TN2 FURNACE WITH DX COOLING 0.236652 0.236652 0.236652 0.236652 2638.78 3917.43 1.00
SPLIT TS1 FURNACE WITH DX COOLING 0.268999 0.268999 0.268999 0.268999 2622.14 4452.89 1.00
SPLIT TS2 FURNACE WITH DX COOLING 0.269671 0.269671 0.269671 0.269671 2622.14 4464.02 1.00


Fan:OnOff

Maximum Flow Rate [m3/s]
SPLIT GSW SUPPLY FAN 0.203491
SPLIT GNW SUPPLY FAN 0.200917
SPLIT OFFICE SUPPLY FAN 0.547152
SPLIT GNE SUPPLY FAN 0.148040
SPLIT GN1 SUPPLY FAN 0.115461
SPLIT GN2 SUPPLY FAN 0.114182
SPLIT GS1 SUPPLY FAN 0.115348
SPLIT GS2 SUPPLY FAN 0.118851
SPLIT MSW SUPPLY FAN 0.546733
SPLIT MNW SUPPLY FAN 0.537562
SPLIT MSE SUPPLY FAN 0.463847
SPLIT MNE SUPPLY FAN 0.422397
SPLIT MN1 SUPPLY FAN 0.322737
SPLIT MN2 SUPPLY FAN 0.320618
SPLIT MS1 SUPPLY FAN 0.330645
SPLIT MS2 SUPPLY FAN 0.331859
SPLIT TSW SUPPLY FAN 0.378074
SPLIT TNW SUPPLY FAN 0.365614
SPLIT TSE SUPPLY FAN 0.338211
SPLIT TNE SUPPLY FAN 0.303390
SPLIT TN1 SUPPLY FAN 0.236535
SPLIT TN2 SUPPLY FAN 0.236652
SPLIT TS1 SUPPLY FAN 0.268999
SPLIT TS2 SUPPLY FAN 0.269671


Coil:Heating:Gas

Nominal Capacity [W]
SPLIT GSW HEATING COIL 2219.07
SPLIT GNW HEATING COIL 2201.53
SPLIT OFFICE HEATING COIL 4091.08
SPLIT GNE HEATING COIL 2201.53
SPLIT GN1 HEATING COIL 1610.17
SPLIT GN2 HEATING COIL 1610.17
SPLIT GS1 HEATING COIL 1601.92
SPLIT GS2 HEATING COIL 1701.15
SPLIT MSW HEATING COIL 4382.89
SPLIT MNW HEATING COIL 4407.95
SPLIT MSE HEATING COIL 4382.89
SPLIT MNE HEATING COIL 4407.95
SPLIT MN1 HEATING COIL 2990.99
SPLIT MN2 HEATING COIL 2990.99
SPLIT MS1 HEATING COIL 2990.99
SPLIT MS2 HEATING COIL 2990.99
SPLIT TSW HEATING COIL 3428.01
SPLIT TNW HEATING COIL 3442.67
SPLIT TSE HEATING COIL 3428.01
SPLIT TNE HEATING COIL 3442.67
SPLIT TN1 HEATING COIL 2638.78
SPLIT TN2 HEATING COIL 2638.78
SPLIT TS1 HEATING COIL 2622.14
SPLIT TS2 HEATING COIL 2622.14



Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:12

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

None


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
G SWALL SWA GWINDOW1 S SWA |
G WWALL SWA GWINDOW1 W SWA |
G NWALL NWA GWINDOW1 N NWA |
G WWALL NWA GWINDOW1 W NWA |
G SWALL SEA GWINDOW1 S SEA |
G EWALL SEA GWINDOW1 E SEA |
G NWALL NEA GWINDOW1 N NEA |
G EWALL NEA GWINDOW1 E NEA |
G NWALL N1A GWINDOW1 N N1A |
G NWALL N2A GWINDOW1 N N2A |
G SWALL S1A GWINDOW1 S S1A |
G SWALL S2A GWINDOW1 S S2A |
M WWALL SWA MWINDOW1 W SWA |
M SWALL SWA MWINDOW1 S SWA |
M NWALL NWA MWINDOW1 N NWA |
M WWALL NWA MWINDOW1 W NWA |
M EWALL SEA MWINDOW1 E SEA |
M SWALL SEA MWINDOW1 S SEA |
M NWALL NEA MWINDOW1 N NEA |
M EWALL NEA MWINDOW1 E NEA |
M NWALL N1A MWINDOW1 N N1A |
M NWALL N2A MWINDOW1 N N2A |
M SWALL S1A MWINDOW1 S S1A |
M SWALL S2A MWINDOW1 S S2A |
T WWALL SWA TWINDOW1 W SWA |
T SWALL SWA TWINDOW1 S SWA |
T NWALL NWA TWINDOW1 N NWA |
T WWALL NWA TWINDOW1 W NWA |
T EWALL SEA TWINDOW1 E SEA |
T SWALL SEA TWINDOW1 S SEA |
T NWALL NEA TWINDOW1 N NEA |
T EWALL NEA TWINDOW1 E NEA |
T NWALL N1A TWINDOW1 N N1A |
T NWALL N2A TWINDOW1 N N2A |
T SWALL S1A TWINDOW1 S S1A |
T SWALL S2A TWINDOW1 S S2A |
T EWALL C TWINDOW14 |
G EWALL C ENTRANCE DOOR |
M EWALL C MWINDOW14 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2015-09-09 18:47:12

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G SW APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.16 2.60
February 22.27 4.29
March 22.43 8.77
April 23.16 13.91
May 23.61 17.82
June 24.32 23.21
July 24.40 25.63
August 24.40 24.08
September 24.39 20.49
October 23.54 13.71
November 22.59 6.96
December 22.14 2.07
     
Annual Sum or Average 23.29 13.68
Minimum of Months 22.14 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NW APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.74 2.60
February 21.82 4.29
March 22.03 8.77
April 22.86 13.91
May 23.57 17.82
June 24.33 23.21
July 24.40 25.63
August 24.40 24.08
September 24.38 20.49
October 23.05 13.71
November 21.89 6.96
December 21.72 2.07
     
Annual Sum or Average 23.02 13.68
Minimum of Months 21.72 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: OFFICE

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.12 2.60
February 22.42 4.29
March 23.19 8.77
April 24.37 13.91
May 24.99 17.82
June 26.46 23.21
July 27.10 25.63
August 26.83 24.08
September 26.67 20.49
October 24.76 13.71
November 23.18 6.96
December 22.17 2.07
     
Annual Sum or Average 24.53 13.68
Minimum of Months 22.12 2.07
Maximum of Months 27.10 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G NE APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 2.60
February 21.76 4.29
March 21.95 8.77
April 22.85 13.91
May 23.54 17.82
June 24.32 23.21
July 24.40 25.63
August 24.40 24.08
September 24.36 20.49
October 22.96 13.71
November 21.80 6.96
December 21.70 2.07
     
Annual Sum or Average 22.98 13.68
Minimum of Months 21.70 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N1 APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 2.60
February 21.75 4.29
March 21.87 8.77
April 22.60 13.91
May 23.38 17.82
June 24.32 23.21
July 24.40 25.63
August 24.40 24.08
September 24.37 20.49
October 22.88 13.71
November 21.80 6.96
December 21.70 2.07
     
Annual Sum or Average 22.94 13.68
Minimum of Months 21.70 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G N2 APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.70 2.60
February 21.74 4.29
March 21.87 8.77
April 22.60 13.91
May 23.38 17.82
June 24.32 23.21
July 24.40 25.63
August 24.40 24.08
September 24.37 20.49
October 22.87 13.71
November 21.79 6.96
December 21.70 2.07
     
Annual Sum or Average 22.94 13.68
Minimum of Months 21.70 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S1 APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.17 2.60
February 22.25 4.29
March 22.36 8.77
April 23.00 13.91
May 23.47 17.82
June 24.32 23.21
July 24.40 25.63
August 24.40 24.08
September 24.39 20.49
October 23.55 13.71
November 22.62 6.96
December 22.16 2.07
     
Annual Sum or Average 23.26 13.68
Minimum of Months 22.16 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G S2 APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.17 2.60
February 22.26 4.29
March 22.39 8.77
April 23.05 13.91
May 23.52 17.82
June 24.33 23.21
July 24.40 25.63
August 24.40 24.08
September 24.39 20.49
October 23.58 13.71
November 22.64 6.96
December 22.17 2.07
     
Annual Sum or Average 23.28 13.68
Minimum of Months 22.17 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SW APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.06 2.60
February 23.23 4.29
March 23.79 8.77
April 24.28 13.91
May 24.34 17.82
June 24.39 23.21
July 24.40 25.63
August 24.40 24.08
September 24.40 20.49
October 24.23 13.71
November 23.90 6.96
December 23.10 2.07
     
Annual Sum or Average 23.96 13.68
Minimum of Months 23.06 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NW APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.94 2.60
February 22.23 4.29
March 23.11 8.77
April 24.19 13.91
May 24.33 17.82
June 24.39 23.21
July 24.40 25.63
August 24.40 24.08
September 24.40 20.49
October 24.01 13.71
November 22.82 6.96
December 21.86 2.07
     
Annual Sum or Average 23.51 13.68
Minimum of Months 21.86 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M SE APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.01 2.60
February 23.14 4.29
March 23.76 8.77
April 24.28 13.91
May 24.35 17.82
June 24.39 23.21
July 24.40 25.63
August 24.40 24.08
September 24.40 20.49
October 24.21 13.71
November 23.85 6.96
December 23.05 2.07
     
Annual Sum or Average 23.94 13.68
Minimum of Months 23.01 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M NE APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.87 2.60
February 22.12 4.29
March 23.05 8.77
April 24.18 13.91
May 24.34 17.82
June 24.39 23.21
July 24.40 25.63
August 24.40 24.08
September 24.40 20.49
October 23.95 13.71
November 22.63 6.96
December 21.77 2.07
     
Annual Sum or Average 23.46 13.68
Minimum of Months 21.77 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N1 APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.93 2.60
February 22.21 4.29
March 23.23 8.77
April 24.23 13.91
May 24.35 17.82
June 24.40 23.21
July 24.40 25.63
August 24.40 24.08
September 24.40 20.49
October 24.07 13.71
November 22.92 6.96
December 21.84 2.07
     
Annual Sum or Average 23.54 13.68
Minimum of Months 21.84 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M N2 APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.92 2.60
February 22.20 4.29
March 23.23 8.77
April 24.23 13.91
May 24.36 17.82
June 24.40 23.21
July 24.40 25.63
August 24.40 24.08
September 24.40 20.49
October 24.06 13.71
November 22.90 6.96
December 21.84 2.07
     
Annual Sum or Average 23.53 13.68
Minimum of Months 21.84 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S1 APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.43 2.60
February 23.57 4.29
March 24.03 8.77
April 24.33 13.91
May 24.37 17.82
June 24.40 23.21
July 24.40 25.63
August 24.40 24.08
September 24.40 20.49
October 24.30 13.71
November 24.13 6.96
December 23.53 2.07
     
Annual Sum or Average 24.11 13.68
Minimum of Months 23.43 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M S2 APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 23.42 2.60
February 23.56 4.29
March 24.03 8.77
April 24.33 13.91
May 24.37 17.82
June 24.40 23.21
July 24.40 25.63
August 24.40 24.08
September 24.40 20.49
October 24.30 13.71
November 24.13 6.96
December 23.53 2.07
     
Annual Sum or Average 24.11 13.68
Minimum of Months 23.42 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SW APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.50 2.60
February 22.68 4.29
March 22.96 8.77
April 23.77 13.91
May 24.12 17.82
June 24.34 23.21
July 24.40 25.63
August 24.40 24.08
September 24.38 20.49
October 23.78 13.71
November 23.02 6.96
December 22.54 2.07
     
Annual Sum or Average 23.58 13.68
Minimum of Months 22.50 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NW APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.94 2.60
February 22.16 4.29
March 22.62 8.77
April 23.63 13.91
May 24.10 17.82
June 24.34 23.21
July 24.40 25.63
August 24.40 24.08
September 24.37 20.49
October 23.52 13.71
November 22.34 6.96
December 21.83 2.07
     
Annual Sum or Average 23.31 13.68
Minimum of Months 21.83 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T SE APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.49 2.60
February 22.67 4.29
March 22.97 8.77
April 23.80 13.91
May 24.13 17.82
June 24.34 23.21
July 24.40 25.63
August 24.40 24.08
September 24.37 20.49
October 23.77 13.71
November 23.01 6.96
December 22.55 2.07
     
Annual Sum or Average 23.58 13.68
Minimum of Months 22.49 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T NE APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.85 2.60
February 22.10 4.29
March 22.63 8.77
April 23.66 13.91
May 24.08 17.82
June 24.33 23.21
July 24.40 25.63
August 24.40 24.08
September 24.35 20.49
October 23.50 13.71
November 22.23 6.96
December 21.75 2.07
     
Annual Sum or Average 23.28 13.68
Minimum of Months 21.75 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N1 APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.84 2.60
February 22.08 4.29
March 22.58 8.77
April 23.65 13.91
May 24.12 17.82
June 24.36 23.21
July 24.40 25.63
August 24.40 24.08
September 24.38 20.49
October 23.51 13.71
November 22.22 6.96
December 21.75 2.07
     
Annual Sum or Average 23.28 13.68
Minimum of Months 21.75 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T N2 APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 21.84 2.60
February 22.07 4.29
March 22.58 8.77
April 23.65 13.91
May 24.12 17.82
June 24.36 23.21
July 24.40 25.63
August 24.40 24.08
September 24.38 20.49
October 23.52 13.71
November 22.21 6.96
December 21.75 2.07
     
Annual Sum or Average 23.28 13.68
Minimum of Months 21.75 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S1 APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.59 2.60
February 22.79 4.29
March 23.08 8.77
April 23.85 13.91
May 24.17 17.82
June 24.36 23.21
July 24.40 25.63
August 24.40 24.08
September 24.39 20.49
October 23.87 13.71
November 23.15 6.96
December 22.65 2.07
     
Annual Sum or Average 23.65 13.68
Minimum of Months 22.59 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T S2 APARTMENT

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.59 2.60
February 22.79 4.29
March 23.08 8.77
April 23.85 13.91
May 24.17 17.82
June 24.36 23.21
July 24.40 25.63
August 24.40 24.08
September 24.39 20.49
October 23.87 13.71
November 23.15 6.96
December 22.65 2.07
     
Annual Sum or Average 23.65 13.68
Minimum of Months 22.59 2.07
Maximum of Months 24.40 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: T CORRIDOR

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 22.08 2.60
February 22.53 4.29
March 23.45 8.77
April 24.99 13.91
May 25.78 17.82
June 26.63 23.21
July 27.03 25.63
August 26.90 24.08
September 26.38 20.49
October 24.87 13.71
November 23.09 6.96
December 21.99 2.07
     
Annual Sum or Average 24.65 13.68
Minimum of Months 21.99 2.07
Maximum of Months 27.03 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: G CORRIDOR

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 19.90 2.60
February 20.31 4.29
March 21.30 8.77
April 22.69 13.91
May 23.76 17.82
June 26.10 23.21
July 26.76 25.63
August 26.49 24.08
September 25.82 20.49
October 23.10 13.71
November 21.03 6.96
December 19.82 2.07
     
Annual Sum or Average 23.10 13.68
Minimum of Months 19.82 2.07
Maximum of Months 26.76 25.63



Table of Contents

Report: MONTHLY INDOOR TEMP

For: M CORRIDOR

Timestamp: 2015-09-09 18:47:12

ZONE MEAN AIR TEMPERATURE [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 24.12 2.60
February 24.38 4.29
March 25.26 8.77
April 26.27 13.91
May 26.51 17.82
June 26.83 23.21
July 26.96 25.63
August 26.92 24.08
September 26.76 20.49
October 26.20 13.71
November 25.17 6.96
December 24.09 2.07
     
Annual Sum or Average 25.79 13.68
Minimum of Months 24.09 2.07
Maximum of Months 26.96 25.63



Table of Contents

Report: PEAK ELECTRICAL DEMAND

For: Meter

Timestamp: 2015-09-09 18:47:12

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum}[W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] FANS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY [Invalid/Undefined] HEATREJECTION:ELECTRICITY [Invalid/Undefined] EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] HEATRECOVERY:ELECTRICITY [Invalid/Undefined] WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] REFRIGERATION:ELECTRICITY [Invalid/Undefined] GENERATORS:ELECTRICITY [Invalid/Undefined] ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined]
January 0.118549E+12 72050.147 01-JAN-18:15 4979.953 26630.920 8400.977 0.000 968.957 2553.000 0.000 0.000 0.000 0.000 0.000 28516.339 0.000 0.000 0.000
February 0.107420E+12 73234.668 19-FEB-18:30 4979.953 26630.920 8400.977 0.000 1541.961 2553.000 0.000 0.000 0.000 0.000 0.000 29127.856 0.000 0.000 0.000
March 0.118639E+12 70758.034 08-MAR-18:00 4979.953 26630.920 8400.977 0.000 2160.618 2553.000 0.000 0.000 0.000 0.000 0.000 26032.565 0.000 0.000 0.000
April 0.118284E+12 74180.056 13-APR-16:45 4276.255 26730.986 8400.977 0.000 12886.341 0.000 0.000 0.000 0.000 0.000 0.000 21885.496 0.000 0.000 0.000
May 0.124690E+12 78420.022 19-MAY-17:30 4979.953 26630.920 8400.977 0.000 16017.001 0.000 0.000 0.000 0.000 0.000 0.000 22391.170 0.000 0.000 0.000
June 0.129868E+12 81623.131 28-JUN-17:15 4979.953 26630.920 8400.977 0.000 22303.896 0.000 0.000 0.000 0.000 0.000 0.000 19307.383 0.000 0.000 0.000
July 0.140147E+12 82340.841 21-JUL-17:30 4979.953 26630.920 8400.977 0.000 22755.176 0.000 0.000 0.000 0.000 0.000 0.000 19573.814 0.000 0.000 0.000
August 0.137216E+12 79569.826 20-AUG-17:30 4979.953 26630.920 8400.977 0.000 20674.710 0.000 0.000 0.000 0.000 0.000 0.000 18883.265 0.000 0.000 0.000
September 0.125847E+12 78618.743 02-SEP-17:45 4979.953 26630.920 8400.977 0.000 16330.136 0.000 0.000 0.000 0.000 0.000 0.000 22276.756 0.000 0.000 0.000
October 0.121337E+12 74560.103 04-OCT-17:45 4979.953 26630.920 8400.977 0.000 10713.280 2553.000 0.000 0.000 0.000 0.000 0.000 21281.971 0.000 0.000 0.000
November 0.112964E+12 68361.792 22-NOV-18:15 4979.953 26630.920 8400.977 0.000 2724.797 2553.000 0.000 0.000 0.000 0.000 0.000 23072.144 0.000 0.000 0.000
December 0.117047E+12 70903.165 31-DEC-18:30 4979.953 26630.920 8400.977 0.000 1540.430 2553.000 0.000 0.000 0.000 0.000 0.000 26797.884 0.000 0.000 0.000
                                     
Annual Sum or Average 0.147201E+13                 0.000 0.000 0.000 0.000 0.000   0.000 0.000 0.000
Minimum of Months 0.107420E+12 68361.792   4276.255 26630.920 8400.977 0.000 968.957 0.000 0.000 0.000 0.000 0.000 0.000 18883.265 0.000 0.000 0.000
Maximum of Months 0.140147E+12 82340.841   4979.953 26730.986 8400.977 0.000 22755.176 2553.000 0.000 0.000 0.000 0.000 0.000 29127.856 0.000 0.000 0.000



Table of Contents

Report: PEAK GAS DEMAND

For: Meter

Timestamp: 2015-09-09 18:47:12

GAS:FACILITY [J] GAS:FACILITY {Maximum}[W] GAS:FACILITY {TIMESTAMP} GAS:HVAC {AT MAX/MIN} [W] INTERIOREQUIPMENT:GAS [Invalid/Undefined] MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] GAS:PLANT [Invalid/Undefined] WATERSYSTEMS:GAS [Invalid/Undefined] WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] HEATING:GAS {AT MAX/MIN} [W]
January 0.373039E+11 60925.697 18-JAN-01:15 60925.697 0.000 0.000 0.000 0.000 0.000 60925.697
February 0.264112E+11 59335.752 06-FEB-04:00 59335.752 0.000 0.000 0.000 0.000 0.000 59335.752
March 0.104531E+11 35447.678 04-MAR-05:00 35447.678 0.000 0.000 0.000 0.000 0.000 35447.678
April 0.183089E+10 14959.375 08-APR-01:00 14959.375 0.000 0.000 0.000 0.000 0.000 14959.375
May 0.487201E+09 9546.112 05-MAY-04:00 9546.112 0.000 0.000 0.000 0.000 0.000 9546.112
June 296808.060 166.462 09-JUN-04:45 166.462 0.000 0.000 0.000 0.000 0.000 166.462
July 0.000 0.000 01-JUL-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
August 0.000 0.000 01-AUG-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
September 0.000 0.000 01-SEP-00:15 0.000 0.000 0.000 0.000 0.000 0.000 0.000
October 0.278564E+10 25889.244 26-OCT-03:00 25889.244 0.000 0.000 0.000 0.000 0.000 25889.244
November 0.119365E+11 40187.500 26-NOV-05:00 40187.500 0.000 0.000 0.000 0.000 0.000 40187.500
December 0.359691E+11 60798.425 14-DEC-03:00 60798.425 0.000 0.000 0.000 0.000 0.000 60798.425
                     
Annual Sum or Average 0.127178E+12       0.000 0.000 0.000 0.000 0.000  
Minimum of Months 0.000 0.000   0.000 0.000 0.000 0.000 0.000 0.000 0.000
Maximum of Months 0.373039E+11 60925.697   60925.697 0.000 0.000 0.000 0.000 0.000 60925.697