Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:47
Tabular Output Report in Format: HTML
Building: Mid-Rise Apartment
Environment: Chicago Ohare Intl Ap IL USA TMY3 WMO#=725300
Simulation Timestamp: 2015-09-09 18:47:16
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:16
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 2009.85 | 641.18 | 711.71 |
Net Site Energy | 2009.85 | 641.18 | 711.71 |
Total Source Energy | 5167.51 | 1648.53 | 1829.87 |
Net Source Energy | 5167.51 | 1648.53 | 1829.87 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 3134.61 |
Net Conditioned Building Area | 2823.98 |
Unconditioned Building Area | 310.64 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 574.98 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 116.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 118.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 40.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 517.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 230.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 411.79 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1434.87 | 574.98 | 0.00 | 0.00 | 0.00 | 1874.72 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 574.98 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 116.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 96.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 22.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 40.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 517.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 230.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 411.79 | 0.00 | 0.00 | 0.00 | 0.00 | 1874.72 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 56.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 268.66 | 203.61 | 0.00 | 0.00 | 0.00 | 0.66 |
Other | 183.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 508.10 | 203.61 | 0.00 | 0.00 | 0.00 | 0.66 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 50.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 242.03 | 183.43 | 0.00 | 0.00 | 0.00 | 0.60 |
Other | 165.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 457.75 | 183.43 | 0.00 | 0.00 | 0.00 | 0.60 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 1434.87 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 1434.87 | 100.00 |
Total On-Site and Utility Electric Sources | 1434.87 | 100.00 |
Total Electricity End Uses | 1434.87 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 1874.72 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 1874.72 | 100.00 |
Total Water End Uses | 1874.72 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 43.00 |
Time Setpoint Not Met During Occupied Cooling | 0.75 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 3403.00 |
Table of Contents
TopMONTHLY INDOOR TEMP
| G SW APARTMENT | G NW APARTMENT | OFFICE | G NE APARTMENT | G N1 APARTMENT | G N2 APARTMENT | G S1 APARTMENT | G S2 APARTMENT | M SW APARTMENT | M NW APARTMENT | M SE APARTMENT | M NE APARTMENT | M N1 APARTMENT | M N2 APARTMENT | M S1 APARTMENT | M S2 APARTMENT | T SW APARTMENT | T NW APARTMENT | T SE APARTMENT | T NE APARTMENT | T N1 APARTMENT | T N2 APARTMENT | T S1 APARTMENT | T S2 APARTMENT | T CORRIDOR | G CORRIDOR | M CORRIDOR |PEAK ELECTRICAL DEMAND
| Meter |PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:16
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.09 18:47 |
RunPeriod | Chicago Ohare Intl Ap IL USA TMY3 WMO#=725300 |
Weather File | Chicago Ohare Intl Ap IL USA TMY3 WMO#=725300 |
Latitude [deg] | 41.98 |
Longitude [deg] | -87.9 |
Elevation [m] | 201.00 |
Time Zone | -6.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1542.04 | 564.80 | 206.22 | 564.80 | 206.22 |
Window Opening Area [m2] | 306.92 | 112.97 | 37.16 | 112.97 | 43.82 |
Window-Wall Ratio [%] | 19.90 | 20.00 | 18.02 | 20.00 | 21.25 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1501.17 | 564.80 | 185.79 | 564.80 | 185.79 |
Window Opening Area [m2] | 300.26 | 112.97 | 37.16 | 112.97 | 37.16 |
Window-Wall Ratio [%] | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Total | |
Gross Roof Area [m2] | 783.65 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
G SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
G NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
OFFICE | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 26.1977 | 88.25 | 6.6700 |
G NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
G N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
G N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
G S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
G S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
M SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
M NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
M SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
M NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
M N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
M N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
M S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
M S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 2.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
T SW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
T NW APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
T SE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
T NE APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 58.52 | 11.71 | 3.6746 | 35.30 | 6.6700 |
T N1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
T N2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
T S1 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
T S2 APARTMENT | 88.25 | Yes | Yes | 268.97 | 1.00 | 35.30 | 7.06 | 3.6746 | 35.30 | 6.6700 |
T CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 1.11 | 5.9540 | 0.0000 | |
G CORRIDOR | 77.66 | No | Yes | 236.69 | 1.00 | 10.22 | 3.32 | 5.9540 | 208.8202 | |
M CORRIDOR | 77.66 | No | Yes | 236.69 | 2.00 | 10.22 | 1.11 | 5.9540 | 0.0000 | |
Total | 3134.61 | 9553.84 | 1542.04 | 306.92 | 4.5346 | 39.93 | 11.1825 | |||
Conditioned Total | 2823.98 | 8607.06 | 1501.17 | 300.26 | 4.3785 | 35.97 | 6.6700 | |||
Unconditioned Total | 310.64 | 946.78 | 40.87 | 6.66 | 5.9540 | 52.2051 | ||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:16
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 16-JUL-17:00 | 27-JAN-00:00 | - | - | - | 01-JAN-07:15 |
Heating | 0.00 | 159144.11 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 25197.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 4979.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 26630.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 7311.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 24933.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 89053.59 | 159144.11 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 159144.11 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 25197.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GeneralLights | 4056.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GeneralLights-plugin | 923.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 26630.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 7311.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 24933.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:16
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 623.28 | 0.00 | 0.00 | 0.00 |
Cooling | 368.38 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 375.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 126.91 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1639.40 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 730.21 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 1304.15 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 4544.23 | 623.28 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 220.71 | 0.00 | 0.00 | 0.00 |
Cooling | 130.45 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 132.85 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.94 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 580.53 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 258.58 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 461.81 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1609.16 | 220.71 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 220.71 | 0.00 | 0.00 | 0.00 |
Cooling | 130.45 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 132.85 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 44.94 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 580.53 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 258.58 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 461.81 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1609.16 | 220.71 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:16
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | -20.00 | 0.00 | -20.00 | Wetbulb [C] | 4.90 | 270.00 |
CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 33.30 | 10.50 | 23.70 | Wetbulb [C] | 5.20 | 230.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:16
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
G SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR SWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
G GFLOOR NWA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR SEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
G GFLOOR NEA | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
G GFLOOR N2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S1A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
G SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
G GFLOOR S2A | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 88.25 | 90.00 | 180.00 | |
M WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 270.00 | 90.00 | W |
M SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
M NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 270.00 | 90.00 | W |
M EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 90.00 | 90.00 | E |
M SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
M NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 46.45 | 90.00 | 90.00 | E |
M NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 0.00 | 90.00 | N |
M SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
M SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 70.60 | 180.00 | 90.00 | S |
T WWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T SWALL SWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T WWALL NWA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 270.00 | 90.00 | W |
T ROOF NWA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T EWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T SWALL SEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF SEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T EWALL NEA | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 23.22 | 90.00 | 90.00 | E |
T ROOF NEA | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T NWALL N2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 0.00 | 90.00 | N |
T ROOF N2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S1A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S1A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T SWALL S2A | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.30 | 180.00 | 90.00 | S |
T ROOF S2A | RES_ROOF | 0.30 | 0.269 | 0.283 | 88.25 | 180.00 | 0.00 | |
T WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
T EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
T ROOF C | RES_ROOF | 0.30 | 0.269 | 0.283 | 77.66 | 180.00 | 0.00 | |
G WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 270.00 | 90.00 | W |
G EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
G FLOOR C | INT_SLAB_CEILING | 0.30 | 1.986 | 3.839 | 77.66 | 90.00 | 180.00 | |
M WWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.22 | 270.00 | 90.00 | W |
M EWALL C | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.22 | 90.00 | 90.00 | E |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
GWINDOW1 S SWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G SWALL SWA | 180.00 | 90.00 | S | ||
GWINDOW1 W SWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | G WWALL SWA | 270.00 | 90.00 | W | ||
GWINDOW1 N NWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G NWALL NWA | 0.00 | 90.00 | N | ||
GWINDOW1 W NWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | G WWALL NWA | 270.00 | 90.00 | W | ||
GWINDOW1 S SEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G SWALL SEA | 180.00 | 90.00 | S | ||
GWINDOW1 E SEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | G EWALL SEA | 90.00 | 90.00 | E | ||
GWINDOW1 N NEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G NWALL NEA | 0.00 | 90.00 | N | ||
GWINDOW1 E NEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | G EWALL NEA | 90.00 | 90.00 | E | ||
GWINDOW1 N N1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G NWALL N1A | 0.00 | 90.00 | N | ||
GWINDOW1 N N2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G NWALL N2A | 0.00 | 90.00 | N | ||
GWINDOW1 S S1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G SWALL S1A | 180.00 | 90.00 | S | ||
GWINDOW1 S S2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | G SWALL S2A | 180.00 | 90.00 | S | ||
MWINDOW1 W SWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.653 | 0.426 | 0.308 | No | M WWALL SWA | 270.00 | 90.00 | W | ||
MWINDOW1 S SWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M SWALL SWA | 180.00 | 90.00 | S | ||
MWINDOW1 N NWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M NWALL NWA | 0.00 | 90.00 | N | ||
MWINDOW1 W NWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.653 | 0.426 | 0.308 | No | M WWALL NWA | 270.00 | 90.00 | W | ||
MWINDOW1 E SEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.653 | 0.426 | 0.308 | No | M EWALL SEA | 90.00 | 90.00 | E | ||
MWINDOW1 S SEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M SWALL SEA | 180.00 | 90.00 | S | ||
MWINDOW1 N NEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M NWALL NEA | 0.00 | 90.00 | N | ||
MWINDOW1 E NEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 9.29 | 2.653 | 0.426 | 0.308 | No | M EWALL NEA | 90.00 | 90.00 | E | ||
MWINDOW1 N N1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M NWALL N1A | 0.00 | 90.00 | N | ||
MWINDOW1 N N2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M NWALL N2A | 0.00 | 90.00 | N | ||
MWINDOW1 S S1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M SWALL S1A | 180.00 | 90.00 | S | ||
MWINDOW1 S S2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 14.12 | 2.653 | 0.426 | 0.308 | No | M SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW1 W SWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | T WWALL SWA | 270.00 | 90.00 | W | ||
TWINDOW1 S SWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T SWALL SWA | 180.00 | 90.00 | S | ||
TWINDOW1 N NWA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T NWALL NWA | 0.00 | 90.00 | N | ||
TWINDOW1 W NWA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | T WWALL NWA | 270.00 | 90.00 | W | ||
TWINDOW1 E SEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | T EWALL SEA | 90.00 | 90.00 | E | ||
TWINDOW1 S SEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T SWALL SEA | 180.00 | 90.00 | S | ||
TWINDOW1 N NEA | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T NWALL NEA | 0.00 | 90.00 | N | ||
TWINDOW1 E NEA | WINDOW_U_0.52_SHGC_0.40 | 4.65 | 0.00 | 0.00 | 4.65 | 4.65 | 2.653 | 0.426 | 0.308 | No | T EWALL NEA | 90.00 | 90.00 | E | ||
TWINDOW1 N N1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T NWALL N1A | 0.00 | 90.00 | N | ||
TWINDOW1 N N2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T NWALL N2A | 0.00 | 90.00 | N | ||
TWINDOW1 S S1A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T SWALL S1A | 180.00 | 90.00 | S | ||
TWINDOW1 S S2A | WINDOW_U_0.52_SHGC_0.40 | 7.06 | 0.00 | 0.00 | 7.06 | 7.06 | 2.653 | 0.426 | 0.308 | No | T SWALL S2A | 180.00 | 90.00 | S | ||
TWINDOW14 | WINDOW_U_0.52_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 1.11 | 2.653 | 0.426 | 0.308 | No | T EWALL C | 270.00 | 90.00 | W | ||
ENTRANCE DOOR | WINDOW_U_0.52_SHGC_0.40 | 3.32 | 0.00 | 0.00 | 3.32 | 3.32 | 2.653 | 0.426 | 0.308 | No | G EWALL C | 270.00 | 90.00 | W | ||
MWINDOW14 | WINDOW_U_0.52_SHGC_0.40 | 1.11 | 0.00 | 0.00 | 1.11 | 2.23 | 2.653 | 0.426 | 0.308 | No | M EWALL C | 270.00 | 90.00 | W | ||
Total or Average | 306.92 | 2.653 | 0.426 | 0.308 | ||||||||||||
North Total or Average | 112.97 | 2.653 | 0.426 | 0.308 | ||||||||||||
Non-North Total or Average | 193.95 | 2.653 | 0.426 | 0.308 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:16
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
GWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
GWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
GWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
GWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
GWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
GWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
GWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
MWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
MWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
MWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
MWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
MWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 W SWA | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
TWINDOW1 S SWA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NWA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 W NWA | 0.00 | 0.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 |
TWINDOW1 E SEA | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
TWINDOW1 S SEA | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 N NEA | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 E NEA | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
TWINDOW1 N N1A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 N N2A | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TWINDOW1 S S1A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW1 S S2A | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
TWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
ENTRANCE DOOR | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
MWINDOW14 | 1.00 | 1.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:16
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
LIGHTING_HARDWIRED_GSW | G SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GNW | G NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_OFFICE | OFFICE | 13.0989 | 88.25 | 1155.96 | GeneralLights | LTG_OFF_SCH | 62.17 | 168.00 | 60.95 | 0.0000 | Y | 13.23 |
LIGHTING_HARDWIRED_GNE | G NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GN1 | G N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GN2 | G N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GS1 | G S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GS2 | G S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MSW | M SW APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MNW | M NW APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MSE | M SE APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MNE | M NE APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MN1 | M N1 APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MN2 | M N2 APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MS1 | M S1 APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_MS2 | M S2 APARTMENT | 2.7059 | 176.50 | 477.59 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TSW | T SW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TNW | T NW APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TSE | T SE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TNE | T NE APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TN1 | T N1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TN2 | T N2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TS1 | T S1 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_TS2 | T S2 APARTMENT | 2.7059 | 88.25 | 238.79 | GeneralLights | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.80 |
LIGHTING_HARDWIRED_GC | G CORRIDOR | 5.9540 | 77.66 | 462.39 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 14.58 |
LIGHTING_HARDWIRED_MC | M CORRIDOR | 5.9540 | 155.32 | 924.77 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 14.58 |
LIGHTING_HARDWIRED_TC | T CORRIDOR | 5.9540 | 77.66 | 462.39 | GeneralLights | LTG_COR_SCH | 168.00 | 168.00 | 168.00 | 0.0000 | N | 14.58 |
LIGHTING_PLUGIN_GSW | G SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_GNW | G NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_OFFICE | OFFICE | 13.0989 | 88.25 | 1155.96 | GeneralLights-plugin | LTG_OFF_SCH | 62.17 | 168.00 | 60.95 | 0.0000 | Y | 13.23 |
LIGHTING_PLUGIN_GNE | G NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_GN1 | G N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_GN2 | G N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_GS1 | G S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_GS2 | G S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MSW | M SW APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MNW | M NW APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MSE | M SE APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MNE | M NE APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MN1 | M N1 APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MN2 | M N2 APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MS1 | M S1 APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_MS2 | M S2 APARTMENT | 0.9688 | 176.50 | 170.98 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TSW | T SW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TNW | T NW APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TSE | T SE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TNE | T NE APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TN1 | T N1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TN2 | T N2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TS1 | T S1 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
LIGHTING_PLUGIN_TS2 | T S2 APARTMENT | 0.9688 | 88.25 | 85.49 | GeneralLights-plugin | LTG_APT_SCH | 17.85 | 168.00 | 17.85 | 0.0000 | Y | 0.29 |
Interior Lighting Total | 2.3855 | 5958.59 | 14214.30 | 95.19 |
Zone | Daylighting Type | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
FACADE LIGHTING | 2553.00 | AstronomicalClock | - | 83.62 | 83.62 | 40.07 | |
Exterior Lighting Total | 2553.00 | 40.07 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:16
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3615.57 | 2605.16 | 1010.41 | 0.72 | 3.91 | |||
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3439.93 | 2482.07 | 957.86 | 0.72 | 3.91 | |||
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8081.51 | 6362.05 | 1719.46 | 0.79 | 3.91 | |||
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2704.56 | 1906.43 | 798.13 | 0.70 | 3.91 | |||
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2189.20 | 1512.35 | 676.86 | 0.69 | 3.91 | |||
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2171.21 | 1498.04 | 673.17 | 0.69 | 3.91 | |||
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2557.94 | 1769.06 | 788.89 | 0.69 | 3.91 | |||
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2608.08 | 1809.47 | 798.61 | 0.69 | 3.91 | |||
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9517.41 | 7002.31 | 2515.10 | 0.74 | 3.91 | |||
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9040.27 | 6642.70 | 2397.57 | 0.73 | 3.91 | |||
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8947.10 | 6484.34 | 2462.76 | 0.72 | 3.91 | |||
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7430.85 | 5383.14 | 2047.71 | 0.72 | 3.91 | |||
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5855.25 | 4175.88 | 1679.37 | 0.71 | 3.91 | |||
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5825.73 | 4152.12 | 1673.61 | 0.71 | 3.91 | |||
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6846.57 | 4884.48 | 1962.09 | 0.71 | 3.91 | |||
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6866.13 | 4900.33 | 1965.80 | 0.71 | 3.91 | |||
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6385.88 | 4743.80 | 1642.07 | 0.74 | 3.91 | |||
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5898.42 | 4374.36 | 1524.05 | 0.74 | 3.91 | |||
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6019.55 | 4445.49 | 1574.06 | 0.74 | 3.91 | |||
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5164.63 | 3749.10 | 1415.53 | 0.73 | 3.91 | |||
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4082.32 | 2943.78 | 1138.55 | 0.72 | 3.91 | |||
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4083.77 | 2944.84 | 1138.93 | 0.72 | 3.91 | |||
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4896.49 | 3604.09 | 1292.40 | 0.74 | 3.91 | |||
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4908.88 | 3614.20 | 1294.68 | 0.74 | 3.91 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
SPLIT GSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3480.3 | 3.27 | 11.15 | 11.60 | 11.07 |
SPLIT GNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3310.8 | 3.26 | 11.14 | 11.60 | 11.06 |
SPLIT OFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7710.6 | 3.15 | 10.74 | 11.16 | 10.47 |
SPLIT GNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2608.7 | 3.30 | 11.24 | 11.71 | 11.22 |
SPLIT GN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2115.6 | 3.32 | 11.33 | 11.81 | 11.36 |
SPLIT GN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2098.4 | 3.32 | 11.34 | 11.82 | 11.37 |
SPLIT GS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2471.6 | 3.32 | 11.33 | 11.81 | 11.35 |
SPLIT GS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2519.4 | 3.32 | 11.32 | 11.79 | 11.33 |
SPLIT MSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9142.9 | 3.24 | 11.05 | 11.50 | 10.93 |
SPLIT MNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8685.6 | 3.24 | 11.06 | 11.51 | 10.94 |
SPLIT MSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 8607.6 | 3.26 | 11.12 | 11.58 | 11.03 |
SPLIT MNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7149.1 | 3.26 | 11.12 | 11.58 | 11.04 |
SPLIT MN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5641.6 | 3.28 | 11.19 | 11.65 | 11.14 |
SPLIT MN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5613.5 | 3.28 | 11.19 | 11.66 | 11.15 |
SPLIT MS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6596.6 | 3.28 | 11.19 | 11.65 | 11.14 |
SPLIT MS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6615.2 | 3.28 | 11.19 | 11.65 | 11.14 |
SPLIT TSW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 6128.8 | 3.23 | 11.01 | 11.45 | 10.87 |
SPLIT TNW COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5661.9 | 3.23 | 11.01 | 11.46 | 10.88 |
SPLIT TSE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 5780.6 | 3.23 | 11.03 | 11.48 | 10.91 |
SPLIT TNE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4967.9 | 3.26 | 11.11 | 11.57 | 11.02 |
SPLIT TN1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3929.3 | 3.27 | 11.14 | 11.60 | 11.07 |
SPLIT TN2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 3930.7 | 3.27 | 11.14 | 11.60 | 11.07 |
SPLIT TS1 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4703.6 | 3.24 | 11.05 | 11.50 | 10.93 |
SPLIT TS2 COOLING COIL | Coil:Cooling:DX:SingleSpeed | 4715.4 | 3.24 | 11.05 | 11.50 | 10.93 |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
SPLIT GSW HEATING COIL | Coil:Heating:Gas | 4216.86 | 0.80 | |
SPLIT GNW HEATING COIL | Coil:Heating:Gas | 4173.98 | 0.80 | |
SPLIT OFFICE HEATING COIL | Coil:Heating:Gas | 6928.90 | 0.80 | |
SPLIT GNE HEATING COIL | Coil:Heating:Gas | 4162.43 | 0.80 | |
SPLIT GN1 HEATING COIL | Coil:Heating:Gas | 3123.07 | 0.80 | |
SPLIT GN2 HEATING COIL | Coil:Heating:Gas | 3122.81 | 0.80 | |
SPLIT GS1 HEATING COIL | Coil:Heating:Gas | 3122.83 | 0.80 | |
SPLIT GS2 HEATING COIL | Coil:Heating:Gas | 3256.81 | 0.80 | |
SPLIT MSW HEATING COIL | Coil:Heating:Gas | 8602.32 | 0.80 | |
SPLIT MNW HEATING COIL | Coil:Heating:Gas | 8606.02 | 0.80 | |
SPLIT MSE HEATING COIL | Coil:Heating:Gas | 8572.26 | 0.80 | |
SPLIT MNE HEATING COIL | Coil:Heating:Gas | 8575.94 | 0.80 | |
SPLIT MN1 HEATING COIL | Coil:Heating:Gas | 5907.26 | 0.80 | |
SPLIT MN2 HEATING COIL | Coil:Heating:Gas | 5906.53 | 0.80 | |
SPLIT MS1 HEATING COIL | Coil:Heating:Gas | 5905.97 | 0.80 | |
SPLIT MS2 HEATING COIL | Coil:Heating:Gas | 5905.25 | 0.80 | |
SPLIT TSW HEATING COIL | Coil:Heating:Gas | 6192.06 | 0.80 | |
SPLIT TNW HEATING COIL | Coil:Heating:Gas | 6195.79 | 0.80 | |
SPLIT TSE HEATING COIL | Coil:Heating:Gas | 6176.35 | 0.80 | |
SPLIT TNE HEATING COIL | Coil:Heating:Gas | 6180.07 | 0.80 | |
SPLIT TN1 HEATING COIL | Coil:Heating:Gas | 4672.09 | 0.80 | |
SPLIT TN2 HEATING COIL | Coil:Heating:Gas | 4671.68 | 0.80 | |
SPLIT TS1 HEATING COIL | Coil:Heating:Gas | 4666.85 | 0.80 | |
SPLIT TS2 HEATING COIL | Coil:Heating:Gas | 4666.45 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
SPLIT GSW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.17 | 199.67 | 1160.84 | 1.00 | General |
SPLIT GNW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.16 | 190.64 | 1160.84 | 1.00 | General |
SPLIT OFFICE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.47 | 549.12 | 1160.84 | 1.00 | General |
SPLIT GNE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.12 | 141.29 | 1160.84 | 1.00 | General |
SPLIT GN1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.09 | 108.49 | 1160.84 | 1.00 | General |
SPLIT GN2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.09 | 107.24 | 1160.84 | 1.00 | General |
SPLIT GS1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.11 | 127.14 | 1160.84 | 1.00 | General |
SPLIT GS2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.11 | 130.73 | 1160.84 | 1.00 | General |
SPLIT MSW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.48 | 553.20 | 1160.84 | 1.00 | General |
SPLIT MNW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.45 | 523.83 | 1160.84 | 1.00 | General |
SPLIT MSE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.43 | 501.29 | 1160.84 | 1.00 | General |
SPLIT MNE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.36 | 415.90 | 1160.84 | 1.00 | General |
SPLIT MN1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 315.15 | 1160.84 | 1.00 | General |
SPLIT MN2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.27 | 313.05 | 1160.84 | 1.00 | General |
SPLIT MS1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 368.81 | 1160.84 | 1.00 | General |
SPLIT MS2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.32 | 370.23 | 1160.84 | 1.00 | General |
SPLIT TSW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.33 | 379.86 | 1160.84 | 1.00 | General |
SPLIT TNW SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 349.46 | 1160.84 | 1.00 | General |
SPLIT TSE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.30 | 353.07 | 1160.84 | 1.00 | General |
SPLIT TNE SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 290.52 | 1160.84 | 1.00 | General |
SPLIT TN1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 225.89 | 1160.84 | 1.00 | General |
SPLIT TN2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.19 | 225.98 | 1160.84 | 1.00 | General |
SPLIT TS1 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 284.91 | 1160.84 | 1.00 | General |
SPLIT TS2 SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.25 | 285.82 | 1160.84 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
G SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
G S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
M S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T SW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T NW APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T SE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T NE APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T N1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T N2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T S1 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
T S2 APARTMENT WATER HEATER | WaterHeater:Mixed | 0.19 | 14653.55 | 1.00 | 3.78 | 0.90 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:16
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 1787.23 | 2144.67 | 0.143 | 0.172 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 31.57 | 0.01496 |
G NW APARTMENT | 1706.40 | 2047.68 | 0.137 | 0.164 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 30.78 | 0.01496 |
OFFICE | 4678.59 | 5614.31 | 0.394 | 0.473 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 09:30:00 | 28.42 | 0.01496 |
G NE APARTMENT | 1264.59 | 1517.51 | 0.101 | 0.122 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 29.70 | 0.01496 |
G N1 APARTMENT | 971.15 | 1165.38 | 0.078 | 0.093 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 29.99 | 0.01496 |
G N2 APARTMENT | 959.97 | 1151.96 | 0.077 | 0.092 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 29.99 | 0.01496 |
G S1 APARTMENT | 1138.04 | 1365.65 | 0.091 | 0.110 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
G S2 APARTMENT | 1170.15 | 1404.18 | 0.094 | 0.113 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
M SW APARTMENT | 4951.37 | 5941.64 | 0.397 | 0.477 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 31.57 | 0.01496 |
M NW APARTMENT | 4688.75 | 5626.50 | 0.376 | 0.451 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 30.78 | 0.01496 |
M SE APARTMENT | 4486.55 | 5383.85 | 0.360 | 0.432 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:15:00 | 32.91 | 0.01496 |
M NE APARTMENT | 3722.22 | 4466.67 | 0.299 | 0.358 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 10:15:00 | 29.70 | 0.01496 |
M N1 APARTMENT | 2820.99 | 3385.18 | 0.226 | 0.271 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 29.99 | 0.01496 |
M N2 APARTMENT | 2802.14 | 3362.57 | 0.225 | 0.270 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 18:30:00 | 29.99 | 0.01496 |
M S1 APARTMENT | 3301.13 | 3961.36 | 0.265 | 0.318 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
M S2 APARTMENT | 3313.80 | 3976.56 | 0.266 | 0.319 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
T SW APARTMENT | 3399.44 | 4079.32 | 0.273 | 0.327 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 | 32.98 | 0.01496 |
T NW APARTMENT | 3127.44 | 3752.93 | 0.251 | 0.301 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 32.04 | 0.01496 |
T SE APARTMENT | 3159.73 | 3791.67 | 0.253 | 0.304 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.04 | 0.01496 |
T NE APARTMENT | 2599.98 | 3119.97 | 0.209 | 0.250 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 33.30 | 0.01496 |
T N1 APARTMENT | 2021.78 | 2426.13 | 0.162 | 0.195 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 33.30 | 0.01496 |
T N2 APARTMENT | 2022.53 | 2427.04 | 0.162 | 0.195 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 33.30 | 0.01496 |
T S1 APARTMENT | 2549.99 | 3059.99 | 0.205 | 0.245 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 33.17 | 0.01496 |
T S2 APARTMENT | 2558.13 | 3069.76 | 0.205 | 0.246 | CHICAGO OHARE INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:45:00 | 33.17 | 0.01496 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
G SW APARTMENT | 2445.24 | 2934.29 | 0.072 | 0.086 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -20.00 | 0.00065 |
G NW APARTMENT | 2448.38 | 2938.06 | 0.072 | 0.087 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -20.00 | 0.00065 |
OFFICE | 4319.73 | 5183.67 | 0.123 | 0.148 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -20.00 | 0.00065 |
G NE APARTMENT | 2438.61 | 2926.33 | 0.072 | 0.086 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -20.00 | 0.00065 |
G N1 APARTMENT | 1559.66 | 1871.59 | 0.046 | 0.055 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -20.00 | 0.00065 |
G N2 APARTMENT | 1559.44 | 1871.32 | 0.046 | 0.055 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -20.00 | 0.00065 |
G S1 APARTMENT | 1559.45 | 1871.34 | 0.046 | 0.055 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -20.00 | 0.00065 |
G S2 APARTMENT | 1672.76 | 2007.31 | 0.049 | 0.059 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -20.00 | 0.00065 |
M SW APARTMENT | 5112.09 | 6134.50 | 0.151 | 0.181 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -20.00 | 0.00065 |
M NW APARTMENT | 5115.21 | 6138.26 | 0.151 | 0.181 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -20.00 | 0.00065 |
M SE APARTMENT | 5086.67 | 6104.00 | 0.150 | 0.180 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -20.00 | 0.00065 |
M NE APARTMENT | 5089.78 | 6107.73 | 0.150 | 0.180 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -20.00 | 0.00065 |
M N1 APARTMENT | 2832.89 | 3399.46 | 0.083 | 0.100 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -20.00 | 0.00065 |
M N2 APARTMENT | 2832.27 | 3398.72 | 0.083 | 0.100 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -20.00 | 0.00065 |
M S1 APARTMENT | 2831.79 | 3398.15 | 0.083 | 0.100 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -20.00 | 0.00065 |
M S2 APARTMENT | 2831.18 | 3397.42 | 0.083 | 0.100 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -20.00 | 0.00065 |
T SW APARTMENT | 4155.14 | 4986.17 | 0.122 | 0.147 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -20.00 | 0.00065 |
T NW APARTMENT | 4158.30 | 4989.96 | 0.123 | 0.147 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -20.00 | 0.00065 |
T SE APARTMENT | 4141.86 | 4970.23 | 0.122 | 0.146 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -20.00 | 0.00065 |
T NE APARTMENT | 4145.00 | 4974.00 | 0.122 | 0.147 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -20.00 | 0.00065 |
T N1 APARTMENT | 2869.70 | 3443.64 | 0.085 | 0.101 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -20.00 | 0.00065 |
T N2 APARTMENT | 2869.36 | 3443.23 | 0.085 | 0.101 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -20.00 | 0.00065 |
T S1 APARTMENT | 2865.27 | 3438.32 | 0.084 | 0.101 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -20.00 | 0.00065 |
T S2 APARTMENT | 2864.93 | 3437.91 | 0.084 | 0.101 | CHICAGO OHARE INTL AP ANN HTG 99.6% CONDNS DB | 1/21 04:00:00 | -20.00 | 0.00065 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
SPLIT GSW | 0.17 | 0.17 | 0.09 | 0.09 |
SPLIT GNW | 0.16 | 0.16 | 0.09 | 0.09 |
SPLIT OFFICE | 0.47 | 0.47 | 0.15 | 0.15 |
SPLIT GNE | 0.12 | 0.12 | 0.09 | 0.09 |
SPLIT GN1 | 0.09 | 0.09 | 0.06 | 0.06 |
SPLIT GN2 | 0.09 | 0.09 | 0.06 | 0.06 |
SPLIT GS1 | 0.11 | 0.11 | 0.06 | 0.06 |
SPLIT GS2 | 0.11 | 0.11 | 0.06 | 0.06 |
SPLIT MSW | 0.48 | 0.48 | 0.18 | 0.18 |
SPLIT MNW | 0.45 | 0.45 | 0.18 | 0.18 |
SPLIT MSE | 0.43 | 0.43 | 0.18 | 0.18 |
SPLIT MNE | 0.36 | 0.36 | 0.18 | 0.18 |
SPLIT MN1 | 0.27 | 0.27 | 0.10 | 0.10 |
SPLIT MN2 | 0.27 | 0.27 | 0.10 | 0.10 |
SPLIT MS1 | 0.32 | 0.32 | 0.10 | 0.10 |
SPLIT MS2 | 0.32 | 0.32 | 0.10 | 0.10 |
SPLIT TSW | 0.33 | 0.33 | 0.15 | 0.15 |
SPLIT TNW | 0.30 | 0.30 | 0.15 | 0.15 |
SPLIT TSE | 0.30 | 0.30 | 0.15 | 0.15 |
SPLIT TNE | 0.25 | 0.25 | 0.15 | 0.15 |
SPLIT TN1 | 0.19 | 0.19 | 0.10 | 0.10 |
SPLIT TN2 | 0.19 | 0.19 | 0.10 | 0.10 |
SPLIT TS1 | 0.25 | 0.25 | 0.10 | 0.10 |
SPLIT TS2 | 0.25 | 0.25 | 0.10 | 0.10 |
Report: System Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:16
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
G SW APARTMENT | 4053.25 | 6398.00 | 2208.75 |
G NW APARTMENT | 4392.75 | 6644.25 | 2793.50 |
OFFICE | 861.25 | 1426.00 | 268.00 |
G NE APARTMENT | 4397.00 | 6655.75 | 2782.00 |
G N1 APARTMENT | 3691.25 | 6797.75 | 2287.75 |
G N2 APARTMENT | 3692.50 | 6798.25 | 2288.50 |
G S1 APARTMENT | 3283.75 | 6481.75 | 1583.00 |
G S2 APARTMENT | 3484.75 | 6372.75 | 1679.25 |
M SW APARTMENT | 3726.50 | 4727.00 | 705.25 |
M NW APARTMENT | 3996.50 | 5157.75 | 1270.25 |
M SE APARTMENT | 3707.50 | 4746.25 | 688.25 |
M NE APARTMENT | 3998.50 | 5234.00 | 1278.25 |
M N1 APARTMENT | 3420.50 | 5028.00 | 719.75 |
M N2 APARTMENT | 3417.00 | 5042.25 | 720.50 |
M S1 APARTMENT | 3356.50 | 4519.75 | 275.25 |
M S2 APARTMENT | 3358.00 | 4519.75 | 277.50 |
T SW APARTMENT | 5079.25 | 5497.75 | 2464.00 |
T NW APARTMENT | 5351.50 | 5817.00 | 2950.00 |
T SE APARTMENT | 5067.25 | 5488.75 | 2425.25 |
T NE APARTMENT | 5348.75 | 5822.00 | 2927.00 |
T N1 APARTMENT | 4900.50 | 5771.75 | 2515.25 |
T N2 APARTMENT | 4904.75 | 5773.75 | 2517.50 |
T S1 APARTMENT | 4558.25 | 5379.75 | 1921.25 |
T S2 APARTMENT | 4561.00 | 5378.25 | 1923.25 |
T CORRIDOR | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 |
Facility | 6158.50 | 6868.50 | 3403.00 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
G SW APARTMENT | 3.00 | 0.00 | 3.00 | 0.00 |
G NW APARTMENT | 3.00 | 0.00 | 3.00 | 0.00 |
OFFICE | 13.00 | 11.75 | 0.00 | 0.00 |
G NE APARTMENT | 3.00 | 0.00 | 3.00 | 0.00 |
G N1 APARTMENT | 5.25 | 0.50 | 5.25 | 0.50 |
G N2 APARTMENT | 5.00 | 0.25 | 5.00 | 0.25 |
G S1 APARTMENT | 3.00 | 0.00 | 3.00 | 0.00 |
G S2 APARTMENT | 2.50 | 0.00 | 2.50 | 0.00 |
M SW APARTMENT | 1.75 | 0.00 | 1.75 | 0.00 |
M NW APARTMENT | 2.75 | 0.00 | 2.75 | 0.00 |
M SE APARTMENT | 1.25 | 0.00 | 1.25 | 0.00 |
M NE APARTMENT | 5.50 | 0.00 | 5.50 | 0.00 |
M N1 APARTMENT | 3.75 | 0.00 | 3.75 | 0.00 |
M N2 APARTMENT | 3.75 | 0.00 | 3.75 | 0.00 |
M S1 APARTMENT | 1.25 | 0.00 | 1.25 | 0.00 |
M S2 APARTMENT | 2.25 | 0.00 | 2.25 | 0.00 |
T SW APARTMENT | 2.50 | 0.00 | 2.50 | 0.00 |
T NW APARTMENT | 3.50 | 0.00 | 3.50 | 0.00 |
T SE APARTMENT | 2.25 | 0.00 | 2.25 | 0.00 |
T NE APARTMENT | 4.00 | 0.00 | 4.00 | 0.00 |
T N1 APARTMENT | 1.25 | 0.00 | 1.25 | 0.00 |
T N2 APARTMENT | 0.75 | 0.00 | 0.75 | 0.00 |
T S1 APARTMENT | 1.50 | 0.00 | 1.50 | 0.00 |
T S2 APARTMENT | 1.50 | 0.00 | 1.50 | 0.00 |
T CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 56.00 | 12.50 | 43.00 | 0.75 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:16
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.366 | 0.207 | 0.000 | 0.075 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.207 | 0.000 | 0.074 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.519 | 0.235 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.207 | 0.000 | 0.074 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.125 | 0.000 | 0.074 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.125 | 0.000 | 0.074 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.125 | 0.000 | 0.074 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.125 | 0.000 | 0.075 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.298 | 0.000 | 0.094 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.297 | 0.000 | 0.094 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.298 | 0.000 | 0.094 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.297 | 0.000 | 0.094 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.179 | 0.000 | 0.094 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.179 | 0.000 | 0.094 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.180 | 0.000 | 0.094 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.354 | 0.180 | 0.000 | 0.094 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.393 | 0.000 | 0.112 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.393 | 0.000 | 0.112 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.393 | 0.000 | 0.112 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.393 | 0.000 | 0.112 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.237 | 0.000 | 0.112 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.237 | 0.000 | 0.112 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.237 | 0.000 | 0.112 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.353 | 0.237 | 0.000 | 0.112 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
G SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.352 | 0.000 | 0.000 | 0.000 |
G NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
OFFICE | 0.94 | 1.00 | 268.97 | 0.498 | 0.000 | 0.000 | 0.000 |
G NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
G N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
G N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
G S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
G S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
M SW APARTMENT | 1.71 | 2.50 | 268.97 | 1.358 | 0.000 | 0.000 | 0.000 |
M NW APARTMENT | 1.71 | 2.50 | 268.97 | 1.358 | 0.000 | 0.000 | 0.000 |
M SE APARTMENT | 1.71 | 2.50 | 268.97 | 1.358 | 0.000 | 0.000 | 0.000 |
M NE APARTMENT | 1.71 | 2.50 | 268.97 | 1.358 | 0.000 | 0.000 | 0.000 |
M N1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.358 | 0.000 | 0.000 | 0.000 |
M N2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.358 | 0.000 | 0.000 | 0.000 |
M S1 APARTMENT | 1.71 | 2.50 | 268.97 | 1.358 | 0.000 | 0.000 | 0.000 |
M S2 APARTMENT | 1.71 | 2.50 | 268.97 | 1.357 | 0.000 | 0.000 | 0.000 |
T SW APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
T NW APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
T SE APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
T NE APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
T N1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
T N2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
T S1 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
T S2 APARTMENT | 1.71 | 2.50 | 268.97 | 0.340 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:16
Surfaces by ClassTotal | Outdoors | |
Wall | 126 | 42 |
Floor | 27 | 9 |
Roof | 27 | 9 |
Internal Mass | 24 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 39 | 39 |
Door | 0 | 0 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 24 |
Conditioned Zones | 24 |
Unconditioned Zones | 3 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 1385 |
Defaulted Fields | 439 |
Fields with Defaults | 3704 |
Autosized Fields | 336 |
Autosizable Fields | 454 |
Autocalculated Fields | 247 |
Autocalculatable Fields | 424 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2015-09-09 18:47:16
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum | Electricity Maximum Value [W] | Timestamp of Maximum | |
Electricity:Facility | 1434.87 | 20423.92 | 01-JAN-03:15 | 89053.59 | 16-JUL-18:00 |
Electricity:Building | 636.11 | 10559.61 | 01-JAN-03:15 | 31610.87 | 01-JAN-18:15 |
Electricity:Zone:G SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity | 118.46 | 2466.75 | 01-JAN-00:15 | 5482.59 | 01-JAN-19:15 |
InteriorLights:Electricity:Zone:G SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
GeneralLights:InteriorLights:Electricity | 96.36 | 2205.67 | 01-JAN-00:15 | 4426.44 | 01-JAN-19:15 |
Electricity:Zone:G NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:OFFICE | 35.93 | 610.39 | 01-JAN-00:15 | 2669.36 | 02-JAN-08:15 |
InteriorLights:Electricity:Zone:OFFICE | 26.45 | 416.15 | 01-JAN-00:15 | 2080.74 | 02-JAN-08:15 |
Electricity:Zone:G NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:G S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:M SW APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SW APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M NW APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NW APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M SE APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M SE APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M NE APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M NE APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M N1 APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N1 APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M N2 APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M N2 APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M S1 APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S1 APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:M S2 APARTMENT | 26.60 | 460.32 | 01-JAN-03:15 | 1352.36 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:M S2 APARTMENT | 2.17 | 12.97 | 01-JAN-00:15 | 207.54 | 01-JAN-19:15 |
Electricity:Zone:T SW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NW APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NW APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T SE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T SE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T NE APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T NE APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T N2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T N2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S1 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S1 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:T S2 APARTMENT | 13.30 | 230.16 | 01-JAN-03:15 | 676.18 | 01-JAN-18:15 |
InteriorLights:Electricity:Zone:T S2 APARTMENT | 1.09 | 6.49 | 01-JAN-00:15 | 103.77 | 01-JAN-19:15 |
Electricity:Zone:G CORRIDOR | 144.16 | 1427.03 | 01-JAN-00:15 | 8651.76 | 01-JAN-07:15 |
InteriorLights:Electricity:Zone:G CORRIDOR | 14.58 | 462.39 | 01-JAN-00:15 | 462.39 | 01-JAN-00:15 |
Electricity:Zone:M CORRIDOR | 29.16 | 924.77 | 01-JAN-00:15 | 924.77 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:M CORRIDOR | 29.16 | 924.77 | 01-JAN-00:15 | 924.77 | 01-JAN-00:15 |
Electricity:Zone:T CORRIDOR | 14.58 | 462.39 | 01-JAN-00:15 | 462.39 | 01-JAN-00:15 |
InteriorLights:Electricity:Zone:T CORRIDOR | 14.58 | 462.39 | 01-JAN-00:15 | 462.39 | 01-JAN-00:15 |
GeneralLights-plugin:InteriorLights:Electricity | 22.11 | 261.08 | 01-JAN-00:15 | 1411.40 | 02-JAN-16:15 |
InteriorEquipment:Electricity | 517.65 | 8092.87 | 01-JAN-03:15 | 26730.99 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
MiscPlug:InteriorEquipment:Electricity | 517.65 | 8092.87 | 01-JAN-03:15 | 26730.99 | 02-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:OFFICE | 9.48 | 194.25 | 01-JAN-00:15 | 588.62 | 02-JAN-08:15 |
InteriorEquipment:Electricity:Zone:G NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NW APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M SE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M NE APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M N2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S1 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:M S2 APARTMENT | 24.43 | 447.35 | 01-JAN-03:15 | 1177.25 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NW APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T SE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T NE APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T N2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S1 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:T S2 APARTMENT | 12.21 | 223.68 | 01-JAN-03:15 | 588.62 | 01-JAN-17:15 |
InteriorEquipment:Electricity:Zone:G CORRIDOR | 129.57 | 964.65 | 01-JAN-00:15 | 8189.37 | 01-JAN-07:15 |
Electricity:Plant | 411.79 | 0.00 | 01-JAN-00:15 | 32730.25 | 20-FEB-07:30 |
WaterSystems:Electricity | 411.79 | 0.00 | 01-JAN-00:15 | 32730.25 | 20-FEB-07:30 |
Water Heater:WaterSystems:Electricity | 411.79 | 0.00 | 01-JAN-00:15 | 32730.25 | 20-FEB-07:30 |
Fans:Electricity | 230.57 | 7311.31 | 01-JAN-00:45 | 7311.31 | 01-JAN-06:30 |
Fans:Electricity:Zone:G SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:G S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:M S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NW APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T SE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T NE APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T N2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S1 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Fans:Electricity:Zone:T S2 APARTMENT | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityPurchased:Facility | 1434.87 | 20423.92 | 01-JAN-03:15 | 89053.59 | 16-JUL-18:00 |
ElectricityPurchased:Plant | 1434.87 | 20423.92 | 01-JAN-03:15 | 89053.59 | 16-JUL-18:00 |
Cogeneration:ElectricityPurchased | 1434.87 | 20423.92 | 01-JAN-03:15 | 89053.59 | 16-JUL-18:00 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
ElectricityNet:Facility | 1434.87 | 20423.92 | 01-JAN-03:15 | 89053.59 | 16-JUL-18:00 |
ElectricityNet:Plant | 1434.87 | 20423.92 | 01-JAN-03:15 | 89053.59 | 16-JUL-18:00 |
Cogeneration:ElectricityNet | 1434.87 | 20423.92 | 01-JAN-03:15 | 89053.59 | 16-JUL-18:00 |
ExteriorLights:Electricity | 40.07 | 0.00 | 01-JAN-07:30 | 2553.00 | 01-JAN-00:15 |
General:ExteriorLights:Electricity | 40.07 | 0.00 | 01-JAN-07:30 | 2553.00 | 01-JAN-00:15 |
Electricity:HVAC | 346.89 | 7311.31 | 01-JAN-00:45 | 38808.10 | 19-JUL-15:15 |
General:Fans:Electricity | 230.57 | 7311.31 | 01-JAN-00:45 | 7311.31 | 01-JAN-06:30 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:Electricity | 116.32 | 0.00 | 01-JAN-00:15 | 31496.79 | 19-JUL-15:15 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum | Gas Maximum Value [W] | Timestamp of Maximum | |
Gas:Facility | 574.98 | 0.00 | 10-MAR-15:45 | 159144.11 | 27-JAN-01:00 |
Gas:HVAC | 574.98 | 0.00 | 10-MAR-15:45 | 159144.11 | 27-JAN-01:00 |
Heating:Gas | 574.98 | 0.00 | 10-MAR-15:45 | 159144.11 | 27-JAN-01:00 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum | Cooling Maximum Value [W] | Timestamp of Maximum | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
Water:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:Water | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Facility | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
MainsWater:Plant | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Water Heater:WaterSystems:MainsWater | 1874.72 | 0.00 | 01-JAN-02:15 | 0.00 | 01-JAN-07:15 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum | Maximum Value [kg/s] | Timestamp of Maximum | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:15 | 0.000 | 01-JAN-00:15 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum | Maximum Value [m3/s] | Timestamp of Maximum | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum | Maximum Value [L] | Timestamp of Maximum | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum | Maximum Value [W] | Timestamp of Maximum | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Facility | 1554.90 | 1590.43 | 24-APR-17:00 | 222035.64 | 27-JAN-01:00 |
EnergyTransfer:Building | 619.25 | 1575.53 | 13-MAY-15:00 | 94720.35 | 27-JAN-01:00 |
EnergyTransfer:Zone:G SW APARTMENT | 16.00 | 0.02 | 12-OCT-12:30 | 3011.11 | 27-JAN-01:00 |
Heating:EnergyTransfer | 270.81 | 0.00 | 11-FEB-17:00 | 94720.35 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:G SW APARTMENT | 9.24 | 0.00 | 10-JAN-11:00 | 3011.11 | 27-JAN-01:00 |
Cooling:EnergyTransfer | 348.44 | 0.00 | 02-JAN-07:30 | 70049.02 | 19-JUL-15:15 |
Cooling:EnergyTransfer:Zone:G SW APARTMENT | 6.75 | 0.00 | 01-JAN-00:15 | 1962.61 | 27-SEP-15:15 |
EnergyTransfer:Zone:G NW APARTMENT | 16.90 | 0.05 | 10-OCT-19:45 | 3069.04 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:G NW APARTMENT | 11.70 | 0.00 | 11-FEB-14:30 | 3069.04 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:G NW APARTMENT | 5.20 | 0.00 | 01-JAN-00:15 | 1841.13 | 05-JUL-17:30 |
EnergyTransfer:Zone:OFFICE | 22.91 | 0.00 | 30-APR-06:45 | 4537.37 | 16-JUL-09:45 |
Heating:EnergyTransfer:Zone:OFFICE | 2.84 | 0.00 | 01-JAN-00:15 | 4040.50 | 29-JAN-07:15 |
Cooling:EnergyTransfer:Zone:OFFICE | 20.07 | 0.00 | 02-JAN-07:30 | 4537.37 | 16-JUL-09:45 |
EnergyTransfer:Zone:G NE APARTMENT | 16.86 | 0.04 | 19-APR-01:30 | 3045.68 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:G NE APARTMENT | 11.52 | 0.00 | 11-FEB-16:15 | 3045.68 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:G NE APARTMENT | 5.34 | 0.00 | 01-JAN-00:15 | 1476.16 | 17-JUL-16:15 |
EnergyTransfer:Zone:G N1 APARTMENT | 10.85 | 0.01 | 15-APR-02:00 | 1906.80 | 27-JAN-08:15 |
Heating:EnergyTransfer:Zone:G N1 APARTMENT | 6.39 | 0.00 | 11-FEB-15:15 | 1906.80 | 27-JAN-08:15 |
Cooling:EnergyTransfer:Zone:G N1 APARTMENT | 4.46 | 0.00 | 01-JAN-00:15 | 1087.80 | 18-JUL-17:30 |
EnergyTransfer:Zone:G N2 APARTMENT | 10.85 | 0.02 | 30-APR-04:15 | 1902.83 | 27-JAN-08:15 |
Heating:EnergyTransfer:Zone:G N2 APARTMENT | 6.39 | 0.00 | 11-FEB-15:15 | 1902.83 | 27-JAN-08:15 |
Cooling:EnergyTransfer:Zone:G N2 APARTMENT | 4.46 | 0.00 | 01-JAN-00:15 | 1078.95 | 18-JUL-17:30 |
EnergyTransfer:Zone:G S1 APARTMENT | 10.50 | 0.00 | 21-APR-19:45 | 1802.53 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:G S1 APARTMENT | 4.33 | 0.00 | 01-JAN-17:15 | 1802.53 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:G S1 APARTMENT | 6.18 | 0.00 | 01-JAN-00:15 | 1297.96 | 28-SEP-12:30 |
EnergyTransfer:Zone:G S2 APARTMENT | 11.29 | 0.01 | 07-OCT-00:30 | 1914.10 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:G S2 APARTMENT | 4.85 | 0.00 | 05-JAN-12:45 | 1914.10 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:G S2 APARTMENT | 6.44 | 0.00 | 01-JAN-00:15 | 1310.12 | 28-SEP-12:30 |
EnergyTransfer:Zone:M SW APARTMENT | 41.97 | 0.05 | 10-OCT-13:30 | 6702.57 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:M SW APARTMENT | 13.82 | 0.00 | 01-JAN-16:15 | 6702.57 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:M SW APARTMENT | 28.15 | 0.00 | 01-JAN-00:15 | 5451.13 | 27-SEP-15:15 |
EnergyTransfer:Zone:M NW APARTMENT | 41.73 | 0.02 | 10-JUN-10:15 | 6706.55 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:M NW APARTMENT | 19.75 | 0.00 | 10-FEB-17:45 | 6706.55 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:M NW APARTMENT | 21.98 | 0.00 | 01-JAN-00:15 | 5022.98 | 05-JUL-17:30 |
EnergyTransfer:Zone:M SE APARTMENT | 42.18 | 0.03 | 09-NOV-02:30 | 6634.16 | 26-JAN-22:15 |
Heating:EnergyTransfer:Zone:M SE APARTMENT | 13.61 | 0.00 | 01-JAN-16:15 | 6634.16 | 26-JAN-22:15 |
Cooling:EnergyTransfer:Zone:M SE APARTMENT | 28.57 | 0.00 | 01-JAN-00:15 | 4951.54 | 16-APR-13:15 |
EnergyTransfer:Zone:M NE APARTMENT | 42.02 | 0.07 | 25-OCT-09:30 | 6602.16 | 26-JAN-20:00 |
Heating:EnergyTransfer:Zone:M NE APARTMENT | 19.49 | 0.00 | 10-FEB-18:15 | 6602.16 | 26-JAN-20:00 |
Cooling:EnergyTransfer:Zone:M NE APARTMENT | 22.53 | 0.00 | 01-JAN-00:15 | 4326.85 | 19-JUL-14:45 |
EnergyTransfer:Zone:M N1 APARTMENT | 27.93 | 0.25 | 08-DEC-20:00 | 3751.84 | 26-JAN-22:45 |
Heating:EnergyTransfer:Zone:M N1 APARTMENT | 7.54 | 0.00 | 01-JAN-16:15 | 3751.84 | 26-JAN-22:45 |
Cooling:EnergyTransfer:Zone:M N1 APARTMENT | 20.39 | 0.00 | 01-JAN-00:15 | 3186.78 | 19-JUL-15:15 |
EnergyTransfer:Zone:M N2 APARTMENT | 27.94 | 0.14 | 18-MAR-18:30 | 3753.91 | 26-JAN-22:30 |
Heating:EnergyTransfer:Zone:M N2 APARTMENT | 7.54 | 0.00 | 01-JAN-16:15 | 3753.91 | 26-JAN-22:30 |
Cooling:EnergyTransfer:Zone:M N2 APARTMENT | 20.40 | 0.00 | 01-JAN-00:15 | 3181.22 | 19-JUL-15:15 |
EnergyTransfer:Zone:M S1 APARTMENT | 32.33 | 0.26 | 25-FEB-19:45 | 3909.04 | 26-SEP-12:45 |
Heating:EnergyTransfer:Zone:M S1 APARTMENT | 3.82 | 0.00 | 01-JAN-09:00 | 3758.15 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:M S1 APARTMENT | 28.51 | 0.00 | 01-JAN-00:15 | 3909.04 | 26-SEP-12:45 |
EnergyTransfer:Zone:M S2 APARTMENT | 32.34 | 0.40 | 06-FEB-09:45 | 3918.70 | 26-SEP-12:45 |
Heating:EnergyTransfer:Zone:M S2 APARTMENT | 3.82 | 0.00 | 01-JAN-09:00 | 3759.28 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:M S2 APARTMENT | 28.52 | 0.00 | 01-JAN-00:15 | 3918.70 | 26-SEP-12:45 |
EnergyTransfer:Zone:T SW APARTMENT | 31.18 | 0.00 | 25-MAY-22:30 | 5388.95 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:T SW APARTMENT | 17.96 | 0.00 | 10-JAN-11:15 | 5388.95 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:T SW APARTMENT | 13.22 | 0.00 | 01-JAN-00:15 | 3671.67 | 19-JUL-15:00 |
EnergyTransfer:Zone:T NW APARTMENT | 32.07 | 0.06 | 23-OCT-18:15 | 5367.89 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:T NW APARTMENT | 21.34 | 0.00 | 11-FEB-13:45 | 5367.89 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:T NW APARTMENT | 10.73 | 0.00 | 01-JAN-00:15 | 3454.93 | 19-JUL-15:15 |
EnergyTransfer:Zone:T SE APARTMENT | 30.92 | 0.01 | 04-NOV-06:45 | 5346.74 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:T SE APARTMENT | 17.70 | 0.00 | 10-JAN-10:45 | 5346.74 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:T SE APARTMENT | 13.22 | 0.00 | 01-JAN-00:15 | 3375.93 | 16-APR-13:15 |
EnergyTransfer:Zone:T NE APARTMENT | 31.80 | 0.01 | 24-MAY-03:30 | 5288.46 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:T NE APARTMENT | 21.02 | 0.00 | 11-FEB-13:30 | 5288.46 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:T NE APARTMENT | 10.78 | 0.00 | 01-JAN-00:15 | 3095.85 | 19-JUL-15:00 |
EnergyTransfer:Zone:T N1 APARTMENT | 22.33 | 0.05 | 19-APR-05:15 | 3657.95 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:T N1 APARTMENT | 13.05 | 0.00 | 11-FEB-12:30 | 3657.95 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:T N1 APARTMENT | 9.28 | 0.00 | 01-JAN-00:15 | 2393.31 | 19-JUL-15:15 |
EnergyTransfer:Zone:T N2 APARTMENT | 22.33 | 0.02 | 11-MAR-09:15 | 3658.07 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:T N2 APARTMENT | 13.04 | 0.00 | 11-FEB-12:30 | 3658.07 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:T N2 APARTMENT | 9.28 | 0.00 | 01-JAN-00:15 | 2385.46 | 19-JUL-15:15 |
EnergyTransfer:Zone:T S1 APARTMENT | 22.01 | 0.01 | 22-SEP-01:15 | 3693.83 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:T S1 APARTMENT | 10.03 | 0.00 | 05-JAN-13:45 | 3693.83 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:T S1 APARTMENT | 11.99 | 0.00 | 01-JAN-00:15 | 2788.42 | 16-APR-13:30 |
EnergyTransfer:Zone:T S2 APARTMENT | 22.02 | 0.05 | 23-FEB-18:30 | 3694.50 | 27-JAN-01:00 |
Heating:EnergyTransfer:Zone:T S2 APARTMENT | 10.03 | 0.00 | 05-JAN-13:45 | 3694.50 | 27-JAN-01:00 |
Cooling:EnergyTransfer:Zone:T S2 APARTMENT | 12.00 | 0.00 | 01-JAN-00:15 | 2793.16 | 16-APR-13:30 |
EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:T CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:G CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Heating:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
Cooling:EnergyTransfer:Zone:M CORRIDOR | 0.00 | 0.00 | 01-JAN-00:15 | 0.00 | 01-JAN-00:15 |
EnergyTransfer:HVAC | 935.66 | 0.00 | 26-MAR-18:30 | 127315.28 | 27-JAN-01:00 |
HeatingCoils:EnergyTransfer | 459.98 | 0.00 | 10-MAR-15:45 | 127315.28 | 27-JAN-01:00 |
CoolingCoils:EnergyTransfer | 475.67 | 0.00 | 01-JAN-00:15 | 122318.41 | 19-JUL-15:15 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:16
Annual Building Sensible Heat Gain ComponentsHVAC Input Sensible Air Heating [GJ] | HVAC Input Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
G SW APARTMENT | 9.244 | -6.751 | 0.000 | 0.000 | 3.865 | 1.087 | 12.213 | 12.358 | 0.000 | 0.264 | 0.000 | 0.000 | -7.719 | 0.000 | -8.489 | -16.071 |
G NW APARTMENT | 11.701 | -5.197 | 0.000 | 0.000 | 3.877 | 1.087 | 12.213 | 6.606 | 0.000 | 0.263 | 0.000 | 0.000 | -8.162 | 0.000 | -8.410 | -13.977 |
OFFICE | 2.839 | -20.070 | 0.000 | 0.000 | 0.530 | 26.452 | 9.482 | 12.299 | 0.000 | 0.168 | 0.001 | 0.000 | -7.451 | 0.000 | -7.607 | -16.641 |
G NE APARTMENT | 11.519 | -5.342 | 0.000 | 0.000 | 3.884 | 1.087 | 12.213 | 6.636 | 0.000 | 0.263 | 0.000 | 0.000 | -7.968 | 0.000 | -8.394 | -13.897 |
G N1 APARTMENT | 6.391 | -4.455 | 0.000 | 0.000 | 3.883 | 1.087 | 12.213 | 2.570 | 0.000 | 0.173 | 0.000 | 0.000 | -5.107 | 0.000 | -5.326 | -11.428 |
G N2 APARTMENT | 6.388 | -4.461 | 0.000 | 0.000 | 3.884 | 1.087 | 12.213 | 2.570 | 0.000 | 0.173 | 0.000 | 0.000 | -5.106 | 0.000 | -5.326 | -11.421 |
G S1 APARTMENT | 4.327 | -6.177 | 0.000 | 0.000 | 3.865 | 1.087 | 12.213 | 8.365 | 0.000 | 0.172 | 0.000 | 0.000 | -4.673 | 0.000 | -5.411 | -13.768 |
G S2 APARTMENT | 4.848 | -6.444 | 0.000 | 0.000 | 3.863 | 1.087 | 12.213 | 8.360 | 0.000 | 0.172 | 0.000 | 0.000 | -4.671 | 0.000 | -5.420 | -14.007 |
M SW APARTMENT | 13.819 | -28.153 | 0.000 | 0.000 | 3.781 | 1.087 | 12.213 | 11.959 | 0.000 | 0.373 | 5.643 | 0.000 | -8.308 | 0.000 | -12.413 | -0.000 |
M NW APARTMENT | 19.750 | -21.975 | 0.000 | 0.000 | 3.809 | 1.087 | 12.213 | 6.292 | 0.000 | 0.371 | 0.000 | 0.000 | -8.712 | 0.000 | -12.260 | -0.575 |
M SE APARTMENT | 13.606 | -28.571 | 0.000 | 0.000 | 3.785 | 1.087 | 12.213 | 12.043 | 0.000 | 0.373 | 6.034 | 0.000 | -8.162 | 0.000 | -12.406 | -0.000 |
M NE APARTMENT | 19.490 | -22.525 | 0.000 | 0.000 | 3.816 | 1.087 | 12.213 | 6.316 | 0.000 | 0.371 | 0.000 | 0.000 | -8.495 | 0.000 | -12.235 | -0.037 |
M N1 APARTMENT | 7.542 | -20.392 | 0.000 | 0.000 | 3.802 | 1.087 | 12.213 | 2.374 | 0.000 | 0.239 | 6.442 | 0.000 | -5.505 | 0.000 | -7.802 | -0.001 |
M N2 APARTMENT | 7.543 | -20.396 | 0.000 | 0.000 | 3.802 | 1.087 | 12.213 | 2.374 | 0.000 | 0.239 | 6.442 | 0.000 | -5.503 | 0.000 | -7.800 | -0.001 |
M S1 APARTMENT | 3.821 | -28.509 | 0.000 | 0.000 | 3.765 | 1.087 | 12.213 | 8.106 | 0.000 | 0.241 | 12.268 | 0.000 | -5.057 | 0.000 | -7.934 | -0.000 |
M S2 APARTMENT | 3.823 | -28.517 | 0.000 | 0.000 | 3.765 | 1.087 | 12.213 | 8.105 | 0.000 | 0.241 | 12.274 | 0.000 | -5.056 | 0.000 | -7.935 | -0.000 |
T SW APARTMENT | 17.957 | -13.219 | 0.000 | 0.000 | 3.827 | 1.087 | 12.213 | 11.855 | 0.000 | 0.495 | 0.000 | 0.000 | -7.933 | 0.000 | -16.026 | -10.255 |
T NW APARTMENT | 21.340 | -10.729 | 0.000 | 0.000 | 3.846 | 1.087 | 12.213 | 6.222 | 0.000 | 0.492 | 0.000 | 0.000 | -8.352 | 0.000 | -15.876 | -10.242 |
T SE APARTMENT | 17.697 | -13.220 | 0.000 | 0.000 | 3.831 | 1.087 | 12.213 | 11.953 | 0.000 | 0.495 | 0.000 | 0.000 | -7.800 | 0.000 | -16.029 | -10.226 |
T NE APARTMENT | 21.020 | -10.777 | 0.000 | 0.000 | 3.854 | 1.087 | 12.213 | 6.262 | 0.000 | 0.492 | 0.000 | 0.000 | -8.151 | 0.000 | -15.856 | -10.143 |
T N1 APARTMENT | 13.046 | -9.284 | 0.000 | 0.000 | 3.843 | 1.087 | 12.213 | 2.362 | 0.000 | 0.319 | 0.000 | 0.000 | -5.244 | 0.000 | -10.002 | -8.340 |
T N2 APARTMENT | 13.045 | -9.285 | 0.000 | 0.000 | 3.844 | 1.087 | 12.213 | 2.361 | 0.000 | 0.319 | 0.000 | 0.000 | -5.242 | 0.000 | -10.003 | -8.338 |
T S1 APARTMENT | 10.025 | -11.987 | 0.000 | 0.000 | 3.815 | 1.087 | 12.213 | 8.054 | 0.000 | 0.322 | 0.000 | 0.000 | -4.832 | 0.000 | -10.150 | -8.546 |
T S2 APARTMENT | 10.026 | -11.997 | 0.000 | 0.000 | 3.815 | 1.087 | 12.213 | 8.053 | 0.000 | 0.322 | 0.000 | 0.000 | -4.831 | 0.000 | -10.151 | -8.536 |
T CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 14.582 | 0.000 | 0.100 | 0.000 | 0.023 | 0.000 | 0.000 | -0.989 | 0.000 | -2.646 | -11.070 |
G CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 14.582 | 6.479 | 0.366 | 0.000 | 0.569 | 13.392 | 0.000 | -2.551 | 0.000 | -32.837 | -0.000 |
M CORRIDOR | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 14.582 | 0.000 | 0.102 | 0.000 | 0.023 | 0.000 | 0.000 | -1.077 | 0.000 | -2.176 | -11.453 |
Total Facility | 270.809 | -348.434 | 0.000 | 0.000 | 88.648 | 95.189 | 296.854 | 175.023 | 0.000 | 7.967 | 62.496 | 0.000 | -162.657 | 0.000 | -276.922 | -208.974 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 27-SEP-15:15 | 0.00 | -1962.27 | 0.00 | 0.00 | 48.90 | 45.40 | 470.90 | 2527.77 | 0.00 | 182.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1313.55 |
G NW APARTMENT | 05-JUL-17:25 | 0.00 | -1841.44 | 0.00 | 0.00 | 141.82 | 87.56 | 588.62 | 1839.86 | 0.00 | 212.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1028.93 |
OFFICE | 07-AUG-06:01 | 0.00 | -7389.19 | 0.00 | 0.00 | 0.00 | 416.15 | 294.31 | 1036.29 | 0.00 | 0.00 | 5745.23 | 0.00 | 0.00 | 0.00 | -102.79 | 0.00 |
G NE APARTMENT | 17-JUL-16:15 | 0.00 | -1478.00 | 0.00 | 0.00 | 84.77 | 64.86 | 588.62 | 758.49 | 0.00 | 275.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -294.43 |
G N1 APARTMENT | 18-JUL-17:30 | 0.00 | -1088.47 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 441.96 | 0.00 | 138.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -310.47 |
G N2 APARTMENT | 18-JUL-17:30 | 0.00 | -1079.43 | 0.00 | 0.00 | 141.81 | 87.56 | 588.62 | 442.10 | 0.00 | 138.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -319.65 |
G S1 APARTMENT | 28-SEP-12:30 | 0.00 | -1297.94 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2161.04 | 0.00 | 46.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1352.15 |
G S2 APARTMENT | 28-SEP-12:30 | 0.00 | -1310.11 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2160.81 | 0.00 | 46.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1339.75 |
M SW APARTMENT | 27-SEP-15:15 | 0.00 | -5450.32 | 0.00 | 0.00 | 48.90 | 45.40 | 470.90 | 2506.43 | 0.00 | 262.02 | 2116.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NW APARTMENT | 05-JUL-17:10 | 0.00 | -5026.42 | 0.00 | 0.00 | 141.83 | 87.56 | 588.62 | 1813.53 | 0.00 | 331.61 | 2063.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M SE APARTMENT | 16-APR-13:15 | 0.00 | -4951.11 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1932.18 | 0.00 | 329.15 | 2253.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M NE APARTMENT | 19-JUL-14:45 | 0.00 | -4327.38 | 0.00 | 0.00 | 40.76 | 22.70 | 400.26 | 955.38 | 0.00 | 513.79 | 2394.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N1 APARTMENT | 19-JUL-15:15 | 0.00 | -3187.18 | 0.00 | 0.00 | 48.90 | 45.40 | 470.90 | 527.11 | 0.00 | 318.50 | 1776.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M N2 APARTMENT | 19-JUL-15:15 | 0.00 | -3181.62 | 0.00 | 0.00 | 48.90 | 45.40 | 470.90 | 527.13 | 0.00 | 318.50 | 1770.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S1 APARTMENT | 26-SEP-12:45 | 0.00 | -3909.39 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2094.24 | 0.00 | 123.08 | 1249.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M S2 APARTMENT | 26-SEP-12:45 | 0.00 | -3919.06 | 0.00 | 0.00 | 40.75 | 12.97 | 388.49 | 2094.19 | 0.00 | 123.07 | 1259.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SW APARTMENT | 19-JUL-15:00 | 0.00 | -3672.27 | 0.00 | 0.00 | 40.76 | 22.70 | 400.26 | 1806.61 | 0.00 | 752.10 | 649.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NW APARTMENT | 19-JUL-15:15 | 0.00 | -3455.51 | 0.00 | 0.00 | 48.91 | 45.40 | 470.90 | 1612.40 | 0.00 | 695.90 | 582.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T SE APARTMENT | 16-APR-13:15 | 0.00 | -3375.66 | 0.00 | 0.00 | 40.76 | 12.97 | 382.60 | 1892.76 | 0.00 | 432.39 | 614.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T NE APARTMENT | 19-JUL-15:00 | 0.00 | -3096.48 | 0.00 | 0.00 | 40.76 | 22.70 | 400.26 | 893.62 | 0.00 | 752.13 | 987.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N1 APARTMENT | 19-JUL-15:15 | 0.00 | -2393.71 | 0.00 | 0.00 | 48.91 | 45.40 | 470.90 | 514.01 | 0.00 | 419.70 | 894.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T N2 APARTMENT | 19-JUL-15:15 | 0.00 | -2385.87 | 0.00 | 0.00 | 48.91 | 45.40 | 470.90 | 514.10 | 0.00 | 419.70 | 886.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S1 APARTMENT | 16-APR-13:30 | 0.00 | -2788.12 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1536.42 | 0.00 | 267.44 | 547.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T S2 APARTMENT | 16-APR-13:30 | 0.00 | -2792.87 | 0.00 | 0.00 | 40.75 | 12.97 | 382.60 | 1536.33 | 0.00 | 267.44 | 552.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 19-JUL-15:15 | 0.00 | -70060.71 | 0.00 | 0.00 | 1191.87 | 4512.09 | 11708.34 | 22777.56 | 0.00 | 10959.78 | 18911.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Time of Peak | HVAC Input Sensible Air Heating [W] | HVAC Input Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
G SW APARTMENT | 27-JAN-01:00 | 3011.09 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1068.79 | 0.00 | -1878.89 | -524.44 |
G NW APARTMENT | 27-JAN-01:00 | 3069.02 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1090.20 | 0.00 | -1878.89 | -560.97 |
OFFICE | 19-MAR-06:01 | 6470.25 | 0.00 | 0.00 | 0.00 | 0.00 | 416.15 | 294.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -340.48 | 0.00 | -419.24 | -6420.99 |
G NE APARTMENT | 27-JAN-01:00 | 3045.66 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1073.78 | 0.00 | -1878.01 | -554.92 |
G N1 APARTMENT | 27-JAN-08:06 | 1907.79 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -588.77 | 0.00 | -990.55 | -810.40 |
G N2 APARTMENT | 27-JAN-08:06 | 1903.82 | 0.00 | 0.00 | 0.00 | 73.97 | 19.46 | 388.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -588.81 | 0.00 | -990.55 | -806.38 |
G S1 APARTMENT | 27-JAN-01:00 | 1802.52 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -640.33 | 0.00 | -1133.30 | -489.93 |
G S2 APARTMENT | 27-JAN-01:00 | 1914.09 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -638.74 | 0.00 | -1133.30 | -603.09 |
M SW APARTMENT | 27-JAN-01:00 | 6702.54 | 0.00 | 0.00 | 0.00 | 189.97 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1093.44 | 0.00 | -2691.48 | -3378.95 |
M NW APARTMENT | 27-JAN-01:00 | 6706.52 | 0.00 | 0.00 | 0.00 | 190.91 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1115.01 | 0.00 | -2681.28 | -3372.51 |
M SE APARTMENT | 26-JAN-22:06 | 6634.35 | 0.00 | 0.00 | 0.00 | 189.67 | 38.91 | 417.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1047.22 | 0.00 | -2729.35 | -3504.28 |
M NE APARTMENT | 26-JAN-20:00 | 6602.06 | 0.00 | 0.00 | 0.00 | 165.01 | 103.77 | 547.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1049.34 | 0.00 | -2781.06 | -3587.87 |
M N1 APARTMENT | 26-JAN-22:45 | 3752.38 | 0.00 | 0.00 | 0.00 | 189.67 | 38.91 | 417.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -669.92 | 0.00 | -1672.00 | -2056.97 |
M N2 APARTMENT | 26-JAN-22:28 | 3754.87 | 0.00 | 0.00 | 0.00 | 189.67 | 38.91 | 417.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -665.92 | 0.00 | -1659.72 | -2075.73 |
M S1 APARTMENT | 27-JAN-01:00 | 3758.13 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -655.16 | 0.00 | -1628.88 | -1935.13 |
M S2 APARTMENT | 27-JAN-01:00 | 3759.26 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -655.13 | 0.00 | -1628.83 | -1936.34 |
T SW APARTMENT | 27-JAN-01:00 | 5388.92 | 0.00 | 0.00 | 0.00 | 190.73 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1066.70 | 0.00 | -3549.69 | -1234.63 |
T NW APARTMENT | 27-JAN-01:00 | 5367.86 | 0.00 | 0.00 | 0.00 | 191.82 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1088.75 | 0.00 | -3537.19 | -1205.10 |
T SE APARTMENT | 27-JAN-01:00 | 5346.71 | 0.00 | 0.00 | 0.00 | 191.20 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1046.81 | 0.00 | -3544.20 | -1218.27 |
T NE APARTMENT | 27-JAN-01:00 | 5288.43 | 0.00 | 0.00 | 0.00 | 192.94 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1067.30 | 0.00 | -3525.00 | -1160.44 |
T N1 APARTMENT | 27-JAN-01:00 | 3657.93 | 0.00 | 0.00 | 0.00 | 189.81 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -663.65 | 0.00 | -2151.95 | -1303.51 |
T N2 APARTMENT | 27-JAN-01:00 | 3658.05 | 0.00 | 0.00 | 0.00 | 189.83 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -663.59 | 0.00 | -2151.76 | -1303.91 |
T S1 APARTMENT | 27-JAN-01:00 | 3693.82 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -639.11 | 0.00 | -2156.87 | -1358.88 |
T S2 APARTMENT | 27-JAN-01:00 | 3694.48 | 0.00 | 0.00 | 0.00 | 189.67 | 6.49 | 264.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -639.09 | 0.00 | -2156.84 | -1359.59 |
T CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
G CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
M CORRIDOR | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 27-JAN-01:00 | 94719.90 | 0.00 | 0.00 | 0.00 | 4376.24 | 1952.47 | 6334.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -21186.40 | 0.00 | -53109.71 | -33087.22 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:16
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | |
None |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
None |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
None |
Report: LEED Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:16
Sec1.1A-General InformationData | |
Weather File | Chicago Ohare Intl Ap IL USA TMY3 WMO#=725300 |
HDD and CDD data source | Weather File Stat |
Total gross floor area [m2] | 3134.61 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
G SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
OFFICE | 88.25 | 88.25 | 0.00 | 43.32 |
G NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
G S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
M S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NW APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T SE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T NE APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T N2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S1 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T S2 APARTMENT | 88.25 | 88.25 | 0.00 | 168.00 |
T CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
G CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
M CORRIDOR | 77.66 | 0.00 | 77.66 | 0.00 |
Totals | 3134.61 | 2823.98 | 310.64 |
Data | |
Number of hours heating loads not met | 43.00 |
Number of hours cooling loads not met | 0.75 |
Number of hours not met | 43.75 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Energy Use [GJ] | Additional Demand [W] | |
Interior Lighting | 118.46 | 4979.95 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 40.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Heating | 0.00 | 0.00 | 574.98 | 159144.11 | 0.00 | 0.00 |
Space Cooling | 116.32 | 25197.42 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Interior | 230.57 | 7311.31 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans-Parking Garage | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Service Water Heating | 411.79 | 24933.99 | 0.00 | 0.00 | 0.00 | 0.00 |
Receptacle Equipment | 517.65 | 26630.92 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting (process) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Industrial Process | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Elevators and Escalators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Line | 1434.87 | 574.98 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 517.65 | 1434.87 |
Natural Gas | 0.00 | 574.98 |
Additional | 0.00 | 0.00 |
Total | 517.65 | 2009.85 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting | 37.79 |
Space Heating | 0.00 |
Space Cooling | 37.11 |
Fans-Interior | 73.56 |
Service Water Heating | 131.37 |
Receptacle Equipment | 165.14 |
Miscellaneous | 12.78 |
Subtotal | 457.75 |
Natural Gas [MJ/m2] | |
Space Heating | 183.43 |
Service Water Heating | 0.00 |
Miscellaneous | 0.00 |
Subtotal | 183.43 |
Additional [MJ/m2] | |
Miscellaneous | 0.00 |
Subtotal | 0.00 |
Percent [%] | |
Interior Lighting | 5.89 |
Space Heating | 28.61 |
Space Cooling | 5.79 |
Fans-Interior | 11.47 |
Service Water Heating | 20.49 |
Receptacle Equipment | 25.76 |
Miscellaneous | 1.99 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:16
AirTerminal:SingleDuct:UncontrolledMaximum Air Flow Rate [m3/s] | |
G SW APARTMENT DIRECT AIR | 0.172009 |
G NW APARTMENT DIRECT AIR | 0.164224 |
OFFICE DIRECT AIR | 0.473040 |
G NE APARTMENT DIRECT AIR | 0.121716 |
G N1 APARTMENT DIRECT AIR | 0.093460 |
G N2 APARTMENT DIRECT AIR | 0.092384 |
G S1 APARTMENT DIRECT AIR | 0.109527 |
G S2 APARTMENT DIRECT AIR | 0.112617 |
M SW APARTMENT DIRECT AIR | 0.476554 |
M NW APARTMENT DIRECT AIR | 0.451255 |
M SE APARTMENT DIRECT AIR | 0.431834 |
M NE APARTMENT DIRECT AIR | 0.358272 |
M N1 APARTMENT DIRECT AIR | 0.271487 |
M N2 APARTMENT DIRECT AIR | 0.269674 |
M S1 APARTMENT DIRECT AIR | 0.317714 |
M S2 APARTMENT DIRECT AIR | 0.318933 |
T SW APARTMENT DIRECT AIR | 0.327225 |
T NW APARTMENT DIRECT AIR | 0.301043 |
T SE APARTMENT DIRECT AIR | 0.304151 |
T NE APARTMENT DIRECT AIR | 0.250270 |
T N1 APARTMENT DIRECT AIR | 0.194593 |
T N2 APARTMENT DIRECT AIR | 0.194666 |
T S1 APARTMENT DIRECT AIR | 0.245433 |
T S2 APARTMENT DIRECT AIR | 0.246216 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW MAIN BRANCH | 0.172009 |
SPLIT GNW MAIN BRANCH | 0.164224 |
SPLIT OFFICE MAIN BRANCH | 0.473040 |
SPLIT GNE MAIN BRANCH | 0.121716 |
SPLIT GN1 MAIN BRANCH | 0.093460 |
SPLIT GN2 MAIN BRANCH | 0.092384 |
SPLIT GS1 MAIN BRANCH | 0.109527 |
SPLIT GS2 MAIN BRANCH | 0.112617 |
SPLIT MSW MAIN BRANCH | 0.476554 |
SPLIT MNW MAIN BRANCH | 0.451255 |
SPLIT MSE MAIN BRANCH | 0.431834 |
SPLIT MNE MAIN BRANCH | 0.358272 |
SPLIT MN1 MAIN BRANCH | 0.271487 |
SPLIT MN2 MAIN BRANCH | 0.269674 |
SPLIT MS1 MAIN BRANCH | 0.317714 |
SPLIT MS2 MAIN BRANCH | 0.318933 |
SPLIT TSW MAIN BRANCH | 0.327225 |
SPLIT TNW MAIN BRANCH | 0.301043 |
SPLIT TSE MAIN BRANCH | 0.304151 |
SPLIT TNE MAIN BRANCH | 0.250270 |
SPLIT TN1 MAIN BRANCH | 0.194593 |
SPLIT TN2 MAIN BRANCH | 0.194666 |
SPLIT TS1 MAIN BRANCH | 0.245433 |
SPLIT TS2 MAIN BRANCH | 0.246216 |
Design Supply Air Flow Rate [m3/s] | |
SPLIT GSW | 0.172009 |
SPLIT GNW | 0.164224 |
SPLIT OFFICE | 0.473040 |
SPLIT GNE | 0.121716 |
SPLIT GN1 | 0.093460 |
SPLIT GN2 | 0.092384 |
SPLIT GS1 | 0.109527 |
SPLIT GS2 | 0.112617 |
SPLIT MSW | 0.476554 |
SPLIT MNW | 0.451255 |
SPLIT MSE | 0.431834 |
SPLIT MNE | 0.358272 |
SPLIT MN1 | 0.271487 |
SPLIT MN2 | 0.269674 |
SPLIT MS1 | 0.317714 |
SPLIT MS2 | 0.318933 |
SPLIT TSW | 0.327225 |
SPLIT TNW | 0.301043 |
SPLIT TSE | 0.304151 |
SPLIT TNE | 0.250270 |
SPLIT TN1 | 0.194593 |
SPLIT TN2 | 0.194666 |
SPLIT TS1 | 0.245433 |
SPLIT TS2 | 0.246216 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
SPLIT GSW OA CONTROLLER | 0.172009 | 0.026898 |
SPLIT GNW OA CONTROLLER | 0.164224 | 0.025953 |
SPLIT OFFICE OA CONTROLLER | 0.473040 | 0.038104 |
SPLIT GNE OA CONTROLLER | 0.121716 | 0.025953 |
SPLIT GN1 OA CONTROLLER | 0.093460 | 0.025953 |
SPLIT GN2 OA CONTROLLER | 0.092384 | 0.025953 |
SPLIT GS1 OA CONTROLLER | 0.109527 | 0.025953 |
SPLIT GS2 OA CONTROLLER | 0.112617 | 0.025953 |
SPLIT MSW OA CONTROLLER | 0.476554 | 0.051906 |
SPLIT MNW OA CONTROLLER | 0.451255 | 0.051906 |
SPLIT MSE OA CONTROLLER | 0.431834 | 0.051906 |
SPLIT MNE OA CONTROLLER | 0.358272 | 0.051906 |
SPLIT MN1 OA CONTROLLER | 0.271487 | 0.051906 |
SPLIT MN2 OA CONTROLLER | 0.269674 | 0.051906 |
SPLIT MS1 OA CONTROLLER | 0.317714 | 0.051906 |
SPLIT MS2 OA CONTROLLER | 0.318933 | 0.051906 |
SPLIT TSW OA CONTROLLER | 0.327225 | 0.025953 |
SPLIT TNW OA CONTROLLER | 0.301043 | 0.025953 |
SPLIT TSE OA CONTROLLER | 0.304151 | 0.025953 |
SPLIT TNE OA CONTROLLER | 0.250270 | 0.025953 |
SPLIT TN1 OA CONTROLLER | 0.194593 | 0.025953 |
SPLIT TN2 OA CONTROLLER | 0.194666 | 0.025953 |
SPLIT TS1 OA CONTROLLER | 0.245433 | 0.025953 |
SPLIT TS2 OA CONTROLLER | 0.246216 | 0.025953 |
Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity (gross) [W] | Rated Sensible Heat Ratio | |
SPLIT GSW COOLING COIL | 0.172009 | 3615.57 | 0.720539 |
SPLIT GNW COOLING COIL | 0.164224 | 3439.93 | 0.721548 |
SPLIT OFFICE COOLING COIL | 0.473040 | 8081.51 | 0.787235 |
SPLIT GNE COOLING COIL | 0.121716 | 2704.56 | 0.704894 |
SPLIT GN1 COOLING COIL | 0.093460 | 2189.20 | 0.690820 |
SPLIT GN2 COOLING COIL | 0.092384 | 2171.21 | 0.689958 |
SPLIT GS1 COOLING COIL | 0.109527 | 2557.94 | 0.691593 |
SPLIT GS2 COOLING COIL | 0.112617 | 2608.08 | 0.693794 |
SPLIT MSW COOLING COIL | 0.476554 | 9517.41 | 0.735737 |
SPLIT MNW COOLING COIL | 0.451255 | 9040.27 | 0.734790 |
SPLIT MSE COOLING COIL | 0.431834 | 8947.10 | 0.724742 |
SPLIT MNE COOLING COIL | 0.358272 | 7430.85 | 0.724431 |
SPLIT MN1 COOLING COIL | 0.271487 | 5855.25 | 0.713186 |
SPLIT MN2 COOLING COIL | 0.269674 | 5825.73 | 0.712721 |
SPLIT MS1 COOLING COIL | 0.317714 | 6846.57 | 0.713420 |
SPLIT MS2 COOLING COIL | 0.318933 | 6866.13 | 0.713696 |
SPLIT TSW COOLING COIL | 0.327225 | 6385.88 | 0.742858 |
SPLIT TNW COOLING COIL | 0.301043 | 5898.42 | 0.741617 |
SPLIT TSE COOLING COIL | 0.304151 | 6019.55 | 0.738509 |
SPLIT TNE COOLING COIL | 0.250270 | 5164.63 | 0.725918 |
SPLIT TN1 COOLING COIL | 0.194593 | 4082.32 | 0.721103 |
SPLIT TN2 COOLING COIL | 0.194666 | 4083.77 | 0.721108 |
SPLIT TS1 COOLING COIL | 0.245433 | 4896.49 | 0.736056 |
SPLIT TS2 COOLING COIL | 0.246216 | 4908.88 | 0.736257 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
SPLIT GSW FURNACE WITH DX COOLING | 0.172009 | 0.172009 | 0.172009 | 0.172009 | 4216.86 | 3615.57 | 1.00 |
SPLIT GNW FURNACE WITH DX COOLING | 0.164224 | 0.164224 | 0.164224 | 0.164224 | 4173.98 | 3439.93 | 1.00 |
SPLIT OFFICE FURNACE WITH DX COOLING | 0.473040 | 0.473040 | 0.473040 | 0.473040 | 6928.90 | 8081.51 | 1.00 |
SPLIT GNE FURNACE WITH DX COOLING | 0.121716 | 0.121716 | 0.121716 | 0.121716 | 4162.43 | 2704.56 | 1.00 |
SPLIT GN1 FURNACE WITH DX COOLING | 0.093460 | 0.093460 | 0.093460 | 0.093460 | 3123.07 | 2189.20 | 1.00 |
SPLIT GN2 FURNACE WITH DX COOLING | 0.092384 | 0.092384 | 0.092384 | 0.092384 | 3122.81 | 2171.21 | 1.00 |
SPLIT GS1 FURNACE WITH DX COOLING | 0.109527 | 0.109527 | 0.109527 | 0.109527 | 3122.83 | 2557.94 | 1.00 |
SPLIT GS2 FURNACE WITH DX COOLING | 0.112617 | 0.112617 | 0.112617 | 0.112617 | 3256.81 | 2608.08 | 1.00 |
SPLIT MSW FURNACE WITH DX COOLING | 0.476554 | 0.476554 | 0.476554 | 0.476554 | 8602.32 | 9517.41 | 1.00 |
SPLIT MNW FURNACE WITH DX COOLING | 0.451255 | 0.451255 | 0.451255 | 0.451255 | 8606.02 | 9040.27 | 1.00 |
SPLIT MSE FURNACE WITH DX COOLING | 0.431834 | 0.431834 | 0.431834 | 0.431834 | 8572.26 | 8947.10 | 1.00 |
SPLIT MNE FURNACE WITH DX COOLING | 0.358272 | 0.358272 | 0.358272 | 0.358272 | 8575.94 | 7430.85 | 1.00 |
SPLIT MN1 FURNACE WITH DX COOLING | 0.271487 | 0.271487 | 0.271487 | 0.271487 | 5907.26 | 5855.25 | 1.00 |
SPLIT MN2 FURNACE WITH DX COOLING | 0.269674 | 0.269674 | 0.269674 | 0.269674 | 5906.53 | 5825.73 | 1.00 |
SPLIT MS1 FURNACE WITH DX COOLING | 0.317714 | 0.317714 | 0.317714 | 0.317714 | 5905.97 | 6846.57 | 1.00 |
SPLIT MS2 FURNACE WITH DX COOLING | 0.318933 | 0.318933 | 0.318933 | 0.318933 | 5905.25 | 6866.13 | 1.00 |
SPLIT TSW FURNACE WITH DX COOLING | 0.327225 | 0.327225 | 0.327225 | 0.327225 | 6192.06 | 6385.88 | 1.00 |
SPLIT TNW FURNACE WITH DX COOLING | 0.301043 | 0.301043 | 0.301043 | 0.301043 | 6195.79 | 5898.42 | 1.00 |
SPLIT TSE FURNACE WITH DX COOLING | 0.304151 | 0.304151 | 0.304151 | 0.304151 | 6176.35 | 6019.55 | 1.00 |
SPLIT TNE FURNACE WITH DX COOLING | 0.250270 | 0.250270 | 0.250270 | 0.250270 | 6180.07 | 5164.63 | 1.00 |
SPLIT TN1 FURNACE WITH DX COOLING | 0.194593 | 0.194593 | 0.194593 | 0.194593 | 4672.09 | 4082.32 | 1.00 |
SPLIT TN2 FURNACE WITH DX COOLING | 0.194666 | 0.194666 | 0.194666 | 0.194666 | 4671.68 | 4083.77 | 1.00 |
SPLIT TS1 FURNACE WITH DX COOLING | 0.245433 | 0.245433 | 0.245433 | 0.245433 | 4666.85 | 4896.49 | 1.00 |
SPLIT TS2 FURNACE WITH DX COOLING | 0.246216 | 0.246216 | 0.246216 | 0.246216 | 4666.45 | 4908.88 | 1.00 |
Maximum Flow Rate [m3/s] | |
SPLIT GSW SUPPLY FAN | 0.172009 |
SPLIT GNW SUPPLY FAN | 0.164224 |
SPLIT OFFICE SUPPLY FAN | 0.473040 |
SPLIT GNE SUPPLY FAN | 0.121716 |
SPLIT GN1 SUPPLY FAN | 0.093460 |
SPLIT GN2 SUPPLY FAN | 0.092384 |
SPLIT GS1 SUPPLY FAN | 0.109527 |
SPLIT GS2 SUPPLY FAN | 0.112617 |
SPLIT MSW SUPPLY FAN | 0.476554 |
SPLIT MNW SUPPLY FAN | 0.451255 |
SPLIT MSE SUPPLY FAN | 0.431834 |
SPLIT MNE SUPPLY FAN | 0.358272 |
SPLIT MN1 SUPPLY FAN | 0.271487 |
SPLIT MN2 SUPPLY FAN | 0.269674 |
SPLIT MS1 SUPPLY FAN | 0.317714 |
SPLIT MS2 SUPPLY FAN | 0.318933 |
SPLIT TSW SUPPLY FAN | 0.327225 |
SPLIT TNW SUPPLY FAN | 0.301043 |
SPLIT TSE SUPPLY FAN | 0.304151 |
SPLIT TNE SUPPLY FAN | 0.250270 |
SPLIT TN1 SUPPLY FAN | 0.194593 |
SPLIT TN2 SUPPLY FAN | 0.194666 |
SPLIT TS1 SUPPLY FAN | 0.245433 |
SPLIT TS2 SUPPLY FAN | 0.246216 |
Nominal Capacity [W] | |
SPLIT GSW HEATING COIL | 4216.86 |
SPLIT GNW HEATING COIL | 4173.98 |
SPLIT OFFICE HEATING COIL | 6928.90 |
SPLIT GNE HEATING COIL | 4162.43 |
SPLIT GN1 HEATING COIL | 3123.07 |
SPLIT GN2 HEATING COIL | 3122.81 |
SPLIT GS1 HEATING COIL | 3122.83 |
SPLIT GS2 HEATING COIL | 3256.81 |
SPLIT MSW HEATING COIL | 8602.32 |
SPLIT MNW HEATING COIL | 8606.02 |
SPLIT MSE HEATING COIL | 8572.26 |
SPLIT MNE HEATING COIL | 8575.94 |
SPLIT MN1 HEATING COIL | 5907.26 |
SPLIT MN2 HEATING COIL | 5906.53 |
SPLIT MS1 HEATING COIL | 5905.97 |
SPLIT MS2 HEATING COIL | 5905.25 |
SPLIT TSW HEATING COIL | 6192.06 |
SPLIT TNW HEATING COIL | 6195.79 |
SPLIT TSE HEATING COIL | 6176.35 |
SPLIT TNE HEATING COIL | 6180.07 |
SPLIT TN1 HEATING COIL | 4672.09 |
SPLIT TN2 HEATING COIL | 4671.68 |
SPLIT TS1 HEATING COIL | 4666.85 |
SPLIT TS2 HEATING COIL | 4666.45 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:16
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
G SWALL SWA | GWINDOW1 S SWA | |
G WWALL SWA | GWINDOW1 W SWA | |
G NWALL NWA | GWINDOW1 N NWA | |
G WWALL NWA | GWINDOW1 W NWA | |
G SWALL SEA | GWINDOW1 S SEA | |
G EWALL SEA | GWINDOW1 E SEA | |
G NWALL NEA | GWINDOW1 N NEA | |
G EWALL NEA | GWINDOW1 E NEA | |
G NWALL N1A | GWINDOW1 N N1A | |
G NWALL N2A | GWINDOW1 N N2A | |
G SWALL S1A | GWINDOW1 S S1A | |
G SWALL S2A | GWINDOW1 S S2A | |
M WWALL SWA | MWINDOW1 W SWA | |
M SWALL SWA | MWINDOW1 S SWA | |
M NWALL NWA | MWINDOW1 N NWA | |
M WWALL NWA | MWINDOW1 W NWA | |
M EWALL SEA | MWINDOW1 E SEA | |
M SWALL SEA | MWINDOW1 S SEA | |
M NWALL NEA | MWINDOW1 N NEA | |
M EWALL NEA | MWINDOW1 E NEA | |
M NWALL N1A | MWINDOW1 N N1A | |
M NWALL N2A | MWINDOW1 N N2A | |
M SWALL S1A | MWINDOW1 S S1A | |
M SWALL S2A | MWINDOW1 S S2A | |
T WWALL SWA | TWINDOW1 W SWA | |
T SWALL SWA | TWINDOW1 S SWA | |
T NWALL NWA | TWINDOW1 N NWA | |
T WWALL NWA | TWINDOW1 W NWA | |
T EWALL SEA | TWINDOW1 E SEA | |
T SWALL SEA | TWINDOW1 S SEA | |
T NWALL NEA | TWINDOW1 N NEA | |
T EWALL NEA | TWINDOW1 E NEA | |
T NWALL N1A | TWINDOW1 N N1A | |
T NWALL N2A | TWINDOW1 N N2A | |
T SWALL S1A | TWINDOW1 S S1A | |
T SWALL S2A | TWINDOW1 S S2A | |
T EWALL C | TWINDOW14 | |
G EWALL C | ENTRANCE DOOR | |
M EWALL C | MWINDOW14 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2015-09-09 18:47:16
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: MONTHLY INDOOR TEMP
For: G SW APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.71 | -2.5 |
March | 21.80 | 3.82 |
April | 22.36 | 9.95 |
May | 22.99 | 15.31 |
June | 24.23 | 21.11 |
July | 24.39 | 24.13 |
August | 24.37 | 21.78 |
September | 24.18 | 18.14 |
October | 22.44 | 10.98 |
November | 21.88 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.82 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.39 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: G NW APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.72 | 3.82 |
April | 22.24 | 9.95 |
May | 22.87 | 15.31 |
June | 24.22 | 21.11 |
July | 24.39 | 24.13 |
August | 24.37 | 21.78 |
September | 24.10 | 18.14 |
October | 22.06 | 10.98 |
November | 21.79 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.74 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.39 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: OFFICE
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.05 | -4.6 |
February | 19.63 | -2.5 |
March | 21.11 | 3.82 |
April | 22.50 | 9.95 |
May | 24.08 | 15.31 |
June | 25.87 | 21.11 |
July | 26.70 | 24.13 |
August | 26.24 | 21.78 |
September | 25.80 | 18.14 |
October | 23.25 | 10.98 |
November | 21.28 | 4.73 |
December | 19.27 | -3.7 |
Annual Sum or Average | 22.91 | 9.99 |
Minimum of Months | 19.05 | -4.6 |
Maximum of Months | 26.70 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: G NE APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.71 | 3.82 |
April | 22.19 | 9.95 |
May | 22.81 | 15.31 |
June | 24.19 | 21.11 |
July | 24.38 | 24.13 |
August | 24.36 | 21.78 |
September | 24.07 | 18.14 |
October | 22.00 | 10.98 |
November | 21.77 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.72 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: G N1 APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.71 | 3.82 |
April | 22.15 | 9.95 |
May | 22.66 | 15.31 |
June | 24.20 | 21.11 |
July | 24.38 | 24.13 |
August | 24.36 | 21.78 |
September | 24.10 | 18.14 |
October | 22.01 | 10.98 |
November | 21.78 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.71 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: G N2 APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.71 | 3.82 |
April | 22.14 | 9.95 |
May | 22.66 | 15.31 |
June | 24.19 | 21.11 |
July | 24.38 | 24.13 |
August | 24.36 | 21.78 |
September | 24.10 | 18.14 |
October | 22.00 | 10.98 |
November | 21.78 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.71 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.38 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: G S1 APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -4.6 |
February | 21.71 | -2.5 |
March | 21.79 | 3.82 |
April | 22.30 | 9.95 |
May | 22.87 | 15.31 |
June | 24.23 | 21.11 |
July | 24.39 | 24.13 |
August | 24.37 | 21.78 |
September | 24.23 | 18.14 |
October | 22.50 | 10.98 |
November | 21.91 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.81 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.39 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: G S2 APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.71 | -4.6 |
February | 21.71 | -2.5 |
March | 21.79 | 3.82 |
April | 22.31 | 9.95 |
May | 22.90 | 15.31 |
June | 24.25 | 21.11 |
July | 24.39 | 24.13 |
August | 24.38 | 21.78 |
September | 24.25 | 18.14 |
October | 22.53 | 10.98 |
November | 21.93 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.83 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.39 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: M SW APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.73 | -4.6 |
February | 21.77 | -2.5 |
March | 22.14 | 3.82 |
April | 22.90 | 9.95 |
May | 24.25 | 15.31 |
June | 24.39 | 21.11 |
July | 24.40 | 24.13 |
August | 24.40 | 21.78 |
September | 24.38 | 18.14 |
October | 23.65 | 10.98 |
November | 22.51 | 4.73 |
December | 21.72 | -3.7 |
Annual Sum or Average | 23.20 | 9.99 |
Minimum of Months | 21.72 | -4.6 |
Maximum of Months | 24.40 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: M NW APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.71 | -2.5 |
March | 21.81 | 3.82 |
April | 22.67 | 9.95 |
May | 24.19 | 15.31 |
June | 24.39 | 21.11 |
July | 24.40 | 24.13 |
August | 24.40 | 21.78 |
September | 24.35 | 18.14 |
October | 22.90 | 10.98 |
November | 22.29 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 23.05 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.40 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: M SE APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.73 | -4.6 |
February | 21.76 | -2.5 |
March | 22.13 | 3.82 |
April | 22.86 | 9.95 |
May | 24.25 | 15.31 |
June | 24.39 | 21.11 |
July | 24.40 | 24.13 |
August | 24.40 | 21.78 |
September | 24.38 | 18.14 |
October | 23.65 | 10.98 |
November | 22.48 | 4.73 |
December | 21.71 | -3.7 |
Annual Sum or Average | 23.19 | 9.99 |
Minimum of Months | 21.71 | -4.6 |
Maximum of Months | 24.40 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: M NE APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.77 | 3.82 |
April | 22.60 | 9.95 |
May | 24.15 | 15.31 |
June | 24.38 | 21.11 |
July | 24.40 | 24.13 |
August | 24.40 | 21.78 |
September | 24.34 | 18.14 |
October | 22.83 | 10.98 |
November | 22.22 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 23.02 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.40 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: M N1 APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.71 | -2.5 |
March | 21.82 | 3.82 |
April | 22.64 | 9.95 |
May | 24.23 | 15.31 |
June | 24.39 | 21.11 |
July | 24.40 | 24.13 |
August | 24.40 | 21.78 |
September | 24.38 | 18.14 |
October | 23.09 | 10.98 |
November | 22.38 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 23.08 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.40 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: M N2 APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.71 | -2.5 |
March | 21.82 | 3.82 |
April | 22.64 | 9.95 |
May | 24.22 | 15.31 |
June | 24.39 | 21.11 |
July | 24.40 | 24.13 |
August | 24.40 | 21.78 |
September | 24.38 | 18.14 |
October | 23.09 | 10.98 |
November | 22.37 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 23.07 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.40 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: M S1 APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.77 | -4.6 |
February | 21.82 | -2.5 |
March | 22.29 | 3.82 |
April | 23.00 | 9.95 |
May | 24.31 | 15.31 |
June | 24.39 | 21.11 |
July | 24.40 | 24.13 |
August | 24.40 | 21.78 |
September | 24.40 | 18.14 |
October | 23.98 | 10.98 |
November | 22.66 | 4.73 |
December | 21.74 | -3.7 |
Annual Sum or Average | 23.27 | 9.99 |
Minimum of Months | 21.74 | -4.6 |
Maximum of Months | 24.40 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: M S2 APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.77 | -4.6 |
February | 21.82 | -2.5 |
March | 22.29 | 3.82 |
April | 23.00 | 9.95 |
May | 24.31 | 15.31 |
June | 24.39 | 21.11 |
July | 24.40 | 24.13 |
August | 24.40 | 21.78 |
September | 24.40 | 18.14 |
October | 23.98 | 10.98 |
November | 22.66 | 4.73 |
December | 21.74 | -3.7 |
Annual Sum or Average | 23.27 | 9.99 |
Minimum of Months | 21.74 | -4.6 |
Maximum of Months | 24.40 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: T SW APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.73 | -4.6 |
February | 21.76 | -2.5 |
March | 22.04 | 3.82 |
April | 22.74 | 9.95 |
May | 23.78 | 15.31 |
June | 24.28 | 21.11 |
July | 24.39 | 24.13 |
August | 24.38 | 21.78 |
September | 24.13 | 18.14 |
October | 22.93 | 10.98 |
November | 22.16 | 4.73 |
December | 21.71 | -3.7 |
Annual Sum or Average | 23.01 | 9.99 |
Minimum of Months | 21.71 | -4.6 |
Maximum of Months | 24.39 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: T NW APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.71 | -2.5 |
March | 21.81 | 3.82 |
April | 22.60 | 9.95 |
May | 23.68 | 15.31 |
June | 24.26 | 21.11 |
July | 24.39 | 24.13 |
August | 24.37 | 21.78 |
September | 24.02 | 18.14 |
October | 22.45 | 10.98 |
November | 22.00 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.90 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.39 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: T SE APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.72 | -4.6 |
February | 21.75 | -2.5 |
March | 22.04 | 3.82 |
April | 22.73 | 9.95 |
May | 23.78 | 15.31 |
June | 24.27 | 21.11 |
July | 24.39 | 24.13 |
August | 24.38 | 21.78 |
September | 24.13 | 18.14 |
October | 22.93 | 10.98 |
November | 22.13 | 4.73 |
December | 21.71 | -3.7 |
Annual Sum or Average | 23.00 | 9.99 |
Minimum of Months | 21.71 | -4.6 |
Maximum of Months | 24.39 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: T NE APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.78 | 3.82 |
April | 22.56 | 9.95 |
May | 23.66 | 15.31 |
June | 24.24 | 21.11 |
July | 24.39 | 24.13 |
August | 24.36 | 21.78 |
September | 24.00 | 18.14 |
October | 22.38 | 10.98 |
November | 21.95 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.87 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.39 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: T N1 APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.79 | 3.82 |
April | 22.56 | 9.95 |
May | 23.70 | 15.31 |
June | 24.29 | 21.11 |
July | 24.39 | 24.13 |
August | 24.37 | 21.78 |
September | 24.06 | 18.14 |
October | 22.47 | 10.98 |
November | 22.04 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.90 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.39 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: T N2 APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.70 | -4.6 |
February | 21.70 | -2.5 |
March | 21.79 | 3.82 |
April | 22.56 | 9.95 |
May | 23.70 | 15.31 |
June | 24.28 | 21.11 |
July | 24.39 | 24.13 |
August | 24.37 | 21.78 |
September | 24.06 | 18.14 |
October | 22.47 | 10.98 |
November | 22.04 | 4.73 |
December | 21.70 | -3.7 |
Annual Sum or Average | 22.90 | 9.99 |
Minimum of Months | 21.70 | -4.6 |
Maximum of Months | 24.39 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: T S1 APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.75 | -4.6 |
February | 21.78 | -2.5 |
March | 22.12 | 3.82 |
April | 22.78 | 9.95 |
May | 23.87 | 15.31 |
June | 24.32 | 21.11 |
July | 24.40 | 24.13 |
August | 24.38 | 21.78 |
September | 24.21 | 18.14 |
October | 23.12 | 10.98 |
November | 22.29 | 4.73 |
December | 21.72 | -3.7 |
Annual Sum or Average | 23.07 | 9.99 |
Minimum of Months | 21.72 | -4.6 |
Maximum of Months | 24.40 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: T S2 APARTMENT
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.75 | -4.6 |
February | 21.78 | -2.5 |
March | 22.13 | 3.82 |
April | 22.78 | 9.95 |
May | 23.87 | 15.31 |
June | 24.32 | 21.11 |
July | 24.40 | 24.13 |
August | 24.38 | 21.78 |
September | 24.21 | 18.14 |
October | 23.12 | 10.98 |
November | 22.29 | 4.73 |
December | 21.72 | -3.7 |
Annual Sum or Average | 23.07 | 9.99 |
Minimum of Months | 21.72 | -4.6 |
Maximum of Months | 24.40 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: T CORRIDOR
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.32 | -4.6 |
February | 20.69 | -2.5 |
March | 21.79 | 3.82 |
April | 23.36 | 9.95 |
May | 25.27 | 15.31 |
June | 26.45 | 21.11 |
July | 26.92 | 24.13 |
August | 26.56 | 21.78 |
September | 25.82 | 18.14 |
October | 23.50 | 10.98 |
November | 21.90 | 4.73 |
December | 20.44 | -3.7 |
Annual Sum or Average | 23.60 | 9.99 |
Minimum of Months | 20.32 | -4.6 |
Maximum of Months | 26.92 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: G CORRIDOR
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 17.48 | -4.6 |
February | 17.96 | -2.5 |
March | 19.39 | 3.82 |
April | 21.01 | 9.95 |
May | 22.80 | 15.31 |
June | 25.46 | 21.11 |
July | 26.36 | 24.13 |
August | 25.85 | 21.78 |
September | 24.95 | 18.14 |
October | 21.62 | 10.98 |
November | 19.71 | 4.73 |
December | 17.74 | -3.7 |
Annual Sum or Average | 21.71 | 9.99 |
Minimum of Months | 17.48 | -4.6 |
Maximum of Months | 26.36 | 24.13 |
Report: MONTHLY INDOOR TEMP
For: M CORRIDOR
Timestamp: 2015-09-09 18:47:16
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.42 | -4.6 |
February | 22.65 | -2.5 |
March | 23.36 | 3.82 |
April | 24.46 | 9.95 |
May | 26.26 | 15.31 |
June | 26.74 | 21.11 |
July | 26.92 | 24.13 |
August | 26.77 | 21.78 |
September | 26.55 | 18.14 |
October | 25.16 | 10.98 |
November | 23.73 | 4.73 |
December | 22.48 | -3.7 |
Annual Sum or Average | 24.80 | 9.99 |
Minimum of Months | 22.42 | -4.6 |
Maximum of Months | 26.92 | 24.13 |
Report: PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2015-09-09 18:47:16
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [Invalid/Undefined] | HEATREJECTION:ELECTRICITY [Invalid/Undefined] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY {AT MAX/MIN} [W] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined] | |
January | 0.116626E+12 | 73757.197 | 20-JAN-18:00 | 4979.953 | 26630.920 | 7311.308 | 0.000 | 0.000 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32282.015 | 0.000 | 0.000 | 0.000 |
February | 0.105516E+12 | 71900.514 | 21-FEB-18:45 | 4979.953 | 26630.920 | 7311.308 | 0.000 | 0.000 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 30425.332 | 0.000 | 0.000 | 0.000 |
March | 0.116087E+12 | 72005.055 | 05-MAR-18:15 | 4979.953 | 26630.920 | 7311.308 | 0.000 | 0.000 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 30529.873 | 0.000 | 0.000 | 0.000 |
April | 0.115299E+12 | 79871.500 | 15-APR-17:45 | 4979.953 | 26630.920 | 7311.308 | 0.000 | 16268.299 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 24681.019 | 0.000 | 0.000 | 0.000 |
May | 0.120602E+12 | 79553.476 | 30-MAY-17:45 | 4979.953 | 26630.920 | 7311.308 | 0.000 | 17080.711 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23550.582 | 0.000 | 0.000 | 0.000 |
June | 0.127535E+12 | 83285.733 | 27-JUN-17:15 | 4979.953 | 26630.920 | 7311.308 | 0.000 | 18661.807 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 25701.744 | 0.000 | 0.000 | 0.000 |
July | 0.142572E+12 | 89053.588 | 16-JUL-17:00 | 4979.953 | 26630.920 | 7311.308 | 0.000 | 25197.417 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 24933.989 | 0.000 | 0.000 | 0.000 |
August | 0.133782E+12 | 86931.828 | 04-AUG-17:15 | 4979.953 | 26630.920 | 7311.308 | 0.000 | 24615.474 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23394.173 | 0.000 | 0.000 | 0.000 |
September | 0.119494E+12 | 78035.777 | 09-SEP-17:15 | 4979.953 | 26630.920 | 7311.308 | 0.000 | 11738.081 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 27375.514 | 0.000 | 0.000 | 0.000 |
October | 0.112478E+12 | 70081.601 | 21-OCT-17:15 | 4979.953 | 26630.920 | 7311.308 | 0.000 | 4932.987 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23673.433 | 0.000 | 0.000 | 0.000 |
November | 0.109773E+12 | 70208.735 | 03-NOV-17:15 | 4979.953 | 26630.920 | 7311.308 | 0.000 | 4083.095 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 24650.457 | 0.000 | 0.000 | 0.000 |
December | 0.115104E+12 | 71076.535 | 14-DEC-18:45 | 4979.953 | 26630.920 | 7311.308 | 0.000 | 0.000 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 29601.353 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.143487E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||
Minimum of Months | 0.105516E+12 | 70081.601 | 4979.953 | 26630.920 | 7311.308 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 23394.173 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.142572E+12 | 89053.588 | 4979.953 | 26630.920 | 7311.308 | 0.000 | 25197.417 | 2553.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 32282.015 | 0.000 | 0.000 | 0.000 |
Report: PEAK GAS DEMAND
For: Meter
Timestamp: 2015-09-09 18:47:16
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC {AT MAX/MIN} [W] | INTERIOREQUIPMENT:GAS [Invalid/Undefined] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT [Invalid/Undefined] | WATERSYSTEMS:GAS [Invalid/Undefined] | WATER HEATER:WATERSYSTEMS:GAS [Invalid/Undefined] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.151971E+12 | 159144.106 | 27-JAN-00:00 | 159144.106 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 159144.106 |
February | 0.113195E+12 | 110445.315 | 06-FEB-04:00 | 110445.315 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 110445.315 |
March | 0.668911E+11 | 100697.455 | 05-MAR-04:00 | 100697.455 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 100697.455 |
April | 0.280554E+11 | 56114.040 | 01-APR-00:15 | 56114.040 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 56114.040 |
May | 0.164723E+10 | 13017.077 | 09-MAY-02:00 | 13017.077 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 13017.077 |
June | 517019.243 | 319.420 | 25-JUN-04:15 | 319.420 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 319.420 |
July | 0.000 | 0.000 | 01-JUL-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.000 | 0.000 | 01-AUG-00:15 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.132330E+08 | 620.499 | 21-SEP-04:00 | 620.499 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 620.499 |
October | 0.105076E+11 | 30580.051 | 17-OCT-03:00 | 30580.051 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 30580.051 |
November | 0.672244E+11 | 116287.659 | 25-NOV-22:00 | 116287.659 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 116287.659 |
December | 0.135475E+12 | 120199.082 | 20-DEC-20:00 | 120199.082 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 120199.082 |
Annual Sum or Average | 0.574980E+12 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | ||||
Minimum of Months | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.151971E+12 | 159144.106 | 159144.106 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 159144.106 |